WorldWideScience

Sample records for thermography twelve breast

  1. Thermography in the follow-up of breast cancer patients after breast-conserving treatment by tumorectomy and radiation therapy

    International Nuclear Information System (INIS)

    Ulmer, H.U.; Brinkmann, M.; Frischbier, H.J.

    1990-01-01

    It is often suggested in the literature that thermography is able to diagnose a recurrence in the breast after breast-conserving therapy by a rise in breast temperature much earlier than other diagnostic tools, but no thermographic values are presented. The thermographic data of a prospective study of 309 women after breast-conserving therapy were evaluated. Seventeen of these women had an intramammary recurrence. A total of 2432 individual measured values were evaluated from 292 patients without evidence of a recurrence and 146 measured values from 17 patients with intramammary recurrence. The thermographic behavior of the breast after breast-conserving therapy is not uniform. However, the breast temperatures of the patients with intramammary recurrences were not significantly different from those without recurrences. This means that thermography is of no value in the care after breast-conserving therapy

  2. Applicability of active infrared thermography for screening of human breast: a numerical study

    Science.gov (United States)

    Dua, Geetika; Mulaveesala, Ravibabu

    2018-03-01

    Active infrared thermography is a fast, painless, noncontact, and noninvasive imaging method, complementary to mammography, ultrasound, and magnetic resonance imaging methods for early diagnosis of breast cancer. This technique plays an important role in early detection of breast cancer to women of all ages, including pregnant or nursing women, with different sizes of breast, irrespective of either fatty or dense breast. This proposed complementary technique makes use of infrared emission emanating from the breast. Emanating radiations from the surface of the breast under test are detected with an infrared camera to map the thermal gradients over it, in order to reveal hidden tumors inside it. One of the reliable active infrared thermographic technique, linear frequency modulated thermal wave imaging is adopted to detect tumors present inside the breast. Further, phase and amplitude images are constructed using frequency and time-domain data analysis schemes. Obtained results show the potential of the proposed technique for early diagnosis of breast cancer in fatty as well as dense breasts.

  3. Computer simulation in conjunction with medical thermography as an adjunct tool for early detection of breast cancer

    Directory of Open Access Journals (Sweden)

    Sudharsan NM

    2004-04-01

    Full Text Available Abstract Background Mathematical modelling and analysis is now accepted in the engineering design on par with experimental approaches. Computer simulations enable one to perform several 'what-if' analyses cost effectively. High speed computers and low cost of memory has helped in simulating large-scale models in a relatively shorter time frame. The possibility of extending numerical modelling in the area of breast cancer detection in conjunction with medical thermography is considered in this work. Methods Thermography enables one to see the temperature pattern and look for abnormality. In a thermogram there is no radiation risk as it only captures the infrared radiation from the skin and is totally painless. But, a thermogram is only a test of physiology, whereas a mammogram is a test of anatomy. It is hoped that a thermogram along with numerical modelling will serve as an adjunct tool. Presently mammogram is the 'gold-standard' in breast cancer detection. But the interpretation of a mammogram is largely dependent on the radiologist. Therefore, a thermogram that looks into the physiological changes in combination with numerical simulation performing 'what-if' analysis could act as an adjunct tool to mammography. Results The proposed framework suggested that it could reduce the occurrence of false-negative/positive cases. Conclusion A numerical bioheat model of a female breast is developed and simulated. The results are compared with experimental results. The possibility of this method as an early detection tool is discussed.

  4. Computer simulation in conjunction with medical thermography as an adjunct tool for early detection of breast cancer

    International Nuclear Information System (INIS)

    Ng, Eddie Y-K; Sudharsan, NM

    2004-01-01

    Mathematical modelling and analysis is now accepted in the engineering design on par with experimental approaches. Computer simulations enable one to perform several 'what-if' analyses cost effectively. High speed computers and low cost of memory has helped in simulating large-scale models in a relatively shorter time frame. The possibility of extending numerical modelling in the area of breast cancer detection in conjunction with medical thermography is considered in this work. Thermography enables one to see the temperature pattern and look for abnormality. In a thermogram there is no radiation risk as it only captures the infrared radiation from the skin and is totally painless. But, a thermogram is only a test of physiology, whereas a mammogram is a test of anatomy. It is hoped that a thermogram along with numerical modelling will serve as an adjunct tool. Presently mammogram is the 'gold-standard' in breast cancer detection. But the interpretation of a mammogram is largely dependent on the radiologist. Therefore, a thermogram that looks into the physiological changes in combination with numerical simulation performing 'what-if' analysis could act as an adjunct tool to mammography. The proposed framework suggested that it could reduce the occurrence of false-negative/positive cases. A numerical bioheat model of a female breast is developed and simulated. The results are compared with experimental results. The possibility of this method as an early detection tool is discussed

  5. Evaluation of dynamic infrared thermography as an alternative to CT angiography for perforator mapping in breast reconstruction: a clinical study

    International Nuclear Information System (INIS)

    Weum, Sven; Mercer, James B.; Weerd, Louis de

    2016-01-01

    The current gold standard for preoperative perforator mapping in breast reconstruction with a DIEP flap is CT angiography (CTA). Dynamic infrared thermography (DIRT) is an imaging method that does not require ionizing radiation or contrast injection. We evaluated if DIRT could be an alternative to CTA in perforator mapping. Twenty-five patients scheduled for secondary breast reconstruction with a DIEP flap were included. Preoperatively, the lower abdomen was examined with hand-held Doppler, DIRT and CTA. Arterial Doppler sound locations were marked on the skin. DIRT examination involved rewarming of the abdominal skin after a mild cold challenge. The locations of hot spots on DIRT were compared with the arterial Doppler sound locations. The rate and pattern of rewarming of the hot spots were analyzed. Multiplanar CT reconstructions were used to see if hot spots were related to perforators on CTA. All flaps were based on the perforator selected with DIRT and the surgical outcome was analyzed. First appearing hot spots were always associated with arterial Doppler sounds and clearly visible perforators on CTA. The hot spots on DIRT images were always slightly laterally located in relation to the exit points of the associated perforators through the rectus abdominis fascia on CTA. Some periumbilical perforators were not associated with hot spots and showed communication with the superficial inferior epigastric vein on CTA. The selected perforators adequately perfused all flaps. This study confirms that perforators selected with DIRT have arterial Doppler sound, are clearly visible on CTA and provide adequate perfusion for DIEP breast reconstruction. Retrospectively registered at ClinicalTrials.gov with identifier NCT02806518

  6. Infrared thermography

    CERN Document Server

    Meola, Carosena

    2012-01-01

    This e-book conveys information about basic IRT theory, infrared detectors, signal digitalization and applications of infrared thermography in many fields such as medicine, foodstuff conservation, fluid-dynamics, architecture, anthropology, condition monitoring, non destructive testing and evaluation of materials and structures.

  7. Single Jejunum Metastasis from Breast Cancer Arising Twelve Years after the Initial Treatment

    Directory of Open Access Journals (Sweden)

    Cláudia Paiva

    2016-01-01

    Full Text Available Metastatic involvement of gastrointestinal tract from breast cancer is a rare event. We report the case of a 61-year-old woman presenting with bowel obstruction, related to metastasis of a primary breast cancer she had 12 years earlier (a triple-negative invasive ductal carcinoma treated with surgery and chemotherapy. Bowel obstruction was caused by a 20-centimeter tumor in the jejunum, involving also the transverse colon. The patient underwent en bloc resection of tumor with jejunum and transverse bowel segment and received adjuvant chemotherapy with carboplatin and paclitaxel. Twenty months later, she was alive without disease recurrence.

  8. Thermography colloquium 2017. Abstracts; Thermographie-Kolloquium 2017. Vortraege

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2017-07-01

    This volume contains 23 papers on the following main topics: 1. Inductive thermography, 2. Laser thermography, 3. Thermography on fiber composites, 4. Simulation and equipment technology, 5. Optical properties and building thermography. [German] Dieser Band enthaelt 23 Beitraege zu folgenden Themenschwerpunkten: 1. Induktive Thermographie, 2. Laser-Thermographie, 3. Thermographie an Faserverbundwerkstoffen, 4. Simulation und Geraetetechnik, 5. Optische Eigenschaften und Bauthermographie.

  9. Screening for breast cancer in a high-risk series

    International Nuclear Information System (INIS)

    Woodard, E.D.; Hempelmann, L.H.; Janus, J.; Logan, W.; Dean, P.

    1982-01-01

    A unique cohort of women at increased risk of breast cancer because of prior X-ray treatment of acute mastitis and their selected high-risk siblings were offered periodic breast cancer screening including physical examination of the breasts, mammography, and thermography. Twelve breast cancers were detected when fewer than four would have been expected based on age-specific breast cancer detection rates from the National Cancer institute/American Cancer Society Breast Cancer Demonstration Detection Projects. Mammograpy was positive in all cases but physical examination was positive in only three cases. Thermography was an unreliable indicator of disease. Given the concern over radiation-induced risk, use of low-dose technique and of criteria for participation that select women at high risk of breast cancer will maximize the benefit/risk ratio for mammography screening

  10. Changes in concentrations of perfluorinated compounds, polybrominated diphenyl ethers, and polychlorinated biphenyls in Norwegian breast-milk during twelve months of lactation.

    Science.gov (United States)

    Thomsen, Cathrine; Haug, Line S; Stigum, Hein; Frøshaug, May; Broadwell, Sharon L; Becher, Georg

    2010-12-15

    At present, scientific knowledge on depuration rates of persistent organic pollutants (POPs) is limited and the previous assumptions of considerable reduction of body burdens through breast-feeding have recently been challenged. We therefore studied elimination rates of important POPs in nine Norwegian primiparous mothers and one mother breast-feeding her second child by collecting breast-milk samples (n = 70) monthly from about two weeks to up to twelve months after birth. Perfluorinated compounds (PFCs), polybrominated diphenyl ethers (PBDEs), hexabromocyclododecane (HBCD), and polychlorinated biphenyls (PCBs) were determined in the breast-milk samples. Linear mixed effect models were established for selected compounds, and significant decreases in the range of 1.2-4.7% in breast-milk concentrations per month were observed for a wide range of PCBs and PBDEs. For the first time, depuration rates for perfluorooctylsulfonate (PFOS) and perfluorooctanoic acid (PFOA) are presented, being 3.8 and 7.8% per month, respectively (p changes during the lactation period. After a year of nursing the breast-milk concentrations of PFCs, PBDEs, and PCBs were reduced by 15-94%.

  11. Infrared thermography of loose hangingwalls

    CSIR Research Space (South Africa)

    Kononov, VA

    2002-09-01

    Full Text Available This project is the continuation of GAP706 “Pre-feasibility investigation of infrared thermography for the identification of loose hangingwall and impending falls of ground”. The main concept behind the infrared thermography method...

  12. Thermography colloquium 2015. Abstracts; Thermographie-Kolloquium 2015. Vortraege

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2015-07-01

    The USB stick contains 17 lectures which where held on the Thermography colloquium 2015 in Leinfelden-Echterdingen (Germany). Here a selection of the topics: Thermal Chladni sound figures in nondestructive testing (M. Rahammer); Flash thermography with several flashes (R. Krankenhagen); Frequency optimization of ultrasound-induced thermography during the measurement (C. Srajbr); Worldwide introduction of a thermographic inspection system for gas turbine components (M. Goldammer); Practical aspects of automation of thermographic weld inspection (G.Mahler); Investigations to determine the crack depth with inductive thermography (B. Oswald-Tranta); Testing of spot welds with laser thermography (M. Ziegler).

  13. Matched-Filter Thermography

    Directory of Open Access Journals (Sweden)

    Nima Tabatabaei

    2018-04-01

    Full Text Available Conventional infrared thermography techniques, including pulsed and lock-in thermography, have shown great potential for non-destructive evaluation of broad spectrum of materials, spanning from metals to polymers to biological tissues. However, performance of these techniques is often limited due to the diffuse nature of thermal wave fields, resulting in an inherent compromise between inspection depth and depth resolution. Recently, matched-filter thermography has been introduced as a means for overcoming this classic limitation to enable depth-resolved subsurface thermal imaging and improving axial/depth resolution. This paper reviews the basic principles and experimental results of matched-filter thermography: first, mathematical and signal processing concepts related to matched-fileting and pulse compression are discussed. Next, theoretical modeling of thermal-wave responses to matched-filter thermography using two categories of pulse compression techniques (linear frequency modulation and binary phase coding are reviewed. Key experimental results from literature demonstrating the maintenance of axial resolution while inspecting deep into opaque and turbid media are also presented and discussed. Finally, the concept of thermal coherence tomography for deconvolution of thermal responses of axially superposed sources and creation of depth-selective images in a diffusion-wave field is reviewed.

  14. Thermography by Infrared

    International Nuclear Information System (INIS)

    Harara, W.; Allouch, Y.; Altahan, A.

    2015-08-01

    This study focused on the principle’s explanation of metallic components and structures testing by thermography method using infrared waves. The study confirmed that, thermal waves testing technique as one of the most important method among the modern non-destructive testing methods. It is characterized by its economy, easy to apply and timely testing of components and metallic structures. This method is applicable to a wide variety of components such as testing pieces of planes, power plants, electric transmission lines and aerospace components, in order to verify their structures and fabrication quality and their comformance to the international standards.Testing the components by thermography using infrared radiation is easy and rapid if compared to other NDT methods. The study included an introduction to the thermography testing method, its equipements, components and the applied technique. Finally, two practical applications are given in order to show the importance of this method in industry concerned with determining the liquid level in a tank and testing the stability of the control box of electrical supply.(author)

  15. Thermography without training

    International Nuclear Information System (INIS)

    Rahne, E.

    2009-01-01

    In the recent years more and more times and in more and more areas (fields) can we hear about thermography applications. These are mostly building-energetical, electrical and mechanical condition monitoring and human-biological applications. Thousands of termocameras are used in Hungary, but the knowledge of the operators and the analyzers is neither controlled nor qualified by any professional organization. In Hungary there is no THERMOGRAPH profession or recognized and claimed exam, this way the market is uncontrolled. This study mentioned the theoretical basics, the practical point of view, the current situation in Hungary and the foreign situation. (S.I.)

  16. Thermography. Principles and measurements; Thermographie. Principes et mesure

    Energy Technology Data Exchange (ETDEWEB)

    Pajani, D. [Ecole Centrale de Lyon, 69 - Ecully (France)

    2001-09-01

    Thermography is a technique which allows to obtain the thermal image of a given scene and for a determined spectral domain. Infrared thermography is the most well-known and used technique of thermography, but this article deals with the thermographic measurements in general and for a wider part of the radiation spectrum: 1 - general considerations: terminology, fluxes and temperatures measurement; 2 - radiations (emission and reception), radiative properties of materials: basic notions, simplified radiometer, radiative properties of materials; 3 - thermographic measurements: general considerations, calibration, radiometric measurement situation, from the radiometric measurement to the thermometric measurement and to the thermographic measurement, measurement uncertainties. (J.S.)

  17. Infrared thermography in veterinary medicine

    International Nuclear Information System (INIS)

    Hudak, R.; Zivcak, J.; Sevcik, A.; Danko, J.

    2008-01-01

    The use of infrared thermography in veterinary medicine has been practiced since at least the 1960's, but it is only now, in approximately the last 5 years, that it has been viewed with a reasonably open mind in the veterinary community at large. One of the reasons is progress in sensors technology, which contributed for an outstanding improvement of the thermal imager parameters. Paper deals with veterinary thermography and with description of applications at the University of Veterinary Medicine in Kosice. (authors)

  18. Thermography for health care

    International Nuclear Information System (INIS)

    Bagavathiappan, S.; Saravanan, T.; Philip, John; Jayakumar, T.; Raj, Baldev; Karunanithi, R.; Panicker, T.M.R.; Paul Korath, M.; Jagadeesan, K.

    2009-01-01

    Body temperature is a very useful parameter for diagnosing diseases. Often there is a definite correlation between body temperature and diseases. We have used infrared thermography to carry out non-invasive diagnosis of peripheral vascular diseases. Temperature gradients are observed in the affected regions of patients with vascular disorders, which indicate abnormal blood flow in the affected region. Thermal imaging results are well correlated with the clinical findings. Certain areas on the affected limbs showed increased temperature profiles, due to inflammation and underlying venues flow changes. In general, the temperature contrast in the affected regions is about 0.7 to 1 deg C above the normal regions, due to sluggish blood circulation. The results suggest that the thermal imaging technique is an effective technique for detecting small temperature changes in human body due to vascular disorders. (author)

  19. Application of Thermography in Ukraine

    Directory of Open Access Journals (Sweden)

    Venger, Ye.F.

    2015-11-01

    Full Text Available The review presents the results of applying the thermography for the tumor diagnosis, vertebral pain of athletes, vascular lesions, joint trauma, maxillofacial pathology, the study of the mechanism of pathogenic effects of the battery in a biologically active environment, the study of heterogeneity of thermal fields of newborns’ incubators, modeling the propagation of pollutants in ecology. Based on its own developments domestic industry ensured the production of thermal imaging devices to solve military problems. A large and varied use of thermal imaging thermography in Ukraine leads to the conclusion that in the coming years thermal imaging will get overall development.

  20. The twelve colourful stones

    International Nuclear Information System (INIS)

    Doria, R.M.

    1983-01-01

    A dynamics with twelve colourful stones is created based on the concepts of gauge and colour. It is associated different gauge fields to the same group. A group of gauge invariant Lagrangians is established. A gauge invariant mass term is introduced. The colourful stones physical insight is to be building blocks for quarks and leptons. (Author) [pt

  1. The twelve colourful stones

    International Nuclear Information System (INIS)

    Doria, R.M.

    1984-01-01

    The gauge symmetry is extended. It is associated differents matter and gauge fields to the same group. A group of gauge invariant Lagrangians is established. A gauge invariant mass term is introduced. A massive Yang Mills is obtained. A dynamics with twelve colourful stones is created based on the concepts of gauge and colour. Structures identified as quarks and leptons are generated. A discussion about colour meaning is presented. (Author) [pt

  2. Therminological problems in medical thermography

    International Nuclear Information System (INIS)

    Rozenfel'd, L.G.; Kolotilov, N.N.

    1988-01-01

    Some problems of medicotechnical terminology of clinical thermography are discussed. A short hystorical review of stages of the recovery of infrared rays and their medical application was given. An analysis of a number of terms is based on the rules of medical terminology and state standards. An obligatory use in literature of correct terms, mainly of the Greek and Latin origin, is proposed. Commonly used terms on the basis of modern anatomical terminology are recommended for thermogram description

  3. Therminological problems in medical thermography

    Energy Technology Data Exchange (ETDEWEB)

    Rozenfel' d, L G; Kolotilov, N N

    1988-01-01

    Some problems of medicotechnical terminology of clinical thermography are discussed. A short hystorical review of stages of the recovery of infrared rays and their medical application was given. An analysis of a number of terms is based on the rules of medical terminology and state standards. An obligatory use in literature of correct terms, mainly of the Greek and Latin origin, is proposed. Commonly used terms on the basis of modern anatomical terminology are recommended for thermogram description.

  4. Defect detection using transient thermography

    International Nuclear Information System (INIS)

    Mohd Zaki Umar; Ibrahim Ahmad; Ab Razak Hamzah; Wan Saffiey Wan Abdullah

    2008-08-01

    An experimental research had been carried out to study the potential of transient thermography in detecting sub-surface defect of non-metal material. In this research, eight pieces of bakelite material were used as samples. Each samples had a sub-surface defect in the circular shape with different diameters and depths. Experiment was conducted using one-sided Pulsed Thermal technique. Heating of samples were done using 30 kWatt adjustable quartz lamp while infra red (IR) images of samples were recorded using THV 550 IR camera. These IR images were then analysed with ThermofitTMPro software to obtain the Maximum Absolute Differential Temperature Signal value, ΔΤ m ax and the time of its appearance, τ m ax (ΔΤ). Result showed that all defects were able to be detected even for the smallest and deepest defect (diameter = 5 mm and depth = 4 mm). However the highest value of Differential Temperature Signal (ΔΤ m ax), were obtained at defect with the largest diameter, 20 mm and at the shallowest depth, 1 mm. As a conclusion, the sensitivity of the pulsed thermography technique to detect sub-surface defects of bakelite material is proportionately related with the size of defect diameter if the defects are at the same depth. On the contrary, the sensitivity of the pulsed thermography technique inversely related with the depth of defect if the defects have similar diameter size. (Author)

  5. Medical applications of infrared thermography: A review

    Science.gov (United States)

    Lahiri, B. B.; Bagavathiappan, S.; Jayakumar, T.; Philip, John

    2012-07-01

    Abnormal body temperature is a natural indicator of illness. Infrared thermography (IRT) is a fast, passive, non-contact and non-invasive alternative to conventional clinical thermometers for monitoring body temperature. Besides, IRT can also map body surface temperature remotely. Last five decades witnessed a steady increase in the utility of thermal imaging cameras to obtain correlations between the thermal physiology and skin temperature. IRT has been successfully used in diagnosis of breast cancer, diabetes neuropathy and peripheral vascular disorders. It has also been used to detect problems associated with gynecology, kidney transplantation, dermatology, heart, neonatal physiology, fever screening and brain imaging. With the advent of modern infrared cameras, data acquisition and processing techniques, it is now possible to have real time high resolution thermographic images, which is likely to surge further research in this field. The present efforts are focused on automatic analysis of temperature distribution of regions of interest and their statistical analysis for detection of abnormalities. This critical review focuses on advances in the area of medical IRT. The basics of IRT, essential theoretical background, the procedures adopted for various measurements and applications of IRT in various medical fields are discussed in this review. Besides background information is provided for beginners for better understanding of the subject.

  6. Twelve years at DESY

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    As reported in our previous issue (page 27), on 28 February Volker Soergel stepped down after serving as Chairman of the Board of the DESY Laboratory in Hamburg since January 1981, when the previous chairman, Herwig Schopper, moved to become Director General of CERN. DESY is now headed by Bjorn Wiik. During the twelve years of Soergel's mandate, DESY substantially evolved and progressed. Dominating the landscape was the big HERA electron-proton collider - the world's first - proposed, approved, constructed and commissioned under Soergel's leadership. As well as pioneering electron-proton collisions, HERA also broke new ground in international collaboration. At the approval of the project by the German government, it had already been made clear that both the machine and its experiments had to be built with full international cooperation, using material contributions from foreign institutes. With the difficult task of transforming these requirements into hard reality, Volker Soergel succeeded brilliantly. The 'HERA model', with interested countries pledging contributions in equipment and/or manpower, established a new route to major project involvement. For HERA, the substantial Italian contribution, organized by Antonino Zichichi, was vital to the success of the project

  7. Wearable device for skin contact thermography: design, construction and testing

    International Nuclear Information System (INIS)

    Giansanti, D.; Maccioni, G.

    2008-01-01

    The need for wearable devices for thermal monitoring is rising. These devices could be used to continuously monitor patients for breast cancer investigation or vascular, dermatological and rheumatic disorders, in viability studies, or during physical exercise. We designed and constructed a wearable device for skin-contact thermography that uses integrated silicon sensors. The device was validated using a phantom with a dynamic bench test. The thermal resolution was greater than 0.030'C, and the spatial resolution was equal to 1.6x10-5 m'2. We also investigated the device's performance on five clinical subjects. Results of these studies showed a maximal error of less than 0.10'C in each evaluation [it

  8. Thermography colloquium 2007; Thermografie-Kolloquium 2007

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-07-01

    The CD contains 16 contributions, mostly in the form of manuscripts or summaries, and two posters on the following subjects: 1. Environmental influences affecting the accuracy of building thermography (G. Dittie, Dittie Thermografie, Koenigswinter). 2. Energetic modernisation of older buildings: BlowerDoor inspection and IR thermography as decision aids for modernisation measures (K. Schwarz, Beratender Ingenieur, Ingenieurbuero Schwarz, Owingen / Baden). 3. Gas leak detection in the oil and gas industry using infrared optical imaging (J. Tegstam, FLIR Systems AB, Danderyd, Sweden; et al.). 4. The Medical Use of Infrared-Thermography; History and Recent Applications (R. Berz, Deutsche Gesellschaft fuer Thermographie und Regulationsmedizin, Hilders / Rhoen; et al.). 5. Dual-Band-QWIP IR Camera ''Geminis 110k ML'' Technology and applications (O. Schreer, IRCAM, Erlangen; et al.). 6. Quantitative Phase and Amplitude Evaluation in the Active Thermography Frequency Range using Rectangular Pulse Heating (R. Arndt, BAM Berlin; et al.). 8. Spatially resolved detection of fatigue processes in metals using IR thermography (J. Medgenberg, TU Braunschweig, Institut fuer Bauwerkserhaltung und Tragwerk, Braunschweig, et al.). 9. Active thermography for analysis of transport processes (C.S. Garbe, IWR und IUR, Universitaet Heidelberg et al.). 10. Frequency optimisation of ultrasonic thermography methods (C. Spiessberger, Institut fuer Kunststofftechnik (IKT), Universitaet Stuttgart et al.). 11. Detection of cracks near the tooths of toothed gears using thermography and eddy current testing (W. Reimche, Leibniz Universitaet Hannover, Garbsen et al.). 12. Spatially resolved solar cell characterisation using Lock-in thermography (K. Ramspeck, Institut fuer Solarenergieforschung, Hameln / Emmerthal et al.). 14. Puls-Phase Thermography of CFRPL components with defined damage and repair (T. Krell, WIWEB, Erding et al.). 15. Depth-resolved defect detection using

  9. Thermography of network in Estonia

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-05-01

    The overall objective of environmental energy sector programmes is to reduce dependency on unsafe nuclear power stations and also to reduce the environmental impact of the energy sector by means of improved energy efficiency, increased use of cleaner technology and cleaner energy sources. In order to ensure sustainability during the reorganisation of the energy sector, support must be provided for organisational development as well as for training and education. The programmes cover both suppliers and consumers. This paper concludes that IR thermography is an excellent performance control method for district heating networks: A biannual or annual inspection gives a good impression of the general condition of the network; Digging costs will be reduced through precise location of any defects; It will be easier to decide the exact timing of any repairs or renovation, leading to improved purchase options; If sudden water losses occur, IR technology can be applied for quick location; It is essential that operators receive very thorough training, and that close attention is paid to qualifications and references when selecting operators. Resources must be made available for individual training in the field, Where trainee operators are given responsibility for completing their own assignments under the supervisoon of experienced operators. (EG)

  10. Infrared thermography quantitative image processing

    Science.gov (United States)

    Skouroliakou, A.; Kalatzis, I.; Kalyvas, N.; Grivas, TB

    2017-11-01

    Infrared thermography is an imaging technique that has the ability to provide a map of temperature distribution of an object’s surface. It is considered for a wide range of applications in medicine as well as in non-destructive testing procedures. One of its promising medical applications is in orthopaedics and diseases of the musculoskeletal system where temperature distribution of the body’s surface can contribute to the diagnosis and follow up of certain disorders. Although the thermographic image can give a fairly good visual estimation of distribution homogeneity and temperature pattern differences between two symmetric body parts, it is important to extract a quantitative measurement characterising temperature. Certain approaches use temperature of enantiomorphic anatomical points, or parameters extracted from a Region of Interest (ROI). A number of indices have been developed by researchers to that end. In this study a quantitative approach in thermographic image processing is attempted based on extracting different indices for symmetric ROIs on thermograms of the lower back area of scoliotic patients. The indices are based on first order statistical parameters describing temperature distribution. Analysis and comparison of these indices result in evaluating the temperature distribution pattern of the back trunk expected in healthy, regarding spinal problems, subjects.

  11. Narrative review: Diabetic foot and infrared thermography

    Science.gov (United States)

    Hernandez-Contreras, D.; Peregrina-Barreto, H.; Rangel-Magdaleno, J.; Gonzalez-Bernal, J.

    2016-09-01

    Diabetic foot is one of the major complications experienced by diabetic patients. An early identification and appropriate treatment of diabetic foot problems can prevent devastating consequences such as limb amputation. Several studies have demonstrated that temperature variations in the plantar region can be related to diabetic foot problems. Infrared thermography has been successfully used to detect complication related to diabetic foot, mainly because it is presented as a rapid, non-contact and non-invasive technique to visualize the temperature distribution of the feet. In this review, an overview of studies that relate foot temperature with diabetic foot problems through infrared thermography is presented. Through this research, it can be appreciated the potential of infrared thermography and the benefits that this technique present in this application. This paper also presents the different methods for thermogram analysis and the advantages and disadvantages of each one, being the asymmetric analysis the method most used so far.

  12. Thermography detection on the fatigue damage

    Science.gov (United States)

    Yang, Bing

    It has always been a great temptation in finding new methods to in-situ "watch" the material fatigue-damage processes so that in-time reparations will be possible, and failures or losses can be minimized to the maximum extent. Realizing that temperature patterns may serve as fingerprints for stress-strain behaviors of materials, a state-of-art infrared (IR) thermography camera has been used to "watch" the temperature evolutions of both crystalline and amorphous materials "cycle by cycle" during fatigue experiments in the current research. The two-dimensional (2D) thermography technique records the surface-temperature evolutions of materials. Since all plastic deformations are related to heat dissipations, thermography provides an innovative method to in-situ monitor the heat-evolution processes, including plastic-deformation, mechanical-damage, and phase-transformation characteristics. With the understanding of the temperature evolutions during fatigue, thermography could provide the direct information and evidence of the stress-strain distribution, crack initiation and propagation, shear-band growth, and plastic-zone evolution, which will open up wide applications in studying the structural integrity of engineering components in service. In the current research, theoretical models combining thermodynamics and heat-conduction theory have been developed. Key issues in fatigue, such as in-situ stress-strain states, cyclic softening and hardening observations, and fatigue-life predictions, have been resolved by simply monitoring the specimen-temperature variation during fatigue. Furthermore, in-situ visulizations as well as qualitative and quantitative analyses of fatigue-damage processes, such as Luders-band evolutions, crack propagation, plastic zones, and final fracture, have been performed by thermography. As a method requiring no special sample preparation or surface contact by sensors, thermography provides an innovative and convenient method to in-situ monitor

  13. Development Of Economic Techniques For Residential Thermography

    Science.gov (United States)

    Allen, Lee R.; Allen, Sharon

    1983-03-01

    Infrared thermography has proven to be a valuable tool in the detection of heat loss in both commercial and residential buildings. The field of residential thermography has needed a simple method with which to report the deficiencies found during an infrared scan. Two major obstacles hindering the cost effectiveness of residential thermography have been 1) the ability to quickly transport some high resolution imaging system equipment from job site to job site without having to totally dismount the instruments at each area, and 2) the lack of a standard form with which to report the findings of the survey to the customer. Since the industry has yet to provide us with either, we believed it necessary to develop our own. Through trial and error, we have come up with a system that makes interior residential thermography a profitable venture at a price the homeowner can afford. Insulation voids, or defects can be instantly spotted with the use of a thermal imaging system under the proper conditions. A special hand-held device was developed that enables the thermographer to carry the equipment from house to house without the need to dismantle and set up at each stop. All the necessary components are attached for a total weight of about 40 pounds. The findings are then conveyed to a form we have developed. The form is simple enough that the client without special training in thermography can understand. The client is then able to locate the problems and take corrective measures or give it to a con-tractor to do the work.

  14. Development of NDE Technique with Induction Heating and Thermography on Conductive Composite Materials

    National Research Council Canada - National Science Library

    Shepard, Steven M; Lhota, James R; Ahmed, Tasdiq; Kim, HeeJune; Yarlagadda, Shridhar

    2004-01-01

    .... Our expectation at the outset of the projects was that the combination of induction heating and thermography would outperform systems based exclusively on either electromagnetic induction or thermography...

  15. Exit Presentation: Infrared Thermography on Graphite/Epoxy

    Science.gov (United States)

    Comeaux, Kayla

    2010-01-01

    This slide presentation reports on the internship project that was accomplished during the summer of 2010. The objectives of the project were to: (1) Simulate Flash Thermography on Graphite/Epoxy Flat Bottom hole Specimen and thin void specimens, (2) Obtain Flash Thermography data on Graphite/Epoxy flat bottom hole specimens, (3) Compare experimental results with simulation results, Compare Flat Bottom Hole Simulation with Thin Void Simulation to create a graph to determine size of IR Thermography detected defects

  16. Challenges to Global Implementation of Infrared Thermography Technology: Current Perspective

    OpenAIRE

    Michael Shterenshis

    2017-01-01

    Medical infrared thermography (IT) produces an image of the infrared waves emitted by the human body as part of the thermoregulation process that can vary in intensity based on the health of the person. This review analyzes recent developments in the use of infrared thermography as a screening and diagnostic tool in clinical and nonclinical settings, and identifies possible future routes for improvement of the method. Currently, infrared thermography is not considered to be a fully reliable d...

  17. Challenges to Global Implementation of Infrared Thermography Technology: Current Perspective.

    Science.gov (United States)

    Shterenshis, Michael

    2017-01-01

    Medical infrared thermography (IT) produces an image of the infrared waves emitted by the human body as part of the thermoregulation process that can vary in intensity based on the health of the person. This review analyzes recent developments in the use of infrared thermography as a screening and diagnostic tool in clinical and nonclinical settings, and identifies possible future routes for improvement of the method. Currently, infrared thermography is not considered to be a fully reliable diagnostic method. If standard infrared protocol is established and a normative database is available, infrared thermography may become a reliable method for detecting inflammatory processes.

  18. Challenges to Global Implementation of Infrared Thermography Technology: Current Perspective

    Directory of Open Access Journals (Sweden)

    Michael Shterenshis

    2017-10-01

    Full Text Available Medical infrared thermography (IT produces an image of the infrared waves emitted by the human body as part of the thermoregulation process that can vary in intensity based on the health of the person. This review analyzes recent developments in the use of infrared thermography as a screening and diagnostic tool in clinical and nonclinical settings, and identifies possible future routes for improvement of the method. Currently, infrared thermography is not considered to be a fully reliable diagnostic method. If standard infrared protocol is established and a normative database is available, infrared thermography may become a reliable method for detecting inflammatory processes.

  19. Crack imaging by pulsed laser spot thermography

    International Nuclear Information System (INIS)

    Li, T; Almond, D P; Rees, D A S; Weekes, B

    2010-01-01

    A surface crack close to a spot heated by a laser beam impedes lateral heat flow and produces alterations to the shape of the thermal image of the spot that can be monitored by thermography. A full 3D simulation has been developed to simulate heat flow from a laser heated spot in the proximity of a crack. The modelling provided an understanding of the ways that different parameters affect the thermal images of laser heated spots. It also assisted in the development of an efficient image processing strategy for extracting the scanned cracks. Experimental results show that scanning pulsed laser spot thermography has considerable potential as a remote, non-contact crack imaging technique.

  20. Application of infrared thermography in sports science

    CERN Document Server

    2017-01-01

    This book addresses the application of infrared thermography in sports, examining the main benefits of this non-invasive, non-radiating and low-cost technique. Aspects covered include the detection of injuries in sports medicine, the assessment of sports performance due to the existing link between physical fitness and thermoregulation and the analysis of heat transfer for sports garments and sports equipment. Although infrared thermography is broadly considered to be a fast and easy-to-use tool, the ability to deliver accurate and repeatable measurements is an important consideration. Furthermore, it is important to be familiar with the latest sports studies published on this technique to understand its potential and limitations. Accordingly, this book establishes a vital link between laboratory tests and the sports field. .

  1. NDT of railway components using induction thermography

    Science.gov (United States)

    Netzelmann, U.; Walle, G.; Ehlen, A.; Lugin, S.; Finckbohner, M.; Bessert, S.

    2016-02-01

    Induction or eddy current thermography is used to detect surface cracks in ferritic steel. The technique is applied to detect surface cracks in rails from a moving test car. Cracks were detected at a train speed between 2 and 15 km/h. An automated demonstrator system for testing railway wheels after production is described. While the wheel is rotated, a robot guides the detection unit consisting of inductor and infrared camera over the surface.

  2. Using Thermography in Classification of Plants in Greenhouses

    DEFF Research Database (Denmark)

    Hansen, J. Fly

    2008-01-01

      The objective of this paper is to describe how thermography can be used to make almost invisible parts of plants visible. The technique is based on using differences in the heat capacity together with thermography. The aim of the project described here is to examine the possibility of automated...

  3. Computerized detection of breast cancer with artificial intelligence and thermograms.

    Science.gov (United States)

    Ng, E Y-K; Fok, S C; Peh, Y C; Ng, F C; Sim, L S J

    2002-01-01

    This paper shows the concurrent use of thermography and artificial neural networks (ANN) for the diagnosis of breast cancer, a disease that is growing in prominence in women all over the world. It has been reported that breast thermography itself could detect breast cancer up to 10 years earlier than the conventional golden methods such as mammography, in particular in the younger patient. However, the accuracy of thermography is dependent on many factors such as the symmetry of the breasts' temperature and temperature stability. A woman's body temperature is known to be stable in certain periods after menstruation and it was found that the accuracy of thermography in women whose thermal images are taken in a suitable period (5th - 12th and 21st day of menstruation) is higher (80%) than the total population of patients (73%). The stability of the body temperature will depend on physiological state. This paper examines the use of ANN to complement the infrared heat radiating from the surface of the body with other physiological data. Four backpropagation neural networks were developed and trained using the results from the Singapore General Hospital patients' physiological data and thermographs. Owing to the inaccuracies found in thermography and the low population size gathered for this project, the networks developed could only accurately diagnose about 61.54% of the breast cancer cases. Nevertheless, the basic neural network framework has been established and it has great potential for future development of an intelligent breast cancer diagnosis system. This would be especially useful to the teenagers and young adults who are unsuitable for mammography at a young age. An intelligent breast thermography-neural network will be able to give an accurate diagnosis of breast cancer and can make a positive impact on breast disease detection.

  4. A protocol for analysing thermal stress in insects using infrared thermography.

    Science.gov (United States)

    Gallego, Belén; Verdú, José R; Carrascal, Luis M; Lobo, Jorge M

    2016-02-01

    The study of insect responses to thermal stress has involved a variety of protocols and methodologies that hamper the ability to compare results between studies. For that reason, the development of a protocol to standardize thermal assays is necessary. In this sense, infrared thermography solves some of the problems allowing us to take continuous temperature measurements without handling the individuals, an important fact in cold-blooded organisms like insects. Here, we present a working protocol based on infrared thermography to estimate both cold and heat thermal stress in insects. We analyse both the change in the body temperature of individuals and their behavioural response. In addition, we used partial least squares regression for the statistical analysis of our data, a technique that solves the problem of having a large number of variables and few individuals, allowing us to work with rare or endemic species. To test our protocol, we chose two species of congeneric, narrowly distributed dung beetles that are endemic to the southeastern part of the Iberian Peninsula. With our protocol we have obtained five variables in the response to cold and twelve in the response to heat. With this methodology we discriminate between the two flightless species of Jekelius through their thermal response. In response to cold, Jekelius hernandezi showed a higher rate of cooling and reached higher temperatures of stupor and haemolymph freezing than Jekelius punctatolineatus. Both species displayed similar thermoregulation ranges before reaching lethal body temperature with heat stress. Overall, we have demonstrated that infrared thermography is a suitable method to assess insect thermal responses with a high degree of sensitivity, allowing for the discrimination between closely related species. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Clinical relevance of hormone receptors in breast cancer diagnosis

    International Nuclear Information System (INIS)

    Knapstein, P.

    1981-01-01

    After an outline of the epidemiology of breast cancer, risk factors such as age, family history, ethnic factors, environmental effects, pregnancy, and hormonal factors are presented. The most efficient methods of early detection are palpation, mammography, and xeroradiography, although repeated mammography involves a risk of tumour induction. Further methods not suited for screeening are puncture cytology and thermography, of which the latter often yields wrong findings. New ways of mass screening may be found in sonography and microwave thermography. (MG) [de

  6. Fast infrared thermography on the COMPASS tokamak.

    Czech Academy of Sciences Publication Activity Database

    Vondráček, Petr; Gauthier, C.; Ficker, Ondřej; Hron, Martin; Imríšek, Martin; Pánek, Radomír

    2017-01-01

    Roč. 123, November (2017), s. 764-767 ISSN 0920-3796. [SOFT 2016: Symposium on Fusion Technology /29./. Prague, 05.09.2016-09.09.2016] R&D Projects: GA MŠk(CZ) 8D15001; GA MŠk(CZ) LM2015045; GA ČR(CZ) GA15-10723S EU Projects: European Commission(XE) 633053 - EUROfusion Institutional support: RVO:61389021 Keywords : Infrared thermography * Heat flux decay length * Runaway electrons * Sawtooth Subject RIV: JF - Nuclear Energetics OBOR OECD: Nuclear related engineering Impact factor: 1.319, year: 2016 http://www.sciencedirect.com/science/article/pii/S0920379617305392

  7. Infrared thermography for examination of paper structure

    Science.gov (United States)

    Kiiskinen, Harri T.; Pakarinen, Pekka I.

    1998-03-01

    The paper industry has used IR cameras primarily for troubleshooting, where the most common examples include the examination of the condition of dryer fabrics and dryer cylinders and the analysis of moisture variations in a paper web. Another application extensively using IR thermography is non-destructive testing of composite materials. This paper presents some recently developed laboratory methods using an IR camera to examine paper structure. Specific areas include cockling, moisture content, thermal uniformity, mechanism of failure, and an analysis of the copying process.

  8. Infrared thermography examination of paper structure

    International Nuclear Information System (INIS)

    Kiiskinen, H.T.; Kukkonen, H.K.; Pakarinen, P.I.; Laine, A.J.

    1997-01-01

    The paper industry has used IR cameras primarily for troubleshooting, where the most common examples include the examination of the condition of dryer fabrics and dryer cylinders and the analysis of moisture variations in a paper web. Another application extensively using IR thermography is non-destructive testing of composite materials. This paper presents some recently developed laboratory methods using an IR camera to examine paper structure. Specific areas include cockling, moisture content, thermal uniformity, mechanism of failure, and an analysis of the copying process. (author)

  9. Infrared thermography program at Darlington NGD

    International Nuclear Information System (INIS)

    Speer, B.

    1997-01-01

    Infrared thermography is a proven predictive maintenance tool for improving equipment reliability and reducing maintenance costs. It has been identified as one of the maintenance technologies that could contribute to the reduction of OHN forced incapability factor. At Darlington NGD a program has been established by combining OHN and Nuclear Maintenance Applications Center (NMAC) operating experience. This presentation outlines the development and implementation of this program. The main points are: roles and responsibilities, equipment selection, software requirements, manpower level, inspection equipment, training and a cost/benefit review. (author)

  10. Infrared thermography on TFR 600 Tokamak

    International Nuclear Information System (INIS)

    Romain, Roland.

    1980-06-01

    Infrared thermography with a single InSb detector and with a scanning camera has been performed on the TFR fusion device. High power neutral beam injection diagnostic by means of an infrared periscope is showed to be possible. Surface temperature measurements on the limiter during the discharge have been made in order to evaluate the power deposited by the plasma on this part of the inner wall. Various attempts of infrared detection on the high power neutral injector prototype vessel are described, particularly the measurement of the power deposited on one of the extraction grids of the ion source [fr

  11. Flash Infrared Thermography Contrast Data Analysis Technique

    Science.gov (United States)

    Koshti, Ajay

    2014-01-01

    This paper provides information on an IR Contrast technique that involves extracting normalized contrast versus time evolutions from the flash thermography inspection infrared video data. The analysis calculates thermal measurement features from the contrast evolution. In addition, simulation of the contrast evolution is achieved through calibration on measured contrast evolutions from many flat-bottom holes in the subject material. The measurement features and the contrast simulation are used to evaluate flash thermography data in order to characterize delamination-like anomalies. The thermal measurement features relate to the anomaly characteristics. The contrast evolution simulation is matched to the measured contrast evolution over an anomaly to provide an assessment of the anomaly depth and width which correspond to the depth and diameter of the equivalent flat-bottom hole (EFBH) similar to that used as input to the simulation. A similar analysis, in terms of diameter and depth of an equivalent uniform gap (EUG) providing a best match with the measured contrast evolution, is also provided. An edge detection technique called the half-max is used to measure width and length of the anomaly. Results of the half-max width and the EFBH/EUG diameter are compared to evaluate the anomaly. The information provided here is geared towards explaining the IR Contrast technique. Results from a limited amount of validation data on reinforced carbon-carbon (RCC) hardware are included in this paper.

  12. Experimental developments towards an ITER thermography diagnostic

    International Nuclear Information System (INIS)

    Reichle, R.; Brichard, B.; Escourbiac, F.; Gardarein, J.L.; Hernandez, D.; Le Niliot, C.; Rigollet, F.; Serra, J.J.; Badie, J.M.; van Ierschot, S.; Jouve, M.; Martinez, S.; Ooms, H.; Pocheau, C.; Rauber, X.; Sans, J.L.; Scheer, E.; Berghmans, F.; Decreton, M.

    2007-01-01

    In the course of the development of a concept for a spectrally resolving thermography diagnostic for the ITER divertor using optical fibres experimental development work has been carried out in three different areas. Firstly ZrF 4 fibres and hollow fibres (silica capillaries with internal AG/AgJ coating) were tested in a Co 60 irradiation facility under γ irradiation up to doses of 5 kGy and 27 kGy, respectively. The ZrF 4 fibres suffered more radiation induced degradation (>1 db/m) then the hollow fibres (0-0.4 db/m). Secondly multi-colour pyroreflectometry is being developed towards tokamak applicability. The emissivity and temperature of tungsten samples were measured in the range of 700-1500 o C. The angular working range for off normal observation of the method was 20-30 o . The working distance of the method has been be increased from cm to the m range. Finally, encouraging preliminary results have been obtained concerning the application of pulsed and modulated active thermography

  13. Breast

    International Nuclear Information System (INIS)

    Ribeiro, G.G.

    1985-01-01

    The treatment of malignant disease of the breast arouses more controversy and emotion than that of any other form of malignant disease. Many clinical trials have been carried out and others are still in progress. In addition, research work continues in regard to other aspects of the disease, such as epidemiology, population screening, and endocrine factors; yet little is really known about the true biological nature of carcinoma of the breast. A vast amount of literature has accumulated on the treatment of ''operable'' carcinoma of the breast, but it is not proposed to discuss here the merits or demerits of the various suggested treatments. Instead this chapter will be confined to the practical management of carcinoma of the breast as seen from the point of view of radiotherapist. For this reason greater attention will be paid to the radiotherapy techniques as practised at the Christie Hospital

  14. Transanal rectopexy - twelve case studies

    Directory of Open Access Journals (Sweden)

    Rubens Henrique Oleques Fernandes

    2012-06-01

    Full Text Available OBJECTIVES: This study analyzed the results of transanal rectopexy and showed the benefits of this surgical technique. METHOD: Twelve patients were submitted to rectopexy between 1997 and 2011. The surgical technique used was transanal rectopexy, where the mesorectum was fixed to the sacrum with nonabsorbable suture. Three patients had been submitted to previous surgery, two by the Delorme technique and one by the Thiersch technique. RESULTS: Postoperative hospital stay ranged from 1 to 4 days. One patient (8.3% had intraoperative hematoma, which was treated with local compression and antibiotics. One patient (8.3% had residual mucosal prolapse, which was resected. Prolapse recurrence was seen in one case (8.3%. Improved incontinence occurred in 75% of patients and one patient reported obstructed evacuation in the first month after surgery. No death occurred. CONCLUSION: Transanal rectopexy is a simple, low cost technique, which has shown good efficacy in rectal prolapse control.OBJETIVO: O presente estudo analisou os resultados da retopexia pela via transanal e expôs os benefícios desta técnica cirúrgica. MÉTODO: Doze pacientes com prolapso foram operados no período de 1997 a 2011. A técnica cirúrgica usada foi a retopexia transanal, onde o mesorreto foi fixado ao sacro com fio inabsorvível. Três pacientes tinham cirurgia prévia, dois pela técnica de Delorme e um pela técnica de Thiersch. RESULTADOS: A permanência hospitalar pós-operatória variou de 1- 4 dias. Uma paciente (8,3% apresentou hematoma transoperatório que foi tratado com compressão local e antibioticoterapia. Um paciente apresentou prolapso mucoso residual (8,3%, que foi ressecado. Houve recidiva da procidência em um caso (8,3%. A melhora da incontinência ocorreu em 75% dos pacientes e uma paciente apresentou bloqueio evacuatório no primeiro mês após a cirurgia. Não houve mortalidade entre os pacientes operados. CONCLUSÃO: A retopexia transanal é uma t

  15. Airborne thermography of temperature patterns in sugar beet piles

    Science.gov (United States)

    Moore, D. G.; Bichsel, S.

    1975-01-01

    An investigation was conducted to evaluate the use of thermography for locating spoilage areas (chimneys) within storage piles and to subsequently use the information for the scheduling of their processing. Thermal-infrared quantitative scanner data were acquired initially on January 16, 1975, over the storage piles at Moorhead, Minnesota, both during the day and predawn. Photographic data were acquired during the day mission to evaluate the effect of uneven snow cover on the thermal emittance, and the predawn thermography was used to locate potential chimneys. The piles were examined the day prior for indications of spoilage areas, and the ground crew indicated that no spoilage areas were located using their existing methods. Nine spoilage areas were interpreted from the thermography. The piles were rechecked by ground methods three days following the flights. Six of the nine areas delineated by thermography were actual spoilage areas.

  16. Infrared thermography for wood density estimation

    Science.gov (United States)

    López, Gamaliel; Basterra, Luis-Alfonso; Acuña, Luis

    2018-03-01

    Infrared thermography (IRT) is becoming a commonly used technique to non-destructively inspect and evaluate wood structures. Based on the radiation emitted by all objects, this technique enables the remote visualization of the surface temperature without making contact using a thermographic device. The process of transforming radiant energy into temperature depends on many parameters, and interpreting the results is usually complicated. However, some works have analyzed the operation of IRT and expanded its applications, as found in the latest literature. This work analyzes the effect of density on the thermodynamic behavior of timber to be determined by IRT. The cooling of various wood samples has been registered, and a statistical procedure that enables one to quantitatively estimate the density of timber has been designed. This procedure represents a new method to physically characterize this material.

  17. Mapping corrosion of metallic slab by thermography

    International Nuclear Information System (INIS)

    Bison, P; Ceseri, M; Inglese, G

    2010-01-01

    Thermography is used to detect corrosion on a aluminum specimen. Two identical aluminum plates are extracted from the same base material. One of them is machined on one side, in such a way to simulate a material loss. Both the sound and damaged plate are heated on the undamaged side by a sine modulated heating source. A thermographic camera records a sequence of images of the temperature surface of both the sound and damaged sample on the heated (undamaged) sides. Several sequences are recorded with different modulation periods. By a suitable data reduction procedure, the thermographic sequence is reduced to a couple of images representing amplitude and phase of the oscillating temperature field. A perturbative method is used to solve iteratively the direct problem in the corroded domain that is confronted with the experimental data until an optimum matching is reached.

  18. Convective heat transfer and infrared thermography.

    Science.gov (United States)

    Carlomagno, Giovanni M; Astarita, Tommaso; Cardone, Gennaro

    2002-10-01

    Infrared (IR) thermography, because of its two-dimensional and non-intrusive nature, can be exploited in industrial applications as well as in research. This paper deals with measurement of convective heat transfer coefficients (h) in three complex fluid flow configurations that concern the main aspects of both internal and external cooling of turbine engine components: (1) flow in ribbed, or smooth, channels connected by a 180 degrees sharp turn, (2) a jet in cross-flow, and (3) a jet impinging on a wall. The aim of this study was to acquire detailed measurements of h distribution in complex flow configurations related to both internal and external cooling of turbine components. The heated thin foil technique, which involves the detection of surface temperature by means of an IR scanning radiometer, was exploited to measure h. Particle image velocimetry was also used in one of the configurations to precisely determine the velocity field.

  19. A Review of Microwave Thermography Nondestructive Testing and Evaluation

    Directory of Open Access Journals (Sweden)

    Hong Zhang

    2017-05-01

    Full Text Available Microwave thermography (MWT has many advantages including strong penetrability, selective heating, volumetric heating, significant energy savings, uniform heating, and good thermal efficiency. MWT has received growing interest due to its potential to overcome some of the limitations of microwave nondestructive testing (NDT and thermal NDT. Moreover, during the last few decades MWT has attracted growing interest in materials assessment. In this paper, a comprehensive review of MWT techniques for materials evaluation is conducted based on a detailed literature survey. First, the basic principles of MWT are described. Different types of MWT, including microwave pulsed thermography, microwave step thermography, microwave pulsed phase thermography, and microwave lock-in thermography are defined and introduced. Then, MWT case studies are discussed. Next, comparisons with other thermography and NDT methods are conducted. Finally, the trends in MWT research are outlined, including new theoretical studies, simulations and modelling, signal processing algorithms, internal properties characterization, automatic separation and inspection systems. This work provides a summary of MWT, which can be utilized for material failures prevention and quality control.

  20. A Review of Microwave Thermography Nondestructive Testing and Evaluation.

    Science.gov (United States)

    Zhang, Hong; Yang, Ruizhen; He, Yunze; Foudazi, Ali; Cheng, Liang; Tian, Guiyun

    2017-05-15

    Microwave thermography (MWT) has many advantages including strong penetrability, selective heating, volumetric heating, significant energy savings, uniform heating, and good thermal efficiency. MWT has received growing interest due to its potential to overcome some of the limitations of microwave nondestructive testing (NDT) and thermal NDT. Moreover, during the last few decades MWT has attracted growing interest in materials assessment. In this paper, a comprehensive review of MWT techniques for materials evaluation is conducted based on a detailed literature survey. First, the basic principles of MWT are described. Different types of MWT, including microwave pulsed thermography, microwave step thermography, microwave pulsed phase thermography, and microwave lock-in thermography are defined and introduced. Then, MWT case studies are discussed. Next, comparisons with other thermography and NDT methods are conducted. Finally, the trends in MWT research are outlined, including new theoretical studies, simulations and modelling, signal processing algorithms, internal properties characterization, automatic separation and inspection systems. This work provides a summary of MWT, which can be utilized for material failures prevention and quality control.

  1. Optically and non-optically excited thermography for composites: A review

    Science.gov (United States)

    Yang, Ruizhen; He, Yunze

    2016-03-01

    Composites, such as glass fiber reinforced polymer (GFRP) and carbon fiber reinforced polymer (CFRP), and adhesive bonding are being increasingly used in fields of aerospace, renewable energy, civil and architecture, and other industries. Flaws and damages are inevitable during either fabrication or lifetime of composites structures or components. Thus, nondestructive testing (NDT) are extremely required to prevent failures and to increase reliability of composite structures or components in both manufacture and in-service inspection. Infrared thermography techniques including pulsed thermography, pulsed phase thermography, and lock-in thermography have shown the great potential and advantages. Besides conventional optical thermography, other sources such as laser, eddy current, microwave, and ultrasound excited thermography are drawing increasingly attentions for composites. In this work, a fully, in-depth and comprehensive review of thermography NDT techniques for composites inspection was conducted based on an orderly and concise literature survey and detailed analysis. Firstly, basic concepts for thermography NDT were defined and introduced, such as volume heating thermography. Next, the developments of conventional optic, laser, eddy current, microwave, and ultrasound thermography for composite inspection were reviewed. Then, some case studies for scanning thermography were also reviewed. After that, the strengths and limitations of thermography techniques were concluded through comparison studies. At last, some research trends were predicted. This work containing critical overview, detailed comparison and extensive list of references will disseminates knowledge between users, manufacturers, designers and researchers involved in composite structures or components inspection by means of thermography NDT techniques.

  2. The value of dynamic infrared thermography (DIRT) in perforatorselection and planning of free DIEP flaps.

    Science.gov (United States)

    de Weerd, Louis; Weum, Sven; Mercer, James B

    2009-09-01

    The aim of this paper is to evaluate dynamic infrared thermography (DIRT) as a technique to assist in preoperative perforator selection and planning of free deep inferior epigastric perforator (DIEP) flaps. Twenty-seven patients, scheduled for secondary autologous breast reconstruction with either a free DIEP flap or superficial inferior epigastric artery flap, were included in this prospective clinical study. Preoperative mapping of perforators was performed with a hand-held Doppler and DIRT. A multidetector computer tomography scan was additionally carried out in the last 8 patients. In 23 patients a DIEP flap was used. The perforator as selected from DIRT was a suitable perforator in all DIEP flaps. The location and quality of the selected perforator from DIRT corresponded well with the multidetector computer tomography scan results. Preoperative perforator selection and planning of DIEP flaps is facilitated with the use of DIRT. The technique is noninvasive and easy to use.

  3. Integrity Evaluation of Railway Bogie Using Infrared Thermography Technique

    International Nuclear Information System (INIS)

    Kim, Jeong Guk

    2011-01-01

    The lock-in thermography was employed to evaluate the integrity of railway bogies. Prior to the actual application on railway bogies, in order to assess the detectability of known flaws, the calibration reference panel was prepared with various dimensions of artificial flaws. The panel was composed of structural steel, which was the same material with actual bogies. Through lock-in thermography evaluation, the optimal frequency of heat source was determined for the best flaw detection. Based on the defects information, the actual defect assessments on railway bogie were conducted with different types of railway bogies, which were used for the current operation. In summary, the defect assessment results with thermography method showed a good agreement as compared with the conventional inspection techniques. Moreover, it was found that the novel infrared thermography technique could be an effective way for the inspection and the detection of surface defects on bogies since the infrared thermography method provided rapid and non-contact mode for the investigation of railway bogies

  4. A survey of phosphors novel for thermography

    Energy Technology Data Exchange (ETDEWEB)

    Bruebach, J., E-mail: bruebach@ekt.tu-darmstadt.d [Fachgebiet Reaktive Stroemungen und Messtechnik, Center of Smart Interfaces Technische Universitaet Darmstadt, Petersenstrasse 32, 64287 Darmstadt (Germany); Kissel, T. [Fachgebiet Reaktive Stroemungen und Messtechnik, Center of Smart Interfaces Technische Universitaet Darmstadt, Petersenstrasse 32, 64287 Darmstadt (Germany); Frotscher, M. [Eduard-Zintl-Institut fuer Anorganische und Physikalische Chemie, Technische Universitaet Darmstadt, Petersenstrasse 18, 64287 Darmstadt (Germany); Euler, M. [Fachgebiet Reaktive Stroemungen und Messtechnik, Center of Smart Interfaces Technische Universitaet Darmstadt, Petersenstrasse 32, 64287 Darmstadt (Germany); Albert, B. [Eduard-Zintl-Institut fuer Anorganische und Physikalische Chemie, Technische Universitaet Darmstadt, Petersenstrasse 18, 64287 Darmstadt (Germany); Dreizler, A. [Fachgebiet Reaktive Stroemungen und Messtechnik, Center of Smart Interfaces Technische Universitaet Darmstadt, Petersenstrasse 32, 64287 Darmstadt (Germany)

    2011-04-15

    With regard to phosphor thermometry, seven luminescent ceramic materials were synthesised and characterised, namely CaMoO{sub 4}:Eu{sup 3+}, CaTiO{sub 3}:Pr{sup 3+}, LaPO{sub 4}:Eu{sup 3+}, LaVO{sub 4}:Eu{sup 3+}, LiAl{sub 5}O{sub 8}:Fe{sup 3+}, TiMg{sub 2}O{sub 4}:Mn{sup 4+} and ZnGa{sub 2}O{sub 4}:Mn{sup 2+}. In this context, emission spectra and temperature lifetime characteristics are presented. Thus, a survey of phosphors novel for thermography is given in order to encourage further studies and more detailed characterisations of the respective materials. - Research Highlights: Seven phosphor materials novel for thermometry were synthesised. These materials were characterised diffractometrically as well as concerning their emission spectra and lifetime temperature characteristics. The number of phosphor materials characterised for thermometry purposes was extended by seven materials.

  5. Thermography hogging the limelight at Big Sky

    Energy Technology Data Exchange (ETDEWEB)

    Plastow, C. [Fluke Electronics Canada, Mississauga, ON (Canada)

    2010-02-15

    The high levels of humidity and ammonia found at hog farms can lead to premature corrosion of electrical systems and create potential hazards, such as electrical fires. Big Sky Farms in Saskatchewan has performed on-site inspections at its 44 farms and 16 feed mills using handheld thermography technology from Fluke Electronics. Ti thermal imaging units save time and simplify inspections. The units could be used for everything, from checking out the bearings at the feed mills to electrical circuits and relays. The Ti25 is affordable and has the right features for a preventative maintenance program. Operators of Big Sky Farms use the Ti25 to inspect all circuit breakers of 600 volts or lower as well as transformers where corrosion often causes connections to break off. The units are used to look at bearings, do scanning and thermal imaging on motors. To date, the Ti25 has detected and highlighted 5 or 6 problems on transformers alone that could have been major issues. At one site, the Ti25 indicated that all 30 circuit breakers had loose connections and were overeating. Big Sky Farms fixed the problem right away before a disaster happened. In addition to reducing inspection times, the Ti25 can record all measurements and keep a record of all the readings for downloading. 2 figs.

  6. Electromagnetic pulsed thermography for natural cracks inspection

    Science.gov (United States)

    Gao, Yunlai; Tian, Gui Yun; Wang, Ping; Wang, Haitao; Gao, Bin; Woo, Wai Lok; Li, Kongjing

    2017-01-01

    Emerging integrated sensing and monitoring of material degradation and cracks are increasingly required for characterizing the structural integrity and safety of infrastructure. However, most conventional nondestructive evaluation (NDE) methods are based on single modality sensing which is not adequate to evaluate structural integrity and natural cracks. This paper proposed electromagnetic pulsed thermography for fast and comprehensive defect characterization. It hybrids multiple physical phenomena i.e. magnetic flux leakage, induced eddy current and induction heating linking to physics as well as signal processing algorithms to provide abundant information of material properties and defects. New features are proposed using 1st derivation that reflects multiphysics spatial and temporal behaviors to enhance the detection of cracks with different orientations. Promising results that robust to lift-off changes and invariant features for artificial and natural cracks detection have been demonstrated that the proposed method significantly improves defect detectability. It opens up multiphysics sensing and integrated NDE with potential impact for natural understanding and better quantitative evaluation of natural cracks including stress corrosion crack (SCC) and rolling contact fatigue (RCF). PMID:28169361

  7. Thermography and thermoregulation of the face

    Directory of Open Access Journals (Sweden)

    Bremerich Andreas

    2007-03-01

    Full Text Available Abstract Background Although clinical diagnosis of thermoregulation is gaining in importance there is no consistent evidence on the value of thermography of the facial region. In particular there are no reference values established with standardised methods. Methods Skin temperatures were measured in the facial area at 32 fixed measuring sites in 26 health subjects (7–72 years with the aid of a contact thermograph (Eidatherm. A total of 6 measurements were performed separately for the two sides of the face at intervals of equal lengths (4 hours over a period of 24 hours. Thermoregulation was triggered by application of a cold stimulus in the region of the ipsilateral ear lobe. Results Comparison of the sides revealed significant asymmetry of face temperature. The left side of the face showed a temperature that was on the average 0.1°C lower than on the right. No increase in temperature was found following application of the cold stimulus. However, a significant circadian rhythm with mean temperature differences of 0.7°C was observed. Conclusion The results obtained should be seen as an initial basis for compiling an exact thermoprofile of the surface temperature of the facial region that takes into account the circadian rhythm, thus closing gaps in studies on physiological changes in the temperature of the skin of the face.

