WorldWideScience

Sample records for thermoluminescent detectors desenvolvimento

  1. A study of the thermoluminescent properties of CVD diamond detectors

    International Nuclear Information System (INIS)

    Marczewska, B.; Bilski, P.; Olko, P.; Rebisz, M.; Nesladek, M.; Waligorski, M.P.R.

    2002-01-01

    A batch of 20 diamond detectors obtained by the chemical vapour deposition (CVD) method at the Institute for Materials Research at the Limburg University, Belgium, was investigated with respect to their thermoluminescent (TL) properties. The investigated detectors demonstrate TL sensitivity similar to that of the standard LiF:Mg, Ti (MTS) thermoluminescent detectors, lack of fading after two weeks from irradiation and apparent linearity of dose response. In spite of the persistent fluctuation of individual detector sensitivity observed in this batch, a new annealing procedure improved the stability of the TL signal. It has been concluded that 1 h annealing at 350 C assures the highest reproducibility for this set of detectors. A 30% discrepancy of the value of the TL signal between individual detectors from the batch may be caused by non-uniform distribution of dopants in the volume of the CVD diamond. A prototype of a planar TL reader equipped with a CCD camera was employed in this investigation. (Abstract Copyright [2002], Wiley Periodicals, Inc.)

  2. Study on the fast neutron sensitivity of thermoluminescent detectors

    International Nuclear Information System (INIS)

    Szabo, P.P.; Palfalvi, J.

    1984-03-01

    Fast neutron (14.7 MeV) sensitivity of several thermoluminescent detectors was determined. The investigated detectors were MTS-N type pellets (made in Poland) used routinely in the authors' institute for personnel dosimetry, 7 LiF powder used for accident dosimetry, CaSO 4 :Dy and CaSO 4 :Tm powders (made in Hungary) used for enviromental monitoring and space dosimetry. Both free-in-air and on-phantom irradiations were performed. The new results are compared with responses calculated and measured earlier. (author)

  3. The influence of temperature and humidity on the stability of the response of different thermoluminescent detectors

    International Nuclear Information System (INIS)

    Rosa, L.A.R. da

    1989-01-01

    Fading results are presented for thermoluminescent detectors for temperatures of 20, 35 and 50 0 C and for relative humidities of 50 and 90% during storage periods of up to 30 days. The thermoluminescent detectors investigated were LiF:Mg,Ti(TLD-100 and TLD-700), CaF 2 :Dy(TLD-200) and Li 2 B 4 O 7 :Mn,Si. These detectors are very commonly used in personnel monitoring. (author)

  4. Comparative measurements of soil gas radon concentration using thermoluminescent and track detectors

    Czech Academy of Sciences Publication Activity Database

    Turek, Karel; Gelev, M.; Dimov, I.

    2004-01-01

    Roč. 38, spec. iss. (2004), s. 843-846 ISSN 1350-4487 Institutional research plan: CEZ:AV0Z1048901 Keywords : soil gas * radon concentration * thermoluminescent detectors Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 0.664, year: 2004

  5. Investigations of doses on board commercial passenger aircraft using CR-39 and thermoluminescent detectors

    Czech Academy of Sciences Publication Activity Database

    Horwacik, T.; Bilski, P.; Olko, P.; Spurný, František; Turek, Karel

    2004-01-01

    Roč. 110, 1-4 (2004), s. 377-380 ISSN 0144-8420 Grant - others:EC project(XE) FIGM-CT2000-00068 Institutional research plan: CEZ:AV0Z1048901 Keywords : Aircrew * thermoluminescent detectors * environmental measurements Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 0.617, year: 2003

  6. In vivo dosimetry using thermoluminescent detector in cancer therapy of head and neck

    International Nuclear Information System (INIS)

    Viegas, Claudio C.B.; Batista, D.V.; Campos, A.M.; Lopes, R.T.

    2002-01-01

    The viability and implementation of a routine in vivo dosimetry, using thermoluminescent dosemeters (TLD), at the radiotherapy section of the National Institute of Cancer in Brazil, in the case of head and neck treatment is shown. In order to reach that aim, the characteristics of the response of the LiF:Mg;Ti (TLD-100) thermoluminescent detectors in powder form were determined. The performed of this detector for in vivo dosimetry was testes using an RANDO Alderson anthropomorphic phantom and, once their adequability proved for the kind of measurements proposed , it was used for dose assessment in the case of tumour treatments in the head and neck regions, for Cobalt-60 irradiations. (author)

  7. Treatment verification and in vivo dosimetry for total body irradiation using thermoluminescent and semiconductor detectors

    International Nuclear Information System (INIS)

    Oliveira, F.F.; Amaral, L.L.; Costa, A.M.; Netto, T.G.

    2014-01-01

    The objective of this work is the characterization of thermoluminescent and semiconductor detectors and their applications in treatment verification and in vivo dosimetry for total body irradiation (TBI) technique. Dose measurements of TBI treatment simulation performed with thermoluminescent detectors inserted in the holes of a “Rando anthropomorphic phantom” showed agreement with the prescribed dose. For regions of the upper and lower chest where thermoluminescent detectors received higher doses it was recommended the use of compensating dose in clinic. The results of in vivo entrance dose measurements for three patients are presented. The maximum percentual deviation between the measurements and the prescribed dose was 3.6%, which is consistent with the action level recommended by the International Commission on Radiation Units and Measurements (ICRU), i.e., ±5%. The present work to test the applicability of a thermoluminescent dosimetric system and of a semiconductor dosimetric system for performing treatment verification and in vivo dose measurements in TBI techniques demonstrated the value of these methods and the applicability as a part of a quality assurance program in TBI treatments. - Highlights: • Characterization of a semiconductor dosimetric system. • Characterization of a thermoluminescent dosimetric system. • Application of the TLDs for treatment verification in total body irradiation treatments. • Application of semiconductor detectors for in vivo dosimetry in total body irradiation treatments. • Implementation of in vivo dosimetry as a part of a quality assurance program in radiotherapy

  8. Cosmic radiation monitoring at low-Earth orbit by means of thermoluminescence and plastic nuclear track detectors

    Czech Academy of Sciences Publication Activity Database

    Ambrožová, Iva; Pachnerová Brabcová, Kateřina; Kubančák, Ján; Šlegl, Jakub; Tolochek, R. V.; Ivanova, O. A.; Shurshakov, V. A.

    2017-01-01

    Roč. 106, č. 12 (2017), s. 262-266 ISSN 1350-4487 R&D Projects: GA ČR GJ15-16622Y Institutional support: RVO:61389005 Keywords : BION-M1 * cosmic radiation * low earth orbit * passive detector * thermoluminescent detector * plastic nuclear track detector Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders OBOR OECD: Nuclear physics Impact factor: 1.442, year: 2016

  9. Dosimetric study of thermoluminescent detectors in clinical photon beams using liquid water and PMMA phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Matsushima, Luciana C., E-mail: lmatsushima@ipen.br [Gerencia de Metrologia das Radiacoes (GMR) - Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Av. Prof. Lineu Prestes, 2242, Cidade Universitaria, CEP: 05508-000, Sao Paulo, SP (Brazil); Veneziani, Glauco R. [Gerencia de Metrologia das Radiacoes (GMR) - Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Av. Prof. Lineu Prestes, 2242, Cidade Universitaria, CEP: 05508-000, Sao Paulo, SP (Brazil); Sakuraba, Roberto K. [Gerencia de Metrologia das Radiacoes (GMR) - Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Av. Prof. Lineu Prestes, 2242, Cidade Universitaria, CEP: 05508-000, Sao Paulo, SP (Brazil); Sociedade Beneficente Israelita Brasileira - Hospital Albert Einstein (HAE), Avenida Albert Einstein, 665, Morumbi, CEP: 05652-000, Sao Paulo, SP (Brazil); Cruz, Jose C. da [Sociedade Beneficente Israelita Brasileira - Hospital Albert Einstein (HAE), Avenida Albert Einstein, 665, Morumbi, CEP: 05652-000, Sao Paulo, SP (Brazil)

    2012-07-15

    The purpose of this study was the dosimetric evaluation of thermoluminescent detectors of calcium sulphate doped with dysprosium (CaSO{sub 4}:Dy) produced by IPEN compared to the TL response of lithium fluoride doped with magnesium and titanium (LiF:Mg,Ti) dosimeters and microdosimeters produced by Harshaw Chemical Company to clinical photon beams dosimetry (6 and 15 MV) using liquid water and PMMA phantoms. - Highlights: Black-Right-Pointing-Pointer Dosimetric study of thermoluminescent detectors of CaSO{sub 4}:Dy, LiF:Mg,Ti and {mu}LiF:Mg,Ti. Black-Right-Pointing-Pointer Clinical (6 and 15 MV) photon beams dosimetry using liquid water and PMMA phantom. Black-Right-Pointing-Pointer Linear behavior to the dose range (0.1 to 5 Gy). Black-Right-Pointing-Pointer TL response reproducibility better than {+-}4.34%. Black-Right-Pointing-Pointer CaSO{sub 4}:Dy represent a cheaper alternative to the TLD-100.

  10. In vivo dosimetry with semiconductor and thermoluminescent detectors applied to head and neck cancer treatment

    International Nuclear Information System (INIS)

    Viegas, Claudio Castelo Branco

    2003-03-01

    In vivo dosimetry in radiotherapy, i. e, the assessment of the doses received by patients during their treatments, permits a verification of the therapy quality. A routine of in vivo dosimetry is, undoubtedly, a direct benefit for the patient. Unfortunately, in Brazil and in Latin America this procedure is still a privilege for only a few patients. This routine is of common application only in developed countries. The aim of this work is to show the viability and implementation of a routine in vivo dosimetry, using diodes semiconductors and thermoluminescent dosimeters (TLD), at the radiotherapy section of the National Institute of Cancer in Brazil, in the case of head and neck cancer treatment. In order to reach that aim, the characteristics of the response of diodes ISORAD-p and LiF:Mg;Ti (TLD-100) thermoluminescent detectors in powder form were determined. The performance of those detectors for in vivo dosimetry was tested using an RANDO Alderson anthropomorfic phantom and, once their adequacy proved for the kind of measurements proposed, they were used for dose assessment in the case of tumour treatments in the head and neck regions, for Cobalt-60 irradiations. (author)

  11. Measurement of the gamma dose rate distribution in a spent fuel assembly with a thermoluminescent detector

    International Nuclear Information System (INIS)

    Ohno, A.; Matsuura, S.

    1980-01-01

    Thermoluminescent detectors (TLDs) were applied to measurements of gamma dose rates and their distributions in spent fuel assemblies irradiated in a boiling water reactor, the Japan Power Demonstration Reactor (JPDR). Materials used for the TLD were Mg 2 SiO 4 :Tb and LiF. Feasibility of the technique was confirmed by an on-site measurement in a spent fuel pond of the JPDR. The highest gamma dose rate calibrated to a 60 Co gamma field was 4 x 10 3 R/h in the measured positions in a spent fuel assembly, with an average burnup of 5639 MWd/MTM and a cooling time of 8 yr. Reliability of the measurement by means of a TLD was tested via duplicate measurements on a fuel assembly. In the fields of nuclear safeguards and fuel management, application of TLDs will be effective in obtaining inside information of a spent fuel assembly nondestructively

  12. Characterisation of an isotopic neutron source: A comparison of conventional neutron detectors and micro-silica glass bead thermoluminescent detectors

    Science.gov (United States)

    Abubakar, Y. M.; Taggart, M. P.; Alsubaie, A.; Alanazi, A.; Alyahyawi, A.; Lohstroh, A.; Shutt, A.; Jafari, S. M.; Bradley, D. A.

    2017-11-01

    As a result of their thermoluminescent response, low cost commercial glass beads have been demonstrated to offer potential use as radiation dosimeters, providing capability in sensing different types of ionising radiation. With a linear response over a large range of dose and spatial resolution that allows measurements down to the order of 1 mm, their performance renders them of interest in situations in which sensitivity, dynamic range, and fine spatial resolution are called for. In the present work, the suitability of glass beads for characterisation of an Americium-Beryllium (241AmBe) neutron source has been assessed. Direct comparison has been made using conventional 3He and boron tri-fluoride neutron detectors as well as Monte Carlo simulation. Good agreement is obtained between the glass beads and gas detectors in terms of general reduction of count rate with distance. Furthermore, the glass beads demonstrate exceptional spatial resolution, leading to the observation of fine detail in the plot of dose versus distance from source. Fine resolution peaks arising in the measured plots, also present in simulations, are interesting features which based on our best knowledge have previously not been reported. The features are reproduced in both experiment and simulation but we do not have a firm reason for their origin. Of greater clarity is that the glass beads have considerable potential for use in high spatial resolution neutron field characterisation, subject to the availability of a suitable automated TLD reader.

  13. Improved processes in therapy dosimetry with solid LiF thermoluminescent detectors

    International Nuclear Information System (INIS)

    Toivonen, M.

    1991-08-01

    The thesis presents criteria for thermoluminescence dosimetry systems suitable for precision measurements and, moreover, a detailed examination of the sources of systematic and random error. Instructions are given for annealing processes, calibration procedures, quality control, and operational rules, which are necessary in modem TLD. The performances of some principally different systems are compared. The old LiF-powder-based TLD system, with an overall uncertainty of measurement of about 1.6 percent for ten repeated readouts and for irradiations under calibration conditions with Co-60, is still the best but a comparable, although slightly lower, accuracy of about 1.7 percent can be reached more conveniently with solid LiF detectors. In measurements where absolute system calibration is not of interest (i.e., in depth-dose curve measurements, etc.), the advantages of the simple powder-based system are even more concrete. An integrated TLD process is presented for progressive utilization of automation in precision measurements. The sources of random error and unknown systematic error in current readout instruments are examined. Mechanical tolerances in critical parts of the readout instruments are thought to be the reason why the method of heating with hot gas has not been superior with respect to the precision of measurements, in spite of the excellent repeatability of the glow curve shape observed for successive readouts

  14. Energy dependence of new thermoluminescent detectors in terms of H{sub p}{sup 10} values

    Energy Technology Data Exchange (ETDEWEB)

    Miljanic, S.; Knezevic, C.; Stuhec, M.; Ranogajec-Komor, M.; Krpan, K.; Vekic, B

    2003-07-01

    The aim of this work was to determine energy dependence characteristics in terms of values of the personal dose equivalent, H{sub p}(10). The following types of thermoluminescent detectors (TLDs) were investigated: (a) two new types based on lithium borate Li{sub 2}B{sub 4}0{sub 7}:Cu,In and Li{sub 2}B{sub 407}:Cu,In,Ag; (b) two types based on the highly sensitive material LiF:Mg,Cu,P, TLD-700H and GR 200A; (c) two well-known types of LiF:Mg,Ti detectors, TLD-100 and TLD-700 and (d) highly sensitive Al{sub 2}0{sub 3}:C detectors. TLDs previously calibrated with {sup 137}Cs gamma rays were simultaneously irradiated with X ray beams in the range of mean energies between 33 and 116 keV. The irradiations were performed with detectors in polymethyl methacrylate (PMMA) holders placed on a 30 cm x 30 cm x 15 cm water phantom with PMMA walls (ISO phantom). Measured energy responses were compared with calculated data for H{sub p}(10) values. The results confirmed the satisfactory tissue equivalent characteristics of all investigated TLDs except Al{sub 2}0{sub 3}:C, which (due to its large energy dependence) is suitable for personal dosimetry only with an appropriate filter. (author)

  15. Neutron Activation and Thermoluminescent Detector Responses to a Bare Pulse of the CEA Valduc SILENE Critical Assembly

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Thomas Martin [ORNL; Isbell, Kimberly McMahan [ORNL; Lee, Yi-kang [French Atomic Energy Commission (CEA), Centre de Saclay, Gif sur Yvette; Gagnier, Emmanuel [French Atomic Energy Commission (CEA), Centre de Saclay, Gif sur Yvette; Authier, Nicolas [French Atomic Energy Commission (CEA), Centre de Valduc, Is-sur-Tille; Piot, Jerome [French Atomic Energy Commission (CEA), Centre de Valduc, Is-sur-Tille; Jacquet, Xavier [French Atomic Energy Commission (CEA), Centre de Valduc, Is-sur-Tille; Rousseau, Guillaume [French Atomic Energy Commission (CEA), Centre de Valduc, Is-sur-Tille; Reynolds, Kevin H. [Y-12 National Security Complex

    2016-09-01

    This benchmark experiment was conducted as a joint venture between the US Department of Energy (DOE) and the French Commissariat à l'Energie Atomique (CEA). Staff at the Oak Ridge National Laboratory (ORNL) in the US and the Centre de Valduc in France planned this experiment. The experiment was conducted on October 11, 2010 in the SILENE critical assembly facility at Valduc. Several other organizations contributed to this experiment and the subsequent evaluation, including CEA Saclay, Lawrence Livermore National Laboratory (LLNL), the Y-12 National Security Complex (NSC), Babcock International Group in the United Kingdom, and Los Alamos National Laboratory (LANL). The goal of this experiment was to measure neutron activation and thermoluminescent dosimeter (TLD) doses from a source similar to a fissile solution critical excursion. The resulting benchmark can be used for validation of computer codes and nuclear data libraries as required when performing analysis of criticality accident alarm systems (CAASs). A secondary goal of this experiment was to qualitatively test performance of two CAAS detectors similar to those currently and formerly in use in some US DOE facilities. The detectors tested were the CIDAS MkX and the Rocky Flats NCD-91. These detectors were being evaluated to determine whether they would alarm, so they were not expected to generate benchmark quality data.

  16. From nGy to MGy: new dosimetry with LiF:Mg,Cu,P thermoluminescence detectors

    Energy Technology Data Exchange (ETDEWEB)

    Obryk, Barbara [Institute of Nuclear Physics PAN (IFJ), Krakow (Poland)

    2012-07-01

    Full text: Thermoluminescence (TL) detectors are an established method for passive dose measurement. Over the last several years LiF:Mg,Cu,P (MCP) detectors have been widely used in modern TL dosimetry due to their very high sensitivity and simple signal-dose relation which enables measurements of radiation doses from tens of nanograys up to a few kilograys when the total saturation of the signal of the main dosimetric peak (at 220 deg C) occurs. Only recently we have discovered at the IFJ their quite unexpected properties at high and ultra-high doses. Significant changes of the glow-curve shape occur for doses higher than a few kilograys and the most important finding is that a new, intensive peak appears for doses above 20 kGy. This peak, denoted as peak 'B', is well separated from the rest of the glow-curve and located at temperatures exceeding 400 deg C; however, its position shifts towards higher temperatures with increasing dose, what is not predicted by standard TL models. After the discovery of the unexpected behaviour of LiF:Mg,Cu,P detectors at high doses, comprehensive measurements of their response to high doses of specific radiation types: i.e. photons, electrons, protons and neutrons were completed. The results confirmed the high-dose behaviour of these detectors. A parameter called the 'ultra- high temperature ratio' (UHTR) was defined in order to quantify the observed changes of the LiF:Mg,Cu,P glow-curve shape at very high doses and very high temperatures, which enables determining an absorbed dose in the range from 1 kGy to 1MGy. The newly developed method for ultra-high dose range monitoring with a single MCP detector, which is capable of covering 12 orders of magnitude of doses, is a very promising tool for accident dosimetry as it does not require any dose-range prediction. From many possible applications of this method, an area monitoring around large nuclear installations is of particular importance as this method is a

  17. TELDE thermoluminescent dosimetry system

    International Nuclear Information System (INIS)

    Shvarts, K.K.; Nemiro, E.A.; Bichev, V.R.; Gotlib, V.I.; Grant, Z.A.; Grube, M.M.; Gubatova, D.J.

    1981-01-01

    The TELDE dosimetric set designed for measurement of x- and γ- rays doses with energy more than 10 keV is described. The set consists of thermoluminescent detectors from LiF (Ca, Mg, Ti). The detectors are polycrystalline pellets with diameter 3.5+-0.3 mm and thickness 2+-0.2 mm. In the thermoluminescence detectors both the peak and integral measurement methods are realized. Apart from this the TELDE set comprises the electron unit for the pre-irradiation thermal treatment of detectors, special bones for detectors storage and transportation, devices for their package in polyethelene film and containers to wear the detectors. The TELDE set allows to perform measurements on people or animals in radiobiological experiments as well as in water, solid or porous phantoms [ru

  18. Characterization of the thermoluminescent detectors LiF:Mg,Cu,P. Environmental dosimetry applications

    International Nuclear Information System (INIS)

    Ciocci Brazzano, Ligia; Gregori, Beatriz N.; Papadopulos, Susana B.; Carelli, Jorge L.

    2005-01-01

    Studies on thermal-luminescent properties of the LiF:Mg detectors, Cu, P enrichment with Li-7 (99.93% of Li-7 and 0.07% of Li-6): optimization of the heating profile, loss of information, detection limit and doses and energy responses are presented in this work. Their performance is compared with LiF:Mg detectors, Mg, Ti enriched with Li-7 (99.93% of Li-7 and 0.07% Li-6), which are at present used for environmental dosimetry at the Physics Dosimetry Laboratory of the Nuclear Regulatory Authority [es

  19. The dielectric track and thermoluminescent detectors applied to neutron dosimetry in personnel monitoring

    International Nuclear Information System (INIS)

    Mebhah, D.

    1984-03-01

    The personnal dosimeter for neutron based on the detection of fission fragments from 237 Np and 232 Th by a polycarbonate 10 gm, and lithium fluorite 6 LIF/ 7 LIF, allow to cover an energy spectrum from 0.05 eV to 14 MeV with a easy neutron gamma discrimination. In criticality dosimetry, the energy spectrum of the incident neutrons can be defined by two components: the fast component by E b exp(-ae) with E between 0.1 and 14 MeV, a and b determined by a combination of 237 Np and 232 Th track detector responses, and the epithermal component in 1/E, the thermal component having a minor contribution to the total equivalent dose. We took into account the body influence on the detectors response by introducing effective cross section. The equivalent dose obtained by this dosimeter is 20% overestimated in low doses dosimetry. The interpretation of the detectors responses is based on the definition of a factor and a calibration parameter for each zone in which the spectrum is constant. The knowledge of this parameter for individual dosimeters allows to account for the variations of the conditions of calibration

  20. Thermoluminescent dosimeter

    International Nuclear Information System (INIS)

    Stewart, J.C.

    1981-01-01

    A dosimeter of the type in which two plates of plastics material are bonded together with a layer of thermoluminescent material trapped between is described. The device is made by sprinkling granular thermoluminescent material over areas of a plastics plate which has adhesive on it, removing excess material and then applying a second layer of plastics material over the first layer, and over the thermoluminescent material, and bonding it to complete the dosimeter. (author)

  1. Experimental determination of the photon-energy dependent dose-to-water response of TLD600 and TLD700 (LiF:Mg,Ti) thermoluminescence detectors

    Energy Technology Data Exchange (ETDEWEB)

    Schwahofer, Andrea [Vivantes Clinic Neukoelln, Berlin (Germany). Dept. of Radiation Therapy; German Cancer Research Center, Heidelberg (Germany). Medical Physics in Radiation Therapy; Feist, Harald [Munich Univ. (Germany). Dept. of Radiation Therapy; Georg, Holger [PTW Freiburg (Germany). Calibration Lab.; Haering, Peter; Schlegel, Wolfgang [German Cancer Research Center, Heidelberg (Germany). Medical Physics in Radiation Therapy

    2017-05-01

    The aim of this study has been the experimental determination of the energy dependent dose-to-water response of TLD600 and TLD700 thermoluminescent detectors (Harshaw) in X-ray beams with mean photon energies from about 20 to 200 keV in comparison with {sup 60}Co gamma rays and 6 MV X-rays. Experiments were carried out in collaboration with the German secondary standard laboratory PTW Freiburg. The energy dependent relative responses of TLD600 and TLD700 thermoluminescence detectors were determined at radiation qualities between 30 kV{sub p} and 280 kV{sub p}. The overall uncertainty of the measured values was characterized by standard deviations varying from 1.2 to 3%. The present results agree with previous studies on the energy dependent dose-to-water response of TLD100. As an application example, the results were used to measure doses associated with X-ray imaging in image-guided radiotherapy.

  2. Unraveling thermoluminescence

    CERN Document Server

    Sunta, C M

    2014-01-01

    The book is essentially about the theoretical aspects of thermoluminescence (TL). It is structured and written in a manner which will specially be of interest to the fresh undergraduate students and young researchers planning to take up work in the field of thermoluminescence. It is arranged into seven chapters, starting with the historical growth of the subject of TL and an overview of the luminescence phenomena. A Physical model involving thermally disconnected deep traps is specially described. Using this model expressions are derived for the TL intensity growth curve, the supralinearity fa

  3. In vivo dosimetry with semiconductor and thermoluminescent detectors applied to head and neck cancer treatment; Dosimetria in vivo com uso de detectores semicondutores e termoluminescentes aplicada ao tratamento de cancer de cabeca e pescoco

    Energy Technology Data Exchange (ETDEWEB)

    Viegas, Claudio Castelo Branco

    2003-03-15

    In vivo dosimetry in radiotherapy, i. e, the assessment of the doses received by patients during their treatments, permits a verification of the therapy quality. A routine of in vivo dosimetry is, undoubtedly, a direct benefit for the patient. Unfortunately, in Brazil and in Latin America this procedure is still a privilege for only a few patients. This routine is of common application only in developed countries. The aim of this work is to show the viability and implementation of a routine in vivo dosimetry, using diodes semiconductors and thermoluminescent dosimeters (TLD), at the radiotherapy section of the National Institute of Cancer in Brazil, in the case of head and neck cancer treatment. In order to reach that aim, the characteristics of the response of diodes ISORAD-p and LiF:Mg;Ti (TLD-100) thermoluminescent detectors in powder form were determined. The performance of those detectors for in vivo dosimetry was tested using an RANDO Alderson anthropomorfic phantom and, once their adequacy proved for the kind of measurements proposed, they were used for dose assessment in the case of tumour treatments in the head and neck regions, for Cobalt-60 irradiations. (author)

  4. Method of thermoluminescent measurement of radiation doses from micrograys up to a megagray with a single LiF: Mg,Cu,P detector

    International Nuclear Information System (INIS)

    Obryk, B.; Bilski, P.; Olko, P.

    2011-01-01

    On the basis of the newly discovered behaviour of LiF:Mg,Cu,P detectors at high and ultra-high doses, a new method of thermoluminescence (TL) measurement of radiation doses ranging from micrograys up to a megagray, has been recently developed at the Inst. of Nuclear Physics (IFJ). The method is based on the relationship between the TL signal, integrated in the given temperature range and dose. It is quantified by a parameter called the 'ultra-high temperature ratio'. It has been demonstrated that this new method can measure radiation doses in the range of about 1 μGy to 1 MGy, using a single LiF:Mg,Cu,P detector. This method was recently successfully blindly tested for 10 MeV electrons up to doses of 200 kGy. It can be used for dosimetry in high-energy accelerators, especially in the Large Hadron Collider at CERN, and has great potential for accident dosimetry in particular. (authors)

  5. Radiation detectors

    International Nuclear Information System (INIS)

    2013-01-01

    This sixth chapter presents the operational principles of the radiation detectors; detection using photographic emulsions; thermoluminescent detectors; gas detectors; scintillation detectors; liquid scintillation detectors; detectors using semiconductor materials; calibration of detectors; Bragg-Gray theory; measurement chain and uncertainties associated to measurements

  6. Thermoluminescence and their applications

    International Nuclear Information System (INIS)

    Rodrigues, G.V.

    1986-01-01

    The theory involved in the phenomenon of thermoluminescence emission, the characteristics of the main thermoluminescent phosphorus and some of their applications are presented. Some of the main thermoluminescent dosemeters used in dosimetry are described. (M.C.K.) [pt

  7. Thermoluminescence and applications

    International Nuclear Information System (INIS)

    Rodrigues, G.V.

    1986-01-01

    The theory of thermoluminescent emission, the characteristics of main thermoluminescent phosphorus, and some applications are presented. The main thermoluminescent dosemeters used in dosimetry are related. (M.C.K.)

  8. A method for determining skin dose and the radiation composition in β/γ-mixed fields using 'thick' thermoluminescent detectors

    International Nuclear Information System (INIS)

    Sahre, P.

    1987-01-01

    For determining the skin dose in β/γ-fields of unknown composition normally thin detectors or combined dosimetric systems containing thick detectors have been used up to now. In the paper presented the first attempt to utilize completely the depth dose distribution in a thick, homogeneous TL-detector is proposed and investigated theoretically and experimentally. The method is based on the migration of a temperature front through the detector yielding a special glow curve. The shape of the glow curve and its location depends on the depth dose distribution. The computer aided unfolding of the glow curve using the superposition of standard glow curves is described. The results obtained are the skin dose in a eligible depth (less than the thickness of the detector) and the radiation components at the point of exposition. (author)

  9. Characterisation of sensitive Ge-doped silica flat fibre-based thermoluminescence detectors for high resolution radiotherapy dosimetry

    Science.gov (United States)

    Rahim, A. R. Abdul; Zahaimi, N. A.; Zin, H. M.; Bradley, D. A.; Mahdiraji, G. A.; Rahman, A. T. Abdul

    2017-05-01

    Present study focuses on characterisation of SiO2 optical fibers as a potential thermoluminescence (TL) system for radiation therapy dosimetry. Irradiations were made using 6 MV photon beams from a linear accelerator. Flat SiO2 optical fibers of various dimensions with 8% concentration of germanium doped were used. The dimensions of the flat fibers were 270×60 µm, 360×73 µm, 100×510 µm and 160×750 µm. Flat SiO2 optical fibers were characterised for TL dose response in terms of linearity, sensitivity, fading and reproducibility. The uncertainty measured was ±1 standard error of the mean and the coefficient variation was within ±4%, as required for clinical radiotherapy dosimetry. Results shown a good distribution of TL response measured by flat SiO2 optical fibers with uncertainties less than 4%. Linearity of TL comes out with a coefficient of determination (r2) of each fibers that is better than 99% which resulted in high percentage of confidence level. The loss of TL response due to fading, for photon irradiation at fixed energy and constant dose was found to be (20.4 ± 0.2)% over a post irradiation period of 30 days. The TL fading well, showing rapid loss in the first seven (7) days (17.8 ± 0.2)% followed by a more linear like loss subsequently the following day (3.2 ± 0.2)%. A perfect selection of fibers can enhance the accuracy of radiation dosimeter in order for better determination and measurement of radiation doses with a linear response over wide range therapeutic dose.

  10. Development of multiwire gas detectors for X-rays; Desenvolvimento de detectores a gas multifilares para raios-X

    Energy Technology Data Exchange (ETDEWEB)

    Sales, Eraldo de

    2015-06-01

    This work presents the prototype of a 2D position sensitive gas detector for application in X-ray scattering and diffraction experiments. Starting from a detector initially developed for other applications and will show the required changes on the original concept of this device. The strategy used to determine the necessary adaptations were based on searching in the literature for the overall characteristics of a multi-wire X-ray detector (choice of gas, pressure, window, etc.), the use of simulations, implementation of the changes and finally operational tests. Computational tools were used to calculate the mechanical strength and attenuation of the X-ray photons that helped to determine the most appropriate material for the construction of the entrance window. Detector simulations were built with Garfield software and were used to study the overall properties of the detector, and to determine the optimum parameters for the equipment operation. Typical parameters are the distance between the wires, wire diameter, high voltage to be used, among several other parameters. The results obtained showed that the multi-wire detector concept with the implemented adaptations allowed the detection of X-rays. However, depending on the application, it may be necessary improve the resolution of the equipment, in order to have a better description of the collected data. Several ideas are suggested for this improvement. It is also presented interesting results obtained with a microscopic pattern detector called triple GEM. This device belongs to the Gas Detectors Development group (GDD group) at CERN and was used in my training at this institution. The results showed the potential of the equipment for detection of X-rays. The results and simulations presented in this work, confirmed that the changes in the concept of the original detector permitted it use on X-ray detection applications. Also, it was possible to obtain several indications for further optimization, which may

  11. Thermoluminescence dating

    International Nuclear Information System (INIS)

    Price, D.M.

    1999-01-01

    Thermoluminescence (TL) dating of sediments depends upon the acquisition and long term stable storage of TL energy by crystalline minerals contained within a sedimentary unit. This energy is stored in the form of trapped electrons and quartz sand is the most commonly used mineral employed in the dating process. Prior to the final depositional episode it is necessary that any previously acquired TL is removed by exposure to sunlight. After burial the TL begins to build up again at a rate dependent upon the radiation flux delivered by long-lived isotopes of uranium, thorium and potassium. The presence of rubidium and cosmic radiation generally play a lesser but contributory roll, and the total radiation dose delivered to the TL phosphor is modified by the presence of water. The period since deposition is therefore measured by determining the total amount of stored TL energy, the palaeodose (P), and the rate at which this energy is acquired, the annual radiation dose (ARD). TL dating may be applied to eolian, fluvial, coastal and in some cases, marine sediments. the technique is also successfully applied to volcanic materials and to a certain extent to archeological specimens

  12. Development and characterization of the lead iodide semiconductor detector; Desenvolvimento e caracterizacao do detector semicondutor de iodeto de chumbo

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Icimone Braga de

    2001-07-01

    A methodology for purification and growth of PbI{sub 2} crystal as well as for its characterization as a room temperature radiation detector was developed in this work. Commercial salts were purified using the zone refining method and, for the purified material growth, the Bridgman method was used. To calculate the purification efficiency, studies of the decrease impurities concentrations were made in the salts and in three sections of the materials purified, using the neutron activation analysis technique. The results showed that the impurities segregate preferentially in the ingot final section. A significant decrease of the impurities concentration in function of the purification pass number was observed. The grown crystals presented good crystalline quality according to the results of the X-ray diffraction analysis. To evaluate the crystal as a semiconductor detector, measurements of dark leakage current, resistivity and the response of ({sup 241}Am) alpha particle and ({sup 241}Am, {sup 57}Co, {sup 133}Ba and {sup 137}Cs) gamma rays were carried out. The radiation response is strongly dependent on the crystals purity. The crystals purified with 500 passes exhibited energy resolution of 10% for {sup 241} Am alpha particle and the gamma rays resolution was compatible with the literature. The photosensibility of the PbI{sub 2} crystal found in the wavelength from 400 to 600 nm range suggests an another application at this crystal as a photodetector to be coupled to scintillators. (author)

  13. Thermoluminescence and Thermoluminescent Dosimetry, v. 3

    Energy Technology Data Exchange (ETDEWEB)

    Horowitz, Y.S.

    1984-01-01

    This work is a comprehensive review and guide to the fields of thermoluminescence and thermoluminescent dosimetry. Three up-to-date volumes contain useful tables, illustrations, formulas and references to aid researchers in radiation and nuclear science, dosimetry and solid state physics. Volume III focuses on clinical and archeological-geological applications of TLD. Detailed technical information on TL instrumentation is also included.

  14. Handbook of thermoluminescence

    CERN Document Server

    Furetta, Claudio

    2010-01-01

    This second edition of the Handbook of Thermoluminescence enlarges on all the subjects which were treated in the first edition and adds further arguments, including the theory of thermoluminescent dose measurement, several examples concerning the kinetics parameters determination using various methods such as peak shape, isothermal decay, and so on. A special section is devoted to food irradiation, an important subject at the present time, and to the thermoluminescent characterization of the minerals extracted from the irradiated food. Another new section is devoted to the thermoluminescent ph

  15. Deconvolution study on the glow curve structure of LiF:Mg,Ti and LiF:Mg,Cu,P thermoluminescent detectors exposed to 1H, 4He and 12C ion beams

    Science.gov (United States)

    Parisi, Alessio; Van Hoey, Olivier; Mégret, Patrice; Vanhavere, Filip

    2017-09-01

    Lithium fluoride represents the most frequently used base material for thermoluminescent detectors. The glow curve of these detectors is composed of a series of peaks which intensities strongly depend on the given dose, the type and energy of the impinging radiation, the concentration of dopants in the crystal and the lithium isotopic concentration. In this work, 6LiF:Mg,Ti, 7LiF:Mg,Ti, 6LiF:Mg,Cu,P and 7LiF:Mg,Cu,P detectors were exposed to calibrated hydrogen, helium and carbon ion beams in order to investigate the change of the structure of the different peaks composing the glow curves of these materials and their relative luminescence efficiency. In order to resolve the different peak contributions, computer assisted deconvolution of the glow curve was performed and the used sets of parameters (activation energy E and temperature at peak maximum Tmax) are presented. In the case of LiF:Mg,Ti detectors, the low temperature peaks and the main peak are characterized by a general efficiency decrease with the increase of the LET of the incident particle. No remarkable differences were found between detectors enriched with 6Li or 7Li. On the other hand, differences in the structure of the high temperature peaks between the two lithium isotopic compositions were found and discussed. Regarding LiF:Mg,Cu,P detectors, each peak shows a general monotonously decreasing relative efficiency with the increase of LET. In this case, a similar LET dependence was found between 6Li and 7Li based detectors. Furthermore, unusual efficiencies greater than 1 for the low temperature peaks of LiF:Mg,Cu,P exposed to low LET particle were observed.

  16. Equipment for observing thermoluminescence

    International Nuclear Information System (INIS)

    Sette Camara, Alexandre; Cogneau, Michel; Ristori, Christian; Vargas, Jose Israel

    1971-06-01

    A detailed description is given of an apparatus for investigating thermoluminescence properties. Chopping of the emitted light and subsequent amplification of the electric signal derived led to high stability and sensitivity [fr

  17. Thermoluminescence dating of pottery

    International Nuclear Information System (INIS)

    Higashimura, Takenobu; Ichikawa, Yoneta.

    1978-01-01

    This report is divided into two parts. The first half describes on the history of thermoluminescence dating, and the latter half, the principle and measurement examples. It was in late 1955 that the measurement of radiation dose using thermoluminescence began. The method to thermoluminescence dating was developed when it was found that most natural stones emit the thermoluminescence. About Greek earthen wares, the study of which was presented in 1961 by G. Kennedy of University of California, the dating was able to be made within the standard deviation of 10%. Since then, this dating method progressed rapidly, and a number of laboratories are now forwarding the investigation. In the samples of natural materials, intensity of thermoluminescence I is proportional to natural radiation dose D which has been absorbed by the samples, i.e. I = kD, where k is the susceptibility of thermoluminescence of the samples. Since k is different in each sample, D can be determined by irradiating the sample with β or γ ray of known dose D 0 , measuring its luminescence I 0 , and eliminating k through these two equations, because i 0 = kD 0 . Next, if t is assumed to be the time passed since a pottery was made, D is expressed as Rt, where R is the natural radiation dose per year absorbed by the pottery. Thus t is determined if R is known. The report describes on the method of measuring R. As an example, the results of measurement of the potteries excavated at Iwakura remains, Yorikura, Taishaku-kyo, are listed. Results by 14 C dating are also described for reference. (Wakatsuki, Y.)

  18. Design constrution and testing of a self-powered neutron detector

    International Nuclear Information System (INIS)

    Correa, R.F.

    1987-01-01

    The design, contruction and testing of a self-powered neutron detector (SPN) and associated electronics are described. Several tests were performed giving information about dielectrical properties od detector and cable, gamma spectra induced in the detector through reactor irradiation, detector response as a function of neutron flux, current stability and reproductibility with the neutron flux. The gamma and neutron sensitivities were also evaluated, by means of thermoluminescent dosimeters and gold foils as references. The test results are presented and show that the detector response is reliable. The gamma and neutron sensitivities are in agreement with those found in the available literature. Neverthe less, a ceramic insulated cable should be employed for permanent use in a reactor. The tests were perfomance in a 100 kW TRIGA Mark I reactor at the Centro de Desenvolvimento da Tecnologia Nuclear of NUCLEBRAS,in Belo Horizonte, Brazil. (Author) [pt

  19. Design, construction and testing of a self-powered neutron detector

    International Nuclear Information System (INIS)

    Correa, R.F.

    1987-01-01

    The design, construction and testing of a self-powered neutron detector (SPN) and associated electronics are described. Several tests were performed giving information about dielectrical properties of detector and cable, gamma spectra induced in the detector through reactor irradiation, detector response as a function of neutron flux, current stability and reproductibility with the neutron flux. The gamma and neutron sensitivities were also evaluated, by means of thermoluminescent dosimeters and gold foils as references. The test results are presented and show that the detector response is reliable. The gamma and neutron sensitivities are in agreement with those found in the available literature. Nevertheless, a ceramic insulated cable should be employed for permanent use in a reactor. The tests were performed in a 100 KW TRIGA Mark I reactor at the Centro de Desenvolvimento da Tecnologia Nuclear of NUCLEBRAS, in Belo Horizonte, Brazil. (author) [pt

  20. Thermoluminescence of strontium tetraborate

    International Nuclear Information System (INIS)

    Santiago, M.; Caselli, E.; Lester, M.

    1999-01-01

    The thermoluminescent properties of crystalline strontium tetraborate are reported. Without activators it has an efficiency comparable to that of TLD-700 powder. Its fading after 40 days amount to less than 2%. The isometric plot shows that most of the emitted light is concentrated at wavelengths ranging from 350 to 450 nm, which accounts partially for the high efficiency. (author)

  1. Thermoluminescence dosimetry in Northwest Puerto Rico

    International Nuclear Information System (INIS)

    Block, A.M.; Clements, R.G.; Rosa, L.I.; Santos, F.

    1975-01-01

    In October, 1973, the Puerto Rico Water Resources Authority sought the initiation of studies aimed at determining background radiological characteristics of the northwestern quadrant of Puerto Rico using thermoluminescent dosemeters. Some of the studies were required for supporting data for the environmental report submitted as part of the licensing procedure in the establishment of thermonuclear electric power generation facilities in Barrio Islote, Arecibo, Puerto Rico. Previous studies of radiological characteristics of the area had been made using sodium iodide sensing equipment in an airplane flying at an altitude of 500 ft. The results are expressed in counts per second, and provide useful comparative levels for radioactivity measured with the thermoluminescent detectors. (U.S.)

  2. Evaluation of the relative thermoluminescence efficiency of LiF:Mg,Ti and LiF:Mg,Cu,P TL detectors to low-energy heavy ions

    DEFF Research Database (Denmark)

    Gieszczyk, W.; Bilski, P.; Olko, P.

    2013-01-01

    and xenon ion beams, at energies ranging from 5.0 to 9.3 MeV/n. Supra- and sublinear response was found, for the MTS-N and MCP-N, respectively, similarly as observed for γ-rays. However, the level of nonlinearity of response of studied detectors is strongly reduced by increasing values of the ion ionization...... density (no supralinearity for Xe ions, for MTS-N, within calculated uncertainties). The growth of high-temperature TL peaks, with increasing ionization density, was observed for MCP-N, what was not previously reported. At the whole range of applied energies higher efficiencies were noted for MTS......-N, for all ion species. A decrease of the efficiency with decrease of the ion energy was confirmed, for both types of studied detectors. At a given energy, higher efficiency was observed for lighter ions, because of the lower ionization density. Significantly higher decrease of the efficiency was measured...

  3. Evaluation of the response of thermoluminescent detectors in clinical beams dosimetry using different phantoms; Avaliacao da resposta de detectores termoluminescentes na dosimetria de feixes clinicos utilizando diferentes objetos simuladores

    Energy Technology Data Exchange (ETDEWEB)

    Matsushima, Luciana Cardoso

    2010-07-01

    Radiotherapy is one of the three principal treatment modalities used in the treatment of malignant diseases such as cancer, the other two are chemotherapy and radiosurgery. In contrast to other medical specialties that rely mainly on the clinical knowledge and experience of medical specialists, radiotherapy, with its use of ionizing radiation in treatment of cancer, relies heavily on modern technology and the collaborative efforts of several professionals whose coordinated team approach greatly influences the outcome of the treatment. In the area of clinical dosimetry, an efficient and accurate calibration of the radiation beam ensures knowledge of the radiation dose delivered to the patient, allowing thus the success of radiotherapy. This study aims to compare the thermoluminescent response of calcium sulfate doped with dysprosium (CaSO{sub 4}:Dy) dosimeters produced by IPEN (6 mm in diameter and 0,8 mm tick) with the response of lithium fluoride (3,15 x 3,15 x 0,9 mm{sup 3}) doped with magnesium and titanium (LiF:Mg,Ti) in dosimetry of clinical photons (6 and 15 MV) and electrons beams (6 and 9 MeV) using solid water (RMI-457), water and PMMA phantoms. Initially, the dose-response curves were obtained for irradiation in cobalt-60 gamma radiation source in air (PMMA plates) and under electronic equilibrium conditions and for clinical electrons and photons beams at depth of maximum dose. The sensitivities of the thermoluminescent dosimeters were also evaluated and the values of their reproducibilities and intrinsic efficiency were determined for the response to different types of phantoms and radiation energy. The obtained results indicate that the main advantage of CaSO{sub 4}:Dy dosimeters is the enhanced sensitivity to radiation doses measured for {sup 60}Co, photons and electrons beams, thus representing a viable alternative for application in dosimetry in the radiotherapy area. (author)

  4. Thermoluminescent dosimetry: theory, materials and applications

    International Nuclear Information System (INIS)

    Rosa, L.A.R.da.

    1978-01-01

    A survey about the thermoluminescence theory, the properties of the main thermoluminescent phosphors and their applications is presented. Some of the most important thermoluminescent readers are also mentioned [pt

  5. Datation par thermoluminescence

    Directory of Open Access Journals (Sweden)

    1976-01-01

    Full Text Available Depuis 1953, de nombreux chercheurs se sont intéressés à la datation par thermoluminescence de minéraux anciennement brûlés ou cuits. Dans ce travail, après avoir rappelé quelques principes physiques de la thermoluminescence, on présente cette méthode de datation en mettant l'accent sur le mécanisme thermoluminescent dans une poterie. Ainsi la dose d'irradiation reçue par le matériau étant proportionnelle au temps écoulé depuis le 'zéro archéologique', il est possible de déterminer 'la dose archéologique' et d'en déduire l'âge de l'échantillon après avoir calculé la dose d'irradiation annuelle. La réalisation pratique d'un tel ensemble de mesure est cependant très ardue. Dans un prochain article, E. A. Decamps et A. Roman montreront des résultats relatifs à la thermoluminescence d'échantillons de quartz naturels, purs et dopés et la mise au point d'une nouvelle méthode de datation. Desde 1953, muchos investigadores se han interesado en la datación por termoluminiscencia de minerales antiguamente quemados o cocidos. Dentro de este trabajo, luego de haber recordado algunos principios físicos de la termoluminiscencia, se presenta este método de datación poniendo mayor atención en el mecanismo termoluminescente en una vasija de metal o de barro. Siendo proporcional la dosis de irradiación recibida al tiempo transcurrido desde el 'cero arqueológico', es posible determinar 'la dosis arqueológica', y deducir la edad de la muestra luego de haber calculado la dosis de irradiación anual. La realización práctica de un trabajo de tal dimensión es sin embargo muy ardua. En un próximo artículo, E. A. Decamps y A. Román presentarán los resultados relativos a la termoluminiscencia de muestras de cuarzo naturales, puras y dopadas y la elaboración de un nuevo método de datación. Since 1953, a number of scientists have been concerned with the use of thermoluminescence for the dating of burned or fired minerals

  6. Thermoluminescence of kaolinite

    OpenAIRE

    García-Guinea, Javier; Correcher, Virgilio; Valle Fuentes, Francisco José

    1998-01-01

    Natural kaolinite (size < 5 ¿m) shows strong thermoluminescence (TL) which could be linked with water loss (~ 120°C peak) and dehydroxylation changes (~ 300°C peak). After 100 min of dehydration at room temperature, kaolinite displays microcracks, isothermal luminescence emissions and the starting point of a desiccation plateau. These phenomena were tested through 34 X ray diffractograms measuring the area increase of the (001) peak each 3 min. The DTA-TG analyses of natural kaolinite and the...

  7. Thermoluminescence studies in geology

    International Nuclear Information System (INIS)

    Sankaran, A.V.; Sunta, C.M.; Nambi, K.S.V.; Bapat, V.N.

    1980-01-01

    Even though the phenomenon of thermoluminescence is well studied, particularly over last 3 decades, its potentialities in the field of geology have not been adequately evaluated. In this report several useful applications of TL in mineralogy, petrogenesis, stratigraphy, tectonics, ore-prospecting and other branches have been identified with particular emphasis to the Indian scene. Important areas in the country that may provide the basic material for such studies are indicated at the end along with brief geological or mineralogical accounts. (auth.)

  8. Thermoluminescence spectra of amethyst

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Q. [Suzhou Railway Teachers College (China). Dept. of Physics; Yang, B. [Beijing Normal University (China). Dept. of Physics; Wood, R.A.; White, D.R.R.; Townsend, P.D.; Luff, B.J. [Sussex Univ., Brighton (United Kingdom). School of Mathematical and Physical Sciences

    1994-04-01

    Thermoluminescence and cathodoluminescence data from natural and synthetic amethyst and synthetic quartz samples are compared. The spectra include features from the quartz host lattice and from impurity-generated recombination sites. Emission features exist throughout the wavelength range studied, 250-800 nm. The near infrared emission at 740-750 nm appears to be characteristic of the amethyst and is proposed to be due to Fe ion impurity. (Author).

  9. Thermoluminescence - physics and applications

    International Nuclear Information System (INIS)

    Sunta, C.M.

    1992-01-01

    The interaction of ionizing radiations with matter leads to various effects, some of which leave memory in the target material. These memory effects can be seen as the after-effects of the irradiation. Thermoluminescence is one such phenomenon in the insulating solids. This paper describes the sequence of the physical events beginning with the incidence of an ionizing particle, leading to a trail of atomic and electronic displacements which stabilize in the form of so called defect centres. These defects - interstitials, colour centres, etc., store energy in their configuration. Most of the damage effects are reversible. The return of the displaced entities to their original site leads to the release of the stored energy. Thermoluminescence is the result of the re-adjustment (relaxation) of the displaced electrons. The stimulation for the relaxation process is provided by heating of the irradiated sample. The kinetics of the thermoluminescence process has been explained phenomenologically. The correspondence between the defect centres and the TL glow peaks has remained vague or ambiguous even in the most widely studied TL materials. Notwithstanding this deficiency, the phenomenon has found many practical applications. The paper deals mainly with the physical processes involved in the TL emission and alludes briefly to its involvement in applied areas.(author). 6 refs., 2 figs

  10. Assessment of CaSO{sub 4}:Dy and LiF:Mg,Ti thermoluminescent dosimeters performance in the dosimetry of clinical electron beams; Avaliacao do desempenho dos detectores termoluminesncetes de CaSO{sub 4}:Dy e LiF:Mg,Ti na dosimetria de feixes clinicos de eletrons

    Energy Technology Data Exchange (ETDEWEB)

    Nunes, Maira Goes

    2008-07-01

    The assessment of the performance of CaS0{sub 4}:Dy thermoluminescent detectors produced by IPEN in the dosimetry of clinical electron beams aims to propose an alternative to the LiF:Mg,Ti commercial dosimeters (TLD-100) largely applied in radiation therapy. The two types of thermoluminescent dosimeters were characterised with the use of PMMA, RMI-457 type solid water and water phantoms in radiation fields of 4, 6, 9, 12 and 16 MeV electrons of nominal energies in which the dose-response curves were obtained and the surface and depth doses were determined. The thermoluminescent response dependency with the electron nominal energies and the applied phantom were studied. The CaS0{sub 4}:Dy presented the same behaviour than the LiF:Mg,Ti in such a way that its application as an alternative to the TLD-100 pellets in the radiation therapy dosimetry of electron beams is viable and presents the significantly higher sensitivity to the electron radiation as its main advantage. (author)

  11. Development of ionizing radiations dosimetry by plastic detectors and films of radiography; Desenvolvimento de dosimetria de radiacoes ionizantes por detectores plasticos e filmes de radiografia

    Energy Technology Data Exchange (ETDEWEB)

    Levit, Vladimir; Santos, Ari S.; Louzada, Ana R.; Silveira, Cristina M.; Vaniel, Ana P. [Pelotas Univ., RS (Brazil). Inst. de Quimica e Geociencias]. E-mail: vlevit@ufpel.tche.br; Fedorov, Dmitri [Instituto Nacional de Pesquisas Espaciais (INPE), Sao Jose dos Campos, SP (Brazil)]. E-mail: fedorov@nucleo.inpe.br

    2000-07-01

    This work shows the development of an automatic and computerized system for detection and analysis of the ionizing radiation trace in solid detectors and one of the signals of this irradiation in radiography films with the main goal of improve the ionizing radiation detection methods. On the development of this method it was used a calibration source of {sup 252}Cf, which is a radionuclide with alpha decay and spontaneous fission and, by this reason, irradiates {alpha} and {gamma} particles and nuclear fragments. Solid detectors of makrofol ware used for the nuclear fragments and radiography films ware used for the detection of {alpha} and {gamma} particles. Those signals images reveled of the {alpha} and {gamma} particles and of the nuclear fragments traces ware analysed on a microscopy and recorded on computers. The computer system developed allows to capture those images from the microscope as computer files, the identification of nuclear fragments traces and the {alpha} and {gamma} particles signals and the separation of the objects of interest to do the counting and analysis of the size and the shape of those traces.

  12. Development of image capture system of fission tracks in plastic detectors; Desenvolvimento de sistema de captura de imagens de tracos nucleares em detectores plasticos

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Elder M. de; Melo, Vicente P. [Instituto de Radioprotecao e Dosimetria (IRD), Rio de Janeiro, RJ (Brazil). Dept. de Protecao Radiologica Ambiental

    2001-07-01

    Plastic detectors are appropriate for detection and registration of alpha particles and fission products. The interaction of these particles with the detector damage its molecular structure, leading to a latent track (visible only under an electronic microscope) with diameter in the nanometer magnitude order. There are two etching methods: the conventional and the electrochemistry one. In the conventional etching the usual conditions is to attack with NaOH 6M, producing a track of average diameter of 3 {mu} m. In the electrochemistry etching the diameter is {approx} 150 {mu}m. The aim of this work is to show the functionality of the scanner for the acquisition of these images in conditions of electrochemistry etching. We employed the following attack solution: KOH/C{sub 2}H{sub 5}OH 15% p/v, pre-etching of 30 minutes, etching with tension of 1000 V, frequency of 100 Hz, during an hour and another stage of an hour, with frequency of 8 kHz. The images were acquired with optical resolution of 400 dpi and amplification of 300%, what allows printing in paper or counting and observation of the tracks in the screen. Results have shown that the replacement of the conventional system by a scanner computer device can be performed without loss of reliability of confidence in the tracks measurement and observation. (author)

  13. Development and characterization of two-component albedo based neutron individual monitoring system using thermoluminescent detectors; Desenvolvimento e caracterizacao de um sistema de monitoracao individual de neutrons tipo albedo de duas componentes usando detectores termoluminescentes

    Energy Technology Data Exchange (ETDEWEB)

    Martins, Marcelo Marques

    2008-07-01

    A TLD-albedo based two-component neutron individual monitoring system was developed and characterized in this work. The monitor consists of a black plastic holder, an incident neutron boron loaded shield, a moderator polyethylene body (to increase its response), two pairs of TLD-600 and TLD-700 (one pair to each component) and an adjustable belt. This monitoring system was calibrated in thermal neutron fields and in 70 keV, 144 keV, 565 keV, 1.2 MeV and 5 MeV monoenergetic neutron fields. In addition, it was calibrated in {sup 252C}f(D{sub 2}O), {sup 252}Cf, {sup 241}Am-B, {sup 241}Am-Be and {sup 238}Pu-Be source fields. For the latter, the lower detection levels are, respectively, 0.009 mSv, 0.06 mSv, 0.12 mSv, 0.09 mSv and 0.08 mSv. The participation in an international intercomparison sponsored by IAEA with simulated workplace fields validated the system. The monitoring system was successfully characterized in the ISO 21909 standard and in an IRD - the Brazilian Institute for Radioprotection and Dosimetry - technical regulation draft. Nowadays, the neutron individual system is in use by IRD for whole body individual monitoring of five institutions, which comprehend several activities. (author)

  14. Thermoluminescence measurements of neutron streaming through JET Torus Hall ducts

    OpenAIRE

    Obryk, Barbara; Batistoni, Paola; Conroy, Sean; Syme, Brian D.; Popovichev, Sergey; Stamatelatos, Ion E.; Vasilopoulou, Theodora; Bilski, Paweł; Contributors, JET EFDA

    2014-01-01

    Thermoluminescence detectors (TLD) were used for dose measurements at JET. Several hundreds of LiF detectors of various types, standard LiF:Mg,Ti and highly sensitive LiF:Mg,Cu,P were produced. LiF detectors consisting of natural lithium are sensitive to slow neutrons, their response to neutrons being enhanced by 6Li-enriched lithium or suppressed by using lithium consisting entirely of 7Li. Pairs of 6LiF/7LiF detectors allow distinguishing between neutron/non-neutron components of a radiatio...

  15. Thermoluminescence: its understanding and applications

    International Nuclear Information System (INIS)

    Nambi, K.S.V.

    1977-01-01

    The phenomenon of thermoluminescence is treated exhaustively both mathematically and physically. All the possible applications of the phenomenon are briefly described and an optimistic picture of the future trends in this field is projected. A review of latest information on thermoluminescence instrumentation and phosphors is also included [pt

  16. Intermediate neutron detection by thermoluminescence

    International Nuclear Information System (INIS)

    Santos, E.N. dos; Muccillo, R.

    1979-01-01

    Thermoluminescent (TL) studies were carried out in cold-pressed CaSO 4 :Dy + Dy 2 O 3 + KCl and CaF 2 + Dy 2 O 3 + KCl polycrystalline samples exposed to mixed neutron-gamma fields, for the detection of intermediate neutrons which is based on the evaluation of the TL signal of the specimens stored for 24 hours after being exposed to a mixed neutron-gamma field and thermally annealed to erase the total radiation-induced TL. The addition of Dy 2 O 3 to CaSO 4 :Dy in the proportion 1:2 increased the neutron response by a factor of 160 relative to that of CaSO 4 :Dy. 180 mg of CaSO 4 :Dy + Dy 2 O 3 + KCl in the proportion 2:1:3 showed to be an appropriate detector of intermediate neutrons; the minimum detectable fluence was estimated to be 3.5 x 10 5 neutrons/cm 2 . (Author) [pt

  17. Development of an area monitor for neutrons using solid state nuclear track detector; Desenvolvimento de um monitor de area para neutrons utilizando detector solido de tracos nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Zahn, G.S.

    1994-12-31

    An area monitor for neutrons composed of the solid state nuclear track detector (SSNTD) Makrofol DE, together with a (n,{alpha}) converter, in the center of a 25 cm diameter polyethylene sphere, is developed. The optimal electrochemical etching conditions for the detection of thermal neutrons by the Makrofol DE using the BN converter are studied, leading to the choice of 55 min, at 30{sup 0} C, under a 44,2 kV.cm{sup -1} electric field with oscillation frequency of 2,0 khz. The response of this system to thermal neutrons, in the optimal conditions, is of 2,76(10)x 10{sup -3} tr/n. Changing from the BN converter to a 2,73(3)g compressed boric acid tablet this value lowers to 3,88(17)x 10{sup -4} tr/n. The performance of the whole monitor in the detection of fast neutrons is examined using the BN converter and neutrons from a {sup 241} Am Be source, with a response of 4,4(2)x 10{sup 3} tr.mSv{sup -1}.cm{sup -2} and operational limits between 7(3){mu}Sv and 5,6(2)mSv. The result of the monitoring of the control room of the IPEN Cyclotron accelerator are also presented as a final test for the viability of the practical use of the monitor. (author). 34 refs, 15 figs, 6 tabs, 1 app.

  18. Development of crystals based in cesium iodide for application as radiation detectors; Desenvolvimento de cristais baseados em iodeto de cesio para aplicacao como detectores de radiacao

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Maria da Conceicao Costa

    2006-07-01

    Inorganic scintillators with fast luminescence decay time, high density and high light output have been the object of studies for application in nuclear physics, high energy physics, nuclear tomography and other fields of science and engineering. Scintillation crystals based on cesium iodide (CsI) are matters with relatively low higroscopy, high atomic number, easy handling and low cost, characteristics that favor their use as radiation detectors. In this work, the growth of pure CsI crystals, CsI:Br and CsI:Pb, using the Bridgman technique, is described. The concentration of the bromine doping element (Br) was studied in the range of 1,5x10{sup -1} M to 10{sup -2} M and the lead (Pb) in the range of 10{sup -2} M to 5x10{sup -4} M. To evaluate the scintillators developed, systematic measurements were carried out for luminescence emission and luminescence decay time for gamma radiation, optical transmittance assays, Vickers micro-hardness assays, determination of the doping elements distribution along the grown crystals and analysis of crystals response to the gamma radiation in the energy range of 350 keV to 1330 keV and alpha particles from a {sup 241}Am source, with energy of 5.54 MeV. It was obtained 13 ns to 19 ns for luminescence decay time for CsI:Br and CsI:Pb crystals. These results were very promising. The results obtained for micro-hardness showed a significant increase in function of the doping elements concentration, when compared to the pure CsI crystal, increasing consequently the mechanical resistance of the grown crystals. The validity of using these crystals as radiation sensors may be seen from the results of their response to gamma radiation and alpha particles. (author)

  19. Thermoluminescent system for low temperatures

    International Nuclear Information System (INIS)

    Rosa, L.A.R. da; Caldas, L.V.E.; Leite, N.G.

    1988-09-01

    A system for measurements of the thermoluminescent glow curve, the thermoluminescent emission spectrum and the optical absorption spectrum of solid samples, from liquid nitrogen temperature up to 473 K, is reported. A specially designed temperature programmer provides a linear heating of the sample at a wide range of selectable heating rates, as also long term steady-state temperatures for annealing and isothermal decay studies. The system operates at a pressure of 1.33 x 10 -3 Pa. Presently it is being used for lithium fluoride low temperature thermoluminescent studies. (author) [pt

  20. Thermoluminescence in medical dosimetry

    International Nuclear Information System (INIS)

    Rivera, T.

    2011-10-01

    The dosimetry by thermoluminescence (Tl) is applied in the entire world for the dosimetry of ionizing radiations specially to personal and medical dosimetry. This dosimetry method has been very interesting for measures in vivo because the Tl dosimeters have the advantage of being very sensitive in a very small volume and they are also equivalent to tissue and they do not need additional accessories (for example, cable, electrometer, etc.) The main characteristics of the diverse Tl materials to be used in the radiation measures and practical applications are: the Tl curve, the share homogeneity, the signal stability after the irradiation, precision and exactitude, the response in function with the dose and the energy influence. In this work a brief summary of the advances of the radiations dosimetry is presented by means of the thermally stimulated luminescence and its application to the dosimetry in radiotherapy. (Author)

  1. Mexican gems as thermoluminescent dosimeters

    International Nuclear Information System (INIS)

    Azorin N, J.

    1979-01-01

    The possibility of using naturally ocurring mexican gems as thermoluminescent dosimeters (TLD) was investigated. Twelve types of gems were irradiated with X and gamma rays in order to determinate their dosimetric properties. Three of these gems showed favorable thermoluminescent characteristics compared with commercial thermoluminescent dosimeters. The plots of their thermoluminescent response as a function of gamma dose are straight lines on full log paper in the dose range 10 -2 to 10 2 Gy. The energy dependence is very strong to low energies of the radiation. Their fading was found to be about 5%/yr. and they may be annealed as reused without loss in sensitivity. Therefore, these gems can be used as X and gamma radiation dosimeters. (author)

  2. Thermoluminescence study of quartzite in a gold and uranium mineralized zone (Canavieiras, Jacobina-Bahia)

    International Nuclear Information System (INIS)

    Ferreira, J.

