WorldWideScience

Sample records for thermistors flexible thermocouple

  1. Evaluation of Thermometrics thermistors for use at cryogenic temperatures

    International Nuclear Information System (INIS)

    Orvis, W.J.

    1981-01-01

    Two types of Thermometrics, Inc. thermistors have been evaluated at cryogenic temperatures by calibrating them against a type T thermocouple. They are both bare bead thermistors types BB25JE350R and BB25JE020M. The resistance of the thermistors was measured using a Hewlett-Packard 3467A Logging Multimeter which uses a constant current method of resistance measurement. Favorable results were obtained for the second type of thermistor down to the boiling point of liquid nitrogen (-196 0 C) be decreasing the interrogation current of the multimeter. This decrease was necessary to minimize self-heating effects. (orig.)

  2. Error analysis of thermocouple measurements in the Radiant Heat Facility

    International Nuclear Information System (INIS)

    Nakos, J.T.; Strait, B.G.

    1980-12-01

    The measurement most frequently made in the Radiant Heat Facility is temperature, and the transducer which is used almost exclusively is the thermocouple. Other methods, such as resistance thermometers and thermistors, are used but very rarely. Since a majority of the information gathered at Radiant Heat is from thermocouples, a reasonable measure of the quality of the measurements made at the facility is the accuracy of the thermocouple temperature data

  3. SSPX thermistor system

    International Nuclear Information System (INIS)

    Thomassen, K I

    2000-01-01

    The SSPX Thermistor is a glass encapsulated bead thermistor made by Thermometrics, a BR 14 P A 103 J. The BR means ruggedized bead structure, 14 is the nominal bead diameter in mils, P refers to opposite end leads, A is the material system code letter, 103 refers to its 10 k(Omega) zero-power resistance at 25 C, and the tolerance letter J indicates ± 5% at 25 C. It is football shaped, with height ->, and is viewed through a slot of height h = 0.01 inches. The slot is perpendicular to the long axis of the bead, and is a distance s ∼ 0.775 cm in front of the thermistor. So plasma is viewed over a large angle along the slot, but over a small angle α perpendicular to the slot. The angle α is given by 2s tanα = -> + h

  4. Attractive mechanical properties of a lightweight highly sensitive bi layer thermistor: polycarbonate/organic molecular conductor

    International Nuclear Information System (INIS)

    Laukhina, E; Lebedev, V; Rovira, C; Laukhin, V; Veciana, J

    2016-01-01

    The paper covers some of the basic mechanical characteristics of a recently developed bi layer thermistor: polycarbonate/(001) oriented layer of organic molecular conductor α’-(BEDT-TTF) 2 I x Br 3-x , were BEDT-TTF=bis(ethylenedithio)tetrathiafulvalen. The nano and macro mechanical properties have been studied in order to use this flexible, low cost thermistor in sensing applications by proper way. The nano-mechanical properties of the temperature sensitive semiconducting layer of α’-(BEDT-TTF) 2 I x Br 3-x were tested using nanoindentation method. The value of Young's modulus in direction being perpendicular to the layer plan was found as 9.0 ±1.4 GPa. The macro mechanical properties of the thermistor were studied using a 5848 MicroTester. The tensile tests showed that basic mechanical characteristics of the thermistor are close to those of polycarbonate films. This indicates a good mechanical strength of the developed sensor. Therefore, the thermistor can be used in technologies that need to be instrumented with highly robustness lightweight low cost temperature sensors. The paper also reports synthetic details on fabricating temperature sensing e-textile. As the temperature control is becoming more and more important in biomedical technologies like healthcare monitoring, this work strongly contributes on the ongoing research on engineering sensitive conducting materials for biomedical applications. (paper)

  5. Particle detection with semiconductor thermistors at low temperatures

    International Nuclear Information System (INIS)

    Wang, N.; Beeman, J.; Cleland, A.N.

    1988-11-01

    We have studied the use of neutron transmutation doped (NTD) Ge thermistors as phonon sensors at dilution refrigerator temperatures. In addition to measuring their thermal and electrical properties, we have observed pulses generated by X-rays incident on a thermistor thermally well-clamped to a heat sink. We find that during these pulses the lattice temperature of the thermistor apparently does not change. This surprising result is interpreted as evidence of a strong coupling between the high energy phonons generated by the interaction and the charge carriers in the thermistor. Additionally, these phonons appear to be absorbed within a fraction of a millimeter. We conclude that these thermistors have several desirable properties for a good high energy phonon sensor. It remains to be seen, however, if a composite detector consisting of a large crystal and attached phonon sensors can be developed. 15 refs., 9 figs

  6. Particle detection with semiconductor thermistors at low temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Wang, N.; Beeman, J.; Cleland, A.N.; Cummings, A.; Lange, A.; Ross, R.; Sadoulet, B.; Steiner, H.; Shutt, T.; Wellstood, F.C.

    1988-11-01

    We have studied the use of neutron transmutation doped (NTD) Ge thermistors as phonon sensors at dilution refrigerator temperatures. In addition to measuring their thermal and electrical properties, we have observed pulses generated by X-rays incident on a thermistor thermally well-clamped to a heat sink. We find that during these pulses the lattice temperature of the thermistor apparently does not change. This surprising result is interpreted as evidence of a strong coupling between the high energy phonons generated by the interaction and the charge carriers in the thermistor. Additionally, these phonons appear to be absorbed within a fraction of a millimeter. We conclude that these thermistors have several desirable properties for a good high energy phonon sensor. It remains to be seen, however, if a composite detector consisting of a large crystal and attached phonon sensors can be developed. 15 refs., 9 figs.

  7. A Miniaturized Nickel Oxide Thermistor via Aerosol Jet Technology.

    Science.gov (United States)

    Wang, Chia; Hong, Guan-Yi; Li, Kuan-Ming; Young, Hong-Tsu

    2017-11-12

    In this study, a miniaturized thermistor sensor was produced using the Aerosol Jet printing process for temperature sensing applications. A nickel oxide nanoparticle ink with a large temperature coefficient of resistance was fabricated. The thermistor was printed with a circular NiO thin film in between the two parallel silver conductive tracks on a cutting tool insert. The printed thermistor, which has an adjustable dimension with a submillimeter scale, operates over a range of 30-250 °C sensitively (B value of ~4310 K) without hysteretic effects. Moreover, the thermistor may be printed on a 3D surface through the Aerosol Jet printing process, which has increased capability for wide temperature-sensing applications.

  8. Thermocouple

    International Nuclear Information System (INIS)

    Charlesworth, F.D.W.

    1983-01-01

    A thermocouple is provided by a cable of coaxial form with inner and outer conductors of thermocouple forming materials and with the conductors electrically joined together at one end of the cable to form the thermocouple junction. The inner and outer conductors are preferably of chromel and stainless steel respectively. (author)

  9. Characterization and comparison of thermistor thick films. Topical report

    International Nuclear Information System (INIS)

    Gehman, R.W.

    1981-09-01

    Four thermistor thick film inks were evaluated for HMC production use. The physical, chemical and electrical properties of the wet inks and fired films were measured. Variations in the physical and chemical properties of the inks were used to explain variations in thermistor electrical resistance and temperature coefficient of resistance

  10. A Study of Thermistor Performance within a Textile Structure

    Directory of Open Access Journals (Sweden)

    Theodore Hughes-Riley

    2017-08-01

    Full Text Available Textiles provide an ideal structure for embedding sensors for medical devices. Skin temperature measurement is one area in which a sensor textile could be particularly beneficial; pathological skin is normally very sensitive, making the comfort of anything placed on that skin paramount. Skin temperature is an important parameter to measure for a number of medical applications, including for the early detection of diabetic foot ulcer formation. To this end an electronic temperature-sensor yarn was developed by embedding a commercially available thermistor chip into the fibres of a yarn, which can be used to produce a textile or a garment. As part of this process a resin was used to encapsulate the thermistor. This protects the thermistor from mechanical and chemical stresses, and also allows the sensing yarn to be washed. Building off preliminary work, the behaviour and performance of an encapsulated thermistor has been characterised to determine the effect of encapsulation on the step response time and absolute temperature measurements. Over the temperature range of interest only a minimal effect was observed, with step response times varying between 0.01–0.35 s. A general solution is presented for the heat transfer coefficient compared to size of the micro-pod formed by the encapsulation of the thermistor. Finally, a prototype temperature-sensing sock was produced using a network of sensing yarns as a demonstrator of a system that could warn of impending ulcer formation in diabetic patients.

  11. Characterizing Background Events in Neutron Transmutation Doped Thermistors for CUORE-0

    Science.gov (United States)

    Dutta, Suryabrata; Cuore Collaboration

    2017-09-01

    The Cryogenic Underground Observatory for Rare Events (CUORE) is a ton-scale neutrinoless double-beta decay experiment operating at the Laboratori Nazionali del Gran Sasso (LNGS). The experiment is comprised of 988 TeO2 bolometric crystals arranged into 19 towers and operated at a temperature of 15 mK. A neutron-transmutation-doped (NTD) Ge thermistor measures the thermal response from particles incident on the crystals. However, bulk and surface contamination of the NTD thermistors themselves produce distorted thermal responses inside the thermistor volume. Although these pulses are efficiently removed from the double-beta decay analysis by pulse shape cuts, they can be used to extract information about thermistor contamination. I will present a multifaceted approach to characterize these events, in which I implement an improved hot-electron thermal model, Geant4 Monte Carlo simulations of background events, and data from a previous experiment, CUORE-0, reprocessed with a new optimal filter. Using this approach, rates and energy deposition from contamination inside the NTD thermistors are measured, giving us better understanding of a CUORE background source.

  12. Composite thermocouples

    International Nuclear Information System (INIS)

    Debeir, R.P.

    1975-01-01

    As a rule, a composite thermocouple is a thermocouple where one or more components (wires, sheath, insulation) differ in kind between the hot junction measurement point and the cold termination with ordinary cables going on to measurement instrumentation. Three categories of such thermocouples are discussed: composite thermocouples having in common the continuity of the thermoelement wires over complete length, and different sheaths and insulation for the high temperature and intermediate temperature parts; those with different thermoelement wires, sheaths, and insulators for the high and intermediate temperature parts; a third category includes the high temperature thermoelements insulated by Al 2 O 3 or BeO and sheathed with a refractory metal, and with the intermediate temperature part made of 2Cr-Al couples, MgO insulated, and stainless steel or inconel sheathed

  13. The effect of skin thermistor fixation method on weighted mean skin temperature

    International Nuclear Information System (INIS)

    Tyler, Christopher James

    2011-01-01

    The purpose of this study was to investigate the effect of three different skin thermistor attachment methods on weighted mean skin temperature (WMT sk ) at three different ambient temperatures (∼24 °C (TEMP); ∼30 °C (WARM); ∼35 °C (HOT)) compared to uncovered thermistors. Eleven, non-acclimated, volunteers completed three 5 min bouts of submaximal cycling (∼70 W mechanical work)—one at each environmental condition in sequential order (TEMP, WARM, HOT). One thermistor was fixed to the sternal notch whilst four skin thermistors were spaced at 3 cm intervals on each of the sites on the limbs as per the formula of Ramanathan (1964 J. Appl. Physiol. 19 531–3). Each thermistor was either held against the skin uncovered (UC) or attached with surgical acrylic film dressing (T); surgical acrylic film dressing and hypoallergenic surgical tape (TT) or surgical acrylic film dressing, hypoallergenic surgical tape and surgical bandage (TTC). The WMT sk calculated was significantly lower in UC compared to T, TT and TTC (p < 0.001, d = 0.46), in T compared to TT and TTC (p < 0.001, d = 0.33) and in TT compared to TTC (p < 0.001; d = 0.25). The mean differences (across the three temperatures) were + 0.27 ±0.34 °C, + 0.52 ± 0.35 °C and + 0.82 ± 0.34 °C for T, TT and TTC, respectively. The results demonstrate that the method of skin thermistor attachment can result in the significant over-estimation of weighted mean skin temperature

  14. The validity of wireless iButtons® and thermistors for human skin temperature measurement

    International Nuclear Information System (INIS)

    Smith, A D Harper; Walsh, N P; Crabtree, D R; Bilzon, J L J

    2010-01-01

    Skin temperature is a fundamental variable in human thermo-physiology, and yet skin temperature measurement remains impractical in most free-living, exercise and clinical settings, using currently available hard-wired methods. The purpose of this study was to compare wireless iButtons® and hard-wired thermistors for human skin temperature measurement. In the first of two investigations, iButtons® and thermistors monitored temperature in a controlled water bath (range: 10–40 °C) and were referenced against a certified, mercury thermometer. In the second investigation, eight healthy males completed three randomized trials (ambient temperature = 10 °C, 20 °C and 30 °C) while both devices recorded skin temperature at rest (in low and high wind velocities) and during cycle-ergometry exercise. The results are as follows; Investigation 1: both devices displayed very high validity correlation with the reference thermometer (r > 0.999). Prior to correction, the mean bias was +0.121 °C for iButtons® and +0.045 °C for thermistors. Upon calibration correction the mean bias for iButtons® and thermistors was not significantly different from zero bias. Interestingly, the typical error of the estimate of iButtons® (0.043 °C) was 1.5 times less than that of thermistors (0.062 °C), demonstrating iButtons'® lower random error. Investigation 2: the offset between iButton® and thermistor readings was generally consistent across conditions; however, thermistor responses gave readings that were always closer to ambient temperature than those given by iButtons®, suggesting potential thermistor drift towards environmental conditions. Mean temperature differences between iButtons® and thermistors during resting trials ranged from 0.261 °C to 1.356 °C. Mean temperature differences between iButtons® and thermistors during exercise were 0.989 °C (ambient temperature = 10 °C), 0.415 °C (ambient temperature = 20 °C) and 0.318 °C (ambient temperature = 30 °C). Observed

  15. Subsampled Numerical Experiments as a Guide for Field Deployment of Thermistor Chains

    Science.gov (United States)

    Shaw, Justin; Stastna, Marek

    2017-11-01

    Thermistor chains are a standard tool for recording temperature profiles in geophysical flows. Density values can be inferred from readings and the resulting density field analyzed for the passage of internal waves, Kelvin-Helmholtz billows, and other dynamic events. The number and spacing of the thermistors, both on and between chains, determines which events can be identified in the dataset. We examine the effect of changing these variables by subsampling a set of numerical experiments to simulate thermistor chain locations. A pseudo spectral method was used to solve the incompressible Navier-Stokes equations under the Boussinesq approximation. The resulting flows are a set of high resolution seiches where the depth was held constant across experiments, and the length was varied. Sampling a known, commonly occurring flow with relatively simple geometry allows for a clear analysis of the effects of thermistor placement in the capture of dynamic events. We will discuss three dimensional deployment strategies, as well as EOF and DMD analyses if there is time. Funded by a Grant from the National Sciences and Engineering Research Council of Canada.

  16. Design and construction of an instrument for measuring thermistor electrical characteristic

    International Nuclear Information System (INIS)

    Budiono; Yudi Herdiana

    2007-01-01

    In this work an instrument for measuring the electrical characteristic of thermistor has been designed and constructed. The instrument was constructed from main components i.e. a micro controller AT89C51, 3 ADC-0804, a LM35 temperature sensor and IC MAX 232. The IC MAX 232 component is used to connect the micro controller to the personal computer serially by using RS-232 standard. While ADC-0804 was used to convert the analog data (DC voltage) to the digital one so that the data was readable by the micro controller. Digital data from 3 ADC-0804 circuit which have been read by the micro controller was sent directly to the personal computer. The data from the measurement which have been stored in the personal computer was then processed to know the value of temperature and measured thermistor resistance. The processed data could be either stored in a data base or displayed in a monitor or printed in the form of table data and in the form a graph of thermistor resistance as the function of temperature. The result of measurement from measuring instrument of the characteristic of thermistor electric's had been made, being compared by measuring calibrated instrument, the deviation is about 0.33 %. (author)

  17. Thin film ceramic thermocouples

    Science.gov (United States)

    Gregory, Otto (Inventor); Fralick, Gustave (Inventor); Wrbanek, John (Inventor); You, Tao (Inventor)

    2011-01-01

    A thin film ceramic thermocouple (10) having two ceramic thermocouple (12, 14) that are in contact with each other in at least on point to form a junction, and wherein each element was prepared in a different oxygen/nitrogen/argon plasma. Since each element is prepared under different plasma conditions, they have different electrical conductivity and different charge carrier concentration. The thin film thermocouple (10) can be transparent. A versatile ceramic sensor system having an RTD heat flux sensor can be combined with a thermocouple and a strain sensor to yield a multifunctional ceramic sensor array. The transparent ceramic temperature sensor that could ultimately be used for calibration of optical sensors.

  18. Neutron Transmutation Doped (NTD) germanium thermistors for sub-mm bolometer applications

    Science.gov (United States)

    Haller, E. E.; Itoh, K. M.; Beeman, J. W.

    1996-01-01

    Recent advances in the development of neutron transmutation doped (NTD) semiconductor thermistors fabricated from natural and controlled isotopic composition germanium are reported. The near ideal doping uniformity that can be achieved with the NTD process, the device simplicity of NTD Ge thermistors and the high performance of cooled junction field effect transistor preamplifiers led to the widespread acceptance of these thermal sensors in ground-based, airborne and spaceborne radio telescopes. These features made possible the development of efficient bolometer arrays.

  19. Temperature monitoring device and thermocouple assembly therefor

    Science.gov (United States)

    Grimm, Noel P.; Bauer, Frank I.; Bengel, Thomas G.; Kothmann, Richard E.; Mavretish, Robert S.; Miller, Phillip E.; Nath, Raymond J.; Salton, Robert B.

    1991-01-01

    A temperature monitoring device for measuring the temperature at a surface of a body, composed of: at least one first thermocouple and a second thermocouple; support members supporting the thermocouples for placing the first thermocouple in contact with the body surface and for maintaining the second thermocouple at a defined spacing from the body surface; and a calculating circuit connected to the thermocouples for receiving individual signals each representative of the temperature reading produced by a respective one of the first and second thermocouples and for producing a corrected temperature signal having a value which represents the temperature of the body surface and is a function of the difference between the temperature reading produced by the first thermocouple and a selected fraction of the temperature reading provided by the second thermocouple.

  20. Fabrication of amorphous InGaZnO thin-film transistor-driven flexible thermal and pressure sensors

    International Nuclear Information System (INIS)

    Park, Ick-Joon; Jeong, Chan-Yong; Song, Sang-Hun; Kwon, Hyuck-In; Cho, In-Tak; Lee, Jong-Ho; Cho, Eou-Sik; Kwon, Sang Jik; Kim, Bosul; Cheong, Woo-Seok

    2012-01-01

    In this work, we present the results concerning the use of amorphous indium–gallium–zinc–oxide (a-IGZO) thin-film transistor (TFT) as a driving transistor of the flexible thermal and pressure sensors which are applicable to artificial skin systems. Although the a-IGZO TFT has been attracting much attention as a driving transistor of the next-generation flat panel displays, no study has been performed about the application of this new device to the driving transistor of the flexible sensors yet. The proposed thermal sensor pixel is composed of the series-connected a-IGZO TFT and ZnO-based thermistor fabricated on a polished metal foil, and the ZnO-based thermistor is replaced by the pressure sensitive rubber in the pressure sensor pixel. In both sensor pixels, the a-IGZO TFT acts as the driving transistor and the temperature/pressure-dependent resistance of the ZnO-based thermistor/pressure-sensitive rubber mainly determines the magnitude of the output currents. The fabricated a-IGZO TFT-driven flexible thermal sensor shows around a seven times increase in the output current as the temperature increases from 20 °C to 100 °C, and the a-IGZO TFT-driven flexible pressure sensors also exhibit high sensitivity under various pressure environments. (paper)

  1. Attaching Thermocouples by Peening or Crimping

    Science.gov (United States)

    Murtland, Kevin; Cox, Robert; Immer, Christopher

    2006-01-01

    Two simple, effective techniques for attaching thermocouples to metal substrates have been devised for high-temperature applications in which attachment by such conventional means as welding, screws, epoxy, or tape would not be effective. The techniques have been used successfully to attach 0.005- in. (0.127-mm)-diameter type-S thermocouples to substrates of niobium alloy C-103 and stainless steel 416 for measuring temperatures up to 2,600 F (1,427 C). The techniques are equally applicable to other thermocouple and substrate materials. In the first technique, illustrated in the upper part of the figure, a hole slightly wider than twice the diameter of one thermocouple wire is drilled in the substrate. The thermocouple is placed in the hole, then the edge of the hole is peened in one or more places by use of a punch (see figure). The deformed material at the edge secures the thermocouple in the hole. In the second technique a hole is drilled as in the first technique, then an annular relief area is machined around the hole, resulting in structure reminiscent of a volcano in a crater. The thermocouple is placed in the hole as in the first technique, then the "volcano" material is either peened by use of a punch or crimped by use of sidecutters to secure the thermocouple in place. This second technique is preferable for very thin thermocouples [wire diameter .0.005 in. (.0.127 mm)] because standard peening poses a greater risk of clipping one or both of the thermocouple wires. These techniques offer the following advantages over prior thermocouple-attachment techniques: . Because these techniques involve drilling of very small holes, they are minimally invasive . an important advantage in that, to a first approximation, the thermal properties of surrounding areas are not appreciably affected. . These techniques do not involve introduction of any material, other than the substrate and thermocouple materials, that could cause contamination, could decompose, or oxidize

  2. Travelling gradient thermocouple calibration

    International Nuclear Information System (INIS)

    Broomfield, G.H.

    1975-01-01

    A short discussion of the origins of the thermocouple EMF is used to re-introduce the idea that the Peltier and Thompson effects are indistinguishable from one another. Thermocouples may be viewed as devices which generate an EMF at junctions or as integrators of EMF's developed in thermal gradients. The thermal gradient view is considered the more appropriate, because of its better accord with theory and behaviour, the correct approach to calibration, and investigation of service effects is immediately obvious. Inhomogeneities arise in thermocouples during manufacture and in service. The results of travelling gradient measurements are used to show that such effects are revealed with a resolution which depends on the length of the gradient although they may be masked during simple immersion calibration. Proposed tests on thermocouples irradiated in a nuclear reactor are discussed

  3. Study of thermocouples for control of high temperatures; Etude de thermocouples pour le reperage des hautes temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Villamayor, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires; Faculte des Sciences de l' Universite de Lyon - 69 (France)

    1967-07-01

    Previous works have shown that the tungsten-rhenium alloys thermocouples were a good instrument for control of high temperatures. From its, the author has studied the W/W 26 per cent and W 5 per cent Re/W 26 per cent Re french manufactured thermocouples and intended for control of temperatures in nuclear reactors until 2300 deg. C. In 'out-pile' study he determines the general characteristics of these thermocouples: average calibration curves, thermal shocks influence, response times, and alloys allowing the cold source compensation. The evolution of these thermocouples under thermal neutron flux has been determined by 'in-pile' study. The observations have led the author to propose a new type of thermocouples settled of molybdenum-columbium alloys. (author) [French] Des travaux anterieurs ont montre que les thermocouples des alliages tungstene-rhenium etaient susceptibles de reperer avec precision des hautes temperatures. A partir de la, l'auteur a etudie las thermocouples W/W 26 pour cent Re et W 5 pour cent Re/W 26 pour cent Re de fabrication francaise et destines au controle des temperatures dans les reacteurs nucleaires, jusqu'a 2300 deg. C Dans l'etude 'hors-pile' il a determine les caracteristiques generales de ces thermocouples: courbes d'etalonnage moyen, influence des chocs thermiques, temps de reponse, et alliages assurant la compensation de soudure froide. L'etude 'en-pile' a permis de rendre compte de l'evolution de ces thermocouples sous flux neutroniques. Les phenomenes observes ont conduit l'auteur a proposer un nouveau type de thermocouples constitues d'alliages molybdene-niobium. (auteur)

  4. Time-Separating Heating and Sensor Functions of Thermistors in Precision Thermal Control Applications

    Science.gov (United States)

    Cho, Hyung J.; Sukhatme, Kalyani G.; Mahoney, John C.; Penanen, Konstantin Penanen; Vargas, Rudolph, Jr.

    2010-01-01

    A method allows combining the functions of a heater and a thermometer in a single device, a thermistor, with minimal temperature read errors. Because thermistors typically have a much smaller thermal mass than the objects they monitor, the thermal time to equilibrate the thermometer to the temperature of the object is typically much shorter than the thermal time of the object to change its temperature in response to an external perturbation.

  5. Thermocouple modeling

    International Nuclear Information System (INIS)

    Fryer, M.O.

    1984-01-01

    The temperature measurements provided by thermocouples (TCs) are important for the operation of pressurized water reactors. During severe inadequate core cooling incidents, extreme temperatures may cause type K thermocouples (TCs) used for core exit temperature monitoring to perform poorly. A model of TC electrical behavior has been developed to determine how TCs react under extreme temperatures. The model predicts the voltage output of the TC and its impedance. A series of experiments were conducted on a length of type K thermocouple to validate the model. Impedance was measured at several temperatures between 22 0 C and 1100 0 C and at frequencies between dc and 10 MHz. The model was able to accurately predict impedance over this wide range of conditions. The average percentage difference between experimental data and the model was less than 6.5%. Experimental accuracy was +-2.5%. There is a sriking difference between impedance versus frequency plots at 300 0 C and at higher temperatures. This may be useful in validating TC data during accident conditions

  6. MEMS Flow Sensors Based on Self-Heated aGe-Thermistors in a Wheatstone Bridge

    Directory of Open Access Journals (Sweden)

    Almir Talic

    2015-04-01

    Full Text Available A thermal flow transduction method combining the advantages of calorimetric and hot-film transduction principles is developed and analyzed by Finite Element Method (FEM simulations and confirmed experimentally. The analyses include electrothermal feedback effects of current driven NTC thermistors. Four thin-film germanium thermistors acting simultaneously as heat sources and as temperature sensors are embedded in a micromachined silicon-nitride membrane. These devices form a self-heated Wheatstone bridge that is unbalanced by convective cooling. The voltage across the bridge and the total dissipated power are exploited as output quantities. The used thin-film thermistors feature an extremely high temperature sensitivity. Combined with properly designed resistance values, a power demand in sub-1mW range enables efficient gas-flow transduction, as confirmed by measurements. Two sensor configurations with different arrangements of the membrane thermistors were examined experimentally. Moreover, we investigated the influence of different layouts on the rise time, the sensitivity, and the usable flow range by means of two-dimensional finite element simulations. The simulation results are in reasonable agreement with corresponding measurement data confirming the basic assumptions and modeling approach.

  7. Fabrication and use of zircaloy/tantalum-sheathed cladding thermocouples and molybdenum/rhenium-sheathed fuel centerline thermocouples

    International Nuclear Information System (INIS)

    Wilkins, S.C.; Sepold, L.K.

    1985-01-01

    The thermocouples described in this report are zircaloy/tantalum-sheathed and molybdenum/rhenium alloy-sheathed instruments intended for fuel rod cladding and fuel centerline temperature measurements, respectively. Both types incorporate beryllium oxide insulation and tungsten/rhenium alloy thermoelements. These thermocouples, operated at temperatures of 2000 0 C and above, were developed for use in the internationally sponsored Severe Fuel Damage test series in the Power Burst Facility. The fabrication steps for both thermocouple types are described in detail. A laser-welding attachment technique for the cladding-type thermocouple is presented, and experience with alternate materials for cladding and fuel therocouples is discussed

  8. A Simple Experiment to Determine the Characteristics of an NTC Thermistor for Low-Temperature Measurement Applications

    Science.gov (United States)

    Mawire, A.

    2012-01-01

    A simple low-cost experiment for undergraduate students to determine the characteristics of a negative temperature coefficient of resistance thermistor is presented. The experiment measures the resistance-temperature and voltage-temperature characteristics of the thermistor. Results of the resistance-temperature experiment are used to determine…

  9. Adhesive-Bonded Tab Attaches Thermocouples to Titanium

    Science.gov (United States)

    Cook, C. F.

    1982-01-01

    Mechanical strength of titanium-alloy structures that support thermocouples is preserved by first spotwelding thermocouples to titanium tabs and then attaching tabs to titanium with a thermosetting adhesive. In contrast to spot welding, a technique previously used for thermocouples, fatigue strength of the titanium is unaffected by adhesive bonding. Technique is also gentler than soldering or attaching thermocouples with a tap screw.

  10. PWR thermocouple mechanical sealing structure

    International Nuclear Information System (INIS)

    Shen Qiuping; He Youguang

    1991-08-01

    The PWR in-core temperature detection device, which is one of measures to insure reactor safety operation, is to monitor and diagnose reactor thermal power output and in-core power distribution. The temperature detection device system uses thermocouples as measuring elements with stainless steel protecting sleeves. The thermocouple has a limited service time and should be replaced after its service time has reached. A new sealing device for the thermocouples of reactor in-core temperature detection system has been developed to facilitate replacement. The structure is complete tight under high temperature and pressure without any leakage and seepage, and easy to be assembled or disassembled in radioactive environment. The device is designed to make it possible to replace the thermocouple one by one if necessary. This is a new, simple and practical structure

  11. Flexible temperature and flow sensor from laser-induced graphene

    KAUST Repository

    Marengo, Marco

    2017-12-25

    Herein we present a flexible temperature sensor and a flow speed sensor based on laser-induced graphene. The main benefits arise from peculiar electrical, thermal and mechanical performances of the material thus obtained, along with a cheap and simple fabrication process. The temperature sensor is a negative temperature coefficient thermistor with non-linear response typical of semi-metals. The thermistor shows a 4% decrease of the resistance in a temperature range of 20–60 °C. The flow sensor exploits the piezoresistive properties of laser-induced graphene and can be used both in gaseous and liquid media thanks to a protective polydimethylsiloxane coating. Main characteristics are ultra-fast response and versatility in design offered by the laser technology.

  12. Process control of an ethanol fermentation with an enzyme thermistor as a sucrose sensor

    Energy Technology Data Exchange (ETDEWEB)

    Mandenius, C F; Danielsson, B; Mattiasson, B

    1981-01-01

    An enzyme thermistor was used to monitor and control the sucrose concentration in a conversion of sucrose to EtOH with immobilized yeast. A continuous stirred tank reactor containing Ca alginate-immobilized Saccharomyces cerevisiae was used. The enzyme thermistor continuously measured the sucrose concentration in the fermentor with an online arrangement giving stable and reproducible heat signals. The control of the sucrose concentration level was performed with an analog P1-controller.

  13. Thermistor based, low velocity isothermal, air flow sensor

    International Nuclear Information System (INIS)

    Cabrita, Admésio A C M; Mendes, Ricardo; Quintela, Divo A

    2016-01-01

    The semiconductor thermistor technology is applied as a flow sensor to measure low isothermal air velocities (<2 ms −1 ). The sensor is subjected to heating and cooling cycles controlled by a multifunctional timer. In the heating stage, the alternating current of a main AC power supply source guarantees a uniform thermistor temperature distribution. The conditioning circuit assures an adequate increase of the sensors temperature and avoids the thermal disturbance of the flow. The power supply interruption reduces the consumption from the source and extends the sensors life time. In the cooling stage, the resistance variation of the flow sensor is recorded by the measuring chain. The resistive sensor parameters proposed vary significantly and feature a high sensitivity to the flow velocity. With the aid of a computer, the data transfer, storage and analysis provides a great advantage over the traditional local anemometer readings. The data acquisition chain has a good repeatability and low standard uncertainties. The proposed method measures isothermal air mean velocities from 0.1 ms −1 to 2 ms −1 with a standard uncertainty error less than 4%. (paper)

  14. Conjugated polymer/graphene oxide nanocomposite as thermistor

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, Girish M., E-mail: varadgm@gmail.com; Deshmukh, Kalim [Polymer Nanocomposite Laboratory, Material Physics Division, School of Advanced Sciences, VIT University, Vellore - 632014, TN (India)

    2015-06-24

    We demonstrated the synthesis and measurement of temperature dependent electrical resistivity of graphene oxide (GO) reinforced poly (3, 4 - ethylenedioxythiophene) - tetramethacrylate (PEDOTTMA)/Polymethylmethacrylate (PMMA) based nanocomposites. Negative temperature coefficient (NTC) was observed for 0.5, 1 % GO loading and the positive temperature coefficient (PTC) was observed for 1.5 and 2 % Go loading in the temperature (40 to 120 °C). The GO inducted nanocomposite perform as an excellent thermistor and suitable for electronic and sensor domain.

  15. Conjugated polymer/graphene oxide nanocomposite as thermistor

    International Nuclear Information System (INIS)

    Joshi, Girish M.; Deshmukh, Kalim

    2015-01-01

    We demonstrated the synthesis and measurement of temperature dependent electrical resistivity of graphene oxide (GO) reinforced poly (3, 4 - ethylenedioxythiophene) - tetramethacrylate (PEDOTTMA)/Polymethylmethacrylate (PMMA) based nanocomposites. Negative temperature coefficient (NTC) was observed for 0.5, 1 % GO loading and the positive temperature coefficient (PTC) was observed for 1.5 and 2 % Go loading in the temperature (40 to 120 °C). The GO inducted nanocomposite perform as an excellent thermistor and suitable for electronic and sensor domain

  16. Low Drift Type N Thermocouples for Nuclear Applications

    International Nuclear Information System (INIS)

    Scervini, M.; Rae, C.

    2013-06-01

    Thermocouples are the most commonly used sensors for temperature measurement in nuclear reactors. They are crucial for the control of current nuclear reactors and for the development of GEN IV reactors. In nuclear applications thermocouples are strongly affected by intense neutron fluxes. As a result of the interaction with neutrons, the thermoelements of the thermocouples undergo transmutation, which produces a time dependent change in composition and, as a consequence, a time dependent drift of the thermocouple signal. Thermocouple drift can be very significant for in-pile temperature measurements and may render the temperature sensors unreliable after exposure to nuclear radiation for relatively short times compared to the life required for temperature sensors in nuclear applications. Previous experiences with type K thermocouples in nuclear reactors have shown that they are affected by neutron irradiation only to a limited extent. Similarly type N thermocouples are expected to be only slightly affected by neutron fluxes. Currently the use of Nickel based thermocouples is limited to temperatures lower than 1000 deg. C due to drift related to phenomena other than nuclear irradiation. In this work, undertaken as part of the European project METROFISSION, the drift of type N thermocouples has been investigated in the temperature range 600-1300 deg. C. The approach of this study is based on the attempt to separate the contributions of each thermo-element to drift. In order to identify the dominant thermo-element for drift, the contributions of both positive (NP) and negative (NN) thermo-elements to the total drift of 3.2 mm diameter MIMS thermocouples have been measured in each drift test using a pure Pt thermo-element as a reference. Conventional Inconel-600 sheathed type N thermocouples have been compared with type N thermocouples sheathed in a new alloy. At temperatures higher than 1000 deg. C conventional Inconel600 sheathed type N thermocouples can experience a

  17. Noncontacting Measurement With a Thermocouple

    Science.gov (United States)

    Weatherill, W. T.; Schoreder, C. J.; Freitag, H. J.

    1986-01-01

    Tentlike covering brings thermocouple to within few degrees of surface temperature. Technique originally developed for measuring surface temperature of quartz fabric under radiant heating requires no direct contact with heated surface. Technique particularly useful when measuring surface temperatures of materials damaged if thermocouple or other temperature sensor attached.

  18. Measurement of water flow rate in unsaturated soil by thermistor type sensor

    International Nuclear Information System (INIS)

    Takebe, Shinichi; Yamamoto, Tadatoshi; Wadachi, Yoshiki

    1981-09-01

    As a part of radiological safety studies for ground disposal of radioactive wastes, a measuring apparatus of water flow rate with thermistor type sensor was made as preliminary one and the measurement of water flow rate in the soil was carried out, in order to evalute by comparison of the migration rate of water with that of radionuclide in an unsaturated soil. The water flow rate can be determined by measuring the change of the thermal conductivity (temperature) of soil around the several thermistor type sensors set in a soil. Particularly at the region of low water content in the soil, the water flow rate was able to measure successfully by this apparatus. (author)

  19. LOFT small break test thermocouple installation

    International Nuclear Information System (INIS)

    Fors, R.M.

    1980-01-01

    The subject thermocouple design has been analyzed for maximum expected hydraulic loading and found to be adequate. The natural frequency of the thermocouple was found to be between the vortex shedding frequencies for the gas and liquid phase so that a tendency for resonance will exist. However, since the thermocouple support will have a restricted displacement, stresses found are below the endurance limit and, thus, are acceptable in respect to fatigue life as well as primary stress due to pressure loading

  20. Transmutation of Thermocouples in Thermal and Fast Nuclear Reactors

    International Nuclear Information System (INIS)

    Scervini, M.; Rae, C.; Lindley, B.

    2013-06-01

    Thermocouples are the most commonly used sensors for temperature measurement in nuclear reactors. Their role is fundamental for the control of current nuclear reactors and for the development of the nuclear technology needed for the implementation of GEN IV nuclear reactors. When used for in-core measurements thermocouples are strongly affected not only by high temperatures, but also by intense neutron fluxes. As a result of the interaction with neutrons, the thermoelements of the thermocouples undergo transmutation, which produces a time dependent change in composition in the thermoelements and, as a consequence, a time dependent drift in the thermocouple signal. Thermocouple drift can be very significant for in-pile temperature measurements and may render the temperature sensors unreliable after exposure to nuclear radiation for relatively short times compared to the life required for temperature sensors in nuclear applications. In this work, undertaken as part of the European project METROFISSION, the change in composition occurring in irradiated thermocouples has been calculated using the software ORIGEN 2.2. Several thermocouples have been considered, including Nickel based thermocouples (type K and type N), Tungsten based thermocouples (W-5%Re vs W-26%Re and W- 3%Re vs W-25%Re), Platinum based thermocouples (type S and Platinum vs Palladium) and Molybdenum vs Niobium thermocouples. The transmutation induced by both thermal flux and fast flux has been calculated. Thermocouples undergo more pronounced transmutation in thermal fluxes rather than in fast fluxes, as the neutron cross section of an element is higher for thermal energies. Nickel based thermocouples have a minimal change in composition, while Platinum based and Tungsten based thermocouples experience a very significant transmutation. The use of coatings deposited on the sheath of a thermocouple has been considered as a mean to reduce the neutron flux the thermoelements inside the thermocouple sheath

  1. Spatial filtring and thermocouple spatial filter

    International Nuclear Information System (INIS)

    Han Bing; Tong Yunxian

    1989-12-01

    The design and study on thermocouple spatial filter have been conducted for the flow measurement of integrated reactor coolant. The fundamental principle of spatial filtring, mathematical descriptions and analyses of thermocouple spatial filter are given

  2. Sputtered type s thermocouples on quartz glass substrates

    International Nuclear Information System (INIS)

    Sopko, B.; Vlk, J.; Chren, D.; Sopko, V.; Dammer, J.; Mengler, J.; Hynek, V.

    2011-01-01

    The work deals with the development of thin film thermocouples and their practical use. The principle of measuring planar thin film thermocouples is the same as for conventional thermocouples and is based on the thermoelectric effect, which named after its discoverer, Seebeck. Seebeck effect is direct conversion of temperature differences to electric voltage. In different applications it is necessary to use temperature sensors with high spatial resolution (with the placement of several measured points on the segment of length 1 mm) and short response time. For this application are currently used planar thermocouples with important advantage in production price and reproducible production. The innovative potential of thin-film thermocouples are to be found mainly in: 1 st use of technology in thin layers, unlike the already mature technologies applied in the production of conventional thermocouple probes are capable of further improvement with the usage of new substrate materials, modified methods for creating electrical contacts to the new thermocouple configuration and adhesive and protective layers, 2 nd in saving precious and rare metals, 3 rd decreasing the thickness of the layers and reducing the overall size of thermo probe. Measuring the temperature of molten steel, leading to a general loss of strength and the subsequent destruction of the probe. Here exhibited the highest resistance of quartz plates used in thin film substrates thermocouples. (authors)

  3. Embedded cladding surface thermocouples on Zircaloy-sheathed heater rods

    International Nuclear Information System (INIS)

    Wilkins, S.C.

    1977-06-01

    Titanium-sheathed Type K thermocouples embedded in the cladding wall of zircaloy-sheathed heater rods are described. These thermocouples constitute part of a program intended to characterize the uncertainty of measurements made by surface-mounted cladding thermocouples on nuclear fuel rods. Fabrication and installation detail, and laboratory testing of sample thermocouple installations are included

  4. Base metal thermocouples drift rate dependence from thermoelement diameter

    Science.gov (United States)

    Pavlasek, P.; Duris, S.; Palencar, R.

    2015-02-01

    Temperature measurements are one of the key factors in many industrial applications that directly affect the quality, effectiveness and safety of manufacturing processes. In many industrial applications these temperature measurements are realized by thermocouples. Accuracy of thermocouples directly affects the quality of the final product of manufacturing and their durability determines the safety margins required. One of the significant effects that affect the precision of the thermocouples is short and long term stability of their voltage output. This stability issue occurs in every type of thermocouples and is caused by multiple factors. In general these factors affect the Seebeck coefficient which is a material constant, which determines the level of generated voltage when exposed to a temperature gradient. Changes of this constant result in the change of the thermocouples voltage output thus indicated temperature which can result in production quality issues, safety and health hazards. These alternations can be caused by physical and chemical changes within the thermocouple lead material. Modification of this material constant can be of temporary nature or permanent. This paper concentrates on the permanent, or irreversible changes of the Seebeck coefficient that occur in commonly used swaged MIMS Type N thermocouples. These permanent changes can be seen as systematic change of the EMF of the thermocouple when it is exposed to a high temperature over a period of time. This change of EMF by time is commonly known as the drift of the thermocouple. This work deals with the time instability of thermocouples EMF at temperatures above 1200 °C. Instability of the output voltage was taken into relation with the lead diameter of the tested thermocouples. This paper concentrates in detail on the change of voltage output of thermocouples of different diameters which were tested at high temperatures for the overall period of more than 210 hours. The gather data from this

  5. Base metal thermocouples drift rate dependence from thermoelement diameter

    International Nuclear Information System (INIS)

    Pavlasek, P; Duris, S; Palencar, R

    2015-01-01

    Temperature measurements are one of the key factors in many industrial applications that directly affect the quality, effectiveness and safety of manufacturing processes. In many industrial applications these temperature measurements are realized by thermocouples. Accuracy of thermocouples directly affects the quality of the final product of manufacturing and their durability determines the safety margins required. One of the significant effects that affect the precision of the thermocouples is short and long term stability of their voltage output. This stability issue occurs in every type of thermocouples and is caused by multiple factors. In general these factors affect the Seebeck coefficient which is a material constant, which determines the level of generated voltage when exposed to a temperature gradient. Changes of this constant result in the change of the thermocouples voltage output thus indicated temperature which can result in production quality issues, safety and health hazards. These alternations can be caused by physical and chemical changes within the thermocouple lead material. Modification of this material constant can be of temporary nature or permanent. This paper concentrates on the permanent, or irreversible changes of the Seebeck coefficient that occur in commonly used swaged MIMS Type N thermocouples. These permanent changes can be seen as systematic change of the EMF of the thermocouple when it is exposed to a high temperature over a period of time. This change of EMF by time is commonly known as the drift of the thermocouple. This work deals with the time instability of thermocouples EMF at temperatures above 1200 °C. Instability of the output voltage was taken into relation with the lead diameter of the tested thermocouples. This paper concentrates in detail on the change of voltage output of thermocouples of different diameters which were tested at high temperatures for the overall period of more than 210 hours. The gather data from this

  6. Study of thermocouples for control of high temperatures

    International Nuclear Information System (INIS)

    Villamayor, M.