  8. Thermography and thermoregulation of the face

    Science.gov (United States)

    Rustemeyer, Jan; Radtke, Jürgen; Bremerich, Andreas

    2007-01-01

    Background Although clinical diagnosis of thermoregulation is gaining in importance there is no consistent evidence on the value of thermography of the facial region. In particular there are no reference values established with standardised methods. Methods Skin temperatures were measured in the facial area at 32 fixed measuring sites in 26 health subjects (7–72 years) with the aid of a contact thermograph (Eidatherm). A total of 6 measurements were performed separately for the two sides of the face at intervals of equal lengths (4 hours) over a period of 24 hours. Thermoregulation was triggered by application of a cold stimulus in the region of the ipsilateral ear lobe. Results Comparison of the sides revealed significant asymmetry of face temperature. The left side of the face showed a temperature that was on the average 0.1°C lower than on the right. No increase in temperature was found following application of the cold stimulus. However, a significant circadian rhythm with mean temperature differences of 0.7°C was observed. Conclusion The results obtained should be seen as an initial basis for compiling an exact thermoprofile of the surface temperature of the facial region that takes into account the circadian rhythm, thus closing gaps in studies on physiological changes in the temperature of the skin of the face. PMID:17362518

  9. Thermography applied acupuncture and qi-gong

    Science.gov (United States)

    Qin, Yuwen; Ji, Hong-Wei; Chen, Jin-Long; Li, Hong-Qi

    1997-04-01

    Thermographic technique can be used to measure temperature distribution of body surface in real-time, non-contact and full-field, which has been successfully used in medical diagnosis, remote sensing, and NDT, etc. The authors have developed a thermographic experiment that can be applied to inspect the effect of action of acupuncture and qi-gong (a system of deep breathing exercises) by measuring the temperature of hand and arm. The observation is performed respectively by thermography for the dynamic changes of temperature of the arm and hand after acupuncture therapy and qi-gong therapy. Thermographic results show that the temperature on the collateral channels increases markedly. In the meantime, it can be seen that the above therapies of Chinese medicine can stimulate the channel collateral system. This also contributes a new basis to the effect of action of the therapies of Chinese medicine. The work shows that thermographic technique is a powerful tool for research in Chinese medicine. In this paper, some thermal images are obtained from the persons treated with acupuncture and qi- gong.

  10. Thermography in the detection and follow up of chondromalacia patellae.

    Science.gov (United States)

    Vujcić, M; Nedeljković, R

    1991-01-01

    Although diagnostic criteria for chondromalacia patellae exist, the disease is often accompanied by physical signs which are limited or non-diagnostic. Thermographic examination was performed in 157 patients with clinical diagnosis of chondromalacia patellae in 86 patients after surgical treatment for chondromalacia, and in 308 controls. Thermography can help the clinicians in establishing the diagnosis of chondromalacia patellae, but by itself is not sufficiently specific. The specificity of thermography was dependent on age, ranging from 90% for the 15-24 year age group to 65% for the 45-54 year age group. Sensitivity of the method was 68%. Thermography can disclose other knee disorders which imitate chondromalacia patellae. Images PMID:1768161

  11. Pulsed Thermography Applied to the Study of Cultural Heritage

    Directory of Open Access Journals (Sweden)

    Fulvio Mercuri

    2017-09-01

    Full Text Available In this paper, an overview of the recent applications of pulsed infrared thermography is presented. Pulsed infrared thermography, which provides stratigraphic information by analyzing the heat diffusion process within the sample after a thermal perturbation, is applied to the investigation of different kinds of cultural heritage artefacts. In particular, it is used to analyze repairs, decorative elements, and casting faults on bronzes, to detect texts hidden or damaged in ancient books/documents, and to characterize paint decorations. Moreover, the integration of pulsed infrared thermography and three-dimensional shape recording methods is proposed in order to provide a three-dimensional representation of the thermographic results. Finally, it is shown how the obtained thermographic results may be crucial from the historical and artistic points of view for understanding the modus operandi of a specific artist and/or of a workshop and for reconstructing the manufacturing process of the analyzed artefacts.

  12. Nondestructive detection of surface flaws in materials by infrared thermography

    International Nuclear Information System (INIS)

    Ishii, Toshimitsu; Ooka, Norikazu; Eto, Motokuni; Hoshiya, Taiji; Okamoto, Yoshizo

    1999-01-01

    Infrared thermography is one of the useful remote sensing techniques applied to the nondestructive detection of surface flaws in materials. Radiation temperatures of the specimen surface and surrounding walls as well as the difference in them are crucial factors to detect surface flaws from thermal images, and it is essential that these factors be properly evaluated beforehand in order to detect the flaws by infrared thermography. In this study, the radiation temperature of nuclear graphite specimens heated uniformly was measured by infrared thermography to evaluate the radiation characteristics such as emissivity, radiosity coefficient and variation of radiation temperature. The influence of the temperature difference between the test specimen and its surroundings on the limit of detection of pinhole flaws was discussed on the basis of the thermal images of graphite specimen with surface flaws. It was found that the thermal image of a small flaw was clearly visible with increase in the temperature difference. (author)

  13. Infrared Thermography in Serotonin-Induced Itch Model in Rats

    DEFF Research Database (Denmark)

    Jasemian, Yousef; Gazerani, Parisa; Dagnæs-Hansen, Frederik

    2012-01-01

    The study validated the application of infrared thermography in a serotonin-induced itch model in rats since the only available method in animal models of itch is the count of scratching bouts. Twenty four adult Sprague-Dawley male rats were used in 3 experiments: 1) local vasomotor response...... with no scratching reflex was investigated. Serotonin elicited significant scratching and lowered the local temperature at the site of injection. A negative dose-temperature relationship of serotonin was found by thermography. Vasoregulation at the site of serotonin injection took place in the absence of scratching...

  14. Heat Flux Sensors for Infrared Thermography in Convective Heat Transfer

    Science.gov (United States)

    Carlomagno, Giovanni Maria; de Luca, Luigi; Cardone, Gennaro; Astarita, Tommaso

    2014-01-01

    This paper reviews the most dependable heat flux sensors, which can be used with InfraRed (IR) thermography to measure convective heat transfer coefficient distributions, and some of their applications performed by the authors' research group at the University of Naples Federico II. After recalling the basic principles that make IR thermography work, the various heat flux sensors to be used with it are presented and discussed, describing their capability to investigate complex thermo-fluid-dynamic flows. Several applications to streams, which range from natural convection to hypersonic flows, are also described. PMID:25386758

  15. Infrared thermography applied to monitoring of radioactive waste drums

    International Nuclear Information System (INIS)

    Kelmer, P.; Camarano, D.M.; Calado, F.; Phillip, B.; Viana, C.; Andrade, R.M.

    2013-01-01

    The use of thermography in the inspection of drums containing radioactive waste is being stimulated by the absence of physical contact. In Brazil the majority of radioactive wastes are compacted solids packed in metal drums stored temporarily for decades and requires special attention. These drums have only one qualitative indication of the radionuclides present. However, its structural condition is not followed systematically. The aim of this work is presents a methodology by applying thermography for monitoring the structural condition of drums containing radioactive waste in order to detect degraded regions of the drums. (author)

  16. Position of scintigraphy, radiography and thermography in arthropathic psoriasis

    International Nuclear Information System (INIS)

    Lips, H.; Schulze, P.; Loreck, D.

    1989-01-01

    In 28 patients suffering from an arthropathic psoriasis with a different duration of the articular symptoms besides clinical inspections roentgenologic and scintigraphic examinations of hands and feet as well as the liquid crystal thermography of the hands were accomplished. There was a conformity of clinical and scintigraphic findings in 64 per cent, of clinical and thermographic ones in 57 per cent of the cases. Scintigraphy as well as liquid crystal thermography are very suitable for early diagnosis of arthropathic psoriasis with articular symptoms not yet to be classifyable. X-ray examinations should be always taken into consideration not at least because of the differential diagnostic point of view. (author)

  17. Heat Flux Sensors for Infrared Thermography in Convective Heat Transfer

    Directory of Open Access Journals (Sweden)

    Giovanni Maria Carlomagno

    2014-11-01

    Full Text Available This paper reviews the most dependable heat flux sensors, which can be used with InfraRed (IR thermography to measure convective heat transfer coefficient distributions, and some of their applications performed by the authors’ research group at the University of Naples Federico II. After recalling the basic principles that make IR thermography work, the various heat flux sensors to be used with it are presented and discussed, describing their capability to investigate complex thermo-fluid-dynamic flows. Several applications to streams, which range from natural convection to hypersonic flows, are also described.

  18. Detection of defects of Kenaf/Epoxy by Thermography Analyses

    International Nuclear Information System (INIS)

    Suriani, M J; Ali, Aidi; Sapuan, S M; Khalina, A; Abdullah, S

    2012-01-01

    There are quite a few defects can occur due to manufacturing of the composites such as voids, resin-rich zones, pockets of undispersed cross-linker, misaligned fibres and regions where resin has poorly wetted the fibres. Such defect can reduce the mechanical properties as well mechanical performance of the structure and thus must be determine. In this study, the defect of Kenaf/epoxy reinforced composite materials has been determined by thermography analyses and mechanical properties testing of the composites have been done by tensile test. 95% of the thermography analyses have proved that the defects occur in the composite has reduced the mechanical properties of the specimens.

  19. Mythematics Solving the Twelve Labors of Hercules

    CERN Document Server

    Huber, Michael

    2009-01-01

    How might Hercules, the most famous of the Greek heroes, have used mathematics to complete his astonishing Twelve Labors? From conquering the Nemean Lion and cleaning out the Augean Stables, to capturing the Erymanthean Boar and entering the Underworld to defeat the three-headed dog Cerberus, Hercules and his legend are the inspiration for this book of fun and original math puzzles. While Hercules relied on superhuman strength to accomplish the Twelve Labors, Mythematics shows how math could have helped during his quest. How does Hercules defeat the Lernean Hydra and stop its heads from multip

  20. Breast Cancer Detection: Mammography and other methods in breast imaging, second edition

    International Nuclear Information System (INIS)

    Bassett, L.W.; Gold, R.H.

    1987-01-01

    The text addresses mammography and the advantages and limitations of other breast imaging methods presently available. The establishment of X-ray mammography as the safest and most accurate noninvasive method of early, nonpalpable breast cancer detection is addressed in the first section of the book. The second section emphasizes the signs of early cancer, the complete mammographic examination, and the team approach to diagnosis. The advantages and limitations of film-screen mammography, zero mammography, breast ultrasound, thermography, light scanning, magnetic resonance imaging, and ductography are highlighted as alternate methods of detection. The benefits of mammography, and its unmatched value in screeening for breast cancer, are presented in the final section

  1. Technologies of high-performance thermography systems

    Science.gov (United States)

    Breiter, R.; Cabanski, Wolfgang A.; Mauk, K. H.; Kock, R.; Rode, W.

    1997-08-01

    A family of 2 dimensional detection modules based on 256 by 256 and 486 by 640 platinum silicide (PtSi) focal planes, or 128 by 128 and 256 by 256 mercury cadmium telluride (MCT) focal planes for applications in either the 3 - 5 micrometer (MWIR) or 8 - 10 micrometer (LWIR) range was recently developed by AIM. A wide variety of applications is covered by the specific features unique for these two material systems. The PtSi units provide state of the art correctability with long term stable gain and offset coefficients. The MCT units provide extremely fast frame rates like 400 Hz with snapshot integration times as short as 250 microseconds and with a thermal resolution NETD less than 20 mK for e.g. the 128 by 128 LWIR module. The unique design idea general for all of these modules is the exclusively digital interface, using 14 bit analog to digital conversion to provide state of the art correctability, access to highly dynamic scenes without any loss of information and simplified exchangeability of the units. Device specific features like bias voltages etc. are identified during the final test and stored in a memory on the driving electronics. This concept allows an easy exchange of IDCAs of the same type without any need for tuning or e.g. the possibility to upgrade a PtSi based unit to an MCT module by just loading the suitable software. Miniaturized digital signal processor (DSP) based image correction units were developed for testing and operating the units with output data rates of up to 16 Mpixels/s. These boards provide the ability for freely programmable realtime functions like two point correction and various data manipulations in thermography applications.

  2. Damage detection in composites using nonlinear ultrasonically modulated thermography

    Science.gov (United States)

    Malfense Fierro, G.-P.; Dionysopoulos, D.; Meo, M.; Ciampa, F.

    2018-03-01

    This paper proposes a novel nonlinear ultrasonically stimulated thermography technique for a quick and reliable assessment of material damage in carbon fibre reinforced plastic (CFRP) composite materials. The proposed nondestructive evaluation (NDE) method requires narrow sweep ultrasonic excitation using contact piezoelectric transducers in order to identify dual excitation frequencies associated with the damage resonance. High-amplitude signals and higher harmonic generation are necessary conditions for an accurate identification of these two input frequencies. Dual periodic excitation using high- and low-frequency input signals was then performed in order to generate frictional heating at the crack location that was measured by an infrared (IR) camera. To validate this concept, an impact damaged CFRP composite panel was tested and the experimental results were compared with traditional flash thermography. A laser vibrometer was used to investigate the response of the material with dual frequency excitation. The proposed nonlinear ultrasonically modulated thermography successfully detected barely visible impact damage in CFRP composites. Hence, it can be considered as an alternative to traditional flash thermography and thermosonics by allowing repeatable detection of damage in composites.

  3. NASA MUST Paper: Infrared Thermography of Graphite/Epoxy

    Science.gov (United States)

    Comeaux, Kayla; Koshti, Ajay

    2010-01-01

    The focus of this project is to use Infrared Thermography, a non-destructive test, to detect detrimental cracks and voids beneath the surface of materials used in the space program. This project will consist of developing a simulation model of the Infrared Thermography inspection of the Graphite/Epoxy specimen. The simulation entails finding the correct physical properties for this specimen as well as programming the model for thick voids or flat bottom holes. After the simulation is completed, an Infrared Thermography inspection of the actual specimen will be made. Upon acquiring the experimental test data, an analysis of the data for the actual experiment will occur, which includes analyzing images, graphical analysis, and analyzing numerical data received from the infrared camera. The simulation will then be corrected for any discrepancies between it and the actual experiment. The optimized simulation material property inputs can then be used for new simulation for thin voids. The comparison of the two simulations, the simulation for the thick void and the simulation for the thin void, provides a correlation between the peak contrast ratio and peak time ratio. This correlation is used in the evaluation of flash thermography data during the evaluation of delaminations.

  4. An implementation of infrared thermography in maintenance plans within a world class manufacturing strategy

    Directory of Open Access Journals (Sweden)

    Todorović Petar M.

    2013-01-01

    Full Text Available The objective of the paper is to show the implementation of infrared thermography within World Class Manufacturing (WCM maintenance strategy. The results from infrared thermography inspections in a food processing and packaging solutions company were presented. Applicability of the infrared thermography, during a two-year period, caused a substantial reduction the potential breakdown in the pilot area. Upon feasibility confirmation, the proposed method was spread to other production equipment of the company.

  5. Improving visibility of rear surface cracks during inductive thermography of metal plates using Autoencoder

    Science.gov (United States)

    Xie, Jing; Xu, Changhang; Chen, Guoming; Huang, Weiping

    2018-06-01

    Inductive thermography is one kind of infrared thermography (IRT) technique, which is effective in detection of front surface cracks in metal plates. However, rear surface cracks are usually missed due to their weak indications during inductive thermography. Here we propose a novel approach (AET: AE Thermography) to improve the visibility of rear surface cracks during inductive thermography by employing the Autoencoder (AE) algorithm, which is an important block to construct deep learning architectures. We construct an integrated framework for processing the raw inspection data of inductive thermography using the AE algorithm. Through this framework, underlying features of rear surface cracks are efficiently extracted and new clearer images are constructed. Experiments of inductive thermography were conducted on steel specimens to verify the efficacy of the proposed approach. We visually compare the raw thermograms, the empirical orthogonal functions (EOFs) of the prominent component thermography (PCT) technique and the results of AET. We further quantitatively evaluated AET by calculating crack contrast and signal-to-noise ratio (SNR). The results demonstrate that the proposed AET approach can remarkably improve the visibility of rear surface cracks and then improve the capability of inductive thermography in detecting rear surface cracks in metal plates.

  6. Integration of infrared thermography into various maintenance methodologies

    Science.gov (United States)

    Morgan, William T.

    1993-04-01

    Maintenance methodologies are in developmental stages throughout the world as global competitiveness drives all industries to improve operational efficiencies. Rapid progress in technical advancements has added an additional strain on maintenance organizations to progressively change. Accompanying needs for advanced training and documentation is the demand for utilization of various analytical instruments and quantitative methods. Infrared thermography is one of the primary elements of engineered approaches to maintenance. Current maintenance methodologies can be divided into six categories; Routine ('Breakdown'), Preventive, Predictive, Proactive, Reliability-Based, and Total Productive (TPM) maintenance. Each of these methodologies have distinctive approaches to achieving improved operational efficiencies. Popular though is that infrared thermography is a Predictive maintenance tool. While this is true, it is also true that it can be effectively integrated into each of the maintenance methodologies for achieving desired results. The six maintenance strategies will be defined. Infrared applications integrated into each will be composed in tabular form.

  7. Infrared thermography application on predictive maintenance for exhaust fan motor

    International Nuclear Information System (INIS)

    I Wayan Widiana; Jakaria; Artadi Heru; Mulyono

    2013-01-01

    To determine the condition of the exhaust fan motor in terms of heat dissipation, predictive maintenance needs to be done. One way is to use infrared thermography. The method used is an infrared thermography with qualitative technique which the analysis focused on the distribution patterns of heat captured by the infrared camera. From measurement results expected to be obtained data of the heat distribution occurs in the motor exhaust fan so it can be given treatment or further improvements recommendations to avoid failure of the operation. Results of measurements on the motor exhaust fan 9 and the motor exhaust fan 10 indicates that there is excessive heat dissipation (over heating). The recommendation given is increasing the motor capacity of 11 kW to 18 kW with a consideration of the addition load on exhaust fan system and age of motor more than 22 years. (author)

  8. Investigation on a new inducer of pulsed eddy current thermography

    Directory of Open Access Journals (Sweden)

    Min He

    2016-09-01

    Full Text Available In this paper, a new inducer of pulsed eddy current thermography (PECT is presented. The use of the inducer can help avoid the problem of blocking the infrared (IR camera’s view in eddy current thermography technique. The inducer can also provide even heating of the test specimen. This paper is concerned with the temperature distribution law around the crack on a specimen when utilizing the new inducer. Firstly, relative mathematical models are provided. In the following section, eddy current distribution and temperature distribution around the crack are studied using the numerical simulation method. The best separation distance between the inducer and the specimen is also determined. Then, results of temperature distribution around the crack stimulated by the inducer are gained by experiments. Effect of current value on temperature rise is studied as well in the experiments. Based on temperature data, temperature features of the crack are discussed.

  9. Calibrated Pulse-Thermography Procedure for Inspecting HDPE

    Directory of Open Access Journals (Sweden)

    Mohammed A. Omar

    2008-01-01

    Full Text Available This manuscript discusses the application of a pulse-thermography modality to evaluate the integrity of a high-density polyethylene HDPE joint for delamination, in nonintrusive manner. The inspected HDPE structure is a twin-cup shape, molded through extrusion, and the inspection system comprises a high-intensity, short-duration radiation pulse to excite thermal emission; the text calibrates the experiment settings (pulse duration, and detector sampling rate to accommodate HDPE bulks thermal response. The acquired thermal scans are processed through new contrast computation named “self-referencing”, to investigate the joint tensile strength and further map its adhesion interface in real-time. The proposed system (hardware, software combination performance is assessed through an ultrasound C-scan validation and further benchmarked using a standard pulse phase thermography (PPT routine.

  10. Application of Infrared Thermography in Power Distribution System

    Directory of Open Access Journals (Sweden)

    Anwer Ali Sahito

    2014-07-01

    Full Text Available Electricity sector of Pakistan is facing daunting energy crisis. Generation deficit results in long duration of load shedding throughout the country. Old aged distribution system, lack of maintenance and equipment failure cause long unplanned outages and frequent supply interruptions. HESCO (Hyderabad Electric Supply Company is facing high technical losses, supply interruption and financial loss due to transformer damages. Infrared Thermography is non-contact, safe and fast measure for distribution system inspection. In this paper, thermographic inspection for different distribution system equipment is carried out to identify possible developed faults. It is observed that IR (Infrared thermography is effective measure for detecting developed faulty conditions at the initial stages to avoid unplanned outages

  11. Divertor IR thermography on Alcator C-Moda)

    Science.gov (United States)

    Terry, J. L.; LaBombard, B.; Brunner, D.; Payne, J.; Wurden, G. A.

    2010-10-01

    Alcator C-Mod is a particularly challenging environment for thermography. It presents issues that will similarly face ITER, including low-emissivity metal targets, low-Z surface films, and closed divertor geometry. In order to make measurements of the incident divertor heat flux using IR thermography, the C-Mod divertor has been modified and instrumented. A 6° toroidal sector has been given a 2° toroidal ramp in order to eliminate magnetic field-line shadowing by imperfectly aligned divertor tiles. This sector is viewed from above by a toroidally displaced IR camera and is instrumented with thermocouples and calorimeters. The camera provides time histories of surface temperatures that are used to compute incident heat-flux profiles. The camera sensitivity is calibrated in situ using the embedded thermocouples, thus correcting for changes and nonuniformities in surface emissivity due to surface coatings.

  12. Thermography in the detection and follow up of chondromalacia patellae.

    OpenAIRE

    Vujcić, M; Nedeljković, R

    1991-01-01

    Although diagnostic criteria for chondromalacia patellae exist, the disease is often accompanied by physical signs which are limited or non-diagnostic. Thermographic examination was performed in 157 patients with clinical diagnosis of chondromalacia patellae in 86 patients after surgical treatment for chondromalacia, and in 308 controls. Thermography can help the clinicians in establishing the diagnosis of chondromalacia patellae, but by itself is not sufficiently specific. The specificity of...

  13. Pulsed Thermography for Depth Profiling in Marble Sulfation

    Science.gov (United States)

    Bison, P.; Clarelli, F.; Vannozzi, A.

    2015-06-01

    Deterioration of stones is a complex problem and one of the main concern for people working in the field of conservation and restoration of cultural heritage. One important point in cultural heritage is to obtain information about the damage in a non-invasive way. By this paper, we propose a new non-invasive tool that permits evaluation of the thickness of (gypsum) grown (sulfation) on marble stones, using a mathematical model on data detected by pulsed infrared thermography.

  14. Thermography Control of Heat Insulation and Tightness of Buildings,

    Science.gov (United States)

    1980-11-01

    construction. The method is pedagogical . Results from thermography studies are suitable for use when giving experience feedback. (Excellent complement...visual inspection Instrument Various tools and measures. Principle The construction is opened, and the workmanship of insulation and tight- ness is...most IR cameras. At -196 C (77K) it is sensitive within the wavelength range 0 - 5.6 jam. The lower - 24 - FIGURE 3: Photography with IR camera, AGA

  15. Analysis of Heat Generation Mechanism in Ultrasound Infrared Thermography

    International Nuclear Information System (INIS)

    Choi, Man Yong; Lee, Seung Seok; Park, Jeong Hak; Kang, Ki Soo; Kim, Won Tae

    2009-01-01

    Heat generation mechanism of ultrasound infrared thermography is still not well understood, yet and there are two reliable assumptions of heat generation, friction and thermo-mechanical effect. This paper investigates the principal cause of heat generation at fatigue crack with experimental and numerical approach. Our results show most of heat generation is contributed by friction between crack interface and thermo-mechanical effect is a negligible quantity

  16. Extraction of Independent Structural Images for Principal Component Thermography

    Directory of Open Access Journals (Sweden)

    Dmitry Gavrilov

    2018-03-01

    Full Text Available Thermography is a powerful tool for non-destructive testing of a wide range of materials. Thermography has a number of approaches differing in both experiment setup and the way the collected data are processed. Among such approaches is the Principal Component Thermography (PCT method, which is based on the statistical processing of raw thermal images collected by thermal camera. The processed images (principal components or empirical orthogonal functions form an orthonormal basis, and often look like a superposition of all possible structural features found in the object under inspection—i.e., surface heating non-uniformity, internal defects and material structure. At the same time, from practical point of view it is desirable to have images representing independent structural features. The work presented in this paper proposes an approach for separation of independent image patterns (archetypes from a set of principal component images. The approach is demonstrated in the application of inspection of composite materials as well as the non-invasive analysis of works of art.

  17. Laser active thermography for non-destructive testing

    International Nuclear Information System (INIS)

    Semerok, A.; Grisolia, C.; Fomichev, S.V.; Thro, P.Y.

    2013-01-01

    Thermography methods have found their applications in different fields of human activity. The non-destructive feature of these methods along with the additional advantage by automated remote control and tests of nuclear installations without personnel attendance in the contaminated zone are of particular interest. Laser active pyrometry and laser lock-in thermography for in situ non-destructive characterization of micrometric layers on graphite substrates from European tokamaks were under extensive experimental and theoretical studies in CEA (France). The studies were aimed to obtain layer characterization with cross-checking the layer thermal contact coefficients determined by active laser pyrometry and lock-in thermography. The experimental installation comprised a Nd-YAG pulsed repetition rate laser (1 Hz - 10 kHz repetition rate frequency, homogeneous spot) and a home-made pyrometer system based on two pyrometers for the temperature measurements in 500 - 2600 K range. For both methods, the layer characterization was provided by the best fit of the experimental results and simulations. The layer thermal contact coefficients determined by both methods were quite comparable. Though there was no gain in the measurements accuracy, lock-in measurements have proved their advantage as being much more rapid. The obtained experimental and theoretical results are presented. Some practical applications and possible improvements of the methods are discussed. (authors)

  18. Sub-surface defect detection using transient thermography

    International Nuclear Information System (INIS)

    Mohd Zaki Umar; Huda Abdullah; Abdul Razak Hamzah; Wan Saffiey Wan Abdullah; Ibrahim Ahmad; Vavilov, Vladimir

    2009-04-01

    An experimental research had been carried out to study the potential of transient thermography in detecting sub-surface defect of non-metal material. In this research, eight pieces of bakelite material were used as samples. Each samples had a sub-surface defect in the circular shape with different diameters and depths. Experiment was conducted using one-sided Pulsed Thermal technique. Heating of samples were done using 30 k Watt adjustable quartz lamp while infra red (IR) images of samples were recorded using THV 550 IR camera. These IR images were then analysed with thermo fit TM Pro software to obtain the Maximum Absolute Differential Temperature Signal value, ΔT max and the time of its appearance, τ max (ΔT). Result showed that all defects were able to be detected even for the smallest and deepest defect (diameter = 5 mm and depth = 4 mm). However the highest value of Differential Temperature Signal (ΔT max ), were obtained at defect with the largest diameter, 20 mm and at the shallowest depth, 1 mm. As a conclusion, the sensitivity of the pulsed thermography technique to detect sub-surface defects of bakelite material is proportionately related with the size of defect diameter if the defect area at the same depth. On the contrary, the sensitivity of the pulsed thermography technique inversely related with the depth of defect if the defects have similar diameter size. (author)

  19. Laser active thermography for non-destructive testing

    Science.gov (United States)

    Semerok, A.; Grisolia, C.; Fomichev, S. V.; Thro, P.-Y.

    2013-11-01

    Thermography methods have found their applications in different fields of human activity. The non-destructive feature of these methods along with the additional advantage by automated remote control and tests of nuclear installations without personnel attendance in the contaminated zone are of particular interest. Laser active pyrometry and laser lock-in thermography for in situ non-destructive characterization of micrometric layers on graphite substrates from European tokamaks were under extensive experimental and theoretical studies in CEA (France). The studies were aimed to obtain layer characterization with cross-checking the layer thermal contact coefficients determined by active laser pyrometry and lock-in thermography. The experimental installation comprised a Nd-YAG pulsed repetition rate laser (1 Hz - 10 kHz repetition rate frequency, homogeneous spot) and a home-made pyrometer system based on two pyrometers for the temperature measurements in 500 - 2600 K range. For both methods, the layer characterization was provided by the best fit of the experimental results and simulations. The layer thermal contact coefficients determined by both methods were quite comparable. Though there was no gain in the measurements accuracy, lock-in measurements have proved their advantage as being much more rapid. The obtained experimental and theoretical results are presented. Some practical applications and possible improvements of the methods are discussed.

  20. [Diagnostic relevance of contact thermography in renal transplantation (author's transl)].

    Science.gov (United States)

    Kopsa, H

    1980-01-01

    102 renal transplant recipients were checked by contact thermography according to Tricoire for 2 1/2 years. Diagnostic value of this non invasive, quickly available and reproduceable method was investigated. The grafted kidney reveals on the thermographic screen its size, site, and vascularisation. The thermograhic pattern of a well functioning transplant shows warm areas in green, blue and violet colour. Onset of acute or chronic renal rejection leads to impaired heat conduction to the body surface either by oedema or by diminished blood flow. By photographic documentation in natural colour spotted or diffuse cold regions of brown, maroon and orange are seen. In the very early posttransplant period up to two months thermography is helpful in differential diagnosis for those recipients requiring initial haemodialysis treatment. Information is available between non functioning grafts with diminished renal blood supply and transplants with acute tubular necrosis. Impressive thermograms are found by rupture and subrupture of the kidney respectively. Superficial perirenal changes lead to topical temperature elevation as well. The high reliability of 92% correct diagnoses depends on exact application of the thermosensitive film and on determination of the basic individual skin temperature in reference to repeated examinations of the grafted area. Temperature measurement is influenced by subcutaneous abdominal fat distribution and muscle thickness as well as by deep position of the transplant or asymmetry of the lower abdominal region. In the wide field of diagnostic procedures necessary for transplant recipients with complications thermography by Tricoire is recommended.

  1. Optical and mechanical excitation thermography for impact response in basalt-carbon hybrid fiber-reinforced composite laminates

    OpenAIRE

    Zhang, Hai; Sfarra, Stefano; Sarasini, Fabrizio; Ibarra-Castanedo, Clemente; Perilli, Stefano; Fernandes, Henrique; Duan, Yuxia; Peeters, Jeroen; Avelidis, Nicholas P; Maldague, Xavier

    2017-01-01

    Abstract: In this paper, optical and mechanical excitation thermography were used to investigate basalt fiber reinforced polymer (BFRP), carbon fiber reinforced polymer (CFRP) and basalt-carbon fiber hybrid specimens subjected to impact loading. Interestingly, two different hybrid structures including sandwich-like and intercalated stacking sequence were used. Pulsed phase thermography (PPT), principal component thermography (PCT) and partial least squares thermography (PLST) were used to pro...

  2. KNOWLEDGE ATTITUDE AND PRACTICE ABOUT BREAST ...

    African Journals Online (AJOL)

    Three hundred and twelve (81.0%) respondents knew correctly that breast lump is usually the first symptom of presentation of breast cancer. One hundred and forty ... Three hundred and seventy two (96.6%) respondents know that mastectomy is done as part of the management of breast cancer, but only forty nine (12.7%)

  3. Comparison of different non-invasive screening methods in the diagnosis of stage T/sub 1/ breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Bartl, W; Euller, A; Pfersmann, C; Bernaschek, G; Breitenecker, G

    1984-10-01

    52 women with stage T/sub 1/ breast cancer were investigated by thermography, mammography and ultrasound and the results compared with the patients age, histological tumour type and the degree of malignancy. The best results were achieved by mammography (sensitivity: 85%). In tumours with a large amount of connective tissue (scirrhous or invasive lobular cancer) sensitivity rose to 94%, while in tumours with little connective tissue (solid, medullary, adenomatous and papillary) sensitivity decreased to 69%. The respective values for thermographic sensitivity were 44% and 77% and for ultrasound sensitivity in palpable tumours 85% and 65%, respectively. On mammography 3 carcinomas were not recognized, all three in younger patients; on thermography also three false negative results were obtained, but all in older patients. The sensitivity of thermography increases in parallel with increasing degree of tumour malignancy. Whilst ultrasound is a valuable aid for differential diagnosis in palpable tumours only, screening results can evidently be improved by a combination of thermography and mammography.

  4. A comparison of different non-invasive screening methods in the diagnosis of stage T1 breast cancer

    International Nuclear Information System (INIS)

    Bartl, W.; Euller, A.; Pfersmann, C.; Bernaschek, G.; Breitenecker, G.

    1984-01-01

    52 women with stage T 1 breast cancer were investigated by thermography, mammography and ultrasound and the results compared with the patients age, histological tumour type and the degree of malignancy. The best results were achieved by mammography (sensitivity: 85%). In tumours with a large amount of connective tissue (scirrhous or invasive lobular cancer) sensitivity rose to 94%, whilst in tumours with little connective tissue (solid, medullary, adenomatous and papillary) sensitivity decreased to 69%. The respective values for thermographic sensitivity were 44% and 77% and for ultrasound sensitivity in palpable tumours 85% and 65%, respectively. On mammography 3 carcinomas were not recognized, all three in younger patients; on thermography also three false negative results were obtained, but all in older patients. The sensitivity of thermography increases in parallel with increasing degree of tumour malignancy. Whilst ultrasound is a valuable aid for differential diagnosis in palpable tumours only, screening results can evidently be improved by a combination of thermography and mammography. (Author)

  5. [Twelve years of liver transplantation in Lausanne].

    Science.gov (United States)

    Mosimann, F; Bettschart, V; Gardaz, J P; Fontolliet, C; Tissot, J D; Meuwly, J Y; Chioléro, R; Gillet, M

    2001-02-01

    From 1988 to June 2000 138 transplantations were performed in 129 adult patients. Actuarial patient and graft survivals have been 80.7% and 75.4% at one year and 67.8% and 63.5% at 10 years. This compares favourably with the statistics of the European Liver Transplant Registry that collected data from more than 30,000 grafts. Over the twelve years of activity, the indications have become more liberal and the techniques have been simplified. The waiting list has therefore grown and some patients are now unfortunately dying before a graft can be found because the number of brain dead donors remains stable. In order to palliate this shortage, older donors are now being accepted even with co-morbidities and/or moderate alterations of the liver function tests. The use of live donors and the split of the best cadaveric grafts for two recipients will also reduce the gap between the demand and the offer.

  6. Twelve Girls' Band' A Modern Miracle of Traditional Music

    Institute of Scientific and Technical Information of China (English)

    YaoZhanxiong

    2004-01-01

    Twelve antique traditional instruments. Twelve spirited, pretty girls. "Twelve Girls' Band" is a traditional instrument orchestra playing well-known folk music in the form of pop. Besides age-old traditional instruments peculiar to China, such as zheng (ancient 21 to 25-stringed plucked instrument), qin (seven-stringed plucked instrument) and erhu (two-stringed Chinese fiddle),

  7. Study on the Micro Crack Detection in Joints by Using Ultrasound Infrared Thermography

    International Nuclear Information System (INIS)

    Park, Hee Sang; Choi, Man Yong; Park, Jeong Hak; Lee, Seung Seok; Huh, Yong Hak; Lee, Bo Young; Jae Seong

    2012-01-01

    This study detected SCC defects of dissimilar metal welded(STS304 and SA106 Gr. b) pipes using the ultrasonic infrared thermography method and the lock-in image treatment method among infrared thermography method. The infrared excitement equipment has 250 Watt of output and 20 kHz of frequency. By using the ultrasound infrared thermography method, the internal defects of dissimilar metal weld joints of pipes used at nuclear power plants could get detected. By an actual PT test, it was observed that the cracks inside the pipe existed not as a single crack but rather as a multiple cracks within a certain area and generated a hot spot image of a broad area on the thermography image. In addition, UT technology could not easily defects detected by the width of 10 μm fine hair cracks. but, ultrasound infrared thermography technique was defect detected

  8. Antifouling activity of twelve demosponges from Brazil

    Directory of Open Access Journals (Sweden)

    SM. Ribeiro

    Full Text Available Benthic marine organisms are constantly exposed to fouling, which is harmful to most host species. Thus, the production of secondary metabolites containing antifouling properties is an important ecological advantage for sessile organisms and may also provide leading compounds for the development of antifouling paints. High antifouling potential of sponges has been demonstrated in the Indian and Pacific oceans and in the Caribbean and Mediterranean seas. Brazilian sponges remain understudied concerning antifouling activities. Only two scientific articles reported this activity in sponges of Brazil. The objective of this study was to test crude extracts of twelve species of sponges from Brazil against the attachment of the mussel Perna perna through laboratorial assays, and highlight promising species for future studies. The species Petromica citrina, Amphimedon viridis, Desmapsamma anchorata, Chondrosia sp., Polymastia janeirensis, Tedania ignis, Aplysina fulva, Mycale angulosa, Hymeniacidon heliophila, Dysidea etheria, Tethya rubra, and Tethya maza were frozen and freeze-dried before extraction with acetone or dichloromethane. The crude extract of four species significantly inhibited the attachment of byssus: Tethya rubra (p = 0.0009, Tethya maza (p = 0.0039, Petromica citrina (p = 0.0277, and Hymeniacidon heliophila (p = 0.00003. These species, specially, should be the target of future studies to detail the substances involved in the ability antifouling well as to define its amplitude of action.

  9. Energy and greenhouse effect. Twelve short notes

    International Nuclear Information System (INIS)

    Prevot, Henri

    2013-12-01

    The author proposes twelve brief notes aimed at discussing the reduction of fossil energy consumption in order to reduce CO 2 emissions and to improve the French energy supply security, without any useless expense. These notes address the reason for energy savings, the cost and price of a CO 2 ton, the issue of thermal regulation for buildings (it's not in compliance with the law, and results in higher expenses and increased CO 2 emissions), the introduction of a carbon tax to incite investments for energy saving, the status and health of the CO 2 European market, the support of actions aimed at reducing fossil energy consumption, the fact that bio-heat is ten times more efficient than bio-fuel and that therefore car holders should finance bio-heat, the development of hybrid uses of energy to avoid the difficulty of energy storage, the reduction of CO 2 emissions at low cost (by consuming as much renewable energy as nuclear energy but without wind or photovoltaic energy), the cost of less CO 2 , less fossil energy and less nuclear, and the interest of France to act on its own to reduce CO 2 emissions. The author proposes a brief synthesis of these notes and some proposals regarding thermal regulation for buildings, taxes, the European CO 2 market, the forest biomass, electricity production, and the European and word dimensions of these issues

  10. Using infrared thermography for understanding and quantifying soil surface processes

    Science.gov (United States)

    de Lima, João L. M. P.

    2017-04-01

    At present, our understanding of the soil hydrologic response is restricted by measurement limitations. In the literature, there have been repeatedly calls for interdisciplinary approaches to expand our knowledge in this field and eventually overcome the limitations that are inherent to conventional measuring techniques used, for example, for tracing water at the basin, hillslope and even field or plot scales. Infrared thermography is a versatile, accurate and fast technique of monitoring surface temperature and has been used in a variety of fields, such as military surveillance, medical diagnosis, industrial processes optimisation, building inspections and agriculture. However, many applications are still to be fully explored. In surface hydrology, it has been successfully employed as a high spatial and temporal resolution non-invasive and non-destructive imaging tool to e.g. access groundwater discharges into waterbodies or quantify thermal heterogeneities of streams. It is believed that thermal infrared imagery can grasp the spatial and temporal variability of many processes at the soil surface. Thermography interprets the heat signals and can provide an attractive view for identifying both areas where water is flowing or has infiltrated more, or accumulated temporarily in depressions or macropores. Therefore, we hope to demonstrate the potential for thermal infrared imagery to indirectly make a quantitative estimation of several hydrologic processes. Applications include: e.g. mapping infiltration, microrelief and macropores; estimating flow velocities; defining sampling strategies; identifying water sources, accumulation of waters or even connectivity. Protocols for the assessment of several hydrologic processes with the help of IR thermography will be briefly explained, presenting some examples from laboratory soil flumes and field.

  11. Simultaneous neutron radiography and infrared thermography measurement of boiling processes

    International Nuclear Information System (INIS)

    Murphy, J.H.; Glickstein, S.S.

    1997-01-01

    Boiling of water at 1 to 15 bar flowing upward within a narrow duct and a round test section was observed using both neutron radiography and infrared (IR) thermography. The IR readings of the test section outer wall temperatures show the effects of both fluid temperature and wall heat transfer coefficient variations, producing a difference between liquid and two phase regions. The IR images, in fact, appear very similar to the neutron images; both show clear indications of spatial and temporal variations in the internal fluid conditions during the boiling process

  12. Pulsed infrared thermography for assessment of ultrasonic welds

    Science.gov (United States)

    McGovern, Megan E.; Rinker, Teresa J.; Sekol, Ryan C.

    2018-03-01

    Battery packs are a critical component in electric vehicles. During pack assembly, the battery cell tab and busbar are ultrasonically welded. The properties of the welds ultimately affect battery pack durability. Quality inspection of these welds is important to ensure durable battery packs. Pack failure is detrimental economically and could also pose a safety hazard, such as thermal runaway. Ultrasonic welds are commonly checked by measuring electrical resistance or auditing using destructive mechanical testing. Resistance measurements are quick, but sensitive to set-up changes. Destructive testing cannot represent the entire weld set. It is possible for a weak weld to satisfy the electrical requirement check, because only sufficient contact between the tabs and busbar is required to yield a low resistance measurement. Laboratory techniques are often not suitable for inline inspection, as they may be time-consuming, use couplant, or are only suitable for coupons. The complex surface geometry also poses difficulties for conventional nondestructive techniques. A method for inspection of ultrasonic welds is proposed using pulsed infrared thermography to identify discrepant welds in a manufacturing environment. Thermal measurements of welds were compared to electrical and mechanical measurements. The heat source distribution was calculated to obtain thermal images with high temporal and spatial resolution. All discrepant welds were readily identifiable using two thermographic techniques: pixel counting and the gradient image. A positive relationship between pixel count and mechanical strength was observed. The results demonstrate the potential of pulsed thermography for inline inspection, which can complement, or even replace, conventional electrical resistance measurements.

  13. Robust remote monitoring of breathing function by using infrared thermography.

    Science.gov (United States)

    Pereira, Carina B; Yu, Xinchi; Blazek, Vladimir; Leonhardt, Steffen

    2015-01-01

    An abnormal breathing rate (BR) is one of the strongest markers of physiological distress. Moreover, it plays an important role in early detection of sudden infant death syndrome, as well as in the diagnosis of respiratory disorders. However, the current measuring modalities can cause discomfort to the patient, since attachment to the patient's body is required. This paper proposes a new approach based on infrared thermography to remotely monitor BR. This method allows to (1) detect automatically the nose, (2) track the associate region of interest (ROI), and (3) extract BR. To evaluate the performance of this method, thermal recording of 5 healthy subjects were acquired. Results were compared with BR obtained by capnography. The introduced approach demonstrated an excellent performance. ROIs were precisely segmented and tracked. Furthermore, a Bland-Altman diagram showed a good agreement between estimated BR and gold standard. The mean correlation and mean absolute BR error are 0.92 ± 0.07 and 0.53 bpm, respectively. In summary, infrared thermography seems to be a great, clinically relevant alternative to attached sensors, due to its outstanding characteristics and performance.

  14. Thermal comfort of seats as visualized by infrared thermography.

    Science.gov (United States)

    Sales, Rosemary Bom Conselho; Pereira, Romeu Rodrigues; Aguilar, Maria Teresa Paulino; Cardoso, Antônio Valadão

    2017-07-01

    Published studies that deal with the question of how the temperature of chair seats influences human activities are few, but the studies considering such a factor, a function of the type of material, could contribute to improvements in the design of chairs. This study evaluates seat temperatures of 8 types of chairs made of different materials. The parts of the furniture that people come into contact with, and the thermal response of the material to heating and cooling have been evaluated. Infrared thermography was used for this, as it is a non-contact technique that does not present any type of risk in the measurement of temperatures. Seats made of synthetic leather (leatherette), wood and polyester fabric were found to have the highest temperatures, and the plywood seat showed the lowest. The study has also revealed that thermography can contribute to studies of thermal comfort of chair seats in addition to determining the most suitable material. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Medical applications of model-based dynamic thermography

    Science.gov (United States)

    Nowakowski, Antoni; Kaczmarek, Mariusz; Ruminski, Jacek; Hryciuk, Marcin; Renkielska, Alicja; Grudzinski, Jacek; Siebert, Janusz; Jagielak, Dariusz; Rogowski, Jan; Roszak, Krzysztof; Stojek, Wojciech

    2001-03-01

    The proposal to use active thermography in medical diagnostics is promising in some applications concerning investigation of directly accessible parts of the human body. The combination of dynamic thermograms with thermal models of investigated structures gives attractive possibility to make internal structure reconstruction basing on different thermal properties of biological tissues. Measurements of temperature distribution synchronized with external light excitation allow registration of dynamic changes of local temperature dependent on heat exchange conditions. Preliminary results of active thermography applications in medicine are discussed. For skin and under- skin tissues an equivalent thermal model may be determined. For the assumed model its effective parameters may be reconstructed basing on the results of transient thermal processes. For known thermal diffusivity and conductivity of specific tissues the local thickness of a two or three layer structure may be calculated. Results of some medical cases as well as reference data of in vivo study on animals are presented. The method was also applied to evaluate the state of the human heart during the open chest cardio-surgical interventions. Reference studies of evoked heart infarct in pigs are referred, too. We see the proposed new in medical applications technique as a promising diagnostic tool. It is a fully non-invasive, clean, handy, fast and affordable method giving not only qualitative view of investigated surfaces but also an objective quantitative measurement result, accurate enough for many applications including fast screening of affected tissues.

  16. Nde of Frp Wrapped Columns Using Infrared Thermography

    Science.gov (United States)

    Halabe, Udaya B.; Dutta, Shasanka Shekhar; GangaRao, Hota V. S.

    2008-02-01

    This paper investigates the feasibility of using Infrared Thermography (IRT) for detecting debonds in Fiber Reinforced Polymer (FRP) wrapped columns. Laboratory tests were conducted on FRP wrapped concrete cylinders of size 6″×12″ (152.4 mm×304.8 mm) in which air-filled and water-filled debonds of various sizes were placed underneath the FRP wraps. Air-filled debonds were made by cutting plastic sheets into the desired sizes whereas water-filled debonds were made by filling water in custom made polyethylene pouches. Both carbon and glass fiber reinforced wraps were considered in this study. Infrared tests were conducted using a fully radiometric digital infrared camera which was successful in detecting air-filled as well as water-filled subsurface debonds. In addition to the laboratory testing, two field trips were made to Moorefield, West Virginia for detecting subsurface debonds in FRP wrapped timber piles of a railroad bridge using infrared testing. The results revealed that infrared thermography can be used as an effective nondestructive evaluation tool for detecting subsurface debonds in structural components wrapped with carbon or glass reinforced composite fabrics.

  17. Eddy Current Thermography: System Development and Its Application in NDT

    International Nuclear Information System (INIS)

    Nurliyana Shamimie Rusli; Ilham Mukriz Zainal Abidin; Sidek, H.A.A.

    2015-01-01

    Eddy Current Thermography (ECT) is an integrative technique which combines eddy current and thermographic NDT in order to provide an efficient method for defect detection. The technique is applicable to electrically conductive material and has the ability to detect surface and subsurface defect. ECT is a non-contact technique; has the ability to provide instantaneous response and high scanning speed that makes it reliable for defect detection and assessment. The technique combines electromagnetic excitation of the work-piece via a coil carrying current, heating of the material by induction and inspection by transient infrared thermography. In this paper, the development of ECT system is detailed, including coil design for global and local heating of samples, and optimisation of excitation parameters (frequency, power, heating duration etc). Results from 3D FEM simulation and experimental investigations are also presented to provide the overview of underlying phenomena and application of ECT. The work demonstrates the effectiveness of the developed ECT system and technique in defect detection and assessment. (author)

  18. Lock-in thermography using a cellphone attachment infrared camera

    Science.gov (United States)

    Razani, Marjan; Parkhimchyk, Artur; Tabatabaei, Nima

    2018-03-01

    Lock-in thermography (LIT) is a thermal-wave-based, non-destructive testing, technique which has been widely utilized in research settings for characterization and evaluation of biological and industrial materials. However, despite promising research outcomes, the wide spread adaptation of LIT in industry, and its commercialization, is hindered by the high cost of the infrared cameras used in the LIT setups. In this paper, we report on the feasibility of using inexpensive cellphone attachment infrared cameras for performing LIT. While the cost of such cameras is over two orders of magnitude less than their research-grade counterparts, our experimental results on block sample with subsurface defects and tooth with early dental caries suggest that acceptable performance can be achieved through careful instrumentation and implementation of proper data acquisition and image processing steps. We anticipate this study to pave the way for development of low-cost thermography systems and their commercialization as inexpensive tools for non-destructive testing of industrial samples as well as affordable clinical devices for diagnostic imaging of biological tissues.

  19. A Classification Method for Seed Viability Assessment with Infrared Thermography

    Directory of Open Access Journals (Sweden)

    Sen Men

    2017-04-01

    Full Text Available This paper presents a viability assessment method for Pisum sativum L. seeds based on the infrared thermography technique. In this work, different artificial treatments were conducted to prepare seeds samples with different viability. Thermal images and visible images were recorded every five minutes during the standard five day germination test. After the test, the root length of each sample was measured, which can be used as the viability index of that seed. Each individual seed area in the visible images was segmented with an edge detection method, and the average temperature of the corresponding area in the infrared images was calculated as the representative temperature for this seed at that time. The temperature curve of each seed during germination was plotted. Thirteen characteristic parameters extracted from the temperature curve were analyzed to show the difference of the temperature fluctuations between the seeds samples with different viability. With above parameters, support vector machine (SVM was used to classify the seed samples into three categories: viable, aged and dead according to the root length, the classification accuracy rate was 95%. On this basis, with the temperature data of only the first three hours during the germination, another SVM model was proposed to classify the seed samples, and the accuracy rate was about 91.67%. From these experimental results, it can be seen that infrared thermography can be applied for the prediction of seed viability, based on the SVM algorithm.

  20. Lock-in thermography using a cellphone attachment infrared camera

    Directory of Open Access Journals (Sweden)

    Marjan Razani

    2018-03-01

    Full Text Available Lock-in thermography (LIT is a thermal-wave-based, non-destructive testing, technique which has been widely utilized in research settings for characterization and evaluation of biological and industrial materials. However, despite promising research outcomes, the wide spread adaptation of LIT in industry, and its commercialization, is hindered by the high cost of the infrared cameras used in the LIT setups. In this paper, we report on the feasibility of using inexpensive cellphone attachment infrared cameras for performing LIT. While the cost of such cameras is over two orders of magnitude less than their research-grade counterparts, our experimental results on block sample with subsurface defects and tooth with early dental caries suggest that acceptable performance can be achieved through careful instrumentation and implementation of proper data acquisition and image processing steps. We anticipate this study to pave the way for development of low-cost thermography systems and their commercialization as inexpensive tools for non-destructive testing of industrial samples as well as affordable clinical devices for diagnostic imaging of biological tissues.

  1. Characteristics on Temperature Evolution in the Metallic Specimen by Ultrasound-Excited Thermography

    Energy Technology Data Exchange (ETDEWEB)

    Choi, M. Y.; Park, J. H. [Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of); Kang, K. S. [Hyundai Steel Co., Dangjin (Korea, Republic of); Kim, W. T. [Kongju National University, Gongju (Korea, Republic of)

    2010-06-15

    In ultrasound-excited thermography, the injected ultrasound to an object is transformed to heat and the appearance of defects can be visualized by thermography camera. The advantage of this technology is selectively sensitive to thermally active defects. Despite the apparent simplicity of the scheme, there are a number of experimental considerations that can complicate the implementation of ultrasound excitation thermography inspection. Factors including acoustic horn location, horn-crack proximity, horn-sample coupling, and effective detection range all significantly affect the detect ability of this technology. As conclusions, the influence of coupling pressures between ultrasound exciter and specimen was analyzed, which was dominant factor in frictional heating model

  2. Online advertising by three commercial breast imaging services: message takeout and effectiveness.

    Science.gov (United States)

    Johnson, Rebecca; Jalleh, Geoffrey; Pratt, Iain S; Donovan, Robert J; Lin, Chad; Saunders, Christobel; Slevin, Terry

    2013-10-01

    Mammography is widely acknowledged to be the most cost-effective technique for population screening for breast cancer. Recently in Australia, imaging modalities other than mammography, including thermography, electrical impedance, and computerised breast imaging, have been increasingly promoted as alternative methods of breast cancer screening. This study assessed the impact of three commercial breast imaging companies' promotional material upon consumers' beliefs about the effectiveness of the companies' technology in detecting breast cancer, and consumers' intentions to seek more information or consider having their breasts imaged by these modalities. Results showed 90% of respondents agreed that the companies' promotional material promoted the message that the advertised breast imaging method was effective in detecting breast cancer, and 80% agreed that the material promoted the message that the imaging method was equally or more effective than a mammogram. These findings have implications for women's preference for and uptake of alternative breast imaging services over mammography. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Application of lock-in thermography non destructive technique to CFC armoured plasma facing components

    International Nuclear Information System (INIS)

    Escourbiac, F.; Constans, S.; Courtois, X.; Durocher, A.

    2007-01-01

    A non destructive testing technique - so called modulated photothermal thermography or lock-in thermography - has been set-up for plasma facing components examination. Reliable measurements of phase contrast were obtained on 8 mm carbon fiber composite (CFC) armoured W7-X divertor component with calibrated flaws. A 3D finite element analysis allowed the correlation of the measured phase contrast and showed that a 4 mm strip flaw can be detected at the CFC/copper interface

  4. The Use of Infrared Thermography as a Novel Approach for Real-Time Validation of PCR Thermocyclers

    DEFF Research Database (Denmark)

    Grønlund, Hugo Ahlm; Löfström, Charlotta; Helleskov, Jens Bue

    2010-01-01

    Validation of PCR thermocycler performance is crucial to obtain reliable results. In this study, infrared (IR) thermography was evaluated as a novel validation tool. After stabilisation, no significant difference in the temperatures recorded using thermography and a reference blockbased system wa...... was found. By employing IR thermography, information about the length of the time until temperature stabilisation in the sample could be obtained. This study shows the potential of using IR thermography for validation of thermocyclers.......Validation of PCR thermocycler performance is crucial to obtain reliable results. In this study, infrared (IR) thermography was evaluated as a novel validation tool. After stabilisation, no significant difference in the temperatures recorded using thermography and a reference blockbased system...

  5. The mental and subjective skin: Emotion, empathy, feelings and thermography.

    Science.gov (United States)

    Salazar-López, E; Domínguez, E; Juárez Ramos, V; de la Fuente, J; Meins, A; Iborra, O; Gálvez, G; Rodríguez-Artacho, M A; Gómez-Milán, E

    2015-07-01

    We applied thermography to investigate the cognitive neuropsychology of emotions, using it as a somatic marker of subjective experience during emotional tasks. We obtained results that showed significant correlations between changes in facial temperature and mental set. The main result was the change in the temperature of the nose, which tended to decrease with negative valence stimuli but to increase with positive emotions and arousal patterns. However, temperature change was identified not only in the nose, but also in the forehead, the oro-facial area, the cheeks and in the face taken as a whole. Nevertheless, thermic facial changes, mostly nasal temperature changes, correlated positively with participants' empathy scores and their performance. We found that temperature changes in the face may reveal maps of bodily sensations associated with different emotions and feelings like love. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Year-Round Use Of Thermography In House Doctoring

    Science.gov (United States)

    Gadsby, Kenneth J.; Harrje, David T.; Dutt, Gautam S.

    1983-03-01

    There have been many presentations of thermographic residential building analyses at the past ThermosInse conferences. A number of these papers have dealt with evaluation of insulation voids and more recently a few have described air leakage detection 2,3 during the colder winter months. This paper will focus on the thermographic application in the House Doctor instrumented energy analysis approach as developed by Princeton University. The central theme will be the application to a year-round research or commercial activity. Some of the conditions that could create thermographic problems, as well as techniques that may be used to lessen these difficulties, thereby extending the thermographic "season" is discussed. Our experiences in summer thermography with and without the use of a building pressurization system is also covered.

  7. Real time capable infrared thermography for ASDEX Upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Sieglin, B., E-mail: Bernhard.Sieglin@ipp.mpg.de; Faitsch, M.; Herrmann, A.; Brucker, B.; Eich, T.; Kammerloher, L.; Martinov, S. [Max-Planck Institute for Plasma Physics, Boltzmannstr. 2, D-85748 Garching (Germany)

    2015-11-15

    Infrared (IR) thermography is widely used in fusion research to study power exhaust and incident heat load onto the plasma facing components. Due to the short pulse duration of today’s fusion experiments, IR systems have mostly been designed for off-line data analysis. For future long pulse devices (e.g., Wendelstein 7-X, ITER), a real time evaluation of the target temperature and heat flux is mandatory. This paper shows the development of a real time capable IR system for ASDEX Upgrade. A compact IR camera has been designed incorporating the necessary magnetic and electric shielding for the detector, cooler assembly. The camera communication is based on the Camera Link industry standard. The data acquisition hardware is based on National Instruments hardware, consisting of a PXIe chassis inside and a fibre optical connected industry computer outside the torus hall. Image processing and data evaluation are performed using real time LabVIEW.

  8. Thermal behavior variations in coating thickness using pulse phase thermography

    Energy Technology Data Exchange (ETDEWEB)

    Ranjit, Shrestha; Chung, Yoonjae; Kim, Won Tae [Kongju National University, Cheonan (Korea, Republic of)

    2016-08-15

    This paper presents a study on the use of pulsed phase thermography in the measurement of thermal barrier coating thickness with a numerical simulation. A multilayer heat transfer model was used to analyze the surface temperature response acquired from one-sided pulsed thermal imaging. The test sample comprised four layers: the metal substrate, bond coat, thermally grown oxide and the top coat. The finite element software, ANSYS, was used to model and predict the temperature distribution in the test sample under an imposed heat flux on the exterior of the TBC. The phase image was computed with the use of the software MATLAB and Thermofit Pro using a Fourier transform. The relationship between the coating thickness and the corresponding phase angle was then established with the coating thickness being expressed as a function of the phase angle. The method is successfully applied to measure the coating thickness that varied from 0.25 mm to 1.5 mm.

  9. Prognostic value of infrared thermography in an emergency department

    DEFF Research Database (Denmark)

    Holm, Jesper K; Kellett, John G; Jensen, Nadia H

    2018-01-01

    OBJECTIVE: In this study, we aimed to investigate the prognostic potential of infrared thermography in a population of medical patients admitted to the emergency department. Central-to-peripheral temperature gradients were analyzed for association with 30-day mortality. METHODS: This prospective...... as a marker for central temperature and the three others as markers for peripheral temperatures, resulting in three gradients per patient. Thirty-day follow-up was performed and 30-day mortality was reported. RESULTS: One hundred and ninety-eight patients were included and the number of events was nine...... observational study included 198 medical patients admitted to the Emergency Department, at Odense University Hospital. A standardized thermal picture was taken and temperatures of the inner canthus, the earlobe, the nose tip, and the tip of the third finger were reported. The inner canthus was chosen...

  10. Recent Advances in Active Infrared Thermography for Non-Destructive Testing of Aerospace Components.

    Science.gov (United States)

    Ciampa, Francesco; Mahmoodi, Pooya; Pinto, Fulvio; Meo, Michele

    2018-02-16

    Active infrared thermography is a fast and accurate non-destructive evaluation technique that is of particular relevance to the aerospace industry for the inspection of aircraft and helicopters' primary and secondary structures, aero-engine parts, spacecraft components and its subsystems. This review provides an exhaustive summary of most recent active thermographic methods used for aerospace applications according to their physical principle and thermal excitation sources. Besides traditional optically stimulated thermography, which uses external optical radiation such as flashes, heaters and laser systems, novel hybrid thermographic techniques are also investigated. These include ultrasonic stimulated thermography, which uses ultrasonic waves and the local damage resonance effect to enhance the reliability and sensitivity to micro-cracks, eddy current stimulated thermography, which uses cost-effective eddy current excitation to generate induction heating, and microwave thermography, which uses electromagnetic radiation at the microwave frequency bands to provide rapid detection of cracks and delamination. All these techniques are here analysed and numerous examples are provided for different damage scenarios and aerospace components in order to identify the strength and limitations of each thermographic technique. Moreover, alternative strategies to current external thermal excitation sources, here named as material-based thermography methods, are examined in this paper. These novel thermographic techniques rely on thermoresistive internal heating and offer a fast, low power, accurate and reliable assessment of damage in aerospace composites.

  11. Recent Advances in Active Infrared Thermography for Non-Destructive Testing of Aerospace Components

    Directory of Open Access Journals (Sweden)

    Francesco Ciampa

    2018-02-01

    Full Text Available Active infrared thermography is a fast and accurate non-destructive evaluation technique that is of particular relevance to the aerospace industry for the inspection of aircraft and helicopters’ primary and secondary structures, aero-engine parts, spacecraft components and its subsystems. This review provides an exhaustive summary of most recent active thermographic methods used for aerospace applications according to their physical principle and thermal excitation sources. Besides traditional optically stimulated thermography, which uses external optical radiation such as flashes, heaters and laser systems, novel hybrid thermographic techniques are also investigated. These include ultrasonic stimulated thermography, which uses ultrasonic waves and the local damage resonance effect to enhance the reliability and sensitivity to micro-cracks, eddy current stimulated thermography, which uses cost-effective eddy current excitation to generate induction heating, and microwave thermography, which uses electromagnetic radiation at the microwave frequency bands to provide rapid detection of cracks and delamination. All these techniques are here analysed and numerous examples are provided for different damage scenarios and aerospace components in order to identify the strength and limitations of each thermographic technique. Moreover, alternative strategies to current external thermal excitation sources, here named as material-based thermography methods, are examined in this paper. These novel thermographic techniques rely on thermoresistive internal heating and offer a fast, low power, accurate and reliable assessment of damage in aerospace composites.

