WorldWideScience

Sample records for three-dimensional ct study

  1. Study of three-dimensional image display by systemic CT

    International Nuclear Information System (INIS)

    Fujioka, Tadao; Ebihara, Yoshiyuki; Unei, Hiroshi; Hayashi, Masao; Shinohe, Tooru; Wada, Yuji; Sakai, Takatsugu; Kashima, Kenji; Fujita, Yoshihiro

    1989-01-01

    A head phantom for CT was scanned at 2 mm intervals from the cervix to the vertex in an attempt to obtain a three-dimensional image display of bones and facial epidermis from an ordinary axial image. Clinically, three-dimensional images were formed at eye sockets and hip joints. With the three-dimensional image using the head phantom, the entire head could be displayed at any angle. Clinically, images were obtained that could not be attained by ordinary CT scanning, such as broken bones in eye sockets and stereoscopic structure at the bottom of a cranium. The three-dimensional image display is considered to be useful in clinical diagnosis. (author)

  2. Three dimensional CT imaging of ossicular chain: a preliminary study

    International Nuclear Information System (INIS)

    Hu Chunhong; Zhong Shenbin; Fu Yindi; Zhu Wei; Wang Xueyuan; Chen Jianhua; Ding Yi

    2001-01-01

    Objective: To analysis the features of normal and abnormal ossicular chain in three dimensional images and asses the best parameters and its usefulness in diagnosis and treatment of chronic otitis media (COM). Methods: All patients, including 43 patients with normal ears and 24 ears with COM, were examined using spiral CT with inner ear software, 1-mm slice width and 1 pitch. SSD method was used in three dimensional reconstruction and the threshold was 100-300 Hu. Results: In normal cases, Malleus, incus, stapes crura, incudomalleal joints and incudostapedial joints were displayed well, but stapes footplate unsatisfactorily. The disruption of the ossicular chain showed in three-dimensional images in cases of chronic otitis media was in accord with that seen in the operation. Conclusion: It is very important for imaging with high quality through selecting proper parameters, and three-dimensional image can provide valuable information for surgery

  3. A pilot study of three dimensional color CT images of brain diseases to improve informed consent

    International Nuclear Information System (INIS)

    Tanizaki, Yoshio; Akiyama, Takenori; Hiraga, Kenji; Akaji, Kazunori

    2005-01-01

    We have described brain diseases to patients and their family using monochrome CT images. It is thought that patients have difficulties in giving their consent to our conventional explanation because their understanding of brain diseases is based on three dimensional and color images, however, standard CT images are two dimensional and gray scale images. We have been trying to use three dimensional color CT images to improve the typical patient's comprehension of brain diseases. We also try to simulate surgery using these images. Multi-slice CT accumulates precise isotropic voxel data within a half minute. These two dimensional and monochrome data are converted to three dimensional color CT images by 3D workstation. Three dimensional color CT images of each brain structures (e.g. scalp, skull, brain, ventricles and lesions) are created separately. Then, selected structures are fused together for different purposes. These images are able to rotate around any axis. Because the methods to generate three-dimensional color images have not established, we neurosurgeons must create these images. In particular, when an operation is required, the surgeon should create the images. In this paper, we demonstrate how three-dimensional color CT images can improve informed consent. (author)

  4. Postoperative follow-up study of craniosynostosis using three-dimensional surface reconstruction CT (3D-CT)

    Energy Technology Data Exchange (ETDEWEB)

    Nishimoto, Hiroshi; Tsukiyama, Takashi; Nishimura, Jiro; Fujioka, Mutsuhisa; Tsubokawa, Takashi.

    1988-12-01

    In 1983, Michael W. Vannier and Jeffrey L. Marsh developed a computer method that reconstructs three-dimensional images from high-resolution CT-scan series of the facial skeleton. This method has been applied to craniofacial anomalies, basal encephalocele, and other skeletal pathologies. In this study, the postoperative assessment of craniofacial surgical results has been accomplished using 3D-CT techniques in craniosynostosis. The results are as follows: (1) Postoperative 3D-CTs reveal the bony anatomical details corrected by the craniofacial surgery more precisely and more stereographically than do conventional radiological techniques. (2) Secondary changes in the cranium after the surgery, such as reossification at the area of osteotomies or postoperative asymmetric skull deformities, are more early detected by the 3D-CT imaging technique than by a craniogram. (3) In 3D-CT images, internal views of the skull, such mid-sagittal, rear internal, or top axial views of the intracranial skull base, are most useful in postoperative assessments of the surgical results and of postoperative secondary changes in the cranium. Based on our experience, we expect that 3D-CT imaging techniques will become more important in the management of craniosynostosis.

  5. Postoperative follow-up study of craniosynostosis using three-dimensional surface reconstruction CT (3D-CT)

    International Nuclear Information System (INIS)

    Nishimoto, Hiroshi; Tsukiyama, Takashi; Nishimura, Jiro; Fujioka, Mutsuhisa; Tsubokawa, Takashi.

    1988-01-01

    In 1983, Michael W. Vannier and Jeffrey L. Marsh developed a computer method that reconstructs three-dimensional images from high-resolution CT-scan series of the facial skeleton. This method has been applied to craniofacial anomalies, basal encephalocele, and other skeletal pathologies. In this study, the postoperative assessment of craniofacial surgical results has been accomplished using 3D-CT techniques in craniosynostosis. The results are as follows: 1) Postoperative 3D-CTs reveal the bony anatomical details corrected by the craniofacial surgery more precisely and more stereographically than do conventional radiological techniques. 2) Secondary changes in the cranium after the surgery, such as reossification at the area of osteotomies or postoperative asymmetric skull deformities, are more early detected by the 3D-CT imaging technique than by a craniogram. 3) In 3D-CT images, internal views of the skull, such mid-sagittal, rear internal, or top axial views of the intracranial skull base, are most useful in postoperative assessments of the surgical results and of postoperative secondary changes in the cranium. Based on our experience, we expect that 3D-CT imaging techniques will become more important in the management of craniosynostosis. (author)

  6. Morphometric analysis of acetabular dysplasia in cerebral palsy: three-dimensional CT study.

    Science.gov (United States)

    Gose, Shinichi; Sakai, Takashi; Shibata, Toru; Murase, Tsuyoshi; Yoshikawa, Hideki; Sugamoto, Kazuomi

    2009-12-01

    Three-dimensional computed tomography (3D-CT) eliminates the positioning errors and allows the clinician to more accurately assess the radiographic parameters present. To elucidate the 3D geometry of the acetabulum and the extent of hip subluxation/dislocation in patients with cerebral palsy (CP), quantitative morphometric analysis was performed using 3D-CT data. We evaluated 150 hips in 75 patients with bilateral spastic CP. The mean age of the patients was 5.4 years (range: 2.7 to 6.9 y). The fitting plane of the ilium was projected onto the coronal plane and then onto the sagittal plane, and then the angle formed with a horizontal line was defined as CTalpha (the lateral opening angle) and CTbeta (the sagittal inclination angle), respectively. The center of the acetabulum and the femoral head were defined, and the distance between these centers was divided by the femoral head diameter, defined as CT migration percentage (CTMP, %). In 123 (82%) of the 150 hips, the femoral head center was located posteriorly, superiorly, and laterally relative to the acetabular center. Large CTalpha cases tended to show large CTMP. CTalpha and CTMP were significantly larger in the cases with Gross Motor Functional Classification System (GMFCS) level IV/V and spastic quadriplegia, than in the cases with GMFCS level II/III and spastic diplegia. CTbeta showed significant correlation with the acetabular defect on the lateral 3D reconstructed images. Three-dimensional acetabular geometry and migration percentage in CP patients can be analyzed quantitatively using 3D-CT regardless of the abnormal spastic posture. The extent of acetabular dysplasia and subluxation is more severe in patients with GMFCS level IV/V and spastic quadriplesia. Level 4.

  7. Panoramic three-dimensional CT imaging

    International Nuclear Information System (INIS)

    Kawamata, Akitoshi; Fujishita, Masami

    1998-01-01

    Panoramic radiography is a unique projection technique for producing a single image of both maxillary and mandibular arches and many other anatomical structures. To obtain a similar panoramic image without panoramic radiography system, a modified three-dimensional (3D) CT imaging technique was designed. A set of CT slice image data extending from the chin to the orbit was used for 3D reconstruction. The CT machine used in this study was the X-Vision (TOSHIBA, Japan). The helical scan technique was used. The slice thickness of reconstructed image was one or 1.5 mm. The occlusal plane or Frankfort horizontal (FH) plane was used as the reference line. The resultant slice image data was stored on a magnetic optical disk and then used to create panoramic 3D-CT images on a Macintosh computer systems (Power Macintosh 8600/250, Apple Computer Inc., USA). To create the panoramic 3D-CT image, the following procedure was designed: Design a curved panoramic 3D-CT imaging layer using the imaging layer and the movement of the x-ray beam in panoramic radiography system as a template; Cut this imaging layer from each slice image, then the trimmed image was transformed to a rectangular layer using the ''still image warping'' special effect in the Elastic Reality special effects system (Elastic Reality Inc., USA); Create panoramic 3D-CT image using the Voxel View (Vital Images Inc., USA) rendering system and volume rendering technique. Although the image quality was primitive, a panoramic view of maxillofacial region was obtained by this technique. (author)

  8. Evaluation of gastric carcinoma with CT three-dimensional imaging compared with conventional barium study

    International Nuclear Information System (INIS)

    Ju Shenghong; Chen Feng; Zheng Kai'er; Sun Jun

    2002-01-01

    Objective: To assess the role of three-dimensional (3D) CT imaging including CT virtual gastroscopy (CTVG), surface-shaded display (SSD), and Raysum Display in the evaluation of gastric carcinoma compared with upper gastrointestinal series (UGI). Methods: In 43 histologically proved gastric carcinoma patients (37 advanced gastric carcinomas and 6 early gastric carcinomas), the results of CTVG and 3D CT imaging were compared to that of UGI. Two observers blindly evaluated images with all four techniques in terms of image quality, artifacts, diagnostic confidence, and Borrmann classification. Sensitivities of lesion detection and classification based on Borrmann classification of CTVG and 3D CT were determined by comparing them to surgical and histological findings. Results: The lesion detection sensitivity of CTVG, SSD, Raysum, and UGI by two observers were 98%, 67%, 60% and 84%, and 98%, 70%, 70% and 88%, respectively. The Borrmann's classification sensitivity by two observers were 76%, 49%, 38% and 49%, and 78%, 51%, 35% and 43%, respectively. Overall image quality of CTVG, SSD, and Raysum was considered similar to that of UGI by both observers (P>0.05). There was no statistical significant difference for advanced lesion (with diagnostic confidence of 3 or above) in detection sensitivity between CTVG and UGI (χ 2 = 0.50 and 0.25, P>0.05), but the lesion detection sensitivity of SSD and Raysum display were lower than that of UGI (χ 2 4.17, 7.11 and 5.14, 4.17, P 2 = 4.90 and 4.92, P 2 = 2.25, P > 0.05). Excess fluid remained in the stomach and patient respiratory movement during breath holds were the reasons causing severe artifacts (6.1%) that influenced the diagnostic evaluation. Conclusion: The performance of CTVG was equivalent to UGI in the Borrmann's classification. CTVG has potential in the detection of early gastric carcinoma. The value of SSD and Raysum display was limited in the evaluation of gastric carcinoma when used alone clinically

  9. Two- and three-dimensional CT analysis of ankle fractures

    International Nuclear Information System (INIS)

    Magid, D.; Fishman, E.K.; Ney, D.R.; Kuhlman, J.E.

    1988-01-01

    CT with coronal and sagittal reformatting (two-dimensional CT) and animated volumetric image rendering (three-dimensional CT) was used to assess ankle fractures. Partial volume limits transaxial CT in assessments of horizontally oriented structures. Two-dimensional CT, being orthogonal to the plafond, superior mortise, talar dome, and tibial epiphysis, often provides the most clinically useful images. Two-dimensional CT is most useful in characterizing potentially confusing fractures, such as Tillaux (anterior tubercle), triplane, osteochondral talar dome, or nondisplaced talar neck fractures, and it is the best study to confirm intraarticular fragments. Two-and three-dimensional CT best indicate the percentage of articular surface involvement and best demonstrate postoperative results or complications (hardware migration, residual step-off, delayed union, DJD, AVN, etc). Animated three-dimensional images are the preferred means of integrating the two-dimensional findings for surgical planning, as these images more closely simulate the clinical problem

  10. Three-dimensional CT of the mandible

    International Nuclear Information System (INIS)

    Zinreich, S.J.; Price, J.C.; Wang, H.; Ahn, H.S.; Kashima, H.

    1988-01-01

    Seventeen patients with mandibular oblation for facial neoplasia, primary neoplasm, and trauma were evaluated with CT and three-dimensional CT. In eight of these patients, a computerized acrylic model was generated for preoperative planning and postoperative reconstruction. The ramus and body of the mandible were reconstructed with mirror image and fusion techniques. Reconstructions of the anterior mandible were generated from models including the midface, skull based, and residual mandibular fragments. The results are preliminary; however, the authors believe that these represent a powerful new tool and a significant advance in mandibular reconstructive technique, reduced anesthesia time, and the optimized restoration of dental alignment and facial contour

  11. Three-dimensional reconstruction of CT images

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Toshiaki; Kattoh, Keiichi; Kawakami, Genichiroh; Igami, Isao; Mariya, Yasushi; Nakamura, Yasuhiko; Saitoh, Yohko; Tamura, Koreroku; Shinozaki, Tatsuyo

    1986-09-01

    Computed tomography (CT) has the ability to provide sensitive visualization of organs and lesions. Owing to the nature of CT to be transaxial images, a structure which is greater than a certain size appears as several serial CT images. Consequently each observer must reconstruct those images into a three-dimensional (3-D) form mentally. It has been supposed to be of great use if such a 3-D form can be described as a definite figure. A new computer program has been developed which can produce 3-D figures from the profiles of organs and lesions on CT images using spline curves. The figures obtained through this method are regarded to have practical applications.

  12. Application of Simulated Three Dimensional CT Image in Orthognathic Surgery

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Don; Park, Chang Seo [Dept. of Dental Radiology, College of Dentistry, Yensei University, Seoul (Korea, Republic of); Yoo, Sun Kook; Lee, Kyoung Sang [Dept. of Medical Engineering, College of Medicine, Yensei University, Seoul (Korea, Republic of)

    1998-08-15

    In orthodontics and orthognathic surgery, cephalogram has been routine practice in diagnosis and treatment evaluation of craniofacial deformity. But its inherent distortion of actual length and angles during projecting three dimensional object to two dimensional plane might cause errors in quantitative analysis of shape and size. Therefore, it is desirable that three dimensional object is diagnosed and evaluated three dimensionally and three dimensional CT image is best for three dimensional analysis. Development of clinic necessitates evaluation of result of treatment and comparison before and after surgery. It is desirable that patient that was diagnosed and planned by three dimensional computed tomography before surgery is evaluated by three dimensional computed tomography after surgery, too. But Because there is no standardized normal values in three dimension now and three dimensional Computed Tomography needs expensive equipment and because of its expenses and amount of exposure to radiation, limitations still remain to be solved in its application to routine practice. If postoperative three dimensional image is constructed by pre and postoperative lateral and postero-anterior cephalograms and preoperative three dimensional computed tomogram, pre and postoperative image will be compared and evaluated three dimensionally without three dimensional computed tomography after surgery and that will contribute to standardize normal values in three dimension. This study introduced new method that computer-simulated three dimensional image was constructed by preoperative three dimensional computed tomogram and pre and postoperative lateral and postero-anterior cephalograms, and for validation of new method, in four cases of dry skull that position of mandible was displaced and four patients of orthognathic surgery, computer-simulated three dimensional image and actual postoperative three dimensional image were compared. The results were as follows. 1. In four cases of

  13. Application of Simulated Three Dimensional CT Image in Orthognathic Surgery

    International Nuclear Information System (INIS)

    Kim, Hyun Don; Park, Chang Seo; Yoo, Sun Kook; Lee, Kyoung Sang

    1998-01-01

    In orthodontics and orthognathic surgery, cephalogram has been routine practice in diagnosis and treatment evaluation of craniofacial deformity. But its inherent distortion of actual length and angles during projecting three dimensional object to two dimensional plane might cause errors in quantitative analysis of shape and size. Therefore, it is desirable that three dimensional object is diagnosed and evaluated three dimensionally and three dimensional CT image is best for three dimensional analysis. Development of clinic necessitates evaluation of result of treatment and comparison before and after surgery. It is desirable that patient that was diagnosed and planned by three dimensional computed tomography before surgery is evaluated by three dimensional computed tomography after surgery, too. But Because there is no standardized normal values in three dimension now and three dimensional Computed Tomography needs expensive equipment and because of its expenses and amount of exposure to radiation, limitations still remain to be solved in its application to routine practice. If postoperative three dimensional image is constructed by pre and postoperative lateral and postero-anterior cephalograms and preoperative three dimensional computed tomogram, pre and postoperative image will be compared and evaluated three dimensionally without three dimensional computed tomography after surgery and that will contribute to standardize normal values in three dimension. This study introduced new method that computer-simulated three dimensional image was constructed by preoperative three dimensional computed tomogram and pre and postoperative lateral and postero-anterior cephalograms, and for validation of new method, in four cases of dry skull that position of mandible was displaced and four patients of orthognathic surgery, computer-simulated three dimensional image and actual postoperative three dimensional image were compared. The results were as follows. 1. In four cases of

  14. Three-dimensional CT of the pediatric spine

    International Nuclear Information System (INIS)

    Starshak, R.J.; Crawford, C.R.; Waisman, R.C.; Sty, J.R.

    1987-01-01

    CT of the spine has been shown to be useful in evaluating congenital, neoplastic, inflammatory, and traumatic lesions. Any portion of the neural arch may be involved by these disease processes. However, the complex nature of the spinal column can make evaluation of these abnormalities difficult on axial CT. This is especially true if the spine is distorted by scoliosis, kyphosis, or lordosis. The principal advantage of three-dimensional CT is its ability to display the surface relationships of complicated objects. The complexity of the spinal axis makes it ideal for study with three-dimensional CT. This presentation illustrates the advantages and drawbacks of three-dimensional CT in spinal abnormalities in children

  15. Accuracy and Precision of Three-Dimensional Low Dose CT Compared to Standard RSA in Acetabular Cups: An Experimental Study.

    Science.gov (United States)

    Brodén, Cyrus; Olivecrona, Henrik; Maguire, Gerald Q; Noz, Marilyn E; Zeleznik, Michael P; Sköldenberg, Olof

    2016-01-01

    Background and Purpose. The gold standard for detection of implant wear and migration is currently radiostereometry (RSA). The purpose of this study is to compare a three-dimensional computed tomography technique (3D CT) to standard RSA as an alternative technique for measuring migration of acetabular cups in total hip arthroplasty. Materials and Methods. With tantalum beads, we marked one cemented and one uncemented cup and mounted these on a similarly marked pelvic model. A comparison was made between 3D CT and standard RSA for measuring migration. Twelve repeated stereoradiographs and CT scans with double examinations in each position and gradual migration of the implants were made. Precision and accuracy of the 3D CT were calculated. Results. The accuracy of the 3D CT ranged between 0.07 and 0.32 mm for translations and 0.21 and 0.82° for rotation. The precision ranged between 0.01 and 0.09 mm for translations and 0.06 and 0.29° for rotations, respectively. For standard RSA, the precision ranged between 0.04 and 0.09 mm for translations and 0.08 and 0.32° for rotations, respectively. There was no significant difference in precision between 3D CT and standard RSA. The effective radiation dose of the 3D CT method, comparable to RSA, was estimated to be 0.33 mSv. Interpretation. Low dose 3D CT is a comparable method to standard RSA in an experimental setting.

  16. Contrast agent comparison for three-dimensional micro-CT angiography: A cadaveric study.

    Science.gov (United States)

    Kingston, Mitchell J; Perriman, Diana M; Neeman, Teresa; Smith, Paul N; Webb, Alexandra L

    2016-07-01

    Barium sulfate and lead oxide contrast media are frequently used for cadaver-based angiography studies. These contrast media have not previously been compared to determine which is optimal for the visualisation and measurement of blood vessels. In this study, the lower limb vessels of 16 embalmed Wistar rats, and four sets of cannulae of known diameter, were injected with one of three different contrast agents (barium sulfate and resin, barium sulfate and gelatin, and lead oxide combined with milk powder). All were then scanned using micro-computed tomography (CT) angiography and 3-D reconstructions generated. The number of branching generations of the rat lower limb vessels were counted and compared between the contrast agents using ANOVA. The diameter of the contrast-filled cannulae, were measured and used to calculate the accuracy of the measurements by comparing the bias and variance of the estimates. Intra- and inter-observer reliability were calculated using intra-class correlation coefficients. There was no significant difference (mean difference [MD] 0.05; MD 95% confidence interval [CI] -0.83 to 0.93) between the number of branching generations for barium sulfate-resin and lead oxide-milk powder. Barium sulfate-resin demonstrated less bias and less variance of the estimates (MD 0.03; standard deviation [SD] 1.96 mm) compared to lead oxide-milk powder (MD 0.11; SD 1.96 mm) for measurements of contrast-filled cannulae scanned at high resolution. Barium sulfate-resin proved to be more accurate than lead oxide-milk powder for high resolution micro-CT scans and is preferred due to its non-toxicity. This technique could be applied to any embalmed specimen model. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  17. The study on three-dimensional measurement of the Human Eustachian tube examined by Multislice CT

    International Nuclear Information System (INIS)

    Yoshioka, Satoshi; Naito, Kensei; Fujii, Naoko; Katada, Kazuhiro; Takeuchi, Kenji

    2007-01-01

    Morphological aberration of the Eustachian tube is a significant factor of various middle ear diseases. Traditionally, cadaveric specimens have been used for studies on the morphology of Eustachian tubes. However, this approach was not too efficient, as samples were limited in number as they were difficult to obtain, and biological conditions were not reflected due to rigor mortis and atrophy during specimen preparation. We thus decided to use Multi-Slice CT (MSCT) to perform 3-dimensional (3-D) anatomic measurements of the Eustachian tube. MSCT has benefits of isotropy and high resolution, and it is useful in preparing images of any plane. Forty-eight adults were studied. For the purpose of measurement, various anatomic indices were carefully and precisely defined to identify each area on the image. Calculations based on each coordinate value enabled the measurement of length, diameter and angle of the Eustachian tube of normal adults. Therefore, measurements of the Eustachian tube, which were traditionally difficult as it is located in the deep part of the cranium, were simplified in many specimens. Mean value of total length was 39.2±3.2 mm, cartilage part length of the tube 30.0±2.7 mm and bony part 9.2±1.6 mm. Mean values of diameter of tympanic orifice were 5.2 x 3.2 mm, and pharyngeal orifice 9.7 x 4.4 mm. Mean value of angle between bony part and cartilage part was 160.9±13.6 degrees. This approach to anatomic measurement is expected to contribute greatly to investigation on various middle ear diseases. (author)

  18. Application of three-dimensional CT reconstruction cranioplasty

    International Nuclear Information System (INIS)

    Yan Shuli; Yun Yongxing; Wan Kunming; Qiu Jian

    2011-01-01

    Objective: To study the application of three-dimensional CT reconstruction in cranioplasty. Methods: 46 patients with skull defect were divided into two group. One group underwent CT examination and three-dimensional reconstruction, and then the Titanium nets production company manufactured corresponding titanium meshes were shaped those data before the operation. The other group received traditional operation in which titanium meshes were shaped during operation. The average time of operation were compared. Results: The average time of operation of the first group is 86.6±13.6 mins, and that of the second group is 115±15.0 mins. The difference of average operation time between the two groups was statistically significant. Conclusion: Three-dimensional CT reconstruction techniques contribute to shorten the average operation time, reduce the intensity of neurosurgeon's work and the patien's risk. (authors)

  19. Effect of Scanning and Reconstruction Parameters on Three Dimensional Volume and CT Value Measurement of Pulmonary Nodules: A Phantom Study

    Directory of Open Access Journals (Sweden)

    Datong SU

    2017-08-01

    Full Text Available Background and objective The computed tomography (CT follow-up of indeterminate pulmonary nodules aiming to evaluate the change of the volume and CT value is the common strategy in clinic. The CT dose needs to considered on serious CT scans in addition to the measurement accuracy. The purpose of this study is to quantify the precision of pulmonary nodule volumetric measurement and CT value measurement with various tube currents and reconstruction algorithms in a phantom study with dual-energy CT. Methods A chest phantom containing 9 artificial spherical solid nodules with known diameter (D=2.5 mm, 5 mm, 10 mm and density (-100 HU, 60 HU and 100 HU was scanned using a 64-row detector CT canner at 120 Kilovolt & various currents (10 mA, 20 mA, 50 mA, 80 mA,100 mA, 150 mA and 350 mA. Raw data were reconstructed with filtered back projection and three levels of adaptive statistical iterative reconstruction algorithm (FBP, ASIR; 30%, 50% and 80%. Automatic volumetric measurements were performed using commercially available software. The relative volume error (RVE and the absolute attenuation error (AAE between the software measures and the reference-standard were calculated. Analyses of the variance were performed to evaluate the effect of reconstruction methods, different scan parameters, nodule size and attenuation on the RPE. Results The software substantially overestimated the very small (D=2.5 mm nodule's volume [mean RVE: (100.8%±28%] and underestimated it attenuation [mean AAE: (-756±80 HU]. The mean RVEs of nodule with diameter as 5 mm and 10 mm were small [(-0.9%±1.1% vs (0.9%±1.4%], however, the mean AAEs [(-243±26 HU vs (-129±7 HU] were large. The ANOVA analysis for repeated measurements showed that different tube current and reconstruction algorithm had no significant effect on the volumetric measurements for nodules with diameter of 5 mm and 10 mm (F=5.60, P=0.10 vs F=11.13, P=0.08, but significant effects on the measurement of CT

  20. Evaluation of diagnostic quality in musculoskeletal three-dimensional CT scans

    International Nuclear Information System (INIS)

    Vannier, M.W.; Hildebolt, C.F.; Gilula, L.A.; Sutherland, C.J.; Offutt, C.J.; Drebin, R.; Mantle, M.; Giordono, T.A.

    1988-01-01

    A major application of three-dimensional computed tomography (CT) is in the imaging of the skeleton. Three-dimensional CT has an important role in determining the presence and extent of congenital and acquired orthopedic abnormalities. The objective of this study was to compare the diagnostic sensitivity and specificity of three-dimensional CT, planar CT, and plain radiography in the detection and characterization of orthopedic abnormalities. Three-dimensional CT scan reconstructions were obtained by two methods, surface reconstruction and volumetric techniques. Seventy patients were imaged with CT, three-dimensional CT, and plain radiography. The consensus opinion of experts with access to all images plus clinical history, surgical findings, and follow-up findings were taken as truth. Expert radiologists read these cases in a blinded fashion. The results were compared using receiver operating characteristic (ROC) analysis. The diagnostic value of each three-dimensional reconstruction method and the parameters used to perform the reconstructions were evaluated

  1. Three-dimensional CT of the pediatric spine

    International Nuclear Information System (INIS)

    Starshak, R.J.; Crawford, C.R.; Waisman, R.C.; Sty, J.R.

    1987-01-01

    CT of the spine has been shown to be useful in evaluating congenital, neoplastic, inflammatory, and traumatic lesions. Any portion of the neural arch may be involved by these disease processes. The complex nature of the spinal column can make evaluation of these abnormalities difficult on axial CT. This is especially true if the spine is distorted by scoliosis, kyphosis, or lordosis. This exhibit illustrates the advantages and drawbacks of three-dimensional CT reconstructed images of spinal abnormalities in children

  2. Phantom study on three-dimensional target volume delineation by PET/CT-based auto-contouring

    International Nuclear Information System (INIS)

    Zhang, Tiejiao; Sakaguchi, Yuichi; Mitsumoto, Katsuhiko; Mitsumoto, Tatsuya; Sasaki, Masayuki; Tachiya, Yosuke; Ohya, Nobuyoshi

    2010-01-01

    The aim of this study was to determine an appropriate threshold value for delineation of the target volume in positron emission tomography (PET)/CT and to investigate whether we could delineate a target volume by phantom studies. A phantom consisted of six spheres (φ10-37 mm) filled with 18 F solution. Data acquisition was performed PET/CT in non-motion and motion status with high 18 F solution and in non-motion status with low 18 F solution. In non-motion phantom experiments, we determined two types of threshold value, an absolute SUV (T SUV ) and a percentage of the maximum SUV (T % ). Delineation using threshold values was applied for all spheres and for selected large spheres (a diameter of 22 mm or larger). In motion phantom experiments, data acquisition was performed in a static mode (sPET) and a gated mode (gPET). CT scanning was performed with helical CT (HCT) and 4-dimentional CT (4DCT). The appropriate threshold values were aT % =27% and aT SUV =2.4 for all spheres, and sT % =30% and sT SUV =4.3 for selected spheres. For all spheres in sPET/HCT in motion, the delineated volumes were 84%-129% by the aT % and 34%-127% by the aT SUV . In gPET/4DCT in motion, the delineated volumes were 94-103% by the aT % and 51-131% by the aT SUV . For low radioactivity spheres, the delineated volumes were all underestimated. A threshold value of T % =27% was proposed for auto-contouring of lung tumors. Our results also suggested that the respiratory gated data acquisition should be performed in both PET and CT for target volume delineation. (author)

  3. Application of CT three-dimensional reconstruction in elbow injury

    International Nuclear Information System (INIS)

    Liang Wenhua; Qian Li

    2009-01-01

    Objective: To investigate the application of multi-slice spiral CT in fracture of elbow, and to study the value of different methods of the reconstruction. Methods: Thin line cross-section spiral CT scan was carried out in 13 cases with elbow injury, three-dimensional reconstruction was completed later. Several reconstructed image quality to display f the elbow fracture and dislocation were analyzed and compared. Results: 13 cases (17) elbow trauma included humeral media epicondyle fracture, humeral external epicondyle fracture, intercondylar fracture, olecranal fracture and radial head fracture. Among them, X-ray film showed negative in three sites, showed suspect fractures in 2 cases, and only showed single fracture in 2 cases. MPR reconstruction image could not only identify the diagnosis of fracture, but also provide further multi-angle display on fracture line and the extent of articular surface involvement. Surface reconstruction technology could exclude the impact of passive elbow flexion and display elbow injury more intuitively. Conclusion The elbow fracture dislocation could be showed clearly in multi-slice spiral CT, especially for complex fractures, with unmatched advantages compared to X-ray for clinical diagnosis and treatment determination. (authors)

  4. Integrated three-dimensional display of MR, CT, and PET images of the brain

    International Nuclear Information System (INIS)

    Levin, D.N.; Herrmann, A.; Chen, G.T.Y.

    1988-01-01

    MR, CT, and PET studies depict complementary aspects of brain anatomy and function. The authors' own image-processing software and a Pixar image computer were used to create three-dimensional models of brain soft tissues from MR images, of the skull and calcifications from CT scans, and of brain metabolism from PET images. An image correlation program, based on surface fitting, was used for retrospective registration and merging of these three-dimensional models. The results are demonstrated in a video clip showing how the operator may rotate and perform electronic surgery on the integrated, multimodality three-dimensional model of each patient's brain

  5. Two-and three-dimensional CT reconstruction

    International Nuclear Information System (INIS)

    Fishman, E.K.; Ney, D.R.; Magid, D.

    1990-01-01

    This paper determines the optimal imaging sequence for creating two- and three-dimensional (2D/3D) skeletal reconstructions from CT data. A cadaver femur, a bone phantom, and a surgically created fracture were scanned with varying protocols to determine the optimal protocol for creating 2D/3D images. The scanning protocols used varying section thickness (2, 4, and 8 mm) as well as scan spacing (2, 3, 4 and 8 mm). All images were reconstructed into 2D data sets with a bicubic interpolation and 3D datasets with volumetric rendering. The results were reviewed by two reviewers to determine the quality of images reconstruction

  6. A comparative study of linear measurement of the brain and three-dimensional measurement of brain volume using CT scans

    International Nuclear Information System (INIS)

    Hamano, K.; Iwasaki, N.; Takeya, T.; Takita, H.

    1993-01-01

    Parameters of linear measurement were compared with actual brain volume to assess the significance of linear measurements as indices of atrophy in 31 neurologically normal children and 22 neurologically abnormal children. Brain volume was established by means of an image-analyzing system using contiguous CT scans. The parameters or indices estimated were: (1) the maximum transverse width of both hemispheres, (2) the maximum longitudinal length of both hemispheres, (3) the maximum frontal subarachnoid space, (4) the maximum width of the interhemispheric fissure, (5) the maximum width of the Sylvian fissure, (6) Evans' ratio, (7) the maximum width of the third ventricle, (8) the cella media index, (9) the maximum width of the fourth ventricle. In neurologically normal children, the maximum transverse width of both hemispheres, the maximum longitudinal length of both hemispheres, the maximum width of the interhemispheric fissure and the maximum width of the Sylvian fissure correlated significantly with the combined volume (CV) of both hemipheres and basal ganglia. In particular, the maximum transverse width of both hemispheres and the maximum longitudinal length of both hemispheres had a high correlation. In neurologically abnormal children the maximum transverse width of both hemispheres and the maximum width of the interhemispheric fissure were significantly correlated with the CV of both hemispheres and basal ganglia. (orig.)

  7. Pulmonary sequestration: diagnosis with three dimensional reconstruction using spiral CT

    International Nuclear Information System (INIS)

    Nie Yongkang; Zhao Shaohong; Cai Zulong; Yang Li; Zhao Hong; Zhang Ailian; Huang Hui

    2003-01-01

    Objective: To evaluate the role of three dimensional (3D) reconstruction using spiral CT in the diagnosis of pulmonary sequestration. Methods: Ten patients with pulmonary sequestration were analyzed. The diagnoses were confirmed by angiography in 2 patients, by operation in 2 patients, and by CT angiography in 6 patients. All patients were examined with Philips SR 7000 or GE Lightspeed Plus scanner. CT images were transferred to a workstation and 3D reconstruction was performed. All images were reviewed and analyzed by two radiologists. Results: Among 10 patients, the pulmonary sequestration was in the right lower lobe in 1 patient and in the left lower lobe in 9 patients. Anomalous systemic arteries originated from thoracic aorta in 8 patients and from celiac artery in 2 patients. On plain CT scan, there were 4 patients with patchy opacities, 3 patients with hilar mass accompanying vascular engorgement and profusion in adjacent parenchyma, 2 patients with finger-like appendage surrounded by hyper-inflated lung, and 1 patient with lung mass-like lesion. Enhanced CT revealed anomalous systemic arteries in 9 patients and drainage vein in 7 patients. Maximum intensity projection (MIP) and curvilinear reconstruction could depict the abnormal systemic artery and drainage vein in sequestration. Surface shadow display (SSD) and volume rendering (VR) could delineate the anomalous systemic artery. Conclusion: 3D reconstruction with enhanced spiral CT can depict anomalous systemic artery and drainage vein and it is the first method of choice in diagnosing pulmonary sequestration

  8. Three-dimensional spiral CT of craniofacial malformations in children

    International Nuclear Information System (INIS)

    Binaghi, S.; Gudinchet, F.

    2000-01-01

    Objective. To assess the value of three-dimensional CT (3D CT) in the diagnosis and management of suspected paediatric craniofacial malformations. Materials and methods. Twenty-eight children (12 girls, 16 boys) with a mean age of 4 years, suffering from craniofacial or cervical malformations, underwent craniofacial spiral CT. 3D reformatting was performed using an independent workstation. Results. 3D CT allowed the preoperative evaluation of 16 patients with craniosynostosis and the post-surgical management of 2 patients. 3D CT clearly depicted malformations of the skull base involving the petrous bone in seven patients (four cases of Goldenhar-Gorlin syndrome, one case of Treacher-Collins syndrome and two cases of Crouzon's disease). Four patients with craniofacial clefts were also evaluated. Radiological findings were confirmed by the clinical and intraoperative findings in all patients that underwent surgical treatment. Movement artefacts and ''Lego effect'' related to abrupt change of cranial vault border were encountered and are discussed. Conclusions. 3D CT of the skull can safely and reliably identify paediatric craniofacial malformations involving bone, and it should be used as morphological mapping to help the surgeon in planning surgical treatment. (orig.)

  9. Three dimensional electrochemical system for neurobiological studies

    DEFF Research Database (Denmark)

    Vazquez, Patricia; Dimaki, Maria; Svendsen, Winnie Edith

    2009-01-01

    In this work we report a novel three dimensional electrode array for electrochemical measurements in neuronal studies. The main advantage of working with these out-of-plane structures is the enhanced sensitivity of the system in terms of measuring electrochemical changes in the environment...

  10. Three-dimensional visualization and characterization of bone structure using reconstructed in-vitro μCT images: A pilot study for bone microarchitecture analysis

    Energy Technology Data Exchange (ETDEWEB)

    Latief, Fourier Dzar Eljabbar, E-mail: fourier@fi.itb.ac.id [Physics of Earth and Complex Systems, Faculty of Mathematics and Natural Sciences, Institut Teknologi Bandung, Jl. Ganesha 10, Bandung 40132 (Indonesia); Dewi, Dyah Ekashanti Octorina [2Biomedical Engineering Research Division, School of Electrical Engineering and Informatics, Institut Teknologi Bandung, Jl. Ganesha 10, Bandung 40132 (Indonesia); Shari, Mohd Aliff Bin Mohd [Faculty of Electrical Engineering, Universiti Teknologi MARA Malaysia, 40000 Shah Alam, Selangor (Malaysia)

    2014-03-24

    Micro Computed Tomography (μCT) has been largely used to perform micrometer scale imaging of specimens, bone biopsies and small animals for the study of porous or cavity-containing objects. One of its favored applications is for assessing structural properties of bone. In this research, we perform a pilot study to visualize and characterize bone structure of a chicken bone thigh, as well as to delineate its cortical and trabecular bone regions. We utilize an In-Vitro μCT scanner Skyscan 1173 to acquire a three dimensional image data of a chicken bone thigh. The thigh was scanned using X-ray voltage of 45 kV and current of 150 μA. The reconstructed images have spatial resolution of 142.50 μm/pixel. Using image processing and analysis e.i segmentation by thresholding the gray values (which represent the pseudo density) and binarizing the images, we were able to visualize each part of the bone, i.e., the cortical and trabecular regions. Total volume of the bone is 4663.63 mm{sup 3}, and the surface area of the bone is 7913.42 mm{sup 2}. The volume of the cortical is approximately 1988.62 mm{sup 3} which is nearly 42.64% of the total bone volume. This pilot study has confirmed that the μCT is capable of quantifying 3D bone structural properties and defining its regions separately. For further development, these results can be improved for understanding the pathophysiology of bone abnormality, testing the efficacy of pharmaceutical intervention, or estimating bone biomechanical properties.

  11. Three-dimensional spiral CT for neurosurgical planning.

    Science.gov (United States)

    Klein, H M; Bertalanffy, H; Mayfrank, L; Thron, A; Günther, R W; Gilsbach, J M

    1994-08-01

    We carried out 22 examinations to determine the value of three-dimensional (3D) volumetric CT (spiral CT) for planning neurosurgical procedures. All examinations were carried out on a of the first generation spiral CT. A tube model was used to investigate the influence of different parameter settings. Bolus injection of nonionic contrast medium was used when vessels or strongly enhancing tumours were to be delineated. 3D reconstructions were carried out using the integrated 3D software of the scanner. We found a table feed of 3 mm/s with a slice thickness of 2 mm and an increment of 1 mm to be suitable for most purposes. For larger regions of interest a table feed of 5 mm was the maximum which could be used without blurring of the 3D images. Particular advantages of 3D reconstructed spiral scanning were seen in the planning of approaches to the lower clivus, acquired or congenital bony abnormalities and when the relationship between vessels, tumour and bone was important.

  12. Three-dimensional spiral CT for neurosurgical planning

    International Nuclear Information System (INIS)

    Klein, H.M.; Bertalanffy, H.; Mayfrank, L.; Thron, A.; Guenther, R.W.; Gilsbach, J.M.

    1994-01-01

    We carried out 22 examinations to determine the value of three-dimensional (3D) volumetric CT (spiral CT) for planning neurosurgical procedures. All examinations were carried out on a of the first generation spiral CT. A tube model was used to investigate the influence of different parameter settings. Bolus injection of nonionic contrast medium was used when vessels or strongly enhancing tumours were to be delineated. 3D reconstructions were carried out using the integrated 3D software of the scanner. We found a table feed of 3 mm/s with a slice thickness of 2 mm and an increment of 1 mm to be suitable for most purposes. For larger regions of interest a table feed of 5 mm was the maximum which could be used without blurring of the 3D images. Particular advantages of 3D reconstructed spiral scanning were seen in the planning of approaches to the lower clivus, acquired or congenital bony abnormalities and when the relationship between vessels, tumour and bone was important. (orig.)

  13. Trabecular bone strains around a dental implant and associated micromotions--a micro-CT-based three-dimensional finite element study.

    Science.gov (United States)

    Limbert, Georges; van Lierde, Carl; Muraru, O Luiza; Walboomers, X Frank; Frank, Milan; Hansson, Stig; Middleton, John; Jaecques, Siegfried

    2010-05-07

    The first objective of this computational study was to assess the strain magnitude and distribution within the three-dimensional (3D) trabecular bone structure around an osseointegrated dental implant loaded axially. The second objective was to investigate the relative micromotions between the implant and the surrounding bone. The work hypothesis adopted was that these virtual measurements would be a useful indicator of bone adaptation (resorption, homeostasis, formation). In order to reach these objectives, a microCT-based finite element model of an oral implant implanted into a Berkshire pig mandible was developed along with a robust software methodology. The finite element mesh of the 3D trabecular bone architecture was generated from the segmentation of microCT scans. The implant was meshed independently from its CAD file obtained from the manufacturer. The meshes of the implant and the bone sample were registered together in an integrated software environment. A series of non-linear contact finite element (FE) analyses considering an axial load applied to the top of the implant in combination with three sets of mechanical properties for the trabecular bone tissue was devised. Complex strain distribution patterns are reported and discussed. It was found that considering the Young's modulus of the trabecular bone tissue to be 5, 10 and 15GPa resulted in maximum peri-implant bone microstrains of about 3000, 2100 and 1400. These results indicate that, for the three sets of mechanical properties considered, the magnitude of maximum strain lies within an homeostatic range known to be sufficient to maintain/form bone. The corresponding micro-motions of the implant with respect to the bone microstructure were shown to be sufficiently low to prevent fibrous tissue formation and to favour long-term osseointegration. Copyright 2010 Elsevier Ltd. All rights reserved.

  14. [Three dimensional CT reconstruction system on a personal computer].

    Science.gov (United States)

    Watanabe, E; Ide, T; Teramoto, A; Mayanagi, Y

    1991-03-01

    A new computer system to produce three dimensional surface image from CT scan has been invented. Although many similar systems have been already developed and reported, they are too expensive to be set up in routine clinical services because most of these systems are based on high power mini-computer systems. According to the opinion that a practical 3D-CT system should be used in daily clinical activities using only a personal computer, we have transplanted the 3D program into a personal computer working in MS-DOS (16-bit, 12 MHz). We added to the program a routine which simulates surgical dissection on the surface image. The time required to produce the surface image ranges from 40 to 90 seconds. To facilitate the simulation, we connected a 3D system with the neuronavigator. The navigator gives the position of the surgical simulation when the surgeon places the navigator tip on the patient's head thus simulating the surgical excision before the real dissection.

  15. Trabecular bone strains around a dental implant and associated micromotions--a micro-CT-based three-dimensional finite element study.

    NARCIS (Netherlands)

    Limbert, G.; Lierde, C. van; Muraru, O.L.; Walboomers, X.F.; Frank, M.; Hansson, S.; Middleton, J.; Jaecques, S.

    2010-01-01

    The first objective of this computational study was to assess the strain magnitude and distribution within the three-dimensional (3D) trabecular bone structure around an osseointegrated dental implant loaded axially. The second objective was to investigate the relative micromotions between the

  16. Three-dimensional CT and MR imaging in congenital dislocation of the hip: Technical considerations

    International Nuclear Information System (INIS)

    Lang, P.; Steiger, P.; Lindquist, T.; Skinner, S.; Moore, S.; Chafetz, N.I.; Genant, H.K.

    1987-01-01

    Two-dimensional (2D) software techniques were developed to generate diagnostic-quality three-dimensional (3D) MR studies in two patients with congenital dislocation of the hip. Comparable 3D CT studies were obtained in two other patients. Unsharp masks were divided into the original MR images to correct for local variations in signal intensity. Combinations of first- and second-echo images improved the object contrast. Pixels with insufficient homogeneity relative to their neighboring data were excluded. CT did not require 2D preprocessing. Three-dimensional CT and MR images demonstrated subluxation and dislocation. 3D MR, in contrast to CT, demonstrated the cartilaginous femoral head. The described 2D MR preprocessing provides diagnostic-quality 3D MR studies. It will be useful for generating 3D MR images of other anatomic structures

  17. Three-dimensional monochromatic x-ray CT

    Science.gov (United States)

    Saito, Tsuneo; Kudo, Hiroyuki; Takeda, Tohoru; Itai, Yuji; Tokumori, Kenji; Toyofuku, Fukai; Hyodo, Kazuyuki; Ando, Masami; Nishimura, Ktsuyuki; Uyama, Chikao

    1995-08-01

    In this paper, we describe a 3D computed tomography (3D CT) using monochromatic x-rays generated by synchrotron radiation, which performs a direct reconstruction of 3D volume image of an object from its cone-beam projections. For the develpment of 3D CT, scanning orbit of x-ray source to obtain complete 3D information about an object and corresponding 3D image reconstruction algorithm are considered. Computer simulation studies demonstrate the validities of proposed scanning method and reconstruction algorithm. A prototype experimental system of 3D CT was constructed. Basic phantom examinations and specific material CT image by energy subtraction obtained in this experimental system are shown.

  18. Three-dimensional multislice CT imaging of otitis media

    International Nuclear Information System (INIS)

    Suzuki, Miyako; Yoshikawa, Hiroshi; Hosokawa, Akira; Furukawa, Tomoyasu; Ichikawa, Ginichiro; Wada, Akihiro; Ando, Ichiro

    2002-01-01

    In recent years, the multislice CT system has come into practical use that enables table movement of half mm, resulting in a significant improvement in resolution. The use of this CT system enables to depict the entire auditory ossicles, including the stapes. 3D reconstruction was performed using helical CT data in 5 patients with chronic otitis media and 5 patients with cholesteatoma. An Aquilion Multi (Toshiba) multislice helical CT scanner and a Xtension (Toshiba) image workstation were used in this study. We demonstrated the 3D display with axial, coronal and sagittal images. Compared with the normal ears, it was necessary to set a higher threshold for the affected ears. It is important to select suitable threshold for demonstration of 3D images optimally. Bone destruction of the stapes was confirmed at surgery in 2 ears. The stapes was observed at 3D-CT imaging in other 18 ears. It was found that the 3D images of the ossicular destruction in ears with cholesteatoma were consistent with surgical findings. It is therefore concluded that 3D imaging of the middle ear using a multislice CT scanner is clinically useful. (author)

  19. Three-dimensional multislice CT imaging of otitis media

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Miyako [Yanagibasi Hospital, Tokyo (Japan); Yoshikawa, Hiroshi; Hosokawa, Akira; Furukawa, Tomoyasu; Ichikawa, Ginichiro [Juntendo Univ., Tokyo (Japan). School of Medicine; Wada, Akihiro; Ando, Ichiro [Juntendo Univ., Chiba (Japan). Urayasu Hospital

    2002-07-01

    In recent years, the multislice CT system has come into practical use that enables table movement of half mm, resulting in a significant improvement in resolution. The use of this CT system enables to depict the entire auditory ossicles, including the stapes. 3D reconstruction was performed using helical CT data in 5 patients with chronic otitis media and 5 patients with cholesteatoma. An Aquilion Multi (Toshiba) multislice helical CT scanner and a Xtension (Toshiba) image workstation were used in this study. We demonstrated the 3D display with axial, coronal and sagittal images. Compared with the normal ears, it was necessary to set a higher threshold for the affected ears. It is important to select suitable threshold for demonstration of 3D images optimally. Bone destruction of the stapes was confirmed at surgery in 2 ears. The stapes was observed at 3D-CT imaging in other 18 ears. It was found that the 3D images of the ossicular destruction in ears with cholesteatoma were consistent with surgical findings. It is therefore concluded that 3D imaging of the middle ear using a multislice CT scanner is clinically useful. (author)

  20. Study on three dimensional seismic isolation system

    International Nuclear Information System (INIS)

    Morishita, Masaki; Kitamura, Seiji

    2003-01-01

    Japan Nuclear Cycle Development Institute (JNC) and Japan Atomic Power Company (JAPC) launched joint research programs on structural design and three-dimensional seismic isolation technologies, as part of the supporting R and D activities for the feasibility studies on commercialized fast breeder reactor cycle systems. A research project by JAPC under the auspices of the Ministry of Economy, Trade, and Industry (METI) with technical support by JNC is included in this joint study. This report contains the results of the research on the three-dimensional seismic isolation technologies, and the results of this year's study are summarized in the following five aspects. (1) Study on Earthquake Condition for Developing 3-dimensional Base Isolation System. The case study S2 is one of the maximum ground motions, of which the records were investigated up to this time. But a few observed near the fault exceed the case study S2 in the long period domain, depending on the fault length and conditions. Generally it is appropriate that the response spectra ratio (vertical/horizontal) is 0.6. (2) Performance Requirement for 3-dimensional Base Isolation System and Devices. Although the integrity map of main equipment/piping dominate the design criteria for the 3-dimensional base isolation system, the combined integrity map is the same as those of FY 2000, which are under fv=1Hz and over hv=20%. (3) Developing Targets and Schedule for 3-dimensional Isolation Technology. The target items for 3-dimensional base isolation system were rearranged into a table, and developing items to be examined concerning the device were also adjusted. A development plan until FY 2009 was made from the viewpoint of realization and establishment of a design guideline on 3-dimensional base isolation system. (4) Study on 3-dimensional Entire Building Base Isolation System. Three ideas among six ideas that had been proposed in FY2001, i.e., '3-dimensional base isolation system incorporating hydraulic

  1. Three-dimensional-CT imaging of colorectal disease with thin collimation helical CT scanning

    International Nuclear Information System (INIS)

    Ogura, Toshihiro; Koizumi, Koichi; Sakai, Tatsuya; Kai, Shunkichi; Takatsu, Kazuaki; Maruyama, Masakazu

    1998-01-01

    We have conducted research on three-dimensional (3D)-CT-colonoscopy with thin collimation helical CT scanning over the past three years. This has lately become a subject of special interest. 3D-CT-colonoscopy has three kinds of visualizing methods depending on the threshold setting of CT values. The first one is the virtual endoscopy method which is displayed in a similar fashion to colonoscopic images. The second one is the air image method using the air in the digestive tract as a contrast medium. The third one is the pseudo-tract method which has characteristics of both virtual endoscopy and the air image method and visualizes in a shape of the digestive tract. The image visualized by 3D-CT-colonoscopy is similar to that of conventional colonoscopy and barium enema study, which is obtained with minimal invasion to patients. Obvious advanced carcinomas were easily visualized, and even a small flat polyp measuring 5 mm in size, was able to be observed retrospectively. The characteristics of our method are that we can easily make an examination in a short time and with little dependence on expert technique. Also patients have little discomfort compared to that experienced during colonoscopy and barium enema study. Important features are as follows; long calculation time, insufficient air insufflation, fecal material in the patient''s bowel, whole abdominal scan, and spatial resolution. In the near future, a multislice CT scanner system will have ability to overcome these problems. Therefore, 3D-CT-colonoscopy might be applied in the future for first line examination as a mass screening for colorectal carcinoma. (author)

  2. Three-dimensional CT imaging of soft-tissue anatomy

    International Nuclear Information System (INIS)

    Fishman, E.K.; Ney, D.R.; Magid, D.; Kuhlman, J.E.

    1988-01-01

    Three-dimensional display of computed tomographic data has been limited to skeletal structures. This was in part related to the reconstruction algorithm used, which relied on a binary classification scheme. A new algorithm, volumetric rendering with percentage classification, provides the ability to display three-dimensional images of muscle and soft tissue. A review was conducted of images in 35 cases in which muscle and/or soft tissue were part of the clinical problem. In all cases, individual muscle groups could be clearly identified and discriminated. Branching vessels in the range of 2.3 mm could be identified. Similarly, lymph nodes could be clearly defined. High-resolution three-dimensional images were found to be useful both in providing an increased understanding of complex muscle and soft tissue anatomy and in surgical planning

  3. Three-dimensional display of the heart, aorta, lungs, and airway using CT

    International Nuclear Information System (INIS)

    Fram, E.K.; Godwin, J.D.; Putman, C.E.

    1982-01-01

    In previous studies of human anatomy, three-dimensional display of CT data has required laborious manual boundary tracking, except for high-contrast structures such as the spine. Automated boundary tracking techniques have been extended so that they can function well for both high-contrast and soft-tissue interfaces. These methods have been applied to the in vivo study of human lungs, heart, aorta, and larynx in this paper

  4. Diagnosis of temporal bone diseases using three-dimensional images with multislice CT

    Energy Technology Data Exchange (ETDEWEB)

    Toyama, Yoshihiro; Togami, Taro; Murota, Makiko; Fukunaga, Kotaro; Hino, Ichiro; Sato, Katashi; Ohkawa, Motoomi [Kagawa Medical Univ., Miki (Japan)

    2001-08-01

    We evaluated the usefulness of three-dimensional images with multislice CT in the temporal bone diseases. Fifty-nine cases (26 with medial otitis, 8 choresteatoma, 10 congenital malformation, 3 high jugular bulb, 2 otosclerosis, and 10 others) were included in this study. In the ossicular and inner ear lesions, oblique multiplanar images of the long axis of each ossicle was useful the detection of abnormality. Structural deformity of ossicles and bony labyrinth were clearly delineated by surface rendering images. (author)

  5. Technique and value of three dimensional reconstruction of stones in the renal pelvis using spiral CT

    International Nuclear Information System (INIS)

    Fink, B.K.; Fink, U.; Pentenrieder, M.; Kohz, P.; Englmeier, H.K.; Schmeller, N.

    1994-01-01

    5 patients with staghorn calculi in the renal pelvis were examined by spiral CT. From the raw data three dimensional reconstructions of the stones were obtained. In all patients it was possible to compare the three dimensional model with the stone following performance of percutaneous lithopaxy and endoscopic removal of the fragments. In all cases the three dimensional reconstruction provided a realistic image of the stones and was of practical value for the urologist for preoperative diagnosis and intraoperative control. (orig.) [de

  6. Adult Sex Identification Using Three-Dimensional Computed Tomography (3D-CT of the Pelvis: A Study Among a Sample of the Egyptian Population

    Directory of Open Access Journals (Sweden)

    Enas M. A. Mostafa

    2016-06-01

    Full Text Available Sex identification of unknown human skeletal remains is of great importance in establishing identity and individuality. In adults, the hip bone is the most reliable sex indicator because of its sexual dimorphism. Each population should have its own specific standards of identification. The objective of this study is to develop a logistic regression formula for adult sex identification using threedimensional computed tomography (3D-CT of the pelvis and to perform an assessment of its validity in sex determination among a sample of the Egyptian population in the Suez Canal region. 141 pelvic-abdominal CT images (free of any pelvic orthopaedic disorder were included; they were reconstructed to produce 3D-CT pelvic images which were divided into a calibration group (47 male and 47 female and a test group (47 CT images the sex of which was unknown to the observers. Twenty radiometric variables were measured for the calibration group. A logit response formula for sex prediction was developed and applied on the test group for sex prediction. The logit response formula for the test sample showed sensitivity, specificity, and an overall accuracy of 100%. The proposed method represents a quick and reliable metric method in establishing sex from a CT image of the pelvis bone.

  7. Three dimensional positron-CT: 3D-PET

    International Nuclear Information System (INIS)

    Ishii, K.

    2000-01-01

    Positron-CT, namely the positron emission tomograph (PET) provides us the metabolism images obtained by the administration of the drug labeled by the positron emission nuclide in the human body. For example, the carbohydrate metabolism image is obtained by the administration of glucose labelled by 18 F-radioisotopes, and it can be applied to early detection of the cancer and research of high-order function of the brain. As well as X-ray CT, the examine receives the exposure in the positron CT. 3D-PET is based on the solid measurement of γ-rays, therefore, the detection sensitivity of 3D-PET becomes very high and it is possible to drastically reduce the dose of the positron emission nuclide. Because the exposure is reduced to the utmost, the positron CT diagnosis would be possible for the child and the exposure of positron CT doctor in charge can be also reduced. This ideal functional diagnostic imaging equipment, namely, 3D-PET is introduced here. (author)

  8. Usefulness of preoperative three dimensional CT in laparoscopic cholecystectomy. Especially, its comparison to ERC

    International Nuclear Information System (INIS)

    Machida, Hiromichi; Nakaya, Yuzou; Kojima, Kojirou

    1996-01-01

    We studied the usefulness of three dimensional helical CT (3D-CT) combined with drip infusion cholangiography for determining the application of laparoscopic cholecystectomy (LC) and evaluating the cholecyst severity. The subjects were 56 patients who underwent LC with preoperative 3D-CT. Particularly, in 42 patients undergoing endoscopic retrograde cholangiography (ERC) and 3D-CT simultaneously, the results with both methods were compared. The detection rates of the original site, forward and backward direction, and left and right direction in the confluence form of the cystic duct by means of 3D-CT versus ERC were 100% vs. 92.9% 92.9% vs. 71.4%, and 92.9% vs. 88.1%, respectively. Abnormal biliary distribution was visualized in 5 cases and all of them were depicted by 3D-CT. The 3D-CT was superior to ERC in terms of X-ray dose and cost. These results indicate the usefulness of 3D-CT as a LC preoperative examination. (author)

  9. Utility of three-dimensional helical CT in the diagnosis of breast cancer

    International Nuclear Information System (INIS)

    Maeda, Yoshiaki; Hata, Yoshinobu; Matsuoka, Shinnichi; Nakajima, Nobuhisa; Ito, Toichi; Osada, Tadahiro; Sano, Fumio

    2004-01-01

    Although utility of three-dimensional (3D) helical CT for preoperative examination of breast cancer has been discussed, the accuracy of the helical CT in diagnosing breast cancer has not been fully evaluated. In this study 56 malignant and 28 benign breast tumors were evaluated preoperatively with 3D-helical CT, and their imaging results were compared with pathological findings of surgical specimens. Helical CT identified the presence of malignancy in 54 out of the 56 cancer cases tested and the sensitivity and specificity in distinguishing between malignant and benign tumors were 82% and 57%, respectively. The sensitivity and specificity in diagnosing the presence of metastatic axillary lymph nodes using helical CT were 70% and 80%, respectively. The sensitivity and specificity in diagnosing the presence of extensive intraductal component (EIC) using helical CT were 71% and 86%, respectively. Helical CT visualized all of the tumors in multifocal breast cancer cases. In conclusion, 3D-helical CT is a useful modality for preoperative examination of breast cancer, especially for assessing axillary lymph node status, and EIC, and will be helpful for conducting sentinel lymph node biopsy (SNLB) and breast-conserving surgery. (author)

  10. Postoperative assessment of surgical results using three dimensional surface reconstruction CT (3D-CT) in a craniofacial anomaly

    International Nuclear Information System (INIS)

    Nishimura, Jiro; Sato, Kaoru; Nishimoto, Hiroshi; Tsukiyama, Takashi; Fujioka, Mutsuhisa; Akagawa, Tetsuya.

    1988-01-01

    In 1983, Michael W. Vannier and Jeffrey L. Marsh developed a computer method that reconstructs three dimensional (3D) born and soft tissue surfaces, given a high resolution CT scan-series of the facial skeleton. This method has been applied to craniofacial anomalies, basal encephaloceles, and musculoskeletal anomalies. In this study, a postoperative assessment of the craniofacial surgical results has been accomplished using this 3D-CT in 2 children with craniofacial dysmorphism. The authors discuss the advantages of this 3D-CT imaging method in the postoperative assessments of craniofacial anomalies. Results are detailed in the following listing : 1) a postoperative 3D-CT reveals the anatomical details corrected by the craniofacial surgery more precisely and stereographically than conventional radiological methods ; 2) secondary changes of the cranium after the surgery, such as bony formation in the area of the osteotomy and postoperative asymmetric deformities, are detected early by the 3D-CT imaging technique, and, 3) 3D-CT mid-sagittal and top axial views of the intracranial skull base are most useful in postoperative assessments of the surgical results. Basesd on our experience, we expect that three dimensional surface reconstructions from CT scans will become to be used widely in the postoperative assessments of the surgical results of craniofacial anomalies. (author)

  11. Application status of three-dimensional CT reconstruction in hepatobiliary surgery

    Directory of Open Access Journals (Sweden)

    JIANG Chao

    2017-02-01

    Full Text Available With the development of imaging technology, three-dimensional CT reconstruction has been widely used in hepatobiliary surgery. Three-dimensional CT reconstruction can divide and reconstruct two-dimensional images into three-dimensional images and clearly show the location of lesion and its relationship with the intrahepatic bile duct system. It has an important value in the preoperative assessment of liver volume, diagnosis and treatment decision-making process, intraoperative precise operation, and postoperative individualized management, and promotes the constant development of hepatobiliary surgery and minimally invasive technology, and therefore, it holds promise for clinical application.

  12. Three-dimensional versus conventional CT in the evaluation of facial trauma

    International Nuclear Information System (INIS)

    Mayer, J.S.; Yeakley, J.W.; Kulkarni, M.V.; Wainwright, D.J.; Lee, K.F.; Harris, J.H. Jr.

    1987-01-01

    An accurate knowledge of the three-dimensional pattern of facial fractures is surgically important. This exhibit shows how this may be difficult if not impossible to obtain using axial and reconstructed CT images and how 3D CT is superior in this regard. 3D CT displays the course of anterior and lateral facial fractures and the spatial orientation of bone fragments that can be missed when using other CT techniques. 3D CT and facial CT images can be generated from a single CT examination and are complementary. Together they display posttraumatic facial anatomy better than conventional planar CT images

  13. Three dimensional CT of stapes. Stapedial imagings in dry temporal bone and clinical applications

    Energy Technology Data Exchange (ETDEWEB)

    Edamatsu, Hideo; Kubota, Osamu; Yamashita, Koichi [Kanazawa Medical Univ., Ishikawa (Japan)

    1995-03-01

    This study was performed to evaluate the usefulness and limitations of three dimensional (3-D) imagings of stapes in the middle ear by high speed helical CT. One dissected human temporal bone, ten normal and diseased ears were scanned with a slice of 1.0 mm and reconstructed in a thickness of 0.2-0.5 mm. Every specimen of 3-D can be observed in any plane and from any direction. Ossicular imagings of the temporal bone in 3-D were reconstructed as if the malleus, incus and stapes were observed under microscope. The whole structure of stapes was impossible to be represented by two dimensional CT heretofore in use, but 3-D in our study showed the head, crus and foot plate of the stapes in detail. Stapedial imagings of 3-D CT in normal ears showed the same findings as those recorded in temporal bone. Preoperative diagnostic findings of ossicles in the affected ears were very useful. Especially in ossicular anomalies, 3-D CT was positive in diagnosis and its accuracies were confirmed with operative observation. For the postoperative evaluation concerning the ossicular reconstruction, i.e. TORP and PORP, 3-D CT was also important method. It could present an anatomical relation between those prosthesis and the oval window. High speed helical CT can scan an object more quickly and clearly than formerly used CT, and its biological damage for human is less than that of the others. 3-D CT can be more clearly reconstructed with helical CT than former CT. (author).

  14. Three-dimensional visualization of CT data in medical radiology

    International Nuclear Information System (INIS)

    Rieker, O.

    2000-01-01

    3D visualisation of the liver is much too complex a task for conventional methods. Superposed structures must be suppressed, while tumours and the artery must be enhanced. A combination of volume rendering and segmentation is recommended. Virtual planning of liver resections requires a mathematical model, e.g. analysis of the vessel tree with spherical shells. The use of Windows-NT may be an advantage of the Mainz project as it permits the use of a common PC. It is expected that 3D CT imaging will bring about dramatic changes in surgery of the liver. 3D reconstructions of the liver will result in individualized, parenchyma-saving resection proposals which deviate from the idealized resection according to Couinaud. (orig.) [de

  15. Clinical assessment of hypopharyngeal and laryngeal disorders by three-dimensional multidetector-row CT. Feasibility of imaging during phonation

    International Nuclear Information System (INIS)

    Tan, Xiaotian

    2002-01-01

    The hypopharynx and larynx can adapt their structures to physiological functions. To clarify the relation between morphologic changes and the development of pharyngeal and laryngeal disorders, images of the hypopharynx and larynx were obtained by multidetector-row CT (MD-CT) during phonation and quiet breathing. The clinical usefulness of such imaging study was assessed by comparing the images taken in the two phases. The study included 23 subjects, 20 patients with a hypopharyngeal or laryngeal disorder and 3 healthy volunteers. MD-CT scanning of the hypopharynx and larynx was not influenced by breathing and body movement. The volume rendering (VR) method was useful in that three-dimensional imaging could visualize the internal structure of the hypopharynx and larynx. Thus, the volume rendering method can be regarded as a virtual three-dimensional method. The normal anatomic structure of the hypopharynx and larynx were depicted in full and three-dimensionally. The extent of hypopharyngeal and laryngeal cancer was shown clearly. Edema due to paralysis of recurrent nerve was demonstrated in full and three-dimensionally, providing for functional diagnosis. In the case of mucosal edema caused by trauma, the extent of the edema and its effect on the airway were clearly observed. These results suggest that MD-CT with three-dimensional imaging during phonation is useful in the diagnosis of hypopharyngeal and laryngeal disorders. (author)

  16. Synthetic display of three-dimensional CT and MPR for gastric neoplasm

    International Nuclear Information System (INIS)

    Ogura, Toshihiro; Maruyama, Masakazu

    1998-01-01

    We attempted to obtain synthesized three dimensional (3D) and MPR (Multi Planar Reconstruction) helical CT scans (3D-MPR-CT) of gastric neoplasm by using the air as a contrast medium, and we assessed the usefulness of 3D-MPR-CT gastroendoscopy in the diagnosis of gastric neoplasm. Five minutes before the scan, 20 mg Scopolamine Butylbromide (Buscopan) was injected intramuscularly to minimize gastric peristalsis. An effervescent agent (bubble-make granules) was fed to extend the stomach wall. Non-ionic contrast material (100 mL) was power injected immediately before the scan start. Axial images were obtained with an intersection gap of 5-mm, a 5-mm/sec table speed, and 1-mm reconstruction intervals. 3D-MPR-CT images were reconstructed from these images. In abdominal study, 3D-MPR-CT images enabled the visualization of neoplasm and its adjacent structures in versatile directions, including a view similar to endoscopic observation, proximal aspect of narrowing by tumor and also could get the information about invasive depth of gastric neoplasm. Reports on some clinical cases and the advantages and disadvantages of 3D-MPR-CT gastroendoscopy were discussed. (author)

  17. Three-dimensional helical CT for treatment planning of breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Hiramatsu, Hideko; Enomoto, Kohji; Ikeda, Tadashi [Keio Univ., Tokyo (Japan). School of Medicine] [and others

    1999-01-01

    The role of three-dimensional (3D) helical CT in the treatment planning of breast cancer was evaluated. Of 36 patients examined, 30 had invasive ductal carcinoma, three had invasive lobular carcinoma, one had DCIS, one had DCIS with minimal invasion, and 1 had Paget`s disease. Patients were examined in the supine position. The whole breast was scanned under about 25 seconds of breath-holding using helical CT (Proceed, Yokogawa Medical Systems, or High-speed Advantage, GE Medical Systems). 3D imaging was obtained with computer assistance (Advantage Windows, GE Medical Systems). Linear and/or spotty enhancement on helical CT was considered to suggest DCIS or intraductal spread in the area surrounding the invasive cancer. Of 36 patients, 24 showed linear and/or spotty enhancement on helical CT, and 22 of those 24 patients had DCIS or intraductal spread. In contrast, 12 of 36 patients were considered to have little or no intraductal spread on helical CT, and eight of the 12 patients had little or no intraductal spread on pathological examination. The sensitivity, specificity, and accuracy rates for detecting intraductal spread on MRI were 85%, 80%, and 83%, respectively. 3D helical CT was considered useful in detecting intraductal spread and planning surgery, however, a larger study using a precise correlation with pathology is necessary. (author)

  18. Three-dimensional CT endoscopic images of the larynx. Clinical application of helical CT

    International Nuclear Information System (INIS)

    Yumoto, Eiji; Sanuki, Tetsuji; Yasuhara, Yoshifumi; Ochi, Takashi

    1998-01-01

    Twenty-seven patients with several laryngeal ailments underwent helical computed tomography (CT) on 37 occasions. Ten of these 27 patients suffered from unilateral vocal fold paralysis (UVFP). Three-dimensional (3D) images of the laryngeal lumen viewed from various angles were produced for all sets of CT volumetric data, except for three which contained excessive motion artifacts. The present paper examined whether 3D endoscopic images could offer useful diagnostic and therapeutic information about UVFP. The 3D endoscopic images viewed from the tracheal side and the hemilaryngeal images viewed from the opposite side could delineate the vocal folds, ventricular fold and ventricle three-dimensionally. Atrophy and hypotonic changes to the vocal fold and expansion of the ventricle on the affected side were clearly shown. The 3D endoscopic images accurately showed the phonosurgical effects on the laryngeal structures. The 3D endoscopic images could be produced even when the vocal folds could not be observed with conventional endoscopy due to their overadduction. Multiplanar reconstruction (MPR) images in the coronal plane were reconstructed at a right angle to the glottic axis when the whole larynx was deviated. In addition, coronal MPR images showed a better resolution among the different layers of the vocal fold soft tissue than X-ray tomography. In conclusion, 3D endoscopic images combined with coronal MPR images can provide useful diagnostic an therapeutic information about UVFP, although motion artifacts may occur. (author)

  19. Three dimensional analysis of coelacanth body structure by computer graphics and X-ray CT images

    International Nuclear Information System (INIS)

    Suzuki, Naoki; Hamada, Takashi.

    1990-01-01

    Three dimensional imaging processes were applied for the structural and functional analyses of the modern coelacanth (Latimeria chalumnae). Visualization of the obtained images is performed with computer graphics on the basis of serial images by an X-ray CT scanning method. Reconstruction of three dimensional images of the body structure of coelacanth using the volume rendering and surface rendering methods provides us various information about external and internal shapes of this exquisite fish. (author)

  20. Evaluation of the relationship between extremity soft tissue sarcomas and adjacent major vessels using contrast-enhanced multidetector CT and three-dimensional volume-rendered CT angiography - A preliminary study

    International Nuclear Information System (INIS)

    Li, YangKang; Lin, JianBang; Cai, AiQun; Zhou, XiuGuo; Zheng, Yu; Wei, XiaoLong; Cheng, Ying; Liu, GuoRui

    2013-01-01

    Background: Accurate description of the relationship between extremity soft tissue sarcoma and the adjacent major vessels is crucial for successful surgery. In addition to magnetic resonance imaging (MRI) or in patients who cannot undergo MRI, two-dimensional (2D) postcontrast computed tomography (CT) images and three-dimensional (3D) volume-rendered CT angiography may be valuable alternative imaging techniques for preoperative evaluation of extremity sarcomas. Purpose: To preoperatively assess extremity sarcomas using multidetector CT (MDCT), with emphasis on postcontrast MDCT images and 3D volume-rendered MDCT angiography in evaluating the relationship between tumors and adjacent major vessels. Material and Methods: MDCT examinations were performed on 13 patients with non-metastatic extremity sarcomas. Conventional CT images and 3D volume-rendered CT angiography were evaluated, with focus on the relationship between tumors and adjacent major vessels. Kappa consistency statistics were performed with surgery serving as the reference standard. Results: The relationship between sarcomas and adjacent vessels was described as one of three patterns: proximity, adhesion, and encasement. Proximity was seen in five cases on postcontrast CT images or in eight cases on volume-rendered images. Adhesion was seen in three cases on both postcontrast CT images and volume-rendered images. Encasement was seen in five cases on postcontrast CT images or in two cases on volume-rendered images. Compared to surgical results, postcontrast CT images had 100% sensitivity, 83.3% specificity, 87.5% positive predictive value, 100% negative predictive value, and 92.3% accuracy in the detection of vascular invasion (κ = 0.843, P = 0.002). 3D volume-rendered CT angiography had 71.4% sensitivity, 100% specificity, 100% positive predictive value, 75% negative predictive value, and 84.6% accuracy in the detection of vascular invasion (κ = 0.698, P = 0.008). On volume-rendered images, all cases

  1. Clinical application of three-dimensional spiral CT cerebral angiography with volume rendering

    International Nuclear Information System (INIS)

    Duan Shaoyin; Huang Xi'en; Kang Jianghe; Zhang Dantong; Lin Qingchi; Cai Guoxiang; Xu Meixin; Pang Ruilin

    2002-01-01

    Objective: To study the methodology and assess the clinical value of three-dimensional CT angiography (3D-CTA) with volume rendering (VR) in cerebral vessels. Methods: Sixty-two patients were examined by means of 3D-CTA with volume rendering. VR was used in the reconstruction of 3D images, and the demonstration of normal vessels and vascular lesions were particularly analyzed. At the same time, comparisons were made between the images of VR and SSD, MIP, and also between the diagnosis of VR-CTA and DSA or postoperative results. Results: In VR images, cerebral vessel routes and vessel cavities were showed clearly, while the relationship among vascular lesions, surrounding vessels, and neighboring structure was distinguished. 50 cases (80.6%) were found positive, 48 of which were correct and 2 were false-positive compared with DSA or postoperative results. The accurate rate of diagnosis was 96.0%. There was no obvious difference in showing the cerebral vessel among the images of VR, SSD and MIP (P > 0.25). Conclusion: Three-dimensional CT cerebral angiography with VR is a new noninvasive effective method. It can even partly replace the DSA. The 3D-images have the characteristics of showing the cerebral vascular cavity and overlapped vessels without cutting the skull

  2. Computational study of three-dimensional wake structure

    International Nuclear Information System (INIS)

    Himeno, R.; Shirayama, S.; Kamo, K.; Kuwahara, K.

    1986-01-01

    Three-dimensional wake structure is studied by numerically solving the incompressible Navier-Stokes equations. Results are visualized by a three-dimensional color graphic system. It was found that a pair of vortex tubes separated from a body plays the most important role in the wake. Near the body vortex tubes are rather stable, however, they gradually become unsteady as they flow down

  3. A comparative study of three-dimensional reconstructive images of temporomandibular joint using computed tomogram

    International Nuclear Information System (INIS)

    Lim, Suk Young; Koh, Kwang Joon

    1993-01-01

    The purpose of this study was to clarify the spatial relationship of temporomandibular joint and to an aid in the diagnosis of temporomandibular disorder. For this study, three-dimensional images of normal temporomandibular joint were reconstructed by computer image analysis system and three-dimensional reconstructive program integrated in computed tomography. The obtained results were as follows : 1. Two-dimensional computed tomograms had the better resolution than three dimensional computed tomograms in the evaluation of bone structure and the disk of TMJ. 2. Direct sagittal computed tomograms and coronal computed tomograms had the better resolution in the evaluation of the disk of TMJ. 3. The positional relationship of the disk could be visualized, but the configuration of the disk could not be clearly visualized on three-dimensional reconstructive CT images. 4. Three-dimensional reconstructive CT images had the smoother margin than three-dimensional images reconstructed by computer image analysis system, but the images of the latter had the better perspective. 5. Three-dimensional reconstructive images had the better spatial relationship of the TMJ articulation, and the joint space were more clearly visualized on dissection images.