    1966-12-01

    Previous works have shown that the tungsten-rhenium alloys thermocouples were a good instrument for control of high temperatures. From its, the author has studied the W/W 26 per cent and W 5 per cent Re/W 26 per cent Re french manufactured thermocouples and intended for control of temperatures in nuclear reactors until 2300 deg. C. In 'out-pile' study he determines the general characteristics of these thermocouples: average calibration curves, thermal shocks influence, response times, and alloys allowing the cold source compensation. The evolution of these thermocouples under thermal neutron flux has been determined by 'in-pile' study. The observations have led the author to propose a new type of thermocouples settled of molybdenum-columbium alloys. (author) [fr

  7. Thermocouple evaluation model and evaluation of chromel--alumel thermocouples for High-Temperature Gas-Cooled Reactor applications

    International Nuclear Information System (INIS)

    Washburn, B.W.

    1977-03-01

    Factors affecting the performance and reliability of thermocouples for temperature measurements in High-Temperature Gas-Cooled Reactors are investigated. A model of an inhomogeneous thermocouple, associated experimental technique, and a method of predicting measurement errors are described. Error drifts for Type K materials are predicted and compared with published stability measurements. 60 references

  8. Zircaloy sheathed thermocouples for PWR fuel rod temperature measurements

    International Nuclear Information System (INIS)

    Anderson, J.V.; Wesley, R.D.; Wilkins, S.C.

    1979-01-01

    Small diameter zircaloy sheathed thermocouples have been developed by EG and G Idaho, Inc., at the Idaho National Engineering Laboratory. Surface mounted thermocouples were developed to measure the temperature of zircaloy clad fuel rods used in the Thermal Fuels Behavior Program (TFBP), and embedded thermocouples were developed for use by the Loss-of-Fluid Test (LOFT) Program for support tests using zircaloy clad electrically heated nuclear fuel rod simulators. The first objective of this developmental effort was to produce zircaloy sheathed thermocouples to replace titanium sheathed thermocouples and thereby eliminate the long-term corrosion of the titanium-to-zircaloy attachment weld. The second objective was to reduce the sheath diameter to obtain faster thermal response and minimize cladding temperature disturbance due to thermocouple attachment

  9. Operating problems of the thermocouples in VVER

    International Nuclear Information System (INIS)

    Timonin, A.S.

    1997-01-01

    In WWER reactors, the coolant temperature at the outlet of the majority of fuel assemblies is measured with chromel-alumel cable thermocouples. The components of systematic errors in temperature measurements are discussed. Errors due to calibration drift can be avoided by periodical calibrations performed during the heating and hot test runs after reactor refueling. Errors due to radiation heating and response time can be estimated and thus eliminated. Errors due to flow stratification of the coolant can also be eliminated by an estimation of correction factors. The effects of the aging of the thermocouples are also discussed. The removal of thermocouples from their coverings for replacement presents some difficulties, which thus determine the service life of the thermocouples. (A.K.)

  10. Thermocouple pressure bushing in suspension rod

    International Nuclear Information System (INIS)

    Pasek, J.; Ondreicka, K.

    1975-01-01

    The seal is described of jacket thermocouples located in the pressure reducer in the fuel element suspension rod. The thermocouples are sealed in the pressure reducer with a silicon sealing compound. The sealing compound is compressed between the two reducers with a Bellevile spring and a pressure washer secured in position with a spring. The axial pressure of the inner parts of the reducer on the compound is adjustable by means of a thrust screw. The tightness and alignment of the thermocouples in the pressure reducer is achieved by tightening the thrust screw to the stop of the top reducer and the subsequent setting of the sealing compound. (J.B.)

  11. Self-adapted thermocouple-diagnostic complex

    International Nuclear Information System (INIS)

    Alekseev, S.V.; Grankovskij, K.Eh.; Olejnikov, P.P.; Prijmak, S.V.; Shikalov, V.F.

    2003-01-01

    A self-adapted thermocouple-diagnostic complex (STDC) for obtaining the reliable data on the coolant temperature in the reactors of NPP is described. The STDC in based on the thermal pulse monitoring of a thermocouple in the measuring channel of a reactor. Measurement method and STDC composition are substantiated. It is shown that introduction of the developed STDC ensures realization of precise and reliable temperature monitoring in the reactors of all types [ru

  12. Geometrical and electrical properties of NTC polycrystalline thermistors vs. Changes of sintering parameters

    Directory of Open Access Journals (Sweden)

    Savić S.M.

    2006-01-01

    Full Text Available NTC thermistor powder was made of a Mn, Ni, Fe and Co oxide mixture calcinated at 1050°C / 60 min. The powder was milled in a ball mill down to an average particle diameter of 0.9 μm. Small disc shaped pills of the powder obtained were made by pressing with a pressure of 2.5 MPa. The pills were sintered in the temperature range of 900-1400 °C for 30-240 min. The volume and specific volume resistivity change were measured as a function of sintering conditions. Microstructure development was observed using a SEM microscope. Using the results obtained, optimization of sintering parameters was performed in order to determine optimal electrical properties of the selected thermistor composition.

  13. A comprehensive survey of thermoelectric homogeneity of commonly used thermocouple types

    Science.gov (United States)

    Machin, Jonathan; Tucker, Declan; Pearce, Jonathan V.

    2018-06-01

    Thermocouples are widely used as temperature sensors in industry. The electromotive force generated by a thermocouple is produced in a temperature gradient and not at the thermocouple tip. This means that the thermoelectric inhomogeneity represents one of the most important contributions to the overall measurement uncertainty associated with thermocouples. To characterise this effect, and to provide some general recommendations concerning the magnitude of this contribution to use when formulating uncertainty analyses, a comprehensive literature survey has been performed. Significant information was found for Types K, N, R, S, B, Pt/Pd, Au/Pt and various other Pt/Rh thermocouples. In the case of Type K and N thermocouples, the survey has been augmented by a substantial amount of data based on calibrations of mineral-insulated, metal-sheathed thermocouple cable reels from thermocouple manufacturers. Some general conclusions are drawn and outline recommendations given concerning typical values for the uncertainty arising from thermoelectric inhomogeneity for the most widely used thermocouple types in the as-new state. It is stressed that these recommendations should only be heeded when individual homogeneity measurements are not possible. It is also stressed that the homogeneity can deteriorate rapidly during use, particularly for base metal thermocouples.

  14. Construction and testing of a system for the electrical characterization of ceramic thermistors at low temperatures

    Directory of Open Access Journals (Sweden)

    F. C. S. Luz

    2014-03-01

    Full Text Available A high-precision and low cost system was built for the electrical characterization of ceramic thermistors at low temperatures, using components readily available in materials research laboratories. The system presented excellent reproducibility in the electrical characterization of NTC ceramic sensors from -75 ºC (195 K to 23 ºC (296 K. The behavior of the NTC sensor was comparable to that of commercial thermistors only below room temperature (α = -3.2%/K, demonstrating the importance of fully characterizing these materials at both low and high temperatures.

  15. A screen-printed flexible flow sensor

    International Nuclear Information System (INIS)

    Moschos, A; Kaltsas, G; Syrovy, T; Syrova, L

    2017-01-01

    A thermal flow sensor was printed on a flexible plastic substrate using exclusively screen-printing techniques. The presented device was implemented with custom made screen-printed thermistors, which allows simple, cost-efficient production on a variety of flexible substrates while maintaining the typical advantages of thermal flow sensors. Evaluation was performed for both static (zero flow) and dynamic conditions using a combination of electrical measurements and IR imaging techniques in order to determine important characteristics, such as temperature response, output repeatability, etc. The flow sensor was characterized utilizing the hot-wire and calorimetric principles of operation, while the preliminary results appear to be very promising, since the sensor was successfully evaluated and displayed adequate sensitivity in a relatively wide flow range. (paper)

  16. Characteristics of metal sheathed thermocouples in thermowell

    International Nuclear Information System (INIS)

    Okuda, Takehiro; Nakase, Tsuyoshi; Tanabe, Yutaka; Yamada, Kunitaka; Yoshizaki, Akio; Roko, Kiyokazu

    1987-01-01

    Static and dynamic characteristics of thermowell type thermocouples which are planned to be used for the High-Temperature engineering Test Reactor (HTTR) have been investigated. A mock-up test section was installed in Kawasaki's Helium Test Loop (KH-200). Thermal characteristics tests were carried out under the 600 ∼ 1000 deg C temperature conditions. The test section was equipped with four types sheathed thermocouples; the well type, the non well type, and ones with and without the thermal radiation shielding plate. The measured temperature by the well type thermocouples with the shielding plate was only about 1.3 deg C higher than the one without the shielding plate at gas temperature 990 deg C. The measured time constant of the well type thermocouples was about 7 seconds in the condition of the heat transfer coefficient 1600 Kcal/m 2 h deg C on the well surface, and coincided with the calculated one by ''TRUMP'' code. (author)

  17. A thermocouple thermometry system for ultrasound hyperthermia

    International Nuclear Information System (INIS)

    Ozarka, M.; Gharakhani, A.; Magin, R.; Cain, C.

    1984-01-01

    A thermometry system designed to be used in the treatment of cancer by ultrasound hyperthermia is described. The system monitors tumor temperatures using 16 type T (copper-constantan) thermocouples and is controlled by a 12 MHz Intel 8031 microcomputer. An analog circuit board contains the thermocouple amplifiers, an analog multiplexer, scaling circuitry, and an analog to digital converter. A digital board contains the Intel 8031, program memory, data memory, as well as circuitry for control and data communications. Communication with the hyperthermia system control computer is serially by RS-232 with selectable baud rate. Since the thermocouple amplifiers may have slight differences in gain and offset, a calibrated offset is added to a lookup table value to obtain the proper display temperature to within +- 0.1 0 C. The calibration routine, implemented in software, loads a nonvolatile random access memory chip with the proper offset values based on the outputs of each thermocouple channel at known temperatures which bracket a range of interest

  18. Estimation of radiation losses from sheathed thermocouples

    International Nuclear Information System (INIS)

    Roberts, I.L.; Coney, J.E.R.; Gibbs, B.M.

    2011-01-01

    Thermocouples are often used for temperature measurements in heat exchangers. However if the radiation losses from a thermocouple in a high temperature gas flow to colder surroundings are ignored significant errors can occur. Even at moderate temperature differences, these can be significant. Prediction of radiation losses from theory can be problematic, especially in situations where there are large variations in the measured temperatures as the emissivity and radiative heat transfer coefficient of the thermocouple are not constant. The following approach combines experimental results with established empirical relationships to estimate losses due to radiation in an annular heat exchanger at temperatures up to 950 o C. - Highlights: → Sheathed thermocouples are often used to measure temperatures in heat exchangers. → Errors are introduced if radiation losses are ignored. → Radiation losses are environment specific and may be significant. → Experimental and theoretical methods are used to estimate losses. → Hot side maximum temperature 950 o C.

  19. Metallic and Ceramic Thin Film Thermocouples for Gas Turbine Engines

    Directory of Open Access Journals (Sweden)

    Otto J. Gregory

    2013-11-01

    Full Text Available Temperatures of hot section components in today’s gas turbine engines reach as high as 1,500 °C, making in situ monitoring of the severe temperature gradients within the engine rather difficult. Therefore, there is a need to develop instrumentation (i.e., thermocouples and strain gauges for these turbine engines that can survive these harsh environments. Refractory metal and ceramic thin film thermocouples are well suited for this task since they have excellent chemical and electrical stability at high temperatures in oxidizing atmospheres, they are compatible with thermal barrier coatings commonly employed in today’s engines, they have greater sensitivity than conventional wire thermocouples, and they are non-invasive to combustion aerodynamics in the engine. Thin film thermocouples based on platinum:palladium and indium oxynitride:indium tin oxynitride as well as their oxide counterparts have been developed for this purpose and have proven to be more stable than conventional type-S and type-K thin film thermocouples. The metallic and ceramic thin film thermocouples described within this paper exhibited remarkable stability and drift rates similar to bulk (wire thermocouples.

  20. Flexible and foldable paper-substrate thermoelectric generator (teg)

    KAUST Repository

    Rojas, Jhonathan Prieto

    2017-08-24

    Flexible and foldable paper-substrate thermoelectric generators (TEGs) and methods for making the paper-substrate TEGs are disclosed. A method includes depositing a plurality of thermocouples in series on a paper substrate to create a paper-substrate TEG, wherein the plurality of thermocouples is deposited between two contact points of the paper-substrate TEG. The method may also include setting the power density and maximum achievable temperature gradient of the paper-substrate TEG by folding the paper-substrate TEG. A paper-substrate TEG apparatus may include a paper substrate and a plurality of thermocouples deposited in series on the paper substrate between two contact points of the paper-substrate TEG, wherein the power density and maximum achievable temperature gradient of the paper-substrate TEG is set by folding the paper-substrate TEG.

  1. Technological improvements to high temperature thermocouples for nuclear reactor applications

    International Nuclear Information System (INIS)

    Schley, R.; Leveque, J.P.

    1980-07-01

    The specific operating conditions of thermocouples in nuclear reactors have provided an incentive for further advances in high temperature thermocouple applications and performance. This work covers the manufacture and improvement of existing alloys, the technology of clad thermocouples, calibration drift during heat treatment, resistance to thermal shock and the compatibility of insulating materials with thermo-electric alloys. The results lead to specifying improved operating conditions for thermocouples in nuclear reactor media (pressurized water, sodium, uranium oxide) [fr

  2. Thin film platinum–palladium thermocouples for gas turbine engine applications

    Energy Technology Data Exchange (ETDEWEB)

    Tougas, Ian M.; Gregory, Otto J., E-mail: gregory@egr.uri.edu

    2013-07-31

    Thin film platinum:palladium thermocouples were fabricated on alumina and mullite surfaces using radio frequency sputtering and characterized after high temperature exposure to oxidizing environments. The thermoelectric output, hysteresis, and drift of these sensors were measured at temperatures up to 1100 °C. Auger electron spectroscopy was used to follow the extent of oxidation in each thermocouple leg and interdiffusion at the metallurgical junction. Minimal oxidation of the platinum and palladium thermoelements was observed after high temperature exposure, but considerable dewetting and faceting of the films were observed in scanning electron microscopy. An Arrhenius temperature dependence on the drift rate was observed and later attributed to microstructural changes during thermal cycling. The thin film thermocouples, however, did exhibit excellent stability at 1000 °C with drift rates comparable to commercial type-K wire thermocouples. Based on these results, platinum:palladium thin film thermocouples have considerable potential for use in the hot sections of gas turbine engines. - Highlights: • Stable thin film platinum:palladium thermocouples for gas turbine engines • Little oxidation but significant microstructural changes from thermal cycling • Minimal hysteresis during repeated thermal cycling • Drift comparable to commercial wire thermocouples.

  3. A method to eliminate the effect of radiation on thermocouple performance

    International Nuclear Information System (INIS)

    Ali, Fawaz; Lu Lixuan

    2007-01-01

    In-core temperature measurements are pivotal in maintaining nuclear reactors in a safe state of operation. Thermocouples serve as the liaison in ensuring this safe state. The realization of the thermocouple's full potential is hindered by the fact that thermocouples cannot be situated in areas with high radiation fields. Radiation has the potential of generating voltages in the thermocouple wires, hence producing an error in the temperature transmitter output. In this paper, a mathematical model is developed to quantify the effect that radiation from the Canada Deuterium Uranium (CANDU) Nuclear Power Plants (NPPs) has on the thermocouple temperature reading. Subsequently, a method to offset the effect of radiation on the thermocouple is proposed. Simulation is performed to verify the effectiveness of the proposed system

  4. Effects of thermocouple installation and location on fuel rod temperature measurements

    International Nuclear Information System (INIS)

    McCormick, R.D.

    1983-01-01

    This paper describes the results of analyses of nuclear fuel rod cladding temperature data obtained during in-reactor experiments under steady state and transient (simulated loss-of-coolant accident) operating conditions. The objective of the analyses was to determine the effect of thermocouple attachment method and location on measured thermal response. The use of external thermocouples increased the time to critical heat flux (CHF), reduced the blowdown peak temperature, and enhanced rod quench. A comparison of laser welded and resistance welded external thermocouple responses showed that the laser welding technique reduced the indicated cladding steady state temperatures and provided shorter time-to-CHF. A comparison of internal welded and embedded thermocouples indicated that the welded technique gave generally unsatisfactory cladding temperature measurements. The embedded thermocouple gave good, consistent results, but was possibly more fragile than the welded thermocouples. Detailed descriptions of the thermocouple designs, attachment methods and locations, and test conditions are provided

  5. The development of a fast response thermocouple for use in liquid metals

    International Nuclear Information System (INIS)

    Morss, A.G.; Vincent, B.

    1987-03-01

    Work carried out at Berkeley Nuclear Laboratories to develop a fast-response thermocouple for use in liquid metals is described. This thermocouple because of its unique construction, has a junction mass approaching zero and hence its frequency response should be very high. Some of the problems of manufacture are discussed, in particular the high quality of seal required to avoid ingress of liquid metal. A comparison of results obtained with the fast-response thermocouple and with conventional stainless-steel-sheathed thermocouples is made. The improved response of the new thermocouple is clearly visible, hence confirming that measurements made with sheathed thermocouples suffer attenuation. It is concluded that results obtained with the fast-response thermocouple are close to the real magnitude of temperature fluctuations present in turbulent flow. It is also demonstrated that, with suitable corrections, results obtained with sheathed thermocouples can be used to estimate the real signals present in the flow. (author)

  6. Summary of Thermocouple Performance During Advanced Gas Reactor Fuel Irradiation Experiments in the Advanced Test Reactor and Out-of-Pile Thermocouple Testing in Support of Such Experiments

    Energy Technology Data Exchange (ETDEWEB)

    A. J. Palmer; DC Haggard; J. W. Herter; M. Scervini; W. D. Swank; D. L. Knudson; R. S. Cherry

    2011-07-01

    High temperature gas reactor experiments create unique challenges for thermocouple based temperature measurements. As a result of the interaction with neutrons, the thermoelements of the thermocouples undergo transmutation, which produces a time dependent change in composition and, as a consequence, a time dependent drift of the thermocouple signal. This drift is particularly severe for high temperature platinum-rhodium thermocouples (Types S, R, and B); and tungsten-rhenium thermocouples (Types C and W). For lower temperature applications, previous experiences with type K thermocouples in nuclear reactors have shown that they are affected by neutron irradiation only to a limited extent. Similarly type N thermocouples are expected to be only slightly affected by neutron fluxes. Currently the use of these Nickel based thermocouples is limited when the temperature exceeds 1000°C due to drift related to phenomena other than nuclear irradiation. High rates of open-circuit failure are also typical. Over the past ten years, three long-term Advanced Gas Reactor (AGR) experiments have been conducted with measured temperatures ranging from 700oC – 1200oC. A variety of standard Type N and specialty thermocouple designs have been used in these experiments with mixed results. A brief summary of thermocouple performance in these experiments is provided. Most recently, out of pile testing has been conducted on a variety of Type N thermocouple designs at the following (nominal) temperatures and durations: 1150oC and 1200oC for 2000 hours at each temperature, followed by 200 hours at 1250oC, and 200 hours at 1300oC. The standard Type N design utilizes high purity crushed MgO insulation and an Inconel 600 sheath. Several variations on the standard Type N design were tested, including Haynes 214 alloy sheath, spinel (MgAl2O4) insulation instead of MgO, a customized sheath developed at the University of Cambridge, and finally a loose assembly thermocouple with hard fired alumina

  7. Summary of thermocouple performance during advanced gas reactor fuel irradiation experiments in the advanced test reactor and out-of-pile thermocouple testing in support of such experiments

    Energy Technology Data Exchange (ETDEWEB)

    Palmer, A. J.; Haggard, DC; Herter, J. W.; Swank, W. D.; Knudson, D. L.; Cherry, R. S. [Idaho National Laboratory, P.O. Box 1625, MS 4112, Idaho Falls, ID, (United States); Scervini, M. [University of Cambridge, Department of Material Science and Metallurgy, 27 Charles Babbage Road, CB3 0FS, Cambridge, (United Kingdom)

    2015-07-01

    High temperature gas reactor experiments create unique challenges for thermocouple-based temperature measurements. As a result of the interaction with neutrons, the thermoelements of the thermocouples undergo transmutation, which produces a time-dependent change in composition and, as a consequence, a time-dependent drift of the thermocouple signal. This drift is particularly severe for high temperature platinum-rhodium thermocouples (Types S, R, and B) and tungsten-rhenium thermocouples (Type C). For lower temperature applications, previous experiences with Type K thermocouples in nuclear reactors have shown that they are affected by neutron irradiation only to a limited extent. Similarly, Type N thermocouples are expected to be only slightly affected by neutron fluence. Currently, the use of these nickel-based thermocouples is limited when the temperature exceeds 1000 deg. C due to drift related to phenomena other than nuclear irradiation. High rates of open-circuit failure are also typical. Over the past 10 years, three long-term Advanced Gas Reactor experiments have been conducted with measured temperatures ranging from 700 deg. C - 1200 deg. C. A variety of standard Type N and specialty thermocouple designs have been used in these experiments with mixed results. A brief summary of thermocouple performance in these experiments is provided. Most recently, out-of-pile testing has been conducted on a variety of Type N thermocouple designs at the following (nominal) temperatures and durations: 1150 deg. C and 1200 deg. C for 2,000 hours at each temperature, followed by 200 hours at 1250 deg. C and 200 hours at 1300 deg. C. The standard Type N design utilizes high purity, crushed MgO insulation and an Inconel 600 sheath. Several variations on the standard Type N design were tested, including a Haynes 214 alloy sheath, spinel (MgAl{sub 2}O{sub 4}) insulation instead of MgO, a customized sheath developed at the University of Cambridge, and finally a loose assembly

  8. Thermocouple correlation transit time flowmeter tests at WCL

    International Nuclear Information System (INIS)

    Lassahn, G.D.

    1976-11-01

    Scoping tests indicate the feasibility for using transit time flowmeters with thermocouple sensors in steam-water steady state flow. Conclusive results were not obtained. More conclusive results are expected from tests to be conducted in the semiscale facility with a redesigned transit time thermocouple sensor

  9. Zircaloy-sheathed element rods fitted with thermo-couples; Barre combustible a thermocouple gainee de zircaloy

    Energy Technology Data Exchange (ETDEWEB)

    Bernardy de Sigoyer, B; Jacques, F; Thome, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-07-01

    In order to carry out thermal conductivity measurements on UO{sub 2} in conditions similar to those under which fuel rods are used, it was necessary to measure the temperature at the interior of a fuel element sheathed in zircaloy. The temperatures are taken with Thermocoax type thermocouples, that is to say fitted with a very thin sheath of stainless steel or Inconel. It is known also that fusion welding of zircaloy onto stainless steel is impossible and that high temperature welded joints are very difficult because of their aggressiveness. The technique used consists in brazing the thermocouples to relatively large stainless steel parts and then joining these plugs by electron bombardment welding to diffused stainless steel-zircaloy couplings. The properties of these diffused couplings and of the brazed joints were studied; the various stages in the fabrication of the containers are also described. (authors) [French] Pour des mesures de conductivite thermique de l'UO{sub 2} dans des conditions voisines du fonctionnement des barres combustibles, il s'agissait de mesurer la temperature a l'interieur d'un element combustible gaine de zircaloy. Les prises de temperature sont faites par thermocouples du type Thermocoax, c'est-a-dire pourvu d'une gaine tres mince en inox ou inconel. Par ailleurs on sait que le soudage par fusion du zircaloy sur l'inox est impossible et que les brasures a haute temperature sont difficiles car tres agressives. La technique utilisee consiste a braser les thermocouples sur des pieces en inox relativement massives et de rapporter par soudage au bombardement electronique ces bouchons sur des raccords diffuses zircaloy-inox. Les proprietes de ces raccords diffuses et celles de joints brases ont ete etudiees; on expose egalement les diverses etapes de fabrication des containers. (auteurs)

  10. Relative humidity measurements with thermocouple psychrometer and capacitance sensors

    International Nuclear Information System (INIS)

    Mao, Naihsien.

    1991-01-01

    The relative humidity is one of the important hydrological parameters affecting waste package performance. Water potential of a system is defined as the amount of work required to reversibly and isothermally move an infinitesimal quantity of water from a pool of pure water to that system at the same elevation. The thermocouple psychrometer, which acts as a wet-dry bulb instrument based on the Peltier effect, is used to measure water potential. The thermocouple psychrometer works only for relative humidity greater than 94 percent. Other sensors must be used for drier conditions. Hence, the author also uses a Vaisala Humicap, which measures the capacitance change due to relative humidity change. The operation range of the Humicap (Model HMP 135Y) is from 0 to 100 percent relative humidity and up to 160C (320F) in temperature. A psychrometer has three thermocouple junctions. Two copper-constantan junctions serve as reference temperature junctions and the constantan-chromel junction is the sensing junction. Current is passed through the thermocouple causing cooling of the sensing junction by the Peltier effect. When the temperature of the junction is below the dew point, water will condense upon the junction from the air. The Peltier current is discontinued and the thermocouple output is recorded as the temperature of the thermocouple returns to ambient. The temperature changes rapidly toward the ambient temperature until it reaches the wet bulb depression temperature. At this point, evaporation of the water from the junction produces a cooling effect upon the junction that offsets the heat absorbed from the ambient surroundings. This continues until the water is depleted and the thermocouple temperature returns to the ambient temperature (Briscoe, 1984). The datalogger starts to take data roughly at the wet bulb depression temperature

  11. Thermocouple design for measuring temperatures of small insects

    Science.gov (United States)

    A.A. Hanson; R.C. Venette

    2013-01-01

    Contact thermocouples often are used to measure surface body temperature changes of insects during cold exposure. However, small temperature changes of minute insects can be difficult to detect, particularly during the measurement of supercooling points. We developed two thermocouple designs, which use 0.51 mm diameter or 0.127 mm diameter copper-constantan wires, to...

  12. Realization of Copper Melting Point for Thermocouple Calibrations

    Directory of Open Access Journals (Sweden)

    Y. A. ABDELAZIZ

    2011-08-01

    Full Text Available Although the temperature stability and uncertainty of the freezing plateau is better than that of the melting plateau in most of the thermometry fixed points, but realization of melting plateaus are easier than that of freezing plateaus for metal fixed points. It will be convenient if the melting points can be used instead of the freezing points in calibration of standard noble metal thermocouples because of easier realization and longer plateau duration of melting plateaus. In this work a comparison between the melting and freezing points of copper (Cu was carried out using standard noble metal thermocouples. Platinum - platinum 10 % rhodium (type S, platinum – 30 % rhodium / platinum 6 % rhodium (type B and platinum - palladium (Pt/Pd thermocouples are used in this study. Uncertainty budget analysis of the melting points and freezing points is presented. The experimental results show that it is possible to replace the freezing point with the melting point of copper cell in the calibration of standard noble metal thermocouples in secondary-level laboratories if the optimal methods of realization of melting points are used.

  13. Investigation of electrical noise in selenium-immersed thermistor bolometers

    Science.gov (United States)

    Tarpley, J. L.; Sarmiento, P. D.

    1980-01-01

    The selenium immersed, thermistor bolometer, IR detector failed due to spurious and escalating electrical noise outburst as a function of time at elevated temperatures during routine ground based testing in a space simulated environment. Spectrographic analysis of failed bolometers revealed selenium pure zones in the insulating selenium arsenic (Se-As) glass film which surrounds the active sintered Mn, Ni, Co oxide flake. The selenium pure film was identified as a potentially serious failure mechanism. Significant changes were instituted in the manufacturing techniques along with more stringent process controls which eliminated the selenium pure film and successfully produced 22study bolometers.

  14. Long duration performance of high temperature irradiation resistant thermocouples

    International Nuclear Information System (INIS)

    Rempe, J.; Knudson, D.; Condie, K.; Cole, J.; Wilkins, S.C.

    2007-01-01

    Many advanced nuclear reactor designs require new fuel, cladding, and structural materials. Data are needed to characterize the performance of these new materials in high temperature, radiation conditions. However, traditional methods for measuring temperature in-pile degrade at temperatures above 1100 C degrees. To address this instrumentation need, the Idaho National Laboratory (INL) developed and evaluated the performance of a high temperature irradiation-resistant thermocouple that contains alloys of molybdenum and niobium. To verify the performance of INL's recommended thermocouple design, a series of high temperature (from 1200 to 1800 C) long duration (up to six months) tests has been initiated. This paper summarizes results from the tests that have been completed. Data are presented from 4000 hour tests conducted at 1200 and 1400 C that demonstrate the stability of this thermocouple (less than 2% drift). In addition, post test metallographic examinations are discussed which confirm the compatibility of thermocouple materials throughout these long duration, high temperature tests. (authors)

  15. Studies of Behavior Melting Temperature Characteristics for Multi Thermocouple In-Core Instrument Assembly

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Donghyup; Chae, Myoungeun; Kim, Sungjin; Lee, Kyulim [Woojin inc, Hwasung (Korea, Republic of)

    2015-05-15

    Bottom-up type in-core instruments (ICIs) are used for the pressurized water reactors of OPR-1000, APR- 1400 in order to measure neutron flux and temperature in the reactor. It is a well-known technique and a proven design using years in the nuclear field. ICI consists of one pair of K-type thermocouple, five self-powered neutron detectors (SPNDs) and one back ground detector. K-type thermocouple's purpose is to measure the core exit temperature (CET) in the reactor. The CET is a very important factor for operating nuclear power plants and it is 327 .deg. C when generally operating the reactor in the nuclear power plant(NPP) in case of OPR- 1000. If the CET will exceed 650 .deg. C, Operators in the main control room should be considered to be an accident situation in accordance with a severe accident management guidance(SAMG). The Multi Thermocouple ICI is a new designed ICI assuming severe accident conditions. It consists of four more thermocouples than the existing design, so it has five Ktype thermocouples besides the thermocouple measuring CET is located in the same elevation as the ICI. Each thermocouple is able to be located in the desired location as required. The Multi Thermocouple ICI helps to measure the temperature distribution of the entire reactor. In addition, it will measure certain point of melted core because of the in-vessel debris of nuclear fuel when an accident occurs more seriously. In this paper, to simulate a circumstance such as a nuclear reactor severe accident was examined. In this study, the K-type thermocouples of Multi Thermocouple ICI was confirmed experimentally to be able to measure up to 1370 .deg. C before the thermocouples have been melted. And after the thermocouples were melted by debris, it was able to be monitored that the signal of EMF directed the infinite value of voltage. Therefore through the results of the test, it can be assumed that if any EMF data among the Multi Thermocouple ICI will direct the infinite value

  16. Studies of Behavior Melting Temperature Characteristics for Multi Thermocouple In-Core Instrument Assembly

    International Nuclear Information System (INIS)

    Shin, Donghyup; Chae, Myoungeun; Kim, Sungjin; Lee, Kyulim

    2015-01-01

    Bottom-up type in-core instruments (ICIs) are used for the pressurized water reactors of OPR-1000, APR- 1400 in order to measure neutron flux and temperature in the reactor. It is a well-known technique and a proven design using years in the nuclear field. ICI consists of one pair of K-type thermocouple, five self-powered neutron detectors (SPNDs) and one back ground detector. K-type thermocouple's purpose is to measure the core exit temperature (CET) in the reactor. The CET is a very important factor for operating nuclear power plants and it is 327 .deg. C when generally operating the reactor in the nuclear power plant(NPP) in case of OPR- 1000. If the CET will exceed 650 .deg. C, Operators in the main control room should be considered to be an accident situation in accordance with a severe accident management guidance(SAMG). The Multi Thermocouple ICI is a new designed ICI assuming severe accident conditions. It consists of four more thermocouples than the existing design, so it has five Ktype thermocouples besides the thermocouple measuring CET is located in the same elevation as the ICI. Each thermocouple is able to be located in the desired location as required. The Multi Thermocouple ICI helps to measure the temperature distribution of the entire reactor. In addition, it will measure certain point of melted core because of the in-vessel debris of nuclear fuel when an accident occurs more seriously. In this paper, to simulate a circumstance such as a nuclear reactor severe accident was examined. In this study, the K-type thermocouples of Multi Thermocouple ICI was confirmed experimentally to be able to measure up to 1370 .deg. C before the thermocouples have been melted. And after the thermocouples were melted by debris, it was able to be monitored that the signal of EMF directed the infinite value of voltage. Therefore through the results of the test, it can be assumed that if any EMF data among the Multi Thermocouple ICI will direct the infinite value

  17. Heat penetration and thermocouple location in home canning.

    Science.gov (United States)

    Etzel, Mark R; Willmore, Paola; Ingham, Barbara H

    2015-01-01

    We processed applesauce, tomato juice, and cranberries in pint jars in a boiling water canner to test thermal processing theories against home canning of high-acid foods. For each product, thermocouples were placed at various heights in the jar. Values for f h (heating), f cl (cooling), and F 82.2°C (lethality) were determined for each thermocouple location, and did not depend substantially on thermocouple location in accordance with heat transfer theory. There was a cold spot in the jar, but the cold spot during heating became the hot spot during cooling. During heating, the geometric center was the last to heat, and remained coldest the longest, but during coooling, it was also the last to cool, and remained hottest the longest. The net effect was that calculated lethality in home canning was not affected by thermocouple location. Most of the lethality during home canning occurred during air cooling, making cooling of home canned foods of great importance. Calculated lethality was far greater than the required 5-log reduction of spores in tomato juice and vegetative cells in cranberries, suggesting a wide margin of safety for approved home-canning processes for high-acid foods.

  18. Temperature measurements by thermocouples

    International Nuclear Information System (INIS)

    Liermann, J.

    1975-01-01

    The measurement of a temperature (whatever the type of transducer used) raises three problems: the choice of transducer; where it should be placed; how it should be fixed and protected. These are the three main points examined, after a brief description of the most commonly used thermocouples [fr

  19. A Study of the Behavior Characteristics for K-type Thermocouple

    International Nuclear Information System (INIS)

    Ye, Songhae; Kim, Yongsik; Lee, Sooill; Kim, Sungjin; Lyou, Jooon

    2014-01-01

    K-type thermocouple is widely used in nuclear power plants (NPP) and they provide reliable service. Generally, the thermocouple assembly is the finished product and usually only nondestructive tests are performed on the assembly, whereas destructive tests are confined to selected bulk cable specimens. This K-type thermocouple has been used representatively in the In-Core Instrument Assembly (ICI) in the nuclear power plants. The ICI consists of five rhodium emitter detectors that provide information on the thermal power for the core and one K-type thermocouple made with two cables (Chromel-Alumel) that provides the temperature of core exit (CET). Generally, the quantity of the ICI is absolutely different according to the number of fuel assemblies in the NPP. In the case of SKN 3 and 4, they were designed to the 61 ICI to provide information on the core cooling to the inadequate core cooling monitoring system (ICCMS). This measured temperature could be also used to check the entry condition of severe accidents. The technology of the TFDR is a generic skill to detect the fault position of the cable. In-core Instruments (ICIs) were used to detect the Core Exit Temperature (CET) in a reactor. This measured temperature was also used to check the entry condition of severe accidents. However, if a serious accident occurs, the upper portion of the core is damaged. This instrument has not been available. This paper illustrates the estimation possibility for the status of molten core through the high-temperature characteristics test of k-type thermocouple. It turns out that it is possible to measure the k-type thermocouple up to 1350 .deg. C degrees before melting during insertion into the melting furnace. Additionally, in order to measure a high temperature of 2000 .deg. C or more, the replacement possibility of k-type thermocouple was evaluated. However the tungsten-rhenium thermocouple is impossible to use in the detection of temperature at the in-core because of the

  20. Stability Studies of a New Design Au/Pt Thermocouple Without a Strain Relieving Coil

    Science.gov (United States)

    Jahan, Ferdouse; Ballico, Mark

    2007-12-01

    The performance of a simple, new design Au/Pt thermocouple developed by NMIA is assessed. This thermocouple is proposed as a more accurate replacement, over the temperature range from 0 to 1,000°C, for the commonly used Type R and S industrial transfer standards, in a robust form familiar to industrial calibration laboratories. Due to the significantly different thermal expansions of the Au and Pt thermoelements, reported designs of the Au/Pt thermocouple incorporate a strain-relieving coil or bridge at the thermocouple junction. As the strain relieving coil is mechanically delicate, these thermocouples are usually mounted in a protective quartz tube assembly, like a standard platinum resistance thermometer (SPRT). Although providing uncertainties at the mK level, they are more delicate than the commonly used Type R and S thermocouples. A new and simple design of the Au/Pt thermocouple was developed in which the differential thermal expansion between Au and Pt is accommodated in the thermocouple leads, facilitated by a special head design. The resulting thermocouple has the appearance and robustness of the traditional Type R and S thermocouples, while retaining stability better than 10 mK up to 961°C. Three thermocouples of this design were calibrated at fixed points and by comparison to SPRTs in a stirred salt bath. In order to assess possible impurity migration, strain effects, and mechanical robustness, sequences of heat treatment up to a total of 500 h together with over 50 thermal cycles from 900°C to ambient were performed. The effect of these treatments on the calibration was assessed, demonstrating the sensors to be robust and stable to better than 10 mK. The effects on the measured inhomogeneity of the thermocouple were assessed using the NMIA thermocouple scanning bath.

  1. Contact Thermocouple Methodology and Evaluation for Temperature Measurement in the Laboratory

    Science.gov (United States)

    Brewer, Ethan J.; Pawlik, Ralph J.; Krause, David L.

    2013-01-01

    Laboratory testing of advanced aerospace components very often requires highly accurate temperature measurement and control devices, as well as methods to precisely analyze and predict the performance of such components. Analysis of test articles depends on accurate measurements of temperature across the specimen. Where possible, this task is accomplished using many thermocouples welded directly to the test specimen, which can produce results with great precision. However, it is known that thermocouple spot welds can initiate deleterious cracks in some materials, prohibiting the use of welded thermocouples. Such is the case for the nickel-based superalloy MarM-247, which is used in the high temperature, high pressure heater heads for the Advanced Stirling Converter component of the Advanced Stirling Radioisotope Generator space power system. To overcome this limitation, a method was developed that uses small diameter contact thermocouples to measure the temperature of heater head test articles with the same level of accuracy as welded thermocouples. This paper includes a brief introduction and a background describing the circumstances that compelled the development of the contact thermocouple measurement method. Next, the paper describes studies performed on contact thermocouple readings to determine the accuracy of results. It continues on to describe in detail the developed measurement method and the evaluation of results produced. A further study that evaluates the performance of different measurement output devices is also described. Finally, a brief conclusion and summary of results is provided.

  2. In-situ thermoelectric temperature monitoring and "Closed-loop integrated control" system for concentrator photovoltaic-thermoelectric hybrid receivers

    Science.gov (United States)

    Rolley, Matthew H.; Sweet, Tracy K. N.; Min, Gao

    2017-09-01

    This work demonstrates a new technique that capitalizes on the inherent flexibility of the thermoelectric module to provide a multifunctional platform, and exhibits a unique advantage only available within CPV-TE hybrid architectures. This system is the first to use the thermoelectric itself for hot-side temperature feedback to a PID control system, needing no additional thermocouple or thermistor to be attached to the cell - eliminating shading, and complex mechanical designs for mounting. Temperature measurement accuracy and thermoelectric active cooling functionality is preserved. Dynamic "per-cell" condition monitoring and protection is feasible using this technique, with direct cell-specific temperature measurement accurate to 1°C demonstrated over the entire experimental range. The extrapolation accuracy potential of the technique was also evaluated.

  3. Thermocouples for conditions of aggressive environments

    International Nuclear Information System (INIS)

    Blanc, J.Y.

    1988-01-01

    Two new kinds of thermocouples have been chosen for temperature measurements in the in-pile safety program for light water reactors performed in France. They must give fuel centerline or roc cladding temperatures and withstand steam oxidation between 1000 0 C and 1800 0 C or higher, under severe fuel damage conditions. We describe briefly both types, then we emphasize on improvements under way concerning the tungsten-rhenium legs, the hafnia insulation and the sheaths materials. Oxidation resistance is achieved mainly by silicides layers, but other possibilities are considered, such as iridium coatings. Some details of insulators manufacturing or sensor assembly are given, as well as other high temperature applications for these thermocouples

  4. Characterization of a Method for Inverse Heat Conduction Using Real and Simulated Thermocouple Data

    Science.gov (United States)

    Pizzo, Michelle E.; Glass, David E.

    2017-01-01

    It is often impractical to instrument the external surface of high-speed vehicles due to the aerothermodynamic heating. Temperatures can instead be measured internal to the structure using embedded thermocouples, and direct and inverse methods can then be used to estimate temperature and heat flux on the external surface. Two thermocouples embedded at different depths are required to solve direct and inverse problems, and filtering schemes are used to reduce noise in the measured data. Accuracy in the estimated surface temperature and heat flux is dependent on several factors. Factors include the thermocouple location through the thickness of a material, the sensitivity of the surface solution to the error in the specified location of the embedded thermocouples, and the sensitivity to the error in thermocouple data. The effect of these factors on solution accuracy is studied using the methodology discussed in the work of Pizzo, et. al.1 A numerical study is performed to determine if there is an optimal depth at which to embed one thermocouple through the thickness of a material assuming that a second thermocouple is installed on the back face. Solution accuracy will be discussed for a range of embedded thermocouple depths. Moreover, the sensitivity of the surface solution to (a) the error in the specified location of the embedded thermocouple and to (b) the error in the thermocouple data are quantified using numerical simulation, and the results are discussed.

  5. The use of thermocouples which transmute during service in nuclear reactors

    International Nuclear Information System (INIS)

    Martin, R.E.

    1980-06-01

    Some current nuclear fuel experiments at CRNL require the use of thermocouples to measure temperatures of up to 2200 0 C under reactor operating conditions. A literature search has shown that transient electrical effects and transmutation of the thermocouple alloys can cause temperature measurement errors of up to +-1% and +-30%, respectively. However, the error due to transient electrical effects can be corrected by making temperature measurements immediately following reactor shutdown. Furthermore it has been shown that transmutation effects can be corrected for by calibrating the high temperature tungsten-rhenium thermocouples against a chromel-alumel thermocouple in a cooler part of the experiment. The use of these techniques is expected to reduce temperature measurement errors to +-2% in the best case. (auth)

  6. A capacitive rf power sensor based on mems technology

    NARCIS (Netherlands)

    Fernandez, L.J.