    1973-01-01

    The quartzite of Canavieiras gold mine (Jacobina-Bahia, Brazil) shows in its natural glow curve, a high temperature. The study of the reproductibility of this peak resulted in the standartization of measurement for grain sizes between 80 and 100 mesh. ''In Situ'' total gamma-ray profiles were made using a scintillation detector for the study the distribution of radioactive elements near the pirite, uranium and gold strike. In the interpretation of the profiles it was possible to shown a positive correlation between thermoluminescence and uranium yields. The thermoluminescence peak is sufficiently high temperature peak to let thermoluminescence accumulate at ambient temperatures. It was used in attempt to estimate the time and the event that enitiated the accumulation of thermoluminescence. The result obtained, (7 - + 4).10 6 years, may correspond to the last heating of the rocks at relatively recent time. (C.D.G.) [pt

  3. Calibration procedure for thermoluminescent dosemeters in water absorbed doses for Iridium-192 high dose rate sources

    International Nuclear Information System (INIS)

    Reyes Cac, Franky Eduardo

    2004-10-01

    Thermoluminescent dosimeters are used in brachytherapy services quality assurance programs, with the aim of guaranteeing the correct radiation dose supplied to cancer patients, as well as with the purpose of evaluating new clinical procedures. This work describes a methodology for thermoluminescent dosimeters calibration in terms of absorbed dose to water for 192 Ir high dose rate sources. The reference dose used is measured with an ionization chamber previously calibrated for 192 Ir energy quality, applying the methodology proposed by Toelli. This methodology aims to standardizing the procedure, in a similar form to that used for external radiotherapy. The work evolves the adaptation of the TRS-277 Code of the International Atomic Energy Agency, for small and big cavities, through the introduction for non-uniform experimental factor, for the absorbed dose in the neighborhood of small brachytherapy sources. In order to simulate a water medium around the source during the experimental work, an acrylic phantom was used. It guarantees the reproducibility of the ionization chamber and the thermoluminescent dosimeter's location in relation to the radiation source. The values obtained with the ionization chamber and the thermoluminescent dosimeters, exposed to a 192 Ir high dose rate source, were compared and correction factors for different source-detector distances were determined for the thermoluminescent dosimeters. A numeric function was generated relating the correction factors and the source-detector distance. These correction factors are in fact the thermoluminescent dosimeter calibration factors for the 192 Ir source considered. As a possible application of this calibration methodology for thermoluminescent dosimeters, a practical range of source-detector distances is proposed for quality control of 192 Ir high dose rate sources. (author)

  4. Thermoluminescence dating of dental enamel

    International Nuclear Information System (INIS)

    Benkoe, L.; Koszorus, L.

    1980-01-01

    Thermoluminescent response of the synthetic hydroxylapatite was studied, this material being the fundamental inorganic constituent of dental enamel. In order to make an attempt at archaeological TL dating of teeth, a chemical deproteination procedure of enamel was established, and the pre-dose effects of separated mineral grains extracted from 100 to 6000 years old human teeth were investigated. (orig.)

  5. Thermoluminescence dosimetry environmental monitoring system

    International Nuclear Information System (INIS)

    Bortoluzzi, S.

    1989-01-01

    In this report, characteristics and performances of an environmental monitoring system with thermoluminescence dosimetry are presented. Most of the work deals with the main physical parameters necessary for measurements of ambiental dose. At the end of this report some of level doses in the environment around the site of the ENEA Center of Energy Research Salluggia (Italy) are illustrated

  6. Photoluminescence and thermoluminescence properties of ...

    Indian Academy of Sciences (India)

    WINTEC

    Kanazawa T 1989 Inorganic phosphate materials, in Materials science monographs (Amsterdam: Elsevier) 52. Kottaiswamy M, Mohan Rao M and Jayakumar D 1997 Proc. nat. conf. on luminescence and its applications (New Delhi: Allied Publishers) p. 153. Mckeever S W S 1985 Thermoluminescence of solids (Cam-.

  7. Photoluminescence and thermoluminescence properties of ...

    Indian Academy of Sciences (India)

    WINTEC

    Abstract. The suitability of calcium phosphate crystals for thermoluminescence dosimetry (TLD) applica- tions is investigated, owing to their equivalence to bone mineral. The α and β phases of tricalcium phosphate. (TCP) were synthesized through wet precipitation and high temperature solid state routes and doped with Dy.

  8. Evaluation of the thermoluminescent detector answers of CaSO4:Dy, LiF:Mg,Ti and micro LiF:Mg,Ti in photon clinical beams dosimetry using water simulator

    International Nuclear Information System (INIS)

    Matsushima, Luciana C.; Veneziani, Glauco R.; Campos, Leticia L.

    2011-01-01

    This paper perform the comparative study of thermoluminescent answer of calcium sulfate dosemeter doped with dysprosium (DaSO 4 :Dy) produced by the IPEN, Sao Paulo, with answer of lithium fluoride dosemeters doped with magnesium and titanium (LiF:Mg, Ti) in the dosimetry of clinical beams of photons (6 and 15 MV) by using water simulator object. Dose-answer curves were obtained for gamma radiation of cobalt-60 in the air and in conditions of electronic equilibrium (plate of PMMA), and clinical photons of CLINAC model 2100C accelerators of the two evaluated hospitals: Hospital das Clinicas of the Faculty of Medicine of Sao Paulo university and Hospital Albert Einstein. It was also evaluated the sensitivity and reproduction of the three dosemeters

  9. Technical recommendations for the use of thermoluminescence for dosimetry in individual monitoring for photons and electrons from external sources

    International Nuclear Information System (INIS)

    1975-01-01

    The principles of thermoluminescence dosimetry and the role it may play in the field of personnel dosimetry are presented. Technical recommendations are made as an indication of what is generally regarded as good practice and they are intended to be of assistance in avoiding the common sources of error. Errors due to: the detector; the evaluation procedure; the thermal treatment; at the sensitivity of the detector to neutrons. The recommendations are concerned with: the choice of detector material; design of thermoluminescent dosemeters; read-out procedure; reader; handling procedures; dose evaluations; automation; documentation and data handling

  10. Selected references on thermoluminescent dosemeters for personnel monitoring

    International Nuclear Information System (INIS)

    Lawson, Helen

    1976-08-01

    This bibliography contains references on: specific thermoluminescent dosemeters used for personnel dosimetry; comparisons of thermoluminescent and other dosemeters for personnel monitoring and read-out apparatus for thermoluminescent dosemeters. An appendix contains selected foreign language references. (author)

  11. Thermoluminescence Dosimetry Applied to Radiation Protection

    DEFF Research Database (Denmark)

    Christensen, Poul; Bøtter-Jensen, Lars; Majborn, Benny

    1982-01-01

    , fading, and LET dependence. The applications of thermoluminescence dosimetry in routine personnel monitoring, accident dosimetry, u.v. radiation dosimetry, and environmental monitoring are discussed with particular emphasis on current problems in routine personnel monitoring. Finally, the present state......This is a general review of the present state of the development and application of thermoluminescence dosimetry (TLD) for radiation protection purposes. A description is given of commonly used thermoluminescent dosimeters and their main dosimetric properties, e.g. energy response, dose range...

  12. Performance of thermoluminescent materials for high dose dosimetry

    International Nuclear Information System (INIS)

    Texeira, Maria I.; Cecatti, Sonia G.P.; Caldas, Linda V.E.

    2008-01-01

    Cases involving high-doses of ionizing radiation are becoming increasingly common.The objective of this work was to characterize thermoluminescent materials for the dosimetry of workers exposed to high doses. Samples of TLD-200, TLD-400 and TLD-800 pellets from Thermo Electron Corporation were studied in gamma high-doses. Dose-response curves were obtained for doses between 100 mGy and 100 Gy. The reproducibility, the lower detection limits and dose-response curves were obtained for all three materials. The different kinds of detectors show usefulness for dosimetry of workers exposed accidentally to high doses. (author)

  13. Numerical analysis of thermoluminescence glow curves

    International Nuclear Information System (INIS)

    Gomez Ros, J. M.; Delgado, A.

    1989-01-01

    This report presents a method for the numerical analysis of complex thermoluminescence glow curves resolving the individual glow peak components. The method employs first order kinetics analytical expressions and is based In a Marquart-Levenberg minimization procedure. A simplified version of this method for thermoluminescence dosimetry (TLD) is also described and specifically developed to operate whit Lithium Fluoride TLD-100. (Author). 36 refs

  14. A kinetic model of zircon thermoluminescence

    NARCIS (Netherlands)

    Turkin, A.A.; Es, H.J. van; Vainshtein, D.I.; Hartog, H.W. den

    A kinetic model of zircon thermoluminescence (TL) has been constructed to simulate the processes and stages relevant to thermoluminescent dating such as: filling of electron and hole traps during the excitation stage both for natural and laboratory irradiation; the time dependence of fading after

  15. Thermoluminescent measurement in space radiation dosimetry

    International Nuclear Information System (INIS)

    Chen Mei; Qi Zhangnian; Li Xianggao; Huang Zengxin; Jia Xianghong; Wang Genliang

    1999-01-01

    The author introduced the space radiation environment and the application of thermoluminescent measurement in space radiation dosimetry. Space ionization radiation is charged particles radiation. Space radiation dosimetry was developed for protecting astronauts against space radiation. Thermoluminescent measurement is an excellent method used in the spaceship cabin. Also the authors mentioned the recent works here

  16. Thermoluminescence spectra measured with a Michelson interferometer

    International Nuclear Information System (INIS)

    Haschberger, P.

    1991-01-01

    A Michelson interferometer was redesigned to prove its capabilities in the measurement of short-lived, low-intensity thermoluminescence spectra. Interferograms are collected during heating up the thermoluminescent probe in a heater plate. A personal computer controls the data acquisition and processes the Fourier transform. As the results show, even a comparatively simple and limited setup leads to relevant and reproducible spectra. (author)

  17. Thermoluminescence study of lithium fluorides

    CERN Document Server

    Abu-Alazm, S M

    2003-01-01

    The spectrum of the light emitted during thermoluminescence (TL) from irradiated lif sample with different doses of Xe, Kr and electrons have been studied. The results show a main peak for all samples irradiated and unirradiated at temperature about 200 degree C. Morcever when the reaches to the value 5x10 sup 1 1 ion/cm sup 2 a new two bands begin to appear in case of Xe and Kr ion irradiation. The TL spectra under Kr and Xe ion irradiation similar at the same dose. However, the spectra under electron irradiation were found to be rather different than under heavy ions irradiation.

  18. Thermoluminescence dating of pleistocene sediments

    International Nuclear Information System (INIS)

    Poupeau, G.; Souza, J.H.; Rivera, A.

    1984-01-01

    After a short introduction on recent trends in quaternary geochronology, this article focuses on the thermoluminescence dating of sediments, whose principles and present limits and prospects are discussed. Results are presented for the TL behaviour of sands from various geological contexts in Brazil. They show that the coarse (approx. 100-200μm) quartz fraction of coastal and intra continental, eolian and fluvial-type deposits, might be datable by TL from the upper Holocene to at least the basis of the upper Pleistocene, with a precision of + - 10-15%. (Author) [pt

  19. Thermoluminescence dating of pleistocene sediments

    International Nuclear Information System (INIS)

    Poupeau, G.; Souza, J.H.

    1984-01-01

    After a short introduction on recent trends in quaternary geochronology, this article focuses on the thermoluminescence (TL) dating of sediments, whose principles, present limits and prospects are discussed. Results are presented for TL behavior of sands from various geological contexts in Brazil. They show that the coarse (approx. 100-200 μm) quartz fraction of coastal and intracontinental, eolian and fluvial - type deposits, might be datable by TL from the upper Holocene to at least the base of the upper Pleistocene, with a precision of +- 10-15%. (Author) [pt

  20. Desenvolvimento de um detector piezelétrico para cromatógrafo a gás interfaceado a microcomputador

    Directory of Open Access Journals (Sweden)

    Jesus Dosil P. de

    1999-01-01

    Full Text Available A piezoelectric detector based on a commercial quartz crystal of 3.57MHz is shown. A PTFE cell attached to the GC-column outlet holds the polymer-coated crystal, whose terminals were removed. Two TTL oscillators (reference and sensor are used and the beating of their frequencies is monitored through a home-made counter card inserted in a microcomputer. The original thermal conductivity detector was also interfaced, but through a 12-bit analog-to-digital converter. In spite of the well-known fact that QCM has low sensitivity at high temperatures, results show significant peak deformation for low temperatures. In addition, the phenomenon is also dependent on the chemical composition of the absorbent film besides instantaneous partial pressure and chemical composition of the analyte.

  1. Development of TiBr semiconductor crystal for applications as radiation detector and photodetector; Desenvolvimento do cristal semicondutor de brometo de talio para aplicacoes como detector de radiacao e fotodetector

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Icimone Braga de

    2006-07-01

    In this work, Tlbr crystals were grown by the Bridgman method from zone melted materials. The influence of the purification efficiency and the crystalline surface quality on the crystal were studied, evaluating its performance as a radiation detector. Due to significant improvement in the purification and crystals growth, good results have been obtained for the developed detectors. The spectrometric performance of the Tlbr detector was evaluated by {sup 241}Am (59 keV), {sup 133}Ba (80 e 355 keV), {sup 57}Co (122 keV), {sup 22}Na (511 keV) and {sup 137} Cs (662 keV) at room temperature. The best energy resolution results were obtained from purer detectors. Energy resolutions of 10 keV (16%), 12 keV (15%), 12 keV (10%), 28 keV (8%), 31 keV (6%) and 36 keV (5%) to 59, 80, 122, 355, 511 and 662 keV energies, respectively, were obtained. A study on the detection response at -20 deg C was also carried out, as well as the detector stability in function of the time. No significant difference was observed in the energy resolution between measurements at both temperatures. It was observed that the detector instability causes degradation of the spectroscopic characteristics during measurements at room temperature and the instability varies for each detector. This behavior was also verified by other authors. The viability to use the developed Tlbr crystal as a photodetector coupled to scintillators crystals was also studied in this work. Due to its quantum efficiency in the region from 350 to 500 nm, Tlbr shows to be a promising material to be used as a photodetector. As a possible application of this work, the development of a surgical probe has been initiated using the developed Tlbr crystal as the radiation detector of the probe. (author)

  2. Study of a new dosimetric radio-thermoluminescent systems

    International Nuclear Information System (INIS)

    Cazac, T.C.

    1980-01-01

    This is the first Romanian study to investigate conditions to obtain the radio-thermo-luminescent systems: MgB 4 O 7 :A(A-Nd,Sm,Eu,Dy,Tb,Dy+Sm and Tb+Sm) MgF 2 A (A=Mn,Dy,Tb,Sm,Li), their essential dosimetric characters, as well as the (MgF 2 =Mn) thermophosphorus mixture with a ( 6 LiF) lithium target. An investigation was developed upon a new category of radio-thermoluminescent detectors with low radiation energy dependence and fading, magnesjum boride activated by several elements of the lanthanides class (Nd,Sm,Eu,Dy,Tb). A new radio-thermoluminescent dosimetric system with high sensitivity and moderate dependence on energy radiation - (Mnsup(2+)) manganese activated magnesium fluoride - was also studied. The author explored application of investigated detectors MgF 2 =Mn, MgB 4 O 7 =Dy and MgB 4 O 7 :Tb in neutron dosimetry in complex gamma-neutron fields. It is deemed that by using the dosimetric systems reported in the thesis in order to measure gamma, beta and neutron radiation doses, dosimetric control can be ensured both in professional dosimetry and in nuclear accident dosimetry, as well as in various basic and applicative investigations. A modest contribution is thus made towards achieving the national nuclear program through an extension of the thermophosphorus range with practical applications in nuclear radiation dosimetry. (author)

  3. Thermoluminescent dosimetry and assessment of personal dose

    International Nuclear Information System (INIS)

    Boas, J.F.; Martin, L.J.; Young, J.G.

    1982-01-01

    Thermoluminescence is discussed in terms of the energy band structure of a crystalline solid and the trapping of charge carriers by point defects. Some general properties of thermoluminescent materials used for dosimetry are outlined, with thermoluminescence of CaSO 4 :Dy being described in detail. The energy response function and the modification of the energy response of a dosimeter by shielding are discussed. The final section covers the connection between exposure, as recorded by a TLD badge, and the absorbed dose to various organs from gamma radiation in a uranium mine; the conversion from absorbed dose to dose equivalent; and uncertainties in assessment of dose equivalent

  4. Thermoluminescence (TL) of Egyptian Blue

    Energy Technology Data Exchange (ETDEWEB)

    Schvoerer, M.; Delavergne, M.-C.; Chapoulie, R.

    1988-01-01

    Egyptian Blue is a synthesized crystalline pictorial pigment with formula CaCuSi/sub 4/O/sub 10/. It has been used in Egypt and Mesopotamia from the 3rd millenium B.C. A preliminary experiment on a recently synthesized sample showed that this pigment is thermoluminescent after ..beta.. irradiation (/sup 90/Sr). As the signal intensity grows linearly with the administered dose within the temperature range commonly used in TL dating, we have been looking for this phenomenon from archaeological pigments. It was encountered with two samples found in excavation. From its intensity and stability we concluded that Egyptian Blue can be dated using TL. This first and positive result encouraged us to extend the method to other types of mineral pigments synthesized by early man, and to suggest that it may be used for direct dating of ancient murals.

  5. Implantation of a new Beta Secondary Standard system at Centro de Desenvolvimento da Tecnologia Nuclear

    International Nuclear Information System (INIS)

    Reynaldo, Sibele Reis

    2005-01-01

    The crescent use of beta radiation sources in medical, industrial and research applications has increased the need for higher accuracy in beta dosimetry. As the first Beta Secondary Standard system (BSS1) was developed about 20 years ago, a new BSS2 system was made commercially available to fulfill new metrological demands and to follow the technological development. The BSS2 has a new positioning set-up, high activity and long half-life beta radiation sources and a special safety system. The Centro de Desenvolvimento da Tecnologia Nuclear is the first laboratory in Latin America that has got a BSS2. This work describes the BSS2 and it compares its advantages in relation to BSS1; results of the beam uniformity tests of the radiation fields from 90 Sr/ 90 Y, 85 Kr and 147 Pm sources, that were measured with an ionization chamber and with thermoluminescent detectors, are also shown. Results show that the beta radiation fields are considered to be uniform for diameters between 8 and 20 cm according to the chosen source. (author)

  6. Dose-rate dependence of thermoluminescence response

    International Nuclear Information System (INIS)

    McKeever, S.W.S.; Chen, R.; Groom, P.J.; Durrani, S.A.

    1980-01-01

    The previously observed dose-rate effect of thermoluminescence in quartz at high dose-rates is given at theoretical formulation. Computer calculations simulating the experimental conditions yield similar results to the experimental ones. (orig.)

  7. Personal radiation monitoring with thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Miano, S.C.

    1987-01-01

    The technique of personal dosimetry used by SAPRA (Servico de Assessoria e Protecao Radiologica S/C Ltda., Brazil) is presented. Thermoluminescent monitors and CaSO 4 : Dy are used in pastilles united by teflon. Characteristics of the dosemeters are briefly reported. The system of thermoluminescent measurement, designed and constructed by SAPRA, and the system of personal monitoring are described. (M.A.C.) [pt

  8. Personnel monitoring of radiations with thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Miano, S.C.

    1987-01-01

    The basics of personnel dosimetry technics, used by the Radiologic Protetion and Assessorie Service (SAPRA) are presented, consisting on use of thermoluminescent and CaSO 4 :Dy monitors in aggregated pellets by Teflon. The characteristics of this dosemeters, relating to the sensitivity, energetic dependence, spike temperature, characteristic emission curve, decay and light effect are shown. The thermoluminescent dosemeter measure system and the personnel monitoring system are also described. (C.G.C.) [pt

  9. Thermoluminescence of LaAlO3

    International Nuclear Information System (INIS)

    Morales H, A.; Zarate M, J.; Rivera M, T.; Azorin N, J.

    2015-10-01

    In this paper the thermoluminescent properties of doped lanthanum aluminate (LaAlO 3 ) with dysprosium ion (Dy) were studied. The thermoluminescence characteristics in the samples were obtained using an ultraviolet radiation of 220 nm. The LaAlO 3 :Dy samples were prepared by the modified Pechini method (Spray Dryer). The structural and morphological characterization was obtained by X-ray diffraction (XRD) and scanning electron microscopy (Sem) techniques respectively. The size particle composing the agglomerate was determined by Sem, agglomerated particles composed size of 2μm were observed. The thermoluminescence response of LaAlO 3 :Dy was compared with that obtained with the undoped sample. Thermoluminescence brightness curves of LaAlO 3 :Dy showed a peak centered at 185 grades C. Sensitivity of doped sample was greater, about 100 times compared with the undoped sample. Thermoluminescence response in function of the wavelength showed a maximum at 220 nm. Also the fading in thermoluminescence response was studied. (Author)

  10. Thermoluminescence dosimetry in very hot atmosphere with a view to the dosimetry in nuclear reactors

    International Nuclear Information System (INIS)

    Bikwaku, Nsampala Tomakunsimba

    1985-01-01

    In order to develop radiation resistant materials for use in the region of nuclear reactor cores, it is necessary to know the dose absorbed by the surrounding structures. A passive thermoluminescence technique was chosen, an activated alumina material with very deep traps which are stable at high temperature (450 deg. C), being used. The characteristic properties of this detector have been studied and an attempt made to interpret the results obtained. (author) [fr

  11. Thermoluminescent and optical processes in alkaline halogenides dosemeters contaminated with Europium

    International Nuclear Information System (INIS)

    Barboza F, M.; Melendrez, R.; Castaneda, B.; Pedroza M, M.; Chernov, V.; Perez S, R.; Aceves, R.

    2000-01-01

    Recent research results are presented about the properties of the optical processes of photo transferred thermoluminescence (TLFT), optical whitening (BO), thermoluminescence induced by light (TLL) and its effect in the thermoluminescent curve (Tl) produced by ionizing and non-ionizing radiation. The systematic analysis of all these processes, acquires a singular importance due that actually the alkaline halogenide crystals are object of intense investigations which analyse their potential applications as detectors and radiation dosemeters through stimulated optical luminescence techniques or thermoluminescence. The obtained data show that the Tl curve of material with this nature can be enormously affected by exposure of phosphorus to the environmental light or UV. This is in part due to liberation processes of charge bearers are shouted and makes a subsequent trapping in less temperature traps; at the same time that induce changes in the intensity of determined Tl bands. Additionally, also it is observed that mentioned phenomena are related as with wavelength of incident light as of the illumination time. Finally, the obtained information allows to conclude that although the illumination effect is extremely complex, it is associated and can be explained mainly with phenomena that implicate the electrons excitation trapped in form of F centers and trapping mechanisms or radioactive and non-radioactive recombination. (Author)

  12. New thermoluminescence techniques for mineral exploration

    Energy Technology Data Exchange (ETDEWEB)

    Levy, P W; Holmes, R J; Ypma, P J; Chen, C C; Swiderski, H S

    1977-01-01

    The thermoluminescence of carbonate host rock in the vicinity of known lead-zinc and lead-zinc-fluorite mineralization was reexamined for possible development as an exploration technique. The measurements were made with equipment for determining the thermoluminescence spectrum at closely spaced temperature intervals. Radiation-induced thermoluminescence was also measured. Samples were studied from five localities in Mexico, Southwest Africa, and the United States. Four thermoluminescence properties were found to vary with ''distance-from-ore'' in a systematic manner. These include the glow peak intensity and temperature and the emission spectrum peak energy and full width at half-maximum. For example, in both limestone and dolomite, the high-temperature glow peak intensities are low or negligible within the ore and as the distance from the contact increases the intensity rises rapidly to a maximum, or maxima, and then decreases irregularly to constant value slightly above that in the ore. Depending on the thickness of the ore, the thermoluminescence characteristics associated with the mineralization extended from ten to a hundred or so meters from the ore host rock contact. 5 figures. (DLC)

  13. Dosimetric of extremities with Dosemeters thermoluminescent in Cuba

    International Nuclear Information System (INIS)

    Molina Perez, D.; Diaz Bernal, E.; Vera Alonso, L.

    1998-01-01

    From final of the year 1995 in the CPHR implement the service of monitoring of the extremities using Dosemeter thermoluminescent (TL). The dosemeter consists on a metallic ring with a circular hole where a detector of LiF:Mg,Ti is placed (model JR1152C) of 5x5x0.9 mm 3 , covered by a fine layer of polyethylene. In the work the characteristic dosimetric as of the dosemeter is studied it satisfies the main requirements for their use in the monitoring from the exhibition to radiation photonic of the extremities. The doses are also presented registered during the first two years of operation of the service. The results obtained until the moment point out to you practice them of nuclear medicine, radiotherapy and production of substances radioactive how as of more contribution

  14. Development of sealed radioactive sources immobilized in epoxy resin for verification of detectors used in nuclear medicine; Desenvolvimento de fontes radioativas seladas imobilizadas em resina epoxi para verificacao de detectores utilizados em medicina nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Tiezzi, Rodrigo

    2016-07-01

    The radioactive sealed sources are used in verification ionization chamber detectors, which measure the activity of radioisotopes used in several areas, such as in nuclear medicine. The measurement of the activity of radioisotopes must be made with accuracy, because it is administered to a patient. To ensure the proper functioning of the ionization chamber detectors, standardized tests are set by the International Atomic Energy Agency (IAEA) and the National Nuclear Energy Commission using sealed radioactive sources of Barium-133, Cesium-137 and Cobalt-57. The tests assess the accuracy, precision, reproducibility and linearity of response of the equipment. The focus of this work was the study and the development of these radioactive sources with standard Barium-133 and Cesium-137,using a polymer, in case commercial epoxy resin of diglycidyl ether of bisphenol A (DGEBA) and a curing agent based on modified polyamine diethylenetriamine (DETA), to immobilize the radioactive material. The polymeric matrix has the main function of fix and immobilize the radioactive contents not allowing them to leak within the technical limits required by the standards of radiological protection in the category of characteristics of a sealed source and additionally have the ability to retain the emanation of any gases that may be formed during the manufacture process and the useful life of this artifact. The manufacturing process of a sealed source standard consists of the potting ,into bottle standardized geometry, in fixed volume of a quantity of a polymeric matrix within which is added and dispersed homogeneously to need and exact amount in activity of the radioactive materials standards. Accordingly, a study was conducted for the choice of epoxy resin, analyzing its characteristics and properties. Studies and tests were performed, examining the maximum miscibility of the resin with the water (acidic solution, simulating the conditions of radioactive solution), loss of mechanical and

  15. Laser heating of thermoluminescent films: Dose mapping applied to beta dosimetry

    DEFF Research Database (Denmark)

    Setzkorn, R.; Prévost, H.; Gasiot, J.

    1996-01-01

    and angular responses of CaSO4:Dy-based TL foils for irradiation in air with beta rays (Pm-147, (TI)-T-204 and Sr-90/Y-90). Laser scanning results are compared with results from measurements using very thin graphite-mixed MgB4O7Dy TL detectors. Results show that detectors based on CaSO4:Dy films......This work addresses radiation dose mapping based on scanning of laser heated thermoluminescent foils used for dose distribution analyses of beta radiation fields. Results are presented from dose homogeneity measurements, determination of depth-dose profile in tissue and studies of energy...

  16. Thermoluminescence: Potential Applications in Forensic Science

    Science.gov (United States)

    Ingham, J. D.; Lawson, D. D.

    1973-01-01

    In crime laboratories one of the most difficult operations is to determine unequivocally whether or not two samples of evidence of the same type were originally part of the same thing or were from the same source. It has been found that high temperature thermoluminescence (room temperature to 723 K) can be used for comparisons of this type, although work to date indicates that there is generally a finite probability for coincidental matching of glass or soil samples. Further work is required to determine and attempt to minimize these probabilities for different types of materials, and to define more clearly the scope of applicability of thermoluminescence to actual forensic situations.

  17. Development of thermoluminescence dating techniques at Oxford

    International Nuclear Information System (INIS)

    Fleming, S.J.

    1977-01-01

    The two-decade long history of thermoluminescene as a pottery dating method is surveyed with particular reference to the various problems that have been encountered in the Oxford Laboratory's research programme. Effects, such as supralinearity and radon emanation, are explained in terms of how they are measured and how their existence influences thermoluminescence (TL) dating accuracy (currently close to plus minus 7% per analysis). Illustrations of Thermoluminescence (TL) applications include a Nok culture terracotta from Nigeria and a Cambodia bronze Buddha figure of the Khmer period, dated ising the ceramic-like casting-core retained within it. (author)

  18. Photoluminescence, trap states and thermoluminescence decay ...

    Indian Academy of Sciences (India)

    Administrator

    Photoluminescence, trap states and thermoluminescence decay process study of Ca2MgSi2O7 : Eu. 2+. , Dy. 3+ phosphor. RAVI SHRIVASTAVA*, JAGJEET KAUR, VIKAS DUBEY and BEENA JAYKUMAR. Govt. VYT PG Autonomous College, Durg 491 001, (C.G.) India. MS received 9 July 2013; revised 5 December 2013.

  19. Thermoluminescence of zircon : a kinetic model

    NARCIS (Netherlands)

    Turkin, AA; van Es, HJ; Vainshtein, DI; den Hartog, HW

    2003-01-01

    The mineral zircon, ZrSiO4, belongs to a class of promising materials for geochronometry by means of thermoluminescence (TL) dating. The development of a reliable and reproducible method for TL dating with zircon requires detailed knowledge of the processes taking place during exposure to ionizing

  20. Mineral zircon : A novel thermoluminescence geochronometer

    NARCIS (Netherlands)

    Vanes, H.J.; Vainshtein, DI; De Meijer, RJ; Den Hartog, HW; Donoghue, JF; Rozendaal, A

    2002-01-01

    Mineral zircon contains trace amounts (typically 10-1000 ppm) of the alpha-emitters uranium and thorium, which irradiate this mineral internally. This outstanding feature of zircon turns out to be extremely useful when this mineral is applied as a thermoluminescence (TL) dating medium, because the

  1. Thermoluminescence of meteorites and their orbits

    Science.gov (United States)

    Melcher, C. L.

    1981-01-01

    The thermoluminescence levels of 45 ordinary chondrites are measured in order to provide information on the orbital characteristics of the meteorites before impact. Glow curves of the photon emission response of powdered samples of the meteorites to temperatures up to 550 C in the natural state and following irradiation by a laboratory test dose of 110,000 rad were obtained as functions of terrestrial age and compared to those of samples of the Pribram, Lost City and Innisfree meteorites, for which accurate orbital data is available. The thermoluminescence levels in 40 out of 42 meteorites are found to be similar to those of the three control samples, indicating that the vast majority of ordinary chondrites that survive atmospheric entry have perihelia in the range 0.8-1 AU. Of the remaining two, Farmville is observed to exhibit an unusually large gradient in thermoluminescence levels with sample depth, which may be a result of a temperature gradient arising in a slowly rotating meteorite. Finally, the thermoluminescence measured in the Malakal meteorite is found to be two orders of magnitude lower than control samples, which is best explained by thermal draining by solar heating in an orbit with a perihelion distance of 0.5 to 0.6 AU.

  2. Thermoluminescence dosimetry of rare earth doped calcium ...

    Indian Academy of Sciences (India)

    The thermoluminescence (TL) properties of calcium aluminate (CaAl2O4) doped with different rare earth ions have been studied and their suitability for radiation dosimetry applications is discussed. It is observed that monocalcium aluminate doped with cerium is a good dosimeter having linear response up to about 4 kGy of ...

  3. Thermoluminescence studies - application to earth sciences

    International Nuclear Information System (INIS)

    Sankaran, A.V.; Sunta, C.M.; Nambi, K.S.V.; Kaul, I.K.; Bhattacharya, A.K.

    1979-01-01

    Studies on the applications of thermoluminescence in the fields of petrogenesis, rock tectonics, ore prospecting, paleoclimatology, geological dating of mineralisation events, igneous activity, sediments and metamict minerals, sediment growth rate, stratigraphic correlation and diagenetic history are reviewed. (M.G.B.)

  4. Clay as Thermoluminescence Dosemeter in diagnostic Radiology ...

    African Journals Online (AJOL)

    As part of efforts to isolate and utilize local and naturally occurring materials for development of thermoluminescece dosemeters and other technologies, an earlier report had shown that Nigerian clay showed prospects of utility as a thermoluminescence dosemeter (TLD). This paper reports the investigation of the basic ...

  5. Photoluminescence, trap states and thermoluminescence decay ...

    Indian Academy of Sciences (India)

    ... solid-state reaction. The Fourier transform infrared (FT–IR) spectra confirmed the proper preparation of the sample. The prepared phosphors were characterized using photoluminescence excitation and emission spectra. Prominent green colour emission was obtained under ultraviolet excitation. The thermoluminescence ...

  6. Thermoluminescence dating of Hawaiian basalt

    Science.gov (United States)

    May, Rodd James

    1979-01-01

    The thermoluminescence (TL) properties of plagioclase separates from 11 independently dated alkalic basalts 4,500 years to 3.3 million years old and 17 tholeiitic basalts 16 years to 450,000 years old from the Hawaiian Islands were investigated for the purpose of developing a TL dating method for young volcanic rocks. Ratios of natural to artificial TL intensity, when normalized for natural radiation dose rates, were used to quantify the thermoluminescence response of individual samples for age-determination purposes. The TL ratios for the alkalic basalt plagioclase were found to increase with age at a predictable exponential rate that permits the use of the equation for the best-fit line through a plot of the TL ratios relative to known age as a TL age equation. The equation is applicable to rocks ranging in composition from basaltic andesite to trachyte over the age range from about 2,000 to at least 250,000 years before present (B.P.). The TL ages for samples older than 50,000 years have a calculated precision of less than :t 10 percent and a potential estimated accuracy relative to potassium-argon ages of approximately :t 10 percent. An attempt to develop a similar dating curve for the tholeiitic basalts was not as successful, primarily because the dose rates are on the average lower than those for the alkalic basalts by a factor of 6, resulting in lower TL intensities in the tholeiitic basalts for samples of equivalent age, and also because the age distribution of dated material is inadequate. The basic TL properties of the plagioclase from the two rock types are similar, however, and TL dating of tholeiitic basalts should eventually be feasible over the age range 10,000 to at least 200,000 years B.P. The average composition of the plagioclase separates from the alkalic basalts ranges from oligoclase to andesine; compositional variations within this range have no apparent effect on the TL ratios. The average composition of the plagioclase from the tholeiitic

  7. Thermoluminescence dating (TL-dating): measurement and accuracy factors in archaeological dating of ceramic base materials

    International Nuclear Information System (INIS)

    Wan Saffiey Wan Abdullah

    2004-01-01

    Thermoluminescence dating is one of the known techniques that have been established in many laboratories across the region. This technique is capable of dating the archaeological ceramic base materials and provide an absolute measurement with an accuracy of ±15%. The study involves the dating of pottery from a historical site at Sungai Mas, Mukim Kota, Daerah Kuala Muda, Kedah. Pieces of broken pottery of archaeological sample excavated by the Museum Department and Antiquity (JMA) have been dated using the thermoluminescence detector (TLD) techniques at MINT laboratory. A TLD dosemeter of LiF chips is used for the measurement of background and sample dose measurement. The preparation of sample and the calibration techniques for the estimation of palaedose or dose presented in the sample since distant past is established. Results indicate that the samples are in the era of civilization from 200 BP to 1600 BP. Error factors associated in the measurement procedures were identified and discussed. (Author)

  8. MEIO AMBIENTE E DESENVOLVIMENTO

    Directory of Open Access Journals (Sweden)

    Suely Salgueiro Chacon

    2009-12-01

    Full Text Available O objetivo deste artigo é resgatar elementos para subsidiar uma reflexão crítica sobre o modelo de desenvolvimento econômico prevalente na sociedade e as relações com o meio ambiente, sob a ameaça que ronda o destino da espécie humana, conforme afirmação de Lovelock (2006, p. 20 sobre o conceito de desenvolvimento sustentável: “uma ideia adorável se a tivéssemos aplicado 200 anos atrás, quando havia um bilhão de pessoas no mundo. Agora é tarde demais. Não há mais espaço para nenhum tipo de desenvolvimento. A humanidade tem que regredir”. Este artigo apresenta a evolução do conceito de desenvolvimento econômico sob a ótica da sustentabilidade, e interliga temas como: o ambientalismo, aglutinador de distintos pensamentos sobre as relações entre a sociedade e a natureza; o movimento ambiental, a fundamentar a disseminação do conceito de desenvolvimento sustentável, e a gestão ambiental, abordada como prática orientada pelo conceito de desenvolvimento sustentável.

  9. Phosphor for thermoluminescent type radiation dosimeter

    International Nuclear Information System (INIS)

    Nada, N.; Yamashita, T.

    1975-01-01

    This has the accumulation effect of radiation energy and is mainly used as the element for thermoluminescent type radiation dosimeters. It has as the principal constituent a phosphor consisting of calcium sulfate as the principal constituent and other impurity elements such as dysprosium, thulium and the like. It is more sensitive by the order of 1 to 2 or more figures than the conventional ones and is excellent in the retention of absorbed radiation energy. (U.S.)

  10. Gamma dose estimation with the thermoluminescence method

    International Nuclear Information System (INIS)

    Kumamoto, Yoshikazu

    1994-01-01

    Absorbed dose in radiation accidents can be estimated with the aid of materials which have the ability of dose recording and were exposed during the accidents. Quartz in bricks and tiles used to construct the buildings has the thermoluminescent properties. These materials exposed to radiations emit light when heated. Quartz and ruby have been used for the estimation of dose. The requirements for such dosemeters include; (1)the high kiln temperature at which all thermoluminescent energies accrued from natural radiations are erased. (2)the negligible fading of thermoluminescent energies after the exposure to radiations. (3)the determination of dose from natural radiations after the making of the matcrials. (4)the geometry of the place at which materials are collected. Bricks or tiles are crushed in the motar, sieved into sizes, washed with HF, HCl, alchol, aceton and water, and given with a known calibration dose. The pre-dose method and high-temperature method are used. In the former, glow curves with and without calibration dose are recorded. In the latter, glow peaks at 110degC with and without calibration dose are recorded after the heating of quartz up to 500degC. In this report, the method of the sample preparation, the measurement procedures and the results of dose estimation in the atomic bombing, iridium-192 and Chernobyl accident are described. (author)

  11. Personnel radiation monitoring by thermoluminescence dosimetry (2000-2001)

    International Nuclear Information System (INIS)

    Mi-Cho-Cho, Daw; Hla-Hla-Win, Daw; Thin-Thin-Kraing

    2001-01-01

    Thermoluminescence dosimetry service was introduced in 1991. Personnel who exposed directly or indirectly to radiation is monitored by thermoluminescent dosimeter. TL materials used for thermoluminescent dosimeter are in the form of thin disc. Personnel whole-body and extremity doses are measured by thermoluminescence dosimetry. The Harshaw Model 4500 TLD reader and Vinten 654E TLD reader are used for TLD evaluation. At present about 600 radiation workers are provided with TLD for routine monitoring. It was found that most personnel had received within permissible dose recommended by the International Commission on Radiological Protection (ICRP). (author)

  12. Electron beam energy monitoring using thermoluminescent dosimeters and electron back scattering

    International Nuclear Information System (INIS)

    Nelson, Vinod; Gray, Alison

    2013-01-01

    Periodic checks of megavoltage electron beam quality are a fundamental requirement in ensuring accurate radiotherapy treatment delivery. In the present work, thermoluminescent dosimeters (TLDs) positioned on either side of a lead sheet at the surface of a water equivalent phantom were used to monitor electron beam quality using the electron backscattering method. TLD100 and TLD100H were evaluated as upstream detectors and TLD200, TLD400 and TLD500 were evaluated as downstream detectors. The evaluation assessed the test sensitivity and correlation, long and short term reproducibility, dose dependence and glow curve features. A prototype of an in-air jig suitable for use in postal TLD dose audits was also developed and an initial evaluation performed. The results indicate that the TLD100-TLD200 combination provides a sensitive and reproducible method to monitor electron beam quality. The light weight and easily fabricated in-air jig was found to produce acceptable results and has the potential to be used by radiation monitoring agencies to carry out TLD postal quality assurance audits, similar to audits presently being conducted for photon beams. -- Highlights: ► Monitoring electron beam quality via electron backscattering was investigated. ► Different thermoluminescent materials were evaluated as detectors. ► A TLD100-TLD200 combination produced the most sensitive and reproducible results. ► An in-air jig was evaluated to allow measurements via postal dose audits

  13. Valores e Desenvolvimento Humano

    NARCIS (Netherlands)

    F. Comim (Flavio); A. Macedo de Jesus (Anderson); R.C.B Oliveira (Raissa); A. Davison (Anna); S. Galeno (Sabrina); A.C.V. Ribeiro (Ana)

    2010-01-01

    markdownabstractA primeira parte desse Relatório de Desenvolvimento Humano do Brasil 2009/2010 começa com a descrição de um amplo processo de consulta aberta à sociedade, denominada Brasil Ponto a Ponto, para a escolha do tema do relatório. A Campanha Brasil Ponto a Ponto teve por objetivo

  14. Performance of Harshaw 6600 thermo-luminescence dosimeter (TLD)

    African Journals Online (AJOL)

    Performance of Harshaw 6600 thermo-luminescence dosimeter (TLD) system for personal monitoring. ... Fading of 19 % of thermo-luminescence (TL) readout was observed in 90 days when TLD chips were stored at room temperature (~ 27º C). The TL sensitivities of chips in three holder types were close to that for Cs-137 ...

  15. Thermoluminescence in CVD diamond films: application to actinometric dosimetry

    International Nuclear Information System (INIS)

    Barboza-Flores, M.; Melendrez, R.; Chernov, V.; Castaneda, B.; Pedroza-Montero, M.; Gan, B.; Ahn, J.; Zhang, Q.; Yoon, S.F.

    2002-01-01

    Diamond is considered a tissue-equivalent material since its atomic number (Z=6) is close to the effective atomic number of biological tissue (Z=7.42). Such a situation makes it suitable for radiation detection purposes in medical applications. In the present work the analysis is reported of the thermoluminescence (TL) and dosimetric features of chemically vapour deposited (CVD) diamond film samples subjected to ultraviolet (UV) irradiation in the actinometric region. The TL glow curve shows peaks at 120, 220, 320 and 370 deg. C. The 120 and 370 deg. C peaks are too weak and the first one fades away in a few seconds after exposure. The overall room temperature fading shows a 50% TL decay 30 min after exposure. The 320 deg. C glow peak is considered to be the most adequate for dosimetric applications due to its low fading and linear TL behaviour as a function of UV dose in the 180-260 nm range. The TL excitation spectrum presents a broad band with at least two overlapped components around 205 and 220 nm. The results indicate that the TL behaviour of CVD diamond film can be a good alternative to the currently available dosemeter and detector in the actinometric region as well as in clinical and medical applications. (author)

  16. Thermoluminescence dosimetry in quality imaging in CR mammography systems

    International Nuclear Information System (INIS)

    Gaona, E.; Franco E, J.G.; Azorin N, J.; Diaz G, J.A.I.; Arreola, M.

    2006-01-01

    The aim of this work is to estimate the average glandular dose with Thermoluminescence Dosimetry (TLD) and comparison with quality imaging in CR mammography. For measuring dose, FDA and ACR use a phantom, so that dose and image quality are assessed with the same test object. The mammography is a radiological image to visualize early biological manifestations of breast cancer. Digital systems have two types of image-capturing devices, Full Field Digital Mammography (FFDM) and CR mammography. In Mexico, there are several CR mammography systems in clinical use, but only one CR mammography system has been approved for use by the FDA. Mammography CR uses a photostimulable phosphor detector (PSP) system. Most CR plates are made of 85% BaFBr and 15% BaFI doped with europium (Eu) commonly called barium fluoro halide. We carry out an exploratory survey of six CR mammography units from three different manufacturers and six dedicated x-ray mammography units with fully automatic exposure. The results show three CR mammography units (50%) have a dose that overcomes 3.0 mGy and it doesn't improve the image quality and dose to the breast will be excessive. The differences between doses averages from TLD system and dosimeter with ionization chamber are less than 10%. TLD system is a good option for average glandular dose measurement. (Author)

  17. Thermoluminescence sensitivity of ulexite after UV irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Topaksu, M., E-mail: mats@cu.edu.tr [Cukurova University, Arts-Sciences Faculty, Physics Department, 01330 Adana (Turkey); CIEMAT, Av. Complutense 22, 28040 Madrid (Spain); Correcher, V. [CIEMAT, Av. Complutense 22, 28040 Madrid (Spain); Garcia-Guinea, J. [Museo Nacional de Ciencias Naturales, (CSIC), C/José Gutiérrez Abascal 2, 28006 Madrid (Spain)

    2015-04-15

    Highlights: •UV-induced thermoluminescence emission of Turkish ulexite was studied. •There are three groups of components. •The UV exposures were performed at controlled temperatures. -- Abstract: The effects of UV radiation on the thermoluminescence (TL) properties of natural materials, in contrast to synthetic materials, have been scarcely studied. We report on the UV-induced thermoluminescence emission of a Turkish ulexite (NaCaB{sub 5}O{sub 6}(OH){sub 6}·5H{sub 2}O) that displays very complex TL glow curves, with at least three groups of components peaked at 130–140 °C, 240 °C and, 340 °C, wherein the last group is weaker. Such emission could be associated with structural changes in the lattice as well as alkali self-diffusion processes. The UV exposure performed at controlled temperatures (at room temperature (RT), 50 °C and 100 °C) produced a (i) different evolutions of the intensities of each maximum, which are directly related to the controlled thermal treatment; (ii) different intensity ratios among the groups of components; (iii) different activation energies (E{sub a}) (1.13 eV for RT, 0.99 eV for 50 °C and 0.49 eV for 100 °C) calculated using the initial rise method; and (iv) similar scattering values (12.4%, 8.2% and 12.8%), which were not a function of the controlled temperature. The thermal stability tests conducted on this borate at different temperatures, based on the T{sub stop} protocol, confirm the presence of a continuum in the distribution of the trap system with progressively increasing E{sub a} (from 0.60 to 0.90 eV)

  18. Reactor Gamma Heat Measurements with Calorimeters and Thermoluminescence Dosimeters

    DEFF Research Database (Denmark)

    Haack, Karsten; Majborn, Benny

    1973-01-01

    Intercomparison measurements of reactor γ-ray heating were carried out with calorimeters and thermoluminescence dosimeters. Within the measurement uncertainties the two methods yield coincident results. In the actual measurement range thermoluminescence dosimeters are less accurate than calorimet......Intercomparison measurements of reactor γ-ray heating were carried out with calorimeters and thermoluminescence dosimeters. Within the measurement uncertainties the two methods yield coincident results. In the actual measurement range thermoluminescence dosimeters are less accurate than...... calorimeters, but possess advantages such as a small probe size and the possibility of making simultaneous measurements at many different positions. Hence, thermoluminescence dosimeters may constitute a valuable supplement to calorimeters for reactor γ-ray heating measurements....

  19. Thermoluminescent response of LaAlO3:Pr

    International Nuclear Information System (INIS)

    Morales H, A.; Zarate M, J.; Azorin N, J.; Rivera M, T.

    2015-10-01

    In this study, the thermoluminescence response of doped lanthanum aluminate (LaAlO 3 ) with praseodymium ion (Pr) obtained by the Pechini method and drying by the spraying technique Spry Dryer was studied. The obtained powders were analyzed structurally by the X-ray diffraction technique; the morphological characterization was by the scanning electron microscopy technique. The obtained powders at 800 degrees C presented crystallinity and showed a Rhombohedral crystal structure, this phase was observed by X-ray diffraction patterns. Thermoluminescence response of LaAlO 3 :Pr showed a brightness curve with a peak centered at 157 degrees C. The sensitivity of the doped samples was improved about 90 times in comparison with the undoped sample. Thermoluminescence response in function of the wavelength showed a maximum at 230 nm, reproducibility of thermoluminescence response was ±50%. Also the fading in thermoluminescence response was studied. (Author)

  20. Method of analysis of asbestiform minerals by thermoluminescence

    Science.gov (United States)

    Fisher, Gerald L.; Bradley, Edward W.

    1980-01-01

    A method for the qualitative and quantitative analysis of asbestiform minerals, including the steps of subjecting a sample to be analyzed to the thermoluminescent analysis, annealing the sample, subjecting the sample to ionizing radiation, and subjecting the sample to a second thermoluminescent analysis. Glow curves are derived from the two thermoluminescent analyses and their shapes then compared to established glow curves of known asbestiform minerals to identify the type of asbestiform in the sample. Also, during at least one of the analyses, the thermoluminescent response for each sample is integrated during a linear heating period of the analysis in order to derive the total thermoluminescence per milligram of sample. This total is a measure of the quantity of asbestiform in the sample and may also be used to identify the source of the sample.

  1. An experimental system for thermoluminescent dosimetry

    International Nuclear Information System (INIS)

    Perry, K.E.G.; George, E.

    1965-08-01

    A thermoluminescent dosimeter (T.L.D.) reader has been developed for experimental investigations on the use of lithium fluoride for 'finger tip' dosimetry. The design of the reader is based on the maximum use of standard electronic units in the A.E.R.E. Type 2000 series but some new unit development has been necessary. The reader gives improved experimental facilities over present commercially-available designs. The technique for 'finger-tip' dosimetry is described and the initial experimental results are given. (author)

  2. Thermoluminescent analysis of CaSO{sub 4} composites activated with rare earths; Analise termoluminescente de compositos de CaSO{sub 4} ativado com terras raras

    Energy Technology Data Exchange (ETDEWEB)

    Junot, D.O.; Chagas, M.A.P.; Souza, D.N., E-mail: danilo.junot@hotmail.com, E-mail: mchagasfisica@gmail.com, E-mail: divanizi@ufs.br [Universidade Federal de Sergipe (UFS), Sao Cristovao, SE (Brazil). Departamento de Fisica

    2013-07-01

    Since the thermoluminescence started to be applied to the dosimetry of ionizing radiation in 1940 different materials detectors have been proposed, and one of the most common is CaSO{sub 4}. The motivation of this work was to produce crystals of CaSO{sub 4} doped with rare earth elements such as europium (Eu), neodymium (Nd) and thulium (Tm). It was also produced crystals of CaSO{sub 4}:Ag. The interest in the production of these materials was to investigate other methods of production of thermoluminescent materials. The results show that the CaSO{sub 4}:Tm is more suitable for use in the thermoluminescent dosimetry. Although not the most intense peak, the peak at 170 °C could be a dosimetric peak. Analyses showed that all samples have a TL response proportional to the dose absorbed. (author)

  3. Thermoluminescence method for detection of irradiated food

    Energy Technology Data Exchange (ETDEWEB)

    Pinnioja, S

    1998-12-31

    A method of thermoluminescence (TL) analysis was developed for the detection of irradiated foods. The TL method is based on the determination of thermoluminescence of adhering or contaminating minerals separated from foods by wet sieving and treatment with high density liquid. Carbon tetrachloride provided a suitable alternative for foods that form gels with water. Thermoluminescence response of minerals in a first TL measurement is normalised with a second TL measurement of the same mineral sample after calibration irradiation to a dose of 5 kGy. The decision about irradiation is made on the basis of a comparison of the two TL spectra: if the two TL glow curves match in shape and intensity the sample has been irradiated, and if they are clearly different it has not been irradiated. An attractive feature of TL analysis is that the mineral material itself is used for calibration; no reference material is required. Foods of interest in the investigation were herbs, spices, berries and seafood. The presence of minerals in samples is a criterion for application of the method, and appropriate minerals were found in all herbs, spices and berries. The most common minerals in terrestrial food were tecto-silicates - quartz and feldspars - which with their intense and stable thermoluminescence were well suited for the analysis. Mica proved to be useless for detection purposes, whereas carbonate in the form of calcite separated from intestines of seafood was acceptable. Fading of the TL signal is considerable in the low temperature part of the glow curve during a storage of several months after irradiation. However, spices and herbs could easily be identified as irradiated even after two years storage. Conditions for seafood, which is stored in a freezer, are different, and only slight fading was observed after one year. The effect of mineral composition and structure on TL was studied for feldspars. Feldspars originating from subtropical and tropical regions exhibit lower TL

  4. Thermoluminescence method for detection of irradiated food

    International Nuclear Information System (INIS)

    Pinnioja, S.

    1998-01-01

    A method of thermoluminescence (TL) analysis was developed for the detection of irradiated foods. The TL method is based on the determination of thermoluminescence of adhering or contaminating minerals separated from foods by wet sieving and treatment with high density liquid. Carbon tetrachloride provided a suitable alternative for foods that form gels with water. Thermoluminescence response of minerals in a first TL measurement is normalised with a second TL measurement of the same mineral sample after calibration irradiation to a dose of 5 kGy. The decision about irradiation is made on the basis of a comparison of the two TL spectra: if the two TL glow curves match in shape and intensity the sample has been irradiated, and if they are clearly different it has not been irradiated. An attractive feature of TL analysis is that the mineral material itself is used for calibration; no reference material is required. Foods of interest in the investigation were herbs, spices, berries and seafood. The presence of minerals in samples is a criterion for application of the method, and appropriate minerals were found in all herbs, spices and berries. The most common minerals in terrestrial food were tecto-silicates - quartz and feldspars - which with their intense and stable thermoluminescence were well suited for the analysis. Mica proved to be useless for detection purposes, whereas carbonate in the form of calcite separated from intestines of seafood was acceptable. Fading of the TL signal is considerable in the low temperature part of the glow curve during a storage of several months after irradiation. However, spices and herbs could easily be identified as irradiated even after two years storage. Conditions for seafood, which is stored in a freezer, are different, and only slight fading was observed after one year. The effect of mineral composition and structure on TL was studied for feldspars. Feldspars originating from subtropical and tropical regions exhibit lower TL

  5. Thermoluminescence dependence on the wavelength of monochromatic UV-radiation in Cu-doped KCl and KBr at room temperature

    Energy Technology Data Exchange (ETDEWEB)

    Perez R, A.; Piters, T.; Aceves, R.; Rodriguez M, R.; Perez S, R., E-mail: rperez@cifus.uson.mx [Universidad de Sonora, Departamento de Investigaciones en Fisica, Apdo. Postal 5-088, 83190 Hermosillo, Sonora (Mexico)

    2014-08-15

    Thermoluminescence (Tl) dependence on the UV irradiation wavelengths from 200 to 500 nm in Cu-doped KCl and KBr crystals with different thermal treatment has been analyzed. Spectrum of the Tl intensity of each material show lower intensity at wavelengths longer than 420 nm. The Tl intensity depends on the irradiation wavelength. Structure of the Tl intensity spectrum of each sample is very similar to the structure of its optical absorption spectrum, indicating that at each wavelength, monochromatic radiation is absorbed to produce electronic transitions and electron hole pairs. Thermoluminescence of materials with thermal treatment at high temperature shows electron-hole trapping with less efficiency. The results show that Cu-doped alkali-halide materials are good detectors of a wide range of UV monochromatic radiations and could be used to measure UV radiation doses. (Author)

  6. Authenticity test in ceramics and archaeological figures by thermoluminescence

    International Nuclear Information System (INIS)

    Ramirez L, A.; Schaaf, P.; Filloy, L.

    1999-01-01

    At present exists quite a lot of false archaeological pieces which provokes doubts about the legitimacy of the pieces. In this work it is presented the Authenticity test by Thermoluminescence realized at the urn of the goddess 13 serpent of the zapotec culture of Oaxaca which is exposed in Mexico City. The original piece contains crystalline structures which present hardly the thermoluminescence phenomena by the presence of 238 U, 232 Th, and 40 K getting with this the form and intensity of the natural thermoluminescence curve of an archaeological piece which shows a Tl peak and allows to know so if it was made recently or not. (Author)

  7. The natural thermoluminescence of meteorites. VI - Carbon-14, thermoluminescence and the terrestrial ages of meteorites

    Science.gov (United States)

    Benoit, P. H.; Jull, A. J. T.; Mckeever, S. W. S.; Sears, D. W. G.

    1993-01-01

    A relationship is noted between the natural thermoluminescence (TL) levels and the C-14-derived terrestrial ages for meteorite finds from the U.S. Prairie States and Roosevelt County, NM; those in the Sahara are also in accord with calculated TL decay curves, for 'storage' temperatures equal to the approximate average annual temperatures at individual sites. This discussion is limited to the empirical correspondence between the two methodologies, and to theoretical decay curves for a single 'average' ordinary chondrite.

  8. Thermoluminescence properties of AlN ceramics

    DEFF Research Database (Denmark)

    Trinkler, L.; Christensen, P.; Agersnap Larsen, N.

    1998-01-01

    The paper describes thermoluminescence (TL) properties of AlN:Y2O3 ceramics irradiated with ionising radiation. A high TL sensitivity of AlN:Y2O3 ceramics to radiation encouraged a study of the AlN ceramics for application as a dosimetric material. The paper presents experimental data on: glow...... curve, emission spectrum, dose response, energy dependence, influence of heating rate and fading rate. The measured TL characteristics were compared with those of well-known, widely used TLDs, i.e. LiF:Mg,Ti, LiF:Mg,Cu,P and Al2O3:C. It is concluded that AlN:Y2O3 ceramics showing a radiation sensitivity...

  9. Thermoluminescent dosimetric properties of Descalvado sand

    International Nuclear Information System (INIS)

    Teixeira, M.I.; Caldas, L.V.E.

    2006-01-01

    Sand samples proceeding from Descalvado, Sao Paulo, were studied with regard to their dosimetric properties using the thermoluminescence technique (TL) for high doses. These sand samples present steady physical and chemical characteristics to the end items, and they are used in the glass industry and for casting. The TL curves of the samples were obtained after an irradiation at the Gamma-Cell system ( 60 Co), of IPEN. The glow curves present two peaks at 80 C and 220 C approximately. Calibration curves were obtained for doses between 50 Gy and 5 kGy. The results indicate that the sand samples can be used for high-doses dosimetry in several areas of applications of ionizing radiation. (Author)

  10. Thermoluminescent dosimetric properties of Descalvado sand

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, M.I.; Caldas, L.V.E

    2006-07-01

    Sand samples proceeding from Descalvado, Sao Paulo, were studied with regard to their dosimetric properties using the thermoluminescence technique (TL) for high doses. These sand samples present steady physical and chemical characteristics to the end items, and they are used in the glass industry and for casting. The TL curves of the samples were obtained after an irradiation at the Gamma-Cell system ({sup 60} Co), of IPEN. The glow curves present two peaks at 80 C and 220 C approximately. Calibration curves were obtained for doses between 50 Gy and 5 kGy. The results indicate that the sand samples can be used for high-doses dosimetry in several areas of applications of ionizing radiation. (Author)

  11. Thermoluminescence of natural and synthetic diopside

    Energy Technology Data Exchange (ETDEWEB)

    Cano, N.F. [Institute of Physics, University of Sao Paulo, Rua do Matao, Travessa R, 187, CEP 05508-900 Sao Paulo (Brazil)], E-mail: nilocano@dfn.if.usp.br; Yauri, J.M. [Institute of Physics, University of Sao Paulo, Rua do Matao, Travessa R, 187, CEP 05508-900 Sao Paulo (Brazil); University of Alas Peruanas, Environmental Engineering, Arequipa (Peru); Watanabe, S. [Institute of Physics, University of Sao Paulo, Rua do Matao, Travessa R, 187, CEP 05508-900 Sao Paulo (Brazil); Mittani, J.C.R. [Department of Physics, Oklahoma State University, Stillwater, OK 74078-3072 (United States); Blak, A.R. [Institute of Physics, University of Sao Paulo, Rua do Matao, Travessa R, 187, CEP 05508-900 Sao Paulo (Brazil)

    2008-07-15

    Diopside, a natural silicate mineral of formula CaMgSi{sub 2}O{sub 6}, has been investigated concerning its thermoluminescence (TL) and electron paramagnetic resonance (EPR) properties. Glow curves and TL vs. {gamma}-dose were obtained irradiating natural samples to additional dose varying from 50 to 10,000 Gy. Except for a 410 deg. C peak found in the Al-doped artificial diopside, all the other peaks grow linearly with radiation dose, but saturate beyond {approx}1 kGy. To investigate high-temperature effect before irradiation, measurements of TL intensity in samples annealed at 500-900 deg. C and then irradiated to 1 kGy {gamma}-dose were carried out. Also the TL emission spectrum has been obtained. To compare with natural diopside, a synthetic pure polycrystal was produced and further those doped with iron, aluminum and manganese were also produced.

  12. Identification of irradiated food by thermoluminescent method

    International Nuclear Information System (INIS)

    Vo Van Thuan; Pham Quang Vinh; Tran Manh Hung; Dang Thanh Luong; Pham Quang Dien

    1990-01-01

    Thermoluminescent (TL) effect of irradiated dried food was observed by using the TL apparatus TOLEDO. Clear difference of TL intensity between irradiated sample and reference was found for chilies, black pepper, turmeric finger powder and gram green. For chilies powder and black pepper, TL effect was investigated in dependence on increasing absorbed dose from 0.5 to 20 kGy and fading effect was studied during storage time up to third month. When black pepper has linear dependence on dose up to 20 kGy, chilies effect catches a saturation at dose higher 5 kGy. TL effect was found very small after sample's washing, which shows an important role of inorganic impurity in TL effect. (author). 7 refs, 3 figs, 2 tabs

  13. Environmental radiation studies relevant to thermoluminescence dating

    International Nuclear Information System (INIS)

    Murray, A.S.; Bowman, S.G.E.; Aitken, M.J.

    1980-01-01

    To determine the age of a potsherd by the thermoluminescence (TL) technique, one must have an accurate knowledge of the cosmic and environmental gamma dose rate in quartz. This is obtained by leaving a sensitive TL dosimeter buried as near as possible to the position from which the sherd was removed. The ratios of the response of a quartz-like dosimeter to those of CaF 2 and LiF have been measured. This experiment used a 1-m cube of concrete containing 3000 ppM of uranium and its daughters. Smaller, less active matrixes of 40 K and thorium and its daughters have also been constructed. A means of making direct dose-rate determinations when the site context remains but burial of a dosimeter is impractical was developed using a NaI(Tl) system. The equipment was field tested on approx. 40 Peruvian archaeological sites, and results are compared with CaF 2 measurements

  14. Thermoluminescent dosimetry in veterinary diagnostic radiology

    International Nuclear Information System (INIS)

    Hernández-Ruiz, L.; Jimenez-Flores, Y.; Rivera-Montalvo, T.; Arias-Cisneros, L.; Méndez-Aguilar, R.E.; Uribe-Izquierdo, P.

    2012-01-01

    This paper presents the results of Environmental and Personnel Dosimetry made in a radiology area of a veterinary hospital. Dosimetry was realized using thermoluminescent (TL) materials. Environmental Dosimetry results show that areas closer to the X-ray equipment are safe. Personnel Dosimetry shows important measurements of daily workday in some persons near to the limit established by ICRP. TL results of radiation measurement suggest TLDs are good candidates as a dosimeter to radiation dosimetry in veterinary radiology. - Highlights: ► Personnel dosimetry in laboratory veterinary diagnostic was determined. ► Student workplaces are safe against radiation. ► Efficiency value of apron lead was determined. ► X-ray beams distribution into veterinarian laboratory was measured.

