WorldWideScience

Sample records for thermocouple tumor locations

  1. Heat penetration and thermocouple location in home canning.

    Science.gov (United States)

    Etzel, Mark R; Willmore, Paola; Ingham, Barbara H

    2015-01-01

    We processed applesauce, tomato juice, and cranberries in pint jars in a boiling water canner to test thermal processing theories against home canning of high-acid foods. For each product, thermocouples were placed at various heights in the jar. Values for f h (heating), f cl (cooling), and F 82.2°C (lethality) were determined for each thermocouple location, and did not depend substantially on thermocouple location in accordance with heat transfer theory. There was a cold spot in the jar, but the cold spot during heating became the hot spot during cooling. During heating, the geometric center was the last to heat, and remained coldest the longest, but during coooling, it was also the last to cool, and remained hottest the longest. The net effect was that calculated lethality in home canning was not affected by thermocouple location. Most of the lethality during home canning occurred during air cooling, making cooling of home canned foods of great importance. Calculated lethality was far greater than the required 5-log reduction of spores in tomato juice and vegetative cells in cranberries, suggesting a wide margin of safety for approved home-canning processes for high-acid foods.

  2. Effects of thermocouple installation and location on fuel rod temperature measurements

    International Nuclear Information System (INIS)

    McCormick, R.D.

    1983-01-01

    This paper describes the results of analyses of nuclear fuel rod cladding temperature data obtained during in-reactor experiments under steady state and transient (simulated loss-of-coolant accident) operating conditions. The objective of the analyses was to determine the effect of thermocouple attachment method and location on measured thermal response. The use of external thermocouples increased the time to critical heat flux (CHF), reduced the blowdown peak temperature, and enhanced rod quench. A comparison of laser welded and resistance welded external thermocouple responses showed that the laser welding technique reduced the indicated cladding steady state temperatures and provided shorter time-to-CHF. A comparison of internal welded and embedded thermocouples indicated that the welded technique gave generally unsatisfactory cladding temperature measurements. The embedded thermocouple gave good, consistent results, but was possibly more fragile than the welded thermocouples. Detailed descriptions of the thermocouple designs, attachment methods and locations, and test conditions are provided

  3. Thermocouple

    International Nuclear Information System (INIS)

    Charlesworth, F.D.W.

    1983-01-01

    A thermocouple is provided by a cable of coaxial form with inner and outer conductors of thermocouple forming materials and with the conductors electrically joined together at one end of the cable to form the thermocouple junction. The inner and outer conductors are preferably of chromel and stainless steel respectively. (author)

  4. A thermocouple thermometry system for ultrasound hyperthermia

    International Nuclear Information System (INIS)

    Ozarka, M.; Gharakhani, A.; Magin, R.; Cain, C.

    1984-01-01

    A thermometry system designed to be used in the treatment of cancer by ultrasound hyperthermia is described. The system monitors tumor temperatures using 16 type T (copper-constantan) thermocouples and is controlled by a 12 MHz Intel 8031 microcomputer. An analog circuit board contains the thermocouple amplifiers, an analog multiplexer, scaling circuitry, and an analog to digital converter. A digital board contains the Intel 8031, program memory, data memory, as well as circuitry for control and data communications. Communication with the hyperthermia system control computer is serially by RS-232 with selectable baud rate. Since the thermocouple amplifiers may have slight differences in gain and offset, a calibrated offset is added to a lookup table value to obtain the proper display temperature to within +- 0.1 0 C. The calibration routine, implemented in software, loads a nonvolatile random access memory chip with the proper offset values based on the outputs of each thermocouple channel at known temperatures which bracket a range of interest

  5. Thermocouple pressure bushing in suspension rod

    International Nuclear Information System (INIS)

    Pasek, J.; Ondreicka, K.

    1975-01-01

    The seal is described of jacket thermocouples located in the pressure reducer in the fuel element suspension rod. The thermocouples are sealed in the pressure reducer with a silicon sealing compound. The sealing compound is compressed between the two reducers with a Bellevile spring and a pressure washer secured in position with a spring. The axial pressure of the inner parts of the reducer on the compound is adjustable by means of a thrust screw. The tightness and alignment of the thermocouples in the pressure reducer is achieved by tightening the thrust screw to the stop of the top reducer and the subsequent setting of the sealing compound. (J.B.)

  6. Attaching Thermocouples by Peening or Crimping

    Science.gov (United States)

    Murtland, Kevin; Cox, Robert; Immer, Christopher

    2006-01-01

    at high measurement temperatures. . The simplicity of these techniques makes it possible to attach thermocouples quickly. . These techniques can be used to attach thermocouples at locations where access is somewhat restricted by the surrounding objects.

  7. Characterization of a Method for Inverse Heat Conduction Using Real and Simulated Thermocouple Data

    Science.gov (United States)

    Pizzo, Michelle E.; Glass, David E.

    2017-01-01

    It is often impractical to instrument the external surface of high-speed vehicles due to the aerothermodynamic heating. Temperatures can instead be measured internal to the structure using embedded thermocouples, and direct and inverse methods can then be used to estimate temperature and heat flux on the external surface. Two thermocouples embedded at different depths are required to solve direct and inverse problems, and filtering schemes are used to reduce noise in the measured data. Accuracy in the estimated surface temperature and heat flux is dependent on several factors. Factors include the thermocouple location through the thickness of a material, the sensitivity of the surface solution to the error in the specified location of the embedded thermocouples, and the sensitivity to the error in thermocouple data. The effect of these factors on solution accuracy is studied using the methodology discussed in the work of Pizzo, et. al.1 A numerical study is performed to determine if there is an optimal depth at which to embed one thermocouple through the thickness of a material assuming that a second thermocouple is installed on the back face. Solution accuracy will be discussed for a range of embedded thermocouple depths. Moreover, the sensitivity of the surface solution to (a) the error in the specified location of the embedded thermocouple and to (b) the error in the thermocouple data are quantified using numerical simulation, and the results are discussed.

  8. Composite thermocouples

    International Nuclear Information System (INIS)

    Debeir, R.P.

    1975-01-01

    As a rule, a composite thermocouple is a thermocouple where one or more components (wires, sheath, insulation) differ in kind between the hot junction measurement point and the cold termination with ordinary cables going on to measurement instrumentation. Three categories of such thermocouples are discussed: composite thermocouples having in common the continuity of the thermoelement wires over complete length, and different sheaths and insulation for the high temperature and intermediate temperature parts; those with different thermoelement wires, sheaths, and insulators for the high and intermediate temperature parts; a third category includes the high temperature thermoelements insulated by Al 2 O 3 or BeO and sheathed with a refractory metal, and with the intermediate temperature part made of 2Cr-Al couples, MgO insulated, and stainless steel or inconel sheathed

  9. Studies of Behavior Melting Temperature Characteristics for Multi Thermocouple In-Core Instrument Assembly

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Donghyup; Chae, Myoungeun; Kim, Sungjin; Lee, Kyulim [Woojin inc, Hwasung (Korea, Republic of)

    2015-05-15

    Bottom-up type in-core instruments (ICIs) are used for the pressurized water reactors of OPR-1000, APR- 1400 in order to measure neutron flux and temperature in the reactor. It is a well-known technique and a proven design using years in the nuclear field. ICI consists of one pair of K-type thermocouple, five self-powered neutron detectors (SPNDs) and one back ground detector. K-type thermocouple's purpose is to measure the core exit temperature (CET) in the reactor. The CET is a very important factor for operating nuclear power plants and it is 327 .deg. C when generally operating the reactor in the nuclear power plant(NPP) in case of OPR- 1000. If the CET will exceed 650 .deg. C, Operators in the main control room should be considered to be an accident situation in accordance with a severe accident management guidance(SAMG). The Multi Thermocouple ICI is a new designed ICI assuming severe accident conditions. It consists of four more thermocouples than the existing design, so it has five Ktype thermocouples besides the thermocouple measuring CET is located in the same elevation as the ICI. Each thermocouple is able to be located in the desired location as required. The Multi Thermocouple ICI helps to measure the temperature distribution of the entire reactor. In addition, it will measure certain point of melted core because of the in-vessel debris of nuclear fuel when an accident occurs more seriously. In this paper, to simulate a circumstance such as a nuclear reactor severe accident was examined. In this study, the K-type thermocouples of Multi Thermocouple ICI was confirmed experimentally to be able to measure up to 1370 .deg. C before the thermocouples have been melted. And after the thermocouples were melted by debris, it was able to be monitored that the signal of EMF directed the infinite value of voltage. Therefore through the results of the test, it can be assumed that if any EMF data among the Multi Thermocouple ICI will direct the infinite value

  10. Studies of Behavior Melting Temperature Characteristics for Multi Thermocouple In-Core Instrument Assembly

    International Nuclear Information System (INIS)

    Shin, Donghyup; Chae, Myoungeun; Kim, Sungjin; Lee, Kyulim

    2015-01-01

    Bottom-up type in-core instruments (ICIs) are used for the pressurized water reactors of OPR-1000, APR- 1400 in order to measure neutron flux and temperature in the reactor. It is a well-known technique and a proven design using years in the nuclear field. ICI consists of one pair of K-type thermocouple, five self-powered neutron detectors (SPNDs) and one back ground detector. K-type thermocouple's purpose is to measure the core exit temperature (CET) in the reactor. The CET is a very important factor for operating nuclear power plants and it is 327 .deg. C when generally operating the reactor in the nuclear power plant(NPP) in case of OPR- 1000. If the CET will exceed 650 .deg. C, Operators in the main control room should be considered to be an accident situation in accordance with a severe accident management guidance(SAMG). The Multi Thermocouple ICI is a new designed ICI assuming severe accident conditions. It consists of four more thermocouples than the existing design, so it has five Ktype thermocouples besides the thermocouple measuring CET is located in the same elevation as the ICI. Each thermocouple is able to be located in the desired location as required. The Multi Thermocouple ICI helps to measure the temperature distribution of the entire reactor. In addition, it will measure certain point of melted core because of the in-vessel debris of nuclear fuel when an accident occurs more seriously. In this paper, to simulate a circumstance such as a nuclear reactor severe accident was examined. In this study, the K-type thermocouples of Multi Thermocouple ICI was confirmed experimentally to be able to measure up to 1370 .deg. C before the thermocouples have been melted. And after the thermocouples were melted by debris, it was able to be monitored that the signal of EMF directed the infinite value of voltage. Therefore through the results of the test, it can be assumed that if any EMF data among the Multi Thermocouple ICI will direct the infinite value

  11. Apparatus for spot welding sheathed thermocouples to the inside of small-diameter tubes at precise locations

    International Nuclear Information System (INIS)

    Baucum, W.E.; Dial, R.E.

    1976-01-01

    Equipment and procedures used to spot weld tantalum- or stainless-steel-sheathed thermocouples to the inside diameter of Zircaloy tubing to meet the requirements of the Multirod Burst Test (MRBT) Program at ORNL are described. Spot welding and oxide cleaning tools were fabricated to remove the oxide coating on the Zircaloy tubing at local areas and spot weld four thermocouples separated circumferentially by 90 0 at any axial distribution desired. It was found necessary to apply a nickel coating to stainless-steel-sheathed thermocouples to obtain acceptable welds. The material and shape of the inner electrode and resistance between inner and outer electrodes were found to be critical parameters in obtaining acceptable welds

  12. Thin film ceramic thermocouples

    Science.gov (United States)

    Gregory, Otto (Inventor); Fralick, Gustave (Inventor); Wrbanek, John (Inventor); You, Tao (Inventor)

    2011-01-01

    A thin film ceramic thermocouple (10) having two ceramic thermocouple (12, 14) that are in contact with each other in at least on point to form a junction, and wherein each element was prepared in a different oxygen/nitrogen/argon plasma. Since each element is prepared under different plasma conditions, they have different electrical conductivity and different charge carrier concentration. The thin film thermocouple (10) can be transparent. A versatile ceramic sensor system having an RTD heat flux sensor can be combined with a thermocouple and a strain sensor to yield a multifunctional ceramic sensor array. The transparent ceramic temperature sensor that could ultimately be used for calibration of optical sensors.

  13. Development of a micro-thermal flow sensor with thin-film thermocouples

    Science.gov (United States)

    Kim, Tae Hoon; Kim, Sung Jin

    2006-11-01

    A micro-thermal flow sensor is developed using thin-film thermocouples as temperature sensors. A micro-thermal flow sensor consists of a heater and thin-film thermocouples which are deposited on a quartz wafer using stainless steel masks. Thin-film thermocouples are made of standard K-type thermocouple materials. The mass flow rate is measured by detecting the temperature difference of the thin-film thermocouples located in the upstream and downstream sections relative to a heater. The performance of the micro-thermal flow sensor is experimentally evaluated. In addition, a numerical model is presented and verified by experimental results. The effects of mass flow rate, input power, and position of temperature sensors on the performance of the micro-thermal flow sensor are experimentally investigated. At low values, the mass flow rate varies linearly with the temperature difference. The linearity of the micro-thermal flow sensor is shown to be independent of the input power. Finally, the position of the temperature sensors is shown to affect both the sensitivity and the linearity of the micro-thermal flow sensor.

  14. Temperature monitoring device and thermocouple assembly therefor

    Science.gov (United States)

    Grimm, Noel P.; Bauer, Frank I.; Bengel, Thomas G.; Kothmann, Richard E.; Mavretish, Robert S.; Miller, Phillip E.; Nath, Raymond J.; Salton, Robert B.

    1991-01-01

    A temperature monitoring device for measuring the temperature at a surface of a body, composed of: at least one first thermocouple and a second thermocouple; support members supporting the thermocouples for placing the first thermocouple in contact with the body surface and for maintaining the second thermocouple at a defined spacing from the body surface; and a calculating circuit connected to the thermocouples for receiving individual signals each representative of the temperature reading produced by a respective one of the first and second thermocouples and for producing a corrected temperature signal having a value which represents the temperature of the body surface and is a function of the difference between the temperature reading produced by the first thermocouple and a selected fraction of the temperature reading provided by the second thermocouple.

  15. Travelling gradient thermocouple calibration

    International Nuclear Information System (INIS)

    Broomfield, G.H.

    1975-01-01

    A short discussion of the origins of the thermocouple EMF is used to re-introduce the idea that the Peltier and Thompson effects are indistinguishable from one another. Thermocouples may be viewed as devices which generate an EMF at junctions or as integrators of EMF's developed in thermal gradients. The thermal gradient view is considered the more appropriate, because of its better accord with theory and behaviour, the correct approach to calibration, and investigation of service effects is immediately obvious. Inhomogeneities arise in thermocouples during manufacture and in service. The results of travelling gradient measurements are used to show that such effects are revealed with a resolution which depends on the length of the gradient although they may be masked during simple immersion calibration. Proposed tests on thermocouples irradiated in a nuclear reactor are discussed

  16. Study of thermocouples for control of high temperatures; Etude de thermocouples pour le reperage des hautes temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Villamayor, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires; Faculte des Sciences de l' Universite de Lyon - 69 (France)

    1967-07-01

    Previous works have shown that the tungsten-rhenium alloys thermocouples were a good instrument for control of high temperatures. From its, the author has studied the W/W 26 per cent and W 5 per cent Re/W 26 per cent Re french manufactured thermocouples and intended for control of temperatures in nuclear reactors until 2300 deg. C. In 'out-pile' study he determines the general characteristics of these thermocouples: average calibration curves, thermal shocks influence, response times, and alloys allowing the cold source compensation. The evolution of these thermocouples under thermal neutron flux has been determined by 'in-pile' study. The observations have led the author to propose a new type of thermocouples settled of molybdenum-columbium alloys. (author) [French] Des travaux anterieurs ont montre que les thermocouples des alliages tungstene-rhenium etaient susceptibles de reperer avec precision des hautes temperatures. A partir de la, l'auteur a etudie las thermocouples W/W 26 pour cent Re et W 5 pour cent Re/W 26 pour cent Re de fabrication francaise et destines au controle des temperatures dans les reacteurs nucleaires, jusqu'a 2300 deg. C Dans l'etude 'hors-pile' il a determine les caracteristiques generales de ces thermocouples: courbes d'etalonnage moyen, influence des chocs thermiques, temps de reponse, et alliages assurant la compensation de soudure froide. L'etude 'en-pile' a permis de rendre compte de l'evolution de ces thermocouples sous flux neutroniques. Les phenomenes observes ont conduit l'auteur a proposer un nouveau type de thermocouples constitues d'alliages molybdene-niobium. (auteur)

  17. Thermocouple modeling

    International Nuclear Information System (INIS)

    Fryer, M.O.

    1984-01-01

    The temperature measurements provided by thermocouples (TCs) are important for the operation of pressurized water reactors. During severe inadequate core cooling incidents, extreme temperatures may cause type K thermocouples (TCs) used for core exit temperature monitoring to perform poorly. A model of TC electrical behavior has been developed to determine how TCs react under extreme temperatures. The model predicts the voltage output of the TC and its impedance. A series of experiments were conducted on a length of type K thermocouple to validate the model. Impedance was measured at several temperatures between 22 0 C and 1100 0 C and at frequencies between dc and 10 MHz. The model was able to accurately predict impedance over this wide range of conditions. The average percentage difference between experimental data and the model was less than 6.5%. Experimental accuracy was +-2.5%. There is a sriking difference between impedance versus frequency plots at 300 0 C and at higher temperatures. This may be useful in validating TC data during accident conditions

  18. Fabrication and use of zircaloy/tantalum-sheathed cladding thermocouples and molybdenum/rhenium-sheathed fuel centerline thermocouples

    International Nuclear Information System (INIS)

    Wilkins, S.C.; Sepold, L.K.

    1985-01-01

    The thermocouples described in this report are zircaloy/tantalum-sheathed and molybdenum/rhenium alloy-sheathed instruments intended for fuel rod cladding and fuel centerline temperature measurements, respectively. Both types incorporate beryllium oxide insulation and tungsten/rhenium alloy thermoelements. These thermocouples, operated at temperatures of 2000 0 C and above, were developed for use in the internationally sponsored Severe Fuel Damage test series in the Power Burst Facility. The fabrication steps for both thermocouple types are described in detail. A laser-welding attachment technique for the cladding-type thermocouple is presented, and experience with alternate materials for cladding and fuel therocouples is discussed

  19. [Colorectal cancer the importance of primary tumor location].

    Science.gov (United States)

    Ryska, M; Bauer, J

    2017-01-01

    Retrospective evaluations of the relevance of primary colorectal cancer (CRC) location consistently indicate that right-sided tumors, arising in the cecum, ascending colon, hepatic bend, transverse colon and splenic flexure, are clinically, biologically and genetically different from left-sided tumors - those located in the descending colon, sigmoid colon or rectum. Location in the right-sided colon represents a negative prognostic indicator, particularly for stage III and IV carcinomas. Irrespective of treatment, the rightward location is associated with a significantly increased risk of death when compared to the left side.Key words: colorectal cancer - location - therapy - prognosis.

  20. Adhesive-Bonded Tab Attaches Thermocouples to Titanium

    Science.gov (United States)

    Cook, C. F.

    1982-01-01

    Mechanical strength of titanium-alloy structures that support thermocouples is preserved by first spotwelding thermocouples to titanium tabs and then attaching tabs to titanium with a thermosetting adhesive. In contrast to spot welding, a technique previously used for thermocouples, fatigue strength of the titanium is unaffected by adhesive bonding. Technique is also gentler than soldering or attaching thermocouples with a tap screw.

  1. Knee glomangioma: a rare location for a glomus tumor

    Directory of Open Access Journals (Sweden)

    Ricardo Gonçalves

    2014-12-01

    Full Text Available Glomus tumor is a rare, benign neoplasm rising from the glomus apparatus of the skin. It occurs most frequently on fingers and toes and accounts for 1.6% of all soft tissue tumors. Clinical diagnosis may prove difficult if the tumor occurs on an extra digital location. We report a case of a vascular-type glomus tumor (glomangioma found in an atypical location, namely the lateral aspect of the knee joint.

  2. PWR thermocouple mechanical sealing structure

    International Nuclear Information System (INIS)

    Shen Qiuping; He Youguang

    1991-08-01

    The PWR in-core temperature detection device, which is one of measures to insure reactor safety operation, is to monitor and diagnose reactor thermal power output and in-core power distribution. The temperature detection device system uses thermocouples as measuring elements with stainless steel protecting sleeves. The thermocouple has a limited service time and should be replaced after its service time has reached. A new sealing device for the thermocouples of reactor in-core temperature detection system has been developed to facilitate replacement. The structure is complete tight under high temperature and pressure without any leakage and seepage, and easy to be assembled or disassembled in radioactive environment. The device is designed to make it possible to replace the thermocouple one by one if necessary. This is a new, simple and practical structure

  3. Brain tumor locating in 3D MR volume using symmetry

    Science.gov (United States)

    Dvorak, Pavel; Bartusek, Karel

    2014-03-01

    This work deals with the automatic determination of a brain tumor location in 3D magnetic resonance volumes. The aim of this work is not the precise segmentation of the tumor and its parts but only the detection of its location. This work is the first step in the tumor segmentation process, an important topic in neuro-image processing. The algorithm expects 3D magnetic resonance volumes of brain containing a tumor. The detection is based on locating the area that breaks the left-right symmetry of the brain. This is done by multi-resolution comparing of corresponding regions in left and right hemisphere. The output of the computation is the probabilistic map of the tumor location. The created algorithm was tested on 80 volumes from publicly available BRATS databases containing 3D brain volumes afflicted by a brain tumor. These pathological structures had various sizes and shapes and were located in various parts of the brain. The locating performance of the algorithm was 85% for T1-weighted volumes, 91% for T1-weighted contrast enhanced volumes, 96% for FLAIR and T2-wieghted volumes and 95% for their combinations.

  4. Low Drift Type N Thermocouples for Nuclear Applications

    International Nuclear Information System (INIS)

    Scervini, M.; Rae, C.

    2013-06-01

    Thermocouples are the most commonly used sensors for temperature measurement in nuclear reactors. They are crucial for the control of current nuclear reactors and for the development of GEN IV reactors. In nuclear applications thermocouples are strongly affected by intense neutron fluxes. As a result of the interaction with neutrons, the thermoelements of the thermocouples undergo transmutation, which produces a time dependent change in composition and, as a consequence, a time dependent drift of the thermocouple signal. Thermocouple drift can be very significant for in-pile temperature measurements and may render the temperature sensors unreliable after exposure to nuclear radiation for relatively short times compared to the life required for temperature sensors in nuclear applications. Previous experiences with type K thermocouples in nuclear reactors have shown that they are affected by neutron irradiation only to a limited extent. Similarly type N thermocouples are expected to be only slightly affected by neutron fluxes. Currently the use of Nickel based thermocouples is limited to temperatures lower than 1000 deg. C due to drift related to phenomena other than nuclear irradiation. In this work, undertaken as part of the European project METROFISSION, the drift of type N thermocouples has been investigated in the temperature range 600-1300 deg. C. The approach of this study is based on the attempt to separate the contributions of each thermo-element to drift. In order to identify the dominant thermo-element for drift, the contributions of both positive (NP) and negative (NN) thermo-elements to the total drift of 3.2 mm diameter MIMS thermocouples have been measured in each drift test using a pure Pt thermo-element as a reference. Conventional Inconel-600 sheathed type N thermocouples have been compared with type N thermocouples sheathed in a new alloy. At temperatures higher than 1000 deg. C conventional Inconel600 sheathed type N thermocouples can experience a

  5. Noncontacting Measurement With a Thermocouple

    Science.gov (United States)

    Weatherill, W. T.; Schoreder, C. J.; Freitag, H. J.

    1986-01-01

    Tentlike covering brings thermocouple to within few degrees of surface temperature. Technique originally developed for measuring surface temperature of quartz fabric under radiant heating requires no direct contact with heated surface. Technique particularly useful when measuring surface temperatures of materials damaged if thermocouple or other temperature sensor attached.

  6. LOFT small break test thermocouple installation

    International Nuclear Information System (INIS)

    Fors, R.M.

    1980-01-01

    The subject thermocouple design has been analyzed for maximum expected hydraulic loading and found to be adequate. The natural frequency of the thermocouple was found to be between the vortex shedding frequencies for the gas and liquid phase so that a tendency for resonance will exist. However, since the thermocouple support will have a restricted displacement, stresses found are below the endurance limit and, thus, are acceptable in respect to fatigue life as well as primary stress due to pressure loading

  7. Microprocessor-controlled Nd:YAG laser for hyperthermia induction in the RIF-1 tumor.

    Science.gov (United States)

    Waldow, S M; Russell, G E; Wallner, P E

    1992-01-01

    Near-infrared radiation from a Nd:YAG laser at 1,064 nm was used interstitially or superficially to induce hyperthermia in RIF-1 tumors in C3H male mice. A single 600-microns quartz fiber with a 0.5-cm cylindrical diffusor or a weakly diverging microlens at its distal end was used to deliver laser energy to tumors in the hind leg (mean volume = 100 mm3). Two thermocouples were inserted into each tumor. One thermocouple controlled a microprocessor-driven hyperthermia program (maximum output of 3.5 Watts) to maintain the desired temperature. Tumors were exposed to various temperature-time combinations (42-45 degrees C/30 min). Our initial results indicated that excellent temperature control to within 0.2 degrees C of the desired temperature at the feedback thermocouple was achievable during both superficial and interstitial heat treatments. Temperatures at the second thermocouple, however, were found to be lower by as much as 2.3 degrees C (using the cylindrical diffusor) or higher by up to 4.6 degrees C (using the microlens) when compared to the feedback thermocouple temperature. Several correlations were seen between total dose, tumor growth delay, percent skin necrosis, and temperature at the second thermocouple after several superficial and interstitial treatments. Statistically significant improvements in tumor growth delay (at 42 and 45 degrees C) and increased percent skin necrosis at all temperatures were observed after superficial versus interstitial treatment.

  8. Transmutation of Thermocouples in Thermal and Fast Nuclear Reactors

    International Nuclear Information System (INIS)

    Scervini, M.; Rae, C.; Lindley, B.

    2013-06-01

    Thermocouples are the most commonly used sensors for temperature measurement in nuclear reactors. Their role is fundamental for the control of current nuclear reactors and for the development of the nuclear technology needed for the implementation of GEN IV nuclear reactors. When used for in-core measurements thermocouples are strongly affected not only by high temperatures, but also by intense neutron fluxes. As a result of the interaction with neutrons, the thermoelements of the thermocouples undergo transmutation, which produces a time dependent change in composition in the thermoelements and, as a consequence, a time dependent drift in the thermocouple signal. Thermocouple drift can be very significant for in-pile temperature measurements and may render the temperature sensors unreliable after exposure to nuclear radiation for relatively short times compared to the life required for temperature sensors in nuclear applications. In this work, undertaken as part of the European project METROFISSION, the change in composition occurring in irradiated thermocouples has been calculated using the software ORIGEN 2.2. Several thermocouples have been considered, including Nickel based thermocouples (type K and type N), Tungsten based thermocouples (W-5%Re vs W-26%Re and W- 3%Re vs W-25%Re), Platinum based thermocouples (type S and Platinum vs Palladium) and Molybdenum vs Niobium thermocouples. The transmutation induced by both thermal flux and fast flux has been calculated. Thermocouples undergo more pronounced transmutation in thermal fluxes rather than in fast fluxes, as the neutron cross section of an element is higher for thermal energies. Nickel based thermocouples have a minimal change in composition, while Platinum based and Tungsten based thermocouples experience a very significant transmutation. The use of coatings deposited on the sheath of a thermocouple has been considered as a mean to reduce the neutron flux the thermoelements inside the thermocouple sheath

  9. Spatial filtring and thermocouple spatial filter

    International Nuclear Information System (INIS)

    Han Bing; Tong Yunxian

    1989-12-01

    The design and study on thermocouple spatial filter have been conducted for the flow measurement of integrated reactor coolant. The fundamental principle of spatial filtring, mathematical descriptions and analyses of thermocouple spatial filter are given

  10. Sputtered type s thermocouples on quartz glass substrates

    International Nuclear Information System (INIS)

    Sopko, B.; Vlk, J.; Chren, D.; Sopko, V.; Dammer, J.; Mengler, J.; Hynek, V.

    2011-01-01

    The work deals with the development of thin film thermocouples and their practical use. The principle of measuring planar thin film thermocouples is the same as for conventional thermocouples and is based on the thermoelectric effect, which named after its discoverer, Seebeck. Seebeck effect is direct conversion of temperature differences to electric voltage. In different applications it is necessary to use temperature sensors with high spatial resolution (with the placement of several measured points on the segment of length 1 mm) and short response time. For this application are currently used planar thermocouples with important advantage in production price and reproducible production. The innovative potential of thin-film thermocouples are to be found mainly in: 1 st use of technology in thin layers, unlike the already mature technologies applied in the production of conventional thermocouple probes are capable of further improvement with the usage of new substrate materials, modified methods for creating electrical contacts to the new thermocouple configuration and adhesive and protective layers, 2 nd in saving precious and rare metals, 3 rd decreasing the thickness of the layers and reducing the overall size of thermo probe. Measuring the temperature of molten steel, leading to a general loss of strength and the subsequent destruction of the probe. Here exhibited the highest resistance of quartz plates used in thin film substrates thermocouples. (authors)

  11. Embedded cladding surface thermocouples on Zircaloy-sheathed heater rods

    International Nuclear Information System (INIS)

    Wilkins, S.C.

    1977-06-01

    Titanium-sheathed Type K thermocouples embedded in the cladding wall of zircaloy-sheathed heater rods are described. These thermocouples constitute part of a program intended to characterize the uncertainty of measurements made by surface-mounted cladding thermocouples on nuclear fuel rods. Fabrication and installation detail, and laboratory testing of sample thermocouple installations are included

  12. Base metal thermocouples drift rate dependence from thermoelement diameter

    Science.gov (United States)

    Pavlasek, P.; Duris, S.; Palencar, R.

    2015-02-01

    Temperature measurements are one of the key factors in many industrial applications that directly affect the quality, effectiveness and safety of manufacturing processes. In many industrial applications these temperature measurements are realized by thermocouples. Accuracy of thermocouples directly affects the quality of the final product of manufacturing and their durability determines the safety margins required. One of the significant effects that affect the precision of the thermocouples is short and long term stability of their voltage output. This stability issue occurs in every type of thermocouples and is caused by multiple factors. In general these factors affect the Seebeck coefficient which is a material constant, which determines the level of generated voltage when exposed to a temperature gradient. Changes of this constant result in the change of the thermocouples voltage output thus indicated temperature which can result in production quality issues, safety and health hazards. These alternations can be caused by physical and chemical changes within the thermocouple lead material. Modification of this material constant can be of temporary nature or permanent. This paper concentrates on the permanent, or irreversible changes of the Seebeck coefficient that occur in commonly used swaged MIMS Type N thermocouples. These permanent changes can be seen as systematic change of the EMF of the thermocouple when it is exposed to a high temperature over a period of time. This change of EMF by time is commonly known as the drift of the thermocouple. This work deals with the time instability of thermocouples EMF at temperatures above 1200 °C. Instability of the output voltage was taken into relation with the lead diameter of the tested thermocouples. This paper concentrates in detail on the change of voltage output of thermocouples of different diameters which were tested at high temperatures for the overall period of more than 210 hours. The gather data from this

  13. Base metal thermocouples drift rate dependence from thermoelement diameter

    International Nuclear Information System (INIS)

    Pavlasek, P; Duris, S; Palencar, R

    2015-01-01

    Temperature measurements are one of the key factors in many industrial applications that directly affect the quality, effectiveness and safety of manufacturing processes. In many industrial applications these temperature measurements are realized by thermocouples. Accuracy of thermocouples directly affects the quality of the final product of manufacturing and their durability determines the safety margins required. One of the significant effects that affect the precision of the thermocouples is short and long term stability of their voltage output. This stability issue occurs in every type of thermocouples and is caused by multiple factors. In general these factors affect the Seebeck coefficient which is a material constant, which determines the level of generated voltage when exposed to a temperature gradient. Changes of this constant result in the change of the thermocouples voltage output thus indicated temperature which can result in production quality issues, safety and health hazards. These alternations can be caused by physical and chemical changes within the thermocouple lead material. Modification of this material constant can be of temporary nature or permanent. This paper concentrates on the permanent, or irreversible changes of the Seebeck coefficient that occur in commonly used swaged MIMS Type N thermocouples. These permanent changes can be seen as systematic change of the EMF of the thermocouple when it is exposed to a high temperature over a period of time. This change of EMF by time is commonly known as the drift of the thermocouple. This work deals with the time instability of thermocouples EMF at temperatures above 1200 °C. Instability of the output voltage was taken into relation with the lead diameter of the tested thermocouples. This paper concentrates in detail on the change of voltage output of thermocouples of different diameters which were tested at high temperatures for the overall period of more than 210 hours. The gather data from this

  14. Study of thermocouples for control of high temperatures

    International Nuclear Information System (INIS)

    Villamayor, M.

    1966-12-01

    Previous works have shown that the tungsten-rhenium alloys thermocouples were a good instrument for control of high temperatures. From its, the author has studied the W/W 26 per cent and W 5 per cent Re/W 26 per cent Re french manufactured thermocouples and intended for control of temperatures in nuclear reactors until 2300 deg. C. In 'out-pile' study he determines the general characteristics of these thermocouples: average calibration curves, thermal shocks influence, response times, and alloys allowing the cold source compensation. The evolution of these thermocouples under thermal neutron flux has been determined by 'in-pile' study. The observations have led the author to propose a new type of thermocouples settled of molybdenum-columbium alloys. (author) [fr

  15. Thermocouple evaluation model and evaluation of chromel--alumel thermocouples for High-Temperature Gas-Cooled Reactor applications

    International Nuclear Information System (INIS)

    Washburn, B.W.

    1977-03-01

    Factors affecting the performance and reliability of thermocouples for temperature measurements in High-Temperature Gas-Cooled Reactors are investigated. A model of an inhomogeneous thermocouple, associated experimental technique, and a method of predicting measurement errors are described. Error drifts for Type K materials are predicted and compared with published stability measurements. 60 references

  16. Zircaloy sheathed thermocouples for PWR fuel rod temperature measurements

    International Nuclear Information System (INIS)

    Anderson, J.V.; Wesley, R.D.; Wilkins, S.C.

    1979-01-01

    Small diameter zircaloy sheathed thermocouples have been developed by EG and G Idaho, Inc., at the Idaho National Engineering Laboratory. Surface mounted thermocouples were developed to measure the temperature of zircaloy clad fuel rods used in the Thermal Fuels Behavior Program (TFBP), and embedded thermocouples were developed for use by the Loss-of-Fluid Test (LOFT) Program for support tests using zircaloy clad electrically heated nuclear fuel rod simulators. The first objective of this developmental effort was to produce zircaloy sheathed thermocouples to replace titanium sheathed thermocouples and thereby eliminate the long-term corrosion of the titanium-to-zircaloy attachment weld. The second objective was to reduce the sheath diameter to obtain faster thermal response and minimize cladding temperature disturbance due to thermocouple attachment

  17. Operating problems of the thermocouples in VVER

    International Nuclear Information System (INIS)

    Timonin, A.S.

    1997-01-01

    In WWER reactors, the coolant temperature at the outlet of the majority of fuel assemblies is measured with chromel-alumel cable thermocouples. The components of systematic errors in temperature measurements are discussed. Errors due to calibration drift can be avoided by periodical calibrations performed during the heating and hot test runs after reactor refueling. Errors due to radiation heating and response time can be estimated and thus eliminated. Errors due to flow stratification of the coolant can also be eliminated by an estimation of correction factors. The effects of the aging of the thermocouples are also discussed. The removal of thermocouples from their coverings for replacement presents some difficulties, which thus determine the service life of the thermocouples. (A.K.)

  18. Thermocouple Rakes for Measuring Boundary Layer Flows Extremely Close to Surface

    Science.gov (United States)

    Hwang, Danny P.; Fralick, Gustave C.; Martin, Lisa C.; Blaha, Charles A.

    2001-01-01

    Of vital interest to aerodynamic researchers is precise knowledge of the flow velocity profile next to the surface. This information is needed for turbulence model development and the calculation of viscous shear force. Though many instruments can determine the flow velocity profile near the surface, none of them can make measurements closer than approximately 0.01 in. from the surface. The thermocouple boundary-layer rake can measure much closer to the surface than conventional instruments can, such as a total pressure boundary layer rake, hot wire, or hot film. By embedding the sensors (thermocouples) in the region where the velocity is equivalent to the velocity ahead of a constant thickness strut, the boundary-layer flow profile can be obtained. The present device fabricated at the NASA Glenn Research Center microsystem clean room has a heater made of platinum and thermocouples made of platinum and gold. Equal numbers of thermocouples are placed both upstream and downstream of the heater, so that the voltage generated by each pair at the same distance from the surface is indicative of the difference in temperature between the upstream and downstream thermocouple locations. This voltage differential is a function of the flow velocity, and like the conventional total pressure rake, it can provide the velocity profile. In order to measure flow extremely close to the surface, the strut is made of fused quartz with extremely low heat conductivity. A large size thermocouple boundary layer rake is shown in the following photo. The latest medium size sensors already provide smooth velocity profiles well into the boundary layer, as close as 0.0025 in. from the surface. This is about 4 times closer to the surface than the previously used total pressure rakes. This device also has the advantage of providing the flow profile of separated flow and also it is possible to measure simultaneous turbulence levels within the boundary layer.

  19. Self-adapted thermocouple-diagnostic complex

    International Nuclear Information System (INIS)

    Alekseev, S.V.; Grankovskij, K.Eh.; Olejnikov, P.P.; Prijmak, S.V.; Shikalov, V.F.

    2003-01-01

    A self-adapted thermocouple-diagnostic complex (STDC) for obtaining the reliable data on the coolant temperature in the reactors of NPP is described. The STDC in based on the thermal pulse monitoring of a thermocouple in the measuring channel of a reactor. Measurement method and STDC composition are substantiated. It is shown that introduction of the developed STDC ensures realization of precise and reliable temperature monitoring in the reactors of all types [ru

  20. A comprehensive survey of thermoelectric homogeneity of commonly used thermocouple types

    Science.gov (United States)

    Machin, Jonathan; Tucker, Declan; Pearce, Jonathan V.

    2018-06-01

    Thermocouples are widely used as temperature sensors in industry. The electromotive force generated by a thermocouple is produced in a temperature gradient and not at the thermocouple tip. This means that the thermoelectric inhomogeneity represents one of the most important contributions to the overall measurement uncertainty associated with thermocouples. To characterise this effect, and to provide some general recommendations concerning the magnitude of this contribution to use when formulating uncertainty analyses, a comprehensive literature survey has been performed. Significant information was found for Types K, N, R, S, B, Pt/Pd, Au/Pt and various other Pt/Rh thermocouples. In the case of Type K and N thermocouples, the survey has been augmented by a substantial amount of data based on calibrations of mineral-insulated, metal-sheathed thermocouple cable reels from thermocouple manufacturers. Some general conclusions are drawn and outline recommendations given concerning typical values for the uncertainty arising from thermoelectric inhomogeneity for the most widely used thermocouple types in the as-new state. It is stressed that these recommendations should only be heeded when individual homogeneity measurements are not possible. It is also stressed that the homogeneity can deteriorate rapidly during use, particularly for base metal thermocouples.

  1. Location of tumor affects local and distant immune cell type and number.

    Science.gov (United States)

    Hensel, Jonathan A; Khattar, Vinayak; Ashton, Reading; Lee, Carnellia; Siegal, Gene P; Ponnazhagan, Selvarangan

    2017-03-01

    Tumors comprise heterogeneous populations of cells, including immune infiltrates that polarize during growth and metastasis. Our preclinical studies on breast cancer (BCa) identified functional differences in myeloid-derived suppressor cells based on tumor microenvironment (TME), prompting variations in host immune response to tumor growth, and dissemination based on tissue type. In order to understand if such variations existed among other immune cells, and if such alteration occurs in response to tumor growth at the primary site or due to bone dissemination, we characterized immune cells, examining localized growth and in the tibia. In addition, immune cells from the spleen were examined from animals of both tumor locations by flow cytometry. The study demonstrates that location of tumor, and not simply the tumor itself, has a definitive role in regulating immune effectors. Among all immune cells characterized, macrophages were decreased and myeloid dendritic cell were increased in both tumor locations. This difference was more evident in subcutaneous tumors. Additionally, spleens from mice with subcutaneous tumors contained greater increases in both macrophages and myeloid dendritic cells than in mice with bone tumors. Furthermore, in subcutaneous tumors there was an increase in CD4 + and CD8 + T-cell numbers, which was also observed in their spleens. These data indicate that alterations in tumor-reactive immune cells are more pronounced at the primary site, and exert a similar change at the major secondary lymphoid organ than in the bone TME. These findings could provide translational insight into designing therapeutic strategies that account for location of metastatic foci.

  2. Predicting survival for well-differentiated liposarcoma: the importance of tumor location.

    Science.gov (United States)

    Smith, Caitlin A; Martinez, Steve R; Tseng, Warren H; Tamurian, Robert M; Bold, Richard J; Borys, Dariusz; Canter, Robert J

    2012-06-01

    Although well-differentiated liposarcoma (WD Lipo) is a low grade neoplasm with a negligible risk of metastatic disease, it can be locally aggressive. We hypothesized that survival for WD Lipo varies significantly based on tumor location. We identified 1266 patients with WD Lipo in the Surveillance, Epidemiology, and End Results database from 1988-2004. After excluding patients diagnosed by autopsy only, those lacking histologic confirmation, those lacking data on tumor location, and those with metastatic disease or unknown staging information, we arrived at a final study cohort of 1130 patients. Clinical, pathologic, and treatment variables were analyzed for their association with overall survival (OS) and disease-specific survival (DSS) using Kaplan-Meier analysis and Cox proportional hazards multivariate models. Mean age was 61 y (± 14.6), 72.2% were white, and 60.4% were male. Eighty-one percent of patients were treated with surgical therapy alone, 4.6% were treated with radiotherapy (RT) alone, and 12.9% were treated with both surgery and RT. Extremity location was most common (41.6%), followed by trunk (29%), retroperitoneal/intra-abdominal (RIA, 21.6%), thorax (4.2%), and head/neck (3.6%). With a median follow-up of 45 mo, median OS was 115 mo (95% confidence interval [CI] 92-138 mo) for RIA tumors compared to not reached for other tumor locations (P = 0.002). On multivariate analysis, increasing age and RIA location both predicted worse OS and DSS while tumor size, race, sex, receipt of RT, and Surveillance, Epidemiology, and End Results (SEER) stage did not. Tumor size became a significant predictor of worse DSS, but not OS, only when site, SEER stage, and extent of resection were removed from the multivariate model. Non-RIA locations, including extremity, experienced statistically similar OS, but 5-y DSS for trunk location was intermediate [92.3%, (95% CI 88.5%-96.1%) compared with 98.0% (95% CI, 96.2%-99.8%) for extremity and 86.6 (95% CI 81

  3. Characteristics of metal sheathed thermocouples in thermowell

    International Nuclear Information System (INIS)

    Okuda, Takehiro; Nakase, Tsuyoshi; Tanabe, Yutaka; Yamada, Kunitaka; Yoshizaki, Akio; Roko, Kiyokazu

    1987-01-01

    Static and dynamic characteristics of thermowell type thermocouples which are planned to be used for the High-Temperature engineering Test Reactor (HTTR) have been investigated. A mock-up test section was installed in Kawasaki's Helium Test Loop (KH-200). Thermal characteristics tests were carried out under the 600 ∼ 1000 deg C temperature conditions. The test section was equipped with four types sheathed thermocouples; the well type, the non well type, and ones with and without the thermal radiation shielding plate. The measured temperature by the well type thermocouples with the shielding plate was only about 1.3 deg C higher than the one without the shielding plate at gas temperature 990 deg C. The measured time constant of the well type thermocouples was about 7 seconds in the condition of the heat transfer coefficient 1600 Kcal/m 2 h deg C on the well surface, and coincided with the calculated one by ''TRUMP'' code. (author)

  4. Estimation of radiation losses from sheathed thermocouples

    International Nuclear Information System (INIS)

    Roberts, I.L.; Coney, J.E.R.; Gibbs, B.M.

    2011-01-01

    Thermocouples are often used for temperature measurements in heat exchangers. However if the radiation losses from a thermocouple in a high temperature gas flow to colder surroundings are ignored significant errors can occur. Even at moderate temperature differences, these can be significant. Prediction of radiation losses from theory can be problematic, especially in situations where there are large variations in the measured temperatures as the emissivity and radiative heat transfer coefficient of the thermocouple are not constant. The following approach combines experimental results with established empirical relationships to estimate losses due to radiation in an annular heat exchanger at temperatures up to 950 o C. - Highlights: → Sheathed thermocouples are often used to measure temperatures in heat exchangers. → Errors are introduced if radiation losses are ignored. → Radiation losses are environment specific and may be significant. → Experimental and theoretical methods are used to estimate losses. → Hot side maximum temperature 950 o C.

  5. Metallic and Ceramic Thin Film Thermocouples for Gas Turbine Engines

    Directory of Open Access Journals (Sweden)

    Otto J. Gregory

    2013-11-01

    Full Text Available Temperatures of hot section components in today’s gas turbine engines reach as high as 1,500 °C, making in situ monitoring of the severe temperature gradients within the engine rather difficult. Therefore, there is a need to develop instrumentation (i.e., thermocouples and strain gauges for these turbine engines that can survive these harsh environments. Refractory metal and ceramic thin film thermocouples are well suited for this task since they have excellent chemical and electrical stability at high temperatures in oxidizing atmospheres, they are compatible with thermal barrier coatings commonly employed in today’s engines, they have greater sensitivity than conventional wire thermocouples, and they are non-invasive to combustion aerodynamics in the engine. Thin film thermocouples based on platinum:palladium and indium oxynitride:indium tin oxynitride as well as their oxide counterparts have been developed for this purpose and have proven to be more stable than conventional type-S and type-K thin film thermocouples. The metallic and ceramic thin film thermocouples described within this paper exhibited remarkable stability and drift rates similar to bulk (wire thermocouples.

  6. Tumor location and IDH1 mutation may predict intraoperative seizures during awake craniotomy.

    Science.gov (United States)

    Gonen, Tal; Grossman, Rachel; Sitt, Razi; Nossek, Erez; Yanaki, Raneen; Cagnano, Emanuela; Korn, Akiva; Hayat, Daniel; Ram, Zvi

    2014-11-01

    Intraoperative seizures during awake craniotomy may interfere with patients' ability to cooperate throughout the procedure, and it may affect their outcome. The authors have assessed the occurrence of intraoperative seizures during awake craniotomy in regard to tumor location and the isocitrate dehydrogenase 1 (IDH1) status of the tumor. Data were collected in 137 consecutive patients who underwent awake craniotomy for removal of a brain tumor. The authors performed a retrospective analysis of the incidence of seizures based on the tumor location and its IDH1 mutation status, and then compared the groups for clinical variables and surgical outcome parameters. Tumor location was strongly associated with the occurrence of intraoperative seizures. Eleven patients (73%) with tumor located in the supplementary motor area (SMA) experienced intraoperative seizures, compared with 17 (13.9%) with tumors in the other three non-SMA brain regions (p awake craniotomy compared with patients who have a tumor in non-SMA frontal areas and other brain regions. The IDH1 mutation was more common in SMA region tumors compared with other brain regions, and may be an additional risk factor for the occurrence of intraoperative seizures.

  7. Technological improvements to high temperature thermocouples for nuclear reactor applications

    International Nuclear Information System (INIS)

    Schley, R.; Leveque, J.P.

    1980-07-01

    The specific operating conditions of thermocouples in nuclear reactors have provided an incentive for further advances in high temperature thermocouple applications and performance. This work covers the manufacture and improvement of existing alloys, the technology of clad thermocouples, calibration drift during heat treatment, resistance to thermal shock and the compatibility of insulating materials with thermo-electric alloys. The results lead to specifying improved operating conditions for thermocouples in nuclear reactor media (pressurized water, sodium, uranium oxide) [fr

  8. Thin film platinum–palladium thermocouples for gas turbine engine applications

    Energy Technology Data Exchange (ETDEWEB)

    Tougas, Ian M.; Gregory, Otto J., E-mail: gregory@egr.uri.edu

    2013-07-31

    Thin film platinum:palladium thermocouples were fabricated on alumina and mullite surfaces using radio frequency sputtering and characterized after high temperature exposure to oxidizing environments. The thermoelectric output, hysteresis, and drift of these sensors were measured at temperatures up to 1100 °C. Auger electron spectroscopy was used to follow the extent of oxidation in each thermocouple leg and interdiffusion at the metallurgical junction. Minimal oxidation of the platinum and palladium thermoelements was observed after high temperature exposure, but considerable dewetting and faceting of the films were observed in scanning electron microscopy. An Arrhenius temperature dependence on the drift rate was observed and later attributed to microstructural changes during thermal cycling. The thin film thermocouples, however, did exhibit excellent stability at 1000 °C with drift rates comparable to commercial type-K wire thermocouples. Based on these results, platinum:palladium thin film thermocouples have considerable potential for use in the hot sections of gas turbine engines. - Highlights: • Stable thin film platinum:palladium thermocouples for gas turbine engines • Little oxidation but significant microstructural changes from thermal cycling • Minimal hysteresis during repeated thermal cycling • Drift comparable to commercial wire thermocouples.

  9. A method to eliminate the effect of radiation on thermocouple performance

    International Nuclear Information System (INIS)

    Ali, Fawaz; Lu Lixuan

    2007-01-01

    In-core temperature measurements are pivotal in maintaining nuclear reactors in a safe state of operation. Thermocouples serve as the liaison in ensuring this safe state. The realization of the thermocouple's full potential is hindered by the fact that thermocouples cannot be situated in areas with high radiation fields. Radiation has the potential of generating voltages in the thermocouple wires, hence producing an error in the temperature transmitter output. In this paper, a mathematical model is developed to quantify the effect that radiation from the Canada Deuterium Uranium (CANDU) Nuclear Power Plants (NPPs) has on the thermocouple temperature reading. Subsequently, a method to offset the effect of radiation on the thermocouple is proposed. Simulation is performed to verify the effectiveness of the proposed system

  10. The disposition of can thermocouples in a nuclear reactor

    International Nuclear Information System (INIS)

    Wilkie, D.

    1978-01-01

    A philosophy is presented for deciding the distribution of can thermocouples within channels and of instrumented channels throughout the core of a reactor with cluster-type fuel elements when only a few thermocouples can be located in any one channel. The arrangement is made according to a 'factorial' design in which all fuel element positions of interest are covered in a group of channels. Two types of factorial design can be applied: the unconfounded design by which the thermocouples in each channel are chosen at random from the possible positions available, with the results that the temperatures have attached to them an uncertainty determined by the differences among channels; and the confounded design by which the positions are chosen so as to give temperatures whose uncertainty is determined only by the random variations within channels. It is also necessary to estimate standard deviations in order to predict the number of cans likely to reach a given temperature. The standard deviation can be expected to vary with channel position, and since there will also be systematic variations in temperature with channel position it is necessary to arrange channels into groups having similar mean fluxes and flux distributions. Each group is instrumented according to the pattern of a confounded design. The information that such an arrangement provides is an estimate of the systematic temperature variations within channels, estimates of within-channel variation of can temperature, of between-channel variation of can temperature, and of the variation of these quantities among groups of channels grouped according to similarity of mean flux and flux profile. (author)

  11. The development of a fast response thermocouple for use in liquid metals

    International Nuclear Information System (INIS)

    Morss, A.G.; Vincent, B.

    1987-03-01

    Work carried out at Berkeley Nuclear Laboratories to develop a fast-response thermocouple for use in liquid metals is described. This thermocouple because of its unique construction, has a junction mass approaching zero and hence its frequency response should be very high. Some of the problems of manufacture are discussed, in particular the high quality of seal required to avoid ingress of liquid metal. A comparison of results obtained with the fast-response thermocouple and with conventional stainless-steel-sheathed thermocouples is made. The improved response of the new thermocouple is clearly visible, hence confirming that measurements made with sheathed thermocouples suffer attenuation. It is concluded that results obtained with the fast-response thermocouple are close to the real magnitude of temperature fluctuations present in turbulent flow. It is also demonstrated that, with suitable corrections, results obtained with sheathed thermocouples can be used to estimate the real signals present in the flow. (author)

  12. Summary of Thermocouple Performance During Advanced Gas Reactor Fuel Irradiation Experiments in the Advanced Test Reactor and Out-of-Pile Thermocouple Testing in Support of Such Experiments

    Energy Technology Data Exchange (ETDEWEB)

    A. J. Palmer; DC Haggard; J. W. Herter; M. Scervini; W. D. Swank; D. L. Knudson; R. S. Cherry

    2011-07-01

    High temperature gas reactor experiments create unique challenges for thermocouple based temperature measurements. As a result of the interaction with neutrons, the thermoelements of the thermocouples undergo transmutation, which produces a time dependent change in composition and, as a consequence, a time dependent drift of the thermocouple signal. This drift is particularly severe for high temperature platinum-rhodium thermocouples (Types S, R, and B); and tungsten-rhenium thermocouples (Types C and W). For lower temperature applications, previous experiences with type K thermocouples in nuclear reactors have shown that they are affected by neutron irradiation only to a limited extent. Similarly type N thermocouples are expected to be only slightly affected by neutron fluxes. Currently the use of these Nickel based thermocouples is limited when the temperature exceeds 1000°C due to drift related to phenomena other than nuclear irradiation. High rates of open-circuit failure are also typical. Over the past ten years, three long-term Advanced Gas Reactor (AGR) experiments have been conducted with measured temperatures ranging from 700oC – 1200oC. A variety of standard Type N and specialty thermocouple designs have been used in these experiments with mixed results. A brief summary of thermocouple performance in these experiments is provided. Most recently, out of pile testing has been conducted on a variety of Type N thermocouple designs at the following (nominal) temperatures and durations: 1150oC and 1200oC for 2000 hours at each temperature, followed by 200 hours at 1250oC, and 200 hours at 1300oC. The standard Type N design utilizes high purity crushed MgO insulation and an Inconel 600 sheath. Several variations on the standard Type N design were tested, including Haynes 214 alloy sheath, spinel (MgAl2O4) insulation instead of MgO, a customized sheath developed at the University of Cambridge, and finally a loose assembly thermocouple with hard fired alumina

  13. Summary of thermocouple performance during advanced gas reactor fuel irradiation experiments in the advanced test reactor and out-of-pile thermocouple testing in support of such experiments

    Energy Technology Data Exchange (ETDEWEB)

    Palmer, A. J.; Haggard, DC; Herter, J. W.; Swank, W. D.; Knudson, D. L.; Cherry, R. S. [Idaho National Laboratory, P.O. Box 1625, MS 4112, Idaho Falls, ID, (United States); Scervini, M. [University of Cambridge, Department of Material Science and Metallurgy, 27 Charles Babbage Road, CB3 0FS, Cambridge, (United Kingdom)

    2015-07-01

    High temperature gas reactor experiments create unique challenges for thermocouple-based temperature measurements. As a result of the interaction with neutrons, the thermoelements of the thermocouples undergo transmutation, which produces a time-dependent change in composition and, as a consequence, a time-dependent drift of the thermocouple signal. This drift is particularly severe for high temperature platinum-rhodium thermocouples (Types S, R, and B) and tungsten-rhenium thermocouples (Type C). For lower temperature applications, previous experiences with Type K thermocouples in nuclear reactors have shown that they are affected by neutron irradiation only to a limited extent. Similarly, Type N thermocouples are expected to be only slightly affected by neutron fluence. Currently, the use of these nickel-based thermocouples is limited when the temperature exceeds 1000 deg. C due to drift related to phenomena other than nuclear irradiation. High rates of open-circuit failure are also typical. Over the past 10 years, three long-term Advanced Gas Reactor experiments have been conducted with measured temperatures ranging from 700 deg. C - 1200 deg. C. A variety of standard Type N and specialty thermocouple designs have been used in these experiments with mixed results. A brief summary of thermocouple performance in these experiments is provided. Most recently, out-of-pile testing has been conducted on a variety of Type N thermocouple designs at the following (nominal) temperatures and durations: 1150 deg. C and 1200 deg. C for 2,000 hours at each temperature, followed by 200 hours at 1250 deg. C and 200 hours at 1300 deg. C. The standard Type N design utilizes high purity, crushed MgO insulation and an Inconel 600 sheath. Several variations on the standard Type N design were tested, including a Haynes 214 alloy sheath, spinel (MgAl{sub 2}O{sub 4}) insulation instead of MgO, a customized sheath developed at the University of Cambridge, and finally a loose assembly

  14. Thermocouple correlation transit time flowmeter tests at WCL

    International Nuclear Information System (INIS)

    Lassahn, G.D.

    1976-11-01

    Scoping tests indicate the feasibility for using transit time flowmeters with thermocouple sensors in steam-water steady state flow. Conclusive results were not obtained. More conclusive results are expected from tests to be conducted in the semiscale facility with a redesigned transit time thermocouple sensor

  15. Analysis of limb function after various reconstruction methods according to tumor location following resection of pediatric malignant bone tumors

    Directory of Open Access Journals (Sweden)

    Tokuhashi Yasuaki

    2010-05-01

    Full Text Available Abstract Background In the reconstruction of the affected limb in pediatric malignant bone tumors, since the loss of joint function affects limb-length discrepancy expected in the future, reconstruction methods that not only maximally preserve the joint function but also maintain good limb function are necessary. We analysis limb function of reconstruction methods by tumor location following resection of pediatric malignant bone tumors. Patients and methods We classified the tumors according to their location into 3 types by preoperative MRI, and evaluated reconstruction methods after wide resection, paying attention to whether the joint function could be preserved. The mean age of the patients was 10.6 years, Osteosarcoma was observed in 26 patients, Ewing's sarcoma in 3, and PNET(primitive neuroectodermal tumor and chondrosarcoma (grade 1 in 1 each. Results Type I were those located in the diaphysis, and reconstruction was performed using a vascularized fibular graft(vascularized fibular graft. Type 2 were those located in contact with the epiphyseal line or within 1 cm from this line, and VFG was performed in 1, and distraction osteogenesis in 1. Type III were those extending from the diaphysis to the epiphysis beyond the epiphyseal line, and a Growing Kotz was mainly used in 10 patients. The mean functional assessment score was the highest for Type I (96%: n = 4 according to the type and for VFG (99% according to the reconstruction method. Conclusion The final functional results were the most satisfactory for Types I and II according to tumor location. Biological reconstruction such as VFG and distraction osteogenesis without a prosthesis are so high score in the MSTS rating system. Therefore, considering the function of the affected limb, a limb reconstruction method allowing the maximal preservation of joint function should be selected after careful evaluation of the effects of chemotherapy and the location of the tumor.

  16. Zircaloy-sheathed element rods fitted with thermo-couples; Barre combustible a thermocouple gainee de zircaloy

    Energy Technology Data Exchange (ETDEWEB)

    Bernardy de Sigoyer, B; Jacques, F; Thome, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-07-01

    In order to carry out thermal conductivity measurements on UO{sub 2} in conditions similar to those under which fuel rods are used, it was necessary to measure the temperature at the interior of a fuel element sheathed in zircaloy. The temperatures are taken with Thermocoax type thermocouples, that is to say fitted with a very thin sheath of stainless steel or Inconel. It is known also that fusion welding of zircaloy onto stainless steel is impossible and that high temperature welded joints are very difficult because of their aggressiveness. The technique used consists in brazing the thermocouples to relatively large stainless steel parts and then joining these plugs by electron bombardment welding to diffused stainless steel-zircaloy couplings. The properties of these diffused couplings and of the brazed joints were studied; the various stages in the fabrication of the containers are also described. (authors) [French] Pour des mesures de conductivite thermique de l'UO{sub 2} dans des conditions voisines du fonctionnement des barres combustibles, il s'agissait de mesurer la temperature a l'interieur d'un element combustible gaine de zircaloy. Les prises de temperature sont faites par thermocouples du type Thermocoax, c'est-a-dire pourvu d'une gaine tres mince en inox ou inconel. Par ailleurs on sait que le soudage par fusion du zircaloy sur l'inox est impossible et que les brasures a haute temperature sont difficiles car tres agressives. La technique utilisee consiste a braser les thermocouples sur des pieces en inox relativement massives et de rapporter par soudage au bombardement electronique ces bouchons sur des raccords diffuses zircaloy-inox. Les proprietes de ces raccords diffuses et celles de joints brases ont ete etudiees; on expose egalement les diverses etapes de fabrication des containers. (auteurs)

  17. Relative humidity measurements with thermocouple psychrometer and capacitance sensors

    International Nuclear Information System (INIS)

    Mao, Naihsien.

    1991-01-01

    The relative humidity is one of the important hydrological parameters affecting waste package performance. Water potential of a system is defined as the amount of work required to reversibly and isothermally move an infinitesimal quantity of water from a pool of pure water to that system at the same elevation. The thermocouple psychrometer, which acts as a wet-dry bulb instrument based on the Peltier effect, is used to measure water potential. The thermocouple psychrometer works only for relative humidity greater than 94 percent. Other sensors must be used for drier conditions. Hence, the author also uses a Vaisala Humicap, which measures the capacitance change due to relative humidity change. The operation range of the Humicap (Model HMP 135Y) is from 0 to 100 percent relative humidity and up to 160C (320F) in temperature. A psychrometer has three thermocouple junctions. Two copper-constantan junctions serve as reference temperature junctions and the constantan-chromel junction is the sensing junction. Current is passed through the thermocouple causing cooling of the sensing junction by the Peltier effect. When the temperature of the junction is below the dew point, water will condense upon the junction from the air. The Peltier current is discontinued and the thermocouple output is recorded as the temperature of the thermocouple returns to ambient. The temperature changes rapidly toward the ambient temperature until it reaches the wet bulb depression temperature. At this point, evaporation of the water from the junction produces a cooling effect upon the junction that offsets the heat absorbed from the ambient surroundings. This continues until the water is depleted and the thermocouple temperature returns to the ambient temperature (Briscoe, 1984). The datalogger starts to take data roughly at the wet bulb depression temperature

  18. Thermocouple design for measuring temperatures of small insects

    Science.gov (United States)

    A.A. Hanson; R.C. Venette

    2013-01-01

    Contact thermocouples often are used to measure surface body temperature changes of insects during cold exposure. However, small temperature changes of minute insects can be difficult to detect, particularly during the measurement of supercooling points. We developed two thermocouple designs, which use 0.51 mm diameter or 0.127 mm diameter copper-constantan wires, to...

  19. Error analysis of thermocouple measurements in the Radiant Heat Facility

    International Nuclear Information System (INIS)

    Nakos, J.T.; Strait, B.G.

    1980-12-01

    The measurement most frequently made in the Radiant Heat Facility is temperature, and the transducer which is used almost exclusively is the thermocouple. Other methods, such as resistance thermometers and thermistors, are used but very rarely. Since a majority of the information gathered at Radiant Heat is from thermocouples, a reasonable measure of the quality of the measurements made at the facility is the accuracy of the thermocouple temperature data

  20. Realization of Copper Melting Point for Thermocouple Calibrations

    Directory of Open Access Journals (Sweden)

    Y. A. ABDELAZIZ

    2011-08-01

    Full Text Available Although the temperature stability and uncertainty of the freezing plateau is better than that of the melting plateau in most of the thermometry fixed points, but realization of melting plateaus are easier than that of freezing plateaus for metal fixed points. It will be convenient if the melting points can be used instead of the freezing points in calibration of standard noble metal thermocouples because of easier realization and longer plateau duration of melting plateaus. In this work a comparison between the melting and freezing points of copper (Cu was carried out using standard noble metal thermocouples. Platinum - platinum 10 % rhodium (type S, platinum – 30 % rhodium / platinum 6 % rhodium (type B and platinum - palladium (Pt/Pd thermocouples are used in this study. Uncertainty budget analysis of the melting points and freezing points is presented. The experimental results show that it is possible to replace the freezing point with the melting point of copper cell in the calibration of standard noble metal thermocouples in secondary-level laboratories if the optimal methods of realization of melting points are used.

  1. Measuring skin temperature before, during and after exercise: a comparison of thermocouples and infrared thermography

    International Nuclear Information System (INIS)

    Fernandes, Alex de Andrade; Amorim, Paulo Roberto dos Santos; De Moura, Anselmo Gomes; Moreira, Danilo Gomes; Costa, Carlos Magno Amaral; Marins, João Carlos Bouzas; Brito, Ciro José; Sillero-Quintana, Manuel

    2014-01-01

    Measuring skin temperature (T SK ) provides important information about the complex thermal control system and could be interesting when carrying out studies about thermoregulation. The most common method to record T SK  involves thermocouples at specific locations; however, the use of infrared thermal imaging (IRT) has increased. The two methods use different physical processes to measure T SK , and each has advantages and disadvantages. Therefore, the objective of this study was to compare the mean skin temperature (MT SK ) measurements using thermocouples and IRT in three different situations: pre-exercise, exercise and post-exercise. Analysis of the residual scores in Bland–Altman plots showed poor agreement between the MT SK  obtained using thermocouples and those using IRT. The averaged error was −0.75 °C during pre-exercise, 1.22 °C during exercise and −1.16 °C during post-exercise, and the reliability between the methods was low in the pre- (ICC = 0.75 [0.12 to 0.93]), during (ICC = 0.49 [−0.80 to 0.85]) and post-exercise (ICC = 0.35 [−1.22 to 0.81] conditions. Thus, there is poor correlation between the values of MT SK  measured by thermocouples and IRT pre-exercise, exercise and post-exercise, and low reliability between the two forms of measurement. (paper)

  2. Outcome of four-dimensional stereotactic radiotherapy for centrally located lung tumors

    International Nuclear Information System (INIS)

    Nuyttens, Joost J.; Voort van Zyp, Noelle C. van der; Praag, John; Aluwini, Shafak; Klaveren, Rob J. van; Verhoef, Cornelis; Pattynama, Peter M.; Hoogeman, Mischa S.

    2012-01-01

    Purpose: To assess local control, overall survival, and toxicity of four-dimensional, risk-adapted stereotactic body radiotherapy (SBRT) delivered while tracking respiratory motion in patients with primary and metastatic lung cancer located in the central chest. Methods: Fifty-eight central lesions of 56 patients (39 with primary, 17 with metastatic tumors) were treated. Fifteen tumors located near the esophagus were treated with 6 fractions of 8 Gy. Other tumors were treated according to the following dose escalation scheme: 5 fractions of 9 Gy (n = 6), then 5 fractions of 10 Gy (n = 15), and finally 5 fractions of 12 Gy (n = 22). Results: Dose constraints for critical structures were generally achieved; in 21 patients the coverage of the PTV was reduced below 95% to protect adjacent organs at risk. At a median follow-up of 23 months, the actuarial 2-years local tumor control was 85% for tumors treated with a BED >100 Gy compared to 60% for tumors treated with a BED ⩽100 Gy. No grade 4 or 5 toxicity was observed. Acute grade 1–2 esophagitis was observed in 11% of patients. Conclusion: SBRT of central lung lesions can be safely delivered, with promising early tumor control in patients many of whom have severe comorbid conditions.

  3. Prognosis by tumor location for pediatric spinal cord Ependymomas

    OpenAIRE

    Oh, MC; Sayegh, ET; Safaee, M; Sun, MHZ; Kaur, G; Kim, JM; Aranda, D; Molinaro, AM; Gupta, N; Parsa, AT

    2013-01-01

    Object. Ependymoma is a common CNS tumor in children, with spinal cord ependymomas making up 13.1% of all ependymomas in this age group. The clinical features that affect prognosis in pediatric spinal cord ependymomas are not well understood. A comprehensive literature review was performed to determine whether a tumor location along the spinal cord is prognostically significant in children undergoing surgery for spinal cord ependymomas. Methods. A PubMed search was performed to identify all p...

  4. Long duration performance of high temperature irradiation resistant thermocouples

    International Nuclear Information System (INIS)

    Rempe, J.; Knudson, D.; Condie, K.; Cole, J.; Wilkins, S.C.

    2007-01-01

    Many advanced nuclear reactor designs require new fuel, cladding, and structural materials. Data are needed to characterize the performance of these new materials in high temperature, radiation conditions. However, traditional methods for measuring temperature in-pile degrade at temperatures above 1100 C degrees. To address this instrumentation need, the Idaho National Laboratory (INL) developed and evaluated the performance of a high temperature irradiation-resistant thermocouple that contains alloys of molybdenum and niobium. To verify the performance of INL's recommended thermocouple design, a series of high temperature (from 1200 to 1800 C) long duration (up to six months) tests has been initiated. This paper summarizes results from the tests that have been completed. Data are presented from 4000 hour tests conducted at 1200 and 1400 C that demonstrate the stability of this thermocouple (less than 2% drift). In addition, post test metallographic examinations are discussed which confirm the compatibility of thermocouple materials throughout these long duration, high temperature tests. (authors)

  5. Impact of removed tumor volume and location on patient outcome in glioblastoma.

    Science.gov (United States)

    Awad, Al-Wala; Karsy, Michael; Sanai, Nader; Spetzler, Robert; Zhang, Yue; Xu, Yizhe; Mahan, Mark A

    2017-10-01

    Glioblastoma is an aggressive primary brain tumor with devastatingly poor prognosis. Multiple studies have shown the benefit of wider extent of resection (EOR) on patient overall survival (OS) and worsened survival with larger preoperative tumor volumes. However, the concomitant impact of postoperative tumor volume and eloquent location on OS has yet to be fully evaluated. We performed a retrospective chart review of adult patients treated for glioblastoma from January 2006 through December 2011. Adherence to standardized postoperative chemoradiation protocols was used as an inclusion criterion. Detailed volumetric and location analysis was performed on immediate preoperative and immediate postoperative magnetic resonance imaging. Cox proportional hazard modeling approach was employed to explore the modifying effects of EOR and eloquent location after adjusting for various confounders and associated characteristics, such as preoperative tumor volume and demographics. Of the 471 screened patients, 141 were excluded because they did not meet all inclusion criteria. The mean (±SD) age of the remaining 330 patients (60.6% male) was 58.9 ± 12.9 years; the mean preoperative and postoperative Karnofsky performance scores (KPSs) were 76.2 ± 10.3 and 80.0 ± 16.6, respectively. Preoperative tumor volume averaged 33.2 ± 29.0 ml, postoperative residual was 4.0 ± 8.1 ml, and average EOR was 88.6 ± 17.6%. The observed average follow-up was 17.6 ± 15.7 months, and mean OS was 16.7 ± 14.4 months. Survival analysis showed significantly shorter survival for patients with lesions in periventricular (16.8 ± 1.7 vs. 21.5 ± 1.4 mo, p = 0.03), deep nuclei/basal ganglia (11.6 ± 1.7 vs. 20.6 ± 1.2, p = 0.002), and multifocal (12.0 ± 1.4 vs. 21.3 ± 1.3 months, p = 0.0001) locations, but no significant influence on survival was seen for eloquent cortex sites (p = 0.14, range 0.07-0.9 for all individual

  6. Temperature measurements by thermocouples

    International Nuclear Information System (INIS)

    Liermann, J.

    1975-01-01

    The measurement of a temperature (whatever the type of transducer used) raises three problems: the choice of transducer; where it should be placed; how it should be fixed and protected. These are the three main points examined, after a brief description of the most commonly used thermocouples [fr

  7. A Study of the Behavior Characteristics for K-type Thermocouple

    International Nuclear Information System (INIS)

    Ye, Songhae; Kim, Yongsik; Lee, Sooill; Kim, Sungjin; Lyou, Jooon

    2014-01-01

    K-type thermocouple is widely used in nuclear power plants (NPP) and they provide reliable service. Generally, the thermocouple assembly is the finished product and usually only nondestructive tests are performed on the assembly, whereas destructive tests are confined to selected bulk cable specimens. This K-type thermocouple has been used representatively in the In-Core Instrument Assembly (ICI) in the nuclear power plants. The ICI consists of five rhodium emitter detectors that provide information on the thermal power for the core and one K-type thermocouple made with two cables (Chromel-Alumel) that provides the temperature of core exit (CET). Generally, the quantity of the ICI is absolutely different according to the number of fuel assemblies in the NPP. In the case of SKN 3 and 4, they were designed to the 61 ICI to provide information on the core cooling to the inadequate core cooling monitoring system (ICCMS). This measured temperature could be also used to check the entry condition of severe accidents. The technology of the TFDR is a generic skill to detect the fault position of the cable. In-core Instruments (ICIs) were used to detect the Core Exit Temperature (CET) in a reactor. This measured temperature was also used to check the entry condition of severe accidents. However, if a serious accident occurs, the upper portion of the core is damaged. This instrument has not been available. This paper illustrates the estimation possibility for the status of molten core through the high-temperature characteristics test of k-type thermocouple. It turns out that it is possible to measure the k-type thermocouple up to 1350 .deg. C degrees before melting during insertion into the melting furnace. Additionally, in order to measure a high temperature of 2000 .deg. C or more, the replacement possibility of k-type thermocouple was evaluated. However the tungsten-rhenium thermocouple is impossible to use in the detection of temperature at the in-core because of the

  8. The effect of tumor location and respiratory function on tumor movement estimated by real-time tracking radiotherapy (RTRT) system

    International Nuclear Information System (INIS)

    Onimaru, Rikiya; Shirato, Hiroki; Fujino, Masaharu; Suzuki, Keishiro; Yamazaki, Kouichi; Nishimura, Masaharu; Dosaka-Akita, Hirotoshi; Miyasaka, Kazuo

    2005-01-01

    Purpose: The effects of tumor location and pulmonary function on the motion of fiducial markers near lung tumors were evaluated to deduce simple guidelines for determining the internal margin in radiotherapy without fiducial markers. Methods and Materials: Pooled data collected by a real-time tumor-tracking radiotherapy system on 42 markers in 39 patients were analyzed. The pulmonary functions of all patients were assessed before radiotherapy. Using chest X-ray film, the position of the marker was expressed relative to the geometry of the unilateral lung. Posterior location meant the area of the posterior half of the lung in a lateral chest X-ray film, and caudal location meant the caudal half of the chest X-ray film; these categories were determined by measuring the distance between the marker and anatomic landmarks, including the apex, costophrenic angle, midline of spinal canal, lateral, anterior, and posterior boundary of the lung. Results: Before the radiotherapy, 18 patients had obstructive respiratory dysfunction (ratio of forced expiratory volume in 1 s to forced vital capacity [FEV 1.0 /FVC] 1.0 /FVC and %VC were 97.0% and 66.5%, respectively. Median tumor movements in the x (left-right), y (anteroposterior), and z (craniocaudal) directions were 1.1 mm, 2.3 mm, and 5.4 mm, respectively. There was no significant correlation between respiratory function and magnitude of marker movement in any direction. Median marker movement in the z direction was 2.6 mm for the cranial location and 11.8 mm for the caudal location, respectively (p < 0.001). Median movement in the z direction was 11.8 mm for posterior location and 3.4 mm for anterior location, respectively (p < 0.01). Conclusions: Simple measurement of the relative location on plain chest X-ray film was related, but respiratory function test was not related, to the craniocaudal amplitude of the motion of the fiducial marker near lung tumors

  9. SU-G-JeP1-06: Correlation of Lung Tumor Motion with Tumor Location Using Electromagnetic Tracking

    Energy Technology Data Exchange (ETDEWEB)

    Muccigrosso, D; Maughan, N; Parikh, P [Washington University School of Medicine, Saint Louis, MO (United States); Schultejans, H; Bera, R [Lindbergh High School, St. Louis, MO (United States)

    2016-06-15

    Purpose: It is well known that lung tumors move with respiration. However, most measurements of lung tumor motion have studied long treatment times with intermittent imaging; those populations may not necessarily represent conventional LINAC patients. We summarized the correlation between tumor motion and location in a multi-institutional trial with electromagnetic tracking, and identified the patient cohort that would most benefit from respiratory gating. Methods: Continuous electromagnetic transponder data (Varian Medical, Seattle, WA) of lung tumor motion was collected from 14 patients (214 total fractions) across 3 institutions during external beam radiation therapy in a prospective clinical trial (NCT01396551). External intervention from the clinician, such as couch shifts, instructed breath-holds, and acquisition pauses, were manually removed from the 10 Hz tracking data according to recorded notes. The average three-dimensional displacement from the breathing cycle’s end-expiratory to end-inhalation phases (peak-to-peak distance) of the transponders’ isocenter was calculated for each patient’s treatment. A weighted average of each isocenter was used to assess the effects of location on motion. A total of 14 patients were included in this analysis, grouped by their transponders’ location in the lung: upper, medial, and lower. Results: 8 patients had transponders in the upper lung, and 3 patients each in the medial lobe and lower lung. The weighted average ± standard deviation of all peak-to-peak distances for each group was: 1.04 ± 0.39 cm in the lower lung, 0.56 ± 0.14 cm in the medial lung, and 0.30 ± 0.06 cm in the upper lung. Conclusion: Tumors in the lower lung are most susceptible to excessive motion and daily variation, and would benefit most from continuous motion tracking and gating. Those in the medial lobe might be at moderate risk. The upper lobes have limited motion. These results can guide different motion management strategies

  10. Stability Studies of a New Design Au/Pt Thermocouple Without a Strain Relieving Coil

    Science.gov (United States)

    Jahan, Ferdouse; Ballico, Mark

    2007-12-01

    The performance of a simple, new design Au/Pt thermocouple developed by NMIA is assessed. This thermocouple is proposed as a more accurate replacement, over the temperature range from 0 to 1,000°C, for the commonly used Type R and S industrial transfer standards, in a robust form familiar to industrial calibration laboratories. Due to the significantly different thermal expansions of the Au and Pt thermoelements, reported designs of the Au/Pt thermocouple incorporate a strain-relieving coil or bridge at the thermocouple junction. As the strain relieving coil is mechanically delicate, these thermocouples are usually mounted in a protective quartz tube assembly, like a standard platinum resistance thermometer (SPRT). Although providing uncertainties at the mK level, they are more delicate than the commonly used Type R and S thermocouples. A new and simple design of the Au/Pt thermocouple was developed in which the differential thermal expansion between Au and Pt is accommodated in the thermocouple leads, facilitated by a special head design. The resulting thermocouple has the appearance and robustness of the traditional Type R and S thermocouples, while retaining stability better than 10 mK up to 961°C. Three thermocouples of this design were calibrated at fixed points and by comparison to SPRTs in a stirred salt bath. In order to assess possible impurity migration, strain effects, and mechanical robustness, sequences of heat treatment up to a total of 500 h together with over 50 thermal cycles from 900°C to ambient were performed. The effect of these treatments on the calibration was assessed, demonstrating the sensors to be robust and stable to better than 10 mK. The effects on the measured inhomogeneity of the thermocouple were assessed using the NMIA thermocouple scanning bath.

  11. Contact Thermocouple Methodology and Evaluation for Temperature Measurement in the Laboratory

    Science.gov (United States)

    Brewer, Ethan J.; Pawlik, Ralph J.; Krause, David L.