    2005-01-01

    Existing power sensors for RF signals are based on thermistors, diodes and thermocouples. These power sensors are used as terminating devices and therefore they dissipate the complete incoming signal. Furthermore, new telecommunication systems require low weight, volume and power consumption and a

  7. Development of a micro-thermal flow sensor with thin-film thermocouples

    Science.gov (United States)

    Kim, Tae Hoon; Kim, Sung Jin

    2006-11-01

    A micro-thermal flow sensor is developed using thin-film thermocouples as temperature sensors. A micro-thermal flow sensor consists of a heater and thin-film thermocouples which are deposited on a quartz wafer using stainless steel masks. Thin-film thermocouples are made of standard K-type thermocouple materials. The mass flow rate is measured by detecting the temperature difference of the thin-film thermocouples located in the upstream and downstream sections relative to a heater. The performance of the micro-thermal flow sensor is experimentally evaluated. In addition, a numerical model is presented and verified by experimental results. The effects of mass flow rate, input power, and position of temperature sensors on the performance of the micro-thermal flow sensor are experimentally investigated. At low values, the mass flow rate varies linearly with the temperature difference. The linearity of the micro-thermal flow sensor is shown to be independent of the input power. Finally, the position of the temperature sensors is shown to affect both the sensitivity and the linearity of the micro-thermal flow sensor.

  8. Blind system identification of two-thermocouple sensor based on cross-relation method

    Science.gov (United States)

    Li, Yanfeng; Zhang, Zhijie; Hao, Xiaojian

    2018-03-01

    In dynamic temperature measurement, the dynamic characteristics of the sensor affect the accuracy of the measurement results. Thermocouples are widely used for temperature measurement in harsh conditions due to their low cost, robustness, and reliability, but because of the presence of the thermal inertia, there is a dynamic error in the dynamic temperature measurement. In order to eliminate the dynamic error, two-thermocouple sensor was used to measure dynamic gas temperature in constant velocity flow environments in this paper. Blind system identification of two-thermocouple sensor based on a cross-relation method was carried out. Particle swarm optimization algorithm was used to estimate time constants of two thermocouples and compared with the grid based search method. The method was validated on the experimental equipment built by using high temperature furnace, and the input dynamic temperature was reconstructed by using the output data of the thermocouple with small time constant.

  9. Mineral insulated thermocouples - installation in steam generating plant

    International Nuclear Information System (INIS)

    Bridges, W.J.; Brown, J.F.

    1980-01-01

    The main areas of interest considered are Central Station Fossil Fuel fired boilers of around 500 MW capacity, AGR Boilers, and Industrial and Research Development projects. While the requirement for temperature measurement in each of these areas may vary the techniques adopted to overcome installation and protection problems created by thermal, chemical and mechanical hazards remain basically the same. The reasons for temperature measurement are described together with methods of attachment development and procedures for protection of the thermocouple along its route length until its exit from the hazardous environment. These relative accuracies of the different attachments are discussed along with factors influencing the life of the thermocouple. In many instances thermocouple installation is either a once only opportunity and/or an expensive exercise. It is therefore essential to develop and apply an effective quality control system during the installation phase. An effective system is described. Finally, a brief outline of possible future trends is given. (author)

  10. DESEMPENHO DE DIFERENTES BITOLAS DE TERMOPAR EM UM PSICRÔMETRO ASPIRADO DE BAIXO CUSTO

    Directory of Open Access Journals (Sweden)

    CLÁUDIO RICARDO DA SILVA

    2011-01-01

    Full Text Available The objective of this work was to evaluate an aspirated psychrometer constructed under different thermocouple gauges. Were used three thermocouple copper-constantan gauge: 24 AWG (0.511 mm of diameter, 32 AWG (0.202 mm of diameter and 40 AWG (0.080 mm of diameter. The thermocouples were placed into a single psychrometer and each one positioned side by side at a distance of approximately 30 mm each other. Hourly air temperature and humidity values obtained from each gauge were compared with the values obtained with a thermistor and capacitive hygrometer. The results showed that the thermocouple gauges used (24, 32 and 40 AWG had high correlation and accuracy with values determined by the hygrometer (r2 > 0.97, RMSE P 3.91%.

  11. Cladding temperature measurement by thermocouples at preirradiated LWR fuel rod samples

    International Nuclear Information System (INIS)

    Leiling, W.

    1981-12-01

    This report describes the technique to measure cladding temperatures of test fuel rod samples, applied during the in-pile tests on fuel rod failure in the steam loop of the FR2 reactor. NiCr/Ni thermocouples with stainless steel and Inconel sheaths, respectively,of 1 mm diameter were resistance spot weld to the outside of the fuel rod cladding. For the pre-irradiated test specimens, welding had to be done under hot-cell conditions, i.e. under remote handling. In order to prevent the formation of eutectics between zirconium and the chemical elements of the thermocouple sheath at elevated temperatures, the thermocouples were covered with a platinum jacket of 1.4 mm outside diameter swaged onto the sheath in the area of the measuring junction. This thermocouple design has worked satisfactorily in the in-pile experiments performed in a steam atmosphere. Even in the heatup phase, in which cladding temperatures up to 1050 0 C were reached, only very few failures occured. This good performance is to a great part due to a careful control and a thorough inspection of the thermocouples. (orig.) [de

  12. Core exit thermocouple upgrade at Zion station

    International Nuclear Information System (INIS)

    Ulinski, T.M.; Ferg, D.A.

    1989-01-01

    Following the Three Mile Island accident, the ability of the core exit thermocouple (CET) system to monitor reactor core conditions and core cooling status became a requirement of the U.S. Nuclear Regulatory Commission (NRC). Since the thermocouple system at Zion station was not originally required for postaccident monitoring, Commonwealth Edison Company (CECo) committed to upgrading the CET system and to installing a subcooling margin monitoring (SMM) system. The significance of this commitment was that CECo proposed to accomplish the upgrade effort using internal resources and by developing the required in-house expertise instead of procuring integrated packages from several nuclear steam supply system vendors. The result was that CECo was able to demonstrate a number of new capabilities and unique design features with a significant cost savings. These included a qualified connector with an integral thermocouple cold-reference junction temperature compensation; the design, assembly, testing, and installation of a seismically qualified class 1E microprocessor; a commercial-grade dedication/upgrade process for safety-related hardware; a human factors review capability, and a verification and validation program for safety-related software. A discussion of these new capabilities and details of the design features is presented in this paper

  13. Chemical-technological approach to the selection of ceramic materials with predetermined thermistor properties

    Energy Technology Data Exchange (ETDEWEB)

    Plewa, J.; Altenburg, H. [Fachhochschule Muenster, Steinfurt (Germany). SIMa and Supraleiter-Keramik-Kristalle; Brunner, M. [Fachhochschule Koeln (Germany). Elektronische Bauelemente; Shpotyuk, O.; Vakiv, M. [Scientific Research Co. ' ' Carat' ' , Lviv Scientific Research Inst. of Materials, Lviv (Ukraine)

    2002-07-01

    The selection possibilities of quaternary Cu-Ni-Co-Mn oxide system restricted by cubic spinels (CuMn{sub 2}O{sub 4}, MnCo{sub 2}O{sub 4} and NiMn{sub 2}O{sub 4}) for NTC thermistors application were discussed. Phase compositions, microstructural features and electrical properties of the investigated spinel-structured ceramics were studied in tight connection with technological regimes of their sintering. (orig.)

  14. Failure of sheathed thermocouples due to thermal cycling

    International Nuclear Information System (INIS)

    Anderson, R.L.; Ludwig, R.L.

    1982-03-01

    Open circuit failures (up to 100%) in small-diameter thermocouples used in electrically heated nuclear fuel rod simulator prototypes during thermal cycling tests were investigated to determine the cause(s) of the failures. The experiments conducted to determine the relative effects of differential thermal expansion, wire size, grain size, and manufacturing technology are described. It was concluded that the large grain size and embrittlement which result from certain common manufacturing annealing and drawing procedures were a major contributing factor in the breakage of the thermocouple wires

  15. The transient response for different types of erodable surface thermocouples using finite element analysis

    Directory of Open Access Journals (Sweden)

    Mohammed Hussein

    2007-01-01

    Full Text Available The transient response of erodable surface thermocouples has been numerically assessed by using a two dimensional finite element analysis. Four types of base metal erodable surface thermocouples have been examined in this study, included type-K (alumel-chromel, type-E (chromel-constantan, type-T (copper-constantan, and type-J (iron-constantan with 50 mm thick- ness for each. The practical importance of these types of thermocouples is to be used in internal combustion engine studies and aerodynamics experiments. The step heat flux was applied at the surface of the thermocouple model. The heat flux from the measurements of the surface temperature can be commonly identified by assuming that the heat transfer within these devices is one-dimensional. The surface temperature histories at different positions along the thermocouple are presented. The normalized surface temperature histories at the center of the thermocouple for different types at different response time are also depicted. The thermocouple response to different heat flux variations were considered by using a square heat flux with 2 ms width, a sinusoidal surface heat flux variation width 10 ms period and repeated heat flux variation with 2 ms width. The present results demonstrate that the two dimensional transient heat conduction effects have a significant influence on the surface temperature history measurements made with these devices. It was observed that the surface temperature history and the transient response for thermocouple type-E are higher than that for other types due to the thermal properties of this thermocouple. It was concluded that the thermal properties of the surrounding material do have an impact, but the properties of the thermocouple and the insulation materials also make an important contribution to the net response.

  16. Enhancing Linearity of Voltage Controlled Oscillator Thermistor Signal Conditioning Circuit Using Linear Search

    Science.gov (United States)

    Rana, K. P. S.; Kumar, Vineet; Prasad, Tapan

    2018-02-01

    Temperature to Frequency Converters (TFCs) are potential signal conditioning circuits (SCCs) usually employed in temperature measurements using thermistors. A NE/SE-566 based SCC has been recently used in several reported works as TFC. Application of NE/SE-566 based SCC requires a mechanism for finding the optimal values of SCC parameters yielding the optimal linearity and desired sensitivity performances. Two classical methods, namely, inflection point and three point have been employed for this task. In this work, the application of these two methods, on NE/SE-566 based SCC in TFC, is investigated in detail and the conditions for its effective usage are developed. Further, since these classical methods offer an approximate linearization of temperature and frequency relationship an application of a linear search based technique is proposed to further enhance the linearity. The implemented linear search method used results obtained from the above mentioned classical methods. The presented simulation studies, for three different industrial grade thermistors, revealed that the linearity enhancements of 21.7, 18.3 and 17.8% can be achieved over the inflection point method and 4.9, 4.7 and 4.7% over the three point method, for an input temperature range of 0-100 °C.

  17. Lifetime improvement of sheathed thermocouples for use in high-temperature and thermal transient operations

    International Nuclear Information System (INIS)

    McCulloch, R.W.; Clift, J.H.

    1982-01-01

    Premature failure of small-diameter, magnesium-oxide-insulated sheathed thermocouples occurred when they were placed within nuclear fuel rod simulators (FRSs) to measure high temperatures and to follow severe thermal transients encountered during simulation of nuclear reactor accidents in Oak Ridge National Laboratory (ORNL) thermal-hydraulic test facilities. Investigation of thermally cycled thermocouples yielded three criteria for improvement of thermocouple lifetime: (1) reduction of oxygen impurities prior to and during their fabrication, (2) refinement of thermoelement grain size during their fabrication, and (3) elimination of prestrain prior to use above their recrystallization temperature. The first and third criteria were satisfied by improved techniques of thermocouple assembly and by a recovery anneal prior to thermocouple use

  18. Small thermistors for the measurement of heat transfer coefficients; Kleine Thermistoren zur Messung von Waermeuebergangskoeffizienten

    Energy Technology Data Exchange (ETDEWEB)

    Uffrecht, Wieland; Guenther, Andre [TU Dresden (Germany). Inst. fuer Stroemungsmechanik; Caspary, Volker [MAN Diesel und Turbo SE, Oberhausen (Germany)

    2012-07-01

    The measurement of heat transfer coefficients at rotating machine parts is a difficult measurement task and is particularily challenging for fast rotating parts with good thermal conductivity in combination with gaseous flow. This contribution reports about the test of a setup with small thermistors employed to achieve compatibility with the demands of telemetry. (orig.)

  19. Structural evaluation of thermocouple probes for 241-AZ-101 waste tank

    International Nuclear Information System (INIS)

    Kanjilal, S.K.

    1994-01-01

    This document reports on the structural analysis of the thermocouple probe to be installed in 241-AZ-101 waste tank. The thermocouple probe is analyzed for normal pump mixing operation and potential earthquake induced loads required by the Hanford Site Design Criteria SDC-4.1

  20. Structural evaluation of thermocouple probes for 241-AZ-101 waste tank

    Energy Technology Data Exchange (ETDEWEB)

    Kanjilal, S.K.

    1994-12-06

    This document reports on the structural analysis of the thermocouple probe to be installed in 241-AZ-101 waste tank. The thermocouple probe is analyzed for normal pump mixing operation and potential earthquake induced loads required by the Hanford Site Design Criteria SDC-4.1.

  1. An experimental study of the effect of external thermocouples on rewetting during reflood

    International Nuclear Information System (INIS)

    Shires, G.L.; Butcher, A.A.; Carpenter, B.G.; McCune, D.S.; Pearson, K.G.

    1980-04-01

    The validation of computer codes used for PWR safety assessment often depends upon experiments carried out with either real fuel pins or electrically heated fuel pin simulators. In some cases, and this applies particularly to in-pile tests, temperatures are measured by means of sheathed thermocouples attached externally to the pins and this raises the question of the possible effect of such thermocouples on the two phase hydraulics and heat transfer which are being studied. This paper describes the experiments which subjected two realistic fuel pin simulators, one with and one without external thermocouples, to identical bottom flooding conditions. They demonstrate very clearly that external thermocouples act as preferential rewetting sites and thereby increase the rate of propagation of the quench front. In the view of the authors of this paper the facts described raise serious doubts about the validity of rewetting data obtained from experiments employing external thermocouples. (U.K.)

  2. A Modified Design of a Thermocouple Based Digital Temperature Indicator with Opto-Isolation

    Directory of Open Access Journals (Sweden)

    S. C. BERA

    2008-01-01

    Full Text Available In the conventional thermocouple based digital temperature indicator the millivolt signal obtained from a thermocouple is first amplified and then converted into a digital signal by using analog-to-digital converter (ADC. This digital signal is then indicated as digital display of temperature using digital counter circuit or microprocessor/microcontroller based circuitry. In the present paper a modified AD conversion technique along with opto-isolation is used to indicate digitally the temperature without using any conventional analog-to-digital converter. The theory and design of the measuring technique are described in the paper. The non-linearity of thermocouple is eliminated by using look-up table within software program. The performance of the circuit has been experimentally tested by using mV input signal instead of a thermocouple as well as using a K-type thermocouple. The experimental results are reported in the paper.

  3. Thermoelectric properties of currently available Au/Pt thermocouples related to the valid reference function

    Directory of Open Access Journals (Sweden)

    Edler F.

    2015-01-01

    Full Text Available Au/Pt thermocouples are considered to be an alternative to High Temperature Standard Platinum Resistance Thermometers (HTSPRTs for realizing temperatures according to the International Temperature Scale of 1990 (ITS-90 in the temperature range between aluminium (660.323 °C and silver (961.78 °C. The original aim of this work was to develop and to validate a new reference function for Au/Pt thermocouples which reflects the properties of presently commercially available Au and Pt wires. The thermoelectric properties of 16 Au/Pt thermocouples constructed at different National Metrological Institutes by using wires from different suppliers and 4 commercially available Au/Pt thermocouples were investigated. Most of them exhibit significant deviations from the current reference function of Au/Pt thermocouples caused by the poor performance of the Au-wires available. Thermoelectric homogeneity was investigated by measuring immersion profiles during freezes at the freezing point of silver and in liquid baths. The thermoelectric inhomogeneities were found to be one order of magnitude larger than those of Au/Pt thermocouples of the Standard Reference Material® (SRM® 1749. The improvement of the annealing procedure of the gold wires is a key process to achieve thermoelectric homogeneities in the order of only about (2–3 mK, sufficient to replace the impracticable HTSPRTs as interpolation instruments of the ITS-90. Comparison measurements of some of the Au/Pt thermocouples against a HTSPRT and an absolutely calibrated radiation thermometer were performed and exhibit agreements within the expanded measurement uncertainties. It has been found that the current reference function of Au/Pt thermocouples reflects adequately the thermoelectric properties of currently available Au/Pt thermocouples.

  4. Temperature measurements from a moored thermistor chain in Mamala Bay, Oahu, Hawaii during 1997-1998 (NODC Accession 0000625)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A moored thermistor chain was deployed about a mile south of Honolulu Harbor in waters of about 260 feet depth. The instrument was in operation from August 1997 -...

  5. Magnetic tunnel junction thermocouple for thermoelectric power harvesting

    Science.gov (United States)

    Böhnert, T.; Paz, E.; Ferreira, R.; Freitas, P. P.

    2018-05-01

    The thermoelectric power generated in magnetic tunnel junctions (MTJs) is determined as a function of the tunnel barrier thickness for a matched electric circuit. This study suggests that lower resistance area product and higher tunnel magnetoresistance will maximize the thermoelectric power output of the MTJ structures. Further, the thermoelectric behavior of a series of two MTJs, a MTJ thermocouple, is investigated as a function of its magnetic configurations. In an alternating magnetic configurations the thermovoltages cancel each other, while the magnetic contribution remains. A large array of MTJ thermocouples could amplify the magnetic thermovoltage signal significantly.

  6. A thermal sensor for water using self-heated NTC thick-film segmented thermistors

    OpenAIRE

    Nikolić, Maria Vesna; Radojčić, B. M.; Aleksić, Obrad; Luković, Miloljub D.; Nikolić, Pantelija

    2011-01-01

    A simple thermal (heat loss) sensor system was designed in a small plastic tube housing using a negative thermal coefficient (NTC) thick-film thermistor as a self-heating sensor. The voltage power supply [range constant voltage (RCV)-range constant voltage] uses the measured input water temperature to select the applied voltage in steps (up and down) in order to enable operation of the sensor at optimal sensitivity for different water temperatures. The input water temperature was measured usi...

  7. Thermocouple Errors when Mounted on Cylindrical Surfaces in Abnormal Thermal Environments.

    Energy Technology Data Exchange (ETDEWEB)

    Nakos, James T. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Suo-Anttila, Jill M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Zepper, Ethan T. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Koenig, Jerry J [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Valdez, Vincent A. [ECI Inc., Albuquerque, NM (United States)

    2017-05-01

    Mineral-insulated, metal-sheathed, Type-K thermocouples are used to measure the temperature of various items in high-temperature environments, often exceeding 1000degC (1273 K). The thermocouple wires (chromel and alumel) are protected from the harsh environments by an Inconel sheath and magnesium oxide (MgO) insulation. The sheath and insulation are required for reliable measurements. Due to the sheath and MgO insulation, the temperature registered by the thermocouple is not the temperature of the surface of interest. In some cases, the error incurred is large enough to be of concern because these data are used for model validation, and thus the uncertainties of the data need to be well documented. This report documents the error using 0.062" and 0.040" diameter Inconel sheathed, Type-K thermocouples mounted on cylindrical surfaces (inside of a shroud, outside and inside of a mock test unit). After an initial transient, the thermocouple bias errors typically range only about +-1-2% of the reading in K. After all of the uncertainty sources have been included, the total uncertainty to 95% confidence, for shroud or test unit TCs in abnormal thermal environments, is about +-2% of the reading in K, lower than the +-3% typically used for flat shrouds. Recommendations are provided in Section 6 to facilitate interpretation and use of the results. .

  8. An Innovative Flow-Measuring Device: Thermocouple Boundary Layer Rake

    Science.gov (United States)

    Hwang, Danny P.; Fralick, Gustave C.; Martin, Lisa C.; Wrbanek, John D.; Blaha, Charles A.

    2001-01-01

    An innovative flow-measuring device, a thermocouple boundary layer rake, was developed. The sensor detects the flow by using a thin-film thermocouple (TC) array to measure the temperature difference across a heater strip. The heater and TC arrays are microfabricated on a constant-thickness quartz strut with low heat conductivity. The device can measure the velocity profile well into the boundary layer, about 65 gm from the surface, which is almost four times closer to the surface than has been possible with the previously used total pressure tube.

  9. Low drift type N thermocouples in out-of-pile advanced gas reactor mock-up test: metallurgical analysis

    International Nuclear Information System (INIS)

    Scervini, M.; Palmer, J.; Haggard, D.C.; Swank, W.D.

    2015-01-01

    Thermocouples are the most commonly used sensors for temperature measurement in nuclear reactors. They are crucial for the control of current nuclear reactors and for the development of GEN IV reactors. In nuclear applications thermocouples are strongly affected by intense neutron fluxes. As a result of the interaction with neutrons, the thermoelements of the thermocouples undergo transmutation, which produces a time dependent change in composition and, as a consequence, a time dependent drift of the thermocouple signal. Thermocouple drift can be very significant for in-pile temperature measurements and may render the temperature sensors unreliable after exposure to nuclear radiation for relatively short times compared to the life required for temperature sensors in nuclear applications. Previous experiences with type K thermocouples in nuclear reactors have shown that they are affected by neutron irradiation only to a limited extent. Similarly type N thermocouples are expected to be only slightly affected by neutron fluxes. Currently the use of Nickel based thermocouples is limited to temperatures lower than 1000 deg. C due to drift related to phenomena other than nuclear irradiation. As part of a collaboration between Idaho National Laboratory (INL) and the University of Cambridge a variety of Type N thermocouples have been exposed at INL in an Advanced Gas Reactor mock-up test at 1150 deg. C for 2000 h, 1200 deg. C for 2000 h, 125 deg. C for 200 h and 1300 deg. C for 200 h, and later analysed metallurgically at the University of Cambridge. The use of electron microscopy allows to identify the metallurgical changes occurring in the thermocouples during high temperature exposure and correlate the time dependent thermocouple drift with the microscopic changes experienced by the thermoelements of different thermocouple designs. In this paper conventional Inconel 600 sheathed type N thermocouples and a type N using a customized sheath developed at the University of

  10. Low drift type N thermocouples in out-of-pile advanced gas reactor mock-up test: metallurgical analysis

    Energy Technology Data Exchange (ETDEWEB)

    Scervini, M. [University of Cambridge, Department of Materials Science and Metallurgy, 27 Charles Babbage Road, CB30FS Cambridge, (United Kingdom); Palmer, J.; Haggard, D.C.; Swank, W.D. [Idaho National Laboratory, Idaho Falls, ID 83415-3840, (United States)

    2015-07-01

    Thermocouples are the most commonly used sensors for temperature measurement in nuclear reactors. They are crucial for the control of current nuclear reactors and for the development of GEN IV reactors. In nuclear applications thermocouples are strongly affected by intense neutron fluxes. As a result of the interaction with neutrons, the thermoelements of the thermocouples undergo transmutation, which produces a time dependent change in composition and, as a consequence, a time dependent drift of the thermocouple signal. Thermocouple drift can be very significant for in-pile temperature measurements and may render the temperature sensors unreliable after exposure to nuclear radiation for relatively short times compared to the life required for temperature sensors in nuclear applications. Previous experiences with type K thermocouples in nuclear reactors have shown that they are affected by neutron irradiation only to a limited extent. Similarly type N thermocouples are expected to be only slightly affected by neutron fluxes. Currently the use of Nickel based thermocouples is limited to temperatures lower than 1000 deg. C due to drift related to phenomena other than nuclear irradiation. As part of a collaboration between Idaho National Laboratory (INL) and the University of Cambridge a variety of Type N thermocouples have been exposed at INL in an Advanced Gas Reactor mock-up test at 1150 deg. C for 2000 h, 1200 deg. C for 2000 h, 125 deg. C for 200 h and 1300 deg. C for 200 h, and later analysed metallurgically at the University of Cambridge. The use of electron microscopy allows to identify the metallurgical changes occurring in the thermocouples during high temperature exposure and correlate the time dependent thermocouple drift with the microscopic changes experienced by the thermoelements of different thermocouple designs. In this paper conventional Inconel 600 sheathed type N thermocouples and a type N using a customized sheath developed at the University of

  11. Establishment of the Co-C Eutectic Fixed-Point Cell for Thermocouple Calibrations at NIMT

    Science.gov (United States)

    Ongrai, O.; Elliott, C. J.

    2017-08-01

    In 2015, NIMT first established a Co-C eutectic temperature reference (fixed-point) cell measurement capability for thermocouple calibration to support the requirements of Thailand's heavy industries and secondary laboratories. The Co-C eutectic fixed-point cell is a facility transferred from NPL, where the design was developed through European and UK national measurement system projects. In this paper, we describe the establishment of a Co-C eutectic fixed-point cell for thermocouple calibration at NIMT. This paper demonstrates achievement of the required furnace uniformity, the Co-C plateau realization and the comparison data between NIMT and NPL Co-C cells by using the same standard Pt/Pd thermocouple, demonstrating traceability. The NIMT measurement capability for noble metal type thermocouples at the new Co-C eutectic fixed point (1324.06°C) is estimated to be within ± 0.60 K (k=2). This meets the needs of Thailand's high-temperature thermocouple users—for which previously there has been no traceable calibration facility.

  12. Degradation by radiation of the response of a thermocouple of a fuel element

    International Nuclear Information System (INIS)

    Rodriguez V, A.

    1994-01-01

    In the TRIGA Mark III Reactor of the National Institute of Nuclear Research, is necessary to use an instrumented fuel element for measurement the fuel temperature during pulses of power. This fuel element is exposed to daily temperature gradient of order to 390 Centigrade degrees in normal condition of reactor operation at 1 MW. The experience which this instrumented fuel elements is that useful life of the thermocouples is less then the fuel, because they show important changes in their chemistry composition and electrical specifications, until the point they don't give any response. So is necessary to know the factors that influenced in the shortening of the thermocouples life. The change in composition affects the thermocouple calibration depends on where the changes take place relative to the temperature gradient. The change will be dependent on the neutron flux and so the value of the neutron flux may be used as a measure or the composition change. If there is no neutron flux within the temperature gradient, there will be no composition change, and so the thermocouple calibration will no change. If the neutron flux varies within the region in which a temperature gradients exists, the composition of the thermocouple will vary and the calibration will change. But the maximum change in calibration will occur if the neutron flux is high and constant within the region of the temperature gradient. In this case, a composition change takes place which is uniform throughout the gradient and so the emf output can be expected to change. In this reactor, the thermocouples are in the second case. Then, the relative position of the thermal and neutron flux gradients are the most important factor that explain the composition change after or 2,500 times of exposing the thermocouples to the temperature gradients of order to 390 Centigrade degrees. (Author)

  13. Evaluation of thermocouple fin effect in cladding surface temperature measurement during film boiling

    International Nuclear Information System (INIS)

    Tsuruta, Takaharu; Fujishiro, Toshio

    1984-01-01

    Thermocouple fin effect on surface temperature measurement of a fuel rod has been studied at elevated wall temperatures under film boiling condition in a reactivity initiated accident (RIA) situation. This paper presents an analytical equation to evaluate temperature drops caused by the thermocouple wires attached to cladding surface. The equation yielded the local temperature drop at measuring point depending on thermocouple diameter, cladding temperature, coolant flow condition and vapor film thickness. The temperature drops by the evaluating equation were shown in cases of free and forced convection conditions. The analytical results were compared with the measured data for various thermocouple sizes, and also with the estimated maximum cladding temperature based on the oxidation layer thickness in the cladding outer surface. It was concluded that the temperature drops at above 1,000 0 C in cladding temperature were around 120 and 150 0 C for 0.2 and 0.3 mm diameter Pt-Pt.Rh thermocouples, respectively, under a stagnant coolant condition. The fin effect increases with the decrease of vapor film thickness such as under forced flow cooling or at near the quenching point. (author)

  14. Thermocouple Rakes for Measuring Boundary Layer Flows Extremely Close to Surface

    Science.gov (United States)

    Hwang, Danny P.; Fralick, Gustave C.; Martin, Lisa C.; Blaha, Charles A.

    2001-01-01

    Of vital interest to aerodynamic researchers is precise knowledge of the flow velocity profile next to the surface. This information is needed for turbulence model development and the calculation of viscous shear force. Though many instruments can determine the flow velocity profile near the surface, none of them can make measurements closer than approximately 0.01 in. from the surface. The thermocouple boundary-layer rake can measure much closer to the surface than conventional instruments can, such as a total pressure boundary layer rake, hot wire, or hot film. By embedding the sensors (thermocouples) in the region where the velocity is equivalent to the velocity ahead of a constant thickness strut, the boundary-layer flow profile can be obtained. The present device fabricated at the NASA Glenn Research Center microsystem clean room has a heater made of platinum and thermocouples made of platinum and gold. Equal numbers of thermocouples are placed both upstream and downstream of the heater, so that the voltage generated by each pair at the same distance from the surface is indicative of the difference in temperature between the upstream and downstream thermocouple locations. This voltage differential is a function of the flow velocity, and like the conventional total pressure rake, it can provide the velocity profile. In order to measure flow extremely close to the surface, the strut is made of fused quartz with extremely low heat conductivity. A large size thermocouple boundary layer rake is shown in the following photo. The latest medium size sensors already provide smooth velocity profiles well into the boundary layer, as close as 0.0025 in. from the surface. This is about 4 times closer to the surface than the previously used total pressure rakes. This device also has the advantage of providing the flow profile of separated flow and also it is possible to measure simultaneous turbulence levels within the boundary layer.

  15. Thermocouples calibration and analysis of the influence of the length of the sensor coating

    International Nuclear Information System (INIS)

    Noriega, M; Ramírez, R; López, R; Vaca, M; Morales, J; Terres, H; Lizardi, A; Chávez, S

    2015-01-01

    This paper presents the design and construction of a lab prototype, with a much lower cost compared to the ones commercially sold, enabling the manufacture of thermocouples which are then calibrated to verify their functionality and acceptance. We also analyze the influence of the external insulation over the wires, to determine whether it influences temperature measurement. The tested lengths ranged from 0.00 m up to 0.030 m. The thermocouple was compared against the behavior of a thermocouple of the same type that was purchased with a commercial supplier. The obtained measurement showed less than 1 °C difference in some points. This makes the built thermocouple reliable, since the standard allows a difference of up to 2.2 °C

  16. Synthesising and comparing electrical properties of NTC thermistors prepared from nano powder and solid state reaction

    International Nuclear Information System (INIS)

    Azad, N.; Ghanbari Shohany, B.; Hosseini, S. M.; Kompany, A.

    2011-01-01

    In this research, NTC thermistors with composition of NiMn 2-x Co x O 4 (x = 0.4, 0.8, 1.2, 1.6) prepared by two methods: solid state reaction and sol-gel (gel-combustion). The average particle size was monitored and structure of the calcinated powders have been investigated using x-ray diffraction and tunneling electron microscopy techniques. The average particle size was estimated to be about 65 nm with the cubic and cubic + tetragonal phases for low and high cobalt concentrations, respectively. The grain size of samples verifies with scanning electron microscopy images. Upon increasing the cobalt fraction, the grain size of samples increases from about 2μm to a few μm in size. The electrical properties of these thermistors depend on the grain size. The grain size of samples made from sol-gel is smaller than from solid state reaction under the same condition. For longer sintering time of the samples prepared by gel-combustion method, the grain size was increased then the electrical parameters of nano powder improved and we obtain better results than the samples prepared from solid state reaction.

  17. Direct Measurement of Neutral/Ion Beam Power using Thermocouple Analysis

    International Nuclear Information System (INIS)

    Day, I.; Gee, S.

    2006-01-01

    Modern Neutral Beam Injection systems such as those used on JET and MAST routinely use thermocouples embedded close to the surface of beam stopping elements, such as calorimeters and ion dumps, coupled to high speed data acquisition systems to determine beam profile and position from temperature rise data. With the availability of low cost data acquisition and storage systems it is now possible to record data from all thermocouples in a fully instrumented calorimeter or ion dump on 20 ms timescales or better. This sample rate is sufficiently fast to enable the thermocouple data to be used to calculate the incident power density from 1d heat transfer theory. This power density data coupled with appropriate Gaussian fits enables the determination of the 2d beam profile and thus allows an instantaneous and direct measurement of beam power. The theory and methodology required to analyse the fast thermocouple data from the MAST calorimeter and residual ion dump thermocouples is presented and direct measurements of beam power density are demonstrated. The power of desktop computers allows such analysis to be carried out virtually instantaneously. The methods used to automate this analysis are discussed in detail. A code, utilising the theory and methodology, has been developed to allow immediate measurements of beam power on a pulse by pulse basis. The uncertainty in determining the beam power density is shown to be less than 10 %. This power density data is then fitted to a 2d Gaussian beam profile and integrated to establish the total beam power. Results of this automated analysis for the neutral beam and residual ion power of the MAST duopigatron and PINI NBI systems are presented. This technology could be applied to a beam power safety interlock system. The application to a beam shine through protection system for the inner wall of the JET Tokamak is discussed as an example. (author)

  18. Thermal Recovery from Cold-Working in Type K Bare-Wire Thermocouples

    Science.gov (United States)

    Greenen, A. D.; Webster, E. S.

    2017-12-01

    Cold-working of most thermocouples has a significant, direct impact on the Seebeck coefficient which can lead to regions of thermoelectric inhomogeneity and accelerated drift. Cold-working can occur during the wire swaging process, when winding the wire onto a bobbin, or during handling by the end user—either accidentally or deliberately. Swaging-induced cold-work in thermocouples, if uniformly applied, may result in a high level of homogeneity. However, on exposure to elevated temperatures, the subsequent recovery process from the cold-working can then result in significant drift, and this can in turn lead to erroneous temperature measurements, often in excess of the specified manufacturer tolerances. Several studies have investigated the effects of cold-work in Type K thermocouples usually by bending, or swaging. However, the amount of cold-work applied to the thermocouple is often difficult to quantify, as the mechanisms for applying the strains are typically nonlinear when applied in this fashion. A repeatable level of cold-working is applied to the different wires using a tensional loading apparatus to apply a known yield displacement to the thermoelements. The effects of thermal recovery from cold-working can then be accurately quantified as a function of temperature, using a linear gradient furnace and a high-resolution homogeneity scanner. Variation in these effects due to differing alloy compositions in Type K wire is also explored, which is obtained by sourcing wire from a selection of manufacturers. The information gathered in this way will inform users of Type K thermocouples about the potential consequences of varying levels of cold-working and its impact on the Seebeck coefficient at a range of temperatures between ˜ 70°C and 600° C. This study will also guide users on the temperatures required to rapidly alleviate the effects of cold-working using thermal annealing treatments.

  19. Water calorimetry with thermistor bridge operated in DC and AC mode: comparative results

    International Nuclear Information System (INIS)

    Guerra, A.S.; Laitano, R.F.; Petrocchi, A.

    1997-01-01

    An experimental study was carried out to find out the optimal conditions for measuring the output signal in a water calorimeter. To this end the thermistor bridge of the calorimeter was operated in AC and in DC mode, respectively. A comparative analysis of these two alternative methods was the made. In the AC mode measurement a lock-in amplifier based experimental assembly was used and compared to the more conventional system based on a high-sensitivty DC amplifier. The AC system resulted to be preferable as far as the short term and long term reproducibility is concerned. (orig.)

  20. Water calorimetry with thermistor bridge operated in DC and AC mode: comparative results

    Energy Technology Data Exchange (ETDEWEB)

    Guerra, A S; Laitano, R F; Petrocchi, A [Ist. Nazionale di Metrologia delle Radiazioni Ionizzanti, ENEA, Roma (Italy)

    1997-09-01

    An experimental study was carried out to find out the optimal conditions for measuring the output signal in a water calorimeter. To this end the thermistor bridge of the calorimeter was operated in AC and in DC mode, respectively. A comparative analysis of these two alternative methods was the made. In the AC mode measurement a lock-in amplifier based experimental assembly was used and compared to the more conventional system based on a high-sensitivty DC amplifier. The AC system resulted to be preferable as far as the short term and long term reproducibility is concerned. (orig.)

  1. Thermistor guided radiofrequency ablation of atrial insertion sites in patients with accessory pathways.

    Science.gov (United States)

    Tracy, C M; Moore, H J; Solomon, A J; Rodak, D J; Fletcher, R D

    1995-11-01

    Radiofrequency ablation has gained acceptance in the treatment of patients with symptomatic Wolff-Parkinson-White syndrome. The purpose of this study was to characterize the relation between temperature and other electroconductive parameters in patients undergoing atrial insertion accessory pathway ablation utilizing a thermistor equipped catheter. The mean temperature and power at sites of atrial insertion ablation are lower than has been previously associated with creation of radiofrequency lesions in the ventricle. While high cavitary blood flow in the atrium may result in cooling, the thinner atrial tissue may require less energy to achieve adequate heating than ventricular myocardium.

  2. Calibration Technique of the Irradiated Thermocouple using Artificial Neural Network

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Jin Tae; Joung, Chang Young; Ahn, Sung Ho; Yang, Tae Ho; Heo, Sung Ho; Jang, Seo Yoon [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    To correct the signals, the degradation rate of sensors needs to be analyzed, and re-calibration of sensors should be followed periodically. In particular, because thermocouples instrumented in the nuclear fuel rod are degraded owing to the high neutron fluence generated from the nuclear fuel, the periodic re-calibration process is necessary. However, despite the re-calibration of the thermocouple, the measurement error will be increased until next re-calibration. In this study, based on the periodically calibrated temperature - voltage data, an interpolation technique using the artificial neural network will be introduced to minimize the calibration error of the C-type thermocouple under the irradiation test. The test result shows that the calculated voltages derived from the interpolation function have good agreement with the experimental sampling data, and they also accurately interpolate the voltages at arbitrary temperature and neutron fluence. That is, once the reference data is obtained by experiments, it is possible to accurately calibrate the voltage signal at a certain neutron fluence and temperature using an artificial neural network.

  3. Temperature measurement: Development work on noise thermometry and improvement of conventional thermocouples for applications in nuclear process heat (PNP)

    International Nuclear Information System (INIS)

    Brixy, H.; Hecker, R.; Oehmen, J.; Barbonus, P.; Hans, R.

    1982-06-01

    The behaviour was studied of NiCr-Ni sheathed thermocouples (sheath Inconel 600 or Incoloy 800, insulation MgO) in a helium and carbon atmosphere at temperatures of 950-1150 deg. C. All the thermocouples used retained their functional performance. The insulation resistance tended towards a limit value which is dependent on the temperature and quality of the thermocouple. Temperature measurements were loaded with great uncertainty in the temperature range of 950-1150 deg. C. Recalibrations at the temperature of 950 deg. C showed errors of up to 6%. Measuring sensors were developed which consist of a sheathed double thermocouple with a noise resistor positioned between the two hot junctions. Using the noise thermometer it is possible to recalibrate the thermocouple at any time in situ. A helium system with a high temperature experimental area was developed to test the thermocouples and the combined thermocouple-noise thermometer sensors under true experimental conditions

  4. Thermocouple calibration facility for 2900 deg C high temperature and its applications

    International Nuclear Information System (INIS)

    Chen Daolong

    1991-01-01

    The construction and the performance characteristic of a 2900 deg C high temperature thermocouple calibration facility are described. The calibration error analysis is made. The test results of the calibration characteristics of high temperature thermocouples Mo/Nb, W-3Re/W-25Re, and W-1Mo/W-25Mo are given. The test result of temperature dependent resistivity of BeO made by this facility is given

  5. Reply to ''Comment on 'Thermocouple temperature measurements in shock-compressed solids' ''

    International Nuclear Information System (INIS)

    Bloomquist, D.D.; Sheffield, S.A.

    1982-01-01

    We disagree with the interpretation offered in the above comment. The suggestion was made that the anomalously fast response of thin-foil thermocouples reported previously is the result of strain dependence of the thermocouple response and not shock enhanced thermal equilibration. Although the emplacement geometry has a profound effect on the response of embedded thin-foil temperature gauges as noted in the above comment, the evidence presented, along with recent results discussed in this reply, do not support the conclusions presented in the above comment

  6. A preliminary study of factors affecting the calibration stability of the iridium versus iridium-40 percent rhodium thermocouple

    Science.gov (United States)

    Ahmed, Shaffiq; Germain, Edward F.; Daryabeigi, Kamran; Alderfer, David W.; Wright, Robert E.

    1987-01-01

    An iridium versus iridium-40% rhodium thermocouple was studied. Problems associated with the use of this thermocouple for high temperature applications (up to 2000 C) were investigated. The metallurgical studies included X-ray, macroscopic, resistance, and metallographic studies. The thermocouples in the as-received condition from the manufacturer revealed large amounts of internal stress caused by cold working during manufacturing. The thermocouples also contained a large amount of inhomogeneities and segregations. No phase transformations were observed in the alloy up to 1100 C. It was found that annealing the thermocouple at 1800 C for two hours, and then at 1400 C for 2 to 3 hours yielded a fine grain structure, relieving some of the strains, and making the wire more ductile. It was also found that the above annealing procedure stabilized the thermal emf behavior of the thermocouple for application below 1800 C (an improvement from + or - 1% to + or - 0.02% within the range of the test parameters used).

  7. Study on thermocouple attachment in reflood experiments

    International Nuclear Information System (INIS)

    Sugimoto, Jun

    1977-03-01

    The method of thermocouple attachment to a heater rods has been studied for surface temperature measurement in reflood experiments. The method used as far in JAERI's reflood experiments had some possibilities of not estimating exactly the quench times. Various attachment method have been tested and some proved to be effective in the respect. (auth.)

  8. Zircaloy-sheathed element rods fitted with thermo-couples

    International Nuclear Information System (INIS)

    Bernardy de Sigoyer, B.; Jacques, F.; Thome, P.

    1963-01-01

    In order to carry out thermal conductivity measurements on UO 2 in conditions similar to those under which fuel rods are used, it was necessary to measure the temperature at the interior of a fuel element sheathed in zircaloy. The temperatures are taken with Thermocoax type thermocouples, that is to say fitted with a very thin sheath of stainless steel or Inconel. It is known also that fusion welding of zircaloy onto stainless steel is impossible and that high temperature welded joints are very difficult because of their aggressiveness. The technique used consists in brazing the thermocouples to relatively large stainless steel parts and then joining these plugs by electron bombardment welding to diffused stainless steel-zircaloy couplings. The properties of these diffused couplings and of the brazed joints were studied; the various stages in the fabrication of the containers are also described. (authors) [fr

  9. R and D advances in high temperature thermocouples for nuclear utilization in severe environment

    International Nuclear Information System (INIS)

    Schley, R.; Blanc, J.Y.

    1984-09-01

    Safety experiments for water reactors in Cadarache have made necessary a research program for developing special thermocouples for use in severe fuel damage conditions (superheated steam). Standard cladding thermocouples (type K, alumina insulated, zircaloy sheathed, O.D. 0.7 mm) must be replaced by others with W3Re versus W25Re legs, Ta sheath protected by a zircaloy outer sheath, and hafnia or thoria insulation. The zircaloy sheath will be sufficient to protect correctly tantalum. Fuel centerline thermocouples have W5Re versus W26Re or W3Re versus W25Re legs, hard-fired thoria insulation and rhenium CVD sheath (O.D. 1.1 mm). A protective ReSi 2 coating is applied. This protection withstands at least 1600 0 C, 45 minutes in steam. Tests are done-concerning: a) materials compatibilities in helium between 1400 0 C and 2000 0 C, b) prototypes qualification (in Saclay or Grenoble), c) determination of errors due to degradation of insulation resistance of thermocouples cables (with magnesia, hafnia, alumina), d) Ir or Re protective coatings by CVD process, other coatings by ionic bombardment, etc... A completely new type of hot junction has been patented. Future works will include: completion of these tests, Mo-Nb alloys thermocouples legs realization withstanding heavy neutronic fluence, and use of ceramics glues

  10. Temperature measurement error due to the effects of time varying magnetic fields on thermocouples with ferromagnetic thermoelements

    International Nuclear Information System (INIS)

    McDonald, D.W.