  15. Mechanism of thermoluminescence in Vietnam natural quartz

    International Nuclear Information System (INIS)

    Tran Ngoc; Nguyen Manh Son; Phan Tien Dung; Trinh The Cuong; Nguyen Trong Thanh; Vu Xuan Quang

    2006-01-01

    Thermoluminescence properties of the Vietnam's natural quartz showed a number of peaks in the glow curve at 100 o C and 325 o C. the TL emission spectrum mainly consisted of three broad emission bands located at around 380 nm (3.26 eV), 470 nm (2.64 eV) and 610 nm (2.03 eV). These peaks were attributed to the [H 3 O 4 ] 0 hole centres, [AlO 4 ] 0 centres and E ' centres (oxygen vacancy), respectively. The main effect of blue light (450 nm) exposure was the appearance of the distinctive 110 o C TL peak and a reduction of the 325 o C TL peak. The observed relationship between TL intensity and illumination wavelength was consistent with those reported in the work of Botter-Jensen et al. (1994b) who suggested a linear relationship between logarithm of intensity and the photon energy. (author)

  16. Ultraviolet dosimetry using thermoluminescent phosphors - an update

    International Nuclear Information System (INIS)

    Nagpal, J.S.

    1998-04-01

    Intrinsic response of various thermoluminescent (TL) materials such as CaSO 4 (Dy, Eu, Mn, Sm, Tb, or Tm), LiF (Mg, Cu, P), Mg 2 SiO 4 :Tb, CaF 2 :Dy, CaF 2 :Tb, ThO 2 :Tb and Al 2 O 3 (Si, Ti); cathodoluminescent phosphors Y 3 Al 5 O 12 :Ce, Y 3 Al 5 O 12 :Tb and Y(V,P)O 4 :Eu; and fluorescent lamp phosphors calcium halophosphate (Mn,Sb) and Ce Mg aluminate (Eu, Tb) to ultraviolet (UV) radiations has been studied. Intrinsic TL response of most of the phosphors is rate (radiant flux) dependent. For the first time, UV response of the materials is reported for a fixed total radiant energy (total UV dose), at a single radiant flux (260 μW.cm -2 ), for an appropriate comparison. A wide range of UV sensitivity is observed. Studies conducted using UV radiation from two unfiltered low pressure mercury lamps show significant differences in glow curves, as compared to those obtained with nearly monochromatic UV radiations. Photons of wavelength 365 nm induce bleaching of TL induced by 254 nm photons, in most of the materials. Sequential/tandem exposures to 254 nm and 365 nm photons have yielded new but alarming results in CaF 2 :Tb. Preferential induction and bleaching of specific TL glow peaks by 365 nm and 254 nm photons are interesting characteristics discovered in CaSO 4 :Eu. Photoluminescence studies of Tb 3+ and Eu 3+ activated phosphors have augmented the inferences drawn from the bleaching effects produced by 365 nm photons. Earlier work carried out on phototransferred thermoluminescence of CaSO 4 :Dy-teflon dosimeters, TLD-100, Mg 2 SiO 4 :Tb and Al 2 O 3 (Si,Ti) has also been reviewed. (author)

  17. Historical note: thermoluminescent dosimetry (LiF) 1950-51

    International Nuclear Information System (INIS)

    Heckelsberg, L.F.

    1980-01-01

    The early history of thermoluminescent dosimetry has not been adequately described and one of the first workers in this field takes this opportunity to record more fully the history of the period. (author)

  18. Thermoluminescence in alkali halides irradiated at 80K

    International Nuclear Information System (INIS)

    Jimenez de Castro, M.

    1978-01-01

    The thermoluminescence, the thermally stimulated currents and the thermal stability of the F centres induced in pure NaCl and KC1 crystals by X irradiation at 80K have been studied in detail, in the range between 80 and 300K. The thermoluminescent processes induced by illumination at 80K with F light in samples previously irradiated at room temperature has also been studied. It has been clearly observed the existence of thermoluminescent processes due to electrons and holes thermally released from traps, in which the F centres are not involved. The existence of hole-F centre recombination has not been observed. There are several thermoluminescent processes in both materials which are scribed to the recombination of F centres with mobile interstitial halogen atoms thermally released from traps, which are likely monovalent impurities in this temperature interval. The light emitting stage in these processes is originated by the formation of self trapped excitons. (Author) 66 refs

  19. Natural dose level determination at Johor State with thermoluminescence dosimetry

    International Nuclear Information System (INIS)

    Ahmad Termizi Ramli; Yusof Jasman

    1995-01-01

    This paperwork presented the results of using thermoluminescence dosimetry (TLD) method in measuring background dose level, which is done at State of Johor, South Malaysia. The problems faced also discussed

  20. Storage Telemetry of Radionuclide Tracers by Implantable Thermoluminescent Dosimeters

    DEFF Research Database (Denmark)

    Bojsen, J.; Møller, U.; Christensen, Poul

    1977-01-01

    A storage telemetrical method using thermoluminescent (TL) dosimeters for long-term measurements of incorporated radioactive substances in unrestrained rats has been developed. The system has been used in combination with radiotelemetrical registration of the circadian temperature rhythm. By sequ...

  1. Characteristics of thermoluminescent dosemeter and their recent trend

    International Nuclear Information System (INIS)

    Yook, C.C.

    1979-01-01

    Principles, characteristics, and recent trends of application of the thermoluminescent dosemeter are extensively reviewed. The sensitivity, reproducibility, fluctuation range and other practical details are also examined and discussed. (author)

  2. Evaluation of the thermoluminescent detector answers of CaSO{sub 4}:Dy, LiF:Mg,Ti and micro LiF:Mg,Ti in photon clinical beams dosimetry using water simulator; Avaliacao da resposta de detectores termoluminescentes de CaSO4:Dy, LiF:Mg,Ti e microLiF:Mg,Ti na dosimetria de feixes clinicos de fotons utilizando simulador de agua

    Energy Technology Data Exchange (ETDEWEB)

    Matsushima, Luciana C.; Veneziani, Glauco R.; Campos, Leticia L., E-mail: lmatsushima@usp.b, E-mail: veneziani@ipen.b, E-mail: lcrodri@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (GMR/IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Gerencia de Metrologia das Radiacoes; Sakuraba, Roberto K.; Cruz, Jose C. da, E-mail: rsakuraba@einstein.b, E-mail: jccruz@einstein.b [Sociedade Beneficente Israelita Brasileira, Sao Paulo, SP (Brazil). Hospital Albert Einstein (HAE)

    2011-10-26

    This paper perform the comparative study of thermoluminescent answer of calcium sulfate dosemeter doped with dysprosium (DaSO{sub 4}:Dy) produced by the IPEN, Sao Paulo, with answer of lithium fluoride dosemeters doped with magnesium and titanium (LiF:Mg, Ti) in the dosimetry of clinical beams of photons (6 and 15 MV) by using water simulator object. Dose-answer curves were obtained for gamma radiation of cobalt-60 in the air and in conditions of electronic equilibrium (plate of PMMA), and clinical photons of CLINAC model 2100C accelerators of the two evaluated hospitals: Hospital das Clinicas of the Faculty of Medicine of Sao Paulo university and Hospital Albert Einstein. It was also evaluated the sensitivity and reproduction of the three dosemeters

  3. Neutron dosimetry: problems, solutions, prospects and the role of trace detectors

    International Nuclear Information System (INIS)

    Fernandez, F.

    2009-10-01

    It is present in schematic way, the origin of the neutrons; their interaction with matter, until its application in the field of dosimetry. It describes some measuring instruments based on thermoluminescence dosimetry, some activation detectors and trace detectors. Finally, it summarizes the work in neutron dosimetry have been carried out at the Autonomous University of Barcelona. (Author)

  4. Thermoluminescence, luminescence optically stimulated and creation of defects in alkaline halogenides contaminated with Europium

    International Nuclear Information System (INIS)

    Barboza F, M.

    1999-01-01

    The alkaline halogenides have been subject matter of investigations related with the search of sensor materials for X-ray bidimensional images or optical memories. The understanding of the damage formation processes generated by ionizing and non-ionizing radiations is important for the correct design of devices that working as detectors and dosemeters of both type of radiations. In this work we present the investigation results related with the defects produced by the ionizing radiation type X and ultraviolet light in the range of 200-360 nm in crystals of KCl: Eu 2+ and KBr:Eu 2+ . It is examined the thermoluminescence and luminescence spectra with the purpose of identifying the exciton processes, owing to the excitation of the halogenide ions in which the primary defects correspond to the F and H centers. It has been found that the 400-600 nm emission is associated with the luminescence type that in his turn can be associated with autotrapped excitons perturbed by the impurity. On the other hand, it is examined the emission spectra of the luminescence optically stimulated in crystals of KBr: Eu 2+ and KCl: Eu 2+ finding too that such materials would be used as optical memories susceptible of to store information, and through of photostimulation to read this. It was determined that the F centers participate in the luminescence optically stimulated in these crystals, as well as too in the recombination processes responsible by the thermoluminescent emission. (Author)

  5. Evaluation of new and conventional thermoluminescent phosphors for environmental monitoring using automated thermoluminescent dosimeter readers

    International Nuclear Information System (INIS)

    Rathbone, B.A.; Endres, A.W.; Antonio, E.J.

    1994-01-01

    In recent years there has been considerable interest in a new generation of super-sensitive thermoluminescent (TL) phosphors for potential use in routine personnel and environmental monitoring. Two of these phosphors are evaluated in this paper for selected characteristics relevant to environmental monitoring, along with two conventional phosphors widely used in environmental monitoring. The characteristics evaluated are light-induced fading, light-induced background, linearity and variability at low dose, and the minimum measurable dose. These characteristics were determined using an automated commercial dosimetry system and routine processing protocols. Annealing and readout protocols for each phosphor were optimized for use in a large-scale environmental monitoring program

  6. Study and determination of thermoluminescent properties of a new dosemeter based on α -Al2O3:C

    International Nuclear Information System (INIS)

    Rivera Montalvo, T.

    1993-01-01

    Study and determination of the thermoluminescent properties of a new dosimeter based on α -Al 2 O 3 :C. Dosimetric characteristics studied were: glow curve structure, sensitivity, reproducibility, TL response as function of dose, and fading. Each experimental data point represents the average value of at least five measurements. The new detectors exhibited two peaks in its glow curve at 383 and 493 K. The low temperature peak decayed at room temperature in a few hours. Sensitivity of α -Al 2 O 3 :C detectors to gamma radiation per unit of absorbed dose was 3 times that of LiF:Mg, Cu, P and 11 times that of CaSO 4 : Dy + PTFE; the last two detectors possess characteristics which make them appropriate for diverse applications in the field of radiation dosimetry, specially for environmental measurements. (Author)

  7. Thermoluminescent and impedimetric studies on irradiated foodstuffs

    International Nuclear Information System (INIS)

    Mamoon, A.M.

    2000-01-01

    Several brands of different spices and milk powders were irradiated with relatively high doses of gamma radiation. Glow curves were produced upon heating these irradiated foodstuffs only. Study of the obtained spices glow curves revealed that the magnitude of these curves depends upon the dose received while the shape of the curves remains generally the same for the different doses and for the different spices. Previous studies had shown that the obtained thermoluminescence (TL) is due to dust particles carried by the spices. The TL studies show, furthermore, that different brands of the same spice are apparently contaminated with different amounts of dust or soil. The obtained TL from irradiated milk powders is apparently due to its mineral content. Different milk powders gave TL curves of different magnitudes for the same dose depending upon the milk brand. Impedimetric studies carried out irradiated potatoes show changes in impedance amplitude and phase angle. The results support earlier work on the use of TL to differentiate between irradiated and control foodstuffs, to assess the extent of spices contamination with soil-which perhaps reflects hygienic care-and that impedimetric measurements can distinguish irradiated from control potatoes

  8. Thermoluminescence of zircon: a kinetic model

    CERN Document Server

    Turkin, A A; Vainshtein, D I; Hartog, H W D

    2003-01-01

    The mineral zircon, ZrSiO sub 4 , belongs to a class of promising materials for geochronometry by means of thermoluminescence (TL) dating. The development of a reliable and reproducible method for TL dating with zircon requires detailed knowledge of the processes taking place during exposure to ionizing radiation, long-term storage, annealing at moderate temperatures and heating at a constant rate (TL measurements). To understand these processes one needs a kinetic model of TL. This paper is devoted to the construction of such a model. The goal is to study the qualitative behaviour of the system and to determine the parameters and processes controlling TL phenomena of zircon. The model considers the following processes: (i) Filling of electron and hole traps at the excitation stage as a function of the dose rate and the dose for both (low dose rate) natural and (high dose rate) laboratory irradiation. (ii) Time dependence of TL fading in samples irradiated under laboratory conditions. (iii) Short time anneali...

  9. Photoinduced emission and thermoluminescence in topaz

    International Nuclear Information System (INIS)

    Dantas, Samuel Cesar; Giroldo Valerio, Mario Ernesto; Couto dos Santos, Marcos Antonio; Souza, Divanizia do Nascimento

    2006-01-01

    Topaz has been demonstrated to be useful for dosimetric application. This mineral exhibits a satisfactory thermoluminescent (TL) response to radiation. In previous studies we analyzed the natural topaz samples from Minas Gerais, Brazil, by TL, infrared and X-ray diffraction techniques, with the aim of obtaining an explanatory model for the process of light emission of this mineral. Thermal treatments and irradiations do not produce significant changes in the TL emission. TL spectra exhibit a broad band with a maximum TL intensity at 420 nm in all the samples. In order to better understand the physical processes involved in the light emission of the topaz, we analyzed the photoinduced fluorescence of natural (as received) and thermally treated samples in powder form. The photoinduced emission of topaz was found to be similar to that of other silicates. In the UV-visible range there are intense emission bands between 350 and 550 nm, with a maximum intensity at 435 nm. The intensities are different for each sample

  10. Thermoluminescence properties of irradiated chickpea and corn

    Energy Technology Data Exchange (ETDEWEB)

    Necmeddin Yazici, A. [University of Gaziantep, Department of Engineering, Physics, 27310 Gaziantep (Turkey)], E-mail: yazici@gantep.edu.tr; Bedir, Metin; Bozkurt, Halil [University of Gaziantep, Department of Engineering, Physics, 27310 Gaziantep (Turkey); Bozkurt, Hueseyin [University of Gaziantep, Department of Food Engineering, 27310 Gaziantep (Turkey)

    2008-02-15

    A study was carried out to establish a detection method for irradiated chickpea and corn by thermoluminescence (TL) method. The leguminous were packed in polyethylene bags and then the packets were irradiated at room temperature at different doses by {sup 60}Co gamma source at 1, 4, 8 and 10 kGy. Minerals extracted from the leguminous were deposited onto a clean aluminum disc and TL intensities of the minerals were measured by TL. It was observed that the extracted samples from both leguminous exhibit good TL Intensity and the TL intensity of glow curves of them increased proportionally to irradiation doses. The TL glow curve of both irradiated leguminous presents a single broad peak below 400 degC. The TL trapping parameters glow peaks were estimated by the additive dose (AD), T{sub m}(E{sub a})-T{sub stop} and computerized glow curve deconvolution (CGCD) methods. The fading characteristics of glow curves were also recorded up to 6 months.

  11. Evaluation of environmental monitoring thermoluminescent dosimeter locations

    International Nuclear Information System (INIS)

    Kinnison, R.

    1992-12-01

    Geostatistics, particularly kriging, has been used to assess the adequacy of the existing NTS thermoluminescent dosimeter network for determination of environmental exposure levels. (Kriging is a linear estimation method that results in contour plots of both the pattern of the estimated gamma radiation over the area of measurements and also of the standard deviations of the estimated exposure levels.) Even though the network was not designed as an environmental monitoring network, ft adequately serves this function in the region of Pahute and Rainier Mesas.. The Yucca Flat network is adequate only if a reasonable definition of environmental exposure levels is required; R is not adequate for environmental monitoring in Yucca Flat if a coefficient of variation of 10 percent or less is chosen as the criterion for network design. A revision of the Yucca Flat network design should be based on a square grid pattern with nodes 5000 feet (about one mile) apart, if a 10 percent coefficient of variation criterion is adopted. There were insufficient data for southern and western sections of the NTS to perform the geostatistical analysis. A very significant finding was that a single network design cannot be used for the entire NTS, because different areas have different variograms. Before any design can be finalized, the NTS management must specify the exposure unit area and coefficient of variation that are to be used as design criteria

  12. Thermoluminescence sensitivity of daily use materials

    International Nuclear Information System (INIS)

    Correcher, V.; Sanchez M, L.; Delgado, A.; Garcia G, J.; Rivera M, T.

    2007-01-01

    Full text: Both radiation accidents and radiological terrorism could be evaluated with the help of environmental materials that can act as potential- dosimeters. The luminescence of ceramic materials (bricks, tiles or insulators) has been successfully investigated to be applied in the field of retrospective dosimetry, however, studies on the luminescence emission of some other domestic or-industrial materials have been scarcely achieved. Several.of these daily-use material$ such as: chemicals used in laundry (mixture of sodium polyphosphate and sodium sulphate), vitreous materials (windows, glasses, etc., made of aluminosilicates), cellular phone chips (made of doped silicon), common salt (sodium chloride), dental crowns (mainly made of silicates), construction plates (marble and granite) or gems (corundum or sapphire, Al 2 O 3 ; charoite, K 5 Ca 8 (Si 6 O 15 )(Si 2 O 7 )(Si 4 O 8 ) (OH) 3H 2 O, pectolite NaCa 2 Si 3 O 8 (OH), etc.), exhibit a reasonable sensitivity to radiation and high reproducibility of the thermoluminescence (TL) emission. The features of these materials allow us to think that could be used for dose reconstruction in areas affected by a radiological accident where do not necessarily conventional dosimetric systems can be ready. This work focuses on the study of (i) the chemical and structural characterisation of some of the aforementioned materials by means of X-ray diffraction, electron probe microanalysis (EPMA) and X-ray fluorescence (XRF) and (ii) the radiation sensitivity based on their TL properties. (Author)

  13. Thermoluminescent and optical processes in alkaline halogenides dosemeters contaminated with Europium; Procesos opticos y termoluminiscentes en dosimetros de halogenuros alcalinos contaminados con Europio

    Energy Technology Data Exchange (ETDEWEB)

    Barboza F, M.; Melendrez, R.; Castaneda, B.; Pedroza M, M.; Chernov, V.; Perez S, R.; Aceves, R. [Centro de Investigacion en Fisica, Universidad de Sonora, A.P. 5-088, 83190 Hermosillo, Sonora (Mexico)

    2000-07-01

    Recent research results are presented about the properties of the optical processes of photo transferred thermoluminescence (TLFT), optical whitening (BO), thermoluminescence induced by light (TLL) and its effect in the thermoluminescent curve (Tl) produced by ionizing and non-ionizing radiation. The systematic analysis of all these processes, acquires a singular importance due that actually the alkaline halogenide crystals are object of intense investigations which analyse their potential applications as detectors and radiation dosemeters through stimulated optical luminescence techniques or thermoluminescence. The obtained data show that the Tl curve of material with this nature can be enormously affected by exposure of phosphorus to the environmental light or UV. This is in part due to liberation processes of charge bearers are shouted and makes a subsequent trapping in less temperature traps; at the same time that induce changes in the intensity of determined Tl bands. Additionally, also it is observed that mentioned phenomena are related as with wavelength of incident light as of the illumination time. Finally, the obtained information allows to conclude that although the illumination effect is extremely complex, it is associated and can be explained mainly with phenomena that implicate the electrons excitation trapped in form of F centers and trapping mechanisms or radioactive and non-radioactive recombination. (Author)

  14. Obtention of a thermoluminescent material for dosimetry of ionizing radiation

    International Nuclear Information System (INIS)

    Gonzalez M, P.R.

    1990-01-01

    The thermoluminescent dosemeters are small crystals which suffer changes in their structure by the radiation effect, being displaced the electrons toward higher energy levels. On heating the previously irradiated crystals, the electrons come back to their base state emitting light photons. The light quantity emitted is proportional to the received radiation dose. The light quantity emitted is proportional to the received radiation dose. The lithium fluoride is one of the thermoluminescent materials considered as tissue equivalents by having a low effective atomic number (Z ef ). At present, the more used commercial product used of this type is the TLD-100*. In this work the obtained results in the preparation of the lithium fluoride thermoluminescent material are presented. This is activated with magnesium (Mg) and titanium (Ti), which we have labelled as: LiF: Mg, Ti. The results from the tests performed for verifying his thermoluminescent properties are presented too, as powder form as in pellets form. These tests were performed in simultaneous form with TLD-100 samples, which is considered as reference. The LiF: Mg, Ti thermoluminescent material manufactured in the ININ presents similar dosimetric characteristics to those ones of the TLD-100. Therefore being able to replace the imported dosemeters. * (TLD-100 is a commercial trademark registered by Harshaw/Filtrol (US) for LiF: Mg, Ti Tl dosemeters) (Author)

  15. Application of a thermoluminescence method for detection of irradiated spices

    Energy Technology Data Exchange (ETDEWEB)

    Gastelum, S.; Osuna, I.; Melendrez, R.; Cruz-Zaragoza, E.; Chernov, V.; Calderon, T.; Barboza-Flores, M

    2002-07-01

    Food irradiation is extremely effective at reducing food-borne illness as well as losses caused by infestation and contamination. Despite the well-established regulations that permit irradiation to control pathogens in spices, there are no widespread methods to detect previously irradiated food. Therefore, it has become necessary to develop new detection and dose determination methods for food subjected previously to irradiation. The present work deals with the application of the thermoluminescence (TL) phenomenon to detect irradiated spices. The process is based upon the thermoluminescence properties exhibited by the polymineral content of the irradiated specimen. After separating the organic material, it is possible to extract some polymineral substances that are suitable for thermoluminescence analysis due to interaction of the spice to ionising radiation. The method was successfully applied to examine irradiated and non-irradiated paprika of Mexican origin. The spice was irradiated with gamma rays at doses of 5, 10 and 15 kGy. The separated thermoluminescent polymineral was found to be composed mainly of quartz and feldspar. The thermoluminescence glow curve of the irradiated specimen shows a side band peaked 228, 268 and 336 deg. C, resembling pretty much the combined TL of quartz and feldspars. The method allows for the determination of the retrospective dose exposure. (author)

  16. Thermoluminescence of thin films deposited by laser ablation

    International Nuclear Information System (INIS)

    Escobar A, L.; Camps, E.; Arrieta, A.; Romero, S.; Gonzalez, P.R.; Olea M, O.; Diaz E, R.

    2003-01-01

    Materials in thin film form have received great attention in the last few years mainly because of their singular properties, which may differ significantly from their bulk attributes making them attractive for a wide variety of applications. In particular, thermoluminescence (Tl) properties of thin films have been studied recently owing to their potential applications in detection for both ionizing and non ionizing radiation. The aim of the present work is to report the synthesis and characterization of C Nx, aluminum oxide and titanium oxide thin films. Thermoluminescence response of the obtained thin films was studied after subject thin films to UV radiation (254 nm) as well as to gamma radiation (Co-60). Thermoluminescence glow curves exhibited a peak centered at 150 C for CN x whereas for titanium oxide the glow curve shows a maximum peaking at 171 C. Characterization of the physical properties of the deposited materials is presented. (Author)

  17. Effect of particle size on the thermoluminescent response of hydroxyapatite

    International Nuclear Information System (INIS)

    Barrera V, A.; Zarate M, J.; Contreras, M. E.; Rivera M, T.

    2016-10-01

    We present the study of the structural characterization and the thermoluminescent response of the hydroxyapatite as a function of the calcination temperature and the effect of the particle size. For precipitation synthesis, calcium nitrate (Ca(NO 3 ) 2 and dibasic ammonium phosphate ((NH 4 ) 2 HPO 4 ) were used as precursors and ammonium hydroxide (NH 4 OH) as a ph controlling agent. The characterization of the samples was carried out by the techniques of X-ray diffraction, scanning electron microscopy and infrared spectroscopy. The powders obtained are composed of hydroxyapatite, with a different degree of dehydroxylation. The thermoluminescent characterization indicates that at higher calcination temperature there is a higher thermoluminescent response, the calcined powders at 1300 degrees Celsius show a very well defined brightness curve with a higher intensity, with its maximum intensity located at a temperature of 210 degrees Celsius, which indicates that this material can be used as a dosimeter. (Author)

  18. Thermoluminescence of Zn O thin films deposited by chemical bath

    International Nuclear Information System (INIS)

    Camacho A, M. C.; Cruz V, C.; Bernal H, R.; Berman M, D.; Castano M, V. M.

    2015-10-01

    Full text: Zn O films on Si were synthesized using a deposition method by chemical bath and thermally treated at 900 degrees C for 12 h in air. The morphological characterization by scanning electron microscopy reveals that uniform films were obtained. To investigate the thermoluminescent properties of the films were exposed to irradiation with beta particles with doses in the range from 0.5 to 128 Gy. The brightness curves obtained using a heating rate of 5 degrees C have two peaks, one at 124 and another at 270 degrees C, and a linear dependence of the integrated thermoluminescence as a function of dose. The second maximum reveals the existence of localized trapping states of potential utility in thermoluminescent dosimetry. (Author)

  19. Temperature distribution in thermoluminescence experiments. Pt. 1

    International Nuclear Information System (INIS)

    Betts, D.S.; Couturier, L.; Khayrat, A.H.; Luff, B.J.; Townsend, P.D.

    1993-01-01

    In a typical thermoluminescence experiment, a sample rests on a metallic strip which is heated in a controlled fashion so that the strip temperature rises linearly with time. Thermal contact is improved by the use of an inert exchange gas, usually argon. With this procedure, samples of interest emit light spectra of low intensity as electrons escape from traps. The technique is applied, for example, to dating of artefacts or geological materials, to radioactive dosimetry, and to the characterization of optical materials. In this paper we present data which show that it is unsafe to make the common assumption that, during ramping, the light-emitting parts of the sample have the same temperature as the heating strip. We have performed experiments designed to demonstrate sizeable temperature differences. This is important where data from different laboratories are compared and we conclude that practitioners should routinely take note of the following points. Firstly, ramping rates should be as low as possible consistent with the optical sensitivity available (there is a trade-off between the two, but temperature differences are likely to be important where ramping rates exceed 5 K s -1 ). Secondly, it is advisable to use helium as exchange gas rather than the more usual argon, because it is a much better conductor of heat. Thirdly, users should do a few basic thermal experiments with their apparatus so that, with the aid of formulae given in the paper which follows this one, they can make corrections where these are important. This is the first of a linked pair of papers on this subject; it is primarily about experimental results, while the second (following) paper offers some theory which can be applied. (author)

  20. Thermoluminescence studies on plant seeds of different radiosensitivity

    International Nuclear Information System (INIS)

    Yamaguchi, Hikoyuki; Eguchi, Hoshio; Koizumi, Yoshinobu.

    1975-01-01

    The thermoluminescence was found when the pulverized powders from the whole seeds of six plant species or the hypocotyls from the seeds of five soybean varieties were irradiated at a liquid nitrogen temperature with gamma-rays. The spectra of luminescence emitted, the light peak temperature, the decaying after irradiation and the dose relationship of luminescence were determined. A high yield of the rapidly-decaying luminescence occurred in the more radiosensitive variety when irradiated with relatively lower doses. The very drastic decrease of the thermoluminescence was observed in the samples irradiated at room temperature prior to the exposure at 77 0 K. (auth.)

  1. Radiation dosimetry for microbial experiments in the International Space Station using different etched track and luminescent detectors

    Czech Academy of Sciences Publication Activity Database

    Goossens, O.; Vanhavere, F.; Leys, N.; De Boever, P.; O'Sullivan, D.; Zhou, D.; Spurný, František; Yukihara, E.; Gaza, R.; McKeever, S.

    2006-01-01

    Roč. 120, 1- 4 (2006), s. 433-437 ISSN 0144-8420 R&D Projects: GA MŠk 1P05OC032 Institutional research plan: CEZ:AV0Z10480505 Keywords : bacterial experiments * space flight * etched track detectors * thermoluminescent detectors Subject RIV: DN - Health Impact of the Environment Quality Impact factor: 0.446, year: 2006

  2. The thermoluminescence of carp otoliths: A fingerprint in ...

    African Journals Online (AJOL)

    use

    2011-12-14

    Dec 14, 2011 ... This paper reports a pilot study on the thermoluminescence (TL) of carbonate minerals of carp otoliths from the heavily polluted Baiyangdian Lake (BYD) in Hebei Province and non-polluted Miyun Water. Reservoir (MY) in Beijing Municipality of China. Analyses on trace elements of otoliths and water show.

  3. The thermoluminescence of carp otoliths: A fingerprint in ...

    African Journals Online (AJOL)

    This paper reports a pilot study on the thermoluminescence (TL) of carbonate minerals of carp otoliths from the heavily polluted Baiyangdian Lake (BYD) in Hebei Province and non-polluted Miyun Water Reservoir (MY) in Beijing Municipality of China. Analyses on trace elements of otoliths and water show that the heavy ...

  4. Neutron dosimetry using activation of thermoluminescent CaSO 4

    Science.gov (United States)

    Azorín, Juan; Gutiérrez, Alicia

    1984-11-01

    Sulfur activation in calcium sulfate doped with dysprosium (CaSO 4:Dy) thermoluminescent powder, which is bound in pure sulfur, has been used to measure the fast neutron dose at the tangential beam port of a Triga Mark III reactor. After a post-irradiation time of 3 d, the dosimeters were annealed at 600°C for 30 min in order to erase all the thermoluminescence acquired during the irradiation. The dosimeters were then stored to allow self-irradiation by betas from 32P produced by sulfur activation. The thermoluminescent signal accumulated during a post-irradiation time of 20 d due to a neutron fluence of 2.2 × 10 11 n/cm 2 was equivalent to an absorbed dose of 10 mGy of 60Co gamma rays. The thermoluminescence as a function of fast neutron dose fitted to a straight line on a log-log scale from 1 Gy to 10 4Gy.

  5. Spatially-resolved thermoluminescence from snail opercula using an EMCCD

    DEFF Research Database (Denmark)

    Duller, G.A.T.; Kook, Myung Ho; Stirling, R.J.

    2015-01-01

    In recent years opercula of the snail species Bithynia tentaculata have been shown to emit thermoluminescence (TL) signals that can be used to determine equivalent dose, and may be capable of dating events throughout the entire Quaternary period. Concentric growth lines are a notable feature of a...

  6. The thermoluminescent curve as parameter to compare archaeological ceramics

    International Nuclear Information System (INIS)

    Dominguez R, I.R.; Ramirez C, G.A.; Gonzalez M, P.R.; Mendoza A, D.; Martinez C, G.

    2006-01-01

    Most mineral materials, including the constituents of pottery, have the property of thermoluminescence (TL), where part of the energy from radioactive decay in the mineral is stored and later released as light upon strong heating. The intensity of emitted light as a function of temperature is the thermoluminescence glow curve. However, it is well-know the thermoluminescence glow curve form depends of several factors associates with the incident radiation and type of materials. Between the factors associated with the materials, it can be mentioned the quantity and type of crystalline phases, and quantity and type of impurities that they could be present in the material. That is to say, materials with different physicochemical characteristics will produce different thermoluminescence glow curve, although, they have been irradiated under the same conditions. In accordance with the above mentioned, it is possible to identified differences between pre hispanic ceramic belonging to a same site and other sites. In this work a discussion about advantages and disadvantages is presented. Some specific examples in ceramic artifacts belonging to the Matlatzinca and Teotihuacan cultures are included. (Author)

  7. Assessment of the suitability of zircons for thermoluminescence dating

    NARCIS (Netherlands)

    van Es, HJ; den Hartog, HW; de Meijer, RJ; Venema, LB; Donoghue, JF; Rozendaal, A

    2000-01-01

    A suit of zircon (ZrSiO4) samples has been selected for experiments by thermoluminescence (TL) and by Laser Ablation ICP-MS to study the role of rare earth elements (REE). It is shown that the trace element composition results for the heavy REE (HREE) are consistent, and that zircons are HREE

  8. Kerma determination in air on mamma by thermoluminescence

    International Nuclear Information System (INIS)

    Palacios P, L. L.; Rivera M, T.

    2009-10-01

    In this work the experimental results of the entrance exposition are shown and Kerma in air [mGy] in mamma obtained by irradiation of accreditation phantom of American College of Radiology (ACR). The irradiations were realized in a conventional mammography equipment of Hospital Juarez in Mexico; the technique used during the irradiations was of automatic exposition; the thickness for the phantom ACR obtained by the technique were of 4.2 and 4.5 cm; the kilo voltage pick was of 24 kV p , the time and the milli amperage per second variable. The measuring of Kerma in air was obtained with thermoluminescent dosemeters of solid state, of nano particles of zirconium dioxide prepared by the precipitation method. The dosemeters were homogenized previously in low energies of X-rays that are those used for mammography. The thermoluminescent dosemeters of ZrO 2 were calibrated by means of an ionization chamber for different expositions. The calibration curve is reported for the exposition and Kerma in air against thermoluminescent intensity obtained by reading of thermoluminescent dosemeters of ZrO 2 , as well as the technique employee for the Kerma determination in air and entrance exposition in mamma. (Author)

  9. Thermoluminescence in gamma irradiated iPP-VGVGCNF

    Energy Technology Data Exchange (ETDEWEB)

    Cherestes, Margareta [S. C. Dozimed SRL, Bucharest (Romania); Constantinescu, Livia Maria [University of Bucharest, Faculty of Physics, Magurele, Bucharest (Romania); Chipara, Dorina Magdalena, E-mail: dchipara@utpa.edu [The University of Texas Pan-American, Department of Physics and Geology, Edinburg, TX 78539 (United States); Cherestes, Codrut [S. C. Dozimed SRL, Bucharest (Romania); Chipara, Mircea [The University of Texas Pan-American, Department of Physics and Geology, Edinburg, TX 78539 (United States)

    2013-06-15

    Nanocomposites have been obtained by dispersing various amounts of vapor grown carbon nanofibers within isotactic polypropylene via melt mixing. The as obtained nanocomposites were gamma irradiated at various integral doses by using a {sup 60}Co source. The irradiation was performed in air, at room temperature, and at a dose rate of about 1 kGy/h up to an integral dose of 28 kGy. Thermoluminescence investigations revealed the role of carbon nanotubes in the radiation-induced modification of polymer-based nanocomposites. Almost all samples (pristine polymer and polymer-based nanocomposites irradiated and not irradiated) showed two overlapping thermoluminescence signals. It is concluded that the dispersion of carbon nanotubes decreases the amount of trapped electrons improving eventually the radiation stability of the polymeric matrix. The low temperature thermoluminescence peak was tentatively associated to melting phenomena. The origin of the high temperature thermoluminescence peak is more complex. Nevertheless, the experimental data suggests that this peak is sensitive to the polymer-filler interface.

  10. Deconvolution of the thermoluminescent emission curve. Second order kinetics

    International Nuclear Information System (INIS)

    Moreno y M, A.; Moreno B, A.

    1999-01-01

    In this work it is described the Randall and Wilkins second order kinetics in Microsoft Excel language, which allows its expression as the sum of Gaussian and the correction factors corresponding. These factors are obtained of the differences between the real thermoluminescent curve and the Gaussian proposed. The results obtained justify the Gaussian expression added to the correction factor. (Author)

  11. Thermoluminescence characteristics of Sm doped NaYF4 crystals

    Indian Academy of Sciences (India)

    2006-06-28

    Jun 28, 2006 ... investigation of spectroscopic properties of rare earth ions incorporated into different inorganic host matrices from the view point of searching for new materials with appli- cations in lasers, optical devices, solid state dosimeters, etc. Thermoluminescence (TL) studies help in understanding the emission of ...

  12. Development of a highly sensitive lithium fluoride thermoluminescence dosimeter

    International Nuclear Information System (INIS)

    Moraes da Silva, Teresinha de; Campos, Leticia Lucente

    1995-01-01

    In recent times, LiF: Mg, Cu, P thermoluminescent phosphor has been increasingly in use for radiation monitoring due its high sensitivity and ease of preparation. The Dosimetric Materials Production Laboratory of IPEN, (Nuclear Energy Institute) has developed a simple method to obtain high sensitivity LiF. The preparation method is described. (author). 4 refs., 1 fig., 1 tab

  13. The thermoluminescence of carp otoliths: A fingerprint in ...

    African Journals Online (AJOL)

    use

    2011-12-14

    Dec 14, 2011 ... that the heavy metal elements of BYD were much higher than those of MY, particularly on chromium ... These heavy metal elements could infiltrate ..... the thermoluminescence survey in prospecting for in-situ leachable sand stone type uranium deposit. Uranium Geol. 18: 118-121. Mao MZ, Liu ZH, Dong HR ...

  14. Investigations on thermoluminescent dosimetry (TLD) with doped alumina ceramics

    International Nuclear Information System (INIS)

    Janas, R.; Huebner, K.

    1976-01-01

    Alumina ceramics doped and burned under various conditions have been investigated with regard to their suitability for thermoluminescent dosimetry. The production of ceramics is described. The properties essential for dosimetric purposes, such as glow curve, energy dose characteristics, fading, recoverability, lower detection limit and energy dependence, are indicated. The advantages and disadvantages of alumina ceramics are compared. (author)

  15. Trace element geochemistry and thermoluminescence (TL) of quartz ...

    African Journals Online (AJOL)

    *

    Otolith is a typical biomineral carrier growing on insides of fish skull with prominent zoning structure formed by alternating layers of protein and calcium carbonate growing around the nucleus. Even though thermoluminescence (TL) analysis on biomineral has been widely used to measure the radiation exposure in the ...

  16. Application of numerical analysis methods to thermoluminescence dosimetry

    International Nuclear Information System (INIS)

    Gomez Ros, J. M.; Delgado, A.

    1989-01-01

    This report presents the application of numerical methods to thermoluminescence dosimetry (TLD), showing the advantages obtained over conventional evaluation systems. Different configurations of the analysis method are presented to operate in specific dosimetric applications of TLD, such as environmental monitoring and mailed dosimetry systems for quality assurance in radiotherapy facilities. (Author) 10 refs

  17. Calibration of Mg2SiO4(Tb) thermoluminescent dosimeters for use in determining diagnostic X-ray doses to Adult Health Study participants

    International Nuclear Information System (INIS)

    Kato, Kazuo; Antoku, Shigetoshi; Sawada, Shozo; Russell, W.J.

    1989-11-01

    Characteristics of Mg 2 SiO 4 (Tb) thermoluminescent dosimeters (TLD) were ascertained preparatory to measuring dose from diagnostic X-ray examinations received by Adult Health Study participants. These detectors are small, relatively sensitive to low-dose X rays, and are appropriate for precise dosimetry. Extensive calibration is necessary for precisely determining doses according to their thermoluminescent intensities. Their sensitivities were investigated, by dose according to X-ray tube voltage, and by exposure direction, to obtain directional dependence. Dosimeter sensitivity lessened due to the fading effect and diminution of the planchet. However, these adverse effects can be avoided by storing the dosimeters at least 1.5 hours and by using fresh silver-plated planchets. Thus, the TLDs, for which sensitivities were determined in this study, will be useful in subsequent diagnostic X-ray dosimetry. (author)

  18. Synthetic diamond devices for radiotherapy applications: Thermoluminescent dosimeter and ionisation chamber

    International Nuclear Information System (INIS)

    Descamps, C.; Tromson, D.; Mer, C.; Nesladek, M.; Bergonzo, P.

    2006-01-01

    In radiotherapy field, the major usage of dosimeters is in the measurement of the dose received by the patient during radiotherapy (in-vivo measurements) and in beam calibration and uniformity checks. Diamond exhibits several interesting characteristics that make it a good candidate for radiation detection. It is indeed soft-tissue equivalent (Z=6 compared to Z=7.42 for human tissue), mechanically robust and relatively insensitive to radiation damage, chemically stable and non toxic. Moreover, the recent availability of synthetic samples, grown under controlled conditions using the chemical vapour deposition (C.V.D.) technique, allowed decreasing the high cost and the long delivery time of diamond devices. Diamond can be use for off-line dosimetry as thermoluminescent dosimeters or for on-line dosimetry as ionisation chamber [2,3]. These both applications are reported here. For this study, samples were grown in the laboratory and devices were then tested under X-ray irradiations and in clinical environment under medical cobalt source. The work described in this paper was performed in the framework of the European Integrated Project M.A.E.S.T.R.O., Methods and Advanced Equipment for Simulation and Treatment in Radio-Oncology, (6. FP) which is granted by the European Commission.The first results of this study clearly show that C.V.D. diamond detectors are suitable for dosimetry in radiotherapy applications. Moreover, for both T.L. dosimeters and ionisation chambers applications, and even though the sensitivity is subsequently reduced, nitrogen incorporation in films seems to significantly improve the dosimetric characteristics of the devices. Therefore, the optimisation of the material quality appears as a very important issue in order to increase the dosimetric characteristics of devices and more particularly, for use as thermoluminescent dosimeters, other impurities (Nickel, Phosphorus) will be tested. For ionisation chamber applications, experiments with

  19. Detector to detector corrections: a comprehensive experimental study of detector specific correction factors for beam output measurements for small radiotherapy beams

    DEFF Research Database (Denmark)

    Azangwe, Godfrey; Grochowska, Paulina; Georg, Dietmar

    2014-01-01

    Purpose: The aim of the present study is to provide a comprehensive set of detector specific correction factors for beam output measurements for small beams, for a wide range of real time and passive detectors. The detector specific correction factors determined in this study may be potentially...... useful as a reference data set for small beam dosimetry measurements. Methods: Dose response of passive and real time detectors was investigated for small field sizes shaped with a micromultileaf collimator ranging from 0.6 × 0.6 cm2 to 4.2 × 4.2 cm2 and the measurements were extended to larger fields...... of up to 10 × 10 cm2. Measurements were performed at 5 cm depth, in a 6 MV photon beam. Detectors used included alanine, thermoluminescent dosimeters (TLDs), stereotactic diode, electron diode, photon diode, radiophotoluminescent dosimeters (RPLDs), radioluminescence detector based on carbon...

  20. Novel thermoluminescence foils for 2-D clinical dosimetry, based on CaSO{sub 4}:Dy

    Energy Technology Data Exchange (ETDEWEB)

    Klosowski, M., E-mail: mariusz.klosowski@ifj.edu.p [Institute of Nuclear Physics, Polish Academy of Sciences, ul. Radzikowskiego 152, 31-342 Krakow (Poland); Czopyk, L. [Institute of Nuclear Physics, Polish Academy of Sciences, ul. Radzikowskiego 152, 31-342 Krakow (Poland); Kisielewicz, K.; Kabat, D. [Centre of Oncology, Maria Sklodowska-Curie Memorial Institute, ul. Garncarska 11, 31-115 Krakow (Poland); Olko, P. [Institute of Nuclear Physics, Polish Academy of Sciences, ul. Radzikowskiego 152, 31-342 Krakow (Poland); Waligorski, M.P.R. [Centre of Oncology, Maria Sklodowska-Curie Memorial Institute, ul. Garncarska 11, 31-115 Krakow (Poland)

    2010-03-15

    The newly developed two-dimensional thermoluminescence (TL) foils made from CaSO{sub 4}:Dy TL powder and the high temperature polymer PFA, were tested for their dosimetric properties. The results were evaluated using laboratory TL reader with PCO CCD camera and round planchet heater, 72 mm in diameter. 55 x 55 x 0.3 mm{sup 3} foils were tested for dose response, reproducibility and spatial resolution. It was found that the detectors are linear up to at least 2 Gy and their spatial resolution is about 1 mm. A loss of sensitivity with repeated re-uses was observed (9% in 10 uses). It is attributable to the darkening of the detector due to oxidizing of impurities gathering at its surface and may be avoided by application of proper cleaning procedure. The foils were tested for measurements of 2-D dose distribution on 60 MeV proton beam at IFJ Krakow. The results show that 2-D TL foils based on CaSO{sub 4}:Dy can be a useful tool for quality assurance of proton beams.

  1. Do desenvolvimento global ao desenvolvimento local: novas perspectivas do desenvolvimento do turismo

    Directory of Open Access Journals (Sweden)

    Thiliane Meguis

    2015-07-01

    Full Text Available erifica-se que o debate em torno dos conceitos e modelos de desenvolvimento são cada vez mais frequentes atualmente já se percebe maior preocupação voltada principalmente para o bem estar social. Nesse sentido o Turismo de Base Comunitária (TBC será destacado como um paradigma para o desenvolvimento do turismo sustentável, que objetiva a participação social, ressaltando a sua escala “de baixo para cima”, onde a população local é o ator fundamental desse processo. Para maior compreensão deste assunto consideram-se as seguintes questões: o que é desenvolvimento afinal? Como alcança-lo? Para quê? Este trabalho buscará discutir sobre a importância das ações descentralizadoras de participação e democracia para o desenvolvimento do turismo. Acredita-se, que quando as pessoas criam o hábito de se relacionar por diversas razões sociais ela é capaz de promover um bem estar econômico, social e ambiental para os seus envolvidos, que vão além do mero crescimento econômico. Para isso, os assuntos abordados neste trabalho perpassam pela compreensão de desenvolvimento e crescimento econômico, tido por diversos pesquisadores como antônimos, até o entendimento do desenvolvimento local/endógeno. Após está análise teórica, verificar-se-á as suas relações com o desenvolvimento do turismo, em especial o turismo de base comunitária (TBC, bem como, a importância da formulação e implementação de políticas públicas que estejam de acordo com a realidade local. Utiliza-se como método a pesquisa qualitativa, de caráter descritivo para a compressão crítica dos textos, referente aos conceitos destacados.

  2. Thermoluminescent dosemeter in a X-ray diffractometer

    International Nuclear Information System (INIS)

    Mendoza A, D.; Gonzalez M, P.; Falcon B, T.; Castano, V.M.

    1999-01-01

    In this work it was presented the results obtained of the dosimetry which was realized in a X-ray diffractometer for powders, trademark Siemens D5000, using the thermoluminescent signal generated by the X-rays in the commercial dosemeter TLD-100 of Harshaw, US. In according to the results obtained, the radiation quantity received by an analysed material in the diffractometer, will be proportional to exposure time and it can vary from unities until tenths of grays. These results are very outstanding when are analysed crystalline materials in a diffractometer, for knowing the present crystalline phases, mainly if these are highly sensitive to the ionizing radiation, as it is the case of the thermoluminescent materials. (Author)

  3. Thermoluminescence of sulfated zircon exposed to gamma radiation

    International Nuclear Information System (INIS)

    Rubio, E.; Castano, V.M.; Mendoza A, E.; Gonzalez, P.R.

    2003-01-01

    In this work, the thermoluminescent (Tl) signal induced by gamma radiation in zirconia and sulfated zirconia samples embedded in Ptfe pellets is reported and discussed. In this case, samples were obtained through sol-gel method using zirconium n-propoxide and H 2 SO 4 as precursors, and later were subjected to thermal treatment at 600 C to obtain, the tetragonal phase accordingly to X-ray diffraction analysis. Experimental results show that the thermoluminescent glow peak depends on both, the crystalline structure and sulfate concentration. Two maximum peaks were observed located at 147 C and 274 C arising from the electronic transitions. Tl response as a function of the absorbed dose shows a linear increase for a wide of range exposure as well as good stability in time. The high sensitivity, dose linearity and signal stability of this material open the potential possibility to be used for the dosimetry applications. (Author)

  4. Thermoluminescence dating. Application to the chronology of volcanic ashes

    International Nuclear Information System (INIS)

    Pilleyre, T.

    1991-09-01

    Thermoluminescent (TL) dating is generally used for minerals heated in the past and can be used for absolute chronology of volcanic ashes but seems limited to less than 15.000 years. The aim of the thesis is the study of thermoluminescent properties of quartz for high doses and long irradiations using the red TL peak of quartz which is situated at high temperature (about 370 deg. C) to extend the method for higher ages. A theory, based on spatial correlation between electron and hole created during the same ionization, is developed. A chapter is devoted to dosimetry because of its importance in TL dating, especially alpha scintillation counting and the influence of humidity on the determination of annual dose. Volcanic samples are dated from 10.000 to 80.000 years before present

  5. Statistical methods to evaluate thermoluminescence ionizing radiation dosimetry data

    Energy Technology Data Exchange (ETDEWEB)

    Segre, Nadia; Matoso, Erika; Fagundes, Rosane Correa, E-mail: nadia.segre@ctmsp.mar.mil.b [Centro Tecnologico da Marinha em Sao Paulo (CEA/CTMSP), Ipero, SP (Brazil). Centro Experimental Aramar

    2011-07-01

    Ionizing radiation levels, evaluated through the exposure of CaF{sub 2}:Dy thermoluminescence dosimeters (TLD- 200), have been monitored at Centro Experimental Aramar (CEA), located at Ipero in Sao Paulo state, Brazil, since 1991 resulting in a large amount of measurements until 2009 (more than 2,000). The data amount associated with measurements dispersion, since every process has deviation, reinforces the utilization of statistical tools to evaluate the results, procedure also imposed by the Brazilian Standard CNEN-NN-3.01/PR- 3.01-008 which regulates the radiometric environmental monitoring. Thermoluminescence ionizing radiation dosimetry data are statistically compared in order to evaluate potential CEA's activities environmental impact. The statistical tools discussed in this work are box plots, control charts and analysis of variance. (author)

  6. Thermoluminescence authentication of T`ang and Han Dynasty pottery

    Energy Technology Data Exchange (ETDEWEB)

    Price, D.M. [Wollongong Univ., NSW (Australia). School of Geosciences

    1997-12-31

    More than 80 pieces of T`ang Dynasty and 40 Han Dynasty style ceramic wares have been analysed to determine the amount of thermoluminescence (TL) accumulated since the initial firing of the object and the level of the radiation flux which has created the TL. This paper presents a summary of the thermoluminescence analysis results. Approximately 60% of Han ceramics and 45% of the T`ang pottery authenticated have been shown to belong to periods other than that stylistically suggested. Items which have been found not to be of the anticipated antiquity generally fall into distinct age groups. Of the T`ang wares the most commonly copied item is found to be the horse and for the Han pieces, human figures and ewers/pots/vases represent the most frequently reproduced wares.

  7. Thermoluminescence authentication of T'ang and Han Dynasty pottery

    International Nuclear Information System (INIS)

    Price, D.M.

    1997-01-01

    More than 80 pieces of T'ang Dynasty and 40 Han Dynasty style ceramic wares have been analysed to determine the amount of thermoluminescence (TL) accumulated since the initial firing of the object and the level of the radiation flux which has created the TL. This paper presents a summary of the thermoluminescence analysis results. Approximately 60% of Han ceramics and 45% of the T'ang pottery authenticated have been shown to belong to periods other than that stylistically suggested. Items which have been found not to be of the anticipated antiquity generally fall into distinct age groups. Of the T'ang wares the most commonly copied item is found to be the horse and for the Han pieces, human figures and ewers/pots/vases represent the most frequently reproduced wares

  8. Thermoluminescent characteristics of inorganic dust from black pepper spice

    International Nuclear Information System (INIS)

    Furetta, C.; Cruz Z, E.; Favalli, A.

    2007-01-01

    Full text: The irradiation of spices is normally used for its sterilization, allowing this procedure to extend the storage time ir different needs, i.e. transportation over large distances from the production places to distribution points for commercialization. The irradiated food allows studying the behaviour and the characteristics of its inorganic content, i.e. minerals. The aim of this work is to study the main thermoluminescent (TL) characteristics of the inorganic dust extracted from Black pepper spice. TL responses as a function of the delivered gamma dose, fading at room temperature, effect of W irradiation are reported. The thermoluminescent kinetic parameters of the glow curves have been accurately analysed using the Computerized Glow Curve Deconvolution (CGCD) method and results are discussed. (Author)

  9. Preliminary research on thermoluminescence application in complicated geological situation

    International Nuclear Information System (INIS)

    Gong Gelian; Liu Chunsheng

    2003-01-01

    Thermoluminescent phenomenon resulting from two kinds of complicated geological situation, Ordos Basin and Huainan deposits in Anhui Province, is studied by the means of thermoluminescence counting method. It is shown that: (1) there are no apparent abnormalities of natural TL detected from the rock samples selected in the first 1000 meter depth of the Earth, and these natural TL are accumulated through natural radiation effects; (2) the natural TL shows statistically obvious reducing trends for the rock samples selected under the 2000 meter depth, and even no detectable TL is found for those rocks selected at 4000 meter depth. (3) the natural TL peaks corresponding to high temperature generally shift to the direction of higher temperature for the quartz-related rock samples, and several thermal events which occurred during the geological times might be responsible for this case

  10. Thermoluminescence sensitivity variations in LiF PTFE dosemeters incurred by improper handling procedures

    CERN Document Server

    Mason, E W; MacKinlay, Alistair F; Saunders, D

    1975-01-01

    A systematic study of some anomalous darkening effects and thermoluminescence sensitivity variations observed in LiF:PTFE thermoluminescent dosemeters is described. Various likely causes of such effects have been investigated. The manufacturer's recommended cleaning procedures have been found to be inadequate and, in some cases, have been found to actually promote discolouration of the dosemeters. Recommendations are given for the successful use of LiF:PTFE thermoluminescent dosemeters in personal dosimetry.

  11. Thermoluminescence of LiF: Mg, Ti between 77 and 315 K

    International Nuclear Information System (INIS)

    Rosa, L.A.R. da.

    1989-01-01

    A special thermoluminescent system was developed. It is able to operate right from liquid nitrogen temperature and also permits the determination of the sample thermoluminescent emission spectrum. Using this system, the thermoluminescence displayed by 77 K irradiated LiF:Mg,Ti (TLD-100), from the irradiation temperature to 315 K, was studied. In this temperature range seven glow peaks, at 139, 153, 194, 240, 260, 283 and 300 K, were determined. (author)

  12. Comparative study of thermoluminescent responses of diverse CVD diamonds

    Czech Academy of Sciences Publication Activity Database

    Krása, Josef; Marczewska, B.; Vorlíček, Vladimír; Olko, P.; Juha, Libor

    2007-01-01

    Roč. 16, - (2007), s. 1510-1516 ISSN 0925-9635 R&D Projects: GA MŠk 1P04LA235; GA MŠk LC510 Institutional research plan: CEZ:AV0Z10100520 Keywords : CVD diamond * thermoluminescence * read-out cycle * X-ray dosimetry Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.788, year: 2007

  13. Storage Telemetry of Radionuclide Tracers by Implantable Thermoluminescent Dosimeters

    DEFF Research Database (Denmark)

    Bojsen, J.; Møller, U.; Christensen, Poul

    1977-01-01

    A storage telemetrical method using thermoluminescent (TL) dosimeters for long-term measurements of incorporated radioactive substances in unrestrained rats has been developed. The system has been used in combination with radiotelemetrical registration of the circadian temperature rhythm. By sequ......, in subcutaneous tissues and tumor tissue. This TL method permits the repetition of an experiment on the same rat several times, and thereby avoids errors due to biological variations between animals....

  14. Food irradiation dosimetry using thermoluminescence of quartz sand

    International Nuclear Information System (INIS)

    Khan, H.M.; Ehlermann, D.A.E.

    1993-01-01

    Thermoluminescence of quartz sand, which is inert and concomitant to several food materials, has been investigated for applications in food irradiation dosimetry and detection of irradiated foods. The glow curves consist of at least three overlapping peaks from 100 to 420 C. The peak at lower temperature is not stable and decays quickly at room temperature. However, the peaks at higher temperature are stable and more useful for dosimetry work. The intensity of the peak at 360 C, measured using different optical filters, shows a linear response in the range of 0.05 to 23 kGy. Stability of these signals at different annealing temperatures has been investigated. Thermoluminescence from adhering minerals and contaminating dust in different food materials has been found useful for the detection of irradiation treatment. Since quartz is frequently one of these minerals, further computerized deconvolution of individual glow peaks from the complex glow curves of quartz sand was carried out which improves the dosimetric results. Possible applications of thermoluminescence of quartz sand in food irradiation dosimetry and detection of irradiated foods have been discussed. (orig.)

  15. A study of the high-temperature signal characteristics in the thermoluminescence of porcelain

    International Nuclear Information System (INIS)

    Yin Gongming

    2001-01-01

    The thermoluminescence pre-dose technique for dating ancient porcelain was developed in many laboratories. This technique was the only method which could directly determine the age of old porcelain. But the thermoluminescence high-temperature signal (over 200 degree C) had not been studied. The authors conduced a preliminary study of the characteristic of thermoluminescence high-temperature signal, such as the TL natural glow curve, and the glow curves after beta or alpha irradiation. Most of the 32 ancient porcelains had thermoluminescence high temperature signal, and only one peak in their TL glow curve was found

  16. Variation in thermoluminescence of irradiated brands of foodstuffs: a test for hygienic quality

    International Nuclear Information System (INIS)

    Mamoon, A.; Zaheer, A.; Abu-Abdullah, S.

    1996-01-01

    Thermoluminescence of irradiated foodstuffs such as herbs and spices, is mostly due to attached dust or soil particles. Different brands of the same foodstuff sometimes give thermoluminescent signals of different intensities, apparently due to different degrees of dust contamination. It is of obvious importance to choose brands of foodstuffs that appear to have less dust contamination, i.e. of better hygienic quality. Several food items were investigated with respect to their thermoluminescent (TL) emission in order to assess TL usefulness as an indicator of hygienic quality for foods prone to contamination by dust. In this regard some foodstuff were artificially contaminated with a soil sample and their thermoluminescent emission was obtained. (author)

  17. Assessment of CaSO4:Dy and LiF:Mg,Ti thermoluminescent dosimeters performance in the dosimetry of clinical electron beams

    International Nuclear Information System (INIS)

    Nunes, Maira Goes

    2008-01-01

    The assessment of the performance of CaS0 4 :Dy thermoluminescent detectors produced by IPEN in the dosimetry of clinical electron beams aims to propose an alternative to the LiF:Mg,Ti commercial dosimeters (TLD-100) largely applied in radiation therapy. The two types of thermoluminescent dosimeters were characterised with the use of PMMA, RMI-457 type solid water and water phantoms in radiation fields of 4, 6, 9, 12 and 16 MeV electrons of nominal energies in which the dose-response curves were obtained and the surface and depth doses were determined. The thermoluminescent response dependency with the electron nominal energies and the applied phantom were studied. The CaS0 4 :Dy presented the same behaviour than the LiF:Mg,Ti in such a way that its application as an alternative to the TLD-100 pellets in the radiation therapy dosimetry of electron beams is viable and presents the significantly higher sensitivity to the electron radiation as its main advantage. (author)

  18. Neutron Activation Foil and Thermoluminescent Dosimeter Responses to a Polyethylene Reflected Pulse of the CEA Valduc SILENE Critical Assembly

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Thomas Martin [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Celik, Cihangir [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); McMahan, Kimberly L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Lee, Yi-kang [French Atomic Energy Commission (CEA), Saclay (France); Gagnier, Emmanuel [French Atomic Energy Commission (CEA), Centre de Saclay, Gif sur Yvette; Authier, Nicolas [French Atomic Energy Commission (CEA), Salives (France). Valduc Centre for Nuclear Studies; Piot, Jerome [French Atomic Energy Commission (CEA), Salives (France). Valduc Centre for Nuclear Studies; Jacquet, Xavier [French Atomic Energy Commission (CEA), Salives (France). Valduc Centre for Nuclear Studies; Rousseau, Guillaume [French Atomic Energy Commission (CEA), Salives (France). Valduc Centre for Nuclear Studies; Reynolds, Kevin H. [Y-12 National Security Complex, Oak Ridge, TN (United States)

    2016-09-01

    This benchmark experiment was conducted as a joint venture between the US Department of Energy (DOE) and the French Commissariat à l'Energie Atomique (CEA). Staff at the Oak Ridge National Laboratory (ORNL) in the US and the Centre de Valduc in France planned this experiment. The experiment was conducted on October 19, 2010 in the SILENE critical assembly facility at Valduc. Several other organizations contributed to this experiment and the subsequent evaluation, including CEA Saclay, Lawrence Livermore National Laboratory (LLNL), the Y-12 National Security Complex (NSC), Babcock International Group in the United Kingdom, and Los Alamos National Laboratory (LANL). The goal of this experiment was to measure neutron activation and thermoluminescent dosimeter (TLD) doses from a source similar to a fissile solution critical excursion. The resulting benchmark can be used for validation of computer codes and nuclear data libraries as required when performing analysis of criticality accident alarm systems (CAASs). A secondary goal of this experiment was to qualitatively test performance of two CAAS detectors similar to those currently and formerly in use in some US DOE facilities. The detectors tested were the CIDAS MkX and the Rocky Flats NCD-91. The CIDAS detects gammas with a Geiger-Muller tube and the Rocky Flats detects neutrons via charged particles produced in a thin 6LiF disc depositing energy in a Si solid state detector. These detectors were being evaluated to determine whether they would alarm, so they were not expected to generate benchmark quality data.

  19. Comparing of the yield curve of the pediatric X-ray equipment using thermoluminescent dosimeters and cylindrical ionization chamber

    International Nuclear Information System (INIS)

    Filipov, Danielle; Schelin, Hugo R.; Tilly Junior, Joao G.

    2014-01-01

    The determination of the yield curve of a radiographic equipment should be realized once a year, or when the unit be serviced. Besides being a requirement of ANVISA, through this test is possible to determine the incident air kerma (at a given point in the center of the beam) - INAK. Based on these concepts, the main objective of this work is the comparison of yield curves of the pediatric X-ray apparatus using two different detectors: one cylindrical ionization chamber and thermoluminescent dosimeters type LiF: Mg, Cu, P, as per protocol RLA / 9/057 IAEA. Then the equation of the yield curve (generated by each detector) was used to determine the INAK of 10 pediatric examinations, performed on this equipment. After the process of calibration of both detectors, they were placed side by side at a focus of the tube equipment for determining the performance of the same curve. Finally, using the curves generated by two detectors, INAK values of the 10 tests were calculated (from the kVp values, and mAs focus-patient of each exams), generating difference values at most 5%. As a conclusion, it can be said that the TLD lithium fluoride doped with Mg, Cu and P and the cylindrical ionization chambers may be used satisfactorily to determine the yield curve, whether as quality control or dosimetry

  20. Comparison of simulated and experimental energy dependence curves of an individual thermoluminescent dosimeter

    International Nuclear Information System (INIS)

    Moraes, Cassiana V.; Nicolucci, Patricia; Pianoschi, Thatiane A.; Pela, Carlos A.