  12. The hybrid thermography approach applied to architectural structures

    Science.gov (United States)

    Sfarra, S.; Ambrosini, D.; Paoletti, D.; Nardi, I.; Pasqualoni, G.

    2017-07-01

    This work contains an overview of infrared thermography (IRT) method and its applications relating to the investigation of architectural structures. In this method, the passive approach is usually used in civil engineering, since it provides a panoramic view of the thermal anomalies to be interpreted also thanks to the use of photographs focused on the region of interest (ROI). The active approach, is more suitable for laboratory or indoor inspections, as well as for objects having a small size. The external stress to be applied is thermal, coming from non-natural apparatus such as lamps or hot / cold air jets. In addition, the latter permits to obtain quantitative information related to defects not detectable to the naked eyes. Very recently, the hybrid thermography (HIRT) approach has been introduced to the attention of the scientific panorama. It can be applied when the radiation coming from the sun, directly arrives (i.e., possibly without the shadow cast effect) on a surface exposed to the air. A large number of thermograms must be collected and a post-processing analysis is subsequently applied via advanced algorithms. Therefore, an appraisal of the defect depth can be obtained passing through the calculation of the combined thermal diffusivity of the materials above the defect. The approach is validated herein by working, in a first stage, on a mosaic sample having known defects while, in a second stage, on a Church built in L'Aquila (Italy) and covered with a particular masonry structure called apparecchio aquilano. The results obtained appear promising.

  13. Liquid crystal foil for the detection of breast cancer

    Science.gov (United States)

    Biernat, Michał; Trzyna, Marcin; Byszek, Agnieszka; Jaremek, Henryk

    2016-09-01

    Breast cancer is the most common malignant tumor in females around the world, representing 25.2% of all cancers in women. About 1.7 million women were diagnosed with breast cancer worldwide in 2012 with a death rate of about 522,0001,2. The most frequently used methods in breast cancer screening are imaging methods, i.e. ultrasonography and mammography. A common feature of these methods is that they inherently involve the use of expensive and advanced equipment. The development of advanced computer systems allowed for the continuation of research started already in the 1980s3 and the use of contact thermography in breast cancer screening. The physiological basis for the application of thermography in medical imaging diagnostics is the so-called dermothermal effect related to higher metabolism rate around focal neoplastic lesion. This phenomenon can occur on breast surface as localized temperature anomalies4. The device developed by Braster is composed of a detector that works on the basis of thermotropic liquid crystals, image acquisition device and a computer system for image data processing and analysis. Production of the liquid crystal detector was based on a proprietary CLCF technology (Continuous Liquid Crystal Film). In 2014 Braster started feasibility study to prove that there is a potential for artificial intelligence in early breast cancer detection using Braster's proprietary technology. The aim of this study was to develop a computer system, using a client-server architecture, to an automatic interpretation of thermographic pictures created by the Braster devices.

  14. Bacteriological And Clinical Evaluation Of Twelve Cases Of Post ...

    African Journals Online (AJOL)

    Bacteriological And Clinical Evaluation Of Twelve Cases Of Post-Surgical Sepsis Of Odontogenic Tumours At A ... East African Medical Journal ... Intervention: Adequate review of patient\\'s medical history, bacteriological investigations and

  15. Vegetative propagation of twelve fodder tree species indigenous to ...

    African Journals Online (AJOL)

    Vegetative propagation of twelve fodder tree species indigenous to the Sahel, West Africa. Catherine Ky-Dembele, Jules Bayala, Antoine Kalinganire, Fatoumata Tata Traoré, Bréhima Koné, Alain Olivier ...

  16. Improvement of condition-based maintenance technology by utilization of thermography

    International Nuclear Information System (INIS)

    Shimada, Hiroki

    2004-01-01

    In the United States, condition-based maintenance technology comprising IR thermography (hereafter ''thermography'' for short) has been regarded in recent years as the established means for effectively improvement the performance of accident-preventive measures for nuclear power stations. As very few nuclear power plants in Japan have been utilizing the technology, measures for allowing power station personnel to use the technology with ease have been studied on an empirical basis. First, in view of improving the measuring efficiency to determine temperatures more accurately with a single measurement, principal factors affecting the measured temperature values have been analyzed. As a result, it has been found effective for accurate temperature measurement to make use of the table to radiation rates that have been determined for each facility coating specification by using a black body tape and to determine the measuring spot by avoiding rear heat sources (influence of reflection ratio) and background noise (influence of scattered light). Concurrently, as a result of determining the IR attenuation in the atmosphere, thermographic measurement has been found feasible without any significant attenuation as long as the distance is below 10 meters. Further, every power station facility (mainly electrical facilities) that is immune to thermography has been identified. These study results have been documented in the form of the ''Thermography Measurement Manual'' by also including in it the descriptions on abnormal thermal images and the judgment criteria at elevated temperatures that have been used in the United States. Based on these accomplishments, condition-based maintenance technology employing thermography has been applied to on-site investigation of nuclear power stations, and the effectiveness of thermography-aided accident-prevention has been demonstrated by detecting locally temperature rising spots of power cable joints. Moreover, with respect to maintenance

  17. External radiation as element of improvement infrared thermography measurements

    Directory of Open Access Journals (Sweden)

    Palomo, A.

    2000-09-01

    Full Text Available Infrared thermography is a very versatile non destructive technique which among other uses, can be applied to the study of moisture in buildings. However, this particular application can present some problems strictly related to the characteristics of the thermocamera device. In this case the available equipment works in the IR range of 2.5 to 5.6 μm. In this part of the spectrum, there exists a small and not very intense band of emission of the water molecules (approximately centered at 2.7 μm, in such a way that detection can be difficult through thermovision. In the present paper, a complementary technique to the IR thermography being able of favouring the emission of water on the mentioned band, has been developed. It enhances the capacity of detection of the instrument. Likewise, the process which takes place in the material has been numerically modelled.

    La termografía infrarroja es una técnica no destructiva, muy versátil, que, entre otras aplicaciones, tiene la de ser capaz de suministrar información en torno a la problemática de las humedades en la edificación. Sin embargo, esta aplicación concreta puede presentar algunos problemas directamente relacionados con las propias características de la termocámara utilizada. En el caso del presente trabajo el equipo de termografía infrarroja manejado trabaja en el rango del espectro IR comprendido entre 2,5 y 5,6 μm. En esta región del espectro existe una pequeña y no muy intensa banda de emisión de las moléculas de agua (aproximadamente centrada en 2,7 μm cuya detección puede no ser fácil a través de la termovisión. En el presente trabajo se ha desarrollado una técnica complementaria a la termografía infrarroja que es capaz de favorecer la intensidad de emisión del agua en la región del espectro antes mencionada. En definitiva, dicha técnica estimula la capacidad de detección de la termocámara. Adicionalmente, el proceso hídrico que tiene lugar en el

  18. Infrared thermography inspection and monitoring in oil and gas and petrochemical plant industry

    International Nuclear Information System (INIS)

    Shamsudin Sin Deraman

    2003-01-01

    Infrared thermography is an electronic technique that quite literally allows us to see thermal energy. The technique allows for the monitoring of temperatures and thermal patterns while the equipment is online and running under full load. Armed with guidelines of allowable operating temperature limits of the equipment, the technique may enhances company's, ?ability to predict equipment failure and plan corrective action before a costly shutdown, equipment damage, or personal injury occurs. Infrared thermography is an excellent condition monitoring tool to assist in the reduction of maintenance costs on mechanical, electrical and equipment. With this new capability plant maintenance personnel have recognized infrared thermography as one of the most versatile and effective condition monitoring tools available today. Infrared can be used on a wide variety of equipment including pumps, motors, bearings, pulleys, fans, drives, conveyors etc. This paper will explain the benefits of Infrared Thermography as a condition monitoring tool for plant equipment and mechanical systems and some examples of infrared thermography application is discussed. (Author)

  19. Automated diagnosis of dry eye using infrared thermography images

    Science.gov (United States)

    Acharya, U. Rajendra; Tan, Jen Hong; Koh, Joel E. W.; Sudarshan, Vidya K.; Yeo, Sharon; Too, Cheah Loon; Chua, Chua Kuang; Ng, E. Y. K.; Tong, Louis

    2015-07-01

    Dry Eye (DE) is a condition of either decreased tear production or increased tear film evaporation. Prolonged DE damages the cornea causing the corneal scarring, thinning and perforation. There is no single uniform diagnosis test available to date; combinations of diagnostic tests are to be performed to diagnose DE. The current diagnostic methods available are subjective, uncomfortable and invasive. Hence in this paper, we have developed an efficient, fast and non-invasive technique for the automated identification of normal and DE classes using infrared thermography images. The features are extracted from nonlinear method called Higher Order Spectra (HOS). Features are ranked using t-test ranking strategy. These ranked features are fed to various classifiers namely, K-Nearest Neighbor (KNN), Nave Bayesian Classifier (NBC), Decision Tree (DT), Probabilistic Neural Network (PNN), and Support Vector Machine (SVM) to select the best classifier using minimum number of features. Our proposed system is able to identify the DE and normal classes automatically with classification accuracy of 99.8%, sensitivity of 99.8%, and specificity if 99.8% for left eye using PNN and KNN classifiers. And we have reported classification accuracy of 99.8%, sensitivity of 99.9%, and specificity if 99.4% for right eye using SVM classifier with polynomial order 2 kernel.

  20. Infrared thermography of solid surfaces in a fire

    International Nuclear Information System (INIS)

    Meléndez, J; Foronda, A; Aranda, J M; López, F; López del Cerro, F J

    2010-01-01

    Fire resistance tests are commonplace in industry. The aerospace sector is particularly active in this area, since the behaviour of advanced materials, such as composites, when in a fire is not fully understood yet. Two of the main obstacles are the inherent difficulty of direct surface measurements in such a harsh environment (especially on the exposed side of the specimens) and the lack of spatial resolution of the usual measuring devices, namely thermocouples (TCs). This paper presents a way to overcome these problems by using an infrared (IR) camera to study the exposed side of composite plates exposed to fire. A method for minimizing the effect of the flame (thus making it as 'transparent' as possible) was developed, resulting in 2D temperature maps of the plate surface. The assumptions that the method relies on were verified by data analysis and ad hoc emission–transmission experiments. The errors associated with two slightly different versions of the method were studied, and comparisons with TC measurements were performed. It was found that the IR method provides better results than TCs, not only due to its spatial resolution capability but also because of the non-intrusive nature of IR thermography, as opposed to the local effects caused by TCs, which became evident during the experiments

  1. Monitoring Sintering Burn-Through Point Using Infrared Thermography

    Directory of Open Access Journals (Sweden)

    Francisco G. Bulnes

    2013-08-01

    Full Text Available Sintering is a complex industrial process that applies heat to fine particles of iron ore and other materials to produce sinter, a solidified porous material used in blast furnaces. The sintering process needs to be carefully adjusted, so that the combustion zone reaches the bottom of the material just before the discharge end. This is known as the burnthrough point. Many different parameters need to be finely tuned, including the speed and the quantities of the materials mixed. However, in order to achieve good results, sintering control requires precise feedback to adjust these parameters. This work presents a sensor to monitor the sintering burn-through point based on infrared thermography. The proposed procedure is based on the acquisition of infrared images at the end of the sintering process. At this position, infrared images contain the cross-section temperatures of the mixture. The objective of this work is to process this information to extract relevant features about the sintering process. The proposed procedure is based on four steps: key frame detection, region of interest detection, segmentation and feature extraction. The results indicate that the proposed procedure is very robust and reliable, providing features that can be used effectively to control the sintering process.

  2. Remote monitoring of breathing dynamics using infrared thermography.

    Science.gov (United States)

    Pereira, Carina Barbosa; Yu, Xinchi; Czaplik, Michael; Rossaint, Rolf; Blazek, Vladimir; Leonhardt, Steffen

    2015-11-01

    An atypical or irregular respiratory frequency is considered to be one of the earliest markers of physiological distress. In addition, monitoring of this vital parameter plays a major role in diagnosis of respiratory disorders, as well as in early detection of sudden infant death syndrome. Nevertheless, the current measurement modalities require attachment of sensors to the patient's body, leading to discomfort and stress. The current paper presents a new robust algorithm to remotely monitor breathing rate (BR) by using thermal imaging. This approach permits to detect and to track the region of interest (nose) as well as to estimate BR. In order to study the performance of the algorithm, and its robustness against motion and breathing disorders, three different thermal recordings of 11 healthy volunteers were acquired (sequence 1: normal breathing; sequence 2: normal breathing plus arbitrary head movements; and sequence 3: sequence of specific breathing patterns). Thoracic effort (piezoplethysmography) served as "gold standard" for validation of our results. An excellent agreement between estimated BR and ground truth was achieved. Whereas the mean correlation for sequence 1-3 were 0.968, 0.940 and 0.974, the mean absolute BR errors reached 0.33, 0.55 and 0.96 bpm (breaths per minute), respectively. In brief, this work demonstrates that infrared thermography is a promising, clinically relevant alternative for the currently available measuring modalities due to its performance and diverse remarkable advantages.

  3. Infrared thermography based studies on mobile phone induced heating

    Science.gov (United States)

    Lahiri, B. B.; Bagavathiappan, S.; Soumya, C.; Jayakumar, T.; Philip, John

    2015-07-01

    Here, we report the skin temperature rise due to the absorption of radio frequency (RF) energy from three handheld mobile phones using infrared thermography technique. Experiments are performed under two different conditions, viz. when the mobile phones are placed in soft touch with the skin surface and away from the skin surface. Additionally, the temperature rise of mobile phones during charging, operation and simultaneous charging and talking are monitored under different exposure conditions. It is observed that the temperature of the cheek and ear regions monotonically increased with time during the usage of mobile phones and the magnitude of the temperature rise is higher for the mobile phone with higher specific absorption rate. The increase in skin temperature is higher when the mobile phones are in contact with the skin surface due to the combined effect of absorption of RF electromagnetic power and conductive heat transfer. The increase in the skin temperature in non-contact mode is found to be within the safety limit of 1 °C. The measured temperature rise is in good agreement with theoretical predictions. The empirical equation obtained from the temperature rise on the cheek region of the subjects correlates well with the specific absorption rate of the mobile phones. Our study suggests that the use of mobile phones in non-contact mode can significantly lower the skin temperature rise during its use and hence, is safer compared to the contact mode.

  4. Induction Thermography for Surface Crack Detection and Depth Determination

    Directory of Open Access Journals (Sweden)

    Beate Oswald-Tranta

    2018-02-01

    Full Text Available In the last few years, induction thermography has been established as a non-destructive testing method for localizing surface cracks in metals. The sample to be inspected is heated with a short induced electrical current pulse, and the infrared camera records—during and after the heating pulse—the temperature distribution at the surface. Transforming the temporal temperature development for each pixel to phase information makes not only highly reliable detection of the cracks possible but also allows an estimation of its depth. Finite element simulations were carried out to investigate how the phase contrast depends on parameters such as excitation frequency, pulse duration, material parameters, crack depth, and inclination angle of the crack. From these results, generalized functions for the dependency of the phase difference on all these parameters were derived. These functions can be used as an excellent guideline as to how measurement parameters should be optimized for a given material to be able to detect cracks and estimate their depth. Several experiments on different samples were also carried out, and the results compared with the simulations showed very good agreement.

  5. Infrared thermography inspection methods applied to the target elements of W7-X divertor

    Energy Technology Data Exchange (ETDEWEB)

    Missirlian, M. [Association Euratom-CEA, CEA/DSM/DRFC, CEA/Cadarache, F-13108 Saint Paul Lez Durance (France)], E-mail: marc.missirlian@cea.fr; Traxler, H. [PLANSEE SE, Technology Center, A-6600 Reutte (Austria); Boscary, J. [Max-Planck-Institut fuer Plasmaphysik, Euratom Association, Boltzmannstr. 2, D-85748 Garching (Germany); Durocher, A.; Escourbiac, F.; Schlosser, J. [Association Euratom-CEA, CEA/DSM/DRFC, CEA/Cadarache, F-13108 Saint Paul Lez Durance (France); Schedler, B.; Schuler, P. [PLANSEE SE, Technology Center, A-6600 Reutte (Austria)

    2007-10-15

    The non-destructive examination (NDE) method is one of the key issues in developing highly loaded plasma-facing components (PFCs) for a next generation fusion devices such as W7-X and ITER. The most critical step is certainly the fabrication and the examination of the bond between the armour and the heat sink. Two inspection systems based on the infrared thermography methods, namely, the transient thermography (SATIR-CEA) and the pulsed thermography (ARGUS-PLANSEE), are being developed and have been applied to the pre-series of target elements of the W7-X divertor. Results obtained from qualification experiences performed on target elements with artificial calibrated defects allowed to demonstrate the capability of the two techniques and raised the efficiency of inspection to a level which is appropriate for industrial application.

  6. Infrared thermography inspection methods applied to the target elements of W7-X divertor

    International Nuclear Information System (INIS)

    Missirlian, M.; Traxler, H.; Boscary, J.; Durocher, A.; Escourbiac, F.; Schlosser, J.; Schedler, B.; Schuler, P.

    2007-01-01

    The non-destructive examination (NDE) method is one of the key issues in developing highly loaded plasma-facing components (PFCs) for a next generation fusion devices such as W7-X and ITER. The most critical step is certainly the fabrication and the examination of the bond between the armour and the heat sink. Two inspection systems based on the infrared thermography methods, namely, the transient thermography (SATIR-CEA) and the pulsed thermography (ARGUS-PLANSEE), are being developed and have been applied to the pre-series of target elements of the W7-X divertor. Results obtained from qualification experiences performed on target elements with artificial calibrated defects allowed to demonstrate the capability of the two techniques and raised the efficiency of inspection to a level which is appropriate for industrial application

  7. Primjena infracrvene termografije u kemijskom inženjerstvu (Application of Infrared Thermography in Chemical Engineering

    Directory of Open Access Journals (Sweden)

    Bolf, N.

    2004-12-01

    Full Text Available The infrared (IR thermography has become a powerful tool for basic and applied research in various scientific fields, varying from heat transfer to non-destructive testing, fluids and solids mechanics, biomedical application, environmental protection, etc. This paper has the intention to familiarize researchers and industrial staff with possibilities of applying IR thermography in the field of chemical engineering and process industry aiming in safe operating, saving of energy and environmental protection. A brief history of the IR thermography development, basic function principles of a modern system for thermographic measurements, and application overview have been shown. Following applications have been highlighted: nondestructive testing, preventive maintenance, and condition monitoring of process equipment. A special attention has been paid to industrial application regarding quality control and process control.

  8. Hybrid analysis for indicating patients with breast cancer using temperature time series.

    Science.gov (United States)

    Silva, Lincoln F; Santos, Alair Augusto S M D; Bravo, Renato S; Silva, Aristófanes C; Muchaluat-Saade, Débora C; Conci, Aura

    2016-07-01

    Breast cancer is the most common cancer among women worldwide. Diagnosis and treatment in early stages increase cure chances. The temperature of cancerous tissue is generally higher than that of healthy surrounding tissues, making thermography an option to be considered in screening strategies of this cancer type. This paper proposes a hybrid methodology for analyzing dynamic infrared thermography in order to indicate patients with risk of breast cancer, using unsupervised and supervised machine learning techniques, which characterizes the methodology as hybrid. The dynamic infrared thermography monitors or quantitatively measures temperature changes on the examined surface, after a thermal stress. In the dynamic infrared thermography execution, a sequence of breast thermograms is generated. In the proposed methodology, this sequence is processed and analyzed by several techniques. First, the region of the breasts is segmented and the thermograms of the sequence are registered. Then, temperature time series are built and the k-means algorithm is applied on these series using various values of k. Clustering formed by k-means algorithm, for each k value, is evaluated using clustering validation indices, generating values treated as features in the classification model construction step. A data mining tool was used to solve the combined algorithm selection and hyperparameter optimization (CASH) problem in classification tasks. Besides the classification algorithm recommended by the data mining tool, classifiers based on Bayesian networks, neural networks, decision rules and decision tree were executed on the data set used for evaluation. Test results support that the proposed analysis methodology is able to indicate patients with breast cancer. Among 39 tested classification algorithms, K-Star and Bayes Net presented 100% classification accuracy. Furthermore, among the Bayes Net, multi-layer perceptron, decision table and random forest classification algorithms, an

  9. Data combination of infrared thermography images and lock-in thermography images for NDE of plasma facing components

    International Nuclear Information System (INIS)

    Moysan, J.; Gueudre, C.; Corneloup, G.; Durocher, A.

    2006-01-01

    A pioneering activity has been developed by CEA and the European industry in the field of actively cooled high heat flux plasma facing components (PFC) from the very beginning of Tore Supra project. These components have been developed in order to enable a large power exhaust capability. The goal of this study is to improve the Non Destructive Evaluation (NDE) of these components. The difficulty encountered is the evaluation of the junction between a carbon and a metallic substrate. This was even more difficult when complex designs have to be implemented. A first NDE solution was based on the so called SATIR test. The method is based on infrared measurements of tile surface temperatures during a thermal transient produced by hot/cold water flowing in the heat sink cooling channel. In order to improve the definition of acceptance rules for the PFCs, a second NDE method based on Lock-in Thermography is developed. In this work we present how we can combine the two resulting images in order to accept or to reject a component. This prospective study allows improving the experimental setup and the definition of acceptance criteria. The experimental study was conducted on trial components for the Wendelstein 7X stellarator. The conclusions will also influence future non destructive projects dedicated to the ITER project. (orig.)

  10. Thermal properties of high-power diode lasers investigated by means of high resolution thermography

    International Nuclear Information System (INIS)

    Kozłowska, Anna; Maląg, Andrzej; Dąbrowska, Elżbieta; Teodorczyk, Marian

    2012-01-01

    In the present work, thermal effects in high-power diode lasers are investigated by means of high resolution thermography. Thermal properties of the devices emitting in the 650 nm and 808 nm wavelength ranges are compared. The different versions of the heterostructure design are analyzed. The results show a lowering of active region temperature for diode lasers with asymmetric heterostructure scheme with reduced quantum well distance from the heterostructure surface (and the heat sink). Optimization of technological processes allowed for the improvement of the device performance, e.g. reduction of solder non-uniformities and local defect sites at the mirrors which was visualized by the thermography.

  11. Emissivity-corrected power loss calibration for lock-in thermography measurements on silicon solar cells

    International Nuclear Information System (INIS)

    Kasemann, Martin; Walter, Benjamin; Meinhardt, Christoph; Ebser, Jan; Kwapil, Wolfram; Warta, Wilhelm

    2008-01-01

    This paper describes power loss calibration procedures with implemented emissivity correction. The determination of our emissivity correction matrix does neither rely on blackbody reference measurements nor on the knowledge of any sample temperatures. To describe the emissivity-corrected power calibration procedures in detail, we review the theory behind lock-in thermography and show experimentally that the lock-in signal is proportional to the power dissipation in the solar cell. Experiments show the successful application of our emissivity correction procedure, which significantly improves the informative value of lock-in thermography images and the reliability of the conclusions drawn from these images

  12. Evaluation of fiber reinforced polymers using active infrared thermography system with thermoelectric cooling modules

    Science.gov (United States)

    Chady, Tomasz; Gorący, Krzysztof

    2018-04-01

    Active infrared thermography is increasingly used for nondestructive testing of various materials. Properties of this method are creating a unique possibility to utilize it for inspection of composites. In the case of active thermography, an external energy source is usually used to induce a thermal contrast inside tested objects. The conventional heating methods (like halogen lamps or flash lamps) are utilized for this purpose. In this study, we propose to use a cooling unit. The proposed system consists of a thermal imaging infrared camera, which is used to observe the surface of the inspected specimen and a specially designed cooling unit with thermoelectric modules (the Peltier modules).

  13. Non-destructive Testing by Infrared Thermography Under Random Excitation and ARMA Analysis

    Science.gov (United States)

    Bodnar, J. L.; Nicolas, J. L.; Candoré, J. C.; Detalle, V.

    2012-11-01

    Photothermal thermography is a non-destructive testing (NDT) method, which has many applications in the field of control and characterization of thin materials. This technique is usually implemented under CW or flash excitation. Such excitations are not adapted for control of fragile materials or for multi-frequency analysis. To allow these analyses, in this article, the use of a new control mode is proposed: infrared thermography under random excitation and auto regressive moving average analysis. First, the principle of this NDT method is presented. Then, the method is shown to permit detection, with low energy constraints, of detachments situated in mural paintings.

  14. The consistency of thermographic findings in breast screening

    International Nuclear Information System (INIS)

    Pflanzer, K.; Kleedorfer, D.; Pflanzer, D.; Fochem, K.

    1983-01-01

    Thermography is a valuable complementary method in breast examination, but is not a suitable screening method. However, the results of control investigations in 200 females who were reexamined after at least two years, showed no change in the thermographic pattern in 87.5% of the women. In 10.5% the change in thermogram was due to pathological changes, whilst no explanation could be found in only 2% of cases. This high stability rate of the thermograms permits an alternative procedure: If, one year after a basic examination which includes clinical investigation, mammography and thermography, the thermographic pattern is identical with the first, no mammography is necessary. On the occasion of the next control, mammography should be carried out again at the time of the subsequent control examination. This schedule permits a reduction in irradiation without reducing the security of diagnosis. (Author)

  15. Infrared thermography method for fast estimation of phase diagrams

    Energy Technology Data Exchange (ETDEWEB)

    Palomo Del Barrio, Elena [Université de Bordeaux, Institut de Mécanique et d’Ingénierie, Esplanade des Arts et Métiers, 33405 Talence (France); Cadoret, Régis [Centre National de la Recherche Scientifique, Institut de Mécanique et d’Ingénierie, Esplanade des Arts et Métiers, 33405 Talence (France); Daranlot, Julien [Solvay, Laboratoire du Futur, 178 Av du Dr Schweitzer, 33608 Pessac (France); Achchaq, Fouzia, E-mail: fouzia.achchaq@u-bordeaux.fr [Université de Bordeaux, Institut de Mécanique et d’Ingénierie, Esplanade des Arts et Métiers, 33405 Talence (France)

    2016-02-10

    Highlights: • Infrared thermography is proposed to determine phase diagrams in record time. • Phase boundaries are detected by means of emissivity changes during heating. • Transition lines are identified by using Singular Value Decomposition techniques. • Different binary systems have been used for validation purposes. - Abstract: Phase change materials (PCM) are widely used today in thermal energy storage applications. Pure PCMs are rarely used because of non adapted melting points. Instead of them, mixtures are preferred. The search of suitable mixtures, preferably eutectics, is often a tedious and time consuming task which requires the determination of phase diagrams. In order to accelerate this screening step, a new method for estimating phase diagrams in record time (1–3 h) has been established and validated. A sample composed by small droplets of mixtures with different compositions (as many as necessary to have a good coverage of the phase diagram) deposited on a flat substrate is first prepared and cooled down to ambient temperature so that all droplets crystallize. The plate is then heated at constant heating rate up to a sufficiently high temperature for melting all the small crystals. The heating process is imaged by using an infrared camera. An appropriate method based on singular values decomposition technique has been developed to analyze the recorded images and to determine the transition lines of the phase diagram. The method has been applied to determine several simple eutectic phase diagrams and the reached results have been validated by comparison with the phase diagrams obtained by Differential Scanning Calorimeter measurements and by thermodynamic modelling.

  16. Using aerial infrared thermography to detect utility theft of service

    Science.gov (United States)

    Stockton, Gregory R.; Lucas, R. Gillem

    2012-06-01

    Natural gas and electric utility companies, public utility commissions, consumer advocacy groups, city governments, state governments and the federal government United States continue to turn a blind eye towards utility energy theft of service which we conservatively estimate is in excess of 10 billion a year. Why? Many in the United States have exhausted their unemployment benefits. The amounts for federal funding for low income heating assistance programs (LIHEAP) funds were cut by nearly 40% for 2012 to 3.02 billion. "At peak funding ($5.1 billion in 2009), the program was national in scale but still only had enough resources to support roughly 1/4 of the eligible households.i" Contributions to charities are down and the number of families below the poverty line who are unable to pay to heat their houses continues to rise. Many of the less fortunate in our society now consider theft and fraud to be an attractive option for their supply of natural gas and/or electricity. A record high mild winter in 2011-2012 coupled with 10-year low natural gas prices temporarily obscured the need for low income heating assistance programs (LIHEAPs) from the news and federal budgets, but cold winters will return. The proliferation of smart meters and automated meter infrastructures across our nation can do little to detect energy theft because the thieves can simply by-pass the meters, jumper around the meters and/or steal meters from abandoned houses and use them. Many utility systems were never set-up to stop these types of theft. Even with low-cost per identified thief method using aerial infrared thermography, utilities continue to ignore theft detection.

  17. Ten colour photometry of twelve Ap-stars

    International Nuclear Information System (INIS)

    Musielok, B.; Lange, D.; Schoeneich, W.; Hildebrandt, G.; Zelwanowa, E.; Hempelmann, A.; Salmanov, G.

    1980-01-01

    Ten-colour photoelectric observations are presented for twelve Ap-stars. Improved ephemeris for seven of them is given. Phase relations between the light curves and line intensity variations are discussed. The problem of the electromagnetic flux conctancy of IOTA Cas is approached from a qualitative point of view. (author)

  18. Education and Development: Twelve Considerations for Transformative Practice

    Science.gov (United States)

    VanBalkom, W. Duffie; Eastham, Sarada

    2011-01-01

    Twelve factors that are essential to consider when embarking on the process of transformative development are examined in the context of international development programming in education and training. Each factor raises a number of questions for the deliberations of policy makers, development practitioners, scholars, international educators,…

  19. Secondary Textbook Review: English, Grades Nine through Twelve.

    Science.gov (United States)

    California State Dept. of Education, Sacramento.

    This book is intended as a resource for teachers and curriculum developers who select textbooks for secondary English courses. It includes a compilation of 32 factual textbook reviews obtained from the application of a review instrument, which was based on the California "Model Curriculum Standards: Grades Nine through Twelve, English…

  20. Safety of superconducting fusion magnets: twelve problem areas

    International Nuclear Information System (INIS)

    Turner, L.R.

    1979-01-01

    Twelve problem areas of superconducting magnets for fusion reaction are described. These are: quench detection and energy dump, stationary normal region of conductor, current leads, electrical arcing, electrical shorts, conductor joints, forces from unequal currents, eddy current effects, cryostat rupture, vacuum failure, fringing field and instrumentation for safety. Priorities among these areas are suggested

  1. Safety of superconducting fusion magnets: twelve problem areas

    International Nuclear Information System (INIS)

    Turner, L.R.

    1979-01-01

    Twelve problem areas of superconducting magnets for fusion reaction are described. These are: Quench Detection and Energy Dump, Stationary Normal Region of Conductor, Current Leads, Electrical Arcing, Electrical Shorts, Conductor Joints, Forces from Unequal Currents, Eddy Current Effects, Cryostat Rupture, Vacuum Failure, Fringing Field and Instrumentation for Safety. Priorities among these areas are suggested

  2. Breast Pain

    Science.gov (United States)

    ... result in the development of breast cysts. Breast trauma, prior breast surgery or other factors localized to the breast can lead to breast pain. Breast pain may also start outside the breast — in the chest wall, muscles, joints or heart, for example — and ...

  3. The benefits and harms of screening for cancer with a focus on breast screening

    DEFF Research Database (Denmark)

    Brodersen, John; Juhl Jørgensen, Karsten; Gøtzsche, Peter C.

    2010-01-01

    . The effects of routine clinical breast examination are unknown, but considering the results of the breast self-examination trials, it is likely that it is harmful. The effects of screening for breast cancer with thermography, ultrasound or magnetic resonance imaging are unknown. It is not clear whether......The balance between benefits and harms is delicate for cancer screening programs. By attending screening with mammography some women will avoid dying from breast cancer or receive less aggressive treatment. But many more women will be overdiagnosed, receive needless treatment, have a false...... and will be treated unnecessarily. Furthermore, more than 200 women will experience substantial psychosocial distress for months because of false-positive findings. Regular breast self-examination does not reduce breast cancer mortality, but doubles the number of biopsies, and it therefore cannot be recommended...

  4. Cancer diagnosis in a ''breast clinic''

    International Nuclear Information System (INIS)

    Ghys, R.

    1987-01-01

    Conflicting opinions have been expressed in the world literature over the last 15 years about the value of radiological techniques in breast cancer diagnosis. We reviewed 111 breast cancers which we diagnosed between 1971 and 1985, in unselected patients, by the combined use of palpation, thermography and mammography, complemented, since 1980, by diaphanoscopy. Considerable clinical experience is necessary to interpret both mammograms and thermograms. Each of these approaches, when rated independently, has a very high false negative rate ranging from 41% for clinical examination to 32% for mammography. In cases which are not clinically obvious, diaphanoscopy ''retrieves'' the most cancers, with thermography a close second (definitely malignant in 35% of the cases over the whole age range). Mammography comes third and its efficacy drops to 12.5% in premenopausal women. However, by combining this information with the one derived from anamnesis, the ACDTM scoring system gives us a false negative rate - before biopsy - of 5.5% and a false positive rate of <1%. This approach also drastically reduces the number of unnecessary biopsies

  5. Development of an original active thermography method adapted to ITER plasma facing components control

    Energy Technology Data Exchange (ETDEWEB)

    Durocher, A.; Vignal, N.; Escourbiac, F.; Farjon, J.L.; Schlosser, J. [CEA Cadarache, Dept. de Recherches sur la Fusion Controlee, 13 - Saint-Paul-lez-Durance (France); Cismondi, F. [Toulon Univ., 83 - La Garde (France)

    2004-07-01

    Among all Non-Destructive Examinations (NDE), active infrared thermography is becoming recognised as a technique available today for improving quality control of many materials and structures involved in heat transfer. The infrared thermography allows to characterise the bond between two materials having different thermal physical properties. In order to increase the defect detection limit of the SATIR test bed, several possibilities have been evaluated to improve the infrared thermography inspection. The implementation in 2003 of a micro-bolometer camera and the improving of the thermo-signal process allowed to increase considerably the detection sensitivity of the SATIR facility. The quality, the spatial stability of infrared image and the detection of edge defect have been also improved. The coupling on the same test bed of SATIR method with a lock-in thermography will be evaluated in this paper. An improvement of the global reliability is expected by data merging produced by the two thermal excitation sources. A new enhanced facility named SATIRPACA has been designed for the full Non Destructive Examination of the High Heat Flux ITER components taking into account these main improvements. These systematic acceptance tests obviously need tools for quality control of critical parts. (authors)

  6. The role of capillaroscopy and thermography in the assessment and management of Raynaud's phenomenon.

    Science.gov (United States)

    Herrick, Ariane L; Murray, Andrea

    2018-05-01

    Most patients with Raynaud's phenomenon (RP) have "benign" primary RP (PRP), but a minority have an underlying cause, for example a connective tissue disease such as systemic sclerosis (SSc). Secondary RP can be associated with structural as well as functional digital vascular changes and can be very severe, potentially progressing to digital ulceration or gangrene. The first step in management is to establish why the patient has RP. This short review discusses the role of nailfold capillaroscopy and thermography in the assessment of RP. Nailfold capillaroscopy examines microvascular structure, which is normal in PRP but abnormal in most patients with SSc: the inclusion of abnormal nailfold capillaries into the 2013 classification criteria for SSc behoves clinicians diagnosing connective tissue disease to be familiar with the technique. For those without access to the gold standard of high magnification videocapillaroscopy, a low magnification dermatoscope or USB microscope can be used. Thermography measures surface temperature and is therefore an indirect measure of blood blow, assessing digital vascular function (abnormal in both PRP and SSc). Until now, the use of thermography has been mainly confined to specialist centres and used mainly in research: this may change with development of mobile phone thermography. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Nondestructive Testing of Ceramic Hip Joint Implants with Laser Spot Thermography

    Directory of Open Access Journals (Sweden)

    Roemer J.

    2017-12-01

    Full Text Available The paper presents an application of laser spot thermography for damage detection in ceramic samples with surface breaking cracks. The measurement technique is an active thermographic approach based on an external heat delivery to a test sample, by means of a laser pulse, and signal acquisition by an infrared camera. Damage detection is based on the analysis of surface temperature distribution near the exciting laser spot. The technique is nondestructive, non-contact and allows for full-field measurements. Surface breaking cracks are a very common type of damage in ceramic materials that are introduced in the manufacturing process or during the service period. This paper briefly discusses theoretical background of laser spot thermography, describes the experimental test rig and signal processing methods involved. Damage detection results obtained with laser spot thermography are compared with reference measurements obtained with vibrothermography. This is a different modality of active thermography, that has been previously proven effective for this type of damage. We demonstrate that both measurement techniques can be effectively used for damage detection and quality control applications of ceramic materials.

  8. Current injection phase thermography for low-velocity impact damage identification in composite laminates

    International Nuclear Information System (INIS)

    Grammatikos, S.A.; Kordatos, E.Z.; Matikas, T.E.; David, C.; Paipetis, A.S.

    2014-01-01

    Highlights: • A novel Current injection phase thermography NDE method has been developed. • Blind impact damage has been successfully detected in composite laminates. • Carbon nanotubes enhance detection by improving of through thickness conductivity. • Detection is feasible with considerably less energy than for IR excited thermography. - Abstract: An innovative non-destructive evaluation (NDE) technique is presented based on current stimulated thermography. Modulated electric current is injected to Carbon Fibre Reinforced Plastics (CFRP) laminates as an external source of thermal excitation. Pulsed Phase Thermography (PPT) is concurrently employed to identify low velocity impact induced (LVI) damage. The efficiency of the proposed method is demonstrated for both plain and with Carbon Nanotubes (CNTs) modified laminates, which are subjected to low-velocity impact damaged composite laminates at different energy levels. The presence of the nano reinforcing phase is important in achieving a uniform current flow along the laminate, as it improves the through thickness conductivity. The acquired thermographs are compared with optical PPT, C-scan images and Computer Tomography (CT) representations. The typical energy input for successful damage identification with current injection is three to four orders of magnitude less compared to the energy required for optical PPT

  9. Study of cost benefits of identification of non-problems with infrared thermography

    International Nuclear Information System (INIS)

    Evans, J.P.; Wurzbach, R.N.

    1994-01-01

    Justifying the costs of starting and maintaining an in-house infrared thermography program is essential in ensuring continued funding and sponsorship. Cost benefit studies, whether brief and general, or strictly formalized, tend to focus on costs associated with projected equipment failure and production downtime. While these numbers can be quite dramatic, their validity rests on acceptance of the predicted failure which is inevitably the subject of some conjecture. Sometimes overlooked in these cost benefit analyses is the savings from avoided work through the optimization of routine time-directed tasks and the identification of non-problems. This includes condition based maintenance superseding preventive maintenance, and the value of including thermography in the troubleshooting process of known or suspected equipment performance problems. Using thermography inspection results to direct maintenance to the root cause of a performance problem can shorten downtime and eliminate unnecessary work and material expenditure. Cost benefit analysis of this type of inspection can be considered ''hard dollars,'' that is to say, that the money saved can be accurately calculated based on the repair costs which would normally have taken place if the information from the infrared thermography inspection had not been available. This type of savings, when presented to the administrator of the predictive maintenance program or the head of the maintenance department, represents real savings which are uncontestable in contrast to the postulated failure scenario calculations. This cost benefit analysis was done for PECO's nuclear units

  10. A new measurement method of coatings thickness based on lock-in thermography

    Science.gov (United States)

    Zhang, Jin-Yu; Meng, Xiang-bin; Ma, Yong-chao

    2016-05-01

    Coatings have been widely used in modern industry and it plays an important role. Coatings thickness is directly related to the performance of the functional coatings, therefore, rapid and accurate coatings thickness inspection has great significance. Existing coatings thickness measurement method is difficult to achieve fast and accurate on-site non-destructive coatings inspection due to cost, accuracy, destruction during inspection and other reasons. This paper starts from the introduction of the principle of lock-in thermography, and then performs an in-depth study on the application of lock-in thermography in coatings inspection through numerical modeling and analysis. The numerical analysis helps explore the relationship between coatings thickness and phase, and the relationship lays the foundation for accurate calculation of coatings thickness. The author sets up a lock-in thermography inspection system and uses thermal barrier coatings specimens to conduct an experiment. The specimen coatings thickness is measured and calibrated to verify the quantitative inspection. Experiment results show that the lock-in thermography method can perform fast coatings inspection and the inspection accuracy is about 95%. Therefore, the method can meet the field testing requirements for engineering projects.

  11. Quantitative thermography and methods for in-situ determination of heat losses from district heating networks

    Energy Technology Data Exchange (ETDEWEB)

    Boehm, B. [ed.

    1996-11-01

    The course and seminar summarizing application of infrared thermography in district heating systems control gathered Danish specialists with 5 contributions on the subject. Maintenance of the heat distribution pipelines and thermographic inspection of the systems are essential in order to avoid heat losses. (EG)

  12. Infra-red thermography for detecting frost pockets on snow-covered clear-fellings

    International Nuclear Information System (INIS)

    Mattsson, J.O.; Odin, H.; Palenius, H.P.

    1983-01-01

    The purpose of the investigation was to find out if IR-thermography from aircraft could be a useful method for registration and studies of regional variation of frost exposition within an area and of distribution of frost risks within individual felling areas. The technique, which was successful, has up till now not been utilized in Sweden for such studies in woodland

  13. Infrared Thermography Characterization of Defects in Seamless Pipes Using an Infrared Reflector

    International Nuclear Information System (INIS)

    Park, Hee Sang; Choi, Man Yong; Park, Jeong Hak; Lee, Jae Jung; Kim, Won Tae; Lee, Bo Young

    2012-01-01

    Infrared thermography uses infrared energy radiated from any objects above absolute zero temperature, and the range of its application has been constantly broadened. As one of the active test techniques detecting radiant energy generated when energy is applied to an object, ultrasound infrared thermography is a method of detecting defects through hot spots occurring at a defect area when 15-100 kHz of ultrasound is excited to an object. This technique is effective in detecting a wide range affected by ultrasound and vibration in real time. Especially, it is really effective when a defect area is minute. Therefore, this study conducted thermography through lock-in signal processing when an actual defect exists inside the austenite STS304 seamless pipe, which simulates thermal fatigue cracks in a nuclear power plant pipe. With ultrasound excited, this study could detect defects on the rear of a pipe by using an aluminium reflector. Besides, by regulating the angle of the aluminium reflector, this study could detect both front and rear defects as a single infrared thermography image.

  14. Development of an original active thermography method adapted to ITER plasma facing components control

    International Nuclear Information System (INIS)

    Durocher, A.; Vignal, N.; Escourbiac, F.; Farjon, J.L.; Schlosser, J.; Cismondi, F.

    2004-01-01

    Among all Non-Destructive Examinations (NDE), active infrared thermography is becoming recognised as a technique available today for improving quality control of many materials and structures involved in heat transfer. The infrared thermography allows to characterise the bond between two materials having different thermal physical properties. In order to increase the defect detection limit of the SATIR test bed, several possibilities have been evaluated to improve the infrared thermography inspection. The implementation in 2003 of a micro-bolometer camera and the improving of the thermo-signal process allowed to increase considerably the detection sensitivity of the SATIR facility. The quality, the spatial stability of infrared image and the detection of edge defect have been also improved. The coupling on the same test bed of SATIR method with a lock-in thermography will be evaluated in this paper. An improvement of the global reliability is expected by data merging produced by the two thermal excitation sources. A new enhanced facility named SATIRPACA has been designed for the full Non Destructive Examination of the High Heat Flux ITER components taking into account these main improvements. These systematic acceptance tests obviously need tools for quality control of critical parts. (authors)

  15. Validation of infrared thermography in serotonin-induced itch model in rats

    DEFF Research Database (Denmark)

    Dagnæs-Hansen, Frederik; Jasemian, Yousef; Gazerani, Parisa

    The number of scratching bouts is generally used as a standard method in animal models of itch. The aim of the present study was to validate the application of infrared thermography (IR-Th) in a serotonin-induced itch model in rats. Adult Sprague-Dawley male rats (n = 24) were used in 3 consecuti...

  16. Early detection of fires by means of thermography; Frueherkennung von Braenden mit Thermografie

    Energy Technology Data Exchange (ETDEWEB)

    Krauss, Matthias; Doeppner, Joerg; Pohl, Gisbert; Mahler, Guido; Dammass, Gunnar; Wendland, Georg [InfraTec GmbH, Dresden (Germany)

    2012-11-01

    The authors of the contribution under consideration report on the physical and technical fundamentals of an early detection of fires by means of thermal imaging. Hereupon, the technical implementation of these fundamentals into a modular automatic monitoring system by thermography is described. The authors report on practical experiences of this monitoring system.

  17. Application of infrared thermography for the analysis of rewarming in patients with cold intolerance

    NARCIS (Netherlands)

    Ruijs, A.C.J.; Jaquet, J.B.; Brandsma, M.; Daanen, H.A.M.; Hovius, S.E.R.

    2008-01-01

    Cold intolerance is a serious long-term problem after injury to the ulnar and median nerves, and its pathophysiology is unclear. We investigated the use of infrared thermography for the analysis of thermoregulation after injury to peripheral nerves. Four patients with injuries to the ulnar nerve and

  18. Online Chip Temperature Monitoring Using υce-Load Current and IR Thermography

    DEFF Research Database (Denmark)

    Ghimire, Pramod; Pedersen, Kristian Bonderup; Trintis, Ionut

    2015-01-01

    This paper presents on-state collector-emitter voltage (υce, on)-load current (Ic) method to monitor chip temperature on power insulated gate bipolar transistor (IGBT) modules in converter operation. The measurement method is also evaluated using infrared (IR) thermography. Temperature dependencies...

  19. Focal plane array based infrared thermography in fine physical experiment

    International Nuclear Information System (INIS)

    Vainer, Boris G

    2008-01-01

    By two examples of dissimilar physical phenomena causing thermophysical effects, the unique capabilities of one of the up-to-date methods of experimental physics-focal plane array (FPA) based infrared (IR) thermography (IRT), are demonstrated distinctly. Experimenters inexperienced in IRT can grasp how this method provides a means for combining real-time visualization with quantitative analysis. A narrow-band short-wavelength IR camera was used in the experiments. It is discussed and stated that IRT is best matched and suited to the next two test conditions-when a heated specimen is thin and when heat is generated in the immediate region of a surface of a solid. The first prerequisite is realized in the search for directional patterns of combined low-power radiation sources with the use of the IRT-aided method. The second one is realized in studies of water vapour adsorption on uneven (irregular) surfaces of solid materials. With multiple swatches taken from a set of different fabrics and used as experimental samples, a sharp distinction between adsorptivities of their surfaces is strikingly illustrated by IRT time-domain measurements exhibiting the associated thermal effect ranging within an order of magnitude. It is justified that the described IRT-aided test can find practical implementation at least in the light industry. Emissivities of different fabrics are evaluated experimentally with the described reflection method based on the narrow spectral range of IRT. On the basis of direct IR observations, attention is paid to the need for close control over the surface temperature increase while the adsorption isotherms are being measured. Sensitivity of the FPA-based IRT method, as applied to examine the kinetics of initial stages of adsorption of gaseous molecules on the solid surface, is evaluated analytically and quantitatively. The relationship between the amount of adsorbate and the measurable excess of adsorbent temperature is found. It is discovered that

  20. Twelve years of fireworks market surveillance in France

    OpenAIRE

    Branka , Ruddy

    2012-01-01

    International audience; In the view of market surveillance, more than 4400 fireworks have been taken on the spot by sworn people or bought on the market in France since 1999 for inspection purposes. This paper presents the market surveillance sampling evolution during twelve years, carried out by the PYRO unit of the Accidental Risks Division of INERIS as testing body ; the related measures implemented : additional audits in importer plants, interlaboratory tests for guarantying the reliabili...

  1. Twelve Theses on Reactive Rules for the Web

    OpenAIRE

    Bry, François; Eckert, Michael

    2006-01-01

    Reactivity, the ability to detect and react to events, is an essential functionality in many information systems. In particular, Web systems such as online marketplaces, adaptive (e.g., recommender) sys- tems, and Web services, react to events such as Web page updates or data posted to a server. This article investigates issues of relevance in designing high-level programming languages dedicated to reactivity on the Web. It presents twelve theses on features desira...

  2. Hidden twelve-dimensional super Poincare symmetry in eleven dimensions

    International Nuclear Information System (INIS)

    Bars, Itzhak; Deliduman, Cemsinan; Pasqua, Andrea; Zumino, Bruno

    2004-01-01

    First, we review a result in our previous paper, of how a ten-dimensional superparticle, taken off-shell, has a hidden eleven-dimensional super Poincare symmetry. Then, we show that the physical sector is defined by three first-class constraints which preserve the full eleven-dimensional symmetry. Applying the same concepts to the eleven-dimensional superparticle, taken off-shell, we discover a hidden twelve-dimensional super Poincare symmetry that governs the theory

  3. Spatially resolved determination of the short-circuit current density of silicon solar cells via lock-in thermography

    International Nuclear Information System (INIS)

    Fertig, Fabian; Greulich, Johannes; Rein, Stefan

    2014-01-01

    We present a spatially resolved method to determine the short-circuit current density of crystalline silicon solar cells by means of lock-in thermography. The method utilizes the property of crystalline silicon solar cells that the short-circuit current does not differ significantly from the illuminated current under moderate reverse bias. Since lock-in thermography images locally dissipated power density, this information is exploited to extract values of spatially resolved current density under short-circuit conditions. In order to obtain an accurate result, one or two illuminated lock-in thermography images and one dark lock-in thermography image need to be recorded. The method can be simplified in a way that only one image is required to generate a meaningful short-circuit current density map. The proposed method is theoretically motivated, and experimentally validated for monochromatic illumination in comparison to the reference method of light-beam induced current.

  4. Skin vasomotor hemiparesis followed by overactivity: characteristic thermography findings in a patient with Horner syndrome due to spinal cord infarction.

    Science.gov (United States)

    Kobayashi, Makoto

    2016-04-01

    We present a 21-year-old female with Horner syndrome due to spinal cord infarction. In this patient, infrared thermography revealed a hemibody skin temperature increase followed by excessive focal decreases, indicating skin vasomotor hemiparesis and overactivity.

  5. Fatigue crack detection on structural steel members by using ultrasound excited thermography

    International Nuclear Information System (INIS)

    Plum, Robin Marc

    2015-01-01

    In the field of non-destructive testing (NDT), ultrasound excited thermography has been recognised as a promising technique that was successfully applied to metals, fibre composites and many more engineering materials in order to detect cracks, delaminations and other types of internal flaws. Dating back to the late 1970s, the idea of high-frequency vibration excitation of structural members combined with monitoring the surface temperature by means of infrared thermography aims at the localised energy dissipation at defect regions and its thermal detection. The purpose of this thesis is to investigate the potential use of ultrasound excited thermography for detecting surface breaking fatigue cracks in thick-walled components relevant to steel construction. The presented research is motivated by a lack of fast and imaging crack detection methods in the field and the growing acceptance and technological progress of active thermography techniques. After introducing the concept of ultrasound excited thermography or vibrothermography, its current state of the art is described by means of a comprehensive literature review focusing on research activities towards crack detection on metals. Owing to the interdisciplinarity of the test method, all relevant technical subdisciplines from the excitation of plate vibrations via potential heat generation mechanisms and heat transfer to infrared thermography are outlined. The experimental work starts with the manufacture and fatigue loading of suitable plate specimens made from low-carbon steel S355, mostly in the high cycle fatigue regime, to generate throughthickness cracks with specified depths. Using a modified high-power ultrasonic welding generator, basic dependencies of the defect heating on frequency, coupling location and excitation duration are clarified at first. Besides of an estimation of realistic detection limits depending on the plate thickness, main issues such as the relation between vibration intensity and

  6. Fatigue crack detection on structural steel members by using ultrasound excited thermography

    Energy Technology Data Exchange (ETDEWEB)

    Plum, Robin Marc

    2015-07-01

    In the field of non-destructive testing (NDT), ultrasound excited thermography has been recognised as a promising technique that was successfully applied to metals, fibre composites and many more engineering materials in order to detect cracks, delaminations and other types of internal flaws. Dating back to the late 1970s, the idea of high-frequency vibration excitation of structural members combined with monitoring the surface temperature by means of infrared thermography aims at the localised energy dissipation at defect regions and its thermal detection. The purpose of this thesis is to investigate the potential use of ultrasound excited thermography for detecting surface breaking fatigue cracks in thick-walled components relevant to steel construction. The presented research is motivated by a lack of fast and imaging crack detection methods in the field and the growing acceptance and technological progress of active thermography techniques. After introducing the concept of ultrasound excited thermography or vibrothermography, its current state of the art is described by means of a comprehensive literature review focusing on research activities towards crack detection on metals. Owing to the interdisciplinarity of the test method, all relevant technical subdisciplines from the excitation of plate vibrations via potential heat generation mechanisms and heat transfer to infrared thermography are outlined. The experimental work starts with the manufacture and fatigue loading of suitable plate specimens made from low-carbon steel S355, mostly in the high cycle fatigue regime, to generate throughthickness cracks with specified depths. Using a modified high-power ultrasonic welding generator, basic dependencies of the defect heating on frequency, coupling location and excitation duration are clarified at first. Besides of an estimation of realistic detection limits depending on the plate thickness, main issues such as the relation between vibration intensity and

  7. Millipedes (Diplopoda of twelve caves in Western Mecsek, Southwest Hungary

    Directory of Open Access Journals (Sweden)

    Angyal, D.

    2013-11-01

    Full Text Available Twelve caves of Western Mecsek, Southwest Hungary were examined between September 2010 and April 2013from the millipede (Diplopoda faunistical point of view. Ten species were found in eight caves, which consistedeutroglophile and troglobiont elements as well. The cave with the most diverse fauna was the Törökpince Sinkhole, while thetwo previously also investigated caves, the Abaligeti Cave and the Mánfai-kőlyuk Cave provided less species, which couldbe related to their advanced touristic and industrial utilization.

  8. Twelve tips for creating an academic teaching portfolio.

    Science.gov (United States)

    Little-Wienert, Kim; Mazziotti, Mark

    2018-01-01

    An academic teaching portfolio is not only a requirement at many academic teaching institutions, but it is also important in a medical educator's growth and development through documentation, reflection, evaluation, and change. Creating an academic portfolio may appear daunting at first but with careful advanced preparation, organized evidence collection of your educational work, proof of scholarship, and thorough documentation of self-reflection and change, you can produce a successful product that accurately represents your educational beliefs, accomplishments, and growth throughout your career. This article provides medical educators with twelve steps for creating a successful academic teaching portfolio.

  9. Safety of superconducting fusion magnets: twelve problem areas

    International Nuclear Information System (INIS)

    Turner, L.R.

    1979-05-01

    Twelve problem areas of superconducting magnets for fusion reaction are described. These are: Quench Detection and Energy Dump, Stationary Normal Region of Conductor, Current Leads, Electrical Arcing, Electrical Shorts, Conductor Joints, Forces from Unequal Currents, Eddy Current Effects, Cryostat Rupture, Vacuum Failure, Fringing Field and Instrumentation for Safety. Each is described under the five categories: Identification and Definition, Possible Safety Effects, Current Practice, Adequacy of Current Practice for Fusion Magnets and Areas Requiring Further Analytical and Experimental Study. Priorities among these areas are suggested; application is made to the Large Coil Project at Oak Ridge National Laboratory

  10. Interim advice concerning the early detection of breast cancer

    International Nuclear Information System (INIS)

    1982-01-01

    The incidence of breast cancer in the Netherlands and the methods of diagnosis and treatment are outlined. A systematic screening of the total female population would result in a number of breast cancers being found at a relatively early stage. The advantages and disadvantages of five methods of screening are discussed: breast self-examination by women, palpation by doctor or para-medical personnel, mammography, ultrasound and thermography. It is concluded that mammography currently appears to be the best method. The risk that the X-rays might cause cancer is negligible. Two large screening projects in the Netherlands are described and the preliminary results discussed. In the appendices, a number of aspects such as the current projects in the Netherlands, the risks of ionizing radiation, and the attitudes and response of women invited for screening, are elaborated upon. A discussion session between an advisory committee and a number of Dutch and foreign experts is also presented (in English). (Auth.)

  11. Is it possible to revive the flagging interest in thermography for neurology?

    Science.gov (United States)

    Stulin, Igor D.

    1993-11-01

    The paper describes the results of twenty-years of experience in applying thermography (thermal imaging) in routine and urgent neurology, based on the study of more than ten thousand patients. Stress is laid on the fact that thermography is of great significance for diagnosing dextrocerebral hemorrhagic insult with a manifestation of pronounced hemihypothermia in the paralyzed limbs, identifying paraorbital hyperthermia on the side of rhinogenous cerebral abscess, for instrumental registration of transitory heat-up of the nasolabial region in the case of patients suffering from hypertensive nasal bleeding. Much attention is given to diagnosis of intra- and extracerebral phlebopathy in urgent neurology -- early diagnosis of iatrogenic catheterization phlebitis, interference with the venous return in the paralyzed lower limb. The novelty here is the employment of telethermography for complex diagnosis of cerebral death.

  12. A photovoltaic module diagnostic setup for lock-in-thermography and lock-in electroluminescence imaging

    DEFF Research Database (Denmark)

    Parikh, Harsh; Spataru, Sergiu; Sera, Dezso

    2018-01-01

    Electroluminescence (EL) imaging and infrared (IRT) thermography techniques have become indispensable tools in recent years for health diagnostic of PV modules in solar industry application. Complementary to these imaging methods, lock-in techniques can effectively remove noise by periodically...... modulating the input signal and averaging it over a desired number of periods. We propose a combined lock-in EL and lock-in IRT diagnostic setup for accurate analysis of different types of faults occurring in a solar module. The setup is built around a Goldeye CL-033 high-speed SWIR camera, which can acquire...... experimental work on a (36/72) cell solar module using combined (EL) or (IRT) lock-in-thermography. The setup allows one to investigate the different technological problems that can occur when performing PV diagnostics in drone-based inspections....

  13. Nondestructive diagnosis of rotation components of a railway vehicle using infrared thermography and pattern recognitions

    International Nuclear Information System (INIS)

    Kwon, Seok Jin; Kim, Min Su; Seo, Jung Won; Kang, Bu Beong

    2016-01-01

    The faults in railway vehicle components may result in either the stoppage of the service and the derailment of the vehicle. Therefore, it is important to diagnose and monitor the main components of a railway vehicle. The use of temperature is one of the basic methods for the diagnosis of abnormal conditions in the rotational components of a railway vehicle, such as bearings, reduction gears, brake discs, wheels and traction motors. In the present study, the diagnose of the rotational components using infrared thermography and a pattern recognition technique was carried out and a field test was performed. The results show that this method of diagnosis using infrared thermography can be used to identify abnormal conditions in rotational components of a railway vehicle

  14. Nondestructive diagnosis of rotation components of a railway vehicle using infrared thermography and pattern recognitions

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Seok Jin; Kim, Min Su; Seo, Jung Won [New Transportation Research Center, Korea Railroad Research Institute, Uiwang (Korea, Republic of); Kang, Bu Beong [Dept. of of Railway Vehicle System Engineering, Woosong University, Daejeon (Korea, Republic of)

    2016-08-15

    The faults in railway vehicle components may result in either the stoppage of the service and the derailment of the vehicle. Therefore, it is important to diagnose and monitor the main components of a railway vehicle. The use of temperature is one of the basic methods for the diagnosis of abnormal conditions in the rotational components of a railway vehicle, such as bearings, reduction gears, brake discs, wheels and traction motors. In the present study, the diagnose of the rotational components using infrared thermography and a pattern recognition technique was carried out and a field test was performed. The results show that this method of diagnosis using infrared thermography can be used to identify abnormal conditions in rotational components of a railway vehicle.

  15. Panorama Image Processing for Condition Monitoring with Thermography in Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Byoung Joon; Kim, Tae Hwan; Kim, Soon Geol; Mo, Yoon Syub [UNETWARE, Seoul (Korea, Republic of); Kim, Won Tae [Kongju National University, Gongju (Korea, Republic of)

    2010-04-15

    In this paper, imaging processing study obtained from CCD image and thermography image was performed in order to treat easily thermographic data without any risks of personnel who conduct the condition monitoring for the abnormal or failure status occurrable in industrial power plants. This imaging processing is also applicable to the predictive maintenance. For confirming the broad monitoring, a methodology producting single image from the panorama technique was developed no matter how many cameras are employed, including fusion method for discrete configuration for the target. As results, image fusion from quick realtime processing was obtained and it was possible to save time to track the location monitoring in matching the images between CCTV and thermography

  16. Panorama Image Processing for Condition Monitoring with Thermography in Power Plant

    International Nuclear Information System (INIS)

    Jeon, Byoung Joon; Kim, Tae Hwan; Kim, Soon Geol; Mo, Yoon Syub; Kim, Won Tae

    2010-01-01

    In this paper, imaging processing study obtained from CCD image and thermography image was performed in order to treat easily thermographic data without any risks of personnel who conduct the condition monitoring for the abnormal or failure status occurrable in industrial power plants. This imaging processing is also applicable to the predictive maintenance. For confirming the broad monitoring, a methodology producting single image from the panorama technique was developed no matter how many cameras are employed, including fusion method for discrete configuration for the target. As results, image fusion from quick realtime processing was obtained and it was possible to save time to track the location monitoring in matching the images between CCTV and thermography

  17. Visualizing and measuring the temperature field produced by medical diagnostic ultrasound using thermography

    International Nuclear Information System (INIS)

    Vachutka, J; Grec, P; Mornstein, V; Caruana, C J

    2008-01-01

    The heating of tissues by diagnostic ultrasound can pose a significant hazard particularly in the imaging of the unborn child. The demonstration of the temperature field in tissue is therefore an important objective in the teaching of biomedical physics to healthcare professionals. The temperature field in a soft tissue model was made visible and measured using thermography. Temperature data from the images were used to investigate the dependence of temperature increase within the model on ultrasound exposure time and distance from the transducer. The experiment will be used within a multi-professional biomedical physics teaching laboratory for enhancing learning regarding the principles of thermography and the thermal effects of ultrasound to medical and healthcare students and also for demonstrating the quantitative use of thermographic imaging to students of biophysics, medical physics and medical technology

  18. Use of a remote infrared thermography in experimental medicine at extreme influences

    Directory of Open Access Journals (Sweden)

    Datsenko A.V.