    1977-01-01

    Thermocouples with ferromagnetic thermoelements (iron, Alumel, Nisil) are used extensively in industry. We have observed the generation of voltage spikes within ferromagnetic wires when the wires are placed in an alternating magnetic field. This effect has implications for thermocouple thermometry, where it was first observed. For example, the voltage generated by this phenomenon will contaminate the thermocouple thermal emf, resulting in temperature measurement error

  11. Outdoor surface temperature measurement: ground truth or lie?

    Science.gov (United States)

    Skauli, Torbjorn

    2004-08-01

    Contact surface temperature measurement in the field is essential in trials of thermal imaging systems and camouflage, as well as for scene modeling studies. The accuracy of such measurements is challenged by environmental factors such as sun and wind, which induce temperature gradients around a surface sensor and lead to incorrect temperature readings. In this work, a simple method is used to test temperature sensors under conditions representative of a surface whose temperature is determined by heat exchange with the environment. The tested sensors are different types of thermocouples and platinum thermistors typically used in field trials, as well as digital temperature sensors. The results illustrate that the actual measurement errors can be much larger than the specified accuracy of the sensors. The measurement error typically scales with the difference between surface temperature and ambient air temperature. Unless proper care is taken, systematic errors can easily reach 10% of this temperature difference, which is often unacceptable. Reasonably accurate readings are obtained using a miniature platinum thermistor. Thermocouples can perform well on bare metal surfaces if the connection to the surface is highly conductive. It is pointed out that digital temperature sensors have many advantages for field trials use.

  12. Reversible thermal fusing model of carbon black current-limiting thermistors

    International Nuclear Information System (INIS)

    Martin, James E.; Heaney, Michael B.

    2000-01-01

    Composites of carbon black particles in polyethylene exhibit an unusually rapid increase in resistivity as the applied electric field is increased, making this material commercially useful as current-limiting thermistors, also known as automatically resettable fuses. In this application the composite is in series with the circuit it is protecting: at low applied voltages the circuit is the load, but at high applied voltages the composite becomes the load, limiting the current to the circuit. We present a simple model of this behavior in terms of a network of nonlinear resistors. Each resistor has a resistance that depends explicitly and reversibly on its instantaneous power dissipation. This model predicts that in the soft fusing, or current-limiting, regime, where the current through the composite decreases with increasing voltage, a platelike dissipation instability develops normal to the applied field, in agreement with experimental observations, which is solely due to fluctuations in the microstructure

  13. 78 FR 56174 - In-Core Thermocouples at Different Elevations and Radial Positions in Reactor Core

    Science.gov (United States)

    2013-09-12

    ... 52 [Docket No. PRM-50-105; NRC-2012-0056] In-Core Thermocouples at Different Elevations and Radial Positions in Reactor Core AGENCY: Nuclear Regulatory Commission. ACTION: Petition for rulemaking; denial...-core thermocouples at different elevations and radial positions throughout the reactor core to enable...

  14. Flexible screen printed thick film thermoelectric generator with reduced material resistivity

    International Nuclear Information System (INIS)

    Cao, Z; Koukharenko, E; Torah, R N; Tudor, J; Beeby, S P

    2014-01-01

    This work presents a flexible thick-film Bismuth Tellurium/Antimony Tellurium (BiTe/SbTe) thermoelectric generator (TEG) with reduced material resistivity fabricated by screen printing technology. Cold isostatic pressing (CIP) was introduced to lower the resistivity of the printed thermoelectric materials. The Seebeck coefficient (α) and the resistivity (ρ) of printed materials were measured as a function of applied pressure. A prototype TEG with 8 thermocouples was fabricated on flexible polyimide substrate. The dimension of a single printed element was 20 mm × 2 mm × 78.4 pm. The coiled-up prototype produced a voltage of 36.4 mV and a maximum power of 40.3 nW from a temperature gradient of 20 °C

  15. Analysis of heat transfer from fuel rods with externally attached thermocouples

    International Nuclear Information System (INIS)

    Gill, C.R.; Coddington, P.

    1988-05-01

    This paper describes the development of 2 and 3 dimensional finite element heat conduction models to simulate the behaviour of the external thermocouples attached to the LOFT fuel rods during the blowdown phase of a large break loss-of-coolant accident. To establish the model and determine the thermal coupling between the thermocouple and the fuel rod extensive use was made of two series of experiments performed at INEL in the LOFT Test Support Facility (LTSF). These experiments were high pressure reflood experiments with fluid conditions 'typical' of those seen during the bottom-up flow period of the LOFT experiments. (author)

  16. Using a thermistor flowmeter with attached video camera for monitoring sponge excurrent speed and oscular behaviour

    DEFF Research Database (Denmark)

    Strehlow, Brian W.; Jorgensen, Damien; Webster, Nicole S.

    2016-01-01

    A digital, four-channel thermistor flowmeter integrated with time-lapse cameras was developed as an experimental tool for measuring pumping rates in marine sponges, particularly those with small excurrent openings (oscula). Combining flowmeters with time-lapse imagery yielded valuable insights...... in pumping activity and osculum contraction were also observed, with sponges increasing their pumping activity to peak at midday and decreasing pumping and contracting oscula at night. Short-term elevation of the suspended sediment concentration (SSC) within the seawater initially decreased pumping rates...

  17. 77 FR 30435 - In-core Thermocouples at Different Elevations and Radial Positions in Reactor Core

    Science.gov (United States)

    2012-05-23

    ... NUCLEAR REGULATORY COMMISSION 10 CFR Part 50 [Docket No. PRM-50-105; NRC-2012-0056] In-core Thermocouples at Different Elevations and Radial Positions in Reactor Core AGENCY: Nuclear Regulatory Commission... of operating licenses for nuclear power plants (``NPP'') to operate NPPs with in-core thermocouples...

  18. Guidelines for Evaluating the Thermal Environment of Enclosed Spaces

    Science.gov (United States)

    2009-09-01

    probes Thermocouple and thermistor probes for air, soil, water, etc. Solar radiation LI-COR LI200 pyranometer Silicon diode – not for indoor use...Solar radiation Hukseflux LP02 pyranometer Thermopile sensor element – may be used indoors Black globe thermometer Commercial (original source...temperature (Tnwb) and RH. Exterior Solar Radiation Radiometers that measure solar radiation are called pyranometers . A pyranometer consists of a

  19. Difference equation approach to two-thermocouple sensor characterization in constant velocity flow environments

    International Nuclear Information System (INIS)

    Hung, P.C.; Irwin, G.; Kee, R.; McLoone, S.

    2005-01-01

    Thermocouples are one of the most popular devices for temperature measurement due to their robustness, ease of manufacture and installation, and low cost. However, when used in certain harsh environments, for example, in combustion systems and engine exhausts, large wire diameters are required, and consequently the measurement bandwidth is reduced. This article discusses a software compensation technique to address the loss of high frequency fluctuations based on measurements from two thermocouples. In particular, a difference equation (DE) approach is proposed and compared with existing methods both in simulation and on experimental test rig data with constant flow velocity. It is found that the DE algorithm, combined with the use of generalized total least squares for parameter identification, provides better performance in terms of time constant estimation without any a priori assumption on the time constant ratios of the thermocouples

  20. Determination of the availability of core exit thermocouples during severe accident situations

    International Nuclear Information System (INIS)

    Edson, J.L.

    1985-04-01

    This report presents the findings and recommendations of the Nuclear Power Plant Instrumentation Evaluation (NPPIE) program concerning signal validation methods to determine the on-line availability of core exit thermocouples during accident situations. Methods of selecting appropriate signal validation techniques are discussed and sources of error identified. This report shows that through the use of these techniques the existence of high-temperature-caused errors may be detected as they occur. Specific recommendations for application of selected signal validation techniques to core exit thermocouples and other measurement systems are made. 23 refs., 22 figs., 3 tabs

  1. Using high thermal stability flexible thin film thermoelectric generator at moderate temperature

    Science.gov (United States)

    Zheng, Zhuang-Hao; Luo, Jing-Ting; Chen, Tian-Bao; Zhang, Xiang-Hua; Liang, Guang-Xing; Fan, Ping

    2018-04-01

    Flexible thin film thermoelectric devices are extensively used in the microscale industry for powering wearable electronics. In this study, comprehensive optimization was conducted in materials and connection design for fabricating a high thermal stability flexible thin film thermoelectric generator. First, the thin films in the generator, including the electrodes, were prepared by magnetron sputtering deposition. The "NiCu-Cu-NiCu" multilayer electrode structure was applied to ensure the thermal stability of the device used at moderate temperature in an air atmosphere. A design with metal layer bonding and series accordant connection was then employed. The maximum efficiency of a single PN thermocouple generator is >11%, and the output power loss of the generator is <10% after integration.

  2. Classification of Unknown Thermocouple Types Using Similarity Factor Measurement

    Directory of Open Access Journals (Sweden)

    Seshu K. DAMARLA

    2011-01-01

    Full Text Available In contrast to classification using PCA method, a new methodology is proposed for type identification of unknown thermocouple. The new methodology is based on calculating the degree of similarity between two multivariate datasets using two types of similarity factors. One similarity factor is based on principle component analysis and the angles between the principle component subspaces while the other is based on the Mahalanobis distance between the datasets. Datasets containing thermo-emfs against given temperature ranges are formed for each type of thermocouple (e.g. J, K, S, T, R, E, B and N type by experimentation are considered as reference datasets. Datasets corresponding to unknown type are captured. Similarity factor between the datasets one of which being the unknown type and the other being each known type are compared. When maximum similarity factor occurs, then the class of unknown type is allocated to that of known type.

  3. A novel method for in-situ estimation of time constant for core temperature monitoring thermocouples of operating reactors

    International Nuclear Information System (INIS)

    Sylvia, J.I.; Chandar, S. Clement Ravi; Velusamy, K.

    2014-01-01

    Highlights: • Core temperature sensor was mathematically modeled. • Ramp signal generated during reactor operating condition is used. • Procedure and methodology has been demonstrated by applying it to FBTR. • Same technique will be implemented for all fast reactors. - Abstract: Core temperature monitoring system is an important component of reactor protection system in the current generation fast reactors. In this system, multiple thermocouples are housed inside a thermowell of fuel subassemblies. Response time of the thermocouple assembly forms an important input for safety analysis of fast reactor and hence frequent calibration/time constant estimation is essential. In fast reactors the central fuel subassembly is provided with bare fast response thermocouples to detect under cooling events in reactor and take proper safety action. On the other hand, thermocouples in thermowell are mainly used for blockage detection in individual fuel subassemblies. The time constant of thermocouples in thermowell can drift due to creep, vibration and thermal fatigue of the thermowell assembly. A novel method for in-situ estimation of time constant is proposed. This method uses the Safety Control Rod Accelerated Mechanism (SCRAM) or lowering of control Rod (LOR) signals of the reactor along with response of the central subassembly thermocouples as reference data. Validation of the procedure has been demonstrated by applying it to FBTR

  4. The disposition of can thermocouples in a nuclear reactor

    International Nuclear Information System (INIS)

    Wilkie, D.

    1978-01-01

    A philosophy is presented for deciding the distribution of can thermocouples within channels and of instrumented channels throughout the core of a reactor with cluster-type fuel elements when only a few thermocouples can be located in any one channel. The arrangement is made according to a 'factorial' design in which all fuel element positions of interest are covered in a group of channels. Two types of factorial design can be applied: the unconfounded design by which the thermocouples in each channel are chosen at random from the possible positions available, with the results that the temperatures have attached to them an uncertainty determined by the differences among channels; and the confounded design by which the positions are chosen so as to give temperatures whose uncertainty is determined only by the random variations within channels. It is also necessary to estimate standard deviations in order to predict the number of cans likely to reach a given temperature. The standard deviation can be expected to vary with channel position, and since there will also be systematic variations in temperature with channel position it is necessary to arrange channels into groups having similar mean fluxes and flux distributions. Each group is instrumented according to the pattern of a confounded design. The information that such an arrangement provides is an estimate of the systematic temperature variations within channels, estimates of within-channel variation of can temperature, of between-channel variation of can temperature, and of the variation of these quantities among groups of channels grouped according to similarity of mean flux and flux profile. (author)

  5. Thermocouple module halt failure acceptance test procedure for Tank 241-SY-101 DACS-1

    International Nuclear Information System (INIS)

    Ermi, A.M.

    1997-01-01

    The readiness of the Tank 241-SY-101 Data Acquisition and Control System (DACS-1) to provide monitoring and alarms for a halt failure of any thermocouple module will be tested during the performance of this procedure. Updated DACS-1 ''1/0 MODULE HEALTH STATUS'', ''MININ1'', and ''MININ2'' screens, which now provide indication of thermocouple module failure, will also be tested as part of this procedure

  6. Thermal conductivity and diffusivity of biomaterials measured with self-heated thermistors

    Science.gov (United States)

    Valvano, J. W.; Cochran, J. R.; Diller, K. R.

    1985-05-01

    This paper presents an experimental method to measure the thermal conductivity and thermal diffusivity of biomaterials. Self-heated thermistor probes, inserted into the tissue of interest, are used to deliver heat as well as to monitor the rate of heat removal. An empirical calibration procedure allows accurate thermal-property measurements over a wide range of tissue temperatures. Operation of the instrument in three media with known thermal properties shows the uncertainty of measurements to be about 2%. The reproducibility is 0.5% for the thermal-conductivity measurements and 2% for the thermal-diffusivity measurements. Thermal properties were measured in dog, pig, rabbit, and human tissues. The tissues included kidney, spleen, liver, brain, heart, lung, pancreas, colon cancer, and breast cancer. Thermal properties were measured for 65 separate tissue samples at 3, 10, 17, 23, 30, 37, and 45°C. The results show that the temperature coefficient of biomaterials approximates that of water.

  7. Evaluation of RTD and thermocouple for PID temperature control in ...

    African Journals Online (AJOL)

    Evaluation of RTD and thermocouple for PID temperature control in distributed control system laboratory. D. A. A. Nazarudin, M. K. Nordin, A. Ahmad, M. Masrie, M. F. Saaid, N. M. Thamrin, M. S. A. M. Ali ...

  8. Development of thermocouple re-instrumentation technique for irradiated fuel rod. Techniques for making center hole into UO2 pellets and thermocouple re-instrumentation to fuel rod

    International Nuclear Information System (INIS)

    Shimizu, Michio; Saito, Junichi; Oshima, Kunio

    1995-07-01

    The information on FP gas pressure and centerline temperature of fuel pellets during power transient is important to study the pellet clad interaction (PCI) mechanism of high burnup LWR fuel rods. At the Department of JMTR, a re-instrumentation technique of FP gas pressure gage for an irradiated fuel rod was developed in 1990. Furthermore, a thermocouple re-instrumentation technique was successfully developed in 1994. Two steps were taken to carry out the development program of the thermocouple re-instrumentation technique. In the first step, a drilling technique was developed for making a center hole of the irradiated fuel pellets. Various drilling tests were carried out using dummy of fuel rods consisted of Ba 2 FeO 3 pellets and Zry-2 cladding. On this work it is important to keep the pellets just the state cracked at a power reactor. In these tests, the technique to fix the pellets by frozen CO 2 was used during the drilling work. Also, diamond drills were used to make the center hole. These tests were completed successfully. A center hole, 54mm depth and 2.5mm diameter, was realized by these methods. The second step of this program is the in-pile demonstration test on an irradiated fuel rod instrumented dually a thermocouple and FP gas pressure gage. The demonstration test was carried out at the JMTR in 1995. (author)

  9. Relocation work of temporary thermocouples for measuring the vessel cooling system in the safety demonstration test

    International Nuclear Information System (INIS)

    Shimazaki, Yosuke; Shinohara, Masanori; Ono, Masato; Yanagi, Shunki; Tochio, Daisuke; Iigaki, Kazuhiko

    2012-05-01

    It is necessary to confirm that the temperature of water cooling panel of the vessel cooling system (VCS) is controlled under the allowable working temperature during the safety demonstration test because the water cooling panel temperature rises due to stop of cooling water circulation pumps. Therefore, several temporary thermocouples are relocated to the water cooling panel near the stabilizers of RPV and the side cooling panel outlet ring header of VCS in order to observe the temperature change of VCS. The relocated thermocouples can measure the temperature change with starting of the cooling water circulation pumps of VCS. So it is confirmed that the relocated thermocouples can observe the VCS temperature change in the safety demonstration test. (author)

  10. Apparatus for spot welding sheathed thermocouples to the inside of small-diameter tubes at precise locations

    International Nuclear Information System (INIS)

    Baucum, W.E.; Dial, R.E.

    1976-01-01

    Equipment and procedures used to spot weld tantalum- or stainless-steel-sheathed thermocouples to the inside diameter of Zircaloy tubing to meet the requirements of the Multirod Burst Test (MRBT) Program at ORNL are described. Spot welding and oxide cleaning tools were fabricated to remove the oxide coating on the Zircaloy tubing at local areas and spot weld four thermocouples separated circumferentially by 90 0 at any axial distribution desired. It was found necessary to apply a nickel coating to stainless-steel-sheathed thermocouples to obtain acceptable welds. The material and shape of the inner electrode and resistance between inner and outer electrodes were found to be critical parameters in obtaining acceptable welds

  11. Accuracy of small diameter sheathed thermocouples for the core flow test loop

    International Nuclear Information System (INIS)

    Anderson, R.L.; Kollie, T.G.

    1979-04-01

    This report summarizes the research and development on 0.5-mm-diameter, compacted, metal sheathed thermocouples. The objectives of this research effort have been: to identify and analyze the sources of temperature measurement errors in the use of 0.5-mm-diameter sheathed thermocouples to measure the surface temperature of the cladding of fuel-rod simulators in the Core Flow Test Loop (CFTL) at ORNL; to devise methods for reducing or correcting for these temperature measurement errors; to estimate the overall temperature measurement uncertainties; and to recommend modifications in the manufacture, installation, or materials used to minimize temperature measurement uncertainties in the CFTL experiments

  12. Novel thermocouples for automotive applications

    Directory of Open Access Journals (Sweden)

    P. Gierth

    2018-02-01

    Full Text Available Measurement of temperatures in engine and exhaust systems in automotive applications is necessary for thermal protection of the parts and optimizing of the combustion process. State-of-the-art temperature sensors are very limited in their response characteristic and installation space requirement. Miniaturized sensor concepts with a customizable geometry are needed. The basic idea of this novel sensor concept is to use thick-film technology on component surfaces. Different standardized and especially nonstandard material combinations of thermocouples have been produced for the validation of this technology concept. Application-oriented measurements took place in the exhaust system of a test vehicle and were compared to standard laboratory conditions.

  13. Experience from replacement and check of thermocouples during reconstruction of in-reactor temperature measurements at Bohunice V-1 units 1 and 2

    International Nuclear Information System (INIS)

    Slanina, M.; Stanc, J.

    2001-01-01

    Replacement of thermocouples in the protection tube blocks was a key phase of the reconstruction of in-reactor temperature measurements at Bohunice V-1 with regard to the success, reliability and impact on safety of unit operation. The replacement consisted of reliable and safe withdrawal of 216 old thermocouples, their disposal and installation of new thermocouples into dry channels. In the material presented, this phase of reconstruction is described in details, with focus on the evaluation of replacement quality and check activities carried out at the new installed thermocouples. (Authors)

  14. Temperature Control System for Chromel-Alumel Thermocouple

    International Nuclear Information System (INIS)

    Piping Supriatna; Nurhanan; Riswan DJ; Heru K, B.; Edi Karyanta

    2003-01-01

    Nuclear Power Plan Operation Safety needs serious handling on temperature measurement and control. In this report has been done manufacturing Temperature Control System for Chromel-Alumel Thermocouple, accordance to material, equipment and human resource ability in the laboratory. Basic component for the Temperature Control System is LM-741 type of Operation Amplifier, which is functionalized as summer for voltage comparator. Function test for this Control System shown its ability for damping on temperature reference. The Temperature Control System will be implemented on PCB Processing Machine. (author)

  15. A Highly Thermostable In2O3/ITO Thin Film Thermocouple Prepared via Screen Printing for High Temperature Measurements

    Directory of Open Access Journals (Sweden)

    Yantao Liu

    2018-03-01

    Full Text Available An In2O3/ITO thin film thermocouple was prepared via screen printing. Glass additives were added to improve the sintering process and to increase the density of the In2O3/ITO films. The surface and cross-sectional images indicate that both the grain size and densification of the ITO and In2O3 films increased with the increase in annealing time. The thermoelectric voltage of the In2O3/ITO thermocouple was 53.5 mV at 1270 °C at the hot junction. The average Seebeck coefficient of the thermocouple was calculated as 44.5 μV/°C. The drift rate of the In2O3/ITO thermocouple was 5.44 °C/h at a measuring time of 10 h at 1270 °C.

  16. Improvement in the technology of thermocouples for the detection of high temperatures with a view to using them in irradiation safety tests in reactor

    International Nuclear Information System (INIS)

    Schley, R.; Liermann, J.; Aujollet, J.M.; Wilkins, S.C.

    1979-01-01

    The safety tests carried out under the CABRI and PHEBUS programmes have made it possible to improve the technology of W/Re thermocouples and their reliability in particularly hard operating conditions. An element of response is provided to the problem of W/Re thermocouple drift under neutron flux by defining the new thermocouple Mo 5% Nb/Nb 10% Mo which, because of the low capture cross section of thermoelectric elements, gives one reason to hope for a less significant drift of these thermocouples under neutron flux than that found with W/Re thermocouples. Finally, determining the surface temperature of fuel element cladding with the Mo/Zircaloy thermocouple may prove worthwhile providing the temperatures do not exceed 1300 0 C and the electric insulator is aluminium oxide which up to 1300 0 C does not appear to react with thermoelectric wires [fr

  17. Measuring skin temperature before, during and after exercise: a comparison of thermocouples and infrared thermography

    International Nuclear Information System (INIS)

    Fernandes, Alex de Andrade; Amorim, Paulo Roberto dos Santos; De Moura, Anselmo Gomes; Moreira, Danilo Gomes; Costa, Carlos Magno Amaral; Marins, João Carlos Bouzas; Brito, Ciro José; Sillero-Quintana, Manuel

    2014-01-01

    Measuring skin temperature (T SK ) provides important information about the complex thermal control system and could be interesting when carrying out studies about thermoregulation. The most common method to record T SK  involves thermocouples at specific locations; however, the use of infrared thermal imaging (IRT) has increased. The two methods use different physical processes to measure T SK , and each has advantages and disadvantages. Therefore, the objective of this study was to compare the mean skin temperature (MT SK ) measurements using thermocouples and IRT in three different situations: pre-exercise, exercise and post-exercise. Analysis of the residual scores in Bland–Altman plots showed poor agreement between the MT SK  obtained using thermocouples and those using IRT. The averaged error was −0.75 °C during pre-exercise, 1.22 °C during exercise and −1.16 °C during post-exercise, and the reliability between the methods was low in the pre- (ICC = 0.75 [0.12 to 0.93]), during (ICC = 0.49 [−0.80 to 0.85]) and post-exercise (ICC = 0.35 [−1.22 to 0.81] conditions. Thus, there is poor correlation between the values of MT SK  measured by thermocouples and IRT pre-exercise, exercise and post-exercise, and low reliability between the two forms of measurement. (paper)

  18. Experiences with W3Re/W25Re thermocouples in fuel pins of NS Otto Hahn's two cores

    International Nuclear Information System (INIS)

    Kolb, M.

    1975-01-01

    Applications and performance of thermocouples in the Otto Hahn reactor are presented. The measurement of effective thermocouple time constants and of fuel rod heat transfer time constants utilizing the reactor noise and the resulting small temperature fluctuations which has become practical by the advent of modern noise analysis systems, is dealt with

  19. Recent improvements on micro-thermocouple based SThM

    OpenAIRE

    Nguyen, T. P.; Thiery, L.; Teyssieux, D.; Briand, Danick; Vairac, P.

    2017-01-01

    The scanning thermal microscope (SThM) has become a versatile tool for local surface temperature mapping or measuring thermal properties of solid materials. In this article, we present recent improvements in a SThM system, based on a micro-wire thermocouple probe associated with a quartz tuning fork for contact strength detection. Some results obtained on an electrothermal micro-hotplate device, operated in active and passive modes, allow demonstrating its performance as a coupled force detec...

  20. The influence of lead temperature on the accuracy of various stainless-steel sheathed, mineral-inulated nickel-chromium/nickel aluminium thermocouples

    International Nuclear Information System (INIS)

    Burnett, P.; Burns, J.S.

    1977-10-01

    Samples of three types of stainless steel sheathed MI thermocouples, such as are currently used in fire and furnace tests of transport flasks, have been subjected to high lead temperatures whilst the thermojunctions were kept at a constant low temperature. Both the lead temperature and the length of lead at temperature have been varied. As the lead temperature rises from ambient to a selected value, the emf output from the thermocouple initially decreases and then increases, taking up a final value dependent on the particular conditions. Below a threshold lead temperature, no significant steady state error occurs and the negative transient is generally negligible. Each thermocouple has its own threshold temperature, the lowest found being about 600 0 C, although the average lies at about 750 0 C. Above the threshold lead temperature, the thermal emf can be in error by the equivalent of more than 100 0 C, the highest error found being nearly 230 0 C at a temperature 250 0 C above threshold. The same thermocouple showed a negative transient of 13 0 C 3 minutes after start of heating to 890 0 C. It is probable that the steady state error arises because of the degradation of the thermocouple mineral insulation at elevated temperatures and recommendations are made on the use of such thermocouples in fire and furnace tests. The cause of the initial negative transient error has not been identified, but ways of minimising any resultant errors are suggested. (author)

  1. Heated junction thermocouple level measurement apparatus

    International Nuclear Information System (INIS)

    Bevilacqua, F.; Burger, J.M.

    1984-01-01

    A liquid level sensing apparatus senses the level of liquid surrounding the apparatus. A plurality of axially spaced sensors are enclosed in a separator tube. The separator tube tends to collapse the level of a two-phase fluid within the separator tube into essentially a liquid phase and a gaseous phase where the collapsed level bears a relationship to the coolant inventory outside the separator tube. The level of the liquid phase is sensed by level sensing apparatus. The separator tube contains inlet-outlet ports near the top and bottom thereof to equalize the liquid level inside and outside the separator tube when the level fluctuates or the water within the separator tube flashes to steam. Each sensor is comprised of a heater, a heated thermocouple junction and an unheated thermocouple junction within an elongated heat conductive housing. The heated portion of housing is enclosed in a splash guard with inlet-outlet ports near the top and bottom to equalize the liquid level inside and outside the splash guardand to eliminate the spurious indications of liquid level change which may arise if water droplets contact the housing in the region of the heater. To prevent steam bubbles entrained in a two-phase fluid cross flow from entering the lateral inlet-outlet ports of the separator tube, the separator tube is enclosed in support tube which may in turn be enclosed in an otherwise unused control element assembly shroud. The lateral inlet-outlet ports of separator tube are axially offset from lateral inlet-outlet ports of support tube at least where support tube is subjected to cross flow. The shroud is open on the bottom and has lateral inlet-outlet ports to facilitate liquid level fluctuations to equalize inside and outside shroud

  2. Proposed algorithm for determining the delta intercept of a thermocouple psychrometer curve

    International Nuclear Information System (INIS)

    Kurzmack, M.A.

    1993-01-01

    The USGS Hydrologic Investigations Program is currently developing instrumentation to study the unsaturated zone at Yucca Mountain in Nevada. Surface-based boreholes up to 2,500 feet in depth will be drilled, and then instrumented in order to define the water potential field within the unsaturated zone. Thermocouple psychrometers will be used to monitor the in-situ water potential. An algorithm is proposed for simply and efficiently reducing a six wire thermocouple psychrometer voltage output curve to a single value, the delta intercept. The algorithm identifies a plateau region in the psychrometer curve and extrapolates a linear regression back to the initial start of relaxation. When properly conditioned for the measurements being made, the algorithm results in reasonable results even with incomplete or noisy psychrometer curves over a 1 to 60 bar range

  3. Recent improvements on micro-thermocouple based SThM

    Science.gov (United States)

    Nguyen, TP; Thiery, L.; Teyssieux, D.; Briand, D.; Vairac, P.

    2017-01-01

    The scanning thermal microscope (SThM) has become a versatile tool for local surface temperature mapping or measuring thermal properties of solid materials. In this article, we present recent improvements in a SThM system, based on a micro-wire thermocouple probe associated with a quartz tuning fork for contact strength detection. Some results obtained on an electrothermal micro-hotplate device, operated in active and passive modes, allow demonstrating its performance as a coupled force detection and thermal measurement system.

  4. R and D advances in high temperature thermocouples for nuclear utilization in severe environment

    International Nuclear Information System (INIS)

    Schley, R.; Blanc, J.Y.

    1985-01-01

    Safety experiments for water reactors in Cadarache have made necessary a research program for developing special thermocopules for use in severe fuel damage conditions (superheated steam). Standard cladding thermocouples (type K, alumina insulated, zircaloy sheathed, O.D. 0.7 mm) must be replaced by others with W3Re versus W25Re legs, Ta sheath protected by a zircaloy outer sheath, and hafnia or thoria insulation. The zircaloy sheath will be sufficient to protect correctly tantalum. Fuel centerline thermocouples have W5Re versus W26Re or W3Re versus W25Re legs, hard-fired thoria insulation and rhenium CVD sheath (O.D. 1.1 mm). A protective ReSi/sub 2/ coating is applied. This protection withstands at least 1600 0 C, 45 minutes in steam. Tests are done concerning: (a) materials compatibilities in helium between 1400 0 C and 2000 0 C, (b) prototypes qualification (In Saclay or Grenoble), (c) determination of errors due to degradation of insulation resistance of thermocouples cables (with magnesia, hafnia, alumina), (d) Ir or Re protective coatings by CVD process, other coatings by ionic bombardment, etc...A completely new type of hot junction has been patented

  5. Thermocouple placement and hot spots in radioactive waste tanks

    International Nuclear Information System (INIS)

    Barker, J.J.

    1991-06-01

    Analytical solutions available in Carslaw and Jaeger's Conduction of Heat in Solids for continuous point sources and for continuous finite sources are used to demonstrate that placement of thermocouples on a fine enough grid to detect a hot spot is impracticable for existing waste tanks but fortunately not necessary. Graphs covering ranges of diffusivities, times, temperatures and heat generation rates are included. 2 refs., 8 figs., 5 tabs

  6. Attachment of Free Filament Thermocouples for Temperature Measurements on Ceramic Matrix Composites

    Science.gov (United States)

    Lei, Jih-Fen; Cuy, Michael D.; Wnuk, Stephen P.

    1998-01-01

    At the NASA Lewis Research Center, a new installation technique utilizing convoluted wire thermocouples (TC's) was developed and proven to produce very good adhesion on CMC's, even in a burner rig environment. Because of their unique convoluted design, such TC's of various types and sizes adhere to flat or curved CMC specimens with no sign of delamination, open circuits, or interactions-even after testing in a Mach 0.3 burner rig to 1200 C (2200 F) for several thermal cycles and at several hours at high temperatures. Large differences in thermal expansion between metal thermocouples and low-expansion materials, such as CMC's, normally generate large stresses in the wires. These stresses cause straight wires to detach, but convoluted wires that are bonded with strips of coating allow bending in the unbonded portion to relieve these expansion stresses.

  7. Thermocouples used in emission systems of internal combustion engines; Thermoelemente fuer den Einsatz in Abgassystemen von Verbrennungsmotoren

    Energy Technology Data Exchange (ETDEWEB)

    Augustin, Silke; Froehlich, Thomas; Mammen, Helge [Technische Univ. Illmenau (Germany). Inst. fuer Prozessmess- und Sensortechnik; Ament, Christoph; Guether, Thomas [Technische Univ. Illmenau (Germany). Inst. fuer Automatisierungs- und Systemtechnik

    2012-11-01

    Thermocouples used in exhaust systems of combustion engines are exposed to high temperature gradients and temperature leaps ({Delta}T > 900 K), high flow speeds and pressure. When constructing these thermocouples, a compromise is needed between the resulting high demands on the mechanical-thermal stability, accuracy and the fast response time demanded by the servo-control of the motors. Additionally, a numerical correction of the measured signal may contribute to an improved sensor dynamics. (orig.)

  8. AGR-1 Thermocouple Data Analysis

    International Nuclear Information System (INIS)

    Einerson, Jeff

    2012-01-01

    This report documents an effort to analyze measured and simulated data obtained in the Advanced Gas Reactor (AGR) fuel irradiation test program conducted in the INL's Advanced Test Reactor (ATR) to support the Next Generation Nuclear Plant (NGNP) R and D program. The work follows up on a previous study (Pham and Einerson, 2010), in which statistical analysis methods were applied for AGR-1 thermocouple data qualification. The present work exercises the idea that, while recognizing uncertainties inherent in physics and thermal simulations of the AGR-1 test, results of the numerical simulations can be used in combination with the statistical analysis methods to further improve qualification of measured data. Additionally, the combined analysis of measured and simulation data can generate insights about simulation model uncertainty that can be useful for model improvement. This report also describes an experimental control procedure to maintain fuel target temperature in the future AGR tests using regression relationships that include simulation results. The report is organized into four chapters. Chapter 1 introduces the AGR Fuel Development and Qualification program, AGR-1 test configuration and test procedure, overview of AGR-1 measured data, and overview of physics and thermal simulation, including modeling assumptions and uncertainties. A brief summary of statistical analysis methods developed in (Pham and Einerson 2010) for AGR-1 measured data qualification within NGNP Data Management and Analysis System (NDMAS) is also included for completeness. Chapters 2-3 describe and discuss cases, in which the combined use of experimental and simulation data is realized. A set of issues associated with measurement and modeling uncertainties resulted from the combined analysis are identified. This includes demonstration that such a combined analysis led to important insights for reducing uncertainty in presentation of AGR-1 measured data (Chapter 2) and interpretation of

  9. AGR-1 Thermocouple Data Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Jeff Einerson

    2012-05-01

    This report documents an effort to analyze measured and simulated data obtained in the Advanced Gas Reactor (AGR) fuel irradiation test program conducted in the INL's Advanced Test Reactor (ATR) to support the Next Generation Nuclear Plant (NGNP) R&D program. The work follows up on a previous study (Pham and Einerson, 2010), in which statistical analysis methods were applied for AGR-1 thermocouple data qualification. The present work exercises the idea that, while recognizing uncertainties inherent in physics and thermal simulations of the AGR-1 test, results of the numerical simulations can be used in combination with the statistical analysis methods to further improve qualification of measured data. Additionally, the combined analysis of measured and simulation data can generate insights about simulation model uncertainty that can be useful for model improvement. This report also describes an experimental control procedure to maintain fuel target temperature in the future AGR tests using regression relationships that include simulation results. The report is organized into four chapters. Chapter 1 introduces the AGR Fuel Development and Qualification program, AGR-1 test configuration and test procedure, overview of AGR-1 measured data, and overview of physics and thermal simulation, including modeling assumptions and uncertainties. A brief summary of statistical analysis methods developed in (Pham and Einerson 2010) for AGR-1 measured data qualification within NGNP Data Management and Analysis System (NDMAS) is also included for completeness. Chapters 2-3 describe and discuss cases, in which the combined use of experimental and simulation data is realized. A set of issues associated with measurement and modeling uncertainties resulted from the combined analysis are identified. This includes demonstration that such a combined analysis led to important insights for reducing uncertainty in presentation of AGR-1 measured data (Chapter 2) and interpretation of

  10. INFLUENCE OF REOXIDATION ON SILICA-CONTAINING BARIUM TITANATE CERAMICS FOR PTCR THERMISTORS PREPARED BY TAPE CASTING

    Directory of Open Access Journals (Sweden)

    Jianqiao Liu

    2016-03-01

    Full Text Available Silica-containing barium-rich BaTiO₃ ceramics for thermistors with a positive temperature coefficient of resistance are prepared by a tape-casting technique. The ceramics are sintered in a reducing atmosphere at low temperatures of 1175-1225°C. The influences of reoxidation are investigated after the reduced ceramics are reoxidized in air at 700-900°C. An anomalous correlation is illustrated between room temperature resistivity and reoxidation temperature. The anomaly results from the ferroelectricity rebuilding mechanism, which includes the spontaneous polarization theory and the ferroelectricity degradation caused by oxygen vacancies. The acceptor-state densities are estimated from the temperature-dependent resistivity. A critical temperature of 750-800°C is concluded for the grain boundary reoxidation.

  11. Temperature sensor realized by inkjet printing process on flexible substrate

    International Nuclear Information System (INIS)

    Dankoco, M.D.; Tesfay, G.Y.; Benevent, E.; Bendahan, M.

    2016-01-01

    Highlights: • Flexible temperature sensor was realized by inkjet printing process on Kapton substrate. • The jetting parameters were optimized to obtain evenly distributed silver coating layers and a large meander forming the sensor. • The Temperature sensor studied offers a good sensitivity, a good linearity and less than 5% hysteresis in extended measurement in the range of 20–60 °C. - Abstract: The objective of this study is to realize a printed and flexible temperature sensor to achieve surface temperature measurement of the human body. The sensor is a thermistor composed silver (Ag) deposited on a Polyimide substrate (Kapton HN). The meander was patterned by inkjet printing with a drop-on-demand Jetlab4 (Microfab Technologies Inc.). The resistance temperature coefficients have been studied in the temperature range of 20–60 °C with a range of voltage between 0 and 1 V. The stability versus time has also been measured without a sensor layer protection. The sensitive area of the sensor, silver lines width and the gap between the electrical conductors were, respectively 6.2 cm 2 , 300 μm, 60 μm. The mean temperature sensor sensitivity found was 2.23 × 10 −3 °C −1 . The results show a good linearity and less than 5% hysteresis in the extended measurement.

  12. Experience with W3Re/W25Re thermocouples in fuel pins of NS Otto Hahn's two cores

    International Nuclear Information System (INIS)

    Kolb, M.

    1976-01-01

    The paper first deals with the installation of 18 and 9 high-temperature sheathed thermocouples in fuel rods of the cores FDR-1 and FDR-2, respectively. The measured fuel rod centerline temperatures could be related to the local linear rod power at any given time by means of the densities of fission products with different half-lives obtained from fuel rod γ-scans. The fuel temperatures show then already an increase with the burn-up of the FDR-1 which becomes steeper when taking into account the decrease of the EMF measured at irradiated thermocouples taken from the fuel rods. Finally, the determination of effective thermocouple time constants and of fuel rod heat transfer time constants is demonstrated by utilizing the reactor noise to measure the transfer function between neutron flux and fuel temperature signal. (orig.) [de

  13. Calibration of the Dodewaard downcomer thermocouple cross-correlation flow-rate measurements

    Energy Technology Data Exchange (ETDEWEB)

    Stekelenburg, A J.C. [Technische Univ. Delft (Netherlands). Interfacultair Reactor Inst.; Hagen, T.H.J.J. van der [Technische Univ. Delft (Netherlands). Interfacultair Reactor Inst.; Akker, H.E.A. van den [Technische Univ. Delft (Netherlands). Lab. voor Fysische Technologie

    1992-12-01

    The cross-correlation flow measurement technique, applied for measuring the coolant flow rate in a nuclear reactor, was calibrated with the use of numerical simulations of turbulent flow. The three-dimensional domain was collapsed into two dimensions. With a two-dimensional calculation of steady-state flow with transient thermal characteristics the response of thermocouples to a temperature variation was calculated. By cross-correlating the calculated thermocouple responses, the link between total flow rate and measured transit times was made. Three calibration points were taken in the range of 579 kg/s to 1477 kg/s. In this range, the product of the calculated transit time and the mass flow-rate is constant up to +3.5% and -2.4%. The reliability of the calibration was estimated at {+-}4.6%. The influence of the inlet boundary conditions, and the modelling of the flow in the upper part of the downcomer channel on the calibration result is shown to be small. A measured velocity profile effect was successfully predicted. (orig.).

  14. Recommendations for the specification of thermocouples for nuclear applications

    International Nuclear Information System (INIS)

    1977-05-01

    This Code of Practice is a guide for use in the preparation of individual specifications to cover, as fully as possible the conditions governing the supply of raw materials and the ordering, manufacture, testing, inspection, handling and installation of thermocouples for use in nuclear environments in order that reliable, consistent and generally acceptable results can be obtained. The insulation resistance values quoted in this document apply to magnesium oxide. If other insulants are called for, appropriate values must be specified. (author)

  15. Use of indexed sensitivity factors in the analysis of nickel and iron based alloys: study of the decalibration of sheathed Chromel/Alumel thermocouples

    International Nuclear Information System (INIS)

    Christie, W.H.

    1978-01-01

    Sheathed Chromel versus Alumel thermocouples decalibrate when exposed to temperatures in excess of 1100 0 C. Thermocouples sheathed in Inconel-600 and type 304 stainless steel were studied in this work. Quantified SIMS data showed that the observed decalibrations were due to significant alterations that took place in the Chromel and Alumel thermoelements. The amount of alteration was different for each thermocouple and was influenced by the particular sheath material used in the thermocouple construction. Relative sensitivity factors, indexed by a matrix ion species ratio, were used to quantify SIMS data for three nickel-based alloys, Chromel, Alumel, and Inconel-600, and an iron-based alloy, type 304 stainless steel. Oxygen pressure >2 x 10 -6 torr in the sputtering region gave enhanced sensitivity and superior quantitative results as compared to data obtained at instrumental residual pressure

  16. Computer subroutines to aid analysis of experimental data from thermocouples and pressure transducers

    International Nuclear Information System (INIS)

    Durham, M.E.

    1976-08-01

    Three subroutines (CALSET, CALBR8 and PTRCAL) have been written to provide a convenient system for converting experimental measurements obtained from thermocouples and pressure transducers to temperatures and pressures. The method of operation and the application of the subroutines are described. (author)

  17. Measurement errors for thermocouples attached to thin plates

    International Nuclear Information System (INIS)

    Sobolik, K.B.; Keltner, N.R.; Beck, J.V.

    1989-01-01

    This paper discusses Unsteady Surface Element (USE) methods which are applied to a model of a thermocouple wire attached to a thin disk. Green's functions are used to develop the integral equations for the wire and the disk. The model can be used to evaluate transient and steady state responses for many types of heat flux measurement devices including thin skin calorimeters and circular foil (Gardon) head flux gauges. The model can accommodate either surface or volumetric heating of the disk. The boundary condition at the outer radius of the disk can be either insulated or constant temperature. Effect on the errors of geometrical and thermal factors can be assessed. Examples are given

  18. Detection of thermocouple malfunction in the Beacon system

    International Nuclear Information System (INIS)

    Morita, T.; Heibel, M.D.; Congedo, T.V.

