WorldWideScience

Sample records for thickness filtered quality

  1. Thickness filters for gradient based multi-material and thickness optimization of laminated composite structures

    DEFF Research Database (Denmark)

    Sørensen, Rene; Lund, Erik

    2015-01-01

    This paper presents a new gradient based method for performing discrete material and thickness optimization of laminated composite structures. The novelty in the new method lies in the application of so-called casting constraints, or thickness filters in this context, to control the thickness...... variation throughout the laminate. The filters replace the layerwise density variables with a single continuous through-the-thickness design variable. Consequently, the filters eliminate the need for having explicit constraints for preventing intermediate void through the thickness of the laminate....... Therefore, the filters reduce both the number of constraints and design variables in the optimization problem. Based upon a continuous approximation of a unit step function, the thickness filters are capable of projecting discrete 0/1 values to the underlying layerwise or ”physical” density variables which...

  2. Filter and slice thickness selection in SPECT image reconstruction

    International Nuclear Information System (INIS)

    Ivanovic, M.; Weber, D.A.; Wilson, G.A.; O'Mara, R.E.

    1985-01-01

    The choice of filter and slice thickness in SPECT image reconstruction as function of activity and linear and angular sampling were investigated in phantom and patient imaging studies. Reconstructed transverse and longitudinal spatial resolution of the system were measured using a line source in a water filled phantom. Phantom studies included measurements of the Data Spectrum phantom; clinical studies included tomographic procedures in 40 patients undergoing imaging of the temporomandibular joint. Slices of the phantom and patient images were evaluated for spatial of the phantom and patient images were evaluated for spatial resolution, noise, and image quality. Major findings include; spatial resolution and image quality improve with increasing linear sampling frequencies over the range of 4-8 mm/p in the phantom images, best spatial resolution and image quality in clinical images were observed at a linear sampling frequency of 6mm/p, Shepp and Logan filter gives the best spatial resolution for phantom studies at the lowest linear sampling frequency; smoothed Shepp and Logan filter provides best quality images without loss of resolution at higher frequencies and, spatial resolution and image quality improve with increased angular sampling frequency in the phantom at 40 c/p but appear to be independent of angular sampling frequency at 400 c/p

  3. Development of a noise filter for radiation thickness gagemeter

    International Nuclear Information System (INIS)

    Jee, C. W.; Kim, Y. T.; Lee, H. H.

    1995-01-01

    The objective of this study is to develop a filter which attenuates sensor noises of radiation thickness gagemeters of the fifth stand of TCM No. 1 in Pohang steel works. The thickness control loop for the fifth stand is modelled as a system for filter design, where the system input is the speed control input and the system output is the gagemeter output. In the design of a filter, the system is described by an ARMAX(AutoRegressive Moving-Average with auXiliary input) model. The parameters of this model are then estimated by using a recursive least square method. Secondly, the ARMAX model, the estimated system, is transformed into an observer canonical state space form. Thirdly, Kalman filtering is applied to obtain optimal estimates of the state and hence those of thickness measurements of steel strips. In addition, a separate low pass filter is designed, which is directly applicable to the gagemeter outputs. Finally, the designed filter algorithms are implemented and tested on a VMEbus board computer under VxWorks real-time operating system. (author)

  4. Influence of different anode/filter combination on radiation dose and image quality in digital mammography

    International Nuclear Information System (INIS)

    Liu Jie; Liu Peifang; Zhang Lianlian; Ma Wenjuan

    2013-01-01

    Objective: To explore the effect of different anode/filter combination on radiation dose and image quality in digital mammography, so as to choose optimal anode/filter combination to reduce radiation injury without scarifying image quality. Methods: Mammography accredition phantoms with the thickness from 1.6 cm to 8.6 cm were used to simulate human breast tissue. The same exposure conditions, pressure, compression thickness. and different anode/filter combination were employed under the automatic and manual exposure modes. The image kV, mAs, pressure, filter, average glandular dose (ACD), contrast to noise ratio (CNR) were recorded and the figure of merit (FOM) was calculated. SPSS 17.0 and one-way analysis of variance were used in the statistical analysis. Results: As the phantom thickness increase, the ACD values which were acquired with Mo/Mo, Mo/Rh, and W/Ag three different anode/filter combinations were increased, but CNR and FOM values were decreased, ACD, CNR, and FOM values which were acquired in the phantom with different thickness, and three different anode/filter combinations were statistically different (P=0.000, respectively). The ACD values of Mo/Mo were lowest. For 1.6 cm-2.6 cm phantom thicknesses, the FOMs of Mo/Rh were lowest, and for 3.6 cm-8.6 cm phantom thicknesses, the FOMs of W/Ag were lowest. Conclusion: Phantom thickness in 1.6 cm-2.6 cm and 3.6 cm-8.6 cm. Mo/Rh combination and W/Ag combination respectively can achieve the highest FOM, and can provide the best imaging quality with low radiation dose. (authors)

  5. Investigation of cooling methods and thickness considerations in the filter/window assembly for synchrotron radiation beamlines

    International Nuclear Information System (INIS)

    Wang, Z.; Kuzay, T.M.; Hahn, U.

    1993-01-01

    Synchrotron x-ray windows are vacuum separators and are usually made of thin beryllium metal. Filters are provided upstream to absorb the soft x-rays so that the window can be protected from overheating, which could result in failure. The filters are made of thin carbon products or sometimes beryllium, the same material as the window. When the synchrotron x-rays pass through a filter or window, part of the photons will be absorbed by the filter or window. The absorbed photons cause heat to build up within the filter or window. Successful filter and window designs should effectively dissipate the heat generated by the absorbed photons and guarantee the safety of the filter and window. The cooling methods typically used in a filter or window design are conduction and radiation cooling or a combination of the two. The different cooling methods were first examined with regard to efficiency and effectiveness in different temperature ranges. Analysis results are presented for temperature distribution and corresponding thermal stresses in the filter and window. Another important issue to be resolved in designing a filter/window assembly is how to select the thickness of the filters and windows. This paper focuses on the criteria for choosing the thickness of a filter: whether it is better to use a few thick filters or a series of thin ones; how to determine the minimum/maximum thickness; and the difference in thickness considerations for the window versus the filter. Numerical investigations are presented

  6. Correlation study of effect of additional filter on radiation dose and image quality in digital mammography

    International Nuclear Information System (INIS)

    Liu Jie; Liu Peifang; Wang Hongbin; Zhang Shuping; Liu Xueou

    2012-01-01

    Objective: To explore the effect of different additional filters on radiation dose and image quality in digital mammography. Methods: Hologic company's Selenia digital mammography machine and the post-processing workstations and 5 M high resolution medical monitor were used in this study. Mammography phantoms with the thickness from 1.6 cm to 8.6 cm were used to simulate human breast tissue. The same exposure conditions, pressure, compression thickness, the anode were employed with the additional filters of Mo and Rh under the automatic and manual exposure mode. The image kV, mAs, pressure, filter, average glandular dose (AGD), entrance surface dose (ESD), signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and image score according to ACR criteria were recorded for the two additional filters. Paired sample t test was performed to compare the indices of Mo and Rh groups by using SPSS 17.0. Results: AGD and ESD of Rh and Mo group were both higher with the increase of the thickness of all the phantoms. AGD, ESD and their increased value of Rh filter(1.484 ± 1.041, 7.969 ± 7.633, 0.423 ± 0.190 and 3.057 ± 2.139) were lower than those of Mo filter (1.915 ± 1.301, 12.516 ± 11.632, 0.539 ±0.246 and 4.731 ± 3.294), in all the phantoms with different thickness (t values were 4.614, 3.209, 3.396 and 3.605, P<0.05). SNR, CNR, and image score of Rh and Mo group both decreased with the increase of the thickness of all the phantoms. There were no statistical difference (P>0.05). Conclusions: Compared with Mo filter, Rh filter could reduce the radiation dose, and this advantage is more obvious in the thicker phantom when the same image quality is required. (authors)

  7. Prediction of the thickness of the compensator filter in radiation therapy using computational intelligence

    International Nuclear Information System (INIS)

    Dehlaghi, Vahab; Taghipour, Mostafa; Haghparast, Abbas; Roshani, Gholam Hossein; Rezaei, Abbas; Shayesteh, Sajjad Pashootan; Adineh-Vand, Ayoub; Karimi, Gholam Reza

    2015-01-01

    In this study, artificial neural networks (ANNs) and adaptive neuro-fuzzy inference system (ANFIS) are investigated to predict the thickness of the compensator filter in radiation therapy. In the proposed models, the input parameters are field size (S), off-axis distance, and relative dose (D/D 0 ), and the output is the thickness of the compensator. The obtained results show that the proposed ANN and ANFIS models are useful, reliable, and cheap tools to predict the thickness of the compensator filter in intensity-modulated radiation therapy

  8. Prediction of the thickness of the compensator filter in radiation therapy using computational intelligence

    Energy Technology Data Exchange (ETDEWEB)

    Dehlaghi, Vahab; Taghipour, Mostafa; Haghparast, Abbas [Department of Biomedical Engineering, Kermanshah University of Medical Sciences, Kermanshah (Iran, Islamic Republic of); Roshani, Gholam Hossein [School of Energy, Kermanshah University of Technology, Kermanshah (Iran, Islamic Republic of); Rezaei, Abbas [Department of Electrical Engineering, Kermanshah University of Technology, Kermanshah (Iran, Islamic Republic of); Shayesteh, Sajjad Pashootan [Department of Biomedical Engineering, Kermanshah University of Medical Sciences, Kermanshah (Iran, Islamic Republic of); Adineh-Vand, Ayoub [Department of Computer Engineering, Islamic Azad University, Kermanshah (Iran, Islamic Republic of); Department of Electrical Engineering, Razi University, Kermanshah (Iran, Islamic Republic of); Karimi, Gholam Reza, E-mail: ghkarimi@razi.ac.ir [Department of Electrical Engineering, Razi University, Kermanshah (Iran, Islamic Republic of)

    2015-04-01

    In this study, artificial neural networks (ANNs) and adaptive neuro-fuzzy inference system (ANFIS) are investigated to predict the thickness of the compensator filter in radiation therapy. In the proposed models, the input parameters are field size (S), off-axis distance, and relative dose (D/D{sub 0}), and the output is the thickness of the compensator. The obtained results show that the proposed ANN and ANFIS models are useful, reliable, and cheap tools to predict the thickness of the compensator filter in intensity-modulated radiation therapy.

  9. A comparison of a niobium filter (NIOBI-X) with conventional filters in x-ray radiography

    International Nuclear Information System (INIS)

    Sandborg, M.; Alm Carlsson, G.

    1990-01-01

    A 0.05 mm thick x-ray filter of niobium (NIOBI-X) has been tested and the x-ray image quality and radiation doses have been compared with conventionel x-ray filters of copper and aluminium. The results show that for x-ray tube voltage higher than 50 kV or objects thicker than 50 mm a 0.05 mm thick niobium with benefit can be replaced by a 0.11 mm thick copper filter. (25 refs.) (K.A.E.)

  10. The critical role of the barrier thickness in spin filter tunneling

    International Nuclear Information System (INIS)

    Miller, Casey W.

    2009-01-01

    Spin filter tunneling is considered in the low bias limit as functions of the temperature dependent barrier parameters. We demonstrate the generation of spin polarized tunneling currents in relation to the magnetic order parameter, and discuss how an interfacially suppressed order parameter leads to a temperature dependent tunneling current asymmetry. Analyzing the full parameter space reveals that the often overlooked barrier thickness plays a critical role in spin filter tunneling. With all else fixed, thicker barriers yield higher spin polarization, and allow a given polarization to be achieved at higher temperatures. This insight may open the door for new materials to serve as spin filter barriers.

  11. Relationship of Compressed Breast Thickness and Average Glandular Dose According to Focus/Filter

    International Nuclear Information System (INIS)

    Lee, In Ja

    2009-01-01

    The study examined the relationship between the compressed breast thickness and Average Glandular Dose (AGD) among 1,969 outpatients who went through breast X-ray in a university hospital for 10 months from July 1st, 2007 to April 30th, 2008. Then it analyzed the result acquired from 3,900 cases of Cranio-Caudal (CC) view, especially, when the breasts were compressed (13-15daN). The following is the conclusion driven from the relationship analysis. 1. The subjects aged in 40s and 50s were 2,679 out of 3,900 cases and this figure was 68.69% in all. 2. In terms of distribution depending on focus/filter, 41.0% was Mo/Mo, 34.8% was Mo/Rh, and 24.2% was Rh/Rh. 3. In terms of compressed breast thickness depending on focus/filter, the average thickness was 26.91 mm at Mo/Mo, 38.84 mm at Mo/Rh, and 48.80 mm at Rh/Rh. The average thickness of the entire cases was shown to be 36.27 mm. 4. AGD depending on focus/filter was 1.27 mGy at Mo/Mo, 1.55 mGy at Mo/Rh, and 1.42 mGy at Rh/Rh. The average glandular dose of the entire cases was shown to be 1.43 mGy. 5. The relationship of AGD depending on compressed breast thickness at Mo/Mo was y=0.0318x + 0.470 while it was y=0.0206x + 0.709 at Mo/Rh and y=0.0248x + 0.335 at Mo/Rh. It was highly influenced by the compressed breast thickness, however, more variation was detected at Mo/Mo depending on breast thickness.

  12. Wet/dry film thickness measurement of paint by absorption spectroscopy with acousto-optic tunable filter spectrometer

    Science.gov (United States)

    Sinha, Pranay G.; Xiong, Xiangchun; Jin, Feng; Trivedi, Sudhir; Prasad, Narashima S.

    2005-08-01

    Controlling/monitoring the thickness of applied paint in real time is important to many situations including painting ship and submarine hulls in dry docks for maintaining health of ships and submarines against the harshness of the sea, in automobile and aerospace industries, and in a variety of other industries as a control sensor that plays significant role in product quality, process control, and cost control. Insufficient thickness results to inadequate protection while overspray leads to waste and pollution of the environment. A rugged instrumentation for the real time non-contact accurate measurement of wet and dry paint film thickness measurement will be immensely valuable. As paint is applied with several layers of the same or different type, thickness of each newly sprayed wet layer is of most interest, but measurement on dry paint is also useful. In this study, we use acousto-optic tunable filter-based near infrared spectrometer to obtain the absorption spectrum of layers of paint sprayed on sand blasted steel surface and thus measure the thickness of coating under both wet and dry situations. NIR spectra are obtained from 1100 to 2300 nm on four sample of different thickness of paint up to 127 micron. Partial least squares model built with the spectra shows good correlation with standard error of prediction within ~ 0.7 micron. Results indicate that the spectra also respond to the amount of organic solvent in the wet paint and can be used to monitor the degree of dryness of the paint in real time.

  13. Energy trapping of thickness-extensional modes in thin film bulk acoustic wave filters

    Directory of Open Access Journals (Sweden)

    Zinan Zhao

    2016-01-01

    Full Text Available This paper presents the thickness-extensional vibration of a rectangular piezoelectric thin film bulk acoustic wave filter with two pairs of electrodes symmetrically deposited on the center of the zinc oxide film. The two-dimensional scalar differential equations which were first derived to describe in-plane vibration distribution by Tiersten and Stevens are employed. The Ritz method with trigonometric functions as basis functions is used based on a variational formulation developed in our previous paper. Free vibration resonant frequencies and corresponding modes are obtained. The modes may separate into symmetric and antisymmetric ones for such a structurally symmetric filter. Trapped modes with vibrations mainly under the driving electrodes are exhibited. The six corner-type regions of the filter neglected by Tiersten and Stevens for an approximation are taken into account in our analysis. Results show that their approximation can lead to an inaccuracy on the order of dozens of ppm for the fundamental mode, which is quite significant in filter operation and application.

  14. DOE standard: Quality assurance inspection and testing of HEPA filters

    International Nuclear Information System (INIS)

    1999-02-01

    This standard establishes essential elements for the quality assurance inspection and testing of HEPA filters by US Department of Energy (DOE)-accepted Filter Test Facilities (FTF). The standard specifies HEPA filter quality assurance inspection and testing practices established in DOE-STD-3022-98, DOE HEPA Filter Test Program, and provides a basis for the preparation of written operating procedures for primary FTF functions

  15. Inverse Problem of Air Filtration of Nanoparticles: Optimal Quality Factors of Fibrous Filters

    Directory of Open Access Journals (Sweden)

    Dahua Shou

    2015-01-01

    Full Text Available Application of nanofibers has become an emerging approach to enhance filtration efficiency, but questions arise about the decrease in Quality factor (QF for certain particles due to the rapidly increasing pressure drop. In this paper, we theoretically investigate the QF of dual-layer filters for filtration of monodisperse and polydisperse nanoparticles. The inverse problem of air filtration, as defined in this work, consists in determining the optimal construction of the two-layer fibrous filter with the maximum QF. In comparison to a single-layer substrate, improved QF values for dual-layer filters are found when a second layer with proper structural parameters is added. The influences of solidity, fiber diameter, filter thickness, face velocity, and particle size on the optimization of QF are studied. The maximum QF values for realistic polydisperse particles with a lognormal size distribution are also found. Furthermore, we propose a modified QF (MQF accounting for the effects of energy cost and flow velocity, which are significant in certain operations. The optimal MQF of the dual-layer filter is found to be over twice that of the first layer. This work provides a quick tool for designing and optimizing fibrous structures with better performance for the air filtration of specific nanoparticles.

  16. Formulation of nano-ceramic filters used in separation of heavy metals . Part II: Zirconia ceramic filters

    International Nuclear Information System (INIS)

    Khalil, T.; Labib, Sh.; Abou EI-Nour, F.H.; Abdel-Kbalik, M.

    2007-01-01

    Zirconia ceramic filters are prepared using polymeric sol-gel process. An optimization of synthesis parameters was studied to give cracked free coated nano porous film with high performance quality. Zirconia ceramic filters are characterized to select tbe optimized conditions that give tbe suitable zirconia filter used in heavy metal separation. The ceramic filters were characterized using BET method for surface measurements, mercury porosimeter for pore size distribution analysis and coating thickness measurements, SEM for microstructural studies and atomic absorption spectrophotometer (AAS) for metal analysis. The results indicated that zirconia ceramic filters. show high separation performance for cadmium, cupper, iron, manganese and lead

  17. Image Quality Enhancement Using the Direction and Thickness of Vein Lines for Finger-Vein Recognition

    Directory of Open Access Journals (Sweden)

    Young Ho Park

    2012-10-01

    Full Text Available On the basis of the increased emphasis placed on the protection of privacy, biometric recognition systems using physical or behavioural characteristics such as fingerprints, facial characteristics, iris and finger-vein patterns or the voice have been introduced in applications including door access control, personal certification, Internet banking and ATM machines. Among these, finger-vein recognition is advantageous in that it involves the use of inexpensive and small devices that are difficult to counterfeit. In general, finger-vein recognition systems capture images by using near infrared (NIR illumination in conjunction with a camera. However, such systems can face operational difficulties, since the scattering of light from the skin can make capturing a clear image difficult. To solve this problem, we proposed new image quality enhancement method that measures the direction and thickness of vein lines. This effort represents novel research in four respects. First, since vein lines are detected in input images based on eight directional profiles of a grey image instead of binarized images, the detection error owing to the non-uniform illumination of the finger area can be reduced. Second, our method adaptively determines a Gabor filter for the optimal direction and width on the basis of the estimated direction and thickness of a detected vein line. Third, by applying this optimized Gabor filter, a clear vein image can be obtained. Finally, the further processing of the morphological operation is applied in the Gabor filtered image and the resulting image is combined with the original one, through which finger-vein image of a higher quality is obtained. Experimental results from application of our proposed image enhancement method show that the equal error rate (EER of finger-vein recognition decreases to approximately 0.4% in the case of a local binary pattern-based recognition and to approximately 0.3% in the case of a wavelet transform

  18. Nondestructive quality assurance of ceramic filters using noncontact dynamic characterization

    Energy Technology Data Exchange (ETDEWEB)

    Yue, P.; Chen, S.E.; Nishihama, Y. [University of Alabama, Birmingham, AL (United States). Dept. of Civil & Environmental Engineering

    2005-06-01

    Ceramic candle filters are stiff cylindrical structures arranged in rosettes in a hot gas vessel. Custom-made with strong composite materials, these filters are designed to withstand heating and cooling cycles of very high temperature gradients during coal energy production processes. To ensure consistency in the manufactured filters, noncontact dynamic characterization using laser vibrometry is proposed as a factory quality control technique. To evaluate the proposed technique, a sensitivity study using both contact and noncontact vibration measurements is first conducted. The shift in natural vibration frequencies is used as a quality indicator for likely manufacturing variables. Six candle filters are tested using dynamic impact tests. Contact and noncontact results are compared with theoretical natural frequency values, which show that laser results were 'noisier' due to dropout from speckle noises. The results are used to establish the sensitivity of the technique, which indicates that dynamic characterization is a valid nondestructive testing technique for quality assurance of the ceramic filters, provided that the manufactured filters have a quality variation greater than 3.21%.

  19. Replicating the microbial community and water quality performance of full-scale slow sand filters in laboratory-scale filters.

    Science.gov (United States)

    Haig, Sarah-Jane; Quince, Christopher; Davies, Robert L; Dorea, Caetano C; Collins, Gavin

    2014-09-15

    Previous laboratory-scale studies to characterise the functional microbial ecology of slow sand filters have suffered from methodological limitations that could compromise their relevance to full-scale systems. Therefore, to ascertain if laboratory-scale slow sand filters (L-SSFs) can replicate the microbial community and water quality production of industrially operated full-scale slow sand filters (I-SSFs), eight cylindrical L-SSFs were constructed and were used to treat water from the same source as the I-SSFs. Half of the L-SSFs sand beds were composed of sterilized sand (sterile) from the industrial filters and the other half with sand taken directly from the same industrial filter (non-sterile). All filters were operated for 10 weeks, with the microbial community and water quality parameters sampled and analysed weekly. To characterize the microbial community phyla-specific qPCR assays and 454 pyrosequencing of the 16S rRNA gene were used in conjunction with an array of statistical techniques. The results demonstrate that it is possible to mimic both the water quality production and the structure of the microbial community of full-scale filters in the laboratory - at all levels of taxonomic classification except OTU - thus allowing comparison of LSSF experiments with full-scale units. Further, it was found that the sand type composing the filter bed (non-sterile or sterile), the water quality produced, the age of the filters and the depth of sand samples were all significant factors in explaining observed differences in the structure of the microbial consortia. This study is the first to the authors' knowledge that demonstrates that scaled-down slow sand filters can accurately reproduce the water quality and microbial consortia of full-scale slow sand filters. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Reflection color filters of the three primary colors with wide viewing angles using common-thickness silicon subwavelength gratings.

    Science.gov (United States)

    Kanamori, Yoshiaki; Ozaki, Toshikazu; Hane, Kazuhiro

    2014-10-20

    We fabricated reflection color filters of the three primary colors with wide viewing angles using silicon two-dimensional subwavelength gratings on the same quartz substrate. The grating periods were 400, 340, and 300 nm for red, green, and blue filters, respectively. All of the color filters had the same grating thickness of 100 nm, which enabled simple fabrication of a color filter array. Reflected colors from the red, green, and blue filters under s-polarized white-light irradiation appeared in the respective colors at incident angles from 0 to 50°. By rigorous coupled-wave analysis, the dimensions of each color filter were designed, and the calculated reflectivity was compared with the measured reflectivity.

  1. [Examination of patient dose reduction in cardiovasucular X-ray systems with a metal filter].

    Science.gov (United States)

    Yasuda, Mitsuyoshi; Kato, Kyouichi; Tanabe, Nobuaki; Sakiyama, Koushi; Uchiyama, Yushi; Suzuki, Yoshiaki; Suzuki, Hiroshi; Nakazawa, Yasuo

    2012-01-01

    In interventional X-ray for cardiology of flat panel digital detector (FPD), the phenomenon that exposure dose was suddenly increased when a subject thickness was thickened was recognized. At that time, variable metal built-in filters in FPD were all off. Therefore, we examined whether dose reduction was possible without affecting a clinical image using metal filter (filter) which we have been conventionally using for dose reduction. About 45% dose reduction was achieved when we measured an exposure dose at 30 cm of acrylic thickness in the presence of a filter. In addition, we measured signal to noise ratio/contrast to noise ratio/a resolution limit by the visual evaluation, and there was no influence by filter usage. In the clinical examination, visual evaluation of image quality of coronary angiography (40 cases) using a 5-point evaluation scale by a physician was performed. As a result, filter usage did not influence the image quality (p=NS). Therefore, reduction of sudden increase of exposure dose was achieved without influencing an image quality by adding filter to FPD.

  2. Tungsten anode tubes with K-edge filters for mammography

    Energy Technology Data Exchange (ETDEWEB)

    Beaman, S.; Lillicrap, S.C. (Wessex Regional Medical Physics Service, Bath (UK)); Price, J.L. (Jarvis Screening Centre, Guildford (UK))

    1983-10-01

    Optimum X-ray energies for mammography have previously been calculated using the maximum signal to noise ratio (SNR) per unit dose to the breast, or the minimum exposure for constant SNR. Filters having absorption edges at appropriate energy positions have been used to modify the shape of tungsten anode spectra towards the calculated optimum. The suitability of such spectra for practical use has been assessed by comparing the film image quality and the incident breast dose obtained using a K-edge filtered tungsten anode tube with that obtained using a molybdenum anode. Image quality has been assessed by using a 'random' phantom and by comparing mammograms where one breast was radiographed using a filtered tungsten anode tube and the other using a standard molybdenum anode unit. Relative breast doses were estimated from both ionisation chamber measurements with a phantom and thermoluminescent dosimetry measurements on the breast. Film image quality assessment indicated that the filtered tungsten anode tube gave results not significantly different from those obtained with a molybdenum anode tube for a tissue thickness of about 4 cm and which were better for larger breast thicknesses. Doses could be reduced to between one-half and one-third with the filtered tungsten anode tube.

  3. Tungsten anode tubes with K-edge filters for mammography

    International Nuclear Information System (INIS)

    Beaman, S.; Lillicrap, S.C.; Price, J.L.

    1983-01-01

    Optimum X-ray energies for mammography have previously been calculated using the maximum signal to noise ratio (SNR) per unit dose to the breast, or the minimum exposure for constant SNR. Filters having absorption edges at appropriate energy positions have been used to modify the shape of tungsten anode spectra towards the calculated optimum. The suitability of such spectra for practical use has been assessed by comparing the film image quality and the incident breast dose obtained using a K-edge filtered tungsten anode tube with that obtained using a molybdenum anode. Image quality has been assessed by using a 'random' phantom and by comparing mammograms where one breast was radiographed using a filtered tungsten anode tube and the other using a standard molybdenum anode unit. Relative breast doses were estimated from both ionisation chamber measurements with a phantom and thermoluminescent dosimetry measurements on the breast. Film image quality assessment indicated that the filtered tungsten anode tube gave results not significantly different from those obtained with a molybdenum anode tube for a tissue thickness of abut 4 cm and which were better for larger breast thicknesses. Doses could be reduced to between one-half and one-third with the filtered tungsten anode tube. (U.K.)

  4. Oriented diffusion filtering for enhancing low-quality fingerprint images

    KAUST Repository

    Gottschlich, C.; Schönlieb, C.-B.

    2012-01-01

    To enhance low-quality fingerprint images, we present a novel method that first estimates the local orientation of the fingerprint ridge and valley flow and next performs oriented diffusion filtering, followed by a locally adaptive contrast enhancement step. By applying the authors' new approach to low-quality images of the FVC2004 fingerprint databases, the authors are able to show its competitiveness with other state-of-the-art enhancement methods for fingerprints like curved Gabor filtering. A major advantage of oriented diffusion filtering over those is its computational efficiency. Combining oriented diffusion filtering with curved Gabor filters led to additional improvements and, to the best of the authors' knowledge, the lowest equal error rates achieved so far using MINDTCT and BOZORTH3 on the FVC2004 databases. The recognition performance and the computational efficiency of the method suggest to include oriented diffusion filtering as a standard image enhancement add-on module for real-time fingerprint recognition systems. In order to facilitate the reproduction of these results, an implementation of the oriented diffusion filtering for Matlab and GNU Octave is made available for download. © 2012 The Institution of Engineering and Technology.

  5. Oriented diffusion filtering for enhancing low-quality fingerprint images

    KAUST Repository

    Gottschlich, C.

    2012-01-01

    To enhance low-quality fingerprint images, we present a novel method that first estimates the local orientation of the fingerprint ridge and valley flow and next performs oriented diffusion filtering, followed by a locally adaptive contrast enhancement step. By applying the authors\\' new approach to low-quality images of the FVC2004 fingerprint databases, the authors are able to show its competitiveness with other state-of-the-art enhancement methods for fingerprints like curved Gabor filtering. A major advantage of oriented diffusion filtering over those is its computational efficiency. Combining oriented diffusion filtering with curved Gabor filters led to additional improvements and, to the best of the authors\\' knowledge, the lowest equal error rates achieved so far using MINDTCT and BOZORTH3 on the FVC2004 databases. The recognition performance and the computational efficiency of the method suggest to include oriented diffusion filtering as a standard image enhancement add-on module for real-time fingerprint recognition systems. In order to facilitate the reproduction of these results, an implementation of the oriented diffusion filtering for Matlab and GNU Octave is made available for download. © 2012 The Institution of Engineering and Technology.

  6. A Data Quality Filter for PMU Measurements: Description, Experience, and Examples

    Energy Technology Data Exchange (ETDEWEB)

    Follum, James D.; Amidan, Brett G.

    2016-07-17

    Networks of phasor measurement units (PMUs) continue to grow, and along with them, the amount of data available for analysis. With so much data, it is impractical to identify and remove poor quality data manually. The data quality filter described in this paper was developed for use with the Data Integrity and Situation Awareness Tool (DISAT), which analyzes PMU data to identify anomalous system behavior. The filter operates based only on the information included in the data files, without supervisory control and data acquisition (SCADA) data, state estimator values, or system topology information. Measurements are compared to preselected thresholds to determine if they are reliable. Along with the filter's description, examples of data quality issues from application of the filter to nine months of archived PMU data are provided. The paper is intended to aid the reader in recognizing and properly addressing data quality issues in PMU data.

  7. Improving the quality of brain CT image from Wavelet filters

    International Nuclear Information System (INIS)

    Pita Machado, Reinaldo; Perez Diaz, Marlen; Bravo Pino, Rolando

    2012-01-01

    An algorithm to reduce Poisson noise is described using Wavelet filters. Five tomographic images of patients and a head anthropomorphic phantom were used. They were acquired with two different CT machines. Due to the original images contain the acquisition noise; some simulated free noise lesions were added to the images and after that the whole images were contaminated with noise. Contaminated images were filtered with 9 Wavelet filters at different decomposition levels and thresholds. Image quality of filtered and unfiltered images was graded using the Signal to Noise ratio, Normalized Mean Square Error and the Structural Similarity Index, as well as, by the subjective JAFROC methods with 5 observers. Some filters as Bior 3.7 and dB45 improved in a significant way head CT image quality (p<0.05) producing an increment in SNR without visible structural distortions

  8. Study for evaluation of filter thickness in the determination of k Vp in function of the attenuation relative factors of the radiation

    International Nuclear Information System (INIS)

    Martin, J.G.; Souza, R.T.F.; Carbi, E.D.O.; Pina, D.R.

    2009-01-01

    This work consisted of evaluating 3 pairs of filters (cupper). The aim of it was to verify the best combination between attenuating material thicknesses for determination voltage value applied to X ray tube as function of attenuation relative factors. The employed methodology consisted of measuring the relative expositions, using thicknesses copper plates: (0,3, 0,5 and 0,8) mm. The thicknesses had been combined between itself with the purpose to form pairs of filters look that used ones ink Vp measurers. The great kVp band was used for 3 X ray equipment with generators of single-phase. Three-phase tension of 12 pulses and generator of tension in high frequency. The results had pointed the best combination, the thicknesses of filters (0,5/0,3) mm, because it does not have presented duplicity of values throughout all the band of evaluated tension. The results had still shown that the relative attenuation factors had not suffered significant variations between the different equipment with different voltage wave form. The variations found are related with differences in the effective energy of X ray beam. (author)

  9. Comparison of image quality and effective dose by additional filtration on digital chest tomosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kye Sun [Dept. of Dignostic Radiology, Samsung Medical Center, Seoul (Korea, Republic of); Kim, Sung Chul [Dept. of Radiological Science, Gachon University, Sungnam (Korea, Republic of)

    2015-12-15

    The purpose of this study is to suggest proper additional filtration by comparisons patient dose and image quality among additional filters in digital chest tomosynthesis (DTS). We measured the effective dose, dose area product (DAP) by changing thickness of Cu, Al and Ni filter to compare image quality by CD curve and SNR, CNR. Cu, Al and Ni exposure dose were similar thickness 0.3 mm, 3 mm and 0.3 mm respectively. The exposure dose using filter was decreased average about 33.1% than non filter. The DAP value of 0.3 mm Ni were decreased 72.9% compared to non filter and the lowest dose among 3 filter. The effective dose of 0.3 mm Ni were decreased 48% compared to 0.102 mSv effective dose of non filter. At the result of comparison of image quality through CD curve there were similar aspect graph among Cu, Al and Ni. SNR was decreased average 19.07%, CNR was average decreased 18.17% using 3 filters. In conclusion, Ni filtration was considered to be most suitable when considered comprehensive thickness, character, sort of filter, dose reduction and image quality evaluation in DTS.

  10. Hybrid Active-Passive Microwave Photonic Filter with High Quality Factor

    International Nuclear Information System (INIS)

    En-Ming, Xu; Xin-Liang, Zhang; Li-Na, Zhou; Yu, Zhang; De-Xiu, Huang

    2009-01-01

    A hybrid high quality factor (Q-factor) microwave photonic filter with a cascaded active filter and a passive filter is presented and experimentally demonstrated. The active infinite impulse response filter is realized by a recirculating delay line loop with a semiconductor optical amplifier, and a much narrower 3 dB bandwidth of response peaks can be achieved. A passive finite impulse response filter is realized by an unbalance Mach–Zehnder interferometer, and it is cascaded to select the desired filter frequencies and to suppress the intermediate peaks. Compared with the purely active filter scheme, the free spectrum range and the Q-factor of the hybrid structure can be doubled. Stable operation and a high Q-factor of 362 are experimentally demonstrated

  11. Aircraft Recirculation Filter for Air-Quality and Incident Assessment.

    Science.gov (United States)

    Eckels, Steven J; Jones, Byron; Mann, Garrett; Mohan, Krishnan R; Weisel, Clifford P

    The current research examines the possibility of using recirculation filters from aircraft to document the nature of air-quality incidents on aircraft. These filters are highly effective at collecting solid and liquid particulates. Identification of engine oil contaminants arriving through the bleed air system on the filter was chosen as the initial focus. A two-step study was undertaken. First, a compressor/bleed air simulator was developed to simulate an engine oil leak, and samples were analyzed with gas chromatograph-mass spectrometry. These samples provided a concrete link between tricresyl phosphates and a homologous series of synthetic pentaerythritol esters from oil and contaminants found on the sample paper. The second step was to test 184 used aircraft filters with the same gas chromatograph-mass spectrometry system; of that total, 107 were standard filters, and 77 were nonstandard. Four of the standard filters had both markers for oil, with the homologous series synthetic pentaerythritol esters being the less common marker. It was also found that 90% of the filters had some detectable level of tricresyl phosphates. Of the 77 nonstandard filters, 30 had both markers for oil, a significantly higher percent than the standard filters.

  12. Aircraft Recirculation Filter for Air-Quality and Incident Assessment

    Science.gov (United States)

    Eckels, Steven J.; Jones, Byron; Mann, Garrett; Mohan, Krishnan R.; Weisel, Clifford P.

    2015-01-01

    The current research examines the possibility of using recirculation filters from aircraft to document the nature of air-quality incidents on aircraft. These filters are highly effective at collecting solid and liquid particulates. Identification of engine oil contaminants arriving through the bleed air system on the filter was chosen as the initial focus. A two-step study was undertaken. First, a compressor/bleed air simulator was developed to simulate an engine oil leak, and samples were analyzed with gas chromatograph-mass spectrometry. These samples provided a concrete link between tricresyl phosphates and a homologous series of synthetic pentaerythritol esters from oil and contaminants found on the sample paper. The second step was to test 184 used aircraft filters with the same gas chromatograph-mass spectrometry system; of that total, 107 were standard filters, and 77 were nonstandard. Four of the standard filters had both markers for oil, with the homologous series synthetic pentaerythritol esters being the less common marker. It was also found that 90% of the filters had some detectable level of tricresyl phosphates. Of the 77 nonstandard filters, 30 had both markers for oil, a significantly higher percent than the standard filters. PMID:25641977

  13. Equivalent half-value thickness and mean energies of filtered X-ray bremsstrahlung spectra

    International Nuclear Information System (INIS)

    Seelentag, W.W.; Panzer, W.

    1980-01-01

    X-ray beam qualities are often conveniently described by half-value thicknesses (in connection with tube voltage and filtration). Aluminium and copper are commonly used as half-value thickness materials, and either material may be used in a large intermediate energy range. Data comparisons frequently require conversions from values in Al to values in Cu. Equivalent half-value thicknesses for polychromatic radiations depend on the shapes of the spectra, but spectrometry is too expensive for routine application. Half-value thicknesses in both Al and Cu have been determined for some 250 spectra (tube potentials 10 to 300 kV). The results are tabulated, and these results together with a nomogram enable conversion with an accuracy of better than +- 5% in most cases. (UK)

  14. Preliminary analysis on the water quality index (WQI) of irradiated basic filter elements

    Science.gov (United States)

    Arif Abu Bakar, Asyraf; Muhamad Pauzi, Anas; Aziz Mohamed, Abdul; Syima Sharifuddin, Syazrin; Mohamad Idris, Faridah

    2018-01-01

    Simple water filtration system is needed in times of extreme floods. Clean water for sanitation at evacuation centres is essential and its production is possible by using the famous simple filtration system consisting of empty bottle and filter elements (sands, gravels, cotton/coffee filter). This research intends to study the effects of irradiated filter elements on the filtration effectiveness through experiments. The filter elements will be irradiated with gamma and neutron radiation using the facilities available at Malaysia Nuclear Agency. The filtration effectiveness is measured using the water quality index (WQI) that is developed in this study to reflect the quality of filtered water. The WQI of the filtered water using the system with irradiated filter elements is then compared with that of the system with non-irradiated filter elements. This preliminary analysis only focus on filtration element of silica sand. Results shows very nominal variation in in WQI after filtered by non-irradiated, gamma and neutron filter element (silica sand), where the hypothesis could not be affirmed.

  15. Membrane metamaterial resonators with a sharp resonance: A comprehensive study towards practical terahertz filters and sensors

    Directory of Open Access Journals (Sweden)

    Yongyao Chen

    2012-06-01

    Full Text Available We investigate the resonant properties of high quality-factor membrane-based metamaterial resonators functioning in the terahertz regime. A number of factors, including the resonator geometry, dielectric loss, and most importantly the membrane thickness are found to extensively influence the resonance strength and quality factor of the sharp resonance. Further studies on the membrane thickness-dependent-sensitivity for sensing applications reveal that high quality-factor membrane metamaterials with a moderate thickness ranging from 10 to 50 μm are the most promising option towards developing realistic integrated terahertz filters and sensors.

  16. The effects of slice thickness and reconstructive parameters on VR image quality in multi-slice CT

    International Nuclear Information System (INIS)

    Gao Zhenlong; Wang Qiang; Liu Caixia

    2005-01-01

    Objective: To explore the effects of slice thickness, reconstructive thickness and reconstructive interval on VR image quality in multi-slice CT, in order to select the best slice thickness and reconstructive parameters for the imaging. Methods: Multi-slice CT scan was applied on a rubber dinosaur model with different slice thickness. VR images were reconstructed with different reconstructive thickness and reconstructive interval. Five radiologists were invited to evaluate the quality of the images without knowing anything about the parameters. Results: The slice thickness, reconstructive thickness and reconstructive interval did have effects on VR image quality and the effective degree was different. The effective coefficients were V 1 =1413.033, V 2 =563.733, V 3 =390.533, respectively. The parameters interacted with the others (P<0.05). The smaller of those parameters, the better of the image quality. With a small slice thickness and a reconstructive slice equal to slice thickness, the image quality had no obvious difference when the reconstructive interval was 1/2, 1/3, 1/4 of the slice thickness. Conclusion: A relative small scan slice thickness, a reconstructive slice equal to slice thickness and a reconstructive interval 1/2 of the slice thickness should be selected for the best VR image quality. The image quality depends mostly on the slice thickness. (authors)

  17. Effects of noise, nonlinear processing, and linear filtering on perceived music quality.

    Science.gov (United States)

    Arehart, Kathryn H; Kates, James M; Anderson, Melinda C

    2011-03-01

    The purpose of this study was to determine the relative impact of different forms of hearing aid signal processing on quality ratings of music. Music quality was assessed using a rating scale for three types of music: orchestral classical music, jazz instrumental, and a female vocalist. The music stimuli were subjected to a wide range of simulated hearing aid processing conditions including, (1) noise and nonlinear processing, (2) linear filtering, and (3) combinations of noise, nonlinear, and linear filtering. Quality ratings were measured in a group of 19 listeners with normal hearing and a group of 15 listeners with sensorineural hearing impairment. Quality ratings in both groups were generally comparable, were reliable across test sessions, were impacted more by noise and nonlinear signal processing than by linear filtering, and were significantly affected by the genre of music. The average quality ratings for music were reasonably well predicted by the hearing aid speech quality index (HASQI), but additional work is needed to optimize the index to the wide range of music genres and processing conditions included in this study.

  18. Improvement of the steel quality through zirconia base ceramic filter

    International Nuclear Information System (INIS)

    Santos, Benedito M.; Foschini, Cesar R.; Santos, Ieda M.G.; Pinheiro, Adriano S.; Paskocimas, Carlos A.; Leite, Edson R.; Longo, Elson

    1997-01-01

    At the end of production, the steel presents inclusions own to the making process. Ceramics filters, with controlled porosity, are being produced to eliminate the impurities, so as to increase the good quality steel production. This work studies the optimization of the zirconia filters composition and production for siderurgical processes application. The study was done through the granulometric control, using BET, XRD and Hg Porosimetry. (author)

  19. Purcell filter of unusual shape in fair superferric sextupole magnet for improving the field quality

    International Nuclear Information System (INIS)

    Sarma, P.R.; Dutta Gupta, A.; Nandi, C.; Saha, S.; Chattopadhyay, S.; Pal, G.

    2013-01-01

    In the Energy Buncher Section of the Super-FRS of the FAIR project, magnets of very high quality and wide aperture are needed. Wide aperture of these magnets generates large end-effects which can be reduced by end shaping and using Purcell filters which are voids in the pole for modifying the field. In the present work we have investigated various shapes of Purcell filters in magnets, especially in superferric sextupole magnets. Conventional Purcell filters are through and through rectangular voids in the pole region, a little away from the pole face. We have seen that the length of the Purcell filter is an important parameter which can be optimized. Thus one can use partially penetrating filters. We have further shown that Purcell filters of unusual geometry which start right from the pole face can be effectively used in reducing the weight of the iron, while keeping the field quality intact or improve the field quality, keeping the weight constant. (author)

  20. The proton induced X-ray emission (PIXE) for the quantitative analysis of elements in thin samples, in surface layers of thick samples, and in aerosol filters

    International Nuclear Information System (INIS)

    Waetjen, U.

    1983-01-01

    The PIXE analysis method for the determination of elements in thick samples was investigated. The text of the present thesis is arranged under the following headings: physical fundamentals and measuring equipment, quantitative analysis of thin samples, matrix effects at the PIXE analysis of thick samples, matrix correction methods, analysis of 'infinite thick' model substances, PIXE analysis of aerosol filters. (GSCH)

  1. Integration of Computer Tomography and Simulation Analysis in Evaluation of Quality of Ceramic-Carbon Bonded Foam Filter

    Directory of Open Access Journals (Sweden)

    Karwiński A.

    2013-12-01

    Full Text Available Filtration of liquid casting alloys is used in casting technologies for long time. The large quantity of available casting filters allows using them depending on casting technology, dimensions of casting and used alloys. Technological progress of material science allows of using new materials in production of ceramic filters. In this article the Computed Tomography (CT technique was use in order to evaluate the thickness of branch in cross section of 20ppi ceramic-carbon bonded foam filter. Than the 3D image of foam filter was used in computer simulation of flow of liquid metal thru the running system.

  2. Enhancing indoor air quality -The air filter advantage.

    Science.gov (United States)

    Vijayan, Vannan Kandi; Paramesh, Haralappa; Salvi, Sundeep Santosh; Dalal, Alpa Anil Kumar

    2015-01-01

    Air pollution has become the world's single biggest environmental health risk, linked to around 7 million deaths in 2012 according to a recent World Health Organisation (WHO) report. The new data further reveals a stronger link between, indoor and outdoor air pollution exposure and cardiovascular diseases, such as strokes and ischemic heart disease, as well as between air pollution and cancer. The role of air pollution in the development of respiratory diseases, including acute respiratory infections and chronic obstructive pulmonary diseases, is well known. While both indoor and outdoor pollution affect health, recent statistics on the impact of household indoor pollutants (HAP) is alarming. The WHO factsheet on HAP and health states that 3.8 million premature deaths annually - including stroke, ischemic heart disease, chronic obstructive pulmonary disease (COPD) and lung cancer are attributed to exposure to household air pollution. Use of air cleaners and filters are one of the suggested strategies to improve indoor air quality. This review discusses the impact of air pollutants with special focus on indoor air pollutants and the benefits of air filters in improving indoor air quality.

  3. Antecedent thermal injury worsens split-thickness skin graft quality: A clinically relevant porcine model of full-thickness burn, excision and grafting.

    Science.gov (United States)

    Carlsson, Anders H; Rose, Lloyd F; Fletcher, John L; Wu, Jesse C; Leung, Kai P; Chan, Rodney K

    2017-02-01

    Current standard of care for full-thickness burn is excision followed by autologous split-thickness skin graft placement. Skin grafts are also frequently used to cover surgical wounds not amenable to linear closure. While all grafts have potential to contract, clinical observation suggests that antecedent thermal injury worsens contraction and impairs functional and aesthetic outcomes. This study evaluates the impact of antecedent full-thickness burn on split-thickness skin graft scar outcomes and the potential mediating factors. Full-thickness contact burns (100°C, 30s) were created on the backs of anesthetized female Yorkshire Pigs. After seven days, burn eschar was tangentially excised and covered with 12/1000th inch (300μm) split-thickness skin graft. For comparison, unburned wounds were created by sharp excision to fat before graft application. From 7 to 120days post-grafting, planimetric measurements, digital imaging and biopsies for histology, immunohistochemistry and gene expression were obtained. At 120days post-grafting, the Observer Scar Assessment Scale, colorimetry, contour analysis and optical graft height assessments were performed. Twenty-nine porcine wounds were analyzed. All measured metrics of clinical skin quality were significantly worse (pskin graft quality, likely by multiple mechanisms including burn-related inflammation, microscopically inadequate excision, and dysregulation of tissue remodeling. A valid, reliable, clinically relevant model of full-thickness burn, excision and skin replacement therapy has been demonstrated. Future research to enhance quality of skin replacement therapies should be directed toward modulation of inflammation and assessments for complete excision. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.

  4. Liquid film thickness and interfacial wave propagate in venturi scrubber for filtered venting

    International Nuclear Information System (INIS)

    Nakao, Yasuhiro; Horiguchi, Naoki; Kanagawa, Tetsuya; Kaneko, Akiko; Abe, Yutaka; Yoshida, Hiroyuki

    2016-01-01

    As one of filtered venting systems which should be installed in light water reactors from the viewpoint of protecting a containment vessel and suppressing the diffusion of radioactive materials, there is a system composed of venturi scrubbers. The radioactive materials in the contaminated gas are collected into liquid. By forming dispersed flow in the venturi scrubber, interfacial area between liquid and gas is enhanced, finally, large decontamination factor is realized. In evaluation for the decontamination performance of the venturi scrubber, interface characteristics of droplets and liquid film are important. In this study, as a part of evaluation method of the interfacial area, the liquid film thickness in the venturi scrubber was measured. And evaluate the results of investigation experimentally for each ruffling average thickness and liquid film in a fluidized condition. The cross section area of a venturi scrubber is a rectangular one manufactured a transparent acrylic for visualization. In the venturi scrubber, a pressure drop occurs in the throat part by the inflow of air from the compressor. Water flows from the tank by a pressure difference between a suctioned hole with head pressure and a throat part. An annular spray flow is then formed in the venturi scrubber. (author)

  5. Bank filtered water quality characteristics in Okgog-Ri area of Youngsan-River, Korea

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hee-Youl; Kim, Hyoung-Soo [Korea Water Resources Corp., Taejeon(Korea)

    2001-02-28

    Preliminary artificial recharge groundwater intake method using bank filtering had been conducted in Okgog-Ri of Youngsan-River to evaluate the possibility of substitution of surface water intake method in the area. In order to investigate the characteristics of bank filtered groundwater, we examined the hydrogeological properties of alluvium and water quality of stream and groundwater. It is observed that nitrate in stream water from synthetic fertilizer and poultry manure is almost consumed during bank filtering in this area. This implies that denitrification of organic carbon and the oxidation of pyrite present in the alluvium aquifer. Groundwater samples from bank filtering show high Mn concentration. This high Mn concentration may be resulted from decreasing redox potential due to denitrification and increasing mobility due to redox reaction of Mn-oxide. In the study area, there is a typical tendency that Al concentrations of water samples decrease according to increasing pH. This tendency is interpreted as forming of amorphous Al(OH){sub 3} precipitates by reducing the Al{sup 3+} solubilities. It is revealed that the bank filtered groundwater in the area is not edible because color, turbidity, heterotrophic bacteria, coliform and Mn of the groundwater exceed the guideline of drinking water. Even though the bank filtered groundwater without treatment does not satisfy the guideline of drinking water, the groundwater shows a good water quality compared with stream water. So, the water treatment method using bank filtered groundwater can be more economical and efficient than the treatment using direct intake of stream water in the aspect of water quality. (author). 15 refs., 2 tabs., 7 figs.

  6. Octennial History of the Development and Quality of High-Efficiency Filters for the US Atomic Energy Program

    Energy Technology Data Exchange (ETDEWEB)

    Gilbert, H. [United States Atomic Energy Commission, Washington, DC (United States)

    1968-12-15

    Two facilities are operated for the US atomic energy commission in its program to ensure the uniform quality of commercially manufactured high-efficiency particulate filters. the filter-testing program was started in january 1960 after it was realized that the commercial fire-resistant product incorporated deficiencies of manufacture. the record of testing for quality assurance by the two facilities and an analysis of factors governing the quality of filters are presented. the analysis is complemented with a description of efforts, made in the course of the filter testing, to improve the design of the filter for efficiency and reliability. the fire-resistant (hepa) filter of 1959 was inadequate. the inadequacy of the filter, now judged by reflection, was brought about by the intensive accelerated efforts to replace and preclude, wherever possible in the US atomic energy program, use of filters made of combustible materials. this desire for fire resistance of filters has proliferated widely among other members of the international atomic energy family. the intensive AEC effort caused US industry to produce filters of fire-resistant design but without the opportunity for development of manufacturing technology adequate for ensuring reliability of the filter. the state of the fire-resistant filter today is in sharp contrast to the 1959 filter. the testing program, coupled with a program for continuing improvement of the filter, has resulted in the effective removal of radioactive aerosols at atomic energy installations on a consistent and dependable basis. (author)

  7. MO-FG-CAMPUS-IeP2-01: Characterization of Beam Shaping Filters and Photon Spectra From HVL Profiles in CT

    Energy Technology Data Exchange (ETDEWEB)

    Bujila, R [Karolinska University Hospital, Stockholm (Sweden); Royal Institute of Technology, Stockholm (Sweden); Kull, L [Sunderby Hospital, Lulea (Sweden); Nowik, P; Poludniowski, G [Karolinska University Hospital, Stockholm (Sweden); Andersson, J [Umea University, Umea (Sweden)

    2016-06-15

    Purpose: Advanced dosimetry in CT (e.g. the Monte Carlo method) requires an accurate characterization of the shaped filter and radiation quality used during a scan. The purpose of this work was to develop a method where half value layer (HVL) profiles along shaped filters could be made. From the HVL profiles the beam shaping properties and effective photon spectrum for a particular scan can be inferred. Methods: A measurement rig was developed to allow determinations of the HVL under a scatter-free narrow-beam geometry and constant focal spot to ionization chamber distance for different fan angles. For each fan angle the HVL is obtained by fitting the transmission of radiation through different thicknesses of an Al absorber (type 1100) using an appropriate model. The effective Al thickness of shaped filters and effective photon spectra are estimated using a model of photon emission from a Tungsten anode. This method is used to obtain the effective photon spectra and effective Al thickness of shaped filters for a CT scanner recently introduced to the market. Results: This study resulted in a set of effective photon spectra (central ray) for each kVp along with effective Al thicknesses of the different shaped filters. The effective photon spectra and effective Al thicknesses of shaped filters were used to obtain numerically approximated HVL profiles and compared to measured HVL profiles (mean absolute percentage error = 0.02). The central axis HVL found in the vendor’s technical documentation were compared to approximated HVL values (mean absolute percentage error = 0.03). Conclusion: This work has resulted in a unique method of measuring HVL profiles along shaped filters in CT. Further the effective photon spectra and the effective Al thicknesses of shaped filters that were obtained can be incorporated into Monte Carlo simulations.

  8. Application of the ROC method to assessment of image quality issues in mammography. Part 2. Comparative evaluation of image quality and radiation dose to thick body sections

    International Nuclear Information System (INIS)

    Klein, R.; Saebel, M.

    2000-01-01

    For the experimental comparative assessment reported, the following radiation qualities were compared for radiation dose applied and image quality: molydenum anode, 30mum molybdenum filter, X-ray tube potential differences of 26-32 kV; molybdenum anode, 25 mum rhodium filter, X-ray tube potential differences of 26-32 kV; tungsten anode, 50 mum rhodium filter, X-ray tube potential differences of 26-32 kV. The results show that in the differentiated assessment according to the various radiation qualities, significant deviations in imaging quality of the different detail types are possible. (orig./CB) [de

  9. The effectiveness of the use of filter on the tilapia growth performance, number of Nitrosomonas sp., and water quality in aquaponics systems

    Directory of Open Access Journals (Sweden)

    Yuli Andriani

    2018-01-01

    Full Text Available ABSTRACT This study aims to determine the most effective type of living filter media for the bacteria Nitrosomonas sp. in order to improve water quality in aquaponics systems. The method used in this study was completely randomized design, consisting of five treatments and each was repeated three times. The treatments were: A (without addition of filter media, B (addition of palm fibers, silica sand, and activated carbon, C (addition of palm fibers, silica sand, gravel, and activated carbon, D (addition of palm fibers, silica sand, rocks, and activated carbon, and E (addition of palm fibers, silica sand, bioball, and activated carbon. Parameters measured were: 1 the number of Nitrosomonas bacteria, 2 water quality (ammonia, nitrate, and phosphate; and, 3 productivity of fish and Chinese spinach. Data were analyzed using a descriptive method. The findings show that the highest number of bacteria was found in treatment E, 9.29×105 CFU/mL on the bioball filter media and 4.43×105 CFU/mL in rearing tanks. The best water quality was in treatment B, with a concentration of ammonia of 0.17 mg/L, nitrate of 0.33 mg/L, and phosphate of 0.54 mg/L. Plant productivity was the best in treatment B in which the average length and weight reach 48.1 cm and 11.1 grams of plant/week, respectively. The best fish growth was seen in treatment C with an absolute growth rate of 4.4 grams and a specific growth rate of 1.9%/day. The recommended filter was made of Arenga pinnata fibers, silica sand, gravels, and active carbon of about 2 cm thick each.The results showed that the type of filter on the aquaponic system had an effect on the amount of Nitrosomonas sp. in water, water quality, and the productivity of Chinese spinach.Keywords: aquaponics, filter, water quality, Nitrosomonas sp.ABSTRAKPenelitian ini bertujuan untuk menentukan jenis filter yang paling efektif sebagai media hidup bakteri Nitrosomonas sp. sehingga menghasilkan kualitas air yang baik dalam sistem

  10. Scandium/carbon filters for soft x rays

    NARCIS (Netherlands)

    Artioukov, IA; Kasyanov, YS; Kopylets, IA; Pershin, YP; Romanova, SA

    2003-01-01

    This Note deals with thin-film soft x-ray filters for operation at the wavelengths near carbon K edge (similar to4.5 nm). The filters were fabricated by magnetron sputtering deposition of thin layers of scandium (total thickness 0.1-0.2 mum) onto films of polypropylene (thickness 1.5 mum) and

  11. Bowtie filter and water calibration in the improvement of cone beam CT image quality

    International Nuclear Information System (INIS)

    Li Minghui; Dai Jianrong; Zhang Ke

    2010-01-01

    Objective: To evaluate the improvement of cone beam CT (CBCT) image quality by using bewtie filter (F 1 ) and water calibration. Methods: First the multi-level gain calibration of the detector panel with the method of Cal 2 calibration was performed, and the CT images of CATPHAN503 with F 0 and bowtie filter were collected, respectively. Then the detector panel using water calibration kit was calibrated, and images were acquired again. Finally, the change of image quality after using F 1 and (or) water calibration method was observed. The observed indexes included low contrast visibility, spatial uniformity, ring artifact, spatial resolution and geometric accuracy. Results: Comparing with the traditional combination of F 0 filter and Cal 2 calibration, the combination of bowtie filter F 1 and water calibration improves low contrast visibility by 13.71%, and spatial uniformity by 54. 42%. Water calibration removes ring artifacts effectively. However, none of them improves spatial resolution and geometric accuracy. Conclusions: The combination of F 1 and water calibration improves CBCT image quality effectively. This improvement is aid to the registration of CBCT images and localization images. (authors)

  12. Possibility of clinical usefulness of heavy metal filter combinations in digital chest radiography

    International Nuclear Information System (INIS)

    Kawaji, Yasuyuki; Ideguchi, Tadamitsu; Ikeda, Hirotaka; Sakamoto, Hiromi; Higashida, Yoshiharu; Toyofuku, Fukai

    2003-01-01

    We have investigated the potential usefulness of the heavy metal filters with higher atomic numbers by comparing their patient exposures, tube loadings, radiographic contrasts, and the visual detection of simulated nodules in computed radiography (CR) with those of a combination of copper and aluminum. Seven heavy metal filters were used for this study. As for a tungsten filter, two filters different in thickness were used. One is 0.05 mm thick, and the other 0.10 mm. The other metal filters were respectively combined with a tungsten filter with a thickness of 0.05 mm. Among the all filters, tungsten with 0.1 mm thick and tungsten with 0.05 mm+barium which showed larger advantages in patient exposure and tube loading than those of the other filters were used for detection task of simulated nodules in chest radiography. The results indicated that the use of heavy metal filters can improve detectability of simulated nodules over that obtainable with conventional copper and aluminum filter. (author)

  13. Controlling Stormwater Quality with Filter Soil—Event and Dry Weather Testing

    Directory of Open Access Journals (Sweden)

    Karin Cederkvist

    2016-08-01

    Full Text Available The use of filter soil is increasing for control of quality of stormwater runoff prior to infiltration or discharge. This study aimed to gain knowledge about treatment efficacy of filter soils at field scale. Percolate samples from swale-trench systems with filter soil based on agricultural till with/without limestone were monitored for 15 and 9 rain events respectively. Further, two curb extensions with filter soil based on landfill soil were monitored for 10 and 8 events. Pollutant concentrations in percolate were compared to influent samples from the catchment area. Additionally one of the curb extensions was tested twice by adding high-dose synthetic influent containing runoff pollutants of concern. Despite generally low influent pollutant levels, phosphorus, copper, zinc, lead and some polyaromatic hydrocarbons exceeded guiding criteria for protection of groundwater and freshwater. Concentrations in the percolate were in most cases reduced, but phosphorus increased and despite reduced concentrations copper, lead and benzo(apyrene still exceeded guiding criteria. Pollutants from the synthetic influent were efficiently retained, except the pesticide MCPA. Filter soil based on landfill soil tended to perform better than agricultural till. No impact of limestone was observed. Overall the filter soils performed well in retaining pollutants, despite simultaneous processes of mobilization and immobilization.

  14. Evaluation of MIT-SCAN-T2 for Thickness Quality Control for PCC and HMA Pavements

    Science.gov (United States)

    2018-02-01

    Thickness is currently a pay item for PCC pavements and a quality control item for both PCC and HMA pavements. A change in pavement thickness of 0.5 in. can result in a change of multiple years of service. Current thickness measurements are performed...

  15. Sensory Pollution from Bag Filters, Carbon Filters and Combinations

    DEFF Research Database (Denmark)

    Bekö, Gabriel; Clausen, Geo; Weschler, Charles J.

    2008-01-01

    by an upstream pre-filter (changed monthly), an EU7 filter protected by an upstream activated carbon (AC) filter, and EU7 filters with an AC filter either downstream or both upstream and downstream. In addition, two types of stand-alone combination filters were evaluated: a bag-type fiberglass filter...... that contained AC and a synthetic fiber cartridge filter that contained AC. Air that had passed through used filters was most acceptable for those sets in which an AC filter was used downstream of the particle filter. Comparable air quality was achieved with the stand-alone bag filter that contained AC...

  16. Improving indoor air quality and thermal comfort in office building by using combination filters

    Science.gov (United States)

    Kabrein, H.; Yusof, M. Z. M.; Hariri, A.; Leman, A. M.; Afandi, A.

    2017-09-01

    Poor indoor air quality and thermal comfort condition in the workspace affected the occupants’ health and work productivity, especially when adapting the recirculation of air in heating ventilation and air-conditioning (HVAC) system. The recirculation of air was implemented in this study by mixing the circulated returned indoor air with the outdoor fresh air. The aims of this study are to assess the indoor thermal comfort and indoor air quality (IAQ) in the office buildings, equipped with combination filters. The air filtration technique consisting minimum efficiency reporting value (MERV) filter and activated carbon fiber (ACF) filter, located before the fan coil units. The findings of the study show that the technique of mixing recirculation air with the fresh air through the combination filters met the recommended thermal comfort condition in the workspace. Furthermore, the result of the post-occupancy evaluation (POE) and the environmental measurements comply with the ASHRAE 55 standard. In addition, the level of CO2 concentration continued to decrease during the period of the measurement.

  17. The influence of software filtering in digital mammography image quality

    Science.gov (United States)

    Michail, C.; Spyropoulou, V.; Kalyvas, N.; Valais, I.; Dimitropoulos, N.; Fountos, G.; Kandarakis, I.; Panayiotakis, G.

    2009-05-01

    Breast cancer is one of the most frequently diagnosed cancers among women. Several techniques have been developed to help in the early detection of breast cancer such as conventional and digital x-ray mammography, positron and single-photon emission mammography, etc. A key advantage in digital mammography is that images can be manipulated as simple computer image files. Thus non-dedicated commercially available image manipulation software can be employed to process and store the images. The image processing tools of the Photoshop (CS 2) software usually incorporate digital filters which may be used to reduce image noise, enhance contrast and increase spatial resolution. However, improving an image quality parameter may result in degradation of another. The aim of this work was to investigate the influence of three sharpening filters, named hereafter sharpen, sharpen more and sharpen edges on image resolution and noise. Image resolution was assessed by means of the Modulation Transfer Function (MTF).In conclusion it was found that the correct use of commercial non-dedicated software on digital mammograms may improve some aspects of image quality.

  18. The influence of software filtering in digital mammography image quality

    International Nuclear Information System (INIS)

    Michail, C; Spyropoulou, V; Valais, I; Panayiotakis, G; Kalyvas, N; Fountos, G; Kandarakis, I; Dimitropoulos, N

    2009-01-01

    Breast cancer is one of the most frequently diagnosed cancers among women. Several techniques have been developed to help in the early detection of breast cancer such as conventional and digital x-ray mammography, positron and single-photon emission mammography, etc. A key advantage in digital mammography is that images can be manipulated as simple computer image files. Thus non-dedicated commercially available image manipulation software can be employed to process and store the images. The image processing tools of the Photoshop (CS 2) software usually incorporate digital filters which may be used to reduce image noise, enhance contrast and increase spatial resolution. However, improving an image quality parameter may result in degradation of another. The aim of this work was to investigate the influence of three sharpening filters, named hereafter sharpen, sharpen more and sharpen edges on image resolution and noise. Image resolution was assessed by means of the Modulation Transfer Function (MTF).In conclusion it was found that the correct use of commercial non-dedicated software on digital mammograms may improve some aspects of image quality.

  19. Physiologic quality of sweet maize seeds according to thickness and width

    Directory of Open Access Journals (Sweden)

    Claudemir Zucareli

    2014-03-01

    Full Text Available Sweet maize seeds present lower physiologic quality, when compared to regular maize seeds, due to the influence of several features, such as the seed size and shape. Thus, this study aimed at evaluating the seed physiologic quality of two sweet maize cultivars (BR-401 and BR-402, separately classified according to thickness, by using slotted screen sieves (8/64" x 3/4, 9/64" x 3/4, 10/64" x 3/4, 11/64" x 3/4, 12/64" x 3/4 and 13/64" x 3/4, and width, with round screen sieves (17/64", 18/64", 19/64", 20/64", 21/64" and 22/64". For each cultivar, sorted lots were compared with the unrated batch, following a completely randomized design, in a 2x7 factorial scheme, with four replications. The biometric parameters evaluated were sieve retention, 100 seeds weight and water content. The physiologic quality was determined according to the first counting, germination, cold test, accelerated aging, electric conductivity and seedling emergence in the field. The classification with sieves improved the physiologic quality of sweet maize seeds. Seeds with intermediate thickness, for both cultivars, generally presented greater vigor. Concerning width, larger seeds, for the BR-401 cultivar, and intermediate seeds, for the BR-402 cultivar, showed better physiologic quality.

  20. Development of nuclear safety class filter elements with long life and high quality

    International Nuclear Information System (INIS)

    Zhang Jinghua

    2009-04-01

    This paper describes the development on nuclear safety class filter elements with long life and high quality used for collecting radioactive contaminants, fragments of resin and impurities in primary systems of NPPs. The filter elements made of glass fibre elements are used for PWR, and of paper elements are used for PHWR. During the research, a series of tests for optimization were performed for selection of filter material and the improvement of binder. The flow rate and comprehensive performance have been measured in simulated conditions. The result shows that the application requirements for operational NPPs can be met, and the reliability and safety of the frame are also be verified. The comprehensive performance of the filter elements is equivalent to that of oversea similar products. The products have been used in NPPs in operation. (authors)

  1. Hybrid power filter for advanced power quality in industrial systems

    Czech Academy of Sciences Publication Activity Database

    Švec, J.; Müller, Z.; Kasembe, A. G.; Tlustý, J.; Valouch, Viktor

    2013-01-01

    Roč. 103, october 2013 (2013), s. 157-167 ISSN 0378-7796 R&D Projects: GA AV ČR IAA200760703 Institutional research plan: CEZ:AV0Z20570509 Institutional support: RVO:61388998 Keywords : hybrid power filter * power quality * industrial system Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.595, year: 2013 http://www.sciencedirect.com/science/article/pii/S0378779613001417

  2. Imaging and thickness measurement of amorphous intergranular films using TEM

    International Nuclear Information System (INIS)

    MacLaren, I.

    2004-01-01

    Fresnel fringe analysis is shown to be unreliable for grain boundaries in yttrium-doped alumina: the determined thicknesses do not agree well with those measured from high resolution transmission electron microscopy (HRTEM), the asymmetry between under- and overfocus is very large, and Fresnel fringes are sometimes shown at boundaries which contain no amorphous film. An alternative approach to the analysis of HRTEM images of grain boundary films is demonstrated: Fourier filtering is used to remove the lattice fringes from the image thereby significantly enhancing the visibility of the intergranular films. The apparent film thickness shows a discrepancy between measurements from the original HRTEM image and the filtered image. It was shown that fringe delocalisation and diffuseness of the amorphous/crystalline interfaces will lead to a significant underestimate of the thickness in unprocessed HRTEM images. In contrast to this, the average thickness can be much more accurately measured from the Fourier-filtered image, provided the boundary is oriented accurately edge-on

  3. Filtered region of interest cone-beam rotational angiography

    International Nuclear Information System (INIS)

    Schafer, Sebastian; Noeel, Peter B.; Walczak, Alan M.; Hoffmann, Kenneth R.

    2010-01-01

    Purpose: Cone-beam rotational angiography (CBRA) is widely used in the modern clinical settings. In a number of procedures, the area of interest is often considerably smaller than the field of view (FOV) of the detector, subjecting the patient to potentially unnecessary x-ray dose. The authors therefore propose a filter-based method to reduce the dose in the regions of low interest, while supplying high image quality in the region of interest (ROI). Methods: For such procedures, the authors propose a method of filtered region of interest (FROI)-CBRA. In the authors' approach, a gadolinium filter with a circular central opening is placed into the x-ray beam during image acquisition. The central region is imaged with high contrast, while peripheral regions are subjected to a substantial lower intensity and dose through beam filtering. The resulting images contain a high contrast/intensity ROI, as well as a low contrast/intensity peripheral region, and a transition region in between. To equalize the two regions' intensities, the first projection of the acquisition is performed with and without the filter in place. The equalization relationship, based on Beer's law, is established through linear regression using corresponding filtered and nonfiltered data. The transition region is equalized based on radial profiles. Results: Evaluations in 2D and 3D show no visible difference between conventional FROI-CBRA projection images and reconstructions in the ROI. CNR evaluations show similar image quality in the ROI, with a reduced CNR in the reconstructed peripheral region. In all filtered projection images, the scatter fraction inside the ROI was reduced. Theoretical and experimental dose evaluations show a considerable dose reduction; using a ROI half the original FOV reduces the dose by 60% for the filter thickness of 1.29 mm. Conclusions: These results indicate the potential of FROI-CBRA to reduce the dose to the patient while supplying the physician with the desired

  4. Filtered region of interest cone-beam rotational angiography

    Energy Technology Data Exchange (ETDEWEB)

    Schafer, Sebastian; Noeel, Peter B.; Walczak, Alan M.; Hoffmann, Kenneth R. [Department of Mechanical Engineering, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States); Department of Neurosurgery, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States) and Toshiba Stroke Research Center, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States); Department of Neurosurgery, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States); Department of Computer Science, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States) and Toshiba Stroke Research Center, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States); Department of Neurosurgery, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 and Toshiba Stroke Research Center, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States); Department of Mechanical Engineering, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States); Department of Neurosurgery, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States); Department of Computer Science, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States) and Toshiba Stroke Research Center, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States)

    2010-02-15

    Purpose: Cone-beam rotational angiography (CBRA) is widely used in the modern clinical settings. In a number of procedures, the area of interest is often considerably smaller than the field of view (FOV) of the detector, subjecting the patient to potentially unnecessary x-ray dose. The authors therefore propose a filter-based method to reduce the dose in the regions of low interest, while supplying high image quality in the region of interest (ROI). Methods: For such procedures, the authors propose a method of filtered region of interest (FROI)-CBRA. In the authors' approach, a gadolinium filter with a circular central opening is placed into the x-ray beam during image acquisition. The central region is imaged with high contrast, while peripheral regions are subjected to a substantial lower intensity and dose through beam filtering. The resulting images contain a high contrast/intensity ROI, as well as a low contrast/intensity peripheral region, and a transition region in between. To equalize the two regions' intensities, the first projection of the acquisition is performed with and without the filter in place. The equalization relationship, based on Beer's law, is established through linear regression using corresponding filtered and nonfiltered data. The transition region is equalized based on radial profiles. Results: Evaluations in 2D and 3D show no visible difference between conventional FROI-CBRA projection images and reconstructions in the ROI. CNR evaluations show similar image quality in the ROI, with a reduced CNR in the reconstructed peripheral region. In all filtered projection images, the scatter fraction inside the ROI was reduced. Theoretical and experimental dose evaluations show a considerable dose reduction; using a ROI half the original FOV reduces the dose by 60% for the filter thickness of 1.29 mm. Conclusions: These results indicate the potential of FROI-CBRA to reduce the dose to the patient while supplying the physician with

  5. Investigation of the influence of image reconstruction filter and scan parameters on operation of automatic tube current modulation systems for different CT scanners

    International Nuclear Information System (INIS)

    Sookpeng, Supawitoo; Martin, Colin J.; Gentle, David J.