    2016-12-01

    Full Text Available The study presents an analysis of published data on the use of remote infrared thermography in medicine and veterinary science and evaluated the main opportunities, methods and ways of thermovision registration in experimental medical studies on biological objects, including at extreme influences. The following resources of the bibliographic electronic databases had been used: eLibrary, PubMed, Clinical Key, Science. Now methods of infrared thermography in insufficient degree are used in experimental medicine, including when studying adverse biological effect of various harmful and dangerous extreme factors, which main manifestation, especially in the early period after exposure, are systemic microvascular disorders, determining the state of capacity of human biomodels. These dynamic remote ther-mographic studies of experimental biological objects can be used to evaluate disorders of the peripheral circulation, working capacity and an emotional condition of the biomodels exposed to extreme factors, including early after experimental studies in laboratory and field work.

  19. Investigation of the energy efficiency of the military museum building by infrared thermography

    Directory of Open Access Journals (Sweden)

    Slavica S. Ristić

    2013-06-01

    Full Text Available Infrared (IR thermography, as a diagnostic technique, is used to find anomalies in the thermal signature of the Military museum building in Belgrade, to identify irregularities or deficiencies, such as wet materials, voids, or missing insulation and to inspect energy efficiency of the museum building and microclimatic indoor conditions.  It is very important to perform preventative maintenance and stop undesirable environment influences that induce structural damage, modification of materials and agglomeration of pollutants and microorganisms on the cultural heritage artifacts, stored in the museum depot or exhibited in the galleries. The main causes for corrosion in historical buildings and museum artifacts are moisture and changeable temperature conditions. This paper deals with the results obtained in the application of IR thermography in determination of these conditions in the Military museum building, where very important metal artifacts are exhibited and deposed. The results show poor thermal insulation, wet walls and, generally, low energy efficiency.

  20. Detection and characterization of exercise induced muscle damage (EIMD) via thermography and image processing

    DEFF Research Database (Denmark)

    Avdelidis, Nicolas; Kappatos, Vassilios; Georgoulas, George

    2017-01-01

    of commonly measurement tools and methods. Thermography has been used successfully as a research detection tool in medicine for the last 6 decades but very limited work has been reported on EIMD area. The main purpose of this research is to assess and characterize EIMD, using thermography and image processing...... techniques. The first step towards that goal is to develop a reliable segmentation technique to isolate the region of interest (ROI). A semi-automatic image processing software was designed and regions of the left and right leg based on superpixels were segmented. The image is segmented into a number...... of regions and the user is able to intervene providing the regions which belong to each of the two legs. In order to validate the image processing software, an extensive experimental investigation was carried out, acquiring thermographic images of the rectus femoris muscle before, immediately post and 24, 48...

  1. Motion-induced eddy current thermography for high-speed inspection

    Directory of Open Access Journals (Sweden)

    Jianbo Wu

    2017-08-01

    Full Text Available This letter proposes a novel motion-induced eddy current based thermography (MIECT for high-speed inspection. In contrast to conventional eddy current thermography (ECT based on a time-varying magnetic field created by an AC coil, the motion-induced eddy current is induced by the relative motion between magnetic field and inspected objects. A rotating magnetic field created by three-phase windings is used to investigate the heating principle and feasibility of the proposed method. Firstly, based on Faraday’s law the distribution of MIEC is investigated, which is then validated by numerical simulation. Further, experimental studies are conducted to validate the proposed method by creating rotating magnetic fields at different speeds from 600 rpm to 6000 rpm, and it is verified that rotating speed will increase MIEC intensity and thereafter improve the heating efficiency. The conclusion can be preliminarily drawn that the proposed MIECT is a platform suitable for high-speed inspection.

  2. Quantitative defects detection in wind turbine blade using optical infrared thermography

    Energy Technology Data Exchange (ETDEWEB)

    Kwaon, Koo Ahn [School of Aerospace System Engineering, UST, Daejeon (Korea, Republic of); Choi, Man Yong; Park, Hee Sang; Park, Jeong Hak; Huh, Yong Hak; Choi, Won Jai [Safety Measurement Center, Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of)

    2015-02-15

    A wind turbine blade is an important component in wind-power generation, and is generally exposed to harsh environmental conditions. Ultrasonic inspection is mainly used to inspect such blades, but it has been difficult to quantify defect sizes in complicated composite structures. Recently, active infrared thermography has been widely studied for inspecting composite structures, in which thermal energy is applied to an object, and an infrared camera detects the energy emitted from it. In this paper, a calibration method for active optical lock-in thermography is proposed to quantify the size. Inclusion, debonding and wrinkle defects, created in a wind blade for 100 kW wind power generation, were all successfully detected using this method. In particular, a 50.0 mm debonding defect was sized with 98.0% accuracy.

  3. Coupling IR Thermography and BIA to analyse body reaction after one acupuncture session

    International Nuclear Information System (INIS)

    Piquemal, M

    2013-01-01

    Coupling both thermography and bio-Impedance, some biophysical acupuncture mechanisms are statically studied on a small population of 18 subjects. Results show that a possible way of understanding acupuncture, in an electrical way, should be to consider ionic flux redistribution between vascular and extra cell compartments. This is a two steps mechanism. The first one is starting with needles insertion and the second one is lasting with more intensity after removing them from skin.

  4. Ultrasound Burst Phase Thermography (UBP) for applications in the automotive industry

    International Nuclear Information System (INIS)

    Zweschper, T.; Riegert, G.; Dillenz, A.; Busse, G.

    2003-01-01

    The use of elastic waves in combination with thermal waves allows to separate structural information about investigated components from defect specific thermal signatures. Ultrasound Burst Phase thermography (UBP) is an defect-selective and fast imaging tool for damage detection. This contribution presents results obtained on various kinds of problems related to modern automobile production (crack detection in grey cast iron and aluminum, characterization of adhesive-bonded joints etc.). Advances resulting from frequency modulated ultrasound excitation will be presented

  5. Energy flux to the ASDEX-upgrade diverter plates determined by thermography and calorimetry

    International Nuclear Information System (INIS)

    Herrmann, A.; Junker, W.; Guenther, K.

    1995-01-01

    A new thermography system with high time resolution was put into operation at ASDEX-Upgrade and is routinely used to determine the energy flux onto the lower diverter plates. The measurements allow the power deposition to be characterized during dynamic events such as ELMs and disruptions, as well as the asymmetry of the inboard/outboard power load. A power balance is set up even during single discharges and the losses are found to be fairly equal to the power input. (author)

  6. Methodology for heat flux investigation on leading edges using infrared thermography

    Czech Academy of Sciences Publication Activity Database

    Corre, Y.; Gardarein, J.-L.; Dejarnac, Renaud; Gaspar, J.; Gunn, J. P.; Aumeunier, M.-H.; Courtois, X.; Missirlian, M.; Rigollet, F.

    2017-01-01

    Roč. 57, č. 1 (2017), č. článku 016009. ISSN 0029-5515 Institutional support: RVO:61389021 Keywords : IR thermography * leading edge * heat flux * limiter Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: Fluids and plasma physics (including surface physics) Impact factor: 3.307, year: 2016 http://iopscience.iop.org/article/10.1088/0029-5515/57/1/016009/meta

  7. Coupling IR Thermography and BIA to analyse body reaction after one acupuncture session

    Science.gov (United States)

    Piquemal, M.

    2013-04-01

    Coupling both thermography and bio-Impedance, some biophysical acupuncture mechanisms are statically studied on a small population of 18 subjects. Results show that a possible way of understanding acupuncture, in an electrical way, should be to consider ionic flux redistribution between vascular and extra cell compartments. This is a two steps mechanism. The first one is starting with needles insertion and the second one is lasting with more intensity after removing them from skin.

  8. Detection of defects in multi-layered aramid composites by ultrasonic IR thermography

    Science.gov (United States)

    Pracht, Monika; Swiderski, Waldemar

    2017-10-01

    In military applications, laminates reinforced with aramid, carbon, and glass fibers are used for the construction of protection products against light ballistics. Material layers can be very different by their physical properties. Therefore, such materials represent a difficult inspection task for many traditional techniques of non-destructive testing (NDT). Defects which can appear in this type of many-layered composite materials usually are inaccuracies in gluing composite layers and stratifications or delaminations occurring under hits of fragments and bullets. IR thermographic NDT is considered as a candidate technique to detect such defects. One of the active IR thermography methods used in nondestructive testing is vibrothermography. The term vibrothermography was created in the 1990s to determine the thermal test procedures designed to assess the hidden heterogeneity of structural materials based on surface temperature fields at cyclical mechanical loads. A similar procedure can be done with sound and ultrasonic stimulation of the material, because the cause of an increase in temperature is internal friction between the wall defect and the stimulation mechanical waves. If the cyclic loading does not exceed the flexibility of the material and the rate of change is not large, the heat loss due to thermal conductivity is small, and the test object returns to its original shape and temperature. The most commonly used method is ultrasonic stimulation, and the testing technique is ultrasonic infrared thermography. Ultrasonic IR thermography is based on two basic phenomena. First, the elastic properties of defects differ from the surroundings, and acoustic damping and heating are always larger in the damaged regions than in the undamaged or homogeneous areas. Second, the heat transfer in the sample is dependent on its thermal properties. In this paper, both modelling and experimental results which illustrate the advantages and limitations of ultrasonic IR

  9. Application of thermography to assess the adequacy training in elite athletes

    International Nuclear Information System (INIS)

    Jover, A.; Salvador, R.; Cibrian, R.; Gonzalez-Pena, R.; Minguez, M. F.; Pino, L.; Lopez de la O, F. J.; Guillen, J.; Reinado, D.; Cortina, T.; Chinillach, N.; Dalmases, F.; Romero, C.; Martinez-Celorio, R.; Diez, S.; Rosello, J.; Reinado, D.; Cortina, T.; Chinillach, N.; Dalmases, F.; Romero, C.; Martinez-Celorio, R.; Diez, S.; Rosello, J.

    2011-01-01

    Thermography is a technique that allows to know the body surface temperature by infrared radiation, making it a completely non-invasive technique, without physical contact. The differences in body temperature in different parts of the body naturally shown in the thermo gram and given that sport can alter the temperature distribution is imaging technique can help to analyze the effect of training on muscle and determine if it has been appropriate and correct.

  10. On the use of infrared thermography in studies with air curtain devices

    OpenAIRE

    Neto, Luís P. C.; Silva, Manuel Gameiro da; Costa, José J.

    2006-01-01

    Among the different existing methods to characterise the aerodynamic sealing effect provided by an air curtain device placed over the opening between two contiguous compartments, infrared thermography has revealed to be a very useful tool. Besides allowing the capture, in an expedite way, of instantaneous images of the temperature field in the neighbourhood of the door, the technique hereon described has other advantages, in terms of quick and easy setup, low intrusive character and liability ...

  11. Liquid crystal thermography of the testicles in the diagnosis of infertility

    Energy Technology Data Exchange (ETDEWEB)

    Goeblyoes, P.; Vydra, G.; Szabolcs, I.; Irsy, G.; Goth, M.; Szilagyi, G.

    1982-08-01

    The use of liquid thermography (LCT) of the testicles in diagnosis of infertility was investigated. Varicocele, the most common cause of male infertility, is easily detectable by LCT. The technique may be used as a control after surgical treatment. In the majority of patients with oligo-azoospermia, LCT corresponded to physical examination of the testicles. In patients with oligo-azoospermia and both testicles normal to palpation, LCT is useful method for determining the colder testicle for biopsy purposes.

  12. Liquid crystal thermography of the testicles in the diagnosis of infertility

    International Nuclear Information System (INIS)

    Goeblyoes, P.; Vydra, G.; Szabolcs, I.; Irsy, G.; Goth, M.; Szilagyi, G.

    1982-01-01

    The use of liquid thermography (LCT) of the testicles in diagnosis of infertility was investigated. Varicocele, the most common cause of male infertility, is easily detectable by LCT. The technique may be used as a control after surgical treatment. In the majority of patients with oligo-azoospermia, LCT corresponded to physical examination of the testicles. In patients with oligo-azoospermia and both testicles normal to palpation, LCT is useful method for determining the colder testicle for biopsy purposes. (orig.)

  13. Breast Tomosynthesis

    Science.gov (United States)

    ... in distinguishing non-cancerous breast conditions from breast cancers. Breast implants may also impede accurate mammogram readings because both ... view as much as possible without rupturing the implant. top of ... discuss breast cancer screening options with their doctors: Breast Density and ...

  14. Laser lock-in thermography for thermal contact characterisation of surface layer

    International Nuclear Information System (INIS)

    Semerok, A.; Jaubert, F.; Fomichev, S.V.; Thro, P.-Y.; Courtois, X.; Grisolia, C.

    2012-01-01

    Lock-in thermography was applied to determine the thermal contact conductance of a W-layer (140 μm) on a CFC-substrate. A lock-in thermography system together with a pulse repetition rate Nd:YAG laser (1064 nm, 1–500 Hz pulse repetition rate) for layer heating was applied for phase shift measurements on the W-layer. A numerical model for direct phase shift calculations was developed and applied to rapid determination of the Fourier amplitudes and phases of the temperature. Thermal conductance coefficients were obtained by comparing the experimental and simulation phase shifts. -- Highlights: ► Lock-in thermography determines a layer/substrate thermal conductance. ► Thermal conductance coefficient of W-layer on a CFC-substrate. ► Model for direct phase shift calculations was developed and applied. ► Rapid determination of the Fourier amplitudes and phases of the temperature. ► Comparing the experimental and simulation phase shifts.

  15. Simulation of surface cracks measurement in first walls by laser spot array thermography

    Energy Technology Data Exchange (ETDEWEB)

    Pei, Cuixiang; Qiu, Jinxin; Liu, Haocheng; Chen, Zhenmao, E-mail: chenzm@mail.xjtu.edu.cn

    2016-11-01

    The inspection of surface cracks in first walls (FW) is very important to ensure the safe operation of the fusion reactors. In this paper, a new laser excited thermography technique with using laser spot array source is proposed for the surface cracks imaging and evaluation in the FW with an intuitive and non-contact measurement method. Instead of imaging a crack by scanning a single laser spot and superimposing the local discontinuity images with the present laser excited thermography methods, it can inspect a relatively large area at one measurement. It does not only simplify the measurement system and data processing procedure, but also provide a faster measurement for FW. In order to investigate the feasibility of this method, a numerical code based on finite element method (FEM) is developed to simulate the heat flow and the effect of the crack geometry on the thermal wave fields. An imaging method based on the gradient of the thermal images is proposed for crack measurement with the laser spot array thermography method.

  16. Diagnosis of X-Linked Hypohidrotic Ectodermal Dysplasia by Meibography and Infrared Thermography of the Eye.

    Science.gov (United States)

    Kaercher, Thomas; Dietz, Jasna; Jacobi, Christina; Berz, Reinhold; Schneider, Holm

    2015-09-01

    X-linked hypohidrotic ectodermal dysplasia (XLHED) is the most common form of ectodermal dysplasia. Clinical characteristics include meibomian gland disorder and the resulting hyperevaporative dry eye. In this study, we evaluated meibography and ocular infrared thermography as novel methods to diagnose XLHED. Eight infants, 12 boys and 14 male adults with XLHED and 12 healthy control subjects were subjected to a panel of tests including the ocular surface disease index (OSDI), meibography and infrared thermography, non-invasive measurement of tear film break-up time (NIBUT) and osmolarity, Schirmer's test, lissamine green staining and fluorescein staining. Sensitivity and specificity were determined for single tests and selected test combinations. Meibography had 100% sensitivity and specificity for identifying XLHED. Infrared thermography, a completely non-invasive procedure, revealed a typical pattern for male subjects with XLHED. It was, however, less sensitive (86% for adults and 67% for children) than meibography or a combination of established routine tests. In adults, OSDI and NIBUT were the best single routine tests (sensitivity of 86% and 71%, respectively), whereas increased tear osmolarity appeared as a rather unspecific ophthalmic symptom. In children, NIBUT was the most convincing routine test (sensitivity of 91%). Meibography is the most reliable ophthalmic examination to establish a clinical diagnosis in individuals with suspected hypohidrotic ectodermal dysplasia, even before genetic test results are available. Tear film tests and ocular surface staining are less sensitive in children, but very helpful for estimating the severity of ocular surface disease in individuals with known XLHED.

  17. Infrared thermography based on artificial intelligence for carpal tunnel syndrome diagnosis.

    Science.gov (United States)

    Jesensek Papez, B; Palfy, M; Turk, Z

    2008-01-01

    Thermography for the measurement of surface temperatures is well known in industry, although is not established in medicine despite its safety, lack of pain and invasiveness, easy reproducibility, and low running costs. Promising results have been achieved in nerve entrapment syndromes, although thermography has never represented a real alternative to electromyography. Here an attempt is described to improve the diagnosis of carpal tunnel syndrome with thermography using a computer-based system employing artificial neural networks to analyse the images. Method reliability was tested on 112 images (depicting the dorsal and palmar sides of 26 healthy and 30 pathological hands), with the hand divided into 12 segments and compared relative to a reference. Palmar segments appeared to have no beneficial influence on classification outcome, whereas dorsal segments gave improved outcome with classification success rates near to or over 80%, and finger segments influenced by the median nerve appeared to be of greatest importance. These are preliminary results from a limited number of images and further research will be undertaken as our image database grows.

  18. A numerical study on the influence of vulnerable plaque composition on intravascular thermography measurements

    International Nuclear Information System (INIS)

    Have, A G ten; Gijsen, F J H; Wentzel, J J; Slager, C J; Serruys, P W; Steen, A F W van der

    2006-01-01

    Intracoronary thermography is a technique that measures lumen wall temperatures for vulnerable plaque detection. In this paper the influence of vulnerable plaque composition on lumen wall temperatures was studied numerically. Concerning the vulnerable plaque heat generation, the location of the heat source and its heat production were varied. Concerning the heat transfer, the thermal properties of the lipid core and the location of the vasa vasorum were studied. The heat source location was the main determinant of the lumen wall temperature distribution. The strongest effect was noted when the heat producing macrophages were located in the shoulder region leading to focal spots of higher temperature. The maximal lumen wall temperature was mainly determined by the heat production of the macrophages and the cooling effect of blood. The insulating properties of the lipid core increased lumen wall temperatures when the heat source was located in the cap and the presence of vasa vasorum lowered the temperatures. These results show that the lumen wall temperature distribution is influenced by vulnerable plaque composition and that intracoronary thermography techniques require a high spatial resolution. To be able to couple temperature measurements to plaque vulnerability, intracoronary thermography needs to be combined with an imaging modality

  19. Active Infrared Thermography for Seal Contamination Detection in Heat-Sealed Food Packaging

    Directory of Open Access Journals (Sweden)

    Karlien D’huys

    2016-11-01

    Full Text Available Packaging protects food products from environmental influences, assuring quality and safety throughout shelf life if properly performed. Packaging quality depends on the quality of the packaging material and of the closure or seal. A common problem possibly jeopardizing seal quality is the presence of seal contamination, which can cause a decreased seal strength, an increased packaging failure risk and leak formation. Therefore, early detection and removal of seal contaminated packages from the production chain is crucial. In this work, a pulsed-type active thermography method using the heated seal bars as an excitation source was studied for detecting seal contamination. Thermal image sequences of contaminated seals were recorded shortly after sealing. The detection performances of six thermal image processing methods, based on a single frame, a fit of the cooling profiles, thermal signal reconstruction, pulsed phase thermography, principal component thermography and a matched filter, were compared. High resolution digital images served as a reference to quantify seal contamination, and processed thermal images were mapped to these references. The lowest detection limit (equivalent diameter 0.60 mm was obtained for the method based on a fit of the cooling profiles. Moreover, the detection performance of this method did not depend strongly on the time after sealing at which recording of the thermal images was started, making it a robust and generally applicable method.

  20. Non-Destructive Thermography Analysis of Impact Damage on Large-Scale CFRP Automotive Parts

    Science.gov (United States)

    Maier, Alexander; Schmidt, Roland; Oswald-Tranta, Beate; Schledjewski, Ralf

    2014-01-01

    Laminated composites are increasingly used in aeronautics and the wind energy industry, as well as in the automotive industry. In these applications, the construction and processing need to fulfill the highest requirements regarding weight and mechanical properties. Environmental issues, like fuel consumption and CO2-footprint, set new challenges in producing lightweight parts that meet the highly monitored standards for these branches. In the automotive industry, one main aspect of construction is the impact behavior of structural parts. To verify the quality of parts made from composite materials with little effort, cost and time, non-destructive test methods are increasingly used. A highly recommended non-destructive testing method is thermography analysis. In this work, a prototype for a car’s base plate was produced by using vacuum infusion. For research work, testing specimens were produced with the same multi-layer build up as the prototypes. These specimens were charged with defined loads in impact tests to simulate the effect of stone chips. Afterwards, the impacted specimens were investigated with thermography analysis. The research results in that work will help to understand the possible fields of application and the usage of thermography analysis as the first quick and economic failure detection method for automotive parts. PMID:28788464

  1. Quantification of defects depth in glass fiber reinforced plastic plate by infrared lock-in thermography

    Energy Technology Data Exchange (ETDEWEB)

    Ranjit, Shrestha; Kim, Won Tae [Kongju National University, Cheonan (Korea, Republic of); Choi, Man Yong [Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of)

    2016-03-15

    The increasing use of composite materials in various industries has evidenced the need for development of more effective nondestructive evaluation methodologies in order to reduce rejected parts and to optimize production cost. Infrared thermography is a noncontact, fast and reliable non-destructive evaluation technique that has received vast and growing attention for diagnostic and monitoring in the recent years. This paper describes the quantitative analysis of artificial defects in Glass fiber reinforced plastic plate by using Lockin infrared thermography. The experimental analysis was performed at several excitation frequencies to investigate the sample ranging from 2.946 Hz down to 0.019 Hz and the effects of each excitation frequency on defect detachability. The four point method was used in post processing of every pixel of thermal images using the MATLAB programming language. The relationship between the phase contrast with defects depth and area was examined. Finally, phase contrast method was used to calculate the defects depth considering the thermal diffusivity of the material being inspected and the excitation frequency for which the defect becomes visible. The obtained results demonstrated the effectiveness of Lock-in infrared thermography as a powerful measurement technique for the inspection of Glass fiber reinforced plastic structures.

  2. Non-Destructive Thermography Analysis of Impact Damage on Large-Scale CFRP Automotive Parts

    Directory of Open Access Journals (Sweden)

    Alexander Maier

    2014-01-01

    Full Text Available Laminated composites are increasingly used in aeronautics and the wind energy industry, as well as in the automotive industry. In these applications, the construction and processing need to fulfill the highest requirements regarding weight and mechanical properties. Environmental issues, like fuel consumption and CO2-footprint, set new challenges in producing lightweight parts that meet the highly monitored standards for these branches. In the automotive industry, one main aspect of construction is the impact behavior of structural parts. To verify the quality of parts made from composite materials with little effort, cost and time, non-destructive test methods are increasingly used. A highly recommended non-destructive testing method is thermography analysis. In this work, a prototype for a car’s base plate was produced by using vacuum infusion. For research work, testing specimens were produced with the same multi-layer build up as the prototypes. These specimens were charged with defined loads in impact tests to simulate the effect of stone chips. Afterwards, the impacted specimens were investigated with thermography analysis. The research results in that work will help to understand the possible fields of application and the usage of thermography analysis as the first quick and economic failure detection method for automotive parts.

  3. Detection and location of fouling on photovoltaic panels using a drone-mounted infrared thermography system

    Science.gov (United States)

    Zhang, Peng; Zhang, Lifu; Wu, Taixia; Zhang, Hongming; Sun, Xuejian

    2017-01-01

    Due to weathering and external forces, solar panels are subject to fouling and defects after a certain amount of time in service. These fouling and defects have direct adverse consequences such as low-power efficiency. Because solar power plants usually have large-scale photovoltaic (PV) panels, fast detection and location of fouling and defects across large PV areas are imperative. A drone-mounted infrared thermography system was designed and developed, and its ability to detect rapid fouling on large-scale PV panel systems was investigated. The infrared images were preprocessed using the K neighbor mean filter, and the single PV module on each image was recognized and extracted. Combining the local and global detection method, suspicious sites were located precisely. The results showed the flexible drone-mounted infrared thermography system to have a strong ability to detect the presence and determine the position of PV fouling. Drone-mounted infrared thermography also has good technical feasibility and practical value in the detection of PV fouling detection.

  4. Detection and assessment of electrocution in endangered raptors by infrared thermography.

    Science.gov (United States)

    Melero, Mar; González, Fernando; Nicolás, Olga; López, Irene; Jiménez, María de Los Ángeles; Jato-Sánchez, Susana; Sánchez-Vizcaíno, José Manuel

    2013-07-23

    Most European birds of prey find themselves in a poor state of conservation, with electrocution as one of the most frequent causes of unnatural death. Since early detection of electrocution is difficult, treatment is usually implemented late, which reduces its effectiveness. By considering that electrocution reduces tissue temperature, it may be detectable by thermography, which would allow a more rapid identification. Three individuals from three endangered raptor species [Spanish imperial eagle (Aquila adalberti), Lammergeier (Gypaetus barbatus) and Osprey (Pandion haliaetus)] were studied thermographically from the time they were admitted to a rehabilitation centre to the time their clinical cases were resolved. The three raptors presented lesions lacking thermal bilateral symmetry and were consistent with electrocution of feet, wings and eyes, visible by thermography before than clinically; lesions were well-defined and showed a lower temperature than the surrounding tissue. Some lesions evolved thermally and clinically until the appearance of normal tissue recovered, while others evolved and became necrotic. A histopathological analysis of a damaged finger amputated off a Lammergeier, and the necropsy and histopathology examination of an osprey, confirmed the electrocution diagnosis. These results suggest that thermography is effective and useful for the objective and early detection and monitoring of electrocuted birds, and that it may prove especially useful for examining live animals that require no amputation or cannot be subjected to invasive histopathology.

  5. Enhancing the Accuracy of Advanced High Temperature Mechanical Testing through Thermography

    Directory of Open Access Journals (Sweden)

    Jonathan Jones

    2018-03-01

    Full Text Available This paper describes the advantages and enhanced accuracy thermography provides to high temperature mechanical testing. This technique is not only used to monitor, but also to control test specimen temperatures where the infra-red technique enables accurate non-invasive control of rapid thermal cycling for non-metallic materials. Isothermal and dynamic waveforms are employed over a 200–800 °C temperature range to pre-oxidised and coated specimens to assess the capability of the technique. This application shows thermography to be accurate to within ±2 °C of thermocouples, a standardised measurement technique. This work demonstrates the superior visibility of test temperatures previously unobtainable by conventional thermocouples or even more modern pyrometers that thermography can deliver. As a result, the speed and accuracy of thermal profiling, thermal gradient measurements and cold/hot spot identification using the technique has increased significantly to the point where temperature can now be controlled by averaging over a specified area. The increased visibility of specimen temperatures has revealed additional unknown effects such as thermocouple shadowing, preferential crack tip heating within an induction coil, and, fundamental response time of individual measurement techniques which are investigated further.

  6. Detection of seal contamination in heat-sealed food packaging based on active infrared thermography

    Science.gov (United States)

    D'huys, Karlien; Saeys, Wouter; De Ketelaere, Bart

    2015-05-01

    In the food industry packaging is often applied to protect the product from the environment, assuring quality and safety throughout shelf life if properly performed. Packaging quality depends on the material used and the closure (seal). The material is selected based on the specific needs of the food product to be wrapped. However, proper closure of the package is often harder to achieve. One problem possibly jeopardizing seal quality is the presence of food particles between the seal. Seal contamination can cause a decreased seal strength and thus an increased packaging failure risk. It can also trigger the formation of microchannels through which air and microorganisms can enter and spoil the enclosed food. Therefore, early detection and removal of seal-contaminated packages from the production chain is essential. In this work, a pulsed-type active thermography method using the heat of the sealing bars as an excitation source was studied for detecting seal contamination. The cooling profile of contaminated seals was recorded. The detection performance of four processing methods (based on a single frame, a fit of the cooling profile, pulsed phase thermography and a matched filter) was compared. High resolution digital images served as a reference to quantify contamination. The lowest detection limit (equivalent diameter of 0.63 mm) and the lowest processing time (0.42 s per sample) were obtained for the method based on a single frame. Presumably, practical limitations in the recording stage prevented the added value of active thermography to be fully reflected in this application.

  7. Non-Destructive Thermography Analysis of Impact Damage on Large-Scale CFRP Automotive Parts.

    Science.gov (United States)

    Maier, Alexander; Schmidt, Roland; Oswald-Tranta, Beate; Schledjewski, Ralf

    2014-01-14

    Laminated composites are increasingly used in aeronautics and the wind energy industry, as well as in the automotive industry. In these applications, the construction and processing need to fulfill the highest requirements regarding weight and mechanical properties. Environmental issues, like fuel consumption and CO₂-footprint, set new challenges in producing lightweight parts that meet the highly monitored standards for these branches. In the automotive industry, one main aspect of construction is the impact behavior of structural parts. To verify the quality of parts made from composite materials with little effort, cost and time, non-destructive test methods are increasingly used. A highly recommended non-destructive testing method is thermography analysis. In this work, a prototype for a car's base plate was produced by using vacuum infusion. For research work, testing specimens were produced with the same multi-layer build up as the prototypes. These specimens were charged with defined loads in impact tests to simulate the effect of stone chips. Afterwards, the impacted specimens were investigated with thermography analysis. The research results in that work will help to understand the possible fields of application and the usage of thermography analysis as the first quick and economic failure detection method for automotive parts.

  8. Application of Infrared Thermography as a Diagnostic Tool of Knee Osteoarthritis

    Science.gov (United States)

    Arfaoui, Ahlem; Bouzid, Mohamed Amine; Pron, Hervé; Taiar, Redha; Polidori, Guillaume

    This paper aimed to study the feasibility of application of infrared thermography to detect osteoarthritis of the knee and to compare the distribution of skin temperature between participants with osteoarthritis and those without pathology. All tests were conducted at LACM (Laboratory of Mechanical Stresses Analysis) and the gymnasium of the University of Reims Champagne Ardennes. IR thermography was performed using an IR camera. Ten participants with knee osteoarthritis and 12 reference healthy participants without OA participated in this study. Questionnaires were also used. The participants with osteoarthritis of the knee were selected on clinical examination and a series of radiographs. The level of pain was recorded by using a simple verbal scale (0-4). Infrared thermography reveals relevant disease by highlighting asymmetrical behavior in thermal color maps of both knees. Moreover, a linear evolution of skin temperature in the knee area versus time has been found whatever the participant group is in the first stage following a given effort. Results clearly show that the temperature can be regarded as a key parameter for evaluating pain. Thermal images of the knee were taken with an infrared camera. The study shows that with the advantage of being noninvasive and easily repeatable, IRT appears to be a useful tool to detect quantifiable patterns of surface temperatures and predict the singular thermal behavior of this pathology. It also seems that this non-intrusive technique enables to detect the early clinical manifestations of knee OA.

  9. Analysis of breast thermograms using Gabor wavelet anisotropy index.

    Science.gov (United States)

    Suganthi, S S; Ramakrishnan, S

    2014-09-01

    In this study, an attempt is made to distinguish the normal and abnormal tissues in breast thermal images using Gabor wavelet transform. Thermograms having normal, benign and malignant tissues are considered in this study and are obtained from public online database. Segmentation of breast tissues is performed by multiplying raw image and ground truth mask. Left and right breast regions are separated after removing the non-breast regions from the segmented image. Based on the pathological conditions, the separated breast regions are grouped as normal and abnormal tissues. Gabor features such as energy and amplitude in different scales and orientations are extracted. Anisotropy and orientation measures are calculated from the extracted features and analyzed. A distinctive variation is observed among different orientations of the extracted features. It is found that the anisotropy measure is capable of differentiating the structural changes due to varied metabolic conditions. Further, the Gabor features also showed relative variations among different pathological conditions. It appears that these features can be used efficiently to identify normal and abnormal tissues and hence, improve the relevance of breast thermography in early detection of breast cancer and content based image retrieval.

  10. Extended investigation of the twelve-flavor β-function

    Science.gov (United States)

    Fodor, Zoltán; Holland, Kieran; Kuti, Julius; Nógrádi, Dániel; Wong, Chik Him

    2018-04-01

    We report new results from high precision analysis of an important BSM gauge theory with twelve massless fermion flavors in the fundamental representation of the SU(3) color gauge group. The range of the renormalized gauge coupling is extended from our earlier work [1] to probe the existence of an infrared fixed point (IRFP) in the β-function reported at two different locations, originally in [2] and at a new location in [3]. We find no evidence for the IRFP of the β-function in the extended range of the renormalized gauge coupling, in disagreement with [2,3]. New arguments to guard the existence of the IRFP remain unconvincing [4], including recent claims of an IRFP with ten massless fermion flavors [5,6] which we also rule out. Predictions of the recently completed 5-loop QCD β-function for general flavor number are discussed in this context.

  11. Twelve reasons to refuse the nuclear in the MDP

    International Nuclear Information System (INIS)

    Bonduelle, A.

    2000-01-01

    The author presents twelve reasons which show that the nuclear energy has not a place in the MDP Mechanism of Clean Development: a main loophole for the developed countries, the doubtful ''additionality'' of the nuclear, the treaty ratification is more difficult with the nuclear, the domestic energy conservation is more efficient in Europe than the nuclear development, the nuclear white elephants facing the South debts, the technology transfers are doubtful, the developing countries and the sustainable development policies are evicted from the MDP, some options are more powerful in the South, the reactors and transport networks size are unsuited, the absence of democratic control, the nuclear proliferation, the nuclear safety and the wastes. (A.L.B.)

  12. Breast infection

    Science.gov (United States)

    Mastitis; Infection - breast tissue; Breast abscess ... must continue to breastfeed or pump to relieve breast swelling from milk production. In case if the abscess does not go away, needle aspiration under ultrasound ...

  13. Breast lump

    Science.gov (United States)

    ... with milk). These cysts can occur with breastfeeding. Breast abscess . These typically occur if you are breastfeeding or ... Breast infections are treated with antibiotics. Sometimes a breast abscess needs to be drained with a needle or ...

  14. Breast Diseases

    Science.gov (United States)

    ... bumps, and discharges (fluids that are not breast milk). If you have a breast lump, pain, discharge or skin irritation, see your health care provider. Minor and serious breast problems have similar ...

  15. Breast lift

    Science.gov (United States)

    ... and areola may be moved. Sometimes, women have breast augmentation (enlargement with implants) when they have a breast lift. Why the ... MD, FACS, general surgery practice specializing in breast cancer, Virginia Mason Medical Center, Seattle, WA. Also reviewed ...

  16. Breast cancer

    Science.gov (United States)

    ... can help you know how to prevent breast cancer. Breast implants, using antiperspirants, and wearing underwire bras do not increase the risk for breast cancer. There is also no evidence of a direct ...

  17. Fibroadenoma - breast

    Science.gov (United States)

    Breast lump - fibroadenoma; Breast lump - noncancerous; Breast lump - benign ... The cause of fibroadenomas is not known. They may be related to hormones. Girls who are going through puberty and women who are ...

  18. Non Destructive Testing by active infrared thermography coupled with shearography under same optical heat excitation

    Science.gov (United States)

    Theroux, Louis-Daniel; Dumoulin, Jean; Maldague, Xavier

    2014-05-01

    As infrastructures are aging, the evaluation of their health is becoming crucial. To do so, numerous Non Destructive Testing (NDT) methods are available. Among them, thermal shearography and active infrared thermography represent two full field and contactless methods for surface inspection. The synchronized use of both methods presents multiples advantages. Most importantly, both NDT are based on different material properties. Thermography depend on the thermal properties and shearography on the mechanical properties. The cross-correlation of both methods result in a more accurate and exact detection of the defects. For real site application, the simultaneous use of both methods is simplified due to the fact that the excitation method (thermal) is the same. Active infrared thermography is the measure of the temperature by an infrared camera of a surface subjected to heat flux. Observation of the variation of temperature in function of time reveal the presence of defects. On the other hand, shearography is a measure of out-of-plane surface displacement. This displacement is caused by the application of a strain on the surface which (in our case) take the form of a temperature gradient inducing a thermal stress To measure the resulting out-of-plane displacement, shearography exploit the relation between the phase difference and the optical path length. The phase difference is measured by the observation of the interference between two coherent light beam projected on the surface. This interference is due to change in optical path length as the surface is deformed [1]. A series of experimentation have been conducted in laboratory with various sample of concrete reinforced with CFRP materials. Results obtained reveal that with both methods it was possible to detect defects in the gluing. An infrared lamp radiating was used as the active heat source. This is necessary if measurements with shearography are to be made during the heating process. A heating lamp in the

  19. Active and passive infrared thermography applied to the detection and characterization of hidden defects in structure

    Science.gov (United States)

    Dumoulin, Jean

    2013-04-01

    Infrared thermography for Non Destructive Testing (NDT) has encountered a wide spreading this last 2 decades, in particular thanks to emergence on the market of low cost uncooled infrared camera. So, infrared thermography is not anymore a measurement technique limited to laboratory application. It has been more and more involved in civil engineering and cultural heritage applications, but also in many other domains, as indicated by numerous papers in the literature. Nevertheless, laboratory, measurements are done as much as possible in quite ideal conditions (good atmosphere conditions, known properties of materials, etc.), while measurement on real site requires to consider the influence of not controlled environmental parameters and additional unknown thermal properties. So, dedicated protocol and additional sensors are required for measurement data correction. Furthermore, thermal excitation is required to enhance the signature of defects in materials. Post-processing of data requires to take into account the protocol used for the thermal excitation and sometimes its nature to avoid false detection. This analysis step is based on signal and image processing tool and allows to carry out the detection. Characterization of anomalies detected at the previous step can be done by additional signal processing in particular for manufactured objects. The use of thermal modelling and inverse method allows to determine properties of the defective area. The present paper will first address a review of some protocols currently in use for field measurement with passive and/or active infrared measurements. Illustrations in various experiments carried out on civil engineering structure will be shown and discussed. In a second part, different post-processing approaches will be presented and discussed. In particular, a review of the most standard processing methods like Fast Fourier Analysis, Principal Components Analysis, Polynomial Decomposition, defect characterization using

  20. Breast reconstruction - implants

    Science.gov (United States)

    Breast implants surgery; Mastectomy - breast reconstruction with implants; Breast cancer - breast reconstruction with implants ... harder to find a tumor if your breast cancer comes back. Getting breast implants does not take as long as breast reconstruction ...

  1. Short-circuit current density imaging of crystalline silicon solar cells via lock-in thermography: Robustness and simplifications

    International Nuclear Information System (INIS)

    Fertig, Fabian; Greulich, Johannes; Rein, Stefan

    2014-01-01

    Spatially resolved determination of solar cell parameters is beneficial for loss analysis and optimization of conversion efficiency. One key parameter that has been challenging to access by an imaging technique on solar cell level is short-circuit current density. This work discusses the robustness of a recently suggested approach to determine short-circuit current density spatially resolved based on a series of lock-in thermography images and options for a simplified image acquisition procedure. For an accurate result, one or two emissivity-corrected illuminated lock-in thermography images and one dark lock-in thermography image have to be recorded. The dark lock-in thermography image can be omitted if local shunts are negligible. Furthermore, it is shown that omitting the correction of lock-in thermography images for local emissivity variations only leads to minor distortions for standard silicon solar cells. Hence, adequate acquisition of one image only is sufficient to generate a meaningful map of short-circuit current density. Beyond that, this work illustrates the underlying physics of the recently proposed method and demonstrates its robustness concerning varying excitation conditions and locally increased series resistance. Experimentally gained short-circuit current density images are validated for monochromatic illumination in comparison to the reference method of light-beam induced current

  2. Non-invasive method for screening and early detection of breast tumors using thermal field analysis

    Directory of Open Access Journals (Sweden)

    O. Drosu

    2009-10-01

    Full Text Available The paper refers to general presentation of international and European evaluation regarding breast cancer incidence and mortality as well as recommendations for prevention, screening, detection and treatment.The past years international research development in biomedical engineering has put a particular emphasis on the thermography use in breast pathology diagnosis and its main advantages, such as: an early diagnose of the breast cancer, in that stage when the mammography or ultrasounds can not easily detect the changes of the tissue; a totally non-invasive interaction with human body; very low costs and possibilities for the women to do a self thermographic test.We also present some important results of our research within the field of breast tumor detection using the numerical analysis of the thermal inverse problem.

  3. Limits of the values of thermography in the diagnosis of malignomas of the thyroid - compared with scintigraphy and sonography

    International Nuclear Information System (INIS)

    Kaick, G. van

    1976-01-01

    In 250 patients suffering from various diseases of the thyroid, infrared thermography was tried out in addition to the common methods of examination such as scintiscanning, ultrasonic examination, and puncture with fine needles. These examinations were carried out using the camera videosystem made by Messrs. Rank. The thermopictures consist of 20,000 dots and are produced at a rate of 45 pictures per second. The measurements were made after exposing the bare throat to the constant room temperature of 19 0 for 15 minutes for adaptation. The results of the test indicate that most of the malignant growths on the thyroid can be detected by clinical diagnosis alone. The combination of cold scintiscanning, solid sonography, and thermography will probably enable a better and more specific diagnosis. Thermography and sonography alone are not suitable as screening methods for diagnosing malignant growths in the thyroid. (GSE) [de

  4. Commercializing Government-sponsored Innovations: Twelve Successful Buildings Case Studies

    Science.gov (United States)

    Brown, M. A.; Berry, L. G.; Goel, R. K.

    1989-01-01

    This report examines the commercialization and use of R and D results funded by DOE's Office of Buildings and Community Systems (OBCS), an office that is dedicated to improving the energy efficiency of the nation's buildings. Three goals guided the research described in this report: to improve understanding of the factors that hinder or facilitate the transfer of OBCS R and D results, to determine which technology transfer strategies are most effective and under what circumstances each is appropriate, and to document the market penetration and energy savings achieved by successfully-commercialized innovations that have received OBCS support. Twelve successfully-commercialized innovations are discussed here. The methodology employed involved a review of the literature, interviews with innovation program managers and industry personnel, and data collection from secondary sources. Six generic technology transfer strategies are also described. Of these, contracting R and D to industrial partners is found to be the most commonly used strategy in our case studies. The market penetration achieved to date by the innovations studied ranges from less than 1% to 100%. For the three innovations with the highest predicted levels of energy savings (i.e., the flame retention head oil burner, low-E windows, and solid-state ballasts), combined cumulative savings by the year 2000 are likely to approach 2 quads. To date the energy savings for these three innovations have been about 0.2 quads. Our case studies illustrate the important role federal agencies can play in commercializing new technologies.

  5. THE ELM SURVEY. II. TWELVE BINARY WHITE DWARF MERGER SYSTEMS

    International Nuclear Information System (INIS)

    Kilic, Mukremin; Brown, Warren R.; Kenyon, S. J.; Prieto, Carlos Allende; Agueeros, M. A.; Heinke, Craig

    2011-01-01

    We describe new radial velocity and X-ray observations of extremely low-mass white dwarfs (ELM WDs, ∼0.2 M sun ) in the Sloan Digital Sky Survey Data Release 4 and the MMT Hypervelocity Star survey. We identify four new short period binaries, including two merger systems. These observations bring the total number of short period binary systems identified in our survey to 20. No main-sequence or neutron star companions are visible in the available optical photometry, radio, and X-ray data. Thus, the companions are most likely WDs. Twelve of these systems will merge within a Hubble time due to gravitational wave radiation. We have now tripled the number of known merging WD systems. We discuss the characteristics of this merger sample and potential links to underluminous supernovae, extreme helium stars, AM CVn systems, and other merger products. We provide new observational tests of the WD mass-period distribution and cooling models for ELM WDs. We also find evidence for a new formation channel for single low-mass WDs through binary mergers of two lower mass objects.

  6. A study of mammographic and thermographic findings in breast diseases

    International Nuclear Information System (INIS)

    Cho, Won Sik; Jeon, Woo Ki; Kim, Jeong Sook; Han, Chang Yul

    1989-01-01

    The ideal diagnostic methods in breast diseases consist of the physical examination and complementary radiologic examination. In radiologic examination mammography is the most popular screening methods and the older simple complementary method is thermography which is efficient under the conditions of elevated skin temperature in inflammatory and malignant lesions. From Jan. 1st 1987 through Jan. 30th, 1988, 110 pts. with complaints of mammary problems were examined by mammography and thermography at Paik Hospital, Inje University. The authors selected and analyzed 97 cases had been pathologically proved through the operation and the fine needle aspiration biopsy. The results were as follows: 1. The most prevalent age group was 5th decade (40%) in cancer, 4th decade (47%) in mammary dysplasia and followed by fibroadenoma (63%) in 4th decade. 2. The mammographic and thermographic findings were compared between the mammary dysplasia and the infiltrating ductal cancer. In mammary dysplasia abnormal hot emissions were appeared in 9/44 (17%) correlated with atypical hyperchromatic cytoplasm relates to pre-malignant group. 3. We hope and expect the early detection of breast cancer through the follow-up study in pre-malignant group of mammary dysplasia

  7. Cancer diagnosis in a ''breast clinic''. A 15 years retrospection

    Energy Technology Data Exchange (ETDEWEB)

    Ghys, R

    1987-01-01

    Conflicting opinions have been expressed in the world literature over the last 15 years about the value of radiological techniques in breast cancer diagnosis. We reviewed 111 breast cancers which we diagnosed between 1971 and 1985, in unselected patients, by the combined use of palpation, thermography and mammography, complemented, since 1980, by diaphanoscopy. Considerable clinical experience is necessary to interpret both mammograms and thermograms. Each of these approaches, when rated independently, has a very high false negative rate ranging from 41% for clinical examination to 32% for mammography. In cases which are not clinically obvious, diaphanoscopy ''retrieves'' the most cancers, with thermography a close second (definitely malignant in 35% of the cases over the whole age range). Mammography comes third and its efficacy drops to 12.5% in premenopausal women. However, by combining this information with the one derived from anamnesis, the ACDTM scoring system gives us a false negative rate - before biopsy - of 5.5% and a false positive rate of <1%. This approach also drastically reduces the number of unnecessary biopsies.

  8. Infrared thermography applied to monitoring of radioactive waste drums; Termografia infravermelha aplicada ao monitoramento de tambores de rejeitos radioativos

    Energy Technology Data Exchange (ETDEWEB)

    Kelmer, P.; Camarano, D.M. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Calado, F.; Phillip, B.; Viana, C.; Andrade, R.M., E-mail: paulafuziki@yahoo.com.br, E-mail: flavio.arcalado@gmail.com, E-mail: bruno.phil@gmail.com, E-mail: criisviana@hotmail.com, E-mail: rma@ufmg.br, E-mail: dmc@cdtn.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Eletrica

    2013-07-01

    The use of thermography in the inspection of drums containing radioactive waste is being stimulated by the absence of physical contact. In Brazil the majority of radioactive wastes are compacted solids packed in metal drums stored temporarily for decades and requires special attention. These drums have only one qualitative indication of the radionuclides present. However, its structural condition is not followed systematically. The aim of this work is presents a methodology by applying thermography for monitoring the structural condition of drums containing radioactive waste in order to detect degraded regions of the drums. (author)

  9. ThermoPoD: A reliability study on active infrared thermography for the inspection of composite materials

    Energy Technology Data Exchange (ETDEWEB)

    Duan, Yuxia [Beijing Univ. of Aeronautics and Astronautics, Beijing (China); Ibarra-Castanedo, Clemente; Maldague, Xavier P. V. [Univ. Laval, Quebec (Canada); Servais, Pierre; Genest, Marc [National Research Council Canada, Ottawa (Canada)

    2012-07-15

    In this study, a Probability of Detection (PoD) experimental study was carried out in the framework of a Belgian-Quebec/Canada collaborative research project called ThermoPoD. Experiments were implemented on a Carbon Fiber Reinforced Plastic (CFRP) specimen with embedded material simulating delamination. For active infrared thermography, different heating sources (optical or ultrasound), heating forms (pulsed or lock-in), and data processing methods, such as Fourier Transform, Thermal Signal Reconstruction, Wavelet Transform, Differential Absolute Contrast, and Principal Component Thermography are of interest. In the present study, the effects of various data processing methods on PoD curves are compared.

  10. Infrared thermography inspection methods applied to the target elements of W7-X Divertor

    International Nuclear Information System (INIS)

    Missirlian, M.; Durocher, A.; Schlosser, J.; Farjon, J.-L.; Vignal, N.; Traxler, H.; Schedler, B.; Boscary, J.

    2006-01-01

    As heat exhaust capability and lifetime of plasma-facing component (PFC) during in-situ operation are linked to the manufacturing quality, a set of non-destructive testing must be operated during R-and-D and manufacturing phases. Within this framework, advanced non-destructive examination (NDE) methods are one of the key issues to achieve a high level of quality and reliability of joining techniques in the production of high heat flux components but also to develop and built successfully PFCs for a next generation of fusion devices. In this frame, two NDE infrared thermographic approaches, which have been recently applied to the qualification of CFC target elements of the W7-X divertor during the first series production will be discussed in this paper. The first one, developed by CEA (SATIR facility) and used with successfully to the control of the mass-produced actively cooled PFCs on Tore Supra, is based on the transient thermography where the testing protocol consists in inducing a thermal transient within the heat sink structure by an alternative hot/cold water flow. The second one, recently developed by PLANSEE (ARGUS facility), is based on the pulsed thermography where the component is heated externally by a single powerful flash of light. Results obtained on qualification experiences performed during the first series production of W7-X divertor components representing about thirty mock-ups with artificial and manufacturing defects, demonstrated the capabilities of these two methods and raised the efficiency of inspection to a level which is appropriate for industrial application. This comparative study, associated to a cross-checking analysis between the high heat flux performance tests and these inspection methods by infrared thermography, showed a good reproducibility and allowed to set a detectable limit specific at each method. Finally, the detectability of relevant defects showed excellent coincidence with thermal images obtained from high heat flux

  11. Sub-surface defects detection of by using active thermography and advanced image edge detection

    International Nuclear Information System (INIS)

    Tse, Peter W.; Wang, Gaochao

    2017-01-01

    Active or pulsed thermography is a popular non-destructive testing (NDT) tool for inspecting the integrity and anomaly of industrial equipment. One of the recent research trends in using active thermography is to automate the process in detecting hidden defects. As of today, human effort has still been using to adjust the temperature intensity of the thermo camera in order to visually observe the difference in cooling rates caused by a normal target as compared to that by a sub-surface crack exists inside the target. To avoid the tedious human-visual inspection and minimize human induced error, this paper reports the design of an automatic method that is capable of detecting subsurface defects. The method used the technique of active thermography, edge detection in machine vision and smart algorithm. An infrared thermo-camera was used to capture a series of temporal pictures after slightly heating up the inspected target by flash lamps. Then the Canny edge detector was employed to automatically extract the defect related images from the captured pictures. The captured temporal pictures were preprocessed by a packet of Canny edge detector and then a smart algorithm was used to reconstruct the whole sequences of image signals. During the processes, noise and irrelevant backgrounds exist in the pictures were removed. Consequently, the contrast of the edges of defective areas had been highlighted. The designed automatic method was verified by real pipe specimens that contains sub-surface cracks. After applying such smart method, the edges of cracks can be revealed visually without the need of using manual adjustment on the setting of thermo-camera. With the help of this automatic method, the tedious process in manually adjusting the colour contract and the pixel intensity in order to reveal defects can be avoided. (paper)

  12. Thermography for detection of scaling in slurry lines and process vessels

    International Nuclear Information System (INIS)

    Capolingua, Adam; Petrik, Andrew

    2006-01-01

    A major problem in many of today's refineries and mineral processing plants is internal scale build-up within slurry lines and process vessels. Consequences of such an internal scale build-up within lines and vessels include machinery damage, flow restrictions, blockages and localised pipe wear. These problems lead to a loss of production, increased maintenance costs, impinge on worker safety, increase environmental hazards and inevitably reduces profit for the organisation of concern. Hence, the application of an efficient and accurate non-intrusive detection method for locating internal scale within kilometres of lines and numerous process vessels is imperative to reduce maintenance costs and limit production losses. Thermography has been found to be a very useful NDT technique for applications where there is a differential between the ambient and internal product temperatures. The 'insulating' effect of the internal scaling results in a reduced external temperature over the associated area. These temperature differentials can be efficiently detected via a thermographic scan. While this technique is relatively straightforward, the interpretation of the thermographic images usually requires reasonable skill and experience to assess the true extent of each problem detected. In some cases, the true location and extent of scaling within the slurry lines may not be thermally obvious due to the nature of the internal scaling. In such cases, the use of other complementary methods to effectively 'listen'in to the lines has proved to be a valuable procedure. In particular a technology that is typically used in vibration monitoring to assess bearing and gear degradation has been successfully applied in conjunction with thermography to assess lines with localised or dislodged scale. This paper presents a number of case studies where thermography was either applied independently or in conjunction with other measurement techniques, to detect and assess different internal

  13. The quantitative inspection of iron aluminide green sheet using transient thermography

    International Nuclear Information System (INIS)

    Watkins, Michael L.; Hinders, Mark K.; Scorey, Clive; Winfree, William

    1999-01-01

    The recent development of manufacturing techniques for the fabrication of thin iron aluminide, FeAl, sheet requires advanced quantitative methods for on-line inspection. An understanding of the mechanisms responsible for flaws and the development of appropriate flaw detection methods are key elements in an effective quality management system. The first step in the fabrication of thin FeAl alloy sheet is the formation of a green sheet, either by cold rolling or tape casting FeAl powder mixed with organic binding agents. The finished sheet is obtained using a series of process steps involving binder elimination, densification, sintering, and annealing. Non-uniformities within the green sheet are the major contributor to material failure in subsequent sheet processing and the production of non-conforming finished sheet. Previous work has demonstrated the advantages of using active thermography to detect the flaws and heterogeneity within green powder composites (1)(2)(3). The production environment and physical characteristics of these composites provide for unique challenges in developing a rapid nondestructive inspection capability. Thermography is non-contact and minimizes the potential damage to the fragile green sheet. Limited access to the material also demands a one-sided inspection technique. In this paper, we will describe the application of thermography for 100% on-line inspection within an industrial process. This approach is cost competitive with alternative technologies, such as x-ray imaging systems, and provides the required sensitivity to the variations in material composition. The formation of green sheet flaws and their transformation into defects within intermediate and finished sheet products will be described. A green sheet conformance criterion will be presented which would significantly reduce the probability of processing poor quality green sheet which contributes to higher waste and inferior bulk alloy sheet

  14. Research on Defects Inspection of Solder Balls Based on Eddy Current Pulsed Thermography

    Directory of Open Access Journals (Sweden)

    Xiuyun Zhou

    2015-10-01

    Full Text Available In order to solve tiny defect detection for solder balls in high-density flip-chip, this paper proposed feasibility study on the effect of detectability as well as classification based on eddy current pulsed thermography (ECPT. Specifically, numerical analysis of 3D finite element inductive heat model is generated to investigate disturbance on the temperature field for different kind of defects such as cracks, voids, etc. The temperature variation between defective and non-defective solder balls is monitored for defects identification and classification. Finally, experimental study is carried on the diameter 1mm tiny solder balls by using ECPT and verify the efficacy of the technique.

  15. An Overview of Recent Application of Medical Infrared Thermography in Sports Medicine in Austria

    Directory of Open Access Journals (Sweden)

    Carolin Hildebrandt

    2010-05-01

    Full Text Available Medical infrared thermography (MIT is used for analyzing physiological functions related to skin temperature. Technological advances have made MIT a reliable medical measurement tool. This paper provides an overview of MIT´s technical requirements and usefulness in sports medicine, with a special focus on overuse and traumatic knee injuries. Case studies are used to illustrate the clinical applicability and limitations of MIT. It is concluded that MIT is a non-invasive, non-radiating, low cost detection tool which should be applied for pre-scanning athletes in sports medicine.

  16. Outdoor thermal monitoring of large scale structures by infrared thermography integrated in an ICT based architecture

    Science.gov (United States)

    Dumoulin, Jean; Crinière, Antoine; Averty, Rodolphe

    2015-04-01

    An infrared system has been developed to monitor transport infrastructures in a standalone configuration. Results obtained on bridges open to traffic allows to retrieve the inner structure of the decks. To complete this study, experiments were carried out over several months to monitor two reinforced concrete beams of 16 m long and 21 T each. Detection of a damaged area over one of the two beams was made by Pulse Phase Thermography approach. Measurements carried out over several months. Finally, conclusion on the robustness of the system is proposed and perspectives are presented.

  17. Monitoring of a burning conical heap by combining topographical mapping with infrared thermography

    International Nuclear Information System (INIS)

    Carpentier, O.; Antczak, E.; Defer, D.; Duthoit, B.

    2003-01-01

    One of the most used method for monitoring a slag heap is the air infrared thermography. Even if it permit to survey a large area and provide a well contrasted display of dangerous areas, this method is expensive, perturbed by atmospheric conditions and cannot offer an accurate localization of defects. In order to mitigate this disadvantage, the LAMH, in association with Groupe Charbonnages de France, set up a method based on topographic and infrared thermographic cross reading which is more accurate, less expensive and, in a near future, will permit a monitoring of combustion reaction. (authors)

  18. Characterization of an Inclusion of Plastazote Located in an Academic Fresco by Photothermal Thermography

    Science.gov (United States)

    Bodnar, J. L.; Nicolas, J. L.; Mouhoubi, K.; Candore, J. C.; Detalle, V.

    2013-09-01

    The aim of this study is to approach the possibilities of stimulated infrared thermography in dimensional characterization of defects situated in mural paintings. For this purpose, it is suggested to proceed in two stages. First, an in situ longitudinal thermal-diffusivity measurement is developed. Then the characterization of the depth of the studied defect by means of an extended photothermal analysis and a comparison between theory and experiment is carried out. In this article is shown that this approach allows a good estimate of the depth of a plastazote inclusion in a partial copy of the “Saint Christophe” of the Campana collection in the Louvre Museum.

  19. Photothermal Thermography Applied to the Non-destructive Testing of Different Types of Works of Art

    Science.gov (United States)

    Bodnar, J. L.; Mouhoubi, K.; Szatanik-Perrier, G.; Vallet, J. M.; Detalle, V.

    2012-11-01

    In this article, various cases in helping to restore works of art by stimulated infrared thermography are presented. First, the method allows detecting old restorations found on a mural painting in the French senate. Then, it is demonstrated how the photothermal method enables determination of the underlying structure of the mural painting "The Apotheosis of Saint Bruno" in the Charterhouse of Villeneuve-lez-Avignon. Finally, the method allows locating separate canvas paintings on "Avenant de l'aurore" in the "Luxembourg" French Senate building.

  20. Stimulated infrared thermography applied to thermophysical characterization of cultural heritage mural paintings

    Science.gov (United States)

    Bodnar, Jean-Luc; Nicolas, Jean-Louis; Mouhoubi, Kamel; Detalle, Vincent

    2012-11-01

    The purpose of this paper is to approach stimulated infrared thermography possibilities in terms of measuring longitudinal thermal diffusivity of mural paintings in situ. The measuring method principle is first submitted. It is based on temporal analysis of changes in the characteristic radius beams of spatial profiles of the photothermal signal, measured on the spot of the laser excitation. The feasibility of the method is demonstrated, thanks to a series of simulations. Lastly, the method enables to correctly estimate longitudinal thermal diffusivity in a test sample, and further in a fragment copy of "Saint Christophe" belonging to the Campana collection in the Louvre.

  1. Spatially resolved measurements of the magnetocaloric effect and the local magnetic field using thermography

    DEFF Research Database (Denmark)

    Christensen, Dennis; Bjørk, Rasmus; Nielsen, Kaspar Kirstein

    2010-01-01

    The magnetocaloric effect causes a magnetic material to change temperature upon application of a magnetic field. Here, spatially resolved measurements of the adiabatic temperature change are performed on a plate of gadolinium using thermography. The adiabatic temperature change is used to extract...... the corresponding change in the local magnetic field strength. The measured temperature change and local magnetic field strength are compared to results obtained with a numerical model, which takes demagnetization into account and employs experimental data....

  2. Exploitation of condition monitoring technology for equipment by infrared thermography use

    International Nuclear Information System (INIS)

    Shimada, H.