    1992-01-01

    The BEACON system uses Core Exit Thermocouples (T/C) extensively for continuous radial power distribution monitoring. The T/C's are used to adjust the reference power distribution generated by the BEACON system to match the current radial power distribution. T/C reliability, repeatability, and relative accuracy have been very satisfactory. However, it is very important to detect any T/C malfunctions during operation, since a T/C signal change caused by an undetected malfunction can lead to serious errors in the radial power distribution developed by BEACON. A simple procedure has been developed which is capable of discriminating between changes in T/C signals caused by actual changes in reactor conditions and signal changes caused by T/C malfunctions

  19. Temperature profile data collected using current meter, mooring, thermistor casts from the Atlantic Ocean in part of the International Decade of Ocean Exploration / Mid-Ocean Dynamics Experiment from 11 March 1973 to 01 July 1973 (NODC Accession 7700106)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Temperature data were collected using current meter, mooring, thermistor casts from March 11, 1973 to July 1, 1973. Data were submitted by Woods Hole Oceanographic...

  20. New fixed-point mini-cell to investigate thermocouple drift in a high-temperature environment under neutron irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Laurie, M.; Vlahovic, L.; Rondinella, V.V. [European Commission, Joint Research Centre, Institute for Transuranium Elements, P.O. Box 2340, D-76125 Karlsruhe, (Germany); Sadli, M.; Failleau, G. [Laboratoire Commun de Metrologie, LNE-Cnam, Saint-Denis, (France); Fuetterer, M.; Lapetite, J.M. [European Commission, Joint Research Centre, Institute for Energy and Transport, P.O. Box 2, NL-1755 ZG Petten, (Netherlands); Fourrez, S. [Thermocoax, 8 rue du pre neuf, F-61100 St Georges des Groseillers, (France)

    2015-07-01

    Temperature measurements in the nuclear field require a high degree of reliability and accuracy. Despite their sheathed form, thermocouples subjected to nuclear radiations undergo changes due to radiation damage and transmutation that lead to significant EMF drift during long-term fuel irradiation experiment. For the purpose of a High Temperature Reactor fuel irradiation to take place in the High Flux Reactor Petten, a dedicated fixed-point cell was jointly developed by LNE-Cnam and JRC-IET. The developed cell to be housed in the irradiation rig was tailor made to quantify the thermocouple drift during the irradiation (about two year duration) and withstand high temperature (in the range 950 deg. C - 1100 deg. C) in the presence of contaminated helium in a graphite environment. Considering the different levels of temperature achieved in the irradiation facility and the large palette of thermocouple types aimed at surveying the HTR fuel pebble during the qualification test both copper (1084.62 deg. C) and gold (1064.18 deg. C) fixed-point materials were considered. The aim of this paper is to first describe the fixed-point mini-cell designed to be embedded in the reactor rig and to discuss the preliminary results achieved during some out of pile tests as much as some robustness tests representative of the reactor scram scenarios. (authors)

  1. External attachment of titanium sheathed thermocouples to zirconium nuclear fuel rods for the LOFT reactor

    International Nuclear Information System (INIS)

    Welty, R.K.

    1980-01-01

    The Exxon Nuclear Company, Inc., acting as a Subcontractor to EG and G Idaho Inc., Idaho National Engineering Laboratory, Idaho Falls, Idaho, has developed a welding process to attach titanium sheathed thermocouples to the outside of the zircaloy clad fuel rods. The fuel rods and thermocouples are used to test simulated loss-of-coolant accident (LOCA) conditions in a pressurized water reactor (LOFT Reactor, Idaho National Laboratory). A laser beam was selected as the optimum welding process because of the extremely high energy input per unit volume that can be achieved allowing local fusion of a small area irrespective of the difference in material thickness to be joined. A commercial pulsed laser and energy control system was installed along with specialized welding fixtures. Laser room facility requirements and tolerances were established. Performance qualifications, and detailed welding procedures were also developed. Product performance tests were conducted to assure that engineering design requirements could be met on a production basis

  2. The Combined Use of a Gas-Controlled Heat Pipe and a Copper Point to Improve the Calibration of Thermocouples up to 1100 ˚C

    Science.gov (United States)

    Astrua, M.; Iacomini, L.; Battuello, M.

    2008-10-01

    The calibration of platinum-based thermocouples from 420 °C to 1,100 ˚C is currently carried out at INRIM making use of two different apparatus: for temperatures below 930 ˚C, a potassium gas-controlled heat pipe (GCHP) is used, whereas a metal-block furnace is adopted for higher temperatures. The standard uncertainty of the reference temperature obtained in the lower temperature range is almost one order of magnitude better than in the higher temperature range. A sealed copper cell was investigated to see if it could be used to calibrate thermocouples above 930 ˚C with a lower uncertainty than our current procedures allowed. The cell was characterized with Type S and Pt/Pd thermocouples and with an HTPRT. The freezing plateaux were flat within 0.01 ˚C and lasted up to 1 h with a repeatability of 0.02 ˚C. The temperature of the cell was determined with a standard uncertainty of 0.04 ˚C. Hence, the copper cell was found to be superior to the comparator furnace for the calibration of platinum-based thermocouples because of the significant decrease in the uncertainty that it provides. An analysis was also carried out on the calibration of Pt/Pd thermocouples, and it was found that the combined use of the potassium GCHP and the Cu fixed-point cell is adequate to exploit the potential of these sensors in the range from 420 °C to 1,084 °C. A comparison with a fixed-point calibration was also made which gave rise to agreement within 0.07 ˚C between the two approaches.

  3. Comparative evaluation of corrosion behaviour of type K thin film thermocouple and its bulk counterpart

    International Nuclear Information System (INIS)

    Mukherjee, S.K.; Barhai, P.K.; Srikanth, S.

    2011-01-01

    Highlights: → Anodic vacuum arc deposited chromel and alumel films are more 'noble' in 5% NaCl solution than their respective wires. → Chromel undergoes localised corrosion while alumel shows uniform corrosion. → Virgin samples of chromel-alumel TFTCs exhibit good thermoelectric response. → Their thermoelectric outputs remain largely unaffected when shelved under normal atmospheric conditions. → After 288 h of exposure in salt spray environment, their thermoelectric outputs show noticeable change due to size effects. - Abstract: This paper investigates the corrosion behaviour of type K thermoelements and their thin films, and compares the performance of chromel-alumel thin film thermocouple with its wire counterpart before and after exposure to 5% NaCl medium. Potentiodynamic polarisation tests reveal that chromel and alumel films are more 'noble' than their respective wires. Alumel corrodes faster when coupled with chromel in films than as wires. Secondary electron micrographs and electrochemical impedance spectroscopy measurements suggest that chromel shows localised corrosion while alumel undergoes uniform corrosion. Corrosion adversely affects the thermocouple output and introduces an uncertainty in the measurement.

  4. A Simple Test to Evaluate the Calibration Stability and Accuracy of Infrared Thermocouple Sensors

    OpenAIRE

    Pinnock, Derek R.; Bugbee, Bruce

    2002-01-01

    Accurately measuring surface temperature is not difficult when the surface, the sensor, and air temperatures are similar, but it is challenging when the surface temperature is significantly different than air and sensor temperatures. We tested three Infrared Thermocouple sensors (IRT’s) that had been used for two years in a greenhouse environment. The importance of the correction for sensor body temperature was also examined.

  5. An Explicit Approach Toward Modeling Thermo-Coupled Deformation Behaviors of SMPs

    Directory of Open Access Journals (Sweden)

    Hao Li

    2017-03-01

    Full Text Available A new elastoplastic J 2 -flow models with thermal effects is proposed toward simulating thermo-coupled finite deformation behaviors of shape memory polymers. In this new model, an elastic potential evolving with development of plastic flow is incorporated to characterize the stress-softening effect at unloading and, moreover, thermo-induced plastic flow is introduced to represent the strain recovery effect at heating. It is shown that any given test data for both effects may be accurately simulated by means of direct and explicit procedures. Numerical examples for model predictions compare well with test data in literature.

  6. Development of Mechanical Sealing and Laser Welding Technology to Instrument Thermocouple for Nuclear Fuel Test Rod

    Energy Technology Data Exchange (ETDEWEB)

    Joung, Chang-Young; Ahn, Sung-Ho; Hong, Jin-Tae; Kim, Ka-Hye; Huh, Sung-Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    Zircaloy-4 of the nuclear fuel test rod, AISI 316L of the mechanical sealing parts, and the MI (mineral insulated) cable at a thermocouple instrumentation are hetero-metals, and are difficult to weld to dissimilar materials. Therefore, a mechanical sealing method to instrument the thermocouple should be conducted using two kinds of sealing process as follows: One is a mechanical sealing process using Swagelok, which is composed of sealing components that consists of an end-cap, a seal tube, a compression ring and a Swagelok nut. The other is a laser welding process used to join a seal tube, and an MI cable, which are made of the same material. The mechanical sealing process should be sealed up with the mechanical contact compressed by the strength forced between a seal tube and an end-cap, and the laser welding process should be conducted to have no defects on the sealing area between a seal tube and an MI cable. Therefore, the mechanical sealing and laser welding techniques need to be developed to accurately measure the centerline temperature of the nuclear fuel test rod in an experimental reactor. The mechanical sealing and laser welding tests were conducted to develop the thermocouple instrumentation techniques for the nuclear fuel test rod. The optimum torque value of a Swagelok nut to seal the mechanical sealing part between the end-cap and seal tube was established through various torque tests using a torque wrench. The optimum laser welding conditions to seal the welding part between a seal tube and an MI cable were obtained through various welding tests using a laser welding system.

  7. Development of Mechanical Sealing and Laser Welding Technology to Instrument Thermocouple for Nuclear Fuel Test Rod

    International Nuclear Information System (INIS)

    Joung, Chang-Young; Ahn, Sung-Ho; Hong, Jin-Tae; Kim, Ka-Hye; Huh, Sung-Ho

    2015-01-01

    Zircaloy-4 of the nuclear fuel test rod, AISI 316L of the mechanical sealing parts, and the MI (mineral insulated) cable at a thermocouple instrumentation are hetero-metals, and are difficult to weld to dissimilar materials. Therefore, a mechanical sealing method to instrument the thermocouple should be conducted using two kinds of sealing process as follows: One is a mechanical sealing process using Swagelok, which is composed of sealing components that consists of an end-cap, a seal tube, a compression ring and a Swagelok nut. The other is a laser welding process used to join a seal tube, and an MI cable, which are made of the same material. The mechanical sealing process should be sealed up with the mechanical contact compressed by the strength forced between a seal tube and an end-cap, and the laser welding process should be conducted to have no defects on the sealing area between a seal tube and an MI cable. Therefore, the mechanical sealing and laser welding techniques need to be developed to accurately measure the centerline temperature of the nuclear fuel test rod in an experimental reactor. The mechanical sealing and laser welding tests were conducted to develop the thermocouple instrumentation techniques for the nuclear fuel test rod. The optimum torque value of a Swagelok nut to seal the mechanical sealing part between the end-cap and seal tube was established through various torque tests using a torque wrench. The optimum laser welding conditions to seal the welding part between a seal tube and an MI cable were obtained through various welding tests using a laser welding system

  8. External attachment of titanium sheathed thermocouples to zirconium nuclear fuel rods for the loss-of-fluid-test (LOFT) Reactor

    International Nuclear Information System (INIS)

    Welty, R.K.

    1980-01-01

    A welding process to attach titanium sheathed thermocouples to the outside of the zircaloy clad fuel rods has been developed. A laser beam was selected as the optimum welding process because of the extremely high energy input per unit volume that can be achieved allowing local fusion of a small area irrespective of the difference in material thickness to be joined. Irradiation tests showed no degradation of thermocouples or weld structure. Fast thermal cycle and heater rod blowdown reflood tests were made to subject the weldments to high temperatures, high pressure steam, and fast water quench cycles. From the behavior of these tests, it was concluded that the attachment welds would survive a series of reactor safety tests. 2 refs

  9. Nuclear Power Plant Thermocouple Sensor-Fault Detection and Classification Using Deep Learning and Generalized Likelihood Ratio Test

    Science.gov (United States)

    Mandal, Shyamapada; Santhi, B.; Sridhar, S.; Vinolia, K.; Swaminathan, P.

    2017-06-01

    In this paper, an online fault detection and classification method is proposed for thermocouples used in nuclear power plants. In the proposed method, the fault data are detected by the classification method, which classifies the fault data from the normal data. Deep belief network (DBN), a technique for deep learning, is applied to classify the fault data. The DBN has a multilayer feature extraction scheme, which is highly sensitive to a small variation of data. Since the classification method is unable to detect the faulty sensor; therefore, a technique is proposed to identify the faulty sensor from the fault data. Finally, the composite statistical hypothesis test, namely generalized likelihood ratio test, is applied to compute the fault pattern of the faulty sensor signal based on the magnitude of the fault. The performance of the proposed method is validated by field data obtained from thermocouple sensors of the fast breeder test reactor.

  10. Design and research of seal structure for thermocouple column assembly

    International Nuclear Information System (INIS)

    Rao Qiqi; Li Na; Zhao Wei; Ma Zhigang

    2015-01-01

    The new seal structure was designed to satisfy the function of thermocouple column assembly and the reactor structure. This seal structure uses the packing graphite ring and adopts the self-sealing principle. Cone angle is brought to the seal face of seal structure which is conveniently to assembly and disassembly. After the sealing principle analysis and stress calculation of graphite ring which adopt the cone angle, the cone angle increases the radial force of seal structure and improves the seal effect. The stress analysis result shows the seal structure strength satisfies the regulation requirement. The cold and hot function test results shows the sealing effect is good, and the design requirement is satisfied. (authors)

  11. LOFT ECC Pitot Tube and Thermocouple Rake Penetration thermal analysis

    International Nuclear Information System (INIS)

    Tolan, B.J.

    1977-01-01

    A thermal analysis of the LOFT ECC Pitot Tube and Thermocouple Rake Penetration was performed using COUPLE, a two-dimensional finite element computer code. Four transients which conservatively cover all transients the rake will be exposed to were included in this analysis in order to comply with the ASME Code Section III requirements. The transients conservatively cover hot and cold leg operation, and nuclear and nonnuclear operation. The four transients include the LOCE with ECC injection transient, the single control rod drop transient, the scram transient, and the heatup with 0 to 100% load change transient. Temperature distributions in the rake were obtained for each of the four transients and several plots of node temperatures vs. time are given

  12. Internal attachment of laser beam welded stainless steel sheathed thermocouples into stainless steel upper end caps in nuclear fuel rods for the LOFT Reactor

    International Nuclear Information System (INIS)

    Welty, R.K.; Reid, R.D.

    1980-01-01

    The Exxon Nuclear Company, Inc., acting as a subcontractor to EG and G Idaho Inc., Idaho National Engineering Laboratory, Idaho Falls, Idaho, conducted a laser beam welding study to attach internal stainless steel thermocouples into stainless steel upper end caps in nuclear fuel rods. The objective of this study was to determine the feasibility of laser welding a single 0.063 inch diameter stainless steel (304) sheathed thermocouple into a stainless steel (316) upper end cap for nuclear fuel rods. A laser beam was selected because of the extremely high energy input in unit volume that can be achieved allowing local fusion of a small area irrespective of the difference in material thickness to be joined. A special weld fixture was designed and fabricated to hold the end cap and the thermocouple with angular and rotational adjustment under the laser beam. A commercial pulsed laser and energy control system was used to make the welds

  13. Investigating Microbial Habitats in Hydrothermal Chimneys using Ti-Thermocouple Arrays: Microbial Diversity

    Science.gov (United States)

    Pagé, A.; Tivey, M. K.; Stakes, D. S.; Bradley, A. M.; Seewald, J. S.; Wheat, C. G.; Reysenbach, A.

    2004-12-01

    In order to examine the changes that occur in the microbial community composition as a deep-sea hydrothermal vent chimney develops, we deployed Ti-thermocouple arrays over high temperature vents at two active sites of the Guaymas Basin Southern Trough. Chimney material that precipitated around the arrays was recovered after 4 and 72 days. Chimney material that precipitated prior to deployment of the arrays was also recovered at one of the sites (Busted Shroom). Culture-independent analysis based on the small subunit rRNA sequence (cloning and DGGE) was used to determine the microbial diversity associated with subsamples of each chimney. The original Busted Shroom chimney (BSO) was dominated by members of the Crenarchaeota Marine Group I, a group of cosmopolitan marine Archaea, ɛ -Proteobacteria, and γ -Proteobacteria, two divisions of Bacteria that are common to deep-sea vents. The 4 days old Busted Shroom chimney (BSD1) was dominated by members of the Methanocaldococcaceae, hyperthermophilic methanogens, and the 72 days old chimney (BSD2) by members of the Methanosarcinaceae, mesophilic and thermophilic methanogens. At the second site, Toadstool, the 72 days old chimney material that had precipitated around the array (TS) revealed the dominance of sequences from uncultured marine Archaea, the DHVE group I and II, and from the ɛ -Proteobacteria. Additionally, sequences belonging to the Methanocaldococcaceae and Desulfurococcaceae were recovered next to thermocouples that were at temperatures of 109° C (at Busted Shroom) and 116° C (at Toadstool), respectively. These temperatures are higher than the upper limit for growth of cultured representatives from each family.

  14. Low-noise audio amplifiers and preamplifier for use with intrinsic thermocouples

    International Nuclear Information System (INIS)

    Langner, G.C.; Sachs, R.D.; Stewart, F.L.

    1979-03-01

    Two simple, low-noise audio amplifiers and one low-noise preamplifier for use with intrinsic thermocouples were designed, built, and tested. The amplifiers and the preamplifier have different front end designs. One amplifier uses ultralow-noise operational amplifiers; the other amplifier uses a hybrid component. The preamplifier uses ultralow-noise discrete components. The amplifiers' equivalent noise inputs, at maximum gain, are 4.09 nV and 50 nV; the preamplifier's input is 4.05 μV. Their bandwidths are 15 600 Hz, 550 Hz, and 174 kHz, respectively. the amplifiers' equivalent noise inputs were measured from approx. 0 to 100 Hz, whereas the preamplifier's equivalent noise input was measured from approx. 0 to 174 kHz

  15. The effect of loading time on flexible pavement dynamic response: a finite element analysis

    Science.gov (United States)

    Yin, Hao; Solaimanian, Mansour; Kumar, Tanmay; Stoffels, Shelley

    2007-12-01

    Dynamic response of asphalt concrete (AC) pavements under moving load is a key component for accurate prediction of flexible pavement performance. The time and temperature dependency of AC materials calls for utilizing advanced material characterization and mechanistic theories, such as viscoelasticity and stress/strain analysis. In layered elastic analysis, as implemented in the new Mechanistic-Empirical Pavement Design Guide (MEPDG), the time dependency is accounted for by calculating the loading times at different AC layer depths. In this study, the time effect on pavement response was evaluated by means of the concept of “pseudo temperature.” With the pavement temperature measured from instrumented thermocouples, the time and temperature dependency of AC materials was integrated into one single factor, termed “effective temperature.” Via this effective temperature, pavement responses under a transient load were predicted through finite element analysis. In the finite element model, viscoelastic behavior of AC materials was characterized through relaxation moduli, while the layers with unbound granular material were assumed to be in an elastic mode. The analysis was conducted for two different AC mixtures in a simplified flexible pavement structure at two different seasons. Finite element analysis results reveal that the loading time has a more pronounced impact on pavement response in the summer for both asphalt types. The results indicate that for reasonable prediction of dynamic response in flexible pavements, the effect of the depth-dependent loading time on pavement temperature should be considered.

  16. Field installed brazed thermocouple feedthroughs for high vacuum experiments

    International Nuclear Information System (INIS)

    Anderson, P.; Messick, C.

    1983-01-01

    In order to reduce the occurrence of vacuum leaks and to increase the availability of the DIII vacuum vessel for experimental operation, effort was applied to developing a vacuum-tight brazed feedthrough system for sheathed thermocouples, stainless steel sheathed conductor cables and tubes for cooling fluids. This brazed technique is a replacement for elastomer ''O'' ring sealed feedthroughs that have proven vulnerable to leaks caused by thermal cycling, etc. To date, about 200 feedthroughs have been used. Up to 91 were grouped on a single conflat flange mounted in a bulkhead connector configuration which facilitates installation and removal. Investigation was required to select a suitable braze alloy, flux and installation procedure. Braze alloy selection was challenging since the alloy was required to have: 1) Melting temperature in excess of the 250 0 C (482 0 F) bakeout temperature. 2) No high vapor pressure elements. 3) Good wetting properties when used in air with acceptable flux. 4) Good wettability to 300 series stainless steel and inconel

  17. Application of flexible micro temperature sensor in oxidative steam reforming by a methanol micro reformer.

    Science.gov (United States)

    Lee, Chi-Yuan; Lee, Shuo-Jen; Shen, Chia-Chieh; Yeh, Chuin-Tih; Chang, Chi-Chung; Lo, Yi-Man

    2011-01-01

    Advances in fuel cell applications reflect the ability of reformers to produce hydrogen. This work presents a flexible micro temperature sensor that is fabricated based on micro-electro-mechanical systems (MEMS) technology and integrated into a flat micro methanol reformer to observe the conditions inside that reformer. The micro temperature sensor has higher accuracy and sensitivity than a conventionally adopted thermocouple. Despite various micro temperature sensor applications, integrated micro reformers are still relatively new. This work proposes a novel method for integrating micro methanol reformers and micro temperature sensors, subsequently increasing the methanol conversion rate and the hydrogen production rate by varying the fuel supply rate and the water/methanol ratio. Importantly, the proposed micro temperature sensor adequately controls the interior temperature during oxidative steam reforming of methanol (OSRM), with the relevant parameters optimized as well.

  18. Application of Flexible Micro Temperature Sensor in Oxidative Steam Reforming by a Methanol Micro Reformer

    Directory of Open Access Journals (Sweden)

    Yi-Man Lo

    2011-02-01

    Full Text Available Advances in fuel cell applications reflect the ability of reformers to produce hydrogen. This work presents a flexible micro temperature sensor that is fabricated based on micro-electro-mechanical systems (MEMS technology and integrated into a flat micro methanol reformer to observe the conditions inside that reformer. The micro temperature sensor has higher accuracy and sensitivity than a conventionally adopted thermocouple. Despite various micro temperature sensor applications, integrated micro reformers are still relatively new. This work proposes a novel method for integrating micro methanol reformers and micro temperature sensors, subsequently increasing the methanol conversion rate and the hydrogen production rate by varying the fuel supply rate and the water/methanol ratio. Importantly, the proposed micro temperature sensor adequately controls the interior temperature during oxidative steam reforming of methanol (OSRM, with the relevant parameters optimized as well.

  19. W-1 Sodium Loop Safety Facility experiment centerline fuel thermocouple performance

    International Nuclear Information System (INIS)

    Meyers, S.C.; Henderson, J.M.

    1980-05-01

    The W-1 Sodium Loop Safety Facility (SLSF) experiment is the fifth in a series of experiments sponsored by the Department of Energy (DOE) as part of the National Fast Breeder Reactor (FBR) Safety Assurance Program. The experiments are being conducted under the direction of Argonne National Laboratory (ANL) and Hanford Engineering Development Laboratory (HEDL). The irradiation phase of the W-1 SLSF experiment was conducted between May 27 and July 20, 1979, and terminated with incipient fuel pin cladding failure during the final boiling transient. Experimental hardware and facility performed as designed, allowing completion of all planned tests and test objectives. This paper focuses on high temperature in-fuel thermocouples and discusses their development, fabrication, and performance in the W-1 experiment

  20. Co-C and Pd-C Eutectic Fixed Points for Radiation Thermometry and Thermocouple Thermometry

    Science.gov (United States)

    Wang, L.

    2017-12-01

    Two Co-C and Pd-C eutectic fixed point cells for both radiation thermometry and thermocouple thermometry were constructed at NMC. This paper describes details of the cell design, materials used, and fabrication of the cells. The melting curves of the Co-C and Pd-C cells were measured with a reference radiation thermometer realized in both a single-zone furnace and a three-zone furnace in order to investigate furnace effect. The transition temperatures in terms of ITS-90 were determined to be 1324.18 {°}C and 1491.61 {°}C with the corresponding combined standard uncertainty of 0.44 {°}C and 0.31 {°}C for Co-C and Pd-C, respectively, taking into account of the differences of two different types of furnaces used. The determined ITS-90 temperatures are also compared with that of INRIM cells obtained using the same reference radiation thermometer and the same furnaces with the same settings during a previous bilateral comparison exercise (Battuello et al. in Int J Thermophys 35:535-546, 2014). The agreements are within k=1 uncertainty for Co-C cell and k = 2 uncertainty for Pd-C cell. Shapes of the plateaus of NMC cells and INRIM cells are compared too and furnace effects are analyzed as well. The melting curves of the Co-C and Pd-C cells realized in the single-zone furnace are also measured by a Pt/Pd thermocouple, and the preliminary results are presented as well.

  1. Experimental measurement of the interfacial heat transfer coefficients of subcooled flow boiling using micro-thermocouple and double directional images

    International Nuclear Information System (INIS)

    Seong-Jin Kim; Goon-Cherl Park

    2005-01-01

    Full text of publication follows: Models or correlations for phase interface are needed to analyze the multi-phase flow. Interfacial heat transfer coefficients are important to constitute energy equation of multi-phase flow, specially. In subcooled boiling flow, bubble condensation at the bubble-liquid interface is a major mechanism of heat transfer within bulk subcooled liquid. Bubble collapse rates and temperatures of each phase are needed to determine the interfacial heat transfer coefficient for bubble condensation. Bubble collapse rates were calculated through image processing in single direction, generally. And in case of liquid bulk temperature, which has been obtained by general temperature sensor such as thermocouple, was used. However, multi-directional images are needed to analyze images due to limitations of single directional image processing. Also, temperature sensor, which has a fast response time, must be used to obtain more accurate interfacial heat transfer coefficient. Low pressure subcooled water flow experiments using micro-thermocouple and double directional image processing with mirrors were conducted to investigate bubble condensation phenomena and to modify interfacial heat transfer correlation. Experiments were performed in a vertical subcooled boiling flow of a rectangular channel. Bubble condensing traces with respect to time were recorded by high speed camera in double direction and bubble collapse rates were calculated by processing recorded digital images. Temperatures were measured by micro-thermocouple, which is a K-type with a 12.7 μm diameter. The liquid temperature was estimated by the developed algorithm to discriminate phases and find each phase temperature in the measured temperature including both liquid and bubble temperature. The interfacial heat transfer coefficient for bubble condensation was calculated from the bubble collapse rates and the estimated liquid temperature, and its correlation was modified. The modified

  2. Investigation of pool boiling dynamics on a rectangular heater using nano-thermocouples: is it chaotic or stochastic?

    Energy Technology Data Exchange (ETDEWEB)

    Sathyamurthi, Vijaykumar; Banerjee, Debjyoti [Texas A and M University, College Station, TX (United States). Dept. of Mechanical Engineering], e-mail: dbanerjee@tamu.edu

    2009-07-01

    The non-linear dynamical model of pool boiling on a horizontal rectangular heater is assessed from experimental results in this study. Pool boiling experiments are conducted over a horizontal rectangular silicon substrate measuring 63 mm x 35 mm with PF-5060 as the test fluid. Novel nano-thermocouples, micro-machined in-situ on the silicon substrate are used to measure the surface temperature fluctuations for steady state pool boiling. The acquisition frequency for temperature data from the nano-thermocouples is 1 k Hz. The surface temperature fluctuations are analyzed using the TISEAN{sup c} package. A time-delay embedding is employed to generate higher dimensional phase-space vectors from the temperature time series record. The optimal delay is determined from the first minimum of the mutual information function. Techniques such as recurrence plots, and false nearest neighbors tests are employed to assess the presence of deterministic chaotic dynamics. Chaos quantifiers such as correlation dimensions are found for various pool boiling regimes using the raw data as well as noise-reduced data. Additionally, pseudo-phase spaces are used to reconstruct the 'attractors'. The results after non-linear noise reduction shows definitive presence of low-dimensional (d {<=} 7) chaos in fully developed nucleate boiling, at critical heat flux and in film boiling. (author)

  3. Investigation of pool boiling dynamics on a rectangular heater using nano-thermocouples: is it chaotic or stochastic?

    International Nuclear Information System (INIS)

    Sathyamurthi, Vijaykumar; Banerjee, Debjyoti

    2009-01-01

    The non-linear dynamical model of pool boiling on a horizontal rectangular heater is assessed from experimental results in this study. Pool boiling experiments are conducted over a horizontal rectangular silicon substrate measuring 63 mm x 35 mm with PF-5060 as the test fluid. Novel nano-thermocouples, micro-machined in-situ on the silicon substrate are used to measure the surface temperature fluctuations for steady state pool boiling. The acquisition frequency for temperature data from the nano-thermocouples is 1 k Hz. The surface temperature fluctuations are analyzed using the TISEAN c package. A time-delay embedding is employed to generate higher dimensional phase-space vectors from the temperature time series record. The optimal delay is determined from the first minimum of the mutual information function. Techniques such as recurrence plots, and false nearest neighbors tests are employed to assess the presence of deterministic chaotic dynamics. Chaos quantifiers such as correlation dimensions are found for various pool boiling regimes using the raw data as well as noise-reduced data. Additionally, pseudo-phase spaces are used to reconstruct the 'attractors'. The results after non-linear noise reduction shows definitive presence of low-dimensional (d ≤ 7) chaos in fully developed nucleate boiling, at critical heat flux and in film boiling. (author)

  4. Análise térmica e caracterização elétrica de materiais cerâmicos com comportamento termistor à base de óxidos de manganês, de níquel e de cobalto Thermal analysis and electrical characterization of ceramic thermistors based on manganese, nickel and cobalt oxides

    Directory of Open Access Journals (Sweden)

    J. M. Ferreira Jr.

    2007-12-01

    Full Text Available Materiais cerâmicos à base de óxidos de manganês, de níquel e de cobalto foram preparados por meio de mistura de óxidos seguida de homogeneização e sinterização a 1250 ºC. Os compostos foram caracterizados por meio das técnicas de difração de raios X e microscopia eletrônica de varredura. Análise termogravimétrica foi feita sob atmosferas oxidante e redutora. O comportamento termistor foi estudado por meio de medidas de resistividade elétrica pela técnica dc de duas pontas de prova entre temperatura ambiente e 220 °C. Os principais resultados mostram a preparação de termistores em ampla faixa de resposta elétrica por meio da variação da composição relativa dos óxidos de manganês, de níquel e de cobalto.Ceramic thermistors based on manganese, nickel and cobalt oxides were prepared by mixing these oxides followed by pressing and sintering at 1250 °C. The oxides were characterized by X-ray diffraction and scanning electron microscopy. The thermistor behavior was studied by two-probe dc electrical resistivity measurements in the room temperature-220 °C range. The main results show the possibility of preparing thermistors in a wide range of electrical response by suitable choice of the relative concentrations of the precursor oxides.

  5. Boiling detection using signals of self-powered neutron detectors and thermocouples

    International Nuclear Information System (INIS)

    Kozma, R.

    1989-01-01

    A specially-equipped simulated fuel assembly has been placed into the core of the 2 MW research reactor of the IRI, Delft. In this paper the recent results concerning the detection of coolant boiling in the simulated fuel assembly are introduced. Applying the theory of boiling temperature noise, different stages of boiling, i.e. one-phase flow, subcooled boiling, volume boiling, were identified in the measurements using the low-frequency noise components of the thermocouple signals. It has been ascertained that neutron noise spectra remained unchanged when subcooled boiling appeared, and that they changed reasonably only when developed volume boiling took place in the channels. At certain neutron detector positions neutron spectra did not vary at all, although developed volume boiling occurred at a distance of 3-4 cm from these neutron detectors. This phenomenon was applied in studying the field-of-view of neutron detectors

  6. Flow measurements using noise signals of axially displaced thermocouples

    Energy Technology Data Exchange (ETDEWEB)

    Kozma, R.; Hoogenboom, J.E. (Interuniversitair Reactor Inst., Delft (Netherlands))

    1990-01-01

    Determination of the flow rate of the coolant in the cooling channels of nuclear reactors is an important aspect of core monitoring. It is usually impossible to measure the flow by flowmeters in the individual channels due to the lack of space and safety reasons. An alternative method is based on the analysis of noise signals of the available in-core detectors. In such a noise method, a transit time which characterises the propagation of thermohydraulic fluctuations (density or temperature fluctuations) in the coolant is determined from the correlation between the noise signals of axially displaced detectors. In this paper, the results of flow measurements using axially displaced thermocouples in the channel wall will be presented. The experiments have been performed in a simulated MRT-type fuel assembly located in the research reactor HOR of the Interfaculty Reactor Institute, Delft. It was found that the velocities obtained via temperature noise correlation methods are significantly larger than the area-averaged velocity in the single-phase coolant flow. Model calculations show that the observed phenomenon can be explained by effects due to the radial velocity distribution in the channel. (author).

  7. Investigation of aquifer-estuary interaction using wavelet analysis of fiber-optic temperature data

    Science.gov (United States)

    Henderson, R.D.; Day-Lewis, Frederick D.; Harvey, Charles F.

    2009-01-01

    Fiber-optic distributed temperature sensing (FODTS) provides sub-minute temporal and meter-scale spatial resolution over kilometer-long cables. Compared to conventional thermistor or thermocouple-based technologies, which measure temperature at discrete (and commonly sparse) locations, FODTS offers nearly continuous spatial coverage, thus providing hydrologic information at spatiotemporal scales previously impossible. Large and information-rich FODTS datasets, however, pose challenges for data exploration and analysis. To date, FODTS analyses have focused on time-series variance as the means to discriminate between hydrologic phenomena. Here, we demonstrate the continuous wavelet transform (CWT) and cross-wavelet transform (XWT) to analyze FODTS in the context of related hydrologic time series. We apply the CWT and XWT to data from Waquoit Bay, Massachusetts to identify the location and timing of tidal pumping of submarine groundwater.

  8. Tile Surface Thermocouple Measurement Challenges from the Orbiter Boundary Layer Transition Flight Experiment

    Science.gov (United States)

    Campbell, Charles H.; Berger, Karen; Anderson, Brian

    2012-01-01

    Hypersonic entry flight testing motivated by efforts seeking to characterize boundary layer transition on the Space Shuttle Orbiters have identified challenges in our ability to acquire high quality quantitative surface temperature measurements versus time. Five missions near the end of the Space Shuttle Program implemented a tile surface protuberance as a boundary layer trip together with tile surface thermocouples to capture temperature measurements during entry. Similar engineering implementations of these measurements on Discovery and Endeavor demonstrated unexpected measurement voltage response during the high heating portion of the entry trajectory. An assessment has been performed to characterize possible causes of the issues experienced during STS-119, STS-128, STS-131, STS-133 and STS-134 as well as similar issues encountered during other orbiter entries.

  9. A preliminary study of oxidation-resistant coatings on refractory-metal thermocouple sheaths

    International Nuclear Information System (INIS)

    Wilkins, S.C.

    1985-01-01

    The need to make reliable temperature measurements up to 2200 0 C or higher in steam environments during in-pile nuclear fuel damage tests led to a search for oxidation-resistant coatings for the refractory-metal sheaths used to enclose and protect thermocouples used for such measurements. Iridium, thoria, and thoria-over-iridium coatings were separately sputter-deposited on molybdenum-rhenium alloy protection tubes for evaluation. The coated samples were individually heated in flowing steam in an induction furnace. An extension tube welded to each sample was connected to a vacuum pump and gauge; failure of the sample was detected by noting the degradation of the vacuum maintained in the sample. Relatively heavy coatings of iridium provided a modest degree of oxidation protection at the temperatures of interest. Thoria coatings provided no significant protection at those temperatures, compared to uncoated control samples

  10. Description of an identification method of thermocouple time constant based on application of recursive numerical filtering to temperature fluctuation

    International Nuclear Information System (INIS)

    Bernardin, B.; Le Guillou, G.; Parcy, JP.

    1981-04-01

    Usual spectral methods, based on temperature fluctuation analysis, aiming at thermocouple time constant identification are using an equipment too much sophisticated for on-line application. It is shown that numerical filtering is optimal for this application, the equipment is simpler than for spectral methods and less samples of signals are needed for the same accuracy. The method is described and a parametric study was performed using a temperature noise simulator [fr

  11. Operating Temperatures of a Sodium-Cooled Exhaust Valve as Measured by a Thermocouple

    Science.gov (United States)

    Sanders, J. C.; Wilsted, H. D.; Mulcahy, B. A.

    1943-01-01

    A thermocouple was installed in the crown of a sodium-cooled exhaust valve. The valve was then tested in an air-cooled engine cylinder and valve temperatures under various engine operating conditions were determined. A temperature of 1337 F was observed at a fuel-air ratio of 0.064, a brake mean effective pressure of 179 pounds per square inch, and an engine speed of 2000 rpm. Fuel-air ratio was found to have a large influence on valve temperature, but cooling-air pressure and variation in spark advance had little effect. An increase in engine power by change of speed or mean effective pressure increased the valve temperature. It was found that the temperature of the rear spark-plug bushing was not a satisfactory indication of the temperature of the exhaust valve.

  12. Flexibility.

    Science.gov (United States)

    Humphrey, L. Dennis

    1981-01-01

    Flexibility is an important aspect of all sports and recreational activities. Flexibility can be developed and maintained by stretching exercises. Exercises designed to develop flexibility in ankle joints, knees, hips, and the lower back are presented. (JN)

  13. Comparison of two surface temperature measurement using thermocouples and infrared camera

    Directory of Open Access Journals (Sweden)

    Michalski Dariusz

    2017-01-01

    Full Text Available This paper compares two methods applied to measure surface temperatures at an experimental setup designed to analyse flow boiling heat transfer. The temperature measurements were performed in two parallel rectangular minichannels, both 1.7 mm deep, 16 mm wide and 180 mm long. The heating element for the fluid flowing in each minichannel was a thin foil made of Haynes-230. The two measurement methods employed to determine the surface temperature of the foil were: the contact method, which involved mounting thermocouples at several points in one minichannel, and the contactless method to study the other minichannel, where the results were provided with an infrared camera. Calculations were necessary to compare the temperature results. Two sets of measurement data obtained for different values of the heat flux were analysed using the basic statistical methods, the method error and the method accuracy. The experimental error and the method accuracy were taken into account. The comparative analysis showed that although the values and distributions of the surface temperatures obtained with the two methods were similar but both methods had certain limitations.

  14. Energy deposition measurements in fast reactor safety experiments with fission thermocouple detectors

    International Nuclear Information System (INIS)

    Wright, S.A.; Scott, H.L.

    1979-01-01

    The investigation of phenomena occurring in in-pile fast reactor safety experiments requires an accurate measurement of the time dependent energy depositions within the fissile material. At Sandia Laboratories thin-film fission thermocouples are being developed for this purpose. These detectors have high temperature capabilities (400 to 500 0 C), are sodium compatible, and have milli-second time response. A significant advantage of these detectors for use as energy deposition monitors is that they produce an output voltage which is directly dependent on the temperature of a small chip of fissile material within the detectors. However, heat losses within the detector make it necessary to correct the response of the detector to determine the energy deposition. A method of correcting the detector response which uses an inverse convolution procedure has been developed and successfully tested with experimental data obtained in the Sandia Pulse Reactor (SPR-II) and in the Annular Core Research Reactor

  15. SMORN-1: thermoelectrically generated noise in sheathed thermocouples and in other low level instrumentation cables

    International Nuclear Information System (INIS)

    Mathieu, F.; Meier, R.; Soenen, M.; Delcon, M.; Nysten, C.

    Starting from the fact that thermoelectric emfs of thermocouples are generated in the thermal gradients and not at the hot junction, it is shown how thermoelectric heterogeneity in conjunction with natural and forced convection phenomena gives rise to unwanted noise called: ''thermoelectric noise'' in the technological sense. A distinction is made between four different types of noise--i.e. uncorrelated noise, correlated noise, spectral noise and thermoelectric noise in the physical sense--each of which has its own characteristics. The experimental results presented reveal that noise amplitudes may be quite embarrassing when dealing with problems of quantitative signal fluctuation analysis. It is however emphasized that thermoelectric noise may also convey useful information which, without noise, might be lost

  16. Manifestations of nonlinearity in fuel center thermocouple steady-state and transient data: implications for data analysis

    International Nuclear Information System (INIS)

    Lanning, D.D.; Barnes, B.O.; Williford, R.E.

    1979-01-01

    The interpretation and verification of fuel centerline thermocouple data are analyzed. Two new concepts are discussed along with their application to in-reactor data from IFA-432, a heavily instrumented six-rod Halden reactor test assembly sponsored by the Nuclear Regulatory Commission. The main ideas presented in this report are that: it is more useful to plot resistance versus power than simply to plot temperature versus power; and the response of the centerline temperature to a linear power decrease is correlated to the rod's current resistance-vs-power behavior. Thus, the resistance-vs-power measurement can be verified by performing a linear power decrease and by plotting the temperature response

  17. Flexible Bronchoscopy.

    Science.gov (United States)

    Miller, Russell J; Casal, Roberto F; Lazarus, Donald R; Ost, David E; Eapen, George A

    2018-03-01

    Flexible bronchoscopy has changed the course of pulmonary medicine. As technology advances, the role of the flexible bronchoscope for both diagnostic and therapeutic indications is continually expanding. This article reviews the historical development of the flexible bronchoscopy, fundamental uses of the flexible bronchoscope as a tool to examine the central airways and obtain diagnostic tissue, and the indications, complications, and contraindications to flexible bronchoscopy. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Specific features of thermocouple calorimeter application for measurements of pulsed X-ray emission from plasma

    International Nuclear Information System (INIS)

    Gavrilov, V. V.; Fasakhov, I. K.

    2012-01-01

    It is shown that the accuracy of time-integrated measurements of pulsed X-ray emission from hot plasma with calibrated thermocouple calorimeters is mainly determined by two factors. The first and the most important factor is heating of the filter by the absorbed X-rays; as a result, the calorimeter measures the thermal radiation of the filter, which causes appreciable distortion of the temporal profile and amplitude of the recorded signal. The second factor is the dependence of the effective depth of X-ray absorption in the dielectric that covers the entrance window of the calorimeter on the energy of X-ray photons, i.e., on the recorded radiation spectrum. The results of model calculations of the calorimeter signal are compared with the experimental data.

  19. Attachment of lead wires to thin film thermocouples mounted on high temperature materials using the parallel gap welding process

    Science.gov (United States)

    Holanda, Raymond; Kim, Walter S.; Pencil, Eric; Groth, Mary; Danzey, Gerald A.

    1990-01-01

    Parallel gap resistance welding was used to attach lead wires to sputtered thin film sensors. Ranges of optimum welding parameters to produce an acceptable weld were determined. The thin film sensors were Pt13Rh/Pt thermocouples; they were mounted on substrates of MCrAlY-coated superalloys, aluminum oxide, silicon carbide and silicon nitride. The entire sensor system is designed to be used on aircraft engine parts. These sensor systems, including the thin-film-to-lead-wire connectors, were tested to 1000 C.