    2007-01-01

    Because of the difficulties in obtaining different radiation beams for experimental determination of energy dependence curves of thermoluminescent dosimeters, a Monte Carlo simulation code, which has been widely used in Radiation Dosimetry, was utilized to interpolate and extrapolate available experimental data. The Monte Carlo simulation code PENELOPE, was used in order to determine the energy dependence curves of the individual dosimeter used by the Center of Instrumentation, Dosimetry and Radioprotection of Sao Paulo University (CIDRA - USP) to inform the doses received by workers occupationally exposed to ionizing radiation. In the simulations using PENELOPE, a similar-to-real geometrical representation of the dosimeter was implemented, making it easier to study the effects of the incident beam and of the secondary radiation, produced in different filters, with the detectors and to determine the energy dependence curves of the dosimeter. Radiations beams of 15 to 250 KeV and a beam with 137 Cs energy (662 KeV) were used in the simulations. The energy dependence curves of the dosimeter were also obtained in experiments with some selected energies, according to the beam features established by ISO 4037-1. Both in the experimental approach and in the simulation the dosimeter was placed on the surface of an object resembling a human thorax. The simulated and experimental energy dependence curves in this study are in a better than 15% agreement for every energy used. The use of Monte Carlo simulation makes it possible not only to obtain the energy dependence curves of different sets of filter-detector for a wide range of energies but also facilitates the study of the optimization of filters and detectors used in the dosimeter with no extra costs. (author)

  1. Comparison of simulated and experimental energy dependence curves of an individual thermoluminescent dosimeter

    Energy Technology Data Exchange (ETDEWEB)

    Moraes, Cassiana V.; Nicolucci, Patricia; Pianoschi, Thatiane A.; Pela, Carlos A. [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Dept. de Fisica e Matematica. Centro de Instrumentacao, Dosimetria e Radioprotecao (CIDRA)

    2007-07-01

    Because of the difficulties in obtaining different radiation beams for experimental determination of energy dependence curves of thermoluminescent dosimeters, a Monte Carlo simulation code, which has been widely used in Radiation Dosimetry, was utilized to interpolate and extrapolate available experimental data. The Monte Carlo simulation code PENELOPE, was used in order to determine the energy dependence curves of the individual dosimeter used by the Center of Instrumentation, Dosimetry and Radioprotection of Sao Paulo University (CIDRA - USP) to inform the doses received by workers occupationally exposed to ionizing radiation. In the simulations using PENELOPE, a similar-to-real geometrical representation of the dosimeter was implemented, making it easier to study the effects of the incident beam and of the secondary radiation, produced in different filters, with the detectors and to determine the energy dependence curves of the dosimeter. Radiations beams of 15 to 250 KeV and a beam with {sup 137}Cs energy (662 KeV) were used in the simulations. The energy dependence curves of the dosimeter were also obtained in experiments with some selected energies, according to the beam features established by ISO 4037-1. Both in the experimental approach and in the simulation the dosimeter was placed on the surface of an object resembling a human thorax. The simulated and experimental energy dependence curves in this study are in a better than 15% agreement for every energy used. The use of Monte Carlo simulation makes it possible not only to obtain the energy dependence curves of different sets of filter-detector for a wide range of energies but also facilitates the study of the optimization of filters and detectors used in the dosimeter with no extra costs. (author)

  2. Energy and angular dependence of thermoluminescent materials to beta monitoring; Dependencia energetica e angular de materiais termoluminescentes para monitoracao beta

    Energy Technology Data Exchange (ETDEWEB)

    Cecatti, Sonia Garcia Pereira; Caldas, Linda V.E. [Instituto de Pesquisas Energeticas e Nucleares, Sao Paulo, SP (Brazil)]. E-mail: scecatti@fundacentro.gov.br

    2006-11-15

    Energy and angular dependences of different thermoluminescent materials were studied with the objective to verify which type of detector would be the most appropriate for beta monitoring of workers. Three types of CaSO{sub 4}:Dy + teflon pellets were studied. The energy dependence was evaluated using standard beta radiation sources ({sup 147} Pm, {sup 2}''0{sup 4} Tl and {sup 90} Sr+{sup 90} Y). For the angular dependence study, the pellets were exposed to beta radiation of the {sup 9}'0 Sr+{sup 90} Y source, varying the incidence angle between 0 deg C and 90 deg C. In relation to the studied characteristics, the CaSO{sub 4}:Dy + 10% C dosimeters were the most adequate for use in beta monitoring of workers. (author)

  3. Numerical analysis of thermoluminescence glow curves; Analisis numerico de las cruvas de termoluminiscencia

    Energy Technology Data Exchange (ETDEWEB)

    Gomez Ros, J. M.; Delgado, A.

    1989-07-01

    This report presents a method for the numerical analysis of complex thermoluminescence glow curves resolving the individual glow peak components. The method employs first order kinetics analytical expressions and is based In a Marquart-Levenberg minimization procedure. A simplified version of this method for thermoluminescence dosimetry (TLD) is also described and specifically developed to operate whit Lithium Fluoride TLD-100. (Author). 36 refs.

  4. Thermoluminescence, a method for determining the date at which a ceramic object was fired

    International Nuclear Information System (INIS)

    Sayre, E.V.

    The theory on which thermoluminescence dating of archeological ceramic objects is based and the measurement methods used are outlined. Separation of fine grain particles and quartz particles permits the determination of the thermoluminescence of each and often a more accurate age determination. The application of the method to the dating of a bronze horse from the Metropolitan Museum is described

  5. Thermoluminescence dosimetry and its applications in medicine. Part 2: history and applications

    International Nuclear Information System (INIS)

    Kron, T.

    1995-01-01

    Thermoluminescence dosimetry (TLD) has been available for dosimetry of ionising radiation for nearly 100 years. The variety of materials and their different physical forms allow the determination of different radiation qualities over a wide range of absorbed dose. This makes TL dosimeters useful in radiation protection where dose levels of μ Gy are monitored as well as in radiotherapy where doses up to several Gray are to be measured. The major advantages of TL detectors are their small physical size and that no cables or auxiliary equipment is required during the dose assessment. TLD is considered to be a good method for point dose measurements in phantoms as well as for in vivo dosimetry on patients during radiotherapy treatment. As an integrative dosimetric technique, it can be applied to personal dosimetry and it lends itself to the determination of dose distributions due to multiple or moving radiation sources (e.g. conformal and dynamic radiotherapy, computed tomography). In addition, TL dosimeters are easy to transport, and they can be mailed. This makes them well suited for intercomparison of doses delivered in different institutions. The present article aims at describing the various applications TLD has found in medicine by taking into consideration the physics and practice of TLD measurements which have been discussed in the first part of this review. 198 refs., 4 tabs., 2 figs

  6. Theoretical Studies on the Physical and Environmental Factors Which Govern the Thermal Fading of Thermoluminescence Signal

    International Nuclear Information System (INIS)

    Rasheedy, M.S.; El-Sherif, M.A.; Hefni, M.A.

    2008-01-01

    Thermoluminescence solid-state detector is widely used to determine the dose in personnel and environmental monitoring for radiation protection purposes, for instance in the field of nuclear power production, medicine and research. However, thermal fading is a limiting factor for a long-term application, especially where temperature is changing significantly during the accumulation period. This paper studied the influence of temperature and duration of storage after irradiation on the thermal fading of the TL signal. Also, this paper discussed the dependence of the thermal fading on the trap parameters of TL glow peak. The most important parameters, which were considered here include the order of kinetics b, the depth of the trap level E (eV) and the frequency factor S (s-1). The dependence of the thermal fading on thermal stability parameters, namely trap depths and frequency factors for the glow peaks is discussed. The variation of the thermal fading as a function of the order of kinetics is demonstrated. In addition, this paper discussed the dependence of the thermal fading on the absorbed dose in case of first-, second- and general-order kinetics. The above-mentioned studies were arranged considering the models of first-, second- and general-order of kinetics

  7. Evaluation of thermoluminescent dosimeters using water equivalent phantoms for application in clinical electrons beams dosimetry

    International Nuclear Information System (INIS)

    Bravim, Amanda

    2010-01-01

    The dosimetry in Radiotherapy provides the calibration of the radiation beam as well as the quality control of the dose in the clinical routine. Its main objective is to determine with greater accuracy the dose absorbed by the tumor. This study aimed to evaluate the behavior of three thermoluminescent dosimeters for the clinical electron beam dosimetry. The performance of the calcium sulfate detector doped with dysprosium (CaSO 4 : Dy) produced by IPEN was compared with two dosimeters commercially available by Harshaw. Both are named TLD-100, however they differ in their dimensions. The dosimeters were evaluated using water, solid water (RMI-457) and PMMA phantoms in different exposure fields for 4, 6, 9, 12 and 16 MeV electron beam energies. It was also performed measurements in photon beams of 6 and 15 MV (2 and 5 MeV) only for comparison. The dose-response curves were obtained for the 60 Co gamma radiation in air and under conditions of electronic equilibrium, both for clinical beam of photons and electrons in maximum dose depths. The sensitivity, reproducibility, intrinsic efficiency and energy dependence response of dosimeters were studied. The CaSO 4 : Dy showed the same behavior of TLD-100, demonstrating only an advantage in the sensitivity to the beams and radiation doses studied. Thus, the dosimeter produced by IPEN can be considered a new alternative for dosimetry in Radiotherapy departments. (author)

  8. The thermoluminescence glow-curve analysis using GlowFit - the new powerful tool for deconvolution

    International Nuclear Information System (INIS)

    Puchalska, M.; Bilski, P.

    2005-10-01

    A new computer program, GlowFit, for deconvoluting first-order kinetics thermoluminescence (TL) glow-curves has been developed. A non-linear function describing a single glow-peak is fitted to experimental points using the least squares Levenberg-Marquardt method. The main advantage of GlowFit is in its ability to resolve complex TL glow-curves consisting of strongly overlapping peaks, such as those observed in heavily doped LiF:Mg,Ti (MTT) detectors. This resolution is achieved mainly by setting constraints or by fixing selected parameters. The initial values of the fitted parameters are placed in the so-called pattern files. GlowFit is a Microsoft Windows-operated user-friendly program. Its graphic interface enables easy intuitive manipulation of glow-peaks, at the initial stage (parameter initialization) and at the final stage (manual adjustment) of fitting peak parameters to the glow-curves. The program is freely downloadable from the web site www.ifj.edu.pl/NPP/deconvolution.htm (author)

  9. O paradigma do desenvolvimento: do mito fundador ao novo desenvolvimento

    Directory of Open Access Journals (Sweden)

    Anete B.L. Ivo

    Full Text Available Este artigo busca historicizar contextos que reorientaram a noção de desenvolvimento, no Brasil, desde os anos 30-80, passando pelo ajuste neoliberal dos anos 90, até inflexões atuais que indagam se o novo intervencionismo massivo e estratégico do Estado em políticas sociais para os mais pobres aponta para um novo modelo de desenvolvimento. A análise apresenta inflexões do modelo cepalino de 50-60 e tenta priorizar dimensões sociais na mediação das contradições entre a economia, a política e o institucional. O fio condutor toma dois vetores analíticos: o tema do conflito (redistributivo e o da integração. O primeiro é assentado nas coalizões das classes e confronto entre atores nacionais e agências multilaterais; e o da integração, na contraface do conflito, considera a abertura das políticas públicas e, também, a inovação de atores sociais e políticos em novos arranjos voltados para os objetivos do bem-estar social e da cidadania, de uma perspectiva mais sustentada.

  10. Thermoluminescence curves simulation using genetic algorithm with factorial design

    Science.gov (United States)

    Popko, E. A.; Weinstein, I. A.

    2016-05-01

    The evolutionary approach is an effective optimization tool for numeric analysis of thermoluminescence (TL) processes to assess the microparameters of kinetic models and to determine its effects on the shape of TL peaks. In this paper, the procedure for tuning of genetic algorithm (GA) is presented. This approach is based on multifactorial experiment and allows choosing intrinsic mechanisms of evolutionary operators which provide the most efficient algorithm performance. The proposed method is tested by considering the “one trap-one recombination center” (OTOR) model as an example and advantages for approximation of experimental TL curves are shown.

  11. Exoemission and thermoluminescence from human enamel and shark enameloid

    International Nuclear Information System (INIS)

    Davies, J.E.

    1983-01-01

    Simultaneous measurements of exoelectron emission and thermoluminescence from powdered biological apatites, which have not been chemically or thermally pretreated, are reported. Recycling, that is, consecutive irradiation and non-isothermal scanning, is shown to change both the form of the glow curves and emissivity of samples. Two biological apatites of the hydroxyapatite type (human enamel) and fluorapatite type (shark enameloid) are compared. Although their initial glow curves are different, recycling renders the glow curves similar suggesting that the defects involved are a product of the host lattice. The relevance of exoemission as a ''fingerprinting'' technique for biologically reactive material is discussed. (author)

  12. Thermoluminescent determination of prehistoric heat treatment of chert artifacts

    International Nuclear Information System (INIS)

    Melcher, C.L.; Zimmerman, D.W.

    1977-01-01

    In recent years archeologists have become interested in the extent to which prehistoric peoples heat-treated chert prior to shaping it into tools. Thermoluminescent determination of the radiation dose accumulated by an artifact since it was formed or last heated provides a simple, reliable test for such heat treatment. This test can be applied to single artifacts without the need for raw source material for comparison. Results on 25 artifacts from four sites indicate that, for many chert sources, color and luster are not useful indicators of heat treatment by prehistoric peoples

  13. Personnel radiation monitoring by thermoluminescence dosimetry (1995-96)

    International Nuclear Information System (INIS)

    Daw Mi Cho Cho; Daw Yi Yi Khin; Daw San San; U Maung Maung Tin; Daw Hla Hla Win

    2001-01-01

    Personnel radiation monitoring which is the dose assessment of individual doses from external radiation received by radiation workers has been carried out by Thermoluminescence Dosimetry system consisting of a Vinten Toledo TLD reader, LiF dosimeters and associated equipment. The exposed TLD dosimeters were measured by TLD reader and the dose evaluation and dose registration were done on personal computer. Due to the records of 1995-96, most of the radiation workers complied with the permissible dose recommended by IAEA and ICRP 60. (author)

  14. Thermoluminescence of the Z centre in Mg-doped KCl

    International Nuclear Information System (INIS)

    Kamavisdar, V.S.; Deshmukh, B.T.

    1980-01-01

    Optical absorption and thermoluminescence measurements on KCl:Mg 2+ are reported. Bleaching in F band introduces a new glow peak at 406 K in the glow curves. A similar peak is observed in microcrystalline powders. When this peak is thermally cleaned, the broadening of the absorption observed in prolonged F bleached crystals is removed. On the basis of these observations, the glow peak at 406 K is tentatively attributed to Z 1 centres. The glow peak at 394 K observed in microcrystalline powders is attributed to a combined effect of deformation and Z 1 centres. (author)

  15. Method of making isodose curve using thermoluminescence dosemeter

    International Nuclear Information System (INIS)

    Bakar Ramain, A.

    1975-01-01

    Line source of 60 Co in the form of needles and tubes are extensively used in radiotherapy in moulds, implants, and intracavitary techniques for the treatment of malignant lesions. It is important to have isodose distributions in tissue for those source for purposes of treatment planning. The isodose distributions have been obtained experimentally by using tinny lithium-fluoride (Lsub(i)F) thermoluminescent dosemeters (TLD) and they are compared to the theoretical results. The distinct advantages of Lsub(i)F (TLD) in such measurements are briefly discussed. (author)

  16. Thermoluminescent characteristics of ZrO2:Nd films

    International Nuclear Information System (INIS)

    Vera B, G.; Rivera M, T.; Azorin N, J.; Falcony G, C.; Garcia H, M.; Martinez S, E.

    2002-01-01

    In this work it is exposed the obtained results after analysing the photo luminescent and thermoluminescent characteristics of activated zirconium oxide with neodymium (ZrO 2 :Nd) and its possible application in the UV radiation dosimetry. The realized experiments had as objective to study the characteristics such as the optimum thermal erased treatment, the influence of light on the response, the response depending on the wavelength, the fadeout of the information, the temperature effect, the response depending on the time and the recurring of the response. The results show that the ZrO 2 :Nd is a promising material to be used as Tl dosemeter for the UV radiation. (Author)

  17. Use of thermoluminescent dosimetry in gamma radiation fields studies

    International Nuclear Information System (INIS)

    Carron, W.

    1987-01-01

    The depth-dose curves for gamma rays in material of interest to agronomy were obtained using lithium fluoride thermoluminescent dosimeters. The dose conversion factors for LiF were determined from curves of the absorved dose versus depth in water, wood and soil. Mathematics equations were chosen to best fit these curves. In the view of the results we came to the conclusion that in the studied materials the absorved radiation dose presents a great variation to the depth and could be correlated through of the exponential regression. (author)

  18. On the second kinetic order thermoluminescent glow curves

    International Nuclear Information System (INIS)

    Dang Thanh Luong; Nguyen Hao Quang; Hoang Minh Giang

    1995-01-01

    The kinetic parameters of thermoluminescent material such as CaF 2 -N and CaSO 4 -Dy with the different grain sizes are investigated in detail using the least square method of fitting. It was found that the activation energy E (or trap depth) and peak temperature T m ax are changed with the elapsed time between the irradiation and read-out for the low temperature glow curve peaks. The similar TL glow curve shapes are obtained for the different CaSO 4 -Dy grain size. (author). 7 refs., 5 figs., 2 tabs

  19. The contribution of Teflon to the thermoluminescent signal

    International Nuclear Information System (INIS)

    German, U.; Weinstein, M.; Ben-Shachar; Pelled, O.

    1997-01-01

    In the thermoluminescent method, we are measuring the light emitted by the phosphor (called TL output), irradiated previously by ionizing radiation. There are several other effects, which can cause emission of light similar to the TL output, which can affect the results of personnel and environmental dosimetry, especially for low doses. It is described several such effects, as illumination of lithium fluoride thermoluminescent dosimeters, particularly with ultraviolet wavelengths. It was presented that the results of the glow curve of LiF:Mg,Ti chips, after exposure to different non-ionizing radiation (u.v., microwave, electric sparks). It has reviewed the reports of light induced signals in LiF ( I > 380 nm). These effects cause dosimeters to emit TL similar to that caused by exposure to ionizing These effects cause dosimeters to emit TL similar to that caused by exposure to ionizing radiation.A signal is received when heating teflon sheets, which contributes to the TL signal. It was pointed out that the light induced TL emission from the teflon has a glow peak 120 degree C. The purpose of the present work was to perform a quantitative evaluation of the glow contributed by the teflon used in the TLD cards employed by us Harshaw - TLD 100 for different storage conditions. (authors)

  20. Thermoluminescent properties of CVD diamond: applications to ionising radiation dosimetry

    International Nuclear Information System (INIS)

    Petitfils, A.

    2007-09-01

    Remarkable properties of synthetic diamond (human soft tissue equivalence, chemical stability, non-toxicity) make this material suitable for medical application as thermoluminescent dosimeter (TLD). This work highlights the interest of this material as radiotherapy TLD. In the first stage of this work, we looked after thermoluminescent (TL) and dosimetric properties of polycrystalline diamond made by Chemically Vapor Deposited (CVD) synthesis. Dosimetric characteristics are satisfactory as TLD for medical application. Luminescence thermal quenching on diamond has been investigated. This phenomenon leads to a decrease of dosimetric TL peak sensitivity when the heating rate increases. The second part of this work analyses the use of synthetic diamond as TLD in radiotherapy. Dose profiles, depth dose distributions and the cartography of an electron beam obtained with our samples are in very good agreement with results from an ionisation chamber. It is clearly shown that CVD) diamond is of interest to check beams of treatment accelerators. The use of these samples in a control of treatment with Intensity Modulated Radiation Therapy underlines good response of synthetic diamond in high dose gradient areas. These results indicate that CVD diamond is a promising material for radiotherapy dosimetry. (author)

  1. Effect of Mineral Composition on Thermoluminescence Analysis of Irradiated Garlics

    International Nuclear Information System (INIS)

    Sookkasem, Atitaya; Wanwisa, Sudprasert; Vitittheeranon, Arag

    2009-07-01

    Full text: Thermoluminescence (TL) is one of the most popular techniques used for identification of irradiated foods such as spices, herbs and dried fruits in accordance with the Codex Standards. TL analysis is based on the determination of TL of adhering or contaminating minerals in foods. This research aimed to study the effect of mineral composition on the TL intensity. The composited minerals were extracted from 3 types of non-irradiated and irradiated garlic powders by sodium polytungstate solution. X-ray diffraction (XRD) spectroscopy was employed to investigate the type and amount of minerals present in garlic powders. TL of separated minerals were analysed using a Harshaw 4500 TL reader. The results showed that the mineral composition of garlic powders was mainly quartz of varying amounts depending on types of garlics. The TL intensity linearly increased with the amount of quartz present in the samples. It can be concluded that the amount of minerals affect the TL intensity which might influence the identification of irradiated tretment of garlics by thermoluminescence

  2. A preliminary approach to identify irradiated foods by thermoluminescence measurements

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Choonshik, E-mail: maggic7@korea.kr [Gyeong-In Regional Korea Food and Drug Administration, Juan-Dong 120, Nam-Gu, Incheon 402-835 (Korea, Republic of); Department of Bioscience and Biotechnology, Konkuk University, Hwayang-Dong 1, Gwangjin-Gu, Seoul 143-701 (Korea, Republic of); Kim, Hyoung-Ook [Gyeong-In Regional Korea Food and Drug Administration, Juan-Dong 120, Nam-Gu, Incheon 402-835 (Korea, Republic of); Lim, Yoongho [Department of Bioscience and Biotechnology, Konkuk University, Hwayang-Dong 1, Gwangjin-Gu, Seoul 143-701 (Korea, Republic of)

    2012-07-15

    Thermoluminescence (TL) is one of the physical methods for the identification of irradiated foods. Among the currently developed methods, TL is the most widely used method for the identification of irradiated foods. However, in order to use this method, silicate minerals should be isolated from food samples. The process for the isolation of silicate minerals is time consuming and laborious. In this work, we have investigated the applicability of the TL method using iron-containing minerals instead of silicate minerals. In the TL analyses of dried spices, TL glow curves of iron-containing minerals showed maximum temperatures between 150 and 250 Degree-Sign C which were the same as those of silicate minerals. The process for the mineral separation of the proposed method is simple, fast, easy, and reliable. Moreover, the analysis results including TL ratio have not shown significant differences compared with the silicate minerals method. As a result, the TL measurements using the iron-containing minerals could be an excellent method for the identification of the irradiated foods, including dried spices. - Highlights: Black-Right-Pointing-Pointer A thermoluminescence method using iron-containing minerals is proposed. Black-Right-Pointing-Pointer Current method using silicate minerals is time consuming and laborious. Black-Right-Pointing-Pointer However, the proposed method is simple, fast, easy, and reliable. Black-Right-Pointing-Pointer Analysis results are similar to those of the silicate minerals method.

  3. Thermoluminescence response of rare earth activated zinc lithium borate glass

    Science.gov (United States)

    Saidu, A.; Wagiran, H.; Saeed, M. A.; Obayes, H. K.; Bala, A.; Usman, F.

    2018-03-01

    New glasses of zinc lithium borate doped with terbium oxide were synthesized by high temperature solid-state reaction. The amorphous nature of the glasses was confirmed using x-ray diffraction analysis (XRD). Thermoluminescence (TL) response of pure zinc lithium borate (ZLB) and zinc lithium borate doped with terbium (ZLB: Tb) exposed to gamma radiation was measured and compared. There is significant enhancement in the TL yields of ZLB: Tb compared to that of pure ZLB. Effect of varying concentration of dopant (Tb4O7) on the TL response of zinc lithium borate was investigated. 0.3 mol% concentration of Tb exhibited strongest TL intensity. Thermoluminescence curve of the phosphor consist of single isolated peak. The TL response of the new materials to the exposed radiation is linear within 0.5-100 Gy range of dose with sublinearity at the lower region of the curve. High sensitivity was exhibited by the new amorphous materials. Reproducibility, thermal fading and energy response of the proposed TLD were investigated and shows remarkable result that made the phosphor suitable for radiation dosimetry.

  4. Thermoluminescence properties of zinc oxide obtained by solution combustion synthesis

    Energy Technology Data Exchange (ETDEWEB)

    Orante B, V. R.; Escobar O, F. M.; Cruz V, C. [Universidad de Sonora, Departamento de Investigacion en Polimeros y Materiales, Apdo. Postal 130, 83000 Hermosillo, Sonora (Mexico); Bernal, R., E-mail: victor.orante@polimeros.uson.mx [Universidad de Sonora, Departamento de Investigacion en Fisica, Apdo. Postal 5-088, 83190 Hermosillo, Sonora (Mexico)

    2014-08-15

    High-dose thermoluminescence dosimetry properties of novel zinc oxide obtained by solution combustion synthesis in a glycine-nitrate process, with a non-stoichiometric value of the elemental stoichiometric coefficient (Φ{sub c}) are presented in this work. Zn O powder samples obtained were annealed afterwards at 900 grades C during 2 h in air. Sintered particles of sizes between ∼ 0.5 and ∼ 2 μm were obtained, according to scanning electron microscopy results. X-ray diffraction indicates the presence of the hexagonal phase of Zn O for the powder samples obtained, before and after thermal annealing, without any remaining nitrate peaks observed. Thermoluminescence glow curves of Zn O obtained after being exposed to beta radiation consists of two maxima; one located at ∼ 149 grades C and another at ∼ 308 grades C, being the latter the dosimetric component of the curve. Dosimetric characterization of non-stoichiometric zinc oxide provided experimental evidence like asymptotic behavior of the Tl signal fading for times greater than 16 h between irradiation and the corresponding Tl readout, as well as the linear behaviour of the dose response without saturation in the dose interval studied (from 12.5 up to 400 Gy). Such characteristics place Zn O phosphors obtained in this work as a promising material for high-dose radiation dosimetry applications (e.g., radiotherapy and food industry). (author)

  5. Thermoluminescence properties of zinc oxide obtained by solution combustion synthesis

    International Nuclear Information System (INIS)

    Orante B, V. R.; Escobar O, F. M.; Cruz V, C.; Bernal, R.

    2014-08-01

    High-dose thermoluminescence dosimetry properties of novel zinc oxide obtained by solution combustion synthesis in a glycine-nitrate process, with a non-stoichiometric value of the elemental stoichiometric coefficient (Φ c ) are presented in this work. Zn O powder samples obtained were annealed afterwards at 900 grades C during 2 h in air. Sintered particles of sizes between ∼ 0.5 and ∼ 2 μm were obtained, according to scanning electron microscopy results. X-ray diffraction indicates the presence of the hexagonal phase of Zn O for the powder samples obtained, before and after thermal annealing, without any remaining nitrate peaks observed. Thermoluminescence glow curves of Zn O obtained after being exposed to beta radiation consists of two maxima; one located at ∼ 149 grades C and another at ∼ 308 grades C, being the latter the dosimetric component of the curve. Dosimetric characterization of non-stoichiometric zinc oxide provided experimental evidence like asymptotic behavior of the Tl signal fading for times greater than 16 h between irradiation and the corresponding Tl readout, as well as the linear behaviour of the dose response without saturation in the dose interval studied (from 12.5 up to 400 Gy). Such characteristics place Zn O phosphors obtained in this work as a promising material for high-dose radiation dosimetry applications (e.g., radiotherapy and food industry). (author)

  6. Effect of thermal decomposition of hydroxyapatite on the thermoluminescent response

    Energy Technology Data Exchange (ETDEWEB)

    Sandoval C, K. J.; Zarate M, J.; Lemus R, J. [Universidad Michoacana de San Nicolas de Hidalgo, Instituto de Investigaciones Metalurgicas, Ciudad Universitaria, Edificio U, 58060 Morelia, Michoacan (Mexico); Rivera M, T., E-mail: karlasandovalc@gmail.com [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Av. Legaria 694, Col. Irrigacion, 11500 Mexico D. F. (Mexico)

    2014-08-15

    In this work, a study on the thermoluminescence (Tl) induced by gamma radiation in synthetic hydroxyapatite (Hap) annealed at different temperatures obtained by the precipitation method is presented. Synthesis of hydroxyapatite Hap was carried out starting from inorganic precursors [Ca(NO{sub 3}){sub 2}·4H{sub 2}O and (NH{sub 4}){sub 2}HPO{sub 4}]. The precipitate was filtered, washed, dried and then the powder was calcined at different temperatures until the Hap decomposition. The structural and morphological characterization was carried out using both X-ray diffraction (XRD) and scanning electron microscopy (Sem) techniques. Thermoluminescent (Tl) properties of Hap powders were irradiated at different gamma radiation doses. According to X ray diffraction patterns, the tricalcium diphosphate phase (Tcp) appear when the Hap was calcined at 900 grades C. Tl glow curve showed two peaks located at around 200 and 300 grades C, respectively. Tl response as a function of gamma radiation dose was in a wide range from 25 to 100 Gy. The fading of the Tl response at 134 days after irradiation was measured. Experimental results showed that the synthetic hydroxyapatite obtained by precipitation technique may have dosimetric applications when is annealed at temperature of 900 grades C, where the Tcp phase appears and contributes to Tl response, which opens the possibility of using this biomaterials in the area of dosimetry, as they are generally used for biomedical implants. (author)

  7. Thermoluminescent of induced calcite by gamma and ultraviolet radiation

    International Nuclear Information System (INIS)

    Lima, J.F. de.

    1987-01-01

    Samples of brazilian calcite, exposed to gamma radiation in laboratory and heated at constant rate of 2.7 0 C/s, showed three glow peaks at 150, 250 and 350 0 C in their thermoluminescent emission curves. The analysis of these peaks, using different models, indicated that they follow a second order kinetics; it has been obtained, for the activation energy, 1.3, 1.5 and 1.7 eV, and, for the pre-exponential factors, 8.1 x 10 14 , 6.8 x10 13 and 2.4 x 10 12 s -1 . Although the total thermoluminescent emission has stayed constant, the relative height of glow peaks has changed with the temperature of annealing in the range of 400 to 700 0 C. Exposed samples were also illuminated with ultraviolet light and the resultant curves showed partial or total bleaching or some glow peaks and the growth of peaks at lower temperatures. Samples of virgin calcite, submited to increasing exposures of gamma rays, showed a corresponding enhancement of the optical absorption bands in the range of 25000 to 47000 cm -1 A subsequent illumination of these samples with ultraviolet light produced a decrease of the optical absorption bands at the same range. (author) [pt

  8. A theoretical description of complex thermoluminescence curves: 2

    International Nuclear Information System (INIS)

    Kantorovich, L.N.; Fogel, G.M.

    1989-01-01

    Thermoluminescence kinetics is discussed using a model with one type of recombination centre and an arbitrary number of trapping centre types, assuming that electron retrapping is dominant. A distinctive feature of the suggested method is that an integral equation is obtained for the one-time function z(t) through which both the intensity of the thermoluminescence curve (TLC) and the concentration of charge carriers are expressed. Using a series of approximations, which are analysed in detail, analytical solutions of the integral equation are obtained for an arbitrary elementary peak in a complex TLC consisting of a number of slightly overlapping peaks. The comparison of the theoretical results with the numerical ones obtained by the Runge-Kutta method shows that the obtained analytical expression is precise for the first peak and describes the following TLC peaks satisfactorily. The possibility of using the results of the present study for computer division of a complex TLC into elementary components, even in the case of considerably overlapping peaks, is also discussed. (author)

  9. A preliminary approach to identify irradiated foods by thermoluminescence measurements

    International Nuclear Information System (INIS)

    Shin, Choonshik; Kim, Hyoung-Ook; Lim, Yoongho

    2012-01-01

    Thermoluminescence (TL) is one of the physical methods for the identification of irradiated foods. Among the currently developed methods, TL is the most widely used method for the identification of irradiated foods. However, in order to use this method, silicate minerals should be isolated from food samples. The process for the isolation of silicate minerals is time consuming and laborious. In this work, we have investigated the applicability of the TL method using iron-containing minerals instead of silicate minerals. In the TL analyses of dried spices, TL glow curves of iron-containing minerals showed maximum temperatures between 150 and 250 °C which were the same as those of silicate minerals. The process for the mineral separation of the proposed method is simple, fast, easy, and reliable. Moreover, the analysis results including TL ratio have not shown significant differences compared with the silicate minerals method. As a result, the TL measurements using the iron-containing minerals could be an excellent method for the identification of the irradiated foods, including dried spices. - Highlights: ► A thermoluminescence method using iron-containing minerals is proposed. ► Current method using silicate minerals is time consuming and laborious. ► However, the proposed method is simple, fast, easy, and reliable. ► Analysis results are similar to those of the silicate minerals method.

  10. Thermoluminescence of double fluorides doped with rare earths

    International Nuclear Information System (INIS)

    Azorin N, J.; Sanchez R, A.; Khaidukov, N.M.

    2004-01-01

    In this work the thermoluminescent characteristics of double fluorides K 2 YF 5 , K 2 GdF 5 and K 2 LuF 5 doped are presented with Tb 3+ , studied in the interval of temperature from 30 to 400 C. The materials that presented better answer to the irradiation with particles beta and with ultraviolet light they were the K 2 YF 5 : Tb (1% at. Tb 3+ ) and the K 2 LuF 5 : Tb (1% at. Tb 3+ ); while the K 2 YF 5 : Tb to high concentrations (10% and 20% at. Tb 3+ ) and the K 2 LuF 5 : Tb (1% at. Tb 3+ ) and the K 2 LuF 5 : Tb (1% at. Tb 3+ ) they presented an acceptable answer in front of the gamma radiation. The intensity of the Tl answer induced in these materials is a decisive factor to continue studying its dosimetric characteristics, what allows to consider them as the base for the development of potential materials to use them in the dosimetry of beta particles, of the UV light of the gamma radiation using the thermoluminescence method. (Author)

  11. Detector trends

    International Nuclear Information System (INIS)

    Charpak, G.

    1986-01-01

    The author describes briefly the development of detectors for high energy physics experiments. Especially considered are semiconductor microstrip detectors, drift tubes, holographic bubble chambers, scintillating fiber optics, and calorimeters. (HSI).

  12. Detector Unit

    CERN Multimedia

    1960-01-01

    Original detector unit of the Instituut voor Kernfysisch Onderzoek (IKO) BOL project. This detector unit shows that silicon detectors for nuclear physics particle detection were already developed and in use in the 1960's in Amsterdam. Also the idea of putting 'strips' onto the silicon for high spatial resolution of a particle's impact on the detector were implemented in the BOL project which used 64 of these detector units. The IKO BOL project with its silicon particle detectors was designed, built and operated from 1965 to roughly 1977. Detector Unit of the BOL project: These detectors, notably the ‘checkerboard detector’, were developed during the years 1964-1968 in Amsterdam, The Netherlands, by the Natuurkundig Laboratorium of the N.V. Philips Gloeilampen Fabrieken. This was done in close collaboration with the Instituut voor Kernfysisch Onderzoek (IKO) where the read-out electronics for their use in the BOL Project was developed and produced.

  13. Infrared detectors

    CERN Document Server

    Rogalski, Antonio

    2010-01-01

    This second edition is fully revised and reorganized, with new chapters concerning third generation and quantum dot detectors, THz detectors, cantilever and antenna coupled detectors, and information on radiometry and IR optics materials. Part IV concerning focal plane arrays is significantly expanded. This book, resembling an encyclopedia of IR detectors, is well illustrated and contains many original references … a really comprehensive book.-F. Sizov, Institute of Semiconductor Physics, National Academy of Sciences, Kiev, Ukraine

  14. Review of surface dose detectors in radiotherapy

    LENUS (Irish Health Repository)

    O'Shea, E.

    2006-11-20

    Several instruments have been used to measure absorbed radiation dose under non-electronic equilibrium conditions, such as in the build-up region or near the interface between two different media, including the surface. Many of these detectors are discussed in this paper. A common method of measuring the absorbed dose distribution and electron contamination in the build-up region of high-energy beams for radiation therapy is by means of parallel-plate ionisation chambers. Thermoluminescent dosimeters (TLDs), diodes and radiographic film have also been used to obtain surface dose measurements. The diamond detector was used recently by the author in an investigation on the effects of beam-modifying devices on skin dose and it is also described in this report

  15. Promessa e desafios do desenvolvimento

    OpenAIRE

    Gereffi,Gary

    2007-01-01

    A economia global tem mudado rapidamente. China, Índia e México representam casos particularmente interessantes por seus distintos modelos de desenvolvimento. O processo de consolidação global ampliou-se na década passada na esteira do rápido crescimento da China nos setores de manufatura para exportação e da entrada em cena da Índia na exportação de serviços no ramo da tecnologia de informação. A indústria do vestuário também ilustra tal tendência à consolidação, dadas as mudanças na regulaç...

  16. Evaluation of fading factor and self-dose for glass dosimeter and thermoluminescence dosimeter

    International Nuclear Information System (INIS)

    Yamasaki, T.; Yamanishi, H.; Miyake, H.; Komura, K.

    2000-01-01

    The glass dosimeter (GD) and thermoluminescence dosimeter (TLD) are both passive radiation detectors. They are often used for measuring environmental radiation. In order to measure low dose rate preciously, it is important to evaluate decreased dose due to fading and self-dose during the exposure period. We evaluate the fading factor and self-dose of thee passive detectors, GD and TLD. We select Ogoya tunnel for the experiment. The tunnel is suitable field for measuring faded dose and self-dose because it is low cosmic radiation. At the center of the tunnel, the intensity of cosmic ray is reduced to about 1/177 than the outside of the funnel. We prepared two sets of dosimeters. One set consists of five GDs, five TLDs and some pre-irradiated GDs and TLDs that are exposed to standard radiation of 4 mGy by Cs-137. These dosimeters are put in the 10 cm thick lead box in order to shield the terrestrial gamma ray. One set is located at the center of the tunnel and the other is the outside of the funnel. The dosimeters were exposed for ten months, from May 1998 to March 1999. After the exposure, the readers of dosimeters are carried into the funnel to read out the signals promptly as soon as taking out the dosimeters. As a result of the measurement, four kinds of data are taken for GD and TLD respectively. Assumed that the self-dose and cosmic ray are constant during exposure, the four independent unknown quantities, a self-dose a dose due to cosmic ray and a fading coefficient at the center of the tunnel and at the outside, are considered. Therefore four simultaneous equations should be obtained. From these examinations, the faded dose of GD is less than 1%, but that of TLD is about 16% during ten months. The coefficient for compensation of fading of GD and TLD is given as the half of the each value. At the outside of the tunnel, the measured dose rate of cosmic ray that can pass through the 10 cm lead is evaluated to be about 16 nGy/h by both detectors. The self

  17. Development and characterization of two-component albedo based neutron individual monitoring system using thermoluminescent detectors

    International Nuclear Information System (INIS)

    Martins, Marcelo Marques

    2008-01-01

    A TLD-albedo based two-component neutron individual monitoring system was developed and characterized in this work. The monitor consists of a black plastic holder, an incident neutron boron loaded shield, a moderator polyethylene body (to increase its response), two pairs of TLD-600 and TLD-700 (one pair to each component) and an adjustable belt. This monitoring system was calibrated in thermal neutron fields and in 70 keV, 144 keV, 565 keV, 1.2 MeV and 5 MeV monoenergetic neutron fields. In addition, it was calibrated in 252C f(D 2 O), 252 Cf, 241 Am-B, 241 Am-Be and 238 Pu-Be source fields. For the latter, the lower detection levels are, respectively, 0.009 mSv, 0.06 mSv, 0.12 mSv, 0.09 mSv and 0.08 mSv. The participation in an international intercomparison sponsored by IAEA with simulated workplace fields validated the system. The monitoring system was successfully characterized in the ISO 21909 standard and in an IRD - the Brazilian Institute for Radioprotection and Dosimetry - technical regulation draft. Nowadays, the neutron individual system is in use by IRD for whole body individual monitoring of five institutions, which comprehend several activities. (author)

  18. Dosimetric characteristics of radiation fields on board Czechoslovak Airlines' aircraft as measured with different active and passive detectors

    International Nuclear Information System (INIS)

    Spurney, F.; Obraz, O.; Pernicka, F.; Votockova, I.; Turek, K.; Vojtisek, O.; Starostova, V.

    1993-01-01

    Dosimetric characteristics on board Czechoslovak Airlines' aircraft (TU 154M; A310-300) were studied with different active and passive detectors (ionisation chamber RSS 112; scintillator based rate meter; GM counter based rate meter; neutron remmeter based on neutron moderation; thermoluminescence detectors, CR 39 track detectors and bubble-damage neutron detectors). Results obtained are analysed and discussed. It is estimated that the dose equivalent rates at altitudes of about 10 km are at least 3-4 μSv.h-1. Conclusions and recommendations for further studies and for radiation protection are given. (author)

  19. The NRPB automated thermoluminescent dosemeter and dose record keeping system

    International Nuclear Information System (INIS)

    Dennis, J.A.; Marshall, T.O.; Shaw, K.B.

    1975-03-01

    This report describes the thermoluminescent personal radiation dosemeter and its associated automated processing equipment, which are being developed by the National Radiological Protection Board, together with the operation of a computerised dosemeter issue and record keeping system. The main justifications for introducing these systems are improvements in the organizational efficiency of the maintenance of individual dose records, a more flexible and accurate dosimetry system, and economics in operational costs. The dosemeter is based on a numbered aluminium plate containing two lithium fluoride in polytetrafluorethylene disks for the measurement of surface and body dose. This dosemeter is wrapped in thin plastic and labelled with the wearer's name and address. On return, the dosemeter is checked automatically for radioactive contamination; it is unwrapped and evaluated; the dose readings are included in the wearer's stored dose record; the dosemeter is annealed and is then available for re-issue to another wearer. Dose reports and warnings are automatically issued to the wearer or his employer. (author)

  20. Thermoluminescence of ion-implanted SiO2

    International Nuclear Information System (INIS)

    Arnold, G.W.

    1976-01-01

    Thermoluminescence (TL) has been measured from room temperature to 500 0 C for ion-implanted fused silica glasses, crystalline synthetic quartz and rf-sputtered SiO 2 films. Measurements of the TL spectra for widely varying values of electronic and atomic energy depositions, along with the known impurity concentrations of the various systems, has allowed some of the TL features to be identified. In particular, (1) a TL peak at 150 0 C in fused silica has been identified with defects formed by structural modification, (2) a 330 0 C peak in crystalline quartz and relatively impure fused silica is tentatively assigned to a center involving Al, (3) a 100 0 C peak, common to all silicas may be related to oxygen vacancies, and (4) an approximately 200 0 C peak may be the analog of the 245 nm impurity absorption band seen in some fused silica glasses

  1. Detection of irradiated potato and garlic by thermoluminescence measurement

    International Nuclear Information System (INIS)

    Chung, H.W.; Kwon, J.H.

    1998-01-01

    Potato and garlic irradiated with gamma ray and electron beam at sprout-inhibition doses, 0.15 and 0.30 kGy were subjected to the detection whether they are irradiated or not by measuring thermoluminescence(TL) for the minerals adhering to the samples. Minerals extracted from the samples showed a high correlation coefficients between absorbed doses and corresponding TL responses. Nonirradiated samples, however, did not exhibit characteristic TL glowcurves. Major glowcurve peaks were observed at 200 to in all irradiated samples. TL intensity was proportional to irradiated doses, but it varied with the samples tested even at the same dose. It can be concluded from the results that detection of irradiated potato and garlic is possible by measuring TL for extracted minerals from the unknown samples

  2. Thermoluminescent dosimetry in computed tomography for pediatric patients

    International Nuclear Information System (INIS)

    Medrano S, A. C.; Medina A, O.; Hidalgo T, S.; Azorin N, J.

    2015-10-01

    Computed tomography (CT) in conjunction with interventional radiology, is considered as high-dose radiological procedure, so the optimization of the dose is necessary. Exposure to ionizing radiation in pediatric CT is of particular interest because the children are up to 10 times more sensitive to radiation than adults, the late somatic and genetic effects of radiation. The exposure and risk associated with ionizing radiation in CT is best characterized by the absorbed dose to each organ. Thermoluminescent dosimeters of LiF: Mg, Ti are best suited for this purpose due to its characteristics such as high sensitivity, small size and its equivalence with the tissue. The results of dose measurements -in vivo- to the three types of CT studies (skull, thorax and abdomen) are presented. These results indicate that lower doses were obtained in skull study, while the highest was one of abdomen. (Author)

  3. Thermoluminescence characterisation of chemical vapour deposited diamond films

    CERN Document Server

    Mazzocchi, S; Bucciolini, M; Cuttone, G; Pini, S; Sabini, M G; Sciortino, S

    2002-01-01

    The thermoluminescence (TL) characteristics of a set of six chemical vapour deposited diamond films have been studied with regard to their use as off-line dosimeters in radiotherapy. The structural characterisation has been performed by means of Raman spectroscopy. Their TL responses have been tested with radiotherapy beams ( sup 6 sup 0 Co photons, photons and electrons from a linear accelerator (Linac), 26 MeV protons from a TANDEM accelerator) in the dose range 0.1-7 Gy. The dosimetric characterisation has yielded a very good reproducibility, a very low dependence of the TL response on the type of particle and independence of the radiation energy. The TL signal is not influenced by the dose rate and exhibits a very low thermal fading. Moreover, the sensitivity of the diamond samples compares favourably with that of standard TLD100 dosimeters.

  4. Thermoluminescence response of gamma-irradiated sesame with mineral dust

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez L, Y. [CSIC, Instituto de Estructura de la Materia, Calle Serrano 121, 28006 Madrid (Spain); Correcher, V. [CIEMAT, Av. Complutense 22, 28040 Madrid (Spain); Garcia G, J. [CSIC, Museo Nacional de Ciencias Naturales, Calle Jose Gutierrez Abascal 2, 28006 Madrid (Spain); Cruz Z, E., E-mail: y.r.l@csic.es [UNAM, Instituto de Ciencias Nucleares, Circuito Exterior s/n, Ciudad Universitaria, 04510 Mexico D. F. (Mexico)

    2011-10-15

    The thermoluminescence (Tl) emission of minerals isolated from Mexican and Indian sesame seeds appear as a good tool to discern between irradiated and non-irradiated samples. According to the X-ray diffraction and environmental scanning microscope, the adhered dust in both samples is mainly composed by different amounts of quartz and feldspars. These mineral phases exhibit (i) enough sensitivity to ionizing radiation inducing good Tl intensity, (ii) high stability of the Tl signal during the storage of the material (i.e. low fading) and (iii) are thermally and chemically stable. Blind tests performed under laboratory conditions, but simulating industrial preservation processes (similar temperature and moisture, and presence of white light), allows to distinguish between 1 KGy gamma-irradiated and non-irradiated samples even 11000 hours (15 months) after the irradiation proceeding. (Author)

  5. Recent results on the thermoluminescence properties of diaspore

    Science.gov (United States)

    Correcher, Virgilio; Garcia-Guinea, Javier; Valle-Fuentes, Francisco José

    2003-09-01

    The presence of hydrated diaspore (α-AlOOH) on the Martian surface allows us to speculate that this material could act as: α-Al2O3 precursor and water source. In this study, new analytical data on the thermoluminescence (TL) properties of natural diaspore from Goian (Pontevedra, Spain) in the UV-blue spectral region are reported. The results indicate that it could be also used as a dosimeter for dating purposes, since it possesses an acceptable sensitivity to radiation, reproducibility, linear dose response in the studied range (up to 100 Gy), and a high stability of the relative TL emission after six months of storage. Some physical trapping parameters for each irradiated curve (trap depth, pre-exponential factor, intensity and peak position) are estimated assuming first order kinetics for the 180°C TL peak.

  6. Current status of thermoluminescence studies on minerals and rocks

    International Nuclear Information System (INIS)

    Sankaran, A.V.; Nambi, K.S.V.; Sunta, C.M.

    1982-01-01

    The usefulness of thermoluminescence (TL) in geological studies is being increasingly recognized, as may be judged from the considerable volume of literature accumulated over the past couple of decades; besides, a number of seminars, conferences and specialists' meetings have also been held on the subject of applied TL. However, these publications lie scattered over several periodicals and conference proceedings and an interested worker finds it difficult to obtain the gist of the contributions in one place. The present authors felt a need for this and have, therefore, attempted to bring together in this Report the current status of TL research about different minerals; applications in the fields of geochronology, ore-prospecting, stratigraphic correlation, geothermometry and other useful areas are also included. (author)

  7. Thermoluminescence in medical dosimetry; Termoluminiscencia en dosimetria medica

    Energy Technology Data Exchange (ETDEWEB)

    Rivera, T., E-mail: trivera@ipn.mx [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Av. Legaria 694, Col. Irrigacion, 11500 Mexico D. F. (Mexico)

    2011-10-15

    The dosimetry by thermoluminescence (Tl) is applied in the entire world for the dosimetry of ionizing radiations specially to personal and medical dosimetry. This dosimetry method has been very interesting for measures in vivo because the Tl dosimeters have the advantage of being very sensitive in a very small volume and they are also equivalent to tissue and they do not need additional accessories (for example, cable, electrometer, etc.) The main characteristics of the diverse Tl materials to be used in the radiation measures and practical applications are: the Tl curve, the share homogeneity, the signal stability after the irradiation, precision and exactitude, the response in function with the dose and the energy influence. In this work a brief summary of the advances of the radiations dosimetry is presented by means of the thermally stimulated luminescence and its application to the dosimetry in radiotherapy. (Author)

  8. Thermoluminescence results on slices from a Hiroshima tile UHFSFT03

    International Nuclear Information System (INIS)

    Stoneham, Doreen

    1987-01-01

    As was reported at the May 1984 Utah thermoluminescence (TL) workshop, high fired tiles and porcelain fragments can be sliced into 200 μm sections with constant surface area. When conventional pre-dose measurements were carried out on these slices the doses evaluated were in good agreement with results obtained by other workers using conventional quartz separation techniques. There are several advantages in using slices. First, less sample is needed as about 50 consecutive slices can be cut from a block measuring typically 1 cm 2 cross section and 2 cm in length. There are no problems with securing grains to the plate or loss of grains during measurement. Hypothetically there is less damage to the grains when they are cut slowly under cold water than when they are crushed. The disadvantage is that other minerals besides quartz are present in the slice and the signal is weaker than that obtained using quartz inclusions

  9. Auto-regenerative thermoluminescence dating using zircon inclusions

    International Nuclear Information System (INIS)

    Templer, R.H.

    1993-01-01

    Fired ceramics containing zircon inclusions have been dated by allowing the zircons to regenerate their own thermoluminescence (TL) signal, hence auto-regenerative TL dating. The technique is conceptually straightforward. One first measures the TL accrued since the last heating of the material. The zircon grains are then stored for six months and the TL signal regenerated through self-irradiation is measured. Since the internal dose-rate for zircon is dominated by the internal component the age of the sample is simply given by the ratio of the natural to auto-regenerated signal times the laboratory storage period. The technique, however, requires the measurement of a very small auto-regenerated signal, which introduces a number of experimental and physical complications. The methods for overcoming these problems and successfully dating zircons by auto-regeneration are described. (Author)

  10. Fluorescence and thermoluminescence in silicon oxide films rich in silicon

    International Nuclear Information System (INIS)

    Berman M, D.; Piters, T. M.; Aceves M, M.; Berriel V, L. R.; Luna L, J. A.

    2009-10-01

    In this work we determined the fluorescence and thermoluminescence (TL) creation spectra of silicon rich oxide films (SRO) with three different silicon excesses. To study the TL of SRO, 550 nm of SRO film were deposited by Low Pressure Chemical Vapor Deposition technique on N-type silicon substrates with resistivity in the order of 3 to 5 Ω-cm with silicon excess controlled by the ratio of the gases used in the process, SRO films with Ro= 10, 20 and 30 (12-6% silicon excess) were obtained. Then, they were thermally treated in N 2 at high temperatures to diffuse and homogenize the silicon excess. In the fluorescence spectra two main emission regions are observed, one around 400 nm and one around 800 nm. TL creation spectra were determined by plotting the integrated TL intensity as function of the excitation wavelength. (Author)

  11. Physical principles of thermoluminescence and recent developments in its measurement

    International Nuclear Information System (INIS)

    Levy, P.W.

    1974-01-01

    The physical principles which are the basis of thermoluminescence techniques for dating and authenticating archaeological and fine art objects are described in non-technical terms. Included is a discussion of the interaction of alpha particles, beta rays, i.e., energetic electrons, and gamma rays with solids, particularly electron-hole ion pair formation, and the trapping of charges by crystal imperfections. Also described is the charge-release process induced by heating and the accompanying emission of luminescence resulting from charge recombination and retrapping. The basic procedure for dating and/or authenticating an artifact is described in a ''how it is done'' manner. Lastly, recently developed apparatus is described for simultaneously measuring luminescent light intensity and wavelength and sample temperature. Examples of studies made with this ''3-D'' apparatus are given and applications to dating and authenticating are described. (U.S.)

  12. Neutron Activation Foil and Thermoluminescent Dosimeter Responses to a Lead Reflected Pulse of the CEA Valduc SILENE Critical Assembly

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Thomas Martin [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Celik, Cihangir [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Isbell, Kimberly McMahan [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Lee, Yi-kang [Commissariat a l' Energie Atomique et aux Energies Alternatives (CEA-Saclay), Gif-sur-Yvette (France); Gagnier, Emmanuel [Commissariat a l' Energie Atomique et aux Energies Alternatives (CEA-Saclay), Gif-sur-Yvette (France); Authier, Nicolas [Commissariat a l' Energie Atomique et aux Energies Alternatives (CEA-Saclay), Gif-sur-Yvette (France); Piot, Jerome [Commissariat a l' Energie Atomique et aux Energies Alternatives (CEA-Saclay), Gif-sur-Yvette (France); Jacquet, Xavier [Commissariat a l' Energie Atomique et aux Energies Alternatives (CEA-Saclay), Gif-sur-Yvette (France); Rousseau, Guillaume [Commissariat a l' Energie Atomique et aux Energies Alternatives (CEA-Saclay), Gif-sur-Yvette (France); Reynolds, Kevin H. [Y-12 National Security Complex, Oak Ridge, TN (United States)

    2016-09-01

    This benchmark experiment was conducted as a joint venture between the US Department of Energy (DOE) and the French Commissariat à l'Energie Atomique (CEA). Staff at the Oak Ridge National Laboratory (ORNL) in the US and the Centre de Valduc in France planned this experiment. The experiment was conducted on October 13, 2010 in the SILENE critical assembly facility at Valduc. Several other organizations contributed to this experiment and the subsequent evaluation, including CEA Saclay, Lawrence Livermore National Laboratory (LLNL), the Y-12 National Security Complex (NSC), Babcock International Group in the United Kingdom, and Los Alamos National Laboratory (LANL). The goal of this experiment was to measure neutron activation and thermoluminescent dosimeter (TLD) doses from a source similar to a fissile solution critical excursion. The resulting benchmark can be used for validation of computer codes and nuclear data libraries as required when performing analysis of criticality accident alarm systems (CAASs). A secondary goal of this experiment was to qualitatively test performance of two CAAS detectors similar to those currently and formerly in use in some US DOE facilities. The detectors tested were the CIDAS MkX and the Rocky Flats NCD-91. The CIDAS detects gammas with a Geiger-Muller tube, and the Rocky Flats detects neutrons via charged particles produced in a thin 6LiF disc, depositing energy in a Si solid-state detector. These detectors were being evaluated to determine whether they would alarm, so they were not expected to generate benchmark quality data.

  13. Preparation of archaeological samples for its dating by thermoluminescence

    International Nuclear Information System (INIS)

    Mejia F, D.

    2000-01-01

    The present work shows the results of the preparation of archaeological samples for their dating by thermoluminescence (Tl) using the Fine grain technique established by Zimmerman but with the varying of such preparation was realized in normal daylight conditions, only the taking of the Tl readings were realized in dark room and red light. In the chapter 1 basic concepts are described about: matter constitution, radioactivity, units and radiation magnitudes, and thermoluminescence. In the chapter 2 some theoretical aspects on dating are showed. It is described how realizing the samples collection, the fine grain method, the determination of the accumulated dose through the years or paleodoses (P=Q+I) by mean of the increasing to obtain the dose equivalent dose (Q) and the signal regeneration method to obtain the correction factor by supra linearity (1), the determination of the annual dose rate to apply the age equation and the evaluation of the age uncertainty with the error limits. The development of experimental part with samples from the archaeological site named Edzna in Campeche, Mexico is described in the chapter 3. The results are presented in the chapter 4. It was obtained an age for the sample named CH7 it was obtained an age of 389 ± years. In conclusion the preparation of the archaeological samples for their dating by Tl in the conditions before mentioned is reliable, but they must be realized more studies with samples of well known age, preparing them in normal daylight conditions and simultaneously in dark room with red light. In order to observe how respond the minerals present in the sample at different dose rapidity, the same samples must be radiated with radiation sources with different dose rate. (Author)

  14. Natural thermoluminescence of Antarctic meteorites and related studies

    Science.gov (United States)

    Benoit, Paul H.; Sears, Derek W. G.

    1998-01-01

    The natural thermoluminescence (TL) laboratory's primary purpose is to provide data on newly recovered Antarctic meteorites that can be included in discovery announcements and to investigate the scientific implications of the data. Natural TL levels of meteorites are indicators of recent thermal history and terrestrial history, and the data can be used to study the orbital/radiation history of groups of meteorites (e.g., H chondrites) or to study the processes leading to the concentration of meteorites at certain sites in Antarctica. An important application of these data is the identification of fragments, or "pairs" of meteorites produced during atmospheric passage or during terrestrial weathering. Thermoluminescence data are particularly useful for pairing within the most common meteorite classes, which typically exhibit very limited petrographic and chemical diversity. Although not originally part of the laboratory's objectives, TL data are also useful in the identification and classification of petrographically or mineralogically unusual meteorites, including unequilibrated ordinary chondrites and some basaltic achondrites. In support of its primary mission, the laboratory also engages in TL studies of modern falls, finds from hot deserts, and terrestrial analogs and conducts detailed studies of the TL properties of certain classes of meteorites. These studies include the measurement of TL profiles in meteorites, the determination of TL levels of finds from the Sahara and the Nullarbor region of Australia, and comparison of TL data to other indicators of irradiation or terrestrial history, such as cosmogenic noble gas and radionuclide abundances. Our current work can be divided into five subcategories, (a) TL survey of Antarctic meteorites, (b) pairing and field relations of Antarctic meteorites, (c) characterization of TL systematics of meteorites, (d) comparison of natural TL and other terrestrial age indicators for Antarctic meteorites, and for meteorites

  15. From films to thermoluminescence dosemeters: The Greek Atomic Energy Commission experience

    International Nuclear Information System (INIS)

    The personnel dosimetry department of the Greek Atomic Energy Commission (GAEC) assures the individual monitoring of almost 8000 occupationally exposed workers. Thermoluminescence dosimetry system replaced the existing photographic dosimetry system for the individual monitoring with the joint support of IAEA and GAEC. The thermoluminescence dosimetry system consists of two automated readers, one automated irradiator and about 20,000 dosemeters purchased from the Rados Co. The properties of two thermoluminescent materials have been compared: LiF has been chosen for the whole-body dosemeter configuration and Li 2 B 4 O 7 for the extremities. The technical evaluation of the system has been performed according to the European and IEC standards. The overall uncertainty has been calculated. The existing database system, and the accounting and dispatching procedures have been adapted to the new demands. The system became operational on March 2000, and the official distribution of thermoluminescence dosemeters has begun. (author)

  16. Thermoluminescence in alkali halides irradiated at 80K; Termoluminiscencia en haluros alcalinos irradiados a 80K

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez de Castro, M.

    1978-07-01

    The thermoluminescence, the thermally stimulated currents and the thermal stability of the F centres induced in pure NaCl and KC1 crystals by X irradiation at 80K have been studied in detail, In the range between 80 and 300K. The thermoluminescent processes induced by illumination at 80K with F light in samples previously irradiated at room temperature has also been studied. It has been clearly observed the existence of thermoluminescent processes due to electrons and holes thermally released from traps, in which the F centres are not involved. The existence of hole-F centre recombination has not been observed. There are several thermoluminescent processes in both materials which are scribed to the recombination of F centres with mobile interstitial halogen atoms thermally released from traps, which are likely monovalent impurities in this temperature interval. The light emitting stage in these processes is originated by the formation of self trapped excitons. (Author) 66 refs.

  17. NRC [Nuclear Regulatory Commission] TLD [thermoluminescent dosimeter] direct radiation monitoring network

    International Nuclear Information System (INIS)

    Struckmeyer, R.; McNamara, N.

    1989-09-01

    This report provides the status and results of the NRC Thermoluminescent Dosimeter (TLD) Direct Radiation Monitoring Network. It presents the radiation levels measured in the vicinity of NRC licensed facility sites throughout the country for the second quarter of 1989

  18. Thermoluminescence properties of micro and nano structure hydroxyapatite after gamma irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Shafaei, Mostafa; Ziaie, Farhood; Hajiloo, Nahid [Nuclear Science and Technology Research Institute, Tehran (Iran, Islamic Republic of). Radiation Application Research School

    2016-12-15

    The goal of this study is to compare the thermoluminescence properties of nano and micro structure hydroxyapatite. Nano structure hydroxyapatite was synthesized via hydrolysis method, while the micro structure one was from Merck Company. X-ray diffraction and fourier transform infrared spectroscopy were used to determine the crystal structure and chemical composition of the hydroxyapatite samples. Particles sizes of each sample were estimated using Scherer equation and transmission electron microscopy system. Thermoluminescence properties of the samples were investigated under gamma irradiation. The glow curves of micro and nano structure samples show a peak at 150 C and 200 C, respectively. Thermoluminescence responses of both the samples were linear in the range of 25 - 1 000 Gy where, nano structure sample show a greater slope and stronger linearity in comparison to the micro sample. The results show that the thermoluminescence response of micro sample faded rapidly in comparison to the nano sample due to the existence of the peak at higher temperature.

  19. Measurement conditions of natural soil thermoluminescence and their application in a granite type uranium deposit

    International Nuclear Information System (INIS)

    Chen Yue; Yang Yaxin; Liu Qingcheng

    2009-01-01

    A measuring method of natural soil thermoluminescence is used for prospecting of uranium deposits. The better effects are obtained by using the method, but the parameters selected have significant effects on the intensity of soil thermoluminescent. So, the measuring parameters are selected according to the different soil samples. Based on the measuring 1 000 soil samples of granite type uranium deposit,the optimum heating up program of natural soil thermoluminescence is obtained, that is, preheating, lasting heating, constant temperature and the halting heating. The parameters selected are as follows: the heating rate being 15 degree C/s, the temperatures of the first and second constant temperature being 135 degree C and 400 degree C respectively. Using the selected parameters for measuring soil samples from a known mining area in Guangdong province, the result indicates that the abnormities of thermoluminescence have corresponding relations with the underground orebodies. (authors)

  20. Analysis of the thermoluminescent signal in the hydroxyapatite synthesized by the sol-gel method

    International Nuclear Information System (INIS)

    Mendoza A, D.; Gonzalez, P.R.; Lobato, M.; Rubio, E.; Rodriguez L, V.; Custodio, E.