    2015-01-01

    Variation in the user selected CT scanning parameters under automatic tube current modulation (ATCM) between hospitals has a substantial influence on the radiation doses and image quality for patients. The aim of this study was to investigate the effect of changing image reconstruction filter and scan parameter settings on tube current, dose and image quality for various CT scanners operating under ATCM. The scan parameters varied were pitch factor, rotation time, collimator configuration, kVp, image thickness and image filter convolution (FC) used for reconstruction. The Toshiba scanner varies the tube current to achieve a set target noise. Changes in the FC setting and image thickness for the first reconstruction were the major factors affecting patient dose. A two-step change in FC from smoother to sharper filters doubles the dose, but is counterbalanced by an improvement in spatial resolution. In contrast, Philips and Siemens scanners maintained tube current values similar to those for a reference image and patient, and the tube current only varied slightly for changes in individual CT scan parameters. The selection of a sharp filter increased the image noise, while use of iDose iterative reconstruction reduced the noise. Since the principles used by CT manufacturers for ATCM vary, it is important that parameters which affect patient dose and image quality for each scanner are made clear to operator to aid in optimisation. (authors)

  6. Determination of equivalent copper thickness of patient equivalent phantoms in terms of attenuation, used in radiology

    International Nuclear Information System (INIS)

    Jansen, J.Th.M.; Suliman, I.I.; Zoetelief, J.

    2002-01-01

    aluminium filtration. The Monte Carlo N-Particle transport code (MCNP) is used to calculate the attenuation in the different geometries with the PMMA or copper or no filters applied. In all these cases the detector is placed at 1.0005 m distance from the focus on the central beam axis, with all filters between the detector and the focus. No anti-scatter grid is used in these calculations. With different thickness of the PMMA phantom and appropriate tube voltage the attenuation is calculated. The copper filter thickness is adjusted to get the same attenuation as obtained with the relevant PMMA phantoms. This match is made for the PMMA-phantom in front of the image intensifier and the copper filter in front of the image intensifier or attached to the X-ray tube diaphragm. In addition a match is made with both the PMMA and copper filter attached to the X-ray tube diaphragm. The image intensifier is simulated by a CsI plate 0.5 mm thickness, placed at 1.001 m from the focus. The front filters are placed 0.15 m from the focus and the back filters are ending 1.00 m from the focus. The results will be presented as the copper equivalent filter thickness for the PMMA phantom thicknesses mentioned above for different tube voltages and both beam geometries. The situation with both the PMMA phantom and copper filter in the back position is used to estimate the patient entrance surface dose rates. The equivalent copper filter calculation is based on the detector behind the attenuators to simulate the performance of an Automatic Exposure Controller (AEC). In addition detectors are placed 0.5 mm in front of the PMMA phantom and the copper filter and corrected by the inverse square law to a focus detector distance of 0.50 m. Comparison between both situations is made to estimate the uncertainty in the ionisation chamber measurement. The equivalent copper filter is based on equal attenuation therefore the beam quality will, in general, be different. In order to characterise these

  7. Device quality ZnO grown using a Filtered Cathodic Vacuum Arc

    International Nuclear Information System (INIS)

    Elzwawi, Salim; Kim, Hyung Suk; Heinhold, Robert; Lynam, Max; Turner, Gary; Partridge, Jim G.; McCulloch, Dougal G.

    2012-01-01

    In this paper we report on the structural, electrical and optical characteristics of unintentionally doped ZnO films grown on a-plane sapphire substrates using the Filtered Cathodic Vacuum Arc (FCVA) technique. The resulting films showed considerable promise for device applications with properties including high transparency, moderate intrinsic carrier concentrations (10 17 -10 19 cm -3 ), electron mobilities up to 30 cm 2 /Vs, low surface roughness (typically <2% of film thickness) and well-structured photoluminescence. Post-annealing in oxygen at temperatures up to 800 °C produced significant improvements in the properties of these films. Silver oxide Schottky diodes fabricated on FCVA ZnO showed ideality factors as low as 1.20 and good sensitivity to ultraviolet light.

  8. Measurement of Water Quality Parameters for Before and After Maintenance Service in Water Filter System

    Directory of Open Access Journals (Sweden)

    Shaharudin Nuraida

    2017-01-01

    Full Text Available An adequate supply of safe drinking water is one of major ways to obtain healthy life. Water filter system is one way to improve the water quality. However, to maintain the performance of the system, it need to undergo the maintenance service. This study evaluate the requirement of maintenance service in water filter system. Water quality was measured before and after maintenance service. Parameters measured were pH, turbidity, residual chlorine, nitrate and heavy metals and these parameters were compared with National Drinking Water Quality Standards. Collection of data were involved three housing areas in Johor. The quality of drinking water from water filter system were analysed using pH meter, turbidity meter, DR6000 and Inductively Coupled Plasma-Mass Spectrometer. pH value was increased from 16.4% for before maintenance services to 30.7% for after maintenance service. Increment of removal percentage for turbidity, residual chlorine and nitrate after maintenance were 21.5, 13.6 and 26.7, respectively. This result shows that maintenance service enhance the performance of the system. However, less significant of maintenance service for enhance the removal of heavy metals which the increment of removal percentage in range 0.3 to 9.8. Only aluminium shows percentage removal for after maintenance with 92.8% lower compared to before maintenance service with 95.5%.

  9. Hydraulic modeling of clay ceramic water filters for point-of-use water treatment.

    Science.gov (United States)

    Schweitzer, Ryan W; Cunningham, Jeffrey A; Mihelcic, James R

    2013-01-02

    The acceptability of ceramic filters for point-of-use water treatment depends not only on the quality of the filtered water, but also on the quantity of water the filters can produce. This paper presents two mathematical models for the hydraulic performance of ceramic water filters under typical usage. A model is developed for two common filter geometries: paraboloid- and frustum-shaped. Both models are calibrated and evaluated by comparison to experimental data. The hydraulic models are able to predict the following parameters as functions of time: water level in the filter (h), instantaneous volumetric flow rate of filtrate (Q), and cumulative volume of water produced (V). The models' utility is demonstrated by applying them to estimate how the volume of water produced depends on factors such as the filter shape and the frequency of filling. Both models predict that the volume of water produced can be increased by about 45% if users refill the filter three times per day versus only once per day. Also, the models predict that filter geometry affects the volume of water produced: for two filters with equal volume, equal wall thickness, and equal hydraulic conductivity, a filter that is tall and thin will produce as much as 25% more water than one which is shallow and wide. We suggest that the models can be used as tools to help optimize filter performance.

  10. Investigation of New Microstrip Bandpass Filter Based on Patch Resonator with Geometrical Fractal Slot.

    Directory of Open Access Journals (Sweden)

    Yaqeen S Mezaal

    Full Text Available A compact dual-mode microstrip bandpass filter using geometrical slot is presented in this paper. The adopted geometrical slot is based on first iteration of Cantor square fractal curve. This filter has the benefits of possessing narrower and sharper frequency responses as compared to microstrip filters that use single mode resonators and traditional dual-mode square patch resonators. The filter has been modeled and demonstrated by Microwave Office EM simulator designed at a resonant frequency of 2 GHz using a substrate of εr = 10.8 and thickness of h = 1.27 mm. The output simulated results of the proposed filter exhibit 22 dB return loss, 0.1678 dB insertion loss and 12 MHz bandwidth in the passband region. In addition to the narrow band gained, miniaturization properties as well as weakened spurious frequency responses and blocked second harmonic frequency in out of band regions have been acquired. Filter parameters including insertion loss, return loss, bandwidth, coupling coefficient and external quality factor have been compared with different values of perturbation dimension (d. Also, a full comparative study of this filter as compared with traditional square patch filter has been considered.

  11. Bowtie filters for dedicated breast CT: Analysis of bowtie filter material selection

    Energy Technology Data Exchange (ETDEWEB)

    Kontson, Kimberly, E-mail: Kimberly.Kontson@fda.hhs.gov; Jennings, Robert J. [Department of Bioengineering, University of Maryland, College Park, Maryland 20742 and Division of Imaging and Applied Mathematics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, U.S. Food and Drug Administration, 10903 New Hampshire Avenue, Silver Spring, Maryland 20993 (United States)

    2015-09-15

    Purpose: For a given bowtie filter design, both the selection of material and the physical design control the energy fluence, and consequently the dose distribution, in the object. Using three previously described bowtie filter designs, the goal of this work is to demonstrate the effect that different materials have on the bowtie filter performance measures. Methods: Three bowtie filter designs that compensate for one or more aspects of the beam-modifying effects due to the differences in path length in a projection have been designed. The nature of the designs allows for their realization using a variety of materials. The designs were based on a phantom, 14 cm in diameter, composed of 40% fibroglandular and 60% adipose tissue. Bowtie design #1 is based on single material spectral matching and produces nearly uniform spectral shape for radiation incident upon the detector. Bowtie design #2 uses the idea of basis-material decomposition to produce the same spectral shape and intensity at the detector, using two different materials. With bowtie design #3, it is possible to eliminate the beam hardening effect in the reconstructed image by adjusting the bowtie filter thickness so that the effective attenuation coefficient for every ray is the same. Seven different materials were chosen to represent a range of chemical compositions and densities. After calculation of construction parameters for each bowtie filter design, a bowtie filter was created using each of these materials (assuming reasonable construction parameters were obtained), resulting in a total of 26 bowtie filters modeled analytically and in the PENELOPE Monte Carlo simulation environment. Using the analytical model of each bowtie filter, design profiles were obtained and energy fluence as a function of fan-angle was calculated. Projection images with and without each bowtie filter design were also generated using PENELOPE and reconstructed using FBP. Parameters such as dose distribution, noise uniformity

  12. Bowtie filters for dedicated breast CT: Analysis of bowtie filter material selection

    International Nuclear Information System (INIS)

    Kontson, Kimberly; Jennings, Robert J.

    2015-01-01

    Purpose: For a given bowtie filter design, both the selection of material and the physical design control the energy fluence, and consequently the dose distribution, in the object. Using three previously described bowtie filter designs, the goal of this work is to demonstrate the effect that different materials have on the bowtie filter performance measures. Methods: Three bowtie filter designs that compensate for one or more aspects of the beam-modifying effects due to the differences in path length in a projection have been designed. The nature of the designs allows for their realization using a variety of materials. The designs were based on a phantom, 14 cm in diameter, composed of 40% fibroglandular and 60% adipose tissue. Bowtie design #1 is based on single material spectral matching and produces nearly uniform spectral shape for radiation incident upon the detector. Bowtie design #2 uses the idea of basis-material decomposition to produce the same spectral shape and intensity at the detector, using two different materials. With bowtie design #3, it is possible to eliminate the beam hardening effect in the reconstructed image by adjusting the bowtie filter thickness so that the effective attenuation coefficient for every ray is the same. Seven different materials were chosen to represent a range of chemical compositions and densities. After calculation of construction parameters for each bowtie filter design, a bowtie filter was created using each of these materials (assuming reasonable construction parameters were obtained), resulting in a total of 26 bowtie filters modeled analytically and in the PENELOPE Monte Carlo simulation environment. Using the analytical model of each bowtie filter, design profiles were obtained and energy fluence as a function of fan-angle was calculated. Projection images with and without each bowtie filter design were also generated using PENELOPE and reconstructed using FBP. Parameters such as dose distribution, noise uniformity

  13. The Astro-E/XRS Blocking Filter Calibration

    Science.gov (United States)

    Audley, Michael D.; Arnaud, Keith A.; Gendreau, Keith C.; Boyce, Kevin R.; Fleetwood, Charles M.; Kelley, Richard L.; Keski-Kuha, Ritva A.; Porter, F. Scott; Stahle, Caroline K.; Szymkowiak, Andrew E.

    1999-01-01

    We describe the transmission calibration of the Astro-E XRS blocking filters. The XRS instrument has five aluminized polyimide blocking filters. These filters are located at thermal stages ranging from 200 K to 60 mK. They are each about 1000 A thick. XRS will have high energy resolution which will enable it to see some of the extended fine structure around the oxygen and aluminum K edges of these filters. Thus, we are conducting a high spectral resolution calibration of the filters near these energies to resolve out extended flue structure and absorption lines.

  14. Numerical study of canister filters with alternatives filter cap configurations

    Science.gov (United States)

    Mohammed, A. N.; Daud, A. R.; Abdullah, K.; Seri, S. M.; Razali, M. A.; Hushim, M. F.; Khalid, A.

    2017-09-01

    Air filtration system and filter play an important role in getting a good quality air into turbo machinery such as gas turbine. The filtration system and filter has improved the quality of air and protect the gas turbine part from contaminants which could bring damage. During separation of contaminants from the air, pressure drop cannot be avoided but it can be minimized thus helps to reduce the intake losses of the engine [1]. This study is focused on the configuration of the filter in order to obtain the minimal pressure drop along the filter. The configuration used is the basic filter geometry provided by Salutary Avenue Manufacturing Sdn Bhd. and two modified canister filter cap which is designed based on the basic filter model. The geometries of the filter are generated by using SOLIDWORKS software and Computational Fluid Dynamics (CFD) software is used to analyse and simulates the flow through the filter. In this study, the parameters of the inlet velocity are 0.032 m/s, 0.063 m/s, 0.094 m/s and 0.126 m/s. The total pressure drop produce by basic, modified filter 1 and 2 is 292.3 Pa, 251.11 Pa and 274.7 Pa. The pressure drop reduction for the modified filter 1 is 41.19 Pa and 14.1% lower compared to basic filter and the pressure drop reduction for modified filter 2 is 17.6 Pa and 6.02% lower compared to the basic filter. The pressure drops for the basic filter are slightly different with the Salutary Avenue filter due to limited data and experiment details. CFD software are very reliable in running a simulation rather than produces the prototypes and conduct the experiment thus reducing overall time and cost in this study.

  15. DAF: differential ACE filtering image quality assessment by automatic color equalization

    Science.gov (United States)

    Ouni, S.; Chambah, M.; Saint-Jean, C.; Rizzi, A.

    2008-01-01

    Ideally, a quality assessment system would perceive and measure image or video impairments just like a human being. But in reality, objective quality metrics do not necessarily correlate well with perceived quality [1]. Plus, some measures assume that there exists a reference in the form of an "original" to compare to, which prevents their usage in digital restoration field, where often there is no reference to compare to. That is why subjective evaluation is the most used and most efficient approach up to now. But subjective assessment is expensive, time consuming and does not respond, hence, to the economic requirements [2,3]. Thus, reliable automatic methods for visual quality assessment are needed in the field of digital film restoration. The ACE method, for Automatic Color Equalization [4,6], is an algorithm for digital images unsupervised enhancement. It is based on a new computational approach that tries to model the perceptual response of our vision system merging the Gray World and White Patch equalization mechanisms in a global and local way. Like our vision system ACE is able to adapt to widely varying lighting conditions, and to extract visual information from the environment efficaciously. Moreover ACE can be run in an unsupervised manner. Hence it is very useful as a digital film restoration tool since no a priori information is available. In this paper we deepen the investigation of using the ACE algorithm as a basis for a reference free image quality evaluation. This new metric called DAF for Differential ACE Filtering [7] is an objective quality measure that can be used in several image restoration and image quality assessment systems. In this paper, we compare on different image databases, the results obtained with DAF and with some subjective image quality assessments (Mean Opinion Score MOS as measure of perceived image quality). We study also the correlation between objective measure and MOS. In our experiments, we have used for the first image

  16. UV Fluorescence Photography of Works of Art : Replacing the Traditional UV Cut Filters with Interference Filters

    Directory of Open Access Journals (Sweden)

    Luís BRAVO PEREIRA

    2010-09-01

    Full Text Available For many years filters like the Kodak Wratten E series, or the equivalent Schneider B+W 415, were used as standard UV cut filters, necessary to obtain good quality on UV Fluorescence photography. The only problem with the use of these filters is that, when they receive the UV radiation that they should remove, they present themselves an internal fluorescence as side effect, that usually reduce contrast and quality on the final image. This article presents the results of our experiences on using some innovative filters, that appeared available on the market in recent years, projected to adsorb UV radiation even more efficiently than with the mentioned above pigment based standard filters: the interference filters for UV rejection (and, usually, for IR rejection too manufactured using interference layers, that present better results than the pigment based filters. The only problem with interference filters type is that they are sensitive to the rays direction and, because of that, they are not adequate to wide-angle lenses. The internal fluorescence for three filters: the B+W 415 UV cut (equivalent to the Kodak Wratten 2E, pigment based, the B+W 486 UV IR cut (an interference type filter, used frequently on digital cameras to remove IR or UV and the Baader UVIR rejection filter (two versions of this interference filter were used had been tested and compared. The final quality of the UV fluorescence images seems to be of a superior quality when compared to the images obtained with classic filters.

  17. Improving indoor air quality by using the new generation of corrugated cardboard-based filters.

    Science.gov (United States)

    Candiani, Gabriele; Del Curto, Barbara; Cigada, Alberto

    2012-09-27

    Indoor Air Quality (IAQ) is strictly affected by the concentration of total suspended particulate matter (TSP). Air filtration is by far the most feasible suggestion to improve IAQ. Unfortunately, highly effective HEPA filters also have a few major weaknesses that have hindered their widespread use. There is therefore a renewed interest in developing novel, cost-effective filtration systems. We have recently reported the development of cardboard-based filters for bacterial removal that were further implemented and tested herein. A parallelepiped filter manufactured by aligning strips of corrugated cardboard and surrounded by a cardboard frame was specifically designed with an internal pocket holding a partially cut antistatic pleated fabric (HP). This filter, together with its parent version (CTRL) and a commercially sourced specimen (CAF), were assessed comparatively in a long-time test to assess their effectiveness on TSP removal. We found that the TSP abatement efficiency (E%) of the HP filter was relatively high and invariable over the 93 days of test and the pressure drop (PD%) decrease because of filter clogging was moderate. Most important, the HP filter was the most effective if assessed in terms of overall yield (Y%) and its performance was quite constant over the entire period considered. This work disclosed this novel class of corrugated cardboard-based filters as promising tools to ameliorate IAQ in light of their good TSP removal properties that endure over time. Moreover, cardboard is a lightweight, inexpensive, and eco-friendly material and corrugated cardboard-based air filters are very easy to shape and mount on and/or replace in existing ventilation systems.

  18. WE-DE-207B-08: Towards Standardization of X-Ray Filters in Digital Mammography-Enabled Breast Tomosynthesis Systems

    International Nuclear Information System (INIS)

    Shrestha, S; Vedantham, S; Karellas, A

    2016-01-01

    Purpose: In digital breast tomosynthesis (DBT) systems capable of digital mammography (DM), Al filters are used during DBT and K-edge filters during DM. The potential for standardizing the x-ray filters with Al, instead of K-edge filters, was investigated with intent to reduce exposure duration and to promote a simpler system design. Methods: Analytical computations of the half-value thickness (HVT) and the photon fluence per mAs (photons/mm2/mAs) for K-edge filters (50µm Rh; 50µm Ag) were compared with Al filters of varying thickness. Two strategies for matching the HVT from K-edge and Al filtered spectra were investigated: varying the kVp for fixed Al thickness, or varying the Al thickness at matched kVp. For both strategies, Al filters were an order of magnitude thicker than K-edge filters. Hence, Monte Carlo simulations were conducted with the GEANT4 toolkit to determine if the scatter-to-primary ratio (SPR) and the point spread function of scatter (scatter PSF) differed between Al and K-edge filters. Results: Results show the potential for replacing currently used Kedge filters with Al. For fixed Al thickness (700µm), ±1 kVp and +(1–3) kVp change, matched HVT of Rh and Ag filtered spectra. At matched kVp, Al thickness range (650,750)µm and (750,860)µm matched the HVT from Rh and Ag filtered spectra. Photon fluence/mAs with Al filters were 1.5–2.5 times higher, depending on kVp and Al thickness, compared to K-edge filters. Although Al thickness was an order higher than K-edge filters, neither the SPR nor the scatter PSF differed from K-edge filters. Conclusion: The use of Al filters for digital mammography is potentially feasible. The increased fluence/mAs with Al could decrease exposure duration for the combined DBT+DM exam and simplify system design. Effect of x-ray spectrum change due to Al filtration on radiation dose, signal, noise, contrast and related metrics are being investigated. Funding support: Supported in part by NIH R21CA176470 and R01

  19. WE-DE-207B-08: Towards Standardization of X-Ray Filters in Digital Mammography-Enabled Breast Tomosynthesis Systems

    Energy Technology Data Exchange (ETDEWEB)

    Shrestha, S; Vedantham, S; Karellas, A [University of Massachusetts Medical School, Worcester, MA (United States)

    2016-06-15

    Purpose: In digital breast tomosynthesis (DBT) systems capable of digital mammography (DM), Al filters are used during DBT and K-edge filters during DM. The potential for standardizing the x-ray filters with Al, instead of K-edge filters, was investigated with intent to reduce exposure duration and to promote a simpler system design. Methods: Analytical computations of the half-value thickness (HVT) and the photon fluence per mAs (photons/mm2/mAs) for K-edge filters (50µm Rh; 50µm Ag) were compared with Al filters of varying thickness. Two strategies for matching the HVT from K-edge and Al filtered spectra were investigated: varying the kVp for fixed Al thickness, or varying the Al thickness at matched kVp. For both strategies, Al filters were an order of magnitude thicker than K-edge filters. Hence, Monte Carlo simulations were conducted with the GEANT4 toolkit to determine if the scatter-to-primary ratio (SPR) and the point spread function of scatter (scatter PSF) differed between Al and K-edge filters. Results: Results show the potential for replacing currently used Kedge filters with Al. For fixed Al thickness (700µm), ±1 kVp and +(1–3) kVp change, matched HVT of Rh and Ag filtered spectra. At matched kVp, Al thickness range (650,750)µm and (750,860)µm matched the HVT from Rh and Ag filtered spectra. Photon fluence/mAs with Al filters were 1.5–2.5 times higher, depending on kVp and Al thickness, compared to K-edge filters. Although Al thickness was an order higher than K-edge filters, neither the SPR nor the scatter PSF differed from K-edge filters. Conclusion: The use of Al filters for digital mammography is potentially feasible. The increased fluence/mAs with Al could decrease exposure duration for the combined DBT+DM exam and simplify system design. Effect of x-ray spectrum change due to Al filtration on radiation dose, signal, noise, contrast and related metrics are being investigated. Funding support: Supported in part by NIH R21CA176470 and R01

  20. High temperature superconducting YBCO microwave filters

    Science.gov (United States)

    Aghabagheri, S.; Rasti, M.; Mohammadizadeh, M. R.; Kameli, P.; Salamati, H.; Mohammadpour-Aghdam, K.; Faraji-Dana, R.

    2018-06-01

    Epitaxial thin films of YBCO high temperature superconductor are widely used in telecommunication technology such as microwave filter, antenna, coupler and etc., due to their lower surface resistance and lower microwave loss than their normal conductor counterparts. Thin films of YBCO were fabricated by PLD technique on LAO substrate. Transition temperature and width were 88 K and 3 K, respectively. A filter pattern was designed and implemented by wet photolithography method on the films. Characterization of the filter at 77 K has been compared with the simulation results and the results for a made gold filter. Both YBCO and gold filters show high microwave loss. For YBCO filter, the reason may be due to the improper contacts on the feedlines and for gold filter, low thickness of the gold film has caused the loss increased.

  1. FIONDA (Filtering Images of Niobium Disks Application): Filter application for Eddy Current Scanner data analysis

    International Nuclear Information System (INIS)

    Boffo, C.; Bauer, P.

    2005-01-01

    As part of the material QC process, each Niobium disk from which a superconducting RF cavity is built must undergo an eddy current scan [1]. This process allows to discover embedded defects in the material that are not visible to the naked eye because too small or under the surface. Moreover, during the production process of SC cavities the outer layer of Nb is removed via chemical or electro-chemical etching, thus it is important to evaluate the quality of the subsurface layer (in the order of 100nm) where superconductivity will happen. The reference eddy current scanning machine is operated at DESY; at Fermilab we are using the SNS eddy current scanner on loan, courtesy of SNS. In the past year, several upgrades were implemented aiming at raising the SNS machine performance to that of the DESY reference machine [2]. As part of this effort an algorithm that enables the filtering of the results of the scans and thus improves the resolution of the process was developed. The description of the algorithm and of the software used to filter the scan results is presented in this note. This filter application is a useful tool when the coupling between the signal associated to the long range probe distance (or sample thickness) variation and that associated to inclusions masks the presence of defects. Moreover instead of using indirect criteria (such as appearance on screen), the filter targets precisely the topology variations of interest. This application is listed in the FermiTools database and is freely available

  2. Synthesis and physical properties of zinc-oxide textured films by using a filtered preheated hydrothermal

    International Nuclear Information System (INIS)

    Qiu, Jijun; Shin, Dongmyeong; He, Weizhen; Kim, Hyungkook; Hwang, Yoonhwae; Li, Xiaomin; Gao, Xiangdong

    2014-01-01

    Axially (c-axis)-oriented ZnO thick films with a ∼8.1 μm thickness were fabricated on ZnO seed layer coated substrates by using a filtered preheated hydrothermal solution. The thick films composed of single-crystal ZnO microrods with various diameters were formed by coalescing each nanorod together along their side surfaces. From the X-ray diffraction result a biaxial stress exists was found to exist in the as-grown thick films, and the stress gradually increased with increasing annealing temperatures from 200 to 550 .deg. C due to a degradation in the crystalline quality. The biaxial stress is responsible for the red-shift of the optical band gap of the ZnO thick films. Photoluminescence and Hall results revealed that the optical and the electrical properties of the thick films were degenerated after high-temperature annealing (> 200 .deg. C), which was due to the introduction of point defects, such as oxygen interstitials and zinc vacancies.

  3. Synthesis and physical properties of zinc-oxide textured films by using a filtered preheated hydrothermal

    Energy Technology Data Exchange (ETDEWEB)

    Qiu, Jijun [Pusan National University, Busan (Korea, Republic of); Shin, Dongmyeong; He, Weizhen; Kim, Hyungkook; Hwang, Yoonhwae [Pusan National University, Miryang (Korea, Republic of); Li, Xiaomin; Gao, Xiangdong [Chinese Academy of Sciences, Shanghai (China)

    2014-11-15

    Axially (c-axis)-oriented ZnO thick films with a ∼8.1 μm thickness were fabricated on ZnO seed layer coated substrates by using a filtered preheated hydrothermal solution. The thick films composed of single-crystal ZnO microrods with various diameters were formed by coalescing each nanorod together along their side surfaces. From the X-ray diffraction result a biaxial stress exists was found to exist in the as-grown thick films, and the stress gradually increased with increasing annealing temperatures from 200 to 550 .deg. C due to a degradation in the crystalline quality. The biaxial stress is responsible for the red-shift of the optical band gap of the ZnO thick films. Photoluminescence and Hall results revealed that the optical and the electrical properties of the thick films were degenerated after high-temperature annealing (> 200 .deg. C), which was due to the introduction of point defects, such as oxygen interstitials and zinc vacancies.

  4. Micro-particle filter made in SU-8 for biomedical applications

    DEFF Research Database (Denmark)

    Noeth, Nadine-Nicole; Keller, Stephan Urs; Fetz, Stefanie

    2009-01-01

    We have integrated a micro-particle filter in a polymer cantilever to filter micro-particles from a fluid while simultaneously measuring the amount of filtered particles. In a 3,8 mum thick SU-8 cantilever a filter was integrated with pore sizes between 3 and 30 mum. The chip was inserted in a mi...

  5. Studies of characteristics of precoating for precoat filter using powdered ion exchange resin as filter aid

    International Nuclear Information System (INIS)

    Adachi, Tetsuro; Sawa, Toshio; Takahashi, Sankichi; Sindo, Toshikazu.

    1987-01-01

    The characteristics of precoating for a precoat filter using powdered ion exchange resin as filter aid were investigated with 1.5 meters long filter elements. The characteristics of precoating (thickness and distribution of precoat layer) were evaluated at various operating conditions. The results showed that the factors controlling them were size of resin flock and ascending velocity of water in the filter vessel. The size of resin flock was affected by reflocculation of resin flock, and operating conditions causing reflocculation were investigated. Consequently, it seemed that reflocculation depended on the maximum value of resin concentration in the filter vessel. In addition, a relation between sedimentation rate of resin flock and ascending velocity in the filter vessel was noticed by simulation of distribution of ascending velocity and effects on characteristics of precoating were evaluated. (author)

  6. Effect of Post-Reconstruction Gaussian Filtering on Image Quality and Myocardial Blood Flow Measurement with N-13 Ammonia PET

    Directory of Open Access Journals (Sweden)

    Hyeon Sik Kim

    2014-10-01

    Full Text Available Objective(s: In order to evaluate the effect of post-reconstruction Gaussian filtering on image quality and myocardial blood flow (MBF measurement by dynamic N-13 ammonia positron emission tomography (PET, we compared various reconstruction and filtering methods with image characteristics. Methods: Dynamic PET images of three patients with coronary artery disease (male-female ratio of 2:1; age: 57, 53, and 76 years were reconstructed, using filtered back projection (FBP and ordered subset expectation maximization (OSEM methods. OSEM reconstruction consisted of OSEM_2I, OSEM_4I, and OSEM_6I with 2, 4, and 6 iterations, respectively. The images, reconstructed and filtered by Gaussian filters of 5, 10, and 15 mm, were obtained, as well as non-filtered images. Visual analysis of image quality (IQ was performed using a 3-grade scoring system by 2 independent readers, blinded to the reconstruction and filtering methods of stress images. Then, signal-to-noise ratio (SNR was calculated by noise and contrast recovery (CR. Stress and rest MBF and coronary flow reserve (CFR were obtained for each method. IQ scores, stress and rest MBF, and CFR were compared between the methods, using Chi-square and Kruskal-Wallis tests. Results: In the visual analysis, IQ was significantly higher by 10 mm Gaussian filtering, compared to other sizes of filter (PP=0.923 and 0.855 for readers 1 and 2, respectively. SNR was significantly higher in 10 mm Gaussian filter. There was a significant difference in stress and rest MBF between several vascular territories. However CFR was not significantly different according to various filtering methods. Conclusion: Post-reconstruction Gaussian filtering with a filter size of 10 mm significantly enhances the IQ of N-13 ammonia PET-CT, without changing the results of CFR calculation. .

  7. Effect of Post-Reconstruction Gaussian Filtering on Image Quality and Myocardial Blood Flow Measurement with N-13 Ammonia PET

    International Nuclear Information System (INIS)

    Kim, Hyeon Sik; Cho, Sang-Geon; Kim, Ju Han; Kwon, Seong Young; Lee, Byeong-il; Bom, Hee-Seung

    2014-01-01

    In order to evaluate the effect of post-reconstruction Gaussian filtering on image quality and myocardial blood flow (MBF) measurement by dynamic N-13 ammonia positron emission tomography (PET), we compared various reconstruction and filtering methods with image characteristics. Dynamic PET images of three patients with coronary artery disease (male-female ratio of 2:1; age: 57, 53, and 76 years) were reconstructed, using filtered back projection (FBP) and ordered subset expectation maximization (OSEM) methods. OSEM reconstruction consisted of OSEM-2I, OSEM-4I, and OSEM-6I with 2, 4, and 6 iterations, respectively. The images, reconstructed and filtered by Gaussian filters of 5, 10, and 15 mm, were obtained, as well as non-filtered images. Visual analysis of image quality (IQ) was performed using a 3-grade scoring system by 2 independent readers, blinded to the reconstruction and filtering methods of stress images. Then, signal-to-noise ratio (SNR) was calculated by noise and contrast recovery (CR). Stress and rest MBF and coronary flow reserve (CFR) were obtained for each method. IQ scores, stress and rest MBF, and CFR were compared between the methods, using Chi-square and Kruskal-Wallis tests. In the visual analysis, IQ was significantly higher by 10 mm Gaussian filtering, compared to other sizes of filter (P<0.001 for both readers). However, no significant difference of IQ was found between FBP and various numbers of iteration in OSEM (P=0.923 and 0.855 for readers 1 and 2, respectively). SNR was significantly higher in 10 mm Gaussian filter. There was a significant difference in stress and rest MBF between several vascular territories. However CFR was not significantly different according to various filtering methods. Post-reconstruction Gaussian filtering with a filter size of 10 mm significantly enhances the IQ of N-13 ammonia PET-CT, without changing the results of CFR calculation

  8. Multiscale bilateral filtering for improving image quality in digital breast tomosynthesis

    Science.gov (United States)

    Lu, Yao; Chan, Heang-Ping; Wei, Jun; Hadjiiski, Lubomir M.; Samala, Ravi K.

    2015-01-01

    Purpose: Detection of subtle microcalcifications in digital breast tomosynthesis (DBT) is a challenging task because of the large, noisy DBT volume. It is important to enhance the contrast-to-noise ratio (CNR) of microcalcifications in DBT reconstruction. Most regularization methods depend on local gradient and may treat the ill-defined margins or subtle spiculations of masses and subtle microcalcifications as noise because of their small gradient. The authors developed a new multiscale bilateral filtering (MSBF) regularization method for the simultaneous algebraic reconstruction technique (SART) to improve the CNR of microcalcifications without compromising the quality of masses. Methods: The MSBF exploits a multiscale structure of DBT images to suppress noise and selectively enhance high frequency structures. At the end of each SART iteration, every DBT slice is decomposed into several frequency bands via Laplacian pyramid decomposition. No regularization is applied to the low frequency bands so that subtle edges of masses and structured background are preserved. Bilateral filtering is applied to the high frequency bands to enhance microcalcifications while suppressing noise. The regularized DBT images are used for updating in the next SART iteration. The new MSBF method was compared with the nonconvex total p-variation (TpV) method for noise regularization with SART. A GE GEN2 prototype DBT system was used for acquisition of projections at 21 angles in 3° increments over a ±30° range. The reconstruction image quality with no regularization (NR) and that with the two regularization methods were compared using the DBT scans of a heterogeneous breast phantom and several human subjects with masses and microcalcifications. The CNR and the full width at half maximum (FWHM) of the line profiles of microcalcifications and across the spiculations within their in-focus DBT slices were used as image quality measures. Results: The MSBF method reduced contouring artifacts

  9. Interactions of donor sources and media influence the histo-morphological quality of full-thickness skin models.

    Science.gov (United States)

    Lange, Julia; Weil, Frederik; Riegler, Christoph; Groeber, Florian; Rebhan, Silke; Kurdyn, Szymon; Alb, Miriam; Kneitz, Hermann; Gelbrich, Götz; Walles, Heike; Mielke, Stephan

    2016-10-01

    Human artificial skin models are increasingly employed as non-animal test platforms for research and medical purposes. However, the overall histopathological quality of such models may vary significantly. Therefore, the effects of manufacturing protocols and donor sources on the quality of skin models built-up from fibroblasts and keratinocytes derived from juvenile foreskins is studied. Histo-morphological parameters such as epidermal thickness, number of epidermal cell layers, dermal thickness, dermo-epidermal adhesion and absence of cellular nuclei in the corneal layer are obtained and scored accordingly. In total, 144 full-thickness skin models derived from 16 different donors, built-up in triplicates using three different culture conditions were successfully generated. In univariate analysis both media and donor age affected the quality of skin models significantly. Both parameters remained statistically significant in multivariate analyses. Performing general linear model analyses we could show that individual medium-donor-interactions influence the quality. These observations suggest that the optimal choice of media may differ from donor to donor and coincides with findings where significant inter-individual variations of growth rates in keratinocytes and fibroblasts have been described. Thus, the consideration of individual medium-donor-interactions may improve the overall quality of human organ models thereby forming a reproducible test platform for sophisticated clinical research. Copyright © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Faraday anomalous dispersion optical filters

    Science.gov (United States)

    Shay, T. M.; Yin, B.; Alvarez, L. S.

    1993-01-01

    The effect of Faraday anomalous dispersion optical filters on infrared and blue transitions of some alkali atoms is calculated. A composite system is designed to further increase the background noise rejection. The measured results of the solar background rejection and image quality through the filter are presented. The results show that the filter may provide high transmission and high background noise rejection with excellent image quality.

  11. Arthroscopic repair of partial-thickness and small full-thickness rotator cuff tears: tendon quality as a prognostic factor for repair integrity.

    Science.gov (United States)

    Chung, Seok Won; Kim, Jae Yoon; Yoon, Jong Pil; Lyu, Seong Hwa; Rhee, Sung Min; Oh, Se Bong

    2015-03-01

    showed a 7.64-times higher failure rate (95% CI, 1.43-36.04) than did those with a lower tendinosis grade (P = .013). All functional outcome scores improved after surgery (all P rotator cuff tears showed more severe tendinosis compared with the small full-thickness tears in this study. Contrary to previous impressions that tear size or fatty infiltration is the factor that most influences healing, tendinosis severity assessed by preoperative MRI was the only factor associated with failure to heal, given the numbers available for analysis, in patients with partial-thickness and small full-thickness rotator cuff tears. Surgeons should pay more attention to tendon quality during repair surgery or rehabilitation in smaller rotator cuff tears, especially in high-grade partial-thickness tears with severe tendinosis. © 2014 The Author(s).

  12. Transmission electron microscopy of bulk specimens over 10 µm in thickness

    Energy Technology Data Exchange (ETDEWEB)

    Sadamatsu, Sunao, E-mail: sadamatsu@mech.kagoshima-u.ac.jp [Department of Mechanical Engineering, Kagoshima University, Korimoto, Kagoshima 890-0065 (Japan); Tanaka, Masaki; Higashida, Kenji [Department of Materials Science and Engineering, Kyushu University, Nishi-ku, Fukuoka 819-0395 (Japan); Matsumura, Syo [Department of Applied Quantum Physics and Nuclear Engineering, Kyushu University, Nishi-ku, Fukuoka 819-0395 (Japan); Ultramicroscopy Research Center, Kyushu University, Nishi-ku, Fukuoka 819-0395 (Japan)

    2016-03-15

    We succeeded the observation of microstructures in bulk-sized specimens of over 10 µm in thickness by employing a technique that combines transmission electron microscopy (TEM) with energy-filtered imaging based on electron energy-loss spectroscopy (EELS). This method is unique in that it incorporates the inelastically scattered electrons into the imaging process. Using this technique, bright and sharp images of dislocations in crystalline silicon specimens as thick as 10 µm were obtained. A calibration curve to determine foil thickness of such a thick specimen was also derived. This method simply extends the observable thickness range in TEM. If combined with tilt series of observation over a significant range of angle, it will disclose three dimensional nanostructures in a µm-order block of a specimen, promoting our understanding of the controlling mechanisms behind various bulky material properties. - Highlights: • We developed a method which enables thick specimens to be observed using EF-TEM. • The effects of energy filter width and position on images were determined. • We suggested a method to determine the thickness of a thick film sample. • We achieved observation of microstructures in specimens with a thickness of 10 µm.

  13. A high-quality narrow passband filter for elastic SV waves via aligned parallel separated thin polymethylmethacrylate plates

    Directory of Open Access Journals (Sweden)

    Jun Zhang

    2017-08-01

    Full Text Available We designed a high-quality filter that consists of aligned parallel polymethylmethacrylate (PMMA thin plates with small gaps for elastic SV waves propagate in metals. Both the theoretical model and the full numerical simulation show the transmission spectrum of the elastic SV waves through such a filter has several sharp peaks with flawless transmission within the investigated frequencies. These peaks can be readily tuned by manipulating the geometry parameters of the PMMA plates. Our investigation finds that the same filter performs well for different metals where the elastic SV waves propagated.

  14. Nonlinear filtering for character recognition in low quality document images

    Science.gov (United States)

    Diaz-Escobar, Julia; Kober, Vitaly

    2014-09-01

    Optical character recognition in scanned printed documents is a well-studied task, where the captured conditions like sheet position, illumination, contrast and resolution are controlled. Nowadays, it is more practical to use mobile devices for document capture than a scanner. So as a consequence, the quality of document images is often poor owing to presence of geometric distortions, nonhomogeneous illumination, low resolution, etc. In this work we propose to use multiple adaptive nonlinear composite filters for detection and classification of characters. Computer simulation results obtained with the proposed system are presented and discussed.

  15. Accumulation of Elements in Salix and Other Species Used in Vegetation Filters with Focus on Wood Fuel Quality

    Energy Technology Data Exchange (ETDEWEB)

    Adler, Anneli

    2007-07-01

    Woody or herbaceous perennials used as vegetation filters for treatment of different types of wastes can be suitable for production of solid biofuels when their above ground harvestable biomass yield is sufficiently high and when biomass contains appropriate concentrations of minerals with regard to fuel combustion processes. The concentrations of nitrogen (N), potassium (K) and heavy metals (especially Zn and Cd) in fuel should be low and calcium (Ca) concentrations high to avoid technical problems and environmentally harmful emissions during combustion. Since soil supplementation with essential elements improves biomass yield, a conflict might arise between yield and quality aims. There are various possibilities to influence fuel quality during the growing phase of the life cycle of perennial biomass crops. This study assessed the suitability of two deciduous woody perennials (Salix and Populus) and two summer green herbaceous perennials (Phragmites and Urtica) for phytoremediation in terms of growth and nutrient allocation patterns. Salix and Populus proved suitable as vegetation filters when nutrients were available to plants in near-optimal proportions, but when unbalanced nutrient solutions (wastewater) were applied, stem biomass fraction was strongly reduced. Phragmites was more tolerant to wastewater treatment in terms of plant biomass production and nutrient allocation patterns, so if the N:P ratio of the wastewater is suboptimal, a vegetation filter using Phragmites could be considered. In further studies, a method was developed to determine the proportions of nutrient-rich bark in coppiced Salix, while heavy metal phytoextraction capacity was assessed in two Salix vegetation filters. The relevance of proportion of bark on wood fuel quality and element removal from vegetation filters was also investigated. The concentrations of the elements studied in harvestable Salix shoot biomass were higher, meaning lower wood fuel quality, in plantations where

  16. Improved Kalman Filter-Based Speech Enhancement with Perceptual Post-Filtering

    Institute of Scientific and Technical Information of China (English)

    WEIJianqiang; DULimin; YANZhaoli; ZENGHui

    2004-01-01

    In this paper, a Kalman filter-based speech enhancement algorithm with some improvements of previous work is presented. A new technique based on spectral subtraction is used for separation speech and noise characteristics from noisy speech and for the computation of speech and noise Autoregressive (AR) parameters. In order to obtain a Kalman filter output with high audible quality, a perceptual post-filter is placed at the output of the Kalman filter to smooth the enhanced speech spectra.Extensive experiments indicate that this newly proposed method works well.

  17. Predicting perceptual quality of images in realistic scenario using deep filter banks

    Science.gov (United States)

    Zhang, Weixia; Yan, Jia; Hu, Shiyong; Ma, Yang; Deng, Dexiang

    2018-03-01

    Classical image perceptual quality assessment models usually resort to natural scene statistic methods, which are based on an assumption that certain reliable statistical regularities hold on undistorted images and will be corrupted by introduced distortions. However, these models usually fail to accurately predict degradation severity of images in realistic scenarios since complex, multiple, and interactive authentic distortions usually appear on them. We propose a quality prediction model based on convolutional neural network. Quality-aware features extracted from filter banks of multiple convolutional layers are aggregated into the image representation. Furthermore, an easy-to-implement and effective feature selection strategy is used to further refine the image representation and finally a linear support vector regression model is trained to map image representation into images' subjective perceptual quality scores. The experimental results on benchmark databases present the effectiveness and generalizability of the proposed model.

  18. MISO Current-mode Biquad Filter with Independent Control of Pole Frequency and Quality Factor

    Directory of Open Access Journals (Sweden)

    W. Jaikla

    2012-09-01

    Full Text Available This article presents a three-inputs single-output biquadratic filter performing completely standard functions: low-pass, high-pass, band-pass, band-reject and all-pass functions, based on current controlled current conveyor transconductance amplifier (CCCCTA. The quality factor and pole frequency can be electronically/independently tuned via the input bias current. The proposed circuit uses 2 CCCCTAs and 2 grounded capacitors without external any resistors which is very suitable to further develop into an integrated circuit. The filter does not require double input current signal. Each function response can be selected by suitably selecting input signals with digital method. Moreover, the circuit possesses high output impedance which would be an ideal choice for current-mode cascading. The PSPICE simulation results are included to verify the workability of the proposed filter. The given results agree well with the theoretical anticipation.

  19. A comparison of filters for thoracic diagnosis

    International Nuclear Information System (INIS)

    Oestmann, J.W.; Hendrickx, P.; Rieder, P.; Geerlings, H.; Medizinische Hochschule Hannover

    1986-01-01

    The effect of three types of filter on the quality of radiographs of the chest was compared. These filters improve visualization of mediastinal structures without significantly reducing the quality of the pulmonary image. In practice the Du Pont filter proved best; the quality of the central and peripheral portions of the lung image is equal to that of an ordinary radiograph and visualization of the mediastinum is improved. The Agfa-Gevaert filter showed no significant disadvantages compared with the ordinary techniques but the improvement in mediastinal visualization is not that marked. The 3M-filter yields poor images of the central portions of the lung and its type of construction prevents the retrocardiac structures from being pictured as well as with the other filters. (orig.) [de

  20. Monte Carlo-based investigations on the impact of removing the flattening filter on beam quality specifiers for photon beam dosimetry.

    Science.gov (United States)

    Czarnecki, Damian; Poppe, Björn; Zink, Klemens

    2017-06-01

    The impact of removing the flattening filter in clinical electron accelerators on the relationship between dosimetric quantities such as beam quality specifiers and the mean photon and electron energies of the photon radiation field was investigated by Monte Carlo simulations. The purpose of this work was to determine the uncertainties when using the well-known beam quality specifiers or energy-based beam specifiers as predictors of dosimetric photon field properties when removing the flattening filter. Monte Carlo simulations applying eight different linear accelerator head models with and without flattening filter were performed in order to generate realistic radiation sources and calculate field properties such as restricted mass collision stopping power ratios (L¯/ρ)airwater, mean photon and secondary electron energies. To study the impact of removing the flattening filter on the beam quality correction factors k Q , this factor for detailed ionization chamber models was calculated by Monte Carlo simulations. Stopping power ratios (L¯/ρ)airwater and k Q values for different ionization chambers as a function of TPR1020 and %dd(10) x were calculated. Moreover, mean photon energies in air and at the point of measurement in water as well as mean secondary electron energies at the point of measurement were calculated. The results revealed that removing the flattening filter led to a change within 0.3% in the relationship between %dd(10) x and (L¯/ρ)airwater, whereby the relationship between TPR1020 and (L¯/ρ)airwater changed up to 0.8% for high energy photon beams. However, TPR1020 was a good predictor of (L¯/ρ)airwater for both types of linear accelerator with energies filter within 1.1% and 1.6% was observed for TPR1020 and %dd(10) x respectively. The results of this study have shown that removing the flattening filter led to a change in the relationship between the well-known beam quality specifiers and dosimetric quantities at the point of measurement

  1. Evaluation of MIT-SCAN-T2 for thickness quality control for PCC and HMA pavements : research project capsule.

    Science.gov (United States)

    2013-04-01

    Thickness is currently a pay item for portland cement concrete (PCC) pavements : and a quality control item for both PCC and hot mix asphalt (HMA) pavements. : A change in pavement thickness of 0.5 in. can result in a reduction of multiple : years of...

  2. On film quality in barium-air double contrast colon study

    International Nuclear Information System (INIS)

    Rhu, Sang Hyung; Rhee, Jae Ho; Kim, Hai Sung; Cheung, Hwan

    1984-01-01

    The colon double contrast study provides valuable diagnostic information by means of appropriate control of Kvp and mAa when making double contrast image by injecting air into the colon after coating the colon wall by appropriately diluted Barium solution. The following experiments were performed the results of which allowed to improve the quality of film in barium-air double contrast colon study: (1) Do the pictures have uniform density when measured with a densitometer from three measuring points established in the picture by changing Kvp and mAs depending on the thickness of the patient? (2) Is the quality of the picture improved by being compensated from the adjacent area when using a wedge filter in routine check lateral decubitus and erect view? (3) What is the optimum dilution of barium solution which gives the best result for colon wall coating? The above experiments revealed that as the patient's thickness increased, it should be considered to increase mAs as well as Kvp and a wedge filter could give diagnostically very informative pictures in routine-check lateral decubitus and erect view. And 70-80% solution of Barium-water mixture provided the best quality of double contrast image

  3. Underground coal mine air quality in mines using disposable diesel exhaust filter control devices

    Energy Technology Data Exchange (ETDEWEB)

    Carlson, D.H.; Johnson, J.H.; Bagley, S.T.; Gratz, L.D. [Michigan Technological University, Houghton, MI (United States). Dept. of Mining Engineering

    1996-07-01

    As part of a collaborative study with the US Bureau of Mines, in-mine studies have been conducted to assess the effects of a low temperature disposable diesel exhaust filter. The mines have been designed as mines R and S in US Bureau of Mines publications. Each mine operated three to four Jeffrey 4110 ramcar haulage vehicles in the test section. The ramcars were equipped with MWM D916-6 diesel engines, rated at 74.6 kW (100 hp), and were operated for 3 days with the disposal diesel exhaust filter and 2 days without in both mines. Average diesel particulate matter control efficiencies, as measured by samplers located on the coal haulage vehicle, were 80% in mine R and 76% in mine S. Diesel particulate matter average control efficiencies, as measured in the diesel engine tailpipe, were 52% for mine R (for two ramcar vehicles) and 86% for mine S (for four ramcar vehicles). The air quality index control efficiencies, as measured by samplers located on the coal haulage vehicle were 48% in mine R and 51% in mine S. The exhaust quality index control efficiencies from tailpipe measurements were 45% for mine R and 63% for mine S. As measured by a high volume sampler in mine S, diesel particulate matter and associated organics and mutagenic activity were reduced approximately 50% with the use of the disposal diesel exhaust filter. Similar results were found with modified personal samplers in mine R. Little effect was found on relative removal of semivolatile organics. The disposal diesel exhaust filter resulted in about a 50% reduction in the most volatile polynuclear hydrocarbons; however, there appeared to be little effect on the less volatile polynuclear hydrocarbons. The disposable diesel exhaust filter appears to be very effective in reducing the levels of all the diesel exhaust particulate components, while having minor effects on the relative breakdown of the individual components of the particulate. 30 refs., 13 figs., 4 tabs.

  4. A high-quality narrow passband filter for elastic SV waves via aligned parallel separated thin polymethylmethacrylate plates

    OpenAIRE

    Jun Zhang; Yaolu Liu; Wensheng Yan; Ning Hu

    2017-01-01

    We designed a high-quality filter that consists of aligned parallel polymethylmethacrylate (PMMA) thin plates with small gaps for elastic SV waves propagate in metals. Both the theoretical model and the full numerical simulation show the transmission spectrum of the elastic SV waves through such a filter has several sharp peaks with flawless transmission within the investigated frequencies. These peaks can be readily tuned by manipulating the geometry parameters of the PMMA plates. Our invest...

  5. An examination of mass thickness measurements with X-ray sources

    International Nuclear Information System (INIS)

    Chen Mincong; Li Hongmei; Chen Ziyu; Shen Ji

    2008-01-01

    A method using X-rays to measure mass thickness is discussed. The method utilizes a filter to absorb low energy and characteristic photons so that the hardened X-ray spectra have a peaked energy distribution. An equivalent X-ray energy, which defines the attenuation in a material of interest can be used. The effect on the X-ray spectra of different filters is examined with Monte Carlo simulation using the EGSnrc package. A theoretical model for X-ray absorption that shows that the method can achieve good precision for a certain range of mass thicknesses is advanced. Experimental results agree well with the theoretical analysis. It is found that for a certain range of mass thicknesses, the relative error can be less than 1% for the aluminum alloy sample at the tube voltage of 30 or 45 kV

  6. An examination of mass thickness measurements with X-ray sources

    Energy Technology Data Exchange (ETDEWEB)

    Chen Mincong; Li Hongmei; Chen Ziyu [Department of Modern Physics, University of Science and Technology of China, Jin Zhai Road, Hefei 230026 (China); Shen Ji [Department of Modern Physics, University of Science and Technology of China, Jin Zhai Road, Hefei 230026 (China)], E-mail: shenji@ustc.edu.cn

    2008-10-15

    A method using X-rays to measure mass thickness is discussed. The method utilizes a filter to absorb low energy and characteristic photons so that the hardened X-ray spectra have a peaked energy distribution. An equivalent X-ray energy, which defines the attenuation in a material of interest can be used. The effect on the X-ray spectra of different filters is examined with Monte Carlo simulation using the EGSnrc package. A theoretical model for X-ray absorption that shows that the method can achieve good precision for a certain range of mass thicknesses is advanced. Experimental results agree well with the theoretical analysis. It is found that for a certain range of mass thicknesses, the relative error can be less than 1% for the aluminum alloy sample at the tube voltage of 30 or 45 kV.

  7. Development of regeneration technique for diesel particulate filter made of porous metal; Kinzoku takotai DPF no saisei gijutsu no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Yoro, K; Ban, S; Ooka, T; Saito, H; Oji, M; Nakajima, S; Okamoto, S [Sumitomo Electric Industries, Ltd., Osaka (Japan)

    1997-10-01

    We have developed the diesel particulate filter (DPF) in which porous metal is used for a filter because of its high thermal conductivity and a radiation heater is used for a regeneration device because of its uniform thermal distribution. In the case high trapping efficiency is required, filter thickness should be thick. The thicker filter has a disadvantage of difficulty in regeneration because of the thermal distribution in the direction of thickness. In order to improve regeneration efficiency, we designed the best filter-heater construction which achieves uniform thermal distribution by using computer simulation and we confirmed good regeneration efficiency in the experiment. 4 refs., 14 figs., 1 tab.

  8. Measuring plate thickness using spatial local wavenumber filtering

    International Nuclear Information System (INIS)

    Kang, To; Han, Soon Woo; Park, Jin Ho; Lee, Jeong Han; Park, Gyu Hae; Jeon, Jun Young

    2016-01-01

    Corrosion on the surface of a structure can generate cracks or cause walls to thin. This can lead to fracturing, which can eventually lead to fatalities and property loss. In an effort to prevent this, laser imaging technology has been used over the last ten years to detect thin-plate structure, or relatively thin piping. The most common laser imaging was used to develop a new technology for inspecting and imaging a desired area in order to scan various structures for thin-plate structure and thin piping. However, this method builds images by measuring waves reflected from defects, and subsequently has a considerable time delay of a few milliseconds at each scanning point. In addition, the complexity of the system is high, due to additional required components, such as laser-focusing parts. This paper proposes a laser imaging method with an increased scanning speed, based on excitation and the measurement of standing waves in structures. The wavenumber of standing waves changes at sections with a geometrical discontinuity, such as thickness. Therefore, it is possible to detect defects in a structure by generating standing waves with a single frequency and scanning the waves at each point by with the laser scanning system. The proposed technique is demonstrated on a wall-thinned plate with a linear thickness variation

  9. Image Quality and Radiation Dose Assessment of a Digital Mammography System

    International Nuclear Information System (INIS)

    Isa, N. M.; Hassan, W. M. S. W.; Abdullah, W. A. K. W.; Othman, F.; Ramli, A. A. M.

    2010-01-01

    Image quality and radiation dose of a direct amorphous selenium digital mammography system were considered in terms of contrast to noise ratio (CNR) and average glandular dose (AGD). They were measured for various qualities and breast phantom thicknesses with different types of breast tissue composition to determine optimal radiation quality and dose. Three sets of breast tissue equivalent slabs (30%:70%, 50%:50% and 70%:30% glandular-adipose) with thickness of 2 cm to 7 cm and 0.2 mm aluminum foil were used to provide certain CNR. Two different combinations of anode/ilter material and a wide range of tube voltages were employed for each phantom thickness. Phantom images with grid were acquired using automatic exposure control (AEC) mode for each thickness. Phantom images without grid were also obtained in manual exposure mode by selecting the same anode/filter combination and kVp as the image obtained with grid at the same thickness, but varying mAs of 10 to 200 mAs. Optimization indicated that relatively high energy beam qualities should be used with a greater dose to compensate for lower energy x-rays. The results also indicate that current AEC setting for a fixed detector is not optimal.

  10. Soft x-ray transmission measurements on thin films used for XMM CCD-filters

    Science.gov (United States)

    Stephan, K.-H.; Reppin, C.; Maier, H. J.; Frischke, D.; Fuchs, D.; Müller, P.

    1997-02-01

    We have been developing optical filters for ESA's X-ray astronomy project XMM (X-ray Multi Mirror Mission). Specific CCDs will be used as detectors in the focal plane on board the observatory (1). Since these detectors are sensitive from the X-ray to the near infrared spectral range, X-ray observations require optical filters, which combine a high transparency for photon energies in the soft X-ray region and a high opacity for ultraviolet and visible radiation as well. With respect to the mission goal in orbit three types of flight model filters are designed having different spectral transmittance functions. We report on one of these types, a so-called "thick" filter, which has been realized within the EQM (Electrical Qualification Model)-phase of the project. The filter features a cut-off in the extreme ultraviolet spectral range and suppresses radiation below ˜10 eV photon energy by more than 8 orders of magnitude. It has an effective aperture of 73 mm without any support structure. A 0.35 μm thick polypropylene carrier foil is coated with metallic films of Al and Sn. We describe transmission measurements in the soft X-ray photon energy range to determine the thickness of the individual layers and present the optical performance data of the filter.

  11. Pilot production of the wedge filter for the TBI (total body irradiation)

    International Nuclear Information System (INIS)

    Ikezaki, Hiromi; Ikeda, Ikuo; Maruyama, Yasushi; Nako, Yasunobu; Tonari, Ayako; Kusuda, Junko; Takayama, Makoto

    2007-01-01

    Total body irradiation (TBI) is performed by various methods, such as a long SSD method and a translational couch method. For patient safety in carrying out TBI, the patient should be placed on the supine position and prone position near the floor. TBI is performed from 2 opposite ports (AP/PA) with a linear accelerator (10 MV X-ray). We experimented with a wedge filter for TBI created by us, which makes dose distribution to a floor uniform. The wedge filter, made of iron alloy, was attached to the linear accelerator. In designing the wedge filter, thickness of the lead-made wedge filter can be calculated numerically from the ratio of linear attenuation coefficient of iron alloy and lead. In measuring the dose profile for a phantom of 20 cm thick, dose homogeneity less than 10% was proved by the wedge filter for TBI. (author)

  12. Combination of Wiener filtering and singular value decomposition filtering for volume imaging PET

    International Nuclear Information System (INIS)

    Shao, L.; Lewitt, R.M.; Karp, J.S.

    1995-01-01

    Although the three-dimensional (3D) multi-slice rebinning (MSRB) algorithm in PET is fast and practical, and provides an accurate reconstruction, the MSRB image, in general, suffers from the noise amplified by its singular value decomposition (SVD) filtering operation in the axial direction. Their aim in this study is to combine the use of the Wiener filter (WF) with the SVD to decrease the noise and improve the image quality. The SVD filtering ''deconvolves'' the spatially variant axial response function while the WF suppresses the noise and reduces the blurring not modeled by the axial SVD filter but included in the system modulation transfer function. Therefore, the synthesis of these two techniques combines the advantages of both filters. The authors applied this approach to the volume imaging HEAD PENN-PET brain scanner with an axial extent of 256 mm. This combined filter was evaluated in terms of spatial resolution, image contrast, and signal-to-noise ratio with several phantoms, such as a cold sphere phantom and 3D brain phantom. Specifically, the authors studied both the SVD filter with an axial Wiener filter and the SVD filter with a 3D Wiener filter, and compared the filtered images to those from the 3D reprojection (3DRP) reconstruction algorithm. Their results indicate that the Wiener filter increases the signal-to-noise ratio and also improves the contrast. For the MSRB images of the 3D brain phantom, after 3D WF, both the Gray/White and Gray/Ventricle ratios were improved from 1.8 to 2.8 and 2.1 to 4.1, respectively. In addition, the image quality with the MSRB algorithm is close to that of the 3DRP algorithm with 3D WF applied to both image reconstructions

  13. Fabrication of a Cryogenic Bias Filter for Ultrasensitive Focal Plane

    Science.gov (United States)

    Chervenak, James; Wollack, Edward

    2012-01-01

    A fabrication process has been developed for cryogenic in-line filtering for the bias and readout of ultrasensitive cryogenic bolometers for millimeter and submillimeter wavelengths. The design is a microstripline filter that cuts out, or strongly attenuates, frequencies (10 50 GHz) that can be carried by wiring staged at cryogenic temperatures. The filter must have 100-percent transmission at DC and low frequencies where the bias and readout lines will carry signal. The fabrication requires the encapsulation of superconducting wiring in a dielectric-metal envelope with precise electrical characteristics. Sufficiently thick insulation layers with high-conductivity metal layers fully surrounding a patterned superconducting wire in arrayable formats have been demonstrated. A degenerately doped silicon wafer has been chosen to provide a metallic ground plane. A metallic seed layer is patterned to enable attachment to the ground plane. Thick silicon dioxide films are deposited at low temperatures to provide tunable dielectric isolation without degrading the metallic seed layer. Superconducting wiring is deposited and patterned using microstripline filtering techniques to cut out the relevant frequencies. A low Tc superconductor is used so that it will attenuate power strongly above the gap frequency. Thick dielectric is deposited on top of the circuit, and then vias are patterned through both dielectric layers. A thick conductive film is deposited conformally over the entire circuit, except for the contact pads for the signal and bias attachments to complete the encapsulating ground plane. Filters are high-aspect- ratio rectangles, allowing close packing in one direction, while enabling the chip to feed through the wall of a copper enclosure. The chip is secured in the copper wall using a soft metal seal to make good thermal and electrical contact to the outer shield.

  14. Static bending deflection and free vibration analysis of moderate thick symmetric laminated plates using multidimensional wave digital filters

    Science.gov (United States)

    Tseng, Chien-Hsun

    2018-06-01

    This paper aims to develop a multidimensional wave digital filtering network for predicting static and dynamic behaviors of composite laminate based on the FSDT. The resultant network is, thus, an integrated platform that can perform not only the free vibration but also the bending deflection of moderate thick symmetric laminated plates with low plate side-to-thickness ratios (< = 20). Safeguarded by the Courant-Friedrichs-Levy stability condition with the least restriction in terms of optimization technique, the present method offers numerically high accuracy, stability and efficiency to proceed a wide range of modulus ratios for the FSDT laminated plates. Instead of using a constant shear correction factor (SCF) with a limited numerical accuracy for the bending deflection, an optimum SCF is particularly sought by looking for a minimum ratio of change in the transverse shear energy. This way, it can predict as good results in terms of accuracy for certain cases of bending deflection. Extensive simulation results carried out for the prediction of maximum bending deflection have demonstratively proven that the present method outperforms those based on the higher-order shear deformation and layerwise plate theories. To the best of our knowledge, this is the first work that shows an optimal selection of SCF can significantly increase the accuracy of FSDT-based laminates especially compared to the higher order theory disclaiming any correction. The highest accuracy of overall solution is compared to the 3D elasticity equilibrium one.

  15. Filters in nuclear facilities

    International Nuclear Information System (INIS)

    Berg, K.H.; Wilhelm, J.G.

    1985-01-01

    The topics of the nine papers given include the behavior of HEPA filters during exposure to air flows of high humidity as well as of high differential pressure, the development of steel-fiber filters suitable for extreme operating conditions, and the occurrence of various radioactive iodine species in the exhaust air from boiling water reactors. In an introductory presentation the German view of the performance requirements to be met by filters in nuclear facilities as well as the present status of filter quality assurance are discussed. (orig.) [de

  16. Performance tuning for CUDA-accelerated neighborhood denoising filters

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Ziyi; Mueller, Klaus [Stony Brook Univ., NY (United States). Center for Visual Computing, Computer Science; Xu, Wei

    2011-07-01

    Neighborhood denoising filters are powerful techniques in image processing and can effectively enhance the image quality in CT reconstructions. In this study, by taking the bilateral filter and the non-local mean filter as two examples, we discuss their implementations and perform fine-tuning on the targeted GPU architecture. Experimental results show that the straightforward GPU-based neighborhood filters can be further accelerated by pre-fetching. The optimized GPU-accelerated denoising filters are ready for plug-in into reconstruction framework to enable fast denoising without compromising image quality. (orig.)

  17. Effects of fixture rotation on coating uniformity for high-performance optical filter fabrication

    Science.gov (United States)

    Rubin, Binyamin; George, Jason; Singhal, Riju

    2018-04-01

    Coating uniformity is critical in fabricating high-performance optical filters by various vacuum deposition methods. Simple and planetary rotation systems with shadow masks are used to achieve the required uniformity [J. B. Oliver and D. Talbot, Appl. Optics 45, 13, 3097 (2006); O. Lyngnes, K. Kraus, A. Ode and T. Erguder, in `Method for Designing Coating Thickness Uniformity Shadow Masks for Deposition Systems with a Planetary Fixture', 2014 Technical Conference Proceedings, Optical Coatings, August 13, 2014, DOI: 10.14332/svc14.proc.1817.]. In this work, we discuss the effect of rotation pattern and speed on thickness uniformity in an ion beam sputter deposition system. Numerical modeling is used to determine statistical distribution of random thickness errors in coating layers. The relationship between thickness tolerance and production yield are simulated theoretically and demonstrated experimentally. Production yields for different optical filters produced in an ion beam deposition system with planetary rotation are presented. Single-wavelength and broadband optical monitoring systems were used for endpoint monitoring during filter deposition. Limitations of thickness tolerances that can be achieved in systems with planetary rotation are shown. Paths for improving production yield in an ion beam deposition system are described.

  18. Two-dimensional filtering of SPECT images using the Metz and Wiener filters

    International Nuclear Information System (INIS)

    King, M.A.; Schwinger, R.B.; Penney, B.C.; Doherty, P.W.

    1984-01-01

    Presently, single photon emission computed tomographic (SPECT) images are usually reconstructed by arbitrarily selecting a one-dimensional ''window'' function for use in reconstruction. A better method would be to automatically choose among a family of two-dimensional image restoration filters in such a way as to produce ''optimum'' image quality. Two-dimensional image processing techniques offer the advantages of a larger statistical sampling of the data for better noise reduction, and two-dimensional image deconvolution to correct for blurring during acquisition. An investigation of two such ''optimal'' digital image restoration techniques (the count-dependent Metz filter and the Wiener filter) was made. They were applied both as two-dimensional ''window'' functions for preprocessing SPECT images, and for filtering reconstructed images. Their performance was compared by measuring image contrast and per cent fractional standard deviation (% FSD) in multiple-acquisitions of the Jaszczak SPECT phantom at two different count levels. A statistically significant increase in image contrast and decrease in % FSD was observed with these techniques when compared to the results of reconstruction with a ramp filter. The adaptability of the techniques was manifested in a lesser % reduction in % FSD at the high count level coupled with a greater enhancement in image contrast. Using an array processor, processing time was 0.2 sec per image for the Metz filter and 3 sec for the Wiener filter. It is concluded that two-dimensional digital image restoration with these techniques can produce a significant increase in SPECT image quality

  19. A tunable Fabry-Perot filter (λ/18) based on all-dielectric metamaterials

    Science.gov (United States)

    Ao, Tianhong; Xu, Xiangdong; Gu, Yu; Jiang, Yadong; Li, Xinrong; Lian, Yuxiang; Wang, Fu

    2018-05-01

    A tunable Fabry-Perot filter composed of two separated all-dielectric metamaterials is proposed and numerically investigated. Different from metallic metamaterials reflectors, the all-dielectric metamaterials are constructed by high-permittivity TiO2 cylinder arrays and exhibit high reflection in a broadband of 2.49-3.08 THz. The high reflection is attributed to the first and second Mie resonances, by which the all-dielectric metamaterials can serve as reflectors in the Fabry-Perot filter. Both the results from phase analysis method and CST simulations reveal that the resonant frequency of the as-proposed filter appears at 2.78 THz, responding to a cavity with λ/18 wavelength thickness. Particularly, the resonant frequency can be adjusted by changing the cavity thickness. This work provides a feasible approach to design low-loss terahertz filters with a thin air cavity.

  20. Impact of a silver layer on the membrane of tap water filters on the microbiological quality of filtered water

    Directory of Open Access Journals (Sweden)

    Bruderek Juliane

    2008-10-01

    Full Text Available Abstract Background Bacteria in the hospital's drinking water system represent a risk for the acquisition of a nosocomial infection in the severely immunocompromised host. Terminal tap water filters may be used to prevent nosocomial Legionnaires' disease. We present data from water samples using an improved kind of tap water filters. Methods In a blinded study on an intermediate care unit of the thoracic surgery department, a modified type of the Germlyser water filter (Aqua-Free Membrane Technology with a newly-introduced silver layer on the filtration membrane was compared to its preceding type without such a layer on 15 water outlets. We determined growth of Legionella, other pathogenic bacteria, and the total heterotrophic plate count in unfiltered water and filtered water samples after filter usage intervals of 1 through 4 weeks. Results A total of 299 water samples were tested. Twenty-nine of the 60 unfiltered water samples contained Legionella of various serogroups (baseline value. In contrast, all samples filtered by the original water filter and all but one of the water samples filtered by the modified filter type remained Legionella-free. No other pathogenic bacteria were detected in any filtered sample. The total plate count in water samples increased during use of both kinds of filters over time. However, for the first 7 days of use, there were significantly fewer water samples containing >100 CFU per mL when using the new filter device compared with the older filters or taps with no filter. No advantage was seen thereafter. Conclusion The use of this type of terminal water filter is an appropriate method to protect immunocompromised patients from water-borne pathogens such as Legionella.

  1. Visible Wavelength Color Filters Using Dielectric Subwavelength Gratings for Backside-Illuminated CMOS Image Sensor Technologies.

    Science.gov (United States)

    Horie, Yu; Han, Seunghoon; Lee, Jeong-Yub; Kim, Jaekwan; Kim, Yongsung; Arbabi, Amir; Shin, Changgyun; Shi, Lilong; Arbabi, Ehsan; Kamali, Seyedeh Mahsa; Lee, Hong-Seok; Hwang, Sungwoo; Faraon, Andrei

    2017-05-10

    We report transmissive color filters based on subwavelength dielectric gratings that can replace conventional dye-based color filters used in backside-illuminated CMOS image sensor (BSI CIS) technologies. The filters are patterned in an 80 nm-thick poly silicon film on a 115 nm-thick SiO 2 spacer layer. They are optimized for operating at the primary RGB colors, exhibit peak transmittance of 60-80%, and have an almost insensitive response over a ± 20° angular range. This technology enables shrinking of the pixel sizes down to near a micrometer.

  2. Pyrolytic Graphite as a Tunable Second order Neutron Filter

    International Nuclear Information System (INIS)

    Adib, M.