  20. Preparation and Thermoelectric Characteristics of ITO/PtRh:PtRh Thin Film Thermocouple.

    Science.gov (United States)

    Zhao, Xiaohui; Wang, Hongmin; Zhao, Zixiang; Zhang, Wanli; Jiang, Hongchuan

    2017-12-15

    Thin film thermocouples (TFTCs) can provide more precise in situ temperature measurement for aerospace propulsion systems without disturbance of gas flow and surface temperature distribution of the hot components. ITO/PtRh:PtRh TFTC with multilayer structure was deposited on alumina ceramic substrate by magnetron sputtering. After annealing, the TFTC was statically calibrated for multiple cycles with temperature up to 1000 °C. The TFTC with excellent stability and repeatability was realized for the negligible variation of EMF in different calibration cycles. It is believed that owing to oxygen diffusion barriers by the oxidation of top PtRh layer and Schottky barriers formed at the grain boundaries of ITO, the variation of the carrier concentration of ITO film is minimized. Meanwhile, the life time of TFTC is more than 30 h in harsh environment. This makes ITO/PtRh:PtRh TFTC a promising candidate for precise surface temperature measurement of hot components of aeroengines.

  1. On flexibility

    OpenAIRE

    Weiss, Christoph R.; Briglauer, Wolfgang

    2000-01-01

    By building on theoretical work by Mills and Schumann (1985) and Ungern-Sternberg (1990) this paper provides evidence on the determinants of two dimensions of flexibility, the flexibility in adjusting aggregate output over time (tactical flexibility) as well as the ability to switch quickly between products (operational flexibility). Econometric analysis of a sample of 40.000 farms in Upper-Austria for the period 1980 to 1990 suggests that larger full-time farms operated by younger, better ed...

  2. Balance and flexibility.

    Science.gov (United States)

    2003-12-01

    The 'work-life balance' and flexible working are currently key buzz terms in the NHS. Those looking for more information on these topics should visit Flexibility at www.flexibility.co.uk for a host of resources designed to support new ways of working, including information on flexible workers and flexible rostering, the legal balancing act for work-life balance and home working.

  3. Home-made temperature monitoring system from four-channel K-type thermocouples via internet of thing technology platform

    Science.gov (United States)

    Detmod, Thitaporn; Özmen, Yiǧiter; Songkaitiwong, Kittiphot; Saenyot, Khanuengchat; Locharoenrat, Kitsakorn; Lekchaum, Sarai

    2018-06-01

    This paper is aimed to design and construct the home-made temperature monitoring system from four-channel K-type thermocouples in order to improve the temperature measurement based on standard evaluation measurements guidance. The temperature monitoring system was capable to record the temperature on SD card and to display the realtime temperature on Internet of Thing Technology platform. The temperature monitoring system was tested in terms of the temperature measurement accuracy and delay response time. It was found that a standard deviation was acceptable as compared to the Instrument Society of America. The response time of the microcontroller to SD card was 2 sec faster than that of the microcontroller to Thingspeak.

  4. Boiling point measurement of a small amount of brake fluid by thermocouple and its application.

    Science.gov (United States)

    Mogami, Kazunari

    2002-09-01

    This study describes a new method for measuring the boiling point of a small amount of brake fluid using a thermocouple and a pear shaped flask. The boiling point of brake fluid was directly measured with an accuracy that was within approximately 3 C of that determined by the Japanese Industrial Standards method, even though the sample volume was only a few milliliters. The method was applied to measure the boiling points of brake fluid samples from automobiles. It was clear that the boiling points of brake fluid from some automobiles dropped to approximately 140 C from about 230 C, and that one of the samples from the wheel cylinder was approximately 45 C lower than brake fluid from the reserve tank. It is essential to take samples from the wheel cylinder, as this is most easily subjected to heating.

  5. Scanning thermal microscopy based on a quartz tuning fork and a micro-thermocouple in active mode (2ω method)

    International Nuclear Information System (INIS)

    Bontempi, Alexia; Nguyen, Tran Phong; Salut, Roland; Thiery, Laurent; Teyssieux, Damien; Vairac, Pascal

    2016-01-01

    A novel probe for scanning thermal microscope using a micro-thermocouple probe placed on a Quartz Tuning Fork (QTF) is presented. Instead of using an external deflection with a cantilever beam for contact detection, an original combination of piezoelectric resonator and thermal probe is employed. Due to a non-contact photothermal excitation principle, the high quality factor of the QTF allows the probe-to-surface contact detection. Topographic and thermal scanning images obtained on a specific sample points out the interest of our system as an alternative to cantilevered resistive probe systems which are the most spread.

  6. Scanning thermal microscopy based on a quartz tuning fork and a micro-thermocouple in active mode (2ω method).

    Science.gov (United States)

    Bontempi, Alexia; Nguyen, Tran Phong; Salut, Roland; Thiery, Laurent; Teyssieux, Damien; Vairac, Pascal

    2016-06-01

    A novel probe for scanning thermal microscope using a micro-thermocouple probe placed on a Quartz Tuning Fork (QTF) is presented. Instead of using an external deflection with a cantilever beam for contact detection, an original combination of piezoelectric resonator and thermal probe is employed. Due to a non-contact photothermal excitation principle, the high quality factor of the QTF allows the probe-to-surface contact detection. Topographic and thermal scanning images obtained on a specific sample points out the interest of our system as an alternative to cantilevered resistive probe systems which are the most spread.

  7. Scanning thermal microscopy based on a quartz tuning fork and a micro-thermocouple in active mode (2ω method)

    Energy Technology Data Exchange (ETDEWEB)

    Bontempi, Alexia; Nguyen, Tran Phong; Salut, Roland; Thiery, Laurent; Teyssieux, Damien; Vairac, Pascal [FEMTO-ST Institute UMR 6174, Université de Franche-Comté, CNRS, ENSMM, UTBM, 15B Avenue des Montboucons, F-25030 Besançon (France)

    2016-06-15

    A novel probe for scanning thermal microscope using a micro-thermocouple probe placed on a Quartz Tuning Fork (QTF) is presented. Instead of using an external deflection with a cantilever beam for contact detection, an original combination of piezoelectric resonator and thermal probe is employed. Due to a non-contact photothermal excitation principle, the high quality factor of the QTF allows the probe-to-surface contact detection. Topographic and thermal scanning images obtained on a specific sample points out the interest of our system as an alternative to cantilevered resistive probe systems which are the most spread.

  8. Office flexible cystoscopy.

    Science.gov (United States)

    Kavoussi, L R; Clayman, R V

    1988-11-01

    Since the development of the first purpose-built flexible cystoscope in 1984, flexible cystoscopy has become an accepted diagnostic and therapeutic modality. Indeed, it is estimated that more than 10 per cent of practicing urologists are already familiar with this technology. The flexible cystoscope has markedly extended the urologist's ability to examine the bladder, and it has become a valuable adjunct to the rigid cystoscope. Although the operation of this instrument is vastly different from that of its rigid counterpart, with practice, the technique can be learned. After experience is obtained with diagnostic flexible cystoscopy, the urologist will likely prefer this new instrument for bladder inspection, as it provides for a more thorough yet less morbid and less expensive examination. In the future, the development of improved and smaller instrumentation will further extend the therapeutic indications for flexible cystoscopy. Indeed, advances in laser technology are already providing the urologist with 300- to 600-micron (0.9 to 1.8F) flexible probes capable of incision (KTP laser), fulguration (Nd:YAG laser), and stone disintegration (tunable dye laser). Lastly, the skills obtained in using the flexible cystoscope are all readily applicable to the development of dexterity with the already available flexible nephroscope and the more recently developed flexible ureteroscope.

  9. On the usability of `compensated temperature` output of Honeywell PPTR sensor for coastal oceanographic and limnological studies

    Digital Repository Service at National Institute of Oceanography (India)

    Mehra, P.; Joseph, A.; Desai, R.G.P.; Vijaykumar, K.; Sundar, D.; Tengali, S.

    and those of Aanderraa current meter's Fenwall GB 32JM19 thermistor probe and NIO water level recorder's YSI thermistor probes were encouraging. However, while the Fenwall GB 32JM19 thermistor probe and the YSI thermistor probes detects changes...

  10. n+ GaAs/AuGeNi-Au Thermocouple-Type RF MEMS Power Sensors Based on Dual Thermal Flow Paths in GaAs MMIC

    Directory of Open Access Journals (Sweden)

    Zhiqiang Zhang

    2017-06-01

    Full Text Available To achieve radio frequency (RF power detection, gain control, and circuit protection, this paper presents n+ GaAs/AuGeNi-Au thermocouple-type RF microelectromechanical system (MEMS power sensors based on dual thermal flow paths. The sensors utilize a conversion principle of RF power-heat-voltage, where a thermovoltage is obtained as the RF power changes. To improve the heat transfer efficiency and the sensitivity, structures of two heat conduction paths are designed: one in which a thermal slug of Au is placed between two load resistors and hot junctions of the thermocouples, and one in which a back cavity is fabricated by the MEMS technology to form a substrate membrane underneath the resistors and the hot junctions. The improved sensors were fabricated by a GaAs monolithic microwave integrated circuit (MMIC process. Experiments show that these sensors have reflection losses of less than −17 dB up to 12 GHz. At 1, 5, and 10 GHz, measured sensitivities are about 63.45, 53.97, and 44.14 µV/mW for the sensor with the thermal slug, and about 111.03, 94.79, and 79.04 µV/mW for the sensor with the thermal slug and the back cavity, respectively.

  11. Flexible structured high-frequency film bulk acoustic resonator for flexible wireless electronics

    International Nuclear Information System (INIS)

    Zhou, Changjian; Shu, Yi; Yang, Yi; Ren, Tian-Ling; Jin, Hao; Dong, Shu-Rong; Chan, Mansun

    2015-01-01

    Flexible electronics have inspired many novel and very important applications in recent years and various flexible electronic devices such as diodes, transistors, circuits, sensors, and radiofrequency (RF) passive devices including antennas and inductors have been reported. However, the lack of a high-performance RF resonator is one of the key bottlenecks to implement flexible wireless electronics. In this study, for the first time, a novel ultra-flexible structured film bulk acoustic resonator (FBAR) is proposed. The flexible FBAR is fabricated on a flexible polyimide substrate using piezoelectric thin film aluminum nitride (AlN) for acoustic wave excitation. Both the shear wave and longitudinal wave can be excited under the surface interdigital electrodes configuration we proposed. In the case of the thickness extension mode, a flexible resonator with a working frequency as high as of 5.2325 GHz has been realized. The resonators stay fully functional under bending status and after repeated bending and re-flattening operations. This flexible high-frequency resonator will serve as a key building block for the future flexible wireless electronics, greatly expanding the application scope of flexible electronics. (paper)

  12. Advances in Current Rating Techniques for Flexible Printed Circuits

    Science.gov (United States)

    Hayes, Ron

    2014-01-01

    Twist Capsule Assemblies are power transfer devices commonly used in spacecraft mechanisms that require electrical signals to be passed across a rotating interface. Flexible printed circuits (flex tapes, see Figure 2) are used to carry the electrical signals in these devices. Determining the current rating for a given trace (conductor) size can be challenging. Because of the thermal conditions present in this environment the most appropriate approach is to assume that the only means by which heat is removed from the trace is thru the conductor itself, so that when the flex tape is long the temperature rise in the trace can be extreme. While this technique represents a worst-case thermal situation that yields conservative current ratings, this conservatism may lead to overly cautious designs when not all traces are used at their full rated capacity. A better understanding of how individual traces behave when they are not all in use is the goal of this research. In the testing done in support of this paper, a representative flex tape used for a flight Solar Array Drive Assembly (SADA) application was tested by energizing individual traces (conductors in the tape) in a vacuum chamber and the temperatures of the tape measured using both fine-gauge thermocouples and infrared thermographic imaging. We find that traditional derating schemes used for bundles of wires do not apply for the configuration tested. We also determine that single active traces located in the center of a flex tape operate at lower temperatures than those on the outside edges.

  13. Flexibility@Work 2013: yearly report on flexible labor and employment

    NARCIS (Netherlands)

    Berkhout, E.; Heyma, A.; Prins, J.

    2013-01-01

    There is no clear evidence that the strong growth in the share of flexible labor relations between 2002 and 2007 points at a worldwide trend towards a larger share of flexible labor at the expense of traditional open-ended labor contracts. The growth in flexible labor varies too much between

  14. Study of Thermocurrents in ILC cavities via measurements of the Seebeck Effect in niobium, titanium, and stainless steel thermocouples

    Energy Technology Data Exchange (ETDEWEB)

    Cooley, Victoria [Univ. of Wisconsin, Madison, WI (United States)

    2014-01-01

    The goals of Fermilab’s Superconductivity and Radio Frequency Development Department are to engineer, fabricate, and improve superconducting radio frequency (SCRF) cavities in the interest of advancing accelerator technology. Improvement includes exploring possible limitations on cavity performance and mitigating such impediments. This report focuses on investigating and measuring the Seebeck Effect observed in cavity constituents titanium, niobium, and stainless steel arranged in thermocouples. These junctions exist between cavities, helium jackets, and bellows, and their connection can produce a loop of electrical current and magnetic flux spontaneously during cooling. The experimental procedure and results are described and analyzed. Implications relating the results to cavity performance are discussed.

  15. n⁺ GaAs/AuGeNi-Au Thermocouple-Type RF MEMS Power Sensors Based on Dual Thermal Flow Paths in GaAs MMIC.

    Science.gov (United States)

    Zhang, Zhiqiang; Liao, Xiaoping

    2017-06-17

    To achieve radio frequency (RF) power detection, gain control, and circuit protection, this paper presents n⁺ GaAs/AuGeNi-Au thermocouple-type RF microelectromechanical system (MEMS) power sensors based on dual thermal flow paths. The sensors utilize a conversion principle of RF power-heat-voltage, where a thermovoltage is obtained as the RF power changes. To improve the heat transfer efficiency and the sensitivity, structures of two heat conduction paths are designed: one in which a thermal slug of Au is placed between two load resistors and hot junctions of the thermocouples, and one in which a back cavity is fabricated by the MEMS technology to form a substrate membrane underneath the resistors and the hot junctions. The improved sensors were fabricated by a GaAs monolithic microwave integrated circuit (MMIC) process. Experiments show that these sensors have reflection losses of less than -17 dB up to 12 GHz. At 1, 5, and 10 GHz, measured sensitivities are about 63.45, 53.97, and 44.14 µ V/mW for the sensor with the thermal slug, and about 111.03, 94.79, and 79.04 µ V/mW for the sensor with the thermal slug and the back cavity, respectively.

  16. Thermocouple and infrared sensor-based measurement of temperature distribution in metal cutting.

    Science.gov (United States)

    Kus, Abdil; Isik, Yahya; Cakir, M Cemal; Coşkun, Salih; Özdemir, Kadir

    2015-01-12

    In metal cutting, the magnitude of the temperature at the tool-chip interface is a function of the cutting parameters. This temperature directly affects production; therefore, increased research on the role of cutting temperatures can lead to improved machining operations. In this study, tool temperature was estimated by simultaneous temperature measurement employing both a K-type thermocouple and an infrared radiation (IR) pyrometer to measure the tool-chip interface temperature. Due to the complexity of the machining processes, the integration of different measuring techniques was necessary in order to obtain consistent temperature data. The thermal analysis results were compared via the ANSYS finite element method. Experiments were carried out in dry machining using workpiece material of AISI 4140 alloy steel that was heat treated by an induction process to a hardness of 50 HRC. A PVD TiAlN-TiN-coated WNVG 080404-IC907 carbide insert was used during the turning process. The results showed that with increasing cutting speed, feed rate and depth of cut, the tool temperature increased; the cutting speed was found to be the most effective parameter in assessing the temperature rise. The heat distribution of the cutting tool, tool-chip interface and workpiece provided effective and useful data for the optimization of selected cutting parameters during orthogonal machining.

  17. Dynamic Model of a Rotating Flexible Arm-Flexible Root Mechanism Driven by a Shaft Flexible in Torsion

    Directory of Open Access Journals (Sweden)

    S.Z. Ismail

    2006-01-01

    Full Text Available This paper presents a dynamic model of a rotating flexible beam carrying a payload at its tip. The model accounts for the driving shaft and the arm root flexibilities. The finite element method and the Lagrangian dynamics are used in deriving the equations of motion with the small deformation theory assumptions and the Euler-Bernoulli beam theory. The obtained model is a nonlinear-coupled system of differential equations. The model is simulated for different combinations of shaft and root flexibilities and arm properties. The simulation results showed that the root flexibility is an important factor that should be considered in association with the arm and shaft flexibilities, as its dynamics influence the motor motion. Moreover, the effect of system non-linearity on the dynamic behavior is investigated by simulating the equivalent linearized system and it was found to be an important factor that should be considered, particularly when designing a control strategy for practical implementation.

  18. Thermal cycling properties of a lead-free positive temperature coefficient thermistor in the Ba0.97(Bi0.5Na0.5)0.03TiO3 system

    Science.gov (United States)

    Choi, Hyoung-Seuk; Choi, Soon-Mok; Choi, Duck-Kyun

    2016-01-01

    A Pb-free PTC (positive temperature coefficient thermistor) heater was developed in the Ba0.97(Bi0.5Na0.5)0.03TiO3 system especially for automotive part applications. The reliability was verified by using a thermal cycling test designed on the basis of the result from a quality function deployment (QFD) analysis. We compared the thermal cycling test results from the newly-developed Pb-free PTC heaters with the results from PTC heaters currently on the market, namely, PTC heaters containing Pb. Life prediction and stress-strength relationships were analyzed together with a thermal diffusivity evaluation. We discuss the potential failure mechanisms during the thermal cycling test, focusing on the fact that electrical degradation in PTC materials is closely related to mechanical degradation due to the internal stress in the materials that comes from repeated phase changes. Different grain size distributions on the sintered bulks were considered to a key factor for explaining the different results of the reliability tests between the new Pb-free PTC heaters developed in this study and the commercial PTC heaters containing Pb.

  19. Global Sourcing Flexibility

    DEFF Research Database (Denmark)

    Ørberg Jensen, Peter D.; Petersen, Bent

    2013-01-01

    the higher costs (but decreased risk for value chain disruption) embedded in a more flexible global sourcing model that allows the firm to replicate and/or relocate activities across multiple locations. We develop a model and propositions on facilitating and constraining conditions of global sourcing...... sourcing flexibility. Here we draw on prior research in the fields of organizational flexibility, international business and global sourcing as well as case examples and secondary studies. In the second part of the paper, we discuss the implications of global sourcing flexibility for firm strategy...... and operations against the backdrop of the theory-based definition of the construct. We discuss in particular the importance of global sourcing flexibility for operational performance stability, and the trade-off between specialization benefits, emerging from location and service provider specialization, versus...

  20. Conflicting flexibility

    NARCIS (Netherlands)

    De Jong, P.; Schaap, A.

    2011-01-01

    New buildings are designed for first users. For a sustainable approach there are many advantages in designing in flexibility and adjustability in order to enable and facilitate the other sequential users. For the first investor this flexibility is translated into improved exit values due to

  1. Inter-vertebral flexibility of the ostrich neck: implications for estimating sauropod neck flexibility.

    Science.gov (United States)

    Cobley, Matthew J; Rayfield, Emily J; Barrett, Paul M

    2013-01-01

    The flexibility and posture of the neck in sauropod dinosaurs has long been contentious. Improved constraints on sauropod neck function will have major implications for what we know of their foraging strategies, ecology and overall biology. Several hypotheses have been proposed, based primarily on osteological data, suggesting different degrees of neck flexibility. This study attempts to assess the effects of reconstructed soft tissues on sauropod neck flexibility through systematic removal of muscle groups and measures of flexibility of the neck in a living analogue, the ostrich (Struthio camelus). The possible effect of cartilage on flexibility is also examined, as this was previously overlooked in osteological estimates of sauropod neck function. These comparisons show that soft tissues are likely to have limited the flexibility of the neck beyond the limits suggested by osteology alone. In addition, the inferred presence of cartilage, and varying the inter-vertebral spacing within the synovial capsule, also affect neck flexibility. One hypothesis proposed that flexibility is constrained by requiring a minimum overlap between successive zygapophyses equivalent to 50% of zygapophyseal articular surface length (ONP50). This assumption is tested by comparing the maximum flexibility of the articulated cervical column in ONP50 and the flexibility of the complete neck with all tissues intact. It is found that this model does not adequately convey the pattern of flexibility in the ostrich neck, suggesting that the ONP50 model may not be useful in determining neck function if considered in isolation from myological and other soft tissue data.

  2. Inter-vertebral flexibility of the ostrich neck: implications for estimating sauropod neck flexibility.

    Directory of Open Access Journals (Sweden)

    Matthew J Cobley

    Full Text Available The flexibility and posture of the neck in sauropod dinosaurs has long been contentious. Improved constraints on sauropod neck function will have major implications for what we know of their foraging strategies, ecology and overall biology. Several hypotheses have been proposed, based primarily on osteological data, suggesting different degrees of neck flexibility. This study attempts to assess the effects of reconstructed soft tissues on sauropod neck flexibility through systematic removal of muscle groups and measures of flexibility of the neck in a living analogue, the ostrich (Struthio camelus. The possible effect of cartilage on flexibility is also examined, as this was previously overlooked in osteological estimates of sauropod neck function. These comparisons show that soft tissues are likely to have limited the flexibility of the neck beyond the limits suggested by osteology alone. In addition, the inferred presence of cartilage, and varying the inter-vertebral spacing within the synovial capsule, also affect neck flexibility. One hypothesis proposed that flexibility is constrained by requiring a minimum overlap between successive zygapophyses equivalent to 50% of zygapophyseal articular surface length (ONP50. This assumption is tested by comparing the maximum flexibility of the articulated cervical column in ONP50 and the flexibility of the complete neck with all tissues intact. It is found that this model does not adequately convey the pattern of flexibility in the ostrich neck, suggesting that the ONP50 model may not be useful in determining neck function if considered in isolation from myological and other soft tissue data.

  3. Accounting for the inertia of the thermocouples' measurements by modelling of a NPP Kalinin-3 transient with the coupled system code ATHLET-BIPR-VVER

    International Nuclear Information System (INIS)

    Nikonov, S.; Velkov, K.

    2008-01-01

    The ATHLET-BIPR-VVER coupled system code is applied for performing of safety analysis for different WWER reactors. During the last years its validation matrix is continuously being enlarged. The measurements performed during the commissioning phase of NPP Kalinin Unit 3 for the transient 'Switching-off of one Main Circulation Pump at nominal power' are very well documented and have a variety of recorded integral and local thermo-hydraulic and neutron-physic parameters including the measurements' errors. This data is being used for further validation of the coupled code system ATHLET-BIPR-VVER. In the paper are discussed the problems and our solutions by the correct interpretation of the measured thermocouples' records at NPP Kalinin-3 and the comparison with the predicted results by the coupled thermal-hydraulic/neutron-kinetic code ATHLET-BIPR-VVER. Of primary importance by such comparisons is the correct accounting of the fluid mixing process that take place in the surrounding of the measuring sensors and also the consideration of the time delay (inertia term) of the measuring devices. On the bases of previous experience and many simulations of the defined transient a method is discussed and proposed to consider correctly the inertia term of the thermocouples' measurements. The new modelling is implemented in the coupled system code ATHLET-BIPR-VVER for further validation. (Author)

  4. Flexible Carbon Aerogels

    Directory of Open Access Journals (Sweden)

    Marina Schwan

    2016-09-01

    Full Text Available Carbon aerogels are highly porous materials with a large inner surface area. Due to their high electrical conductivity they are excellent electrode materials in supercapacitors. Their brittleness, however, imposes certain limitations in terms of applicability. In that context, novel carbon aerogels with varying degree of flexibility have been developed. These highly porous, light aerogels are characterized by a high surface area and possess pore structures in the micrometer range, allowing for a reversible deformation of the aerogel network. A high ratio of pore size to particle size was found to be crucial for high flexibility. For dynamic microstructural analysis, compression tests were performed in-situ within a scanning electron microscope allowing us to directly visualize the microstructural flexibility of an aerogel. The flexible carbon aerogels were found to withstand between 15% and 30% of uniaxial compression in a reversible fashion. These findings might stimulate further research and new application fields directed towards flexible supercapacitors and batteries.

  5. Thermocouple and Infrared Sensor-Based Measurement of Temperature Distribution in Metal Cutting

    Directory of Open Access Journals (Sweden)

    Abdil Kus

    2015-01-01

    Full Text Available In metal cutting, the magnitude of the temperature at the tool-chip interface is a function of the cutting parameters. This temperature directly affects production; therefore, increased research on the role of cutting temperatures can lead to improved machining operations. In this study, tool temperature was estimated by simultaneous temperature measurement employing both a K-type thermocouple and an infrared radiation (IR pyrometer to measure the tool-chip interface temperature. Due to the complexity of the machining processes, the integration of different measuring techniques was necessary in order to obtain consistent temperature data. The thermal analysis results were compared via the ANSYS finite element method. Experiments were carried out in dry machining using workpiece material of AISI 4140 alloy steel that was heat treated by an induction process to a hardness of 50 HRC. A PVD TiAlN-TiN-coated WNVG 080404-IC907 carbide insert was used during the turning process. The results showed that with increasing cutting speed, feed rate and depth of cut, the tool temperature increased; the cutting speed was found to be the most effective parameter in assessing the temperature rise. The heat distribution of the cutting tool, tool-chip interface and workpiece provided effective and useful data for the optimization of selected cutting parameters during orthogonal machining.

  6. Thermocouple and Infrared Sensor-Based Measurement of Temperature Distribution in Metal Cutting

    Science.gov (United States)

    Kus, Abdil; Isik, Yahya; Cakir, M. Cemal; Coşkun, Salih; Özdemir, Kadir

    2015-01-01

    In metal cutting, the magnitude of the temperature at the tool-chip interface is a function of the cutting parameters. This temperature directly affects production; therefore, increased research on the role of cutting temperatures can lead to improved machining operations. In this study, tool temperature was estimated by simultaneous temperature measurement employing both a K-type thermocouple and an infrared radiation (IR) pyrometer to measure the tool-chip interface temperature. Due to the complexity of the machining processes, the integration of different measuring techniques was necessary in order to obtain consistent temperature data. The thermal analysis results were compared via the ANSYS finite element method. Experiments were carried out in dry machining using workpiece material of AISI 4140 alloy steel that was heat treated by an induction process to a hardness of 50 HRC. A PVD TiAlN-TiN-coated WNVG 080404-IC907 carbide insert was used during the turning process. The results showed that with increasing cutting speed, feed rate and depth of cut, the tool temperature increased; the cutting speed was found to be the most effective parameter in assessing the temperature rise. The heat distribution of the cutting tool, tool-chip interface and workpiece provided effective and useful data for the optimization of selected cutting parameters during orthogonal machining. PMID:25587976

  7. Reversibly Bistable Flexible Electronics

    KAUST Repository

    Alfaraj, Nasir

    2015-05-01

    Introducing the notion of transformational silicon electronics has paved the way for integrating various applications with silicon-based, modern, high-performance electronic circuits that are mechanically flexible and optically semitransparent. While maintaining large-scale production and prototyping rapidity, this flexible and translucent scheme demonstrates the potential to transform conventionally stiff electronic devices into thin and foldable ones without compromising long-term performance and reliability. In this work, we report on the fabrication and characterization of reversibly bistable flexible electronic switches that utilize flexible n-channel metal-oxide-semiconductor field-effect transistors. The transistors are fabricated initially on rigid (100) silicon substrates before they are peeled off. They can be used to control flexible batches of light-emitting diodes, demonstrating both the relative ease of scaling at minimum cost and maximum reliability and the feasibility of integration. The peeled-off silicon fabric is about 25 µm thick. The fabricated devices are transferred to a reversibly bistable flexible platform through which, for example, a flexible smartphone can be wrapped around a user’s wrist and can also be set back to its original mechanical position. Buckling and cyclic bending of such host platforms brings a completely new dimension to the development of flexible electronics, especially rollable displays.

  8. Flexible MEMS: A novel technology to fabricate flexible sensors and electronics

    Science.gov (United States)

    Tu, Hongen

    This dissertation presents the design and fabrication techniques used to fabricate flexible MEMS (Micro Electro Mechanical Systems) devices. MEMS devices and CMOS(Complementary Metal-Oxide-Semiconductor) circuits are traditionally fabricated on rigid substrates with inorganic semiconductor materials such as Silicon. However, it is highly desirable that functional elements like sensors, actuators or micro fluidic components to be fabricated on flexible substrates for a wide variety of applications. Due to the fact that flexible substrate is temperature sensitive, typically only low temperature materials, such as polymers, metals, and organic semiconductor materials, can be directly fabricated on flexible substrates. A novel technology based on XeF2(xenon difluoride) isotropic silicon etching and parylene conformal coating, which is able to monolithically incorporate high temperature materials and fluidic channels, was developed at Wayne State University. The technology was first implemented in the development of out-of-plane parylene microneedle arrays that can be individually addressed by integrated flexible micro-channels. These devices enable the delivery of chemicals with controlled temporal and spatial patterns and allow us to study neurotransmitter-based retinal prosthesis. The technology was further explored by adopting the conventional SOI-CMOS processes. High performance and high density CMOS circuits can be first fabricated on SOI wafers, and then be integrated into flexible substrates. Flexible p-channel MOSFETs (Metal-Oxide-Semiconductor Field-Effect-Transistors) were successfully integrated and tested. Integration of pressure sensors and flow sensors based on single crystal silicon has also been demonstrated. A novel smart yarn technology that enables the invisible integration of sensors and electronics into fabrics has been developed. The most significant advantage of this technology is its post-MEMS and post-CMOS compatibility. Various high

  9. Flexible Carpooling: Exploratory Study

    OpenAIRE

    Dorinson, Diana; Gay, Deanna; Minett, Paul; Shaheen, Susan

    2009-01-01

    Energy consumption could be reduced if more people shared rides rather than driving alone yet carpooling represents a small proportion of all potential carpoolers. Prior research has found that many who might carpool were concerned about reduced flexibility with carpooling. If flexibility is one of the barriers how could carpooling be organized to be more flexible? In Northern Virginia a flexible system has evolved where there are 3,500 single-use carpools per day. In another example there ...

  10. Local Flexibility Market Design for Aggregators Providing Multiple Flexibility Services at Distribution Network Level

    Directory of Open Access Journals (Sweden)

    Pol Olivella-Rosell

    2018-04-01

    Full Text Available This paper presents a general description of local flexibility markets as a market-based management mechanism for aggregators. The high penetration of distributed energy resources introduces new flexibility services like prosumer or community self-balancing, congestion management and time-of-use optimization. This work is focused on the flexibility framework to enable multiple participants to compete for selling or buying flexibility. In this framework, the aggregator acts as a local market operator and supervises flexibility transactions of the local energy community. Local market participation is voluntary. Potential flexibility stakeholders are the distribution system operator, the balance responsible party and end-users themselves. Flexibility is sold by means of loads, generators, storage units and electric vehicles. Finally, this paper presents needed interactions between all local market stakeholders, the corresponding inputs and outputs of local market operation algorithms from participants and a case study to highlight the application of the local flexibility market in three scenarios. The local market framework could postpone grid upgrades, reduce energy costs and increase distribution grids’ hosting capacity.

  11. [Inspecting the cochlear scala tympanic with flexible and semi-flexible micro-endoscope].

    Science.gov (United States)

    Zhang, Daoxcing; Zhang, Yankun

    2006-02-01

    Flexible and semi-flexible micro-endoscopes were used in cochlear scala tympani inspection , to explore their application in inner ear examination. Fifteen profound hearing loss patients preparing for cochlear implant were included in this study. During the operation, micro-endoscopy was performed after opening the cochlear scala tympani. And 1 mm diameter semi-flexible micro-endoscope could go as deep as 9 mm into the cochlear scala tympani, while 0. 5 mm diameter flexible micro-endoscope could go as deep as 25 mm. The inspecting results were compared with video recording. Using 0.5 mm flexible micro-endoscope, we canould check cochlear scala tympani with depth range of 15-25 mm, but the video imaging was not clear enough to examine the microstructure in the cochlear. With 1 mm diameter semi-flexible micro-endoscope, we could reach 9 mm deep into the cochlear. During the examination, we found 3 cases with calcification deposit in osseous spiral lamina, l case with granulation tissue in the lateral wall of scala tympani, no abnormal findings in the other 11 cases. Inspecting the cochlear scala tympani with 0.5 mm flexible micro-endoscope, even though we can reach the second circuit of the cochlear, it is difficult to find the pathology in the cochlear because of the poor video imaging. With 1 mm semi-flexible micro-endoscope, we can identify the microstructure of the cochlear clearly and find the pathologic changes, but the inserting depth was limited to 9 mm with limitation to examine the whole cochlear.

  12. Development of Flexible Pneumatic Cylinder with Built-in Flexible Linear Encoder and Flexible Bending Sensor

    Science.gov (United States)

    Akagi, Tetsuya; Dohta, Shujiro; Matsushita, Hisashi; Fukuhara, Akimasa

    The purpose of this study is to develop a lightweight and intelligent soft actuator which can be safely attached to the human body. A novel flexible pneumatic cylinder that can be used even if it is deformed by external force had been proposed. The cylinder can realize both pushing and pulling motions even if the cylinder bends. In this paper, a flexible pneumatic cylinder with a built-in flexible linear encoder is proposed and tested. The encoder can detect the cylinder displacement even if the cylinder bends. In the next step, to realize an intelligent flexible cylinder, it is essential to recognize the angle of deflection of the cylinder to estimate the direction of the external force. Therefore, a flexible bending sensor that can measure the directional angle by attaching it to the end of the cylinder is also proposed and tested. The tested bending sensor also consists of four inexpensive photo-reflectors set on the circumferential surface to the cylinder tube every 90 degrees from the center of the tube. By measuring the distance between the photo reflector and the surface of the tube at each point, the bending directional angle of the cylinder can be obtained. A low cost measuring system using a micro-computer incorporating a programmed Up/Down counter to measure the displacement of the cylinder is also developed. As a result, it was confirmed that the measuring accuracy of the bending directional angle was good, less than 0.7 degrees as a standard deviation.

  13. Energy Flexibility in Retail Buildings

    DEFF Research Database (Denmark)

    Ma, Zheng; Billanes, Joy Dalmacio; Kjærgaard, Mikkel Baun

    2017-01-01

    Retail buildings has an important role for demand side energy flexibility because of their high energy consumption, variety of energy flexibility resources, and centralized control via building control systems. Energy flexibility requires agreements and collaborations among different actors......), with the discussion of the stakeholders’ roles and their interrelation in delivering energy flexibility with the influential factors to the actual implementation of energy flexible operation of their buildings. Based on a literature analysis, the results cover stakeholders’ types and roles, perceptions (drivers......, barriers, and benefits), energy management activities and technology adoptions, and the stakeholders’ interaction for the energy flexibility in retail buildings....

  14. Flexible Word Classes

    DEFF Research Database (Denmark)

    • First major publication on the phenomenon • Offers cross-linguistic, descriptive, and diverse theoretical approaches • Includes analysis of data from different language families and from lesser studied languages This book is the first major cross-linguistic study of 'flexible words', i.e. words...... that cannot be classified in terms of the traditional lexical categories Verb, Noun, Adjective or Adverb. Flexible words can - without special morphosyntactic marking - serve in functions for which other languages must employ members of two or more of the four traditional, 'specialised' word classes. Thus......, flexible words are underspecified for communicative functions like 'predicating' (verbal function), 'referring' (nominal function) or 'modifying' (a function typically associated with adjectives and e.g. manner adverbs). Even though linguists have been aware of flexible world classes for more than...

  15. Attachment of Free Filament Thermocouples for Temperature Measurements on CMC

    Science.gov (United States)

    Lei, Jih-Fen; Cuy, Michael D.; Wnuk, Stephen P.

    1997-01-01

    Ceramic Matrix Composites (CMC) are being developed for use as enabling materials for advanced aeropropulsion engine and high speed civil transport applications. The characterization and testing of these advanced materials in hostile, high-temperature environments require accurate measurement of the material temperatures. Commonly used wire Thermo-Couples (TC) can not be attached to this ceramic based material via conventional spot-welding techniques. Attachment of wire TC's with commercially available ceramic cements fail to provide sufficient adhesion at high temperatures. While advanced thin film TC technology provides minimally intrusive surface temperature measurement and has good adhesion on the CMC, its fabrication requires sophisticated and expensive facilities and is very time consuming. In addition, the durability of lead wire attachments to both thin film TC's and the substrate materials requires further improvement. This paper presents a newly developed attachment technique for installation of free filament wire TC's with a unique convoluted design on ceramic based materials such as CMC's. Three CMC's (SiC/SiC CMC and alumina/alumina CMC) instrumented with type IC, R or S wire TC's were tested in a Mach 0.3 burner rig. The CMC temperatures measured from these wire TC's were compared to that from the facility pyrometer and thin film TC's. There was no sign of TC delamination even after several hours exposure to 1200 C. The test results proved that this new technique can successfully attach wire TC's on CMC's and provide temperature data in hostile environments. The sensor fabrication process is less expensive and requires very little time compared to that of the thin film TC's. The same installation technique/process can also be applied to attach lead wires for thin film sensor systems.

  16. Flexible magnetoimpedance sensor

    KAUST Repository

    Li, Bodong; Kavaldzhiev, Mincho; Kosel, Jü rgen

    2015-01-01

    Flexible magnetoimpedance (MI) sensors fabricated using a NiFe/Cu/NiFe tri-layer on Kapton substrate have been studied. A customized flexible microstrip transmission line was employed to investigate the MI sensors's magnetic field and frequency

  17. Flexible magnetoimpedance sensor

    International Nuclear Information System (INIS)

    Li, Bodong; Kavaldzhiev, Mincho N.; Kosel, Jürgen

    2015-01-01

    Flexible magnetoimpedance (MI) sensors fabricated using a NiFe/Cu/NiFe tri-layer on Kapton substrate have been studied. A customized flexible microstrip transmission line was employed to investigate the MI sensors's magnetic field and frequency responses and their dependence on the sensors's deflection. For the first time, the impedance characteristic is obtained through reflection coefficient analysis over a wide range of frequencies from 0.1 MHz to 3 GHz and for deflections ranging from zero curvature to a radius of 7.2 cm. The sensor element maintains a high MI ratio of up to 90% and magnetic sensitivity of up to 9.2%/Oe over different bending curvatures. The relationship between the curvature and material composition is discussed based on the magnetostriction effect and stress simulations. The sensor's large frequency range, simple fabrication process and high sensitivity provide a great potential for flexible electronics and wireless applications. - Highlights: • A flexible magnetoimpedance (MI) sensor is developed. • Studies are carried out using a flexible microstrip transmission line. • An MI ratio of up to 90% is obtained. • The effect of magnetostriction is studied

  18. Flexible transparent electrode

    Science.gov (United States)

    Demiryont, Hulya; Shannon, Kenneth C., III; Moorehead, David; Bratcher, Matthew

    2011-06-01

    This paper presents the properties of the EclipseTECTM transparent conductor. EclipseTECTM is a room temperature deposited nanostructured thin film coating system comprised of metal-oxide semiconductor elements. The system possesses metal-like conductivity and glass-like transparency in the visible region. These highly conductive TEC films exhibit high shielding efficiency (35dB at 1 to 100GHz). EclipseTECTM can be deposited on rigid or flexible substrates. For example, EclipseTECTM deposited on polyethylene terephthalate (PET) is extremely flexible that can be rolled around a 9mm diameter cylinder with little or no reduction in electrical conductivity and that can assume pre-extension states after an applied stress is relieved. The TEC is colorless and has been tailored to have high visible transmittance which matches the eye sensitivity curve and allows the viewing of true background colors through the coating. EclipseTECTM is flexible, durable and can be tailored at the interface for applications such as electron- or hole-injecting OLED electrodes as well as electrodes in flexible displays. Tunable work function and optical design flexibility also make EclipseTECTM well-suited as a candidate for grid electrode replacement in next-generation photovoltaic cells.

  19. Flexible Foam Model.

    Energy Technology Data Exchange (ETDEWEB)

    Neilsen, Michael K.; Lu, Wei-Yang; Werner, Brian T.; Scherzinger, William M.; Lo, Chi S.

    2018-03-01

    Experiments were performed to characterize the mechanical response of a 15 pcf flexible polyurethane foam to large deformation at different strain rates and temperatures. Results from these experiments indicated that at room temperature, flexible polyurethane foams exhibit significant nonlinear elastic deformation and nearly return to their original undeformed shape when unloaded. However, when these foams are cooled to temperatures below their glass transition temperature of approximately -35 o C, they behave like rigid polyurethane foams and exhibit significant permanent deformation when compressed. Thus, a new model which captures this dramatic change in behavior with temperature was developed and implemented into SIERRA with the name Flex_Foam to describe the mechanical response of both flexible and rigid foams to large deformation at a variety of temperatures and strain rates. This report includes a description of recent experiments. Next, development of the Flex Foam model for flexible polyurethane and other flexible foams is described. Selection of material parameters are discussed and finite element simulations with the new Flex Foam model are compared with experimental results to show behavior that can be captured with this new model.

  20. Incentivizing Flexibility in System Operations

    Energy Technology Data Exchange (ETDEWEB)

    Milligan, Michael [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Bloom, Aaron P [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Townsend, Aaron [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Ela, Erik [Electric Power Research Institute; Botterud, Audun [Argonne National Laboratory; Levin, Todd [Argonne National Laboratory

    2018-02-15

    Defining flexibility has been a challenge that a number of industry members and researchers have attempted to address in recent years. With increased variability and uncertainty of variable generation (VG), the resources on the system will have to be more flexible to adjust output, so that power output ranges, power ramp rates, and energy duration sustainability are sufficient to meet the needs of balancing supply with demand at various operational timescales. This chapter discusses whether existing market designs provide adequate incentives for resources to offer their flexibility into the market to meet the increased levels of variability and uncertainty introduced by VG in the short-term operational time frame. It presents a definition of flexibility and discusses how increased levels of VG require increased needs for flexibility on power systems. Following this introductory material, the chapter examines how existing market designs ensure that resources have the right incentives to provide increased flexibility, and then discusses a number of emerging market design elements that impact flexibility incentives.

  1. Study for on-line system to identify inadvertent control rod drops in PWR reactors using ex-core detector and thermocouple measures

    International Nuclear Information System (INIS)

    Souza, Thiago J.; Medeiros, Jose A.C.C.; Goncalves, Alessandro C.