    2004-01-01

    The physical properties of the ceramics are related with the chemical bonds and the crystalline structure, because the elements that constitute it can be united by ionic bonds or partially ionic giving a covalent character, this last causes that the outer layer is full of electrons. This property makes that the ceramic ones become interesting materials for thermoluminescent applications, as it demonstrates through the recent works presented on the hydroxyapatite that is a ceramic biomaterials that has shown an interesting thermoluminescent signal when being exposed to gamma radiation. In this sense, this work presents the thermoluminescent signal analysis induced by the UV and gamma radiation in a particular type of hydroxyapatite synthesized by sol gel method in which the temperature synthesis is varied. The final thermoluminescent sensitivity of materials is correlated with the crystalline degree, which is analysed through X-ray diffraction. (Author)

  1. Modulation of the thermoluminescence glow curve of sol-gel synthesized SiO{sub 2} and Si O-2:Eu through thermal annealing

    Energy Technology Data Exchange (ETDEWEB)

    Salas J, Ch. J.; Cruz V, C. [Universidad de Sonora, Departamento de Investigacion en Polimeros y Materiales, Apdo. Postal 130, 83000 Hermosillo, Sonora (Mexico); Bernal, R. [Universidad de Sonora, Departamento de Investigacion en Fisica, Apdo. Postal 5-088, 83190 Hermosillo, Sonora (Mexico); Castano, V. M., E-mail: salasjuarez@gimmunison.com [UNAM, Centro de Fisica Aplicada y Tecnologia Avanzada, Apdo. Postal 1-1010, 76000 Queretaro, Qro. (Mexico)

    2015-10-15

    Full text: Due to the increasing use of ionizing radiations, is necessary to monitor the radiation fields and exposure doses in facilities in which they are used. Different facilities or applications involve the use of different radiation and doses, and the sort of needed dosimetry also varies. Sometimes a conventional thermoluminescence (Tl) dosimetry satisfy the requirements since the record of the accumulated dose in a time interval is enough, but other cases could require for real-time measurement of a radiation field, being required a non-Tl dosimetric technique. On the other hand, different applications involve the use of different dose ranges, and so dosimeters with different sensitivities are needed. To solve the diverse needs of radiation detectors and dosimeters, a lot of phosphors materials has been characterized concerning their dosimetric capabilities. For medical application, biocompatible materials are desirable. In this work, we present experimental evidence that Sol-Gel synthesized SiO{sub 2} and SiO{sub 2}:Eu phosphors exhibit Tl glow curves composed by the superposition of several individual glow peaks each located at different temperature ranging from values below 100 up to temperatures greater than 400 degrees C, whose relative sensitivities can be modified by subjecting the phosphors to different thermal annealing. By modulating the relative intensities of the individual Tl peaks, glow curves with different shapes are obtained in such a way that SiO{sub 2} and SiO{sub 2}:Eu can be used to develop dosimeters useful for different dose ranges, and for both, conventional thermoluminescence dosimetry and non-thermoluminescence afterglow-based) dosimetry. (Author)

  2. Correlation of radiation induced cellular signal transduction events with LET-selective thermoluminescence dosimetry

    International Nuclear Information System (INIS)

    Fuerweger, C.; Hajek, M.; Vana, N.; Kodym, R.; Okayasu, Ryuichi

    2006-01-01

    In order to obtain a deeper insight into the molecular mechanism controlling the cellular response to high-linear energy transfer (LET) radiation we observed early signal transduction events after low dose exposure to charged particles. Normal human fibroblasts were irradiated with ions of varying energy and LET (Helium, Carbon, Neon, Silicon and Iron, from 2, 2 up to 300 keV/μm) at the National Institute of Radiological Sciences (NIRS)-Heavy Ion Medical Accelerator in Chiba (HIMAC)-facility. For exposure, a low particle fluence of approx. 7, 3 * 10 4 particles/cm 2 (corresponding to 1 hit nucleus in 7 cells) was chosen. Doses and LET were verified with thermoluminescence detectors (LiF: Mg, Ti) evaluated according to the high-temperature-ratio (HTR)-method. In FY 2005, we focused on investigating the activation of ataxia telangiectasia mutated (ATM) and several of its substrates 2-3 hours after irradiation using immunofluorescence and immunohistochemical staining techniques. So far, we found that the number of pATM (S1981)-foci per nucleus was higher in cells irradiated with higher-LET beams. Especially Fe-ions (500 MeV/u) yielded twice the number of foci than mock or He (150 MeV/u) irradiated cells. Furthermore, for Fe-ions the number of cells with radiation induced γH2aX-foci exceeded the number of cells with nucleus hits, indicating a bystander effect. These data show that the early cellular response to high-LET radiation is modulated by the energy deposition of the particle. (author)

  3. Thermoluminescence of europium-doped zinc oxide exposed to beta particle irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Iriqui R, J. L.; Cruz V, C. [Universidad de Sonora, Departamento de Investigacion en Polimeros y Materiales, Apdo. Postal 130, 83000 Hermosillo, Sonora (Mexico); Bernal, R. [Universidad de Sonora, Departamento de Investigacion en Fisica, Apdo. Postal 5-088, 83000 Hermosillo, Sonora (Mexico); Castano, V. M., E-mail: jorgeiriqui@gimmunison.com [UNAM, Instituto de Fisica, Centro de Fisica Aplicada y Tecnologia Avanzada, Apdo. Postal 1-1010, 76000 Queretaro, Qro. (Mexico)

    2015-10-15

    Full text: Zn O is a promising material for a range of optoelectronics applications, due to its direct wide band gap (E{sub g} ∼3.3 eV at 300 K) and large exciton binding energy (60 MeV). Its applications include UV light emitters, varistors, surface acoustic wave devices, piezoelectric transducers, and chemical and gas sensing. Rare-earth activation of phosphors has long been seen as an effective process since coupling energy into the rare-earth-ion site, either by ionization, charge exchange or a resonance energy process, results in light production. It is reported that Europium modifies the response thermoluminescence (Tl) for pure zinc oxide, when is irradiated with X-ray, created a peak at 365 degrees C. In this work, Zn O:Eu phosphors were synthesized by a chemical method. Some samples were exposed to beta particle irradiation for doses ranging from 1 up to 100 Gy. Tl response as a function of dose is linear throughout the studied dose range. The glow curve exhibits three maxima, centered at 176, 279 and 340 degrees C. The reusability studies obtained after ten repeated cycles of annealing irradiation readout for the Zn O:Eu shows that the variation in the Tl response is ten percent and tends to stabilization. The results indicate that these new Zn O:Eu phosphors are promising detectors and dosimeters for beta radiation. The structural and morphological characterization was carried out by X-ray diffraction and scanning electron microscopy, respectively. (Author)

  4. Experiences of using thermoluminescent dosimeter (TLD) in KUR (Kyoto University Reactor)

    International Nuclear Information System (INIS)

    Furubayashi, Toru; Kanda, Keiji

    1979-01-01

    It has been decided to employ TLDs to measure γ dose in the mixed field of neutrons and γ-ray in the KUR, which has excellent properties such as compact size, light weight, highly sensitive and simple in handling. Thus, the γ dosimetry with Mg 2 SiO 4 (Tb) has been standardized along with thermal neutron dosimetry (using Au foil and Cd cover). The advantages of TLDs are cleanliness and unbreakability in addition to those described above. The shortcoming is that the reading is limited once for all as they are integral type detectors. The element is the polyethylene tube of 1 mm diameter and about 10 mm long fused and sealed at both ends, containing Mg 2 SiO 4 powder, and the thermoluminescence is measured by taking the powder out of the tube. It was found that the Mg 2 SiO 4 (Tb) element sealed in a polyethylene tube has the sensitivity to fast neutrons. This is caused by recoil protons from the polyethylene wall, and it necessitates to look over again the γ measurement in the mixed field with fast neutrons. Also, commercially available TLD elements have been adopted because their stability was improved. The BeO element enclosed in a 6 LiF case has been selected, because its effective atomic number was 7.6, close to 7.4 of living body, and its sensitivity to thermal neutrons is small. At present, the Mg 2 SiO 4 (Tb) sealed in a polyethylene tube or the BeO in a 6 LiF case is used properly depending on applications. (Wakatsuki, Y.)

  5. Self: um conceito em desenvolvimento

    Directory of Open Access Journals (Sweden)

    Lídia Suzana Rocha de Macedo

    2012-08-01

    Full Text Available Diversas definições de self coexistem nas teorias e práticas psicológicas. Essa variedade é resultante de bases epistemológicas a partir das quais se adotam estratégias diferentes para abordar e demarcar os limites do objeto em questão e descrevê-lo. Este estudo teve como objetivo oferecer uma revisão dos conceitos de self e uma reflexão sobre como esse conceito se articula nas diferentes abordagens teóricas da psicologia. Destaca-se que dilemas centrais à psicologia do desenvolvimento atravessam o conceito de self. Por essa razão, apresenta-se a tese de que, ao analisar cada definição de self, deve-se buscar responder como cada teoria colocou-se diante das dicotomias estabilidade versus transformação, específico versus universal e mundo interno versus mundo externo.

  6. Thermoluminescence system CaF sub 2 Tm models, dosimetric properties and applications

    CERN Document Server

    Summerer, L M

    2002-01-01

    In parallel with the increasing level of exposure to ionizing radiation in modern society, dosimeters to measure absorbed doses were developed and studied. One of the most widespread systems are thermoluminescence crystals. The history of thermoluminescence dosimetry is a history of success. Since decades, hundreds of publications appear every year on the large topic of thermoluminescence dosimetry. A majority of them deals with LiF:Mg,Ti, the by far most widely used and studied thermoluminescent crystal. In this work, we are going to analyze in detail the properties of a different thermoluminescence dosimetry system, CaF sub 2 :Tm, rarely used and scarcely described. Most of the theoretical models explaining the physical processes involved in thermoluminescence are based on LiF:Mg,Ti crystals. The major models are reviewed and their applicability to CaF sub 2 :Tm is examined. On the basis of results, obtained with the spectral analysis of the TL light after irradiation with different heavy ions, a new theore...

  7. Transmutation detectors

    Czech Academy of Sciences Publication Activity Database

    Viererbl, L.; Lahodová, Z.; Klupák, V.; Sus, F.; Kučera, Jan; Kůs, P.; Marek, M.

    2011-01-01

    Roč. 632, č. 1 (2011), s. 109-111 ISSN 0168-9002 Institutional research plan: CEZ:AV0Z10480505 Keywords : Transmutation detector * Activation method * Neutron detector * Neutron fluence Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.207, year: 2011

  8. Vapor Detector

    Science.gov (United States)

    Waddell, H. M.; Garrard, G. C.; Houston, D. W.

    1982-01-01

    Detector eliminates need for removing covers to take samples. Detector is canister consisting of screw-in base and clear plastic tube that contains two colors of silica gel. Monoethylhydrazine and nitrogen tetroxide vapors are visually monitored with canister containing color-changing gels.

  9. Thermoluminescence, luminescence optically stimulated and creation of defects in alkaline halogenides contaminated with Europium; Termoluminiscencia, luminiscencia opticamente estimulada y creacion de defectos en halogenuros alcalinos contaminados con Europio

    Energy Technology Data Exchange (ETDEWEB)

    Barboza F, M. [Centro de Investigacion en Fisica, Universidad de Sonora, Apartado Postal 5-088, 83190 Hermosillo, Sonora (Mexico)

    1999-07-01

    The alkaline halogenides have been subject matter of investigations related with the search of sensor materials for X-ray bidimensional images or optical memories. The understanding of the damage formation processes generated by ionizing and non-ionizing radiations is important for the correct design of devices that working as detectors and dosemeters of both type of radiations. In this work we present the investigation results related with the defects produced by the ionizing radiation type X and ultraviolet light in the range of 200-360 nm in crystals of KCl: Eu{sup 2+} and KBr:Eu{sup 2+}. It is examined the thermoluminescence and luminescence spectra with the purpose of identifying the exciton processes, owing to the excitation of the halogenide ions in which the primary defects correspond to the F and H centers. It has been found that the 400-600 nm emission is associated with the luminescence type that in his turn can be associated with autotrapped excitons perturbed by the impurity. On the other hand, it is examined the emission spectra of the luminescence optically stimulated in crystals of KBr: Eu{sup 2+} and KCl: Eu{sup 2+} finding too that such materials would be used as optical memories susceptible of to store information, and through of photostimulation to read this. It was determined that the F centers participate in the luminescence optically stimulated in these crystals, as well as too in the recombination processes responsible by the thermoluminescent emission. (Author)

  10. A teoria do “desenvolvimento fragmentador”

    Directory of Open Access Journals (Sweden)

    Fred Scholz

    2010-04-01

    Full Text Available O pensamento desenvolvimentista do passado era dominado pela ideia de que o subdesenvolvimento do Terceiro Mundo poderia ser superado mediante ajuda técnica, financeira e pessoal dos países do Norte. A meta era alcançar o nível de desenvolvimento dos países ocidentais industrializados por meio de um desenvolvimento retardatário. Na base dessa ideia estava, por um lado, o consenso de valores ocidental-humanitários, que, o mais tardar desde a época do Esclarecimento, determinou o pensar e o devir social. Por outro lado, a ideia baseou-se na responsabilidade histórica (surgida das condições da Guerra Fria, aceita política e socialmente do "Ocidente" para com os chamados países em desenvolvimento, na sua maioria ex-colônias. Argumenta-se, neste artigo, que a ideia de um desenvolvimento retardatário deve, na era da globalização, ser substituída pelo fato de um desenvolvimento fragmentador.

  11. Nutrição e desenvolvimento

    Directory of Open Access Journals (Sweden)

    Arruda Ilma K. G. de

    1994-01-01

    Full Text Available As discussões sobre desenvolvimento e nutrição freqüentemente se realizam sob um duplo enfoque: aqueles que consideram o estado nutricional como reflexo do desenvolvimento, e os que admitem que a nutrição influencia fortemente no nível e ritmo desse desenvolvimento. Os autores focalizam o tema visualizando a nutrição como um fator decisivo para um bom desenvolvimento social e econômico, particularizando o fato de que as intervenções nutricionais podem contribuir para melhorias significativas nos resultados escolares, na produtividade do trabalho e na resistência às infecções. Assim, os reflexos da desnutrição na economia seriam evidentes: quer pelas limitações na expectativa de renda, quer pelo aumento dos custos dos compromissos que a população assume para proteger-se, quer pelos avultados custos ocultos de origem social - absenteísmo, acidentes do trabalho e rotatividade de pessoal. Em face dos propósitos de modernização e competitividade da economia, é inquestionável a necessidade da nutrição figurar bem alto na lista de prioridades nacionais. Com isso, promover-se-ia o desenvolvimento dos recursos humanos e a preservação desse capital, que é o ideário de uma economia socialmente responsável.

  12. Cryogenic detectors

    International Nuclear Information System (INIS)

    Zehnder, A.

    1987-01-01

    Presently the development of new large scale detector systems, used in very high energy physics experiments, is very active. In the low energy range, the introduction of charge coupled devices allows improved spacial and energy resolution. In the keV region, high resolution can only be achieved via the well established diffraction spectrometers with the well-known disadvantage of a small throughput. There exist no efficient detectors for non-ionizing radiation such as coherent nuclear scattering of weakly interacting particles. The development of high resolution solid state detectors in the keV-region with the possibility of nuclear recoil detection is therefore highly desired. Such detectors applied in astro and particle physics would thus allow one to obtain new information not achievable otherwise. Three types of cryogenic detectors exist: Calorimeters/Bolometers. This type is sensitive to the produced excess phonons and measures the deposited energy by detecting the heat pulses. Excess charge carriers should be used to produce phonons. Tunneling junctions. This type is sensitive to excess charge produced by the Cooper pair breakup. Excess phonons should be used to break up Cooper pairs. Superheated superconducting granules (SSG). An SSG detector consists of granules, the metastability of which is disturbed by radiation. The Meissner effect then causes a change in the field distribution of the applied external field, which can be detected. The present paper discusses the basic principle of calorimetric and tunneling junction detectors and some of their applications. 26 refs., 7 figs., 1 tab

  13. Detectors - Electronics

    International Nuclear Information System (INIS)

    Bregeault, J.; Gabriel, J.L.; Hierle, G.; Lebotlan, P.; Leconte, A.; Lelandais, J.; Mosrin, P.; Munsch, P.; Saur, H.; Tillier, J.

    1998-01-01

    The reports presents the main results obtained in the fields of radiation detectors and associated electronics. In the domain of X-ray gas detectors for the keV range efforts were undertaken to rise the detector efficiency. Multiple gap parallel plate chambers of different types as well as different types of X → e - converters were tested to improve the efficiency (values of 2.4% at 60 KeV were reached). In the field of scintillators a study of new crystals has been carried out (among which Lutetium orthosilicate). CdTe diode strips for obtaining X-ray imaging were studied. The complete study of a linear array of 8 CdTe pixels has been performed and certified. The results are encouraging and point to this method as a satisfying solution. Also, a large dimension programmable chamber was used to study the influence of temperature on the inorganic scintillators in an interval from -40 deg. C to +150 deg. C. Temperature effects on other detectors and electronic circuits were also investigated. In the report mentioned is also the work carried out for the realization of the DEMON neutron multidetector. For neutron halo experiments different large area Si detectors associated with solid and gas position detectors were realized. In the frame of a contract with COGEMA a systematic study of Li doped glasses was undertaken aiming at replacing with a neutron probe the 3 He counters presently utilized in pollution monitoring. An industrial prototype has been realised. Other studies were related to integrated analog chains, materials for Cherenkov detectors, scintillation probes for experiments on fundamental processes, gas position sensitive detectors, etc. In the field of associated electronics there are mentioned the works related to the multidetector INDRA, data acquisition, software gamma spectrometry, automatic gas pressure regulation in detectors, etc

  14. Alumina as a thermoluminescent material for personnel dosimetry

    International Nuclear Information System (INIS)

    Beinsteiner, J.

    1980-06-01

    In this paper the possible use of aluminium for dosimeters is investigated. The thermoluminescence recovery should be enhanced by different forms of doping and the form of the dosimeter should give reproductable results. Doping was done by coprecipitation of the additive with an Al salt from aqueous solutions and then converting to the oxides by heating. Doping with 850 ppm Tb 2 O 3 gives a 50 fold enhancement of the sensitivity. The emission of light is in the blue range. The use of PTFE for matrix material is strongly restricted because PTFE absorbes too much of the blue light. Sintering in vacuum or in hydrogen converts Tb 4 O 7 into Tb 2 O 3 and the reaction Tb(III)-radiation, heat-Tb(II) activates the luminescence. Tablets of these material produced by sintering in hydrogen with peaks at 125 and 72 0 C are 13 times as sensitive as LiF (TLD-100) and are linear in the range till 5000R. Fading in one month is 20% but loss of information is 13% after the first day. An apparatus was built which allows a semiautomatical evaluation of 50 dosimeters. (P.W.)

  15. Developments in production of silica-based thermoluminescence dosimeters

    Science.gov (United States)

    Bradley, D. A.; Siti Shafiqah, A. S.; Siti Rozaila, Z.; Sabtu, Siti Norbaini; Abdul Sani, S. F.; Alanazi, Abdulaziz H.; Jafari, S. M.; Amouzad Mahdiraji, G.; Mahamd Adikan, F. R.; Maah, M. J.; Nisbet, A. N.; Tamchek, N.; Abdul Rashid, H. A.; Alkhorayef, M.; Alzimami, K.

    2017-08-01

    This work addresses purpose-made thermoluminescence dosimeters (TLD) based on doped silica fibres and sol-gel nanoparticles, produced via Modified Chemical Vapour Deposition (MCVD) and wet chemistry techniques respectively. These seek to improve upon the versatility offered by conventional phosphor-based TLD forms such as that of doped LiF. Fabrication and irradiation-dependent factors are seen to produce defects of differing origin, influencing the luminescence of the media. In coming to a close, we illustrate the utility of Ge-doped silica media for ionizing radiation dosimetry, first showing results from gamma-irradiated Ag-decorated nanoparticles, in the particular instance pointing to an extended dynamic range of dose. For the fibres, at radiotherapy dose levels, we show high spatial resolution (0.1 mm) depth-dose results for proton irradiations. For novel microstructured fibres (photonic crystal fibres, PCFs) we show first results from a study of undisturbed and technologically modified naturally occurring radioactivity environments, measuring doses of some 10 s of μGy over a period of several months.

  16. Import control of irradiated foods by the thermoluminescence method

    International Nuclear Information System (INIS)

    Pinnioja, S.; Autio, T.; Niemi, E.; Pensala, O.

    1993-01-01

    A thermoluminescence (TL) method was applied for the import control of irradiated foods. The method is based on the determination of the TL of mineral contaminants in foods. Detection of irradiation was incorporated in official Finnish control procedures in spring 1990. For foodstuffs with a reduced microbe content and in which no fumigant residues are found, possible irradiation is investigated by the TL method. The minerals are separated from the foods in different ways: picking is used for spices; water rinsing for herbs, spices, berries and mushrooms; high-density liquid to separate the organic material from the mineral fraction in seafood; and carbon tetrachloride for foods forming gels with water. To date about 140 food samples have been analysed for control purposes: 50 samples of herbs and spices, 25 samples of berries and mushrooms and 65 samples of seafood. Of these, 14 samples of herbs and spices and 5 samples of seafood were shown to have been irradiated. Differences in TL intensity between irradiated and unirradiated samples were at least 1 and usually 3-4 orders of magnitude. (orig.)

  17. tgcd: An R package for analyzing thermoluminescence glow curves

    Directory of Open Access Journals (Sweden)

    Jun Peng

    2016-01-01

    Full Text Available Thermoluminescence (TL glow curves are widely used in dosimetric studies. Many commercial and free-distributed programs are used to deconvolute TL glow curves. This study introduces an open-source R package tgcd to conduct TL glow curve analysis, such as kinetic parameter estimation, glow peak simulation, and peak shape analysis. TL glow curves can be deconvoluted according to the general-order empirical expression or the semi-analytical expression derived from the one trap-one recombination center (OTOR model based on the Lambert W function by using a modified Levenberg–Marquardt algorithm from which any of the parameters can be constrained or fixed. The package provides an interactive environment to initialize parameters and offers an automated “trial-and-error” protocol to obtain optimal fit results. First-order, second-order, and general-order glow peaks (curves are simulated according to a number of simple kinetic models. The package was developed using a combination of Fortran and R programming languages to improve efficiency and flexibility.

  18. Entrance surface dose measurements in mammography using thermoluminescence technique

    International Nuclear Information System (INIS)

    Rivera, T.; Vega C, H.R.; Manzanares A, E; Azorin, J.; Gonzalez, P.R.

    2007-01-01

    Full text: Of the various techniques that can be used for personnel dosimetry, thermoluminescence dosimetry (TLD) has emerged as a superior technique due to its manifold advantages over other methods of dose estimation. Various phosphors have been therefore investigated regarding their suitability for dosimetry. In this paper, a dosimetry system based on thermally stimulated luminescence (TSL) from zirconium oxide phosphors embedded in polytetrafluorethylene (ZrO 2 +PTFE) was developed for entrance surface doses (ES) measurements in mammography. Small ZrO 2 pellets of 5 mm in diameter and 0.8 mm in thickness were used. The reproducibility of measurements and linearity of ZrO 2 were also studied. The results were compared with those obtained from LiF:Mg,Cu,P usually used for the determination of absorbed dose in mammography. Measurements both per unit air kerma and In vivo were performed using a mammography unit model DMR (General Electric). The results showed that ZrO 2 TLDs can be used for the same X-ray dosimetry applications as LiF:Mg,Cu,P, with each type having the disadvantage of a response dependent on energy, particularly at low energies. These results indicate a considerable potential for use in routine control and In vivo ES measurements in mammography. (Author)

  19. Theory of thermoluminescence gamma dose response: The unified interaction model

    Science.gov (United States)

    Horowitz, Y. S.

    2001-09-01

    We describe the development of a comprehensive theory of thermoluminescence (TL) dose response, the unified interaction model (UNIM). The UNIM is based on both radiation absorption stage and recombination stage mechanisms and can describe dose response for heavy charged particles (in the framework of the extended track interaction model - ETIM) as well as for isotropically ionising gamma rays and electrons (in the framework of the TC/LC geminate recombination model) in a unified and self-consistent conceptual and mathematical formalism. A theory of optical absorption dose response is also incorporated in the UNIM to describe the radiation absorption stage. The UNIM is applied to the dose response supralinearity characteristics of LiF:Mg,Ti and is especially and uniquely successful in explaining the ionisation density dependence of the supralinearity of composite peak 5 in TLD-100. The UNIM is demonstrated to be capable of explaining either qualitatively or quantitatively all of the major features of TL dose response with many of the variable parameters of the model strongly constrained by ancilliary optical absorption and sensitisation measurements.

  20. Thermoluminescence studies of natural and doped calcium fluoride phosphors

    International Nuclear Information System (INIS)

    El Kolaly, M.A.

    1977-01-01

    The various aspects of thermoluminescence (TL) of calcium fluoride phosphors obtained both from natural and laboratory-grown CaF 2 crystals have been investigated in the temperature range from room temperature to 750 deg C. Dopants used in these studies were Mn, Y and lanthanide series rare earths. The aspects which have been investigated are : (1) effect of single and double doping on TL glow curves and TL emission spectra after gamma irradiation, (2) TL traps : their kinetics including evaluation of the activation energy using different techniques, their decay kinetics and their behaviour under partially filled conditions, and (3) effect of temperature on emission of intensity of X-ray induced luminescence and TL. During the course of these investigations, a new glow peak was observed at 650 deg C in natural CaF 2 . It was found that this peak could also be produced in synthetic CaF 2 doped with (Y + Sm). A new model for the TL trap has also been proposed. (M.G.B.)

  1. Thermoluminescence of Z1 centres in Sr-doped KCl

    International Nuclear Information System (INIS)

    Kamavisdar, V.S.; Moholkar, S.C.; Deshmukh, B.T.

    1980-01-01

    It is well known for alkali halides doped with divalent metal impurities that exposure to high energetic radiation and subsequent F band bleaching leads to the formation of Z 1 centres. Optical absorption measurements have shown that a low concentration of Z 1 centres is produced along with F centres during irradiation without any optical bleaching. Now the question is whether Z 1 centres are really formed along with F centres during irradiation. The aim of the present paper was to study the formation of a small amount of Z 1 centres during irradiation with the help of optical absorption and thermoluminescence measurements. The crystals of KCl:Sr were exposed to γ-rays for different doses. The TL curve for the crystal exposed to a minimum dose of γ-rays shows a TL peak at 457 K and a weak shoulder in the region 400 K to 408 K. The TL curve of the crystal exposed to maximum dose of rays shows the peak at 408 K with a greater intensity. Upon F band bleaching 408 K peak increases in intensity and optical absorption is also broadened. It is shown that the peak at 457 K is due to F centres and the peak at 408 K is due to Z 1 centres. These results clearly show that a small anount of Z 1 centres is really formed along with F centres during irradiation. (author)

  2. Thermoluminescent analysis of archaeological ceramic from Teotenango, Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Dominguez R, R. [Centro INAH Estado de Mexico, Morelos Ote. 502, Col. San Sebastian, 50090 Toluca, Estado de Mexico (Mexico); Mondragon, M. [Museo Roman Pina Chan, Teotenango 1024 (Mexico); Villa S, G.; Gonzalez M, P.R.; Mendoza A, D. [ININ, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2006-07-01

    Of all the kind of artifacts which may be found at archaeological sites, ceramics are surely among the most important. A ceramic material is highly durable, and virtually unchanged after hundred of years from its date of manufacture. Because of this, a ceramic will always be an important object for serious studies to determine which culture produced it, to date cultures, reconstruct economic patterns and social organization, and establish routes of trade or simply to classify the different types of ceramics. The aim of this paper was to perform a thermoluminescent analysis of archaeological ceramic samples belonging to Teotenango, Mexico. The analysis is complemented with a physicochemical characterization by Scanning Electron Microscopy (SEM), Energy Dispersive X-ray Spectroscopy (EDS), X-Ray Diffraction (XRD). TL analysis shows some differences when the samples are exposed to ionizing radiation field, while SEM analysis shows a porous and granular structure in all samples, EDS analysis shows oxygen (O), aluminum (Al), silicon (Si), iron (Fe), sodium (Na), phosphorus (P), potassium (K) and calcium (Ca) in significant amounts. These results allow establishing differences among ceramic samples belonging to the same place. (Author)

  3. An algorithm for unified analysis on the thermoluminescence glow curve

    International Nuclear Information System (INIS)

    Chung, K.S.; Park, C.Y.; Lee, J.I.; Kim, J.L.

    2014-01-01

    An algorithm was developed to integrally handle excitation by radiation, relaxation and luminescence by thermal or optical stimulation in thermoluminescence (TL) and optically stimulated luminescence (OSL) processes. This algorithm reflects the mutual interaction between traps through a conduction band. Electrons and holes are created by radiation in the beginning, and these electrons move to the trap through the conduction band. These holes move to the recombination center through a valence band. The ratio of the electrons allocated to each trap differs with the recombination probability and these values also relevant to the process of luminescence. Accordingly, the glow curve can be interpreted by taking the rate of electron–hole pairs created by ionizing radiation as a unique initial condition. This method differs from the conventional method of interpreting the measured glow curve with the initial electron concentration allocated to each trap at the end of irradiation. A program using the Visual Studio's C# subsystem was made to realize such a developed algorithm. To verify this algorithm it was applied to LiF:Mg,Cu,Si. The TL glow curve was deconvoluted with a model of five traps, one deep trap and one recombination center (RC). - Highlights: • TL glow curve deconvolution employing interacting model. • Simulation both irradiation and TL readout stages for various dose level. • Application in the identification TL kinetics of LiF:Mg,Cu,Si TLD

  4. Thermoluminescence and photostimulated luminescence techniques to identify irradiated foods

    Energy Technology Data Exchange (ETDEWEB)

    Schreiber, G.A. [BgVV - Federal Inst. for Health Protection of Consumers and Veterinary Medicine, Berlin (Germany). Food Irradiation Lab.

    1996-12-31

    Since the publication of the first report about increased thermoluminescence (TL) of irradiated spices, 10 years have passed. At that time, this effect was observed when spices were heated in a TL reader. Meanwhile, the light sources within the foods have been identified and TL methods applied to various foods for identification of irradiation treatment. The methods have been approved by the Ministry of Agriculture, Fisheries and Food (MAFF) of the United Kingdom and included in the Official Collection of Methods according to article 35 of the German Foods Act (LMBG). A draft European Standard has been formulated for approval by the member states of the European Committee for Standardization (CEN) and most importantly, the method is already routinely used food control authorities to identify irradiation treatment of foods. The strength of TL is its radiation specificity. It counts among the most reliable methods and there is potential for becoming the most sensitive physical method for detection of irradiated foods. Research is still going on to speed up performance, to find new applications and to decrease detection limits. Most recently, a new luminescence technique -photostimulated luminescence - has been introduced which can be rapidly performed and which seems to have the potential to be applied to a similar broad range of foods as TL. (author).

  5. Measurement of doses to aviator pilots using thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Azorin N, J.; Cruz C, D.; Rivera M, T.

    2004-01-01

    During the development of their work, the aviator pilots are exposed at high levels of natural radiation of bottom caused mainly by the cosmic radiation of galactic origin and lot. For such reason, the Metropolitan Autonomous University (UAM) and the Union Association of Aviator Pilots (ASPA), subscribed an agreement with the purpose of to measure the doses of ionizing radiation received by the aviator pilots of diverse air companies that man different types of airships and to determine if these doses surpass the one limit of 0.11 mSv/h settled down by the IAEA for the public in general; and if therefore, these workers should be considered as personnel occupationally exposed. In this work the obtained results when measuring the absorbed dose received by Mexican civil aviator pilots during the development of their work, using thermoluminescent dosemeters of LiF:Mg,Cu,P + Ptfe of national production are presented. The obtained results during the years of 2001 and 2002 show that the monthly doses received by the pilots surpass the one it limits established for the public in general, for what they should be considered as personnel occupationally exposed. (Author)

  6. New laser technique revives old ideas for thermoluminescence neutron dosimetry

    International Nuclear Information System (INIS)

    Braeunlich, P.; Brown, M.; Gasiot, J.; Fillard, J.P.

    1982-01-01

    Laser heating is discussed as a means to evaluate thermoluminescence dosimeters in neutron dosimetry. Direct energy coupling from the photon beam to the phonons of the TL material permits heating of thin layers with rates of temperature increase exceeding 10 4 Ks - 1 . Rapid TLD evaluation will allow the design of dosimetry badges containing a number of different small thin film TLD elements in various orientations and behind appropriate filters, hydrogenous radiators, etc. Desired redundance is readily possible by using back-up TLDs for every specific task. Reading occurs with a scanning laser beam rather than by mechanically manipulating the TLD toward a fixed heat source. Improvements in the signal-to-noise ratio of up to a factor of 1000 are readily obtained. Thus, sensitive thin-film TLDs can be designed with negligible self-shielding for thermal neutrons in albedo applications and with known, nearly energy dependent cavity correction factors for dosimetry in mixed n-#betta# fields. Due to the greatly increased sensitivity possible with fast laser heating, significant advances are expected in the fast neutron dosimetry techniques which are based on hydrogeneous proton radiators or LET-dependent slow peak formation

  7. Dose measurements in intraoral radiography using thermoluminescent dosimeters

    International Nuclear Information System (INIS)

    Azorín, C; Rivera, T; Azorín, J; Aguirre, F

    2015-01-01

    The use of X-ray in medicine demands to expose the patient and the professional to the lowest radiation doses available in agreement with ALARA philosophy. The reference level for intraoral dental radiography is 7 mGy and, in Mexico, a number of examinations of this type are performed annually. It is considered that approximately 25% of all the X-rays examinations carried out in our country correspond to intraoral radiographies. In other hand, most of the intraoral X-ray equipment correspond to conventional radiological systems using film, which are developed as much manual as automatically. In this work the results of determining the doses received by the patients in intraoral radiological examinations made with different radiological systems using LiF:Mg,Cu,P+PTFE thermoluminescent dosimeters are presented. In some conventional radiological systems using film, when films are developed manual or automatically, incident kerma up to 10.61 ± 0.74 mGv were determined. These values exceed that reference level suggested by the IAEA and in the Mexican standards for intraoral examinations

  8. Thermoluminescent dose measurements on board Salyut type orbital stations

    International Nuclear Information System (INIS)

    Akatov, Yu.A.; Arkhangelskij, V.V.; Aleksandrov, A.P.

    1984-06-01

    A small, vibration- and shock-resistant thermoluminescent dosemeter (TLD) system - named PILLE - was developed for orbital stations at the Central Research Institute for Physics, Hungary, to measure the cosmic radiation dose on-board. The first on-board measurements with this system were performed by B. Farkas, the Hungarian astronaut, on the Salyut-6 space station in 1980. The same instrument was used by other crews in the following years. Doses measured at different sites in Salyut-6 are presented. The dose rates varied from 0.7 to 0.11 mGy.day -1 . After the first cosmic measurements, the system was further developed. The minimum detectable dose of the new TLD system is 1 μGy, i.e. less by one order of magnitude than that of the former system. The self-irradiation dose rate of the TLD bulbs is also reduced by more than an order of magnitude to 10 nGy.h -1 , by use of potassium-free glass for the bulb envelope. This new type of PILLE TLD system is currently on-board Salyut-7. The dose rates (0.12-0.23 mGy.day -1 ) measured in 1983 are presented in detail. (author)

  9. Thermoluminescence dating of the Kamil impact crater (Egypt)

    Science.gov (United States)

    Sighinolfi, Gian Paolo; Sibilia, Emanuela; Contini, Gabriele; Martini, Marco

    2015-02-01

    Thermoluminescence (TL) dating has been used to determine the age of the meteorite impact crater at Gebel Kamil (Egyptian Sahara). Previous studies suggested that the 45 m diameter structure was produced by a fall in recent times (less than 5000 years ago) of an iron meteorite impactor into quartz-arenites and siltstones belonging to the Lower Cretaceous Gilf Kebir Formation. The impact caused the complete fragmentation of the impactor, and the formation of a variety of impactites (e.g., partially vitrified dark and light materials) present as ejecta within the crater and in the surrounding area. After a series of tests to evaluate the TL properties of different materials including shocked intra-crater target rocks and different types of ejecta, we selected a suite of light-colored ejecta that showed evidence of strong thermal shock effects (e.g., partial vitrification and the presence of high-temperature and -pressure silica phases). The abundance of quartz in the target rocks, including the vitrified impactites, allowed TL dating to be undertaken. The variability of radioactivity of the intracrateric target rocks and the lack of direct in situ dosimetric evaluations prevented precise dating; it was, however, possible to constrain the impact in the 2000 BC-500 AD range. If, as we believe, the radioactivity measured in the fallback deposits is a reliable estimate of the mean radioactivity of the site, the narrower range 1600-400 BC (at the 2σ confidence level) can be realistically proposed.

  10. Effect of the radiation in the thermoluminescent properties of lava

    CERN Document Server

    Correcher, V; García, J

    2003-01-01

    Blue thermoluminescence (Tl) emission from different lavas of many places (Costa Rica, Canary Islands, Hawaii Islands, Iceland and Italy) corresponding to different eruptions has been studied to know its potential use in the field of dating and retrospective dosimetry. Due to the light emission is linked to the point defects of the crystalline lattice structure, X-ray diffraction analyses were performed to determine the components of this poly mineral material that mostly are cristobalite, plagioclase and phyllosilicates. Exposures to different doses (in a range of 1-25 Gy) were given to each sample to determine the evolution of the Tl signal with the irradiation under laboratory conditions. In all cases, a linear response could be observed and no saturation has been detected in this range of doses. Both natural (NTL) and induced (ITL) Tl signal exhibit a complex glow curve structure associated to a continuous trap distribution over 100 C that could be attributed to the formation-annihilation [Al0 sub 4 /alka...

  11. Quality assurance package for routine thermoluminescence dosimetry program

    International Nuclear Information System (INIS)

    Tawil, R.A.; Bencke, G.; Moscovitch, M.

    1988-01-01

    The Quality Assurance Package presented here specifies a set of reader-related hardware diagnostics and calibration procedures and automatically maintains audit trails of generated and derived thermoluminescence data. It specifies acceptable performance criteria for the reader and dosimeter assemblies; tracks and controls Readout Cycle Temperature Profiles; and ensures that the acquired data is verified. The quality of the generated glow curves is tracked by the real-time application of Computerized Glow Curve Deconvolution to reference dosimeters that may be mixed with field dosimeters during readout sessions. This package is supported by a menu-driven software system using vertical auto-selection menus, lotus-style horizontal menus, data entry menus with automatic error checking, and pop-up windows. The menu system is supported by an extensive HELP file; data EDITING is password-protected, and a journal is maintained for each editing session as part of the audit trail. Files for the Raw Data and Derived Dose results are maintained and managed in seven databases. The paper provides an in-depth analysis of each of the procedures, specifies data validation criteria, and presents samples of the reports generated

  12. Thermoluminescence dosimetry of electronic components from personal objects

    Energy Technology Data Exchange (ETDEWEB)

    Beerten, Koen [Radiation Protection Dosimetry and Calibration, Belgian Nuclear Research Centre, Boeretang 200, 2400 Mol (Belgium)], E-mail: kbeerten@sckcen.be; Woda, Clemens [Helmholtz Zentrum Muenchen - German Research Centre for Environmental Health, Institute of Radiation Protection, Ingolstaedter Landstrasse 1, D-85764 Neuherberg (Germany); Vanhavere, Filip [Radiation Protection Dosimetry and Calibration, Belgian Nuclear Research Centre, Boeretang 200, 2400 Mol (Belgium)

    2009-05-15

    Owing to the existence of ceramic materials inside common personal objects such as cellular phones and USB flash drives, these objects may be very useful in emergency (accident) dosimetry. Here we will present initial results regarding the dosimetric properties as determined by thermoluminescence (TL) from two alumina-rich electronic components from a USB flash drive. The TL method was applied in order to investigate the potential of conventional TL equipment for such purposes. For comparison, the optically stimulated luminescence (OSL) of the components was investigated as well. The studied components are ceramic resonators and alumina-based substrates from electrical resistors. The results show that various TL-related properties such as fading, optical stability and zero-dose response are different for the two investigated components. On the basis of these properties, the ceramic resonator was selected for dose recovery tests using TL and OSL. The given dose could reliably be determined using both methods, assuming that prompt measurement and/or fading correction is possible.

  13. Thermoluminescence as a dating method applied to the Morocco Neolithic

    International Nuclear Information System (INIS)

    Ousmoi, M.

    1989-09-01

    Thermoluminescence is an absolute dating method which is well adapted to the study of burnt clays and so of the prehistoric ceramics belonging to the Neolithic period. The purpose of this study is to establish a first absolute chronology of the septentrional morocco Neolithic between 3000 and 7000 years before us and some improvements of the TL dating. The first part of the thesis contains some hypothesis about the morocco Neolithic and some problems to solve. Then we study the TL dating method along with new process to ameliorate the quality of the results like the shift of quartz TL peaks or the crushing of samples. The methods which were employed using 24 samples belonging to various civilisations are: the quartz inclusion method and the fine grain technique. For the dosimetry, several methods were used: determination of the K 2 O contents, alpha counting, site dosimetry using TL dosimeters and a scintillation counter. The results which were found bring some interesting answers to the archeologic question and ameliorate the chronologic schema of the Northern morocco Neolithic: development of the old cardial Neolithic in the North, and perhaps in the center of Morocco (the region of Rabat), between 5500 and 7000 before us. Development of the recent middle Neolithic around 4000-5000 before us, with a protocampaniforme (Skhirat), little older than the campaniforme recognized in the south of Spain. Development of the bronze age around 2000-4000 before us [fr

  14. Thermoluminescence characterization of the irradiated minerals extracted from nopal

    Science.gov (United States)

    Cruz-Zaragoza, E.; Furetta, C.; Kitis, G.; Gomez, B. T.; Polymeris, G. S.; Tsirliganis, N.; Loukou, Z.

    2006-05-01

    The mineral fraction from dehydrated nopal leaves (Opuntia ficus indica ) belonging to the Cactaceae family was extracted and selected by sizes of 10 and 74 mu m and exposed to 60 Co gamma radiation at different doses in the range 70 Gy-20 kGy. The glow-curves from these polyminerals show a thermoluminescence (TL) band with one very intense peak at a temperature around 150 degrees C and a second one emerging in the high temperature region, moving in a large zone of temperature values according to the preparation used and the level of irradiation. The XRD analysis shows a composition of both biominerals as whewellite and weddellite and a mineral fraction as anorthoclase and quartz. The main TL characteristics of the polymineral content of the nopal was analyzed, i.e . the TL response at different doses and fading during storage at room temperature. The activation energy of the traps responsible for the TL emission was also investigated and a possible continuous distribution of traps is discussed. A review of the scientific literature shows that this is the first time that a TL study on nopal ionized by irradiation has been carried out.

  15. Thermoluminescent study of the hydroxyapatite irradiated with gamma radiation

    International Nuclear Information System (INIS)

    Mendoza A, D.; Hernandez A, M.; Gonzalez, P.R.; Rodriguez L, V.

    2002-01-01

    Recently in dosimetry, it has been common to use bones and teeth for detecting and measuring radiation. However it has been observed that the efficiency of detection depends on the consistency of these tissues. Since the hydroxyapatite [Ca 10 (PO 4 ) 6 (OH) 2 ] is the main mineral component of the bones and teeth, it has been suggested as material for detecting and measuring of radiations, quantifying the free radicals produced by radiation. In this work a study about the thermoluminescent properties (Tl) induced by radiation in the synthetic hydroxyapatite obtained by hydrothermal method is presented. The results have shown that this mineral presents a Tl signal whose curve contains two maximums located around 150 and 250 C degrees, respectively. Likewise, a linear behavior of the Tl signal of function of dose in the interval 10-100 Gy was observed. These results are important since that they open the possibility to use biomaterials in the dosimetric area, when they only were used for grafting in the biomedical area. (Author)

  16. About the measurements systems with pen and thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Cortes I, M.E.; Ramirez G, F.P.

    1998-01-01

    In this work it is presented dosimetric data obtained with pen and thermoluminescent dosemeters, which are used by the Occupational Exposure Personnel (OEP) of the Mexican Petroleum Institute (IMP)(1). It was marked several great characteristics as for example, the differences among units which use one and another dosemeter type. Likewise, it is given to know diverse problems that were had in the IMP at relating the data obtained with these dosemeters (which utilizes OEP) and the ICRP 60 recommendations 1990. One of the most important difficulties is to satisfy the recommended limits by ICRP, particularly those that are referring to the units and their complex calculations. With respect to the unities, the ICRP makes reference at the concepts 'dose equivalent' and 'effective dose' with the sievert unit, that the General Regulations for Radiological Safety associates with 'dose equivalent' and 'effective dose equivalent'. It was illustrated the type of dosimetric statistics which are obtained with the TLD lectures and a OEP pen dosemeter during 1997. (Author)

  17. Measurements of radon in dwellings with CR-39 track detectors

    DEFF Research Database (Denmark)

    Majborn, Benny

    1986-01-01

    A passive integrating dosemeter has been designed for measuring natural radiation in dwellings. The dosemeter contains one or two CR-39 track detectors to measure radon and three thermoluminescence dosemeters to measure external radiation. The dosemeter was investigated in a pilot study in 1983....../84, and it is now used in a nationwide survey of natural radiation in Danish dwellings. The characteristics of the dosemeter with respect to radon measurements are presented, and the radon monitoring results obtained in the pilot study are summarized...

  18. DUMAND detector

    CERN Multimedia

    This object is one of the 256 other detectors of the DUMAND (Deep Underwater Muon And Neutrino Detection) experiment. The goal of the experiment was the construction of the first deep ocean high energy neutrino detector, to be placed at 4800 m depth in the Pacific Ocean off Keahole Point on the Big Island of Hawaii. A few years ago, a European conference with Cosmic experiments was organized at CERN as they were projects like DUMAND in Hawaii. Along with the conference, a temporary exhibition was organised as well. It was a collaboration of institutions from Germany, Japan, Switzerland and the U.S.A. CERN had borrowed equipment and objects from different institutes around the world, including this detector of the DUMAND experiment. Most of the equipment were sent back to the institutes, however this detector sphere was offered to a CERN member of the personnel.

  19. Detector applications

    International Nuclear Information System (INIS)

    Pehl, R.H.

    1977-10-01

    Semiconductor detectors are now applied to a very wide range of problems. The combination of relatively low cost, excellent energy resolution, and simultaneous broad energy-spectrum analysis is uniquely suited to many applications in both basic and applied physics. Alternative techniques, such as magnetic spectrometers for charged-particle spectroscopy, while offering better energy resolution, are bulky, expensive, and usually far more difficult to use. Furthermore, they do not directly provide the broad energy-spectrum measurements easily accomplished using semiconductor detectors. Scintillation detectors, which are approximately equivalent to semiconductor detectors in convenience and cost, exhibit 10 to 100 times worse energy resolution. However, their high efficiency and large potential size recommend their use in some measurements

  20. Radiation detector

    International Nuclear Information System (INIS)

    Gillies, W.

    1980-01-01

    The radiation detector for measuring e.g. a neutron flux consists of a central emitter, an insulating shell arranged around it, and a tube-shaped collector enclosing both. The emitter itself is composed of a great number of stranded, spiral wires of small diameter giving a defined flexibility to the detector. For emitter material Pt, Rh, V, Co, Ce, Os or Ta may be used. (DG) [de

  1. Particle detectors

    CERN Multimedia

    CERN. Geneva

    2001-01-01

    The lecture series will present an overview of the basic techniques and underlying physical principles of particle detectors, applied to current and future high energy physics experiments. Illustrating examples, mainly from the field of collider experiments, will demonstrate the performance and limitations of the various techniques. After an introduction the following topics will be covered: Tracking (gas, solid state based) - Scintillation and light detection Calorimetry - Particle Identification - Electronics and Data Acquisition - Detector Systems

  2. Smoke detectors

    International Nuclear Information System (INIS)

    Bryant, J.; Howes, J.H.; Smout, D.W.S.

    1979-01-01

    A smoke detector is described which provides a smoke sensing detector and an indicating device and in which a radioactive substance is used in conjunction with two ionisation chambers. The system includes an outer electrode, a collector electrode and an inner electrode which is made of or supports the radioactive substance which, in this case, is 241 Am. The invention takes advantage of the fact that smoke particles can be allowed to enter freely the inner ionisation chamber. (U.K.)

  3. Application of a thermoluminescence method for the detection of irradiated spices.

    Science.gov (United States)

    Gastélum, S; Osuna, I; Meléndrez, R; Cruz-Zaragoza, E; Chernov, V; Calderón, T; Barboza-Flores, M

    2002-01-01

    Food irradiation is extremely effective at reducing food-borne illness as well as losses caused by infestation and contamination. Despite the well-established regulations that permit irradiation to control pathogens in spices, there are no widespread methods to detect previously irradiated food. Therefore, it has become necessary to develop new detection and dose determination methods for food subjected previously to irradiation. The present work deals with the application of the thermoluminescence (TL) phenomenon to detect irradiated spices. The process is based upon the thermoluminescence properties exhibited by the polymineral content of the irradiated specimen. After separating the organic material, it is possible to extract some polymineral substances that are suitable for thermoluminescence analysis due to interaction of the spice to ionising radiation. The method was successfully applied to examine irradiated and non-irradiated paprika of Mexican origin. The spice was irradiated with gamma rays at doses of 5, 10 and 15 kGy. The separated thermoluminescent polymineral was found to be composed mainly of quartz and feldspar. The thermoluminescence glow curve of the irradiated specimen shows a wide band peaked 228, 268 and 336 degrees C, resembling closely the combined TL of quartz and feldspars. The method allows for the determination of the retrospective dose exposure.

  4. Thermoluminescence of magnesium doped zirconium oxide (ZrO2:Mg) UV irradiated

    International Nuclear Information System (INIS)

    Rivera Montalvo, Teodoro; Furetta, Claudio

    2008-01-01

    Full text: The monitoring of ultraviolet radiation (UVR) different thermoluminescent (TL) materials have been used to measure UVR. UV dosimetry using thermoluminescence phenomena has been suggested in the past by several authors. This technique has an advantage over others methods due to the readout of the samples. Other advantages of these phosphors are their small size, portability, lack of any power requirements, linear response to increasing radiation dose and high sensitivity. Zirconium oxide, recently received full attention in view of their possible use as thermoluminescent dosimeter (TLD), if doped with suitable activators, in radiation dosimetry. In the present investigation thermoluminescent (TL) properties of magnesium doped zirconium oxide (ZrO 2 :Mg) under ultraviolet radiation (UVR) were studied. The ZrO 2 :Mg powder of size 30-40 nm, having mono clinical structure, exhibit a thermoluminescent glow curve with one peak centered at 180 C degrees. The TL response of ZrO 2 :Mg as a function ultraviolet radiation exhibits four maxima centered at 230, 260, 310 and 350 nmn. TL response of ZrO 2 :Mg as a function of spectral irradiance of UV Light was linear in a wide range. Fading and reusability of the phosphor were also studied. The results showed that ZrO 2 :Mg nano powder has the potential to be used as a UV dosemeter in UVR dosimetry. (author)

  5. Development of a multichannel dosimeter for radiotherapy; Desenvolvimento de um dosimetro multicanal para radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Menezes, Claudio Jose Mesquita

    2000-06-01

    In radiotherapy, verification of the patient dose is of great important for the success of the treatment. Uncertainties in the evaluation of this dose can produce serious complications such as the loss of the control of the disease and damage to normal tissue. Semiconductor detectors present advantages over other types of radiation detectors such as ionization chambers and thermoluminescent dosimeters including small dimensions, high sensitivity and fast response. In this work, a multichannel dosimetric system is linear with dose, for a 6 MV x-ray beam and also with a beam of cobalt-60 gamma rays. The coefficients of determination of the calibration curves were better then 0,9998 in all cases. The four sensors presented similar response with the dose for different field sizes. The variation of the response was smaller than 1%. In a related study, depth dose was measured, and the results showed a good agreement compared to theoretical values. The angular response of the detectors showed a variation of 7% for angles of 45 deg C. Using the Anderson Random phantom, dose at the isocenter was determined from measurements of the surface dose. From the results obtained it can be concluded that the dosimetric system developed is adequate for the evaluation of many parameters in radiation fields used in radiotherapy. This system can be used to measure the patient entrance dose under treatment conditions, and the equipment can be used in the radiotherapy quality assurance program. (author)

  6. Photon detectors

    International Nuclear Information System (INIS)

    Va'vra, J.

    1995-10-01

    J. Seguinot and T. Ypsilantis have recently described the theory and history of Ring Imaging Cherenkov (RICH) detectors. In this paper, I will expand on these excellent review papers, by covering the various photon detector designs in greater detail, and by including discussion of mistakes made, and detector problems encountered, along the way. Photon detectors are among the most difficult devices used in physics experiments, because they must achieve high efficiency for photon transport and for the detection of single photo-electrons. For gaseous devices, this requires the correct choice of gas gain in order to prevent breakdown and wire aging, together with the use of low noise electronics having the maximum possible amplification. In addition, the detector must be constructed of materials which resist corrosion due to photosensitive materials such as, the detector enclosure must be tightly sealed in order to prevent oxygen leaks, etc. The most critical step is the selection of the photocathode material. Typically, a choice must be made between a solid (CsI) or gaseous photocathode (TMAE, TEA). A conservative approach favors a gaseous photocathode, since it is continuously being replaced by flushing, and permits the photon detectors to be easily serviced (the air sensitive photocathode can be removed at any time). In addition, it can be argued that we now know how to handle TMAE, which, as is generally accepted, is the best photocathode material available as far as quantum efficiency is concerned. However, it is a very fragile molecule, and therefore its use may result in relatively fast wire aging. A possible alternative is TEA, which, in the early days, was rejected because it requires expensive CaF 2 windows, which could be contaminated easily in the region of 8.3 eV and thus lose their UV transmission

  7. In-vivo dosimetry in radiotherapy: a comparison of the response of semiconductor and thermoluminescence (TLD700) dosemeters

    Energy Technology Data Exchange (ETDEWEB)

    Vynckier, S. [Universite Catholique de Louvain, Brussels (Belgium). Cliniques Universitaires St. Luc; Greffe, J.L.; Loncol, T.; Vanneste, F.; Octave-Prignot, M.; Denis, J.M.; De Patoul, N.

    1995-12-01

    Semiconductor dosemeters and thermoluminescence dosemeters were calibrated in view of in-vivo dosimetry. Their response in a 8 MV photon beam and the respective correction factors for the treatment conditions were systematically studied. A total of 249 entrance and exit measurements with this dual detector combination were performed, mainly for treatments of the head and neck region. The resulting entrance and exit doses were compared with the expected doses at these positions, calculated on basis of the treatment and patient parameters. The results at the entrance showed a value of 1.010 (2.8% for the ratio of the measured to the calculated dose by diodes, 1.013) 4.9% for the ratio of the measured to the calculated dose by TLD and 1.003 (3.6% for the ratio of the measured dose by TLD to diodes. With respect the exit dose, the results were 0.998) 4.9%, 1.016 (7.7% and 1.019) 7.0% respectively after correction for the heterogeneity`s. Although the standard deviation for the TLD dosemeters is systematically larger than the standard deviation for the diodes, it is concluded that both dosemeters will yield similar results for-in-vivo dosimetry, if utilized under the same conditions.

  8. Thermoluminescent dosimetry of new phosphors of Zn O exposed to beta radiation

    International Nuclear Information System (INIS)

    Cruz V, C.; Burruel I, S.E.; Grijalva M, H.; Barboza F, M.; Bernal, R.

    2004-01-01

    In this work, we report the thermoluminescence dosimetry of a new Zn O phosphor obtained by annealing of Zn S powder precipitated when Zn S films were grown by employing a CBD method. The collected Zn S powder was pressed in a die to form pellets which were subjected to different thermal treatments under air atmosphere. X-ray diffraction (XRD) patterns and energy-dispersive X-ray Spectrometry (EDS) analyses confirmed the transformation of Zn S to Zn O. The phosphors thus obtained were exposed to high doses of beta radiation and their thermoluminescent dosimetry show that these new phosphors are materials suitable to be used in high dose thermoluminescence dosimetry. (Author)

  9. Thermoluminescence and cathodoluminescence studies of calcite and MgO: surface defects and heat treatment

    International Nuclear Information System (INIS)

    Goeksu, H.Y.; Brown, L.M.

    1988-01-01

    Some of the problems which preclude accurate thermoluminescence (TL) dating of geologically formed calcite stem from different sample pre-treatment procedures, such as grinding, drilling or pre-heating. It has long been known that grinding can introduce spurious TL in calcite, but there have been wide differences of opinion as to the magnitude of the influence and its importance. Therefore, various grinding and acid-washing procedures have been suggested to avoid spurious thermoluminescence. Various models have been developed to explain the mechanism. We have studied the changes in thermoluminescence (TL) and cathodoluminescence (CL) properties as well as in the spectral composition of the glow from calcite and MgO due to surface defects and heat treatment. It is found that both laboratory heat treatment and surface indents give rise to changes in TL efficiency. (author)

  10. Thermoluminescent analysis of amorphous and crystalline SiO{sub 2} exposed to gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Villa S, G.; Mendoza A, D.; Gonzalez, P.R.; Espinosa P, M.E. [ININ, 52750 Ocoyoacac, EStado de Mexico (Mexico)

    2006-07-01

    Silicon oxide (SiO{sub 2}) has been used in electroluminescence and thermoluminescence (TL) devices. However, its emission mechanism have not been yet clearly explained. The crystalline and amorphous SiO{sub 2} luminescent analyses are important to compare their behaviour in order to understand the emission mechanism. For this reason, the present work has the goal to show and compare the thermoluminescent analysis of obsidian and quartz: amorphous and crystalline SiO{sub 2}, respectively. According to the results, quartz shows two TL peaks located at 145 and 215 C, while obsidian shows three TL peaks at 125, 195 and 298 C. Moreover, TL intensity was higher for quartz than obsidian samples. Nonetheless, both signals shown a linear correlation in the interval of radiation dose from 50 to 400 Gy. These facts suggest that the atomic array plays a very important role in the thermoluminescent behaviour of the SiO{sub 2} materials. (Author)

  11. Thermoluminescence of thin films deposited by laser ablation; Termoluminiscencia de peliculas delgadas depositadas por ablacion laser

    Energy Technology Data Exchange (ETDEWEB)

    Escobar A, L.; Camps, E.; Arrieta, A.; Romero, S.; Gonzalez, P.R.; Olea M, O.; Diaz E, R. [Depto. de Fisica, ININ, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2003-07-01

    Materials in thin film form have received great attention in the last few years mainly because of their singular properties, which may differ significantly from their bulk attributes making them attractive for a wide variety of applications. In particular, thermoluminescence (Tl) properties of thin films have been studied recently owing to their potential applications in detection for both ionizing and non ionizing radiation. The aim of the present work is to report the synthesis and characterization of C Nx, aluminum oxide and titanium oxide thin films. Thermoluminescence response of the obtained thin films was studied after subject thin films to UV radiation (254 nm) as well as to gamma radiation (Co-60). Thermoluminescence glow curves exhibited a peak centered at 150 C for CN{sub x} whereas for titanium oxide the glow curve shows a maximum peaking at 171 C. Characterization of the physical properties of the deposited materials is presented. (Author)

  12. Preparation and structural characterization of the thermoluminescent material CaSO4: Dy

    International Nuclear Information System (INIS)

    Sanchez R, A.; Azorin, J.; Gonzalez M, P.R.; Rivera, T.

    2005-01-01

    The grade of crystallinity of a material is important so that the one is presented the thermoluminescence phenomenon; for what is necessary to study those structural characteristic of a TL material and to correlate them with its TL response when being irradiated with ionizing radiation. The calcium sulfate activated with Dysprosium (CaSO 4 : Dy) it is a material that has demonstrated its efficiency in the dosimetry of the ionizing radiation for the thermoluminescence method. In this work the structural characterization of this prepared material for the recrystallization method by means of the evaporation of the solvent and their relationship with their TL response is presented. The results showed that the best material to be used in thermoluminescent dosimetry presents a crystalline structure in orthorhombic phase and a particle size in the interval of 80 μm to 200 μm. (Author)

  13. Dating of pre hispanic ceramics from the archaeological zone of Zoque by thermoluminescence method

    International Nuclear Information System (INIS)

    Valdes, J.V.; Gonzalez, P.R.; Mendoza, D.; Tenorio, D.; Terreros, E.; Ramirez, A.

    2007-01-01

    Full text: The dating of pre hispanic ceramics resides permitting us to located them in a certain period of the history; allows us to verify it origin. The thermoluminescence is a technique that permits us to estimate the absolute age of the archaeological samples. The present work is directed in determining the age by the method of thermoluminescence of archaeological samples of the grotto of Concubac, located in the Serrana Region of Tabasco. To determine the mineralogical composition of the samples, analysis of diffraction of X rays and Energy Dispersive X-ray Spectroscopy (EDS) have been conducted. The radiation emitted by the ground where the samples were buried and the contribution of the cosmic radiation was measured with thermoluminescent dosimeters of LiF:Mg,Cu,P+PTFE. The feasibility of dating of the studied samples is broadly disputed in function of the contents of minerals, as well as the procedure and management of the sample. (Author)

  14. The thermoluminescence as tool in the reconstruction of volcanic events

    International Nuclear Information System (INIS)

    Ramirez L, A.; Schaaf, P.; Martin del Pozzo, A.L.; Gonzalez M, P.

    2000-01-01

    Within the Mexican land a great number of volcanoes are situated which a considerable part of them are still active. The relevance of dating pomex deposits, ash or lava of these poly genetic volcanoes is to determine the periodicity and magnitude of the volcanic events happened. In this work is presented the preliminary result of the dating by thermoluminescence in a pomex of a pyroclastic flux coming from a volcano in the state of Puebla with the purpose of providing elements to the knowledge which describe the eruptive history of the explosive volcanism at center of Mexico. For the sample dating the volcanic glasses of pomex were separated and it was applied the fine grain technique with a grain size between 4-11 μ m. In order to calculate the rate of annual dose it was carried out the following: in the determination of 238 U and 232 Th radioisotope concentration was used the neutron activation technique in a nuclear reactor, in the determination of the K 40 radioisotope was used a scanning electron microscope, the rate of environmental and cosmic dose was measured arranging Tl dosemeters of CaSO 4 : Dy in the sampling place. In order to calculate the paleodoses it was carried out the following: the equivalent dose (Q) was determined starting form the additive method and the supra linearity factor (I) starting from regenerative method and in both methods the irradiated process was realized with a 90 Sr beta source. With the above determinations it was calculated a paleodoses of 231 Gy and a rate of annual dose of 6.074 x 10 -3 Gy/year, estimating an age of: Age pomez = 231 Gy / 6.074 Gy x 10 -3 Gy /year = 38030 ± 4000 years. (Author)

  15. Thermoluminescence of cerium and terbium -doped calcium pyrophosphate

    Energy Technology Data Exchange (ETDEWEB)

    Roman L, J.; Cruz Z, E. [UNAM, Instituto de Ciencias Nucleares, Circuito Exterior, Ciudad Universitaria, 04510 Mexico D. F. (Mexico); Lozano R, I. B.; Diaz G, J. A. I., E-mail: jesus.roman@nucleares.unam.mx [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Av. Legaria No. 694, 11500 Mexico D. F. (Mexico)

    2015-10-15

    The aim of this work is to report the thermoluminescence (Tl) response of Calcium Pyrophosphate phosphor doped with Cerium and Terbium impurities (Ca{sub 2}P{sub 2}O{sub 7}:Ce{sup 3+},Tb{sup 3+}). The phosphors were synthesized using the co-precipitation method and annealed at 900 degrees C by two hours for obtain the β phase. The intentional doping with Ce and Tb ions was 1 at.% and 0.1 at.%, whereas in the EDS results the concentration of impurities was 0.39 at.% and 0.05 at.%, respectively. The superficial morphology of phosphor is mainly composed by thin wafers of different size. All samples were exposed to gamma rays from {sup 60}Co in the Gammacell-200 irradiator. The Tl response of the phosphor was measured from Rt up to 350 degrees C and under nitrogen atmosphere in a Harshaw TLD 3500 reader. The glow curves of the Ca{sub 2}P{sub 2}O{sub 7}:Ce{sup 3+},Tb{sup 3+} powders showed a broad intense Tl peak centered at 165 degrees C and a shoulder at approximate 260 degrees C was observed. A linear Tl response in the range of absorbed dose of 0.2 to 10 Gy was obtained. Tl glow curves were analyzed using the initial rise (IR)and computerized glow curve deconvolution methods to evaluate the kinetics parameters such as activation energy (E), frequency factor (s) and kinetic order (b). (Author)

  16. 128 slice computed tomography dose profile measurement using thermoluminescent dosimeter

    International Nuclear Information System (INIS)

    Salehhon, N; Hashim, S; Karim, M K A; Ang, W C; Musa, Y; Bahruddin, N A

    2017-01-01

    The increasing use of computed tomography (CT) in clinical practice marks the needs to understand the dose descriptor and dose profile. The purposes of the current study were to determine the CT dose index free-in-air (CTDI air ) in 128 slice CT scanner and to evaluate the single scan dose profile (SSDP). Thermoluminescent dosimeters (TLD-100) were used to measure the dose profile of the scanner. There were three sets of CT protocols where the tube potential (kV) setting was manipulated for each protocol while the rest of parameters were kept constant. These protocols were based from routine CT abdominal examinations for male adult abdomen. It was found that the increase of kV settings made the values of CTDI air increased as well. When the kV setting was changed from 80 kV to 120 kV and from 120 kV to 140 kV, the CTDI air values were increased as much as 147.9% and 53.9% respectively. The highest kV setting (140 kV) led to the highest CTDI air value (13.585 mGy). The p -value of less than 0.05 indicated that the results were statistically different. The SSDP showed that when the kV settings were varied, the peak sharpness and height of Gaussian function profiles were affected. The full width at half maximum (FWHM) of dose profiles for all protocols were coincided with the nominal beam width set for the measurements. The findings of the study revealed much information on the characterization and performance of 128 slice CT scanner. (paper)

  17. Thermoluminescence dating of potteries excavated at Bhagwanpura and Mathura

    International Nuclear Information System (INIS)

    Nambi, K.S.V.; Sasidharan, R.; Soman, S.D.