    2009-01-01

    A study has been carried out on the neutron transmission through pyrolytic graphite (PG) crystals in order to check its applicability as an efficient tunable second order neutron filter. The neutron transmission have been calculated as a function of neutron wavelengths in the range from 0.01 nm up to 0.7 nm at various PG mosaic spread, thickness and orientation of its c-axis with respect to the beam direction The Computer package Graphite has been used to provide the required calculation. It was shown that highly aligned (10 FWHM on mosaic spread) PG crystal ∼2 cm thick, may be tuned for optimum scattering of 2 second order neutrons within some favorable wavelength intervals in the range between 0.112 and 0.425 nm by adjusting the crystal in an appropriate orientation. .However, a less quality and thinner PG was found to almost eliminate 2 second order neutrons at only tuned values of wavelength corresponding to the poison of the triple intersection points of the curves (hkl) ± and (00l)

  3. Polarization-Insensitive Tunable Optical Filters based on Liquid Crystal Polarization Gratings

    Science.gov (United States)

    Nicolescu, Elena

    Tunable optical filters are widely used for a variety of applications including spectroscopy, optical communication networks, remote sensing, and biomedical imaging and diagnostics. All of these application areas can greatly benefit from improvements in the key characteristics of the tunable optical filters embedded in them. Some of these key parameters include peak transmittance, bandwidth, tuning range, and transition width. In recent years research efforts have also focused on miniaturizing tunable optical filters into physically small packages for compact portable spectroscopy and hyperspectral imaging applications such as real-time medical diagnostics and defense applications. However, it is important that miniaturization not have a detrimental effect on filter performance. The overarching theme of this dissertation is to explore novel configurations of Polarization Gratings (PGs) as simple, low-cost, polarization-insensitive alternatives to conventional optical filtering technologies for applications including hyperspectral imaging and telecommunications. We approach this goal from several directions with a combination of theory and experimental demonstration leading to, in our opinion, a significant contribution to the field. We present three classes of tunable optical filters, the first of which is an angle-filtering scheme where the stop-band wavelengths are redirected off axis and the passband is transmitted on-axis. This is achieved using a stacked configuration of polarization gratings of various thicknesses. To improve this class of filter, we also introduce a novel optical element, the Bilayer Polarization Grating, exhibiting unique optical properties and demonstrating complex anchoring conditions with high quality. The second class of optical filter is analogous to a Lyot filter, utilizing stacks of static or tunable waveplates sandwiched with polarizing elements. However, we introduce a new configuration using PGs and static waveplates to replace

  4. WE-F-16A-02: Design, Fabrication, and Validation of a 3D-Printed Proton Filter for Range Spreading

    International Nuclear Information System (INIS)

    Remmes, N; Courneyea, L; Corner, S; Beltran, C; Kemp, B; Kruse, J; Herman, M; Stoker, J

    2014-01-01

    Purpose: To design, fabricate and test a 3D-printed filter for proton range spreading in scanned proton beams. The narrow Bragg peak in lower-energy synchrotron-based scanned proton beams can result in longer treatment times for shallow targets due to energy switching time and plan quality degradation due to minimum monitor unit limitations. A filter with variable thicknesses patterned on the same scale as the beam's lateral spot size will widen the Bragg peak. Methods: The filter consists of pyramids dimensioned to have a Gaussian distribution in thickness. The pyramids are 2.5mm wide at the base, 0.6 mm wide at the peak, 5mm tall, and are repeated in a 2.5mm pseudo-hexagonal lattice. Monte Carlo simulations of the filter in a proton beam were run using TOPAS to assess the change in depth profiles and lateral beam profiles. The prototypes were constrained to a 2.5cm diameter disk to allow for micro-CT imaging of promising prototypes. Three different 3D printers were tested. Depth-doses with and without the prototype filter were then measured in a ~70MeV proton beam using a multilayer ion chamber. Results: The simulation results were consistent with design expectations. Prototypes printed on one printer were clearly unacceptable on visual inspection. Prototypes on a second printer looked acceptable, but the micro-CT image showed unacceptable voids within the pyramids. Prototypes from the third printer appeared acceptable visually and on micro-CT imaging. Depth dose scans using the prototype from the third printer were consistent with simulation results. Bragg peak width increased by about 3x. Conclusions: A prototype 3D printer pyramid filter for range spreading was successfully designed, fabricated and tested. The filter has greater design flexibility and lower prototyping and production costs compared to traditional ridge filters. Printer and material selection played a large role in the successful development of the filter

  5. WE-F-16A-02: Design, Fabrication, and Validation of a 3D-Printed Proton Filter for Range Spreading

    Energy Technology Data Exchange (ETDEWEB)

    Remmes, N; Courneyea, L; Corner, S; Beltran, C; Kemp, B; Kruse, J; Herman, M [Mayo Clinic, Rochester, MN (United States); Stoker, J [MD Anderson Cancer Center, Houston, TX (United States)

    2014-06-15

    Purpose: To design, fabricate and test a 3D-printed filter for proton range spreading in scanned proton beams. The narrow Bragg peak in lower-energy synchrotron-based scanned proton beams can result in longer treatment times for shallow targets due to energy switching time and plan quality degradation due to minimum monitor unit limitations. A filter with variable thicknesses patterned on the same scale as the beam's lateral spot size will widen the Bragg peak. Methods: The filter consists of pyramids dimensioned to have a Gaussian distribution in thickness. The pyramids are 2.5mm wide at the base, 0.6 mm wide at the peak, 5mm tall, and are repeated in a 2.5mm pseudo-hexagonal lattice. Monte Carlo simulations of the filter in a proton beam were run using TOPAS to assess the change in depth profiles and lateral beam profiles. The prototypes were constrained to a 2.5cm diameter disk to allow for micro-CT imaging of promising prototypes. Three different 3D printers were tested. Depth-doses with and without the prototype filter were then measured in a ~70MeV proton beam using a multilayer ion chamber. Results: The simulation results were consistent with design expectations. Prototypes printed on one printer were clearly unacceptable on visual inspection. Prototypes on a second printer looked acceptable, but the micro-CT image showed unacceptable voids within the pyramids. Prototypes from the third printer appeared acceptable visually and on micro-CT imaging. Depth dose scans using the prototype from the third printer were consistent with simulation results. Bragg peak width increased by about 3x. Conclusions: A prototype 3D printer pyramid filter for range spreading was successfully designed, fabricated and tested. The filter has greater design flexibility and lower prototyping and production costs compared to traditional ridge filters. Printer and material selection played a large role in the successful development of the filter.

  6. Amelioration of Electrical Power Quality based on Modulated Power Filter Compensator

    Directory of Open Access Journals (Sweden)

    Karrar Hameed Kadhim

    2017-08-01

    Full Text Available This paper deals with the performance of modeling and implementation of Modulated Power Filter Compensator ( MPFC based on synchronous generator to enhance Electrical Power Quality (EPQ performance , rectification power factor , voltage fixity and decreasing transmission line losses for 300 km transmission line . In this paper (MPFC sketch attendants for intelligent network stability and optimum exploitation. The proposal Flexible AC Transmission Systems ( FACTS can be expanded to distributed renewable energy interface and exploitation systems and also will be easy to modify for voltage fixity, Achieve the required stability, perfect usage and Compensation requirements. MATLAB SIMLINK version R2009b were used as a model of (MPFC.

  7. Improving Filtered Backprojection Reconstruction by Data-Dependent Filtering

    NARCIS (Netherlands)

    D.M. Pelt (Daniël); K.J. Batenburg (Joost)

    2014-01-01

    htmlabstractFiltered backprojection, one of the most widely used reconstruction methods in tomography, requires a large number of low-noise projections to yield accurate reconstructions. In many applications of tomography, complete projection data of high quality cannot be obtained, because of

  8. An optimal filter for short photoplethysmogram signals

    Science.gov (United States)

    Liang, Yongbo; Elgendi, Mohamed; Chen, Zhencheng; Ward, Rabab

    2018-01-01

    A photoplethysmogram (PPG) contains a wealth of cardiovascular system information, and with the development of wearable technology, it has become the basic technique for evaluating cardiovascular health and detecting diseases. However, due to the varying environments in which wearable devices are used and, consequently, their varying susceptibility to noise interference, effective processing of PPG signals is challenging. Thus, the aim of this study was to determine the optimal filter and filter order to be used for PPG signal processing to make the systolic and diastolic waves more salient in the filtered PPG signal using the skewness quality index. Nine types of filters with 10 different orders were used to filter 219 (2.1s) short PPG signals. The signals were divided into three categories by PPG experts according to their noise levels: excellent, acceptable, or unfit. Results show that the Chebyshev II filter can improve the PPG signal quality more effectively than other types of filters and that the optimal order for the Chebyshev II filter is the 4th order. PMID:29714722

  9. Mini-pleat filters for improved indoor air quality. Filtri a 'piccole pieghe' per una migliore qualita' dell'aria negli ambienti civili e negli impianti industriali

    Energy Technology Data Exchange (ETDEWEB)

    Zucchelli, D.

    1992-07-01

    Advanced manufacturing techniques applied to the fabrication of air filters have led to the creation of a high quality/efficiency mini-pleat filter which, however, has yet to see wide use in commercial space heating ventilation and air conditioning systems. Now, with greater attention being given to indoor air quality, these high performance filters should see greater market demand. This paper discusses the design and performance characteristics of mini-pleat filters and surveys the range of models currently available on the market.

  10. Evaluation of data from HEPA filter quality assurance testing stations

    International Nuclear Information System (INIS)

    Collins, J.T.; Bellamy, R.R.; Allen, J.R.

    1979-01-01

    In Revision 1 to Regulatory Guide 1.52, issued in July 1976, the NRC recommended that high efficiency particulate air (HEPA) filters for use in engineered safety features (ESF) atmosphere cleanup systems be visually inspected and dioctylphtalate (DOP) tested at either of two Department of Energy (DOE) operated QA Filter Testing Stations prior to their installation and use in commercial nuclear power plants. This practice was initiated because filter vendors were unable to consistently provide a HEPA filter that would meet the stringent requirements established by DOE and NRC and its predecessor the AEC. In 1977, the NRC staff undertook a program to revise Regulatory Guide 1.52 to reflect recently issued industry standards (e.g., ANSI N509 and N510) and current industry practices. Revision 2 to Regulatory Guide 1.52 was formally issued in March 1978. In conducting this review, the recommendation that HEPA filters, intended for use in ESF systems in commercial nuclear power plants, be routinely tested at the DOE-QA Filter Testing Stations was revaluated. As part of this evluation a detailed analysis of the filter test results recorded by the two QA Testing Stations during the period 1971 to 1977 was conducted. This paper summarizes the results of the analysis and explains the rationale for deleting the requirement that all HEPA filters intended for use in ESF systems be tested at the AQ Testing Station

  11. Filtered epithermal quasi-monoenergetic neutron beams at research reactor facilities.

    Science.gov (United States)

    Mansy, M S; Bashter, I I; El-Mesiry, M S; Habib, N; Adib, M

    2015-03-01

    Filtered neutron techniques were applied to produce quasi-monoenergetic neutron beams in the energy range of 1.5-133keV at research reactors. A simulation study was performed to characterize the filter components and transmitted beam lines. The filtered beams were characterized in terms of the optimal thickness of the main and additive components. The filtered neutron beams had high purity and intensity, with low contamination from the accompanying thermal emission, fast neutrons and γ-rays. A computer code named "QMNB" was developed in the "MATLAB" programming language to perform the required calculations. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Novel trimming technique for tunable HTS microstrip filters

    Energy Technology Data Exchange (ETDEWEB)

    Sekiya, N. [Department of Electrical Engineering, Yamanashi University, Nakagawa-Sekiya Laboratory, 4-3-11 Takeda, Kofu 400-8511 (Japan)], E-mail: nsekiya@yamanashi.ac.jp; Nakagawa, Y. [Department of Electrical Engineering, Yamanashi University, Nakagawa-Sekiya Laboratory, 4-3-11 Takeda, Kofu 400-8511 (Japan); Saito, A.; Ohshima, S. [Yamagata University, 4-3-16 Johnan, Yonezawa 992-8510 (Japan)

    2008-09-15

    We have developed a method using additional electric pads for trimming tunable high-temperature superconducting (HTS) microstrip filters. These filters are generally tuned by adjusting the gap between a dielectric floating plate above the filter. When the floating plate approached the filter, the center frequency was shifted to a lower frequency. However, the insertion loss increases due to variation in the external quality factors varying from the design parameter. The external quality factors are usually controlled by adjusting the length of the input/output (I/O) coupled-line elements and the gap between the elements and the resonator. In our method, additional electric pads are distributed at the open-end of the I/O coupled-line elements of a 3-pole hairpin bandpass filter to enable adjustment of the external quality factors so as to reduce insertion loss. The electric pads consist of line-and-space patterns. They are eclectically connected to the coupled-line elements to adjust the line length and gap width and thereby control the external quality factors. An electromagnetic simulator was used for the design and analysis. The simulation results showed that the additional electric pads are effective in improving the insertion loss of the HTS bandpass filter after tuning.

  13. Novel trimming technique for tunable HTS microstrip filters

    International Nuclear Information System (INIS)

    Sekiya, N.; Nakagawa, Y.; Saito, A.; Ohshima, S.

    2008-01-01

    We have developed a method using additional electric pads for trimming tunable high-temperature superconducting (HTS) microstrip filters. These filters are generally tuned by adjusting the gap between a dielectric floating plate above the filter. When the floating plate approached the filter, the center frequency was shifted to a lower frequency. However, the insertion loss increases due to variation in the external quality factors varying from the design parameter. The external quality factors are usually controlled by adjusting the length of the input/output (I/O) coupled-line elements and the gap between the elements and the resonator. In our method, additional electric pads are distributed at the open-end of the I/O coupled-line elements of a 3-pole hairpin bandpass filter to enable adjustment of the external quality factors so as to reduce insertion loss. The electric pads consist of line-and-space patterns. They are eclectically connected to the coupled-line elements to adjust the line length and gap width and thereby control the external quality factors. An electromagnetic simulator was used for the design and analysis. The simulation results showed that the additional electric pads are effective in improving the insertion loss of the HTS bandpass filter after tuning

  14. Ultrathin Epitaxial Ferromagneticγ-Fe2O3Layer as High Efficiency Spin Filtering Materials for Spintronics Device Based on Semiconductors

    KAUST Repository

    Li, Peng

    2016-06-01

    In spintronics, identifying an effective technique for generating spin-polarized current has fundamental importance. The spin-filtering effect across a ferromagnetic insulating layer originates from unequal tunneling barrier heights for spin-up and spin-down electrons, which has shown great promise for use in different ferromagnetic materials. However, the low spin-filtering efficiency in some materials can be ascribed partially to the difficulty in fabricating high-quality thin film with high Curie temperature and/or partially to the improper model used to extract the spin-filtering efficiency. In this work, a new technique is successfully developed to fabricate high quality, ferrimagnetic insulating γ-Fe2O3 films as spin filter. To extract the spin-filtering effect of γ-Fe2O3 films more accurately, a new model is proposed based on Fowler–Nordheim tunneling and Zeeman effect to obtain the spin polarization of the tunneling currents. Spin polarization of the tunneled current can be as high as −94.3% at 2 K in γ-Fe2O3 layer with 6.5 nm thick, and the spin polarization decays monotonically with temperature. Although the spin-filter effect is not very high at room temperature, this work demonstrates that spinel ferrites are very promising materials for spin injection into semiconductors at low temperature, which is important for development of novel spintronics devices. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim

  15. Gradient based filtering of digital elevation models

    DEFF Research Database (Denmark)

    Knudsen, Thomas; Andersen, Rune Carbuhn

    We present a filtering method for digital terrain models (DTMs). The method is based on mathematical morphological filtering within gradient (slope) defined domains. The intention with the filtering procedure is to improbé the cartographic quality of height contours generated from a DTM based...

  16. Gas permeability through thin-foil x-ray filters

    Science.gov (United States)

    Tveekrem, June L.; Keski-Kuha, Ritva A.; Webb, Andrew T.

    1997-10-01

    We have measured the permeation rates of helium and water through thin-foil UV-blocking filters used in the ASTRO-E/x- ray spectrometer (XRS) instrument. In the XRS program, there is a concern that outgassed contaminants such as water could permeate through the outermost filter which will be at room temperature and freeze on the inner filters which will be at cryogenic temperatures. The filters tested consisted of approximately 1000 angstroms Al on approximately 1000 angstroms of either Lexan or polyimide. Measurements were made using a vacuum apparatus consisting essentially of two small chambers separated by the filter under test. A helium leak detector was used to measure helium permeation rates, and a residual gas analyzer (RGA) was used to detect water. Results discussed include permeation rate as a function of pressure difference across a filter, the ratio of helium permeation rate over water permeation rate, and the effect of the aluminum layer thickness on permeation.

  17. Evaluation of treatment plan quality of IMRT and VMAT with and without flattening filter using Pareto optimal fronts.

    Science.gov (United States)

    Lechner, Wolfgang; Kragl, Gabriele; Georg, Dietmar

    2013-12-01

    To investigate the differences in treatment plan quality of IMRT and VMAT with and without flattening filter using Pareto optimal fronts, for two treatment sites of different anatomic complexity. Pareto optimal fronts (POFs) were generated for six prostate and head-and-neck cancer patients by stepwise reduction of the constraint (during the optimization process) of the primary organ-at-risk (OAR). 9-static field IMRT and 360°-single-arc VMAT plans with flattening filter (FF) and without flattening filter (FFF) were compared. The volume receiving 5 Gy or more (V5 Gy) was used to estimate the low dose exposure. Furthermore, the number of monitor units (MUs) and measurements of the delivery time (T) were used to assess the efficiency of the treatment plans. A significant increase in MUs was found when using FFF-beams while the treatment plan quality was at least equivalent to the FF-beams. T was decreased by 18% for prostate for IMRT with FFF-beams and by 4% for head-and-neck cases, but increased by 22% and 16% for VMAT. A reduction of up to 5% of V5 Gy was found for IMRT prostate cases with FFF-beams. The evaluation of the POFs showed an at least comparable treatment plan quality of FFF-beams compared to FF-beams for both treatment sites and modalities. For smaller targets the advantageous characteristics of FFF-beams could be better exploited. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  18. Thermal and structural behavior of filters and windows for synchrotron x-ray sources

    International Nuclear Information System (INIS)

    Wang, Z.; Hahn, U.; Dejus, R.; Kuzay, T.

    1993-01-01

    This report contains the following discussions: Introduction: Use of filters and windows in the front end designs; An interactive code for 3D graphic viewing of absorbed power in filters/windows and a new heat load generation algorithm for the finite element analysis; Failure criteria and analysis methods for the filter and window assembly; Comparison with test data and existing devices in HASYLAB; Cooling the filter: Radiation cooling or conduction cooling?; Consideration of window and filter thickness: Thicker or thinner?; Material selection criteria for filters/windows; Photon transmission through filters/windows; Window and filter design for APS undulators; Window and filter design for APS wigglers; and Window design for APS bending magnet front ends

  19. Experimental investigation of an optical water filter for Photovoltaic/Thermal conversion module

    International Nuclear Information System (INIS)

    Al-Shohani, Wisam A.M.; Sabouri, Aydin; Al-Dadah, Raya; Mahmoud, Saad; Butt, Haider

    2016-01-01

    Highlights: • New design of Photovoltaic/Thermal system is proposed. • Using the optical water layer as a spectrum splitter is tested experimentally. • Optical rig is developed to study the optical performance of water layer. • Energy conversion under different water layer thicknesses is determined. - Abstract: This paper presents an experimental investigation of a novel optical water filter used for Photovoltaic/Thermal and Concentrating Photovoltaic/Thermal modules. A water layer is used as a spectrum splitter of solar radiation placed above the photovoltaic cells and as a thermal working fluid simultaneously. The water layer absorbs the ultraviolet and part of infrared, which are not used by the photovoltaic, but transmits the visible and some of infrared to the solar cell surface which are used by the photovoltaic. In this work, the transmittance of the optical water filter was measured for different water thicknesses (1, 2, 3, 4, and 5 cm) and radiation wavelength ranging from 0.35 to 1 μm. Results show that there is a significant effect of the water layer thickness on the transmittance of the spectra where the transmittance decreases as the water layer increases. Moreover, energy conversion rate of photovoltaic with the optical water filter at different water layer thicknesses has been determined.

  20. Comparison of filters: Inkjet printed on PEN substrate versus a laser-etched on LCP substrate

    KAUST Repository

    Arabi, Eyad A.

    2014-10-01

    In this paper, microstrip-based bandpass filters on polyethylene naphthalate (PEN) and liquid crystal polymers (LCP) are presented to investigate the performance of filters on ultra-thin substrates. PEN (with a thickness of 120 μm) has been characterized and used for a filter for the first time. In addition to being low cost and transparent, it demonstrates comparable RF performance to LCP. The conductor losses are compared by fabricating filters with inkjet printed lines as well as laser etched copper clad LCP sheets. With 5 layers of inkjet printing, and a curing temperature below 200°C, a final silver thickness of 2 μm and conductivity of 9.6 × 106 S/m are achieved. The designs are investigated at two frequencies, 24 GHz as well as 5 GHz to assess their performance at high and low frequencies respectively. The 24 GHz inkjet printed filter shows an insertion loss of 2 dB, while the 5 GHz design gives an insertion loss of 8 dB. We find that thin substrates have a strong effect on the insertion loss of filters especially as the frequency is reduced. The same design, realized on LCP (thickness of 100 μm) through laser etching, demonstrates a very similar performance, thus verifying this finding. © 2014 European Microwave Association.

  1. Comparison of filters: Inkjet printed on PEN substrate versus a laser-etched on LCP substrate

    KAUST Repository

    Arabi, Eyad A.; McKerricher, Garret; Shamim, Atif

    2014-01-01

    In this paper, microstrip-based bandpass filters on polyethylene naphthalate (PEN) and liquid crystal polymers (LCP) are presented to investigate the performance of filters on ultra-thin substrates. PEN (with a thickness of 120 μm) has been characterized and used for a filter for the first time. In addition to being low cost and transparent, it demonstrates comparable RF performance to LCP. The conductor losses are compared by fabricating filters with inkjet printed lines as well as laser etched copper clad LCP sheets. With 5 layers of inkjet printing, and a curing temperature below 200°C, a final silver thickness of 2 μm and conductivity of 9.6 × 106 S/m are achieved. The designs are investigated at two frequencies, 24 GHz as well as 5 GHz to assess their performance at high and low frequencies respectively. The 24 GHz inkjet printed filter shows an insertion loss of 2 dB, while the 5 GHz design gives an insertion loss of 8 dB. We find that thin substrates have a strong effect on the insertion loss of filters especially as the frequency is reduced. The same design, realized on LCP (thickness of 100 μm) through laser etching, demonstrates a very similar performance, thus verifying this finding. © 2014 European Microwave Association.

  2. Filter system for purifying gas or air streams

    International Nuclear Information System (INIS)

    Ohlmeyer, M.; Wilhelm, J.

    1981-01-01

    A filter system is provided for purifying a gas stream by means of flowable or tricklable contact filter material, wherein the stream flows through the filter material and the filter material forms a movable bed. The system contains a filter chamber through which the filter material can flow and which is provided with an inlet opening and an outlet opening for the filter material between which the filter material is conveyed by gravity. The filter system includes deflection means for deflecting the stream , after a first passage of the stream through the filter bed to charge the filter bed for a first time, to a position above where the stream first passed through the filter bed and for conducting the stream at least once again transversely through the filter bed above the first charge so that the filter bed is charged a second time. The filter chamber contains a first opening where the stream enters the filter bed for the first time and is aligned with the deflection means, and a second opening aligned with the deflection means and above the first opening. The second opening is located where the stream leaves the filter bed for the second time, with a partial quantity of the gas stream being able to pass directly through the filter bed from the first opening to the second opening without going through the deflection means. The distance between the upper edge of the first opening and the lower edge of the second opening is at least twice the thickness of the filter chamber

  3. Multi-Material and Thickness Optimization Utilizing Casting Filters for Laminated Composite Structures

    DEFF Research Database (Denmark)

    Sørensen, Rene; Lund, Erik

    2013-01-01

    . The reformulation eliminates the need for having explicit constraint for ensuring that intermediate void does not appear in between layers of the laminate. This is achieved by utilizing a filtering technique known as a casting constraint from traditional topology optimization with isotropic materials....

  4. Dose profile measurement using an imaging plate: Evaluation of filters using Monte Carlo simulation of 4 MV x-rays

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, Masatoshi [Division of Radiology and Biomedical Engineering, Graduate School of Medicine, University of Tokyo, Bunkyo-ku, Tokyo 113-8655 (Japan); Department of Therapeutic Radiology, Medical Plaza Edogawa, Edogawa-ku, Tokyo 133-0052 (Japan); Tomita, Tetsuya; Sawada, Koichi [Department of Radiology, Chiba University Hospital, Cyuo-ku, Chiba 260-8677 (Japan); Fujibuchi, Toshioh [Department of Radiological Sciences, School of Health Science, Ibaraki Prefectural University, Inashiki-gun, Ibaraki 300-0394, Japan and Graduate School of Comprehensive Human Sciences, University of Tsukuba, Tsukuba-shi, Ibaraki 305-8575 (Japan); Nishio, Teiji [Particle Therapy Division, Research Center for Innovation Oncology, National Cancer Center Hospital East, Kashiwa-shi, Chiba 277-8577 (Japan); Nakagawa, Keiichi [Division of Radiology and Biomedical Engineering, Graduate School of Medicine, The University of Tokyo, Bunkyo-ku, Tokyo 113-8655 (Japan)

    2009-04-15

    Computed radiography (CR) is gradually replacing film. The application of CR for two-dimensional profiles and off-axis ratio (OAR) measurement using an imaging plate (IP) in a CR system is currently under discussion. However, a well known problem for IPs in dosimetry is that they use high atomic number (Z) materials, such as Ba, which have an energy dependency in a photon interaction. Although there are some reports that it is possible to compensate for the energy dependency with metal filters, the appropriate thicknesses of these filters and where they should be located have not been investigated. The purpose of this study is to find the most suitable filter for use with an IP as a dosimetric tool. Monte Carlo simulation (Geant4 8.1) was used to determine the filter to minimize the measurement error in OAR measurements of 4 MV x-rays. In this simulation, the material and thickness of the filter and distance between the IP and the filter were varied to determine most suitable filter conditions that gave the best fit to the MC calculated OAR in water. With regard to changing the filter material, we found that using higher Z and higher density material increased the effectiveness of the filter. Also, increasing the distance between the filter and the IP reduced the effectiveness, whereas increasing the thickness of the filter increased the effectiveness. The result of this study showed that the most appropriate filter conditions consistent with the calculated OAR in water were the ones with the IP sandwiched between two 2 mm thick lead filters at a distance of 5 mm from the IP or the IP sandwiched directly between two 1 mm lead filters. Using these filters, we measured the OAR at 10 cm depth with 100 cm source-to-surface distance and surface 10x10 cm{sup 2} field size. The results of this measurement represented that it is possible to achieve measurements with less than within 2.0% and 2.0% in the field and with less than 1.1% and 0.6% out of the field by using 2 and

  5. Technical note: optimization for improved tube-loading efficiency in the dual-energy computed tomography coupled with balanced filter method.

    Science.gov (United States)

    Saito, Masatoshi

    2010-08-01

    This article describes the spectral optimization of dual-energy computed tomography using balanced filters (bf-DECT) to reduce the tube loadings and dose by dedicating to the acquisition of electron density information, which is essential for treatment planning in radiotherapy. For the spectral optimization of bf-DECT, the author calculated the beam-hardening error and air kerma required to achieve a desired noise level in an electron density image of a 50-cm-diameter cylindrical water phantom. The calculation enables the selection of beam parameters such as tube voltage, balanced filter material, and its thickness. The optimal combination of tube voltages was 80 kV/140 kV in conjunction with Tb/Hf and Bi/Mo filter pairs; this combination agrees with that obtained in a previous study [M. Saito, "Spectral optimization for measuring electron density by the dual-energy computed tomography coupled with balanced filter method," Med. Phys. 36, 3631-3642 (2009)], although the thicknesses of the filters that yielded a minimum tube output were slightly different from those obtained in the previous study. The resultant tube loading of a low-energy scan of the present bf-DECT significantly decreased from 57.5 to 4.5 times that of a high-energy scan for conventional DECT. Furthermore, the air kerma of bf-DECT could be reduced to less than that of conventional DECT, while obtaining the same figure of merit for the measurement of electron density and effective atomic number. The tube-loading and dose efficiencies of bf-DECT were considerably improved by sacrificing the quality of the noise level in the images of effective atomic number.

  6. Noise reduction and functional maps image quality improvement in dynamic CT perfusion using a new k-means clustering guided bilateral filter (KMGB).

    Science.gov (United States)

    Pisana, Francesco; Henzler, Thomas; Schönberg, Stefan; Klotz, Ernst; Schmidt, Bernhard; Kachelrieß, Marc

    2017-07-01

    features of the filter, resulting in improved spatial resolution and CNR both for CT images and for functional maps. In the phantom study, the PATEN filter showed overall the poorest results, while the other filters showed comparable performances in terms of perfusion values preservation, with the KMGB filter having overall the best image quality. In conclusion, the KMGB filter leads to superior results for CT images and functional maps quality improvement, in significantly shorter computational times compared to the other filters. Our results suggest that the KMGB filter might be a more robust solution for halved-dose CTP datasets. For all the filters investigated, some artifacts start to appear on the BF maps if one sixth of the dose is simulated, suggesting that no one of the filters investigated in this study might be optimal for such a drastic dose reduction scenario. © 2017 American Association of Physicists in Medicine.

  7. Photoplethysmogram signal quality estimation using repeated Gaussian filters and cross-correlation

    International Nuclear Information System (INIS)

    Karlen, W; Kobayashi, K; Dumont, G A; Ansermino, J M

    2012-01-01

    Pulse oximeters are monitors that noninvasively measure heart rate and blood oxygen saturation (SpO 2 ). Unfortunately, pulse oximetry is prone to artifacts which negatively impact the accuracy of the measurement and can cause a significant number of false alarms. We have developed an algorithm to segment pulse oximetry signals into pulses and estimate the signal quality in real time. The algorithm iteratively calculates a signal quality index (SQI) ranging from 0 to 100. In the presence of artifacts and irregular signal morphology, the algorithm outputs a low SQI number. The pulse segmentation algorithm uses the derivative of the signal to find pulse slopes and an adaptive set of repeated Gaussian filters to select the correct slopes. Cross-correlation of consecutive pulse segments is used to estimate signal quality. Experimental results using two different benchmark data sets showed a good pulse detection rate with a sensitivity of 96.21% and a positive predictive value of 99.22%, which was equivalent to the available reference algorithm. The novel SQI algorithm was effective and produced significantly lower SQI values in the presence of artifacts compared to SQI values during clean signals. The SQI algorithm may help to guide untrained pulse oximeter users and also help in the design of advanced algorithms for generating smart alarms. (paper)

  8. Photoplethysmogram signal quality estimation using repeated Gaussian filters and cross-correlation.

    Science.gov (United States)

    Karlen, W; Kobayashi, K; Ansermino, J M; Dumont, G A

    2012-10-01

    Pulse oximeters are monitors that noninvasively measure heart rate and blood oxygen saturation (SpO2). Unfortunately, pulse oximetry is prone to artifacts which negatively impact the accuracy of the measurement and can cause a significant number of false alarms. We have developed an algorithm to segment pulse oximetry signals into pulses and estimate the signal quality in real time. The algorithm iteratively calculates a signal quality index (SQI) ranging from 0 to 100. In the presence of artifacts and irregular signal morphology, the algorithm outputs a low SQI number. The pulse segmentation algorithm uses the derivative of the signal to find pulse slopes and an adaptive set of repeated Gaussian filters to select the correct slopes. Cross-correlation of consecutive pulse segments is used to estimate signal quality. Experimental results using two different benchmark data sets showed a good pulse detection rate with a sensitivity of 96.21% and a positive predictive value of 99.22%, which was equivalent to the available reference algorithm. The novel SQI algorithm was effective and produced significantly lower SQI values in the presence of artifacts compared to SQI values during clean signals. The SQI algorithm may help to guide untrained pulse oximeter users and also help in the design of advanced algorithms for generating smart alarms.

  9. Series active power filter in power conditioning

    Energy Technology Data Exchange (ETDEWEB)

    Turunen, J.

    2009-07-01

    Power quality has become an important issue nowadays for several reasons, e.g. modern society's growing dependence on electricity and the fact that poor power quality may generate significant economic losses in few moments. Probable power quality problems are, e.g. harmonics, flicker, voltage dips and supply interruptions. The power quality may be improved by using filters and compensators.The purpose of this thesis is to research the operation of the series active power filter (SAPF) in power conditioning. Therefore, this thesis presents a comparison of three series hybrid active power filters (SHAPFs) in current harmonics filtering. In addition to this, it is shown how the voltage dip compensation performance of the SAPF is improved in a unified power quality conditioner (UPQC) application.The three SHAPFs included in the comparison are series connected topology (SCT), filter connected topology (FCT) and electrically tuned LC shunt circuit (ETLC). The operating principle of these filters is to direct the harmonic currents produced by the load to flow in the LC shunt circuits instead of the supply. In the case of the SCT this phenomenon is boosted by applying so-called active resistance in the supply branch using the SAPF. In the case of the FCT a similar action is achieved by applying the compensation voltage in series with the LC shunt circuits using the SAPF. In the case of the ETLC the performance of the LC shunt circuit is enhanced by applying so-called active inductances in series with the LC shunt circuit using the SAPF. The SHAPFs are compared by searching for their best current filtering performance using various main circuit and control system configurations and loads. The operation of the SHAPFs is first analysed mathematically. After this, the current filtering performance of the SHAPFs is inspected using simulations and experimental tests. The experimental tests are carried out using SHAPF prototypes. As a result, it is shown that the current

  10. Effects of sawdust thickness on the growth performance, environmental condition, and welfare quality of yellow broilers.

    Science.gov (United States)

    Shao, Dan; He, Jiao; Lu, Jian; Wang, Qiang; Chang, Lingling; Shi, Shou Rong; Bing, Tong Hai

    2015-01-01

    An experiment was conducted to evaluate the effect of litter thickness on growth performance, immune status, environmental condition, and welfare quality in yellow broilers. In total, 1,800 one-day-old Suqin yellow broilers were raised for 21 d. On d 22, 1,600 birds of similar BW (404±12 g) were randomly selected and placed into 20 indoor pens (8 birds/m2, 10 m2/pen). These birds were assigned to a litter treatment of 4, 8, 12, and 16 cm. Each treatment was repeated in five pens. The results showed that a thicker litter was related to increased BW, daily weight gain, and daily feed intake (Plitter thickness (P=0.320, P=0.353, respectively). Absolute and relative liver weights showed a significant linear response to increasing litter thickness (P=0.01, P=0.001, respectively). The litter moisture content, air ammonia, and CO2 content decreased, whereas the air dust content increased with increasing litter thickness (PLitter thickness had no effect on gait, plumage damage, hock burn or breast skin crusting (P = 0.076, P=0.964, P=0.131, P=0.401, respectively). Plumage cleanliness, foot pad dermatitis, hock swelling and breast blister varied significantly with litter thickness (P=0.027, P=0.011, P=0.014, P=0.042, respectively). The results of this study suggest that an increasing litter thickness has a beneficial effect on the growth performance, environmental condition and welfare of birds. © 2015 Poultry Science Association Inc.

  11. Filtering Photogrammetric Point Clouds Using Standard LIDAR Filters Towards DTM Generation

    Science.gov (United States)

    Zhang, Z.; Gerke, M.; Vosselman, G.; Yang, M. Y.

    2018-05-01

    Digital Terrain Models (DTMs) can be generated from point clouds acquired by laser scanning or photogrammetric dense matching. During the last two decades, much effort has been paid to developing robust filtering algorithms for the airborne laser scanning (ALS) data. With the point cloud quality from dense image matching (DIM) getting better and better, the research question that arises is whether those standard Lidar filters can be used to filter photogrammetric point clouds as well. Experiments are implemented to filter two dense matching point clouds with different noise levels. Results show that the standard Lidar filter is robust to random noise. However, artefacts and blunders in the DIM points often appear due to low contrast or poor texture in the images. Filtering will be erroneous in these locations. Filtering the DIM points pre-processed by a ranking filter will bring higher Type II error (i.e. non-ground points actually labelled as ground points) but much lower Type I error (i.e. bare ground points labelled as non-ground points). Finally, the potential DTM accuracy that can be achieved by DIM points is evaluated. Two DIM point clouds derived by Pix4Dmapper and SURE are compared. On grassland dense matching generates points higher than the true terrain surface, which will result in incorrectly elevated DTMs. The application of the ranking filter leads to a reduced bias in the DTM height, but a slightly increased noise level.

  12. Do blue-light filtering intraocular lenses affect visual function?

    Science.gov (United States)

    Lavric, Alenka; Pompe, Manca Tekavcic

    2014-11-01

    To study different aspects of visual function, macular changes, and subjective differences between the eye with an ultraviolet (UV) and blue-light filtering intraocular lens (IOL) and the fellow eye with a UV-light filtering IOL. Thirty patients (60 eyes) with senile cataract had both cataracts extracted, and an IOL was implanted at least 2 years before clinical evaluation. In one eye, AcrySof SA60AT (a UV-light filtering IOL) was implanted, whereas in the contralateral eye, AcrySof IQ SN60WF (a blue-light filtering IOL) was implanted. Each patient underwent visual acuity testing, color vision testing (Ishihara and Farnsworth-Munsell 100-hue tests), and contrast sensitivity (CS) testing. The macula was evaluated with optical coherence tomography and with clinical examination. Patients were asked if they noted any difference between the implanted IOLs concerning visual impression. Subjective visual quality was evaluated using the National Eye Institute Visual Functioning Questionnaire. There was a borderline statistically significant difference in the mean best-corrected visual acuity (p = 0.05). As regards color vision, no significant changes in Ishihara and Farnsworth-Munsell 100-hue error scores were detected between both eyes (p = 0.48 and p = 0.59, respectively). Analysis of CS showed no significant difference between the groups at any spatial frequency. There were also no statistically significant differences in central macular thickness and total macular volume between the two IOL groups (p = 0.72 and p = 0.61, respectively). In both IOL groups, three eyes developed an epiretinal membrane, and six eyes developed early signs of age-related macular degeneration. This study showed no significant effects of a blue-light filtering IOL on visual acuity and no influence on color perception and CS. After more than 2 years, there were no significant differences in macular changes between the IOL groups. Clinical evidence of the effect of a blue-light filtering IOL on

  13. Quality assurance in thick-walled weldments

    International Nuclear Information System (INIS)

    Straub, H.

    1978-01-01

    Some guidelines are given here for judging the magnitude of flaws in welded thick-walled components (such as nuclear reactor vessels). The actually critical defect sizes are analysed, taking into account the residual stresses after welding and after annealing also. Various procedures for repairing such work are then indicated. (Auth.)

  14. Definition of parameters for quality assurance of flattening filter free (FFF) photon beams in radiation therapy

    International Nuclear Information System (INIS)

    Fogliata, A.; Garcia, R.; Knöös, T.; Nicolini, G.; Clivio, A.; Vanetti, E.; Khamphan, C.; Cozzi, L.

    2012-01-01

    Purpose: Flattening filter free (FFF) beams generated by medical linear accelerators have recently started to be used in radiotherapy clinical practice. Such beams present fundamental differences with respect to the standard filter flattened (FF) beams, making the generally used dosimetric parameters and definitions not always viable. The present study will propose possible definitions and suggestions for some dosimetric parameters for use in quality assurance of FFF beams generated by medical linacs in radiotherapy. Methods: The main characteristics of the photon beams have been analyzed using specific data generated by a Varian TrueBeam linac having both FFF and FF beams of 6 and 10 MV energy, respectively. Results: Definitions for dose profile parameters are suggested starting from the renormalization of the FFF with respect to the corresponding FF beam. From this point the flatness concept has been translated into one of “unflatness” and other definitions have been proposed, maintaining a strict parallelism between FFF and FF parameter concepts. Conclusions: Ideas for quality controls used in establishing a quality assurance program when introducing FFF beams into the clinical environment are given here, keeping them similar to those used for standard FF beams. By following the suggestions in this report, the authors foresee that the introduction of FFF beams into a clinical radiotherapy environment will be as safe and well controlled as standard beam modalities using the existing guidelines.

  15. DOE standard: Filter test facility quality program plan

    International Nuclear Information System (INIS)

    1999-02-01

    This standard was developed primarily for application in US Department of Energy programs. It contains specific direction for HEPA filter testing performed at a DOE-accepted HEPA Filter Test Facility (FTF). Beneficial comments (recommendations, additions, deletions) and any pertinent data that may improve this document should be sent to the Office of Nuclear Safety Policy and Standards (EH-31), US Department of Energy, Washington, DC 20585, by letter or by using the self-addressed Document Improvement Proposal form (DOE F 1300.3) appearing at the end of this document

  16. Comparative study of reconstruction filters for cranio examinations of the Philips system and its influence on the quality of the tomographic image

    International Nuclear Information System (INIS)

    Silveira, V.C.; Kodlulovich, S.; Delduck, R.S.; Oliveira, L.C.G.

    2011-01-01

    The aim of this study was to evaluate different reconstruction algorithm (kernels) applied for head examinations. The research was carried out using 40-slice MDCT (Philips, Brilliance 40 CT scanner) and an ACR Phantoms to evaluate the image quality. The doses were estimated applying the coefficients obtained by IMPACT .The study showed that independently of the filter used the values of CT number have no change. The low contrast showed that the choice of correct filter might result a decrease of 9% of doses values. For special resolution, the sharp filter showed a better response for low m As. The noise value of image to certain filters smooth has no changed, even by reducing the m As values. (author)

  17. Sediment quality guidelines for copper and zinc for filter-feeding estuarine oysters?

    International Nuclear Information System (INIS)

    Birch, G.F.; Hogg, T.D.

    2011-01-01

    Sediment quality guidelines (SQGs) assess the ability of bottom sediment to sustain healthy infauna and water quality guidelines (WQGs) provide protection for a designated percentage of aquatic species. Filter-feeding marine species, e.g. oysters and mussels, acquire food from particles in the water column and protection of these animals is not provided by SQGs or WQGs. The current work investigated the relationship between metal (Cu, Zn) concentrations in total and fine-fraction ( -1 and -1 , respectively) for protecting oysters from exceeding human consumption levels (70 μg g -1 and 1000 μg g -1 , respectively). - A strong correlation between oyster tissue Cu and Zn concentrations and fine-fraction surficial sediment digested in 1 M HCl provided a sedimentary guideline which predicted tissue metal concentrations in oysters and established a level for protecting oysters from exceeding human consumption levels for these metals. The guidelines for fine surficial sediment developed in the present work accurately predicted oyster tissue concentrations in the field.

  18. Effect of rib fat thickness on the quality of aged meat from Nellore young bulls

    Directory of Open Access Journals (Sweden)

    Erick Escobar Dallantonia

    2015-05-01

    Full Text Available This trial aimed to evaluate the quality of aged beef from Nellore young bulls under two yield grade (YG. Fourteen animals with approximately 450 ± 30 kg body weight were evaluated for backfat thickness (BFT at the beginning of the experimental period. Seven animals had BFT of 0-3 mm and seven animals, 3.1-6 mm. Two groups were formed at the end of the experiment: animals finished with 3-6 mm BFT (seven animals and animals finished with 6.1 to 10 mm BFT (seven animals. Every 28 days, we evaluated by ultrasound the BFT between the 12nd 13rd ribs. There was no interaction between YG and aging for beef color, pH, cooking losses and shear force (p > 0.05. There was no effect of YG on sarcomere length (p = 0.11. However, there was interaction between YG and aging on water holding capacity (p < 0.01. The yield grades evaluated did not interfere with meat quality, but carcasses with 6.1 - 10 mm of backfat thickness showed highest water holding capacity. The aging of the longissimus muscle for up to 14 days improves beef tenderness.

  19. Personal Dosemeter of Thermal Neutron Using A Cr-39 Detector with Filter Natural LiF

    International Nuclear Information System (INIS)

    Sofyan, Hasnel; Thamrin, M.Thoyib

    1996-01-01

    The research of personal dosemeter for thermal neutron using Cr-39 detector with different thicknesses of natural LiF filter was carried out. The irradiation of Cr-39 detector with neutron source from reactor research TRIGA mark II of Rikkyo University Tokyo, Japan. Nuclear track was counted by automatic method with ASPECT ver.4.22 Series A4T124 software and manual method for correction. The result of research, the maximum of nuclear tracks was obtained at 8 mm of LiF filter was 10 mm with 11,630x10E-5 track/neutron for air radiation. And on phantom radiation, the thickness of filter was 10 mm with 11,630x10E-5 track/neutron. Its values were 3.6 and 7.5 bigger than the response of Cr-39 non filter in air and on phantom radiation, respectively

  20. Observation Quality Control with a Robust Ensemble Kalman Filter

    KAUST Repository

    Roh, Soojin

    2013-12-01

    Current ensemble-based Kalman filter (EnKF) algorithms are not robust to gross observation errors caused by technical or human errors during the data collection process. In this paper, the authors consider two types of gross observational errors, additive statistical outliers and innovation outliers, and introduce a method to make EnKF robust to gross observation errors. Using both a one-dimensional linear system of dynamics and a 40-variable Lorenz model, the performance of the proposed robust ensemble Kalman filter (REnKF) was tested and it was found that the new approach greatly improves the performance of the filter in the presence of gross observation errors and leads to only a modest loss of accuracy with clean, outlier-free, observations.

  1. Observation Quality Control with a Robust Ensemble Kalman Filter

    KAUST Repository

    Roh, Soojin; Genton, Marc G.; Jun, Mikyoung; Szunyogh, Istvan; Hoteit, Ibrahim

    2013-01-01

    Current ensemble-based Kalman filter (EnKF) algorithms are not robust to gross observation errors caused by technical or human errors during the data collection process. In this paper, the authors consider two types of gross observational errors, additive statistical outliers and innovation outliers, and introduce a method to make EnKF robust to gross observation errors. Using both a one-dimensional linear system of dynamics and a 40-variable Lorenz model, the performance of the proposed robust ensemble Kalman filter (REnKF) was tested and it was found that the new approach greatly improves the performance of the filter in the presence of gross observation errors and leads to only a modest loss of accuracy with clean, outlier-free, observations.

  2. Comparison of anode/filter combinations in digital mammography with respect to the average glandular dose

    International Nuclear Information System (INIS)

    Uhlenbrock, D.F.; Mertelmeier, Thomas

    2009-01-01

    To investigate the average glandular dose (AGD) applied for clinical digital mammograms acquired with the anode/filter combinations molybdenum/molybdenum (Mo/Mo), molybdenum/rhodium (Mo/Rh), and tungsten/rhodium (W/Rh). Using the method of Dance, the AGD was evaluated from the exposure data of 4867 digital mammograms at two sites equipped with a full-field digital mammography (FFDM) system based on an amorphous selenium detector. 1793 images were acquired and analyzed with Mo/Mo, 643 with Mo/Rh, and 2431 with W/Rh. In the Mo/Mo cases the mean compressed breast thickness was 46 ± 10 mm with an average AGD of 2.29 ± 1.31 mGy. For the Mo/Rh cases with a mean compressed thickness of 64 ± 9 mm, we obtained 2.76 ± 1.31 mGy. The W/Rh cases with a mean compressed thickness of 52 ± 13 mm resulted in 1.26 ± 0.44 mGy. The image quality was assessed as normal and adequate for diagnostic purposes in all cases. (orig.)

  3. Study of the additional filter in transcatheter hepatic arterial embolization

    International Nuclear Information System (INIS)

    Hitomi, Go; Arao, Shinichi; Tomomitsu, Tatsushi

    2010-01-01

    It is well known that Interventional Radiology (IVR) is useful. However, the patient dose in IVR is increasing because of the prolongation of fluoroscopic time and the increase in the number of radiographies in recent years. We studied the adequacy of the additional filter for the decrease of the skin surface dose in patients with hepatocellular carcinoma of transcatheter arterial embolization (TAE). In 20 patients (15 men and 5 women, average age: 66.9 and 72.0 years old) who had undergone TAE, we estimated the skin surface dose from the records of their exposure condition (tube voltage, tube current, time, and field size of image intensifier) and the results of the phantom experiment with 2 kinds of additional filter. The estimated skin surface dose of the patient was 1.75±0.84 with the additional filter of 1.5 mm thickness of aluminum (1.5 mmAl), 1.46±0.67 Gy with 0.03 mm thickness tantalum (0.03 mmTa) and 1.17±0.55 Gy with 0.06 mm thickness of tantalum (0.06 mmTa). Against a skin surface dose of 1.5 mmAl, the dose reduction of 16.7% was shown in 0.03 mmTa and 33.2% in 0.06 mmTa. With a digital subtraction angiography (DSA) phantom of iodine density 0.5 and 1.0 and 2.0 mgI/ml, DSA images were acquisitioned at tube voltage 70, 80 and 90 kV to compare the detectability of contrast media in 0.06 mmTa with 1.5 mmAl. To evaluate the detectability of contrast media in 0.06 mmTa in 1.5 mmAl, receiver operating characteristic (ROC) analysis was performed with the pixel value of the phantom image. The area under the ROC curve in a 1.5 mmAl filter and the 0.06 mmTa filter provided with each contrast media density and each tube voltage was approximately a constant value. It was suggested that there was no differences in the detectability of contrast media in both additional filters. In conclusion, the skin surface dose of the patient was able to be reduced 33.2% without decreasing contrast media detectability by changing the additional filter from 1.5 mmAl to 0.06 mm

  4. Optimizing detection filters for single-grain optical dating of quartz

    International Nuclear Information System (INIS)

    Ballarini, M.; Wallinga, J.; Duller, G.A.T.; Brouwer, J.C.; Bos, A.J.J.; Van Eijk, C.W.E.

    2005-01-01

    We investigate the use of different optical detection filters for single-grain optically stimulated luminescence (OSL) measurements of quartz samples with a Riso TL/OSL single-grain reader. We selected three filter combinations that considerably improve the light detection efficiency when compared with the 7.5 mm U340 filters that are routinely used. These are the UG1+BG4 filter combination, the 2 mm UG1 and the 2.5 mm U340 filters, which allow a greater transmission in the quartz emission band. This leads to two benefits: (1) more grains can be accepted for equivalent dose analysis, and (2) OSL responses on individual grains are determined with a greater precision. While these three alternative filter combinations perform equally well if compared to each other, we suggest the 2.5 mm thick Hoya U340 to be the filter of choice as it allows the use of blue-diode and IR-diode stimulation sources for bleaching purposes and feldspar detection

  5. Design and manufacture of super-multilayer optical filters based on PARMS technology

    Science.gov (United States)

    Lü, Shaobo; Wang, Ruisheng; Ma, Jing; Jiang, Chao; Mu, Jiali; Zhao, Shuaifeng; Yin, Xiaojun

    2018-04-01

    Three multilayer interference optical filters, including a UV band-pass, a VIS dual-band-pass and a notch filter, were designed by using Ta2O5, Nb2O5, Al2O3 and SiO2 as high- and low-index materials. During the design of the coating process, a hybrid optical monitoring and RATE-controlled layer thickness control scheme was adopted. The coating process was simulated by using the optical monitoring system (OMS) Simulator, and the simulation result indicated that the layer thickness can be controlled within an error of less than ±0.1%. The three filters were manufactured on a plasma-assisted reactive magnetic sputtering (PARMS) coating machine. The measurements indicate that for the UV band-pass filter, the peak transmittance is higher than 95% and the blocking density is better than OD6 in the 300-1100 nm region, whereas for the dual-band-pass filter, the center wavelength positioning accuracy of the two passbands are less than ±2 nm, the peak transmittance is higher than 95% and blocking density is better than OD6 in the 300-950 nm region. Finally, for the notch filter, the minimum transmittance rates are >90% and >94% in the visible and near infrared, respectively, and the blocking density is better than OD5.5 at 808 nm.

  6. UWB Bandpass Filter with Ultra-wide Stopband based on Ring Resonator

    Science.gov (United States)

    Kazemi, Maryam; Lotfi, Saeedeh; Siahkamari, Hesam; Mohammadpanah, Mahmood

    2018-04-01

    An ultra-wideband (UWB) bandpass filter with ultra-wide stopband based on a rectangular ring resonator is presented. The filter is designed for the operational frequency band from 4.10 GHz to 10.80 GHz with an ultra-wide stopband from 11.23 GHz to 40 GHz. The even and odd equivalent circuits are used to achieve a suitable analysis of the proposed filter performance. To verify the design and analysis, the proposed bandpass filter is simulated using full-wave EM simulator Advanced Design System and fabricated on a 20mil thick Rogers_RO4003 substrate with relative permittivity of 3.38 and a loss tangent of 0.0021. The proposed filter behavior is investigated and simulation results are in good agreement with measurement results.

  7. Moiré volume Bragg grating filter with tunable bandwidth.

    Science.gov (United States)

    Mokhov, Sergiy; Ott, Daniel; Divliansky, Ivan; Zeldovich, Boris; Glebov, Leonid

    2014-08-25

    We propose a monolithic large-aperture narrowband optical filter based on a moiré volume Bragg grating formed by two sequentially recorded gratings with slightly different resonant wavelengths. Such recording creates a spatial modulation of refractive index with a slowly varying sinusoidal envelope. By cutting a specimen at a small angle, to a thickness of one-period of this envelope, the longitudinal envelope profile will shift from a sine profile to a cosine profile across the face of the device. The transmission peak of the filter has a tunable bandwidth while remaining at a fixed resonant wavelength by a transversal shift of incidence position. Analytical expressions for the tunable bandwidth of such a filter are calculated and experimental data from a filter operating at 1064 nm with bandwidth range 30-90 pm is demonstrated.

  8. Development of High Quality 4H-SiC Thick Epitaxy for Reliable High Power Electronics Using Halogenated Precursors

    Science.gov (United States)

    2016-08-02

    defects :=()llowed by a second buffer epilayer gro\\\\ th with ~: urn thickness with high n-type dopi:1g (- 5£17 cm-3) for the same C/Si ratio of ~1.4 at...gradient, pressure , etc.) can further reduce the parasitic deposition, especially in TFS-growth. • Thick epitaxy on-axis 4H-SiC Growth at High Growth...From - To) 08/02/2016 Final Technical Report 01-Apr-10 Through 31-Mar-14 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER Development of High Quality 4H

  9. The efficacy of K-edge filters in diagnostic radiology

    International Nuclear Information System (INIS)

    Williamson, B.D.P.; van Doorn, T.

    1994-01-01

    The application of K-edge filters in diagnostic has been investigated by many workers for over twenty years. These investigations have analysed the effects of such filters on image quality and radiation dose as well as the practicalities of their application. This paper presents a synopsis of the published works and concludes that K-edge filters do not perceptibly improve image quality and make only limited reductions in patient dose. K-edge filters are also costly to purchase and potentially result in a reduction in the cost effectiveness of x-ray examinations by increasing the x-ray tube loading. Equivalent contrast enhancement and dose reductions can be achieved by the assiduous choice of non-selective filters. 51 refs., 2 tab., 6 figs

  10. Hybrid Filter Membrane

    Science.gov (United States)

    Laicer, Castro; Rasimick, Brian; Green, Zachary

    2012-01-01

    Cabin environmental control is an important issue for a successful Moon mission. Due to the unique environment of the Moon, lunar dust control is one of the main problems that significantly diminishes the air quality inside spacecraft cabins. Therefore, this innovation was motivated by NASA s need to minimize the negative health impact that air-suspended lunar dust particles have on astronauts in spacecraft cabins. It is based on fabrication of a hybrid filter comprising nanofiber nonwoven layers coated on porous polymer membranes with uniform cylindrical pores. This design results in a high-efficiency gas particulate filter with low pressure drop and the ability to be easily regenerated to restore filtration performance. A hybrid filter was developed consisting of a porous membrane with uniform, micron-sized, cylindrical pore channels coated with a thin nanofiber layer. Compared to conventional filter media such as a high-efficiency particulate air (HEPA) filter, this filter is designed to provide high particle efficiency, low pressure drop, and the ability to be regenerated. These membranes have well-defined micron-sized pores and can be used independently as air filters with discreet particle size cut-off, or coated with nanofiber layers for filtration of ultrafine nanoscale particles. The filter consists of a thin design intended to facilitate filter regeneration by localized air pulsing. The two main features of this invention are the concept of combining a micro-engineered straight-pore membrane with nanofibers. The micro-engineered straight pore membrane can be prepared with extremely high precision. Because the resulting membrane pores are straight and not tortuous like those found in conventional filters, the pressure drop across the filter is significantly reduced. The nanofiber layer is applied as a very thin coating to enhance filtration efficiency for fine nanoscale particles. Additionally, the thin nanofiber coating is designed to promote capture of

  11. Use of metameric filters for future interference security image structures

    Science.gov (United States)

    Baloukas, Bill; Larouche, Stéphane; Martinu, Ludvik

    2006-02-01

    In the present work, we describe innovative approaches and properties that can be added to the already popular thin film optically variable devices (OVD) used on banknotes. We show two practical examples of OVDs, namely (i) a pair of metameric filters offering a hidden image effect as a function of the angle of observation as well as a specific spectral property permitting automatic note readability, and (ii) multi-material filters offering a side-dependent color shift. We first describe the design approach of these new devices followed by their sensitivity to deposition errors especially in the case of the metameric filters where slight thickness variations have a significant effect on the obtained colors. The performance of prototype filters prepared by dual ion beam sputtering (DIBS) is shown.

  12. MR image reconstruction via guided filter.

    Science.gov (United States)

    Huang, Heyan; Yang, Hang; Wang, Kang

    2018-04-01

    Magnetic resonance imaging (MRI) reconstruction from the smallest possible set of Fourier samples has been a difficult problem in medical imaging field. In our paper, we present a new approach based on a guided filter for efficient MRI recovery algorithm. The guided filter is an edge-preserving smoothing operator and has better behaviors near edges than the bilateral filter. Our reconstruction method is consist of two steps. First, we propose two cost functions which could be computed efficiently and thus obtain two different images. Second, the guided filter is used with these two obtained images for efficient edge-preserving filtering, and one image is used as the guidance image, the other one is used as a filtered image in the guided filter. In our reconstruction algorithm, we can obtain more details by introducing guided filter. We compare our reconstruction algorithm with some competitive MRI reconstruction techniques in terms of PSNR and visual quality. Simulation results are given to show the performance of our new method.

  13. Intraindividual evaluation of the influence of iterative reconstruction and filter kernel on subjective and objective image quality in computed tomography of the brain

    Energy Technology Data Exchange (ETDEWEB)

    Buhk, J.H. [Univ. Medical Center, Hamburg-Eppendorf (Germany). Dept. of Neuroradiology; Laqmani, A.; Schultzendorff, H.C. von; Hammerle, D.; Adam, G.; Regier, M. [Univ. Medical Center, Hamburg-Eppendorf (Germany). Dept. of Diagnostic and Interventional Radiology; Sehner, S. [Univ. Medical Center, Hamburg-Eppendorf (Germany). Inst. of Medical Biometry and Epidemiology; Fiehler, J. [Univ. Medical Center, Hamburg-Eppendorf (Germany). Neuroradiology; Nagel, H.D. [Dr. HD Nagel, Science and Technology for Radiology, Buchholz (Germany)

    2013-08-15

    Objectives: To intraindividually evaluate the potential of 4th generation iterative reconstruction (IR) on brain CT with regard to subjective and objective image quality. Methods: 31 consecutive raw data sets of clinical routine native sequential brain CT scans were reconstructed with IR level 0 (= filtered back projection), 1, 3 and 4; 3 different brain filter kernels (smooth/standard/sharp) were applied respectively. Five independent radiologists with different levels of experience performed subjective image rating. Detailed ROI analysis of image contrast and noise was performed. Statistical analysis was carried out by applying a random intercept model. Results: Subjective scores for the smooth and the standard kernels were best at low IR levels, but both, in particular the smooth kernel, scored inferior with an increasing IR level. The sharp kernel scored lowest at IR 0, while the scores substantially increased at high IR levels, reaching significantly best scores at IR 4. Objective measurements revealed an overall increase in contrast-to-noise ratio at higher IR levels, which was highest when applying the soft filter kernel. The absolute grey-white contrast decreased with an increasing IR level and was highest when applying the sharp filter kernel. All subjective effects were independent of the raters' experience and the patients' age and sex. Conclusion: Different combinations of IR level and filter kernel substantially influence subjective and objective image quality of brain CT. (orig.)

  14. Intraindividual evaluation of the influence of iterative reconstruction and filter kernel on subjective and objective image quality in computed tomography of the brain

    International Nuclear Information System (INIS)

    Buhk, J.H.

    2013-01-01

    Objectives: To intraindividually evaluate the potential of 4th generation iterative reconstruction (IR) on brain CT with regard to subjective and objective image quality. Methods: 31 consecutive raw data sets of clinical routine native sequential brain CT scans were reconstructed with IR level 0 (= filtered back projection), 1, 3 and 4; 3 different brain filter kernels (smooth/standard/sharp) were applied respectively. Five independent radiologists with different levels of experience performed subjective image rating. Detailed ROI analysis of image contrast and noise was performed. Statistical analysis was carried out by applying a random intercept model. Results: Subjective scores for the smooth and the standard kernels were best at low IR levels, but both, in particular the smooth kernel, scored inferior with an increasing IR level. The sharp kernel scored lowest at IR 0, while the scores substantially increased at high IR levels, reaching significantly best scores at IR 4. Objective measurements revealed an overall increase in contrast-to-noise ratio at higher IR levels, which was highest when applying the soft filter kernel. The absolute grey-white contrast decreased with an increasing IR level and was highest when applying the sharp filter kernel. All subjective effects were independent of the raters' experience and the patients' age and sex. Conclusion: Different combinations of IR level and filter kernel substantially influence subjective and objective image quality of brain CT. (orig.)

  15. MO-FG-CAMPUS-IeP1-01: Alternative K-Edge Filters for Low-Energy Image Acquisition in Contrast Enhanced Spectral Mammography

    Energy Technology Data Exchange (ETDEWEB)

    Shrestha, S; Vedantham, S; Karellas, A [University of Massachusetts Medical School, Worcester, MA (United States)

    2016-06-15

    Purpose: In Contrast Enhanced Spectral Mammography (CESM), Rh filter is often used during low-energy image acquisition. The potential for using Ag, In and Sn filters, which exhibit K-edge closer to, and just below that of Iodine, instead of the Rh filter, was investigated for the low-energy image acquisition. Methods: Analytical computations of the half-value thickness (HVT) and the photon fluence per mAs (photons/mm2/mAs) for 50µm Rh were compared with other potential K-edge filters (Ag, In and Sn), all with K-absorption edge below that of Iodine. Two strategies were investigated: fixed kVp and filter thickness (50µm for all filters) resulting in HVT variation, and fixed kVp and HVT resulting in variation in Ag, In and Sn thickness. Monte Carlo simulations (GEANT4) were conducted to determine if the scatter-to-primary ratio (SPR) and the point spread function of scatter (scatter PSF) differed between Rh and other K-edge filters. Results: Ag, In and Sn filters (50µm thick) increased photon fluence/mAs by 1.3–1.4, 1.8–2, and 1.7–2 at 28-32 kVp compared to 50µm Rh, which could decrease exposure time. Additionally, the fraction of spectra closer to and just below Iodine’s K-edge increased with these filters, which could improve post-subtraction image contrast. For HVT matched to 50µm Rh filtered spectra, the thickness range for Ag, In, and Sn were (41,44)µm, (49,55)µm and (45,53)µm, and increased photon fluence/mAs by 1.5–1.7, 1.6–2, and 1.6–2.2, respectively. Monte Carlo simulations showed that neither the SPR nor the scatter PSF of Ag, In and Sn differed from Rh, indicating no additional detriment due to x-ray scatter. Conclusion: The use of Ag, In and Sn filters for low-energy image acquisition in CESM is potentially feasible and could decrease exposure time and may improve post-subtraction image contrast. Effect of these filters on radiation dose, contrast, noise and associated metrics are being investigated. Funding Support: Supported in

  16. Planar Superconducting Millimeter-Wave/Terahertz Channelizing Filter

    Science.gov (United States)

    Ehsan, Negar; U-yen, Kongpop; Brown, Ari; Hsieh, Wen-Ting; Wollack, Edward; Moseley, Samuel

    2013-01-01

    This innovation is a compact, superconducting, channelizing bandpass filter on a single-crystal (0.45 m thick) silicon substrate, which operates from 300 to 600 GHz. This device consists of four channels with center frequencies of 310, 380, 460, and 550 GHz, with approximately 50-GHz bandwidth per channel. The filter concept is inspired by the mammalian cochlea, which is a channelizing filter that covers three decades of bandwidth and 3,000 channels in a very small physical space. By using a simplified physical cochlear model, and its electrical analog of a channelizing filter covering multiple octaves bandwidth, a large number of output channels with high inter-channel isolation and high-order upper stopband response can be designed. A channelizing filter is a critical component used in spectrometer instruments that measure the intensity of light at various frequencies. This embodiment was designed for MicroSpec in order to increase the resolution of the instrument (with four channels, the resolution will be increased by a factor of four). MicroSpec is a revolutionary wafer-scale spectrometer that is intended for the SPICA (Space Infrared Telescope for Cosmology and Astrophysics) Mission. In addition to being a vital component of MicroSpec, the channelizing filter itself is a low-resolution spectrometer when integrated with only an antenna at its input, and a detector at each channel s output. During the design process for this filter, the available characteristic impedances, possible lumped element ranges, and fabrication tolerances were identified for design on a very thin silicon substrate. Iterations between full-wave and lumped-element circuit simulations were performed. Each channel s circuit was designed based on the availability of characteristic impedances and lumped element ranges. This design was based on a tabular type bandpass filter with no spurious harmonic response. Extensive electromagnetic modeling for each channel was performed. Four channels

  17. Frequency Domain Image Filtering Using CUDA

    Directory of Open Access Journals (Sweden)

    Muhammad Awais Rajput

    2014-10-01

    Full Text Available In this paper, we investigate the implementation of image filtering in frequency domain using NVIDIA?s CUDA (Compute Unified Device Architecture. In contrast to signal and image filtering in spatial domain which uses convolution operations and hence is more compute-intensive for filters having larger spatial extent, the frequency domain filtering uses FFT (Fast Fourier Transform which is much faster and significantly reduces the computational complexity of the filtering. We implement the frequency domain filtering on CPU and GPU respectively and analyze the speed-up obtained from the CUDA?s parallel processing paradigm. In order to demonstrate the efficiency of frequency domain filtering on CUDA, we implement three frequency domain filters, i.e., Butterworth, low-pass and Gaussian for processing different sizes of images on CPU and GPU respectively and perform the GPU vs. CPU benchmarks. The results presented in this paper show that the frequency domain filtering with CUDA achieves significant speed-up over the CPU processing in frequency domain with the same level of (output image quality on both the processing architectures

  18. Frequency domain image filtering using cuda

    International Nuclear Information System (INIS)

    Rajput, M.A.; Khan, U.A.

    2014-01-01

    In this paper, we investigate the implementation of image filtering in frequency domain using NVIDIA's CUDA (Compute Unified Device Architecture). In contrast to signal and image filtering in spatial domain which uses convolution operations and hence is more compute-intensive for filters having larger spatial extent, the frequency domain filtering uses FFT (Fast Fourier Transform) which is much faster and significantly reduces the computational complexity of the filtering. We implement the frequency domain filtering on CPU and GPU respectively and analyze the speed-up obtained from the CUDA's parallel processing paradigm. In order to demonstrate the efficiency of frequency domain filtering on CUDA, we implement three frequency domain filters, i.e., Butter worth, low-pass and Gaussian for processing different sizes of images on CPU and GPU respectively and perform the GPU vs. CPU benchmarks. The results presented in this paper show that the frequency domain filtering with CUDA achieves significant speed-up over the CPU processing in frequency domain with the same level of (output) image quality on both the processing architectures. (author)

  19. Fremont Tree-Well Filter

    Science.gov (United States)

    Information about the SFBWQP Fremont Tree-Well Filter Spine project, part of an EPA competitive grant program to improve SF Bay water quality focused on restoring impaired waters and enhancing aquatic resources.

  20. Social Collaborative Filtering by Trust.

    Science.gov (United States)

    Yang, Bo; Lei, Yu; Liu, Jiming; Li, Wenjie

    2017-08-01

    Recommender systems are used to accurately and actively provide users with potentially interesting information or services. Collaborative filtering is a widely adopted approach to recommendation, but sparse data and cold-start users are often barriers to providing high quality recommendations. To address such issues, we propose a novel method that works to improve the performance of collaborative filtering recommendations by integrating sparse rating data given by users and sparse social trust network among these same users. This is a model-based method that adopts matrix factorization technique that maps users into low-dimensional latent feature spaces in terms of their trust relationship, and aims to more accurately reflect the users reciprocal influence on the formation of their own opinions and to learn better preferential patterns of users for high-quality recommendations. We use four large-scale datasets to show that the proposed method performs much better, especially for cold start users, than state-of-the-art recommendation algorithms for social collaborative filtering based on trust.

  1. Method of mounting filter elements and mounting therefor

    International Nuclear Information System (INIS)

    Karelin, J.; Neumann, G.M.

    1981-01-01

    A process for the insertion and exchange of the filter elements for suspended matter is performed from the clean-air-side. During the insertion of a filter element, a plastic tube (Which encircles the circumference of the filter element and which exceeds in its length the layer thickness of the filter element several times) is tightly connected in its middle section with the side walls, which side walls form a border around the filter element; and then the open end of the plastic tube, which faces the frame, is connected by way of a tight fit with a ring, which is actually known and which surrounds the orifice of the frame into which the filter element is inserted. The filter element is connected with the frame by means of tightening devices, and the outer free end of the tube is turned inside out and around the filter element for the purpose of unhindered air passage through the filter layer, that during the exchange of the contaminated filter element, the outer open end of the tube is heat sealed. The filter element is disconnected and removed from the frame by flipping down of the tightening devices, and the tube is heat sealed in the section between the filter element and the frame, and, that during the insertion of a new filter element, a new tube is attached by way of tight fitting to the ring of the frame , which tube is at its middle section tightly connected with the filter element, and which tube is attached to the ring of the frame in an actually known by overlapping of the heat-sealed tube rest. The tube rest is pulled onto the new tube and pulled off the ring, and the filter element is tightly connected with the frame by means of the tightening devices

  2. Rotating Ceramic Water Filter Discs System for Water Filtration

    Directory of Open Access Journals (Sweden)

    Riyadh Z. Al Zubaidy

    2017-04-01

    Full Text Available This work aimed to design, construct and operate a new laboratory scale water filtration system. This system was used to examine the efficiency of two ceramic filter discs as a medium for water filtration. These filters were made from two different ceramic mixtures of local red clay, sawdust, and water. The filtration system was designed with two rotating interfered modules of these filters. Rotating these modules generates shear force between water and the surfaces of filter discs of the filtration modules that works to reduce thickness of layer of rejected materials on the filters surfaces. Each module consists of seven filtration units and each unit consists of two ceramic filter discs. The average measured hydraulic conductivity of the first module was 13.7mm/day and that for the second module was 50mm/day. Results showed that the water filtration system can be operated continuously with a constant flow rate and the filtration process was controlled by a skin thin layer of rejected materials. The ceramic water filters of both filtration modules have high removal efficiency of total suspended solids up to 100% and of turbidity up to 99.94%.

  3. Study on Water Quality of Surface Runoff and Groundwater Runoff on the Basis of Separation by a Numerical Filter

    OpenAIRE

    Kawara, Osami; Fukumoto, Kohji

    1994-01-01

    In this study we investigated the water quality of surface runoff and groundwater runoff from the basins of the Yodo River and the Asahi River based on that separated by a numerical filter. The water quality of the surface runoff is greatly different from the groundwater runoff. The tendency of concentration change in accordance with river discharges is different from each other. The water qtiality of groundwater runoff changes with river discharges clockwise in many cases. The differences of...

  4. FLOWING BILATERAL FILTER: DEFINITION AND IMPLEMENTATIONS

    Directory of Open Access Journals (Sweden)

    Maxime Moreaud

    2015-06-01

    Full Text Available The bilateral filter plays a key role in image processing applications due to its intuitive parameterization and its high quality filter result, smoothing homogeneous regions while preserving the edges of the objects. Considering the image as a topological relief, seeing pixel intensities as peaks and valleys, we introduce a way to control the tonal weighting coefficients, the flowing bilateral filter, reducing "halo" artifacts typically produced by the regular bilateral filter around a large peak surrounded by two valleys of lower values. In this paper we propose to investigate exact and approximated versions of CPU and parallel GPU (Graphical Processing Unit based implementations of the regular and flowing bilateral filter using the NVidia CUDA API. Fast implementations of these filters are important for the processing of large 3D volumes up to several GB acquired by x-ray or electron tomography.

  5. Polarization filtering in the visible wavelength range using surface plasmon resonance and a sunflower-type photonic quasi-crystal fiber

    Science.gov (United States)

    Yan, Bei; Wang, Anran; Liu, Exian; Tan, Wei; Xie, Jianlan; Ge, Rui; Liu, Jianjun

    2018-04-01

    A novel polarization filter based on a sunflower-type photonic quasi-crystal fiber (PQF) is proposed in this paper. We also discuss different methods to tune the filter wavelength. The proposed filter can efficiently produce polarized light with visible wavelengths by using the resonance between the second-order surface plasmon polariton mode and the core mode of the PQF. The filtered wavelength can be tuned between 0.55 µm and 0.68 µm by adjusting the thickness of the gold film. When the thickness of the gold film is 25.3 nm, the resonance loss in the y-polarized direction reaches 11707 dB m‑1 for a wavelength of 0.6326 µm, and the full width at half maximum is only 5 nm. Due to the flexible design and absence of both polarization coupling and polarization dispersion, this polarization filter can be used in devices that require narrow-band filtering.

  6. Optimum filter-based discrimination of neutrons and gamma rays

    International Nuclear Information System (INIS)

    Amiri, Moslem; Prenosil, Vaclav; Cvachovec, Frantisek

    2015-01-01

    An optimum filter-based method for discrimination of neutrons and gamma-rays in a mixed radiation field is presented. The existing filter-based implementations of discriminators require sample pulse responses in advance of the experiment run to build the filter coefficients, which makes them less practical. Our novel technique creates the coefficients during the experiment and improves their quality gradually. Applied to several sets of mixed neutron and photon signals obtained through different digitizers using stilbene scintillator, this approach is analyzed and its discrimination quality is measured. (authors)

  7. Experimental validation of a method characterizing bow tie filters in CT scanners using a real-time dose probe

    International Nuclear Information System (INIS)

    McKenney, Sarah E.; Nosratieh, Anita; Gelskey, Dale; Yang Kai; Huang Shinying; Chen Lin; Boone, John M.