  4. Three dimensional plastic model of the skull from CT images by using photocurable polymer

    International Nuclear Information System (INIS)

    Goto, Masaaki; Katsuki, Takeshi; Uchida, Yuuki; Ihara, Kouichiro; Noguchi, Nobuhiro

    1992-01-01

    Three dimensional analysis in medicine is increasingly becoming a valuable tool in preoperative planning, educating to students, and explaining to patients. Recently three dimensional reconstruction technology has been coupled with computerized resin hardening processes to create acrylic models from the three dimensional reconstruction data. We have fabricated two anatomical models of the skull by the computer controlled resin hardening device. Three dimensional data were created by the three-dimensional reformation system (TRI). As data entry and storage process, contour of bone tissue is manually drawn from each serial CT photographic image of transverse skull sections. These traces are then input to the frame memory by way of the video camera. The computer stores the X, Y coordinates of points along an outline as it is traced. A depth value into the structure, assigned to each section, provides the Z coordinate, that is, the third dimension. Wire frame image is generated by using the storage data. The final image produced by hidden surface removal and shading is displayed on a full color graphic display monitor. Anatomical resin models were generated by a photo hardening device which is controlled by a minicomputer and three dimensional reconstruction data. He-Cd laser beam (wave length: 325 nm) conducted through the fibers scans the bottom of the monometer liquid surface according to the each CT contour data. The elevator moves up after the polymerization of the liquid has been performed in one slice. This device is suitable for the creation of human anatomical structure because the branched form and hollow model can be made easily. Three dimensional resin models are more useful for simulation surgery, education, and explanation than computer aided three-dimensional images. (author)

  5. Efficacy of dynamic CT perfusion imaging in conjunction with three dimensional CT angiography for the evaluation of acute ischemic stroke

    Energy Technology Data Exchange (ETDEWEB)

    Nakaguchi, Hiroshi; Teraoka, Akira; Adachi, Shinobu; Yanagibashi, Kazutaka [Teraoka Memorial Hospital, Shinichi, Hiroshima (Japan)

    2003-01-01

    Through the use of a high-speed spiral CT scanner (GEMedical HiSpeedZX/i), CT/P/A technique, where conventional CT, CT perfusion imaging (CTP) and CT angiography (CTA) are consecutively performed, can now be performed with an imaging time of 90 seconds and a total contrast medium volume of 100 ml. A prospective clinical study was performed to ascertain the effectiveness of CT/P/A in diagnosing acute ischemic strokes. Twenty-nine consecutive patients of Teraoka Memorial Hospital suspected of suffering from the occlusion or constriction of cerebral arteries and who underwent CT/P/A within 3 hours from the onset served as subjects. The sensitivity, specificity, or Odds ratio of CTP and CTA in detecting lesions that caused cerebral infarction was calculated. CTP detected a hypoperfusion area with a sensitivity, specificity, and Odds ratio of 80%, 64%, and 7.2. The sensitivity in lobar infarcts, white matter infarcts, basal ganglia infarcts, and brainstem infarcts was 100%, 100%, 100%, 0% (p=0.0022). The sensitivity and Odds ratio of CT/P/A in cerebral infarcts differed according to the diameter of the infarcts. That with infarcts of 10 mm or more was 91%, 20. That with infarcts smaller than 10 mm was 50%, 2. CTA detected arterial lesions that caused cerebral ischemic attack with a sensitivity of 94% and specificity of 90%. The examination time for CT/P/A was 18 minutes, total radiation time being 90 seconds. Although CT/P/A was ineffective for the diagnosis of brainstem infarcts and lesions smaller than 10 mm, CT/P/A was useful in detecting moderate-sized hypoperfusion areas and arterial lesions three-dimensionally before an infarct is completed. (author)

  6. Two- and three-dimensional CT evaluation of sacral and pelvic anomalies

    International Nuclear Information System (INIS)

    Kuhlman, J.E.; Fishman, E.K.; Magid, D.

    1988-01-01

    Pelvic anomalies are difficult to evaluate with standard techniques. Detailed knowledge of the existing pelvic structures and musculature is essential for successful repair. The authors evaluated 12 patients with complex malformations of the pelvis using two- and three-dimensional imaging. The anomalies included bladder exstrophy (n = 4), cloacal exstrophy (n = 1), duplicated and absent sacrum (n = 3), myelomeningoceles (n = 2), and diastrophic dwarfism (n = 2). The two-dimensional images consisted of sequential coronal and sagittal reconstructions that could be reviewed dynamically on screen. Three-dimensional images were generated on the Pixar imaging computer with use of volumetric rendering. Two- and three-dimensional CT proved complementary in the evaluation of pelvic anomalies, providing optimal information from transaxial CT data

  7. Improvement in printing technique of spiral CT three-dimensional colour image

    International Nuclear Information System (INIS)

    Wang Yicheng; Liu Feng; Zhang Ling

    2005-01-01

    Objective: To investigate the printing technique of spiral CT three-dimensional (3D) colour image. Methods: The 3D colour images of 136 patients were printed, with the equipment of Marconi spiral CT, personnel computer, colour ink printer, and network switchboard. Results: All printed images were satisfied by this method. Conclusion: This technique is economic, simple, and useful, and can meet the need for clinical diagnosis and operation. (authors)

  8. Radiation therapy treatment planning: CT, MR imaging and three-dimensional planning

    International Nuclear Information System (INIS)

    Lichter, A.S.

    1987-01-01

    The accuracy and sophistication of radiation therapy treatment planning have increased rapidly in the last decade. Currently, CT-based treatment planning is standard throughout the country. Care must be taken when CT is used for treatment planning because of clear differences between diagnostic scans and scans intended for therapeutic management. The use of CT in radiation therapy planning is discussed and illustrated. MR imaging adds another dimension to treatment planning. The ability to use MR imaging directly in treatment planning involves an additional complex set of capabilities from a treatment planning system. The ability to unwarp the geometrically distorted MR image is a first step. Three-dimensional dose calculations are important to display the dose on sagittal and acoronal sections. The ability to integrate the MR and CT images into a unified radiographic image is critical. CT and MR images are two-dimensional representations of a three-dimensional problem. Through sophisticated computer graphics techniques, radiation therapists are now able to integrate a three-dimensional image of the patient into the treatment planning process. This allows the use of noncoplanar treatment plans and a detailed analysis of tumor and normal tissue anatomy; it is the first step toward a fully conformational treatment planning system. These concepts are illustrated and future research goals outlined

  9. Image-guided stereotactic surgery using ultrasonography and reconstructive three-dimensional CT-imaging system

    International Nuclear Information System (INIS)

    Kawamura, Hirotsune; Iseki, Hiroshi; Umezawa, Yoshihiro

    1991-01-01

    A new simulation and navigation system utilizing three-dimensional CT images has been developed for image-guided stereotactic surgery. Preoperative CT images are not always useful in predicting the intraoperative location of lesions, for cerebral lesions are easily displaced or distorted by gravity, brain retraction, and/or CSF aspiration during operative procedure. This new system, however, has the advantage that the intraoperative locations of intracranial lesions or the anatomical structures of the brain can be precisely confirmed during stereotactic surgery. Serial CT images were obtained from a patient whose head had been fixed to the ISEKI CT-guided stereotactic frame. The data of serial CT images were saved on a floppy disc and then transferred to the work station (IRIS) using the off line. In order to find the best approach angle for ultrasound-guided stereotactic surgery, three-dimenstional CT images were reconstructed using the work station. The site of the craniotomy or the angle of the trajectory of the ultrasound probe was measured preoperatively based on the three-dimensional CT images. Then, in the operating room, the patient's head was fixed to the ISEKI frame with the subframe at the same position as before according to the measurement of the CT images. In a case of cystic glioma, the predicable ultrasonograms from three-dimensional reconstructive CT images were ascertained to correspond well to the actual ultrasound images during ultrasound-guided stereotactic surgery. Therefore, the new simulation and navigation system can be judged to be a powerful operative supporting modality for correcting the locations of cerebral lesions; it allows one to perform stereotactic surgery more accurately and less invasively. (author)

  10. Endoscopic mode for three-dimensional CT display of normal and pathologic laryngeal structures

    International Nuclear Information System (INIS)

    Sanuki, Tetsuji; Hyodo, Masamitsu; Yumoto, Eiji; Yasuhara, Yoshifumi; Ochi, Takashi

    1997-01-01

    The recent development of helical (spiral) computed tomography allows collection of volumetric data to obtain high quality three-dimensional (3D) reconstructed images. The authors applied the 3D CT endoscopic imaging technique to asses normal and pathologic laryngeal structures. The latter included trauma, vocal fold atrophy, cancer of the larynx and recurrent nerve palsy. This technique was able to show normal laryngeal structures and characteristic findings of each pathology. The 3D CT endoscopic images can be rotated around any axis, allowing optimal depiction of pathologic lesion. The use of 3D CT endoscopic technique provides the display of the location and extent of pathology and affords accurate therapeutic planning. (author)

  11. The usefulness of three-dimensional helical CT for the detection of abnormalities of the auditory ossicles

    International Nuclear Information System (INIS)

    Gong, Honghan; Hiraishi, Kumiko; Uesugi, Yasuo; Shimizu, Tadafumi; Narabayashi, Isamu

    1996-01-01

    To evaluate the usefulness of three-dimensional (3D) helical CT for the detection of abnormalities of the auditory ossicles, 3D helical CT of the middle ear was performed in seven patients with hearing disorder. It revealed that 4 patients had congenital deficiency of the auditory ossicles, 2 patients with chronic otitis media had shortening of the incus and one patient with head injury had doubtful fracture of the incus. This study indicated that 3D helical CT of the middle ear can represent the auditory ossicles objectively and can offer detailed diagnosis. (author)

  12. Evaluation of living renal donors: accuracy of three-dimensional 16-section CT

    International Nuclear Information System (INIS)

    Rastogi, N; Sahani, D.V.; Blake, M.A.; Ko, D.C.; Mueller, P.R.

    2006-01-01

    Purpose: To retrospectively assess the sensitivity and specificity of three-dimensional (3D) 16-section computed tomography (CT) in the evaluation of vessels, pelvicalyceal system, and ureters in living renal donors, with surgical findings as the reference standard. Materials and methods: This was a HIPAA-compliant study. Institutional review board approval was obtained for the review of subjects' medical records and data analysis, with waiver of informed consent. Forty-six renal donors (18 men, 28 women; mean age, 42 years) were examined with 16-section CT. Two blinded reviewers independently studied renal vascular and urographic anatomy of each donor CT scans by fist using 3D images alone, then transverse images alone, and finally transverse and 3D data set. Image quality, degree of diagnostic confidence, and time used for review were recorded. Sensitivity and specificity were calculated. Results: For 3D images, transverse images, and transverse in conjunction with 3D data sets, the respective sensitivity and specificity of CT in evaluation of accessory arteries by reviewer 1 were 100% and 100%, 89% and 100%, and 100% and 100%, and those by reviewer 2 were 89% and 97%, 89% and 100%, and 89% and 100%; the respective sensitivity and specificity in evaluation of venous anomalies by reviewer 1 were 100% and 98%, 100% and 98%, and 100% and 98%, and those by reviewer 2 were 100% and 98%, 100% and 95%, and 100% and 98%. For focused comprehensive assessment of renal donors with 3D scans alone, a reviewer on average (average of reviewers 1 and 2) used 2.4 minutes per scan, demonstrated full confidence in 93%, and rated the quality as excellent in 76%. Conclusion: For focused assessment of renal vascular and urographic anatomy, review of 3D data set alone provides high sensitivity and specificity with regard to findings seen at surgery. (author)

  13. Evaluation of living renal donors: accuracy of three-dimensional 16-section CT

    Energy Technology Data Exchange (ETDEWEB)

    Rastogi, N; Sahani, D.V.; Blake, M.A.; Ko, D.C.; Mueller, P.R. [Massachusetts General Hospital, Boston, MA (United States). Dept. of Radiology

    2006-07-15

    Purpose: To retrospectively assess the sensitivity and specificity of three-dimensional (3D) 16-section computed tomography (CT) in the evaluation of vessels, pelvicalyceal system, and ureters in living renal donors, with surgical findings as the reference standard. Materials and methods: This was a HIPAA-compliant study. Institutional review board approval was obtained for the review of subjects' medical records and data analysis, with waiver of informed consent. Forty-six renal donors (18 men, 28 women; mean age, 42 years) were examined with 16-section CT. Two blinded reviewers independently studied renal vascular and urographic anatomy of each donor CT scans by fist using 3D images alone, then transverse images alone, and finally transverse and 3D data set. Image quality, degree of diagnostic confidence, and time used for review were recorded. Sensitivity and specificity were calculated. Results: For 3D images, transverse images, and transverse in conjunction with 3D data sets, the respective sensitivity and specificity of CT in evaluation of accessory arteries by reviewer 1 were 100% and 100%, 89% and 100%, and 100% and 100%, and those by reviewer 2 were 89% and 97%, 89% and 100%, and 89% and 100%; the respective sensitivity and specificity in evaluation of venous anomalies by reviewer 1 were 100% and 98%, 100% and 98%, and 100% and 98%, and those by reviewer 2 were 100% and 98%, 100% and 95%, and 100% and 98%. For focused comprehensive assessment of renal donors with 3D scans alone, a reviewer on average (average of reviewers 1 and 2) used 2.4 minutes per scan, demonstrated full confidence in 93%, and rated the quality as excellent in 76%. Conclusion: For focused assessment of renal vascular and urographic anatomy, review of 3D data set alone provides high sensitivity and specificity with regard to findings seen at surgery. (author)

  14. Determination of optimal parameters for three-dimensional reconstruction images of central airways using helical CT

    International Nuclear Information System (INIS)

    Hirose, Takahumi; Akata, Soichi; Matsuno, Naoto; Nagao, Takeshi; Abe, Kimihiko

    2002-01-01

    Three-dimensional (3D) image reconstruction of central airways using helical CT requires several user-defined parameters that exceed the requirements of conventional CT. The purpose of this study was to evaluate the optimal parameters for 3D images of central airways using helical CT. In our experimental study using a piglet immediately after sacrifice, 3D images of the central airway were evaluated with changes of 3D imaging parameters, such as detector collimation (1, 2, 3 and 6 mm), table speed (1, 2, 3 and 5 mm/sec), tube electric current (50, 100, 150, 200 and 250 mA), reconstruction interval (0.3, 0.5, 1, 2 and 3 mm), algorithm (mediastinum and lung) and interpolation method (180 deg and 360 deg). To minimize detector collimation, table speed, and reconstruction interval could provide the best 3D images of the central airway. Stair-step artifacts could also be reduced with a slow table speed. However, decreasing the collimation and table speed decreases not only the effective section thickness but also the scan coverage that can be achieved with a helical CT. For routine diagnosis, we conclude that optimal parameters for 3D images of the central airway are to minimize the table speed necessary to cover the volume of interest and to set detector collimation to 1/2 of the table speed. The reconstruction intervals should also be selected at up to 1/2 of the detector collimation, but with trade-offs of increased image processing time, data storage requirements, and physician time for image review. Regarding to tube electric current, 200 mA or more was necessary. Pixel noise increased with the algorithm for the lung. The 180 deg interpolation is better than 360 deg interpolation due to thin effective section thickness. (author)

  15. Simulation and experimental studies of three-dimensional (3D) image reconstruction from insufficient sampling data based on compressed-sensing theory for potential applications to dental cone-beam CT

    International Nuclear Information System (INIS)

    Je, U.K.; Lee, M.S.; Cho, H.S.; Hong, D.K.; Park, Y.O.; Park, C.K.; Cho, H.M.; Choi, S.I.; Woo, T.H.

    2015-01-01

    In practical applications of three-dimensional (3D) tomographic imaging, there are often challenges for image reconstruction from insufficient sampling data. In computed tomography (CT), for example, image reconstruction from sparse views and/or limited-angle (<360°) views would enable fast scanning with reduced imaging doses to the patient. In this study, we investigated and implemented a reconstruction algorithm based on the compressed-sensing (CS) theory, which exploits the sparseness of the gradient image with substantially high accuracy, for potential applications to low-dose, high-accurate dental cone-beam CT (CBCT). We performed systematic simulation works to investigate the image characteristics and also performed experimental works by applying the algorithm to a commercially-available dental CBCT system to demonstrate its effectiveness for image reconstruction in insufficient sampling problems. We successfully reconstructed CBCT images of superior accuracy from insufficient sampling data and evaluated the reconstruction quality quantitatively. Both simulation and experimental demonstrations of the CS-based reconstruction from insufficient data indicate that the CS-based algorithm can be applied directly to current dental CBCT systems for reducing the imaging doses and further improving the image quality

  16. Three-dimensional helical (spiral) CT angiography. Visualization of vessels in the maxillofacial regions

    International Nuclear Information System (INIS)

    Hanawa, Shigeo; Sakamoto, Hidetomo; Mori, Shin-ichiro; Kagawa, Toyohiro; Seze, Ryosuke; Ishioka, Hisakazu; Tashiro, Himiko; Ogawa, Kazuhisa; Wada, Tadako

    1998-01-01

    Authors performed the contrast helical CT for tumors on the maxillofacial regions, and reconstituted these data into the three-dimensional helical (spiral) CT angiography (CTA). Furthermore the conditions of photographing and the clinical significance of CTA were discussed. The subjects were 24 cases (including 13 of malignant tumors, 4 of benign tumors, 4 of inflammation and 3 of malformations), to which the contrast helical CT was performed transvenously. The photographing condition was set in principal to 140 kV of the tube voltage, 160 (200) mA of the tube current, 3 mm of the X-ray beam width, 3 mm/sec (pitch=1) of the turn-table moving speed. The relationship between the beam width and the pitch was determined by the phantom experiments. The scanning was carried out maximally for continuous 60 sec as the scanning time of a turn/sec. Of all cases, CTA visualized three-dimensionally vessels, but it was hard in the total carotid arteries and the internal-external carotid arteries. Authors analyzed the axial and the multiplanar reconstitution (MPR) images as the two-dimensional display, and the surface rendering (SR), the volume rendering and the maximum intensity projections (MIP) as the three-dimensional display. The axial and MPR image of the facial arteries and the lingual arteries as the branched vessels from the external carotid arteries were recognized easily. By SR, it was easily to understand the anatomical relationship among vessels, gnathic bone and cervical vertebrae, and by MIP sufficiently observe the concentration dependent calcification of the vessel walls. Three-dimensional CTA is very useful to get the three-dimensional visual information about the anatomical structures of the maxillofacial regions which is necessary for oral surgeons to plan the pre-operational strategies. (K.H.)

  17. Reporducibilities of cephalometric measurements of three-dimensional CT images reconstructed in the personal computer

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Kug Jin; Park, Hyok; Lee, Hee Cheol; Kim, Kee Deog; Park, Chang Seo [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2003-09-15

    The purpose of this study was to report the reproducibility of intra-observer and inter-observer consistency of cephalometric measurements using three-dimensional (3D) computed tomography (CT), and the degree of difference of the cephalometric measurements. CT images of 16 adult patients with normal class I occlusion were sent to personal computer and reconstructed into 3D images using V-Works 3.5{sup TM} (Cybermed Inc., Seoul, Korea). With the internal program of V-Works 3.5{sup TM}, 12 landmarks on regular cephalograms were transformed into 21 analytic categories and measured by 2 observers and in addition, one of the observers repeated their measurements. Intra-observer difference was calculated using paired t-test, and inter-observer by two sample test. There were significant differences in the intra-observer measurements (p<0.05) in four of the categories which included ANS-Me, ANS-PNS, Cdl-GO (Lt), GoL-GoR, but with the exception of Cdl-Go (Lt), ZmL-ZmR, Zyo-Zyo, the average differences were within 2 mm of each other. The inter-observer observations also showed significant differences in the measurements of the ZmL-ZmR and Zyo-Zyo categories (p<0.05). With the exception of the Cdl-Me (Rt), ZmL-ZmR, Zyo-Zyo categories, the average differences between the two observers were within 2mm, but the ZmL-ZmR and Zyo-Zyo values differed greatly with values of 8.10 and 19.8 mm respectively. In general, 3D CT images showed greater accuracy and reproducibility, with the exception of suture areas such as Zm and Zyo, than regular cephalograms in orthodontic measurement, showing differences of less than 2 mm, therefore 3D CT images can be useful in cephalometric measurements and treatment planning.

  18. Virtual reality publication of spiral ct-derived three-dimensional models: or, creation of spiral, CT-derived, three-dimensional VRML objects.

    Science.gov (United States)

    Tyszka, J M

    1997-01-01

    Three-dimensional models can be generated from slice images, such as those obtained from computed tomography (CT) and magnetic resonance imaging (MRI) using a variety of techniques. A popular method for rendering 3D anatomical models is the creation of polygonal mesh surfaces representing the boundary between tissues. Mesh surfaces can be rendered extremely quickly using conventional personal computers, without recourse to more expensive graphic workstations. The dissemination of three-dimensional (3D) models across the Internet has been made significantly easier by the definition of the Virtual Reality Markup Language (VRML) format. The VRML definition allows the parameters and relationships of 3D objects to be described in a text format. The text file can be transfered from a host computer to a remote client computer through the World Wide Web and viewed using readily available software (See Appendix). VRML is based on the definition of primitive 3D objects such as polygons and spheres. Consequently, the transition from a mesh surface derived from a clinical image data set to a VRML object is relatively simple, allowing for convenient and cost-effective dissemination of 3D clinical models across the internet.

  19. Studies on three-dimensional reproduction of maxillofacial cranium shape, 2

    International Nuclear Information System (INIS)

    Mihara, Manabu

    1984-01-01

    The purpose of the serial studies were to develop a three-dimensional reproduction for diagnosis and surgical therapy planning. In the present study, the author devised the methd of making models reproduced through applying high resolutional computed tomography (GE CT/T). Preliminary examinations were carried out on the CT numbers and on the measurement of CT film images for three-dimensional reproduction. The results are summarized below: 1) There were few hourly changes of CT numbers. 2) At the interspace of the phantom teflon rod and water, CT numbers changed gradually because of the partial volume effect and the edge response. Although the true boundaries of the materials could be indentified with the median CT number of the two substances. 3) Setting up to 1,000 on the window level and 1,200 on the window width, the measurement value of the views of the phantom teflon rod which had been magnified 1.8 power coincided with the true size. 4) Supplementary examinations were carried out on the same methods using a pig mandible, and the results were affirmed. The models were made of acrilic boards which the images of CT films were traced. Those boards were waxed up and trimmed in the boxies for three-dimensional reproduction by using cephalograms. The reproducible accuracy of the completed models was satisfactory for use in the field of the maxillofacial surgery. (author)

  20. Color-coded volume rendering for three-dimensional reconstructions of CT data

    International Nuclear Information System (INIS)

    Rieker, O.; Mildenberger, P.; Thelen, M.

    1999-01-01

    Purpose: To evaluate a technique of colored three-dimensional reconstructions without segmentation. Material and methods: Color-coded volume rendered images were reconstructed from the volume data of 25 thoracic, abdominal, musculoskeletal, and vascular helical CT scans using commercial software. The CT volume rendered voxels were encoded with color in the following manner. Opacity, hue, lightness, and chroma were assigned to each of four classes defined by CT number. Color-coded reconstructions were compared to the corresponding grey-scale coded reconstructions. Results: Color-coded volume rendering enabled realistic visualization of pathologic findings when there was sufficient difference in CT density. Segmentation was necessary in some cases to demonstrate small details in a complex volume. Conclusion: Color-coded volume rendering allowed lifelike visualisation of CT volumes without the need of segmentation in most cases. (orig.) [de

  1. Three-dimensional CT diagnosis of myositis ossificans of the sacrospinous ligament

    International Nuclear Information System (INIS)

    Agrons, G.A.; Markowitz, R.I.; Bronson, W.E.

    1993-01-01

    We present the case of a 4-year-old female with a complex fracture of the left hemipelvis who, on follow-up CT imaging, developed new ossific densities within the peripelvic soft tissues of the contralateral side. Three-dimensional surface reformations of the pelvis demonstrated myositis ossificans along the course of the right sacrospinous ligament, thus elucidating unsuspected ligamentous injury and implying prior instability. (orig.)

  2. Three-dimensional CT diagnosis of myositis ossificans of the sacrospinous ligament

    Energy Technology Data Exchange (ETDEWEB)

    Agrons, G.A. (Children' s Hospital of Philadelphia, PA (United States)); Markowitz, R.I. (Children' s Hospital of Philadelphia, PA (United States)); Bronson, W.E. (Children' s Hospital of Philadelphia, PA (United States))

    1993-04-01

    We present the case of a 4-year-old female with a complex fracture of the left hemipelvis who, on follow-up CT imaging, developed new ossific densities within the peripelvic soft tissues of the contralateral side. Three-dimensional surface reformations of the pelvis demonstrated myositis ossificans along the course of the right sacrospinous ligament, thus elucidating unsuspected ligamentous injury and implying prior instability. (orig.)

  3. Three-dimensional image analysis of the skull using variable CT scanning protocols-effect of slice thickness on measurement in the three-dimensional CT images

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Ho Gul; Kim, Kee Deog; Park, Hyok; Kim, Dong Ook; Jeong, Hai Jo; Kim, Hee Joung; Yoo, Sun Kook; Kim, Yong Oock; Park, Chang Seo [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2004-07-15

    To evaluate the quantitative accuracy of three-dimensional (3D) images by mean of comparing distance measurements on the 3D images with direct measurements of dry human skull according to slice thickness and scanning modes. An observer directly measured the distance of 21 line items between 12 orthodontic landmarks on the skull surface using a digital vernier caliper and each was repeated five times. The dry human skull was scanned with a Helical CT with various slice thickness (3, 5, 7 mm) and acquisition modes (Conventional and Helical). The same observer measured corresponding distance of the same items on reconstructed 3D images with the internal program of V-works 4.0 (Cybermed Inc., Seoul, Korea). The quantitative accuracy of distance measurements were statistically evaluated with Wilcoxons' two-sample test. 11 line items in Conventional 3 mm, 8 in Helical 3 mm, 11 in Conventional 5 mm, 10 in Helical 5 mm, 5 in Conventional 7 mm and 9 in Helical 7 mm showed no statistically significant difference. Average difference between direct measurements and measurements on 3D CT images was within 2 mm in 19 line items of Conventional 3 mm. 20 of Helical 3 mm, 15 of Conventional 5 mm, 18 of Helical 5 mm, 11 of Conventional 7 mm and 16 of Helical 7 mm. Considering image quality and patient's exposure time, scanning protocol of Helical 5 mm is recommended for 3D image analysis of the skull in CT.

  4. Dynamic evaluation of pelvic floor reconstructive surgery using radiopaque meshes and three-dimensional helical CT

    Directory of Open Access Journals (Sweden)

    Paulo Palma

    2010-04-01

    Full Text Available PURPOSE: This prospective study was performed to achieve visualization of the reestablishment of anatomy after reconstructive surgery in the different pelvic compartments with non-absorbable radiopaque meshes, providing valuable anatomic information for surgeons implanting meshes. MATERIALS AND METHODS: A total of 30 female patients with stress urinary incontinence (SUI, anterior and posterior vaginal wall prolapse, or both underwent surgical repair using radiopaque meshes after written informed consent. Patients with SUI underwent five different surgeries. Patients with anterior vaginal prolapse underwent a procedure using a combined pre-pubic and transobturator mesh, and those with posterior vaginal prolapse underwent posterior slingplasty. Three-dimensional reconstruction using helical CT was performed four weeks postoperatively. RESULTS: In all cases, the mesh was clearly visualized. Transobturator slings were shown at the midurethra, and the anchoring tails perforated the obturator foramen at the safety region. Mini-slings were in the proper place, and computed angiography revealed that the anchoring system was away from the obturator vessels. In patients undergoing procedure for anterior vaginal prolapse, both pre-pubic armpit and obturator slings were clearly seen and the mesh was in the proper position, supporting the bladder base and occluding the distal part of the urogenital hiatus. Transcoccygeal sacropexy revealed indirectly a well-supported "neo rectovaginal fascia" and the anchoring tails at the level of ischial spines. CONCLUSION: Three-dimensional helical tomography images of the female pelvis using radiopaque meshes have a potential role in improving our understanding of pelvic floor reconstructive surgeries. These radiopaque meshes might be the basis of a new investigative methodology.

  5. Interactive, three dimensional, CT-based treatment planning of stereotaxic I-125 brain implants. 132

    International Nuclear Information System (INIS)

    Lulu, B.; Lewis, J.; Smith, V.; Stuart, A.

    1987-01-01

    Brain implants of I-125 seeds are done with the Brown-Roberts-Wells stereotaxic frame. The patient is CT scanned with the frame bolted to the skull. In the time between the scan and surgery, while the patient is under anesthesia, an interactive three dimensional CT-based treatment plan is performed on a VAX computer. The program is menu driven, easy to use, and easily modifiable. Device dependencies are limited to a small number of subroutines, and an array processor is used to speed dose calculations

  6. Study of three-dimensional effects on vortex breakdown

    Science.gov (United States)

    Salas, M. D.; Kuruvila, G.

    1988-01-01

    The incompressible axisymmetric steady Navier-Stokes equations in primitive variables are used to simulate vortex breakdown. The equations, discretized using a second-order, central-difference scheme, are linearized and then solved using an exact LU decomposition, Gaussian elimination, and Newton iteration. Solutions are presented for Reynolds numbers, based on vortex-core radius, as high as 1500. An attempt to study the stability of the axisymmetric solutions against three-dimensional perturbations is discussed.

  7. SU-F-P-32: A Phantom Study of Accuracy of Four-Dimensional Cone-Beam CT (4D-CBCT) Vs. Three-Dimensional Cone Beam CT (3D-CBCT) in Image Guided Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    He, R; Morris, B; Duggar, N; Markovich, A; Standford, J; Lu, J; Yang, C [University of Mississippi Med. Center, Jackson, MS (United States)

    2016-06-15

    Purpose: SymmetryTM 4D IGRT system of Elekta has been installed at our institution, which offers the 4D CBCT registration option. This study is to evaluate the accuracy of 4D CBCT system by using the CIRS 4D motion phantom and to perform a feasibility study on the implementation of 4D-CBCT as image guidance for SBRT treatment. Methods: The 3D and 4D CT image data sets are acquired using the CIRS motion phantom on a Philips large bore CT simulator. The motion was set as 0.5 cm superior and inferior directions with 6 seconds recycle time. The 4D CT data were sorted as 10 phases. One identifiable part of the 4D CT QA insert from CIRS phantom was used as the target. The ITV MIP was drawn based on maximum intensity projection (MIP) and transferred as a planning structure into 4D CBCT system. Then the 3D CBCT and 4D CBCT images were taken and registered with the free breath (3D), MIP (4D) and average intensity projection (AIP)(4D) reference data sets. The couch shifts (X, Y, Z) are recorded and compared. Results: Table 1 listed the twelve couch shifts based on the registration of MIP, AIP and free breath CT data sets with 3D CBCT and 4D CBCT for both whole body and local registration. X, Y and Z represent couch shifts in the direction of the right-left, superior-inferior and anterior-posterior. The biggest differences of 0.73 cm and 0.57 cm are noted in the free breath CT data with 4D CBCT and 3D CBCT data registration. Fig. 1 and Fig. 2 are the shift analysis in diagram. Fig. 3 shows the registration. Conclusion: Significant differences exist in the shifts corresponding with the direction of target motion. Further investigations are ongoing.

  8. A comparison of primary two- and three-dimensional methods to review CT colonography

    International Nuclear Information System (INIS)

    Gelder, Rogier E. van; Florie, Jasper; Nio, C. Yung; Jager, Steven W. de; Lameris, Johan S.; Stoker, Jaap; Jensch, Sebastiaan; Vos, Frans M.; Venema, Henk W.; Bartelsman, Joep F.; Reitsma, Johannes B.; Bossuyt, Patrick M.M.

    2007-01-01

    The aim of our study was to compare primary three-dimensional (3D) and primary two-dimensional (2D) review methods for CT colonography with regard to polyp detection and perceptive errors. CT colonography studies of 77 patients were read twice by three reviewers, first with a primary 3D method and then with a primary 2D method. Mean numbers of true and false positives, patient sensitivity and specificity and perceptive errors were calculated with colonoscopy as a reference standard. A perceptive error was made if a polyp was not detected by all reviewers. Mean sensitivity for large (≥10 mm) polyps for primary 3D and 2D review was 81% (14.7/18) and 70%(12.7/18), respectively (p-values ≥0.25). Mean numbers of large false positives for primary 3D and 2D were 8.3 and 5.3, respectively. With primary 3D and 2D review 1 and 6 perceptive errors, respectively, were made in 18 large polyps (p = 0.06). For medium-sized (6-9 mm) polyps these values were for primary 3D and 2D, respectively: mean sensitivity: 67%(11.3/17) and 61%(10.3/17; p-values≥ 0.45), number of false positives: 33.3 and 15.6, and perceptive errors: 4 and 6 (p = 0.53). No significant differences were found in the detection of large and medium-sized polyps between primary 3D and 2D review. (orig.)

  9. Multimodal registration of three-dimensional maxillodental cone beam CT and photogrammetry data over time.

    Science.gov (United States)

    Bolandzadeh, N; Bischof, W; Flores-Mir, C; Boulanger, P

    2013-01-01

    In recent years, one of the foci of orthodontics has been on systems for the evaluation of treatment results and the tracking of tissue variations over time. This can be accomplished through analysing three-dimensional orthodontic images obtained before and after the treatments. Since complementary information is achieved by integrating multiple imaging modalities, cone beam CT (CBCT) and stereophotogrammetry technologies are used in this study to develop a method for tracking bone, teeth and facial soft-tissue variations over time. We propose a two-phase procedure of multimodal (Phase 1) and multitemporal (Phase 2) registration which aligns images taken from the same patient by different imaging modalities and at different times. Extrinsic (for Phase 1) and intrinsic (for Phase 2) landmark-based registration methods are employed as an initiation for a robust iterative closest points algorithm. Since the mandible moves independently of the upper skull, the registration procedure is applied separately on the mandible and the upper skull. The results show that the signed error distributions of both mandible and skull registrations follow a mixture of two Gaussian distributions, corresponding to alignment errors (due to our method) and temporal change over time. We suggest that the large values among the total registration errors correspond to the temporal change resulting from (1) the effect of treatment (i.e. the orthodontic changes of teeth positions); (2) the biological changes such as teeth growth over time, especially for teenagers; and (3) the segmentation procedure and CBCT precision change over time.

  10. Three-dimensional patient setup errors at different treatment sites measured by the Tomotherapy megavoltage CT

    Energy Technology Data Exchange (ETDEWEB)

    Hui, S.K.; Lusczek, E.; Dusenbery, K. [Univ. of Minnesota Medical School, Minneapolis, MN (United States). Dept. of Therapeutic Radiology - Radiation Oncology; DeFor, T. [Univ. of Minnesota Medical School, Minneapolis, MN (United States). Biostatistics and Informatics Core; Levitt, S. [Univ. of Minnesota Medical School, Minneapolis, MN (United States). Dept. of Therapeutic Radiology - Radiation Oncology; Karolinska Institutet, Stockholm (Sweden). Dept. of Onkol-Patol

    2012-04-15

    Reduction of interfraction setup uncertainty is vital for assuring the accuracy of conformal radiotherapy. We report a systematic study of setup error to assess patients' three-dimensional (3D) localization at various treatment sites. Tomotherapy megavoltage CT (MVCT) images were scanned daily in 259 patients from 2005-2008. We analyzed 6,465 MVCT images to measure setup error for head and neck (H and N), chest/thorax, abdomen, prostate, legs, and total marrow irradiation (TMI). Statistical comparisons of the absolute displacements across sites and time were performed in rotation (R), lateral (x), craniocaudal (y), and vertical (z) directions. The global systematic errors were measured to be less than 3 mm in each direction with increasing order of errors for different sites: H and N, prostate, chest, pelvis, spine, legs, and TMI. The differences in displacements in the x, y, and z directions, and 3D average displacement between treatment sites were significant (p < 0.01). Overall improvement in patient localization with time (after 3-4 treatment fractions) was observed. Large displacement (> 5 mm) was observed in the 75{sup th} percentile of the patient groups for chest, pelvis, legs, and spine in the x and y direction in the second week of the treatment. MVCT imaging is essential for determining 3D setup error and to reduce uncertainty in localization at all anatomical locations. Setup error evaluation should be performed daily for all treatment regions, preferably for all treatment fractions. (orig.)

  11. Development of an automated extraction method for liver tumors in three dimensional multiphase multislice CT images

    International Nuclear Information System (INIS)

    Nakagawa, Junya; Shimizu, Akinobu; Kobatake, Hidefumi

    2004-01-01

    This paper proposes a tumor detection method using four phase three dimensional (3D) CT images of livers, i.e. non-contrast, early, portal, and late phase images. The method extracts liver regions from the four phase images and enhances tumors in the livers using a 3D adaptive convergence index filter. Then it detects local maximum points and extracts tumor candidates by a region growing method. Subsequently several features of the candidates are measured and each candidate is classified into true tumor or normal tissue based on Mahalanobis distances. Above processes except liver region extraction are applied to four phase images, independently and four resultant images are integrated into one. We applied the proposed method to 3D abdominal CT images of ten patients obtained with multi-detector row CT scanner and confirmed that tumor detection rate was 100% without false positives, which was quite promising results. (author)

  12. Assessment of the usefulness of three-dimensional CT angiography after peripheral arterial bypass surgery

    International Nuclear Information System (INIS)

    Hayashi, Saihou; Sasaki, Masaru; Kawamoto, Jun

    1997-01-01

    Conventional CT and three-dimensional CT angiography (3D-CTA) were conducted after peripheral arterial bypass surgery on 17 patients (26 grafts) from October, 1994 to April, 1996. Seventeen grafts were patent. The following objectives were satisfied in these cases: 1. Prosthetic graft or saphenous vein was depicted by 3D-CTA, 2. The distal portion of the native artery was depicted by 3D-CTA, and 3. Opacification of the graft interior was recognized by transverse section of CT. Nine grafts were occluded but prosthetic grafts were depicted in 5 cases, and prosthetic grafts and the distal portions of native arteries in 3 cases. Opacification of the graft interior was not seen in any case. Achievement of the above three objectives was considered necessary to determine graft patency. (author)

  13. The interpolation method based on endpoint coordinate for CT three-dimensional image

    International Nuclear Information System (INIS)

    Suto, Yasuzo; Ueno, Shigeru.

    1997-01-01

    Image interpolation is frequently used to improve slice resolution to reach spatial resolution. Improved quality of reconstructed three-dimensional images can be attained with this technique as a result. Linear interpolation is a well-known and widely used method. The distance-image method, which is a non-linear interpolation technique, is also used to convert CT value images to distance images. This paper describes a newly developed method that makes use of end-point coordinates: CT-value images are initially converted to binary images by thresholding them and then sequences of pixels with 1-value are arranged in vertical or horizontal directions. A sequence of pixels with 1-value is defined as a line segment which has starting and end points. For each pair of adjacent line segments, another line segment was composed by spatial interpolation of the start and end points. Binary slice images are constructed from the composed line segments. Three-dimensional images were reconstructed from clinical X-ray CT images, using three different interpolation methods and their quality and processing speed were evaluated and compared. (author)

  14. Three-dimensional C-arm CT-guided transjugular intrahepatic portosystemic shunt placement: Feasibility, technical success and procedural time

    Energy Technology Data Exchange (ETDEWEB)

    Ketelsen, Dominik; Groezinger, Gerd; Maurer, Michael; Grosse, Ulrich; Horger, Marius; Nikolaou, Konstantin; Syha, Roland [University of Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Lauer, Ulrich M. [University of Tuebingen, Internal Medicine I, Department of Gastroenterology, Hepatology and Infectious disease, Tuebingen (Germany)

    2016-12-15

    Establishment of transjugular intrahepatic portosystemic shunts (TIPS) constitutes a standard procedure in patients suffering from portal hypertension. The most difficult step in TIPS placement is blind puncture of the portal vein. This study aimed to evaluate three-dimensional mapping of portal vein branches and targeted puncture of the portal vein. Twelve consecutive patients suffering from refractory ascites by liver cirrhosis were included in this retrospective study to evaluate feasibility, technical success and procedural time of C-arm CT-targeted puncture of the portal vein. As a control, 22 patients receiving TIPS placement with fluoroscopy-guided blind puncture were included to compare procedural time. Technical success could be obtained in 100 % of the study group (targeted puncture) and in 95.5 % of the control group (blind puncture). Appropriate, three-dimensional C-arm CT-guided mapping of the portal vein branches could be achieved in all patients. The median number of punctures in the C-arm CT-guided study group was 2 ± 1.3 punctures. Procedural time was significantly lower in the study group (14.8 ± 8.2 min) compared to the control group (32.6 ± 22.7 min) (p = 0.02). C-arm CT-guided portal vein mapping is technically feasible and a promising tool for TIPS placement resulting in a significant reduction of procedural time. (orig.)

  15. Volume-editing tools for three-dimensional imaging of CT data

    International Nuclear Information System (INIS)

    Ney, D.R.; Fishman, E.K.

    1989-01-01

    Three-dimensional imaging of complex structures relies heavily on the ability to edit the routine CT scans to provide an optimal view of the area in question. The authors present a series of strategies for defining the volume editing tools. The authors have developed a series of editing tools that allow the operator to edit critical areas out of an image. The tools are based on a variety of imaging strategies that are implemented depending on the difficulty of separating two structures. The tools combine rectangular masking, threshold base filling, arbitrary curve-based masking, masking, threshold base filling, arbitrary curve-based masking, and object definition via edge detection

  16. Three-dimensional CT angiography in the diagnosis of cerebrovascular disease

    International Nuclear Information System (INIS)

    Eguchi, Takahiko; Nikaido, Yuji; Nakamura, Takeshi; Yoneda, Shigeru

    1995-01-01

    We reported the usefulness of three dimensional CT angiography (3 DCTA) in cerebrovascular disease. Twenty two of twenty three intracerebral aneurysms were visualized in 3 DCTA. 3 DTPA was especially useful for the evaluation of posterior-projection anterior communicating arteries and the distinction between a carotid-posterior communicating aneurysm and an infundibular dilatation. An anterior-projection carotid bifurcation aneurysm, which we missed in DSA, was visualized clearly in 3 DCTA. Stenotic cervical carotid artery lesions were well evaluated in 3 DCTA, including ulceration. 3 DCTA was not so useful for evaluation of intracranial artery stenosis. 3 DCTA was useful as a non-invasive method to evaluate cerebrovascular diseases. (author)

  17. Endoscopic visualization of luminal organ and great vessels with three dimensional CT scanner

    International Nuclear Information System (INIS)

    Kobayashi, Hisashi; Okumura, Toshiyuki; Amemiya, Ryuta; Hasegawa, Hiroshi

    1992-01-01

    Thirty cases examined by three dimensional CT scanner (3DCT) are reported. The observation of inner view using 3DCT were performed in 12 large vessels with vascular disorder, 10 pulmonary bronchi with lung cancer and 8 common bile ducts involved obstructive disease. In order to visualize interface of the lumen, a new software, which was developed by HITACHI MEDICO Inc., was used. In all cases but one the inner view of the luminal organ was clearly demonstrated as 3D images and it was possible to judge some changes of luminal interface involved by the diseases. The 3DCT endoscopic image might be useful as a new endoscopic technique without fiberscopy. (author)

  18. The use of a neuronavigator in combination with three-dimensional CT reconstruction and angiography

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Eiju; Mayanagi, Yoshiaki (Tokyo Metropolitan Police Hospital (Japan)); Ishii, Shigeo; Yoshimoto, Satonobu; Takakura, Kintomo

    1989-08-01

    A new CT-stereotactic device (navigator) has been developed which translates the operating site into preoperative CT coordination. We applied this system in combination with three-dimensional CT reconstruction and with angiogram. Method: The system consists of a 6-joint robotic arm and a personal computer. It projects the location of the arm tip onto a correlating CT slice with a cursor, which guides a surgeon toward his intracranial target during open surgery. The system translates the tip location into a 3D-CT reconstructed image and an angiogram. The system worked as the core of a multimodality navigation system during surgery. The detection error was less than 5 mm, which proved sufficient for open microsurgery. The system was combined with a 3D-CT reconstruction system. It produces 3D images and cuts off the surface image at the point of the cursor, simulating surgical excision. The navigator controlled the location of the cutting cursor, thus establishing a real-time surgical simulation. When the angiogram was referred to, it became easy to identify bridging veins within a small operating field. Conclusion: The neuronavigator combines various diagnostic images into one data base and effectively guides the surgeon during surgery. (author).

  19. The use of a neuronavigator in combination with three-dimensional CT reconstruction and angiography

    International Nuclear Information System (INIS)

    Watanabe, Eiju; Mayanagi, Yoshiaki; Ishii, Shigeo; Yoshimoto, Satonobu; Takakura, Kintomo.

    1989-01-01

    A new CT-stereotactic device (navigator) has been developed which translates the operating site into preoperative CT coordination. We applied this system in combination with three-dimensional CT reconstruction and with angiogram. Method: The system consists of a 6-joint robotic arm and a personal computer. It projects the location of the arm tip onto a correlating CT slice with a cursor, which guides a surgeon toward his intracranial target during open surgery. The system translates the tip location into a 3D-CT reconstructed image and an angiogram. The system worked as the core of a multimodality navigation system during surgery. The detection error was less than 5 mm, which proved sufficient for open microsurgery. The system was combined with a 3D-CT reconstruction system. It produces 3D images and cuts off the surface image at the point of the cursor, simulating surgical excision. The navigator controlled the location of the cutting cursor, thus establishing a real-time surgical simulation. When the angiogram was referred to, it became easy to identify bridging veins within a small operating field. Conclusion: The neuronavigator combines various diagnostic images into one data base and effectively guides the surgeon during surgery. (author)

  20. High-resolution three-dimensional visualization of the rat spinal cord microvasculature by synchrotron radiation micro-CT

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Jianzhong; Cao, Yong; Wu, Tianding; Li, Dongzhe [Department of Spine Surgery, Xiangya Hospital, Central South University, Changsha 410008 (China); Lu, Hongbin, E-mail: hongbinlu@hotmail.com [Department of Sports Medicine, Research Centre of Sports Medicine, Xiangya Hospital, Central South University, Changsha 410008 (China)

    2014-10-15

    Purpose: Understanding the three-dimensional (3D) morphology of the spinal cord microvasculature has been limited by the lack of an effective high-resolution imaging technique. In this study, synchrotron radiation microcomputed tomography (SRµCT), a novel imaging technique based on absorption imaging, was evaluated with regard to the detection of the 3D morphology of the rat spinal cord microvasculature. Methods: Ten Sprague-Dawley rats were used in this ex vivo study. After contrast agent perfusion, their spinal cords were isolated and scanned using conventional x-rays, conventional micro-CT (CµCT), and SRµCT. Results: Based on contrast agent perfusion, the microvasculature of the rat spinal cord was clearly visualized for the first time ex vivo in 3D by means of SRµCT scanning. Compared to conventional imaging techniques, SRµCT achieved higher resolution 3D vascular imaging, with the smallest vessel that could be distinguished approximately 7.4 μm in diameter. Additionally, a 3D pseudocolored image of the spinal cord microvasculature was generated in a single session of SRµCT imaging, which was conducive to detailed observation of the vessel morphology. Conclusions: The results of this study indicated that SRµCT scanning could provide higher resolution images of the vascular network of the spinal cord. This modality also has the potential to serve as a powerful imaging tool for the investigation of morphology changes in the 3D angioarchitecture of the neurovasculature in preclinical research.

  1. Three-dimensional image display by CT data processing and clinical applications in orthopaedics and craniofacial surgery

    International Nuclear Information System (INIS)

    Zonneveld, F.W.; Akkerveeken, P.F. van; Koornneef, L.

    1988-01-01

    The methods of generating three-dimensional images from two-dimensional CT data are described. Four cases are reported explaining its use in the planning of orthopaedic and craniofacial surgery. (orig.) [de

  2. Preoperative cerebral aneurysm assessment by three-dimensional CT angiography. Feasibility of surgery without cerebral angiography

    International Nuclear Information System (INIS)

    Kashiwagi, Shiro; Yamashita, Katsuhiro; Kato, Shoichi; Ito, Haruhide; Kurokawa, Kensuke; Watanabe, Yutaka

    1999-01-01

    The purpose of this study is to assess the capability of three-dimensional CT angiography (3D-CTA) to replace conventional catheter angiography as a preoperative examination for unruptured intracranial aneurysms. A prospective study was designed to evaluate 18 patients with 20 unruptured intracranial aneurysms (13 middle cerebral artery aneurysms, 6 anterior communicating artery aneurysms, and 1 internal carotid posterior communicating artery aneurysm) who underwent surgery. There were 12 women and 6 men with the average age of 63 years old. All patients were initially diagnosed as having intracranial aneurysms by MR angiography, followed by 3D-CTA and conventional catheter angiography for confirmation. Three experienced neurosurgeons were in charge of the operations. One of the neurosurgeons (surgeon 1) was provided with only 3D-CTA as the preoperative radiological evaluation, while the others (surgeon 2 and 3) were given through assessments with MRA, 3D-CTA, and conventional angiography. Surgeon 1 carried out the operations under careful observation by the surgeons 2 and 3. Problems encountered by the surgeon 1 during surgery were recorded. Neck clipping in 19 aneurysms and dome wrapping in 1 were successfully accomplished. All patients were discharged without complication. Surgeries went smoothly in 16 aneurysms with 3D-CTA alone. Discrepancies between the 3D-CTA findings and microsurgical anatomy were noted in 4 aneurysms: the size of the neck was overestimated in 3 aneurysms, the relationships to parent arteries were obscure in 2 aneurysms, and a perforating artery problematic to neck clipping was missed in 1 aneurysms by 3D-CTA. The results of this study support the notion that 3D-CTA can replace conventional catheter angiography as preoperative examination in the majority of regular-sized anterior circulation aneurysms. Nevertheless, surgeons should recognize and be prepared for the fact that 3D-CTA can give false impression about the aneurysm neck and

  3. Clinical application of three-dimensional imaging with multislice CT for laparoscopic colorectal surgery

    International Nuclear Information System (INIS)

    Matsuki, Mitsuru; Okuda, Jyunji; Yoshikawa, Syushi

    2003-01-01

    Laparoscopic colorectal surgery, while minimally invasive, is a complicated technique. Therefore, prior to this surgery, it is important to determine the anatomical information of colorectal cancer. Fifty-eight cases of patients with a confirmed diagnosis of colon cancer [caecal (n=4), ascending colon (n=6), transverse colon (n=7), descending colon (n=2), sigmoid colon (n=22), and rectal (n=17) cancer] were evaluated using multislice CT before laparoscopic surgery. CT examination was performed in an air-filled colorectum by colon fiberscopy. Contrast-enhanced images on multislice CT were obtained at arterial and venous phases. All images were reviewed on a workstation, and three-dimensional (3D) images of vessels, colorectum, cancer, and swollen lymph nodes were reconstructed by volume rendering and fused (integrated 3D imaging). We evaluated the usefulness of integrated 3D imaging with multislice CT for laparoscopic colorectal surgery. Integrated 3D imaging demonstrated clearly the distribution of arteries feeding the colorectal cancer and the anatomical location of colorectal cancer and arterial and venous systems. Moreover, measurement of the distance between the aortic bifurcation and the origin of the inferior mesenteric artery and that between the base of the inferior mesenteric artery and the origin of the left colic artery on integrated 3D imaging contributed to safe, prompt ligation of the vessels and excision of lymph nodes. Integrated 3D imaging with multislice CT was useful for simulation of laparoscopic colorectal surgery. (author)

  4. Clinical application of three-dimensional imaging with multislice CT for laparoscopic colorectal surgery

    Energy Technology Data Exchange (ETDEWEB)

    Matsuki, Mitsuru; Okuda, Jyunji; Yoshikawa, Syushi [Osaka Medical Coll., Takatsuki (Japan)] (and others)

    2003-03-01

    Laparoscopic colorectal surgery, while minimally invasive, is a complicated technique. Therefore, prior to this surgery, it is important to determine the anatomical information of colorectal cancer. Fifty-eight cases of patients with a confirmed diagnosis of colon cancer [caecal (n=4), ascending colon (n=6), transverse colon (n=7), descending colon (n=2), sigmoid colon (n=22), and rectal (n=17) cancer] were evaluated using multislice CT before laparoscopic surgery. CT examination was performed in an air-filled colorectum by colon fiberscopy. Contrast-enhanced images on multislice CT were obtained at arterial and venous phases. All images were reviewed on a workstation, and three-dimensional (3D) images of vessels, colorectum, cancer, and swollen lymph nodes were reconstructed by volume rendering and fused (integrated 3D imaging). We evaluated the usefulness of integrated 3D imaging with multislice CT for laparoscopic colorectal surgery. Integrated 3D imaging demonstrated clearly the distribution of arteries feeding the colorectal cancer and the anatomical location of colorectal cancer and arterial and venous systems. Moreover, measurement of the distance between the aortic bifurcation and the origin of the inferior mesenteric artery and that between the base of the inferior mesenteric artery and the origin of the left colic artery on integrated 3D imaging contributed to safe, prompt ligation of the vessels and excision of lymph nodes. Integrated 3D imaging with multislice CT was useful for simulation of laparoscopic colorectal surgery. (author)

  5. Three dimensional CT angiography (3D-CTA) in ruptured aneurysm surgery on acute stage

    International Nuclear Information System (INIS)

    Matsumoto, Masato; Endo, Yuji; Nakano, Masayuki

    1998-01-01

    We evaluated three-dimensional CT angiography (3D-CTA) for the treatment of acutely ruptured cerebral aneurysms. Sixty patients with subarachnoid hemorrhage from cerebral aneurysms were investigated both by 3D-CTA and conventional angiography and 26 patients were studied using 3D-CTA without conventional angiography. In the 60 cases, both 3D-CTA and the conventional angiography revealed 100% accuracy in diagnosing ruptured aneurysms, and 3D-CTA and the conventional angiography showed 96% and 92% accuracy for unruptured aneurysms respectively. 3D-CTA was equal or superior to the conventional angiography. Based on these data, since December, 1996, we have operated on 26 consecutive patients with ruptured aneurysms located in the anterior circulation of the circle of Willis, using 3D-CTA without conventional angiography. Thirty-one aneurysms, including 5 associated unruptured aneurysms, were visualized by 3D-CTA and verified at surgery. All aneurysms were clipped successfully. We think that it will be possible to operate on most ruptured aneurysms using only 3D-CTA without the conventional angiography except for the cases of the following situations: if a cerebral infarction is present, conventional angiography is required to evaluate for a stenotic or occlusive lesion of the intracranial arteries, cervical carotid, or vertebral arteries; in cases of giant or large aneurysms, the dynamic information provided by the conventional angiography is needed in case bypass surgery is necessary; and for aneurysms close to bony structures, such as an internal carotid-ophthalmic artery aneurysm, conventional angiography is necessary. (author)

  6. Three-dimensional analysis of mesiobuccal root canal of Japanese maxillary first molar using Micro-CT

    International Nuclear Information System (INIS)

    Yamada, Masashi; Ide, Yoshinobu; Matsunaga, Satoru; Kato, Hiroshi; Nakagawa, Kan-Ichi

    2011-01-01

    The objective of this study was to three-dimensionally observe the morphological characteristics of mesiobuccal root canals of Japanese maxillary first molars using microcomputed tomography (Micro-CT) and classify root canal variations. This study used 90 maxillary first molars. Three-dimensional reconstruction was performed using data obtained by Micro-CT, and cross-sections of the root canals were observed. Moreover, the root canal morphology was classified by the configuration and root canal diameter, and was evaluated for occurrence using the classification by Weine et al. (1969) as a reference. Overall, single root canals were observed in 44.4%, incomplete separation root canals in 22.3%, and completely separate root canals (upper and lower separation root canals) in 33.3%. Mesiobuccal root canals often had intricate configurations, and accessory root canals (lateral canals and apical ramifications) were observed in most of the mesiobuccal root canals (76.7%), irrespective of whether there were ramifications of the main root canals. While there were no marked differences in the incidence of root canal ramifications between this study and earlier reports, the incidence of accessory root canals was higher in this study. This result may be explained by the far more superior visualization ability of Micro-CT than conventional methods, which allowed the detection of microscopic apical ramifications previously difficult to observe. (author)

  7. Propagation of aortic dissection and visceral artery compromise. Three-dimensional analysis on CT angiography

    International Nuclear Information System (INIS)

    Minamiguchi, Hiroki

    2003-01-01

    artery were significant factors to explain the difference. Three-dimensional analysis using CT angiography was essential to understand the propagation of aortic dissection and visceral artery compromise. (author)

  8. Three-dimensional anisotropic adaptive filtering of projection data for noise reduction in cone beam CT

    Energy Technology Data Exchange (ETDEWEB)

    Maier, Andreas; Wigstroem, Lars; Hofmann, Hannes G.; Hornegger, Joachim; Zhu Lei; Strobel, Norbert; Fahrig, Rebecca [Department of Radiology, Stanford University, Stanford, California 94305 (United States); Department of Radiology, Stanford University, Stanford, California 94305 (United States) and Center for Medical Image Science and Visualization, Linkoeping University, Linkoeping (Sweden); Pattern Recognition Laboratory, Department of Computer Science, Friedrich-Alexander University of Erlangen-Nuremberg, 91054, Erlangen (Germany); Nuclear and Radiological Engineering and Medical Physics Programs, George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332 (United States); Siemens AG Healthcare, Forchheim 91301 (Germany); Department of Radiology, Stanford University, Stanford, California 94305 (United States)

    2011-11-15

    Purpose: The combination of quickly rotating C-arm gantry with digital flat panel has enabled the acquisition of three-dimensional data (3D) in the interventional suite. However, image quality is still somewhat limited since the hardware has not been optimized for CT imaging. Adaptive anisotropic filtering has the ability to improve image quality by reducing the noise level and therewith the radiation dose without introducing noticeable blurring. By applying the filtering prior to 3D reconstruction, noise-induced streak artifacts are reduced as compared to processing in the image domain. Methods: 3D anisotropic adaptive filtering was used to process an ensemble of 2D x-ray views acquired along a circular trajectory around an object. After arranging the input data into a 3D space (2D projections + angle), the orientation of structures was estimated using a set of differently oriented filters. The resulting tensor representation of local orientation was utilized to control the anisotropic filtering. Low-pass filtering is applied only along structures to maintain high spatial frequency components perpendicular to these. The evaluation of the proposed algorithm includes numerical simulations, phantom experiments, and in-vivo data which were acquired using an AXIOM Artis dTA C-arm system (Siemens AG, Healthcare Sector, Forchheim, Germany). Spatial resolution and noise levels were compared with and without adaptive filtering. A human observer study was carried out to evaluate low-contrast detectability. Results: The adaptive anisotropic filtering algorithm was found to significantly improve low-contrast detectability by reducing the noise level by half (reduction of the standard deviation in certain areas from 74 to 30 HU). Virtually no degradation of high contrast spatial resolution was observed in the modulation transfer function (MTF) analysis. Although the algorithm is computationally intensive, hardware acceleration using Nvidia's CUDA Interface provided an 8

  9. Measurement of acetabular morphology under three-dimensional reconstruction of CT and significance

    International Nuclear Information System (INIS)

    Han Yingying; Yang Qiwei; Lai Ying; Hao Shuang; Ma Hecheng; Xiao Chengshuang; Li Youqiong

    2011-01-01

    Objective: To measure the acetabular morphology of Chinese on CT three-dimensional (3D) reconstruction image, and provide the evidence on the prevention and treatment of hip disease. Methods: 96 cases (192 sides) of adult hip CT scans were reconstructed, the acetabular index (AA), center-edge (CE), ACE angle, anteversion angle (AVA), abduction angle (ABA), and vertical diameter (SID) were measured. Results: The total acetabular index was (8.78±5.34)°, of which male was (7.84±5.55)° and female was (9.60±5.06)°. The total CE was (33.59±5.91)°, of which male was (34.55±6.03)° and female was (32.78±5.70)°. The total ACE angle was (29.01±5.65)°, of which male was (28.02±5.94)° and female was (29.80±5.30)°. The total AVA was (20.92±5.55)°, of which male was (20.48±5.08)° and female was (21.25±5.89)°. The total ABA was (51.27±4.16)°, of which male was (51.71±4.37)° and female was (50.89±3.96)°. The total SID was (53.79±3.92) mm, of which male was (56.55±2.64) mm and female was (51.46±3.25) mm. Of the above data, there were statistical differences in the acetabular index, CE angle, ACE angle and acetabular diameter between men and women (P<0.05), Chinese and foreigners (P<0.05). While there was no statistical difference between the left and right sides (P>0.05). Conclusion: There are differences in acetabular morphology between men and women, Chinese and foreigners. Compared with simply using overseas data, it is better to study morphological parameters of native acetabula to instruct the preoperative preparation and operation of national total hip arthroplasty surgery. And it is meaningful to design national parameters. (authors)

  10. Three-dimensional anisotropic adaptive filtering of projection data for noise reduction in cone beam CT

    International Nuclear Information System (INIS)

    Maier, Andreas; Wigstroem, Lars; Hofmann, Hannes G.; Hornegger, Joachim; Zhu Lei; Strobel, Norbert; Fahrig, Rebecca

    2011-01-01

    Purpose: The combination of quickly rotating C-arm gantry with digital flat panel has enabled the acquisition of three-dimensional data (3D) in the interventional suite. However, image quality is still somewhat limited since the hardware has not been optimized for CT imaging. Adaptive anisotropic filtering has the ability to improve image quality by reducing the noise level and therewith the radiation dose without introducing noticeable blurring. By applying the filtering prior to 3D reconstruction, noise-induced streak artifacts are reduced as compared to processing in the image domain. Methods: 3D anisotropic adaptive filtering was used to process an ensemble of 2D x-ray views acquired along a circular trajectory around an object. After arranging the input data into a 3D space (2D projections + angle), the orientation of structures was estimated using a set of differently oriented filters. The resulting tensor representation of local orientation was utilized to control the anisotropic filtering. Low-pass filtering is applied only along structures to maintain high spatial frequency components perpendicular to these. The evaluation of the proposed algorithm includes numerical simulations, phantom experiments, and in-vivo data which were acquired using an AXIOM Artis dTA C-arm system (Siemens AG, Healthcare Sector, Forchheim, Germany). Spatial resolution and noise levels were compared with and without adaptive filtering. A human observer study was carried out to evaluate low-contrast detectability. Results: The adaptive anisotropic filtering algorithm was found to significantly improve low-contrast detectability by reducing the noise level by half (reduction of the standard deviation in certain areas from 74 to 30 HU). Virtually no degradation of high contrast spatial resolution was observed in the modulation transfer function (MTF) analysis. Although the algorithm is computationally intensive, hardware acceleration using Nvidia's CUDA Interface provided an 8.9-fold

  11. 4 T MRI of chondrocalcinosis in combination with three-dimensional CT, radiography, and arthroscopy: a report of three cases

    International Nuclear Information System (INIS)

    Suan, J.C.; Chhem, R.K.; Gati, J.S.; Norley, C.J.; Holdsworth, D.W.

    2005-01-01

    To describe 4 T MRI techniques in imaging chondrocalcinosis within the knee and examine the results together with those demonstrated using three-dimensional (3D) computed tomography, conventional radiography, and arthroscopy. From a larger clinical imaging study of early osteoarthritis, knee arthroscopy patients were imaged using high-field MRI and high-resolution 3D CT prior to their surgery. Retrospective review of the imaging data diagnosed three patients with chondrocalcinosis. Fat-suppressed 3D spoiled gradient (3D SPGR) and two-dimensional fat-suppressed fast spin echo (FSE) imaging was performed at 4 T. The MR images, multi-planar reformatted CT (MPR-CT) and maximum intensity projection CT (MIP-CT) images, and radiographs were examined by a musculoskeletal radiologist for the presence and location of chondrocalcinosis. The findings from arthroscopy were also included. MRI showed 16 sites of punctate hypointense regions from 18 articular surfaces and five of six menisci with similar signal characteristics. Both meniscal chondrocalcinosis and meniscal tears were clearly visible using the 3D SPGR sequence. Only three sites were demonstrated to have calcification using MPR-CT and MIP-CT revealed an additional three. In articular cartilage surfaces showing surface disruption, arthroscopy demonstrated 11 sites with crystal deposition. Arthroscopy also revealed five menisci with calcification present. Our preliminary findings suggest that imaging chondrocalcinosis using spoiled gradient 4 T MRI is superior and complementary to the other imaging modalities in the detection of crystal deposition in both articular cartilage and menisci. (orig.)

  12. 4 T MRI of chondrocalcinosis in combination with three-dimensional CT, radiography, and arthroscopy: a report of three cases

    Energy Technology Data Exchange (ETDEWEB)

    Suan, J.C.; Chhem, R.K.; Gati, J.S.; Norley, C.J.; Holdsworth, D.W. [Robarts Research Institute, Imaging Research Laboratories, London, Ontario (Canada)

    2005-11-01

    To describe 4 T MRI techniques in imaging chondrocalcinosis within the knee and examine the results together with those demonstrated using three-dimensional (3D) computed tomography, conventional radiography, and arthroscopy. From a larger clinical imaging study of early osteoarthritis, knee arthroscopy patients were imaged using high-field MRI and high-resolution 3D CT prior to their surgery. Retrospective review of the imaging data diagnosed three patients with chondrocalcinosis. Fat-suppressed 3D spoiled gradient (3D SPGR) and two-dimensional fat-suppressed fast spin echo (FSE) imaging was performed at 4 T. The MR images, multi-planar reformatted CT (MPR-CT) and maximum intensity projection CT (MIP-CT) images, and radiographs were examined by a musculoskeletal radiologist for the presence and location of chondrocalcinosis. The findings from arthroscopy were also included. MRI showed 16 sites of punctate hypointense regions from 18 articular surfaces and five of six menisci with similar signal characteristics. Both meniscal chondrocalcinosis and meniscal tears were clearly visible using the 3D SPGR sequence. Only three sites were demonstrated to have calcification using MPR-CT and MIP-CT revealed an additional three. In articular cartilage surfaces showing surface disruption, arthroscopy demonstrated 11 sites with crystal deposition. Arthroscopy also revealed five menisci with calcification present. Our preliminary findings suggest that imaging chondrocalcinosis using spoiled gradient 4 T MRI is superior and complementary to the other imaging modalities in the detection of crystal deposition in both articular cartilage and menisci. (orig.)

  13. Three-dimensional appearance of the lips muscles with three-dimensional isotropic MRI: in vivo study

    Energy Technology Data Exchange (ETDEWEB)

    Olszewski, Raphael; Reychler, H. [Universite Catholique de Louvain, Department of Oral and Maxillofacial Surgery, Cliniques Universitaires Saint Luc, Brussels (Belgium); Liu, Y.; Xu, T.M. [Peking University School and Hospital of Stomatology, Department of Orthodontics, Beijing (China); Duprez, T. [Universite Catholique de Louvain, Department of Radiology, Cliniques Universitaires Saint Luc, Brussels (Belgium)

    2009-06-15

    Our knowledge of facial muscles is based primarily on atlases and cadaveric studies. This study describes a non-invasive in vivo method (3D MRI) for segmenting and reconstructing facial muscles in a three-dimensional fashion. Three-dimensional (3D), T1-weighted, 3 Tesla, isotropic MRI was applied to a subject. One observer performed semi-automatic segmentation using the Editor module from the 3D Slicer software (Harvard Medical School, Boston, MA, USA), version 3.2. We were able to successfully outline and three-dimensionally reconstruct the following facial muscles: pars labialis orbicularis oris, m. levatro labii superioris alaeque nasi, m. levator labii superioris, m. zygomaticus major and minor, m. depressor anguli oris, m. depressor labii inferioris, m. mentalis, m. buccinator, and m. orbicularis oculi. 3D reconstruction of the lip muscles should be taken into consideration in order to improve the accuracy and individualization of existing 3D facial soft tissue models. More studies are needed to further develop efficient methods for segmentation in this field. (orig.)

  14. Three-dimensional appearance of the lips muscles with three-dimensional isotropic MRI: in vivo study.

    Science.gov (United States)

    Olszewski, Raphael; Liu, Y; Duprez, T; Xu, T M; Reychler, H

    2009-06-01

    Our knowledge of facial muscles is based primarily on atlases and cadaveric studies. This study describes a non-invasive in vivo method (3D MRI) for segmenting and reconstructing facial muscles in a three-dimensional fashion. Three-dimensional (3D), T1-weighted, 3 Tesla, isotropic MRI was applied to a subject. One observer performed semi-automatic segmentation using the Editor module from the 3D Slicer software (Harvard Medical School, Boston, MA, USA), version 3.2. We were able to successfully outline and three-dimensionally reconstruct the following facial muscles: pars labialis orbicularis oris, m. levatro labii superioris alaeque nasi, m. levator labii superioris, m. zygomaticus major and minor, m. depressor anguli oris, m. depressor labii inferioris, m. mentalis, m. buccinator, and m. orbicularis oculi. 3D reconstruction of the lip muscles should be taken into consideration in order to improve the accuracy and individualization of existing 3D facial soft tissue models. More studies are needed to further develop efficient methods for segmentation in this field.

  15. Three-dimensional contrasted visualization of pancreas in rats using clinical MRI and CT scanners.

    Science.gov (United States)

    Yin, Ting; Coudyzer, Walter; Peeters, Ronald; Liu, Yewei; Cona, Marlein Miranda; Feng, Yuanbo; Xia, Qian; Yu, Jie; Jiang, Yansheng; Dymarkowski, Steven; Huang, Gang; Chen, Feng; Oyen, Raymond; Ni, Yicheng

    2015-01-01

    The purpose of this work was to visualize the pancreas in post-mortem rats with local contrast medium infusion by three-dimensional (3D) magnetic resonance imaging (MRI) and computed tomography (CT) using clinical imagers. A total of 16 Sprague Dawley rats of about 300 g were used for the pancreas visualization. Following the baseline imaging, a mixed contrast medium dye called GadoIodo-EB containing optimized concentrations of Gd-DOTA, iomeprol and Evens blue was infused into the distally obstructed common bile duct (CBD) for post-contrast imaging with 3.0 T MRI and 128-slice CT scanners. Images were post-processed with the MeVisLab software package. MRI findings were co-registered with CT scans and validated with histomorphology, with relative contrast ratios quantified. Without contrast enhancement, the pancreas was indiscernible. After infusion of GadoIodo-EB solution, only the pancreatic region became outstandingly visible, as shown by 3D rendering MRI and CT and proven by colored dissection and histological examinations. The measured volume of the pancreas averaged 1.12 ± 0.04 cm(3) after standardization. Relative contrast ratios were 93.28 ± 34.61% and 26.45 ± 5.29% for MRI and CT respectively. We have developed a multifunctional contrast medium dye to help clearly visualize and delineate rat pancreas in situ using clinical MRI and CT scanners. The topographic landmarks thus created with 3D demonstration may help to provide guidelines for the next in vivo pancreatic MRI research in rodents. Copyright © 2015 John Wiley & Sons, Ltd.

  16. Three-dimensional CT examination of the mastication system in the giant anteater.

    Science.gov (United States)

    Endo, Hideki; Niizawa, Nobuharu; Komiya, Teruyuki; Kawada, Shinichiro; Kimura, Junpei; Itou, Takuya; Koie, Hiroshi; Sakai, Takeo

    2007-10-01

    The gross anatomy of the mastication system of the giant anteater (Myrmecophaga tridactyla) was examined by means of three-dimensional image analysis. The anteater rotates the mandibles medially and laterally to control its tongue when it is elongated and to house it when it is relaxed. Three-dimensional CT image analysis demonstrated that the shape and size of the oral cavity changes drastically when the mandibles are rotated. The oral cavity expands bilaterally when the dorsal part of the mandibles bend medially. Macroscopic observations and muscle-weight data supported the observation that the superficial temporal and medial pterygoid muscles act as the main medial and lateral rotators of the mandible, respectively. The low height of the mandibular ramus and the incomplete zygomatic arch in this species represent adaptations for the rotational movement of the mandibles, since they both contribute to the medially oriented transmission of force from the temporal muscles and to preventing collision between the mandibles and the cranium during the rotational movement.

  17. 16 multi-slice CT three-dimensional and multiplanar reconstruction for evaluation of pediatric congenital scoliosis

    International Nuclear Information System (INIS)

    Peng Yun; Zhang Ningning; Zhang Xuejun; Sun Guoqiang; Zeng Jinjin

    2006-01-01

    Objective: Our study is to use of 16 MSCT three-dimensional images and multiplanar reconstruction images in the preoperative investigation of patients with congenital scoliosis, to study its technical advantage and work out surgical plan. Methods: Twenty-seven pediatric patients with congenital scoliosis processing between April to October 2004 were reviewed, including 13 boys and 14 girls. X-ray plain film and sixteen multi-slice CT examination on curved/standard multiplanar reconstruction and three- dimensional computed tomographic imaging may offer, many potential advantages for defining congenital spine anomalies liable to cause progression of scoliosis, including visualization of the deformity in any plane, from any angle, with the overlying structures subtracted. Results: Ten patients had segmentation defects, 6 patients underwent formation defects, 11 patients had complex, unclassifiable anomalies. The patients of rib deformity were found in 15 patients, the most prominent part of the rib cage deformity was at the same level as the most rotated vertebra in 7 patients; 8 patients had vertebral anomalies accompanied with diastematomyelie, including 6 patients with uncompleted or completed bony spur. In 19 of 27 cases, the muhiplanar reconstruction and three-dimensional images allowed identification of unrecognized malformations and completely evaluated the degree of scoliosis, during conventional X-ray images and axial CT images, including volume 3D imaging evaluated approximately classification and modality of complex anomalies in 11 cases, which were unclassifiable malformation in 7 cases and unsegmented bar with contralateral hemivertebrae; 4 children had segmentation defects revealed unilateral unsegmented bar (3 cases) and bilateral block vertebra (1 case) in volume 3D reconstruction images; 2 children were found occultation hemivertebrae which were not been discovered during conventional X-ray images and axial CT images; and 2 children were revaluated

  18. Three-dimensional quantitative CT of the proximal femur: Relationship to vertebral trabecular bone density

    International Nuclear Information System (INIS)

    Bhasin, S.; Zlatkin, M.B.; Sartoris, D.J.; Andre, M.; Resnick, D.

    1987-01-01

    Integrated cancellous, cortical, and total bone density in the femoral neck and inter-trochanteric region was measured bilaterally in 25 women aged 35-90 years (mean age, 65). Contiguous-section (1-cm-thick) data were analyzed using three-dimensional histogram software on a Cemax 1000 image processor. Single-section quantitative CT was used to determine mean mineral equivalent values for vertebral cancellous bone from T-11 to L-3 in each woman. Significant correlation was found between cancellous bone density at the two sites. Cortical and total bone densities in the proximal femur were predicted less well with vertebral cancellous data, suggesting a greater dependence on weight-bearing and activity factors

  19. Three dimensional reconstruction of fossils with X-ray CT and computer graphics

    Energy Technology Data Exchange (ETDEWEB)

    Hamada, Takashi; Tateno, Satoko (Tokyo Univ. (Japan). Coll. of Arts and Sciences); Suzuki, Naoki

    1991-12-01

    We have developed a method for three dimensional (3D) visualization of fossils such as trilobites and ammonites by non-destructive measurement and computer graphics. The imaging techniques in the medical sciences are applied for fossils by us to have quantitative data analyses on the structural and functional features of some extinct creatures. These methods are composed of a high resolutional X-ray computed tomography (X-ray CT) and computer graphics. We are able to observe not only outer shape but also inner structure of fossils as a 3D image by this method. Consequently, the shape and volume are measurable on these 3D image quantitatively. In addition to that, it is able to reconstruct an ideal figure from the deformed fossils by graphical treatments of the data. Such a 3D reconstruction method is useful to obtain a new information from the paleontological standpoint. (author).

  20. Three dimensional reconstruction of fossils with X-ray CT and computer graphics

    International Nuclear Information System (INIS)

    Hamada, Takashi; Tateno, Satoko; Suzuki, Naoki.