    2013-01-01

    Laboratory testing of advanced aerospace components very often requires highly accurate temperature measurement and control devices, as well as methods to precisely analyze and predict the performance of such components. Analysis of test articles depends on accurate measurements of temperature across the specimen. Where possible, this task is accomplished using many thermocouples welded directly to the test specimen, which can produce results with great precision. However, it is known that thermocouple spot welds can initiate deleterious cracks in some materials, prohibiting the use of welded thermocouples. Such is the case for the nickel-based superalloy MarM-247, which is used in the high temperature, high pressure heater heads for the Advanced Stirling Converter component of the Advanced Stirling Radioisotope Generator space power system. To overcome this limitation, a method was developed that uses small diameter contact thermocouples to measure the temperature of heater head test articles with the same level of accuracy as welded thermocouples. This paper includes a brief introduction and a background describing the circumstances that compelled the development of the contact thermocouple measurement method. Next, the paper describes studies performed on contact thermocouple readings to determine the accuracy of results. It continues on to describe in detail the developed measurement method and the evaluation of results produced. A further study that evaluates the performance of different measurement output devices is also described. Finally, a brief conclusion and summary of results is provided.

  12. Does circumferential tumor location affect the circumferential resection margin status in mid and low rectal cancer?

    Directory of Open Access Journals (Sweden)

    Byung Mo Kang

    2018-05-01

    Full Text Available Summary: Background/Objective: The purpose of this study was to assess the impact of circumferential tumor location on circumferential resection margin (CRM status and the depth of tumor invasion in mid and low rectal cancer. Methods: We retrospectively analyzed whole-mount slides of 58 patients who underwent total mesorectal excision for mid and low rectal cancer. The rate of tumor-positive CRM was compared according to the circumferential tumor location. In 31 patients, morphometric analyses of whole-mount specimens were performed to measure the depth of tumor invasion according to circumferential tumor location. Results: Among 58 patients, 50% of tumors were anterior tumor and 50% were nonanterior. A tumor-positive CRM was more observed frequently in anterior tumors than in nonanterior tumors (41.1% vs. 10.3%, p = 0.007. In a multivariate analysis, anterior tumor was the only independent risk factor for a positive CRM (odds ratio 4.725, 95% confidence interval 1.102–20.261, p = 0.037. In a morphometric analysis of 31 patients, the depth of tumor invasion from the muscularis mucosa was greater (11.9 mm vs. 6.6 mm, p = 0.028 in those with anterior tumors. Conclusion: Anterior tumors are associated with a higher risk of tumor-positive CRM and tend to exhibit deeper invasion in mid and low rectal cancer. Keywords: circumferential resection margin, depth of invasion, rectal cancer, tumor location

  13. Thermocouples for conditions of aggressive environments

    International Nuclear Information System (INIS)

    Blanc, J.Y.

    1988-01-01

    Two new kinds of thermocouples have been chosen for temperature measurements in the in-pile safety program for light water reactors performed in France. They must give fuel centerline or roc cladding temperatures and withstand steam oxidation between 1000 0 C and 1800 0 C or higher, under severe fuel damage conditions. We describe briefly both types, then we emphasize on improvements under way concerning the tungsten-rhenium legs, the hafnia insulation and the sheaths materials. Oxidation resistance is achieved mainly by silicides layers, but other possibilities are considered, such as iridium coatings. Some details of insulators manufacturing or sensor assembly are given, as well as other high temperature applications for these thermocouples

  14. Number and location of mouse mammary tumor virus proviral DNA in mouse DNA of normal tissue and of mammary tumors.

    Science.gov (United States)

    Groner, B; Hynes, N E

    1980-01-01

    The Southern DNA filter transfer technique was used to characterize the genomic location of the mouse mammary tumor proviral DNA in different inbred strains of mice. Two of the strains (C3H and CBA) arose from a cross of a Bagg albino (BALB/c) mouse and a DBA mouse. The mouse mammary tumor virus-containing restriction enzyme DNA fragments of these strains had similar patterns, suggesting that the proviruses of these mice are in similar genomic locations. Conversely, the pattern arising from the DNA of the GR mouse, a strain genetically unrelated to the others, appeared different, suggesting that its mouse mammary tumor proviruses are located in different genomic sites. The structure of another gene, that coding for beta-globin, was also compared. The mice strains which we studied can be categorized into two classes, expressing either one or two beta-globin proteins. The macroenvironment of the beta-globin gene appeared similar among the mice strains belonging to one genetic class. Female mice of the C3H strain exogenously transmit mouse mammary tumor virus via the milk, and their offspring have a high incidence of mammary tumor occurrence. DNA isolated from individual mammary tumors taken from C3H mice or from BALB/c mice foster nursed on C3H mothers was analyzed by the DNA filter transfer technique. Additional mouse mammary tumor virus-containing fragments were found in the DNA isolated from each mammary tumor. These proviral sequences were integrated into different genomic sites in each tumor. Images PMID:6245257

  15. The use of thermocouples which transmute during service in nuclear reactors

    International Nuclear Information System (INIS)

    Martin, R.E.

    1980-06-01

    Some current nuclear fuel experiments at CRNL require the use of thermocouples to measure temperatures of up to 2200 0 C under reactor operating conditions. A literature search has shown that transient electrical effects and transmutation of the thermocouple alloys can cause temperature measurement errors of up to +-1% and +-30%, respectively. However, the error due to transient electrical effects can be corrected by making temperature measurements immediately following reactor shutdown. Furthermore it has been shown that transmutation effects can be corrected for by calibrating the high temperature tungsten-rhenium thermocouples against a chromel-alumel thermocouple in a cooler part of the experiment. The use of these techniques is expected to reduce temperature measurement errors to +-2% in the best case. (auth)

  16. Verification of skin dose according to the location of tumor in Tomotherapy

    International Nuclear Information System (INIS)

    Yoon, Bo Reum; Park, Su Yeon; Park, Byoung Suk; KIm, Jong Sik; Song, Ki Won

    2014-01-01

    To verify the skin dose in Tomotherapy-based radiation treatment according to the change in tumor locations, skin dose was measured by using Gafchromic EBT3 film and compared with the planned doses to find out the gap between them. In this study, to measure the skin dose, I'm RT Phantom(IBA Dosimetry, Germany) was utilized. After obtaining the 2.5 mm CT images, tumor locations and skin dose measuring points were set by using Pinnacle(ver 9.2, Philips Medical System, USA). The tumor location was decided to be 5 mm and 10 mm away from surface of the phantom and center. Considering the attenuation of a Tomo-couch, we ensured a symmetric placement between the ceiling and floor directions of the phantom. The measuring point of skin doses was set to have 3 mm and 5 mm thickness from the surface. Measurement was done 3 times. By employing TomoHD(TomoHD treatment system, Tomotherapy Inc., Madison, Wisconsin, USA), we devised Tomotherapy plans, measured 3 times by inserting Gafchromic EBT3 film into the phantom and compared the measurement with the skin dose treatment plans. The skin doses in the upper part of the phantom, when the tumor was located in the center, were found to be 7.53 cGy and 7.25 cGy in 5 mm and 3 mm respectively. If placed 5 mm away from the skin in the ceiling direction, doses were 18.06 cGy and 16.89 cGy; if 10 mm away, 20.37 cGy and 18.27 cGy, respectively. The skin doses in the lower part of the phantom, when the tumor was located in the center, recorded 8.82 cGy and 8.29 cGy in 5 mm and 3 mm, each; if located 5mm away from the lower part skin, 21.69 cGy and 19.78 cGy were respectively recorded; and if 10 mm away, 20.48 cGy and 19.57 cGy were recorded. If the tumor was placed in the center, skin doses were found to increase by 3.2-17.1% whereas if the tumor is 5 mm away from the ceiling part, the figure decreased to 2.8-9.0%. To the Tomo-couch direction, skin doses showed an average increase of 11% or over, compared to the planned treatment

  17. Blind system identification of two-thermocouple sensor based on cross-relation method

    Science.gov (United States)

    Li, Yanfeng; Zhang, Zhijie; Hao, Xiaojian

    2018-03-01

    In dynamic temperature measurement, the dynamic characteristics of the sensor affect the accuracy of the measurement results. Thermocouples are widely used for temperature measurement in harsh conditions due to their low cost, robustness, and reliability, but because of the presence of the thermal inertia, there is a dynamic error in the dynamic temperature measurement. In order to eliminate the dynamic error, two-thermocouple sensor was used to measure dynamic gas temperature in constant velocity flow environments in this paper. Blind system identification of two-thermocouple sensor based on a cross-relation method was carried out. Particle swarm optimization algorithm was used to estimate time constants of two thermocouples and compared with the grid based search method. The method was validated on the experimental equipment built by using high temperature furnace, and the input dynamic temperature was reconstructed by using the output data of the thermocouple with small time constant.

  18. Mineral insulated thermocouples - installation in steam generating plant

    International Nuclear Information System (INIS)

    Bridges, W.J.; Brown, J.F.

    1980-01-01

    The main areas of interest considered are Central Station Fossil Fuel fired boilers of around 500 MW capacity, AGR Boilers, and Industrial and Research Development projects. While the requirement for temperature measurement in each of these areas may vary the techniques adopted to overcome installation and protection problems created by thermal, chemical and mechanical hazards remain basically the same. The reasons for temperature measurement are described together with methods of attachment development and procedures for protection of the thermocouple along its route length until its exit from the hazardous environment. These relative accuracies of the different attachments are discussed along with factors influencing the life of the thermocouple. In many instances thermocouple installation is either a once only opportunity and/or an expensive exercise. It is therefore essential to develop and apply an effective quality control system during the installation phase. An effective system is described. Finally, a brief outline of possible future trends is given. (author)

  19. Cladding temperature measurement by thermocouples at preirradiated LWR fuel rod samples

    International Nuclear Information System (INIS)

    Leiling, W.

    1981-12-01

    This report describes the technique to measure cladding temperatures of test fuel rod samples, applied during the in-pile tests on fuel rod failure in the steam loop of the FR2 reactor. NiCr/Ni thermocouples with stainless steel and Inconel sheaths, respectively,of 1 mm diameter were resistance spot weld to the outside of the fuel rod cladding. For the pre-irradiated test specimens, welding had to be done under hot-cell conditions, i.e. under remote handling. In order to prevent the formation of eutectics between zirconium and the chemical elements of the thermocouple sheath at elevated temperatures, the thermocouples were covered with a platinum jacket of 1.4 mm outside diameter swaged onto the sheath in the area of the measuring junction. This thermocouple design has worked satisfactorily in the in-pile experiments performed in a steam atmosphere. Even in the heatup phase, in which cladding temperatures up to 1050 0 C were reached, only very few failures occured. This good performance is to a great part due to a careful control and a thorough inspection of the thermocouples. (orig.) [de

  20. Core exit thermocouple upgrade at Zion station

    International Nuclear Information System (INIS)

    Ulinski, T.M.; Ferg, D.A.

    1989-01-01

    Following the Three Mile Island accident, the ability of the core exit thermocouple (CET) system to monitor reactor core conditions and core cooling status became a requirement of the U.S. Nuclear Regulatory Commission (NRC). Since the thermocouple system at Zion station was not originally required for postaccident monitoring, Commonwealth Edison Company (CECo) committed to upgrading the CET system and to installing a subcooling margin monitoring (SMM) system. The significance of this commitment was that CECo proposed to accomplish the upgrade effort using internal resources and by developing the required in-house expertise instead of procuring integrated packages from several nuclear steam supply system vendors. The result was that CECo was able to demonstrate a number of new capabilities and unique design features with a significant cost savings. These included a qualified connector with an integral thermocouple cold-reference junction temperature compensation; the design, assembly, testing, and installation of a seismically qualified class 1E microprocessor; a commercial-grade dedication/upgrade process for safety-related hardware; a human factors review capability, and a verification and validation program for safety-related software. A discussion of these new capabilities and details of the design features is presented in this paper

  1. Pitfalls in the assessment of radioresponse as determined by tumor regression. Consideration based on the location and histologic constitution of tumors

    Energy Technology Data Exchange (ETDEWEB)

    Ohara, Kiyoshi; Shimizu, Wakako; Itai, Yuji [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine

    2000-05-01

    To prove the following hypotheses regarding tumor shrinkage after radiotherapy. Tumors located on an outer tissue surface, e.g. esophageal tumors shrink faster than parenchymal tumors, e.g. lymph-node metastasis, because two clearance mechanisms, exfoliation and absorption, can operate in the former type of tumors whereas only absorption can function in the latter. Tumors which are being controlled do not necessarily respond completely, because tumors are constituted not only of tumor cells but also stromal tissues that are difficult to be absorbed. Long-term shrinkage patterns of a parenchymal tumor were determined by using 18 curatively irradiated hepatomas. Preoperatively irradiated thymomas (10) and lymph-node metastases (37) from head and neck cancers were examined histopathologically. Twenty-one esophageal cancers were used for intra-patient response comparison between the primary disease and the lymph-node metastases. Shrinkage patterns were generally biphasic: rapid exponential regression followed by a plateau phase. Histologically, thymomas generally consisted of predominant fibrous tissues and few remaining tumor cells. Radioresponse did not predict the presence of remaining cancer cells in the lymph nodes. Esophageal-cancer radiorespone was always higher for the primary disease than the lymph-node metastases. The location and histologic constitution of tumors must be taken into account in predicting radiocurability using radioresponse. (author)

  2. Failure of sheathed thermocouples due to thermal cycling

    International Nuclear Information System (INIS)

    Anderson, R.L.; Ludwig, R.L.

    1982-03-01

    Open circuit failures (up to 100%) in small-diameter thermocouples used in electrically heated nuclear fuel rod simulator prototypes during thermal cycling tests were investigated to determine the cause(s) of the failures. The experiments conducted to determine the relative effects of differential thermal expansion, wire size, grain size, and manufacturing technology are described. It was concluded that the large grain size and embrittlement which result from certain common manufacturing annealing and drawing procedures were a major contributing factor in the breakage of the thermocouple wires

  3. Racial Variations in Prostate Cancer Molecular Subtypes and Androgen Receptor Signaling Reflect Anatomic Tumor Location.

    Science.gov (United States)

    Faisal, Farzana A; Sundi, Debasish; Tosoian, Jeffrey J; Choeurng, Voleak; Alshalalfa, Mohammed; Ross, Ashley E; Klein, Eric; Den, Robert; Dicker, Adam; Erho, Nicholas; Davicioni, Elai; Lotan, Tamara L; Schaeffer, Edward M

    2016-07-01

    Prostate cancer (PCa) subtypes based on ETS gene expression have been described. Recent studies suggest there are racial differences in tumor location, with PCa located anteriorly more often among African-American (AA) compared to Caucasian-American (CA) men. In this retrospective analysis of a multi-institutional cohort treated by radical prostatectomy (179 CA, 121 AA), we evaluated associations among molecular subtype, race, anatomic tumor location, and androgen receptor (AR) signaling. Subtype (m-ERG(+), m-ETS(+), m-SPINK1(+), or triple-negative) was determined using distribution-based outlier analysis. AR signaling was investigated using gene expression profiling of canonical AR targets. m-ERG(+) was more common in CA than AA men (47% vs 22%, pprostate cancer molecular subtypes, and tumor location. Location-specific differences in androgen regulation may further underlie these relationships. Copyright © 2015. Published by Elsevier B.V.

  4. The transient response for different types of erodable surface thermocouples using finite element analysis

    Directory of Open Access Journals (Sweden)

    Mohammed Hussein

    2007-01-01

    Full Text Available The transient response of erodable surface thermocouples has been numerically assessed by using a two dimensional finite element analysis. Four types of base metal erodable surface thermocouples have been examined in this study, included type-K (alumel-chromel, type-E (chromel-constantan, type-T (copper-constantan, and type-J (iron-constantan with 50 mm thick- ness for each. The practical importance of these types of thermocouples is to be used in internal combustion engine studies and aerodynamics experiments. The step heat flux was applied at the surface of the thermocouple model. The heat flux from the measurements of the surface temperature can be commonly identified by assuming that the heat transfer within these devices is one-dimensional. The surface temperature histories at different positions along the thermocouple are presented. The normalized surface temperature histories at the center of the thermocouple for different types at different response time are also depicted. The thermocouple response to different heat flux variations were considered by using a square heat flux with 2 ms width, a sinusoidal surface heat flux variation width 10 ms period and repeated heat flux variation with 2 ms width. The present results demonstrate that the two dimensional transient heat conduction effects have a significant influence on the surface temperature history measurements made with these devices. It was observed that the surface temperature history and the transient response for thermocouple type-E are higher than that for other types due to the thermal properties of this thermocouple. It was concluded that the thermal properties of the surrounding material do have an impact, but the properties of the thermocouple and the insulation materials also make an important contribution to the net response.

  5. Lifetime improvement of sheathed thermocouples for use in high-temperature and thermal transient operations

    International Nuclear Information System (INIS)

    McCulloch, R.W.; Clift, J.H.

    1982-01-01

    Premature failure of small-diameter, magnesium-oxide-insulated sheathed thermocouples occurred when they were placed within nuclear fuel rod simulators (FRSs) to measure high temperatures and to follow severe thermal transients encountered during simulation of nuclear reactor accidents in Oak Ridge National Laboratory (ORNL) thermal-hydraulic test facilities. Investigation of thermally cycled thermocouples yielded three criteria for improvement of thermocouple lifetime: (1) reduction of oxygen impurities prior to and during their fabrication, (2) refinement of thermoelement grain size during their fabrication, and (3) elimination of prestrain prior to use above their recrystallization temperature. The first and third criteria were satisfied by improved techniques of thermocouple assembly and by a recovery anneal prior to thermocouple use

  6. Dosimetry at the location of secondary tumors after radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Baas, H W; Davelaar, J J; Broerse, J J; Noordijk, E M [University Hospital, Leiden (Netherlands). Dept. of Clinical Oncology

    1995-12-01

    After a latency period of many years the incidence of a secondary tumor is considered a serious late effect of radiotherapy. Analysis of about 200 patients, treated by radiotherapy for Hodgkin`s disease in our hospital, shows an actuarial risk for the incidence of a secondary tumor of about 7% after 10 years. The chance of tumor induction depends on the dose at the location of the tumor and therefore a good dose estimation is mandatory. Radiotherapy was given with Co-60 in the early years and with linear accelerators thereafter, exposing the target areas to 36 - 40 Gy. For dose estimations at the penumbra and outside the beam, where tumor incidence is expected to be high, we used a.o. Monte Carlo calculations. We developed an EGS4 computer simulation for a treatment beam from a linear accelerator irradiating a mathematical phantom representing the patient geometry (GSF ADAM phantom). The isodose curves at certain energies were obtained for a water phantom and fitted quite well with measurements. In addition to Monte Carlo calculations we also used existing treatment planning systems. The dose estimations of a number of patients and the derived risk per unit of dose, which is important for both radiotherapy as well as radiation protection in general, is discussed.

  7. Structural evaluation of thermocouple probes for 241-AZ-101 waste tank

    International Nuclear Information System (INIS)

    Kanjilal, S.K.

    1994-01-01

    This document reports on the structural analysis of the thermocouple probe to be installed in 241-AZ-101 waste tank. The thermocouple probe is analyzed for normal pump mixing operation and potential earthquake induced loads required by the Hanford Site Design Criteria SDC-4.1

  8. Structural evaluation of thermocouple probes for 241-AZ-101 waste tank

    Energy Technology Data Exchange (ETDEWEB)

    Kanjilal, S.K.

    1994-12-06

    This document reports on the structural analysis of the thermocouple probe to be installed in 241-AZ-101 waste tank. The thermocouple probe is analyzed for normal pump mixing operation and potential earthquake induced loads required by the Hanford Site Design Criteria SDC-4.1.

  9. An experimental study of the effect of external thermocouples on rewetting during reflood

    International Nuclear Information System (INIS)

    Shires, G.L.; Butcher, A.A.; Carpenter, B.G.; McCune, D.S.; Pearson, K.G.

    1980-04-01

    The validation of computer codes used for PWR safety assessment often depends upon experiments carried out with either real fuel pins or electrically heated fuel pin simulators. In some cases, and this applies particularly to in-pile tests, temperatures are measured by means of sheathed thermocouples attached externally to the pins and this raises the question of the possible effect of such thermocouples on the two phase hydraulics and heat transfer which are being studied. This paper describes the experiments which subjected two realistic fuel pin simulators, one with and one without external thermocouples, to identical bottom flooding conditions. They demonstrate very clearly that external thermocouples act as preferential rewetting sites and thereby increase the rate of propagation of the quench front. In the view of the authors of this paper the facts described raise serious doubts about the validity of rewetting data obtained from experiments employing external thermocouples. (U.K.)

  10. A Modified Design of a Thermocouple Based Digital Temperature Indicator with Opto-Isolation

    Directory of Open Access Journals (Sweden)

    S. C. BERA

    2008-01-01

    Full Text Available In the conventional thermocouple based digital temperature indicator the millivolt signal obtained from a thermocouple is first amplified and then converted into a digital signal by using analog-to-digital converter (ADC. This digital signal is then indicated as digital display of temperature using digital counter circuit or microprocessor/microcontroller based circuitry. In the present paper a modified AD conversion technique along with opto-isolation is used to indicate digitally the temperature without using any conventional analog-to-digital converter. The theory and design of the measuring technique are described in the paper. The non-linearity of thermocouple is eliminated by using look-up table within software program. The performance of the circuit has been experimentally tested by using mV input signal instead of a thermocouple as well as using a K-type thermocouple. The experimental results are reported in the paper.

  11. Thermoelectric properties of currently available Au/Pt thermocouples related to the valid reference function

    Directory of Open Access Journals (Sweden)

    Edler F.

    2015-01-01

    Full Text Available Au/Pt thermocouples are considered to be an alternative to High Temperature Standard Platinum Resistance Thermometers (HTSPRTs for realizing temperatures according to the International Temperature Scale of 1990 (ITS-90 in the temperature range between aluminium (660.323 °C and silver (961.78 °C. The original aim of this work was to develop and to validate a new reference function for Au/Pt thermocouples which reflects the properties of presently commercially available Au and Pt wires. The thermoelectric properties of 16 Au/Pt thermocouples constructed at different National Metrological Institutes by using wires from different suppliers and 4 commercially available Au/Pt thermocouples were investigated. Most of them exhibit significant deviations from the current reference function of Au/Pt thermocouples caused by the poor performance of the Au-wires available. Thermoelectric homogeneity was investigated by measuring immersion profiles during freezes at the freezing point of silver and in liquid baths. The thermoelectric inhomogeneities were found to be one order of magnitude larger than those of Au/Pt thermocouples of the Standard Reference Material® (SRM® 1749. The improvement of the annealing procedure of the gold wires is a key process to achieve thermoelectric homogeneities in the order of only about (2–3 mK, sufficient to replace the impracticable HTSPRTs as interpolation instruments of the ITS-90. Comparison measurements of some of the Au/Pt thermocouples against a HTSPRT and an absolutely calibrated radiation thermometer were performed and exhibit agreements within the expanded measurement uncertainties. It has been found that the current reference function of Au/Pt thermocouples reflects adequately the thermoelectric properties of currently available Au/Pt thermocouples.

  12. A correlative optical microscopy and scanning electron microscopy approach to locating nanoparticles in brain tumors.

    Science.gov (United States)

    Kempen, Paul J; Kircher, Moritz F; de la Zerda, Adam; Zavaleta, Cristina L; Jokerst, Jesse V; Mellinghoff, Ingo K; Gambhir, Sanjiv S; Sinclair, Robert

    2015-01-01

    The growing use of nanoparticles in biomedical applications, including cancer diagnosis and treatment, demands the capability to exactly locate them within complex biological systems. In this work a correlative optical and scanning electron microscopy technique was developed to locate and observe multi-modal gold core nanoparticle accumulation in brain tumor models. Entire brain sections from mice containing orthotopic brain tumors injected intravenously with nanoparticles were imaged using both optical microscopy to identify the brain tumor, and scanning electron microscopy to identify the individual nanoparticles. Gold-based nanoparticles were readily identified in the scanning electron microscope using backscattered electron imaging as bright spots against a darker background. This information was then correlated to determine the exact location of the nanoparticles within the brain tissue. The nanoparticles were located only in areas that contained tumor cells, and not in the surrounding healthy brain tissue. This correlative technique provides a powerful method to relate the macro- and micro-scale features visible in light microscopy with the nanoscale features resolvable in scanning electron microscopy. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Magnetic tunnel junction thermocouple for thermoelectric power harvesting

    Science.gov (United States)

    Böhnert, T.; Paz, E.; Ferreira, R.; Freitas, P. P.

    2018-05-01

    The thermoelectric power generated in magnetic tunnel junctions (MTJs) is determined as a function of the tunnel barrier thickness for a matched electric circuit. This study suggests that lower resistance area product and higher tunnel magnetoresistance will maximize the thermoelectric power output of the MTJ structures. Further, the thermoelectric behavior of a series of two MTJs, a MTJ thermocouple, is investigated as a function of its magnetic configurations. In an alternating magnetic configurations the thermovoltages cancel each other, while the magnetic contribution remains. A large array of MTJ thermocouples could amplify the magnetic thermovoltage signal significantly.

  14. Thermocouple Errors when Mounted on Cylindrical Surfaces in Abnormal Thermal Environments.

    Energy Technology Data Exchange (ETDEWEB)

    Nakos, James T. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Suo-Anttila, Jill M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Zepper, Ethan T. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Koenig, Jerry J [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Valdez, Vincent A. [ECI Inc., Albuquerque, NM (United States)

    2017-05-01

    Mineral-insulated, metal-sheathed, Type-K thermocouples are used to measure the temperature of various items in high-temperature environments, often exceeding 1000degC (1273 K). The thermocouple wires (chromel and alumel) are protected from the harsh environments by an Inconel sheath and magnesium oxide (MgO) insulation. The sheath and insulation are required for reliable measurements. Due to the sheath and MgO insulation, the temperature registered by the thermocouple is not the temperature of the surface of interest. In some cases, the error incurred is large enough to be of concern because these data are used for model validation, and thus the uncertainties of the data need to be well documented. This report documents the error using 0.062" and 0.040" diameter Inconel sheathed, Type-K thermocouples mounted on cylindrical surfaces (inside of a shroud, outside and inside of a mock test unit). After an initial transient, the thermocouple bias errors typically range only about +-1-2% of the reading in K. After all of the uncertainty sources have been included, the total uncertainty to 95% confidence, for shroud or test unit TCs in abnormal thermal environments, is about +-2% of the reading in K, lower than the +-3% typically used for flat shrouds. Recommendations are provided in Section 6 to facilitate interpretation and use of the results. .

  15. Tumor histology and location predict deep nuclei toxicity: Implications for late effects from focal brain irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Plaga, Alexis; Shields, Lisa B.E. [Norton Neuroscience Institute, Louisville, KY (United States); Sun, David A.; Vitaz, Todd W. [Norton Neuroscience Institute, Louisville, KY (United States); Brain Tumor Center, Norton Healthcare, Louisville, KY (United States); Spalding, Aaron C., E-mail: acspalding1@gmail.com [Brain Tumor Center, Norton Healthcare, Louisville, KY (United States); Norton Cancer Institute, Radiation Center, Kosair Children' s Hospital, Louisville, KY (United States)

    2012-10-01

    Normal tissue toxicity resulting from both disease and treatment is an adverse side effect in the management of patients with central nervous system malignancies. We tested the hypothesis that despite these improvements, certain tumors place patients at risk for neurocognitive, neuroendocrine, and neurosensory late effects. Defining patient groups at risk for these effects could allow for development of preventive strategies. Fifty patients with primary brain tumors underwent radiation planning with magnetic resonance imaging scan and computed tomography datasets. Organs at risk (OAR) responsible for neurocognitive, neuroendocrine, and neurosensory function were defined. Inverse-planned intensity-modulated radiation therapy was optimized with priority given to target coverage while penalties were assigned to exceeding normal tissue tolerances. Tumor laterality, location, and histology were compared with OAR doses, and analysis of variance was performed to determine the significance of any observed correlation. The ipsilateral hippocampus exceeded dose limits in frontal (74%), temporal (94%), and parietal (100%) lobe tumor locations. The contralateral hippocampus was at risk in the following tumor locations: frontal (53%), temporal (83%), or parietal (50%) lobe. Patients with high-grade glioma were at risk for ipsilateral (88%) and contralateral (73%) hippocampal damage (P <0.05 compared with other histologies). The pituitary gland and hypothalamus exceeded dose tolerances in patients with pituitary tumors (both 100%) and high-grade gliomas (50% and 75%, P <0.05 compared with other histologies), respectively. Despite application of modern radiation therapy, certain tumor locations and histologies continue to place patients at risk for morbidity. Patients with high-grade gliomas or tumors located in the frontal, temporal, or parietal lobes are at risk for neurocognitive decline, likely because of larger target volumes and higher radiation doses. Data from this study

  16. Tumor histology and location predict deep nuclei toxicity: Implications for late effects from focal brain irradiation

    International Nuclear Information System (INIS)

    Plaga, Alexis; Shields, Lisa B.E.; Sun, David A.; Vitaz, Todd W.; Spalding, Aaron C.

    2012-01-01

    Normal tissue toxicity resulting from both disease and treatment is an adverse side effect in the management of patients with central nervous system malignancies. We tested the hypothesis that despite these improvements, certain tumors place patients at risk for neurocognitive, neuroendocrine, and neurosensory late effects. Defining patient groups at risk for these effects could allow for development of preventive strategies. Fifty patients with primary brain tumors underwent radiation planning with magnetic resonance imaging scan and computed tomography datasets. Organs at risk (OAR) responsible for neurocognitive, neuroendocrine, and neurosensory function were defined. Inverse-planned intensity-modulated radiation therapy was optimized with priority given to target coverage while penalties were assigned to exceeding normal tissue tolerances. Tumor laterality, location, and histology were compared with OAR doses, and analysis of variance was performed to determine the significance of any observed correlation. The ipsilateral hippocampus exceeded dose limits in frontal (74%), temporal (94%), and parietal (100%) lobe tumor locations. The contralateral hippocampus was at risk in the following tumor locations: frontal (53%), temporal (83%), or parietal (50%) lobe. Patients with high-grade glioma were at risk for ipsilateral (88%) and contralateral (73%) hippocampal damage (P <0.05 compared with other histologies). The pituitary gland and hypothalamus exceeded dose tolerances in patients with pituitary tumors (both 100%) and high-grade gliomas (50% and 75%, P <0.05 compared with other histologies), respectively. Despite application of modern radiation therapy, certain tumor locations and histologies continue to place patients at risk for morbidity. Patients with high-grade gliomas or tumors located in the frontal, temporal, or parietal lobes are at risk for neurocognitive decline, likely because of larger target volumes and higher radiation doses. Data from this study

  17. Temperature distribution in target tumor tissue and photothermal tissue destruction during laser immunotherapy

    Science.gov (United States)

    Doughty, Austin; Hasanjee, Aamr; Pettitt, Alex; Silk, Kegan; Liu, Hong; Chen, Wei R.; Zhou, Feifan

    2016-03-01

    Laser Immunotherapy is a novel cancer treatment modality that has seen much success in treating many different types of cancer, both in animal studies and in clinical trials. The treatment consists of the synergistic interaction between photothermal laser irradiation and the local injection of an immunoadjuvant. As a result of the therapy, the host immune system launches a systemic antitumor response. The photothermal effect induced by the laser irradiation has multiple effects at different temperature elevations which are all required for optimal response. Therefore, determining the temperature distribution in the target tumor during the laser irradiation in laser immunotherapy is crucial to facilitate the treatment of cancers. To investigate the temperature distribution in the target tumor, female Wistar Furth rats were injected with metastatic mammary tumor cells and, upon sufficient tumor growth, underwent laser irradiation and were monitored using thermocouples connected to locally-inserted needle probes and infrared thermography. From the study, we determined that the maximum central tumor temperature was higher for tumors of less volume. Additionally, we determined that the temperature near the edge of the tumor as measured with a thermocouple had a strong correlation with the maximum temperature value in the infrared camera measurement.

  18. An Innovative Flow-Measuring Device: Thermocouple Boundary Layer Rake

    Science.gov (United States)

    Hwang, Danny P.; Fralick, Gustave C.; Martin, Lisa C.; Wrbanek, John D.; Blaha, Charles A.

    2001-01-01

    An innovative flow-measuring device, a thermocouple boundary layer rake, was developed. The sensor detects the flow by using a thin-film thermocouple (TC) array to measure the temperature difference across a heater strip. The heater and TC arrays are microfabricated on a constant-thickness quartz strut with low heat conductivity. The device can measure the velocity profile well into the boundary layer, about 65 gm from the surface, which is almost four times closer to the surface than has been possible with the previously used total pressure tube.

  19. Low drift type N thermocouples in out-of-pile advanced gas reactor mock-up test: metallurgical analysis

    International Nuclear Information System (INIS)

    Scervini, M.; Palmer, J.; Haggard, D.C.; Swank, W.D.

    2015-01-01

    Thermocouples are the most commonly used sensors for temperature measurement in nuclear reactors. They are crucial for the control of current nuclear reactors and for the development of GEN IV reactors. In nuclear applications thermocouples are strongly affected by intense neutron fluxes. As a result of the interaction with neutrons, the thermoelements of the thermocouples undergo transmutation, which produces a time dependent change in composition and, as a consequence, a time dependent drift of the thermocouple signal. Thermocouple drift can be very significant for in-pile temperature measurements and may render the temperature sensors unreliable after exposure to nuclear radiation for relatively short times compared to the life required for temperature sensors in nuclear applications. Previous experiences with type K thermocouples in nuclear reactors have shown that they are affected by neutron irradiation only to a limited extent. Similarly type N thermocouples are expected to be only slightly affected by neutron fluxes. Currently the use of Nickel based thermocouples is limited to temperatures lower than 1000 deg. C due to drift related to phenomena other than nuclear irradiation. As part of a collaboration between Idaho National Laboratory (INL) and the University of Cambridge a variety of Type N thermocouples have been exposed at INL in an Advanced Gas Reactor mock-up test at 1150 deg. C for 2000 h, 1200 deg. C for 2000 h, 125 deg. C for 200 h and 1300 deg. C for 200 h, and later analysed metallurgically at the University of Cambridge. The use of electron microscopy allows to identify the metallurgical changes occurring in the thermocouples during high temperature exposure and correlate the time dependent thermocouple drift with the microscopic changes experienced by the thermoelements of different thermocouple designs. In this paper conventional Inconel 600 sheathed type N thermocouples and a type N using a customized sheath developed at the University of

  20. Low drift type N thermocouples in out-of-pile advanced gas reactor mock-up test: metallurgical analysis

    Energy Technology Data Exchange (ETDEWEB)

    Scervini, M. [University of Cambridge, Department of Materials Science and Metallurgy, 27 Charles Babbage Road, CB30FS Cambridge, (United Kingdom); Palmer, J.; Haggard, D.C.; Swank, W.D. [Idaho National Laboratory, Idaho Falls, ID 83415-3840, (United States)

    2015-07-01

    Thermocouples are the most commonly used sensors for temperature measurement in nuclear reactors. They are crucial for the control of current nuclear reactors and for the development of GEN IV reactors. In nuclear applications thermocouples are strongly affected by intense neutron fluxes. As a result of the interaction with neutrons, the thermoelements of the thermocouples undergo transmutation, which produces a time dependent change in composition and, as a consequence, a time dependent drift of the thermocouple signal. Thermocouple drift can be very significant for in-pile temperature measurements and may render the temperature sensors unreliable after exposure to nuclear radiation for relatively short times compared to the life required for temperature sensors in nuclear applications. Previous experiences with type K thermocouples in nuclear reactors have shown that they are affected by neutron irradiation only to a limited extent. Similarly type N thermocouples are expected to be only slightly affected by neutron fluxes. Currently the use of Nickel based thermocouples is limited to temperatures lower than 1000 deg. C due to drift related to phenomena other than nuclear irradiation. As part of a collaboration between Idaho National Laboratory (INL) and the University of Cambridge a variety of Type N thermocouples have been exposed at INL in an Advanced Gas Reactor mock-up test at 1150 deg. C for 2000 h, 1200 deg. C for 2000 h, 125 deg. C for 200 h and 1300 deg. C for 200 h, and later analysed metallurgically at the University of Cambridge. The use of electron microscopy allows to identify the metallurgical changes occurring in the thermocouples during high temperature exposure and correlate the time dependent thermocouple drift with the microscopic changes experienced by the thermoelements of different thermocouple designs. In this paper conventional Inconel 600 sheathed type N thermocouples and a type N using a customized sheath developed at the University of

  1. Establishment of the Co-C Eutectic Fixed-Point Cell for Thermocouple Calibrations at NIMT

    Science.gov (United States)

    Ongrai, O.; Elliott, C. J.

    2017-08-01

    In 2015, NIMT first established a Co-C eutectic temperature reference (fixed-point) cell measurement capability for thermocouple calibration to support the requirements of Thailand's heavy industries and secondary laboratories. The Co-C eutectic fixed-point cell is a facility transferred from NPL, where the design was developed through European and UK national measurement system projects. In this paper, we describe the establishment of a Co-C eutectic fixed-point cell for thermocouple calibration at NIMT. This paper demonstrates achievement of the required furnace uniformity, the Co-C plateau realization and the comparison data between NIMT and NPL Co-C cells by using the same standard Pt/Pd thermocouple, demonstrating traceability. The NIMT measurement capability for noble metal type thermocouples at the new Co-C eutectic fixed point (1324.06°C) is estimated to be within ± 0.60 K (k=2). This meets the needs of Thailand's high-temperature thermocouple users—for which previously there has been no traceable calibration facility.

  2. Tumor histology and location predict deep nuclei toxicity: Implications for late effects from focal brain irradiation.

    Science.gov (United States)

    Plaga, Alexis; Shields, Lisa B E; Sun, David A; Vitaz, Todd W; Spalding, Aaron C

    2012-01-01

    Normal tissue toxicity resulting from both disease and treatment is an adverse side effect in the management of patients with central nervous system malignancies. We tested the hypothesis that despite these improvements, certain tumors place patients at risk for neurocognitive, neuroendocrine, and neurosensory late effects. Defining patient groups at risk for these effects could allow for development of preventive strategies. Fifty patients with primary brain tumors underwent radiation planning with magnetic resonance imaging scan and computed tomography datasets. Organs at risk (OAR) responsible for neurocognitive, neuroendocrine, and neurosensory function were defined. Inverse-planned intensity-modulated radiation therapy was optimized with priority given to target coverage while penalties were assigned to exceeding normal tissue tolerances. Tumor laterality, location, and histology were compared with OAR doses, and analysis of variance was performed to determine the significance of any observed correlation. The ipsilateral hippocampus exceeded dose limits in frontal (74%), temporal (94%), and parietal (100%) lobe tumor locations. The contralateral hippocampus was at risk in the following tumor locations: frontal (53%), temporal (83%), or parietal (50%) lobe. Patients with high-grade glioma were at risk for ipsilateral (88%) and contralateral (73%) hippocampal damage (P <0.05 compared with other histologies). The pituitary gland and hypothalamus exceeded dose tolerances in patients with pituitary tumors (both 100%) and high-grade gliomas (50% and 75%, P <0.05 compared with other histologies), respectively. Despite application of modern radiation therapy, certain tumor locations and histologies continue to place patients at risk for morbidity. Patients with high-grade gliomas or tumors located in the frontal, temporal, or parietal lobes are at risk for neurocognitive decline, likely because of larger target volumes and higher radiation doses. Data from this study

  3. Degradation by radiation of the response of a thermocouple of a fuel element

    International Nuclear Information System (INIS)

    Rodriguez V, A.

    1994-01-01

    In the TRIGA Mark III Reactor of the National Institute of Nuclear Research, is necessary to use an instrumented fuel element for measurement the fuel temperature during pulses of power. This fuel element is exposed to daily temperature gradient of order to 390 Centigrade degrees in normal condition of reactor operation at 1 MW. The experience which this instrumented fuel elements is that useful life of the thermocouples is less then the fuel, because they show important changes in their chemistry composition and electrical specifications, until the point they don't give any response. So is necessary to know the factors that influenced in the shortening of the thermocouples life. The change in composition affects the thermocouple calibration depends on where the changes take place relative to the temperature gradient. The change will be dependent on the neutron flux and so the value of the neutron flux may be used as a measure or the composition change. If there is no neutron flux within the temperature gradient, there will be no composition change, and so the thermocouple calibration will no change. If the neutron flux varies within the region in which a temperature gradients exists, the composition of the thermocouple will vary and the calibration will change. But the maximum change in calibration will occur if the neutron flux is high and constant within the region of the temperature gradient. In this case, a composition change takes place which is uniform throughout the gradient and so the emf output can be expected to change. In this reactor, the thermocouples are in the second case. Then, the relative position of the thermal and neutron flux gradients are the most important factor that explain the composition change after or 2,500 times of exposing the thermocouples to the temperature gradients of order to 390 Centigrade degrees. (Author)

  4. Evaluation of thermocouple fin effect in cladding surface temperature measurement during film boiling

    International Nuclear Information System (INIS)

    Tsuruta, Takaharu; Fujishiro, Toshio

    1984-01-01

    Thermocouple fin effect on surface temperature measurement of a fuel rod has been studied at elevated wall temperatures under film boiling condition in a reactivity initiated accident (RIA) situation. This paper presents an analytical equation to evaluate temperature drops caused by the thermocouple wires attached to cladding surface. The equation yielded the local temperature drop at measuring point depending on thermocouple diameter, cladding temperature, coolant flow condition and vapor film thickness. The temperature drops by the evaluating equation were shown in cases of free and forced convection conditions. The analytical results were compared with the measured data for various thermocouple sizes, and also with the estimated maximum cladding temperature based on the oxidation layer thickness in the cladding outer surface. It was concluded that the temperature drops at above 1,000 0 C in cladding temperature were around 120 and 150 0 C for 0.2 and 0.3 mm diameter Pt-Pt.Rh thermocouples, respectively, under a stagnant coolant condition. The fin effect increases with the decrease of vapor film thickness such as under forced flow cooling or at near the quenching point. (author)

  5. Thermocouples calibration and analysis of the influence of the length of the sensor coating

    International Nuclear Information System (INIS)

    Noriega, M; Ramírez, R; López, R; Vaca, M; Morales, J; Terres, H; Lizardi, A; Chávez, S

    2015-01-01

    This paper presents the design and construction of a lab prototype, with a much lower cost compared to the ones commercially sold, enabling the manufacture of thermocouples which are then calibrated to verify their functionality and acceptance. We also analyze the influence of the external insulation over the wires, to determine whether it influences temperature measurement. The tested lengths ranged from 0.00 m up to 0.030 m. The thermocouple was compared against the behavior of a thermocouple of the same type that was purchased with a commercial supplier. The obtained measurement showed less than 1 °C difference in some points. This makes the built thermocouple reliable, since the standard allows a difference of up to 2.2 °C

  6. Organizing Thrombus Mimicking a Cardiac Tumor Located at the Mitral-Aortic Intervalvular Fibrosa

    Directory of Open Access Journals (Sweden)

    Ji Seong Lee

    2016-02-01

    Full Text Available Thrombosis at the left ventricular outflow tract occurs without any detectable heart disease or predisposing factors only extremely rarely. A 48-year-old male visited Konkuk University Medical Center with loss of consciousness one month prior to presentation. Before he visited our hospital, he had been diagnosed with a cardiac tumor, which was located between the left atrium and posterior aortic root, and which was adjacent to both the aortic and mitral valves. Cardiac transplantation was recommended at the other hospital because of the high risk of cardiac dysfunction induced by both aortic and mitral valvular dysfunction after surgical resection. Based on preoperative transthoracic echocardiography, cardiac computed tomography, cardiac magnetic resonance imaging, and intraoperative transesophageal echocardiography, we considered it to be a benign tumor. Complete resection was achieved and the pathology confirmed organizing thrombus. We report a case of organizing thrombus mimicking a cardiac tumor, which was located at the mitral-aortic intervalvular fibrosa of the left ventricular outflow tract without any heart disease.

  7. Primary tumor location predicts poor clinical outcome with cetuximab in RAS wild-type metastatic colorectal cancer.

    Science.gov (United States)

    Kim, Dalyong; Kim, Sun Young; Lee, Ji Sung; Hong, Yong Sang; Kim, Jeong Eun; Kim, Kyu-Pyo; Kim, Jihun; Jang, Se Jin; Yoon, Young-Kwang; Kim, Tae Won

    2017-11-23

    In metastatic colorectal cancer, the location of the primary tumor has been suggested to have biological significance. In this study, we investigated whether primary tumor location affects cetuximab efficacy in patients with RAS wild-type metastatic colorectal cancer. Genotyping by the SequenomMassARRAY technology platform (OncoMap) targeting KRAS, NRAS, PIK3CA, and BRAF was performed in tumors from 307 patients who had been given cetuximab as salvage treatment. Tumors with mutated RAS (KRAS or NRAS; n = 127) and those with multiple primary location (n = 10) were excluded. Right colon cancer was defined as a tumor located in the proximal part to splenic flexure. A total of 170 patients were included in the study (right versus left, 23 and 147, respectively). Patients with right colon cancer showed more mutated BRAF (39.1% vs. 5.4%), mutated PIK3CA (13% vs. 1.4%), poorly differentiated tumor (17.4% vs. 3.4%), and peritoneal involvement (26.1% vs. 8.8%) than those with left colon and rectal cancer. Right colon cancer showed poorer progression-free survival (2.0 vs.5.0 months, P = 0.002) and overall survival (4.1 months and 13.0 months, P < 0.001) than the left colon and rectal cancer. By multivariable analysis, BRAF mutation, right colon primary, poorly differentiated histology, and peritoneal involvement were associated with risk of death. In RAS wild-type colon cancer treated with cetuximab as salvage treatment, right colon primary was associated with poorer survival outcomes than left colon and rectal cancer.

  8. Direct Measurement of Neutral/Ion Beam Power using Thermocouple Analysis

    International Nuclear Information System (INIS)

    Day, I.; Gee, S.

    2006-01-01

    Modern Neutral Beam Injection systems such as those used on JET and MAST routinely use thermocouples embedded close to the surface of beam stopping elements, such as calorimeters and ion dumps, coupled to high speed data acquisition systems to determine beam profile and position from temperature rise data. With the availability of low cost data acquisition and storage systems it is now possible to record data from all thermocouples in a fully instrumented calorimeter or ion dump on 20 ms timescales or better. This sample rate is sufficiently fast to enable the thermocouple data to be used to calculate the incident power density from 1d heat transfer theory. This power density data coupled with appropriate Gaussian fits enables the determination of the 2d beam profile and thus allows an instantaneous and direct measurement of beam power. The theory and methodology required to analyse the fast thermocouple data from the MAST calorimeter and residual ion dump thermocouples is presented and direct measurements of beam power density are demonstrated. The power of desktop computers allows such analysis to be carried out virtually instantaneously. The methods used to automate this analysis are discussed in detail. A code, utilising the theory and methodology, has been developed to allow immediate measurements of beam power on a pulse by pulse basis. The uncertainty in determining the beam power density is shown to be less than 10 %. This power density data is then fitted to a 2d Gaussian beam profile and integrated to establish the total beam power. Results of this automated analysis for the neutral beam and residual ion power of the MAST duopigatron and PINI NBI systems are presented. This technology could be applied to a beam power safety interlock system. The application to a beam shine through protection system for the inner wall of the JET Tokamak is discussed as an example. (author)

  9. Thermal Recovery from Cold-Working in Type K Bare-Wire Thermocouples

    Science.gov (United States)

    Greenen, A. D.; Webster, E. S.

    2017-12-01

    Cold-working of most thermocouples has a significant, direct impact on the Seebeck coefficient which can lead to regions of thermoelectric inhomogeneity and accelerated drift. Cold-working can occur during the wire swaging process, when winding the wire onto a bobbin, or during handling by the end user—either accidentally or deliberately. Swaging-induced cold-work in thermocouples, if uniformly applied, may result in a high level of homogeneity. However, on exposure to elevated temperatures, the subsequent recovery process from the cold-working can then result in significant drift, and this can in turn lead to erroneous temperature measurements, often in excess of the specified manufacturer tolerances. Several studies have investigated the effects of cold-work in Type K thermocouples usually by bending, or swaging. However, the amount of cold-work applied to the thermocouple is often difficult to quantify, as the mechanisms for applying the strains are typically nonlinear when applied in this fashion. A repeatable level of cold-working is applied to the different wires using a tensional loading apparatus to apply a known yield displacement to the thermoelements. The effects of thermal recovery from cold-working can then be accurately quantified as a function of temperature, using a linear gradient furnace and a high-resolution homogeneity scanner. Variation in these effects due to differing alloy compositions in Type K wire is also explored, which is obtained by sourcing wire from a selection of manufacturers. The information gathered in this way will inform users of Type K thermocouples about the potential consequences of varying levels of cold-working and its impact on the Seebeck coefficient at a range of temperatures between ˜ 70°C and 600° C. This study will also guide users on the temperatures required to rapidly alleviate the effects of cold-working using thermal annealing treatments.

  10. Calibration Technique of the Irradiated Thermocouple using Artificial Neural Network

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Jin Tae; Joung, Chang Young; Ahn, Sung Ho; Yang, Tae Ho; Heo, Sung Ho; Jang, Seo Yoon [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    To correct the signals, the degradation rate of sensors needs to be analyzed, and re-calibration of sensors should be followed periodically. In particular, because thermocouples instrumented in the nuclear fuel rod are degraded owing to the high neutron fluence generated from the nuclear fuel, the periodic re-calibration process is necessary. However, despite the re-calibration of the thermocouple, the measurement error will be increased until next re-calibration. In this study, based on the periodically calibrated temperature - voltage data, an interpolation technique using the artificial neural network will be introduced to minimize the calibration error of the C-type thermocouple under the irradiation test. The test result shows that the calculated voltages derived from the interpolation function have good agreement with the experimental sampling data, and they also accurately interpolate the voltages at arbitrary temperature and neutron fluence. That is, once the reference data is obtained by experiments, it is possible to accurately calibrate the voltage signal at a certain neutron fluence and temperature using an artificial neural network.

  11. Temperature measurement: Development work on noise thermometry and improvement of conventional thermocouples for applications in nuclear process heat (PNP)

    International Nuclear Information System (INIS)

    Brixy, H.; Hecker, R.; Oehmen, J.; Barbonus, P.; Hans, R.

    1982-06-01

    The behaviour was studied of NiCr-Ni sheathed thermocouples (sheath Inconel 600 or Incoloy 800, insulation MgO) in a helium and carbon atmosphere at temperatures of 950-1150 deg. C. All the thermocouples used retained their functional performance. The insulation resistance tended towards a limit value which is dependent on the temperature and quality of the thermocouple. Temperature measurements were loaded with great uncertainty in the temperature range of 950-1150 deg. C. Recalibrations at the temperature of 950 deg. C showed errors of up to 6%. Measuring sensors were developed which consist of a sheathed double thermocouple with a noise resistor positioned between the two hot junctions. Using the noise thermometer it is possible to recalibrate the thermocouple at any time in situ. A helium system with a high temperature experimental area was developed to test the thermocouples and the combined thermocouple-noise thermometer sensors under true experimental conditions

  12. Thermocouple calibration facility for 2900 deg C high temperature and its applications

    International Nuclear Information System (INIS)

    Chen Daolong

    1991-01-01

    The construction and the performance characteristic of a 2900 deg C high temperature thermocouple calibration facility are described. The calibration error analysis is made. The test results of the calibration characteristics of high temperature thermocouples Mo/Nb, W-3Re/W-25Re, and W-1Mo/W-25Mo are given. The test result of temperature dependent resistivity of BeO made by this facility is given

  13. Reply to ''Comment on 'Thermocouple temperature measurements in shock-compressed solids' ''

    International Nuclear Information System (INIS)

    Bloomquist, D.D.; Sheffield, S.A.

    1982-01-01

    We disagree with the interpretation offered in the above comment. The suggestion was made that the anomalously fast response of thin-foil thermocouples reported previously is the result of strain dependence of the thermocouple response and not shock enhanced thermal equilibration. Although the emplacement geometry has a profound effect on the response of embedded thin-foil temperature gauges as noted in the above comment, the evidence presented, along with recent results discussed in this reply, do not support the conclusions presented in the above comment

  14. A preliminary study of factors affecting the calibration stability of the iridium versus iridium-40 percent rhodium thermocouple

    Science.gov (United States)

    Ahmed, Shaffiq; Germain, Edward F.; Daryabeigi, Kamran; Alderfer, David W.; Wright, Robert E.

    1987-01-01

    An iridium versus iridium-40% rhodium thermocouple was studied. Problems associated with the use of this thermocouple for high temperature applications (up to 2000 C) were investigated. The metallurgical studies included X-ray, macroscopic, resistance, and metallographic studies. The thermocouples in the as-received condition from the manufacturer revealed large amounts of internal stress caused by cold working during manufacturing. The thermocouples also contained a large amount of inhomogeneities and segregations. No phase transformations were observed in the alloy up to 1100 C. It was found that annealing the thermocouple at 1800 C for two hours, and then at 1400 C for 2 to 3 hours yielded a fine grain structure, relieving some of the strains, and making the wire more ductile. It was also found that the above annealing procedure stabilized the thermal emf behavior of the thermocouple for application below 1800 C (an improvement from + or - 1% to + or - 0.02% within the range of the test parameters used).

  15. Study on thermocouple attachment in reflood experiments

    International Nuclear Information System (INIS)

    Sugimoto, Jun

    1977-03-01

    The method of thermocouple attachment to a heater rods has been studied for surface temperature measurement in reflood experiments. The method used as far in JAERI's reflood experiments had some possibilities of not estimating exactly the quench times. Various attachment method have been tested and some proved to be effective in the respect. (auth.)

  16. Enterobiasis in Ectopic Locations Mimicking Tumor-Like Lesions

    Directory of Open Access Journals (Sweden)

    Silvio Pampiglione

    2009-01-01

    Full Text Available Both the clinical and the histopathological diagnostic difficulties of oxyuriasis in unusual sites and their importance from a clinical point of view are pointed out. The authors report two ectoptic cases of enterobiasis observed in Northern Italy, one located in a fallopian tube of a 57-year-old woman and the other in a perianal subcutaneous tissue of a 59-year-old man, mimicking tumor-like lesions. The authors take advantage of the occasion to focus the attention of the medical world on this subject, lamenting the scarce importance given to this parasitosis in university courses of medical schools and in medical textbooks as it is incorrectly considered “out-of-fashion.”

  17. Zircaloy-sheathed element rods fitted with thermo-couples

    International Nuclear Information System (INIS)

    Bernardy de Sigoyer, B.; Jacques, F.; Thome, P.

    1963-01-01

    In order to carry out thermal conductivity measurements on UO 2 in conditions similar to those under which fuel rods are used, it was necessary to measure the temperature at the interior of a fuel element sheathed in zircaloy. The temperatures are taken with Thermocoax type thermocouples, that is to say fitted with a very thin sheath of stainless steel or Inconel. It is known also that fusion welding of zircaloy onto stainless steel is impossible and that high temperature welded joints are very difficult because of their aggressiveness. The technique used consists in brazing the thermocouples to relatively large stainless steel parts and then joining these plugs by electron bombardment welding to diffused stainless steel-zircaloy couplings. The properties of these diffused couplings and of the brazed joints were studied; the various stages in the fabrication of the containers are also described. (authors) [fr

  18. R and D advances in high temperature thermocouples for nuclear utilization in severe environment

    International Nuclear Information System (INIS)

    Schley, R.; Blanc, J.Y.

    1984-09-01

    Safety experiments for water reactors in Cadarache have made necessary a research program for developing special thermocouples for use in severe fuel damage conditions (superheated steam). Standard cladding thermocouples (type K, alumina insulated, zircaloy sheathed, O.D. 0.7 mm) must be replaced by others with W3Re versus W25Re legs, Ta sheath protected by a zircaloy outer sheath, and hafnia or thoria insulation. The zircaloy sheath will be sufficient to protect correctly tantalum. Fuel centerline thermocouples have W5Re versus W26Re or W3Re versus W25Re legs, hard-fired thoria insulation and rhenium CVD sheath (O.D. 1.1 mm). A protective ReSi 2 coating is applied. This protection withstands at least 1600 0 C, 45 minutes in steam. Tests are done-concerning: a) materials compatibilities in helium between 1400 0 C and 2000 0 C, b) prototypes qualification (in Saclay or Grenoble), c) determination of errors due to degradation of insulation resistance of thermocouples cables (with magnesia, hafnia, alumina), d) Ir or Re protective coatings by CVD process, other coatings by ionic bombardment, etc... A completely new type of hot junction has been patented. Future works will include: completion of these tests, Mo-Nb alloys thermocouples legs realization withstanding heavy neutronic fluence, and use of ceramics glues

  19. Temperature measurement error due to the effects of time varying magnetic fields on thermocouples with ferromagnetic thermoelements

    International Nuclear Information System (INIS)

    McDonald, D.W.

    1977-01-01

    Thermocouples with ferromagnetic thermoelements (iron, Alumel, Nisil) are used extensively in industry. We have observed the generation of voltage spikes within ferromagnetic wires when the wires are placed in an alternating magnetic field. This effect has implications for thermocouple thermometry, where it was first observed. For example, the voltage generated by this phenomenon will contaminate the thermocouple thermal emf, resulting in temperature measurement error

  20. 78 FR 56174 - In-Core Thermocouples at Different Elevations and Radial Positions in Reactor Core

    Science.gov (United States)

    2013-09-12

    ... 52 [Docket No. PRM-50-105; NRC-2012-0056] In-Core Thermocouples at Different Elevations and Radial Positions in Reactor Core AGENCY: Nuclear Regulatory Commission. ACTION: Petition for rulemaking; denial...-core thermocouples at different elevations and radial positions throughout the reactor core to enable...

  1. Analysis of heat transfer from fuel rods with externally attached thermocouples

    International Nuclear Information System (INIS)

    Gill, C.R.; Coddington, P.

    1988-05-01

    This paper describes the development of 2 and 3 dimensional finite element heat conduction models to simulate the behaviour of the external thermocouples attached to the LOFT fuel rods during the blowdown phase of a large break loss-of-coolant accident. To establish the model and determine the thermal coupling between the thermocouple and the fuel rod extensive use was made of two series of experiments performed at INEL in the LOFT Test Support Facility (LTSF). These experiments were high pressure reflood experiments with fluid conditions 'typical' of those seen during the bottom-up flow period of the LOFT experiments. (author)

  2. 77 FR 30435 - In-core Thermocouples at Different Elevations and Radial Positions in Reactor Core

    Science.gov (United States)

    2012-05-23

    ... NUCLEAR REGULATORY COMMISSION 10 CFR Part 50 [Docket No. PRM-50-105; NRC-2012-0056] In-core Thermocouples at Different Elevations and Radial Positions in Reactor Core AGENCY: Nuclear Regulatory Commission... of operating licenses for nuclear power plants (``NPP'') to operate NPPs with in-core thermocouples...

  3. Histological-subtypes and anatomical location correlated in meningeal brain tumors (meningiomas

    Directory of Open Access Journals (Sweden)

    Abdul Rashid Bhat

    2014-01-01

    Full Text Available Context: Not enough literature is available to suggest a link between the histological subtypes of intracranial meningeal brain tumors, called ′meningiomas′ and their location of origin. Aim: The evidence of correlation between the anatomical location of the intracranial meningiomas and the histopathological grades will facilitate specific diagnosis and accurate treatment. Materials and Methods: The retrospective study was conducted in a single high-patient-inflow Neurosurgical Center, under a standard and uniform medical protocol, over a period of 30 years from December 1982 to December 2012. The records of all the operated 729 meningiomas were analyzed from the patient files in the Medical Records Department. The biodata, x-rays, angiography, computed tomography (CT scans, imaging, histopathological reports, and mortality were evaluated and results drawn. Results: The uncommon histopathological types of meningiomas (16.88% had common locations of origin in the sphenoid ridge, posterior parafalcine, jugular foramen, peritorcular and intraventricular regions, cerebellopontine angle, and tentorial and petroclival areas. The histopathological World Health Organization (WHO Grade I (Benign Type meningiomas were noted in 89.30%, WHO Grade II (Atypical Type in 5.90%, and WHO Grade III (Malignant Type in 4.80% of all meningiomas. Meningiomas of 64.60% were found in females, 47.32% were in the age group of 41-50 years, and 3.43% meningiomas were found in children. An overall mortality of 6.04% was noted. WHO Grade III (malignant meningiomas carried a high mortality (25.71% and the most common sites of meningiomas with high mortality were: The cerebellopontine angles, intraventricular region, sphenoid ridge, tuberculum sellae, and the posterior parafalcine areas. Conclusion: The correlation between the histological subtypes and the anatomical location of intracranial meningeal brain tumors, called meningiomas, is evident, but further research is

  4. Difference equation approach to two-thermocouple sensor characterization in constant velocity flow environments

    International Nuclear Information System (INIS)

    Hung, P.C.; Irwin, G.; Kee, R.; McLoone, S.

    2005-01-01

    Thermocouples are one of the most popular devices for temperature measurement due to their robustness, ease of manufacture and installation, and low cost. However, when used in certain harsh environments, for example, in combustion systems and engine exhausts, large wire diameters are required, and consequently the measurement bandwidth is reduced. This article discusses a software compensation technique to address the loss of high frequency fluctuations based on measurements from two thermocouples. In particular, a difference equation (DE) approach is proposed and compared with existing methods both in simulation and on experimental test rig data with constant flow velocity. It is found that the DE algorithm, combined with the use of generalized total least squares for parameter identification, provides better performance in terms of time constant estimation without any a priori assumption on the time constant ratios of the thermocouples

  5. Determination of the availability of core exit thermocouples during severe accident situations

    International Nuclear Information System (INIS)

    Edson, J.L.

    1985-04-01

    This report presents the findings and recommendations of the Nuclear Power Plant Instrumentation Evaluation (NPPIE) program concerning signal validation methods to determine the on-line availability of core exit thermocouples during accident situations. Methods of selecting appropriate signal validation techniques are discussed and sources of error identified. This report shows that through the use of these techniques the existence of high-temperature-caused errors may be detected as they occur. Specific recommendations for application of selected signal validation techniques to core exit thermocouples and other measurement systems are made. 23 refs., 22 figs., 3 tabs

  6. Classification of Unknown Thermocouple Types Using Similarity Factor Measurement

    Directory of Open Access Journals (Sweden)

    Seshu K. DAMARLA

    2011-01-01

    Full Text Available In contrast to classification using PCA method, a new methodology is proposed for type identification of unknown thermocouple. The new methodology is based on calculating the degree of similarity between two multivariate datasets using two types of similarity factors. One similarity factor is based on principle component analysis and the angles between the principle component subspaces while the other is based on the Mahalanobis distance between the datasets. Datasets containing thermo-emfs against given temperature ranges are formed for each type of thermocouple (e.g. J, K, S, T, R, E, B and N type by experimentation are considered as reference datasets. Datasets corresponding to unknown type are captured. Similarity factor between the datasets one of which being the unknown type and the other being each known type are compared. When maximum similarity factor occurs, then the class of unknown type is allocated to that of known type.

  7. A novel method for in-situ estimation of time constant for core temperature monitoring thermocouples of operating reactors

    International Nuclear Information System (INIS)

    Sylvia, J.I.; Chandar, S. Clement Ravi; Velusamy, K.

    2014-01-01

    Highlights: • Core temperature sensor was mathematically modeled. • Ramp signal generated during reactor operating condition is used. • Procedure and methodology has been demonstrated by applying it to FBTR. • Same technique will be implemented for all fast reactors. - Abstract: Core temperature monitoring system is an important component of reactor protection system in the current generation fast reactors. In this system, multiple thermocouples are housed inside a thermowell of fuel subassemblies. Response time of the thermocouple assembly forms an important input for safety analysis of fast reactor and hence frequent calibration/time constant estimation is essential. In fast reactors the central fuel subassembly is provided with bare fast response thermocouples to detect under cooling events in reactor and take proper safety action. On the other hand, thermocouples in thermowell are mainly used for blockage detection in individual fuel subassemblies. The time constant of thermocouples in thermowell can drift due to creep, vibration and thermal fatigue of the thermowell assembly. A novel method for in-situ estimation of time constant is proposed. This method uses the Safety Control Rod Accelerated Mechanism (SCRAM) or lowering of control Rod (LOR) signals of the reactor along with response of the central subassembly thermocouples as reference data. Validation of the procedure has been demonstrated by applying it to FBTR

  8. Pulmonary Metastasis from Rectal Cancer on Chest CT Is Correlated with 3T MRI Primary Tumor Location

    International Nuclear Information System (INIS)

    Han, Na Yeon; Kim, Min Ju; Park, Beon Jin; Sung, Deuk Jae; Chung, Kyoo Byung; Oh, Yu Whan

    2011-01-01

    To evaluate the association between the incidence of pulmonary metastasis on chest CT and the location of the primary tumor on rectal MRI. One hundred and nine consecutive patients with rectal adenocarcinoma underwent chest CT and 3T rectal MRI. Two radiologists classified the tumor on MRI as an upper (> 10 cm from the anal verge), mid (5-10 cm), or lower rectal tumor (< 5 cm) by consensus. All chest CT scans were retrospectively reviewed for the presence of metastasis. We used Fisher's exact test to evaluate the correlation between the incidence of pulmonary metastasis with the location of the rectal cancer and the Mantel-Haenszel test to control for local tumor stage. We only included the 60 patients with upper (n = 26) or lower (n = 34) rectal cancer, because of the complicated venous drainage system of the mid rectum. Among these, 9 (15%) showed evidence of pulmonary metastasis on chest CT and almost all (89%, 8/9) patients had lower rectal cancer. The incidence of pulmonary metastasis between the two groups was statistically different (p < 0.05) when local tumor stage was controlled. The incidence of pulmonary metastasis was significantly higher for lower than upper rectal cancers when the T-stage of the tumor was accounted for.

  9. Transcriptional profiles of pilocytic astrocytoma are related to their three different locations, but not to radiological tumor features

    International Nuclear Information System (INIS)

    Zakrzewski, Krzysztof; Jarząb, Michał; Pfeifer, Aleksandra; Oczko-Wojciechowska, Małgorzata; Jarząb, Barbara; Liberski, Paweł P.; Zakrzewska, Magdalena

    2015-01-01

    Pilocytic astrocytoma is the most common type of brain tumor in the pediatric population, with a generally favorable prognosis, although recurrences or leptomeningeal dissemination are sometimes also observed. For tumors originating in the supra-or infratentorial location, a different molecular background was suggested, but plausible correlations between the transcriptional profile and radiological features and/or clinical course are still undefined. The purpose of this study was to identify gene expression profiles related to the most frequent locations of this tumor, subtypes based on various radiological features, and the clinical pattern of the disease. Eighty six children (55 males and 31 females) with histologically verified pilocytic astrocytoma were included in this study. Their age at the time of diagnosis ranged from fourteen months to seventeen years, with a mean age of seven years. There were 40 cerebellar, 23 optic tract/hypothalamic, 21 cerebral hemispheric, and two brainstem tumors. According to the radiological features presented on MRI, all cases were divided into four subtypes: cystic tumor with a non-enhancing cyst wall; cystic tumor with an enhancing cyst wall; solid tumor with central necrosis; and solid or mainly solid tumor. In 81 cases primary surgical resection was the only and curative treatment, and in five cases progression of the disease was observed. In 47 cases the analysis was done by using high density oligonucleotide microarrays (Affymetrix HG-U133 Plus 2.0) with subsequent bioinformatic analyses and confirmation of the results by independent RT-qPCR (on 39 samples). Bioinformatic analyses showed that the gene expression profile of pilocytic astrocytoma is highly dependent on the tumor location. The most prominent differences were noted for IRX2, PAX3, CXCL14, LHX2, SIX6, CNTN1 and SIX1 genes expression even within different compartments of the supratentorial region. Analysis of the genes potentially associated with radiological

  10. Thermocouple module halt failure acceptance test procedure for Tank 241-SY-101 DACS-1

    International Nuclear Information System (INIS)

    Ermi, A.M.

    1997-01-01

    The readiness of the Tank 241-SY-101 Data Acquisition and Control System (DACS-1) to provide monitoring and alarms for a halt failure of any thermocouple module will be tested during the performance of this procedure. Updated DACS-1 ''1/0 MODULE HEALTH STATUS'', ''MININ1'', and ''MININ2'' screens, which now provide indication of thermocouple module failure, will also be tested as part of this procedure

  11. Computerized method for estimation of the location of a lung tumor on EPID cine images without implanted markers in stereotactic body radiotherapy

    International Nuclear Information System (INIS)

    Arimura, H; Toyofuku, F; Higashida, Y; Onizuka, Y; Terashima, H; Egashira, Y; Shioyama, Y; Nomoto, S; Honda, H; Nakamura, K; Yoshidome, S; Anai, S

    2009-01-01

    The purpose of this study was to develop a computerized method for estimation of the location of a lung tumor in cine images on an electronic portal imaging device (EPID) without implanted markers during stereotactic body radiotherapy (SBRT). Each tumor region was segmented in the first EPID cine image, i.e., reference portal image, based on a multiple-gray level thresholding technique and a region growing technique, and then the image including the tumor region was cropped as a 'tumor template' image. The tumor location was determined as the position in which the tumor template image took the maximum cross-correlation value within each consecutive portal image, which was acquired in cine mode on the EPID in treatment. EPID images with 512 x 384 pixels (pixel size: 0.56 mm) were acquired at a sampling rate of 0.5 frame s -1 by using energies of 4, 6 or 10 MV on linear accelerators. We applied our proposed method to EPID cine images (226 frames) of 12 clinical cases (ages: 51-83, mean: 72) with a non-small cell lung cancer. As a result, the average location error between tumor points obtained by our method and the manual method was 1.47 ± 0.60 mm. This preliminary study suggests that our method based on the tumor template matching technique might be feasible for tracking the location of a lung tumor without implanted markers in SBRT.

  12. Evaluation of RTD and thermocouple for PID temperature control in ...

    African Journals Online (AJOL)

    Evaluation of RTD and thermocouple for PID temperature control in distributed control system laboratory. D. A. A. Nazarudin, M. K. Nordin, A. Ahmad, M. Masrie, M. F. Saaid, N. M. Thamrin, M. S. A. M. Ali ...

  13. Diffuse high-grade gliomas with H3 K27M mutations carry a dismal prognosis independent of tumor location.

    Science.gov (United States)

    Karremann, Michael; Gielen, Gerrit H; Hoffmann, Marion; Wiese, Maria; Colditz, Niclas; Warmuth-Metz, Monika; Bison, Brigitte; Claviez, Alexander; van Vuurden, Dannis G; von Bueren, André O; Gessi, Marco; Kühnle, Ingrid; Hans, Volkmar H; Benesch, Martin; Sturm, Dominik; Kortmann, Rolf-Dieter; Waha, Andreas; Pietsch, Torsten; Kramm, Christof M

    2018-01-10

    The novel entity of "diffuse midline glioma, H3 K27M-mutant" has been defined in the 2016 revision of the World Health Organization (WHO) classification of tumors of the central nervous system (CNS). Tumors of this entity arise in CNS midline structures of predominantly pediatric patients and are associated with an overall dismal prognosis. They are defined by K27M mutations in H3F3A or HIST1H3B/C, encoding for histone 3 variants H3.3 and H3.1, respectively, which are considered hallmark events driving gliomagenesis. Here, we characterized 85 centrally reviewed diffuse gliomas on midline locations enrolled in the nationwide pediatric German HIT-HGG registry regarding tumor site, histone 3 mutational status, WHO grade, age, sex, and extent of tumor resection. We found 56 H3.3 K27M-mutant tumors (66%), 6 H3.1 K27M-mutant tumors (7%), and 23 H3-wildtype tumors (27%). H3 K27M-mutant gliomas shared an aggressive clinical course independent of their anatomic location. Multivariate regression analysis confirmed the significant impact of the H3 K27M mutation as the only independent parameter predictive of overall survival (P = 0.009). In H3 K27M-mutant tumors, neither anatomic midline location nor histopathological grading nor extent of tumor resection had an influence on survival. These results substantiate the clinical significance of considering diffuse midline glioma, H3 K27M-mutant, as a distinct entity corresponding to WHO grade IV, carrying a universally fatal prognosis. © The Author(s) 2017. Published by Oxford University Press on behalf of the Society for Neuro-Oncology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  14. Development of thermocouple re-instrumentation technique for irradiated fuel rod. Techniques for making center hole into UO2 pellets and thermocouple re-instrumentation to fuel rod

    International Nuclear Information System (INIS)

    Shimizu, Michio; Saito, Junichi; Oshima, Kunio

    1995-07-01

    The information on FP gas pressure and centerline temperature of fuel pellets during power transient is important to study the pellet clad interaction (PCI) mechanism of high burnup LWR fuel rods. At the Department of JMTR, a re-instrumentation technique of FP gas pressure gage for an irradiated fuel rod was developed in 1990. Furthermore, a thermocouple re-instrumentation technique was successfully developed in 1994. Two steps were taken to carry out the development program of the thermocouple re-instrumentation technique. In the first step, a drilling technique was developed for making a center hole of the irradiated fuel pellets. Various drilling tests were carried out using dummy of fuel rods consisted of Ba 2 FeO 3 pellets and Zry-2 cladding. On this work it is important to keep the pellets just the state cracked at a power reactor. In these tests, the technique to fix the pellets by frozen CO 2 was used during the drilling work. Also, diamond drills were used to make the center hole. These tests were completed successfully. A center hole, 54mm depth and 2.5mm diameter, was realized by these methods. The second step of this program is the in-pile demonstration test on an irradiated fuel rod instrumented dually a thermocouple and FP gas pressure gage. The demonstration test was carried out at the JMTR in 1995. (author)

  15. SU-E-J-107: The Impact of the Tumor Location to Deformable Image Registration

    International Nuclear Information System (INIS)

    Sugawara, Y; Tachibana, H; Kadoya, N; Jingu, K; Kitamura, N

    2015-01-01

    Purpose: For four-dimensional planning and adaptive radiotherapy, the accuracy of deformable image registration (DIR) is essential. We evaluated the accuracy of an in-house program with the free-downloadable DIR software library package (NiftyReg) and two commercially available DIR software programs (MIM Maestro and Velocity AI) in lung SBRT cancer patients. In addition to it, the relationship between the tumor location and the accuracy of the DIRs was investigated. Methods: The free-form deformation was implemented in the in-house program and the MIM. The Velocity was based on the B-spline algorithm. The accuracy of the three programs was evaluated in comparison for the structures on 4DCT image datasets between at the peak-inhale and at the peak-exhale. The dice similarity coefficient (DSC) and normalized DSC (NDSC) were measured for the gross tumor volumes from 19 lung SBRT patients. Results: The DSC measurement showed the median values of the DSC were 0.885, 0.872 and 0.798 for the In-house program, the MIM and the Velocity, respectively. The Velocity showed significant difference compared to the others. The median NDSC values were 1.027, 1.005 and 0.946 for the In-house, the MIM and the Velocity, respectively. This indicated that the spatial overlap agreement between the reference and the deformed structure for the in-house and MIM was comparable with the accuracy within 1mm uncertainty. There was larger discrepancy within 1–2mm uncertainty for the Velocity. The In-house and the MIM showed the higher NDSC values than the median values when the GTV was not attached to the chest wall and diaphragm(p < 0.05). However, there is no relationship between the accuracy and the tumor location in the Velocity. Conclusion: The difference of the DIR program would affect different accuracy and the accuracy may be reduced when the tumor is located or attached to chest wall or diaphragm

  16. Relocation work of temporary thermocouples for measuring the vessel cooling system in the safety demonstration test

    International Nuclear Information System (INIS)

    Shimazaki, Yosuke; Shinohara, Masanori; Ono, Masato; Yanagi, Shunki; Tochio, Daisuke; Iigaki, Kazuhiko

    2012-05-01

    It is necessary to confirm that the temperature of water cooling panel of the vessel cooling system (VCS) is controlled under the allowable working temperature during the safety demonstration test because the water cooling panel temperature rises due to stop of cooling water circulation pumps. Therefore, several temporary thermocouples are relocated to the water cooling panel near the stabilizers of RPV and the side cooling panel outlet ring header of VCS in order to observe the temperature change of VCS. The relocated thermocouples can measure the temperature change with starting of the cooling water circulation pumps of VCS. So it is confirmed that the relocated thermocouples can observe the VCS temperature change in the safety demonstration test. (author)

  17. Accuracy of small diameter sheathed thermocouples for the core flow test loop

    International Nuclear Information System (INIS)

    Anderson, R.L.; Kollie, T.G.

    1979-04-01

    This report summarizes the research and development on 0.5-mm-diameter, compacted, metal sheathed thermocouples. The objectives of this research effort have been: to identify and analyze the sources of temperature measurement errors in the use of 0.5-mm-diameter sheathed thermocouples to measure the surface temperature of the cladding of fuel-rod simulators in the Core Flow Test Loop (CFTL) at ORNL; to devise methods for reducing or correcting for these temperature measurement errors; to estimate the overall temperature measurement uncertainties; and to recommend modifications in the manufacture, installation, or materials used to minimize temperature measurement uncertainties in the CFTL experiments

  18. Association between mutations of critical pathway genes and survival outcomes according to the tumor location in colorectal cancer.

    Science.gov (United States)

    Lee, Dae-Won; Han, Sae-Won; Cha, Yongjun; Bae, Jeong Mo; Kim, Hwang-Phill; Lyu, Jaemyun; Han, Hyojun; Kim, Hyoki; Jang, Hoon; Bang, Duhee; Huh, Iksoo; Park, Taesung; Won, Jae-Kyung; Jeong, Seung-Yong; Park, Kyu Joo; Kang, Gyeong Hoon; Kim, Tae-You

    2017-09-15

    Colorectal cancer (CRC) develops through the alteration of several critical pathways. This study was aimed at evaluating the influence of critical pathways on survival outcomes for patients with CRC. Targeted next-generation sequencing of 40 genes included in the 5 critical pathways of CRC (WNT, P53, RTK-RAS, phosphatidylinositol-4,5-bisphosphate 3-kinase [PI3K], and transforming growth factor β [TGF-β]) was performed for 516 patients with stage III or high-risk stage II CRC treated with surgery followed by adjuvant fluoropyrimidine and oxaliplatin chemotherapy. The associations between critical pathway mutations and relapse-free survival (RFS) and overall survival were analyzed. The associations were further analyzed according to the tumor location. The mutation rates for the WNT, P53, RTK-RAS, PI3K, and TGF-β pathways were 84.5%, 69.0%, 60.7%, 30.0%, and 28.9%, respectively. A mutation in the PI3K pathway was associated with longer RFS (adjusted hazard ratio [HR], 0.59; 95% confidence interval [CI], 0.36-0.99), whereas a mutation in the RTK-RAS pathway was associated with shorter RFS (adjusted HR, 1.60; 95% CI, 1.01-2.52). Proximal tumors showed a higher mutation rate than distal tumors, and the mutation profile was different according to the tumor location. The mutation rates of Kirsten rat sarcoma viral oncogene homolog (KRAS), phosphatidylinositol-4,5-bisphosphate 3-kinase catalytic subunit α (PIK3CA), and B-Raf proto-oncogene serine/threonine kinase (BRAF) were higher in proximal tumors, and the mutation rates of adenomatous polyposis coli (APC), tumor protein 53 (TP53), and neuroblastoma RAS viral oncogene homolog (NRAS) were higher in distal tumors. The better RFS with the PI3K pathway mutation was significant only for proximal tumors, and the worse RFS with the RTK-RAS pathway mutation was significant only for distal tumors. A PI3K pathway mutation was associated with better RFS for CRC patients treated with adjuvant chemotherapy, and an RTK

  19. Novel thermocouples for automotive applications

    Directory of Open Access Journals (Sweden)

    P. Gierth

    2018-02-01

    Full Text Available Measurement of temperatures in engine and exhaust systems in automotive applications is necessary for thermal protection of the parts and optimizing of the combustion process. State-of-the-art temperature sensors are very limited in their response characteristic and installation space requirement. Miniaturized sensor concepts with a customizable geometry are needed. The basic idea of this novel sensor concept is to use thick-film technology on component surfaces. Different standardized and especially nonstandard material combinations of thermocouples have been produced for the validation of this technology concept. Application-oriented measurements took place in the exhaust system of a test vehicle and were compared to standard laboratory conditions.