    2011-01-01

    Purpose: Beam-shaping or ''bow tie'' (BT) filters are used to spatially modulate the x-ray beam in a CT scanner, but the conventional method of step-and-shoot measurement to characterize a beam's profile is tedious and time-consuming. The theory for characterization of bow tie relative attenuation (COBRA) method, which relies on a real-time dosimeter to address the issues of conventional measurement techniques, was previously demonstrated using computer simulations. In this study, the feasibility of the COBRA theory is further validated experimentally through the employment of a prototype real-time radiation meter and a known BT filter. Methods: The COBRA method consisted of four basic steps: (1) The probe was placed at the edge of a scanner's field of view; (2) a real-time signal train was collected as the scanner's gantry rotated with the x-ray beam on; (3) the signal train, without a BT filter, was modeled using peak values measured in the signal train of step 2; and (4) the relative attenuation of the BT filter was estimated from filtered and unfiltered data sets. The prototype probe was first verified to have an isotropic and linear response to incident x-rays. The COBRA method was then tested on a dedicated breast CT scanner with a custom-designed BT filter and compared to the conventional step-and-shoot characterization of the BT filter. Using basis decomposition of dual energy signal data, the thickness of the filter was estimated and compared to the BT filter's manufacturing specifications. The COBRA method was also demonstrated with a clinical whole body CT scanner using the body BT filter. The relative attenuation was calculated at four discrete x-ray tube potentials and used to estimate the thickness of the BT filter. Results: The prototype probe was found to have a linear and isotropic response to x-rays. The relative attenuation produced from the COBRA method fell within the error of the relative attenuation measured with the step-and-shoot method

  8. In-situ testing of HEPA filters in the nuclear Karlsruhe filter system

    International Nuclear Information System (INIS)

    Ohlmeyer, M.; Stotz, W.

    1977-01-01

    Nuclear plant operators and filter manufacturers are endeavouring to improve environmental protection by intensifying process control and/or improving filter quality. In-situ testing is an important element in these efforts since it represents a direct means of checking the success or otherwise of a particular development. The arrangements for in-situ testing should satisfy the following minimum requirements: the staff should not be exposed to risk during the test; the test method should be objective and reproducible as well as being as sensitive as possible; the test method should permit detection of individual leaks in the filter system so that they can be remedied as efficiently as possible; the test equipment should not necessitate modifications to the extract systems or plant construction; the test should be simple and capable of being carried out with a minimum of effort and equipment. GfK has developed the 'Nuclear-Karlsruhe' filter housing in accordance with these principles. This housing permits in-situ testing similar to the DIN 24184 visual oil-fog test or the DOP test. External visual checks on the general condition of the filter is also possible. A safe system of filter changing with a specially designed plastic bag attachment at an accessible height considerably increases the degree of protection of operating personnel

  9. First Study Of HEPA Filter Prototype Performance To Control The Airborne Pollution

    International Nuclear Information System (INIS)

    Soetomo; Suwarno

    2000-01-01

    This paper will report the efficiency test result of the filtration tool prototype of High Efficiency Particulate Air (HEPA filter) for low temperature, to control the airborne pollution of aerosol particle of solid and liquid. The prototype design of HEPA filter was based on the characteristic data of filter material (fibrous diameter, density, filter thickness), flow rate of air and first pressure drop. From the result of laboratory scale test, using DOP/PSL aerosol with 0,3 mum diameter and the flow rate of 3,78 m exp.3/min, was obtained filtration efficiency revolve between 89,90 and 99,94 % for the filter prototype of A, B, C, and D. the efficiency estimation of theory with filtration programme and the experiment was different amount 1 %. The value of the prototype efficiency of D filter was not far different with AAF-USA filter and its price is cheaper 30 % than the price of AAF-USA filter

  10. Portable abdomen radiography. Moving to thickness-based protocols

    International Nuclear Information System (INIS)

    Sanchez, Adrian A.; Reiser, Ingrid; Baxter, Tina; Zhang, Yue; Finkle, Joshua H.; Lu, Zheng Feng; Feinstein, Kate A.

    2018-01-01

    Default pediatric protocols on many digital radiography systems are configured based on patient age. However, age does not adequately characterize patient size, which is the principal determinant of proper imaging technique. Use of default pediatric protocols by inexperienced technologists can result in patient overexposure, inadequate image quality, or repeated examinations. To ensure diagnostic image quality at a well-managed patient radiation exposure by transitioning to thickness-based protocols for pediatric portable abdomen radiography. We aggregated patient thickness data, milliamperes (mAs), kilovoltage peak (kVp), exposure index (EI), source-to-detector distance, and grid use for all portable abdomen radiographs performed in our pediatric hospital in a database with a combination of automated and manual data collection techniques. We then analyzed the database and used it as the basis to construct thickness-based protocols with consistent image quality across varying patient thicknesses, as determined by the EI. Retrospective analysis of pediatric portable exams performed at our adult-focused hospitals demonstrated substantial variability in EI relative to our pediatric hospital. Data collection at our pediatric hospital over 4 months accumulated roughly 800 portable abdomen exams, which we used to develop a thickness-based technique chart. Through automated retrieval of data in our systems' digital radiography exposure logs and recording of patient abdomen thickness, we successfully developed thickness-based techniques for portable abdomen radiography. (orig.)

  11. Portable abdomen radiography. Moving to thickness-based protocols

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez, Adrian A.; Reiser, Ingrid; Baxter, Tina; Zhang, Yue; Finkle, Joshua H.; Lu, Zheng Feng; Feinstein, Kate A. [University of Chicago Medical Center, Department of Radiology, Chicago, IL (United States)

    2018-02-15

    Default pediatric protocols on many digital radiography systems are configured based on patient age. However, age does not adequately characterize patient size, which is the principal determinant of proper imaging technique. Use of default pediatric protocols by inexperienced technologists can result in patient overexposure, inadequate image quality, or repeated examinations. To ensure diagnostic image quality at a well-managed patient radiation exposure by transitioning to thickness-based protocols for pediatric portable abdomen radiography. We aggregated patient thickness data, milliamperes (mAs), kilovoltage peak (kVp), exposure index (EI), source-to-detector distance, and grid use for all portable abdomen radiographs performed in our pediatric hospital in a database with a combination of automated and manual data collection techniques. We then analyzed the database and used it as the basis to construct thickness-based protocols with consistent image quality across varying patient thicknesses, as determined by the EI. Retrospective analysis of pediatric portable exams performed at our adult-focused hospitals demonstrated substantial variability in EI relative to our pediatric hospital. Data collection at our pediatric hospital over 4 months accumulated roughly 800 portable abdomen exams, which we used to develop a thickness-based technique chart. Through automated retrieval of data in our systems' digital radiography exposure logs and recording of patient abdomen thickness, we successfully developed thickness-based techniques for portable abdomen radiography. (orig.)

  12. Performance of an optical filter for the XMM focal plane CCD camera EPIC

    Science.gov (United States)

    Stephan, Karl-Heinz; Reppin, C.; Hirschinger, M.; Maier, H. J.; Frischke, D.; Fuchs, Detlef; Mueller, Peter; Guertler, Peter

    1996-10-01

    We have been developing optical filters for ESA's x-ray astronomy project XMM (x-ray multi mirror mission). Specific CCDs will be used as detectors in the focal plane on board the observatory. Since these detectors are sensitive from the x-ray to the NIR (near infrared) spectral range, x-ray observations require optical filters, which combine a high transparency for photon energies in the soft x-ray region and a high opacity for UV (ultraviolet) and VIS (visible) radiation as well. With respect to the mission goal in orbit three types of flight model filters are designed having different spectral transmittance functions. We report on one of these types, a so-called 'thick' filter, which has been realized within the EQM (electrical qualification model)- phase of the project. The filter features a cut-off in the EUV (extreme ultraviolet) spectral range and suppresses radiation below 10 eV photon energy by more than 8 orders of magnitude. It has an effective aperture of 73 mm without any support structure. A 0.35 micrometer thick polypropylene carrier foil is coated with metallic films of Al and Sn. The manufacturing process, the qualification measurements and the environmental tests are described, and the resulting performance data is presented.

  13. Fabrication of dense wavelength division multiplexing filters with large useful area

    Science.gov (United States)

    Lee, Cheng-Chung; Chen, Sheng-Hui; Hsu, Jin-Cherng; Kuo, Chien-Cheng

    2006-08-01

    Dense Wavelength Division Multiplexers (DWDM), a kind of narrow band-pass filter, are extremely sensitive to the optical thickness error in each composite layer. Therefore to have a large useful coating area is extreme difficult because of the uniformity problem. To enlarge the useful coating area it is necessary to improve their design and their fabrication. In this study, we discuss how the tooling factors at different positions and for different materials are related to the optical performance of the design. 100GHz DWDM filters were fabricated by E-gun evaporation with ion-assisted deposition (IAD). To improve the coating uniformity, an analysis technique called shaping tooling factor (STF) was used to analyze the deviation of the optical thickness in different materials so as to enlarge the useful coating area. Also a technique of etching the deposited layers with oxygen ions was introduced. When the above techniques were applied in the fabrication of 100 GHz DWDM filters, the uniformity was better than +/-0.002% over an area of 72 mm in diameter and better than +/-0.0006% over 20mm in diameter.

  14. Optimization of Butterworth filter for brain SPECT imaging

    International Nuclear Information System (INIS)

    Minoshima, Satoshi; Maruno, Hirotaka; Yui, Nobuharu

    1993-01-01

    A method has been described to optimize the cutoff frequency of the Butterworth filter for brain SPECT imaging. Since a computer simulation study has demonstrated that separation between an object signal and the random noise in projection images in a spatial-frequency domain is influenced by the total number of counts, the cutoff frequency of the Butterworth filter should be optimized for individual subjects according to total counts in a study. To reveal the relationship between the optimal cutoff frequencies and total counts in brain SPECT study, we used a normal volunteer and 99m Tc hexamethyl-propyleneamine oxime (HMPAO) to obtain projection sets with different total counts. High quality images were created from a projection set with an acquisition time of 300-seconds per projection. The filter was optimized by calculating mean square errors from high quality images visually inspecting filtered reconstructed images. Dependence between total counts and optimal cutoff frequencies was clearly demonstrated in a nomogram. Using this nomogram, the optimal cutoff frequency for each study can be estimated from total counts, maximizing visual image quality. The results suggest that the cutoff frequency of Butterworth filter should be determined by referring to total counts in each study. (author)

  15. Filtered epithermal quasi-monoenergetic neutron beams at research reactor facilities

    International Nuclear Information System (INIS)

    Mansy, M.S.; Bashter, I.I.; El-Mesiry, M.S.; Habib, N.; Adib, M.

    2015-01-01

    Filtered neutron techniques were applied to produce quasi-monoenergetic neutron beams in the energy range of 1.5–133 keV at research reactors. A simulation study was performed to characterize the filter components and transmitted beam lines. The filtered beams were characterized in terms of the optimal thickness of the main and additive components. The filtered neutron beams had high purity and intensity, with low contamination from the accompanying thermal emission, fast neutrons and γ-rays. A computer code named “QMNB” was developed in the “MATLAB” programming language to perform the required calculations. - Highlights: • Quasi-monoenergetic neutron beams in energy range from (1.5–133) keV. • Interference between the resonance and potential scattering amplitudes. • Epithermal neutron beams used in BNCT

  16. A 15-pole high temperature superconductor filter for radar applications

    Science.gov (United States)

    Yu, Xiao; Xi, Weibin; Wu, Songtao

    2018-06-01

    This paper presents a compact and high first harmonic frequency resonator. The characteristics of this resonator are theoretically analyzed. A highly selective 15-pole Chebyshev high temperature superconducting ultra-high frequency narrowband filter for radar applications was fabricated by using this resonator. The filter has a center frequency of 495 MHz and a fractional bandwidth of 1%. The first harmonic frequency is more than 3.3 times the fundamental frequency. The measured filter shows excellent selectivity, better than 85 dB/1 MHz skirt slopes, and more than 85 dB of rejection at 497.5 MHz from the band edge. The filter was fabricated on a 2 inch YBCO thin film with a 0.5 mm thick MgO substrate. The experimental results are consistent with the simulations.

  17. Multispectral Detection with Metal-Dielectric Filters: An Investigation in Several Wavelength Bands with Temporal Coupled-Mode Theory

    Science.gov (United States)

    Lesmanne, Emeline; Espiau de Lamaestre, Roch; Boutami, Salim; Durantin, Cédric; Dussopt, Laurent; Badano, Giacomo

    2016-09-01

    Multispectral infrared (IR) detection is of great interest to enhance our ability to gather information from a scene. Filtering is a low-cost alternative to the complex multispectral device architectures to which the IR community has devoted much attention. Multilayer dielectric filters are standard in industry, but they require changing the thickness of at least one layer to tune the wavelength. Here, we pursue an approach based on apertures in a metallic layer of fixed thickness, in which the filtered wavelengths are selected by varying the aperture geometry. In particular, we study filters made of at least one sheet of resonating apertures in metal embedded in dielectrics. We will discuss two interesting problems that arise when one attempts to design such filters. First, metallic absorption must be taken into account. Second, the form and size of the pattern is limited by lithography. We will present some design examples and an attempt at explaining the filtering behavior based on the temporal coupled mode theory. That theory models the filter as a resonator interacting with the environment via loss channels. The transmission is solely determined by the loss rates associated with those channels. This model allows us to give a general picture of the filtering performance and compare their characteristics at different wavelength bands.

  18. E2CAV, Pavement layer thickness estimation system based on image texture operators

    Directory of Open Access Journals (Sweden)

    Brayan Barrios Arcila

    2017-01-01

    Full Text Available Context: Public roads are an essential part of economic progress in any country; they are fundamental for increasing the efficiency on transportation of goods and are a remarkable source of employment. For its part, Colombia has few statistics on the condition of its roads; according with INVIAS the state of the roads in Colombia can be classified as “Very Good” (21.1%, “Good” (34.7%, and “Regular” or “Bad” (43.46%. Thus, from the point of view of pavement rehabilitation, it is worth securing the quality of those roads classified as “Regular” or “Bad”. Objective: In this paper we propose a system to estimate the thickness of the pavement layer using image segmentation methods. The pavement thickness is currently estimated using radars of terrestrial penetration, extraction of cores or making pips; and it is part of structural parameters in the systems of evaluation of pavement. Method: The proposed system is composed of a vertical movement control unit, which introduces a video scope into a small hole in the pavement, then the images are obtained and unified in a laptop. Finally, this mosaic is processed through texture operators to estimate the thickness of the pavement. Users can select between the Otsu method and Gabor filters to process the image data. Results: The results include laboratory and field tests; these tests show errors of 5.03% and 11.3%, respectively, in the thickness of the pavement. Conclusion: The proposed system is an attractive option for local estimation of pavement thickness, with minimal structural damage and less impact on mobility and number of operators.

  19. Helical CT for lung-cancer screening. 3. Fundamental study for ultra-low-dose CT by application of small tube current and filter

    International Nuclear Information System (INIS)

    Itoh, Shigeki; Koyama, Shuji; Tusaka, Masatoshi; Maekoshi, Hisashi; Satake, Hiroko; Ishigaki, Takeo.

    1996-01-01

    In order to develop ultra-low-dose helical CT for lung cancer screening, the effect of reduction of the tube current to 20 mA and application of a 10 mm thick aluminium filter upon radiation dose and image quality was evaluated with a phantom. Exposure dose at the center of a gantry and absorbed dose at the center of an acrylic phantom at 20 mA with the filter were 15% and 29% of the dose at 50 mA without the filter, respectively. For reduction of absorbed dose, reduction of the tube current was more useful than application of the filter. Image noise at 20 mA with the filter was double that at 50 mA without the filter. Neither reduction of the tube current nor application of the filter changed full width at half maximum on section sensitivity of the Z-axis. Although reduction of the tube current did not affect the difference in CT values between an acrylic sphere and styroform, application of the filter caused a reduction of 4.5% in the difference in CT values. Neither reduction of the tube current nor application of the filter affected the contrast resolution of the high-contrast phantom; however, that of the low-contrast phantom deteriorated. Although improvement of the filter and evaluation of clinical images are necessary, reduction of the tube current to 20 mA and application of the aluminium filter appear to be a promising method for ultra-low-dose helical CT of the lung. (author)

  20. Iterated unscented Kalman filter for phase unwrapping of interferometric fringes.

    Science.gov (United States)

    Xie, Xianming

    2016-08-22

    A fresh phase unwrapping algorithm based on iterated unscented Kalman filter is proposed to estimate unambiguous unwrapped phase of interferometric fringes. This method is the result of combining an iterated unscented Kalman filter with a robust phase gradient estimator based on amended matrix pencil model, and an efficient quality-guided strategy based on heap sort. The iterated unscented Kalman filter that is one of the most robust methods under the Bayesian theorem frame in non-linear signal processing so far, is applied to perform simultaneously noise suppression and phase unwrapping of interferometric fringes for the first time, which can simplify the complexity and the difficulty of pre-filtering procedure followed by phase unwrapping procedure, and even can remove the pre-filtering procedure. The robust phase gradient estimator is used to efficiently and accurately obtain phase gradient information from interferometric fringes, which is needed for the iterated unscented Kalman filtering phase unwrapping model. The efficient quality-guided strategy is able to ensure that the proposed method fast unwraps wrapped pixels along the path from the high-quality area to the low-quality area of wrapped phase images, which can greatly improve the efficiency of phase unwrapping. Results obtained from synthetic data and real data show that the proposed method can obtain better solutions with an acceptable time consumption, with respect to some of the most used algorithms.

  1. Development of Real Time Implementation of 5/5 Rule based Fuzzy Logic Controller Shunt Active Power Filter for Power Quality Improvement

    Science.gov (United States)

    Puhan, Pratap Sekhar; Ray, Pravat Kumar; Panda, Gayadhar

    2016-12-01

    This paper presents the effectiveness of 5/5 Fuzzy rule implementation in Fuzzy Logic Controller conjunction with indirect control technique to enhance the power quality in single phase system, An indirect current controller in conjunction with Fuzzy Logic Controller is applied to the proposed shunt active power filter to estimate the peak reference current and capacitor voltage. Current Controller based pulse width modulation (CCPWM) is used to generate the switching signals of voltage source inverter. Various simulation results are presented to verify the good behaviour of the Shunt active Power Filter (SAPF) with proposed two levels Hysteresis Current Controller (HCC). For verification of Shunt Active Power Filter in real time, the proposed control algorithm has been implemented in laboratory developed setup in dSPACE platform.

  2. The effectiveness of the use of filter on the tilapia growth performance, number of Nitrosomonas sp., and water quality in aquaponics systems

    OpenAIRE

    Yuli Andriani; , Zahidah; Yayat Dhahiyat; Ujang Subhan; Irfan Zidni; Rusky Intan Pratama; Nadia Purnamasari Gumay

    2018-01-01

    ABSTRACT This study aims to determine the most effective type of living filter media for the bacteria Nitrosomonas sp. in order to improve water quality in aquaponics systems. The method used in this study was completely randomized design, consisting of five treatments and each was repeated three times. The treatments were: A (without addition of filter media), B (addition of palm fibers, silica sand, and activated carbon), C (addition of palm fibers, silica sand, gravel, and activated carbon...

  3. Reduction of radiation exposure while maintaining high-quality fluoroscopic images during interventional cardiology using novel x-ray tube technology with extra beam filtering.

    Science.gov (United States)

    den Boer, A; de Feyter, P J; Hummel, W A; Keane, D; Roelandt, J R

    1994-06-01

    Radiographic technology plays an integral role in interventional cardiology. The number of interventions continues to increase, and the associated radiation exposure to patients and personnel is of major concern. This study was undertaken to determine whether a newly developed x-ray tube deploying grid-switched pulsed fluoroscopy and extra beam filtering can achieve a reduction in radiation exposure while maintaining fluoroscopic images of high quality. Three fluoroscopic techniques were compared: continuous fluoroscopy, pulsed fluoroscopy, and a newly developed high-output pulsed fluoroscopy with extra filtering. To ascertain differences in the quality of images and to determine differences in patient entrance and investigator radiation exposure, the radiated volume curve was measured to determine the required high voltage levels (kVpeak) for different object sizes for each fluoroscopic mode. The fluoroscopic data of 124 patient procedures were combined. The data were analyzed for radiographic projections, image intensifier field size, and x-ray tube kilovoltage levels (kVpeak). On the basis of this analysis, a reference procedure was constructed. The reference procedure was tested on a phantom or dummy patient by all three fluoroscopic modes. The phantom was so designed that the kilovoltage requirements for each projection were comparable to those needed for the average patient. Radiation exposure of the operator and patient was measured during each mode. The patient entrance dose was measured in air, and the operator dose was measured by 18 dosimeters on a dummy operator. Pulsed compared with continuous fluoroscopy could be performed with improved image quality at lower kilovoltages. The patient entrance dose was reduced by 21% and the operator dose by 54%. High-output pulsed fluoroscopy with extra beam filtering compared with continuous fluoroscopy improved the image quality, lowered the kilovoltage requirements, and reduced the patient entrance dose by 55% and

  4. Alternating minimisation for glottal inverse filtering

    International Nuclear Information System (INIS)

    Bleyer, Ismael Rodrigo; Lybeck, Lasse; Auvinen, Harri; Siltanen, Samuli; Airaksinen, Manu; Alku, Paavo

    2017-01-01

    A new method is proposed for solving the glottal inverse filtering (GIF) problem. The goal of GIF is to separate an acoustical speech signal into two parts: the glottal airflow excitation and the vocal tract filter. To recover such information one has to deal with a blind deconvolution problem. This ill-posed inverse problem is solved under a deterministic setting, considering unknowns on both sides of the underlying operator equation. A stable reconstruction is obtained using a double regularization strategy, alternating between fixing either the glottal source signal or the vocal tract filter. This enables not only splitting the nonlinear and nonconvex problem into two linear and convex problems, but also allows the use of the best parameters and constraints to recover each variable at a time. This new technique, called alternating minimization glottal inverse filtering (AM-GIF), is compared with two other approaches: Markov chain Monte Carlo glottal inverse filtering (MCMC-GIF), and iterative adaptive inverse filtering (IAIF), using synthetic speech signals. The recent MCMC-GIF has good reconstruction quality but high computational cost. The state-of-the-art IAIF method is computationally fast but its accuracy deteriorates, particularly for speech signals of high fundamental frequency ( F 0). The results show the competitive performance of the new method: With high F 0, the reconstruction quality is better than that of IAIF and close to MCMC-GIF while reducing the computational complexity by two orders of magnitude. (paper)

  5. SU-D-206-06: Task-Specific Optimization of Scintillator Thickness for CMOS-Detector Based Cone-Beam Breast CT

    Energy Technology Data Exchange (ETDEWEB)

    Vedantham, S; Shrestha, S; Shi, L; Vijayaraghavan, G; Karellas, A [University of Massachusetts Medical School, Worcester, MA (United States)

    2016-06-15

    Purpose: To optimize the cesium iodide (CsI:Tl) scintillator thickness in a complimentary metal-oxide semiconductor (CMOS)-based detector for use in dedicated cone-beam breast CT. Methods: The imaging task considered was the detection of a microcalcification cluster comprising six 220µm diameter calcium carbonate spheres, arranged in the form of a regular pentagon with 2 mm spacing on its sides and a central calcification, similar to that in ACR-recommended mammography accreditation phantom, at a mean glandular dose of 4.5 mGy. Generalized parallel-cascades based linear systems analysis was used to determine Fourier-domain image quality metrics in reconstructed object space, from which the detectability index inclusive of anatomical noise was determined for a non-prewhitening numerical observer. For 300 projections over 2π, magnification-associated focal-spot blur, Monte Carlo derived x-ray scatter, K-fluorescent emission and reabsorption within CsI:Tl, CsI:Tl quantum efficiency and optical blur, fiberoptic plate transmission efficiency and blur, CMOS quantum efficiency, pixel aperture function and additive noise, and filtered back-projection to isotropic 105µm voxel pitch with bilinear interpolation were modeled. Imaging geometry of a clinical prototype breast CT system, a 60 kV Cu/Al filtered x-ray spectrum from 0.3 mm focal spot incident on a 14 cm diameter semi-ellipsoidal breast were used to determine the detectability index for 300–600 µm thick (75µm increments) CsI:Tl. The CsI:Tl thickness that maximized the detectability index was considered optimal. Results: The limiting resolution (10% modulation transfer function, MTF) progressively decreased with increasing CsI:Tl thickness. The zero-frequency detective quantum efficiency, DQE(0), in projection space increased with increasing CsI:Tl thickness. The maximum detectability index was achieved with 525µm thick CsI:Tl scintillator. Reduced MTF at mid-to-high frequencies for 600µm thick CsI:Tl lowered

  6. Design of a thin-plate based tunable high-quality narrow passband filter for elastic transverse waves propagate in metals

    Science.gov (United States)

    Zhang, J.; Zeng, L. H.; Hu, C. L.; Yan, W. S.; Pennec, Yan; Hu, N.

    2018-03-01

    For the elastic SV (transverse) waves in metals, a high-quality narrow passband filter that consists of aligned parallel thin plates with small gaps is designed. In order to obtain a good performance, the thin plates should be constituted by materials with a smaller mass density and Young's modulus, such as polymethylmethacrylate (PMMA), compared to the embedded materials in which the elastic SV waves propagate. Both the theoretical model and the full numerical simulation show that the transmission spectrum of the designed filter demonstrates several peaks with flawless transmission within 0 KHz ˜20 KHz frequency range. The peaks can be readily tuned by manipulating the geometrical parameters of the plates. Therefore, the current design works well for both low and high frequencies with a controllable size. Even for low frequencies on the order of kilohertz, the size of this filter can be still limited to the order of centimeters, which significantly benefits the real applications. The investigation also finds that the same filter is valid when using different metals and the reason behind this is explained theoretically. Additionally, the effect of bonding conditions of interfaces between thin plates and the base material is investigated using a spring model.

  7. Tunable M-channel filter based on Thue-Morse heterostructures containing meta materials

    Directory of Open Access Journals (Sweden)

    H Pashaei Adl

    2015-01-01

    Full Text Available In this paper the tunable M-channel filters based on Thue-Morse heterostructures consisting of single -negative materials has been studied. The results showed that the number of resonance modes inside the zero- gap increases as the number of heterogenous interface, M, increases. The number of resonance modes inside the zero- gap is equal to that of heterogenous interface M, and it can be used as M channels filter. This result provides a feasible method to adjust the channel number of multiple-channel filters. When losses are involved, the results showed that the electric fields of the resonance modes decay largely with the increase of the number of heterogenous interface and damping factors. Besides, the relationship between the quality factor of multiple-channel filters and the number of heterogenous interface M is linear, and the quality factor of multiple-channel filters decreases with the increase of the damping factor. These results provide feasible methods to adjust the quality factor of multiple-channel filters

  8. Optimal Performance Simulation of a Metal Fiber Filter for Capturing Radioactive Aerosols

    International Nuclear Information System (INIS)

    Lee, Seung Uk; Lee, Chan Hyun; Park, Min Chan; Lee, Jaek Eun

    2016-01-01

    In this study, the metal fiber filter used for removing radioactive aerosol is systematically dissected and studied in order to figure out the optimal design which can be applied to the actual operation conditions in nuclear heating, ventilation and air conditioning (HVAC) systems for particle collection. In order to derive the optimal design for metal fiber HEPA filter, a numerical model is developed and its results are compared to experimental data to test reliability. Moreover, sensitivity analysis is performed using important parameters to determine which parameters have large influence on the filter performance. Using the model developed in this study, optimal design parameters for pleated metal fiber filters are derived which include fiber diameter less than 4 μm, solidity larger than 0.2, filter thickness larger than 1 mm, and face velocity lower than 5 cm/s. With these conditions, the metal filter qualified for the HEPA filter standard which specified 99.97% efficiency in the 0.3 μm particle size range.

  9. Analysis and experimental evaluation of shunt active power filter for power quality improvement based on predictive direct power control.

    Science.gov (United States)

    Aissa, Oualid; Moulahoum, Samir; Colak, Ilhami; Babes, Badreddine; Kabache, Nadir

    2017-10-12

    This paper discusses the use of the concept of classical and predictive direct power control for shunt active power filter function. These strategies are used to improve the active power filter performance by compensation of the reactive power and the elimination of the harmonic currents drawn by non-linear loads. A theoretical analysis followed by a simulation using MATLAB/Simulink software for the studied techniques has been established. Moreover, two test benches have been carried out using the dSPACE card 1104 for the classic and predictive DPC control to evaluate the studied methods in real time. Obtained results are presented and compared in this paper to confirm the superiority of the predictive technique. To overcome the pollution problems caused by the consumption of fossil fuels, renewable energies are the alternatives recommended to ensure green energy. In the same context, the tested predictive filter can easily be supplied by a renewable energy source that will give its impact to enhance the power quality.

  10. Clinical effectiveness, quality of life and cost-effectiveness of Flaminal® versus Flamazine® in the treatment of partial thickness burns: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Rashaan, Zjir M; Krijnen, Pieta; van den Akker-van Marle, M Elske; van Baar, Margriet E; Vloemans, Adrianus F P; Dokter, Jan; Tempelman, Fenike R H; van der Vlies, Cees H; Breederveld, Roelf S

    2016-03-05

    Partial thickness burns are painful, difficult to manage and can have a negative effect on quality of life through scarring, permanent disfigurement and loss of function. The aim of burn treatment in partial thickness burns is to save lives, stimulate wound healing by creating an optimumly moist wound environment, to have debriding and analgesic effects, protect the wound from infection and be convenient for the patient and caregivers. However, there is no consensus on the optimal treatment of partial thickness wounds. Flaminal® and Flamazine® are two standard treatment options that provide the above mentioned properties in burn treatment. Nevertheless, no randomized controlled study has yet compared these two common treatment modalities in partial thickness burns. Thus, the aim of this study is to evaluate the clinical effectiveness, quality of life and cost-effectiveness of Flaminal® versus Flamazine® in the treatment of partial thickness burns. In this two-arm open multi-center randomized controlled trial, 90 patients will be randomized between Flaminal® and Flamazine® and followed for 12 months. The study population will consist of competent or temporarily non-competent (because of sedation and/or intubation) patients, 18 years of age or older, with acute partial thickness burns and a total body surface area (TBSA) of less than 30 %. The main study outcome is time to complete re-epithelialization (greater than 95 %). Secondary outcome measures include need for grafting, wound colonization/infection, number of dressing changes, pain and anxiety, scar formation, health-related quality of life (HRQoL), and costs. This study will contribute to the optimal treatment of patients with partial thickness burn wounds and will provide evidence on the (cost-)effectiveness and quality of life of Flaminal® versus Flamazine® in the treatment of partial thickness burns. Netherlands Trial Register NTR4486 , registered on 2 April 2014.

  11. Pyrolytic Graphite as a Selective Neutron Filter

    International Nuclear Information System (INIS)

    Adib, M.; Habib, N.; Fathalla, M.

    2006-01-01

    The transmission of neutrons through pyrolytic graphite (PG) crystals, set at different angles with respect to incident beam, were calculated using an additive formula. A computer program HOPG was developed to provide the required calculation. An overall agreement between the calculated neutron transmissions through a slab of 1,85 mm thick PG crystal with an angular spread of c-axes of 0,4 degree, set at different angles to the incident beam, and the available experimental ones in the wavelength range from (0,02 to 1,4) nm were obtained. A feasibility study for use of PG crystal as an efficient second-order neutron filter is detailed in terms of crystal thickness, angular spread of c-axes and its operation with respect to the neutron beam. It was shown that a PG crystal with an angular spread of c-axes and its orientation with respect to the neutron beam. It was shown that a PG crystal with an angular spread of 0,8 degree is sufficient for optimum scattering of second-order neutrons in the wavelength band (0,384-0,183) nm, by adjusting the filter in an appropriate orientation

  12. Buffers and vegetative filter strips

    Science.gov (United States)

    Matthew J. Helmers; Thomas M. Isenhart; Michael G. Dosskey; Seth M. Dabney

    2008-01-01

    This chapter describes the use of buffers and vegetative filter strips relative to water quality. In particular, we primarily discuss the herbaceous components of the following NRCS Conservation Practice Standards.

  13. Low-loss interference filter arrays made by plasma-assisted reactive magnetron sputtering (PARMS) for high-performance multispectral imaging

    Science.gov (United States)

    Broßmann, Jan; Best, Thorsten; Bauer, Thomas; Jakobs, Stefan; Eisenhammer, Thomas

    2016-10-01

    Optical remote sensing of the earth from air and space typically utilizes several channels in the visible and near infrared spectrum. Thin-film optical interference filters, mostly of narrow bandpass type, are applied to select these channels. The filters are arranged in filter wheels, arrays of discrete stripe filters mounted in frames, or patterned arrays on a monolithic substrate. Such multi-channel filter assemblies can be mounted close to the detector, which allows a compact and lightweight camera design. Recent progress in image resolution and sensor sensitivity requires improvements of the optical filter performance. Higher demands placed on blocking in the UV and NIR and in between the spectral channels, in-band transmission and filter edge steepness as well as scattering lead to more complex filter coatings with thicknesses in the range of 10 - 25μm. Technological limits of the conventionally used ion-assisted evaporation process (IAD) can be overcome only by more precise and higher-energetic coating technologies like plasma-assisted reactive magnetron sputtering (PARMS) in combination with optical broadband monitoring. Optics Balzers has developed a photolithographic patterning process for coating thicknesses up to 15μm that is fully compatible with the advanced PARMS coating technology. This provides the possibility of depositing multiple complex high-performance filters on a monolithic substrate. We present an overview of the performance of recently developed filters with improved spectral performance designed for both monolithic filter-arrays and stripe filters mounted in frames. The pros and cons as well as the resulting limits of the filter designs for both configurations are discussed.

  14. Study on the Metal Fiber Filter Modeling for Capturing Radioactive Aerosol

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seunguk; Lee, Chanhyun; Park, Minchan; Lee, Jaekeun [EcoEnergy Research Institute, Busan (Korea, Republic of)

    2015-05-15

    The components of air cleaning system are demisters to remove entrained moisture, pre-filters to remove the bulk of the particulate matter, high efficiency particulate air (HEPA) filters, iodine absorbers(generally, activated carbon) and HEPA filters after the absorbers for redundancy and collection of carbon fines. The HEPA filters are most important components to prevent radioactive aerosols from being released to control room and adjacent environment. The Conventional HEPA filter has pleated media for low pressure drop. Consequently, the filters must provide high collection efficiency as well as low pressure drop. Unfortunately, conventional HEPA filters are made of glass fiber and polyester, and pose disposal issues since they cannot be recycled. In fact, 31,055 HEPA filters used in nuclear facilities in the U.S are annually disposed. The Analyses at face velocities 1cm/s and 10cm/s are also carried out, and they also show R2 value of 0.995. However, since official HEPA filter standards are established at face velocity of 5cm/s, this value will be used in further analysis. From the comparative studies carried out at different filter thickness and face velocities, a good correlation is found between the model and the experiment.

  15. Effect of laser incidence angle on cut quality of 4 mm thick stainless steel sheet using fiber laser

    Science.gov (United States)

    Mullick, Suvradip; Agrawal, Arpit Kumar; Nath, Ashish Kumar

    2016-07-01

    Fiber laser has potential to outperform the more traditionally used CO2 lasers in sheet metal cutting applications due to its higher efficiency, better beam quality, reliability and ease of beam delivery through optical fiber. It has been however, reported that the higher focusability and shorter wavelength are advantageous for cutting thin metal sheets up to about 2 mm only. Better focasability results in narrower kerf-width, which leads to an earlier flow separation in the flow of assist gas within the kerf, resulting in uncontrolled material removal and poor cut quality. However, the advarse effect of tight focusability can be taken care by shifting the focal point position towards the bottom surface of work-piece, which results in a wider kerf size. This results in a more stable flow within the kerf for a longer depth, which improves the cut quality. It has also been reported that fiber laser has an unfavourable angle of incidence during cutting of thick sections, resulting in poor absorption at the metal surface. Therefore, the effect of laser incidence angle, along with other process parameters, viz. cutting speed and assist gas pressure on the cut quality of 4 mm thick steel sheet has been investigated. The change in laser incidence angle has been incorporated by inclining the beam towards and away from the cut front, and the quality factors are taken as the ratio of kerf width and the striation depth. Besides the absorption of laser radiation, beam inclination is also expected to influence the gas flow characteristics inside the kerf, shear force phenomena on the molten pool, laser beam coupling and laser power distribution at the inclined cut surface. Design of experiment has been used by implementing response surface methodology (RSM) to study the parametric dependence of cut quality, as well as to find out the optimum cut quality. An improvement in quality has been observed for both the inclination due to the combined effect of multiple phenomena.

  16. Full color organic light-emitting devices with microcavity structure and color filter.

    Science.gov (United States)

    Zhang, Weiwei; Liu, Hongyu; Sun, Runguang

    2009-05-11

    This letter demonstrated the fabrication of the full color passive matrix organic light-emitting devices based on the combination of the microcavity structure, color filter and a common white polymeric OLED. In the microcavity structure, patterned ITO terraces with different thickness were used as the anode as well as cavity spacer. The primary color emitting peaks were originally generated by the microcavity and then the second resonance peak was absorbed by the color filter.

  17. Size filtering effect in vertical stacks of In(Ga)As/GaAs self-assembled quantum rings

    International Nuclear Information System (INIS)

    Ouerghui, W.; Melliti, A.; Maaref, M.A.; Martinez-Pastor, J.; Gomis, J.; Granados, D.; Garcia, J.M.

    2006-01-01

    We present a systematic study of closely In(Ga)As/InAs quantum rings (QRs) grown by molecular beam epitaxy (MBE). Photoluminescence (PL) experiments show a strong filtering effect in the ring being stacked and simultaneous linewidth narrowing for the appropriate layer thickness (thinner thickness). If the spacer thickness is further reduced, a strong coupling between the nanostructures is produced and the signal shifts to low energy

  18. Quality evaluation of no-reference MR images using multidirectional filters and image statistics.

    Science.gov (United States)

    Jang, Jinseong; Bang, Kihun; Jang, Hanbyol; Hwang, Dosik

    2018-09-01

    This study aimed to develop a fully automatic, no-reference image-quality assessment (IQA) method for MR images. New quality-aware features were obtained by applying multidirectional filters to MR images and examining the feature statistics. A histogram of these features was then fitted to a generalized Gaussian distribution function for which the shape parameters yielded different values depending on the type of distortion in the MR image. Standard feature statistics were established through a training process based on high-quality MR images without distortion. Subsequently, the feature statistics of a test MR image were calculated and compared with the standards. The quality score was calculated as the difference between the shape parameters of the test image and the undistorted standard images. The proposed IQA method showed a >0.99 correlation with the conventional full-reference assessment methods; accordingly, this proposed method yielded the best performance among no-reference IQA methods for images containing six types of synthetic, MR-specific distortions. In addition, for authentically distorted images, the proposed method yielded the highest correlation with subjective assessments by human observers, thus demonstrating its superior performance over other no-reference IQAs. Our proposed IQA was designed to consider MR-specific features and outperformed other no-reference IQAs designed mainly for photographic images. Magn Reson Med 80:914-924, 2018. © 2018 International Society for Magnetic Resonance in Medicine. © 2018 International Society for Magnetic Resonance in Medicine.

  19. Treatment of slaughter wastewater by coagulation sedimentation-anaerobic biological filter and biological contact oxidation process

    Science.gov (United States)

    Sun, M.; Yu, P. F.; Fu, J. X.; Ji, X. Q.; Jiang, T.

    2017-08-01

    The optimal process parameters and conditions for the treatment of slaughterhouse wastewater by coagulation sedimentation-AF - biological contact oxidation process were studied to solve the problem of high concentration organic wastewater treatment in the production of small and medium sized slaughter plants. The suitable water temperature and the optimum reaction time are determined by the experiment of precipitation to study the effect of filtration rate and reflux ratio on COD and SS in anaerobic biological filter and the effect of biofilm thickness and gas water ratio on NH3-N and COD in biological contact oxidation tank, and results show that the optimum temperature is 16-24°C, reaction time is 20 min in coagulating sedimentation, the optimum filtration rate is 0.6 m/h, and the optimum reflux ratio is 300% in anaerobic biological filter reactor. The most suitable biological film thickness range of 1.8-2.2 mm and the most suitable gas water ratio is 12:1-14:1 in biological contact oxidation pool. In the coupling process of continuous operation for 80 days, the average effluent’s mass concentrations of COD, TP and TN were 15.57 mg/L, 40 mg/L and 0.63 mg/L, the average removal rates were 98.93%, 86.10%, 88.95%, respectively. The coupling process has stable operation effect and good effluent quality, and is suitable for the industrial application.

  20. Review of Department of Energy HEPA filter test activities

    International Nuclear Information System (INIS)

    McIntyre, J.A.

    1993-01-01

    Filter Test Facilities (FTFs) and the FTF Technical Support Group (TSG) continue to provide services to the Department of Energy (DOE). Additional tasks relating to the HEPA filter cycle have been added to the TSG. The tasks include the quality assessment review for the in-place testing of HEPA filters at DOE sites and the formation of an in-place testing standards writing group. Summary of ongoing FTFs and TSG activities for FY 1990-FY 1992 including the technical input for implementation of the High Flow Alternative Test System (HFATS), update of the DOE Standards, the status of the quality assessment review and in-place testing standards writing group are discussed

  1. A study of compressed breast thickness at Hirosaki University Hospital

    International Nuclear Information System (INIS)

    Kon, Masanori; Osanai, Tsunemi; Ootani, Yuhiko; Sugawara, Kaoru; Abe, Katsumi

    2000-01-01

    Evaluation of image quality and medical exposure dose is very important in mammography. However, the standard compressed breast thickness of Japanese women is uncertain. Authors therefore analyzed compressed breast thickness on bilateral cephalocaudal and mediolateral oblique radiographs of 3445 women who underwent mammography between June 5, 1989 and December 7, 1998. The total average compressed breast thickness was about 10 mm less than the thickness of the American College of Radiography (ACR) standard mammographic accreditation phantom. It therefore appears necessary to establish a Japanese standard for the phantom to evaluate image quality and medical exposure dose accurately in Japanese women. (K.H.)

  2. Tin-filter enhanced dual-energy-CT: image quality and accuracy of CT numbers in virtual noncontrast imaging.

    Science.gov (United States)

    Kaufmann, Sascha; Sauter, Alexander; Spira, Daniel; Gatidis, Sergios; Ketelsen, Dominik; Heuschmid, Martin; Claussen, Claus D; Thomas, Christoph

    2013-05-01

    To measure and compare the objective image quality of true noncontrast (TNC) images with virtual noncontrast (VNC) images acquired by tin-filter-enhanced, dual-source, dual-energy computed tomography (DECT) of upper abdomen. Sixty-three patients received unenhanced abdominal CT and enhanced abdominal DECT (100/140 kV with tin filter) in portal-venous phase. VNC images were calculated from the DECT datasets using commercially available software. The mean attenuation of relevant tissues and image quality were compared between the TNC and VNC images. Image quality was rated objectively by measuring image noise and the sharpness of object edges using custom-designed software. Measurements were compared using Student two-tailed t-test. Correlation coefficients for tissue attenuation measurements between TNC and VNC were calculated and the relative deviations were illustrated using Bland-Altman plots. Mean attenuation differences between TNC and VNC (HUTNC - HUVNC) image sets were as follows: right liver lobe -4.94 Hounsfield units (HU), left liver lobe -3.29 HU, vena cava -2.19 HU, spleen -7.46 HU, pancreas 1.29 HU, fat -11.14 HU, aorta 1.29 HU, bone marrow 36.83 HU (all P VNC and TNC series were observed for liver, vena portae, kidneys, pancreas, muscle and bone marrow (Pearson's correlation coefficient ≥0.75). Mean image noise was significantly higher in TNC images (P VNC and TNC images (P = .19). The Hounsfield units in VNC images closely resemble TNC images in the majority of the organs of the upper abdomen (kidneys, liver, pancreas). In spleen and fat, Hounsfield numbers in VNC images are tend to be higher than in TNC images. VNC images show a low image noise and satisfactory edge sharpness. Other criteria of image quality and the depiction of certain lesions need to be evaluated additionally. Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.

  3. Design of a thin-plate based tunable high-quality narrow passband filter for elastic transverse waves propagate in metals

    Directory of Open Access Journals (Sweden)

    J. Zhang

    2018-03-01

    Full Text Available For the elastic SV (transverse waves in metals, a high-quality narrow passband filter that consists of aligned parallel thin plates with small gaps is designed. In order to obtain a good performance, the thin plates should be constituted by materials with a smaller mass density and Young’s modulus, such as polymethylmethacrylate (PMMA, compared to the embedded materials in which the elastic SV waves propagate. Both the theoretical model and the full numerical simulation show that the transmission spectrum of the designed filter demonstrates several peaks with flawless transmission within 0 KHz ∼20 KHz frequency range. The peaks can be readily tuned by manipulating the geometrical parameters of the plates. Therefore, the current design works well for both low and high frequencies with a controllable size. Even for low frequencies on the order of kilohertz, the size of this filter can be still limited to the order of centimeters, which significantly benefits the real applications. The investigation also finds that the same filter is valid when using different metals and the reason behind this is explained theoretically. Additionally, the effect of bonding conditions of interfaces between thin plates and the base material is investigated using a spring model.

  4. MEASUREMENT OF RNFL THICKNESS USING OCT IMAGES FOR GLAUCOMA DETECTION

    Directory of Open Access Journals (Sweden)

    Dhivyabharathi

    2013-08-01

    Full Text Available The thickness of retinal nerve fiber layer (RNFL is one of the pompous parameters for assessing the disease, Glaucoma. A substantial amount of vision can be lost before the patient becomes aware of any defect. Optical Coherence Tomography (OCT provides enhanced depth and clarity of viewing tissues with high resolution compared with other medical imaging devices. It examines the living tissue non-invasively. This paper presents an automatic method to find the thickness of RNFL using OCT images. The proposed algorithm first extracts all the layers present in the OCT image by texture segmentation using Gabor filter method and an algorithm is then developed to segment the RNFL. The thickness measurement of RNFL is automatically displayed based on pixel calculation. The calculated thickness values are compared with the original values obtained from hospital. The result shows that the proposed algorithm is efficient in segmenting the region of interest without manual intervention. The effectiveness of the proposed method is proved statistically by the performance analysis.

  5. Polymer filters for ultraviolet-excited integrated fluorescence sensing

    International Nuclear Information System (INIS)

    Dandin, Marc; Abshire, Pamela; Smela, Elisabeth

    2012-01-01

    Optical filters for blocking ultraviolet (UV) light were fabricated by doping various polymer hosts with a UV absorbing chromophore. The polymers were polydimethylsiloxane (PDMS), a silicone elastomer frequently used in microfluidics, SU-8, a photopatternable epoxy, and Humiseal 1B66, an acrylic coating used for moisture protection of integrated circuits. The chromophore was 2-(2′-hydroxy-5′-methylphenyl) benzotriazole (BTA), which has a high extinction coefficient between 300 nm and 400 nm. We demonstrate filters 5 µm thick that exhibit high ultraviolet rejection (nearly −40 dB at 342 nm) yet pass visible light (near 0 dB above 400 nm), making them ideal for ultraviolet-excited fluorescence sensing within microsystems. The absorbance of the BTA depended on the host polymer. These filters are promising for integrated fluorescence spectroscopy in bioanalytical platforms because they can be patterned by dry etching, molding or exposure to ultraviolet light. (paper)

  6. Effect of rib fat thickness on the quality of aged meat from Nellore young bulls

    OpenAIRE

    Dallantonia,Erick Escobar; Lage,Josiane Fonseca; Simonetti,Laís Regina; Vito,Elias San; Delevatti,Lutti Maneck; Berchielli,Telma Teresinha

    2015-01-01

    This trial aimed to evaluate the quality of aged beef from Nellore young bulls under two yield grade (YG). Fourteen animals with approximately 450 ± 30 kg body weight were evaluated for backfat thickness (BFT) at the beginning of the experimental period. Seven animals had BFT of 0-3 mm and seven animals, 3.1-6 mm. Two groups were formed at the end of the experiment: animals finished with 3-6 mm BFT (seven animals) and animals finished with 6.1 to 10 mm BFT (seven animals). Every 28 days, we e...

  7. Prediction of the ledge thickness inside a high-temperature metallurgical reactor using a virtual sensor

    International Nuclear Information System (INIS)

    LeBreux, Marc; Désilets, Martin; Lacroix, Marcel

    2012-01-01

    A non-intrusive inverse heat transfer procedure for predicting the time-varying thickness of the phase-change ledge on the inner surface of the walls of a high-temperature metallurgical reactor is presented. An extended Kalman filter with augmented state is coupled with a nonlinear state-space model of the reactor in order to estimate on-line the position of the phase front. The data are collected by a heat flux sensor located inside or outside of the reactor wall. This non-intrusive method can be seen as a virtual sensor which is defined as the combination of an estimation algorithm with measurements for the estimation of 'hard to measure' on-line process variables. The inverse prediction of the ledge thickness with the virtual sensor is thoroughly tested for typical operating conditions that prevail inside an industrial facility. Due to the fact that the melting/solidification process inside the reactor is highly nonlinear, results show that the accuracy of the state-space identification and the virtual sensor estimation is far superior when a nonlinear state-space model and the extended Kalman filter are employed, as opposed to a linear state-space model and the classic Kalman filter. In the former, it is shown that the discrepancy between the exact and the estimated ledge thickness remains smaller than 10% at all times.

  8. A regularization of the Burgers equation using a filtered convective velocity

    International Nuclear Information System (INIS)

    Norgard, Greg; Mohseni, Kamran

    2008-01-01

    This paper examines the properties of a regularization of the Burgers equation in one and multiple dimensions using a filtered convective velocity, which we have dubbed as the convectively filtered Burgers (CFB) equation. A physical motivation behind the filtering technique is presented. An existence and uniqueness theorem for multiple dimensions and a general class of filters is proven. Multiple invariants of motion are found for the CFB equation which are shown to be shared with the viscous and inviscid Burgers equations. Traveling wave solutions are found for a general class of filters and are shown to converge to weak solutions of the inviscid Burgers equation with the correct wave speed. Numerical simulations are conducted in 1D and 2D cases where the shock behavior, shock thickness and kinetic energy decay are examined. Energy spectra are also examined and are shown to be related to the smoothness of the solutions. This approach is presented with the hope of being extended to shock regularization of compressible Euler equations

  9. Magnetic evaluation of TSP-filters for air quality monitoring

    Science.gov (United States)

    Castañeda-Miranda, Ana Gabriela; Böhnel, Harald N.; Molina-Garza, Roberto S.; Chaparro, Marcos A. E.

    2014-10-01

    We present the magnetic properties of the powders collected by high volume total suspended particle air samplers used to monitor atmospheric pollution in Santiago de Querétaro, a city of one million people in central Mexico. The magnetic measurements have been combined with scanning electron microscopy observations and analysis, in order to characterize the particles captured in the filters as natural and anthropogenic. The main goal of the study is to test if magnetic measurements on the sampled atmospheric dust can be effective, low-cost, proxy to qualitatively estimate the air quality, complementing the traditional analytical methods. The magnetic properties of the powder collected in the filters have been investigated measuring the low field magnetic susceptibility, hysteresis loops, thermomagnetic curves, and isothermal remanent magnetization. The rock magnetism data have been supplemented by energy-dispersive X-ray spectroscopy analysis and Raman spectroscopy. It was found that the main magnetic carrier is low-Ti magnetite in the PSD range with a contribution from SP particles, and small but significant contributions from hematite, maghemite and goethite particles. Total suspended particles in the atmosphere during the monitored days ranged between about 30 and 280 μg/m3. Magnetic susceptibility values are well correlated with the independently determined total suspended particles concentration (R = 0.93), but particle concentration does not correlate as well with IRM1T. This may be attributed to contributions from SP and paramagnetic particles to the susceptibility signal, but not to the remanence. The effects of climate in particle size, composition and concentration were considered in terms of precipitation and wind intensity, but they are actually minor. The main effect of climate appears to be the removal of SP particles during rainy days. There is a contribution to air pollution from natural mineral sources, which we attribute to low vegetation cover

  10. Molecular filter-based diagnostics in high speed flows

    Science.gov (United States)

    Elliott, Gregory S.; Samimy, MO; Arnette, Stephen A.

    1993-01-01

    The use of iodine molecular filters in nonintrusive planar velocimetry methods is examined. Detailed absorption profiles are obtained to highlight the effects that determine the profile shape. It is shown that pressure broadening induced by the presence of a nonabsorbing vapor can be utilized to significantly change the slopes bounding the absorbing region while remaining in the optically-thick regime.

  11. 3D electroplated inductors with thickness variation for improved broadband performance

    Science.gov (United States)

    Farm-Guoo Tseng, Victor; Bedair, Sarah S.; Lazarus, Nathan

    2017-01-01

    The performance of an RF spiral inductor is based on the balance between ohmic losses in the outer turns and eddy current losses dominant in the inner turns where the magnetic field is the strongest. In this work, air-core spiral inductors with winding trace thicknesses decreasing towards the center are demonstrated, achieving quality factor improvement over a wide frequency range compared to uniform thickness inductors. A custom 3D copper electroplating process was used to produce spiral inductors with varying winding thicknesses in a single plating step, with patterned gaps in a seed layer used to create delays in the vertical plating. The fabricated center-lowered coil inductors were 80 nH within a one square millimeter area with thickness varying from 60 µm to 10 µm from outer to inner winding. Within the 16 MHz-160 MHz range, the center-lowered inductors were shown to have a maximum to minimum quality factor improvement of 90%-10% when compared to uniform thickness inductors with thicknesses ranging from 60 µm to 10 µm. Compared to the 20 µm uniform thickness inductor which has the optimal performance among all uniform thickness inductors in this frequency range, the center-lowered inductors were shown to achieve a maximum quality factor improvement of 20% at the edge frequencies of 16 MHz and 160 MHz, and a minimum quality factor improvement of 10% near the geometric mean center frequency of 46 MHz.

  12. Multichannel Signal Enhancement using Non-Causal, Time-Domain Filters

    DEFF Research Database (Denmark)

    Jensen, Jesper Rindom; Christensen, Mads Græsbøll; Benesty, Jacob

    2013-01-01

    In the vast amount of time-domain filtering methods for speech enhancement, the filters are designed to be causal. Recently, however, it was shown that the noise reduction and signal distortion capabilities of such single-channel filters can be improved by allowing the filters to be non-causal. W......In the vast amount of time-domain filtering methods for speech enhancement, the filters are designed to be causal. Recently, however, it was shown that the noise reduction and signal distortion capabilities of such single-channel filters can be improved by allowing the filters to be non......-causal, multichannel filters for enhancement based on an orthogonal decomposition is proposed. The evaluation shows that there is a potential gain in noise reduction and signal distortion by introducing non-causality. Moreover, experiments on real-life speech show that we can improve the perceptual quality....

  13. Filtering high resolution hyperspectral imagery and analyzing it for quantification of water quality parameters and aquatic vegetation

    Science.gov (United States)

    Pande-Chhetri, Roshan

    High resolution hyperspectral imagery (airborne or ground-based) is gaining momentum as a useful analytical tool in various fields including agriculture and aquatic systems. These images are often contaminated with stripes and noise resulting in lower signal-to-noise ratio, especially in aquatic regions where signal is naturally low. This research investigates effective methods for filtering high spatial resolution hyperspectral imagery and use of the imagery in water quality parameter estimation and aquatic vegetation classification. The striping pattern of the hyperspectral imagery is non-parametric and difficult to filter. In this research, a de-striping algorithm based on wavelet analysis and adaptive Fourier domain normalization was examined. The result of this algorithm was found superior to other available algorithms and yielded highest Peak Signal to Noise Ratio improvement. The algorithm was implemented on individual image bands and on selected bands of the Maximum Noise Fraction (MNF) transformed images. The results showed that image filtering in the MNF domain was efficient and produced best results. The study investigated methods of analyzing hyperspectral imagery to estimate water quality parameters and to map aquatic vegetation in case-2 waters. Ground-based hyperspectral imagery was analyzed to determine chlorophyll-a (Chl-a) concentrations in aquaculture ponds. Two-band and three-band indices were implemented and the effect of using submerged reflectance targets was evaluated. Laboratory measured values were found to be in strong correlation with two-band and three-band spectral indices computed from the hyperspectral image. Coefficients of determination (R2) values were found to be 0.833 and 0.862 without submerged targets and stronger values of 0.975 and 0.982 were obtained using submerged targets. Airborne hyperspectral images were used to detect and classify aquatic vegetation in a black river estuarine system. Image normalization for water

  14. Spin-filter effect in normal metal/ferromagnetic insulator/normal metal/superconductor structures

    International Nuclear Information System (INIS)

    Li, Hong; Yang, Wei; Yang, Xinjian; Qin, Minghui; Guo, Jianqin

    2007-01-01

    Taking into account the thickness of the ferromagnetic insulator, the spin-filter effect in normal metal/ferromagnetic insulator/normal metal/superconductor (NM/FI/NM/SC) junctions is studied based on the Blonder-Tinkham-Klapwijk (BTK) theory. It is shown that a spin-dependent energy shift during the tunneling process induces splitting of the subgap resonance peaks. The spin polarization due to the spin-filter effect of the FI causes an imbalance of the peaks heights and can enhance the Zeeman splitting of the gap peaks caused by an applied magnetic field. The spin-filter effect has no contribution to the proximity-effect-induced superconductivity in NM interlayer

  15. Switching non-local vector median filter

    Science.gov (United States)

    Matsuoka, Jyohei; Koga, Takanori; Suetake, Noriaki; Uchino, Eiji

    2016-04-01

    This paper describes a novel image filtering method that removes random-valued impulse noise superimposed on a natural color image. In impulse noise removal, it is essential to employ a switching-type filtering method, as used in the well-known switching median filter, to preserve the detail of an original image with good quality. In color image filtering, it is generally preferable to deal with the red (R), green (G), and blue (B) components of each pixel of a color image as elements of a vectorized signal, as in the well-known vector median filter, rather than as component-wise signals to prevent a color shift after filtering. By taking these fundamentals into consideration, we propose a switching-type vector median filter with non-local processing that mainly consists of a noise detector and a noise removal filter. Concretely, we propose a noise detector that proactively detects noise-corrupted pixels by focusing attention on the isolation tendencies of pixels of interest not in an input image but in difference images between RGB components. Furthermore, as the noise removal filter, we propose an extended version of the non-local median filter, we proposed previously for grayscale image processing, named the non-local vector median filter, which is designed for color image processing. The proposed method realizes a superior balance between the preservation of detail and impulse noise removal by proactive noise detection and non-local switching vector median filtering, respectively. The effectiveness and validity of the proposed method are verified in a series of experiments using natural color images.

  16. HEPA filter concerns - an overview

    Energy Technology Data Exchange (ETDEWEB)

    Leonard, J.F. [Department of Energy, Washington, DC (United States)

    1995-02-01

    The U.S. Department of Energy (DOE) recently initiated a complete review of the DOE High Efficiency Particulate Air (HEPA) Filter Program to identify areas for improvement. Although this process is currently ongoing, various issues and problems have already been identified for action that not only impacts the DOE HEPA filter program, but potentially the national and international air cleaning community as well. This paper briefly reviews a few of those concerns that may be of interest, and discusses actions initiated by the DOE to address the associated issues and problems. Issues discussed include: guidance standards, in-place testing, specifications, Test Facilities, portable units, vacuum cleaners, substitute aerosols, filter efficiencies, aging/shelf life/service life, fire suppression, handbook, Quality Products List (QPL), QA testing, and evaluations.

  17. Extracting Information about the Electronic Quality of Organic Solar-Cell Absorbers from Fill Factor and Thickness

    Science.gov (United States)

    Kaienburg, Pascal; Rau, Uwe; Kirchartz, Thomas

    2016-08-01

    Understanding the fill factor in organic solar cells remains challenging due to its complex dependence on a multitude of parameters. By means of drift-diffusion simulations, we thoroughly analyze the fill factor of such low-mobility systems and demonstrate its dependence on a collection coefficient defined in this work. We systematically discuss the effect of different recombination mechanisms, space-charge regions, and contact properties. Based on these findings, we are able to interpret the thickness dependence of the fill factor for different experimental studies from the literature. The presented model provides a facile method to extract the photoactive layer's electronic quality which is of particular importance for the fill factor. We illustrate that over the past 15 years, the electronic quality has not been continuously improved, although organic solar-cell efficiencies increased steadily over the same period of time. Only recent reports show the synthesis of polymers for semiconducting films of high electronic quality that are able to produce new efficiency records.

  18. Effect of production variables on microbiological removal in locally-produced ceramic filters for household water treatment.

    Science.gov (United States)

    Lantagne, Daniele; Klarman, Molly; Mayer, Ally; Preston, Kelsey; Napotnik, Julie; Jellison, Kristen

    2010-06-01

    Diarrhoeal diseases cause an estimated 1.87 million child deaths per year. Point-of-use filtration using locally made ceramic filters improves microbiological quality of stored drinking water and prevents diarrhoeal disease. Scaling-up ceramic filtration is inhibited by lack of universal quality control standards. We investigated filter production variables to determine their affect on microbiological removal during 5-6 weeks of simulated normal use. Decreases in the clay:sawdust ratio and changes in the burnable decreased effectiveness of the filter. Method of silver application and shape of filter did not impact filter effectiveness. A maximum flow rate of 1.7 l(-hr) was established as a potential quality control measure for one particular filter to ensure 99% (2- log(10)) removal of total coliforms. Further research is indicated to determine additional production variables associated with filter effectiveness and develop standardized filter production procedures prior to scaling-up.

  19. Discrimination of Cylinders with Different Wall Thicknesses using Neural Networks and Simulated Dolphin Sonar Signals

    DEFF Research Database (Denmark)

    Andersen, Lars Nonboe; Au, Whitlow; Larsen, Jan

    1999-01-01

    This paper describes a method integrating neural networks into a system for recognizing underwater objects. The system is based on a combination of simulated dolphin sonar signals, simulated auditory filters and artificial neural networks. The system is tested on a cylinder wall thickness...... difference experiment and demonstrates high accuracy for small wall thickness differences. Results from the experiment are compared with results obtained by a false killer whale (pseudorca crassidens)....

  20. [Does the mounting of gastrointestinal biopsies on millipore filter contribute to an improved section quality?

    DEFF Research Database (Denmark)

    Asmussen, L.; Bernstein, I.; Matzen, P.

    2009-01-01

    orientation, GIB is occasionally mounted on millipore filter (MF) in an attempt to place the deep cut side onto the MF. The importance of this technique for section quality is evaluated in this study. MATERIAL AND METHOD: The material comprised three consecutive series of GIB (60 gastric, duodenal......, and colorectal GIB, respectively). Sections were grouped in MF-mounted versus non-mounted GIB, the proportion of fully acceptable sections among mounted versus non-mounted GIB was recorded. RESULTS: 77.2% of all GIBs were MF-mounted. 33.1% of mounted GIBs versus 48.8% of non-mounted GIBs were assessed as fully...... acceptable sections. The differences between these figures are not statistically significant. 41.7% of the mounted GIBs were placed with the mucosal surface facing the MF, which entails a risk of damaging the tissue. CONCLUSION: MF-mounting of GIB did not contribute to section quality. Since the handling...

  1. Daily marital interaction quality and carotid artery intima-medial thickness in healthy middle-aged adults.

    Science.gov (United States)

    Joseph, Nataria Tennille; Kamarck, Thomas W; Muldoon, Matthew F; Manuck, Stephen B

    2014-06-01

    To examine the association between marital interaction quality during daily life and subclinical cardiovascular disease (CVD). Studies have shown that marital status and quality of marriage are associated with cardiovascular health. However, little is known about the role of marital interaction quality during daily life in contributing to these effects. The sample consisted of 281 healthy, employed middle-aged adults who were married or living with a partner in a marital-like relationship (mean age = 42.0 years, 88% white, 52% men). Marital interaction quality was assessed using hourly real-time ecological momentary assessments for 4 days, with participants rating their current or recent partner interactions on positive and negative characteristics (e.g., agreeableness and conflict). Carotid artery intima-medial thickness (IMT) was assessed using ultrasound imaging. Adjusting for demographics, positive marital interaction was inversely associated with IMT (b = -0.02, F(1,275) = 9.18, p = .002), and negative marital interaction was positively associated with IMT (b = 0.02 F(1,275) = 10.29, p = .001). These associations were not accounted for by behavioral and biological CVD risk factors and were consistent across age, sex, race, and education. The associations were also independent of marital interaction frequency, nonmarital social interaction quality, and personality factors. Global reports of marital quality, in contrast, were not associated with IMT. Marital quality as measured during real-time interactions between partners was associated with subclinical CVD in healthy middle-aged adults. This study supports the use of real-time social interaction assessment for characterizing links between social relationships and cardiovascular health.

  2. Low pressure chemical vapour deposition of temperature resistant colour filters

    International Nuclear Information System (INIS)

    Verheijen, J.; Bongaerts, P.; Verspui, G.

    1987-01-01

    The possibility to deposit multilayer colour filters, based on optical inference, by means of Low Pressure Chemical Vapour Deposition (LPCVD) was investigated. The filters were made in a standard LPCVD system by alternate deposition of Si/sub 3/N/sub 4/ and SiO/sub 2/ layers. This resulted in filters with excellent colour uniformity on glass and quartz substrates. No difference was measured between theoretically calculated transmission and the transmission of the filters deposited by LPCVD. Temperature treatment at 600 0 C in air air showed no deterioration of filter quality and optical properties

  3. An Analysis of the Quality of the Thick-Walled S355J2+N Steel Joint Welded by the Mag Method

    Directory of Open Access Journals (Sweden)

    Krawczyk R.

    2017-06-01

    Full Text Available An analysis of the quality of the thick-walled S355J2+N steel welded joint used most frequently in the general-building, power and other contemporary steel constructions is presented in the following article. A process of examining welding technologies was made on the tick-walled butt joints of plates by using the MAG – 135 welding method. The aim of the discussed topic was to optimize the process of welding thick-walled welded joints due to their mechanical strength properties and efficiency.

  4. High quality Y-type hexaferrite thick films for microwave applications by an economical and environmentally benign crystal growth technique

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Bolin; Chen, Yajie, E-mail: y.chen@neu.edu; Gillette, Scott; Su, Zhijuan; Harris, Vincent G. [Center for Microwave Magnetic Materials and Integrated Circuits and Department of Electrical and Computer Engineering, Northeastern University, Boston, Massachusetts 02115 (United States); Wolf, Jason; McHenry, Michael E. [Materials Science and Engineering, Carnegie Mellon University, Pittsburgh, Pennsylvania 15213 (United States)

    2014-02-17

    Thick barium hexaferrite Ba{sub 2}Zn{sub 2}Fe{sub 12}O{sub 22} (i.e., Zn{sub 2}Y) films having thicknesses of ∼100 μm were epitaxially grown on MgO (111) substrates using an environmentally benign ferrite-salt mixture by vaporizing the salt. X-ray diffraction pole figure analyses showed (00l) crystallographic alignment with little in plane dispersion confirming epitaxial growth. Saturation magnetization, 4πM{sub s}, was measured for as-grown films to be 2.51 ± 0.1 kG with an out of plane magnetic anisotropy field H{sub A} of 8.9 ± 0.1 kOe. Ferromagnetic resonance linewidth, as the peak-to-peak power absorption derivative at 9.6 GHz, was measured to be 62 Oe. These properties demonstrate a rapid, convenient, cost-effective, and nontoxic method of growing high quality thick crystalline ferrite films which could be used widely for microwave device applications.

  5. An in-flight investigation of pilot-induced oscillation suppression filters during the fighter approach and landing task

    Science.gov (United States)

    Bailey, R. E.; Smith, R. E.

    1982-01-01

    An investigation of pilot-induced oscillation suppression (PIOS) filters was performed using the USAF/Flight Dynamics Laboratory variable stability NT-33 aircraft, modified and operated by Calspan. This program examined the effects of PIOS filtering on the longitudinal flying qualities of fighter aircraft during the visual approach and landing task. Forty evaluations were flown to test the effects of different PIOS filters. Although detailed analyses were not undertaken, the results indicate that PIOS filtering can improve the flying qualities of an otherwise unacceptable aircraft configuration (Level 3 flying qualities). However, the ability of the filters to suppress pilot-induced oscillations appears to be dependent upon the aircraft configuration characteristics. Further, the data show that the filters can adversely affect landing flying qualities if improperly designed. The data provide an excellent foundation from which detail analyses can be performed.

  6. Enhanced Stormwater Contaminant Removal and Improved Runoff Quality Using Modified Sorbents in Tree Filters

    Science.gov (United States)

    Schifman, L. A.; Kasaraneni, V.; Boving, T. B.; Oyanedel-Craver, V.

    2013-12-01

    Stormwater runoff, particularly in urban areas, contains high concentrations of pathogens that are often cited as one of the main reasons for beach closings and other water quality issues in coastal areas. Commonly found contaminants in runoff are often addressed by structural best management practices (BMP) that capture and treat the runoff before discharging it. Many BMP, such as tree filters, act as primary filtration devices that attenuate total suspended solids, nutrients, and heavy metals from runoff, but typically these BMPs are not designed to treat bacteria and have only minor petroleum hydrocarbon (PH) treatment capabilities. To address this shortcoming, the contaminant retention of an alternative sorption material was compared to expanded shale that is usually used in tree filters. Red cedar wood chips were modified with either Quaternary Ammonium Silane (QAS) or Silver Nanoparticles (AgNPs) to provide antimicrobial properties to the matrix and/or exploit their affinity to sorb PH, particularly polycyclic aromatic hydrocarbons (PAH). Results show that the wood chips exhibit the highest sorption capacity for QAS, making this material favorable for treating bacteria, while at the same time attenuating PAH by sorption processes. In the case of AgNP amendment to wood, less AgNP uptake and more desorption from the wood matrix was observed, making this amendment less favorable for bacteria deactivation. Batch experiments show that wood chips modified with QAS can remove up to 3 orders of magnitude of bacteria and retain up to 0.1 mg/g of PAH compared to shale, which has very limited bacteria deactivation (less than one order of magnitude) a PAH retention capacity of 0.04 mg/g. In this talk, the contaminant removal efficiency of the modified and unmodified materials will be discussed on the background of how these materials may find use in enhanced treatment of stormwater in tree filter BMPs.

  7. Design of UWB Filter with WLAN Notch

    Directory of Open Access Journals (Sweden)

    Harish Kumar

    2012-01-01

    Full Text Available UWB technology- (operating in broad frequency range of 3.1–10.6 GHz based filter with WLAN notch has shown great achievement for high-speed wireless communications. To satisfy the UWB system requirements, a band pass filter with a broad pass band width, low insertion loss, and high stop-band suppression are needed. UWB filter with wireless local area network (WLAN notch at 5.6 GHz and 3 dB fractional bandwidth of 109.5% using a microstrip structure is presented. Initially a two-transmission-pole UWB band pass filter in the frequency range 3.1–10.6 GHz is achieved by designing a parallel-coupled microstrip line with defective ground plane structure using GML 1000 substrate with specifications: dielectric constant 3.2 and thickness 0.762 mm at centre frequency 6.85 GHz. In this structure a λ/4 open-circuited stub is introduced to achieve the notch at 5.6 GHz to avoid the interference with WLAN frequency which lies in the desired UWB band. The design structure was simulated on electromagnetic circuit simulation software and fabricated by microwave integrated circuit technique. The measured VNA results show the close agreement with simulated results.

  8. Acoustic wave filter based on periodically poled lithium niobate.

    Science.gov (United States)

    Courjon, Emilie; Bassignot, Florent; Ulliac, Gwenn; Benchabane, Sarah; Ballandras, Sylvain

    2012-09-01

    Solutions for the development of compact RF passive transducers as an alternative to standard surface or bulk acoustic wave devices are receiving increasing interest. This article presents results on the development of an acoustic band-pass filter based on periodically poled ferroelectric domains in lithium niobate. The fabrication of periodically poled transducers (PPTs) operating in the range of 20 to 650 MHz has been achieved on 3-in (76.2-mm) 500-μm-thick wafers. This kind of transducer is able to excite elliptical as well as longitudinal modes, yielding phase velocities of about 3800 and 6500 ms(-1), respectively. A new type of acoustic band-pass filter is proposed, based on the use of PPTs instead of the SAWs excited by classical interdigital transducers. The design and the fabrication of such a filter are presented, as well as experimental measurements of its electrical response and transfer function. The feasibility of such a PPT-based filter is thereby demonstrated and the limitations of this method are discussed.

  9. The effect of aluminium added filter on mean glandular dose using mammography machine in MINT Medical Physics Laboratory

    International Nuclear Information System (INIS)

    Asmaliza Hashim; Wan Hazlinda Ismail; Abd Aziz Mhd Ramli

    2005-01-01

    The effect of various thickness of aluminium added filter on mean glandular dose in mammography is investigated for a standard breast phantom, 4.2 cm Perspex. A mammography machine in Medical Physics Laboratory MINT, Bennett Model DMF-150 is used to provide radiation in various kV range under clinical condition. The mean glandular dose on the phantom were measured based on technique recommended by AAPM protocol (1990) report no 29. The mean glandular dose was found reducing with increasing thickness of added filter. A more detail results of this study is presented in this paper. (Author)

  10. Scanning electron microscope investigations of nuclear pore filters in polyester foils

    International Nuclear Information System (INIS)

    Hopfe, J.