    1991-01-01

    We have developed a method for three dimensional (3D) visualization of fossils such as trilobites and ammonites by non-destructive measurement and computer graphics. The imaging techniques in the medical sciences are applied for fossils by us to have quantitative data analyses on the structural and functional features of some extinct creatures. These methods are composed of a high resolutional X-ray computed tomography (X-ray CT) and computer graphics. We are able to observe not only outer shape but also inner structure of fossils as a 3D image by this method. Consequently, the shape and volume are measurable on these 3D image quantitatively. In addition to that, it is able to reconstruct an ideal figure from the deformed fossils by graphical treatments of the data. Such a 3D reconstruction method is useful to obtain a new information from the paleontological standpoint. (author)

  1. Lung nodule detection performance in five observers on computed tomography (CT) with adaptive iterative dose reduction using three-dimensional processing (AIDR 3D) in a Japanese multicenter study: Comparison between ultra-low-dose CT and low-dose CT by receiver-operating characteristic analysis.

    Science.gov (United States)

    Nagatani, Yukihiro; Takahashi, Masashi; Murata, Kiyoshi; Ikeda, Mitsuru; Yamashiro, Tsuneo; Miyara, Tetsuhiro; Koyama, Hisanobu; Koyama, Mitsuhiro; Sato, Yukihisa; Moriya, Hiroshi; Noma, Satoshi; Tomiyama, Noriyuki; Ohno, Yoshiharu; Murayama, Sadayuki

    2015-07-01

    To compare lung nodule detection performance (LNDP) in computed tomography (CT) with adaptive iterative dose reduction using three dimensional processing (AIDR3D) between ultra-low dose CT (ULDCT) and low dose CT (LDCT). This was part of the Area-detector Computed Tomography for the Investigation of Thoracic Diseases (ACTIve) Study, a multicenter research project being conducted in Japan. Institutional Review Board approved this study and informed consent was obtained. Eighty-three subjects (body mass index, 23.3 ± 3.2) underwent chest CT at 6 institutions using identical scanners and protocols. In a single visit, each subject was scanned using different tube currents: 240, 120 and 20 mA (3.52, 1.74 and 0.29 mSv, respectively). Axial CT images with 2-mm thickness/increment were reconstructed using AIDR3D. Standard of reference (SOR) was determined based on CT images at 240 mA by consensus reading of 2 board-certificated radiologists as to the presence of lung nodules with the longest diameter (LD) of more than 3mm. Another 5 radiologists independently assessed and recorded presence/absence of lung nodules and their locations by continuously-distributed rating in CT images at 20 mA (ULDCT) and 120 mA (LDCT). Receiver-operating characteristic (ROC) analysis was used to evaluate LNDP of both methods in total and also in subgroups classified by LD (>4, 6 and 8 mm) and nodular characteristics (solid and ground glass nodules). For SOR, 161 solid and 60 ground glass nodules were identified. No significant difference in LNDP for entire solid nodules was demonstrated between both methods, as area under ROC curve (AUC) was 0.844 ± 0.017 in ULDCT and 0.876 ± 0.026 in LDCT (p=0.057). For ground glass nodules with LD 8mm or more, LNDP was similar between both methods, as AUC 0.899 ± 0.038 in ULDCT and 0.941 ± 0.030 in LDCT. (p=0.144). ULDCT using AIDR3D with an equivalent radiation dose to chest x-ray could have comparable LNDP to LDCT with AIDR3D except for smaller ground

  2. Three dimensional volume rendering virtual endoscopy of the ossicles using a multi-row detector CT: applications and limitations

    International Nuclear Information System (INIS)

    Kim, Su Yeon; Choi, Sun Seob; Kang, Myung Jin; Shin, Tae Beom; Lee, Ki Nam; Kang, Myung Koo

    2005-01-01

    This study was conducted to know the applications and limitations of three dimensional volume rendering virtual endoscopy of the ossicles using a multi-row detector CT. This study examined 25 patients who underwent temporal bone CT using a 16-row detector CT as a result of hearing problems or trauma. The axial CT scan of the temporal bone was performed with a 0.6 mm collimation, and a reconstruction was carried out with a U70u sharp of kernel value, a 1 mm thickness and 0.5-1.0 mm increments. After observing the ossicles in the axial and coronal images, virtual endoscopy was performed using a three dimensional volume rendering technique with a threshold value of-500 HU. The intra-operative otoendoscopy was performed in 12 ears, and was compared with the virtual endoscopy findings. Virtual endoscopy of the 29 ears without hearing problems demonstrated hypoplastic or an incomplete depiction of the stapes superstructures in 25 ears and a normal depiction in 4 ears. Virtual endoscopy of 21 ears with hearing problems demonstrated no ossicles in 1 ears, no malleus in 3 ears, a malleoincudal subluxation in 6 ears, a dysplastic incus in 5 ears, an incudostapedial subluxation in 9 ears, dysplastic stapes in 2 ears, a hypoplastic or incomplete depiction of the stapes in 16 ears and no stapes in 1 ears. In contrast to the intra-operative otoendoscopy, 8 out of 12 ears showed a hypoplastic or deformed stapes in the virtual endoscopy. Volume rendering virtual endoscopy using a multi-row detector CT is an excellent method for evaluation the ossicles in three dimension, even thought the partial volume effect for the stapes superstructures needs to be considered

  3. Three-dimensional anatomical evaluation of bronchial artery with CT angiography

    International Nuclear Information System (INIS)

    Yu Hong; Li Huimin; Xiao Xiangsheng; Liu Shiyuan; Li Chengzhou; Tao Xiaofeng

    2006-01-01

    Objective: To evaluate the ability of CT angiography in identifying and demonstrating the origins and courses of bronchial arteries by using the three-dimensional reformation technique. Methods Four hundred and forty-three eases were examined with thin-section enhanced MSCT. Three-dimensional images of bronchial arteries were processed at the workstation. Spatial anatomical characters of the bronchial arteries using volume rendering(VR), muhiplanar reconstruction (MPR), and maxium intensity projection (MIP) were observed. Results: At least one bronchial artery was clearly displayed in VR in 359 eases. The right bronchial arteries mainly appeared to originate from the right intercostal artery (213/436, 48.85% ) and descending aorta (207/436, 47.48%), while the left bronchial arteries mainly from the descending aorta (363/371, 97.84%). The right bronchial arteries of the descending aorta were mainly arised from fight wall (95/207, 45.89%), and then the anterior wall (88/207, 42.51%), while the left bronchial arteries of the descending aorta mainly arised from anterior wall of the aorta (272/363, 74.93%). The common trunk originated from the descending aorta mainly positioned in the anterior wall (57/77, 74.03%). 49.31% (215/436) of the fight bronchial arteries were coursing across the posterior edge of the right main bronchi, 35.55% (155/436) coursing the inferior edge, while 60.11% (223/371) of left bronchial arteries coursing forward across the superior edger of the left main bronchi, the others coursing the inferior or the posterior edge. There were eleven bronchial artery distribution patterns, with the right and left ones predominating (192/359, 53.48%), and then two right and one left (63/359, 17.55%). Conclusion: The bronchial artery anatomy was complicated, and CT angiography could clearly visualize the features. (authors)

  4. Clinical application of the three-dimensional reconstruction of spiral CT pneumocolon

    International Nuclear Information System (INIS)

    Yu Shenping; Li Ziping; Xu Dasheng; Lin Erjian; Lin Peizhang; Xu Qiaolan

    2000-01-01

    Objective: To evaluate the clinical role of the 3 types of reconstruction of the spiral CT pneumocolon in the diagnosis of colon lesions. Methods: Three types of reconstruction with spiral CT pneumocolon including air cast imaging (ACI), CT virtual endoscopy (CTVE), and multiple planner reconstruction (MPR) in 34 patients with colorectal cancer or polyps were correlated with surgical pathology respectively. Results: Among the 34 patients, 30 was colorectal cancer and 6 was polyps (2 of which in the proximal lumen of 2 colon cancer). (1) Comparison between the 3 types of the spiral CT pneumocolon reconstruction and pathology in colorectal cancer. 1) ACI: tumor patterns: coincide (n =22), anti-coincide (n = 8); tumor extension: coincide (n = 24), anti-coincide (n = 6); tumor size: coincide (n = 28), anti-coincide (n = 2). 2) CTVE: tumor patterns: coincide (n = 26), anti-coincide (n = 4); tumor extension: coincide (n = 25), anti-coincide ( n 5); tumor size: coincide (n = 23), anti-coincide (n = 7). 3) MPR: tumor patterns: coincide (n = 24), anti-coincide (n = 6); tumor extension: coincide (n = 30), anti-coincide (n = 0); tumor size: coincide (n = 26), anti-coincide (n = 4). (2) Comparison between the 3 types of the spiral CT pneumocolon reconstruction and pathology in colorectal polyps: the lesions were displayed in 4 (ACI) and in 6 (CTVE and MPR). Conclusion: (1) For the diagnosis of colorectal cancers: CTVE was the best means to display the tumor patterns, MPR most correct to judge the tumor extension, and ACI most suitable to measure the tumor size. (2) For the diagnosis of colorectal polyps, ACI can be used for oriented diagnosis, CTVE can well display the intra-luminal three-dimensional structure and can be used for characteristic diagnosis, MPR can be used for differential diagnosis

  5. Clinical applications for multiplanar- and three-dimensional-reconstructions by helical-CT for the diagnosis of acetabular fractures

    International Nuclear Information System (INIS)

    Stroszczynski, C.; Schedel, H.; Stoeckle, U.; Wellmann, A.; Beier, J.; Wicht, L.; Hoffmann, R.; Felix, R.

    1996-01-01

    This review describes recent visualizations of computed tomography for the diagnosis of acetabular fractures. The techniques of conventional and helical-CT for the imaging of the acetabulum are compared. Furthermore, the different methods of multiplaner and three-dimensional reconstructions e.g. shaded surface display, maximum intensity projection, and volume rendering are presented. Figures of multiplanar and three-dimensional imaging for fractures of the pelvis is discussed. (orig.) [de

  6. Three-dimensional motion analysis of an improved head immobilization system for simulation, CT, MRI, and PET imaging

    International Nuclear Information System (INIS)

    Thornton, A.F. Jr.; Ten Haken, R.K.; Gerhardsson, A.; Correll, M.

    1991-01-01

    A mask/marker immobilization system for the routine radiation therapy treatment of head and neck disease is described, utilizing a commercially available thermoplastic mesh, indexed and mounted for a rigid frame attached to the therapy couch. Designed to permit CT, MRI, and PET diagnostics scans of the patient to be performed in the simulation and treatment position employing the same mask, the system has been tested in order to demonstrate the reproducibility of immobilization throughout a radical course of irradiation. Three-dimensional analysis of patient position over an 8-week course of daily radiation treatment has been performed for 9 patients from digitization of anatomic points identified on orthogonal radiographs. Studies employing weekly constructed system permits rapid mask formation to be performed on the treatment simulator, resulting in an immobilization device comparable to masks produced with vacuum-forming techniques. Details of motion analysis and central axis CT, MRI, and PET markers are offered. (author). 16 refs.; 3 figs

  7. Sexual difference of human hyoid bones. Quantitative analysis of CT three-dimensional image

    International Nuclear Information System (INIS)

    Terashima, Yoshiharu; Izumi, Masahiro; Hanamura, Hajime; Takada, Yasushi

    2007-01-01

    We investigated sexual differences in hyoid bones of 50 dissected Japanese cadavers: 26 males (aged 52 to 101, averaged 81.9 years) and 24 females (aged 61 to 94, averaged 83.6 years). All extracted hyoid bones were scanned by multi-slice CT. Length of body, distance between bilateral greater horns, length of greater horns, distance between bilateral lesser horns, and length of lesser horns were measured on CT three-dimensional image, and were analyzed by univariate and multivariate statistics. t-tests showed significant sexual differences in all the dimensions; being about 20% longer in males than in females. In principal component analysis using five hyoid dimensions, factor 1, expressing the overall size of the bone, fairly separated each sex, but factors 2 and 3, expressing the shape, did not. Discriminant analysis by a stepwise model, using all the eight dimensions, classified sex rightly (88.6% of the bone) by a function of two dimensions: length of body and distance between bilateral tips of lesser horns. In conclusion, a sexual difference of the hyoid bone was evident in size rather than in shape. (author)

  8. Do Three-dimensional Visualization and Three-dimensional Printing Improve Hepatic Segment Anatomy Teaching? A Randomized Controlled Study.

    Science.gov (United States)

    Kong, Xiangxue; Nie, Lanying; Zhang, Huijian; Wang, Zhanglin; Ye, Qiang; Tang, Lei; Li, Jianyi; Huang, Wenhua

    2016-01-01

    Hepatic segment anatomy is difficult for medical students to learn. Three-dimensional visualization (3DV) is a useful tool in anatomy teaching, but current models do not capture haptic qualities. However, three-dimensional printing (3DP) can produce highly accurate complex physical models. Therefore, in this study we aimed to develop a novel 3DP hepatic segment model and compare the teaching effectiveness of a 3DV model, a 3DP model, and a traditional anatomical atlas. A healthy candidate (female, 50-years old) was recruited and scanned with computed tomography. After three-dimensional (3D) reconstruction, the computed 3D images of the hepatic structures were obtained. The parenchyma model was divided into 8 hepatic segments to produce the 3DV hepatic segment model. The computed 3DP model was designed by removing the surrounding parenchyma and leaving the segmental partitions. Then, 6 experts evaluated the 3DV and 3DP models using a 5-point Likert scale. A randomized controlled trial was conducted to evaluate the educational effectiveness of these models compared with that of the traditional anatomical atlas. The 3DP model successfully displayed the hepatic segment structures with partitions. All experts agreed or strongly agreed that the 3D models provided good realism for anatomical instruction, with no significant differences between the 3DV and 3DP models in each index (p > 0.05). Additionally, the teaching effects show that the 3DV and 3DP models were significantly better than traditional anatomical atlas in the first and second examinations (p < 0.05). Between the first and second examinations, only the traditional method group had significant declines (p < 0.05). A novel 3DP hepatic segment model was successfully developed. Both the 3DV and 3DP models could improve anatomy teaching significantly. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  9. Application of three-dimensional CT reconstruction technology on inferior oblique muscle in congenital superior oblique palsy

    Directory of Open Access Journals (Sweden)

    Yang Zhang

    2014-05-01

    Full Text Available AIM: To investigate the viability of the morphology of inferior oblique muscle observed stereoscopically using 3-dimensional CT reconstruction technique. METHODS: This control study included of 29 cases which were clinically diagnosed with monocular congenital superior oblique palsy, examined by dimensional CT. The images of the inferior oblique muscle were reconstructed by Mimics software. 3D digital images on the basis of CT scanning data of the individuals were established. Observing the morphology of binocular inferior oblique muscle by self-controlled design, we compared the maximum transverse diameter of inferior oblique muscle of paralyzed eye with non-paralyzed one. We chose 5% as the significant level.RESULTS: The reconstructed results of 3-dimensional CT scan showed that not all of the inferior oblique abdominal muscle of paralyzed eyes were thinner than that of the non-paralyzed eye in maximum transverse diameter of cross-sectional area. The maximum transverse diameter of inferior oblique muscle was measured. The average maximum transverse diameter of the paralyzed eye was 6.797±1.083mm and the non-paralyzed eye was 6.507±0.848mm. The maximum transverse diameter of inferior oblique muscle of paralyzed eye did not, however, differ significantly from the normal(P>0.05. CONCLUSION: The three-dimensional CT reconstruction technology can be used for preoperative evaluation of the morphology of inferior oblique muscle.

  10. Three-dimensional studies on resorption spaces and developing osteons.

    Science.gov (United States)

    Tappen, N C

    1977-07-01

    Resorption spaces and their continuations as developing osteons were traced in serial cross sections from decalcified long bones of dogs, baboons and a man, and from a human rib. Processes of formation of osteons and transverse (Volkmann's) canals can be inferred from three-dimensional studies. Deposits of new osseous tissue begin to line the walls of the spaces soon after termination of resorption. The first deposits are osteoid, usually stained very darkly by the silver nitrate procedure utilized, but a lighter osteoid zone adjacent to the canals occurs frequently. Osteoid linings continue to be produced as lamellar bone forms around them; the large canals of immature osteons usually narrow very gradually. Frequently they terminate both proximally and distally as resorption spaces, indicating that osteons often advance in opposite directions as they develop. Osteoclasts of resorption spaces tunnel preferentially into highly mineralized bone, and usually do not use previously existing canals as templates for their advance. Osteons evidently originate by localized resorption of one side of the wall of an existing vascular channel in bone, with subsequent orientation of the resorption front along the axis of the shaft. Advancing resorption spaces also apparently stimulate the formation of numerous additional transverse canal connections to neighboring longitudinal canals. Serial tracing and silver nitrate differential staining combine to reveal many of the processes of bone remodeling at work, and facilitate quantitative treatment of the data. Further uses in studies of bone tissue and associated cells are recommended.

  11. Study of spatial resolution in three-dimensional rotational angiography

    International Nuclear Information System (INIS)

    Enoki, Takuya; Nasada, Toshiya; Matsumoto, Kazuma; Umehara, Takayoshi

    2006-01-01

    In interventional radiology (IVR) of cerebral aneurysms, it is important to understand the form and physical relationships between the cerebral aneurysm and the surrounding vessels. However, because the vessels in the head area are highly complex, it can be difficult to comprehend the structure using conventional angiography. Therefore, three-dimensional rotational angiography (3D-RA) has been used in recent years. This article discusses studies of the spatial resolution of 3D-RA. We reconstructed 3D-RA of an acrylic slit phantom (slit widths: 0.5, 0.75, 1.0, 1.5 mm) and examined spatial resolution by visual evaluation and profile curves. When the slit phantom was arranged to avoid the effect of beam hardening, the spatial resolution of 3D-RA was found to be as high as 0.75 mm. When the slit phantom was placed orthogonal to the rotational axis of the C-arm, the spatial resolution of 3D-RA was decreased because of the cone angle effect of X-rays. However, it was considered within the allowable range for clinical study. Consequently, 3D-RA is valuable in IVR. (author)

  12. Study of Three-Dimensional Image Brightness Loss in Stereoscopy

    Directory of Open Access Journals (Sweden)

    Hsing-Cheng Yu

    2015-10-01

    Full Text Available When viewing three-dimensional (3D images, whether in cinemas or on stereoscopic televisions, viewers experience the same problem of image brightness loss. This study aims to investigate image brightness loss in 3D displays, with the primary aim being to quantify the image brightness degradation in the 3D mode. A further aim is to determine the image brightness relationship to the corresponding two-dimensional (2D images in order to adjust the 3D-image brightness values. In addition, the photographic principle is used in this study to measure metering values by capturing 2D and 3D images on television screens. By analyzing these images with statistical product and service solutions (SPSS software, the image brightness values can be estimated using the statistical regression model, which can also indicate the impact of various environmental factors or hardware on the image brightness. In analysis of the experimental results, comparison of the image brightness between 2D and 3D images indicates 60.8% degradation in the 3D image brightness amplitude. The experimental values, from 52.4% to 69.2%, are within the 95% confidence interval

  13. Micromagnetic studies of three-dimensional pyramidal shell structures

    International Nuclear Information System (INIS)

    Knittel, A; Franchin, M; Fischbacher, T; Fangohr, H; Nasirpouri, F; Bending, S J

    2010-01-01

    We present a systematic numerical analysis of the magnetic properties of pyramidal-shaped core-shell structures in a size range below 400 nm. These are three-dimensional structures consisting of a ferromagnetic shell which is grown on top of a non-magnetic core. The standard micromagnetic model without the magnetocrystalline anisotropy term is used to describe the properties of the shell. We vary the thickness of the shell between the limiting cases of an ultra-thin shell and a conventional pyramid and delineate different stable magnetic configurations. We find different kinds of single-domain states, which predominantly occur at smaller system sizes. In analogy to equivalent states in thin square films we term these onion, flower, C and S states. At larger system sizes, we also observe two types of vortex states, which we refer to as symmetric and asymmetric vortex states. For a classification of the observed states, we derive a phase diagram that specifies the magnetic ground state as a function of structure size and shell thickness. The transitions between different ground states can be understood qualitatively. We address the issue of metastability by investigating the stability of all occurring configurations for different shell thicknesses. For selected geometries and directions hysteresis measurements are analysed and discussed. We observe that the magnetic behaviour changes distinctively in the limit of ultra-thin shells. The study has been motivated by the recent progress made in the growth of faceted core-shell structures.

  14. MR study of intracranial disease with three-dimensional FLASH

    International Nuclear Information System (INIS)

    Runge, V.M.; Wood, M.L.; Kaufman, D.M.; Nelson, K.L.; Traill, M.R.; Wolpert, S.M.

    1987-01-01

    A three-dimensional FLASH technique was used to study 36 patients with intracranial disease at 1 T (Siemens Magnetom). This included 15 cases of intracranial neoplastic disease, four with the application of intravenous Gd-DTPA. Contiguous thin sections (1-2 mm thick) were acquired of the entire intracranial contents using one acquisition (scan time of 5-15 minutes). A MIPRON (KONTRON Instruments) image processing work station was used for rapid image display and 3D reconstruction. 3D FLASH was found to be superior to spin-echo imaging at 1 T for the detection of hemorrhage. 3D acquisition also provided superior localization of neoplastic disease. The T1 contrast achieved was comparable to spin-echo technique with a repetition time/echo time of .6/17. The advantages in terms of lesion localization and thin-section imaging with high spatial resolution of the entire brain may lead to use of 3D FLASH in place of conventional spin-echo imaging

  15. A proposal of a three-dimensional CT measurement method of maxillofacial structure

    International Nuclear Information System (INIS)

    Tanaka, Ray; Hayashi, Takafumi

    2007-01-01

    Three-dimensional CT measurement is put in practice in order to grasp the pathological condition on diseases such as the temporomandibular joint disorder, maxillofacial anomaly, jaw deformity, or fracture which cause the morphologic changes of the maxillofacial bones. On the 3D measurement, the unique system that is obtained by volume rendering 3D images with a simultaneous reference of axial images combined with coronal and sagittal multi-planar reconstruction (MPR) images (we call this MPR referential method), is employed in order to define the measurement points. Our purpose in this report is to indicate the usefulness of this unique method by comparing with the common way to define the measurement points on only 3D reconstruction images without consulting of MPR images. Clinical CT data obtained from a male patient with skeletal malocclusion was used. Contiguous axial images were reconstructed at 4 times magnification, with a reconstruction interval of 0.5 mm, focused on the temporomandibular joint region in his left side. After these images were converted to Digital Imaging and Communications in Medicine (DICOM) format and sent to personal computer (PC), 3D reconstruction image was created using free 3D DICOM medical image viewer. The coordinates of 3 measurement points (the lateral and medial pole of the mandibular condyle, and the left foramen ovale) were defined with MPR images (MPR coordinates) as reference coordinates, and then the coordinates that were defined on only 3D reconstruction image without consulting to MPR images (3D coordinates) were compared to those of MPR coordinates. Three examiners were engaged independently 10 times for every measurement point. In our result, there was no correspondence between 3D coordinates and MPR coordinates, and contribution of 3D coordinates showed a variety in every measurement point and in every observer. We deemed that ''MPR referential method'' is useful to assess the location of the target point of anatomical

  16. How many CT detector rows are necessary to perform adequate three dimensional visualization?

    International Nuclear Information System (INIS)

    Fischer, Lars; Tetzlaff, Ralf; Schoebinger, Max; Radeleff, Boris; Bruckner, Thomas; Meinzer, H.P.; Buechler, M.W.; Schemmer, Peter

    2010-01-01

    Introduction: The technical development of computer tomography (CT) imaging has experienced great progress. As consequence, CT data to be used for 3D visualization is not only based on 4 row CTs and 16 row CTs but also on 64 row CTs, respectively. The main goal of this study was to examine whether the increased amount of CT detector rows is correlated with improved quality of the 3D images. Material and Methods: All CTs were acquired during routinely performed preoperative evaluation. Overall, there were 12 data sets based on 4 detector row CT, 12 data sets based on 16 detector row CT, and 10 data sets based on 64 detector row CT. Imaging data sets were transferred to the DKFZ Heidelberg using the CHILI teleradiology system. For the analysis all CT scans were examined in a blinded fashion, i.e. both the name of the patient as well as the name of the CT brand were erased. For analysis, the time for segmentation of liver, both portal and hepatic veins as well as the branching depth of portal veins and hepatic veins was recorded automatically. In addition, all results were validated in a blinded fashion based on given quality index. Results: Segmentation of the liver was performed in significantly shorter time (p < 0.01, Kruskal-Wallis test) in the 16 row CT (median 479 s) compared to 4 row CT (median 611 s), and 64 row CT (median 670 s), respectively. The branching depth of the portal vein did not differ significantly among the 3 different data sets (p = 0.37, Kruskal-Wallis test). However, the branching depth of the hepatic veins was significantly better (p = 0.028, Kruskal-Wallis test) in the 4 row CT and 16 row CT compared to 64 row CT. The grading of the quality index was not statistically different for portal veins and hepatic veins (p = 0.80, Kruskal-Wallis test). Even though the total quality index was better for the vessel tree based on 64 row CT data sets (mean scale 2.6) compared to 4 CT row data (mean scale 3.25) and 16 row CT data (mean scale 3.0), these

  17. Clinical Application of colored three-dimensional CT (3D-CT) for brain tumors using helical scanning CT (HES-CT)

    International Nuclear Information System (INIS)

    Ogura, Yuko; Katada, Kazuhiro; Fujisawa, Kazuhisa; Imai, Fumihiro; Kawase, Tsukasa; Kamei, Yoshifumi; Kanno, Tetsuo; Takeshita, Gen; Koga, Sukehiko

    1995-01-01

    We applied colored three-dimensional CT (colored 3D-CT) images to distinguish brain tumors from the surrounding vascular and bony structures using a work station system and helical scanning CT (HES-CT). CT scanners with a slip-ring system were employed (TCT-900S and X vigor). A slice thickness of 2 mm and bed speed of 2 mm/s were used. The volume of contrast medium injected was 60 to 70 ml. Four to 8 colors were used for the tissue segmentation on the workstation system (xtension) using the data transferred from HES-CT. Tissue segmentation succeeded on the colored 3D-CT images in all 13 cases. The relationship between the tumors and the surrounding structures were easily recognized. The technique was useful to simulate operative fields, because deep structures could be visualized by cutting and drilling the colored 3D-CT volumetric data. On the basis of our findings, we suggest that colored 3D-CT images should be used as a supplementary aid for preoperative simulation. (author)

  18. Three-dimensional focus of attention for iterative cone-beam micro-CT reconstruction

    International Nuclear Information System (INIS)

    Benson, T M; Gregor, J

    2006-01-01

    Three-dimensional iterative reconstruction of high-resolution, circular orbit cone-beam x-ray CT data is often considered impractical due to the demand for vast amounts of computer cycles and associated memory. In this paper, we show that the computational burden can be reduced by limiting the reconstruction to a small, well-defined portion of the image volume. We first discuss using the support region defined by the set of voxels covered by all of the projection views. We then present a data-driven preprocessing technique called focus of attention that heuristically separates both image and projection data into object and background before reconstruction, thereby further reducing the reconstruction region of interest. We present experimental results for both methods based on mouse data and a parallelized implementation of the SIRT algorithm. The computational savings associated with the support region are substantial. However, the results for focus of attention are even more impressive in that only about one quarter of the computer cycles and memory are needed compared with reconstruction of the entire image volume. The image quality is not compromised by either method

  19. MR vs CT imaging: low rectal cancer tumour delineation for three-dimensional conformal radiotherapy.

    LENUS (Irish Health Repository)

    O'Neill, B D P

    2009-06-01

    Modern three-dimentional radiotherapy is based upon CT. For rectal cancer, this relies upon target definition on CT, which is not the optimal imaging modality. The major limitation of CT is its low inherent contrast resolution. Targets defined by MRI could facilitate smaller, more accurate, tumour volumes than CT. Our study reviewed imaging and planning data for 10 patients with locally advanced low rectal cancer (defined as < 6 cm from the anal verge on digital examination). Tumour volume and location were compared for sagittal pre-treatment MRI and planning CT. CT consistently overestimated all tumour radiological parameters. Estimates of tumour volume, tumour length and height of proximal tumour from the anal verge were larger on planning CT than on MRI (p < 0.05). Tumour volumes defined on MRI are smaller, shorter and more distal from the anal sphincter than CT-based volumes. For radiotherapy planning, this may result in smaller treatment volumes, which could lead to a reduction in dose to organs at risk and facilitate dose escalation.

  20. Comparative Three-Dimensional Morphology of Baleen: Cross-Sectional Profiles and Volume Measurements Using CT Images.

    Science.gov (United States)

    Jensen, Megan M; Saladrigas, Amalia H; Goldbogen, Jeremy A

    2017-11-01

    Baleen whales are obligate filter feeders, straining prey-laden seawater through racks of keratinized baleen plates. Despite the importance of baleen to the ecology and natural history of these animals, relatively little work has been done on baleen morphology, particularly with regard to the three-dimensional morphology and structure of baleen. We used computed tomography (CT) scanning to take 3D images of six baleen specimens representing five species, including three complete racks. With these images, we described the three-dimensional shape of the baleen plates using cross-sectional profiles from within the gum tissue to the tip of the plates. We also measured the percentage of each specimen that was composed of either keratinized plate material or was void space between baleen plates, and thus available for seawater flow. Baleen plates have a complex three-dimensional structure with curvature that varies across the anterior-posterior, proximal-distal, and medial-lateral (lingual-labial) axes. These curvatures also vary with location along the baleen rack, and between species. Cross-sectional profiles resemble backwards-facing airfoils, and some specimens display S-shaped, or reflexed, camber. Within a baleen specimen, the intra-baleen void volume correlates with the average bristle diameter for a species, suggesting that essentially, thinner plates (with more space between them for flow) have thinner bristles. Both plate curvature and the relative proportions of plate and void volumes are likely to have implications for the mechanics of mysticete filtration, and future studies are needed to determine the particular functions of these morphological characters. Anat Rec, 300:1942-1952, 2017. © 2017 The Authors The Anatomical Record published by Wiley Periodicals, Inc. on behalf of American Association of Anatomists. © 2017 The Authors The Anatomical Record published by Wiley Periodicals, Inc. on behalf of American Association of Anatomists.

  1. Lung nodule detection performance in five observers on computed tomography (CT) with adaptive iterative dose reduction using three-dimensional processing (AIDR 3D) in a Japanese multicenter study: Comparison between ultra-low-dose CT and low-dose CT by receiver-operating characteristic analysis

    Energy Technology Data Exchange (ETDEWEB)

    Nagatani, Yukihiro, E-mail: yatsushi@belle.shiga-med.ac.jp [Department of Radiology, Shiga University of Medical Science, Otsu 520-2192, Shiga (Japan); Takahashi, Masashi; Murata, Kiyoshi [Department of Radiology, Shiga University of Medical Science, Otsu 520-2192, Shiga (Japan); Ikeda, Mitsuru [Department of Radiological and Medical Laboratory Science, Nagoya University Graduate School of Medicine, Nagoya 461-8673, Aichi (Japan); Yamashiro, Tsuneo [Department of Radiology, Graduate School of Medical Science, University of the Ryukyus, Nishihara 903-0215, Okinawa (Japan); Miyara, Tetsuhiro [Department of Radiology, Graduate School of Medical Science, University of the Ryukyus, Nishihara 903-0215, Okinawa (Japan); Department of Radiology, Okinawa Prefectural Yaeyama Hospital, Ishigaki 907-0022, Okinawa (Japan); Koyama, Hisanobu [Department of Radiology, Kobe University Graduate School of Medicine, Kobe 650-0017, Hyogo (Japan); Koyama, Mitsuhiro [Department of Radiology, Osaka Medical College, Takatsuki 569-8686, Osaka (Japan); Sato, Yukihisa [Department of Radiology, Osaka University Graduate School of Medicine, Suita 565-0871, Osaka (Japan); Department of Radiology, Osaka Medical Center of Cancer and Cardiovascular Diseases, Osaka 537-8511, Osaka (Japan); Moriya, Hiroshi [Department of Radiology, Ohara General Hospital, Fukushima 960-8611 (Japan); Noma, Satoshi [Department of Radiology, Tenri Hospital, Tenri 632-8552, Nara (Japan); Tomiyama, Noriyuki [Department of Radiology, Osaka University Graduate School of Medicine, Suita 565-0871, Osaka (Japan); Ohno, Yoshiharu [Department of Radiology, Kobe University Graduate School of Medicine, Kobe 650-0017, Hyogo (Japan); Murayama, Sadayuki [Department of Radiology, Graduate School of Medical Science, University of the Ryukyus, Nishihara 903-0215, Okinawa (Japan)

    2015-07-15

    Highlights: • Using AIDR 3D, ULDCT showed comparable LND of solid nodules to LDCT. • Using AIDR 3D, LND of smaller GGN in ULDCT was inferior to that in LDCT. • Effective dose in ULDCT was about only twice of that in chest X-ray. • BMI values in study population were mostly in the normal range body habitus. - Abstract: Purpose: To compare lung nodule detection performance (LNDP) in computed tomography (CT) with adaptive iterative dose reduction using three dimensional processing (AIDR3D) between ultra-low dose CT (ULDCT) and low dose CT (LDCT). Materials and methods: This was part of the Area-detector Computed Tomography for the Investigation of Thoracic Diseases (ACTIve) Study, a multicenter research project being conducted in Japan. Institutional Review Board approved this study and informed consent was obtained. Eighty-three subjects (body mass index, 23.3 ± 3.2) underwent chest CT at 6 institutions using identical scanners and protocols. In a single visit, each subject was scanned using different tube currents: 240, 120 and 20 mA (3.52, 1.74 and 0.29 mSv, respectively). Axial CT images with 2-mm thickness/increment were reconstructed using AIDR3D. Standard of reference (SOR) was determined based on CT images at 240 mA by consensus reading of 2 board-certificated radiologists as to the presence of lung nodules with the longest diameter (LD) of more than 3 mm. Another 5 radiologists independently assessed and recorded presence/absence of lung nodules and their locations by continuously-distributed rating in CT images at 20 mA (ULDCT) and 120 mA (LDCT). Receiver-operating characteristic (ROC) analysis was used to evaluate LNDP of both methods in total and also in subgroups classified by LD (>4, 6 and 8 mm) and nodular characteristics (solid and ground glass nodules). Results: For SOR, 161 solid and 60 ground glass nodules were identified. No significant difference in LNDP for entire solid nodules was demonstrated between both methods, as area under ROC

  2. A study on reproducibility of three-dimensional measurement for an evaluation of craniofacial morphology

    International Nuclear Information System (INIS)

    Nagai, Yoshihiro; Nishiyama, Hideyoshi; Nihara, Jun; Tanaka, Ray; Yamaki, Masaki; Hayashi, Takafumi; Saito, Isao

    2013-01-01

    Materials including facial and oral pictures, frontal and lateral cephalograms, dental casts and CT are essential for orthodontic diagnosis with orthognathic surgery. Although a three-dimensional analysis has been prevalent in diagnosing patients with dentofacial deformity, little information is available as to the definition and reproducibility of the measurement points when conducting a three-dimensional analysis using CT. This study was therefore designed to evaluate reproducibility of three-dimensional landmarks defined on the multiplaner reconstruction (MPR) images. Seven presurgical CT data obtained from seven orthognathic patients (4 females and 3 males) were selected. Two orthodontists independently repeated the identification of 44 landmarks defined twice on the MPR image with the reference plane of the Frankfurt horizontal plane (FH plane) using DICOM viewer Exavision Lite (Ziosoft, Tokyo). The significance of intra-examiner and inter-examiner errors was assessed using ANOVA, and reproducibility of landmarks was evaluated by the standard deviation (SD) value of measurement error. While no significant differences were found in intra-examiner measurement values, a significant difference was identified in inter-examiner measurement values at 39 coordinates among 132 coordinates; 10, 15, and 14 coordinates were found in X-, Y- and Z-coordinates, respectively. Reproducibility of ramus posterior point (Ar), Gonion (Go) and greater palatine foramen were particularly poor. However, reproducibility of landmarks adopted was considered enough for the analysis of maxillofacial morphology since the SDs of those landmarks were small as compared to voxel size. In case the FH plane is set as the reference plane, much more reproducible measurement landmarks may be selected without an influence of changes in head posture. (author)

  3. Three-dimensional CT pyelography for planning of percutaneous nephrostolithotomy: accuracy of stone measurement, stone depiction and pelvicalyceal reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Uday [St George' s Hospital and Medical School, Department of Radiology, London (United Kingdom); Princess Grace Hospital, London (United Kingdom); Walkden, Richard Miles [St George' s Hospital and Medical School, Department of Radiology, London (United Kingdom); Ghani, Khurshid R. [St George' s Hospital and Medical School, Department of Urology, London (United Kingdom); Anson, Ken [St George' s Hospital and Medical School, Department of Urology, London (United Kingdom); Princess Grace Hospital, London (United Kingdom)

    2009-05-15

    Retrospective evaluation of computed tomographic (CT) pyelography before percutaneous nephrostolithotomy (PCNL). Twenty patients with renal calculi underwent CT pyelography using a dedicated protocol. Calculus size, uniformity of contrast excretion and accuracy of calculus and pelvicalyceal (PC) system reconstructions were scored and compared on axial and coronal maximum intensity projections (MIP) and volume reconstructions (VRmovie loops). After contrast medium administration, the size of calculi is accurate on axial images, but underestimated on coronal studies: mean 14.7 mm vs. 14.4 mm (axial) and 17.2 mm vs. 16.1 mm (coronal) for measurements before and after enhancement, respectively (p = 0.11 and 0.03). Uniform contrast medium excretion (median 228 HU; 95% CI 209-266 HU) was sufficiently lower than calculus density (median 845 HU; 95% CI 457-1,193 HU) for precise calculus and pelvicalyceal reconstructions in 87% and 85%, respectively. Coronal MIP scans were rated best for calculus depiction (mean score 2.68 vs. 2.50 and 2.41 for coronal, axial and VRs, respectively; p = 0.14) and VR studies best for PC anatomy (mean score 4.4 vs. 3.73 and 2.89 for VR, coronal and axial studies, respectively; p = <0.0001). Three-dimensional CT pyelography can accurately demonstrate calculus position and spatial relationships of the collecting system before PCNL. (orig.)

  4. Three-dimensional CT pyelography for planning of percutaneous nephrostolithotomy: accuracy of stone measurement, stone depiction and pelvicalyceal reconstruction

    International Nuclear Information System (INIS)

    Patel, Uday; Walkden, Richard Miles; Ghani, Khurshid R.; Anson, Ken

    2009-01-01

    Retrospective evaluation of computed tomographic (CT) pyelography before percutaneous nephrostolithotomy (PCNL). Twenty patients with renal calculi underwent CT pyelography using a dedicated protocol. Calculus size, uniformity of contrast excretion and accuracy of calculus and pelvicalyceal (PC) system reconstructions were scored and compared on axial and coronal maximum intensity projections (MIP) and volume reconstructions (VRmovie loops). After contrast medium administration, the size of calculi is accurate on axial images, but underestimated on coronal studies: mean 14.7 mm vs. 14.4 mm (axial) and 17.2 mm vs. 16.1 mm (coronal) for measurements before and after enhancement, respectively (p = 0.11 and 0.03). Uniform contrast medium excretion (median 228 HU; 95% CI 209-266 HU) was sufficiently lower than calculus density (median 845 HU; 95% CI 457-1,193 HU) for precise calculus and pelvicalyceal reconstructions in 87% and 85%, respectively. Coronal MIP scans were rated best for calculus depiction (mean score 2.68 vs. 2.50 and 2.41 for coronal, axial and VRs, respectively; p = 0.14) and VR studies best for PC anatomy (mean score 4.4 vs. 3.73 and 2.89 for VR, coronal and axial studies, respectively; p = <0.0001). Three-dimensional CT pyelography can accurately demonstrate calculus position and spatial relationships of the collecting system before PCNL. (orig.)

  5. Three dimensional analysis of CT image on naso-maxillary complex in cleft lip and palate patients

    International Nuclear Information System (INIS)

    Ma, Rong-Rong

    1994-01-01

    This study was designed to clarify the three dimensional features of naso-maxillary complex in cleft lip and palate (CLP) by using computed tomography (CT) and to examine its change following an upper dental arch expansion. Sequential CT images with 2mm-thickness were obtained for 11 unilateral CLP boys (UCLP), 6 bilateral CLP boys (BCLP) and 4 boys without cleft (non-cleft). Additionally, two serial sets of upper dental cast before and after dental arch expansion coupled with CT images in UCLP were used to evaluate the effect of dental arch expansion on the naso-maxillary complex. UCLP demonstrated a remarkable naso-maxillary deformity characterized by a decreased volume of maxillary sinus in comparison with the non-cleft patients. Both the volume and shape of nasal cavity were significantly different between the cleft and non cleft side. Naso-maxillary morphology of BCLP, however, was similar to that of the non cleft except for the decreased volume of alveolar arch. Comparative study of UCLP and BCLP showed a significant difference in naso-maxillary morphology. There were some significant correlations between the dental arch expansion and change of each naso-maxillary component, suggesting the effect of expansion stress on the naso-maxillary complex in UCLP. However, deformation caused by expansion stress varied, depending on each component of the naso-maxillary complex. (author) 61 refs

  6. Reduction of metal artifact in three-dimensional computed tomography (3D CT) with dental impression materials.

    Science.gov (United States)

    Park, W S; Kim, K D; Shin, H K; Lee, S H

    2007-01-01

    Metal Artifact still remains one of the main drawbacks in craniofacial Three-Dimensional Computed Tomography (3D CT). In this study, we tried to test the efficacy of additional silicone dental impression materials as a "tooth shield" for the reduction of metal artifact caused by metal restorations and orthodontic appliances. 6 phantoms with 4 teeth were prepared for this in vitro study. Orthodontic bracket, bands and amalgam restorations were placed in each tooth to reproduce various intraoral conditions. Standardized silicone shields were fabricated and placed around the teeth. CT image acquisition was performed with and without silicone shields. Maximum value, mean, and standard deviation of Hounsfield Units (HU) were compared with the presence of silicone shields. In every situation, metal artifacts were reduced in quality and quantity when silicone shields are used. Amalgam restoration made most serious metal artifact. Silicone shields made by dental impression material might be effective way to reduce the metal artifact caused by dental restoration and orthodontic appliances. This will help more excellent 3D image from 3D CT in craniofacial area.

  7. Three dimensional analysis of CT image on naso-maxillary complex in cleft lip and palate patients

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Rong-Rong [Tokyo Medical and Dental Univ. (Japan). School of Dentistry

    1994-12-01

    This study was designed to clarify the three dimensional features of naso-maxillary complex in cleft lip and palate (CLP) by using computed tomography (CT) and to examine its change following an upper dental arch expansion. Sequential CT images with 2mm-thickness were obtained for 11 unilateral CLP boys (UCLP), 6 bilateral CLP boys (BCLP) and 4 boys without cleft (non-cleft). Additionally, two serial sets of upper dental cast before and after dental arch expansion coupled with CT images in UCLP were used to evaluate the effect of dental arch expansion on the naso-maxillary complex. UCLP demonstrated a remarkable naso-maxillary deformity characterized by a decreased volume of maxillary sinus in comparison with the non-cleft patients. Both the volume and shape of nasal cavity were significantly different between the cleft and non cleft side. Naso-maxillary morphology of BCLP, however, was similar to that of the non cleft except for the decreased volume of alveolar arch. Comparative study of UCLP and BCLP showed a significant difference in naso-maxillary morphology. There were some significant correlations between the dental arch expansion and change of each naso-maxillary component, suggesting the effect of expansion stress on the naso-maxillary complex in UCLP. However, deformation caused by expansion stress varied, depending on each component of the naso-maxillary complex. (author) 61 refs.

  8. Study of guided modes in three-dimensional composites

    Science.gov (United States)

    Baste, S.; Gerard, A.

    The propagation of elastic waves in a three-dimensional carbon-carbon composite is modeled with a mixed variational method, using the Bloch or Floquet theories and the Hellinger-Reissner function for two independent fields. The model of the equivalent homogeneous material only exists below a cut-off frequency of about 600 kHz. The existence below the cut-off frequency of two guided waves can account for the presence of a slow guided wave on either side of the cut-off frequency. Optical modes are generated at low frequencies, and can attain high velocites (rapid guided modes of 15,000 m/sec).

  9. Standardization of MIP technique in three-dimensional CT portography: usefulness in evaluation of portosystemic collaterals in cirrhotic patients

    International Nuclear Information System (INIS)

    Kim, Jong Gi; Kim, Yong; Kim, Chang Won; Lee, Jun Woo; Lee, Suk Hong

    2003-01-01

    To assess the usefulness of three-dimensional CT portography using a standardized maximum intensity projection (MIP) technique for the evaluation of portosystemic collaterals in cirrhotic patients. In 25 cirrhotic patients with portosystemic collaterals, three-phase CT using a multide-tector-row helical CT scanner was performed to evaluate liver disease. Late arterial-phase images were transferred to an Advantage Windows 3.1 workstation (Gener Electric). Axial images were reconstructed by means of three-dimensional CT portography, using both a standardized and a non-standardized MIP technique, and the respective reconstruction times were determined. Three-dimensional CT portography with the standardized technique involved eight planes, namely the spleno-portal confluence axis (coronal, lordotic coronal, lordotic coronal RAO 30 .deg. C, and lordotic coronal LAO 30 .deg. C), the left renal vein axis (lordotic coronal), and axial MIP images (lower esophagus level, gastric fundus level and splenic hilum). The eight MIP images obtained in each case were interpreted by two radiologists, who reached a consensus in their evaluation. The portosystemic collaterals evaluated were as follows: left gastric vein dilatation; esophageal, paraesophageal, gastric, and splenic varix; paraumbilical vein dilatation; gastro-renal, spleno-renal, and gastro-spleno-renal shunt; mesenteric, retroperitoneal, and omental collaterals. The average reconstruction time using the non-standardized MIP technique was 11 minutes 23 seconds, and with the standardized technique, the time was 6 minutes 5 seconds. Three-dimensional CT portography with the standardized technique demonstrated left gastric vein dilatation (n=25), esophageal varix (n=18), paraesophageal varix (n=13), gastric varix (n=4), splenic varix (n=4), paraumbilical vein dilatation (n=4), gastro-renal shunt (n=3), spleno-renal shunt (n=3), and gastro-spleno-renal shunt (n=1). Using three-dimensional CT protography and the non

  10. Deviation of landmarks in accordance with methods of establishing reference planes in three-dimensional facial CT evaluation.

    Science.gov (United States)

    Yoon, Kaeng Won; Yoon, Suk-Ja; Kang, Byung-Cheol; Kim, Young-Hee; Kook, Min Suk; Lee, Jae-Seo; Palomo, Juan Martin

    2014-09-01

    This study aimed to investigate the deviation of landmarks from horizontal or midsagittal reference planes according to the methods of establishing reference planes. Computed tomography (CT) scans of 18 patients who received orthodontic and orthognathic surgical treatment were reviewed. Each CT scan was reconstructed by three methods for establishing three orthogonal reference planes (namely, the horizontal, midsagittal, and coronal reference planes). The horizontal (bilateral porions and bilateral orbitales) and midsagittal (crista galli, nasion, prechiasmatic point, opisthion, and anterior nasal spine) landmarks were identified on each CT scan. Vertical deviation of the horizontal landmarks and horizontal deviation of the midsagittal landmarks were measured. The porion and orbitale, which were not involved in establishing the horizontal reference plane, were found to deviate vertically from the horizontal reference plane in the three methods. The midsagittal landmarks, which were not used for the midsagittal reference plane, deviated horizontally from the midsagittal reference plane in the three methods. In a three-dimensional facial analysis, the vertical and horizontal deviations of the landmarks from the horizontal and midsagittal reference planes could vary depending on the methods of establishing reference planes.

  11. Deviation of landmarks in accordance with methods of establishing reference planes in three-dimensional facial CT evaluation

    International Nuclear Information System (INIS)

    Yoon, Kaeng Won; Yoon, Suk Ja; Kang, Byung Cheol; Kook, Min Suk; Lee, Jae Seo; Kim, Young Hee; Palomo, Juan Martin

    2014-01-01

    This study aimed to investigate the deviation of landmarks from horizontal or midsagittal reference planes according to the methods of establishing reference planes. Computed tomography (CT) scans of 18 patients who received orthodontic and orthognathic surgical treatment were reviewed. Each CT scan was reconstructed by three methods for establishing three orthogonal reference planes (namely, the horizontal, midsagittal, and coronal reference planes). The horizontal (bilateral porions and bilateral orbitales) and midsagittal (crista galli, nasion, prechiasmatic point, opisthion, and anterior nasal spine) landmarks were identified on each CT scan. Vertical deviation of the horizontal landmarks and horizontal deviation of the midsagittal landmarks were measured. The porion and orbitale, which were not involved in establishing the horizontal reference plane, were found to deviate vertically from the horizontal reference plane in the three methods. The midsagittal landmarks, which were not used for the midsagittal reference plane, deviated horizontally from the midsagittal reference plane in the three methods. In a three-dimensional facial analysis, the vertical and horizontal deviations of the landmarks from the horizontal and midsagittal reference planes could vary depending on the methods of establishing reference planes.

  12. Deviation of landmarks in accordance with methods of establishing reference planes in three-dimensional facial CT evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Kaeng Won; Yoon, Suk Ja; Kang, Byung Cheol; Kook, Min Suk; Lee, Jae Seo [School of Dentistry, Dental Science Research Institute, Chonnam National University, Gwangju (Korea, Republic of); Kim, Young Hee [Dept. of Oral and Maxillofacial Radiology, Hallym University Sacred Heart Hospital, Anyang (Korea, Republic of); Palomo, Juan Martin [Dept. of Orthodontics, School of Dental Medicine, Case Western Reserve University, Cleveland (Korea, Republic of)

    2014-09-15

    This study aimed to investigate the deviation of landmarks from horizontal or midsagittal reference planes according to the methods of establishing reference planes. Computed tomography (CT) scans of 18 patients who received orthodontic and orthognathic surgical treatment were reviewed. Each CT scan was reconstructed by three methods for establishing three orthogonal reference planes (namely, the horizontal, midsagittal, and coronal reference planes). The horizontal (bilateral porions and bilateral orbitales) and midsagittal (crista galli, nasion, prechiasmatic point, opisthion, and anterior nasal spine) landmarks were identified on each CT scan. Vertical deviation of the horizontal landmarks and horizontal deviation of the midsagittal landmarks were measured. The porion and orbitale, which were not involved in establishing the horizontal reference plane, were found to deviate vertically from the horizontal reference plane in the three methods. The midsagittal landmarks, which were not used for the midsagittal reference plane, deviated horizontally from the midsagittal reference plane in the three methods. In a three-dimensional facial analysis, the vertical and horizontal deviations of the landmarks from the horizontal and midsagittal reference planes could vary depending on the methods of establishing reference planes.

  13. Three-dimensional modeling and simulation of asphalt concrete mixtures based on X-ray CT microstructure images

    Directory of Open Access Journals (Sweden)

    Hainian Wang

    2014-02-01

    Full Text Available X-ray CT (computed tomography was used to scan asphalt mixture specimen to obtain high resolution continuous cross-section images and the meso-structure. According to the theory of three-dimensional (3D reconstruction, the 3D reconstruction algorithm was investigated in this paper. The key to the reconstruction technique is the acquisition of the voxel positions and the relationship between the pixel element and node. Three-dimensional numerical model of asphalt mixture specimen was created by a self-developed program. A splitting test was conducted to predict the stress distributions of the asphalt mixture and verify the rationality of the 3D model.

  14. Multi-slice CT three dimensional volume measurement of tumors and livers in hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Yu Yuanlong; Li Liangcai; Tang Binghang; Hu Zemin

    2004-01-01

    Objective: To examine the accuracy of multi-slice CT (MSCT) three dimensional (3D) volume measurement of tumors and livers in hepatocellular carcinoma cases by using immersion method as the standard. Methods: (1) The volume of 25 porkling livers was measured using immersion method in experiment group in vitro. Then the models were built according to Matsumoto's method and CT scanning and special software were used to measure the volume of the livers. (2) The volume of the tumors in 25 cases of hepatocellular carcinoma was measured using diameter measurement method and special volume measurement software (tissue measurements). Two tumors of them were measured respectively using MSCT 3D measurement, diameter measurement before the operation and immersion method after the operation. The data of the two groups were examined using pairing t test. Results: (1) The volume range of 25 porkling livers was 68.50-1150.10 ml using immersion method and 69.78-1069.97 ml using MSCT 3D measurement. There was no significant difference of the data in these two groups using t-test (t=1.427, P>0.05). (2) The volume range of 25 hepatocellular tumors was 395.16-2747.7 ml using diameter measurement and 203.10-1463.19 ml using MSCT 3D measurement before the operation. There was significant difference of the data in these two groups using t-test (t=7.689, P<0.001). In 2 ablated tumors, 1 case's volume was (21.75±0.60) ml using MSCT 3D measurement and 33.73 ml using diameter measurement before the operation and 21.50 ml using immersion measurement after the operation. The other case's volume was (696.13±5.30) ml using MSCT 3D measurement and 1323.51 ml using diameter measurement before the operation and 685.50 ml using immersion measurement after the operation. Conclusion: MSCT 3D volume measurement can accurately measure the volume of tumor and liver and has important clinical application value. There is no significant difference between MSCT 3D volume measurement and immersion method

  15. Three-dimensional CT virtual endoscopy in the detection of simulated tumors in a novel phantom bladder and ureter model.

    Science.gov (United States)

    Russell, Shane T; Kawashima, Akira; Vrtiska, Terri J; LeRoy, Andrew J; Bruesewitz, Michael R; Hartman, Robert P; Slezak, Jeffrey M; McCollough, Cynthia H; Chow, George K; King, Bernard F

    2005-03-01

    Cystoscopy and ureteroscopy have limitations in the evaluation for urothelial tumors, and both are invasive. We studied the utility of three-dimensional (3D) CT virtual endoscopy in phantom models. A phantom pelvis was constructed of Plexiglas, porcine pelvic bones, and processed animal fat and scanned at various table speeds in a four detector-row CT machine for ability to detect "tumors" of Solidwater plastic polymer. Images were reconstructed at slice thicknesses of 2.5 to 5.0 mm and reconstructed in 3D for evaluation by two radiologists with no knowledge of the scanning parameters or tumor location. Similar studies were performed with a ureter model. With 5-mm slices, the sensitivity for bladder tumors ranged from 67% for 2-mm tumors to 100% for 4-mm tumors, with 12 false-positive findings. The overall sensitivity was 86% with 3.75-mm slices with one false positive, and with 2.5-mm slices, the sensitivity was 93%, again with one false positive. For the ureteral tumors, the overall sensitivities and numbers of false positives were 88.9% and eight with 5.0-mm collimation, 88.9% and four with 3.75-mm collimation, and 100% and three with 2.5-mm collimation. The effective radiation dose for all studies was equivalent to that of a standard abdomen/pelvis scan. Although virtual endoscopy traditionally has had difficulty detecting tumors <5 mm, the multidetector-row CT protocols used in this study could detect most lesions smaller than this. The scan also depicts the other tissues of the pelvis, which is valuable for staging. The 3D images were produced using data from the CT urogram parameters standard at our institution.

  16. A three-dimensional CT-based target definition for elective irradiation of the neck

    International Nuclear Information System (INIS)

    Nowak, Peter J.C.M.; Wijers, Oda B.; Lagerwaard, Frank J.; Levendag, Peter C.

    1999-01-01

    Introduction: Elective treatment of the clinically node-negative neck by radiation results in excellent control rates. However, radiation therapy with its organ-preserving properties is not without morbidity. Side effects of elective neck irradiation are mainly due to damage of the major and minor salivary glands, resulting in the dry mouth syndrome. Given that RT is the preferred treatment modality in case of elective treatment of the neck in many institutions, it is of utmost importance to try and reduce the associated sequelae of RT. Material and Methods: With the introduction of CT-planning systems and the development of 3D conformal radiation therapy (3D CRT) techniques, it has become feasible to deliver adequate doses of radiation to the target (neck) and at the same time saving (parts of) the salivary glands from doses beyond tolerance. A prerequisite for these techniques is that they require a precise knowledge of the target (i.e., of the elective neck) on CT. To be able to correlate borders of the surgical levels in the neck (I-VI) with structures seen on CT, an anatomical study, using two fixed (phenol, formaldehyde) human cadavers, was performed. Subsequently, the 6 potential lymph node regions in the neck on CT were defined. Results and Discussion: The reference for the current 3D CT-based definition of the lymph node regions in the neck is the official report of the American Academy of Otolaryngology, describing, based on surgical anatomy, the lymph node groups in the neck by Levels I-VI. The present investigation depicts reproducible landmarks on transversal CT images, corresponding to anatomical reference structures known from surgical levels (I-VI) and, this way, CT-based lymph node regions (1-6) were constructed

  17. Three-Dimensional Imaging Using Microcomputed Tomography For Studying Gaharu Morphology

    International Nuclear Information System (INIS)

    Yazid, Khair'iah; Bin Awang, Mat Rasol; Mohamed, Abdul Aziz; Bin Hj Khalid, Mohd Ashhar; Masschaele, Bert; Abdullah, Mohd. Zaid; Saleh, Junita Mohamad

    2010-01-01

    To demonstrates the potential application of the high resolution X-ray micro-CT technique in the analysis of internal structure in Gaharu wood. Gaharu or internationally, Agar wood, is known for its fragrant resinous wood. The hardware device used in this study was an X-ray micro-CT scanner at Center of Tomography (UGCT), CT facility in Ghent University, Belgium. This technique allows the 3D investigation of the internal structure of the wood in a non-destructive way. Most of the data analysis was done with the software VG Studio Max and MATLAB. Here we present some preliminary results from three-dimensional images from a piece of high grade Gaharu. Micro-CT images of the specimens were obtained at 7 μm resolution. Besides a clear distinction between pores and material, some bright white areas occur in the reconstruction images. Not only the volume visualization is helpful, morphological parameters of open-pores and dark resins are calculated from these 3D data set. The micro-CT technique is a valid support for evaluating the pores structure and resin distribution in Gaharu.

  18. Three-dimensional image analysis of a head of the giant panda by the cone-beam type CT

    International Nuclear Information System (INIS)

    Endo, H.; Komiya, T.; Narushima, E.; Suzuki, N.

    2002-01-01

    The cone-beam type CT (Computed Tomography) enabled us to collect the three-dimensional (3D) digitalized data directly from the animal carcass. In this study, we applied the techniques of the cone-beam type CT for a carcass head of the giant panda (Ailuropoda melanoleuca) to obtain the 3D images easily without reconstruction process, and could morphologically examine the sections from the 3D data by means of non-destructive observations. The important results of the study represent the two following points. 1) We could show the morphological relationships between the muscles of mastication and the mandible in non-destructive status from the 3D data. The exact position of the coronoid process could be recognized in the rostro-lateral space of the temporal fossa. 2) By the serial sections from the 3D data sets, the morphological characteristics in the nasal cavity were detailed with high resolution in this rare species. The nasal concha was well-developed in the nasal cavity. The ethmoidal labyrinth was encountered immediately caudal to the nasal cavity and close to the region of the olfactory bulb. The ethmoidal labyrinth consisted of the complicated osseous structure in this area. The data will be useful to discuss the olfactory function in the reproduction behavior of this species

  19. Three-dimensional fracture visualisation of multidetector CT of the skull base in trauma patients: comparison of three reconstruction algorithms

    International Nuclear Information System (INIS)

    Ringl, Helmut; Schernthaner, Ruediger; Philipp, Marcel O.; Metz-Schimmerl, Sylvia; Czerny, Christian; Weber, Michael; Steiner-Ringl, Andrea; Peloschek, Philipp; Herold, Christian J.; Schima, Wolfgang; Gaebler, Christian

    2009-01-01

    The purpose of this study was to retrospectively assess the detection rate of skull-base fractures for three different three-dimensional (3D) reconstruction methods of cranial CT examinations in trauma patients. A total of 130 cranial CT examinations of patients with previous head trauma were subjected to 3D reconstruction of the skull base, using solid (SVR) and transparent (TVR) volume-rendering technique and maximum intensity projection (MIP). Three radiologists independently evaluated all reconstructions as well as standard high-resolution multiplanar reformations (HR-MPRs). Mean fracture detection rates for all readers reading rotating reconstructions were 39, 36, 61 and 64% for SVR, TVR, MIP and HR-MPR respectively. Although not significantly different from HR-MPR with respect to sensitivity (P = 0.9), MIP visualised 18% of fractures that were not reported in HR-MPR. Because of the relatively low detection rate using HR-MPRs alone, we recommend reading MIP reconstructions in addition to the obligatory HR-MPRs to improve fracture detection. (orig.)

  20. Three-dimensional renal CT angiography for guiding segmental renal artery clamping during laparoscopic partial nephrectomy

    International Nuclear Information System (INIS)

    Xu, Yi; Shao, Pengfei; Zhu, Xiaomei; Lv, Qiang; Liu, Wangyan; Xu, Hai; Zhu, Yinsu; Yang, Guangyu; Tang, Lijun; Yin, Changjun

    2013-01-01

    Aim: To evaluate the effectiveness of three-dimensional (3D) renal computed tomography angiography (CTA) in guiding segmental renal artery clamping during laparoscopic partial nephrectomy (LPN). Materials and methods: Forty-three patients with renal tumours undergoing renal CTA before LPN were retrospectively enrolled in this study. 3D arteriogram reconstructed images were created to identify the renal tumour-supplying arteries. The number and location of these targeted vessels were annotated on 3D images preoperatively and compared with the clamped vessels during LPN. The consistency between target vessels annotated at CTA and clamped arteries at LPN was compared both using a patient-based analysis and vessel-based analysis. The χ 2 test was applied to analyse the influence of tumour size, location, and growth pattern on the number of clamped segmental renal branches. Results: On patient-based analysis, the number of targeted vessels was consistent with the clamped vessels during LPN in 33 of 43 patients. On vessel-based analysis, 56 of 65 target vessels annotated at CTA were clamped during LPN. More segmental renal branches (p = 0.04) were clamped in patients with tumours of larger size. Tumour location and growth pattern had no association with the number of clamped segmental branches during LPN. Conclusion: High-quality CTA images and 3D reconstruction images can detect detailed information of tumour-supplying arteries to renal tumours. 3D renal CTA is an effective way to guide segmental renal artery clamping during LPN

  1. Three dimensional simulation study of spheromak injection into magnetized plasmas

    International Nuclear Information System (INIS)

    Suzuki, Y.; Watanabe, T.H.; Sato, T.; Hayashi, T.

    2000-01-01

    The three dimensional dynamics of a spheromak-like compact toroid (SCT) plasmoid, which is injected into a magnetized target plasma region, is investigated by using MHD numerical simulations. It is found that the process of SCT penetration into this region is much more complicated than that which has been analysed so far by using a conducting sphere (CS) model. The injected SCT suffers from a tilting instability, which grows with a similar timescale to that of the SCT penetration. The instability is accompanied by magnetic reconnection between the SCT magnetic field and the target magnetic field, which disrupts the magnetic configuration of the SCT. Magnetic reconnection plays a role in supplying the high density plasma, initially confined in the SCT magnetic field, to the target region. The penetration depth of the SCT high density plasma is also examined. It is shown to be shorter than that estimated from the CS model. The SCT high density plasma is decelerated mainly by the Lorentz force of the target magnetic field, which includes not only the magnetic pressure force but also the magnetic tension force. Furthermore, by comparing the SCT plasmoid injection with the bare plasmoid injection, magnetic reconnection is considered to relax the magnetic tension force, i.e. the deceleration of the SCT plasmoid. (author)

  2. Computer-assisted three-dimensional reconstruction of the corticospinal system as a reference for CT and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Buhmann, C. [Department of Neuroanatomy, Hannover Medical School (Germany)]|[University Hospital Eppendorf, Hamburg (Germany); Kretschmann, H.J. [Department of Neuroanatomy, Hannover Medical School (Germany)

    1998-09-01

    We present a three-dimensional (3D) anatomical computer-graphics model of the corticospinal system acquired from equidistant serial anatomical slices of six intracranially-fixed human brains. This model is part of a neuroanatomical reference system (NeuRef) which enables 3D visualization of the brain and shows the relationship of its components such as anatomical structures, functional fibre tracts and arteries. Sections through the models can be matched with corresponding CT or MR images. This allows the probable localisation of corticospinal fibres on CT or MRI. (orig.) (orig.) With 18 figs., 3 tabs., 40 refs.

  3. Computer-assisted three-dimensional reconstruction of the corticospinal system as a reference for CT and MRI

    International Nuclear Information System (INIS)

    Buhmann, C.; Kretschmann, H.J.

    1998-01-01

    We present a three-dimensional (3D) anatomical computer-graphics model of the corticospinal system acquired from equidistant serial anatomical slices of six intracranially-fixed human brains. This model is part of a neuroanatomical reference system (NeuRef) which enables 3D visualization of the brain and shows the relationship of its components such as anatomical structures, functional fibre tracts and arteries. Sections through the models can be matched with corresponding CT or MR images. This allows the probable localisation of corticospinal fibres on CT or MRI. (orig.) (orig.)

  4. Predicting Peri-Device Leakage of Left Atrial Appendage Device Closure Using Novel Three-Dimensional Geometric CT Analysis.

    Science.gov (United States)

    Chung, Hyemoon; Jeon, Byunghwan; Chang, Hyuk-Jae; Han, Dongjin; Shim, Hackjoon; Cho, In Jeong; Shim, Chi Young; Hong, Geu-Ru; Kim, Jung-Sun; Jang, Yangsoo; Chung, Namsik

    2015-12-01

    After left atrial appendage (LAA) device closure, peri-device leakage into the LAA persists due to incomplete occlusion. We hypothesized that pre-procedural three-dimensional (3D) geometric analysis of the interatrial septum (IAS) and LAA orifice can predict this leakage. We investigated the predictive parameters of LAA device closure obtained from baseline cardiac computerized tomography (CT) using a novel 3D analysis system. We conducted a retrospective study of 22 patients who underwent LAA device closure. We defined peri-device leakage as the presence of a Doppler signal inside the LAA after device deployment (group 2, n = 5) compared with patients without peri-device leakage (group 1, n = 17). Conventional parameters were measured by cardiac CT. Angles θ and φ were defined between the IAS plane and the line, linking the LAA orifice center and foramen ovale. Group 2 exhibited significantly better left atrial (LA) function than group 1 (p = 0.031). Pre-procedural θ was also larger in this group (41.9° vs. 52.3°, p = 0.019). The LAA cauliflower-type morphology was more common in group 2. Overall, the patients' LA reserve significantly decreased after the procedure (21.7 mm(3) vs. 17.8 mm(3), p = 0.035). However, we observed no significant interval changes in pre- and post-procedural values of θ and φ in either group (all p > 0.05). Angles between the IAS and LAA orifice might be a novel anatomical parameter for predicting peri-device leakage after LAA device closure. In addition, 3D CT analysis of the LA and LAA orifice could be used to identify clinically favorable candidates for LAA device closure.

  5. Three-dimensional visualization and measurement of water distributions in PEFC by dynamic CT method on neutron radiography

    International Nuclear Information System (INIS)

    Hashimoto, Michinori; Murakawa, Hideki; Sugimoto, Katsumi; Asano, Hitoshi; Takenaka, Nobuyuki; Mochiki, Koh-ichi

    2011-01-01

    Visualization of dynamic three-dimensional water behavior in a PEFC stack was carried out by neutron CT for clarifying water effects on performances of a Polymer Electrolyte Fuel Cell (PEFC) stack. Neutron radiography system at JRR-3 in Japan Atomic Energy Agency was used. An operating stack with three cells based on Japan Automobile Research Institute standard was visualized. A consecutive CT reconstruction method by rotating the fuel stack continuously was developed by using a neutron image intensifier and a C-MOS high speed video camera. The dynamic water behavior in channels in the operating PEFC stack was clearly visualized 15 sec in interval by the developed dynamic neutron CT system. From the CT reconstructed images, evaluation of water amount in each cell was carried out. It was shown that the water distribution in each cell was correlated well with power generation characteristics in each cell. (author)

  6. Three-dimensional spiral CT during arterial portography: comparison of three rendering techniques.

    Science.gov (United States)

    Heath, D G; Soyer, P A; Kuszyk, B S; Bliss, D F; Calhoun, P S; Bluemke, D A; Choti, M A; Fishman, E K

    1995-07-01

    The three most common techniques for three-dimensional reconstruction are surface rendering, maximum-intensity projection (MIP), and volume rendering. Surface-rendering algorithms model objects as collections of geometric primitives that are displayed with surface shading. The MIP algorithm renders an image by selecting the voxel with the maximum intensity signal along a line extended from the viewer's eye through the data volume. Volume-rendering algorithms sum the weighted contributions of all voxels along the line. Each technique has advantages and shortcomings that must be considered during selection of one for a specific clinical problem and during interpretation of the resulting images. With surface rendering, sharp-edged, clear three-dimensional reconstruction can be completed on modest computer systems; however, overlapping structures cannot be visualized and artifacts are a problem. MIP is computationally a fast technique, but it does not allow depiction of overlapping structures, and its images are three-dimensionally ambiguous unless depth cues are provided. Both surface rendering and MIP use less than 10% of the image data. In contrast, volume rendering uses nearly all of the data, allows demonstration of overlapping structures, and engenders few artifacts, but it requires substantially more computer power than the other techniques.

  7. In Vivo CT Direct Volume Rendering: A Three-Dimensional Anatomical Description of the Heart

    International Nuclear Information System (INIS)

    Cutroneo, Giuseppina; Bruschetta, Daniele; Trimarchi, Fabio; Cacciola, Alberto; Cinquegrani, Maria; Duca, Antonio; Rizzo, Giuseppina; Alati, Emanuela; Gaeta, Michele; Milardi, Demetrio

    2016-01-01

    Since cardiac anatomy continues to play an important role in the practice of medicine and in the development of medical devices, the study of the heart in three dimensions is particularly useful to understand its real structure, function and proper location in the body. This study demonstrates a fine use of direct volume rendering, processing the data set images obtained by Computed Tomography (CT) of the heart of 5 subjects with age range between 18 and 42 years (2 male, 3 female), with no history of any overt cardiac disease. The cardiac structure in CT images was first extracted from the thorax by marking manually the regions of interest on the computer, and then it was stacked to create new volumetric data. The use of a specific algorithm allowed us to observe with a good perception of depth the heart and the skeleton of the thorax at the same time. Besides, in all examined subjects, it was possible to depict its structure and its position within the body and to study the integrity of papillary muscles, the fibrous tissue of cardiac valve and chordae tendineae and the course of coronary arteries. Our results demonstrated that one of the greatest advantages of algorithmic modifications of direct volume rendering parameters is that this method provides much necessary information in a single radiologic study. It implies a better accuracy in the study of the heart, being complementary to other diagnostic methods and facilitating the therapeutic plans

  8. Three-dimensional simulation study of compact toroid injection into magnetized plasmas

    International Nuclear Information System (INIS)

    Yoshio Suzuki; Tomohiko Watanabe; Tetsuya Sato; Takaya Hayashi

    1999-01-01

    Three-dimensional dynamics of a compact toroid (CT), which is injected into a magnetized target plasma modeling a part of a fusion device is investigated by using magnetohydrodynamic numerical simulations. It is found that the injected CT penetrates into the device region, suffering from a tilting instability. In this process, magnetic reconnection between the CT magnetic field and the device magnetic field takes place, which disrupts the magnetic configuration of the CT. As a result, the high density plasma confined in the CT magnetic field is locally supplied in the device region. Furthermore, the authors examine the penetration depth of the CT high density plasma. And it is revealed that the CT high density plasma is decelerated by the device magnetic field through the compressional heating

  9. Detection of intracranial aneurysms using three-dimensional multidetector-row CT angiography: Is bone subtraction necessary?

    International Nuclear Information System (INIS)

    Hwang, Seung Bae; Kwak, Hyo Sung; Han, Young Min; Chung, Gyung Ho

    2011-01-01

    Purpose: The aim of this study was to evaluate the usefulness of three-dimensional CT angiography (3D CTA) with bone subtraction in a comparison with 3D CTA without bone subtraction for the detection of intracranial aneurysms. Materials and methods: Among 337 consecutive patients who had intracranial aneurysms detected on 3D CTA, 170 patients who underwent digital subtraction angiography (DSA) were included in the study. CTA was performed with a 16-slice multidetector-row CT (MDCT) scanner. We created the 3D reconstruction images with and without bone subtraction by using the volume rendering technique. Three neuroradiologists in a blinded fashion interpreted both 3D CTA images with and without bone subtraction. The diagnostic accuracy of both techniques was evaluated using the alternative free-response receiver operating characteristic (ROC) analysis. The sensitivity and positive predictive value were also evaluated. Results: A total of 200 aneurysms (size: 2-23 mm) were detected in 170 patients. The area under the receiver operating characteristic curve (Az) for 3D CTA with bone subtraction (mean, Az = 0.933) was significantly higher than that for 3D CTA without bone subtraction (mean, Az = 0.879) for all observers (P < 0.05). The sensitivity of 3D CTA with bone subtraction for three observers was 90.0, 92.0 and 92.5%, respectively, while the sensitivity of 3D CTA without bone subtraction was 83.5, 83.5 and 87.5%, respectively. No significant difference in positive predictive value was observed between the two modalities. Conclusions: 3D CTA with bone subtraction showed significantly higher diagnostic accuracy for the detection of intracranial aneurysms as compared to 3D CTA without bone subtraction.

  10. Three-dimensional automatic computer-aided evaluation of pleural effusions on chest CT images

    Science.gov (United States)

    Bi, Mark; Summers, Ronald M.; Yao, Jianhua

    2011-03-01

    The ability to estimate the volume of pleural effusions is desirable as it can provide information about the severity of the condition and the need for thoracentesis. We present here an improved version of an automated program to measure the volume of pleural effusions using regular chest CT images. First, the lungs are segmented using region growing, mathematical morphology, and anatomical knowledge. The visceral and parietal layers of the pleura are then extracted based on anatomical landmarks, curve fitting and active contour models. The liver and compressed tissues are segmented out using thresholding. The pleural space is then fitted to a Bezier surface which is subsequently projected onto the individual two-dimensional slices. Finally, the volume of the pleural effusion is quantified. Our method was tested on 15 chest CT studies and validated against three separate manual tracings. The Dice coefficients were 0.74+/-0.07, 0.74+/-0.08, and 0.75+/-0.07 respectively, comparable to the variation between two different manual tracings.

  11. Three-dimensional biplanar radiography as a new means of accessing femoral version: a comparitive study of EOS three-dimensional radiography versus computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Pomerantz, M.L. [University of California San Diego School of Medicine, Orthopaedic Surgery Department, San Diego, CA (United States); Glaser, Diana [Aurora Spine, Carlsbad, CA (United States); Doan, Josh [Orthopedic Biomechanics Research Center, San Diego, CA (United States); Kumar, Sita [University of California, San Diego, CA (United States); Edmonds, Eric W. [University of California San Diego School of Medicine, Orthopaedic Surgery Department, San Diego, CA (United States); Rady Children' s Hospital San Diego, Division of Orthopedic Surgery, San Diego, CA (United States)

    2014-10-17

    To validate femoral version measurements made from biplanar radiography (BR), three-dimensional (3D) reconstructions (EOS imaging, France) were made in differing rotational positions against the gold standard of computed tomography (CT). Two cadaveric femurs were scanned with CT and BR in five different femoral versions creating ten total phantoms. The native version was modified by rotating through a mid-diaphyseal hinge twice into increasing anteversion and twice into increased retroversion. For each biplanar scan, the phantom itself was rotated -10, -5, 0, +5 and +10 . Three-dimensional CT reconstructions were designated the true value for femoral version. Two independent observers measured the femoral version on CT axial slices and BR 3D reconstructions twice. The mean error (upper bound of the 95 % confidence interval), inter- and intraobserver reliability, and the error compared to the true version were determined for both imaging techniques. Interobserver intraclass correlation for CT axial images ranged from 0.981 to 0.991, and the intraobserver intraclass correlation ranged from 0.994 to 0.996. For the BR 3D reconstructions these values ranged from 0.983 to 0.998 and 0.982 to 0.998, respectively. For the CT measurements the upper bound of error from the true value was 5.4-7.5 , whereas for BR 3D reconstructions it was 4.0-10.1 . There was no statistical difference in the mean error from the true values for any of the measurements done with axial CT or BR 3D reconstructions. BR 3D reconstructions accurately and reliably provide clinical data on femoral version compared to CT even with rotation of the patient of up to 10 from neutral. (orig.)