    2005-01-01

    Recently exploitation of condition monitoring technology for equipment by infrared thermography use has been established in US nuclear power plants (NPPs) because of its effectiveness for accidents prevention. Meanwhile, this technology has never been used in Japanese NPPs. In order to make use of it with ease at NPPs, measuring manuals were provided including the table of emissivity dependent on equipment painting specification and measuring positions kept out of background heat sources at measurement. At in-site application tests, temperature increase points at power cable connection parts were discovered, which showed its effectiveness. (T. Tanaka)

  3. Infrared thermography as a diagnostic tool to indicate sick-house-syndrome: a case-study

    Science.gov (United States)

    Ljungberg, Sven-Ake

    1996-03-01

    Every third child and many adults in Sweden have allergic reactions caused by indoor environmental problems. A lot of buildings constructed during the building-boom period of 1950 - 1990 expose the sick-house-syndrome, due to built-in moisture problems and poor ventilation performance of the building. Leaky building construction, transport of humid air condensing on thermal bridges within the construction gives rise to a humid environment, and forms a base for a microbial deterioration process of organic materials, with emissions hazardous for human health. So far there are no universal and cost efficient techniques or methods developed which could be used to reveal the sick-house-syndrome. In this paper we present the results of a case-study of the sick-house-syndrome, and an investigation concept with a combination of different techniques and methods to detect and to map underlying factors that form the base for microbial activities. The concept includes mobile and indoor thermography, functional control of ventilation systems, tracer gas techniques for measurement of air flow exchange rate in different rooms, microbial investigation of emissions, field inspections within the building construction and the building envelope, and medical investigation of the health status of the people working in the building. Mobile thermography of the exterior facades has been performed with a longwave AGEMA THV 900, respectively THV 1000 infrared system, during the period December 1994 - June 1995, at different and similar weather and radiation conditions, and with the building pressurized at one accession. Indoor thermography has been performed with a shortwave AGEMA THV 470 system, for a selection of objects/surfaces with thermal deviations, indicated in thermograms from the different mobile thermographic surveys. Functional control was performed for the ventilation systems, and air flow rates were measured using tracer gas technique for a selection of rooms with different

  4. Nondestructive Inspection of Thin Basalt Fiber Reinforced Composites Using Combined Terahertz Imaging and Infrared Thermography

    Directory of Open Access Journals (Sweden)

    Przemyslaw Lopato

    2016-01-01

    Full Text Available The inspection of thin basalt fiber reinforced composite materials was carried out using two nondestructive methods: terahertz time domain imaging and infrared thermography. In order to combine the information about the defects arising in examined materials the inspection results were parametrized. In order to acquire more information content, new approximation based features are proposed. Then, a knowledge extraction based multivariate analysis of preselected features’ vector was carried out. Finally, in order to integrate features distributions of representing different dynamic level of information, a multiresolution wavelet based data fusion algorithm was applied. The results are presented and discussed.

  5. Comparative analysis of family poultry production in twelve African countries

    International Nuclear Information System (INIS)

    Goodger, W.J.; Bennett, T.B.; Dwinger, R.H.

    2002-01-01

    The purpose of the research was to conduct a survey on family poultry to obtain information on disease prevalence, feeding practices, and the management of poultry housing in twelve African countries. The survey data were collected during both the wet and dry seasons and summarised (average and standard deviation) by country, village/region, season, and survey question. The disease data results show that three (greenish/bloody diarrhoea, swollen head, and coughing) of top four reported symptoms are part of Newcastle disease's presenting signs. Chick mortality was also higher in the wet season, when there is a higher incidence of Newcastle disease. This was also supported by the individual country data in that those countries with high chick mortality data also had low hatchability in the wet season with Egypt being the only exception. The types of housing used for shelter for family poultry was quite variable and presented a challenge to determine the level of cleaning/sanitation to assist in controlling Newcastle disease. On the one hand, a large percentage of households reported never cleaning the poultry house (e.g., Cameroon, Morocco, Mauritius, and Sudan). On the other hand, 34% of the responses to housing type were either trees or other forms of housing that would be difficult to clean i.e., old car, fence, surrounding wall, etc. Obviously, these results should be closely examined when instituting control programs for Newcastle disease. The large variety of available scavenged feed without any data on intake raises the question of how to balance the ration for the flock. Family poultry scientists need to determine a method to estimate intake which could assist in determining what supplementary feed is necessary if any. This challenge may be one of the most important aspects to family poultry management because of the importance of nutrition to poultry production with the added difficulty of providing balanced nutrition in an extensive system. (author)

  6. Commercializing government-sponsored innovations: Twelve successful buildings case studies

    Energy Technology Data Exchange (ETDEWEB)

    Brown, M.A.; Berry, L.G.; Goel, R.K.

    1989-01-01

    This report examines the commercialization and use of R and D results funded by DOE's Office of Buildings and Community Systems (OBCS), an office that is dedicated to improving the energy efficiency of the nation's buildings. Three goals guided the research described in this report: to improve understanding of the factors that hinder or facilitate the transfer of OBCS R and D results, to determine which technology transfer strategies are most effective and under what circumstances each is appropriate, and to document the market penetration and energy savings achieved by successfully-commercialized innovations that have received OBCS support. Twelve successfully-commercialized innovations are discussed here. The methodology employed involved a review of the literature, interviews with innovation program managers and industry personnel, and data collection from secondary sources. Six generic technology transfer strategies are also described. Of these, contracting R and D to industrial partners is found to be the most commonly used strategy in our case studies. The market penetration achieved to date by the innovations studied ranges from less than 1% to 100%. For the three innovations with the highest predicted levels of energy savings (i.e., the flame retention head oil burner, low-E windows, and solid-state ballasts), combined cumulative savings by the year 2000 are likely to approach 2 quads. To date the energy savings for these three innovations have been about 0.2 quads. Our case studies illustrate the important role federal agencies can play in commercializing new technologies. 27 refs., 21 figs., 4 tabs.

  7. Twelve massless flavors and three colors below the conformal window

    International Nuclear Information System (INIS)

    Fodor, Zoltan; Holland, Kieran; Kuti, Julius; Nogradi, Daniel; Schroeder, Chris

    2011-01-01

    We report new results for a frequently discussed gauge theory with twelve fermion flavors in the fundamental representation of the SU(3) color gauge group. The model, controversial with respect to its conformality, is important in non-perturbative studies searching for a viable composite Higgs mechanism beyond the Standard Model (BSM). In comparison with earlier work, our new simulations apply larger volumes and probe deeper in fermion and pion masses toward the chiral limit. Investigating the controversy, we subject the model to opposite hypotheses with respect to the conformal window. In the first hypothesis, below the conformal window, we test chiral symmetry breaking (χSB) with its Goldstone spectrum, F π , the χSB condensate, and several composite hadron states as analytic functions of the fermion mass when varied in a limited range with our best effort to control finite volume effects. In the second test, for the alternate hypothesis inside the conformal window, we probe conformal behavior driven by a single anomalous mass dimension under the assumption of unbroken chiral symmetry at vanishing fermion mass. Our results at fixed gauge coupling, based on the assumptions of the two hypotheses we define, show low level of confidence in the conformal scenario with leading order scaling analysis. Relaxing the important assumption of leading mass-deformed conformality with its conformal finite size scaling would require added theoretical understanding of the scaling violation terms in the conformal analysis and a comprehensive test of its effects on the confidence level of the fits. Results for the running coupling, based on the force between static sources, and preliminary indications for the finite temperature transition are also presented. Staggered lattice fermions with stout-suppressed taste breaking are used throughout the simulations.

  8. Dynamic Infrared Thermography Study of Blood Flow Relative to Lower Limp Position

    Science.gov (United States)

    Stathopoulos, I.; Skouroliakou, K.; Michail, C.; Valais, I.

    2015-09-01

    Thermography is an established method for studying skin temperature distribution. Temperature distribution on body surface is influenced by a variety of physiological mechanisms and has been proven a reliable indicator of various physiological disorders. Blood flow is an important factor that influences body heat diffusion and skin temperature. In an attempt to validate and further elucidate thermal models characterizing the human skin, dynamic thermography of the lower limp in horizontal and vertical position was performed, using a FLIR T460 thermographic camera. Temporal variation of temperature was recorded on five distinct points of the limp. Specific points were initially cooled by the means of an ice cube and measurements of the skin temperature were obtained every 30 seconds as the skin temperature was locally reduced and afterwards restored at its initial value. The return to thermal balance followed roughly the same pattern for all points of measurement, although the heating rate was faster when the foot was in horizontal position. Thermal balance was achieved faster at the spots that were positioned on a vein passage. Our results confirm the influence of blood flow on the thermal regulation of the skin. Spots located over veins exhibit different thermal behaviour due to thermal convection through blood flow. Changing the position of the foot from vertical to horizontal, effectively affects blood perfusion as in the vertical position blood circulation is opposed by gravity.

  9. Application of pulsed flash thermography method for specific defect estimation in aluminum

    Directory of Open Access Journals (Sweden)

    Tomić Ljubiša D.

    2015-01-01

    Full Text Available Nondestructive thermal examination can uncover the presence of defects via temperature distribution profile anomalies that are created on the surface as a result of a defect. There are many factors that affect the temperature distribution map of the surface being tested by Infrared Thermography. Internal defect properties such as thermal conductivity, heat capacity and defect depth, play an important role in the temperature behavior of the pixels or regions being analyzed. Also, it is well known that other external factors such as the convection heat transfer, variations on the surface emissivity and ambient radiation reflectivity can affect the thermographic signal received by the infrared camera. In this paper we considered a simple structure in the form of flat plate covered with several defects, whose surface we heated with a uniform heat flux impulse. We conducted a theoretical analysis and experimental test of the method for case of defects on an aluminum surface. First, experiments were conducted on surfaces with intentionally created defects in order to determine conditions and boundaries for application of the method. Experimental testing of the pulsed flash thermography (PFT method was performed on simulated defects on an aluminum test plate filled with air and organic compound n-hexadecane, hydrocarbon that belongs to the Phase Change Materials (PCMs. Study results indicate that it is possible, using the PFT method, to detect the type of material inside defect holes, whose presence disturbs the homogeneous structure of aluminum.

  10. Extraction of thermal Green's function using diffuse fields: a passive approach applied to thermography

    Science.gov (United States)

    Capriotti, Margherita; Sternini, Simone; Lanza di Scalea, Francesco; Mariani, Stefano

    2016-04-01

    In the field of non-destructive evaluation, defect detection and visualization can be performed exploiting different techniques relying either on an active or a passive approach. In the following paper the passive technique is investigated due to its numerous advantages and its application to thermography is explored. In previous works, it has been shown that it is possible to reconstruct the Green's function between any pair of points of a sensing grid by using noise originated from diffuse fields in acoustic environments. The extraction of the Green's function can be achieved by cross-correlating these random recorded waves. Averaging, filtering and length of the measured signals play an important role in this process. This concept is here applied in an NDE perspective utilizing thermal fluctuations present on structural materials. Temperature variations interacting with thermal properties of the specimen allow for the characterization of the material and its health condition. The exploitation of the thermographic image resolution as a dense grid of sensors constitutes the basic idea underlying passive thermography. Particular attention will be placed on the creation of a proper diffuse thermal field, studying the number, placement and excitation signal of heat sources. Results from numerical simulations will be presented to assess the capabilities and performances of the passive thermal technique devoted to defect detection and imaging of structural components.

  11. Integration of infrared thermography and high-frequency electromagnetic methods in archaeological surveys

    International Nuclear Information System (INIS)

    Carlomagno, Giovanni Maria; Meola, Carosena; Di Maio, Rosa; Fedi, Maurizio

    2011-01-01

    This work is focused on the integration of infrared thermography and ground penetrating radar for the inspection of architectonic structures. First, laboratory tests were carried out with both techniques by considering an ad hoc specimen made of concrete and with the insertion of anomalies of a different nature and at different depths. Such tests provided helpful information for ongoing inspections in situ, which were later performed in two important Italian archaeological sites, namely Pompeii (Naples) and Nora (Cagliari). In the first site, the exploration was devoted to the analysis of the wall paintings of Villa Imperiale with the aim of evaluating the state of conservation of frescoes as well of the underneath masonry structure. As main findings, the applied techniques allowed outlining some areas, which were damaged by ingression in-depth of moisture and/or by disaggregation of the constituent materials, and also for recognition of previous restoration. In the archaeological area of Nora, instead, the attention was driven towards the evaluation of the state of degradation of the theatre remnants. Our prospections show that the front side of the theatre, being more strongly affected by degradation, needs a massive restoration work. As a general result, we demonstrated that a joint interpretation of infrared thermography and ground penetrating radar data supplies detailed 3D information from near-surface to deep layers, which may assist in restoration planning

  12. Use of thermography to monitor sole haemorrhages and temperature distribution over the claws of dairy cattle.

    Science.gov (United States)

    Wilhelm, K; Wilhelm, J; Fürll, M

    2015-02-07

    Subclinical laminitis, an early pathological event in the development of many claw diseases, is an important factor in the welfare and economics of high-producing dairy cows. However, the aetiology and pathogenesis of this complex claw disease are not well understood. The present study investigated to what extent thermographic examination of claws is able to give information about corium inflammation, and whether the technique may be used as a diagnostic tool for early detection of subclinical laminitis. Moreover, the temperature distribution over the individual main claws was investigated to obtain further knowledge about pressure distribution on the claws. For this purpose the claws of 123 cows were evaluated in the first week after calving as well as after the second month of lactation for presence of sole haemorrhages (a sign of subclinical laminitis). Furthermore, the ground contact area was analysed by thermography. Sole haemorrhages were significantly increased by the second month of lactation. Thermography showed clear differences between the claws of the front limbs and hindlimbs, as well as between lateral and medial claws. Although the distribution of sole haemorrhages was consistent with the pattern of the temperature distribution over the main claws, no clear correlation was found between the claw temperature after calving and the visible laminitis-like changes (sole haemorrhages) eight weeks later. British Veterinary Association.

  13. Thermography and Sonic Anemometry to Analyze Air Heaters in Mediterranean Greenhouses

    Directory of Open Access Journals (Sweden)

    Araceli Peña

    2012-10-01

    Full Text Available The present work has developed a methodology based on thermography and sonic anemometry for studying the microclimate in Mediterranean greenhouses equipped with air heaters and polyethylene distribution ducts to distribute the warm air. Sonic anemometry allows us to identify the airflow pattern generated by the heaters and to analyze the temperature distribution inside the greenhouse, while thermography provides accurate crop temperature data. Air distribution by means of perforated polyethylene ducts at ground level, widely used in Mediterranean-type greenhouses, can generate heterogeneous temperature distributions inside the greenhouse when the system is not correctly designed. The system analyzed in this work used a polyethylene duct with a row of hot air outlet holes (all of equal diameter that expel warm air toward the ground to avoid plant damage. We have observed that this design (the most widely used in Almería’s greenhouses produces stagnation of hot air in the highest part of the structure, reducing the heating of the crop zone. Using 88 kW heating power (146.7 W∙m−2 the temperature inside the greenhouse is maintained 7.2 to 11.2 °C above the outside temperature. The crop temperature (17.6 to 19.9 °C was maintained above the minimum recommended value of 10 °C.

  14. Thermography and sonic anemometry to analyze air heaters in Mediterranean greenhouses.

    Science.gov (United States)

    López, Alejandro; Valera, Diego L; Molina-Aiz, Francisco; Peña, Araceli

    2012-10-16

    The present work has developed a methodology based on thermography and sonic anemometry for studying the microclimate in Mediterranean greenhouses equipped with air heaters and polyethylene distribution ducts to distribute the warm air. Sonic anemometry allows us to identify the airflow pattern generated by the heaters and to analyze the temperature distribution inside the greenhouse, while thermography provides accurate crop temperature data. Air distribution by means of perforated polyethylene ducts at ground level, widely used in Mediterranean-type greenhouses, can generate heterogeneous temperature distributions inside the greenhouse when the system is not correctly designed. The system analyzed in this work used a polyethylene duct with a row of hot air outlet holes (all of equal diameter) that expel warm air toward the ground to avoid plant damage. We have observed that this design (the most widely used in Almería's greenhouses) produces stagnation of hot air in the highest part of the structure, reducing the heating of the crop zone. Using 88 kW heating power (146.7 W ∙ m(-2)) the temperature inside the greenhouse is maintained 7.2 to 11.2 °C above the outside temperature. The crop temperature (17.6 to 19.9 °C) was maintained above the minimum recommended value of 10 °C.

  15. Integral methods of active infrared thermography; Integrale Verfahren der aktiven Infrarotthermografie

    Energy Technology Data Exchange (ETDEWEB)

    Schlichting, Joachim

    2012-07-01

    Non-destructive evaluation is a task of utmost importance for both, the economic point of view and to guarantee the required safety and reliability of technical systems. Thermography is a fast and contactless technique which received continued attention not least through the significant price drop at the infrared camera market. It is typically used to detect near-surface defects which are expanded parallel to the surface. This thesis deals with two non-standard inspection tasks. With the weld lens diameter of spot welds, a feature in the sample's geometrical center is indirectly sized by flash thermography. The presented method is suitable to distinguish typical error classes like stick welds or expulsions. This fact is validated by statistical evaluations of thermographic and destructive test series. As an example for perpendicularly oriented imperfections, surface cracks are investigated, which can be a major problem at welding seams. A technique for detecting cracks entirely based on commercially available equipment is developed. In addition, the accessibility of geometric characteristics of cracks was examined by experiments and FEM-simulations. Similar to the method developed for assessing spot welds, an approach based on the analysis of spatial and temporal integral quantities which depend on the thermal resistance is used. In doing so, the simultaneous determination of crack angle and depth is possible.

  16. Building thermography as a tool in energy audits and building commissioning procedure

    Science.gov (United States)

    Kauppinen, Timo

    2007-04-01

    A Building Commissioning-project (ToVa) was launched in Finland in the year 2003. A comprehensive commissioning procedure, including the building process and operation stage was developed in the project. This procedure will confirm the precise documentation of client's goals, definition of planning goals and the performance of the building. It is rather usual, that within 1-2 years after introduction the users complain about the defects or performance malfunctions of the building. Thermography is one important manual tool in verifying the thermal performance of the building envelope. In this paper the results of one pilot building (a school) will be presented. In surveying the condition and energy efficiency of buildings, various auxiliary means are needed. We can compare the consumption data of the target building with other, same type of buildings by benchmarking. Energy audit helps to localize and determine the energy saving potential. The most general and also most effective auxiliary means in monitoring the thermal performance of building envelopes is an infrared camera. In this presentation some examples of the use of thermography in energy audits are presented.

  17. Comparative Analysis of Infrared Thermography and CFD Modelling for Assessing the Thermal Performance of Buildings

    Directory of Open Access Journals (Sweden)

    Carlos Morón

    2018-03-01

    Full Text Available Energy consumption in the building sector has increased significantly in the developed countries over the last decades. For this reason, the new European standards have become stricter in terms of energy saving. This paper establishes a comparison between using infrared thermography for technical building inspection and modelling with Computational Flow Dynamics (CFD tools for the study of thermal performance of the building. The results show that the use of this type of tools gives a reliable response with the difference in thermal changes lower than 0.5 °C with respect to the data taken in situ. Moreover, these simulators of flow dynamics allow to evaluate the efficiency of proposed measures for energy savings and to obtain a reliable approximation to thermal comfort applying the improvement, deepening in the surface analysis of infrared thermography before performing rehabilitation project. In this research, Predicted Mean Vote Index (PMV comfort index of 0.7 for a living room and 0.6 for a bedroom were obtained, that corresponds to C class that includes values in the range of −0.7 < PMV < 0.7 according to the standard UNE-EN 7730.

  18. Color Segmentation Approach of Infrared Thermography Camera Image for Automatic Fault Diagnosis

    International Nuclear Information System (INIS)

    Djoko Hari Nugroho; Ari Satmoko; Budhi Cynthia Dewi

    2007-01-01

    Predictive maintenance based on fault diagnosis becomes very important in current days to assure the availability and reliability of a system. The main purpose of this research is to configure a computer software for automatic fault diagnosis based on image model acquired from infrared thermography camera using color segmentation approach. This technique detects hot spots in equipment of the plants. Image acquired from camera is first converted to RGB (Red, Green, Blue) image model and then converted to CMYK (Cyan, Magenta, Yellow, Key for Black) image model. Assume that the yellow color in the image represented the hot spot in the equipment, the CMYK image model is then diagnosed using color segmentation model to estimate the fault. The software is configured utilizing Borland Delphi 7.0 computer programming language. The performance is then tested for 10 input infrared thermography images. The experimental result shows that the software capable to detect the faulty automatically with performance value of 80 % from 10 sheets of image input. (author)

  19. Evaluation of stator core loss of high speed motor by using thermography camera

    Science.gov (United States)

    Sato, Takeru; Enokizono, Masato

    2018-04-01

    In order to design a high-efficiency motor, the iron loss that is generated in the motor should be reduced. The iron loss of the motor is generated in a stator core that is produced with an electrical steel sheet. The iron loss characteristics of the stator core and the electrical steel sheet are agreed due to a building factor. To evaluate the iron loss of the motor, the iron loss of the stator core should be measured more accurately. Thus, we proposed the method of the iron loss evaluation of the stator core by using a stator model core. This stator model core has been applied to the surface mounted permanent magnet (PM) motors without windings. By rotate the permanent magnet rotor, the rotating magnetic field is generated in the stator core like a motor under driving. To evaluate the iron loss of the stator model core, the iron loss of the stator core can be evaluated. Also, the iron loss can be calculated by a temperature gradient. When the temperature gradient is measured by using thermography camera, the iron loss of entire stator core can be evaluated as the iron loss distribution. In this paper, the usefulness of the iron loss evaluation method by using the stator model core is shown by the simulation with FEM and the heat measurement with thermography camera.

  20. Lock-in thermography as a rapid and reproducible thermal characterization method for magnetic nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Lemal, Philipp; Geers, Christoph; Monnier, Christophe A.; Crippa, Federica; Daum, Leopold; Urban, Dominic A.; Rothen-Rutishauser, Barbara [Adolphe Merkle Institute, University of Fribourg, Chemin des Verdiers 4, CH-1700 Fribourg (Switzerland); Bonmarin, Mathias, E-mail: mathias.bonmarin@zhaw.ch [Institute of Computational Physics, Zurich University of Applied Sciences, Technikumstrasse 9, 8400 Winterthur (Switzerland); Petri-Fink, Alke, E-mail: alke.fink@unifr.ch [Adolphe Merkle Institute, University of Fribourg, Chemin des Verdiers 4, CH-1700 Fribourg (Switzerland); Chemistry Department, University of Fribourg, Chemin du Museé 9, CH-1700 Fribourg (Switzerland); Moore, Thomas L., E-mail: thomaslee.moore@unifr.ch [Adolphe Merkle Institute, University of Fribourg, Chemin des Verdiers 4, CH-1700 Fribourg (Switzerland)

    2017-04-01

    Lock-in thermography (LIT) is a sensitive imaging technique generally used in engineering and materials science (e.g. detecting defects in composite materials). However, it has recently been expanded for investigating the heating power of nanomaterials, such as superparamagnetic iron oxide nanoparticles (SPIONs). Here we implement LIT as a rapid and reproducible method that can evaluate the heating potential of various sizes of SPIONs under an alternating magnetic field (AMF), as well as the limits of detection for each particle size. SPIONs were synthesized via thermal decomposition and stabilized in water via a ligand transfer process. Thermographic measurements of SPIONs were made by stimulating particles of varying sizes and increasing concentrations under an AMF. Furthermore, a commercially available SPION sample was included as an external reference. While the size dependent heating efficiency of SPIONs has been previously described, our objective was to probe the sensitivity limits of LIT. For certain size regimes it was possible to detect signals at concentrations as low as 0.1 mg Fe/mL. Measuring at different concentrations enabled a linear regression analysis and extrapolation of the limit of detection for different size nanoparticles. - Highlights: • A multi-sample screening assessment of magnetic nanoparticle thermal characteristics is shown via lock-in thermography. • Lower concentration limit of nanoparticle detection based on particle size is proposed. • A commercially available reference sample indicates the stability and reproducibility of LIT.

  1. Analysis of pulse thermography using similarities between wave and diffusion propagation

    Science.gov (United States)

    Gershenson, M.

    2017-05-01

    Pulse thermography or thermal wave imaging are commonly used as nondestructive evaluation (NDE) method. While the technical aspect has evolve with time, theoretical interpretation is lagging. Interpretation is still using curved fitting on a log log scale. A new approach based directly on the governing differential equation is introduced. By using relationships between wave propagation and the diffusive propagation of thermal excitation, it is shown that one can transform from solutions in one type of propagation to the other. The method is based on the similarities between the Laplace transforms of the diffusion equation and the wave equation. For diffusive propagation we have the Laplace variable s to the first power, while for the wave propagation similar equations occur with s2. For discrete time the transformation between the domains is performed by multiplying the temperature data vector by a matrix. The transform is local. The performance of the techniques is tested on synthetic data. The application of common back projection techniques used in the processing of wave data is also demonstrated. The combined use of the transform and back projection makes it possible to improve both depth and lateral resolution of transient thermography.

  2. Active Thermography for the Detection of Defects in Powder Metallurgy Compacts

    International Nuclear Information System (INIS)

    Benzerrouk, Souheil; Ludwig, Reinhold; Apelian, Diran

    2007-01-01

    Active thermography is an established NDE technique that has become the method of choice in many industrial applications which require non-contact access to the parts under test. Unfortunately, when conducting on-line infrared (IR) inspection of powder metallic compacts, complications can arise due the generally low emissivity of metals and the thermally noisy environment typically encountered in manufacturing plants. In this paper we present results of an investigation that explores the suitability of active IR imaging of powder metallurgy compacts for the detection of surface and sub-surface defects in the pre-sinter state and in an on-line manufacturing setting to ensure complete quality assurance. Additional off-line tests can be carried out for statistical quality analyses. In this research, the IR imaging of sub-surface defects is based on a transient instrumentation approach that relies on an electric control system which synchronizes and monitors the thermal response due to an electrically generated heat source. Preliminary testing reveals that this newly developed pulsed thermography system can be employed for the detection of subsurface defects in green-state parts. Practical measurements agree well with theoretical predictions. The inspection approach being developed can be used for the testing of green-state compacts as they exit the compaction press at speeds of up to 1,000 parts per hour

  3. ON-POWER DETECTION OF PIPE WALL-THINNED DEFECTS USING IR THERMOGRAPHY IN NPPS

    Directory of Open Access Journals (Sweden)

    JU HYUN KIM

    2014-04-01

    Full Text Available Wall-thinned defects caused by accelerated corrosion due to fluid flow in the inner pipe appear in many structures of the secondary systems in nuclear power plants (NPPs and are a major factor in degrading the integrity of pipes. Wall-thinned defects need to be managed not only when the NPP is under maintenance but also when the NPP is in normal operation. To this end, a test technique was developed in this study to detect such wall-thinned defects based on the temperature difference on the surface of a hot pipe using infrared (IR thermography and a cooling device. Finite element analysis (FEA was conducted to examine the tendency and experimental conditions for the cooling experiment. Based on the FEA results, the equipment was configured before the cooling experiment was conducted. The IR camera was then used to detect defects in the inner pipe of the pipe specimen that had artificially induced defects. The IR thermography developed in this study is expected to help resolve the issues related to the limitations of non-destructive inspection techniques that are currently conducted for NPP secondary systems and is expected to be very useful on the NPPs site.

  4. High-definition infrared thermography of ice nucleation and propagation in wheat under natural frost conditions and controlled freezing

    Science.gov (United States)

    Infrared thermography has been used to visualize the freezing process in plants and has greatly enhanced our knowledge of ice nucleation and propagation in plants. The majority of IR analyses have been conducted under controlled rather than natural conditions and often on plant parts instead of wh...

  5. Low-temperature infiltration identified using infrared thermography in patients with subcutaneous edema revealed ultrasonographically: A case report.

    Science.gov (United States)

    Oya, Maiko; Takahashi, Toshiaki; Tanabe, Hidenori; Oe, Makoto; Murayama, Ryoko; Yabunaka, Koichi; Matsui, Yuko; Sanada, Hiromi

    Infiltration is a frequent complication of infusion therapy. We previously demonstrated the usefulness of infrared thermography as an objective method of detecting infiltration in healthy people. However, whether thermography can detect infiltration in clinical settings remains unknown. Therefore, we report two cases where thermography was useful in detecting infiltration at puncture sites. In both cases, tissue changes were verified ultrasonographically. The patients were a 56-year-old male with cholangitis and a 76-year-old female with hepatoma. In both cases, infiltration symptoms such as swelling and erythema occurred one day after the insertion of a peripheral intravenous catheter. Thermographic images from both patients revealed low-temperature areas spreading from the puncture sites; however, these changes were not observed in other patients. The temperature difference between the low-temperature areas and their surrounding skin surface exceeded 1.0°C. Concurrently, ultrasound images revealed that tissues surrounding the vein had a cobblestone appearance, indicating edema. In both patients, subcutaneous tissue changes suggested infiltration and both had low-temperature areas spreading from the puncture sites. Thus, subcutaneous edema may indicate infusion leakage, resulting in a decrease in the temperature of the associated skin surface. These cases suggest that infrared thermography is an effective method of objectively and noninvasively detecting infiltration.

  6. Breast Gangrene

    Directory of Open Access Journals (Sweden)

    Husasin Irfan

    2011-08-01

    Full Text Available Abstract Background Breast gangrene is rare in surgical practice. Gangrene of breast can be idiopathic or secondary to some causative factor. Antibiotics and debridement are used for management. Acute inflammatory infiltrate, severe necrosis of breast tissue, necrotizing arteritis, and venous thrombosis is observed on histopathology. The aim of was to study patients who had breast gangrene. Methods A prospective study of 10 patients who had breast gangrene over a period of 6 years were analyzed Results All the patients in the study group were female. Total of 10 patients were encountered who had breast gangrene. Six patients presented with breast gangrene on the right breast whereas four had on left breast. Out of 10 patients, three had breast abscess after teeth bite followed by gangrene, one had iatrogenic trauma by needle aspiration of erythematous area of breast under septic conditions. Four had history of application of belladonna on cutaneous breast abscess and had then gangrene. All were lactating female. Amongst the rest two were elderly, one of which was a diabetic who had gangrene of breast and had no application of belladonna. All except one had debridement under cover of broad spectrum antibiotics. Three patients had grafting to cover the raw area. Conclusion Breast gangrene occurs rarely. Etiology is variable and mutifactorial. Teeth bite while lactation and the iatrogenic trauma by needle aspiration of breast abscess under unsterlised conditions could be causative. Uncontrolled diabetes can be one more causative factor for the breast gangrene. Belladonna application as a topical agent could be inciting factor. Sometimes gangrene of breast can be idiopathic. Treatment is antibiotics and debridement.

  7. Breast Exam

    Science.gov (United States)

    ... ends. What you can expect Begin with a visual examination of your breasts Sit or stand shirtless ... to the next section. If you have a disability that makes it difficult to examine your breasts ...

  8. Breast cancer

    African Journals Online (AJOL)

    A collaborative article gives an overview of breast cancer in LICs, ... approach to the problem; therefore they are published as two separate ... attached to the diagnosis of breast cancer. ... Their founding statement in its early form is included.

  9. Breast Cancer

    Science.gov (United States)

    Breast cancer affects one in eight women during their lives. No one knows why some women get breast cancer, but there are many risk factors. Risks that ... who have family members with breast or ovarian cancer may wish to be tested for the genes. ...

  10. Public health advocacy in action: the case of unproven breast cancer screening in Australia.

    Science.gov (United States)

    Johnson, Rebecca S; Croager, Emma J; Kameron, Caitlin B; Pratt, Iain S; Vreugdenburg, Thomas D; Slevin, Terry

    2016-09-30

    In recent years, nonmammographic breast imaging devices, such as thermography, electrical impedance scanning and elastography, have been promoted directly to consumers, which has captured the attention of governments, researchers and health organisations. These devices are not supported by evidence and risk undermining existing mammographic breast cancer screening services. During a 5-year period, Cancer Council Western Australia (CCWA) used strategic research combined with legal, policy and media advocacy to contest claims that these devices were proven alternatives to mammography for breast cancer screening. The campaign was successful because it had input from people with public health, academic, clinical and legal backgrounds, and took advantage of existing legal and regulatory avenues. CCWA's experience provides a useful advocacy model for public health practitioners who are concerned about unsafe consumer products, unproven medical devices, and misleading health information and advertising.

  11. Use of infrared thermography for the diagnosis and grading of sprained ankle injuries

    Science.gov (United States)

    Oliveira, João; Vardasca, Ricardo; Pimenta, Madalena; Gabriel, Joaquim; Torres, João

    2016-05-01

    Ankle joint sprains are a common medical condition estimated to be responsible for 15-25% of all musculoskeletal injuries worldwide. The pathophysiology of the lesion can represent considerable time lost to injury, as well as long-term disability in up to 60% of patients. A percentage between 10% and 20% may complicate with chronic instability of the ankle joint and disability in walking, contributing to morbidity and poor life quality. Ankle sprains can be classified as grade I, II, or III, based on the extent of damage and number of ligaments affected. The diagnostic grading is important for setting further treatment and rehabilitation, since more severe injuries carries risk of recurrence, added morbidity and decrease in life quality. The aim of this work was to evaluate the adequacy of infrared thermography as a potential complimentary diagnostic tool of the distinct lesions grades. Evaluation of different thermographic values of the ankle region (in both affected and non-affected foot) was conducted for this purpose. The principal results to be highlighted are that some of the regions, namely anterior view for non defined time after injury analysis, and anterior, frontal, posterior and anterior talofibular ligament regions and proximal calcaneofibular ligament regions in acute lesions (herein defined as less than 6 h post-traumatic event) presented consistent profiles of variation. The analyses were performed considering affected and non-affected ankles results on plotted graphics representing termographic evaluation and grading of these lesions performed using ultrasound by experimented medical radiologists. An increase in temperature values was observed when progressing from mild to severe ankle sprain injuries, with these regions presenting lower values for the affected ankle when compared to the non-affected ankle in all the analysis performed. The remaining analysed regions did not present the same variations. Statistical analysis using Kruskal

  12. A portable thermal imaging device as a feedback system for breast cancer treatment

    Science.gov (United States)

    Hoffer, Oshrit A.; Ben-David, Merav A.; Katz, Eyal; Sholomov, Meny; Kelson, Itzhak; Gannot, Israel

    2018-02-01

    Breast cancer is the most frequently diagnosed cancer among women in the Western world. Currently, no imaging technique assesses tumor heat generation and vasculature changes during radiotherapy in viable tumor and as adjuvant therapy. Thermography is a non-ionizing, non-invasive, portable and low-cost imaging modality. The purpose of this study was to investigate the use of thermography in cancer treatment monitoring for feedback purposes. Six stage-IV breast cancer patients with viable breast tumor and 8 patients (9 breasts) who underwent tumor resection were monitored by a thermal camera prior to radiotherapy sessions over several weeks of radiation treatment. The thermal changes over the treated breast were calculated and analyzed for comparison with healthy surrounded breast tissue or contralateral breast. A model of a breast with a tumor was created. The COMSOL FEM software was used to carry out the analysis. The effects of tumor metabolism and breast tissue perfusion on the temperature difference were analyzed. All patients with active tumors exhibited drops in maximal temperature of the tumor during radiation therapy. The patients who underwent radiotherapy as adjuvant treatment exhibited a rise in maximal temperature over the treated breast in correlation with skin erythema during radiation. This difference between the groups was statistically significant (P=0.001). The simulated human breast cancer models analysis showed that tumor aggressiveness reduction causes decrease in the tumor temperature. Inflammation causes vasodilatation and increases tissue perfusion, resulted in an increase in breast tissue temperature. A correlation was demonstrated between the clinical outcome and the simulation. We report a method for monitoring cancer response to radiation therapy, which measures the physiological response along with clinical response. These anticipatory efficacy evaluations of radiotherapy during treatment may further promote changes in treatment regimen

  13. In-flight investigations of the unsteady behaviour of the boundary layer with infrared thermography

    Science.gov (United States)

    Szewczyk, Mariusz; Smusz, Robert; de Groot, Klaus; Meyer, Joerg; Kucaba-Pietal, Anna; Rzucidlo, Pawel

    2017-04-01

    Infrared thermography (IRT) has been well established in wind tunnel and flight tests for the last decade. Former applications of IRT were focused, in nearly all cases, on steady measurements. In the last years, requirements of unsteady IRT measurements (up to 10 Hz) have been formulated, but the problem of a very slow thermal response of common materials of wind tunnel models or airplane components has to be overcome by finding a surface modification with a fast thermal response (low heat capacity, low thermal conductivity and high thermal diffusivity). Therefore, lab investigations of potential material combinations and flight tests with a ‘low cost’ aircraft, i.e. a glider with a modified wing surface, were conducted. In order to induce unsteady conditions (rapid change of laminar-turbulent boundary layer transition), special maneuvers of a glider during IRT measurements were performed.

  14. Validation of infrared thermography in serotonin-induced itch model in rats

    DEFF Research Database (Denmark)

    Dagnæs-Hansen, Frederik; Jasemian, Yousef; Gazerani, Parisa

    The number of scratching bouts is generally used as a standard method in animal models of itch. The aim of the present study was to validate the application of infrared thermography (IR-Th) in a serotonin-induced itch model in rats. Adult Sprague-Dawley male rats (n = 24) were used in 3 consecutive...... experiments. The first experiment evaluated vasomotor response (IR-Th) and scratching behavior (number of bouts) induced by intradermal serotonin (10 μl, 2%). Isotonic saline (control: 10 μl, 0.9%) and Methysergide (antagonist: 10 μl, 0.047 mg/ml) were used. The second experiment evaluated the dose......-response effect of intradermal serotonin (1%, 2% and 4%) on local temperature. The third experiment evaluated the anesthetized rats to test the local vasomotor responses in absent of scratching. Serotonin elicited significant scratching and lowered the local temperature at the site of injection. A dose...

  15. Standard practice for infrared flash thermography of composite panels and repair patches used in aerospace applications

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This practice describes a procedure for detecting subsurface flaws in composite panels and repair patches using Flash Thermography (FT), in which an infrared (IR) camera is used to detect anomalous cooling behavior of a sample surface after it has been heated with a spatially uniform light pulse from a flash lamp array. 1.2 This practice describes established FT test methods that are currently used by industry, and have demonstrated utility in quality assurance of composite structures during post-manufacturing and in-service examinations. 1.3 This practice has utility for testing of polymer composite panels and repair patches containing, but not limited to, bismaleimide, epoxy, phenolic, poly(amide imide), polybenzimidazole, polyester (thermosetting and thermoplastic), poly(ether ether ketone), poly(ether imide), polyimide (thermosetting and thermoplastic), poly(phenylene sulfide), or polysulfone matrices; and alumina, aramid, boron, carbon, glass, quartz, or silicon carbide fibers. Typical as-fabricate...

  16. A novel pulse compression algorithm for frequency modulated active thermography using band-pass filter

    Science.gov (United States)

    Chatterjee, Krishnendu; Roy, Deboshree; Tuli, Suneet

    2017-05-01

    This paper proposes a novel pulse compression algorithm, in the context of frequency modulated thermal wave imaging. The compression filter is derived from a predefined reference pixel in a recorded video, which contains direct measurement of the excitation signal alongside the thermal image of a test piece. The filter causes all the phases of the constituent frequencies to be adjusted to nearly zero value, so that on reconstruction a pulse is obtained. Further, due to band-limited nature of the excitation, signal-to-noise ratio is improved by suppressing out-of-band noise. The result is similar to that of a pulsed thermography experiment, although the peak power is drastically reduced. The algorithm is successfully demonstrated on mild steel and carbon fibre reference samples. Objective comparisons of the proposed pulse compression algorithm with the existing techniques are presented.

  17. Infrared thermography based on artificial intelligence as a screening method for carpal tunnel syndrome diagnosis.

    Science.gov (United States)

    Jesensek Papez, B; Palfy, M; Mertik, M; Turk, Z

    2009-01-01

    This study further evaluated a computer-based infrared thermography (IRT) system, which employs artificial neural networks for the diagnosis of carpal tunnel syndrome (CTS) using a large database of 502 thermal images of the dorsal and palmar side of 132 healthy and 119 pathological hands. It confirmed the hypothesis that the dorsal side of the hand is of greater importance than the palmar side when diagnosing CTS thermographically. Using this method it was possible correctly to classify 72.2% of all hands (healthy and pathological) based on dorsal images and > 80% of hands when only severely affected and healthy hands were considered. Compared with the gold standard electromyographic diagnosis of CTS, IRT cannot be recommended as an adequate diagnostic tool when exact severity level diagnosis is required, however we conclude that IRT could be used as a screening tool for severe cases in populations with high ergonomic risk factors of CTS.

  18. An Exploratory Study on the Optimized Test Conditions of the Lock-in Thermography Technique

    International Nuclear Information System (INIS)

    Cho, Yong Jin

    2011-01-01

    This work is devoted to the technique application of lock-in infrared thermography in the shipbuilding and ocean engineering industry. For this purpose, an exploratory study to find the optimized test conditions is carried out by the design of experiments. It has been confirmed to be useful method that the phase contrast images were quantified by a reference image and weighted by defect hole size. Illuminated optical intensity of lower or medium strength give a good result for getting a phase contrast image. In order to get a good phase contrast image, lock-in frequency factors should be high in proportion to the illuminated optical intensity. The integration time of infrared camera should have been inversely proportional to the optical intensity. The other hand, the difference of specimen materials gave a slightly biased results not being discriminative reasoning

  19. Development of LabVIEW Program for Lock-In Infrared Thermography

    International Nuclear Information System (INIS)

    Min, Tae Hoon; Na, Hyung Chul; Kim, Noh Yu

    2011-01-01

    A LabVIEW program has been developed together with simple infrared thermography(IRT) system to control the lock-in conditions of the system efficiently. The IR imaging software was designed to operate both of infrared camera and halogen lamp by synchronizing them with periodic sine signal based on thyristor(SCR) circuits. LabVIEW software was programmed to provide users with screen-menu functions by which it can change the period and energy of heat source, operate the camera to acquire image, and monitor the state of the system on the computer screen In experiment, lock-in IR image for a specimen with artificial hole defects was obtained by the developed IRT system and compared with optical image

  20. Active infrared thermography for visualizing subsurface micro voids in an epoxy molding compound

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Ji Yeol [Test and Package Center, Samsung Electronics, Asan(Korea, Republic of); Hwang, Soon Kyu; Choi, Jae Mook; Sohn, Hoon [Dept. of Civil and Environmental Engineering, Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2017-04-15

    This paper presents an automated subsurface micro void detection technique based on pulsed infrared thermography for inspecting epoxy molding compounds (EMC) used in electronic device packaging. Subsurface micro voids are first detected and visualized by extracting a lock-in amplitude image from raw thermal images. Binary imaging follows to achieve better visualization of subsurface micro voids. A median filter is then applied for removing sparse noise components. The performance of the proposed technique is tested using 36 EMC samples, which have subsurface (below 150 μm ~ 300 μm from the inspection surface) micro voids (150 μm ~ 300 μm in diameter). The experimental results show that the subsurface micro voids can be successfully detected without causing any damage to the EMC samples, making it suitable for automated online inspection.

  1. Aerial thermography from low-cost UAV for the generation of thermographic digital terrain models

    Science.gov (United States)

    Lagüela, S.; Díaz-Vilariño, L.; Roca, D.; Lorenzo, H.

    2015-03-01

    Aerial thermography is performed from a low-cost aerial vehicle, copter type, for the acquisition of data of medium-size areas, such as neighbourhoods, districts or small villages. Thermographic images are registered in a mosaic subsequently used for the generation of a thermographic digital terrain model (DTM). The thermographic DTM can be used with several purposes, from classification of land uses according to their thermal response to the evaluation of the building prints as a function of their energy performance, land and water management. In the particular case of buildings, apart from their individual evaluation and roof inspection, the availability of thermographic information on a DTM allows for the spatial contextualization of the buildings themselves and the general study of the surrounding area for the detection of global effects such as heat islands.

  2. Characterization of defects situated in a fresco by stimulated infrared thermography

    Science.gov (United States)

    Candoré, J. C.; Bodnar, J. L.; Detalle, V.; Grossel, P.

    2012-01-01

    The objective of this work is to approach the possibilities of stimulated infrared thermography in dimensional characterization of defects situated in mural paintings. Towards this end, we have proceeded in two stages. Initially, we have developed, with the help of a point source photothermal analysis, an in situ measurement of the longitudinal thermal diffusivity parameter. Then, we have proceeded to the characterization of the depth of the studied defect, by means of a wide photothermal analysis and of a confrontation between theory and experiment. In this article, we present these two measurement techniques and show that the approach allows a good estimation of the depth of an inclusion of plastazote in a copy of the "Saint Christophe" of the "Campana" collection of the "Louvre Museum".

  3. Non-destructive testing of works of art by stimulated infrared thermography

    Science.gov (United States)

    Candoré, J. C.; Bodnar, J. L.; Detalle, V.; Grossel, P.

    2012-02-01

    In this work, we present various examples of assistance to the restoration of works of art by stimulated infrared thermography. We show initially that the method allows the detection of delamination located in mural paintings, such as in the "Saint Christophe" of the Campana collection of the Louvre French museum. We show then that it also makes it possible to detect delaminations or galleries of worms in marquetries. We show in a third stage that it provides for the detection of detachment of grayness in stained glasses. We show in a fourth stage that it allows the visualization of shards or metal inserts located in a Greek "panathénaque" amphora of the French National museum of the Ceramics of Sevres. We show finally, that the method permits the detection of a crack located in an ovoid vase of the same French National museum of the Ceramics of Sevres.

  4. Contribution to the improvement of heritage mural painting non-destructive testing by stimulated infrared thermography

    Science.gov (United States)

    Bodnar, Jean-Luc; Mouhoubi, Kamel; Di Pallo, Luigi; Detalle, Vincent; Vallet, Jean-Marc; Duvaut, Thierry

    2013-10-01

    Non-destructive testing of heritage mural paintings by means of stimulated infrared thermography has now become rather efficient [1-14]. However, pigments, which form a pictorial layer, have contrasting radiative properties possibly leading to artifact detection. In this paper, attempts to alleviate this difficulty are presented. Based on the spectroscopic study of different paint layers, one can argue that, in the medium infrared field, this radiative disparity decreases significantly. Then, with similar settings, it can be shown that ceramic radiative sources allow reaching this wavelength band. Finally, on the basis of a study carried out on an academic sample and a partial copy of a fresco from the cathedral of Angers, combining ceramic heat sources with a laboratory SAMMTHIR experimental setup enables to make real headway in terms of defects' detection.

  5. Refinement of the Collagen Induced Arthritis Model in Rats by Infrared Thermography

    DEFF Research Database (Denmark)

    Jasemian, Yousef; Deleuran, Bent Winding; Svendsen, Pia

    2011-01-01

    correlation between temperature and clinical scores. Conclusion: The thermographic response appeared prior to the clinical signs, suggesting that thermography may be used as a predictive sign for the development of disease. This technique could be a non-invasive, objective, rapid, and reproducible method...... with other clinical parameters such as clinical score and edema and may serve as a method for quantification of the degree of inflammation. Study design: Experimental animal study. Place and Duration of Study: Institute of Biomedicine, University of Aarhus, Denmark between February and March 2010....... Methodology: Arthritis was induced with collagen immunization in sixteen Lewis rats. Four of the animals were treated with dexamethasone to function as negative controls. Clinical scores were based on the magnitude of paw edema. The mean temperature of the hind feet (region covering the metatarsus and tarsus...

  6. Spatial-time-state fusion algorithm for defect detection through eddy current pulsed thermography

    Science.gov (United States)

    Xiao, Xiang; Gao, Bin; Woo, Wai Lok; Tian, Gui Yun; Xiao, Xiao Ting

    2018-05-01

    Eddy Current Pulsed Thermography (ECPT) has received extensive attention due to its high sensitive of detectability on surface and subsurface cracks. However, it remains as a difficult challenge in unsupervised detection as to identify defects without knowing any prior knowledge. This paper presents a spatial-time-state features fusion algorithm to obtain fully profile of the defects by directional scanning. The proposed method is intended to conduct features extraction by using independent component analysis (ICA) and automatic features selection embedding genetic algorithm. Finally, the optimal feature of each step is fused to obtain defects reconstruction by applying common orthogonal basis extraction (COBE) method. Experiments have been conducted to validate the study and verify the efficacy of the proposed method on blind defect detection.

  7. In-flight investigations of the unsteady behaviour of the boundary layer with infrared thermography

    International Nuclear Information System (INIS)

    Szewczyk, Mariusz; Smusz, Robert; Kucaba-Pietal, Anna; Rzucidlo, Pawel; De Groot, Klaus; Meyer, Joerg

    2017-01-01

    Infrared thermography (IRT) has been well established in wind tunnel and flight tests for the last decade. Former applications of IRT were focused, in nearly all cases, on steady measurements. In the last years, requirements of unsteady IRT measurements (up to 10 Hz) have been formulated, but the problem of a very slow thermal response of common materials of wind tunnel models or airplane components has to be overcome by finding a surface modification with a fast thermal response (low heat capacity, low thermal conductivity and high thermal diffusivity). Therefore, lab investigations of potential material combinations and flight tests with a ‘low cost’ aircraft, i.e. a glider with a modified wing surface, were conducted. In order to induce unsteady conditions (rapid change of laminar-turbulent boundary layer transition), special maneuvers of a glider during IRT measurements were performed. (paper)

  8. Application of infrared thermography for temperature distributions in fluid-saturated porous media

    DEFF Research Database (Denmark)

    Imran, Muhammad; Nick, Hamid; Schotting, Ruud J.

    2016-01-01

    is achieved with a combination of invasive sensors which are inserted into the medium and non-invasive thermal sensors in which sensors are not inserted to measure temperatures but it works through the detection of infrared radiation emitted from the surface. Thermocouples of relatively thin diameter are used......Infrared thermography has increasingly gained importance because of environmental and technological advancements of this method and is applied in a variety of disciplines related to non-isothermal flow. However, it has not been used so far for quantitative thermal analysis in saturated porous media....... This article suggests infrared thermographic approach to obtain the entire surface temperature distribution(s) in water-saturated porous media. For this purpose, infrared thermal analysis is applied with in situ calibration for a better understanding of the heat transfer processes in porous media. Calibration...

  9. Investigation of non-reciprocal magnon propagation using lock-in thermography

    Science.gov (United States)

    Wid, Olga; Bauer, Jan; Müller, Alexander; Breitenstein, Otwin; Parkin, Stuart S. P.; Schmidt, Georg

    2017-04-01

    We have investigated the unidirectional spin wave heat conveyer effect in a 200 nm thin yttrium iron garnet (YIG) film using lock-in thermography (LIT). This originates from the non-reciprocal propagation of magnons, which leads to an asymmetric heat transport. To excite the spin waves we use two different respective antenna geometries: a coplanar waveguide (CPW) or a ‘microstrip’-like antenna on top of the YIG. By using the CPW and comparing the results for the Damon-Eshbach and the backward volume modes we are able to show that the origin of the asymmetric heat profile are indeed the non-reciprocal spin waves. Using the ‘microstrip’-like geometry we can confirm these results and we can even observe a distinct excitation profile along the antenna due to small field inhomogeneities.

  10. Development of composite calibration standard for quantitative NDE by ultrasound and thermography

    Science.gov (United States)

    Dayal, Vinay; Benedict, Zach G.; Bhatnagar, Nishtha; Harper, Adam G.

    2018-04-01

    Inspection of aircraft components for damage utilizing ultrasonic Non-Destructive Evaluation (NDE) is a time intensive endeavor. Additional time spent during aircraft inspections translates to added cost to the company performing them, and as such, reducing this expenditure is of great importance. There is also great variance in the calibration samples from one entity to another due to a lack of a common calibration set. By characterizing damage types, we can condense the required calibration sets and reduce the time required to perform calibration while also providing procedures for the fabrication of these standard sets. We present here our effort to fabricate composite samples with known defects and quantify the size and location of defects, such as delaminations, and impact damage. Ultrasonic and Thermographic images are digitally enhanced to accurately measure the damage size. Ultrasonic NDE is compared with thermography.

  11. Diagnosis of response and non-response to dry eye treatment using infrared thermography images

    Science.gov (United States)

    Acharya, U. Rajendra; Tan, Jen Hong; Vidya, S.; Yeo, Sharon; Too, Cheah Loon; Lim, Wei Jie Eugene; Chua, Kuang Chua; Tong, Louis

    2014-11-01

    The dry eye treatment outcome depends on the assessment of clinical relevance of the treatment effect. The potential approach to assess the clinical relevance of the treatment is to identify the symptoms responders and non-responders to the given treatments using the responder analysis. In our work, we have performed the responder analysis to assess the clinical relevance effect of the dry eye treatments namely, hot towel, EyeGiene®, and Blephasteam® twice daily and 12 min session of Lipiflow®. Thermography is performed at week 0 (baseline), at weeks 4 and 12 after treatment. The clinical parameters such as, change in the clinical irritations scores, tear break up time (TBUT), corneal staining and Schirmer's symptoms tests values are used to obtain the responders and non-responders groups. We have obtained the infrared thermography images of dry eye symptoms responders and non-responders to the three types of warming treatments. The energy, kurtosis, skewness, mean, standard deviation, and various entropies namely Shannon, Renyi and Kapoor are extracted from responders and non-responders thermograms. The extracted features are ranked based on t-values. These ranked features are fed to the various classifiers to get the highest performance using minimum features. We have used decision tree (DT), K nearest neighbour (KNN), Naves Bayesian (NB) and support vector machine (SVM) to classify the features into responder and non-responder classes. We have obtained an average accuracy of 99.88%, sensitivity of 99.7% and specificity of 100% using KNN classifier using ten-fold cross validation.

  12. Potentialities of infrared thermography to assess damage in bonding between concrete and GFRP

    Directory of Open Access Journals (Sweden)

    M. M. CALDEIRA

    Full Text Available This paper demonstrates the application of the active infrared thermography to detect damage in bonding between concrete and glass fiber reinforced polymer (GFRP. Specimens of concrete and mortar with GFRP externally bonded were prepared and at their interfaces were inserted polystyrene discs to simulate damages. The samples were divided into two groups. In group 1, one sample was correctly bonded by a GFRP plate to the concrete, but in the other three were inserted polystyrene discs which had different diameters to simulate damages in bonding. In group 2, all of the samples contained identical polystyrene discs at their interfaces, but the total thickness of each specimen was different, because the objective was to evaluate the ability of the camera to capture the simulated damage in depth. The experimental procedure was divided into two stages. In the first stage, four types of heating were used to heat samples of group 1: incandescent lamp, kiln, blended lamp and fan heater. Thus, it was possible to detect the damage and to observe its format and length. It was noticed that the infrared images are different depending on the heat source incident on the specimen. Therefore, group 2 was tested only for the more efficient heating (incandescent lamp. In the second stage, the infrared equipment was tested. Some of the parameters that must be inserted in the camera were varied in order to understand their influence on image formation. The results show the effectiveness of infrared thermography to assess adherence in GFRP/concrete interface. In the present work, the best results were obtained when the image is captured towards GFRP/concrete and using incandescent lamp. It was observed that the image and measured temperature suffer significant distortion when a false value was inserted for the parameter emissivity.

  13. Investigating Small-Scale Air–Sea Exchange Processes via Thermography

    Directory of Open Access Journals (Sweden)

    Jakob Kunz

    2018-03-01

    Full Text Available The exchange of trace gases such as carbon dioxide or methane between the atmosphere and the ocean plays a key role for the climate system. However, the investigation of air–sea gas exchange rates lacks fast and accurate measurement techniques that can also be used in the field, e.g., onboard a ship on the ocean. A promising way to overcome this deficiency is to use heat as a proxy tracer for gas transfer. Heat transfer rates across the aqueous boundary layer of the air–water interface can be measured via thermography with unprecedented temporal and spatial resolution in the order of minutes and meters, respectively. Either passive or active measurement schemes can be applied. Passive approaches rely on temperature differences across the water surface, which are caused naturally by radiative and evaporative cooling of the water surface. Active measurement schemes force an artificial heat flux through the aqueous boundary layer by means of heating a patch at the water surface with an appropriate heat source, such as a CO2 laser. The choice of the excitation signal is crucial. It is beneficial to apply periodic heat flux densities with different excitation frequencies. In this way, the air–water interface can be probed for its response in terms of temperature amplitude and phase shift between excitation signal and temperature response. This concept from linear system theory is also well established in the field of non-destructive material testing, where it is known as lock-in thermography. This article gives a short introduction into air–sea gas exchange, before it presents an overview of different thermographic measurement techniques used in wind-wave facilities and at sea starting with early implementations. The article closes with a novel multifrequency excitation scheme for even faster measurements.

  14. Nonlinear ultrasonic stimulated thermography for damage assessment in isotropic fatigued structures

    Science.gov (United States)

    Fierro, Gian Piero Malfense; Calla', Danielle; Ginzburg, Dmitri; Ciampa, Francesco; Meo, Michele

    2017-09-01

    Traditional non-destructive evaluation (NDE) and structural health monitoring (SHM) systems are used to analyse that a structure is free of any harmful damage. However, these techniques still lack sensitivity to detect the presence of material micro-flaws in the form of fatigue damage and often require time-consuming procedures and expensive equipment. This research work presents a novel "nonlinear ultrasonic stimulated thermography" (NUST) method able to overcome some of the limitations of traditional linear ultrasonic/thermography NDE-SHM systems and to provide a reliable, rapid and cost effective estimation of fatigue damage in isotropic materials. Such a hybrid imaging approach combines the high sensitivity of nonlinear acoustic/ultrasonic techniques to detect micro-damage, with local defect frequency selection and infrared imaging. When exciting structures with an optimised frequency, nonlinear elastic waves are observed and higher frictional work at the fatigue damaged area is generated due to clapping and rubbing of the crack faces. This results in heat at cracked location that can be measured using an infrared camera. A Laser Vibrometer (LV) was used to evaluate the extent that individual frequency components contribute to the heating of the damage region by quantifying the out-of-plane velocity associated with the fundamental and second order harmonic responses. It was experimentally demonstrated the relationship between a nonlinear ultrasound parameter (βratio) of the material nonlinear response to the actual temperature rises near the crack. These results demonstrated that heat generation at damaged regions could be amplified by exciting at frequencies that provide nonlinear responses, thus improving the imaging of material damage and the reliability of NUST in a quick and reproducible manner.

  15. Methodology for high-throughput field phenotyping of canopy temperature using airborne thermography

    Directory of Open Access Journals (Sweden)

    David Matthew Deery

    2016-12-01

    Full Text Available Lower canopy temperature (CT, resulting from increased stomatal conductance, has been associated with increased yield in wheat. Historically, CT has been measured with hand-held infrared thermometers. Using the hand-held CT method on large field trials is problematic, mostly because measurements are confounded by temporal weather changes during the time requiredto measure all plots. The hand-held CT method is laborious and yet the resulting heritability low, thereby reducing confidence in selection in large scale breeding endeavours.We have developed a reliable and scalable crop phenotyping method for assessing CT in large field experiments. The method involves airborne thermography from a manned helicopter using a radiometrically-calibrated thermal camera. Thermal image data is acquired from large experiments in the order of seconds, thereby enabling simultaneous measurement of CT on potentially 1,000s of plots. Effects of temporal weather variation when phenotyping large experiments using hand-held infrared thermometers are therefore reduced. The method is designed for cost-effective and large-scale use by the non-technical user and includes custom-developed software for data processing to obtain CT data on a single-plot basis for analysis.Broad-sense heritability was routinely greater than 0.50, and as high as 0.79, for airborne thermography CT measured near anthesis on a wheat experiment comprising 768 plots of size 2 x 6 m. Image analysis based on the frequency distribution of temperature pixels to remove the possible influence of background soil did not improve broad-sense heritability. Total imageacquisition and processing time was ca. 25 min and required only one person (excluding the helicopter pilot. The results indicate the potential to phenotype CT on large populations in genetics studies or for selection within a plant breeding program.

  16. Technical note: Relationship between infrared thermography and heat production in young bulls.

    Science.gov (United States)

    Gomes, R A; Busato, K C; Ladeira, M M; Johnson, K A; Galvão, M C; Rodrigues, A C; Lourençoni, D; Chizzotti, M L

    2016-03-01

    The traditional techniques to measure heat production (HP) are calorimetry (direct and indirect) and comparative slaughter. Both methods are expensive and require extensive amounts of time and infrastructure. Infrared thermography (IRT) could be a faster and less expensive alternative to estimate cattle HP. The objective of this project was to evaluate the use of the IRT technique as an indicator of HP in cattle. A total of 24 bulls (12 Nellore and 12 Black Angus) with initial BW of 380 ± 7 kg were used. Initially, 4 animals of each breed were harvested (baseline animals) and simple regressions were developed for each breed from these baseline animals to estimate the initial chemical composition of the remaining bulls. Eight animals of each breed were fed a silage/concentrate diet for ad libitum intake in individual stalls. On the 25th, 50th, and 75th experimental day, infrared thermal images (Fluke Ti 55ft; Fluke Corporation) were taken of each animal's face to access skin and ocular surface temperatures. A metabolism trial was conducted to estimate the ME intake (MEI). After 84 experimental days, the cattle were harvested and retained energy (RE) and HP were calculated. The data were analyzed using the MIXED and REG procedures of SAS adopting a significance level of 0.05. Angus cattle had a greater daily MEI, HP, and skin and eye temperatures than Nellore. We found significant correlations ( ≤ 0.005) between daily HP and maximum ( = 0.65) and average skin temperatures ( = 0.65) and maximum ( = 0.65) and average ocular surface ( = 0.69) temperatures recorded on d 50. Infrared thermography has potential to be used to evaluate HP in cattle.

  17. Neonatal non-contact respiratory monitoring based on real-time infrared thermography

    Directory of Open Access Journals (Sweden)

    Abbas Abbas K

    2011-10-01

    Full Text Available Abstract Background Monitoring of vital parameters is an important topic in neonatal daily care. Progress in computational intelligence and medical sensors has facilitated the development of smart bedside monitors that can integrate multiple parameters into a single monitoring system. This paper describes non-contact monitoring of neonatal vital signals based on infrared thermography as a new biomedical engineering application. One signal of clinical interest is the spontaneous respiration rate of the neonate. It will be shown that the respiration rate of neonates can be monitored based on analysis of the anterior naris (nostrils temperature profile associated with the inspiration and expiration phases successively. Objective The aim of this study is to develop and investigate a new non-contact respiration monitoring modality for neonatal intensive care unit (NICU using infrared thermography imaging. This development includes subsequent image processing (region of interest (ROI detection and optimization. Moreover, it includes further optimization of this non-contact respiration monitoring to be considered as physiological measurement inside NICU wards. Results Continuous wavelet transformation based on Debauches wavelet function was applied to detect the breathing signal within an image stream. Respiration was successfully monitored based on a 0.3°C to 0.5°C temperature difference between the inspiration and expiration phases. Conclusions Although this method has been applied to adults before, this is the first time it was used in a newborn infant population inside the neonatal intensive care unit (NICU. The promising results suggest to include this technology into advanced NICU monitors.