    1979-01-01

    Thermoluminescence (TL) dating attempts were made on sherds of freshly excavated potteries from Bhagwanpura and Mathura sites. TL measurements were generally made from the fine grains of the potsherds; attempts were also made to separate the quartz inclusions from some of the potsherds and evaluate the TL. Dose-rate estimations were made from an analysis of natural radioactivity of the samples; TLD estimation of the environmental gamma dose-rate component was also attempted for the Mathura sites. The TL age estimates ranged between 2000 and 5000 years, B.P. for the Bhagwanpura series and between 1400 and 3000 years, B.P. for the Mathura series. Distinctly different trends were seen in the ages of graywares and redwares from Bhagwanpura: with increasing depth at the site, the grayware ages diminished (upto 1.3 depth beyond which they do not occur) while the redware ages remain the same upto 1.3 m depth and increase regularly beyond. In the case of eight Mathura potsherds for which the archaeologists' expected age values were available, a good to fair (+- 2 to +- 19%) agreement with the TL ages could be seen for four sherds. The estimated accuracies of the TL ages range between +- 9 to +- 19% and such a high value stems from the generous allowance made for all possible values of water content in pottery and soil over the archaeological period; if reasonable values for the actual degree of wetness could be provided, the TL ages can be estimated with accuracies of the order of +- 5%. (auth.)

  18. Thermoluminescent dosimetry in dentistry students in radiological training

    International Nuclear Information System (INIS)

    Loya, M.; Duarte, R.; Montero, M.E.; Gonzalez, P.R.; Ojeda, S.L.; Sanin, L.H.

    2007-01-01

    Full text: In this work, the obtained results of the mensuration of the equivalent one are presented of dose (E), in students of the career of Dentistry who during their training in radiology complete the three lists of patient, odontologist and observer. The study one carries out with 35 students (Odontologists), 7 men and 28 women, with ages between 20 and 24 years. A characterization of risk was made following the methodology of the Agency for the environmental control of United States (EPA), counting the number of shots in each list, during the time of training. The effective energy of the X rays used was of 24 KeV. The irradiation technique understood two modalities; the first one with 3 shots of 1.25 seconds and the second with 5 shots of 0.6 seconds. The measurement of E, was carried out with thermoluminescent dosemeters (TL) of LiF:Mg,Cu,P+PTFE, developed in the National Institute of Nuclear Research (ININ). The homogenization of the dosemeters showed a variation in its response to the radiation of 1.85%DS. For the odontologist position, the dosemeters was placed to the height of the chest and the measurement was multiplied by the number of shots that it was 304. The E value was of 3.62 mSv/four-month (11 mSv/year), without any safety equipment and of 2.02 mSv/four-month (6.14 mSv/year), when was considered the scenario for this position with use of vest and lead collar, like safety equipment, diminishing E, almost 50%. In the case of the corresponding position to patient, E, it was measured in different organs of interest, the obtained results are compared with the international standards. Recommendations are given for similar cases. (Author)

  19. Thermoluminescent analyses of mean photon energy of a field

    Energy Technology Data Exchange (ETDEWEB)

    Cavalieri, T. A.; De Paiva, F.; Fonseca, G.; Dalledone S, P. de T.; Yoriyaz, H., E-mail: tassio.cavalieri@usp.br [Instituto de Pesquisas Energeticas e Nucleares / CNEN, Av. Lineu Prestes 2242, Cidade Universitaria, 05508-000 Sao Paulo (Brazil)

    2014-08-15

    Nowadays a common method of dosimetry is utilize the thermoluminescent dosimetry (TLD) of LiF, where for pure gamma field is typically used the LiF or CaF{sub 2} TLDs and for mixed neutron and gamma field dosimetry is used the pair TLD-600/TLD-700. The difference between these three LiF TLDs is the amount of isotope {sup 6}Li in their composition. The isotope {sup 6}Li has a great cross section for thermal neutrons, making the TLD-600 sensitive to thermal neutrons beyond the radiation gamma. Whereas the TLD-700 is considered sensitive only for radiation gamma. Some studies showed an energetic dependence of these TLDs for gammas rays. So the goal of this work was study these energetic dependence of TLDs from the angular coefficient of their response versus dose calibration curves when they were irradiated in four fields with photons of different energies: 43 keV, 662 keV, 1.2 MeV, 3 MeV. In order to create the calibration curves TLD, it was performed three irradiations with distinct exposure times for each photon energy. These studies showed a different angular coefficient to each curve; demonstrate the energetic dependence of these TLDs. By simulation with Monte Carlo based code, MCNP-5, it was observed the deposited photon dose due to different photons energies. From these simulations, it was also possible to observe a difference of dose deposition in TLDs when they were exposed to the same dose provided from different photons energies. These work showed the previously study of photon energetic dependence of LiF TLDs. (Author)

  20. Gamma-ray dosimetry errors with thermoluminescent dose meters

    International Nuclear Information System (INIS)

    Graham, C.L.; Homann, S.G.

    1978-01-01

    Gamma-ray dosimetry errors can occur when thermoluminescence dose meters (TLDs) are irradiated in thin-walled containers. An over-response has been observed for LiF TLDs, irradiated by an isotropic source, of approximately 25% for 24 Na; 20% for 60 Co, and 2% for 137 Cs. The over-response for CaF 2 TLDs was found to be less than the over-response of LiF TLDs. Under-response errors can occur for TLDs in thin-walled containers irradiated under narrow-beam geometry conditions because electron equilibrium is not established, but this error is well known and is not discussed in this paper. The observed over-response is attributable to electrons originating in the radiation source holder and the surrounding air that are scattered into the TLD material. This over-response is less pronounced for 137 Cs gamma rays because few scattered electrons have sufficient energy to penetrate the TLD; however, for higher energy gamma rays, more electrons can panetrate the TLD, resulting in a greater dose. This effect will also be observed with any dose meter that has a small sensitive volume surrounded by a thin wall. The over-response of a dosimetry film in its paper wrapping was measured to be approximately 25% for 60 Co gamma rays and 3% for 137 Cs gamma rays, although this would rarely introduce an error since film dose meters are usually irradiated in a thick-walled badge. This paper presents the measured over-responses of various TLD chips for several exposure conditions and experimental results which demonstrate the cause of the over-response. (author)

  1. Effect of phase transitions on thermoluminescence characteristics of nanocrystalline alumina

    International Nuclear Information System (INIS)

    Rani, Geeta; Sahare, P.D.

    2013-01-01

    Highlights: •Synthesis of Al 2 O 3 nanocrystalline TLD phosphor. •Material characterizations by XRD, TEM and TL. •Change in structure and morphology of the phase transition alumina. •Change in glow curve structures and trapping parameters on phase transitions. -- Abstract: Nanocrystalline boehmite (γ-AlOOH) was synthesized by hydrothermal method using AlCl 3 ·6H 2 O and Urea as precursors. The material gets decomposed to form the γ-Al 2 O 3 phase at around 873 K on annealing in air. On annealing further at higher temperatures it gets converted into different phases, such as, δ, θ and the most stable α-phase. Not only the phase changes but the annealing has also changed the morphology of the nanomaterial, i.e. it has changed from spindle like edges to vermicular structures and also grew bigger in sizes. The formations of different phases were confirmed by the X-ray diffraction (XRD) patterns and the changes in the morphology were seen through the TEM images. Further the effect of different phases on the thermoluminescence (TL) glow curve structures was studied and it is also shown that the TL glow curves structures do change due to phase transformations. To investigate further and to determine trapping parameters, different glow curves have been theoretically deconvoluted using computerized glow curve deconvolution (CGCD method) into simple glow peaks. The values of different trapping parameters also change as the glow curve structures on phase transformations due to reorganization of energy levels and the stress/strain generated by some intermediate phases

  2. CONHECIMENTO: UM FATOR DE DESENVOLVIMENTO ORGANIZACIONAL

    Directory of Open Access Journals (Sweden)

    Adilson dos Santos Morais

    2017-09-01

    Full Text Available Cada vez mais, criar conhecimento útil para atuar em uma posição de vantagem competitiva, orientado para o desenvolvimento organizacional e valorizando o capital humano tem-se demonstrato uma estratégia eficaz. O presente artigo busca apresentar a importância do conhecimento para o desenvolvimento das organizações em âmbito geral com destaque para as comunidades de prática. Esse conhecimento é derivado das interações desenvolvidas em processos de aprendizagem que ocorrem no ambiente organizacional. Para este, realizou-se um estudo teórico, descritivo, que tem como procedimento a pesquisa bibliográfica. Deste modo, apresenta como resultado deste trabalho a evidência de que existem poucos resultados divulgados sobre retorno financeiro e os benefícios dos investimentos realizados no capital intelectual humano pelas organizações. Porém, o conhecimento agrega valor à organização aumentando o valor do capital intelectual e as literaturas sobre o conhecimento e desenvolvimento organizacional consideram o capital intelectual o fator chave para a melhoria nos sistemas estratégicos. Destaca-se que esta contribuição poderá instigar cada vez mais a criação de conhecimento como fator de reconhecimento humano e de desenvolvimento das organizações.

  3. Thermoluminescent response of LaAlO{sub 3}:Pr; Respuesta termoluminiscente de LaAlO{sub 3}:Pr

    Energy Technology Data Exchange (ETDEWEB)

    Morales H, A.; Zarate M, J. [Universidad Michoacana de San Nicolas de Hidalgo, Instituto de Investigacion en Metalurgia y Materiales, Ciudad Universitaria, Edif. U, 58060 Morelia, Michoacan (Mexico); Azorin N, J. [Universidad Autonoma Metropolitana, Unidad Iztapalapa, Av. San Rafael Atlixco 186, Col. Vicentina, 09340 Mexico D. F. (Mexico); Rivera M, T., E-mail: feyo_yo@hotmail.com [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Av. Legaria 694, 11500 Mexico D. F. (Mexico)

    2015-10-15

    In this study, the thermoluminescence response of doped lanthanum aluminate (LaAlO{sub 3}) with praseodymium ion (Pr) obtained by the Pechini method and drying by the spraying technique Spry Dryer was studied. The obtained powders were analyzed structurally by the X-ray diffraction technique; the morphological characterization was by the scanning electron microscopy technique. The obtained powders at 800 degrees C presented crystallinity and showed a Rhombohedral crystal structure, this phase was observed by X-ray diffraction patterns. Thermoluminescence response of LaAlO{sub 3}:Pr showed a brightness curve with a peak centered at 157 degrees C. The sensitivity of the doped samples was improved about 90 times in comparison with the undoped sample. Thermoluminescence response in function of the wavelength showed a maximum at 230 nm, reproducibility of thermoluminescence response was ±50%. Also the fading in thermoluminescence response was studied. (Author)

  4. Shaped detector

    International Nuclear Information System (INIS)

    Carlson, R.W.

    1981-01-01

    A radiation detector or detector array which has a non-constant spatial response, is disclosed individually and in combination with a tomographic scanner. The detector has a first dimension which is oriented parallel to the plane of the scan circle in the scanner. Along the first dimension, the detector is most responsive to radiation received along a centered segment of the dimension and less responsive to radiation received along edge segments. This non-constant spatial response can be achieved in a detector comprised of a scintillation crystal and a photoelectric transducer. The scintillation crystal in one embodiment is composed of three crystals arranged in layers, with the center crystal having the greatest light conversion efficiency. In another embodiment, the crystal is covered with a reflective substance around the center segment and a less reflective substance around the remainder. In another embodiment, an optical coupling which transmits light from adjacent the center segment with the greatest intensity couples the scintillation crystal and the photoelectric transducer. In yet another embodiment, the photoelectric transducer comprises three photodiodes, one receiving light produced adjacent the central segment and the other two receiving light produced adjacent the edge segments. The outputs of the three photodiodes are combined with a differential amplifier

  5. Detection and thermoluminescence of coriander (Coriandrum sativum L.) irradiated with 60Co

    International Nuclear Information System (INIS)

    Ruiz G, B.; Cruz Z, E.; Barboza F, M.

    2009-10-01

    The fresh and dried coriander (Coriandrum sativum L.) is a spice of high commercial value as food for consumption in Mexico. Their hygienic quality is often poor due to some factors: contaminants present in irrigation water and the cultivation atmosphere, harvesting and post harvest handling, mainly. The process by radiation is an alternative to achieve the sterilization to adequate dose for the hygienic quality for its consumption. However, irradiation also involves food detection exposed to radiation. This paper presents detected results on the dried coriander that was obtained from fresh samples and thermoluminescent properties such as glow curves structure from low doses (0.5 Gy) to high (15 kGy), the dose response, thermoluminescent signal decay, in order to determine the loss of stability during the storage of the poly mineral fraction. We obtained the inorganic fraction separation of the organic part of particle sizes of 10 μm by the Zimmerman method. The samples were exposed at two dose ranges; 0.5-400 Gy and 0.5-15 kGy of gamma radiation with 60 Co. The limit of thermoluminescent detection of the irradiated coriander samples was from 1 Gy. The glow curves were at a broad band of 35-400 C, with a maximum thermoluminescence around 182-196 C, and run at 164 C for high doses of 15 kGy. The range of linear response to dose was 4-25 Gy, whereas higher doses than the kGy order the response increase with the dose. The thermoluminescent properties of the coriander poly mineral fraction, show it can be used to identify irradiated food at gamma doses relatively low and even in doses of commercial interest due to the high stability of thermoluminescent signals. (Author)

  6. Track etch and thermo luminescent detectors response to high energy charged particles

    Czech Academy of Sciences Publication Activity Database

    Spurný, František; Jadrníčková, Iva

    2008-01-01

    Roč. 43, Supp. 1 (2008), S169-S173 ISSN 1350-4487. [International Conference on Solids /23./. Beijing, 11.09.2006-15.09.2006] R&D Projects: GA ČR GA202/04/0795 Grant - others:Evropské společenství(XE) ILSRA - 2004 - 248 Institutional research plan: CEZ:AV0Z10480505 Keywords : track etch detector * thermoluminescent detectors * LET spectrometry Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.267, year: 2008

  7. Determination of the dose rapidity of a 90 Sr beta radiation source using thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Gonzalez M, P.R.; Azorin N, J.; Rivera M, T.

    2000-01-01

    The thermoluminescent dosemeters developed in Mexico, have been used efficiently in environmental and personal dosimetry. When the dose rate of some source is not known can be estimated with the use of thermoluminescent dosemeters taking in account the geometrical array used in the irradiations for reproducibility of the results in posterior irradiations. In this work it was estimated the dose rate of a 90 Sr- 90 Y beta radiation source which is property of the Nuclear Sciences Institute, UNAM, therefore it was l ended to the Metropolitan Autonomous University- Iztapalapa Unit for the characterization of new Tl materials, taking account of the institutional collaboration agreements. (Author)

  8. Thermoluminescence characteristics of different dimensions of Ge-doped optical fibers in radiation dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Begum, M.; Mizanur R, A. K. M.; Abdul R, H. A.; Yusoff, Z. [Multimedia University, Faculty of Engineering, 63100 Cyberjaya, Selangor Darul Ehsan (Malaysia); Begum, M. [Bangladesh Atomic Energy Commission, E-12/A, Agargaon, Sher-e-Blanga Nagar Dhaka-1207 (Bangladesh); Mat-Sharif, K. A. [Lingkaran Teknokrat Timur, Telekom Research and Development, 63000 Cyberjaya, Selangor Darul Ehsan (Malaysia); Amin, Y. M. [University of Malaya, Faculty of Science, Depatment of Physics, 50603 Kuala Lumpur (Malaysia); Bradley, D. A., E-mail: go2munmun@yahoo.com [University of Surrey, Department of Physics, Guildford GU2 7XH (United Kingdom)

    2014-08-15

    Important thermoluminescence (Tl) properties of five (5) different core sizes Ge doped optical fibers have been studied to develop new Tl material with better response. These are drawn from same preform applying different speed and tension during drawing phase. The results of the investigations are also compared with most commonly used standard TLD-100 chips (LiF:Mg,Ti) and commercial multimode Ge doped optical fiber (Yangtze Optical Fiber, China). Scanning Electron Microscope (Sem) and EDX analysis of the fibers are also performed to map Ge distribution across the deposited region. Standard Gamma radiation source in SSDL (Secondary Standard Dosimetry Lab) was used for irradiation covering dose range from 1 Gy to 10 Gy. The essential dosimetric parameters that have been studied are Tl linearity, reproducibility and fading. Prior to irradiation all samples ∼0.5 cm length are annealed at temperature of 400 grades C for 1 hour period to standardize their sensitivities and background. Standard TLD-100 chips are also annealed for 1 hour at 400 grades C and subsequently 2 hours at 100 grades C to yield the highest sensitivity. Tl responses of these fibers show linearity over a wide gamma radiation dose that is an important property for radiation dosimetry. Among all fibers used in this study, 100 μm core diameter fiber provides highest response that is 2.6 times than that of smallest core (20 μm core) optical fiber. These fiber-samples demonstrate better response than commercial multi-mode optical fiber and also provide low degree of fading about 20% over a period of fifteen days for gamma radiation. Effective atomic number (Z{sub eff}) is found in the range (13.25 to 13.69) that is higher than soft tissue (7.5) however within the range of human-bone (11.6-13.8). All the fibers can also be re-used several times as a detector after annealing. Tl properties of the Ge-doped optical fibers indicate promising applications in ionizing radiation dosimetry. (author)

  9. Thermoluminescence characteristics of different dimensions of Ge-doped optical fibers in radiation dosimetry

    International Nuclear Information System (INIS)

    Begum, M.; Mizanur R, A. K. M.; Abdul R, H. A.; Yusoff, Z.; Begum, M.; Mat-Sharif, K. A.; Amin, Y. M.; Bradley, D. A.

    2014-08-01

    Important thermoluminescence (Tl) properties of five (5) different core sizes Ge doped optical fibers have been studied to develop new Tl material with better response. These are drawn from same preform applying different speed and tension during drawing phase. The results of the investigations are also compared with most commonly used standard TLD-100 chips (LiF:Mg,Ti) and commercial multimode Ge doped optical fiber (Yangtze Optical Fiber, China). Scanning Electron Microscope (Sem) and EDX analysis of the fibers are also performed to map Ge distribution across the deposited region. Standard Gamma radiation source in SSDL (Secondary Standard Dosimetry Lab) was used for irradiation covering dose range from 1 Gy to 10 Gy. The essential dosimetric parameters that have been studied are Tl linearity, reproducibility and fading. Prior to irradiation all samples ∼0.5 cm length are annealed at temperature of 400 grades C for 1 hour period to standardize their sensitivities and background. Standard TLD-100 chips are also annealed for 1 hour at 400 grades C and subsequently 2 hours at 100 grades C to yield the highest sensitivity. Tl responses of these fibers show linearity over a wide gamma radiation dose that is an important property for radiation dosimetry. Among all fibers used in this study, 100 μm core diameter fiber provides highest response that is 2.6 times than that of smallest core (20 μm core) optical fiber. These fiber-samples demonstrate better response than commercial multi-mode optical fiber and also provide low degree of fading about 20% over a period of fifteen days for gamma radiation. Effective atomic number (Z eff ) is found in the range (13.25 to 13.69) that is higher than soft tissue (7.5) however within the range of human-bone (11.6-13.8). All the fibers can also be re-used several times as a detector after annealing. Tl properties of the Ge-doped optical fibers indicate promising applications in ionizing radiation dosimetry. (author)

  10. Thermoluminescence characteristics of Ge-doped optical fibers with different dimensions for radiation dosimetry

    International Nuclear Information System (INIS)

    Begum, Mahfuza; Rahman, A.K.M. Mizanur; Abdul-Rashid, H.A.; Yusoff, Z.; Begum, Mahbuba; Mat-Sharif, K.A.; Amin, Y.M.; Bradley, D.A.

    2015-01-01

    Important thermoluminescence (TL) properties of five (5) different core sizes Ge-doped optical fibers have been studied to develop new TL material with better response. These are drawn from same preform applying different speed and tension during drawing phase to produce Ge-doped optical fibers with five (5) different core sizes. The results of the investigations are also compared with most commonly used standard TLD-100 chips (LiF:Mg,Ti) and commercial multimode Ge-doped optical fiber (Yangtze Optical Fiber, China). Scanning Electron Microscope (SEM) and EDX analysis of the fibers are also performed to map Ge distribution across the deposited region. Standard Gamma radiation source in Secondary Standard Dosimetry Lab (SSDL) was used for irradiation covering dose range from 1 Gy to 10 Gy. The essential dosimetric parameters that have been studied are TL linearity, reproducibility and fading. Prior to irradiation all samples ∼0.5 cm length are annealed at temperature of 400 °C for 1 h period to standardize their sensitivities and background. Standard TLD-100 chips are also annealed for 1 h at 400 °C and subsequently 2 h at 100 °C to yield the highest sensitivity. TL responses of these fibers show linearity over a wide gamma radiation dose that is an important property for radiation dosimetry. Among all fibers used in this study, 100 μm core diameter fiber provides highest response that is 2.6 times than that of smallest core (20 μm core) optical fiber. These fiber-samples demonstrate better response than commercial multi-mode optical fiber and also provide low degree of fading about 20% over a period of fifteen days for gamma radiation. Effective atomic number (Z eff ) is found in the range (13.25–13.69) which is higher than soft tissue (7.5) however within the range of human-bone (11.6–13.8). All the fibers can also be re-used several times as a detector after annealing. TL properties of the Ge-doped optical fibers indicate promising applications in

  11. Microwave detector

    Science.gov (United States)

    Meldner, H.W.; Cusson, R.Y.; Johnson, R.M.

    1985-02-08

    A microwave detector is provided for measuring the envelope shape of a microwave pulse comprised of high-frequency oscillations. A biased ferrite produces a magnetization field flux that links a B-dot loop. The magnetic field of the microwave pulse participates in the formation of the magnetization field flux. High-frequency insensitive means are provided for measuring electric voltage or current induced in the B-dot loop. The recorded output of the detector is proportional to the time derivative of the square of the envelope shape of the microwave pulse.

  12. Vertex detectors

    International Nuclear Information System (INIS)

    Lueth, V.

    1992-07-01

    The purpose of a vertex detector is to measure position and angles of charged particle tracks to sufficient precision so as to be able to separate tracks originating from decay vertices from those produced at the interaction vertex. Such measurements are interesting because they permit the detection of weakly decaying particles with lifetimes down to 10 -13 s, among them the τ lepton and charm and beauty hadrons. These two lectures are intended to introduce the reader to the different techniques for the detection of secondary vertices that have been developed over the past decades. The first lecture includes a brief introduction to the methods used to detect secondary vertices and to estimate particle lifetimes. It describes the traditional technologies, based on photographic recording in emulsions and on film of bubble chambers, and introduces fast electronic registration of signals derived from scintillating fibers, drift chambers and gaseous micro-strip chambers. The second lecture is devoted to solid state detectors. It begins with a brief introduction into semiconductor devices, and then describes the application of large arrays of strip and pixel diodes for charged particle tracking. These lectures can only serve as an introduction the topic of vertex detectors. Time and space do not allow for an in-depth coverage of many of the interesting aspects of vertex detector design and operation

  13. Smoke detectors

    International Nuclear Information System (INIS)

    Macdonald, E.

    1976-01-01

    A smoke detector is described consisting of a ventilated ionisation chamber having a number of electrodes and containing a radioactive source in the form of a foil supported on the surface of the electrodes. This electrode consists of a plastic material treated with graphite to render it electrically conductive. (U.K.)

  14. MTS-6 detectors calibration by using 239Pu-Be neutron source.

    Science.gov (United States)

    Wrzesień, Małgorzata; Albiniak, Łukasz; Al-Hameed, Hiba

    2017-10-17

    Thermoluminescent detectors, type MTS-6, containing isotope 6Li (lithium) are sensitive in the range of thermal neutron energy; the 239Pu-Be (plutonium-and-beryllium) source emits neutrons in the energy range from 1 to 11 MeV. These seemingly contradictory elements may be combined by using the paraffin moderator, a determined density of thermal neutrons in the paraffin block and a conversion coefficient neutron flux to kerma, not forgetting the simultaneous registration of the photon radiation inseparable from the companion neutron radiation. The main aim of this work is to present the idea of calibration of thermoluminescent detectors that consist of a 6Li isotope, by using 239Pu-Be neutron radiation source. In this work, MTS-6 and MTS-7 thermoluminescent detectors and a plutonium-and-beryllium (239Pu-Be) neutron source were used. Paraffin wax fills the block, acting as a moderator. The calibration idea was based on the determination of dose equivalent rate based on the average kerma rate calculated taking into account the empirically determined function describing the density of thermal neutron flux in the paraffin block and a conversion coefficient neutron flux to kerma. The calculated value of the thermal neutron flux density was 1817.5 neutrons/cm2/s and the average value of kerma rate determined on this basis amounted to 244 μGy/h, and the dose equivalent rate 610 μSv/h. The calculated value allowed for the assessment of the length of time of exposure of the detectors directly in the paraffin block. The calibration coefficient for the used batch of detectors is (6.80±0.42)×10-7 Sv/impulse. Med Pr 2017;68(6):705-710. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  15. Archaeological and Geological dating by means of thermoluminescence

    International Nuclear Information System (INIS)

    Gonzalez M, P.R.

    1999-01-01

    In this thesis an specific method for dating local archaeological and geological samples based on the phenomenon of thermoluminescence (TL) using the fine grain and quartz inclusion techniques is developed. Taking into account that this work is interesting for professionals working in the fields of Physics, Chemistry, Archaeology, Anthropology and related sciences, some basic concepts are described to have a better comprehension. Chapter 1 describes the concept of radioactivity, remarking the importance of the different decay types as well as the main radioactive series and the energy liberated in the process. The causes of radioactive desequilibrium are also considered in the case for radon. Another important aspect taken into account in this chapter is the radioisotope production and its relationship with the neutron activation analysis used for the determination of the Uranium and Thorium concentrations in the samples. The TL phenomenon is described in Chapter 2, emphasizing the importance of the process of thermally stimulated luminescence best known as TL and its application for dating minerals of different origin. Chapter 3 shows some important antecedents remarking some aspects of the techniques commonly used for dating purposes. Chapter 4 shows the different methods used for the sample preparation. The techniques used for the 40 K, 238 U and 232 Th determination as well as for the cosmic radiation measurement using locally made TLD are also described. The methods used for the determination of the paleodosis as a function of the TL intensity of each sample are described: special emphasis is taken on the moisture effects as well as in the error limits in the age estimation. Results and conclusions of this study are presented in Chapter 5. These results gave an age of 980 ± 90 years for the Edzna ceramic and 1520 ± 90 years for the Calixtlahuaca ceramics. The age of the Teotihuacan ceramics was not estimated due to the lack of a stable region of the traps

  16. Production of LiF films for dosimetric thermoluminescence application

    International Nuclear Information System (INIS)

    Mauricio, Claudia Lucia de Pinho

    2000-12-01

    This work studies the LiF monolayer and multilayer polycrystalline film's dosimetric properties. The films were produced by electron beam evaporation technique in aluminium and stainless steel substrates maintained at several temperatures. As dosimetric variable, the intensity of the thermoluminescent (TL) glow curve of the films was used. effects of the substrate type and temperature; of the addition of layers of Mg F 2 NaF and Cu F 2 to the LiF films; and of thermal treatments in the TL response of the produced films were studied. The microstructural characterization of the films was accomplished through measures of scanning electronic microscopy and grazing incidence X-rays diffraction analysis. The dosimetric characterization was made of gamma radiation exposure in a 60 Co source, with kerma from 0,1 to 500 Gy. Studies of reproducibility, homogeneity, stability and other environmental effects were also made. LiF and Cu F 2 : LiF; Mg F 2 films were the only ones that presented mechanical stability and reproducibility of the TL emission. There is a strong indication of some correlation between the residual tension fields inside the films and the intensity of its TL emission peaks. LiF monolayer films present supralinear behaviour from 0,2 to 100 Gy. These films present a main TL glow peak around 150 deg C, whose half-time is about 30 days. Its volumetric sensitivity can reach about 60 times that of LiF powder and about 0,25 that of TLD100 (LiF:Mg, Ti commercial dosimeter from Harshaw Chemical Co.) The homogeneity and reproducibility inside a same film batch is better than 12% for 95% confidence level. Cu F 2 : LiF: Mg F 2 films present linear behaviour from 3 to 500 Gy and its main TL glow peak around 200 deg C did not present any fading for a a period of 30 days, in laboratory conditions. This glow peak is characteristic of the Mg doping of LiF, which confirms the diffusion of Mg ions from the Mg F 2 layer to the LiF layer. The TL volumetric sensitivity of these

  17. Thermal neutron detection by activation of CaSO4:Dy + KBr thermoluminescent phosphors

    International Nuclear Information System (INIS)

    Gordon, A.M.P.L.; Muccillo, R.

    1979-01-01

    Thermoluminescence (TL) studies to detect thermal neutrons were performed in cold-pressed CaSO 4 :0,1%Dy + KBr samples. The detection is based on the self-irradiation of the CaSO 4 :Dy TL phosphor by the Br isotopes activated by exposure to a mixed neutron-gamma field. (Author) [pt

  18. Synthesis and thermoluminescence of LaAlO3:Pr3+ to UVC radiation dosimetry

    International Nuclear Information System (INIS)

    Morales-Hernández, A.; Zarate-Medina, J.; Contreras-García, M.E.; Azorín-Nieto, J.; Rivera-Montalvo, T.

    2016-01-01

    Thermoluminescent (TL) response of trivalent praseodymium ion doped lanthanum aluminate (LaAlO 3 :Pr 3+ ) obtained by Pechini method and Spray Dryer was studied. TL response of LaAlO 3 :Pr 3+ powders submitted at 1600 °C exhibited one peak centered at 157 °C. Sensitivity of LaAlO 3 :Pr 3+ was improved in around 90 times compared with undoped LaAlO 3 . TL response as a function of wavelength showed a maximum in 230 nm. Dosimetric characteristics of LaAlO 3 :Pr 3+ under UVR radiation effects were analyzed. Evaluation of activation energy was obtained by Glow Fit v.1.3 software. Experimental results about thermoluminescent characteristics of LaAlO 3 :Pr 3+ suggest as good candidate to be employed as a complementary thermoluminescent device with other TL phosphors as aluminum oxide - Highlights: • High sensitivity of new phosphor to UVC dosimetry was is studied. • Thermoluminescence response of LaAlO 3 :Pr 3+ is presented. • LaAlO 3 :Pr 3+ is suggested as UVCR dosimeter. • TL response of LaAlO 3 :Pr 3+ has dependence on sintering temperature.

  19. Studies on 192Ir afterloading irradiation of the canine prostate with special consideration of thermoluminescent dosimetry

    International Nuclear Information System (INIS)

    Reuter, M.

    1986-01-01

    A method for high dose rate afterloading irradiation of the prostate with iridium 192 was developed. The isodoses of the urethra and rectum, which were measured by means of thermoluminescent dosimetry, showed deviations from the doses pre-calculated by computer (BRACHY), because this calculation is based on an anatomically ideal condition. (MBC) [de

  20. Thermoluminescence of ZrSiO4 (zircon) : A new dating method?

    NARCIS (Netherlands)

    van Es, H.J.; Vainshtein, D.I.; Rozendaal, A.; Donoghue, J.F.; de Meijer, R.J.; den Hartog, H.W

    2002-01-01

    Zircon appears to be a suitable medium for thermoluminescence (TL) dating of sediments from the Quaternary. TL of zircon results predominantly from internal irradiation, due to the relatively high internal concentrations of α-emitting U and Th. The internal dose predominates over the external one

  1. Simulation of the effects of the dose rate and temperature on zircon thermoluminescence

    NARCIS (Netherlands)

    Turkin, A.A.; Es, H.J. van; Vainshtein, D.I.; Hartog, H.W. den

    2005-01-01

    After exposure to ionizing irradiation, mineral zircon exhibits thermoluminescence (TL), which can be used to calculate the irradiation dose and the age of natural samples. Different aspects of the dating procedure based on zircon TL, including laboratory added irradiation at room and elevated

  2. Thermoluminescence and optically stimulated luminescence of gamma-irradiated mineral zircon

    NARCIS (Netherlands)

    Secu, M.; Vainshtein, D.; Turkin, A.A.; Hartog, H.W. den

    2007-01-01

    Thermoluminescence (TL) manifested by gamma-irradiated mineral zircon has shown a strong TL peak at about 165 °C which is due to recombination of electrons and Dy3+ related shallow hole traps. After they have been removed by a short preheat we have observed two TL peaks at 300-320 °C and ≈420 °C,

  3. Preparation of new thermoluminescent material (100− x) B2O3 ...

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science; Volume 39; Issue 1. Preparation of new thermoluminescent material ( 100 − x )B 2 O 3 –xLi 2 O: Cu 2 + for sensing and detection of radiation. Zeid A Alothman Tansir Ahamad Mu Naushad Saad M Alshehri. Volume 39 Issue 1 February 2016 pp 331-336 ...

  4. Thermally stimulated conductivity and thermoluminescence from Al2O3 : C

    DEFF Research Database (Denmark)

    Agersnap Larsen, N.; Bøtter-Jensen, L.; McKeever, S.W.S.

    1999-01-01

    Simultaneous measurements of thermoluminescence (TL) and thermally stimulated conductivity (TSC) are reported on single-crystal dosimetry-quality Al2O3:C following gamma irradiation at room temperature. Analysis of the data reveals a superposition of several first-order TL and TSC peaks caused...

  5. Characterization of the personal thermoluminescent dosemeter of LiF: Mg, Ti + Ptfe

    International Nuclear Information System (INIS)

    Azorin N, J.; Gutierrez C, A.; Gonzalez M, P.

    1991-01-01

    The objective of this work is to characterize the thermoluminescent dosemeters taken place in the laboratory in form of pellets of LiF: Mg, Ti + Ptfe like personal dosemeters, subjecting them to the operation tests proposed by the international standards and comparing them with the TLD-100, the Tl dosemeter more used at the moment for personal dosimetry

  6. The Orbital Distribution of Meteorites Based on High Temperature Thermoluminescence. 1; Theory and Modern Falls

    Science.gov (United States)

    Benoit, P. H.; Sears, D. W. G.

    2001-01-01

    Like 250 C Thermoluminescence (TL) data, 400 C TL levels of modern falls largely reflect solar heating, and thus perihelia. The 400 C data offers additional constraints on orbital information for ordinary chondrites. Additional information is contained in the original extended abstract.

  7. Year 2000 compliance concerns with the ISA Thermoluminescent Dosimetry Data Processing (TL-DP) software system

    Energy Technology Data Exchange (ETDEWEB)

    Saviz, K.

    1998-05-26

    The year 2000 is rapidly approaching, and there is a good chance that computer systems that utilize two digit year dates will experience problems in retrieval of date information. The ISA Thermoluminescent Dosimetry Data Processing (TL-DP) software and computer system has been reviewed for Year 2000 compliance issues.

  8. Utilization of thermoluminescent dosemeters in radiation field studies for different materials

    International Nuclear Information System (INIS)

    Carron, W.; Guilardi Neto, T.

    1987-01-01

    The dose conversion factor of lithium fluoride thermoluminescent for the follows materials: water, wood and soil, the dose curve surveying in function of depth and the regression equations that better adapt to the dose curves were calculated. (C.G.C.) [pt

  9. Thermal and radiation history of meteorites as revealed by their thermoluminescence records

    International Nuclear Information System (INIS)

    Bhandari, N.

    1985-01-01

    Attempts are described to derive information about important parameters of the thermal and radiation history of meteorites from a study of depth profile of thermoluminescence coupled to appropriate annealing studies. In this review some possibilities are examined, emphasizing various factors cardinal to any meaningful application of TL in meteoritics. (author)

  10. Dose profile measurement in computerized axial tomography equipment using thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Azorin V, J.C.; Falcony, C.; Azorin N, J.

    2000-01-01

    In this work are presented the results about measuring the radiation dose profile in two equipment of computerized axial tomography (Tac). Thermoluminescent dosemeters (Dtl) of LiF, Mg, Cu, P + Ptfe in form of disks were used which were developed and made in Mexico. The results showed that Dtl are appropriated for these type of studies. (Author)

  11. Energy absorption buildup factors for thermoluminescent dosimetric materials and their tissue equivalence

    DEFF Research Database (Denmark)

    Manohara, S.R.; Hanagodimath, S.M.; Gerward, Leif

    2010-01-01

    Gamma ray energy-absorption buildup factors were computed using the five-parameter geometric progression (G-P) fitting formula for seven thermoluminescent dosimetric (TLD) materials in the energy range 0.015-15 MeV, and for penetration depths up to 40 mfp (mean free path). The generated energy-absorption...

  12. Ambiente sociomoral e desenvolvimento da autonomia

    OpenAIRE

    Jakeline Alencar Andrade

    2003-01-01

    Esta dissertação aborda as relações entre o ambiente sociomoral e o desenvolvimento da autonomia das crianças de uma Escola da comunidade do Município de Porto Alegre-RS. O objetivo é descrever o ambiente sociomoral de cada sala de aula, construído nas relações interindividuais entre professores e alunos, e analisar o desenvolvimento da autonomia das crianças através do estudo do juízo moral. A pesquisa teórica fundamenta-se em vários estudos e abordagens sobre a moralidade e, em especial, no...

  13. Desenvolvimento Symbian na plataforma serie 60

    OpenAIRE

    Iida, Renato Faria

    2006-01-01

    Com o rápido avanço da tecnologia dos terminais celulares e a integração de funções de handhelds aos celulares, criam-se novas possibilidades de aplicações móveis. Atualmente existem várias linhas de desenvolvimento. As três principais linguagens são: · Symbian C++ · Java 2 Micro Edition · BREW O foco desse trabalho é mostrar o ciclo de desenvolvimento do Symbian C++ aplicado para aplicações baseadas em localização. O primeiro passo é entender a origem e as características básicas da linguage...

  14. Semiconductor Detectors; Detectores de Semiconductores

    Energy Technology Data Exchange (ETDEWEB)

    Cortina, E.

    2007-07-01

    Particle detectors based on semiconductor materials are among the few devices used for particle detection that are available to the public at large. In fact we are surrounded by them in our daily lives: they are used in photoelectric cells for opening doors, in digital photographic and video camera, and in bar code readers at supermarket cash registers. (Author)

  15. Desenvolvimento larval de Brycon hilarii (Characiformes, Characidae

    Directory of Open Access Journals (Sweden)

    Fernando G. de Oliveira

    2012-03-01

    Full Text Available O presente estudo caracterizou o desenvolvimento inicial de Brycon hilarii (Valenciennes, 1850 através de caracteres morfométricos e merísticos e analisou as relações entre as características morfométricas das larvas ao longo do desenvolvimento usando modelos de regressão linear, quadrática e linear por partes. O material foi obtido nas bacias dos rios Cuiabá e Manso, Mato Grosso, Brasil, entre março de 2000 e março de 2004. Os indivíduos foram identificados e separados de acordo com o grau de desenvolvimento da notocorda e, posteriormente, medidos e contados os caracteres morfométricos e merísticos, respectivamente. O comprimento padrão variou entre 3,25 e 26,00 mm. Inicialmente, as larvas apresentaram maior concentração de pigmentos dendríticos ao longo do intestino e, em flexão e pós-flexão, intensificaram-se no dorso do corpo. Uma mancha umeral e outra no pedúnculo caudal foram observadas no final do estágio de pós-flexão. O intestino apresentou-se longo, o focinho curto, o órgão adesivo presente em larval vitelino e pré-flexão e a boca terminal por todo o desenvolvimento. O número total de miômeros variou de 41 a 50 (23 a 30 pré e 16 a 24 pós-anal. O número de raios das nadadeiras foi: dorsal 11; anal 30; peitoral 15 e ventral oito. A análise do crescimento indicou maior metamorfose no estágio de flexão.

  16. ECO-92: MEIO AMBIENTE E DESENVOLVIMENTO

    Directory of Open Access Journals (Sweden)

    . Editorial

    1992-01-01

    Full Text Available A cidade do Rio de Janeiro transformou-se durante alguns dias em capital mundial da ecologia. Lá se debateu o problema — tão angustiante para a humanidade de hoje — de conciliar ecologia e desenvolvimento. Sena deturpar o objetivo deste fórum internacional se o reduzíssemos à defesa da ecologia em detrimento do desenvolvimento. De fato. os dois pólos não são necessariamente irreconciliáveis. embora até o presente o desenvolvimento tenha sido incentivado às custas da destruição e depredação da natureza. As consequências são patentes: morte lenta de rios e mares, poluição sonora e atmosférica das grandes cidades, urbanização caótica e desumana, desmatamento, extinção de milhares de espécies, alterações climáticas, uso desmesurado de defensivos agrícolas, empobrecimento gradativo de solos antes férteis etc.

  17. Neutron detector

    Science.gov (United States)

    Stephan, Andrew C [Knoxville, TN; Jardret,; Vincent, D [Powell, TN

    2011-04-05

    A neutron detector has a volume of neutron moderating material and a plurality of individual neutron sensing elements dispersed at selected locations throughout the moderator, and particularly arranged so that some of the detecting elements are closer to the surface of the moderator assembly and others are more deeply embedded. The arrangement captures some thermalized neutrons that might otherwise be scattered away from a single, centrally located detector element. Different geometrical arrangements may be used while preserving its fundamental characteristics. Different types of neutron sensing elements may be used, which may operate on any of a number of physical principles to perform the function of sensing a neutron, either by a capture or a scattering reaction, and converting that reaction to a detectable signal. High detection efficiency, an ability to acquire spectral information, and directional sensitivity may be obtained.

  18. Particle detectors

    CERN Document Server

    AUTHOR|(CDS)2068232

    1998-01-01

    The lecture series will present and overview of the basic techniques and underlying physical principles of particle detectors, applied to current and future high energy physics experiments. Illustrating examples, mainly from the field of collider experiments, will demonstrate the performance and limitations of the various techniques. After and introduction we shall concentrate on particle tracking. Wire chambers, drift chambers, micro gaseous tracking devices and solid state trackers will be discussed. It follows and overview of scintillators, photon detection, fiber tracking and nuclear emulsions. One lecture will deal with the various techniques of calorimetry. Finally we shall focus on methods developed for particle identification. These comprise specific energy loss, time of flight Cherenkov and transition radiation detectors.

  19. Authenticity test in ceramics and archaeological figures by thermoluminescence; Prueba de Autenticidad en ceramicas y figuras arqueologicas por termoluminiscencia

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez L, A.; Schaaf, P. [Laboratorio de Termoluminiscencia, Instituto de Geofisica-UNAM (Mexico); Filloy, L. [Museo Nacional de Antropologia e Historia, Ciudad de Mexico (Mexico)

    1999-07-01

    At present exists quite a lot of false archaeological pieces which provokes doubts about the legitimacy of the pieces. In this work it is presented the Authenticity test by Thermoluminescence realized at the urn of the goddess 13 serpent of the zapotec culture of Oaxaca which is exposed in Mexico City. The original piece contains crystalline structures which present hardly the thermoluminescence phenomena by the presence of {sup 238} U, {sup 232} Th, and {sup 40} K getting with this the form and intensity of the natural thermoluminescence curve of an archaeological piece which shows a Tl peak and allows to know so if it was made recently or not. (Author)

  20. New color-photographic observation of thermoluminescence from sliced rock samples

    International Nuclear Information System (INIS)

    Hashimoto, Tetsuo; Kimura, Kenichi; Koyanagi, Akira; Takahashi, Kuniaki; Sotobayashi, Takeshi

    1983-01-01

    New observation technique has been established for the thermoluminescence photography using extremely high-sensitive color films. Considering future application to the geological fields, a granite was selected as a testing material. The sliced specimens (0.5--0.7 mm in thickness), which were irradiated with a 60 Co source, were mounted on the heater attached with a thermocouple, which was connected to a microcomputer for measuring the temperature. The samples were heated in the temperature range of 80--400 0 C by operating the camera-shutter controlled with the microcomputer. Four commercially available films (Kodak-1000(ASA), -400, Sakura-400, Fuji-400) could give apparently detectable color-images of artificial thermoluminescence above a total absorbed dose of 880 Gy(88 krad). The specimens, irradiated upto 8.4 kGy(840krad), allowed easily to distinguish the distinct appearance of the thermoluminescence images depending on kinds of white mineral constituents. Moreover, such color images were changeable with the heating temperature. Sakura-400 film has proved the most colorful images from aspects of color tone although Kodak-1000 film showed the highest sensitivity. By applying this Kodak-1000, it was found that the characteristic color image due to natural thermoluminescence was significantly observed on the Precambrian granite which was exposed with natural radiation alone since its formation. This simple and interesting technique, obtainable surface information reflecting impurities and local crystal defects in addition to small mineral constituents, was named as the thermoluminescence color imaging (abbreviated to TLCI) technique by the authors and its versatile applications were discussed. (author)

  1. MUST detector

    International Nuclear Information System (INIS)

    Blumenfeld, Y.; Auger, F.; Sauvestre, J.E.

    1999-01-01

    The IPN-Orsay, in collaboration with the SPhN-Saclay and the DPTA Bruyeres, has built an array of 8 telescopes based on Si-strip technology for the study of direct reactions induced by radioactive beams. The detectors are described, along with the compact high density VXI electronics and the stand-alone data acquisition system developed in the laboratory. One telescope was tested using an 40 Ar beam and the measured performances are discussed. (authors)

  2. Desenvolvimento econômico, desigualdade e saúde

    Directory of Open Access Journals (Sweden)

    Pedro Reginaldo Prata

    1994-09-01

    Full Text Available O autor se refere a dimensão socioeconômica, individual e coletiva do fenômeno saúde-doença. Refere-se também ao fato das populações estarem sobre a influência desigual de fatores de risco e de proteção à saúde. Discute as desigualdades no desenvolvimento e a relação entre desenvolvimento, riqueza, saúde e justiça social. Questiona as teorias de desenvolvimento econômico, diferenciando desenvolvimento de crescimento. Cunha os conceitos de armadilha do desenvolvimento e refugiados sociais. Define uma comunidade saudável. Propõe a necessidade de mudança no modelo de desenvolvimento. Baliza o papel e as limitações do setor saúde no que diz respeito a iniqüidade social.

  3. Desenvolvimento econômico, desigualdade e saúde

    Directory of Open Access Journals (Sweden)

    Prata Pedro Reginaldo

    1994-01-01

    Full Text Available O autor se refere a dimensão socioeconômica, individual e coletiva do fenômeno saúde-doença. Refere-se também ao fato das populações estarem sobre a influência desigual de fatores de risco e de proteção à saúde. Discute as desigualdades no desenvolvimento e a relação entre desenvolvimento, riqueza, saúde e justiça social. Questiona as teorias de desenvolvimento econômico, diferenciando desenvolvimento de crescimento. Cunha os conceitos de armadilha do desenvolvimento e refugiados sociais. Define uma comunidade saudável. Propõe a necessidade de mudança no modelo de desenvolvimento. Baliza o papel e as limitações do setor saúde no que diz respeito a iniqüidade social.

  4. Desenvolvimento motor e autoconceito de escolares com transtorno do desenvolvimento da coordenação

    OpenAIRE

    Beltrame, Thais Silva; Cardoso, Fernando Luiz; Alexandre, Juliano Maestri; Bernardi, Carla Simon

    2016-01-01

    Resumo Verificou-se a influência de um programa de intervenção motora no desenvolvimento motor e autoconceito de escolares com Transtorno do Desenvolvimento da Coordenação (TDC). Participaram do programa de intervenção de 16 semanas,12 crianças com idades de 10 anos (± 6 meses), divididas em dois grupos;sete escolares com indicativo TDC (GT) e cinco escolares com risco para TDC (GR). Utilizou-se a bateria motora MABC-2 (Henderson, Sugden, & Barnett, 2007) e a Escala de Auto-percepção para Cri...

  5. Angular dependence of TL and OSL responses of Al{sub 2}O{sub 3}:C commercial detectors in standard beta radiation beams

    Energy Technology Data Exchange (ETDEWEB)

    Antonio, Patricia L.; Caldas, Linda V.E., E-mail: patrilan@ipen.br, E-mail: lcaldas@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2014-07-01

    The luminescent response of radiation detectors was evaluated by means of the thermoluminescence (TL) and optically stimulated luminescence (OSL) phenomena, for verification of its application in radiation dosimetry. An angular dependence study was performed in this work, using Al{sub 2}O{sub 3}:C commercial detectors, which were exposed to the radiation beams of a {sup 90}Sr +{sup 90}Y source from a beta radiation secondary standard system. The detectors were irradiated with an angle variation from -60° to +60°, and the results obtained using the TL and OSL techniques were within the international recommendation limits. (author)

  6. Burnout detector design for heat transfer experiments

    International Nuclear Information System (INIS)

    Dias, H.F.

    1992-01-01

    This paper describes the design of an burnout detector for heat transfer experiments, applied during tests for optimization of fuel elements for PWR reactors. The burnout detector avoids the fuel rods destruction during the experiments at the Centro de Desenvolvimento da Tecnologia Nuclear. The detector evaluates the temperature changes over the fuel rods in the temperature changes over the fuel rods in the area where the burnout phenomenon could be anticipated. As soon as the phenomenon appears, the system power supply is turned off. The thermal Circuit No. 1, during the experiments, had been composed by nine fuel rods feed parallelly by the same power supply. Fine copper wires had been attached at the centre and at the ends of the fuel rod to take two Wheat stone bridge arms. The detector had been applied across the bridge diagonals, which must be balanced the burnout excursion can be detected as a small but fast increase of the signal over the detector. Large scale experiments had been carried out to compare the resistance bridge performance against a thermocouple attached through the fuel rod wall. These experiments had been showed us the advantages of the first method over the last, because the bridge evaluates the whole fuel rod, while the thermocouple evaluates only the area where it had been attached. (author)

  7. Improving neutron dosimetry using bubble detector technology

    International Nuclear Information System (INIS)

    Buckner, M.A.

    1993-02-01

    Providing accurate neutron dosimetry for a variety of neutron energy spectra is a formidable task for any dosimetry system. Unless something is known about the neutron spectrum prior to processing the dosimeter, the calculated dose may vary greatly from that actually encountered; that is until now. The entrance of bubble detector technology into the field of neutron dosimetry has eliminated the necessity of having an a priori knowledge of the neutron energy spectra. Recently, a new approach in measuring personnel neutron dose equivalent was developed at Oak Ridge National Laboratory. By using bubble detectors in combination with current thermoluminescent dosimeters (TLDs) as a Combination Personnel Neutron Dosimeter (CPND), not only is it possible to provide accurate dose equivalent results, but a simple four-interval neutron energy spectrum is obtained as well. The components of the CPND are a Harshaw albedo TLD and two bubble detectors with theoretical energy thresholds of 100 key and 1500 keV. Presented are (1) a synoptic history surrounding emergence of bubble detector technology, (2) a brief overview of the current theory on mechanisms of interaction, (3) the data and analysis process involved in refining the response functions, (4) performance evaluation of the original CPND and a reevaluation of the same data under the modified method, (5) the procedure used to determine the reference values of component fluence and dose equivalent for field assessment, (6) analysis of the after-modification results, (7) a critique of some currently held assumptions, offering some alternative explanations, and (8) thoughts concerning potential applications and directions for future research

  8. Improving neutron dosimetry using bubble detector technology

    Energy Technology Data Exchange (ETDEWEB)

    Buckner, M.A.

    1993-02-01

    Providing accurate neutron dosimetry for a variety of neutron energy spectra is a formidable task for any dosimetry system. Unless something is known about the neutron spectrum prior to processing the dosimeter, the calculated dose may vary greatly from that actually encountered; that is until now. The entrance of bubble detector technology into the field of neutron dosimetry has eliminated the necessity of having an a priori knowledge of the neutron energy spectra. Recently, a new approach in measuring personnel neutron dose equivalent was developed at Oak Ridge National Laboratory. By using bubble detectors in combination with current thermoluminescent dosimeters (TLDs) as a Combination Personnel Neutron Dosimeter (CPND), not only is it possible to provide accurate dose equivalent results, but a simple four-interval neutron energy spectrum is obtained as well. The components of the CPND are a Harshaw albedo TLD and two bubble detectors with theoretical energy thresholds of 100 key and 1500 keV. Presented are (1) a synoptic history surrounding emergence of bubble detector technology, (2) a brief overview of the current theory on mechanisms of interaction, (3) the data and analysis process involved in refining the response functions, (4) performance evaluation of the original CPND and a reevaluation of the same data under the modified method, (5) the procedure used to determine the reference values of component fluence and dose equivalent for field assessment, (6) analysis of the after-modification results, (7) a critique of some currently held assumptions, offering some alternative explanations, and (8) thoughts concerning potential applications and directions for future research.

  9. Environmental radiation monitoring of nuclear sites by thermoluminescent dosimeters (TLD)

    International Nuclear Information System (INIS)

    Duftschmid, K.E.; Strachotinsky, Ch.

    1978-04-01

    The measurement of environmental radiation doses around nuclear facilities requires the detection of few mrem/year. The properties of the automatic TLD-system Harshaw Mod. 2271 for such measurements have been evaluated under practical conditions and optimized techniques derived. The automatic TLD-system is based on LiF dosimeter cards with two crystals providing gamma and beta dose values. Limit of detection defined as three standard deviations of residuel dose is 1,2 mR. Automatic readout combined with electronic data evaluation are especially useful for large monitoring networks. Practical intercomparisons of this dosimeter with bulb-type CaF 2 detectors have been performed showing good agreement of both detector. Although bulb-dosimeters proved to be extremely sensitive with a limit of detection at 0,012 mR which makes them very suitable for very short exposure times, the automatic LiF system is superior in regards of man power requirement if monthly monitoring periods are sufficient. The system has been tested in practice during two international intercomparisons performed by the US Department of Energy - Health and Safety Laboratory New York and the Physikalisch Technische Bundesanstalt Braunschweig, Germany, showing excellent agreement. Furthermore a routine monitoring network consisting of 12 measurement positions around the Research Center Seibersdorf has been operated with this technique since more than two years. (author)

  10. Semiconductor scintillator detector for gamma radiation

    International Nuclear Information System (INIS)

    Laan, F.T.V. der; Borges, V.; Zabadal, J.R.S.

    2015-01-01

    Nowadays the devices employed to evaluate individual radiation exposition are based on dosimetric films and thermoluminescent crystals, whose measurements must be processed in specific transductors. Hence, these devices carry out indirect measurements. Although a new generation of detectors based on semiconductors which are employed in EPD's (Electronic Personal Dosemeters) being yet available, it high producing costs and large dimensions prevents the application in personal dosimetry. Recent research works reports the development of new detection devices based on photovoltaic PIN diodes, which were successfully employed for detecting and monitoring exposition to X rays. In this work, we step forward by coupling a 2mm anthracene scintillator NE1, which converts the high energy radiation in visible light, generating a Strong signal which allows dispensing the use of photomultipliers. A low gain high performance amplifier and a digital acquisition device are employed to measure instantaneous and cumulative doses for energies ranging from X rays to Gamma radiation up to 2 MeV. One of the most important features of the PIN diode relies in the fact that it can be employed as a detector for ionization radiation, since it requires a small energy amount for releasing electrons. Since the photodiode does not amplify the corresponding photon current, it must be coupled to a low gain amplifier. Therefore, the new sensor works as a scintillator coupled with a photodiode PIN. Preliminary experiments are being performed with this sensor, showing good results for a wide range of energy spectrum. (author)

  11. Applicability of thermoluminescent dosimeters in X-ray organ dose determination and in the dosimetry of systemic and boron neutron capture radiotherapy

    International Nuclear Information System (INIS)

    Aschan, C.

    1999-01-01

    The main detectors used for clinical dosimetry are ionisation chambers and semiconductors. Thermoluminescent (TL) dosimeters are also of interest because of their following advantages: (i) wide useful dose range, (ii) small physical size, (iii) no need for high voltage or cables, i.e. stand alone character, and (iv) tissue equivalence (LiF) for most radiation types. TL detectors can particularly be used for the absorbed dose measurements performed with the aim to investigate cases where dose prediction is difficult and not as part of a routine verification procedure. In this thesis, the applicability of TL detectors was studied in different clinical applications. Particularly, the major phenomena (e.g. energy dependence, sensitivity to high LET radiation, reproducibility) affecting on the precision and accuracy of TL detectors in the dose estimations were considered in this work. In organ dose determinations of diagnostic X-ray examinations, the TL detectors were found to be accurate within 5% (1 S.D.). For in viva studies using internal irradiation source, i.e. for systemic radiation therapy, a method for determining the absorbed doses to organs was introduced. The TL method developed was found to be able to estimate the absorbed doses to those critical organs near the body surface within 50%. In the mixed neutron-gamma field of boron neutron capture therapy (BNCT), TL detectors were used for gamma dose and neutron fluence measurements. They were found able to measure the neutron dose component with the accuracy of 16%, and therefore to be a useful addition to the activation foils in BNCT neutron dosimetry. The absorbed gamma doses can be measured with TL detectors within 20% in the mixed neutron-gamma field, which enables in viva measurements at BNCT beams with approximately the same accuracy. In this study, the uncertainties of TL dosimeters were found to be high but not essentially greater than those in other measurement techniques used for clinical dosimetry

  12. Measurement of depth dose factors for various 60-Co and X-ray beams using ion chambers and thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Milu, C.

    1983-06-01

    As the depth dose factors may vary with the type of 60 Co unit (or X-ray generator) several determinations in this direction were done. The depth doses (mGy/s) for 60 Co beam (SSD=80cm) for the depths 5,10,15 and 20 cm were 11.92, 8.25, 5.75 and resp. 4.10 for field size 10x10 cm and 12.70, 9.42, 6.63 and resp. 4.93 for field size 20x20 cm. In X-ray beam, the depth doses (mGy/s) for FSD=50 cm, open-end and field size 10 cm diam. were: 1.78, 0.66, 0.23 and 0.09 for 100 kV (0.143 mm HVL, in air) and depths 5, 10, 15 and resp. 20 cm; 2.61, 1.12, 0.46 and 0.19 for 135 kV and 4.13, 1.88, 0.88 and 0.40 for 180 kV. The quality of the radiation at different depths in the water phantom was determined using a tandem TLD within Cu sleeve and TLD without Cu sleeve. The values obtained ranged from 0.018 mm Cu for 100 kV to 0.170 for 180 kV at depth 5 cm. All determinations were done using an IAEA perspex water tank and Harshaw extruded LiF as detectors. An intercomparison using LiF powder capsules prepared and sent by the IAEA Dosimetry Laboratory was performed too, in order to check the consistency of thermoluminescent dosimetry systems

  13. Analise funcional discriminativa em dislexia do desenvolvimento

    OpenAIRE

    Magda Solange Vanzo Pestun

    2001-01-01

    Resumo: Esta tese teve por objetivos avaliar e analisar através de provas neuropsicológicas, pedagógicas e exames complementares, crianças com possível diagnóstico de Dislexia do Desenvolvimento. Participaram como sujeitos 47 crianças, sendo 27 controles (sem dificuldades de aprendizagem) e 20 experimentais, com idade entre 8 e 13 anos, alunos de 23 série do 10grau de escola da rede pública da região de Campinas, SP. A coleta de dados se deu no HCIUNICAMP para os sujeitos do grupo experimenta...

  14. A brinquedoteca e o desenvolvimento infantil

    OpenAIRE

    Ramalho, Márcia Terezinha de Borja

    2000-01-01

    Dissertação (Mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. O desenvolvimento infantil segundo Piaget e Vygotsky. O Brincar. O jogo. O Brinquedo. A Brincadeira. Brinquedos construídos com sucata. A cultura infantil. Pesquisa de Campo incluindo uma amostra de nove brinquedotecas em Florianópolis-Santa Catarina em Instituições de Educação Infantil , abrangendo a faixa etária de 0-6 anos. Atividades desenvolvidas nas brinquedotecas, estrutura, principais brinc...

  15. Desenvolvimento Textil. Malha artesanal e sustentabilidade

    OpenAIRE

    Cacho, Filipa Vieira

    2011-01-01

    Tese de Mestrado em Design de Moda Este projecto, de carácter experimental, visa o desenvolvimento de um novo têxtil que responda às necessidades e preocupações levantadas pelo estilo de vida actual. Ao mesmo tempo, procura inovar o design de malhas artesanal tradicional que tem vindo a viver um revivalismo dentro da moda contemporânea de vanguarda. Uma das maiores preocupações actuais da indústria têxtil, bem como de outras indústrias, é a sustentabilidade, o que se traduz no desenvolvime...

  16. Desenvolvimento aplicacional CRM em Modelo Cloud

    OpenAIRE

    Pinto, Joana Correia

    2017-01-01

    Trabalho de projeto de mestrado, Engenharia Informática (Sistemas de Informação) Universidade de Lisboa, Faculdade de Ciências, 2017 O presente relatório descreve o trabalho realizado no Projeto de Engenharia Informática na empresa Unipartner IT Services, que decorreu desde novembro de 2016. Este trabalho está inserido no âmbito do projeto “Desenvolvimento Aplicacional sobre Modelos Cloud”. Uma solução CRM tem como principais objetivos melhorar as relações entre as empresas e os seus clien...

  17. Desenvolvimento de um novo conceito de refrigerante

    OpenAIRE

    Ribeiro, Tânia Isabel Bragança

    2011-01-01

    Dissertação para obtenção de grau de mestre em Tecnologia e Segurança Alimentar – Qualidade Alimentar A indústria de refrigerantes e sumos é um subsector da indústria de bebidas não-alcoólicas, de grande impacte na economia e elevada competitividade. O desenvolvimento de novos produtos e a garantia de qualidade dos produtos são de extrema importância nesta indústria. Actualmente, o consumidor é bastante preocupado com a saúde, procurando produtos que possam não comprometer e/ou impulsionar...

  18. Thermoluminescence of LaAlO{sub 3}; Termoluminescencia de LaAlO{sub 3}:Dy

    Energy Technology Data Exchange (ETDEWEB)

    Morales H, A.; Zarate M, J. [Universidad Michoacana de San Nicolas de Hidalgo, Instituto de Investigacion en Metalurgia y Materiales, Ciudad Universitaria, Edif. U, 58060 Morelia, Michoacan (Mexico); Rivera M, T. [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Av. Legaria 694, 11500 Mexico D. F. (Mexico); Azorin N, J., E-mail: feyo_yo@hotmail.com [Universidad Autonoma Metropolitana, Unidad Iztapalapa, Av. San Rafael Atlixco 186, Col. Vicentina, 09340 Mexico D. F. (Mexico)

    2015-10-15

    In this paper the thermoluminescent properties of doped lanthanum aluminate (LaAlO{sub 3}) with dysprosium ion (Dy) were studied. The thermoluminescence characteristics in the samples were obtained using an ultraviolet radiation of 220 nm. The LaAlO{sub 3}:Dy samples were prepared by the modified Pechini method (Spray Dryer). The structural and morphological characterization was obtained by X-ray diffraction (XRD) and scanning electron microscopy (Sem) techniques respectively. The size particle composing the agglomerate was determined by Sem, agglomerated particles composed size of 2μm were observed. The thermoluminescence response of LaAlO{sub 3}:Dy was compared with that obtained with the undoped sample. Thermoluminescence brightness curves of LaAlO{sub 3}:Dy showed a peak centered at 185 grades C. Sensitivity of doped sample was greater, about 100 times compared with the undoped sample. Thermoluminescence response in function of the wavelength showed a maximum at 220 nm. Also the fading in thermoluminescence response was studied. (Author)

  19. Thermoluminescent characteristics of diopside-teflon composites for radiation dosimetry

    International Nuclear Information System (INIS)

    Melo, A.P.; Caldas, L.V.E.