  12. Prenatal diagnosis of chondrodysplasia punctata tibia-metacarpal type using multidetector CT and three-dimensional reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Miyazaki, Osamu [National Centre for Child Health and Development, Department of Radiology, Tokyo (Japan); Nishimura, Gen [Tokyo Metropolitan Kiyose Children' s Hospital, Department of Radiology, Tokyo (Japan); Sago, Haruhiko; Watanabe, Noriyoshi; Ebina, Shunsuke [National Centre for Child Health and Development, Department of Perinatal Medicine and Maternal Care, Tokyo (Japan)

    2007-11-15

    We report a case of chondrodysplasia punctata tibia-metacarpal type (CDP-TM) that was diagnosed prenatally using multidetector CT (MDCT) with three-dimensional (3-D) CT reconstructions. Prenatal US had shown severe thoracic hypoplasia and rhizomelic shortening of the limbs, raising the suspicion of thanatophoric dysplasia. However, MDCT showed punctate calcifications in the epiphyseal cartilage of the humeri and femora, carpal bones, and paravertebral region. On 3-D CT, the tibiae were much shorter than the fibulae, the humeri were very short and bowed, and severe platyspondyly was evident. These findings led to the diagnosis of CDP-TM. The diagnosis was confirmed on postnatal radiographs. Prenatal MDCT with 3-D images may make a useful contribution to prenatal diagnosis in selected fetuses with severe skeletal dysplasia. (orig.)

  13. Creation and evaluation of complementary composite three-dimensional image in various brain diseases. An application of three-dimensional brain SPECT image and three-dimensional CT image

    International Nuclear Information System (INIS)

    Seiki, Yoshikatsu; Shibata, Iekado; Mito, Toshiaki; Sugo, Nobuo

    2000-01-01

    The purpose of this study was to develop 3D composite images for use in functional and anatomical evaluation of various cerebral pathologies. Imaging studies were performed in normal volunteers, patients with hydrocephalus and patients with brain tumor (meningioma and metastatic tumor) using a three-detector SPECT system (Prism 3000) and helical CT scanner (Xvigor). 123 I-IMP was used in normal volunteers and patients with hydrocephalus, and 201 TLCL in patients with brain tumor. An Application Visualization System-Medical Viewer (AVS-MV) was used on a workstation (Titan 2) to generate 3D images. A new program was developed by synthesizing surface rendering and volume rendering techniques. The clinical effects of shunt operations were successfully evaluated in patients with hydrocephalus by means of translucent 3D images of the deep brain. Changes in the hypoperfusion area around the cerebral ventricle were compared with morphological changes in the cerebral ventricle on CT. In addition to the information concerning the characteristics of brain tumors and surrounding edemas, hemodynamic changes and changeable hypoperfusion areas around the tumors were visualized on 3D composite CT and SPECT images. A new method of generating 3D composite images of CT and SPECT was developed by combining graphic data from different systems on the same workstation. Complementary 3D composite images facilitated quantitative analysis of brain volume and functional analysis in various brain diseases. (author)

  14. Pre-operative evaluation of cleft palate using three dimensional computerized tomography (s-D CT)

    International Nuclear Information System (INIS)

    Azia, A.; Hashmi, R.

    1999-01-01

    Cleft palate is a congenital anomaly with major development concerns. Surgery with bone grafting is often required to correct the lesion. With the introduction of 3-D CT the evaluation of cleft pa late has become more accurate. We present two cases of cleft palate, which were operated upon with bone grafting. We employed 3-D CT techniques in addition to the conventional 2-D CT, 3-D CT improves the estimation of the required bone graft and signification reduces length of surgery and complications. (author)

  15. Precision of three-dimensional CT-assisted model production in the maxillofacial area

    International Nuclear Information System (INIS)

    Solar, P.; Ulm, C.; Lill, W.; Imhof, H.; Watzek, G.; Blahout, R.; Gruber, H.; Matejka, M.

    1992-01-01

    Individual skull model fabrication was introduced into preoperative diagnostics in maxillofacial surgery in the mid-1980s. The aim of the present study was to collect information on the reproducibility of a skull model milled from hardened polyurethane foam. This model was based on the CT data of a real skull. Twenty comparative studies were carried out on both the model and the original skull, the model showing an average inaccuracy of 1.6 mm. The deviations ranged between 0.0 and 3.6 mm; the general trend favouring enlargements. The total deviation of the model as compared to the original skull was 1.8%. A convincing aspect of the model, which cannot be obtained by any other method, is its plasticity and the possibility of 3D orientation on a lifesize model. This new method is already used in preoperative planning of corrections of post-traumatic defects and craniofacial deformities as well as in tumour surgery. (orig.)

  16. Three dimensional dose distribution comparison of simple and complex acquisition trajectories in dedicated breast CT

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Jainil P., E-mail: jainil.shah@duke.edu [Department of Biomedical Engineering, Duke University, Durham, North Carolina 27705 and Multi Modality Imaging Lab, Duke University Medical Center, Durham, North Carolina 27710 (United States); Mann, Steve D. [Medical Physics Graduate Program, Duke University Medical Center, Durham, North Carolina 27705 and Multi Modality Imaging Lab, Duke University Medical Center, Durham, North Carolina 27710 (United States); McKinley, Randolph L. [ZumaTek, Inc., Research Triangle Park, North Carolina 27709 (United States); Tornai, Martin P. [Department of Biomedical Engineering, Duke University, Durham, North Carolina 27705 (United States); Medical Physics Graduate Program, Duke University Medical Center, Durham, North Carolina 27705 (United States); Multi Modality Imaging Lab, Duke University Medical Center, Durham, North Carolina 27710 (United States)

    2015-08-15

    Purpose: A novel breast CT system capable of arbitrary 3D trajectories has been developed to address cone beam sampling insufficiency as well as to image further into the patient’s chest wall. The purpose of this study was to characterize any trajectory-related differences in 3D x-ray dose distribution in a pendant target when imaged with different orbits. Methods: Two acquisition trajectories were evaluated: circular azimuthal (no-tilt) and sinusoidal (saddle) orbit with ±15° tilts around a pendant breast, using Monte Carlo simulations as well as physical measurements. Simulations were performed with tungsten (W) filtration of a W-anode source; the simulated source flux was normalized to the measured exposure of a W-anode source. A water-filled cylindrical phantom was divided into 1 cm{sup 3} voxels, and the cumulative energy deposited was tracked in each voxel. Energy deposited per voxel was converted to dose, yielding the 3D distributed dose volumes. Additionally, three cylindrical phantoms of different diameters (10, 12.5, and 15 cm) and an anthropomorphic breast phantom, initially filled with water (mimicking pure fibroglandular tissue) and then with a 75% methanol-25% water mixture (mimicking 50–50 fibroglandular-adipose tissues), were used to simulate the pendant breast geometry and scanned on the physical system. Ionization chamber calibrated radiochromic film was used to determine the dose delivered in a 2D plane through the center of the volume for a fully 3D CT scan using the different orbits. Results: Measured experimental results for the same exposure indicated that the mean dose measured throughout the central slice for different diameters ranged from 3.93 to 5.28 mGy, with the lowest average dose measured on the largest cylinder with water mimicking a homogeneously fibroglandular breast. These results align well with the cylinder phantom Monte Carlo studies which also showed a marginal difference in dose delivered by a saddle trajectory in the

  17. Three dimensional dose distribution comparison of simple and complex acquisition trajectories in dedicated breast CT

    International Nuclear Information System (INIS)

    Shah, Jainil P.; Mann, Steve D.; McKinley, Randolph L.; Tornai, Martin P.

    2015-01-01

    Purpose: A novel breast CT system capable of arbitrary 3D trajectories has been developed to address cone beam sampling insufficiency as well as to image further into the patient’s chest wall. The purpose of this study was to characterize any trajectory-related differences in 3D x-ray dose distribution in a pendant target when imaged with different orbits. Methods: Two acquisition trajectories were evaluated: circular azimuthal (no-tilt) and sinusoidal (saddle) orbit with ±15° tilts around a pendant breast, using Monte Carlo simulations as well as physical measurements. Simulations were performed with tungsten (W) filtration of a W-anode source; the simulated source flux was normalized to the measured exposure of a W-anode source. A water-filled cylindrical phantom was divided into 1 cm"3 voxels, and the cumulative energy deposited was tracked in each voxel. Energy deposited per voxel was converted to dose, yielding the 3D distributed dose volumes. Additionally, three cylindrical phantoms of different diameters (10, 12.5, and 15 cm) and an anthropomorphic breast phantom, initially filled with water (mimicking pure fibroglandular tissue) and then with a 75% methanol-25% water mixture (mimicking 50–50 fibroglandular-adipose tissues), were used to simulate the pendant breast geometry and scanned on the physical system. Ionization chamber calibrated radiochromic film was used to determine the dose delivered in a 2D plane through the center of the volume for a fully 3D CT scan using the different orbits. Results: Measured experimental results for the same exposure indicated that the mean dose measured throughout the central slice for different diameters ranged from 3.93 to 5.28 mGy, with the lowest average dose measured on the largest cylinder with water mimicking a homogeneously fibroglandular breast. These results align well with the cylinder phantom Monte Carlo studies which also showed a marginal difference in dose delivered by a saddle trajectory in the

  18. Anatomic variation of the clavicle: A novel three-dimensional study.

    LENUS (Irish Health Repository)

    Daruwalla, Zubin J

    2010-03-01

    An understanding of the complex anatomy of the clavicle is helpful in the treatment of clavicular fractures. Using three-dimensional (3D) statistical shape analysis, the author presents a novel method to assess geometric morphology of the clavicle. Fifteen fresh frozen shoulder specimens were scanned using high-resolution computerized tomography (CT) but four were excluded from the study. A further 16 high-resolution CT scans of the clavicle were obtained by searching the hospital database. All 27 scans were reconstructed and subsequently imported into and analyzed using a specifically developed statistical software package. Using statistical shape analysis, geometric parameters were then measured. Both gender as well as side specific geometric morphology were observed. Clavicles in men were longer, wider, and thicker than in women. Right clavicles had a greater medial depth than left clavicles, especially in women. Clavicles in men had a greater lateral depth than in women. The sternal angle in women was larger than in men. Using 3D statistical shape analysis and applying it to the clavicle standardizes the study of its anatomy, rules out any variability, and calculates morphological parameters that are accurate, precise, and reproducible. This unique approach provides information that is useful not only to the clinician but also in the modification of current or design of future clavicle fixation devices. More importantly, from an anatomy standpoint, implementation of this novel approach in anatomical studies would eliminate intra- and interobserver variation and allow all studies to be standardized and thus more comparable.

  19. Three dimensional morphological studies of Larger Benthic Foraminifera at the population level using micro computed tomography

    Science.gov (United States)

    Kinoshita, Shunichi; Eder, Wolfgang; Woeger, Julia; Hohenegger, Johann; Briguglio, Antonino; Ferrandez-Canadell, Carles

    2015-04-01

    Symbiont-bearing larger benthic Foraminifera (LBF) are long-living marine (at least 1 year), single-celled organisms with complex calcium carbonate shells. Their morphology has been intensively studied since the middle of the nineteenth century. This led to a broad spectrum of taxonomic results, important from biostratigraphy to ecology in shallow water tropical to warm temperate marine palaeo-environments. However, it was necessary for the traditional investigation methods to cut or destruct specimens for analysing the taxonomically important inner structures. X-ray micro-computed tomography (microCT) is one of the newest techniques used in morphological studies. The greatest advantage is the non-destructive acquisition of inner structures. Furthermore, the running improve of microCT scanners' hard- and software provides high resolution and short time scans well-suited for LBF. Three-dimensional imaging techniques allow to select and extract each chamber and to measure easily its volume, surface and several form parameters used for morphometric analyses. Thus, 3-dimensional visualisation of LBF-tests is a very big step forward from traditional morphology based on 2-dimensional data. The quantification of chamber form is a great opportunity to tackle LBF structures, architectures and the bauplan geometry. The micrometric digital resolution is the only way to solve many controversies in phylogeny and evolutionary trends of LBF. For the present study we used micro-computed tomography to easily investigate the chamber number of every specimen from statistically representative part of populations to estimate population dynamics. Samples of living individuals are collected at monthly intervals from fixed locations. Specific preparation allows to scan up to 35 specimens per scan within 2 hours and to obtain the complete digital dataset for each specimen of the population. MicroCT enables thus a fast and precise count of all chambers built by the foraminifer from its

  20. Dose response study of PVA-Fx gel for three dimensional dose distribution

    International Nuclear Information System (INIS)

    Brindha, S.; Ayyangar, Komanduri M.; Shen, Bin; Saw, Cheng B.

    2001-01-01

    Modern radiotherapy techniques involve complex field arrangements using conformal and intensity modulated radiation that requires three dimensional treatment planning. The verification of these plans poses even more challenge. In 1984, Gore et al., proposed that ferrous gel dosimeters combined with magnetic resonance imaging (MRI) could be used to measure three dimensional radiation dose distributions. Since then, there has been much interest in the development of gel dosimetry to aid the determination of three dimensional dose distributions during field arrangements. In this work, preparation and study of the MR characteristics of a PVA-Fx gel reported in the literature is presented

  1. Three-dimensional computed tomography reconstruction for operative planning in robotic segmentectomy: a pilot study.

    Science.gov (United States)

    Le Moal, Julien; Peillon, Christophe; Dacher, Jean-Nicolas; Baste, Jean-Marc

    2018-01-01

    The objective of our pilot study was to assess if three-dimensional (3D) reconstruction performed by Visible Patient™ could be helpful for the operative planning, efficiency and safety of robot-assisted segmentectomy. Between 2014 and 2015, 3D reconstructions were provided by the Visible Patient™ online service and used for the operative planning of robotic segmentectomy. To obtain 3D reconstruction, the surgeon uploaded the anonymized computed tomography (CT) image of the patient to the secured Visible Patient™ server and then downloaded the model after completion. Nine segmentectomies were performed between 2014 and 2015 using a pre-operative 3D model. All 3D reconstructions met our expectations: anatomical accuracy (bronchi, arteries, veins, tumor, and the thoracic wall with intercostal spaces), accurate delimitation of each segment in the lobe of interest, margin resection, free space rotation, portability (smartphone, tablet) and time saving technique. We have shown that operative planning by 3D CT using Visible Patient™ reconstruction is useful in our practice of robot-assisted segmentectomy. The main disadvantage is the high cost. Its impact on reducing complications and improving surgical efficiency is the object of an ongoing study.

  2. MATERIALS COMPATIBILITY STUDY FOR THREE-DIMENSIONAL PRINTER MATERIALS

    Science.gov (United States)

    2017-09-01

    shown that the nanoparticle vapor emitted by a 3D printer can present both environmental and health concerns. A study by the Built Environment...because of the different retention times and spectral features (Figures 10–13). In addition , azacyclotrodecan-2-one (62% confidence level for...to separate the PEG from the rest of the compounds to enhance the ionization. It is possible that in addition to applying a column, other types of

  3. Analysis of the sacrum: CT with two-dimensional and three-dimensional imaging

    International Nuclear Information System (INIS)

    Magid, D.; Fishman, E.K.; Scott, W.W. Jr.; Brooker, A.F. Jr.

    1987-01-01

    Fifteen patients with sacral lesions were assessed using CT and volumetric 3D image rendering. Lesions imaged included sacral fractures, tumors, osteomyelitis, dysplasia, and sacroiliac diastasis. In all cases, transaxial CT alone was superior to conventional radiographs, and CT with 3D was more clinically useful than CT alone. The 3D real-time video format allows rotation and manipulation in several planes, including the X (spinal) and Z (somersaulting) axes, for optimal visualization of abnormalities. The Z axis gives unique unimpeded inlet, outlet, and ''bird's-eye'' views of the pelvis and sacrum, enhancing detection and characterization of sacral of SI disruptions and subsequent pelvic ring compromise. Because of the ease of assimilating information in such a format, 3D may become the key modality for preoperative planning and for postoperative follow-up

  4. Three-dimensional dosimetry in brachytherapy: A MAGAT study

    Energy Technology Data Exchange (ETDEWEB)

    Lin, M.-H. [Department of Family Medicine and Physical Check-up Center, Tainan Hospital Department of Health, Executive Yuan, Taiwan (China); Department of Nursing, National Tainan Institute of Nursing, Taiwan (China); Huang, T.-C. [Department of Biomedical Imaging and Radiological Science, China Medical University, Taiwan (China); Kao, M.-J. [Department of Family Medicine and Physical Check-up Center, Tainan Hospital Department of Health, Executive Yuan, Taiwan (China); Department of Nursing, National Tainan Institute of Nursing, Taiwan (China); Wu, Jay [Department of Radiological Technology, Central Taiwan University of Science and Technology, Taiwan (China); Chen, C.-L. [Department of Medical Imaging and Radiological Sciences, Chung Shan Medical University, No. 110, Sec. 1, Chien-Kuo N. Road, South District, Taichung 402, Taiwan (China); Wu, T.-H. [Department of Medical Imaging and Radiological Sciences, Chung Shan Medical University, No. 110, Sec. 1, Chien-Kuo N. Road, South District, Taichung 402, Taiwan (China)], E-mail: tung@csmu.edu.tw

    2009-07-15

    This study is to evaluate the influence of using different matrix size of smoothing filter for image post-processing and various slice thickness during MR imaging on dose estimation in Ir-192 HDR brachytherapy via normoxic polymer gel dosimeter. Our results show its sensitive nature in gel dosimeter while changing these parameters, among which the combination of 2 mm slice thickness of MR images and [5x5] smoothing filter are considered the optimal parameters to provide accurate dose estimations and isodose curves.

  5. Three-dimensional dosimetry in brachytherapy: A MAGAT study

    International Nuclear Information System (INIS)

    Lin, M.-H.; Huang, T.-C.; Kao, M.-J.; Wu, Jay; Chen, C.-L.; Wu, T.-H.

    2009-01-01

    This study is to evaluate the influence of using different matrix size of smoothing filter for image post-processing and various slice thickness during MR imaging on dose estimation in Ir-192 HDR brachytherapy via normoxic polymer gel dosimeter. Our results show its sensitive nature in gel dosimeter while changing these parameters, among which the combination of 2 mm slice thickness of MR images and [5x5] smoothing filter are considered the optimal parameters to provide accurate dose estimations and isodose curves.

  6. A numerical study of three-dimensional droplets spreading on chemically patterned surfaces

    KAUST Repository

    Zhong, Hua; Wang, Xiao-Ping; Sun, Shuyu

    2016-01-01

    We study numerically the three-dimensional droplets spreading on physically flat chemically patterned surfaces with periodic squares separated by channels. Our model consists of the Navier-Stokes-Cahn-Hilliard equations with the generalized Navier

  7. Three-dimensional simulation study of compact toroid plasmoid injection into magnetized plasmas

    International Nuclear Information System (INIS)

    Suzuki, Y.; Watanabe, T.-H.; Sato, T.; Hayashi, T.

    1999-04-01

    Three-dimensional dynamics of a compact toroid (CT) plasmoid, which is injected into a magnetized target plasma region is investigated by using magnetohydrodynamic (MHD) numerical simulations. It is found that the process of the CT penetration into this region is much more complicated than what has been analyzed so far by using a conducting sphere (CS) model. The injected CT suffers from a tilting instability, which grows with the similar time scale as the CT penetration. The instability is accompanied by magnetic reconnection between the CT magnetic field and the target magnetic field, which disrupts the magnetic configuration of the CT. Magnetic reconnection plays a role to supply the high density plasma initially confined in the CT magnetic field into the target region. Also, the penetration depth of the CT high density plasma is examined. It is shown to be shorter than that estimated from the CS model. The CT high density plasma is decelerated mainly by the Lorentz force of the target magnetic field, which includes not only the magnetic pressure force but also the magnetic tension force. Furthermore, by comparing the CT plasmoid injection with the bare plasmoid injection, magnetic reconnection is considered to relax the magnetic tension force, that is the deceleration of the CT plasmoid. (author)

  8. Comparison of prostate positioning guided by three-dimensional transperineal ultrasound and cone beam CT

    Energy Technology Data Exchange (ETDEWEB)

    Li, Minglun; Ballhausen, Hendrik; Hegemann, Nina-Sophie; Reiner, Michael; Manapov, Farkhad; Corradini, Stefanie; Ganswindt, Ute; Belka, Claus [University Hospital Munich, LMU Munich, Department of Radiation Oncology, Munich (Germany); Tritschler, Stefan; Gratzke, Christian [University Hospital Munich, LMU Munich, Department of Urology, Munich (Germany)

    2017-03-15

    The accuracy of a transperineal three-dimensional ultrasound system (3DUS) was assessed for prostate positioning and compared to fiducial- and bone-based positioning in kV cone beam computed tomography (CBCT) during definitive radiotherapy of prostate cancer. Each of the 7 patients had three fiducial markers implanted into the prostate before treatment. Prostate positioning was simultaneously measured by 3DUS and CBCT before each fraction. In total, 177 pairs of 3DUS and CBCT scans were collected. Bone-match and seed-match were performed for each CBCT. Using seed-match as a reference, the accuracy of 3DUS and bone-match was evaluated. Systematic and random errors as well as optimal setup margins were calculated for 3DUS and bone-match. The discrepancy between 3DUS and seed-match in CBCT (average ± standard deviation) was 0.0 ± 1.7 mm laterally, 0.2 ± 2.0 mm longitudinally, and 0.3 ± 1.7 mm vertically. Using seed-match as a reference, systematic errors for 3DUS were 1.2 mm, 1.1 mm, and 0.9 mm; and random errors were 1.4 mm, 1.8 mm, and 1.6 mm, on lateral, longitudinal, and vertical axes, respectively. By analogy, the difference of bone-match to seed-match was 0.1 ± 1.1 mm laterally, 1.3 ± 3.8 mm longitudinally, and 1.3 ± 4.5 mm vertically. Systematic errors were 0.5 mm, 2.2 mm, and 2.6 mm; and random errors were 1.0 mm, 3.1 mm, and 3.9 mm on lateral, longitudinal, and vertical axes, respectively. The accuracy of 3DUS was significantly higher than that of bone-match on longitudinal and vertical axes, but not on the lateral axis. Image-guided radiotherapy of prostate cancer based on transperineal 3DUS was feasible, with overall small discrepancy to seed-match in CBCT in this retrospective study. Compared to bone-match, transperineal 3DUS achieved higher accuracy on longitudinal and vertical axes. (orig.) [German] Bewertung der Genauigkeit eines transperinealen dreidimensionalen Ultraschallsystems (3DUS) fuer die Prostatapositionierung und Vergleich mit

  9. TRIMARAN: a three dimensional multigroup P1 Monte Carlo code for criticality studies

    International Nuclear Information System (INIS)

    Ermumcu, G.; Gonnord, J.; Nimal, J.C.

    1980-01-01

    TRIMARAN is developed for safety analysis of nuclear components containing fissionable materials: shipping casks, storage and cooling pools, manufacture and reprocessing plants. It solves the transport equation by Monte Carlo method, in general three dimensional geometry with multigroup P1 approximation. A special representation of cross sections and numbers has been developed in order to reduce considerably the computing cost and allow this three dimensional code to compete with standard numerical program used in parametric studies

  10. TRIMARAN: a three dimensional multigroup P1 Monte Carlo code for criticallity studies

    International Nuclear Information System (INIS)

    Ermuncu, G.; Gonnord, J.; Nimal, J.C.

    1980-04-01

    TRIMARAN is developed for safety analysis of nuclar components containing fissionnable materials: shipping casks, storage and cooling pools, manufacture and reprocessing plants. It solves the transport equation by Monte Carlo method in general three dimensional geometry with multigroup P1 approximation. A special representation of cross sections and numbers has been developed in order to reduce considerably the computing cost and allow this three dimensional code to compete with standard numerical program used in parametric studies

  11. The helical three-dimensional CT in the diagnosis of torticollis with occipitocondylar hypoplasia

    International Nuclear Information System (INIS)

    Ilkko, E.; Tikkakoski, T.; Pyhtinen, J.

    1998-01-01

    Congenital anomalies of the atlanto-occipital and atlantoaxial joints are rare. Those most commonly reported are atlantoaxial instability, basilar impression, anomalies of the odontoid process, laxity of the transverse atlantal ligament and atlanto-occipital fusion. Occipital condylar hypoplasia is infrequent and difficult to recognise. We recently diagnosed it using helical 3D CT in association with torticollis in two patients. The first patient had a several year history of torticollis. The second patient had acute cervical lymphadenitis associated with post-operative torticollis. 3D CT distinctly revealed atlantoaxial subluxation with hypoplasia of the occipital condyles in both cases. (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  12. The helical three-dimensional CT in the diagnosis of torticollis with occipitocondylar hypoplasia

    International Nuclear Information System (INIS)

    Ilkko, E.; Tikkakoski, T.; Pyhtinen, J.

    1998-01-01

    Congenital anomalies of the atlanto-occipital and atlantoaxial joints are rare. Those most commonly reported are atlantoaxial instability, basilar impression, anomalies of the odontoid process, laxity of the transverse atlantal ligament and atlanto-occipital fusion. Occipital condylar hypoplasia is infrequent and difficult to recognise. We recently diagnosed it using helical 3D CT in association with torticollis in two patients. The first patient had a several year history of torticollis. The second patient had acute cervical lymphadenitis associated with post-operative torticollis. 3D CT distinctly revealed atlantoaxial subluxation with hypoplasia of the occipital condyles in both cases

  13. Real-time interactive three-dimensional display of CT and MR imaging volume data

    International Nuclear Information System (INIS)

    Yla-Jaaski, J.; Kubler, O.; Kikinis, R.

    1987-01-01

    Real-time reconstruction of surfaces from CT and MR imaging volume data is demonstrated using a new algorithm and implementation in a parallel computer system. The display algorithm accepts noncubic 16-bit voxels directly as input. Operations such as interpolation, classification by thresholding, depth coding, simple lighting effects, and removal of parts of the volume by clipping planes are all supported on-line. An eight-processor implementation of the algorithm renders surfaces from typical CT data sets in real time to allow interactive rotation of the volume

  14. Long term three dimensional tracking of orthodontic patients using registered cone beam CT and photogrammetry.

    Science.gov (United States)

    Boulanger, Pierre; Flores-Mir, Carlos; Ramirez, Juan F; Mesa, Elizabeth; Branch, John W

    2009-01-01

    The measurements from registered images obtained from Cone Beam Computed Tomography (CBCT) and a photogrammetric sensor are used to track three-dimensional shape variations of orthodontic patients before and after their treatments. The methodology consists of five main steps: (1) the patient's bone and skin shapes are measured in 3D using the fusion of images from a CBCT and a photogrammetric sensor. (2) The bone shape is extracted from the CBCT data using a standard marching cube algorithm. (3) The bone and skin shape measurements are registered using titanium targets located on the head of the patient. (4) Using a manual segmentation technique the head and lower jaw geometry are extracted separately to deal with jaw motion at the different record visits. (5) Using natural features of the upper head the two datasets are then registered with each other and then compared to evaluate bone, teeth, and skin displacements before and after treatments. This procedure is now used at the University of Alberta orthodontic clinic.

  15. Magnetohydrodynamic study of three-dimensional instability of the spontaneous fast magnetic reconnection

    International Nuclear Information System (INIS)

    Shimizu, T.; Kondoh, K.; Ugai, M.; Shibata, K.

    2009-01-01

    Three-dimensional instability of the spontaneous fast magnetic reconnection is studied with magnetohydrodynamic (MHD) simulation, where the two-dimensional model of the spontaneous fast magnetic reconnection is destabilized in three dimension. Generally, in two-dimensional magnetic reconnection models, every plasma condition is assumed to be uniform in the sheet current direction. In such two-dimensional MHD simulations, the current sheet destabilized by the initial resistive disturbance can be developed to fast magnetic reconnection by a current driven anomalous resistivity. In this paper, the initial resistive disturbance includes a small amount of fluctuations in the sheet current direction, i.e., along the magnetic neutral line. The other conditions are the same as that of previous two-dimensional MHD studies for fast magnetic reconnection. Accordingly, we may expect that approximately two-dimensional fast magnetic reconnection occurs in the MHD simulation. In fact, the fast magnetic reconnection activated on the first stage of the simulation is two dimensional. However, on the subsequent stages, it spontaneously becomes three dimensional and is strongly localized in the sheet current direction. The resulting three-dimensional fast magnetic reconnection intermittently ejects three-dimensional magnetic loops. Such intermittent ejections of the three-dimensional loops are similar to the intermittent downflows observed in the solar flares. The ejection of the three-dimensional loops seems to be random but, numerically and theoretically, it is shown that the aspect ratio of the ejected loops is limited under a criterion.

  16. Three-dimensional CT features of occipital squama normal anatomy, anatomic variations and fractures

    International Nuclear Information System (INIS)

    Liu Jungang; Li Xin; Wang Chunxiang; Zhang Lin; Guo Wanhua

    2013-01-01

    Objective: To evaluate 3D CT features of normal anatomy, anatomic variations and fractures of occipital squama. Methods: The 3D CT features on MIP, VR images were analyzed retrospectively in 589 pediatric cases. The normal anatomy, anatomic variations and fractures of occipital squama were observed respectively, and the differential diagnostic features including the individual location, appearance and extension were analyzed. Results: Four hundred and thirty-three patients (75.2%) showed normal anatomy, including 154 patients with adult occipital anatomical features, 279 patients with posterior intraoccipital synchondrosis, and 37 patients with Kerckring-supraoccipital synchondrosis. When cases with recent trauma history were excluded, 113 patients (19.1%) showed anatomic variants, including unpenetrating sutures and penetrating sutures. The former could be subdivided to Mendosal sutures in 23 cases, superior median fissures in 19 cases, and midline supraoccipital fissures in 4 cases, while the latter could be subdivided to the interparietal bone variations in 54 cases, wormian bones in 23 cases, and accessory bones in 7 cases. Two or more variations coexisted in 33 cases. The occipital squama fractures were shown in 34 cases (5.6%), including linear fractures in 27 cases, comminuted fractures in 3 cases, with depression fracture in one case, separation of cranial sutures in 3 cases, and other fractures associated with variants in 3 cases. The fractures were sharp, or jagged, without limitation of the occification. Conclusion: There are different 3D CT features of normal anatomy, anatomic variations and fractures of occipital squama in children, which are important for making the accurate diagnosis. (authors)

  17. Automatic three-dimensional rib centerline extraction from CT scans for enhanced visualization and anatomical context

    Science.gov (United States)

    Ramakrishnan, Sowmya; Alvino, Christopher; Grady, Leo; Kiraly, Atilla

    2011-03-01

    We present a complete automatic system to extract 3D centerlines of ribs from thoracic CT scans. Our rib centerline system determines the positional information for the rib cage consisting of extracted rib centerlines, spinal canal centerline, pairing and labeling of ribs. We show an application of this output to produce an enhanced visualization of the rib cage by the method of Kiraly et al., in which the ribs are digitally unfolded along their centerlines. The centerline extraction consists of three stages: (a) pre-trace processing for rib localization, (b) rib centerline tracing, and (c) post-trace processing to merge the rib traces. Then we classify ribs from non-ribs and determine anatomical rib labeling. Our novel centerline tracing technique uses the Random Walker algorithm to segment the structural boundary of the rib in successive 2D cross sections orthogonal to the longitudinal direction of the ribs. Then the rib centerline is progressively traced along the rib using a 3D Kalman filter. The rib centerline extraction framework was evaluated on 149 CT datasets with varying slice spacing, dose, and under a variety of reconstruction kernels. The results of the evaluation are presented. The extraction takes approximately 20 seconds on a modern radiology workstation and performs robustly even in the presence of partial volume effects or rib pathologies such as bone metastases or fractures, making the system suitable for assisting clinicians in expediting routine rib reading for oncology and trauma applications.

  18. Radiologic study of mandibular foramen of mandibular prognathism by three-dimensional computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Hun; Moon, Cheol Hyun; Im, Jeong Soo; Seo, Hwa Jeong [Graduate School of Public Health and Social Welfare, Gachon University of Medicine and Science, Incheon (Korea, Republic of)

    2010-06-15

    This study is aimed to evaluate the position of mandibular foramen of mandibular prognathism patients using 3-dimensional CT images in order to reduce the chance of an anesthetic failure of the mandibular nerve and to prevent the damage to the inferior alveolar nerve during the orthognathic surgery. The control group consist of 30 patients with class I occlusion. The experimental group consist of 44 patients with class III malocclusion. Three-dimensional computed tomography was used to evaluate the position of the mandibular foramina. The distance between mandibular plane and mandibular foramen, class I was 25.385 mm, class III was 23.628 mm. About the distance between occlusal plane and mandibular foramen, class I was 1.478 mm, class III was 5.144 mm. The distance between posterior border plan of mandibular ramus and mandibular foramen had not statistically significant. About the distance between sagittal plane of mandible and mandibular foramen did not also showed statistically significant. The result of this study could help the clinicians to apprehend more accurate anatomical locations of the foramina on the mandible with various facial skeletal types. Thereby to perform more accurate block anesthesia of the mandibular nerve and osteotomy with minimal nerve damage. In addition, this study could provide fundamental data for any related researches about the location of the mandibular foramina for other purposes.

  19. Radiologic study of mandibular foramen of mandibular prognathism by three-dimensional computed tomography

    International Nuclear Information System (INIS)

    Lee, Seung Hun; Moon, Cheol Hyun; Im, Jeong Soo; Seo, Hwa Jeong

    2010-01-01

    This study is aimed to evaluate the position of mandibular foramen of mandibular prognathism patients using 3-dimensional CT images in order to reduce the chance of an anesthetic failure of the mandibular nerve and to prevent the damage to the inferior alveolar nerve during the orthognathic surgery. The control group consist of 30 patients with class I occlusion. The experimental group consist of 44 patients with class III malocclusion. Three-dimensional computed tomography was used to evaluate the position of the mandibular foramina. The distance between mandibular plane and mandibular foramen, class I was 25.385 mm, class III was 23.628 mm. About the distance between occlusal plane and mandibular foramen, class I was 1.478 mm, class III was 5.144 mm. The distance between posterior border plan of mandibular ramus and mandibular foramen had not statistically significant. About the distance between sagittal plane of mandible and mandibular foramen did not also showed statistically significant. The result of this study could help the clinicians to apprehend more accurate anatomical locations of the foramina on the mandible with various facial skeletal types. Thereby to perform more accurate block anesthesia of the mandibular nerve and osteotomy with minimal nerve damage. In addition, this study could provide fundamental data for any related researches about the location of the mandibular foramina for other purposes.

  20. Helical CT for emergency patients with cerebrovascular diseases. Diagnosis of cerebral aneurysms with subarachnoid hemorrhage (SAH) by three-dimensional CT angiography (3D-CTA)

    International Nuclear Information System (INIS)

    Matsumoto, Masato; Satoh, Naoki; Kobayashi, Touru; Kodama, Namio; Nakano, Masayuki; Watanabe, Youichi; Fujii, Masayuki

    1996-01-01

    Recently, the usefulness of three-dimensional CT angiography (3D-CTA) using helical CT has been reported. Although 3D-CTA has been applied for neurosurgical diseases, especially for surgical planning, it has not done for emergency patients because of the long time required for image reconstruction and location of a helical CT scanner. We studied emergency patients with SAH, and compared the 3D-CTA with angiography and surgical findings, using TOSHIBA X vigor. Twenty-two patients with SAH were evaluated. The helical CT was performed for 55 seconds with a bolus injection of 90 ml non-ionic, iodinated contrast medium at a rate of 3 ml/sec with a delay of 20 sec. Angiography was carried out immediately after the helical CT. Eighteen of 22 cases were operated on urgently. We were able to create the 3D-CTA in about 7 minutes, and diagnose aneurysms by the 3D-CTA before angiography. The 3D-CTA was able to demonstrate 30 of 31 aneurysms including 9 unruptured aneurysms. An unruptured internal carotid-posterior communicating artery aneurysm 1.3 mm in diameter and associated with a ruptured aneurysm was not detected by either the 3D-CTA or angiography. On the other hand, an unruptured Acom aneurysm 0.8 mm in diameter and associated with a ruptured aneurysm could be detected by the: 3D-CTA, but not by angiography. The 3D-CTA gave us useful information concerning the anatomical relationship of the aneurysm, its neck and parent artery, and the surrounding branches. There were no complications or side effects associated with the helical CT scan. Although the 3D-CTA requires further development of visualization of small arteries less than 1 mm in diameter, such as perforating arteries, subtraction technique of bony structure, and a method for checking cervical arteries, it is useful for diagnosis of emergency patients with SAH and urgent operations. We believe that an operation might be performed by only the 3D-CTA without the angiography in the near future. (author)

  1. Helical CT for emergency patients with cerebrovascular diseases. Diagnosis of cerebral aneurysms with subarachnoid hemorrhage (SAH) by three-dimensional CT angiography (3D-CTA)

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Masato; Satoh, Naoki; Kobayashi, Touru; Kodama, Namio; Nakano, Masayuki; Watanabe, Youichi; Fujii, Masayuki [Fukushima Medical School (Japan)

    1996-05-01

    Recently, the usefulness of three-dimensional CT angiography (3D-CTA) using helical CT has been reported. Although 3D-CTA has been applied for neurosurgical diseases, especially for surgical planning, it has not done for emergency patients because of the long time required for image reconstruction and location of a helical CT scanner. We studied emergency patients with SAH, and compared the 3D-CTA with angiography and surgical findings, using TOSHIBA X vigor. Twenty-two patients with SAH were evaluated. The helical CT was performed for 55 seconds with a bolus injection of 90 ml non-ionic, iodinated contrast medium at a rate of 3 ml/sec with a delay of 20 sec. Angiography was carried out immediately after the helical CT. Eighteen of 22 cases were operated on urgently. We were able to create the 3D-CTA in about 7 minutes, and diagnose aneurysms by the 3D-CTA before angiography. The 3D-CTA was able to demonstrate 30 of 31 aneurysms including 9 unruptured aneurysms. An unruptured internal carotid-posterior communicating artery aneurysm 1.3 mm in diameter and associated with a ruptured aneurysm was not detected by either the 3D-CTA or angiography. On the other hand, an unruptured Acom aneurysm 0.8 mm in diameter and associated with a ruptured aneurysm could be detected by the: 3D-CTA, but not by angiography. The 3D-CTA gave us useful information concerning the anatomical relationship of the aneurysm, its neck and parent artery, and the surrounding branches. There were no complications or side effects associated with the helical CT scan. Although the 3D-CTA requires further development of visualization of small arteries less than 1 mm in diameter, such as perforating arteries, subtraction technique of bony structure, and a method for checking cervical arteries, it is useful for diagnosis of emergency patients with SAH and urgent operations. We believe that an operation might be performed by only the 3D-CTA without the angiography in the near future. (author)

  2. Automated extraction of pleural effusion in three-dimensional thoracic CT images

    Science.gov (United States)

    Kido, Shoji; Tsunomori, Akinori

    2009-02-01

    It is important for diagnosis of pulmonary diseases to measure volume of accumulating pleural effusion in threedimensional thoracic CT images quantitatively. However, automated extraction of pulmonary effusion correctly is difficult. Conventional extraction algorithm using a gray-level based threshold can not extract pleural effusion from thoracic wall or mediastinum correctly, because density of pleural effusion in CT images is similar to those of thoracic wall or mediastinum. So, we have developed an automated extraction method of pulmonary effusion by use of extracting lung area with pleural effusion. Our method used a template of lung obtained from a normal lung for segmentation of lungs with pleural effusions. Registration process consisted of two steps. First step was a global matching processing between normal and abnormal lungs of organs such as bronchi, bones (ribs, sternum and vertebrae) and upper surfaces of livers which were extracted using a region-growing algorithm. Second step was a local matching processing between normal and abnormal lungs which were deformed by the parameter obtained from the global matching processing. Finally, we segmented a lung with pleural effusion by use of the template which was deformed by two parameters obtained from the global matching processing and the local matching processing. We compared our method with a conventional extraction method using a gray-level based threshold and two published methods. The extraction rates of pleural effusions obtained from our method were much higher than those obtained from other methods. Automated extraction method of pulmonary effusion by use of extracting lung area with pleural effusion is promising for diagnosis of pulmonary diseases by providing quantitative volume of accumulating pleural effusion.

  3. Development of a three-dimensional PIV measurement technique for the experimental study of air bubble collapse phenomena

    International Nuclear Information System (INIS)

    Yang, Y.H.; Hassan, Y.A.; Schmidl, W.D.

    1995-01-01

    Particle image velocimetry (PIV) is a quantitative flow measurement technique. The objective of this study is to develop a new three-dimensional PIV technique for the experimental study of air bubble collapse phenomena. A three-dimensional measurement technique is necessary since bubble collapse is a three-dimensional phenomenon. The investigation of the velocity flow field around a collapsing air bubble can provide detailed three-dimensional quantitative information to help improve the understanding of the related heat transfer processes

  4. The usefulness of three-dimensional imaging with spiral CT in the evaluation of upper airway stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Won Ho; Yoon, Dae Young; Bae, Sang Hoon; Rho, Young Soo; Jung, Yin Gyo [Hallym Univ. College of Medicine, Seoul (Korea, Republic of)

    1996-01-01

    To assess the usefulness of three-dimensional (3D) spiral CT imaging in patients with upper airway stenosis. We performed 3D spiral CT imagings in ten patients in whom upper airway stenosis was clinically suspected. Eight of these patients had upper airway stenosis caused by intubation or tracheostomy (n-6), tuberculosis (n=1), or extrinsic compression by a thyroid mass (n=1). Spiral CT scanning (30-second continuous exposure and 90-mm length) was performed with a table speed of 3mm/sec and a section thickness of 3mm. The selected starting point was the epiglottis. The resulting data were reformatted by multiplanar reformation (MPR) and shaded surface display (SSD) with peeling after reconstruction of 2mm interval. In the evaluation of location and extent of stenosis, we compared fidings of 3D imaging with those of baseline axial images (n=10), endoscopy (n=9) and operation (n=4). The locations of stenosis in eight patients were as follows;tracheostoma (n=4), subglottic region (n=3), and larynx (n=1). In all eight, 3D imaging demonstrated the location and extent of stenosis, which exactly correlated with endoscopic and operative findings. In one patient, however, another stenotic area in the tracheal bifurcation was not discovered because this lesion was not included in the field of CT scan. In two patients, the diagnosis on 3D images of no 'stenosis' was comfirmed by clinical findings or operation. No differences in diagnostic accuracy were noted between axial images, MPR, and SSD when evalvating the location and extent of stenosis; vertical extent was shown more easily by 3D imaging than by axial images, however. 3D imaging with spiral CT may be an useful adjunctive method in the evaluation of upper airway stenosis with variable causes.

  5. The usefulness of three-dimensional imaging with spiral CT in the evaluation of upper airway stenosis

    International Nuclear Information System (INIS)

    Jang, Won Ho; Yoon, Dae Young; Bae, Sang Hoon; Rho, Young Soo; Jung, Yin Gyo

    1996-01-01

    To assess the usefulness of three-dimensional (3D) spiral CT imaging in patients with upper airway stenosis. We performed 3D spiral CT imagings in ten patients in whom upper airway stenosis was clinically suspected. Eight of these patients had upper airway stenosis caused by intubation or tracheostomy (n-6), tuberculosis (n=1), or extrinsic compression by a thyroid mass (n=1). Spiral CT scanning (30-second continuous exposure and 90-mm length) was performed with a table speed of 3mm/sec and a section thickness of 3mm. The selected starting point was the epiglottis. The resulting data were reformatted by multiplanar reformation (MPR) and shaded surface display (SSD) with peeling after reconstruction of 2mm interval. In the evaluation of location and extent of stenosis, we compared fidings of 3D imaging with those of baseline axial images (n=10), endoscopy (n=9) and operation (n=4). The locations of stenosis in eight patients were as follows;tracheostoma (n=4), subglottic region (n=3), and larynx (n=1). In all eight, 3D imaging demonstrated the location and extent of stenosis, which exactly correlated with endoscopic and operative findings. In one patient, however, another stenotic area in the tracheal bifurcation was not discovered because this lesion was not included in the field of CT scan. In two patients, the diagnosis on 3D images of no 'stenosis' was comfirmed by clinical findings or operation. No differences in diagnostic accuracy were noted between axial images, MPR, and SSD when evalvating the location and extent of stenosis; vertical extent was shown more easily by 3D imaging than by axial images, however. 3D imaging with spiral CT may be an useful adjunctive method in the evaluation of upper airway stenosis with variable causes

  6. SU-F-J-57: Effectiveness of Daily CT-Based Three-Dimensional Image Guided and Adaptive Proton Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Moriya, S [University of Tsukuba, Tsukuba, Ibaraki (Japan); National Cancer Center, Kashiwa, Chiba (Japan); Tachibana, H; Hotta, K; Baba, H; Kohno, R; Akimoto, T [National Cancer Center, Kashiwa, Chiba (Japan); Nakamura, N [National Cancer Center Hospital East, Kashiwa, Chiba (Japan); Miyakawa, S; Kurosawa, T [Komazawa University, Setagaya, Tokyo (Japan)

    2016-06-15

    Purpose: Daily CT-based three-dimensional image-guided and adaptive (CTIGRT-ART) proton therapy system was designed and developed. We also evaluated the effectiveness of the CTIGRT-ART. Methods: Retrospective analysis was performed in three lung cancer patients: Proton treatment planning was performed using CT image datasets acquired by Toshiba Aquilion ONE. Planning target volume and surrounding organs were contoured by a well-trained radiation oncologist. Dose distribution was optimized using 180-deg. and 270-deg. two fields in passive scattering proton therapy. Well commissioned Simplified Monte Carlo algorithm was used as dose calculation engine. Daily consecutive CT image datasets was acquired by an in-room CT (Toshiba Aquilion LB). In our in-house program, two image registrations for bone and tumor were performed to shift the isocenter using treatment CT image dataset. Subsequently, dose recalculation was performed after the shift of the isocenter. When the dose distribution after the tumor registration exhibits change of dosimetric parameter of CTV D90% compared to the initial plan, an additional process of was performed that the range shifter thickness was optimized. Dose distribution with CTV D90% for the bone registration, the tumor registration only and adaptive plan with the tumor registration was compared to the initial plan. Results: In the bone registration, tumor dose coverage was decreased by 16% on average (Maximum: 56%). The tumor registration shows better coverage than the bone registration, however the coverage was also decreased by 9% (Maximum: 22%) The adaptive plan shows similar dose coverage of the tumor (Average: 2%, Maximum: 7%). Conclusion: There is a high possibility that only image registration for bone and tumor may reduce tumor coverage. Thus, our proposed methodology of image guidance and adaptive planning using the range adaptation after tumor registration would be effective for proton therapy. This research is partially supported

  7. Three-dimensional whole-brain perfused blood volume imaging with multimodal CT for evaluation of acute ischaemic stroke

    International Nuclear Information System (INIS)

    Lu, J.; Zhang, M.; Cao, Y.; Ma, Q.; Chen, J.; Ji, X.; Li, K.

    2011-01-01

    Aim: To determine the diagnostic value of integrating three-dimensional perfused blood volume (3D PBV) with multimodal computed tomography (CT) [non-enhanced CT (NECT), CT perfusion (CTP), and CT angiography (CTA)] in acute ischaemic stroke. Materials and methods: NECT, CTP, and CTA were performed in 25 acute ischaemic stroke patients. The ischaemia detection rate of 3D PBV was compared with the results of baseline NECT and CTP. The correlation of ischaemic lesion volume between 3D PBV, CTP images, and follow-up NECT were analysed. Results: NECT demonstrated ischaemic signs in 12 of 25 patients with proven infarction. CTP maps of cerebral blood flow (CBF), cerebral blood volume (CBV), and time to peak (TTP) all demonstrated perfusion deficits in 21 of 25 patients. However, 3D PBV demonstrated perfusion deficits in all of the 25 patients. Among the 25 patients, a strong correlation was found between PBV and the follow-up NECT infarct (r = 0.858). The correlation between CTP and the follow-up NECT infarct as following: CBF (r = 0.718), CBV (r = 0.785), and TTP (r = 0.569). In 14 thrombolytic patients, strong correlation was found between the ischaemic volume on 3D PBV and follow-up NECT (r = 0.798). Conclusion: In acute stroke patients, the combination of 3D PBV and multimodal CT (NECT, CTP, and CTA) can improve the detection rate of ischaemia and enable assessment of the full extent of ischaemia, which correlates well with follow-up NECT.

  8. Preoperative Prediction of Ki-67 Labeling Index By Three-dimensional CT Image Parameters for Differential Diagnosis Of Ground-Glass Opacity (GGO.

    Directory of Open Access Journals (Sweden)

    Mingzheng Peng

    Full Text Available The aim of this study was to predict Ki-67 labeling index (LI preoperatively by three-dimensional (3D CT image parameters for pathologic assessment of GGO nodules. Diameter, total volume (TV, the maximum CT number (MAX, average CT number (AVG and standard deviation of CT number within the whole GGO nodule (STD were measured by 3D CT workstation. By detection of immunohistochemistry and Image Software Pro Plus 6.0, different Ki-67 LI were measured and statistically analyzed among preinvasive adenocarcinoma (PIA, minimally invasive adenocarcinoma (MIA and invasive adenocarcinoma (IAC. Receiver operating characteristic (ROC curve, Spearman correlation analysis and multiple linear regression analysis with cross-validation were performed to further research a quantitative correlation between Ki-67 labeling index and radiological parameters. Diameter, TV, MAX, AVG and STD increased along with PIA, MIA and IAC significantly and consecutively. In the multiple linear regression model by a stepwise way, we obtained an equation: prediction of Ki-67 LI=0.022*STD+0.001* TV+2.137 (R=0.595, R's square=0.354, p<0.001, which can predict Ki-67 LI as a proliferative marker preoperatively. Diameter, TV, MAX, AVG and STD could discriminate pathologic categories of GGO nodules significantly. Ki-67 LI of early lung adenocarcinoma presenting GGO can be predicted by radiologic parameters based on 3D CT for differential diagnosis.

  9. Quantification of pneumothorax volume on chest radiographs: comparison between the collins' and the axel's methods with three-dimensional CT as the standard of reference

    International Nuclear Information System (INIS)

    Lee, Chang Keun; Kim, Hyung Jin; Lee, Kyung Hee; Kim, Joung Taek; Kim, Kwang Ho; Suh, Chang Hae; Han, Heon

    1999-01-01

    The purpose of this study was twofold. In a preliminary study, we evaluated the accuracy of 3-D (three-dimensional) CT for the estimation of pneumothorax volume and for providing the optimal postprocessing method for clinical study. In the clinical study, we determined which of the two methods, Collins' and Axel's, was more accurate for the estimation of pneumothorax volume, as seen on chest radiographs, using 3-D CT as the standard of reference. In the preliminary study, 3-D CT was applied to phantoms and to four patients with pneumothorax using two different postprocessing methods, manual contour delineation and thresholding. In the clinical study, 3-D CT was performed in 13 patients with pneumothorax. For the purpose of evaluating conventional radiographs, a localizer scan was used for comparing the accuracy of Collins' method with that of Axel's method, with 3-D CT as the standard of reference. The preliminary study revealed that 3-D CT estimated pneumothorax volume with great accuracy and that manual contour delineation and thresholding measured volume equally well. Because of the shorter postprocessing time required with thresholding than with manual contour delineation (5 min versus 30 min), the former was used during clinical study. The results of this indicated close correlation between the measurements obtained using Collins' method on chest radiographs and those obtained by 3-D CT(r=0.95, p 0.05). 3-D CT can estimate pneumothorax volume with great accuracy. Collins' method is superior to Axel's method for the quantification of pneumothorax volume as seen on chest radiographs

  10. Study on design procedure of three-dimensional building base isolation system using thick rubber bearing

    International Nuclear Information System (INIS)

    Yabana, Shuichi; Matsuda, Akihiro

    2003-01-01

    In this study, design procedure on three-dimensional base isolation system is developed. Base isolation system proposed by CRIEPI uses thick rubber bearing and damper as isolation device. As for thick rubber bearings, design formula for evaluating vertical stiffness is proposed, and design conditions regarding size and vertical pressure are investigated. Figure-U type lead damper is proposed as three-dimensional damper and by loading tests its mechanical characteristics is evaluated. The concept of multi-layered interconnected rubber bearing, which is advantageous over large scale bearing in manufacturability, is proposed and its good performance is confirmed by the loading test. Through the response analyses, it is shown the rocking response of the proposed three-dimensional base isolation system is very small and not influential to the system, and the reduction of the vertical response is attained using the proposed isolation device. (author)

  11. Study of fission dynamics with the three-dimensional Langevin equations

    Energy Technology Data Exchange (ETDEWEB)

    Eslamizadeh, H. [Persian Gulf University, Department of Physics, Bushehr (Iran, Islamic Republic of)

    2011-11-15

    The dynamics of fission has been studied by solving one- and three-dimensional Langevin equations with dissipation generated through the chaos weighted wall and window friction formula. The average prescission neutron multiplicities, fission probabilities and the mean fission times have been calculated in a broad range of the excitation energy for compound nuclei {sup 210}Po and {sup 224}Th formed in the fusion-fission reactions {sup 4}He+{sup 206}Pb, {sup 16}O+{sup 208}Pb and results compared with the experimental data. The analysis of the results shows that the average prescission neutron multiplicities, fission probabilities and the mean fission times calculated by one- and three-dimensional Langevin equations are different from each other, and also the results obtained based on three-dimensional Langevin equations are in better agreement with the experimental data. (orig.)

  12. The accuracy of three-dimensional fused deposition modeling (FDM) compared with three-dimensional CT-Scans on the measurement of the mandibular ramus vertical length, gonion-menton length, and gonial angle

    Science.gov (United States)

    Savitri, I. T.; Badri, C.; Sulistyani, L. D.

    2017-08-01

    Presurgical treatment planning plays an important role in the reconstruction and correction of defects in the craniomaxillofacial region. The advance of solid freeform fabrication techniques has significantly improved the process of preparing a biomodel using computer-aided design and data from medical imaging. Many factors are implicated in the accuracy of the 3D model. To determine the accuracy of three-dimensional fused deposition modeling (FDM) models compared with three-dimensional CT scans in the measurement of the mandibular ramus vertical length, gonion-menton length, and gonial angle. Eight 3D models were produced from the CT scan data (DICOM file) of eight patients at the Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, University of Indonesia, Cipto Mangunkusumo Hospital. Three measurements were done three times by two examiners. The measurements of the 3D CT scans were made using OsiriX software, while the measurements of the 3D models were made using a digital caliper and goniometry. The measurement results were then compared. There is no significant difference between the measurements of the mandibular ramus vertical length, gonion-menton length, and gonial angle using 3D CT scans and FDM 3D models. FDM 3D models are considered accurate and are acceptable for clinical applications in dental and craniomaxillofacial surgery.

  13. Studying the Recent Improvements in Holograms for Three-Dimensional Display

    Directory of Open Access Journals (Sweden)

    Hamed Abbasi

    2014-01-01

    Full Text Available Displayers tend to become three-dimensional. The most advantage of holographic 3D displays is the possibility to observe 3D images without using glasses. The quality of created images by this method has surprised everyone. In this paper, the experimental steps of making a transmission hologram have been mentioned. In what follows, current advances of this science-art will be discussed. The aim of this paper is to study the recent improvements in creating three-dimensional images and videos by means of holographic techniques. In the last section we discuss the potentials of holography to be applied in future.

  14. Three-Dimensional Model Test Study of Xbloc Armoured Breakwaters at Punta Catalina, Dominican Republic

    DEFF Research Database (Denmark)

    Røge, Mads Sønderstrup; Andersen, Thomas Lykke

    The present report presents results from a three-dimensional model test study carried out at Aalborg University in the period June 2015 – August 2015. The objectives of the model tests were to study the stability of the Xbloc armoured breakwaters at Punta Catalina under short-crested wave attack...

  15. Extent of emphysema estimated by the three dimensional CT (3D-CT) predicts pulmonary dysfunction in patients with COPD

    International Nuclear Information System (INIS)

    Fujita, Etsuo; Inoue, Yoshikazu; Tanaka Isao

    2003-01-01

    We assessed the extent of emphysematous area by the 3D-CT in 35 chronic stable patients (age 66.5±8.9 yrs). And we evaluated the data from the total lung volume estimated by the 3D-CT, % low attenuation area below -950 HU (%LAA) and pulmonary function tests (PFT). Total lung volume estimated by 3D-CT was correlated with total lung capacity (TLC) by PFT (r=0.736, p<0.0005). The % LAA correlated with forced expiratory volume (FEV) 1% (r=-0.716, p<0.001). We concluded that the 3D-CT is the excellent method of evaluating the extent of emphysema without effort. (author)

  16. Two and three-dimensional morphometric analysis of trabecular bone using X-ray microtomography (μCT)

    International Nuclear Information System (INIS)

    Silva, Alessandro Marcio Hakme da; Silva, Orivaldo Lopes da; Silva Junior, Nelson Ferreira da; Alves, Jose Marcos

    2014-01-01

    Introduction: trabecular bones have a porous microstructure and can be modeled as linear elastic solids, heterogeneous and anisotropic. In the literature, few investigations have compared the two- dimensional (2D) and three-dimensional (3D) morphometric analyses of cancellous bone. Methods: In this investigation eighteen cylindrical samples of cancellous bone (10 mm of diameter and 20 mm of height) were obtained from six bovine head femurs, with similar values for the weight and age, of the same race and gender. The samples were harvested and freeze at - 20 °C before carrying out the micro CT analysis. The CT-Analyzer software was used to measure in three directions (superior-inferior, lateral-medial and anterior-posterior) parameters such as trabecular thickness, trabecular separation, trabecular number and the eigenvalues of the fabric tensor (M). Results: the Comparison of 2D and 3D analyses for the parameters: 2D (plate model) trabecular thickness, trabecular separation and trabecular number were statistically different (p = 0) showing that measurements are not similar to the 3D ones. However, 2D (rod model) trabecular thickness and 3D trabecular thickness measurements presented no significant difference (p = 0.26). The eigenvalues show that the bovine trabecular microstructure has a tendency to transversally isotropic symmetry. Discussion: The method proved to be quite interesting for the characterization of the bone structure through 3D measurements of trabecular bone morphometric parameters in the three possible directions of loading. The results show that x-ray microtomography (μCT) is a technique of great potential for characterization and generating bone quality parameters for the diagnosis of bone metabolism diseases. (author)

  17. Two and three-dimensional morphometric analysis of trabecular bone using X-ray microtomography (μCT)

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Alessandro Marcio Hakme da; Silva, Orivaldo Lopes da; Silva Junior, Nelson Ferreira da, E-mail: alhakme@sc.usp.br [Universidade de Sao Paulo (EESC/FMRP/IQSC/USP), Sao Carlos, SP (Brazil); Alves, Jose Marcos [Universidade de Sao Paulo (USP), Sao Carlos, SP (Brazil). Escola de Engenharia. Departamento de Engenharia Eletrica e Computacao

    2014-07-01

    Introduction: trabecular bones have a porous microstructure and can be modeled as linear elastic solids, heterogeneous and anisotropic. In the literature, few investigations have compared the two- dimensional (2D) and three-dimensional (3D) morphometric analyses of cancellous bone. Methods: In this investigation eighteen cylindrical samples of cancellous bone (10 mm of diameter and 20 mm of height) were obtained from six bovine head femurs, with similar values for the weight and age, of the same race and gender. The samples were harvested and freeze at - 20 °C before carrying out the micro CT analysis. The CT-Analyzer software was used to measure in three directions (superior-inferior, lateral-medial and anterior-posterior) parameters such as trabecular thickness, trabecular separation, trabecular number and the eigenvalues of the fabric tensor (M). Results: the Comparison of 2D and 3D analyses for the parameters: 2D (plate model) trabecular thickness, trabecular separation and trabecular number were statistically different (p = 0) showing that measurements are not similar to the 3D ones. However, 2D (rod model) trabecular thickness and 3D trabecular thickness measurements presented no significant difference (p = 0.26). The eigenvalues show that the bovine trabecular microstructure has a tendency to transversally isotropic symmetry. Discussion: The method proved to be quite interesting for the characterization of the bone structure through 3D measurements of trabecular bone morphometric parameters in the three possible directions of loading. The results show that x-ray microtomography (μCT) is a technique of great potential for characterization and generating bone quality parameters for the diagnosis of bone metabolism diseases. (author)

  18. Three-dimensional in vivo imaging of the murine liver: a micro-computed tomography-based anatomical study.

    Directory of Open Access Journals (Sweden)

    Teresa Fiebig

    Full Text Available Various murine models are currently used to study acute and chronic pathological processes of the liver, and the efficacy of novel therapeutic regimens. The increasing availability of high-resolution small animal imaging modalities presents researchers with the opportunity to precisely identify and describe pathological processes of the liver. To meet the demands, the objective of this study was to provide a three-dimensional illustration of the macroscopic anatomical location of the murine liver lobes and hepatic vessels using small animal imaging modalities. We analysed micro-CT images of the murine liver by integrating additional information from the published literature to develop comprehensive illustrations of the macroscopic anatomical features of the murine liver and hepatic vasculature. As a result, we provide updated three-dimensional illustrations of the macroscopic anatomy of the murine liver and hepatic vessels using micro-CT. The information presented here provides researchers working in the field of experimental liver disease with a comprehensive, easily accessable overview of the macroscopic anatomy of the murine liver.

  19. Usefulness of three-dimensional CT pancreatography (3D-CTP) after the balloon-ERP for pancreatic diseases

    International Nuclear Information System (INIS)

    Ueki, Toshiharu; Oishi, Yayoi; Sakaguchi, Seigo; Sakurai, Toshihiro; Yao, Tsuneyoshi; Ichimaru, Yoshihiko; Koga, Yuki; Ikeda, Seiyo

    1998-01-01

    The clinical usefulness of 3D-CTP combined with the balloon-ERP and helical-CT was discussed. Authors diagnosed 42 patients with pancreatic diseases, including 5 of pancreatic carcinoma, 3 of serous cystadenoma, 6 of muciparous pancreatic cyst, 28 of chronic pancreatitis (including 8 cases of complicated pseudocyst). The images could reconstruct three-dimensionally the tapering constriction in the main pancreatic duct for all 5 cases of pancreatic carcinoma, the exclusion in the main pancreatic duct for 3 cases of serous cystadenoma and 1 case of muciparous pancreatic cyst, the parietal irregularity for 14 cases and the smooth constriction for 9 cases in main pancreatic duct of chronic pancreatitis, the morphology of the cyst and the spatial relationship between the cyst and the pancreatic duct in 5 of 6 cases of muciparous pancreatic cyst and 7 of 8 cases of complicated pseudocyst. Furthermore, the 3D-CTP could demonstrate the branched pancreatic duct at the constriction site which was not detected by the balloon-ERP in 2 cases of chronic pancreatitis with the constriction at the main pancreatic duct, and the joining manner of cyst to the pancreatic duct which was indistinct by the balloon-ERP in 6 cases of pancreatic cyst. These results show that 3D-CTP is useful for the qualitative diagnosis and applicable for the understanding of pancreatic diseases and for the simulation of surgery. (K.H.)

  20. Dosimetry study on the conventional and three dimensional conformal radiation treatment planning protocols for rectal cancer

    International Nuclear Information System (INIS)

    Cai Yong; He Yuxiang; Han Shukui; Wu Hao; Gong Jian; Xu Bo

    2007-01-01

    Objective: To compare the dose distribution of clinical target volume (CTV), in normal tissues and organs for patients with rectal cancer on the conventional radiotherapy (2D) and three dimension- al conformal radiation treatment (3DCRT). Methods: The CT image data of 36 rectal cancer patients treated with 3DCRT were studied. The CTV, small bowel, colon, bladder, pelvic bone marrow, and femoral head and neck were contoured on consecutive axial slices of CT images. Two 3DCRT and three conventional treatment planning protocols were simulated using three dimensional treatment planning system (CMS Focus 2.31), were defined as 3D-3, 3D-4, 2D-2, 2D-3, 2D-4. The difference of five treatment planning protocols on the CTV and normal structure by analysis of dose-volume histograms (DVHs) were compared. Results: The D 95 and V 95 of these five protocols all exceeded 97%. The conformity index(CI) of 3D was obviously larger than that of 2D protocol. The dose inhomogeneity(DI) in 4 DCRT was less than that of 3 DCRT. The 3D as compared with the 2D, significantly reduced the mean dose of 45 Gy to the small bowel and colon. The 3D-3 as compared with the 2D-3, the 3D-4 as compared with the 2D-4, the mean dose of small bowel and colon was reduced by 28.5% and 25.7%, respectively. The 3D-3 as compared with the 2D-2, the 3D-3 as compared with the 2D-3 and the 3D4 as compared with the 2D-4, the percentage volume of small bowel and colon which received 45 Gy was reduced by 80.8% , 51.1% and 54.7% , respectively. Either the mean dose, or the percentage volume receiving 35 Gy and 45 Gy to the pelvic bone and bladder, the 3D planning protocols had advanage over the 2D planning protocols. The V 45 of bladder in 2D-2 planning proto- col was the highest in all planning protocols, exceeding 98%, but the highest V 45 of bladder was only 50% in the other planning protocols. Conclusions: Even though the difference in pelvic CTV of rectal cancer patients between the conventional radiotherapy and 3

  1. Primitive experience of three dimensional multi-slice spiral CT angiography for the follow-up of intracranial aneurysm clipping

    International Nuclear Information System (INIS)

    Yang Yunjun; Chen Weijian; Hu Zhangyong; Wu Enfu; Wang Meihao; Zhuge Qichuan; Zhongming; Cheng Jingliang; Ren Cuiping; Zhang Yong

    2008-01-01

    Objective To evaluate multi-slice three-dimensional CT angiography (MS 3D-CTA) for the follow-up of intracranial aneurysm clipping. Methods: MS 3D-CTA of 16 patients with intracranial aneurysm clipping were retrospectively analyzed. The patients were scanned on a 16-slice spiral CT (GE Lightspeed pro). Volume rendering(VR), thin maximum intensity projection(thin MIP) and multi-planar reconstruction (MPR) were employed in image postprocessing in all cases. Results: There were 17 clips in the 16 patients with aneurysm clipping. Six clips were located at the posterior communicating artery, 5 at the anterior communicating artery, 4 at the middle cerebral artery, and the remaining 2 clips were located at the pericallosal artery, in 1 patient. There were no abnormalities found in the aneurysm clipping region in 7 cases by MS 3D- CTA. There were residual aneurysm in 2 cases, parent artery stenosis in 4 cases, and artery spasm in 3 eases. There was no parent artery occlusion and clip displacement in all cases. VR showed excellent 3D spacial relations between the clip and parent artery in 12 cases, and showed good relations in 3 cases. The 1 case with 2 clips in the pericallosal artery showed heavy beam-hardening artifacts. The size and shape of aneurysm clips were clearly depicted by MPR and thin MIP, while 3D spacial relation of aneurysm clip and parent artery were poorly showed. Conclusion: MS 3D-CTA is a safe and efficient method for the follow-up of intracranialaneurysm clipping. Combined VR with MPR or thin MIP can well reveal postoperative changes after aneurysm clipping. (authors)

  2. Three-dimensional imaging modalities in endodontics

    Science.gov (United States)

    Mao, Teresa

    2014-01-01

    Recent research in endodontics has highlighted the need for three-dimensional imaging in the clinical arena as well as in research. Three-dimensional imaging using computed tomography (CT) has been used in endodontics over the past decade. Three types of CT scans have been studied in endodontics, namely cone-beam CT, spiral CT, and peripheral quantitative CT. Contemporary endodontics places an emphasis on the use of cone-beam CT for an accurate diagnosis of parameters that cannot be visualized on a two-dimensional image. This review discusses the role of CT in endodontics, pertaining to its importance in the diagnosis of root canal anatomy, detection of peri-radicular lesions, diagnosis of trauma and resorption, presurgical assessment, and evaluation of the treatment outcome. PMID:25279337

  3. Three-dimensional imaging modalities in endodontics

    Energy Technology Data Exchange (ETDEWEB)

    Mao, Teresa; Neelakantan, Prasanna [Dept. of Conservative Dentistry and Endodontics, Saveetha Dental College and Hospitals, Saveetha University, Chennai (India)

    2014-09-15

    Recent research in endodontics has highlighted the need for three-dimensional imaging in the clinical arena as well as in research. Three-dimensional imaging using computed tomography (CT) has been used in endodontics over the past decade. Three types of CT scans have been studied in endodontics, namely cone-beam CT, spiral CT, and peripheral quantitative CT. Contemporary endodontics places an emphasis on the use of cone-beam CT for an accurate diagnosis of parameters that cannot be visualized on a two-dimensional image. This review discusses the role of CT in endodontics, pertaining to its importance in the diagnosis of root canal anatomy, detection of peri-radicular lesions, diagnosis of trauma and resorption, presurgical assessment, and evaluation of the treatment outcome.

  4. Three-dimensional imaging modalities in endodontics

    International Nuclear Information System (INIS)

    Mao, Teresa; Neelakantan, Prasanna

    2014-01-01

    Recent research in endodontics has highlighted the need for three-dimensional imaging in the clinical arena as well as in research. Three-dimensional imaging using computed tomography (CT) has been used in endodontics over the past decade. Three types of CT scans have been studied in endodontics, namely cone-beam CT, spiral CT, and peripheral quantitative CT. Contemporary endodontics places an emphasis on the use of cone-beam CT for an accurate diagnosis of parameters that cannot be visualized on a two-dimensional image. This review discusses the role of CT in endodontics, pertaining to its importance in the diagnosis of root canal anatomy, detection of peri-radicular lesions, diagnosis of trauma and resorption, presurgical assessment, and evaluation of the treatment outcome

  5. Structural study of disordered SiC nanowires by three-dimensional rotation electron diffraction

    International Nuclear Information System (INIS)

    Li, Duan; Guo, Peng; Wan, Wei; Zou, Ji; Shen, Zhijian; Guzi de Moraes, Elisângela; Colombo, Paolo

    2014-01-01

    The structure of disordered SiC nanowires was studied by using the three-dimensional rotation electron diffraction (RED) technique. The streaks shown in the RED images indicated the stacking faults of the nanowire. High-resolution transmission electron microscopy imaging was employed to support the results from the RED data. It suggested that a 2H polytype is most possible for the nanowires. (paper)

  6. A study on three dimensional layout design by the simulated annealing method

    International Nuclear Information System (INIS)

    Jang, Seung Ho

    2008-01-01

    Modern engineered products are becoming increasingly complicated and most consumers prefer compact designs. Layout design plays an important role in many engineered products. The objective of this study is to suggest a method to apply the simulated annealing method to the arbitrarily shaped three-dimensional component layout design problem. The suggested method not only optimizes the packing density but also satisfies constraint conditions among the components. The algorithm and its implementation as suggested in this paper are extendable to other research objectives

  7. Validation of an enhanced knowledge-based method for segmentation and quantitative analysis of intrathoracic airway trees from three-dimensional CT images

    International Nuclear Information System (INIS)

    Sonka, M.; Park, W.; Hoffman, E.A.

    1995-01-01

    Accurate assessment of airway physiology, evaluated in terms of geometric changes, is critically dependent upon the accurate imaging and image segmentation of the three-dimensional airway tree structure. The authors have previously reported a knowledge-based method for three-dimensional airway tree segmentation from high resolution CT (HRCT) images. Here, they report a substantially improved version of the method. In the current implementation, the method consists of several stages. First, the lung borders are automatically determined in the three-dimensional set of HRCT data. The primary airway tree is semi-automatically identified. In the next stage, potential airways are determined in individual CT slices using a rule-based system that uses contextual information and a priori knowledge about pulmonary anatomy. Using three-dimensional connectivity properties of the pulmonary airway tree, the three-dimensional tree is constructed from the set of adjacent slices. The method's performance and accuracy were assessed in five 3D HRCT canine images. Computer-identified airways matched 226/258 observer-defined airways (87.6%); the computer method failed to detect the airways in the remaining 32 locations. By visual assessment of rendered airway trees, the experienced observers judged the computer-detected airway trees as highly realistic

  8. Three-dimensional study of flow past a square cylinder at low Reynolds numbers

    International Nuclear Information System (INIS)

    Saha, A.K.; Biswas, G.; Muralidhar, K.

    2003-01-01

    The spatial evolution of vortices and transition to three-dimensionality in the wake of a square cylinder have been numerically studied. A Reynolds number range between 150 and 500 has been considered. Starting from the two-dimensional Karman vortex street, the transition to three-dimensionality is found to take place at a Reynolds number between 150 and 175. The three-dimensional wake of the square cylinder has been characterized using indicators appropriate for the wake of a bluff body as described by the earlier workers. In these terms, the secondary vortices of Mode-A are seen to persist over the Reynolds number range of 175-240. At about a Reynolds number of 250, Mode-B secondary vortices are present, these having predominantly small-scale structures. The transitional flow around a square cylinder exhibits an intermittent low frequency modulation due to the formation of a large-scale irregularity in the near-wake, called vortex dislocation. The superposition of vortex dislocation and the Mode-A vortices leads to a new pattern, labelled as Mode-A with dislocations. The results for the square cylinder are in good accordance with the three-dimensional modes of transition that are well-known in the circular cylinder wake. In the case of a circular cylinder, the transition from periodic vortex shedding to Mode-A is characterized by a discontinuity in the Strouhal number-Reynolds number relationship at about a Reynolds of 190. The transition from Mode-A to Mode-B is characterized by a second discontinuity in the frequency law at a Reynolds number of ∼250. The numerical computations of the present study with a square cylinder show that the values of the Strouhal number and the time-averaged drag-coefficient are closely associated with each other over the range of Reynolds numbers of interest and reflect the spatial structure of the wake

  9. A Three-Dimensional Kinematic and Kinetic Study of the College-Level Female Softball Swing

    Science.gov (United States)

    Milanovich, Monica; Nesbit, Steven M.

    2014-01-01

    This paper quantifies and discusses the three-dimensional kinematic and kinetic characteristics of the female softball swing as performed by fourteen female collegiate amateur subjects. The analyses were performed using a three-dimensional computer model. The model was driven kinematically from subject swings data that were recorded with a multi-camera motion analysis system. Each subject used two distinct bats with significantly different inertial properties. Model output included bat trajectories, subject/bat interaction forces and torques, work, and power. These data formed the basis for a detailed analysis and description of fundamental swing kinematic and kinetic quantities. The analyses revealed that the softball swing is a highly coordinated and individual three-dimensional motion and subject-to-subject variations were significant in all kinematic and kinetic quantities. In addition, the potential effects of bat properties on swing mechanics are discussed. The paths of the hands and the centre-of-curvature of the bat relative to the horizontal plane appear to be important trajectory characteristics of the swing. Descriptions of the swing mechanics and practical implications are offered based upon these findings. Key Points The female softball swing is a highly coordinated and individual three-dimensional motion and subject-to-subject variations were significant in all kinematic and kinetic quantities. The paths of the grip point, bat centre-of-curvature, CG, and COP are complex yet reveal consistent patterns among subjects indicating that these patterns are fundamental components of the swing. The most important mechanical quantity relative to generating bat speed is the total work applied to the bat from the batter. Computer modeling of the softball swing is a viable means for study of the fundamental mechanics of the swing motion, the interactions between the batter and the bat, and the energy transfers between the two. PMID:24570623

  10. CT liver volumetry using three-dimensional image data in living donor liver transplantation: Effects of slice thickness on volume calculation

    Science.gov (United States)

    Hori, Masatoshi; Suzuki, Kenji; Epstein, Mark L.; Baron, Richard L.