  18. Soil salinity assessment through satellite thermography for different irrigated and rainfed crops

    Science.gov (United States)

    Ivushkin, Konstantin; Bartholomeus, Harm; Bregt, Arnold K.; Pulatov, Alim; Bui, Elisabeth N.; Wilford, John

    2018-06-01

    The use of canopy thermography is an innovative approach for salinity stress detection in plants. But its applicability for landscape scale studies using satellite sensors is still not well investigated. The aim of this research is to test the satellite thermography soil salinity assessment approach on a study area with different crops, grown both in irrigated and rainfed conditions, to evaluate whether the approach has general applicability. Four study areas in four different states of Australia were selected to give broad representation of different crops cultivated under irrigated and rainfed conditions. The soil salinity map was prepared by the staff of Geoscience Australia and CSIRO Land and Water and it is based on thorough soil sampling together with environmental modelling. Remote sensing data was captured by the Landsat 5 TM satellite. In the analysis we used vegetation indices and brightness temperature as an indicator for canopy temperature. Applying analysis of variance and time series we have investigated the applicability of satellite remote sensing of canopy temperature as an approach of soil salinity assessment for different crops grown under irrigated and rainfed conditions. We concluded that in all cases average canopy temperatures were significantly correlated with soil salinity of the area. This relation is valid for all investigated crops, grown both irrigated and rainfed. Nevertheless, crop type does influence the strength of the relations. In our case cotton shows only minor temperature difference compared to other vegetation classes. The strongest relations between canopy temperature and soil salinity were observed at the moment of a maximum green biomass of the crops which is thus considered to be the best time for application of the approach.

  19. [Diagnosing Low Health and Wood Borer Attacked Trees of Chinese Arborvitae by Using Thermography].

    Science.gov (United States)

    Wang, Fei; Wu, De-jun; Zhai, Guo-feng; Zang, Li-peng

    2015-12-01

    Water and energy metabolism of plants is very important actions in their lives. Although the studies about these actions by using thermography were often reported, seldom were found in detecting the health status of forest trees. In this study, we increase the measurement accuracy and comparability of thermo-images by creating the difference indices. Based on it, we exam the water and energy status in stem of Chinese arborvitae (Platycladus orientalis (L.) Franco) by detecting the variance of far infrared spectrum between sap-wood and heart-wood of the cross-section of felling trees and the cores from an increment borer using thermography. The results indicate that the sap rate between sapwood and heartwood is different as the variance of the vigor of forest trees. Meanwhile, the image temperature of scale leaves from Chinese arborvitae trees with different vigor is also dissimilar. The far infrared spectrum more responds the sap status not the wood percentage in comparing to the area rate between sapwood and heartwood. The image temperature rate can be used in early determining the health status of Chinese arborvitae trees. The wood borers such as Phloeosinus aubei Perris and Semanotus bifasciatus Motschulsky are the pests which usually attack the low health trees, dying trees, wilted trees, felled trees and new cultivated trees. This measuring technique may be an important index to diagnose the health and vigor status after a large number of measurements for Chinese arborvitae trees. Therefore, there is potential to be an important index to check the tree vigor and pest damage status by using this technique. It will be a key in the tending and management of ecological and public Chinese arborvitae forest.

  20. Breast Reconstruction After Mastectomy

    Science.gov (United States)

    ... Cancer Prevention Genetics of Breast & Gynecologic Cancers Breast Cancer Screening Research Breast Reconstruction After Mastectomy On This Page What is breast reconstruction? How do surgeons use implants to reconstruct a woman’s breast? How do surgeons ...

  1. Breast cancer screening

    Science.gov (United States)

    Mammogram - breast cancer screening; Breast exam - breast cancer screening; MRI - breast cancer screening ... is performed to screen women to detect early breast cancer when it is more likely to be cured. ...

  2. Stages of Breast Cancer

    Science.gov (United States)

    ... of Breast & Gynecologic Cancers Breast Cancer Screening Research Breast Cancer Treatment (PDQ®)–Patient Version General Information About Breast Cancer Go to Health Professional Version Key Points Breast ...

  3. Breast Cancer Prevention

    Science.gov (United States)

    ... of Breast & Gynecologic Cancers Breast Cancer Screening Research Breast Cancer Prevention (PDQ®)–Patient Version What is prevention? Go ... from starting. Risk-reducing surgery . General Information About Breast Cancer Key Points Breast cancer is a disease in ...

  4. Breast Cancer Treatment

    Science.gov (United States)

    ... of Breast & Gynecologic Cancers Breast Cancer Screening Research Breast Cancer Treatment (PDQ®)–Patient Version General Information About Breast Cancer Go to Health Professional Version Key Points Breast ...

  5. Primary radiation therapy for early breast cancer: the experience at the joint center for radiation therapy

    International Nuclear Information System (INIS)

    Harris, J.R.; Botnick, L.; Bloomer, W.D.; Chaffey, J.T.; Hellman, S.

    1981-01-01

    The results of primary radiation therapy in 176 consecutive patients with clinical State I and II carcinoma of the breast were reviewed. Median follow-up time was 47 months. The overall breast relapse rate was 7%. Patients undergoing interstitial implantation had a significantly lower breast relapse rate (1%) than patients not undergoing implantation (11%). Breast relapse was more common in patients undergoing incisional or needle biopsy (17%), compared to patients treated after excisional biopsy (5%). In patients undergoing excisional biopsy, but not interstitial implantation, breast relapse was related to external beam dose. Twelve percent of the patients who received less than 1600 ret dose relapsed in the breast, compared to none of the 19 patients who received more than 1700 ret dose. These results imply that supplemental irradiation to the primary tumor area is required following excisional biopsy of a primary breast cancer when 4500-5000 rad is delivered to the entire breast

  6. Infrared thermography, a new method for detection of brown adipose tissue activity after a meal in humans

    Science.gov (United States)

    Habek, Nikola; Kordić, Milan; Jurenec, Franjo; Dugandžić, Aleksandra

    2018-03-01

    The activation of brown adipose tissue (BAT) after cold exposure leads to heat production. However, the activation of BAT activity after a meal as part of diet induced thermogenesis is still controversial. A possible reason is that measuring BAT activity by positron emission tomography-computed tomography (PET CT) via accumulation of radiotracer fludeoxyglucose (18F-FDG), which competes with an increase in glucose concentration after a meal, fails as the method of choice. In this study, activity of BAT was determined by infrared thermography. Activation of BAT 30 min after a meal increases glucose consumption, decreases plasma glucose concentration, and leads to changes of body temperature (diet-induced thermogenesis). Detecting pathophysiological changes in BAT activity after a meal by infrared thermography, a non-invasive more sensitive method, will be of great importance for people with increased body weight and diabetes mellitus type 2.

  7. Breast cancer

    OpenAIRE

    Gablerová, Pavlína

    2010-01-01

    In this work the topic of breast cancer treated more generally and mainly focused on risk factors for the development. The theoretical part describes the general knowledge about breast cancer as a stage or treatment. The practical part is to have clarified the risk factors that have some bearing on the diagnosis of breast cancer. What level are involved in the probability of occurrence? Can we eliminate them? As a comparison of risk factors examined in the Czech Republic, England, Australia a...

  8. Assessing honeybee and wasp thermoregulation and energetics-New insights by combination of flow-through respirometry with infrared thermography

    Energy Technology Data Exchange (ETDEWEB)

    Stabentheiner, Anton, E-mail: anton.stabentheiner@uni-graz.at [Institut fuer Zoologie, Karl-Franzens-Universitaet Graz, Universitaetsplatz 2, A-8010 Graz (Austria); Kovac, Helmut, E-mail: he.kovac@uni-graz.at [Institut fuer Zoologie, Karl-Franzens-Universitaet Graz, Universitaetsplatz 2, A-8010 Graz (Austria); Hetz, Stefan K. [Department of Animal Physiology/Systems Neurobiology and Neural Computation, Philippstrasse 13-Leonor Michaelis Haus, Humboldt-Universitaet zu Berlin, 10115 Berlin (Germany); Kaefer, Helmut; Stabentheiner, Gabriel [Institut fuer Zoologie, Karl-Franzens-Universitaet Graz, Universitaetsplatz 2, A-8010 Graz (Austria)

    2012-04-20

    Highlights: Black-Right-Pointing-Pointer We demonstrate the benefits of a combined use of infrared thermography with respiratory measurements in insect ecophysiological research. Black-Right-Pointing-Pointer Infrared thermography enables repeated investigation of behaviour and thermoregulation without behavioural impairment. Black-Right-Pointing-Pointer Comparison with respirometry brings new insights into the mechanisms of energetic optimisation of bee and wasp foraging. Black-Right-Pointing-Pointer Combination of methods improves interpretation of respiratory traces in determinations of insect critical thermal limits. - Abstract: Endothermic insects like honeybees and some wasps have to cope with an enormous heat loss during foraging because of their small body size in comparison to endotherms like mammals and birds. The enormous costs of thermoregulation call for optimisation. Honeybees and wasps differ in their critical thermal maximum, which enables the bees to kill the wasps by heat. We here demonstrate the benefits of a combined use of body temperature measurement with infrared thermography, and respiratory measurements of energy turnover (O{sub 2} consumption or CO{sub 2} production via flow-through respirometry) to answer questions of insect ecophysiological research, and we describe calibrations to receive accurate results. To assess the question of what foraging honeybees optimise, their body temperature was compared with their energy turnover. Honeybees foraging from an artificial flower with unlimited sucrose flow increased body surface temperature and energy turnover with profitability of foraging (sucrose content of the food; 0.5 or 1.5 mol/L). Costs of thermoregulation, however, were rather independent of ambient temperature (13-30 Degree-Sign C). External heat gain by solar radiation was used to increase body temperature. This optimised foraging energetics by increasing suction speed. In determinations of insect respiratory critical thermal limits

  9. Measurement of Three-Dimensional Anisotropic Thermal Diffusivities for Carbon Fiber-Reinforced Plastics Using Lock-In Thermography

    Science.gov (United States)

    Ishizaki, Takuya; Nagano, Hosei

    2015-11-01

    A new measurement technique to measure the in-plane thermal diffusivity, the distribution of in-plane anisotropy, and the out-of-plane thermal diffusivity has been developed to evaluate the thermal conductivity of anisotropic materials such as carbon fiber-reinforced plastics (CFRPs). The measurements were conducted by using a laser-spot-periodic-heating method. The temperature of the sample is detected by using lock-in thermography. Thermography can analyze the phase difference between the periodic heat input and the temperature response of the sample. Two kinds of samples, unidirectional (UD) and cross-ply (CP) pitch-based CFRPs, were fabricated and tested in an atmospheric condition. All carbon fibers of the UD sample run in one direction [90°]. The carbon fibers of the CP sample run in two directions [0°/90°]. It is found that, by using lock-in thermography, it is able to visualize the thermal anisotropy and calculate the angular dependence of the in-plane thermal diffusivity of the CFRPs. The out-of-plane thermal diffusivity of CFRPs was also measured by analyzing the frequency dependence of the phase difference.

  10. Active thermography and post-processing image enhancement for recovering of abraded and paint-covered alphanumeric identification marks

    Science.gov (United States)

    Montanini, R.; Quattrocchi, A.; Piccolo, S. A.

    2016-09-01

    Alphanumeric marking is a common technique employed in industrial applications for identification of products. However, the realised mark can undergo deterioration, either by extensive use or voluntary deletion (e.g. removal of identification numbers of weapons or vehicles). For recovery of the lost data many destructive or non-destructive techniques have been endeavoured so far, which however present several restrictions. In this paper, active infrared thermography has been exploited for the first time in order to assess its effectiveness in restoring paint covered and abraded labels made by means of different manufacturing processes (laser, dot peen, impact, cold press and scribe). Optical excitation of the target surface has been achieved using pulse (PT), lock-in (LT) and step heating (SHT) thermography. Raw infrared images were analysed with a dedicated image processing software originally developed in Matlab™, exploiting several methods, which include thermographic signal reconstruction (TSR), guided filtering (GF), block guided filtering (BGF) and logarithmic transformation (LN). Proper image processing of the raw infrared images resulted in superior contrast and enhanced readability. In particular, for deeply abraded marks, good outcomes have been obtained by application of logarithmic transformation to raw PT images and block guided filtering to raw phase LT images. With PT and LT it was relatively easy to recover labels covered by paint, with the latter one providing better thermal contrast for all the examined targets. Step heating thermography never led to adequate label identification instead.

  11. Potential application of thermography (IRT in animal production and for animal welfare. A case report of working dogs

    Directory of Open Access Journals (Sweden)

    Veronica Redaelli

    2014-06-01

    Full Text Available INTRODUCTION. The authors describe the thermography technique in animal production and in veterinary medicine applications. The thermographic technique lends itself to countless applications in biology, thanks to its characteristics of versatility, lack of invasiveness and high sensitivity. Probably the major limitation to most important aspects for its application in the animal lies in the ease of use and in its extreme sensitivity. Materials and methods. This review provides an overview of the possible applications of the technique of thermo visual inspection, but it is clear that every phenomenon connected to temperature variations can be identified with this technique. Then the operator has to identify the best experimental context to obtain as much information as possible, concerning the physiopathological problems considered. Furthermore, we reported an experimental study about the thermography (IRT as a noninvasive technique to assess the state of wellbeing in working dogs. RESULTS. The first results showed the relationship between superficial temperatures and scores obtained by the animal during the behavioral test. This result suggests an interesting application of infrared thermography (IRT to measure the state of wellbeing of animals in a noninvasive way.

  12. Qualitative study of sexual functioning in couples with erectile dysfunction: prospective evaluation of the thermography diagnostic system.

    Science.gov (United States)

    Ng, Wan Kee; Ng, Yin Kwee; Tan, Yung Khan

    2009-01-01

    To evaluate the prospective use of the thermography diagnostic system in assessing sexual function in patients with erectile dysfunction (ED). Thermographs were taken on 14 subjects in a clinical trial conducted at Tan Tock Seng Hospital. After a thorough clinical interview with a standardized questionnaire, patients were scanned for baseline temperature profile before being given an oral dose of sildenafil 100 mg. Subjects were scanned again in the same setting an hour later. If so desired, subjects were given visual stimulation and were allowed minimum direct stimulation, excluding the penis, to elicit erection. Temperature profiles were analyzed using the thermography analysis software in the VarioCAM camera. Three representative cases are presented to illustrate the potential for using the Infrared thermography (IR) diagnostic system in differentiating psychogenic ED. IR was able to capture a significant difference in blood flow to the corpus cavernosum. Subjects with psychogenic ED have higher surface temperatures (34.3 degrees C +/- 0.71 in the flaccid state and 35.3 degrees C +/- 0.2 during erection) compared to subjects with organic ED (33.64 degrees C +/- 0.4 in flaccid and 33.55 degrees C +/- 0.91 during erection). The difference in surface temperature between flaccid and erected states in subjects with organic ED was not significant. The proposed diagnostic test based on IR has tremendous clinical potential in differentiating psychogenic ED from organic ED. IR could potentially be a portable, noninvasive and convenient adjunct in the diagnosis and management of ED.

  13. High-speed infrared thermography for the measurement of microscopic boiling parameters on micro- and nano-structured surfaces

    International Nuclear Information System (INIS)

    Park, Youngjae; Kim, Hyungdae; Kim, Hyungmo; Kim, Joonwon

    2014-01-01

    Micro- and nano-scale structures on boiling surfaces can enhance nucleate boiling heat transfer coefficient (HTC) and critical heat flux (CHF). A few studies were conducted to explain the enhancements of HTC and CHF using the microscopic boiling parameters. Quantitative measurements of microscopic boiling parameters are needed to understand the physical mechanism of the boiling heat transfer augmentation on structured surfaces. However, there is no existing experimental techniques to conveniently measure the boiling parameters on the structured surfaces because of the small (thermography to visualize liquid-vapor phase distribution during nucleate pool boiling on micro- and nano-structured surfaces. The visualization results are analyzed to obtain the microscopic boiling parameters. Finally, quantitative microscopic boiling parameters are used to interpret the enhancement of HTC and CHF. In this study, liquid-vapor phase distributions of each surface were clearly visualized by IR thermography during the nucleate boiling phenomena. From the visualization results, following microscopic boiling parameters were quantitatively measured by image processing. - Number density of dry patch, NDP IR thermography technique was demonstrated by nucleate pool boiling experiments with M- and N surfaces. The enhancement of HTC and CHF could be explained by microscopic boiling parameters

  14. Interim advice concerning the early detection of breast cancer. Interim-advies inzake de vroegtijdige opsporing van borstkanker

    Energy Technology Data Exchange (ETDEWEB)

    1982-01-01

    The incidence of breast cancer in the Netherlands and the methods of diagnosis and treatment are outlined. A systematic screening of the total female population would result in a number of breast cancers being found at a relatively early stage. The advantages and disadvantages of five methods of screening are discussed: breast self-examination by women, palpation by doctor or para-medical personnel, mammography, ultrasound and thermography. It is concluded that mammography currently appears to be the best method. The risk that the X-rays might cause cancer is negligible. Two large screening projects in the Netherlands are described and the preliminary results discussed. In the appendices, a number of aspects such as the current projects in the Netherlands, the risks of ionizing radiation, and the attitudes and response of women invited for screening, are elaborated upon. A discussion session between an advisory committee and a number of Dutch and foreign experts is also presented (in English).

  15. Radiation-resistance assessment of IR fibres for ITER thermography diagnostic system

    International Nuclear Information System (INIS)

    Brichard, B.; Ierschot, S. van; Ooms, H.; Berghmans, F.; Reichle, R.; Pocheau, C.; Decreton, M.

    2006-01-01

    The actively cooled target plates in the divertor of ITER will be subjected to high thermal fluxes (∼ 10 MW/m 2 ). These target plates are compound structures of an armour material at the surface - either carbon fibre reinforced carbon (CFC) or tungsten - and a water cooled CuCrZr structure inside or below. The thermal limit of the interface between the two materials must not exceed 550 o C. Therefore, the temperature must be carefully monitored to prevent structural damages of the divertor plates. Non contact measurements of the temperature offer the advantage to avoid weakening of the cooling plate structure which is already quite complex to manufacture. Infrared thermography of the target surface is therefore considered as a possible solution. Recently a diagnostic concept for spectrally resolved ITER divertor thermography using optical fibres has been proposed by CEA-Cadarache. However, the divertor region will have to face high-radiation flux and the radiation-resistance of InfraRed (IR)-fibres must be evaluated. In collaboration with CEA-Cadarache, an irradiation program has been started at SCK-CEN (Mol, Belgium) with the aim to measure the radiation-induced absorption of different IR fibre candidates operating in the 1-5 μm range. We selected various commercially available IR technologies: ZrF 4 , Hollow-Waveguide, Sapphire and Chalcogenide. For wavelengths below 2 μm we also tested low-OH silica fibres. We carried out a gamma irradiation at a maximum dose-rate of 0.42 Gy/s up to a total dose of about 5000 Gy. We showed that the optical transmission of ZrF 4 fibres strongly decreased under gamma radiation, primarily for wavelengths below 2 μm. In this type of fibre typical optical losses can reach 50 % at 5000 Gy around 3 μm. Nevertheless, the optical transmission can be significantly recovered by performing a thermal annealing treatment at a temperature of 100 o C. We also irradiated a Silver-coated hollow waveguide fibre at the same dose-rate but up

  16. Breast asymmetry and predisposition to breast cancer

    OpenAIRE

    Scutt, Diane; Lancaster, Gillian A; Manning, John T

    2006-01-01

    INTRODUCTION: It has been shown in our previous work that breast asymmetry is related to several of the known risk factors for breast cancer, and that patients with diagnosed breast cancer have more breast volume asymmetry, as measured from mammograms, than age-matched healthy women. METHODS: In the present study, we compared the breast asymmetry of women who were free of breast disease at time of mammography, but who had subsequently developed breast cancer, with that of age-matched healthy ...

  17. 3D thermography for improving temperature measurements in thermal vacuum testing

    Science.gov (United States)

    Robinson, D. W.; Simpson, R.; Parian, J. A.; Cozzani, A.; Casarosa, G.; Sablerolle, S.; Ertel, H.

    2017-09-01

    The application of thermography to thermal vacuum (TV) testing of spacecrafts is becoming a vital additional tool in the mapping of structures during thermal cycles and thermal balance (TB) testing. Many of the customers at the European Space Agency (ESA) test centre, European Space Research and Technology Centre (ESTEC), The Netherlands, now make use of a thermal camera during TB-TV campaigns. This complements the use of embedded thermocouples on the structure, providing the prospect of monitoring temperatures at high resolution and high frequency. For simple flat structures with a well-defined emissivity, it is possible to determine the surface temperatures with reasonable confidence. However, for most real spacecraft and sub-systems, the complexity of the structure's shape and its test environment creates inter-reflections from external structures. This and the additional complication of angular and spectral variations of the spacecraft surface emissivity make the interpretation of the radiation detected by a thermal camera more difficult in terms of determining a validated temperature with high confidence and well-defined uncertainty. One solution to this problem is: to map the geometry of the test specimen and thermal test environment; to model the surface temperatures and emissivity variations of the structures and materials; and to use this model to correct the apparent temperatures recorded by the thermal camera. This approach has been used by a team from NPL (National Physical Laboratory), Psi-tran, and PhotoCore, working with ESA, to develop a 3D thermography system to provide a means to validate thermal camera temperatures, based on a combination of thermal imaging photogrammetry and ray-tracing scene modeling. The system has been tested at ESTEC in ambient conditions with a dummy spacecraft structure containing a representative set of surface temperatures, shapes, and spacecraft materials, and with hot external sources and a high power lamp as a sun

  18. Breast cancer

    International Nuclear Information System (INIS)

    Tokunaga, Masayoshi

    1992-01-01

    More than 20-year follow-up of A-bomb survivors in Hiroshima and Nagasaki has a crucial role in determining the relationship of radiation to the occurrence of breast cancer. In 1967, Wanebo et al have first reported 27 cases of breast cancer during the period 1950-1966 among the Adult Health Study population of A-bomb survivors. Since then, follow-up surveys for breast cancer have been made using the Life Span Study (LSS) cohort, and the incidence of breast cancer has increased year by year; that is breast cancer was identified in 231 cases by the first LSS series (1950-1969), 360 cases by the second LSS series (1950-1974), 564 cases by the third LSS series (1950-1980), and 816 cases in the fourth LSS series (1950-1085). The third LSS series have revealed a high risk for radiation-induced breast cancer in women aged 10 or less at the time of exposure (ATE). Both relative and absolute risks are found to be decreased with increasing ages ATE. Based on the above-mentioned findings and other studies on persons exposed medical radiation, radiation-induced breast cancer is characterized by the following: (1) the incidence of breast cancer is linearly increased with increasing radiation doses; (2) both relative and absolute risks for breast cancer are high in younger persons ATE; (3) age distribution of breast cancer in proximally exposed A-bomb survivors is the same as that in both distally A-bomb survivors and non-exposed persons, and there is no difference in histology between the former and latter groups. Thus, immature mammary gland cells before the age of puberty are found to be most radiosensitive. (N.K.)

  19. Chapter Twelve

    African Journals Online (AJOL)

    User

    okada na obere jenareto ai passi mai nebo·. 17 ... Oluchukwu Micro-Finance Bank gbasara aka inyere ndi 10. Mmadu aka n'uzo di .... Nigeria· This in no small measure has been helping unemployed people, graduates ... Even in the transport sector people have been empowered to be self reliant· This could be seen in the ...

  20. A study of mammographic appearance of the breast disease

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Kil Ho; Jung, Kyung Hee; Hwang, Mi Soo; Chang, Jae Chun; Kim, Myung Se; Shim, Min Chul; Min, Hyun Sik [College of Medicine, Yeung Nam University, Gyeongsan (Korea, Republic of)

    1985-08-15

    The history of the radiological examination of the breast has been long, and recently the methods for examining the breast are variable: mammography, thermography, xeroradiography, ultrasonography, water-path sonography, transillumination, mammary C.T., M.R imaging, infra-red scanning, nuclear medicine, and galactography. Most of these methods were not proven or have not been satisfied on their clinical testing but conventional mammography has been the gold standard for diagnosis of the breast cancer and no other method has reached its effectiveness. The authors performed mammography in 488 patients with breast abnormalities who had visited to Yeung Nam University hospital from May, 1983 to December, 1984. And we analyzed the mammographic findings and diagnostic accuracy in pathologically confirmed 53 cases by operations or biopsies. The results are as follows: 1. Among 16 cases of breast malignancies (1) the most prevalent age group is 6th decade (37.5%), followed by 5th decade (31.3%), (2) the most common pathologic type is ductal carcinoma (93.75%), (3) the masses are larger than 2cm in 8 cases, smaller than 2cm in 5 cases, and no visible mass is observed in 3 cases. 2. Among 37 cases of benign breast diseases, (1) the most prevalent age group is 4th and 5th decades (each 11 cases), and followed by 3rd decade (8 cases), (2) the most common disease is benign tumor (17 cases), followed by fibrocystic dysplasia (13 cases), and inflammating disease (7 cases), (3) radiologically visible masses are observed in 16 cases and the masses are smaller than 2cm in 11 cases. 3. The diagnostic accuracy of mammography compared with that of pathology, (1) in malignancy, the accuracy rate is 75% (12/16 cases), and 87% (32/37 cases) in benign diseases, (2) average accuracy rate is 81% (44/53 cases)

  1. A study of mammographic appearance of the breast disease

    International Nuclear Information System (INIS)

    Cho, Kil Ho; Jung, Kyung Hee; Hwang, Mi Soo; Chang, Jae Chun; Kim, Myung Se; Shim, Min Chul; Min, Hyun Sik

    1985-01-01

    The history of the radiological examination of the breast has been long, and recently the methods for examining the breast are variable: mammography, thermography, xeroradiography, ultrasonography, water-path sonography, transillumination, mammary C.T., M.R imaging, infra-red scanning, nuclear medicine, and galactography. Most of these methods were not proven or have not been satisfied on their clinical testing but conventional mammography has been the gold standard for diagnosis of the breast cancer and no other method has reached its effectiveness. The authors performed mammography in 488 patients with breast abnormalities who had visited to Yeung Nam University hospital from May, 1983 to December, 1984. And we analyzed the mammographic findings and diagnostic accuracy in pathologically confirmed 53 cases by operations or biopsies. The results are as follows: 1. Among 16 cases of breast malignancies (1) the most prevalent age group is 6th decade (37.5%), followed by 5th decade (31.3%), (2) the most common pathologic type is ductal carcinoma (93.75%), (3) the masses are larger than 2cm in 8 cases, smaller than 2cm in 5 cases, and no visible mass is observed in 3 cases. 2. Among 37 cases of benign breast diseases, (1) the most prevalent age group is 4th and 5th decades (each 11 cases), and followed by 3rd decade (8 cases), (2) the most common disease is benign tumor (17 cases), followed by fibrocystic dysplasia (13 cases), and inflammating disease (7 cases), (3) radiologically visible masses are observed in 16 cases and the masses are smaller than 2cm in 11 cases. 3. The diagnostic accuracy of mammography compared with that of pathology, (1) in malignancy, the accuracy rate is 75% (12/16 cases), and 87% (32/37 cases) in benign diseases, (2) average accuracy rate is 81% (44/53 cases)

  2. IR thermography for the assessment of the thermal conductivity of aluminum alloys

    Science.gov (United States)

    Nazarov, S.; Rossi, S.; Bison, P.; Calliari, I.

    2017-05-01

    Aluminium alloys are here considered as a structural material for aerospace applications, guaranteeing lightness and strength at the same time. As aluminium alone is not particularly performing from a mechanical point of view, in this experimental solution it is produced as an alloy with Lithium added at 6 % in weight. To increase furtherly the strength of the material, two new alloys are produced by adding 0.5 % in weight of the rare earth elements Neodymium (Nd) and Yttrium (Y). The improvement of the mechanical properties is measured by means of hardness tests. At the same time the thermophysical properties are measured as well, at various temperature, from 80 °C to 500 °C. Thermal diffusivity is measured by Laser Flash equipment in vacuum. One possible drawback of the Al-Li alloy produced at so high percentage of Li (6 %) is an essential anisotropy that is evaluated by IR thermography thank to its imaging properties that allows to measure simultaneously both the in-plane and through-depth thermal diffusivity.

  3. Measurement of wetted area fraction in subcooled pool boiling of water using infrared thermography

    International Nuclear Information System (INIS)

    Kim, Hyungdae; Park, Youngjae; Buongiorno, Jacopo

    2013-01-01

    The wetted area fraction in subcooled pool boiling of water at atmospheric pressure is measured using the DEPIcT (DEtection of Phase by Infrared Thermography) technique. DEPIcT exploits the contrast in infrared (IR) light emissions between wet and dry areas on the surface of an IR-transparent heater to visualize the instantaneous distribution of the liquid and gas phases in contact with the heater surface. In this paper time-averaged wetted area fraction data in nucleate boiling are reported as functions of heat flux (from 30% up to 100% of the Critical Heat Flux) and subcooling (ΔT sub = 0, 5, 10, 30 and 50 °C). The results show that the wetted area fraction monotonically decreases with increasing heat flux and increases with increasing subcooling: both trends are expected. The range of time-averaged wetted area fractions is from 90%, at low heat flux and high subcooling, to 50% at high heat flux (right before CHF) and low subcooling. It is also shown that the dry areas are periodically rewetted by liquid sloshing on the surface at any subcooling and heat flux; however, the dry areas expand irreversibly at CHF

  4. Particle image velocimetry and infrared thermography in a levitated droplet with nanosilica suspensions

    Energy Technology Data Exchange (ETDEWEB)

    Saha, Abhishek; Kumar, Ranganathan [University of Central Florida, Department of Mechanical Materials and Aerospace Engineering, Orlando, FL (United States); Basu, Saptarshi [Indian Institute of Science, Department of Mechanical Engineering, Bangalore (India)

    2012-03-15

    Preferential accumulation and agglomeration kinetics of nanoparticles suspended in an acoustically levitated water droplet under radiative heating has been studied. Particle image velocimetry performed to map the internal flow field shows a single cell recirculation with increasing strength for decreasing viscosities. Infrared thermography and high speed imaging show details of the heating process for various concentrations of nanosilica droplets. Initial stage of heating is marked by fast vaporization of liquid and sharp temperature rise. Following this stage, aggregation of nanoparticles is seen resulting in various structure formations. At low concentrations, a bowl structure of the droplet is dominant, maintained at a constant temperature. At high concentrations, viscosity of the solution increases, leading to rotation about the levitator axis due to the dominance of centrifugal motion. Such complex fluid motion inside the droplet due to acoustic streaming eventually results in the formation of a ring structure. This horizontal ring eventually reorients itself due to an imbalance of acoustic forces on the ring, exposing larger area for laser absorption and subsequent sharp temperature rise. (orig.)

  5. AN EVALUATION OF INFRARED THERMOGRAPHY FOR DETECTION OF BUMBLEFOOT (PODODERMATITIS) IN PENGUINS.

    Science.gov (United States)

    Duncan, Ann E; Torgerson-White, Lauri L; Allard, Stephanie M; Schneider, Tom

    2016-06-01

    The objective of this study was to evaluate infrared thermography as a noninvasive screening tool for detection of pododermatitis during the developing and active stages of disease in three species of penguins: king penguin (Aptenodytes patagonicus) , macaroni penguin (Eudyptes chrysolophus), and rockhopper penguin (Eudyptes chrysocome). In total, 67 penguins were examined every 3 mo over a 15-mo period. At each exam, bumblefoot lesions were characterized and measured, and a timed series of thermal images were collected over a 4-min period. Three different methods were compared for analysis of thermograms. Feet with active lesions that compromise the surface of the foot were compared to feet with inactive lesions and no lesions. The hypothesis was that feet with active lesions would have warmer surface temperatures than the other conditions. Analysis of the data showed that although feet with active bumblefoot lesions are warmer than feet with inactive or no lesions, the variability seen in each individual penguin from one exam day to the next and the overlap seen between temperatures from each condition made thermal imaging an unreliable tool for detection of bumblefoot in the species studied.

  6. Precise Temperature Mapping of GaN-Based LEDs by Quantitative Infrared Micro-Thermography

    Directory of Open Access Journals (Sweden)

    Geon Hee Kim

    2012-04-01

    Full Text Available A method of measuring the precise temperature distribution of GaN-based light-emitting diodes (LEDs by quantitative infrared micro-thermography is reported. To reduce the calibration error, the same measuring conditions were used for both calibration and thermal imaging; calibration was conducted on a highly emissive black-painted area on a dummy sapphire wafer loaded near the LED wafer on a thermoelectric cooler mount. We used infrared thermal radiation images of the black-painted area on the dummy wafer and an unbiased LED wafer at two different temperatures to determine the factors that degrade the accuracy of temperature measurement, i.e., the non-uniform response of the instrument, superimposed offset radiation, reflected radiation, and emissivity map of the LED surface. By correcting these factors from the measured infrared thermal radiation images of biased LEDs, we determined a precise absolute temperature image. Consequently, we could observe from where the local self-heat emerges and how it distributes on the emitting area of the LEDs. The experimental results demonstrated that highly localized self-heating and a remarkable temperature gradient, which are detrimental to LED performance and reliability, arise near the p-contact edge of the LED surface at high injection levels owing to the current crowding effect.

  7. An investigation of noise performance in optical lock-in thermography

    Science.gov (United States)

    Rajic, Nik; Antolis, Cedric

    2017-12-01

    An investigation into the noise performance of optical lock-in thermography (OLT) is described. The study aims to clarify the influence of infrared detector type and key inspection parameters such as illumination strength and lock-in duration on the quality of OLT amplitude and phase imagery. The study compares the performance of a state-of-the-art cooled photon detector with several lower-cost microbolometers. The results reveal a significant noise performance advantage to the photon detector. Under certain inspection regimes the advantage with respect to phase image quality is disproportionately high relative to detector sensitivities. This is shown to result from an explicit dependence in the phase signal variance on the ratio between the signal amplitude and the detector sensitivity. While this finding supports the preferred use of photon detectors for OLT inspections, it does not exclude microbolometers from a useful role. In cases where the significantly lower capital cost and improved practicality of microbolometers provide an advantage it is shown that performance shortfalls can be overcome with a relatively small factorial increase in optical illumination intensity.

  8. Characterization of multi-layered impact damage in polymer matrix composites using lateral thermography

    Science.gov (United States)

    Whitlow, Travis; Sathish, Shamachary

    2017-02-01

    Polymer matrix composites (PMCs) are increasingly being integrated into aircraft structures. However, these components are susceptible to impact related delamination, which, on aircrafts, can occur due to a number of reasons during aircraft use and maintenance. Quantifying impact damage is an important aspect for life-management of aircraft and requires in-depth knowledge of the damage zone on a ply-by-ply level. Traditionally, immersion ultrasound has provided relative high resolution images of impact damage. Ultrasonic time-of-flight data can be used to determine the front surface delamination depth and an approximation of the delaminated area. However, such inspections require the material to be immersed in water and can be time consuming. The objective of this work is to develop a quick and robust methodology to non-destructively characterize multi-layered impact damage using lateral thermography. Initial results suggest lateral heat flow is sensitive to the depth of impact damage. The anticipated outcome of this project is to estimate the extent of through-thickness impact damage. Initial results are shown and future efforts are discussed.

  9. Precise determination of the heat delivery during in vivo magnetic nanoparticle hyperthermia with infrared thermography

    Science.gov (United States)

    Rodrigues, Harley F.; Capistrano, Gustavo; Mello, Francyelli M.; Zufelato, Nicholas; Silveira-Lacerda, Elisângela; Bakuzis, Andris F.

    2017-05-01

    Non-invasive and real-time monitoring of the heat delivery during magnetic nanoparticle hyperthermia (MNH) is of fundamental importance to predict clinical outcomes for cancer treatment. Infrared thermography (IRT) can determine the surface temperature due to three-dimensional heat delivery inside a subcutaneous tumor, an argument that is supported by numerical simulations. However, for precise temperature determination, it is of crucial relevance to use a correct experimental configuration. This work reports an MNH study using a sarcoma 180 murine tumor containing 3.9 mg of intratumorally injected manganese-ferrite nanoparticles. MNH was performed at low field amplitude and non-uniform field configuration. Five 30 min in vivo magnetic hyperthermia experiments were performed, monitoring the surface temperature with a fiber optical sensor and thermal camera at distinct angles with respect to the animal’s surface. The results indicate that temperature errors as large as 7~\\circ C can occur if the experiment is not properly designed. A new IRT error model is found to explain the data. More importantly, we show how to precisely monitor temperature with IRT during hyperthermia, which could positively impact heat dosimetry and clinical planning.

  10. Soft, thin skin-mounted power management systems and their use in wireless thermography.

    Science.gov (United States)

    Lee, Jung Woo; Xu, Renxiao; Lee, Seungmin; Jang, Kyung-In; Yang, Yichen; Banks, Anthony; Yu, Ki Jun; Kim, Jeonghyun; Xu, Sheng; Ma, Siyi; Jang, Sung Woo; Won, Phillip; Li, Yuhang; Kim, Bong Hoon; Choe, Jo Young; Huh, Soojeong; Kwon, Yong Ho; Huang, Yonggang; Paik, Ungyu; Rogers, John A

    2016-05-31

    Power supply represents a critical challenge in the development of body-integrated electronic technologies. Although recent research establishes an impressive variety of options in energy storage (batteries and supercapacitors) and generation (triboelectric, piezoelectric, thermoelectric, and photovoltaic devices), the modest electrical performance and/or the absence of soft, biocompatible mechanical properties limit their practical use. The results presented here form the basis of soft, skin-compatible means for efficient photovoltaic generation and high-capacity storage of electrical power using dual-junction, compound semiconductor solar cells and chip-scale, rechargeable lithium-ion batteries, respectively. Miniaturized components, deformable interconnects, optimized array layouts, and dual-composition elastomer substrates, superstrates, and encapsulation layers represent key features. Systematic studies of the materials and mechanics identify optimized designs, including unusual configurations that exploit a folded, multilayer construct to improve the functional density without adversely affecting the soft, stretchable characteristics. System-level examples exploit such technologies in fully wireless sensors for precision skin thermography, with capabilities in continuous data logging and local processing, validated through demonstrations on volunteer subjects in various realistic scenarios.

  11. Infra-red thermography for high throughput field phenotyping in Solanum tuberosum.

    Directory of Open Access Journals (Sweden)

    Ankush Prashar

    Full Text Available The rapid development of genomic technology has made high throughput genotyping widely accessible but the associated high throughput phenotyping is now the major limiting factor in genetic analysis of traits. This paper evaluates the use of thermal imaging for the high throughput field phenotyping of Solanum tuberosum for differences in stomatal behaviour. A large multi-replicated trial of a potato mapping population was used to investigate the consistency in genotypic rankings across different trials and across measurements made at different times of day and on different days. The results confirmed a high degree of consistency between the genotypic rankings based on relative canopy temperature on different occasions. Genotype discrimination was enhanced both through normalising data by expressing genotype temperatures as differences from image means and through the enhanced replication obtained by using overlapping images. A Monte Carlo simulation approach was used to confirm the magnitude of genotypic differences that it is possible to discriminate. The results showed a clear negative association between canopy temperature and final tuber yield for this population, when grown under ample moisture supply. We have therefore established infrared thermography as an easy, rapid and non-destructive screening method for evaluating large population trials for genetic analysis. We also envisage this approach as having great potential for evaluating plant response to stress under field conditions.

  12. Characterizing convective heat transfer using infrared thermography and the heated-thin-foil technique

    International Nuclear Information System (INIS)

    Stafford, Jason; Walsh, Ed; Egan, Vanessa

    2009-01-01

    Convective heat transfer, due to axial flow fans impinging air onto a heated flat plate, is investigated with infrared thermography to assess the heated-thin-foil technique commonly used to quantify two-dimensional heat transfer performance. Flow conditions generating complex thermal profiles have been considered in the analysis to account for dominant sources of error in the technique. Uncertainties were obtained in the measured variables and the influences on the resultant heat transfer data are outlined. Correction methods to accurately account for secondary heat transfer mechanisms were developed and results show that as convective heat transfer coefficients and length scales decrease, the importance of accounting for errors increases. Combined with flow patterns that produce large temperature gradients, the influence of heat flow within the foil on the resultant heat transfer becomes significant. Substantial errors in the heat transfer coefficient are apparent by neglecting corrections to the measured data for the cases examined. Methods to account for these errors are presented here, and demonstrated to result in an accurate measurement of the local heat transfer map on the surface

  13. Combination of interferometry and thermography data for cultural heritage structural diagnostic research

    Science.gov (United States)

    Tornari, Vivi; Andrianakis, Michalis; Hatzigiannakis, Kostas; Kosma, Kiki; Detalle, Vincent; Giovanacci, David

    2017-07-01

    The demand for non destructive and non invasive structural diagnostic techniques able to perform on field remote structural evaluation of historical structures and works of art it faces an increased demand. The techniques must have some basic important characteristics The non destructivity, accuracy, repeatability, non physical contact, portability, resolution, broad range of applicability depending on the type of artwork and the question at hand, are all among the important requirements underlying the requirement for on-field structural diagnostics. In this respect there are two known techniques that have been developed at full to provide a suited structural diagnostic application in artwork conservation. The systems presented here but discussed in detail elsewhere are stimulated infrared thermography (SIRT) and digital holographic speckle pattern interferometry (DHSPI) the prior can be found n market at commercial devise level while the latter is at laboratory prototype level. The two systems are being exploited for their complimentary advantages and in this paper are used in combined testing on art related targets according to the above criteria to confirm the enhanced diagnostic information that their complimentary use provides. Results confirm the effectiveness of each technique alone and the combination of data of both techniques in the conservation field. Each system is first briefly described and examples are given with the aim to present the suitability and appropriateness for use in structural documentation analysis and reports. The experimental work is in laboratory work-in-progress focusing on the hybriding of data synthesis.

  14. Detecting the honeycomb sandwich composite material's moisture impregnating defects by using infrared thermography technique

    International Nuclear Information System (INIS)

    Kwon, Koo Ahn; Choi, Man Yong; Park, Jeong Hak; Choi, Won Jae; Park, Hee Sang

    2017-01-01

    Many composite materials are used in the aerospace industry because of their excellent mechanical properties. However, the nature of aviation exposes these materials to high temperature and high moisture conditions depending on climate, location, and altitude. Therefore, the molecular arrangement chemical properties, and mechanical properties of composite materials can be changed under these conditions. As a result, surface disruptions and cracks can be created. Consequently, moisture-impregnating defects can be induced due to the crack and delamination of composite materials as they are repeatedly exposed to moisture absorption moisture release, fatigue environment, temperature changes, and fluid pressure changes. This study evaluates the possibility of detecting the moisture-impregnating defects of CFRP and GFRP honeycomb structure sandwich composite materials, which are the composite materials in the aircraft structure, by using an active infrared thermography technology among non-destructive testing methods. In all experiments, it was possible to distinguish the area and a number of CFRP composite materials more clearly than those of GFRP composite material. The highest detection rate was observed in the heating duration of 50 mHz and the low detection rate was at the heating duration of over 500 mHz. The reflection method showed a higher detection rate than the transmission method

  15. Appreciation of the traffic effects on the RST by infrared thermography

    Science.gov (United States)

    Khalifa, Abderrahmen; Marchetti, Mario; Buès, Michel

    2014-09-01

    Road surface temperature forecast is a key component of winter maintenance strategy in many developed countries. Numerical tools exist to help road managers to organize services and consequently to trigger de-icing operations. Forecasting strategies have been commonplace since the 1980s, and often based on numerical models. Traffic is one of the influencing parameters, specifically in urban areas. This work was undertaken to evaluate to which extent an accurate description of traffic might improve numerical model dedicated to road surface temperature forecasting. Two sets of experiments were run to detect and to quantify traffic effects on RST. First one consisted in driving above an infrared radiometer, a pyrgeometer and other atmospheric probes to measure the radiative contribution of a passing vehicle at various speeds. In the second set, an infrared camera was installed on a vehicle in an urban traffic flow. This camera was mounted on the roof and focused the pavement right behind the vehicle ahead, both circulating at the same speed. Infrared thermography indicated a fleeting contribution of traffic to RST. The temperature increase in circulated areas, with respect to uncirculated ones, does not last according to collected measurements. Measurements with atmospheric and radiometric probes provided elements to properly take into account traffic in a numerical model and to appreciate its contribution.

  16. Crack detection in oak flooring lamellae using ultrasound-excited thermography

    Science.gov (United States)

    Pahlberg, Tobias; Thurley, Matthew; Popovic, Djordje; Hagman, Olle

    2018-01-01

    Today, a large number of people are manually grading and detecting defects in wooden lamellae in the parquet flooring industry. This paper investigates the possibility of using the ensemble methods random forests and boosting to automatically detect cracks using ultrasound-excited thermography and a variety of predictor variables. When friction occurs in thin cracks, they become warm and thus visible to a thermographic camera. Several image processing techniques have been used to suppress the noise and enhance probable cracks in the images. The most successful predictor variables captured the upper part of the heat distribution, such as the maximum temperature, kurtosis and percentile values 92-100 of the edge pixels. The texture in the images was captured by Completed Local Binary Pattern histograms and cracks were also segmented by background suppression and thresholding. The classification accuracy was significantly improved from previous research through added image processing, introduction of more predictors, and by using automated machine learning. The best ensemble methods reach an average classification accuracy of 0.8, which is very close to the authors' own manual attempt at separating the images (0.83).

  17. Investigation into rare earth n-aminobenzoates by thermography and IR spectroscopy

    International Nuclear Information System (INIS)

    Efremova, G.I.; Buchkova, R.T.; Lapitskaya, A.V.; Pirkes, S.B.

    1977-01-01

    N-aminobenzoates of r.e.e. of the composition of M(C 6 H 4 NH 2 COO) 3 x nH 2 O have been studied by thermography and infrared spectroscopy (M=La,Ce,Pr,Nd,Sm,Eu,Cd,TdHo,Er, Tm,Yb,Lu; n=1,2). It has been established that thermal decomposition of crystallohydrates of r.e.e. n-aminobenzoates is accompanied by the formation as intermediates of non-aqueous r.e.e. n-aminobenzoates stable within a rather wide temperature range (200-300 deg). The final products of thermolysis are oxides of the corresponding r.e.e. The assignment is given of the main absorption bands in infrared spectra of n-aminobenzoates of r.e.e. The assumptions have been made about their nature: crystallization water in crystallohydrates is outward of the sphere and connected with the ligand aminogroup; the metal is, evidently, not coordinated with the nitrogen of the aminogroup. n-aminobenzoate ion is a bidentate ligand

  18. Thermal analysis of fused deposition modeling process using infrared thermography imaging and finite element modeling

    Science.gov (United States)

    Zhou, Xunfei; Hsieh, Sheng-Jen

    2017-05-01

    After years of development, Fused Deposition Modeling (FDM) has become the most popular technique in commercial 3D printing due to its cost effectiveness and easy-to-operate fabrication process. Mechanical strength and dimensional accuracy are two of the most important factors for reliability of FDM products. However, the solid-liquid-solid state changes of material in the FDM process make it difficult to monitor and model. In this paper, an experimental model was developed to apply cost-effective infrared thermography imaging method to acquire temperature history of filaments at the interface and their corresponding cooling mechanism. A three-dimensional finite element model was constructed to simulate the same process using element "birth and death" feature and validated with the thermal response from the experimental model. In 6 of 9 experimental conditions, a maximum of 13% difference existed between the experimental and numerical models. This work suggests that numerical modeling of FDM process is reliable and can facilitate better understanding of bead spreading and road-to-road bonding mechanics during fabrication.

  19. Assessment of anxiety in open field and elevated plus maze using infrared thermography.

    Science.gov (United States)

    Lecorps, Benjamin; Rödel, Heiko G; Féron, Christophe

    2016-04-01

    Due to their direct inaccessibility, affective states are classically assessed by gathering concomitant physiological and behavioral measures. Although such a dual approach to assess emotional states is frequently used in different species including humans, the invasiveness of procedures for physiological recordings particularly in smaller-sized animals strongly restricts their application. We used infrared thermography, a non-invasive method, to assess physiological arousal during open field and elevated plus maze tests in mice. By measuring changes in surface temperature indicative of the animals' emotional response, we aimed to improve the inherently limited and still controversial information provided by behavioral parameters commonly used in these tests. Our results showed significant and consistent thermal responses during both tests, in accordance with classical physiological responses occurring in stressful situations. Besides, we found correlations between these thermal responses and the occurrence of anxiety-related behaviors. Furthermore, initial temperatures measured at the start of each procedure (open field, elevated plus maze), which can be interpreted as a measure of the animals' initial physiological arousal, predicted the levels of activity and of anxiety-related behaviors displayed during the tests. Our results stress the strong link between physiological correlates of emotions and behaviors expressed during unconditioned fear tests. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Upgraded acceptance criteria from transient thermography control for the W7-X divertor target elements

    Energy Technology Data Exchange (ETDEWEB)

    Missirlian, M. [CEA, IRFM, F-13108 Saint-Paul-Lez-Durance (France)], E-mail: marc.missirlian@cea.fr; Boscary, J. [Max-Planck-Institut fuer Plasmaphysik, Euratom Association, Boltzmannstr. 2, D-85748 Garching (Germany); Guigon, R.; Schlosser, J.; Durocher, A. [CEA, IRFM, F-13108 Saint-Paul-Lez-Durance (France); Greuner, H. [Max-Planck-Institut fuer Plasmaphysik, Euratom Association, Boltzmannstr. 2, D-85748 Garching (Germany)

    2009-06-15

    The commissioning of plasma-facing component fields needs advanced non-destructive methods to detect in a reliable way the defects, which can impair the component performances and/or integrity during operation. Within this framework, CEA developed a dedicated non-destructive examination method based on active infrared thermography (SATIR facility) to inspect the bonding between armour material and metallic heat sink. Used with successful in the commissioning of the toroidal pump limiter of Tore Supra, this technique was applied in the frame of the pre-series activities of the Wendelstein 7-X high heat flux divertor elements to assess the bonding quality of the delivered components. This paper presents the methodology adopted to define an acceptance criterion based on SATIR test bed possibly applied for a serial inspection of the Wendelstein 7-X elements. Using the well-tried acceptance test based on the DTref{sub m}ax parameter, the new method includes advanced data post-processing techniques from thermo-signal SATIR and a data merging method to help the decision-making and to optimise the reliability of the binary response expected for a final decision in terms of acceptance test.

  1. Upgraded acceptance criteria from transient thermography control for the W7-X divertor target elements

    International Nuclear Information System (INIS)

    Missirlian, M.; Boscary, J.; Guigon, R.; Schlosser, J.; Durocher, A.; Greuner, H.

    2009-01-01

    The commissioning of plasma-facing component fields needs advanced non-destructive methods to detect in a reliable way the defects, which can impair the component performances and/or integrity during operation. Within this framework, CEA developed a dedicated non-destructive examination method based on active infrared thermography (SATIR facility) to inspect the bonding between armour material and metallic heat sink. Used with successful in the commissioning of the toroidal pump limiter of Tore Supra, this technique was applied in the frame of the pre-series activities of the Wendelstein 7-X high heat flux divertor elements to assess the bonding quality of the delivered components. This paper presents the methodology adopted to define an acceptance criterion based on SATIR test bed possibly applied for a serial inspection of the Wendelstein 7-X elements. Using the well-tried acceptance test based on the DTref m ax parameter, the new method includes advanced data post-processing techniques from thermo-signal SATIR and a data merging method to help the decision-making and to optimise the reliability of the binary response expected for a final decision in terms of acceptance test.

  2. Mechanical design and thermo-hydraulic simulation of the infrared thermography diagnostic of the WEST tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Micolon, Frédéric, E-mail: frederic.micolon@cea.fr; Courtois, Xavier; Aumeunier, Marie-Hélène; Chenevois, Jean-Pierre; Larroque, Sébastien

    2015-10-15

    The WEST (Tungsten (W) Environment in Steady state Tokamak) project is a partial rebuild of the Tore Supra tokamak to make it an X-point metallic environment machine aimed at testing ITER technologies in relevant plasma environment. For the safe operation of the WEST tokamak, infra-red (IR) thermography is a crucial diagnostic as it is a sound and reliable way to detect hotspots or abnormal heating patterns on the plasma facing components (PFCs). Thus WEST will be fitted with middle/short-IR (1.5–2 μm or 3–5 μm) cameras in the upper port plugs to get a full view of the critical PFCs (in particular the new lower divertor) and radio-frequency (RF) heating antennas and one camera at the equatorial level to monitor the new upper divertor and the first wall. This paper describes the design of the up-to-date optical system along with the hydraulic analysis and the thermal and mechanical finite element analysis conducted to ensure adequate heat extraction capabilities. Boundary conditions and simulation results will be presented and discussed as well as technological solutions retained.

  3. Temperature mapping of laser-induced hyperthermia in an ocular phantom using magnetic resonance thermography.

    Science.gov (United States)

    Maswadi, Saher M; Dodd, Stephen J; Gao, Jia-Hong; Glickman, Randolph D

    2004-01-01

    Laser-induced heating in an ocular phantom is measured with magnetic resonance thermography (MRT) using temperature-dependent phase changes in proton resonance frequency. The ocular phantom contains a layer of melanosomes isolated from bovine retinal pigment epithelium. The phantom is heated by the 806-nm output of a continuous wave diode laser with an irradiance of 2.4 to 21.6 W/cm2 in a beam radius of 0.8 or 2.4 mm, depending on the experiment. MRT is performed with a 2 T magnet, and a two-turn, 6-cm-diam, circular radio frequency coil. Two-dimensional temperature gradients are measured within the plane of the melanin layer, as well as normal to it, with a temperature resolution of 1 degrees C or better. The temperature gradients extending within the melanin layer are broader than those orthogonal to the layer, consistent with the higher optical absorption and consequent heating in the melanin. The temperature gradients in the phantom measured by MRT closely approximate the predictions of a classical heat diffusion model. Three-dimensional temperature maps with a spatial resolution of 0.25 mm in all directions are also made. Although the temporal resolution is limited in the prototype system (22.9 s for a single image "slice"), improvements in future implementations are likely. These results indicate that MRT has sufficient spatial and temperature resolution to monitor target tissue temperature during transpupillary thermotherapy in the human eye.

  4. Determining the dimension of subsurface defects by active infrared thermography – experimental research

    Directory of Open Access Journals (Sweden)

    S. Grys

    2018-03-01

    Full Text Available This paper presents research into a method of processing thermal images aimed at detecting and characterizing material defects, or non-uniformities, of the internal structure of materials. Active thermography was chosen as the NDT method. Hidden defects were revealed by analysing the temperature field of the tested material's front surface which was externally excited with heating lamps. Background removal and image segmentation were applied to the last thermogram in the sequence recorded at the end of the heating phase. The paper focuses on the quality of determining lateral dimensions of subsurface flaws in a polymethylmethacrylate slab with bottom holes drilled to imitate flaws. The following accuracy-affecting factors were taken into account: defect depth, emissivity of the inspected surface as an input, user-set parameter for the IR camera, type of filtering used to eliminate the effect of non-uniformity when heating the object surface with an external source, and global and local thresholding as a segmentation method used for defect detection and sizing.

  5. Infrared Thermography Sensor for Temperature and Speed Measurement of Moving Material.

    Science.gov (United States)

    Usamentiaga, Rubén; García, Daniel Fernando

    2017-05-18

    Infrared thermography offers significant advantages in monitoring the temperature of objects over time, but crucial aspects need to be addressed. Movements between the infrared camera and the inspected material seriously affect the accuracy of the calculated temperature. These movements can be the consequence of solid objects that are moved, molten metal poured, material on a conveyor belt, or just vibrations. This work proposes a solution for monitoring the temperature of material in these scenarios. In this work both real movements and vibrations are treated equally, proposing a unified solution for both problems. The three key steps of the proposed procedure are image rectification, motion estimation and motion compensation. Image rectification calculates a front-parallel projection of the image that simplifies the estimation and compensation of the movement. Motion estimation describes the movement using a mathematical model, and estimates the coefficients using robust methods adapted to infrared images. Motion is finally compensated for in order to produce the correct temperature time history of the monitored material regardless of the movement. The result is a robust sensor for temperature of moving material that can also be used to measure the speed of the material. Different experiments are carried out to validate the proposed method in laboratory and real environments. Results show excellent performance.

  6. Infrared thermography: A potential noninvasive tool to monitor udder health status in dairy cows

    Directory of Open Access Journals (Sweden)

    M. Sathiyabarathi

    2016-10-01

    Full Text Available The animal husbandry and livestock sectors play a major role in the rural economy, especially for the small and marginal farmers. India has the largest livestock population in the world and ranks first in the milk production. Mastitis is the most common and expensive infectious disease in dairy cattle. The global economic losses per year due to mastitis amounts to USD 35 billion and for Indian dairy industry INR 6000 crores per year. Early detection of mastitis is very important to reduce the economic loss to the dairy farmers and dairy industry. Automated methods for early and reliable detection of mastitis are currently in focus under precision dairying. Skin surface temperature is an important indicator for the diagnosis of cow’s illnesses and for the estimation of their physiological status. Infrared thermography (IRT is a simple, effective, on-site, and noninvasive method that detects surface heat, which is emitted as infrared radiation and generates pictorial images without causing radiation exposure. In human and bovine medicine, IRT is used as a diagnostic tool for assessment of normal and physiological status.

  7. Study on the defects detection in composites by using optical position and infrared thermography

    Energy Technology Data Exchange (ETDEWEB)

    Kwn, Koo Ahn; Choi, Man Yong; Park, Jeong Hak; Choi, Won Jae [Safety Measurement Center, Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of); Park, Hee Sang [Dept. of Research and Development, Korea Research Institute of Smart Material and Structures System Association, Daejeon (Korea, Republic of)

    2016-04-15

    Non-destructive testing methods for composite materials (e.g., carbon fiber-reinforced and glass fiber-reinforced plastic) have been widely used to detect damage in the overall industry. This study detects defects using optical infrared thermography. The transient heat transport in a solid body is characterized by two dynamic quantities, namely, thermal diffusivity and thermal effusivity. The first quantity describes the speed with thermal energy diffuses through a material, whereas the second one represents a type of thermal inertia. The defect detection rate is increased by utilizing a lock-in method and performing a comparison of the defect detection rates. The comparison is conducted by dividing the irradiation method into reflection and transmission methods and the irradiation time into 50 mHz and 100 mHz. The experimental results show that detecting defects at 50 mHz is easy using the transmission method. This result implies that low-frequency thermal waves penetrate a material deeper than the high-frequency waves.

  8. Augmented reality and dynamic infrared thermography for perforator mapping in the anterolateral thigh.

    Science.gov (United States)

    Cifuentes, Ignacio Javier; Dagnino, Bruno Leonardo; Salisbury, María Carolina; Perez, María Eliana; Ortega, Claudia; Maldonado, Daniela

    2018-05-01

    Dynamic infrared thermography (DIRT) has been used for the preoperative mapping of cutaneous perforators. This technique has shown a positive correlation with intraoperative findings. Our aim was to evaluate the accuracy of perforator mapping with DIRT and augmented reality using a portable projector. For this purpose, three volunteers had both of their anterolateral thighs assessed for the presence and location of cutaneous perforators using DIRT. The obtained image of these "hotspots" was projected back onto the thigh and the presence of Doppler signals within a 10-cm diameter from the midpoint between the lateral patella and the anterior superior iliac spine was assessed using a handheld Doppler device. Hotspots were identified in all six anterolateral thighs and were successfully projected onto the skin. The median number of perforators identified within the area of interest was 5 (range, 3-8) and the median time needed to identify them was 3.5 minutes (range, 3.3-4.0 minutes). Every hotspot was correlated to a Doppler sound signal. In conclusion, augmented reality can be a reliable method for transferring the location of perforators identified by DIRT onto the thigh, facilitating its assessment and yielding a reliable map of potential perforators for flap raising.

  9. Using lock-in infrared thermography for the visualization of the hand vascular tree

    Science.gov (United States)

    Bouzida, Nabila; Bendada, Abdel Hakim; Piau, Jean-Marc; Akhloufi, Moulay; Maldague, Xavier; Raymond, Mathieu

    2008-03-01

    An imaging technique of the hand vein tree is presented in this paper. Using the natural human circulatory system and a controlled armband pressure around the arm, a lock-in thermography technique with an internal excitation is carried out. Since the stimulation frequency is inversely proportional to the inspection depth, the subcutaneous layer requires the use of a very slow frequency. Thus, a sawtooth waveform is preferred to minimize the duration of the pressure applied to the armband during the experiment. A frequency of approximately 0.03 Hz and a pressure range between 100 and 140 mmHg, according to the diastolic and systolic blood pressure, are used as stimulation. Then, dorsal hand amplitude and phase images are obtained with IR_view (Klein, 1999), a tool specifically designed to analyze infrared images. The hand vein structure is thermally mapped by an infrared camera operating in the middle wavelength infrared range (MWIR) at room temperature. Parasitic frequencies are avoided by keeping the hand fixed. The resulting images show a gradient of temperature between surrounding tissues and the back-of-hand veins. The vascular signature segmentation is extracted from the amplitude and phase images by using a Fast Fourier Transform image processing technique. This work could be used for vein localization for perfusion or for the early diagnosis of vein diseases such as primitive varicose and deep vein thrombosis (DVT). A hand vein signature database for identification purposes is also possible.

  10. On the use of infrared thermography in studies with air curtain devices

    Energy Technology Data Exchange (ETDEWEB)

    Neto, L. P. C. [Departamento de Engenharia Industrial, Escola Superior de Tecnologia, Instituto Politecnico de Castelo Branco, Castelo Branco (Portugal); Silva, M. C. G.; Costa, J. J. [Departamento de Engenharia Mecanica, Faculdade de Ciencias e Tecnologia da Universidade de Coimbra, Polo II, Coimbra (Portugal)

    2006-07-01

    Among the different existing methods to characterise the aerodynamic sealing effect provided by an air curtain device placed over the opening between two contiguous compartments, infrared thermography has revealed to be a very useful tool. Besides allowing the capture, in an expedite way, of instantaneous images of the temperature field in the neighbourhood of the door, the technique hereon described has other advantages, in terms of quick and easy setup, low intrusive character and liability of obtained results. To apply this method, a large sheet of paper was stretched in the direction perpendicular to the opening where the air curtain device has placed to allow the registration of pictures or video sequences with an infrared camera setup in its maximum sensitivity. Good concordance between the thermographs obtained with this technique and the temperature fields measured for the same plane with a rack of 16 low velocity omni-directional thermal anemometer probes allowed its validation. Various elucidative examples of the use of this technique as a complementary tool for analysis and visualization of the complex physical phenomena occurring for the studied flow are presented in this article. (author)

  11. Automatic detection of diabetic foot complications with infrared thermography by asymmetric analysis

    Science.gov (United States)

    Liu, Chanjuan; van Netten, Jaap J.; van Baal, Jeff G.; Bus, Sicco A.; van der Heijden, Ferdi

    2015-02-01

    Early identification of diabetic foot complications and their precursors is essential in preventing their devastating consequences, such as foot infection and amputation. Frequent, automatic risk assessment by an intelligent telemedicine system might be feasible and cost effective. Infrared thermography is a promising modality for such a system. The temperature differences between corresponding areas on contralateral feet are the clinically significant parameters. This asymmetric analysis is hindered by (1) foot segmentation errors, especially when the foot temperature and the ambient temperature are comparable, and by (2) different shapes and sizes between contralateral feet due to deformities or minor amputations. To circumvent the first problem, we used a color image and a thermal image acquired synchronously. Foot regions, detected in the color image, were rigidly registered to the thermal image. This resulted in 97.8%±1.1% sensitivity and 98.4%±0.5% specificity over 76 high-risk diabetic patients with manual annotation as a reference. Nonrigid landmark-based registration with B-splines solved the second problem. Corresponding points in the two feet could be found regardless of the shapes and sizes of the feet. With that, the temperature difference of the left and right feet could be obtained.