    1980-01-01

    In order to understand and characterize the action of nuclear pore filters it is necessary to know their surface, as well as their bulk, structure. In the present work, investigations of the surface structure (pore size, pore density, pore distribution) and of the pore geometry, especially in the bulk of the filters, are carried out by scanning electron microscopic (SEM) studies. The preparation technique needed is liquid-nitrogen freeze-fracturing followed by a conductive-coating step. Nuclear pore filters studied in this paper were produced by a track etching technique. Laboratory specimens were obtained by bombarding 10 μm thick polyester foils with Xe-ions and a subsequent etching with 20% NaOH. The SEM results are shown and discussed. (author)

  11. Biomedical bandpass filter for fluorescence microscopy imaging based on TiO2/SiO2 and TiO2/MgF2 dielectric multilayers

    International Nuclear Information System (INIS)

    Butt, M A; Fomchenkov, S A; Verma, P; Khonina, S N; Ullah, A

    2016-01-01

    We report a design for creating a multilayer dielectric optical filters based on TiO 2 and SiO 2 /MgF 2 alternating layers. We have selected Titanium dioxide (TiO 2 ) for high refractive index (2.5), Silicon dioxide (SiO 2 ) and Magnesium fluoride (MgF 2 ) as a low refractive index layer (1.45 and 1.37) respectively. Miniaturized visible spectrometers are useful for quick and mobile characterization of biological samples. Such devices can be fabricated by using Fabry-Perot (FP) filters consisting of two highly reflecting mirrors with a central cavity in between. Distributed Bragg Reflectors (DBRs) consisting of alternating high and low refractive index material pairs are the most commonly used mirrors in FP filters, due to their high reflectivity. However, DBRs have high reflectivity for a selected range of wavelengths known as the stopband of the DBR. This range is usually much smaller than the sensitivity range of the spectrometer range. Therefore a bandpass filters are required to restrict wavelength outside the stopband of the FP DBRs. The proposed filter shows a high quality with average transmission of 97.4% within the passbands and the transmission outside the passband is around 4%. Special attention has been given to keep the thickness of the filters within the economic limits. It can be suggested that these filters are exceptional choice for florescence imaging and Endoscope narrow band imaging. (paper)

  12. Fast bilateral filtering of CT-images

    Energy Technology Data Exchange (ETDEWEB)

    Steckmann, Sven; Baer, Matthias; Kachelriess, Marc [Erlangen-Nuernberg Univ., Erlangen (Germany). Inst. of Medical Physics (IMP)

    2011-07-01

    The Bilateral filter is able to get a lower noise level while retaining the edges in images. The downside of a bilateral filter is the high order of the problem itself. While having a Volume size of N with a dimension of d and a filter window of r the problem is of size N{sup d} . r{sup d}. In the literature there are some proposals for speeding up by reducing this order by approximating a component of the filter. This leads to inaccurate results which often implies non acceptable artifacts for medical imaging. A better way for medical imaging is to speed up the filter itself while leaving the basic structure intact. This is the way our implementation uses. We solve the problem of calculating the function of e{sup -x} in an efficient way on modern architectures, and the problem of vectorizing the filtering process. As result we implemented a filter which is 2.5 times faster than the highly optimized basic approach. By comparing the basic analytical approach with the final algorithm, the differences in quality of the computing process is negligible to the human eye. We are able to process a volume with 512{sup 3} voxels with a filter of 25 x 25 x 1 in 21 s on a modern Intel Xeon platform with two X5590 processors running at 3.33 GHz. (orig.)

  13. A fit method for the determination of inherent filtration with diagnostic x-ray units

    International Nuclear Information System (INIS)

    Meghzifene, K; Nowotny, R; Aiginger, H

    2006-01-01

    A method for the determination of total inherent filtration for clinical x-ray units using attenuation curves was devised. A model for the calculation of x-ray spectra is used to calculate kerma values which are then adjusted to the experimental data in minimizing the sum of the squared relative differences in kerma using a modified simplex fit process. The model considers tube voltage, voltage ripple, anode angle and additional filters. Fit parameters are the thickness of an additional inherent Al filter and a general normalization factor. Nineteen sets of measurements including attenuation data for three tube voltages and five Al-filter settings each were obtained. Relative differences of experimental and calculated kerma using the data for the additional filter thickness are within a range of -7.6% to 6.4%. Quality curves, i.e. the relationship of additional filtration to HVL, are often used to determine filtration but the results show that standard quality curves do not reflect the variety of conditions encountered in practice. To relate the thickness of the additional filter to the condition of the anode surface, the data fits were also made using tungsten as the filter material. These fits gave an identical fit quality compared to aluminium with a tungsten filter thickness of 2.12-8.21 μm which is within the range of the additional absorbing layers determined for rough anodes

  14. Prototype heel effect compensation filter for cone-beam CT

    International Nuclear Information System (INIS)

    Mori, Shinichiro; Endo, Masahiro; Nishizawa, Kanae; Ohno, Mari; Miyazaki, Hiroaki; Tsujita, Kazuhiko; Saito, Yasuo

    2005-01-01

    The prototype cone-beam CT (CBCT) has a larger beam width than the conventional multi-detector row CT (MDCT). This causes a non-uniform angular distribution of the x-ray beam intensity known as the heel effect. Scan conditions for CBCT tube current are adjusted on the anode side to obtain an acceptable clinical image quality. However, as the dose is greater on the cathode side than on the anode side, the signal-to-noise ratio on the cathode side is excessively high, resulting in an unnecessary dose amount. To compensate for the heel effect, we developed a heel effect compensation (HEC) filter. The HEC filter rendered the dose distribution uniform and reduced the dose by an average of 25% for free air and by 20% for CTDI phantoms compared to doses with the conventional filter. In addition, its effect in rendering the effective energy uniform resulted in an improvement in image quality. This new HEC filter may be useful in cone-beam CT studies. (note)

  15. Directional Joint Bilateral Filter for Depth Images

    Directory of Open Access Journals (Sweden)

    Anh Vu Le

    2014-06-01

    Full Text Available Depth maps taken by the low cost Kinect sensor are often noisy and incomplete. Thus, post-processing for obtaining reliable depth maps is necessary for advanced image and video applications such as object recognition and multi-view rendering. In this paper, we propose adaptive directional filters that fill the holes and suppress the noise in depth maps. Specifically, novel filters whose window shapes are adaptively adjusted based on the edge direction of the color image are presented. Experimental results show that our method yields higher quality filtered depth maps than other existing methods, especially at the edge boundaries.

  16. Solar-blind ultraviolet band-pass filter based on metal—dielectric multilayer structures

    International Nuclear Information System (INIS)

    Wang Tian-Jiao; Xu Wei-Zong; Lu Hai; Ren Fang-Fang; Chen Dun-Jun; Zhang Rong; Zheng You-Dou

    2014-01-01

    Solar-blind ultraviolet (UV) band-pass filter has significant value in many scientific, commercial, and military applications, in which the detection of weak UV signal against a strong background of solar radiation is required. In this work, a solar-blind filter is designed based on the concept of “transparent metal”. The filter consisting of Al/SiO 2 multilayers could exhibit a high transmission in the solar-blind wavelength region and a wide stopband extending from near-ultraviolet to infrared wavelength range. The central wavelength, bandwidth, Q factor, and rejection ratio of the passband are numerically studied as a function of individual layer thickness and multilayer period. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  17. Construction of x-ray Kβ filters to monochromatize the radiation of a conventional x-ray tube

    International Nuclear Information System (INIS)

    Moreira, M.V.B.; Oliveira, A.G.

    1987-01-01

    The construction of Zr and Nb Kβ filters to produce monochromatic radiation of a conventional X-ray Mo-tube (λK a = 0.7107 A) is described. Disks of NB and Zr, 6.4 mm in diameter and 0.03 to 0.06 mm thick, were prepared. The filters performance was tested by means of NaCl powder difraction patterns. (author) [pt

  18. Arsenic removal from drinking water by a household sand filter in Vietnam--effect of filter usage practices on arsenic removal efficiency and microbiological water quality.

    Science.gov (United States)

    Nitzsche, Katja Sonja; Lan, Vi Mai; Trang, Pham Thi Kim; Viet, Pham Hung; Berg, Michael; Voegelin, Andreas; Planer-Friedrich, Britta; Zahoransky, Jan; Müller, Stefanie-Katharina; Byrne, James Martin; Schröder, Christian; Behrens, Sebastian; Kappler, Andreas

    2015-01-01

    Household sand filters are applied to treat arsenic- and iron-containing anoxic groundwater that is used as drinking water in rural areas of North Vietnam. These filters immobilize poisonous arsenic (As) via co-oxidation with Fe(II) and sorption to or co-precipitation with the formed Fe(III) (oxyhydr)oxides. However, information is lacking regarding the effect of the frequency and duration of filter use as well as of filter sand replacement on the residual As concentrations in the filtered water and on the presence of potentially pathogenic bacteria in the filtered and stored water. We therefore scrutinized a household sand filter with respect to As removal efficiency and the presence of fecal indicator bacteria in treated water as a function of filter operation before and after sand replacement. Quantification of As in the filtered water showed that periods of intense daily use followed by periods of non-use and even sand replacement did not significantly (psand replacement, CFUs of Escherichia coli of sand filters regarding As removal, but indicate a potential risk for human health arising from the enrichment of coliform bacteria during filtration and from E. coli cells that are introduced by sand replacement. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Design and engineering of IZO/Ag/glass solar filters for low-emissivity window performance

    Science.gov (United States)

    Hernandez-Mainet, Luis C.; Aguilar, Miguel A.; Tamargo, Maria C.; Falcony, Ciro

    2017-10-01

    The electricity consumption in houses and commercial buildings generates about 18% of greenhouse gas emission. A critical issue of building energy consumption is heat and cooling loss through the window. Low-emissivity windows control thermal radiation through glass without decreasing the intensity of visible light. They are made up of optical filter coatings grown on a flat glass surface. Solar filters based on Ag/IZO multilayer films are grown and simulated on glass substrate. The targeted structure designs are grown by a sputtering system and characterized by scanning electron microscopy and x-ray diffraction techniques. To accurately simulate transmission spectrum, silver (Ag) and IZO optical constants were estimated by fitting ellipsometric data at different thicknesses. Transmission spectrum shows a good agreement among experiment and simulation. In addition, optical constant curves strongly show layer thickness dependence in both materials. In particular, the ultrathin Ag layer displays a percolation threshold in the vicinity of 15 nm, which leads to surface plasmon resonance with absorption at about 450 nm. These types of optical filter coatings would have potential applications as low-emission windows.

  20. Feasibility Studies of the Two Filters Method in TJ-II for Electron Temperature Measurements in High Density Plasmas

    International Nuclear Information System (INIS)

    Baiao, D.; Medina, F.; Ochando, M.; Varandas, C.

    2009-01-01

    The TJ-II plasma soft X-ray emission was studied in order to establish an adequate setup for an electron temperature diagnostic suitable for high density, with spatial and temporal resolutions, based on the two-filters method. The preliminary experimental results reported were obtained with two diagnostics (an X-ray PHA based on a Ge detector and a tomography system) already installed in TJ-II stellarator. These results lead to the conclusion that the two-filters method was a suitable option for an electron temperature diagnostic for high-density plasmas in TJ-II. We present the design and fi rst results obtained with a prototype for the measurement of electron temperature in TJ-II plasmas heated with energetic neutral beams. This system consists in two AXUV20A detectors which measure the soft X-ray plasma emissivity trough beryllium filters of different thickness. From the two-filters technique it is possible to estimate the electron temperature. The analyses carried out allowed concluding which filter thicknesses are most suited for TJ-II plasmas, and enhanced the need of a computer code to simulate signals and plasma compositions. (Author) 7 refs.

  1. Feasibility Studies of the Two Filters Method in TJ-II for Electron Temperature Measurements in High Density Plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Baiao, D.; Medina, F.; Ochando, M.; Varandas, C.

    2009-07-01

    The TJ-II plasma soft X-ray emission was studied in order to establish an adequate setup for an electron temperature diagnostic suitable for high density, with spatial and temporal resolutions, based on the two-filters method. The preliminary experimental results reported were obtained with two diagnostics (an X-ray PHA based on a Ge detector and a tomography system) already installed in TJ-II stellarator. These results lead to the conclusion that the two-filters method was a suitable option for an electron temperature diagnostic for high-density plasmas in TJ-II. We present the design and fi rst results obtained with a prototype for the measurement of electron temperature in TJ-II plasmas heated with energetic neutral beams. This system consists in two AXUV20A detectors which measure the soft X-ray plasma emissivity trough beryllium filters of different thickness. From the two-filters technique it is possible to estimate the electron temperature. The analyses carried out allowed concluding which filter thicknesses are most suited for TJ-II plasmas, and enhanced the need of a computer code to simulate signals and plasma compositions. (Author) 7 refs.

  2. The 2D Hotelling filter - a quantitative noise-reducing principal-component filter for dynamic PET data, with applications in patient dose reduction

    International Nuclear Information System (INIS)

    Axelsson, Jan; Sörensen, Jens

    2013-01-01

    In this paper we apply the principal-component analysis filter (Hotelling filter) to reduce noise from dynamic positron-emission tomography (PET) patient data, for a number of different radio-tracer molecules. We furthermore show how preprocessing images with this filter improves parametric images created from such dynamic sequence. We use zero-mean unit variance normalization, prior to performing a Hotelling filter on the slices of a dynamic time-series. The Scree-plot technique was used to determine which principal components to be rejected in the filter process. This filter was applied to [ 11 C]-acetate on heart and head-neck tumors, [ 18 F]-FDG on liver tumors and brain, and [ 11 C]-Raclopride on brain. Simulations of blood and tissue regions with noise properties matched to real PET data, was used to analyze how quantitation and resolution is affected by the Hotelling filter. Summing varying parts of a 90-frame [ 18 F]-FDG brain scan, we created 9-frame dynamic scans with image statistics comparable to 20 MBq, 60 MBq and 200 MBq injected activity. Hotelling filter performed on slices (2D) and on volumes (3D) were compared. The 2D Hotelling filter reduces noise in the tissue uptake drastically, so that it becomes simple to manually pick out regions-of-interest from noisy data. 2D Hotelling filter introduces less bias than 3D Hotelling filter in focal Raclopride uptake. Simulations show that the Hotelling filter is sensitive to typical blood peak in PET prior to tissue uptake have commenced, introducing a negative bias in early tissue uptake. Quantitation on real dynamic data is reliable. Two examples clearly show that pre-filtering the dynamic sequence with the Hotelling filter prior to Patlak-slope calculations gives clearly improved parametric image quality. We also show that a dramatic dose reduction can be achieved for Patlak slope images without changing image quality or quantitation. The 2D Hotelling-filtering of dynamic PET data is a computer

  3. Daily Marital Interaction Quality and Carotid Artery Intima Medial Thickness in Healthy Middle Aged Adults

    Science.gov (United States)

    Joseph, Nataria T.; Kamarck, Thomas W.; Muldoon, Matthew F.; Manuck, Stephen B.

    2014-01-01

    Objective To examine the association between marital interaction quality during daily life and subclinical cardiovascular disease (CVD). Studies have shown that marital status and quality of marriage are associated with cardiovascular health. However, little is known about the role of marital interaction quality during daily life in contributing to these effects. Methods The sample consisted of 281 healthy, employed middle-aged adults who were married or living with a partner in a marital-like relationship (mean age = 42.0 years, 88% white, 52% men). Marital interaction quality was assessed using hourly real-time Ecological Momentary Assessments (EMAs) for 4 days, with participants rating their current or recent partner interactions on positive and negative characteristics (e.g., agreeableness and conflict). Carotid artery intima medial thickness (IMT) was assessed using ultrasound imaging. Results Adjusting for demographics, positive marital interaction was inversely associated with IMT, [b = −.02 F(1, 275) = 9.18, p = .002], and negative marital interaction was positively associated with IMT, [b = .02 F(1, 275) = 10.29, p = .001]. These associations were not accounted for by behavioral and biological cardiovascular disease (CVD) risk factors and were consistent across age, sex, race, and education. The associations were also independent of marital interaction frequency, nonmarital social interaction quality, and personality factors. Global reports of marital quality, in contrast, were not associated with IMT. Conclusions Marital quality as measured during real-time interactions between partners was associated with subclinical cardiovascular disease in healthy middle-aged adults. This study supports the utility of real-time social interaction assessment for characterizing links between social relationships and cardiovascular health. PMID:24915293

  4. Absolute air filtering equipment in the nuclear industrie. Design - Safety - Experience

    International Nuclear Information System (INIS)

    Lucas, J.C.

    1977-01-01

    The problems encountered in the design of absolute filters (HEPA FILTERS) are presented: glass-fibre filter papers; standards and characteristics: efficiency, fire-resistance, humidity-resistance, radiation-resistance, etc; various types of paper folding: deep folds and small folds, dihedrally mounted; filtering elements; designs; characteristics and quality control; The design of filtration equipment is also analysed: mounting in metal or concrete casings. French and American designs (Regulatory Guide 1-52); and gas-tight casings allowing contaminated filters to be renewed without breaking the gas-tight seal

  5. Dynamic beam filtering for miscentered patients.

    Science.gov (United States)

    Mao, Andrew; Shyr, William; Gang, Grace J; Stayman, J Webster

    2018-02-01

    Accurate centering of the patient within the bore of a CT scanner takes time and is often difficult to achieve precisely. Patient miscentering can result in significant dose and image noise penalties with the use of traditional bowtie filters. This work describes a system to dynamically position an x-ray beam filter during image acquisition to enable more consistent image performance and potentially lower dose needed for CT imaging. We propose a new approach in which two orthogonal low-dose scout images are used to estimate a parametric model of the object describing its shape, size, and location within the field of view (FOV). This model is then used to compute an optimal filter motion profile by minimizing the variance of the expected detector fluence for each projection. Dynamic filtration was implemented on a cone-beam CT (CBCT) test bench using two different physical filters: 1) an aluminum bowtie and 2) a structured binary filter called a multiple aperture device (MAD). Dynamic filtration performance was compared to a static filter in studies of dose and reconstruction noise as a function of the degree of miscentering of a homogeneous water phantom. Estimated filter trajectories were found to be largely sinusoidal with an amplitude proportional to the amount of miscentering. Dynamic filtration demonstrated an improved ability to keep the spatial distribution of dose and reconstruction noise at baseline levels across varying levels of miscentering, reducing the maximum noise and dose deviation from 53% to 15% and 42% to 14% respectively for the bowtie filter, and 25% to 8% and 24% to 15% respectively for the MAD filter. Dynamic positioning of beam filters during acquisition improves dose utilization and image quality over static filters for miscentered patients. Such dynamic filters relax positioning requirements and have the potential to reduce set-up time and lower dose requirements.

  6. A post-implementation evaluation of ceramic water filters distributed to tsunami-affected communities in Sri Lanka.

    Science.gov (United States)

    Casanova, Lisa M; Walters, Adam; Naghawatte, Ajith; Sobsey, Mark D

    2012-06-01

    Sri Lanka was devastated by the 2004 Indian Ocean tsunami. During recovery, the Red Cross distributed approximately 12,000 free ceramic water filters. This cross-sectional study was an independent post-implementation assessment of 452 households that received filters, to determine the proportion still using filters, household characteristics associated with use, and quality of household drinking water. The proportion of continued users was high (76%). The most common household water sources were taps or shallow wells. The majority (82%) of users used filtered water for drinking only. Mean filter flow rate was 1.12 L/hr (0.80 L/hr for households with taps and 0.71 for those with wells). Water quality varied by source; households using tap water had source water of high microbial quality. Filters improved water quality, reducing Escherichia coli for households (largely well users) with high levels in their source water. Households were satisfied with filters and are potentially long-term users. To promote sustained use, recovery filter distribution efforts should try to identify households at greatest long-term risk, particularly those who have not moved to safer water sources during recovery. They should be joined with long-term commitment to building supply chains and local production capacity to ensure safe water access.

  7. Filter assessment applied to analytical reconstruction for industrial third-generation tomography

    Energy Technology Data Exchange (ETDEWEB)

    Velo, Alexandre F.; Martins, Joao F.T.; Oliveira, Adriano S.; Carvalho, Diego V.S.; Faria, Fernando S.; Hamada, Margarida M.; Mesquita, Carlos H., E-mail: afvelo@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Multiphase systems are structures that contain a mixture of solids, liquids and gases inside a chemical reactor or pipes in a dynamic process. These systems are found in chemical, food, pharmaceutical and petrochemical industries. The gamma ray computed tomography (CT) system has been applied to visualize the distribution of multiphase systems without interrupting production. CT systems have been used to improve design, operation and troubleshooting of industrial processes. Computer tomography for multiphase processes is being developed at several laboratories. It is well known that scanning systems demand high processing time, limited set of data projections and views to obtain an image. Because of it, the image quality is dependent on the number of projection, number of detectors, acquisition time and reconstruction time. A phantom containing air, iron and aluminum was used on the third generation industrial tomography with 662 keV ({sup 137}Cs) radioactive source. It was applied the Filtered Back Projection algorithm to reconstruct the images. An efficient tomography is dependent of the image quality, thus the objective of this research was to apply different types of filters on the analytical algorithm and compare each other using the figure of merit denominated root mean squared error (RMSE), the filter that presents lower value of RMSE has better quality. On this research, five types of filters were used: Ram-Lak, Shepp-Logan, Cosine, Hamming and Hann filters. As results, all filters presented lower values of RMSE, that means the filters used have low stand deviation compared to the mass absorption coefficient, however, the Hann filter presented better RMSE and CNR compared to the others. (author)

  8. Filter assessment applied to analytical reconstruction for industrial third-generation tomography

    International Nuclear Information System (INIS)

    Velo, Alexandre F.; Martins, Joao F.T.; Oliveira, Adriano S.; Carvalho, Diego V.S.; Faria, Fernando S.; Hamada, Margarida M.; Mesquita, Carlos H.

    2015-01-01

    Multiphase systems are structures that contain a mixture of solids, liquids and gases inside a chemical reactor or pipes in a dynamic process. These systems are found in chemical, food, pharmaceutical and petrochemical industries. The gamma ray computed tomography (CT) system has been applied to visualize the distribution of multiphase systems without interrupting production. CT systems have been used to improve design, operation and troubleshooting of industrial processes. Computer tomography for multiphase processes is being developed at several laboratories. It is well known that scanning systems demand high processing time, limited set of data projections and views to obtain an image. Because of it, the image quality is dependent on the number of projection, number of detectors, acquisition time and reconstruction time. A phantom containing air, iron and aluminum was used on the third generation industrial tomography with 662 keV ( 137 Cs) radioactive source. It was applied the Filtered Back Projection algorithm to reconstruct the images. An efficient tomography is dependent of the image quality, thus the objective of this research was to apply different types of filters on the analytical algorithm and compare each other using the figure of merit denominated root mean squared error (RMSE), the filter that presents lower value of RMSE has better quality. On this research, five types of filters were used: Ram-Lak, Shepp-Logan, Cosine, Hamming and Hann filters. As results, all filters presented lower values of RMSE, that means the filters used have low stand deviation compared to the mass absorption coefficient, however, the Hann filter presented better RMSE and CNR compared to the others. (author)

  9. Early cystic bleb needling revision after glaucoma filtering surgery with toxic keratopathy

    Directory of Open Access Journals (Sweden)

    S. Yu. Petrov

    2015-01-01

    Full Text Available Clinical case of high thin-wall cystic limited filtering bleb needling revision in the early post-op period after trabeculectomy with sinusotomy accompanied by toxic keratopathy is presented. Optical coherence tomography (OCT demonstrated that filtering bleb height was 2700 μm and bleb wall thickness was 70 μm. Bleb needling revision with its lateralwall dissection and subconjunctival injection of dexamethasone, fluorouracil, and ranibizumab near to the bleb site was performed. In 1.5 hours after the procedure, bleb height decreased to 550 μm (by 5 times while bleb wall thickness increased up to 100 μm. Topical antibacterial, steroid, and non-steroid anti-inflammatory therapy was recommended. The next day IOP level reduced from 11 mm Hg to 4.5 mm Hg. It was accompanied by choroidal effusion that was managed conservatively with cycloplegic agents (drops and injections for 3 days. On day 6, central corneal edema affecting all layers, Descemet’s membrane folds, and ocular hypertension were revealed. Metabolic therapy resolved corneal edema within 3 days. Re-needling bleb revision decreased IOP level to 6.2 mm Hg. This resulted in transient Descemet’s membrane folds. This paper describes filtering bleb needling revision with its lateral wall dissection and anti-inflammatory, cytostatic, and anti-VEGF agents use to prolong glaucoma filtering surgery effect in excessive scarring. The procedure was accompanied by toxic corneal endothelium decompensation with corneal edema and Descemet’s membrane folds treated with active metabolic therapy.

  10. Influence of slice thickness on the determination of left ventricular wall thickness and dimension by magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Ohnishi, Shusaku; Fukui, Sugao; Atsumi, Chisato and others

    1989-02-01

    Wall thickness of the ventricular septum and left ventricle, and left ventricular cavity dimension were determined on magnetic resonance (MR) images with slices 5 mm and 10 mm in thickness. Subjects were 3 healthy volunteers and 7 patients with hypertension (4), hypertrophic cardiomyopathy (one) or valvular heart disease (2). In visualizing the cardiac structures such as left ventricular papillary muscle and right and left ventricles, 5 mm-thick images were better than 10 mm-thick images. Edges of ventricular septum and left ventricular wall were more clearly visualized on 5 mm-thick images than 10 mm-thick images. Two mm-thick MR images obtained from 2 patients yielded the most excellent visualization in end-systole, but failed to reveal cardiac structures in detail in end-diastole. Phantom studies revealed no significant differences in image quality of 10 mm and 5 mm in thickness in the axial view 80 degree to the long axis. In the axial view 45 degree to the long axis, 10 mm-thick images were inferior to 5 mm-thick images in detecting the edge of the septum and the left ventricular wall. These results indicate that the selection of slice thickness is one of the most important determinant factors in the measurement of left ventricular wall thickness and cavity dimension. (Namekawa, K).

  11. Influence of slice thickness on the determination of left ventricular wall thickness and dimension by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Ohnishi, Shusaku; Fukui, Sugao; Atsumi, Chisato

    1989-01-01

    Wall thickness of the ventricular septum and left ventricle, and left ventricular cavity dimension were determined on magnetic resonance (MR) images with slices 5 mm and 10 mm in thickness. Subjects were 3 healthy volunteers and 7 patients with hypertension (4), hypertrophic cardiomyopathy (one) or valvular heart disease (2). In visualizing the cardiac structures such as left ventricular papillary muscle and right and left ventricles, 5 mm-thick images were better than 10 mm-thick images. Edges of ventricular septum and left ventricular wall were more clearly visualized on 5 mm-thick images than 10 mm-thick images. Two mm-thick MR images obtained from 2 patients yielded the most excellent visualization in end-systole, but failed to reveal cardiac structures in detail in end-diastole. Phantom studies revealed no significant differences in image quality of 10 mm and 5 mm in thickness in the axial view 80 degree to the long axis. In the axial view 45 degree to the long axis, 10 mm-thick images were inferior to 5 mm-thick images in detecting the edge of the septum and the left ventricular wall. These results indicate that the selection of slice thickness is one of the most important determinant factors in the measurement of left ventricular wall thickness and cavity dimension. (Namekawa, K)

  12. Sediment quality guidelines for copper and zinc for filter-feeding estuarine oysters?

    Energy Technology Data Exchange (ETDEWEB)

    Birch, G.F., E-mail: gavin.birch@sydney.edu.a [Environmental Geology Group, School of Geosciences, Sydney University, NSW (Australia); Hogg, T.D. [Environmental Geology Group, School of Geosciences, Sydney University, NSW (Australia)

    2011-01-15

    Sediment quality guidelines (SQGs) assess the ability of bottom sediment to sustain healthy infauna and water quality guidelines (WQGs) provide protection for a designated percentage of aquatic species. Filter-feeding marine species, e.g. oysters and mussels, acquire food from particles in the water column and protection of these animals is not provided by SQGs or WQGs. The current work investigated the relationship between metal (Cu, Zn) concentrations in total and fine-fraction (<62.5 {mu}m) surficial sediment digested in a range of acids and chelating agents and oyster tissue metal concentrations. A strong correlation between oyster tissue Cu and Zn concentrations and fine-fraction surficial sediment digested in 1 M HCl provided a sedimentary guideline which predicted tissue metal concentrations in oysters and established a level (<45 {mu}g g{sup -1} and <1000 {mu}g g{sup -1}, respectively) for protecting oysters from exceeding human consumption levels (70 {mu}g g{sup -1} and 1000 {mu}g g{sup -1}, respectively). - A strong correlation between oyster tissue Cu and Zn concentrations and fine-fraction surficial sediment digested in 1 M HCl provided a sedimentary guideline which predicted tissue metal concentrations in oysters and established a level for protecting oysters from exceeding human consumption levels for these metals. The guidelines for fine surficial sediment developed in the present work accurately predicted oyster tissue concentrations in the field.

  13. Reduction of bacteria and somatic coliphages in constructed wetlands for the treatment of combined sewer overflow (retention soil filters).

    Science.gov (United States)

    Ruppelt, Jan P; Tondera, Katharina; Schreiber, Christiane; Kistemann, Thomas; Pinnekamp, Johannes

    2018-05-01

    Combined sewer overflows (CSOs) introduce numerous pathogens from fecal contamination, such as bacteria and viruses, into surface waters, thus endangering human health. In Germany, retention soil filters (RSFs) treat CSOs at sensitive discharge points and can contribute to reducing these hygienically relevant microorganisms. In this study, we evaluated the extent of how dry period, series connection and filter layer thickness influence the reduction efficiency of RSFs for Escherichia coli (E. coli), intestinal enterococci (I. E.) and somatic coliphages. To accomplish this, we had four pilot scale RSFs built on a test field at the wastewater treatment plant Aachen-Soers. While two filters were replicates, the other two filters were installed in a series connection. Moreover, one filter had a thinner filtration layer than the other three. Between April 2015 and December 2016, the RSFs were loaded in 37 trials with pre-conditioned CSO after dry periods ranging from 4 to 40 days. During 17 trials, samples for microbial analysis were taken and analyzed. The series connection of two filters showed that the removal increases when two systems with a filter layer of the same height are operated in series. Since the microorganisms are exposed twice to the environmental conditions on the filter surface and in the upper filter layers, there is a greater chance for abiotic adsorption increase. The same effect could be shown when filters with different depths were compared: the removal efficiency increases as filter thickness increases. This study provides new evidence that regardless of seasonal effects and dry period, RSFs can improve hygienic situation significantly. Copyright © 2018 Elsevier GmbH. All rights reserved.

  14. A robust nonlinear filter for image restoration.

    Science.gov (United States)

    Koivunen, V

    1995-01-01

    A class of nonlinear regression filters based on robust estimation theory is introduced. The goal of the filtering is to recover a high-quality image from degraded observations. Models for desired image structures and contaminating processes are employed, but deviations from strict assumptions are allowed since the assumptions on signal and noise are typically only approximately true. The robustness of filters is usually addressed only in a distributional sense, i.e., the actual error distribution deviates from the nominal one. In this paper, the robustness is considered in a broad sense since the outliers may also be due to inappropriate signal model, or there may be more than one statistical population present in the processing window, causing biased estimates. Two filtering algorithms minimizing a least trimmed squares criterion are provided. The design of the filters is simple since no scale parameters or context-dependent threshold values are required. Experimental results using both real and simulated data are presented. The filters effectively attenuate both impulsive and nonimpulsive noise while recovering the signal structure and preserving interesting details.

  15. Eggshell thickness variation in red-legged partridge (Alectoris rufa) from Spain

    DEFF Research Database (Denmark)

    Castilla, Aurora M.; de Aragón, Juan Martínez; Herrel, Anthony

    2009-01-01

    Eggshell thickness is commonly used as an indicator of habitat quality and effects of environmental pollution on avian reproduction. We present the first data available on eggshell thickness for Red-legged Partridge (Alectoris rufa) in Spain. We compared eggshell thickness between eggs collected...

  16. A Controlled Design of Ripple-Like Polyamide-6 Nanofiber/Nets Membrane for High-Efficiency Air Filter.

    Science.gov (United States)

    Zhang, Shichao; Liu, Hui; Zuo, Fenglei; Yin, Xia; Yu, Jianyong; Ding, Bin

    2017-03-01

    The filtration capacity of fibrous media for airborne particles is restricted by their thick diameter, low porosity, and limited frontal area. The ability to solve this problem would have broad technological implications for various air filtration applications; despite many past efforts, it remains a great challenge to achieve. Herein, a facile and scalable strategy to fabricate the ripple-like polyamide-6 nanofiber/nets (PA-6 NF/N) air filter via combining electrospinning/netting technique with receiving substrate design is demonstrated. This proposed approach allows the scaffold filaments to orderly embed into 2D PA-6 nanonets layer with Steiner-tree structures and nanoscale diameter of ≈20 nm, resulting in the ripple-like membrane with extremely small pore size, highly porous structure, and hugely extended frontal surface, by facilely adjusting its pleat span and pleat pitch. These unique structural advantages enable the ripple-like PA-6 NF/N filter to filtrate the ultrafine particles with high removal efficiency of 99.996%, low air resistance of 95 Pa, and robust quality factor of >0.11 Pa -1 ; using its superlight weight of 0.9 g m -2 and physical sieving manner. This approach has the potentialities to give rise to a novel generation of filter media displaying enhanced filtration capacity for various applications thanks to their nanoscale features and designed macrostructures. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Loss of collected particles from the filter of the stack monitor, the Ringhals-1 power reactor

    International Nuclear Information System (INIS)

    Stroem, L.

    1993-01-01

    The function of the filter holder was examined in the laboratory and in the Ringhals measurement installation. It was concluded that a loss of sample could occur, if the filter has a heavy particle deposit. An approximate relation between deposits thickness and loss of sample could be determined. Particle concentration in the stack air is sometimes so high, that loss of sample can occur. The test have also revealed that the sample air stream can by-pass the filter, without proper indication of the defect. Control instrumentation is proposed

  18. Computation of beam quality parameters for Mo/Mo, Mo/Rh, Rh/Rh, and W/Al target/filter combinations in mammography

    International Nuclear Information System (INIS)

    Kharrati, Hedi; Zarrad, Boubaker

    2003-01-01

    A computer program was implemented to predict mammography x-ray beam parameters in the range 20-40 kV for Mo/Mo, Mo/Rh, Rh/Rh, and W/Al target/filter combinations. The computation method used to simulate mammography x-ray spectra is based on the Boone et al. model. The beam quality parameters such as the half-value layer (HVL), the homogeneity coefficient (HC), and the average photon energy were computed by simulating the interaction of the spectrum photons with matter. The checking of this computation was done using a comparison of the results with published data and measured values obtained at the Netherlands Metrology Institute Van Swinden Laboratorium, National Institute of Standards and Technology, and International Atomic Energy Agency. The predicted values with a mean deviation of 3.3% of HVL, 3.7% of HC, and 1.5% of average photon energy show acceptable agreement with published data and measurements for all target/filter combinations in the 23-40 kV range. The accuracy of this computation can be considered clinically acceptable and can allow an appreciable estimation for the beam quality parameters

  19. Critical thickness of high structural quality SrTiO3 films grown on orthorhombic (101) DyScO3

    International Nuclear Information System (INIS)

    Biegalski, M. D.; Trolier-McKinstry, S.; Schlom, D. G.; Fong, D. D.; Eastman, J. A.; Fuoss, P. H.; Streiffer, S. K.; Heeg, T.; Schubert, J.; Tian, W.; Nelson, C. T.; Pan, X. Q.; Hawley, M. E.; Bernhagen, M.; Reiche, P.; Uecker, R.

    2008-01-01

    Strained epitaxial SrTiO 3 films were grown on orthorhombic (101) DyScO 3 substrates by reactive molecular-beam epitaxy. The epitaxy of this substrate/film combination is cube on cube with a pseudocubic out-of-plane (001) orientation. The strain state and structural perfection of films with thicknesses ranging from 50 to 1000 A were examined using x-ray scattering. The critical thickness at which misfit dislocations was introduced was between 350 and 500 A. These films have the narrowest rocking curves (full width at half maximum) ever reported for any heteroepitaxial oxide film (0.0018 deg.). Only a modest amount of relaxation is seen in films exceeding the critical thicknesses even after postdeposition annealing at 700 deg. C in 1 atm of oxygen. The dependence of strain relaxation on crystallographic direction is attributed to the anisotropy of the substrate. These SrTiO 3 films show structural quality more typical of semiconductors such as GaAs and silicon than perovskite materials; their structural relaxation behavior also shows similarity to that of compound semiconductor films

  20. Geology, hydrology, thickness and quality of salt at three alternate sites for disposal of radioactive waste in Kansas

    International Nuclear Information System (INIS)

    Bayne, C.K.; Brinkley, C.

    1972-09-01

    The three sites selected by the AEC for additional study for the disposal of radioactive wastes in Kansas are; Site A located in south-central Lincoln County, Site D-2 located in south-central Wichita County, and Site A-1 located in north-western Lincoln County. Results of the study show that all sites failed to meet the detailed criteria. Areas A and A-1 fail to meet the criteria concerning thickness and quality. Area D-2 fails to meet the criteria concerning quality and mineability of the salt. Areas west of Site A-1 and in south-central Harper County, in the authors' opinion, appear to be the best prospects for future study in Kansas

  1. The Power Quality Compensation Strategy for Power Distribution System Based on Hybrid Parallel Active Power Filters

    Directory of Open Access Journals (Sweden)

    Rachid DEHINI

    2010-12-01

    Full Text Available In this paper, the main aim is to confront the performance of shunt active power filter (SAPF and the shunt hybrid active power filter (SHAPF to achieve flexibility and reliability of the filter devices. Both of the two devices used the classical proportional-integral controller for pulse generation to trigger the inventers MOSFET’s. In the adopted hybrid active filter there is a passive power filter with high power rating to filter the low order harmonies and one active filter with low power rating to filter the other high order harmonies. In order to investigate the effectiveness of (SHAPF, the studies have been accomplished using simulation with the MATLAB-SIMULINK. The results show That (SHAPF is more effective than (SAPF, and has lower cost.

  2. Single Crystal Filters for Neutron Spectrometry

    International Nuclear Information System (INIS)

    Habib, N.

    2008-01-01

    A study of neutron transmission properties trough a large single crystals specimens of Si, Ge, Pb, Bi and sapphire at 300 K and 80 K have been made for a wide range of neutron energies. The effectiveness of such filters is given by the ratio of the total cross-section of unwanted epithermal neutrons to that the desired thermal neutron beam and by the optimum choice of the crystal orientation, its mosaic spread, thickness and temperature.Our study indicates that sapphire is significantly more effective than the others for a wide range of neutron energies

  3. Water Quality of Trickling Biological Periwinkle Shells Filter for ...

    African Journals Online (AJOL)

    Studies were carried on the design, efficiency and economics of trickling biological periwinkle shells filter in recirculating aquaculture systems for catfish production. The designed biofilter and other system components were constructed, assembled and commissioned for pilot catfish production. The system with the designed ...

  4. Health-related quality of life and patient burden in patients with split-thickness skin graft donor site wounds.

    Science.gov (United States)

    Humrich, Marco; Goepel, Lisa; Gutknecht, Mandy; Lohrberg, David; Blessmann, Marco; Bruning, Guido; Diener, Holger; Dissemond, Joachim; Hartmann, Bernd; Augustin, Matthias

    2018-04-01

    Split-thickness skin grafting is a common procedure to treat different kinds of wounds. This systematic, multicentre, observational, cross-sectional study of adult patients with split-thickness skin graft (STSG) donor site wounds was conducted to evaluate quality of life (QoL) impairments caused by donor site wounds following split-thickness skin grafting. Therefore, 112 patients from 12 wound centres in Germany were examined based on patient and physician questionnaires as well as a physical examination of the donor site wound. Most indications for skin grafting were postsurgical treatment (n = 51; 42.5%) and chronic wounds (n = 47; 39.2%). European QoL visual analoque scale (EQ VAS) averaged 64.7 ± 23.3, European QoL 5 dimensions (EQ-5D) averaged 77.4 ± 30.0. Wound-QoL (range: 0-4) was rated 0.8 ± 0.8 post-surgery and 0.4 ± 0.6 at the time of survey (on average 21 weeks between the time points). Compared to averaged Wound-QoL scores of chronic wounds donor site-related QoL impairments in split-thickness skin-graft patients were less pronounced. There were significant differences in patient burden immediately after surgery compared to the time of the survey, with medium effect sizes. This supports the hypothesis that faster healing of the donor site wound leads to more favourable patient-reported outcomes. © 2017 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  5. Fractional kalman filter to estimate the concentration of air pollution

    Science.gov (United States)

    Vita Oktaviana, Yessy; Apriliani, Erna; Khusnul Arif, Didik

    2018-04-01

    Air pollution problem gives important effect in quality environment and quality of human’s life. Air pollution can be caused by nature sources or human activities. Pollutant for example Ozone, a harmful gas formed by NOx and volatile organic compounds (VOCs) emitted from various sources. The air pollution problem can be modeled by TAPM-CTM (The Air Pollution Model with Chemical Transport Model). The model shows concentration of pollutant in the air. Therefore, it is important to estimate concentration of air pollutant. Estimation method can be used for forecast pollutant concentration in future and keep stability of air quality. In this research, an algorithm is developed, based on Fractional Kalman Filter to solve the model of air pollution’s problem. The model will be discretized first and then it will be estimated by the method. The result shows that estimation of Fractional Kalman Filter has better accuracy than estimation of Kalman Filter. The accuracy was tested by applying RMSE (Root Mean Square Error).

  6. A paired wedge filter system for compensation in dose differences

    International Nuclear Information System (INIS)

    Kobayashi, H.; Sakurai, Y.; Kondo, S.; Abe, S.; Hayakawa, N.; Aoyama, Y.; Obata, Y.; Ishigaki, T.

    1998-01-01

    Objective: In radiotherapy, it is important to conform the high dose volume to the planned target volume. A variable thickness paired wedge filter system was developed to compensate for dose inhomogeneity arising from field width segment variation in conformal irradiation. Materials and methods: The present study used a 6 MV linear accelerator equipped with multileaf collimator leaves and a paired wedge compensating filter system. The dose variation due to field width was measured in each field segment width. The variation in attenuation of the compensators was measured as a function of filter position. As the field width increases, the relative absorbed dose also increases; this is the point of requiring compensation, so it can be in reverse proportion. Results: As the field width increases, the relative absorbed dose also increases; this is why compensation is required and thus it must be in reverse proportion. Attenuation of the absorbed dose by the paired filters was in proportion to the filter position. The filter position to compensate for the difference of absorbed doses was defined by the square root of the field width. For a field varying in width from 4 to 16 cm, the variation in the absorbed dose across the field was reduced from 12% to 2.7%. Conclusion: This paired wedge filter system reduced absorbed dose variations across multileaf collimator shaped fields and can facilitate treatment planning in conformal therapy. (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  7. Optimum filter selection for Dual Energy X-ray Applications through Analytical Modeling

    International Nuclear Information System (INIS)

    Koukou, V; Martini, N; Sotiropoulou, P; Nikiforidis, G; Michail, C; Kalyvas, N; Kandarakis, I; Fountos, G

    2015-01-01

    In this simulation study, an analytical model was used in order to determine the optimal acquisition parameters for a dual energy breast imaging system. The modeled detector system, consisted of a 33.91mg/cm 2 Gd 2 O 2 S:Tb scintillator screen, placed in direct contact with a high resolution CMOS sensor. Tungsten anode X-ray spectra, filtered with various filter materials and filter thicknesses were examined for both the low- and high-energy beams, resulting in 3375 combinations. The selection of these filters was based on their K absorption edge (K-edge filtering). The calcification signal-to-noise ratio (SNR tc ) and the mean glandular dose (MGD) were calculated. The total mean glandular dose was constrained to be within acceptable levels. Optimization was based on the maximization of the SNR tc /MGD ratio. The results showed that the optimum spectral combination was 40kVp with added beam filtration of 100 μm Ag and 70kVp Cu filtered spectrum of 1000 μm for the low- and high-energy, respectively. The minimum detectable calcification size was 150 μm. Simulations demonstrate that this dual energy X-ray technique could enhance breast calcification detection. (paper)

  8. Design and control of hybrid active power filters

    CERN Document Server

    Lam, Chi-Seng

    2014-01-01

    Design and Control of Hybrid Active Power Filters presents an overview of the current quality problems and their compensators. To get a balance between the system cost and performance, hybrid active power filters (HAPFs) are valuable. The book presents the coverage of resonance phenomena prevention capability, filtering performance and system robustness analysis of HAPF; nonlinear inverter current slope characteristics and their linear operation region requirement analysis of the hysteresis PWM for the HAPF; minimum inverter capacity design procedure of HAPF, adaptive dc-link voltage controller for the HAPF and the real design example of a 220V 10kVA HAPF, in which the system performance analysis method, minimum dc voltage deduction concept and adaptive dc voltage idea can be further extended into the other active compensators, such as APF, static synchronous compensator STATCOM, etc. This book will benefit researchers, graduate students, and electrical power engineers in the field of power-quality compensati...

  9. Digital implementation of the preloaded filter pulse processor

    International Nuclear Information System (INIS)

    Westphal, G.P.; Cadek, G.R.; Keroe, N.; Sauter, TH.; Thorwartl, P.C.

    1995-01-01

    Adapting it's processing time to the respective pulse intervals, the Preloaded Filter (PLF) pulse processor offers optimum resolution together with highest possible throughput rates. The PLF algorithm could be formulated in a recursive manner which made possible it's implementation by means of a large field-programmable gate array, as a fast, pipe-lined digital processor with 10 MHz maximum throughput rate. While pre-filter digitization by an ADC with 12 bit resolution and 10M Hz sampling rate resulted in a poorer resolution than that of an analog filter, a digital PLF based on an ADC with 14 bit resolution and 10 MHz sampling rate, surpassed high-quality analog filters in resolution, throughput rate and long-term stability. (author) 6 refs.; 7 figs

  10. Experimental determination of the thickness of aluminum cascade pipes in the presence of UF{sub 6} gas during enrichment measurements

    Energy Technology Data Exchange (ETDEWEB)

    Lombardi, M.L., E-mail: lombardi@lanl.gov [Los Alamos National Laboratory, P.O. Box 1663, Los Alamos NM 87545 (United States); Favalli, A.; Goda, J.M.; Ianakiev, K.D.; MacArthur, D.W.; Moss, C.E. [Los Alamos National Laboratory, P.O. Box 1663, Los Alamos NM 87545 (United States)

    2012-04-21

    We present a method of determining the wall thickness of a pipe in a Gas Centrifuge Enrichment Plant (GCEP) when an empty pipe measurement is not feasible. Our method uses an X-ray tube for transmission measurements and a lanthanum bromide (LaBr{sub 3}) scintillation detector on the opposite side of the pipe. Two filters, molybdenum (K-edge 20.0 keV) and palladium (K-edge 24.35 keV) are used to transform the bremsstrahlung spectra produced by the X-ray tube into more useful, sharply peaked, spectra. The maximum energies of the peaks are determined by the K-edges of the filters. The attenuation properties of the uranium hexafluoride (UF{sub 6}) gas allow us to determine wall thickness by looking at the ratio of selected regions of interest (ROIs) of the Mo and Pd transmitted spectra. While the attenuation factor at these two transmission energies in the UF{sub 6} gas is nearly equal, attenuation in the aluminum pipe wall at these two energies differs by a factor of about 60. This difference allows measurement of attenuation in the pipe independent of attenuation in the UF{sub 6} gas. Feasibility studies were performed using analytical calculations, and filter thicknesses were optimized. In order to experimentally validate our attenuation measurement method, a UF{sub 6} source with variable enrichment and pipe thickness was built. We describe the experimental procedure used to verify our previous calculations and present recent results.

  11. Reversible wavelet filter banks with side informationless spatially adaptive low-pass filters

    Science.gov (United States)

    Abhayaratne, Charith

    2011-07-01

    Wavelet transforms that have an adaptive low-pass filter are useful in applications that require the signal singularities, sharp transitions, and image edges to be left intact in the low-pass signal. In scalable image coding, the spatial resolution scalability is achieved by reconstructing the low-pass signal subband, which corresponds to the desired resolution level, and discarding other high-frequency wavelet subbands. In such applications, it is vital to have low-pass subbands that are not affected by smoothing artifacts associated with low-pass filtering. We present the mathematical framework for achieving 1-D wavelet transforms that have a spatially adaptive low-pass filter (SALP) using the prediction-first lifting scheme. The adaptivity decisions are computed using the wavelet coefficients, and no bookkeeping is required for the perfect reconstruction. Then, 2-D wavelet transforms that have a spatially adaptive low-pass filter are designed by extending the 1-D SALP framework. Because the 2-D polyphase decompositions are used in this case, the 2-D adaptivity decisions are made nonseparable as opposed to the separable 2-D realization using 1-D transforms. We present examples using the 2-D 5/3 wavelet transform and their lossless image coding and scalable decoding performances in terms of quality and resolution scalability. The proposed 2-D-SALP scheme results in better performance compared to the existing adaptive update lifting schemes.

  12. Advanced configuration of hybrid passive filter for reactive power and harmonic compensation.

    Science.gov (United States)

    Kececioglu, O Fatih; Acikgoz, Hakan; Sekkeli, Mustafa

    2016-01-01

    Harmonics is one of the major power quality problems for power systems. The harmonics can be eliminated by power filters such as passive, active, and hybrid. In this study, a new passive filter configuration has been improved in addition to the existing passive filter configurations. Conventional hybrid passive filters are not successful to compensate rapidly changing reactive power demand. The proposed configure are capable of compensating both harmonics and reactive power at the same time. Simulation results show that performance of reactive power and harmonic compensation with advanced hybrid passive filter is better than conventional hybrid passive filters.

  13. The fluence research of filter material for fast neutron fluence measurement

    International Nuclear Information System (INIS)

    Tang Xiding

    2010-01-01

    When the fast neutron fluence is measured by radioactivation techniques in the nuclear reactor the fast neutron is also filtered a little by the thermal neutron filter material, and if the filter material thickness increase the filtered fast neutron increases therewith. For fast neutron fluenc measurement, there are only cadmium, boron and gadolinium three elements filtering fluence can be calculated ordinarily. In order to calculate the filtered fast neutron fluence of the all elements in the filter material, the many total cross sections of nuclides had checked out from nuclear cross section data library, converted them into the same energy group structure, then element's total cross section, compound's total cross section and multilayer filters' total cross section had calculated from these total cross sections with same energy group structure, a new cross section data library can be obtained lastly through merging these cross sections into the old cross section data library used for neutron fluence measurement. The calculation analysis indicates that the results of the unit 2 surveillance capsule U of DAYA Bay NPP and the unit 1 surveillance capsule A of the Second Nuclear Power Plant of Qinshan by considering the all elements subtracting iron are smaller about 1.5% and 2.6% respectively than the ones only to consider cadmium, boron. The old measured results accord with the new values under the measurement uncertainty, are reliable. The new results are more accuracy. (authors)

  14. Advanced configuration of hybrid passive filter for reactive power and harmonic compensation

    OpenAIRE

    Kececioglu, O. Fatih; Acikgoz, Hakan; Sekkeli, Mustafa

    2016-01-01

    Harmonics is one of the major power quality problems for power systems. The harmonics can be eliminated by power filters such as passive, active, and hybrid. In this study, a new passive filter configuration has been improved in addition to the existing passive filter configurations. Conventional hybrid passive filters are not successful to compensate rapidly changing reactive power demand. The proposed configure are capable of compensating both harmonics and reactive power at the same time. ...

  15. Tunnel magnetoresistance in double spin filter junctions

    International Nuclear Information System (INIS)

    Saffarzadeh, Alireza

    2003-01-01

    We consider a new type of magnetic tunnel junction, which consists of two ferromagnetic tunnel barriers acting as spin filters (SFs), separated by a nonmagnetic metal (NM) layer. Using the transfer matrix method and the free-electron approximation, the dependence of the tunnel magnetoresistance (TMR) on the thickness of the central NM layer, bias voltage and temperature in the double SF junction are studied theoretically. It is shown that the TMR and electron-spin polarization in this structure can reach very large values under suitable conditions. The highest value of the TMR can reach 99%. By an appropriate choice of the thickness of the central NM layer, the degree of spin polarization in this structure will be higher than that of the single SF junctions. These results may be useful in designing future spin-polarized tunnelling devices

  16. Manufacturing a low-cost ceramic water filter and filter system for the elimination of common pathogenic bacteria

    Science.gov (United States)

    Simonis, J. J.; Basson, A. K.

    Africa is one of the most water-scarce continents in the world but it is the lack of potable water which results in diarrhoea being the leading cause of death amongst children under the age of five in Africa (696 million children under 5 years old in Africa contract diarrhoea resulting in 2000 deaths per day: WHO and UNICEF, 2009). Most potable water treatment methods use bulk water treatment not suitable or available to the majority of rural poor in Sub-Saharan Africa. One simple but effective way of making sure that water is of good quality is by purifying it by means of a household ceramic water filter. The making and supply of water filters suitable for the removal of suspended solids, pathogenic bacteria and other toxins from drinking water is therefore critical. A micro-porous ceramic water filter with micron-sized pores was developed using the traditional slip casting process. This locally produced filter has the advantage of making use of less raw materials, cost, labour, energy and expertise and being more effective and efficient than other low cost produced filters. The filter is fitted with a silicone tube inserted into a collapsible bag that acts as container and protection for the filter. Enhanced flow is obtained through this filter system. The product was tested using water inoculated with high concentrations of different bacterial cultures as well as with locally polluted stream water. The filter is highly effective (log10 > 4 with 99.99% reduction efficiency) in providing protection from bacteria and suspended solids found in natural water. With correct cleaning and basic maintenance this filter technology can effectively provide drinking water to rural families affected by polluted surface water sources. This is an African solution for the more than 340 million people in Africa without access to clean drinking water (WHO and UNICEF, 2008).

  17. Retinal blood vessel extraction using tunable bandpass filter and fuzzy conditional entropy.

    Science.gov (United States)

    Sil Kar, Sudeshna; Maity, Santi P

    2016-09-01

    Extraction of blood vessels on retinal images plays a significant role for screening of different opthalmologic diseases. However, accurate extraction of the entire and individual type of vessel silhouette from the noisy images with poorly illuminated background is a complicated task. To this aim, an integrated system design platform is suggested in this work for vessel extraction using a sequential bandpass filter followed by fuzzy conditional entropy maximization on matched filter response. At first noise is eliminated from the image under consideration through curvelet based denoising. To include the fine details and the relatively less thick vessel structures, the image is passed through a bank of sequential bandpass filter structure optimized for contrast enhancement. Fuzzy conditional entropy on matched filter response is then maximized to find the set of multiple optimal thresholds to extract the different types of vessel silhouettes from the background. Differential Evolution algorithm is used to determine the optimal gain in bandpass filter and the combination of the fuzzy parameters. Using the multiple thresholds, retinal image is classified as the thick, the medium and the thin vessels including neovascularization. Performance evaluated on different publicly available retinal image databases shows that the proposed method is very efficient in identifying the diverse types of vessels. Proposed method is also efficient in extracting the abnormal and the thin blood vessels in pathological retinal images. The average values of true positive rate, false positive rate and accuracy offered by the method is 76.32%, 1.99% and 96.28%, respectively for the DRIVE database and 72.82%, 2.6% and 96.16%, respectively for the STARE database. Simulation results demonstrate that the proposed method outperforms the existing methods in detecting the various types of vessels and the neovascularization structures. The combination of curvelet transform and tunable bandpass

  18. Conversion of sand filters into activated carbon filters at the La Presa (Valencia) water works; Conversion de filtros de arena porcarbon activo en la ETAP de La Presa (Valencia)

    Energy Technology Data Exchange (ETDEWEB)

    Macian Cervera, V. J.; Monforte Monleon, L.; Ribera Orts, R.; Suris Jorda, J. I.; Klee, J. M.

    2007-07-01

    To improve the water quality at potable water treatment plant of La P esa (Valencia), the sand filters have been replaced for activated carbon filters. In the following review the results and conclusions of the direct sand filter conversion into activated carbon filters will be presented. The leads to a simple and fast solution to odour and taste removal, as well as dissolved organic matter, without investments in works at the water works. (Author)

  19. An improved filtering algorithm for big read datasets and its application to single-cell assembly.

    Science.gov (United States)

    Wedemeyer, Axel; Kliemann, Lasse; Srivastav, Anand; Schielke, Christian; Reusch, Thorsten B; Rosenstiel, Philip

    2017-07-03

    For single-cell or metagenomic sequencing projects, it is necessary to sequence with a very high mean coverage in order to make sure that all parts of the sample DNA get covered by the reads produced. This leads to huge datasets with lots of redundant data. A filtering of this data prior to assembly is advisable. Brown et al. (2012) presented the algorithm Diginorm for this purpose, which filters reads based on the abundance of their k-mers. We present Bignorm, a faster and quality-conscious read filtering algorithm. An important new algorithmic feature is the use of phred quality scores together with a detailed analysis of the k-mer counts to decide which reads to keep. We qualify and recommend parameters for our new read filtering algorithm. Guided by these parameters, we remove in terms of median 97.15% of the reads while keeping the mean phred score of the filtered dataset high. Using the SDAdes assembler, we produce assemblies of high quality from these filtered datasets in a fraction of the time needed for an assembly from the datasets filtered with Diginorm. We conclude that read filtering is a practical and efficient method for reducing read data and for speeding up the assembly process. This applies not only for single cell assembly, as shown in this paper, but also to other projects with high mean coverage datasets like metagenomic sequencing projects. Our Bignorm algorithm allows assemblies of competitive quality in comparison to Diginorm, while being much faster. Bignorm is available for download at https://git.informatik.uni-kiel.de/axw/Bignorm .

  20. Silver Nanoparticles (AgNP impregnated filters in drinking water disinfection

    Directory of Open Access Journals (Sweden)

    Rus Alexandru

    2017-01-01

    Full Text Available This paper describes how simple portable devices could eliminate water pathogens by using Silver Nanoparticles, based on their antimicrobial properties. Recent studies indicated that silver nanoparticles can achieve up to 100% antibacterial activity removal. Results are showing that Silver Nanoparticles retention in the filter structure, E. coli bacteria removal, water quality and water flow rate must be evaluated as main efficiency indicators of the designed filters, in order to obtain the optimal filter. To apply the antimicrobial property of Silver in drinking-water treatment, a filter is produced using Additive Manufacturing techniques and coated with different concentrations of silver solutions.

  1. Highly uniform residual layers for arrays of 3D nanoimprinted cavities in Fabry-Pérot-filter-array-based nanospectrometers

    Science.gov (United States)

    Memon, Imran; Shen, Yannan; Khan, Abdullah; Woidt, Carsten; Hillmer, Hartmut

    2016-04-01

    Miniaturized optical spectrometers can be implemented by an array of Fabry-Pérot (FP) filters. FP filters are composed of two highly reflecting parallel mirrors and a resonance cavity. Each filter transmits a small spectral band (filter line) depending on its individual cavity height. The optical nanospectrometer, a miniaturized FP-based spectrometer, implements 3D NanoImprint technology for the fabrication of multiple FP filter cavities in a single process step. However, it is challenging to avoid the dependency of residual layer (RL) thickness on the shape of the printed patterns in NanoImprint. Since in a nanospectrometer the filter cavities vary in height between neighboring FP filters and, thus, the volume of each cavity varies causing that the RL varies slightly or noticeably between different filters. This is one of the few disadvantages of NanoImprint using soft templates such as substrate conformal imprint lithography which is used in this paper. The advantages of large area soft templates can be revealed substantially if the problem of laterally inhomogeneous RLs can be avoided or reduced considerably. In the case of the nanospectrometer, non-uniform RLs lead to random variations in the designed cavity heights resulting in the shift of desired filter lines. To achieve highly uniform RLs, we report a volume-equalized template design with the lateral distribution of 64 different cavity heights into several units with each unit comprising four cavity heights. The average volume of each unit is kept constant to obtain uniform filling of imprint material per unit area. The imprint results, based on the volume-equalized template, demonstrate highly uniform RLs of 110 nm thickness.

  2. Blended particle filters for large-dimensional chaotic dynamical systems

    Science.gov (United States)

    Majda, Andrew J.; Qi, Di; Sapsis, Themistoklis P.

    2014-01-01

    A major challenge in contemporary data science is the development of statistically accurate particle filters to capture non-Gaussian features in large-dimensional chaotic dynamical systems. Blended particle filters that capture non-Gaussian features in an adaptively evolving low-dimensional subspace through particles interacting with evolving Gaussian statistics on the remaining portion of phase space are introduced here. These blended particle filters are constructed in this paper through a mathematical formalism involving conditional Gaussian mixtures combined with statistically nonlinear forecast models compatible with this structure developed recently with high skill for uncertainty quantification. Stringent test cases for filtering involving the 40-dimensional Lorenz 96 model with a 5-dimensional adaptive subspace for nonlinear blended filtering in various turbulent regimes with at least nine positive Lyapunov exponents are used here. These cases demonstrate the high skill of the blended particle filter algorithms in capturing both highly non-Gaussian dynamical features as well as crucial nonlinear statistics for accurate filtering in extreme filtering regimes with sparse infrequent high-quality observations. The formalism developed here is also useful for multiscale filtering of turbulent systems and a simple application is sketched below. PMID:24825886

  3. Comparison of Deconvolution Filters for Photoacoustic Tomography.

    Directory of Open Access Journals (Sweden)

    Dominique Van de Sompel

    Full Text Available In this work, we compare the merits of three temporal data deconvolution methods for use in the filtered backprojection algorithm for photoacoustic tomography (PAT. We evaluate the standard Fourier division technique, the Wiener deconvolution filter, and a Tikhonov L-2 norm regularized matrix inversion method. Our experiments were carried out on subjects of various appearances, namely a pencil lead, two man-made phantoms, an in vivo subcutaneous mouse tumor model, and a perfused and excised mouse brain. All subjects were scanned using an imaging system with a rotatable hemispherical bowl, into which 128 ultrasound transducer elements were embedded in a spiral pattern. We characterized the frequency response of each deconvolution method, compared the final image quality achieved by each deconvolution technique, and evaluated each method's robustness to noise. The frequency response was quantified by measuring the accuracy with which each filter recovered the ideal flat frequency spectrum of an experimentally measured impulse response. Image quality under the various scenarios was quantified by computing noise versus resolution curves for a point source phantom, as well as the full width at half maximum (FWHM and contrast-to-noise ratio (CNR of selected image features such as dots and linear structures in additional imaging subjects. It was found that the Tikhonov filter yielded the most accurate balance of lower and higher frequency content (as measured by comparing the spectra of deconvolved impulse response signals to the ideal flat frequency spectrum, achieved a competitive image resolution and contrast-to-noise ratio, and yielded the greatest robustness to noise. While the Wiener filter achieved a similar image resolution, it tended to underrepresent the lower frequency content of the deconvolved signals, and hence of the reconstructed images after backprojection. In addition, its robustness to noise was poorer than that of the Tikhonov

  4. Filtering Water by Use of Ultrasonically Vibrated Nanotubes

    Science.gov (United States)

    Gavalas, Lillian Susan

    2009-01-01

    Devices that could be characterized as acoustically driven molecular sieves have been proposed for filtering water to remove all biological contaminants and all molecules larger than water molecules. Originally intended for purifying wastewater for reuse aboard spacecraft, these devices could also be attractive for use on Earth in numerous settings in which there are requirements to obtain potable, medical-grade, or otherwise pure water from contaminated water supplies. These devices could also serve as efficient means of removing some or all water from chemical products . for example, they might be useful as adjuncts or substitutes for stills in the removal of water from alcohols and alcoholic beverages. These devices may be constructed using various materials, such as ceramics, metallics, or polymers, depending on end-use requirements. A representative device of this type (see figure) would include a polymeric disk, about 1 mm in diameter and between 1 and 40 microns thick, within which would be embedded single-wall carbon nanotubes aligned along the thickness axis. The polymeric disk would be part of a unitary polymeric ring assembly. An acoustic transducer in the form of a piezoelectric-film-and-electrode subassembly - typically 9 microns thick and made of poly(vinylidene fluoride) coated with copper 150 nm thick -. would be affixed to the outside of the outer polymeric ring by means of an electrically nonconductive epoxy. The nanotubes would be chosen to have diameters between about 8 and about 13.5 A because water molecules could fit into the nanotubes, but larger molecules could not. Water to be purified would be placed in contact with one face (typically, the upper face) of the filter disk. The surface tension of water is low enough that water molecules should enter and travel along the nanotubes, and computational simulations of molecular dynamics and experimental measurements have shown that the water molecules inside the nanotubes in this size range can

  5. Magnetic filtered plasma deposition and implantation technique

    CERN Document Server

    Zhang Hui Xing; Wu Xian Ying

    2002-01-01

    A high dense metal plasma can be produced by using cathodic vacuum arc discharge technique. The microparticles emitted from the cathode in the metal plasma can be removed when the metal plasma passes through the magnetic filter. It is a new technique for making high quality, fine and close thin films which have very widespread applications. The authors describe the applications of cathodic vacuum arc technique, and then a filtered plasma deposition and ion implantation system as well as its applications

  6. Washable antimicrobial polyester/aluminum air filter with a high capture efficiency and low pressure drop.

    Science.gov (United States)

    Choi, Dong Yun; Heo, Ki Joon; Kang, Juhee; An, Eun Jeong; Jung, Soo-Ho; Lee, Byung Uk; Lee, Hye Moon; Jung, Jae Hee

    2018-06-05

    Here, we introduce a reusable bifunctional polyester/aluminum (PET/Al) air filter for the high efficiency simultaneous capture and inactivation of airborne microorganisms. Both bacteria of Escherichia coli and Staphylococcus epidermidis were collected on the PET/Al filter with a high efficiency rate (∼99.99%) via the electrostatic interactions between the charged bacteria and fibers without sacrificing pressure drop. The PET/Al filter experienced a pressure drop approximately 10 times lower per thickness compared with a commercial high-efficiency particulate air filter. As the Al nanograins grew on the fibers, the antimicrobial activity against airborne E. coli and S. epidermidis improved to ∼94.8% and ∼96.9%, respectively, due to the reinforced hydrophobicity and surface roughness of the filter. Moreover, the capture and antimicrobial performances were stably maintained during a cyclic washing test of the PET/Al filter, indicative of its reusability. The PET/Al filter shows great potential for use in energy-efficient bioaerosol control systems suitable for indoor environments. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Characteristics of poly- and mono-crystalline BeO and SiO2 as thermal and cold neutron filters

    Science.gov (United States)

    Adib, M.; Habib, N.; Bashter, I. I.; Morcos, H. N.; El-Mesiry, M. S.; Mansy, M. S.

    2015-09-01

    A simple model along with a computer code "HEXA-FILTERS" is used to carry out the calculation of the total cross-sections of BeO and SiO2 having poly or mono-crystalline form as a function of neutron wavelength at room (R.T.) and liquid nitrogen (L.N.) temperatures. An overall agreement is indicated between the calculated neutron cross-sections and experimental data. Calculation shows that 25 cm thick of polycrystalline BeO cooled at liquid nitrogen temperature was found to be a good filter for neutron wavelengths longer than 0.46 nm. While, 50 cm of SiO2, with much less transmission, for neutrons with wavelengths longer than 0.85 nm. It was also found that 10 cm of BeO and 15 cm SiO2 thick mono-crystals cut along their (0 0 2) plane, with 0.5° FWHM on mosaic spread and cooled at L.N., are a good thermal neutron filter, with high effect-to-noise ratio.

  8. High-Q microwave photonic filter with a tuned modulator.

    Science.gov (United States)

    Capmany, J; Mora, J; Ortega, B; Pastor, D

    2005-09-01

    We propose the use of tuned electro-optic or electroabsorption external modulators to implement high-quality (high-Q) factor, single-bandpass photonic filters for microwave signals. Using this approach, we experimentally demonstrate a transversal finite impulse response with a Q factor of 237. This is to our knowledge the highest value ever reported for a passive finite impulse-response microwave photonic filter.

  9. Structural Shielding Design of a 6 MV Flattening Filter Free Linear Accelerator: Indian Scenario.

    Science.gov (United States)

    Mishra, Bibekananda; Selvam, T Palani; Sharma, P K Dash

    2017-01-01

    Detailed structural shielding of primary and secondary barriers for a 6 MV medical linear accelerator (LINAC) operated with flattening filter (FF) and flattening filter free (FFF) modes are calculated. The calculations have been carried out by two methods, one using the approach given in National Council on Radiation Protection (NCRP) Report No. 151 and the other based on the monitor units (MUs) delivered in clinical practice. Radiation survey of the installations was also carried out. NCRP approach suggests that the primary and secondary barrier thicknesses are higher by 24% and 26%. respectively, for a LINAC operated in FF mode to that of a LINAC operated in both FF and FFF modes with an assumption that only 20% of the workload is shared in FFF mode. Primary and secondary barrier thicknesses calculated from MUs delivered on clinical practice method also show the same trend and are higher by 20% and 19%, respectively, for a LINAC operated in FF mode to that of a LINAC operated in both FF and FFF modes. Overall, the barrier thickness for a LINAC operated in FF mode is higher about 20% to that of a LINAC operated in both FF and FFF modes.

  10. Synthesis of Cascadable DDCC-Based Universal Filter Using NAM

    Directory of Open Access Journals (Sweden)

    Huu-Duy Tran

    2015-08-01

    Full Text Available A novel systematic approach for synthesizing DDCC-based voltage-mode biquadratic universal filters is proposed. The DDCCs are described by infinity-variables’ models of nullor-mirror elements which can be used in the nodal admittance matrix expansion process. Applying the proposed method, the obtained 12 equivalent filters offer the following features: multi-input and two outputs, realization of all five standard filter functions, namely lowpass, bandpass, highpass, notch and allpass, high-input impedance, employing only grounded capacitors and resistors, orthogonal controllability between pole frequency and quality factor, and cascadable, low active and passive sensitivities. The workability of some synthesized filters is verified by HSPICE simulations to demonstrate the feasibility of the proposed method.

  11. Quality-aware features-based noise level estimator for block matching and three-dimensional filtering algorithm

    Science.gov (United States)

    Xu, Shaoping; Hu, Lingyan; Yang, Xiaohui

    2016-01-01

    The performance of conventional denoising algorithms is usually controlled by one or several parameters whose optimal settings depend on the contents of the processed images and the characteristics of the noises. Among these parameters, noise level is a fundamental parameter that is always assumed to be known by most of the existing denoising algorithms (so-called nonblind denoising algorithms), which largely limits the applicability of these nonblind denoising algorithms in many applications. Moreover, these nonblind algorithms do not always achieve the best denoised images in visual quality even when fed with the actual noise level parameter. To address these shortcomings, in this paper we propose a new quality-aware features-based noise level estimator (NLE), which consists of quality-aware features extraction and optimal noise level parameter prediction. First, considering that image local contrast features convey important structural information that is closely related to image perceptual quality, we utilize the marginal statistics of two local contrast operators, i.e., the gradient magnitude and the Laplacian of Gaussian (LOG), to extract quality-aware features. The proposed quality-aware features have very low computational complexity, making them well suited for time-constrained applications. Then we propose a learning-based framework where the noise level parameter is estimated based on the quality-aware features. Based on the proposed NLE, we develop a blind block matching and three-dimensional filtering (BBM3D) denoising algorithm which is capable of effectively removing additive white Gaussian noise, even coupled with impulse noise. The noise level parameter of the BBM3D algorithm is automatically tuned according to the quality-aware features, guaranteeing the best performance. As such, the classical block matching and three-dimensional algorithm can be transformed into a blind one in an unsupervised manner. Experimental results demonstrate that the

  12. An assessment of filter aids and filter cloths in the dewatering of intermediate level wastes

    International Nuclear Information System (INIS)

    Knibbs, R.H.; Hudson, B.C.; Blackwell, J.C.W.