    2011-01-01

    The purpose was to evaluate a relationship between slice thickness and calculated volume on CT liver volumetry by comparing the results for images with various slice thicknesses including three-dimensional images. Twenty adult potential liver donors (12 men, 8 women; mean age, 39 years; range, 24–64) underwent CT with a 64-section multi-detector row CT scanner after intra-venous injection of contrast material. Four image sets with slice thicknesses of 0.625 mm, 2.5 mm, 5 mm, and 10 mm were used. First, a program developed in our laboratory for automated liver extraction was applied to CT images, and the liver boundary was obtained automatically. Then, an abdominal radiologist reviewed all images on which automatically extracted boundaries were superimposed, and edited the boundary on each slice to enhance the accuracy. Liver volumes were determined by counting of the voxels within the liver boundary. Mean whole liver volumes estimated with CT were 1322.5 cm3 on 0.625-mm, 1313.3 cm3 on 2.5-mm, 1310.3 cm3 on 5-mm, and 1268.2 cm3 on 10-mm images. Volumes calculated for three-dimensional (0.625-mm-thick) images were significantly larger than those for thicker images (Pvolumetry. If not, three-dimensional images could be essential. PMID:21850689

  11. Study of the nonlinear three-dimensional Debye screening in plasmas

    International Nuclear Information System (INIS)

    Lin Chang; Zhao Jinbao; Zhang Xiulian

    2000-01-01

    The nonlinear three-dimensional Debye screening in plasmas is investigated. New analytical solutions for the three-dimensional Poisson equation have been obtained for the nonlinear Debye potential for the first time. We derive exact analytical expression for the special case of the nonlinear three-dimensional Debye screening in plasmas. (orig.)

  12. Three-dimensional growth simulation: A study of substrate oriented films

    International Nuclear Information System (INIS)

    Besnard, A; Martin, N; Carpentier, L

    2010-01-01

    Monte Carlo simulations are developed to simulate the growth of three-dimensional columnar microstructure in thin films. We are studying in particular oriented microstructure like those produced with the Glancing Angle Deposition technique (GLAD). Some geometrical characteristics of the particles flux, the organization of defect sites on the substrate surface and the atomic surface diffusion are mainly investigated in order to predict the growth processes and the resulting features of the films. This study reports on simulations of thin film growth exhibiting an oblique and zigzag columnar microstructure. Column angle evolution and density are investigated versus incidence angle α or period number n and compared with experimental measurements.

  13. [Study on sweat gland regeneration induced by microenvironment of three-dimensional bioprinting].

    Science.gov (United States)

    Yao, B; Xie, J F; Huang, S; Fu, X B

    2017-01-20

    Sweat glands are abundant in the body surface and essential for thermoregulation. Sweat glands fail to conduct self-repair in patients with large area of burn and trauma, and the body temperature of patients increases in hot climate, which may cause shock or even death. Now, co-culture system, reprogramming, and tissue engineering have made progresses in inducing sweat gland regeneration, but the inductive efficiency and duration need to be improved. Cellular microenvironment can regulate cell biological behavior, including cell migration and cell differentiation. This article reviews the studies of establishment of microenvironment in vitro by three-dimensional bioprinting technology to induce sweat gland regeneration.

  14. Alveolar Ridge Augmentation with Three-Dimensional Printed Hydroxyapatite Devices: A Preclinical Study.

    Science.gov (United States)

    Fiorellini, Joseph P; Norton, Michael R; Luan, Kevin WanXin; Kim, David Minjoon; Wada, Kei; Sarmiento, Hector L

    2018-02-14

    The objective of this study was to evaluate the effectiveness of precise three-dimensional hydroxyapatite printed micro- and macrochannel devices for alveolar ridge augmentation in a canine model. All grafts induced minimal inflammatory and fibrotic reactions. Examination of undecalcified sections revealed that both types of grafts demonstrated bone ingrowth. The majority of the bone growth into the block graft was into the channels, though a portion grew directly into the construct in the form of small bony spicules. In conclusion, bone ingrowth was readily demonstrated in the middle of the implanted printed devices.

  15. Three-dimensional Reconstruction Method Study Based on Interferometric Circular SAR

    Directory of Open Access Journals (Sweden)

    Hou Liying

    2016-10-01

    Full Text Available Circular Synthetic Aperture Radar (CSAR can acquire targets’ scattering information in all directions by a 360° observation, but a single-track CSAR cannot efficiently obtain height scattering information for a strong directive scatter. In this study, we examine the typical target of the three-dimensional circular SAR interferometry theoryand validate the theory in a darkroom experiment. We present a 3D reconstruction of the actual tank metal model of interferometric CSAR for the first time, verify the validity of the method, and demonstrate the important potential applications of combining 3D reconstruction with omnidirectional observation.

  16. Phase behaviour of heteronuclear dimers in three-dimensional systems-a Monte Carlo study

    International Nuclear Information System (INIS)

    Rzysko, W; Binder, K

    2008-01-01

    Monte Carlo simulation in the grand canonical ensemble, the histogram reweighting technique and finite size scaling are used to study the phase behaviour of dimers in three-dimensional systems. A single molecule is composed of two segments A and B, and the bond between them cannot be broken. The phase diagrams have been estimated for a set of model systems. Different structures formed by heteronuclear dimers have been found. The results show a great variety of vapour-liquid coexistence behaviour depending on the strength of the interactions between segments

  17. A comparative study of the deviation of the menton on posteroanterior cephalograms and three dimensional computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hee Jin; Lee, Sun Gene; Lee, Eun Joo; Kang, Byung Cheol; Lee, Jae Seo; Lim, Hoi Jeong; Yoon, Suk Ja [School of Dentistry, Dental Science Research Institute, Chonnam National University, Gwangju (Korea, Republic of); Song, In Ja [Dept. of Nursing, Kwangju Women' s University, Gwangju (Korea, Republic of)

    2016-03-15

    Facial asymmetry has been measured by the severity of deviation of the menton (Me) on posteroanterior (PA) cephalograms and three-dimensional (3D) computed tomography (CT). This study aimed to compare PA cephalograms and 3D CT regarding the severity of Me deviation and the direction of the Me. PA cephalograms and 3D CT images of 35 patients who underwent orthognathic surgery (19 males and 16 females, with an average age of 22.1±3.3 years) were retrospectively reviewed in this study. By measuring the distance and direction of the Me from the midfacial reference line and the midsagittal plane in the cephalograms and 3D CT, respectively, the x-coordinates (x1 and x2) of the Me were obtained in each image. The difference between the x-coordinates was calculated and statistical analysis was performed to compare the severity of Me deviation and the direction of the Me in the two imaging modalities. A statistically significant difference in the severity of Me deviation was found between the two imaging modalities (Δx=2.45±2.03 mm, p<0.05) using the one-sample t-test. Statistically significant agreement was observed in the presence of deviation (k=0.64, p<0.05) and in the severity of Me deviation (k=0.27, p<0.05). A difference in the direction of the Me was detected in three patients (8.6%). The severity of the Me deviation was found to vary according to the imaging modality in 16 patients (45.7%). The measurement of Me deviation may be different between PA cephalograms and 3D CT in some patients.

  18. A comparative study of the deviation of the menton on posteroanterior cephalograms and three dimensional computed tomography

    International Nuclear Information System (INIS)

    Lee, Hee Jin; Lee, Sun Gene; Lee, Eun Joo; Kang, Byung Cheol; Lee, Jae Seo; Lim, Hoi Jeong; Yoon, Suk Ja; Song, In Ja

    2016-01-01

    Facial asymmetry has been measured by the severity of deviation of the menton (Me) on posteroanterior (PA) cephalograms and three-dimensional (3D) computed tomography (CT). This study aimed to compare PA cephalograms and 3D CT regarding the severity of Me deviation and the direction of the Me. PA cephalograms and 3D CT images of 35 patients who underwent orthognathic surgery (19 males and 16 females, with an average age of 22.1±3.3 years) were retrospectively reviewed in this study. By measuring the distance and direction of the Me from the midfacial reference line and the midsagittal plane in the cephalograms and 3D CT, respectively, the x-coordinates (x1 and x2) of the Me were obtained in each image. The difference between the x-coordinates was calculated and statistical analysis was performed to compare the severity of Me deviation and the direction of the Me in the two imaging modalities. A statistically significant difference in the severity of Me deviation was found between the two imaging modalities (Δx=2.45±2.03 mm, p<0.05) using the one-sample t-test. Statistically significant agreement was observed in the presence of deviation (k=0.64, p<0.05) and in the severity of Me deviation (k=0.27, p<0.05). A difference in the direction of the Me was detected in three patients (8.6%). The severity of the Me deviation was found to vary according to the imaging modality in 16 patients (45.7%). The measurement of Me deviation may be different between PA cephalograms and 3D CT in some patients

  19. Three-dimensional flow structure measurements behind a queue of studied model vehicles

    International Nuclear Information System (INIS)

    Huang, J.F.; Chan, T.L.; Zhou, Y.

    2009-01-01

    The three-dimensional flow structures of a queue of studied model vehicles (i.e., one-, two- and three-vehicle cases) were investigated comprehensively in a closed-circuit wind tunnel using particle image velocimetry (PIV) for the typical urban vehicle speeds (i.e., 10, 30 and 50 km/h). In this three-dimensional vehicle wake, a pair of longitudinal vortices is characterized by counter-rotating and moving downstream at relatively low velocity than their surrounding flow. The flow structures of multiple studied model vehicles are dominated by the wake generated from the last studied model vehicle but the preceding studied model vehicle(s) also has/have some minor effects. Cross-sectional turbulence distribution is non-uniform in the far-wake region for all studied cases. The lowest turbulence occurs at the center part of the vehicle wake while high turbulence occurs at its two sides. As such, it may lead to considerable underestimation in turbulence magnitude if the measurement is only taken along the centerline of the vehicle wake.

  20. Colour-coded three-dimensional reconstruction from spiral CT data sets: Improvement from the physical point of view

    International Nuclear Information System (INIS)

    Wunderlich, A.P.; Lenz, M.; Kirsten, R.; Gerhardt, P.

    1993-01-01

    This paper demonstrates the possibility of improving the spatial depth impression of colour-coded three-dimensional reconstructions by modulation of colour saturation. Patients were observed with spiral computed tomography (slice thickness 10 mm, table feed 10 mm/s, reconstruction of overlapping axial images at 2 mm increment). Interesting anatomical and pathological objects (vessels, organs, tumours, metastases) were segmented, colour-coded, and reconstructed three-dimensionally. Spatial depth impression of the coloured objects could be improved by modulating not only the brightness, but also the colour saturation. (orig.) [de

  1. Pre-operative CT angiography and three-dimensional image post processing for deep inferior epigastric perforator flap breast reconstructive surgery.

    Science.gov (United States)

    Lam, D L; Mitsumori, L M; Neligan, P C; Warren, B H; Shuman, W P; Dubinsky, T J

    2012-12-01

    Autologous breast reconstructive surgery with deep inferior epigastric artery (DIEA) perforator flaps has become the mainstay for breast reconstructive surgery. CT angiography and three-dimensional image post processing can depict the number, size, course and location of the DIEA perforating arteries for the pre-operative selection of the best artery to use for the tissue flap. Knowledge of the location and selection of the optimal perforating artery shortens operative times and decreases patient morbidity.

  2. Three-dimensional numerical study of heat transfer enhancement in separated flows

    Science.gov (United States)

    Kumar, Saurav; Vengadesan, S.

    2017-11-01

    The flow separation appears in a wide range of heat transfer applications and causes poor heat transfer performance. It motivates the study of heat transfer enhancement in laminar as well as turbulent flows over a backward facing step by means of an adiabatic fin mounted on the top wall. Recently, we have studied steady, 2-D numerical simulations in laminar flow and investigated the effect of fin length, location, and orientation. It revealed that the addition of fin causes enhancement of heat transfer and it is very effective to control the flow and thermal behavior. The fin is most effective and sensitive when it is placed exactly above the step. A slight displacement of the fin in upstream of the step causes the complete change of flow and thermal behavior. Based on the obtained 2-D results it is interesting to investigate the side wall effect in three-dimensional simulations. The comparison of two-dimensional and three-dimensional numerical simulations with the available experimental results will be presented. Special attention has to be given to capture unsteadiness in the flow and thermal field.

  3. Accuracy of renal volume assessment in children by three-dimensional sonography; Nierenvolumetrie im Kindesalter: Genauigkeit der dreidimensionalen Sonographie im Vergleich zur konventionellen Sonographie und CT/MRT

    Energy Technology Data Exchange (ETDEWEB)

    Fritz, G.A.; Riccabona, M.; Bohdal, G. [Klinik fuer Radiologie, Universitaetsklinikum Graz (Austria); Quehenberger, F. [Inst. fuer medizinische Informatik, Statistik und Dokumentation, Universitaetsklinikum Graz (Austria)

    2003-04-01

    Purpose: Prospective evaluation of the accuracy of three-dimensional ultrasound (3DUS) to assess the renal parenchymal volume. Materials and Methods: CT, MRI, 2DUS and 3DUS were used to measure the renal volume in 40 patients (range: neonate to 17 years; mean age: 8.95 years). The 3DUS was determined with a Voluson 730 (Kretztechnik, GE) or an external 3D-system (EchoTech, GE) using electromagnetic positioning sensors attached to conventional 2DUS-equipment. The 2DUS volume was calculated with the ellipsoid equation and the 3DUS volume computed with the system integrated software. For CT and MRI, planimetric analysis was used to determine the renal parenchymal volume, whereby the dilated collecting system of a hydronephrosis was subtracted to obtain the real renal parenchymal volume. The results of 2DUS and 3DUS were compared to the results of CT and MRI, and inter- and intraobserver variabilities were calculated. Results: In 74 of 77 kidneys, the 3DUS study was of diagnostic quality. The accuracy of the 3DUS volumes compared well to the CT and MRI volumes with a mean difference of -1.8 {+-} 4.6% versus a mean difference of -2.4 {+-} 15.4% for 2DUS. In normal kidneys, the accuracy was -2.6 {+-} 4.4% for 3DUS and -3.8 {+-} 14.7% for 2DUS. In hydronephrosis, the accuracy was +4.0 {+-} 5.9% and +9.6 {+-} 21.3%, respectively, indicating that 3DUS is more accurate than 2DUS, particularly in kidneys with a dilated collecting system. Inter- and intraobserver variabilities were {+-} 7.3% and {+-} 5.3%. Conclusion: For assessing the renal parenchymal volume in children, 3DUS is feasible and comparable to CT and MRI. (orig.) [German] Studienziel: Prospektive Evaluation der Genauigkeit des drei-dimensionalen Ultraschalls (3DUS) bei der Volumetrie der kindlichen Niere im Vergleich zur CT/MRT. Methode: Bei 40 Patienten (Alter: 0 - 17 Jahre) mit einer klinisch indizierten CT/MRT des Abdomens oder des Harntrakts wurde zusaetzlich ein 2D- und 3DUS inklusive Volumetrie des

  4. Three-dimensional analysis of rodent paranasal sinus cavities from X-ray computed tomography (CT) scans

    Science.gov (United States)

    Phillips, Jonathan E.; Ji, Lunan; Rivelli, Maria A.; Chapman, Richard W.; Corboz, Michel R.

    2009-01-01

    Continuous isometric microfocal X-ray computed tomography (CT) scans were acquired from an AKR/J mouse, Brown-Norway rat, and Hartley guinea pig. The anatomy and volume of the paranasal sinus cavities were defined from 2-dimensional (2-D) and 3-dimensional (3-D) CT images. Realistic 3-D images were reconstructed and used to determine the anterior maxillary, posterior maxillary, and ethmoid sinus cavity airspace volumes (mouse: 0.6, 0.7, and 0.7 mm3, rat: 8.6, 7.7, and 7.0 mm3, guinea pig: 63.5, 46.6 mm3, and no ethmoid cavity, respectively). The mouse paranasal sinus cavities are similar to the corresponding rat cavities, with a reduction in size, while the corresponding maxillary sinus cavities in the guinea pig are different in size, location, and architecture. Also, the ethmoid sinus cavity is connected by a common drainage pathway to the posterior maxillary sinus in mouse and rat while a similar ethmoid sinus was not present in the guinea pig. We conclude that paranasal sinus cavity airspace opacity (2-D) or volume (3-D) determined by micro-CT scanning may be used to conduct longitudinal studies on the patency of the maxillary sinus cavities of rodents. This represents a potentially useful endpoint for developing and testing drugs in a small animal model of sinusitis. PMID:19794893

  5. Definition of the supraclavicular and infraclavicular nodes: implications for three-dimensional CT-based conformal radiation therapy.

    Science.gov (United States)

    Madu, C N; Quint, D J; Normolle, D P; Marsh, R B; Wang, E Y; Pierce, L J

    2001-11-01

    To delineate with computed tomography (CT) the anatomic regions containing the supraclavicular (SCV) and infraclavicular (IFV) nodal groups, to define the course of the brachial plexus, to estimate the actual radiation dose received by these regions in a series of patients treated in the traditional manner, and to compare these doses to those received with an optimized dosimetric technique. Twenty patients underwent contrast material-enhanced CT for the purpose of radiation therapy planning. CT scans were used to study the location of the SCV and IFV nodal regions by using outlining of readily identifiable anatomic structures that define the nodal groups. The brachial plexus was also outlined by using similar methods. Radiation therapy doses to the SCV and IFV were then estimated by using traditional dose calculations and optimized planning. A repeated measures analysis of covariance was used to compare the SCV and IFV depths and to compare the doses achieved with the traditional and optimized methods. Coverage by the 90% isodose surface was significantly decreased with traditional planning versus conformal planning as the depth to the SCV nodes increased (P correlation was found between brachial plexus depth and SCV depth up to 7 cm. Conformal optimized planning provided improved dosimetric coverage compared with standard techniques.

  6. Three-dimensional neuroimaging

    International Nuclear Information System (INIS)

    Toga, A.W.

    1990-01-01

    This book reports on new neuroimaging technologies that are revolutionizing the study of the brain be enabling investigators to visualize its structure and entire pattern of functional activity in three dimensions. The book provides a theoretical and practical explanation of the new science of creating three-dimensional computer images of the brain. The coverage includes a review of the technology and methodology of neuroimaging, the instrumentation and procedures, issues of quantification, analytic protocols, and descriptions of neuroimaging systems. Examples are given to illustrate the use of three-dimensional enuroimaging to quantitate spatial measurements, perform analysis of autoradiographic and histological studies, and study the relationship between brain structure and function

  7. A numerical study of three-dimensional droplets spreading on chemically patterned surfaces

    KAUST Repository

    Zhong, Hua

    2016-09-26

    We study numerically the three-dimensional droplets spreading on physically flat chemically patterned surfaces with periodic squares separated by channels. Our model consists of the Navier-Stokes-Cahn-Hilliard equations with the generalized Navier boundary conditions. Stick-slip behavior and con-tact angle hysteresis are observed. Moreover, we also study the relationship between the effective advancing/receding angle and the two intrinsic angles of the surface patterns. By increasing the volume of droplet gradually, we find that the advancing contact line tends gradually to an equiangular octagon with the length ratio of the two adjacent sides equal to a fixed value that depends on the geometry of the pattern.

  8. A three-dimensional-weighted cone beam filtered backprojection (CB-FBP) algorithm for image reconstruction in volumetric CT-helical scanning

    International Nuclear Information System (INIS)

    Tang Xiangyang; Hsieh Jiang; Nilsen, Roy A; Dutta, Sandeep; Samsonov, Dmitry; Hagiwara, Akira

    2006-01-01

    Based on the structure of the original helical FDK algorithm, a three-dimensional (3D)-weighted cone beam filtered backprojection (CB-FBP) algorithm is proposed for image reconstruction in volumetric CT under helical source trajectory. In addition to its dependence on view and fan angles, the 3D weighting utilizes the cone angle dependency of a ray to improve reconstruction accuracy. The 3D weighting is ray-dependent and the underlying mechanism is to give a favourable weight to the ray with the smaller cone angle out of a pair of conjugate rays but an unfavourable weight to the ray with the larger cone angle out of the conjugate ray pair. The proposed 3D-weighted helical CB-FBP reconstruction algorithm is implemented in the cone-parallel geometry that can improve noise uniformity and image generation speed significantly. Under the cone-parallel geometry, the filtering is naturally carried out along the tangential direction of the helical source trajectory. By exploring the 3D weighting's dependence on cone angle, the proposed helical 3D-weighted CB-FBP reconstruction algorithm can provide significantly improved reconstruction accuracy at moderate cone angle and high helical pitches. The 3D-weighted CB-FBP algorithm is experimentally evaluated by computer-simulated phantoms and phantoms scanned by a diagnostic volumetric CT system with a detector dimension of 64 x 0.625 mm over various helical pitches. The computer simulation study shows that the 3D weighting enables the proposed algorithm to reach reconstruction accuracy comparable to that of exact CB reconstruction algorithms, such as the Katsevich algorithm, under a moderate cone angle (4 deg.) and various helical pitches. Meanwhile, the experimental evaluation using the phantoms scanned by a volumetric CT system shows that the spatial resolution along the z-direction and noise characteristics of the proposed 3D-weighted helical CB-FBP reconstruction algorithm are maintained very well in comparison to the FDK

  9. Approximation for discrete Fourier transform and application in study of three-dimensional interacting electron gas.

    Science.gov (United States)

    Yan, Xin-Zhong

    2011-07-01

    The discrete Fourier transform is approximated by summing over part of the terms with corresponding weights. The approximation reduces significantly the requirement for computer memory storage and enhances the numerical computation efficiency with several orders without losing accuracy. As an example, we apply the algorithm to study the three-dimensional interacting electron gas under the renormalized-ring-diagram approximation where the Green's function needs to be self-consistently solved. We present the results for the chemical potential, compressibility, free energy, entropy, and specific heat of the system. The ground-state energy obtained by the present calculation is compared with the existing results of Monte Carlo simulation and random-phase approximation.

  10. Equatorial spread F studies using SAMI3 with two-dimensional and three-dimensional electrostatics

    Directory of Open Access Journals (Sweden)

    H. C. Aveiro

    2013-12-01

    Full Text Available This letter presents a study of equatorial F region irregularities using the NRL SAMI3/ESF model, comparing results using a two-dimensional (2-D and a three-dimensional (3-D electrostatic potential solution. For the 3-D potential solution, two cases are considered for parallel plasma transport: (1 transport based on the parallel ambipolar field, and (2 transport based on the parallel electric field. The results show that the growth rate of the generalized Rayleigh–Taylor instability is not affected by the choice of the potential solution. However, differences are observed in the structures of the irregularities between the 2-D and 3-D solutions. Additionally, the plasma velocity along the geomagnetic field computed using the full 3-D solution shows complex structures that are not captured by the simplified model. This points out that only the full 3-D model is able to fully capture the complex physics of the equatorial F region.

  11. Study on improved procedure for determination of three dimensional distributions of the initial rock stresses. 3

    International Nuclear Information System (INIS)

    Mizuta, Yoshiaki

    2004-02-01

    In the fiscal year of 2003, our committee achieved the following work items during the contract period, from September 3rd, 2003 to February 13th, 2004. The more accurate numerical data with respect to the geological/geometrical conditions including the fault were provided from Tono Geoscience Center and the numerical models by Finite Element Method (FEM), Finite Difference Method (FDM) and Boundary Element Method (BEM) were built taking those strata data into account. For small region modeling by FEM, three layers models, Shoumasama model and Tono-Shoumasama model, as well as Tono Mine model, were constructed, and each strain state at the far field boundary was determined. In order to get better agreement in local stress states with the measured values, a far field strain state was determined to the modified model in which material properties of upper granite and lower granite are different. In intermediate region modeling by FDM, actual strata data was taken into account, whereas strata boundary was assumed to be horizontal in former modeling, and far field stress field was analyzed. Intermediate region modeling by BEM was also carried out and far field stress state was determined. In wide region modeling by FEM, the fault was build in the model and fault slip was taken into account, and evaluation of strain state at the far field boundary was carried out for inhomogeneous rock including fault. It was proposed to output three-dimensional distribution of the maximum shear stress coefficients in order to advance three-dimensional modeling. It will make clear effect of shape, scale and property of the fault on stress state characteristic. This report describes minutely the results of the studies mentioned above. (author)

  12. CT-based three-dimensional kinematic comparison of dart-throwing motion between wrists with malunited distal radius and contralateral normal wrists

    International Nuclear Information System (INIS)

    Lee, S.; Kim, Y.S.; Park, C.S.; Kim, K.G.; Lee, Y.H.; Gong, H.S.; Lee, H.J.; Baek, G.H.

    2014-01-01

    Aim: To compare motion of the capitate, scaphoid, and lunate in wrists with a malunited distal radius and contralateral normal wrists during dart-throwing motion (DTM) by three-dimensional kinematic studies using computed tomography (CT) images. Materials and methods: CT was performed simultaneously on both wrists in six patients with a unilateral distal radius malunion at three stepwise positions simulating DTM. Using volume registration technique, the kinematic variables of helical axis motion of the capitate, scaphoid, and lunate were calculated and compared between both wrists. The helical motion of the capitate was also evaluated in a scaphoid- and lunate-based coordinate system. Results: Among the average rotation and translation of the scaphoid, lunate, and capitate during DTM, only the average rotation of the capitate was significantly different between the uninjured (88.9°) and the injured (70°) wrist (p = 0.0075). Rotation of the capitate relative to the scaphoid (26.3° versus 37.8°, p = 0.029) or lunate (39.2° versus 59.3°, p = 0.028) was smaller in the malunited wrist. The centres of helical axis motion of the three carpal bones were located more dorsally and radially in the injured wrist. Conclusions: The present study showed that decreased DTM in wrists with a distal radius malunion resulted from decreased midcarpal motion. The present study of the capitate, scaphoid, and lunate in wrists with distal radius malunion might be the first to present a 3D kinematic analysis of the effect of distal radius malunion on the carpal bones

  13. Three-dimensional drip infusion CT cholangiography in patients with suspected obstructive biliary disease: a retrospective analysis of feasibility and adverse reaction to contrast material

    International Nuclear Information System (INIS)

    Persson, A; Dahlström, N; Smedby, Ö; Brismar, TB

    2006-01-01

    Computed Tomography Cholangiography (CTC) is a fast and widely available alternative technique to visualise hepatobiliary disease in patients with an inconclusive ultrasound when MRI cannot be performed. The method has previously been relatively unknown and sparsely used, due to concerns about adverse reactions and about image quality in patients with impaired hepatic function and thus reduced contrast excretion. In this retrospective study, the feasibility and the frequency of adverse reactions of CTC when using a drip infusion scheme based on bilirubin levels were evaluated. The medical records of patients who had undergone upper abdominal spiral CT with subsequent three-dimensional rendering of the biliary tract by means of CTC during seven years were retrospectively reviewed regarding serum bilirubin concentration, adverse reaction and presence of visible contrast media in the bile ducts at CT examination. In total, 153 consecutive examinations in 142 patients were reviewed. Contrast media was observed in the bile ducts at 144 examinations. In 110 examinations, the infusion time had been recorded in the medical records. Among these, 42 examinations had an elevated bilirubin value (>19 umol/L). There were nine patients without contrast excretion; 3 of which had a normal bilirubin value and 6 had an elevated value (25–133 umol/L). Two of the 153 examinations were inconclusive. One subject (0.7%) experienced a minor adverse reaction – a pricking sensation in the face. No other adverse effects were noted. We conclude that drip infusion CTC with an infusion rate of the biliary contrast agent iotroxate governed by the serum bilirubin value is a feasible and safe alternative to MRC in patients with and without impaired biliary excretion. In this retrospective study the feasibility and the frequency of adverse reactions when using a drip infusion scheme based on bilirubin levels has been evaluated

  14. Morphological changes of the internal structure of maxillae with tooth loss. Three-dimensional and mechanical analysis using micro-CT and finite element method

    International Nuclear Information System (INIS)

    Usami, Akinobu; Hara, Toshihiro; Ide, Yoshinobu

    2003-01-01

    The purpose of this study was to analyze the morphological and mechanical properties of the internal structures of maxillae at the molar region using a micro-CT system. Ten dentulous and edentulous maxillae were employed in this study. Images and angle information from all materials were taken by a micro-CT and 100 x 100 x 100 voxels were extracted from the fixed buccal and palatal molar regions in each material for three-dimensional morphological analysis of the internal structure. The bone volume fraction, trabecular thickness, trabecular separation and trabecular number were calculated. To analyze mechanical properties all voxels were converted to micro finite element models with element size of 33 x 33 x 33 μm 3 and maximal stiffness, axial stiffness and angle between the stiffest direction of trabecular and the axial loading direction (angleα) were determined using micro finite element method. In the result, the morphological changes including decrease of bone volume fraction, trabecular thickness and increase of trabecular separation were evident with tooth loss, although trabecular number was not changed. Mechanically, maximal stiffness was decreased with tooth loss at buccal region. However, the axial stiffness at buccal region was larger and the angleα was distributed widely in each edentulous maxilla, comparing to the same region of dentulous maxilla. These findings suggest that trabecular bone become thinner in both buccal and palatal regions, consequently maximal stiffness at buccal region become smaller with tooth loss. On the other hand, axial stiffness at the buccal region in edentulous was larger than one in dentulous. It seems to be caused by the change of the angleα. (author)

  15. Particle coagulation in molten metal based on three-dimensional analysis of cluster by x-ray micro-computer tomography (CT)

    International Nuclear Information System (INIS)

    Li, Tao; Shimasaki, Shin-ichi; Taniguchi, Shoji; Narita, Shunsuke; Uesugi, Kentaro

    2013-01-01

    Particle coagulation plays a key role in steel refining process to remove inclusions. Many research works focus on the behaviors of particle coagulation. To reveal its mechanism water model experiments have been performed by some researchers including the authors' group. In this paper, experiments of particle coagulation were carried out with molten Al including SiC particles in a mechanically agitated crucible with two baffles. Particle coagulation and formation of clusters were observed on the microscopy images of as-polished samples. Three-dimensional (3D) analysis of the clusters in solidified Al was implemented by X-ray micro CT available at SPring-8. The methods to distinguish clusters on two-dimensional (2D) cross-sectional images were discussed, which were established in the previous works by the present authors' group. The characteristics of the 3D SiC clusters and their 2D cross-sections were analyzed. The statistical ranges of the parameters for 2D clusters were used as criterions to distinguish the clusters on 2D microscopy images from the as-polished samples. The kinetics of SiC particle coagulation was studied by the measured cluster number density and size using our program to distinguish cluster in 2D cross-sectional images according to 3D information (DC-2D-3D). The calculated and experimental results of the SiC particle coagulation in molten Al agree well with each other. (author)

  16. Morphological characteristics of the bony birth canal in patients with developmental dysplasia of the hip (DDH). Investigation by three-dimensional CT

    Energy Technology Data Exchange (ETDEWEB)

    Kojima, Seiichi; Kobayashi, Seneki; Saito, Naoto; Nawata, Masashi; Horiuchi, Hiroshi; Takaoka, Kunio [Shinshu Univ., Matsumoto, Nagano (Japan). School of Medicine

    2001-07-01

    We investigated the three-dimensional morphological characteristics of the pelvis in adult female patients with developmental dysplasia of the hip (DDH), using computerized tomography (CT) images. Forty-two subjects with normal hips and 40 DDH patients were recruited for the study. In the DDH group, the average transverse diameter of the pelvic inlet was significantly less and the average transverse diameter of the pelvic outlet was significantly greater than the measurements in the normal group. Further, the bony birth canal in DDH patients exhibited a higher incidence of anthropoid-type geometry, as defined by a longer sagittal diameter relative to the transverse diameter of the pelvic inlet. These findings indicate a characteristic pelvic geometry and suggest different development of the pelvis in the transverse direction in DDH patients. In addition, the obstetric conjugate length/transverse diameter of the pelvic inlet ratio was correlated to the degree of severity of acetabular dysplasia. This finding suggests that DDH is a manifestation of a developmental characteristic of the pelvis. (author)

  17. The role of three-dimensional multidetector CT gastrography in the preoperative imaging of stomach cancer: Emphasis on detection and localization of the tumor

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Woong; Shin, Sang Soo; Heo, Suk Hee; Lim, Hyo Soon; Park, Young Kyu; Jeong, Yong Yeon; Kang, Heoung Keun [Chonnam National University Medical School, Gwangju (Korea, Republic of); Lim, Nam Yeol [Dept. of Radiology, Chonnam National University Hospital, Gwangju (Korea, Republic of)

    2015-02-15

    Multidetector CT (MDCT) gastrography has been regarded as a promising technique for the preoperative imaging of gastric cancer. It has the ability to produce various three-dimensional (3D) images. Because 3D reconstruction images are more effective and intuitive for recognizing abnormal changes in the gastric folds and subtle mucosal nodularity than two-dimensional images, 3D MDCT gastrography can enhance the detection rate of early gastric cancer, which, in turn, contributes to the improvement of the accuracy of preoperative tumor (T) staging. In addition, shaded surface display and tissue transition projection images provide a global view of the stomach, with the exact location of gastric cancer, which may replace the need for barium studies. In this article, we discuss technical factors in producing high-quality MDCT gastrographic images and present cases demonstrating the usefulness of MDCT gastrography for the detection and T staging of gastric cancer while emphasizing the significance of preoperative localization of gastric cancer in terms of surgical margin.

  18. Imaging the Aqueous Humor Outflow Pathway in Human Eyes by Three-dimensional Micro-computed Tomography (3D micro-CT)

    Energy Technology Data Exchange (ETDEWEB)

    C Hann; M Bentley; A Vercnocke; E Ritman; M Fautsch

    2011-12-31

    The site of outflow resistance leading to elevated intraocular pressure in primary open-angle glaucoma is believed to be located in the region of Schlemm's canal inner wall endothelium, its basement membrane and the adjacent juxtacanalicular tissue. Evidence also suggests collector channels and intrascleral vessels may have a role in intraocular pressure in both normal and glaucoma eyes. Traditional imaging modalities limit the ability to view both proximal and distal portions of the trabecular outflow pathway as a single unit. In this study, we examined the effectiveness of three-dimensional micro-computed tomography (3D micro-CT) as a potential method to view the trabecular outflow pathway. Two normal human eyes were used: one immersion fixed in 4% paraformaldehyde and one with anterior chamber perfusion at 10 mmHg followed by perfusion fixation in 4% paraformaldehyde/2% glutaraldehyde. Both eyes were postfixed in 1% osmium tetroxide and scanned with 3D micro-CT at 2 {mu}m or 5 {mu}m voxel resolution. In the immersion fixed eye, 24 collector channels were identified with an average orifice size of 27.5 {+-} 5 {mu}m. In comparison, the perfusion fixed eye had 29 collector channels with a mean orifice size of 40.5 {+-} 13 {mu}m. Collector channels were not evenly dispersed around the circumference of the eye. There was no significant difference in the length of Schlemm's canal in the immersed versus the perfused eye (33.2 versus 35.1 mm). Structures, locations and size measurements identified by 3D micro-CT were confirmed by correlative light microscopy. These findings confirm 3D micro-CT can be used effectively for the non-invasive examination of the trabecular meshwork, Schlemm's canal, collector channels and intrascleral vasculature that comprise the distal outflow pathway. This imaging modality will be useful for non-invasive study of the role of the trabecular outflow pathway as a whole unit.

  19. Intraoperative three-dimensional fluoroscopy after transpedicular positioning of Kirschner-wire versus conventional intraoperative biplanar fluoroscopic control: A retrospective study of 345 patients and 1880 pedicle screws

    Directory of Open Access Journals (Sweden)

    Ghassan Kerry

    2014-01-01

    Full Text Available Study Design: Retrospective study. Objective: The aim was to find out whether intraoperative three-dimensional imaging after transpedicular positioning of Kirschner wire (K-wire in lumbar and thoracic posterior instrumentation procedures is of benefit to the patients and if this technique is accurately enough to make a postoperative screw position control through computer tomography (CT dispensable. Patients and Methods: Lumbar and thoracic posterior instrumentation procedures conducted at our department between 2002 and 2012 were retrospectively reviewed. The patients were divided into two groups: group A, including patients who underwent intraoperative three-dimensional scan after transpedicular positioning of the K-wire and group B, including patients who underwent only intraoperative biplanar fluoroscopy. An early postoperative CT of the instrumented section was done in all cases to assess the screw position. The rate of immediate intraoperative correction of the K-wires in cases of mal-positioning, as well as the rate of postoperative screw revisions, was measured. Results: In general, 345 patients (1880 screws were reviewed and divided into two groups; group A with 225 patients (1218 screws and group B with 120 patients (662 screws. One patient (0.44% (one screw [0.082%] of group A underwent postoperative screw correction while screw revisions were necessary in 14 patients (11.7% (28 screws [4.2%] of group B. Twenty-three patients (10.2% (28 K-wires [2.3%] of group A underwent intraoperative correction due to primary intraoperative detected K-wire mal-position. None of the corrected K-wires resulted in a corresponding neurological deficit. Conclusion: Three-dimensional imaging after transpedicular K-wire positioning leads to solid intraoperative identification of misplaced K-wires prior to screw placement and reduces screw revision rates compared with conventional fluoroscopic control. When no clinical deterioration emerges, a

  20. Effect of the three-dimensional microstructure on the sound absorption of foams: A parametric study.

    Science.gov (United States)

    Chevillotte, Fabien; Perrot, Camille

    2017-08-01

    The purpose of this work is to systematically study the effect of the throat and the pore sizes on the sound absorbing properties of open-cell foams. The three-dimensional idealized unit cell used in this work enables to mimic the acoustical macro-behavior of a large class of cellular solid foams. This study is carried out for a normal incidence and also for a diffuse field excitation, with a relatively large range of sample thicknesses. The transport and sound absorbing properties are numerically studied as a function of the throat size, the pore size, and the sample thickness. The resulting diagrams show the ranges of the specific throat sizes and pore sizes where the sound absorption grading is maximized due to the pore morphology as a function of the sample thickness, and how it correlates with the corresponding transport parameters. These charts demonstrate, together with typical examples, how the morphological characteristics of foam could be modified in order to increase the visco-thermal dissipation effects.

  1. Studies of the nuclear three-body system with three dimensional Faddeev calculations

    Science.gov (United States)

    Liu, Hang

    A three-body system consists of either a bound state of three particles with definite binding energy or a beam of single particles scattered from a target, where two of the particles are bound. Of the particles are nucleons, the interactions between them are strong and short ranged. A theoretical framework for studying the dynamics of a nuclear three-body system is the Faddeev scheme. In this work the equation for three-body scattering and the bound state are formulated in momentum space, and directly solved in terms of vector variables. For three identical bosons the Faddeev equation for scattering is a three- dimensional inhomogeneous integral equation in five variables, and is solved by Padé summation. The equation for the bound state is a homogeneous one in three variables, and is solved by a Lanczos' type method. The corresponding algorithms are presented, and their numerical feasibility is demonstrated. Elastic as well as inelastic scattering processes in the intermediate energy regime up to 1 GeV incident energy are studied for the first within a Faddeev scheme. The two-body force employed is of Malfliet-Tjon type. Specific emphasis is placed on studying the convergence of the multiple scattering series given by the Faddeev equations. For the bound state, a three-body force of Fujita- Miyazawa type is incorporated in addition to the two-body force. The effects of this three-body force on the bound state properties are investigated.

  2. Three dimensional modeling of depositional geometries. A case study from Tofane Group (Dolomites, Italy).

    Science.gov (United States)

    Gattolin, G.; Franceschi, M.; Breda, A.; Teza, G.; Preto, N.

    2012-04-01

    At the end of the Early Carnian, the Carnian Pluvial Event (CPE) resulted in a major crisis of carbonate factories. The sharp change in carbonate production lead to a dramatic modifications in depositional geometries. Steep clinoforms of the high-relief pre-crisis carbonate platforms were replaced by low-angle ramps. Spatial characters of depositional geometries can be decisive in identifying the genesis of geological bodies. We here show how 3D modeling techniques can be applied to help in quantifying and highlighting their variations. As case study we considered two outcrops in the Tofane Group (Dolomites, Italy). The first outcrop (bottom of southern walls of Tofana di Rozes) exposes a platform-to-basin transect of pre- and post-crisis platforms, the second (Dibona hut) a clinostratified carbonate body deposited during the Carnian crisis. Outcrop conditions at both sites, with vertical and hardly accessible walls, make the field tracing of depositional geometries particularly challenging. Line drawing on high resolution pictures can help (e.g. for clinoforms), but its use for quantification is hampered by perspective deformation. Three dimensional acquisition and modeling allow to retrieve the true spatial characters of sedimentary bodies in these outcrops. The geometry of the carbonate body at Dibona (~ 15000 sqm) was acquired with terrestrial LiDAR, while for Tofana photogrammetric techniques were applied because of the extension of the outcrop itself (~ 240000 sqm) and the lack of suitable points of view for terrestrial laser scanning. At Tofana, field observations reveal the presence of tens-hundreds m large carbonate mounds grown on a pre-existing inclined surface, intercalated with skeletal carbonates and siltites-arenites. This system rapidly evolves into a carbonate-clastic ramp. Photogrammetric topography acquisition permitted to place and visualize geological features in a three dimensional frame, thus obtaining a conceptual sedimentological model. A 3

  3. Numerical study on the three-dimensional scroll volute flow of centrifugal compressor

    International Nuclear Information System (INIS)

    Bae, Hwang; Chang, Keun Shik; Yoon, Ju Sig; Park, Ki Cheol

    2005-01-01

    Three dimensional turbulent flow in the scroll volute of centrifugal compressor has been numerically investigated in this paper by solving the Navier-Stokes equations and k -ε equation model. The computational grid for the flow field of the scroll volute has been constructed based on the multi-block grid, which is good to avoid the central grid singularity as well as to make grid stretching toward the volute wall. Numerical result has been obtained for the three-dimensional flow of scroll volute. The straight conical volute flow is also solved and compared with the scroll volute data. This comparison contributed to comprehend the effect of scroll in the three-dimensional volute flow of a centrifugal compressor

  4. Real-time in situ three-dimensional integral videography and surgical navigation using augmented reality: a pilot study

    Science.gov (United States)

    Suenaga, Hideyuki; Hoang Tran, Huy; Liao, Hongen; Masamune, Ken; Dohi, Takeyoshi; Hoshi, Kazuto; Mori, Yoshiyuki; Takato, Tsuyoshi

    2013-01-01

    To evaluate the feasibility and accuracy of a three-dimensional augmented reality system incorporating integral videography for imaging oral and maxillofacial regions, based on preoperative computed tomography data. Three-dimensional surface models of the jawbones, based on the computed tomography data, were used to create the integral videography images of a subject's maxillofacial area. The three-dimensional augmented reality system (integral videography display, computed tomography, a position tracker and a computer) was used to generate a three-dimensional overlay that was projected on the surgical site via a half-silvered mirror. Thereafter, a feasibility study was performed on a volunteer. The accuracy of this system was verified on a solid model while simulating bone resection. Positional registration was attained by identifying and tracking the patient/surgical instrument's position. Thus, integral videography images of jawbones, teeth and the surgical tool were superimposed in the correct position. Stereoscopic images viewed from various angles were accurately displayed. Change in the viewing angle did not negatively affect the surgeon's ability to simultaneously observe the three-dimensional images and the patient, without special glasses. The difference in three-dimensional position of each measuring point on the solid model and augmented reality navigation was almost negligible (augmented reality system was highly accurate and effective for surgical navigation and for overlaying a three-dimensional computed tomography image on a patient's surgical area, enabling the surgeon to understand the positional relationship between the preoperative image and the actual surgical site, with the naked eye. PMID:23703710

  5. Study on super-resolution three-dimensional range-gated imaging technology

    Science.gov (United States)

    Guo, Huichao; Sun, Huayan; Wang, Shuai; Fan, Youchen; Li, Yuanmiao

    2018-04-01

    Range-gated three dimensional imaging technology is a hotspot in recent years, because of the advantages of high spatial resolution, high range accuracy, long range, and simultaneous reflection of target reflectivity information. Based on the study of the principle of intensity-related method, this paper has carried out theoretical analysis and experimental research. The experimental system adopts the high power pulsed semiconductor laser as light source, gated ICCD as the imaging device, can realize the imaging depth and distance flexible adjustment to achieve different work mode. The imaging experiment of small imaging depth is carried out aiming at building 500m away, and 26 group images were obtained with distance step 1.5m. In this paper, the calculation method of 3D point cloud based on triangle method is analyzed, and 15m depth slice of the target 3D point cloud are obtained by using two frame images, the distance precision is better than 0.5m. The influence of signal to noise ratio, illumination uniformity and image brightness on distance accuracy are analyzed. Based on the comparison with the time-slicing method, a method for improving the linearity of point cloud is proposed.

  6. Two- and three-dimensional proton NMR studies of apo-neocarzinostatin

    International Nuclear Information System (INIS)

    Xiaolian Gao; Burkhart, W.

    1991-01-01

    Neocarzinostatin (NCS) is an antitumor protein from Streptomyces carzinostaticus that is identical in apo-protein sequence with mitomalcin (MMC) from Streptomyces malayensis. The authors describe the use of apo-NCS as a model system for applying combined two-and three-dimensional (2D and 3D) proton NMR spectroscopy to the structure determination of proteins without isotope labeling. Strategies aimed at accurately assigning overlapped 2D cross-peaks by using semiautomated combined 2D and 3D data analysis are developed. Using this approach, they have assigned 99% of the protons, including those of the side chains, and identified about 1,270 intra- and interresidue proton-proton interactions (fixed distances are not included) in apo-NCS. Comparing these results with those reported recently on 2D NMR studies of apo-NCS demonstrated advantages of proton 3D NMR spectroscopy in protein spectral assignments. They are able to obtain more complete proton resonance and secondary structural assignments and find several misassignments in the earlier report. Strategies utilized in this work should be useful for developing automation procedures for spectral assignments

  7. Three-dimensional (3D) printed endovascular simulation models: a feasibility study.

    Science.gov (United States)

    Mafeld, Sebastian; Nesbitt, Craig; McCaslin, James; Bagnall, Alan; Davey, Philip; Bose, Pentop; Williams, Rob

    2017-02-01

    Three-dimensional (3D) printing is a manufacturing process in which an object is created by specialist printers designed to print in additive layers to create a 3D object. Whilst there are initial promising medical applications of 3D printing, a lack of evidence to support its use remains a barrier for larger scale adoption into clinical practice. Endovascular virtual reality (VR) simulation plays an important role in the safe training of future endovascular practitioners, but existing VR models have disadvantages including cost and accessibility which could be addressed with 3D printing. This study sought to evaluate the feasibility of 3D printing an anatomically accurate human aorta for the purposes of endovascular training. A 3D printed model was successfully designed and printed and used for endovascular simulation. The stages of development and practical applications are described. Feedback from 96 physicians who answered a series of questions using a 5 point Likert scale is presented. Initial data supports the value of 3D printed endovascular models although further educational validation is required.

  8. Three-dimensional analysis of a ballet dancer with ischial tuberosity apophysitis. A case study.

    Science.gov (United States)

    Pohjola, Hanna; Sayers, Mark; Mellifont, Rebecca; Mellifont, Daniel; Venojärvi, Mika

    2014-12-01

    The purpose of this case study was to describe the three-dimensional biomechanics of common ballet exercises in a ballet dancer with ischial tuberosity apophysitis. This was achieved by comparing kinematics between the symptomatic (i.e. ischial apophyseal symptoms) and contralateral lower limbs, as well as via reported pain. Results suggest consistent differences in movement patterns in this dancer. These differences included: 1) decreased external rotation of contralateral hip, hence a decreased hip contribution to 'turn out'; 2) increased contralateral knee adduction and internal rotation; 3) an apparent synchronicity in the contralateral lower limb of the decreased hip external rotation and increased knee adduction; and 4) minimal use of ankle plantar/dorsiflexion movement for symptomatic side. Pain related to the left ischial apophysitis was associated with reduced amplitudes especially in fast ballet movements that required large range of motion in flexion and adduction in the left hip joint. These findings suggest that ischial apophysitis may limit dancer's ballet technique and performance. Key PointsThe pain related to the left ischial apophysitis was associated with reduced amplitudes especially in fast ballet movements that require large range of motion. This may affect to the lower limbs kinematics, and limit dancer's technique and performance.Compensatory strategies in the kinetic chain, differences in the joint angles between the lower limbs, traction forces, velocity and amplitude demands should be taken in consideration while training and rehabilitation of the ischial apophyseal injury within classical ballet.

  9. Three-Dimensional Analysis of a Ballet Dancer with Ischial Tuberosity Apophysitis. A Case Study

    Directory of Open Access Journals (Sweden)

    Hanna Pohjola

    2014-12-01

    Full Text Available The purpose of this case study was to describe the three-dimensional biomechanics of common ballet exercises in a ballet dancer with ischial tuberosity apophysitis. This was achieved by comparing kinematics between the symptomatic (i.e. ischial apophyseal symptoms and contralateral lower limbs, as well as via reported pain. Results suggest consistent differences in movement patterns in this dancer. These differences included: 1 decreased external rotation of contralateral hip, hence a decreased hip contribution to ‘turn out’; 2 increased contralateral knee adduction and internal rotation; 3 an apparent synchronicity in the contralateral lower limb of the decreased hip external rotation and increased knee adduction; and 4 minimal use of ankle plantar/dorsiflexion movement for symptomatic side. Pain related to the left ischial apophysitis was associated with reduced amplitudes especially in fast ballet movements that required large range of motion in flexion and adduction in the left hip joint. These findings suggest that ischial apophysitis may limit dancer’s ballet technique and performance.

  10. Quantitative study of two- and three-dimensional strong localization of matter waves by atomic scatterers

    International Nuclear Information System (INIS)

    Antezza, Mauro; Castin, Yvan; Hutchinson, David A. W.

    2010-01-01

    We study the strong localization of atomic matter waves in a disordered potential created by atoms pinned at the nodes of a lattice, for both three-dimensional (3D) and two-dimensional (2D) systems. The localization length of the matter wave, the density of localized states, and the occurrence of energy mobility edges (for the 3D system), are numerically investigated as a function of the effective scattering length between the atomic matter wave and the pinned atoms. Both positive and negative matter wave energies are explored. Interesting features of the density of states are discovered at negative energies, where maxima in the density of bound states for the system can be interpreted in terms of bound states of a matter wave atom with a few pinned atomic scatterers. In 3D we found evidence of up to three mobility edges, one at positive energies, and two at negative energies, the latter corresponding to transitions between extended and localized bound states. In 2D, no mobility edge is found, and a rapid exponential-like increase of the localization length is observed at high energy.

  11. MAGNETOHYDRODYNAMICS STUDY OF THREE-DIMENSIONAL FAST MAGNETIC RECONNECTION FOR INTERMITTENT SNAKE-LIKE DOWNFLOWS IN SOLAR FLARES

    International Nuclear Information System (INIS)

    Shimizu, T.; Kondo, K.; Ugai, M.; Shibata, K.

    2009-01-01

    Three-dimensional instability of the spontaneous fast magnetic reconnection is studied with magnetohydrodynamics (MHD) simulation, where the two-dimensional model of the spontaneous fast magnetic reconnection is destabilized in three dimensions. In two-dimensional models, every plasma condition is assumed to be uniform in the sheet current direction. In that case, it is well known that the two-dimensional fast magnetic reconnection can be caused by current-driven anomalous resistivity, when an initial resistive disturbance is locally put in a one-dimensional current sheet. In this paper, it is studied whether the two-dimensional fast magnetic reconnection can be destabilized or not when the initial resistive disturbance is three dimensional, i.e., that which has weak fluctuations in the sheet current direction. According to our study, the two-dimensional fast magnetic reconnection is developed to the three-dimensional intermittent fast magnetic reconnection which is strongly localized in the sheet current direction. The resulting fast magnetic reconnection repeats to randomly eject three-dimensional magnetic loops which are very similar to the intermittent downflows observed in solar flares. In fact, in some observations of solar flares, the current sheet seems to be approximately one dimensional, but the fast magnetic reconnection is strongly localized in the sheet current direction, i.e., fully three dimensional. In addition, the observed plasma downflows as snake-like curves. It is shown that those observed features are consistent with our numerical MHD study.

  12. Advanced imaging of the musculoskeletal system: Standard, three-dimensional, and contrast-enhanced CT and MR imaging, and quantitative bone densitometry

    International Nuclear Information System (INIS)

    Resnick, D.; Sartoris, D.J.

    1987-01-01

    This course reviews the application of advanced imaging techniques to a broad spectrum of musculoskeletal disorders. The indications for and utility of standard CT in both the axial and the appendicular skeleton is explored. The combined use of CT with air and contrast arthrography at sites including the hip, knee, and shoulder is discussed. A summary of the proved and potential applications of MR imaging in osseous, articular, bone marrow, and soft-tissue disorders is provided. The utility of intraarticular contrast agents in enhancing the diagnostic capabilities of MR imaging for disorders of hyaline cartilage and and fibrocartilage is demonstrated. The advantages of multiplanar reformation and three-dimensional image reconstruction of cross-sectional imaging data are described in conjunction with the fundamental technological principles of these strategies. Accepted methods as well as investigative techniques for the diagnosis and follow-up of metabolic bone disease are contrasted with regard to relative indications, advantages, and limitations

  13. The advantage of the three dimensional computed tomographic (3 D-CT for ensuring accurate bone incision in sagittal split ramus osteotomy

    Directory of Open Access Journals (Sweden)

    Coen Pramono D

    2005-03-01

    Full Text Available Functional and aesthetic dysgnathia surgery requires accurate pre-surgical planning, including the surgical technique to be used related with the difference of anatomical structures amongst individuals. Programs that simulate the surgery become increasingly important. This can be mediated by using a surgical model, conventional x-rays as panoramic, cephalometric projections and another sophisticated method such as a three dimensional computed tomography (3 D-CT. A patient who had undergone double jaw surgeries with difficult anatomical landmarks was presented. In this case the mandible foramens were seen highly relatively related to the sigmoid notches. Therefore, ensuring the bone incisions in sagittal split was presumed to be difficult. A 3D-CT was made and considered to be very helpful in supporting the pre-operative diagnostic.

  14. Development of a dynamic CT system for neutron radiography and consecutive visualization of three-dimensional water behavior in a PEFC stack

    International Nuclear Information System (INIS)

    Murakawa, Hideki; Hashimoto, Michinori; Sugimoto, Katsumi; Asano, Hitoshi; Takenaka, Nobuyuki; Mochiki, Koh-ichi; Yasuda, Ryo

    2011-01-01

    A dynamic CT system was developed for visualization of consecutive three-dimensional water behavior in a PEFC stack for neutron radiography. The system is composed of a neutron image intensifier and a C-MOS high speed video camera. An operating stack with three cells based on the Japan Automobile Research Institute standard was visualized using the neutron radiography system at a research reactor JRR-3 in Japan Atomic Energy Agency. The dynamic water behavior in channels in the operating PEFC stack was clearly visualized every 15 seconds by using the system. The water amount in each cell was evaluated by the CT reconstructed images. It was shown that a cell voltage decreased gradually when the water increased and increased rapidly when the water was evacuated. It was estimated that the power generation stopped when the channel of a cell was partly filled with the water because the air supply was blocked to a cell in the stack. (author)

  15. Residual estuarine circulation in the Mandovi, a monsoonal estuary: A three-dimensional model study

    Digital Repository Service at National Institute of Oceanography (India)

    Vijith, V.; Shetye, S.R.; Baetens, K.; Luyten, P.; Michael, G.S.

    -dependence is forced by the Indian Summer Monsoon (ISM) and hence the estuary is referred to as a monsoonal estuary. In this paper, we use a three-dimensional, open source, hydrodynamic, numerical model to reproduce the observed annual salinity field in the Mandovi. We...

  16. Scaling up Three-Dimensional Science Learning through Teacher-Led Study Groups across a State

    Science.gov (United States)

    Reiser, Brian J.; Michaels, Sarah; Moon, Jean; Bell, Tara; Dyer, Elizabeth; Edwards, Kelsey D.; McGill, Tara A. W.; Novak, Michael; Park, Aimee

    2017-01-01

    The vision for science teaching in the Framework for K-12 Science Education and the Next Generation Science Standards requires a radical departure from traditional science teaching. Science literacy is defined as three-dimensional (3D), in which students engage in science and engineering practices to develop and apply science disciplinary ideas…

  17. Dynamic Three-Dimensional Geometry of the Aortic Valve Apparatus-A Feasibility Study

    NARCIS (Netherlands)

    Khamooshian, Arash; Amador, Yannis; Hai, Ting; Jeganathan, Jelliffe; Saraf, Maria; Mahmood, Eitezaz; Matyal, Robina; Khabbaz, Kamal R.; Mariani, Massimo; Mahmood, Feroze

    OBJECTIVE: To provide (1) an overview of the aortic valve (AV) apparatus anatomy and nomenclature, and (2) data regarding the normal AV apparatus geometry and dynamism during the cardiac cycle obtained from three-dimensional transesophageal echocardiography (3D TEE). DESIGN: Retrospective

  18. Three-dimensional kinematics of the equine metacarpophalangeal joint using x-ray reconstruction of moving morphology - a pilot study.

    Science.gov (United States)

    Childs, Bronwen A; Pugliese, Brenna R; Carballo, Cristina T; Miranda, Daniel L; Brainerd, Elizabeth L; Kirker-Head, Carl A

    2017-07-20

    X-ray reconstruction of moving morphology (XROMM) uses biplanar videoradiography and computed tomography (CT) scanning to capture three-dimensional (3D) bone motion. In XROMM, morphologically accurate 3D bone models derived from CT are animated with motion from videoradiography, yielding a highly accurate and precise reconstruction of skeletal kinematics. We employ this motion analysis technique to characterize metacarpophalangeal joint (MCPJ) motion in the absence and presence of protective legwear in a healthy pony. Our in vivo marker tracking precision was 0.09 mm for walk and trot, and 0.10 mm during jump down exercises. We report MCPJ maximum extension (walk: -27.70 ± 2.78° [standard deviation]; trot: -33.84 ± 4.94°), abduction/adduction (walk: 0.04 ± 0.24°; trot: -0.23 ± 0.35°) and external/internal rotations (walk: 0.30 ± 0.32°; trot: -0.49 ± 1.05°) indicating that the MCPJ in this pony is a stable hinge joint with negligible extra-sagittal rotations. No substantial change in MCPJ maximum extension angles or vertical ground reaction forces (GRFv) were observed upon application of legwear during jump down exercise. Neoprene boot application yielded -65.20 ± 2.06° extension (GRFv = 11.97 ± 0.67 N/kg) and fleece polo wrap application yielded -64.23 ± 1.68° extension (GRFv = 11.36 ± 1.66 N/kg), when compared to naked control (-66.11 ± 0.96°; GRFv = 12.02 ± 0.53 N/kg). Collectively, this proof of concept study illustrates the benefits and practical limitations of using XROMM to document equine MCPJ kinematics in the presence and absence of legwear.

  19. A simulation study of enhancement duration in three-dimensional contrast-enhanced MR angiography

    International Nuclear Information System (INIS)

    Ohkubo, Masaki; Ohgoshi, Yukio; Inoue, Tomoko; Naito, Kenichi; Suzuki, Kiyotaka

    2001-01-01

    In our study on three-dimensional (3D) contrast-enhanced MR angiography we performed a computer simulation to investigate quantitative vessel visibility. In the simulation, we evaluated the relative loss of signal intensity in a vessel due to shortened duration of contrast-enhancement. The mid-point of enhancement-duration was assumed to be at the point in which the data in the center of k-space (k y axis) was acquired. Signal intensity of a vessel decreased as the enhancement-duration was shortened and the diameter of the vessel was decreased. When the duration was shortened 40%, the signal intensity of a vessel in which the diameter was more than 2 pixels was preserved by approximately 70% or more. This suggests that the vessel visibility is high. When the duration was shortened 20%, the signal intensity of a vessel in which the diameter was less than 2 pixels decreased to less than approximately 40% or less. The simulation was confirmed by using 3D MR angiography with a tube phantom filled with Gd-DTPA to simulate a vessel model. At anytime during data acquisition, we could set the phantom on the region being scanned or take it out by using the ''pause'' function of the MR scanner. This made it possible to change the enhancement-duration to match the simulation. Results of the phantom study were comparable to those of the simulation, suggesting that the simulation was valid. Our results and simple techniques for both the simulation and the phantom study using the ''pause'' function, were considered useful in the study of 3D MR angiography. (author)

  20. Structural, functional and evolutionary study of in silico three dimensional model of pneumolysin

    International Nuclear Information System (INIS)

    Lutfullah, G.; Taj, S.; Bashir, K.; Khattak, S.U.

    2017-01-01

    Streptococcus pneumoniae, a gram-positive cocci shaped bacteria, is the major human pathogen, causing diseases like septic meningitis, otitis media, sinusitis, pneumonia and septicemia. The objective of present study is to gain more knowledge about the function of important domain of the toxin pneumolysin. This study aims to analyze the structural and functional features of pneumolysin and to investigate the residues involved in its pathogenicity.The major virulence factor of this bacterium is a protein, pneumolysin, which is the member of thiol-activated cytolysins. From the three dimensional homology model of the present study, it was found that pneumolysin has four domains, out of which domain 4 is of great importance. It was observed that Cys 428 and Trp 433 of pneumolysin are of great importance and any mutation in this region highly reduces its cytotoxicity. Cys 428 forms hydrophobic contact with Ala 373 and Trp 436 of the conserved region, while Trp 433 is bonded with Trp 436 and Arg 426 through hydrogen interactions .The particular cysteine residue is present at position 428 and is also sandwiched between beta-sheet and Trp 436. In pneumolysin, the undecapeptide or the Trp-rich loop spans the region (amino acid 427 to 437) and several single amino acid substitutions within this region reduce the cytolytic activity of pneumolysin by up to 99.9% as reported previously. The primary structure of pneumolysin has a total eight tryptophan residues and one cysteine. The undecapeptide region has three tryptophan and one cysteine residue containing 11 amino acid sequence i.e ECTGLAWEWWR. Cysteine 428 of pneumolysin present in trp-rich motif is responsible to act on cholestrol. Pairwise alignment reveals that pneumolysin do not have the N-terminus signal peptide sequence which is present in the template i.e. perfringolysin. This shows that pneumolysin is an intracellular protein and released only upon cell lysis. (author)

  1. Equilibrium vortex motion in two- and three-dimensional superconductors studied with a dc SQUID

    International Nuclear Information System (INIS)

    Shaw, T.J.; Lawrence Berkeley National Lab., CA

    1997-10-01

    The equilibrium motion of vortices in two- and three-dimensional superconductors has been studied with a dc Superconducting QUantum Interference Device (SQUID). This technique has the advantage of probing the system in a non-invasive manner as well as providing dynamic information over many decades in frequency. Through measurements of the spectral density of magnetic flux noise, S Φ (ω), as a function of temperature and applied magnetic field, the effects of proton and heavy ion irradiation on flux noise in crystals of YBa 2 Cu 3 O 7-δ have been measured and compared with the effects on the critical current, J c . Both proton and heavy ion irradiation proved effective at reducing S Φ (ω), with proton irradiation having a larger effect. Measurement of S Φ (ω) due to the equilibrium Kosterlitz-Thouless-Berezinskii transition in two-dimensional Josephson Junction Arrays (JJAs) was studied as a function of temperature for three different arrays and using three different sensors. S Φ is shown to obey dynamic scaling over as many as five decades in frequency, and estimates are made for the dynamic critical exponent z. An analytic theory for the high- and low-frequency behavior of S Φ (ω) is presented and compared to the measured data, with the result that the low-frequency behavior is well described by the theory but the high-frequency behavior is not. Other theories and numerical simulations are described and compared with the data, but none are completely satisfactory. Lastly, suggestions for necessary further theoretical work and possible future experimental work are suggested

  2. Effect of malaria on placental volume measured using three-dimensional ultrasound: a pilot study

    Directory of Open Access Journals (Sweden)

    Rijken Marcus J

    2012-01-01

    Full Text Available Abstract Background The presence of malaria parasites and histopathological changes in the placenta are associated with a reduction in birth weight, principally due to intrauterine growth restriction. The aim of this study was to examine the feasibility of studying early pregnancy placental volumes using three-dimensional (3D ultrasound in a malaria endemic area, as a small volume in the second trimester may be an indicator of intra-uterine growth restriction and placental insufficiency. Methods Placenta volumes were acquired using a portable ultrasound machine and a 3D ultrasound transducer and estimated using the Virtual Organ Computer-aided AnaLysis (VOCAL image analysis software package. Intra-observer reliability and limits of agreement of the placenta volume measurements were calculated. Polynomial regression models for the mean and standard deviation as a function of gestational age for the placental volumes of uninfected women were created and tested. Based on these equations each measurement was converted into a z -score. The z-scores of the placental volumes of malaria infected and uninfected women were then compared. Results Eighty-four women (uninfected = 65; infected = 19 with a posterior placenta delivered congenitally normal, live born, single babies. The mean placental volumes in the uninfected women were modeled to fit 5th, 10th, 50th, 90th and 95th centiles for 14-24 weeks' gestation. Most placenta volumes in the infected women were below the 50th centile for gestational age; most of those with Plasmodium falciparum were below the 10th centile. The 95% intra-observer limits of agreement for first and second measurements were ± 37.0 mL and ± 25.4 mL at 30 degrees and 15 degrees rotation respectively. Conclusion The new technique of 3D ultrasound volumetry of the placenta may be useful to improve our understanding of the pathophysiological constraints on foetal growth caused by malaria infection in early pregnancy.

  3. Changes in Mitral Annular Geometry after Aortic Valve Replacement: A Three-Dimensional Transesophageal Echocardiographic Study

    Science.gov (United States)

    Mahmood, Feroze; Warraich, Haider J.; Gorman, Joseph H.; Gorman, Robert C.; Chen, Tzong-Huei; Panzica, Peter; Maslow, Andrew; Khabbaz, Kamal

    2014-01-01

    Background and aim of the study Intraoperative real-time three-dimensional transesophageal echocardiography (RT-3D TEE) was used to examine the geometric changes that occur in the mitral annulus immediately after aortic valve replacement (AVR). Methods A total of 35 patients undergoing elective surgical AVR under cardiopulmonary bypass was enrolled in the study. Intraoperative RT-3D TEE was used prospectively to acquire volumetric echocardiographic datasets immediately before and after AVR. The 3D echocardiographic data were analyzed offline using TomTec® Mitral Valve Assessment software to assess changes in specific mitral annular geometric parameters. Results Datasets were successfully acquired and analyzed for all patients. A significant reduction was noted in the mitral annular area (-16.3%, p <0.001), circumference (-8.9% p <0.001) and the anteroposterior (-6.3%, p = 0.019) and anterolateral-posteromedial (-10.5%, p <0.001) diameters. A greater reduction was noted in the anterior annulus length compared to the posterior annulus length (10.5% versus 62%, p <0.05) after AVR. No significant change was seen in the non-planarity angle, coaptation depth, and closure line length. During the period of data acquisition before and after AVR, no significant change was noted in the central venous pressure or left ventricular end-diastolic diameter. Conclusion The mitral annulus undergoes significant geometric changes immediately after AVR Notably, a 16.3% reduction was observed in the mitral annular area. The anterior annulus underwent a greater reduction in length compared to the posterior annulus, which suggested the existence of a mechanical compression by the prosthetic valve. PMID:23409347

  4. Innervation pattern of the suprascapular nerve within supraspinatus: a three-dimensional computer modeling study.

    Science.gov (United States)

    Hermenegildo, J A; Roberts, S L; Kim, S Y

    2014-05-01

    The relationship between the innervation pattern of the suprascapular nerve (SSN) and the muscle architecture of supraspinatus has not been thoroughly investigated. The supraspinatus is composed of two architecturally distinct regions: anterior and posterior. Each of these regions is further subdivided into three parts: superficial, middle and deep. The purpose of this study was to investigate the course of the SSN throughout the volume of supraspinatus and to relate the intramuscular branches to the distinct regions and parts of the supraspinatus. The SSN was dissected in thirty formalin embalmed cadaveric specimens and digitized throughout the muscle volume in six of those specimens. The digitized data were modeled using Autodesk(®) Maya(®) 2011. The three-dimensional (3D) models were used to relate the intramuscular innervation pattern to the muscle and tendon architecture defined by Kim et al. (2007, Clin Anat 20:648-655). The SSN bifurcated into two main trunks: medial and lateral. All parts of the anterior region were predominantly innervated by the medial trunk and its proximal and medial branches, whereas all parts of the posterior region predominantly by the lateral trunk and its posterolateral and/or posteromedial branches. The posterior region also received innervation from the proximal branch of the medial trunk in half of the specimens. These findings provide evidence that the anterior and posterior regions are distinct with respect to their innervation. The 3D map of the innervation pattern will aid in planning future clinical studies investigating muscle activation patterns and provide insight into possible injury of the nerve with supraspinatus pathology and surgical techniques. Copyright © 2013 Wiley Periodicals, Inc.

  5. Three-dimensional study of pectoralis major muscle and tendon architecture.

    Science.gov (United States)

    Fung, Lillia; Wong, Brian; Ravichandiran, Kajeandra; Agur, Anne; Rindlisbacher, Tim; Elmaraghy, Amr

    2009-05-01

    A thorough understanding of the normal structural anatomy of the pectoralis major (PM) is of paramount importance in the planning of PM tendon transfers or repairs following traumatic PM tears. However, there is little consensus regarding the complex musculotendinous architecture of the PM in the anatomic or surgical literature. The purpose of this study is to model and quantify the three-dimensional architecture of the pectoralis muscle and tendon. Eleven formalin embalmed cadaveric specimens were examined: five (2M/3F) were serially dissected, digitized, and modeled in 3D using Autodesk Maya; six (4M/2F) were dissected and photographed. The PM tendon consisted of longer anterior and shorter posterior layers that were continuous inferiorly. The muscle belly consisted of an architecturally uniform clavicular head (CH) and a segmented sternal head (SH) with 6-7 segments. The most inferior SH segment in all specimens was found to fold anteriorly forming a trough that cradled the inferior aspect of the adjacent superior segment. No twisting of either the PM muscle or tendon was noted. Within the CH, the fiber bundle lengths (FBL) were found to increase from superior to inferior, whereas the mean FBLs of SH were greatest in segments 3-5 found centrally. The mean lateral pennation angle was greater in the CH (29.4 +/- 6.9 degrees ) than in the SH (20.6 +/- 2.7 degrees ). The application of these findings could form the basis of future studies to optimize surgical planning and functional recovery of repair/reconstruction procedures.

  6. The use of the co-ordinate measuring machine for the study of three-dimensional biomechanics of the knee.

    Science.gov (United States)

    Veselko, M; Jenko, M; Lipuscek, I

    1998-07-01

    Original methodology for the study of three-dimensional biomechanics of the knee is presented in the paper. Defining the geometry of the rigid body in the body-fixed reference frame and the orientation of the body-fixed reference frame in the global co-ordinate system are the theoretic basis. The data in the form of co-ordinates of the Cartesian frame are gathered by the co-ordinate measuring machine and analysed by specially computer program. The theory and a practical example of the study of the three-dimensional biomechanics of the knee are presented. Various possibilities of the use of the methodology are discussed.

  7. SU-E-T-429: Feasibility Study On Three-Dimensional GRID Therapy in Conventional Linacs

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Y; Meyer, J; Timmerman, R; Hrycushko, B; Chen, B; Saha, D; Jiang, S [UT Southwestern Medical Center, Dallas, TX (United States)

    2015-06-15

    Purpose: Two-dimensional GRID therapy, traditionally planned and delivered using a dedicated GRID block or MLC modulation, has shown clinical efficacy in treating bulky tumors. However, the large dose to normal tissues outside target can be limiting. We hypothesize that modulation in the third dimension will improve dose sparing of normal tissues, maximize the bystander effect within the target, and ultimately improve the therapy effectiveness. This study aims to investigate the feasibility of a three-dimensional GRID technique using conventional LINACs to achieve a 3D lattice of high dose volumes within a target. Methods: Datasets of patient’s having large tumor sizes were used to investigate the planning and delivering of 3D GRID using a Varian TrueBeam linac. Original patient contours of PTV are exported from a TPS to DICOManTX where 3D GRID targets are generated in programmable configurations. A structure of avoidance (SOA), i.e., PTV minus GRID targets, is also generated to facilitate inverse planning to achieve the desired pattern. The artificial structures were sent back to the TPS where an IMRT or VMAT plan is designed to deliver a desired high dose to GRID targets while minimizing the dose to the SOA as much as possible. Results: The programmable GRID target generator enables us to modify the target geometry to maximize the peak-to-valley ratio. Preliminary results show that plans based on spherical GRID targets achieve a higher peak-to-valley dose ratio compared with cylindrical targets. High dose spillage outside the target was eliminated. IMRT planning requires the number of beams to be larger than 16, while for VMAT the number of arcs should be at least 4 in order to achieve dosimetric goals. Conclusion: Planning and delivering 3D GRID therapy using conventional LINACs was shown to be feasible. More research and development are required before this new modality can be implemented clinically.

  8. Three-dimensional Huh7 cell culture system for the study of Hepatitis C virus infection

    Directory of Open Access Journals (Sweden)

    Uprichard Susan L

    2009-07-01

    Full Text Available Abstract Background In order to elucidate how Hepatitis C Virus (HCV interacts with polarized hepatocytes in vivo and how HCV-induced alterations in cellular function contribute to HCV-associated liver disease, a more physiologically relevant hepatocyte culture model is needed. As such, NASA-engineered three-dimensional (3-D rotating wall vessel (RWV bioreactors were used in effort to promote differentiation of HCV-permissive Huh7 hepatoma cells. Results When cultured in the RWV, Huh7 cells became morphologically and transcriptionally distinct from more standard Huh7 two-dimensional (2-D monolayers. Specifically, RWV-cultured Huh7 cells formed complex, multilayered 3-D aggregates in which Phase I and Phase II xenobiotic drug metabolism genes, as well as hepatocyte-specific transcripts (HNF4α, Albumin, TTR and α1AT, were upregulated compared to 2-D cultured Huh7 cells. Immunofluorescence analysis revealed that these HCV-permissive 3-D cultured Huh7 cells were more polarized than their 2D counterparts with the expression of HCV receptors, cell adhesion and tight junction markers (CD81, scavenger receptor class B member 1, claudin-1, occludin, ZO-1, β-Catenin and E-Cadherin significantly increased and exhibiting apical, lateral and/or basolateral localization. Conclusion These findings show that when cultured in 3-D, Huh7 cells acquire a more differentiated hepatocyte-like phenotype. Importantly, we show that these 3D cultures are highly permissive for HCV infection, thus providing an opportunity to study HCV entry and the effects of HCV infection on host cell function in a more physiologically relevant cell culture system.

  9. Three-dimensional model of the skull and the cranial bones reconstructed from CT scans designed for rapid prototyping process.

    Science.gov (United States)

    Skrzat, Janusz; Spulber, Alexandru; Walocha, Jerzy

    This paper presents the effects of building mesh models of the human skull and the cranial bones from a series of CT-scans. With the aid of computer so ware, 3D reconstructions of the whole skull and segmented cranial bones were performed and visualized by surface rendering techniques. The article briefly discusses clinical and educational applications of 3D cranial models created using stereolitographic reproduction.