    2006-01-01

    Diopside - Teflon composites were been studied in relation to their dosimetric properties for high-dose dosimetry. Diopside from Minas Gerais, Brazil, CaMg(Si 2 O 6 ), was obtained in form of rude mineral with inclusions of quartz. The samples were prepared and only Diopside grains obtained. Pellets of Diopside-Teflon composites were prepared in the proportion of 2(Teflon): 1 (Diopside).The TL response repeatability presented a maximum coefficient of variation of 7.5%. The calibration curve is linear between 0.5 Gy and 1 kGy. TL emission spectra present three emissions of similar intensities at 570 nm, 590 nm and between 610-635 nm. The results suggest that the material presents good characteristics for use as high-dose radiation detectors. (Author)

  20. An improved approach to identify irradiated dog feed by electron paramagnetic resonance study and thermoluminescence measurements

    Energy Technology Data Exchange (ETDEWEB)

    Sanyal, Bhaskar, E-mail: bhaskar_sanyal@rediffmail.co [Food Technology Division, Bhabha Atomic Research Centre, Mumbai-400 085 (India); Chawla, S.P.; Sharma, Arun [Food Technology Division, Bhabha Atomic Research Centre, Mumbai-400 085 (India)

    2011-05-15

    In the present study, probably for the first time, a detailed analysis of the radiation induced radical species and thermoluminescence measurements of irradiated dog feed are reported. The EPR spectrum of non-irradiated ready-to-eat dog feed was characterized by singlet g=2.0047{+-}0.0003. Irradiated samples exhibited a complex EPR spectrum. During high power (50.0 mW) EPR spectroscopy, a visible change in the shape of the EPR spectrum was observed and characterized by EPR spectrum simulation technique. An axially symmetric anisotropic signal with g{sub ||}=2.0028 and g{sub perpendicular}=1.9976 was identified. However, a negligible change in the matrix of irradiated edible dog chew was observed using EPR spectroscopy. Therefore, thermoluminescence study of the isolated minerals from dog chew was carried out. The composition of the poly-minerals was studied using SEM and EDX analysis and a complete verdict on identification of irradiation is proposed.

  1. Thermoluminescence induced by X-rays in silica materials with metallic impurities

    International Nuclear Information System (INIS)

    Mendoza A, D.; Gonzalez M, P.; Espinosa P, M.; Salas, P.; Castano, V.M.

    1999-01-01

    Diverse materials of silica with Fe, Cu, Mg, and Mn impurities were synthesized by the sol-gel method, using tetraethyl orthosilicate as precursor. The materials obtained were subjected to thermal treatment at 500, 700 and 1000 Centigrade also they were irradiated with X-ray generated by a X-ray diffractometer which is installed in the ININ. The thermoluminescent signal was analysed and correlated with the type of impurities that are present in the material and with the grade of crystallinity produced by the thermal treatment in them. In according to the results obtained these materials show a thermoluminescent signal which is influenced by the crystallinity grade. It was analysed the behavior of the response for different doses, with the purpose of utilizing them to quantify very intense fields of radiation. (Author)

  2. Thermoluminescent properties of CaSO{sub 4}:Dy prepared by precipitation method

    Energy Technology Data Exchange (ETDEWEB)

    Roman, J.; Rivera, T. [Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, IPN, Av. Legaria 694, Col. Irrigacion, 11500 Mexico D. F. (Mexico); Azorin, J. [Universidad Autonoma Metropolitana, Unidad Iztapalapa, Av. San Rafael Atlixco 186, Col. Vicentina, 09340 Mexico D. F. (Mexico)], e-mail: holand_jeos@hotmail.com

    2009-10-15

    This paper reports the synthesis and thermoluminescent (Tl) characterization of CaSO{sub 4}:Dy obtained by the precipitation method. Thermoluminescent CaSO{sub 4}:Dy powder and Teflon (PTFE) were mixed in order to obtain samples in pellets form. Samples of CaSO{sub 4}:Dy were exposed to a radiation gamma source of {sup 60}Co and {sup 90}Sr beta particles. Tl response of CaSO{sub 4}:Dy showed a glow curve with two peaks centered at around 164 and 302 C. Tl phosphor showed a good linearity in the range from 0.5 to 30 Gy. Fading of the Tl information was 5.19 % in 37 days and presented a standard deviation of 4% for reproducibility. (Author)

  3. Thermoluminescence of sulfated zircon exposed to gamma radiation; Termoluminiscencia de circonia sulfatada expuesta a radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Rubio, E.; Castano, V.M. [Centro de Fisica Aplicada y Tecnologia Avanzada, UNAM, A.P. 1-1010, 76000 Queretaro (Mexico); Mendoza A, E.; Gonzalez, P.R. [ININ, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2003-07-01

    In this work, the thermoluminescent (Tl) signal induced by gamma radiation in zirconia and sulfated zirconia samples embedded in Ptfe pellets is reported and discussed. In this case, samples were obtained through sol-gel method using zirconium n-propoxide and H{sub 2}SO{sub 4} as precursors, and later were subjected to thermal treatment at 600 C to obtain, the tetragonal phase accordingly to X-ray diffraction analysis. Experimental results show that the thermoluminescent glow peak depends on both, the crystalline structure and sulfate concentration. Two maximum peaks were observed located at 147 C and 274 C arising from the electronic transitions. Tl response as a function of the absorbed dose shows a linear increase for a wide of range exposure as well as good stability in time. The high sensitivity, dose linearity and signal stability of this material open the potential possibility to be used for the dosimetry applications. (Author)

  4. On the phototransferred thermoluminescence in MgB4O7:Dy

    International Nuclear Information System (INIS)

    Richmond, R.G.

    1987-01-01

    On exposure to ionizing radiations, the normal traps in MgB 4 0 7 :Dy can be emptied by the readout process only or by annealing at suitable temperatures, leaving the deep traps still intact. Subsequently, it is possible to repopulate the dosimetric peak by illuminating with u.v. light. Charge carriers released from the traps during the second readout give rise to a thermoluminescent output proportional to the ionizing radiation exposure and the u.v. radiant energy. This is called phototransferred thermoluminescence (PTTL). The PTTL method can be utilized for the reassessment of the initial γ-ray exposure. This paper presents the measurements of the intrinsic response of the commercially available MgB 4 0 7 :Dy to u.v. radiation, with a demonstration of its use for γ-ray dose re-estimation using the PTTL technique. (author)

  5. An improved approach to identify irradiated dog feed by electron paramagnetic resonance study and thermoluminescence measurements

    Science.gov (United States)

    Sanyal, Bhaskar; Chawla, S. P.; Sharma, Arun

    2011-05-01

    In the present study, probably for the first time, a detailed analysis of the radiation induced radical species and thermoluminescence measurements of irradiated dog feed are reported. The EPR spectrum of non-irradiated ready-to-eat dog feed was characterized by singlet g=2.0047±0.0003. Irradiated samples exhibited a complex EPR spectrum. During high power (50.0 mW) EPR spectroscopy, a visible change in the shape of the EPR spectrum was observed and characterized by EPR spectrum simulation technique. An axially symmetric anisotropic signal with g║=2.0028 and g┴=1.9976 was identified. However, a negligible change in the matrix of irradiated edible dog chew was observed using EPR spectroscopy. Therefore, thermoluminescence study of the isolated minerals from dog chew was carried out. The composition of the poly-minerals was studied using SEM and EDX analysis and a complete verdict on identification of irradiation is proposed.

  6. Thermoluminescent dosemeter in a X-ray diffractometer; Dosimetria termoluminiscente en un difractometro de rayos X

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza A, D.; Gonzalez M, P.; Falcon B, T. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, Mexico D.F. (Mexico); Castano, V.M. [Instituto de Fisica, UNAM, Laboratorio Juriquilla, A.P. 1-1010, C.P. 76001, Queretaro (Mexico)

    1999-07-01

    In this work it was presented the results obtained of the dosimetry which was realized in a X-ray diffractometer for powders, trademark Siemens D5000, using the thermoluminescent signal generated by the X-rays in the commercial dosemeter TLD-100 of Harshaw, US. In according to the results obtained, the radiation quantity received by an analysed material in the diffractometer, will be proportional to exposure time and it can vary from unities until tenths of grays. These results are very outstanding when are analysed crystalline materials in a diffractometer, for knowing the present crystalline phases, mainly if these are highly sensitive to the ionizing radiation, as it is the case of the thermoluminescent materials. (Author)

  7. Thermoluminescent dosemeters characterization for patient dosimetry in diagnostic radiology preliminary results

    International Nuclear Information System (INIS)

    Castro, William J.; Squair, Peterson L.; Gonzaga, Natalia B.; Nogueira, Maria S.; Silva, Teogenes A. da

    2009-01-01

    The determination of the metrological characteristics of thermoluminescent (TL) dosimeters plays an important role in dosimetry of patients submitted to x-ray examinations for diagnostic purpose. Entrance surface doses can be measured with TL dosimeters to verify the compliance with the diagnostic reference levels. Organ doses can be estimated through TL measurements in an anthropomorphic phantom which it allows the radiation risk assessment. In this work, LiF:Mg,Ti (TLD-100) rod and chip thermoluminescent dosimeters were characterized considering their use for patient dosimetry in computerized tomography and mammography. Preliminary results showed that TL dosimeters have a response reproducibility of 7.8% and 4.8% and homogeneity of 18.4% and 6.5% for rod and chip shapes, respectively. (author)

  8. The initial rise method extended to multiple trapping levels in thermoluminescent materials

    Energy Technology Data Exchange (ETDEWEB)

    Furetta, C. [CICATA-Legaria, Instituto Politecnico Nacional, 11500 Mexico D.F. (Mexico); Guzman, S. [Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, A.P. 70-543, 04510 Mexico D.F. (Mexico); Ruiz, B. [Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, A.P. 70-543, 04510 Mexico D.F. (Mexico); Departamento de Agricultura y Ganaderia, Universidad de Sonora, A.P. 305, 83190 Hermosillo, Sonora (Mexico); Cruz-Zaragoza, E., E-mail: ecruz@nucleares.unam.m [Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, A.P. 70-543, 04510 Mexico D.F. (Mexico)

    2011-02-15

    The well known Initial Rise Method (IR) is commonly used to determine the activation energy when only one glow peak is presented and analysed in the phosphor materials. However, when the glow peak is more complex, a wide peak and some holders appear in the structure. The application of the Initial Rise Method is not valid because multiple trapping levels are considered and then the thermoluminescent analysis becomes difficult to perform. This paper shows the case of a complex glow curve structure as an example and shows that the calculation is also possible using the IR method. The aim of the paper is to extend the well known Initial Rise Method (IR) to the case of multiple trapping levels. The IR method is applied to minerals extracted from Nopal cactus and Oregano spices because the thermoluminescent glow curve's shape suggests a trap distribution instead of a single trapping level.

  9. The initial rise method extended to multiple trapping levels in thermoluminescent materials.

    Science.gov (United States)

    Furetta, C; Guzmán, S; Ruiz, B; Cruz-Zaragoza, E

    2011-02-01

    The well known Initial Rise Method (IR) is commonly used to determine the activation energy when only one glow peak is presented and analysed in the phosphor materials. However, when the glow peak is more complex, a wide peak and some holders appear in the structure. The application of the Initial Rise Method is not valid because multiple trapping levels are considered and then the thermoluminescent analysis becomes difficult to perform. This paper shows the case of a complex glow curve structure as an example and shows that the calculation is also possible using the IR method. The aim of the paper is to extend the well known Initial Rise Method (IR) to the case of multiple trapping levels. The IR method is applied to minerals extracted from Nopal cactus and Oregano spices because the thermoluminescent glow curve's shape suggests a trap distribution instead of a single trapping level. Copyright © 2010 Elsevier Ltd. All rights reserved.

  10. Curve thermoluminescent analysis of ZrO2 doped with nanoparticles and Ag nano fibers

    International Nuclear Information System (INIS)

    Mendoza A, D.; Villa S, G.; Gutierrez W, C.; Perez H, R.; Gonzalez M, P.

    2008-01-01

    This paper presents the results obtained from the analysis of the high temperature thermoluminescence response induced by UV radiation in pure zirconium (ZrO 2 ) and doped with Ag nanoparticles and Ag nano fibers. The zirconium samples were obtained by the sol-gel method and irradiated with a UV lamp for different times. The results showed that the presence of the dopants change the characteristics of the traps associated with the high temperature peak which is located at 230 C for pure zirconium, and that the greater influence is due the presence of Ag nano fibers, inducing a shift to lower temperatures. It also presents the thermoluminescence response as a function of irradiation time. (Author)

  11. Solid thermoluminescent dosemeter of sodium tetraborate and brazilian fluoride sensitive to thermal neutrons

    International Nuclear Information System (INIS)

    Fratin, L.

    1988-01-01

    The techniques of compacting sodium tetraborate and natural fluoride mixtures were studied in this work, with the aim of producing a solid dosimeter sensitive to thermal neutrons. The production procedure involves the vitrification of the sodium tetraborate, the grinding, mixture, cold pressing and the sinterization of the pellets. A special arrangement was built for irradiation where paraffin was used as moderator for neutrons from a 241 Am-Be source. Two different mass ratios of sodium tetraborate and flourite showed a linear thermoluminescent response to the neutron fluence in the range of 1.0 to 7.0 x 10 8 n (sub)tcm -2 . Solid dosimeters, manufactured from natural fluorite and sodium chloride, showed a response to gamma radiation similar to the response of the dosimeters sensitive to neutrons. These dosimeters are need to identify the proportion of thermoluminescent response due to gamma radiation present in a neutron field. (author) [pt

  12. A computerized glow curve analysis (GCA) method for WinREMS thermoluminescent dosimeter data using MATLAB

    International Nuclear Information System (INIS)

    Harvey, John A.; Rodrigues, Miesher L.; Kearfott, Kimberlee J.

    2011-01-01

    A computerized glow curve analysis (GCA) program for handling of thermoluminescence data originating from WinREMS is presented. The MATLAB program fits the glow peaks using the first-order kinetics model. Tested materials are LiF:Mg,Ti, CaF 2 :Dy, CaF 2 :Tm, CaF 2 :Mn, LiF:Mg,Cu,P, and CaSO 4 :Dy, with most having an average figure of merit (FOM) of 1.3% or less, with CaSO 4 :Dy 2.2% or less. Output is a list of fit parameters, peak areas, and graphs for each fit, evaluating each glow curve in 1.5 s or less. - Highlights: → Robust algorithm for performing thermoluminescent dosimeter glow curve analysis. → Written in MATLAB so readily implemented on variety of computers. → Usage of figure of merit demonstrated for six different materials.

  13. Heating rate effect on thermoluminescence glow curves of LiF:Mg,Cu,P+PTFE phosphor

    International Nuclear Information System (INIS)

    Cruz-Zaragoza, E.; Gonzalez, P.R.; Azorin, J.; Furetta, C.

    2011-01-01

    The influence of heating rate on the thermoluminescence (TL) property of LiF:Mg,Cu,P+PTFE was analyzed. The activation energy and the frequency factor as a function of the heating rate were determined. The kinetic parameters and their dependence on the heating rate were evaluated using the sequential quadratic programming glow curve deconvolution (SQPGCD). The results showed that as the heating rate increases, the peak intensity at the maximum (I M ) decreases and shifts to higher temperature; similar behavior of the kinetics parameters was observed. - Highlights: →Heating rate influence on the thermoluminescence (TL) property of LiF:Mg,Cu,P was analyzed. → The kinetic parameters, activation energy and frequency factor were evaluated using the sequential quadratic programming glow curve deconvolution. → The peak intensity at the maximum (I M ) of the glow curves decreases. → Shifts to higher temperature were observed as the heating rate increased. → Similar behavior of the kinetics parameters was noticed.

  14. Heating rate effect on thermoluminescence glow curves of LiF:Mg,Cu,P+PTFE phosphor

    Energy Technology Data Exchange (ETDEWEB)

    Cruz-Zaragoza, E. [Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, A.P. 70-543, Mexico D.F. 04510 (Mexico); Gonzalez, P.R., E-mail: pedro.gonzalez@inin.gob.mx [Instituto Nacional de Investigaciones Nucleares, Carretera Mexico-Toluca S/N, C.P. 52750, Ocoyoacac, Estado de Mexico (Mexico); Azorin, J. [Universidad Autonoma Metropolitana-Iztapalapa, San Rafael Atlixco 186, 09340 Mexico D.F. (Mexico); Furetta, C. [Touro University Rome, Division of Touro College New York, Circne Gianicolense 15-17, 00153 Rome (Italy)

    2011-10-15

    The influence of heating rate on the thermoluminescence (TL) property of LiF:Mg,Cu,P+PTFE was analyzed. The activation energy and the frequency factor as a function of the heating rate were determined. The kinetic parameters and their dependence on the heating rate were evaluated using the sequential quadratic programming glow curve deconvolution (SQPGCD). The results showed that as the heating rate increases, the peak intensity at the maximum (I{sub M}) decreases and shifts to higher temperature; similar behavior of the kinetics parameters was observed. - Highlights: >Heating rate influence on the thermoluminescence (TL) property of LiF:Mg,Cu,P was analyzed. > The kinetic parameters, activation energy and frequency factor were evaluated using the sequential quadratic programming glow curve deconvolution. > The peak intensity at the maximum (I{sub M}) of the glow curves decreases. > Shifts to higher temperature were observed as the heating rate increased. > Similar behavior of the kinetics parameters was noticed.

  15. An improved approach to identify irradiated dog feed by electron paramagnetic resonance study and thermoluminescence measurements

    International Nuclear Information System (INIS)

    Sanyal, Bhaskar; Chawla, S.P.; Sharma, Arun

    2011-01-01

    In the present study, probably for the first time, a detailed analysis of the radiation induced radical species and thermoluminescence measurements of irradiated dog feed are reported. The EPR spectrum of non-irradiated ready-to-eat dog feed was characterized by singlet g=2.0047±0.0003. Irradiated samples exhibited a complex EPR spectrum. During high power (50.0 mW) EPR spectroscopy, a visible change in the shape of the EPR spectrum was observed and characterized by EPR spectrum simulation technique. An axially symmetric anisotropic signal with g || =2.0028 and g perpendicular =1.9976 was identified. However, a negligible change in the matrix of irradiated edible dog chew was observed using EPR spectroscopy. Therefore, thermoluminescence study of the isolated minerals from dog chew was carried out. The composition of the poly-minerals was studied using SEM and EDX analysis and a complete verdict on identification of irradiation is proposed.

  16. Thermo-transferred thermoluminescence (TTTl) in potassium-yttrium double fluoride doped with terbium

    Energy Technology Data Exchange (ETDEWEB)

    Gallegos, A.; Rivera, T.; Diaz G, J. A. [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Legaria 694, Col. Irrigacion, 11500 Mexico D. F. (Mexico); Azorin, J. [Universidad Autonoma Metropolitana, Unidad Iztapalapa, San Rafael Atlixco No. 186, Col. Vicentina, 09340 Mexico D. F. (Mexico); Azorin, J. C. [Universidad de Guanajuato, Division de Ciencias e Ingenierias-Campus Leon, Lomas del Bosque No. 103, Col. Lomas del Campestre, 37000 Leon, Guanajuato (Mexico); Licona, R.; Rivas, F.; Hernandez C, G. [Benemerita Universidad Autonoma de Puebla, Facultad de Ciencias Quimicas, 14 Sur y San Claudio, Ciudad Universitaria, Puebla de Zaragoza, Puebla (Mexico); Khaidukov, N. [Institute of General and Inorganic Chemistry, Lenin SK 11 Prospect 31, Moscow 117907 (Russian Federation)

    2011-02-15

    This paper presents results of studying the thermo-transferred thermoluminescence (TTTl) phenomenon in potassium-yttrium double fluoride doped with terbium (K{sub 2}YF{sub 5:}Tb) at different impurity concentrations (0.8%, 0.95% and 0.99%). Previously to study the TTTl phenomenon, structural characterization and chemical composition of the materials were determined. The structural studies were conducted using a scanning electron microscope; meanwhile, chemical composition was analyzed using energy dispersive X-ray spectroscopy. Thermoluminescence kinetics was studied irradiating the samples with {sup 137}Cs gamma rays as well as with {sup 90}Sr/{sup 90}Y beta rays, analyzing the glow curves by the deconvolution method for obtaining the kinetic parameters. (Author)

  17. Desenvolvimento puberal em meninas tratadas de LLA

    Directory of Open Access Journals (Sweden)

    Monteiro I.M.M.

    1998-01-01

    Full Text Available OBJETIVO: Com o objetivo de avaliar o desenvolvimento puberal após o tratamento de leucemia linfóide aguda (LLA na infância, foi realizado um estudo retrospectivo, em meninas tratadas de janeiro de 1980 a janeiro de 1991, no Centro de Investigações Hematológicas "Dr. Domingos A. Boldrini", em Campinas-SP. CASUÍSTICA E MÉTODO: Foram selecionadas 42 meninas, tratadas antes da puberdade com quimioterapia sistêmica e intratecal e radioterapia cranial, utilizando doses de 18 ou 24 Grays (Gy. RESULTADOS: As idades médias da telarca, pubarca e menarca foram inferiores às do grupo-controle, embora com significância estatística apenas para a idade da telarca. Não houve diferenças entre os grupos tratados com 18 ou 24Gy. As meninas tratadas antes dos cinco anos de idade apresentaram idade média da menarca estatisticamente inferior àquelas tratadas após cinco anos e em relação ao grupo-controle. CONCLUSÃO: Os resultados mostraram que o desenvolvimento puberal em meninas tratadas de LLA na infância foi mais precoce que o de meninas saudáveis.

  18. Charles Darwin: um observador do desenvolvimento humano

    Directory of Open Access Journals (Sweden)

    Eloisa Helena Rubello Valler Celeri

    2010-12-01

    Full Text Available Os autores traduzem, pela primeira vez para o português, o artigo de Charles Darwin "A Biographical Sketch of an Infant", publicado no periódico Mind em julho de 1877. Utilizando anotações de observações do desenvolvimento de seus filhos, especialmente de seu filho mais velho William Erasmus (Doddy, Darwin descreve e estuda, a partir de seu enfoque naturalista, o filhote humano, narrando os primeiros indicativos comportamentais de emoções tais como raiva e medo, curiosidade e senso moral, o brincar e o prazer envolvido nesta atividade, a capacidade de imitação e os primeiros indícios daquilo que hoje conhecemos como "teoria da mente". Colocando-se questões sobre as capacidades do bebê, como eles aprendem e como se comunicam e levantando hipóteses sobre possíveis significados de certos comportamentos, questões ainda hoje fundamentais para o estudo do desenvolvimento humano, Darwin mostra-se também um pioneiro no estudo do bebê e da criança pequena, numa época na qual as capacidades dos bebês eram extremamente subestimadas e desconsideradas.

  19. Particle detectors

    CERN Document Server

    Hilke, Hans Jürgen; Joram, Christian; CERN. Geneva

    1991-01-01

    Lecture 5: Detector characteristics: ALEPH Experiment cut through the devices and events - Discuss the principles of the main techniques applied to particle detection ( including front-end electronics), the construction and performance of some of the devices presently in operartion and a few ideas on the future performance. Lecture 4-pt. b Following the Scintillators. Lecture 4-pt. a : Scintillators - Used for: -Timing (TOF, Trigger) - Energy Measurement (Calorimeters) - Tracking (Fibres) Basic scintillation processes- Inorganic Scintillators - Organic Scintil - Discuss the principles of the main techniques applied to particle detection ( including front-end electronics), the construction and performance of some of the devices presently in operation and a fiew ideas on future developpement session 3 - part. b Following Calorimeters lecture 3-pt. a Calorimeters - determine energy E by total absorption of charged or neutral particles - fraction of E is transformed into measurable quantities - try to acheive sig...

  20. Smoke detectors

    International Nuclear Information System (INIS)

    Bryant, J.

    1979-01-01

    An ionization smoke detector consisting of two electrodes defining an ionization chamber permitting entry of smoke, a radioactive source to ionize gas in the chamber and a potential difference applied across the first and second electrodes to cause an ion current to flow is described. The current is affected by entry of smoke. An auxiliary electrode is positioned in the ionization chamber between the first and second electrodes, and it is arranged to maintain or create a potential difference between the first electrode and the auxiliary electrode. The auxiliary electrode may be used for testing or for adjustment of sensitivity. A collector electrode divides the chamber into two regions with the auxiliary electrode in the outer sensing region. (U.K.)

  1. Dating the Morasko meteorite fall by natural thermoluminescence of the fusion crust

    Directory of Open Access Journals (Sweden)

    Fedorowicz Stanisław

    2016-09-01

    Full Text Available The date of fall of the Morasko iron meteorite was determined by means of thermoluminescence measurements of the fusion crust and related local materials. Three small pieces, commonly referred to as ‘shrapnel’, were used. The results obtained are 4.5-5.0 ka, which is in good agreement with previous estimates of 4-6 ka on the basis of radiometric, do-simetric and palynological methods.

  2. Application of numerical methods in spectroscopy : fitting of the curve of thermoluminescence

    International Nuclear Information System (INIS)

    RANDRIAMANALINA, S.

    1999-01-01

    The method of non linear least squares is one of the mathematical tools widely employed in spectroscopy, it is used for the determination of parameters of a model. In other hand, the spline function is among fitting functions that introduce the smallest error. It is used for the calculation of the area under the curve. We present an application of these methods, with the details of the corresponding algorithms, to the fitting of the thermoluminescence curve. [fr

  3. Thermoluminescence as a complementary technique for the toxicological evaluation of chemicals in photosynthetic organisms

    Energy Technology Data Exchange (ETDEWEB)

    Repetto, Guillermo, E-mail: grepkuh@upo.es [Departamento de Biología Molecular e Ingeniería Bioquímica, Área de Toxicología, Universidad Pablo de Olavide, Carretera de Utrera km. 1, 41013 Seville (Spain); Zurita, Jorge L. [Departamento de Biología Molecular e Ingeniería Bioquímica, Área de Toxicología, Universidad Pablo de Olavide, Carretera de Utrera km. 1, 41013 Seville (Spain); Roncel, Mercedes; Ortega, José M. [Instituto de Bioquímica Vegetal y Fotosíntesis, Universidad de Sevilla-CSIC, Américo Vespucio 49, 41092 Seville (Spain)

    2015-01-15

    Highlights: • There are very few toxicological applications of thermoluminescence. • It is a luminescence emission induced by heating the sample in the dark. • It is useful for study the photosystem II function and the level of lipid peroxidation. - Abstract: Thermoluminescence is a simple technique very useful for studying electron transfer reactions on photosystem II (standard thermoluminescence) or the level of lipid peroxidation in membranes (high temperature thermoluminescence) in photosynthetic organisms. Both techniques were used to investigate the effects produced on Chlorella vulgaris cells by six compounds: the chemical intermediates bromobenzene and diethanolamine, the antioxidant propyl gallate, the semiconductor indium nitrate, the pesticide sodium monofluoroacetate and the antimalarial drug chloroquine. Electron transfer activity of the photosystem II significantly decreased after the exposure of Chlorella cells to all the six chemicals used. Lipid peroxidation was slightly decreased by the antioxidant propyl gallate, not changed by indium nitrate and very potently stimulated by diethanolamine, chloroquine, sodium monofluoroacetate and bromobenzene. For five of the chemicals studied (not bromobenzene) there is a very good correlation between the cytotoxic effects in Chlorella cells measured by the algal growth inhibition test, and the inhibition of photosystem II activity. The results suggest that one very important effect of these chemicals in Chlorella cells is the inhibition of photosynthetic metabolism by the blocking of photosystem II functionality. In the case of sodium monofluoroacetate, diethanolamine and chloroquine this inhibition seems to be related with the induction of high level of lipid peroxidation in cells that may alter the stability of photosystem II. The results obtained by both techniques supply information that can be used as a supplement to the growth inhibition test and allows a more complete assessment of the effects of

  4. Evaluation of fatigue property of PET tyre cord and rubber by using thermoluminescence

    International Nuclear Information System (INIS)

    Liangbao Liu; Sumita, Masao; Miyasaka, Keizo

    1988-01-01

    Glow curves have been measured at different heating rates for samples of polyethylene terephthalate (PET) tyre cords and tyre rubber before and after fatigue. From these measurements values of the thermoluminescence activation energy (E) and frequency factor (S) have been derived. E and, most strikingly, S, both increased during fatigue. It is suggested that the changes observed in E and S offer a new approach to the study of fatigue resistance in organic polymers. (U.K.)

  5. Thermoluminescence dating of CaCO3 nodules from buried soil of the lower Narmada Valley

    International Nuclear Information System (INIS)

    Nambi, K.S.V.; Hegde, K.T.M.

    1982-01-01

    Calcium carbonate nodules excavated at an archaeological site in Lower Narmada River Valley have been dated by the thermoluminescence technique. Tiny, sensitive TL dosimeters using natural CaF 2 as the phosphor, were employed to evaluate the natural radiation levels at the excavation site over a period of a year. The estimated TL age value is 22890 yrs B.P. with an uncertainty of about +/- 8%. The reported 14 C age of these nodules is 22452 +/- 550 years B.P

  6. Thermoluminescence dating studies at Gua Tok Long, Gunung Senyum, Temerloh, Pahang

    International Nuclear Information System (INIS)

    Rosli Mahat

    2004-01-01

    The paper discussed the thermoluminescence dating studies carried-out by the researchers from Physics Department, University Malaya. One of these dating studies was done at a cave of the mountain, Gua Tok Long, Gunung Senyum, Temerloh, Pahang, Malaysia. The result presents a straight line of Age vs Height graph. It shows the particulates and dirts of the cave atmosphere landed at constant rate on the cave floor without an erosion

  7. A new dating method by thermoluminescence of carved megalithic stone building

    International Nuclear Information System (INIS)

    Pedro, G.

    1994-01-01

    A first attempt to develop a new Thermoluminescence (TL) dating method of carved megalithic limestone stones from 'Mycenae' and 'Helleniko' buildings, Peloponnese, Greece, is shown to be encouraging. Based upon the principle of optical bleaching, total TL doses have been measured between 11-17 Gy, while the age of the Mycenean wall, c. 1280 BC, is compatible with the estimated by the new method. (author). 11 refs., 4 figs

  8. Effect of the interaction among traps on the shape of thermoluminescence glow curves

    International Nuclear Information System (INIS)

    Marcazzo, J.; Santiago, M.; Spano, F.; Lester, M.; Ortega, F.; Molina, P.; Caselli, E.

    2007-01-01

    The effect of the interaction among traps on the structure of thermoluminescence glow curves has been investigated by generating numerically simulated glow curves for a wide range of trap parameters. The results reported in this paper provide useful insights which assist in the analysis of experimental glow curves. The most important result shows that it is incorrect to assume beforehand that each peak is related to a specific trapping state. The validity of the quasiequilibrium approximation is briefly discussed

  9. Determination of the dose index in computerized tomography using thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Azorin, J.C.; Calderon, A.; Azorin, J.

    2004-01-01

    In this work the obtained results of the determination of the dose index are presented in thorax studies in computed tomography and helical tomography carried out in Mexico using thermoluminescent dosemeters of LiF: Mg,Cu,P + Ptfe developed and manufactured in our country. The results showed that under similar conditions of irradiation and operation (pitch = 1), significant differences don't exist among the doses absorbed measures in the phantom due to the two types of used tomographs. (Author)

  10. Dating of the archaeological site 'El Tigre' by the thermoluminescent method

    International Nuclear Information System (INIS)

    Portilla, R. De la; Gonzalez, P.R.; Mendoza, D.; Vargas, E.; Ramirez, A.

    2007-01-01

    Full text: The dating of pre hispanic pottery, is supported by techniques such as stratigraphy, typology, in physical and chemical procedures, as the analysis of 14 C and the thermoluminescence (TL). The last one permits us obtain absolute dating of archaeological pottery with an acceptable precision. In this work we apply the applied the thermoluminescent technique to verify the age of the Pre-Classic and Classic Terminal periods proposed for the archaeological site 'El Tigre', Campeche. The samples were obtained during a work period and the radiation of the ground of background (emitted by the ground), as well as the contribution of the cosmic radiation was measured with thermoluminescent dosemeters of LiF: Mg,Cu,P + PTFE, put in the sample zone. The preliminary results indicate that not all the analyzed samples can be dated. The viability of the dating of the samples is discussed based on the fact and function of the presence of certain crystalline phases such as calcite and quartz. The discussion is complemented emphsizing the importance of handling the conditions of handling of samples. (Author)

  11. High dose thermoluminescence dosimetry performance of Sol-gel synthesized TiO{sub 2} phosphors

    Energy Technology Data Exchange (ETDEWEB)

    Salas J, Ch. J.; Cruz V, C. [Universidad de Sonora, Departamento de Investigacion en Polimeros y Materiales, Apdo. Postal 130, 83000 Hermosillo, Sonora (Mexico); Castillo U, D. M.; Flores M, K. [Universidad de Sonora, Departamento de Ciencias Quimico Biologicas, Apdo. Postal 130, 83000 Hermosillo, Sonora (Mexico); Bernal, R. [Universidad de Sonora, Departamento de Investigacion en Fisica, Apdo. Postal 5-088, 83190 Hermosillo, Sonora (Mexico); Castano, V. M., E-mail: castillouzeta@gmail.com [UNAM, Instituto de Fisica, Centro de Fisica Aplicada y Tecnologia Avanzada, Apdo. Postal 1-1010, Queretaro, Qro. (Mexico)

    2015-10-15

    Full text: TiO{sub 2} is a ceramic material with many applications due to their different crystalline phases (rutile, anatase and brookite). It has attracted attention in several fields because their high mechanical strength, chemical stability and ion-conducting properties. Moreover, in recent years, some research groups gained interest in the thermoluminescence features of TiO{sub 2} concerning their potential use as thermoluminescence dosimeter. In this work, we present experimental results obtained in the first stage of a long-term research project focused in the synthesis of TiO{sub 2} phosphors for dosimetric applications. The thermoluminescent characterization of samples was carried out after being exposed to beta particle irradiation. TiO{sub 2} was prepared by alkoxide sol-gel route using titanium tetrabutoxide as precursor, ethanol, water and ammonia as catalyst. Pellet-shaped samples were annealed at 700 degrees C for 6 h in air atmosphere followed by slow cooling, and then were exposed to radiation doses from 25 to 400 Gy. The glow curves display maxima located at 103 and 238 degrees C when a 5 C/s heating rate is used. From the experimental results here presented, we conclude that TiO{sub 2} is a promising material to develop high dose Tl dosimeters. (Author)

  12. Synthesis, characterization and thermoluminescence studies of (ZnS)1-x(MnTe)xnanophosphors.

    Science.gov (United States)

    Pateria, Deepti; Baghel, R N; Bisen, D P; Jha, Piyush; Chandra, V K; Chandra, B P

    2017-05-01

    The present paper reports the thermoluminescence (TL) of (ZnS) 1-x (MnTe) x nanophosphors that were prepared by a wet chemical synthesis method. The structure investigated by X-ray diffraction patterns confirms the formation of a sphalerite phase whose space group was found to be F 4¯3m. From XRD, TEM and SEM analyses the average sizes of the particles were found to be 12 nm, 11 nm and 15 nm, respectively. Initially the TL intensity increased with increasing values of x because the number of luminescence centres increased; however, for higher values of x the TL intensity decreased because of the concentration quenching. Thus the TL, mechanoluminescence and photoluminescence intensities are optimum for a particular value of x, that is for x = 0.05. Thermoluminescence of the (ZnS) 1-x (MnTe) x nanophosphor has not been reported previously. There were two peaks seen in the thermoluminescence glow curves in which the first peak lay at 105-100 °C and the second peak lay at 183.5-178.5 °C. The activation energies for the first and second peaks were found to be 0.45 eV and 0.75 eV, respectively. Copyright © 2016 John Wiley & Sons, Ltd.

  13. Thermoluminescent dosimetry of beta radiations of 90 Sr/ 90 Y using amorphous ZrO2

    International Nuclear Information System (INIS)

    Rivera M, T.; Olvera T, L.; Azorin N, J.; Barrera R, M.; Soto E, A.M.

    2005-01-01

    In this work the results of studying the thermoluminescent properties (Tl) of the zirconium oxide in its amorphous state (ZrO 2 -a) before beta radiations of 90 Sr/ 90 Y are presented. The amorphous powders of the zirconium oxide were synthesized by means of the sol-gel technique. The sol-gel process using alkoxides like precursors, is an efficient method to prepare a matrix of zirconium oxide by hydrolysis - condensation of the precursor to form chains of Zr-H 3 and Zr-O 2 . One of the advantages of this technique is the obtention of gels at low temperatures with very high purity and homogeneity. The powders were characterized by means of thermal analysis and by X-ray diffraction. The powders of ZrO 2 -a, previously irradiated with beta particles of 90 Sr/ 90 Y, presented a thermoluminescent curve with two peaks at 150 and 257 C. The dissipation of the information of the one ZrO 2 -a was of 40% the first 2 hours remaining constant the information for the following 30 days. The reproducibility of the information was of ± 2.5% in standard deviation. The studied characteristics allow to propose to the amorphous zirconium oxide as thermoluminescent dosemeter for the detection of beta radiation. (Author)

  14. Thermoluminescent dosimetry of beta radiations of 90 Sr/ 90 Y using ZrO2: Eu

    International Nuclear Information System (INIS)

    Olvera T, L.; Azorin N, J.; Barrera S, M.; Soto E, A.M.; Rivera M, T.

    2005-01-01

    In this work the results of studying the thermoluminescent properties (TL) of the doped zirconium oxide with europium (ZrO 2 : Eu 3+ ) before beta radiations of 90 Sr/ 90 Y are presented. The powders of ZrO 2 : Eu 3+ were obtained by means of the sol-gel technique and they were characterized by means of thermal analysis and by X-ray diffraction. The powders of ZrO 2 : Eu 3+ , previously irradiated with beta particles of 90 Sr/ 90 Y, presented a thermoluminescent curve with two peaks at 204 and 292 C respectively. The TL response of the ZrO 2 : Eu 3+ as function of the absorbed dose was lineal from 2 Gy up to 90 Gy. The fading of the information of the ZrO 2 : Eu 3+ was of 10% the first 2 hours remaining almost constant the information by the following 30 days. The ZrO 2 doped with the (Eu 3+ ) ion it was found more sensitive to the beta radiation that the one of zirconium oxide without doping (ZrO 2 ) obtained by the same method. Those studied characteristics allow to propose to the doped zirconium oxide with europium like thermoluminescent dosemeter for the detection of the beta radiation. (Author)

  15. Thermoluminescent dosimetry of ionizing radiations using ZrO2 prepared at low temperatures

    International Nuclear Information System (INIS)

    Rivera M, T.; Diaz G, J.A.I.; Olvera T, L.; Azorin N, J.; Barrera S, M.; Soto E, A.M.

    2005-01-01

    The thermoluminescent dosimetry (TLD) it is a versatile tool for an evaluation of dose of ionizing radiation. A great variety of ceramic materials and their different physical forms allow a determination of the ionizing radiation in a wide dose interval. In this work the results of studying those thermoluminescent characteristics (TL) of the zirconium oxide obtained by means of the sol-gel technique to low temperatures are presented. To these temperatures the material was obtained in its amorphous state (ZrO 2 -a). The structural characteristics of ZrO 2 -a they were obtained by means of X-ray diffraction. The TL characteristics studied were: TL curve, reproducibility of the TL signal and the fading of the information. The powders of ZrO 2 -a, previously irradiated with beta particles of 90 Sr/ 90 Y, they presented a thermoluminescent curve with two peaks at 150 and 260 C. The fading of the information of the one ZrO 2 -a it was of 20% during the first two hours starting from this time there was one lost of information of 5% to the finish of the 30 days. The reproducibility of the information was of ± 2.5% in standard deviation. (Author)

  16. An integral equation method for discrete and continuous distribution of centres in thermoluminescence kinetics

    International Nuclear Information System (INIS)

    Kantorovich, L.N.; Fogel, G.M.; Gotlib, V.I.

    1990-01-01

    Thermoluminescence kinetics is discussed within the framework of a band model containing an arbitrary number of types of recombination and trapping centres at an arbitrary correlation of all centre parameters. It is shown that the initial system of kinetic equations is reduced to an equivalent system consisting of two integro-differential equations which permit one to perform an accurate generalisation, in the case of a continuous centre distribution, to their parameters for the description of irradiation and thermoluminescence, taking into account charge carrier redistribution to both types of centre. In addition, if only one electron (hole) channel is taken into account, only one integro-differential equation is obtained. On the basis of this equation a precise algebraic equation is obtained for calculation of the area of an arbitrary part of the thermoluminescence curve (TLC), consisting of one or several peaks, which slightly overlap with other peaks. It is shown that at doses which are less than the saturation dose, when the centres are not completely filled by the charge carriers, the dose dependences of such a part of the TLC may have a non-linear character at a simultaneous linear dependence of the area of the whole TLC. At doses which are greater than the saturation dose, the dose dependences of the area of the whole TLC, as well as of its separate parts, undergo breaks at the saturation doses. (author)

  17. Dosimetric evaluation of thermoluminescent LiF:Mg,Ti and CaSO4 :Dy dosimeters and LiF microdosimeters for application in in vivo dosimetry of clinical electron beams

    International Nuclear Information System (INIS)

    Bravim, Amanda; Campos, Leticia L.

    2009-01-01

    The verification of the patient dose has been recommended to improve the quality of radiotherapy treatment by various organizations such as AAPM (American Association of Physicists in Medicine) and ESTRO (European Society of Therapeutic Radiology and Oncology). The in vivo dosimetry has become an important part in the program of quality assurance (QA) in the departments of radiotherapy and has proved very useful in determining the dose applied to a particular patient, as well as detection of various types of errors in the dose process application. Thermoluminescent dosimeters (TLD) play an important role in radiation dosimetry and present advantages that make them useful for in vivo dosimetry in patients. This paper aims to evaluate the performance of LiF microdosimeters and LiF: Mg,Ti and CaSO 4 : Dy dosimeters in 60 Co gamma field and select the detectors groups which present TL response with sensitivity and reproducibility better than ± 5%. It is expected a standardized method of employing the thermoluminescent dosimetry technique and development of a dosimetric system in accordance with the international recommendations. (author)

  18. CLIC Detector Power Requirements

    CERN Document Server

    Gaddi, A

    2013-01-01

    An estimate for the CLIC detector power requirements is outlined starting from the available data on power consumptions of the four LHC experiments and considering the differences between a typical LHC Detector (CMS) and the CLIC baseline detector concept. In particular the impact of the power pulsing scheme for the CLIC Detector electronics on the overall detector consumption is considered. The document will be updated with the requirements of the sub-detector electronics once they are more defined.

  19. Comparing of the yield curve of the pediatric X-ray equipment using thermoluminescent dosimeters and cylindrical ionization chamber; Comparacao da curva de rendimento de um aparelho de raios X pediatrico utilizando dosimetros termoluminescentes e camara de ionizacao cilindrica

    Energy Technology Data Exchange (ETDEWEB)

    Filipov, Danielle, E-mail: dfilipov@utfpr.edu.br [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil); Schelin, Hugo R., E-mail: ledesmaiorgealberto@gmail.com [Instituto de Pesquisa Pele Pequeno Principe, Curitiba, PR (Brazil); Tilly Junior, Joao G., E-mail: joao.tilly@derax.com.br [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil). Hospital de Clinicas

    2014-07-01

    The determination of the yield curve of a radiographic equipment should be realized once a year, or when the unit be serviced. Besides being a requirement of ANVISA, through this test is possible to determine the incident air kerma (at a given point in the center of the beam) - INAK. Based on these concepts, the main objective of this work is the comparison of yield curves of the pediatric X-ray apparatus using two different detectors: one cylindrical ionization chamber and thermoluminescent dosimeters type LiF: Mg, Cu, P, as per protocol RLA / 9/057 IAEA. Then the equation of the yield curve (generated by each detector) was used to determine the INAK of 10 pediatric examinations, performed on this equipment. After the process of calibration of both detectors, they were placed side by side at a focus of the tube equipment for determining the performance of the same curve. Finally, using the curves generated by two detectors, INAK values of the 10 tests were calculated (from the kVp values, and mAs focus-patient of each exams), generating difference values at most 5%. As a conclusion, it can be said that the TLD lithium fluoride doped with Mg, Cu and P and the cylindrical ionization chambers may be used satisfactorily to determine the yield curve, whether as quality control or dosimetry.

  20. Calibration of detector efficiency of neutron detector

    International Nuclear Information System (INIS)

    Guo Hongsheng; He Xijun; Xu Rongkun; Peng Taiping

    2001-01-01

    BF 3 neutron detector has been set up. Detector efficiency is calibrated by associated particle technique. It is about 3.17 x 10 -4 (1 +- 18%). Neutron yield of neutron generator per pulse (10 7 /pulse) is measured by using the detector

  1. Thermoluminescent response of dosemeters TLD-100 exposed to distinct baker protocols, irradiation and reading

    International Nuclear Information System (INIS)

    Estrada E, D.

    2002-01-01

    The interest that motivated the realization of this work is the opposing discrepancy among the values of the efficiency thermoluminescent of heavy charged particles (PCP) regarding gamma radiation (η PCP , γ) reported in different works and gathered recently for Horowitz (Ho 01). The measures of relative thermoluminescent efficiency have importance in relation to the dosimetry associated to medical therapy with heavy charged particle. The measurement of η PCP , γ depends of multiple experimental factors. To understand this dependence it was quantified the effect of using different procedures experimental in the estimate of the relative thermoluminescent efficiency of dosemeters TLD-100 (LiF: Ti; Mg) for protons of 3 MeV regarding gamma rays of 60 Co (η PCP , γ), varying the lot, the presentation, the one baked and the team reader. When was used the same global procedure values they were obtained for (η PCP , γ) inside the interval [0.30, 0.58] for the peak 5 and [0.35, 0.76] for the total thermoluminescent signal (Tl). At the use different equipment, baked and lot are obtained maximum differences of 30%, 12% and 6% respectively in the values of (η PCP , γ) for the peak 5, and 25%, 28% and 7% for the total Tl signal. The changes more significant of 36% and 44% for peak 5 and total signal respectively are obtained when changing the presentation of the dosemeter. As a complementary investigation it was studied the distribution of the Tl signal of each peak in the deconvolution of the curve of brightness with regard to the total signal in exposed dosemeters to high fluence of protons (1x10 10 p/cm 2 ) varying the experimental protocol. It was found that the distribution of the Tl signal has a difference of the order of 5% when changing the used reading team. It was observed that the contribution of the peak 5 regarding the total signal are preserved when changing baked and that it results to be 8% greater for the presentation in dosemeters of 1 x 1 x 1 mm 3

  2. MUON DETECTOR

    CERN Multimedia

    F. Gasparini

    DT As announced in the previous Bulletin MU DT completed the installation of the vertical chambers of barrel wheels 0, +1 and +2. 242 DT and RPC stations are now installed in the negative barrel wheels. The missing 8 (4 in YB-1 and 4 in YB-2) chambers can be installed only after the lowering of the two wheels into the UX cavern, which is planned for the last quarter of the year. Cabling on the surface of the negative wheels was finished in May after some difficulties with RPC cables. The next step was to begin the final commissioning of the wheels with the final trigger and readout electronics. Priority was giv¬en to YB0 in order to check everything before the chambers were covered by cables and services of the inner detectors. Commissioning is not easy since it requires both activity on the central and positive wheels underground, as well as on the negative wheels still on the surface. The DT community is requested to commission the negative wheels on surface to cope with a possible lack of time a...

  3. DESENVOLVIMENTO PROFISSIONAL EM COMUNIDADES DE APRENDIZAGEM DOCENTE

    Directory of Open Access Journals (Sweden)

    Vanessa Moreira Crecci

    2018-01-01

    Full Text Available RESUMO: Neste artigo, temos por objetivo relacionar projeções de desenvolvimento profissional e de profissionalidade a diferentes tipos de comunidades de aprendizagem docente. Para tanto, realizamos uma discussão a partir da descrição de diferentes modos de organização dessas comunidades. Em seguida, discorremos sobre as características subjacentes às comunidades fronteiriças, nas quais pesquisadores, professores e futuros professores trabalham de modo colaborativo, sem a regulação da universidade ou da escola. Ao final desta discussão, conclui-se que, por mais que as metodologias sejam aparentemente inovadoras, tornam-se necessárias avaliações dos processos formativos e reflexões cuidadosas sobre os aspectos subjacentes às comunidades de aprendizagem docente.

  4. As Parcerias para o Desenvolvimento Produtivo em saúde na nova agenda de desenvolvimento nacional

    Directory of Open Access Journals (Sweden)

    Laís Silveira Costa

    Full Text Available RESUMO Ao refletir seu caráter sistêmico, as Parcerias para o Desenvolvimento Produtivo (PDP representam uma inflexão na política de saúde e constituem o principal instrumento de ação pública da comunidade de política desenvolvimentista de saúde. Considerando a relevância da saúde para uma trajetória de desenvolvimento nacional que alia competitividade econômica e inclusão social, este artigo visa analisar os elementos político-institucionais que condicionam o desenvolvimento nacional na política de saúde, com destaque para as PDP. Para tanto, utiliza o arcabouço teórico da análise cognitiva das políticas públicas visando identificar como as instituições orientam suas estratégias e as preferências dos atores, e como influenciam os resultados da ação pública.

  5. Rapid assessment of accidental exposures (RACE) with MCP-N (LiF:Mg,Cu,P) detectors

    International Nuclear Information System (INIS)

    Budzanowski, M.; Bilski, P.; Olko, P.; Saez-Vergara, J.C.; Gomes-Ros, J.M.

    1998-01-01

    The system is based on a new generation of ultra-sensitive thermoluminescent dosemeters and is able to monitor environmental radiation doses at a large number of locations within few days and to perform rapid (24 - 48 hours) in situ dose assessment in the event of any nuclear or radiation accident. Technical specifications of the instrumentation and procedures of the system are given. The linearity of the detector response for doses within the range of 1 μGy to 1 Gy is better than 2%. All the detectors investigated demonstrated a good stability in long-term exposure. The detectors are fully comparable with active detectors in short-term and daily routine dose rate measurements. (M.D.)

  6. Semiconductor scintillator detector for gamma radiation; Detector cintilador semicondutor para radiacao gama

    Energy Technology Data Exchange (ETDEWEB)

    Laan, F.T.V. der; Borges, V.; Zabadal, J.R.S., E-mail: ftvdl@ufrgs.br, E-mail: borges@ufrgs.br, E-mail: jorge.zabadal@ufrgs.br [Universidade Federal do Rio Grande do Sul (GENUC/DEMEC/UFRGS), Porto Alegre, RS (Brazil). Grupo de Estudos Nucleares. Departamento de Engenharia Mecanica

    2015-07-01

    Nowadays the devices employed to evaluate individual radiation exposition are based on dosimetric films and thermoluminescent crystals, whose measurements must be processed in specific transductors. Hence, these devices carry out indirect measurements. Although a new generation of detectors based on semiconductors which are employed in EPD's (Electronic Personal Dosemeters) being yet available, it high producing costs and large dimensions prevents the application in personal dosimetry. Recent research works reports the development of new detection devices based on photovoltaic PIN diodes, which were successfully employed for detecting and monitoring exposition to X rays. In this work, we step forward by coupling a 2mm anthracene scintillator NE1, which converts the high energy radiation in visible light, generating a Strong signal which allows dispensing the use of photomultipliers. A low gain high performance amplifier and a digital acquisition device are employed to measure instantaneous and cumulative doses for energies ranging from X rays to Gamma radiation up to 2 MeV. One of the most important features of the PIN diode relies in the fact that it can be employed as a detector for ionization radiation, since it requires a small energy amount for releasing electrons. Since the photodiode does not amplify the corresponding photon current, it must be coupled to a low gain amplifier. Therefore, the new sensor works as a scintillator coupled with a photodiode PIN. Preliminary experiments are being performed with this sensor, showing good results for a wide range of energy spectrum. (author)

  7. Detector simulation needs for detector designers

    Energy Technology Data Exchange (ETDEWEB)

    Hanson, G.G.

    1987-11-01

    Computer simulation of the components of SSC detectors and of the complete detectors will be very important for the designs of the detectors. The ratio of events from interesting physics to events from background processes is very low, so detailed understanding of detector response to the backgrounds is needed. Any large detector for the SSC will be very complex and expensive and every effort must be made to design detectors which will have excellent performance and will not have to undergo major rebuilding. Some areas in which computer simulation is particularly needed are pattern recognition in tracking detectors and development of shower simulation code which can be trusted as an aid in the design and optimization of calorimeters, including their electron identification performance. Existing codes require too much computer time to be practical and need to be compared with test beam data at energies of several hundred GeV. Computer simulation of the processing of the data, including electronics response to the signals from the detector components, processing of the data by microprocessors on the detector, the trigger, and data acquisition will be required. In this report we discuss the detector simulation needs for detector designers.

  8. Measurement of the dose by dispersed radiation in a lineal accelerator using thermoluminescent dosimeters of CaSO4:Dy

    International Nuclear Information System (INIS)

    Chavez C, N.; Torijano, E.; Azorin, J.; Herrera, A.

    2014-08-01

    The thermoluminescence (Tl) is based on the principle of the luminescent in a material when is heated below their incandescence temperature. Is a technique very used in dosimetry that is based on the property that have most of the crystalline materials regarding the storage of the energy that they absorb when are exposed to the ionizing radiations. When this material has been irradiated previously, the radioactive energy that contains is liberated in form of light. In general, the principles that govern the thermoluminescence are in essence the same of those responsible for all the luminescent processes and, this way, the thermoluminescence is one of the processes that are part of the luminescence phenomenon. For this work, the dispersed radiation was measured in the therapy area of the lineal accelerator of medical use type Elekta, using thermoluminescent dosimeters of CaSO 4 :Dy + Ptfe developed and elaborated in the Universidad Autonoma Metropolitana, Unidad Iztapalapa. With the dosimeters already characterized and calibrated, we proceeded to measure the dispersed radiation being a patient in treatment. The results showed values for the dispersed radiation the order of a third of the dose received by the patient on the treatment table at 30 cm of the direct beam and the order of a hundredth in the control area (4 m of the direct beam, approximately). The conclusion is that the thermoluminescent dosimeters of CaSO 4 : Dy + Ptfe are appropriate to measure dispersed radiation dose in radiotherapy. (author)

  9. The GRANDE detector

    International Nuclear Information System (INIS)

    Adams, A.; Bond, R.; Coleman, L.; Rollefson, A.; Wold, D.; Bratton, C.B.; Gurr, H.; Kropp, W.; Nelson, M.; Price, L.R.; Reines, F.; Schultz, J.; Sobel, H.; Svoboda, R.; Yodh, G.; Burnett, T.; Chaloupka, V.; Wilkes, R.J.; Cherry, M.; Ellison, S.B.; Guzik, T.G.; Wefel, J.; Gaidos, J.; Loeffler, F.; Sembroski, G.; Wilson, C.; Goodman, J.; Haines, T.J.; Kielczewska, D.; Lane, C.; Steinberg, R.; Lieber, M.; Nagle, D.; Potter, M.; Tripp, R.

    1990-01-01

    In this paper we present a detector facility which meets the requirements outlined above for a next-generation instrument. GRANDE (Gamma Ray and Neutrino DEtector) is an imaging, water Cerenkov detector, which combines in one facility an extensive air shower array and a high-energy neutrino detector. (orig.)

  10. Meios e fins do desenvolvimento para Celso Furtado

    Directory of Open Access Journals (Sweden)

    Fabio Antonio de Campos

    2014-10-01

    Full Text Available O objetivo desse artigo é expor o conceito de desenvolvimento para Celso Furtado. Para tanto, nos interessa apresentar o desenvolvimento nacional como um fim em sua abordagem sobre a formação social brasileira Para atingir tal estágio, os meios para o autor seriam assegurados por um típico desenvolvimento capitalista. Dentro dessa problemática, mostraremos também o alcance e os limites dessa concepção para o caráter dependente e subdesenvolvido do capitalismo brasileiro.

  11. DIREITOS HUMANOS, DESENVOLVIMENTO SUSTENTÁVEL E SUSTENTABILIDADE

    OpenAIRE

    Carvalho, Sonia Aparecida de; Silva, Denival Francisco da; Adolfo, Luiz Gonzaga Silva

    2015-01-01

    Este artigo trata da relação intrínseca entre os direitos humanos, o desenvolvimento sustentável e a sustentabilidade. Seu objetivo geral consiste em analisar o modelo de desenvolvimento implementado e a necessária proteção e preservação do meio ambiente ligado à defesa dos direitos humanos. Os objetivos específicos pretendem investigar a distinção dos termos sustentabilidade e desenvolvimento sustentável, como a concretização do direito à sustentabilidade, os critérios e as dimensões da sust...

  12. Influence of dopants on the glow curve structure and energy dependence of LiF:Mg,Cu,Si detectors

    International Nuclear Information System (INIS)

    Knezevic, Z.; Ranogajec-Komor, M.; Miljanic, S.; Lee, J.I.; Kim, J.L.; Music, S.

    2011-01-01

    LiF thermoluminescent material doped with Mg, Cu and Si recently developed by the Korea Atomic Energy Research Institute (KAERI) has shown very good dosimetric properties. Since the thermoluminescence in LiF was found to be dependent on the proper combination of dopants, the investigation of the concentration and type of dopants is very important in developing and characterisation of new TL materials. The aim of this work was to determine the influence of type and concentration of activators on the glow curve structure, sensitivity, reproducibility and on the photon energy response of LiF:Mg,Cu,Si detectors. The energy response was studied in air and on the ISO water phantom in the range of mean photon energies between 33 keV and 164 keV. The morphology and local chemical composition of LiF:Mg,Cu,Si detectors were examined using high resolution scanning electron microscopy (FE-SEM). The results show that type and concentration of activators influence the glow curve and sensitivity. Different dopant concentrations did not show influence on the photon energy response. The sensitivity of LiF:Mg,Cu,Si detector with dopant concentration of Mg = 0.35 mol%, Cu = 0.025 mol% and Si = 0.9 mol% was very high (up to 65 times higher than that of TLD-100). The photon energy response of LiF:Mg,Cu,Si detectors containing all three dopants in various concentrations is in accordance with the IAEA recommendations for individual monitoring.

  13. Influence of dopants on the glow curve structure and energy dependence of LiF:Mg,Cu,Si detectors

    Energy Technology Data Exchange (ETDEWEB)

    Knezevic, Z., E-mail: zknez@irb.h [Ruder Boskovic Institute, Bijenicka 54, 10000 Zagreb (Croatia); Ranogajec-Komor, M.; Miljanic, S. [Ruder Boskovic Institute, Bijenicka 54, 10000 Zagreb (Croatia); Lee, J.I.; Kim, J.L. [Korea Atomic Energy Research Institute, P.O. Box 105 Yuseong, Daejon 305-600 (Korea, Republic of); Music, S. [Ruder Boskovic Institute, Bijenicka 54, 10000 Zagreb (Croatia)

    2011-03-15

    LiF thermoluminescent material doped with Mg, Cu and Si recently developed by the Korea Atomic Energy Research Institute (KAERI) has shown very good dosimetric properties. Since the thermoluminescence in LiF was found to be dependent on the proper combination of dopants, the investigation of the concentration and type of dopants is very important in developing and characterisation of new TL materials. The aim of this work was to determine the influence of type and concentration of activators on the glow curve structure, sensitivity, reproducibility and on the photon energy response of LiF:Mg,Cu,Si detectors. The energy response was studied in air and on the ISO water phantom in the range of mean photon energies between 33 keV and 164 keV. The morphology and local chemical composition of LiF:Mg,Cu,Si detectors were examined using high resolution scanning electron microscopy (FE-SEM). The results show that type and concentration of activators influence the glow curve and sensitivity. Different dopant concentrations did not show influence on the photon energy response. The sensitivity of LiF:Mg,Cu,Si detector with dopant concentration of Mg = 0.35 mol%, Cu = 0.025 mol% and Si = 0.9 mol% was very high (up to 65 times higher than that of TLD-100). The photon energy response of LiF:Mg,Cu,Si detectors containing all three dopants in various concentrations is in accordance with the IAEA recommendations for individual monitoring.

  14. The development of photo-transferred thermoluminescence (PTTL) technique and its application to the routine re-assessment of absorbed dose in the NRPB automated personal dosimetry system

    Science.gov (United States)

    McKinlay, A. F.; Bartlett, D. T.; Smith, P. A.

    1980-09-01

    The re-assessment of absorbed dose has been performed routinely on customer dosimeters as part of the NRPB Automated Thermoluminescence Dosimetry Service. The technique of photo-transferred thermoluminescence (PTTL), as applied to the 2 element (LiF: PTFE discs) NRPB dosimeter inserts, is described.

  15. Thermoluminescence characterization of LiMgF{sub 3}: DyF{sub 3} phosphors exposed to beta radiation

    Energy Technology Data Exchange (ETDEWEB)

    Bernal, R.; Alday S, K.R.; Brown, F.; Cruz V, C. [Universidad de Sonora, A.P. 5-088, 83190 Hermosillo, Sonora (Mexico); Furetta, C.; Cruz Z, E. [ICN-UNAM, A.P. 70-543, 04510 Mexico D.F. (Mexico); Kitis, G. [Aristotle University of Thessaloniki, Nuclear Physics Laboratory, Thessaloniki 54124 (Greece)

    2006-07-01

    LiMgF{sub 3}: DyF{sub 3} phosphors were obtained as polycrystalline solids from the melting of component salts, with two DyF{sub 3} concentrations, 2.02 % mol, and 4.04 % mol. In order to guarantee the homogeneity of composition, the samples were crushed and the resulting powder was pressed to form pellet-shaped phosphors, some of which were sintered at 700 C for 5 h under air atmosphere. Thermoluminescence measurements of beta irradiated samples show that these phosphors exhibit adequate properties to be considered for development of thermoluminescence dosimeters. Integrated thermoluminescence as a function of dose displays a linear dependence with dose for doses below 20.0 Gy. (Author)

  16. Biotecnologia aplicada ao desenvolvimento de vacinas

    Directory of Open Access Journals (Sweden)

    Mariana de Oliveira Diniz

    2010-01-01

    Full Text Available As vacinas representam a estratégia de intervenção com a melhor relação custo-benefício até hoje aplicada em saúde pública. Avanços biotecnológicos em diversas áreas de pesquisa têm contribuído para o desenvolvimento de formulações mais seguras e eficazes. Além disso, a aplicação de ferramentas biotecnológicas no desenvolvimento de vacinas tem provocado mudanças na maneira como pensamos e produzimos esses reagentes tanto para uso em humanos como em animais. Essas tecnologias trazem perspectivas de que, em futuro próximo, vacinas para o controle de doenças infecciosas e degenerativas ainda não passíveis de prevenção possam estar disponíveis. Em particular, vacinas com efeitos terapêuticos, embora representem um enorme desafio a ser vencido, tornam-se cada vez próximas da realidade e, certamente, terão um impacto enorme no tratamento de diversas doenças, como em algumas formas de câncer.Vaccines represent the intervention strategy with the best cost-benefit ratio so far applied in public health. Biotechnological advances in various areas of vaccine research have contributed to the development of safer and more effective formulations. Moreover, application of biotechnology tools to vaccine development has caused changes in the way we think and produce these reagents both for use in humans and animals. Such technologies bring renewed perspectives that, in the near future, vaccines for the control of several non-preventable infectious and degenerative diseases will be available. In particular, the development of vaccines with therapeutic effects, although representing a huge challenge, are getting closer to reality and will have a tremendous impact in the treatment of several diseases such as some cancer forms.