  12. Dynamic Infrared Thermography of Nanoheaters Embedded in Skin-Equivalent Phantoms

    Directory of Open Access Journals (Sweden)

    K. A. López-Varela

    2018-01-01

    Full Text Available Nanoheaters are promising tools for localized photothermal therapy (PTT of malignant cells. The anisotropic AuNPs present tunable surface plasmon resonances (SPR with ideal NIR optical response to be applied as theranostic agents. To this purpose, nanoparticles with branches are suitable because of the electromagnetic field concentrated at their vertices. We standardized a protocol to synthesize multibranched gold nanoparticles (MB-AuNPs by the seed-growth method and found a size-seed dependence tunability on the hierarchy of branching. Once the optical response is evaluated, we tested the temporal stability as nanoheaters of the MB-AuNPs immersed in skin-equivalent phantoms by dynamic infrared thermography (DIRT. The most suited sample presents a concentration of 5.2×108 MB-AuNPs/mL showing good thermal stability with ΔT = 4.5°C, during 3 cycles of 10 min at 785 nm laser irradiation with power of 0.15 W. According to these results, the MB-AuNPs are suitable nanoheaters to be tested for PTT in more complex models.

  13. Simultaneous monitoring of ice accretion and thermography of an airfoil: an IR imaging methodology

    International Nuclear Information System (INIS)

    Mohseni, M; Frioult, M; Amirfazli, A

    2012-01-01

    A novel image analysis methodology based on infrared (IR) imaging was developed for simultaneous monitoring of ice accretion and thermography of airfoils. In this study, an IR camera was calibrated and used to measure the surface temperature of the energized airfoils, and monitor the ice accretion and growth pattern on the airfoils’ surfaces. The methodology comprises the automatic processing of a series of IR video frames with the purpose of detecting ice pattern evolution during the icing test period. A specially developed MATLAB code was used to detect the iced areas in the IR images, and simultaneously monitor surface temperature evolution of the airfoil during an icing test. Knowing the correlation between the icing pattern and surface temperature changes during an icing test is essential for energy efficient design of thermal icing mitigation systems. Processed IR images were also used to determine the ice accumulation rate on the airfoil's surface in a given icing test. The proposed methodology has been demonstrated to work successfully, since the optical images taken at the end of icing tests from the airfoils’ surfaces compared well with the processed IR images detecting the ice grown outward from the airfoils’ leading edge area. (paper)

  14. Rheology, thermography, and interlayer welding in polymer extrusion 3D printing

    Science.gov (United States)

    Seppala, Jonathan; Davis, Chelsea; Migler, Kalman

    In polymer extrusion 3D printing, thermoplastic filament is extruded though a rastering nozzle onto previously deposited layers. The resulting strength of the 3D produced part is limited by the strength of the weld between each layer. During this thermal processing, the temperature of the interface between layers dictates the chain mobility, interdiffusion, entanglement, and thus weld strength. In quiescent welding experiments, it has been found that the weld strength in symmetric linear polymer systems scales with t 0.25, where t is the isothermal annealing time, before plateauing to the bulk strength. However, 3D printing is highly non isothermal and we calculated an equivalent isothermal annealing time using a combination of in situ infrared thermography and horizontal shift factors from offline rheological measurements of the neat polymer. Interlayer adhesion energy was measured directly by mode III fracture using a simplified geometry limiting the measurement to a single interlayer. Since the processing conditions are known a prioi this approach provides the data needed to estimate the final build strength at time of design. The resulting agreement between annealing time and adhesion energy for a range of printing conditions and thermoplastics are discussed.

  15. Multispectral Applications of Infrared Thermography in the Diagnosis and Protection of Built Cultural Heritage

    Directory of Open Access Journals (Sweden)

    Antonia Moropoulou

    2018-02-01

    Full Text Available Infrared thermography (IRT is a powerful non contact imaging technique, appropriate for the protection of cultural heritage. The National Technical University of Athens research team (scientist responsible: A. Moropoulou, started to use this technique in the early 1990s, in all stages of a conservation project, from decay diagnosis to assessment of conservation interventions and monitoring. The monuments investigated with the aid of this technique belonged to different historical periods, dating from antiquity to modern times. The main products of IRT, thermal maps of surfaces, were evaluated and exploited, based on the demands, special needs and requirements of each application. Additionally, in laboratory scale, many IRT measurements were performed in order to investigate the applicability and limitations of this technique for measuring a material’s thermophysical properties. All these data and accumulated knowledge and experience contributed to a set of recommendations, which enabled us to compile a protocol for the application of this technique in a more standardized way. Moreover, the added value of this practice permitted the successful application and integration of this technique in large-scale conservation projects, such as the Pythian Apollo Temple in Acropolis of Rhodes, during the diagnostic study phase, or at the Holy Aedicule, of the Holy Selphuchre in Jerusalem, during the rehabilitation works.

  16. Baby sleeping bag and conventional bedding conditions--comparative investigations by infrared thermography.

    Science.gov (United States)

    Sauseng, W; Kerbl, R; Thaller, S; Hanzer, M; Zotter, H

    2011-09-01

    Thermal stress is a risk factor for sudden infant death syndrome (SIDS). Recently, baby sleeping bags have been recommended as a preventive measure against SIDS. The aim of this study was to describe in which way the use of baby sleeping bags might influence thermoregulation of sleeping infants and maybe the incidence of SIDS. Body surface temperature was recorded by use of infrared thermography in 15 infants (median age 49 days). Recordings were done twice: after sleeping for 60 min under a blanket and after sleeping for 60 min in a baby sleeping bag. Temperature was recorded and compared for defined sites of body surface. Infants' mean body surface temperature as well as core temperature after sleeping in a baby sleeping bag did not show significant differences when compared to infants sleeping under a conventional blanket. Under controlled conditions, core temperature and mean body surface temperature are comparable, equally if using a baby sleeping bag or conventional bedding. However, under the more uncontrolled conditions of baby care at home, sleeping bags might provide a more constant temperature profile, while other bedding conditions may lead to significant variations of temperature pattern. © Georg Thieme Verlag KG Stuttgart · New York.

  17. Automating data analysis during the inspection of boiler tubes using line scanning thermography

    Science.gov (United States)

    Ley, Obdulia; Momeni, Sepand; Ostroff, Jason; Godinez, Valery

    2012-05-01

    Failures in boiler waterwalls can occur when a relatively small amount of corrosion and loss of metal have been experienced. This study presents our efforts towards the application of Line Scanning Thermography (LST) for the analysis of thinning in boiler waterwall tubing. LST utilizes a line heat source to thermally excite the surface to be inspected and an infrared detector to record the transient surface temperature increase observed due to the presence of voids, thinning or other defects. In waterwall boiler tubes the defects that can be detected using LST correspond to corrosion pitting, hydrogen damage and wall thinning produced by inadequate burner heating or problems with the water chemistry. In this paper we discuss how the LST technique is implemented to determine thickness from the surface temperature data, and we describe our efforts towards developing a semiautomatic analysis tool to speed up the time between scanning, reporting and implementing repairs. We compare the density of data produced by the common techniques used to assess wall thickness and the data produced by LST.

  18. Endoscope diagnostic for tomography, spectroscopy and thermography on Wendelstein 7-X

    Energy Technology Data Exchange (ETDEWEB)

    Denner, Peter; Neubauer, Olaf; Schweer, Bernd; Liang, Yunfeng [Forschungszentrum Juelich GmbH, Institut fuer Energie- und Klimaforschung - Plasmaphysik, 52425 Juelich (Germany)

    2016-07-01

    Plasma-surface interaction (PSI) in the divertor region of Wendelstein 7-X (W7-X) will be of great importance for operational phase OP1.2. While the erosion of the divertor will have an impact on its lifetime and is therefore a critical subject of investigation, fundamental PSI studies in the divertor region are in many ways equally significant. These plasma-wall interactions will be influenced by impurity transport, where the complex 3D magnetic geometry will play a crucial role, but this magnetic geometry could itself be influenced by plasma effects such as Pfirsch-Schlueter and bootstrap currents. Therefore, along with measurements of obvious quantities such as heat flux, PSI research in the divertor region will also require measurements of the temperature in the plasma edge and of the concentration and distribution of different impurities, in combination with modelling of impurity transport. In order to provide the measurements necessary to address these physics questions, a set of endoscopes has been designed for visible and ultraviolet spectroscopy and tomography of the plasma edge, along with infrared thermography of the divertor tiles. An overview of this endoscope diagnostic system is presented. Details of the measurements to be taken and their relationship to physics issues such as impurity transport and erosion of the divertor are discussed.

  19. Breast reconstruction - natural tissue

    Science.gov (United States)

    ... flap; TRAM; Latissimus muscle flap with a breast implant; DIEP flap; DIEAP flap; Gluteal free flap; Transverse upper gracilis flap; TUG; Mastectomy - breast reconstruction with natural tissue; Breast cancer - breast reconstruction with natural tissue

  20. Breast Cancer: Treatment Options

    Science.gov (United States)

    ... Breast Cancer > Breast Cancer: Treatment Options Request Permissions Breast Cancer: Treatment Options Approved by the Cancer.Net Editorial ... can be addressed as quickly as possible. Recurrent breast cancer If the cancer does return after treatment for ...

  1. Breast cancer

    International Nuclear Information System (INIS)

    Delgado, L.; Krygier, G.; Castillo, C.

    2009-01-01

    This article is about the diagnosis, treatment and monitoring of breast cancer. Positive diagnosis is based on clinical mammary exam, mammography, mammary ultrasonography, and histological study. Before the chemotherapy and radiotherapy treatment are evaluated the risks

  2. Breast Augmentation

    Science.gov (United States)

    ... Administration (FDA) has identified a possible association between breast implants and the development of anaplastic large cell lymphoma (ALCL), a rare cancer of the immune system. The FDA believes that ...

  3. Breast Augmentation

    African Journals Online (AJOL)

    1974-04-13

    Apr 13, 1974 ... Complications encountered after breast augmentation are dealt with in .... in Phisohex or other suitable preparation for a few days before surgery ... In all cases, the prosthesis causes a fibrous tissue capsule to form around it.

  4. Breast Cancer

    Science.gov (United States)

    ... modulators and aromatase inhibitors, reduce the risk of breast cancer in women with a high risk of the disease. These medications carry a risk of side effects, so doctors reserve these medications for women who ...

  5. Monitoring of a burning conical heap by combining topographical mapping with infrared thermography; Surveillance d'un terril conique en combustion par couplage de releves topographiques et de thermographie infrarouge

    Energy Technology Data Exchange (ETDEWEB)

    Carpentier, O.; Antczak, E.; Defer, D.; Duthoit, B. [Faculte des Sciences Appliquees, LAMH - MTI, 62 - Bethune (France)

    2003-07-01

    One of the most used method for monitoring a slag heap is the air infrared thermography. Even if it permit to survey a large area and provide a well contrasted display of dangerous areas, this method is expensive, perturbed by atmospheric conditions and cannot offer an accurate localization of defects. In order to mitigate this disadvantage, the LAMH, in association with Groupe Charbonnages de France, set up a method based on topographic and infrared thermographic cross reading which is more accurate, less expensive and, in a near future, will permit a monitoring of combustion reaction. (authors)

  6. Diagnosis of the Main Busbar II Panel Components Ageing of RSG-GAS Electrical System by Using Infrared Thermography

    International Nuclear Information System (INIS)

    Teguh Sulistyo; Kiswanto; Roziq Himawan; Ari Satmoko

    2007-01-01

    To support the operation of RSG-GAS safely, the diagnosis of the ageing of main busbar II BHD/BHE/BHF panel components of RSG-GAS electrical system have been done. By using infrared thermography type Thermo Tracer TH9100PM VI/PW VI. The results of the diagnosis showed that some of the components under degradation with various rate. It can cause the system failure. By understanding the components ageing degradation mechanism and performing the preventive and predictive maintenance and safety of RSG-GAS electrical system earlier, the possibility of accident can be avoided. (author)

  7. Who should do what in environmental management? Twelve principles for allocating responsibilities

    NARCIS (Netherlands)

    Mostert, E.

    2015-01-01

    In environmental management there is often discussion on the allocation of responsibilities. Such discussions can continue for a long time and can form an obstacle for effective action. In this article twelve normative principles for the allocation of responsibilities are identified, coming from

  8. Key lessons: Twelve factors critical to the success of WDM at the ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    English · Français ... Key lessons: Twelve factors critical to the success of WDM at the policy and at the operational levels ... from slums in central New Delhi to the city's desolate periphery face daily indignities and danger as they collect water o.

  9. Peucedanum ostruthium (L. Koch: Morphological and phytochemical variability of twelve accessions from the Swiss alpine region

    Directory of Open Access Journals (Sweden)

    McCardell, Jessica Heather

    2016-07-01

    Full Text Available Ostruthin, a natural bioactive compound mainly occurring in the roots of Peucedanum ostruthium, is the focus of this study. P. ostruthium was collected from twelve locations in the Swiss alpine region and reared in an experimental field, subdivided into twelve lots over two years. In the spring and fall, a portion of each of the twelve accessions was harvested and separated into above and below ground plant parts. The dried plants were then extracted with 60 % ethanol using accelerated solvent extraction (ASE and analyzed using high pressure liquid chromatography (HPLC.The above and below ground plant parts were then analyzed concerning their dry matter yield (DMY, their ostruthin concentration and their ostruthin yield. Focusing on ostruthin, it was found that the below ground plant parts harvested in the fall rendered the highest ostruthin yield. Furthermore, a variability concerning ostruthin among the twelve accessions was found. This variability among the accessions is of interest with regards to a breeding program used to develop a cultivar with a high ostruthin yield.

  10. Portrayal of Life Form in Selected Biographies for Children Eight to Twelve Years of Age.

    Science.gov (United States)

    Koch, Shirley Lois

    This study describes and analyzes, in a critical literary manner, selected biographies for children eight to twelve years of age. Biographies of Jane Addams, Cesar Chavez, Mohandas Gandhi, Toyohiko Kagawa, Martin Luther King, Jr., and Albert Schweitzer are viewed from the perspective of a literary criterion based on the principles of design to…

  11. Isolation and characterization of twelve microsatellite loci for the Japanese Devilray (Mobula japanica)

    NARCIS (Netherlands)

    Poortvliet, Marloes; Galvan-Magana, Felipe; Bernardi, Giacomo; Croll, Donald A.; Olsen, Jeanine L.

    2011-01-01

    Twelve polymorphic microsatellites loci were characterized for Mobula japanica (Japanese Devilray) using an enrichment protocol. All but two loci were in Hardy-Weinberg equilibrium with no evidence of linkage disequilibrium or null-alleles for a sample of 40 individuals from two populations. The

  12. Premarital sex in the last twelve months and its predictors among ...

    African Journals Online (AJOL)

    Background: Premarital sex increases the risk of unintended pregnancy and sexually transmitted infections including HIV if unprotected and contraception is not used. Thus, the objective of this study was to assess premarital sex in the last twelve months and its predictors among regular undergraduate students of Wollega ...

  13. The effects of planting density and cultural intensity on loblolly pine crown characteristics at age twelve

    Science.gov (United States)

    Madison Akers; Michael Kane; Robert Teskey; Richard Daniels; Dehai Zhao; Santosh Subedi

    2012-01-01

    Twelve-year old loblolly pine (Pinus taeda L.) stands were analyzed for the effects of planting density and cultural intensity on tree and crown attributes. Four study installations were located in the Piedmont and Upper Coastal Plain regions of the U.S. South. The treatments included six planting densities (740, 1480, 2220, 2960, 3700, 4440 trees...

  14. Magnetic resonance imaging of the human female breast. Current status and pathologic correlations

    International Nuclear Information System (INIS)

    Powell, D.E.; Stelling, C.B.

    1988-01-01

    In the field of breast cancer, attention has focused on the problem of detection and diagnosis of the tumor in its early stages as the best means of reducing mortality. Many imaging modalities have been applied to breast cancer, including mammography, ultrasonography, computerized tomography, and thermography. More recently interest has turned to NMR or magnetic resonance (MR) imaging (as it is termed in more current usage) for the detection of breast disease and particularly carcinoma of the breast. This review discusses the present role of MR imaging in the diagnosis of breast lesions based on work from several institutions. Possible areas for future development to increase the usefulness of MR as a diagnostic modality are discussed. For those not familiar with terminology used in the field of MR, a short glossary of terms is supplied at the end of the chapter. Some general references on MR imaging are give at the end of the references for those wishing to review the subject in general

  15. Supportive Noninvasive Tool for the Diagnosis of Breast Cancer Using a Thermographic Camera as Sensor

    Directory of Open Access Journals (Sweden)

    Marco Antonio Garduño-Ramón

    2017-03-01

    Full Text Available Breast cancer is the leading disease in incidence and mortality among women in developing countries. The opportune diagnosis of this disease strengthens the survival index. Mammography application is limited by age and periodicity. Temperature is a physical magnitude that can be measured by using multiple sensing techniques. IR (infrared thermography using commercial cameras is gaining relevance in industrial and medical applications because it is a non-invasive and non-intrusive technology. Asymmetrical temperature in certain human body zones is associated with cancer. In this paper, an IR thermographic sensor is applied for breast cancer detection. This work includes an automatic breast segmentation methodology, to spot the hottest regions in thermograms using the morphological watershed operator to help the experts locate the tumor. A protocol for thermogram acquisition considering the required time to achieve a thermal stabilization is also proposed. Breast thermograms are evaluated as thermal matrices, instead of gray scale or false color images, increasing the certainty of the provided diagnosis. The proposed tool was validated using the Database for Mastology Research and tested in a voluntary group of 454 women of different ages and cancer stages with good results, leading to the possibility of being used as a supportive tool to detect breast cancer and angiogenesis cases.

  16. Evaluation of digital infra-red thermal imaging as an adjunctive screening method for breast carcinoma: a pilot study.

    Science.gov (United States)

    Rassiwala, Muffazzal; Mathur, Poonam; Mathur, Rajkumar; Farid, Khan; Shukla, Sapna; Gupta, P K; Jain, Beena

    2014-12-01

    Early screening plays a pivotal role in management of breast cancer. Given the socio-economic situation in India, there is a strong felt need for a screening tool which reaches the masses rather than waiting for the masses to reach tertiary centers to be screened. Digital infra-red thermal imaging (DITI) or breast thermography as a screening test offers this possibility and needs to be carefully assessed in Indian scenario. The study involved 1008 female patients of age 20-60 years that had not been diagnosed of cancer of breast earlier. All the subjects in this population were screened for both the breasts using DITI. Based on the measured temperature gradients (ΔT) in thermograms, the subjects were classified in one of the three groups, normal (ΔT ≤ 2.5), abnormal (ΔT > 2.5, breast cancer (ΔT ≥ 3). All those having (ΔT > 2.5) underwent triple assessment that consisted of clinical examination, radiological and histopathological examination. Those with normal thermograms were subjected to only clinical examination. Forty nine female breasts had thermograms with temperature gradients exceeding 2.5 and were subjected to triple assessment. Forty one of these which had ΔT ≥ 3 were proven to be having cancer of breast and were offered suitable treatment. Eight thermograms had temperature gradients exceeding 2.5 but less than 3. Most of these were lactating mothers or had fibrocystic breast diseases. As a screening modality, DITI showed sensitivity of 97.6%, specificity of 99.17%, positive predictive value 83.67% and negative predictive value 99.89%. Based on the results of this study involving 1008 subjects for screening of breast cancer, thermography turns out to be a very useful tool for screening. Because it is non-contact, pain-free, radiation free and comparatively portable it can be used in as a proactive technique for detection of breast carcinoma. Copyright © 2014 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  17. Estimation of weld nugget temperature by thermography method in resistance projection welding process

    International Nuclear Information System (INIS)

    Setty, D.S.; Rameswara Roa, A.; Hemantha Rao, G.V.S.; Jaya Raj, R.N.

    2008-01-01

    In the Pressurized Heavy Water Reactor (PHWR) fuel manufacturing, zirconium alloy appendages like spacer and bearing pads are welded to the thin wall zirconium alloy fuel tubes by using resistance projection welding process. Out of many joining processes available, resistance-welding process is reliable, environment friendly and best suitable for mass production applications. In the fuel assembly, spacer pads are used to get the required inter-element spacing and Bearing pads are used to get the required load-bearing surface for the fuel assembly. Performance of the fuel assembly in the reactor is greatly influenced by these weld joint's quality. Phase transformation from α to β phase is not acceptable while welding these tiny appendages. At present only destructive metallography test is available for this purpose. This can also be achieved by measuring weld nugget temperature where in the phase transformation temperature for zirconium alloy material is 853 o C. The temperature distribution during resistance welding of tiny parts cannot be measured by conventional methods due to very small space and short weld times involved in the process. Shear strength, dimensional accuracy and weld microstructures are some of the key parameters used to measure the quality of appendage weld joints. Weld parameters were optimized with the help of industrial experimentation methodology. Individual projection welding by split electrode concept, and during welding on empty tube firm support is achieved on inner side of the tube by using expandable pneumatic mandrel. In the present paper, an attempt was made to measure the weld nugget temperature by thermography technique and is correlated with standard microstructures of zirconium alloy material. The temperature profiles in the welding process are presented for different welding conditions. This technique has helped in measuring the weld nugget temperature more accurately. It was observed that in the present appendage welding

  18. Thermal radiators with embedded pulsating heat pipes: Infra-red thermography and simulations

    International Nuclear Information System (INIS)

    Hemadri, Vadiraj A.; Gupta, Ashish; Khandekar, Sameer

    2011-01-01

    With the aim of exploring potential applications of Pulsating Heat Pipes (PHP), for space/terrestrial sectors, experimental study of embedded PHP thermal radiators, having two different effective Biot numbers respectively, and subjected to conjugate heat transfer conditions on their surface, i.e., natural convection and radiation, has been carried out under different thermo-mechanical boundary conditions. High resolution infrared camera is used to obtain spatial temperature profiles of the radiators. To complement the experimental study, detailed 3D computational heat transfer simulation has also been undertaken. By embedding PHP structures, it was possible to make the net thermal resistance of the mild steel radiator plate equivalent to the aluminum radiator plate, in spite of the large difference in their respective thermal conductivities (k Al ∼ 4k MS ). The study reveals that embedded PHP structures can be beneficial only under certain boundary conditions. The degree of isothermalization achieved in these structures strongly depends on its effective Biot number. The relative advantage of embedded PHP is appreciably higher if the thermal conductivity of the radiator plate material itself is low. The study indicates that the effective thermal conductivity of embedded PHP structure is of the order of 400 W/mK to 2300 W/mK, depending on the operating conditions. - Research highlights: → Study of radiator plates with embedded Pulsating Heat Pipe by infrared thermography. → Radiator is subjected to natural convection and radiation boundary conditions. → Experimental study is supported by 3D simulation. → Effective thermal conductivity of PHPs of the order of 2000 W/mK is obtained. → Efficacy of embedded PHPs depends on the effective Biot number of the system.

  19. A cadaveric study of bone tissue temperature during pin site drilling utilizing fluoroptic thermography.

    Science.gov (United States)

    Muffly, Matthew; Winegar, Corbett; Miller, Mark Carl; Altman, Gregory

    2018-05-03

    Using fluoroptic thermography, temperature was measured during pin site drilling of intact cortical human cadaver bone with a combination of one-step drilling, graduated drilling, and one-step drilling with irrigation of 5.0 mm Schanz pins. A 1440 rpm constant force drilling was used to on tibial diaphyses while a sensor probe placed 0.5 mm adjacent to the drill hole measured temperature. Four drilling techniques on each of the tibial segments were performed: 3.5mm drill bit, 5.0mm Schanz pin, 5.0 mm Schanz pin in 3.5 mm pre-drilled entry site, 5.0 mm Schanz pin utilizing irrigation. One-step drilling using a 5.0 mm Schanz pin without irrigation produced a temperature that exceeded the threshold temperature for heat-induced injury in 5 of the 8 trials. With the other three drilling techniques, only one in24 trials produced a temperature that would result in thermal injury. This difference was found to be statistically significant (p = 0.003). The use of irrigation significantly reduced the maximum bone tissue temperature in one-step drilling of a 5.0 mm Schanz pin (p = 0.02). One-step drilling with a 3.5 mm drill bit achieved maximum temperature significantly faster than graduated drilling and drilling with irrigation using a 5.0 mm Schanz pin (p drilling with a 5.0 mm Schanz pin into cortical bone can produce temperatures that can lead to heat-induced injury. Irrigation alone can reduce the temperatures sufficiently to avoid damage. Pre-drilling can increase temperatures significantly but the extent of any injury should be small.

  20. Diverging Drought Resistance of Scots Pine Provenances Revealed by Infrared Thermography

    Directory of Open Access Journals (Sweden)

    Hannes Seidel

    2016-08-01

    Full Text Available With recent climate changes, Scots pine (Pinus sylvestris L. forests have been affected by die-off events. Assisted migration of adapted provenances mitigates drought impacts and promotes forest regeneration. Although suitable provenances are difficult to identify by traditional ecophysiological techniques, which are time consuming and invasive, plant water status can be easily assessed by infrared thermography. Thus, we examined the stress responses of 2-year-old potted Scots pine seedlings from six provenances (Bulgaria, France, Germany, Italy, Poland, and Spain based on two thermal indices (crop water stress index and stomatal conductance index. Both indices were derived from infrared images during a six-week drought/control treatment in a greenhouse in the summer of 2013. The pines were monitored during the stress and subsequent recovery period. After controlling for fluctuating environmental conditions, soil moisture or treatment-specific water supply was the most important driver of drought stress. The stress magnitude and response to soil water deficit depended on provenance. Under moderate drought conditions, pines from western and eastern Mediterranean provenances (Bulgaria, France, and Spain expressed lower stress levels than those from both continental provenances (Germany and Poland. In pines from the Spanish and Bulgarian provenances, the stress level differences were significantly lower than in continental pines. Moreover, pines from continental provenances were less resilient (showed less recovery after the stress period than Mediterranean pines. Under extreme drought, all provenances were equally stressed with almost no significant differences in their thermal indices. Provenance-specific differences in drought resistance, which are associated with factors such as summer precipitation at the origin of Scots pine seedlings, may offer promising tracks of adaptation to future drought risks.

  1. Infrared thermography non-destructive evaluation of lithium-ion battery

    Science.gov (United States)

    Wang, Zi-jun; Li, Zhi-qiang; Liu, Qiang

    2011-08-01

    The power lithium-ion battery with its high specific energy, high theoretical capacity and good cycle-life is a prime candidate as a power source for electric vehicles (EVs) and hybrid electric vehicles (HEVs). Safety is especially important for large-scale lithium-ion batteries, especially the thermal analysis is essential for their development and design. Thermal modeling is an effective way to understand the thermal behavior of the lithium-ion battery during charging and discharging. With the charging and discharging, the internal heat generation of the lithium-ion battery becomes large, and the temperature rises leading to an uneven temperature distribution induces partial degradation. Infrared (IR) Non-destructive Evaluation (NDE) has been well developed for decades years in materials, structures, and aircraft. Most thermographic methods need thermal excitation to the measurement structures. In NDE of battery, the thermal excitation is the heat generated from carbon and cobalt electrodes in electrolyte. A technique named "power function" has been developed to determine the heat by chemical reactions. In this paper, the simulations of the transient response of the temperature distribution in the lithium-ion battery are developed. The key to resolving the security problem lies in the thermal controlling, including the heat generation and the internal and external heat transfer. Therefore, three-dimensional modelling for capturing geometrical thermal effects on battery thermal abuse behaviour is required. The simulation model contains the heat generation during electrolyte decomposition and electrical resistance component. Oven tests are simulated by three-dimensional model and the discharge test preformed by test system. Infrared thermography of discharge is recorded in order to analyze the security of the lithium-ion power battery. Nondestructive detection is performed for thermal abuse analysis and discharge analysis.

  2. Long Hole Film Cooling Dataset for CFD Development . Part 1; Infrared Thermography and Thermocouple Surveys

    Science.gov (United States)

    Shyam, Vikram; Thurman, Douglas; Poinsatte, Phillip; Ameri, Ali; Eichele, Peter; Knight, James

    2013-01-01

    An experiment investigating flow and heat transfer of long (length to diameter ratio of 18) cylindrical film cooling holes has been completed. In this paper, the thermal field in the flow and on the surface of the film cooled flat plate is presented for nominal freestream turbulence intensities of 1.5 and 8 percent. The holes are inclined at 30deg above the downstream direction, injecting chilled air of density ratio 1.0 onto the surface of a flat plate. The diameter of the hole is 0.75 in. (0.01905 m) with center to center spacing (pitch) of 3 hole diameters. Coolant was injected into the mainstream flow at nominal blowing ratios of 0.5, 1.0, 1.5, and 2.0. The Reynolds number of the freestream was approximately 11,000 based on hole diameter. Thermocouple surveys were used to characterize the thermal field. Infrared thermography was used to determine the adiabatic film effectiveness on the plate. Hotwire anemometry was used to provide flowfield physics and turbulence measurements. The results are compared to existing data in the literature. The aim of this work is to produce a benchmark dataset for Computational Fluid Dynamics (CFD) development to eliminate the effects of hole length to diameter ratio and to improve resolution in the near-hole region. In this report, a Time-Filtered Navier Stokes (TFNS), also known as Partially Resolved Navier Stokes (PRNS), method that was implemented in the Glenn-HT code is used to model coolant-mainstream interaction. This method is a high fidelity unsteady method that aims to represent large scale flow features and mixing more accurately.

  3. Use of infrared thermography to assess the influence of high environmental temperature on rabbits.

    Science.gov (United States)

    de Lima, V; Piles, M; Rafel, O; López-Béjar, M; Ramón, J; Velarde, A; Dalmau, A

    2013-10-01

    The aim of this work was to ascertain if infrared thermography (IRT) can be used on rabbits to assess differences in surface body temperature when they are subjected to two different environmental temperatures outside the comfort zone. Rabbits housed in room A were maintained at a temperature of below 30°C and rabbits in room B at a temperature of above 32°C for a year. Faeces were collected six times during the year to assess stress by means of faecal cortisol metabolites (FCM). The assessment of IRT was carried out to assess maximum and minimum temperatures on the eyes, nose and ears. FCM concentration was higher in room B than A, to confirm that stress conditions were higher in room B. Significant differences in IRT were found between the animals housed in both rooms. It was observed that it was more difficult for animals from room B to maintain a regular heat loss. Although all the body zones used to assess temperature with IRT gave statistical differences, the correlations found between the eyes, nose and ears were moderate, suggesting that they were giving different information. In addition, differences up to 3.36°C were found in the eye temperature of rabbits housed in the same room, with a clear effect of their position in relation to extractors and heating equipments. Therefore, IRT could be a good tool to assess heat stress in animals housed on typical rabbit farm buildings, giving a measure of how the animal is perceiving a combination of humidity, temperature and ventilation. Some face areas were better for analysing images. Minimum temperature on eyes and temperatures on nose are suggested to assess heat losses and critical areas of the farm for heat stress in rabbits. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. A methodology to determine boundary conditions from forced convection experiments using liquid crystal thermography

    Science.gov (United States)

    Jakkareddy, Pradeep S.; Balaji, C.

    2017-02-01

    This paper reports the results of an experimental study to estimate the heat flux and convective heat transfer coefficient using liquid crystal thermography and Bayesian inference in a heat generating sphere, enclosed in a cubical Teflon block. The geometry considered for the experiments comprises a heater inserted in a hollow hemispherical aluminium ball, resulting in a volumetric heat generation source that is placed at the center of the Teflon block. Calibrated thermochromic liquid crystal sheets are used to capture the temperature distribution at the front face of the Teflon block. The forward model is the three dimensional conduction equation which is solved within the Teflon block to obtain steady state temperatures, using COMSOL. Match up experiments are carried out for various velocities by minimizing the residual between TLC and simulated temperatures for every assumed loss coefficient, to obtain a correlation of average Nusselt number against Reynolds number. This is used for prescribing the boundary condition for the solution to the forward model. A surrogate model obtained by artificial neural network built upon the data from COMSOL simulations is used to drive a Markov Chain Monte Carlo based Metropolis Hastings algorithm to generate the samples. Bayesian inference is adopted to solve the inverse problem for determination of heat flux and heat transfer coefficient from the measured temperature field. Point estimates of the posterior like the mean, maximum a posteriori and standard deviation of the retrieved heat flux and convective heat transfer coefficient are reported. Additionally the effect of number of samples on the performance of the estimation process has been investigated.

  5. Application of thermography for monitoring stomatal conductance of Coffea arabica under different shading systems.

    Science.gov (United States)

    Craparo, A C W; Steppe, K; Van Asten, P J A; Läderach, P; Jassogne, L T P; Grab, S W

    2017-12-31

    Stomatal regulation is a key process in the physiology of Coffea arabica (C. arabica). Intrinsically linked to photosynthesis and water relations, it provides insights into the plant's adaptive capacity, survival and growth. The ability to rapidly quantify this parameter for C. arabica under different agroecological systems would be an indispensable tool. Using a Flir E6 MIR Camera, an index that is equivalent to stomatal conductance (I g ) was compared with stomatal conductance measurements (g s ) in a mature coffee plantation. In order to account for varying meteorological conditions between days, the methods were also compared under stable meteorological conditions in a laboratory and I g was also converted to absolute stomatal conductance values (g 1 ). In contrast to typical plant-thermography methods which measure indices once per day over an extended time period, we used high resolution hourly measurements over daily time series with 9 sun and 9 shade replicates. Eight daily time series showed a strong correlation between methods, while the remaining 10 were not significant. Including several other meteorological parameters in the calculation of g 1 did not contribute to any stronger correlation between methods. Total pooled data (combined daily series) resulted in a correlation of ρ=0.66 (P≤2.2e-16), indicating that our approach is particularly useful for situations where absolute values of stomatal conductance are not required, such as for comparative purposes, screening or trend analysis. We use the findings to advance the protocol for a more accurate methodology which may assist in quantifying advantageous microenvironment designs for coffee, considering the current and future climates of coffee growing regions. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  6. IR thermography methods for evaluation of internal defects in light composite armours

    International Nuclear Information System (INIS)

    Swiderski, W.; Szabra, D.; Szudrowicz, M.

    2009-01-01

    Complete text of publication follows. Light composite armour is a preferred solution against military and paramilitary sources of present threats as the reducing mass of battle vehicles provides a possibility of their quick air-transport. The light armours of these vehicles should be resistant against: common and rifle bullets, grenades, anti-personal mines, IED - improvised explosive devices. The range of military applications anticipated for composite armours covers a broad spectrum of materials and designs. Materials of composite armours include graphite epoxy, glass epoxy and aramid fiber composites. The composites that have been examined can include a variety of defects, such as ballistic impacts, embedded defects, manufacturing defects, thermal damage, moisture ingress and other induced defects. Methods for testing ballistic protection of light armours are known and used. First of all they consist of checking armours resistance against the bullets where the bullet velocity is known. Moreover the V50 velocity is defined during the test. In this method the V 50 velocity of a round or standard fragment is defined (according to STANAG 2920) as the velocity at which armour is penetrated at the probability 50%. The distribution of points hit by bullets or fragments on the surface of an armour is also important. In fact, only correct distribution of these points provides a guaranty for an impartial assessment of tested designs. After hitting by a bullet, shape and size of an area of damage in composite armours depends on the type and design of armour, and type of reinforcing material is particularly important. Knowledge of damage characteristics allows to arrange hitting points to avoid overlapping of damaged areas. Nondestructive testing by using IR thermography methods is very useful in evaluation of internal defects. In the paper we present the dependence between the energy of fragments/or bullets and the dimension of internal defects. (author)

  7. Influence of the ventilatory mode on acute adverse effects and facial thermography after noninvasive ventilation.

    Science.gov (United States)

    Pontes, Suzy Maria Montenegro; Melo, Luiz Henrique de Paula; Maia, Nathalia Parente de Sousa; Nogueira, Andrea da Nóbrega Cirino; Vasconcelos, Thiago Brasileiro; Pereira, Eanes Delgado Barros; Bastos, Vasco Pinheiro Diógenes; Holanda, Marcelo Alcantara

    2017-01-01

    To compare the incidence and intensity of acute adverse effects and the variation in the temperature of facial skin by thermography after the use of noninvasive ventilation (NIV). We included 20 healthy volunteers receiving NIV via oronasal mask for 1 h. The volunteers were randomly divided into two groups according to the ventilatory mode: bilevel positive airway pressure (BiPAP) or continuous positive airway pressure (CPAP). Facial thermography was performed in order to determine the temperature of the face where it was in contact with the mask and of the nasal dorsum at various time points. After removal of the mask, the volunteers completed a questionnaire about adverse effects of NIV. The incidence and intensity of acute adverse effects were higher in the individuals receiving BiPAP than in those receiving CPAP (16.1% vs. 5.6%). Thermographic analysis showed a significant cooling of the facial skin in the two regions of interest immediately after removal of the mask. The more intense acute adverse effects occurred predominantly among the participants in whom the decrease in the mean temperature of the nasal dorsum was lower (14.4% vs. 7.2%). The thermographic visual analysis of the zones of cooling and heating on the face identified areas of hypoperfusion or reactive hyperemia. The use of BiPAP mode was associated with a higher incidence and intensity of NIV-related acute adverse effects. There was an association between acute adverse effects and less cooling of the nasal dorsum immediately after removal of the mask. Cutaneous thermography can be an additional tool to detect adverse effects that the use of NIV has on facial skin. Comparar a incidência e a intensidade de efeitos adversos agudos e a variação da temperatura da pele da face através da termografia após a aplicação de ventilação não invasiva (VNI). Foram incluídos 20 voluntários sadios, de ambos os gêneros, submetidos à VNI com máscara oronasal por 1 h e divididos aleatoriamente em

  8. [Breast abscess with Salmonella typhi and review of the literature].

    Science.gov (United States)

    Delori, M; Abgueguen, P; Chennebault, J-M; Pichard, E; Fanello, S

    2007-11-01

    We report the case of a 54-year-old woman who presented with breast abscess, which appeared through a common alimentary toxi-infection with Salmonella Typhi, infection, which implied twelve patients having attended the same restaurant. With around hundred native cases a year in France, typhoid fever is not a very frequent toxi-infection. Among the known extra-intestinal manifestations of Salmonella infections, the breast abscess remains rare and the literature revealed less than ten published cases, including some revealed the disease. In our observation, the imputability of S. Typhi was retained based on the chronology of the clinical signs, specific treatments, and the successful outcome under antibiotherapy, in spite of the negativity of the breast abscess bacteriological samples. We also analyze rare cases of breast abscess due to S. Typhi found in the literature.

  9. Integration of ground-penetrating radar, ultrasonic tests and infrared thermography for the analysis of a precious medieval rose window

    Science.gov (United States)

    Nuzzo, L.; Calia, A.; Liberatore, D.; Masini, N.; Rizzo, E.

    2010-04-01

    The integration of high-resolution, non-invasive geophysical techniques (such as ground-penetrating radar or GPR) with emerging sensing techniques (acoustics, thermography) can complement limited destructive tests to provide a suitable methodology for a multi-scale assessment of the state of preservation, material and construction components of monuments. This paper presents the results of the application of GPR, infrared thermography (IRT) and ultrasonic tests to the 13th century rose window of Troia Cathedral (Apulia, Italy), affected by widespread decay and instability problems caused by the 1731 earthquake and reactivated by recent seismic activity. This integrated approach provided a wide amount of complementary information at different scales, ranging from the sub-centimetre size of the metallic joints between the various architectural elements, narrow fractures and thin mortar fillings, up to the sub-metre scale of the internal masonry structure of the circular ashlar curb linking the rose window to the façade, which was essential to understand the original building technique and to design an effective restoration strategy.

  10. Infrared thermography based studies on the effect of age on localized cold stress induced thermoregulation in human

    Science.gov (United States)

    Lahiri, B. B.; Bagavathiappan, S.; Nishanthi, K.; Mohanalakshmi, K.; Veni, L.; Saumya; Yacin, S. M.; Philip, John

    2016-05-01

    Thermoregulatory control of blood flow plays an important role in maintaining the human body temperature and it provides physiological resistance against extreme environmental thermal stresses. To understand the role of age on thermal signals from veins and the thermoregulatory mechanism, the dynamic variation of the vein temperature on the hands of 17 human subjects, under a localized cold stress, was studied using infrared thermography. It was observed that the vein temperature of the stimulated hand initially decreased with time up to a time interval (called 'inversion time'), which was attributed to the localized cutaneous vasoconstriction. Beyond inversion time, a rise in the vein temperature of the stimulated hand was observed. A shift in the inversion time to higher values was observed for the older subjects, which was attributed to the reduced efficiency and responsiveness of the cutaneous vasoconstriction mechanism in these subjects. Our studies indicated that the inversion time increased linearly with subject age with strong positive Pearson's correlation coefficient of 0.94. It was also observed that the contralateral symmetry in vasoconstriction was much lower in older subjects than the younger subjects. The absolute difference between the left and right inversion time varied between 11-118 s and 5-28 s for the older and younger subjects, respectively. Our study clearly demonstrated that infrared thermography is one of the most effective experimental tool for studying dynamic variation in vein pixel temperature under localized thermal stresses.

  11. Influence of season, age and management on scrotal thermal profile in Murrah bulls using scrotal infrared digital thermography

    Science.gov (United States)

    Ahirwar, Maneesh Kumar; Kataktalware, Mukund Amritrao; Ramesha, Kerekoppa Puttaiah; Pushpadass, Heartwin Amaladhas; Jeyakumar, Sakthivel; Revanasiddu, Deginal; Kour, Reen Jagish; Nath, Sapna; Nagaleekar, Anand Kumar; Nazar, Sayyad

    2017-12-01

    The aim of the present study was to examine the effects of non-genetic factors on scrotal thermographic profile viz., proximal pole temperature (PPT °C), mid pole temperature (MPT °C), distal pole temperature (DPT °C) and ocular temperature (OcT) of Murrah ( Bubalus bubalis) breeding bulls. A total of 109 buffalo bulls, maintained at three semen stations (SS), were monitored for scrotal surface and ocular temperatures using infrared thermography twice daily during rainy, winter and summer seasons using an FLIR i5 infrared camera and temperatures were measured. Thermograms were analysed by FLIR QuickReport v.1.2 SP2 software. Statistical analysis revealed that semen station, season, temperature humidity index (THI), housing system and timing of observations had significant ( P 80.88; system and timing of observations had a significant influence on scrotal surface temperature. The monitoring of scrotal surface temperature by infrared thermography was found to be useful in evaluating the effects of thermal stress on physiology and health of buffalo bulls.

  12. Assessing honeybee and wasp thermoregulation and energetics-New insights by combination of flow-through respirometry with infrared thermography.

    Science.gov (United States)

    Stabentheiner, Anton; Kovac, Helmut; Hetz, Stefan K; Käfer, Helmut; Stabentheiner, Gabriel

    2012-04-20

    Endothermic insects like honeybees and some wasps have to cope with an enormous heat loss during foraging because of their small body size in comparison to endotherms like mammals and birds. The enormous costs of thermoregulation call for optimisation. Honeybees and wasps differ in their critical thermal maximum, which enables the bees to kill the wasps by heat. We here demonstrate the benefits of a combined use of body temperature measurement with infrared thermography, and respiratory measurements of energy turnover (O(2) consumption or CO(2) production via flow-through respirometry) to answer questions of insect ecophysiological research, and we describe calibrations to receive accurate results.To assess the question of what foraging honeybees optimise, their body temperature was compared with their energy turnover. Honeybees foraging from an artificial flower with unlimited sucrose flow increased body surface temperature and energy turnover with profitability of foraging (sucrose content of the food; 0.5 or 1.5 mol/L). Costs of thermoregulation, however, were rather independent of ambient temperature (13-30 °C). External heat gain by solar radiation was used to increase body temperature. This optimised foraging energetics by increasing suction speed.In determinations of insect respiratory critical thermal limits, the combined use of respiratory measurements and thermography made possible a more conclusive interpretation of respiratory traces.

  13. Detection of Degradation Effects in Field-Aged c-Si Solar Cells through IR Thermography and Digital Image Processing

    Directory of Open Access Journals (Sweden)

    E. Kaplani

    2012-01-01

    Full Text Available Due to the vast expansion of photovoltaic (PV module production nowadays, a great interest is shown in factors affecting PV performance and efficiency under real conditions. Particular attention is being given to degradation effects of PV cells and modules, which during the last decade are seen to be responsible for significant power losses observed in PV systems. This paper presents and analyses degradation effects observed in severely EVA discoloured PV cells from field-aged modules operating already for 18–22 years. Temperature degradation effects are identified through IR thermography in bus bars, contact solder bonds, blisters, hot spots, and hot areas. I-V curve analysis results showed an agreement between the source of electrical performance degradation and the degradation effects in the defected cell identified by the IR thermography. Finally, an algorithm was developed to automatically detect EVA discoloration in PV cells through processing of the digital image alone in a way closely imitating human perception of color. This nondestructive and noncostly solution could be applied in the detection of EVA discoloration in existing PV installations and the automatic monitoring and remote inspection of PV systems.

  14. Contact thermography, 99mTc-plasmin scintimetry and 99mTc-plasmin scintigraphy as screening methods for deep venous thrombosis following major hip surgery

    DEFF Research Database (Denmark)

    Christensen, S W; Wille-Jørgensen, P; Kjaer, L

    1987-01-01

    Fifty-six patients scheduled for total hip alloplasty were screened for deep venous thrombosis by means of 99mTc-plasmin scintimetry, 99mTc-plasmin scintigraphy and contact thermography. Investigations were performed on the seventh postoperative day, and a total of 112 legs were examined. Bilateral...

  15. Thermography. Sae application in the energy consultancy, supervision of construction and failure analysis; Thermografie. Sicher einsetzen bei der Energieberatung, Bauueberwachung und Schadensanalyse

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, Herbert

    2011-07-01

    This guide provides all the information on the subject of thermography and provides compressed, practical and comprehensible the necessary skills for safe use in the building industry. Visualized examples and practical interpretation guides explain typical mistakes and support the proper analysis of thermal images and the selection of the correct retrofitting solutions.

  16. Breast MRI scan

    Science.gov (United States)

    ... or breast ultrasound Evaluate for possible rupture of breast implants Find any cancer that remains after surgery or chemotherapy Show blood ... Mean Abnormal results may be due to: Breast cancer Cysts Leaking or ruptured breast implants Abnormal breast tissue that is not cancer Scar ...

  17. Breast Cancer Surgery

    Science.gov (United States)

    FACTS FOR LIFE Breast Cancer Surgery The goal of breast cancer surgery is to remove the whole tumor from the breast. Some lymph nodes ... might still be in the body. Types of breast cancer surgery There are two types of breast cancer ...

  18. Vitamin and mineral intake of twelve adolescent male Kalenjin runners in western Kenya

    DEFF Research Database (Denmark)

    Christensen, Dirk Lund; Jakobsen, Jette; Friis, H

    2005-01-01

    runners was carried out to determine their micronutrient intake. MAIN OUTCOME MEASURES: Over a two-week period, samples of the main eaten food were collected for analysis of micronutrient distribution and a daily 24 recall interview performed to determine additional food intake. RESULTS: The estimated...... mg, 1309 microg, and 79 microg, respectively. CONCLUSION: Total daily micronutrient intake of the twelve Kalenjin runners was far from adequate compared to FAO/WHO daily recommended and suggested adequate intake....

  19. A Hidden Twelve-Dimensional SuperPoincare Symmetry In Eleven Dimensions

    Energy Technology Data Exchange (ETDEWEB)

    Bars, Itzhak; Deliduman, Cemsinan; Pasqua, Andrea; Zumino, Bruno

    2003-12-13

    First, we review a result in our previous paper, of how a ten-dimensional superparticle, taken off-shell, has a hidden eleven-dimensional superPoincare symmetry. Then, we show that the physical sector is defined by three first-class constraints which preserve the full eleven-dimensional symmetry. Applying the same concepts to the eleven dimensional superparticle, taken off-shell, we discover a hidden twelve dimensional superPoincare symmetry that governs the theory.

  20. Morphology of the spermathecae of twelve species of Triatominae (Hemiptera, Reduviidae) vectors of Chagas disease.

    Science.gov (United States)

    Nascimento, Juliana Damieli; Ribeiro, Aline Rimoldi; Almeida, Larissa Aguiar; de Oliveira, Jader; Mendonça, Vagner José; Cilense, Mário; da Rosa, João Aristeu

    2017-12-01

    Trypanosoma cruzi, the etiological agent of Chagas disease, is transmitted by triatomines that have been described in a large number of studies. Most of those studies are related to external morphology and taxonomy, but some biochemical, genetic and physiological studies have also been published. There are a few publications in the literature about the internal organs of Triatominae, for instance the spermathecae, which are responsible for storing and maintaining the viability of the spermatozoids until the fertilization of the oocytes. This work aims to study the spermathecae of twelve species of triatomines obtained from the Triatominae Insectarium of the Faculty of Pharmaceutical Sciences, UNESP, Araraquara, using optical microscopy and scanning electron microscopy. The spermathecae of the twelve species studied showed three morphological patterns: a) P. herreri sn, P. lignarius, P. megistus, Triatoma brasiliensis, T. juazeirensis, T. sherlocki and T. tibiamaculata have spermathecae with a thin initial portion and an oval-shaped final portion; b) R. montenegrensis, R. nasutus, R. neglectus, R. pictipes and R. prolixus have tubular and winding spermathecae; c) T. infestans has oval spermathecae. In addition to the three morphological patterns, it was noted that each of the twelve species has particular features that differentiate them. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. An investigation of pulsed phase thermography for detection of disbonds in HIP-bonded beryllium tiles in ITER normal heat flux first wall (NHF FW) components

    Energy Technology Data Exchange (ETDEWEB)

    Bushell, J., E-mail: joe.bushell@amec.com [AMEC Foster Wheeler, Booths Hall, Chelford Road, Knutsford, Cheshire WA16 8QZ, England (United Kingdom); Sherlock, P. [AMEC Foster Wheeler, Booths Hall, Chelford Road, Knutsford, Cheshire WA16 8QZ, England (United Kingdom); Mummery, P. [School of Mechanical, Aerospace and Civil Engineering, University of Manchester, England (United Kingdom); Bellin, B.; Zacchia, F. [Fusion for Energy, Josep Pla 2, Torres Diagonal Litoral B3, Barcelona (Spain)

    2015-10-15

    Highlights: • Pulsed phase thermography was trialled on Be-tiled plasma facing components. • Two components, one with known disbonds, one intact, were inspected and compared. • Finite element analysis was used to verify experimental observations. • PPT successfully detected disbonds in the failed component. • Good agreement found with ultrasonic test, though defect geometry was uncertain. - Abstract: Pulsed phase thermography (PPT) is a non destructive examination (NDE) technique, traditionally used in the Aerospace Industry for inspection of composite structures, which combines characteristics and benefits of flash thermography and lock-in thermography into a single, rapid inspection technique. The aim of this work was to evaluate the effectiveness of PPT as a means of inspection for the bond between the beryllium (Be) tiles and the copper alloy (CuCrZr) heatsink of the ITER NHF FW components. This is a critical area dictating the functional integrity of these components, as single tile detachment in service could result in cascade failure. PPT has advantages over existing thermography techniques using heated water which stress the component, and the non-invasive, non-contact nature presents advantages over existing ultrasonic methods. The rapid and non-contact nature of PPT also gives potential for in-service inspections as well as a quality measure for as-manufactured components. The technique has been appraised via experimental trials using ITER first wall mockups with pre-existing disbonds confirmed via ultrasonic tests, partnered with finite element simulations to verify experimental observations. This paper will present the results of the investigation.

  2. An investigation of pulsed phase thermography for detection of disbonds in HIP-bonded beryllium tiles in ITER normal heat flux first wall (NHF FW) components

    International Nuclear Information System (INIS)

    Bushell, J.; Sherlock, P.; Mummery, P.; Bellin, B.; Zacchia, F.

    2015-01-01

    Highlights: • Pulsed phase thermography was trialled on Be-tiled plasma facing components. • Two components, one with known disbonds, one intact, were inspected and compared. • Finite element analysis was used to verify experimental observations. • PPT successfully detected disbonds in the failed component. • Good agreement found with ultrasonic test, though defect geometry was uncertain. - Abstract: Pulsed phase thermography (PPT) is a non destructive examination (NDE) technique, traditionally used in the Aerospace Industry for inspection of composite structures, which combines characteristics and benefits of flash thermography and lock-in thermography into a single, rapid inspection technique. The aim of this work was to evaluate the effectiveness of PPT as a means of inspection for the bond between the beryllium (Be) tiles and the copper alloy (CuCrZr) heatsink of the ITER NHF FW components. This is a critical area dictating the functional integrity of these components, as single tile detachment in service could result in cascade failure. PPT has advantages over existing thermography techniques using heated water which stress the component, and the non-invasive, non-contact nature presents advantages over existing ultrasonic methods. The rapid and non-contact nature of PPT also gives potential for in-service inspections as well as a quality measure for as-manufactured components. The technique has been appraised via experimental trials using ITER first wall mockups with pre-existing disbonds confirmed via ultrasonic tests, partnered with finite element simulations to verify experimental observations. This paper will present the results of the investigation.

  3. BREAST RECONSTRUCTIONS AFTER BREAST CANCER TREATING

    Directory of Open Access Journals (Sweden)

    Erik Vrabič

    2018-02-01

    Full Text Available Background. Breasts are an important symbol of physical beauty, feminity, mothering and sexual desire through the entire history of mankind. Lost of the whole or part of the breast is functional and aesthetic disturbance for woman. It is understandable, that the woman, who is concerned over breast loss, is as appropriate as another person´s concern over the loss of a limb or other body part. Before the 1960, breast reconstruction was considered as a dangerous procedure and it was almost prohibited. Considering the psychological importance of the breast in modern society, the possibility of breast reconstruction for the woman about to undergo a mastectomy is a comforting alternative. We can perform breast reconstruction with autologous tissue (autologous reconstruction, with breast implants and combination of both methods. For autologous reconstruction we can use local tissue (local flaps, or tissue from distant parts of the body (free vascular tissue transfer. Tissue expansion must be performed first, in many cases of breast reconstructions with breast implants. Conclusions. Possibility of breast reconstruction made a big progress last 3 decades. Today we are able to reconstruct almost every defect of the breast and the entire breast. Breast reconstruction rise the quality of life for breast cancer patients. Breast reconstruction is a team work of experts from many medicine specialites. In Slovenia we can offer breast reconstruction for breast cancer patients in Ljubljana, where plastic surgeons from Clinical Department for Plastic Surgery and Burns cooperate with oncologic surgeons. Ten years ago a similar cooperation between plastic surgeons and surgeons of the Centre for Breast Diseases was established in Maribor.

  4. Breast pain

    Science.gov (United States)

    ... that reducing the amount of fat, caffeine, or chocolate in your diet helps reduce breast pain. Vitamin ... harmful, but most studies have not shown any benefit. Talk to your provider before starting any medicine or ... Louisiana State University Health Sciences Center-Shreveport, Shreveport, LA. Review provided by ...

  5. Breast Cancer

    Science.gov (United States)

    ... right away. He or she will do a physical exam. They will ask you about your health history and your family’s history of breast cancer. ... and Wellness Staying Healthy Healthy Living Travel Occupational Health First Aid and ... Pets and Animals myhealthfinder Food and Nutrition Healthy Food ...

  6. Breast lymphoma

    African Journals Online (AJOL)

    To fulfil the criteria for primary breast lymphoma, the following characteristics were reqUired: (I) technically adequate specimens; (iI) mammary tissue and lymphomatous infiltrate in close association; (iil) no evidence of concurrent widespread disease; and (iv) no previous. Haematology/Oncology Division, Department of ...

  7. Breast cancer

    CERN Multimedia

    2002-01-01

    "Cancer specialists will soon be able to compare mammograms with computerized images of breast cancer from across Europe, in a bid to improve diagnosis and treatment....The new project, known as MammoGrid, brings together computer and medical imaging experts, cancer specialists, radiologists and epidemiologists from Bristol, Oxford, Cambridge, France and Italy" (1 page).

  8. Male Breast Cancer

    Science.gov (United States)

    Although breast cancer is much more common in women, men can get it too. It happens most often to men between ... 60 and 70. Breast lumps usually aren't cancer. However, most men with breast cancer have lumps. ...

  9. Breast biopsy -- stereotactic

    Science.gov (United States)

    ... org/-/media/ACR/Files/Practice-Parameters/stereo-breast.pdf . Updated 2016. Accessed March 14, 2017. Parker C, Umphrey H, Bland K. The role of stereotactic breast biopsy in the management of breast disease. In: Cameron ...

  10. Breast Cancer in Men

    Science.gov (United States)

    ... ultrasound or a breast MRI cannot rule out breast cancer then you will need a biopsy to confirm diagnosis. If diagnosed When first diagnosed with breast cancer, many men are in shock. After all, ...

  11. MRI of the Breast

    Science.gov (United States)

    ... in evaluating women at high risk for breast cancer. MRI can successfully image the dense breast tissue common in younger women, and it can successfully image breast implants. Both of these are difficult to image using ...

  12. Male Breast Cancer

    Science.gov (United States)

    ... types of breast cancer that can occur in men include Paget's disease of the nipple and inflammatory breast cancer. Inherited genes that increase breast cancer risk Some men inherit abnormal (mutated) genes from their parents that ...

  13. Plasmacytoma of the Breast

    African Journals Online (AJOL)

    GB

    2015-10-04

    Oct 4, 2015 ... The clinical diagnosis of a breast plasmacytoma is ... lead to a diagnosis of breast plasmacytoma (1-3). Bone marrow ... breast cancer cases present at an advanced stage, ... pelvic ultrasonography, were normal, Bence Jones.

  14. Breast Cancer Disparities

    Science.gov (United States)

    ... 2.65 MB] Read the MMWR Science Clips Breast Cancer Black Women Have Higher Death Rates from Breast ... of Page U.S. State Info Number of Additional Breast Cancer Deaths Among Black Women, By State SOURCE: National ...

  15. Pseudomonal breast infection

    Science.gov (United States)

    Rastall, S; Catchpole, C; Bright-Thomas, R; Thrush, S

    2010-01-01

    Breast infection and breast sepsis secondary to Pseudomonas aeruginosa is uncommon. We report two cases of pseudomonal breast infection leading to septic shock and abscess formation in women with non-responding breast infection. The management of breast infection is broad-spectrum antibiotics and ultrasound with aspiration of any collection. To treat breast infection effectively, the causative organism must be isolated to enable appropriate antibiotic therapy. PMID:20412664

  16. Definitive diagnosis of breast implant rupture using magnetic resonance imaging.

    Science.gov (United States)

    Ahn, C Y; Shaw, W W; Narayanan, K; Gorczyca, D P; Sinha, S; Debruhl, N D; Bassett, L W

    1993-09-01

    Breast implant rupture is an important complication of augmented and reconstructed breasts. Although several techniques such as mammography, xeromammography, ultrasound, thermography, and computed tomographic (CT) scanning have been proven to be useful to detect implant rupture, they have several disadvantages and lack specificity. In the current study, we have established magnetic resonance imaging (MRI) as a definitive, reliable, and reproducible technique to diagnose both intracapsular and extracapsular ruptures. The study was conducted in 100 symptomatic patients. Our imaging parameters were able to identify ruptures in implants with silicone shells. All the ruptures showed the presence of wavy lines, free-floating silicone shell within the gel ("free-floating loose-thread sign" or "linguine sign"). We had a 3.75 percent incidence of false-positive and false-negative results. The sensitivity for detection of silicone implant rupture was 76 percent, with a specificity of 97 percent. In addition, we also were able to identify the artifacts that may interfere with the definitive diagnosis of implant rupture.

  17. Critical analysis of the images methods in detection and diagnosis in breast cancer

    International Nuclear Information System (INIS)

    Mendonca, Maria H.S.

    1995-01-01

    The female breast cancer is a relevant health issue among female population, due its incidence and remarkable effects in the biological, psychological and social levels. Its early diagnosis is important because it allows more effective treatments and enhances changes of cure, even allowing conservative surgical procedures. To make this possible it is essential the periodic breast imaging exams. The available imaging methods to date are: mammography, ultrasonography, thermography, nuclear medicine, computed tomography and MRI. All these methods have their advantages and disadvantages, applications and limitations and some are even in experimental stages. These methods must exercised in association to become more effective. Mammography is still, beyond and doubt the elected breast exam. even though imperfect. It must be performed repeatedly at periodic intervals depending upon the intrinsic conditions of the patient. The other methods complement the mammographic findings, clearing some of them. In this paper, the imaging methods available in our environmental for detected diagnosis of the early breast cancer are analyzed with emphasis in mammography and ultrasonography. Their advantages, disadvantages, indications and limitations are discussed. (author)

  18. Breast Reduction Surgery

    Science.gov (United States)

    ... considering breast reduction surgery, consult a board-certified plastic surgeon. It's important to understand what breast reduction surgery entails — including possible risks and complications — as ...