    2015-01-01

    Accidental control rod drops event in PWR reactors leads to an unsafe operating condition. It is important to quickly identify the rod to minimize undesirable effects in such a scenario. In this event, there is a distortion in the power distribution and temperature in the reactor core. The goal of this study is to develop an on-line model to identify the inadvertent control rod dropped in PWR reactor. The proposed model is based on physical correlations and pattern recognition of ex-core detector responses and thermocouples measures. The results of the study demonstrated the feasibility of an on-line system, contributing to safer operation conditions and preventing undesirable effects, as its shutdown. (author)

  2. Study for on-line system to identify inadvertent control rod drops in PWR reactors using ex-core detector and thermocouple measures

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Thiago J.; Medeiros, Jose A.C.C.; Goncalves, Alessandro C., E-mail: tsouza@nuclear.ufrj.br, E-mail: canedo@lmp.ufrj.br, E-mail: alessandro@nuclear.ufrj.br [Coordenacao dos Programas de Pos-Graduacao em Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear

    2015-07-01

    Accidental control rod drops event in PWR reactors leads to an unsafe operating condition. It is important to quickly identify the rod to minimize undesirable effects in such a scenario. In this event, there is a distortion in the power distribution and temperature in the reactor core. The goal of this study is to develop an on-line model to identify the inadvertent control rod dropped in PWR reactor. The proposed model is based on physical correlations and pattern recognition of ex-core detector responses and thermocouples measures. The results of the study demonstrated the feasibility of an on-line system, contributing to safer operation conditions and preventing undesirable effects, as its shutdown. (author)

  3. Graphene-based materials for flexible supercapacitors.

    Science.gov (United States)

    Shao, Yuanlong; El-Kady, Maher F; Wang, Lisa J; Zhang, Qinghong; Li, Yaogang; Wang, Hongzhi; Mousavi, Mir F; Kaner, Richard B

    2015-06-07

    The demand for flexible/wearable electronic devices that have aesthetic appeal and multi-functionality has stimulated the rapid development of flexible supercapacitors with enhanced electrochemical performance and mechanical flexibility. After a brief introduction to flexible supercapacitors, we summarize current progress made with graphene-based electrodes. Two recently proposed prototypes for flexible supercapacitors, known as micro-supercapacitors and fiber-type supercapacitors, are then discussed. We also present our perspective on the development of graphene-based electrodes for flexible supercapacitors.

  4. Flexible small size radiofrequency plasma torch for Tokamak wall cleaning

    International Nuclear Information System (INIS)

    Eusebiu-Rosini Ionita; Luciu, I.; Dinescu, G.; Grisolia, Ch.

    2006-01-01

    Tritium accumulation in walls is a limiting factor in efficient long term operation of fusion machines. A number of detritiation techniques are under study, like laser, discharge, flash lamp based cleaning. One of the encountered difficulties is the limited access of the detritiation tool in narrow spaces, as in divertor region, inter-tiles or inside castellated gaps, where in fact an enhanced co-deposition and tritium trapping were observed. This contribution addresses the problem of elaboration of plasma torch as a tool appropriate for stimulating detritiation and removal of co-deposited layers in such spaces. The requirements imposed to the plasma torch source were related to the compatibility with inside torus operation: small diameter in order to permit access in narrow spaces, reasonable power, large range of working pressures from vacuum to atmosphere, closed loop cooling, flexibility in order to allow scanning and mounting on a robotic arm. The approached design is based on a radiofrequency discharge constricted to burn in a closed space between an active radiofrequency electrode and a grounded nozzle, from where plasma expands outside as a directional beam. The found solutions have led to a flexible hand held source working stable up to 300 W injected power and consisting of a cylindrical body of 20 mm diameter including the external water jacket embracing the discharge and an inside cooling circuit. The electrical characterization of the radiofrequency discharge sustaining the expanded plasma was performed and the domain of stable source operation in terms of power, current, pressure, argon mass flow rate is presented and discussed. The plasma beam size presents a strong dependence on pressure: the plasma length decreases from 200 mm to 20 mm, when pressure increases from vacuum to atmospheric, depending on power and mass flow rate. The ionized gas temperature, as indicated by a thermocouple head inserted in expansion in the nozzle proximity fall in the

  5. Flexible Metal Oxide/Graphene Oxide Hybrid Neuromorphic Devices on Flexible Conducting Graphene Substrates

    OpenAIRE

    Wan, Chang Jin; Wang, Wei; Zhu, Li Qiang; Liu, Yang Hui; Feng, Ping; Liu, Zhao Ping; Shi, Yi; Wan, Qing

    2016-01-01

    Flexible metal oxide/graphene oxide hybrid multi-gate neuron transistors were fabricated on flexible graphene substrates. Dendritic integrations in both spatial and temporal modes were successfully emulated, and spatiotemporal correlated logics were obtained. A proof-of-principle visual system model for emulating lobula giant motion detector neuron was investigated. Our results are of great interest for flexible neuromorphic cognitive systems.

  6. Flexible Electronics Research Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Flexible Electronics Research Facility designs, synthesizes, tests, and fabricates materials and devices compatible with flexible substrates for Army information...

  7. Flexibility within Fidelity

    Science.gov (United States)

    Kendall, Philip C.; Gosch, Elizabeth; Furr, Jami M.; Sood, Erica

    2008-01-01

    The authors address concerns regarding manual-based treatments, highlighting the role of flexibility and creativity. A cognitive-behavioral therapy for youth anxiety called the Coping Cat program demonstrates the flexible application of manuals and emphasizes the importance of a child-centered, personalized approach that involves the child in the…

  8. WAGE FLEXIBILITY IN THE CONTEMPORARY SOCIETY

    Directory of Open Access Journals (Sweden)

    TECULESCU Silviu Alexandru

    2010-12-01

    Full Text Available The paper follows to offer the most efficient solutions for the attainment by Romania of the economic development level associated to the Western European countries. It proposes the division of the flexibility of labour market in three components, namely: internal flexibility, external flexibility and wage flexibility. The analysis performed within the present study will emphasize the wage flexibility. Wage flexibility can be classified in four components: a plans of individual and group incentives; b plans of assigning wages out of productivity; c plans of distribution of profits and, respectively, d plans of suggestions. The labour market flexibility, in general, and especially the wage flexibility contributes to the increase of employee motivation at the workplace, aspect which leeds to the growth of labour productivity, through this one being put the bases of the medium- and long-term economic development.

  9. Energy Flexibility in the Power System

    DEFF Research Database (Denmark)

    Billanes, Joy Dalmacio; Ma, Zheng; Jørgensen, Bo Nørregaard

    2017-01-01

    Energy flexibility can address the challenges of large scale integration of renewable energy resources and thereby increasing imbalance in the power system. Flexible power system can provide reliable supply, low electricity cost and sustainability. Various situations and factors influence...... the adoption of the flexibility solutions, such as flexible electricity generation, demand-response, and electricity storage. This paper tries to analyze the current energy flexibility solutions and the factors that can influence the energy flexibility adoption. This paper takes Philippines as case study...... to provide an overview of the current condition of the Philippines’ power system and discuss the energy flexibility in the Philippines’ power system. A further discussion and recommendation is conducted in the end of the paper....

  10. Organizational flexibility estimation

    OpenAIRE

    Komarynets, Sofia

    2013-01-01

    By the help of parametric estimation the evaluation scale of organizational flexibility and its parameters was formed. Definite degrees of organizational flexibility and its parameters for the Lviv region enterprises were determined. Grouping of the enterprises under the existing scale was carried out. Special recommendations to correct the enterprises behaviour were given.

  11. Inter-Vertebral Flexibility of the Ostrich Neck: Implications for Estimating Sauropod Neck Flexibility

    OpenAIRE

    Cobley, Matthew J.; Rayfield, Emily J.; Barrett, Paul M.

    2013-01-01

    The flexibility and posture of the neck in sauropod dinosaurs has long been contentious. Improved constraints on sauropod neck function will have major implications for what we know of their foraging strategies, ecology and overall biology. Several hypotheses have been proposed, based primarily on osteological data, suggesting different degrees of neck flexibility. This study attempts to assess the effects of reconstructed soft tissues on sauropod neck flexibility through systematic removal o...

  12. Flexible automated manufacturing for SMEs

    DEFF Research Database (Denmark)

    Grube Hansen, David; Bilberg, Arne; Madsen, Erik Skov

    2017-01-01

    SMEs are in general highly flexible and agile in order to accommodate the customer demands in the paradigm of High Mix-Low Volume manufacturing. The flexibility and agility have mainly been enabled by manual labor, but as we are entering the technology and data driven fourth industrial revolution......, where augmented operators and machines work in cooperation in a highly flexible and productive manufacturing system both an opportunity and a need has raised for developing highly flexible and efficient automation....

  13. On flexible and rigid nouns

    DEFF Research Database (Denmark)

    Rijkhoff, Jan

    2010-01-01

    classes. Finally this article wants to claim that the distinction between rigid and flexible noun categories (a) adds a new dimension to current classifications of parts of speech systems, (b) correlates with certain grammatical phenomena (e.g. so-called number discord), and (c) helps to explain the parts......This article argues that in addition to the major flexible lexical categories in Hengeveld’s classification of parts of speech systems (Contentive, Non-Verb, Modifier), there are also flexible word classes within the rigid lexical category Noun (Set Noun, Sort Noun, General Noun). Members...... by the flexible item in the external world. I will then argue that flexible word classes constitute a proper category (i.e. they are not the result of a merger of some rigid word classes) in that members of flexible word categories display the same properties regarding category membership as members of rigid word...

  14. On flexible and rigid nouns

    DEFF Research Database (Denmark)

    Rijkhoff, Jan

    2008-01-01

    Studies in Language 32-3 (2008), 727-752. Special issue: Parts of Speech: Descriptive tools, theoretical constructs Jan Rijkhoff - On flexible and rigid nouns This article argues that in addition to the flexible lexical categories in Hengeveld’s classification of parts-of-speech systems (Contentive......, Non-Verb, Modifier), there are also flexible word classes within the rigid lexical category Noun (Set Noun, Sort Noun, General Noun). Members of flexible word classes are characterized by their vague semantics, which in the case of nouns means that values for the semantic features Shape...... and Homogeneity are either left undetermined or they are specified in such a way that they do not quite match the properties of the kind of entity denoted by the flexible item in the external world. I will then argue that flexible word classes constitute a proper category (i.e. they are not the result of a merger...

  15. Flexible magnetoimpidence sensor

    KAUST Repository

    Kavaldzhiev, Mincho

    2015-05-01

    Recently, flexible electronic devices have attracted increasing interest, due to the opportunities they promise for new applications such as wearable devices, where the components are required to flex during normal use[1]. In this light, different magnetic sensors, like microcoil, spin valve, giant magnetoresistance (GMR), magnetoimpedance (MI), have been studied previously on flexible substrates.

  16. Global Analysis of Flexible Risers

    DEFF Research Database (Denmark)

    Banke, Lars

    1996-01-01

    Flexible pipes are often a technically attractive alternative to the traditional steel pipe. Often commercial utilisation of oil/gas fields depends on the use of flexible pipes. An example is when floating production vessels are used, where the flexible pipe follows the wave induced motions...

  17. Designing structural supply chain flexibility

    NARCIS (Netherlands)

    Mulinski, Ksawery Jan

    2012-01-01

    In a continuously changing business environment the role of supply chain flexibility is constantly increasing. A flexible supply chain can ensure survival in quickly changing market conditions as well as enable sustainable growth. This thesis explores the topic of supply chain flexibility with focus

  18. Flexibility in insulin prescription

    Directory of Open Access Journals (Sweden)

    Sanjay Kalra

    2016-01-01

    Full Text Available This communication explores the concept of flexibility, a propos insulin preparations and insulin regimes used in the management of type 2 diabetes. The flexibility of an insulin regime or preparation is defined as their ability to be injected at variable times, with variable injection-meal time gaps, in a dose frequency and quantum determined by shared decision making, with a minimal requirement of glucose monitoring and health professional consultation, with no compromise on safety, efficiency and tolerability. The relative flexibility of various basal, prandial and dual action insulins, as well as intensive regimes, is compared. The biopsychosocial model of health is used to assess the utility of different insulins while encouraging a philosophy of flexible insulin usage.

  19. Education for Flexible Personality

    Directory of Open Access Journals (Sweden)

    Bogomir Novak

    1998-12-01

    Full Text Available Flexible personality transforms both cultural environment and itself. Post-modern personality is both contemplative and active. On one hand, it is subject to inner imagination of a creative act, and on the other hand, to creation of a tangible product What is more, flexible personality is also autonomous, mature, healthy and well balanced, as well as stable and responsive to the demand for change. Due to ever quicker changes, flexible personality is a must. And it is a task. The impact of professional work of adults on the education of children, however, is being conditioned by the exrigid family and rigid enterprises or institutions in which adults are employed. Nevertheless, flexible educational style is not repressive, as it used to be, nor permissive and totally concentrated on the child. It is a choice between the two qualities. The educators' style is dependent on their attitude towards life (play and self-education and not only towards work. Nowadays, flexibility is a way towards quality management of social and personal changes.

  20. Graphene-cellulose paper flexible supercapacitors

    Energy Technology Data Exchange (ETDEWEB)

    Weng, Zhe; Su, Yang; Li, Feng; Du, Jinhong; Cheng, Hui-Ming [Shenyang National Laboratory for Materials Science, Institute of Metal Research, Chinese Academy of Sciences, 72 Wenhua Road, Shenyang 110016 (China); Wang, Da-Wei [ARC Centre of Excellence for Functional Nanomaterials, Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, St Lucia, Brisbane, Qld 4072 (Australia)

    2011-10-15

    A simple and scalable method to fabricate graphene-cellulose paper (GCP) membranes is reported; these membranes exhibit great advantages as freestanding and binder-free electrodes for flexible supercapacitors. The GCP electrode consists of a unique three-dimensional interwoven structure of graphene nanosheets and cellulose fibers and has excellent mechanical flexibility, good specific capacitance and power performance, and excellent cyclic stability. The electrical conductivity of the GCP membrane shows high stability with a decrease of only 6% after being bent 1000 times. This flexible GCP electrode has a high capacitance per geometric area of 81 mF cm{sup -2}, which is equivalent to a gravimetric capacitance of 120 F g{sup -1} of graphene, and retains >99% capacitance over 5000 cycles. Several types of flexible GCP-based polymer supercapacitors with various architectures are assembled to meet the power-energy requirements of typical flexible or printable electronics. Under highly flexible conditions, the supercapacitors show a high capacitance per geometric area of 46 mF cm{sup -2} for the complete devices. All the results demonstrate that polymer supercapacitors made using GCP membranes are versatile and may be used for flexible and portable micropower devices. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  1. Three-dimensional formulation of rigid-flexible multibody systems with flexible beam elements

    International Nuclear Information System (INIS)

    Garcia-Vallejo, D.; Mayo, J.; Escalona, J. L.; Dominguez, J.

    2008-01-01

    Multibody systems generally contain solids with appreciable deformations and which decisively influence the dynamics of the system. These solids have to be modeled by means of special formulations for flexible solids. At the same time, other solids are of such a high stiffness that they may be considered rigid, which simplifies their modeling. For these reasons, for a rigid-flexible multibody system, two types of formulations coexist in the equations of the system. Among the different possibilities provided in the literature on the material, the formulation in natural coordinates and the formulation in absolute nodal coordinates are utilized in this paper to model the rigid and flexible solids, respectively. This paper contains a mixed formulation based on the possibility of sharing coordinates between a rigid solid and a flexible solid. The global mass matrix of the system is shown to be constant and, in addition, many of the constraint equations obtained upon utilizing these formulations are linear and can be eliminated

  2. Development of the Coping Flexibility Scale: Evidence for the Coping Flexibility Hypothesis

    Science.gov (United States)

    Kato, Tsukasa

    2012-01-01

    "Coping flexibility" was defined as the ability to discontinue an ineffective coping strategy (i.e., evaluation coping) and produce and implement an alternative coping strategy (i.e., adaptive coping). The Coping Flexibility Scale (CFS) was developed on the basis of this definition. Five studies involving approximately 4,400 Japanese…

  3. Construção e avaliação de psicrômetro aspirado de termopar Construction and evaluation of an aspirated thermocouple psychrometer

    Directory of Open Access Journals (Sweden)

    Fábio Ricardo Marin

    2001-12-01

    Full Text Available Construiu-se um psicrômetro de termopar aspirado, de baixo custo e fácil utilização em sistemas automáticos de aquisição de dados, utilizando-se tubos de PVC. A aspiração foi feita por ventiladores utilizados em microcomputadores e as temperaturas foram determinadas com junções de termopar de cobre-constantan. Para umidecimento do bulbo, utilizou-se um cordão de algodão. Os resultados da comparação com higrômetro capacitivo Vaisala Inc. e com psicrômetro aspirado tipo Assman mostraram que tanto em ambientes naturais como em controlados, a precisão e a exatidão das medidas foi muito boa, de maneira que o psicrômetro aqui descrito pode ser empregado para determinação da pressão atual de vapor e da umidade relativa sem perda de qualidade dos dados, e também em estudos que levem em conta gradientes de temperatura e umidade específica.The construction of a low cost aspirated thermocouple psychrometer made of PVC tubes is described. The instrument can easily be connected to dataloggers. The aspiration is made by fans used in microcomputers and temperatures measured with cooper-constantan thermocouples. A cotton string was used to make the wet junction. Its perfomance was evaluated in comparison to an Assman aspirated psychrometer and a Vaisala Inc. capacitive higrometer, in natural and controlled environments. The results show a good agreement between measures, allowing air vapour, relative humidity, temperature and specific humidity gradients to be determined using the proposed psychrometer.

  4. The Flexibility of Pusher Furnace Grate

    Directory of Open Access Journals (Sweden)

    Słowik J.A.

    2016-12-01

    Full Text Available The lifetime of guide grates in pusher furnaces for heat treatment could be increased by raising the flexibility of their structure through, for example, the replacement of straight ribs, parallel to the direction of grate movement, with more flexible segments. The deformability of grates with flexible segments arranged in two orientations, i.e. crosswise (perpendicular to the direction of compression and lengthwise (parallel to the direction of compression, was examined. The compression process was simulated using SolidWorks Simulation program. Relevant regression equations were also derived describing the dependence of force inducing the grate deformation by 0.25 mm ‒ modulus of grate elasticity ‒ on the number of flexible segments in established orientations. These calculations were made in Statistica and Scilab programs. It has been demonstrated that, with the same number of segments, the crosswise orientation of flexible segments increases the grate structure flexibility in a more efficient way than the lengthwise orientation. It has also been proved that a crucial effect on the grate flexibility has only the quantity and orientation of segments (crosswise / lengthwise, while the exact position of segments changes the grate flexibility by less than 1%.

  5. High Performance Electronics on Flexible Silicon

    KAUST Repository

    Sevilla, Galo T.

    2016-09-01

    Over the last few years, flexible electronic systems have gained increased attention from researchers around the world because of their potential to create new applications such as flexible displays, flexible energy harvesters, artificial skin, and health monitoring systems that cannot be integrated with conventional wafer based complementary metal oxide semiconductor processes. Most of the current efforts to create flexible high performance devices are based on the use of organic semiconductors. However, inherent material\\'s limitations make them unsuitable for big data processing and high speed communications. The objective of my doctoral dissertation is to develop integration processes that allow the transformation of rigid high performance electronics into flexible ones while maintaining their performance and cost. In this work, two different techniques to transform inorganic complementary metal-oxide-semiconductor electronics into flexible ones have been developed using industry compatible processes. Furthermore, these techniques were used to realize flexible discrete devices and circuits which include metal-oxide-semiconductor field-effect-transistors, the first demonstration of flexible Fin-field-effect-transistors, and metal-oxide-semiconductors-based circuits. Finally, this thesis presents a new technique to package, integrate, and interconnect flexible high performance electronics using low cost additive manufacturing techniques such as 3D printing and inkjet printing. This thesis contains in depth studies on electrical, mechanical, and thermal properties of the fabricated devices.

  6. Workplace flexibility: from research to action.

    Science.gov (United States)

    Galinsky, Ellen; Sakai, Kelly; Wigton, Tyler

    2011-01-01

    Ellen Galinsky, Kelly Sakai, and Tyler Wigton explore the "time famine" among American workers-the continuing sense among employees of not having enough time to manage the multiple responsibilities of work and personal and family life. Noting that large shares of U.S. employees report feeling the need for greater workplace flexibility to enable them to take better care of family responsibilities, the authors examine a large-scale community-engagement initiative to increase workplace flexibility voluntarily. Using the 2008 National Study of the Changing Workforce as a primary source of data, the authors begin with an overview of the prevalence of flexibility in today's American workplace. They track which categories of employees have access to various flexibility options, as well as the extent to which employees with access to various types of flexibility use those options. Findings from the study indicate that the majority of employees want flexibility but that access to it varies, with more advantaged employees--those who are well educated, have high salaries, and work full time, for example--being doubly advantaged in having greater access to flexibility. A number of employers, say the authors, tend to be skeptical of the value of workplace flexibility and to fear that employees will abuse it if it is offered. But the study data reveal that most employees use flexibility quite conservatively. When the authors use their nationally representative data set to investigate correlations between access to workplace flexibility and a range of workplace outcomes especially valued by employers--employee engagement, job satisfaction, retention, and health--they find that employers as well as employees can benefit from flexibility. Finally, the authors discuss When Work Works, a large, national community-based initiative under way since 2003 to increase voluntary adoption of workplace flexibility. The authors detail the conceptual basis of the project's design, noting its

  7. Free-form Flexible Lithium-Ion Microbattery

    KAUST Repository

    Kutbee, Arwa T.; Ghoneim, Mohamed T.; Ahmed, Sally; Hussain, Muhammad Mustafa

    2016-01-01

    Wearable electronics need miniaturized, safe and flexible power sources. Lithium ion battery is a strong candidate as high performance flexible battery. The development of flexible materials for battery electrodes suffers from the limited material

  8. Cognitive Flexibility in Obsessive Compulsive Disorder

    DEFF Research Database (Denmark)

    Jónsson, Hjalti; Salkovskis, Paul M.

    BT for problems such as OCD requires a level of cognitive flexibility (that is the ability to take a different perspective on ones problems). It could be argued that problems in set shifting (by neuropsychological tests) might underpin problems in this area. Two assessments were used (1: perception...... of cognitive flexibility was assessed by questionnaire 2: neuropsychological evaluation of set shifting). This study will recruit three groups: OCD patients, anxious and healthy controls. Cognitive flexibility is measured using modified version of the Cognitive Flexibility Scale (Martin & Rubin, 1995......) and neuropsychological measures of cognitive flexibility (Wisconsin Cart Sorting Test, Trail Making Test A/B, The Brixton Test). IN addition to the group comparison, the relationship between perceived flexibility, set shifting and psychopathology will be investigated. The implications of the findings for treatment...

  9. Flexible packaging for PV modules

    Science.gov (United States)

    Dhere, Neelkanth G.

    2008-08-01

    Economic, flexible packages that provide needed level of protection to organic and some other PV cells over >25-years have not yet been developed. However, flexible packaging is essential in niche large-scale applications. Typical configuration used in flexible photovoltaic (PV) module packaging is transparent frontsheet/encapsulant/PV cells/flexible substrate. Besides flexibility of various components, the solder bonds should also be flexible and resistant to fatigue due to cyclic loading. Flexible front sheets should provide optical transparency, mechanical protection, scratch resistance, dielectric isolation, water resistance, UV stability and adhesion to encapsulant. Examples are Tefzel, Tedlar and Silicone. Dirt can get embedded in soft layers such as silicone and obscure light. Water vapor transmittance rate (WVTR) of polymer films used in the food packaging industry as moisture barriers are ~0.05 g/(m2.day) under ambient conditions. In comparison, light emitting diodes employ packaging components that have WVTR of ~10-6 g/(m2.day). WVTR of polymer sheets can be improved by coating them with dense inorganic/organic multilayers. Ethylene vinyl acetate, an amorphous copolymer used predominantly by the PV industry has very high O2 and H2O diffusivity. Quaternary carbon chains (such as acetate) in a polymer lead to cleavage and loss of adhesional strength at relatively low exposures. Reactivity of PV module components increases in presence of O2 and H2O. Adhesional strength degrades due to the breakdown of structure of polymer by reactive, free radicals formed by high-energy radiation. Free radical formation in polymers is reduced when the aromatic rings are attached at regular intervals. This paper will review flexible packaging for PV modules.

  10. Flexible devices: from materials, architectures to applications

    Science.gov (United States)

    Zou, Mingzhi; Ma, Yue; Yuan, Xin; Hu, Yi; Liu, Jie; Jin, Zhong

    2018-01-01

    Flexible devices, such as flexible electronic devices and flexible energy storage devices, have attracted a significant amount of attention in recent years for their potential applications in modern human lives. The development of flexible devices is moving forward rapidly, as the innovation of methods and manufacturing processes has greatly encouraged the research of flexible devices. This review focuses on advanced materials, architecture designs and abundant applications of flexible devices, and discusses the problems and challenges in current situations of flexible devices. We summarize the discovery of novel materials and the design of new architectures for improving the performance of flexible devices. Finally, we introduce the applications of flexible devices as key components in real life. Project supported by the National Key R&D Program of China (Nos. 2017YFA0208200, 2016YFB0700600, 2015CB659300), the National Natural Science Foundation of China (Nos. 21403105, 21573108), and the Fundamental Research Funds for the Central Universities (No. 020514380107).

  11. Developmental constraints on behavioural flexibility.

    Science.gov (United States)

    Holekamp, Kay E; Swanson, Eli M; Van Meter, Page E

    2013-05-19

    We suggest that variation in mammalian behavioural flexibility not accounted for by current socioecological models may be explained in part by developmental constraints. From our own work, we provide examples of constraints affecting variation in behavioural flexibility, not only among individuals, but also among species and higher taxonomic units. We first implicate organizational maternal effects of androgens in shaping individual differences in aggressive behaviour emitted by female spotted hyaenas throughout the lifespan. We then compare carnivores and primates with respect to their locomotor and craniofacial adaptations. We inquire whether antagonistic selection pressures on the skull might impose differential functional constraints on evolvability of skulls and brains in these two orders, thus ultimately affecting behavioural flexibility in each group. We suggest that, even when carnivores and primates would theoretically benefit from the same adaptations with respect to behavioural flexibility, carnivores may nevertheless exhibit less behavioural flexibility than primates because of constraints imposed by past adaptations in the morphology of the limbs and skull. Phylogenetic analysis consistent with this idea suggests greater evolutionary lability in relative brain size within families of primates than carnivores. Thus, consideration of developmental constraints may help elucidate variation in mammalian behavioural flexibility.

  12. Flexible Thermoelectric Generators on Silicon Fabric

    KAUST Repository

    Sevilla, Galo T.

    2012-01-01

    In this work, the development of a Thermoelectric Generator on Flexible Silicon Fabric is explored to extend silicon electronics for flexible platforms. Low cost, easily deployable plastic based flexible electronics are of great interest for smart

  13. The Flexibility of Organization and the flexibility of product – premises of organizational success

    OpenAIRE

    Todorut, Amalia Venera

    2008-01-01

    Flexibility represents the ability of a manufactural system to adapt to some diversified tasks of production, thus to assure an economic efficiency – the rapport time/cost should be optimum, with insignificant structure changes within a long period of time. The central role of flexibility is to permit the survival and the success of the organizations in a turbulent circumstance, which is characteristic to the new world tendencies. The more flexible the organization becomes, the better it resp...

  14. Contagious flexibility? A study on whether schedule flexibility facilitates work-life enrichment.

    Science.gov (United States)

    Pedersen, Vivi Bach; Jeppesen, Hans Jeppe

    2012-08-01

    Schedule flexibility defines an important generating resource for work-life enrichment; however, our knowledge about how such spillovers take place is limited. This multiple case study examines how workers from different working time contexts with varying levels of schedule flexibility experience work-life interplay. Given the adopted explorative design, it is important to interpret the findings in a tentative light. Nonetheless, the study offers important insight into work-life enrichment that may guide future research in this field. The findings indicate that schedule flexibility may act as a boundary-spanning resource owing to the agency potential it offers workers. Thus, it seemed that flexible schedule opportunities enabled workers to engage more fully in personal life activities, which in turn had a positive influence on their work involvement through positive affect. Such positive role engagements appeared, however, to be greatly determined by workers' boundary management and by time conditions of work and family. In conclusion, the major findings and limitation of the study are discussed against existing research and theory. © 2012 The Authors. Scandinavian Journal of Psychology © 2012 The Scandinavian Psychological Associations.

  15. UNITY OF THE ORGANIZATIONAL FUNCTIONS FLEXIBILITY

    OpenAIRE

    George MOLDOVEANU; Cosmin DOBRIN

    2012-01-01

    The paper has the goal to analyse the correlation of the flexibility of all organizational functions. Based upon theoretical and practical studies, the decrease of flexibility into an "activity area" of organizations implies a diminution on a large scale of the flexibility of the processing system as a law expression of the decreasing outputs within economy. Therefore, at the level of each organizational function there are several major directions ensuring the flexibility of the "ensemble".

  16. Flexible barrier technology for enabling rollable AMOLED displays and upscaling flexible OLED lighting

    NARCIS (Netherlands)

    Li, F.M.; Unnikrishnan, S.; Weijer, P. van de; Assche, F. van; Shen, J.; Ellis, T.; Manders, W.; Akkerman, H.; Bouten, P.; Mol, A.M.B. van

    2013-01-01

    The availability of a high performance thin-film barrier is the most critical challenge in upscaling and commercializing flexible OLED products. We report a flexible thin-film-barrier technology that meets lifetime specifications for OLED lighting, and demonstrate it in rollable QVGA a-IGZO AMOLED

  17. Intrinsic flexibility of porous materials; theory, modelling and the flexibility window of the EMT zeolite framework

    International Nuclear Information System (INIS)

    Fletcher, Rachel E.; Wells, Stephen A.; Leung, Ka Ming; Edwards, Peter P.; Sartbaeva, Asel

    2015-01-01

    Framework materials possess intrinsic flexibility which can be investigated using geometric simulation. We review framework flexibility properties in energy materials and present novel results on the flexibility window of the EMT zeolite framework containing 18-crown-6 ether as a structure directing agent (SDA). Framework materials have structures containing strongly bonded polyhedral groups of atoms connected through their vertices. Typically the energy cost for variations of the inter-polyhedral geometry is much less than the cost of distortions of the polyhedra themselves – as in the case of silicates, where the geometry of the SiO 4 tetrahedral group is much more strongly constrained than the Si—O—Si bridging angle. As a result, framework materials frequently display intrinsic flexibility, and their dynamic and static properties are strongly influenced by low-energy collective motions of the polyhedra. Insight into these motions can be obtained in reciprocal space through the ‘rigid unit mode’ (RUM) model, and in real-space through template-based geometric simulations. We briefly review the framework flexibility phenomena in energy-relevant materials, including ionic conductors, perovskites and zeolites. In particular we examine the ‘flexibility window’ phenomenon in zeolites and present novel results on the flexibility window of the EMT framework, which shed light on the role of structure-directing agents. Our key finding is that the crown ether, despite its steric bulk, does not limit the geometric flexibility of the framework

  18. Optimized flexible cover films for improved conversion efficiency in thin film flexible solar cells

    Science.gov (United States)

    Guterman, Sidney; Wen, Xin; Gudavalli, Ganesh; Rhajbhandari, Pravakar; Dhakal, Tara P.; Wilt, David; Klotzkin, David

    2018-05-01

    Thin film solar cell technologies are being developed for lower cost and flexible applications. For such technologies, it is desirable to have inexpensive, flexible cover strips. In this paper, we demonstrate that transparent silicone cover glass adhesive can be doped with TiO2 nanoparticles to achieve an optimal refractive index and maximize the performance of the cell. Cells covered with the film doped with nanoparticles at the optimal concentration demonstrated a ∼1% increase in photocurrent over the plain (undoped) film. In addition, fused silica beads can be incorporated into the flexible cover slip to realize a built-in pseudomorphic glass diffuser layer as well. This additional degree of freedom in engineering flexible solar cell covers allows maximal performance from a given cell for minimal increased cost.

  19. Free-form Flexible Lithium-Ion Microbattery

    KAUST Repository

    Kutbee, Arwa T.

    2016-03-02

    Wearable electronics need miniaturized, safe and flexible power sources. Lithium ion battery is a strong candidate as high performance flexible battery. The development of flexible materials for battery electrodes suffers from the limited material choices. In this work, we present integration strategy to rationally design materials and processes to report flexible inorganic lithium-ion microbattery with no restrictions on the materials used. The battery shows an enhanced normalized capacity of 147 μAh/cm2 when bent.

  20. Flexible Programmes in Higher Professional Education: Expert Validation of a Flexible Educational Model

    Science.gov (United States)

    Schellekens, Ad; Paas, Fred; Verbraeck, Alexander; van Merrienboer, Jeroen J. G.

    2010-01-01

    In a preceding case study, a process-focused demand-driven approach for organising flexible educational programmes in higher professional education (HPE) was developed. Operations management and instructional design contributed to designing a flexible educational model by means of discrete-event simulation. Educational experts validated the model…

  1. Flexible position probe assembly

    International Nuclear Information System (INIS)

    Schmitz, J.J.

    1977-01-01

    The combination of a plurality of tubular transducer sections and a flexible supporting member extending through the tubular transducer sections forms a flexible elongated probe of a design suitable for monitoring the level of an element, such as a nuclear magnetically permeable control rod or liquid. 3 claims, 23 figures

  2. Flexible Learning Environments: Leveraging the Affordances of Flexible Delivery and Flexible Learning

    Science.gov (United States)

    Hill, Janette R.

    2006-01-01

    The purpose of this article is to explore the key features of "flexible learning environments" (FLEs). Key principles associated with FLEs are explained. Underlying tenets and support mechanisms necessary for the implementation of FLEs are described. Similarities and differences in traditional learning and FLEs are explored. Finally, strategies…

  3. Performance measurement of supply chain flexibility using witness

    Directory of Open Access Journals (Sweden)

    Rituraj Chandrakar

    2012-10-01

    Full Text Available In today’s global scenario of intense competition and environmental uncertainty flexibility in supply chain has an important role to play for the existence of any supply chain business. A need to be responsive to the constantly changing market scenario and cater to the customer needs, a certain degree of flexibility is required, which requires the coordination of many plants to produce and deliver goods to customers located in different places, and suppliers, which provide each plant with the required components. This paper intends to measure the degree of flexibility required for a two stage supply chain and assessing both the supplier flexibility and the assembler flexibility. In this paper, nine configurations of the SC are considered resulting from the combination of the three degrees of supplier and manufacturer flexibility, i.e. no flexibility, limited flexibility and total flexibility, respectively. Simulation model representing the different flexibility configurations are evaluated and the performance of each configuration analyzed to determine the flexibility configuration suitable to a supply chain. In particular the performance analysis of lead time, work-in-process, service level and cost are measured to determine the suitable flexibility.

  4. Software industrial flexible

    OpenAIRE

    Díaz Araya, Daniel; Muñoz, Leandro; Sirerol, Daniel; Oviedo, Sandra; Ibáñez, Francisco S.

    2012-01-01

    En este trabajo se pretende investigar y proponer técnicas, métodos y tecnologías que permitan el desarrollo de software flexible en ambientes industriales. El objetivo es generar métodos y técnicas para facilitar el desarrollo de software flexible en ambientes industriales. Las áreas de investigación son los sistemas de scheduling de producción, la generación de software para plataformas de hardware abiertas y la innovación.

  5. Flexible Al-doped ZnO films grown on PET substrates using linear facing target sputtering for flexible OLEDs

    International Nuclear Information System (INIS)

    Jeong, Jin-A; Shin, Hyun-Su; Choi, Kwang-Hyuk; Kim, Han-Ki

    2010-01-01

    We report the characteristics of flexible Al-doped zinc oxide (AZO) films prepared by a plasma damage-free linear facing target sputtering (LFTS) system on PET substrates for use as a flexible transparent conducting electrode in flexible organic light-emitting diodes (OLEDs). The electrical, optical and structural properties of LFTS-grown flexible AZO electrodes were investigated as a function of dc power. We obtained a flexible AZO film with a sheet resistance of 39 Ω/□ and an average transmittance of 84.86% in the visible range although it was sputtered at room temperature without activation of the Al dopant. Due to the effective confinement of the high-density plasma between the facing AZO targets, the AZO film was deposited on the PET substrate without plasma damage and substrate heating caused by bombardment of energy particles. Moreover, the flexible OLED fabricated on the AZO/PET substrate showed performance similar to the OLED fabricated on a ITO/PET substrate in spite of a lower work function. This indicates that LFTS is a promising plasma damage-free and low-temperature sputtering technique for deposition of flexible and indium-free AZO electrodes for use in cost-efficient flexible OLEDs.

  6. Thin film heat flux sensors for accurate transient and unidirectional heat transfer analysis

    International Nuclear Information System (INIS)

    Azerou, B; Garnier, B; Lahmar, J

    2012-01-01

    Heat flux measurement is needed in many heat transfer studies. For the best unbiased heat flux sensors (HFS), the heat flux is obtained using temperature measurements at different locations and also an inverse heat conduction method (function specification...) in order to calculate the heat flux. Systematic errors can come from the uncertainty in the wire thermocouples locations and from errors in the knowledge of distances between two consecutive wire thermocouples. The main idea in this work is to use thin film thermoresistances deposited on a flexible thin polymer substrate instead of wire thermocouples welded on metallic sample. The interest of using thin film thermoresistances instead of wire thermocouples is a lower disturbance due to the smaller thickness of the thin film sensors (typically less than 1μm) and a much better knowledge of the distances between the different thin film thermoresistances which are precisely defined in the mask used for the metallic thin film pattern fabrication. In this paper, we present the fabrication of the new heat flux sensor with thin film thermoresistances, the study of the effect of the self heating (due to Joule effect in thermoresistances) and the performances of this new HFS with the comparison with classical HFS using wire thermocouples. For this study, a symmetric experimental setup is used with metallic samples equipped with an etched foil heater and both classical and new HFS. For several heating conditions, it appears that a better accuracy is always obtained with the new HFS using thin film thermoresistances.

  7. Mechanistic modelling of weak interlayers in flexible and semi-flexible road pavements: Part 2

    CSIR Research Space (South Africa)

    De Beer, Morris

    2012-04-01

    Full Text Available This paper (Part 2 of a two-part set of papers) discusses models and illustrates the adverse effects of weak layers, interlayers, laminations and/or weak interfaces in flexible and semi-flexible pavements, also incorporating lightly cemented layers...

  8. Flexible magnetoimpedance sensor

    KAUST Repository

    Li, Bodong

    2015-03-01

    Flexible magnetoimpedance (MI) sensors fabricated using a NiFe/Cu/NiFe tri-layer on Kapton substrate have been studied. A customized flexible microstrip transmission line was employed to investigate the MI sensors\\'s magnetic field and frequency responses and their dependence on the sensors\\'s deflection. For the first time, the impedance characteristic is obtained through reflection coefficient analysis over a wide range of frequencies from 0.1 MHz to 3 GHz and for deflections ranging from zero curvature to a radius of 7.2 cm. The sensor element maintains a high MI ratio of up to 90% and magnetic sensitivity of up to 9.2%/Oe over different bending curvatures. The relationship between the curvature and material composition is discussed based on the magnetostriction effect and stress simulations. The sensor\\'s large frequency range, simple fabrication process and high sensitivity provide a great potential for flexible electronics and wireless applications.

  9. THE FLEXIBILITY-AUTOMATION CORRESPONDENCE TO A VIRTUAL COMMERCIAL SOCIETY

    Directory of Open Access Journals (Sweden)

    Liliana Doble

    2012-01-01

    Full Text Available Design and operation of FMS is based on system requirement can be as productive and flexible as necessary, i.e. obtaining controlled correspondence between the degree of flexibility and automation of system.The flexibility of a FMS (Flexible Manufacturing Systems is determined by two important criteria: Flexible hardware structure of the system; Flexible software structure. Flexible hardware structure of the CS system (calculation system is determined to its turn according to three components: Flexibility of technological subsystem; Flexibility subsystem of storage, transport and handling;Flexibility of informational subsystem.

  10. Docking of flexible ligands to flexible receptors in solution by molecular dynamics simulation

    NARCIS (Netherlands)

    Mangoni, R; Roccatano, D; Di Nola, A

    1999-01-01

    In this paper, a method of simulating the docking of small flexible ligands to flexible receptors in water is reported. The method is based on molecular dynamics simulations and is an extension of an algorithm previously reported by Di Nola et al, (Di Nola et al,, Proteins 1994;19:174-182), The

  11. Aggregating and Disaggregating Flexibility Objects

    DEFF Research Database (Denmark)

    Siksnys, Laurynas; Valsomatzis, Emmanouil; Hose, Katja

    2015-01-01

    In many scientific and commercial domains we encounter flexibility objects, i.e., objects with explicit flexibilities in a time and an amount dimension (e.g., energy or product amount). Applications of flexibility objects require novel and efficient techniques capable of handling large amounts...... and aiming at energy balancing during aggregation. In more detail, this paper considers the complete life cycle of flex-objects: aggregation, disaggregation, associated requirements, efficient incremental computation, and balance aggregation techniques. Extensive experiments based on real-world data from...

  12. Distributed flexibility in inertial swimmers

    Science.gov (United States)

    Floryan, Daniel; Rowley, Clarence W.; Smits, Alexander J.

    2017-11-01

    To achieve fast and efficient swimming, the flexibility of the propulsive surfaces is an important feature. To better understand the effects of distributed flexibility (either through inhomogeneous material properties, varying geometry, or both) we consider the coupled solid and fluid mechanics of the problem. Here, we develop a simplified model of a flexible swimmer, using Euler-Bernoulli theory to describe the solid, Theodorsen's theory to describe the fluid, and a Blasius boundary layer to incorporate viscous effects. Our primary aims are to understand how distributed flexibility affects the thrust production and efficiency of a swimmer with imposed motion at its leading edge. In particular, we examine the modal shapes of the swimmer to gain physical insight into the observed trends. Supported under ONR MURI Grant N00014-14-1-0533, Program Manager Robert Brizzolara.

  13. Flexibility of trunnion piping elbows

    International Nuclear Information System (INIS)

    Lewis, G.D.; Chao, Y.J.

    1987-01-01

    Flexibility factors and stress indices for piping component such as straight pipe, elbows, butt-welding tees, branch connections, and butt-welding reducers are contained in the code, but many of the less common piping components, like the trunnion elbow, do not have flexibility factors or stress indices defined. The purpose of this paper is to identify the in-plane and out-of-plane flexibility factors in accordance with code procedures for welded trunnions attached to the tangent centerlines of long radius elbows. This work utilized the finite element method as applicable to plates and shells for calculating the relative rotations of the trunnion elbow-ends for in-plane and out-of-plane elbow moment loadings. These rotations are used to derive the corresponding in-plane and out-of-plane flexibility factors. (orig./GL)

  14. Work Life Balance in the Netherlands: Flexible working hours and a flexible working place (Japanese)

    OpenAIRE

    KENJOH Eiko

    2011-01-01

    The purpose of this paper is to investigate the nature of Dutch approach to achieving Work Life Balance (WLB) and to draw policy implications for Japan. It is argued that flexibility of working hours and flexibility offered at one's working place are essential elements of WLB. In this respect, the Netherlands has attained relatively advanced policies and practices. For instance, workers in the Netherlands enjoy a strong degree of flexibility in terms of working hours, a system that strives to...

  15. Business Models for Power System Flexibility

    DEFF Research Database (Denmark)

    Boscan, Luis; Poudineh, Rahmatallah

    2016-01-01

    As intermittent, renewable resources gain more share in the generation mix, the need for power system flexibility increases more than ever. Parallel to this, technological change and the emergence of new players bringing about innovative solutions are boosting the development of flexibility...... business models will play an important role in ensuring sufficiency and efficiency of flexibility services....