    1984-12-01

    This report considers a range of filter cloths and precoat materials intended for use in dewatering intermediate level radioactive wastes, and their interaction when used on a rotary drum vacuum filter. The report outlines the advantages and disadvantages of various grades and types of precoat and shows that grades with permeabilities in the intermediate range, 3 to 4 x 10 -12 m 2 , give satisfactory filtrate quality together with ease of operation. The work on filter cloths shows that: radiation damage is not a limiting factor as regards operational life for any of the cloths examined; polyester-based cloths are unsuitable due to their poor resistance to alkali attack; polyamide cloths are satisfactory; and stainless steel Dutch weave cloths are satisfactory and have the added advantage of high strength. The report also briefly considers the radiation resistance of two elastomeric membranes used on the 'epidermal' filter and shows that the natural latex rubber membrane is considerably more resistant to radiation than the silicone rubber membrane and has an estimated operational life of at least 1200 hours when dewatering Magnox silo sludge or α-contaminated alumino ferric flocs. (author)

  13. Ultrafast all-optical clock recovery based on phase-only linear optical filtering

    DEFF Research Database (Denmark)

    Maram, Reza; Kong, Deming; Galili, Michael

    2014-01-01

    We report on a novel technique for all-optical clock recovery from RZ OOK data based on phase-only filtering, significantly enhancing the recovered clock quality and energy-efficiency compared to the use of a Fabry-Perot filter....

  14. Plasmonic coaxial Fabry-Pérot nanocavity color filter

    Science.gov (United States)

    Si, G. Y.; Leong, E. S. P.; Danner, A. J.; Teng, J. H.

    2010-08-01

    Plamonic coaxial structures have drawn considerable attetion recently because of their unique properties. They exhibit different mechanisms of extraordinary optical transmission observed from subwavelength holes and they can support localized Fabry-Pérot plasmon modes. In this work, we experimentally demonstrate color filters based on coaxial structures fabricated in optically thick metallic films. Using nanogaps with different apertures from 160 nm down to only 40 nm, we show varying color outputs when the annular aperture arrays are illuminated with a broadband light source. Effective color-filter function is demonstrated in the optical regime. Different color outputs are observed and optical spectra are measured. In such structures, it is the propagating mode playing an important role rather than the evanescent. Resonances depend strongly on ring apertures, enabling devices with tunability of output colors using simple geometry control.

  15. Determination of optimum filter in inferolateral view of myocardial SPECT

    International Nuclear Information System (INIS)

    Takavar; Eftekhari, M.; Fallahi, B.; Shamsipour, Gh.; Sohrabi, M.; Saghari, M.

    2004-01-01

    Background: In myocardial perfusion SPECT imaging, images are degraded by photon attenuation, distance-dependent collimator, detector response and photon scattering. As filters greatly affect quality of nuclear medicine images, in this study determination of optimum filter for inferolateral view is our prime objective. Materials and Methods: .A phantom simulating heart left ventricle was built. About 1mCi of 99m Tc, was injected into the phantom. Images were taken from this phantom. Parzen, Hamming, Hanning, Butter worth and Gaussian filters were exerted on the images obtained from the phantom.. By defining some criteria such as contrast, signal to noise ratio, and defect size delectability, the best filter was determined for our ADAC spect system at our nuclear medicine center. In this study, 27 patients who previously had undergone coronary angiography were chosen to be included. All of these patients revealed significant stenosis in the left circumflex artery. Myocardial SPECT images of these patients had inferolateral defect. The images of these patients were processed with 12 filters including the optimum filters obtained from phantom study and some other non-optimum filters. A nuclear medicine physician quantified the results by assigmng mark from 0 to 4. to every image. 0 mark for images that didn't show the defect properly and 4 for the best one. The data from patient study were analyzed with non-related, non -parametric Friedman test. Results: Nyquist frequency of 0.325 and 0.5 were obtained as the optimum cut-off frequencies for hamming and Hanning filters respectively. Order 11 and cut-off frequency of 0.45 and order 20. with cut-off frequency of 0.5 were found to be optimum for Butter worth and Gaussian filters. In patient studies it was found that, Butter worth filter with cut-off frequency of 0.45 and order of 11 produced the best quality images. Conclusion: In this study. Butter worth filter with cut-off frequency of 0.45 and order of 11 was the

  16. Filters in 2D and 3D Cardiac SPECT Image Processing

    Directory of Open Access Journals (Sweden)

    Maria Lyra

    2014-01-01

    Full Text Available Nuclear cardiac imaging is a noninvasive, sensitive method providing information on cardiac structure and physiology. Single photon emission tomography (SPECT evaluates myocardial perfusion, viability, and function and is widely used in clinical routine. The quality of the tomographic image is a key for accurate diagnosis. Image filtering, a mathematical processing, compensates for loss of detail in an image while reducing image noise, and it can improve the image resolution and limit the degradation of the image. SPECT images are then reconstructed, either by filter back projection (FBP analytical technique or iteratively, by algebraic methods. The aim of this study is to review filters in cardiac 2D, 3D, and 4D SPECT applications and how these affect the image quality mirroring the diagnostic accuracy of SPECT images. Several filters, including the Hanning, Butterworth, and Parzen filters, were evaluated in combination with the two reconstruction methods as well as with a specified MatLab program. Results showed that for both 3D and 4D cardiac SPECT the Butterworth filter, for different critical frequencies and orders, produced the best results. Between the two reconstruction methods, the iterative one might be more appropriate for cardiac SPECT, since it improves lesion detectability due to the significant improvement of image contrast.

  17. Event filter monitoring with the ATLAS tile calorimeter

    CERN Document Server

    Fiorini, L

    2008-01-01

    The ATLAS Tile Calorimeter detector is presently involved in an intense phase of subsystems integration and commissioning with muons of cosmic origin. Various monitoring programs have been developed at different levels of the data flow to tune the set-up of the detector running conditions and to provide a fast and reliable assessment of the data quality already during data taking. This paper focuses on the monitoring system integrated in the highest level of the ATLAS trigger system, the Event Filter, and its deployment during the Tile Calorimeter commissioning with cosmic ray muons. The key feature of Event Filter monitoring is the capability of performing detector and data quality control on complete physics events at the trigger level, hence before events are stored on disk. In ATLAS' online data flow, this is the only monitoring system capable of giving a comprehensive event quality feedback.

  18. Chip-scale fluorescence microscope based on a silo-filter complementary metal-oxide semiconductor image sensor.

    Science.gov (United States)

    Ah Lee, Seung; Ou, Xiaoze; Lee, J Eugene; Yang, Changhuei

    2013-06-01

    We demonstrate a silo-filter (SF) complementary metal-oxide semiconductor (CMOS) image sensor for a chip-scale fluorescence microscope. The extruded pixel design with metal walls between neighboring pixels guides fluorescence emission through the thick absorptive filter to the photodiode of a pixel. Our prototype device achieves 13 μm resolution over a wide field of view (4.8 mm × 4.4 mm). We demonstrate bright-field and fluorescence longitudinal imaging of living cells in a compact, low-cost configuration.

  19. Study of SNS and SIS NbN Josephson junctions coupled to a microwave band-pass filter

    Energy Technology Data Exchange (ETDEWEB)

    Baggetta, E; Setzu, R; Villegier, J C [Laboratoire de Cryophysique, DRFMC, CEA, Grenoble (France)

    2006-06-01

    We have fabricated both NbN/Ta{sub x}N/NbN SN*S-type, NbN/MgO/NbN SIS-type Josephson junctions and microwave band-pass filters on different substrates (Si, Sapphire, MgO). NbN films have been deposited on both sides of (100) oriented, 250 {mu}m thick, MgO substrates with a high crystalline texture quality. The aim was to investigate the performances and the maximum achievable operating frequency in an NbN based RSFQ modulator front-end of an ADC in the 4 K-10 K temperature range. We observed that Ta{sub x}N thin films can be tuned from an insulating phase to a superconducting phase (Tc {approx}4K) by varying the nitrogen content during sputter deposition while the barrier height of MgO can also be controlled by deposition conditions and by tri-layer postdeposition annealing. Junction properties (Jc{approx}10-25 kA/cm{sup 2}), Mac Cumber parameter and RnIc product measured up to 1 mV are shown to be controlled by the reactive sputtering conditions. We have designed three pole band-pass filters and resonators in a micro-strip configuration and studied the junction coupling with the filters. We will show that a sigma-delta NbN technology is a suitable solution for analogue-to-digital conversion in the future generations of telecommunication satellites to achieve high sampling frequency and large bandwidth at high carrier frequency signal.

  20. Study of SNS and SIS NbN Josephson junctions coupled to a microwave band-pass filter

    International Nuclear Information System (INIS)

    Baggetta, E; Setzu, R; Villegier, J C

    2006-01-01

    We have fabricated both NbN/Ta x N/NbN SN*S-type, NbN/MgO/NbN SIS-type Josephson junctions and microwave band-pass filters on different substrates (Si, Sapphire, MgO). NbN films have been deposited on both sides of (100) oriented, 250 μm thick, MgO substrates with a high crystalline texture quality. The aim was to investigate the performances and the maximum achievable operating frequency in an NbN based RSFQ modulator front-end of an ADC in the 4 K-10 K temperature range. We observed that Ta x N thin films can be tuned from an insulating phase to a superconducting phase (Tc ∼4K) by varying the nitrogen content during sputter deposition while the barrier height of MgO can also be controlled by deposition conditions and by tri-layer postdeposition annealing. Junction properties (Jc∼10-25 kA/cm 2 ), Mac Cumber parameter and RnIc product measured up to 1 mV are shown to be controlled by the reactive sputtering conditions. We have designed three pole band-pass filters and resonators in a micro-strip configuration and studied the junction coupling with the filters. We will show that a sigma-delta NbN technology is a suitable solution for analogue-to-digital conversion in the future generations of telecommunication satellites to achieve high sampling frequency and large bandwidth at high carrier frequency signal

  1. Filter arrays

    Science.gov (United States)

    Page, Ralph H.; Doty, Patrick F.

    2017-08-01

    The various technologies presented herein relate to a tiled filter array that can be used in connection with performance of spatial sampling of optical signals. The filter array comprises filter tiles, wherein a first plurality of filter tiles are formed from a first material, the first material being configured such that only photons having wavelengths in a first wavelength band pass therethrough. A second plurality of filter tiles is formed from a second material, the second material being configured such that only photons having wavelengths in a second wavelength band pass therethrough. The first plurality of filter tiles and the second plurality of filter tiles can be interspersed to form the filter array comprising an alternating arrangement of first filter tiles and second filter tiles.

  2. Spectral shaping of an all-fiber torsional acousto-optic tunable filter.

    Science.gov (United States)

    Ko, Jeakwon; Lee, Kwang Jo; Kim, Byoung Yoon

    2014-12-20

    Spectral shaping of an all-fiber torsional acousto-optic (AO) tunable filter is studied. The technique is based on the axial modulation of AO coupling strength along a highly birefringent optical fiber, which is achieved by tailoring the outer diameter of the fiber along its propagation axis. Two kinds of filter spectral shaping schemes-Gaussian apodization and matched filtering with triple resonance peaks-are proposed and numerically investigated under realistic experimental conditions: at the 50-cm-long AO interaction length of the fiber and at half of the original fiber diameter as the minimum thickness of the tailored fiber section. The results show that the highest peak of sidelobe spectra in filter transmission is suppressed from 11.64% to 0.54% via Gaussian modulation of the AO coupling coefficient (κ). Matched filtering with triple resonance peaks operating with a single radio frequency signal is also achieved by cosine modulation of κ, of which the modulation period determines the spectral distance between two satellite peaks located in both wings of the main resonance peak. The splitting of two satellite peaks in the filter spectra reaches 48.2 nm while the modulation period varies from 7.7 to 50 cm. The overall peak power of two satellite resonances is calculated to be 22% of the main resonance power. The results confirm the validity and practicality of our approach, and we predict robust and stable operation of the designed all-fiber torsional AO filters.

  3. Macular thickness after glaucoma filtration surgery.

    Science.gov (United States)

    Sesar, Antonio; Cavar, Ivan; Sesar, Anita Pusić; Geber, Mia Zorić; Sesar, Irena; Laus, Katia Novak; Vatavuk, Zoran; Mandić, Zdravko

    2013-09-01

    The aim of present study was to analyze early postoperative changes in the macular area using optical coherence tomography (OCT) after uncomplicated glaucoma filtration surgery. This prospective study included 32 patients (34 eyes) with open-angle glaucoma, which underwent trabeculectomy with or without use of mitomycin C. Exclusion criteria were macular edema, uveitis, age-related macular degeneration, blurred optical media, secondary glaucoma and angle-closure glaucoma. All standard clinical examinations were made before surgery, at the 2nd day, 1 week and 1 month after surgery. Tomography of the macula was performed during every examination using Cirrus HD OCT for the analysis of central subfield thickness. Results show that thickening of the macula was slightly higher 1 week and 1 month after operation in comparison with baseline end 2nd day postoperativelly. There was no significant difference in the change of macular thickness in patients who have used topical prostaglandins compared with those who have used other topical medications. Also, there was no difference in macular changes between patients treated with or without mitomycin C. In conclusion, we found a slight subclinical increase in macular thickness after uncomplicated trabeculectomy, for which we considered that was the result in reduction of intraocular pressure after glaucoma surgery. Macular thickening after glaucoma filtering surgery could be a physiological reaction to the stress of the retina caused by a sudden reduction of intraocular pressure and it is the consequence of altered relationship between capillary pressure and interstitial fluid pressure.

  4. Pyrolytic graphite as an efficient second-order neutron filter at tuned positions of boundary crossing

    International Nuclear Information System (INIS)

    Adib, M.; Abdel Kawy, A.; Habib, N.; El Mesiry, M.

    2010-01-01

    An investigation of pyrolytic graphite (PG) crystal as an efficient second order neutron filter at tuned boundary crossings has been carried out. The neutron transmission through PG crystal at these tuned crossing points as a function of first- and second-order wavelengths were calculated in terms of PG mosaic spread and thickness. The filtering features of PG crystals at these tuned boundary crossings were deduced. It was shown that, there are a large number of tuned positions at double and triple boundary crossings of the curves (hkl) are very promising as tuned filter positions. However, only fourteen of them are found to be most promising ones. These tuned positions are found to be within the neutron wavelengths from 0.133 up to 0.4050 nm. A computer package GRAPHITE has been used in order to provide the required calculations in the whole neutron wavelength range in terms of PG mosaic spread and its orientation with respect to incident neutron beam direction. It was shown that 0.5 cm thick PG crystal with angular mosaic spread of 2 0 is sufficient to remove 2nd-order neutrons at the wavelengths corresponding to the positions of the intersection boundaries curves (hkl).

  5. Comparative study of the parameters associated with quality control and absorbed dose in linear accelerators with (FF) and without (FFF) flattening filter

    International Nuclear Information System (INIS)

    Souza, Anderson Sorgatti de

    2017-01-01

    Teletherapy, radiation therapy with linear accelerators, for cancer treatment has being used for years with good clinical results.Since the 90's the removal of the flattening filter, item placed at the gantry of the machine, has shown better results for the treatment of some cancers thus being extensively studied. Treatments with Intensity Modulated Radiotherapy (IMRT) and Stereotaxic Radiotherapy (SRT) were more efficient without the flattening filter. Varian Oncology released the TrueBeam in 2012, a accelerator capable of operating with or without the flattening filter. The aim of this work is to access homogeneity of the percentage depth dose (PDP) and beam quality index (TPR20/10), two important parameters used in patient dose calculations. The data used for analysis were obtained with the Israelita Albert Einstein Hospital (HIAE), Real Portugues Hospital (RHP) and 3 more institutions located in the United States. The statistical data analysis allowed to observe the parameters behaviors. In general, they were very homogeneous, with errors smaller than 1% confirming the conformance of the TrueBeam accelerators. (author)

  6. Removal of Heavy Metals from Synthesis Industrial Wastewater Using Local Isolated Candida Utilis and Aspergillus Niger as Bio-Filter

    OpenAIRE

    Safaa Abd Alrasool Ali

    2013-01-01

    In this study biomass filter of Candida Utilis which isolated from food sample in Baghdad local market and Aspergillus Niger which isolated from Baghdad soil used to biosorption heavy metals from synthesis industrial wastewater. two bio-filters were designed as cylindrical Perspex with height 10cm, diameter 3cm as a shell and inside their are layers of Sponge were prepare as the size of diameter of the cylindrical filter with thickness of 2cm arrange inside it, biomass production were 6 g of ...

  7. A novel 2nd-order bandpass MFSS filter with miniaturized structure

    Directory of Open Access Journals (Sweden)

    C. Y. Fang

    2015-08-01

    Full Text Available In order to effectively obtain a miniaturized structure and good filtering properties, we propose a novel 2nd-order bandpass metamaterial frequency selective surface (MFSS filter which contains two capacitive layers and one inductive layer, where there are multi-loop metallic patches as shunt capacitor C and planar wire grids as series inductor L respectively. Unlike the traditional operation way—the tuned elements used in resonant surface approximately equal to one wavelength in circumference and the structure thickness with a spacing of a quarter wavelength apart, by changing the value of L and C and matching multilayer dielectric to adjust the LC coupling resonance and the resonance impedance respectively, the proposed MFSS filter can achieves a miniatured structure with ideal bandpass properties. Measurement results of the fabricated prototype of the bandpass filter (BPF indicate that the dimension of the tuned element on resonant surface is approximately 0.025 wavelength, i.e., 0.025λ. At the same time, the filter has the stable center frequency of f0 = 1.53GHz and the transmittance of T ⩾ 96.3% and high Q-value for the TE/TM wave polarization at various incidence angles. The novel 2nd-order bandpass MFSS filter with miniaturized structure not only can decrease structure dimension, but also has a wide range of applications to microwave and infrared band.

  8. Effects of closed immersion filtered water flow velocity on the ablation threshold of bisphenol A polycarbonate during excimer laser machining

    International Nuclear Information System (INIS)

    Dowding, Colin; Lawrence, Jonathan

    2010-01-01

    A closed flowing thick film filtered water immersion technique ensures a controlled geometry for both the optical interfaces of the flowing liquid film and allows repeatable control of flow-rate during machining. This has the action of preventing splashing, ensures repeatable machining conditions and allows control of liquid flow velocity. To investigate the impact of this technique on ablation threshold, bisphenol A polycarbonate samples have been machined using KrF excimer laser radiation passing through a medium of filtered water flowing at a number of flow velocities, that are controllable by modifying the liquid flow-rates. An average decrease in ablation threshold of 7.5% when using turbulent flow velocity regime closed thick film filtered water immersed ablation, compared to ablation using a similar beam in ambient air; however, the use of laminar flow velocities resulted in negligible differences between closed flowing thick film filtered water immersion and ambient air. Plotting the recorded threshold fluence achieved with varying flow velocity showed that an optimum flow velocity of 3.00 m/s existed which yielded a minimum ablation threshold of 112 mJ/cm 2 . This is attributed to the distortion of the ablation plume effected by the flowing immersion fluid changing the ablation mechanism: at laminar flow velocities Bremsstrahlung attenuation decreases etch rate, at excessive flow velocities the plume is completely destroyed, removing the effect of plume etching. Laminar flow velocity regime ablation is limited by slow removal of debris causing a non-linear etch rate over 'n' pulses which is a result of debris produced by one pulse remaining suspended over the feature for the next pulse. The impact of closed thick film filtered water immersed ablation is dependant upon beam fluence: high fluence beams achieved greater etch efficiency at high flow velocities as the effect of Bremsstrahlung attenuation is removed by the action of the fluid on the plume; low

  9. Design of photon energy compensation filters for the new four element CaSO4:Dy TLD badge

    International Nuclear Information System (INIS)

    Mishra, D.R.; Kulkarni, M.S.; Pradeep, Ratna; Kannan, S.

    2001-01-01

    A new four element TLD badge using CaSO 4 :Dy is being developed for the estimation of personal dose equivalents Hp(10) and Hp(0.07) and to discriminate them in the mix field (low energy x-ray and high energy γ-ray). Design of energy compensation filters for the new TLD badge is discussed. The total metal filter thickness is kept less than 1 mm. The first and second elements of the badge are planned to be open and plastic (≅180 gm/cm 2 ) window. For the third element a combination of 0.2 mm Sn + 0.7mm Cu + 0.1 mm Al with mass thickness ≅ 1100 mg/cm 2 is proposed which gives energy dependent response similar to Hp(10) within ± 20% (above 80 keV). For the fourth dosimeter a filter combination of 0.4 mm Al + 0.07 mm Sn is proposed which gives Hp(10)xR response for diagnostic x-rays within ± 10% in the mix field. (author)

  10. Evaluation of the composition of filters additional of equipment radiological intraoral by energy dispersive x-ray fluorescence (EDXRF)

    International Nuclear Information System (INIS)

    Franca, Alana Caroline; Torres, Catarina A.M.P.; Rocha, Ana S.S.; Deniak, Valeriy; Lara, Alessandro L.; Paschuk, Sergei A.; Fernandes, Angela; Westphalen, Fernando Henrique

    2013-01-01

    The need for high quality standards for radiographic images in order to make a diagnosis assertive, and being the additional filtration required in the intraoral X-ray equipment show the need of evaluating these filters. This study aims to examine the influence of the elemental composition of the filters of X-ray of dental intraoral equipment in the radiographic images quality. The filters analysis were performed by using the energy dispersive X-ray fluorescence method (EDXRF). Ten conventional filters were analysed. In this study, 33 radiographic exposures were performed using films: twenty radiographs in the incisor region and ten in the molar region, three exposures were also made in the same regions with same conditions without using filter. After radiographs development, optical density was measure and all radiographs were submitted to subjective evaluation by dental radiologists. Data obtained were correlated to effects evaluation of the elemental composition of all filters in the quality of the radiographic images. The elements found were: aluminum, cobalt, copper, sulfur, iron, manganese, titanium, zinc, and zirconium. The images obtained were identified in groups: Molars to 0.3 s; Incisors to 0.2 s; Incisors to 0.3 s, and for the group without filters. From the results obtained it was concluded that both unclear radiographs and ideal radiographs were produced by using filters of elementary common. Therefore, conventional filters evaluated were an acceptable option to produce quality images in dental radiology, despite differences in the composition of the alloys. (author)

  11. Evaluation of the composition of filters additional of equipment radiological intraoral by energy dispersive x-ray fluorescence (EDXRF)

    Energy Technology Data Exchange (ETDEWEB)

    Franca, Alana Caroline; Torres, Catarina A.M.P.; Rocha, Ana S.S.; Deniak, Valeriy; Lara, Alessandro L.; Paschuk, Sergei A., E-mail: alanacarolinef@gmail.com, E-mail: sergei@utfpr.edu.br [Universidade Tecnologica Federal do Parana (CPGEI/UTFPR), Curitiba, PR (Brazil). Programa de Pos-Graduacao em Engenharia Eletrica e Informatica Industrial; Fernandes, Angela; Westphalen, Fernando Henrique, E-mail: angelafernandes@ufpr.br [Universidade Federal do Parana (UFPR), Curitiba, PR (Brazil). Setor de Ciencias da Saude

    2013-07-01

    The need for high quality standards for radiographic images in order to make a diagnosis assertive, and being the additional filtration required in the intraoral X-ray equipment show the need of evaluating these filters. This study aims to examine the influence of the elemental composition of the filters of X-ray of dental intraoral equipment in the radiographic images quality. The filters analysis were performed by using the energy dispersive X-ray fluorescence method (EDXRF). Ten conventional filters were analysed. In this study, 33 radiographic exposures were performed using films: twenty radiographs in the incisor region and ten in the molar region, three exposures were also made in the same regions with same conditions without using filter. After radiographs development, optical density was measure and all radiographs were submitted to subjective evaluation by dental radiologists. Data obtained were correlated to effects evaluation of the elemental composition of all filters in the quality of the radiographic images. The elements found were: aluminum, cobalt, copper, sulfur, iron, manganese, titanium, zinc, and zirconium. The images obtained were identified in groups: Molars to 0.3 s; Incisors to 0.2 s; Incisors to 0.3 s, and for the group without filters. From the results obtained it was concluded that both unclear radiographs and ideal radiographs were produced by using filters of elementary common. Therefore, conventional filters evaluated were an acceptable option to produce quality images in dental radiology, despite differences in the composition of the alloys. (author)

  12. Ultra-compact microwave filters using kinetic inductance microstrip

    International Nuclear Information System (INIS)

    Pond, J.M.; Carroll, K.R.; Cukauskas, E.J.

    1991-01-01

    This paper reports on multi-pole microwave filters designed and fabricated using microstrip transmission line sections which consist of two very thin films of sputtered niobium nitride (NbN) separated by another very thin film of sputtered Si. Since the thicknesses of all three films are much less than the superconducting penetration depth, the kinetic inductance is significantly greater than the magnetic inductance. As a result, the phase velocity of a microstrip transmission line is much less than the free space speed of light. Since resonant structures are reduced in size proportionately, the size and weight of microstrip circuits can be greatly reduced. Prototype filters consisting of four open circuit half-wavelength microstrip stubs separated by full-wavelength microstrip sections have been measured. The circuits are connected to 34 mil diameter coaxial cable via an intermediate coplanar waveguide section. Passbands of 4 GHz separated by 3 GHz reject bands have been measured in a structure which occupies less than 0.5 cm 2 including the coplanar waveguide transitions. Higher-order passbands, although possessing an increased insertion loss, maintain filter passband characteristics through 20.0 GHz

  13. Design and fabrication of ultrathin silicon-nitride membranes for use in UV-visible airgap-based MEMS optical filters

    International Nuclear Information System (INIS)

    Ghaderi, Mohammadamir; Wolffenbuttel, Reinoud F.

    2016-01-01

    MEMS-based airgap optical filters are composed of quarter-wave thick high-index dielectric membranes that are separated by airgaps. The main challenge in the fabrication of these filters is the intertwined optical and mechanical requirements. The thickness of the layers decreases with design wavelength, which makes the optical performance in the UV more susceptible to fabrication tolerances, such as thickness and composition of the deposited layers, while the ability to sustain a certain level of residual stress by the structural strength becomes more critical. Silicon-nitride has a comparatively high Young's modulus and good optical properties, which makes it a suitable candidate as the membrane material. However, both the mechanical and optical properties in a silicon-nitride film strongly depend on the specifics of the deposition process. A design trade-off is required between the mechanical strength and the index of refraction, by tuning the silicon content in the silicon-nitride film. However, also the benefit of a high index of refraction in a silicon-rich film should be weighed against the increased UV optical absorption. This work presents the design, fabrication, and preliminary characterization of one and three quarter-wave thick silicon-nitride membranes with a one-quarter airgap and designed to give a spectral reflectance at 400 nm. The PECVD silicon-nitride layers were initially characterized, and the data was used for the optical and mechanical design of the airgap filters. A CMOS compatible process based on polysilicon sacrificial layers was used for the fabrication of the membranes. Optical characterization results are presented. (paper)

  14. Comparison of high efficiency particulate filter testing methods

    International Nuclear Information System (INIS)

    1985-01-01

    High Efficiency Particulate Air (HEPA) filters are used for the removal of submicron size particulates from air streams. In nuclear industry they are used as an important engineering safeguard to prevent the release of air borne radioactive particulates to the environment. HEPA filters used in the nuclear industry should therefore be manufactured and operated under strict quality control. There are three levels of testing HEPA filters: i) testing of the filter media; ii) testing of the assembled filter including filter media and filter housing; and iii) on site testing of the complete filter installation before putting into operation and later for the purpose of periodic control. A co-ordinated research programme on particulate filter testing methods was taken up by the Agency and contracts were awarded to the Member Countries, Belgium, German Democratic Republic, India and Hungary. The investigations carried out by the participants of the present co-ordinated research programme include the results of the nowadays most frequently used HEPA filter testing methods both for filter medium test, rig test and in-situ test purposes. Most of the experiments were carried out at ambient temperature and humidity, but indications were given to extend the investigations to elevated temperature and humidity in the future for the purpose of testing the performance of HEPA filter under severe conditions. A major conclusion of the co-ordinated research programme was that it was not possible to recommend one method as a reference method for in situ testing of high efficiency particulate air filters. Most of the present conventional methods are adequate for current requirements. The reasons why no method is to be recommended were multiple, ranging from economical aspects, through incompatibility of materials to national regulations

  15. Impact of a flattening filter free linear accelerator on structural shielding design

    International Nuclear Information System (INIS)

    Jank, Julia; Kragl, Gabriele; Georg, Dietmar; Medical University of Vienna

    2014-01-01

    Purpose: The present study aimed to assess the effects of a flattening filter free medical accelerator on structural shielding demands of a treatment vault of a medical linear accelerator. We tried to answer the question, to what extent the required thickness of the shielding barriers can be reduced if instead of the standard flattened photon beams unflattened ones are used. Material and Methods: We chose both an experimental as well as a theoretical approach. On the one hand we measured photon dose rates at protected places outside the treatment room and compared the obtained results for flattened and unflattened beams. On the other hand we complied with international guidelines for adequate treatment vault design and calculated the shielding barriers according to the therein given specifications. Measurements were performed with an Elekta Precise trademark linac providing nominal photon energies of 6 and 10 MV. This machine underwent already earlier some modifications in order to be able to operate both with and without a flattening filter. Photon dose rates were measured with a LB133-1 dose rate meter manufactured by Berthold. To calculate the thickness of shielding barriers we referred to the Austrian standard OeNORM S 5216 and to the US American NCRP Report No. 151. Results: We determined a substantial photon dose rate reduction for all measurement points and photon energies. For unflattened 6 MV beams a reduction factor ranging from 1.4 to 1.8 was identified. The corresponding values for unflattened 10 MV beams were 2.1 and 3.2. The performed shielding calculations indicated the same tendency: For all relevant radiation components we found a reduction in shielding thickness when unflattened beams were used. The required thickness of primary barriers was reduced up to 8.0%, the thickness of secondary barriers up to 11.4%, respectively. Conclusions: For an adequate dimensioning of treatment vault shielding barriers it is by no means irrelevant if the

  16. Impact of a flattening filter free linear accelerator on structural shielding design.

    Science.gov (United States)

    Jank, Julia; Kragl, Gabriele; Georg, Dietmar

    2014-03-01

    The present study aimed to assess the effects of a flattening filter free medical accelerator on structural shielding demands of a treatment vault of a medical linear accelerator. We tried to answer the question, to what extent the required thickness of the shielding barriers can be reduced if instead of the standard flattened photon beams unflattened ones are used. We chose both an experimental as well as a theoretical approach. On the one hand we measured photon dose rates at protected places outside the treatment room and compared the obtained results for flattened and unflattened beams. On the other hand we complied with international guidelines for adequate treatment vault design and calculated the shielding barriers according to the therein given specifications. Measurements were performed with an Elekta Precise™ linac providing nominal photon energies of 6 and 10 MV. This machine underwent already earlier some modifications in order to be able to operate both with and without a flattening filter. Photon dose rates were measured with a LB133-1 dose rate meter manufactured by Berthold. To calculate the thickness of shielding barriers we referred to the Austrian standard ÖNORM S 5216 and to the US American NCRP Report No. 151. We determined a substantial photon dose rate reduction for all measurement points and photon energies. For unflattened 6 MV beams a reduction factor ranging from 1.4 to 1.8 was identified. The corresponding values for unflattened 10 MV beams were 2.1 and 3.2. The performed shielding calculations indicated the same tendency: For all relevant radiation components we found a reduction in shielding thickness when unflattened beams were used. The required thickness of primary barriers was reduced up to 8.0%, the thickness of secondary barriers up to 11.4%, respectively. For an adequate dimensioning of treatment vault shielding barriers it is by no means irrelevant if the accommodated linac operates with or without a flattening filter. The

  17. Impact of a flattening filter free linear accelerator on structural shielding design

    Energy Technology Data Exchange (ETDEWEB)

    Jank, Julia [Klinikum - Klagenfurt am Woerthersee (Austria). Inst. fuer Strahlentherapie und Radioonkologie; Kragl, Gabriele [Medical University of Vienna/AKH Vienna (Austria). Div. Medical Radiation Physics; Georg, Dietmar [Medical University of Vienna/AKH Vienna (Austria). Div. Medical Radiation Physics; Medical University of Vienna (Austria). Christian Doppler Lab. for Medical Radiation Research for Radiation Oncology

    2014-04-01

    Purpose: The present study aimed to assess the effects of a flattening filter free medical accelerator on structural shielding demands of a treatment vault of a medical linear accelerator. We tried to answer the question, to what extent the required thickness of the shielding barriers can be reduced if instead of the standard flattened photon beams unflattened ones are used. Material and Methods: We chose both an experimental as well as a theoretical approach. On the one hand we measured photon dose rates at protected places outside the treatment room and compared the obtained results for flattened and unflattened beams. On the other hand we complied with international guidelines for adequate treatment vault design and calculated the shielding barriers according to the therein given specifications. Measurements were performed with an Elekta Precise trademark linac providing nominal photon energies of 6 and 10 MV. This machine underwent already earlier some modifications in order to be able to operate both with and without a flattening filter. Photon dose rates were measured with a LB133-1 dose rate meter manufactured by Berthold. To calculate the thickness of shielding barriers we referred to the Austrian standard OeNORM S 5216 and to the US American NCRP Report No. 151. Results: We determined a substantial photon dose rate reduction for all measurement points and photon energies. For unflattened 6 MV beams a reduction factor ranging from 1.4 to 1.8 was identified. The corresponding values for unflattened 10 MV beams were 2.1 and 3.2. The performed shielding calculations indicated the same tendency: For all relevant radiation components we found a reduction in shielding thickness when unflattened beams were used. The required thickness of primary barriers was reduced up to 8.0%, the thickness of secondary barriers up to 11.4%, respectively. Conclusions: For an adequate dimensioning of treatment vault shielding barriers it is by no means irrelevant if the

  18. Digital Simulation of a Hybrid Active Filter - An Active Filter in Series with a Shunt Passive Filter

    OpenAIRE

    Sitaram, Mahesh I; Padiyar, KR; Ramanarayanan, V

    1998-01-01

    Active filters have long been in use for the filtering of power system load harmonics. In this paper, the digital simulation results of a hybrid active power filter system for a rectifier load are presented. The active filter is used for filtering higher order harmonics as the dominant harmonics are filtered by the passive filter. This reduces the rating of the active filter significantly. The DC capacitor voltage of the active filter is controlled using a PI controller.

  19. Thermo-mechanical analysis of a user filter assembly for undulator/wiggler operations at the Advanced Photon Source

    International Nuclear Information System (INIS)

    Nian, H.L.T.; Kuzay, T.M.; Collins, J.; Shu, D.; Benson, C.; Dejus, R.

    1996-01-01

    This paper reports a thermo-mechanical study of a beamline filter (user filter) for undulator/wiggler operations. It is deployed in conjunction with the current commissioning window assembly on the APS insertion device (ID) front ends. The beamline filter at the Advanced Photon Source (APS) will eventually be used in windowless operations also. Hence survival and reasonable life expectancy of the filters under intense insertion device (ID) heat flu are crucial to the beamline operations. To accommodate various user requirements, the filter is configured to be a multi-choice type and smart to allow only those filter combinations that will be safe to operate with a given ring current and beamline insertion device gap. However, this paper addresses only the thermo-mechanical analysis of individual filter integrity and safety in all combinations possible. The current filter design is configured to have four filter frames in a cascade with each frame holding five filters. This allows a potential 625 total filter combinations. Thermal analysis for all of these combinations becomes a mammoth task considering the desired choices for filter materials (pyrolitic graphite and metallic filters), filter thicknesses, undulator gaps, and the beam currents. The paper addresses how this difficult task has been reduced to a reasonable effort and computational level. Results from thermo-mechanical analyses of the filter combinations are presented both in tabular and graphical format

  20. Supplementary High-Input Impedance Voltage-Mode Universal Biquadratic Filter Using DVCCs

    Directory of Open Access Journals (Sweden)

    Jitendra Mohan

    2012-01-01

    Full Text Available To further extend the existing knowledge on voltage-mode universal biquadratic filter, in this paper, a new biquadratic filter circuit with single input and multiple outputs is proposed, employing three differential voltage current conveyors (DVCCs, three resistors, and two grounded capacitors. The proposed circuit realizes all the standard filter functions, that is, high-pass, band-pass, low-pass, notch, and all-pass filters simultaneously. The circuit enjoys the feature of high-input impedance, orthogonal control of resonance angular frequency (o, and quality factor (Q via grounded resistor and the use of grounded capacitors which is ideal for IC implementation.

  1. XRF intermediate thickness layer technique for analysis of residue of hard to dissolve materials

    International Nuclear Information System (INIS)

    Mzyk, Z.; Mzyk, J.; Buzek, L.; Baranowska, I.

    1998-01-01

    This work presents a quick method for lead and silver determination in materials, such as slags from silver metallurgy and slimes from copper electrorefining, which are very difficult to dissolve, even using a microwave technique. The idea was to dissolve the possibly greatest amount of the sample using acids. Insoluble deposit was filtered out. Silver content in the solution was analysed by potentiometric titration or AAS, lead content by XRS, while sediment deposit on filter - by XRF intermediate thickness technique. The results of silver and lead analysis obtained by this method were compared with those obtained by classical method, i.e. melting the residue with sodium peroxide. (author)

  2. Semi-continuous casting of magnesium alloy AZ91 using a filtered melt delivery system

    Directory of Open Access Journals (Sweden)

    Mainul Hasan

    2015-12-01

    Full Text Available A 3-D numerical simulation of an industrial-sized slab caster for magnesium alloy AZ91 has been carried out for the steady state operational phase of the caster. The simulated model consists of an open-top melt delivery system fitted with a porous filter near the hot-top. The melt flow through the porous filter was modeled on the basis of Brinkmann-Forchimier-Extended non-Darcy model for turbulent flow. An in-house 3-D CFD code was modified to account for the melt flow through the porous filter. Results are obtained for four casting speeds namely, 40, 60, 80, and 100 mm/min. The metal-mold contact region as well as the convective heat transfer coefficient at the mold wall were also varied. In addition to the above, the Darcy number for the porous media was also changed. All parametric studies were performed for a fixed inlet melt superheat of 64 °C. The results are presented pictorially in the form of temperature and velocity fields. The sump depth, mushy region thickness, solid shell thickness at the exit of the mold and axial temperature profiles are also presented and correlated with the casting speed through regression analysis.

  3. Power Quality Improvement in a Cascaded Multilevel Inverter Interfaced Grid Connected System Using a Modified Inductive–Capacitive–Inductive Filter with Reduced Power Loss and Improved Harmonic Attenuation

    Directory of Open Access Journals (Sweden)

    Meenakshi Jayaraman

    2017-11-01

    Full Text Available Recently, multilevel inverters are more researched due to the advantages they offer over conventional voltage source inverters in grid connected applications. Passive filters are connected at the output of these inverters to produce sinusoidal waveforms with reduced harmonics and to satisfy grid interconnection standard requirements. This work proposes a new passive filter topology for a pulse width modulated five-level cascaded inverter interfaced grid connected system. The proposed passive filter inserts an additional resistance-capacitance branch in parallel to the filter capacitor of the traditional inductive–capacitive–inductive filter in addition to a resistance in series with it to reduce damping power loss. It can attenuate the switching frequency harmonic current components much better than the traditional filter while maintaining the same overall inductance, reduced capacitance and resistance values. The basic parameter design procedure and an approach to discover the parameters of the proposed filter is introduced. Further, a novel methodology using Particle Swarm Optimization (PSO is recommended to guarantee minimum damping loss while ensuring reduced peak during resonance. In addition, PSO algorithm is newly employed in this work to maximize harmonic attenuation in and around the switching frequency on the premise of allowable values of filter inductance and capacitance. A comparative discussion considering traditional passive filters and the proposed filter is presented and evaluated through experiments conducted on a 110 V, 1 kW five-level grid connected inverter. The modulation algorithm for the multilevel inverter is implemented using a SPARTAN 6-XC6SLX25 Field Programmable Gate Array (FPGA processor. The analysis shows that the proposed filter not only provides decreased damping power loss but also is capable of providing considerable harmonic ripple reduction in the high frequency band, improved output waveforms and lesser

  4. Review of Department of Energy HEPA filter test activities, FY 1990--FY 1992

    International Nuclear Information System (INIS)

    McIntyre, J.A.

    1992-01-01

    Filter Test Facilities (FTFs) and the FTF Technical Support Group (TSG) continue to provide services to the Department of Energy (DOE). Additional tasks relating to the HEPA filter cycle have been added to the TSG. The tasks include the quality assessment review for the in-place testing of HEPA filters at DOE sites and the formation of an in-place testing standards writing group. Summary of ongoing FTFs and TSG activities for FY 1990-FY 1992 including the technical input for implementation of the High Flow Alternative Test System (HFATS), update of the DOE Standards, the status of the quality assessment review and in-place testing standards writing group are discussed

  5. Dust collected in air filters - Possible source of volatile organic compounds and particles; Ger smutsiga luftfilter foersaemrad tilluft ? En studie av emissioner med ursprung i filter

    Energy Technology Data Exchange (ETDEWEB)

    Johansson, J.H.P.; Rosell, Lars

    1998-06-01

    material showed spores and fragments of hyphae upstream of the filter with less spores and no hyphae on the downstream side. The amount of colonization units was much higher on the upstream side as well. This indicates no growth on the filter material. This investigation indicates no obvious deterioration of the air quality due to the dust in air filters. With some reservation for smell and other parameters not measured, these moderately polluted air filters were not considered to be a hygienic problem, even though the filters were occasionally dampened. The problem of how dirtier filters may affect the air quality should, however, be investigated 37 refs, 28 figs, 25 tabs

  6. Optimal search filters for renal information in EMBASE.

    Science.gov (United States)

    Iansavichus, Arthur V; Haynes, R Brian; Shariff, Salimah Z; Weir, Matthew; Wilczynski, Nancy L; McKibbon, Ann; Rehman, Faisal; Garg, Amit X

    2010-07-01

    EMBASE is a popular database used to retrieve biomedical information. Our objective was to develop and test search filters to help clinicians and researchers efficiently retrieve articles with renal information in EMBASE. We used a diagnostic test assessment framework because filters operate similarly to screening tests. We divided a sample of 5,302 articles from 39 journals into development and validation sets of articles. Information retrieval properties were assessed by treating each search filter as a "diagnostic test" or screening procedure for the detection of relevant articles. We tested the performance of 1,936,799 search filters made of unique renal terms and their combinations. REFERENCE STANDARD & OUTCOME: The reference standard was manual review of each article. We calculated the sensitivity and specificity of each filter to identify articles with renal information. The best renal filters consisted of multiple search terms, such as "renal replacement therapy," "renal," "kidney disease," and "proteinuria," and the truncated terms "kidney," "dialy," "neph," "glomerul," and "hemodial." These filters achieved peak sensitivities of 98.7% (95% CI, 97.9-99.6) and specificities of 98.5% (95% CI, 98.0-99.0). The retrieval performance of these filters remained excellent in the validation set of independent articles. The retrieval performance of any search will vary depending on the quality of all search concepts used, not just renal terms. We empirically developed and validated high-performance renal search filters for EMBASE. These filters can be programmed into the search engine or used on their own to improve the efficiency of searching.

  7. Computation of nuclear reactor parameters using a stretch Kalman filtering

    International Nuclear Information System (INIS)

    Zwingelstein, G.; Poujol, A.

    1976-01-01

    A method of nonlinear stochastic filtering, the stretched Karman filter, is used for the estimation of two basic parameters involved in the control of nuclear reactor start-up. The corresponding algorithm is stored in a small Multi-8 computer and tested with data recorded for the Ulysse reactor (I.N.S.T.N.). The various practical problems involved in using the algorithm are examined: filtering initialization, influence of the model... The quality and time saving obtained in the computation make it possible for a real time operation, the computer being connected with the reactor [fr

  8. Resveratrol increases nitric oxide production in the rat thick ascending limb via Ca2+/calmodulin.

    Science.gov (United States)

    Gonzalez-Vicente, Agustin; Cabral, Pablo D; Garvin, Jeffrey L

    2014-01-01

    The thick ascending limb of the loop of Henle reabsorbs 30% of the NaCl filtered through the glomerulus. Nitric oxide (NO) produced by NO synthase 3 (NOS3) inhibits NaCl absorption by this segment. Resveratrol, a polyphenol, has beneficial cardiovascular and renal effects, many of which are mediated by NO. Resveratrol increases intracellular Ca2+ (Cai) and AMP kinase (AMPK) and NAD-dependent deacetylase sirtuin1 (SIRT1) activities, all of which could activate NO production. We hypothesized that resveratrol stimulates NO production by thick ascending limbs via a Ca2+/calmodulin-dependent mechanism. To test this, the effect of resveratrol on NO bioavailability was measured in thick ascending limb suspensions. Cai was measured in single perfused thick ascending limbs. SIRT1 activity and expression were measured in thick ascending limb lysates. Resveratrol (100 µM) increased NO bioavailability in thick ascending limb suspensions by 1.3±0.2 AFU/mg/min (pthick ascending limbs via a Ca2+/calmodulin dependent mechanism, and SIRT1 and AMPK do not participate. Resveratrol-stimulated NO production in thick ascending limbs may account for part of its beneficial effects.

  9. Evaluation of anterior urethral stricture using thick slab SSFSE MR urethrography

    Energy Technology Data Exchange (ETDEWEB)

    Park, Byung Kwan; Kim, Chan Kyo (Dept. of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan Univ. School of Medicine, Seoul (Korea)), e-mail: rapark@skku.edu; Lee, Sung Won (Dept. of Urology, Samsung Medical Center, Sungkyunkwan Univ. School of Medicine, Seoul (Korea))

    2010-12-15

    Background: Magnetic resonance urethrography (MRU) can be used for depicting not only anterior urethral strictures but also periurethral anatomy in order to produce a management plan. Purpose: To determine if thick slab single-shot fast spin echo (SSFSE) MRU is useful for evaluating anterior urethral stricture compared to fast recovery fast spin echo (FRFSE) MRU. Material and Methods: Ten patients with benign anterior urethral stricture underwent both thick slab SSFSE MRU and FRFSE MRU using sterile jelly for urethral distension before retrograde urethrography. The glans penis was tied at the time of MRU. The two types of MR image were compared regarding stricture length, scan time, and image quality. We also determined whether or not both of the two MR sequences could display an entire anterior urethra on one image. Results: The stricture length on thick slab SSFSE and FRFSE MRU ranged from 4.0 to 71.3 mm (36.4 {+-} 21.8 mm) and from 4.0 to 67.5 mm (35.7 {+-} 20.8 mm), respectively (P > 0.05). The mean scan time for thick slab SSFSE and FRFSE sequences was 2 s and 194 s, respectively (P < 0.05). However, regarding image quality, thick slab SSFSE MRU was inferior to FRFSE MRU (P < 0.05). All the thick slab SSFSE MRU displayed the entire anterior urethra on one image, while only five FRFSE MRU did so (P < 0.05). Conclusion: Thick slab SSFSE MRU can provide a concordant stricture length when compared to the FRFSE MRU and imaging of the entire length of the anterior urethral stricture with subjective reduced image quality and scan time.

  10. Evaluation of anterior urethral stricture using thick slab SSFSE MR urethrography

    International Nuclear Information System (INIS)

    Park, Byung Kwan; Kim, Chan Kyo; Lee, Sung Won

    2010-01-01

    Background: Magnetic resonance urethrography (MRU) can be used for depicting not only anterior urethral strictures but also periurethral anatomy in order to produce a management plan. Purpose: To determine if thick slab single-shot fast spin echo (SSFSE) MRU is useful for evaluating anterior urethral stricture compared to fast recovery fast spin echo (FRFSE) MRU. Material and Methods: Ten patients with benign anterior urethral stricture underwent both thick slab SSFSE MRU and FRFSE MRU using sterile jelly for urethral distension before retrograde urethrography. The glans penis was tied at the time of MRU. The two types of MR image were compared regarding stricture length, scan time, and image quality. We also determined whether or not both of the two MR sequences could display an entire anterior urethra on one image. Results: The stricture length on thick slab SSFSE and FRFSE MRU ranged from 4.0 to 71.3 mm (36.4 21.8 mm) and from 4.0 to 67.5 mm (35.7 20.8 mm), respectively (P > 0.05). The mean scan time for thick slab SSFSE and FRFSE sequences was 2 s and 194 s, respectively (P < 0.05). However, regarding image quality, thick slab SSFSE MRU was inferior to FRFSE MRU (P < 0.05). All the thick slab SSFSE MRU displayed the entire anterior urethra on one image, while only five FRFSE MRU did so (P < 0.05). Conclusion: Thick slab SSFSE MRU can provide a concordant stricture length when compared to the FRFSE MRU and imaging of the entire length of the anterior urethral stricture with subjective reduced image quality and scan time.

  11. Time-Sequential Working Wavelength-Selective Filter for Flat Autostereoscopic Displays

    Directory of Open Access Journals (Sweden)

    René de la Barré

    2017-02-01

    Full Text Available A time-sequential working, spatially-multiplexed autostereoscopic 3D display design consisting of a fast switchable RGB-color filter array and a fast color display is presented. The newly-introduced 3D display design is usable as a multi-user display, as well as a single-user system. The wavelength-selective filter barrier emits the light from a larger aperture than common autostereoscopic barrier displays with similar barrier pitch and ascent. Measurements on a demonstrator with commercial display components, simulations and computational evaluations have been carried out to describe the proposed wavelength-selective display design in static states and to show the weak spots of display filters in commercial displays. An optical modelling of wavelength-selective barriers has been used for instance to calculate the light ray distribution properties of that arrangement. In the time-sequential implementation, it is important to avoid that quick eye or eyelid movement leads to visible color artifacts. Therefore, color filter cells, switching faster than conventional LC display cells, must distribute directed light from different primaries at the same time, to create a 3D presentation. For that, electric tunable liquid crystal Fabry–Pérot color filters are presented. They switch on-off the colors red, green and blue in the millisecond regime. Their active areas consist of a sub-micrometer-thick nematic layer sandwiched between dielectric mirrors and indium tin oxide (ITO-electrodes. These cells shall switch narrowband light of red, green or blue. A barrier filter array for a high resolution, glasses-free 3D display has to be equipped with several thousand switchable filter elements having different color apertures.

  12. DSP based adaptive hysteresis-band current controlled active filter ...

    African Journals Online (AJOL)

    The use of non-linear loads critically affects the quality of supply by drawing harmonic currents and reactive power from the electrical distribution system. Active power filters are the most viable solution for solving such power quality problems in compliance with the harmonic standards. This article presents a digital signal ...

  13. Critical thickness of high structural quality SrTiO{sub 3} films grown on orthorhombic (101) DyScO{sub 3}.

    Energy Technology Data Exchange (ETDEWEB)

    Biegalski, M. D.; Trolier-McKinstry, S.; Nelson, C. T.; Schlom, D. G.; Fong, D. D.; Eastman, J. A.; Fuoss, P. H.; Streiffer, S. K.; Heeg, T.; Schubert, J.; Tian, W.; Pan, X. Q.; Hawley, M. E.; Bernhagen, M.; Reiche, P.; Uecker, R.; Pennsylvania State Univ.; Forschungszentrum Julich; Univ. Michigan; LANL; Max-Born-Strabe

    2008-12-01

    Strained epitaxial SrTiO{sub 3} films were grown on orthorhombic (101) DyScO{sub 3} substrates by reactive molecular-beam epitaxy. The epitaxy of this substrate/film combination is cube on cube with a pseudocubic out-of-plane (001) orientation. The strain state and structural perfection of films with thicknesses ranging from 50 to 1000 {angstrom} were examined using x-ray scattering. The critical thickness at which misfit dislocations was introduced was between 350 and 500 {angstrom}. These films have the narrowest rocking curves (full width at half maximum) ever reported for any heteroepitaxial oxide film (0.0018{sup o}). Only a modest amount of relaxation is seen in films exceeding the critical thicknesses even after postdeposition annealing at 700 C in 1 atm of oxygen. The dependence of strain relaxation on crystallographic direction is attributed to the anisotropy of the substrate. These SrTiO{sub 3} films show structural quality more typical of semiconductors such as GaAs and silicon than perovskite materials; their structural relaxation behavior also shows similarity to that of compound semiconductor films.

  14. Frame Filtering and Skipping for Point Cloud Data Video Transmission

    Directory of Open Access Journals (Sweden)

    Carlos Moreno

    2017-01-01

    Full Text Available Sensors for collecting 3D spatial data from the real world are becoming more important. They are a prime research area topic and have applications in consumer markets, such as medical, entertainment, and robotics. However, a primary concern with collecting this data is the vast amount of information being generated, and thus, needing to be processed before being transmitted. To address the issue, we propose the use of filtering methods and frame skipping. To collect the 3D spatial data, called point clouds, we used the Microsoft Kinect sensor. In addition, we utilized the Point Cloud Library to process and filter the data being generated by the Kinect. Two different computers were used: a client which collects, filters, and transmits the point clouds; and a server that receives and visualizes the point clouds. The client is also checking for similarity in consecutive frames, skipping those that reach a similarity threshold. In order to compare the filtering methods and test the effectiveness of the frame skipping technique, quality of service (QoS metrics such as frame rate and percentage of filter were introduced. These metrics indicate how well a certain combination of filtering method and frame skipping accomplishes the goal of transmitting point clouds from one location to another. We found that the pass through filter in conjunction with frame skipping provides the best relative QoS. However, results also show that there is still too much data for a satisfactory QoS. For a real-time system to provide reasonable end-to-end quality, dynamic compression and progressive transmission need to be utilized.

  15. Growth of High-Quality GaAs on Ge by Controlling the Thickness and Growth Temperature of Buffer Layer

    Science.gov (United States)

    Zhou, Xu-Liang; Pan, Jiao-Qing; Yu, Hong-Yan; Li, Shi-Yan; Wang, Bao-Jun; Bian, Jing; Wang, Wei

    2014-12-01

    High-quality GaAs thin films grown on miscut Ge substrates are crucial for GaAs-based devices on silicon. We investigate the effect of different thicknesses and temperatures of GaAs buffer layers on the crystal quality and surface morphology of GaAs on Ge by metal-organic chemical vapor deposition. Through high resolution x-ray diffraction measurements, it is demonstrated that the full width at half maximum for the GaAs epilayer (Ge substrate) peak could achieve 19.3 (11.0) arcsec. The value of etch pit density could be 4×104 cm-2. At the same time, GaAs surfaces with no pyramid-shaped pits are obtained when the buffer layer growth temperature is lower than 360°C, due to effective inhibition of initial nucleation at terraces of the Ge surface. In addition, it is shown that large island formation at the initial stage of epitaxial growth is a significant factor for the final rough surface and that this initial stage should be carefully controlled when a device quality GaAs surface is desired.

  16. Restoration of Static JPEG Images and RGB Video Frames by Means of Nonlinear Filtering in Conditions of Gaussian and Non-Gaussian Noise

    Science.gov (United States)

    Sokolov, R. I.; Abdullin, R. R.

    2017-11-01

    The use of nonlinear Markov process filtering makes it possible to restore both video stream frames and static photos at the stage of preprocessing. The present paper reflects the results of research in comparison of these types image filtering quality by means of special algorithm when Gaussian or non-Gaussian noises acting. Examples of filter operation at different values of signal-to-noise ratio are presented. A comparative analysis has been performed, and the best filtered kind of noise has been defined. It has been shown the quality of developed algorithm is much better than quality of adaptive one for RGB signal filtering at the same a priori information about the signal. Also, an advantage over median filter takes a place when both fluctuation and pulse noise filtering.

  17. Structural shielding design of a 6 MV flattening filter free linear accelerator: Indian scenario

    Directory of Open Access Journals (Sweden)

    Bibekananda Mishra

    2017-01-01

    Full Text Available Detailed structural shielding of primary and secondary barriers for a 6 MV medical linear accelerator (LINAC operated with flattening filter (FF and flattening filter free (FFF modes are calculated. The calculations have been carried out by two methods, one using the approach given in National Council on Radiation Protection (NCRP Report No. 151 and the other based on the monitor units (MUs delivered in clinical practice. Radiation survey of the installations was also carried out. NCRP approach suggests that the primary and secondary barrier thicknesses are higher by 24% and 26%. respectively, for a LINAC operated in FF mode to that of a LINAC operated in both FF and FFF modes with an assumption that only 20% of the workload is shared in FFF mode. Primary and secondary barrier thicknesses calculated from MUs delivered on clinical practice method also show the same trend and are higher by 20% and 19%, respectively, for a LINAC operated in FF mode to that of a LINAC operated in both FF and FFF modes. Overall, the barrier thickness for a LINAC operated in FF mode is higher about 20% to that of a LINAC operated in both FF and FFF modes.

  18. Filter assembly for metallic and intermetallic tube filters

    Science.gov (United States)

    Alvin, Mary Anne; Lippert, Thomas E.; Bruck, Gerald J.; Smeltzer, Eugene E.

    2001-01-01

    A filter assembly (60) for holding a filter element (28) within a hot gas cleanup system pressure vessel is provided, containing: a filter housing (62), said filter housing having a certain axial length and having a peripheral sidewall, said sidewall defining an interior chamber (66); a one piece, all metal, fail-safe/regenerator device (68) within the interior chamber (66) of the filter housing (62) and/or extending beyond the axial length of the filter housing, said device containing an outward extending radial flange (71) within the filter housing for seating an essential seal (70), the device also having heat transfer media (72) disposed inside and screens (80) for particulate removal; one compliant gasket (70) positioned next to and above the outward extending radial flange of the fail-safe/regenerator device; and a porous metallic corrosion resistant superalloy type filter element body welded at the bottom of the metal fail-safe/regenerator device.

  19. Phosphorus retention by fly-ash amended filter media in aged bioretention cells

    Science.gov (United States)

    Bioretention cells (BRCs) have shown potential for stormwater quantity and quality control. However, the phosphorus (P) removal in BRC has been variable due to differences of soil properties in filter media. The objectives of this research were to identify and evaluate P accumulation in filter media...

  20. Statistically-Efficient Filtering in Impulsive Environments: Weighted Myriad Filters

    Directory of Open Access Journals (Sweden)

    Juan G. Gonzalez

    2002-01-01

    Full Text Available Linear filtering theory has been largely motivated by the characteristics of Gaussian signals. In the same manner, the proposed Myriad Filtering methods are motivated by the need for a flexible filter class with high statistical efficiency in non-Gaussian impulsive environments that can appear in practice. Myriad filters have a solid theoretical basis, are inherently more powerful than median filters, and are very general, subsuming traditional linear FIR filters. The foundation of the proposed filtering algorithms lies in the definition of the myriad as a tunable estimator of location derived from the theory of robust statistics. We prove several fundamental properties of this estimator and show its optimality in practical impulsive models such as the α-stable and generalized-t. We then extend the myriad estimation framework to allow the use of weights. In the same way as linear FIR filters become a powerful generalization of the mean filter, filters based on running myriads reach all of their potential when a weighting scheme is utilized. We derive the “normal” equations for the optimal myriad filter, and introduce a suboptimal methodology for filter tuning and design. The strong potential of myriad filtering and estimation in impulsive environments is illustrated with several examples.

  1. Preparation and investigation of diamond-like carbon stripper foils by filtered cathodic vacuum arc

    International Nuclear Information System (INIS)

    Fan, Qiwen; Du, Yinghui; Zhang, Rong; Xu, Guoji

    2013-01-01

    Thin diamond-like carbon (DLC) stripper foils ∼5μg/cm 2 in thickness were produced and evaluated as heavy-ion strippers for the Beijing HI-13 Tandem Accelerator. The DLC layers ∼4μg/cm 2 in thickness were produced by the filtered cathodic vacuum arc technology onto glass slides coated with betaine–saccharose as releasing agent, which were previously covered with evaporated carbon layers ∼1μg/cm 2 in thickness by the controlled ac arc-discharge method. Irradiation lifetimes of the DLC stripper foils were tested using the heavy-ion beams at the terminal of the Beijing HI-13 Tandem Accelerator, and compared with those of the standard carbon stripper foils made by the combined dc and ac arc-discharge method. The measurements indicate that the DLC stripper foils outlast the standard combined dc and ac arc-discharge carbon stripper foils by a factor of at least 13 and 4 for the 197 Au − (∼9MeV, ∼1μA) and 63 Cu − (∼9MeV, ∼1μA) ion beams, respectively. The structure and properties of the DLC foils deposited onto silicon substrates by the filtered cathodic vacuum arc technology were also evaluated and analyzed by scanning electron microscopy, Raman spectroscopy and X-ray photoelectron spectroscopy. The scanning electron microscopy images show that the DLC foils contain hardly droplets through the double 90° filters. The X-ray photoelectron spectrum indicates that sp 3 bonds of the DLC foils exceed 70%. The integral intensity ratio of the D peak to the G peak (I D /I G ) measured by the Raman spectroscopy is 0.78

  2. Evaluating Assessment Using N-Dimensional Filtering.

    Science.gov (United States)

    Dron, Jon; Boyne, Chris; Mitchell, Richard

    This paper describes the use of the CoFIND (Collaborative Filter in N Dimensions) system to evaluate two assessment styles. CoFIND is a resource database that organizes itself around its users' needs. Learners enter resources, categorize, then rate them using "qualities," aspects of resources which learners find worthwhile, the n…

  3. Filter material charging apparatus for filter assembly for radioactive contaminants

    International Nuclear Information System (INIS)

    Goldsmith, J.M.; O'Nan, A. Jr.

    1977-01-01

    A filter charging apparatus for a filter assembly is described. The filter assembly includes a housing with at least one filter bed therein and the filter charging apparatus for adding filter material to the filter assembly includes a tank with an opening therein, the tank opening being disposed in flow communication with opposed first and second conduit means, the first conduit means being in flow communication with the filter assembly housing and the second conduit means being in flow communication with a blower means. Upon activation of the blower means, the blower means pneumatically conveys the filter material from the tank to the filter housing

  4. Beta-spectrometer with magnetic filter of mini orange type

    International Nuclear Information System (INIS)

    Gorozhankin, V.M.; Gromov, K.Ya.; Kalinnikov, V.G.; Sereeter, Z.; Fominykh, V.I.; Malikov, Sh.R.; Yuldashev, M.B.

    1997-01-01

    At the ISOL facility YASNAPP-2 a β-spectrometer with a magnetic filter of the miniorange type is constructed to measure γ-ray internal conversion coefficients. The magnetic filter of the mini orange type is an assemblage of permanent magnets creating a toroidal magnetic field perpendicular to the electron trajectories from the source to the Si(Li) detector. The chosen profile of the permanent magnets allowed electron registration in the defined energy energy interval with some transmission increase. There are two sets of permanent magnets of the different thickness. Varying the type and number of permanent magnets one can set the detected electron energy intervals in a 50-2500 keV range. The efficiency of the spectrometer was investigated for different assemblages of the mini orange magnet. The facility can be used for the e-γ coincidence investigation. (A.A.D.)

  5. Determination of optimum filter in myocardial SPECT: A phantom study

    International Nuclear Information System (INIS)

    Takavar, A.; Shamsipour, Gh.; Sohrabi, M.; Eftekhari, M.

    2004-01-01

    Background: In myocardial perfusion SPECT images are degraded by photon attenuation, the distance-dependent collimator, detector response and photons scatter. Filters greatly affect quality of nuclear medicine images. Materials and Methods: A phantom simulating heart left ventricle was built. About 1mCi of 99m Tc was injected into the phantom. Images was taken from this phantom. Some filters including Parzen, Hamming, Hanning, Butter worth and Gaussian were exerted on the phantom images. By defining some criteria such as contrast, signal to noise ratio, and defect size detectability, the best filter can be determined. Results: 0.325 Nyquist frequency and 0.5 nq was obtained as the optimum cut off frequencies respectively for hamming and handing filters. Order 11, cut off 0.45 Nq and order 20 cut off 0.5 Nq obtained optimum respectively for Butter worth and Gaussian filters. Conclusion: The optimum member of every filter's family was obtained

  6. Convex blind image deconvolution with inverse filtering

    Science.gov (United States)

    Lv, Xiao-Guang; Li, Fang; Zeng, Tieyong

    2018-03-01

    Blind image deconvolution is the process of estimating both the original image and the blur kernel from the degraded image with only partial or no information about degradation and the imaging system. It is a bilinear ill-posed inverse problem corresponding to the direct problem of convolution. Regularization methods are used to handle the ill-posedness of blind deconvolution and get meaningful solutions. In this paper, we investigate a convex regularized inverse filtering method for blind deconvolution of images. We assume that the support region of the blur object is known, as has been done in a few existing works. By studying the inverse filters of signal and image restoration problems, we observe the oscillation structure of the inverse filters. Inspired by the oscillation structure of the inverse filters, we propose to use the star norm to regularize the inverse filter. Meanwhile, we use the total variation to regularize the resulting image obtained by convolving the inverse filter with the degraded image. The proposed minimization model is shown to be convex. We employ the first-order primal-dual method for the solution of the proposed minimization model. Numerical examples for blind image restoration are given to show that the proposed method outperforms some existing methods in terms of peak signal-to-noise ratio (PSNR), structural similarity (SSIM), visual quality and time consumption.

  7. Continuous thickness control of extruded pipes with assistance of microcomputers

    International Nuclear Information System (INIS)

    Breil, J.

    1983-06-01

    Because of economic and quality securing reasons a constant wall thickness of extruded pipes in circumference and extrusion direction is an important production aim. Therefore a microcomputer controlled system was developed, which controls die centering with electric motors. The control of wall thickness distribution; was realized with two conceptions: a dead time subjected control with a rotating on line wall thickness measuring instrument and an adaptive control with sensors in the pipe die. With a PI-algorithm excentricities of 30% of the wall thickness could be controlled below a trigger level of 2% within three dead times. (orig.) [de

  8. Dual mode operation, highly selective nanohole array-based plasmonic colour filters

    Science.gov (United States)

    Fouladi Mahani, Fatemeh; Mokhtari, Arash; Mehran, Mahdiyeh

    2017-09-01

    Taking advantage of nanostructured metal films as plasmonic colour filters (PCFs) has been evolved remarkably as an alternative to the conventional technologies of chemical colour filtering. However, most of the proposed PCFs depict a poor colour purity focusing on generating either the additive or subtractive colours. In this paper, we present dual mode operation PCFs employing an opaque aluminium film patterned with sub-wavelength holes. Subtractive colours like cyan, magenta, and yellow are the results of reflection mode of these filters yielding optical efficiencies as high as 70%-80% and full width at half maximum of the stop-bands up to 40-50 nm. The colour selectivity of the transmission mode for the additive colours is also significant due to their enhanced performance through the utilization of a relatively thick aluminium film in contact with a modified dielectric environment. These filters provide a simple design with one-step lithography in addition to compatibility with the conventional CMOS processes. Moreover, they are polarization insensitive due to their symmetric geometry. A complete palette of pure subtractive and additive colours has been realized with potential applications, such as multispectral imaging, CMOS image sensors, displays, and colour printing.

  9. Nanoscale Energy-Filtered Scanning Confocal Electron Microscopy Using a Double-Aberration-Corrected Transmission Electron Microscope

    International Nuclear Information System (INIS)

    Wang Peng; Behan, Gavin; Kirkland, Angus I.; Nellist, Peter D.; Takeguchi, Masaki; Hashimoto, Ayako; Mitsuishi, Kazutaka; Shimojo, Masayuki

    2010-01-01

    We demonstrate that a transmission electron microscope fitted with two spherical-aberration correctors can be operated as an energy-filtered scanning confocal electron microscope. A method for establishing this mode is described and initial results showing 3D chemical mapping with nanoscale sensitivity to height and thickness changes in a carbon film are presented. Importantly, uncorrected chromatic aberration does not limit the depth resolution of this technique and moreover performs an energy-filtering role, which is explained in terms of a combined depth and energy-loss response function.

  10. Correction for the absorption of plutonium alpha particles in filter paper used for dust sampling

    Energy Technology Data Exchange (ETDEWEB)

    Simons, J G

    1956-01-01

    This sample of air-borne dust collected on a filter paper when laboratory air is monitored for plutonium with the 1195 portable dust sampling unit may be regarded, for counting purposes, as a thick source with a non-uniform distribution of alpha-active plutonium. Experiments have been carried out to determine a correction factor to be applied to the observed count on the filter paper sample to correct for internal absorption in the paper and on the dust layer. From the results obtained it is recommended that a correction factor of 2 be used.

  11. Locally-adaptive Myriad Filters for Processing ECG Signals in Real Time

    Directory of Open Access Journals (Sweden)

    Nataliya Tulyakova

    2017-03-01

    Full Text Available The locally adaptive myriad filters to suppress noise in electrocardiographic (ECG signals in almost in real time are proposed. Statistical estimates of efficiency according to integral values of such criteria as mean square error (MSE and signal-to-noise ratio (SNR for the test ECG signals sampled at 400 Hz embedded in additive Gaussian noise with different values of variance are obtained. Comparative analysis of adaptive filters is carried out. High efficiency of ECG filtering and high quality of signal preservation are demonstrated. It is shown that locally adaptive myriad filters provide higher degree of suppressing additive Gaussian noise with possibility of real time implementation.

  12. Design of Passive Power Filter for Hybrid Series Active Power Filter using Estimation, Detection and Classification Method

    Science.gov (United States)

    Swain, Sushree Diptimayee; Ray, Pravat Kumar; Mohanty, K. B.

    2016-06-01

    This research paper discover the design of a shunt Passive Power Filter (PPF) in Hybrid Series Active Power Filter (HSAPF) that employs a novel analytic methodology which is superior than FFT analysis. This novel approach consists of the estimation, detection and classification of the signals. The proposed method is applied to estimate, detect and classify the power quality (PQ) disturbance such as harmonics. This proposed work deals with three methods: the harmonic detection through wavelet transform method, the harmonic estimation by Kalman Filter algorithm and harmonic classification by decision tree method. From different type of mother wavelets in wavelet transform method, the db8 is selected as suitable mother wavelet because of its potency on transient response and crouched oscillation at frequency domain. In harmonic compensation process, the detected harmonic is compensated through Hybrid Series Active Power Filter (HSAPF) based on Instantaneous Reactive Power Theory (IRPT). The efficacy of the proposed method is verified in MATLAB/SIMULINK domain and as well as with an experimental set up. The obtained results confirm the superiority of the proposed methodology than FFT analysis. This newly proposed PPF is used to make the conventional HSAPF more robust and stable.

  13. Aqueous-based thick photoresist removal for bumping applications

    Science.gov (United States)

    Moore, John C.; Brewer, Alex J.; Law, Alman; Pettit, Jared M.

    2015-03-01

    Cleaning processes account for over 25% of processing in microelectronic manufacturing [1], suggesting electronics to be one of the most chemical intensive markets in commerce. Industry roadmaps exist to reduce chemical exposure, usage, and waste [2]. Companies are encouraged to create a safer working environment, or green factory, and ultimately become certified similar to LEED in the building industry [3]. A significant step in this direction is the integration of aqueous-based photoresist (PR) strippers which eliminate regulatory risks and cut costs by over 50%. One of the largest organic solvent usages is based upon thick PR removal during bumping processes [4-6]. Using market projections and the benefits of recycling, it is estimated that over 1,000 metric tons (mt) of residuals originating from bumping processes are incinerated or sent to a landfill. Aqueous-based stripping would eliminate this disposal while also reducing the daily risks to workers and added permitting costs. Positive-tone PR dissolves in aqueous strippers while negative-tone systems are lifted-off from the substrate, bumps, pillars, and redistribution layers (RDL). While the wafers are further processed and rinsed, the lifted-off PR is pumped from the tank, collected onto a filter, and periodically back-flushed to the trash. The PR solids become a non-hazardous plastic waste while the liquids are mixed with the developer stream, neutralized, filtered, and in most cases, disposed to the sewer. Regardless of PR thickness, removal processes may be tuned to perform in <15min, performing at rates nearly 10X faster than solvents with higher bath lives. A balanced formula is safe for metals, dielectrics, and may be customized to any fab.

  14. Power Quality Improvement and LVRT Capability Enhancement of Wind Farms by Means of an Inductive Filtering Method

    Directory of Open Access Journals (Sweden)

    Yanjian Peng

    2016-04-01

    Full Text Available Unlike the traditional method for power quality improvement and low-voltage ride through (LVRT capability enhancement of wind farms, this paper proposes a new wind power integrated system by means of an inductive filtering method, especially if it contains a grid-connected transformer, a static synchronous compensator (STATCOM and fully-tuned (FT branches. First, the main circuit topology of the new wind power integrated system is presented. Then, the mathematical model is established to reveal the mechanism of harmonic suppression and the reactive compensation of the proposed wind power integrated system, and then the realization conditions of the inductive filtering method is obtained. Further, the control strategy of STATCOM is introduced. Based on the measured data for a real wind farm, the simulation studies are carried out to illustrate the performance of the proposed new wind power integrated system. The results indicate that the new system can not only enhance the LVRT capability of wind farms, but also prevent harmonic components flowing into the primary (grid winding of the grid-connected transformer. Moreover, since the new method can compensate for reactive power in a wind farm, the power factor at the grid side can be improved effectively.