  17. Verification of angular dependence in MOSFET detector

    International Nuclear Information System (INIS)

    Souza, Clayton H.; Shorto, Julian M.B.; Siqueira, Paulo T.D.; Nunes, Maíra G.; Silva Junior, Iremar A.; Yoriyaz, Hélio

    2017-01-01

    In vivo dosimetry is an essential tool for quality assurance programs, being a procedure commonly performed with thermoluminescent dosimeters (TLDs) or diodes. However, a type of dosimeter that has increasing popularity in recent years is the metal-oxide-semiconductor field effect transistor (MOSFET) detector. MOSFET dosimeters fulfill all the necessary characteristics to realize in vivo dosimetry since it has a small size, good precision and feasibility of measurement, as well as easy handling. Nevertheless, its true differential is to allow reading of the dose in real time, enabling immediate intervention in the correction of physical parameters deviations and anticipation of small anatomical changes in a patient during treatment. In order for MOSFET dosimeter to be better accepted in clinical routine, information reporting performance should be available frequently. For this reason, this work proposes to verify reproducibility and angular dependence of a standard sensitivity MOSFET dosimeter (TN-502RD-H) for Cs-137 and Co-60 sources. Experimental data were satisfactory and MOSFET dosimeter presented a reproducibility of 3.3% and 2.7% (1 SD) for Cs-137 and Co-60 sources, respectively. In addition, an angular dependence of up to 6.1% and 16.3% for both radioactive sources, respectively. It is conclusive that MOSFET dosimeter TN-502RD-H has satisfactory reproducibility and a considerable angular dependence, mainly for the Co-60 source. This means that although precise measurements, special attention must be taken for applications in certain anatomical regions in a patient. (author)

  18. Verification of angular dependence in MOSFET detector

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Clayton H.; Shorto, Julian M.B.; Siqueira, Paulo T.D.; Nunes, Maíra G.; Silva Junior, Iremar A.; Yoriyaz, Hélio, E-mail: chsouza@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-07-01

    In vivo dosimetry is an essential tool for quality assurance programs, being a procedure commonly performed with thermoluminescent dosimeters (TLDs) or diodes. However, a type of dosimeter that has increasing popularity in recent years is the metal-oxide-semiconductor field effect transistor (MOSFET) detector. MOSFET dosimeters fulfill all the necessary characteristics to realize in vivo dosimetry since it has a small size, good precision and feasibility of measurement, as well as easy handling. Nevertheless, its true differential is to allow reading of the dose in real time, enabling immediate intervention in the correction of physical parameters deviations and anticipation of small anatomical changes in a patient during treatment. In order for MOSFET dosimeter to be better accepted in clinical routine, information reporting performance should be available frequently. For this reason, this work proposes to verify reproducibility and angular dependence of a standard sensitivity MOSFET dosimeter (TN-502RD-H) for Cs-137 and Co-60 sources. Experimental data were satisfactory and MOSFET dosimeter presented a reproducibility of 3.3% and 2.7% (1 SD) for Cs-137 and Co-60 sources, respectively. In addition, an angular dependence of up to 6.1% and 16.3% for both radioactive sources, respectively. It is conclusive that MOSFET dosimeter TN-502RD-H has satisfactory reproducibility and a considerable angular dependence, mainly for the Co-60 source. This means that although precise measurements, special attention must be taken for applications in certain anatomical regions in a patient. (author)

  19. Study on thermoluminescence dating for Nideping terrace of Dongchuan, Yunnan province

    International Nuclear Information System (INIS)

    Zhang Bin; Wei Mingjian; Liu Chao; Zhang Yongdong; Zhou Rui; Liu Junxin; Liu Tiantian; Zhao Qiuyue; Song Bo

    2013-01-01

    The sequence of geological age on Nideping terrace in Dongchuan, Yunnan Province was established by thermoluminescence. The result shows that the age of the terrace is 9.3-57.1 ka. The vertical age of ancient debris flow terraces was established, and the time structure of Nideping mud was received. The age data was provided for the restoration ancient environment of the debris flow. It is shown that the debris flow deposits have discontinuities through age data and exist age inversion. The radioactive elements such as uranium, thorium, potassium may be leaching deposition affected by the presence of local rainfall and the annual dose rate increases with depth. (authors)

  20. Research of thermoluminescence dating for ancient debris flow materials in Qingshui river basin of Beijing

    International Nuclear Information System (INIS)

    Liu Junxin; Wei Mingjian; Zhou Rui; Zhang Bin; Liu Tiantian

    2012-01-01

    The thermoluminescence age of the samples for ancient debris flow terraces material of Lingshan and Hongshuikou, which are in Qingshui River Basin of Beijing, was studied using the thermo luminescence technology. The age increases with the increasing depth of two ancient debris flow profile, and the deeper debris flow deposits material the more of the environmental radiation dose is. The trend with depth of U, Th and K contents and annual dose is consistency. And the change with depth of Th content is more discrete than that of U, K contents. (authors)

  1. In vivo dosimetry thermoluminescence dosimeters during brachytherapy with a 370 GBq {sup 192}Ir source

    Energy Technology Data Exchange (ETDEWEB)

    Cuepers, S.; Piessens, M.; Verbeke, L.; Roelstraete, A. [Onze-Lieve-Vrouw Hospitaal, Aalst (Belgium). Dept. of Radiotherapy and Oncology

    1995-12-01

    When using LiF thermoluminescence dosimeters in brachytherapy, we have to take into account the properties of a high dose rate {sup 192}Ir source (energy spectrum ranging form 9 to 885 keV, steep dose gradient in the vicinity of the source) and these of the dosimeters themselves (supralinearity, reproducibility, size). All these characteristics combine into a set of correction factors which have been determined during in phantom measurements. These results have then been used to measure the dose delivered to organs at risk (e.g. rectum, bladder, etc.) during high dose rate brachytherapy with a 370 GBq {sup 192}Ir source for patients with gynaecological tumors.

  2. Thermoluminescent behavior of polyminerals from irradiated natural species (peppermint, pepper and origanum)

    International Nuclear Information System (INIS)

    Cruz Z, E.; Calderon, T.; Pineda, S.; Guzman M, A.; Gastelum, S.; Barboza F, M.; Calderon, T.

    2003-01-01

    The thermoluminescent behaviour of polyminerals from natural species was obtained in order to identify irradiated samples. The polyminerals was separated from organic part in the samples using methanol-water mixed 40:60. The commercial samples was exposured from 1 to 40 kGy in Gammabeam 651PT facility irradiator at National University of Mexico (UNAM). The glow curves from polyminerals shows a good behaviour for each dose, and the TL emission decays was present for 180 days storage in a dark room at room temperature. The maximum TL signals was located in around 220 for the samples, it is closely to TL emission from quartz and feldspars. (Author)

  3. Thermoluminescence of films of metal oxides and its application to the low energy ionizing radiation dosimetry

    International Nuclear Information System (INIS)

    Azorin N, J.; Rivera M, T.; Furetta, C.; Falcony G, C.; Martinez S, E.; Garcia H, M.

    2002-01-01

    The obtained results from 1997 to date in the project S tudy of the thermoluminescence of metal oxides and their application to the ionizing radiation as regards to the development of ZrO 2 and of Al 2 O 3 doped and without doped films with rare earths are presented. The obtained results irradiating ZrO 2 and of Al 2 O 3 films with ultraviolet light and visible light have been satisfactory; whereas these materials have resulted promising to measure beta particles, X-rays and low energy gamma rays. (Author)

  4. In vivo dosimetry thermoluminescence dosimeters during brachytherapy with a 370 GBq 192Ir source

    International Nuclear Information System (INIS)

    Cuepers, S.; Piessens, M.; Verbeke, L.; Roelstraete, A.

    1995-01-01

    When using LiF thermoluminescence dosimeters in brachytherapy, we have to take into account the properties of a high dose rate 192 Ir source (energy spectrum ranging form 9 to 885 keV, steep dose gradient in the vicinity of the source) and these of the dosimeters themselves (supralinearity, reproducibility, size). All these characteristics combine into a set of correction factors which have been determined during in phantom measurements. These results have then been used to measure the dose delivered to organs at risk (e.g. rectum, bladder, etc.) during high dose rate brachytherapy with a 370 GBq 192 Ir source for patients with gynaecological tumors

  5. Thermoluminescent characterization of thin films of aluminium oxide submitted to beta and gamma radiation

    International Nuclear Information System (INIS)

    Villagran, E.; Escobar A, L.; Camps, E.; Gonzalez, P.R.; Martinez A, L.

    2002-01-01

    By mean of the laser ablation technique, thin films of aluminium oxide have been deposited on kapton substrates. These films present thermoluminescent response (Tl) when they are exposed to beta and gamma radiation. The brilliance curves show two peaks between 112 C and 180 C. A dose-response relationship study was realized and the Tl kinetic parameters were determined using the computerized deconvolution of the brilliance curve (CGCD). The thin films of aluminium oxide have potential applications as ultra.thin radiation dosemeters. (Author)

  6. Investigation about the thermal features of the ovens used for thermoluminescence

    International Nuclear Information System (INIS)

    Scarpa, G.; Caporali, C.; Moscati, M.

    1991-02-01

    The present paper reports the results of an investigation carried out by the PAS-FIBI-DOSIBIO laboratory (ENEA, Casaccia, Roma) about the thermal features of the ovens used for annealing treatments of TL dosemeters. A total number of 45 commercial ovens and muffle furnaces were studied. belonging to 24 Italian Health Physics laboratories. The investigation has shown that the majority of the ovens do not possess a degree of accuracy, stability, uniformity and reproducibility suitable for their use in the field of thermoluminescence dosimetry. Practical suggestions are also given in order to reduce the effects of some of the negative characteristics found in most ovens. (author)

  7. The IAEA/WHO thermoluminescent dosimetry intercomparison used for the improvement of clinical dosimetry

    International Nuclear Information System (INIS)

    Racoveanu, N.T.

    1981-01-01

    Results of thermoluminescent dosimetry collected over 5 years in the Eastern Mediterranean region of WHO were analyzed in an attempt to improve clinical dosimetry. Data for 16 radiotherapy departments showed considerable inconsistencies. It was found that the clinical dosemeters used by 3 of the departments were not working properly. The remainder of the departments had one or more dosemeters in perfect working order but the procedure for measuring machine output was inadequate or the correction factors (pressure, temperature) were wrongly applied due to lack of reliable instruments for such measurements. Problems encountered in the sending and returning of TLD dosemeters for assessment are discussed

  8. Al2 O3:Cr,Ni: a possible thermoluminescent dosemeter

    International Nuclear Information System (INIS)

    Mariani R, Francisco; Roman B, Alvaro; Saavedra S, Renato; Ibarra S, Angel

    1996-01-01

    Results from a study on the thermoluminescent (Tl) emission from Al 2 O 3 :Cr,Ni are presented. The measurements were obtained for evaluation of the Al 2 O 3 :Cr,Ni dosimetric properties. Different crystal batches were exposed to two kind of ionizing radiation (X-ray and β - ). The Tl spectrum has a main peak with high thermal and optical stability, deviating from linearity for doses lower than 3.6 Gy. Furthermore, this material shows advantages (thermal resistance, reusability, multiple heating cycles) compared to TLD-100. Measured Al 2 O 3 :Cr,Ni properties indicate that it could be used as a dosemeter. (author)

  9. New thermoluminescent dosimeters (TLD): optimization and characterization of TLD threads sterilizable by autoclave.

    Science.gov (United States)

    Jarnet, D; Denizot, B; Hindré, F; Venier-Julienne, M C; Lisbona, A; Bardiès, M; Jallet, P

    2004-05-07

    To improve the performance of mono-extruded TLD threads as a dosimetric thermoluminescent tool (French Patent 9903729), a new process was developed by co-extrusion methodology leading to threads of 600 microm diameter with a 50 microm homogeneous polypropylene sheath. In this optimization work, study of parameters such as LiF:Mg,Cu,P powder granulometry, load rate and proportion of components led to an increased sensitivity of around 40%. Moreover, the co-extrusion technique allowed the threads to be sterilized by humid steam (134 degrees C/18 min) without significant variation of the linearity response between 0 and 30 Gy after gamma irradiation (60Co).

  10. Thermoluminescence of CaCO3:Dy and CaCO3:Mn

    International Nuclear Information System (INIS)

    Bapat, V.N.; Nambi, K.S.V.

    1976-01-01

    CaCO 3 samples doped with Dy and Mn were prepared in the laboratory by co-precipitation techniques. Thermoluminescence and emission spectra of these phosphors were studied and were compared with those of the naturally occuring calcite and undoped CaCO 3 samples. Dy-doping seems to give a more efficient phosphor and indicates a possibility of getting a better phosphor by a judicious choice of a rare earth doping of CaCO 3 . Interesting result have been obtained on the TL glow curve variations of these phosphors with different temperature treatments prior to irradiation. (author)

  11. Identification of irradiated foods using the thermoluminescence apparatus TOLEDO - Preliminary study

    International Nuclear Information System (INIS)

    Vo Van Thuan; Pham Quang Vinh; Dang Thanh Luong; Pham Quang Dien

    1990-01-01

    The thermoluminescence (TL) method based on TOLEDO apparatus has been carried out, firstly in Vietnam, for identification of some irradiated dry food: paprika, pepper, curry and green beans. The TL effect of irradiation with dose 0.8 Mrad is greater than the effect of unirradiated samples at least by one order. The TOLEDO was proved to be able to determine TL intensity as function of absorbed dose and post-irradiation storage time. The measurement procedure is rapid and simple, that expect to be used as a standard control method of irradiated food. (author). 6 refs, 2 figs, 1 tab

  12. Thermoluminescent relative efficiencies of TLD-100 for nitrogen ions respect of gamma radiation

    International Nuclear Information System (INIS)

    Concha S, K.; Avila, O.; Gamboa de Buen, I.; Rodriguez V, M.; Buenfil, A.E.; Ruiz T, C.; Brandan, M.E.

    2004-01-01

    The purpose of this work is to measure the thermoluminescent relative efficiency of those TLD-100 dosemeters irradiated with nitrogen ions with respect to the gamma radiation of 60 Co, in function of the linear energy transfer (LET). Two energy of such nitrogen ions were selected that has the same value from LET when impacting in the dosemeters but with E 1 energy (4.8 MeV) and E 2 (9.95 MeV) smaller and greater respectively that the energy of the Bragg peak. (Author)

  13. In vivo thermoluminescent dosimetry on the radiotherapy of limphomas, esophageal and uterine tumour

    International Nuclear Information System (INIS)

    Morales, F.C.

    1982-01-01

    A comparative study between dose distribution in pre-selected tumoral plans was established through measurements with thermoluminescent dosimeters and calculations based on 'scatter-air-ratios' properties, isodose curves and collected data. Clinic dosimetry was performed 'in vivo' with LiF dosimeters (TLD-100) and LiF Teflon (1 mm theta, 6 mm lenght). Patients with Hodgkin's disease, carcinoma of the esophagus and of the uterine cervix were selected. Telecobaltherapy was used for these groups of neoplasic conditions. (M.A.C.) [pt

  14. Rede de Protagonismo Local para o Desenvolvimento Global

    DEFF Research Database (Denmark)

    Weber, Ángela; Hermann, Roberto Rivas

    Este artigo pretende fazer uma reflexão sobre metodologia a ser desenvolvida e utilizada num projeto de desenvolvimento local, através das ações protagonizadas pela própria comunidade. Para isso parte de uma discussão sobre o conceito de desenvolvimento sustentável, e a seguir propõe a busca de f...

  15. Development of Mg B4 O7:Dy thermoluminescent solid dosemeter for using on the thermal neutron dosimetry

    International Nuclear Information System (INIS)

    Potiens Junior, A.J.; Campos, L.L.; Todo, A.S.

    1992-01-01

    The magnesium tetraborate doped with dysprosium (Mg B 4 O 7 :O y ) thermoluminescent phosphor is developed, containing boron, which boron 10 isotope has high cross section for thermal neutrons by 10 B (n,α) 7 Li reaction. The nitric acid concentration, the number of washing for removing the excess of boric acid, the powder granulation of Mg B 4 O 7 :O y , the percentage of teflon used as binder and the reproducibility of thermoluminescent answer are also presented. (C.G.C.)

  16. Thermal annealing of high dose radiation induced damage at room temperature in alkaline. Stored energy, thermoluminescence and coloration

    International Nuclear Information System (INIS)

    Delgado, L.

    1980-01-01

    The possible relation between stored energy, thermoluminescence and colour centre annealing in gamma and electron irradiated alkali halides is studied. Thermoluminescence occurs at temperature higher than the temperature at which the main stored energy peak appears. No stored energy release is detected in additively coloured KC1 samples. Plastic deformation and doping with Ca and Sr induce a stored energy spectrum different from the spectrum observed in pure and as cleaved samples, but the amount of stored energy does not change for a given irradiation dose.Capacity of alkali halides to store energy by irradiation increases as the cation size decreases. (Author) 51 refs

  17. Biotecnologia e desenvolvimento sustentável

    Directory of Open Access Journals (Sweden)

    Ana Clara Guerrini Schenberg

    2010-01-01

    Full Text Available A biotecnologia pode desempenhar um papel importante para atingir as metas da sustentabilidade. No presente trabalho, são descritos diferentes exemplos bem-sucedidos de micro-organismos especialmente desenhados para otimizar a produção de etanol, a produção de plásticos biodegradáveis a partir de recursos renováveis e a biorremediação de metais tóxicos. Esses processos biotecnológicos contribuem significantemente para promover o desenvolvimento sustentável, embora possam, por enquanto, não ser ainda competitivos em relação às tecnologias convencionais.Biotechnology can play an important role to reach the goals of sustainability. In the present work, we describe successful examples of microorganisms especially designed for optimizing ethanol production, biodegradable plastics production from renewable resources, and toxic metals bioremediation. These biotechnological processes significantly contribute to promote sustainable development, although they may, at present, not be competitive with the conventional technologies.

  18. CaSO4:DY,Mn: A new and highly sensitive thermoluminescence phosphor for versatile dosimetry

    Science.gov (United States)

    Bahl, Shaila; Lochab, S. P.; Kumar, Pratik

    2016-02-01

    With the advent of newer techniques for dose reduction coupled with the development of more sensitive detectors, the radiation doses in radiological medical investigation are decreasing. Nevertheless, keeping the tenet in mind that all radiation doses could entail risk, there is a need to develop more sensitive dosimeters capable of measuring low doses. This paper gives the account of the development of a new and sensitive phosphor CaSO4:Dy,Mn and its characterization. The standard production procedure based on the recrystallization method was used to prepare CaSO4:Dy,Mn. The Thermoluminescence (TL) studies were carried out by exposing it with gamma radiation (Cs-137) from 10 μGy to 100 Gy. The theoretical studies to determine the number of peaks and kinetic parameters related to the TL glow peaks in CaSO4:Dy,Mn was performed using the Computerized Glow Curve Deconvolution (CGCD) method. Experiments were performed to determine optimum concentration of the dopants Dysprosium (Dy) and Mangnese (Mn) in the host CaSO4 so that maximum sensitivity of the phosphor may be achieved. The optimum dopant concentration turned out to be 0.1 mol%. As there were two dopants Dy and Mn their relative ratio were varied in steps of 0.025 keeping the concentration of total dopant (Dy and Mn) 0.1 mol% always. The maximum TL intensity was seen in the CaSO4:Dy(0.025),Mn(0.075) combination. The TL sensitivity of this phosphor was found to be about 2 and 1.8 times higher than that of popular phosphor CaSO4:Dy and LiF:Mg,Cu,P (TLD-700H) respectively. This new phosphor CaSO4:Dy,Mn showed fading of 11% which is similar to that of the standard phosphor CaSO4:Dy. The paper concludes that the new, highly sensitive TL phosphor CaSO4:Dy,Mn has shown higher sensitivity and hence the potential to replace commonly used CaSO4:Dy.

  19. GADRAS Detector Response Function.

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, Dean J.; Harding, Lee; Thoreson, Gregory G; Horne, Steven M.

    2014-11-01

    The Gamma Detector Response and Analysis Software (GADRAS) applies a Detector Response Function (DRF) to compute the output of gamma-ray and neutron detectors when they are exposed to radiation sources. The DRF is fundamental to the ability to perform forward calculations (i.e., computation of the response of a detector to a known source), as well as the ability to analyze spectra to deduce the types and quantities of radioactive material to which the detectors are exposed. This document describes how gamma-ray spectra are computed and the significance of response function parameters that define characteristics of particular detectors.

  20. Synthesis and thermoluminescence characteristics of gamma and proton irradiated nanocrystalline MgB{sub 4}O{sub 7}: Dy, Na

    Energy Technology Data Exchange (ETDEWEB)

    Bahl, Shaila, E-mail: shailaphy@gmail.com [Medical Physics Unit, All India Institute of Medical Sciences, New Delhi-110029 (India); Pandey, Anant [Department of Physics, Sri Venkateswara College, University of Delhi, Benito Juarez Road, Dhaula Kuan, New Delhi-110021 (India); Lochab, S.P. [Inter-University Accelerator Centre, Aruna Asaf Ali Marg, Post Box 10502, New Delhi 110067 (India); Aleynikov, V.E.; Molokanov, A.G. [Joint Institute for Nuclear Research, Dubna 141980 (Russian Federation); Kumar, Pratik, E-mail: drpratikkumar@hotmail.com [Medical Physics Unit, All India Institute of Medical Sciences, New Delhi-110029 (India)

    2013-02-15

    This paper investigates the use of nanocrystalline MgB{sub 4}O{sub 7}: Dy, Na thermoluminescent (TL) dosimeter synthesized by the combustion method for the assessment of proton beam and gamma radiation doses, primarily on the shape of the TL glow curves. TEM and XRD studies revealed that the particles were tubular in shape and approximately 50 nm in size. The heating rate which affects the thermal quenching as well as the annealing temperature of the material was optimized. Samples in pellet form were irradiated by 150 MeV proton beams (1-450 Gy) and also with gamma rays (0.1-1000 Gy) for comparison. Trapping parameters of proton beam and gamma-irradiated materials were also obtained after deconvolution of the glow curves. In case of gamma-irradiation the nanophosphor showed an intense TL glow peak at 400 K and a small peak at 512 K, however in case of proton irradiation the nanophosphor showed a peak at 477 K and a small shoulder at around 450 K. The dose response curve of the nanophosphor for proton irradiation was found to be linear up to 350 Gy with a slight supralinearity for higher doses whereas the nanophosphor's gamma dose response was found to be linear up to 1000 Gy with a slight saturation towards the end dose. Photoluminescence excitation and emission spectra of the sample were also studied. Fading and reusability studies of the nanophosphor further confirmed the phosphor's suitability for radiation dosimetry. - Highlights: Black-Right-Pointing-Pointer This study reports the thermoluminescent reponse of nanocrystalline MgB{sub 4}O{sub 7}: Dy, Na to gamma and proton beam. Black-Right-Pointing-Pointer Paper focusses on the different shape of the glow curve obtained. Black-Right-Pointing-Pointer Detector can be used as a diffentiator for gamma and proton beam doses. Black-Right-Pointing-Pointer Can also be used for estimating higher doses of the concerned beams. Black-Right-Pointing-Pointer Characterization by other techniques has also been done

  1. Drift Chambers detectors; Detectores de deriva

    Energy Technology Data Exchange (ETDEWEB)

    Duran, I.; Martinez laso, L.

    1989-07-01

    We present here a review of High Energy Physics detectors based on drift chambers. The ionization, drift diffusion, multiplication and detection principles are described. Most common drift media are analysed, and a classification of the detectors according to its geometry is done. Finally the standard read-out methods are displayed and the limits of the spatial resolution are discussed. (Author) 115 refs.

  2. Rare-earths influence in the thermoluminescent response of monoclinic ZrO2

    International Nuclear Information System (INIS)

    Mendoza A, D.; Gonzalez M, P.R.; Vasquez L, M.J.; Rubio R, E.

    2005-01-01

    Zirconium oxide (ZrO 2 ) with rare-earths (Nd, Dy, Eu and Y) as dopant were prepared by sol gel method and irradiated with gamma radiation. The thermoluminescent (TL) signal was studied as function of the impurities present for temperatures from 50 to 350 C. Pure ZrO 2 produces a strong TL signal induced by gamma radiation, with a maximum located at 150 C, while ZrO 2 doped with Nd, Dy and Y showed a TL signal with minor intensity, but with a maximum like to pure ZrO 2 . However, when Eu is present as impurity the TL signal is much smaller than pure ZrO 2 , with a maximum very enlarged. These results indicate that exits a strong influence of the rare-earths presents in the TL response and opens the possibility to control the TL signal in a wide range of dosages allowing to use these systems as a wide range dosimeter. Details of the thermoluminescent behavior of pure and doped ZrO 2 will be discussed. (Author)

  3. Nanoparticle effects on the thermoluminescent properties of monoclinic ZrO2 exposed to UV radiation

    International Nuclear Information System (INIS)

    Villa S, G.; Mendoza A, D.; Gutierrez W, C.E.; Perez H, R.; Gonzalez M, P.R.

    2007-01-01

    In this work, an analysis of the thermoluminescent (TL) signal induced by ultraviolet radiation in monoclinic zirconium oxide (ZrO 2 ) doped with metallic nanoparticles is presented. Thermoluminescent response of pure ZrO 2 shows two peaks, the first one at 61 C and the second one at 144 C when it was exposed to UV radiation; being the first peak more intense than the second. When nanoparticles are added, the glow curve also shows two peaks, however, the intensity and the glow curve shape was lightly different depending of the kind of the nanoparticles added. For example, ZrO 2 with Au nanoparticles or Au-Pd nanoparticles produced a glow curve with two peaks almost with same intensity. These results indicate that there is an influence of the-metallic nanoparticles on the TL response. This study was complemented with an analysis of the fading behavior to evaluate the possibility to use this kind of material as dosimeter of ultraviolet radiation. (Author)

  4. Advances in the synthesis of ZnS for thermoluminescence dosimetry

    International Nuclear Information System (INIS)

    Cruz V, C.; Burruel I, S.E.; Cota V, E.; Chernov, V.; Bernal, R.; Castano, V.M.

    2007-01-01

    Full text: ZnS is a semiconductor that displays high photoluminescence very attractive for optoelectronic applications, such as light emitting diodes (LEDs), and flat screens. Only recently, an interest has arisen to investigate its thermoluminescence (TL) properties in order to evaluate its dosimetric capabilities, and detailed characterization of the TL properties of ZnS has been reported for ZnS films deposited by the spray pyrolysis technique rather than on bulk samples. The route followed to fabricate a given material strongly influences their resulting physical properties, and the chemical methods are a very reliable and low cost alternative to obtain semiconducting materials. Recently, we reported the fabrication of pellet-shaped ZnO thermoluminescent phosphors by thermal annealing under air atmosphere of chemically synthesized ZnS. In this work, we present the first results related to the TL properties of new phosphors obtained by annealing this precursor ZnS in vacuum and nitrogen atmospheres instead of air, in an attempt to avoid the oxidation and obtain crystalline ZnS. The characteristic glow curves of the phosphors in such a way obtained display TL emission from 60 to 300 C, with a maximum at 117 C when a 5 C/s heating rate is used after beta exposure. Due to the high intensity TL at relative low temperature together with the TL emission at higher temperature, these new phosphors may be developed for both, persistent and thermally stimulated luminescence dosimetry. (Author)

  5. Fit of second order thermoluminescence glow peaks using the logistic distribution function

    International Nuclear Information System (INIS)

    Pagonis, V.; Kitis, G.

    2001-01-01

    A new thermoluminescence glow curve deconvolution (GCD) function is introduced which accurately describes second order thermoluminescence (TL) curves. The logistic asymmetric (LA) statistical probability function is used with the function variables being the maximum peak intensity (I m ), the temperature of the maximum peak intensity (T m ) and the LA width parameter a 2 . An analytical expression is derived from which the activation energy E can be calculated as a function of T m and the LA width parameter a 2 with an accuracy of 2% or better. The accuracy of the fit was tested for E values ranging from 0.7 to 2.5 eV, for s values between 10 5 and 10 25 s -1 , and for trap occupation number n 0 /N between 1 and 10 -6 . The goodness of fit of the logistic asymmetric function is described by the Figure of Merit (FOM) which is found to be of the order of 10 -2 . Preliminary results show that the GCD described here can easily be extended to the description of general order TL glow curves by varying the asymmetry parameter of the logistic asymmetric function. It is concluded that the TL kinetic analysis of first, second and general order TL glow curves can be performed with high accuracy and speed by using commercially available statistical packages that incorporate the Weibull and logistic asymmetric functions. (author)

  6. A comparative study of the thermoluminescence properties of several varieties of Brazilian natural quartz

    International Nuclear Information System (INIS)

    Brito Farias, Thiago Michel de; Watanabe, Shigueo

    2012-01-01

    The following varieties of natural quartz, as the blue, the green, the red, the pink, the black, the sulphurous and the milky quartz, have been investigated concerning their thermoluminescence properties. For comparison sake natural colorless alpha quartz has been include. Since X-rays diffraction analysis has shown that all of them have the same crystal structure as the alpha quartz, it is expected that no great change in the TL property should be found, however, that was not the case. The TL peaks at 110, 175, 220, 325 and 375 °C observed in the alpha quartz are not found in all the varieties of quartz, for instance, the sulphurous quartz presented only 110° and 245° peaks, the pink one presented just 110, 220 and 375 °C peaks and so on. In respect to TL response as function of gamma ray dose a quite varied behavior has been observed and discussed. - Highlights: ► We evaluated seven varieties of natural quartz. ► Thermoluminescence properties were compared. ► Their properties are different. ► The models proposed for the TL emission cannot be applied.

  7. Leaked filters for energetic and angular dependence corrections of thermoluminescent response

    International Nuclear Information System (INIS)

    Manzoli, Jose Eduardo; Shammas, Gabriel Issa Jabra; Campos, Vicente de Paulo de

    2007-01-01

    Many thermoluminescent materials has been developed and used for photon personal dosimetry but no one has all desired characteristics alone. These characteristics include robustness, high sensitivity, energy photon independence, large range of photon energy detection, good reproducibility and small fading. The phosphors advantages begin to be more required and its disadvantages have became more apparent, in a global market more and more competitive. Calcium Sulfate Dysprosium doped (CaSO 4 :Dy) and Calcium Fluoride Manganese doped (CaF 2 :Mn) phosphor Thermoluminescent Dosimeters (TLDs) have been used by many laboratories. They are used in environmental and area monitoring, once they present more sensibility than other phosphors, like LiF:Mg. Theirs main disadvantage is the strong energetic dependence response, which must be corrected for theirs application in routine, where the kind of photon radiation is unknown a priori. An interesting way to make this correction is to interject a leaked filter between the beam and the phosphor, where the beam could strike the phosphor at any angle. In order to reduce the energetic dependence on any incidence angle, this work presents experimental and simulation studies on some filter geometries. It was made TL readings and simulations on TL responses to photon irradiations with gamma rays of 60 Co and X-rays of 33; 48 and 118 keV, on many incidence angles from zero to ninety degrees. The results pointed out the best filter thicknesses and widths, in order to optimize the correction of energetic dependence for the studied geometries. (author)

  8. Dating of aragonite and dolomite from Devil's cave - SP, by dosimetric thermoluminescent method (DTL) and ESR

    International Nuclear Information System (INIS)

    Tatumi, S.H.

    1987-01-01

    We have investigated TL (Thermoluminescence) and ESR (electron spin resonance) properties of aragonite and dolomite found at ''Caverna do Diabo (Devil's cave)'' in the state of Sao Paulo to determine the ages of these geological materials. The aragonite, which is not a thermoluminescent material, shows one ESR signal whit g = 2.003. We obtained the age of 1.1 x 10 5 years and the growth rate of 1 μ m/year by the sample calibration with additional Y irradiation. The dolomite gives a TL glow curve with three distinct peaks at 261, 334 and 395 0 C. We found that the fit for the TL glow curve to second-order kinetics can be considerered as very acceptable. Using the second TL peak we obtained the age of 9.4 x 10 5 years and the compatible values of the activation energy (1.90 ± 0,07 eV) by the following methods: Hyperbolic heating, isothermal decay and fractional glow technique. We observed many ESR absorption signals in the dolomite. Three principal signal com g = 2.002, 2.003 and 2.005 were studied. We found that the first and second ESR signals were atributed to the CO 2 - and/or CO 3 3- centers and the last to the CO 3 - centers, and observed that the first ESR signal might related with the second TL peak and the TL sensitivity were associated with the concentration of Mn 2+ [pt

  9. Thermoluminescent properties of Dy doped calcium borate based glass for dose measurement subjected to photon irradiation

    Science.gov (United States)

    Tajuddin, H. A.; WanHassan, W. M. S.; Abdul Sani, S. F..; Shaharin, Nurul Syazlin

    2017-10-01

    This study presents the thermoluminescent (TL) dosimetric properties of calcium borate glass with various dopant concentration of dysprosium (Dy). Calcium borate glass is a new potential material to be used in radiation measurement with absorption coefficient that is close to human bone. A series of glasses based on chemical equation xCaO-(100-x) B2O3 system, x = 0.1, 0.2, 0.3, 0.4, 0.5 (0glass samples were carried out and the result showed a broad peak, which confirmed the amorphous nature of the glass. The 70B2O3-30CaO glass sample was found as the most stable among other glass samples studied. Present work focuses on 70B2O3-30CaO glass of (0.01-0.4) mol% Dy-doped in order to investigate the thermoluminescence (TL) properties, in particular, dose-response and fading. The glass samples were irradiated to dose range of 0.5-4.0 Gy subjected to 6MV photon irradiations of LINAC Primus MLC 3339. TL response of 0.3 mol% Dy-doped 70B2O3-30CaO glass was found to produce highest response, with good linear dose- response relationship.

  10. Thermoluminescence properties of lithium magnesium borate glasses system doped with dysprosium oxide.

    Science.gov (United States)

    Mhareb, M H A; Hashim, S; Ghoshal, S K; Alajerami, Y S M; Saleh, M A; Razak, N A B; Azizan, S A B

    2015-12-01

    We report the impact of dysprosium (Dy(3+)) dopant and magnesium oxide (MgO) modifier on the thermoluminescent properties of lithium borate (LB) glass via two procedures. The thermoluminescence (TL) glow curves reveal a single prominent peak at 190 °C for 0.5 mol% of Dy(3+). An increase in MgO contents by 10 mol% enhances the TL intensity by a factor of 1.5 times without causing any shift in the maximum temperature. This enhancement is attributed to the occurrence of extra electron traps created via magnesium and the energy transfer to trivalent Dy(3+) ions. Good linearity in the range of 0.01-4 Gy with a linear correlation coefficient of 0.998, fading as low as 21% over a period of 3 months, excellent reproducibility without oven annealing and tissue equivalent effective atomic numbers ~8.71 are achieved. The trap parameters, including geometric factor (μg), activation energy (E) and frequency factor (s) associated with LMB:Dy are also determined. These favorable TL characteristics of prepared glasses may contribute towards the development of Li2O-MgO-B2O3 radiation dosimeters. Copyright © 2015 John Wiley & Sons, Ltd.

  11. Thermoluminescent properties of Dy doped calcium borate based glass for dose measurement subjected to photon irradiation

    Directory of Open Access Journals (Sweden)

    Tajuddin H. A.

    2017-01-01

    Full Text Available This study presents the thermoluminescent (TL dosimetric properties of calcium borate glass with various dopant concentration of dysprosium (Dy. Calcium borate glass is a new potential material to be used in radiation measurement with absorption coefficient that is close to human bone. A series of glasses based on chemical equation xCaO-(100-x B2O3 system, x = 0.1, 0.2, 0.3, 0.4, 0.5 (0< x <100 % weight have been prepared by melt quenching method. The X-ray diffraction analysis of glass samples were carried out and the result showed a broad peak, which confirmed the amorphous nature of the glass. The 70B2O3-30CaO glass sample was found as the most stable among other glass samples studied. Present work focuses on 70B2O3-30CaO glass of (0.01-0.4 mol% Dy-doped in order to investigate the thermoluminescence (TL properties, in particular, dose-response and fading. The glass samples were irradiated to dose range of 0.5-4.0 Gy subjected to 6MV photon irradiations of LINAC Primus MLC 3339. TL response of 0.3 mol% Dy-doped 70B2O3-30CaO glass was found to produce highest response, with good linear dose- response relationship.

  12. Infrared luminescence and thermoluminescence of lithium borate glasses doped with Sm3+ ions

    Directory of Open Access Journals (Sweden)

    Anjaiah J.

    2015-03-01

    Full Text Available Thermoluminescence (TL characteristics of X-ray irradiated pure and doped with Sm3+ ions Li2O-MO-B2O3 (where MO=ZnO, CaO, CdO glasses have been studied in the temperature range of 303 to 573 K. All the pure glasses exhibited single TL peaks at 382 K, 424 K and 466 K. When these glasses were doped with Sm3+ ions no additional peaks have been observed but the glow peak temperature of the existing glow peak shifted gradually towards higher temperatures with gain in intensity of TL light output. The area under the glow curve was found to be maximum for Sm3+ doped glasses mixed with cadmium oxide as a modifier. The trap depth parameters associated with the observed TL peaks have been evaluated using Chen’s formulae. The possible use of these glasses in radiation dosimetry has been described. The results clearly showed that samarium doped cadmium borate glass has a potential to be considered as a thermoluminescence dosimeter.

  13. Thermoluminescence dating analysis at the site of an ancient brick structure at Pengkalan Bujang, Malaysia

    International Nuclear Information System (INIS)

    Sabtu, Siti Norbaini; Mahat, Rosli Hj; Amin, Yusoff Mohd; Price, David M; Bradley, D.A.; Maah, Mohd Jamil

    2015-01-01

    Bujang Valley is a well-known historical complex found in the north-west of peninsular Malaysia; more than 50 ancient monuments and hundreds of artefacts have been discovered throughout the area. The discovery of these suggests Bujang Valley to have been an important South East Asian trading centre over the period from the 10th to 14th centuries. Present work concerns thermoluminescence (TL) dating analysis of shards collected from a historic monument located at Pengkalan Bujang in Bujang Valley. All the shards were prepared using the fine grain technique and the additive dose method was applied in determining the paleodose of each shard. The annual dose rate was obtained by measuring the concentration of naturally occurring radionuclides (U, Th and K) in the samples and their surroundings. The TL ages of the shards were found to range between 330±21 years and 920±69 years, indicative of the last firing of the bricks and tiles from which the shards originated, some dating back to the period during which the historical complex remained active. - Highlights: • Thermoluminescence analysis of shards sample from Pengkalan Bujang. • Fine grain technique and additive dose method were applied to determine paleodose. • Measuring concentration of U, Th and K in the samples and their surroundings. • TL ages obtained indicative of the last firing of the shards.

  14. Thermoluminescence of double fluorides doped with rare earths; Termoluminiscencia de fluoruros dobles dopados con tierras raras

    Energy Technology Data Exchange (ETDEWEB)

    Azorin N, J.; Sanchez R, A. [UAM-I, 09340 Mexico D.F. (Mexico); Khaidukov, N.M. [Kurnakov Institute of General and Inorganic Chemistry, 119991 Moscow (Russian Federation)

    2004-07-01

    In this work the thermoluminescent characteristics of double fluorides K{sub 2}YF{sub 5}, K{sub 2}GdF{sub 5} and K{sub 2}LuF{sub 5} doped are presented with Tb{sup 3+}, studied in the interval of temperature from 30 to 400 C. The materials that presented better answer to the irradiation with particles beta and with ultraviolet light they were the K{sub 2}YF{sub 5}: Tb (1% at. Tb{sup 3+}) and the K{sub 2}LuF{sub 5}: Tb (1% at. Tb{sup 3+}); while the K{sub 2}YF{sub 5}: Tb to high concentrations (10% and 20% at. Tb{sup 3+}) and the K{sub 2}LuF{sub 5}: Tb (1% at. Tb{sup 3+}) and the K{sub 2}LuF{sub 5}: Tb (1% at. Tb{sup 3+}) they presented an acceptable answer in front of the gamma radiation. The intensity of the Tl answer induced in these materials is a decisive factor to continue studying its dosimetric characteristics, what allows to consider them as the base for the development of potential materials to use them in the dosimetry of beta particles, of the UV light of the gamma radiation using the thermoluminescence method. (Author)

  15. Thermoluminescence study of aluminium oxide doped germanium prepared by combustion synthesis method

    Directory of Open Access Journals (Sweden)

    Saharin Nurul Syazlin Binti

    2017-01-01

    Full Text Available The present paper reports the optimum concentration of germanium (Ge dopant in aluminium oxide (AhO3 samples prepared by combustion synthesis (CS method for thermoluminescence (TL studies. The samples were prepared at various Ge concentration i.e. 1 to 5% mol. The phase formation of un-doped and Ge-doped Al2O3 samples was determined using X-ray Diffraction (XRD. The sharp peaks present in the XRD pattern confirms the crystallinity of the samples. The samples were then exposed to 50 Gy Cobalt-60 sources (Gamma cell 220. TL glow curves were measured and recorded using a Harshaw Model 3500 TLD reader. Comparison of TL peaks were observed to obtain the best composition of Ge dopants. A simple glow curves TL peak at around 175̊C for all composition samples was observed. It was also found that the composition of aluminium oxide doped with 3.0% of germanium exhibits the highest thermoluminescence (TL intensity which is 349747.04 (a.u.

  16. Thermoluminescent properties of nanocrystalline ZnTe thin films: Structural and morphological studies

    Science.gov (United States)

    Rajpal, Shashikant; Kumar, S. R.

    2018-04-01

    Zinc Telluride (ZnTe) is a binary II-VI direct band gap semiconducting material with cubic structure and having potential applications in different opto-electronic devices. Here we investigated the effects of annealing on the thermoluminescence (TL) of ZnTe thin films. A nanocrystalline ZnTe thin film was successfully electrodeposited on nickel substrate and the effect of annealing on structural, morphological, and optical properties were studied. The TL emission spectrum of as deposited sample is weakly emissive in UV region at ∼328 nm. The variation in the annealing temperature results into sharp increase in emission intensity at ∼328 nm along with appearance of a new peak at ∼437 nm in visible region. Thus, the deposited nanocrystalline ZnTe thin films exhibited excellent thermoluminescent properties upon annealing. Furthermore, the influence of annealing (annealed at 400 °C) on the solid state of ZnTe were also studied by XRD, SEM, EDS, AFM. It is observed that ZnTe thin film annealed at 400 °C after deposition provide a smooth and flat texture suited for optoelectronic applications.

  17. La datation par thermoluminescence face à la production d’un nouveau type de faux

    Directory of Open Access Journals (Sweden)

    Isabelle Gerardy

    2009-04-01

    Full Text Available La thermoluminescence a été utilisée depuis plus de 30 ans pour évaluer l’ancienneté de certains échantillons archéologiques. Depuis plusieurs années, certains faussaires essayent de tromper le test en utilisant différentes techniques telles que l’irradiation artificielles de poteries récentes ou la réutilisation de tessons anciens pour fabriquer des faux présentant un signal de TL. Toute fois, certaines techniques telles que la recherche de traces d’enfouissement par binoculaire et l’analyse stylistique permettent de mettre les faux à jour.The thermoluminescence phenomenon has been use since more than 30 years to evaluate the age of certain archaeological samples. Since a couple of year, some try to pass over this test using different techniques like the artificial irradiation of recent objects or the re-use of some pieces of ancient potteries to manufacture object showing a real TL signal. Fortunately, some other analysis techniques like binocular observation or an analyse of the object style are able to distinguish true from false.  

  18. Synthesis and thermoluminescence properties of rare earth-doped NaMgBO3 phosphor.

    Science.gov (United States)

    Khan, Z S; Ingale, N B; Omanwar, S K

    2016-05-01

    Rare earth (Dy(3+) and Sm(3+))-doped sodium magnesium borate (NaMgBO3) is synthesized by solution combustion synthesis method keeping their thermoluminescence properties in mind. The reaction produced very stable crystalline NaMgBO3:RE (RE = Dy(3+), Sm(3+)) phosphors. The phosphors are exposed to (60)Co gamma-ray radiations dose of varying rate from 5 to 25 Gy, and their TL characteristics with kinetic parameters are studied. NaMgBO3:Dy(3+) phosphor shows two peaks for lower doping concentration of Dy(3+) while it reduced to single peak for the higher concentrations of activator Dy(3+). NaMgBO3:Dy(3+) shows the major glow peak around 200 °C while NaMgBO3:Sm(3+) phosphors show two well-separated glow peaks at 200 and 332 °C respectively. The thermoluminescence intensity of these phosphors was compare with the commercially available TLD-100 (Harshaw) phosphor. The TL responses for gamma-ray radiations dose were found to be linear from 5 to 25 Gy for both phosphors while the fading in each case is calculated for the tenure of 45 days.

  19. Thermoluminescence studies of the thermal and radiation histories of chondritic meteorites

    International Nuclear Information System (INIS)

    Melcher, C.L.

    1980-01-01

    The thermoluminescence properties of chondritic meteorites are investigated to understand the ways in which the stored TL reflects the thermal and radiation histories of these objects. Differences in TL levels measured in recent falls are attributed to small differences in orbital temperatures. In addition, a correlation between TL level and terrestrial age is observed in meteorites of known terrestrial age. The thermoluminescence in chondrites is produced primarily by ionization from galactic cosmic rays with a much smaller contribution from the decay of natural radionuclides (U, Th, K, Rb). The production of most of the TL occurs after the break up of the large parent bodies into meter-size objects which are thus exposed to the ionizing effects of the cosmic rays. Measurements indicate that the low temperature TL represents a dynamic equilibrium between build up from ionizing radiation and thermal draining. The high temperature TL is near saturation. The terrestrial ages currently of greatest interest are those of the recently discovered meteorites in Antarctica. TL measurements were made on 11 of these meteorites and compared with the activities of 14 C, 26 Al, and 36 Cl measured by other workers in terrestrial age studies. A good correlation was found between the TL levels and the activities of cosmogenic radionuclides in these meteorites. Since the TL measurements can be made more rapidly and require much smaller samples (approx. 10 mg) than the radionuclide measurements, TL is most useful as a screening process to select potentially interesting samples for further study by more precise techniques

  20. Modified ferrous ammonium sulfate benzoic acid xyelenol orange (MFBX) and thermoluminescent dosimeters - a comparative study

    International Nuclear Information System (INIS)

    Brindha, S.; Rose, J.V.R.; Sathyan, S.; Singh, Rabi Raja I.; Ravindran, B. Paul

    2002-01-01

    Radiation dosimetry deals with the determination of absorbed dose to the medium exposed to ionizing radiation. Chemical dosimetry depends on oxidation or reduction of chemicals by ionizing radiation. A ferrous ammonium sulfate benzoic acid xyelenol orange (FBX) dosimeter based on this principle is being used as a clinical dosimeter at present. Certain modifications were carried out in the preparation and storage of the FBX dosimeter to increase its shelf life. The resulting dosimeter was called a modified FBX (MFBX) dosimeter and has been used in our department for the past few years. An extensive study of the dose, dose rate and energy response of the dosimeter was carried out and compared with a thermoluminescent (LiF 7 ) dosimeter. The results obtained were found to be comparable to the thermoluminescent (LiF 7 ) dosimeter. Hence it was concluded that the MFBX dosimeter could be used for phantom dosimetry, data collection and in vivo measurements. Easier preparation and availability of the reagents are added advantages of using MFBX as a clinical dosimeter in small radiotherapy departments. (author)

  1. Analysis of the deconvolution of the thermoluminescent curve of the zirconium oxide doped with graphite

    International Nuclear Information System (INIS)

    Salas C, P.; Estrada G, R.; Gonzalez M, P.R.; Mendoza A, D.

    2003-01-01

    In this work, we present a mathematical analysis of the behavior of the thermoluminescent curve (Tl) induced by gamma radiation in samples made of zirconium oxide doped with different amounts of graphite. In accordance with the results gamma radiation induces a Tl curve with two maximum of emission localized in the temperatures at 139 and 250 C, the area under the curve is increasing as a function of the time of exposition to the radiation. The analysis of curve deconvolution, in accordance with the theory which indicates that this behavior must be obey a Boltzmann distribution, we found that each one of them has a different growth velocity as the time of exposition increase. In the same way, we observed that after the irradiation was suspended each one of the maximum decrease with different velocity. The behaviour observed in the samples is very interesting because the zirconium oxide has attracted the interest of many research groups, this material has demonstrated to have many applications in thermoluminescent dosimetry and it can be used in the quantification of radiation. (Author)

  2. Dose Measurements on the BION-M1 satellite applying passive detector packages

    Science.gov (United States)

    Stradi, Andrea; Berger, Thomas; Kodaira, Satoshi; Kubancak, Jan; Palfalvi, Jozsef K.; Ambrozova, Iva; Tolochek, Raisa; Shurshakov, Vyacheslav; Szabo, Julianna

    A passive detector package was developed in the past years in the Centre for Energy Research, Hungarian Academy of Science to detect cosmic ray particles, to determine their flux and dose. It consists of thermoluminescent detectors (TLD) and plastic solid state nuclear track detectors (SSNTD). In the frame of a scientific co-operation between the Institute for Biomedical Problems (IBMP) fourteen packages were flow within the new BION-M1 satellite program together with biological samples and detector packages from other participants. Two packages were located outside and the rest ones inside the recoverable capsule. Comparing to the previous BION and similar FOTON experiments, (all together 17 successful ones), this flight was a “champion” with the highest altitude (575 km), orbital inclination (64.9°) and flight duration (30 days). The external exposure provided a unique possibility to study not only the elevated level of cosmic rays but also the behavior of the detector packages in extreme circumstances as low temperature and pressure. The paper will summarize the construction of the detector packages, the calibration and evaluation processes, as well as, the linear energy transfer (LET) spectra, the absorbed dose and the mean quality factor. These quantities will be compared taking into consideration their location inside and outside the capsule and to the results of other participants. Also some comparison of results to the previous BION and FOTON flights and contemporary measurements on the ISS will be presented.

  3. Barrier Infrared Detector (BIRD)

    Data.gov (United States)

    National Aeronautics and Space Administration — A recent breakthrough in MWIR detector design, has resulted in a high operating temperature (HOT) barrier infrared detector (BIRD) that is capable of spectral...

  4. Simulating detectors dead time

    International Nuclear Information System (INIS)

    Rustom, Ibrahim Farog Ibrahim

    2015-06-01

    Nuclear detectors are used in all aspects of nuclear measurements. All nuclear detectors are characterized by their dead time i.e. the time needed by a detector to recover from a previous incident. A detector dead time influences measurements taken by a detector and specially when measuring high decay rate (>) where is the detector dead time. Two models are usually used to correct for the dead time effect: the paralayzable and the non-paralayzable models. In the current work we use Monte Carlo simulation techniques to simulate radioactivity and the effect of dead time and the count rate of a detector with a dead time =5x10 - 5s assuming the non-paralayzable model. The simulation indicates that assuming a non -paralayzable model could be used to correct for decay rate measured by a detector. The reliability of the non-paralayzable model to correct the measured decay rate could be gauged using the Monte Carlo simulation. (Author)

  5. The LDC detector concept

    Indian Academy of Sciences (India)

    ), the large detector concept (LDC) is being developed. The main points of the LDC are a large volume gaseous tracking system, combined with high precision vertex detector and an extremely granular calorimeter. The main design force ...

  6. Forward tracking detectors

    Indian Academy of Sciences (India)

    Abstract. Forward tracking is an essential part of a detector at the international linear collider (ILC). The requirements for forward tracking are explained and the proposed solutions in the detector concepts are shown.

  7. Thermal kinetic inductance detector

    Science.gov (United States)

    Cecil, Thomas; Gades, Lisa; Miceli, Antonio; Quaranta, Orlando

    2016-12-20

    A microcalorimeter for radiation detection that uses superconducting kinetic inductance resonators as the thermometers. The detector is frequency-multiplexed which enables detector systems with a large number of pixels.

  8. Gerenciamento de Projetos em Pesquisa e Desenvolvimento

    Directory of Open Access Journals (Sweden)

    Mauro Maia Laruccia

    2013-01-01

    Full Text Available Este trabalho tem por objetivo estudar o gerenciamento de projetos na área de Pesquisa e Desenvolvimento, em um cenário onde os avanços da tecnologia têm influenciado nas mais diversas áreas do conhecimento humano e passaram a exigir abordagens diferenciadas na forma de planejar, executar e controlar os projetos, para assegurar os resultados almejados pelas organizações. Avaliar as formas de conhecimento aplicadas ao gerenciamento de projetos e as interações de suas disciplinas apresenta-se como uma condição oportuna para compreensão e melhoria do processo de gerenciamento de projetos. Considerando que a interdisciplinaridade destaca-se na crítica e na busca de respostas aos limites do conhecimento e que rompe com o paradigma disciplinar de produção do conhecimento particionado, a análise da forma de conhecimento do gerenciamento de projetos pode contribuir para desvelar oportunidades e engendrar melhorias neste processo. Verifica-se que o gerenciamento de projeto tem evoluído continuamente e congrega diversas disciplinas do conhecimento nos modelos praticados. Atualmente, um dos modelos mais consagrados de gerenciamento de projetos é o Project Management Body of Knowledge (PMBOK, publicado pelo Project Management Institute (PMI, que é utilizado em mais de 185 países. Vale ressaltar, que a simples comunicação entre as disciplinas do gerenciamento de projetos não significa que estejamos aplicando necessariamente uma abordagem interdisciplinar. Analisar o gerenciamento de projetos na ótica da interdisciplinaridade pode contribuir para o aperfeiçoamento dos modelos de gerenciamento de projetos e consequentemente para a geração de melhores resultados para as organizações.DOI:10.5585/gep.v3i3.82

  9. The LDC detector concept

    Indian Academy of Sciences (India)

    2004. Its goal is to design a complete detector concept for the LDC, based on a gaseous central tracking detector, and on granular calorimetry. The concept is heavily based on the concept of particle flow for event reconstruction. LDC started from the TESLA detector, developed for the TESLA TDR [2] and published in 2001.

  10. Gas filled detectors

    International Nuclear Information System (INIS)

    Stephan, C.

    1993-01-01

    The main types of gas filled nuclear detectors: ionization chambers, proportional counters, parallel-plate avalanche counters (PPAC) and microstrip detectors are described. New devices are shown. A description of the processes involved in such detectors is also given. (K.A.) 123 refs.; 25 figs.; 3 tabs

  11. The CAPRICE RICH detector

    International Nuclear Information System (INIS)

    Basini, G.; De Pascale, M.P.; Golden, R.L.; Barbiellini, G.; Boezio, M.

    1995-01-01

    A compact RICH detector has been developed and used for particle identification in a balloon borne spectrometer to measure the flux of antimatter in the cosmic radiation. This is the first RICH detector ever used in space experiments that is capable of detecting unit charged particles, such as antiprotons. The RICH and all other detectors performed well during the 27 hours long flight

  12. The LDC detector concept

    Indian Academy of Sciences (India)

    and an extremely granular calorimeter. The main design force behind the LDC is the particle flow concept. Keywords. International linear collider; large detector concept. PACS No. 13.66-a. 1. Introduction. The large detector concept (LDC) detector concept group [1] was formed early in. 2004. Its goal is to design a complete ...

  13. The CAPRICE RICH detector

    Energy Technology Data Exchange (ETDEWEB)

    Basini, G. [INFN, Laboratori Nazionali di Frascati, Rome (Italy); Codino, A.; Grimani, C. [Perugia Univ. (Italy)]|[INFN, Perugia (Italy); De Pascale, M.P. [Rome Univ. `Tor Vergata` (Italy). Dip. di Fisica]|[INFN, Sezione Univ. `Tor Vergata` Rome (Italy); Cafagna, F. [Bari Univ. (Italy)]|[INFN, Bari (Italy); Golden, R.L. [New Mexico State Univ., Las Cruces, NM (United States). Particle Astrophysics Lab.; Brancaccio, F.; Bocciolini, M. [Florence Univ. (Italy)]|[INFN, Florence (Italy); Barbiellini, G.; Boezio, M. [Trieste Univ. (Italy)]|[INFN, Trieste (Italy)

    1995-09-01

    A compact RICH detector has been developed and used for particle identification in a balloon borne spectrometer to measure the flux of antimatter in the cosmic radiation. This is the first RICH detector ever used in space experiments that is capable of detecting unit charged particles, such as antiprotons. The RICH and all other detectors performed well during the 27 hours long flight.

  14. Development of a nano structured system based on zirconia and Co nanoparticles for thermoluminescent applications: sensor of gamma and UV radiation

    International Nuclear Information System (INIS)

    Villa S, G.

    2014-01-01

    Powders of zirconium IV oxide as well as systems composed of zirconia nano crystals and cobalt nanoparticles (ZrO 2 :NPCo) with dimensions of nanometers were synthesized by the sol-gel method. Zirconia and ZrO 2 :NPCo systems have crystalline structure tetragonal or monoclinic is the heat treatment was to 500 and 1000 degrees Celsius respectively. The characterization of the synthesized materials consisted of a morphological and structural analysis, the information obtained was correlated to its thermoluminescent response induced by gamma and ultraviolet radiation. Thermoluminescent behavior was analyzed on different concentrations of cobalt nanoparticles incorporated during the synthesis process of the zirconium oxide. The monoclinic structure has the highest sensitivity thermoluminescent induced by ultraviolet and gamma radiation. Moreover, the thermoluminescence intensity decreased considerably in ZrO 2 :NPCo systems and was induced the growth of a glow peak at 280 degrees Celsius. In most of the materials analyzed the relation of the thermoluminescence intensity depending the time of irradiation with ultraviolet light showed the saturation of the traps in the material after 60 s of irradiation. Using gamma radiation is observed a behavior linear in the applied dose range between 0.25 Gy and 450 Gy. The growth of a glow peak at 280 degrees Celsius is the most important change in the thermoluminescence characteristics of zirconia. The ZrO 2 :NPCo systems can be used in the development of thermoluminescent dosimeters for detecting gamma radiation fields mainly. (Author)

  15. Application of numerical analysis methods to thermoluminescence dosimetry; Aplicacion de metodos de analisis numerico a la dosimetria por termoluminiscencia

    Energy Technology Data Exchange (ETDEWEB)

    Gomez Ros, J. M.; Delgado, A.

    1989-07-01

    This report presents the application of numerical methods to thermoluminescence dosimetry (TLD), showing the advantages obtained over conventional evaluation systems. Different configurations of the analysis method are presented to operate in specific dosimetric applications of TLD, such as environmental monitoring and mailed dosimetry systems for quality assurance in radiotherapy facilities. (Author) 10 refs.

  16. Issues in the reconstruction of environmental doses on the basis of thermoluminescence measurements in the Techa riverside

    Science.gov (United States)

    Bougrov, N. G.; Goksu, H. Y.; Haskell, E.; Degteva, M. O.; Meckbach, R.; Jacob, P.; Neta, P. I. (Principal Investigator)

    1998-01-01

    The potential of thermoluminescence measurements of bricks from the contaminated area of the Techa river valley, Southern Urals, Russia, for reconstructing external exposures of affected population groups has been studied. Thermoluminescence dating of background samples was used to evaluate the age of old buildings available on the river banks. The anthropogenic gamma dose accrued in exposed samples is determined by subtracting the natural radiation background dose for the corresponding age from the accumulated dose measured by thermoluminescence. For a site in the upper Techa river region, where the levels of external exposures were extremely high, the depth-dose distribution in bricks and the dependence of accidental dose on the height of the sampling position were determined. For the same site, Monte Carlo simulations of radiation transport were performed for different source configurations corresponding to the situation before and after the construction of a reservoir on the river and evacuation of the population in 1956. A comparison of the results provides an understanding of the features of the measured depth-dose distributions and height dependencies in terms of the source configurations and shows that bricks from the higher sampling positions are likely to have accrued a larger fraction of anthropogenic dose from the time before the construction of the reservoir. The applicability of the thermoluminescent dosimetry method to environmental dose reconstruction in the middle Techa region, where the external exposure was relatively low, was also investigated.

  17. Thermoluminescence dating of chinese porcelain using a regression method of saturating exponential in pre-dose technique

    International Nuclear Information System (INIS)

    Wang Weida; Xia Junding; Zhou Zhixin; Leung, P.L.

    2001-01-01

    Thermoluminescence (TL) dating using a regression method of saturating exponential in pre-dose technique was described. 23 porcelain samples from past dynasties of China were dated by this method. The results show that the TL ages are in reasonable agreement with archaeological dates within a standard deviation of 27%. Such error can be accepted in porcelain dating

  18. Analysis of thermoluminescence kinetics of Mg2SiO4:Tb compounds employing an interactive model

    International Nuclear Information System (INIS)

    Marcazzo, J.; Prokic, M.; Santiago, M.; Molina, P.; Caselli, E.

    2009-01-01

    The kinetics involved in the thermoluminescence (TL) of Mg 2 SiO 4 :Tb compounds has been investigated by unfolding glow curves employing both the General Order model and a model that takes into account interactions among traps. The dependence of the glow curve shape on dose is only correctly described if interaction among traps is included in the analysis.

  19. Thermoluminescent properties of undoped and Ce-doped lutetium orthosilicate and yttrium orthosilicate single crystals and single crystalline films scintillators

    Czech Academy of Sciences Publication Activity Database

    Twardak, A.; Bilski, B.; Zorenko, Yu.; Zorenko, T.; Gorbenko, V.; Mandowska, E.; Mandowski, A.; Sidletskiy, O.; Mareš, Jiří A.

    2014-01-01

    Roč. 61, č. 1 (2014), s. 276-281 ISSN 0018-9499 Institutional support: RVO:68378271 Keywords : LSO * single crystalline films * single crystals * thermoluminescence * YSO Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.283, year: 2014

  20. Dose measurements in dental radiology using thermoluminescent dosimetry;Medicoes de dose em radiodiagnostico odontologico utilizando dosimetria termoluminescente

    Energy Technology Data Exchange (ETDEWEB)

    Chiara, Ana Claudia M. de; Costa, Alessandro M. [Universidade de Sao Paulo (FFCLRP/USP), Ribeirao Preto, SP (Brazil). Faculdade de Filosofia, Ciencias e Letras; Pardini, Luiz Carlos [Universidade de Sao Paulo (FORP/USP), Ribeirao Preto, SP (Brazil). Faculdade de Odontologia

    2009-07-01

    The aim of this work was the implementation of a code of practice for dosimetry in dental radiology using the technique of thermoluminescent dosimetry. General principles for the use of thermoluminescent dosimeters were followed. The irradiations were performed using ten X-ray equipment for intra-oral radiography and an X-ray equipment for panoramic radiography. The incident air kerma was evaluated for five different exposure times used in clinical practice for intra-oral radiographs. Using a backscatter factor of 1.2, it was observed that approximately 40% of the entrance skin dose values found for intra-oral radiographs are above the diagnostic reference level recommended in national regulation. Different configurations of voltage and current were used representing the exposure as a child, woman and man for panoramic radiographs. The results obtained for the air kerma area product were respectively 53.3 +- 5.2 mGy.cm{sup 2}, 101.5 +- 9.5 mGy.cm{sup 2} and 116.8 +- 10.4 mGy.cm{sup 2}. The use of thermoluminescent dosimetry requires several procedures before a result is recorded. The use of dosimeters with ionization chambers or semiconductors provides a simple and robust method for routine measurements. However, the use of thermoluminescent dosimetry can be of great value to large-scale surveys to establish diagnostic reference levels. (author)