  20. CT and MRI of germ-cell tumors with metastasis or multi-located tumors

    International Nuclear Information System (INIS)

    Miyagami, Mitsusuke; Tazoe, Makoto; Tsubokawa, Takashi

    1989-01-01

    Twenty-seven cases of germ-cell tumors were examined with a CT scan in our clinic. In the 11 cases of metastasis or multi-localized tumors, the CT findings were studied in connection with the MRI findings. There were 6 cases of germ-cell tumors which had broad infiltrating tumors with multiple lesions on first admission. Their tumor sites were different from that in cases of malignant glioma, being frequently localized in the pineal and/or the suprasellar region, on the wall of the third and/or lateral ventricle, and in the region of the basal ganglia. Five of the cases of germ-cell tumors had metastasis with various patterns connected to a remote area - that is, to spinal cords, to the ventricular wall and basal cistern of the brain stem by CSF dissemination, to a lung by hematogeneous metastasis, and to the peritoneal wall or organs by a V-P shunt. The CT findings of germ-cell tumors were correlated mainly with the results of the histological diagnosis; they were found not to differ with the tumor site. The germinoma in the suprasellar region had less calcification than in the pineal region. Cysts, calcification, and an enlargement of the lateral ventricle on the tumor side were frequently seen in the germinoma of the basal ganglia. On the MRI of 5 cases of germinoma, the T 1 -weighted image revealed a slightly low or iso signal intensity, while the T 2 -weighted image showed a high signal intensity. In the case of multiple tumor lesions, some cases demonstrated different CT findings and radiosensitivities for each tumor. The possibility of a multicentric origin for the tumors is thus suggested in some cases of germ-cell tumors. (author)

  1. Proton radiation therapy for retinoblastoma: Comparison of various intraocular tumor locations and beam arrangements

    International Nuclear Information System (INIS)

    Krengli, Marco; Hug, Eugen B.; Adams, Judy A.; Smith, Alfred R.; Tarbell, Nancy J.; Munzenrider, John E.

    2005-01-01

    Purpose: To study the optimization of proton beam arrangements for various intraocular tumor locations; and to correlate isodose distributions with various target and nontarget structures. Methods and materials: We considered posterior-central, nasal, and temporal tumor locations, with straight, intrarotated, or extrarotated eye positions. Doses of 46 cobalt grey equivalent (CGE) to gross tumor volume (GTV) and 40 CGE to clinical target volume (CTV) (2 CGE per fraction) were assumed. Using three-dimensional planning, we compared isodose distributions for lateral, anterolateral oblique, and anteromedial oblique beams and dose-volume histograms of CTVs, GTVs, lens, lacrimal gland, bony orbit, and soft tissues. Results: All beam arrangements fully covered GTVs and CTVs with optimal lens sparing. Only 15% of orbital bone received doses ≥20 CGE with a lateral beam, with 20-26 CGE delivered to two of three growth centers. The anterolateral oblique approach with an intrarotated eye resulted in additional reduction of bony volume and exposure of only one growth center. No appreciable dose was delivered to the contralateral eye, brain tissue, or pituitary gland. Conclusions: Proton therapy achieved homogeneous target coverage with true lens sparing. Doses to orbit structures, including bony growth centers, were minimized with different beam arrangements and eye positions. Proton therapy could reduce the risks of second malignancy and cosmetic and functional sequelae

  2. Flow measurements using noise signals of axially displaced thermocouples

    Energy Technology Data Exchange (ETDEWEB)

    Kozma, R.; Hoogenboom, J.E. (Interuniversitair Reactor Inst., Delft (Netherlands))

    1990-01-01

    Determination of the flow rate of the coolant in the cooling channels of nuclear reactors is an important aspect of core monitoring. It is usually impossible to measure the flow by flowmeters in the individual channels due to the lack of space and safety reasons. An alternative method is based on the analysis of noise signals of the available in-core detectors. In such a noise method, a transit time which characterises the propagation of thermohydraulic fluctuations (density or temperature fluctuations) in the coolant is determined from the correlation between the noise signals of axially displaced detectors. In this paper, the results of flow measurements using axially displaced thermocouples in the channel wall will be presented. The experiments have been performed in a simulated MRT-type fuel assembly located in the research reactor HOR of the Interfaculty Reactor Institute, Delft. It was found that the velocities obtained via temperature noise correlation methods are significantly larger than the area-averaged velocity in the single-phase coolant flow. Model calculations show that the observed phenomenon can be explained by effects due to the radial velocity distribution in the channel. (author).

  3. Dosimetric investigation depending on tumor location in patient breast in partial breast irradiation

    International Nuclear Information System (INIS)

    Kim, Min Joo; Park, So Hyun; Jung, Joo Young; Woong, Cho; Suh, Tae Suk

    2012-01-01

    The Partial Breast Irradiation (PBI) technique, which involves radiation beam delivery techniques that use a limited range of treatment volumes, has been a challenging approach that is worthy of consideration compared to whole-breast radiation therapy (WBRT). Because of a small target volumes used in the PBI technique, the radiation dose can be safely delivered to the targeted tissue without the unwanted delivery of radiation to normal breast tissues and organ at risk (OAR), such as contralateral breast, lung and heart.Through PBI technique, better cosmetic outcomes and minimizing damages to OARs could be expected and also the daily dose can be increased with smaller number of fractionation in radiation therapy. The purpose of this study was to evaluate the dosimetric effects according to tumor locations in patient's breast for Partial Breast Irradiation (PBI) technique using three Dimensional Conformal Radiation Therapy (3DCRT), Electron Beam Radiation therapy (EBRT) and Helical-tomotherapy (H-TOMO). Dosimetric comparisons of PBI technique for 3DCRT, EBRT, and H-TOMO depending on the classified tumor locations were performed. H-TOMO delivered the low dose to lager volume to surrounding normal tissue, such as the heart and lungs compared to 3DCRT and EBRT although it had the same degree of target coverage as the other methods (3DCRT, EBRT). EBRT had a curative effect for early-stage breast cancers located in the lower and inner sections (LIQ-S, LIQ-D)

  4. Experience from replacement and check of thermocouples during reconstruction of in-reactor temperature measurements at Bohunice V-1 units 1 and 2

    International Nuclear Information System (INIS)

    Slanina, M.; Stanc, J.

    2001-01-01

    Replacement of thermocouples in the protection tube blocks was a key phase of the reconstruction of in-reactor temperature measurements at Bohunice V-1 with regard to the success, reliability and impact on safety of unit operation. The replacement consisted of reliable and safe withdrawal of 216 old thermocouples, their disposal and installation of new thermocouples into dry channels. In the material presented, this phase of reconstruction is described in details, with focus on the evaluation of replacement quality and check activities carried out at the new installed thermocouples. (Authors)

  5. Temperature Control System for Chromel-Alumel Thermocouple

    International Nuclear Information System (INIS)

    Piping Supriatna; Nurhanan; Riswan DJ; Heru K, B.; Edi Karyanta

    2003-01-01

    Nuclear Power Plan Operation Safety needs serious handling on temperature measurement and control. In this report has been done manufacturing Temperature Control System for Chromel-Alumel Thermocouple, accordance to material, equipment and human resource ability in the laboratory. Basic component for the Temperature Control System is LM-741 type of Operation Amplifier, which is functionalized as summer for voltage comparator. Function test for this Control System shown its ability for damping on temperature reference. The Temperature Control System will be implemented on PCB Processing Machine. (author)

  6. A Highly Thermostable In2O3/ITO Thin Film Thermocouple Prepared via Screen Printing for High Temperature Measurements

    Directory of Open Access Journals (Sweden)

    Yantao Liu

    2018-03-01

    Full Text Available An In2O3/ITO thin film thermocouple was prepared via screen printing. Glass additives were added to improve the sintering process and to increase the density of the In2O3/ITO films. The surface and cross-sectional images indicate that both the grain size and densification of the ITO and In2O3 films increased with the increase in annealing time. The thermoelectric voltage of the In2O3/ITO thermocouple was 53.5 mV at 1270 °C at the hot junction. The average Seebeck coefficient of the thermocouple was calculated as 44.5 μV/°C. The drift rate of the In2O3/ITO thermocouple was 5.44 °C/h at a measuring time of 10 h at 1270 °C.

  7. Improvement in the technology of thermocouples for the detection of high temperatures with a view to using them in irradiation safety tests in reactor

    International Nuclear Information System (INIS)

    Schley, R.; Liermann, J.; Aujollet, J.M.; Wilkins, S.C.

    1979-01-01

    The safety tests carried out under the CABRI and PHEBUS programmes have made it possible to improve the technology of W/Re thermocouples and their reliability in particularly hard operating conditions. An element of response is provided to the problem of W/Re thermocouple drift under neutron flux by defining the new thermocouple Mo 5% Nb/Nb 10% Mo which, because of the low capture cross section of thermoelectric elements, gives one reason to hope for a less significant drift of these thermocouples under neutron flux than that found with W/Re thermocouples. Finally, determining the surface temperature of fuel element cladding with the Mo/Zircaloy thermocouple may prove worthwhile providing the temperatures do not exceed 1300 0 C and the electric insulator is aluminium oxide which up to 1300 0 C does not appear to react with thermoelectric wires [fr

  8. Prognostic Impact of Primary Tumor Location on Clinical Outcomes of Metastatic Colorectal Cancer Treated With Cetuximab Plus Oxaliplatin-Based Chemotherapy: A Subgroup Analysis of the JACCRO CC-05/06 Trials.

    Science.gov (United States)

    Sunakawa, Yu; Ichikawa, Wataru; Tsuji, Akihito; Denda, Tadamichi; Segawa, Yoshihiko; Negoro, Yuji; Shimada, Ken; Kochi, Mitsugu; Nakamura, Masato; Kotaka, Masahito; Tanioka, Hiroaki; Takagane, Akinori; Tani, Satoshi; Yamaguchi, Tatsuro; Watanabe, Takanori; Takeuchi, Masahiro; Fujii, Masashi; Nakajima, Toshifusa

    2017-09-01

    Primary tumor location is a critical prognostic factor in metastatic colorectal cancer (mCRC); however, it remains unclear whether tumor location is a predictor of the response to cetuximab treatment. It is also uncertain if BRAF mutation contributes to the impact of tumor location on survival. We assessed the prognostic impact of tumor location on clinical outcomes in mCRC patients treated with first-line cetuximab chemotherapy. The associations of tumor location with overall survival and progression-free survival were evaluated in mCRC patients with KRAS exon 2 wild-type tumors who were enrolled onto 2 clinical trials: JACCRO CC-05 of cetuximab plus FOLFOX (n = 57, UMIN000004197) and CC-06 of cetuximab plus SOX (n = 61, UMIN000007022). Tumors proximal or from splenic flexure to rectum were defined as right-sided or left-sided, respectively. In addition, exploratory RAS and BRAF mutation analyses were performed. A total of 110 patients were assessable for tumor location; 90 had left-sided tumors. Left-sided tumors were significantly associated with longer overall survival (36.2 vs. 12.6 months, hazard ratio = 0.28, P location was an independent prognostic factor irrespective of BRAF status in RAS wild-type patients. Primary tumor location might be a predictor of survival independent of BRAF status in mCRC patients who receive first-line cetuximab combined with oxaliplatin-based chemotherapy. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Relationship between apathy and tumor location, size, and brain edema in patients with intracranial meningioma

    Directory of Open Access Journals (Sweden)

    Peng Y

    2015-07-01

    Full Text Available Yihua Peng,1,* Chunhong Shao,1,* Ye Gong,2 Xuehai Wu,2 Weijun Tang,3 Shenxun Shi1 1Psychiatry Department, 2Neurosurgery Department, 3Radiology Department, Huashan Hospital, Fudan University, People’s Republic of China *These authors contributed equally to this work Background: The purpose of this study is to assess the relationship between apathy and tumor location, size, and brain edema in patients with intracranial meningioma. Methods: We enrolled 65 consecutive patients with meningioma and 31 normal controls matched for age, gender, and education. The patients were divided into frontal or non-frontal (NF meningioma groups based on magnetic resonance imaging; the frontal group was then subdivided to dorsolateral frontal (DLF, medial frontal (MF, and ventral frontal (VF groups. Tumor size and brain edema were also recorded. Apathy was assessed by the Apathy Evaluation Scale (AES. Assessments were carried out 1 week before and 3 months after surgery, respectively. Logistic regression analysis was performed to identify the predictive effect of tumor size, location, and brain edema on apathy. Analysis of variance and chi-square analysis were applied to compare apathy scores and apathy rates among the frontal, NF, and normal control groups, and all subgroups within the frontal group. Results: Compared with the NF and control groups, the mean AES score was much higher in the frontal group (34.0±8.3 versus 28.63±6.0, P=0.008, and 26.8±4.2, P<0.001. Subgroup analysis showed that AES scores in the MF group (42.1±6.6 and VF group (34.7±8.0 were higher than in the DLF group (28.5±4.36, NF group, and control group (P<0.05. The apathy rate was 63.6% in the MF group and 25% in the VF group, and significantly higher than in the DLF (5.6%, NF (5.3%, and control (0% groups (P<0.001. A moderate correlation was found between AES score and mean diameter of the meningioma in all patient groups. Further analysis demonstrated that the correlation existed in

  10. Experiences with W3Re/W25Re thermocouples in fuel pins of NS Otto Hahn's two cores

    International Nuclear Information System (INIS)

    Kolb, M.

    1975-01-01

    Applications and performance of thermocouples in the Otto Hahn reactor are presented. The measurement of effective thermocouple time constants and of fuel rod heat transfer time constants utilizing the reactor noise and the resulting small temperature fluctuations which has become practical by the advent of modern noise analysis systems, is dealt with

  11. Recent improvements on micro-thermocouple based SThM

    OpenAIRE

    Nguyen, T. P.; Thiery, L.; Teyssieux, D.; Briand, Danick; Vairac, P.

    2017-01-01

    The scanning thermal microscope (SThM) has become a versatile tool for local surface temperature mapping or measuring thermal properties of solid materials. In this article, we present recent improvements in a SThM system, based on a micro-wire thermocouple probe associated with a quartz tuning fork for contact strength detection. Some results obtained on an electrothermal micro-hotplate device, operated in active and passive modes, allow demonstrating its performance as a coupled force detec...

  12. The influence of lead temperature on the accuracy of various stainless-steel sheathed, mineral-inulated nickel-chromium/nickel aluminium thermocouples

    International Nuclear Information System (INIS)

    Burnett, P.; Burns, J.S.

    1977-10-01

    Samples of three types of stainless steel sheathed MI thermocouples, such as are currently used in fire and furnace tests of transport flasks, have been subjected to high lead temperatures whilst the thermojunctions were kept at a constant low temperature. Both the lead temperature and the length of lead at temperature have been varied. As the lead temperature rises from ambient to a selected value, the emf output from the thermocouple initially decreases and then increases, taking up a final value dependent on the particular conditions. Below a threshold lead temperature, no significant steady state error occurs and the negative transient is generally negligible. Each thermocouple has its own threshold temperature, the lowest found being about 600 0 C, although the average lies at about 750 0 C. Above the threshold lead temperature, the thermal emf can be in error by the equivalent of more than 100 0 C, the highest error found being nearly 230 0 C at a temperature 250 0 C above threshold. The same thermocouple showed a negative transient of 13 0 C 3 minutes after start of heating to 890 0 C. It is probable that the steady state error arises because of the degradation of the thermocouple mineral insulation at elevated temperatures and recommendations are made on the use of such thermocouples in fire and furnace tests. The cause of the initial negative transient error has not been identified, but ways of minimising any resultant errors are suggested. (author)

  13. Heated junction thermocouple level measurement apparatus

    International Nuclear Information System (INIS)

    Bevilacqua, F.; Burger, J.M.

    1984-01-01

    A liquid level sensing apparatus senses the level of liquid surrounding the apparatus. A plurality of axially spaced sensors are enclosed in a separator tube. The separator tube tends to collapse the level of a two-phase fluid within the separator tube into essentially a liquid phase and a gaseous phase where the collapsed level bears a relationship to the coolant inventory outside the separator tube. The level of the liquid phase is sensed by level sensing apparatus. The separator tube contains inlet-outlet ports near the top and bottom thereof to equalize the liquid level inside and outside the separator tube when the level fluctuates or the water within the separator tube flashes to steam. Each sensor is comprised of a heater, a heated thermocouple junction and an unheated thermocouple junction within an elongated heat conductive housing. The heated portion of housing is enclosed in a splash guard with inlet-outlet ports near the top and bottom to equalize the liquid level inside and outside the splash guardand to eliminate the spurious indications of liquid level change which may arise if water droplets contact the housing in the region of the heater. To prevent steam bubbles entrained in a two-phase fluid cross flow from entering the lateral inlet-outlet ports of the separator tube, the separator tube is enclosed in support tube which may in turn be enclosed in an otherwise unused control element assembly shroud. The lateral inlet-outlet ports of separator tube are axially offset from lateral inlet-outlet ports of support tube at least where support tube is subjected to cross flow. The shroud is open on the bottom and has lateral inlet-outlet ports to facilitate liquid level fluctuations to equalize inside and outside shroud

  14. Proposed algorithm for determining the delta intercept of a thermocouple psychrometer curve

    International Nuclear Information System (INIS)

    Kurzmack, M.A.

    1993-01-01

    The USGS Hydrologic Investigations Program is currently developing instrumentation to study the unsaturated zone at Yucca Mountain in Nevada. Surface-based boreholes up to 2,500 feet in depth will be drilled, and then instrumented in order to define the water potential field within the unsaturated zone. Thermocouple psychrometers will be used to monitor the in-situ water potential. An algorithm is proposed for simply and efficiently reducing a six wire thermocouple psychrometer voltage output curve to a single value, the delta intercept. The algorithm identifies a plateau region in the psychrometer curve and extrapolates a linear regression back to the initial start of relaxation. When properly conditioned for the measurements being made, the algorithm results in reasonable results even with incomplete or noisy psychrometer curves over a 1 to 60 bar range

  15. 4π Noncoplanar Stereotactic Body Radiation Therapy for Centrally Located or Larger Lung Tumors

    International Nuclear Information System (INIS)

    Dong, Peng; Lee, Percy; Ruan, Dan; Long, Troy; Romeijn, Edwin; Low, Daniel A.; Kupelian, Patrick; Abraham, John; Yang, Yingli; Sheng, Ke

    2013-01-01

    Purpose: To investigate the dosimetric improvements in stereotactic body radiation therapy for patients with larger or central lung tumors using a highly noncoplanar 4π planning system. Methods and Materials: This study involved 12 patients with centrally located or larger lung tumors previously treated with 7- to 9-field static beam intensity modulated radiation therapy to 50 Gy. They were replanned using volumetric modulated arc therapy and 4π plans, in which a column generation method was used to optimize the beam orientation and the fluence map. Maximum doses to the heart, esophagus, trachea/bronchus, and spinal cord, as well as the 50% isodose volume, the lung volumes receiving 20, 10, and 5 Gy were minimized and compared against the clinical plans. A dose escalation study was performed to determine whether a higher prescription dose to the tumor would be achievable using 4π without violating dose limits set by the clinical plans. The deliverability of 4π plans was preliminarily tested. Results: Using 4π plans, the maximum heart, esophagus, trachea, bronchus and spinal cord doses were reduced by 32%, 72%, 37%, 44%, and 53% (P≤.001), respectively, and R 50 was reduced by more than 50%. Lung V 20 , V 10 , and V 5 were reduced by 64%, 53%, and 32% (P≤.001), respectively. The improved sparing of organs at risk was achieved while also improving planning target volume (PTV) coverage. The minimal PTV doses were increased by the 4π plans by 12% (P=.002). Consequently, escalated PTV doses of 68 to 70 Gy were achieved in all patients. Conclusions: We have shown that there is a large potential for plan quality improvement and dose escalation for patients with larger or centrally located lung tumors using noncoplanar beams with sufficient quality and quantity. Compared against the clinical volumetric modulated arc therapy and static intensity modulated radiation therapy plans, the 4π plans yielded significantly and consistently improved tumor coverage and

  16. 4π Noncoplanar Stereotactic Body Radiation Therapy for Centrally Located or Larger Lung Tumors

    Energy Technology Data Exchange (ETDEWEB)

    Dong, Peng; Lee, Percy; Ruan, Dan [Department of Radiation Oncology, University of California Los Angeles, Los Angeles, California (United States); Long, Troy; Romeijn, Edwin [Department of Industrial and Operations Engineering, University of Michigan, Ann Arbor, Michigan (United States); Low, Daniel A.; Kupelian, Patrick; Abraham, John; Yang, Yingli [Department of Radiation Oncology, University of California Los Angeles, Los Angeles, California (United States); Sheng, Ke, E-mail: ksheng@mednet.ucla.edu [Department of Radiation Oncology, University of California Los Angeles, Los Angeles, California (United States)

    2013-07-01

    Purpose: To investigate the dosimetric improvements in stereotactic body radiation therapy for patients with larger or central lung tumors using a highly noncoplanar 4π planning system. Methods and Materials: This study involved 12 patients with centrally located or larger lung tumors previously treated with 7- to 9-field static beam intensity modulated radiation therapy to 50 Gy. They were replanned using volumetric modulated arc therapy and 4π plans, in which a column generation method was used to optimize the beam orientation and the fluence map. Maximum doses to the heart, esophagus, trachea/bronchus, and spinal cord, as well as the 50% isodose volume, the lung volumes receiving 20, 10, and 5 Gy were minimized and compared against the clinical plans. A dose escalation study was performed to determine whether a higher prescription dose to the tumor would be achievable using 4π without violating dose limits set by the clinical plans. The deliverability of 4π plans was preliminarily tested. Results: Using 4π plans, the maximum heart, esophagus, trachea, bronchus and spinal cord doses were reduced by 32%, 72%, 37%, 44%, and 53% (P≤.001), respectively, and R{sub 50} was reduced by more than 50%. Lung V{sub 20}, V{sub 10}, and V{sub 5} were reduced by 64%, 53%, and 32% (P≤.001), respectively. The improved sparing of organs at risk was achieved while also improving planning target volume (PTV) coverage. The minimal PTV doses were increased by the 4π plans by 12% (P=.002). Consequently, escalated PTV doses of 68 to 70 Gy were achieved in all patients. Conclusions: We have shown that there is a large potential for plan quality improvement and dose escalation for patients with larger or centrally located lung tumors using noncoplanar beams with sufficient quality and quantity. Compared against the clinical volumetric modulated arc therapy and static intensity modulated radiation therapy plans, the 4π plans yielded significantly and consistently improved tumor

  17. Recent improvements on micro-thermocouple based SThM

    Science.gov (United States)

    Nguyen, TP; Thiery, L.; Teyssieux, D.; Briand, D.; Vairac, P.

    2017-01-01

    The scanning thermal microscope (SThM) has become a versatile tool for local surface temperature mapping or measuring thermal properties of solid materials. In this article, we present recent improvements in a SThM system, based on a micro-wire thermocouple probe associated with a quartz tuning fork for contact strength detection. Some results obtained on an electrothermal micro-hotplate device, operated in active and passive modes, allow demonstrating its performance as a coupled force detection and thermal measurement system.

  18. R and D advances in high temperature thermocouples for nuclear utilization in severe environment

    International Nuclear Information System (INIS)

    Schley, R.; Blanc, J.Y.

    1985-01-01

    Safety experiments for water reactors in Cadarache have made necessary a research program for developing special thermocopules for use in severe fuel damage conditions (superheated steam). Standard cladding thermocouples (type K, alumina insulated, zircaloy sheathed, O.D. 0.7 mm) must be replaced by others with W3Re versus W25Re legs, Ta sheath protected by a zircaloy outer sheath, and hafnia or thoria insulation. The zircaloy sheath will be sufficient to protect correctly tantalum. Fuel centerline thermocouples have W5Re versus W26Re or W3Re versus W25Re legs, hard-fired thoria insulation and rhenium CVD sheath (O.D. 1.1 mm). A protective ReSi/sub 2/ coating is applied. This protection withstands at least 1600 0 C, 45 minutes in steam. Tests are done concerning: (a) materials compatibilities in helium between 1400 0 C and 2000 0 C, (b) prototypes qualification (In Saclay or Grenoble), (c) determination of errors due to degradation of insulation resistance of thermocouples cables (with magnesia, hafnia, alumina), (d) Ir or Re protective coatings by CVD process, other coatings by ionic bombardment, etc...A completely new type of hot junction has been patented

  19. Thermocouple placement and hot spots in radioactive waste tanks

    International Nuclear Information System (INIS)

    Barker, J.J.

    1991-06-01

    Analytical solutions available in Carslaw and Jaeger's Conduction of Heat in Solids for continuous point sources and for continuous finite sources are used to demonstrate that placement of thermocouples on a fine enough grid to detect a hot spot is impracticable for existing waste tanks but fortunately not necessary. Graphs covering ranges of diffusivities, times, temperatures and heat generation rates are included. 2 refs., 8 figs., 5 tabs

  20. Attachment of Free Filament Thermocouples for Temperature Measurements on Ceramic Matrix Composites

    Science.gov (United States)

    Lei, Jih-Fen; Cuy, Michael D.; Wnuk, Stephen P.

    1998-01-01

    At the NASA Lewis Research Center, a new installation technique utilizing convoluted wire thermocouples (TC's) was developed and proven to produce very good adhesion on CMC's, even in a burner rig environment. Because of their unique convoluted design, such TC's of various types and sizes adhere to flat or curved CMC specimens with no sign of delamination, open circuits, or interactions-even after testing in a Mach 0.3 burner rig to 1200 C (2200 F) for several thermal cycles and at several hours at high temperatures. Large differences in thermal expansion between metal thermocouples and low-expansion materials, such as CMC's, normally generate large stresses in the wires. These stresses cause straight wires to detach, but convoluted wires that are bonded with strips of coating allow bending in the unbonded portion to relieve these expansion stresses.

  1. Thermocouples used in emission systems of internal combustion engines; Thermoelemente fuer den Einsatz in Abgassystemen von Verbrennungsmotoren

    Energy Technology Data Exchange (ETDEWEB)

    Augustin, Silke; Froehlich, Thomas; Mammen, Helge [Technische Univ. Illmenau (Germany). Inst. fuer Prozessmess- und Sensortechnik; Ament, Christoph; Guether, Thomas [Technische Univ. Illmenau (Germany). Inst. fuer Automatisierungs- und Systemtechnik

    2012-11-01

    Thermocouples used in exhaust systems of combustion engines are exposed to high temperature gradients and temperature leaps ({Delta}T > 900 K), high flow speeds and pressure. When constructing these thermocouples, a compromise is needed between the resulting high demands on the mechanical-thermal stability, accuracy and the fast response time demanded by the servo-control of the motors. Additionally, a numerical correction of the measured signal may contribute to an improved sensor dynamics. (orig.)

  2. Plasma methoxytyramine: A novel biomarker of metastatic pheochromocytoma and paraganglioma in relation to established risk factors of tumor size, location and SDHB mutation status

    Science.gov (United States)

    Eisenhofer, Graeme; Lenders, Jacques W.M.; Siegert, Gabriele; Bornstein, Stefan R.; Friberg, Peter; Milosevic, Dragana; Mannelli, Massimo; Linehan, W. Marston; Adams, Karen; Timmers, Henri J.; Pacak, Karel

    2012-01-01

    Summary Background There are currently no reliable biomarkers for malignant pheochromocytomas and paragangliomas (PPGLs). This study examined whether measurements of catecholamines and their metabolites might offer utility for this purpose. Methods Subjects included 365 patients with PPGLs, including 105 with metastases, and a reference population of 846 without the tumor. Eighteen catecholamine-related analytes were examined in relation to tumor location, size and mutations of succinate dehydrogenase subunit B (SDHB). Results Receiver-operating characteristic curves indicated that plasma methoxytyramine, the O-methylated metabolite of dopamine, provided the most accurate biomarker for discriminating patients with and without metastases. Plasma methoxytyramine was 4.7-fold higher in patients with than without metastases, a difference independent of tumor burden and the associated 1.6- to 1.8-fold higher concentrations of norepinephrine and normetanephrine. Increased plasma methoxytyramine was associated with SDHB mutations and extra-adrenal disease, but was also present in patients without SDHB mutations and metastases or those with metastases secondary to adrenal tumors. High risk of malignancy associated with SDHB mutations reflected large size and extra-adrenal locations of tumors, both independent predictors of metastatic disease. A plasma methoxytyramine above 0.2 nmol/L or a tumor diameter above 5 cm indicated increased likelihood of metastatic spread, particularly when associated with an extra-adrenal location. Interpretation Plasma methoxytyramine is a novel biomarker for metastatic PPGLs that together with SDHB mutation status, tumor size and location provide useful information to assess the likelihood of malignancy and manage affected patients. PMID:22036874

  3. AGR-1 Thermocouple Data Analysis

    International Nuclear Information System (INIS)

    Einerson, Jeff

    2012-01-01

    This report documents an effort to analyze measured and simulated data obtained in the Advanced Gas Reactor (AGR) fuel irradiation test program conducted in the INL's Advanced Test Reactor (ATR) to support the Next Generation Nuclear Plant (NGNP) R and D program. The work follows up on a previous study (Pham and Einerson, 2010), in which statistical analysis methods were applied for AGR-1 thermocouple data qualification. The present work exercises the idea that, while recognizing uncertainties inherent in physics and thermal simulations of the AGR-1 test, results of the numerical simulations can be used in combination with the statistical analysis methods to further improve qualification of measured data. Additionally, the combined analysis of measured and simulation data can generate insights about simulation model uncertainty that can be useful for model improvement. This report also describes an experimental control procedure to maintain fuel target temperature in the future AGR tests using regression relationships that include simulation results. The report is organized into four chapters. Chapter 1 introduces the AGR Fuel Development and Qualification program, AGR-1 test configuration and test procedure, overview of AGR-1 measured data, and overview of physics and thermal simulation, including modeling assumptions and uncertainties. A brief summary of statistical analysis methods developed in (Pham and Einerson 2010) for AGR-1 measured data qualification within NGNP Data Management and Analysis System (NDMAS) is also included for completeness. Chapters 2-3 describe and discuss cases, in which the combined use of experimental and simulation data is realized. A set of issues associated with measurement and modeling uncertainties resulted from the combined analysis are identified. This includes demonstration that such a combined analysis led to important insights for reducing uncertainty in presentation of AGR-1 measured data (Chapter 2) and interpretation of

  4. AGR-1 Thermocouple Data Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Jeff Einerson

    2012-05-01

    This report documents an effort to analyze measured and simulated data obtained in the Advanced Gas Reactor (AGR) fuel irradiation test program conducted in the INL's Advanced Test Reactor (ATR) to support the Next Generation Nuclear Plant (NGNP) R&D program. The work follows up on a previous study (Pham and Einerson, 2010), in which statistical analysis methods were applied for AGR-1 thermocouple data qualification. The present work exercises the idea that, while recognizing uncertainties inherent in physics and thermal simulations of the AGR-1 test, results of the numerical simulations can be used in combination with the statistical analysis methods to further improve qualification of measured data. Additionally, the combined analysis of measured and simulation data can generate insights about simulation model uncertainty that can be useful for model improvement. This report also describes an experimental control procedure to maintain fuel target temperature in the future AGR tests using regression relationships that include simulation results. The report is organized into four chapters. Chapter 1 introduces the AGR Fuel Development and Qualification program, AGR-1 test configuration and test procedure, overview of AGR-1 measured data, and overview of physics and thermal simulation, including modeling assumptions and uncertainties. A brief summary of statistical analysis methods developed in (Pham and Einerson 2010) for AGR-1 measured data qualification within NGNP Data Management and Analysis System (NDMAS) is also included for completeness. Chapters 2-3 describe and discuss cases, in which the combined use of experimental and simulation data is realized. A set of issues associated with measurement and modeling uncertainties resulted from the combined analysis are identified. This includes demonstration that such a combined analysis led to important insights for reducing uncertainty in presentation of AGR-1 measured data (Chapter 2) and interpretation of

  5. Pleomorphic Adenoma of Breast: A Radiological and Pathological Study of a Common Tumor in an Uncommon Location

    Directory of Open Access Journals (Sweden)

    Paula S. Ginter

    2015-01-01

    Full Text Available Pleomorphic adenoma occurs commonly in the major salivary glands but is uncommonly encountered in the breast. In both of these locations, the tumor is typically grossly circumscribed and has a “mixed” histological appearance, being composed of myoepithelial and epithelial components amid a myxochondroid matrix. Herein, we report a case of pleomorphic adenoma of the breast which was preoperatively thought to represent a fibroadenoma on clinical and radiological grounds. It is the rarity of the tumor in the breast, rather than its histological appearance, that causes diagnostic difficulty.

  6. Experience with W3Re/W25Re thermocouples in fuel pins of NS Otto Hahn's two cores

    International Nuclear Information System (INIS)

    Kolb, M.

    1976-01-01

    The paper first deals with the installation of 18 and 9 high-temperature sheathed thermocouples in fuel rods of the cores FDR-1 and FDR-2, respectively. The measured fuel rod centerline temperatures could be related to the local linear rod power at any given time by means of the densities of fission products with different half-lives obtained from fuel rod γ-scans. The fuel temperatures show then already an increase with the burn-up of the FDR-1 which becomes steeper when taking into account the decrease of the EMF measured at irradiated thermocouples taken from the fuel rods. Finally, the determination of effective thermocouple time constants and of fuel rod heat transfer time constants is demonstrated by utilizing the reactor noise to measure the transfer function between neutron flux and fuel temperature signal. (orig.) [de

  7. Calibration of the Dodewaard downcomer thermocouple cross-correlation flow-rate measurements

    Energy Technology Data Exchange (ETDEWEB)

    Stekelenburg, A J.C. [Technische Univ. Delft (Netherlands). Interfacultair Reactor Inst.; Hagen, T.H.J.J. van der [Technische Univ. Delft (Netherlands). Interfacultair Reactor Inst.; Akker, H.E.A. van den [Technische Univ. Delft (Netherlands). Lab. voor Fysische Technologie

    1992-12-01

    The cross-correlation flow measurement technique, applied for measuring the coolant flow rate in a nuclear reactor, was calibrated with the use of numerical simulations of turbulent flow. The three-dimensional domain was collapsed into two dimensions. With a two-dimensional calculation of steady-state flow with transient thermal characteristics the response of thermocouples to a temperature variation was calculated. By cross-correlating the calculated thermocouple responses, the link between total flow rate and measured transit times was made. Three calibration points were taken in the range of 579 kg/s to 1477 kg/s. In this range, the product of the calculated transit time and the mass flow-rate is constant up to +3.5% and -2.4%. The reliability of the calibration was estimated at {+-}4.6%. The influence of the inlet boundary conditions, and the modelling of the flow in the upper part of the downcomer channel on the calibration result is shown to be small. A measured velocity profile effect was successfully predicted. (orig.).

  8. Clinical impact of tumor location on the colon cancer survival and recurrence: analyses of pooled data from three large phase III randomized clinical trials.

    Science.gov (United States)

    Aoyama, Toru; Kashiwabara, Kosuke; Oba, Koji; Honda, Michitaka; Sadahiro, Sotaro; Hamada, Chikuma; Maeda, Hiromichi; Mayanagi, Shuhei; Kanda, Mitsuro; Sakamoto, Junichi; Saji, Shigetoyo; Yoshikawa, Takaki

    2017-11-01

    The aim of the present study was to determine whether or not the overall survival (OS) and disease-free survival (DFS) were affected by the tumor location in patients who underwent curative resection for colon cancer in a pooled analysis of three large phase III studies performed in Japan. In total, 4029 patients were included in the present study. Patients were classified as having right-side colon cancer (RC) if the primary tumor was located in the cecum, ascending colon, hepatic flexure or transverse colon, and left-side colon cancer (LCC) if the tumor site was within the splenic flexure, descending colon, sigmoid colon or recto sigmoid junction. The risk factors for the OS and DFS were analyzed. In the present study, 1449 patients were RC, and 2580 were LCC. The OS rates at 3 and 5 years after surgery were 87.6% and 81.6% in the RC group and 91.5% and 84.5% in the LCC group, respectively. Uni- and multivariate analyses showed that RRC increased the risk of death by 19.7% (adjusted hazard ratio = 1.197; 95% confidence interval, 1.020-1.408; P = 0.0272). In contrast, the DFS was similar between the two locations. The present study confirmed that the tumor location was a risk factor for the OS in patients who underwent curative treatment for colon cancer. Tumor location may, therefore, need to be considered a stratification factor in future phase III trials of colon cancer. © 2017 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  9. Recommendations for the specification of thermocouples for nuclear applications

    International Nuclear Information System (INIS)

    1977-05-01

    This Code of Practice is a guide for use in the preparation of individual specifications to cover, as fully as possible the conditions governing the supply of raw materials and the ordering, manufacture, testing, inspection, handling and installation of thermocouples for use in nuclear environments in order that reliable, consistent and generally acceptable results can be obtained. The insulation resistance values quoted in this document apply to magnesium oxide. If other insulants are called for, appropriate values must be specified. (author)

  10. Peculiarities in the CT findings of germ cell tumors in various tumor localizations

    International Nuclear Information System (INIS)

    Tazoe, Makoto; Miyagami, Mitsusuke; Tsubokawa, Takashi

    1991-01-01

    The CT findings of 17 germ cell tumors were studied in relation to the locations of the tumor, the pathological diagnoses, and the tumor markers (AFP and HCG). Generally, the CT findings of germ cell tumors depended on the pathological diagnoses more strongly than on the location of the tumors. On plain CT of 7 germ cell tumors in the pineal region, all of them demonstrated heterogeneous findings. Hydrocephalus was seen in 6 cases (86%) and calcification in 6 cases (86%) of the germ cell tumors in the pineal region. Calcification and hydrocephalus that appeared more often than in other regions were characteristic of germ cell tumors of the pineal region. The germ cell tumors in the basal ganglia had a slightly homogenous high density, with small cysts and calcification in most of them on plain CT. On enhanced CT, the tumors were moderately enhanced in all cases located in the basal ganglia. Four cases of germ cell tumors located in the basal ganglia revealed the dilatation of lateral ventricle due to hemispheric atrophy in the tumor side. The germ cell tumors showing an increase in the tumor markers such as AFP and HCG, which were usually malignant germ cell tumors, were strongly enhanced on enhanced CT. (author)

  11. Comparison study of the partial-breast irradiation techniques: Dosimetric analysis of three-dimensional conformal radiation therapy, electron beam therapy, and helical tomotherapy depending on various tumor locations

    International Nuclear Information System (INIS)

    Kim, Min-Joo; Park, So-Hyun; Son, Seok-Hyun; Cheon, Keum-Seong; Choi, Byung-Ock; Suh, Tae-Suk

    2013-01-01

    The partial-breast irradiation (PBI) technique, an alternative to whole-breast irradiation, is a beam delivery method that uses a limited range of treatment volume. The present study was designed to determine the optimal PBI treatment modalities for 8 different tumor locations. Treatment planning was performed on computed tomography (CT) data sets of 6 patients who had received lumpectomy treatments. Tumor locations were classified into 8 subsections according to breast quadrant and depth. Three-dimensional conformal radiation therapy (3D-CRT), electron beam therapy (ET), and helical tomotherapy (H-TOMO) were utilized to evaluate the dosimetric effect for each tumor location. Conformation number (CN), radical dose homogeneity index (rDHI), and dose delivered to healthy tissue were estimated. The Kruskal-Wallis, Mann-Whitney U, and Bonferroni tests were used for statistical analysis. The ET approach showed good sparing effects and acceptable target coverage for the lower inner quadrant—superficial (LIQ-S) and lower inner quadrant—deep (LIQ-D) locations. The H-TOMO method was the least effective technique as no evaluation index achieved superiority for all tumor locations except CN. The ET method is advisable for treating LIQ-S and LIQ-D tumors, as opposed to 3D-CRT or H-TOMO, because of acceptable target coverage and much lower dose applied to surrounding tissue

  12. Impact of Primary Tumor Location on First-line Bevacizumab or Cetuximab in Metastatic Colorectal Cancer.

    Science.gov (United States)

    Snyder, Matthew; Bottiglieri, Sal; Almhanna, Khaldoun

    2018-01-01

    Colorectal cancer is one of the most common malignancies in the United States, with a large proportion of patients presenting with metastatic disease or developing a recurrence. Systemic chemotherapy is the mainstay of therapy in this setting. There is a clear benefit in the addition of bevacizumab or cetuximab (for rat sarcoma [RAS] wild type tumors) to oxaliplatin- and irinotecan-based regimens which can be considered for first-line therapy. However, many significant questions remain as to which agent reflects best practice. Our review aimed to elucidate the benefit of adding bevacizumab and cetuximab to initial therapy for metastatic colorectal cancer based on primary tumor location and a variety of other disease- and patient-related factors, addressing the paucity of evidence that currently exists in this area and contributing to current literature and clinical practices. The primary endpoints of the study were first Progression-Free Survival (PFS) and Overall Survival (OS). Secondary endpoints included best response to first- and second-line therapies, Treatment- Related Adverse Events (TRAEs), second PFS, cost of therapy, and an assessment of other patient- and disease-related factors affecting PFS and OS. While there were trends towards improved OS in patients with left-sided primary tumors (n=57) compared to those with right-sided disease (n=23), there were no significant differences between the two groups in either primary endpoint. While no differences were found for patients with left- or right- sided tumors stratified by add-on agent, these analyses were limited by the small number of patients receiving cetuximab with first-line therapy (n=4). However, the bevacizumab cohort (n=76) was sizable enough to provide ample data and produce clinically relevant results. Add-on therapy with bevacizumab in our study achieved impressive survival outcomes in both left-sided (median first PFS = 13 months, 95% CI 11-15 months; median OS = 37 months, 95% CI 21

  13. Use of indexed sensitivity factors in the analysis of nickel and iron based alloys: study of the decalibration of sheathed Chromel/Alumel thermocouples

    International Nuclear Information System (INIS)

    Christie, W.H.

    1978-01-01

    Sheathed Chromel versus Alumel thermocouples decalibrate when exposed to temperatures in excess of 1100 0 C. Thermocouples sheathed in Inconel-600 and type 304 stainless steel were studied in this work. Quantified SIMS data showed that the observed decalibrations were due to significant alterations that took place in the Chromel and Alumel thermoelements. The amount of alteration was different for each thermocouple and was influenced by the particular sheath material used in the thermocouple construction. Relative sensitivity factors, indexed by a matrix ion species ratio, were used to quantify SIMS data for three nickel-based alloys, Chromel, Alumel, and Inconel-600, and an iron-based alloy, type 304 stainless steel. Oxygen pressure >2 x 10 -6 torr in the sputtering region gave enhanced sensitivity and superior quantitative results as compared to data obtained at instrumental residual pressure

  14. Computer subroutines to aid analysis of experimental data from thermocouples and pressure transducers

    International Nuclear Information System (INIS)

    Durham, M.E.

    1976-08-01

    Three subroutines (CALSET, CALBR8 and PTRCAL) have been written to provide a convenient system for converting experimental measurements obtained from thermocouples and pressure transducers to temperatures and pressures. The method of operation and the application of the subroutines are described. (author)

  15. Effect of Primary Tumor Location on Second- or Later-line Treatment Outcomes in Patients With RAS Wild-type Metastatic Colorectal Cancer and All Treatment Lines in Patients With RAS Mutations in Four Randomized Panitumumab Studies.

    Science.gov (United States)

    Boeckx, Nele; Koukakis, Reija; Op de Beeck, Ken; Rolfo, Christian; Van Camp, Guy; Siena, Salvatore; Tabernero, Josep; Douillard, Jean-Yves; André, Thierry; Peeters, Marc

    2018-03-08

    The primary tumor location has a prognostic impact in metastatic colorectal cancer (mCRC). We report the results from retrospective analyses assessing the effect of tumor location on prognosis and efficacy of second- and later-line panitumumab treatment in patients with RAS wild-type (WT) mCRC and on prognosis in all lines of treatment in patients with RAS mutant (MT) mCRC. RAS WT data (n = 483) from 2 randomized phase III panitumumab trials (ClinicalTrials.gov identifiers, NCT00339183 and NCT00113763) were analyzed for treatment outcomes stratified by tumor location. The second analysis assessed the effect of tumor location in RAS MT patients (n = 1205) from 4 panitumumab studies (ClinicalTrials.gov identifiers, NCT00364013, NCT00819780, NCT00339183, and NCT00113763). Primary tumors located in the cecum to transverse colon were coded as right-sided; those located from the splenic flexure to the rectum were coded as left-sided. Of all patients, the tumor location was ascertained for 83% to 88%; 71% to 77% of patients had left-sided tumors. RAS WT patients with right-sided tumors did worse for all efficacy parameters compared with those with left-sided tumors. The patients with left-sided tumors had better outcomes with panitumumab than with the comparator treatment. Because of the low patient numbers, no conclusions could be drawn for right-sided mCRC. The prognostic effect of tumor location on survival was unclear for RAS MT patients. These retrospective analyses have confirmed that RAS WT right-sided mCRC is associated with a poor prognosis, regardless of the treatment. RAS WT patients with left-sided tumors benefitted from the addition of panitumumab in second or later treatment lines. Further research is warranted to determine the optimum management of right-sided mCRC and RAS MT tumors. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. Quantification analysis of the expression of tumor-associated proteins in serum samples from patients with ovarian cancer and those with other tumor location. Possibilities of their use in the diagnosis and estimation of the extent of a tumorous process

    Directory of Open Access Journals (Sweden)

    T. S. Bobrova

    2012-01-01

    Full Text Available The specific features of the expression of tumor-associated proteins (TAP were immunologically studied in the sera of patients with ovarian cancer (OC and other tumor location by means of immune sera (As or monoclonal antibodies (MAb to find out whether they could be used to diagnose and estimate the extent of a tumorous process.MAb 1 (to HEp-2 cell membrane proteins, larynx cancer, Ac4 (to a pool of two ovarian cystadenocarcinomas, and MAb 3 (to affinity-pu- rified proteins of the apparently intact human gastric mucosa were used to examine the sera of patients with OC and other tumor location and positive responsiveness was detected in 82, ~100, and 77 % of cases, respectively. The differences in the expression of TAP in the patients versus healthy donors were shown to be statistically significant (p = 0.0001; p = 0.015; p = 0.01, respectively.The sensitivity of quantifying ELISA in detecting TAP was 78 and 85 % in patients with Stages I–II and III–IV OC, respectively; ~100 and 89 % in patients with breast cancer and in those with gastrointestinal tract cancer, respectively; and 60 and 14 % in patients with lymphopro- liferative diseases and healthy donors, respectively. Comparison of TAP detection rates in the authors’ test systems with multiplex testing with a biochip array of 12 tumor markers has shown that these test systems are at the world standard level.

  17. Techniques for heating eccentrically located tumors with the BSD annular phased array system (APAS): Clinical experience

    International Nuclear Information System (INIS)

    Samulski, T.V.; Kapp, D.S.; Bagshaw, M.A.; Fessenden, P.; Lee, E.R.; Lohrbach, A.W.

    1985-01-01

    The authors are currently investigating the potential for treatment optimization with the BSD APAS in tumors which are eccentrically located within the lower abdomen and pelvis. Attempts have been made to manipulate electric field (E-field) distribution during treatments through frequency changes and partial array activation (driving less than all four quadrants). Field shifts are qualitatively documented using the manufacturer's supplied diode array probes located at the patient/bolus interface in anterior, posterior and bilateral positions. Preliminary findings indicate that the internal E-field distributions can be manipulated to result in better treatment tolerance and better temperature distributions in selected target volumes. Phantom and clinical data are presented demonstrating the utility of these approaches

  18. Measurement errors for thermocouples attached to thin plates

    International Nuclear Information System (INIS)

    Sobolik, K.B.; Keltner, N.R.; Beck, J.V.

    1989-01-01

    This paper discusses Unsteady Surface Element (USE) methods which are applied to a model of a thermocouple wire attached to a thin disk. Green's functions are used to develop the integral equations for the wire and the disk. The model can be used to evaluate transient and steady state responses for many types of heat flux measurement devices including thin skin calorimeters and circular foil (Gardon) head flux gauges. The model can accommodate either surface or volumetric heating of the disk. The boundary condition at the outer radius of the disk can be either insulated or constant temperature. Effect on the errors of geometrical and thermal factors can be assessed. Examples are given

  19. Detection of thermocouple malfunction in the Beacon system

    International Nuclear Information System (INIS)

    Morita, T.; Heibel, M.D.; Congedo, T.V.

    1992-01-01

    The BEACON system uses Core Exit Thermocouples (T/C) extensively for continuous radial power distribution monitoring. The T/C's are used to adjust the reference power distribution generated by the BEACON system to match the current radial power distribution. T/C reliability, repeatability, and relative accuracy have been very satisfactory. However, it is very important to detect any T/C malfunctions during operation, since a T/C signal change caused by an undetected malfunction can lead to serious errors in the radial power distribution developed by BEACON. A simple procedure has been developed which is capable of discriminating between changes in T/C signals caused by actual changes in reactor conditions and signal changes caused by T/C malfunctions

  20. Does the pretreatment tumor sampling location correspond with metabolic activity on 18F-FDG PET/CT in breast cancer patients scheduled for neoadjuvant chemotherapy?

    Energy Technology Data Exchange (ETDEWEB)

    Koolen, Bas B., E-mail: b.koolen@nki.nl [Department of Nuclear Medicine, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Department of Surgical Oncology, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Elshof, Lotte E. [Department of Nuclear Medicine, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Department of Surgical Oncology, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Loo, Claudette E. [Department of Radiology, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Wesseling, Jelle [Department of Pathology, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Vrancken Peeters, Marie-Jeanne T.F.D. [Department of Surgical Oncology, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Vogel, Wouter V. [Department of Nuclear Medicine, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Rutgers, Emiel J.Th. [Department of Surgical Oncology, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Valdés Olmos, Renato A. [Department of Nuclear Medicine, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands)

    2013-12-01

    Purpose: To define the correlation between the core biopsy location and the area with highest metabolic activity on 18F-FDG PET/CT in stage II–III breast cancer patients before neoadjuvant chemotherapy. Also, we would like to select a subgroup of patients in which PET/CT information may optimize tumor sampling. Methods: A PET/CT in prone position was acquired in 199 patients with 203 tumors. The distance and relative difference in standardized uptake value (SUV) between core biopsy localization (indicated by a marker) and area with highest degree of FDG uptake were evaluated. A distance ≥2 cm and a relative difference in SUV ≥25% were considered clinically relevant and a combination of both was defined as non-correspondence. Non-correspondence for different tumor characteristics (TNM stage, lesion morphology on MRI and PET/CT, histology, subtype, grade, and Ki-67) was assessed. Results: Non-correspondence was found in 28 (14%) of 203 tumors. Non-correspondence was significantly associated with T-stage, lesion morphology on MRI and PET/CT, tumor diameter, and histologic type. It was more often seen in tumors with a higher T-stage (p = 0.028), diffuse (non-mass) and multifocal tumors on MRI (p = 0.001), diffuse and multifocal tumors on PET/CT (p < 0.001), tumors >3 cm (p < 0.001), and lobular carcinomas (p < 0.001). No association was found with other features. Conclusion: Non-correspondence between the core biopsy location and area with highest FDG uptake is regularly seen in stage II–III breast cancer patients. PET/CT information and possibly FDG-guided biopsies are most likely to improve pretreatment tumor sampling in tumors >3 cm, lobular carcinomas, and diffuse and multifocal tumors.

  1. Optimum location of external markers using feature selection algorithms for real-time tumor tracking in external-beam radiotherapy: a virtual phantom study.

    Science.gov (United States)

    Nankali, Saber; Torshabi, Ahmad Esmaili; Miandoab, Payam Samadi; Baghizadeh, Amin

    2016-01-08

    In external-beam radiotherapy, using external markers is one of the most reliable tools to predict tumor position, in clinical applications. The main challenge in this approach is tumor motion tracking with highest accuracy that depends heavily on external markers location, and this issue is the objective of this study. Four commercially available feature selection algorithms entitled 1) Correlation-based Feature Selection, 2) Classifier, 3) Principal Components, and 4) Relief were proposed to find optimum location of external markers in combination with two "Genetic" and "Ranker" searching procedures. The performance of these algorithms has been evaluated using four-dimensional extended cardiac-torso anthropomorphic phantom. Six tumors in lung, three tumors in liver, and 49 points on the thorax surface were taken into account to simulate internal and external motions, respectively. The root mean square error of an adaptive neuro-fuzzy inference system (ANFIS) as prediction model was considered as metric for quantitatively evaluating the performance of proposed feature selection algorithms. To do this, the thorax surface region was divided into nine smaller segments and predefined tumors motion was predicted by ANFIS using external motion data of given markers at each small segment, separately. Our comparative results showed that all feature selection algorithms can reasonably select specific external markers from those segments where the root mean square error of the ANFIS model is minimum. Moreover, the performance accuracy of proposed feature selection algorithms was compared, separately. For this, each tumor motion was predicted using motion data of those external markers selected by each feature selection algorithm. Duncan statistical test, followed by F-test, on final results reflected that all proposed feature selection algorithms have the same performance accuracy for lung tumors. But for liver tumors, a correlation-based feature selection algorithm, in

  2. Predicting location of recurrence using FDG, FLT, and Cu-ATSM PET in canine sinonasal tumors treated with radiotherapy

    International Nuclear Information System (INIS)

    Bradshaw, Tyler; Jeraj, Robert; Fu, Rau; Zhu, Jun; Bowen, Stephen; Forrest, Lisa

    2015-01-01

    Dose painting relies on the ability of functional imaging to identify resistant tumor subvolumes to be targeted for additional boosting. This work assessed the ability of FDG, FLT, and Cu-ATSM PET imaging to predict the locations of residual FDG PET in canine tumors following radiotherapy. Nineteen canines with spontaneous sinonasal tumors underwent PET/CT imaging with radiotracers FDG, FLT, and Cu-ATSM prior to hypofractionated radiotherapy. Therapy consisted of 10 fractions of 4.2 Gy to the sinonasal cavity with or without an integrated boost of 0.8 Gy to the GTV. Patients had an additional FLT PET/CT scan after fraction 2, a Cu-ATSM PET/CT scan after fraction 3, and follow-up FDG PET/CT scans after radiotherapy. Following image registration, simple and multiple linear and logistic voxel regressions were performed to assess how well pre- and mid-treatment PET imaging predicted post-treatment FDG uptake. R 2 and pseudo R 2 were used to assess the goodness of fits. For simple linear regression models, regression coefficients for all pre- and mid-treatment PET images were significantly positive across the population (P < 0.05). However, there was large variability among patients in goodness of fits: R 2 ranged from 0.00 to 0.85, with a median of 0.12. Results for logistic regression models were similar. Multiple linear regression models resulted in better fits (median R 2 = 0.31), but there was still large variability between patients in R 2 . The R 2 from regression models for different predictor variables were highly correlated across patients (R ≈ 0.8), indicating tumors that were poorly predicted with one tracer were also poorly predicted by other tracers. In conclusion, the high inter-patient variability in goodness of fits indicates that PET was able to predict locations of residual tumor in some patients, but not others. This suggests not all patients would be good candidates for dose painting based on a single biological target. (paper)

  3. Relation between the location of elements in the Thomsen-Bohr type periodic table and lysosomal accumulation in tumor and liver

    International Nuclear Information System (INIS)

    Ando, Atsushi; Ando, Itsuko

    1989-01-01

    This study was undertaken to evaluate the lysosomal accumulation of radioactive metal ions in tumor and liver, using tumor-bearing animals. From the experimental of lysosomal accumulation and binding substance for nineteen radioactive metal ions, the following results were obtained. Hard and borderline acids which have incomplete d-shells accumulated extensively in lysosomes of tumor and liver with time after administration of these ions. They were bound in these tissues to the acid mucopolysaccharides whose molecular weights exceed 40,000 daltons. Trivalent hard acids (Ga 3+ , In 3+ , Yb 3+ , Tm 3+ ) which have complete d-shells accumulated extensively in the lysosomes of liver, but very little in lysososmes of tumor, and were bound to the acid mucopolysaccharide with a molecular weight of about 10,000 daltons in tissues. It was clear based on these results and the facts reported previously that a very interesting relationship existed between the location of elements in the Thomsen-Bohr type periodic table and the lysosomal accumulation of metal ions

  4. Functional rearrangement of the primary and secondary motor cortex in patients with primary tumors of the central nervous system located in the region of the central sulcus depending on the histopathological type and the size of tumor: Examination by means of functional magnetic resonance imaging

    International Nuclear Information System (INIS)

    Bryszewski, Bartosz; Pfajfer, Lucjan; Antosik-Biernacka, Aneta; Tybor, Krzysztof; Śmigielski, Janusz; Zawirski, Marek; Majos, Agata

    2012-01-01

    The aim of this study was to analyze the reorganization of the centers of the motor cortex in patients with primary neuroepithelial tumors of the central nervous system (CNS) located in the region of the central sulcus in relation to the histopathological type and the size of tumor, as determined by means of functional magnetic resonance imaging (fMRI). The fMRI was performed prior to the surgical treatment of patients with tumors located in the region of the central sulcus (WHO stage I and II, n=15; WHO stage III and IV, n=25). The analysis included a record of the activity in the areas of the primary motor cortex (M1) and the secondary motor cortex: the premotor cortex (PMA) and the accessory motor area (SMA). The results were correlated with the histopathological type of the tumor and its size expressed in cm 3 . The frequency of activation of the motor center was higher in the group of patients who had less aggressive tumors, such as low-grade glioma (LGG), as well as in tumors of lower volume, and this was true both for the hemisphere where the tumor was located and in the contralateral one. Mean values of t-statistics of activation intensity, mean numbers of activated clusters, and their ranges were lower in all analyzed motor areas of LGG tumors. The values of t-statistics and activation areas were higher in the case of small tumors located in ipsilateral centers, and in large tumors located in contralateral centers, aside from the SMA area where the values of t-statistics were equal for both groups. The contralateral SMA area was characterized by the highest stability of all examined centers of secondary motor cortex. No significant association (p>0.05) was observed between the absolute value of the mean registered activity (t-statistics) and the size of examined areas (number of clusters) when the groups were stratified with regards to the analyzed parameters. The presence of a neoplastic lesion, its histopathological type and finally its size modulate the

  5. Optimum location of external markers using feature selection algorithms for real‐time tumor tracking in external‐beam radiotherapy: a virtual phantom study

    Science.gov (United States)

    Nankali, Saber; Miandoab, Payam Samadi; Baghizadeh, Amin

    2016-01-01

    In external‐beam radiotherapy, using external markers is one of the most reliable tools to predict tumor position, in clinical applications. The main challenge in this approach is tumor motion tracking with highest accuracy that depends heavily on external markers location, and this issue is the objective of this study. Four commercially available feature selection algorithms entitled 1) Correlation‐based Feature Selection, 2) Classifier, 3) Principal Components, and 4) Relief were proposed to find optimum location of external markers in combination with two “Genetic” and “Ranker” searching procedures. The performance of these algorithms has been evaluated using four‐dimensional extended cardiac‐torso anthropomorphic phantom. Six tumors in lung, three tumors in liver, and 49 points on the thorax surface were taken into account to simulate internal and external motions, respectively. The root mean square error of an adaptive neuro‐fuzzy inference system (ANFIS) as prediction model was considered as metric for quantitatively evaluating the performance of proposed feature selection algorithms. To do this, the thorax surface region was divided into nine smaller segments and predefined tumors motion was predicted by ANFIS using external motion data of given markers at each small segment, separately. Our comparative results showed that all feature selection algorithms can reasonably select specific external markers from those segments where the root mean square error of the ANFIS model is minimum. Moreover, the performance accuracy of proposed feature selection algorithms was compared, separately. For this, each tumor motion was predicted using motion data of those external markers selected by each feature selection algorithm. Duncan statistical test, followed by F‐test, on final results reflected that all proposed feature selection algorithms have the same performance accuracy for lung tumors. But for liver tumors, a correlation‐based feature

  6. Sinus Tumors

    Science.gov (United States)

    ... RESOURCES Medical Societies Patient Education About this Website Font Size + - Home > CONDITIONS > Sinus Tumors Adult Sinusitis Pediatric ... and they vary greatly in location, size and type. Care for these tumors is individualized to each ...

  7. Glomus Tumor of Thumb Occurring at Unusual Location

    African Journals Online (AJOL)

    diagnosis of glomus tumour. Although rare, glomus tumour should be considered as differential diagnosis for fingertip ... Figure 1: Radiograph-anteropsterior and lateral view ... nail bed is carefully dissected from the bone until the tumor.

  8. Calculation errors of Set-up in patients with tumor location of prostate. Exploratory study; Calculo de errores de Set-up en pacientes con localizacion tumoral de prostata. Estudio exploratorio

    Energy Technology Data Exchange (ETDEWEB)

    Donis Gil, S.; Robayna Duque, B. E.; Jimenez Sosa, A.; Hernandez Armas, O.; Gonzalez Martin, A. E.; Hernandez Armas, J.

    2013-07-01

    The calculation of SM is done from errors in positioning (set-up). These errors are calculated from movements in 3D of the patient. This paper is an exploratory study of 20 patients with tumor location of prostate in which errors of set-up for two protocols of work are evaluated. (Author)

  9. Characteristics of intraoperative abnormal hemodynamics during resection of an intra-fourth ventricular tumor located on the dorsal medulla oblongata.

    Science.gov (United States)

    Ideguchi, Makoto; Kajiwara, Koji; Yoshikawa, Koichi; Sadahiro, Hirokazu; Nomura, Sadahiro; Fujii, Masami; Suzuki, Michiyasu

    2013-01-01

    Abnormal hemodynamics during extirpation of a para-medulla oblongata (MO) tumor is common and may be associated with direct vagal stimulation of the medullary circuit. However, resection of tumors on the dorsal MO may also induce hemodynamic instability without direct vagal stimulus. The objective of this study was to examine the characteristics of hemodynamic instability unrelated to vagal stimulus during dissection of an intra-fourth ventricular tumor with attachment to the dorsal MO. A retrospective analysis was performed in 13 patients. Abnormal hemodynamics were defined as a > 20% change from the means of the intraoperative mean arterial pressure (MAP) and heart rate (HR). Relationships of intraoperative hemodynamics were evaluated with various parameters, including the volume of the MO. Six patients (46.2%) had intraoperative hypertension during separation of the tumor bulk from the dorsal MO. The maximum MAP and HR in these patients were significantly greater than those in patients with normal hemodynamics (116.0 ± 18.0 mmHg versus 85.6 ± 6.5 mmHg; 124.3 ± 22.8 bpm versus 90.5 ± 14.7 bpm). All six cases with abnormal hemodynamics showed hemodynamic fluctuation during separation of the tumor bulk from the dorsal MO. The preoperative volume of the MO in these patients was 1.11 cc less than that in patients with normal hemodynamics, but the volume after tumor resection was similar in the two groups (5.23 cc and 5.12 cc). This suggests that the MO was compressed by the conglutinate tumor bulk, with resultant fluctuation of hemodynamics. Recognition of and preparation for this phenomenon are important for surgery on a tumor located on the dorsal MO.

  10. New fixed-point mini-cell to investigate thermocouple drift in a high-temperature environment under neutron irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Laurie, M.; Vlahovic, L.; Rondinella, V.V. [European Commission, Joint Research Centre, Institute for Transuranium Elements, P.O. Box 2340, D-76125 Karlsruhe, (Germany); Sadli, M.; Failleau, G. [Laboratoire Commun de Metrologie, LNE-Cnam, Saint-Denis, (France); Fuetterer, M.; Lapetite, J.M. [European Commission, Joint Research Centre, Institute for Energy and Transport, P.O. Box 2, NL-1755 ZG Petten, (Netherlands); Fourrez, S. [Thermocoax, 8 rue du pre neuf, F-61100 St Georges des Groseillers, (France)

    2015-07-01

    Temperature measurements in the nuclear field require a high degree of reliability and accuracy. Despite their sheathed form, thermocouples subjected to nuclear radiations undergo changes due to radiation damage and transmutation that lead to significant EMF drift during long-term fuel irradiation experiment. For the purpose of a High Temperature Reactor fuel irradiation to take place in the High Flux Reactor Petten, a dedicated fixed-point cell was jointly developed by LNE-Cnam and JRC-IET. The developed cell to be housed in the irradiation rig was tailor made to quantify the thermocouple drift during the irradiation (about two year duration) and withstand high temperature (in the range 950 deg. C - 1100 deg. C) in the presence of contaminated helium in a graphite environment. Considering the different levels of temperature achieved in the irradiation facility and the large palette of thermocouple types aimed at surveying the HTR fuel pebble during the qualification test both copper (1084.62 deg. C) and gold (1064.18 deg. C) fixed-point materials were considered. The aim of this paper is to first describe the fixed-point mini-cell designed to be embedded in the reactor rig and to discuss the preliminary results achieved during some out of pile tests as much as some robustness tests representative of the reactor scram scenarios. (authors)

  11. External attachment of titanium sheathed thermocouples to zirconium nuclear fuel rods for the LOFT reactor

    International Nuclear Information System (INIS)

    Welty, R.K.

    1980-01-01

    The Exxon Nuclear Company, Inc., acting as a Subcontractor to EG and G Idaho Inc., Idaho National Engineering Laboratory, Idaho Falls, Idaho, has developed a welding process to attach titanium sheathed thermocouples to the outside of the zircaloy clad fuel rods. The fuel rods and thermocouples are used to test simulated loss-of-coolant accident (LOCA) conditions in a pressurized water reactor (LOFT Reactor, Idaho National Laboratory). A laser beam was selected as the optimum welding process because of the extremely high energy input per unit volume that can be achieved allowing local fusion of a small area irrespective of the difference in material thickness to be joined. A commercial pulsed laser and energy control system was installed along with specialized welding fixtures. Laser room facility requirements and tolerances were established. Performance qualifications, and detailed welding procedures were also developed. Product performance tests were conducted to assure that engineering design requirements could be met on a production basis

  12. Quantitative imaging analysis of posterior fossa ependymoma location in children.

    Science.gov (United States)

    Sabin, Noah D; Merchant, Thomas E; Li, Xingyu; Li, Yimei; Klimo, Paul; Boop, Frederick A; Ellison, David W; Ogg, Robert J

    2016-08-01

    Imaging descriptions of posterior fossa ependymoma in children have focused on magnetic resonance imaging (MRI) signal and local anatomic relationships with imaging location only recently used to classify these neoplasms. We developed a quantitative method for analyzing the location of ependymoma in the posterior fossa, tested its effectiveness in distinguishing groups of tumors, and examined potential associations of distinct tumor groups with treatment and prognostic factors. Pre-operative MRI examinations of the brain for 38 children with histopathologically proven posterior fossa ependymoma were analyzed. Tumor margin contours and anatomic landmarks were manually marked and used to calculate the centroid of each tumor. Landmarks were used to calculate a transformation to align, scale, and rotate each patient's image coordinates to a common coordinate space. Hierarchical cluster analysis of the location and morphological variables was performed to detect multivariate patterns in tumor characteristics. The ependymomas were also characterized as "central" or "lateral" based on published radiological criteria. Therapeutic details and demographic, recurrence, and survival information were obtained from medical records and analyzed with the tumor location and morphology to identify prognostic tumor characteristics. Cluster analysis yielded two distinct tumor groups based on centroid location The cluster groups were associated with differences in PFS (p = .044), "central" vs. "lateral" radiological designation (p = .035), and marginally associated with multiple operative interventions (p = .064). Posterior fossa ependymoma can be objectively classified based on quantitative analysis of tumor location, and these classifications are associated with prognostic and treatment factors.

  13. Central nervous system tumors: Radiologic pathologic correlation and diagnostic approach

    Directory of Open Access Journals (Sweden)

    Ishita Pant

    2015-01-01

    Full Text Available Objective: This study was conducted to formulate location-wise radiologic diagnostic algorithms and assess their concordance with the final histopathological diagnosis so as to evaluate their utility in a rural setting where only basic facilities are available. Materials and Methods: A retrospective analysis to assess the concordance of radiology (primarily MRI with final histopathology report was done. Based on the most common incidence of tumor location and basic radiology findings, diagnostic algorithms were prepared. Results: For supratentorial intraaxial parenchymal location concordance was seen in all high-grade astrocytomas, low- and high-grade oligodendrogliomas, metastatic tumors, primitive neuroectodermal tumors, high-grade ependymomas, neuronal and mixed neuro-glial tumors and tumors of hematopoietic system. Lowest concordance was seen in low-grade astrocytomas. In the supratentorial intraaxial ventricular location, agreement was observed in choroid plexus tumors, ependymomas, low-grade astrocytomas and meningiomas; in the supratentorial extraaxial location, except for the lack of concordance in the only case of metastatic tumor, concordance was observed in meningeal tumors, tumors of the sellar region, tumors of cranial and paraspinal nerves; the infratentorial intraaxial parenchymal location showed agreement in low- as well as high-grade astrocytomas, metastatic tumors, high-grade ependymoma, embryonal tumors and hematopoietic tumors; in the infratentorial intraaxial ventricular location, except for the lack of concordance in one case of low-grade astrocytoma and two cases of medulloblastomas, agreement was observed in low- and high-grade ependymoma; infratentorial extraaxial tumors showed complete agreement in all tumors of cranial and paraspinal nerves, meningiomas, and hematopoietic tumors. Conclusion: A location-based approach to central nervous system (CNS tumors is helpful in establishing an appropriate differential diagnosis.

  14. Psychological consideration in patients with cerebral gliomas candidates for intra-operative radiation therapy based on tumor location.

    Science.gov (United States)

    Seddighi, Afsoun; Akbari, Mohammad Esmaeil; Seddighi, Amir Saied; Nikouei, Amir

    2017-01-01

    Intra-operative Radiation Therapy (IORT) is gaining popularity as an adjuvant option to surgical resection, in treatment of glioblastoma multiforme (GBM) for increasing survival rate, which a highly aggressive cerebral tumor with poor prognosis. Τhe authors plan to investigate the effects of IORT combined with surgical resection on the psychological status of these patients based on tumor location. From December 2013 to February 2017, we have enrolled 109 patients with high grade cerebral gliomas, documented by Magnetic Resonance Spectroscopy (MRS). Patients with previous history of brain surgery or radiation, altered mental status and psychological content and patients diagnosed with metastases were excluded. Demographic data, tumor volume based on pre-operative Magnetic Resonance Imaging (MRI) and psychological status were recorded based on Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV) criteria. The remaining 56 patients, were equally randomized into conventional (surgical resection-group A), and trial (surgical resection with IORT-group B) who underwent IORT using the 50kV INTRABEAM® system (Carl Zeiss Meditec AG, Germany). Psychological profiles of both groups were re-evaluated in the 3 rd post-operative month. Group A consisted of 18 males and 10 females with mean age of 54.4 years, while group B consisted of 16 males and 12 females with mean age of 57.8 years. Tumor volumetry revealed mean 81.52cc and 82.8cc for group A and B respectively. (P value 0.14) Patients were classified based on glioma location on pre-operative MRI: a) left parietal lobe (6 in group A, 5 in group B); b) left temporal lobe (7 in group A, 5 in group B); c) right parietal lobe (5 in group A, 6 in group B); d) left fronto-temporal lobe (4 in group A, 6 in group B); e) left parieto-temporal lobe (4 in group A, 5 in group B); and, f) right frontal lobe (2 in group A, 1 in group B). Group B received mean 8.05 Gy radiation for mean 11.2 minutes. Post

  15. The Combined Use of a Gas-Controlled Heat Pipe and a Copper Point to Improve the Calibration of Thermocouples up to 1100 ˚C

    Science.gov (United States)

    Astrua, M.; Iacomini, L.; Battuello, M.

    2008-10-01

    The calibration of platinum-based thermocouples from 420 °C to 1,100 ˚C is currently carried out at INRIM making use of two different apparatus: for temperatures below 930 ˚C, a potassium gas-controlled heat pipe (GCHP) is used, whereas a metal-block furnace is adopted for higher temperatures. The standard uncertainty of the reference temperature obtained in the lower temperature range is almost one order of magnitude better than in the higher temperature range. A sealed copper cell was investigated to see if it could be used to calibrate thermocouples above 930 ˚C with a lower uncertainty than our current procedures allowed. The cell was characterized with Type S and Pt/Pd thermocouples and with an HTPRT. The freezing plateaux were flat within 0.01 ˚C and lasted up to 1 h with a repeatability of 0.02 ˚C. The temperature of the cell was determined with a standard uncertainty of 0.04 ˚C. Hence, the copper cell was found to be superior to the comparator furnace for the calibration of platinum-based thermocouples because of the significant decrease in the uncertainty that it provides. An analysis was also carried out on the calibration of Pt/Pd thermocouples, and it was found that the combined use of the potassium GCHP and the Cu fixed-point cell is adequate to exploit the potential of these sensors in the range from 420 °C to 1,084 °C. A comparison with a fixed-point calibration was also made which gave rise to agreement within 0.07 ˚C between the two approaches.

  16. Influence of Tumor Thrombus Location on the Outcome of External-beam Radiation Therapy in Advanced Hepatocellular Carcinoma With Macrovascular Invasion

    Energy Technology Data Exchange (ETDEWEB)

    Hou Jiazhou [Department of Radiation Oncology, Zhongshan Hospital, Fudan University, Shanghai 200032 (China); Zeng Zhaochong, E-mail: zeng.zhaochong@zs-hospital.sh.cn [Department of Radiation Oncology, Zhongshan Hospital, Fudan University, Shanghai 200032 (China); Zhang Jianying [Department of Radiation Oncology, Zhongshan Hospital, Fudan University, Shanghai 200032 (China); Fan Jia; Zhou Jian [Liver Cancer Institute, Zhongshan Hospital, Fudan University, Shanghai 200032 (China); Zeng Mengsu [Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai 200032 (China)

    2012-10-01

    Purpose: The present study evaluates the influence of portal vein (PV) vs. inferior vena cava (IVC) tumor thrombosis sites on the effectiveness of external-beam radiation therapy (EBRT) in advanced hepatocellular carcinoma (HCC) with macrovascular invasion. Methods and Materials: We retrospectively reviewed 181 HCC patients with PV and/or IVC tumor thrombi who were referred for EBRT at our institution between 2000 and 2009. EBRT was designed to focus on the tumor thrombi with or without primary intrahepatic tumors to deliver a median total conventional dose of 50 Gy (range, 30-60 Gy). Predictors of survival were identified using univariate and multivariate analyses. Results: The median survival was 10.2, 7.4, 17.4, and 8.5 months for patients with PV branch, PV trunk, IVC, and PV plus IVC tumor thrombosis, respectively. Unfavorable pretreatment predictors were associated by multivariate analysis with lower albumin and higher {alpha}-fetoprotein levels, poorer Child-Pugh liver function classification, multiple intrahepatic foci, lymph node metastases, thrombus location, less chance to receive post-EBRT transarterial chemoembolization (TACE) and the two-dimensional EBRT technique. In comparison to patients with PV tumor thrombosis, patients with IVC thrombi had a higher occurrence of solitary intrahepatic lesions (p = 0.027), well-controlled intrahepatic tumors (p < 0.001), and a better response to EBRT (p < 0.001), and they were more likely to receive post-EBRT TACE (p = 0.033). Conclusions: In HCC, patients with IVC thrombus treated with EBRT had a better response rate and longer survival than those with PV thrombus.

  17. Comparative evaluation of corrosion behaviour of type K thin film thermocouple and its bulk counterpart

    International Nuclear Information System (INIS)

    Mukherjee, S.K.; Barhai, P.K.; Srikanth, S.

    2011-01-01

    Highlights: → Anodic vacuum arc deposited chromel and alumel films are more 'noble' in 5% NaCl solution than their respective wires. → Chromel undergoes localised corrosion while alumel shows uniform corrosion. → Virgin samples of chromel-alumel TFTCs exhibit good thermoelectric response. → Their thermoelectric outputs remain largely unaffected when shelved under normal atmospheric conditions. → After 288 h of exposure in salt spray environment, their thermoelectric outputs show noticeable change due to size effects. - Abstract: This paper investigates the corrosion behaviour of type K thermoelements and their thin films, and compares the performance of chromel-alumel thin film thermocouple with its wire counterpart before and after exposure to 5% NaCl medium. Potentiodynamic polarisation tests reveal that chromel and alumel films are more 'noble' than their respective wires. Alumel corrodes faster when coupled with chromel in films than as wires. Secondary electron micrographs and electrochemical impedance spectroscopy measurements suggest that chromel shows localised corrosion while alumel undergoes uniform corrosion. Corrosion adversely affects the thermocouple output and introduces an uncertainty in the measurement.

  18. Tumor-targeted delivery of IL-2 by NKG2D leads to accumulation of antigen-specific CD8+ T cells in the tumor loci and enhanced anti-tumor effects.

    Directory of Open Access Journals (Sweden)

    Tae Heung Kang

    Full Text Available Interleukin-2 (IL-2 has been shown to promote tumor-specific T-cell proliferation and differentiation but systemic administration of IL-2 results in significant toxicity. Therefore, a strategy that can specifically deliver IL-2 to the tumor location may alleviate concerns of toxicity. Because NKG2D ligands have been shown to be highly expressed in many cancer cells but not in healthy cells, we reason that a chimeric protein consisting of NKG2D linked to IL-2 will lead to the specific targeting of IL-2 to the tumor location. Therefore, we created chimeric proteins consisting of NKG2D linked to Gaussia luciferase (GLuc; a marker protein or IL-2 to form NKG2D-Fc-GLuc and NKG2D-Fc-IL2, respectively. We demonstrated that NKG2D linked to GLuc was able to deliver GLuc to the tumor location in vivo. Furthermore, we showed that TC-1 tumor-bearing mice intramuscularly injected with DNA encoding NKG2D-Fc-IL2, followed by electroporation, exhibited an increased number of luciferase-expressing E7-specific CD8+ T cells at the tumor location. More importantly, treatment with the DNA construct encoding NKG2D-Fc-IL2 significantly enhanced the therapeutic anti-tumor effects generated by intradermal vaccination with therapeutic HPV DNA in tumor-bearing mice. Therefore, by linking NKG2D to IL2, we are able to specifically deliver IL-2 to the tumor location, enhancing antigen-specific T-cell immune response and controlling tumor growth. Our approach represents a platform technology to specifically deliver proteins of interest to tumor loci.