  10. Three-dimensional reconstructions of the orbital floor by volume-rendering of multidetector-row CT data

    International Nuclear Information System (INIS)

    Yoshikawa, Tetsuya; Miyajima, Akira; Fujita, Yuko; Yamada, Kazuo

    2011-01-01

    The advent of 3D-CT has made the evaluation of complicated facial fractures much easier than before. However, its use in injuries involving the orbital floor has been limited by the difficulty of visualizing the thin bony structures given artifacts caused by the partial volume effect. Nevertheless, high-technology machines such as multidetector-row CT (MDCT) and new-generation software have improved the quality of 3D imaging, and this paper describes a procedure for obtaining better visualization of the orbital floor using a MDCT scanner. Forty trauma cases were subject to MDCT: 13 with injury to the orbital floor, and 27 without. All scans were performed in the standard manner, at slice thicknesses of 0.5 mm. 3D-CT images were created overlooking the orbital floor including soft tissue to minimize the pseudo-foramen artifacts produced through volume rendering. Bone deficits, fracture lines, and grafted bone were visible in the 3D images, and visualization was supported by the ready creation of stereoscopic images from MDCT volume data. Measurement of the pseudo-foramen revealed approximately half the artifacts to be less than 5 mm in diameter, suggesting practicality of this method without subjecting the patient to undue increases in radiation exposure in the treatment of cases involving injury to the orbital floor. (author)

  11. A three-dimensional definition of nodal spaces on the basis of CT images showing enlarged nodes for pelvic radiotherapy

    International Nuclear Information System (INIS)

    Portaluri, Maurizio; Bambace, Santa; Perez, Celeste; Angone, Grazia

    2005-01-01

    Purpose: To demonstrate that margins of each pelvic chain may be derived by verifying the bony and soft tissue structures around abnormal nodes on computed tomography (CT) slices. Methods and Materials: Twenty consecutive patients (16 males, 4 females; mean age, 66 years; range, 43-80 years) with radiologic diagnosis of nodal involvement by histologically proved cervix carcinoma (two), rectum carcinoma (three), prostate carcinoma (four), lymphoma (five), penis carcinoma (one), corpus uteri carcinoma (one), bladder carcinoma (two), cutis tumor (one), and soft-tissue sarcoma (one) were retrospectively reviewed. One hundred CT scans showing 85 enlarged pelvic nodes were reviewed by two radiation oncologists (M.P., S.B.), and two radiologists (C.P., G.A.). Results: The more proximal structures to each enlarged node or group of nodes were thus recorded in a clockwise direction. Conclusion: According to their frequency and visibility, craniocaudal, anterior, lateral, posterior and medial margins of common iliac, external and internal iliac nodal chains, obturator and pudendal nodes, and deep and superficial inguinal nodes were derived from CT observations

  12. Optical studies of three dimensional confinement in photonic and electronic systems

    International Nuclear Information System (INIS)

    Adawi, Ali Mohammad Ahmad

    2002-01-01

    In the first part of this thesis the optical properties of three dimensional opal photonic crystals are investigated. The samples were grown by sedimentation of silica spheres into a face centred cubic structure. Structural studies show that self assembled opal photonic crystals are polycrystalline materials consisting of misoriented domains of size 50 μm to 100 μm. The angle dependent transmission technique is used to characterise the stop band of the samples. Due to the weak refractive index contrast in opal photonic crystals, only stop bands along the [111] direction are observed. The experimental transmission spectra are compared with theoretical transmission spectra calculated according to a three dimensional model based on the transfer matrix method. The experimental stop band is found to be six times broader than the calculated one, and also the experimental Bragg attenuation length is found to be five to seven times larger than the calculated one. Angle resolved diffraction and scattering techniques are used to investigate the origin of the discrepancies between experiment and theory. Analysis of the diffraction spectra indicate that the samples consist of misoriented domains of thickness 10 μm with a Gaussian distribution of 10 deg FWHM around the [111] direction. The scattering spectra show a strong resonant enhancement at the centre or edges (depending on the refractive index contrast) of the stop band. This observation is attributed to the multiple incoherent backward/forward reflections between the sample domains. By analysing the balance of photon flux originating from a slab of opal the shape of the experimental transmission stop band is fully explained. To investigate the effect of an incomplete photonic structure on the emission properties of light sources located inside the photonic crystal, the samples were infiltrated with solutions of laser dyes having fluorescence bands which overlap with the photonic gap of the host crystal. The optical

  13. A Three-Dimensional Kinematic and Kinetic Study of the College-Level Female Softball Swing

    Directory of Open Access Journals (Sweden)

    Monica Milanovich, Steven M. Nesbit

    2014-03-01

    Full Text Available This paper quantifies and discusses the three-dimensional kinematic and kinetic characteristics of the female softball swing as performed by fourteen female collegiate amateur subjects. The analyses were performed using a three-dimensional computer model. The model was driven kinematically from subject swings data that were recorded with a multi-camera motion analysis system. Each subject used two distinct bats with significantly different inertial properties. Model output included bat trajectories, subject/bat interaction forces and torques, work, and power. These data formed the basis for a detailed analysis and description of fundamental swing kinematic and kinetic quantities. The analyses revealed that the softball swing is a highly coordinated and individual three-dimensional motion and subject-to-subject variations were significant in all kinematic and kinetic quantities. In addition, the potential effects of bat properties on swing mechanics are discussed. The paths of the hands and the centre-of-curvature of the bat relative to the horizontal plane appear to be important trajectory characteristics of the swing. Descriptions of the swing mechanics and practical implications are offered based upon these findings.

  14. Beam halo studies using a three-dimensional particle-core model

    Directory of Open Access Journals (Sweden)

    Ji Qiang

    2000-06-01

    Full Text Available In this paper we present a study of beam halo based on a three-dimensional particle-core model of an ellipsoidal bunched beam in a constant focusing channel including the effects of nonlinear rf focusing. For an initially mismatched beam, three linear envelope modes—a high frequency mode, a low frequency mode, and a quadrupole mode—are identified for an azimuthally symmetric bunched beam. The high frequency mode has three components all in phase; the low frequency mode has the transverse components in phase and the longitudinal component 180° out of phase; the quadrupole mode has no longitudinal component, and the two transverse components in the mode are 180° out of phase. We also study the case of an ellipsoidal bunched beam without azimuthal symmetry and find that the high frequency mode and the low frequency mode are still present but the quadrupole mode is replaced by a new mode with transverse components 180° out of phase and a nonzero longitudinal component. Previous studies, which generally addressed the situation where the longitudinal-to-transverse focusing strength is roughly 0.6 or less, conclude that the oscillation of the high frequency mode is predominantly transverse, and that of the low frequency mode is predominantly longitudinal. In this paper we present a systematic study of the features of the modes as a function of the longitudinal-to-transverse focusing strength ratio. We find that, when the ratio is greater than unity, the high frequency mode may contain a significant longitudinal component. Thus, excitation of the high frequency mode in this situation can be responsible for the formation of longitudinal beam halo. Furthermore, while previous studies have observed halo amplitudes roughly 2–3 times the matched beam edge, for the present parameters we observe much larger amplitudes (5 times or more. This is due to the fact that the longitudinal-to-transverse focusing ratio used here is greater than that of previous

  15. Two-dimensional and three-dimensional CT analysis of congenital hip dysplasia in the older child and adult

    International Nuclear Information System (INIS)

    Magid, D.; Fishman, E.K.; Brooker, A.F.; Sponseller, P.D.

    1987-01-01

    In the older child or adult with congenital dysplasia of the hip, a spectrum of developmental abnormalities of the femoral head, neck, and acetabulum produce progressive hip dysfunction, pain, and premature arthritis. Treatment is oriented to restoring normal and pain-free function, although (unlike the infant with successfully treated dislocation) a truly normal hip cannot be restored. For these patients, who may require extensive reconstruction, transaxial CT with both static 2D (coronal and sagittal) and animated volumetric 3D image reformatting offers the most complete, accurate, and integrated approach to diagnosis and therapeutic planning. Parameters preoperatively assessed include head subluxation, neck anteversion, quadrilateral plate thickness, degree of dysplasia, potential for concentric reduction, acetabular capacity, and muscle status. Postoperatively, both immediate and long-term results or complications are easily assessed and readily compared

  16. Real-time three dimensional CT and MRI to guide interventions for congenital heart disease and acquired pulmonary vein stenosis.

    Science.gov (United States)

    Suntharos, Patcharapong; Setser, Randolph M; Bradley-Skelton, Sharon; Prieto, Lourdes R

    2017-10-01

    To validate the feasibility and spatial accuracy of pre-procedural 3D images to 3D rotational fluoroscopy registration to guide interventional procedures in patients with congenital heart disease and acquired pulmonary vein stenosis. Cardiac interventions in patients with congenital and structural heart disease require complex catheter manipulation. Current technology allows registration of the anatomy obtained from 3D CT and/or MRI to be overlaid onto fluoroscopy. Thirty patients scheduled for interventional procedures from 12/2012 to 8/2015 were prospectively recruited. A C-arm CT using a biplane C-arm system (Artis zee, VC14H, Siemens Healthcare) was acquired to enable 3D3D registration with pre-procedural images. Following successful image fusion, the anatomic landmarks marked in pre-procedural images were overlaid on live fluoroscopy. The accuracy of image registration was determined by measuring the distance between overlay markers and a reference point in the image. The clinical utility of the registration was evaluated as either "High", "Medium" or "None". Seventeen patients with congenital heart disease and 13 with acquired pulmonary vein stenosis were enrolled. Accuracy and benefit of registration were not evaluated in two patients due to suboptimal images. The distance between the marker and the actual anatomical location was 0-2 mm in 18 (64%), 2-4 mm in 3 (11%) and >4 mm in 7 (25%) patients. 3D3D registration was highly beneficial in 18 (64%), intermediate in 3 (11%), and not beneficial in 7 (25%) patients. 3D3D registration can facilitate complex congenital and structural interventions. It may reduce procedure time, radiation and contrast dose.

  17. Microsurgical management of cerebral aneurysms based in CT angiography with three-dimensional reconstruction (3D-CTA) and without preoperative cerebral angiography

    International Nuclear Information System (INIS)

    Gonzalez-Darder, J.M.; Pesudo-Martinez, J.V.; Feliu-Tatay, R.A.

    2001-01-01

    Objective. To study the possibilities of the microsurgical management of ruptured intracranial aneurysms with the sole preoperative information provided by computed tomography angiography with three-dimensional reconstruction (3D-CTA). Methods. Patients were studied with 3D-CTA after diagnosis of subarachnoid hemorrhage. If the study had an adequate quality and revealed an aneurysm congruent with the clinical findings or neurological examination and/or with the location of the bleeding on computed tomography (CT) scan an early microsurgical clipping of the lesion was done. When the quality of the 3D-CTA study was not adequate or the quality being adequate displayed no lesions or the findings were not accurate enough to warrant direct microsurgical treatment, the patient was studied with cerebral digital substraction (DS) angiography. A total of 44 consecutive patients harboring a total of 47 intracranial aneurysms diagnosed by 3D-CTA and without preoperative DS angiography were submitted to microsurgical clipping and included in the study. Results. The overall mortality was 15.9 % and the favorable results evaluated 6 months after discharge by means of the Glasgow outcome scale reached 70.4 %. All lesions were successfully clipped. Surgery was done a mean of 4.1 days after the admission bleeding. A total of four microlesions undiagnosed by 3D-CTA were found at surgery and clipped. Postoperative DS angiography and necropsy findings were also used as control of the 3D-CTA findings but no additional information was provided excepting the finding in DS angiography of an asymptomatic intracavemous aneurysm. Therefore the sensitivity of the 3D-CTA for diagnosis of symtomatic aneurysms was 100 % and the overall sensitivity 90.4 %. Conclusions. We have reached similar results in patients operated on with or without preoperative angiography. 3D-CTA provides very valuable anatomical information, which has an additional value in the microsurgical treatment of aneurysms of the

  18. Comparative study of cranial anthropometric measurement by traditional calipers to computed tomography and three-dimensional photogrammetry.

    Science.gov (United States)

    Mendonca, Derick A; Naidoo, Sybill D; Skolnick, Gary; Skladman, Rachel; Woo, Albert S

    2013-07-01

    Craniofacial anthropometry by direct caliper measurements is a common method of quantifying the morphology of the cranial vault. New digital imaging modalities including computed tomography and three-dimensional photogrammetry are similarly being used to obtain craniofacial surface measurements. This study sought to compare the accuracy of anthropometric measurements obtained by calipers versus 2 methods of digital imaging.Standard anterior-posterior, biparietal, and cranial index measurements were directly obtained on 19 participants with an age range of 1 to 20 months. Computed tomographic scans and three-dimensional photographs were both obtained on each child within 2 weeks of the clinical examination. Two analysts measured the anterior-posterior and biparietal distances on the digital images. Measures of reliability and bias between the modalities were calculated and compared.Caliper measurements were found to underestimate the anterior-posterior and biparietal distances as compared with those of the computed tomography and the three-dimensional photogrammetry (P photogrammetry (P = 0.002). The coefficients of variation for repeated measures based on the computed tomography and the three-dimensional photogrammetry were 0.008 and 0.007, respectively.In conclusion, measurements based on digital modalities are generally reliable and interchangeable. Caliper measurements lead to underestimation of anterior-posterior and biparietal values compared with digital imaging.

  19. Three-dimensional interactive Molecular Dynamics program for the study of defect dynamics in crystals

    Science.gov (United States)

    Patriarca, M.; Kuronen, A.; Robles, M.; Kaski, K.

    2007-01-01

    The study of crystal defects and the complex processes underlying their formation and time evolution has motivated the development of the program ALINE for interactive molecular dynamics experiments. This program couples a molecular dynamics code to a Graphical User Interface and runs on a UNIX-X11 Window System platform with the MOTIF library, which is contained in many standard Linux releases. ALINE is written in C, thus giving the user the possibility to modify the source code, and, at the same time, provides an effective and user-friendly framework for numerical experiments, in which the main parameters can be interactively varied and the system visualized in various ways. We illustrate the main features of the program through some examples of detection and dynamical tracking of point-defects, linear defects, and planar defects, such as stacking faults in lattice-mismatched heterostructures. Program summaryTitle of program:ALINE Catalogue identifier:ADYJ_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/ADYJ_v1_0 Program obtainable from: CPC Program Library, Queen University of Belfast, N. Ireland Computer for which the program is designed and others on which it has been tested: Computers:DEC ALPHA 300, Intel i386 compatible computers, G4 Apple Computers Installations:Laboratory of Computational Engineering, Helsinki University of Technology, Helsinki, Finland Operating systems under which the program has been tested:True64 UNIX, Linux-i386, Mac OS X 10.3 and 10.4 Programming language used:Standard C and MOTIF libraries Memory required to execute with typical data:6 Mbytes but may be larger depending on the system size No. of lines in distributed program, including test data, etc.:16 901 No. of bytes in distributed program, including test data, etc.:449 559 Distribution format:tar.gz Nature of physical problem:Some phenomena involving defects take place inside three-dimensional crystals at times which can be hardly predicted. For this reason they are

  20. An Eoetvoes versus a Galileo experiment: A study in two versus three-dimensional physics

    International Nuclear Information System (INIS)

    Hughes, R.J.; Nieto, M.M.; Goldman, T.

    1988-01-01

    We show how the net effect of two new approximately cancelling (vector and scalar) gravitational forces could produce a measureable effect from a horizontal thin slab in an Eoetvoes experiment, yet yield a null result at the same level for a Galileo experiment. The resolution is an example of two-versus three-dimensional physics and the cancelling nature of the two forces. Using two different earth models, we apply this result to the Australian mine gravity data of Stacey et al., the Brookhaven Eoetvoes experiment of Thieberger, and the Colorado Galileo experiment of Niebauer et al. (orig.)

  1. Growth and optical studies of opal films as three-dimensional photonic crystals

    Energy Technology Data Exchange (ETDEWEB)

    Comoretto, D.; Grassi, R.; Marabelli, F.; Andreani, L.C

    2003-01-15

    Three-dimensional artificial opals showing photonic crystals properties are grown by self-assembly of polystyrene nanospheres. Atomic force microscopy (AFM) images of opal surfaces show domains with regular triangular and squared packing of the spheres separated by cracks whose relative fraction depends on the sample quality. The energy position of an optical pseudo gap in transmittance spectra is observed by varying the angle of incidence and is accounted for by theoretical calculations of the photonic band structure based on a plane-wave expansion method.

  2. Core followup studies of the Tarapur Reactors with the three dimensional BWR simulator COMTEG

    Energy Technology Data Exchange (ETDEWEB)

    Dwivedi, S. R.; Jagannathan, V.; Mohanakrishnan, P.; Srinivasan, K. R.; Rastogi, B. P.

    1976-07-01

    Both the units of the Tarapur Atomic Power Station started operation in the year 1969. Since then, these units have completed three cycles. For efficient operation and fuel management of these reactors, a three dimensional BWR simulator COMETG has been developed. The reactors are closely being followed using the simulator. The detailed analyses for cycle 3/4 operation of both the units are described in the paper. The results show very good agreement between calculated and measured values. It is concluded that reactor core behaviour could be predicted in a satisfactory manner with the core simulator COMETG.

  3. Application Of Three-Dimensional Videography To Human Motion Studies: Constraints, Assumptions, And Mathematics

    Science.gov (United States)

    Rab, George T.

    1988-02-01

    Three-dimensional human motion analysis has been used for complex kinematic description of abnormal gait in children with neuromuscular disease. Multiple skin markers estimate skeletal segment position, and a sorting and smoothing routine provides marker trajectories. The position and orientation of the moving skeleton in space are derived mathematically from the marker positions, and joint motions are calculated from the Eulerian transformation matrix between linked proximal and distal skeletal segments. Reproduceability has been excellent, and the technique has proven to be a useful adjunct to surgical planning.

  4. Growth and optical studies of opal films as three-dimensional photonic crystals

    International Nuclear Information System (INIS)

    Comoretto, D.; Grassi, R.; Marabelli, F.; Andreani, L.C.

    2003-01-01

    Three-dimensional artificial opals showing photonic crystals properties are grown by self-assembly of polystyrene nanospheres. Atomic force microscopy (AFM) images of opal surfaces show domains with regular triangular and squared packing of the spheres separated by cracks whose relative fraction depends on the sample quality. The energy position of an optical pseudo gap in transmittance spectra is observed by varying the angle of incidence and is accounted for by theoretical calculations of the photonic band structure based on a plane-wave expansion method

  5. Study of system for segmentation of images and elaboration of algorithms for three dimensional scene reconstruction

    International Nuclear Information System (INIS)

    Bufacchi, A.; Tripi, A.

    1995-09-01

    The aim of this paper is the presentation of a series of methodologies to recognize and to obtain a three-dimensional reconstruction of an inner architectural scene, using a gray level image obtained using a TV camera. In the first part of the work, a series of methods used to find the edges in an effective way are critically compared, obtaining a binary image, and then the application of the Hough transform to such binary image to find the straight lines in the original image are discussed. In the second part, an algorithm is shown in order to find the vanishing points in such image

  6. Three dimensional numerical simulation of a full scale CANDU reactor moderator to study temperature fluctuations

    International Nuclear Information System (INIS)

    Sarchami, Araz; Ashgriz, Nasser; Kwee, Marc

    2014-01-01

    Highlights: • 3D model of a Candu reactor is modeled to investigate flow distribution. • The results show the temperature distribution is not symmetrical. • Temperature contours show the hot regions at the top left-hand side of the tank. • Interactions of momentum flows and buoyancy flows create circulation zones. • The results indicate that the moderator tank operates in the buoyancy driven mode. -- Abstract: Three dimensional numerical simulations are conducted on a full scale CANDU Moderator and transient variations of the temperature and velocity distributions inside the tank are determined. The results show that the flow and temperature distributions inside the moderator tank are three dimensional and no symmetry plane can be identified. Competition between the upward moving buoyancy driven flows and the downward moving momentum driven flows in the center region of the tank, results in the formation of circulation zones. The moderator tank operates in the buoyancy driven mode and any small disturbances in the flow or temperature makes the system unstable and asymmetric. Different types of temperature fluctuations are noted inside the tank: (i) large amplitude are at the boundaries between the hot and cold; (ii) low amplitude are in the core of the tank; (iii) high frequency fluctuations are in the regions with high velocities and (iv) low frequency fluctuations are in the regions with lower velocities

  7. Three-dimensional image technology in forensic anthropology: Assessing the validity of biological profiles derived from CT-3D images of the skeleton

    Science.gov (United States)

    Garcia de Leon Valenzuela, Maria Julia

    This project explores the reliability of building a biological profile for an unknown individual based on three-dimensional (3D) images of the individual's skeleton. 3D imaging technology has been widely researched for medical and engineering applications, and it is increasingly being used as a tool for anthropological inquiry. While the question of whether a biological profile can be derived from 3D images of a skeleton with the same accuracy as achieved when using dry bones has been explored, bigger sample sizes, a standardized scanning protocol and more interobserver error data are needed before 3D methods can become widely and confidently used in forensic anthropology. 3D images of Computed Tomography (CT) scans were obtained from 130 innominate bones from Boston University's skeletal collection (School of Medicine). For each bone, both 3D images and original bones were assessed using the Phenice and Suchey-Brooks methods. Statistical analysis was used to determine the agreement between 3D image assessment versus traditional assessment. A pool of six individuals with varying experience in the field of forensic anthropology scored a subsample (n = 20) to explore interobserver error. While a high agreement was found for age and sex estimation for specimens scored by the author, the interobserver study shows that observers found it difficult to apply standard methods to 3D images. Higher levels of experience did not result in higher agreement between observers, as would be expected. Thus, a need for training in 3D visualization before applying anthropological methods to 3D bones is suggested. Future research should explore interobserver error using a larger sample size in order to test the hypothesis that training in 3D visualization will result in a higher agreement between scores. The need for the development of a standard scanning protocol focusing on the optimization of 3D image resolution is highlighted. Applications for this research include the possibility

  8. Image Quality and Radiation Dose of CT Coronary Angiography with Automatic Tube Current Modulation and Strong Adaptive Iterative Dose Reduction Three-Dimensional (AIDR3D.

    Directory of Open Access Journals (Sweden)

    Hesong Shen

    Full Text Available To investigate image quality and radiation dose of CT coronary angiography (CTCA scanned using automatic tube current modulation (ATCM and reconstructed by strong adaptive iterative dose reduction three-dimensional (AIDR3D.Eighty-four consecutive CTCA patients were collected for the study. All patients were scanned using ATCM and reconstructed with strong AIDR3D, standard AIDR3D and filtered back-projection (FBP respectively. Two radiologists who were blinded to the patients' clinical data and reconstruction methods evaluated image quality. Quantitative image quality evaluation included image noise, signal-to-noise ratio (SNR, and contrast-to-noise ratio (CNR. To evaluate image quality qualitatively, coronary artery is classified into 15 segments based on the modified guidelines of the American Heart Association. Qualitative image quality was evaluated using a 4-point scale. Radiation dose was calculated based on dose-length product.Compared with standard AIDR3D, strong AIDR3D had lower image noise, higher SNR and CNR, their differences were all statistically significant (P<0.05; compared with FBP, strong AIDR3D decreased image noise by 46.1%, increased SNR by 84.7%, and improved CNR by 82.2%, their differences were all statistically significant (P<0.05 or 0.001. Segments with diagnostic image quality for strong AIDR3D were 336 (100.0%, 486 (96.4%, and 394 (93.8% in proximal, middle, and distal part respectively; whereas those for standard AIDR3D were 332 (98.8%, 472 (93.7%, 378 (90.0%, respectively; those for FBP were 217 (64.6%, 173 (34.3%, 114 (27.1%, respectively; total segments with diagnostic image quality in strong AIDR3D (1216, 96.5% were higher than those of standard AIDR3D (1182, 93.8% and FBP (504, 40.0%; the differences between strong AIDR3D and standard AIDR3D, strong AIDR3D and FBP were all statistically significant (P<0.05 or 0.001. The mean effective radiation dose was (2.55±1.21 mSv.Compared with standard AIDR3D and FBP, CTCA

  9. Three-Dimensional post-myelographic CT reconstruction in the diagnosis and therapy planning for spinal development disorders; Dreidimensionale postmyelographische CT-Rekonstruktion in der Diagnostik und Therapieplanung spinaler Entwicklungsstoerungen

    Energy Technology Data Exchange (ETDEWEB)

    Wicht, L. [Strahlenklinik und Poliklinik, Virchow Klinikum, Humboldt-Univ. zu Berlin (Germany); Schedel, H. [Strahlenklinik und Poliklinik, Virchow Klinikum, Humboldt-Univ. zu Berlin (Germany); Benndorf, G. [Strahlenklinik und Poliklinik, Virchow Klinikum, Humboldt-Univ. zu Berlin (Germany); Beier, J. [Strahlenklinik und Poliklinik, Virchow Klinikum, Humboldt-Univ. zu Berlin (Germany); Haberl, H. [Neurochirurgische Abt., Virchow-Klinikum, Humboldt-Univ. zu Berlin (Germany); Felix, R. [Strahlenklinik und Poliklinik, Virchow Klinikum, Humboldt-Univ. zu Berlin (Germany)

    1996-05-01

    Dysrhaphia is often associated with severe osseous aberrations of the spine such as, for example scoliosis, hemivertebra, and synostosis. With the advanced possibilities of the post-processing of CT-data (segmentation, three-dimensional reconstruction), post-myelo-CT is an excellent method for the evaluation of osseous structures and the myelon in preoperative planning. (orig.) [Deutsch] Dysraphien gehen haeufig mit ausgepraegten ossaeren Veraenderungen der Wirbelsaeule wie Skoliose, Halbwirbelbildungen und Synostosen einher. Mit den verbesserten Moeglichkeiten der Datennachbearbeitung (Segmentierung, 3D-dimensionale Rekonstruktion) stellt die postmyelographische Computertomographie vor allem bei komplexen Fehlbildungen ein geeignetes Verfahren zur praeoperativen Beurteilung der ossaeren Strukturen der Wirbelsaeule und des Myelons dar. (orig.)

  10. Cherenkov radiation-based three-dimensional position-sensitive PET detector: A Monte Carlo study.

    Science.gov (United States)

    Ota, Ryosuke; Yamada, Ryoko; Moriya, Takahiro; Hasegawa, Tomoyuki

    2018-05-01

    Cherenkov radiation has recently received attention due to its prompt emission phenomenon, which has the potential to improve the timing performance of radiation detectors dedicated to positron emission tomography (PET). In this study, a Cherenkov-based three-dimensional (3D) position-sensitive radiation detector was proposed, which is composed of a monolithic lead fluoride (PbF 2 ) crystal and a photodetector array of which the signals can be readout independently. Monte Carlo simulations were performed to estimate the performance of the proposed detector. The position- and time resolution were evaluated under various practical conditions. The radiator size and various properties of the photodetector, e.g., readout pitch and single photon timing resolution (SPTR), were parameterized. The single photon time response of the photodetector was assumed to be a single Gaussian for the simplification. The photo detection efficiency of the photodetector was ideally 100% for all wavelengths. Compton scattering was included in simulations, but partly analyzed. To estimate the position at which a γ-ray interacted in the Cherenkov radiator, the center-of-gravity (COG) method was employed. In addition, to estimate the depth-of-interaction (DOI) principal component analysis (PCA), which is a multivariate analysis method and has been used to identify the patterns in data, was employed. The time-space distribution of Cherenkov photons was quantified to perform PCA. To evaluate coincidence time resolution (CTR), the time difference of two independent γ-ray events was calculated. The detection time was defined as the first photon time after the SPTR of the photodetector was taken into account. The position resolution on the photodetector plane could be estimated with high accuracy, by using a small number of Cherenkov photons. Moreover, PCA showed an ability to estimate the DOI. The position resolution heavily depends on the pitch of the photodetector array and the radiator

  11. Development of the three dimensional image display program for limited cone beam X-ray CT for dental use (Ortho-CT)

    International Nuclear Information System (INIS)

    Arai, Yoshinori; Hashimoto, Koji; Shinoda, Koji

    2000-01-01

    We have already developed and reported a limited cone beam X-ray CT system for dental use (Ortho-CT). This system has been used clinically since 1997. In this study, we report a 3D surface display program for Ortho-CT which has been newly-developed by the authors. The 3D surface display software has been developed using visual C ++ (Microsoft Co. WA. USA) and a personal computer (Pentium 450MHz Intel Co. CA USA, Windows NT 4.0 Microsoft WA. USA). In this software, the 3D surface images are recorded as AVI files and can be displayed on the personal computer. The 3D images can be rotated and a stepwise change of the threshold voxel value for binary image formation can be automatically used. We have applied these 3D surface images to clinical studies from January 1999 to May 1999 at the Radiology section in our Dental hospital. The images can be displayed very easily in personal computers using AVI files. Thirty-five cases have been reconstructed using 3D surface images in this way. The 3D surface image is useful in the diagnosis of fractures of the mandibular head and impacted teeth. Only teeth are observed when a relative threshold voxel value is set at a high level such as about 0.37. When the threshold is changed to a lower value (about 0.3), we can observe both teeth and the surface of the bone. We have developed a 3D surface display program for personal computers. The images are useful for the diagnosis of the pathosis in the maxillofacial region. (author)

  12. Partial molar volume of proteins studied by the three-dimensional reference interaction site model theory.

    Science.gov (United States)

    Imai, Takashi; Kovalenko, Andriy; Hirata, Fumio

    2005-04-14

    The three-dimensional reference interaction site model (3D-RISM) theory is applied to the analysis of hydration effects on the partial molar volume of proteins. For the native structure of some proteins, the partial molar volume is decomposed into geometric and hydration contributions using the 3D-RISM theory combined with the geometric volume calculation. The hydration contributions are correlated with the surface properties of the protein. The thermal volume, which is the volume of voids around the protein induced by the thermal fluctuation of water molecules, is directly proportional to the accessible surface area of the protein. The interaction volume, which is the contribution of electrostatic interactions between the protein and water molecules, is apparently governed by the charged atomic groups on the protein surface. The polar atomic groups do not make any contribution to the interaction volume. The volume differences between low- and high-pressure structures of lysozyme are also analyzed by the present method.

  13. Three-dimensional ray-tracing model for the study of advanced refractive errors in keratoconus.

    Science.gov (United States)

    Schedin, Staffan; Hallberg, Per; Behndig, Anders

    2016-01-20

    We propose a numerical three-dimensional (3D) ray-tracing model for the analysis of advanced corneal refractive errors. The 3D modeling was based on measured corneal elevation data by means of Scheimpflug photography. A mathematical description of the measured corneal surfaces from a keratoconus (KC) patient was used for the 3D ray tracing, based on Snell's law of refraction. A model of a commercial intraocular lens (IOL) was included in the analysis. By modifying the posterior IOL surface, it was shown that the imaging quality could be significantly improved. The RMS values were reduced by approximately 50% close to the retina, both for on- and off-axis geometries. The 3D ray-tracing model can constitute a basis for simulation of customized IOLs that are able to correct the advanced, irregular refractive errors in KC.

  14. Multicenter study of quantitative computed tomography analysis using a computer-aided three-dimensional system in patients with idiopathic pulmonary fibrosis.

    Science.gov (United States)

    Iwasawa, Tae; Kanauchi, Tetsu; Hoshi, Toshiko; Ogura, Takashi; Baba, Tomohisa; Gotoh, Toshiyuki; Oba, Mari S

    2016-01-01

    To evaluate the feasibility of automated quantitative analysis with a three-dimensional (3D) computer-aided system (i.e., Gaussian histogram normalized correlation, GHNC) of computed tomography (CT) images from different scanners. Each institution's review board approved the research protocol. Informed patient consent was not required. The participants in this multicenter prospective study were 80 patients (65 men, 15 women) with idiopathic pulmonary fibrosis. Their mean age was 70.6 years. Computed tomography (CT) images were obtained by four different scanners set at different exposures. We measured the extent of fibrosis using GHNC, and used Pearson's correlation analysis, Bland-Altman plots, and kappa analysis to directly compare the GHNC results with manual scoring by radiologists. Multiple linear regression analysis was performed to determine the association between the CT data and forced vital capacity (FVC). For each scanner, the extent of fibrosis as determined by GHNC was significantly correlated with the radiologists' score. In multivariate analysis, the extent of fibrosis as determined by GHNC was significantly correlated with FVC (p < 0.001). There was no significant difference between the results obtained using different CT scanners. Gaussian histogram normalized correlation was feasible, irrespective of the type of CT scanner used.

  15. Three-dimensional CT might be a potential evaluation modality in correction of asymmetrical masseter muscle hypertrophy by botulinum toxin injection.

    Science.gov (United States)

    No, Yeon A; Ahn, Byeong Heon; Kim, Beom Joon; Kim, Myeung Nam; Hong, Chang Kwon

    2016-01-01

    For correction of this asymmetrical hypertrophy, botulinum toxin type A (BTxA) injection is one of convenient treatment modalities. Unfortunately, physical examination of masseter muscle is not enough to estimate the exact volume of muscle hypertrophy difference. Two Koreans, male and female, of bilateral masseter hypertrophy with asymmetricity were evaluated. BTxA (NABOTA(®), Daewoong, Co. Ltd., Seoul, Korea) was injected at master muscle site with total 50 U (25 U at each side) and volume change was evaluated with three-dimensional (3D) CT image analysis. Maximum reduction of masseter hypertrophy was recognized at 2-month follow-up and reduced muscle size started to restore after 3 months. Mean reduction of masseter muscle volume was 36% compared with baseline. More hypertrophied side of masseter muscle presented 42% of volume reduction at 2-month follow-up but less hypertrophied side of masseter muscle showed 30% of volume shrinkage. In conclusion, 3D CT image analysis might be the exact evaluation tool for correction of asymmetrical masseter hypertrophy by botulinum toxin injection.

  16. Semiautomatic three-dimensional CT ventricular volumetry in patients with congenital heart disease: agreement between two methods with different user interaction.

    Science.gov (United States)

    Goo, Hyun Woo; Park, Sang-Hyub

    2015-12-01

    To assess agreement between two semi-automatic, three-dimensional (3D) computed tomography (CT) ventricular volumetry methods with different user interactions in patients with congenital heart disease. In 30 patients with congenital heart disease (median age 8 years, range 5 days-33 years; 20 men), dual-source, multi-section, electrocardiography-synchronized cardiac CT was obtained at the end-systolic (n = 22) and/or end-diastolic (n = 28) phase. Nineteen left ventricle end-systolic (LV ESV), 28 left ventricle end-diastolic (LV EDV), 22 right ventricle end-systolic (RV ESV), and 28 right ventricle end-diastolic volumes (RV EDV) were successfully calculated using two semi-automatic, 3D segmentation methods with different user interactions (high in method 1, low in method 2). The calculated ventricular volumes of the two methods were compared and correlated. A P value volumetry shows good agreement and high correlation between the two methods, but method 2 tends to slightly underestimate LV ESV, LV EDV, and RV ESV.

  17. The experimental study of hydrodynamic characteristics of the overland flow on a slope with three-dimensional Geomat

    Science.gov (United States)

    Wang, Guang-yue; Sun, Guo-rui; Li, Jian-kang; Li, Jiong

    2018-02-01

    The hydrodynamic characteristics of the overland flow on a slope with a three-dimensional Geomat are studied for different rainfall intensities and slope gradients. The rainfall intensity is adjusted in the rainfall simulation system. It is shown that the velocity of the overland flow has a strong positive correlation with the slope length and the rainfall intensity, the scour depth decreases with the increase of the slope gradient for a given rainfall intensity, and the scour depth increases with the increase of the rainfall intensity for a given slope gradient, the overland flow starts with a transitional flow on the top and finishes with a turbulent flow on the bottom on the slope with the three-dimensional Geomat for different rainfall intensities and slope gradients, the resistance coefficient and the turbulent flow Reynolds number are in positively related logarithmic functions, the resistance coefficient and the slope gradient are in positively related power functions, and the trend becomes leveled with the increase of the rainfall intensity. This study provides some important theoretical insight for further studies of the hydrodynamic process of the erosion on the slope surface with a three-dimensional Geomat.

  18. Hísterossonografia tridimensional em infertilidade: estudo preliminar Three-dimensional hysterosonography in infertility: preliminary study

    Directory of Open Access Journals (Sweden)

    Nilka F. Donadio

    2004-12-01

    tratamento.PURPOSE: to compare the information obtained with pelvic and transvaginal ultrasonography (USG, hystero-salpingography (HSG, diagnostic hysteroscopy (HSC, pelvic nuclear magnetic resonance imaging (PNMR, three-dimensional hysterosonography (3D HSSNG, to optimize and simplify the investigation about cervical and corporeal uterine factors in conjugal infertility. METHODS: in the period between January and July 2003, fifty women reporting infertility for at least two years were submitted to USG, HSG, HSC, PNMR, and 3D HSSNG as tracking examinations for uterine factor diagnosis. The endocervical canal, as well as the endometrium, myometrium, and the presence of uterine malformations were investigated. The results of each examination were analyzed and compared. RESULTS: of the 50 women studied, 12 (24% presented alteration in at least one of the examinations. When 3D HSSNG was compared to USG, 3D HSSNG provided additional information in 7 cases (58.3%; when compared to HSG, it provided additional information in 7 cases (58.3%; when compared to HSC, it provided additional information in 4 cases (32.1%, and when compared to PNMR, it provided additional information in 6 cases (50%. There were only two cases in which HSG detected alterations of the endocervical canal that were not visualized using 3D HSSNG. In the other cases 3D HSSNG imparted the same diagnosis; furthermore, it provided additional information in comparison to the other examinations. Statistical analysis using the kappa test demonstrated that the diagnoses obtained by 3D HSSNG were in agreement with those obtained with USG, HSG and PNMR (p<0,05. When the HSG and 3D HSSNG results were combined, all conditions associated with infertility could be precisely diagnosed, using only these examinations. CONCLUSION: the association of the HSG with 3D HSSNG may be sufficient for the diagnosis of cervical and corporeal uterine factors in infertility, reducing the number of examinations for each patient, the total

  19. Three-dimensional Mass Measurement of Subsolid Pulmonary Nodules on Chest CT: Intra and Inter-observer Variability

    Directory of Open Access Journals (Sweden)

    Huiting LIU

    2015-05-01

    Full Text Available Background and objective Subsolid pulmonary nodules tend to exhibit considerably slower growth rates than solid lesions, nevertheless, higher malignancy probability. The diagnosis of indeterminate nodules largely depends on the growth evaluation during follow-up. The growth can manifested as an increase in size or the appearance and/or subsequent increase of solid components. The mass reflect the product of volume and density and can be more sensitive in growth evaluation. However, the repeatability needs a further validation. The purpose of this study is to assess the intra and inter-observer variability of mass measurement for subsolid nodules. Methods 80 subsolid nodules in 44 patients were retrospectively enrolled. Both the volume and mass were measured by two radiologists using blind method independently. Intra-observer and inter-observer variability were analyzed and compared by Bland-Altman method intra-class correlation test and Wilcoxon test. Results Software achieved satisfied segmentation for 92.5% nodules. Of them, 35% underwent manual modification. The 95% limits of agreement for intra-observer variability were -11.5%-10.4% for mass and -8.4%-8.8% for volume. The 95% limits of agreement for inter-observer variability were -17.4%-19.3% for mass and -17.9%-19.4% for volume.The intra-class correlation foefficients between volume and mass measument was 0.95 and 0.93 (both P<0.001 and no significant differences (P=0.78, 0.09 was found for intra- and inter-observer variability. Manual modification of the segmentation caused the worse mass measurement repeatability in spite of the reader satisfaction. Conclusion The repeatability of mass measurement has no significant difference with that of volume measurement and may act as a reliable method in the follow-up of subsolid nodules.

  20. The study of three-dimensional net method of deformation observation

    International Nuclear Information System (INIS)

    Jia Jinyun

    1996-12-01

    Due to the influence of all kinds of factors, when buildings and equipment of nuclear power stations, water power stations and so on are in their service, deformations always happen to them. Especially, the breakage, the slide of edge danger rocks and basic displacement in the area of nuclear power station site can all interfere its regular operation, even endanger safety. But the traditional trigonometric net control can not obtain high precise deformation observation. So, topographic balanced vertical deviations are applied. The slope distance is divided rationally into horizontal and vertical components, then the precise vertical component is used to participate in restricting the deflection in order to enhance the observation post's precision. Meanwhile, the element model is selected, high precise monitoring net of three-dimensional deformation is set up, using astro-geodetic deflection of the vertical to correct the observation values. In this way, the earth error of height is given, the plane coordinate is defined by paralleling some plane of reference ellipsoid. This method may satisfy the deformation observation in the projects such as nuclear power stations or so. (8 figs., 5 tabs.)

  1. High resolution three-dimensional robotic synthetic tracked aperture ultrasound imaging: feasibility study

    Science.gov (United States)

    Zhang, Haichong K.; Fang, Ting Yun; Finocchi, Rodolfo; Boctor, Emad M.

    2017-03-01

    Three dimensional (3D) ultrasound imaging is becoming a standard mode for medical ultrasound diagnoses. Conventional 3D ultrasound imaging is mostly scanned either by using a two dimensional matrix array or by motorizing a one dimensional array in the elevation direction. However, the former system is not widely assessable due to its cost, and the latter one has limited resolution and field-of-view in the elevation axis. Here, we propose a 3D ultrasound imaging system based on the synthetic tracked aperture approach, in which a robotic arm is used to provide accurate tracking and motion. While the ultrasound probe is moved by a robotic arm, each probe position is tracked and can be used to reconstruct a wider field-of-view as there are no physical barriers that restrict the elevational scanning. At the same time, synthetic aperture beamforming provides a better resolution in the elevation axis. To synthesize the elevational information, the single focal point is regarded as the virtual element, and forward and backward delay-andsum are applied to the radio-frequency (RF) data collected through the volume. The concept is experimentally validated using a general ultrasound phantom, and the elevational resolution improvement of 2.54 and 2.13 times was measured at the target depths of 20 mm and 110 mm, respectively.

  2. Three-dimensional printing of human skeletal muscle cells: An interdisciplinary approach for studying biological systems.

    Science.gov (United States)

    Bagley, James R; Galpin, Andrew J

    2015-01-01

    Interdisciplinary exploration is vital to education in the 21st century. This manuscript outlines an innovative laboratory-based teaching method that combines elements of biochemistry/molecular biology, kinesiology/health science, computer science, and manufacturing engineering to give students the ability to better conceptualize complex biological systems. Here, we utilize technology available at most universities to print three-dimensional (3D) scale models of actual human muscle cells (myofibers) out of bioplastic materials. The same methodological approach could be applied to nearly any cell type or molecular structure. This advancement is significant because historically, two-dimensional (2D) myocellular images have proven insufficient for detailed analysis of organelle organization and morphology. 3D imaging fills this void by providing accurate and quantifiable myofiber structural data. Manipulating tangible 3D models combats 2D limitation and gives students new perspectives and alternative learning experiences that may assist their understanding. This approach also exposes learners to 1) human muscle cell extraction and isolation, 2) targeted fluorescence labeling, 3) confocal microscopy, 4) image processing (via open-source software), and 5) 3D printing bioplastic scale-models (×500 larger than the actual cells). Creating these physical models may further student's interest in the invisible world of molecular and cellular biology. Furthermore, this interdisciplinary laboratory project gives instructors of all biological disciplines a new teaching tool to foster integrative thinking. © 2015 The International Union of Biochemistry and Molecular Biology.

  3. Three-dimensional studies of the 700 MWe steam generator design

    International Nuclear Information System (INIS)

    John, B.; Pietralik, J.

    2006-01-01

    The next stage in the Indian nuclear power programme envisions building 700 MWe Indian Pressurized Heavy Water Reactor (IPHWR) units. This involves up-rating of all the plant equipment including the reactor, steam generators (SGs), turbo-generator, major pumps, etc. The SG used in the current generation of 540 MWe IPHWRs, is a mushroom type, inverted U-tube, natural-circulation SG. The 700 MWe SG is of the same type and has the same tube bundle design and the same heat transfer area. The tube diameter, tube pitch, and outer diameter of the SG sections are the same as for the 540 MWe SG. The geometry of the feedwater header, the flow restrictor in the downcomer and the flow distribution plate are different in the two designs. The changes were required due to a 26% increase in steam flow rate while maintaining the same circulation ratio. This paper describes the design of the 700 MWe SG and a thermalhydraulic analysis using a one-dimensional, in-house code and a three-dimensional code called THIRST developed by AECL. The codes were validated against the 540 MWe SG data. The analysis was made for the 700 MWe SG for two versions: with and without integral preheater. The results of the THIRST runs were used for a flow-induced vibration analysis. The results of the flow-induced vibration analysis show that the vibrations are not excessive. (author)

  4. Three dimensional strained semiconductors

    Science.gov (United States)

    Voss, Lars; Conway, Adam; Nikolic, Rebecca J.; Leao, Cedric Rocha; Shao, Qinghui

    2016-11-08

    In one embodiment, an apparatus includes a three dimensional structure comprising a semiconductor material, and at least one thin film in contact with at least one exterior surface of the three dimensional structure for inducing a strain in the structure, the thin film being characterized as providing at least one of: an induced strain of at least 0.05%, and an induced strain in at least 5% of a volume of the three dimensional structure. In another embodiment, a method includes forming a three dimensional structure comprising a semiconductor material, and depositing at least one thin film on at least one surface of the three dimensional structure for inducing a strain in the structure, the thin film being characterized as providing at least one of: an induced strain of at least 0.05%, and an induced strain in at least 5% of a volume of the structure.

  5. Three-dimensional computerized mobilization of the cervical spine for the treatment of chronic neck pain: a pilot study.

    Science.gov (United States)

    River, Yaron; Aharony, Shelly; Bracha, Jillian; Levital, Tamir; Gerwin, Robert

    2014-07-01

    Manual therapies for chronic neck pain are imprecise, inconsistent, and brief due to therapist fatigue. A previous study showed that computerized mobilization of the cervical spine in the sagittal plane is a safe and potentially effective treatment of chronic neck pain. To investigate the safety and efficacy of computerized mobilization of the cervical spine in a three-dimensional space for the treatment of chronic neck pain. Pilot, open trial. Physical therapy outpatient department. Nine patients with chronic neck pain. A computerized cradle capable of three-dimensional neck mobilizations was used. Treatment sessions lasted 20 minutes, biweekly, for six weeks. Visual analog scale (VAS) for pain, cervical range of motion (CROM), neck disability index (NDI), joint position error (JPE), and muscle algometry. Comparing baseline at week one with week six (end of treatment), the VAS scores dropped by 2.9 points (P pain threshold in any muscle tested. There were no significant adverse effects. These preliminary results demonstrate that this novel, computerized, three-dimensional cervical mobilization device is probably safe. The data also suggest that this method is effective in alleviating neck pain and associated headache, and in increasing the CROM, although the sample size was small in this open trial. Wiley Periodicals, Inc.

  6. Prospective randomized comparison of rotational angiography with three-dimensional reconstruction and computed tomography merged with electro-anatomical mapping: a two center atrial fibrillation ablation study.

    Science.gov (United States)

    Anand, Rishi; Gorev, Maxim V; Poghosyan, Hermine; Pothier, Lindsay; Matkins, John; Kotler, Gregory; Moroz, Sarah; Armstrong, James; Nemtsov, Sergei V; Orlov, Michael V

    2016-08-01

    To compare the efficacy and accuracy of rotational angiography with three-dimensional reconstruction (3DATG) image merged with electro-anatomical mapping (EAM) vs. CT-EAM. A prospective, randomized, parallel, two-center study conducted in 36 patients (25 men, age 65 ± 10 years) undergoing AF ablation (33 % paroxysmal, 67 % persistent) guided by 3DATG (group 1) vs. CT (group 2) image fusion with EAM. 3DATG was performed on the Philips Allura Xper FD 10 system. Procedural characteristics including time, radiation exposure, outcome, and navigation accuracy were compared between two groups. There was no significant difference between the groups in total procedure duration or time spent for various procedural steps. Minor differences in procedural characteristics were present between two centers. Segmentation and fusion time for 3DATG or CT-EAM was short and similar between both centers. Accuracy of navigation guided by either method was high and did not depend on left atrial size. Maintenance of sinus rhythm between the two groups was no different up to 24 months of follow-up. This study did not find superiority of 3DATG-EAM image merge to guide AF ablation when compared to CT-EAM fusion. Both merging techniques result in similar navigation accuracy.

  7. Experimental study of soil-structure interaction for proving the three dimensional thin layered element method

    International Nuclear Information System (INIS)

    Kuwabara, Y.; Ogiwara, Y.; Suzuki, T.; Tsuchiya, H.; Nakayama, M.

    1981-01-01

    It is generally recognized that the earthquake response of a structure can be significantly affected by the dynamic interaction between the structure and the surrounding soil. Dynamic soil-structure interaction effects are usually analyzed by using a lumped mass model or a finite element model. In the lumped mass model, the soil is represented by springs and dashpots based on the half-space elastic theory. Each model has its advantages and limitations. The Three Dimensional Thin Layered Element Theory has been developed by Dr. Hiroshi Tajimi based on the combined results of the abovementioned lumped mass model and finite element model. The main characteristic of this theory is that, in consideration and can be applied in the analysis of many problems in soil-structure interaction, such as those involving radiation damping, embedded structures, and multi-layered soil deposits. This paper describes test results on a small scale model used to prove the validity of the computer program based on the Thin Layered Element Theory. As a numerical example, the response analysis of a PWR nuclear power plant is carried out using this program. The vibration test model is simplified and the scale is 1/750 for line. The soil layer of the model is made of congealed gelatine. The test soil layer is 80 cm long, 35 cm wide and 10 cm thick. The super structure is a one mass model made of metal sheet spring and solid mass metal. As fixed inputs, sinusoidal waves (10, 20 gal level) are used. The displacements of the top and base of the super structure, and the accelerations and the displacements of the shaking table are measured. The main parameter of the test is the shear wave velocity of the soil layer. (orig./RW)

  8. Usefulness of real-time three-dimensional ultrasonography in percutaneous nephrostomy: an animal study.

    Science.gov (United States)

    Hongzhang, Hong; Xiaojuan, Qin; Shengwei, Zhang; Feixiang, Xiang; Yujie, Xu; Haibing, Xiao; Gallina, Kazobinka; Wen, Ju; Fuqing, Zeng; Xiaoping, Zhang; Mingyue, Ding; Huageng, Liang; Xuming, Zhang

    2018-05-17

    To evaluate the effect of real-time three-dimensional (3D) ultrasonography (US) in guiding percutaneous nephrostomy (PCN). A hydronephrosis model was devised in which the ureters of 16 beagles were obstructed. The beagles were divided equally into groups 1 and 2. In group 1, the PCN was performed using real-time 3D US guidance, while in group 2 the PCN was guided using two-dimensional (2D) US. Visualization of the needle tract, length of puncture time and number of puncture times were recorded for the two groups. In group 1, score for visualization of the needle tract, length of puncture time and number of puncture times were 3, 7.3 ± 3.1 s and one time, respectively. In group 2, the respective results were 1.4 ± 0.5, 21.4 ± 5.8 s and 2.1 ± 0.6 times. The visualization of needle tract in group 1 was superior to that in group 2, and length of puncture time and number of puncture times were both lower in group 1 than in group 2. Real-time 3D US-guided PCN is superior to 2D US-guided PCN in terms of visualization of needle tract and the targeted pelvicalyceal system, leading to quick puncture. Real-time 3D US-guided puncture of the kidney holds great promise for clinical implementation in PCN. © 2018 The Authors BJU International © 2018 BJU International Published by John Wiley & Sons Ltd.

  9. Effective potential of the three-dimensional Ising model: The pseudo-ɛ expansion study

    Science.gov (United States)

    Sokolov, A. I.; Kudlis, A.; Nikitina, M. A.

    2017-08-01

    The ratios R2k of renormalized coupling constants g2k that enter the effective potential and small-field equation of state acquire the universal values at criticality. They are calculated for the three-dimensional scalar λϕ4 field theory (3D Ising model) within the pseudo-ɛ expansion approach. Pseudo-ɛ expansions for the critical values of g6, g8, g10, R6 =g6 / g42, R8 =g8 / g43 and R10 =g10 / g44 originating from the five-loop renormalization group (RG) series are derived. Pseudo-ɛ expansions for the sextic coupling have rapidly diminishing coefficients, so addressing Padé approximants yields proper numerical results. Use of Padé-Borel-Leroy and conformal mapping resummation techniques further improves the accuracy leading to the values R6* = 1.6488 and R6* = 1.6490 which are in a brilliant agreement with the result of advanced lattice calculations. For the octic coupling the numerical structure of the pseudo-ɛ expansions is less favorable. Nevertheless, the conform-Borel resummation gives R8* = 0.868, the number being close to the lattice estimate R8* = 0.871 and compatible with the result of 3D RG analysis R8* = 0.857. Pseudo-ɛ expansions for R10* and g10* are also found to have much smaller coefficients than those of the original RG series. They remain, however, fast growing and big enough to prevent obtaining fair numerical estimates.

  10. Retrospectively ECG-gated multi-detector row CT of the chest: does ECG-gating improve three-dimensional visualization of the bronchial tree?

    International Nuclear Information System (INIS)

    Schertler, T.; Wildermuth, S.; Willmann, J.K.; Crook, D.W.; Marincek, B.; Boehm, T.

    2004-01-01

    Purpose: To determine the impact of retrospectively ECG-gated multi-detector row CT (MDCT) on three-dimensional (3D) visualization of the bronchial tree and virtual bronchoscopy (VB) as compared to non-ECG-gated data acquisition. Materials and Methods: Contrast-enhanced retrospectively ECG-gated and non-ECG-gated MDCT of the chest was performed in 25 consecutive patients referred for assessment of coronary artery bypass grafts and pathology of the ascending aorta. ECG-gated MDCT data were reconstructed in diastole using an absolute reverse delay of -400 msec in all patients. In 10 patients additional reconstructions at -200 msec, -300 msec, and -500 msec prior to the R-wave were performed. Shaded surface display (SSD) and virtual bronchoscopy (VB) for visualization of the bronchial segments was performed with ECG-gated and non-ECG-gated MDCT data. The visualization of the bronchial tree underwent blinded scoring. Effective radiation dose and signal-to-noise ratio (SNR) for both techniques were compared. Results: There was no significant difference in visualizing single bronchial segments using ECG-gated compared to non-ECG-gated MDCT data. However, the total sum of scores for all bronchial segments visualized with non-ECG-gated MDCT was significantly higher compared to ECG-gated MDCT (P [de

  11. Abnormal course of the vertebral artery at the craniovertebral junction in patients with Down syndrome visualized by three-dimensional CT angiography

    International Nuclear Information System (INIS)

    Yamazaki, Masashi; Okawa, Akihiko; Hashimoto, Mitsuhiro; Aiba, Atsuomi; Someya, Yukio; Koda, Masao

    2008-01-01

    We determined the incidence of vertebral artery (VA) anomalies at the craniovertebral junction (CVJ) in patients with Down syndrome, and characterized the VA anomalies. The course of the VA in 46 consecutive patients who were due to undergo posterior arthrodesis surgery at the CVJ were evaluated by three-dimensional CT angiography (3DCTA). Included were five patients with Down syndrome who suffered from myelopathy due to atlantoaxial subluxation. All five patients with Down syndrome also had a simultaneous congenital skeletal anomaly, either os odontoideum or ossiculum terminale. Of the five patients with Down syndrome, three had VA anomalies at the CVJ, two had fenestration and one had a persistent first intersegmental artery. Of the other 41 patients without Down syndrome, five had VA anomalies at the CVJ. The incidence of VA anomalies at the CVJ was much higher in patients with Down syndrome than in those without Down syndrome. In planning surgery in patients with Down syndrome with symptomatic atlantoaxial subluxation and a congenital skeletal anomaly at the CVJ, we should consider the possible presence of VA anomalies. Preoperative 3DCTA allows us to precisely identify an anomalous VA and evaluate the possible risk of intraoperative VA injury in advance. (orig.)

  12. Abnormal course of the vertebral artery at the craniovertebral junction in patients with Down syndrome visualized by three-dimensional CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Yamazaki, Masashi; Okawa, Akihiko; Hashimoto, Mitsuhiro; Aiba, Atsuomi; Someya, Yukio; Koda, Masao [Chiba University Graduate School of Medicine, Spine Section, Department of Orthopaedic Surgery, Chiba (Japan)

    2008-06-15

    We determined the incidence of vertebral artery (VA) anomalies at the craniovertebral junction (CVJ) in patients with Down syndrome, and characterized the VA anomalies. The course of the VA in 46 consecutive patients who were due to undergo posterior arthrodesis surgery at the CVJ were evaluated by three-dimensional CT angiography (3DCTA). Included were five patients with Down syndrome who suffered from myelopathy due to atlantoaxial subluxation. All five patients with Down syndrome also had a simultaneous congenital skeletal anomaly, either os odontoideum or ossiculum terminale. Of the five patients with Down syndrome, three had VA anomalies at the CVJ, two had fenestration and one had a persistent first intersegmental artery. Of the other 41 patients without Down syndrome, five had VA anomalies at the CVJ. The incidence of VA anomalies at the CVJ was much higher in patients with Down syndrome than in those without Down syndrome. In planning surgery in patients with Down syndrome with symptomatic atlantoaxial subluxation and a congenital skeletal anomaly at the CVJ, we should consider the possible presence of VA anomalies. Preoperative 3DCTA allows us to precisely identify an anomalous VA and evaluate the possible risk of intraoperative VA injury in advance. (orig.)

  13. Validation of the blurring of a small object on CT images calculated on the basis of three-dimensional spatial resolution

    International Nuclear Information System (INIS)

    Okubo, Masaki; Wada, Shinichi; Saito, Masatoshi

    2005-01-01

    We determine three-dimensional (3D) blurring of a small object on computed tomography (CT) images calculated on the basis of 3D spatial resolution. The images were characterized by point spread function (PSF), line spread function (LSF) and slice sensitivity profile (SSP). In advance, we systematically arranged expressions in the model for the imaging system to calculate 3D images under various conditions of spatial resolution. As a small object, we made a blood vessel phantom in which the direction of the vessel was not parallel to either the xy scan-plane or the z-axis perpendicular to the scan-plane. Therefore, when scanning the phantom, non-sharpness must be induced in all axes of the image. To predict the image blurring of the phantom, 3D spatial resolution is essential. The LSF and SSP were measured on our scanner, and two-dimensional (2D) PSF in the scan-plane was derived from the LSF by solving an integral equation. We obtained 3D images by convolving the 3D object-function of the phantom with both 2D PSF and SSP, corresponding to the 3D convolution. Calculated images showed good agreement with scanned images. Our technique of determining 3D blurring offers an accuracy advantage in 3D shape (size) and density measurements of small objects. (author)

  14. New Statistical Method to Analyze Three-Dimensional Landmark Configurations Obtained with Cone-Beam CT: Basic Features and Clinical Application for Rapid Maxillary Expansion

    Energy Technology Data Exchange (ETDEWEB)

    Gamble, Jennifer; Lagravere, Manuel O.; Major, Paul W.; Heo, Giseon [University of Alberta, Edmonton (Canada)

    2012-03-15

    To describe a statistical method of three-dimensional landmark configuration data and apply it to an orthodontic data set comparing two types of rapid maxillary expansion (RME) treatments. Landmark configurations obtained from cone beam CT scans were used to represent patients in two types (please describe what were two types) of RME groups and a control group over four time points. A method using tools from persistent homology and dimensionality reduction is presented and used to identify variability between the subjects. The analysis was in agreement with previous results using conventional methods, which found significant differences between treatment groups and the control, but no distinction between the types of treatment. Additionally, it was found that second molar eruption varied considerably between the subjects, and this has not been evaluated in previous analyses. This method of analysis allows entire configurations to be considered as a whole, and does not require specific inter-landmark distances or angles to be selected. Sources of variability present themselves, without having to be individually sought after. This method is suggested as an additional tool for the analysis of landmark configuration data.

  15. Quantification of Emphysema with a Three-Dimensional Chest CT Scan: Correlation with the Visual Emphysema Scoring on Chest CT, Pulmonary Function Tests and Dyspnea Severity

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hyun Jeong; Hwang, Jung Hwa [Dept. of Radiology, Soonchunhyang University Seoul Hospital, Seoul (Korea, Republic of)

    2011-09-15

    We wanted to prospectively evaluate the correlation between the quantification of emphysema using 3D CT densitometry with the visual emphysema score, pulmonary function tests (PFT) and the dyspnea score in patients with chronic obstructive pulmonary disease (COPD). Non-enhanced chest CT with 3D reconstruction was performed in 28 men with COPD (age 54-88 years). With histogram analysis, the total lung volume, mean lung density and proportion of low attenuation lung volume below predetermined thresholds were measured. The CT parameters were compared with the visual emphysema score, the PFT and the dyspnea score. A low attenuation lung volume below -950 HU was well correlated with the DLco and FEV{sub 1}/FVC. A Low attenuation lung volume below -950 HU and -930 HU was correlated with visual the emphysema score. A low attenuation lung volume below -950 HU was correlated with the dyspnea score, although the correlations between the other CT parameters and the dyspnea score were not significant. Objective quantification of emphysema using 3D CT densitometry was correlated with the visual emphysema score. A low attenuation lung volume below -950 HU was correlated with the DLco, the FEV{sub 1}/FVC and the dyspnea score.

  16. Quantification of Emphysema with a Three-Dimensional Chest CT Scan: Correlation with the Visual Emphysema Scoring on Chest CT, Pulmonary Function Tests and Dyspnea Severity

    International Nuclear Information System (INIS)

    Park, Hyun Jeong; Hwang, Jung Hwa

    2011-01-01

    We wanted to prospectively evaluate the correlation between the quantification of emphysema using 3D CT densitometry with the visual emphysema score, pulmonary function tests (PFT) and the dyspnea score in patients with chronic obstructive pulmonary disease (COPD). Non-enhanced chest CT with 3D reconstruction was performed in 28 men with COPD (age 54-88 years). With histogram analysis, the total lung volume, mean lung density and proportion of low attenuation lung volume below predetermined thresholds were measured. The CT parameters were compared with the visual emphysema score, the PFT and the dyspnea score. A low attenuation lung volume below -950 HU was well correlated with the DLco and FEV 1 /FVC. A Low attenuation lung volume below -950 HU and -930 HU was correlated with visual the emphysema score. A low attenuation lung volume below -950 HU was correlated with the dyspnea score, although the correlations between the other CT parameters and the dyspnea score were not significant. Objective quantification of emphysema using 3D CT densitometry was correlated with the visual emphysema score. A low attenuation lung volume below -950 HU was correlated with the DLco, the FEV 1 /FVC and the dyspnea score.

  17. Three-Dimensional Assessment of Bilateral Symmetry of the Scaphoid: An Anatomic Study

    Directory of Open Access Journals (Sweden)

    Paul W. L. ten Berg

    2015-01-01

    Full Text Available Preoperative 3D CT imaging techniques provide displacement analysis of the distal scaphoid fragment in 3D space, using the matched opposite scaphoid as reference. Its accuracy depends on the presence of anatomical bilateral symmetry, which has not been investigated yet using similar techniques. Our purpose was to investigate symmetry by comparing the relative positions of distal and proximal poles between sides. We used bilateral CT scans of 19 adult healthy volunteers to obtain 3D scaphoid models. Left proximal and distal poles were matched to corresponding mirrored right sides. The left-to-right positional differences between poles were quantified in terms of three translational and three rotational parameters. The mean (SD of ulnar, dorsal, and distal translational differences of distal poles relative to proximal poles was 0.1 (0.6; 0.4 (1.2; 0.2 (0.6 mm and that of palmar rotation, ulnar deviation, and pronation differences was −1.1 (4.9; −1.5 (3.3; 1.0 (3.7°, respectively. These differences did not significantly differ from zero and thus were not biased to left or right side. We proved that, on average, the articular surfaces of scaphoid poles were symmetrically aligned in 3D space. This suggests that the contralateral scaphoid can serve as reference in corrective surgery. No level of evidence is available.

  18. Postoperative three-dimensional CT angiography after cerebral aneurysm clipping with titanium clips: detection with single detector CT. Comparison with intra-arterial digital subtraction angiography

    International Nuclear Information System (INIS)

    Sakuma, I.; Tomura, N.; Kinouchi, H.; Takahashi, S.; Otani, T.; Watarai, J.; Mizoi, K.

    2006-01-01

    AIM: To assess the significance of three-dimensional computed tomography angiography (3D-CTA) in detecting remnant necks after cerebral aneurysm clipping. MATERIALS AND METHODS: A total of 59 patients (77 aneurysms) underwent surgery using titanium clips. Two blinded observers independently evaluated the presence of neck remnants on shaded-surface display (SSD) imaging, volume rendered (VR) imaging, and intra-arterial digital subtraction angiography (IADSA). RESULTS: Mean sensitivity and specificity for detecting neck remnants were 50.0 and 74.2% for SSD imaging, 61.5 and 82.8% for VR imaging, and 92.3 and 92.2% for IADSA, respectively. Receiver operating characteristic (ROC) analysis revealed excellent diagnostic performance for IADSA [mean area under ROC curve (Az)=0.97], and good diagnostic performance for 3D-CTA (Az=0.70 and 0.76 for SSD and VR, respectively). Specificity of VR was better than that SSD (p=0.082), however, there was no significant difference between them. CONCLUSION: Use of 3D-CTA techniques can facilitate postoperative evaluation

  19. A Three-Dimensional Numerical Study of Gas-Particle Flow and Chemical Reactions in Circulating Fluidised Bed Reactors

    DEFF Research Database (Denmark)

    Hansen, Kim Granly

    Three-dimensional Computational Fluid Dynamics (CFD) simulations of Circulating Fluidized Beds (CFB's) have been performed. The computations are performed using a 3D multiphase computational fluid dynamics code with an Eulerian description of both gas and particle phases. The turbulent motion...... implemented in the CFD code FLOTRACS-MP-3D. The decomposition reaction is studied in a 3D representation of a 0.254 m i.d. riser, which has been studied experimentally by Ouyang et al. (1993). Comparison between measured and simulated time-averaged ozone concentration at different elevations in the riser...

  20. A Feasibility Study into the Use of Three-Dimensional Printer Modelling in Acetabular Fracture Surgery

    Directory of Open Access Journals (Sweden)

    A. W. Yu

    2015-01-01

    Full Text Available There are a number of challenges associated with the operative treatment of acetabular fractures. The approach used is often extensive, while operative time and perioperative blood loss can also be significant. With the proliferation of 3D printer technology, we present a fast and economical way to aid the operative planning of complex fractures. We used augmented stereoscopic 3D CT reconstructions to allow for an appreciation of the normal 3D anatomy of the pelvis on the fractured side and to use the models for subsequent intraoperative contouring of pelvic reconstruction plates. This leads to a reduction in the associated soft tissue trauma, reduced intraoperative time and blood loss, minimal handling of the plate, and reduced fluoroscopic screening times. We feel that the use of this technology to customize implants, plates, and the operative procedure to a patient’s unique anatomy can only lead to improved outcomes.

  1. Three-Dimensional Organotypic Co-Culture Model of Intestinal Epithelial Cells and Macrophages to Study "Salmonella Enterica" Colonization Patterns

    Science.gov (United States)

    Ott, Mark; Yang, J; Barilla, J.; Crabbe, A.; Sarker, S. F.; Liu, Y.

    2017-01-01

    Three-dimensional/3-D organotypic models of human intestinal epithelium mimic the differentiated form and function of parental tissues often not exhibited by 2-D monolayers and respond to Salmonella in ways that reflect in vivo infections. To further enhance the physiological relevance of 3-D models to more closely approximate in vivo intestinal microenvironments during infection, we developed and validated a novel 3-D intestinal co-culture model containing multiple epithelial cell types and phagocytic macrophages, and applied to study enteric infection by different Salmonella pathovars.

  2. Three-dimensional ordering of cold ion beams in a storage ring: A molecular-dynamics simulation study

    Energy Technology Data Exchange (ETDEWEB)

    Yuri, Yosuke, E-mail: yuri.yosuke@jaea.go.jp [Takasaki Advanced Radiation Research Institute, Japan Atomic Energy Agency, 1233 Watanuki-machi Takasaki, Gunma 370-1292 Japan (Japan)

    2015-06-29

    Three-dimensional (3D) ordering of a charged-particle beams circulating in a storage ring is systematically studied with a molecular-dynamics simulation code. An ion beam can exhibit a 3D ordered configuration at ultralow temperature as a result of powerful 3D laser cooling. Various unique characteristics of the ordered beams, different from those of crystalline beams, are revealed in detail, such as the single-particle motion in the transverse and longitudinal directions, and the dependence of the tune depression and the Coulomb coupling constant on the operating points.

  3. Study of three-dimensional Rayleigh--Taylor instability in compressible fluids through level set method and parallel computation

    International Nuclear Information System (INIS)

    Li, X.L.

    1993-01-01

    Computation of three-dimensional (3-D) Rayleigh--Taylor instability in compressible fluids is performed on a MIMD computer. A second-order TVD scheme is applied with a fully parallelized algorithm to the 3-D Euler equations. The computational program is implemented for a 3-D study of bubble evolution in the Rayleigh--Taylor instability with varying bubble aspect ratio and for large-scale simulation of a 3-D random fluid interface. The numerical solution is compared with the experimental results by Taylor

  4. Studies on the numerical solution of three-dimensional stationary diffusion equations using the finite element method

    International Nuclear Information System (INIS)

    Franke, H.P.

    1976-05-01

    The finite element method is applied to the solution of the stationary 3D group diffusion equations. For this, a programme system with the name of FEM3D is established which also includes a module for semi-automatic mesh generation. Tetrahedral finite elements are used. The neutron fluxes are described by complete first- or second-order Lagrangian polynomials. General homogeneous boundary conditions are allowed. The studies show that realistic three-dimensional problems can be solved at less expense by iterative methods, in particular so when especially adapted matrix handling and storage schemes are used efficiently. (orig./RW) [de

  5. Human vocal tract resonances and the corresponding mode shapes investigated by three-dimensional finite-element modelling based on CT measurement.

    Science.gov (United States)

    Vampola, Tomáš; Horáček, Jaromír; Laukkanen, Anne-Maria; Švec, Jan G

    2015-04-01

    Resonance frequencies of the vocal tract have traditionally been modelled using one-dimensional models. These cannot accurately represent the events in the frequency region of the formant cluster around 2.5-4.5 kHz, however. Here, the vocal tract resonance frequencies and their mode shapes are studied using a three-dimensional finite element model obtained from computed tomography measurements of a subject phonating on vowel [a:]. Instead of the traditional five, up to eight resonance frequencies of the vocal tract were found below the prominent antiresonance around 4.7 kHz. The three extra resonances were found to correspond to modes which were axially asymmetric and involved the piriform sinuses, valleculae, and transverse vibrations in the oral cavity. The results therefore suggest that the phenomenon of speaker's and singer's formant clustering may be more complex than originally thought.

  6. Three-dimensional conformal radiotherapy by delineations on CT-based simulation in different respiratory phases for the treatment of senile patients with non-small cell lung cancer.

    Science.gov (United States)

    Wang, Weifeng; Yuan, Feng; Wang, Guoping; Lin, Zhiren; Pan, Yanling; Chen, Longhua

    2015-01-01

    This study aimed to evaluate the application of three-dimensional conformal radiotherapy (3D-CRT) for elderly patients with non-small cell lung cancer (NSCLC) based on computed tomography (CT) simulations in different respiratory phases. A total of 64 patients aged >70 years old with NSCLC were treated by 3D-CRT using CT images in different respiratory phases. The gross tumor volumes (GTVs) at the end of inspiration and end of expiration were combined to obtain the total GTV, which was close to the motional range of tumors during respiration, and no additional expansion of the clinical target volume (CTAV) to planning target volume (PTV) (CTAV:PTV) was included during the recording of respiratory movements. Patients were also planned according to the classic 3D-CRT approach. Efficacy, prognostic factors, and side effects were evaluated. Compared with the classic approach, the average PTV was 18.9% lower (median: 17.3%), and the average lung volume receiving a prescribed dose for a tumor was 22.4% lower (median: 20.9%). The 1-, 2-, and 3-year survival rates were 70.6%, 54.9%, and 29.4%, respectively, with an overall tumor response rate of 79.7%. The Karnofsky performance status and N stage were independent prognostic factors, whereas age was not. Without affecting therapeutic effects, CT simulations in different respiratory phases were well-tolerated in elderly patients with NSCLC, could effectively reduce PTV, and could improve the quality of life.

  7. Effects of emotional valence and three-dimensionality of visual stimuli on brain activation: an fMRI study.

    Science.gov (United States)

    Dores, A R; Almeida, I; Barbosa, F; Castelo-Branco, M; Monteiro, L; Reis, M; de Sousa, L; Caldas, A Castro

    2013-01-01

    Examining changes in brain activation linked with emotion-inducing stimuli is essential to the study of emotions. Due to the ecological potential of techniques such as virtual reality (VR), inspection of whether brain activation in response to emotional stimuli can be modulated by the three-dimensional (3D) properties of the images is important. The current study sought to test whether the activation of brain areas involved in the emotional processing of scenarios of different valences can be modulated by 3D. Therefore, the focus was made on the interaction effect between emotion-inducing stimuli of different emotional valences (pleasant, unpleasant and neutral valences) and visualization types (2D, 3D). However, main effects were also analyzed. The effect of emotional valence and visualization types and their interaction were analyzed through a 3 × 2 repeated measures ANOVA. Post-hoc t-tests were performed under a ROI-analysis approach. The results show increased brain activation for the 3D affective-inducing stimuli in comparison with the same stimuli in 2D scenarios, mostly in cortical and subcortical regions that are related to emotional processing, in addition to visual processing regions. This study has the potential of clarify brain mechanisms involved in the processing of emotional stimuli (scenarios' valence) and their interaction with three-dimensionality.

  8. Bioprinting of three dimensional tumor models: a preliminary study using a low cost 3D printer

    Directory of Open Access Journals (Sweden)

    Polley Christian

    2017-09-01

    Full Text Available The deep understanding of cancer and tumor genesis, as well as the development of new therapy strategies still remains one of the emerging challenges in modern medicine. To meet these challenges it seems to be absolutely necessary to overcome the drawbacks of the established 2D in vitro models. Especially the missing microenvironment of the tumor, which means the absence of stroma and immune cells, results in a missing cell-cell and cell-stroma interaction as well as disrupted functional communication pathways. Modern 3D culture systems and 3D printing or rather bioprinting technologies attempt to solve this issue and aim to closely mimic natural tumor microenvironment. In this preliminary work we are going to present the first steps of establishing an artificial 3D tumor model utilising a low cost 3D printer. Therefore the printer had been modified with an open-source syringe pump to become a functional bioprinter using viscosity modulated alginate hydrogel. In the first attempts L929 mouse fibroblasts, which are an integral component of natural stroma, had been incorporated into the hydrogel matrix and printed into scaffolds. Subsequent to the printing process the scaffolds got ionically crosslinked with a 5% w/v aqueous solution of CaCl2 to become mechanically stable. After three days of cultivation viability testing had been performed by utilising FDG staining and PET CT to obtain a volumetric viability measurement. The viability imaging showed vital cells homogeneously distributed in the scaffold and therefore stands as an evidence for a working low cost bioprinting process and a successful first step for the development of an artificial 3D tumor model.

  9. A SAMPLE STUDY ON THE IMPORTANCE AND THE EVALUATION OF THREE DIMENSIONAL EXPRESSION TECHNIQUES IN THE EDUCATION OF PLANTING DESIGN

    Directory of Open Access Journals (Sweden)

    Banu Çiçek Kurdoğlu

    2008-04-01

    Full Text Available :Drafts developed in graphical expression techniques and models formed in abstract manners and gradually becoming concrete are used for the exhibition of the targeted images in the design process, which is also a mental improvement process. Among the biggest difficulty beginner architecture students face is failing to make comments on the products they design in architecture design process; their spatial relationships and express them in two or three-dimensional models. Expression and modelling techniques to be used in this process are very important. In this study, a lesson programme enriched with two and three – dimensional model expression techniques for planting design education, which is of vital significance in landscape architecture departments, was developed and applied. Advantages and disadvantages of the programme were evaluated and some suggestions were offered. Consequently, importance of three dimensional expression techniques and need for them were re-emphasized and the efficiency of the modelling technique used in the study was determined under today’s and Turkey’s conditions.

  10. Developing a methodology for three-dimensional correlation of PET-CT images and whole-mount histopathology in non-small-cell lung cancer.