  15. Robust heart rate estimation from multiple asynchronous noisy sources using signal quality indices and a Kalman filter

    International Nuclear Information System (INIS)

    Li, Q; Mark, R G; Clifford, G D

    2008-01-01

    Physiological signals such as the electrocardiogram (ECG) and arterial blood pressure (ABP) in the intensive care unit (ICU) are often severely corrupted by noise, artifact and missing data, which lead to large errors in the estimation of the heart rate (HR) and ABP. A robust HR estimation method is described that compensates for these problems. The method is based upon the concept of fusing multiple signal quality indices (SQIs) and HR estimates derived from multiple electrocardiogram (ECG) leads and an invasive ABP waveform recorded from ICU patients. Physiological SQIs were obtained by analyzing the statistical characteristics of each waveform and their relationships to each other. HR estimates from the ECG and ABP are tracked with separate Kalman filters, using a modified update sequence based upon the individual SQIs. Data fusion of each HR estimate was then performed by weighting each estimate by the Kalman filters' SQI-modified innovations. This method was evaluated on over 6000 h of simultaneously acquired ECG and ABP from a 437 patient subset of ICU data by adding real ECG and realistic artificial ABP noise. The method provides an accurate HR estimate even in the presence of high levels of persistent noise and artifact, and during episodes of extreme bradycardia and tachycardia

  16. Submerged Pond Sand Filter-A Novel Approach to Rural Water Supply

    DEFF Research Database (Denmark)

    Øhlenschlæger, Mia; Christensen, Sarah Christine Boesgaard; Bregnhøj, Henrik

    2016-01-01

    This study describes the new design and function of a modified version of a traditional slow sand filter. The Submerged Pond Sand Filter is built inside a pond and has a vertical as well as a horizontal flow of water through a sloped filter opening. The filter provides treated drinking water...... to a rural Indian village. The filter has functioned with minimal maintenance for five years without being subject to the typical scraping off and changing of sand as needed in traditional slow sand filters every few months. This five-year study showed bacterial removal efficiency of 97% on average...... to 10 CFU/100 mL on average compared to shorter pumping intervals (5 min). Though the treated water did not comply with the World Health Organization standards of 0 CFU/100 mL, the filter significantly improved water quality and provided one of the best sources of drinkable water in a water...

  17. Turbulence-cascade interaction noise using an advanced digital filter method

    OpenAIRE

    Gea Aguilera, Fernando; Gill, James; Zhang, Xin; Nodé-Langlois, Thomas

    2016-01-01

    Fan wakes interacting with outlet guide vanes is a major source of noise in modern turbofan engines. In order to study this source of noise, the current work presents two-dimensional simulations of turbulence-cascade interaction noise using a computational aeroacoustic methodology. An advanced digital filter method is used for the generation of isotropic synthetic turbulence in a linearised Euler equation solver. A parameter study is presented to assess the influence of airfoil thickness, mea...

  18. Protecting nickel with graphene spin-filtering membranes: A single layer is enough

    Energy Technology Data Exchange (ETDEWEB)

    Martin, M.-B.; Dlubak, B.; Piquemal-Banci, M.; Collin, S.; Petroff, F.; Anane, A.; Fert, A.; Seneor, P. [Unité Mixte de Physique CNRS/Thales, 1 Avenue Augustin Fresnel, 91767 Palaiseau, France and Université Paris Sud, 91405 Orsay (France); Weatherup, R. S.; Hofmann, S.; Robertson, J. [Department of Engineering, University of Cambridge, Cambridge CB21PZ (United Kingdom); Yang, H. [IBS Center for Integrated Nanostructure Physics (CINAP), Institute for Basic Science, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of); Department of Energy Science, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of); Blume, R. [Helmholtz-Zentrum Berlin fur Materialien und Energie, 12489 Berlin (Germany); Schloegl, R. [Department of Inorganic Chemistry, Fritz Haber Institute of the Max Planck Society, Faradayweg 4-6, 14195 Berlin (Germany)

    2015-07-06

    We report on the demonstration of ferromagnetic spin injectors for spintronics which are protected against oxidation through passivation by a single layer of graphene. The graphene monolayer is directly grown by catalytic chemical vapor deposition on pre-patterned nickel electrodes. X-ray photoelectron spectroscopy reveals that even with its monoatomic thickness, monolayer graphene still efficiently protects spin sources against oxidation in ambient air. The resulting single layer passivated electrodes are integrated into spin valves and demonstrated to act as spin polarizers. Strikingly, the atom-thick graphene layer is shown to be sufficient to induce a characteristic spin filtering effect evidenced through the sign reversal of the measured magnetoresistance.

  19. Spectroscopic analysis and dosimetry of diagnostic x-ray beams filtered by rare earth materials

    International Nuclear Information System (INIS)

    Tyndall, D.A.

    1986-01-01

    A laboratory investigation was carried out to assess the effect of various types of rare earth filter materials on the energy spectrum and concomitant reduced exposure values of diagnostic x-ray beams at 70, 80, and 90 kVp. An x-ray spectroscope was constructed and used to generate the energy spectra of beams passing through the various rare earth filter materials. Photographs were made of each spectrum, and live-time gross photon counts were recorded. Following spectral determinations, ionization chamber readings were generated for each filter material. Substantial effects on x-ray spectra and reduction of exposure values were noted. The degree of these effects were dependent on the atomic number, k-edge, and thickness of each filter. Metallic forms of rare earth materials proved to be more effective than the salt forms with erbium offering the greatest potential for reduction in exposures over the range of experimental kilovolt (peak) values

  20. X-ray fluorescence determination of Au, Pd and Pt from chloride solutions after preconcentration on cellulose filters

    International Nuclear Information System (INIS)

    Gordeeva, V.P.; Glazkova, S.V.; Tsysin, G.I.; Ivanov, V.M.; Zolotov, Yu. A.

    2003-01-01

    The aim of this work was synthesis of new sorption cellulose filters for dynamic preconcentration of Au, Pd and Pt from chloride solutions and subsequent XRF determination of these elements on the filters. New filters were prepared by impregnation of a filter paper with solution of tri-n-octylamine and paraffin in hexane (TOA-filters). The effect of paraffin and TOA concentration in hexane on a content of nitrogen in a filter was studied. It was found that Au(III), Pd(II) and Pt(IV) were quantitatively recovered on the TOA-filters (filtering surface diameter of 23 mm, thickness of 0.15 mm) from 0.5 - 1 M HCl at a flow rates of 2-5 ml min-1 from 10-100 ml of solution. The mathematical model of sorption dynamics was offered for the estimation of potential possibilities of new impregnated sorbents and for the evaluation of optimum dynamic conditions allowing to achieve of maximum concentration efficiency (CE max ). The elements were determined directly on the filters by XRF spectrometer. Palladium was also determined on the TOA-filters after formation of coloured compounds of metal with 4-(2-pyridylazo)resorcinol (PAR) by diffuse reflectance spectroscopy with the calculation of calorimetric characteristics and using test-scale. (authors)

  1. Optimization of the k-edge filters utilization in the dental radiographs; Otimizacao da utilizacao dos filtros de aresta K na radiografias dentarias

    Energy Technology Data Exchange (ETDEWEB)

    Reyes, Luis M.G.; Almeida, Adelaide de [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Faculdade de Filosofia, Ciencias e Letras. Dept. de Fisica e Matematica

    2001-07-01

    The signal to noise ratio (S/N) of radiographic film images may be optimized if the thicknesses and atomic composition of the structures to be analyzed are known. With specifications and a knowledge of the interaction of photons with the materials, the photon energy for maximum contrast may be determined. We propose a K-edge filter in addition to the normal aluminum filter, to reduce the dose to the patient by the transmission of a narrow spectrum of photons with energies to optimize the image contrast. The optimum photon energy to obtain the best contrast between dental pulp and dentine and between dentine and dental enamel was determined to be 29-34 and 22-26 keV respectively. The filter material, which closely approximates these spectra, is made of Ce (Z=58) whose thickness is shown do depend on the parameters of the X-ray generator. (author)

  2. Filter effectiveness in the manufacture of high-chromium steel castings

    Directory of Open Access Journals (Sweden)

    M. Garbiak

    2011-01-01

    Full Text Available The paper presents the results of studies on the application of ceramic filters in the manufacture of cast hearth plates at the WestPomeranian University of Technology in Szczecin. Castings were poured from the heat-resistant G-X40CrNiSi27-4 cast steel in greensand moulds. The development of casting manufacturing technology included the following studies: analysis of the causes of nonmetallicinclusions in high-chromium alloys, computer simulation of mould filling with liquid metal using standard gating systems without filters and new systems with the built-in filter, making pilot castings, quantitative determination of the content of non-metallicinclusions, determination of the oxygen and nitrogen content, and evaluation of the extent of occurrence of the raw casting s urfacedefects. As a result of the conducted studies and analyses, the quality of produced castings was improved, mainly through the reducedcontent of non-metallic inclusions and better raw casting surface quality.

  3. Full-color large-scaled computer-generated holograms using RGB color filters.

    Science.gov (United States)

    Tsuchiyama, Yasuhiro; Matsushima, Kyoji

    2017-02-06

    A technique using RGB color filters is proposed for creating high-quality full-color computer-generated holograms (CGHs). The fringe of these CGHs is composed of more than a billion pixels. The CGHs reconstruct full-parallax three-dimensional color images with a deep sensation of depth caused by natural motion parallax. The simulation technique as well as the principle and challenges of high-quality full-color reconstruction are presented to address the design of filter properties suitable for large-scaled CGHs. Optical reconstructions of actual fabricated full-color CGHs are demonstrated in order to verify the proposed techniques.

  4. Surgical Management of the Thick-Skinned Nose.

    Science.gov (United States)

    Davis, Richard E; Hrisomalos, Emily N

    2018-02-01

    When executed properly, open structure rhinoplasty can dramatically improve the consistency, durability, and quality of the cosmetic surgical outcome. Moreover, in expert hands, dramatic transformations in skeletal architecture can be accomplished with minimal risk and unparalleled control, all while preserving nasal airway function. While skeletal enhancements have become increasingly more controlled and precise, the outer skin-soft tissue envelope (SSTE) often presents a formidable obstacle to a satisfactory cosmetic result. In noses with unusually thick skin, excessive skin volume and characteristically hostile healing responses frequently combine to obscure or sometimes even negate cosmetic skeletal modifications and taint the surgical outcome. For this challenging patient subgroup, care must be taken to optimize the SSTE using a graduated treatment strategy directed at minimizing skin thickness and controlling unfavorable healing responses. When appropriate efforts are implemented to manage thick nasal skin, cosmetic outcomes are often substantially improved, sometimes even negating the ill-effects of thick skin altogether. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  5. Dynamical noise filter and conditional entropy analysis in chaos synchronization.

    Science.gov (United States)

    Wang, Jiao; Lai, C-H

    2006-06-01

    It is shown that, in a chaotic synchronization system whose driving signal is exposed to channel noise, the estimation of the drive system states can be greatly improved by applying the dynamical noise filtering to the response system states. If the noise is bounded in a certain range, the estimation errors, i.e., the difference between the filtered responding states and the driving states, can be made arbitrarily small. This property can be used in designing an alternative digital communication scheme. An analysis based on the conditional entropy justifies the application of dynamical noise filtering in generating quality synchronization.

  6. Characteristics of poly- and mono-crystalline BeO and SiO{sub 2} as thermal and cold neutron filters

    Energy Technology Data Exchange (ETDEWEB)

    Adib, M.; Habib, N. [Reactor Physics Department, NRC, Atomic Energy Authority, Cairo (Egypt); Bashter, I.I. [Physics Department, Faculty of Science, Zagazig University (Egypt); Morcos, H.N.; El-Mesiry, M.S. [Reactor Physics Department, NRC, Atomic Energy Authority, Cairo (Egypt); Mansy, M.S., E-mail: drmohamedmansy88@hotmail.com [Reactor Physics Department, NRC, Atomic Energy Authority, Cairo (Egypt)

    2015-09-01

    Highlights: • Neutron filtering features of BeO and SiO{sub 2} poly- and mono-crystals. • Calculations of the cold and thermal neutron cross sections and transmission with the code “HEXA-FILTERS”. • Optimal mosaic spread, thicknesses and cutting planes for BeO and SiO{sub 2} mono-crystals. - Abstract: A simple model along with a computer code “HEXA-FILTERS” is used to carry out the calculation of the total cross-sections of BeO and SiO{sub 2} having poly or mono-crystalline form as a function of neutron wavelength at room (R.T.) and liquid nitrogen (L.N.) temperatures. An overall agreement is indicated between the calculated neutron cross-sections and experimental data. Calculation shows that 25 cm thick of polycrystalline BeO cooled at liquid nitrogen temperature was found to be a good filter for neutron wavelengths longer than 0.46 nm. While, 50 cm of SiO{sub 2}, with much less transmission, for neutrons with wavelengths longer than 0.85 nm. It was also found that 10 cm of BeO and 15 cm SiO{sub 2} thick mono-crystals cut along their (0 0 2) plane, with 0.5° FWHM on mosaic spread and cooled at L.N., are a good thermal neutron filter, with high effect-to-noise ratio.

  7. Tunable dual-channel filter based on the photonic crystal with air defects.

    Science.gov (United States)

    Zhao, Xiaodan; Yang, Yibiao; Wen, Jianhua; Chen, Zhihui; Zhang, Mingda; Fei, Hongming; Hao, Yuying

    2017-07-01

    We propose a tuning filter containing two channels by inserting a defect layer (Air/Si/Air/Si/Air) into a one-dimensional photonic crystal of Si/SiO 2 , which is on the symmetry of the defect. Two transmission peaks (1528.98 and 1564.74 nm) appear in the optical communication S-band and C-band, and the transmittance of these two channels is up to 100%. In addition, this design realizes multi-channel filtering to process large dynamic range or multiple independent signals in the near-infrared band by changing the structure. The tuning range will be enlarged, and the channels can be moved in this range through the easy control of air thickness and incident angle.

  8. Field application of farmstead runoff to vegetated filter strips: surface and subsurface water quality assessment.

    Science.gov (United States)

    Larson, Rebecca A; Safferman, Steven I

    2012-01-01

    Farmstead runoff poses significant environmental impacts to ground and surface waters. Three vegetated filter strips were assessed for the treatment of dairy farmstead runoff at the soil surface and subsurface at 0.3- or 0. 46-m and 0. 76-m depths for numerous storm events. A medium-sized Michigan dairy was retrofitted with two filter strips on sandy loam soil and a third filter strip was implemented on a small Michigan dairy with sandy soil to collect and treat runoff from feed storage, manure storage, and other impervious farmstead areas. All filter strips were able to eliminate surface runoff via infiltration for all storm events over the duration of the study, eliminating pollutant contributions to surface water. Subsurface effluent was monitored to determine the contributing groundwater concentrations of numerous pollutants including chemical oxygen demand (COD), metals, and nitrates. Subsurface samples have an average reduction of COD concentrations of 20, 11, and 85% for the medium dairy Filter Strip 1 (FS1), medium dairy Filter Strip 2 (FS2), and the small Michigan dairy respectively, resulting in average subsurface concentrations of 355, 3960, and 718 mg L COD. Similar reductions were noted for ammonia and total Kjeldahl nitrogen (TKN) in the subsurface effluent. The small Michigan dairy was able to reduce the pollutant leachate concentrations of COD, TKN, and ammonia over a range of influent concentrations. Increased influent concentrations in the medium Michigan dairy filter strips resulted in an increase in COD, TKN, and ammonia concentrations in the leachate. Manganese was leached from the native soils at all filter strips as evidenced by the increase in manganese concentrations in the leachate. Nitrate concentrations were above standard drinking water limits (10 mg L), averaging subsurface concentrations of 11, 45, and 25 mg L NO-N for FS1, FS2, and the small Michigan dairy, respectively. Copyright © by the American Society of Agronomy, Crop Science

  9. Image Recommendation Algorithm Using Feature-Based Collaborative Filtering

    Science.gov (United States)

    Kim, Deok-Hwan

    As the multimedia contents market continues its rapid expansion, the amount of image contents used in mobile phone services, digital libraries, and catalog service is increasing remarkably. In spite of this rapid growth, users experience high levels of frustration when searching for the desired image. Even though new images are profitable to the service providers, traditional collaborative filtering methods cannot recommend them. To solve this problem, in this paper, we propose feature-based collaborative filtering (FBCF) method to reflect the user's most recent preference by representing his purchase sequence in the visual feature space. The proposed approach represents the images that have been purchased in the past as the feature clusters in the multi-dimensional feature space and then selects neighbors by using an inter-cluster distance function between their feature clusters. Various experiments using real image data demonstrate that the proposed approach provides a higher quality recommendation and better performance than do typical collaborative filtering and content-based filtering techniques.

  10. Data Quality Screening Service

    Science.gov (United States)

    Strub, Richard; Lynnes, Christopher; Hearty, Thomas; Won, Young-In; Fox, Peter; Zednik, Stephan

    2013-01-01

    A report describes the Data Quality Screening Service (DQSS), which is designed to help automate the filtering of remote sensing data on behalf of science users. Whereas this process often involves much research through quality documents followed by laborious coding, the DQSS is a Web Service that provides data users with data pre-filtered to their particular criteria, while at the same time guiding the user with filtering recommendations of the cognizant data experts. The DQSS design is based on a formal semantic Web ontology that describes data fields and the quality fields for applying quality control within a data product. The accompanying code base handles several remote sensing datasets and quality control schemes for data products stored in Hierarchical Data Format (HDF), a common format for NASA remote sensing data. Together, the ontology and code support a variety of quality control schemes through the implementation of the Boolean expression with simple, reusable conditional expressions as operands. Additional datasets are added to the DQSS simply by registering instances in the ontology if they follow a quality scheme that is already modeled in the ontology. New quality schemes are added by extending the ontology and adding code for each new scheme.

  11. Metal cutting by radiation from a CO2 laser with a self-filtering cavity

    International Nuclear Information System (INIS)

    Malikov, A G; Orishich, Anatolii M; Shulyat'ev, Viktor B

    2009-01-01

    The possibility of quality cutting by radiation from a CO 2 laser with an unstable self-filtering cavity (SFC) is experimentally investigated. The SFC provides the product of the divergence angle by the beam radius close to that for lower modes in a stable cavity (SC), however, at a higher radiation power, which favours faster cutting. In the far-field zone, the SFC beam has a diffraction structure with side maxima, which is usually considered as a negative factor in laser cutting. 25-mm-thick steel slabs have been cut. The comparison of the obtained results with known data on SC lasers shows that the principal characteristics of the cut (the width, edge roughness, specific expenditure of energy) are close in these lasers. A conclusion is made that at the chosen cavity parameters, the specific spatial structure of the SFC laser beam has no significant effect on the cut characteristics. (laser technologies)

  12. A Tunable Low Noise Active Bandpass Filter Using a Noise Canceling Technique

    OpenAIRE

    Soltani, N.

    2016-01-01

    A monolithic tunable low noise active bandpass filter is presented in this study. Biasing voltages can control the center frequency and quality factor. By keeping the gain constant, the center frequency shift is 300 MHz. The quality factor can range from 90 to 290 at the center frequency. By using a noise cancelling circuit, noise is kept lower than 2.8 dB. The proposed filter is designed using MMIC technology with a center frequency of 2.4 GHz and a power consumption of 180 mW. ED02AH techno...

  13. Harmonic Active Filtering and Impedance-based Stability Analysis in Offshore Wind Power Plants

    DEFF Research Database (Denmark)

    Dhua, Debasish; Yang, Guangya; Zhang, Zhe

    2017-01-01

    installation and provides effectively similar functionality as passive filters. This work is focused on harmonic propagation studies in wind power plants, power quality evaluation at the point of connection and harmonic mitigation by active filtering. Finally, an impedance-based stability analysis......Nowadays, to eliminate harmonics injected by the wind turbines in offshore wind power plants there is a need to install passive filters. Moreover, the passive filters are not adaptive to harmonic profile changes due to topology changes, grid loading etc. Therefore, active filters in wind turbines...... are proposed as a flexible harmonic mitigation measure. The motivation of this study is to explore the possibility of embedding active filtering in wind turbine grid-side converters without having to change the system electrical infrastructure. The active filtering method can prevent additional equipment...

  14. Liquid Metal Droplet and Micro Corrugated Diaphragm RF-MEMS for reconfigurable RF filters

    Science.gov (United States)

    Irshad, Wasim

    detail and have proved pivotal to this work. The second part of the dissertation focuses on the Liquid Metal Droplet RF-MEMS. A novel tunable RF MEMS resonator that is based upon electrostatic control over the morphology of a liquid metal droplet (LMD) is conceived. We demonstrate an LMD evanescent-mode cavity resonator that simultaneously achieves wide analog tuning from 12 to 18 GHz with a measured quality factor of 1400-1840. A droplet of 250-mum diameter is utilized and the applied bias is limited to 100 V. This device operates on a principle called Electro-Wetting On Dielectric (EWOD). The liquid metal employed is a non-toxic eutectic alloy of Gallium, Indium and Tin known as Galinstan. This device also exploits interfacial surface energy and viscous body forces that dominate at nanoliter scale. We then apply our Liquid Metal Droplet (LMD) RF-MEMS architecture to demonstrate a continuously tunable electrostatic Ku-Band Filter. A 2-pole bandpass filter with measured insertion loss of less than 0.4dB and 3dB FBW of 3.4% is achieved using a Galinstan droplet of 250mum diameter and bias limited to 100V. We demonstrate that the LMD is insensitive to gravity by performing inversion and tilt experiments. In addition, we study its thermal tolerance by subjecting the LMD up to 150° C. The third part of the dissertation is dedicated to the Micro-Corrugated Diaphragm (MCD) RF-MEMS. We present an evanescent-mode cavity bandpass filter with state-of-the-art RF performance metrics like 4:1 tuning ratio from 5 to 20 GHz with less than 2dB insertion loss and 2-6% 3dB bandwidth. Micro-Corrugated Diaphragm (MCD) is a novel electrostatic MEMS design specifically engineered to provide large-scale analog deflections necessary for such continuous and wide tunable filtering with very high quality factor. We demonstrate a 1.25mm radius and 2mum thick Gold MCD which provides 30mum total deflection with nearly 60% analog range. We also present a detailed and systematic MCD design

  15. Design of Nonuniform Filter Bank Transceivers for Frequency Selective Channels

    Directory of Open Access Journals (Sweden)

    Yuan-Pei Lin

    2007-01-01

    Full Text Available In recent years, there has been considerable interest in the theory and design of filter bank transceivers due to their superior frequency response. In many applications, it is desired to have transceivers that can support multiple services with different incoming data rates and different quality-of-service requirements. To meet these requirements, we can either do resource allocation or design transceivers with a nonuniform bandwidth partition. In this paper, we propose a method for the design of nonuniform filter bank transceivers for frequency selective channels. Both frequency response and signal-to-interference ratio (SIR can be incorporated in the transceiver design. Moreover, the technique can be extended to the case of nonuniform filter bank transceivers with rational sampling factors. Simulation results show that nonuniform filter bank transceivers with good filter responses as well as high SIR can be obtained by the proposed design method.

  16. Analysis of quality raw data of second generation sequencers with Quality Assessment Software.

    Science.gov (United States)

    Ramos, Rommel Tj; Carneiro, Adriana R; Baumbach, Jan; Azevedo, Vasco; Schneider, Maria Pc; Silva, Artur

    2011-04-18

    Second generation technologies have advantages over Sanger; however, they have resulted in new challenges for the genome construction process, especially because of the small size of the reads, despite the high degree of coverage. Independent of the program chosen for the construction process, DNA sequences are superimposed, based on identity, to extend the reads, generating contigs; mismatches indicate a lack of homology and are not included. This process improves our confidence in the sequences that are generated. We developed Quality Assessment Software, with which one can review graphs showing the distribution of quality values from the sequencing reads. This software allow us to adopt more stringent quality standards for sequence data, based on quality-graph analysis and estimated coverage after applying the quality filter, providing acceptable sequence coverage for genome construction from short reads. Quality filtering is a fundamental step in the process of constructing genomes, as it reduces the frequency of incorrect alignments that are caused by measuring errors, which can occur during the construction process due to the size of the reads, provoking misassemblies. Application of quality filters to sequence data, using the software Quality Assessment, along with graphing analyses, provided greater precision in the definition of cutoff parameters, which increased the accuracy of genome construction.

  17. Performance evaluation of a dual-flow recharge filter for improving groundwater quality.

    Science.gov (United States)

    Samuel, Manoj P; Senthilvel, S; Mathew, Abraham C

    2014-07-01

    A dual-flow multimedia stormwater filter integrated with a groundwater recharge system was developed and tested for hydraulic efficiency and pollutant removal efficiency. The influent stormwater first flows horizontally through the circular layers of planted grass and biofibers. Subsequently, the flow direction changes to a vertical direction so that water moves through layers of pebbles and sand and finally gets recharged to the deep aquifers. The media in the sequence of vegetative medium:biofiber to pebble:sand were filled in nine proportions and tested for the best performing combination. Three grass species, viz., Typha (Typha angustifolia), Vetiver (Chrysopogon zizanioides), and St. Augustine grass (Stenotaphrum secundatum), were tested as the best performing vegetative medium. The adsorption behavior of Coconut (Cocos nucifera) fiber, which was filled in the middle layer, was determined by a series of column and batch studies.The dual-flow filter showed an increasing trend in hydraulic efficiency with an increase in flowrate. The chemical removal efficiency of the recharge dual-flow filter was found to be very high in case of K+ (81.6%) and Na+ (77.55%). The pH normalizing efficiency and electrical conductivity reduction efficiency were also recorded as high. The average removal percentage of Ca2+ was moderate, while that of Mg2+ was very low. The filter proportions of 1:1 to 1:2 (plant:fiber to pebble:sand) showed a superior performance compared to all other proportions. Based on the estimated annual costs and returns, all the financial viability criteria (internal rate of return, net present value, and benefit-cost ratio) were found to be favorable and affordable to farmers in terms of investing in the developed filtration system.

  18. Simulation model of harmonics reduction technique using shunt active filter by cascade multilevel inverter method

    Science.gov (United States)

    Andreh, Angga Muhamad; Subiyanto, Sunardiyo, Said

    2017-01-01

    Development of non-linear loading in the application of industry and distribution system and also harmonic compensation becomes important. Harmonic pollution is an urgent problem in increasing power quality. The main contribution of the study is the modeling approach used to design a shunt active filter and the application of the cascade multilevel inverter topology to improve the power quality of electrical energy. In this study, shunt active filter was aimed to eliminate dominant harmonic component by injecting opposite currents with the harmonic component system. The active filter was designed by shunt configuration with cascaded multilevel inverter method controlled by PID controller and SPWM. With this shunt active filter, the harmonic current can be reduced so that the current wave pattern of the source is approximately sinusoidal. Design and simulation were conducted by using Power Simulator (PSIM) software. Shunt active filter performance experiment was conducted on the IEEE four bus test system. The result of shunt active filter installation on the system (IEEE four bus) could reduce THD current from 28.68% to 3.09%. With this result, the active filter can be applied as an effective method to reduce harmonics.

  19. Quality of life and female sexual function after skinning vulvectomy with split-thickness skin graft in women with vulvar intraepithelial neoplasia or vulvar Paget disease.

    Science.gov (United States)

    Lavoué, V; Lemarrec, A; Bertheuil, N; Henno, S; Mesbah, H; Watier, E; Levêque, J; Morcel, K

    2013-12-01

    Vulvar intraepithelial neoplasia (VIN) and vulvar Paget disease are managed with either vulvectomy, destructive treatments (laser, antimitotic drugs) or immunostimulants. All these options are associated with functional complications. The purpose of this study was to evaluate the surgical technique consisting of skinning vulvectomy with split-thickness skin graft, and its effect on overall quality of life and sexual function. A retrospective study was conducted on thirteen patients who underwent skinning vulvectomy with split-thickness skin graft between 1999 and 2009. Overall quality of life and sexual function were assessed with the Medical Outcome Study Short Form 36 (MOS SF-36) and Female Sexual Function Index (FSFI), respectively. The median age of patients was 54 (range: 33-77) years. Three patients had Paget disease and 10 patients had VIN lesions. The excision margins were clear in 46% of cases. The incidence of occult cancer was 31%. The mean follow-up period was 77 (±35) months. Four patients experienced a relapse of their intraepithelial disease. The mean disease-free survival was 58 (±44) months. There was no significant difference in MOS SF-36 scores between the study population and the general population. The patients assessed with the FSFI regained normal sexual function after the surgical procedure. Skinning vulvectomy with split-thickness skin graft is a feasible technique yielding good results in terms of quality of life and sexual function. It enables occult cancer to be diagnosed in patients with VIN or Paget disease. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Experimental study of filter cake formation on different filter media

    International Nuclear Information System (INIS)

    Saleem, M.

    2009-01-01

    Removal of particulate matter from gases generated in the process industry is important for product recovery as well as emission control. Dynamics of filtration plant depend on operating conditions. The models, that predict filter plant behaviour, involve empirical resistance parameters which are usually derived from limited experimental data and are characteristics of the filter media and filter cake (dust deposited on filter medium). Filter cake characteristics are affected by the nature of filter media, process parameters and mode of filter regeneration. Removal of dust particles from air is studied in a pilot scale jet pulsed bag filter facility resembling closely to the industrial filters. Limestone dust and ambient air are used in this study with two widely different filter media. All important parameters like pressure drop, gas flow rate, dust settling, are recorded continuously at 1s interval. The data is processed for estimation of the resistance parameters. The pressure drop rise on test filter media is compared. Results reveal that the surface of filter media has an influence on pressure drop rise (concave pressure drop rise). Similar effect is produced by partially jet pulsed filter surface. Filter behaviour is also simulated using estimated parameters and a simplified model and compared with the experimental results. Distribution of cake area load is therefore an important aspect of jet pulse cleaned bag filter modeling. Mean specific cake resistance remains nearly constant on thoroughly jet pulse cleaned membrane coated filter bags. However, the trend can not be confirmed without independent cake height and density measurements. Thus the results reveal the importance of independent measurements of cake resistance. (author)

  1. MST Filterability Tests

    Energy Technology Data Exchange (ETDEWEB)

    Poirier, M. R. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Burket, P. R. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Duignan, M. R. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-03-12

    The Savannah River Site (SRS) is currently treating radioactive liquid waste with the Actinide Removal Process (ARP) and the Modular Caustic Side Solvent Extraction Unit (MCU). The low filter flux through the ARP has limited the rate at which radioactive liquid waste can be treated. Recent filter flux has averaged approximately 5 gallons per minute (gpm). Salt Batch 6 has had a lower processing rate and required frequent filter cleaning. Savannah River Remediation (SRR) has a desire to understand the causes of the low filter flux and to increase ARP/MCU throughput. In addition, at the time the testing started, SRR was assessing the impact of replacing the 0.1 micron filter with a 0.5 micron filter. This report describes testing of MST filterability to investigate the impact of filter pore size and MST particle size on filter flux and testing of filter enhancers to attempt to increase filter flux. The authors constructed a laboratory-scale crossflow filter apparatus with two crossflow filters operating in parallel. One filter was a 0.1 micron Mott sintered SS filter and the other was a 0.5 micron Mott sintered SS filter. The authors also constructed a dead-end filtration apparatus to conduct screening tests with potential filter aids and body feeds, referred to as filter enhancers. The original baseline for ARP was 5.6 M sodium salt solution with a free hydroxide concentration of approximately 1.7 M.3 ARP has been operating with a sodium concentration of approximately 6.4 M and a free hydroxide concentration of approximately 2.5 M. SRNL conducted tests varying the concentration of sodium and free hydroxide to determine whether those changes had a significant effect on filter flux. The feed slurries for the MST filterability tests were composed of simple salts (NaOH, NaNO2, and NaNO3) and MST (0.2 – 4.8 g/L). The feed slurry for the filter enhancer tests contained simulated salt batch 6 supernate, MST, and filter enhancers.

  2. Sci-Thur AM: YIS – 07: Optimizing dual-energy x-ray parameters using a single filter for both high and low-energy images to enhance soft-tissue imaging

    International Nuclear Information System (INIS)

    Bowman, Wesley; Sattarivand, Mike

    2016-01-01

    Objective: To optimize dual-energy parameters of ExacTrac stereoscopic x-ray imaging system for lung SBRT patients Methods: Simulated spectra and a lung phantom were used to optimize filter material, thickness, kVps, and weighting factors to obtain bone subtracted dual-energy images. Spektr simulations were used to identify material in the atomic number (Z) range [3–83] based on a metric defined to separate spectrums of high and low energies. Both energies used the same filter due to time constraints of image acquisition in lung SBRT imaging. A lung phantom containing bone, soft tissue, and a tumor mimicking material was imaged with filter thicknesses range [0–1] mm and kVp range [60–140]. A cost function based on contrast-to-noise-ratio of bone, soft tissue, and tumor, as well as image noise content, was defined to optimize filter thickness and kVp. Using the optimized parameters, dual-energy images of anthropomorphic Rando phantom were acquired and evaluated for bone subtraction. Imaging dose was measured with dual-energy technique using tin filtering. Results: Tin was the material of choice providing the best energy separation, non-toxicity, and non-reactiveness. The best soft-tissue-only image in the lung phantom was obtained using 0.3 mm tin and [140, 80] kVp pair. Dual-energy images of the Rando phantom had noticeable bone elimination when compared to no filtration. Dose was lower with tin filtering compared to no filtration. Conclusions: Dual-energy soft-tissue imaging is feasible using ExacTrac stereoscopic imaging system utilizing a single tin filter for both high and low energies and optimized acquisition parameters.

  3. Sci-Thur AM: YIS – 07: Optimizing dual-energy x-ray parameters using a single filter for both high and low-energy images to enhance soft-tissue imaging

    Energy Technology Data Exchange (ETDEWEB)

    Bowman, Wesley; Sattarivand, Mike [Department of Radiation Oncology, Dalhousie University at Nova Scotia Health Authority, Department of Radiation Oncology, Dalhousie University at Nova Scotia Health Authority (Canada)

    2016-08-15

    Objective: To optimize dual-energy parameters of ExacTrac stereoscopic x-ray imaging system for lung SBRT patients Methods: Simulated spectra and a lung phantom were used to optimize filter material, thickness, kVps, and weighting factors to obtain bone subtracted dual-energy images. Spektr simulations were used to identify material in the atomic number (Z) range [3–83] based on a metric defined to separate spectrums of high and low energies. Both energies used the same filter due to time constraints of image acquisition in lung SBRT imaging. A lung phantom containing bone, soft tissue, and a tumor mimicking material was imaged with filter thicknesses range [0–1] mm and kVp range [60–140]. A cost function based on contrast-to-noise-ratio of bone, soft tissue, and tumor, as well as image noise content, was defined to optimize filter thickness and kVp. Using the optimized parameters, dual-energy images of anthropomorphic Rando phantom were acquired and evaluated for bone subtraction. Imaging dose was measured with dual-energy technique using tin filtering. Results: Tin was the material of choice providing the best energy separation, non-toxicity, and non-reactiveness. The best soft-tissue-only image in the lung phantom was obtained using 0.3 mm tin and [140, 80] kVp pair. Dual-energy images of the Rando phantom had noticeable bone elimination when compared to no filtration. Dose was lower with tin filtering compared to no filtration. Conclusions: Dual-energy soft-tissue imaging is feasible using ExacTrac stereoscopic imaging system utilizing a single tin filter for both high and low energies and optimized acquisition parameters.

  4. Molecular surface mesh generation by filtering electron density map.

    Science.gov (United States)

    Giard, Joachim; Macq, Benoît

    2010-01-01

    Bioinformatics applied to macromolecules are now widely spread and in continuous expansion. In this context, representing external molecular surface such as the Van der Waals Surface or the Solvent Excluded Surface can be useful for several applications. We propose a fast and parameterizable algorithm giving good visual quality meshes representing molecular surfaces. It is obtained by isosurfacing a filtered electron density map. The density map is the result of the maximum of Gaussian functions placed around atom centers. This map is filtered by an ideal low-pass filter applied on the Fourier Transform of the density map. Applying the marching cubes algorithm on the inverse transform provides a mesh representation of the molecular surface.

  5. Molecular Surface Mesh Generation by Filtering Electron Density Map

    Directory of Open Access Journals (Sweden)

    Joachim Giard

    2010-01-01

    Full Text Available Bioinformatics applied to macromolecules are now widely spread and in continuous expansion. In this context, representing external molecular surface such as the Van der Waals Surface or the Solvent Excluded Surface can be useful for several applications. We propose a fast and parameterizable algorithm giving good visual quality meshes representing molecular surfaces. It is obtained by isosurfacing a filtered electron density map. The density map is the result of the maximum of Gaussian functions placed around atom centers. This map is filtered by an ideal low-pass filter applied on the Fourier Transform of the density map. Applying the marching cubes algorithm on the inverse transform provides a mesh representation of the molecular surface.

  6. Calibration and use of filter test facility orifice plates

    Science.gov (United States)

    Fain, D. E.; Selby, T. W.

    1984-07-01

    There are three official DOE filter test facilities. These test facilities are used by the DOE, and others, to test nuclear grade HEPA filters to provide Quality Assurance that the filters meet the required specifications. The filters are tested for both filter efficiency and pressure drop. In the test equipment, standard orifice plates are used to set the specified flow rates for the tests. There has existed a need to calibrate the orifice plates from the three facilities with a common calibration source to assure that the facilities have comparable tests. A project has been undertaken to calibrate these orifice plates. In addition to reporting the results of the calibrations of the orifice plates, the means for using the calibration results will be discussed. A comparison of the orifice discharge coefficients for the orifice plates used at the seven facilities will be given. The pros and cons for the use of mass flow or volume flow rates for testing will be discussed. It is recommended that volume flow rates be used as a more practical and comparable means of testing filters. The rationale for this recommendation will be discussed.

  7. Efficient Filtering of Noisy Fingerprint Images

    Directory of Open Access Journals (Sweden)

    Maria Liliana Costin

    2016-01-01

    Full Text Available Fingerprint identification is an important field in the wide domain of biometrics with many applications, in different areas such: judicial, mobile phones, access systems, airports. There are many elaborated algorithms for fingerprint identification, but none of them can guarantee that the results of identification are always 100 % accurate. A first step in a fingerprint image analysing process consists in the pre-processing or filtering. If the result after this step is not by a good quality the upcoming identification process can fail. A major difficulty can appear in case of fingerprint identification if the images that should be identified from a fingerprint image database are noisy with different type of noise. The objectives of the paper are: the successful completion of the noisy digital image filtering, a novel more robust algorithm of identifying the best filtering algorithm and the classification and ranking of the images. The choice about the best filtered images of a set of 9 algorithms is made with a dual method of fuzzy and aggregation model. We are proposing through this paper a set of 9 filters with different novelty designed for processing the digital images using the following methods: quartiles, medians, average, thresholds and histogram equalization, applied all over the image or locally on small areas. Finally the statistics reveal the classification and ranking of the best algorithms.

  8. Reduksi Harmonisa Pada Uninterruptible Power Supply (UPS) Dengan Single Tuned Passive Filter

    OpenAIRE

    Nasution, Agus Almi

    2017-01-01

    Using non-linier load in Uninterruptible Power Supply (UPS) can cause harmonic distortion which will eventually have the effect on power quality. The research was designed as a single-turned passive filter to cope will harmonic distortion in UPS. In this phase, THDv, THDi, and IHDi were measured in UPS. MATLAB/Simulink was used for simulation of filter testing. After single-turned passive filter was installed, the third order of harmonic current decreased from 47,69% to 7,08% or reduced 40.61...

  9. Bacteria in non-woven textile filters for domestic wastewater treatment.

    Science.gov (United States)

    Spychała, Marcin; Starzyk, Justyna

    2015-01-01

    The objective of this study was preliminary identification of heterotrophic and ammonia oxidizing bacteria (AOB) cell concentration in the cross-sectional profile of geotextile filters for wastewater treatment. Filters of thicknesses 3.6 and 7.2 mm, made of non-woven textile TS20, were supplied with septic tank effluent and intermittently dosed and filtered under hydrostatic pressure. The cumulative loads of chemical oxygen demand (COD) and total solids were about 1.36 and 1.06 kg/cm2, respectively. The filters under analysis reached a relatively high removal efficiency for organic pollution 70-90% for biochemical oxygen demand (BOD5) and 60-85% for COD. The ammonia nitrogen removal efficiency level proved to be unstable (15-55%). Biomass samples for dry mass identification were taken from two regions: continuously flooded with wastewater and intermittently flooded with wastewater. The culturable heterotrophic bacteria were determined as colony-forming units (CFUs) on microbiological-selective media by means of the plate method. AOB and nitrite oxidizing bacteria (NOB) were examined using the FISH technique. A relatively wide range of heterotrophic bacteria was observed from 7.4×10(5)/cm2 to 3.8×10(6)/cm2 in geotextile layers. The highest concentration of heterotrophic bacteria (3.8×10(6)/cm2) was observed in the first layer of the textile filter. AOB were identified occasionally--about 8-15% of all bacteria colonizing the last filter layer, but occasionally much higher concentrations and ammonia nitrogen efficiency were achieved. Bacteria oxidizing nitrite to nitrate were not observed. The relation of total and organic fraction of biomass to culturable heterotrophic bacteria was also found.

  10. Estimation of average glandular dose depending on the thickness of the breast

    International Nuclear Information System (INIS)

    Real, Jessica V.; Luz, Renata M. da; Fröhlich, Bruna D.; Pertile, Alessandra S.; Silva, Ana Maria Marques da

    2014-01-01

    Breast cancer is the most common type of cancer in women worldwide. Mammography is, to date, the most efficient method for detecting an abnormality in the patient's breast. It is a technique of imaging diagnostic that requires special care because radiographs without adequate quality may lead to a false diagnosis and lead to the need for a repeat examination, increasing the dose of radiation in the patient. This study aimed to evaluate the average glandular dose (AGD), depending on the breast thickness in patients undergoing routine tests, with a digital computer radiography processing system. Analyzed 30 exhibitions in patients aged (65 ± 12) years, in the right and left caudal skull projections, for breasts with thicknesses between 45 mm and 50 mm. The calculated value of the AGD for this track thickness was (1.600 ± 0.009) mGy. The performance of mammography quality control tests was satisfactory and the AGD values obtained for the chosen thickness range is acceptable, since the threshold achievable is 1.6 mGy and the acceptable is 2 mGy. In Brazil, it is only required the input dose calculation in skin for 45 mm breasts. However, the calculation of AGD is required for different thicknesses of the breast, to identify the best mammographic pattern aiming at better image quality at the lowest dose provided the patient

  11. Technical Evaluation of Oak Ridge Filter Test Facility

    CERN Document Server

    Kriskovich, J R

    2002-01-01

    Two evaluations of the Oak Ridge Department of Energy (DOE) Filter Test Facility (FTF) were performed on December 11 and 12, 2001, and consisted of a quality assurance and a technical evaluation. This report documents results of the technical evaluation.

  12. Evaluating low pass filters on SPECT reconstructed cardiac orientation estimation

    Science.gov (United States)

    Dwivedi, Shekhar

    2009-02-01

    Low pass filters can affect the quality of clinical SPECT images by smoothing. Appropriate filter and parameter selection leads to optimum smoothing that leads to a better quantification followed by correct diagnosis and accurate interpretation by the physician. This study aims at evaluating the low pass filters on SPECT reconstruction algorithms. Criteria for evaluating the filters are estimating the SPECT reconstructed cardiac azimuth and elevation angle. Low pass filters studied are butterworth, gaussian, hamming, hanning and parzen. Experiments are conducted using three reconstruction algorithms, FBP (filtered back projection), MLEM (maximum likelihood expectation maximization) and OSEM (ordered subsets expectation maximization), on four gated cardiac patient projections (two patients with stress and rest projections). Each filter is applied with varying cutoff and order for each reconstruction algorithm (only butterworth used for MLEM and OSEM). The azimuth and elevation angles are calculated from the reconstructed volume and the variation observed in the angles with varying filter parameters is reported. Our results demonstrate that behavior of hamming, hanning and parzen filter (used with FBP) with varying cutoff is similar for all the datasets. Butterworth filter (cutoff > 0.4) behaves in a similar fashion for all the datasets using all the algorithms whereas with OSEM for a cutoff < 0.4, it fails to generate cardiac orientation due to oversmoothing, and gives an unstable response with FBP and MLEM. This study on evaluating effect of low pass filter cutoff and order on cardiac orientation using three different reconstruction algorithms provides an interesting insight into optimal selection of filter parameters.

  13. Design and Optimisation of a Simple Filter Group for Reactive Power Distribution

    Directory of Open Access Journals (Sweden)

    Ryszard Klempka

    2016-01-01

    Full Text Available Basic methods are presented to design a simple filter group and a method of shaping the resultant of the filter group’s impedance characteristics (distribution of the characteristics’ extremes and then project equations were transformed into a uniform, common form that addresses issues of the reactive power distribution between component filters. The analysis also takes into account the filters’ detuning from the reduced harmonics and quality factors of passive elements. Another important factor of the analysis considered was the power grid equivalent impedance affecting the filtration effectiveness. A criterion for the filter group’s filtration effectiveness evaluation was proposed and optimisation was completed for the reactive power distribution between separate filters in the function of the power grid’s equivalent inductance.

  14. Dual-energy approach to contrast-enhanced mammography using the balanced filter method: spectral optimization and preliminary phantom measurement.

    Science.gov (United States)

    Saito, Masatoshi

    2007-11-01

    Dual-energy contrast agent-enhanced mammography is a technique of demonstrating breast cancers obscured by a cluttered background resulting from the contrast between soft tissues in the breast. The technique has usually been implemented by exploiting two exposures to different x-ray tube voltages. In this article, another dual-energy approach using the balanced filter method without switching the tube voltages is described. For the spectral optimization of dual-energy mammography using the balanced filters, we applied a theoretical framework reported by Lemacks et al. [Med. Phys. 29, 1739-1751 (2002)] to calculate the signal-to-noise ratio (SNR) in an iodinated contrast agent subtraction image. This permits the selection of beam parameters such as tube voltage and balanced filter material, and the optimization of the latter's thickness with respect to some critical quantity-in this case, mean glandular dose. For an imaging system with a 0.1 mm thick CsI:T1 scintillator, we predict that the optimal tube voltage would be 45 kVp for a tungsten anode using zirconium, iodine, and neodymium balanced filters. A mean glandular dose of 1.0 mGy is required to obtain an SNR of 5 in order to detect 1.0 mg/cm2 iodine in the resulting clutter-free image of a 5 cm thick breast composed of 50% adipose and 50% glandular tissue. In addition to spectral optimization, we carried out phantom measurements to demonstrate the present dual-energy approach for obtaining a clutter-free image, which preferentially shows iodine, of a breast phantom comprising three major components-acrylic spheres, olive oil, and an iodinated contrast agent. The detection of iodine details on the cluttered background originating from the contrast between acrylic spheres and olive oil is analogous to the task of distinguishing contrast agents in a mixture of glandular and adipose tissues.

  15. Dual-energy approach to contrast-enhanced mammography using the balanced filter method: Spectral optimization and preliminary phantom measurement

    International Nuclear Information System (INIS)

    Saito, Masatoshi

    2007-01-01

    Dual-energy contrast agent-enhanced mammography is a technique of demonstrating breast cancers obscured by a cluttered background resulting from the contrast between soft tissues in the breast. The technique has usually been implemented by exploiting two exposures to different x-ray tube voltages. In this article, another dual-energy approach using the balanced filter method without switching the tube voltages is described. For the spectral optimization of dual-energy mammography using the balanced filters, we applied a theoretical framework reported by Lemacks et al. [Med. Phys. 29, 1739-1751 (2002)] to calculate the signal-to-noise ratio (SNR) in an iodinated contrast agent subtraction image. This permits the selection of beam parameters such as tube voltage and balanced filter material, and the optimization of the latter's thickness with respect to some critical quantity--in this case, mean glandular dose. For an imaging system with a 0.1 mm thick CsI:Tl scintillator, we predict that the optimal tube voltage would be 45 kVp for a tungsten anode using zirconium, iodine, and neodymium balanced filters. A mean glandular dose of 1.0 mGy is required to obtain an SNR of 5 in order to detect 1.0 mg/cm 2 iodine in the resulting clutter-free image of a 5 cm thick breast composed of 50% adipose and 50% glandular tissue. In addition to spectral optimization, we carried out phantom measurements to demonstrate the present dual-energy approach for obtaining a clutter-free image, which preferentially shows iodine, of a breast phantom comprising three major components - acrylic spheres, olive oil, and an iodinated contrast agent. The detection of iodine details on the cluttered background originating from the contrast between acrylic spheres and olive oil is analogous to the task of distinguishing contrast agents in a mixture of glandular and adipose tissues

  16. Pipe Wall Thickness Monitoring Using Dry-Coupled Ultrasonic Waveguide Technique

    International Nuclear Information System (INIS)

    Cheong, Yong Moo; Kim, Ha Nam; Kim, Hong Pyo

    2012-01-01

    In order to monitor a corrosion or FAC (Flow Accelerated Corrosion) in a pipe, there is a need to measure pipe wall thickness at high temperature. Ultrasonic thickness gauging is the most commonly used non-destructive testing technique for wall thickness measurement. However, current commonly available ultrasonic transducers cannot withstand high temperatures, such as above 200 .deg. C. It is therefore necessary to carry out manual measurements during plant shutdowns. The current method thus reveals several disadvantages: inspection have to be performed during shutdowns with the possible consequences of prolonging down time and increasing production losses, insulation has to be removed and replaced for each manual measurement, and scaffolding has to be installed to inaccessible areas, resulting in considerable cost for interventions. It has been suggested that a structural health monitoring approach with permanently installed ultrasonic thickness gauges could have substantial benefits over current practices. The main reasons why conventional piezoelectric ultrasonic transducers cannot be used at high temperatures are that the piezo-ceramic becomes depolarized at temperature above the Curie temperature and because differential thermal expansion of the substrate, couplant, and piezoelectric materials cause failure. In this paper, a shear horizontal waveguide technique for wall thickness monitoring at high temperature is investigated. Two different designs for contact to strip waveguide are shown and the quality of output signal is compared and reviewed. After a success of acquiring high quality ultrasonic signal, experiment on the wall thickness monitoring at high temperature is planned

  17. Effect of Coil Current on the Properties of Hydrogenated DLC Coatings Fabricated by Filtered Cathodic Vacuum Arc Technique

    Science.gov (United States)

    Liao, Bin; Ouyang, Xiaoping; Zhang, Xu; Wu, Xianying; Bian, Baoan; Ying, Minju; Jianwu, Liu

    2018-01-01

    We successfully prepared hydrogenated DLC (a-C:H) with a thickness higher than 25 μm on stainless steel using a filtered cathode vacuum arc (FCVA) technique. The structural and mechanical properties of DLC were systematically analyzed using different methods such as x-ray photoelectron spectroscopy, Raman spectroscopy, scanning electron microscopy, Vickers hardness, nanohardness, and friction and wear tests. The effect of coil current on the arc voltage, ion current, and mechanical properties of resultant films was systematically investigated. The novelty of this study is the fabrication of DLC with Vickers hardness higher than 1500 HV, in the meanwhile with the thickness higher than 30 μm through varying the coil current with FCVA technique. The results indicated that the ion current, deposition rate, friction coefficient, and Vickers hardness of DLC were significantly affected by the magnetic field inside the filtered duct.

  18. Exploring an optimal wavelet-based filter for cryo-ET imaging.

    Science.gov (United States)

    Huang, Xinrui; Li, Sha; Gao, Song

    2018-02-07

    Cryo-electron tomography (cryo-ET) is one of the most advanced technologies for the in situ visualization of molecular machines by producing three-dimensional (3D) biological structures. However, cryo-ET imaging has two serious disadvantages-low dose and low image contrast-which result in high-resolution information being obscured by noise and image quality being degraded, and this causes errors in biological interpretation. The purpose of this research is to explore an optimal wavelet denoising technique to reduce noise in cryo-ET images. We perform tests using simulation data and design a filter using the optimum selected wavelet parameters (three-level decomposition, level-1 zeroed out, subband-dependent threshold, a soft-thresholding and spline-based discrete dyadic wavelet transform (DDWT)), which we call a modified wavelet shrinkage filter; this filter is suitable for noisy cryo-ET data. When testing using real cryo-ET experiment data, higher quality images and more accurate measures of a biological structure can be obtained with the modified wavelet shrinkage filter processing compared with conventional processing. Because the proposed method provides an inherent advantage when dealing with cryo-ET images, it can therefore extend the current state-of-the-art technology in assisting all aspects of cryo-ET studies: visualization, reconstruction, structural analysis, and interpretation.

  19. Ensemble Kalman filtering in presence of inequality constraints

    Science.gov (United States)

    van Leeuwen, P. J.

    2009-04-01

    Kalman filtering is presence of constraints is an active area of research. Based on the Gaussian assumption for the probability-density functions, it looks hard to bring in extra constraints in the formalism. On the other hand, in geophysical systems we often encounter constraints related to e.g. the underlying physics or chemistry, which are violated by the Gaussian assumption. For instance, concentrations are always non-negative, model layers have non-negative thickness, and sea-ice concentration is between 0 and 1. Several methods to bring inequality constraints into the Kalman-filter formalism have been proposed. One of them is probability density function (pdf) truncation, in which the Gaussian mass from the non-allowed part of the variables is just equally distributed over the pdf where the variables are alolwed, as proposed by Shimada et al. 1998. However, a problem with this method is that the probability that e.g. the sea-ice concentration is zero, is zero! The new method proposed here does not have this drawback. It assumes that the probability-density function is a truncated Gaussian, but the truncated mass is not distributed equally over all allowed values of the variables, but put into a delta distribution at the truncation point. This delta distribution can easily be handled with in Bayes theorem, leading to posterior probability density functions that are also truncated Gaussians with delta distributions at the truncation location. In this way a much better representation of the system is obtained, while still keeping most of the benefits of the Kalman-filter formalism. In the full Kalman filter the formalism is prohibitively expensive in large-scale systems, but efficient implementation is possible in ensemble variants of the kalman filter. Applications to low-dimensional systems and large-scale systems will be discussed.

  20. Report on the quality control study NAT-7 for the determination of trace and minor elements in dust artificially loaded on air filters

    International Nuclear Information System (INIS)

    Bleise, A.; Smodis, A.

    2002-02-01

    A quality control study was organized on two air filters artificially loaded with urban dust. One dust material was collected from the air intake ducts of the Vienna General Hospital, the second material was collected from the main ventilation shaft of a road tunnel in Prague. 49 laboratories from 40 countries participated in the study, providing 53 sets of results. The following analytical methods were used: neutron activation analysis (NAA), inductive coupled plasma atomic emission spectrometry (ICP-AES), inductively coupled plasma mass spectrometry (ICP-MS), particle induced X-ray emission spectrometry (PDCE), atomic absorption spectrometry (AAS), and X-ray fluorescence spectrometry (XRF). The results were evaluated following the standard LEA procedures for (1) an interlaboratory comparison exercise and (2) a proficiency test using established target values. For the air filter sample V, 754 laboratory mean values for 38 elements were reported. More than 4 mean values were obtained for 26 measurands and these were statistically evaluated. Only 10 % 71 values) of the results were detected as outliers by the statistical data evaluation. The results and statistical parameters are listed in the appendices I and II. The results were also evaluated as a proficiency test using established target values. Precision and accuracy criteria were applied to 15 elements. 534 laboratory mean values were reported for those elements, 114 values (20%) did not pass the set proficiency test criteria. The individual laboratory results are listed in appendix IV. For the air filter sample P, 694 laboratory mean values for 38 elements were reported. More than 4 mean values were obtained for 26 measurands and these were statistically evaluated. Only 9% (60 values) of the results were detected as outliers by the statistical data evaluation. The results and statistical parameters are listed in the appendices I and II. The results were also evaluated as a proficiency test using target values

  1. An Efficient FPGA Implementation of Optimized Anisotropic Diffusion Filtering of Images

    Directory of Open Access Journals (Sweden)

    Chandrajit Pal

    2016-01-01

    Full Text Available Digital image processing is an exciting area of research with a variety of applications including medical, surveillance security systems, defence, and space applications. Noise removal as a preprocessing step helps to improve the performance of the signal processing algorithms, thereby enhancing image quality. Anisotropic diffusion filtering proposed by Perona and Malik can be used as an edge-preserving smoother, removing high-frequency components of images without blurring their edges. In this paper, we present the FPGA implementation of an edge-preserving anisotropic diffusion filter for digital images. The designed architecture completely replaced the convolution operation and implemented the same using simple arithmetic subtraction of the neighboring intensities within a kernel, preceded by multiple operations in parallel within the kernel. To improve the image reconstruction quality, the diffusion coefficient parameter, responsible for controlling the filtering process, has been properly analyzed. Its signal behavior has been studied by subsequently scaling and differentiating the signal. The hardware implementation of the proposed design shows better performance in terms of reconstruction quality and accelerated performance with respect to its software implementation. It also reduces computation, power consumption, and resource utilization with respect to other related works.

  2. Granular filters for water treatment: heterogeneity and diagnostic tools

    DEFF Research Database (Denmark)

    Lopato, Laure Rose

    the last barrier against disinfection resistant protozoan pathogens and this has led to increased regulation of the filtration process. To be able to produce high-quality filtrate in a constant and reliable manner while meeting stricter drinking water guideline values, it is important to be able......Rapid granular filters are the most commonly used filters in drinking water treatment plants and are the focus of this PhD study. They are usually constructed with sand, anthracite, activated carbon, garnet sand, and ilmenite and have filtration rates ranging from 3 to 15 m/h. Filters are often...... options prescribed. The diagnostic tools are then used again to verify the efficiency of the solution applied. If the problem is not solved the whole process starts again. These tools are of significant interest for the development of the Water Safety Plans recommended by WHO to monitor filters...

  3. Spin-filtering effect and proximity effect in normal metal/ferromagnetic insulator/normal metal/superconductor junctions

    International Nuclear Information System (INIS)

    Li Hong; Yang Wei; Yang Xinjian; Qin Minghui; Xu Yihong

    2007-01-01

    Taking into account the thickness of the ferromagnetic insulator (FI), the spin-filtering effect and proximity effect in normal metal/ferromagnetic insulator/normal metal/superconductor (NM/FI/NM/SC) junctions are studied based on an extended Blonder-Tinkham-Klapwijk (BTK) theory. It is shown that a spin-dependent energy shift during the tunneling process induces splitting of the sub-energy gap conductance peaks and the spin polarization in the ferromagnetic insulator causes an imbalance of the peak heights. Different from the ferromagnet the spin-filtering effect of the FI cannot cause the reversion of the normalized conductance in NM/FI/NM/SC junctions

  4. Determination of the electronic temperature in the torsatron TJ-I Upgrade by the two filters

    Energy Technology Data Exchange (ETDEWEB)

    Medina, F.; Ochando, M.

    1994-07-01

    A Te monitor for the TJ-IU torsatron, based on the two-filters method, has been designed. It will consist of two surface-barrier silicon detectors looking at the same plasma region through berylium filters of different thickness. Plasma electron temperature is deduced from the ratio of the soft-x-ray fluxes transmitted through the two filters. The flexibility in magnetic configuration of TJ-IU plasmas has been taken into account in the mechanical design of this diagnostic. It will be attached to an upper 1 port of the vacuum vessel and the whole system will be movable both, to change the spatial resolution when needed and to enable the scan of the full plasma cross-section to obtain the radial profile of electron temperature in a shot-to-shot basis. (Author) 7 refs.

  5. Determination of the electronic temperature in the torsatron TJ-I Upgrade by the two filters

    International Nuclear Information System (INIS)

    Medina, F.; Ochando, M.

    1994-01-01

    A Te monitor for the TJ-IU torsatron, based on the two-filters method, has been designed. It will consist of two surface-barrier silicon detectors looking at the same plasma region through berylium filters of different thickness. Plasma electron temperature is deduced from the ratio of the soft-x-ray fluxes transmitted through the two filters. The flexibility in magnetic configuration of TJ-IU plasmas has been taken into account in the mechanical design of this diagnostic. It will be attached to an upper 1 port of the vacuum vessel and the whole system will be movable both, to change the spatial resolution when needed and to enable the scan of the full plasma cross-section to obtain the radial profile of electron temperature in a shot-to-shot basis. (Author) 7 refs

  6. Determination of the electronic temperature in the torsatron TJ-I Upgrade by the two filters

    International Nuclear Information System (INIS)

    Medina, F.; Ochando, M.

    1994-01-01

    A Te monitor for the TJ-IU torsatron, based on the two-filters method, has been designed. It will consist of two surface-barrier silicon detectors looking at the same plasma region through berilium filters of different thickness. Plasma electron temperature is deduced from the ratio of the soft-x-ray fluxes transmitted through the two filters. The flexibility in magnetic configuration of TJ-IU plasmas has been taken into account in the mechanical design of this diagnostic. It will be attached to an upper port of the vacuum vessel and the whole system will be movable both, to change the spatial resolution when needed and to enable the scan of the full plasma cross-section to obtain the radial profile of electron temperature in a shot-to-shot basis. (Author)

  7. DEVELOPMENT OF AG-1 SECTION FI ON METAL MEDIA FILTERS - 9061

    International Nuclear Information System (INIS)

    Adamson, D.; Waggoner, C.A.

    2008-01-01

    Development of a metal media standard (FI) for ASME AG-1 (Code on Nuclear Air and Gas Treatment) has been under way for almost ten years. This paper will provide a brief history of the development process of this section and a detailed overview of its current content/status. There have been at least two points when dramatic changes have been made in the scope of the document due to feedback from the full Committee on Nuclear Air and Gas Treatment (CONAGT). Development of the proposed section has required resolving several difficult issues associated with scope; namely, filtering efficiency, operating conditions (media velocity, pressure drop, etc.), qualification testing, and quality control/acceptance testing. A proposed version of Section FI is currently undergoing final revisions prior to being submitted for balloting. The section covers metal media filters of filtering efficiencies ranging from medium (less than 99.97%) to high (99.97% and greater). Two different types of high efficiency filters are addressed; those units intended to be a direct replacement of Section FC fibrous glass HEPA filters and those that will be placed into newly designed systems capable of supporting greater static pressures and differential pressures across the filter elements. Direct replacements of FC HEPA filters in existing systems will be required to meet equivalent qualification and testing requirements to those contained in Section FC. A series of qualification and quality assurance test methods have been identified for the range of filtering efficiencies covered by this proposed standard. Performance characteristics of sintered metal powder vs. sintered metal fiber media are dramatically different with respect to parameters like differential pressures and rigidity of the media. Wide latitude will be allowed for owner specification of performance criteria for filtration units that will be placed into newly designed systems. Such allowances will permit use of the most

  8. Kinetics of the crust thickness development of bread during baking.

    Science.gov (United States)

    Soleimani Pour-Damanab, Alireza; Jafary, A; Rafiee, Sh

    2014-11-01

    The development of crust thickness of bread during baking is an important aspect of bread quality and shelf-life. Computer vision system was used for measuring the crust thickness via colorimetric properties of bread surface during baking process. Crust thickness had a negative and positive relationship with Lightness (L (*) ) and total color change (E (*) ) of bread surface, respectively. A linear negative trend was found between crust thickness and moisture ratio of bread samples. A simple mathematical model was proposed to predict the development of crust thickness of bread during baking, where the crust thickness was depended on moisture ratio that was described by the Page moisture losing model. The independent variables of the model were baking conditions, i.e. oven temperature and air velocity, and baking time. Consequently, the proposed model had well prediction ability, as the mean absolute estimation error of the model was 7.93 %.

  9. Impact of HVAC filter on indoor air quality in terms of ozone removal and carbonyls generation

    Science.gov (United States)

    Lin, Chi-Chi; Chen, Hsuan-Yu

    2014-06-01

    This study aims at detecting ozone removal rates and corresponding carbonyls generated by ozone reaction with HVAC filters from various building, i.e., shopping mall, school, and office building. Studies were conducted in a small-scale environmental chamber. By examining dust properties including organic carbon proportion and specific surface area of dusts adsorbed on filters along with ozone removal rates and carbonyls generation rate, the relationship among dust properties, ozone removal rates, and carbonyls generation was identified. The results indicate a well-defined positive correlation between ozone removal efficiency and carbonyls generation on filters, as well as a positive correlation among the mass of organic carbon on filters, ozone removal efficiency and carbonyls generations.

  10. High Efficiency, Transparent, Reusable, and Active PM2.5 Filters by Hierarchical Ag Nanowire Percolation Network.

    Science.gov (United States)

    Jeong, Seongmin; Cho, Hyunmin; Han, Seonggeun; Won, Phillip; Lee, Habeom; Hong, Sukjoon; Yeo, Junyeob; Kwon, Jinhyeong; Ko, Seung Hwan

    2017-07-12

    Air quality has become a major public health issue in Asia including China, Korea, and India. Particulate matters are the major concern in air quality. We present the first environmental application demonstration of Ag nanowire percolation network for a novel, electrical type transparent, reusable, and active PM2.5 air filter although the Ag nanowire percolation network has been studied as a very promising transparent conductor in optoelectronics. Compared with previous particulate matter air filter study using relatively weaker short-range intermolecular force in polar polymeric nanofiber, Ag nanowire percolation network filters use stronger long-range electrostatic force to capture PM2.5, and they are highly efficient (>99.99%), transparent, working on an active mode, low power consumption, antibacterial, and reusable after simple washing. The proposed new particulate matter filter can be applied for a highly efficient, reusable, active and energy efficient filter for wearable electronics application.

  11. AN APPLE GRADING SYSTEM ACCORDING TO EUROPEAN FRUIT QUALITY STANDARDS USING GABOR FILTER AND ARTIFICIAL NEURAL NETWORKS

    Directory of Open Access Journals (Sweden)

    KEYVAN ASEFPOUR VAKILIAN

    2016-04-01

    Full Text Available With the advent of applications of machine learning methods in food engineering in recent decades, several intelligent methods have been introduced in fruit grading technology. In this study, an apple grading system is presented using image’s textural features extraction and artificial intelligence. The objective of this study was to simplify the use of Gabor filter in classification of two varieties of apple fruits (Golden Delicious and Red Delicious in four categories according to the European fruit quality standards. Using this filter, neural network classifier was trained for four category grading of the fruits. Two textural parameters were extracted from each obtained image: mean and variance of energy values of obtained image representing image’s luminous intensity and contrast, respectively. Experimental results indicated that the training of extracted features of about 350 fruits enabled the network to classify the test samples with appropriate accuracy. Compared to the state-of-the-art, the proposed grading categories (‘Extra’, ‘Type 1’, ‘Type 2’ and ‘Rejected’ classes achieved acceptable recognition rates of about 89 % and 92 % overall accuracy for Golden Delicious and Red Delicious varieties, respectively. These experimental results show the appropriate application of proposed method in fast grading of apple fruits. Furthermore, proposed feature extraction and network training methods can be used efficiently in online applications.

  12. Improving inferior vena cava filter retrieval rates with the define, measure, analyze, improve, control methodology.

    Science.gov (United States)

    Sutphin, Patrick D; Reis, Stephen P; McKune, Angie; Ravanzo, Maria; Kalva, Sanjeeva P; Pillai, Anil K

    2015-04-01

    To design a sustainable process to improve optional inferior vena cava (IVC) filter retrieval rates based on the Define, Measure, Analyze, Improve, Control (DMAIC) methodology of the Six Sigma process improvement paradigm. DMAIC, an acronym for Define, Measure, Analyze, Improve, and Control, was employed to design and implement a quality improvement project to increase IVC filter retrieval rates at a tertiary academic hospital. Retrievable IVC filters were placed in 139 patients over a 2-year period. The baseline IVC filter retrieval rate (n = 51) was reviewed through a retrospective analysis, and two strategies were devised to improve the filter retrieval rate: (a) mailing of letters to clinicians and patients for patients who had filters placed within 8 months of implementation of the project (n = 43) and (b) a prospective automated scheduling of a clinic visit at 4 weeks after filter placement for all new patients (n = 45). The effectiveness of these strategies was assessed by measuring the filter retrieval rates and estimated increase in revenue to interventional radiology. IVC filter retrieval rates increased from a baseline of 8% to 40% with the mailing of letters and to 52% with the automated scheduling of a clinic visit 4 weeks after IVC filter placement. The estimated revenue per 100 IVC filters placed increased from $2,249 to $10,518 with the mailing of letters and to $17,022 with the automated scheduling of a clinic visit. Using the DMAIC methodology, a simple and sustainable quality improvement intervention was devised that markedly improved IVC filter retrieval rates in eligible patients. Copyright © 2015 SIR. Published by Elsevier Inc. All rights reserved.

  13. Analytic expression for the giant fieldlike spin torque in spin-filter magnetic tunnel junctions

    Science.gov (United States)

    Tang, Y.-H.; Huang, Z.-W.; Huang, B.-H.

    2017-08-01

    We propose analytic expressions for fieldlike, T⊥, and spin-transfer, T∥, spin torque components in the spin-filter-based magnetic tunnel junction (SFMTJ), by using the single-band tight-binding model with the nonequilibrium Keldysh formalism. In consideration of multireflection processes between noncollinear magnetization of the spin-filter (SF) barrier and the ferromagnetic (FM) electrode, the central spin-selective SF barrier plays an active role in the striking discovery T⊥≫T∥ , which can be further identified by the unusual barrier thickness dependence of giant T⊥. Our general expressions reveal the sinusoidal angular dependence of both spin torque components, even in the presence of the SF barrier.

  14. Voltage Harmonics Mitigation through Hybrid Active Power Filter

    Directory of Open Access Journals (Sweden)

    Anwer Ali Sahito

    2016-01-01

    Full Text Available Fast dynamic response, high efficiency, low cost and small size of power electronic converters have exponentially increased their use in modern power system which resulted in harmonically distorted voltage and currents. Voltage harmonics mainly caused by current harmonics are more dangerous as performance and expected operating life of other power system equipment are affected by harmonically distorted supply voltage. Electronic filter circuits are used to improve system power quality by mitigating adverse effects of harmonics. Hybrid filters having advantages of both passive and active filters are preferred to resolve the problem of harmonics efficiently and avoiding any chance of resonance. In this paper, a three phase three wire network is considered to supply an adjustable speed drive represented by a resistive load connected across a three phase bridge rectifier. Simulation of the considered system shows THD (Total Harmonic Distortion of 18.91 and 7.61% in supply current and voltage respectively. A HAPF (Hybrid Active Power Filter is proposed to reduce these THD values below 5% as recommended by IEEE Standard-519. P-Q theorem is used to calculate required parameters for proposed filter, which is implemented through hysteresis control. Simulation results confirm the effectiveness of the designed filter as THD for both current and voltage have reduced below allowable limit of 5%.

  15. Band-gap tunable dielectric elastomer filter for low frequency noise

    Science.gov (United States)

    Jia, Kun; Wang, Mian; Lu, Tongqing; Zhang, Jinhua; Wang, Tiejun

    2016-05-01

    In the last decades, diverse materials and technologies for sound insulation have been widely applied in engineering. However, suppressing the noise radiation at low frequency still remains a challenge. In this work, a novel membrane-type smart filter, consisting of a pre-stretched dielectric elastomer membrane with two compliant electrodes coated on the both sides, is presented to control the low frequency noise. Since the stiffness of membrane dominates its acoustic properties, sound transmission band-gap of the membrane filter can be tuned by adjusting the voltage applied to the membrane. The impedance tube experiments have been carried out to measure the sound transmission loss (STL) of the filters with different electrodes, membrane thickness and pre-stretch conditions. The experimental results show that the center frequency of sound transmission band-gap mainly depends on the stress in the dielectric elastomer, and a large band-gap shift (more than 60 Hz) can be achieved by tuning the voltage applied to the 85 mm diameter VHB4910 specimen with pre-stretch {λ }0=3. Based on the experimental results and the assumption that applied electric field is independent of the membrane behavior, 3D finite element analysis has also been conducted to calculate the membrane stress variation. The sound filter proposed herein may provide a promising facility to control low frequency noise source with tonal characteristics.

  16. Full reflector thickness and isolation thickness on neutron transport

    International Nuclear Information System (INIS)

    Sakai, Tomohiro; Naito, Yoshitaka; Komuro, Yuichi.

    1988-08-01

    A method to determine ''full reflector thickness'' and ''isolation thickness'', which is utilized for criticality safety evaluation on nuclear fuel facilities, was proposed in this paper. Firstly, a calculation was tryed to obtain the two kinds of thicknesses from the result of criticality calculations for a specific case. Then, two simple equations which calculates the two kinds of thicknesses were made from the relation between reflector (or isolator) thickness and k eff , and one-group diffusion theory. Finally, we proposed a new method to determine the thicknesses. From the method we proposed, ''full reflector thickness'' and ''isolation thickness'' can be obtain using the equations and migration length of the reflector (or isolator) and infinite and effective multiplication factor of the fuel. (author)

  17. Filtering and concentrating device for processing radioactive waste and operation method therefor, processing facility for radioactive wastes and processing method therefor

    International Nuclear Information System (INIS)

    Serizawa, Ken-ichi; Yamazaki, Masami

    1998-01-01

    A filtering and concentrating device is prepared by assembling a porous ceramic filtering material having a pore diameter of 1 μm or less secured by a support to a filtering device main body. The porous ceramic filtering material preferably comprises a surface portion having pores having a diameter of 1 μm or less and a hollow ceramic material having filtering flow channels having a diameter greater than the pores on the surface portion. The ratio of the diameter and the thickness of the hollow ceramic material is determined to greater than 50 : 1. The filtering and concentrating device precisely filter and concentrate radioactive liquid wastes containing an insoluble solid content generated from a nuclear power plant to conduct solid/liquid separation thereby forming a filtrate and concentrated wastes having a mass concentration of 20% or more. With such a constitution, stable filtration and concentration can be conducted while reducing occurrence of clogging of filtering materials. In addition, the frequency for the exchange of filtering materials can be reduced. (I.N.)