  19. A Simple Test to Evaluate the Calibration Stability and Accuracy of Infrared Thermocouple Sensors

    OpenAIRE

    Pinnock, Derek R.; Bugbee, Bruce

    2002-01-01

    Accurately measuring surface temperature is not difficult when the surface, the sensor, and air temperatures are similar, but it is challenging when the surface temperature is significantly different than air and sensor temperatures. We tested three Infrared Thermocouple sensors (IRT’s) that had been used for two years in a greenhouse environment. The importance of the correction for sensor body temperature was also examined.

  20. An Explicit Approach Toward Modeling Thermo-Coupled Deformation Behaviors of SMPs

    Directory of Open Access Journals (Sweden)

    Hao Li

    2017-03-01

    Full Text Available A new elastoplastic J 2 -flow models with thermal effects is proposed toward simulating thermo-coupled finite deformation behaviors of shape memory polymers. In this new model, an elastic potential evolving with development of plastic flow is incorporated to characterize the stress-softening effect at unloading and, moreover, thermo-induced plastic flow is introduced to represent the strain recovery effect at heating. It is shown that any given test data for both effects may be accurately simulated by means of direct and explicit procedures. Numerical examples for model predictions compare well with test data in literature.

  1. Development of Mechanical Sealing and Laser Welding Technology to Instrument Thermocouple for Nuclear Fuel Test Rod

    Energy Technology Data Exchange (ETDEWEB)

    Joung, Chang-Young; Ahn, Sung-Ho; Hong, Jin-Tae; Kim, Ka-Hye; Huh, Sung-Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    Zircaloy-4 of the nuclear fuel test rod, AISI 316L of the mechanical sealing parts, and the MI (mineral insulated) cable at a thermocouple instrumentation are hetero-metals, and are difficult to weld to dissimilar materials. Therefore, a mechanical sealing method to instrument the thermocouple should be conducted using two kinds of sealing process as follows: One is a mechanical sealing process using Swagelok, which is composed of sealing components that consists of an end-cap, a seal tube, a compression ring and a Swagelok nut. The other is a laser welding process used to join a seal tube, and an MI cable, which are made of the same material. The mechanical sealing process should be sealed up with the mechanical contact compressed by the strength forced between a seal tube and an end-cap, and the laser welding process should be conducted to have no defects on the sealing area between a seal tube and an MI cable. Therefore, the mechanical sealing and laser welding techniques need to be developed to accurately measure the centerline temperature of the nuclear fuel test rod in an experimental reactor. The mechanical sealing and laser welding tests were conducted to develop the thermocouple instrumentation techniques for the nuclear fuel test rod. The optimum torque value of a Swagelok nut to seal the mechanical sealing part between the end-cap and seal tube was established through various torque tests using a torque wrench. The optimum laser welding conditions to seal the welding part between a seal tube and an MI cable were obtained through various welding tests using a laser welding system.

  2. Development of Mechanical Sealing and Laser Welding Technology to Instrument Thermocouple for Nuclear Fuel Test Rod

    International Nuclear Information System (INIS)

    Joung, Chang-Young; Ahn, Sung-Ho; Hong, Jin-Tae; Kim, Ka-Hye; Huh, Sung-Ho

    2015-01-01

    Zircaloy-4 of the nuclear fuel test rod, AISI 316L of the mechanical sealing parts, and the MI (mineral insulated) cable at a thermocouple instrumentation are hetero-metals, and are difficult to weld to dissimilar materials. Therefore, a mechanical sealing method to instrument the thermocouple should be conducted using two kinds of sealing process as follows: One is a mechanical sealing process using Swagelok, which is composed of sealing components that consists of an end-cap, a seal tube, a compression ring and a Swagelok nut. The other is a laser welding process used to join a seal tube, and an MI cable, which are made of the same material. The mechanical sealing process should be sealed up with the mechanical contact compressed by the strength forced between a seal tube and an end-cap, and the laser welding process should be conducted to have no defects on the sealing area between a seal tube and an MI cable. Therefore, the mechanical sealing and laser welding techniques need to be developed to accurately measure the centerline temperature of the nuclear fuel test rod in an experimental reactor. The mechanical sealing and laser welding tests were conducted to develop the thermocouple instrumentation techniques for the nuclear fuel test rod. The optimum torque value of a Swagelok nut to seal the mechanical sealing part between the end-cap and seal tube was established through various torque tests using a torque wrench. The optimum laser welding conditions to seal the welding part between a seal tube and an MI cable were obtained through various welding tests using a laser welding system

  3. External attachment of titanium sheathed thermocouples to zirconium nuclear fuel rods for the loss-of-fluid-test (LOFT) Reactor

    International Nuclear Information System (INIS)

    Welty, R.K.

    1980-01-01

    A welding process to attach titanium sheathed thermocouples to the outside of the zircaloy clad fuel rods has been developed. A laser beam was selected as the optimum welding process because of the extremely high energy input per unit volume that can be achieved allowing local fusion of a small area irrespective of the difference in material thickness to be joined. Irradiation tests showed no degradation of thermocouples or weld structure. Fast thermal cycle and heater rod blowdown reflood tests were made to subject the weldments to high temperatures, high pressure steam, and fast water quench cycles. From the behavior of these tests, it was concluded that the attachment welds would survive a series of reactor safety tests. 2 refs

  4. Nuclear Power Plant Thermocouple Sensor-Fault Detection and Classification Using Deep Learning and Generalized Likelihood Ratio Test

    Science.gov (United States)

    Mandal, Shyamapada; Santhi, B.; Sridhar, S.; Vinolia, K.; Swaminathan, P.

    2017-06-01

    In this paper, an online fault detection and classification method is proposed for thermocouples used in nuclear power plants. In the proposed method, the fault data are detected by the classification method, which classifies the fault data from the normal data. Deep belief network (DBN), a technique for deep learning, is applied to classify the fault data. The DBN has a multilayer feature extraction scheme, which is highly sensitive to a small variation of data. Since the classification method is unable to detect the faulty sensor; therefore, a technique is proposed to identify the faulty sensor from the fault data. Finally, the composite statistical hypothesis test, namely generalized likelihood ratio test, is applied to compute the fault pattern of the faulty sensor signal based on the magnitude of the fault. The performance of the proposed method is validated by field data obtained from thermocouple sensors of the fast breeder test reactor.

  5. Tumor Estromal Gastrintestinal de Localização Esofágica: Relato de Caso/ Gastrointestinal Stromal Tumor Location Esophageal: Case Report

    Directory of Open Access Journals (Sweden)

    Daniele Ribeiro Matsumoto

    2013-06-01

    Full Text Available Introdução: Os tumores estromais gastrintestinais (GIST são considerados as neoplasias mesenquimatosas mais comuns do trato gastrintestinal (TGI. São derivados das células intersticiais de Cajal, localizadas ao nível do plexo mioentérico e responsáveis pela motilidade gastrintestinal. Podem se originar em qualquer região do TGI, sendo apenas 5% provenientes do esôfago. Casuística: Foi relatado um caso de GIST de localização esofágica em um paciente que iniciou quadro de disfagia para alimentos sólidos e odinofagia, de caráter intermitente, acompanhado de náuseas e vômitos. Foram realizadas Seriografia contrastada de esôfago, Endoscopia Digestiva Alta, Tomografia Computadorizada de Abdome, o resultado histopatológico da biópsia da lesão foi inconclusivo e o diagnóstico foi confirmado pela imunohistoquímica que expressou CD117 (KIT pelas células neoplásicas. O serviço de oncologia de referência orientou a realização de cirurgia para ressecção tumoral, porém o paciente optou pela utilização do Mesilato de Imatinib (MI, tendo apresentado melhora progressiva do quadro clínico inicial. Discussão: O tratamento padrão para pacientes com GIST não metastático é a ressecção completa da lesão, pois oferece a maior chance de cura. Entretanto, o paciente optou somente pelo tratamento com o MI. Conclusão: Concluímos que o GIST deve ser considerado nas lesões exofíticas esofágicas e que o tratamento somente com o MI pode ser considerado, mesmo sabendo que o tratamento preconizado nestes casos é a ressecção cirúrgica, associada ao MI como terapia adjuvante, com melhora da sobrevida. Introduction: The gastrointestinal stromal tumor (GIST considered the most common mesenchymal neoplasm of the gastrointestinal tract (GIT. It is derived from interstitial cells of Cajal, located at the myenteric plexus and responsible for gastrointestinal motility. It can originate anywhere in the GI tract, and only 5% come from

  6. Multiparametric classification links tumor microenvironments with tumor cell phenotype.

    Directory of Open Access Journals (Sweden)

    Bojana Gligorijevic

    2014-11-01

    Full Text Available While it has been established that a number of microenvironment components can affect the likelihood of metastasis, the link between microenvironment and tumor cell phenotypes is poorly understood. Here we have examined microenvironment control over two different tumor cell motility phenotypes required for metastasis. By high-resolution multiphoton microscopy of mammary carcinoma in mice, we detected two phenotypes of motile tumor cells, different in locomotion speed. Only slower tumor cells exhibited protrusions with molecular, morphological, and functional characteristics associated with invadopodia. Each region in the primary tumor exhibited either fast- or slow-locomotion. To understand how the tumor microenvironment controls invadopodium formation and tumor cell locomotion, we systematically analyzed components of the microenvironment previously associated with cell invasion and migration. No single microenvironmental property was able to predict the locations of tumor cell phenotypes in the tumor if used in isolation or combined linearly. To solve this, we utilized the support vector machine (SVM algorithm to classify phenotypes in a nonlinear fashion. This approach identified conditions that promoted either motility phenotype. We then demonstrated that varying one of the conditions may change tumor cell behavior only in a context-dependent manner. In addition, to establish the link between phenotypes and cell fates, we photoconverted and monitored the fate of tumor cells in different microenvironments, finding that only tumor cells in the invadopodium-rich microenvironments degraded extracellular matrix (ECM and disseminated. The number of invadopodia positively correlated with degradation, while the inhibiting metalloproteases eliminated degradation and lung metastasis, consistent with a direct link among invadopodia, ECM degradation, and metastasis. We have detected and characterized two phenotypes of motile tumor cells in vivo, which

  7. Design and research of seal structure for thermocouple column assembly

    International Nuclear Information System (INIS)

    Rao Qiqi; Li Na; Zhao Wei; Ma Zhigang

    2015-01-01

    The new seal structure was designed to satisfy the function of thermocouple column assembly and the reactor structure. This seal structure uses the packing graphite ring and adopts the self-sealing principle. Cone angle is brought to the seal face of seal structure which is conveniently to assembly and disassembly. After the sealing principle analysis and stress calculation of graphite ring which adopt the cone angle, the cone angle increases the radial force of seal structure and improves the seal effect. The stress analysis result shows the seal structure strength satisfies the regulation requirement. The cold and hot function test results shows the sealing effect is good, and the design requirement is satisfied. (authors)

  8. LOFT ECC Pitot Tube and Thermocouple Rake Penetration thermal analysis

    International Nuclear Information System (INIS)

    Tolan, B.J.

    1977-01-01

    A thermal analysis of the LOFT ECC Pitot Tube and Thermocouple Rake Penetration was performed using COUPLE, a two-dimensional finite element computer code. Four transients which conservatively cover all transients the rake will be exposed to were included in this analysis in order to comply with the ASME Code Section III requirements. The transients conservatively cover hot and cold leg operation, and nuclear and nonnuclear operation. The four transients include the LOCE with ECC injection transient, the single control rod drop transient, the scram transient, and the heatup with 0 to 100% load change transient. Temperature distributions in the rake were obtained for each of the four transients and several plots of node temperatures vs. time are given

  9. Tumor immunology

    International Nuclear Information System (INIS)

    Otter, W. den

    1987-01-01

    Tumor immunology, the use of immunological techniques for tumor diagnosis and approaches to immunotherapy of cancer are topics covered in this multi-author volume. Part A, 'Tumor Immunology', deals with present views on tumor-associated antigens, the initiation of immune reactions of tumor cells, effector cell killing, tumor cells and suppression of antitumor immunity, and one chapter dealing with the application of mathematical models in tumor immunology. Part B, 'Tumor Diagnosis and Imaging', concerns the use of markers to locate the tumor in vivo, for the histological diagnosis, and for the monitoring of tumor growth. In Part C, 'Immunotherapy', various experimental approaches to immunotherapy are described, such as the use of monoclonal antibodies to target drugs, the use of interleukin-2 and the use of drugs inhibiting suppression. In the final section, the evaluation, a pathologist and a clinician evaluate the possibilities and limitations of tumor immunology and the extent to which it is useful for diagnosis and therapy. refs.; figs.; tabs

  10. Hospital-based colorectal cancer survival trend of different tumor locations from 1960s to 2000s.

    Directory of Open Access Journals (Sweden)

    Yu-Jing Fang

    Full Text Available BACKGROUND: Our aim is to explore the trend of association between the survival rates of colorectal cancer (CRC and the different clinical characteristics in patients registered from 1960s to 2000s. We hypothesized that the survival rate of CRC increases over time and varies according to anatomic subsites. METHODS: Information from a total of 4558 stage T(1-4N(1-2M0 CRC patients registered from 1960s to 2008 were analyzed. The association of CRC overall survival with age, gender, tumor locations, time, histopathology types, pathology grades, no. of examined lymph nodes, the T stage, and the N stage was analyzed. The assessment of the influence of prognostic factors on patient survival was performed using Cox's proportional hazard regression models. RESULTS: From 1960 to 2008, the studied CRC patients included 2625 (57.6% and 1933 (42.4% males and females, respectively. These included 1896 (41.6% colon cancers, and 2662 (58.4% rectum cancers. The 5-year survival rate was 49%, 58%, 58%, 70%, and 77% for the time duration of 1960s, 1970s, 1980s, 1990s and 2000s, respectively. An increased 5-year survival rate was observed in the colon cancer and rectum cancer patients. Patients older than 60 years of age were more likely to develop colonic cancer (sigmoid than rectum cancer (49.2% vs. 39.9%. The Cox regression model showed that only rectum cancer survival was related to time duration. CONCLUSION: The overall survival and 5-year survival rates showed an increase from the 1960s to 2000s. There is a trend of rightward shift of tumor location in CRC patients.

  11. Evaluation of primary neck tumors by computed tomography

    International Nuclear Information System (INIS)

    Suzuki, Keiko

    1983-01-01

    Application of computed tomography (CT) to neck tumors has received little attention. 40 CT scans of primary neck tumors were reviewed, and CT was proved to be extremely useful in the diagnosis and definition of extension of primary neck tumors. In the carotid triangle and sternocleidomastoid region 2nd branchial cysts, cystic hygromas and tuberculous lymphadenitis are included in the differential diagnosis of cystic tumors. In the carotid triangle markedly enhanced solid tumors must be paragangliomas, i.e. carotid body tumors, if they are located posteromedial to the carotid artery. And moderately enhanced tumors are neurilemmomas arising from sympathetic or vagus nerve. It is easy to define enlarged deep jugular lymph nodes because they are located lateral to the carotid artery. In the supraclavicular fossa enlarged lymph nodes can be differentiated from neurilemmomas of branchial plexus because enlarged lymph nodes are located anterior to subclavian vessels or anterior scalene muscle and branchial neurilemmomas are located superoposterior to them. (author)

  12. Clinical introduction of Monte Carlo treatment planning: A different prescription dose for non-small cell lung cancer according to tumor location and size

    International Nuclear Information System (INIS)

    Voort van Zyp, Noelle C. van der; Hoogeman, Mischa S.; Water, Steven van de; Levendag, Peter C.; Holt, Bronno van der; Heijmen, Ben J.M.; Nuyttens, Joost J.

    2010-01-01

    Purpose: To provide a prescription dose for Monte Carlo (MC) treatment planning in patients with non-small-cell lung cancer according to tumor size and location. Methods: Fifty-three stereotactic radiotherapy plans designed using the equivalent path-length (EPL) algorithm were re-calculated using MC. Plans were compared by the minimum dose to 95% of the PTV (D95), the heterogeneity index (HI) and the mean dose to organs at risk (OARs). Based on changes in D95, the prescription dose was converted from EPL to MC. Based on changes in HI, we examined the feasibility of MC prescription to plans re-calculated but not re-optimized with MC. Results: The MC fraction dose for peripheral tumors is 16-18 Gy depending on tumor size. For central tumors the MC dose was reduced less than for peripheral tumors. The HI decreased on average by 4-9% in peripheral tumors and 3-5% in central tumors. The mean dose to OARs was lower for MC than EPL, and correlated strongly (R 2 = 0.98-0.99). Conclusion: For the conversion from EPL to MC we recommend a separate prescription dose according to tumor size. MC optimization is not required if a HI ≥ 70% is accepted. Dose constraints to OARs can be easily converted due to the high EPL-MC correlation.

  13. Internal attachment of laser beam welded stainless steel sheathed thermocouples into stainless steel upper end caps in nuclear fuel rods for the LOFT Reactor

    International Nuclear Information System (INIS)

    Welty, R.K.; Reid, R.D.

    1980-01-01

    The Exxon Nuclear Company, Inc., acting as a subcontractor to EG and G Idaho Inc., Idaho National Engineering Laboratory, Idaho Falls, Idaho, conducted a laser beam welding study to attach internal stainless steel thermocouples into stainless steel upper end caps in nuclear fuel rods. The objective of this study was to determine the feasibility of laser welding a single 0.063 inch diameter stainless steel (304) sheathed thermocouple into a stainless steel (316) upper end cap for nuclear fuel rods. A laser beam was selected because of the extremely high energy input in unit volume that can be achieved allowing local fusion of a small area irrespective of the difference in material thickness to be joined. A special weld fixture was designed and fabricated to hold the end cap and the thermocouple with angular and rotational adjustment under the laser beam. A commercial pulsed laser and energy control system was used to make the welds

  14. Procedural difficulty differences according to tumor location do not compromise the clinical outcome of laparoscopic complete mesocolic excision for colon cancer: a retrospective analysis.

    Science.gov (United States)

    Kim, Min Ki; Lee, In Kyu; Kye, Bong-Hyeon; Kim, Jun-Gi

    2017-09-08

    Laparoscopic colectomy procedures and their corresponding difficulty levels may vary depending on the tumor location within the colon, and a laparoscopic complete mesocolic excision (CME) with central vascular ligation (CVL) would require more proficiency than a conventional laparoscopic colectomy. We aimed to report our laparoscopic CME with CVL data and to investigate the clinical outcome differences of laparoscopic CME with CVL by various tumor sub-site locations. Prospectively collected clinical data of consecutive patients who received laparoscopic colectomy for primary colon cancer between April 1995 and December 2010 from single surgeon were retrospectively reviewed. All of the included surgery was performed on the basis of CME with CVL principle with no-touch isolation technique. Data were analyzed and compared among three groups; patients who received right or extended right hemicolectomy (group A, n = 142), transverse colectomy or left or extended left hemicolectomy (group B, n = 59), and sigmoidectomy or anterior resection (group C, n = 210). Female patients were more common in group A (53.5% vs. 37.3% vs. 39.5%, p = 0.020). Other baseline characteristics were comparable. Operative time was shorter in group C than the other groups (309.0 ± 74.7 vs. 324.3 ± 89.1 vs. 280.1 ± 93.1 min, p = 0.000). There was no significant difference among groups in perioperative complication and patient recovery. Five-year overall survival, disease-free survival and local recurrence rate showed no difference for a median follow up period of 73 (1-120) months. In conclusion, laparoscopic tumor-specific CME and CVL for colon cancer can be performed with comparable short- and long-term outcomes regardless of tumor sub-site location except for the operative time.

  15. Germ Cell Tumor Located in the Midline of the Anterior Neck

    OpenAIRE

    Tatyana PIRDOPSKA; Ivan TERZIEV; Sv. HRISTOVA; W. MLADENOVSKY; R. PETKOV

    2011-01-01

    Primary germ cell tumors involving midline of the anterior neck are extremely rare. Here we report a 68-year-old male who was operated due to a mass lesion in the anterior neck with infiltration of the isthmus of the thyroid gland. Histopathological examination revealed a germ cell tumor with extragonadal localization in the anterior neck infiltrating the isthmus of the thyroid gland.

  16. SU-F-J-119: Pilot Study On the Location-Based Lung Motion Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Lee, TK [Procure Proton Therapy Center, Oklahoma City, OK (United States); Ewald, A [McLaren Cancer Institute, Flint, MI (United States)

    2016-06-15

    Purpose: In most of lung treatment cases with various radiotherapy beam modalities, 4DCT images are obtained in order to define ITV. ITV is defined with the signal from motion monitoring system, e.g. RPM. However, the signal is not consistent with tumor motion because it varies with location, its size, age, gender, etc. In the present study, the location-based motion assessment is presented. Methods: 4DCT images of 70 patients were reviewed: 28-left-lung and 42-right-lung patients; 36-female and 34-male patients; the age range of 51.2–89.9; tumor-size range of 0.75–9.50cm with 25% of these adherent to bony-anatomy. Philips Big-Bore Simulation CT and RPM systems were used. The study was performed as follows. First, RPM signal and tumor motion in superior-inferior direction was compared. Second, the tumor size and its motion amplitude in all directions were measured at multiple locations. Third, the average tumor motion was calculated to assess general motion amplitudes at various locations. Results: RPM amplitude is not consistent with lung tumor motion amplitude. The tumors of similar sizes at similar location present various motion amplitude up to 1.1cm difference, but in average, the standard deviation was <0.5cm. Almost regardless of tumor sizes, the tumor motion was greatest at lower lobe location (>=1.0cm), and the smallest at upper lobe location and when adherent to bony-anatomy (<=0.5cm). Conclusion: The tumor size affects the motion amplitude less than does the tumor location. However, as the study results indicate that tumor motion has noticeable variation and so further study with more patient cases is needed. Also, for the same patient, the RPM signal presents instability of breathing, and clinically the patient with the instability of RPM breathing of <=10% is selected for respiratory-gated radiotherapy and ∼25% of patients under current study was treated. Patient-specific motion-uncertainty margins are considered to be added following further

  17. Diagnostic Modalities for FGF23-Producing Tumors in Patients with Tumor-Induced Osteomalacia

    Directory of Open Access Journals (Sweden)

    Seiji Fukumoto

    2014-06-01

    Full Text Available Fibroblast growth factor 23 (FGF23 is a hormone that is produced by osteocytes and regulates phosphate and vitamin D metabolism through binding to the Klotho-FGF receptor complex. Excessive actions of FGF23 cause several kinds of hypophosphatemic rickets/osteomalacia. Tumor-induced rickets/osteomalacia (TIO is a paraneoplastic syndrome caused by overproduction of FGF23 from the responsible tumors. Because TIO is cured by complete resection of the causative tumors, it is of great clinical importance to locate these tumors. Several imaging methods including skeletal survey by magnetic resonance imaging and octreotide scintigraphy have been used to identify the tumors that cause TIO. However, none of these imaging studies indicate that the detected tumors are actually producing FGF23. Recently, systemic venous sampling was conducted for locating FGF23-producing tumor in suspected patients with TIO and demonstrated that this test might be beneficial to a subset of patient. Further studies with more patients are necessary to establish the clinical utility of venous sampling in patients with TIO.

  18. Spin Lattice Relaxation EPR pO2 Images May Direct the Location of Radiation Tumor Boosts to Enhance Tumor Cure.

    Science.gov (United States)

    Epel, Boris; Krzykawska-Serda, Martyna; Tormyshev, Victor; Maggio, Matthew C; Barth, Eugene D; Pelizzari, Charles A; Halpern, Howard J

    2017-12-01

    Radiation treatment success and high tumor oxygenation and success have been known to be highly correlated. This suggests that radiation therapy guided by images of tumor regions with low oxygenation, oxygen-guided radiation therapy (OGRT) may be a promising enhancement of cancer radiation treatment. Before applying the technique to human subjects, OGRT needs to be tested in animals, most easily in rodents. Electron paramagnetic resonance imaging provides quantitative maps of tissue and tumor oxygen in rodents with 1 mm spatial resolution and 1 torr pO 2 resolution at low oxygen levels. The difficulty of using mouse models is their small size and that of their tumors. To overcome this we used XRAD225Cx micro-CT/ therapy system and 3D printed conformal blocks. Radiation is delivered first to a uniform 15% tumor control dose for the whole tumor and then a boost dose to either hypoxic tumor regions or equal volumes of well oxygenated tumor. Delivery of the booster dose used a multiple beam angles to deliver radiation beams whose shape conforms to that of all hypoxic regions or fully avoids those regions. To treat/avoid all hypoxic regions we used individual radiation blocks 3D-printed from acrylonitrile butadiene styrene polymer infused with tungsten particles fabricated immediately after imaging to determine regions with pO 2 less than 10 torr. Preliminary results demonstrate the efficacy of the radiation treatment with hypoxic boosts with syngeneic FSa fibrosarcoma tumors in the legs of C3H mice.

  19. Investigating Microbial Habitats in Hydrothermal Chimneys using Ti-Thermocouple Arrays: Microbial Diversity

    Science.gov (United States)

    Pagé, A.; Tivey, M. K.; Stakes, D. S.; Bradley, A. M.; Seewald, J. S.; Wheat, C. G.; Reysenbach, A.

    2004-12-01

    In order to examine the changes that occur in the microbial community composition as a deep-sea hydrothermal vent chimney develops, we deployed Ti-thermocouple arrays over high temperature vents at two active sites of the Guaymas Basin Southern Trough. Chimney material that precipitated around the arrays was recovered after 4 and 72 days. Chimney material that precipitated prior to deployment of the arrays was also recovered at one of the sites (Busted Shroom). Culture-independent analysis based on the small subunit rRNA sequence (cloning and DGGE) was used to determine the microbial diversity associated with subsamples of each chimney. The original Busted Shroom chimney (BSO) was dominated by members of the Crenarchaeota Marine Group I, a group of cosmopolitan marine Archaea, ɛ -Proteobacteria, and γ -Proteobacteria, two divisions of Bacteria that are common to deep-sea vents. The 4 days old Busted Shroom chimney (BSD1) was dominated by members of the Methanocaldococcaceae, hyperthermophilic methanogens, and the 72 days old chimney (BSD2) by members of the Methanosarcinaceae, mesophilic and thermophilic methanogens. At the second site, Toadstool, the 72 days old chimney material that had precipitated around the array (TS) revealed the dominance of sequences from uncultured marine Archaea, the DHVE group I and II, and from the ɛ -Proteobacteria. Additionally, sequences belonging to the Methanocaldococcaceae and Desulfurococcaceae were recovered next to thermocouples that were at temperatures of 109° C (at Busted Shroom) and 116° C (at Toadstool), respectively. These temperatures are higher than the upper limit for growth of cultured representatives from each family.

  20. Primary malignant peripheral nerve sheath tumor at unusual location

    Directory of Open Access Journals (Sweden)

    Souvagya Panigrahi

    2013-01-01

    Full Text Available Malignant peripheral nerve sheath tumor (MPNST is a rare soft tissue sarcoma. Most arise in association with major nerve trunks. Their most common anatomical sites are the proximal portions of the upper and lower extremities and the trunk. MPNSTs have rarely been reported in literature to occur in other unusual body parts. We review all such cases reported till now in terms of site of origin, surgical treatment, adjuvant therapy and outcome and shortly describe our experience with two of these cases. Both of our case presented with lump at unusual sites resembling neurofibroma, one at orbitotemporal area and other in the paraspinal region with characteristic feature of neurofibroma with the exception that both had very short history of progression. They underwent gross total removal of the tumor with adjuvant radiotherapy postoperatively. At 6-month follow-up both are doing well with no evidence of recurrence.

  1. Pituitary gland tumors

    International Nuclear Information System (INIS)

    Jesser, J.; Schlamp, K.; Bendszus, M.

    2014-01-01

    This article gives an overview of the most common tumors of the pituitary gland and the differential diagnostics with special emphasis on radiological diagnostic criteria. A selective search of the literature in PubMed was carried out. Pituitary adenomas constitute 10-15 % of all intracranial tumors and are the most common tumors of the sellar region. Tumors smaller than 1 cm in diameter are called microadenomas while those larger than 1 cm in diameter are called macroadenomas. Approximately 65 % of pituitary gland adenomas secrete hormones whereby approximately 50 % secrete prolactin, 10 % secrete growth hormone (somatotropin) and 6 % secrete corticotropin. Other tumors located in the sella turcica can also cause endocrinological symptoms, such as an oversecretion of pituitary hormone or pituitary insufficiency by impinging on the pituitary gland or its stalk. When tumors spread into the space cranial to the sella turcica, they can impinge on the optic chiasm and cause visual disorders. A common differential diagnosis of a sellar tumor is a craniopharyngeoma. In children up to 10 % of all intracranial tumors are craniopharyngeomas. Other differential diagnoses for sellar tumors are metastases, meningiomas, epidermoids and in rare cases astrocytomas, germinomas or Rathke cleft cysts As these tumors are located in an anatomically complex region of the skull base and are often very small, a highly focused imaging protocol is required. The currently favored modality is magnetic resonance imaging (MRI) with the administration of a contrast agent. The sellar region should be mapped in thin slices. In cases of suspected microadenoma the imaging protocol should also contain a sequence with dynamic contrast administration in order to assess the specific enhancement characteristics of the tumor and the pituitary gland. (orig.) [de

  2. [Pituitary gland tumors].

    Science.gov (United States)

    Jesser, J; Schlamp, K; Bendszus, M

    2014-10-01

    This article gives an overview of the most common tumors of the pituitary gland and the differential diagnostics with special emphasis on radiological diagnostic criteria. A selective search of the literature in PubMed was carried out. Pituitary adenomas constitute 10-15% of all intracranial tumors and are the most common tumors of the sellar region. Tumors smaller than 1 cm in diameter are called microadenomas while those larger than 1 cm in diameter are called macroadenomas. Approximately 65% of pituitary gland adenomas secrete hormones whereby approximately 50% secrete prolactin, 10% secrete growth hormone (somatotropin) and 6% secrete corticotropin. Other tumors located in the sella turcica can also cause endocrinological symptoms, such as an oversecretion of pituitary hormone or pituitary insufficiency by impinging on the pituitary gland or its stalk. When tumors spread into the space cranial to the sella turcica, they can impinge on the optic chiasm and cause visual disorders. A common differential diagnosis of a sellar tumor is a craniopharyngeoma. In children up to 10% of all intracranial tumors are craniopharyngeomas. Other differential diagnoses for sellar tumors are metastases, meningiomas, epidermoids and in rare cases astrocytomas, germinomas or Rathke cleft cysts As these tumors are located in an anatomically complex region of the skull base and are often very small, a highly focused imaging protocol is required. The currently favored modality is magnetic resonance imaging (MRI) with the administration of a contrast agent. The sellar region should be mapped in thin slices. In cases of suspected microadenoma the imaging protocol should also contain a sequence with dynamic contrast administration in order to assess the specific enhancement characteristics of the tumor and the pituitary gland.

  3. Spinal tumors

    International Nuclear Information System (INIS)

    Goethem, J.W.M. van; Hauwe, L. van den; Oezsarlak, Oe.; Schepper, A.M.A. de; Parizel, P.M.

    2004-01-01

    Spinal tumors are uncommon lesions but may cause significant morbidity in terms of limb dysfunction. In establishing the differential diagnosis for a spinal lesion, location is the most important feature, but the clinical presentation and the patient's age and gender are also important. Magnetic resonance (MR) imaging plays a central role in the imaging of spinal tumors, easily allowing tumors to be classified as extradural, intradural-extramedullary or intramedullary, which is very useful in tumor characterization. In the evaluation of lesions of the osseous spine both computed tomography (CT) and MR are important. We describe the most common spinal tumors in detail. In general, extradural lesions are the most common with metastasis being the most frequent. Intradural tumors are rare, and the majority is extramedullary, with meningiomas and nerve sheath tumors being the most frequent. Intramedullary tumors are uncommon spinal tumors. Astrocytomas and ependymomas comprise the majority of the intramedullary tumors. The most important tumors are documented with appropriate high quality CT or MR images and the characteristics of these tumors are also summarized in a comprehensive table. Finally we illustrate the use of the new World Health Organization (WHO) classification of neoplasms affecting the central nervous system

  4. Tumor-induced osteomalacia

    Science.gov (United States)

    Chong, William H; Molinolo, Alfredo A; Chen, Clara C; Collins, Michael T

    2012-01-01

    Tumor-induced osteomalacia (TIO) is a rare and fascinating paraneoplastic syndrome in which patients present with bone pain, fractures, and muscle weakness. The cause is high blood levels of the recently identified phosphate and vitamin D-regulating hormone, fibroblast growth factor 23 (FGF23). In TIO, FGF23 is secreted by mesenchymal tumors that are usually benign, but are typically very small and difficult to locate. FGF23 acts primarily at the renal tubule and impairs phosphate reabsorption and 1α-hydroxylation of 25-hydroxyvitamin D, leading to hypophosphatemia and low levels of 1,25-dihydroxy vitamin D. A step-wise approach utilizing functional imaging (F-18 fluorodeoxyglucose positron emission tomography and octreotide scintigraphy) followed by anatomical imaging (computed tomography and/or magnetic resonance imaging), and, if needed, selective venous sampling with measurement of FGF23 is usually successful in locating the tumors. For tumors that cannot be located, medical treatment with phosphate supplements and active vitamin D (calcitriol or alphacalcidiol) is usually successful; however, the medical regimen can be cumbersome and associated with complications. This review summarizes the current understanding of the pathophysiology of the disease and provides guidance in evaluating and treating these patients. Novel imaging modalities and medical treatments, which hold promise for the future, are also reviewed. PMID:21490240

  5. Low-noise audio amplifiers and preamplifier for use with intrinsic thermocouples

    International Nuclear Information System (INIS)

    Langner, G.C.; Sachs, R.D.; Stewart, F.L.

    1979-03-01

    Two simple, low-noise audio amplifiers and one low-noise preamplifier for use with intrinsic thermocouples were designed, built, and tested. The amplifiers and the preamplifier have different front end designs. One amplifier uses ultralow-noise operational amplifiers; the other amplifier uses a hybrid component. The preamplifier uses ultralow-noise discrete components. The amplifiers' equivalent noise inputs, at maximum gain, are 4.09 nV and 50 nV; the preamplifier's input is 4.05 μV. Their bandwidths are 15 600 Hz, 550 Hz, and 174 kHz, respectively. the amplifiers' equivalent noise inputs were measured from approx. 0 to 100 Hz, whereas the preamplifier's equivalent noise input was measured from approx. 0 to 174 kHz

  6. Brainstem tumors: Current management and future directions

    Directory of Open Access Journals (Sweden)

    Pablo F Recinos

    2012-01-01

    Full Text Available Tumors arising in the brainstem comprise 10-20% of all pediatric central nervous system (CNS tumors and account for a small percentage in adults. The prognosis for these tumors was considered uniformly poor prior to the era of modern neuroimaging and the location was fraught with disaster being considered a ′no man′s land′ for neurosurgeons. Following the introduction of advanced imaging modalities and neurophysiological monitoring, striking progress has occurred in the management of these lesions. Brainstem tumors are presently classified based on their anatomic location, focality, and histopathology. This article reviews the current classification of brainstem tumors, current management options, and future directions in the treatment for these rare tumors.

  7. Impact of tumor extent and location on treatment outcome in patients with stage III non-small cell lung cancer treated with radiation therapy

    International Nuclear Information System (INIS)

    Hayakawa, Kazushige; Mitsuhashi, Norio; Saito, Yoshihiro

    1996-01-01

    The results of treatment of 141 patients with stage III non-small cell lung cancer (NSCLC) who received definitive radiation therapy at Gunma University Hospital between 1976 and 1989 were retrospectively analyzed. Radiation was given with standard fractionation for a planned prophylactic dose of 40 Gy over 4 weeks and a definitive dose of 60 Gy over 6 weeks or more. The two- and five-year survival rates were 27% and 12% for stage IIIA, and 18% and 8% for stage IIIB, respectively (P=0.052). By univariate analysis, a primary tumor less than 5 cm in diameter was also an important predictor of survival (P=0.008). As for tumor location, the patients with primary tumors in the upper lobes or the superior segment of the lower lobes of the lung lived longer than those with primary tumors at any other site (P=0.032). Patients with epidermoid carcinoma had a higher survival rate at 5 years than those with other histologic types (14% vs 3%, P=0.074). Multivariate analysis showed that among tumor characteristics, the site of the primary tumor, the pattern of tumor spread and N stage were significantly associated with overall survival. Among the patients with stage III NSCLC, those with stage IIIA epidermoid carcinoma in the upper lobe or the superior segment of the lower lobe of the lung were considered to be the most favorable candidates for definitive radiation therapy. (author)

  8. Imaging of childhood inflammatory myofibroblastic tumor

    Energy Technology Data Exchange (ETDEWEB)

    Oguz, Berna; Ozcan, Hatice Nursun; Omay, Burak; Ozgen, Burce; Haliloglu, Mithat [Division of Pediatric Radiology, Hacettepe University Faculty of Medicine, Department of Radiology, Altindag / Sihhiye, Ankara (Turkey)

    2015-10-15

    Inflammatory myofibroblastic tumor is a rare benign neoplasm and most commonly involves the lung but occurs in extrapulmonary locations. To present imaging findings in inflammatory myofibroblastic tumors in children based on a single-centre experience. We retrospectively reviewed CT and MRI findings of children diagnosed with inflammatory myofibroblastic tumor in a single institution. We identified 15 children (range: 1-17 years) with inflammatory myofibroblastic tumor. The tumor was localized to the lung (n = 5), mediastinum (n = 3), trachea (n = 1), bronchus (n = 1), abdomen (n = 2) and orbit (n = 3). All the extraorbital tumors were solid masses with homogeneous or heterogeneous enhancement. Four lung tumors and one posterior mediastinal tumor contained calcification. Local recurrence following surgical removal occurred in two children with invasion of the esophagus and of the left atrium in one. Localized masses were seen in all children with orbital tumour. Two of these had episcleritis and perineuritis; one had episcleritis, tendonitis, perineuritis, myositis and dacryoadenitis. The locations and imaging features of inflammatory myofibroblastic tumors are variable. (orig.)

  9. Virilization caused by an ectopic adrenal tumor located behind the iliopsoas muscle.

    Science.gov (United States)

    Mavroudis, Konstantinos; Aloumanis, Kyriakos; Papapetrou, Peter D; Voros, Dionisios; Spanos, Iraklis

    2007-06-01

    Virilization due to androgen-secreting neoplasms in women is a result of androgen overproduction from benign or malignant tumors that are found in the ovaries or rarely in the adrenal glands. Virilizing tumors that arise from ectopic adrenal tissue are extremely rare. We describe a very rare case of an ectopic androgen-producing adrenal tumor. Case report study. Endocrinology outpatient department of university-affiliated teaching hospital. A 45-year-old woman with symptoms of virilization of abrupt onset and rapid progression, with high serum androgen hormone levels and normal glucocorticoid secretion. Basal hormonal levels, stimulation and suppression tests, imaging techniques, and selective venous sampling. Localization and surgical removal of the source of androgen production. An ectopic mass was detected behind the left iliopsoas muscle. The patient was operated on and an oblong-shaped lesion, weighing 6 g, was removed. Histologically, the tissue was identified to be of adrenal origin. Postoperatively the androgen levels decreased to normal levels. This case illustrates difficulties in detecting and localizing the rare contingence of an ectopic adrenocortical androgen-secreting tumor.

  10. Field installed brazed thermocouple feedthroughs for high vacuum experiments

    International Nuclear Information System (INIS)

    Anderson, P.; Messick, C.

    1983-01-01

    In order to reduce the occurrence of vacuum leaks and to increase the availability of the DIII vacuum vessel for experimental operation, effort was applied to developing a vacuum-tight brazed feedthrough system for sheathed thermocouples, stainless steel sheathed conductor cables and tubes for cooling fluids. This brazed technique is a replacement for elastomer ''O'' ring sealed feedthroughs that have proven vulnerable to leaks caused by thermal cycling, etc. To date, about 200 feedthroughs have been used. Up to 91 were grouped on a single conflat flange mounted in a bulkhead connector configuration which facilitates installation and removal. Investigation was required to select a suitable braze alloy, flux and installation procedure. Braze alloy selection was challenging since the alloy was required to have: 1) Melting temperature in excess of the 250 0 C (482 0 F) bakeout temperature. 2) No high vapor pressure elements. 3) Good wetting properties when used in air with acceptable flux. 4) Good wettability to 300 series stainless steel and inconel

  11. W-1 Sodium Loop Safety Facility experiment centerline fuel thermocouple performance

    International Nuclear Information System (INIS)

    Meyers, S.C.; Henderson, J.M.

    1980-05-01

    The W-1 Sodium Loop Safety Facility (SLSF) experiment is the fifth in a series of experiments sponsored by the Department of Energy (DOE) as part of the National Fast Breeder Reactor (FBR) Safety Assurance Program. The experiments are being conducted under the direction of Argonne National Laboratory (ANL) and Hanford Engineering Development Laboratory (HEDL). The irradiation phase of the W-1 SLSF experiment was conducted between May 27 and July 20, 1979, and terminated with incipient fuel pin cladding failure during the final boiling transient. Experimental hardware and facility performed as designed, allowing completion of all planned tests and test objectives. This paper focuses on high temperature in-fuel thermocouples and discusses their development, fabrication, and performance in the W-1 experiment

  12. Thermocouple psychrometer measurements of in situ water potential changes in heated welded tuff

    International Nuclear Information System (INIS)

    Mao, Nai-hsien; Wang, H.F.

    1991-05-01

    Ten thermocouple psychrometers (TCPs) to measure water potential (WP) were installed in three holes in G-Tunnel at the Nevada Test Site as part of the Prototype Engineered Barrier System Field Tests. These integrated tests measured several parameters as a function of location and time within a few meters of a heater emplaced in welded tuff. The primary goal of the TCP experiment was to find out whether the combination of laboratory calibration and field use of the TCP can provide useful data for determining the change of moisture condition in the field. We calibrated the TCPs in NaCl solutions up to 80 degree C(176 degree F) in the laboratory. In two holes, we used rubber sleeves and packers to house TCPs, and in the third hole, we used foam. All three holes were grouted behind the TCP assemblages. Field results of the heater test showed that small temperature gradients were present for all measurements. Nevertheless, the WP calibration made the necessary correction for the nonisothermal condition. A drying and re-wetting cycle peaked at about day 140 with a WP of -65 bar in borehole P3, located below the heater. A similar cycle but reduced in scale was found at about day 175 with a WP of -45 bar in borehole P2, above the heater. This difference in drying behavior above and below the heater was also observed from neutron data and was explained as a gravity effect. As temperatures increased, the evaporation rate of pore water increased, In unfractured rock, the gas-phase flow was primarily outward. Water condensed above the heater would drain back to keep the boiling region wet, but water condensed below the heater would drain away from the boiling region. This conceptual model explained both the time and magnitude differences for data from holes above and below the heater. 7 refs., 14 figs., 2 tabs

  13. Colon and rectal cancer survival by tumor location and microsatellite instability: the Colon Cancer Family Registry.

    Science.gov (United States)

    Phipps, Amanda I; Lindor, Noralane M; Jenkins, Mark A; Baron, John A; Win, Aung Ko; Gallinger, Steven; Gryfe, Robert; Newcomb, Polly A

    2013-08-01

    Cancers in the proximal colon, distal colon, and rectum are frequently studied together; however, there are biological differences in cancers across these sites, particularly in the prevalence of microsatellite instability. We assessed the differences in survival by colon or rectal cancer site, considering the contribution of microsatellite instability to such differences. This is a population-based prospective cohort study for cancer survival. This study was conducted within the Colon Cancer Family Registry, an international consortium. Participants were identified from population-based cancer registries in the United States, Canada, and Australia. Information on tumor site, microsatellite instability, and survival after diagnosis was available for 3284 men and women diagnosed with incident invasive colon or rectal cancer between 1997 and 2002, with ages at diagnosis ranging from 18 to 74. Cox regression was used to calculate hazard ratios for the association between all-cause mortality and tumor location, overall and by microsatellite instability status. Distal colon (HR, 0.59; 95% CI, 0.49-0.71) and rectal cancers (HR, 0.68; 95% CI, 0.57-0.81) were associated with lower mortality than proximal colon cancer overall. Compared specifically with patients with proximal colon cancer exhibiting no/low microsatellite instability, patients with distal colon and rectal cancers experienced lower mortality, regardless of microsatellite instability status; patients with proximal colon cancer exhibiting high microsatellite instability had the lowest mortality. Study limitations include the absence of stage at diagnosis and cause-of-death information for all but a subset of study participants. Some patient groups defined jointly by tumor site and microsatellite instability status are subject to small numbers. Proximal colon cancer survival differs from survival for distal colon and rectal cancer in a manner apparently dependent on microsatellite instability status. These

  14. Co-C and Pd-C Eutectic Fixed Points for Radiation Thermometry and Thermocouple Thermometry

    Science.gov (United States)

    Wang, L.

    2017-12-01

    Two Co-C and Pd-C eutectic fixed point cells for both radiation thermometry and thermocouple thermometry were constructed at NMC. This paper describes details of the cell design, materials used, and fabrication of the cells. The melting curves of the Co-C and Pd-C cells were measured with a reference radiation thermometer realized in both a single-zone furnace and a three-zone furnace in order to investigate furnace effect. The transition temperatures in terms of ITS-90 were determined to be 1324.18 {°}C and 1491.61 {°}C with the corresponding combined standard uncertainty of 0.44 {°}C and 0.31 {°}C for Co-C and Pd-C, respectively, taking into account of the differences of two different types of furnaces used. The determined ITS-90 temperatures are also compared with that of INRIM cells obtained using the same reference radiation thermometer and the same furnaces with the same settings during a previous bilateral comparison exercise (Battuello et al. in Int J Thermophys 35:535-546, 2014). The agreements are within k=1 uncertainty for Co-C cell and k = 2 uncertainty for Pd-C cell. Shapes of the plateaus of NMC cells and INRIM cells are compared too and furnace effects are analyzed as well. The melting curves of the Co-C and Pd-C cells realized in the single-zone furnace are also measured by a Pt/Pd thermocouple, and the preliminary results are presented as well.

  15. Central nervous system tumors

    International Nuclear Information System (INIS)

    Curran, W.J. Jr.

    1991-01-01

    Intrinsic tumors of the central nervous system (CNS) pose a particularly challenging problem to practicing oncologists. These tumors rarely metastasize outside the CNS, yet even histologically benign tumors can be life-threatening due to their local invasiveness and strategic location. The surrounding normal tissues of the nervous system is often incapable of full functional regeneration, therefore prohibiting aggressive attempts to use either complete surgical resection or high doses of irradiation. Despite these limitations, notable achievements have recently been recorded in the management of these tumors

  16. Discordance between location of positive cores in biopsy and location of positive surgical margin following radical prostatectomy.

    Science.gov (United States)

    Kim, Ji Won; Park, Hyoung Keun; Kim, Hyeong Gon; Ham, Dong Yeub; Paick, Sung Hyun; Lho, Yong Soo; Choi, Woo Suk

    2015-10-01

    We compared location of positive cores in biopsy and location of positive surgical margin (PSM) following radical prostatectomy. This retrospective analysis included patients who were diagnosed as prostate cancer by standard 12-core transrectal ultrasonography guided prostate biopsy, and who have PSM after radical prostatectomy. After exclusion of number of biopsy cores location data, 46 patients with PSM were identified. Locations of PSM in pathologic specimen were reported as 6 difference sites (apex, base and lateral in both sides). Discordance of biopsy result and PSM was defined when no positive cores in biopsy was identified at the location of PSM. Most common location of PSM were right apex (n=21) and left apex (n=15). Multiple PSM was reported in 21 specimens (45.7%). In 32 specimens (69.6%) with PSM, one or more concordant positive biopsy cores were identified, but 14 specimens (28%) had no concordant biopsy cores at PSM location. When discordant rate was separated by locations of PSM, right apex PSM had highest rate of discordant (38%). The discordant group had significantly lower prostate volume and lower number of positive cores in biopsy than concordant group. This study showed that one fourth of PSM occurred at location where tumor was not detected at biopsy and that apex PSM had highest rate of discordant. Careful dissection to avoid PSM should be performed in every location, including where tumor was not identified in biopsy.

  17. Location of Primary Tumor and Benefit From Anti-Epidermal Growth Factor Receptor Monoclonal Antibodies in Patients With RAS and BRAF Wild-Type Metastatic Colorectal Cancer

    Science.gov (United States)

    Moretto, Roberto; Cremolini, Chiara; Rossini, Daniele; Pietrantonio, Filippo; Battaglin, Francesca; Mennitto, Alessia; Bergamo, Francesca; Loupakis, Fotios; Marmorino, Federica; Berenato, Rosa; Marsico, Valentina Angela; Caporale, Marta; Antoniotti, Carlotta; Masi, Gianluca; Salvatore, Lisa; Borelli, Beatrice; Fontanini, Gabriella; Lonardi, Sara; De Braud, Filippo

    2016-01-01

    Introduction. Right- and left-sided colorectal cancers (CRCs) differ in clinical and molecular characteristics. Some retrospective analyses suggested that patients with right-sided tumors derive less benefit from anti-epidermal growth factor receptor (EGFR) antibodies; however, molecular selection in those studies was not extensive. Patients and Methods. Patients with RAS and BRAF wild-type metastatic CRC (mCRC) who were treated with single-agent anti-EGFRs or with cetuximab-irinotecan (if refractory to previous irinotecan) were included in the study. Differences in outcome between patients with right- and left-sided tumors were investigated. Results. Of 75 patients, 14 and 61 had right- and left-sided tumors, respectively. None of the right-sided tumors responded according to RECIST, compared with 24 left-sided tumors (overall response rate: 0% vs. 41%; p = .0032), and only 2 patients with right-sided tumors (15%) versus 47 patients with left-sided tumors (80%) achieved disease control (p < .0001). The median duration of progression-free survival was 2.3 and 6.6 months in patients with right-sided and left-sided tumors, respectively (hazard ratio: 3.97; 95% confidence interval: 2.09–7.53; p < .0001). Conclusion. Patients with right-sided RAS and BRAF wild-type mCRC seemed to derive no benefit from single-agent anti-EGFRs. Implications for Practice: Right- and left-sided colorectal tumors have peculiar epidemiological and clinicopathological characteristics, distinct gene expression profiles and genetic alterations, and different prognoses. This study assessed the potential predictive impact of primary tumor site with regard to anti-epidermal growth factor receptor (EGFR) monoclonal antibody treatment in patients with RAS and BRAF wild-type metastatic colorectal cancer. The results demonstrated the lack of activity of anti-EGFRs in RAS and BRAF wild-type, right-sided tumors, thus suggesting a potential role for primary tumor location in driving treatment choices

  18. Prognostic Role of Primary Tumor Location in Non-Metastatic Gastric Cancer: A Systematic Review and Meta-Analysis of 50 Studies.

    Science.gov (United States)

    Petrelli, Fausto; Ghidini, Michele; Barni, Sandro; Steccanella, Francesca; Sgroi, Giovanni; Passalacqua, Rodolfo; Tomasello, Gianluca

    2017-09-01

    The incidence of gastric cancer (GC) arising in the upper third of the stomach, including the cardia or gastroesophageal junction (GEJ), has increased in the last decades due to established etiological risk factors such as diet, obesity, and gastroesophageal reflux. We conducted a systematic review and meta-analysis to determine the prognostic role of site of origin in patients with proximal versus distal GC. We conducted a search of the PubMed, Cochrane Library, SCOPUS, Web of Science, EMBASE, Google Scholar, LILACS, and CINAHL databases from inception to September 2016. Studies reporting data on the independent prognostic effect of site in GC and comparing overall survival (OS) in proximal versus distal tumors were eligible. Data were pooled using OS hazard ratios (HRs) of proximal versus distal GC according to fixed- or random-effect model. Overall, 50 studies including 128,268 patients were identified. Cancers located in the upper third of the stomach were associated with a significantly increased risk of all-cause mortality (HR 1.31, 95% confidence interval [CI] 1.17-1.46, p < 0.001, I 2  = 91%). After exclusion of GEJ tumors, prognosis was worse for pure cardia location (HR 1.39, 95% CI 1.22-1.58, p < 0.001, I 2  = 61%) compared with proximal or upper-third GCs without a specific subsite definition (HR 1.18, 95% CI 1.01-1.37, p = 0.04, I 2  = 91%). Location of the primary GC in the upper third of the stomach, particularly at the GEJ/cardia, should be acknowledged as an important prognostic factor. Based on these results, more effective treatment strategies for proximal GCs are needed.

  19. Cross sectional imaging of cardiac tumors

    International Nuclear Information System (INIS)

    Maksimovic, R.

    2012-01-01

    Full text: Primary cardiac tumors are a rare entity whose incidence, according to surgery and autopsy reports, is 0.3% to 0.7% of all cardiac tumors. Metastasis to the heart from other primary cancers is 30 times more common. Only 25% of primary cardiac tumors are malignant, and, of these, 75% are sarcomas. Malignant primary cardiac sarcomas are usually located in the right atrium and are most commonly angiosarcoma. In the left atrium, the most common malignant tumors are pleomorphic sarcoma and leiomyosarcoma. Symptom presentation for cardiac tumors is quite varied, but it is dependent upon tumor location and size, rather than upon histologic characteristics. Presentation includes congestive heart failure from intracardiac obstruction, systemic embolization, constitutional symptoms, and arrhythmias. Left atrial sarcomas tend to be more solid and less infiltrative than right-sided sarcomas; consequently, they tend to metastasize later. They usually present with symptoms of blood-flow obstruction and substantial, life-threatening congestive heart failure. Right-sided cardiac tumors are usually malignant and appear as bulky, infiltrative masses that grow in an outward pattern. These are usually fast-growing tumors that metastasize early and do not present with congestive heart failure until late in the disease. The diagnosis of cardiac tumors relies heavily on the use of multiple imaging techniques, including cardiac computed tomography (CT), cardiovascular magnetic resonance (CMR), and echocardiography. Important imaging data to collect include information on the size of the intracardiac mass, the mobility of the mass (an important predictor of prognosis and embolic potential), myocardial invasion, and cardiac chamber location. These factors will provide the means to diagnosis and prognosis. Other important data to collect include the mechanism of tumor implantation, the relationship of the tumor with adjacent structures, the surgeon route of access to the heart

  20. Gastroenteropancreatic neuroendocrine tumors (GEP-NETS)

    International Nuclear Information System (INIS)

    Vargas Martinez, Cristian Camilo; Castano Llano, Rodrigo

    2010-01-01

    Gastroenteropancreatic neuroendocrine tumors (GEP-NETS) are rare neoplasms which can occur anywhere in the gastrointestinal tract. Their particular characteristics include uptake of silver salts, neuroendocrine cell marker expression and hormonal secretory granules. Depending on their size, anatomical location and upon whether or not metastasis has occurred, these tumors can show different clinical patterns and have different prognoses. Early diagnosis is essential for treating these lesions and improving the patients' prognoses, but it requires a high degree of suspicion and confirmation by special testing. Surgical treatment is the first choice, but other medical therapy can be helpful for patients who have unresectable disease. This review presents the most relevant aspects of classification, morphology, methods of locating tumors, diagnosis and treatment of GEP-NETS. It presents only the Colombian experience in the epidemiology and management of these tumors.

  1. AP-PA field orientation followed by IMRT reduces lung exposure in comparison to conventional 3D conformal and sole IMRT in centrally located lung tumors

    Directory of Open Access Journals (Sweden)

    Soyfer Viacheslav

    2012-02-01

    Full Text Available Abstract Little attention has been paid to the fact that intensity modulated radiation therapy (IMRT techniques do not easily enable treatment with opposed beams. Three treatment plans (3 D conformal, IMRT, and combined (anterior-posterior-posterio-anterior (AP-PA + IMRT of 7 patients with centrally-located lung cancer were compared for exposure of lung, spinal cord and esophagus. Combined IMRT and AP-PA techniques offer better lung tissue sparing compared to plans predicated solely on IMRT for centrally-located lung tumors.

  2. Relation between the location of elements in the periodic table and tumor-uptake rate

    Energy Technology Data Exchange (ETDEWEB)

    Ando, A; Ando, I; Hiraki, T; Hisada, K

    1985-01-01

    The bipositive ions and anions, with few exceptions, indicated a low tumor uptake rate. On the other hand, compounds of Hg, Au and Bi, which have a strong binding power to protein, showed a high tumor uptake rate. As Hg/sup 2 +/, Au/sup +/ and Bi/sup 3 +/ are soft acids according to the classification of Lewis acids, it was thought that these ions would bind strongly to soft bases (R-SH, R-S-) present in tumor tissue. For many hard acids such as /sup 85/Sr/sup 2 +/, /sup 67/Ga/sup 3 +/, /sup 181/Hf/sup 4 +/, and /sup 95/Nb/sup 5 +/, tumor uptake rates are shown as a function of ionic potentials of the metal ions. Considering the present data and previously reported results, it was presumed that hard acids of trivalence, quadrivalence and pentavalence would replace calcium in the calcium salts of hard bases. Ionic potentials of alkaline metals and Tl were small, but the tumor-uptake rate of these elements indicated various values. As Ge and Sb are bound by covalent bonds to chloride, GeCl/sub 4/ and SbCl/sub 3/ behaved differently from many metallic compounds in tumor tissue.

  3. Relation between the location of elements in the periodic table and tumor-uptake rate.

    Science.gov (United States)

    Ando, A; Ando, I; Hiraki, T; Hisada, K

    1985-01-01

    The bipositive ions and anions, with few exceptions, indicated a low tumor uptake rate. On the other hand, compounds of Hg, Au and Bi, which have a strong binding power to protein, showed a high tumor uptake rate. As Hg2+, Au+ and Bi3+ are soft acids according to the classification of Lewis acids, it was thought that these ions would bind strongly to soft bases (R-SH, R-S-) present in tumor tissue. For many hard acids such as 85Sr2+, 67Ga3+, 181Hf4+, and 95Nb5+, tumor uptake rates are shown as a function of ionic potentials (valency/ionic radii) of the metal ions. Considering the present data and previously reported results, it was presumed that hard acids of trivalence, quadrivalence and pentavalence would replace calcium in the calcium salts of hard bases (calcium salts of acid mucopolysaccharides, etc.). Ionic potentials of alkaline metals and Tl were small, but the tumor-uptake rate of these elements indicated various values. As Ge and Sb are bound by covalent bonds to chloride, GeCl4 and SbCl3 behaved differently from many metallic compounds in tumor tissue.

  4. Advanced 3D image processing techniques for liver and hepatic tumor location and volumetry

    Science.gov (United States)

    Chemouny, Stephane; Joyeux, Henri; Masson, Bruno; Borne, Frederic; Jaeger, Marc; Monga, Olivier

    1999-05-01

    To assist radiologists and physicians in diagnosing, and in treatment planning and evaluating in liver oncology, we have developed a fast and accurate segmentation of the liver and its lesions within CT-scan exams. The first step of our method is to reduce spatial resolution of CT images. This will have two effects: obtain near isotropic 3D data space and drastically decrease computational time for further processing. On a second step a 3D non-linear `edge- preserving' smoothing filtering is performed throughout the entire exam. On a third step the 3D regions coming out from the second step are homogeneous enough to allow a quite simple segmentation process, based on morphological operations, under supervisor control, ending up with accurate 3D regions of interest (ROI) of the liver and all the hepatic tumors. On a fourth step the ROIs are eventually set back into the original images, features like volume and location are immediately computed and displayed. The segmentation we get is as precise as a manual one but is much faster.

  5. Echocardiographic and non-gated computed tomographic findings of intrapericardial tumor and mediastinal tumor adjacent to the heart

    International Nuclear Information System (INIS)

    Ueda, Minoru; Yamada, Nobuyuki; Saito, Daiji; Haraoka, Shoichi; Tanetani, Setsuro.

    1981-01-01

    Echocardiographic and computed tomographic findings of a case of intrapericardial tumor are reported, and two other cases of mediastinal tumor are presented in a discussion of the differential diagnosis of intrapericardial from mediastinal tumors. Case report: A 7-year-old male complained of cough and dyspnea. Cardiomegaly had been pointed out at a mass X-ray examination about a month prior to the admission. Two-dimensional echocardiography revealed a massive anterior pericardial effusion and a fist-sized tumor with cystic structure. The tumor pushed the heart backward at the level of the aortic root. Non-gated computed tomography of the chest disclosed the size and location of the tumor, but failed to clarify the internal structure. The patient underwent successful removal of a tumor, 12 x 10 x 8 cm in size and 350 g in weight, originating from the left atrial wall. Histologically, the tumor was a fibrosarcomatous mesothelioma. Usually, an intrapericardial tumor is easily suspected by echocardiography by the presence of pericardial effusion, although there have been a few reports of intrapericardial tumors without pericardial effusion. Echocardiographic diagnosis of the intrapericardial tumor is difficult in such cases. Identification of the pericardium is necessary to diagnose whether a tumor is intra- or extrapericardial. This identification, however, is not always easy by echocardiography when the ultrasonic beams become tangent to the pericardium. The pericardium between the tumor and the heart could not be identified by echocardiography in our two cases of mediastinal tumor. Computed tomography is helpful in diagnosing the size and location of a mediastinal tumor. (author)

  6. Experimental measurement of the interfacial heat transfer coefficients of subcooled flow boiling using micro-thermocouple and double directional images

    International Nuclear Information System (INIS)

    Seong-Jin Kim; Goon-Cherl Park

    2005-01-01

    Full text of publication follows: Models or correlations for phase interface are needed to analyze the multi-phase flow. Interfacial heat transfer coefficients are important to constitute energy equation of multi-phase flow, specially. In subcooled boiling flow, bubble condensation at the bubble-liquid interface is a major mechanism of heat transfer within bulk subcooled liquid. Bubble collapse rates and temperatures of each phase are needed to determine the interfacial heat transfer coefficient for bubble condensation. Bubble collapse rates were calculated through image processing in single direction, generally. And in case of liquid bulk temperature, which has been obtained by general temperature sensor such as thermocouple, was used. However, multi-directional images are needed to analyze images due to limitations of single directional image processing. Also, temperature sensor, which has a fast response time, must be used to obtain more accurate interfacial heat transfer coefficient. Low pressure subcooled water flow experiments using micro-thermocouple and double directional image processing with mirrors were conducted to investigate bubble condensation phenomena and to modify interfacial heat transfer correlation. Experiments were performed in a vertical subcooled boiling flow of a rectangular channel. Bubble condensing traces with respect to time were recorded by high speed camera in double direction and bubble collapse rates were calculated by processing recorded digital images. Temperatures were measured by micro-thermocouple, which is a K-type with a 12.7 μm diameter. The liquid temperature was estimated by the developed algorithm to discriminate phases and find each phase temperature in the measured temperature including both liquid and bubble temperature. The interfacial heat transfer coefficient for bubble condensation was calculated from the bubble collapse rates and the estimated liquid temperature, and its correlation was modified. The modified

  7. Solid renal tumor severity in von Hippel Lindau disease is related to germline deletion length and location.

    Science.gov (United States)

    Maranchie, Jodi K; Afonso, Anoushka; Albert, Paul S; Kalyandrug, Sivaram; Phillips, John L; Zhou, Shubo; Peterson, James; Ghadimi, Bijan M; Hurley, Katheen; Riss, Joseph; Vasselli, James R; Ried, Thomas; Zbar, Berton; Choyke, Peter; Walther, McClellan M; Klausner, Richard D; Linehan, W Marston

    2004-01-01

    von Hippel Lindau disease (VHL) is an autosomal dominant familial cancer syndrome linked to alteration of the VHL tumor suppressor gene. Affected patients are predisposed to develop pheochromocytomas and cystic and solid tumors of the kidney, CNS, pancreas, retina, and epididymis. However, organ involvement varies considerably among families and has been shown to correlate with the underlying germline alteration. Clinically, we observed a paradoxically lower prevalence of renal cell carcinoma (RCC) in patients with complete germline deletion of VHL. To determine if a relationship existed between the type of VHL deletion and disease, we retrospectively evaluated 123 patients from 55 families with large germline VHL deletions, including 42 intragenic partial deletions and 13 complete VHL deletions, by history and radiographic imaging. Each individual and family was scored for cystic or solid involvement of CNS, pancreas, and kidney, and for pheochromocytoma. Germline deletions were mapped using a combination of fluorescent in situ hybridization (FISH) and quantitative Southern and Southern blot analysis. An age-adjusted comparison demonstrated a higher prevalence of RCC in patients with partial germline VHL deletions relative to complete deletions (48.9 vs. 22.6%, p=0.007). This striking phenotypic dichotomy was not seen for cystic renal lesions or for CNS (p=0.22), pancreas (p=0.72), or pheochromocytoma (p=0.34). Deletion mapping revealed that development of RCC had an even greater correlation with retention of HSPC300 (C3orf10), located within the 30-kb region of chromosome 3p, immediately telomeric to VHL (52.3 vs. 18.9%, p <0.001), suggesting the presence of a neighboring gene or genes critical to the development and maintenance of RCC. Careful correlation of genotypic data with objective phenotypic measures will provide further insight into the mechanisms of tumor formation. Copyright 2003 Wiley-Liss, Inc.

  8. Laparoscopic liver resection for hepatocellular carcinoma in cirrhotic patients. Feasibility of nonanatomic resection in difficult tumor locations

    Directory of Open Access Journals (Sweden)

    Marco Casaccia

    2011-01-01

    Full Text Available Background: Surgical resection for hepatocellular carcinoma (HCC in cirrhotic patients remains controversial because of high morbidity and recurrence rates. Laparoscopic resection of liver tumors has recently been developed and could reduce morbidity. The aim of this study was to evaluate retrospectively our results for laparoscopic liver resection (LLR for HCC including lesions in the posterosuperior segments of the liver in terms of feasibility, outcome, recurrence and survival. Materials and Methods: Between June 2005 and February 2009, we performed 20 LLR for HCC. Median age of the patients was 66 years. The underlying cirrhosis was staged as Child A in 17 cases and Child B in 3. Results: LLR included anatomic resection in six cases and nonanatomic resection in 14. Eleven procedures were associated in nine (45% patients. Median tumor size and surgical margins were 3.1 cm and 15 mm, respectively. A conversion to laparotomy occurred in one (5% patient for hemorrhage. Mortality and morbidity rates were 0% and 15% (3/20. Median hospital stay was 8 days (range: 5-16 days. Over a mean follow-up period of 26 months (range: 19-62 months, 10 (50% patients presented recurrence, mainly at distance from the surgical site. Treatment of recurrence was possible in all the patients, including orthotopic liver transplantation in three cases. Conclusions: LLR for HCC in selected patients is a safe procedure with good short-term results. It can also be proposed in tumor locations with a difficult surgical access maintaining a low morbidity rate and good oncological adequacy. This approach could have an impact on the therapeutic strategy of HCC complicating cirrhosis as a treatment with curative intent or as a bridge to liver transplantation.

  9. Nuclear location of tumor suppressor protein maspin inhibits proliferation of breast cancer cells without affecting proliferation of normal epithelial cells

    International Nuclear Information System (INIS)

    Machowska, Magdalena; Wachowicz, Katarzyna; Sopel, Mirosław; Rzepecki, Ryszard

    2014-01-01

    Maspin, which is classified as a tumor suppressor protein, is downregulated in many types of cancer. Several studies have suggested potential anti-proliferative activity of maspin as well as sensitizing activity of maspin for therapeutic cytotoxic agents in breast cancer tissue culture and animal models. All of the experimental data gathered so far have been based on studies with maspin localized cytoplasmically, while maspin in breast cancer tumor cells may be located in the cytoplasm, nucleus or both. In this study, the effect of maspin cytoplasmic and nuclear location and expression level on breast cancer proliferation and patient survival was studied. Tissue sections from 166 patients with invasive ductal breast cancer were stained by immunohistochemistry for maspin and Ki-67 protein. The localization and expression level of maspin were correlated with estimated patient overall survival and percent of Ki-67-positive cells. In further studies, we created constructs for transient transfection of maspin into breast cancer cells with targeted cytoplasmic and nuclear location. We analyzed the effect of maspin location in normal epithelial cell line MCF10A and three breast cancer cell lines - MCF-7, MDA-MB-231 and SKBR-3 - by immunofluorescence and proliferation assay. We observed a strong positive correlation between moderate and high nuclear maspin level and survival of patients. Moreover, a statistically significant negative relationship was observed between nuclear maspin and Ki-67 expression in patients with invasive ductal breast cancer. Spearman’s correlation analysis showed a negative correlation between level of maspin localized in nucleus and percentage of Ki-67 positive cells. No such differences were observed in cells with cytoplasmic maspin. We found a strong correlation between nuclear maspin and loss of Ki-67 protein in breast cancer cell lines, while there was no effect in normal epithelial cells from breast. The anti-proliferative effect of nuclear

  10. Nuclear location of tumor suppressor protein maspin inhibits proliferation of breast cancer cells without affecting proliferation of normal epithelial cells

    Science.gov (United States)

    2014-01-01

    Background Maspin, which is classified as a tumor suppressor protein, is downregulated in many types of cancer. Several studies have suggested potential anti-proliferative activity of maspin as well as sensitizing activity of maspin for therapeutic cytotoxic agents in breast cancer tissue culture and animal models. All of the experimental data gathered so far have been based on studies with maspin localized cytoplasmically, while maspin in breast cancer tumor cells may be located in the cytoplasm, nucleus or both. In this study, the effect of maspin cytoplasmic and nuclear location and expression level on breast cancer proliferation and patient survival was studied. Methods Tissue sections from 166 patients with invasive ductal breast cancer were stained by immunohistochemistry for maspin and Ki-67 protein. The localization and expression level of maspin were correlated with estimated patient overall survival and percent of Ki-67-positive cells. In further studies, we created constructs for transient transfection of maspin into breast cancer cells with targeted cytoplasmic and nuclear location. We analyzed the effect of maspin location in normal epithelial cell line MCF10A and three breast cancer cell lines - MCF-7, MDA-MB-231 and SKBR-3 - by immunofluorescence and proliferation assay. Results We observed a strong positive correlation between moderate and high nuclear maspin level and survival of patients. Moreover, a statistically significant negative relationship was observed between nuclear maspin and Ki-67 expression in patients with invasive ductal breast cancer. Spearman’s correlation analysis showed a negative correlation between level of maspin localized in nucleus and percentage of Ki-67 positive cells. No such differences were observed in cells with cytoplasmic maspin. We found a strong correlation between nuclear maspin and loss of Ki-67 protein in breast cancer cell lines, while there was no effect in normal epithelial cells from breast. The anti

  11. Investigation of pool boiling dynamics on a rectangular heater using nano-thermocouples: is it chaotic or stochastic?

    Energy Technology Data Exchange (ETDEWEB)

    Sathyamurthi, Vijaykumar; Banerjee, Debjyoti [Texas A and M University, College Station, TX (United States). Dept. of Mechanical Engineering], e-mail: dbanerjee@tamu.edu

    2009-07-01

    The non-linear dynamical model of pool boiling on a horizontal rectangular heater is assessed from experimental results in this study. Pool boiling experiments are conducted over a horizontal rectangular silicon substrate measuring 63 mm x 35 mm with PF-5060 as the test fluid. Novel nano-thermocouples, micro-machined in-situ on the silicon substrate are used to measure the surface temperature fluctuations for steady state pool boiling. The acquisition frequency for temperature data from the nano-thermocouples is 1 k Hz. The surface temperature fluctuations are analyzed using the TISEAN{sup c} package. A time-delay embedding is employed to generate higher dimensional phase-space vectors from the temperature time series record. The optimal delay is determined from the first minimum of the mutual information function. Techniques such as recurrence plots, and false nearest neighbors tests are employed to assess the presence of deterministic chaotic dynamics. Chaos quantifiers such as correlation dimensions are found for various pool boiling regimes using the raw data as well as noise-reduced data. Additionally, pseudo-phase spaces are used to reconstruct the 'attractors'. The results after non-linear noise reduction shows definitive presence of low-dimensional (d {<=} 7) chaos in fully developed nucleate boiling, at critical heat flux and in film boiling. (author)

  12. Investigation of pool boiling dynamics on a rectangular heater using nano-thermocouples: is it chaotic or stochastic?

    International Nuclear Information System (INIS)

    Sathyamurthi, Vijaykumar; Banerjee, Debjyoti

    2009-01-01

    The non-linear dynamical model of pool boiling on a horizontal rectangular heater is assessed from experimental results in this study. Pool boiling experiments are conducted over a horizontal rectangular silicon substrate measuring 63 mm x 35 mm with PF-5060 as the test fluid. Novel nano-thermocouples, micro-machined in-situ on the silicon substrate are used to measure the surface temperature fluctuations for steady state pool boiling. The acquisition frequency for temperature data from the nano-thermocouples is 1 k Hz. The surface temperature fluctuations are analyzed using the TISEAN c package. A time-delay embedding is employed to generate higher dimensional phase-space vectors from the temperature time series record. The optimal delay is determined from the first minimum of the mutual information function. Techniques such as recurrence plots, and false nearest neighbors tests are employed to assess the presence of deterministic chaotic dynamics. Chaos quantifiers such as correlation dimensions are found for various pool boiling regimes using the raw data as well as noise-reduced data. Additionally, pseudo-phase spaces are used to reconstruct the 'attractors'. The results after non-linear noise reduction shows definitive presence of low-dimensional (d ≤ 7) chaos in fully developed nucleate boiling, at critical heat flux and in film boiling. (author)

  13. MRI of cystic pituitary tumors

    Energy Technology Data Exchange (ETDEWEB)

    Tokunaga, Hitoshi; Hoshi, Seiichiro; Sunada, Souichi; Sunami, Kenro [Kawatetsu Chiba Hospital (Japan); Saeki, Naokatsu; Yamaura, Akira

    1998-11-01

    We retrospectively reviewed MRI findings of 17 patients with 3 histologically proven cystic pituitary tumors. They consisted of 10 cystic pituitary adenomas, 4 craniopharyngiomas and 3 Rathke`s cleft cysts. We analyzed the following MRI parameters such as cyst wall appearance, enhancement pattern of cyst wall, location of residual pituitary gland and location of tumor. They were clinically significant parameters for histological differentiation. Even though combinations of such MRI parameters helped for more accurate preoperative diagnosis, the differentiation between craniopharyngioma and Rathke`s cleft cyst was difficult in some cases. (author)

  14. MRI of cystic pituitary tumors

    International Nuclear Information System (INIS)

    Tokunaga, Hitoshi; Hoshi, Seiichiro; Sunada, Souichi; Sunami, Kenro; Saeki, Naokatsu; Yamaura, Akira

    1998-01-01

    We retrospectively reviewed MRI findings of 17 patients with 3 histologically proven cystic pituitary tumors. They consisted of 10 cystic pituitary adenomas, 4 craniopharyngiomas and 3 Rathke's cleft cysts. We analyzed the following MRI parameters such as cyst wall appearance, enhancement pattern of cyst wall, location of residual pituitary gland and location of tumor. They were clinically significant parameters for histological differentiation. Even though combinations of such MRI parameters helped for more accurate preoperative diagnosis, the differentiation between craniopharyngioma and Rathke's cleft cyst was difficult in some cases. (author)

  15. Anatomical location differences between mutated and wild-type isocitrate dehydrogenase 1 in low-grade gliomas.

    Science.gov (United States)

    Yu, Jinhua; Shi, Zhifeng; Ji, Chunhong; Lian, Yuxi; Wang, Yuanyuan; Chen, Liang; Mao, Ying

    2017-10-01

    Anatomical location of gliomas has been considered as a factor implicating the contributions of a specific precursor cells during the tumor growth. Isocitrate dehydrogenase 1 (IDH1) is a pathognomonic biomarker with a significant impact on the development of gliomas and remarkable prognostic effect. The correlation between anatomical location of tumor and IDH1 states for low-grade gliomas was analyzed quantitatively in this study. Ninety-two patients diagnosed of low-grade glioma pathologically were recruited in this study, including 65 patients with IDH1-mutated glioma and 27 patients with wide-type IDH1. A convolutional neural network was designed to segment the tumor from three-dimensional magnetic resonance imaging images. Voxel-based lesion symptom mapping was then employed to study the tumor location distribution differences between gliomas with mutated and wild-type IDH1. In order to characterize the location differences quantitatively, the Automated Anatomical Labeling Atlas was used to partition the standard brain atlas into 116 anatomical volumes of interests (AVOIs). The percentages of tumors with different IDH1 states in 116 AVOIs were calculated and compared. Support vector machine and AdaBoost algorithms were used to estimate the IDH1 status based on the 116 location features of each patient. Experimental results proved that the quantitative tumor location measurement could be a very important group of imaging features in biomarker estimation based on radiomics analysis of glioma.

  16. Successful Endovascular Control of Renal Artery in a Transplant Kidney During Nephron Sparing Surgery (NSS) for Large Centrally Located Tumor.

    Science.gov (United States)

    Shprits, Sagi; Moskovits, Boaz; Sachner, Robert; Nativ, Ofer

    2016-05-01

    Renal cell carcinoma in a transplant kidney is a rare condition. Nephron Sparing Surgery (NSS) is the treatment of choice. One of the main technical challenges is obtaining adequate vascular control. We present a rare case of large centrally located hillar tumor in a kidney 18 years after transplantation treated with NSS. Vascular control was achieved by using a novel approach. Post-operative course was uneventful with minimal decrease in renal function. We believe that this unique choice of treatment can be used in cases of NSS where the access to the renal pedicle is limited.

  17. Extragastrointestinal Stromal Tumor: A Differential Diagnosis of Compressive Upper Abdominal Tumor

    Directory of Open Access Journals (Sweden)

    Clara Kimie Miyahira

    2018-01-01

    Full Text Available Introduction. Extragastrointestinal stromal tumors (EGIST are rare mesenchymal tumor lesions located outside the gastrointestinal tract. A rare compressing tumor with difficult diagnosis is reported. Presentation of the Case. A male patient, 63 years old, was admitted in the emergency room complaining of stretching and continuous abdominal pain for one day. He took Hyoscine, with partial improvement of symptoms, but got worse due to hyporexia, and the abdominal pain persisted. The patient also reported early satiety and ten-pound weight loss over the last month. Discussion. EGIST could be assessed by CT-guided biopsy, leading to diagnosis and proper treatment with surgical resection or Imatinib. Conclusion. This case report highlights the importance of considering EGIST an important differential diagnosis of compressing upper abdominal tumors.

  18. Unusually Located Stroke After Chemotherapy in Testicular Germ Cell Tumors

    Directory of Open Access Journals (Sweden)

    Braulio Alexander Martinez MD

    2015-06-01

    Full Text Available Testicular cancer is a type of malignancy that affects young adults and has high rates of cure; however, as any malignancy, it is associated with an increased risk of ischemic or hemorrhagic cerebrovascular disease, given the systemic tumor effects or side effects of chemotherapy, which in turn increases morbidity, functional impairment, and additional risk of early death.

  19. Boiling detection using signals of self-powered neutron detectors and thermocouples

    International Nuclear Information System (INIS)

    Kozma, R.