    Science.gov (United States)

    Dahele, M; Hwang, D; Peressotti, C; Sun, L; Kusano, M; Okhai, S; Darling, G; Yaffe, M; Caldwell, C; Mah, K; Hornby, J; Ehrlich, L; Raphael, S; Tsao, M; Behzadi, A; Weigensberg, C; Ung, Y C

    2008-10-01

    Understanding the three-dimensional (3D) volumetric relationship between imaging and functional or histopathologic heterogeneity of tumours is a key concept in the development of image-guided radiotherapy. Our aim was to develop a methodologic framework to enable the reconstruction of resected lung specimens containing non-small-cell lung cancer (NSCLC), to register the result in 3D with diagnostic imaging, and to import the reconstruction into a radiation treatment planning system. We recruited 12 patients for an investigation of radiology-pathology correlation (RPC) in nsclc. Before resection, imaging by positron emission tomography (PET) or computed tomography (CT) was obtained. Resected specimens were formalin-fixed for 1-24 hours before sectioning at 3-mm to 10-mm intervals. To try to retain the original shape, we embedded the specimens in agar before sectioning. Consecutive sections were laid out for photography and manually adjusted to maintain shape. Following embedding, the tissue blocks underwent whole-mount sectioning (4-mum sections) and staining with hematoxylin and eosin. Large histopathology slides were used to whole-mount entire sections for digitization. The correct sequence was maintained to assist in subsequent reconstruction. Using Photoshop (Adobe Systems Incorporated, San Jose, CA, U.S.A.), contours were placed on the photographic images to represent the external borders of the section and the extent of macroscopic disease. Sections were stacked in sequence and manually oriented in Photoshop. The macroscopic tumour contours were then transferred to MATLAB (The Mathworks, Natick, MA, U.S.A.) and stacked, producing 3D surface renderings of the resected specimen and embedded gross tumour. To evaluate the microscopic extent of disease, customized "tile-based" and commercial confocal panoramic laser scanning (TISSUEscope: Biomedical Photometrics, Waterloo, ON) systems were used to generate digital images of whole-mount histopathology sections

  11. Three dimensional canonical transformations

    International Nuclear Information System (INIS)

    Tegmen, A.

    2010-01-01

    A generic construction of canonical transformations is given in three-dimensional phase spaces on which Nambu bracket is imposed. First, the canonical transformations are defined as based on cannonade transformations. Second, it is shown that determination of the generating functions and the transformation itself for given generating function is possible by solving correspondent Pfaffian differential equations. Generating functions of type are introduced and all of them are listed. Infinitesimal canonical transformations are also discussed as the complementary subject. Finally, it is shown that decomposition of canonical transformations is also possible in three-dimensional phase spaces as in the usual two-dimensional ones.

  12. Accuracy of three-dimensional cone beam computed tomography digital model measurements compared with plaster study casts

    Directory of Open Access Journals (Sweden)

    Shuaib Al Ali

    2017-01-01

    Full Text Available Purpose: The purpose of this study was to assess the accuracy of three-dimensional (3D cone beam computed tomography (CBCT study casts by comparing with direct measurements taken from plaster study casts. Materials and Methods: The dental arches of 30 patient subjects were imaged with a Kodak 9300 3D CBCT devise; Anatomodels were created and in vivo 5 imaging software was used to measure 10 dental arch variables which were compared to measurements of plaster study casts. Results: Three of the 10 variables, i.e., overbite, maxillary intermolar width, and arch length, were found significantly smaller (P < 0.05 using the Anatomodels following nonparametric Wilcoxon signed-rank testing. None of the differences found in the study averaged <0.5 mm. Conclusions: 3D CBCT imaging provided clinically acceptable accuracy for dental arch analysis. 3D CBCT imaging tended to underestimate the actual measurement compared to plaster study casts.

  13. Confidence in Assessment of Lumbar Spondylolysis Using Three-Dimensional Volumetric T2-Weighted MRI Compared With Limited Field of View, Decreased-Dose CT.

    Science.gov (United States)

    Delavan, Joshua Adam; Stence, Nicholas V; Mirsky, David M; Gralla, Jane; Fadell, Michael F

    2016-07-01

    Limited z-axis-coverage computed tomography (CT) to evaluate for pediatric lumbar spondylolysis, altering the technique such that the dose to the patient is comparable or lower than radiographs, is currently used at our institution. The objective of the study was to determine whether volumetric 3-dimensional fast spin echo magnetic resonance imaging (3D MRI) can provide equal or greater diagnostic accuracy compared with limited CT in the diagnosis of pediatric lumbar spondylolysis without ionizing radiation. Volumetric 3D MRI can provide equal or greater diagnostic accuracy compared with low-dose CT for pediatric lumbar spondylolysis without ionizing radiation. Clinical review. Level 2. Three pediatric neuroradiologists evaluated 2-dimensional (2D) MRI, 2D + 3D MRI, and limited CT examinations in 42 pediatric patients who obtained imaging for low back pain and suspected spondylolysis. As there is no gold standard for the diagnosis of spondylolysis besides surgery, interobserver agreement and degree of confidence were compared to determine which modality is preferable. Decreased-dose CT provided a greater level of agreement than 2D MRI and 2D + 3D MRI. The kappa for rater agreement with 2D MRI, 2D + 3D MRI, and CT was 0.19, 0.32, and 1.0, respectively. All raters agreed in 31%, 40%, and 100% of cases with 2D MRI, 2D + 3D MRI, and CT. Lack of confidence was significantly lower with CT (0%) than with 2D MRI (30%) and 2D + 3D MRI (25%). For diagnosing spondylolysis, radiologist agreement and confidence trended toward improvement with the addition of a volumetric 3D MRI sequence to standard 2D MRI sequences compared with 2D MRI alone; however, agreement and confidence remain significantly greater using decreased-dose CT when compared with either MRI acquisition. Decreased-dose CT of the lumbar spine remains the optimal examination to confirm a high suspicion of spondylolysis, with dose essentially equivalent to radiographs. If clinical symptoms are not classic for

  14. A simple, rapid method to isolate salt glands for three-dimensional visualization, fluorescence imaging and cytological studies

    Directory of Open Access Journals (Sweden)

    Lim Tit-Meng

    2010-10-01

    Full Text Available Abstract Background Some plants inhabiting saline environment remove salts via the salt glands embedded in the epidermal tissues. Cytological studies of salt glands will provide valuable information to our understanding of the secretory process. Previous studies on salt gland histology relied mainly on two-dimensional microscopic observations of microtome sections. Optical sectioning properties of confocal laser scanning microscope offer alternative approach for obtaining three-dimensional structural information of salt glands. Difficulty in light penetration through intact leaves and interference from neighbouring leaf cells, however, impede the acquiring of good optical salt gland sections and limit its applications in salt gland imaging. Freeing the glands from adjacent leaf tissues will allow better manipulations for three-dimensional imaging through confocal laser scanning microscopy. Results Here, we present a simple and fast method for the isolation of individual salt glands released from the interference of neighbouring cells. About 100-200 salt glands could be isolated from just one cm2 of Avicennia officinalis leaf within hours and microscopic visualization of isolated salt glands was made possible within a day. Using these isolated glands, confocal laser scanning microscopic techniques could be applied and better resolution salt gland images could be achieved. By making use of their intrinsic fluorescent properties, optical sections of the gland cells could be acquired without the use of fluorescent probes and the corresponding three-dimensional images constructed. Useful cytological information of the salt gland cells could also be obtained through the applications of fluorescent dyes (e.g., LysoTracker® Red, FM®4-64, Texas Red®. Conclusions The study of salt glands directly at the glandular level are made possible with the successful isolation of these specialized structures. Preparation of materials for subsequent microscopic

  15. Association Study between BDNF Gene Polymorphisms and Autism by Three-Dimensional Gel-Based Microarray

    Directory of Open Access Journals (Sweden)

    Zuhong Lu

    2009-06-01

    Full Text Available Single nucleotide polymorphisms (SNPs are important markers which can be used in association studies searching for susceptible genes of complex diseases. High-throughput methods are needed for SNP genotyping in a large number of samples. In this study, we applied polyacrylamide gel-based microarray combined with dual-color hybridization for association study of four BDNF polymorphisms with autism. All the SNPs in both patients and controls could be analyzed quickly and correctly. Among four SNPs, only C270T polymorphism showed significant differences in the frequency of the allele (χ2 = 7.809, p = 0.005 and genotype (χ2 = 7.800, p = 0.020. In the haplotype association analysis, there was significant difference in global haplotype distribution between the groups (χ2 = 28.19,p = 3.44e-005. We suggest that BDNF has a possible role in the pathogenesis of autism. The study also show that the polyacrylamide gel-based microarray combined with dual-color hybridization is a rapid, simple and high-throughput method for SNPs genotyping, and can be used for association study of susceptible gene with disorders in large samples.

  16. Three-Dimensional Model Test Study of a CUBIPOD Armoured Roundhead

    DEFF Research Database (Denmark)

    Burcharth, Hans F.; Andersen, Thomas Lykke; Aldama, J. M. Urrutia

    ‐crested wave tests were performed as well. One objective of the tests was to compare the stability of CUBIPOD armoured roundheads to the stability of cube armoured roundheads. This could be done by choosing a model test setup identical to that previous used in a study of the stability of a cube armoured......The present report presents results from a three‐dimensional model test study carried out at Aalborg University in the period September 2008 - December 2008. The model tests were carried out to study the stability of a CUBIPOD armoured roundhead under short‐crested wave attack. Few long...... roundhead for the Punta Langosteira breakwater at La Coruna. To have a direct comparison some of the new test series were reproduced with cubes also. This was done with identical steering signals send to the paddles....

  17. Experimental and clinical studies of fast three-dimensional MR imaging of the heart

    International Nuclear Information System (INIS)

    Sato, Shuhei

    1999-01-01

    MRI has been utilized since its inception to study the anatomy and physiology of the heart. However, the sensitivity of MRI to motion has always posed a major challenge in imaging this organ. The purpose of this study was to develop a 3D MP-RAGE technique for the heart, and to apply it clinically. In the experimental study, data acquisition timing was discussed by normal volunteers. Changes in magnetization recovery time affected imaging contrast very little in the phantom study. Fourteen adults and 21 children were examined. In the adults, MP-RAGE images were rated as high in quality in the visual estimation. In the quantitative estimation, the images provided almost the same anatomical information as those of cine MRI. In the children, MP-RAGE was useful for cases of partial anomalous pulmonary venous drainage, particularly in the evaluation of abnormal pulmonary veins. The 3D MP-RAGE technique was useful in imaging the heart because it was possible to obtain continuous views in the same cardiac cycle and to reconstruct views from any direction after the examination. (author)

  18. Experimental and clinical studies of fast three-dimensional MR imaging of the heart

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Shuhei [Okayama Univ. (Japan). School of Medicine

    1999-07-01

    MRI has been utilized since its inception to study the anatomy and physiology of the heart. However, the sensitivity of MRI to motion has always posed a major challenge in imaging this organ. The purpose of this study was to develop a 3D MP-RAGE technique for the heart, and to apply it clinically. In the experimental study, data acquisition timing was discussed by normal volunteers. Changes in magnetization recovery time affected imaging contrast very little in the phantom study. Fourteen adults and 21 children were examined. In the adults, MP-RAGE images were rated as high in quality in the visual estimation. In the quantitative estimation, the images provided almost the same anatomical information as those of cine MRI. In the children, MP-RAGE was useful for cases of partial anomalous pulmonary venous drainage, particularly in the evaluation of abnormal pulmonary veins. The 3D MP-RAGE technique was useful in imaging the heart because it was possible to obtain continuous views in the same cardiac cycle and to reconstruct views from any direction after the examination. (author)

  19. Three-dimensional reconstruction used in the diagnosis and treatment of depressed fracture of skull

    International Nuclear Information System (INIS)

    Li Liang; Luo Zhikun; Lin Xiaohui; Liu Shuyi; Chen Xu; Liu Chenghui

    2005-01-01

    Objective: To evaluate three-dimensional reconstruction used in the diagnosis and management of depressed fracture of skull. Methods: The images of CT scan and three-dimensional reconstruction in 23 patients with depressed fracture of skull were studied. The clinical treatment was guided by the images. Results: The fracture site and depth in all 23 cases were well demonstrated in the imaging of three-dimensional reconstruction, which successfully guided the clinical management in every case. Conclusion: Three-dimensional reconstruction is a valuable modality for the diagnosis and management of depressed fracture of skull. (authors)

  20. Three dimensional atom probe study of Ni-base alloy/low alloy steel dissimilar metal weld interfaces

    International Nuclear Information System (INIS)

    Choi, Kyoung Joon; Shin, Sang Hun; Kim, Jong Jin; Jung, Ju Ang; Kim, Ji Hyun

    2012-01-01

    Three dimensional atom probe tomography (3D APT) is applied to characterize the dissimilar metal joint which was welded between the Ni-based alloy, Alloy 690 and the low alloy steel, A533 Gr. B, with Alloy 152 filler metal. While there is some difficulty in preparing the specimen for the analysis, the 3D APT has a truly quantitative analytical capability to characterize nanometer scale particles in metallic materials, thus its application to the microstructural analysis in multicomponent metallic materials provides critical information on the mechanism of nanoscale microstructural evolution. In this study, the procedure for 3D APT specimen preparation was established, and those for dissimilar metal weld interface were prepared near the fusion boundary by a focused ion beam. The result of the analysis in this study showed the precipitation of chromium carbides near the fusion boundary between A533 Gr. B and Alloy 152.

  1. Three dimensional atom probe study of Ni-base alloy/low alloy steel dissimilar metal weld interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Kyoung Joon; Shin, Sang Hun; Kim, Jong Jin; Jung, Ju Ang; Kim, Ji Hyun [Interdisciplinary School of Green Energy, Ulsan National Institute of Science and Technology, Ulsan (Korea, Republic of)

    2012-08-15

    Three dimensional atom probe tomography (3D APT) is applied to characterize the dissimilar metal joint which was welded between the Ni-based alloy, Alloy 690 and the low alloy steel, A533 Gr. B, with Alloy 152 filler metal. While there is some difficulty in preparing the specimen for the analysis, the 3D APT has a truly quantitative analytical capability to characterize nanometer scale particles in metallic materials, thus its application to the microstructural analysis in multicomponent metallic materials provides critical information on the mechanism of nanoscale microstructural evolution. In this study, the procedure for 3D APT specimen preparation was established, and those for dissimilar metal weld interface were prepared near the fusion boundary by a focused ion beam. The result of the analysis in this study showed the precipitation of chromium carbides near the fusion boundary between A533 Gr. B and Alloy 152.

  2. Study on the Effect of the Three-Dimensional Electrode in Degradation of Methylene Blue by Lithium Modified Rectorite

    Directory of Open Access Journals (Sweden)

    Jian Huang

    2016-01-01

    Full Text Available This study presents the electrochemical degradation of methylene blue (MB wastewater in a synthetic solution using three-dimensional particle electrodes. The novel particle electrodes were fabricated in this work using the lithium modified rectorite (Li-REC. The adsorption property of the fabricated particle electrodes was studied in a series of experiments. The optimum electrochemical operating conditions of plate distance, cell voltage, and concentration of electrolyte were 2 cm, 9 V, and 0.06 mol L−1, respectively. It was also found that microwave irradiation can effectively improve the adsorption property and electrical property of the fabricated electrodes. In addition, the scanning electron microscope (SEM of the fabricated electrodes was investigated. The experimental results revealed the order of adsorption property and electrical property of the fabricated electrodes. So, fabricated electrodes are not only of low cost and mass produced, but also efficient to achieve decolorization of MB solution.

  3. Three-dimensional study of the pressure field and advantages of hemispherical crucible in silicon Czochralski crystal growth

    Energy Technology Data Exchange (ETDEWEB)

    Mokhtari, F. [LTSE Laboratory, University of Science and Technol., USTHB BP 32 Elalia, Babezzouar, Algiers (Algeria); University Mouloud Mammeri, Tizi Ouzou (Algeria); Merah, A. [University M' hammed Bougara, Boumerdes (Algeria); Zizi, M. [LTSE Laboratory, University of Science and Technol., USTHB BP 32 Elalia, Babezzouar, Algiers (Algeria); Hanchi, S. [UER Mecanique/ E.M.P B.P 17 Bordj El Bahri, Algiers (Algeria); Alemany, A. [Laboratoire EPM, CNRS, Grenoble (France); Bouabdallah, A.

    2010-06-15

    The effects of several growth parameters in cylindrical and spherical Czochralski crystal process are studied numerically and particularly, we focus on the influence of the pressure field. We present a set of three-dimensional computational simulations using the finite volume package Fluent in two different geometries, a new geometry as cylindro-spherical and the traditional configuration as cylindro-cylindrical. We found that the evolution of pressure which is has not been studied before; this important function is strongly related to the vorticity in the bulk flow, the free surface and the growth interface. It seems that the pressure is more sensitive to the breaking of symmetry than the other properties that characterize the crystal growth as temperature or velocity fields. (copyright 2010 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  4. Three-dimensional fluid-structure interaction case study on cubical fluid cavity with flexible bottom

    Science.gov (United States)

    Ghelardi, Stefano; Rizzo, Cesare; Villa, Diego

    2017-12-01

    In this paper, we report our study on a numerical fluid-structure interaction problem originally presented by Mok et al. (2001) in two dimensions and later studied in three dimensions by Valdés Vazquez (2007), Lombardi (2012), and Trimarchi (2012). We focus on a 3D test case in which we evaluated the sensitivity of several input parameters on the fluid and structural results. In particular, this analysis provides a starting point from which we can look deeper into specific aspects of these simulations and analyze more realistic cases, e.g., in sails design. In this study, using the commercial software ADINA™, we addressed a well-known unsteadiness problem comprising a square box representing the fluid domain with a flexible bottom modeled with structural shell elements. We compared data from previously published work whose authors used the same numerical approach, i.e., a partitioned approach coupling a finite volume solver (for the fluid domain) and a finite element solver (for the solid domain). Specifically, we established several benchmarks and made comparisons with respect to fluid and solid meshes, structural element types, and structural damping, as well as solution algorithms. Moreover, we compared our method with a monolithic finite element solution method. Our comparisons of new and old results provide an outline of best practices for such simulations.

  5. Intraoperative application of geometric three-dimensional mitral valve assessment package: a feasibility study.

    Science.gov (United States)

    Mahmood, Feroze; Karthik, Swaminathan; Subramaniam, Balachundhar; Panzica, Peter J; Mitchell, John; Lerner, Adam B; Jervis, Karinne; Maslow, Andrew D

    2008-04-01

    To study the feasibility of using 3-dimensional (3D) echocardiography in the operating room for mitral valve repair or replacement surgery. To perform geometric analysis of the mitral valve before and after repair. Prospective observational study. Academic, tertiary care hospital. Consecutive patients scheduled for mitral valve surgery. Intraoperative reconstruction of 3D images of the mitral valve. One hundred and two patients had 3D analysis of their mitral valve. Successful image reconstruction was performed in 93 patients-8 patients had arrhythmias or a dilated mitral valve annulus resulting in significant artifacts. Time from acquisition to reconstruction and analysis was less than 5 minutes. Surgeon identification of mitral valve anatomy was 100% accurate. The study confirms the feasibility of performing intraoperative 3D reconstruction of the mitral valve. This data can be used for confirmation and communication of 2-dimensional data to the surgeons by obtaining a surgical view of the mitral valve. The incorporation of color-flow Doppler into these 3D images helps in identification of the commissural or perivalvular location of regurgitant orifice. With improvements in the processing power of the current generation of echocardiography equipment, it is possible to quickly acquire, reconstruct, and manipulate images to help with timely diagnosis and surgical planning.

  6. [Studies of three-dimensional cardiac late gadolinium enhancement MRI at 3.0 Tesla].

    Science.gov (United States)

    Ishimoto, Takeshi; Ishihara, Masaru; Ikeda, Takayuki; Kawakami, Momoe

    2008-12-20

    Cardiac late Gadolinium enhancement MR imaging has been shown to allow assessment of myocardial viability in patients with ischemic heart disease. The current standard approach is a 3D inversion recovery sequence at 1.5 Tesla. The aims of this study were to evaluate the technique feasibility and clinical utility of MR viability imaging at 3.0 Tesla in patients with myocardial infarction and cardiomyopathy. In phantom and volunteer studies, the inversion time required to suppress the signal of interests and tissues was prolonged at 3.0 Tesla. In the clinical study, the average inversion time to suppress the signal of myocardium at 3.0 Tesla with respect to MR viability imaging at 1.5 Tesla was at 15 min after the administration of contrast agent (304.0+/-29.2 at 3.0 Tesla vs. 283.9+/-20.9 at 1.5 Tesla). The contrast between infarction and viable myocardium was equal at both field strengths (4.06+/-1.30 at 3.0 Tesla vs. 4.42+/-1.85 at 1.5 Tesla). Even at this early stage, MR viability imaging at 3.0 Tesla provides high quality images in patients with myocardial infarction. The inversion time is significantly prolonged at 3.0 Tesla. The contrast between infarction and viable myocardium at 3.0 Tesla are equal to 1.5 Tesla. Further investigation is needed for this technical improvement, for clinical evaluation, and for limitations.

  7. Stability Estimates for a Twisted Rod Under Terminal Loads: A Three-dimensional Study

    KAUST Repository

    Majumdar, Apala

    2012-03-01

    The stability of an inextensible unshearable elastic rod with quadratic strain energy density subject to end loads is considered. We study the second variation of the corresponding rod-energy, making a distinction between in-plane and out-of-plane perturbations and isotropic and anisotropic cross-sections, respectively. In all cases, we demonstrate that the naturally straight state is a local energy minimizer in parameter regimes specified by material constants. These stability results are also accompanied by instability results in parameter regimes defined in terms of material constants. © 2012 Springer Science+Business Media B.V.

  8. Three-dimensional studies of mixing and stratification in containments cooled by internal condensers

    Energy Technology Data Exchange (ETDEWEB)

    Putz, F.; Dury, T. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    2001-07-01

    Within the scope of the fourth EU Framework Programme IPSS project, two passive containment cooling systems, the so-called Building Condenser (BC, under an additional bilateral contract between PSI and Siemens) and Plate Condenser (PC), have been studied at the PSI PANDA facility. From the two tests series, tests BC4 and PC1 have been selected for analysis with the code GOTHIC 6.0. Particular phenomena which are of importance with regard to the condensers operating conditions (mixing/stratification of non-condensable gases, such as air and helium) have been analysed. The GOTHIC simulations have been complemented by CFD calculations with CFX-4. (author)

  9. Stability Estimates for a Twisted Rod Under Terminal Loads: A Three-dimensional Study

    KAUST Repository

    Majumdar, Apala; Prior, Christopher; Goriely, Alain

    2012-01-01

    The stability of an inextensible unshearable elastic rod with quadratic strain energy density subject to end loads is considered. We study the second variation of the corresponding rod-energy, making a distinction between in-plane and out-of-plane perturbations and isotropic and anisotropic cross-sections, respectively. In all cases, we demonstrate that the naturally straight state is a local energy minimizer in parameter regimes specified by material constants. These stability results are also accompanied by instability results in parameter regimes defined in terms of material constants. © 2012 Springer Science+Business Media B.V.

  10. Three-dimensional studies of mixing and stratification in containments cooled by internal condensers

    International Nuclear Information System (INIS)

    Putz, F.; Dury, T.

    2001-01-01

    Within the scope of the fourth EU Framework Programme IPSS project, two passive containment cooling systems, the so-called Building Condenser (BC, under an additional bilateral contract between PSI and Siemens) and Plate Condenser (PC), have been studied at the PSI PANDA facility. From the two tests series, tests BC4 and PC1 have been selected for analysis with the code GOTHIC 6.0. Particular phenomena which are of importance with regard to the condensers operating conditions (mixing/stratification of non-condensable gases, such as air and helium) have been analysed. The GOTHIC simulations have been complemented by CFD calculations with CFX-4. (author)

  11. Study of Three-dimensional Magnetic Structure and the Successive Eruptive Nature of Active Region 12371

    Science.gov (United States)

    Vemareddy, P.; Demóulin, P.

    2018-04-01

    We study the magnetic structure of a successively erupting sigmoid in active region 12371 by modeling the quasi-static coronal field evolution with nonlinear force-free field (NLFFF) equilibria. Helioseismic and Magnetic Imager/Solar Dynamic Observatory vector magnetograms are used as input to the NLFFF model. In all eruption events, the modeled structure resembles the observed pre-eruptive coronal sigmoid and the NLFFF core field is a combination of double inverse-J-shaped and inverse-S field lines with dips touching the photosphere. Such field lines are formed by the flux cancellation reconnection of opposite-J field lines at bald-patch locations, which in turn implies the formation of a weakly twisted flux-rope (FR) from large-scale sheared arcade field lines. Later on, this FR undergoes coronal tether-cutting reconnection until a coronal mass ejection is triggered. The modeled structure captured these major features of sigmoid-to-arcade-to-sigmoid transformation, which is reoccuring under continuous photospheric flux motions. Calculations of the field line twist reveal a fractional increase followed by a decrease of the number of pixels having a range of twist. This traces the buildup process of a twisted core field by slow photospheric motions and the relaxation after eruption, respectively. Our study infers that the large eruptivity of this AR is due to a steep decrease of the background coronal field meeting the torus instability criteria at a low height (≈40 Mm) in contrast to noneruptive ARs.

  12. Magnetohydrodynamic study for three-dimensional instability of the Petschek type magnetic reconnection

    International Nuclear Information System (INIS)

    Shimizu, T.; Kondoh, K.

    2013-01-01

    The 3D instability of the spontaneous fast magnetic reconnection process is studied with magnetohydrodynamics (MHD) simulations, where the 2D model of the spontaneous fast magnetic reconnection is destabilized in three dimension. As well known in many 2D numerical MHD studies, when a 1D current sheet is destabilized with the current-driven anomalous resistivity, the 2D Petschek type fast magnetic reconnection is established. This paper shows that the 2D Petschek type fast magnetic reconnection can be destabilized in three dimension by an initial resistive disturbance which includes a weak fluctuation in the sheet current direction, i.e., along the magnetic neutral line. The resulting 3D fast magnetic reconnection finally becomes intermittent and random through a 3D instability. In addition, it is also shown that the 3D instability is suppressed by the uniform resistivity. It suggests that the 3D instability is caused in the Petschek-type reconnection process which is characterized by a strongly localized magnetic diffusion region and the slow shock acceleration of the plasma jets and is suppressed in the Sweet-Parker type reconnection process

  13. Three-dimensional studies of intergranular carbides in austenitic stainless steel.

    Science.gov (United States)

    Ochi, Minoru; Kawano, Rika; Maeda, Takuya; Sato, Yukio; Teranishi, Ryo; Hara, Toru; Kikuchi, Masao; Kaneko, Kenji

    2017-04-01

    A large number of morphological studies of intergranular carbides in steels have always been carried out in two dimensions without considering their dispersion manners. In this article, focused ion beam serial-sectioning tomography was carried out to study the correlation among the grain boundary characteristics, the morphologies and the dispersions of intergranular carbides in 347 austenitic stainless steel. More than hundred intergranular carbides were characterized in three dimensions and finally classified into three different types, two types of carbides probably semi-coherent to one of the neighboring grains with plate-type morphology, and one type of carbides incoherent to both grains with rod-type morphology. In addition, the rod-type carbide was found as the largest number of carbides among three types. Since large numbers of defects, such as misfit dislocations, may be present at the grain boundaries, which can be ideal nucleation sites for intergranular rod-type carbide precipitation. © The Author 2016. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved.For permissions, please e-mail: journals.permissions@oup.com.

  14. Linear and nonlinear studies of velocity shear driven three dimensional electron-magnetohydrodynamics instability

    International Nuclear Information System (INIS)

    Gaur, Gurudatt; Das, Amita

    2012-01-01

    The study of electron velocity shear driven instability in electron magnetohydrodynamics (EMHD) regime in three dimensions has been carried out. It is well known that the instability is non-local in the plane defined by the flow direction and that of the shear, which is the usual Kelvin-Helmholtz mode, often termed as the sausage mode in the context of EMHD. On the other hand, a local instability with perturbations in the plane defined by the shear and the magnetic field direction exists which is termed as kink mode. The interplay of these two modes for simple sheared flow case as well as that when an external magnetic field exists has been studied extensively in the present manuscript in both linear and nonlinear regimes. Finally, these instability processes have been investigated for the exact 2D dipole solutions of EMHD equations [M. B. Isichenko and A. N. Marnachev, Sov. Phys. JETP 66, 702 (1987)] for which the electron flow velocity is sheared. It has been shown that dipoles are very robust and stable against the sausage mode as the unstable wavelengths are typically longer than the dipole size. However, we observe that they do get destabilized by the local kink mode.

  15. Three-Dimensional Blood-Brain Barrier Model for in vitro Studies of Neurovascular Pathology

    Science.gov (United States)

    Cho, Hansang; Seo, Ji Hae; Wong, Keith H. K.; Terasaki, Yasukazu; Park, Joseph; Bong, Kiwan; Arai, Ken; Lo, Eng H.; Irimia, Daniel

    2015-10-01

    Blood-brain barrier (BBB) pathology leads to neurovascular disorders and is an important target for therapies. However, the study of BBB pathology is difficult in the absence of models that are simple and relevant. In vivo animal models are highly relevant, however they are hampered by complex, multi-cellular interactions that are difficult to decouple. In vitro models of BBB are simpler, however they have limited functionality and relevance to disease processes. To address these limitations, we developed a 3-dimensional (3D) model of BBB on a microfluidic platform. We verified the tightness of the BBB by showing its ability to reduce the leakage of dyes and to block the transmigration of immune cells towards chemoattractants. Moreover, we verified the localization at endothelial cell boundaries of ZO-1 and VE-Cadherin, two components of tight and adherens junctions. To validate the functionality of the BBB model, we probed its disruption by neuro-inflammation mediators and ischemic conditions and measured the protective function of antioxidant and ROCK-inhibitor treatments. Overall, our 3D BBB model provides a robust platform, adequate for detailed functional studies of BBB and for the screening of BBB-targeting drugs in neurological diseases.

  16. A numerical study of three-dimensional bubble merger in the Rayleigh endash Taylor instability

    International Nuclear Information System (INIS)

    Li, X.L.

    1996-01-01

    The Rayleigh endash Taylor instability arises when a heavy fluid adjacent to a light fluid is accelerated in a direction against the density gradient. Under this unstable configuration, a perturbation mode of small amplitude grows into bubbles of the light fluid and spikes of the heavy fluid. Taylor discovered the steady state motion with constant velocity for a single bubble or periodic bubbles in the Rayleigh endash Taylor instability. Read and Youngs studied the motion of a randomly perturbed fluid interface in the Rayleigh endash Taylor instability. They reported constant acceleration for the overall bubble envelope. Bubble merger is believed to cause the transition from constant velocity to constant acceleration. In this paper, we present a numerical study of this important physical phenomenon. It analyzes the physical process of bubble merger and the relationship between the horizontal bubble expansion and the vertical interface acceleration. A dynamic bubble velocity, beyond Taylor close-quote s steady state value, is observed during the merger process. It is believed that this velocity is due to the superposition of the bubble velocity with a secondary subharmonic unstable mode. The numerical results are compared with experiments. copyright 1996 American Institute of Physics

  17. A simple three-dimensional-focusing, continuous-flow mixer for the study of fast protein dynamics.

    Science.gov (United States)

    Burke, Kelly S; Parul, Dzmitry; Reddish, Michael J; Dyer, R Brian

    2013-08-07

    We present a simple, yet flexible microfluidic mixer with a demonstrated mixing time as short as 80 μs that is widely accessible because it is made of commercially available parts. To simplify the study of fast protein dynamics, we have developed an inexpensive continuous-flow microfluidic mixer, requiring no specialized equipment or techniques. The mixer uses three-dimensional, hydrodynamic focusing of a protein sample stream by a surrounding sheath solution to achieve rapid diffusional mixing between the sample and sheath. Mixing initiates the reaction of interest. Reactions can be spatially observed by fluorescence or absorbance spectroscopy. We characterized the pixel-to-time calibration and diffusional mixing experimentally. We achieved a mixing time as short as 80 μs. We studied the kinetics of horse apomyoglobin (apoMb) unfolding from the intermediate (I) state to its completely unfolded (U) state, induced by a pH jump from the initial pH of 4.5 in the sample stream to a final pH of 2.0 in the sheath solution. The reaction time was probed using the fluorescence of 1-anilinonaphthalene-8-sulfonate (1,8-ANS) bound to the folded protein. We observed unfolding of apoMb within 760 μs, without populating additional intermediate states under these conditions. We also studied the reaction kinetics of the conversion of pyruvate to lactate catalyzed by lactate dehydrogenase using the intrinsic tryptophan emission of the enzyme. We observe sub-millisecond kinetics that we attribute to Michaelis complex formation and loop domain closure. These results demonstrate the utility of the three-dimensional focusing mixer for biophysical studies of protein dynamics.

  18. Three-dimensional stereophotogrammetric analysis of 50 smiles: A study of dento-facial proportions.

    Science.gov (United States)

    Ceinos, R; Lupi, L; Tellier, A; Bertrand, M F

    2017-11-12

    The purpose of this study was to analyze 50 smiles using 3D stereophotogrammetry (3D-spg)-based facial reconstruction, to calculate ratios involving measurements of the distances between dental and facial landmarks and to compare these ratios with the golden ratio φ (1.618). Fifty subjects with no obvious malocclusion participated in this study. For each subject, 4 photographs were acquired using the LifeViz Mini™, an absolute calibration 3D-spg system. Facial and dental landmarks (based on Farkas' definitions) were fixed, and 8 distances were measured. Four ratios were then calculated and compared with the value of 1.618. The ratio "incisal edge of the maxillary central incisor-lower border of the chin/subnasal point-incisal edge of the maxillary central incisor" (IE-Me/SN-IE) was 1.693 ± 0.190, the ratio "right endocanthion-left endocanthion/right exocanthion-right endocanthion" was 1.582 ± 0.173, the ratio "incisal edge of the maxillary central incisor-distal edge of the right canine/distal edge of the right canine-right labial commissure" was 1.670 ± 0.355, and the ratio "right labial commissure-left labial commissure/distal edge of the right canine-distal edge of the left canine" was 1.602 ± 0.136. In contrast, the vertical ratio IE-Me/SN-IE significantly differed from the golden ratio (1 sample t test, P = .009). This study revealed that the observed ratios were surprisingly close to the golden ratio. Only the vertical ratio differed from the golden ratio, whereas the horizontal ratios appear to be adequately approximated by φ. If the distances from reference points of the face to teeth within a harmonious smile exhibited recurring esthetic proportions, knowledge of such ratios would provide an additional tool for the elaboration of esthetic treatment plans. In addition, this knowledge could provide guidance when planning tooth positions and dental proportions by encouraging consideration of the global nature of the oro

  19. Study on improved procedure for determination of three dimensional distributions of the initial rock stresses. 2

    International Nuclear Information System (INIS)

    Mizuta, Yoshiaki

    2003-02-01

    In the fiscal year of 2002, our committee achieved the following work items during the contract period, from August 28th, 2002 to February 7th, 2003. Confirm mutual understanding with respect to the geological/geometrical data provided from Tono Geoscience Center and exchange procedure for taking those into each numerical models. The numerical models by finite element Method and Finite Difference Method were built taking strata data into account. A problem accompanying to back analysis for inhomogeneous modeling was brought up. A new 3D Boundary Element Method Code in which integrations to calculate the influence coefficients are carried out analytically and thus, the solutions with high accuracy can be given faster. Three examples of determination procedures, wide region model by FEM, small region model by FEM and intermediate region model by FDM were introduced. This is the report as the results of the studies mentioned above. (author)

  20. A Study of the transport of three dimensional medical images to remote institutions for telediagnosis

    International Nuclear Information System (INIS)

    Hayashi, Takashi; Takahashi, Katsuhiko; Kaneko, Rumi; Yonezawa, Kazuya; Iwai, Mitsuhiro; Takeda, Satoshi; Tateishi, Toshiki; Ogasawara, Yoko; Hanada, Akiko

    2011-01-01

    Using a 3D-imaging-create-function server and network services by internet protocol-virtual private network (IP-VPN), we began to deliver 3D images to the remote institution. An indication trial of the primary image, a rotary trial of a 3D image, and a reproducibility trial were studied in order to examine the practicality of using the system in a real network between Hakodate and Sapporo (communication distance of about 150 km). In these trials, basic data (time and receiving data volume) were measured for every variation of QF (quality factor) or monitor resolution. Analyzing the results of the system using a 3D image delivery server of our hospital with variations in the setting of QF and monitor resolutions, we concluded that this system has practicality in the remote interpretation-of-radiogram work, even if the access point of the region has a line speed of 6 Mbps. (author)

  1. Numerical Study of Three Dimensional Effects in Longitudinal Space-Charge Impedance

    Energy Technology Data Exchange (ETDEWEB)

    Halavanau, A. [NICADD, DeKalb; Piot, P. [NICADD, DeKalb

    2015-06-01

    Longitudinal space-charge (LSC) effects are generally considered as detrimental in free-electron lasers as they can seed instabilities. Such “microbunching instabilities” were recently shown to be potentially useful to support the generation of broadband coherent radiation pulses [1, 2]. Therefore there has been an increasing interest in devising accelerator beamlines capable of sustaining this LSC instability as a mechanism to produce a coherent light source. To date most of these studies have been carried out with a one-dimensional impedance model for the LSC. In this paper we use a N-body “Barnes-Hut” algorithm [3] to simulate the 3D space charge force in the beam combined with elegant [4] and explore the limitation of the 1D model often used

  2. Study of the cell activity in three-dimensional cell culture by using Raman spectroscopy

    Science.gov (United States)

    Arunngam, Pakajiraporn; Mahardika, Anggara; Hiroko, Matsuyoshi; Andriana, Bibin Bintang; Tabata, Yasuhiko; Sato, Hidetoshi

    2018-02-01

    The purpose of this study is to develop a estimation technique of local cell activity in cultured 3D cell aggregate with gelatin hydrogel microspheres by using Raman spectroscopy. It is an invaluable technique allowing real-time, nondestructive, and invasive measurement. Cells in body generally exist in 3D structure, which physiological cell-cell interaction enhances cell survival and biological functions. Although a 3D cell aggregate is a good model of the cells in living tissues, it was difficult to estimate their physiological conditions because there is no effective technique to make observation of intact cells in the 3D structure. In this study, cell aggregates were formed by MC3T-E1 (pre-osteoblast) cells and gelatin hydrogel microspheres. In appropriate condition MC3T-E1 cells can differentiate into osteoblast. We assume that the activity of the cell would be different according to the location in the aggregate because the cells near the surface of the aggregate have more access to oxygen and nutrient. Raman imaging technique was applied to measure 3D image of the aggregate. The concentration of the hydroxyapatite (HA) is generated by osteoblast was estimated with a strong band at 950-970 cm-1 which assigned to PO43- in HA. It reflects an activity of the specific site in the cell aggregate. The cell density in this specific site was analyzed by multivariate analysis of the 3D Raman image. Hence, the ratio between intensity and cell density in the site represents the cell activity.

  3. Pelvic Incidence: A Predictive Factor for Three-Dimensional Acetabular Orientation—A Preliminary Study

    Directory of Open Access Journals (Sweden)

    Christophe Boulay

    2014-01-01

    Full Text Available Acetabular cup orientation (inclination and anteversion is a fundamental topic in orthopaedics and depends on pelvis tilt (positional parameter emphasising the notion of a safe range of pelvis tilt. The hypothesis was that pelvic incidence (morphologic parameter could yield a more accurate and reliable assessment than pelvis tilt. The aim was to find out a predictive equation of acetabular 3D orientation parameters which were determined by pelvic incidence to include in the model. The second aim was to consider the asymmetry between the right and left acetabulae. Twelve pelvic anatomic specimens were measured with an electromagnetic Fastrak system (Polhemus Society providing 3D position of anatomical landmarks to allow measurement of acetabular and pelvic parameters. Acetabulum and pelvis data were correlated by a Spearman matrix. A robust linear regression analysis provided prediction of acetabulum axes. The orientation of each acetabulum could be predicted by the incidence. The incidence is correlated with the morphology of acetabula. The asymmetry of the acetabular roof was correlated with pelvic incidence. This study allowed analysis of relationships of acetabular orientation and pelvic incidence. Pelvic incidence (morphologic parameter could determine the safe range of pelvis tilt (positional parameter for an individual and not a group.

  4. Three-dimensional numerical study on the mechanism of anisotropic MCCI by improved MPS method

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xin, E-mail: lixin@fuji.waseda.jp; Yamaji, Akifumi

    2017-04-01

    Highlights: • 3-D simulation of a MCCI test was presented with improved moving particle method. • The influence of thermally stable silica aggregates on MCCI has been investigated. • The mechanisms for isotropic/anisotropic ablation have been clarified mechanistically. - Abstract: In two-dimensional (2-D) molten corium-concrete interaction (MCCI) experiments with prototypic corium and siliceous concrete, the more pronounced lateral concrete erosion behavior than that in the axial direction, namely anisotropic ablation, has been a research interest. However, the knowledge of the mechanism on this anisotropic ablation behavior, which is important for severe accident analysis and management, is still limited. In this paper, 3-D simulation of 2-D MCCI experiment VULCANO VB-U7 has been carried out with improved Moving Particle Semi-implicit (MPS) method. Heat conduction, phase change, and corium viscosity models have been developed and incorporated into MPS code MPS-SW-MAIN-Ver.2.0 for current study. The influence of thermally stable silica aggregates has been investigated by setting up different simulation cases for analysis. The simulation results suggested reasonable models and assumptions to be considered in order to achieve best estimation of MCCI with prototypic oxidic corium and siliceous concrete. The simulation results also indicated that silica aggregates can contribute to anisotropic ablation. The mechanisms for anisotropic ablation pattern in siliceous concrete as well as isotropic ablation pattern in limestone-rich concrete have been clarified from a mechanistic perspective.

  5. An experimental study of the dynamics of saltation within a three-dimensional framework

    Science.gov (United States)

    O'Brien, Patrick; McKenna Neuman, Cheryl

    2018-04-01

    Our understanding of aeolian sand transport via saltation lacks an experimental determination of the particle borne kinetic energy partitioned into 3 dimensions relative to the mean flow direction. This in turn creates a disconnect between global wind erosion estimates and particle scale processes. The present study seeks to address this deficiency through an extended analysis of data obtained from a series of particle tracking velocimetry experiments conducted in a boundary layer wind tunnel under transport limited conditions. Particle image diameter, as it appeared within each camera frame, was extensively calibrated against that obtained by sieving, and the ballistic trajectories detected were disassembled into discrete particle image pairs whose distribution and dynamics were then examined in vertical profile with sub-millimeter resolution. The vertical profile of the wind aligned particle transport rate was found to follow a power relation within 10 mm of the bed surface. The exponent of this power function changes with increasing spanwise angle (θ) to produce a family of curves representing particle diffusion in 3 dimensions. Particle mass was found to increase with θ, and the distribution of the total particle kinetic energy was found to be very similar to that for the particle concentration. The spanwise component of the kinetic energy of a saltating particle peaks at θ = 45°, with the stream-aligned component an order of magnitude higher in value. Low energy, splashed particles near the bed account for a majority of the kinetic energy distributed throughout the particle cloud, regardless of their orientation.

  6. Three-Dimensional Analysis of the Characteristics of the Femoral Canal Isthmus: An Anatomical Study

    Directory of Open Access Journals (Sweden)

    Xiu-yun Su

    2015-01-01

    Full Text Available Purpose. To establish a new approach for measuring and locating the femoral intramedullary canal isthmus in 3-dimensional (3D space. Methods. Based on the computed tomography data from 204 Chinese patients, 3D models of the whole femur and the corresponding femoral isthmus tube were reconstructed using Mimics software (Materialise, Haasrode, Belgium. The anatomical parameters of the femur and the isthmus, including the femur length and radius, and the isthmus diameter and height, were measured accordingly. Results. The mean ratio of the isthmus height versus the femoral height was 55 ± 4.8%. The mean diameter of the isthmus was 10.49 ± 1.52 mm. The femoral length, the isthmus diameter, and the isthmus tube length were significantly larger in the male group. Significant correlations were observed between the femoral length and the isthmus diameter (r=0.24, p<0.01 and between the femoral length and the isthmus height (r=0.6, p<0.01. Stepwise linear regression analyses demonstrated that the femoral length and radius were the most important factors influencing the location and dimension of the femoral canal isthmus. Conclusion. The current study developed a new approach for measuring the femoral canal and for optimization of customer-specific femoral implants.

  7. A study of three-dimensional gravity currents on a uniform slope

    Science.gov (United States)

    Ross, Andrew N.; Linden, P. F.; Dalziel, Stuart B.

    2002-02-01

    In many geophysical, environmental and industrial situations, a finite volume of fluid with a density different to the ambient is released on a sloping boundary. This leads to the formation of a gravity current travelling up, down and across the slope. We present novel laboratory experiments in which the dense fluid spreads both down-slope (and initially up-slope) and laterally across the slope. The position, shape and dilution of the current are determined through video and conductivity measurements for moderate slopes (5° to 20°). The entrainment coefficient for different slopes is calculated from the experimental results and is found to depend very little on the slope. The value agrees well with previously published values for entrainment into gravity currents on a horizontal surface. The experimental measurements are compared with previous shallow-water models and with a new wedge integral model developed and presented here. It is concluded that these simplified models do not capture all the significant features of the flow. In the models, the current takes the form of a wedge which travels down the slope, but the experiments show the formation of a more complicated current. It is found that the wedge integral model over-predicts the length and width of the gravity current but gives fair agreement with the measured densities in the head. The initial stages of the flow, during which time the wedge shape develops, are studied. It is found that although the influence of the slope is seen relatively quickly for moderate slopes, the time taken for the wedge to develop is much longer. The implications of these findings for safety analysis are briefly discussed.

  8. Three-dimensional quantum mechanical studies of D+H2 → HD+H reactive scattering

    International Nuclear Information System (INIS)

    Tang, K.T.; Choi, B.H.

    1975-01-01

    A three-dimensional quantum mechanical study is made on the reactive scattering of D+H 2 → DH+H. The differential and total cross sections as well as the S-matrix elements are obtained from the adiabatic distorted wave model. With the initial molecule H 2 in the ground rotational state, we calculated the cross sections for reactions to all possible rotational states of the product molecule DH. The potential used is that of the Porter and Karplus semiempirical surface. The reactive scattering is predominantly backward. However, the peak in the differential cross sections gradually shifts away from theta=π as the energy is increased, with higher rotational states shifting more. In the thermal energy region, there is virtually no scattering in forward directions. The reaction is endothermic but only slightly so. Although the 0→0 rotational transition contributes only a small fraction to the total reactive cross section, most product molecules prefer rotational states that are considerably lower than the highest one allowed by energy conservation. Differential cross sections summed over all possible final rotational states are significantly different from that of any one state. Previous three-dimensional quantum mechanical studies on this system are all limited to one final rotational state; these previous results are compared with the result of the corresponding case in the present study. The present results are also compared with the corresponding classical trajectory calculations on the same potential surface. Finally, the experimental measurements of Geddes, Kraus, and Fite are compared with the present results. Qualitatively, there are general agreements. but quantitatively the calculated cross sections are definitely too large as compared with the experimental ones. The most likely cause for this difference is that the potential surface used is ''too reactive.''

  9. Three Dimensional Modelling of Canister for Spent Nuclear Fuel - some migration studies

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Antonio [AlbaNova Univ. Center, Stockholm (Sweden). Dept. of Physics

    2006-08-15

    Performance assessment transport models use extensively the concept of transport resistance in the calculation of breakthrough curves of radionuclide releases in the near field and geosphere. The aim of this work is to examine more closely the applicability of the transport resistance approach. Can the resistance approach be used in for the estimation of fluxes through a pinhole of a defected canister? Or for the estimation of fluxes as given by the resistance of a fracture that crosses a canister hole? And if so, what is the degree of conservatism (if any) introduced by the use of that concept? Two near-field 3D-models of the system consisting of canister, bentonite buffer and fracture have been developed. The goal is to examine the contribution to mass-transfer resistance of the interfaces between pinhole and bentonite buffer and between bentonite buffer and fracture respectively and to compare them with the resistance approach used by SKB in their compartment models of the near field. For this purpose we have developed two 3D models using the FEMLAB tool, to perform the set of calculations presented in this report. We estimate the above mentioned resistances separately for the interface between pinhole and bentonite buffer and for the interface between bentonite buffer and fracture respectively and we make a series of parameter variation studies. We conclude that the pinhole resistance used by SKB is a good approach to be used by compartment models even if some small discrepancy exists whenever the cross-section of the pinhole is larger than 10{sup -4} m{sup 2}. In respect to the fracture resistance parameterisation used in some SKB compartment models, the method is clearly conservative in many cases, with the exception for time points shorter than 200 years. This is due to the fact that the transient breakthrough curves cannot be described accurately by the parameterisation derived from the solution of the steady state equations used as the start point to

  10. Three-dimensional quantitative analysis of healthy foot shape: a proof of concept study.

    Science.gov (United States)

    Stanković, Kristina; Booth, Brian G; Danckaers, Femke; Burg, Fien; Vermaelen, Philippe; Duerinck, Saartje; Sijbers, Jan; Huysmans, Toon

    2018-01-01

    Foot morphology has received increasing attention from both biomechanics researches and footwear manufacturers. Usually, the morphology of the foot is quantified by 2D footprints. However, footprint quantification ignores the foot's vertical dimension and hence, does not allow accurate quantification of complex 3D foot shape. The shape variation of healthy 3D feet in a population of 31 adult women and 31 adult men who live in Belgium was studied using geometric morphometric methods. The effect of different factors such as sex, age, shoe size, frequency of sport activity, Body Mass Index (BMI), foot asymmetry, and foot loading on foot shape was investigated. Correlation between these factors and foot shape was examined using multivariate linear regression. The complex nature of a foot's 3D shape leads to high variability in healthy populations. After normalizing for scale, the major axes of variation in foot morphology are (in order of decreasing variance): arch height, combined ball width and inter-toe distance, global foot width, hallux bone orientation (valgus-varus), foot type (e.g. Egyptian, Greek), and midfoot width. These first six modes of variation capture 92.59% of the total shape variation. Higher BMI results in increased ankle width, Achilles tendon width, heel width and a thicker forefoot along the dorsoplantar axis. Age was found to be associated with heel width, Achilles tendon width, toe height and hallux orientation. A bigger shoe size was found to be associated with a narrow Achilles tendon, a hallux varus, a narrow heel, heel expansion along the posterior direction, and a lower arch compared to smaller shoe size. Sex was found to be associated with differences in ankle width, Achilles tendon width, and heel width. Frequency of sport activity was associated with Achilles tendon width and toe height. A detailed analysis of the 3D foot shape, allowed by geometric morphometrics, provides insights in foot variations in three dimensions that can not be

  11. Three Dimensional Modelling of a KBS-3 Canister for Spent Nuclear Fuel - some migration studies

    International Nuclear Information System (INIS)

    Pereira, Antonio

    2006-08-01

    Performance assessment transport models use extensively the concept of transport resistance in the calculation of breakthrough curves of radionuclide releases in the near field and geosphere. The aim of this work is to examine more closely the applicability of the transport resistance approach. Can the resistance approach be used in for the estimation of fluxes through a pinhole of a defected canister? Or for the estimation of fluxes as given by the resistance of a fracture that crosses a canister hole? And if so, what is the degree of conservatism (if any) introduced by the use of that concept? Two near-field 3D-models of the system consisting of canister, bentonite buffer and fracture have been developed. The goal is to examine the contribution to mass-transfer resistance of the interfaces between pinhole and bentonite buffer and between bentonite buffer and fracture respectively and to compare them with the resistance approach used by SKB in their compartment models of the near field. For this purpose we have developed two 3D models using the FEMLAB tool, to perform the set of calculations presented in this report. We estimate the above mentioned resistances separately for the interface between pinhole and bentonite buffer and for the interface between bentonite buffer and fracture respectively and we make a series of parameter variation studies. We conclude that the pinhole resistance used by SKB is a good approach to be used by compartment models even if some small discrepancy exists whenever the cross-section of the pinhole is larger than 10 -4 m 2 . In respect to the fracture resistance parameterisation used in some SKB compartment models, the method is clearly conservative in many cases, with the exception for time points shorter than 200 years. This is due to the fact that the transient breakthrough curves cannot be described accurately by the parameterisation derived from the solution of the steady state equations used as the start point to deduce the

  12. Monte Carlo study of the three-dimensional spatially anisotropic Ising superantiferromagnet in the presence of a magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Salmon, Octavio D.R., E-mail: octaviors@gmail.com [Departamento de Física, Universidade Federal do Amazonas, 3000, Japiim, 69077-000 Manaus-AM (Brazil); Neto, Minos A., E-mail: minosneto@pq.cnpq.br [Departamento de Física, Universidade Federal do Amazonas, 3000, Japiim, 69077-000 Manaus-AM (Brazil); Viana, J. Roberto, E-mail: vianafisica@bol.com.br [Departamento de Física, Universidade Federal do Amazonas, 3000, Japiim, 69077-000 Manaus-AM (Brazil); Padilha, Igor T., E-mail: igorfis@ufam.edu.br [Departamento de Física, Universidade Federal do Amazonas, 3000, Japiim, 69077-000 Manaus-AM (Brazil); Sousa, J. Ricardo de, E-mail: jsousa@ufam.edu.br [Departamento de Física, Universidade Federal do Amazonas, 3000, Japiim, 69077-000 Manaus-AM (Brazil); National Institute of Science and Technology for Complex Systems, 3000, Japiim, 69077-000 Manaus-AM (Brazil)

    2013-11-01

    The phase transition of the three-dimensional spatially anisotropic Ising antiferromagnetic model in the presence of an uniform longitudinal magnetic field H is studied by using the traditional Monte Carlo (MC) simulation for sizes L=16, 32 and 64. The model consists of ferromagnetic interactions J{sub z}=λ{sub 2}J{sub x} in the x(z) direction and antiferromagnetic interactions J{sub y}=λ{sub 1}J{sub x} in the y direction (Ising superantiferromagnetic). For the particular case λ{sub 1}=λ{sub 2}=1 we obtain the phase diagram in the T–H plane. Was observed first- and second-order transitions in the low and high temperature limits, respectively, with the presence of a tricritical point.

  13. Three-dimensional vs. two-dimensional shear-wave elastography of the testes - preliminary study on a healthy collective.

    Science.gov (United States)

    Marcon, J; Trottmann, M; Rübenthaler, J; D'Anastasi, M; Stief, C G; Reiser, M F; Clevert, D A

    2016-01-01

    Shear wave elastography (SWE) and its derivative Supersonic Shear Imaging (SSI) are newer techniques for the determination of tissue elasticity by measuring the velocity of generated shear waves (SWV), which correlates positively with tissue stiffness.The techniques are integrated into many modern ultrasound systems and have been examined in the evaluation of viscoelastic properties of different organ systems. Two-dimensional shear wave elastography (2D SWE) of the testes has been found to be a useful tool in recent studies which included the determination of standard values in healthy volunteers. Three-dimensional shear wave elastography (3D SWE) is the latest development in elastography and is made possible by generation of a multiplanar three-dimensional map via volumetric acquisition with a special ultrasound transducer. This technique allows the assessment of tissue elasticity in a three-dimensional, fully accessible organ map.The aim of this preliminary study was to both evaluate the feasibility of 3D SWE and to compare 2D and 3D SWE standard values in the testes of healthy subjects. We examined the testes of healthy male volunteers (n = 32) with a mean age of 51.06±17.75 years (range 25-77 years) by B-mode ultrasound, 2D and 3D SWE techniques in September of 2016. Volunteers with a history of testicular pathologies were excluded. For all imaging procedures the SL15-4 linear transducer (bandwidth 4-15 MHz) as well as the SLV16-4 volumetric probe (bandwidth 4-16 MHz) of the Aixplorer® ultrasound device (SuperSonic Imagine, Aix-en-Provence, France) were used. Seven regions of interest (ROI, Q-Box®) within the testes were evaluated for SWV using both procedures. SWV values were described in m/s. Results were statistically evaluated using univariateanalysis. Mean SWV values were 1.05 m/s for the 2D SWE and 1.12 m/s for the 3D SWE.Comparisons of local areas delivered no statistically significant differences (p = 0.11 to p = 0.66), except for

  14. Three-dimensional dose distribution in contrast-enhanced digital mammography using Gafchromic XR-QA2 films: Feasibility study

    International Nuclear Information System (INIS)

    Hwang, Yi-Shuan; Lin, Yu-Ying; Cheung, Yun-Chung; Tsai, Hui-Yu

    2014-01-01

    This study was aimed to establish three-dimensional dose distributions for contrast-enhanced digital mammography (CEDM) using self-developed Gafchromic XR-QA2 films. Dose calibration and distribution evaluations were performed on a full-field digital mammography unit with dual energy (DE) contrast-enhanced option. Strategy for dose calibration of films in the DE mode was based on the data obtained from common target/filter/kVp combinations used clinically and the dose response model modified from Rampado's model. Dose derived from films were also verified by measured data from an ionization chamber. The average difference of dose was 8.9% in the dose range for clinical uses. Three-dimensional dose distributions were estimated using triangular acrylic phantom equipped with the mammography system. Five pieces of film sheets were separately placed between the acrylic slabs to evaluate the dose distribution at different depths. After normalizing the dose in each pixel to the maximum dose at the top-center position of the acrylic, normalized dose distribution for transverse, coronal and sagittal planes, could thus be obtained. The depth dose distribution evaluated in this study may further serve as a reference for evaluating the patient glandular dose at different depths based on the entrance exposure information. - Highlights: • CEDM techniques can enhance contrast uptake areas and suppress background tissue. • Dose for the dual-energy acquisition is about 20% higher than standard mode. • A new method is proposed to estimate the 3D dose distribution in dual-energy CEDM. • Depth of normalized dose ratio of 0.5 is less than but near 1 cm in the DE mode

  15. Three-dimensional chitin rings from body segments of a pet diplopod species: Characterization and protein interaction studies

    Energy Technology Data Exchange (ETDEWEB)

    Kaya, Murat, E-mail: muratkaya3806@yahoo.com [Department of Biotechnology and Molecular Biology, Faculty of Science and Letters, Aksaray University, 68100 Aksaray (Turkey); Mulerčikas, Povilas [Department of Biology and Plant Protection, Lithuanian University of Agriculture, LT-53361 (Lithuania); Sargin, Idris [Department of Chemistry, Faculty of Science, Selcuk University, 42075 Konya (Turkey); Kazlauskaitė, Sonata [Department of Biology and Plant Protection, Lithuanian University of Agriculture, LT-53361 (Lithuania); Baublys, Vykintas [Department of Biology, Vytautas Magnus University, LT-44404 Kaunas (Lithuania); Akyuz, Bahar; Bulut, Esra [Department of Biotechnology and Molecular Biology, Faculty of Science and Letters, Aksaray University, 68100 Aksaray (Turkey); Tubelytė, Vaida [Department of Biology, Vytautas Magnus University, LT-44404 Kaunas (Lithuania)

    2016-11-01

    Physicochemical characterization of new chitin isolates can provide valuable insights into designing of biomimetic materials. Chitin isolates with a definite three-dimensional (3D) structure can exhibit characteristics that distinguish them from other chitin specimens that are in form of powder or flakes without a definite and uniform shape. Herein, 3D chitin rings were produced from body segments of a diplopod (Archispirostreptus gigas) inhabiting tropical regions. This organism is cultured easily and can reach 38 cm in length, which makes it a suitable source for isolation of chitin. The chitin rings were characterized via TGA, FT-IR, SEM and XRD analyses. Enzymatic digestion test with chitinase demonstrated that chitin isolates had high purity (digestion rate: 97.4%). The source organism had high chitin content; 21.02 ± 2.23% on dry weight. Interactions of the chitin rings with bovine serum albumin (BSA) protein were studied under different conditions (pH: 4.0–8.0, chitin amount: 6–14 mg, contact time: 30–360 min, protein concentration: 0.2–1 mg/mL). The highest BSA adsorption was observed at pH 5.0 at 20 °C. The adsorption equilibrium data exhibited a better fit to Langmuir adsorption and the pseudo-first order kinetic models. The findings presented here can be useful for further studies aiming to develop biocompatible and nontoxic biomaterials. - Highlights: • Three-dimensional ring shaped chitin was produced from a pet diplopod species. • Archispirostreptus gigas has high chitin content; 21.02 ± 2.23% on dry weight. • Chitinase enzyme showed activity on the chitin rings with digestion rate of 97.4%. • The highest bovine serum albumin (BSA) adsorption was observed at pH 5.0 at 20 °C.

  16. Three-Dimensional Muscle Architecture and Comprehensive Dynamic Properties of Rabbit Gastrocnemius, Plantaris and Soleus: Input for Simulation Studies.

    Science.gov (United States)

    Siebert, Tobias; Leichsenring, Kay; Rode, Christian; Wick, Carolin; Stutzig, Norman; Schubert, Harald; Blickhan, Reinhard; Böl, Markus

    2015-01-01

    The vastly increasing number of neuro-muscular simulation studies (with increasing numbers of muscles used per simulation) is in sharp contrast to a narrow database of necessary muscle parameters. Simulation results depend heavily on rough parameter estimates often obtained by scaling of one muscle parameter set. However, in vivo muscles differ in their individual properties and architecture. Here we provide a comprehensive dataset of dynamic (n = 6 per muscle) and geometric (three-dimensional architecture, n = 3 per muscle) muscle properties of the rabbit calf muscles gastrocnemius, plantaris, and soleus. For completeness we provide the dynamic muscle properties for further important shank muscles (flexor digitorum longus, extensor digitorum longus, and tibialis anterior; n = 1 per muscle). Maximum shortening velocity (normalized to optimal fiber length) of the gastrocnemius is about twice that of soleus, while plantaris showed an intermediate value. The force-velocity relation is similar for gastrocnemius and plantaris but is much more bent for the soleus. Although the muscles vary greatly in their three-dimensional architecture their mean pennation angle and normalized force-length relationships are almost similar. Forces of the muscles were enhanced in the isometric phase following stretching and were depressed following shortening compared to the corresponding isometric forces. While the enhancement was independent of the ramp velocity, the depression was inversely related to the ramp velocity. The lowest effect strength for soleus supports the idea that these effects adapt to muscle function. The careful acquisition of typical dynamical parameters (e.g. force-length and force-velocity relations, force elongation relations of passive components), enhancement and depression effects, and 3D muscle architecture of calf muscles provides valuable comprehensive datasets for e.g. simulations with neuro-muscular models, development of more realistic muscle models, or

  17. Three-dimensional, automated, real-time video system for tracking limb motion in brain-machine interface studies.

    Science.gov (United States)

    Peikon, Ian D; Fitzsimmons, Nathan A; Lebedev, Mikhail A; Nicolelis, Miguel A L

    2009-06-15

    Collection and analysis of limb kinematic data are essential components of the study of biological motion, including research into biomechanics, kinesiology, neurophysiology and brain-machine interfaces (BMIs). In particular, BMI research requires advanced, real-time systems capable of sampling limb kinematics with minimal contact to the subject's body. To answer this demand, we have developed an automated video tracking system for real-time tracking of multiple body parts in freely behaving primates. The system employs high-contrast markers painted on the animal's joints to continuously track the three-dimensional positions of their limbs during activity. Two-dimensional coordinates captured by each video camera are combined and converted to three-dimensional coordinates using a quadratic fitting algorithm. Real-time operation of the system is accomplished using direct memory access (DMA). The system tracks the markers at a rate of 52 frames per second (fps) in real-time and up to 100fps if video recordings are captured to be later analyzed off-line. The system has been tested in several BMI primate experiments, in which limb position was sampled simultaneously with chronic recordings of the extracellular activity of hundreds of cortical cells. During these recordings, multiple computational models were employed to extract a series of kinematic parameters from neuronal ensemble activity in real-time. The system operated reliably under these experimental conditions and was able to compensate for marker occlusions that occurred during natural movements. We propose that this system could also be extended to applications that include other classes of biological motion.

  18. Three-Dimensional Muscle Architecture and Comprehensive Dynamic Properties of Rabbit Gastrocnemius, Plantaris and Soleus: Input for Simulation Studies.

    Directory of Open Access Journals (Sweden)

    Tobias Siebert

    Full Text Available The vastly increasing number of neuro-muscular simulation studies (with increasing numbers of muscles used per simulation is in sharp contrast to a narrow database of necessary muscle parameters. Simulation results depend heavily on rough parameter estimates often obtained by scaling of one muscle parameter set. However, in vivo muscles differ in their individual properties and architecture. Here we provide a comprehensive dataset of dynamic (n = 6 per muscle and geometric (three-dimensional architecture, n = 3 per muscle muscle properties of the rabbit calf muscles gastrocnemius, plantaris, and soleus. For completeness we provide the dynamic muscle properties for further important shank muscles (flexor digitorum longus, extensor digitorum longus, and tibialis anterior; n = 1 per muscle. Maximum shortening velocity (normalized to optimal fiber length of the gastrocnemius is about twice that of soleus, while plantaris showed an intermediate value. The force-velocity relation is similar for gastrocnemius and plantaris but is much more bent for the soleus. Although the muscles vary greatly in their three-dimensional architecture their mean pennation angle and normalized force-length relationships are almost similar. Forces of the muscles were enhanced in the isometric phase following stretching and were depressed following shortening compared to the corresponding isometric forces. While the enhancement was independent of the ramp velocity, the depression was inversely related to the ramp velocity. The lowest effect strength for soleus supports the idea that these effects adapt to muscle function. The careful acquisition of typical dynamical parameters (e.g. force-length and force-velocity relations, force elongation relations of passive components, enhancement and depression effects, and 3D muscle architecture of calf muscles provides valuable comprehensive datasets for e.g. simulations with neuro-muscular models, development of more realistic

  19. Accuracy of Cup Positioning With the Computed Tomography-Based Two-dimensional to Three-Dimensional Matched Navigation System: A Prospective, Randomized Controlled Study.

    Science.gov (United States)

    Yamada, Kazuki; Endo, Hirosuke; Tetsunaga, Tomonori; Miyake, Takamasa; Sanki, Tomoaki; Ozaki, Toshifumi

    2018-01-01

    The accuracy of various navigation systems used for total hip arthroplasty has been described, but no publications reported the accuracy of cup orientation in computed tomography (CT)-based 2D-3D (two-dimensional to three-dimensional) matched navigation. In a prospective, randomized controlled study, 80 hips including 44 with developmental dysplasia of the hips were divided into a CT-based 2D-3D matched navigation group (2D-3D group) and a paired-point matched navigation group (PPM group). The accuracy of cup orientation (absolute difference between the intraoperative record and the postoperative measurement) was compared between groups. Additionally, multiple logistic regression analysis was performed to evaluate patient factors affecting the accuracy of cup orientation in each navigation. The accuracy of cup inclination was 2.5° ± 2.2° in the 2D-3D group and 4.6° ± 3.3° in the PPM group (P = .0016). The accuracy of cup anteversion was 2.3° ± 1.7° in the 2D-3D group and 4.4° ± 3.3° in the PPM group (P = .0009). In the PPM group, the presence of roof osteophytes decreased the accuracy of cup inclination (odds ratio 8.27, P = .0140) and the absolute value of pelvic tilt had a negative influence on the accuracy of cup anteversion (odds ratio 1.27, P = .0222). In the 2D-3D group, patient factors had no effect on the accuracy of cup orientation. The accuracy of cup positioning in CT-based 2D-3D matched navigation was better than in paired-point matched navigation, and was not affected by patient factors. It is a useful system for even severely deformed pelvises such as developmental dysplasia of the hips. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Utility of the three-dimensional reconstruction by means of helical scanography in the study of stringed instruments

    International Nuclear Information System (INIS)

    Morillo Zarate, Anibal Jose; Uriza Carrasco, Luis Felipe

    1998-01-01

    The evaluation of stringed instruments with axial computerized tomography (CT) sections has been described as a reliable method for the study of its internal components and for the detection of damaged instruments. We present the application of helical CT with thin sections and 3-D reconstructions in a series of violins, for an anatomical study of the instrument. The 3-D images offer complementary information and permit a better evaluation of the internal structure of the violin that can be useful for the understanding of the secrets of its construction and for the diagnosis of structural lesions that can affect its acoustic performance

  1. Three-Dimensional Flows

    CERN Document Server

    Araujo, Vitor; Viana, Marcelo

    2010-01-01

    In this book, the authors present the elements of a general theory for flows on three-dimensional compact boundaryless manifolds, encompassing flows with equilibria accumulated by regular orbits. The book aims to provide a global perspective of this theory and make it easier for the reader to digest the growing literature on this subject. This is not the first book on the subject of dynamical systems, but there are distinct aspects which together make this book unique. Firstly, this book treats mostly continuous time dynamical systems, instead of its discrete counterpart, exhaustively treated

  2. Three dimensional system integration

    CERN Document Server

    Papanikolaou, Antonis; Radojcic, Riko

    2010-01-01

    Three-dimensional (3D) integrated circuit (IC) stacking is the next big step in electronic system integration. It enables packing more functionality, as well as integration of heterogeneous materials, devices, and signals, in the same space (volume). This results in consumer electronics (e.g., mobile, handheld devices) which can run more powerful applications, such as full-length movies and 3D games, with longer battery life. This technology is so promising that it is expected to be a mainstream technology a few years from now, less than 10-15 years from its original conception. To achieve thi

  3. Three dimensional visualization of medical images

    International Nuclear Information System (INIS)

    Suto, Yasuzo

    1992-01-01

    Three dimensional visualization is a stereoscopic technique that allows the diagnosis and treatment of complicated anatomy site of the bone and organ. In this article, the current status and technical application of three dimensional visualization are introduced with special reference to X-ray CT and MRI. The surface display technique is the most common for three dimensional visualization, consisting of geometric model, voxel element, and stereographic composition techniques. Recent attention has been paid to display method of the content of the subject called as volume rendering, whereby information on the living body is provided accurately. The application of three dimensional visualization is described in terms of diagnostic imaging and surgical simulation. (N.K.)

  4. Comparison of Wenner and dipole–dipole arrays in the study of an underground three-dimensional cavity

    International Nuclear Information System (INIS)

    Neyamadpour, Ahmad; Wan Abdullah, W A T; Taib, Samsudin; Neyamadpour, Behrang

    2010-01-01

    The objective of this paper was to compare Wenner and dipole–dipole configurations in delineating an underground cavity at a site near the University of Malaya, Malaysia. A three-dimensional electrical resistivity imaging survey was carried out along seven parallel lines using Wenner and dipole–dipole arrays. A three-dimensional least-squares algorithm, based on the robust inversion method, was used in the inversion of the apparent resistivity data. In the inverted model, both the horizontal and vertical extents of the anomalous zones were displayed. Results indicate the superiority of the Wenner array over the dipole–dipole array for determining the vertical distribution of the subsurface resistivity, although the dipole–dipole array produced a better lateral extent of the subsurface features. The results show that the three-dimensional electrical resistivity imaging survey using both the Wenner and dipole–dipole arrays, in combination with an appropriate three-dimensional inversion method and synthetic model analysis, can be highly useful for engineering and environmental applications, especially for underground three-dimensional cavity detection

  5. Three-dimensional organization of pKi-67: a comparative fluorescence and electron tomography study using FluoroNanogold.

    Science.gov (United States)

    Cheutin, Thierry; O'Donohue, Marie-Françoise; Beorchia, Adrien; Klein, Christophe; Kaplan, Hervé; Ploton, Dominique

    2003-11-01

    The monoclonal antibody (MAb) Ki-67 is routinely used in clinical studies to estimate the growth fraction of tumors. However, the role of pKi-67, the protein detected by the Ki-67 MAb, remains elusive, although some biochemical data strongly suggest that it might organize chromatin. To better understand the functional organization of pKi-67, we studied its three-dimensional distribution in interphase cells by confocal microscopy and electron tomography. FluoroNanogold, a single probe combining a dense marker with a fluorescent dye, was used to investigate pKi-67 organization at the optical and ultrastructural levels. Observation by confocal microscopy followed by 3D reconstruction showed that pKi-67 forms a shell around the nucleoli. Double labeling experiments revealed that pKi-67 co-localizes with perinucleolar heterochromatin. Electron microscopy studies confirmed this close association and demonstrated that pKi-67 is located neither in the fibrillar nor in the granular components of the nucleolus. Finally, spatial analyses by electron tomography showed that pKi-67 forms cords 250-300 nm in diameter, which are themselves composed of 30-50-nm-thick fibers. These detailed comparative in situ analyses strongly suggest the involvement of pKi-67 in the higher-order organization of perinucleolar chromatin.

  6. Tumor cell culture on collagen–chitosan scaffolds as three-dimensional tumor model: A suitable model for tumor studies

    Directory of Open Access Journals (Sweden)

    Aziz Mahmoudzadeh

    2016-07-01

    Full Text Available Tumor cells naturally live in three-dimensional (3D microenvironments, while common laboratory tests and evaluations are done in two-dimensional (2D plates. This study examined the impact of cultured 4T1 cancer cells in a 3D collagen–chitosan scaffold compared with 2D plate cultures. Collagen–chitosan scaffolds were provided and passed confirmatory tests. 4T1 tumor cells were cultured on scaffolds and then tumor cells growth rate, resistance to X-ray radiation, and cyclophosphamide as a chemotherapy drug were analyzed. Furthermore, 4T1 cells were extracted from the scaffold model and were injected into the mice. Tumor growth rate, survival rate, and systemic immune responses were evaluated. Our results showed that 4T1 cells infiltrated the scaffolds pores and constructed a 3D microenvironment. Furthermore, 3D cultured tumor cells showed a slower proliferation rate, increased levels of survival to the X-ray irradiation, and enhanced resistance to chemotherapy drugs in comparison with 2D plate cultures. Transfer of extracted cells to the mice caused enhanced tumor volume and decreased life span. This study indicated that collagen–chitosan nanoscaffolds provide a suitable model of tumor that would be appropriate for tumor studies.

  7. Tumor cell culture on collagen-chitosan scaffolds as three-dimensional tumor model: A suitable model for tumor studies.

    Science.gov (United States)

    Mahmoudzadeh, Aziz; Mohammadpour, Hemn

    2016-07-01

    Tumor cells naturally live in three-dimensional (3D) microenvironments, while common laboratory tests and evaluations are done in two-dimensional (2D) plates. This study examined the impact of cultured 4T1 cancer cells in a 3D collagen-chitosan scaffold compared with 2D plate cultures. Collagen-chitosan scaffolds were provided and passed confirmatory tests. 4T1 tumor cells were cultured on scaffolds and then tumor cells growth rate, resistance to X-ray radiation, and cyclophosphamide as a chemotherapy drug were analyzed. Furthermore, 4T1 cells were extracted from the scaffold model and were injected into the mice. Tumor growth rate, survival rate, and systemic immune responses were evaluated. Our results showed that 4T1 cells infiltrated the scaffolds pores and constructed a 3D microenvironment. Furthermore, 3D cultured tumor cells showed a slower proliferation rate, increased levels of survival to the X-ray irradiation, and enhanced resistance to chemotherapy drugs in comparison with 2D plate cultures. Transfer of extracted cells to the mice caused enhanced tumor volume and decreased life span. This study indicated that collagen-chitosan nanoscaffolds provide a suitable model of tumor that would be appropriate for tumor studies. Copyright © 2016. Published by Elsevier B.V.

  8. Use of three-dimensional lognormal dose-response surfaces in lifetime studies of radiation-induced cancer

    International Nuclear Information System (INIS)

    Raabe, O.G.