  19. Definition of a Twelve-Point Polygonal SAA Boundary for the GLAST Mission

    International Nuclear Information System (INIS)

    Djomehri, Sabra I.; UC, Santa Cruz; SLAC

    2007-01-01

    The Gamma-Ray Large Area Space Telescope (GLAST), set to launch in early 2008, detects gamma rays within a huge energy range of 100 MeV - 300 GeV. Background cosmic radiation interferes with such detection resulting in confusion over distinguishing cosmic from gamma rays encountered. This quandary is resolved by encasing GLAST's Large Area Telescope (LAT) with an Anti-Coincidence Detector (ACD), a device which identifies and vetoes charged particles. The ACD accomplishes this through plastic scintillator tiles; when cosmic rays strike, photons produced induce currents in Photomultiplier Tubes (PMTs) attached to these tiles. However, as GLAST orbits Earth at altitudes ∼550km and latitudes between -26 degree and 26 degree, it will confront the South Atlantic Anomaly (SAA), a region of high particle flux caused by trapped radiation in the geomagnetic field. Since the SAA flux would degrade the sensitivity of the ACD's PMTs over time, a determined boundary enclosing this region need be attained, signaling when to lower the voltage on the PMTs as a protective measure. The operational constraints on such a boundary require a convex SAA polygon with twelve edges, whose area is minimal ensuring GLAST has maximum observation time. The AP8 and PSB97 models describing the behavior of trapped radiation were used in analyzing the SAA and defining a convex SAA boundary of twelve sides. The smallest possible boundary was found to cover 14.58% of GLAST's observation time. Further analysis of defining a boundary safety margin to account for inaccuracies in the models reveals if the total SAA hull area is increased by ∼20%, the loss of total observational area is < 5%. These twelve coordinates defining the SAA flux region are ready for implementation by the GLAST satellite

  20. Bridge deck surface temperature monitoring by infrared thermography and inner structure identification using PPT and PCT analysis methods

    Science.gov (United States)

    Dumoulin, Jean

    2013-04-01

    One of the objectives of ISTIMES project was to evaluate the potentialities offered by the integration of different electromagnetic techniques able to perform non-invasive diagnostics for surveillance and monitoring of transport infrastructures. Among the EM methods investigated, we focused our research and development efforts on uncooled infrared camera techniques due to their promising potential level of dissemination linked to their relative low cost on the market. On the other hand, works were also carried out to identify well adapted implementation protocols and key limits of Pulse Phase Thermography (PPT) and Principal Component Thermography (PCT) processing methods to analyse thermal image sequence and retrieve information about the inner structure. So the first part of this research works addresses infrared thermography measurement when it is used in quantitative mode (not in laboratory conditions) and not in qualitative mode (vision applied to survey). In such context, it requires to process in real time thermal radiative corrections on raw data acquired to take into account influences of natural environment evolution with time, thanks to additional measurements. But, camera sensor has to be enough smart to apply in real time calibration law and radiometric corrections in a varying atmosphere. So, a complete measurement system was studied and developed [1] with low cost infrared cameras available on the market. In the system developed, infrared camera is coupled with other sensors to feed simplified radiative models running, in real time, on GPU available on small PC. The whole measurement system was implemented on the "Musmeci" bridge located in Potenza (Italy). No traffic interruption was required during the mounting of our measurement system. The infrared camera was fixed on top of a mast at 6 m elevation from the surface of the bridge deck. A small weather station was added on the same mast at 1 m under the camera. A GPS antenna was also fixed at the

  1. Infrared thermography based diagnosis of inter-turn fault and cooling system failure in three phase induction motor

    Science.gov (United States)

    Singh, Gurmeet; Naikan, V. N. A.

    2017-12-01

    Thermography has been widely used as a technique for anomaly detection in induction motors. International Electrical Testing Association (NETA) proposed guidelines for thermographic inspection of electrical systems and rotating equipment. These guidelines help in anomaly detection and estimating its severity. However, it focus only on location of hotspot rather than diagnosing the fault. This paper addresses two such faults i.e. inter-turn fault and failure of cooling system, where both results in increase of stator temperature. Present paper proposes two thermal profile indicators using thermal analysis of IRT images. These indicators are in compliance with NETA standard. These indicators help in correctly diagnosing inter-turn fault and failure of cooling system. The work has been experimentally validated for healthy and with seeded faults scenarios of induction motors.

  2. In situ assessment of structural timber elements of a historic building by infrared thermography and ultrasonic velocity

    Science.gov (United States)

    Kandemir-Yucel, A.; Tavukcuoglu, A.; Caner-Saltik, E. N.

    2007-01-01

    The infrared thermography (IRT) and the ultrasonic velocity measurements (UVM) promise to be particularly important to assess the state of deterioration and the adequacy of the boundary and microclimatic conditions for timber elements. These non-destructive methods supported by laboratory analyses of timber samples were conducted on a 13th century monument, Aslanhane Mosque in Ankara, Turkey. The combined interpretation of the results was done to assess the condition of structural timber elements in terms of their state of preservation, the dampness problems and the recent incompatible repairs affecting them. Results indicated that moist areas in the structure were associated with roof drainage problems and the repairs undertaken with cement-based mortars and plasters and oil-based paints. Juxtaposition of the IRT and UVM together with laboratory analyses was found to be useful to assess the soundness of timber, enhanced the accuracy and effectiveness of the survey and facilitated to build up the urgent and long-term conservation programs.

  3. A synchronized particle image velocimetry and infrared thermography technique applied to convective mass transfer in champagne glasses

    Science.gov (United States)

    Beaumont, Fabien; Liger-Belair, Gérard; Bailly, Yannick; Polidori, Guillaume

    2016-05-01

    In champagne glasses, it was recently suggested that ascending bubble-driven flow patterns should be involved in the release of gaseous carbon dioxide (CO2) and volatile organic compounds. A key assumption was that the higher the velocity of the upward bubble-driven flow patterns in the liquid phase, the higher the volume fluxes of gaseous CO2 desorbing from the supersaturated liquid phase. In the present work, simultaneous monitoring of bubble-driven flow patterns within champagne glasses and gaseous CO2 escaping above the champagne surface was performed, through particle image velocimetry and infrared thermography techniques. Two quite emblematic types of champagne drinking vessels were investigated, namely a long-stemmed flute and a wide coupe. The synchronized use of both techniques proved that the cloud of gaseous CO2 escaping above champagne glasses strongly depends on the mixing flow patterns found in the liquid phase below.

  4. [Fibrocystic breast disease--breast cancer sequence].

    Science.gov (United States)

    Habor, V; Habor, A; Copotoiu, C; Panţîru, A

    2010-01-01

    Fibrocystic breast disease has developed a major issue: the breast cancer sequence. Its involvement regarding the increse of breast cancer risk has 2 aspects: it may be either the marker of a prone tissue or a premalignant hystological deffect. Difficult differential diagnosis of benign proliferative breast lession and carcinoma led to the idea of sequency between the two: cancer does not initiate on normal mammary epithelia; it takes several proliferative stages for it to occur. In our series we analized a number of 677 breast surgical procedures where the pathologic examination reveals 115 cases (17%) of coexistence between cancer and fibrocystic breast disease. This aspect has proved to be related to earlier debut of breast cancer, suggesting that epithelial hyperplasia is a risk factor for breast cancer.

  5. New Eyes on the Universe Twelve Cosmic Mysteries and the Tools We Need to Solve Them

    CERN Document Server

    Webb, Stephen

    2012-01-01

    "New Eyes on the Universe -- Twelve Cosmic Mysteries and the Tools We Need to Solve Them" gives an up-to-date broad overview of some of the key issues in modern astronomy and cosmology. It describes the vast amount of observational data that the new generation of observatories and telescopes are currently producing, and how that data might solve some of the outstanding puzzles inherent in our emerging world view. Included are questions such as: What is causing the Universe to blow itself apart? What could be powering the luminous gamma-ray bursters? Where is all the matter in the Uni

  6. A novel double quad-inverter configuration for multilevel twelve-phase open-winding converter

    DEFF Research Database (Denmark)

    Padmanaban, Sanjeevi Kumar; Blaabjerg, Frede; Wheeler, Patrick William

    2016-01-01

    This paper describes a novel proposal of double quad-inverter configuration for multilevel twelve-phase open-winding ac converter. Modular power units are developed from reconfigured eight classical three-phase voltage source inverters (VSIs). Each VSI has one additional bi-directional switching...... numerical simulation software's (Matlab/PLECS) developments. Further, the results confirm the good agreement to the developed theoretical background. Proposed converter suits the need of low-voltage/high-current applications such as ac tractions and `More-Electric Aircraft' propulsion systems....

  7. Study of heat fluxes on plasma facing components in a tokamak from measurements of temperature by infrared thermography

    International Nuclear Information System (INIS)

    Daviot, R.

    2010-05-01

    The goal of this thesis is the development of a method of computation of those heat loads from measurements of temperature by infrared thermography. The research was conducted on three issues arising in current tokamaks but also future ones like ITER: the measurement of temperature on reflecting walls, the determination of thermal properties for deposits observed on the surface of tokamak components and the development of a three-dimensional, non-linear computation of heat loads. A comparison of several means of pyrometry, monochromatic, bi-chromatic and photothermal, is performed on an experiment of temperature measurement. We show that this measurement is sensitive to temperature gradients on the observed area. Layers resulting from carbon deposition by the plasma on the surface of components are modeled through a field of equivalent thermal resistance, without thermal inertia. The field of this resistance is determined, for each measurement points, from a comparison of surface temperature from infrared thermographs with the result of a simulation, which is based on a mono-dimensional linear model of components. The spatial distribution of the deposit on the component surface is obtained. Finally, a three-dimensional and non-linear computation of fields of heat fluxes, based on a finite element method, is developed here. Exact geometries of the component are used. The sensitivity of the computed heat fluxes is discussed regarding the accuracy of the temperature measurements. This computation is applied to two-dimensional temperature measurements of the JET tokamak. Several components of this tokamak are modeled, such as tiles of the divertor, upper limiter and inner and outer poloidal limiters. The distribution of heat fluxes on the surface of these components is computed and studied along the two main tokamak directions, poloidal and toroidal. Toroidal symmetry of the heat loads from one tile to another is shown. The influence of measurements spatial resolution

  8. High-definition infrared thermography of ice nucleation and propagation in wheat under natural frost conditions and controlled freezing.

    Science.gov (United States)

    Livingston, David P; Tuong, Tan D; Murphy, J Paul; Gusta, Lawrence V; Willick, Ian; Wisniewski, Micheal E

    2018-04-01

    An extremely high resolution infrared camera demonstrated various freezing events in wheat under natural conditions. Many of those events shed light on years of misunderstanding regarding freezing in small grains. Infrared thermography has enhanced our knowledge of ice nucleation and propagation in plants through visualization of the freezing process. The majority of infrared analyses have been conducted under controlled conditions and often on individual organs instead of whole plants. In the present study, high-definition (1280 × 720 pixel resolution) infrared thermography was used under natural conditions to visualize the freezing process of wheat plants during freezing events in 2016 and 2017. Plants within plots were found to freeze one at a time throughout the night and in an apparently random manner. Leaves on each plant also froze one at a time in an age-dependent pattern with oldest leaves freezing first. Contrary to a common assumption that freezing begins in the upper parts of leaves; freezing began at the base of the plant and spread upwards. The high resolution camera used was able to verify that a two stage sequence of freezing began within vascular bundles. Neither of the two stages was lethal to leaves, but a third stage was demonstrated at colder temperatures that was lethal and was likely a result of dehydration stress; this stage of freezing was not detectable by infrared. These results underscore the complexity of the freezing process in small grains and indicate that comprehensive observational studies are essential to identifying and selecting freezing tolerance traits in grain crops.

  9. Infrared thermography--a non-invasive tool to evaluate thermal status of neonatal pigs based on surface temperature.

    Science.gov (United States)

    Kammersgaard, T S; Malmkvist, J; Pedersen, L J

    2013-12-01

    Hypothermia is a major cause of mortality in neonatal pigs. Infrared (IR) thermography is a promising non-invasive method to assess thermal status, but has not been evaluated for use on neonatal pigs from birth. The aim of this study was to evaluate the application of IR thermography as a non-invasive tool to estimate body temperature and assess the thermal status in newborn pigs by (1) estimating the relationship between surface temperature and rectal temperature (RT) in neonatal pigs; and (2) estimating the influence of air temperature (AT), birth weight and the time from birth on the relationship between surface temperature and RT. The method was evaluated on the basis of 1695 thermograms and 915 RTs on 91 neonatal pigs born in loose farrowing pens with floor heating at 34°C, and three different ATs (15°C, 20°C and 25°C). Full-body thermograms of the back and the side of the pigs and RT were acquired at 11 sampling times between birth and 48 h after birth. The maximum (IRmax), minimum, average of the full body and ear minimum IR surface temperatures were derived from the thermograms. IRmax had the highest correlation with RT (0.82) and was therefore used in the statistical analysis. The relation of RT by IRmax depended on time at: 0 h (slope: 0.20°C, Pmethod has the potential to be used without the need for manual restraint of the pigs. On the basis of the results of this study, we propose that IRmax temperature from full-body thermograms has implication as a valid tool to assess the thermal status in neonatal piglets but not as an identical substitute for RT.

  10. Determination of thermal diffusivity of dental enamel and dentin as a function of temperature, using infrared thermography

    International Nuclear Information System (INIS)

    Pereira, Thiago Martini

    2009-01-01

    In this work it was developed a software that calculates automatically, the thermal diffusivity value as a function of temperature in materials. The infrared thermography technique was used for data acquisition of temperature distribution as a function of time. These data were used to adjust a temperature function obtained from the homogeneous heat equation with specific boundary conditions. For that, an infrared camera (detecting from 8 μm to 9 μm) was calibrated to detect temperature ranging from 185 degree C up to 1300 degree C at an acquisition rate of 300 Hz. It was used, 10 samples of dental enamel and 10 samples of dentin, with 4 mm x 4 mm x 2 mm, which were obtained from bovine lower incisor teeth. These samples were irradiated with an Er:Cr:YSGG pulsed laser (λ = 2,78 μm). The resulting temperature was recorded 2 s prior, 10 s during irradiation and continuing for 2 more seconds after it. After each irradiation, all obtained thermal images were processed in the software, creating a file with the data of thermal diffusivity as a function of temperature. Another file with the thermal diffusivity values was also calculated after each laser pulse. The mean result of thermal diffusivity obtained for dental enamel was 0,0084 ± 0,001 cm2/s for the temperature interval of 220-550 degree C. The mean value for thermal diffusivity obtained for dentin was 0,0015 0,0004 cm2/s in temperatures up to 360 degree C; however, this value increases for higher temperatures. According to these results, it was possible to conclude that the use of infrared thermography, associated with the software developed in this work, is an efficient method to determine the thermal diffusivity values as a function of temperature in different materials. (author)

  11. Identification of thermal properties distribution in building wall using infrared thermography

    Science.gov (United States)

    Brouns, Jordan; Dumoulin, Jean

    2016-04-01

    [1] L. Ibos, J-P. Monchau, V. Feuillet, Y. Candau, A comparative study of in-situ measurement methods of a building wall thermal resistance using infrared thermography, in Proc. SPIE 9534, Twelfth International Conference on Quality Control by Artificial Vision 2015, 95341I (April 30, 2015); doi:10.1117/12.2185126 [2] Nassiopoulos, A., Bourquin, F., On-site building walls characterization, Numerical Heat Transfer, Part A : Applications, 63(3) :179 :200, 2013 [3] J. Brouns, Développement d'outils numériques pour l'audit énergétique des bâtiments, PhD thesis, Université Paris-Est, SIE, 2014 [4] J.-L. Lions, Contrôle optimal de systèmes gouvernés par des équations aux dérivées partielles. Book, Dunod editor, 1968.

  12. Breast cancer in men

    Science.gov (United States)

    ... in situ - male; Intraductal carcinoma - male; Inflammatory breast cancer - male; Paget disease of the nipple - male; Breast cancer - male ... The cause of breast cancer in men is not clear. But there are risk factors that make breast cancer more likely in men: Exposure to ...

  13. Breast Cancer Overview

    Science.gov (United States)

    ... are here Home > Types of Cancer > Breast Cancer Breast Cancer This is Cancer.Net’s Guide to Breast Cancer. Use the menu below to choose the Overview/ ... social workers, and patient advocates. Cancer.Net Guide Breast Cancer Introduction Statistics Medical Illustrations Risk Factors and Prevention ...

  14. Breast Cancer -- Male

    Science.gov (United States)

    ... Home > Types of Cancer > Breast Cancer in Men Breast Cancer in Men This is Cancer.Net’s Guide to Breast Cancer in Men. Use the menu below to choose ... social workers, and patient advocates. Cancer.Net Guide Breast Cancer in Men Introduction Statistics Risk Factors and Prevention ...

  15. Work environment perceptions following relocation to open-plan offices: A twelve-month longitudinal study.

    Science.gov (United States)

    Bergström, Jessica; Miller, Michael; Horneij, Eva

    2015-01-01

    A workplace's design can have various positive or negative effects on the employees and since the 1970s the advantages and disadvantages of open-plan offices have been discussed. The aim of this study was to investigate perceived health, work environment and self-estimated productivity one month before and at three, six and twelve months after relocation from individual offices to an open-plan office environment. Employees from three departments within the same company group and who worked with relatively similar tasks and who were planned to be relocated from private offices to open-plan offices were invited to participate. Questionnaires comprising items from The Salutogenic Health Indicator Scale, The Work Experience Measurement Scale, the questionnaire by Brennan et al. about perceived performance and one question from the Work Ability Index were sent to participants one month before relocation (baseline) to open-plan offices and then at three, six and twelve months after relocation. At baseline, 82 questionnaires were sent out. The response rate was 85%. At the follow-ups 77-79 questionnaires were sent out and the response-rate was 70%-81%. At follow-ups, perceived health, job satisfaction and performance had generally deteriorated. The results of the study indicate that employees' perception of health, work environment and performance decreased during a 12 month period following relocation from individual offices to open-plan offices.

  16. Twelve fundamental life histories evolving through allocation-dependent fecundity and survival.

    Science.gov (United States)

    Johansson, Jacob; Brännström, Åke; Metz, Johan A J; Dieckmann, Ulf

    2018-03-01

    An organism's life history is closely interlinked with its allocation of energy between growth and reproduction at different life stages. Theoretical models have established that diminishing returns from reproductive investment promote strategies with simultaneous investment into growth and reproduction (indeterminate growth) over strategies with distinct phases of growth and reproduction (determinate growth). We extend this traditional, binary classification by showing that allocation-dependent fecundity and mortality rates allow for a large diversity of optimal allocation schedules. By analyzing a model of organisms that allocate energy between growth and reproduction, we find twelve types of optimal allocation schedules, differing qualitatively in how reproductive allocation increases with body mass. These twelve optimal allocation schedules include types with different combinations of continuous and discontinuous increase in reproduction allocation, in which phases of continuous increase can be decelerating or accelerating. We furthermore investigate how this variation influences growth curves and the expected maximum life span and body size. Our study thus reveals new links between eco-physiological constraints and life-history evolution and underscores how allocation-dependent fitness components may underlie biological diversity.

  17. Comparative analysis and supragenome modeling of twelve Moraxella catarrhalis clinical isolates.

    Science.gov (United States)

    Davie, Jeremiah J; Earl, Josh; de Vries, Stefan P W; Ahmed, Azad; Hu, Fen Z; Bootsma, Hester J; Stol, Kim; Hermans, Peter W M; Wadowsky, Robert M; Ehrlich, Garth D; Hays, John P; Campagnari, Anthony A

    2011-01-26

    M. catarrhalis is a gram-negative, gamma-proteobacterium and an opportunistic human pathogen associated with otitis media (OM) and exacerbations of chronic obstructive pulmonary disease (COPD). With direct and indirect costs for treating these conditions annually exceeding $33 billion in the United States alone, and nearly ubiquitous resistance to beta-lactam antibiotics among M. catarrhalis clinical isolates, a greater understanding of this pathogen's genome and its variability among isolates is needed. The genomic sequences of ten geographically and phenotypically diverse clinical isolates of M. catarrhalis were determined and analyzed together with two publicly available genomes. These twelve genomes were subjected to detailed comparative and predictive analyses aimed at characterizing the supragenome and understanding the metabolic and pathogenic potential of this species. A total of 2383 gene clusters were identified, of which 1755 are core with the remaining 628 clusters unevenly distributed among the twelve isolates. These findings are consistent with the distributed genome hypothesis (DGH), which posits that the species genome possesses a far greater number of genes than any single isolate. Multiple and pair-wise whole genome alignments highlight limited chromosomal re-arrangement. M. catarrhalis gene content and chromosomal organization data, although supportive of the DGH, show modest overall genic diversity. These findings are in stark contrast with the reported heterogeneity of the species as a whole, as wells as to other bacterial pathogens mediating OM and COPD, providing important insight into M. catarrhalis pathogenesis that will aid in the development of novel therapeutic regimens.

  18. Primary anaplastic large cell lymphoma of the breast arising in reconstruction mammoplasty capsule of saline filled breast implant after radical mastectomy for breast cancer: an unusual case presentation

    Directory of Open Access Journals (Sweden)

    Sur Monalisa

    2009-04-01

    Full Text Available Abstract Background Primary non-Hodgkin lymphoma (NHL of the breast represents 0.04–0.5% of malignant lesions of the breast and accounts for 1.7–2.2% of extra-nodal NHL. Most primary cases are of B-cell phenotype and only rare cases are of T-cell phenotype. Anaplastic large cell lymphoma (ALCL is a rare T-cell lymphoma typically seen in children and young adults with the breast being one of the least common locations. There are a total of eleven cases of primary ALCL of the breast described in the literature. Eight of these cases occurred in proximity to breast implants, four in relation to silicone breast implant and three in relation to saline filled breast implant with three out of the eight implant related cases having previous history of breast cancer treated surgically. Adjuvant postoperative chemotherapy is given in only one case. Secondary hematological malignancies after breast cancer chemotherapy have been reported in literature. However in contrast to acute myeloid leukemia (AML, the association between lymphoma and administration of chemotherapy has never been clearly demonstrated. Case Presentation In this report we present a case of primary ALCL of the breast arising in reconstruction mamoplasty capsule of saline filled breast implant after radical mastectomy for infiltrating ductal carcinoma followed by postoperative chemotherapy twelve years ago. Conclusion Primary ALK negative ALCL arising at the site of saline filled breast implant is rare. It is still unclear whether chemotherapy and breast implantation increases risk of secondary hematological malignancies significantly. However, it is important to be aware of these complications and need for careful pathologic examination of tissue removed for implant related complications to make the correct diagnosis for further patient management and treatment. It is important to be aware of this entity at this site as it can be easily misdiagnosed on histologic grounds and to exclude

  19. Comparative assay of fluorescent antibody test results among twelve European National Reference Laboratories using various anti-rabies conjugates

    DEFF Research Database (Denmark)

    Robardet, E.; Andrieu, S.; Rasmussen, Thomas Bruun

    2013-01-01

    Twelve National Reference Laboratories (NRLs) for rabies have undertaken a comparative assay to assess the comparison of fluorescent antibody test (FAT) results using five coded commercial anti-rabies conjugates (Biorad, Bioveta, Fujirebio, Millipore, and SIFIN conjugates). Homogenized positive...

  20. Breast cancer diagnosis by thermal imaging in the fields of medical and artificial intelligence sciences: review article

    Directory of Open Access Journals (Sweden)

    Hossein Ghayoumi Zadeh

    2016-09-01

    Full Text Available Breast cancer is the most common cancer in women and one of the leading of death among them. The high and increasing incidence of the disease and its difficult treatment specifically in advanced stages, imposes hard situations for different countries’ health systems. Body temperature is a natural criteria for the diagnosis of diseases. In recent decades extensive research has been conducted to increase the use of thermal cameras and obtain a close relationship between heat and temperature of the skin's physiology. Thermal imaging (thermography applies infrared method which is fast, non-invasive, non-contact and flexibile to monitor the temperature of the human body. This paper investigates highly diversified studies implemented before and after the year 2000. And it emphasizes mostly on the newely published articles including: performance and evaluation of thermal imaging, the various aspects of imaging as well as The available technology in this field and its disadvantages in the diagnosis of breast cancer. Thermal imaging has been adopted by researchers in the fields of medicine and biomedical engineering for the diagnosis of breast cancer. With the advent of modern infrared cameras, data acquisition and processing techniques, it is now possible to have real time high resolution thermographic images, which is likely to surge further research in this field.  Thermography does not provide information on the structures of the breast morphology, but it provides performance information of temperature and breast tissue vessels. It is assumed that the functional changes occured before the start of the structural changes which is the result of disease or cancer. These days, thermal imaging method has not been established as an applicative method for screening or diagnosing purposes in academic centers. But there are different centers that adopt this method for the diognosis and examining purposes. Thermal imaging is an effective method which is

  1. USE OF CORTICAL BONE FENESTRATION, AUTOGENOUS FREE SKIN GRAFT, AND THERMOGRAPHY FOR WOUND TREATMENT AND MONITORING IN A RED WOLF (CANIS RUFUS GREGORYI).

    Science.gov (United States)

    Hurley-Sanders, Jennifer L; Sladky, Kurt K; Nolan, Elizabeth C; Loomis, Michael R

    2015-09-01

    A 2-yr-old female red wolf (Canis rufus gregoryi) sustained a degloving injury to the left thoracic limb while in a display habitat. Initial attempts to resolve the extensive wound by using conservative measures were unsuccessful. Subsequent treatment using a free skin graft consisted first of establishment of an adequate granulation bed via cortical bone fenestration. After establishment of a healthy granulation bed was achieved, free skin graft was harvested and transposed over the bed. To monitor viability and incorporation of the graft, serial thermographic imaging was performed. Thermography noninvasively detects radiant heat patterns and can be used to assess vascularization of tissue, potentially allowing early detection of graft failure. In this case, thermography documented successful graft attachment.

  2. Application of thermography to assess the adequacy training in elite athletes; Aplicacion de la termografia para valorar la adecuacion del entrenamiento en deportistas de elite

    Energy Technology Data Exchange (ETDEWEB)

    Jover, A.; Salvador, R.; Cibrian, R.; Gonzalez-Pena, R.; Minguez, M. F.; Pino, L.; Lopez de la O, F. J.; Guillen, J.; Reinado, D.; Cortina, T.; Chinillach, N.; Dalmases, F.; Romero, C.; Martinez-Celorio, R.; Diez, S.; Rosello, J.; Reinado, D.; Cortina, T.; Chinillach, N.; Dalmases, F.; Romero, C.; Martinez-Celorio, R.; Diez, S.; Rosello, J.

    2011-07-01

    Thermography is a technique that allows to know the body surface temperature by infrared radiation, making it a completely non-invasive technique, without physical contact. The differences in body temperature in different parts of the body naturally shown in the thermo gram and given that sport can alter the temperature distribution is imaging technique can help to analyze the effect of training on muscle and determine if it has been appropriate and correct.

  3. The twelve-flavor β-function and dilaton tests of the sextet scalar

    Directory of Open Access Journals (Sweden)

    Fodor Zoltan

    2018-01-01

    Full Text Available We discuss near-conformal gauge theories beyond the standard model (BSM where interesting results on the twelve-flavor β-function of massless fermions in the fundamental representation of the SU(3 color gauge group and dilaton tests of the light scalar with two massless fermions in the two-index symmetric tensor (sextet representation can be viewed as parts of the same BSM paradigm under investigation. The clear trend in the decreasing size of β-functions at fixed renormalized gauge coupling is interpreted as a first indicator how the conformal window (CW is approached in correlation with emergent near-conformal light scalars. BSM model building close to the CW will be influenced by differing expectations on the properties of the emergent light 0++ scalar either as a σ-particle of chiral symmetry breaking (ΧS B, or as a dilaton of scale symmetry breaking. The twelve-flavor β-function emerges as closest to the CW, perhaps near-conformal, or perhaps with an infrared fixed point (IRFP at some unexplored strong coupling inside the CW. It is premature to speculate on dilaton properties of the twelveflavor model since the near-conformal realization remains an open question. However, it is interesting and important to investigate dilaton tests of the light sextet scalar whose β-function is closest to the CW in the symmetry breaking phase and emerges as the leading candidate for dilaton tests of the light scalar. We report results from high precision analysis of the twelve-flavor β-function [1] refuting its published IRFP [2, 3]. We present our objections to recent claims [4, 5] for non-universal behavior of staggered fermions used in our analysis. We also report our first analysis of dilaton tests of the light 0++ scalar in the sextet model and comment on related post-conference developments. The dilaton test is the main thrust of this conference contribution including presentation #405 on the nf = 12 β-function and presentation #260 on dilaton

  4. Combining Magnetic Resonance Imaging (MRI) and Medical Infrared Thermography (MIT) in the pre- and per-operating management of severe Hidradenitis Suppurativa (HS).

    Science.gov (United States)

    Derruau, Stéphane; Renard, Yohann; Pron, Hervé; Taiar, Redha; Abdi, Ellie; Polidori, Guillaume; Lorimier, Sandrine

    2018-05-12

    Hidradenitis suppurativa (HS) is a chronic, inflammatory, and recurrent skin disease. Surgical excision of wounds appears to be the only curative treatment for the prevention of recurrence of moderate to severe stages. Magnetic resonance imaging (MRI) is a standard reference examination for the detection of HS peri-anal inflammatory fistula. In this case study, the use of real-time medical infrared thermography, in combination with MRI as appropriate imaging, is proposed. The aim is to assist surgeons in the pre- and peri-surgical management of severe perianal hidradenitis suppurativa with the intent to ensure that all diseased lesions were removed during surgery and therefore to limit recurrence. The results show that medical infrared thermography (MIT), coupled with MRI, could be highly effective strategy to address thermally distinguished health tissues and inflammatory sites during excision, as characterised by differential increases in temperature. Medical infrared thermography could be used to check the total excision of inflammatory lesions as a noninvasive method that is not painful, not radiant, and is easily transportable during surgery. Ultimately, this method could be complementary with MRI in providing clinicians with objective data on the status of tissues below the perianal skin surface in the pre- and per-operating management of severe hidradenitis suppurativa. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Improvement of energy efficiency: the use of thermography and air-tightness test in verification of thermal performance of school buildings

    Science.gov (United States)

    Kauppinen, Timo; Siikanen, Sami

    2011-05-01

    The improvement of energy efficiency is the key issue after the energy performance of buildings directive came into the force in European Union countries. The city of Kuopio participate a project, in which different tools will be used, generated and tested to improve the energy efficiency of public buildings. In this project there are 2 schools, the other consuming much more heating energy than the other same type of school. In this paper the results of the thermography in normal conditions and under 50 Pa pressure drop will be presented; as well as the results of remote controlled air tightness test of the buildings. Thermography combined with air tightness test showed clearly the reasons of specific consumption differences of heating energy - also in the other hand, the measurements showed the problems in the performance of ventilation system. Thermography, air tightness test and other supporting measurements can be used together to solve energy loss problems - if these measurements will be carried out by proper way.

  6. Mid-infrared thermal imaging for an effective mapping of surface materials and sub-surface detachments in mural paintings: integration of thermography and thermal quasi-reflectography

    Science.gov (United States)

    Daffara, C.; Parisotto, S.; Mariotti, P. I.

    2015-06-01

    Cultural Heritage is discovering how precious is thermal analysis as a tool to improve the restoration, thanks to its ability to inspect hidden details. In this work a novel dual mode imaging approach, based on the integration of thermography and thermal quasi-reflectography (TQR) in the mid-IR is demonstrated for an effective mapping of surface materials and of sub-surface detachments in mural painting. The tool was validated through a unique application: the "Monocromo" by Leonardo da Vinci in Italy. The dual mode acquisition provided two spatially aligned dataset: the TQR image and the thermal sequence. Main steps of the workflow included: 1) TQR analysis to map surface features and 2) to estimate the emissivity; 3) projection of the TQR frame on reference orthophoto and TQR mosaicking; 4) thermography analysis to map detachments; 5) use TQR to solve spatial referencing and mosaicking for the thermal-processed frames. Referencing of thermal images in the visible is a difficult aspect of the thermography technique that the dual mode approach allows to solve in effective way. We finally obtained the TQR and the thermal maps spatially referenced to the mural painting, thus providing the restorer a valuable tool for the restoration of the detachments.

  7. Breast Reconstruction with Flap Surgery

    Science.gov (United States)

    ... augmented with a breast implant to achieve the desired breast size. Surgical methods Autologous tissue breast reconstruction ... as long as a year or two before feeling completely healed and back to normal. Future breast ...

  8. Stages of Male Breast Cancer

    Science.gov (United States)

    ... Breast & Gynecologic Cancers Breast Cancer Screening Research Male Breast Cancer Treatment (PDQ®)–Patient Version General Information about Male Breast Cancer Go to Health Professional Version Key Points Male ...

  9. Twelve recommendations for integrating existing systematic reviews into new reviews: EPC guidance.

    Science.gov (United States)

    Robinson, Karen A; Chou, Roger; Berkman, Nancy D; Newberry, Sydne J; Fu, Rongwei; Hartling, Lisa; Dryden, Donna; Butler, Mary; Foisy, Michelle; Anderson, Johanna; Motu'apuaka, Makalapua; Relevo, Rose; Guise, Jeanne-Marie; Chang, Stephanie

    2016-02-01

    As time and cost constraints in the conduct of systematic reviews increase, the need to consider the use of existing systematic reviews also increases. We developed guidance on the integration of systematic reviews into new reviews. A workgroup of methodologists from Evidence-based Practice Centers developed consensus-based recommendations. Discussions were informed by a literature scan and by interviews with organizations that conduct systematic reviews. Twelve recommendations were developed addressing selecting reviews, assessing risk of bias, qualitative and quantitative synthesis, and summarizing and assessing body of evidence. We provide preliminary guidance for an efficient and unbiased approach to integrating existing systematic reviews with primary studies in a new review. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Twelve Tips for teaching medical professionalism at all levels of medical education.

    Science.gov (United States)

    Al-Eraky, Mohamed Mostafa

    2015-01-01

    Review of studies published in medical education journals over the last decade reveals that teaching medical professionalism is essential, yet challenging. According to a recent Best Evidence in Medical Education (BEME) guide, there is no consensus on a theoretical or practical model to integrate the teaching of professionalism into medical education. The aim of this article is to outline a practical manual for teaching professionalism at all levels of medical education. Drawing from research literature and author's experience, Twelve Tips are listed and organised in four clusters with relevance to (1) the context, (2) the teachers, (3) the curriculum, and (4) the networking. With a better understanding of the guiding educational principles for teaching medical professionalism, medical educators will be able to teach one of the most challenging constructs in medical education.

  11. Twelve tips for developing and delivering a massive open online course in medical education.

    Science.gov (United States)

    Pickering, James D; Henningsohn, Lars; DeRuiter, Marco C; de Jong, Peter G M; Reinders, Marlies E J

    2017-07-01

    Massive open online courses (MOOCs) are a novel mode of online learning. They are typically based on higher education courses and can attract a high number of learners, often in the thousands. They are distinct from on-campus education and deliver the learning objectives through a series of short videos, recommended readings and discussion fora, alongside automated assessments. Within medical education the role of MOOCs remains unclear, with recent proposals including continuing professional development, interprofessional education or integration into campus-based blended learning curricula. In this twelve tips article, we aim to provide a framework for readers to use when developing, delivering and evaluating a MOOC within medical education based on the literature and our own experience. Practical advice is provided on how to design the appropriate curriculum, engage with learners on the platform, select suitable assessments, and comprehensively evaluate the impact of your course.

  12. Hepatoprotective activity of twelve novel 7'-hydroxy lignan glucosides from Arctii Fructus.

    Science.gov (United States)

    Yang, Ya-Nan; Huang, Xiao-Ying; Feng, Zi-Ming; Jiang, Jian-Shuang; Zhang, Pei-Cheng

    2014-09-17

    Twelve novel 7'-hydroxy lignan glucosides (1-12), including two benzofuran-type neolignans, two 8-O-4' neolignans, two dibenzylbutyrolactone lignans, and six tetrahydrofuranoid lignans, together with six known lignan glucosides (13-18), were isolated from the fruit of Arctium lappa L. (Asteraceae), commonly known as Arctii Fructus. Their structures were elucidated using spectroscopy (1D and 2D NMR, MS, IR, ORD, and UV) and on the basis of chemical evidence. The absolute configurations of compounds 1-12 were confirmed using rotating frame nuclear overhauser effect spectroscopy (ROESY), the circular dichroic (CD) exciton chirality method, and Rh2(OCOCF3)4-induced CD spectrum analysis. All of the isolated compounds were tested for hepatoprotective effects against D-galactosamine-induced cytotoxicity in HL-7702 hepatic cells. Compounds 1, 2, 7-12, and 17 showed significantly stronger hepatoprotective activity than the positive control bicyclol at a concentration of 1 × 10(-5) M.

  13. [Longitudinal genetic effects on mandibular position of female twins from six to twelve years old].

    Science.gov (United States)

    Zhu, Chang-feng; Peng, Jing

    2013-06-01

    To find the longitudinal genetic effects on mandibular position in mixed dentition. The sample used in this study consisted of lateral cephalograms of eighty-nine pairs of female twins in Beijing. With a mixed longitudinal method, the effective twins were 183 pairs(monozygous 110 pairs and dizygous 73 ones). The genetic and environmental effects on mandibular position were analyzed by statistical methods in female twins from six to twelve years old. Statistical comparisons revealed significant (Pchin is the most subjective to environment change, then the mandibular angle, and the condyle is the least. Using N and S as references, the environmental influence on heights showed different order from the most to least changeable: The mandibular angle, the condyle and the chin. In later stage of our observation, the mandibular morphology and growth type might be family inherited. For environmental influences plays important roles on mandibular position, these findings can be used in orthodontic treatment planning.

  14. Exploring Content Schemata Influence on L2 Reading: The Hunted Fox and Twelve and Not Stupid

    Directory of Open Access Journals (Sweden)

    Amizura Hanadi Mohd Radzi

    2014-10-01

    Full Text Available This paper will discuss the aspects of content schemata in second language reading among diploma level students who were taking a reading course in Universiti Teknologi MARA Perlis. In this qualitative case study, the researcher had selected two short stories that are categorized as content-familiar texts, i.e. The Hunted Fox and Twelve and Not Stupid. Six participants were asked to write a 150-word entry response on the short story and a grading criteria was used to assess the participants’ level of comprehension. An in-depth interview was also conducted on each participant. The entry responses and the interview patterns were analyzed to determine whether content schemata had contributed to the learners’ understanding of the text. This study discovered that content schemata had contributed to the learners’ understanding of the text because the learners’ comprehension was facilitated by their background knowledge on the content-familiar texts.

  15. Development of twelve microsatellite loci in the red tree corals Primnoa resedaeformis and Primnoa pacifica

    Science.gov (United States)

    Morrison, Cheryl L.; Springmann, Marcus J.; Shroades, Kelsey; Stone, Robert P.

    2015-01-01

    A suite of tetra-, penta-, and hexa-nucleotide microsatellite loci were developed from Roche 454 pyrosequencing data for the cold-water octocorals Primnoa resedaeformis and P. pacifica. Twelve of 98 primer sets tested consistently amplified in 30 P. resedaeformis samples from Baltimore Canyon (western North Atlantic Ocean) and in 24 P. pacifica samples (Shutter Ridge, eastern Gulf of Alaska). The loci displayed moderate levels of allelic diversity (average 7.5 alleles/locus) and heterozygosity (average 47 %). Levels of genetic diversity were sufficient to produce unique multi-locus genotypes and to distinguish species. These common species are long-lived (hundreds of years) and provide essential fish habitat (P. pacifica), yet populations are provided little protection from human activities. These loci will be used to determine regional patterns of population connectivity to inform effective marine spatial planning and ecosystem-based fisheries management.

  16. Twelve tips for teaching child development and disability to medical students.

    Science.gov (United States)

    McDonald, Jenny

    2018-02-01

    Child development is a marker of well-being in childhood and recognition of developmental delay allows timely investigation and intervention for children with developmental disabilities. Despite this, child development and disabilities are not given emphasis in the medical curriculum. This under representation of teaching combined with the stigma associated with disabilities contributes to the sub-optimal health care of people with disabilities. As well as, addressing the stigma of disability a medical undergraduate curriculum should include: the key concepts of child development; the clinical presentation of the most common developmental disabilities; developmental history taking and the infant neurodevelopmental examination. The following twelve tips provide practical advice about how to teach this knowledge and these skills during medical training.

  17. Comparative analysis and supragenome modeling of twelve Moraxella catarrhalis clinical isolates

    Directory of Open Access Journals (Sweden)

    Hermans Peter WM

    2011-01-01

    Full Text Available Abstract Background M. catarrhalis is a gram-negative, gamma-proteobacterium and an opportunistic human pathogen associated with otitis media (OM and exacerbations of chronic obstructive pulmonary disease (COPD. With direct and indirect costs for treating these conditions annually exceeding $33 billion in the United States alone, and nearly ubiquitous resistance to beta-lactam antibiotics among M. catarrhalis clinical isolates, a greater understanding of this pathogen's genome and its variability among isolates is needed. Results The genomic sequences of ten geographically and phenotypically diverse clinical isolates of M. catarrhalis were determined and analyzed together with two publicly available genomes. These twelve genomes were subjected to detailed comparative and predictive analyses aimed at characterizing the supragenome and understanding the metabolic and pathogenic potential of this species. A total of 2383 gene clusters were identified, of which 1755 are core with the remaining 628 clusters unevenly distributed among the twelve isolates. These findings are consistent with the distributed genome hypothesis (DGH, which posits that the species genome possesses a far greater number of genes than any single isolate. Multiple and pair-wise whole genome alignments highlight limited chromosomal re-arrangement. Conclusions M. catarrhalis gene content and chromosomal organization data, although supportive of the DGH, show modest overall genic diversity. These findings are in stark contrast with the reported heterogeneity of the species as a whole, as wells as to other bacterial pathogens mediating OM and COPD, providing important insight into M. catarrhalis pathogenesis that will aid in the development of novel therapeutic regimens.

  18. Supportive care during treatment for breast cancer: resource allocations in low- and middle-income countries. A Breast Health Global Initiative 2013 consensus statement.

    Science.gov (United States)

    Cardoso, Fatima; Bese, Nuran; Distelhorst, Sandra R; Bevilacqua, Jose Luiz B; Ginsburg, Ophira; Grunberg, Steven M; Gralla, Richard J; Steyn, Ann; Pagani, Olivia; Partridge, Ann H; Knaul, Felicia Marie; Aapro, Matti S; Andersen, Barbara L; Thompson, Beti; Gralow, Julie R; Anderson, Benjamin O

    2013-10-01

    Breast cancer patients may have unmet supportive care needs during treatment, including symptom management of treatment-related toxicities, and educational, psychosocial, and spiritual needs. Delivery of supportive care is often a low priority in low- and middle-income settings, and is also dependent on resources available. This consensus statement describes twelve key recommendations for supportive care during treatment in low- and middle-income countries, identified by an expert international panel as part of the 5th Breast Health Global Initiative (BHGI) Global Summit for Supportive Care, which was held in October 2012, in Vienna, Austria. Panel recommendations are presented in a 4-tier resource-stratified table to illustrate how health systems can provide supportive care services during treatment to breast cancer patients, starting at a basic level of resource allocation and incrementally adding program resources as they become available. These recommendations include: health professional and patient and family education; management of treatment related toxicities, management of treatment-related symptoms of fatigue, insomnia and non-specific pain, and management of psychosocial and spiritual issues related to breast cancer treatment. Establishing supportive care during breast cancer treatment will help ensure that breast cancer patients receive comprehensive care that can help 1) improve adherence to treatment recommendations, 2) manage treatment-related toxicities and other treatment related symptoms, and 3) address the psychosocial and spiritual aspects of breast cancer and breast cancer treatments. Copyright © 2013 The Authors. Published by Elsevier Ltd.. All rights reserved.

  19. Breast development and anatomy.

    Science.gov (United States)

    Pandya, Sonali; Moore, Richard G

    2011-03-01

    In this article, the development of the female breast, as well as the functional anatomy, blood supply, innervation and lymphatic drainage are described. A thorough understanding of the breast anatomy is an important adjunct to a meticulous clinical breast examination. Breast examination is a complex skill involving key maneuvers, including careful inspection and palpation. Clinical breast examination can provide an opportunity for the clinician to educate patients about their breast and about breast cancer, its symptoms, risk factors, early detection, and normal breast composition, and specifically variability. Clinical breast examination can help to detect some cancers not found by mammography, and clinicians should not override their examination findings if imaging is not supportive of the physical findings.

  20. Dense Breasts: Answers to Commonly Asked Questions

    Science.gov (United States)

    ... Cancer Prevention Genetics of Breast & Gynecologic Cancers Breast Cancer Screening Research Dense Breasts: Answers to Commonly Asked Questions What are dense breasts? Breasts contain glandular, connective, and fat tissue. Breast density is a term that describes the ...

  1. Phenotypically divergent classification of preweaned heifer calves for feed efficiency indexes and their correlations with heat production and thermography.

    Science.gov (United States)

    Leão, J M; Coelho, S G; Machado, F S; Azevedo, R A; Lima, J A M; Carneiro, J C; Lage, C F A; Ferreira, A L; Pereira, L G R; Tomich, T R; Campos, M M

    2018-03-07

    The aims of this study were (1) to assess if there is phenotypical divergence for feed efficiency (FE) during the preweaning phase; (2) if FE is correlated with heat production (HP) measured by the face mask method or (3) by surface skin temperature via thermography, and (4) whether these methods are applicable to preweaned calves. Holstein × Gyr heifer calves (n = 36, birth body weight = 32.4 ± 6.6 kg) were enrolled and on trial between 4 and 12 wk of age and were classified into 2 residual feed intake (RFI) and residual body weight gain (RG) groups: high efficiency (HE; RFI, n = 10; and RG, n = 9) and low efficiency (LE; RFI, n = 10; and RG, n = 8). Calves were fed milk (6 L/d) and solid feed (95% starter and 5% chopped Tifton 85 hay, as fed). Growth was monitored weekly and feed intake (milk and solid feed) daily, during the whole period. Gas exchanges (O 2 consumption and production of CO 2 and CH 4 ) were obtained using a face mask at 45 ± 5 d of age and HP was estimated. Maximum temperatures were measured at 7 sites with an infrared camera at 62 ± 7 d of age. There was divergence in RFI and RG. Respectively, HE and LE calves had RFI of -0.14 and 0.13 kg/d, and RG of 0.05 and -0.07 kg/d. Dry matter intake was 15% lower in HE-RFI compared with LE-RFI, but no differences were observed in average daily weight gain. Within the RG test, no differences were observed in dry matter intake or average daily gain. The HE-RFI calves consumed less O 2 (L/d) and produced less CO 2 (L/d). Heart rate and HP were lower for HE-RFI calves compared with LE-RFI. Residual feed intake was correlated with HP (r = 0.48), O 2 consumption (r = 0.48), CO 2 production (r = 0.48), and heart rate (r = 0.40). No differences were observed in HP and gas exchanges between RG groups. Methane production was null in both groups. Eye temperature measured by thermography was 0.5°C greater in HE-RG than LE-RG calves. Differences in skin temperature between HE and LE calves were not observed at

  2. Breast metastases from rectal carcinoma

    Institute of Scientific and Technical Information of China (English)

    LI Jia; FANG Yu; LI Ang; LI Fei

    2011-01-01

    Metastases to the breast from extramammary neoplasms are very rare, constituting 2.7% of all malignant breast tumours. The most common primary tumor metastatic to the breast is primary breast cancer. Rectal cancer metastasizing to the breast is extremely rare. We report a case of aggressive rectal carcinoma with metastasis to the breast.

  3. Accelerated partial breast irradiation

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    @@ Whole breast radiotherapy afier tumor lumpectomy is based on the premise that that the breast cancer recurrence rate is reduced through the elimination of residual cancer foci in the remaining tissue immediately adjacent to the lumpectomy site and occult multicentric areas of in situ or infiltrating cancer in remote areas of the breast. The relevance of remote foci to ipsilateral breast failure rates after breast conserving treatment is debatable, because 65%~100% of recurrences develop in the same quadrant as the initial tumor. This has led several investigators to question whether radiotherapy must be administered to the entire breast.

  4. Medullary breast carcinoma: anatomo-radiological correlation

    International Nuclear Information System (INIS)

    Matheus, Valeria Soares; Canella, Ellyete de Oliveira; Djahjah, Maria Celia Resende; Koch, Hilton Augusto; Kestelman, Fabiola Procaci

    2008-01-01

    To evaluate radiological findings in patients submitted to surgical treatment for medullary breast cancer at Instituto Nacional de Cancer (INCa), Rio de Janeiro, RJ, Brazil, correlating them with histological results. A retrospective descriptive study was developed with patients submitted to surgery at INCa, in the period from January 1997 to December 2006, for identifying the presence of medullary breast carcinoma and analyzing radiological findings. Among 21,287 patients diagnosed with carcinoma, 76 (0.357%) had typical medullary breast carcinoma. The age range of these patients was 32-81 years (mean = 59.1 years). Mammography demonstrated lesions in 19 of these patients, 17 (89.5%) of them with masses, and 2 with focal asymmetry. Among the patients with masses, 15 (88.1%) presented with high density and 2 (11.9%) with isodensity. Twelve patients presented sonographic findings, 11 (91.6%) of them with hypoechoic masses, and one with an anechoic mass with areas of cystic degeneration. Nodular mass was the predominant radiological finding (89.5%), 88.1% of them corresponding to masses with high density and circumscribed margins. Despite the radiological characteristics of benignity, a solid, fast growing, highly dense mass with circumscribed margins should be further investigated to confirm the diagnosis. (author)

  5. Medullary breast carcinoma: anatomo-radiological correlation

    Energy Technology Data Exchange (ETDEWEB)

    Matheus, Valeria Soares; Canella, Ellyete de Oliveira; Djahjah, Maria Celia Resende; Koch, Hilton Augusto [Instituto Nacional de Cancer (INCa), Rio de Janeiro, RJ (Brazil); Kestelman, Fabiola Procaci [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil); Instituto Nacional de Cancer (INCa), Rio de Janeiro, RJ (Brazil)]. E-mail: msavaleria@yahoo.com

    2008-11-15

    To evaluate radiological findings in patients submitted to surgical treatment for medullary breast cancer at Instituto Nacional de Cancer (INCa), Rio de Janeiro, RJ, Brazil, correlating them with histological results. A retrospective descriptive study was developed with patients submitted to surgery at INCa, in the period from January 1997 to December 2006, for identifying the presence of medullary breast carcinoma and analyzing radiological findings. Among 21,287 patients diagnosed with carcinoma, 76 (0.357%) had typical medullary breast carcinoma. The age range of these patients was 32-81 years (mean = 59.1 years). Mammography demonstrated lesions in 19 of these patients, 17 (89.5%) of them with masses, and 2 with focal asymmetry. Among the patients with masses, 15 (88.1%) presented with high density and 2 (11.9%) with isodensity. Twelve patients presented sonographic findings, 11 (91.6%) of them with hypoechoic masses, and one with an anechoic mass with areas of cystic degeneration. Nodular mass was the predominant radiological finding (89.5%), 88.1% of them corresponding to masses with high density and circumscribed margins. Despite the radiological characteristics of benignity, a solid, fast growing, highly dense mass with circumscribed margins should be further investigated to confirm the diagnosis. (author)

  6. Thermography as an early predictive measurement for evaluating epidural and femoral-sciatic block success in dogs.

    Science.gov (United States)

    Küls, Nina; Blissitt, Karen J; Shaw, Darren J; Schöffmann, Gudrun; Clutton, Richard E

    2017-09-01

    To evaluate skin temperature increase as an early predictive measure for evaluating epidural and femoral-sciatic block success in dogs. Prospective clinical trial. A total of 29 dogs undergoing orthopaedic surgery on one hindlimb. Dogs were anaesthetized and placed into lateral recumbency with the affected limb uppermost and the coat was clipped. Baseline infrared thermographic images (T0) of the affected limb, of the paw pad of the affected leg and of the ipsilateral paw pad were taken. Subsequently, dogs were administered either an epidural (EPI; n=11) or a femoral-sciatic block (FS; n=18) using bupivacaine 1 mg kg -1 . Then, 2 minutes after placement of the block, thermographic images were obtained every 3 minutes for a total of four measurements (T1-T4) and surgery was commenced. Rescue analgesia consisting of fentanyl 1 μg kg -1 was administered if needed. A regional block was considered successful if the dose of fentanyl administered was less than the lower 95% confidence interval of the geometric mean of the total fentanyl used in each group. A ≥ 1 °C increase of skin temperature was considered as the minimum increase required for detection of a successful block. A total of 12 out of 18 blocks in the FS and eight of 11 in the EPI group were considered successful based on fentanyl consumption. Out of these, only four of 12 in the FS and one of eight in the EPI group developed an increase in temperature of ≥ 1 °C. Contrarily, four of six of the nonsuccessful cases in the FS and three of three in the EPI group developed an increase in temperature of ≥ 1 °C. Contrary to reports in humans, thermography did not indicate regional block success prior to surgery in dogs. However further studies under more controlled conditions are needed to determine whether thermography can be used to indicate failure of regional blockade. Copyright © 2017 Association of Veterinary Anaesthetists and American College of Veterinary Anesthesia and Analgesia. Published

  7. Breast cancer screening in Korean woman with dense breast tissue

    International Nuclear Information System (INIS)

    Shin, Hee Jung; Ko, Eun Sook; Yi, Ann

    2015-01-01

    Asian women, including Korean, have a relatively higher incidence of dense breast tissue, compared with western women. Dense breast tissue has a lower sensitivity for the detection of breast cancer and a higher relative risk for breast cancer, compared with fatty breast tissue. Thus, there were limitations in the mammographic screening for women with dense breast tissue, and many studies for the supplemental screening methods. This review included appropriate screening methods for Korean women with dense breasts. We also reviewed the application and limitation of supplemental screening methods, including breast ultrasound, digital breast tomosynthesis, and breast magnetic resonance imaging; and furthermore investigated the guidelines, as well as the study results

  8. Breast cancer screening in Korean woman with dense breast tissue

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Hee Jung [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of); Ko, Eun Sook [Dept. of Radiology, Sungkyunkwan University School of Medicine, Samsung Medical Center, Seoul (Korea, Republic of); Yi, Ann [Dept. of Radiology, Seoul National University College of Medicine, Seoul National University Hospital, Seoul (Korea, Republic of)

    2015-11-15

    Asian women, including Korean, have a relatively higher incidence of dense breast tissue, compared with western women. Dense breast tissue has a lower sensitivity for the detection of breast cancer and a higher relative risk for breast cancer, compared with fatty breast tissue. Thus, there were limitations in the mammographic screening for women with dense breast tissue, and many studies for the supplemental screening methods. This review included appropriate screening methods for Korean women with dense breasts. We also reviewed the application and limitation of supplemental screening methods, including breast ultrasound, digital breast tomosynthesis, and breast magnetic resonance imaging; and furthermore investigated the guidelines, as well as the study results.

  9. Breast Abscess Mimicking Breast Carcinoma in Male.

    Science.gov (United States)

    Gochhait, Debasis; Dehuri, Priyadarshini; Umamahesweran, Sandyya; Kamat, Rohan

    2018-01-01

    Male breast can show almost all pathological entities described in female breast. Inflammatory conditions of the breast in male are not common; however, occasionally, it can be encountered in the form of an abscess. Clinically, gynecomastia always presents as a symmetric unilateral or bilateral lump in the retroareolar region, and any irregular asymmetric lump raises a possibility of malignancy. Radiology should be used as a part of the triple assessment protocol for breast lump along with fine-needle aspiration cytology for definite diagnosis and proper management.

  10. Breast Abscess Mimicking Breast Carcinoma in Male

    Directory of Open Access Journals (Sweden)

    Debasis Gochhait

    2018-01-01

    Full Text Available Male breast can show almost all pathological entities described in female breast. Inflammatory conditions of the breast in male are not common; however, occasionally, it can be encountered in the form of an abscess. Clinically, gynecomastia always presents as a symmetric unilateral or bilateral lump in the retroareolar region, and any irregular asymmetric lump raises a possibility of malignancy. Radiology should be used as a part of the triple assessment protocol for breast lump along with fine-needle aspiration cytology for definite diagnosis and proper management.

  11. BREAST RECONSTRUCTIONS AFTER BREAST CANCER TREATING

    OpenAIRE

    Erik Vrabič

    2018-01-01

    Background. Breasts are an important symbol of physical beauty, feminity, mothering and sexual desire through the entire history of mankind. Lost of the whole or part of the breast is functional and aesthetic disturbance for woman. It is understandable, that the woman, who is concerned over breast loss, is as appropriate as another person´s concern over the loss of a limb or other body part. Before the 1960, breast reconstruction was considered as a dangerous procedure and it was almost prohi...

  12. ED breast cases and other breast emergencies.

    Science.gov (United States)

    Khadem, Nasim; Reddy, Sravanthi; Lee, Sandy; Larsen, Linda; Walker, Daphne

    2016-02-01

    Patients with pathologic processes of the breast commonly present in the Emergency Department (ED). Familiarity with the imaging and management of the most common entities is essential for the radiologist. Additionally, it is important to understand the limitations of ED imaging and management in the acute setting and to recognize when referrals to a specialty breast center are necessary. The goal of this article is to review the clinical presentations, pathophysiology, imaging, and management of emergency breast cases and common breast pathology seen in the ED.

  13. Optical Imaging of the Breast

    International Nuclear Information System (INIS)

    Kim, Min Jung; Kim, Eun Kyung

    2011-01-01

    As the increased prevalence of breast cancer and the advances in breast evaluation awareness have resulted in an increased number of breast examinations and benign breast biopsies, several investigations have been performed to improve the diagnostic accuracy for breast lesions. Optical imaging of the breast that uses nearinfrared light to assess the optical properties of breast tissue is a novel non-invasive imaging technique to characterize breast lesions in clinical practice. This review provides a summary of the current state of optical breast imaging and it describes the basic concepts of optical imaging, the potential clinical applications for breast cancer imaging and its potential incorporation with other imaging modalities

  14. Living Beyond Breast Cancer

    Science.gov (United States)

    ... ACTH CAF CMF FAC TAC TC TCH TH THP Radiation Therapy Whole Breast Radiation Partial Breast Radiation ... Basics Treatments and Your Bone Health Bone Health Tests Improving Bone Health Medicines To Protect Bones Diet, ...

  15. Breast cancer imaging

    International Nuclear Information System (INIS)

    Funke, M.; Villena, C.

    2008-01-01

    Advances in female breast imaging have substantially influenced the diagnosis, therapy, and prognosis of breast cancer in the past few years. Mammography using conventional or digital technique is considered the gold standard for the early detection of breast cancer. Other modalities such as breast ultrasound and contrast-enhanced magnetic resonance imaging of the breast play an important role in diagnostic imaging, staging, and follow-up of breast cancer. Percutaneous needle biopsy is a faster, less invasive, and more cost-effective method than surgical biopsy for verifying the histological diagnosis. New methods such as breast tomosynthesis, contrast-enhanced mammography, and positron emission tomography promise to further improve breast imaging. Further studies are mandatory to adapt these new methods to clinical needs and to evaluate their performance in clinical practice. (orig.) [de

  16. Inflammatory Breast Cancer

    Science.gov (United States)

    ... Common Cancer Types Recurrent Cancer Common Cancer Types Bladder Cancer Breast Cancer Colorectal Cancer Kidney (Renal Cell) Cancer ... white women. Inflammatory breast tumors are frequently hormone receptor negative, which means they cannot be treated with ...

  17. Cosmetic breast surgery - discharge

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000273.htm Cosmetic breast surgery - discharge To use the sharing features on this page, please enable JavaScript. You had cosmetic breast surgery to change the size or shape ...

  18. Breast cancer staging

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000911.htm Breast cancer staging To use the sharing features on this ... Once your health care team knows you have breast cancer , they will do more tests to stage it. ...

  19. The use of high-resolution infrared thermography (HRIT) for the study of ice nucleation and ice propagation in plants.

    Science.gov (United States)

    Wisniewski, Michael; Neuner, Gilbert; Gusta, Lawrence V

    2015-05-08

    Freezing events that occur when plants are actively growing can be a lethal event, particularly if the plant has no freezing tolerance. Such frost events often have devastating effects on agricultural production and can also play an important role in shaping community structure in natural populations of plants, especially in alpine, sub-arctic, and arctic ecosystems. Therefore, a better understanding of the freezing process in plants can play an important role in the development of methods of frost protection and understanding mechanisms of freeze avoidance. Here, we describe a protocol to visualize the freezing process in plants using high-resolution infrared thermography (HRIT). The use of this technology allows one to determine the primary sites of ice formation in plants, how ice propagates, and the presence of ice barriers. Furthermore, it allows one to examine the role of extrinsic and intrinsic nucleators in determining the temperature at which plants freeze and evaluate the ability of various compounds to either affect the freezing process or increase freezing tolerance. The use of HRIT allows one to visualize the many adaptations that have evolved in plants, which directly or indirectly impact the freezing process and ultimately enables plants to survive frost events.

  20. Method for detecting damage in carbon-fibre reinforced plastic-steel structures based on eddy current pulsed thermography

    Science.gov (United States)

    Li, Xuan; Liu, Zhiping; Jiang, Xiaoli; Lodewijks, Gabrol

    2018-01-01

    Eddy current pulsed thermography (ECPT) is well established for non-destructive testing of electrical conductive materials, featuring the advantages of contactless, intuitive detecting and efficient heating. The concept of divergence characterization of the damage rate of carbon fibre-reinforced plastic (CFRP)-steel structures can be extended to ECPT thermal pattern characterization. It was found in this study that the use of ECPT technology on CFRP-steel structures generated a sizeable amount of valuable information for comprehensive material diagnostics. The relationship between divergence and transient thermal patterns can be identified and analysed by deploying mathematical models to analyse the information about fibre texture-like orientations, gaps and undulations in these multi-layered materials. The developed algorithm enabled the removal of information about fibre texture and the extraction of damage features. The model of the CFRP-glue-steel structures with damage was established using COMSOL Multiphysics® software, and quantitative non-destructive damage evaluation from the ECPT image areas was derived. The results of this proposed method illustrate that damaged areas are highly affected by available information about fibre texture. This proposed work can be applied for detection of impact induced damage and quantitative evaluation of CFRP structures.