    1989-01-01

    A specially-equipped simulated fuel assembly has been placed into the core of the 2 MW research reactor of the IRI, Delft. In this paper the recent results concerning the detection of coolant boiling in the simulated fuel assembly are introduced. Applying the theory of boiling temperature noise, different stages of boiling, i.e. one-phase flow, subcooled boiling, volume boiling, were identified in the measurements using the low-frequency noise components of the thermocouple signals. It has been ascertained that neutron noise spectra remained unchanged when subcooled boiling appeared, and that they changed reasonably only when developed volume boiling took place in the channels. At certain neutron detector positions neutron spectra did not vary at all, although developed volume boiling occurred at a distance of 3-4 cm from these neutron detectors. This phenomenon was applied in studying the field-of-view of neutron detectors

  20. [Tumor and tumor-like benign mesenchymal lesions of the breast].

    Science.gov (United States)

    Bisceglia, M; Nirchio, V; Carosi, I; Cappucci, U; Decata, A; Paragone, T; Di Mattia, A L

    1995-02-01

    All the spectrum is encompassed of those miscellaneous pathologic entities occurring in the mammary stroma which are on record up to date other than "mixed fibroepithelial" tumors (fibroadenomas and phyllodes tumors) and tumors both "pure" and "mixed" originating from myoepithelium (adenomyoepitheliomas and pleomorphic adenomas). Also they were excluded those dysreactive-autoimmune diseases (sarcoidosis, sclerosing lymphocytic lobulitis, lobular granulomatous mastitis) and those inflammatory-infectious conditions (tuberculosis, actinomycosis, foreign body reactions, Mondor's disease) which can mimick breast tumors clinically or on image analysis, but on the contrary not evoking the idea of a tumor on histology. Specifically, inflammatory pseudotumor, myofibroblastoma, leiomyoma, neurinoma/neurofibroma, benign fibrous histiocytoma, hemangiopericytoma, fibromatosis, nodular fascitis, variants of lipoma, mesenchymoma, amartoma and its variants, hemangiomas, pseudoangiomatous hyperplasia of stroma, amyloid tumor, granular cell tumor, are consecutively described and discussed, with a large list of references enclosed to each rubric. Most of the pictures are taken from personally observed lesions of the breast. Only few pictures referred to are from their analogue lesions which occurred in soft parts of other locations, with specific mention of that when it was the case. Of note after reviewing the literature the fact that no glomus tumor, nor Kaposi's sarcoma either sporadic or in the context of any immunodeficiency, nor myelolipoma has been recorded yet.

  1. Cone-Beam Computed Tomography (CBCT) Hepatic Arteriography in Chemoembolization for Hepatocellular Carcinoma: Performance Depicting Tumors and Tumor Feeders

    Energy Technology Data Exchange (ETDEWEB)

    Lee, In Joon [National Cancer Center, Department of Radiology (Korea, Republic of); Chung, Jin Wook, E-mail: chungjw@snu.ac.kr; Yin, Yong Hu; Kim, Hyo-Cheol; Kim, Young Il; Jae, Hwan Jun; Park, Jae Hyung [Seoul National University College of Medicine, Seoul National University Hospital, Department of Radiology (Korea, Republic of)

    2015-10-15

    PurposeThis study was designed to analyze retrospectively the performance of cone-beam computed tomography (CBCT) hepatic arteriography in depicting tumors and their feeders and to investigate the related determining factors in chemoembolization for hepatocellular carcinoma (HCC).MethodsEighty-six patients with 142 tumors satisfying the imaging diagnosis criteria of HCC were included in this study. The performance of CBCT hepatic arteriography for chemoembolization per tumor and per patient was evaluated using maximum intensity projection images alone (MIP analysis) or MIP combined with multiplanar reformation images (MIP + MPR analysis) regarding the following three aspects: tumor depiction, confidence of tumor feeder detection, and trackability of tumor feeders. Tumor size, tumor enhancement, tumor location, number of feeders, diaphragmatic motion, portal vein enhancement, and hepatic artery to parenchyma enhancement ratio were regarded as potential determining factors.ResultsTumors were depicted in 125 (88.0 %) and 142 tumors (100 %) on MIP and MIP + MPR analysis, respectively. Imaging performances on MIP and MIP + MPR analysis were good enough to perform subsegmental chemoembolization without additional angiographic investigation in 88 (62.0 %) and 128 tumors (90.1 %) on per-tumor basis and in 43 (50 %) and 73 (84.9 %) on per-patient basis, respectively. Significant determining factors for performance in MIP + MPR analysis on per tumor basis were tumor size (p = 0.030), tumor enhancement (0.005), tumor location (p = 0.001), and diaphragmatic motion (p < 0.001).ConclusionsCBCT hepatic arteriography provided sufficient information for subsegmental chemoembolization by depicting tumors and their feeders in the vast majority of patients. Combined analysis of MIP and MPR images was essential to enhance the performance of CBCT hepatic arteriography.

  2. Retroperitoneal "triton" tumor. Report of a case and review of literature

    Directory of Open Access Journals (Sweden)

    Palacios Acosta José Martín

    2014-07-01

    Full Text Available The triton tumor was described in 1932 by Masson, as a peripheral nerve sheath malignancy with rabdomioblástica differentiation. The retroperitoneal location is extremely rare, only nine cases have been reported in children. The clinical picture depends on the size of the tumor and the organs involved, their retroperitoneal location is usually asymptomatic. The mainstay of treatment is the surgical excision of the tumor. We report the case of a child with retroperitoneal location of the tumor. A complete resection of it was performed. The patient had an uneventful postoperative course. He is currently under control. There is no evidence of relapse.

  3. Improving Tumor Treating Fields Treatment Efficacy in Patients With Glioblastoma Using Personalized Array Layouts

    International Nuclear Information System (INIS)

    Wenger, Cornelia; Salvador, Ricardo; Basser, Peter J.; Miranda, Pedro C.

    2016-01-01

    Purpose: To investigate tumors of different size, shape, and location and the effect of varying transducer layouts on Tumor Treating Fields (TTFields) distribution in an anisotropic model. Methods and Materials: A realistic human head model was generated from MR images of 1 healthy subject. Four different virtual tumors were placed at separate locations. The transducer arrays were modeled to mimic the TTFields-delivering commercial device. For each tumor location, varying array layouts were tested. The finite element method was used to calculate the electric field distribution, taking into account tissue heterogeneity and anisotropy. Results: In all tumors, the average electric field induced by either of the 2 perpendicular array layouts exceeded the 1-V/cm therapeutic threshold value for TTFields effectiveness. Field strength within a tumor did not correlate with its size and shape but was higher in more superficial tumors. Additionally, it always increased when the array was adapted to the tumor's location. Compared with a default layout, the largest increase in field strength was 184%, and the highest average field strength induced in a tumor was 2.21 V/cm. Conclusions: These results suggest that adapting array layouts to specific tumor locations can significantly increase field strength within the tumor. Our findings support the idea of personalized treatment planning to increase TTFields efficacy for patients with GBM.

  4. Improving Tumor Treating Fields Treatment Efficacy in Patients With Glioblastoma Using Personalized Array Layouts

    Energy Technology Data Exchange (ETDEWEB)

    Wenger, Cornelia, E-mail: cwenger@fc.ul.pt [Institute of Biophysics and Biomedical Engineering, Faculdade de Ciências, Universidade de Lisboa, Lisbon (Portugal); Salvador, Ricardo [Institute of Biophysics and Biomedical Engineering, Faculdade de Ciências, Universidade de Lisboa, Lisbon (Portugal); Basser, Peter J. [Section on Tissue Biophysics and Biomimetics, Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, Bethesda, Maryland (United States); Miranda, Pedro C. [Institute of Biophysics and Biomedical Engineering, Faculdade de Ciências, Universidade de Lisboa, Lisbon (Portugal)

    2016-04-01

    Purpose: To investigate tumors of different size, shape, and location and the effect of varying transducer layouts on Tumor Treating Fields (TTFields) distribution in an anisotropic model. Methods and Materials: A realistic human head model was generated from MR images of 1 healthy subject. Four different virtual tumors were placed at separate locations. The transducer arrays were modeled to mimic the TTFields-delivering commercial device. For each tumor location, varying array layouts were tested. The finite element method was used to calculate the electric field distribution, taking into account tissue heterogeneity and anisotropy. Results: In all tumors, the average electric field induced by either of the 2 perpendicular array layouts exceeded the 1-V/cm therapeutic threshold value for TTFields effectiveness. Field strength within a tumor did not correlate with its size and shape but was higher in more superficial tumors. Additionally, it always increased when the array was adapted to the tumor's location. Compared with a default layout, the largest increase in field strength was 184%, and the highest average field strength induced in a tumor was 2.21 V/cm. Conclusions: These results suggest that adapting array layouts to specific tumor locations can significantly increase field strength within the tumor. Our findings support the idea of personalized treatment planning to increase TTFields efficacy for patients with GBM.

  5. Parotid hybrid tumor

    International Nuclear Information System (INIS)

    Bravo C, Gustavo; Seymour M, Camila; Fernandez R, Lara; Villanueva I, Maria Elena; Scott C, Carlos; Celedon L, Carlos

    2012-01-01

    Tumors of the salivary glands represent 33%-10% of head and neck neoplasms. The most common location is the parotid gland, accounting for 50%-85% of the cases, with 20%-30% of them being malignant. The following are known to be indicative of a malignant tumor: fast growing, painless mass, associated facial paralysis and lymphadenopathy. Most parotid neoplasm derive from a single histological type but eventually the development of more than one type on the same gland can occur. This paper presents a case of a parotid neoplasm with two different histological tumors, with uncharacteristic clinical presentation. The patient presented initially with ear pain and otorrhoea, in the clinical examination highlighted an external auditory canal tumor. The complementary study revealed a parotid neoplasm and a total resection of the gland was performed. The biopsy revealed an adenoid-cystic carcinoma with differentiated basaloid areas. Adjuvant radio-chemotherapy was administered, and the imaging control with PET-CT showed no evidence of recurrence or dissemination of the tumor

  6. Tile Surface Thermocouple Measurement Challenges from the Orbiter Boundary Layer Transition Flight Experiment

    Science.gov (United States)

    Campbell, Charles H.; Berger, Karen; Anderson, Brian

    2012-01-01

    Hypersonic entry flight testing motivated by efforts seeking to characterize boundary layer transition on the Space Shuttle Orbiters have identified challenges in our ability to acquire high quality quantitative surface temperature measurements versus time. Five missions near the end of the Space Shuttle Program implemented a tile surface protuberance as a boundary layer trip together with tile surface thermocouples to capture temperature measurements during entry. Similar engineering implementations of these measurements on Discovery and Endeavor demonstrated unexpected measurement voltage response during the high heating portion of the entry trajectory. An assessment has been performed to characterize possible causes of the issues experienced during STS-119, STS-128, STS-131, STS-133 and STS-134 as well as similar issues encountered during other orbiter entries.

  7. Influence of Fractionation Scheme and Tumor Location on Toxicities After Stereotactic Body Radiation Therapy for Large (≥5 cm) Non-Small Cell Lung Cancer: A Multi-institutional Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Verma, Vivek [Department of Radiation Oncology, University of Nebraska Medical Center, Omaha, Nebraska (United States); Shostrom, Valerie K. [Department of Biostatistics, College of Public Health, University of Nebraska Medical Center, Omaha, Nebraska (United States); Zhen, Weining; Zhang, Mutian [Department of Radiation Oncology, University of Nebraska Medical Center, Omaha, Nebraska (United States); Braunstein, Steve E. [Department of Radiation Oncology, University of California, San Francisco, San Francisco, California (United States); Holland, John [Department of Radiation Medicine, Oregon Health & Science University, Portland, Oregon (United States); Hallemeier, Christopher L. [Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota (United States); Harkenrider, Matthew M. [Department of Radiation Oncology, Loyola University Stritch School of Medicine, Maywood, Illinois (United States); Iskhanian, Adrian [Department of Radiation Oncology, University of Miami Sylvester Comprehensive Cancer Center, Miami, Florida (United States); Jabbour, Salma K. [Department of Radiation Oncology, Rutgers Cancer Institute of New Jersey, Rutgers University, New Brunswick, New Jersey (United States); Attia, Albert [Department of Radiation Oncology, Vanderbilt University School of Medicine, Nashville, Tennessee (United States); Lee, Percy [Department of Radiation Oncology, David Geffen School of Medicine at UCLA, Los Angeles, California (United States); Wang, Kyle [Department of Radiation Oncology, University of North Carolina School of Medicine, Chapel Hill, North Carolina (United States); Decker, Roy H. [Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut (United States); McGarry, Ronald C. [Department of Radiation Oncology, University of Kentucky, Lexington, Kentucky (United States); Simone, Charles B., E-mail: charlessimone@umm.edu [Department of Radiation Oncology, University of Maryland Medical Center, Baltimore, Maryland (United States)

    2017-03-15

    Purpose: To describe the impact of fractionation scheme and tumor location on toxicities in stereotactic body radiation therapy (SBRT) for ≥5-cm non-small cell lung cancer (NSCLC), as part of a multi-institutional analysis. Methods: Patients with primary ≥5-cm N0 M0 NSCLC who underwent ≤5-fraction SBRT were examined across multiple high-volume SBRT centers. Collected data included clinical/treatment parameters; toxicities were prospectively assessed at each institution according to the Common Terminology Criteria for Adverse Events. Patients treated daily were compared with those treated every other day (QOD)/other nondaily regimens. Stratification between central and peripheral tumors was also performed. Results: Ninety-two patients from 12 institutions were evaluated (2004-2016), with median follow-up of 12 months. In total there were 23 (25%) and 6 (7%) grade ≥2 and grade ≥3 toxicities, respectively. Grades 2 and 3 pulmonary toxicities occurred in 9% and 4%, respectively; 1 patient treated daily experienced grade 5 radiation pneumonitis. Of the entire cohort, 46 patients underwent daily SBRT, and 46 received QOD (n=40)/other nondaily (n=6) regimens. Clinical/treatment parameters were similar between groups; the QOD/other group was more likely to receive 3-/4-fraction schemas. Patients treated QOD/other experienced significantly fewer grade ≥2 toxicities as compared with daily treatment (7% vs 43%, P<.001). Patients treated daily also had higher rates of grade ≥2 pulmonary toxicities (P=.014). Patients with peripheral tumors (n=66) were more likely to receive 3-/4-fraction regimens than those with central tumors (n=26). No significant differences in grade ≥2 toxicities were identified according to tumor location (P>.05). Conclusions: From this multi-institutional study, toxicity of SBRT for ≥5-cm lesions is acceptable, and daily treatment was associated with a higher rate of toxicities.

  8. [Relation between location of elements in periodic table and affinity for the malignant tumor (author's transl)].

    Science.gov (United States)

    Ando, A; Hisada, K; Ando, I

    1977-10-01

    Affinity of many inorganic compounds for the malignant tumor was examined, using the rats which were subcutaneously transplanted with Yoshida sarcoma. And the relations between the uptake rate into the malignant tumor and in vitro binding power to the protein were investigated in these compounds. In these experiments, the bipositive ions and anions had not affinity for the tumor tissue with a few exceptions. On the other hand, Hg, Au and Bi, which have strong binding power to the protein, showed high uptake rate into the malignant tumor. As Hg++, Au+ and Bi+++ are soft acids according to classification of Lewis acids, it was thought that these elements would bind strongly to soft base (R-SH, R-S-) present in the tumor tissue. In many hard acids (according to classification of Lewis acids), the uptake rate into the tumor was shown as a function of ionic potentials (valency/ionic radii) of the metal ions. It is presumed that the chemical bond of these hard acids in the tumor tissue is ionic bond to hard base (R-COO-, R-PO3(2-), R-SO3-, R-NH2).

  9. A preliminary study of oxidation-resistant coatings on refractory-metal thermocouple sheaths

    International Nuclear Information System (INIS)

    Wilkins, S.C.

    1985-01-01

    The need to make reliable temperature measurements up to 2200 0 C or higher in steam environments during in-pile nuclear fuel damage tests led to a search for oxidation-resistant coatings for the refractory-metal sheaths used to enclose and protect thermocouples used for such measurements. Iridium, thoria, and thoria-over-iridium coatings were separately sputter-deposited on molybdenum-rhenium alloy protection tubes for evaluation. The coated samples were individually heated in flowing steam in an induction furnace. An extension tube welded to each sample was connected to a vacuum pump and gauge; failure of the sample was detected by noting the degradation of the vacuum maintained in the sample. Relatively heavy coatings of iridium provided a modest degree of oxidation protection at the temperatures of interest. Thoria coatings provided no significant protection at those temperatures, compared to uncoated control samples

  10. Radiofrequency ablation of pulmonary tumors near the diaphragm.

    Science.gov (United States)

    Iguchi, T; Hiraki, T; Gobara, H; Fujiwara, H; Sakurai, J; Matsui, Y; Mitsuhashi, T; Toyooka, S; Kanazawa, S

    To retrospectively evaluate the feasibility, safety, and efficacy of radiofrequency ablation (RFA) of lung tumors located near the diaphragm. A total of 26 patients (15 men, 11 women; mean age, 61.5 years±13.0 [SD]) with a total of 29 lung tumors near the diaphragm (i.e., distance<10mm) were included. Mean tumor diameter was 11.0mm±5.3 (SD) (range, 2-23mm). Efficacy of RFA, number of adverse events and number of adverse events with a grade≥3, based on the National Cancer Institute Common Terminology Criteria for Adverse Events, version 4.0, were compared between patients with lung tumors near the diaphragm and a control group of patients with more distally located lung tumors (i.e., distance≥10mm). RFA was technically feasible for all tumors near the diaphragm. Four grade 3 adverse events (1 pneumothorax requiring pleurodesis and 3 phrenic nerve injuries) were observed. No grade≥4 adverse events were reported. The median follow-up period for tumors near the diaphragm was 18.3 months. Local progression was observed 3.3 months after RFA in 1 tumor. The technique efficacy rates were 96.2% at 1 year and 96.2% at 2 years and were not different, from those observed in control subjects (186 tumors; P=0.839). Shoulder pain (P<0.001) and grade 1 pleural effusion (P<0.001) were more frequently observed in patients with lung tumor near the diaphragm. The rates of grade≥3 adverse events did not significantly differ between tumors near the diaphragm (4/26 sessions) and the controls (7/133 sessions) (P=0.083). RFA is a feasible and effective therapeutic option for lung tumors located near the diaphragm. However, it conveys a higher rate of shoulder pain and asymptomatic pleural effusion by comparison with more distant lung tumors. Copyright © 2017 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  11. Malignant gastroduodenal stromal tumor imaging diagnosis

    International Nuclear Information System (INIS)

    Guo Qiang; Wen Feng; Zhao Zhenguo

    2010-01-01

    Objective: To assess the imaging features of malignant gastroduodenal stromal tumor (mGDST)as an aid to its diagnosis. Methods: The unenhanced and multi-phasic contrast-enhanced CT scans of 24 patients with pathologically proven mGDST and air-contrast upper gastrointestinal studies(15 patients) were reviewed by two radiologists. The tumor location, size, contour, margin, growth type, contrast enhancement pattern and presence of ulcer were recorded. Results: The mGDST was located in the gastric fundus (15), gastric body(3), pylorus(2) and duodenum(4). The pathological types were submucosal(9), intramuscular(9) and subserosal(6). CT findings of mGDST included lobular shape(17), tumor size>5cm(14), central necrosis(15), large and deep ulcer(6), heterogeneous contrast enhancement(1), metastasis(1). The diagnostic accuracy of air-contrast upper gastrointestinal studies and CT for location of mGDST was 93.3% and 100% respectively, for malignant features was both 75.0%. Conclusion: Most mGDST have some characteristic appearances including large tumor size greater than 5 cm, lobular shape, central necrosis, large and deep ulcer, heterogeneous contrast enhancement and metastasis. Lymph node enlargement was uncommon. The diagnostic accuracy can be improved by CT scan combined with upper gastrointestinal barium examination. (authors)

  12. Congenital tumors of the central nervous system

    International Nuclear Information System (INIS)

    Severino, Mariasavina; Schwartz, Erin S.; Thurnher, Majda M.; Rydland, Jana; Nikas, Ioannis; Rossi, Andrea

    2010-01-01

    Congenital tumors of the central nervous system (CNS) are often arbitrarily divided into ''definitely congenital'' (present or producing symptoms at birth), ''probably congenital'' (present or producing symptoms within the first week of life), and ''possibly congenital'' (present or producing symptoms within the first 6 months of life). They represent less than 2% of all childhood brain tumors. The clinical features of newborns include an enlarged head circumference, associated hydrocephalus, and asymmetric skull growth. At birth, a large head or a tense fontanel is the presenting sign in up to 85% of patients. Neurological symptoms as initial symptoms are comparatively rare. The prenatal diagnosis of congenital CNS tumors, while based on ultrasonography, has significantly benefited from the introduction of prenatal magnetic resonance imaging studies. Teratomas constitute about one third to one half of these tumors and are the most common neonatal brain tumor. They are often immature because of primitive neural elements and, rarely, a component of mixed malignant germ cell tumors. Other tumors include astrocytomas, choroid plexus papilloma, primitive neuroectodermal tumors, atypical teratoid/rhabdoid tumors, and medulloblastomas. Less common histologies include craniopharyngiomas and ependymomas. There is a strong predilection for supratentorial locations, different from tumors of infants and children. Differential diagnoses include spontaneous intracranial hemorrhage that can occur in the presence of coagulation factor deficiency or underlying vascular malformations, and congenital brain malformations, especially giant heterotopia. The prognosis for patients with congenital tumors is generally poor, usually because of the massive size of the tumor. However, tumors can be resected successfully if they are small and favorably located. The most favorable outcomes are achieved with choroid plexus tumors, where aggressive surgical treatment leads to disease

  13. Tumor location and patient characteristics of colon and rectal adenocarcinomas in relation to survival and TNM classes

    International Nuclear Information System (INIS)

    Hemminki, Kari; Santi, Irene; Weires, Marianne; Thomsen, Hauke; Sundquist, Jan; Bermejo, Justo Lorenzo

    2010-01-01

    Old age at diagnosis is associated with poor survival in colorectal cancer (CRC) for unknown reasons. Recent data show that colonoscopy is efficient in preventing left-sided cancers only. We examine the association of Tumor Node Metastasis (TNM) classes with diagnostic age and patient characteristics. The Swedish Family-Cancer Database has data on TNM classes on 6,105 CRC adenocarcinoma patients. Ordinal logistic regression analysis was performed to model tumor characteristics according to age at diagnosis, tumor localization, gender, socioeconomic status, medical region and family history. The results were compared to results from survival analysis. The only parameters systematically associated with TNM classes were age and tumor localization. Young age at diagnosis was a risk factor for aggressive CRC, according to stage, N and M with odds ratios (ORs) ranging from 1.80 to 1.93 for diagnosis before age 50 years compared to diagnosis at 80+ years. All tumor characteristics, particularly T, were worse for colon compared to rectal tumors. Right-sided tumors showed worse characteristics for all classifiers but M. The survival analysis on patients diagnosed since 2000 showed a hazard ratio of 0.55 for diagnosis before age 50 years compared to diagnosis at over 80 years and a modestly better prognosis for left-sided compared to right-sided tumors. The results showed systematically more aggressive tumors in young compared to old patients. The poorer survival of old patients in colon cancer was not related to the available tumor characteristics. However, these partially agreed with the limited colonoscopic success with right-sided tumors

  14. Frequency of Odontogenic Tumors in Zahedan-Iran from 2000 to 2010

    Directory of Open Access Journals (Sweden)

    Hamideh Kadeh

    2012-01-01

    Full Text Available Introduction: Odontogenic tumors constitute an important aspect of oral and maxillofacial pathology. Frequency of odontogenic tumors varies in different societies but no study has been done in Zahedan so far. The purpose of this study was to achieve the sex, location and age distribution of odontogenic tumors and frequency of each one in a period of ten years.Materials & Methods: In this study, documents in archive of maxillofacial pathology department of Zahedan dental school, Khatamolanbia, Tamin ejtemaei Hospital and private laboratories were reviewed from 2000 to 2010. Data about age, sex, location of tumors and relation with impacted tooth were extracted and were submitted in the forms.Results: In this study, among the 1125 cases of the oromaxillofacial lesions, 50 cases of odontogenic tumors were found. Among the different tumors, keratocyst odontogenic tumor (KOT was the most common odontogenic tumor (48%, followed by ameloblastoma and odontoma with frequency of 24% and 12%, respectively. There were no cases of malignancy. The incidence of these lesions was 52% in women and 48% in men. The most common location of tumors was posterior of mandible and tumors were more frequent in the third decade of life. In 12 cases, the lesions were accompanied by impacted teeth.Conclusion: In this study the most frequent tumors were KOT, Ameloblastoma and odontoma respectively.

  15. Description of an identification method of thermocouple time constant based on application of recursive numerical filtering to temperature fluctuation

    International Nuclear Information System (INIS)

    Bernardin, B.; Le Guillou, G.; Parcy, JP.

    1981-04-01

    Usual spectral methods, based on temperature fluctuation analysis, aiming at thermocouple time constant identification are using an equipment too much sophisticated for on-line application. It is shown that numerical filtering is optimal for this application, the equipment is simpler than for spectral methods and less samples of signals are needed for the same accuracy. The method is described and a parametric study was performed using a temperature noise simulator [fr

  16. Imaging Tumor Necrosis with Ferumoxytol.

    Directory of Open Access Journals (Sweden)

    Maryam Aghighi

    Full Text Available Ultra-small superparamagnetic iron oxide nanoparticles (USPIO are promising contrast agents for magnetic resonance imaging (MRI. USPIO mediated proton relaxation rate enhancement is strongly dependent on compartmentalization of the agent and can vary depending on their intracellular or extracellular location in the tumor microenvironment. We compared the T1- and T2-enhancement pattern of intracellular and extracellular USPIO in mouse models of cancer and pilot data from patients. A better understanding of these MR signal effects will enable non-invasive characterizations of the composition of the tumor microenvironment.Six 4T1 and six MMTV-PyMT mammary tumors were grown in mice and imaged with ferumoxytol-enhanced MRI. R1 relaxation rates were calculated for different tumor types and different tumor areas and compared with histology. The transendothelial leakage rate of ferumoxytol was obtained by our measured relaxivity of ferumoxytol and compared between different tumor types, using a t-test. Additionally, 3 patients with malignant sarcomas were imaged with ferumoxytol-enhanced MRI. T1- and T2-enhancement patterns were compared with histopathology in a descriptive manner as a proof of concept for clinical translation of our observations.4T1 tumors showed central areas of high signal on T1 and low signal on T2 weighted MR images, which corresponded to extracellular nanoparticles in a necrotic core on histopathology. MMTV-PyMT tumors showed little change on T1 but decreased signal on T2 weighted images, which correlated to compartmentalized nanoparticles in tumor associated macrophages. Only 4T1 tumors demonstrated significantly increased R1 relaxation rates of the tumor core compared to the tumor periphery (p<0.001. Transendothelial USPIO leakage was significantly higher for 4T1 tumors (3.4±0.9x10-3 mL/min/100cm3 compared to MMTV-PyMT tumors (1.0±0.9x10-3 mL/min/100 cm3. Likewise, ferumoxytol imaging in patients showed similar findings with

  17. Brain tumors in children; Hirntumoren beim Kind

    Energy Technology Data Exchange (ETDEWEB)

    Harting, I.; Seitz, A. [Universitaetsklinikum Heidelberg (Germany). Abt. Neuroradiologie

    2009-06-15

    Brain tumors are common in children; in Germany approximately 400 children are diagnosed every year. In the posterior fossa, cerebellar neoplasms outnumber brainstem gliomas. In contrast to their rarity in adults, brainstem gliomas are not uncommon in children. Supratentorial tumors can be subdivided by location into neoplasms of the cerebral hemispheres, suprasellar and pineal tumors. Astrocytoma is the most common pediatric brain tumor followed by medulloblastoma, ependymoma and craniopharyngeoma. The combination of imaging morphology, tumor localisation and patient age at manifestation form the basis of the neuroradiological differential diagnosis. (orig.)

  18. Operating Temperatures of a Sodium-Cooled Exhaust Valve as Measured by a Thermocouple

    Science.gov (United States)

    Sanders, J. C.; Wilsted, H. D.; Mulcahy, B. A.

    1943-01-01

    A thermocouple was installed in the crown of a sodium-cooled exhaust valve. The valve was then tested in an air-cooled engine cylinder and valve temperatures under various engine operating conditions were determined. A temperature of 1337 F was observed at a fuel-air ratio of 0.064, a brake mean effective pressure of 179 pounds per square inch, and an engine speed of 2000 rpm. Fuel-air ratio was found to have a large influence on valve temperature, but cooling-air pressure and variation in spark advance had little effect. An increase in engine power by change of speed or mean effective pressure increased the valve temperature. It was found that the temperature of the rear spark-plug bushing was not a satisfactory indication of the temperature of the exhaust valve.

  19. Tumor location and detectability in mammographic screening

    International Nuclear Information System (INIS)

    Schmitt, E.L.; Threatt, B.

    1982-01-01

    The adequacy of a film mammogram that does not visualize the retromammary space or ribs has concerned radiologists. The 79 prevalent cancers detected in the 10,000 self-referred woman at the University of Michigan Breast Cancer Detection Demonstration Project were analyzed for number of films required to detect the cancer, relationship of the cancer to the posterior edge of the film, number of occult lesions, tumor size, histologic type, sensitivity of detection method, and number of interval carcinomas. The mammograms were obtained using a dedicated mammographic machine and the upright position, with visualization of the anterior axillary fold on the mediolateral view. The ribs were not imaged. Of the 79 cancers, 76 were detectable on the mammogram. All were visualized on the mediolateral view, while three were not imaged on the craniocaudal view. Twelve percent of the cancers were within 1 cm of the posterior edge of the film. Only six ''interval'' carcinomas were found in the 10,000 patients within the year of the initial examinations; these women had dense P2 or DY mammographic parenchymal patterns. The detected cancers were smaller and had a significantly higher percentage of noninvasive cancers than in a symptomatic clinical population. Thus, properly exposed film mammograms using vigorous breast compression examine the breast adequately without visualizing the ribs

  20. Congenital tumors of the central nervous system

    Energy Technology Data Exchange (ETDEWEB)

    Severino, Mariasavina [G. Gaslini Children' s Hospital, Department of Neuroradiology, Genoa (Italy); Schwartz, Erin S. [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Thurnher, Majda M. [Medical University of Vienna, Department of Radiology, Vienna (Austria); Rydland, Jana [MR Center, St. Olav' s Hospital HF, Trondheim (Norway); Nikas, Ioannis [Agia Sophia Children' s Hospital, Imaging Department, Athens (Greece); Rossi, Andrea [G. Gaslini Children' s Hospital, Department of Neuroradiology, Genoa (Italy); G. Gaslini Children' s Hospital, Department of Pediatric Neuroradiology, Genoa (Italy)

    2010-06-15

    Congenital tumors of the central nervous system (CNS) are often arbitrarily divided into ''definitely congenital'' (present or producing symptoms at birth), ''probably congenital'' (present or producing symptoms within the first week of life), and ''possibly congenital'' (present or producing symptoms within the first 6 months of life). They represent less than 2% of all childhood brain tumors. The clinical features of newborns include an enlarged head circumference, associated hydrocephalus, and asymmetric skull growth. At birth, a large head or a tense fontanel is the presenting sign in up to 85% of patients. Neurological symptoms as initial symptoms are comparatively rare. The prenatal diagnosis of congenital CNS tumors, while based on ultrasonography, has significantly benefited from the introduction of prenatal magnetic resonance imaging studies. Teratomas constitute about one third to one half of these tumors and are the most common neonatal brain tumor. They are often immature because of primitive neural elements and, rarely, a component of mixed malignant germ cell tumors. Other tumors include astrocytomas, choroid plexus papilloma, primitive neuroectodermal tumors, atypical teratoid/rhabdoid tumors, and medulloblastomas. Less common histologies include craniopharyngiomas and ependymomas. There is a strong predilection for supratentorial locations, different from tumors of infants and children. Differential diagnoses include spontaneous intracranial hemorrhage that can occur in the presence of coagulation factor deficiency or underlying vascular malformations, and congenital brain malformations, especially giant heterotopia. The prognosis for patients with congenital tumors is generally poor, usually because of the massive size of the tumor. However, tumors can be resected successfully if they are small and favorably located. The most favorable outcomes are achieved with choroid plexus tumors

  1. Peripheral tumor and tumor-like neurogenic lesions

    Energy Technology Data Exchange (ETDEWEB)

    Abreu, Evandro [Service de Radiologie et Imagerie Musculosquelettique, Centre de Consultation et Imagerie de l’Appareil Locomoteur, CHRU de Lille, 59037 Lille (France); Aubert, Sébastien, E-mail: sebastien.aubert@chru-lille.fr [Institut de Pathologie, Centre de Biologie-Pathologie, CHRU de Lille, 59037 Lille (France); Wavreille, Guillaume, E-mail: guillaume.wavreille@chru-lille.fr [Service d’Orthopédie B, Hôpital R Salengro, CHRU de Lille, 59037 Lille (France); Gheno, Ramon; Canella, Clarissa [Service de Radiologie et Imagerie Musculosquelettique, Centre de Consultation et Imagerie de l’Appareil Locomoteur, CHRU de Lille, 59037 Lille (France); Cotten, Anne, E-mail: anne.cotten@chru-lille.fr [Service de Radiologie et Imagerie Musculosquelettique, Centre de Consultation et Imagerie de l’Appareil Locomoteur, CHRU de Lille, 59037 Lille (France)

    2013-01-15

    Neoplasms of neurogenic origin account for about 12% of all benign and 8% of all malignant soft tissue neoplasms. Traumatic neuroma, Morton neuroma, lipomatosis of a nerve, nerve sheath ganglion, perineurioma, benign and malignant peripheral nerve sheath tumors (PNST) are included in this group of pathologies. Clinical and radiologic evaluation of patients with neurogenic tumors and pseudotumors often reveals distinctive features. In this context, advanced imaging techniques, especially ultrasound (US) and magnetic resonance (MR) play an important role in the characterization of these lesions. Imaging findings such as location of a soft tissue mass in the region of a major nerve, nerve entering or exiting the mass, fusiform shape, abnormalities of the muscle supplied by the nerve, split-fat sign, target sign and fascicular appearance should always evoke a peripheric nerve sheath neoplasm. Although no single imaging finding or combination of findings allows definitive differentiation between benign from malign peripheric neurogenic tumors, both US and MR imaging may show useful features that can lead us to a correct diagnosis and improve patient treatment. Traumatic neuromas and Morton neuromas are commonly associated to an amputation stump or are located in the intermetatarsal space. Lipomatosis of a nerve usually appears as a nerve enlargement, with thickened nerve fascicles, embedded in evenly distributed fat. Nerve sheath ganglion has a cystic appearance and commonly occurs at the level of the knee. Intraneural perineuroma usually affects young people and manifests as a focal and fusiform nerve enlargement. In this article, we review clinical characteristics and radiologic appearances of these neurogenic lesions, observing pathologic correlation, when possible.

  2. Investigation of the Relationship Between Gross Tumor Volume Location and Pneumonitis Rates Using a Large Clinical Database of Non-Small-Cell Lung Cancer Patients

    International Nuclear Information System (INIS)

    Vinogradskiy, Yevgeniy; Tucker, Susan L.; Liao Zhongxing; Martel, Mary K.

    2012-01-01

    Purpose: Studies have suggested that function may vary throughout the lung, and that patients who have tumors located in the base of the lung are more susceptible to radiation pneumonitis. The purpose of our study was to investigate the relationship between gross tumor volume (GTV) location and pneumonitis rates using a large clinical database of 547 patients with non–small-cell lung cancer. Methods and Materials: The GTV centroids of all patients were mapped onto one common coordinate system, in which the boundaries of the coordinate system were defined by the extreme points of each individual patient lung. The data were qualitatively analyzed by graphing all centroids and displaying the data according to the presence of severe pneumonitis, tumor stage, and smoking status. The centroids were grouped according to superior–inferior segments, and the pneumonitis rates were analyzed. In addition, we incorporated the GTV centroid information into a Lyman–Kutcher–Burman normal tissue complication probability model and tested whether adding spatial information significantly improved the fit of the model. Results: Of the 547 patients analyzed, 111 (20.3%) experienced severe radiation pneumonitis. The pneumonitis incidence rates were 16%, 23%, and 21% for the superior, middle, and inferior thirds of the lung, respectively. Qualitatively, the GTV centroids of nonsmokers were notably absent from the superior portion of the lung. In addition, the GTV centroids of patients who had Stage III and IV clinical staging were concentrated toward the medial edge of the lung. The comparison between the GTV centroid model and the conventional dose–volume model did not yield a statistically significant difference in model fit. Conclusions: Lower pneumonitis rates were noted for the superior portion of the lung; however the differences were not statistically significant. For our patient cohort, incorporating GTV centroid information did not lead to a statistically significant

  3. Investigation of the relationship between gross tumor volume location and pneumonitis rates using a large clinical database of non-small-cell lung cancer patients.

    Science.gov (United States)

    Vinogradskiy, Yevgeniy; Tucker, Susan L; Liao, Zhongxing; Martel, Mary K

    2012-04-01

    Studies have suggested that function may vary throughout the lung, and that patients who have tumors located in the base of the lung are more susceptible to radiation pneumonitis. The purpose of our study was to investigate the relationship between gross tumor volume (GTV) location and pneumonitis rates using a large clinical database of 547 patients with non-small-cell lung cancer. The GTV centroids of all patients were mapped onto one common coordinate system, in which the boundaries of the coordinate system were defined by the extreme points of each individual patient lung. The data were qualitatively analyzed by graphing all centroids and displaying the data according to the presence of severe pneumonitis, tumor stage, and smoking status. The centroids were grouped according to superior-inferior segments, and the pneumonitis rates were analyzed. In addition, we incorporated the GTV centroid information into a Lyman-Kutcher-Burman normal tissue complication probability model and tested whether adding spatial information significantly improved the fit of the model. Of the 547 patients analyzed, 111 (20.3%) experienced severe radiation pneumonitis. The pneumonitis incidence rates were 16%, 23%, and 21% for the superior, middle, and inferior thirds of the lung, respectively. Qualitatively, the GTV centroids of nonsmokers were notably absent from the superior portion of the lung. In addition, the GTV centroids of patients who had Stage III and IV clinical staging were concentrated toward the medial edge of the lung. The comparison between the GTV centroid model and the conventional dose-volume model did not yield a statistically significant difference in model fit. Lower pneumonitis rates were noted for the superior portion of the lung; however the differences were not statistically significant. For our patient cohort, incorporating GTV centroid information did not lead to a statistically significant improvement in the fit of the pneumonitis model. Copyright

  4. Brain tumors and CT scans in infants and children, (3)

    International Nuclear Information System (INIS)

    Oi, Shizuo

    1983-01-01

    In clinical pictures of brain tumors in infants and children, many features are not identical to those in adults, including characteristics of the tumors in age population, the locations of the tumors, the clinical symptoms and signs, and various factors affecting prognosis. We have, therefore, clinically and extensively analyzed brain tumors in infants and children. This study was also performed in order to analyze the characteristic CT findings of astrocytoma, the tumor most frequently occurring among infants and children. The subjects were 24 cases of astrocytoma and 2 cases of glioblastoma in infants and children under 16 years. The locations and characteristics of the tumors were as follows. Most of the tumors occurred in the 4th ventricle, had a characteristic low density, and could almost entirely be clearly distinguished from medulloblastomas, but not from ependymomas, on CT. The features of the supratentorial tumors were similar to those of the astrocytomas and glioblastomas mostly appearing in adults, as previously reported, in the relatively close correlation with the location and malignancy of the tumor. There was also a case of diffuse astrocytoma, a ''non-enhanced low-density solid tumor,'' which raised clinical problems. Among low-grade astrocytomas in infants and children, only a few show a high density on plain CT, many have, at least macroscopically, a strong contrast enhancement, and peritumoral edema is not observed on CT or, if observed, is observed only slightly. As individual features, homogenous enhancement pattern, a mixed density, a central low density, and a rare absence of enhancement are listed. (author)

  5. Tumoral calcinosis-like lesion of the proximal linea aspera

    International Nuclear Information System (INIS)

    Seeger, L.L.; Butler, D.L.; Eckardt, J.J.; Layfield, L.; Adams, J.S.

    1990-01-01

    Tumoral calcinosis is presently a poorly defined disease. In its classic form, it consists of multiple large foci of benign mineralization in the soft tissue adjacent to bone near large joints. Patients are generally of African descent and are adolescents or young adults at presentation. Both metabolic and traumatic etiologies have been proposed. We report six adult Caucasian patients with lesions that pathologically resembled tumoral calcinosis. All lesions were small (less than 3x3 cm) and were located along the proximal linea aspera lof the femur. All patients presented with pain. Because of the atypical patient population and the unusual size and location of the lesions, we refer to this process as a 'tumoral calcinosis-like lesion'. A typical radiographic appearance and location, together with appropriate clinical history, can strongly suggest this diagnosis. (orig.)

  6. Robot-assisted partial nephrectomy for hilar tumors: perioperative outcomes.

    Science.gov (United States)

    Eyraud, Rémi; Long, Jean-Alexandre; Snow-Lisy, Devon; Autorino, Riccardo; Hillyer, Shahab; Klink, Joseph; Rizkala, Emad; Stein, Robert J; Kaouk, Jihad H; Haber, Georges-Pascal

    2013-06-01

    To compare perioperative outcomes of robot-assisted partial nephrectomy (RAPN) for hilar vs nonhilar tumors. The study retrospectively reviewed 364 patients with available computed tomography scans undergoing RAPN. Demographic data and perioperative outcomes results were compared between the hilar (group 1, n = 70) and nonhilar tumors (group 2, n = 294). Multivariate analysis was used to identify predictors of warm ischemia time (WIT), estimated blood loss (EBL), major perioperative complications, and postoperative renal function. There were no differences with respect to demographic variables. Hilar tumors had higher RENAL (radius, exophytic/endophytic properties of the tumor, nearness of tumor deepest portion to the collecting system or sinus, anterior/posterior descriptor and the location relative to polar lines) scores (P hilar tumors were associated with greater operative time (210 vs 180 minutes, P hilar vs nonhilar patients on postoperative day 3 (70.12 vs 74.71 mL/min/1.73 m(2), P = .31) or at last follow-up (72.62 vs 75.78 mL/min/1.73 m(2), P = .40), respectively. Multivariate analysis found hilar location was independently associated with increased WIT without significant changes in EBL, major complications, or postoperative renal function. RAPN represents a safe and effective procedure for hilar tumors. Hilar location for patients undergoing RAPN in a high-volume institution seems not be associated with an increased risk of transfusions, major complications, or decline of early postoperative renal function. Copyright © 2013 Elsevier Inc. All rights reserved.

  7. CNS tumors: postoperative evaluation

    International Nuclear Information System (INIS)

    Dayanir, Y.

    2012-01-01

    Full text: Imaging assessment of brain tumors following surgery is complex and depends upon several factors, including the location of the tumor, the surgical procedure and the disease process for which it was performed. Depending upon these factors, one or a combination of complementary imaging modalities may be required to demonstrate any clinically relevant situation, to assist the surgeon in deciding if repeat surgery is necessary. Conventional magnetic resonance imaging (MRI) can show the shape, size, signal intensity, and enhancement of a brain tumor. It has been widely used to diagnose and differentiate brain tumors and to assess the surgery outcomes. Longitudinal MRI scans have also been applied for the assessment of treatment and response to surgery. The newly developed MRI techniques, including diffusion weighted imaging (DWI), perfusion weighted imaging (PWI) and magnetic resonance spectroscopy (MRS), have the potential to provide the molecular, functional and metabolic information of preoperative and postoperative brain tumors. Postoperative diffusion and perfusion magnetic resonance imaging are especially useful in predicting early functional recovery from new deficits after brain tumor surgery.This lecture will stress the principles, applications, and pitfalls of conventional as well as newly developing functional imaging techniques following operation of brain tumors

  8. Clinical Significance of Lymph Node Metastasis in the Mesentery of the Terminal Ileum in Patients With Right-sided Colon Tumors at Different Locations.

    Science.gov (United States)

    Kang, Sung Il; Kim, Duck-Woo; Shin, Eun; Kim, Myung Jo; Son, Il Tae; Oh, Heung-Kwon; Kang, Sung-Bum

    2018-06-01

    There are limited reports on peri-ileal lymph node metastasis in patients with right-sided colon cancer, and little is known about their clinical significance. This study aimed to examine the role of tumor location in the prevalence and clinical significance of peri-ileal lymph node metastasis in patients with right-sided colon cancer. This is a retrospective study from a prospective cohort database. The study was conducted at a tertiary referral hospital. Patients with right-sided colon cancer treated with radical surgery in a hospital between May 2006 and September 2016 were included. The frequency of peri-ileal lymph node metastasis in the study cohort and the role of tumor location and the clinical characteristics of patients with peri-ileal lymph node metastasis were determined. We examined 752 cases with right-sided colon cancer including 82 cecal, 554 ascending colon, and 116 hepatic flexure cancer. Twenty patients (2.7%) had peri-ileal lymph node metastasis. The incidence of metastasis to peri-ileal lymph nodes was 7.3% (6/82) in patients with cecal cancer, 2.2% (12/554) in patients with ascending colon cancer, and 1.7% (2/116) in patients with hepatic flexure cancer. Three patients had stage III cancer and 17 had stage IV. All 3 patients with positive peri-ileal lymph nodes and stage III cancer had cecal tumors. In contrast, all patients with ascending colon or hepatic flexure cancer and positive peri-ileal lymph nodes had stage IV cancer. The results were limited by the retrospective design of the study and the small number of patients with peri-ileal lymph node metastasis. Peri-ileal lymph node metastasis was rare even in right-sided colon cancer and occurred mainly in stage IV. However, it occurred in some patients with locally advanced cecal cancer. These results suggest that optimal resection of the mesentery of the terminal ileum might have clinical benefit, especially in curative surgery for cecal cancer. See Video Abstract at http

  9. Comparison of two surface temperature measurement using thermocouples and infrared camera

    Directory of Open Access Journals (Sweden)

    Michalski Dariusz

    2017-01-01

    Full Text Available This paper compares two methods applied to measure surface temperatures at an experimental setup designed to analyse flow boiling heat transfer. The temperature measurements were performed in two parallel rectangular minichannels, both 1.7 mm deep, 16 mm wide and 180 mm long. The heating element for the fluid flowing in each minichannel was a thin foil made of Haynes-230. The two measurement methods employed to determine the surface temperature of the foil were: the contact method, which involved mounting thermocouples at several points in one minichannel, and the contactless method to study the other minichannel, where the results were provided with an infrared camera. Calculations were necessary to compare the temperature results. Two sets of measurement data obtained for different values of the heat flux were analysed using the basic statistical methods, the method error and the method accuracy. The experimental error and the method accuracy were taken into account. The comparative analysis showed that although the values and distributions of the surface temperatures obtained with the two methods were similar but both methods had certain limitations.

  10. Percutaneous Irreversible Electroporation of a Large Centrally Located Hepatocellular Adenoma in a Woman with a Pregnancy Wish

    International Nuclear Information System (INIS)

    Scheffer, Hester J.; Melenhorst, Marleen C. A. M.; Tilborg, Aukje A. J. M. van; Nielsen, Karin; Nieuwkerk, Karin M. van; Vries, Richard A. de; Tol, Petrousjka van den; Meijerink, Martijn R.

    2015-01-01

    Irreversible electroporation (IRE) is a novel image-guided ablation technique that is rapidly gaining popularity in the treatment of malignant liver tumors located near large vessels or bile ducts. We describe a 28-year-old female patient with a 5 cm large, centrally located hepatocellular adenoma who wished to get pregnant. Regarding the risk of growth and rupture of the adenoma caused by hormonal changes during pregnancy, treatment of the tumor was advised prior to pregnancy. However, due to its central location, the tumor was considered unsuitable for resection and thermal ablation. Percutaneous CT-guided IRE was performed without complications and led to rapid and impressive tumor shrinkage. Subsequent pregnancy and delivery went uncomplicated. This case report suggests that the indication for IRE may extend to the treatment of benign liver tumors that cannot be treated safely otherwise

  11. Percutaneous Irreversible Electroporation of a Large Centrally Located Hepatocellular Adenoma in a Woman with a Pregnancy Wish

    Energy Technology Data Exchange (ETDEWEB)

    Scheffer, Hester J., E-mail: hj.scheffer@vumc.nl; Melenhorst, Marleen C. A. M., E-mail: m.melenhorst@vumc.nl; Tilborg, Aukje A. J. M. van, E-mail: a.vantilborg@vumc.nl [VU University Medical Center, Department of Radiology and Nuclear Medicine (Netherlands); Nielsen, Karin, E-mail: k.nielsen@vumc.nl [Department of Surgery (Netherlands); Nieuwkerk, Karin M. van, E-mail: cmj.vannieuwkerk@vumc.nl; Vries, Richard A. de, E-mail: ra.devries@vumc.nl [VU University Medical Center, Department of Gastroenterology and Hepatology (Netherlands); Tol, Petrousjka van den [Department of Surgery (Netherlands); Meijerink, Martijn R., E-mail: mr.meijerink@vumc.nl [VU University Medical Center, Department of Radiology and Nuclear Medicine (Netherlands)

    2015-08-15

    Irreversible electroporation (IRE) is a novel image-guided ablation technique that is rapidly gaining popularity in the treatment of malignant liver tumors located near large vessels or bile ducts. We describe a 28-year-old female patient with a 5 cm large, centrally located hepatocellular adenoma who wished to get pregnant. Regarding the risk of growth and rupture of the adenoma caused by hormonal changes during pregnancy, treatment of the tumor was advised prior to pregnancy. However, due to its central location, the tumor was considered unsuitable for resection and thermal ablation. Percutaneous CT-guided IRE was performed without complications and led to rapid and impressive tumor shrinkage. Subsequent pregnancy and delivery went uncomplicated. This case report suggests that the indication for IRE may extend to the treatment of benign liver tumors that cannot be treated safely otherwise.

  12. Predicting the "usefulness" of 5-ALA-derived tumor fluorescence for fluorescence-guided resections in pediatric brain tumors

    DEFF Research Database (Denmark)

    Stummer, Walter; Rodrigues, Floriano; Schucht, Philippe

    2014-01-01

    fluorescence was "useful", i.e., leading to changes in surgical strategy or identification of residual tumor. Recursive partitioning analysis (RPA) was used for defining cohorts with high or low likelihoods for useful fluorescence. RESULTS: Data on 78 patients ..., 25 %) and pilocytic astrocytomas (two of 13; 15 %). RPA of pre-operative factors showed tumors with supratentorial location, strong contrast enhancement and first operation to have a likelihood of useful fluorescence of 64.3 %, as opposed to infratentorial tumors with first surgery (23...

  13. Malignant Glomus Tumor of the Peritoneum: Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Baleato-González, Sandra; García-Figueiras, Roberto; Trujillo-Ariza, Maria Virginia [Department of Radiology, Complexo Hospitalario Universitario de Santiago de Compostela, Choupana s/n, 15701 Santiago de Compostela (A Coruña) (Spain); Carrera-Álvarez, Juan Jose [Department of Pathology, Complexo Hospitalario Universitario de Santiago de Compostela, Choupana s/n, 15701 Santiago de Compostela (A Coruña) (Spain)

    2014-07-01

    Glomus tumors are usually benign tumors that occur in the skin and soft tissues of the extremities. Visceral locations, such as stomach, intestines or lung, are extremely rare because glomus bodies are rare or absent in these organs. This report describes our experience in a 47-year-old woman diagnosed with a peritoneal malignant glomus tumor. This finding has not been previously reported.

  14. Malignant Glomus Tumor of the Peritoneum: Case Report

    International Nuclear Information System (INIS)

    Baleato-González, Sandra; García-Figueiras, Roberto; Trujillo-Ariza, Maria Virginia; Carrera-Álvarez, Juan Jose

    2014-01-01

    Glomus tumors are usually benign tumors that occur in the skin and soft tissues of the extremities. Visceral locations, such as stomach, intestines or lung, are extremely rare because glomus bodies are rare or absent in these organs. This report describes our experience in a 47-year-old woman diagnosed with a peritoneal malignant glomus tumor. This finding has not been previously reported

  15. Energy deposition measurements in fast reactor safety experiments with fission thermocouple detectors

    International Nuclear Information System (INIS)

    Wright, S.A.; Scott, H.L.

    1979-01-01

    The investigation of phenomena occurring in in-pile fast reactor safety experiments requires an accurate measurement of the time dependent energy depositions within the fissile material. At Sandia Laboratories thin-film fission thermocouples are being developed for this purpose. These detectors have high temperature capabilities (400 to 500 0 C), are sodium compatible, and have milli-second time response. A significant advantage of these detectors for use as energy deposition monitors is that they produce an output voltage which is directly dependent on the temperature of a small chip of fissile material within the detectors. However, heat losses within the detector make it necessary to correct the response of the detector to determine the energy deposition. A method of correcting the detector response which uses an inverse convolution procedure has been developed and successfully tested with experimental data obtained in the Sandia Pulse Reactor (SPR-II) and in the Annular Core Research Reactor

  16. SMORN-1: thermoelectrically generated noise in sheathed thermocouples and in other low level instrumentation cables

    International Nuclear Information System (INIS)

    Mathieu, F.; Meier, R.; Soenen, M.; Delcon, M.; Nysten, C.

    Starting from the fact that thermoelectric emfs of thermocouples are generated in the thermal gradients and not at the hot junction, it is shown how thermoelectric heterogeneity in conjunction with natural and forced convection phenomena gives rise to unwanted noise called: ''thermoelectric noise'' in the technological sense. A distinction is made between four different types of noise--i.e. uncorrelated noise, correlated noise, spectral noise and thermoelectric noise in the physical sense--each of which has its own characteristics. The experimental results presented reveal that noise amplitudes may be quite embarrassing when dealing with problems of quantitative signal fluctuation analysis. It is however emphasized that thermoelectric noise may also convey useful information which, without noise, might be lost

  17. CT morphology of benign median nerve tumors

    International Nuclear Information System (INIS)

    Feyerabend, T.; Schmitt, R.; Lanz, U.; Warmuth-Metz, M.; Wuerzburg Univ.

    1990-01-01

    Computed tomography (CT) was performed in 3 patients with benign tumors of the median nerve, histologically confirmed as neurilemmoma, fibrolipoma and hemangioma. The neurilemmoma showed a ring-shaped contrast enhancement. The fibrolipoma presented with areas of solid soft tissue and areas of fat. The hemangioma was a solid tumor with a lacunar, vascular contrast enhancement. According to our experience and to the previous literature CT gives useful information regarding the anatomic location, size, and relationship of peripheral nerve sheath tumors to surrounding structures, and may help to differentiate between various tumor types. (orig.)

  18. Tumor motion and deformation during external radiotherapy of bladder cancer

    International Nuclear Information System (INIS)

    Lotz, Heidi T.; Pos, Floris J.; Hulshof, Maarten C.C.M.; Herk, Marcel van; Lebesque, Joos V.; Duppen, Joop C.; Remeijer, Peter

    2006-01-01

    Purpose: First, to quantify bladder-tumor motion in 3 dimensions during a 4-week to 5-week course of external radiotherapy. Second, to relate the motion to the tumor location on the bladder wall. Third, to extensively evaluate gross tumor volume (GTV) shape and volume changes during the course of the treatment. Methods and Materials: Multiple repeat computed tomography (CT) images were obtained for 21 bladder cancer patients. These scans were matched to the rigid bony anatomy. For each patient, the main direction and magnitude of the tumor movement was determined by use of principle-component analysis. To study GTV shape changes, all GTVs were registered to the GTV in the planning CT scan, and the residual shape errors were determined by measurement of edge variations perpendicular to the median surface. Results: Gross tumor volume translations were largest in cranial-caudal and anterior-posterior direction (SD, 0.1 to ∼0.9 cm). The translations were strongly correlated with the tumor location on the bladder wall. The average value of the local standard deviations of the GTV shape ranged from 0.1 to approximately 0.35 cm. Conclusions: Despite large differences in bladder filling, variations in GTV shape were small compared with variations in GTV position. Geometric uncertainties in the GTV position depended strongly on the tumor location on the bladder wall

  19. Tumor motion and deformation during external radiotherapy of bladder cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lotz, Heidi T [Department of Radiation Oncology, Netherlands Cancer Institute, Antoni van Leeuwenhoek Hospital, Amsterdam (Netherlands); Department of Radiation Oncology, Academic Medical Centre, University of Amsterdam, Amsterdam (Netherlands); Pos, Floris J [Department of Radiation Oncology, Netherlands Cancer Institute, Antoni van Leeuwenhoek Hospital, Amsterdam (Netherlands); Hulshof, Maarten C.C.M. [Department of Radiation Oncology, The Netherlands Cancer Institute, Antoni van Leeuwenhoek Hospital, Amsterdam (Netherlands); Department of Radiation Oncology, Academic Medical Centre, University of Amsterdam, Amsterdam (Netherlands); Herk, Marcel van [Department of Radiation Oncology, Netherlands Cancer Institute, Antoni van Leeuwenhoek Hospital, Amsterdam (Netherlands); Lebesque, Joos V [Department of Radiation Oncology, Netherlands Cancer Institute, Antoni van Leeuwenhoek Hospital, Amsterdam (Netherlands); Duppen, Joop C [Department of Radiation Oncology, Netherlands Cancer Institute, Antoni van Leeuwenhoek Hospital, Amsterdam (Netherlands); Remeijer, Peter [Department of Radiation Oncology, Netherlands Cancer Institute, Antoni van Leeuwenhoek Hospital, Amsterdam (Netherlands)

    2006-04-01

    Purpose: First, to quantify bladder-tumor motion in 3 dimensions during a 4-week to 5-week course of external radiotherapy. Second, to relate the motion to the tumor location on the bladder wall. Third, to extensively evaluate gross tumor volume (GTV) shape and volume changes during the course of the treatment. Methods and Materials: Multiple repeat computed tomography (CT) images were obtained for 21 bladder cancer patients. These scans were matched to the rigid bony anatomy. For each patient, the main direction and magnitude of the tumor movement was determined by use of principle-component analysis. To study GTV shape changes, all GTVs were registered to the GTV in the planning CT scan, and the residual shape errors were determined by measurement of edge variations perpendicular to the median surface. Results: Gross tumor volume translations were largest in cranial-caudal and anterior-posterior direction (SD, 0.1 to {approx}0.9 cm). The translations were strongly correlated with the tumor location on the bladder wall. The average value of the local standard deviations of the GTV shape ranged from 0.1 to approximately 0.35 cm. Conclusions: Despite large differences in bladder filling, variations in GTV shape were small compared with variations in GTV position. Geometric uncertainties in the GTV position depended strongly on the tumor location on the bladder wall.

  20. Management of CNS tumors

    International Nuclear Information System (INIS)

    Griem, M.L.

    1987-01-01

    The treatment of tumors of the CNS has undergone a number of changes based on the impact of CT. The use of intraoperative US for the establishment of tumor location and tumor histology is demonstrated. MR imaging also is beginning to make an impact on the diagnosis and treatment of tumors of the CNS. Examples of MR images are shown. The authors then discuss the important aspects of tumor histology as it affects management and newer concepts in surgery, radiation, and chemotherapy on tumor treatment. The role of intraoperative placement of radioactive sources, the utilization of heavy particle radiation therapy, and the potential role of other experimental radiation therapy techniques are discussed. The role of hyperfractionated radiation and of neutrons and x-ray in a mixed-beam treatment are discussed in perspective with standard radiation therapy. Current chemotherapy techniques, including intraarterial chemotherapy, are discussed. The complications of radiation therapy alone and in combination with chemotherapy in the management of primary brain tumors, brain metastases, and leukemia are reviewed. A summary of the current management of pituitary tumors, including secreting pituitary adenomas and chromophobe adenomas, are discussed. The treatment with heavy particle radiation, transsphenoidal microsurgical removal, and combined radiotherapeutic and surgical management are considered. Tumor metastasis management of lesions of the brain and spinal cord are considered

  1. Bilateral carotid body tumor resection in a female patient

    Directory of Open Access Journals (Sweden)

    Alfred Burgess

    Full Text Available Introduction: Carotid body tumors also called carotid paragangliomas are rare neuroendocrine neoplasms derived from neural crest cells, approximately 3% of all paragangliomas occur in the head and neck area (Xiao and She, 2015; although they represent 65% of the head and neck paragangliomas (Georgiadis et al., 2008. Presentation of case: We present the therapeutic management of a 65-year-old woman with bilateral carotid body tumors. The patient presented to medical clinic for unrelated signs and symptoms of weight loss, dyspepsia, and epigastric pain. Physical examination showed bilateral non-tender neck masses for which imaging studies were ordered resulting in the diagnosis of bilateral carotid tumor. Surgical resection was staged with one week of distance between each tumor resection. Discussion: Carotid Body Tumors can arise from the paraganglia located within the adventitia of the medial aspect of the carotid bifurcation.Resection is the only curative treatment. Carotid body tumors resection represents a special challenge due to potential neurovascular complications. Conclusions: Surgical resection of carotid body tumors represents a special challenge to the surgeon because of the complex anatomical location of the tumor, including close relationship with the cranial nerves, involvement of the carotid vessels and large vascularization of the tumor. With the advance of diagnosis and improvement in surgical techniques as well as the understanding of biological behavior of tumors, surgical treatment has become a safer alternative for treating these tumors. Keywords: Carotid body tumor, Bilateral, Paraganglioma, Resection

  2. Bone fractures following external beam radiotherapy and limb-preservation surgery for lower extremity soft tissue sarcoma: relationship to irradiated bone length, volume, tumor location and dose.

    Science.gov (United States)

    Dickie, Colleen I; Parent, Amy L; Griffin, Anthony M; Fung, Sharon; Chung, Peter W M; Catton, Charles N; Ferguson, Peter C; Wunder, Jay S; Bell, Robert S; Sharpe, Michael B; O'Sullivan, Brian

    2009-11-15

    To examine the relationship between tumor location, bone dose, and irradiated bone length on the development of radiation-induced fractures for lower extremity soft tissue sarcoma (LE-STS) patients treated with limb-sparing surgery and radiotherapy (RT). Of 691 LE-STS patients treated from 1989 to 2005, 31 patients developed radiation-induced fractures. Analysis was limited to 21 fracture patients (24 fractures) who were matched based on tumor size and location, age, beam arrangement, and mean total cumulative RT dose to a random sample of 53 nonfracture patients and compared for fracture risk factors. Mean dose to bone, RT field size (FS), maximum dose to a 2-cc volume of bone, and volume of bone irradiated to >or=40 Gy (V40) were compared. Fracture site dose was determined by comparing radiographic images and surgical reports to fracture location on the dose distribution. For fracture patients, mean dose to bone was 45 +/- 8 Gy (mean dose at fracture site 59 +/- 7 Gy), mean FS was 37 +/- 8 cm, maximum dose was 64 +/- 7 Gy, and V40 was 76 +/- 17%, compared with 37 +/- 11 Gy, 32 +/- 9 cm, 59 +/- 8 Gy, and 64 +/- 22% for nonfracture patients. Differences in mean, maximum dose, and V40 were statistically significant (p = 0.01, p = 0.02, p = 0.01). Leg fractures were more common above the knee joint. The risk of radiation-induced fracture appears to be reduced if V40 Fracture incidence was lower when the mean dose to bone was lower mean FS for nonfracture patients.

  3. Manifestations of nonlinearity in fuel center thermocouple steady-state and transient data: implications for data analysis

    International Nuclear Information System (INIS)

    Lanning, D.D.; Barnes, B.O.; Williford, R.E.

    1979-01-01

    The interpretation and verification of fuel centerline thermocouple data are analyzed. Two new concepts are discussed along with their application to in-reactor data from IFA-432, a heavily instrumented six-rod Halden reactor test assembly sponsored by the Nuclear Regulatory Commission. The main ideas presented in this report are that: it is more useful to plot resistance versus power than simply to plot temperature versus power; and the response of the centerline temperature to a linear power decrease is correlated to the rod's current resistance-vs-power behavior. Thus, the resistance-vs-power measurement can be verified by performing a linear power decrease and by plotting the temperature response

  4. Tumors of germinal cells

    International Nuclear Information System (INIS)

    Plazas, Ricardo; Avila, Andres

    2002-01-01

    The tumors of germinal cells (TGC) are derived neoplasia of the primordial germinal cells that in the life embryonic migrant from the primitive central nervous system until being located in the gonads. Their cause is even unknown and they represent 95% of the testicular tumors. In them, the intention of the treatment is always healing and the diagnostic has improved thanks to the results of the handling multidisciplinary. The paper includes topics like their incidence and prevalence, epidemiology and pathology, clinic and diagnoses among other topics

  5. Biplane CT in sellar and parasellar tumors, (2)

    International Nuclear Information System (INIS)

    Sadamoto, Kazuhiko; Sakaki, Saburo; Matsuoka, Kenzo; Goishi, Junji; Sokabe, Takashi.

    1980-01-01

    Biplane CT images of 30 cases of sellar and parasellar tumors were studied. All 3 cases of meningioma were discovered by biplane CT (the diagnostic rate, 100%). As biplane CT could exclude partial volume effects, biplane CT images could demonstrate a fine structure and the position of parasellar or skull-base meningioma. As features of craniopharyngioma visualized on biplane CT images were variable, 7 of 9 cases of craniopharyngioma were detected by biplane CT (the diagnostic rate, 80%). When contrast enhancement on biplane CT images was marked, sometimes differencial diagnosis of craniopharyngioma and other suprasellar tumors was difficult. In all 18 cases of chromophobe adenoma, biplane CT images successfully demonstrated the location and extension of the tumors including cystic tumor (the diagnostic rate, 100%). In addition, 2 cases of giant aneurysm were presented in this study as examples of the differential diagnosis of pituitary and supraseller tumors. Biplane CT images showed mainly the location and the size of aneurysm as a mass lesion: therefore, cerebral angiography including vertebral arteriography was necessary for making an exact diagnosis of aneurysm. (Tsunoda, M)

  6. Diagnosis of pelvic wall tumor on multislice CT

    International Nuclear Information System (INIS)

    Zhang Keyun; Deng Lequn; Lei Hongwei

    2011-01-01

    Objective: To evaluate the value of multi-slice CT (MSCT) in diagnosing pelvic wall tumors. Methods: MSCT of 21 cases of pelvic wall tumors including metastasis (10), neurogenic tumor (5), chondrosarcoma (2), chordoma (1), aneurysmal bone cyst (1), giant cell tumor (1), and osteochondroma (1) was retrospectively analyzed. Results: CT appearances of pelvic wall tumors include bony destruction and soft tissue masses. Common features were bone destruction in metastasis, expansion of the neuroforamen in neurogenic tumor, pleomorphic calcification in chondrosarcoma, lower sacral vertebral location of chordoma, iliac crest bone destruction in giant cell tumor, cauliflower-like nodules in osteochondroma. Conclusion: MSCT with three-dimensional volume rendering demonstrates well the tumor shape, size, extent, internal structure and relationship with the surrounding organs to aid diagnosis of pelvic wall tumors. (authors)

  7. Neuroradiolological diagnosis and follow-up of brain tumors

    International Nuclear Information System (INIS)

    Kummer, R. von

    1997-01-01

    Primary tumors of the brain and cerebral metastases cause considerable morbidity and mortality. To assess the chance for cure and to develop a valid concept of treatment, the exact assessment of the tumor's location, of the tumor's borders and malignancy is essential. Today, neuroradiological examination mainly with magnetic resonance imaging (MRI) allows an almost histological diagnosis and description of the tumor's extent. MRI is as well useful for studying the patient's short- and long-term follow-up clinical course. This is illustrated by 3 case histories. (orig.)

  8. Awake craniotomy for tumor resection

    OpenAIRE

    Mohammadali Attari; Sohrab Salimi

    2013-01-01

    Surgical treatment of brain tumors, especially those located in the eloquent areas such as anterior temporal, frontal lobes, language, memory areas, and near the motor cortex causes high risk of eloquent impairment. Awake craniotomy displays major rule for maximum resection of the tumor with minimum functional impairment of the Central Nervous System. These case reports discuss the use of awake craniotomy during the brain surgery in Alzahra Hospital, Isfahan, Iran. A 56-year-old woman with le...

  9. Specific features of thermocouple calorimeter application for measurements of pulsed X-ray emission from plasma

    International Nuclear Information System (INIS)

    Gavrilov, V. V.; Fasakhov, I. K.

    2012-01-01

    It is shown that the accuracy of time-integrated measurements of pulsed X-ray emission from hot plasma with calibrated thermocouple calorimeters is mainly determined by two factors. The first and the most important factor is heating of the filter by the absorbed X-rays; as a result, the calorimeter measures the thermal radiation of the filter, which causes appreciable distortion of the temporal profile and amplitude of the recorded signal. The second factor is the dependence of the effective depth of X-ray absorption in the dielectric that covers the entrance window of the calorimeter on the energy of X-ray photons, i.e., on the recorded radiation spectrum. The results of model calculations of the calorimeter signal are compared with the experimental data.

  10. Evaluation of tumor-induced osteomalacia with 111In-pentetreotide scintigraphy.

    Science.gov (United States)

    Palot Manzil, Fathima Fijula; Bhambhvani, Pradeep G; O'Malley, Janis P

    2013-12-01

    In cases of nonhereditary osteomalacia associated with hypophosphatemia and inadequate response to vitamin D supplementation, one should consider the possibility of tumor-induced osteomalacia, a paraneoplastic syndrome caused by small mesenchymal tumors often found in obscure locations. We present a case of tumor-induced osteomalacia in which (111)In-pentetreotide scintigraphy aided in accurate localization of the culprit brachial plexus tumor and cure after resection.

  11. Computed tomographic diagnosis of parotid gland tumor

    International Nuclear Information System (INIS)

    Matsunaga, Hitoki; Nishimura, Tadao; Takasu, Akihiko; Yagizawa, Mikio; Suzuki, Akio

    1983-01-01

    Investigation with CT has been performed on 20 cases of parotid gland tumors. The intravenous contrast enhancement method was performed in all cases. Six cases were examined by CT and simultaneous sialography. The results were as follows: 1) If and when the margin of the tumor was indistinct and irregular, malignancy was suspected. However, it was difficult to diagnose malignancy by CT examination only. 2) CT for parotid gland tumor was effective in indentifying invasion of tumor into the parapharyngeal space and intracranial space. 3) CT with simultaneous sialography was very effective in locating the parotid gland tumor. 4) CT of axial sections for parotid gland tumor was more reliable if coronaly sections are taken together. 5) CT of malignant and benign tumors were diffusely enhanced by the intravenous contrast enhancement method. However, this was not an indispensable method. (author)

  12. An accurate algorithm to match imperfectly matched images for lung tumor detection without markers.

    Science.gov (United States)

    Rozario, Timothy; Bereg, Sergey; Yan, Yulong; Chiu, Tsuicheng; Liu, Honghuan; Kearney, Vasant; Jiang, Lan; Mao, Weihua

    2015-05-08

    In order to locate lung tumors on kV projection images without internal markers, digitally reconstructed radiographs (DRRs) are created and compared with projection images. However, lung tumors always move due to respiration and their locations change on projection images while they are static on DRRs. In addition, global image intensity discrepancies exist between DRRs and projections due to their different image orientations, scattering, and noises. This adversely affects comparison accuracy. A simple but efficient comparison algorithm is reported to match imperfectly matched projection images and DRRs. The kV projection images were matched with different DRRs in two steps. Preprocessing was performed in advance to generate two sets of DRRs. The tumors were removed from the planning 3D CT for a single phase of planning 4D CT images using planning contours of tumors. DRRs of background and DRRs of tumors were generated separately for every projection angle. The first step was to match projection images with DRRs of background signals. This method divided global images into a matrix of small tiles and similarities were evaluated by calculating normalized cross-correlation (NCC) between corresponding tiles on projections and DRRs. The tile configuration (tile locations) was automatically optimized to keep the tumor within a single projection tile that had a bad matching with the corresponding DRR tile. A pixel-based linear transformation was determined by linear interpolations of tile transformation results obtained during tile matching. The background DRRs were transformed to the projection image level and subtracted from it. The resulting subtracted image now contained only the tumor. The second step was to register DRRs of tumors to the subtracted image to locate the tumor. This method was successfully applied to kV fluoro images (about 1000 images) acquired on a Vero (BrainLAB) for dynamic tumor tracking on phantom studies. Radiation opaque markers were

  13. Attachment of lead wires to thin film thermocouples mounted on high temperature materials using the parallel gap welding process

    Science.gov (United States)

    Holanda, Raymond; Kim, Walter S.; Pencil, Eric; Groth, Mary; Danzey, Gerald A.

    1990-01-01

    Parallel gap resistance welding was used to attach lead wires to sputtered thin film sensors. Ranges of optimum welding parameters to produce an acceptable weld were determined. The thin film sensors were Pt13Rh/Pt thermocouples; they were mounted on substrates of MCrAlY-coated superalloys, aluminum oxide, silicon carbide and silicon nitride. The entire sensor system is designed to be used on aircraft engine parts. These sensor systems, including the thin-film-to-lead-wire connectors, were tested to 1000 C.

  14. Beyond the GIST: Mesenchymal Tumors of the Stomach

    Science.gov (United States)

    Menias, Christine O.; Gaballah, Ayman H.; Shroff, Stuti; Taggart, Melissa W.; Garg, Naveen; Elsayes, Khaled M.

    2013-01-01

    Intramural gastric masses arise in the wall of the stomach (generally within the submucosa or muscularis propria), often with intact overlying mucosa. These tumors are typically mesenchymal in origin and have overlapping radiologic appearances. A combination of features such as location, attenuation, enhancement, and growth pattern may suggest one diagnosis over another. Gastrointestinal stromal tumors (GISTs) account for the majority of intramural tumors and can vary widely in appearance, from small intraluminal lesions to exophytic masses that protrude into the peritoneal cavity, commonly with areas of hemorrhage or necrosis. A well-circumscribed mass measuring −70 to −120 HU is a lipoma. Leiomyomas usually manifest as low-attenuation masses at the gastric cardia. Homogeneous attenuation is a noteworthy characteristic of schwannomas, particularly for larger lesions that might otherwise be mistaken for GISTs. A hypervascular mass in the antrum is a common manifestation of glomus tumors. Hemangiomas are also hypervascular but often manifest in childhood. Inflammatory fibroid polyps usually arise as a polypoid mass in the antrum. Inflammatory myofibroblastic tumors are infiltrative neoplasms with a propensity for local recurrence. Plexiform fibromyxomas are rare, usually antral tumors. Carcinoid tumors are epithelial in origin, but often submucosal in location, and therefore should be distinguished from other intramural lesions. Multiple carcinoid tumors are associated with hypergastrinemia, either in the setting of chronic atrophic gastritis or Zollinger-Ellison syndrome. Sporadic solitary carcinoid tumors not associated with hypergastrinemia have a higher rate of metastasis. Histopathologic analysis, including immunohistochemistry, is usually required for diagnosis of intramural masses. © RSNA, 2013 PMID:24108557

  15. Uniformity index measurement technology using thermocouples to improve performance in urea-selective catalytic reduction systems

    Science.gov (United States)

    Park, Sangki; Oh, Jungmo

    2018-05-01

    The current commonly used nitrogen oxides (NOx) emission reduction techniques employ hydrocarbons (HCs), urea solutions, and exhaust gas emissions as the reductants. Two of the primary denitrification NOx (DeNOx) catalyst systems are the HC-lean NOx trap (HC-LNT) catalyst and urea-selective catalytic reduction (urea-SCR) catalyst. The secondary injection method depends on the type of injector, injection pressure, atomization, and spraying technique. In addition, the catalyst reaction efficiency is directly affected by the distribution of injectors; hence, the uniformity index (UI) of the reductant is very important and is the basis for system optimization. The UI of the reductant is an indicator of the NOx conversion efficiency (NCE), and good UI values can reduce the need for a catalyst. Therefore, improving the UI can reduce the cost of producing a catalytic converter, which are expensive due to the high prices of the precious metals contained therein. Accordingly, measurement of the UI is an important process in the development of catalytic systems. Two of the commonly used methods for measuring the reductant UI are (i) measuring the exhaust emissions at many points located upstream/downstream of the catalytic converter and (ii) acquisition of a reductant distribution image on a section of the exhaust pipe upstream of the catalytic converter. The purpose of this study is to develop a system and measurement algorithms to measure the exothermic response distribution in the exhaust gas as the reductant passes through the catalytic converter of the SCR catalyst system using a set of thermocouples downstream of the SCR catalyst. The system is used to measure the reductant UI, which is applied in real-time to the actual SCR system, and the results are compared for various types of mixtures for various engine operating conditions and mixer types in terms of NCE.

  16. Hemorragia digestiva por tumor estromal gástrico

    Directory of Open Access Journals (Sweden)

    Francisco de Souza Consolo

    Full Text Available Gastrointestinal stromal tumors account for 0.1 to 3% of all resected gastric tumors and are the most common submucosal mass found in the stomach. Preoperative diagnosis is often difficult; consequently surgery is the best and only option on most cases. There are studies with different surgery techniques based on tumors location. The reported case led us at literature review with the intent of establishing preoperative diagnosis, therapeutic strategies and prognosis.

  17. [Risk factors for malignant evolution of gastrointestinal stromal tumors].

    Science.gov (United States)

    Andrei, S; Andrei, Adriana; Tonea, A; Andronesi, D; Becheanu, G; Dumbravă, Mona; Pechianu, C; Herlea, V; Popescu, I

    2007-01-01

    Gastrointestinal stromal tumors are the most frequent non-epithelial digestive tumors, being classified in the group of primitive mesenchymal tumors of the digestive tract. These tumors have a non predictable evolution and where stratified regarding the risk for malignant behavior in 4 categories: very low risk, low risk, intermediate risk and high risk. We performed a retrospective non randomised study including the patients with gastrointestinal stromal tumors treated in the Department of General Surgery and Liver Transplantation of Fundeni Clinical Institute in the period January 2002 - June 2007, to define the epidemiological, clinico-paraclinical, histological and especially evolutive features of the gastrointestinal stromal tumors from this group, with a special regard to the risk factors for their malignant behavior. The most important risk factors in gastrointestinal stromal tumors are the tumor size and the mitotic index, based on them being realised the classification of Fletcher in the 4 risk categories mentioned above. In our group all the local advanced or metastatic gastrointestinal stromal tumors, regardless of their location, were classified in the group of high risk for the malignant behavior. The gastric location and the epithelioid type were positive prognostic factors, and the complete resection of the tumor, an other important positive prognostic feature, was possible in about 80% of the cases, probably because the gastrointestinal stromal tumors in our study were diagnosed in less advanced evolutive situations, only about one third being metastatic and about 14% being locally advanced at the time of diagnose. The association with other neoplasias was in our cases insignificant, only 5% of the patients presenting concomitant malignant digestive tumors and 7.6% intraabdominal benign tumors. Gastrointestinal stromal tumors remain a challenge for the medical staff, regarding their diagnose and therapeutical management, the stratification of the

  18. Surgical treatment of tumor-induced osteomalacia: a retrospective review of 40 cases with extremity tumors.

    Science.gov (United States)

    Sun, Zhi-jian; Jin, Jin; Qiu, Gui-xing; Gao, Peng; Liu, Yong

    2015-02-26

    Tumor-induced osteomalacia (TIO) is a rare syndrome typically caused by mesenchymal tumors. It has been shown that complete tumor resection may be curative. However, to our knowledge, there has been no report of a large cohort to exam different surgical approaches. This study was aimed to assess outcomes of different surgical options of patients with tumor-induced osteomalacia at a single institution. Patients with extremity tumors treated in our hospital from January, 2004 to July, 2012 were identified. The minimum follow-up period was 12 months. Patient's demography, tumor location, preoperative preparation, type of surgeries were summarized, and clinical outcomes were recorded. Successful treatment was defined as significant symptom improvement, normal serum phosphorus and significant improvement or normalization of bone mineral density at the last follow-up. Differences between patients with soft tissue tumors and bone tumors were compared. There were 40 (24 male and 16 female) patients identified, with an average age of 44 years. The tumors were isolated in either soft tissue (25 patients) or bone (12 patients) and combined soft tissue and bone invasion was observed in 3 patients. For the primary surgery, tumor resection and tumor curettage were performed. After initial surgical treatment, six patients then received a second surgery. Four patients were found to have malignant tumors base on histopathology. With a minimum follow-up period of 12 months, 80% of patients (32/40) were treated successfully, including 50% of patients (2/4) with malignant tumors. Compared to patients with bone tumor, surgical results were better in patient with soft tissue tumor. Surgical treatment was an effective way for TIO. Other than tumor curettage surgery, tumor resection is the preferred options for these tumors.