    1986-01-01

    The three-dimensional lognormal cumulative probability power function was used to provide a unifying dose-response description of the lifetime cancer risk for chronic exposure of experimental animals and people, for risk evaluation, and for scaling between species. Bone tumor fatilities, primarily from alpha irradiation of the skeleton in lifetime studies of beagles injected with 226 Ra, were shown to be well described by this function. This function described cancer risk in lifetime studies as a curved smooth surface depending on radiation exposure rate and elapsed time, such that the principal risk at low dose rates occurred near the end of the normal life span without significant life shortening. Essentially identical functions with the median value of the power function displaced with respect to appropriate RBE values were shown to describe bone-cancer induction primarily from alpha irradiation of the skeleton in lifetime beagle studies with injected 226 Ra, 228 Th, 239 Pu and 241 Am, and with inhaled 238 Pu. Application of this model to human exposures to 226 Ra yielded a response ratio of 3.6; that is, the time required for development of bone cancer in people was 3.6 times longer than for beagles at the same average skeletal dose rate. It was suggested that similar techniques were appropriate to other carcinogens and other critical organs. 20 refs., 8 figs., 3 tabs

  9. Three Dimensional Dirac Semimetals

    Science.gov (United States)

    Zaheer, Saad

    2014-03-01

    Dirac points on the Fermi surface of two dimensional graphene are responsible for its unique electronic behavior. One can ask whether any three dimensional materials support similar pseudorelativistic physics in their bulk electronic spectra. This possibility has been investigated theoretically and is now supported by two successful experimental demonstrations reported during the last year. In this talk, I will summarize the various ways in which Dirac semimetals can be realized in three dimensions with primary focus on a specific theory developed on the basis of representations of crystal spacegroups. A three dimensional Dirac (Weyl) semimetal can appear in the presence (absence) of inversion symmetry by tuning parameters to the phase boundary separating a bulk insulating and a topological insulating phase. More generally, we find that specific rules governing crystal symmetry representations of electrons with spin lead to robust Dirac points at high symmetry points in the Brillouin zone. Combining these rules with microscopic considerations identifies six candidate Dirac semimetals. Another method towards engineering Dirac semimetals involves combining crystal symmetry and band inversion. Several candidate materials have been proposed utilizing this mechanism and one of the candidates has been successfully demonstrated as a Dirac semimetal in two independent experiments. Work carried out in collaboration with: Julia A. Steinberg, Steve M. Young, J.C.Y. Teo, C.L. Kane, E.J. Mele and Andrew M. Rappe.

  10. Eustachian tube three-dimensional reconstruction of secretory otitis media

    International Nuclear Information System (INIS)

    Yu Yafeng; Zhou Weirong; Bao Xueping; Li Min; Hu Zhenmin

    2006-01-01

    Objective: To study relationship between Eustachian tube and secretory otitis media and to explore the pathogeny of secretory otitis by three-dimensional reconstruction of Eustachian tube. Methods: Thirty cases of secretory otitis media (male 19, female 11) were selected randomly. Everyone was checked by otoscope and audiometry. Their bilateral Eustachian tubes were scanning by helix CT while making Valsalva's action. All images were passed on to work station to make three-dimensional reconstruction. Results: Four patients were found have Eustachian tube diseases, while most of patients' Eustachian tubes ventilated normally. Conclusions: Three-dimensional reconstruction of Eustachian tube can open out some pathogens of some secretory otitis medias. It will be helpful to diagnosis and therapy of secretory otitis media. (authors)

  11. Three-dimensional printing model improves morphological understanding in acetabular fracture learning: A multicenter, randomized, controlled study.

    Directory of Open Access Journals (Sweden)

    Zhenfei Huang

    Full Text Available Conventional education results in unsatisfactory morphological understanding of acetabular fractures due to lack of three-dimensional (3D details and tactile feedback of real fractures. Virtual reality (VR and 3D printing (3DP techniques are widely applied in teaching. The purpose of this study was to identify the effect of physical model (PM, VR and 3DP models in education of morphological understanding of acetabular fractures. 141 students were invited to participate in this study. Participants were equally and randomly assigned to the PM, VR and 3DP learning groups. Three-level objective tests were conducted to evaluate learning, including identifying anatomical landmarks, describing fracture lines, identifying classification, and inferring fracture mechanism. Four subjective questions were asked to evaluate the usability and value of instructional materials. Generally, the 3DP group showed a clear advantage over the PM and VR groups in objective tests, while there was no significant difference between the PM and VR groups. 3DP was considered to be the most valuable learning tool for understanding acetabular fractures. The findings demonstrate that 3DP modelling of real fractures is an effective learning instrument that can be used to understand the morphology of acetabular fractures and promote subjective interest.

  12. Computational study of effects of tension imbalance on phonation in a three-dimensional tubular larynx model.

    Science.gov (United States)

    Xue, Qian; Zheng, Xudong; Mittal, Rajat; Bielamowicz, Steven

    2014-07-01

    The present study explores the use of a continuum-based computational model to investigate the effect of left-right tension imbalance on vocal fold (VF) vibrations and glottal aerodynamics, as well as its implication on phonation. The study allows us to gain new insights into the underlying physical mechanism of irregularities induced by VF tension imbalance associated with unilateral cricothyroid muscle paralysis. A three-dimensional simulation of glottal flow and VF dynamics in a tubular laryngeal model with tension imbalance was conducted by using a coupled flow-structure interaction computational model. Tension imbalance was modeled by reducing by 20% the Young's modulus of one of the VFs, while holding VF length constant. Effects of tension imbalance on vibratory characteristic of the VFs and on the time-varying properties of glottal airflow as well as the aerodynamic energy transfer are comprehensively analyzed. The analysis demonstrates that the continuum-based biomechanical model can provide a good description of phonatory dynamics in tension imbalance conditions. It is found that although 20% tension imbalance does not have noticeable effects on the fundamental frequency, it does lead to a larger glottal flow leakage and asymmetric vibrations of the two VFs. A detailed analysis of the energy transfer suggests that the majority of the energy is consumed by the lateral motion of the VFs and the net energy transferred to the softer fold is less than the one transferred to the normal fold. Copyright © 2014 The Voice Foundation. Published by Mosby, Inc. All rights reserved.

  13. Composite resin reinforced with pre-tensioned fibers: a three-dimensional finite element study on stress distribution.

    Science.gov (United States)

    Jie, Lin; Shinya, Akikazu; Lassila, Lippo V J; Vallittu, Pekka K

    2013-01-01

    Pre-tensioned construction material is utilized in engineering applications of high strength demands. The purpose of this study was to evaluate the effect of the pre-tensioning fibers of fiber-reinforced composite (FRC) using three-dimensional finite element (FE) analysis. The 3D FE models of particulate composite resin (CR), FRC and composite resin reinforced with pre-tensioned fibers (PRE-T-FRC) were constructed. The uniaxial three-point bending test was simulated using FE analysis to calculate the principal stress distribution. In the FRC and PRE-T-FRC, stresses were higher than CR, and they were located in the fiber. However, the maximum principal stress value at the composite of PRE-T-FRC was lower than the FRC and CR. Composite resin reinforced with pre-tensioned fibers was advantageous for stress distribution and lowering the stress at the composite itself. Experimental studies on physical properties of pre-tensioned FRC are encouraged to be conducted.

  14. Three-dimensional vertical Si nanowire MOS capacitor model structure for the study of electrical versus geometrical Si nanowire characteristics

    Science.gov (United States)

    Hourdakis, E.; Casanova, A.; Larrieu, G.; Nassiopoulou, A. G.

    2018-05-01

    Three-dimensional (3D) Si surface nanostructuring is interesting towards increasing the capacitance density of a metal-oxidesemiconductor (MOS) capacitor, while keeping reduced footprint for miniaturization. Si nanowires (SiNWs) can be used in this respect. With the aim of understanding the electrical versus geometrical characteristics of such capacitors, we fabricated and studied a MOS capacitor with highly ordered arrays of vertical Si nanowires of different lengths and thermal silicon oxide dielectric, in comparison to similar flat MOS capacitors. The high homogeneity and ordering of the SiNWs allowed the determination of the single SiNW capacitance and intrinsic series resistance, as well as other electrical characteristics (density of interface states, flat-band voltage and leakage current) in relation to the geometrical characteristics of the SiNWs. The SiNW capacitors demonstrated increased capacitance density compared to the flat case, while maintaining a cutoff frequency above 1 MHz, much higher than in other reports in the literature. Finally, our model system has been shown to constitute an excellent platform for the study of SiNW capacitors with either grown or deposited dielectrics, as for example high-k dielectrics for further increasing the capacitance density. This will be the subject of future work.

  15. Three-dimensional reconstruction of colorectal tumors from serial tissue sections by computer graphics: a preliminary study.

    Science.gov (United States)

    Kikuchi, S; Matsuzaki, H; Kondo, K; Ohtani, Y; Ihara, A; Hiki, Y; Kakita, A; Kuwao, S

    2000-01-01

    We present herein the three-dimensional reconstruction of colorectal tumors, with particular reference to growth pattern into each layer of the colorectal wall, and measurement of tumor volume and surface area. Conventional tissue section images of colorectal tumors were analyzed using a computer graphics analysis program. The two-dimensional extent of invasion by each tumor into each layer of intestinal wall were determined from the images of each section. Based on data from multiple sections, tumor and surrounding normal tissue layers were reconstructed three-dimensionally, and volume and surface area of the tumors were determined. Using this technique, three-dimensional morphology of tumor and tumor progression into colorectal wall could be determined. Volume and surface area of the colon tumor were 4871 mm3 and 1741 mm2, respectively. Volume and surface area of the rectal tumor were 1090 mm3 and 877 mm2, respectively. This technique may provide a new approach for pathological analysis of colorectal carcinoma.

  16. Magnetization reversal mechanism and coercivity enhancement in three-dimensional granular Nd-Fe-B magnets studied by micromagnetic simulations

    Science.gov (United States)

    Lee, Jae-Hyeok; Choe, Jinhyeok; Hwang, Shinwon; Kim, Sang-Koog

    2017-08-01

    We studied the mechanism of magnetization reversals and coercivity enhancements in three-dimensional (3D) granular Nd-Fe-B permanent magnets using finite-element micromagnetic simulations. The magnetization reversals in the hard magnets consisting of hard-phase grains separated by relatively soft-phase grain boundaries were analyzed with reference to the simulation results for the magnetic field-dependent distributions of the local magnetizations. The saturation magnetization of the grain-boundary phase plays a crucial role in the transition between nucleation- and domain-wall-propagation-controlled reversal processes. The smaller the saturation magnetization of the grain-boundary phase is, the more preferable is the nucleation-controlled process, which results in a larger coercivity. The exchange stiffness of the grain-boundary phase determines the preferred paths of domain-wall propagations, whether inward into grains or along the grain boundaries for relatively small and large exchange stiffness, respectively. However, the exchange stiffness of the grain-boundary phase alone does not significantly contribute to coercivity enhancement in cases where the size of hard-phase grains is much greater than the exchange length. This work paves the way for the design of high-performance hard magnets of large coercivity and maximum-energy-product values.

  17. Three Dimensional Flow Field Study of the Improve Scheme for a Brushless Exciter with Rotating Parts

    Directory of Open Access Journals (Sweden)

    LU Yi-ping

    2017-06-01

    Full Text Available To study deeply the influence of the frame ring plate increased between rectifier wheel and rotor on the size of eddy current of fluid field of brushless exciter,the fluid field of complete brushless exciter model is established. Based on the computational fluid dynamics ( CFD principles ,the finite volume method is adopted to simulate and analyze the three dimensional turbulent flow field in the computational domain. The distribution character of the fluid field for the brushless exciter is obtained under rated speed,after increasing the frame ring plate between rectifier wheel and rotor. The results show increased the frame ring plate between rectifier wheel and rotor can decrease effectively the size of eddy current in the air region between rectifier wheel and rotor. Compared with the result of running scheme,the air volume flow rate of the scheme has increased 13. 89% and the result is accuracy. It provides theoretical basis for further optimizing the air ducts structure of the brushless exciter .

  18. Three-dimensional numerical study of flow and heat transfer from a cube placed in a uniform flow

    International Nuclear Information System (INIS)

    Saha, A.K.

    2006-01-01

    The fluid flow and heat transfer from a stationary cube placed in a uniform flow is studied numerically. The three-dimensional unsteady Navier Stokes and energy equations are solved using higher order temporal and spatial discretizations. Computations are carried out for a Reynolds number range of 50-400. At Re = 218, the symmetry seen at Re = 216 breaks down in one of the orthogonal planes while remains symmetric on the other thus showing a planar symmetry. The flow experiences a Hopf bifurcation at a Reynolds number between 265 and 270 and becomes unsteady. The thermal field also shows all the transitions same as those of flow transitions. The drag coefficient decreases while the heat transfer shows an increasing trend with Reynolds number. The transition from a steady to an unsteady flow does not show any significant increase in the heat transfer. Both the flow and thermal fields show multiple frequencies at high Reynolds number and the number of frequencies increases with the increase in Reynolds number. The instantaneous flow and temperature field are seen to deviate from planar symmetry at Re = 400

  19. Mathematical algorithm development and parametric studies with the GEOFRAC three-dimensional stochastic model of natural rock fracture systems

    Science.gov (United States)

    Ivanova, Violeta M.; Sousa, Rita; Murrihy, Brian; Einstein, Herbert H.

    2014-06-01

    This paper presents results from research conducted at MIT during 2010-2012 on modeling of natural rock fracture systems with the GEOFRAC three-dimensional stochastic model. Following a background summary of discrete fracture network models and a brief introduction of GEOFRAC, the paper provides a thorough description of the newly developed mathematical and computer algorithms for fracture intensity, aperture, and intersection representation, which have been implemented in MATLAB. The new methods optimize, in particular, the representation of fracture intensity in terms of cumulative fracture area per unit volume, P32, via the Poisson-Voronoi Tessellation of planes into polygonal fracture shapes. In addition, fracture apertures now can be represented probabilistically or deterministically whereas the newly implemented intersection algorithms allow for computing discrete pathways of interconnected fractures. In conclusion, results from a statistical parametric study, which was conducted with the enhanced GEOFRAC model and the new MATLAB-based Monte Carlo simulation program FRACSIM, demonstrate how fracture intensity, size, and orientations influence fracture connectivity.

  20. Liquid phase electro epitaxy growth kinetics of GaAs-A three-dimensional numerical simulation study

    International Nuclear Information System (INIS)

    Mouleeswaran, D.; Dhanasekaran, R.

    2006-01-01

    A three-dimensional numerical simulation study for the liquid phase electro epitaxial growth kinetic of GaAs is presented. The kinetic model is constructed considering (i) the diffusive and convective mass transport, (ii) the heat transfer due to thermoelectric effects such as Peltier effect, Joule effect and Thomson effect, (iii) the electric current distribution with electromigration and (iv) the fluid flow coupled with concentration and temperature fields. The simulations are performed for two configurations namely (i) epitaxial growth from the arsenic saturated gallium rich growth solution, i.e., limited solution model and (ii) epitaxial growth from the arsenic saturated gallium rich growth solution with polycrystalline GaAs feed. The governing equations of liquid phase electro epitaxy are solved numerically with appropriate initial and boundary conditions using the central difference method. Simulations are performed to determine the following, a concentration profiles of solute atoms (As) in the Ga-rich growth solution, shape of the substrate evolution, the growth rate of the GaAs epitaxial film, the contributions of Peltier effect and electromigration of solute atoms to the growth with various experimental growth conditions. The growth rate is found to increase with increasing growth temperature and applied current density. The results are discussed in detail

  1. Cadaveric and three-dimensional computed tomography study of the morphology of the scapula with reference to reversed shoulder prosthesis.

    Science.gov (United States)

    Torrens, Carlos; Corrales, Monica; Gonzalez, Gemma; Solano, Alberto; Cáceres, Enrique

    2008-10-10

    The purpose of this study is to analyze the morphology of the scapula with reference to the glenoid component implantation in reversed shoulder prosthesis, in order to improve primary fixation of the component. Seventy-three 3-dimensional computed tomography of the scapula and 108 scapular dry specimens were analyzed to determine the anterior and posterior length of the glenoid neck, the angle between the glenoid surface and the upper posterior column of the scapula and the angle between the major craneo-caudal glenoid axis and the base of the coracoid process and the upper posterior column. The anterior and posterior length of glenoid neck was classified into two groups named "short-neck" and "long-neck" with significant differences between them. The angle between the glenoid surface and the upper posterior column of the scapula was also classified into two different types: type I (mean 50 degrees-52 degrees ) and type II (mean 62.50 degrees-64 degrees ), with significant differences between them (p craneo-caudal glenoid axis and the base of the coracoid process averaged 18,25 degrees while the angle with the upper posterior column of the scapula averaged 8 degrees . Scapular morphological variability advices for individual adjustments of glenoid component implantation in reversed total shoulder prosthesis. Three-dimensional computed tomography of the scapula constitutes an important tool when planning reversed prostheses implantation.

  2. Cadaveric and three-dimensional computed tomography study of the morphology of the scapula with reference to reversed shoulder prosthesis

    Directory of Open Access Journals (Sweden)

    Solano Alberto

    2008-10-01

    Full Text Available Abstract Purpose The purpose of this study is to analyze the morphology of the scapula with reference to the glenoid component implantation in reversed shoulder prosthesis, in order to improve primary fixation of the component. Methods Seventy-three 3-dimensional computed tomography of the scapula and 108 scapular dry specimens were analyzed to determine the anterior and posterior length of the glenoid neck, the angle between the glenoid surface and the upper posterior column of the scapula and the angle between the major craneo-caudal glenoid axis and the base of the coracoid process and the upper posterior column. Results The anterior and posterior length of glenoid neck was classified into two groups named "short-neck" and "long-neck" with significant differences between them. The angle between the glenoid surface and the upper posterior column of the scapula was also classified into two different types: type I (mean 50°–52° and type II (mean 62,50°–64°, with significant differences between them (p Conclusion Scapular morphological variability advices for individual adjustments of glenoid component implantation in reversed total shoulder prosthesis. Three-dimensional computed tomography of the scapula constitutes an important tool when planning reversed prostheses implantation.

  3. Active immobilization of biomolecules on a hybrid three-dimensional nanoelectrode by dielectrophoresis for single-biomolecule study

    International Nuclear Information System (INIS)

    Yamamoto, Takatoki; Fujii, Teruo

    2007-01-01

    We propose and experimentally demonstrate a method of active immobilization for biomolecules on a three-dimensional nanometre-scale electrode (3D nanoelectrode) using dielectrophoresis to immobilize the biomolecules at predetermined locations for single-biomolecule study. We have developed a novel two-step fabrication process for obtaining a 3D nanoelectrode having a sharp top, which is necessary for immobilizing a single biomolecule at a single point. The first step is to fabricate the backbone structure, which is rigid and defines the shape of the 3D nanoelectrode. It was fabricated with diamond-like carbon (DLC) obtained using focused ion beam assisted chemical vapour deposition followed by post-plasma etching, which reshapes the DLC structure. The second step coats the DLC structure with a thin layer of aluminium, which supplies electrical conductivity to the DLC structure. By applying a high frequency (of the order of megahertz) and high intensity (greater than or equal to a few megavolts per metre) electric field using the 3D nanoelectrodes, the generated dielectrophoresis attracted and then immobilized target biomolecules onto the tops of 3D nanoelectrodes, as a demonstration of active immobilization of biomolecules

  4. Dynamic time-dependent analysis and static three-dimensional imaging procedures for computer-assisted CNS studies

    International Nuclear Information System (INIS)

    Budinger, T.F.; DeLand, F.H.; Duggan, H.E.; Bouz, J.J.; Hoop, B. Jr.; McLaughlin, W.T.; Weber, P.M.

    1975-01-01

    Two-dimensional computer image-processing techniques have not proved to be of importance in diagnostic nuclear medicine primarily because the radionuclide distribution represents a three-dimensional problem. More recent developments in three-dimensional reconstruction from multiple views or multiple detectors promise to overcome the major limitations in previous work with digital computers. These techniques are now in clinical use for static imaging; however, speed limitations have prevented application to dynamic imaging. The future development of these methods will require innovations in patient positioning and multiple-view devices for either single-gamma or positron annihilation detection

  5. Three-dimensional echocardiography in various types of heart disease: a comparison study of magnetic resonance imaging and 64-slice computed tomography in a real-world population.

    Science.gov (United States)

    Squeri, Angelo; Censi, Stefano; Reverberi, Claudio; Gaibazzi, Nicola; Baldelli, Marco; Binno, Simone Maurizio; Properzi, Enrico; Bosi, Stefano

    2017-03-01

    Accurate quantification of left ventricular (LV) volumes [end-diastolic volume (EDV) and end-systolic volume (ESV)] and ejection fraction (EF) is of critical importance. The development of real-time three-dimensional echocardiography (RT3DE) has shown better correlation than two-dimensional (2D) echocardiography with magnetic resonance imaging (MRI) measurements. The aim of our study was to assess the accuracy of RT3DE and 64-slice computed tomography (CT) in the evaluation of LV volumes and function using MRI as the reference standard in a real-world population with various types of heart disease with different chamber geometry. The study population consisted of 66 patients referred for cardiac MRI for various pathologies. All patients underwent cardiac MRI, and RT3DE and 64 slices CT were then performed on a subsequent day. The study population was then divided into 5 clinical groups depending on the underlying heart disease. RT3DE volumes correlated well with MRI values (R 2 values: 0.90 for EDV and 0.94 for ESV). RT3DE measurements of EF correlated well with MRI values (R 2  = 0.86). RT3DE measurements resulted in slightly underestimated values of both EDV and ESV, as reflected by biases of -9.18 and -4.50 mL, respectively. Comparison of RT3DE and MRI in various types of cardiomyopathies showed no statistical difference between different LV geometrical patterns. These results confirm that RT3DE has good accuracy in everyday clinical practice and can be of clinical utility in all types of cardiomyopathy independently of LV geometric pattern, LV diameter or wall thickness, taking into account a slight underestimation of LV volumes and EF compared to MRI.

  6. Two-dimensional versus three-dimensional CT angiography in analysis of anatomical suitability for stentgraft repair of abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    Pitoulias, Georgios A.; Aslanidou, Eleni A.; Papadimitriou, Dimitrios K.; Donas, Konstantinos P.; Schulte, Stefan

    2011-01-01

    Background The morphological analysis prior to endovascular abdominal aneurysm repair (EVAR) plays an important role in long-term outcomes. Post-imaging analysis of computed tomographic angiography (CTA) by three-dimensional reconstruction with central lumen line detection (CLL 3D-CTA) enables measurements to be made in orthogonal slices. This might be more precise than equal post-imaging analysis in axial slices by two-dimensional computed tomographic angiography (2D-CTA). Purpose To evaluate the intra- and interobserver variability of CLL 3D-CTA and 2D-CTA post-imaging analysis methods and the agreement between them in pre-EVAR suitability analysis of patients with abdominal aortic aneurysm (AAA). Material and Methods Anonymized CTA data-sets from 70 patients with AAA were analyzed retrospectively. Length measurements included proximal and distal aortic neck lengths and total distance from the lower renal artery to the higher iliac bifurcation. Width measurements included proximal and distal neck diameters, maximum AAA diameter and common iliac diameters just above the iliac bifurcations. The measurements were performed in random order by two vascular surgeons, twice per method with 1-month interval between readings. In the CLL 3D-CTA method we used semi-automated CLL detection by software and manual measurements on CTA slices perpendicular to CLL. The equal measurements in 2D-CTA were performed manually on axial CTA slices using a DICOM viewer workstation. The intra- and interobserver variability, as well as the agreement between the two methods were assessed by Bland-Altman test and bivariate correlation analysis. Results The intraobserver variability was significantly higher in 2D-CTA measurements for both readers. The interobserver variability was significant in 2D-CTA measurements of proximal neck dimensions while the agreement in CLL 3D-CTA analysis between the two readers was excellent in all studied parameters. The agreement between the two suitability

  7. [Study on the geometric characteristics and distribution of porosities in three-dimensional printed Ti-6Al-4V titanium alloy].

    Science.gov (United States)

    Wan, Zhipeng; Jiang, Wentao; Wang, Chong; Wang, Qingyuan; Li, Yalan

    2017-10-01

    Three dimensional (3D) printing is considered as an advanced manufacturing technology because of its additive nature. Electron beam melting (EBM) is a widely used 3D printing processes for the manufacturing of metal components. However, the products printed via this process generally contain micro porosities which affect mechanical properties, especially the fatigue property. In this paper, two types of EBM printed samples of the Ti-6Al-4V alloy, one with a round cross section and the other with a triangle cross section, were employed to investigate the existence of porosities using computed tomography (CT). Statistical analyses were conducted on the number, volume, shape, and distribution of pores. The results show that small pores (less than 0.000 2 mm 3 ) account for 80% of all pores in each type of samples. Additionally, to some extent, the shape of sample has influence on the number of micro porosities in EBM made Ti-6Al-4V. The sphericity of the pores is relatively low and is inversely proportional to pore volume. It is found that re-melting on the free surface effectively reduce pore density near the surface. This study may help produce a medical implant with better fatigue resistance.

  8. Three-dimensional technology for linear morphological studies: a re-examination of cranial variation in four southern African indigenous populations.

    Science.gov (United States)

    Franklin, D; Freedman, L; Milne, N

    2005-01-01

    In order to compare linear dimensions made by traditional anthropometric techniques, and those obtained from three-dimensional coordinates, samples of four indigenous southern African populations were analysed. Linear measurements were obtained using mathematically transformed, three-dimensional landmark data on 207 male crania of Cape Nguni, Natal Nguni, Sotho and Shangaan. Univariate comparisons for accuracy of the transformed linear data were made with those in a traditional linear study by de Villiers (The Skull of the South African Negro: A Biometrical and Morphological Study. Witwatersrand University Press, Johannesburg) on similar samples and equivalent landmarks. Comparisons were not made with her Penrose (Ann Eugenics 18 (1954) 337) analysis as an apparently anomalous 'shape'-'size' statistic was found. The univariate comparisons demonstrated that accurate linear measurements could be derived from three-dimensional data, showing that it is possible to simultaneously obtain data for three-dimensional geometric 'shape' and linear interlandmark analyses. Using Penrose and canonical variates analyses of the transformed three-dimensional interlandmark measurements, similar population distances were found for the four indigenous southern African populations. The inter-population distance relationships took the form of three separated pairs of distances, with the within-pair distances very similar in size. The cranial features of the four populations were found to be overall very similar morphometrically. However the populations were each shown by CVA to have population specific features, and using discriminant analyses 50% or more of the individual crania (with the exception of the Sotho) could be referred to their correct populations.

  9. Three-dimensional modeling of subsurface contamination: A case study from the radio frequency-heating demonstration at the Savannah River Site

    International Nuclear Information System (INIS)

    Poppy, S.P.; Eddy-Dilek, C.A.; Jarosch, T.R.

    1994-01-01

    Computer based three-dimensional modeling is a powerful tool used for visualizing and interpreting environmental data collected at the Savannah River Site (SRS). Three-dimensional modeling was used to image and interpret subsurface spatial data, primarily, changes in the movement, the accumulation, and the depletion of contaminants at the Integrated Demonstration Site (IDS), a proving ground for experimental environmental remediation technologies. Three-dimensional models are also educational tools, relaying complex environmental data to interested non-technical individuals who may be unfamiliar with the concepts and terminology involved in environmental studies. The public can draw their own conclusions of the success of the experiments after viewing the three-dimensional images set up in a chronological order. The three-dimensional grids generated during these studies can also be used to create images for visualization and animated sequences that model contamination movement. Animation puts the images of contamination distribution in motion and results in a new perspective on the effects of the remedial demonstration

  10. Study of structural attachments of a pool type LMFBR vessel through seismic analysis of a simplified three dimensional finite element model

    International Nuclear Information System (INIS)

    Ahmed, H.; Ma, D.

    1979-01-01

    A simplified three dimensional finite element model of a pool type LMFBR in conjunction with the computer program ANSYS is developed and scoping results of seismic analysis are produced. Through this study various structural attachments of a pool type LMFBR like the reactor vessel skirt support, the pump support and reactor shell-support structure interfaces are studied. This study also provides some useful results on equivalent viscous damping approach and some improvements to the treatment of equivalent viscous damping are recommended. This study also sets forth pertinent guidelines for detailed three dimensional finite element seismic analysis of pool type LMFBR

  11. A three-dimensional cell culture model to study the mechano-biological behavior in periodontal ligament regeneration

    NARCIS (Netherlands)

    Oortgiesen, D.A.W.; Yu, N.; Bronckers, A.L.J.J.; Yang, F.; Walboomers, X.F.; Jansen, J.A.

    2012-01-01

    Periodontitis is a disease affecting the supporting structures of the teeth, which can eventually result in tooth loss. A three-dimensional (3D) tissue culture model was developed that may serve to grow a 3D construct that not only transplants into defective periodontal sites, but also allows to

  12. CT two-dimensional reformation versus three-dimensional volume rendering with regard to surgical findings in the preoperative assessment of the ossicular chain in chronic suppurative otitis media

    International Nuclear Information System (INIS)

    Guo, Yong; Liu, Yang; Lu, Qiao-hui; Zheng, Kui-hong; Shi, Li-jing; Wang, Qing-jun

    2013-01-01

    Purpose: To assess the role of three-dimensional volume rendering (3DVR) in the preoperative assessment of the ossicular chain in chronic suppurative otitis media (CSOM). Materials and methods: Sixty-six patients with CSOM were included in this prospective study. Temporal bone was scanned with a 128-channel multidetector row CT and the axial data was transferred to the workstation for multiplanar reformation (MPR) and 3DVR reconstructions. Evaluation of the ossicular chain according to a three-point scoring system on two-dimensional reformation (2D) and 3DVR was performed independently by two radiologists. The evaluation results were compared with surgical findings. Results: 2D showed over 89% accuracy in the assessment of segmental absence of the ossicular chain in CSOM, no matter how small the segmental size was. 3DVR was as accurate as 2D for the assessment of segmental absence. However, 3DVR was found to be more accurate than 2D in the evaluation of partial erosion of segments. Conclusion: Both 3DVR and 2D are accurate and reliable for the assessment of the ossicular chain in CSOM. The inclusion of 3DVR images in the imaging protocol improves the accuracy of 2D in detecting ossicular erosion from CSOM

  13. CT two-dimensional reformation versus three-dimensional volume rendering with regard to surgical findings in the preoperative assessment of the ossicular chain in chronic suppurative otitis media

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Yong, E-mail: guoyong27@hotmail.com [Department of Radiology, Navy General Hospital, 6# Fucheng Road, Beijing 100048 (China); Liu, Yang, E-mail: liuyangdoc@sina.com [Department of Otorhinolaryngology, Navy General Hospital, 6# Fucheng Road, Beijing 100048 (China); Lu, Qiao-hui, E-mail: Luqiaohui465@126.com [Department of Radiology, Navy General Hospital, 6# Fucheng Road, Beijing 100048 (China); Zheng, Kui-hong, E-mail: zhengkuihong1971@sina.com [Department of Radiology, Navy General Hospital, 6# Fucheng Road, Beijing 100048 (China); Shi, Li-jing, E-mail: Shilijing2003@yahoo.com.cn [Department of Radiology, Navy General Hospital, 6# Fucheng Road, Beijing 100048 (China); Wang, Qing-jun, E-mail: wangqingjun77@163.com [Department of Radiology, Navy General Hospital, 6# Fucheng Road, Beijing 100048 (China)

    2013-09-15

    Purpose: To assess the role of three-dimensional volume rendering (3DVR) in the preoperative assessment of the ossicular chain in chronic suppurative otitis media (CSOM). Materials and methods: Sixty-six patients with CSOM were included in this prospective study. Temporal bone was scanned with a 128-channel multidetector row CT and the axial data was transferred to the workstation for multiplanar reformation (MPR) and 3DVR reconstructions. Evaluation of the ossicular chain according to a three-point scoring system on two-dimensional reformation (2D) and 3DVR was performed independently by two radiologists. The evaluation results were compared with surgical findings. Results: 2D showed over 89% accuracy in the assessment of segmental absence of the ossicular chain in CSOM, no matter how small the segmental size was. 3DVR was as accurate as 2D for the assessment of segmental absence. However, 3DVR was found to be more accurate than 2D in the evaluation of partial erosion of segments. Conclusion: Both 3DVR and 2D are accurate and reliable for the assessment of the ossicular chain in CSOM. The inclusion of 3DVR images in the imaging protocol improves the accuracy of 2D in detecting ossicular erosion from CSOM.

  14. Computerized three-dimensional normal atlas

    International Nuclear Information System (INIS)

    Mano, Isamu; Suto, Yasuzo; Suzuki, Masataka; Iio, Masahiro.

    1990-01-01

    This paper presents our ongoing project in which normal human anatomy and its quantitative data are systematically arranged in a computer. The final product, the Computerized Three-Dimensional Normal Atlas, will be able to supply tomographic images in any direction, 3-D images, and coded information on organs, e.g., anatomical names, CT numbers, and T 1 and T 2 values. (author)

  15. Toxicology studies of primycin-sulphate using a three-dimensional (3D) in vitro human liver aggregate model.

    Science.gov (United States)

    Pénzes, Ágota; Mahmud Abdelwahab, Elhusseiny Mohamed; Rapp, Judit; Péteri, Zsanett A; Bovári-Biri, Judit; Fekete, Csaba; Miskei, György; Kvell, Krisztián; Pongrácz, Judit E

    2017-11-05

    Primycin-sulphate is a highly effective compound against Gram (G) positive bacteria. It has a potentially synergistic effect with vancomycin and statins which makes primycin-sulphate a potentially very effective preparation. Primycin-sulphate is currently used exclusively in topical preparations. In vitro animal hepatocyte and neuromuscular junction studies (in mice, rats, snakes, frogs) as well as in in vitro human red blood cell experiments were used to test toxicity. During these studies, the use of primycin-sulphate resulted in reduced cellular membrane integrity and modified ion channel activity. Additionally, parenteral administration of primycin-sulphate to mice, dogs, cats, rabbits and guinea pigs indicated high level of acute toxicity. The objective of this study was to reveal the cytotoxic and gene expression modifying effects of primycin-sulphate in a human system using an in vitro, three dimensional (3D) human hepatic model system. Within the 3D model, primycin-sulphate presented no acute cytotoxicity at concentrations 1μg/ml and below. However, even at low concentrations, primycin-sulphate affected gene expressions by up-regulating inflammatory cytokines (e.g., IL6), chemokines (e.g., CXCL5) and by down-regulating molecules of the lipid metabolism (e.g., peroxisome proliferator receptor (PPAR) alpha, gamma, etc). Down-regulation of PPAR alpha cannot just disrupt lipid production but can also affect cytochrome P450 metabolic enzyme (CYP) 3A4 expression, highlighting the need for extensive drug-drug interaction (DDI) studies before human oral or parenteral preparations can be developed. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Three-dimensional DFN Model Development and Calibration: A Case Study for Pahute Mesa, Nevada National Security Site

    Science.gov (United States)

    Pham, H. V.; Parashar, R.; Sund, N. L.; Pohlmann, K.

    2017-12-01

    Pahute Mesa, located in the north-western region of the Nevada National Security Site, is an area where numerous underground nuclear tests were conducted. The mesa contains several fractured aquifers that can potentially provide high permeability pathways for migration of radionuclides away from testing locations. The BULLION Forced-Gradient Experiment (FGE) conducted on Pahute Mesa injected and pumped solute and colloid tracers from a system of three wells for obtaining site-specific information about the transport of radionuclides in fractured rock aquifers. This study aims to develop reliable three-dimensional discrete fracture network (DFN) models to simulate the BULLION FGE as a means for computing realistic ranges of important parameters describing fractured rock. Multiple conceptual DFN models were developed using dfnWorks, a parallelized computational suite developed by Los Alamos National Laboratory, to simulate flow and conservative particle movement in subsurface fractured rocks downgradient from the BULLION test. The model domain is 100x200x100 m and includes the three tracer-test wells of the BULLION FGE and the Pahute Mesa Lava-flow aquifer. The model scenarios considered differ from each other in terms of boundary conditions and fracture density. For each conceptual model, a number of statistically equivalent fracture network realizations were generated using data from fracture characterization studies. We adopt the covariance matrix adaptation-evolution strategy (CMA-ES) as a global local stochastic derivative-free optimization method to calibrate the DFN models using groundwater levels and tracer breakthrough data obtained from the three wells. Models of fracture apertures based on fracture type and size are proposed and the values of apertures in each model are estimated during model calibration. The ranges of fracture aperture values resulting from this study are expected to enhance understanding of radionuclide transport in fractured rocks and

  17. Study on Ti-6Al-4V Alloy Machining Applying the Non-Resonant Three-Dimensional Elliptical Vibration Cutting

    Directory of Open Access Journals (Sweden)

    Mingming Lu

    2017-10-01

    Full Text Available The poor machinability of Ti-6Al-4V alloy makes it hard to process by conventional processing methods even though it has been widely used in military and civilian enterprise fields. Non-resonant three-dimensional elliptical vibration cutting (3D-EVC is a novel cutting technique which is a significant development potential for difficult-to-cut materials. However, few studies have been conducted on processing the Ti-6Al-4V alloy using the non-resonant 3D-EVC technique, the effect of surface quality, roughness, topography and freeform surface has not been clearly researched yet. Therefore, the machinability of Ti-6Al-4V alloy using the non-resonant 3D-EVC apparatus is studied in this paper. Firstly, the principle of non-resonant 3D-EVC technique and the model of cutter motion are introduced. Then the tool path is synthesized. The comparison experiments are carried out with traditional continuous cutting (TCC, two-dimension elliptical vibration cutting (2D-EVC, and the non-resonant 3D-EVC method. The experimental results shown that the excellent surface and lower roughness (77.3 nm could be obtained using the non-resonant 3D-EVC method; the shape and dimension of elliptical cutting mark also relates to the cutting speed and vibration frequency, and the concave/convex spherical surface topography are achieved by non-resonant 3D-EVC in the Ti-6Al-4V alloy. This proved that the non-resonant 3D-EVC technique has the better machinability compared with the TCC and 2D-EVC methods.

  18. Three-dimensional regional strain analysis in porcine myocardial infarction: a 3T magnetic resonance tagging study

    Directory of Open Access Journals (Sweden)

    Soleimanifard Sahar

    2012-12-01

    Full Text Available Abstract Background Previous studies of mechanical strain anomalies in myocardial infarction (MI have been largely limited to analysis of one-dimensional (1D and two-dimensional (2D strain parameters. Advances in cardiovascular magnetic resonance (CMR methods now permit a complete three-dimensional (3D interrogation of myocardial regional strain. The aim of this study was to investigate the incremental value of CMR-based 3D strain and to test the hypothesis that 3D strain is superior to 1D or 2D strain analysis in the assessment of viability using a porcine model of infarction. Methods Infarction was induced surgically in 20 farm pigs. Cine, late gadolinium enhancement, and CMR tagging images were acquired at 11 days before (baseline, and 11 days (early and 1 month (late after induction of infarct. Harmonic phase analysis was performed to measure circumferential, longitudinal, and radial strains in myocardial segments, which were defined based on the transmurality of delayed enhancement. Univariate, bivariate, and multivariate logistic regression models of strain parameters were created and analyzed to compare the overall diagnostic accuracy of 3D strain analysis with 1D and 2D analyses in identifying the infarct and its adjacent regions from healthy myocardium. Results 3D strain differed significantly in infarct, adjacent, and remote segments (p  Conclusions Cumulative 3D strain information accurately identifies infarcts and their neighboring regions from healthy myocardium. The 3D interrogation of myocardial contractility provides incremental diagnostic accuracy in delineating the dysfunctional and nonviable myocardium in comparison with 1D or 2D quantification of strain. The infarct neighboring regions are the major beneficiaries of the 3D assessment of regional strain.

  19. Efficacy of transpalatal arch as an anchorage reinforcing unit during orthodontic space closure: A three-dimensional finite element study

    Directory of Open Access Journals (Sweden)

    Vishal Shrishail Kudagi

    2017-01-01

    Full Text Available Background and Objectives: Connecting the contralateral upper molars by means of a transpalatal arch (TPA is thought to decrease the tendency of the molars to move mesially in response to orthodontic force (i.e., provide orthodontic anchorage. This study was hence conducted to investigate the effects of the TPA on the displacement of the molars and stresses generated in the periodontium during orthodontic tooth movement using the finite element method (FEM. Materials and Methods: A three-dimensional (3D model was generated using medical modeling software (Mimics using the computed tomography slice images of the skull which were obtained at a slice thickness of 1 mm. From this, the finite element model was built using HyperMesh and analysis was performed using PATRAN software (MSC Software Corporation, 4675 MacArthur Court, Newport Beach, California 92660. The 3D finite element models were fabricated in two versions such as maxillary first molars including their associated periodontal ligament and alveolar bone one with TPA and another without TPA. Both were subjected to orthodontic forces, and the resultant stress patterns and displacements between the models with and without TPA were determined. Results: The stress and displacement plots in this study failed to show any significant differences in stress and displacement within the periodontium of molars, between the two models – one with TPA and the other without, in response to the orthodontic force. Interpretation and Conclusion: The results of the current finite element analysis, therefore, suggest that the presence of a TPA brings about no change in the initial dental and periodontal stress distribution and displacement.

  20. Two iridates, two models, and two approaches: A comparative study on magnetism in three-dimensional honeycomb materials

    Science.gov (United States)

    Lee, Eric Kin-Ho; Rau, Jeffrey G.; Kim, Yong Baek

    2016-05-01

    Two recent theoretical works studied the role of Kitaev interactions in the newly observed incommensurate magnetic order in the hyper-honeycomb (β -Li2IrO3 ) and stripy-honeycomb (γ -Li2IrO3 ) iridates. Each of these works analyzed a different model (J K Γ versus coupled zigzag chain model) using a contrasting method (classical versus soft-spin analysis). The lack of commonality between these works precludes meaningful comparisons and a proper understanding of these unusual orderings. In this study, we complete the unfinished picture initiated by these two works by solving both models with both approaches for both three-dimensional (3D) honeycomb iridates. Through comparisons between all combinations of models, techniques, and materials, we find that the bond-isotropic J K Γ model consistently predicts the experimental phase of β -Li2IrO3 regardless of the method used, while the experimental phase of γ -Li2IrO3 can be generated by the soft-spin approach with eigenmode mixing irrespective of the model used. To gain further insights, we solve a one-dimensional (1D) quantum spin-chain model related to both 3D models using the density matrix renormalization group method to form a benchmark. We discover that in the 1D model, incommensurate correlations in the classical and soft-spin analysis survive in the quantum limit only in the presence of the symmetric-off-diagonal exchange Γ found in the J K Γ model. The relevance of these results to the real materials is also discussed.

  1. Three-dimensional planning and use of patient-specific guides improve glenoid component position: an in vitro study.

    Science.gov (United States)

    Walch, Gilles; Vezeridis, Peter S; Boileau, Pascal; Deransart, Pierric; Chaoui, Jean

    2015-02-01

    Glenoid component positioning is a key factor for success in total shoulder arthroplasty. Three-dimensional (3D) measurements of glenoid retroversion, inclination, and humeral head subluxation are helpful tools for preoperative planning. The purpose of this study was to assess the reliability and precision of a novel surgical method for placing the glenoid component with use of patient-specific templates created by preoperative surgical planning and 3D modeling. A preoperative computed tomography examination of cadaveric scapulae (N = 18) was performed. The glenoid implants were virtually placed, and patient-specific guides were created to direct the guide pin into the desired orientation and position in the glenoid. The 3D orientation and position of the guide pin were evaluated by performing a postoperative computed tomography scan for each scapula. The differences between the preoperative planning and the achieved result were analyzed. The mean error in 3D orientation of the guide pin was 2.39°, the mean entry point position error was 1.05 mm, and the mean inclination angle error was 1.42°. The average error in the version angle was 1.64°. There were no technical difficulties or complications related to use of patient-specific guides for guide pin placement. Quantitative analysis of guide pin positioning demonstrated a good correlation between preoperative planning and the achieved position of the guide pin. This study demonstrates the reliability and precision of preoperative planning software and patient-specific guides for glenoid component placement in total shoulder arthroplasty. Copyright © 2015. Published by Elsevier Inc.

  2. Three-dimensional development of tensile pre-strained annulus fibrosus cells for tissue regeneration: An in-vitro study

    Energy Technology Data Exchange (ETDEWEB)

    Chuah, Yon Jin [School of Chemical and Biomedical Engineering, Nanyang Technological University, 62 Nanyang Drive, Singapore 637459 (Singapore); Lee, Wu Chean [University Hospital Conventry & Warwickshire NHS Trust, Clifford Bridge Road, West Midlands CV2, 2DX (United Kingdom); Wong, Hee Kit [Department of Orthopedic Surgery, National University Health System, NUHS Tower Block Level 11, 1E Kent Ridge Road, Singapore 119228 (Singapore); Kang, Yuejun, E-mail: yuejun.kang@ntu.edu.sg [School of Chemical and Biomedical Engineering, Nanyang Technological University, 62 Nanyang Drive, Singapore 637459 (Singapore); Hee, Hwan Tak, E-mail: HTHee@ntu.edu.sg [School of Chemical and Biomedical Engineering, Nanyang Technological University, 62 Nanyang Drive, Singapore 637459 (Singapore); Pinnacle Spine & Scoliosis Centre, 3 Mount Elizabeth, Mount Elizabeth Medical Centre, #04-07, Singapore 228510 (Singapore); School of Physical and Mathematical Sciences, Nanyang Technological University, 21 Nanyang Link, Singapore 637459 (Singapore)

    2015-02-01

    Prior research has investigated the immediate response after application of tensile strain on annulus fibrosus (AF) cells for the past decade. Although mechanical strain can produce either catabolic or anabolic consequences to the cell monolayer, little is known on how to translate these findings into further tissue engineering applications. Till to date, the application and effect of tensile pre-strained cells to construct a three-dimensional (3D) AF tissue remains unknown. This study aims to investigate the effect of tensile pre-strained exposure of 1 to 24 h on the development of AF pellet culture for 3 weeks. Equibiaxial cyclic tensile strain was applied on AF monolayer cells over a period of 24 h, which was subsequently developed into a cell pellet. Investigation on cellular proliferation, phenotypic gene expression, and histological changes revealed that tensile pre-strain for 24 h had significant and lasting effect on the AF tissue development, with enhanced cell proliferation, and up-regulation of collagen type I, II, and aggrecan expression. Our results demonstrated the regenerative ability of AF cell pellets subjected to 24 h tensile pre-straining. Knowledge on the effects of tensile pre-strain exposure is necessary to optimize AF development for tissue reconstruction. Moreover, the tensile pre-strained cells may further be utilized in either cell therapy to treat mild disc degeneration disease, or the development of a disc construct for total disc replacement. - Highlights: • Establishment of tensile pre-strained cell line population for annulus development. • Tensile strain limits collagen gene expression declination in monolayer culture. • Tensile pre-strained cells up-regulate their matrix protein in 3D pellet culture.

  3. Two-Dimensional High Definition Versus Three-Dimensional Endoscopy in Endonasal Skull Base Surgery: A Comparative Preclinical Study.

    Science.gov (United States)

    Rampinelli, Vittorio; Doglietto, Francesco; Mattavelli, Davide; Qiu, Jimmy; Raffetti, Elena; Schreiber, Alberto; Villaret, Andrea Bolzoni; Kucharczyk, Walter; Donato, Francesco; Fontanella, Marco Maria; Nicolai, Piero

    2017-09-01

    Three-dimensional (3D) endoscopy has been recently introduced in endonasal skull base surgery. Only a relatively limited number of studies have compared it to 2-dimensional, high definition technology. The objective was to compare, in a preclinical setting for endonasal endoscopic surgery, the surgical maneuverability of 2-dimensional, high definition and 3D endoscopy. A group of 68 volunteers, novice and experienced surgeons, were asked to perform 2 tasks, namely simulating grasping and dissection surgical maneuvers, in a model of the nasal cavities. Time to complete the tasks was recorded. A questionnaire to investigate subjective feelings during tasks was filled by each participant. In 25 subjects, the surgeons' movements were continuously tracked by a magnetic-based neuronavigator coupled with dedicated software (ApproachViewer, part of GTx-UHN) and the recorded trajectories were analyzed by comparing jitter, sum of square differences, and funnel index. Total execution time was significantly lower with 3D technology (P < 0.05) in beginners and experts. Questionnaires showed that beginners preferred 3D endoscopy more frequently than experts. A minority (14%) of beginners experienced discomfort with 3D endoscopy. Analysis of jitter showed a trend toward increased effectiveness of surgical maneuvers with 3D endoscopy. Sum of square differences and funnel index analyses documented better values with 3D endoscopy in experts. In a preclinical setting for endonasal skull base surgery, 3D technology appears to confer an advantage in terms of time of execution and precision of surgical maneuvers. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Annular dynamics after mitral valve repair with different prosthetic rings: A real-time three-dimensional transesophageal echocardiography study.

    Science.gov (United States)

    Nishi, Hiroyuki; Toda, Koichi; Miyagawa, Shigeru; Yoshikawa, Yasushi; Fukushima, Satsuki; Kawamura, Masashi; Yoshioka, Daisuke; Saito, Tetsuya; Ueno, Takayoshi; Kuratani, Toru; Sawa, Yoshiki

    2016-09-01

    We assessed the effects of different types of prosthetic rings on mitral annular dynamics using real-time three-dimensional echocardiography (RT3DE). RT3DE was performed in 44 patients, including patients undergoing mitral annuloplasty using the Cosgrove-Edwards flexible band (Group A, n = 10), the semi-rigid Sorin Memo 3D ring (Group B, n = 17), the semi-rigid Edwards Physio II ring (Group C, n = 7) and ten control subjects. Various annular diameters were measured throughout the cardiac cycle. We observed flexible anterior annulus motion in all of the groups except Group C. A flexible posterior annulus was only observed in Group B and the Control group. The mitral annular area changed during the cardiac cycle by 8.4 ± 3.2, 6.3 ± 2.0, 3.2 ± 1.3, and 11.6 ± 5.0 % in Group A, Group B, Group C, and the Control group, respectively. The dynamic diastolic to systolic change in mitral annular diameters was lost in Group C, while it was maintained in Group A, and to a good degree in Group B. In comparison to the Control group, the mitral annulus shape was more ellipsoid in Group B and Group C, and more circular in Group A. Although mitral regurgitation was well controlled by all of the types of rings that were utilized in the present study, we demonstrated that the annulus motion and annulus shape differed according to the type of prosthetic ring that was used, which might provide important information for the selection of an appropriate prosthetic ring.

  5. A three-dimensional finite element study on the stress distribution pattern of two prosthetic abutments for external hexagon implants.

    Science.gov (United States)

    Moreira, Wagner; Hermann, Caio; Pereira, Jucélio Tomás; Balbinoti, Jean Anacleto; Tiossi, Rodrigo

    2013-10-01

    The purpose of this study was to evaluate the mechanical behavior of two different straight prosthetic abutments (one- and two-piece) for external hex butt-joint connection implants using three-dimensional finite element analysis (3D-FEA). Two 3D-FEA models were designed, one for the two-piece prosthetic abutment (2 mm in height, two-piece mini-conical abutment, Neodent) and another one for the one-piece abutment (2 mm in height, Slim Fit one-piece mini-conical abutment, Neodent), with their corresponding screws and implants (Titamax Ti, 3.75 diameter by 13 mm in length, Neodent). The model simulated the single restoration of a lower premolar using data from a computerized tomography of a mandible. The preload (20 N) after torque application for installation of the abutment and an occlusal loading were simulated. The occlusal load was simulated using average physiological bite force and direction (114.6 N in the axial direction, 17.1 N in the lingual direction and 23.4 N toward the mesial at an angle of 75° to the occlusal plan). The regions with the highest von Mises stress results were at the bottom of the initial two threads of both prosthetic abutments that were tested. The one-piece prosthetic abutment presented a more homogeneous behavior of stress distribution when compared with the two-piece abutment. Under the simulated chewing loads, the von Mises stresses for both tested prosthetic-abutments were within the tensile strength values of the materials analyzed which thus supports the clinical use of both prosthetic abutments.

  6. Two-dimensional color Doppler echocardiography for left ventricular stroke volume assessment: a comparison study with three-dimensional echocardiography.

    Science.gov (United States)

    Silva, Cristina Da; Pedro, Fátima; Deister, Lizandra; Sahlén, Anders; Manouras, Aristomenis; Shahgaldi, Kambiz

    2012-08-01

    Whether measurement of left ventricular outflow tract diameter (LVOTd) using color Doppler (CD) in order to more accurately define LVOTd is more accurate for determination of stroke volume (SV) than gray scale and compare it with direct measurement of LVOT area (a) using three-dimensional echocardiography (3DE) for SV determination. Twenty-one volunteers were examined. LVOTa was calculated by two-dimensional echocardiography (2DE) using the following formula: π× (d/2)(2) , d = LVOT diameter by gray scale and CD, respectively. Planimetry of LVOTa was performed in parasternal long axis using 3DE. Eccentricity Index was calculated using the lateral and anterior-posterior LVOTd. SV was obtained by four different methods: (1) 2D gray scale, (2) 2D color, (3) LVOTa × LVOT velocity time integral, and (4) SV by Simpson's biplane method. Gray scale LVOTd was significantly smaller compared to LVOTd obtained with CD (P vs 3.67 ± 0.70 cm(2) , P vs 3.61 ± 0.89 cm(2) , P = 0.011). Half of the subjects had at least 17% difference between the lateral and anterior-posterior LVOTd. There were significant differences between SV by 2D gray scale and 2D CD (82.8 ± 17.1 mL vs 92.4 ± 16.8 mL, P vs 90.7 ± 19.8 mL, P = 0.025). Our study demonstrates LVOT being frequently elliptical. SV and LVOTa were found to be similar when comparing 2DE CD and 3DE planimetry and showed higher values in comparison to 2DE gray scale, which suggests 2DE CD to be an alternative approach for SV assessment. © 2012, Wiley Periodicals, Inc.

  7. Finite element study of three dimensional radiative nano-plasma flow subject to Hall and ion slip currents

    Directory of Open Access Journals (Sweden)

    M. Nawaz

    Full Text Available In this article, we developed a computer code of Galerikan Finite Element method (GFEM for three dimensional flow equations of nano-plasma fluid (blood in the presence of uniform applied magnetic field when Hall and ion slip current are significant. Lorentz force is calculated through generalized Ohm’s law with Maxwell equations. A series of numerical simulations are carried out to search ηmax and algebraic equations are solved by Gauss-Seidel method with simulation tolerance 10-8. Simulated results for special case have an excellent agreement with the already published results. Velocity components and temperature of the nano-plasma (blood are influenced significantly by the inclusion of nano-particles of Copper (Cu and Silver (Ag. Heat enhancement is observed when copper and silver nonmagnetic nanoparticles are used instead of simple base fluid (conventional fluid. Radiative nature of nano-plasma in the presence of magnetic field causes a decrease in the temperature due to the transfer of heat by the electromagnetic waves. In contrast to this, due to heat dissipated by Joule heating and viscous dissipation phenomena, temperature of nano-plasmaincreases as thermal radiation parameter is increased. Thermal boundary layer thickness can be controlled by using radiative fluid instead of non-radiative fluid. Momentum boundary layer thickness can be reduced by increasing the intensity of the applied magnetic field. Temperature of plasma in the presence magnetic field is higher than the plasma in the absence of magnetic field. Keywords: Nanofluid, Grid independent study, Convergence, Error analysis, Skin friction, Joule heating, Viscous dissipation, Hall and ion currents

  8. Three dimensional MEMS supercapacitors

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Wei

    2011-10-15

    The overall objective of this research is to achieve compact supercapacitors with high capacitance, large power density, and long cycle life for using as micro power sources to drive low power devices and sensors. The main shortcoming of supercapacitors as a power source is that its energy density typically is about 1/10 of that of batteries. To achieve compact supercapacitors of large energy density, supercapacitors must be developed with high capacitance and power density which are mainly depended on the effective surface area of the electrodes of the supercapacitors. Many studies have been done to increase the effective surface area by modifying the electrode materials, however, much less investigations are focus on machining the electrodes. In my thesis work, micro- and nano-technologies are applied as technology approaches for machining the electrodes with three dimensional (3D) microstructures. More specific, Micro-electro-mechanical system (MEMS) fabrication process flow, which integrates the key process such as LIGA-like (German acronym for Lithographie, Galvanoformung, Abformung, which mean Lithography, Electroplating and Molding) technology or DRIE (deep reactive ion etching), has been developed to enable innovative designs of 3D MEMS supercapacitors which own the electrodes of significantly increased geometric area. Two types of 3D MEMS supercapcitors, based on LIGA-like and DRIE technology respectively, were designed and successfully created. The LIGA-like based 3D MEMS supercapacitor is with an interdigital 3D structure, and consists of silicon substrate, two electroplated nickel current collectors, two PPy (poly pyrrole) electrodes, and solid state electrolyte. The fabrication process flow developed includes the flowing key processes, SU-8 lithography, nickel electroplating, PPy polymerization and solid state electrolyte coating. Electrochemical tests showed that the single electrode of the supercapacitor has the specific capacitance of 0.058 F cm-2

  9. Segmental analysis of cochlea on three-dimensional MR imaging and high-resolution CT. Application to pre-operative assessment of cochlear implant candidates

    International Nuclear Information System (INIS)

    Akiba, Hidenari; Himi, Tetsuo; Hareyama, Masato

    2002-01-01

    High-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) have recently become standard pre-operative examinations for cochlear implant candidates. HRCT can demonstrate ossification and narrowing of the cochlea, but subtle calcification or soft tissue obstruction may not be detected by this method alone, and so conventional T2 weighted image (T2WI) on MRI has been recommended to disclose them. In this study, segmental analyses of the cochlea were made on three-dimensional MRI (3DMRI) and HRCT in order to predict cochlear implant difficulties. The study involved 59 consecutive patients with bilateral profound sensorineural hearing loss who underwent MRI and HRCT from November 1992 to February 1998. Etiologies of deafness were meningogenic labyrinthitis (n=9), tympanogenic labyrinthitis (n=12), and others (n=38). Pulse sequence of heavy T2WI was steady state free precession and 3DMRI was reconstructed by maximum intensity projection method. HRCT was reconstructed by bone algorithm focusing on the temporal bone. For alternative segmental analysis, cochleas were anatomically divided into five parts and each of them was classified by three ranks of score depending on 3DMRI or HRCT findings. There was a close correlation by ranks between the total score of the five parts on 3DMRI and HRCT (rs=0.86, P<0.001), and a statistically significant difference was identified between causes of deafness in the total score on 3DMRI or HRCT (P<0.001, respectively). There was a significant difference in the score among the five parts on each examination (P<0.001, respectively), and abnormal findings were more frequent in the inferior horizontal part (IHP) of the basal turn. Of the 35 patients who underwent cochlear implantation, no one had ossification in the IHP on HRCT and only one patient had an obstacle to implantation. When no signal void in the IHP on 3DMRI and no ossification in the IHP on HRCT were assumed to be the criteria for candidacy for cochlear

  10. Three-dimensional quadratic modeling and quantitative evaluation of the diaphragm on a volumetric CT scan in patients with chronic obstructive pulmonary disease

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Yongjun [School of Electrical Engineering, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon 34138 (Korea, Republic of); Bae, Jangpyo [Interdisciplinary Program, Bioengineering Major, Graduate School, Seoul National University, Seoul 08826 (Korea, Republic of); Kim, Namkug, E-mail: namkugkim@gmail.com [Department of Convergence Medicine, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul 05505 (Korea, Republic of); Park, Joo-Young; Lee, Sang Min; Seo, Joon Beom [Department of Radiology, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul 05505 (Korea, Republic of)

    2016-07-15

    Purpose: In patients with chronic obstructive pulmonary disease (COPD), diaphragm function may deteriorate due to reduced muscle fiber length. Quantitative analysis of the morphology of the diaphragm is therefore important. In the authors current study, they propose a diaphragm segmentation method for COPD patients that uses volumetric chest computed tomography (CT) data, and they provide a quantitative analysis of the diaphragmatic dimensions. Methods: Volumetric CT data were obtained from 30 COPD patients and 10 normal control patients using a 16-row multidetector CT scanner (Siemens Sensation 16) with 0.75-mm collimation. Diaphragm segmentation using 3D ray projections on the lower surface of the lungs was performed to identify the draft diaphragmatic lung surface, which was modeled using quadratic 3D surface fitting and robust regression in order to minimize the effects of segmentation error and parameterize diaphragm morphology. This result was visually evaluated by an expert thoracic radiologist. To take into consideration the shape features of the diaphragm, several quantification parameters—including the shape index on the apex (SIA) (which was computed using gradient set to 0), principal curvatures on the apex on the fitted diaphragm surface (CA), the height between the apex and the base plane (H), the diaphragm lengths along the x-, y-, and z-axes (XL, YL, ZL), quadratic-fitted diaphragm lengths on the z-axis (FZL), average curvature (C), and surface area (SA)—were measured using in-house software and compared with the pulmonary function test (PFT) results. Results: The overall accuracy of the combined segmentation method was 97.22% ± 4.44% while the visual accuracy of the models for the segmented diaphragms was 95.28% ± 2.52% (mean ± SD). The quantitative parameters, including SIA, CA, H, XL, YL, ZL, FZL, C, and SA were 0.85 ± 0.05 (mm{sup −1}), 0.01 ± 0.00 (mm{sup −1}), 17.93 ± 10.78 (mm), 129.80 ± 11.66 (mm), 163.19 ± 13.45 (mm), 71

  11. Three dimensional energy profile:

    International Nuclear Information System (INIS)

    Kowsari, Reza; Zerriffi, Hisham

    2011-01-01

    The provision of adequate, reliable, and affordable energy has been considered as a cornerstone of development. More than one-third of the world's population has a very limited access to modern energy services and suffers from its various negative consequences. Researchers have been exploring various dimensions of household energy use in order to design strategies to provide secure access to modern energy services. However, despite more than three decades of effort, our understanding of household energy use patterns is very limited, particularly in the context of rural regions of the developing world. Through this paper, the past and the current trends in the field of energy analysis are investigated. The literature on rural energy and energy transition in developing world has been explored and the factors affecting households' decisions on energy use are listed. The and the factors affecting households' decisions on energy use are listed. The gaps identified in the literature on rural household energy analysis provide a basis for developing an alternative model that can create a more realistic view of household energy use. The three dimensional energy profile is presented as a new conceptual model for assessment of household energy use. This framework acts as a basis for building new theoretical and empirical models of rural household energy use. - Highlights: ► Reviews literature on household energy, energy transitions and decision-making in developing countries. ► Identifies gaps in rural household energy analysis and develops a new conceptual framework. ► The 3-d energy profile provides a holistic view of household energy system characteristics. ► Illustrates the use of the framework for understanding household energy transitions.

  12. Three-dimensional echocardiography

    International Nuclear Information System (INIS)

    Buck, Thomas

    2011-01-01

    Presents tips and tricks for beginners and experts Provides educational material for 3D training courses Features comprehensively illustrated cases Includes an accompanying DVD with video clips of all sample cases Three-dimensional echocardiography is the most recent fundamental advancement in echocardiography. Since real-time 3D echocardiography became commercially available in 2002, it has rapidly been accepted in echo labs worldwide. This book covers all clinically relevant aspects of this fascinating new technology, including a comprehensive explanation of its basic principles, practical aspects of clinical application, and detailed descriptions of specific uses in the broad spectrum of clinically important heart disease. The book was written by a group of well-recognized international experts in the field, who have not only been involved in the scientific and clinical evolution of 3D echocardiography since its inception but are also intensively involved in expert training courses. As a result, the clear focus of this book is on the practical application of 3D echocardiography in daily clinical routine with tips and tricks for both beginners and experts, accompanied by more than 150 case examples comprehensively illustrated in more than 800 images and more than 500 videos provided on a DVD. In addition to an in-depth review of the most recent literature on real-time 3D echocardiography, this book represents an invaluable reference work for beginners and expert users of 3D echocardiography. - Tips and tricks for beginners and experts - Educational material for 3D training courses - Comprehensively illustrated cases - DVD with video clips of all sample cases.

  13. Inertial effects in three-dimensional spinodal decomposition of a symmetric binary fluid mixture: a lattice Boltzmann study

    Science.gov (United States)

    Kendon, Vivien M.; Cates, Michael E.; Pagonabarraga, Ignacio; Desplat, J.-C.; Bladon, Peter

    2001-08-01

    The late-stage demixing following spinodal decomposition of a three-dimensional symmetric binary fluid mixture is studied numerically, using a thermodynamically consistent lattice Boltzmann method. We combine results from simulations with different numerical parameters to obtain an unprecedented range of length and time scales when expressed in reduced physical units. (These are the length and time units derived from fluid density, viscosity, and interfacial tension.) Using eight large (2563) runs, the resulting composite graph of reduced domain size l against reduced time t covers 1 [less, similar] l [less, similar] 105, 10 [less, similar] t [less, similar] 108. Our data are consistent with the dynamical scaling hypothesis that l(t) is a universal scaling curve. We give the first detailed statistical analysis of fluid motion, rather than just domain evolution, in simulations of this kind, and introduce scaling plots for several quantities derived from the fluid velocity and velocity gradient fields. Using the conventional definition of Reynolds number for this problem, Re[phi] = ldl/dt, we attain values approaching 350. At Re[phi] [greater, similar] 100 (which requires t [greater, similar] 106) we find clear evidence of Furukawa's inertial scaling (l [similar] t2/3), although the crossover from the viscous regime (l [similar] t) is both broad and late (102 [less, similar] t [less, similar] 106). Though it cannot be ruled out, we find no indication that Re[phi] is self-limiting (l [similar] t1/2) at late times, as recently proposed by Grant & Elder. Detailed study of the velocity fields confirms that, for our most inertial runs, the RMS ratio of nonlinear to viscous terms in the Navier Stokes equation, R2, is of order 10, with the fluid mixture showing incipient turbulent characteristics. However, we cannot go far enough into the inertial regime to obtain a clear length separation of domain size, Taylor microscale, and Kolmogorov scale, as would be needed to test a

  14. Software applications to three-dimensional visualization of forest landscapes -- A case study demontrating the use of visual nature studio (VNS) in visualizing fire spread in forest landscapes

    Science.gov (United States)

    Brian J. Williams; Bo Song; Chou Chiao-Ying; Thomas M. Williams; John Hom

    2010-01-01

    Three-dimensional (3D) visualization is a useful tool that depicts virtual forest landscapes on computer. Previous studies in visualization have required high end computer hardware and specialized technical skills. A virtual forest landscape can be used to show different effects of disturbances and management scenarios on a computer, which allows observation of forest...

  15. The organotypic multicellular spheroid is a relevant three-dimensional model to study adenovirus replication and penetration in human tumors in vitro

    NARCIS (Netherlands)

    Grill, Jacques; Lamfers, Martine L. M.; van Beusechem, Victor W.; Dirven, Clemens M.; Pherai, D. Shareen; Kater, Mathijs; van der Valk, Paul; Vogels, Ronald; Vandertop, W. Peter; Pinedo, Herbert M.; Curiel, David T.; Gerritsen, Winald R.

    2002-01-01

    The use of adenoviruses for gene transfer and as oncolytic agents is currently receiving widespread attention. As specific constraints to adenovirus distribution and spread cannot be studied in cell cultures, there is a need for an in vitro three-dimensional (3D) model mimicking the in vivo biology

  16. A three-dimensional in vitro HepG2 cells liver spheroid model for genotoxicity studies.

    Science.gov (United States)

    Shah, Ume-Kulsoom; Mallia, Jefferson de Oliveira; Singh, Neenu; Chapman, Katherine E; Doak, Shareen H; Jenkins, Gareth J S

    2018-01-01

    The liver's role in metabolism of chemicals makes it an appropriate tissue for toxicity testing. Current testing protocols, such as animal testing and two-dimensional liver cell systems, offer limited resemblance to in vivo liver cell behaviour, in terms of gene expression profiles and metabolic competence; thus, they do not always accurately predict human toxicology. In vitro three-dimensional liver cell models offer an attractive alternative. This study reports on the development of a 3D liver model, using HepG2 cells, by a hanging-drop technique, with a focus on evaluating spheroid growth characteristics and suitability for genotoxicity testing. The cytokinesis-blocked micronucleus assay protocol was adapted to enable micronucleus (MN) detection in the 3D spheroid models. This involved evaluating the difference between hanging vs non-hanging drop positions for dosing of the test agents and comparison of automated Metafer scoring with manual scoring for MN detection in HepG2 spheroids. The initial seeding density, used for all experiments, was 5000 cells/20 μl drop hanging spheroids, harvested on day 4, with >75% cell viability. Albumin secretion (7.8 g/l) and both CYP1A1 and CYP1A2 gene expression were highest in the 3D environment at day 4. Exposure to metabolically activated genotoxicants for 24 h resulted in a 6-fold increase in CYP1A1 enzyme activity (3 μM B[a]P) and a 30-fold increase in CYP1A2 enzyme activity (5 μM PhIP) in 3D hanging spheroids. MN inductions in response to B[a]P or PhIP were 2-fold and 3-fold, respectively, and were greater in 3D hanging spheroids than in 2D format, showing that hanging spheroids are more sensitive to genotoxic agents. HepG2 hanging-drop spheroids are an exciting new alternative system for genotoxicity studies, due to their improved structural and physiological properties, relative to 2D cultures. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Three-Dimensional Modelling of a KBS-3 Canister for Spent Nuclear Fuel - some migration studies - phase II

    International Nuclear Information System (INIS)

    Pereira, Antonio

    2007-08-01

    The resistance approach is nowadays very common in compartment modelling of radionuclide mass transport. In this work we examine with the help of a finite element code a particular application of the resistance approach method as used in modelling the near field of a KBS-3V repository. The motivation behind this work is that, although conceptually simple, the resistance approach to mass transfer, using many compartments linked together by resistances, rises two important issues related to the review process: transparency and quality assurance. Transforming the real geometry of the repository system in a number of 'equivalent compartments' makes for instance the input data used by the software difficult to grasp and the codes hard to read. With our three-dimensional finite element model we simulate the release of radionuclides from a copper canister perforated by a small pinhole through which the radionuclides escape from the canister gap and migrate in the bentonite by means of diffusion until they reach the fractured rock. Release rates are calculated for two radionuclides and the breakthrough curves are compared with SKB results. This direct approach to study the impact of the resistance methodology shows that the results obtained by the 3D-model are relatively close to the predictions of the compartment models of SKB. However, our model has a pinhole with constant cross section, introducing an important conceptual difference between the two models. In the SKB-model that cross section increases suddenly at 20 000 years. This implies that the boundary conditions of the two models are different, which impacts on the breakthrough curves of radionuclides which are not short-lived, even if we only model up to 20 000 years. Therefore the agreement between the two models is better for short-lived radionuclides. It is also shown in this report that the use of a commercial package of finite elements allows build a coupled flow-and mass transport model in 3D, using

  18. The role of the circle of Willis in internal carotid artery stenosis and anatomical variations: a computational study based on a patient-specific three-dimensional model.

    Science.gov (United States)

    Zhu, Guangyu; Yuan, Qi; Yang, Jian; Yeo, Joon Hock

    2015-11-25

    The aim of this study is to provide better insights into the cerebral perfusion patterns and collateral mechanism of the circle of Willis (CoW) under anatomical and pathological variations. In the current study, a patient-specific three-dimensional computational model of the CoW was reconstructed based on the computed tomography (CT) images. The Carreau model was applied to simulate the non-Newtonian property of blood. Flow distributions in five common anatomical variations coexisting with different degrees of stenosis in the right internal carotid artery (RICA) were investigated to obtain detailed flow information. With the development of stenosis in unilateral internal carotid artery (ICA), the cerebral blood supply decreased when the degree of stenosis increased. The blood supply of the ipsilateral middle cerebral artery (MCA) was most affected by the stenosis of ICA. The anterior communicating artery (ACoA) and ipsilateral posterior communicating artery (PCoA) functioned as the important collateral circulation channels when unilateral stenosis occurred. The blood flow of the anterior circulation and the total cerebral blood flow (CBF) reached to the minimum in the configuration of the contralateral proximal anterior cerebral artery (A1) absence coexisting with unilateral ICA stenosis. Communicating arteries provided important collateral channels in the complete CoW when stenosis in unilateral ICA occurred. The cross-flow in the ACoA is a sensitive indicator of the morphological change of the ICA. The collateral function of the PCoA on the affected side will not be fully activated until a severe stenosis occurred in unilateral ICA. The absence of unilateral A1 coexisting with the stenosis in the contralateral ICA could be the most dangerous configuration in terms of the total cerebral blood supply. The findings of this study would enhance the understanding of the collateral mechanism of the CoW under different anatomical variations.

  19. [Initial study of transthoracic echocardiography guided three-dimensional printing on the application of assessment of structural heart disease].

    Science.gov (United States)

    Zhu, Y B; Liu, J S; Wang, L Q; Guan, X; Luo, Y J; Geng, J; Geng, Q G; Lin, Y J; Zhang, L X; Li, X X; Lu, Y P

    2017-08-01

    Objective: To investigate the feasibility and diagnostic value of preoperative transthoracic echocardiography guided three dimensional printing model (TTE Guided 3DPM) on the assessment of structural heart disease (SHD). Methods: From February 2016 to October 2016, 44 patients underwent cardiac surgery in Tianjin Chest Hospital, forty-four patients were assessed preoperatively using TTE Guided 3DPM, including 25 males and 19 females, aged 3-75 years, with an average of (44±22) years. compared to conventional three dimensional transthoracic echocardiography (3D-TTE), and took direct intraoperative findings as "Golden Standard" simultaneously. There are twelve patients with SHD, including four cases with mitral prolapse, two cases with partial endocardial cushion defect, two cases with secondary atrial septal defect, two cases with rheumatic mitral stenosis, one case with tetralogy of Fallot, one case with ventricular septal defect (VSD), thirty-two patients without SHD were designed as negative control. Results: The sensitivity and specificity of TTE Guided 3DPM were greater than or equal to 3D-TTE, P value of McNemar test of 3D-TTE was greater than 0.05, the difference was not statistically significant, kappa =0.745, P Guided 3DPM was greater than 0.05, the difference was not statistically significant, kappa =0.955, P Guided 3DPM and gold standards were consistent. Compared with 3D-TTE and TTE Guided 3DPM, P value was greater than 0.05, the difference was not statistically significant, kappa =0.879, P Guided 3DPM were consistent. TTE Guided 3DPM displayed the three-dimensional structure of SHD cardiac lesions clearly, which were consistent with intraoperative findings. Conclusion: TTE Guided 3DPM provides essential information for the preoperative evaluation and decision of SHD.

  20. The correlation between the paired inspiratory and expiratory three-dimensional quantitative CT and pulmonary function test in chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Sui Xi; Song Wei; Xue Huadan; Song Lan; Yang Liang; Jin Zhengyu

    2013-01-01

    Objective: To investigate the correlation between the paired inspiratory and expiratory quantitative CT and pulmonary function tests (PFTs) in patients with chronic obstructive pulmonary disease (COPD). Methods: A total of 84 patients with COPD were enrolled. For each patient, CT scan was performed in deep inspiration and expiration. Using automatic post-processing software, a three-dimension quantitative measurement was employed to assess the CT parameters of emphysema and air trapping. The correlation between CT and PFT was evaluated by the Spearman rank correlation test and multivariate linear regression analysis. Results: The percent 1 [Perc_1, (-984.28 ± 17.93) HU] and percent 15 [Perc_1_5, (-948.35 ± 22.26) HU] from the CT parameters of emphysema were positively correlated with the forced expiratory volume in 1 second predicted (FEV_1%, 48.69 ± 23, 47), the ratio of forced expiratory volume in 1 second over forced vital capacity [FEV_1/FVC, (45.89 ± 15.36)%, r = 0.45-0.67, P < 0.01], was negatively correlated with the ratio of residual volume to total lung capacity [RV/TLC, (61.32 ± 14.48)%]. The other CT parameters of emphysema index (EI) and the parameters of air trapping, the change in relative lung volume with attenuation values from -860 to -950 HU [RVC_-_8_6_0_-_-_9_5_0, (17.66 ± 22.36)%], the expiration to inspiration ratio of mean lung density (MLD_e_x_/_i_n, 0.93 ± 0.06), the expiration to inspiration ratio of lung volume (LV_e_x_/_i_n, 0.71 ± 0.14) had negative correlations with logFEV_1%, FEV_1/FVC (r = -0.48--0.69, P < 0.01) and positive correlations with RV/TLC (r = 0.41-0.66, P < 0.01). The further univariate linear regressions showed that EI, Perc_1, Pere_1_5, RVC_-_8_6_0_-_-_9_5_0, MLD_e_x_/_i_n, LV_e_x_/_i_n were correlated with the parameters of PFTs (R square values of the regression equation, ranged from 0.2