  18. Calculation of characteristics of X-ray devices

    Directory of Open Access Journals (Sweden)

    Orobinskyi A. N.

    2015-12-01

    Full Text Available Actuality of this work is related to human radiation safety during tuning and regulation of X-ray devices in the process of their development and production. The more precise the calculations for the device are, the less time is required for its tuning and regulation, and thus people are less exposed to radiation. When developing an X-ray device, it is necessary to choose an X-ray tube and filters taking into account the application domain of the device. In order to do this, one should know anode voltage, X-ray tube anode current, material and thickness of filters, i.e. to calculate these characteristics at the set quality of X-ray radiation. The known published studies do not give any solution to this problem. The scientific novelty of this work is that it establishes the interdependence between main characteristics of the X-ray device: the function of the device defines the quality of X-ray radiation (mean photon energy and air kerma power; mean photon energy depends on the X-ray anode tube voltage and spectral resolution; air kerma power depends on anode tube voltage, current of X-ray tube anode, spectral resolution, thicknesses of the filters and their materials; spectral resolution depends on thicknesses of filters and their materials; thickness of filters depends on the material of the filter (the linear coefficient of weakening of X-ray radiation. Knowledge of interdependence of basic characteristics of the X-ray devices allowes developing simple algorithm for their calculation at the values of homogeneity coefficient from 0,8 to 1, which makes it possible to choose an X-ray tube and filters with the purpose of obtaining X-ray radiation of the set quality.

  19. A Tunable Low Noise Active Bandpass Filter Using a Noise Canceling Technique

    Directory of Open Access Journals (Sweden)

    N. Soltani

    2016-12-01

    Full Text Available A monolithic tunable low noise active bandpass filter is presented in this study. Biasing voltages can control the center frequency and quality factor. By keeping the gain constant, the center frequency shift is 300 MHz. The quality factor can range from 90 to 290 at the center frequency. By using a noise cancelling circuit, noise is kept lower than 2.8 dB. The proposed filter is designed using MMIC technology with a center frequency of 2.4 GHz and a power consumption of 180 mW. ED02AH technology is used to simulate the circuit elements.

  20. Controlling flow conditions of test filters in iodine filters

    International Nuclear Information System (INIS)

    Holmberg, R.; Laine, J.

    1979-03-01

    Several different iodine filter and test filter designs and experience gained from their operation are presented. For the flow experiments, an iodine filter system equipped with flow regulating and measuring devices was built. In the experiments the influence of the packing method of the iodine sorption material and the influence of the flow regulating and measuring divices upon the flow conditions in the test filters was studied. On the basis of the experiments it has been shown that the flows through the test filters always can be adjusted to a correct value if there only is a high enough pressure difference available across the test filter ducting. As a result of the research, several different methods are presented with which the flows through the test filters in both operating and future iodine sorption system can easily be measured and adjusted to their correct values. (author)

  1. Image quality enhancement for skin cancer optical diagnostics

    Science.gov (United States)

    Bliznuks, Dmitrijs; Kuzmina, Ilona; Bolocko, Katrina; Lihachev, Alexey

    2017-12-01

    The research presents image quality analysis and enhancement proposals in biophotonic area. The sources of image problems are reviewed and analyzed. The problems with most impact in biophotonic area are analyzed in terms of specific biophotonic task - skin cancer diagnostics. The results point out that main problem for skin cancer analysis is the skin illumination problems. Since it is often not possible to prevent illumination problems, the paper proposes image post processing algorithm - low frequency filtering. Practical results show diagnostic results improvement after using proposed filter. Along that, filter do not reduces diagnostic results' quality for images without illumination defects. Current filtering algorithm requires empirical tuning of filter parameters. Further work needed to test the algorithm in other biophotonic applications and propose automatic filter parameter selection.

  2. DIGITAL FILTERS IMPLEMENTATION IN MICROPROCESSOR-BASED RELAY PROTECTION

    Directory of Open Access Journals (Sweden)

    Yu. V. Rumiantsev

    2016-01-01

    Full Text Available This article presents the implementation of digital filters used in digital relay protection current measuring elements. Mathematical descriptions of the considered digital filters as well as the computer programs for their coefficients calculation are described. It has been shown that in order to reliable estimate the digital filter performance its input signals waveforms must be close to the actual secondary current waveform of the current transformer to which the digital protection with the estimated digital filter is connected. For these purposes in MatLab–Simulink dynamic simulation environment the power system and the current measuring element models were developed. Performed calculations allowed to reveal that the exponentially decaying DC component which in some cases contains in primary fault current drives the current transformer core into saturation even when its nominal parameters are not exceeded. This results in distortion of the current transformer secondary current which in this case contains higher and inter-harmonics. Moreover, such harmonic content is not completely taking into account during coefficients calculation of the considered digital filters what results in signal magnitude estimation inaccuracy. Comparison of the digital filters response to the above-mentioned input signals allowed to find out such digital filter implementations which enable signal magnitude estimation with a minimum error. Ways of filtering quality improvement concerned with the window functions are proposed. Thus, the joint usage of digital filter and Hamming window allows to achieve the zero value of the signal magnitude gain factor in high-frequency range and substantially suppress all spectral components above 100 Hz. The increasing of the signal magnitude settling time in this case can be reduced by choosing the most optimal parameters of the all components of the current measuring element.

  3. The Rao-Blackwellized Particle Filter: A Filter Bank Implementation

    Directory of Open Access Journals (Sweden)

    Karlsson Rickard

    2010-01-01

    Full Text Available For computational efficiency, it is important to utilize model structure in particle filtering. One of the most important cases occurs when there exists a linear Gaussian substructure, which can be efficiently handled by Kalman filters. This is the standard formulation of the Rao-Blackwellized particle filter (RBPF. This contribution suggests an alternative formulation of this well-known result that facilitates reuse of standard filtering components and which is also suitable for object-oriented programming. Our RBPF formulation can be seen as a Kalman filter bank with stochastic branching and pruning.

  4. Wide Bandpass and Narrow Bandstop Microstrip Filters based on Hilbert fractal geometry: design and simulation results.

    Directory of Open Access Journals (Sweden)

    Yaqeen S Mezaal

    Full Text Available This paper presents new Wide Bandpass Filter (WBPF and Narrow Bandstop Filter (NBSF incorporating two microstrip resonators, each resonator is based on 2nd iteration of Hilbert fractal geometry. The type of filter as pass or reject band has been adjusted by coupling gap parameter (d between Hilbert resonators using a substrate with a dielectric constant of 10.8 and a thickness of 1.27 mm. Numerical simulation results as well as a parametric study of d parameter on filter type and frequency responses are presented and studied. WBPF has designed at resonant frequencies of 2 and 2.2 GHz with a bandwidth of 0.52 GHz, -28 dB return loss and -0.125 dB insertion loss while NBSF has designed for electrical specifications of 2.37 GHz center frequency, 20 MHz rejection bandwidth, -0.1873 dB return loss and 13.746 dB insertion loss. The proposed technique offers a new alternative to construct low-cost high-performance filter devices, suitable for a wide range of wireless communication systems.

  5. SART-Type Half-Threshold Filtering Approach for CT Reconstruction.

    Science.gov (United States)

    Yu, Hengyong; Wang, Ge

    2014-01-01

    The [Formula: see text] regularization problem has been widely used to solve the sparsity constrained problems. To enhance the sparsity constraint for better imaging performance, a promising direction is to use the [Formula: see text] norm (0 < p < 1) and solve the [Formula: see text] minimization problem. Very recently, Xu et al. developed an analytic solution for the [Formula: see text] regularization via an iterative thresholding operation, which is also referred to as half-threshold filtering. In this paper, we design a simultaneous algebraic reconstruction technique (SART)-type half-threshold filtering framework to solve the computed tomography (CT) reconstruction problem. In the medical imaging filed, the discrete gradient transform (DGT) is widely used to define the sparsity. However, the DGT is noninvertible and it cannot be applied to half-threshold filtering for CT reconstruction. To demonstrate the utility of the proposed SART-type half-threshold filtering framework, an emphasis of this paper is to construct a pseudoinverse transforms for DGT. The proposed algorithms are evaluated with numerical and physical phantom data sets. Our results show that the SART-type half-threshold filtering algorithms have great potential to improve the reconstructed image quality from few and noisy projections. They are complementary to the counterparts of the state-of-the-art soft-threshold filtering and hard-threshold filtering.

  6. Convergent Filter Bases

    Directory of Open Access Journals (Sweden)

    Coghetto Roland

    2015-09-01

    Full Text Available We are inspired by the work of Henri Cartan [16], Bourbaki [10] (TG. I Filtres and Claude Wagschal [34]. We define the base of filter, image filter, convergent filter bases, limit filter and the filter base of tails (fr: filtre des sections.

  7. The filtering of raw water with partition system in pool row water for the process

    International Nuclear Information System (INIS)

    Harahap, Sentot Alibasya; Djunaidi

    2003-01-01

    The purpose of filtering raw water in the pool is decreasing soluble dirty in the water from Puspiptek PAM also the dirty from the environments. The monitoring of raw water since 1998 that the raw water is not so good in the quality. This partition system use tree type of screen a.i. the opened 10 mm, Mesh 60 and Mesh 100. The down position use a plat with 400 mm higher from the floor of the pool that given support frame from the L profile and strip plate by stainless steel (SS-304), use for deposited the impurities. The filter capability from the monitoring that the filtering result is a good quality, the TDS drop (Total Dissolved Solvent) is 2,5 gram/liter and the water filtering static type is (4 - 8,5) gram/liter

  8. Improvement of QR Code Recognition Based on Pillbox Filter Analysis

    Directory of Open Access Journals (Sweden)

    Jia-Shing Sheu

    2013-04-01

    Full Text Available The objective of this paper is to perform the innovation design for improving the recognition of a captured QR code image with blur through the Pillbox filter analysis. QR code images can be captured by digital video cameras. Many factors contribute to QR code decoding failure, such as the low quality of the image. Focus is an important factor that affects the quality of the image. This study discusses the out-of-focus QR code image and aims to improve the recognition of the contents in the QR code image. Many studies have used the pillbox filter (circular averaging filter method to simulate an out-of-focus image. This method is also used in this investigation to improve the recognition of a captured QR code image. A blurred QR code image is separated into nine levels. In the experiment, four different quantitative approaches are used to reconstruct and decode an out-of-focus QR code image. These nine reconstructed QR code images using methods are then compared. The final experimental results indicate improvements in identification.

  9. In-situ biogas sparging enhances the performance of an anaerobic membrane bioreactor (AnMBR) with mesh filter in low-strength wastewater treatment.

    Science.gov (United States)

    Li, Na; Hu, Yi; Lu, Yong-Ze; Zeng, Raymond J; Sheng, Guo-Ping

    2016-07-01

    In the recent years, anaerobic membrane bioreactor (AnMBR) technology is being considered as a very attractive alternative for wastewater treatment due to the striking advantages such as upgraded effluent quality. However, fouling control is still a problem for the application of AnMBR. This study investigated the performance of an AnMBR using mesh filter as support material to treat low-strength wastewater via in-situ biogas sparging. It was found that mesh AnMBR exhibited high and stable chemical oxygen demand (COD) removal efficiencies with values of 95 ± 5 % and an average methane yield of 0.24 L CH4/g CODremoved. Variation of transmembrane pressure (TMP) during operation indicated that mesh fouling was mitigated by in-situ biogas sparging and the fouling rate was comparable to that of aerobic membrane bioreactor with mesh filter reported in previous researches. The fouling layer formed on the mesh exhibited non-uniform structure; the porosity became larger from bottom layer to top layer. Biogas sparging could not change the composition but make thinner thickness of cake layer, which might be benefit for reducing membrane fouling rate. It was also found that ultrasonic cleaning of fouled mesh was able to remove most foulants on the surface or pores. This study demonstrated that in-situ biogas sparging enhanced the performance of AnMBRs with mesh filter in low-strength wastewater treatment. Apparently, AnMBRs with mesh filter can be used as a promising and sustainable technology for wastewater treatment.

  10. Potential of simple filters to improve microbial quality of irrigation water used in urban vegetable farming in Ghana

    DEFF Research Database (Denmark)

    Keraita, Bernard; Drechsel, Pay; Konradsen, Flemming

    2008-01-01

    . As part of a larger study on possible interventions for health risk reduction, the potential of simple interventions was explored. Column slow sand filters with three levels of sand depths (0.5 m, 0.75 m and 1 m) and fabric filters made of nylon, cotton and netting were assessed. More than 600 water...... samples were analyzed for helminth eggs and thermotolerant coliforms. Flow rates were also measured. From slow sand filters, 71-96% of helminths and 2 log units (from 7 to 5 log units) of thermotolerant coliforms were removed. Sand depths had no significant influence in the removal. Lower removal rates...... were achieved by fabric filters, with an average removal of 12-62% for helminth eggs and 1 log unit for thermotolerant coliforms. Nylon filters had higher removal rates especially for helminth eggs (58%). Average flow rates for sand filters were 3 m per day and fabric filters had steady flows of about...

  11. Apodized RFI filtering of synthetic aperture radar images

    Energy Technology Data Exchange (ETDEWEB)

    Doerry, Armin Walter

    2014-02-01

    Fine resolution Synthetic Aperture Radar (SAR) systems necessarily require wide bandwidths that often overlap spectrum utilized by other wireless services. These other emitters pose a source of Radio Frequency Interference (RFI) to the SAR echo signals that degrades SAR image quality. Filtering, or excising, the offending spectral contaminants will mitigate the interference, but at a cost of often degrading the SAR image in other ways, notably by raising offensive sidelobe levels. This report proposes borrowing an idea from nonlinear sidelobe apodization techniques to suppress interference without the attendant increase in sidelobe levels. The simple post-processing technique is termed Apodized RFI Filtering (ARF).

  12. Application of DFT Filter Banks and Cosine Modulated Filter Banks in Filtering

    Science.gov (United States)

    Lin, Yuan-Pei; Vaidyanathan, P. P.

    1994-01-01

    None given. This is a proposal for a paper to be presented at APCCAS '94 in Taipei, Taiwan. (From outline): This work is organized as follows: Sec. II is devoted to the construction of the new 2m channel under-decimated DFT filter bank. Implementation and complexity of this DFT filter bank are discussed therein. IN a similar manner, the new 2m channel cosine modulated filter bank is discussed in Sec. III. Design examples are given in Sec. IV.

  13. Assessment of Mean Glandular Dose in Mammography System with Different Anode-Filter Combinations Using MCNP Code.

    Science.gov (United States)

    Gholamkar, Lida; Mowlavi, Ali Asghar; Sadeghi, Mahdi; Athari, Mitra

    2016-10-01

    X-ray mammography is one of the general methods for early detection of breast cancer. Since glandular tissue in the breast is sensitive to radiation and it increases the risk of cancer, the given dose to the patient is very important in mammography. The aim of this study was to determine the average absorbed dose of X-ray radiation in the glandular tissue of the breast during mammography examinations as well as investigating factors that influence the mean glandular dose (MGD). One of the precise methods for determination of MGD absorbed by the breast is Monte Carlo simulation method which is widely used to assess the dose. We studied some different X-ray sources and exposure factors that affect the MGD. "Midi-future" digital mammography system with amorphous-selenium detector was simulated using the Monte Carlo N-particle extended (MCNPX) code. Different anode/filter combinations such as tungsten/silver (W/Ag), tungsten/rhodium (W/Rh), and rhodium/aluminium (Rh/Al) were simulated in this study. The voltage of X-ray tube ranged from 24 kV to 32 kV with 2 kV intervals and the breast phantom thickness ranged from 3 to 8 cm, and glandular fraction g varied from 10% to 100%. MGD was measured for different anode/filter combinations and the effects of changing tube voltage, phantom thickness, combination and glandular breast tissue on MGD were studied. As glandular g and X-ray tube voltage increased, the breast dose increased too, and the increase of breast phantom thickness led to the decrease of MGD. The obtained results for MGD were consistent with the result of Boone et al. that was previously reported. By comparing the results, we saw that W/Rh anode/filter combination is the best choice in breast mammography imaging because of the lowest delivered dose in comparison with W/Ag and Rh/Al. Moreover, breast thickness and g value have significant effects on MGD.

  14. [Restoration filtering based on projection power spectrum for single-photon emission computed tomography].

    Science.gov (United States)

    Kubo, N

    1995-04-01

    To improve the quality of single-photon emission computed tomographic (SPECT) images, a restoration filter has been developed. This filter was designed according to practical "least squares filter" theory. It is necessary to know the object power spectrum and the noise power spectrum. The power spectrum is estimated from the power spectrum of a projection, when the high-frequency power spectrum of a projection is adequately approximated as a polynomial exponential expression. A study of the restoration with the filter based on a projection power spectrum was conducted, and compared with that of the "Butterworth" filtering method (cut-off frequency of 0.15 cycles/pixel), and "Wiener" filtering (signal-to-noise power spectrum ratio was a constant). Normalized mean-squared errors (NMSE) of the phantom, two line sources located in a 99mTc filled cylinder, were used. NMSE of the "Butterworth" filter, "Wiener" filter, and filtering based on a power spectrum were 0.77, 0.83, and 0.76 respectively. Clinically, brain SPECT images utilizing this new restoration filter improved the contrast. Thus, this filter may be useful in diagnosis of SPECT images.

  15. Restoration filtering based on projection power spectrum for single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Kubo, Naoki

    1995-01-01

    To improve the quality of single-photon emission computed tomographic (SPECT) images, a restoration filter has been developed. This filter was designed according to practical 'least squares filter' theory. It is necessary to know the object power spectrum and the noise power spectrum. The power spectrum is estimated from the power spectrum of a projection, when the high-frequency power spectrum of a projection is adequately approximated as a polynomial exponential expression. A study of the restoration with the filter based on a projection power spectrum was conducted, and compared with that of the 'Butterworth' filtering method (cut-off frequency of 0.15 cycles/pixel), and 'Wiener' filtering (signal-to-noise power spectrum ratio was a constant). Normalized mean-squared errors (NMSE) of the phantom, two line sources located in a 99m Tc filled cylinder, were used. NMSE of the 'Butterworth' filter, 'Wiener' filter, and filtering based on a power spectrum were 0.77, 0.83, and 0.76 respectively. Clinically, brain SPECT images utilizing this new restoration filter improved the contrast. Thus, this filter may be useful in diagnosis of SPECT images. (author)

  16. New Collaborative Filtering Algorithms Based on SVD++ and Differential Privacy

    OpenAIRE

    Xian, Zhengzheng; Li, Qiliang; Li, Gai; Li, Lei

    2017-01-01

    Collaborative filtering technology has been widely used in the recommender system, and its implementation is supported by the large amount of real and reliable user data from the big-data era. However, with the increase of the users’ information-security awareness, these data are reduced or the quality of the data becomes worse. Singular Value Decomposition (SVD) is one of the common matrix factorization methods used in collaborative filtering, which introduces the bias information of users a...

  17. Protozoa and metazoa relations to technological conditions of non-woven textile filters for wastewater treatment.

    Science.gov (United States)

    Spychała, Marcin; Sowińska, Aleksandra; Starzyk, Justyna; Masłowski, Adam

    2015-01-01

    The objective of this study was a preliminary identification of basic groups of micro-organisms in the cross-sectional profile of geotextile filters for septic tank effluent (STE) treatment and their relations to technological conditions. Reactors with textile filters treating wastewater were investigated on a semi-technical scale. Filters were vertically situated and STE was filtered through them under hydrostatic pressure at a wastewater surface height of 7-20 cm. Filters were made of four layers of non-woven TS 20 geotextile of 0.9 mm thickness. Various groups of organisms were observed; the most abundant group comprised free-swimming and crawling ciliates, less abundant were stalked ciliates and the least numerous were nematodes. The individual counts of all groups of micro-organisms investigated during the study were variable according to time and space. The high abundance of Opercularia, a commonly observed genus of stalked ciliates, was related to the high efficiency of wastewater treatment and dissolved oxygen concentration of about 1.0 g/m3. Numbers of free-swimming and crawling ciliates had a tendency to decrease in relation to the depth of filter cross-sectional profile. The variability in counts of particular groups of organisms could be related to the local stress conditions. No correlation between identified organism count and total mass concentration in the cross-sectional filter profile was found.

  18. Comammox Nitrospira are abundant ammonia oxidizers in diverse groundwater‐fed rapid sand filter communities

    DEFF Research Database (Denmark)

    Fowler, Susan Jane; Palomo, Alejandro; Dechesne, Arnaud

    2018-01-01

    quantification and diversity assessement of both comammox Nitrospira clades. The primers cover a wide range of comammox diversity, spanning all available high quality sequences. We applied these primers to 12 groundwater‐fed rapid sand filters, and found comammox Nitrospira to be abundant in all filters. Clade B...

  19. Assessment of TS-1, a thick cane mutant

    International Nuclear Information System (INIS)

    Shama Rao, H.K.

    1979-01-01

    A true breeding thick cane mutant TS-1, induced by radiations, was obtained in variety Co-419. TS-1 was found to be superior to Co-419 with respect to cane size, weight, yield and juice quality. The thick canes of TS-1 were found to be solid even at 14 months age and so also their ratoons. The tillering habit of TS-1 has a definite advantage over other varieties with respect to easy intercultural field operations. TS-1 is now being tested under various agroclimatic zones in Karnataka, Maharashtra and U.P. (auth.)

  20. A Study of Parallel Operation of an active Filter and passive Filters

    DEFF Research Database (Denmark)

    Chen, Zhe; Blaabjerg, Frede; Pedersen, John Kim

    2002-01-01

    This paper reports investigations of the parallel operations of a current controlled active filter and passive filters in a system with current harmonic sources. The task of reactive power and harmonic compensation is shared by the active filter and passive filters. The passive filters are used...... arrangements of the active and passive filters can operate relatively independently, also the compensation flexibility of the active filter can be fully exploited, such as one active filter for several harmonic sources.The simulation studies on various systems have been performed to evaluate the effectiveness...... of the systems. The results show that the power factor is corrected by the passive filters, harmonics are minimized by both active and passive filters and overloading of the filter system can be avoided....

  1. Superharmonic imaging with chirp coded excitation: filtering spectrally overlapped harmonics.

    Science.gov (United States)

    Harput, Sevan; McLaughlan, James; Cowell, David M J; Freear, Steven

    2014-11-01

    Superharmonic imaging improves the spatial resolution by using the higher order harmonics generated in tissue. The superharmonic component is formed by combining the third, fourth, and fifth harmonics, which have low energy content and therefore poor SNR. This study uses coded excitation to increase the excitation energy. The SNR improvement is achieved on the receiver side by performing pulse compression with harmonic matched filters. The use of coded signals also introduces new filtering capabilities that are not possible with pulsed excitation. This is especially important when using wideband signals. For narrowband signals, the spectral boundaries of the harmonics are clearly separated and thus easy to filter; however, the available imaging bandwidth is underused. Wideband excitation is preferable for harmonic imaging applications to preserve axial resolution, but it generates spectrally overlapping harmonics that are not possible to filter in time and frequency domains. After pulse compression, this overlap increases the range side lobes, which appear as imaging artifacts and reduce the Bmode image quality. In this study, the isolation of higher order harmonics was achieved in another domain by using the fan chirp transform (FChT). To show the effect of excitation bandwidth in superharmonic imaging, measurements were performed by using linear frequency modulated chirp excitation with varying bandwidths of 10% to 50%. Superharmonic imaging was performed on a wire phantom using a wideband chirp excitation. Results were presented with and without applying the FChT filtering technique by comparing the spatial resolution and side lobe levels. Wideband excitation signals achieved a better resolution as expected, however range side lobes as high as -23 dB were observed for the superharmonic component of chirp excitation with 50% fractional bandwidth. The proposed filtering technique achieved >50 dB range side lobe suppression and improved the image quality without

  2. Passive Power Filters

    CERN Document Server

    Künzi, R.

    2015-06-15

    Power converters require passive low-pass filters which are capable of reducing voltage ripples effectively. In contrast to signal filters, the components of power filters must carry large currents or withstand large voltages, respectively. In this paper, three different suitable filter struc tures for d.c./d.c. power converters with inductive load are introduced. The formulas needed to calculate the filter components are derived step by step and practical examples are given. The behaviour of the three discussed filters is compared by means of the examples. P ractical aspects for the realization of power filters are also discussed.

  3. Improved virus removal in ceramic depth filters modified with MgO.

    Science.gov (United States)

    Michen, Benjamin; Fritsch, Johannes; Aneziris, Christos; Graule, Thomas

    2013-02-05

    Ceramic filters, working on the depth filtration principle, are known to improve drinking water quality by removing human pathogenic microorganisms from contaminated water. However, these microfilters show no sufficient barrier for viruses having diameters down to 20 nm. Recently, it was shown that the addition of positively charged materials, for example, iron oxyhydroxide, can improve virus removal by adsorption mechanisms. In this work, we modified a common ceramic filter based on diatomaceous earth by introducing a novel virus adsorbent material, magnesium oxyhydroxide, into the filter matrix. Such filters showed an improved removal of about 4-log in regard to bacteriophages MS2 and PhiX174. This is explained with the electrostatic enhanced adsorption approach that is the favorable adsorption of negatively charged viruses onto positively charged patches in an otherwise negatively charged filter matrix. Furthermore, we provide theoretical evidence applying calculations according to Derjaguin-Landau-Verwey-Overbeek theory to strengthen our experimental results. However, modified filters showed a significant variance in virus removal efficiency over the course of long-term filtration experiments with virus removal increasing with filter operation time (or filter aging). This is explained by transformational changes of MgO in the filter upon contact with water. It also demonstrates that filter history is of great concern when filters working on the adsorption principles are evaluated in regard to their retention performance as their surface characteristics may alter with use.

  4. Fabricating high-resolution offset color-filter black matrix by integrating heterostructured substrate with inkjet printing

    International Nuclear Information System (INIS)

    Lu, Guo-Shin; You, Po-Chin; Lin, Kai-Lun; Hong, Chien-Chong; Liou, Tong-Miin

    2014-01-01

    This paper presents a self-aligning ink by integrating an inkjet printing technique and heterostructures to fabricate a black matrix with a micrometer-scale tunable thickness. The black matrix is a grid-like structure used in color filters. Traditionally, a black matrix has been fabricated using photolithography techniques, the disadvantages of which are high material consumption, less fabrication flexibility, complex processing procedures, and high chemical pollution. Inkjet printing technology has garnered attention because of its low material costs, high fabrication flexibility, and reduced processing procedures and pollution. In this study, a fabricating process combining an inkjet printing technique with heterostructures to form stripe-arranged and delta-arranged thickness-tunable black matrices has been demonstrated. The deformation and self-aligning process of ink droplet impingement onto gutters are driven by designed heterogeneous surface properties. The minimum track width attained is 10 µm, which is competitive for color filter resolutions for thin-film transistor liquid crystal displays. The developed technology surmounts the bottlenecks of inkjet printing resolution, and saves more than 75% black material than modern photolithography. (paper)

  5. Three-dimensional anisotropic adaptive filtering of projection data for noise reduction in cone beam CT

    Energy Technology Data Exchange (ETDEWEB)

    Maier, Andreas; Wigstroem, Lars; Hofmann, Hannes G.; Hornegger, Joachim; Zhu Lei; Strobel, Norbert; Fahrig, Rebecca [Department of Radiology, Stanford University, Stanford, California 94305 (United States); Department of Radiology, Stanford University, Stanford, California 94305 (United States) and Center for Medical Image Science and Visualization, Linkoeping University, Linkoeping (Sweden); Pattern Recognition Laboratory, Department of Computer Science, Friedrich-Alexander University of Erlangen-Nuremberg, 91054, Erlangen (Germany); Nuclear and Radiological Engineering and Medical Physics Programs, George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332 (United States); Siemens AG Healthcare, Forchheim 91301 (Germany); Department of Radiology, Stanford University, Stanford, California 94305 (United States)

    2011-11-15

    Purpose: The combination of quickly rotating C-arm gantry with digital flat panel has enabled the acquisition of three-dimensional data (3D) in the interventional suite. However, image quality is still somewhat limited since the hardware has not been optimized for CT imaging. Adaptive anisotropic filtering has the ability to improve image quality by reducing the noise level and therewith the radiation dose without introducing noticeable blurring. By applying the filtering prior to 3D reconstruction, noise-induced streak artifacts are reduced as compared to processing in the image domain. Methods: 3D anisotropic adaptive filtering was used to process an ensemble of 2D x-ray views acquired along a circular trajectory around an object. After arranging the input data into a 3D space (2D projections + angle), the orientation of structures was estimated using a set of differently oriented filters. The resulting tensor representation of local orientation was utilized to control the anisotropic filtering. Low-pass filtering is applied only along structures to maintain high spatial frequency components perpendicular to these. The evaluation of the proposed algorithm includes numerical simulations, phantom experiments, and in-vivo data which were acquired using an AXIOM Artis dTA C-arm system (Siemens AG, Healthcare Sector, Forchheim, Germany). Spatial resolution and noise levels were compared with and without adaptive filtering. A human observer study was carried out to evaluate low-contrast detectability. Results: The adaptive anisotropic filtering algorithm was found to significantly improve low-contrast detectability by reducing the noise level by half (reduction of the standard deviation in certain areas from 74 to 30 HU). Virtually no degradation of high contrast spatial resolution was observed in the modulation transfer function (MTF) analysis. Although the algorithm is computationally intensive, hardware acceleration using Nvidia's CUDA Interface provided an 8

  6. Three-dimensional anisotropic adaptive filtering of projection data for noise reduction in cone beam CT

    International Nuclear Information System (INIS)

    Maier, Andreas; Wigstroem, Lars; Hofmann, Hannes G.; Hornegger, Joachim; Zhu Lei; Strobel, Norbert; Fahrig, Rebecca

    2011-01-01

    Purpose: The combination of quickly rotating C-arm gantry with digital flat panel has enabled the acquisition of three-dimensional data (3D) in the interventional suite. However, image quality is still somewhat limited since the hardware has not been optimized for CT imaging. Adaptive anisotropic filtering has the ability to improve image quality by reducing the noise level and therewith the radiation dose without introducing noticeable blurring. By applying the filtering prior to 3D reconstruction, noise-induced streak artifacts are reduced as compared to processing in the image domain. Methods: 3D anisotropic adaptive filtering was used to process an ensemble of 2D x-ray views acquired along a circular trajectory around an object. After arranging the input data into a 3D space (2D projections + angle), the orientation of structures was estimated using a set of differently oriented filters. The resulting tensor representation of local orientation was utilized to control the anisotropic filtering. Low-pass filtering is applied only along structures to maintain high spatial frequency components perpendicular to these. The evaluation of the proposed algorithm includes numerical simulations, phantom experiments, and in-vivo data which were acquired using an AXIOM Artis dTA C-arm system (Siemens AG, Healthcare Sector, Forchheim, Germany). Spatial resolution and noise levels were compared with and without adaptive filtering. A human observer study was carried out to evaluate low-contrast detectability. Results: The adaptive anisotropic filtering algorithm was found to significantly improve low-contrast detectability by reducing the noise level by half (reduction of the standard deviation in certain areas from 74 to 30 HU). Virtually no degradation of high contrast spatial resolution was observed in the modulation transfer function (MTF) analysis. Although the algorithm is computationally intensive, hardware acceleration using Nvidia's CUDA Interface provided an 8.9-fold

  7. A study on image quality and exposure dose of hard radiation radiography of the chest

    International Nuclear Information System (INIS)

    Hayashi, Taro; Ishida, Yuji; Maeda, Mika; Sakurai, Tatsuya; Kim, Chung Woon; Hwang, Jong Sun

    1991-01-01

    Experiment was conducted on the image quality and exposure dose following replacement of CaWO 4 system screen BH - III and BX - III which have so far been used for high - voltage hard - radiation quality radiography, with rare earth system screen KO750, combined with high contrast film SRH, while additional filter was altered, Cu 0.8 mm + Al 1.4 mm(HVL : AI 8.8 mm), Cu 1.3 mm + AI 1.0mm(HVL: AI 10.6mm) and Cu 1.8mm + AI 1.5mm(HVL: AI 11.4mm). AS a result, visual evaluation did not detect extreme changes in image quality under the respective condition (HVL : Al 8.8 mm ∼ AI 11.4 mm). It was noted, however, that surface exposure dose declined with an increase in the thickness of the additional filter, as it was 18.9 μGy at HVL Al 8.8 mm, 17.5 μGy at Al 10.6 mm and 15.7 μGy at Al 11.4 mm. Considering the limited rating of X-ray equipment and wear of machinery, however, the range of Cu 1.3 mm ∼ l.8 mm + AI 1.0 mm ∼ 1.5 mm(1/16 VL ∼ 1/32 VL) seemed to be a limit

  8. Analysis of Shrinkage on Thick Plate Part using Genetic Algorithm

    Directory of Open Access Journals (Sweden)

    Najihah S.N.

    2016-01-01

    Full Text Available Injection moulding is the most widely used processes in manufacturing plastic products. Since the quality of injection improves plastic parts are mostly influenced by process conditions, the method to determine the optimum process conditions becomes the key to improving the part quality. This paper presents a systematic methodology to analyse the shrinkage of the thick plate part during the injection moulding process. Genetic Algorithm (GA method was proposed to optimise the process parameters that would result in optimal solutions of optimisation goals. Using the GA, the shrinkage of the thick plate part was improved by 39.1% in parallel direction and 17.21% in the normal direction of melt flow.

  9. Design of a micromachined terahertz electromagnetic crystals (EMXT) channel-drop filter on silicon-substrate

    Science.gov (United States)

    Zhou, Kai; Liu, Yong; Si, Liming; Lv, Xin

    2013-08-01

    An integrated 0.5 THz electromagnetic crystals(EMXT) channel-drop filter based on PBG structure is presented in this paper. A channel-drop filter is a device in which a narrow bandwidth is redirected to another "drop" waveguide while other frequencies are unaffected. It's capable of extracting a certain frequency from a continuous spectrum in the bus channel and passing it to the test channel. It has potential applications in photonic integrated circuits, radio astronomy, THz spectroscopy, THz communication and remote sensing radar receiver. PBG structures(or photonic crystals) are periodic structures which possess band gaps, where the electromagnetic wave of certain ranges of frequencies cannot pass through and is reflected. The proposed channel-drop filter consists of input waveguide,output waveguide and PBG structure. The proposed filter is simulated using the finite element method and can be fabricated by micro-electromechanical systems (MEMS) technology,due to its low cost, high performance and high processing precision.The filter operation principle and fabrication process are discussed.The simulation results show its ability to filter the frequency of 496GHz with a linewidth of approximately 4GHz and transmission of 27.2 dB above background.The loss at resonant frequency is less than 1dB considering the thickness and roughness of gold layer required by the MEMS process.The channel drop efficiency is 84%.

  10. Simplified Method for Groundwater Treatment Using Dilution and Ceramic Filter

    Science.gov (United States)

    Musa, S.; Ariff, N. A.; Kadir, M. N. Abdul; Denan, F.

    2016-07-01

    Groundwater is one of the natural resources that is not susceptible to pollutants. However, increasing activities of municipal, industrial, agricultural or extreme land use activities have resulted in groundwater contamination as occured at the Research Centre for Soft Soil Malaysia (RECESS), Universiti Tun Hussein Onn Malaysia (UTHM). Thus, aims of this study is to treat groundwater by using rainwater and simple ceramic filter as a treatment agent. The treatment uses rain water dilution, ceramic filters and combined method of dilute and filtering as an alternate treatment which are simple and more practical compared to modern or chemical methods. The water went through dilution treatment processes able to get rid of 57% reduction compared to initial condition. Meanwhile, the water that passes through the filtering process successfully get rid of as much as 86% groundwater parameters where only chloride does not pass the standard. Favorable results for the combination methods of dilution and filtration methods that can succesfully eliminate 100% parameters that donot pass the standards of the Ministry of Health and the Interim National Drinking Water Quality Standard such as those found in groundwater in RECESS, UTHM especially sulfate and chloride. As a result, it allows the raw water that will use clean drinking water and safe. It also proves that the method used in this study is very effective in improving the quality of groundwater.

  11. Particle Kalman Filtering: A Nonlinear Bayesian Framework for Ensemble Kalman Filters*

    KAUST Repository

    Hoteit, Ibrahim

    2012-02-01

    This paper investigates an approximation scheme of the optimal nonlinear Bayesian filter based on the Gaussian mixture representation of the state probability distribution function. The resulting filter is similar to the particle filter, but is different from it in that the standard weight-type correction in the particle filter is complemented by the Kalman-type correction with the associated covariance matrices in the Gaussian mixture. The authors show that this filter is an algorithm in between the Kalman filter and the particle filter, and therefore is referred to as the particle Kalman filter (PKF). In the PKF, the solution of a nonlinear filtering problem is expressed as the weighted average of an “ensemble of Kalman filters” operating in parallel. Running an ensemble of Kalman filters is, however, computationally prohibitive for realistic atmospheric and oceanic data assimilation problems. For this reason, the authors consider the construction of the PKF through an “ensemble” of ensemble Kalman filters (EnKFs) instead, and call the implementation the particle EnKF (PEnKF). It is shown that different types of the EnKFs can be considered as special cases of the PEnKF. Similar to the situation in the particle filter, the authors also introduce a resampling step to the PEnKF in order to reduce the risk of weights collapse and improve the performance of the filter. Numerical experiments with the strongly nonlinear Lorenz-96 model are presented and discussed.

  12. Achieving high mobility ZnO : Al at very high growth rates by dc filtered cathodic arc deposition

    International Nuclear Information System (INIS)

    Mendelsberg, R J; Lim, S H N; Wallig, J; Anders, A; Zhu, Y K; Milliron, D J

    2011-01-01

    Achieving a high growth rate is paramount for making large-area transparent conducting oxide coatings at a low cost. Unfortunately, the quality of thin films grown by most techniques degrades as the growth rate increases. Filtered dc cathodic arc is a lesser known technique which produces a stream of highly ionized plasma, in stark contrast to the neutral atoms produced by standard sputter sources. Ions bring a large amount of potential energy to the growing surface which is in the form of heat, not momentum. By minimizing the distance from cathode to substrate, the high ion flux gives a very high effective growth temperature near the film surface without causing damage from bombardment. The high surface temperature is a direct consequence of the high growth rate and allows for high-quality crystal growth. Using this technique, 500-1300 nm thick and highly transparent ZnO : Al films were grown on glass at rates exceeding 250 nm min -1 while maintaining resistivity below 5 x 10 -4 Ω cm with electron mobility as high as 60 cm 2 V -1 s -1 . (fast track communication)

  13. The Science Advantage of a Redder Filter for WFIRST

    Science.gov (United States)

    Bauer, James; Stauffer, John; Milam, Stefanie N.; Holler, Bryan J.

    2018-01-01

    WFIRST will be capable of providing Hubble-quality imaging performance over several thousand square degrees of the sky. The wide-area, high spatial resolution survey data from WFIRST will be unsurpassed for probably many decades into the future. With the current baseline design, the WFIRST filter complement will extend from the bluest wavelength allowed by the optical design to a reddest filter (F184W) that has a red cutoff at 2.0 microns. Extension of the imaging capabilities even slightly beyond the 2.0 micron wavelength cut-off would provide significant advantages over the presently proposed science for objects both near and far. The inclusion of a Ks (2.0-2.3 micron) filter would result in a wider range and more comprehensive set of Solar System investigations. It would also extend the range of higher-redshift population studies. In this poster, we outline some of the science advantages for adding a K filter, similar in bandpass to the 2MASS Ks filter, in order to extend the wavelength range for WFIRST as far to the red as the thermal performance of the spacecraft allows.

  14. Rectifier Filters

    Directory of Open Access Journals (Sweden)

    Y. A. Bladyko

    2010-01-01

    Full Text Available The paper contains definition of a smoothing factor which is suitable for any rectifier filter. The formulae of complex smoothing factors have been developed for simple and complex passive filters. The paper shows conditions for application of calculation formulae and filters

  15. Spectral characterization in deep UV of an improved imaging KDP acousto-optic tunable filter

    International Nuclear Information System (INIS)

    Gupta, Neelam; Voloshinov, Vitaly

    2014-01-01

    Recently, we developed a number of high quality noncollinear acousto-optic tunable filter (AOTF) cells in different birefringent materials with UV imaging capability. Cells based on a single crystal of KDP (potassium dihydrophosphate) had the best transmission efficiency and the optical throughput needed to acquire high quality spectral images at wavelengths above 220 nm. One of the main limitations of these imaging filters was their small angular aperture in air, limited to about 1.0°. In this paper, we describe an improved imaging KDP AOTF operating from the deep UV to the visible region of the spectrum. The linear and angular apertures of the new filter are 10 × 10 mm 2 and 1.8°, respectively. The spectral tuning range is 205–430 nm with a 60 cm −1 spectral resolution. We describe the filter and present experimental results on imaging using both a broadband source and a number of light emitting diodes (LEDs) in the UV, and include the measured spectra of these LEDs obtained with a collinear SiO 2 filter-based spectrometer operating above 255 nm. (paper)

  16. Resonant TMR inversion in LiF/EuS based spin-filter tunnel junctions

    Directory of Open Access Journals (Sweden)

    Fen Liu

    2016-08-01

    Full Text Available Resonant tunneling can lead to inverse tunnel magnetoresistance when impurity levels rather than direct tunneling dominate the transport process. We fabricated hybrid magnetic tunnel junctions of CoFe/LiF/EuS/Ti, with an epitaxial LiF energy barrier joined with a polycrystalline EuS spin-filter barrier. Due to the water solubility of LiF, the devices were fully packaged in situ. The devices showed sizeable positive TMR up to 16% at low bias voltages but clearly inverted TMR at higher bias voltages. The TMR inversion depends sensitively on the thickness of LiF, and the tendency of inversion disappears when LiF gets thick enough and recovers its intrinsic properties.

  17. Adaptive robust Kalman filtering for precise point positioning

    International Nuclear Information System (INIS)

    Guo, Fei; Zhang, Xiaohong

    2014-01-01

    The optimality of precise point postioning (PPP) solution using a Kalman filter is closely connected to the quality of the a priori information about the process noise and the updated mesurement noise, which are sometimes difficult to obtain. Also, the estimation enviroment in the case of dynamic or kinematic applications is not always fixed but is subject to change. To overcome these problems, an adaptive robust Kalman filtering algorithm, the main feature of which introduces an equivalent covariance matrix to resist the unexpected outliers and an adaptive factor to balance the contribution of observational information and predicted information from the system dynamic model, is applied for PPP processing. The basic models of PPP including the observation model, dynamic model and stochastic model are provided first. Then an adaptive robust Kalmam filter is developed for PPP. Compared with the conventional robust estimator, only the observation with largest standardized residual will be operated by the IGG III function in each iteration to avoid reducing the contribution of the normal observations or even filter divergence. Finally, tests carried out in both static and kinematic modes have confirmed that the adaptive robust Kalman filter outperforms the classic Kalman filter by turning either the equivalent variance matrix or the adaptive factor or both of them. This becomes evident when analyzing the positioning errors in flight tests at the turns due to the target maneuvering and unknown process/measurement noises. (paper)

  18. Studies of the Fission Integrals of U-{sup 235} and Pu-{sup 239} with Cadmium and Filters

    Energy Technology Data Exchange (ETDEWEB)

    Hellstrand, E

    1965-04-15

    The resonance fissions in U{sup 235} and Pu{sup 239} have been studied using cadmium and boron filters. Fission chambers were used as detectors and the experiments were performed in beam geometry. The neutron energy distribution in the beams transmitted through the different filters was determined with a fast chopper. From the cadmium filter, measurements the fission resonance integrals were determined. The values obtained were 278{+-}9 b for U{sup 235} and 301{+-}10 b for Pu{sup 239}; 0.5 eV < E < 1 MeV. Complementary Pu{sup 239} measurements were made in which the fission events were detected from the fission product activity in irradiated foils. Contrary to what has been reported elsewhere the value of the Pu{sup 239} resonance integral, found in this way, agreed well with that obtained from the fission chamber measurement. The experiments with the boron filters yielded results which, for the thin filter, agreed well with those calculated from the cross section data given in the Karlsruhe compilation. The discrepancy was larger for the thick filter but the values did not disagree outside the common limits of error.

  19. Image quality dependence on thickness of sliced rat kidney taken by a simplest DEI construction

    International Nuclear Information System (INIS)

    Li Gang; Chen Zhihua; Wu Ziyu; Ando, M.; Pan Lin; Wang, J.Y.; Jiang, X.M.

    2005-01-01

    The excised rat kidney slices were investigated using a simplified diffraction-enhanced imaging (DEI) configuration with only two crystals: the first one working as monochromator and the second one working as analyzer in the Bragg geometry that was developed at Beijing Synchrotron Radiation Facility (BSRF). Many fine anatomic structures of the sliced rat kidneys with thickness of 2mm and 120μm can be distinguished clearly in the DEI images that were obtained at the shoulder of a rocking curve. The authors would like to emphasize that the thick and thin slices DEI provides very different images; in the thick sample only the structure with the big density gradient or that near the surface where X-ray comes out can be distinguished, while in the thin ones some fine structures, which can not be distinguished at the thick sample under the same condition, can be seen very clearly. The reason related with the counteraction of δ(x,y,z) gradient in the integral process along the X-ray path inside the thick sample is discussed

  20. Image quality dependence on thickness of sliced rat kidney taken by a simplest DEI construction

    Energy Technology Data Exchange (ETDEWEB)

    Li Gang [Institute of High Energy Physics, Chinese Academy of Science, Yuquan Rd. No 19, Beijing 100039 (China)]. E-mail: lig@ihep.ac.cn; Chen Zhihua [China-Japan Friendship Institute of Clinical Medical Science, Yinghua Rd., Beijing 100029 (China); Wu Ziyu [Institute of High Energy Physics, Chinese Academy of Science, Yuquan Rd. No 19, Beijing 100039 (China); Ando, M. [Photon Factory, KEK, Oho 1-1, Tsukuba, Ibaraki 305-0801 (Japan); Pan Lin [China-Japan Friendship Institute of Clinical Medical Science, Yinghua Rd., Beijing 100029 (China); Wang, J.Y. [Institute of High Energy Physics, Chinese Academy of Science, Yuquan Rd. No 19, Beijing 100039 (China); Jiang, X.M. [Institute of High Energy Physics, Chinese Academy of Science, Yuquan Rd. No 19, Beijing 100039 (China)

    2005-08-11

    The excised rat kidney slices were investigated using a simplified diffraction-enhanced imaging (DEI) configuration with only two crystals: the first one working as monochromator and the second one working as analyzer in the Bragg geometry that was developed at Beijing Synchrotron Radiation Facility (BSRF). Many fine anatomic structures of the sliced rat kidneys with thickness of 2mm and 120{mu}m can be distinguished clearly in the DEI images that were obtained at the shoulder of a rocking curve. The authors would like to emphasize that the thick and thin slices DEI provides very different images; in the thick sample only the structure with the big density gradient or that near the surface where X-ray comes out can be distinguished, while in the thin ones some fine structures, which can not be distinguished at the thick sample under the same condition, can be seen very clearly. The reason related with the counteraction of {delta}(x,y,z) gradient in the integral process along the X-ray path inside the thick sample is discussed.

  1. Sorption and desorption of arsenic to ferrihydrite in a sand filter.

    Science.gov (United States)

    Jessen, Soren; Larsen, Flemming; Koch, Christian Bender; Arvin, Erik

    2005-10-15

    Elevated arsenic concentrations in drinking water occur in many places around the world. Arsenic is deleterious to humans, and consequently, As water treatment techniques are sought. To optimize arsenic removal, sorption and desorption processes were studied at a drinking water treatment plant with aeration and sand filtration of ferrous iron rich groundwater at Elmevej Water Works, Fensmark, Denmark. Filter sand and pore water were sampled along depth profiles in the filters. The sand was coated with a 100-300 microm thick layer of porous Si-Ca-As-contaning iron oxide (As/Fe = 0.17) with locally some manganese oxide. The iron oxide was identified as a Si-stabilized abiotically formed two-line ferrihydrite with a magnetic hyperfine field of 45.8 T at 5 K. The raw water has an As concentration of 25 microg/L, predominantly as As(II). As the water passes through the filters, As(III) is oxidized to As(V) and the total concentrations drop asymptotically to a approximately 15 microg/L equilibrium concentration. Mn is released to the pore water, indicating the existence of reactive manganese oxides within the oxide coating, which probably play a role for the rapid As(III) oxidation. The As removal in the sand filters appears controlled by sorption equilibrium onto the ferrihydrite. By addition of ferrous chloride (3.65 mg of Fe(II)/L) to the water stream between two serially connected filters, a 3 microg/L As concentration is created in the water that infiltrates into the second sand filter. However, as water flow is reestablished through the second filter, As desorbs from the ferrihydrite and increases until the 15 microg/L equilibrium concentration. Sequential chemical extractions and geometrical estimates of the fraction of surface-associated As suggest that up to 40% of the total As can be remobilized in response to changes in the water chemistry in the sand filter.

  2. Detecting Power Voltage Dips using Tracking Filters - A Comparison against Kalman

    Directory of Open Access Journals (Sweden)

    STANCIU, I.-R.

    2012-11-01

    Full Text Available Due of its significant economical impact, Power-Quality (PQ analysis is an important domain today. Severe voltage distortions affect the consumers and disturb their activity. They may be caused by short circuits (in this case the voltage drops significantly or by varying loads (with a smaller drop. These two types are the PQ currently issues. Monitoring these phenomena (called dips or sags require powerful techniques. Digital Signal Processing (DSP algorithms are currently employed to fulfill this task. Discrete Wavelet Transforms, (and variants, Kalman filters, and S-Transform are currently proposed by researchers to detect voltage dips. This paper introduces and examines a new tool to detect voltage dips: the so-called tracking filters. Discovered and tested during the cold war, they can estimate a parameter of interest one-step-ahead based on the previously observed values. Two filters are implemented. Their performance is assessed by comparison against the Kalman filter?s results.

  3. Drainage filters and constructed wetlands to mitigate site-specific nutrient losses

    DEFF Research Database (Denmark)

    Kjærgaard, Charlotte; Hoffmann, Carl Christian; Iversen, Bo Vangsø

    Despite substantial efforts, the leaching of nutrients from agricultural land is still a serious and costly environmental problem in Denmark and elsewhere. The quality goals of the European Water Framework Directive (WFD) for the aquatic environment require a substantial reduction of diffuse nutr...... drainage. The project studies different approaches of implementing the filter technologies including drainage well or drainage pipe filters as well as surface-flow and sub-surface flow constructed wetlands....

  4. Design of reproducible polarized and non-polarized edge filters using genetic algorithm

    International Nuclear Information System (INIS)

    Ejigu, Efrem Kebede; Lacquet, B M

    2010-01-01

    Recent advancement in optical fibre communications technology is partly due to the advancement of optical thin film technology. The advancement of optical thin film technology includes the development of new and existing optical filter design methods. The genetic algorithm is one of the new design methods that show promising results in designing a number of complicated design specifications. It is the finding of this study that the genetic algorithm design method, through its optimization capability, can give more reliable and reproducible designs of any specifications. The design method in this study optimizes the thickness of each layer to get to the best possible solution. Its capability and unavoidable limitations in designing polarized and non-polarized edge filters from absorptive and dispersive materials is well demonstrated. It is also demonstrated that polarized and non-polarized designs from the genetic algorithm are reproducible with great success. This research has accomplished the great task of formulating a computer program using the genetic algorithm in a Matlab environment for the design of a reproducible polarized and non-polarized filters of any sort from any kind of materials

  5. Elastic thickness determination based on Vening Meinesz-Moritz and flexural theories of isostasy

    Science.gov (United States)

    Eshagh, Mehdi

    2018-06-01

    Elastic thickness (Te) is one of mechanical properties of the Earth's lithosphere. The lithosphere is assumed to be a thin elastic shell, which is bended under the topographic, bathymetric and sediment loads on. The flexure of this elastic shell depends on its thickness or Te. Those shells having larger Te flex less. In this paper, a forward computational method is presented based on the Vening Meinesz-Moritz (VMM) and flexural theories of isostasy. Two Moho flexure models are determined using these theories, considering effects of surface and subsurface loads. Different values are selected for Te in the flexural method to see by which one, the closest Moho flexure to that of the VMM is achieved. The effects of topographic/bathymetric, sediments and crustal crystalline masses, and laterally variable upper mantle density, Young's modulus and Poisson's ratio are considered in whole computational process. Our mathematical derivations are based on spherical harmonics, which can be used to estimate Te at any single point, meaning that there is no edge effect in the method. However, the Te map needs to be filtered to remove noise at some points. A median filter with a window size of 5° × 5° and overlap of 4° works well for this purpose. The method is applied to estimate Te over South America using the data of CRUST1.0 and a global gravity model.

  6. Mecoprop (MCPP) removal in full-scale rapid sand filters at a groundwater-based waterworks

    DEFF Research Database (Denmark)

    Hedegaard, Mathilde Jørgensen; Arvin, Erik; Corfitzen, Charlotte B.

    2014-01-01

    and secondary rapid sand filters. Water quality parameters were measured throughout the waterworks, and they behaved as designed for. MCPP was removed in secondary rapid sand filters — removal was the greatest in the sand filters in the filter line with the highest contact time (63min). In these secondary sand...... in the full-scale system. Therefore, microcosms were set up with filter sand, water and 14C-labelled MCPP at an initial concentration of 0.2μg/L. After 24h, 79–86% of the initial concentration of MCPP was removed. Sorption removed 11–15%, while the remaining part was removed by microbial processes, leading...... to a complete mineralisation of 13–18%. Microbial removal in the filter sand was similar at different depths of the rapid sand filter, while the amount of MCPP which adsorbed to the filter sand after 48h decreased with depth from 21% of the initial MCPP in the top layer to 7% in the bottom layer...

  7. Speckle reduction in echocardiography by temporal compounding and anisotropic diffusion filtering

    Science.gov (United States)

    Giraldo-Guzmán, Jader; Porto-Solano, Oscar; Cadena-Bonfanti, Alberto; Contreras-Ortiz, Sonia H.

    2015-01-01

    Echocardiography is a medical imaging technique based on ultrasound signals that is used to evaluate heart anatomy and physiology. Echocardiographic images are affected by speckle, a type of multiplicative noise that obscures details of the structures, and reduces the overall image quality. This paper shows an approach to enhance echocardiography using two processing techniques: temporal compounding and anisotropic diffusion filtering. We used twenty echocardiographic videos that include one or three cardiac cycles to test the algorithms. Two images from each cycle were aligned in space and averaged to obtain the compound images. These images were then processed using anisotropic diffusion filters to further improve their quality. Resultant images were evaluated using quality metrics and visual assessment by two medical doctors. The average total improvement on signal-to-noise ratio was up to 100.29% for videos with three cycles, and up to 32.57% for videos with one cycle.

  8. Retina-Inspired Filter.

    Science.gov (United States)

    Doutsi, Effrosyni; Fillatre, Lionel; Antonini, Marc; Gaulmin, Julien

    2018-07-01

    This paper introduces a novel filter, which is inspired by the human retina. The human retina consists of three different layers: the Outer Plexiform Layer (OPL), the inner plexiform layer, and the ganglionic layer. Our inspiration is the linear transform which takes place in the OPL and has been mathematically described by the neuroscientific model "virtual retina." This model is the cornerstone to derive the non-separable spatio-temporal OPL retina-inspired filter, briefly renamed retina-inspired filter, studied in this paper. This filter is connected to the dynamic behavior of the retina, which enables the retina to increase the sharpness of the visual stimulus during filtering before its transmission to the brain. We establish that this retina-inspired transform forms a group of spatio-temporal Weighted Difference of Gaussian (WDoG) filters when it is applied to a still image visible for a given time. We analyze the spatial frequency bandwidth of the retina-inspired filter with respect to time. It is shown that the WDoG spectrum varies from a lowpass filter to a bandpass filter. Therefore, while time increases, the retina-inspired filter enables to extract different kinds of information from the input image. Finally, we discuss the benefits of using the retina-inspired filter in image processing applications such as edge detection and compression.

  9. Investigation into the optimal use of automatic optimisation of parameters (AOP) for mammography

    International Nuclear Information System (INIS)

    Herley, J.; Tan, W.

    2004-01-01

    Full text: Automatic Optimisation of Parameters (AOP) is an AEC function offered on GE Medical Systems mammography units. It optimizes x-ray exposure to give optimal image quality by automatically selecting Wp, target/filter and mAs according to the thickness and density of the breast. The Medical Physics group of Biomedical Technology Services (BTS) has conducted an investigation into the optimal use of the AOP modes for the GE Senographe 800T and GE Senographe DMR mammography units located in several BreastScreen Queensland (BSQ) clinics. Variation of image quality and dose using the three AOP modes were studied. The planned outcome is to develop a recommendation for the optimal use of AOP modes based on various breast thickness and composition. Both GE Senographe 800T and GE Senographe DMR have 3 AOP mode selections: CNT (contrast), STD (standard) and Dose. Various thickness of perspex ranging from 2cm to 8cm was compressed for each mode to determine the selection of kVp, target/filter and mAs for each apparatus. Image quality was evaluated using a Tor[Mam] phantom for various thicknesses in each AOP mode. The scoring system implemented for image quality was that recommended by Leeds X-ray Imaging (Lxi) where a numerical scale from O to 3 is used to denote the level of visibility of details perceived in the phantom image. Results confirmed that mean glandular dose (MGD) increases with breast thickness. Increasing image contrast will increase dose to breast due to lower energy radiation spectrum used. The GE Senographe DMR has the advantage of utilising a Rhodium target thus giving a lower MGD than the GE Senographe 800T at thickness above 4cm. Film image quality decreases with increasing thickness of perspex. A breast thickness of 2cm yields similar image quality in all 3 AOP modes as the selected kVp value and target filter (Mo/Mo) was similar. There was no significant difference in image quality for the GE Senographe DMR apparatus between 2cm and 4cm for all

  10. Development of Test Protocols for International Space Station Particulate Filters

    Science.gov (United States)

    Vijayakumar, R.; Green, Robert D.; Agui, Juan H.

    2015-01-01

    Air quality control on the International Space Station (ISS) is a vital requirement for maintaining a clean environment for the crew and the hardware. This becomes a serious challenge in pressurized space compartments since no outside air ventilation is possible, and a larger particulate load is imposed on the filtration system due to lack of gravitational settling. The ISS Environmental Control and Life Support System (ECLSS) uses a filtration system that has been in use for over 14 years and has proven to meet this challenge. The heart of this system is a traditional High-Efficiency Particulate Air (HEPA) filter configured to interface with the rest of the life support elements and provide effective cabin filtration. The filter element for this system has a non-standard cross-section with a length-to-width ratio (LW) of 6.6. A filter test setup was designed and built to meet industry testing standards. A CFD analysis was performed to initially determine the optimal duct geometry and flow configuration. Both a screen and flow straighter were added to the test duct design to improve flow uniformity and face velocity profiles were subsequently measured to confirm. Flow quality and aerosol mixing assessments show that the duct flow is satisfactory for the intended leak testing. Preliminary leak testing was performed on two different ISS filters, one with known perforations and one with limited use, and results confirmed that the testing methods and photometer instrument are sensitive enough to detect and locate compromised sections of an ISS BFE.Given the engineering constraints in designing spacecraft life support systems, it is anticipated that non-industry standard filters will be required in future designs. This work is focused on developing test protocols for testing the ISS BFE filters, but the methodology is general enough to be extended to other present and future spacecraft filters. These techniques for characterizing the test duct and perform leak testing

  11. Parallel power electronics filters in three-phase four-wire systems principle, control and design

    CERN Document Server

    Wong, Man-Chung; Lam, Chi-Seng

    2016-01-01

    This book describes parallel power electronic filters for 3-phase 4-wire systems, focusing on the control, design and system operation. It presents the basics of power-electronics techniques applied in power systems as well as the advanced techniques in controlling, implementing and designing parallel power electronics converters. The power-quality compensation has been achieved using active filters and hybrid filters, and circuit models, control principles and operational practice problems have been verified by principle study, simulation and experimental results. The state-of-the-art research findings were mainly developed by a team at the University of Macau. Offering background information and related novel techniques, this book is a valuable resource for electrical engineers and researchers wanting to work on energy saving using power-quality compensators or renewable energy power electronics systems. .

  12. Influence of size, shape, and flexibility on bacterial passage through micropore membrane filters.

    Science.gov (United States)

    Wang, Yingying; Hammes, Frederik; Düggelin, Marcel; Egli, Thomas

    2008-09-01

    Sterilization of fluids by means of microfiltration is commonly applied in research laboratories as well as in pharmaceutical and industrial processes. Sterile micropore filters are subject to microbiological validation, where Brevundimonas diminuta is used as a standard test organism. However, several recent reports on the ubiquitous presence of filterable bacteria in aquatic environments have cast doubt on the accuracy and validity of the standard filter-testing method. Six different bacterial species of various sizes and shapes (Hylemonella gracilis, Escherichia coli, Sphingopyxis alaskensis, Vibrio cholerae, Legionella pneumophila, and B. diminuta) were tested for their filterability through sterile micropore filters. In all cases, the slender spirillum-shaped Hylemonella gracilis cells showed a superior ability to pass through sterile membrane filters. Our results provide solid evidence that the overall shape (including flexibility), instead of biovolume, is the determining factor for the filterability of bacteria, whereas cultivation conditions also play a crucial role. Furthermore, the filtration volume has a more important effect on the passage percentage in comparison with other technical variables tested (including flux and filter material). Based on our findings, we recommend a re-evaluation of the grading system for sterile filters, and suggest that the species Hylemonella should be considered as an alternative filter-testing organism for the quality assessment of micropore filters.

  13. Audit filters for improving processes of care and clinical outcomes in trauma systems.

    Science.gov (United States)

    Evans, Christopher; Howes, Daniel; Pickett, William; Dagnone, Luigi

    2009-10-07

    Traumatic injuries represent a considerable public health burden with significant personal and societal costs. The care of the severely injured patient in a trauma system progresses along a continuum that includes numerous interventions being provided by a multidisciplinary group of healthcare personnel. Despite the recent emphasis on quality of care in medicine, there has been little research to direct trauma clinicians and administrators on how optimally to monitor and improve upon the quality of care delivered within a trauma system. Audit filters are one mechanism for improving quality of care and are defined as specific clinical processes or outcomes of care that, when they occur, represent unfavorable deviations from an established norm and which prompt review and feedback. Although audit filters are widely utilized for performance improvement in trauma systems they have not been subjected to systematic review of their effectiveness. To determine the effectiveness of using audit filters for improving processes of care and clinical outcomes in trauma systems. Our search strategy included an electronic search of the Cochrane Injuries Group Specialized Register, the Cochrane EPOC Group Specialized Register, CENTRAL (The Cochrane Library 2008, Issue 4), MEDLINE, PubMed, EMBASE, CINAHL, and ISI Web of Science: (SCI-EXPANDED and CPCI-S). We handsearched the Journal of Trauma, Injury, Annals of Emergency Medicine, Academic Emergency Medicine, and Injury Prevention. We searched two clinical trial registries: 1) The World Health Organization International Clinical Trials Registry Platform and, 2) Clinical Trials.gov. We also contacted content experts for further articles. The most recent electronic search was completed in December 2008 and the handsearch was completed up to February 2009. We searched for randomized controlled trials, controlled clinical trials, controlled before-and-after studies, and interrupted time series studies that used audit filters as an

  14. Neutron Transmission of Single-crystal Sapphire Filters

    Science.gov (United States)

    Adib, M.; Kilany, M.; Habib, N.; Fathallah, M.

    2005-05-01

    An additive formula is given that permits the calculation of the nuclear capture, thermal diffuse and Bragg scattering cross-sections as a function of sapphire temperature and crystal parameters. We have developed a computer program that allows calculations of the thermal neutron transmission for the sapphire rhombohedral structure and its equivalent trigonal structure. The calculated total cross-section values and effective attenuation coefficient for single-crystalline sapphire at different temperatures are compared with measured values. Overall agreement is indicated between the formula and experimental data. We discuss the use of sapphire single crystal as a thermal neutron filter in terms of the optimum cystal thickness, mosaic spread, temperature, cutting plane and tuning for efficient transmission of thermal-reactor neutrons.

  15. An improved ultra-wideband bandpass filter design using split ring resonator with coupled microstrip line

    Science.gov (United States)

    Umeshkumar, Dubey Suhmita; Kumar, Manish

    2018-04-01

    This paper incorporates an improved design of Ultra Wideband Bandpass filter by using split ring resonators (SRR) along with the coupled microstrip lines. The use of split ring resonators and shunt step impedance open circuit stub enhances the stability due to transmission zeroes at the ends. The designing of filter and simulation of parameters is carried out using Ansoft's HFSS 13.0 software on RT/Duroid 6002 as a substrate with dielectric constant of 2.94. The design utilizes a frequency band from 22GHz to 29GHz. This band is reserved for Automotive Radar system and sensors as per FCC specifications. The proposed design demonstrates insertion loss less than 0.6dB and return loss better than 12dB at mid frequency i.e. 24.4GHz. The reflection coefficient shows high stability of about 12.47dB at mid frequency. The fractional bandwidth of the proposed filter is about 28.7% and size of filter design is small due to thickness of 0.127mm.

  16. Braile vena cava filter and greenfield filter in terms of centralization.

    Science.gov (United States)

    de Godoy, José Maria Pereira; Menezes da Silva, Adinaldo A; Reis, Luis Fernando; Miquelin, Daniel; Torati, José Luis Simon

    2013-01-01

    The aim of this study was to evaluate complications experienced during implantation of the Braile Vena Cava filter (VCF) and the efficacy of the centralization mechanism of the filter. This retrospective cohort study evaluated all Braile Biomédica VCFs implanted from 2004 to 2009 in Hospital de Base Medicine School in São José do Rio Preto, Brazil. Of particular concern was the filter's symmetry during implantation and complications experienced during the procedure. All the angiographic examinations performed during the implantation of the filters were analyzed in respect to the following parameters: migration of the filter, non-opening or difficulties in the implantation and centralization of the filter. A total of 112 Braile CVFs were implanted and there were no reports of filter opening difficulties or in respect to migration. Asymmetry was observed in 1/112 (0.9%) cases. A statistically significant difference was seen on comparing historical data on decentralization of the Greenfield filter with the data of this study. The Braile Biomédico filter is an evolution of the Greenfield filter providing improved embolus capture and better implantation symmetry.

  17. Efficacy of photobiomodulation therapy on masseter thickness and oral health-related quality of life in children with spastic cerebral palsy.

    Science.gov (United States)

    Santos, Maria Teresa Botti Rodrigues; Nascimento, Karla Santos; Carazzato, Simone; Barros, Alina Oliveira; Mendes, Fausto Medeiros; Diniz, Michele Baffi

    2017-08-01

    The study aimed to evaluate the efficacy of photobiomodulation therapy (PBMT) on bilateral masseter muscle thickness and amplitude of mouth opening in children with spastic cerebral palsy (CP), and the impact on their oral health-related quality of life (OHRQOL). Three groups were included: experimental CP group (EG: n = 26 with oral complaints), positive control CP group (PCG: n = 26 without complaints), and negative control group (NCG: n = 26 without CP). In the EG, the masseter muscles on both sides were irradiated with an infrared low-level Ga-Al-As laser (λ = 808 ± 3 nm, 120 mW) using a 3 J/cm 2 energy dose per site, with a 20 s exposure time per site (spot area: 4 mm 2 ; irradiance: 3 W/cm 2 ; energy delivery per point: 2.4 J) six times over six consecutive weeks. Masseter thickness, assessed through ultrasonography, and the amplitude of mouth opening were measured in the EG before and after six applications of PBMT and once in the PCG and NCG. The Parental-Caregiver Perception Questionnaire (P-CPQ) was used to evaluate OHRQOL. ANOVA, chi-square, t tests, and multilevel linear regression were used for statistical analysis. In the EG, the study results revealed average increments of 0.77 (0.08) millimeter in masseter thickness (P < 0.05) and 7.39 (0.58) millimeter for mouth opening (P < 0.05) and reduction in all P-CPQ domains (P < 0.001), except for social well-being. The six applications of PBMT increased masseter thickness and mouth opening amplitude and reduced the impact of spastic CP on OHRQOL.

  18. Recent progress in plasmonic colour filters for image sensor and multispectral applications

    Science.gov (United States)

    Pinton, Nadia; Grant, James; Choubey, Bhaskar; Cumming, David; Collins, Steve

    2016-04-01

    Using nanostructured thin metal films as colour filters offers several important advantages, in particular high tunability across the entire visible spectrum and some of the infrared region, and also compatibility with conventional CMOS processes. Since 2003, the field of plasmonic colour filters has evolved rapidly and several different designs and materials, or combination of materials, have been proposed and studied. In this paper we present a simulation study for a single- step lithographically patterned multilayer structure able to provide competitive transmission efficiencies above 40% and contemporary FWHM of the order of 30 nm across the visible spectrum. The total thickness of the proposed filters is less than 200 nm and is constant for every wavelength, unlike e.g. resonant cavity-based filters such as Fabry-Perot that require a variable stack of several layers according to the working frequency, and their passband characteristics are entirely controlled by changing the lithographic pattern. It will also be shown that a key to obtaining narrow-band optical response lies in the dielectric environment of a nanostructure and that it is not necessary to have a symmetric structure to ensure good coupling between the SPPs at the top and bottom interfaces. Moreover, an analytical method to evaluate the periodicity, given a specific structure and a desirable working wavelength, will be proposed and its accuracy demonstrated. This method conveniently eliminate the need to optimize the design of a filter numerically, i.e. by running several time-consuming simulations with different periodicities.

  19. The Use of Innovative Ceramic-Carbon Bonded Filters Used for Filtration of Liquid Alloys and Evaluation of the Filtration Efficiency

    Directory of Open Access Journals (Sweden)

    Karwiński A.

    2014-08-01

    Full Text Available Extremely intense development of civilization requires from foundry casting technologies very high quality and not expensive castings. In the foundries, there are many treatments that allow increasing of the final properties of produced castings such as refining, modification, heat treatment, etc. One of the methods of increasing the quality of the casting by removing inclusions from the liquid alloy is filtration. The use of ceramic-carbon foam filters in filtration process is still analysed phenomenon that allows improving the final properties of castings. A modern method of research, testing and synthesis of innovative chemical compositions allows improving the properties of such filters. In the paper the evaluation of application properties of developed ceramic-carbon bonded foam filters is presented. The quality of the foam filters is evaluated by Computer Tomography and foundry trials in pouring of liquid metal in test molds. Additionally computer simulations were made to visualize the flow characteristics in the foam filter. The analysed filters are the result of the research work of Foundry Research Institute and the Institute of Ceramics and Building Materials, Refractory Materials Department in Gliwice.

  20. Nondestructive web thickness measurement of micro-drills with an integrated laser inspection system

    Science.gov (United States)

    Chuang, Shui-Fa; Chen, Yen-Chung; Chang, Wen-Tung; Lin, Ching-Chih; Tarng, Yeong-Shin

    2010-09-01

    Nowadays, the electric and semiconductor industries use numerous micro-drills to machine micro-holes in printed circuit boards. The measurement of web thickness of micro-drills, a key parameter of micro-drill geometry influencing drill rigidity and chip-removal ability, is quite important to ensure quality control. Traditionally, inefficiently destructive measuring method is adopted by inspectors. To improve quality and efficiency of the web thickness measuring tasks, a nondestructive measuring method is required. In this paper, based on the laser micro-gauge (LMG) and laser confocal displacement meter (LCDM) techniques, a nondestructive measuring principle of web thickness of micro-drills is introduced. An integrated laser inspection system, mainly consisting of a LMG, a LCDM and a two-axis-driven micro-drill fixture device, was developed. Experiments meant to inspect web thickness of micro-drill samples with a nominal diameter of 0.25 mm were conducted to test the feasibility of the developed laser inspection system. The experimental results showed that the web thickness measurement could achieve an estimated repeatability of ± 1.6 μm and a worst repeatability of ± 7.5 μm. The developed laser inspection system, combined with the nondestructive measuring principle, was able to undertake the web thickness measuring tasks for certain micro-drills.