  19. Preparation and Thermoelectric Characteristics of ITO/PtRh:PtRh Thin Film Thermocouple.

    Science.gov (United States)

    Zhao, Xiaohui; Wang, Hongmin; Zhao, Zixiang; Zhang, Wanli; Jiang, Hongchuan

    2017-12-15

    Thin film thermocouples (TFTCs) can provide more precise in situ temperature measurement for aerospace propulsion systems without disturbance of gas flow and surface temperature distribution of the hot components. ITO/PtRh:PtRh TFTC with multilayer structure was deposited on alumina ceramic substrate by magnetron sputtering. After annealing, the TFTC was statically calibrated for multiple cycles with temperature up to 1000 °C. The TFTC with excellent stability and repeatability was realized for the negligible variation of EMF in different calibration cycles. It is believed that owing to oxygen diffusion barriers by the oxidation of top PtRh layer and Schottky barriers formed at the grain boundaries of ITO, the variation of the carrier concentration of ITO film is minimized. Meanwhile, the life time of TFTC is more than 30 h in harsh environment. This makes ITO/PtRh:PtRh TFTC a promising candidate for precise surface temperature measurement of hot components of aeroengines.

  20. A comparison of tumor motion characteristics between early stage and locally advanced stage lung cancers

    International Nuclear Information System (INIS)

    Yu, Z. Henry; Lin, Steven H.; Balter, Peter; Zhang Lifei; Dong Lei

    2012-01-01

    Purpose: With the increasing use of conformal radiation therapy methods for non-small cell lung cancer (NSCLC), it is necessary to accurately determine respiratory-induced tumor motion. The purpose of this study is to analyze and compare the motion characteristics of early and locally advanced stage NSCLC tumors in a large population and correlate tumor motion with position, volume, and diaphragm motion. Methods and materials: A total of 191 (94 early stage, 97 locally advanced) non-small cell lung tumors were analyzed for this study. Each patient received a four-dimensional CT scan prior to receiving radiation treatment. A soft-tissue-based rigid registration algorithm was used to track the tumor motion. Tumor volumes were determined based on the gross tumor volume delineated by physicians in the end of expiration phase. Tumor motion characteristics were correlated with their standardized tumor locations, lobe location, and clinical staging. Diaphragm motion was calculated by subtracting the diaphragm location between the expiration and the inspiration phases. Results: Median, max, and 95th percentile of tumor motion for early stage tumors were 5.9 mm, 31.0 mm, and 20.0 mm, which were 1.2 mm, 12 mm, and 7 mm more than those in locally advanced NSCLC, respectively. The range of motion at 95th percentile is more than 50% larger in early stage lung cancer group than in the locally advanced lung cancer group. Early stage tumors in the lower lobe showed the largest motion with a median motion of 9.2 mm, while upper/mid-lobe tumors exhibited a median motion of 3.3 mm. Tumor volumes were not correlated with motion. Conclusion: The range of tumor motion differs depending on tumor location and staging of NSCLC. Early stage tumors are more mobile than locally advanced stage NSCLC. These factors should be considered for general motion management strategies when 4D simulation is not performed on individual basis.

  1. [Surgical management of minor salivary gland tumors].

    Science.gov (United States)

    Zhou, Liang; Chen, Xiaoling; Huang, Weiting; Li, Kelan; Zhang, Xiaotong; Wang, Wei

    2007-11-01

    To study the clinical features of minor salivary gland tumors and to discuss the treatment modalities for these tumors. Retrospective analysis of 54 cases with minor salivary gland tumor operated in our hospital from 1997 to 2004. Among 54 cases with minor salivary gland tumors in this series, 16 patients lost of follow up. Among the remaining 38 patients, 2 patients with nasal cavity adenoid cystic carcinoma died of tumor recurrence 2 and 3 years after the surgery respectively, one patient with laryngeal myoepithelial carcinoma died of tumor recurrence 3 years after the surgery and one patient with paranasal sinus mucoepidermoid carcinoma died of recurrence 17 months after the surgery. Two patients with paranasal sinus adenoid cystic carcinoma recurred after the primary surgery and were survived without tumor after salvage surgery. The other patients survived with no tumor recurrence. While different histopathology of minor salivary gland tumors were found in this group, malignant tumors were predominant, accounting for 81.4%. The choice of treatment for minor salivary gland tumors depends upon the location and the histopathology of the tumors. The treatment policy for benign tumors is simple tumor excision, while that for malignant tumors is surgery combined with pre- or post-operative radiation therapy. Complete surgical resection of tumor masses and tumor free margin is essential for successful treatment of malignant minor salivary gland tumors.

  2. Vertebral bony tumor of giant cells

    International Nuclear Information System (INIS)

    Jaramillo Carling, Eduardo

    2005-01-01

    This is a report of a 37 years old, masculine patient, in whom a unique primary bone injury was demonstrated, located at T-11, diagnosed as a giant cells tumor (osteoclastoma). Location is described in the literature as unusual. The clinical presentation of the injury is described, as the initial radiological studies and magnetic resonance images 8 years after surgical treatment, with no neoplasic recurrences. The medical literature of these primary bone injuries and its treatment was also reviewed. Objectives: to present a patient with an unusual extramedullar tumor injury, of primary bone origin, benign, treated surgically and who has a post surgical follow-up of 8 years. Local tumor recurrence and not pulmonary metastasis was demonstrated. The medical literature of this bone pathology that affects the spine in an infrequent manner, was also reviewed, specially the related to medical, surgical and radio-therapeutic treatments. Methodology: the clinical history of the patient is described, who was successfully operated, because the expansive tumor was totally drawn out, without neurological injury; inter operating or post-operating vertebral instability was not observed or diagnosed. The patient was controlled in periodic form, with last medical checkup and of magnetic resonance 8 years after the surgery. The medical publications existing are reviewed

  3. Imaging of benign tumors of the osseous spine

    OpenAIRE

    Riahi, Hend; Mechri, Meriem; Barsaoui, Maher; Bouaziz, Mouna; Vanhoenacker, Filip; Ladeb, Mohamed

    2018-01-01

    Abstract: The purpose of this paper is to present an overview of the imaging features of the most prevalent benign bone tumors involving the spine. Benign tumors of the osseous spine account approximately for 1% of all primary skeletal tumors. Many lesions exhibit characteristic radiologic features. In addition to age and location of the lesion, radiographs are an essential step in the initial detection and characterization but are limited to complex anatomy and superposition. CT and MR imagi...

  4. Cryospectrophotometric determination of tumor intravascular oxyhemoglobin saturations: dependence on vascular geometry and tumor growth.

    Science.gov (United States)

    Fenton, B M; Rofstad, E K; Degner, F L; Sutherland, R M

    1988-12-21

    To delineate the complex relationships between overall tumor oxygenation and vascular configuration, intravascular oxyhemoglobin (HbO2) saturation distributions were measured with cryospectrophotometric techniques. Four factors related to vascular morphometry and tumor growth were evaluated: a) vessel diameter, b) distance of vessel from the tumor surface, c) tumor volume, and d) vascular density. To measure intertumor heterogeneity, two murine sarcomas (RIF-1 and KHT) and two human ovarian carcinoma xenografts (OWI and MLS) were utilized. In contrast to skeletal muscle, a preponderance of very low HbO2 saturations was observed for both large and small tumors of all lines. Saturations up to about 90% were also generally present, however, even in very large tumors. Variations in vascular configuration were predominantly tumor-line dependent rather than due to inherent characteristics of the host vasculature, and widely disparate HbO2 distributions were found for alternate lines implanted in identical host mice. Although peripheral saturations remained fairly constant with tumor growth, HbO2 values were markedly lower for vessels nearer the tumor center and further decreased with increasing tumor volume. HbO2 saturations did not change substantially with increasing vascular density (except for KHT tumors), although density did decrease with increasing distance from tumor surface. Combined effects of vessel diameter, tumor volume, and vessel location on HbO2 saturations were complex and varied markedly with both tumor line and vessel class. For specific classes, HbO2 distributions correlated closely with radiobiological hypoxic fractions, i.e., for tumor lines in which hypoxic fraction increased substantially with tumor volume, corresponding HbO2 values decreased, while for lines in which hypoxic fraction remained constant, HbO2 values also were unchanged. Although these trends may also be a function of differing oxygen consumption rates between tumor lines

  5. Imaging tumors of the patella

    Energy Technology Data Exchange (ETDEWEB)

    Casadei, R., E-mail: roberto.casadei@ior.it [Department of Orthopaedic Oncology, Istituto Ortopedico Rizzoli, Bologna (Italy); Kreshak, J., E-mail: j.kreshak@yahoo.com [Department of Orthopaedic Oncology, Istituto Ortopedico Rizzoli, Bologna (Italy); Department of Pathology, Istituto Ortopedico Rizzoli, Bologna (Italy); Rinaldi, R. [Department of Radiology, Istituto Ortopedico Rizzoli, Bologna (Italy); Rimondi, E., E-mail: eugenio.rimondi@ior.it [Department of Radiology, Istituto Ortopedico Rizzoli, Bologna (Italy); Bianchi, G., E-mail: giuseppe.bianchi@ior.it [Department of Orthopaedic Oncology, Istituto Ortopedico Rizzoli, Bologna (Italy); Alberghini, M., E-mail: marco.alberghini@ior.it [Department of Pathology, Istituto Ortopedico Rizzoli, Bologna (Italy); Ruggieri, P. [Department of Orthopaedic Oncology, Istituto Ortopedico Rizzoli, Bologna (Italy); Vanel, D., E-mail: daniel.vanel@ior.it [Department of Radiology, Istituto Ortopedico Rizzoli, Bologna (Italy); Department of Pathology, Istituto Ortopedico Rizzoli, Bologna (Italy)

    2013-12-01

    Background: Patellar tumors are rare; only a few series have been described in the literature and radiographic diagnosis can be challenging. We reviewed all patellar tumors at one institution and reviewed the literature. Materials and methods: In an evaluation of the database at one institution from 1916 to 2009, 23,000 bone tumors were found. Of these, 41 involved the patella. All had imaging studies and microscopic diagnostic confirmation. All medical records, imaging studies, and pathology were reviewed. Results: There were 15 females and 26 males, ranging from 8 to 68 years old (average 30). There were 30 benign tumors; eight giant cell tumors, eight chondroblastomas, seven osteoid osteomas, two aneurysmal bone cysts, two ganglions, one each of chondroma, exostosis, and hemangioma. There were 11 malignant tumors: five hemangioendotheliomas, three metastases, one lymphoma, one plasmacytoma, and one angiosarcoma. Conclusion: Patellar tumors are rare and usually benign. As the patella is an apophysis, the most frequent lesions are giant cell tumor in the adult and chondroblastoma in children. Osteoid osteomas were frequent in our series and easily diagnosed. Metastases are the most frequent malignant diagnoses in the literature; in our series malignant vascular tumors were more common. These lesions are often easily analyzed on radiographs. CT and MR define better the cortex, soft tissue extension, and fluid levels. This study presents the imaging patterns of the more common patellar tumors in order to help the radiologist when confronted with a lesion in this location.

  6. CT findings of malignant nasal cavity tumors

    International Nuclear Information System (INIS)

    Ku, Young Mi; Chun, Kyung Ah; Choi, Kyu Ho; Yu, Won Jong; Kim, Young Joo; Kim, Sung Hoon; Park, Seog Hee; Shinn, Kyung Sub

    1997-01-01

    To evaluate the CT findings of malignant nasal cavity tumors. Retrospective analysis was performed on 20 patients with pathologically-proven malignant nasal cavity tumors. Using CT, we analysed their location, extent of bone destruction and of involvement of adjacent structures, and enhancing pattern. A total of 20 cases included nine squamous cell carcinomas, three olfactory neuroblastomas, three lymphomas, two polymorphic reticulosis, one adenoid cystic carcinoma, one undifferentiated carcinoma and one metastasis from renal cell carcinoma. All cases except one adenoid cystic carcinoma and one squamous cell carcinoma revealed bone destruction or erosion. Aggressive bone destruction and irregular enhancement were seen in eight cases of squamous cell carcinoma, seven cases of which showed involvement of the adjacent paranasal sinuses, nasopharynx, and orbit. Olfactory neuroblastomas were centered in the superior nasal cavity and the adjacent ethmoid sinus, and erosion or destruction of the cribriform plate had occurred. Lymphomas showed bilateral involvement, with uniform contrast enhancement. Polymorphic reticuloses showed perforation or erosion of the nasal septum, with bilateral involvement of the nasal cavity. The location, presence of bone destruction, involvement of adjacent structures, and enhancement pattern of tumor on CT can be helpful for the differential diagnosis of malignant nasal cavity tumors

  7. Carcinoma basocelular em localizações incomuns Basal cell carcinoma in unusual locations

    Directory of Open Access Journals (Sweden)

    Ane Beatriz Mautari Niwa

    2006-10-01

    Full Text Available Os autores apresentam cinco pacientes que desenvolveram carcinomas basocelulares em locais incomuns de ocorrência desse tumor. O objetivo é relatar a raridade topográfica da neoplasia cutânea e discutir o conceito de localização incomum para o carcinoma basocelular.The authors present five patients who develop basal cell carcinomas in sites this tumor rarely occurs. The aim is to report the rare location of this frequent cutaneous malignancy and to briefly discuss the concept of unusual location of basal cell carcinoma.

  8. Diagnosis and treatment of ampullary tumors

    Directory of Open Access Journals (Sweden)

    YIN Tao

    2017-02-01

    Full Text Available Ampullary tumors mainly manifest as obstructive jaundice and ampullary mass in clinical practice and are difficult to be identified in early stage due to a complex structure of the anatomical site, a deep location, and hidden symptoms. Sometimes a qualitative diagnosis cannot be made. Based on the experience in the treatment of ampullary tumors for many years in our center, this article summarizes the features of ampullary tumors from the aspects of clinical manifestations, diagnosis, treatment, and prognosis, especially the issues regarding imaging evaluation of ampullary tumors, selection of surgical procedure, and prognosis. An early diagnosis is the key to the treatment of ampullary tumors, and early identification and treatment of lesions have great impacts on patients′ prognosis. Accurate preoperative imaging evaluation, a professional diagnosis and treatment team, accurate preoperative and intraoperative pathological analysis, and implementation of reasonable therapeutic strategy are the key to patients′ recovery.

  9. The CD4/CD8 ratio of tumor-infiltrating lymphocytes at the tumor-host interface has prognostic value in triple-negative breast cancer.

    Science.gov (United States)

    Wang, Kai; Shen, Tiansheng; Siegal, Gene P; Wei, Shi

    2017-11-01

    Compelling evidence has demonstrated the prognostic value of tumor-infiltrating lymphocytes (TILs), especially in triple-negative breast cancer (TNBC). However, only a limited number of studies to investigate the importance of the subsets of T cells in TILs have been carried out, less so the significance of the location of these TILs. In this study, we explored in a cohort of 42 consecutive TNBC cases the prognostic significance of TIL subsets at the tumor-host interface (within 1 high-power field [0.5 mm] of the invasive front) and compared them with TILs within the intratumoral stroma. Given the reported importance of TILs in HER2-overexpressing breast cancer, a subset of such tumors was also included for comparison. The range was wide in both locations; nevertheless, the mean CD4 + and CD8 + T cell count was significantly higher at the tumor-host interface than that found within the intratumoral stroma (both P<.0001). The number of CD4 + or CD8 + T cells at either location was not significantly associated with distant relapse-free or overall survival. However, the CD4/CD8 ratio at the tumor-host interface was significantly associated with both relapse-free survival (hazard ratio 0.2, P=.002) and overall survival (hazard ratio 0.13, P=.002), whereas this association was not seen for the CD4/CD8 ratio within the intratumoral stroma. As expected, both tumor size and nodal status were significantly associated with survival outcomes. The findings further support the contention that TILs, as markers of regional immune escape, are of prognostic importance in TNBC progression and that the CD4/CD8 ratio of TILs at the tumor-host interface plays a distinctive role, thus appearing to be of clinical relevance. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Bone Fractures Following External Beam Radiotherapy and Limb-Preservation Surgery for Lower Extremity Soft Tissue Sarcoma: Relationship to Irradiated Bone Length, Volume, Tumor Location and Dose

    International Nuclear Information System (INIS)

    Dickie, Colleen I.; Parent, Amy L.; Griffin, Anthony M.; Fung, Sharon; Chung, Peter W.M.; Catton, Charles N.; Ferguson, Peter C.; Wunder, Jay S.; Bell, Robert S.; Sharpe, Michael B.; O'Sullivan, Brian

    2009-01-01

    Purpose: To examine the relationship between tumor location, bone dose, and irradiated bone length on the development of radiation-induced fractures for lower extremity soft tissue sarcoma (LE-STS) patients treated with limb-sparing surgery and radiotherapy (RT). Methods and Materials: Of 691 LE-STS patients treated from 1989 to 2005, 31 patients developed radiation-induced fractures. Analysis was limited to 21 fracture patients (24 fractures) who were matched based on tumor size and location, age, beam arrangement, and mean total cumulative RT dose to a random sample of 53 nonfracture patients and compared for fracture risk factors. Mean dose to bone, RT field size (FS), maximum dose to a 2-cc volume of bone, and volume of bone irradiated to ≥40 Gy (V40) were compared. Fracture site dose was determined by comparing radiographic images and surgical reports to fracture location on the dose distribution. Results: For fracture patients, mean dose to bone was 45 ± 8 Gy (mean dose at fracture site 59 ± 7 Gy), mean FS was 37 ± 8 cm, maximum dose was 64 ± 7 Gy, and V40 was 76 ± 17%, compared with 37 ± 11 Gy, 32 ± 9 cm, 59 ± 8 Gy, and 64 ± 22% for nonfracture patients. Differences in mean, maximum dose, and V40 were statistically significant (p = 0.01, p = 0.02, p = 0.01). Leg fractures were more common above the knee joint. Conclusions: The risk of radiation-induced fracture appears to be reduced if V40 <64%. Fracture incidence was lower when the mean dose to bone was <37 Gy or maximum dose anywhere along the length of bone was <59 Gy. There was a trend toward lower mean FS for nonfracture patients.

  11. Local and systemic tumor immune dynamics

    Science.gov (United States)

    Enderling, Heiko

    Tumor-associated antigens, stress proteins, and danger-associated molecular patterns are endogenous immune adjuvants that can both initiate and continually stimulate an immune response against a tumor. In retaliation, tumors can hijack intrinsic immune regulatory programs that are intended to prevent autoimmune disease, thereby facilitating continued growth despite the activated antitumor immune response. In metastatic disease, this ongoing tumor-immune battle occurs at each site. Adding an additional layer of complexity, T cells activated at one tumor site can cycle through the blood circulation system and extravasate in a different anatomic location to surveil a distant metastasis. We propose a mathematical modeling framework that incorporates the trafficking of activated T cells between metastatic sites. We extend an ordinary differential equation model of tumor-immune system interactions to multiple metastatic sites. Immune cells are activated in response to tumor burden and tumor cell death, and are recruited from tumor sites elsewhere in the body. A model of T cell trafficking throughout the circulatory system can inform the tumor-immune interaction model about the systemic distribution and arrival of T cells at specific tumor sites. Model simulations suggest that metastases not only contribute to immune surveillance, but also that this contribution varies between metastatic sites. Such information may ultimately help harness the synergy of focal therapy with the immune system to control metastatic disease.

  12. Biological Effects of Nonionizing Electromagnetic Radiation. Volume IV. Number 3.

    Science.gov (United States)

    1980-03-01

    29- gauge thermocouples were inserted into the tumor center and in its deepest aspect. Thermocouples 6429 EMPLOYMENT OF MAGNETOTHERAPY IN THE CON...hyperthermia generally ranged from slight to severe erythema. Although good data were difficult to The therapeutic effectiveness of magnetotherapy obtain...subcutaneous tissue can be heated to 41-42 C for received magnetotherapy in addition to the con- periods up to 2 hr after RT without any evidence of I

  13. Pathological Location of Cranial Nerves in Petroclival Lesions: How to Avoid Their Injury during Anterior Petrosal Approach.

    Science.gov (United States)

    Borghei-Razavi, Hamid; Tomio, Ryosuke; Fereshtehnejad, Seyed-Mohammad; Shibao, Shunsuke; Schick, Uta; Toda, Masahiro; Yoshida, Kazunari; Kawase, Takeshi

    2016-02-01

    Objectives  Numerous surgical approaches have been developed to access the petroclival region. The Kawase approach, through the middle fossa, is a well-described option for addressing cranial base lesions of the petroclival region. Our aim was to gather data about the variation of cranial nerve locations in diverse petroclival pathologies and clarify the most common pathologic variations confirmed during the anterior petrosal approach. Method  A retrospective analysis was made of both videos and operative and histologic records of 40 petroclival tumors from January 2009 to September 2013 in which the Kawase approach was used. The anatomical variations of cranial nerves IV-VI related to the tumor were divided into several location categories: superior lateral (SL), inferior lateral (IL), superior medial (SM), inferior medial (IM), and encased (E). These data were then analyzed taking into consideration pathologic subgroups of meningioma, epidermoid, and schwannoma. Results  In 41% of meningiomas, the trigeminal nerve is encased by the tumor. In 38% of the meningiomas, the trigeminal nerve is in the SL part of the tumor, and it is in 20% of the IL portion of the tumor. In 38% of the meningiomas, the trochlear nerve is encased by the tumor. The abducens nerve is not always visible (35%). The pathologic nerve pattern differs from that of meningiomas for epidermoid and trigeminal schwannomas. Conclusion  The pattern of cranial nerves IV-VI is linked to the type of petroclival tumor. In a meningioma, tumor origin (cavernous, upper clival, tentorial, and petrous apex) is the most important predictor of the location of cranial nerves IV-VI. Classification of four subtypes of petroclival meningiomas using magnetic resonance imaging is very useful to predict the location of deviated cranial nerves IV-VI intraoperatively.

  14. Atypical teratoid/rhabdoid tumor: an unusual presentation

    International Nuclear Information System (INIS)

    Gandhi, Chirag D.; Krieger, Mark D.; McComb, J. Gordon

    2004-01-01

    Atypical teratoid/ rhabdoid tumor (AT/RT) of the central nervous system is a rare, highly aggressive malignancy of infancy. Although it is reported infrequently in the literature, it has often been histologically confused with a primitive neuroectodermal tumor (PNET)/medulloblastoma (MB) but has a much worse prognosis. We present an infant with two AT/RT tumors, one suprasellar in location and the other within the vermis without evidence of tumor elsewhere. What makes this case unusual is that there were two separate lesions in different cranial compartments, with no evidence of subarachnoid seeding. In addition, the lesions had different magnetic resonance imaging (MRI) characteristics even though they were histologically the same. (orig.)

  15. Controversies in presacral tumors management

    Directory of Open Access Journals (Sweden)

    Nidal Issa

    2017-10-01

    Full Text Available Presacral tumors are rare lesions of the retrorectal space that can present diagnostic and therapeutic difficulty because of their anatomic location and the different tissue types and etiology. Although the diagnosis and management of these tumors has evolved in recent years, several points still to be addressed in order to improve perioperative diagnosis and treatment. In the upcoming we will try to highlight some controversial points; the pre-operative biopsies, neoadjuvant therapy, the necessity of surgery and the role of minimally invasive surgeries of presacral tumors. Resumo: Tumores pré-sacrais são lesões raras do espaço retrorretal que podem trazer dificuldades diagnósticas e terapêuticas por causa de sua localização anatômica e também pelos diferentes tipos de tecidos e etiologia. Embora nos últimos anos o diagnóstico e tratamento desses tumores tenham evoluído, diversos pontos ainda devem ser estudados com vistas à melhora do diagnóstico e tratamento no perioperatório. Mais adiante, tentaremos esclarecer alguns pontos controversos; biópsias pré-operatórias, terapia neoadjuvante, a necessidade de cirurgia e o papel das cirurgias minimamente invasivas para os tumores pré-sacrais. Keywords: Presacral tumor, Preoperative biopsy, Neoadjuvant therapy, Palavras-chave: Tumor pré-sacral, Biópsia pré-operatória, Terapia neoadjuvante

  16. Management of hemorrhage in gastrointestinal stromal tumors: a review.

    Science.gov (United States)

    Liu, Qi; Kong, Fanmin; Zhou, Jianping; Dong, Ming; Dong, Qi

    2018-01-01

    Gastrointestinal stromal tumors (GISTs) are relatively common mesenchymal tumors. They originate from the wall of hollow viscera and may be found in any part of the digestive tract. The prognosis of patients with stromal tumors depends on various risk factors, including size, location, presence of mitotic figures, and tumor rupture. Emergency surgery is often required for stromal tumors with hemorrhage. The current literature suggests that stromal tumor hemorrhage indicates poor prognosis. Although the optimal treatment options for hemorrhagic GISTs are based on surgical experience, there remains controversy with regard to optimum postoperative management as well as the classification of malignant potential. This article reviews the biological characteristics, diagnostic features, prognostic factors, treatment, and postoperative management of GISTs with hemorrhage.

  17. Carcinoids tumors of the digestive tract

    International Nuclear Information System (INIS)

    Carvalho, S.M.R. de; Prais, M.; Matushita, J.P.K.; Matushita, J.S.

    1989-01-01

    Eighteen cases of carcinoid tumors in the digestive tract have been analyzed. They have been selected at Hospital dos Servidores do Estado do Rio de Janeiro, taking into account patients, age and sex, lesions' location and size, clinical manifestations, presence of metastases as well as a classical carcinoid syndrome establisment. Carcinoid tumors come from the digestive tract 'argenta fim'' cells, the ones which produce endocrines. Such endocrines are responsible for a great number of clinical manifestations. The classical syndrome is directly related to the presence of hepatic metastases. The authors propose to correlate what has been found with descriptions in medical literature emphasizing the radiographic aspects which have been observed. A frequent ''apendicular'' location and the difficulty of giving a precise diagnosis before surgery is also emphasized. (author) [pt

  18. Pituitary gland tumors; Hypophysentumoren

    Energy Technology Data Exchange (ETDEWEB)

    Jesser, J.; Schlamp, K.; Bendszus, M. [Radiologische Klinik, Universitaetsklinikum Heidelberg, Abteilung fuer Neuroradiologie, Heidelberg (Germany)

    2014-10-15

    This article gives an overview of the most common tumors of the pituitary gland and the differential diagnostics with special emphasis on radiological diagnostic criteria. A selective search of the literature in PubMed was carried out. Pituitary adenomas constitute 10-15 % of all intracranial tumors and are the most common tumors of the sellar region. Tumors smaller than 1 cm in diameter are called microadenomas while those larger than 1 cm in diameter are called macroadenomas. Approximately 65 % of pituitary gland adenomas secrete hormones whereby approximately 50 % secrete prolactin, 10 % secrete growth hormone (somatotropin) and 6 % secrete corticotropin. Other tumors located in the sella turcica can also cause endocrinological symptoms, such as an oversecretion of pituitary hormone or pituitary insufficiency by impinging on the pituitary gland or its stalk. When tumors spread into the space cranial to the sella turcica, they can impinge on the optic chiasm and cause visual disorders. A common differential diagnosis of a sellar tumor is a craniopharyngeoma. In children up to 10 % of all intracranial tumors are craniopharyngeomas. Other differential diagnoses for sellar tumors are metastases, meningiomas, epidermoids and in rare cases astrocytomas, germinomas or Rathke cleft cysts As these tumors are located in an anatomically complex region of the skull base and are often very small, a highly focused imaging protocol is required. The currently favored modality is magnetic resonance imaging (MRI) with the administration of a contrast agent. The sellar region should be mapped in thin slices. In cases of suspected microadenoma the imaging protocol should also contain a sequence with dynamic contrast administration in order to assess the specific enhancement characteristics of the tumor and the pituitary gland. (orig.) [German] Diese Arbeit ist eine Uebersicht ueber die haeufigsten Hypophysentumoren und deren Differenzialdiagnosen mit Augenmerk auf die

  19. Epilepsy and brain tumors

    Science.gov (United States)

    ENGLOT, DARIO J.; CHANG, EDWARD F.; VECHT, CHARLES J.

    2016-01-01

    Seizures are common in patients with brain tumors, and epilepsy can significantly impact patient quality of life. Therefore, a thorough understanding of rates and predictors of seizures, and the likelihood of seizure freedom after resection, is critical in the treatment of brain tumors. Among all tumor types, seizures are most common with glioneuronal tumors (70–80%), particularly in patients with frontotemporal or insular lesions. Seizures are also common in individuals with glioma, with the highest rates of epilepsy (60–75%) observed in patients with low-grade gliomas located in superficial cortical or insular regions. Approximately 20–50% of patients with meningioma and 20–35% of those with brain metastases also suffer from seizures. After tumor resection, approximately 60–90% are rendered seizure-free, with most favorable seizure outcomes seen in individuals with glioneuronal tumors. Gross total resection, earlier surgical therapy, and a lack of generalized seizures are common predictors of a favorable seizure outcome. With regard to anticonvulsant medication selection, evidence-based guidelines for the treatment of focal epilepsy should be followed, and individual patient factors should also be considered, including patient age, sex, organ dysfunction, comorbidity, or cotherapy. As concomitant chemotherapy commonly forms an essential part of glioma treatment, enzyme-inducing anticonvulsants should be avoided when possible. Seizure freedom is the ultimate goal in the treatment of brain tumor patients with epilepsy, given the adverse effects of seizures on quality of life. PMID:26948360

  20. Home-made temperature monitoring system from four-channel K-type thermocouples via internet of thing technology platform

    Science.gov (United States)

    Detmod, Thitaporn; Özmen, Yiǧiter; Songkaitiwong, Kittiphot; Saenyot, Khanuengchat; Locharoenrat, Kitsakorn; Lekchaum, Sarai

    2018-06-01

    This paper is aimed to design and construct the home-made temperature monitoring system from four-channel K-type thermocouples in order to improve the temperature measurement based on standard evaluation measurements guidance. The temperature monitoring system was capable to record the temperature on SD card and to display the realtime temperature on Internet of Thing Technology platform. The temperature monitoring system was tested in terms of the temperature measurement accuracy and delay response time. It was found that a standard deviation was acceptable as compared to the Instrument Society of America. The response time of the microcontroller to SD card was 2 sec faster than that of the microcontroller to Thingspeak.

  1. Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor

    International Nuclear Information System (INIS)

    Shirato, Hiroki; Shimizu, Shinichi; Kitamura, Kei; Nishioka, Takeshi; Kagei, Kenji; Hashimoto, Seiko; Aoyama, Hidefumi; Kunieda, Tatsuya; Shinohara, Nobuo; Dosaka-Akita, Hirotoshi; Miyasaka, Kazuo

    2000-01-01

    Purpose: To achieve precise three-dimensional (3D) conformal radiotherapy for mobile tumors, a new radiotherapy system and its treatment planning system were developed and used for clinical practice. Methods and Materials: We developed a linear accelerator synchronized with a fluoroscopic real-time tumor tracking system by which 3D coordinates of a 2.0-mm gold marker in the tumor can be determined every 0.03 second. The 3D relationships between the marker and the tumor at different respiratory phases are evaluated using CT image at each respiratory phase, whereby the optimum phase can be selected to synchronize with irradiation (4D treatment planning). The linac is triggered to irradiate the tumor only when the marker is located within the region of the planned coordinates relative to the isocenter. Results: The coordinates of the marker were detected with an accuracy of ± 1 mm during radiotherapy in the phantom experiment. The time delay between recognition of the marker position and the start or stop of megavoltage X-ray irradiation was 0.03 second. Fourteen patients with various tumors were treated by conformal radiotherapy with a 'tight' planning target volume (PTV) margin. They were surviving without relapse or complications with a median follow-up of 6 months. Conclusion: Fluoroscopic real-time tumor tracking radiotherapy following 4D treatment planning was developed and shown to be feasible to improve the accuracy of the radiotherapy for mobile tumors

  2. MR Histoanatomical Distribution of 290 Soft-tissue Tumors

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Tae Yong; Lee, In Sook; Lee, Gee Won; Kim, Jeung Il; Choi, Kyung Un; Kim, Won Taek [Pusan National University Hospital, Busan (Korea, Republic of)

    2008-12-15

    This study was designed too identify the MR histoanatomical distribution of soft-tissue tumors. A total of 290 soft-tissue tumors of 281 patients were analyzed by the use of MR imaging and were pathologically confirmed after surgical resection or a biopsy. There were 120 malignant soft-tissue tumors including tumors of an intermediate malignancy and 170 benign tumors. The histoanatomical locations were divided into three types: 'type I' with superficial layer tumors that involved the cutaneous and subcutaneous tissue, 'type II' with deep layer tumors that involved the muscle or tendon and 'type III' with soft tissue tumors that involved both the superficial and deep layers. Soft-tissue tumors with more than three cases with a frequency of more than 75% included dermatofibrosarcoma protuberans, glomus tumor, angiolipoma, leiomyosarcoma and lymphoma as 'type I' tumors. 'Type II' tumors with more than three cases with a frequency of more than 75% included liposarcoma, fibromatosis, papillary endothelial hyperplasia and rhabdomyosarcoma. 'Type III' tumors with more than three cases with a frequency of more than 50% included neurofibromatosis. The MR histoanatomical distributions of soft tissue tumors are useful in the differential pathological diagnosis when a soft-tissue tumor has a nonspecific MR appearance.

  3. Boiling point measurement of a small amount of brake fluid by thermocouple and its application.

    Science.gov (United States)

    Mogami, Kazunari

    2002-09-01

    This study describes a new method for measuring the boiling point of a small amount of brake fluid using a thermocouple and a pear shaped flask. The boiling point of brake fluid was directly measured with an accuracy that was within approximately 3 C of that determined by the Japanese Industrial Standards method, even though the sample volume was only a few milliliters. The method was applied to measure the boiling points of brake fluid samples from automobiles. It was clear that the boiling points of brake fluid from some automobiles dropped to approximately 140 C from about 230 C, and that one of the samples from the wheel cylinder was approximately 45 C lower than brake fluid from the reserve tank. It is essential to take samples from the wheel cylinder, as this is most easily subjected to heating.

  4. Analysis about correlation between the shape and histopathological locations of mammographic microcalcifications

    International Nuclear Information System (INIS)

    Kim, Wha Young; Cho, Young Ah; Choi, Hye Young; Sung, Soon Hee; Bacek, Seung Yeon

    1998-01-01

    To analyze the location of microcalcifications present on pathologic specimens and the relationship between the shape of clustered microcalcifications seen on mammogram and the location of these microcalcifications on pathologic specimen. In 84 female patients aged 25-68, we analysed the location of microcalcifications seen on pathologic speciments. In 65 cases, the shape of these microcalcifications correlated with their location. These shapes, as seen on mammograms, were classified as granular, linear, or branching;the location of microcalcifications was difined as intraductal, stromal, lobular, or a mixture of the three. To determine the difference, if any, between pathologic diagnosis and pathological location and shape as seen on mammograms, statistical analysis using the Chi-square test was performed. Among 84 cases, 51 were benign and 33cases were malignant. In both types of disease, in 45% and 58% of cases, respectively, microcalcifications were located intraductally. There was no statistically significant difference between pathologic diagnosis and pathologic locations (p=3D0.191);analysis of the relationship between shape of microcalcification and pathological location similarly revealed no statistically significant difference(p>0.05). In four of 33 cases of malignant disease(12%), there was microcalcification not only of the tumor itself but also of the adjacent non-tumorous region. Regardless of whether the disease was benign or melignant, microcalcifieations were most commonly intraductal. The relationship between shape and location of microcalcifications seen on pathologic specimens demonstrated no statistical significance.=20

  5. Scanning thermal microscopy based on a quartz tuning fork and a micro-thermocouple in active mode (2ω method)

    International Nuclear Information System (INIS)

    Bontempi, Alexia; Nguyen, Tran Phong; Salut, Roland; Thiery, Laurent; Teyssieux, Damien; Vairac, Pascal

    2016-01-01

    A novel probe for scanning thermal microscope using a micro-thermocouple probe placed on a Quartz Tuning Fork (QTF) is presented. Instead of using an external deflection with a cantilever beam for contact detection, an original combination of piezoelectric resonator and thermal probe is employed. Due to a non-contact photothermal excitation principle, the high quality factor of the QTF allows the probe-to-surface contact detection. Topographic and thermal scanning images obtained on a specific sample points out the interest of our system as an alternative to cantilevered resistive probe systems which are the most spread.

  6. Scanning thermal microscopy based on a quartz tuning fork and a micro-thermocouple in active mode (2ω method).

    Science.gov (United States)

    Bontempi, Alexia; Nguyen, Tran Phong; Salut, Roland; Thiery, Laurent; Teyssieux, Damien; Vairac, Pascal

    2016-06-01

    A novel probe for scanning thermal microscope using a micro-thermocouple probe placed on a Quartz Tuning Fork (QTF) is presented. Instead of using an external deflection with a cantilever beam for contact detection, an original combination of piezoelectric resonator and thermal probe is employed. Due to a non-contact photothermal excitation principle, the high quality factor of the QTF allows the probe-to-surface contact detection. Topographic and thermal scanning images obtained on a specific sample points out the interest of our system as an alternative to cantilevered resistive probe systems which are the most spread.

  7. Scanning thermal microscopy based on a quartz tuning fork and a micro-thermocouple in active mode (2ω method)

    Energy Technology Data Exchange (ETDEWEB)

    Bontempi, Alexia; Nguyen, Tran Phong; Salut, Roland; Thiery, Laurent; Teyssieux, Damien; Vairac, Pascal [FEMTO-ST Institute UMR 6174, Université de Franche-Comté, CNRS, ENSMM, UTBM, 15B Avenue des Montboucons, F-25030 Besançon (France)

    2016-06-15

    A novel probe for scanning thermal microscope using a micro-thermocouple probe placed on a Quartz Tuning Fork (QTF) is presented. Instead of using an external deflection with a cantilever beam for contact detection, an original combination of piezoelectric resonator and thermal probe is employed. Due to a non-contact photothermal excitation principle, the high quality factor of the QTF allows the probe-to-surface contact detection. Topographic and thermal scanning images obtained on a specific sample points out the interest of our system as an alternative to cantilevered resistive probe systems which are the most spread.

  8. Brain's tumor image processing using shearlet transform

    Science.gov (United States)

    Cadena, Luis; Espinosa, Nikolai; Cadena, Franklin; Korneeva, Anna; Kruglyakov, Alexey; Legalov, Alexander; Romanenko, Alexey; Zotin, Alexander

    2017-09-01

    Brain tumor detection is well known research area for medical and computer scientists. In last decades there has been much research done on tumor detection, segmentation, and classification. Medical imaging plays a central role in the diagnosis of brain tumors and nowadays uses methods non-invasive, high-resolution techniques, especially magnetic resonance imaging and computed tomography scans. Edge detection is a fundamental tool in image processing, particularly in the areas of feature detection and feature extraction, which aim at identifying points in a digital image at which the image has discontinuities. Shearlets is the most successful frameworks for the efficient representation of multidimensional data, capturing edges and other anisotropic features which frequently dominate multidimensional phenomena. The paper proposes an improved brain tumor detection method by automatically detecting tumor location in MR images, its features are extracted by new shearlet transform.

  9. Management of rectal inflammatory myofibroblastic tumor recurrence

    Directory of Open Access Journals (Sweden)

    Lan Sun

    2014-01-01

    Full Text Available Inflammatory myofibroblastic tumor (IMT is an uncommon mesenchymal neoplasm of intermediate malignant potential. It may occur in various anatomic locations, but rarely in the rectum. This is a case discussion of a 36-year-old male patient with IMT of the rectum. After the patient underwent radical surgery, recurrence was seen after 18 months. Because the tumor was very close to the surrounding tissue, palliative tumor resection was performed followed by concurrent chemo-radiation and non-steroidal anti-inflammatory drugs (NSAID. After 2-year follow-up, the patient has no evidence of recurrence or metastasis. Surgical resection is very important for patient with rectal IMT, even in relapse cases. And adjuvant chemoradiotherapy and NSAID are in favor of the incompletely resected tumors as our case. But perhaps, the adjuvant treatments could be helpful after radical resection of rectal tumor.

  10. Primary tumor location as a predictor of the benefit of palliative resection for colorectal cancer with unresectable metastasis.

    Science.gov (United States)

    Zhang, Rong-Xin; Ma, Wen-Juan; Gu, Yu-Ting; Zhang, Tian-Qi; Huang, Zhi-Mei; Lu, Zhen-Hai; Gu, Yang-Kui

    2017-07-27

    It is still under debate that whether stage IV colorectal cancer patients with unresectable metastasis can benefit from primary tumor resection, especially for asymptomatic colorectal cancer patients. Retrospective studies have shown controversial results concerning the benefit from surgery. This retrospective study aims to evaluate whether the site of primary tumor is a predictor of palliative resection in asymptomatic stage IV colorectal cancer patients. One hundred ninety-four patients with unresectable metastatic colorectal cancer were selected from Sun Yat-sen University Cancer Center Database in the period between January 2007 and December 2013. All information was carefully reviewed and collected, including the treatment, age, sex, carcinoembryonic antigen, site of tumor, histology, cancer antigen 199, number of liver metastases, and largest diameter of liver metastasis. The univariate and multivariate analyses were used to detect the relationship between primary tumor resection and overall survival of unresectable stage IV colorectal cancer patients. One hundred twenty-five received palliative resection, and 69 received only chemotherapy. Multivariate analysis indicated that primary tumor site was one of the independent factors (RR 0.569, P = 0.007) that influenced overall survival. For left-side colon cancer patients, primary tumor resection prolonged the median overall survival time for 8 months (palliative resection vs. no palliative resection: 22 vs. 14 months, P = 0.009); however, for right-side colon cancer patients, palliative resection showed no benefit (12 vs. 10 months, P = 0.910). This study showed that left-side colon cancer patients might benefit from the primary tumor resection in terms of overall survival. This result should be further explored in a prospective study.

  11. Frontal bone hemangioma in an 8-year-old female: A common tumor in a rare location

    Directory of Open Access Journals (Sweden)

    Abhimanyu Sharma

    2016-01-01

    Full Text Available Intraosseous hemangioma is a rare bone tumor accounting for 0.7%–1.0% of all bone tumors. In the skull, frontal bone is the commonly involved bone. An 8-year-old female presented to our outpatient department with complaints of pain and swelling over forehead for 4 months. X-ray revealed a lytic expansile lesion involving frontal bone with sunburst pattern of bony spicules radiating to periphery of the lesion. Magnetic resonance imaging revealed the presence of a well-circumscribed lesion with both intra as well as extracranial components. Histopathology revealed a vascular tumor consisting of both small (capillary and large (cavernous sized vessels. A diagnosis of mixed type of hemangioma of the frontal bone was given. Recognition of hemangioma on radiology and confirmation by histopathology is essential for proper management as it might be confused clinically with other locally aggressive/malignant lesions.

  12. Osteosarcoma of the spheno-temporo-orbital bone: Imaging aspects of such unusual location

    Directory of Open Access Journals (Sweden)

    ABDEL ILAH RAYAN ALAOUI BOUARRAQUI

    2018-05-01

    Full Text Available Osteosarcoma of the spheno-temporo-orbital bone is a very rare tumor. Despite the fact that primary osteogenic sarcomas are the most common bone neoplasm, their location in the skull bone is uncommon representing less than 2% of all skull tumors. We report the case of a 41-year-old woman, who has experienced periorbital pain with exophthalmos and left eye vision loss. Neuroimaging analysis including both brain computed tomography (CT-scan and Magnetic resonance imaging (MRI were performed. Although radiographic features of skull bone osteosarcomas are not specific, the combination of several radiographic features could lead to this diagnosis in such rare location. The final diagnosis was established by a trans-temporal biopsy with immunohistochemical study. Neurosurgical resection of the primary tumor was not possible given the important extent of the tumor and the involvement of adjacent structures, so the patient underwent conformational radiotherapy. The evolution was marked by local and metastatic progression. The patient received palliative chemotherapy and died few months later. The purpose of presenting this case is not only to report an uncommon malignancy of the skull bone, but also to provide imaging aspects of this rare location and to raise awareness among radiologists in order to consider this radiological entity as a differential diagnosis when a skull bone process is identified.

  13. Differentiation between Superficial and Deep Lobe Parotid Tumors by Magnetic Resonance Imaging: Usefulness of the Parotid Duct Criterion

    Energy Technology Data Exchange (ETDEWEB)

    Imaizumi, A.; Kuribayashi, A.; Okochi, K.; Yoshino, N.; Kurabayashi, T. (Oral and Maxillofacial Radiology, Graduate School, Tokyo Medical and Dental Univ., Tokyo (Japan)); Ishii, J. (Maxillofacial Surgery, Graduate School, Tokyo Medical and Dental Univ., Tokyo (Japan)); Sumi, Y. (Division of Oral and Dental Surgery, Dept. of Advanced Medicine, National Center for Geriatrics and Gerontology, Aichi (Japan))

    2009-08-15

    Background: The location of a parotid tumor affects the choice of surgery, and there is a risk of damaging the facial nerve during surgery. Thus, differentiation between superficial and deep lobe parotid tumors is important for appropriate surgical planning. Purpose: To evaluate the usefulness of using the parotid duct, in addition to the retromandibular vein, for differentiating between superficial and deep lobe parotid tumors on MR images. Material and Methods: Magnetic resonance images of 42 parotid tumors in 40 patients were reviewed to determine whether the tumor was located in the superficial or deep lobe. In each case, the retromandibular vein and the parotid duct were used to locate the tumor. The parotid duct was only used in cases where the tumor and the duct were visualized on the same image. Results: Using the retromandibular vein criterion, 71% of deep lobe and 86% of superficial lobe tumors were correctly diagnosed, providing an accuracy of 81%. However, the accuracy achieved when using the parotid duct criterion was 100%, although it could be applied to only 28 of the 42 cases. Based on these results, we defined the following diagnostic method: the parotid duct criterion is first applied, and for cases in which it cannot be applied, the retromandibular vein criterion is used. The accuracy of this method was 88%, which was better than that achieved using the retromandibular vein criterion alone. Conclusion: The parotid duct criterion is useful for determining the location of parotid tumors. Combining the parotid duct criterion with the retromandibular vein criterion might improve the diagnostic accuracy of parotid tumor location compared to using the latter criterion alone

  14. Differentiation between Superficial and Deep Lobe Parotid Tumors by Magnetic Resonance Imaging: Usefulness of the Parotid Duct Criterion

    International Nuclear Information System (INIS)

    Imaizumi, A.; Kuribayashi, A.; Okochi, K.; Yoshino, N.; Kurabayashi, T.; Ishii, J.; Sumi, Y.

    2009-01-01

    Background: The location of a parotid tumor affects the choice of surgery, and there is a risk of damaging the facial nerve during surgery. Thus, differentiation between superficial and deep lobe parotid tumors is important for appropriate surgical planning. Purpose: To evaluate the usefulness of using the parotid duct, in addition to the retromandibular vein, for differentiating between superficial and deep lobe parotid tumors on MR images. Material and Methods: Magnetic resonance images of 42 parotid tumors in 40 patients were reviewed to determine whether the tumor was located in the superficial or deep lobe. In each case, the retromandibular vein and the parotid duct were used to locate the tumor. The parotid duct was only used in cases where the tumor and the duct were visualized on the same image. Results: Using the retromandibular vein criterion, 71% of deep lobe and 86% of superficial lobe tumors were correctly diagnosed, providing an accuracy of 81%. However, the accuracy achieved when using the parotid duct criterion was 100%, although it could be applied to only 28 of the 42 cases. Based on these results, we defined the following diagnostic method: the parotid duct criterion is first applied, and for cases in which it cannot be applied, the retromandibular vein criterion is used. The accuracy of this method was 88%, which was better than that achieved using the retromandibular vein criterion alone. Conclusion: The parotid duct criterion is useful for determining the location of parotid tumors. Combining the parotid duct criterion with the retromandibular vein criterion might improve the diagnostic accuracy of parotid tumor location compared to using the latter criterion alone

  15. EBR-II in-vessel natural circulation experiments on hot and cold pool stratification

    International Nuclear Information System (INIS)

    Ragland, W.A.; Feldman, E.E.

    1990-01-01

    The Experimental Breeder Reactor II is located in a cylindrical pool of liquid sodium which is part of the cold-leg of the primary flow circuit. A vertical string of 32 thermocouples spans the 8 m tank height, at each of two diametrically opposed locations in the primary tank. Local temperatures were measured with these 64 thermocouples during dynamic tests. The instantaneous spacial temperature distribution obtained from a string of thermocouples can be viewed on a personal computer. The animation which results from displaying successive spacial distributions provide a very effective way to quickly obtain physical insights. The design of the two strings of thermocouples, the software used to create the animation, measured data from three different types of tests--two unprotected reactor transients, and one with the reactor at decay power levels and the reactor cover lifted, are discussed. 5 refs., 3 figs

  16. Tumor of granular cells of esophagus

    International Nuclear Information System (INIS)

    Gonzalez Fabian, Licet; Diaz Anaya, Amnia; Perez de la Torre, Georgina

    2010-01-01

    Granular cells tumors are rare and asymptomatic lesions and by general, it is an incidental finding en high or low endoscopy. They were described for the first time by Abrikossoff in 1926. The more frequent locations are the buccal mucosa, dermis and subcutaneous cellular tissue, most of these tumors has a benign origin. This is the case of a woman aged 44 with a pyrosis history from a year ago; by high endoscopy it is noted a 8 mm lesion distal to esophagus and confirmed by histological study of granular cells tumor. Elective treatment of this lesion is the endoscopic polypectomy. Despite that the malign potential is low; we suggested a close clinical and endoscopic follow-up.

  17. Fibrogenesis and carcinoid tumor - a case report

    Directory of Open Access Journals (Sweden)

    Eduardo Fonseca Alves Filho

    2012-06-01

    Full Text Available Carcinoid tumors are rare. They may appear in the entire gastrointestinal and respiratory tracts, with single or multiple occurrences. Prognosis is dependent on the size and location. Symptoms may appear in carcinoid syndrome, related to active substances, especially serotonin. One important aspect associated with these tumors and usually ignored is fibrogenesis. This is a case report of a patient with carcinoid tumor of the terminal ileum, treated by laparoscopy, associated with fat and fibrosis infiltration.Tumores carcinoides são pouco frequentes, podem surgir em todo o trato gastrointestinal e respiratório, podem ser únicos ou múltiplos. O prognóstico depende do tamanho e da localização do tumor. Podem ocorrer sintomas relacionados à síndrome carcinoide, decorrente da produção de substâncias ativas, em especial serotonina. Um aspecto comumente ignorado associado a estes tumores é a estimulação da fibrogênese. Relatamos um caso de tumor carcinoide de íleo, tratado por videolaparoscopia, associado à infiltração fibroadiposa.

  18. n+ GaAs/AuGeNi-Au Thermocouple-Type RF MEMS Power Sensors Based on Dual Thermal Flow Paths in GaAs MMIC

    Directory of Open Access Journals (Sweden)

    Zhiqiang Zhang

    2017-06-01

    Full Text Available To achieve radio frequency (RF power detection, gain control, and circuit protection, this paper presents n+ GaAs/AuGeNi-Au thermocouple-type RF microelectromechanical system (MEMS power sensors based on dual thermal flow paths. The sensors utilize a conversion principle of RF power-heat-voltage, where a thermovoltage is obtained as the RF power changes. To improve the heat transfer efficiency and the sensitivity, structures of two heat conduction paths are designed: one in which a thermal slug of Au is placed between two load resistors and hot junctions of the thermocouples, and one in which a back cavity is fabricated by the MEMS technology to form a substrate membrane underneath the resistors and the hot junctions. The improved sensors were fabricated by a GaAs monolithic microwave integrated circuit (MMIC process. Experiments show that these sensors have reflection losses of less than −17 dB up to 12 GHz. At 1, 5, and 10 GHz, measured sensitivities are about 63.45, 53.97, and 44.14 µV/mW for the sensor with the thermal slug, and about 111.03, 94.79, and 79.04 µV/mW for the sensor with the thermal slug and the back cavity, respectively.

  19. Transarticular invasion of the sacroiliac joints by malignant pelvic bone tumors

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hwang Woo; Huh, Jin Do; Kim, Seong Min; Cho, Young Duk [College of Medicine, Kosin Univ., Pusan (Korea, Republic of); Cho, Kil Ho [College of Medicine, Yeungnam Univ., Daegu (Korea, Republic of)

    2002-03-01

    To describe modes of transarticular invasion, with reference to the size and location of a tumor, the anatomic characteristics of invaded cartilage,and the existence of ankylosis in SI joint. Eleven histologically confirmed malignant pelvic bone tumors involving transarticular invasion of sacroiliac joints, were retrospectively analysed. Transarticular invasion of a joint was defined as involvement of its opposing bones. The anatomic site and size of the tumors were analysed, and invaded sacroiliac joint was divided into upper, middle and lower parts on the basis of the anatomic characteristics of the intervening cartilage: synovial hyaline or fibrous ligamentous. the existence of ankylosis was determined, and transarticular invasion directly across a joint was classified as direct invasion. Extension of tumors around a joint from its periphery to the opposing bone were considered as indirect invasion. All tumors were located near the sacroiliac joint, eight at the ilium and three at the sacrum. Six invasions were indirect and five were direct. Average tumor area was larger in indirect cases than in direct: 191.8 cm{sup 2} vs. 69.6 cm{sup 2}. In all indirect invasions, a huge soft tissue mass abutted onto the peripheral portion of the sacroiliac joint. In five of six cases of indirect transarticular invasion, the upper part of the joint posteriorly located fibrous ligamentous cartilage. In the other, the lower part was invaded, and this involved a detour around the joint space, avoiding the invasion of intervening cartilage. Ankylosis occurred in one of the indirect cases. Among the five cases of direct invasion, there was invasion of the posteriorly located ligamentous fibrous cartilage in three without ankylosis. In the other two cases, involving ankylosis, the synovial hyaline cartilage was invaded directly at the lower part of the joint. Transarticular invasions of sacroiliac joint via fibrous cartilage are most common. Ankylosis of the sacroiliac joint

  20. Transarticular invasion of the sacroiliac joints by malignant pelvic bone tumors

    International Nuclear Information System (INIS)

    Lee, Hwang Woo; Huh, Jin Do; Kim, Seong Min; Cho, Young Duk; Cho, Kil Ho

    2002-01-01

    To describe modes of transarticular invasion, with reference to the size and location of a tumor, the anatomic characteristics of invaded cartilage,and the existence of ankylosis in SI joint. Eleven histologically confirmed malignant pelvic bone tumors involving transarticular invasion of sacroiliac joints, were retrospectively analysed. Transarticular invasion of a joint was defined as involvement of its opposing bones. The anatomic site and size of the tumors were analysed, and invaded sacroiliac joint was divided into upper, middle and lower parts on the basis of the anatomic characteristics of the intervening cartilage: synovial hyaline or fibrous ligamentous. the existence of ankylosis was determined, and transarticular invasion directly across a joint was classified as direct invasion. Extension of tumors around a joint from its periphery to the opposing bone were considered as indirect invasion. All tumors were located near the sacroiliac joint, eight at the ilium and three at the sacrum. Six invasions were indirect and five were direct. Average tumor area was larger in indirect cases than in direct: 191.8 cm 2 vs. 69.6 cm 2 . In all indirect invasions, a huge soft tissue mass abutted onto the peripheral portion of the sacroiliac joint. In five of six cases of indirect transarticular invasion, the upper part of the joint posteriorly located fibrous ligamentous cartilage. In the other, the lower part was invaded, and this involved a detour around the joint space, avoiding the invasion of intervening cartilage. Ankylosis occurred in one of the indirect cases. Among the five cases of direct invasion, there was invasion of the posteriorly located ligamentous fibrous cartilage in three without ankylosis. In the other two cases, involving ankylosis, the synovial hyaline cartilage was invaded directly at the lower part of the joint. Transarticular invasions of sacroiliac joint via fibrous cartilage are most common. Ankylosis of the sacroiliac joint facilitates

  1. Intra-adrenal murine TH-MYCN neuroblastoma tumors grow more aggressive and exhibit a distinct tumor microenvironment relative to their subcutaneous equivalents.

    Science.gov (United States)

    Kroesen, Michiel; Brok, Ingrid C; Reijnen, Daphne; van Hout-Kuijer, Maaike A; Zeelenberg, Ingrid S; Den Brok, Martijn H; Hoogerbrugge, Peter M; Adema, Gosse J

    2015-05-01

    In around half of the patients with neuroblastoma (NBL), the primary tumor is located in one of the adrenal glands. We have previously reported on a transplantable TH-MYCN model of subcutaneous (SC) growing NBL in C57Bl/6 mice for immunological studies. In this report, we describe an orthotopic TH-MYCN transplantable model where the tumor cells were injected intra-adrenally (IA) by microsurgery. Strikingly, 9464D cells grew out much faster in IA tumors compared to the subcutis. Tumors were infiltrated by equal numbers of lymphocytes and myeloid cells. Within the myeloid cell population, however, tumor-infiltrating macrophages were more abundant in IA tumors compared to SC tumors and expressed lower levels of MHC class II, indicative of a more immunosuppressive phenotype. Using 9464D cells stably expressing firefly luciferase, enhanced IA tumor growth could be confirmed using bioluminescence. Collectively, these data show that the orthotopic IA localization of TH-MYCN cells impacts the NBL tumor microenvironment, resulting in a more stringent NBL model to study novel immunotherapeutic approaches for NBL.

  2. Viking Afterbody Heating Computations and Comparisons to Flight Data

    Science.gov (United States)

    Edquist, Karl T.; Wright, Michael J.; Allen, Gary A., Jr.

    2006-01-01

    Computational fluid dynamics predictions of Viking Lander 1 entry vehicle afterbody heating are compared to flight data. The analysis includes a derivation of heat flux from temperature data at two base cover locations, as well as a discussion of available reconstructed entry trajectories. Based on the raw temperature-time history data, convective heat flux is derived to be 0.63-1.10 W/cm2 for the aluminum base cover at the time of thermocouple failure. Peak heat flux at the fiberglass base cover thermocouple is estimated to be 0.54-0.76 W/cm2, occurring 16 seconds after peak stagnation point heat flux. Navier-Stokes computational solutions are obtained with two separate codes using an 8- species Mars gas model in chemical and thermal non-equilibrium. Flowfield solutions using local time-stepping did not result in converged heating at either thermocouple location. A global time-stepping approach improved the computational stability, but steady state heat flux was not reached for either base cover location. Both thermocouple locations lie within a separated flow region of the base cover that is likely unsteady. Heat flux computations averaged over the solution history are generally below the flight data and do not vary smoothly over time for both base cover locations. Possible reasons for the mismatch between flight data and flowfield solutions include underestimated conduction effects and limitations of the computational methods.

  3. Anatomy, gross tumor volume and clinical target volume: tumors of the lower third of the esophagus and the gastro esophageal junction

    International Nuclear Information System (INIS)

    Calais, G.; Asquier, E.; Louisot, P.

    2001-01-01

    The esophagus is divided into four regions: cervical esophagus, intrathoracic esophagus with upper, mid and lower thoracic portion. Cancer may occur on each of these regions. Computed tomography of the thorax and superior abdomen and endoscopic ultrasound are necessary for reliable staging. CT simulation allows accurate definition of tumor volume. GTV includes tumor volume and regional lymph nodes. CTV encompasses GTV plus safety margin and lymph nodes areas considered to harbor potential microscopic disease. The extent of prophylactic lymph node irradiation depends on the anatomic location of the primary tumor. (author)

  4. Warthin's Tumor of the Parotid Gland: CT and MR Features

    International Nuclear Information System (INIS)

    Lee, Yun Hee; Yu, In Kyu; Lee, Byung Hee; Kim, Min Sun; Han, Moon Hee; Song, Chang Joon

    2009-01-01

    In this study, we have evaluated the imaging features of Warthin's tumor of the parotid gland with the use of CT and MR imaging. CT (n = 30) and MR (n = 7) images of 26 patients (M:F=23:3; age range, 38-76 years; mean age, 58 years) with surgically-proven Warthin's tumor (n = 37) were reviewed with a focus on bilaterality, multiplicity, location, size, demarcation, margin, enhancement pattern and MR signal intensity. Lesions were bilateral in seven patients (27%), multiple in nine patients (35%) and unilateral multiple in four patients (15%). Tumors were located in the superficial lobe (65%), deep lobe (24%) and both lobes (11%) of the parotid gland. Most tumors had a clear (95%) and smooth margin (95%) with a round or oval shape. Tumors mainly showed a solid and cystic composition (n = 24, 65%) and all solid stroma showed poor or weak enhancement on both CT and MR images. Papillary projections from the peripheral wall were clearly seen (n = 6, 86%). Warthin's tumor is frequently seen in the parotid superficial lobe of older males with a higher bilateral and multiple tendency. Warthin's tumor shows cystic portions with papillary projections at the wall on CT images and focal high signal intensity (SI) on T1-weighted images with dense nodular enhancement on MR images

  5. Early-postoperative magnetic resonance imaging in glial tumors: prediction of tumor regrowth and recurrence

    Energy Technology Data Exchange (ETDEWEB)

    Ekinci, Gazanfer; Akpinar, Ihsan N. E-mail: i.akpinar@mailcity.com; Baltacioglu, Feyyaz; Erzen, Canan; Kilic, Tuerker; Elmaci, Ilhan; Pamir, Necmettin

    2003-02-01

    Objective: This study investigated the value of early-postoperative magnetic resonance (EPMR) imaging in the detection of residual glial tumor and investigated the role of EPMR for the prediction of tumor regrowth and recurrence. Methods and materials: We retrospectively analyzed pre- and post-operative magnetic resonance imaging results from 50 adult patients who underwent surgical treatment for supratentorial glial tumor. There were glioblastoma multiforme in 25 patients, astrocytoma (grades II and III) in 11 patients, oligodendroglioma (grades II and III) in 9 patients, and oligoastrocytoma (grades II and III) in 5 patients. EPMR imaging was performed within 24 h after surgery. EPMR findings were compared with the neurosurgeon's intraoperative estimation of gross tumor removal. Patterns of contrast enhancement at the resection site, in residual and developing tumor tissue and blood at the resection site were evaluated on EPMR and in follow-up studies. 'Residual tumor' was defined as contrast enhancing mass at the operative site on EPMR. 'Regrowth' was defined as contrast enhancing mass detected on follow-up in the same location as the primary tumor. 'Recurrence' was defined as appearance of a mass lesion in the brain parenchyma distant from the resection bed during follow-up. Results: Nineteen patients showed no evidence of residual tumor, regrowth, or recurrence on EPMR or any of the later follow-up radiological examinations. EPMR identified 20 cases of residual tumor. Follow-up showed tumor regrowth in 10 patients, and tumor recurrence in 1 case. EPMR showed contrast enhancement of the resection bed in 45 of the 50 patients. Four of the 20 residual tumors showed a thick linear enhancement pattern, and the other 16 cases exhibited thick linear-nodular enhancement. No thin linear enhancement was observed in the residual tumor group. Nine of the 10-regrowth tumors showed a thick linear-nodular enhancement pattern, and one

  6. The Role of Fine Needle Aspiration in the Diagnosis of Parotid Gland Tumors: Correlation With Preoperative Computerized Tomography Tumor Size.

    Science.gov (United States)

    Ghantous, Yasmine; Naddaf, Raja; Barak, Michal; Abd-Elraziq, Murad; Abu Eln-Naaj, Imad

    2016-03-01

    The role of fine needle aspiration cytology (FNAC) in the diagnosis of parotid gland masses is still controversial, regarding its sensitivity and specificity that vary between 41% and 100% and between 86% and 100% respectively.The aim of this study was to identify the specificity and sensitivity of FNAC of parotid gland tumors in relation to the tumor size as characterized preoperatively by computer tomography. The medical files of 79 patients whom were referred to the MaxilloFacila Surgery Department, Rambam medical center, over a 10.5-year period (2000-2010) were analyzed retrospectively.The extensity of the operation was determined by the location of the tumor as presented in computed tomography (CT) radiography, and preoperative FNAC examination.The majority of the masses were located in the superficial lobe (88.52%), and only 11.48% of the patients were located in the deep lobe (8:1 ratio). FNAC results were nondiagnostic in 7 patients (8.86%), 62 patients were diagnosed as inflammatory and benign lesion in (78.48%), malignant tumors were diagnosed in 10 patients (12.65%).The sensitivity in our study was 90%, the specificity was 98%, positive predictive value was 90%, negative predictive value was 98%, and diagnostic accuracy was 88%. The positive predictive value was 90%, the negative predictive value was 98%.Analyzing the effect of the preoperative CT size upon the accuracy of the FNAC diagnosis, we found that lesion with preoperative CT size greater than 24 mm has a more accurate FNAC result (P = 0.034).

  7. Combination radiotherapy in an orthotopic mouse brain tumor model.

    Science.gov (United States)

    Kramp, Tamalee R; Camphausen, Kevin

    2012-03-06

    Glioblastoma multiforme (GBM) are the most common and aggressive adult primary brain tumors. In recent years there has been substantial progress in the understanding of the mechanics of tumor invasion, and direct intracerebral inoculation of tumor provides the opportunity of observing the invasive process in a physiologically appropriate environment. As far as human brain tumors are concerned, the orthotopic models currently available are established either by stereotaxic injection of cell suspensions or implantation of a solid piece of tumor through a complicated craniotomy procedure. In our technique we harvest cells from tissue culture to create a cell suspension used to implant directly into the brain. The duration of the surgery is approximately 30 minutes, and as the mouse needs to be in a constant surgical plane, an injectable anesthetic is used. The mouse is placed in a stereotaxic jig made by Stoetling (figure 1). After the surgical area is cleaned and prepared, an incision is made; and the bregma is located to determine the location of the craniotomy. The location of the craniotomy is 2 mm to the right and 1 mm rostral to the bregma. The depth is 3 mm from the surface of the skull, and cells are injected at a rate of 2 μl every 2 minutes. The skin is sutured with 5-0 PDS, and the mouse is allowed to wake up on a heating pad. From our experience, depending on the cell line, treatment can take place from 7-10 days after surgery. Drug delivery is dependent on the drug composition. For radiation treatment the mice are anesthetized, and put into a custom made jig. Lead covers the mouse's body and exposes only the brain of the mouse. The study of tumorigenesis and the evaluation of new therapies for GBM require accurate and reproducible brain tumor animal models. Thus we use this orthotopic brain model to study the interaction of the microenvironment of the brain and the tumor, to test the effectiveness of different therapeutic agents with and without

  8. Tumor-induced osteomalacia

    Directory of Open Access Journals (Sweden)

    Pablo Florenzano

    2017-12-01

    Full Text Available Tumor-induced osteomalacia (TIO is a rare paraneoplastic syndrome clinically characterized by bone pain, fractures and muscle weakness. It is caused by tumoral overproduction of fibroblast growth factor 23 (FGF23 that acts primarily at the proximal renal tubule, decreasing phosphate reabsorption and 1α-hydroxylation of 25 hydroxyvitamin D, thus producing hypophosphatemia and osteomalacia. Lesions are typically small, benign mesenchymal tumors that may be found in bone or soft tissue, anywhere in the body. In up to 60% of these tumors, a fibronectin-1(FN1 and fibroblast growth factor receptor-1 (FGFR1 fusion gene has been identified that may serve as a tumoral driver. The diagnosis is established by the finding of acquired chronic hypophosphatemia due to isolated renal phosphate wasting with concomitant elevated or inappropriately normal blood levels of FGF23 and decreased or inappropriately normal 1,25-OH2-Vitamin D (1,25(OH2D. Locating the tumor is critical, as complete removal is curative. For this purpose, a step-wise approach is recommended, starting with a thorough medical history and physical examination, followed by functional imaging. Suspicious lesions should be confirmed by anatomical imaging, and if needed, selective venous sampling with measurement of FGF23. If the tumor is not localized, or surgical resection is not possible, medical therapy with phosphate and active vitamin D is usually successful in healing the osteomalacia and reducing symptoms. However, compliance is often poor due to the frequent dosing regimen and side effects. Furthermore, careful monitoring is needed to avoid complications such us secondary/tertiary hyperparathyroidism, hypercalciuria, and nephrocalcinosis. Novel therapeutical approaches are being developed for TIO patients, such as image-guided tumor ablation and medical treatment with the anti-FGF23 monoclonal antibody KRN23 or anti FGFR medications. The case of a patient with TIO is presented to

  9. Fiber tracking for brain tumor

    International Nuclear Information System (INIS)

    Yamada, Kei; Nakamura, Hisao; Ito, Hirotoshi; Tanaka, Osamu; Kubota, Takao; Yuen, Sachiko; Kizu, Osamu; Nishimura, Tsunehiko

    2003-01-01

    The purpose of this study was to validate an innovative scanning method for patients diagnosed with brain tumors. Using a 1.5 Tesla whole body magnetic resonance (MR) imager, 23 patients with brain tumors were scanned. The recorded data points of the diffusion-tensor imaging (DTI) sequences were 128 x 37 with the parallel imaging technique. The parallel imaging technique was equivalent to a true resolution of 128 x 74. The scan parameters were repetition time (TR)=6000, echo time (TE)=88, 6 averaging with a b-value of 800 s/mm 2 . The total scan time for DTI was 4 minutes and 24 seconds. DTI scans and subsequent fiber tracking were successfully applied in all cases. All fiber tracts on the contralesional side were visualized in the expected locations. Fiber tracts on the lesional side had varying degrees of displacement, disruption, or a combination of displacement and disruption due to the tumor. Tract disruption resulted from direct tumor involvement, compression upon the tract, and vasogenic edema surrounding the tumor. This DTI method using a parallel imaging technique allows for clinically feasible fiber tracking that can be incorporated into a routine MR examination. (author)

  10. Awake craniotomy for tumor resection.

    Science.gov (United States)

    Attari, Mohammadali; Salimi, Sohrab

    2013-01-01

    Surgical treatment of brain tumors, especially those located in the eloquent areas such as anterior temporal, frontal lobes, language, memory areas, and near the motor cortex causes high risk of eloquent impairment. Awake craniotomy displays major rule for maximum resection of the tumor with minimum functional impairment of the Central Nervous System. These case reports discuss the use of awake craniotomy during the brain surgery in Alzahra Hospital, Isfahan, Iran. A 56-year-old woman with left-sided body hypoesthesia since last 3 months and a 25-year-old with severe headache of 1 month duration were operated under craniotomy for brain tumors resection. An awake craniotomy was planned to allow maximum tumor intraoperative testing for resection and neurologic morbidity avoidance. The method of anesthesia should offer sufficient analgesia, hemodynamic stability, sedation, respiratory function, and also awake and cooperative patient for different neurological test. Airway management is the most important part of anesthesia during awake craniotomy. Tumor surgery with awake craniotomy is a safe technique that allows maximal resection of lesions in close relationship to eloquent cortex and has a low risk of neurological deficit.

  11. Awake craniotomy for tumor resection

    Directory of Open Access Journals (Sweden)

    Mohammadali Attari

    2013-01-01

    Full Text Available Surgical treatment of brain tumors, especially those located in the eloquent areas such as anterior temporal, frontal lobes, language, memory areas, and near the motor cortex causes high risk of eloquent impairment. Awake craniotomy displays major rule for maximum resection of the tumor with minimum functional impairment of the Central Nervous System. These case reports discuss the use of awake craniotomy during the brain surgery in Alzahra Hospital, Isfahan, Iran. A 56-year-old woman with left-sided body hypoesthesia since last 3 months and a 25-year-old with severe headache of 1 month duration were operated under craniotomy for brain tumors resection. An awake craniotomy was planned to allow maximum tumor intraoperative testing for resection and neurologic morbidity avoidance. The method of anesthesia should offer sufficient analgesia, hemodynamic stability, sedation, respiratory function, and also awake and cooperative patient for different neurological test. Airway management is the most important part of anesthesia during awake craniotomy. Tumor surgery with awake craniotomy is a safe technique that allows maximal resection of lesions in close relationship to eloquent cortex and has a low risk of neurological deficit.

  12. Malignant primary germ-cell tumor of the brain

    International Nuclear Information System (INIS)

    Yamamoto, Toyoshiro; Sato, Shinichi; Nakao, Satoshi; Ban, Sadahiko; Namba, Koh

    1983-01-01

    The unusual case of a 15 year old boy with three discrete paraventricular germ-cell tumors is reported.FThe first tumor was located just lateral to the left thalamus and included a massive cystic part around it, the second tumor in the paraventricular region above the head of the left caudate nucleus and the third tumor in the medial part of the left parietal lobe.FTotal removal of all tumors was successfully accomplished in stages at four separate operations, namely, the first tumor was removed through the left transsylvian approach, the second tumor via left superior frontal gyrus and the third tumor via left superior frontal gyrus and left superior parietal lobule.FHistological examination revealed that the first tumor was teratoma, the second was choriocarcinoma and the third was germinoma.FPrimary germ-cell tumors of the brain can be divided into 5 groups: 1) germinoma; 2) embryonal carcinoma; 3) choriocarcinoma; 4) yolk-sac tumor; or 5) teratoma.FIn this case, a combination of three different histological patterns was seen. If malignant germ-cell tumor is supected on CT, aggressive extirpation should be done, not only to determine the exact diagnosis, but also to provide the basis for subsequent adjunctive therapy. (author)

  13. Morphologic classification of ductal breast tumors on ultrasound : differential diagnosis of benign and malignant tumors

    International Nuclear Information System (INIS)

    Won, Mi Sook; Chung, Soo Young; Yang, Ik; Lee, Yul; Park, Hai Jung; Lee, Myoung Hwan; Yoon, In Sook; Koh, Mi Gyoung

    1997-01-01

    To evaluate the morphologic differential diagnosis of benign and malignant ductal breast tumors, as seen on US US findings in 29 pathologically proven cases of ductal breast tumor were retrospectively reviewed. All patients were female and their mean age was 42 years. Nineteen tumors were benign and ten were malignant, and all ductal or cystic lesions showed solid masses. According to the location of the mural nodule, we classified the sonographic appearance of these tumors into three types:intraductal, intracystic and amorphic. The intraductal type was divided into three subtypes:incompletely obstructive, completely obstructive and multiple mural nodules. For the intracystic type, too, three subtypes were designated:the intracystic mural nodule (mural cyst), intracystic mural nodule with the duct (mural cyst+duct) and intracystic multiple mural nodules. The amorphic type is defined as an atypical ductal tumor with the mural nodule extending into adjacent parenchyma. The margin of the duct or cyst was smooth in 68.4% of benign, and irregular in 90% of malignant ductal tumors. Internal echogeneity of the duct or cyst usually showed homogeneity in both benign and malignant tumors. 73.7% of tumors connecting the duct were benign and 50% were malignant. In benign tumors, 52.6% of mural nodule had an irregular margin, while in malignant tumors, the corresponding proportion was 100%;both types usually showed heterogeneous hypoechogeneity. Among benign tumors, the most common morphologic type was the intraductal incompletely obstructive subtype (36.8%);among those that were malignant, the amorphic type was most common, accounting for 40% of tumors. No amorphic type was benign and no incompletely obstructive subtype was malignant. When ductal breast tumors are morphologically classified on the basis of sonographic findings, the intraductal incompletely obstructive subtype suggests benignancy, and the amorphic type, malignancy. The morphologic classification of ductal

  14. Curettage of benign bone tumors and tumor like lesions: A retrospective analysis

    Directory of Open Access Journals (Sweden)

    Zile Singh Kundu

    2013-01-01

    demonstrates the natural healing ability of bone without filling with bone grafts or bone graft substitutes. In selected sizes and locations of the benign lytic tumors and tumor like lesions extended curettage alone can be sufficient.

  15. Detection of lung tumor movement in real-time tumor-tracking radiotherapy

    International Nuclear Information System (INIS)

    Shimizu, Shinichi; Shirato, Hiroki; Ogura, Shigeaki; Akita-Dosaka, Hirotoshi; Kitamura, Kei; Nishioka, Takeshi; Kagei, Kenji; Nishimura, Masaji; Miyasaka, Kazuo

    2001-01-01

    Purpose: External radiotherapy for lung tumors requires reducing the uncertainty due to setup error and organ motion. We investigated the three-dimensional movement of lung tumors through an inserted internal marker using a real-time tumor-tracking system and evaluated the efficacy of this system at reducing the internal margin. Methods and Materials: Four patients with lung cancer were analyzed. A 2.0-mm gold marker was inserted into the tumor. The real-time tumor-tracking system calculates and stores three-dimensional coordinates of the marker 30 times/s. The system can trigger the linear accelerator to irradiate the tumor only when the marker is located within the predetermined 'permitted dislocation'. The value was set at ±1 to ±3 mm according to the patient's characteristics. We analyzed 10,413-14,893 data sets for each of the 4 patients. The range of marker movement during normal breathing (beam-off period) was compared with that during gated irradiation (beam-on period) by Student's t test. Results: The range of marker movement during the beam-off period was 5.5-10.0 mm in the lateral direction (x), 6.8-15.9 mm in the craniocaudal direction (y) and 8.1-14.6 mm in the ventrodorsal direction (z). The range during the beam-on period was reduced to within 5.3 mm in all directions in all 4 patients. A significant difference was found between the mean of the range during the beam-off period and the mean of the range during the beam-on period in the x (p=0.007), y (p=0.025), and z (p=0.002) coordinates, respectively. Conclusion: The real-time tumor-tracking radiotherapy system was useful to analyze the movement of an internal marker. Treatment with megavoltage X-rays was properly given when the tumor marker moved into the 'permitted dislocation' zone from the planned position

  16. Hilar location is an independent prognostic factor for recurrence in T1 renal cell carcinoma after nephrectomy.

    Science.gov (United States)

    Shim, Myungsun; Song, Cheryn; Park, Sejun; Kim, Aram; Choi, Seung-Kwon; Kim, Choung-Soo; Ahn, Hanjong

    2015-01-01

    We investigated the prognostic significance of tumor location at the renal hilum near the sinus structure on the recurrence in T1 renal cell carcinoma (RCC). A total of 1,818 T1 RCC patients who underwent radical (RN) or partial nephrectomy (PN) from 1997 to 2011 were retrospectively reviewed. A hilar tumor was defined as a tumor abutting the main renal artery and/or vein or its segmental branches, without invasion. We compared the recurrence-free survival (RFS) rates between hilar and nonhilar T1 RCC and analyzed predictors of RFS after nephrectomy. Patients with hilar tumors showed a poorer 5-year RFS compared with nonhilar tumors both in T1a (89.7 vs. 98.5 %, p hilar tumors were associated with lower 5-year RFS (87.6 vs. 97.2 % for RN, 78.1 vs. 98.2 % for PN, both p hilar tumor, PN was associated with poorer 5-year RFS than RN (79.5 vs. 93.0 %, p hilar location remained as an independent predictor of recurrence in both T1a and T1b tumors (both p = 0.001). Hilar tumors show a higher recurrence rate than nonhilar counterparts in T1 RCC. In T1a hilar tumors, PN demonstrated poorer RFS than RN. Potential intrinsic renal anatomical or lymphovascular structural differences as well as differences in cancer characteristics need further investigations.

  17. Treatment and outcomes of tumor-induced osteomalacia associated with phosphaturic mesenchymal tumors: retrospective review of 12 patients.

    Science.gov (United States)

    Zuo, Qing-Yao; Wang, Hong; Li, Wei; Niu, Xiao-Hui; Huang, Yan-Hong; Chen, Jia; You, Yu-Hua; Liu, Bao-Yue; Cui, Ai-Min; Deng, Wei

    2017-09-21

    Tumor-induced osteomalacia (TIO) is a rare paraneoplastic syndrome characterized by severe hypophosphatemia and osteomalacia. Nonspecific symptoms make the diagnosis elusive. In addition, locating the responsible tumor(s) is challenging. The aim of this study was to investigate the clinical management and outcomes of TIO. The clinical features, diagnostic procedures, treatment, and outcomes of 12 patients were reviewed retrospectively. The cohort comprised six men and six women (mean age 45.5 ± 9.9 years, range 23-61 years). The mean duration of disease was 3.7 ± 2.6 years. All patients manifested progressive bone pain, muscle weakness, and/or difficulty walking. Serum phosphorus concentrations were low in all patients (mean 0.42 ± 0.12 mmol/L). Technetium-99m octreotide scintigraphy was performed in 11 patients and showed lesions in the right distal femur, left femoral head, and right tibial plateau, respectively, in three patients. Magnetic resonance imaging (MRI) was negative for lesions in one patient. Two patients underwent biopsies that showed negative histopathology. Two patients, at 2 years and 8 months, respectively, after having negative technetium-99m octreotide studies, underwent 18 F-fluorodeoxyglucose positron emission tomography/computed tomography (CT), which revealed lesions in the sacrum and soft tissue of the left palm, respectively. One tumor was detected by CT and MRI. Overall, lesion sites were the head (two patients, 16.7%), thoracic and lumbar region (two, 16.7%), pelvis (three, 25%), lower limbs (four, 33.3%), and upper limbs (one, 8.3%). All patients underwent surgery, and histopathology showed phosphaturic mesenchymal tumors in each. Postoperatively, serum phosphorus concentrations normalized within 2-7 days in 11 patients. With follow-ups of 1-41 months, surgery was effective in 10 patients. One patient developed local recurrence and another had metastases. Locating tumors responsible for tumor-induced osteomalacia is

  18. Efficacy and complications of radiotherapy of anterior visual pathway tumors

    International Nuclear Information System (INIS)

    Capo, H.; Kupersmith, M.J.

    1991-01-01

    A progressive disturbance in visual acuity or visual field, along with an unexplained optic nerve atrophy, suggests the possibility of a tumor. Tumors that frequently affect the anterior visual pathway include primary optic nerve sheath meningiomas, intracranial meningiomas, optic gliomas, pituitary tumors, and craniopharyngiomas. The location of these tumors sometimes prohibits a complete surgical excision that might jeopardize the visual system. Radiation therapy, however, can be beneficial in these cases. This article reviews the indications for radiotherapy of tumors that involve the anterior visual pathway, along with the possible complications. Cases that present the effect of radiation therapy and radiation damage are presented.131 references

  19. Central neurocytomas of uncommon locations: report of two cases Localizações incomuns do neurocitoma central: relato de dois casos

    Directory of Open Access Journals (Sweden)

    Francinaldo Lobato Gomes

    2006-12-01

    Full Text Available We report two patients with central neurocytomas at an uncommon location in the brain. The first, a 58-year-old man presenting with signs and symptoms of increased intracranial pressure, had a tumor located at the pineal region. The second, a 21-year-old woman with tumor in the aqueductal region had worsening migraine-like headaches and diplopia. Both patients had obstructive hydrocephalus treated by neuroendoscopic third ventriculostomy and biopsy of the tumors. No additional treatment was done. We conclude that neurocytomas should be considered in the differential diagnosis of tumors located in the pineal and aqueductal regions.Relatamos dois pacientes com neurocitoma central com localização incomum no sistema nervoso central. O primeiro, 58 anos, masculino, apresentava sinais e sintomas de hipertensão intracraniana, tinha um tumor na região da pineal. O segundo, feminino, 21 anos, tinha um tumor na região do aqueduto de Sylvius e apresentava cefaléia migranosa progressiva e diplopia. Ambos apresentavam hidrocefalia obstrutiva tratada com terceiroventriculostomia endoscópica e biópsia da lesão. Não foi feito tratamento adicional. Concluimos que os neurocitomas devem ser considerados no diagnóstico diferencial de tumores localizados na região da pineal e do aqueduto.

  20. Ultrasonic thermometry for nuclear power plants

    International Nuclear Information System (INIS)

    Saravana Kumar, S.; Arunraj, A.L.R.; Swaminathan, K.

    2013-01-01

    Ultrasonic transducer provides a method of measurement of temperature in industrial tanks and boilers containing different liquids with varied salt content. This method is used to measure the average temperature continuously where other traditional methods available do not offer. Traditional methods used for temperature measurement like infrared thermometers, thermocouples, measures temperature at a single location. Numerous thermocouples are to be fixed at various part of the boiler in order to measure the temperature of the entire boiler, which incurs high cost. Reliability of the system decreases, with increasing number of thermocouples. When they fail at a point, the time incurred in finding the faulty part or faulty thermocouple is high. Ultrasonic transducer provides continuous measurement for all different characteristic liquids with higher accuracy and lesser response time. Fault location and clearance time is also less in ultrasonic measurement method, since only a couple of transducers used for the entire boiler structure. Additionally ultrasonic thermometry along support measuring electronic system can be built of low cost. (author)

  1. Occurrence and location of Transmissible Venereal Tumors in Dogs seen at the Universidade Federal Rural do Rio de Janeiro Veterinary Hospital: Oncology Sector between 2010 and 2014.

    Directory of Open Access Journals (Sweden)

    Dayane Caicó Collares Araujo

    2016-09-01

    Full Text Available ABSTRACT. Araujo D.C.C., Antonioli T., Costa T.S., de Carvalho J.R.G., Laguna A.G.V., Ramadinha R.H.R. & Fernandes J.I. Occurrence and location of Transmissible Venereal Tumors in Dogs seen at the Universidade Federal Rural do Rio de Janeiro Veterinary Hospital: Oncology Sector between 2010 and 2014. [Ocorrência e localização do Tumor Venéreo Transmissível em cães atendidos entre 2010 e 2014 no Setor de Oncologia do Hospital Veterinário da Universidade Federal Rural do Rio de Janeiro, Brasil.] Revista Brasileira de Medicina Veterinária, 38(3:277-280, 2016. Programa de Residência em Medicina Veterinária, Instituto de Veterinária, Universidade Federal Rural do Rio de Janeiro, BR-465, Km 7, Seropédica, RJ 23851-970, Brasil. E-mail: dayanecaico@hotmail.com The Transmissible Venereal Tumor (TVT is a round cell neoplasm mostly affecting the genital of dogs. They can affect both sexes, and most animals are sexually active. Metastases, which occur in less than 5% of cases, occur through lymphatic or hematogenous. Diagnosis can be made by cytology and the most effective treatment is chemotherapy with vincristine sulfate. This study reports the occurrence of TVT from January 2010 to December 2014 in the UFRRJ Veterinary Hospital at the Oncology sector; clinical records were reviewed: 1,522 animals were seen and 123 (8.08% presented TVT. Of 123 animals afflicted, 71.54% were adults, 23.57% were senior and 4.87% had less than a year. A higher frequency of females (74 was observed, when compared to males (49. A higher incidence in mutts (78.05% was found, followed by poodles (7.32%, pinscher and Labrador (3.25%. Genital location was most common (79.04%, followed by a genito-cutaneous presentation (8.94%, nasal (5.69%, cutaneous (5.69% and ocular (0.81%. It can be linked with large quantities of stray dogs and poor animal control policies in the region.

  2. Study of Thermocurrents in ILC cavities via measurements of the Seebeck Effect in niobium, titanium, and stainless steel thermocouples

    Energy Technology Data Exchange (ETDEWEB)

    Cooley, Victoria [Univ. of Wisconsin, Madison, WI (United States)

    2014-01-01

    The goals of Fermilab’s Superconductivity and Radio Frequency Development Department are to engineer, fabricate, and improve superconducting radio frequency (SCRF) cavities in the interest of advancing accelerator technology. Improvement includes exploring possible limitations on cavity performance and mitigating such impediments. This report focuses on investigating and measuring the Seebeck Effect observed in cavity constituents titanium, niobium, and stainless steel arranged in thermocouples. These junctions exist between cavities, helium jackets, and bellows, and their connection can produce a loop of electrical current and magnetic flux spontaneously during cooling. The experimental procedure and results are described and analyzed. Implications relating the results to cavity performance are discussed.

  3. Surgery of resectable nonfunctioning neuroendocrine pancreatic tumors.

    Science.gov (United States)

    Dralle, Henning; Krohn, Sabine L; Karges, Wolfram; Boehm, Bernhard O; Brauckhoff, Michael; Gimm, Oliver

    2004-12-01

    Nonfunctioning neuroendocrine pancreatic tumors (NFNEPTs) comprise about one-third of pancreatic endocrine tumors. Based on immunohistochemistry, nonfunctioning tumors are difficult to distinguish from functioning ones; therefore the final diagnosis is basically the result of a synopsis of pathology and clinical data. Owing to their incapacity to produce hormone-dependent symptoms, NFNEPTs are detected incidentally or because of uncharacteristic symptoms resulting from local or distant growth. About two-thirds of NFNEPTs are located in the pancreatic head, so jaundice may be a late symptom of this tumor. Modern diagnostic procedures are best applied by a stepwise approach: first endoscopic ultrasonography and computed tomography/magnetic resonance imaging followed by somatostatin receptor scintigraphy or positron emission tomography (or both). Due to significant false-positive and false-negative findings, for decision-making the latter should be confirmed by a second imaging modality. Regarding indications for surgery and the surgical approach to the pancreas, three pancreatic manifestations of NFNEPTs can be distinguished: (1) solitary benign non-multiple endocrine neoplasia type 1 (non-MEN-1); (2) multiple benign MEN-1; and (3) malignant NFNEPTs. Reviewing the literature and including our experience with 18 NFNEPTs (8 benign, 10 malignant) reported here, the following conclusions can be drawn: (1) Solitary benign non-MEN-1 NFNEPTs can be removed by enucleation or by pancreas-, spleen-, and duodenum-preserving techniques in most cases. The choice of surgical technique depends on the location and site of the tumor and its anatomic relation to the pancreatic duct. (2) With multiple benign MEN-1 NFNEPTs, because of the characteristics of the underlying disease a preferred, more conservative concept (removal of only macrolesions) competes with a more radical procedure (left pancreatic resection with enucleation of head macrolesions). Further studies are necessary to

  4. Sex Cord-Gonadal Stromal Tumor of the Rete Testis

    Directory of Open Access Journals (Sweden)

    Kamran P. Sajadi

    2009-01-01

    Full Text Available A 34-year-old tetraplegic patient with suppurative epididymitis was found on follow-up examination and ultrasonography to have a testicular mass. The radical orchiectomy specimen contained an undifferentiated spindled sex cord-stromal tumor arising in the rete testis. Testicular sex cord-stromal tumors are far less common than germ cell neoplasms and are usually benign. The close relationship between sex cords and ductules of the rete testis during development provides the opportunity for these uncommon tumors to arise anatomically within the rete tesis. This undifferentiated sex cord-stromal tumor, occurring in a previously unreported location, is an example of an unusual lesion mimicking an intratesticular malignant neoplasm.

  5. Sex cord-gonadal stromal tumor of the rete testis.

    Science.gov (United States)

    Sajadi, Kamran P; Dalton, Rory R; Brown, James A

    2009-01-01

    A 34-year-old tetraplegic patient with suppurative epididymitis was found on follow-up examination and ultrasonography to have a testicular mass. The radical orchiectomy specimen contained an undifferentiated spindled sex cord-stromal tumor arising in the rete testis. Testicular sex cord-stromal tumors are far less common than germ cell neoplasms and are usually benign. The close relationship between sex cords and ductules of the rete testis during development provides the opportunity for these uncommon tumors to arise anatomically within the rete tesis. This undifferentiated sex cord-stromal tumor, occurring in a previously unreported location, is an example of an unusual lesion mimicking an intratesticular malignant neoplasm.

  6. n⁺ GaAs/AuGeNi-Au Thermocouple-Type RF MEMS Power Sensors Based on Dual Thermal Flow Paths in GaAs MMIC.

    Science.gov (United States)

    Zhang, Zhiqiang; Liao, Xiaoping

    2017-06-17

    To achieve radio frequency (RF) power detection, gain control, and circuit protection, this paper presents n⁺ GaAs/AuGeNi-Au thermocouple-type RF microelectromechanical system (MEMS) power sensors based on dual thermal flow paths. The sensors utilize a conversion principle of RF power-heat-voltage, where a thermovoltage is obtained as the RF power changes. To improve the heat transfer efficiency and the sensitivity, structures of two heat conduction paths are designed: one in which a thermal slug of Au is placed between two load resistors and hot junctions of the thermocouples, and one in which a back cavity is fabricated by the MEMS technology to form a substrate membrane underneath the resistors and the hot junctions. The improved sensors were fabricated by a GaAs monolithic microwave integrated circuit (MMIC) process. Experiments show that these sensors have reflection losses of less than -17 dB up to 12 GHz. At 1, 5, and 10 GHz, measured sensitivities are about 63.45, 53.97, and 44.14 µ V/mW for the sensor with the thermal slug, and about 111.03, 94.79, and 79.04 µ V/mW for the sensor with the thermal slug and the back cavity, respectively.

  7. Two- versus four-handed techniques for endonasal resection of orbital apex tumors.

    Science.gov (United States)

    Craig, John R; Lee, John Y K; Petrov, Dmitriy; Mehta, Sonul; Palmer, James N; Adappa, Nithin D

    2015-01-01

    Open versus endonasal resection of orbital apex (OA) tumors is generally based on tumor size, location, and pathology. For endonasal resection, two- and four-handed techniques have been reported, but whether one technique is more optimal based on these tumor features has not been evaluated. To determine whether two- versus four-handed techniques result in better outcomes after endoscopic resection of OA tumors, and whether either technique is better suited for intra- versus extraconal location and for benign versus malignant pathology. A retrospective review of all expanded endonasal approaches for OA tumors was performed at a single institution from 2009 to 2013. A PubMed database search was also performed to review series published on endonasal OA tumor resection. Across all the cases reviewed, the following data were recorded: two- versus four-handed techniques, intra- versus extraconal tumor location, and benign versus malignant pathology. The relationship between these variables and resection extent was analyzed by the Fisher exact test. Postoperative visual status and complications were also reviewed. Ten cases from the institution and 94 cases from 17 publications were reviewed. Both two- and four-handed techniques were used to resect extra- and intraconal OA tumors, for both benign and malignant pathology. Four-handed techniques included a purely endonasal approach and a combined endonasal-orbital approach. On univariate analysis, the strongest predictor of complete resection was benign pathology (p = 0.005). No significant difference was found between the extent of resection and a two- versus a four-handed technique. Visual status was improved or unchanged in 94% of cases, and other complications were rare. Benign tumors that involve the medial extraconal and posterior inferomedial intraconal OA can be treated by either two- or four-handed endonasal techniques. Selecting two- versus four-handed techniques and endonasal versus endonasal-orbital four

  8. Osteogenic tumors of bone; Osteogene Tumoren

    Energy Technology Data Exchange (ETDEWEB)

    Jobke, B. [Deutsches Krebsforschungszentrum (DKFZ), Abtl. Radiologie, Heidelberg (Germany); Werner, M. [MVZ des HELIOS Klinikum Emil von Behring, Orthopaedische Pathologie - Referenzzentrum, Institut fuer Gewebediagnostik Berlin, Berlin (Germany)

    2016-06-15

    Osteogenic tumors include malignant and benign tumors that produce tumor osteoid and/or bone tissue. Osteosarcoma is the most common malignant bone tumor, especially in children and young adults. The entities with their characteristic morphological features are described to enable the reader to come to a diagnosis and differential diagnosis on the basis of patient age, history and predominant location of the tumor. For this review we selectively used mainly large published patient cohorts. Our own and externally published data on widely accepted tumor criteria were also compared. Detection is the initial diagnostic step for an osseous lesion, and is determined by the sensitivity of the method applied. Plain X-ray films in two planes and CT are the basics in the radiological toolkit for osteogenic tumors. For evaluation of local tumor extension and biopsy planning MRI or scintigraphy should be combined. MRI as a stand-alone diagnostic tool is insufficient. For malignant bone tumors staging should be performed, applying a variable combination of thoracic CT, MRI, scintigraphy, and positron emission tomography (PET). Osteosarcoma, along with Ewing sarcoma and chondrosarcoma, are the most common malignant bone tumors; all sub-entities are significantly rarer. Among benign bone tumors, osteoid osteomas have the highest incidence, presenting with typical pain, location, and age predilection. Diagnostics and treatment of malignant bone tumors should preferably be performed in specialized centers because of significant therapeutic implications for patients. In uncertain cases, a second opinion should always be obtained. (orig.) [German] Osteogene Tumoren umfassen maligne und benigne Tumoren, die eine tumoreigene Produktion von Osteoid und/oder Knochengewebe aufweisen. Das Osteosarkom ist der haeufigste maligne Knochentumor v. a. bei Kindern und jungen Erwachsenen. Es werden die Entitaeten mit ihren morphologischen Charakteristika beschrieben, um anhand wichtiger

  9. Refractory epilepsy in children with brain tumors. The urgency of neurosurgery

    OpenAIRE

    Bernardino, Marília Rosa Abtibol; Funayama, Carolina; Hamad, Ana Paula Andrade; Machado, Hélio; Sakamoto, Américo; Thome, Ursula; Terra, Vera Cristina; Santos, Antonio Carlos dos; Serafani, Luciano Nader; Calixto, Nathalia Cunha; Silva, Huria Shalom Monturil de Carvalho

    2016-01-01

    ABSTRACT In order to verify indications for surgery, 27 patients with refractory epileptic seizures and brain tumor, aged up to 19 years at the time of surgery, were studied between 1996 and 2013 and followed up for at least one year. The mean interval between the onset of seizures and the diagnosis of the tumor was 3.6 years, and from diagnosis to the surgery, 18 months. The location of the tumor was in the temporal lobe in 16, with ganglioglioma and dysembryoplastic neuroepithelial tumors b...

  10. Localized giant cell tumors in the spinal column radiologic presentation

    International Nuclear Information System (INIS)

    Fernandez Echeverria, M.A.; Parra Blanco, J.A.; Pagola Serrano, M.A.; Mellado Santos, J.M.; Bueno Lopez, J.; Gonzalez Tutor, A.

    1994-01-01

    Given the uncommonness of the location of giant cell tumors (GCT) in the spinal column and the limited number of studies published, we present a case of GCT located in the spinal column, which involved both vertebral bodies and partially destroyed the adjacent rib. (Author)

  11. A Rare Case of Malignant Glomus Tumor of the Esophagus

    Directory of Open Access Journals (Sweden)

    Gurvinder Singh Bali

    2013-01-01

    Full Text Available Glomus tumors are rare neoplasms that usually occur on the hands in a subungual location, or sometimes in palms, wrists or soles of the feet. They are described as purple/pink tiny painful lesions with a triad of pain, local point tenderness, and cold hypersensitivity. They are almost always benign, but rare malignant variants have been reported. They have also been reported to be present at unusual locations, like the lung, stomach, or liver. Gastrointestinal glomus tumors are extremely rare tumors and very few cases have been reported in the literature. Most that have been reported were usually benign in nature. A rare esophageal glomangioma, mimicking a papilloma, was reported in 2006. We report a case of glomangiosarcoma (malignant glomus tumor in a 49-year-old female, who presented with symptoms of dysphagia including some spasm and hoarseness and subjective unintentional weight loss. On endoscopic exam, she was found to have a distal esophageal mass with malignant features. Radiologically, the mass had a size of about 8 cm on the CT scan without evidence of metastases. Pathology and immunostaining of the biopsy showed features resembling a malignant glomus tumor. She underwent an endoscopic and laparoscopic staging of the tumor along with ultrasound. Based on the laparoscopic findings, which were consistent with the preoperative diagnosis, she was scheduled for an esophagectomy. Histopathology and immunophenotypic features of the excised mass were consistent with a diagnosis of malignant glomus tumor.

  12. [Neuronavigator-guided microsurgery for resection of brain tumors].

    Science.gov (United States)

    Zhang, Xiang; Zhang, Jianning; Fei, Zhou; Wu, Jingwen; Fu, Luoan; Qu, Yan; Liu, Weiping; Wang, Zhanxiang; Yang, Lisun; He, Xiaosheng; Zhen, Haining; Gao, Dakuan; Cao, Weidong; Liang, Jingwen

    2002-02-25

    To study locating accuracy for the brain tumors and their peri-structures by the neuronavigator and elucidate the microsurgical effects. 65 patients with intracranial tumors were microsurgically treated by the application of Stealth Station and Vector Vision system. The treatment effects were summarized and the neuronavigational accuracy was discussed. After mean fiducial error (MFE) and sustained accuracy (SA) were satisfied. Total tumor removal was achieved in 63 cases (97.0%), subtotal removal in 2 cases (3.0%). The neurological functions were improved in 56 cases (86.2%), unchanged obviously in 9 cases (13.8%). No case deteriorated and died in the group. Navigation systems are reliable and accurate in making microneurosurgical plans for brain tumors. And they can provide tracing of the tumor in the operation and guide the operator's manipulation. The techniques, which help total removal of the tumors and reduce the postoperative complications, are very useful in guarantee operation effects.

  13. Clinical Efficacy of Various Diagnostic Tests for Small Bowel Tumors and Clinical Features of Tumors Missed by Capsule Endoscopy

    Directory of Open Access Journals (Sweden)

    Jung Wan Han

    2015-01-01

    Full Text Available Background. We aimed to evaluate the efficacy of various diagnostic tools such as computerized tomography (CT, small bowel follow-through (SBFT, and capsule endoscopy (CE in diagnosing small bowel tumors (SBTs. Additionally, we aimed to evaluate the clinical features of SBTs missed by CE. Methods. We retrospectively studied 79 patients with histologically proven SBT. Clinical data were analyzed with particular attention to the efficacy of CT, SBFT, and CE in detecting SBT preoperatively. We also analyzed the clinical features of SBTs missed by CE. Results. The most common symptoms of SBT were bleeding (43% and abdominal pain (13.9%. Diagnostic yields were as follows: CT detected 55.8% of proven SBTs; SBFT, 46.1%; and CE, 83.3%. The sensitivity for detecting SBTs was 40.4% for CT, 43.9% for SBFT, and 79.6% for CE. Two patients with nondiagnostic but suspicious findings on CE and seven patients with negative findings on CE were eventually found to have SBT. These nine patients were eventually diagnosed with gastrointestinal stromal tumor (4, small polyps (3, inflammatory fibroid polyp (1, and adenocarcinoma (1. These tumors were located in the proximal jejunum (5, middle jejunum (1, distal jejunum (1, and proximal ileum (1. Conclusion. CE is more efficacious than CT or SBFT for detecting SBTs. However, significant tumors may go undetected with CE, particularly when located in the proximal jejunum.

  14. Incidentally detected gastrointestinal stromal tumor: A case report

    Directory of Open Access Journals (Sweden)

    Tolga Canbak

    2017-12-01

    Full Text Available Gastrointestinal stromal tumors (GIST are mesenchymal tumors located primarily in the gastrointestinal tract. We aimed to present a case report of GIST incidentally detected during laparoscopic cholecystectomy.A 60-year-old woman was admitted to the emergency room due to abdominal pain for one day. The physical examination revealed sensitivity on the right upper quadrant. In the laboratory examinations, white blood cell count 6,490 k/uL, hemoglobin 12 g/dL, hematocrit 35% and other biochemical tests were normal. Abdominal ultrasound revealed hydropic gallbladder, several gallstones with a maximum diameter of 15 mm and pericholecystic fluid collection was present. Laparoscopic cholecystectomy was planned due to acute cholecystitis. In exploration, beside the presence of acute cholecystitis, a mass of approximately 5 cm, located 15 cm distal to the ligament of Treitz was detected. Laparoscopic cholecystectomy was performed. Conversion to open laparotomy was done; small intestine resection with end-to-end anastomosis was performed. Gastrointestinal stromal tumor with CD117, CD34 and S100 positivity was detected on histopathologic examination.It is thought that GISTs are mesenchymal tumors originating from precursors of Kajal cells. GISTs are usually detected in their 60s. The first option for treatment is surgical resection.

  15. Simulating tumor growth in confined heterogeneous environments

    International Nuclear Information System (INIS)

    Gevertz, Jana L; Torquato, Salvatore; Gillies, George T

    2008-01-01

    The holy grail of computational tumor modeling is to develop a simulation tool that can be utilized in the clinic to predict neoplastic progression and propose individualized optimal treatment strategies. In order to develop such a predictive model, one must account for many of the complex processes involved in tumor growth. One interaction that has not been incorporated into computational models of neoplastic progression is the impact that organ-imposed physical confinement and heterogeneity have on tumor growth. For this reason, we have taken a cellular automaton algorithm that was originally designed to simulate spherically symmetric tumor growth and generalized the algorithm to incorporate the effects of tissue shape and structure. We show that models that do not account for organ/tissue geometry and topology lead to false conclusions about tumor spread, shape and size. The impact that confinement has on tumor growth is more pronounced when a neoplasm is growing close to, versus far from, the confining boundary. Thus, any clinical simulation tool of cancer progression must not only consider the shape and structure of the organ in which a tumor is growing, but must also consider the location of the tumor within the organ if it is to accurately predict neoplastic growth dynamics

  16. Clinical impact of anatomo-functional evaluation of brain function during brain tumor surgery

    International Nuclear Information System (INIS)

    Mikuni, Nobuhiro; Kikuchi, Takayuki; Matsumoto, Atsushi; Yokoyama, Yohei; Takahashi, Jun; Hashimoto, Nobuo

    2009-01-01

    To attempt to improve surgical outcome of brain surgery, clinical significance of anatomo-functional evaluation of brain function during resection of brain tumors was assessed. Seventy four patients with glioma located near eloquent areas underwent surgery while awake. Intraoperative tractography-integrated functional neuronavigation and cortical/subcortical electrical stimulation were correlated with clinical symptoms during and after resection of tumors. Cortical functional areas were safely removed with negative electric stimulation and eloquent cortices could be removed in some circumstances. Subcortical functional mapping was difficult except for motor function. Studying cortical functional compensation allows more extensive removal of brain tumors located in the eloquent areas. (author)

  17. Salivary gland tumors in a Brazilian population: a retrospective study of 124 cases

    OpenAIRE

    Vargas, Pablo Agustin; Gerhard, Renê; Araújo Filho, Vergílius J. F.; Castro, Inês Vieira de

    2002-01-01

    Salivary gland tumors constitute a highly heterogeneous histopathologic group. There are few epidemiological studies of large series of benign and malignant salivary gland tumors in Brazil. MATERIAL AND METHODS: Hospital records of 124 patients with salivary gland tumors diagnosed from January 1993 to December 1999 were reviewed. The patients were analyzed according to gender, age, size, location, and histopathology of the tumor. RESULTS AND CONCLUSIONS: Patients with benign and malignant tum...

  18. Thermocouple and infrared sensor-based measurement of temperature distribution in metal cutting.

    Science.gov (United States)

    Kus, Abdil; Isik, Yahya; Cakir, M Cemal; Coşkun, Salih; Özdemir, Kadir

    2015-01-12

    In metal cutting, the magnitude of the temperature at the tool-chip interface is a function of the cutting parameters. This temperature directly affects production; therefore, increased research on the role of cutting temperatures can lead to improved machining operations. In this study, tool temperature was estimated by simultaneous temperature measurement employing both a K-type thermocouple and an infrared radiation (IR) pyrometer to measure the tool-chip interface temperature. Due to the complexity of the machining processes, the integration of different measuring techniques was necessary in order to obtain consistent temperature data. The thermal analysis results were compared via the ANSYS finite element method. Experiments were carried out in dry machining using workpiece material of AISI 4140 alloy steel that was heat treated by an induction process to a hardness of 50 HRC. A PVD TiAlN-TiN-coated WNVG 080404-IC907 carbide insert was used during the turning process. The results showed that with increasing cutting speed, feed rate and depth of cut, the tool temperature increased; the cutting speed was found to be the most effective parameter in assessing the temperature rise. The heat distribution of the cutting tool, tool-chip interface and workpiece provided effective and useful data for the optimization of selected cutting parameters during orthogonal machining.

  19. Thoracoabdominal peripheral primitive neuroectodermal tumors in childhood: radiological features

    International Nuclear Information System (INIS)

    Schulman, H.; Laufer, L.; Newman-Heinman, N.; Kurtzbart, E.; Maor, E.; Zirkin, H.

    2000-01-01

    Peripheral primitive neuroectodermal tumors (PNET) are extremely uncommon, malignant neoplasms affecting mostly children and young adults. We retrospectively reviewed the clinical data and radiological studies of four such cases. All cases were pathologically proven. Plain films, US, and CT scans were used. The youngest child had a huge pelvic tumor and two adolescents each had a chest wall (Askin) tumor. The fourth patient had a most unusual location of the PNET in the anterior mediastinum. The CT findings are emphasized. We emphasize that the markedly abnormal CT findings are not specific for PNET. (orig.)

  20. Odontogenic tumors: analysis of 127 cases Tumores odontogênicos: análise de 127 casos

    Directory of Open Access Journals (Sweden)

    Jean Nunes SANTOS

    2001-12-01

    Full Text Available One hundred and twenty-seven cases of histologically confirmed odontogenic tumors were retrieved from a total of 5,289 oral and maxillary lesions diagnosed at the Division of Oral Pathology, Federal University of Rio Grande do Norte, during a period of 30 years (l970-l999. The most common histological diagnosis was odontoma (50.40%, followed by ameloblastoma (30.70%. The prevalence of odontogenic tumors was greater in females and the peak incidence occurred in the second and third decades of life. The main anatomical location was the mandible, and no malignant tumors were found.De uma série de 5.289 casos de lesões orais e dos maxilares diagnosticadas no Laboratório de Patologia Oral da Faculdade de Odontologia da Universidade Federal do Rio Grande do Norte no período de 30 anos (1970-1999, foram analisados 127 casos de tumores odontogênicos confirmados histologicamente. A lesão mais freqüente foi o odontoma (50,40% seguida pelo ameloblastoma (30,70%. A prevalência de tumores odontogênicos foi maior nas mulheres e o pico de incidência ocorreu na segunda e terceira décadas de vida. A localização anatômica mais comum foi a mandíbula e não foram encontrados casos de tumores malignos.

  1. Application of argon-helium cryoablation in resection of intracranial tumors

    Directory of Open Access Journals (Sweden)

    Yu-hao ZHOU

    2017-07-01

    Full Text Available Objective To summarize the curative effect of argon-helium cryoablation in resection of intracranial tumors.  Methods and Results A total of 11 patients with primary intracranial tumors, including 7 cases of glioma and 4 cases of meningioma, were enrolled in this study. The tumor was located in left frontal lobe in 4 cases, left fronto-parietal lobe in 2 cases, left temporal lobe in 2 cases and right temporo-parietal lobe in 3 cases. Argon-helium cryoablation was used to assist intracranial tumor resection. Among 7 cases of glioma, 4 cases were totally removed and 3 cases were partially resected. Four cases of meningioma were totally removed. The average intraoperative blood loss was 80 ml, and average operation time was 80 min. Postoperative clinical symptoms were improved, and head CT or MRI showed no rebleeding. Patients were followed up for an average of 4 years, and none of them suffered from operation-related or postoperative complications such as intracranial infection, or tumor recurrence.  Conclusions Argon - helium cryoablation is suitable for intracranial tumors with different diameters and in different locations. It is safe and effective, with few operation-related or postoperative complications, less rebleeding and low risk of recurrence, which is a highly efficient and relatively low?cost assistant surgical method. DOI: 10.3969/j.issn.1672-6731.2017.06.011

  2. [Neuronavigator-assisted microsurgical resection of glioma located in cerebral functional areas].

    Science.gov (United States)

    Su, Guohui; Liu, Zhixiong; Huo, Lei; Li, Chuntao; Zhang, Mingyu

    2017-05-28

    To evaluate value of neuronavigator-assisted microsurgery of glioma located in cerebral functional areas.
 Methods: Patients with glioma located in cerebral functional areas were underwent operation in Xiangya Hospital. Of 64 patients, 34 patients were performed neuronavigator-assisted microsurgery, and 30 were underwent routine surgical operation.
 Results: The neuronavigator-assisted microsurgery group showed high complete resection rate with low neurological deficit and cerebral edema compared with the routine surgical group (PNeuronavigator-assisted microsurgery is effective and characterized by accurate location, personalized operative incision design, and higher rate of tumor resection.

  3. Benign metastasizing leiomyoma in triple location: lungs, parametria and appendix

    Directory of Open Access Journals (Sweden)

    Renata Raś

    2016-07-01

    Full Text Available Benign metastasizing leiomyoma (BML usually are situated in one organ, most often in lungs. BML patients typically have a history of uterine leiomyoma treated with hysterectomy, myomectomy or subtotal hysterectomy. The aim of the study was to present the case of a 53-year-old woman with triple location in the lungs, parametria and appendix. She had undergone a myomectomy 26 years earlier. In 2015, she was admitted to the surgical department because of abdominal pain, whereupon a cholecystectomy was performed. CT scans showed pelvic mass with pulmonary metastasis. Upon discharge the patient was referred to the Gynecology Clinic, where a laparotomy was performed. The intraoperative findings were: 1 uterus with multiple leiomyomas, 2 four tumors in the parametria, 3 tumor connected to the appendix. A subtotal hysterectomy, with a bilateral salpingo-oophorectomy, removal of the tumors from the parametria and appendectomy was performed. Pathology confirmed the diagnosis based on morphology and immunohistochemical staining (strongly positive for estrogen receptors and SMA, while Ki67 was very low, below 1%. Upon postoperative recovery, the patient was referred to the Thoracic Surgery Department. During the thoracotomy, multiple nodes, surrounded by lung parenchyma, were revealed. Wedge resection was performed, for localized pulmonary lesions, and sent for pathological examination. The final pathological diagnosis was benign metastasizing leiomyomatosis. In conclusion, the triple location of BML could possibly be a result of a parallel different metastasizing mechanism, although it is impossible to exclude one mechanism, which may be the cause of the metastases in three locations.

  4. Myxoid Neurothekeoma: A Rare Soft Tissue Tumor of Hand in a ...

    African Journals Online (AJOL)

    Nerve sheath myxoma (neurothekeoma) is an uncommon benign soft tissue tumor of the peripheral nerves with fairly distinctive histological features. It is commonly located on the upper extremities or the head and the neck.[1] Histologic variants of neurothekeoma include myxoid, cellular, and mixed tumors. A recent ...

  5. The novel RAF1 mutation p.(Gly361Ala) located outside the kinase domain of the CR3 region in two patients with Noonan syndrome, including one with a rare brain tumor.

    Science.gov (United States)

    Harms, Frederike L; Alawi, Malik; Amor, David J; Tan, Tiong Y; Cuturilo, Goran; Lissewski, Christina; Brinkmann, Julia; Schanze, Denny; Kutsche, Kerstin; Zenker, Martin

    2018-02-01

    Noonan syndrome is characterized by typical craniofacial dysmorphism, postnatal growth retardation, congenital heart defect, and learning difficulties and belongs to the RASopathies, a group of neurodevelopmental disorders caused by germline mutations in genes encoding components of the RAS-MAPK pathway. Mutations in the RAF1 gene are associated with Noonan syndrome, with a high prevalence of hypertrophic cardiomyopathy (HCM). RAF1 mutations cluster in exons encoding the conserved region 2 (CR2), the kinase activation segment of the CR3 domain, and the C-terminus. We present two boys with Noonan syndrome and the identical de novo RAF1 missense variant c.1082G>C/p.(Gly361Ala) affecting the CR3, but located outside the kinase activation segment. The p.(Gly361Ala) mutation has been identified as a RAF1 allele conferring resistance to RAF inhibitors. This amino acid change favors a RAF1 conformation that allows for enhanced RAF dimerization and increased intrinsic kinase activity. Both patients with Noonan syndrome showed typical craniofacial dysmorphism, macrocephaly, and short stature. One individual developed HCM and was diagnosed with a disseminated oligodendroglial-like leptomeningeal tumor (DOLT) of childhood at the age of 9 years. While there is a well-established association of NS with malignant tumors, especially childhood hemato-oncological diseases, brain tumors have rarely been reported in Noonan syndrome. Our data demonstrate that mutation scanning of the entire coding region of genes associated with Noonan syndrome is mandatory not to miss rare variants located outside the known mutational hotspots. © 2017 Wiley Periodicals, Inc.

  6. Wilms tumor arising in extracoelomic paravertebral soft tissues.

    LENUS (Irish Health Repository)

    Mulligan, Linda

    2012-02-01

    Extrarenal Wilms tumor (ERWT) is a well-established entity which most commonly arises within the genitourinary tract, including intracoelomic paranephric soft tissue. Rarely, ERWT arises within teratoma, and it tends to occur predominantly in distinct settings, such as females with spinal defects and males with testicular teratomas. We report a unique ERWT arising within an extracoelomic teratoma of the paraspinal musculature, thereby expanding the range of reported locations for this unusual tumor.

  7. Giant cell tumor of the frontal sinus: case report

    Energy Technology Data Exchange (ETDEWEB)

    Matushita, Joao Paulo, E-mail: jpauloejulieta@gmail.com [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Hospital das Clinicas; Matushita, Julieta S.; Matushita Junior, Joao Paulo Kawaoka [Centro de Diagnostico por Imagem Dr. Matsushita, Belo Horizonte, MG (Brazil); Matushita, Cristina S. [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Hospital Universitario Clementino Fraga Filho; Simoes, Luiz Antonio Monteiro; Carvalho Neto, Lizando Franco de

    2013-06-15

    The authors report the case of a giant cell tumor of the frontal sinus in a 54-year-old male patient. This tumor location is rare, and this is the third case reported in the literature with radiographic documentation and histopathological confirmation. The patient underwent surgery, with curettage of frontal sinus and placement of a prosthesis. He died because a voluntary abrupt discontinuation of corticosteroids. (author)

  8. Primitive neuroectodermal tumor of the zygomaticoorbital complex: a rare location and ways of surgical repair of the area

    Directory of Open Access Journals (Sweden)

    Ch. R. Ragimov

    2015-01-01

    Full Text Available Primitive neuroectodermal tumor in the zygomaticoorbital region is a rare neoplasm of the head and neck. Due to the necessity for wide radical excision of a primary tumor, there may be serious functional and cosmetic disorders that substantially affect quality of life in patients. Restoration of this region is one of the challenges of reconstructive surgery because of the specific features of the relief of bone structures. The paper describes a clinical case of the site of primitive neuroectodermal tumor in the zygomaticoorbital complex and a method for repairing postresectional defect and completely recovering the function of the organ of vision and aesthetic parameters of the face.

  9. Dietary Patterns and Risk of Colorectal Cancer: Analysis by Tumor Location and Molecular Subtypes.

    Science.gov (United States)

    Mehta, Raaj S; Song, Mingyang; Nishihara, Reiko; Drew, David A; Wu, Kana; Qian, Zhi Rong; Fung, Teresa T; Hamada, Tsuyoshi; Masugi, Yohei; da Silva, Annacarolina; Shi, Yan; Li, Wanwan; Gu, Mancang; Willett, Walter C; Fuchs, Charles S; Giovannucci, Edward L; Ogino, Shuji; Chan, Andrew T

    2017-06-01

    Western and prudent dietary patterns have been associated with higher and lower risks of colorectal cancer (CRC), respectively. However, little is known about the associations between dietary patterns and specific anatomic subsites or molecular subtypes of CRC. We used multivariable Cox proportional hazards models to examine the associations between Western and prudent dietary patterns and CRC risk in the Health Professionals Follow-up Study and Nurses' Health Study. After up to 32 years of follow-up of 137,217 men and women, we documented 3260 cases of CRC. Among individuals from whom subsite data were available, we observed 1264 proximal colon, 866 distal colon, and 670 rectal tumors. Western diet was associated with an increased incidence of CRC (P trend pattern, we observed a RR of 0.86 for overall CRC (95% CI, 0.77-0.95; P trend  = .01), with similar trends at anatomic subsites. However, the trend appeared stronger among men than women. Among 1285 cases (39%) with tissue available for molecular profiling, Western diet appeared to be more strongly associated with some CRC molecular subtypes (no mutations in KRAS [KRAS wildtype] or BRAF [BRAF wildtype], no or a low CpG island methylator phenotype, and microsatellite stability), although formal tests for heterogeneity did not produce statistically significant results. Western dietary patterns are associated with an increased risk of CRC, particularly distal colon and rectal tumors. Western dietary patterns also appear more strongly associated with tumors that are KRAS wildtype, BRAF wildtype, have no or a low CpG island methylator phenotype, and microsatellite stability. In contrast, prudent dietary patterns are associated with a lower risk of CRC that does not vary according to anatomic subsite or molecular subtype. Copyright © 2017 AGA Institute. Published by Elsevier Inc. All rights reserved.

  10. Tumoral calcinosis presenting as an extradural mass: MR findings and pathological correlation

    Energy Technology Data Exchange (ETDEWEB)

    Iglesias, A.; Arias, M.; Brasa, J. [Unidad de Resonancia Magnetica (MEDTEC), Hospital Xeral-Cies, 36204 Vigo (Spain); Gonzalez, A. [Servicio de Anatomia Patologica, Hospital Xeral-Cies, 36204 Vigo (Spain); Conde, C. [Servicio de Neurocirugia, Hospital Xeral-Cies, 36204 Vigo (Spain)

    2002-09-01

    Two cases of idiopathic tumoral calcinosis presenting as an extradural mass are reported. There are few reports in the literature of this pathological process presenting as extradural masses, so both cases represent very unusual locations for tumoral calcinosis. Magnetic resonance imaging features and pathological correlation of these two cases are presented. Tumoral calcinosis might be considered as a rare but possible cause of extradural mass. (orig.)

  11. Tumoral calcinosis presenting as an extradural mass: MR findings and pathological correlation

    International Nuclear Information System (INIS)

    Iglesias, A.; Arias, M.; Brasa, J.; Gonzalez, A.; Conde, C.

    2002-01-01

    Two cases of idiopathic tumoral calcinosis presenting as an extradural mass are reported. There are few reports in the literature of this pathological process presenting as extradural masses, so both cases represent very unusual locations for tumoral calcinosis. Magnetic resonance imaging features and pathological correlation of these two cases are presented. Tumoral calcinosis might be considered as a rare but possible cause of extradural mass. (orig.)

  12. Intracranial tumors in infants: long-term functional outcome, survival, and its predictors.

    Science.gov (United States)

    Pillai, Shibu; Metrie, Mary; Dunham, Christopher; Sargent, Michael; Hukin, Juliette; Steinbok, Paul

    2012-04-01

    Intracranial tumors are rare in the first year of life. This study evaluates survival rates and functional outcomes of survivors at least 5 years after diagnosis and the predictors of this outcome. A retrospective chart review of all infants with a primary intracranial tumor was carried out. Radiology and pathology were re-reviewed. Outcome was assessed at 5 years or more after diagnosis using Bloom's categories (Bloom 1-2 = good outcome, the rest = poor outcome) and late effects severity scoring. Age, tumor location, size, extent of tumor resection, type of adjuvant therapy given, and WHO grade of tumor histology were evaluated as predictors of outcome. Among 35 infants, 20 (57%) survived, with 12 (34%) having a good outcome. Deficits among the survivors included neurological dysfunction in 14 (70%), visual impairment in 9 (45%), endocrine dysfunction in 5 (25%), and auditory disability in 3 (15%). Ten of the 20 survivors were either attending regular school or were engaged in a skilled job. At presentation, older age and an infratentorial location of the tumor are predictors of poor outcome. After histopathological diagnosis, the WHO grading of tumor is the only independent predictor of survival (p = 0.002) and functional outcome (p brain tumors (34%) had a good functional outcome and approximately a quarter of them (28%) were able to attend regular school or take up a skilled job. After tissue diagnosis, histological grade of tumor is the only independent predictor associated with outcome.

  13. Additional value of hybrid SPECT/CT systems in neuroendocrine tumors, adrenal tumors, pheochromocytomas and paragangliomas.

    Science.gov (United States)

    Wong, K K; Chondrogiannis, S; Fuster, D; Ruiz, C; Marzola, M C; Giammarile, F; Colletti, P M; Rubello, D

    The aim of this review was to evaluate the potential advantages of SPECT/CT hybrid imaging in the management of neuroendocrine tumors, adrenal tumors, pheochromocytomas and paragangliomas. From the collected data, the superiority of fused images was observed as providing both functional/molecular and morphological imaging compared to planar imaging. This provided an improvement in diagnostic imaging, with significant advantages as regards: (1) precise locating of the lesions; (2) an improvement in characterization of the findings, resulting higher specificity, improved sensitivity, and overall greater accuracy, (3) additional anatomical information derived from the CT component; (4) CT-based attenuation correction and potential for volumetric dosimetry calculations, and (5) improvement on the impact on patient management (e.g. in better defining treatment plans, in shortening surgical operating times). It can be concluded that SPECT/CT hybrid imaging provides the nuclear medicine physician with a powerful imaging modality in comparison to planar imaging, providing essential information about the location of lesions, and high quality homogeneous images. Copyright © 2016 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  14. MR imaging of the brain: tumors

    International Nuclear Information System (INIS)

    Sartor, K.

    1999-01-01

    The radiologic modality that most likely provides the imaging information needed in a patient suspected of having a brain tumor is MR imaging. A brain tumor can be reliably ruled out if the MR examination is performed properly and experts interpret the results as negative. If there is a tumor, however, its exact location and topography must be determined. Important for therapy and prognosis are also tumor properties such as histologic type and grade, as well as effects on adjacent brain structures. Although potentially a noninvasive method of in vivo neuropathology, MR is still far from being sufficiently specific, as dissimilar lesions may look the same despite the use of refined imaging protocols. The evolution of MR imaging continues, however, making further methodologic improvement likely. Presently, advanced methods, such as diffusion- and perfusion-weighted MR imaging, functional MR imaging, neuronavigation based on MR imaging data, and the use of MR imaging during surgery (intraoperative MR imaging), influence the way patients are treated. Likewise, follow-up imaging (monitoring) of tumor patients by MR has become more effective, and experience has shown how to distinguish reactive changes from recurrent tumor. In the future, MR imaging may gain importance in the development of novel therapeutic concepts. (orig.)

  15. Bone scintigraphic patterns in patients of tumor induced osteomalacia

    International Nuclear Information System (INIS)

    Sood, Ashwani; Agarwal, Kanhaiyalal; Shukla, Jaya; Goel, Reema; Dhir, Varun; Bhattacharya, Anish; Rai Mittal, Bhagwant

    2013-01-01

    Tumor induced osteomalacia (TIO) or oncogenic osteomalacia is a rare condition associated with small tumor that secretes one of the phosphaturic hormones, i.e., fibroblast growth factor 23, resulting in abnormal phosphate metabolism. Patients may present with non-specific symptoms leading to delay in the diagnosis. Extensive skeletal involvement is frequently seen due to delay in the diagnosis and treatment. The small sized tumor and unexpected location make the identification of tumor difficult even after diagnosis of osteogenic osteomalacia. The bone scan done for the skeletal involvement may show the presence of metabolic features and the scan findings are a sensitive indicator of metabolic bone disorders. We present the bone scan findings in three patients diagnosed to have TIO

  16. Relation of external surface to internal tumor motion studied with cine CT

    International Nuclear Information System (INIS)

    Chi, P.-C.M.; Balter, Peter; Luo Dershan; Mohan, Radhe; Pan Tinsu

    2006-01-01

    The accuracy of delivering gated-radiation therapy to lung tumors using an external respiratory surrogate relies on not only interfractional and intrafractional reproducibility, but also a strong correlation between external motion and internal tumor motion. The purpose of this work was to use the cine images acquired by four-dimensional computed tomography acquisition protocol to study the relation between external surface motion and internal tumor motion. The respiratory phase information of tumor motion and chest wall motion was measured on the cine images using a proposed region-of-interest (ROI) method and compared to measurement of an external respiratory monitoring device. On eight lung patient data sets, the phase shifts were measured between (1) the signal of a real-time positioning-management (RPM) respiratory monitoring device placed in the abdominal region and four surface locations on the chest wall (2) the RPM signal in the abdominal region and tumor motions, and (3) chest wall surface motions and tumor motions. Respiratory waveforms measured at different surface locations during the same respiratory cycle often varied and had significant phase shifts. Seven of the 8 patients showed the abdominal motion leading chest wall motion. The best correlation (smallest phase shift) was found between the abdominal motion and the superior-inferior (S-I) tumor motion. A wide range of phase shifts was observed between external surface motion and tumor anterior-posterior (A-P)/lateral motion. The result supported the placement of the RPM block in the abdominal region and suggested that during a gated therapy utilizing the RPM system, it is necessary to place the RPM block at the same location as it is during treatment simulation in order to reduce potential errors introduced by the position of the RPM block. Correlations between external motions and lateral/A-P tumor motions were inconclusive due to a combination of patient selection and the limitation of the ROI

  17. Temperature Measurements of the Low-Attenuation Radiographic Ice Ball During CT-Guided Renal Cryoablation

    International Nuclear Information System (INIS)

    Permpongkosol, Sompol; Link, Richard E.; Kavoussi, Louis R.; Solomon, Stephen B.

    2008-01-01

    During renal cryoablation a low-attenuation area on CT develops around the cryoprobe. Knowledge of the temperature of the growing low-attenuation area can guide therapy and ensure lethal temperatures. Herein, we report thermocouple results and correlating CT images during the development of the low-attenuation 'radiographic ice ball.' Five patients who underwent percutaneous CT-guided renal cryoablation were identified who had thermocouples inserted and serial intraprocedural CT images that included images with thermocouple measurements of 0 o and sub-0 o C. Thermocouples had been percutaneously placed just beyond the edge of the tumors either to ensure adequate cooling or to ensure safety to adjacent critical structures. Renal cryotherapy under CT guidance produced a growing low-attenuation area corresponding to the radiographic ice ball. When the thermocouple measured 0 o C, CT images showed the thermocouple tip at the edge of the low-attenuation ice ball. At lower temperatures the tip was within the low-attenuation ice ball. We conclude that knowledge of the temperature at the ice ball edge during cryoablation can be used to predict the extent of tissue necrosis and thus provide an estimate of cryotherapy effectiveness during the procedure. Further work is necessary to establish a firm relationship between the thermal conditions and the zone of damage

  18. Tumor-Induced Osteomalacia: Increased Level of FGF-23 in a Patient with a Phosphaturic Mesenchymal Tumor at the Tibia Expressing Periostin

    Directory of Open Access Journals (Sweden)

    Anke H. Hautmann

    2014-01-01

    Full Text Available In our case, a 45-year-old male patient had multiple fractures accompanied by hypophosphatemia. FGF-23 levels were significantly increased, and total body magnetic resonance imaging (MRI revealed a tumor mass located at the distal tibia leading to the diagnosis of tumor-induced osteomalacia (TIO. After resection of the tumor, hypophosphatemia and the increased levels of FGF-23 normalized within a few days. Subsequent microscopic examination and immunohistochemical analysis revealed a phosphaturic mesenchymal tumor mixed connective tissue variant (PMTMCT showing a positive expression of somatostatin receptor 2A (SSTR2A, CD68, and Periostin. Electron microscopy demonstrated a poorly differentiated mesenchymal tumor with a multifocal giant cell component and evidence of neurosecretory-granules. However, the resected margins showed no tumor-free tissue, and therefore a subsequent postoperative radiotherapy was performed. The patient is still in complete remission after 34 months. Tumor resection of PMTMCTs is the therapy of choice. Subsequent radiotherapy in case of incompletely resected tumors can be an important option to avoid recurrence or metastasis even though this occurs rarely. The prognostic value of expression of Periostin has to be evaluated more precisely in a larger series of patients with TIO.

  19. Computed tomography (CT) of the parapharyngeal space tumors

    Energy Technology Data Exchange (ETDEWEB)

    Kuriyama, K.; Narumi, Y.; Fujita, M.; Sato, T.; Kajita, A.; Sakai, Y.; Tanaka, H.; Nakanishi, K.; Fujino, Y.

    1987-04-01

    The parapharyngeal space is of great clinical importance. Because of its location deep within the neck, this space is difficult to be examined by ordinary methods but can be well demonstrated by CT. Ten patients with parapharyngeal space tumors were examined with CT. They consisted of 3 pleomorphic adenomas, 1 myoepitherioma, 1 metastatic lymphadenopathy, 1 branchial cleft cyst, 2 schwannomas, 1 neurofibroma and 1 branchiogenic carcinoma respectively. Parapharyngeal space is divided into parapharyngeal space (prestyloid space), carotid space (retrostyloid space), and retropharyngeal space. It is important to determine localization and mapping of parapharyngeal tumors, because the characteristic tumor types in histologic terms are found in each subdivision of parapharyngeal space.

  20. Evaluation of [1-11C]-α-aminoisobutyric acid for tumor detection and amino acid transport measurement: Spontaneous canine tumor studies

    International Nuclear Information System (INIS)

    Bigler, R.E.; Zanzonico, P.B.; Schmall, B.; Conti, P.S.; Dahl, J.R.; Rothman, L.; Sgouros, G.

    1985-01-01

    Alpha-aminoisobutyric acid (AIB) or α-methyl alanine, is a nonmetabolized amino acid treansported into cells particularly malignant cells, predominantly by the ''A'' amino acid transport system. Since it is not metabolized, [1- 11 C]-AIB can be used to quantify A-type amino acid transport into cells using a relatively simple compartmental model and quantitative imaging procedures (e.g. positron tomography). The tissue distribution of [1- 11 C]-AIB was determined in six dogs bearing spontaneous tumors, including lymphosarcoma, osteogenic sarcoma, mammary carcinoma, and adenocarcinoma. Quantitative imaging with tissue radioassay confirmation at necropsy showed poor to excellent tumor localization. However, in all cases the concentrations achieved appear adequate for amino acid transport measurement at known tumor locations. The observed low normal brain (due to blood-brain barrier exclusion) and high (relative to brain) tumor concentrations of [1- 11 C]-AIB suggest that this agent may prove effective for the early detection of human brain tumors. (orig.)

  1. Mortality and Embolic Potential of Cardiac Tumors

    Energy Technology Data Exchange (ETDEWEB)

    Dias, Ricardo Ribeiro, E-mail: ricardo.dias@incor.usp.br; Fernandes, Fábio; Ramires, Félix José Alvarez; Mady, Charles; Albuquerque, Cícero Piva; Jatene, Fábio Biscegli [Instituto do Coração (InCor) do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo, SP (Brazil)

    2014-07-15

    Cardiac tumors are rare, mostly benign with high embolic potential. To correlate the histological type of cardiac masses with their embolic potential, implantation site and long term follow up in patients undergoing surgery. Between January 1986 and December 2011, we retrospectively analyzed 185 consecutive patients who underwent excision of intracardiac mass (119 females, mean age 48±20 years). In 145 patients, the left atrium was the origin site. 72% were asymptomatic and prior embolization was often observed (19.8%). The diagnosis was established by echocardiography, magnetic resonance and histological examination. Most tumors were located in the left side of the heart. Myxoma was the most common (72.6%), followed by fibromas (6.9%), thrombi (6.4%) and sarcomas (6.4%). Ranging from 0.6cm to 15cm (mean 4.6 ± 2.5cm) 37 (19.8%) patients had prior embolization, stroke 10.2%, coronary 4.8%, peripheral 4.3% 5.4% of hospital death, with a predominance of malignant tumors (40% p < 0.0001). The histological type was a predictor of mortality (rhabdomyomas and sarcomas p = 0.002) and embolic event (sarcoma, lipoma and fibroelastoma p = 0.006), but not recurrence. Tumor size, atrial fibrillation, cavity and valve impairment were not associated with the embolic event. During follow-up (mean 80±63 months), there were 2 deaths (1.1%) and two recurrences 1 and 11 years after the operation, to the same cavity. Most tumors were located in the left side of the heart. The histological type was predictor of death and preoperative embolic event, while the implantation site carries no relation with mortality or to embolic event.

  2. Radiofrequency ablation of hepatocellular carcinoma located in the liver dome under intermittent CT fluoroscopy guidance

    Energy Technology Data Exchange (ETDEWEB)

    Park, Darlene; Cho, Yun Ku; Cho, Hyun Je; KIm, Mi Young [Dept. of Radiology, VHS Medical Center, Seoul (Korea, Republic of)

    2014-02-15

    To evaluate the clinical effectiveness of an intermittent computed tomography (CT) fluoroscopy-guided radiofrequency (RF) ablation of hepatocellular carcinoma located in the liver dome. Between 2005 and 2010 23 patients with hepatocellular carcinoma (HCC) nodules located in the liver dome underwent an intermittent CT fluoroscopy-guided RF ablation. The primary endpoint was the local tumor progression. Procedure-related complications occurred in 3 of 23 patients. To evaluate the prognostic factors for the local tumor progression, univariate and multivariate analyses were performed using the Cox proportional hazards model. The chi-squared test was performed to evaluate the association of access route and procedure-related complication. The study was approved by the Institutional Review Board of our hospital. The Tumor sizes ranged between 1.0 and 2.9 cm. An initial complete ablation was achieved in all patients. The median follow-up period was 31 months and the major complication rate was 4.3%. The cumulative rate of local tumor progression at 3 years was 20%. The univariate analysis revealed that only serum total bilirubin level (p = 0.048) and prior chemoembolization were statistically significant (p = 0.044), but there was no independently significant prognostic factor on multivariate analysis. Procedure-related complications occurred in 3 of 23 patients. For HCC located in the liver dome an intermittent CT fluoroscopy-guided RF ablation could be performed safely and effectively.

  3. FDTD analysis of a noninvasive hyperthermia system for brain tumors.

    Science.gov (United States)

    Yacoob, Sulafa M; Hassan, Noha S

    2012-08-14

    Hyperthermia is considered one of the new therapeutic modalities for cancer treatment and is based on the difference in thermal sensitivity between healthy tissues and tumors. During hyperthermia treatment, the temperature of the tumor is raised to 40-45°C for a definite period resulting in the destruction of cancer cells. This paper investigates design, modeling and simulation of a new non-invasive hyperthermia applicator system capable of effectively heating deep seated as well as superficial brain tumors using inexpensive, simple, and easy to fabricate components without harming surrounding healthy brain tissues. The proposed hyperthermia applicator system is composed of an air filled partial half ellipsoidal chamber, a patch antenna, and a head model with an embedded tumor at an arbitrary location. The irradiating antenna is placed at one of the foci of the hyperthermia chamber while the center of the brain tumor is placed at the other focus. The finite difference time domain (FDTD) method is used to compute both the SAR patterns and the temperature distribution in three different head models due to two different patch antennas at a frequency of 915 MHz. The obtained results suggest that by using the proposed noninvasive hyperthermia system it is feasible to achieve sufficient and focused energy deposition and temperature rise to therapeutic values in deep seated as well as superficial brain tumors without harming surrounding healthy tissue. The proposed noninvasive hyperthermia system proved suitable for raising the temperature in tumors embedded in the brain to therapeutic values by carefully selecting the systems components. The operator of the system only needs to place the center of the brain tumor at a pre-specified location and excite the antenna at a single frequency of 915 MHz. Our study may provide a basis for a clinical applicator prototype capable of heating brain tumors.

  4. Does Local Recurrence of Prostate Cancer After Radiation Therapy Occur at the Site of Primary Tumor? Results of a Longitudinal MRI and MRSI Study

    International Nuclear Information System (INIS)

    Arrayeh, Elnasif; Westphalen, Antonio C.; Kurhanewicz, John; Roach, Mack; Jung, Adam J.; Carroll, Peter R.; Coakley, Fergus V.

    2012-01-01

    Purpose: To determine if local recurrence of prostate cancer after radiation therapy occurs at the same site as the primary tumor before treatment, using longitudinal magnetic resonance (MR) imaging and MR spectroscopic imaging to assess dominant tumor location. Methods and Materials: This retrospective study was HIPAA compliant and approved by our Committee on Human Research. We identified all patients in our institutional prostate cancer database (1996 onward) who underwent endorectal MR imaging and MR spectroscopic imaging before radiotherapy for biopsy-proven prostate cancer and again at least 2 years after radiotherapy (n = 124). Two radiologists recorded the presence, location, and size of unequivocal dominant tumor on pre- and postradiotherapy scans. Recurrent tumor was considered to be at the same location as the baseline tumor if at least 50% of the tumor location overlapped. Clinical and biopsy data were collected from all patients. Results: Nine patients had unequivocal dominant tumor on both pre- and postradiotherapy imaging, with mean pre- and postradiotherapy dominant tumor diameters of 1.8 cm (range, 1–2.2) and 1.9 cm (range, 1.4–2.6), respectively. The median follow-up interval was 7.3 years (range, 2.7–10.8). Dominant recurrent tumor was at the same location as dominant baseline tumor in 8 of 9 patients (89%). Conclusions: Local recurrence of prostate cancer after radiation usually occurs at the same site as the dominant primary tumor at baseline, suggesting supplementary focal therapy aimed at enhancing local tumor control would be a rational addition to management.

  5. Rare, but challenging tumors: NET

    International Nuclear Information System (INIS)

    Ivanova, D.; Balev, B.

    2013-01-01

    Full text: Introduction: Gastroenteropancreatic Neuroendocrine Tumors (GEP - NET) are a heterogeneous group of tumors with different locations and many different clinical, histological, and imaging performance. In a part of them a secretion of various organic substances is present. The morbidity of GEP - NET in the EU is growing, and this leads to increase the attention to them. What you will learn: Imaging methods used for localization and staging of GEP - NET, characteristics of the study’s protocols; Classification of GEP - NET; Demonstration of typical and atypical imaging features of GEP - NET in patients registered at the NET Center at University Hospital ‘St. Marina’, Varna; Features of metastatic NET, The role of imaging in the evaluation of treatment response and follow-up of the patients. Discussion: The image semiotics analysis is based on 19 cases of GEP - NET registered NET Center at University Hospital ‘St. Marina’. The main imaging method is multidetector CT (MDCT), and magnetic resonance imaging (MRI ) has advantages in the evaluation of liver lesions and the local prevalence of anorectal tumors. In patients with advanced disease and liver lesions the assessment of skeletal involvement (MRI/ nuclear medical method) is mandatory. The majority of GEP - NET have not any specific imaging findings. Therefore it is extremely important proper planning and conducting of the study (MDCT and MR enterography; accurate assessment phase of scanning, positive and negative contrast). Conclusion: GEP - NET is a major diagnostic challenge due to the absence of typical imaging characteristics and often an overlap with those of the tumors of different origin can be observed. Therefore, a good knowledge of clinical and imaging changes occurring at different locations is needed. MDCT is the basis for the diagnosis, staging and follow-up of these neoplasms

  6. Gastrointestinal Stromal Tumors with Unusual Localization: Report of Three Cases with a Brief Literature Review.

    Science.gov (United States)

    Yucel, Ahmet Fikret; Sunar, Haldun; Hut, Adnan; Kocakusak, Ahmet; Pergel, Ahmet; Barut, Gul; Dikici, Suleyman

    2010-07-26

    The most common tumors derived from the mesenchyme of the gastrointestinal system are stromal tumors. These tumors are typically seen in the stomach and small intestine and less frequently in the colon, rectum and esophagus and are very rarely located outside the gastrointestinal system. Cure is provided with complete surgical resection with resection borders free of tumor. Tumor size, mitotic index, localization, CD117 and CD34 negativity in immunohistochemical studies, mucosal ulceration and presence of necrosis help to predict recurrence of the illness and patient survival. In high-risk gastrointestinal stromal tumors (GISTs) there is an increased rate of recurrence and shortened survival despite complete surgical resection. Thus patients with a high-risk GIST should be given adjuvant therapy with imatinib mesylate. Sunitinib maleate is another FDA-approved agent only for cases who cannot tolerate imatinib or who are resistant to it. Herein we present three cases with GISTs in different locations of the gastrointestinal system with a review of the relevant literature.

  7. Gastrointestinal Stromal Tumors with Unusual Localization: Report of Three Cases with a Brief Literature Review

    Directory of Open Access Journals (Sweden)

    Ahmet Fikret Yucel

    2010-07-01

    Full Text Available The most common tumors derived from the mesenchyme of the gastrointestinal system are stromal tumors. These tumors are typically seen in the stomach and small intestine and less frequently in the colon, rectum and esophagus and are very rarely located outside the gastrointestinal system. Cure is provided with complete surgical resection with resection borders free of tumor. Tumor size, mitotic index, localization, CD117 and CD34 negativity in immunohistochemical studies, mucosal ulceration and presence of necrosis help to predict recurrence of the illness and patient survival. In high-risk gastrointestinal stromal tumors (GISTs there is an increased rate of recurrence and shortened survival despite complete surgical resection. Thus patients with a high-risk GIST should be given adjuvant therapy with imatinib mesylate. Sunitinib maleate is another FDA-approved agent only for cases who cannot tolerate imatinib or who are resistant to it. Herein we present three cases with GISTs in different locations of the gastrointestinal system with a review of the relevant literature.

  8. Tumor Penetrating Theranostic Nanoparticles for Enhancement of Targeted and Image-guided Drug Delivery into Peritoneal Tumors following Intraperitoneal Delivery.

    Science.gov (United States)

    Gao, Ning; Bozeman, Erica N; Qian, Weiping; Wang, Liya; Chen, Hongyu; Lipowska, Malgorzata; Staley, Charles A; Wang, Y Andrew; Mao, Hui; Yang, Lily

    2017-01-01

    The major obstacles in intraperitoneal (i.p.) chemotherapy of peritoneal tumors are fast absorption of drugs into the blood circulation, local and systemic toxicities, inadequate drug penetration into large tumors, and drug resistance. Targeted theranostic nanoparticles offer an opportunity to enhance the efficacy of i.p. therapy by increasing intratumoral drug delivery to overcome resistance, mediating image-guided drug delivery, and reducing systemic toxicity. Herein we report that i.p. delivery of urokinase plasminogen activator receptor (uPAR) targeted magnetic iron oxide nanoparticles (IONPs) led to intratumoral accumulation of 17% of total injected nanoparticles in an orthotopic mouse pancreatic cancer model, which was three-fold higher compared with intravenous delivery. Targeted delivery of near infrared dye labeled IONPs into orthotopic tumors could be detected by non-invasive optical and magnetic resonance imaging. Histological analysis revealed that a high level of uPAR targeted, PEGylated IONPs efficiently penetrated into both the peripheral and central tumor areas in the primary tumor as well as peritoneal metastatic tumor. Improved theranostic IONP delivery into the tumor center was not mediated by nonspecific macrophage uptake and was independent from tumor blood vessel locations. Importantly, i.p. delivery of uPAR targeted theranostic IONPs carrying chemotherapeutics, cisplatin or doxorubicin, significantly inhibited the growth of pancreatic tumors without apparent systemic toxicity. The levels of proliferating tumor cells and tumor vessels in tumors treated with the above theranostic IONPs were also markedly decreased. The detection of strong optical signals in residual tumors following i.p. therapy suggested the feasibility of image-guided surgery to remove drug-resistant tumors. Therefore, our results support the translational development of i.p. delivery of uPAR-targeted theranostic IONPs for image-guided treatment of peritoneal tumors.

  9. Perivascular Epithelioid Cell Tumor in the Stomach

    Directory of Open Access Journals (Sweden)

    Sun Ah Shin

    2017-07-01

    Full Text Available Perivascular epithelioid cell tumors or PEComas can arise in any location in the body. However, a limited number of cases of gastric PEComa have been reported. We present two cases of gastric PEComas. The first case involved a 62-year-old woman who presented with a 4.2 cm gastric subepithelial mass in the prepyloric antrum, and the second case involved a 67-year-old man with a 5.0 cm mass slightly below the gastroesophageal junction. Microscopic examination revealed that both tumors were composed of perivascular epithelioid cells that were immunoreactive for melanocytic and smooth muscle markers. Prior to surgery, the clinical impression of both tumors was gastrointestinal stromal tumor (GIST, and the second case was erroneously diagnosed as GIST even after microscopic examination. Although gastric PEComa is a very rare neoplasm, it should be considered in the differential diagnosis of gastric submucosal lesions.

  10. CT assessment of the correlation between clinical examination and bone involvement in oral malignant tumors

    International Nuclear Information System (INIS)

    Albuquerque, Marco Antonio Portela; Oliveira, Ilka Regina Souza; Cavalcanti, Marcelo Gusmao Paraiso; Kuruoshi, Marcia Etsuko

    2009-01-01

    Oral cancers have a tendency to invade the surrounding bone structures, and this has a direct influence on the treatment management and on outcomes. The objective of this study was to correlate the clinical parameters (location, clinical presentation and TNM staging) of oral malignant tumors that can be associated with a potential of bone invasion and determine the accuracy of clinical examination to predict bone involvement, using computed tomography (CT). Twenty five patients, with oral malignant tumors were submitted to clinical and CT examinations. CT was considered the standard parameter to evaluate the presence of bone involvement. Clinical assessment of location, presentation form and TNM staging of the tumors were then compared to the CT findings in predicting bone involvement. Bone involvement was observed in 68% of the cases. It was predicted that tumors located in the retromolar trigone and hard palate, with a clinical aspect of infiltrative ulcer or nodule and classified in stage IV had a high potential to cause bone involvement. The clinical examination assessment of these tumors showed to be a valuable tool to predict bone invasion, with high sensitivity (82%) and specificity (87.5%), based on the results found in the CT images. No statistical significance was found between the CT and clinical examinations regarding bone involvement. The identification of some clinical parameters such as location, clinical presentation, and TNM stage, associated with a detailed clinical examination, was considered a valuable tool for the assessment of bone destruction by oral malignant tumors. (author)

  11. CT-sialographic evaluation of 19 cases of alivary gland tumors

    Energy Technology Data Exchange (ETDEWEB)

    Yamazaki, Tadashi [Komoro Kousei General Hospital, Nagano (Japan)

    1999-09-01

    Sixteen patients with parotid gland tumors and 3 patients with submandibular gland tumors were evaluated by CT sialography. The 19 patients were 5 to 78 years old, mean age: 57.3 years. CT sialography was performed preoperatively, and postoperative histological examination indicated that the tumors were benign in 13, a cyst in 1, malignant tumors in 4, and a malignant lymphoma in 1 patient. The tumorous lesion detection rate by CT sialography was 100%. The major duct was visualized in all patients, and the examination was informative about the special relationship between the tumor and the facial nerve. No sign of malignancy was noted in an epithelialmyoepithelial carcinoma of 10 mm in diameter on CT sialography. In 2 patients adhesion to surrounding tissues observed intraoperatively was judged to be benign tumors by CT sialography. The marginal morphology of the tumor and the presence or absence of low density areas and punctuate leakage in the interior of the tumor were useful for the judgement of malignancy of salivary gland tumors. CT sialography, which provides diverse information on the location and morphology of the tumor, should be performed early for the diagnosis of salivary gland tumors. (author)

  12. Imitation-tumor targeting based on continuous-wave near-infrared tomography.

    Science.gov (United States)

    Liu, Dan; Liu, Xin; Zhang, Yan; Wang, Qisong; Lu, Jingyang; Sun, Jinwei

    2017-12-01

    Continuous-wave Near-Infrared (NIR) optical spectroscopy has shown great diagnostic capability in the early tumor detection with advantages of low-cost, portable, non-invasive, and non-radiative. In this paper, Modified Lambert-Beer Theory is deployed to address the low-resolution issues of the NIR technique and to design the tumor detecting and imaging system. Considering that tumor tissues have features such as high blood flow and hypoxia, the proposed technique can detect the location, size, and other information of the tumor tissues by comparing the absorbance between pathological and normal tissues. Finally, the tumor tissues can be imaged through tomographic method. The simulation experiments prove that the proposed technique and designed system can efficiently detect the tumor tissues, achieving imaging precision within 1 mm. The work of the paper has shown great potential in the diagnosis of tumor close to body surface.

  13. Antigen localization controls T cell-mediated tumor immunity.

    Science.gov (United States)

    Zeelenberg, Ingrid S; van Maren, Wendy W C; Boissonnas, Alexandre; Van Hout-Kuijer, Maaike A; Den Brok, Martijn H M G M; Wagenaars, Jori A L; van der Schaaf, Alie; Jansen, Eric J R; Amigorena, Sebastian; Théry, Clotilde; Figdor, Carl G; Adema, Gosse J

    2011-08-01

    Effective antitumor immunotherapy requires the identification of suitable target Ags. Interestingly, many of the tumor Ags used in clinical trials are present in preparations of secreted tumor vesicles (exosomes). In this study, we compared T cell responses elicited by murine MCA101 fibrosarcoma tumors expressing a model Ag at different localizations within the tumor cell in association with secreted vesicles (exosomes), as a nonsecreted cell-associated protein, or as secreted soluble protein. Remarkably, we demonstrated that only the tumor-secreting vesicle-bound Ag elicited a strong Ag-specific CD8(+) T cell response, CD4(+) T cell help, Ag-specific Abs, and a decrease in the percentage of immunosuppressive regulatory T cells in the tumor. Moreover, in a therapeutic tumor model of cryoablation, only in tumors secreting vesicle-bound Ag could Ag-specific CD8(+) T cells still be detected up to 16 d after therapy. We concluded that the localization of an Ag within the tumor codetermines whether a robust immunostimulatory response is elicited. In vivo, vesicle-bound Ag clearly skews toward a more immunogenic phenotype, whereas soluble or cell-associated Ag expression cannot prevent or even delay outgrowth and results in tumor tolerance. This may explain why particular immunotherapies based on these vesicle-bound tumor Ags are potentially successful. Therefore, we conclude that this study may have significant implications in the discovery of new tumor Ags suitable for immunotherapy and that their location should be taken into account to ensure a strong antitumor immune response.

  14. Laser fluorescence bronchoscope for localization of occult lung tumors

    International Nuclear Information System (INIS)

    Profio, A.E.; Doiron, D.R.; King, E.G.

    1979-01-01

    A system for imaging occult bronchogenic carcinoma by the fluorescence of previously-injected, tumor-specific compound hematoporphyrin-derivative has been assembled and successfully used to locate a tumor l mm thick. The violet excitation source is a krypton ion laser coupled to fused quartz fiber light conductor. An electrostatic image intensifier attached to a standard flexible fiberoptic bronchoscope provides a bright image even at relatively low irradiance. A red secondary filter rejects most reflected background and autofluorescence. Sensitivity and contrast capability of the system should permit detection of a tumor less than 0.1 mm thick

  15. Podoplanin as Key Player of Tumor Progression and Lymph Vessel Proliferation in Ovarian Cancer.

    Science.gov (United States)

    Cobec, Ionut Marcel; Sas, Ioan; Pirtea, Laurențiu; Cimpean, Anca Maria; Moatar, Aurica Elisabeta; Ceaușu, Raluca Amalia; Raica, Marius

    2016-10-01

    Podoplanin plays a key role in tumor progression and metastasis. We evaluated lymphatics proliferation rate and podoplanin expression in tumor cells of ovarian carcinoma. Seventy-five paraffin-embedded specimens of ovarian cancer were immunohistochemically assessed in order to quantify peritumoral (LMVDP) and intratumoral (LMVDT) lymphatic microvessel density of proliferating lymphatics and for podoplanin variability in tumor cells. LMVDT correlated with proliferating tumor vessels located in the peritumoral area (p=0.024) and with the number of mature vessels located in the intratumoral area (p<0.0001), while LMVDP correlated with peritumoral mature vessels (p<0.000l). Proliferating tumor cells at the invasive front were highly positive for podoplanin. To the best of our knowledge, this study represents the first assessment of lymphatic endothelial cell proliferation correlated with podoplanin expression in tumor cells from ovarian cancer. Our data support podoplanin as a potential target that may help reduce ovarian cancer dissemination and lymphatic metastasis. Copyright© 2016 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  16. Biopsy techniques for intraocular tumors

    Directory of Open Access Journals (Sweden)

    Pukhraj Rishi

    2016-01-01

    Full Text Available Biopsy involves the surgical removal of a tissue specimen for histopathologic evaluation. Most intraocular tumors are reliably diagnosed based on the clinical evaluation or with noninvasive diagnostic techniques. However, accurately diagnosing a small percentage of tumors can be challenging. A tissue biopsy is thus needed to establish a definitive diagnosis and plan the requisite treatment. From fine-needle aspiration biopsy (FNAB to surgical excision, all tissue collection techniques have been studied in the literature. Each technique has its indications and limitations. FNAB has been reported to provide for 88-95% reliable and safe ophthalmic tumor diagnosis and has gained popularity for prognostic purposes and providing eye conserving treatment surgeries. The technique and instrumentation for biopsy vary depending upon the tissue involved (retina, choroid, subretinal space, vitreous, and aqueous, suspected diagnosis, size, location, associated retinal detachment, and clarity of the media. The cytopathologist confers a very important role in diagnosis and their assistance plays a key role in managing and planning the treatment for malignancies.

  17. Accounting for the inertia of the thermocouples' measurements by modelling of a NPP Kalinin-3 transient with the coupled system code ATHLET-BIPR-VVER

    International Nuclear Information System (INIS)

    Nikonov, S.; Velkov, K.

    2008-01-01

    The ATHLET-BIPR-VVER coupled system code is applied for performing of safety analysis for different WWER reactors. During the last years its validation matrix is continuously being enlarged. The measurements performed during the commissioning phase of NPP Kalinin Unit 3 for the transient 'Switching-off of one Main Circulation Pump at nominal power' are very well documented and have a variety of recorded integral and local thermo-hydraulic and neutron-physic parameters including the measurements' errors. This data is being used for further validation of the coupled code system ATHLET-BIPR-VVER. In the paper are discussed the problems and our solutions by the correct interpretation of the measured thermocouples' records at NPP Kalinin-3 and the comparison with the predicted results by the coupled thermal-hydraulic/neutron-kinetic code ATHLET-BIPR-VVER. Of primary importance by such comparisons is the correct accounting of the fluid mixing process that take place in the surrounding of the measuring sensors and also the consideration of the time delay (inertia term) of the measuring devices. On the bases of previous experience and many simulations of the defined transient a method is discussed and proposed to consider correctly the inertia term of the thermocouples' measurements. The new modelling is implemented in the coupled system code ATHLET-BIPR-VVER for further validation. (Author)

  18. MR imaging of benign peripheral nerve sheath tumors

    International Nuclear Information System (INIS)

    Soederlund, V.; Goeranson, H.; Bauer, H.C.F.

    1994-01-01

    In a retrospective, nonblind review of MR imaging of 15 benign peripheral nerve neoplasms in 13 patients, the signal pattern of the tumors (including contrast-enhanced images) and stage were assessed. One lesion was subcutaneous, 9 intramuscular, 2 intermuscular and 3 extracompartmental. One lesion was located to the trunk, 5 to the upper extremity and 9 to the lower. The signal on T1-weighted spin-echo images was homogeneous isointense compared to adjacent muscle in 11 lesions and in 2 slightly hyper- and in 2 slightly hypointense. T2-weighted spin-echo images, acquired in all but one examination, showed a hyperintense signal, homogeneous in 8 and centrally inhomogeneous in 6 lesions. Postcontrast T1-weighted images of 11 lesions, showed a strong signal, with an inhomogeneous enhancement in the center of the lesion similar to that obtained in T2-weighted images. In 2 cases there were signal characteristics indicating bleeding in the tumor. In one lesion both the nonenhanced and contrast-enhanced T1-weighted images showed a hypointense signal in the tumor center suggestive of intramuscular myxoma. All lesions were well delineated without reactive edema. In all cases, anatomic tumor location was correctly assessed. Although the findings were not pathognomonic for neurinoma, MR imaging provided valuable information confirming the clinical and cytologic assessments. (orig.)

  19. CT Findings of Intrarenal Yolk Sac Tumor with Tumor Thrombus Extending into the Inferior Vena Cava: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Shao Chun; Li, Xue Hua; Sun, Can Hui; Feng, Shi Ting; Peng, Zhen Peng; Huang, Si Yun; Li, Zi Ping [Dept. of Radiology, The First Affiliated Hospital, Sun Yat-Sen University, Guangzhou (China)

    2014-10-15

    Yolk sac tumor (YST) is a rare germ cell neoplasm of childhood that usually arises from the testis or ovary. The rare cases of YST in various extragonadal locations have been reported, but the primary intrarenal YST is even more uncommon. Here, we report a case of a primary intrarenal YST with tumor thrombus of the inferior vena cava and left renal vein in a 2-year-old boy, with an emphasis on the CT features. To our knowledge, this is the first reported case of an intrarenal YST with intravascular involvement.

  20. Adnexal Tumors of Skin: An Experience at a Tertiary Care Center at ...

    African Journals Online (AJOL)

    The concordance of clinical and histopathological diagnosis was also assessed. Results: Most of the ATs were benign (24/25) with head and neck being the most common location (72%). Nearly 56% of the tumors exhibited sweat gland differentiation, 28% hair follicle differentiation, and sebaceous gland tumors accounted ...

  1. Atypical size and location of a right atrial myxoma: a case report

    Directory of Open Access Journals (Sweden)

    Nina Vinícius JS

    2012-01-01

    Full Text Available Abstract Introduction Primary intracardiac tumors are rare and approximately 50% are myxomas. The majority of myxomas are located in the left atrium and have variable clinical presentation. We report a case of a large myxoma in the right atrium, which is an uncommon location for this type of tumor. Case presentation A 45-year-old Caucasian woman with a history of palpitation had dyspnea on great exertion and discrete weight loss. A cardiac evaluation showed splitting of S1. An echocardiogram showed a large mass in the right atrium, suggesting myxoma; chest computed tomography confirmed the diagnostic hypothesis. Our patient underwent surgical treatment with excision of a 10 cm multilobulated mass. She presented with supraventricular tachycardia during the operation. She was placed in the intensive care unit and her condition improved after the use of amiodarone. The diagnosis of myxoma was confirmed by histopathological study. Conclusions In this case report, we emphasize the rarity of large myxomas in the right atrium and the difficulty of differential diagnosis given their dimension and location.

  2. Effect and toxicity of endoluminal high-dose-rate (HDR) brachytherapy in centrally located tumors of the upper respiratory tract

    International Nuclear Information System (INIS)

    Harms, W.; Wannenmacher, M.; Becker, H.; Herth, F.; Fritz, P.

    2000-01-01

    Aim: To assess effect an toxicity of high-dose-rate afterloading (HDR) alone or in combination with external beam radiotherapy (EBRT) in centrally located tumors of the upper respiratory tract. Patients and Methods: From 1987 to 1996, 55 patients were treated. Twenty-one patients (group A1: 17 non-small-cell lung cancer [NSCLC], A2: 4 metastases from other malignancies) were treated using HDR alone due to a relapse after external beam irradiation. In 34 previously untreated and inoperable patients (group B1: 27 NSCLC, B2: 7 metastases from other malignancies) HDR was given as a boost after EBRT (30 to 60 Gy, median 50). HDR was carried out with a 192 Ir source (370 GBq). The brachytherapy dose (group A: 5 to 27 Gy, median 20; B: 10 to 20 Gy, median 15) was prescribed to 1 cm distance from the source axis. A distanciable applicator was used in 39/55 patients. Results: In group A1, a response rate (CR, PR) of 53% (group B1: 77%) was reached. The median survival (Kaplan-Meier) was 5 months in group A1 (B1: 20 months). The 1-, 3- and 5-year local progression free survival rates (Kaplan-Meier) were 66% (15%), 52% (0%), and 37% (0%) in group B1 (group A1). Prognostic favorable factors in group B1 were a tumor diameter 70. Grade-1 or 2 toxicity (RTOG/EORTC) occurred in 0% in group A and in 6% in group B. We observed no Grad-3 or 4 toxicity. Complications caused by persistent or progressive local disease occurred in 3 patients in goup A (fatal hemorrhage, tracheomediastinal fistula, hemoptysis) and in 2 patients in group B (fatal hemorrhage, hemoptysis). Conclusions: HDR brachytherapy is an effective treatment with moderate side effects. In combination with external beam irradiation long-term remissions can be reached in one third of the patients. (orig.) [de

  3. Gamma thermometer longevity test: Laguna Verde 2 instruments recent performance

    International Nuclear Information System (INIS)

    Cuevas V, G.; Avila N, A.; Calleros M, G.

    2013-10-01

    This paper is informative of the General Electric Hitachi and Global Nuclear Fuel - Americas are collaboration with Comision Federal de Electricidad in a longevity test of thermocouples as power monitoring devices. The test conclusions will serve for final engineering design in detailing the Automated Fixed In-core Probes for calibration of the Local Power Range Monitors (LPRMs) of the Economic Simplified Boiling Water Reactor. This paper introduces the collaboration description and some recent performance evaluation of the thermocouples that are sensitive to gamma radiation and are known generically as Gamma Thermometers (G T). The G Ts in Laguna Verde 2 are radially located inside six instrumentation tubes in the core and consist of seven thermocouples, four are aligned with the LPRM heights and three are axially located between LPRM heights. The Laguna Verde 2 G T test has become the longest test of thermocouples as power monitoring devices in a BWR industry history and confirms their reliability in terms of time-dependent small noise under steady state reactor conditions and good agreement against Traversing In-core Probes power measurements. (Author)

  4. Gamma thermometer longevity test: Laguna Verde 2 instruments recent performance

    Energy Technology Data Exchange (ETDEWEB)

    Cuevas V, G. [Global Nuclear Fuel, Americas, 3901 Castle Hayne Road, Wilmington, North Carolina (United States); Avila N, A.; Calleros M, G., E-mail: Gabriel.Cuevas-Vivas@gnf.com [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verda, Carretera Veracruz-Nautla Km 42.5, Alto Lucero, Veracruz (Mexico)

    2013-10-15

    This paper is informative of the General Electric Hitachi and Global Nuclear Fuel - Americas are collaboration with Comision Federal de Electricidad in a longevity test of thermocouples as power monitoring devices. The test conclusions will serve for final engineering design in detailing the Automated Fixed In-core Probes for calibration of the Local Power Range Monitors (LPRMs) of the Economic Simplified Boiling Water Reactor. This paper introduces the collaboration description and some recent performance evaluation of the thermocouples that are sensitive to gamma radiation and are known generically as Gamma Thermometers (G T). The G Ts in Laguna Verde 2 are radially located inside six instrumentation tubes in the core and consist of seven thermocouples, four are aligned with the LPRM heights and three are axially located between LPRM heights. The Laguna Verde 2 G T test has become the longest test of thermocouples as power monitoring devices in a BWR industry history and confirms their reliability in terms of time-dependent small noise under steady state reactor conditions and good agreement against Traversing In-core Probes power measurements. (Author)

  5. A method of surface marker location optimization for tumor motion estimation in lung stereotactic body radiation therapy

    International Nuclear Information System (INIS)

    Lu, Bo; Park, Justin C.; Fan, Qiyong; Kahler, Darren; Liu, Chihray; Chen, Yunmei

    2015-01-01

    Purpose: Accurately localizing lung tumor localization is essential for high-precision radiation therapy techniques such as stereotactic body radiation therapy (SBRT). Since direct monitoring of tumor motion is not always achievable due to the limitation of imaging modalities for treatment guidance, placement of fiducial markers on the patient’s body surface to act as a surrogate for tumor position prediction is a practical alternative for tracking lung tumor motion during SBRT treatments. In this work, the authors propose an innovative and robust model to solve the multimarker position optimization problem. The model is able to overcome the major drawbacks of the sparse optimization approach (SOA) model. Methods: The principle-component-analysis (PCA) method was employed as the framework to build the authors’ statistical prediction model. The method can be divided into two stages. The first stage is to build the surrogate tumor matrix and calculate its eigenvalues and associated eigenvectors. The second stage is to determine the “best represented” columns of the eigenvector matrix obtained from stage one and subsequently acquire the optimal marker positions as well as numbers. Using 4-dimensional CT (4DCT) and breath hold CT imaging data, the PCA method was compared to the SOA method with respect to calculation time, average prediction accuracy, prediction stability, noise resistance, marker position consistency, and marker distribution. Results: The PCA and SOA methods which were both tested were on all 11 patients for a total of 130 cases including 4DCT and breath-hold CT scenarios. The maximum calculation time for the PCA method was less than 1 s with 64 752 surface points, whereas the average calculation time for the SOA method was over 12 min with 400 surface points. Overall, the tumor center position prediction errors were comparable between the two methods, and all were less than 1.5 mm. However, for the extreme scenarios (breath hold), the

  6. Thermocouple and Infrared Sensor-Based Measurement of Temperature Distribution in Metal Cutting

    Directory of Open Access Journals (Sweden)

    Abdil Kus

    2015-01-01

    Full Text Available In metal cutting, the magnitude of the temperature at the tool-chip interface is a function of the cutting parameters. This temperature directly affects production; therefore, increased research on the role of cutting temperatures can lead to improved machining operations. In this study, tool temperature was estimated by simultaneous temperature measurement employing both a K-type thermocouple and an infrared radiation (IR pyrometer to measure the tool-chip interface temperature. Due to the complexity of the machining processes, the integration of different measuring techniques was necessary in order to obtain consistent temperature data. The thermal analysis results were compared via the ANSYS finite element method. Experiments were carried out in dry machining using workpiece material of AISI 4140 alloy steel that was heat treated by an induction process to a hardness of 50 HRC. A PVD TiAlN-TiN-coated WNVG 080404-IC907 carbide insert was used during the turning process. The results showed that with increasing cutting speed, feed rate and depth of cut, the tool temperature increased; the cutting speed was found to be the most effective parameter in assessing the temperature rise. The heat distribution of the cutting tool, tool-chip interface and workpiece provided effective and useful data for the optimization of selected cutting parameters during orthogonal machining.

  7. Thermocouple and Infrared Sensor-Based Measurement of Temperature Distribution in Metal Cutting

    Science.gov (United States)

    Kus, Abdil; Isik, Yahya; Cakir, M. Cemal; Coşkun, Salih; Özdemir, Kadir

    2015-01-01

    In metal cutting, the magnitude of the temperature at the tool-chip interface is a function of the cutting parameters. This temperature directly affects production; therefore, increased research on the role of cutting temperatures can lead to improved machining operations. In this study, tool temperature was estimated by simultaneous temperature measurement employing both a K-type thermocouple and an infrared radiation (IR) pyrometer to measure the tool-chip interface temperature. Due to the complexity of the machining processes, the integration of different measuring techniques was necessary in order to obtain consistent temperature data. The thermal analysis results were compared via the ANSYS finite element method. Experiments were carried out in dry machining using workpiece material of AISI 4140 alloy steel that was heat treated by an induction process to a hardness of 50 HRC. A PVD TiAlN-TiN-coated WNVG 080404-IC907 carbide insert was used during the turning process. The results showed that with increasing cutting speed, feed rate and depth of cut, the tool temperature increased; the cutting speed was found to be the most effective parameter in assessing the temperature rise. The heat distribution of the cutting tool, tool-chip interface and workpiece provided effective and useful data for the optimization of selected cutting parameters during orthogonal machining. PMID:25587976

  8. Estudio sobre los tumores malignos maxilofaciales

    Directory of Open Access Journals (Sweden)

    Juan Carlos Quintana Díaz

    1998-08-01

    Full Text Available Se realizó un análisis durante el trienio 1994-1996 y se estudiaron los tumores malignos de la región maxilofacial tratados en el Servicio de Cirugía Maxilofacial de Artemisa. El sexo masculino fue más afectado que el femenino, los tumores de la piel fueron los más frecuentes, afectaron en elevado porcentaje a los pacientes de tez blanca, y el carcinoma basocelular fue el tipo histológico que más se observó. En cuanto a la localización más frecuente en la cavidad bucal fue el labio inferior, y el tipo histológico que más predominó fue el carcinoma epidermoide. El 3 % de todos los tumores encontrados correspondieron con metástasis, que debutaron por la zona bucofacial.An analytical study of the maxillofacial region malignant tumors treated in the Maxillofacial Surgery Service of Artemisa municipality was conducted from 1994-1996. Males were the most affected; skin tumors were the most frequent, a higher percentage of white people were affected and the most observed histological type was the basal cell carcinoma. The most common location in the oral cavity was the lower lip and the most predominant histological type was the epidermoid carcinoma. 3 % of all tumors found resulted in metastasis which started in the buccofacial area.

  9. Melanotic neuroectodermal primitive tumor of infancy. Report of a case

    International Nuclear Information System (INIS)

    Suarez Mattos, Amaranto; Restrepo, Ligia; Penagos, Pedro; Rubio, Alba

    2002-01-01

    The melanotic neuroectodermal tumor of infancy is a rare neoplasia originated from the neural crest, it is frequently located in orofacial bones, although other localizations have been reported; occurs predominantly in infants. The behavior is benign and the treatment consists mainly in complete surgical resection. A four-month old male with an orbital tumor and intracranial extension, managed surgically with favorable outcome, is described

  10. Keratocystic odontogenic tumor

    Directory of Open Access Journals (Sweden)

    BRENDA DE SOUZA MOURA

    Full Text Available ABSTRACT Objective: to evaluate the frequency of keratocystic odontogenic tumor (KOT in the Oral Surgery Service (OSS of the University Hospital Clementino Fraga Filho of the Federal University of Rio de Janeiro (HUCFF / UFRJ, with respect to recurrence rate, gender, age of recurrence and location of the injury Methods: clinical records were reviewed and histopathological reports of KOT patients of the HUCFF/UFRJ between 2002 and 2012. Patients diagnosed with KOT were divided into two groups for the occurrence of relapse: positive (n=6 and negative (n=19 Results: regarding the location, there was a predilection for the mandible. In the average age of patients in the positive group was 40.5 and the negative group, 35.53. In the distribution by gender, positive group showed equal distribution, different from that observed in the negative group, which showed a predilection for males Conclusion: KOT was the second most frequent injury in our patients, recurrence was lower among males and had the jaw as most affected location

  11. Radiological and histopathological study of benign tumors of the mandible

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Seon Young; Baek, Seung Yon; Choi, Kyung Hee; Suh, Jeung Soo; Rhee, Chung Sik; Kim, Hee Seup [Ewha Womans University College of Medicine, Seoul (Korea, Republic of)

    1984-06-15

    Benign tumors of the mandible are uncommon lesions. That were classified into odontogenic tumors and nonodontogenic tumors. Author reviewed the radiological evaluation and pathological microscopic finding from 33 benign tumors of the mandible that were confirmed by the biopsy during last 10 years in Dental Clinics, Ewha Womans University Hospital and Seoul National University Dental Hospital. Following results were obtained; 1. Benign tumors of the mandible were classified into odontogenic (66.7%) and non-odontogenic tumors (33.3%). 2. The range of the age distribution was between 6 years and 67 years old. The commonest age group was the second decade (39.4%). 3. There was no difference to sex distribution. 4. The most frequent location was the body of the mandible (42.4%). 5. Radiographic findings were relatively characteristic in odontogenic tumors rather than non-odontogenic tumors. 1) Radiolucent cystic lesions-ameloblastoma, odontogenic myxoma, odontogenic fibtoma, aneurysmal bone cyst and neurofibroma. 2) Radiopaque mass lesions-odontoma, cementoma and osteoma. 3) Mixed patterns-ossifying fibroma, cementifying fibroma, calcifying odontogenic epithelial tumor and hemangioma. It was concluded that the radiographic examination was of value to diagnose the benign tumors of the mandible in symptomless patients.

  12. Malignant primary germ-cell tumor of the brain: case report

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Toyoshiro; Sato, Shinichi; Nakao, Satoshi; Ban, Sadahiko; Namba, Koh (Kobe Municipal Central Hospital (Japan))

    1983-04-01

    The unusual case of a 15 year old boy with three discrete paraventricular germ-cell tumors is reported. The first tumor was located just lateral to the left thalamus and included a massive cystic part around it, the second tumor in the paraventricular region above the head of the left caudate nucleus and the third tumor in the medial part of the left parietal lobe. Total removal of all tumors was successfully accomplished in stages at four separate operations, namely, the first tumor was removed through the left transsylvian approach, the second tumor via left superior frontal gyrus and the third tumor via left superior frontal gyrus and left superior parietal lobule. Histological examination revealed that the first tumor was teratoma, the second was choriocarcinoma and the third was germinoma. Primary germ-cell tumors of the brain can be divided into 5 groups: 1) germinoma; 2) embryonal carcinoma; 3) choriocarcinoma; 4) yolk-sac tumor; or 5) teratoma. In this case, a combination of three different histological patterns was seen. If malignant germ-cell tumor is supected on CT, aggressive extirpation should be done, not only to determine the exact diagnosis, but also to provide the basis for subsequent adjunctive therapy.

  13. Pheochromocytoma and gastrointestinal stromal tumors in patients with neurofibromatosis type I.

    Science.gov (United States)

    Vlenterie, Myrella; Flucke, Uta; Hofbauer, Lorenz C; Timmers, Henri J L M; Gastmeier, Joerg; Aust, Daniela E; van der Graaf, Winette T A; Wesseling, Pieter; Eisenhofer, Graeme; Lenders, Jacques W M

    2013-02-01

    Neurofibromatosis I may rarely predispose to pheochromocytoma and gastrointestinal stromal tumors. A 59-year-old woman with neurofibromatosis I presented with pheochromocytoma of the left adrenal gland. During surgery, 3 gastrointestinal stromal tumors adjacent to the stomach and small intestine were removed. Despite appropriate thrombosis prophylaxis, the patient died of a pulmonary embolus 2 days postoperatively. The second patient, a 55-year-old man with neurofibromatosis I and bilateral pheochromocytomas, had several small gastrointestinal stromal tumors adjacent to the jejunum during surgery. A review of the literature was conducted to identify patients with neurofibromatosis I with concurrence of pheochromocytoma and gastrointestinal stromal tumors and to define the specific clinical features of these patients. In addition to our 2 patients, 12 other cases of neurofibromatosis I with concomitant occurrence of pheochromocytomas and gastrointestinal stromal tumors have been reported. Pheochromocytomas had adrenal locations in all patients. Two of the 14 patients had a mixed pheochromocytoma/ganglioneuroma. In 4 of the 14 patients, gastrointestinal stromal tumors were located along the stomach. The gastrointestinal stromal tumors in our 2 patients showed no somatic mutations in KIT and PDGFRA genes. A pulmonary embolism was diagnosed in 4 patients. The simultaneous occurrence of pheochromocytoma and gastrointestinal stromal tumor should be considered in all patients with neurofibromatosis I presenting with an abdominal mass with symptoms suggestive of pheochromocytoma. Therefore, a pheochromocytoma should be excluded before a patient with neurofibromatosis I undergoes surgery for a gastrointestinal stromal tumor because an undiagnosed pheochromocytoma carries a high risk of life-threatening cardiovascular complications during surgery. Finally, this combination may be associated with an increased risk for thromboembolic events, but more studies are necessary to

  14. Giant cell tumor in long bones: the significance of marginal sclerosis for the differential diagnosis

    International Nuclear Information System (INIS)

    Kim, Hee Jin; Suh, Jin Suck; Park, Chang Yun

    1993-01-01

    Plain radiographs of thirty nine patients with giant cell tumor of long bone and CT scans of twenty patients among the thirty patients were reviewed retrospectively to evaluate the frequency and significance of sclerosis of the tumor margin. The sclerosis of the tumor margin was observed on plain radiographs in thirteen patients(33.3%) and they were located either on epiphyseal or on both epiphyseal or metaphyseal portion of the tumor. The authors concluded that the giant cell tumor should not be excluded from the differential entities even though the tumor has the marginal sclerosis

  15. Cellular Angiofibroma of the Prostate: A Rare Tumor in an Unusual Location

    Directory of Open Access Journals (Sweden)

    Inez Wyn

    2014-01-01

    Full Text Available We report the unusual occurrence of a cellular angiofibroma in prostatic tissue. In this case, a 84-year-old man presented in the emergency room with urinary retention. Ultrasound revealed an enlarged prostate, which was suggestive for benign prostatic hyperplasia. The patient was treated with a Millin retropubic prostatectomy. Macroscopically the prostate contained multiple circumscribed nodules. Microscopic examination of the tumor showed the appearance of cellular angiofibroma, consisting of bland spindle cells and prominent, hyalinized vessels. The diagnosis was supported by FISH, which revealed monoallelic loss of RB1/13q14 region, as seen in spindle cell lipoma, (extra- mammary myofibroblastoma, and cellular angiofibroma. Cellular angiofibromas are rare, benign soft tissue tumours and were never reported in the prostatic gland.

  16. Esophageal Endosonography for the Diagnosis of Intrapulmonary Tumors

    DEFF Research Database (Denmark)

    Korevaar, Daniël A; Colella, Sara; Spijker, René

    2017-01-01

    BACKGROUND: Biopsy-based diagnosis in patients with paraesophageal intrapulmonary tumors suspected of lung cancer is crucial for adequate treatment planning. OBJECTIVE: To evaluate the performance of transesophageal endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) in the diagnosis...... of intrapulmonary tumors located near or adjacent to the esophagus. METHODS: We performed a systematic review (PROSPERO, CRD42016033737) and searched MEDLINE, Embase, BIOSIS Previews, and Web of Science on September 22, 2016, without date or language restrictions. We included studies that evaluated the yield and...

  17. A preliminary survey of central nervous system tumors in Tema, Ghana.

    Science.gov (United States)

    Andrews, N B; Ramesh, R; Odjidja, T

    2003-06-01

    In January 2000, the first ever neurosurgical program in Tema was established. This preliminary survey was conducted for the following purposes. 1) to determine the relative frequencies of the various histopathological types of CNS tumors. 2) To relate the occurrence of the various types of CNS tumors to age, sex, symptoms, neurologic findings and location. 3) to review the current use of neurodiagnostic modalities. A retrospective analysis of the records of 30 consecutive patients seen at T. I. N. with histologically proven CNS tumors was carried out. The following parameters were analysed; sex, age, symptoms, neurologic status, surgical procedure, histopathological diagnosis, pre and post operative Karnofsky rating. 30 patients (14M, 16F) constituted the series. Their mean age was 39.8 (R 2-72, SD, 18.7) years. The difference between the mean ages of patients with intracranial or spinal tumors was not significant (P>0.05). For intracranial tumors, there was a significant difference between the mean ages of those with infratentorial and supratentorial tumors. Spinal tumors constituted 13% of the series and they all presented with paraplegia. Eighty seven percent had intracranial tumors; of these 27% presented with headaches and 31% with seizures. Only 62% of patients with intracranial tumors presented with neurologic deficits. CT scanning was the diagnostic modality utilized in the diagnosis of all the intracranial tumors. Cerebral angiography was not obtained in any case. Myelography and post myelography CT scanning diagnosed all spinal tumors. Surgical procedures for CNS tumors constituted 23% of all neurosurgical surgical procedures performed during the study period. All patients with spinal tumors underwent laminectomy only. Sixty five percent of those with intracranial tumors underwent craniotomy; 34% underwent stereotactic biopsy. The most common intracranial tumor was high-grade astrocytoma (HGA), 23%. The left frontal lobe was the most common location of

  18. Granular cells Tumor in the gastrointestinal tract

    International Nuclear Information System (INIS)

    Castano LL, Rodrigo; Gaitan B, Maria H; Juliao E, Fabian

    2005-01-01

    Granular cells tumors are ubiquitous lesions in the gastrointestinal tract, are rare and asymptomatic and they are generally an incidental discovery at gastroduodenoscopy or colonoscopy. In the gastrointestinal tract they are more frequently located in the esophagus, right colon and rectum, stomach, appendix, small intestine or biliopancreatic tract. This article describes three patients with four tumors of granular cells in rectum, esophagus (2 lesions) and appendix. It becomes special emphasis in their neural origin, their benign behavior that justifies the endoscopic resections or limited surgical excisions and the necessity of a pursuit for the possibility, although little, of malignant transformation

  19. CT-criteria of orbital hemangiomas and their importance in differential diagnosis of intraconal tumors

    Energy Technology Data Exchange (ETDEWEB)

    Unsoeld, R; Hoyt, W F [California Univ., San Francisco (USA). Dept. of Neurosurgery; California Univ., San Francisco (USA). Dept. of Neurology and Opthalmology; California Univ., San Francisco (USA). Dept. of Neuroradiology)

    1979-12-01

    CT-Scans of 29 histologically proven cavernous hemangiomas were evaluated with respect to their location, shape, delineation from surrounding tissue, contrast-enhancement, and secondary changes of the bony orbit. Whenever a round or oval tumor, located in the outer upper muscle cone, sharply delineated from surrounding tissue, unattached to optic nerve and ocular muscles, spares a small triangular space in the orbital apex, it is in all probability a cavernous hemangioma. Evaluation of the tumors shape and its separation from surrounding tissues requires imaging in multiple sections in two planes oriented, if possible, at right angles. Changes in position of the optic nerve and eye muscles in different directions of gaze demonstrated by CT rule out significant tumor-attachments. The portion of the intraconal space least affected by optic nerve shifts and muscle contractions during eye movements, as demonstrated by CT, is the upper outer quadrant, the site preferred by the mobile tumor. Tumors which cannot be differentiated from cavernous hemangiomas by CT-criteria are rare usually benign. Reports of rare examples of well delineated or encapsulated malignant intraconal lesions indicate the possibility - however remote - of mistaking a malignant tumor for a cavernous hemangioma by CT.

  20. CT findings of the mediastinal tumors -excluding mediastinal granuloma and primary carcinoma-

    International Nuclear Information System (INIS)

    Lee, Kyung Soo; Im, Chung Kie; Han, Man Chung

    1985-01-01

    Computerized Tomography can make accurate diagnosis in most of the mediastinal tumors and cysts by assessing their location, shape and internal architecture. Authors analysed and present CT findings of 89 surgically proven mediastinal tumors and cysts that were studied and treated in Seoul National University Hospital during recent 5 years. The results are as follows; 1. The most common tumor was teratoma (25 cases). Neurogenic tumor (20 cases), thymic tumor or cyst (16 cases), lymphoma (7 cases), bronchogenic cyst (6 cases), intrathoracic goiter (6 cases), pericardial cyst (3 cases) and cystic hygroma (2 cases) were next in order of frequency. 2. The most constant findings of teratoma was thick walled cystic area (100%), while pathognomonic fat and calcified density were seen only in 52% and 48% of cases, respectively. 22 cases were located in anterior mediastinum, 2 cases were in posterior mediastinum and a case is in middle mediastinum. 3. There were 20 cases of neurogenic tumor consisting of 6 neurilemmomas, 7 ganglioneuromas, 4 neurofibromas, 1 ganglioneuroblastoma, 1 neuroblastoma and 1 malignant schwannoma. Most of them were located in posterior mediastinum with exception of 2 neurilemmomas arising from left vagus nerve and left recurrent laryngeal nerve in middle mediastinum. Cystic change was seen in 2 cases of neurilemmoma and in a case of ganglioneuroma. Calcification was seen in 3 cases, of neuroblastoma, a neurilemmoma, and a ganglioneuroma. 4. There were 11 cases of thymoma showing homogeneous solid mass with speckeld calcification in 4 cases and irregular cystic change in 3 cases. 2 cases were invasive thymoma and myasthenia gravis was present in 4 cases. A cases of thymolipoma and a case of thymic cyst were included. 5. Lymphoma (2 Hodgkin's and 4 non-Hodgkin's) appeared as lobulated, matted mass in anterior mediastinum especially in prevascular area expanding bilaterally

  1. CT findings of the mediastinal tumors -excluding mediastinal granuloma and primary carcinoma-

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Soo; Im, Chung Kie; Han, Man Chung [College of Medicine, Seoul National University, Seoul (Korea, Republic of)

    1985-06-15

    Computerized Tomography can make accurate diagnosis in most of the mediastinal tumors and cysts by assessing their location, shape and internal architecture. Authors analysed and present CT findings of 89 surgically proven mediastinal tumors and cysts that were studied and treated in Seoul National University Hospital during recent 5 years. The results are as follows; 1. The most common tumor was teratoma (25 cases). Neurogenic tumor (20 cases), thymic tumor or cyst (16 cases), lymphoma (7 cases), bronchogenic cyst (6 cases), intrathoracic goiter (6 cases), pericardial cyst (3 cases) and cystic hygroma (2 cases) were next in order of frequency. 2. The most constant findings of teratoma was thick walled cystic area (100%), while pathognomonic fat and calcified density were seen only in 52% and 48% of cases, respectively. 22 cases were located in anterior mediastinum, 2 cases were in posterior mediastinum and a case is in middle mediastinum. 3. There were 20 cases of neurogenic tumor consisting of 6 neurilemmomas, 7 ganglioneuromas, 4 neurofibromas, 1 ganglioneuroblastoma, 1 neuroblastoma and 1 malignant schwannoma. Most of them were located in posterior mediastinum with exception of 2 neurilemmomas arising from left vagus nerve and left recurrent laryngeal nerve in middle mediastinum. Cystic change was seen in 2 cases of neurilemmoma and in a case of ganglioneuroma. Calcification was seen in 3 cases, of neuroblastoma, a neurilemmoma, and a ganglioneuroma. 4. There were 11 cases of thymoma showing homogeneous solid mass with speckeld calcification in 4 cases and irregular cystic change in 3 cases. 2 cases were invasive thymoma and myasthenia gravis was present in 4 cases. A cases of thymolipoma and a case of thymic cyst were included. 5. Lymphoma (2 Hodgkin's and 4 non-Hodgkin's) appeared as lobulated, matted mass in anterior mediastinum especially in prevascular area expanding bilaterally.

  2. Origins of feeding arteries of hepatocellular carcinoma located near the umbilical fissure of the left hepatic lobe: angiographic evaluation.

    Science.gov (United States)

    Miyayama, Shiro; Yamashiro, Masashi; Shibata, Yoshihiro; Hashimoto, Masahiro; Yoshida, Miki; Tsuji, Kazunobu; Toshima, Fumihito; Matsui, Osamu

    2012-12-01

    To analyze the origins of the feeding arteries of hepatocellular carcinomas (HCCs) near the umbilical fissure of the left hepatic lobe. Twenty-eight HCCs with a mean ± SD tumor diameter of 3.4 ± 1.0 cm (range 1-4.4 cm) in contact with the right or left side of the umbilical fissure were treated by superselective transcatheter arterial chemoembolization (TACE). The origins of the tumor-feeding arteries were analyzed with arteriograms and computed tomography or cone-beam computed tomography images obtained during and 1 week after TACE. Twenty-one HCC lesions were located in segment 3 and seven were located in segment 4. Of 21 tumors in segment 3, 13 (61.9%) were supplied by the lateral inferior subsegmental artery (A3), three (14.3%) by the medial subsegmental artery (A4), three (14.3%) by both A4 and A3, one (4.8%) by a branch arising from the left lateral hepatic artery, and one (4.8%) by a branch of the right gastric artery. In particular, all tumor-feeding branches arising from A4 were the first branch of A4. Of seven tumors in segment 4, four (57.1%) were supplied by A4 and three (42.9%) by A3. In particular, all tumor-feeding branches arising from A3 were the first branch of A3. This study demonstrates crossover blood supply to HCC lesions located near the umbilical fissure, in addition to direct feeding from a separate branch. In particular, the first branch of the opposite subsegmental artery may feed tumors when crossover blood supply is present.

  3. Origins of Feeding Arteries of Hepatocellular Carcinoma Located Near the Umbilical Fissure of the Left Hepatic Lobe: Angiographic Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Miyayama, Shiro, E-mail: s-miyayama@fukui.saiseikai.or.jp; Yamashiro, Masashi; Shibata, Yoshihiro; Hashimoto, Masahiro; Yoshida, Miki; Tsuji, Kazunobu; Toshima, Fumihito [Fukuiken Saiseikai Hospital, Department of Diagnostic Radiology (Japan); Matsui, Osamu [Kanazawa University Graduate School of Medical Science, Department of Radiology (Japan)

    2012-12-15

    Purpose: To analyze the origins of the feeding arteries of hepatocellular carcinomas (HCCs) near the umbilical fissure of the left hepatic lobe. Methods: Twenty-eight HCCs with a mean {+-} SD tumor diameter of 3.4 {+-} 1.0 cm (range 1-4.4 cm) in contact with the right or left side of the umbilical fissure were treated by superselective transcatheter arterial chemoembolization (TACE). The origins of the tumor-feeding arteries were analyzed with arteriograms and computed tomography or cone-beam computed tomography images obtained during and 1 week after TACE.ResultsTwenty-one HCC lesions were located in segment 3 and seven were located in segment 4. Of 21 tumors in segment 3, 13 (61.9%) were supplied by the lateral inferior subsegmental artery (A3), three (14.3%) by the medial subsegmental artery (A4), three (14.3%) by both A4 and A3, one (4.8%) by a branch arising from the left lateral hepatic artery, and one (4.8%) by a branch of the right gastric artery. In particular, all tumor-feeding branches arising from A4 were the first branch of A4. Of seven tumors in segment 4, four (57.1%) were supplied by A4 and three (42.9%) by A3. In particular, all tumor-feeding branches arising from A3 were the first branch of A3. Conclusion: This study demonstrates crossover blood supply to HCC lesions located near the umbilical fissure, in addition to direct feeding from a separate branch. In particular, the first branch of the opposite subsegmental artery may feed tumors when crossover blood supply is present.

  4. Lack of correlation between the location of choroidal melanoma and ultraviolet radiation dose distribution

    International Nuclear Information System (INIS)

    Schwartz, L.; Ferrand, R.; Boelle, P.Y.; Maylin, C.; D'Hermies, F.; Virmont, J.

    1998-01-01

    Full text of publication follows: ocular melanomas arise from the choroid. The result of our study of a total of 92 ocular melanomas would indicate that there is no preferential location for tumors on the eye. We estimate the ultraviolet (UV) radiation dose distribution using data available in the literature. We then compared tumor location and UV radiation. UVC and UVB do not reach the choroid and UVA is filtered by the cornea and the lens. Only, a small percentage of the incoming rays reach the posterior and inferior part of retina, but none reach the superior and anterior part of the eye. We concluded that it is therefore very unlikely that UV radiation exposure is responsible for choroidal melanoma. (authors)

  5. FDTD analysis of a noninvasive hyperthermia system for brain tumors

    Directory of Open Access Journals (Sweden)

    Yacoob Sulafa M

    2012-08-01

    Full Text Available Abstract Background Hyperthermia is considered one of the new therapeutic modalities for cancer treatment and is based on the difference in thermal sensitivity between healthy tissues and tumors. During hyperthermia treatment, the temperature of the tumor is raised to 40–45°C for a definite period resulting in the destruction of cancer cells. This paper investigates design, modeling and simulation of a new non-invasive hyperthermia applicator system capable of effectively heating deep seated as well as superficial brain tumors using inexpensive, simple, and easy to fabricate components without harming surrounding healthy brain tissues. Methods The proposed hyperthermia applicator system is composed of an air filled partial half ellipsoidal chamber, a patch antenna, and a head model with an embedded tumor at an arbitrary location. The irradiating antenna is placed at one of the foci of the hyperthermia chamber while the center of the brain tumor is placed at the other focus. The finite difference time domain (FDTD method is used to compute both the SAR patterns and the temperature distribution in three different head models due to two different patch antennas at a frequency of 915 MHz. Results The obtained results suggest that by using the proposed noninvasive hyperthermia system it is feasible to achieve sufficient and focused energy deposition and temperature rise to therapeutic values in deep seated as well as superficial brain tumors without harming surrounding healthy tissue. Conclusions The proposed noninvasive hyperthermia system proved suitable for raising the temperature in tumors embedded in the brain to therapeutic values by carefully selecting the systems components. The operator of the system only needs to place the center of the brain tumor at a pre-specified location and excite the antenna at a single frequency of 915 MHz. Our study may provide a basis for a clinical applicator prototype capable of heating brain tumors.

  6. Useful surgical techniques for facial nerve preservation in tumorous intra-temporal lesions.

    Science.gov (United States)

    Kim, Jin; Moon, In Seok; Lee, Jong Dae; Shim, Dae Bo; Lee, Won-Sang

    2010-02-01

    The management of the facial nerve in tumorous temporal lesions is particularly challenging due to its complex anatomic location and potential postoperative complications, including permanent facial paralysis. The most important concern regarding surgical treatment of a tumorous temporal lesion is the inevitable facial paralysis caused by nerve injury during the tumor removal, especially in patients with minimal to no preoperative facial nerve dysfunction. We describe successful four cases in which various surgical techniques were developed for the preservation of the facial nerve in treatment of intratemporal tumorous lesions. Copyright (c) 2009 Elsevier Ireland Ltd. All rights reserved.

  7. Signs and symptoms of patients with brain tumors presenting to the emergency department.

    Science.gov (United States)

    Snyder, H; Robinson, K; Shah, D; Brennan, R; Handrigan, M

    1993-01-01

    This retrospective chart review was conducted to determine the presenting signs and symptoms of patients with primary brain tumors diagnosed in the emergency department. There were 101 patients (65 males and 36 females) identified with a hospital discharge diagnosis of primary brain tumor who were admitted through the emergency department. The presenting symptoms included headache (56 patients), altered mental status (51 patients), ataxia (41 patients), nausea or vomiting (37 patients), weakness (27 patients), speech deficits (21 patients), and sensory abnormalities (18 patients). The presenting signs included motor weakness (37 patients), ataxia (37 patients), papilledema (28 patients), cranial nerve palsies (26 patients), visual deficits (20 patients), and speech deficits (12 patients). The average age was 42.8 years, with a range of 3 days to 88 years. The majority of tumors were malignant astrocytomas. Tumor location was cortical in 68 patients, subcortical in 9 patients, and brainstem or cerebellum in 24 patients. In conclusion, patients of all ages may present to the emergency department with a variety of symptoms resulting from a primary brain tumor. Headache and altered mental status were common in our series of patients, but symptoms will depend on the size, location, and type of tumor. A complete neurologic examination is essential, including evaluation for papilledema.

  8. Attachment of Free Filament Thermocouples for Temperature Measurements on CMC

    Science.gov (United States)

    Lei, Jih-Fen; Cuy, Michael D.; Wnuk, Stephen P.

    1997-01-01

    Ceramic Matrix Composites (CMC) are being developed for use as enabling materials for advanced aeropropulsion engine and high speed civil transport applications. The characterization and testing of these advanced materials in hostile, high-temperature environments require accurate measurement of the material temperatures. Commonly used wire Thermo-Couples (TC) can not be attached to this ceramic based material via conventional spot-welding techniques. Attachment of wire TC's with commercially available ceramic cements fail to provide sufficient adhesion at high temperatures. While advanced thin film TC technology provides minimally intrusive surface temperature measurement and has good adhesion on the CMC, its fabrication requires sophisticated and expensive facilities and is very time consuming. In addition, the durability of lead wire attachments to both thin film TC's and the substrate materials requires further improvement. This paper presents a newly developed attachment technique for installation of free filament wire TC's with a unique convoluted design on ceramic based materials such as CMC's. Three CMC's (SiC/SiC CMC and alumina/alumina CMC) instrumented with type IC, R or S wire TC's were tested in a Mach 0.3 burner rig. The CMC temperatures measured from these wire TC's were compared to that from the facility pyrometer and thin film TC's. There was no sign of TC delamination even after several hours exposure to 1200 C. The test results proved that this new technique can successfully attach wire TC's on CMC's and provide temperature data in hostile environments. The sensor fabrication process is less expensive and requires very little time compared to that of the thin film TC's. The same installation technique/process can also be applied to attach lead wires for thin film sensor systems.

  9.  An Uncommon Presentation of Giant Cell Tumor

    Directory of Open Access Journals (Sweden)

    Gopal Malhotra

    2011-09-01

    Full Text Available  Giant Cell Tumors commonly occur at the ends of long bones. However in rare cases, they can occur in the bones of the hands and feet. Tumors in these locations occur in younger patients; in addition, these tumors are more commonly multifocal and are associated with a higher risk for local recurrence than tumors at the ends of long bones. Since lesions in the small bones may be multifocal, a patient with a giant cell tumor of the small bones should undergo a skeletal survey to exclude similar lesions elsewhere. Primary surgical treatment ranges from curettage or excision with or without bone grafting to amputation. The success of surgical treatment depends on the completeness with which the tumor was removed. We are presenting a case report of a 34 year old female, who presented with a swelling in the right hand, following trauma. X-ray of the hand showed an osteolytic expansile lesion at the base of the 1st metacarpal bone. The lesion was initially curetted and then treated by local resection with bone grafting. Histological examination revealed a typical benign giant cell tumor composed of closely packed stromal cells with a variable admixture of giant cells. Follow up at the end of one year did not reveal any recurrence of the tumor.

  10. MRI diagnosis of embryonal tumors in the spinal canal

    International Nuclear Information System (INIS)

    Sun Jilin; Zhang Xinchuan; Zhang Huaning; Liu Lianxiang; Wu Yujin

    1997-01-01

    To evaluate MRI diagnostic value of the embryonal tumors in the spinal canal. Materials and methods: The MRI appearances of 15 cases of histologically confirmed embryonal tumors in the spinal canal were analyzed. (1) Lipoma (3 cases) had characteristic MRI appearance, demonstrating high signal intensity on T 1 WI, and moderately high signal on T 2 WI. High signal intensity of the lipoma was turned into low signal intensity by fat suppression technique. (2) Dermoids (2 cases) and epidermoid (7 cases) exhibiting low or iso-low signal on T 1 WI and high or iso-high signal on T 2 WI. All had an iso-intense capsule on T 1 WI. However, the two tumors could not be distinguished from each other. (3) Teratoma (3 cases) appeared as a mass of inhomo-generous signals in the spinal canal including soft tissue, fatty tissue and calcification within the same tumor. The diagnosis of embryonal tumors in the spinal canal mainly depend on their MRI appearances, specific tumor location and patient's age

  11. Oral tumors in dogs and cats. II. Prognosis and treatment

    International Nuclear Information System (INIS)

    Dhaliwal, R.S.; Kitchell, B.E.; Marretta, S.M.

    1998-01-01

    Small size and rostral location generally are positive prognostic factors for all types of oral tumors.:Standard treatment modalities for oral tumors include surgery, radiation therapy, intralesional matrix cisplatin, photodynamic therapy, and chemotherapy, Investigational therapeutic regimens, such as immunotherapy and gene therapy are not:yet widely available to practicing veterinarians. Surgery and radiation therapy are the-treatments of-choice for oral tumors because these neoplasms are locally aggressive and rarely metastasize. The advent of radical,surgical techniques coupled: with the use of radiation therapy has dramatically: improved survival Fates for dogs with oral tumors. When considered for oral tumors, chemotherapy is always palliative therapy because a complete cure cannot be anticipated with chemotherapy alone. However, using concurrent chemotherapy (as a radiation Sensitizer) and radiation therapy is gaining a lot of interest in clinical research. Part I of this two-part presentation discussed clinical Signs,diagnosis, and histologic types of various oral tumors; Part II reviews prognosis and treatment

  12. CT findings of skull tumors forming subcutaneous masses

    International Nuclear Information System (INIS)

    Niida, Hirohito; Takeda, Norio; Onda, Kiyoshi; Tanaka, Ryuichi

    1991-01-01

    Some characteristics of CT findings in 27 patients with skull tumors forming subcutaneous tumors were studied. There were sixteen metastatic skull tumors, six primary skull tumors, and five meningiomas. A CT scan was found to be helpful in the diagnosis of the lesions. Especially, bone-window CT images proved very sensitive in the detection of destructive and permeative lesions of the skull. In 19 of the 27 cases, some lytic lesions were observed. In all cases with skull metastasis from carcinomas, a complete osteolytic change of the skull was observed. Furthermore, all of the metastatic tumors from thyroid carcinoma showed well circumscribed and homogeneously enhanced lesions, in contrast with the other metastatic carcinomas, which usually showed heterogeneously enhanced lesions with irregular margins. Osteoblastic changes were characteristically observed in all cases of meningiomas, osteosarcoma, and chondrosarcoma. Meningiomas were located mainly in the intracranial region and extended extracranially. In one case of malignant lymphoma, one of a neuroblastoma, and one of leukemia, there was little or no gross cortical bone change, despite a large mass. (author)

  13. The location of locoregional recurrence in pathologic T3N0, non-irradiated lower rectal cancer

    International Nuclear Information System (INIS)

    Kim, Mi Sun; Keum, Ki Chang; Rhee, Woo Joong; Kim, Hyun Ju; Kim, Min Ji; Choi, Seo Hee; Nam, Ki Chang; Koom, Woong Sub

    2013-01-01

    To investigate the patterns of locoregional recurrence of pathologic T3N0 (pT3N0) lower rectal cancer omitting postoperative radiotherapy (RT) and explore the potential of modification of a RT field. From Jan 2003 to Nov 2011, 35 patients omitting preoperative or postoperative RT for pT3N0 lower rectal cancer were included. We defined the lower rectal cancer as the tumor with the inferior margin located below the virtual line-a convergent level between rectal wall and levator ani muscle. All patients had radiologic examinations for recurrence evaluation during the follow-up duration. The median follow-up duration was 66.4 months (range, 1.4 to 126.1 months). Eight (22.9%) of the 35 patients had recurrence. Three (8.6%) was local recurrence (LR) only, 3 (8.6%) was distant metastasis (DM) only, and 2 (5.7%) was LR with DM. All LR were located at primary tumor sites. The overall survival rate, LR-free survival rate, and DM-free survival rate at 5 years was 79.8%, 83%, and 87%, respectively. All LR developed from tumors over 5 cm. However, there was no statistical significance (p = 0.065). There was no other risk factor for LR. Even though the patients included in this study had pathologically favorable pT3N0 rectal cancer, LR developed in 14.3% of patients. Most of the LR was located at primary tumor sites prior to surgery. Based on these findings, it might seem reasonable to consider postoperative RT with a smaller radiation field to the primary tumor site rather than the conventional whole pelvic irradiation.

  14. Location of gliomas in relation to mobile telephone use: a case-case and case-specular analysis

    DEFF Research Database (Denmark)

    Larjavaara, Suvi; Schüz, Joachim; Swerdlow, Anthony

    2011-01-01

    approaches: In a case-case analysis, tumor locations were compared with varying exposure levels; in a case-specular analysis, a hypothetical reference location was assigned for each glioma, and the distances from the actual and specular locations to the handset were compared. The study included 888 gliomas......The energy absorbed from the radio-frequency fields of mobile telephones depends strongly on distance from the source. The authors' objective in this study was to evaluate whether gliomas occur preferentially in the areas of the brain having the highest radio-frequency exposure. The authors used 2...... from 7 European countries (2000-2004), with tumor midpoints defined on a 3-dimensional grid based on radiologic images. The case-case analyses were carried out using unconditional logistic regression, whereas in the case-specular analysis, conditional logistic regression was used. In the case-case...

  15. Dynamic Quantitative T1 Mapping in Orthotopic Brain Tumor Xenografts

    Directory of Open Access Journals (Sweden)

    Kelsey Herrmann

    2016-04-01

    Full Text Available Human brain tumors such as glioblastomas are typically detected using conventional, nonquantitative magnetic resonance imaging (MRI techniques, such as T2-weighted and contrast enhanced T1-weighted MRI. In this manuscript, we tested whether dynamic quantitative T1 mapping by MRI can localize orthotopic glioma tumors in an objective manner. Quantitative T1 mapping was performed by MRI over multiple time points using the conventional contrast agent Optimark. We compared signal differences to determine the gadolinium concentration in tissues over time. The T1 parametric maps made it easy to identify the regions of contrast enhancement and thus tumor location. Doubling the typical human dose of contrast agent resulted in a clearer demarcation of these tumors. Therefore, T1 mapping of brain tumors is gadolinium dose dependent and improves detection of tumors by MRI. The use of T1 maps provides a quantitative means to evaluate tumor detection by gadolinium-based contrast agents over time. This dynamic quantitative T1 mapping technique will also enable future quantitative evaluation of various targeted MRI contrast agents.

  16. Giant mediastinal schwannoma located in the lower right side of the ...

    African Journals Online (AJOL)

    2016-01-18

    Jan 18, 2016 ... nerve. The tumor was coated with a white envelope and filled. Giant mediastinal schwannoma located in the lower right side of the chest. Y Wu, J Zhang, Y Chai. Department of Thoracic Surgery, School of Medicine, Second Affiliated Hospital, Zhejiang University, Hangzhou, China. Access this article online.

  17. Papillary endothelial hyperplasia (Masson's tumor) in children.

    Science.gov (United States)

    Liné, A; Sanchez, J; Jayyosi, L; Birembaut, P; Ohl, X; Poli-Mérol, M-L; François, C

    2017-06-01

    The intravascular papillary endothelial hyperplasia (IPEH/Masson's tumor) is a rare benign tumor of the skin and subcutaneous vessels. We report, in four pediatric cases, clinical presentation, care (diagnostic and surgical) of Masson's tumor in children. Two boys (two years) and two girls (four and six years) showed a pain subcutaneous tumor (one to five centimeters). They were in the transverse abdominal muscle, between two metatarsals, at the front of thigh and in the axilla. Imaging performed (MRI, Doppler ultrasound) evoked either a hematoma, a lymphangioma or hemangioma. The indication for removal was selected from pain and/or parental concern. The diagnosis was histologically. A lesion persisted in residual form (incomplete initial resection), and is currently not scalable for eleven years. This tumor is characterized by excessive proliferation and papillary endothelial cells in the vessels, following a thrombotic event. It is found mainly in adults (no specific age), and preferentially localizes in the face and limbs. The clinical differential diagnosis of this tumor is angiosarcoma. The imagery has not allowed in our series to diagnose but still essential to eliminate differential diagnoses. Only surgical excision with histological examination can differentiate. Our study emphasizes the possibility of pediatric cases with two cases of unusual locations (abdominal and axilla). Clinical presentations we met, now lead us to direct our histologist looking for a Masson tumor in any child with a subcutaneous tumor and/or intramuscular pain, sudden onset, and vascular appearance (after excluding an arteriovenous malformation). Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  18. A proposed grading system for standardizing tumor consistency of intracranial meningiomas.

    Science.gov (United States)

    Zada, Gabriel; Yashar, Parham; Robison, Aaron; Winer, Jesse; Khalessi, Alexander; Mack, William J; Giannotta, Steven L

    2013-12-01

    grade was 0.87 (SE 0.06, 95% CI 0.76-0.99), with 90% user agreement. Kappa analysis scores for minimum and maximum grades of tumor regions were 0.69 (agreement 72%) and 0.75 (agreement 78%), respectively. The kappa analysis score for tumor vascularity grading was 0.56 (agreement 76%). Overall consistency did not correlate with patient age, tumor location, or tumor size. A higher tumor vascularity grade was associated with a larger tumor diameter (p = 0.045) and with skull base location (p = 0.02). The proposed grading system provides a reliable, practical, and objective assessment of meningioma consistency and facilitates communication among providers. This system also accounts for heterogeneity in tumor consistency. With the proposed scale, meningioma consistency can be standardized as groundwork for future studies relating to surgical outcomes, predictability of consistency and vascularity using neuroimaging techniques, and effectiveness of various surgical instruments.

  19. [Granular cell tumor of the larynx in the child. Case report].

    Science.gov (United States)

    Cuestas, Giselle; Rodríguez, Verónica; Doormann, Flavia; Bellia Munzón, Patricio; Bellia Munzón, Gastón

    2018-02-01

    Laryngeal tumors are uncommon in children, accounting only for 2% of the laryngeal anomalies. Ninety-eight percent are benign; the most frequent ones are recurrent respiratory papillomatosis and haemangioma. Granular cell tumor, also called Abrikossoff tumor, is an unusual benign neoplasm, especially in the larynx. Clinical manifestations depend on the size and location of the tumor. Dysphonia is the main presenting symptom. The diagnosis is confirmed by the biopsy. The treatment of choice is surgery. We present a 9-year-old girl with dysphonia and exertion dyspnea due to a granular cell tumor of the larynx, and we emphasize the importance of considering the endoscopic evaluation of the airway in every child with progressive or persistent dysphonia in order to determine the etiology. Sociedad Argentina de Pediatría.

  20. Tenosynovial Giant Cell Tumor: Better molecular understanding revolutionizes treatment outcome

    Directory of Open Access Journals (Sweden)

    Emad Shash

    2016-01-01

    Full Text Available Tenosynovial giant cell tumors (TGCTs are rare tumors, which are primarily treated via surgery with a low likelihood of metastasis. Although wide excision is an excellent choice for local control, tumors located within or close to major joints, along with the benign nature of the disease, make such resection impractical. An increase in local recurrences and the need for multiple surgical procedures promoted the interest in targeted-therapies for this disease. TGCTs contain a mixture of giant cells, mononuclear cells and inflammatory cells, with clonal cytogenetic abnormalities through rearrangements involving 1p11–13. Colony stimulating factor (CSF1 gene encodes for the ligand of CSF1 receptor (CSF1R. The CSF1 gene is located at the chromosome 1p13 breakpoint and is found to be translocated in 63%–77% of patients with TGCTs. Selective CSF1R inhibitors yield high response rate and disease control, demonstrating the integration of a new drug development technology that could revolutionize treatment outcomes.

  1. Factors affecting intellectual outcome in pediatric brain tumor patients

    International Nuclear Information System (INIS)

    Ellenberg, L.; McComb, J.G.; Siegel, S.E.; Stowe, S.

    1987-01-01

    A prospective study utilizing repeated intellectual testing was undertaken in 73 children with brain tumors consecutively admitted to Childrens Hospital of Los Angeles over a 3-year period to determine the effect of tumor location, extent of surgical resection, hydrocephalus, age of the child, radiation therapy, and chemotherapy on cognitive outcome. Forty-three patients were followed for at least two sequential intellectual assessments and provide the data for this study. Children with hemispheric tumors had the most general cognitive impairment. The degree of tumor resection, adequately treated hydrocephalus, and chemotherapy had no bearing on intellectual outcome. Age of the child affected outcome mainly as it related to radiation. Whole brain radiation therapy was associated with cognitive decline. This was especially true in children below 7 years of age, who experienced a very significant loss of function after whole brain radiation therapy

  2. Tumor odontógeno adenomatoide en región mandibular Adenomatoid odontogenic tumor in mandibular region

    Directory of Open Access Journals (Sweden)

    Ernesto Sánchez Cabrales

    2010-12-01

    Full Text Available El tumor odontogénico adenomatoide es un tumor poco frecuente derivado del epitelio odontontogénico, que contiene estructuras canaliculares con modificaciones inductivas de intensidad variable en el tejido conjuntivo. Es una lesión de crecimiento lento y poco invasiva pero que se puede asemejar a otras lesiones odontógenas de mayor agresividad como el quiste dentígero y el ameloblastoma entre otros. Su localización clásica (área de caninos superiores nos orienta al diagnóstico y su patrón histológico ductiforme es muy propio de este tumor. Otros tumores que se encuentran dentro de este grupo son el fibroma ameloblástico, el odontoameloblastoma, el quiste odontógeno calcificante y los odontomas compuesto y complejo. Este grupo de lesiones puede o no tener formaciones de tejido duro dental dentro de ellos. Por esta razón, se presenta un paciente con este tipo de tumor, al que se le realizó estudio histopatológico, se revisó la literatura acerca de este tumor odontogénico benigno y sus características clínicas, radiográficas, tratamiento, así como los diagnósticos diferenciales que se deben tener en cuenta.The adenomatoid odontogenic tumor is an uncommon neoplasm derivative of the odontogenic epithelium containing canalicular structures with inductor modifications of variable intensity in the conjunctival tissue. It is a slow growth lesion and no much invasive but that may to be similar to other odontogenic lesions more aggressive including the dentigerous cyst and the ameloblastoma among others. Its classical location (upper canine area guides us to diagnosis and its duct histological pattern is very typical of this tumor. Other tumors included in this group are the ameloblastic fibroma, the ameloblastic odontoma, the calcified odontogenic cyst and composed and complex odontomas. This group of lesions may or not to have formations of hard tissue inside. Thus, authors present the case of a patient presenting with this type of

  3. An unusual mixed tumor of the pancreas: sonographic and MDCT features.

    Science.gov (United States)

    Mortelé, Koenraad J; Peters, Hope E; Odze, Robert D; Glickman, Jonathan N; Jajoo, Kunal; Banks, Peter A

    2009-03-09

    Mixed tumors of the pancreas are exceedingly rare. We herein report on a 54-year-old female who presented with an enlarging cystic lesion in the head of the pancreas. Right upper quadrant ultrasound and multidetector-row CT scan showed a well-defined unilocular cystic tumor located in the head of the pancreas and surrounded, in part, by a hypervascular solid mass. Although mixed exocrine/endocrine pancreatic tumors have been described previously, to the best of our knowledge, this is the first case of a pancreatic mixed intraductal papillary mucinous neoplasm/endocrine tumor with illustration of its ultrasound and CT features. Moreover, the importance of preoperative analysis of imaging features in the assessment of pancreatic neoplasms is discussed.

  4. Simple and complex dysembryoplastic neuroepithelial tumors (DNT) variants: clinical profile, MRI, and histopathology

    Energy Technology Data Exchange (ETDEWEB)

    Campos, Alexandre R.; Clusmann, Hans; Lehe, Marec von; Schramm, Johannes [University of Bonn Medical Center, Department of Neurosurgery, Bonn (Germany); Niehusmann, Pitt; Becker, Albert J. [University of Bonn Medical Center, Department of Neuropathology, Bonn (Germany); Urbach, Horst [University of Bonn Medical Center, Department of Radiology, Bonn (Germany)

    2009-07-15

    Dysembryoplastic neuroepithelial tumors (DNTs) are long-term epilepsy associated tumors subdivided into simple and complex variants. The purpose of this study was to relate different DNT components identified on magnetic resonance imaging (MRI) to histopathological features and to test the hypothesis that glial nodules as a histopathological feature of complex variants induce an occasional glioma misdiagnosis. Clinical, MRI, and histopathologic features of DNTs operated between 1988 and 2008 were reviewed. From a total of 61 DNTs, 48 simple and 13 complex variants were identified. Multiple or single pseudocysts in a cortical/subcortical location with small cysts sometimes separated from the tumor represented the glioneuronal element and were found in all DNTs. FLAIR hyperintense tissue was found between pseudocysts but - in neocortical DNTs - also circumscript in deeper tumor parts. Calcification and hemorrhages in this location occurred in four of 13 complex variants, and one of these patients was also the only one with tumor growth. Patients with complex variants had earlier seizure onset, and complex variants were more often located outside the temporal lobe. Although complex variants represented a higher diagnostic challenge, misdiagnoses also occurred in simple variants. One of five of DNTs showed contrast enhancement, which varied on follow-up studies with enhancing parts becoming nonenhancing and vice versa. The glioneuronal element is readily identifiable on MRI and should be considered to support the DNT diagnosis. Complex DNT variants have a different clinical profile and a more variable histopathological and MRI appearance; however, misdiagnoses occasionally also occur in simple variants. (orig.)

  5. Ultrasound-guided percutaneous radiofrequency ablation of liver tumors: How we do it safety and completely

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Woong; Shin, Sang Soo; Heo, Suk Hee; Hong, Jun Hyung; Lim, Hyo Soon; Seon, Hyun Ju; Hur, Young Hoe; Park, Chang Hwan; Jeong, Yong Yeon; Kang, Heoung Keun [Chonnam National University Medical School, Gwangju (Korea, Republic of)

    2015-12-15

    Ultrasound-guided percutaneous radiofrequency (RF) ablation has become one of the most promising local cancer therapies for both resectable and nonresectable hepatic tumors. Although RF ablation is a safe and effective technique for the treatment of liver tumors, the outcome of treatment can be closely related to the location and shape of the tumors. There may be difficulties with RF ablation of tumors that are adjacent to large vessels or extrahepatic heat-vulnerable organs and tumors in the caudate lobe, possibly resulting in major complications or treatment failure. Thus, a number of strategies have been developed to overcome these challenges, which include artificial ascites, needle track ablation, fusion imaging guidance, parallel targeting, bypass targeting, etc. Operators need to use the right strategy in the right situation to avoid the possibility of complications and incomplete thermal tissue destruction; with the right strategy, RF ablation can be performed successfully, even for hepatic tumors in high-risk locations. This article offers technical strategies that can be used to effectively perform RF ablation as well as to minimize possible complications related to the procedure with representative cases and schematic illustrations.

  6. Correlation of primary tumor FDG uptake with histopathologic features of advanced gastric cancer

    International Nuclear Information System (INIS)

    Kim, Hae Won; Won, Kyoung Sook; Song, Bong Il; Kang, Yu Na

    2015-01-01

    Histopathologic features could affect the FDG uptake of primary gastric cancer and detection rate on FDG PET/CT. The aim of this study was to evaluate the FDG uptake of primary gastric cancer by correlating it with the histopathologic features of the tumors. Fifty patients with locally advanced gastric adenocarcinoma who were referred for preoperative FDG-PET/CT scans were enrolled in this study. The detection rate of PET/CT and maximum standardized uptake values (SUV max ) of the primary tumor were compared using the WHO, Lauren, Ming and Borrmann classifications and tumor size and location. In 45 of the 50 patients (90 %), the primary gastric tumors were detected by FDG PET/CT. On comparison using the WHO classification, the detection rate and SUV max of the tubular type were significantly higher than those of the poorly cohesive type. On comparison using the Lauren and Ming classifications, the SUV maxs of the intestinal type and expanding type were significantly higher than those of the diffuse and infiltrative type, respectively. On comparison using the Borrmann classification and tumor size and location, there was no significant difference in the detection rate and SUV max of primary gastric tumors. This study demonstrates that the poorly cohesive type according to the WHO classification, diffuse type according to the Lauren classification and infiltrative type according to the Ming classification have low FDG uptake in patients with locally advanced gastric carcinoma. Understanding the relationship between primary tumor FDG uptake and histopathologic features would be helpful in detecting the primary tumor by FDG PET/CT in patients with gastric cancer

  7. Study for on-line system to identify inadvertent control rod drops in PWR reactors using ex-core detector and thermocouple measures

    International Nuclear Information System (INIS)

    Souza, Thiago J.; Medeiros, Jose A.C.C.; Goncalves, Alessandro C.

    2015-01-01

    Accidental control rod drops event in PWR reactors leads to an unsafe operating condition. It is important to quickly identify the rod to minimize undesirable effects in such a scenario. In this event, there is a distortion in the power distribution and temperature in the reactor core. The goal of this study is to develop an on-line model to identify the inadvertent control rod dropped in PWR reactor. The proposed model is based on physical correlations and pattern recognition of ex-core detector responses and thermocouples measures. The results of the study demonstrated the feasibility of an on-line system, contributing to safer operation conditions and preventing undesirable effects, as its shutdown. (author)

  8. Study for on-line system to identify inadvertent control rod drops in PWR reactors using ex-core detector and thermocouple measures

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Thiago J.; Medeiros, Jose A.C.C.; Goncalves, Alessandro C., E-mail: tsouza@nuclear.ufrj.br, E-mail: canedo@lmp.ufrj.br, E-mail: alessandro@nuclear.ufrj.br [Coordenacao dos Programas de Pos-Graduacao em Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear

    2015-07-01

    Accidental control rod drops event in PWR reactors leads to an unsafe operating condition. It is important to quickly identify the rod to minimize undesirable effects in such a scenario. In this event, there is a distortion in the power distribution and temperature in the reactor core. The goal of this study is to develop an on-line model to identify the inadvertent control rod dropped in PWR reactor. The proposed model is based on physical correlations and pattern recognition of ex-core detector responses and thermocouples measures. The results of the study demonstrated the feasibility of an on-line system, contributing to safer operation conditions and preventing undesirable effects, as its shutdown. (author)

  9. Location, location, location: Extracting location value from house prices

    OpenAIRE

    Kolbe, Jens; Schulz, Rainer; Wersing, Martin; Werwatz, Axel

    2012-01-01

    The price for a single-family house depends both on the characteristics of the building and on its location. We propose a novel semiparametric method to extract location values from house prices. After splitting house prices into building and land components, location values are estimated with adaptive weight smoothing. The adaptive estimator requires neither strong smoothness assumptions nor local symmetry. We apply the method to house transactions from Berlin, Germany. The estimated surface...

  10. A 36-year-old female with Krukenberg tumor from a colonic carcinoma.

    Science.gov (United States)

    Umakanthan, Srikanth; Bukelo, Maryann M; Hardik, Khandelwal

    2015-01-01

    Krukenberg tumor is bilateral ovarian carcinoma's metastasizing most commonly from a gastric primary followed by a colon. We report a case of 36-year-old female with bilateral ovarian mass diagnosed as Krukenberg with a work up for locating the primary site. In this case, we discuss widely the clinical aspects with histopathological features and literature review of Krukenberg tumor.

  11. Subungual Hypervascular Soft Tissue Chondroma Mimicking a Glomus Tumor: A Case Report

    International Nuclear Information System (INIS)

    Park, Jong Chun; Lee, Young Hwan; Jung, Kyung Jae

    2009-01-01

    Soft tissue chondroma, or extraskeletal chondroma, is a relatively rare, benign cartilaginous tumor that occurs most frequently in the hands and feet - a subungual location is quite rare. The authors describe a subungual soft tissue chondroma in a 25-year-old man that was visualized as a hypervascular mass on color Doppler ultrasonography and initially misdiagnosed as a glomus tumor

  12. Subungual Hypervascular Soft Tissue Chondroma Mimicking a Glomus Tumor: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jong Chun; Lee, Young Hwan; Jung, Kyung Jae [Catholic University of Daegu, School of Medicine, Daegu (Korea, Republic of)

    2009-09-15

    Soft tissue chondroma, or extraskeletal chondroma, is a relatively rare, benign cartilaginous tumor that occurs most frequently in the hands and feet - a subungual location is quite rare. The authors describe a subungual soft tissue chondroma in a 25-year-old man that was visualized as a hypervascular mass on color Doppler ultrasonography and initially misdiagnosed as a glomus tumor

  13. Scintigraphic evaluation of soft tissue tumors with technetium(V)-99m dimercaptosuccinic acid, a new tumor seeking radiopharmaceutical

    International Nuclear Information System (INIS)

    Ohta, H.; Yoshizumi, M.; Endo, K.; Torizuka, K.; Yokoyama, A.; Yamamoto, K.

    1984-01-01

    Recently, a very promising tumor seeking agent, a Tc(V)-99m dimercaptosuccinic acid (Tc(V)-DMS), which was labelled under optimal pH 8 and very low SnCl/sub 2/ concentrations, has been developed. An equilibrium between a stable form and a dissociated form of anion TcO/sub 4//sup 3-/, structural similarity to PO/sub 4//sup 3-/, postulated for tumor uptake. And the authors have previously reported that Tc(V)-DMS scintigram would be useful in the diagnosis of medullary thyroid carcinoma. In an attempt to widen its applicability, the scintigraphic examinations of soft tissue tumors with Tc(V)-DMS and comparative study with Ga-67 citrate were performed in 58 patients. Scintigrams were made 60-120 min after i.v. administration of 10 mCi Tc(V)-DMS using a conventional gamma camera. Tc(V)-DMS was found to have superior sensitivity of 90% for malignant tumors (including aggressive fibromatosis) to that with Ga-67 citrate of 56%, but inferior specificity of 71% to that with Ga-67 citrate of 80%. And the accuracy of the scan in soft tissue tumors with Tc(V)-DMS and Ga-67 citrate was 78% and 71%, respectively. Although the accumulation of Tc(V)-DMS has been detected in some benign soft tissue tumors and the exact mechanism of Tc(V)-DMS accumulation remains to be elucidated, these data indicated that Tc(V)-DMS scintigraphy would be of great use in the detection of extension or location of malignant soft tissue tumors

  14. A randomized clinical trial of hyperthermia and radiation versus radiation alone for superficially located cancers

    International Nuclear Information System (INIS)

    Egawa, Sunao; Tsukiyama, Iwao; Watanabe, Shaw

    1989-01-01

    A randomized clinical trial was performed in order to evaluate the effect of combined hyperthermia and radiation for superficially located tumors. Ten institutions participated in this study and 92 evaluable patients were entered from September 1985 to March 1987 (44 patients for radiation plus hyperthermia and 48 for radiation only). Superficially located tumors, more than 3x3 cm in diameter, regardless of whether they were primary or metastatic, and of their histology, were included in the study. Radiotherapy was performed by the conventional fractionation method (2 Gyx5/week). Hyperthermia was conducted once a week. There was no statistical difference between the two groups regarding age, sex, the distribution of tumors and treatment parameters. The complete response (CR) and partial response (PR) rate for the hyperthermia plus radiation group was 81.8%, while the rate for the radiation alone group was 62.6% (p<0.05). Six factors were selected for analysis of the above effect by a multiple logistic model. Sex contributed the most (p=0.001), then the site of the tumor (p=0.016) and the method of treatment (p=0.023). Sex and the site influenced the results. Age, irradiation dose and frequency and duration of heating were not significant factors for response to treatment. (author)

  15. Small Submucosal Tumors of the Stomach: Differentiation of Gastric Schwannoma from Gastrointestinal Stromal Tumor with CT

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jin Wook; Choi, Dong Gil; Kim, Kyoung Mee; Sohn, Tae Sung; Lee, Jun Haeng; Kim, Hee Jung; Lee, Soon Jin [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2012-07-15

    To identify the CT features that help differentiate gastric schwannomas (GS) from small (5 cm or smaller) gastrointestinal stromal tumors (GIST) and to assess the growth rates of both tumors. We included 16 small GSs and 56 GISTs located in the stomach. We evaluated the CT features including size, contour, surface pattern, margins, growth pattern, pattern and degree of contrast enhancement, and the presence of intralesional low attenuation area, hemorrhage, calcification, surface dimpling, fistula, perilesional lymph nodes (LNs), invasion to other organs, metastasis, ascites, and peritoneal seeding. We also estimated the tumor volume doubling time. Compared with GISTs, GSs more frequently demonstrated a homogeneous enhancement pattern, exophytic or mixed growth pattern, and the presence of perilesional LNs (each p < 0.05). The intralesional low attenuation area was more common in GISTs than GSs (p < 0.05). Multivariate analyses indicated that a homogeneous enhancement pattern, exophytic or mixed growth pattern, and the presence of perilesional LNs were statistically significant (p < 0.05). Tumor volume doubling times for GSs (mean, 1685.4 days) were significantly longer than that of GISTs (mean, 377.6 days) (p = 0.004). Although small GSs and GISTs show similar imaging findings, GSs more frequently show an exophytic or mixed growth pattern, homogeneous enhancement pattern, perilesional LNs and grow slower than GISTs.

  16. Small Submucosal Tumors of the Stomach: Differentiation of Gastric Schwannoma from Gastrointestinal Stromal Tumor with CT

    International Nuclear Information System (INIS)

    Choi, Jin Wook; Choi, Dong Gil; Kim, Kyoung Mee; Sohn, Tae Sung; Lee, Jun Haeng; Kim, Hee Jung; Lee, Soon Jin

    2012-01-01

    To identify the CT features that help differentiate gastric schwannomas (GS) from small (5 cm or smaller) gastrointestinal stromal tumors (GIST) and to assess the growth rates of both tumors. We included 16 small GSs and 56 GISTs located in the stomach. We evaluated the CT features including size, contour, surface pattern, margins, growth pattern, pattern and degree of contrast enhancement, and the presence of intralesional low attenuation area, hemorrhage, calcification, surface dimpling, fistula, perilesional lymph nodes (LNs), invasion to other organs, metastasis, ascites, and peritoneal seeding. We also estimated the tumor volume doubling time. Compared with GISTs, GSs more frequently demonstrated a homogeneous enhancement pattern, exophytic or mixed growth pattern, and the presence of perilesional LNs (each p < 0.05). The intralesional low attenuation area was more common in GISTs than GSs (p < 0.05). Multivariate analyses indicated that a homogeneous enhancement pattern, exophytic or mixed growth pattern, and the presence of perilesional LNs were statistically significant (p < 0.05). Tumor volume doubling times for GSs (mean, 1685.4 days) were significantly longer than that of GISTs (mean, 377.6 days) (p = 0.004). Although small GSs and GISTs show similar imaging findings, GSs more frequently show an exophytic or mixed growth pattern, homogeneous enhancement pattern, perilesional LNs and grow slower than GISTs.

  17. Tumor induction and hair follicle damage for different electron penetrations in rat skin

    International Nuclear Information System (INIS)

    Burns, F.J.; Sinclair, I.P.; Albert, R.E.; Vanderlaan, M.

    1976-01-01

    The penetration and dose of an electron beam were varied in an attempt to locate the depth in growing-phase rat skin where irradiation was most effective in inducing tumors and morphological damage to the hair follicles. The hair was plucked to initiate the growing phase of the hair cycle, and 12 days later the dorsal skin was irradiated with electrons penetrating 0.5, 1.0, or 2.0 mm at doses from 500 to 4000 rad. Differences in the curves of tumor incidence as a function of dose for different penetrations were best resolved by plotting the results against the 0.4 mm dose, while comparable curves for destruction of the follicles were best resolved by the 0.8 mm dose. Since 0.8 mm corresponded approximately to the depth of the follicles, these results indicated that the target tissues for follicular damage and tumor induction were separated in depth and that the target for tumor induction was probably located in the region above or near the midpoint of the follicles. When the radiation penetrated sufficiently to reach the entire follicle, the number of tumors produced was not significantly greater than the number observed previously in resting-phase skin, and it was inferred that the additional size and greater mitotic activity of the growing-phase follicles at the time of irradiation did not increase the probability of tumor induction

  18. CT morphology of benign median nerve tumors; Report of three cases and a review

    Energy Technology Data Exchange (ETDEWEB)

    Feyerabend, T; Schmitt, R; Lanz, U; Warmuth-Metz, M [Wuerzburg Univ. (Germany, F.R.). Abt. fuer Roentgendiagnostik Wuerzburg Univ. (Germany, F.R.). Abt. fuer Hand- und Mikrochirurgie

    1990-01-01

    Computed tomography (CT) was performed in 3 patients with benign tumors of the median nerve, histologically confirmed as neurilemmoma, fibrolipoma and hemangioma. The neurilemmoma showed a ring-shaped contrast enhancement. The fibrolipoma presented with areas of solid soft tissue and areas of fat. The hemangioma was a solid tumor with a lacunar, vascular contrast enhancement. According to our experience and to the previous literature CT gives useful information regarding the anatomic location, size, and relationship of peripheral nerve sheath tumors to surrounding structures, and may help to differentiate between various tumor types. (orig.).

  19. A Primary Pulmonary Glomus Tumor: A Case Report and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Yasushi Ariizumi

    2012-01-01

    Full Text Available A case of a glomus tumor originating from the lung is reported. A 43-year-old female had undergone resection of a right lung tumor following a clinical diagnosis of carcinoid, sclerosing hemangioma, or other sarcoma. Histologically, the tumor comprised uniform small round to oval cells with centrally located nucleus, a clear cytoplasm, and apparent cell borders. The tumor also showed a focally hemangiopericytomatous pattern with irregularly branching or dilated vessels. Electron microscopy revealed smooth muscle differentiation of the tumor cells. Immunostaining further revealed that the tumor cells expressed smooth muscle actin, h-caldesmon, muscle specific actin (HHF-35, but not cytokeratin, epithelial membrane antigen, synaptophysin, or chromogranin A. Based on these findings, a diagnosis of primary pulmonary glomus tumor was established. Glomus tumors of the lung are very rare and only 21 cases have been reported to date. The histological features of the present tumor and the relevant literature are discussed.

  20. Characterization of adjacent breast tumors using oligonucleotide microarrays

    International Nuclear Information System (INIS)

    Unger, Meredith A; Rishi, Mazhar; Clemmer, Virginia B; Hartman, Jennifer L; Keiper, Elizabeth A; Greshock, Joel D; Chodosh, Lewis A; Liebman, Michael N; Weber, Barbara L

    2001-01-01

    Current methodology often cannot distinguish second primary breast cancers from multifocal disease, a potentially important distinction for clinical management. In the present study we evaluated the use of oligonucleotide-based microarray analysis in determining the clonality of tumors by comparing gene expression profiles. Total RNA was extracted from two tumors with no apparent physical connection that were located in the right breast of an 87-year-old woman diagnosed with invasive ductal carcinoma (IDC). The RNA was hybridized to the Affymetrix Human Genome U95A Gene Chip ® (12,500 known human genes) and analyzed using the Gene Chip Analysis Suite ® 3.3 (Affymetrix, Inc, Santa Clara, CA, USA) and JMPIN ® 3.2.6 (SAS Institute, Inc, Cary, NC, USA). Gene expression profiles of tumors from five additional patients were compared in order to evaluate the heterogeneity in gene expression between tumors with similar clinical characteristics. The adjacent breast tumors had a pairwise correlation coefficient of 0.987, and were essentially indistinguishable by microarray analysis. Analysis of gene expression profiles from different individuals, however, generated a pairwise correlation coefficient of 0.710. Transcriptional profiling may be a useful diagnostic tool for determining tumor clonality and heterogeneity, and may ultimately impact on therapeutic decision making