  16. Flexible lithium-ion planer thin-film battery

    KAUST Repository

    Kutbee, Arwa T.; Ghoneim, Mohamed T.; Hussain, Muhammad Mustafa

    2016-01-01

    Commercialization of wearable electronics requires miniaturized, flexible power sources. Lithium ion battery is a strong candidate as the next generation high performance flexible battery. The development of flexible materials for battery electrodes

  17. PTFE films with improved flexibility

    Science.gov (United States)

    Muraca, R. F.; Koch, A. A.

    1972-01-01

    Development and application of flexible polytetrafluroethylene films for expulsion bladders in spacecraft propellant tanks are described. Flexibility of material is obtained by reducing crystallinity through annealing and quenching in water. Physical and mechanical properties of material are presented.

  18. Consumer Central Energy Flexibility in Office Buildings

    DEFF Research Database (Denmark)

    Billanes, Joy Dalmacio; Ma, Zheng; Jørgensen, Bo Nørregaard

    2017-01-01

    Energy flexibility in buildings will play an important role in the smart energy system. Office buildings have more potentials to provide energy flexibility to the grid compared to other types of buildings, due to the existing building management, control systems and large energy consumption....... Consumers in office buildings (building owners/managers and occupants) take a main role for adopting and engaging in building energy flexibility. In this paper provides a systematic review of consumer central energy flexibility in office buildings with the discussion of social, technical and business...... can boost energy flexibility in the office buildings....

  19. Special Issue: Flexible Work Arrangements.

    Science.gov (United States)

    Olmstead, Barney, Ed.

    1996-01-01

    Section 1 contains five chapters on flexible work arrangements, self-employment, working from home, part-time professionals, job sharing, and temporary employment. Section 2 includes reviews of four books on working flexibly, concluding with a list of 23 additional readings. (SK)

  20. Flexible displays, rigid designs?

    DEFF Research Database (Denmark)

    Hornbæk, Kasper

    2015-01-01

    Rapid technological progress has enabled a wide range of flexible displays for computing devices, but the user experience--which we're only beginning to understand--will be the key driver for successful designs.......Rapid technological progress has enabled a wide range of flexible displays for computing devices, but the user experience--which we're only beginning to understand--will be the key driver for successful designs....

  1. Flexible lithium-ion planer thin-film battery

    KAUST Repository

    Kutbee, Arwa T.

    2016-02-03

    Commercialization of wearable electronics requires miniaturized, flexible power sources. Lithium ion battery is a strong candidate as the next generation high performance flexible battery. The development of flexible materials for battery electrodes suffers from the limited material choices. In this work, we present a flexible inorganic lithium-ion battery with no restrictions on the materials used. The battery showed an enhanced normalized capacity of 146 ??Ah/cm2.

  2. Fast and anisotropic flexibility-rigidity index for protein flexibility and fluctuation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Opron, Kristopher [Department of Biochemistry and Molecular Biology, Michigan State University, Michigan 48824 (United States); Xia, Kelin [Department of Mathematics, Michigan State University, Michigan 48824 (United States); Wei, Guo-Wei, E-mail: wei@math.msu.edu [Department of Biochemistry and Molecular Biology, Michigan State University, Michigan 48824 (United States); Department of Mathematics, Michigan State University, Michigan 48824 (United States); Department of Electrical and Computer Engineering, Michigan State University, Michigan 48824 (United States)

    2014-06-21

    Protein structural fluctuation, typically measured by Debye-Waller factors, or B-factors, is a manifestation of protein flexibility, which strongly correlates to protein function. The flexibility-rigidity index (FRI) is a newly proposed method for the construction of atomic rigidity functions required in the theory of continuum elasticity with atomic rigidity, which is a new multiscale formalism for describing excessively large biomolecular systems. The FRI method analyzes protein rigidity and flexibility and is capable of predicting protein B-factors without resorting to matrix diagonalization. A fundamental assumption used in the FRI is that protein structures are uniquely determined by various internal and external interactions, while the protein functions, such as stability and flexibility, are solely determined by the structure. As such, one can predict protein flexibility without resorting to the protein interaction Hamiltonian. Consequently, bypassing the matrix diagonalization, the original FRI has a computational complexity of O(N{sup 2}). This work introduces a fast FRI (fFRI) algorithm for the flexibility analysis of large macromolecules. The proposed fFRI further reduces the computational complexity to O(N). Additionally, we propose anisotropic FRI (aFRI) algorithms for the analysis of protein collective dynamics. The aFRI algorithms permit adaptive Hessian matrices, from a completely global 3N × 3N matrix to completely local 3 × 3 matrices. These 3 × 3 matrices, despite being calculated locally, also contain non-local correlation information. Eigenvectors obtained from the proposed aFRI algorithms are able to demonstrate collective motions. Moreover, we investigate the performance of FRI by employing four families of radial basis correlation functions. Both parameter optimized and parameter-free FRI methods are explored. Furthermore, we compare the accuracy and efficiency of FRI with some established approaches to flexibility analysis, namely

  3. Flexibility evaluation of multiechelon supply chains.

    Science.gov (United States)

    Almeida, João Flávio de Freitas; Conceição, Samuel Vieira; Pinto, Luiz Ricardo; de Camargo, Ricardo Saraiva; Júnior, Gilberto de Miranda

    2018-01-01

    Multiechelon supply chains are complex logistics systems that require flexibility and coordination at a tactical level to cope with environmental uncertainties in an efficient and effective manner. To cope with these challenges, mathematical programming models are developed to evaluate supply chain flexibility. However, under uncertainty, supply chain models become complex and the scope of flexibility analysis is generally reduced. This paper presents a unified approach that can evaluate the flexibility of a four-echelon supply chain via a robust stochastic programming model. The model simultaneously considers the plans of multiple business divisions such as marketing, logistics, manufacturing, and procurement, whose goals are often conflicting. A numerical example with deterministic parameters is presented to introduce the analysis, and then, the model stochastic parameters are considered to evaluate flexibility. The results of the analysis on supply, manufacturing, and distribution flexibility are presented. Tradeoff analysis of demand variability and service levels is also carried out. The proposed approach facilitates the adoption of different management styles, thus improving supply chain resilience. The model can be extended to contexts pertaining to supply chain disruptions; for example, the model can be used to explore operation strategies when subtle events disrupt supply, manufacturing, or distribution.

  4. Functional aspects of protein flexibility

    DEFF Research Database (Denmark)

    Teilum, Kaare; Olsen, Johan G; Kragelund, Birthe B

    2009-01-01

    this into an intuitive perception of protein function is challenging. Flexibility is of overwhelming importance for protein function, and the changes in protein structure during interactions with binding partners can be dramatic. The present review addresses protein flexibility, focusing on protein-ligand interactions...

  5. Skill Flexibility among Schoolteachers: Operationalization and Organizational Implications.

    Science.gov (United States)

    Rosenblatt, Zehava; Inbal, Batia

    1999-01-01

    Investigates effects of skill flexibility on Israeli secondary teachers' work attitudes and job performance. Both role and functional flexibility were associated with improved teachers' work performance; role flexibility is linked to high organizational commitment and low powerlessness. Principals appreciate skill flexibility, but organizational…

  6. Flexible labour strategy in the Dutch automotive industry

    NARCIS (Netherlands)

    van Riemsdijk, Maarten; de Leede, Jan

    2001-01-01

    Labour flexibility is a major way for companies to become more flexible. Why companies use flexible labour relations varies widely per industry. We assess the development of labour flexibility within the Dutch automotive industry. Four cases, together representing the production chain, are

  7. Endogenous price flexibility and optimal monetary policy

    OpenAIRE

    Ozge Senay; Alan Sutherland

    2014-01-01

    Much of the literature on optimal monetary policy uses models in which the degree of nominal price flexibility is exogenous. There are, however, good reasons to suppose that the degree of price flexibility adjusts endogenously to changes in monetary conditions. This article extends the standard new Keynesian model to incorporate an endogenous degree of price flexibility. The model shows that endogenizing the degree of price flexibility tends to shift optimal monetary policy towards complete i...

  8. ESF [Exploratory Shaft Facility] flexibility analysis

    International Nuclear Information System (INIS)

    Brusenback, R.W.

    1987-03-01

    This report directs that uncertainty allowances be included within the ESF facilities. The recommendations herein developed are intended as input to Title II Design criteria. Flexibility is measured first by lineal ft of drift, and then by hoisting rate and capacity of supporting utilities and services. A defined probability of need shows an extra 10,000 ft of drift for the first level of flexibility responding to testing and operations, and over 60,000 ft of drift for the second level of flexibility which recognizes possible need for perimeter drifting to investigate geologic stratigraphy. Observing there will be time constraints, a single shaft muck hoisting rate up to 170 to 250 tons per hour is recommended. The potential hoisting rate recommended for flexibility should be satisfied by a hoist approximately equivalent to, or conveniently upgraded from those being considered for sinking and construction, or 1000 horsepower. The cost of flexibility is limited to engineering planning and design (mostly conceptual) which makes later expansion achievable, and to selected items for initial construction where later upgrading would be impractical, impossible, or very costly. The cost is fixed to the level of flexibility and does not vary with excavated footage. The incremental margin is only a small fraction of the additional footage made available. Flexibility presents a strategy and not a position of design or technology. Examples used in this report are intended to be illustrative only, and not to lead design or cost estimates. 7 tabs

  9. Factors impeding flexible inpatient unit design.

    Science.gov (United States)

    Pati, Debajyoti; Evans, Jennie; Harvey, Thomas E; Bazuin, Doug

    2012-01-01

    To identify and examine factors extraneous to the design decision-making process that could impede the optimization of flexibility on inpatient units. A 2006 empirical study to identify domains of design decisions that affect flexibility on inpatient units found some indication in the context of the acuity-adaptable operational model that factors extraneous to the design process could have negatively influenced the successful implementation of the model. This raised questions regarding extraneous factors that might influence the successful optimization of flexibility. An exploratory, qualitative method was adopted to examine the question. Stakeholders from five recently built acute care inpatient units participated in the study, which involved three types of data collection: (1) verbal protocol data from a gaming session; (2) in-depth semi-structured interviews; and (3) shadowing frontline personnel. Data collection was conducted between June 2009 and November 2010. The study revealed at least nine factors extraneous to the design process that have the potential to hinder the optimization of flexibility in four domains: (1) systemic; (2) cultural; (3) human; and (4) financial. Flexibility is critical to hospital operations in the new healthcare climate, where cost reduction constitutes a vital target. From this perspective, flexibility and efficiency strategies can be influenced by (1) return on investment, (2) communication, (3) culture change, and (4) problem definition. Extraneous factors identified in this study could also affect flexibility in other care settings; therefore, these findings may be viewed from the overall context of hospital design.

  10. Financial Flexibility as a Phenomenon of Manifestation of Flexibility of the Financial System at the Micro-level

    Directory of Open Access Journals (Sweden)

    Laktionova Oleksandra A.

    2014-03-01

    Full Text Available The article considers financial flexibility of economic subjects in the context of specific features of manifestation of this property at the micro-level of the financial system. It generalises various theoretical approaches to understanding the essence of the financial flexibility in the context of motives of its formation, sources and instruments of realisation. It specifies criteria of financial flexibility: manoeuvrability, efficiency and economy. It studies interrelation between the financial flexibility and financial restrictions at the micro-level and, consequently, factors that determine them: capital market imperfection, development level and structure of the financial system, cyclicity of economy, and company characteristics (including financial architecture. The article describes their distinguishing features. It states that apart from maintaining the financial flexibility during formation of money reserves and debt load resource the companies can be guided by other motives. It offers classification of types of financial flexibility based on the sources and goals of formation, influence upon the financial potential, stages of reproduction of financial resources, the instruments used, engaged elements of the financial mechanism, stages of the business cycle and types of the used financial resources.

  11. Thin film thermocouples for in situ membrane electrode assembly temperature measurements in a polybenzimidazole-based high temperature proton exchange membrane unit cell

    DEFF Research Database (Denmark)

    Ali, Syed Talat; Lebæk, Jesper; Nielsen, Lars Pleth

    2010-01-01

    m thick layer of TFTCs on 75 mu m thick Kapton foil. The Kapton foil was treated with in situ argon plasma etching to improve the adhesion between TFTCs and the Kapton substrate. The TFTCs were covered with a 7 mu m liquid Kapton layer using spin coating technique to protect them from environmental......This paper presents Type-T thin film thermocouples (TFTCs) fabricated on Kapton (polyimide) substrate for measuring the internal temperature of PBI(polybenzimidazole)-based high temperature proton exchange membrane fuel cell (HT-PEMFC). Magnetron sputtering technique was employed to deposit a 2 mu...... degradation. This Kapton foil with deposited TFTCs was used as sealing inside a PBI (polybenzimidazole)-based single cell test rig, which enabled measurements of in situ temperature variations of the working fuel cell MEA. The performance of the TFTCs was promising with minimal interference to the operation...

  12. Climate Change

    Indian Academy of Sciences (India)

    Director

    2017-06-04

    Jun 4, 2017 ... Such earthquakes have significant social and economic impacts. ... reservoirs have been reported from about 120 sites through out the world during .... processes. ➢ Microbial networks ... Passive Accelerometer. Thermistor(s).

  13. Flexible learning and the design of instruction

    NARCIS (Netherlands)

    Collis, Betty; Nikolova, Iliana

    1998-01-01

    The paper deals with the problem of designing flexible learning and instruction. Flexibility is considered both from the learner's and the designer's perspective. The potential of telematics in the design, development and implementation of flexible and distance learning is discussed. A Method for

  14. Measuring and Comparing Energy Flexibilities

    DEFF Research Database (Denmark)

    Valsomatzis, Emmanouil; Hose, Katja; Pedersen, Torben Bach

    2015-01-01

    induced by time and amount individually, and by their com- bination. To this end, we introduce several flexibility measures that take into account the combined effect of time and energy on flex-offer flexibility and discuss their respective pros and cons through a number of realistic examples....

  15. Flexibility evaluation of multiechelon supply chains.

    Directory of Open Access Journals (Sweden)

    João Flávio de Freitas Almeida

    Full Text Available Multiechelon supply chains are complex logistics systems that require flexibility and coordination at a tactical level to cope with environmental uncertainties in an efficient and effective manner. To cope with these challenges, mathematical programming models are developed to evaluate supply chain flexibility. However, under uncertainty, supply chain models become complex and the scope of flexibility analysis is generally reduced. This paper presents a unified approach that can evaluate the flexibility of a four-echelon supply chain via a robust stochastic programming model. The model simultaneously considers the plans of multiple business divisions such as marketing, logistics, manufacturing, and procurement, whose goals are often conflicting. A numerical example with deterministic parameters is presented to introduce the analysis, and then, the model stochastic parameters are considered to evaluate flexibility. The results of the analysis on supply, manufacturing, and distribution flexibility are presented. Tradeoff analysis of demand variability and service levels is also carried out. The proposed approach facilitates the adoption of different management styles, thus improving supply chain resilience. The model can be extended to contexts pertaining to supply chain disruptions; for example, the model can be used to explore operation strategies when subtle events disrupt supply, manufacturing, or distribution.

  16. Flexible Thermoelectric Generators on Silicon Fabric

    KAUST Repository

    Sevilla, Galo T.

    2012-11-01

    In this work, the development of a Thermoelectric Generator on Flexible Silicon Fabric is explored to extend silicon electronics for flexible platforms. Low cost, easily deployable plastic based flexible electronics are of great interest for smart textile, wearable electronics and many other exciting applications. However, low thermal budget processing and fundamentally limited electron mobility hinders its potential to be competitive with well established and highly developed silicon technology. The use of silicon in flexible electronics involve expensive and abrasive materials and processes. In this work, high performance flexible thermoelectric energy harvesters are demonstrated from low cost bulk silicon (100) wafers. The fabrication of the micro- harvesters was done using existing silicon processes on silicon (100) and then peeled them off from the original substrate leaving it for reuse. Peeled off silicon has 3.6% thickness of bulk silicon reducing the thermal loss significantly and generating nearly 30% more output power than unpeeled harvesters. The demonstrated generic batch processing shows a pragmatic way of peeling off a whole silicon circuitry after conventional fabrication on bulk silicon wafers for extremely deformable high performance integrated electronics. In summary, by using a novel, low cost process, this work has successfully integrated existing and highly developed fabrication techniques to introduce a flexible energy harvester for sustainable applications.

  17. Flexible and rigid cystoscopy in women.

    Science.gov (United States)

    Gee, Jason R; Waterman, Bradley J; Jarrard, David F; Hedican, Sean P; Bruskewitz, Reginald C; Nakada, Stephen Y

    2009-01-01

    Previous studies have evaluated the tolerability of rigid versus flexible cystoscopy in men. Similar studies, however, have not been performed in women. We sought to determine whether office-based flexible cystoscopy was better tolerated than rigid cystoscopy in women. Following full IRB approval, women were prospectively randomized in a single-blind manner. Patients were randomized to flexible or rigid cystoscopy and draped in the lithotomy position to maintain blinding of the study. Questionnaires evaluated discomfort before, during, and after cystoscopy. Thirty-six women were randomized to flexible (18) or rigid (18) cystoscopy. Indications were surveillance (16), hematuria (15), recurrent UTIs (2), voiding dysfunction (1), and other (2). All questionnaires were returned by 31/36 women. Using a 10-point visual analog scale (VAS), median discomfort during the procedure for flexible and rigid cystoscopy were 1.4 and 1.8, respectively, in patients perceiving pain. Median recalled pain 1 week later was similar at 0.8 and 1.15, respectively. None of these differences were statistically significant. Flexible and rigid cystoscopy are well tolerated in women. Discomfort during and after the procedure is minimal in both groups. Urologists should perform either procedure in women based on their preference and skill level.

  18. Flexible magnetic thin films and devices

    Science.gov (United States)

    Sheng, Ping; Wang, Baomin; Li, Runwei

    2018-01-01

    Flexible electronic devices are highly attractive for a variety of applications such as flexible circuit boards, solar cells, paper-like displays, and sensitive skin, due to their stretchable, biocompatible, light-weight, portable, and low cost properties. Due to magnetic devices being important parts of electronic devices, it is essential to study the magnetic properties of magnetic thin films and devices fabricated on flexible substrates. In this review, we mainly introduce the recent progress in flexible magnetic thin films and devices, including the study on the stress-dependent magnetic properties of magnetic thin films and devices, and controlling the properties of flexible magnetic films by stress-related multi-fields, and the design and fabrication of flexible magnetic devices. Project supported by the National Key R&D Program of China (No. 2016YFA0201102), the National Natural Science Foundation of China (Nos. 51571208, 51301191, 51525103, 11274321, 11474295, 51401230), the Youth Innovation Promotion Association of the Chinese Academy of Sciences (No. 2016270), the Key Research Program of the Chinese Academy of Sciences (No. KJZD-EW-M05), the Ningbo Major Project for Science and Technology (No. 2014B11011), the Ningbo Science and Technology Innovation Team (No. 2015B11001), and the Ningbo Natural Science Foundation (No. 2015A610110).

  19. Analysis of a Thrust Bearing with Flexible Pads and Flexible Supports

    DEFF Research Database (Denmark)

    Klit, Peder; Thomsen, Kim

    2007-01-01

    A theoretical analysis of a hydrodynamic thrust bearing is presented. The bearing investigated is used in an ndustrial product. The lubricant is water, but the results are valid also for other lubricants.At first the results from a 1-dimensional model for the fluid film forces and the associated...... deformation of the bearing geometry is presented. This model enlightens the influence of pad flexibility and support location and flexibility. Subsequently results from a 2-dimensional model of the bearing is presented. The model is used to carry out an optimization of the bearing design, and the obtained...

  20. Flexible Transparent Supercapacitors Based on Hierarchical Nanocomposite Films.

    Science.gov (United States)

    Chen, Fanhong; Wan, Pengbo; Xu, Haijun; Sun, Xiaoming

    2017-05-31

    Flexible transparent electronic devices have recently gained immense popularity in smart wearable electronics and touch screen devices, which accelerates the development of the portable power sources with reliable flexibility, robust transparency and integration to couple these electronic devices. For potentially coupled as energy storage modules in various flexible, transparent and portable electronics, the flexible transparent supercapacitors are developed and assembled from hierarchical nanocomposite films of reduced graphene oxide (rGO) and aligned polyaniline (PANI) nanoarrays upon their synergistic advantages. The nanocomposite films are fabricated from in situ PANI nanoarrays preparation in a blended solution of aniline monomers and rGO onto the flexible, transparent, and stably conducting film (FTCF) substrate, which is obtained by coating silver nanowires (Ag NWs) layer with Meyer rod and then coating of rGO layer on polyethylene terephthalate (PET) substrate. Optimization of the transparency, the specific capacitance, and the flexibility resulted in the obtained all-solid state nanocomposite supercapacitors exhibiting enhanced capacitance performance, good cycling stability, excellent flexibility, and superior transparency. It provides promising application prospects for exploiting flexible, low-cost, transparent, and high-performance energy storage devices to be coupled into various flexible, transparent, and wearable electronic devices.

  1. Ground temperatures in ice-cemented ground at Linnaeus Terrace, Dry Valleys, Antarctica, Version 1

    Data.gov (United States)

    National Aeronautics and Space Administration — Soil temperatures were measured with Campbell 107 soil thermistors. Thermistors were placed at 0, 17, 23 (just above the ice-cemented permafrost) and 40 cm depth. To...

  2. The Flexibility Scale: Development and Preliminary Validation of a Cognitive Flexibility Measure in Children with Autism Spectrum Disorders

    Science.gov (United States)

    Strang, John F.; Anthony, Laura G.; Yerys, Benjamin E.; Hardy, Kristina K.; Wallace, Gregory L.; Armour, Anna C.; Dudley, Katerina; Kenworthy, Lauren

    2017-01-01

    Flexibility is a key component of executive function, and is related to everyday functioning and adult outcomes. However, existing informant reports do not densely sample cognitive aspects of flexibility; the Flexibility Scale (FS) was developed to address this gap. This study investigates the validity of the FS in 221 youth with ASD and 57…

  3. Considerations of device and operational flexibility in FER

    International Nuclear Information System (INIS)

    Sugihara, Masayoshi; Miki, Nobuharu; Nishio, Satoshi; Yamada, Masao; Yamamoto, Shin

    1988-01-01

    Expected physics uncertainties in DT burning plasma of FER, which may not be removed completely at the start of construction or DT operation, are reviewed. Several possible device and operational flexibility scenarios to cope with these uncertainties are considered. They are (1) Plasma size enlargement scenario, (2) Plasma shape flexibility scenario, (3) Heating/Current drive/Control system flexibility scenario, (4) Impurity control system flexibility scenario and (5) Advanced operation scenario. Feasibility of these flexibility scenarios are examined and shown to be practicable. However, careful assessment of the physics data base is necessary at the start of construction and DT operation to proceed to actually implement these flexibilities in FER. (author)

  4. High-flexibility, noncollapsing lightweight hose

    Science.gov (United States)

    Williams, D.A.

    1993-04-20

    A high-flexibility, noncollapsing, lightweight, large-bore, wire-reinforced hose is inside fiber-reinforced PVC tubing that is flexible, lightweight, and abrasion resistant. It provides a strong, kink- and collapse-free conduit for moving large quantities of dangerous fluids, e.g., removing radioactive waste water or processing chemicals.

  5. Acquisition of Mechanically Assisted Spark Plasma Sintering System for Advanced Research and Education on Functionally Graded Hybrid Materials

    Science.gov (United States)

    2012-03-14

    Institute. The proposed effort offers a multidisciplinary research program to achieve the topic goals by coupling thermal- acoustic - mechanical flight...optional optical pyrometer .  Single port for standard (mechanical vacuum pump) and high vacuum system. POWER SUPPLY  10,000 amp, 10 VDC pulsed...Amperage TEMPERATURE CONTROL SYSTEM  Ten (10) Type K and five (5) Type C thermocouples with protective flexible sheaths.  Optical Pyrometer

  6. 49 CFR 178.940 - Standards for flexible Large Packagings.

    Science.gov (United States)

    2010-10-01

    .... Flexible Large Packagings types are designated: (1) 51H flexible plastics. (2) 51M flexible paper. (b... this subchapter, flexible Large Packaging must be resistant to aging and degradation caused by ultraviolet radiation. (5) For plastic flexible Large Packagings, if necessary, protection against ultraviolet...

  7. Flexible energy-storage devices: design consideration and recent progress.

    Science.gov (United States)

    Wang, Xianfu; Lu, Xihong; Liu, Bin; Chen, Di; Tong, Yexiang; Shen, Guozhen

    2014-07-23

    Flexible energy-storage devices are attracting increasing attention as they show unique promising advantages, such as flexibility, shape diversity, light weight, and so on; these properties enable applications in portable, flexible, and even wearable electronic devices, including soft electronic products, roll-up displays, and wearable devices. Consequently, considerable effort has been made in recent years to fulfill the requirements of future flexible energy-storage devices, and much progress has been witnessed. This review describes the most recent advances in flexible energy-storage devices, including flexible lithium-ion batteries and flexible supercapacitors. The latest successful examples in flexible lithium-ion batteries and their technological innovations and challenges are reviewed first. This is followed by a detailed overview of the recent progress in flexible supercapacitors based on carbon materials and a number of composites and flexible micro-supercapacitors. Some of the latest achievements regarding interesting integrated energy-storage systems are also reviewed. Further research direction is also proposed to surpass existing technological bottle-necks and realize idealized flexible energy-storage devices. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Flexible licensing

    Directory of Open Access Journals (Sweden)

    Martyn Jansen

    2012-07-01

    Full Text Available The case is presented for a more flexible approach to licensing online library resources. Today's distributed education environment creates pressure for UK higher and further education institutions (HEI/FEIs to form partnerships and to develop educational products and roll them out across the globe. Online library resources are a key component of distributed education and yet existing licensing agreements struggle to keep pace with the increasing range of users and purposes for which they are required. This article describes the process of developing a flexible approach to licensing and proposes a new model licence for online library resources which has the adaptability needed in this new global educational landscape. These ideas have been presented and discussed at various workshops across Eduserv's and JISC Collections' higher education and publisher communities, and further consultation is ongoing.

  9. Flexible Working Time Arrangements in Bulgaria

    OpenAIRE

    Beleva, Iskra

    2009-01-01

    The objective of this paper is to analyze the flexible working time arrangements in Bulgaria, using a life-course perspective. Two important features have to be outlined, namely: underdeveloped flexible forms of employment in the country, including working time arrangement, and lack of previous analysis on flexible working time arrangements from the angle of life-course perspective. The author describes the regulatory framework, collective agreements at national and company level as a frame w...

  10. Sensor Technologies on Flexible Substrates

    Science.gov (United States)

    Koehne, Jessica

    2016-01-01

    NASA Ames has developed sensor technologies on flexible substrates integrated into textiles for personalized environment monitoring and human performance evaluation. Current technologies include chemical sensing for gas leak and event monitoring and biological sensors for human health and performance monitoring. Targeted integration include next generation EVA suits and flexible habitats.

  11. Cellulose Nanofiber Composite Substrates for Flexible Electronics

    Science.gov (United States)

    Ronald Sabo; Jung-Hun Seo; Zhenqiang Ma

    2012-01-01

    Flexible electronics have a large number of potential applications including malleable displays and wearable computers. The current research into high-speed, flexible electronic substrates employs the use of plastics for the flexible substrate, but these plastics typically have drawbacks, such as high thermal expansion coefficients. Transparent films made from...

  12. Flexible Pedagogies: Employer Engagement and Work-Based Learning. Flexible Pedagogies: Preparing for the Future Series

    Science.gov (United States)

    Kettle, Jane

    2013-01-01

    This publication focuses on national and international policy initiatives to develop a better understanding of work-based learners and the types of flexibility that may well enhance their study especially pedagogically. As part of our five-strand research project "Flexible Pedagogies: preparing for the future" it: (1) highlights the…

  13. Bio-Inspired Flexible Cellular Actuating Systems

    Science.gov (United States)

    2013-11-21

    S. Hong, “Robust adaptive boundary control of a flexible marine riser with vessel dynamics,” Automatica, vol. 47, pp. 722–732, 2011. [22] D. H...conditionally accepted. [6] W. He, S. S. Ge, B. V. E. How, Y. S. Choo, and K. S. Hong, “Robust adaptive boundary control of a flexible marine riser ... flexible robotic actuators, often represented by a distributed parameter system or a partial differential equation. We establish a model-guided

  14. Flexible benefit plans in Dutch organisations

    OpenAIRE

    Hillebrink, C.

    2006-01-01

    Flexible benefit plans give employees a greater say over the composition of their benefits than traditional Dutch benefit plans. These arrangements developed in a time of further individualisation, increasing flexibility in the workplace, and a tight labour market in the Netherlands. By giving employees a choice in the way they are paid, employers hoped to become more attractive employers, and lend a helping hand to employees who were combining work and care. In this study, flexible benefit p...

  15. Flexible Work Options within the Organisational System

    Science.gov (United States)

    Albion, Majella J.; Chee, Munli

    2006-01-01

    The availability of flexible work options provides an opportunity for individuals to shape their careers in order to optimise their work and life goals. This study takes a systems theory approach to examine how the use of flexible work options influences relationships and interactions in the workplace. The "Flexible Work Options…

  16. Limited access: gender, occupational composition, and flexible work scheduling.

    Science.gov (United States)

    Glauber, Rebecca

    2011-01-01

    The current study draws on national data to explore differences in access to flexible work scheduling by the gender composition of women's and men's occupations. Results show that those who work in integrated occupations are more likely to have access to flexible scheduling. Women and men do not take jobs with lower pay in return for greater access to flexibility. Instead, jobs with higher pay offer greater flexibility. Integrated occupations tend to offer the greatest access to flexible scheduling because of their structural locations. Part-time work is negatively associated with men's access to flexible scheduling but positively associated with women's access. Women have greater flexibility when they work for large establishments, whereas men have greater flexibility when they work for small establishments.

  17. Education, Training and the Flexible Labour Market.

    Science.gov (United States)

    Merson, Martin

    1996-01-01

    The British government's policy of flexible labor market may be interpreted as either flexibility of conditions, which encourages temporary, contingent work, or flexibility of skills, a repertoire that enables workers to undertake a range of tasks as needed. The challenge for educators is to help workers understand and engage in an uncertain world…

  18. Labor Supply Flexibility and Portfolio Choice

    OpenAIRE

    Zvi Bodie; William Samuelson

    1989-01-01

    This paper develops a model showing that people who have flexibility in choosing how much to work will prefer to invest substantially more of their money in risky assets than if they had no such flexibility. Viewed in this way, labor supply flexibility offers insurance against adverse investment outcomes. The model provides support for the conventional wisdom that the young can tolerate more risk in their investment portfolios than the old. The model has other implications for the study of ho...

  19. Flexible spin-orbit torque devices

    Energy Technology Data Exchange (ETDEWEB)

    Lee, OukJae; You, Long; Jang, Jaewon; Subramanian, Vivek [Department of Electrical Engineering and Computer Sciences, University of California at Berkeley, Berkeley, California 94720 (United States); Salahuddin, Sayeef [Department of Electrical Engineering and Computer Sciences, University of California at Berkeley, Berkeley, California 94720 (United States); Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States)

    2015-12-21

    We report on state-of-the-art spintronic devices synthesized and fabricated directly on a flexible organic substrate. Large perpendicular magnetic anisotropy was achieved in ultrathin ferromagnetic heterostructures of Pt/Co/MgO sputtered on a non-rigid plastic substrate at room temperature. Subsequently, a full magnetic reversal of the Co was observed by exploiting the spin orbit coupling in Pt that leads to a spin accumulation at the Pt/Co interface when an in-plane current is applied. Quasi-static measurements show the potential for operating these devices at nano-second speeds. Importantly, the behavior of the devices remained unchanged under varying bending conditions (up to a bending radius of ≈ ±20–30 mm). Furthermore, the devices showed robust operation even after application of 10{sup 6} successive pulses, which is likely sufficient for many flexible applications. Thus, this work demonstrates the potential for integrating high performance spintronic devices on flexible substrates, which could lead to many applications ranging from flexible non-volatile magnetic memory to local magnetic resonance imaging.

  20. Flexible spin-orbit torque devices

    International Nuclear Information System (INIS)

    Lee, OukJae; You, Long; Jang, Jaewon; Subramanian, Vivek; Salahuddin, Sayeef

    2015-01-01

    We report on state-of-the-art spintronic devices synthesized and fabricated directly on a flexible organic substrate. Large perpendicular magnetic anisotropy was achieved in ultrathin ferromagnetic heterostructures of Pt/Co/MgO sputtered on a non-rigid plastic substrate at room temperature. Subsequently, a full magnetic reversal of the Co was observed by exploiting the spin orbit coupling in Pt that leads to a spin accumulation at the Pt/Co interface when an in-plane current is applied. Quasi-static measurements show the potential for operating these devices at nano-second speeds. Importantly, the behavior of the devices remained unchanged under varying bending conditions (up to a bending radius of ≈ ±20–30 mm). Furthermore, the devices showed robust operation even after application of 10 6 successive pulses, which is likely sufficient for many flexible applications. Thus, this work demonstrates the potential for integrating high performance spintronic devices on flexible substrates, which could lead to many applications ranging from flexible non-volatile magnetic memory to local magnetic resonance imaging

  1. Can flexibility help you float?

    Science.gov (United States)

    Burton, L. J.; Bush, J. W. M.

    2012-10-01

    We consider the role of flexibility in the weight-bearing characteristics of bodies floating at an interface. Specifically, we develop a theoretical model for a two-dimensional thin floating plate that yields the maximum stable plate load and optimal stiffness for weight support. Plates small relative to the capillary length are primarily supported by surface tension, and their weight-bearing potential does not benefit from flexibility. Above a critical size comparable to the capillary length, flexibility assists interfacial flotation. For plates on the order of and larger than the capillary length, deflection from an initially flat shape increases the force resulting from hydrostatic pressure, allowing the plate to support a greater load. In this large plate limit, the shape that bears the most weight is a semicircle, which displaces the most fluid above the plate for a fixed plate length. Exact results for maximum weight-bearing plate shapes are compared to analytic approximations made in the limits of large and small plate sizes. The value of flexibility for floating to a number of biological organisms is discussed in light of our study.

  2. Flexible wings in flapping flight

    Science.gov (United States)

    Moret, Lionel; Thiria, Benjamin; Zhang, Jun

    2007-11-01

    We study the effect of passive pitching and flexible deflection of wings on the forward flapping flight. The wings are flapped vertically in water and are allowed to move freely horizontally. The forward speed is chosen by the flapping wing itself by balance of drag and thrust. We show, that by allowing the wing to passively pitch or by adding a flexible extension at its trailing edge, the forward speed is significantly increased. Detailed measurements of wing deflection and passive pitching, together with flow visualization, are used to explain our observations. The advantage of having a wing with finite rigidity/flexibility is discussed as we compare the current results with our biological inspirations such as birds and fish.

  3. Two dimensional nanomaterials for flexible supercapacitors.

    Science.gov (United States)

    Peng, Xu; Peng, Lele; Wu, Changzheng; Xie, Yi

    2014-05-21

    Flexible supercapacitors, as one of most promising emerging energy storage devices, are of great interest owing to their high power density with great mechanical compliance, making them very suitable as power back-ups for future stretchable electronics. Two-dimensional (2D) nanomaterials, including the quasi-2D graphene and inorganic graphene-like materials (IGMs), have been greatly explored to providing huge potential for the development of flexible supercapacitors with higher electrochemical performance. This review article is devoted to recent progresses in engineering 2D nanomaterials for flexible supercapacitors, which survey the evolution of electrode materials, recent developments in 2D nanomaterials and their hybrid nanostructures with regulated electrical properties, and the new planar configurations of flexible supercapacitors. Furthermore, a brief discussion on future directions, challenges and opportunities in this fascinating area is also provided.

  4. Flexible nanoscale high-performance FinFETs

    KAUST Repository

    Sevilla, Galo T.

    2014-10-28

    With the emergence of the Internet of Things (IoT), flexible high-performance nanoscale electronics are more desired. At the moment, FinFET is the most advanced transistor architecture used in the state-of-the-art microprocessors. Therefore, we show a soft-etch based substrate thinning process to transform silicon-on-insulator (SOI) based nanoscale FinFET into flexible FinFET and then conduct comprehensive electrical characterization under various bending conditions to understand its electrical performance. Our study shows that back-etch based substrate thinning process is gentler than traditional abrasive back-grinding process; it can attain ultraflexibility and the electrical characteristics of the flexible nanoscale FinFET show no performance degradation compared to its rigid bulk counterpart indicating its readiness to be used for flexible high-performance electronics.

  5. Flexibility-enabling Contracts in Electricity Markets

    DEFF Research Database (Denmark)

    Boscan, Luis; Poudineh, Rahmatallah

    As the share of intermittent renewable energy increases in the generation mix, power systems are exposed to greater levels of uncertainty and risk, which requires planners, policy and business decision makers to incentivise flexibility, that is: their adaptability to unforeseen variations....... Additionally, along with traditional sources, which already enable flexibility, a number of business models, such as thermostat-based demand response, aggregators and small storage providers, are emerging in electricity markets and expected to constitute important sources of flexibility in future decentralised...... power systems. However, due to presence of high transaction costs, relative to the size of resource, the emerging small resources cannot directly participate in an organised electricity market and/or compete. This paper asks the fundamental question of how should the provision of flexibility, as a multi...

  6. Testing of the coping flexibility hypothesis based on the dual-process theory: Relationships between coping flexibility and depressive Symptoms.

    Science.gov (United States)

    Kato, Tsukasa

    2015-12-15

    According to the dual-process theory of coping flexibility (Kato, 2012), coping flexibility is the ability to discontinue an ineffective coping strategy (i.e., evaluation coping process) and implement an alternative strategy (i.e., adaptive coping process). The coping flexibility hypothesis (CFH) proposes that the ability to engage in flexible coping is related to better psychological functioning and physical health, including less depression. I the present study, participants were 393 American Whites, 429 Australian Whites, and 496 Chinese, selected from the data pool of the 2013 Coping and Health Survey (see Kato, 2014b). They completed both the Coping Flexibility Scale (Kato, 2012), which is based on the dual-process theory of coping flexibility, and the Center for Epidemiologic Studies Depression Scale (CES-D). For all nationalities and genders, evaluation coping and adaptive coping were significantly correlated with lower levels of depressive symptoms. Structural equation modeling revealed that evaluation coping was associated with lower depressive symptoms for all nationalities and genders, whereas no significant relationships between adaptive coping and depressive symptoms were found for any nationalities. Our results partially supported that the CFH fits with the dual-process theory of coping flexibility. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  7. Movable MEMS Devices on Flexible Silicon

    KAUST Repository

    Ahmed, Sally

    2013-01-01

    Flexible electronics have gained great attention recently. Applications such as flexible displays, artificial skin and health monitoring devices are a few examples of this technology. Looking closely at the components of these devices, although MEMS

  8. Workplace flexibility.

    Science.gov (United States)

    Scordato, C; Harris, J

    1990-01-01

    Whether your organization is in a growth pattern or downsizing, you are probably facing change. To gain some insight into your options, here is an in-depth look at the problems and benefits of some flexible work arrangements from a just published study by Catalyst.

  9. Flexibility conflict?

    NARCIS (Netherlands)

    Delsen, L.W.M.; Bauer, F.; Groß, H.; Sieglen, G.

    2002-01-01

    The chapter deals with the presupposed conflict of interests between employers and employees resulting from a decoupling of operating hours and working times. It starts from the notion that both long operating hours and flexibility are relative concepts. As there is some discretion, the ultimate

  10. Natural flexible dermal armor.

    Science.gov (United States)

    Yang, Wen; Chen, Irene H; Gludovatz, Bernd; Zimmermann, Elizabeth A; Ritchie, Robert O; Meyers, Marc A

    2013-01-04

    Fish, reptiles, and mammals can possess flexible dermal armor for protection. Here we seek to find the means by which Nature derives its protection by examining the scales from several fish (Atractosteus spatula, Arapaima gigas, Polypterus senegalus, Morone saxatilis, Cyprinius carpio), and osteoderms from armadillos, alligators, and leatherback turtles. Dermal armor has clearly been developed by convergent evolution in these different species. In general, it has a hierarchical structure with collagen fibers joining more rigid units (scales or osteoderms), thereby increasing flexibility without significantly sacrificing strength, in contrast to rigid monolithic mineral composites. These dermal structures are also multifunctional, with hydrodynamic drag (in fish), coloration for camouflage or intraspecies recognition, temperature and fluid regulation being other important functions. The understanding of such flexible dermal armor is important as it may provide a basis for new synthetic, yet bioinspired, armor materials. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Soldier Flexible Personal Digital Assistant Program

    National Research Council Canada - National Science Library

    Price, Mark; Woytowich, Jason; Carlson, Marc

    2008-01-01

    The main goal of the Soldier Flexible Personal Digital Assistant Program was to develop prototypes of a novel flexible display technology device for demonstration in a laboratory setting and use in Future Force Warrior (FFW) demonstrations...

  12. Simulation analysis of resource flexibility on healthcare processes.

    Science.gov (United States)

    Simwita, Yusta W; Helgheim, Berit I

    2016-01-01

    This paper uses discrete event simulation to explore the best resource flexibility scenario and examine the effect of implementing resource flexibility on different stages of patient treatment process. Specifically we investigate the effect of resource flexibility on patient waiting time and throughput in an orthopedic care process. We further seek to explore on how implementation of resource flexibility on patient treatment processes affects patient access to healthcare services. We focus on two resources, namely, orthopedic surgeon and operating room. The observational approach was used to collect process data. The developed model was validated by comparing the simulation output with actual patient data collected from the studied orthopedic care process. We developed different scenarios to identify the best resource flexibility scenario and explore the effect of resource flexibility on patient waiting time, throughput, and future changes in demand. The developed scenarios focused on creating flexibility on service capacity of this care process by altering the amount of additional human resource capacity at different stages of patient care process and extending the use of operating room capacity. The study found that resource flexibility can improve responsiveness to patient demand in the treatment process. Testing different scenarios showed that the introduction of resource flexibility reduces patient waiting time and improves throughput. The simulation results show that patient access to health services can be improved by implementing resource flexibility at different stages of the patient treatment process. This study contributes to the current health care literature by explaining how implementing resource flexibility at different stages of patient care processes can improve ability to respond to increasing patients demands. This study was limited to a single patient process; studies focusing on additional processes are recommended.

  13. On the concept of flexibility: A dual control perspective

    NARCIS (Netherlands)

    A.C.J. de Leeuw (A. C J); H.W. Volberda (Henk)

    1996-01-01

    textabstractOrganizational flexibility has recently received much attention from researchers, management consultants and practitioners. In general, the term 'flexibility' has a positive connotation: flexible organizations are the better ones. However, the meaning of flexibility as well as its

  14. Tunnel flexibility effect on the ground surface acceleration response

    Science.gov (United States)

    Baziar, Mohammad Hassan; Moghadam, Masoud Rabeti; Choo, Yun Wook; Kim, Dong-Soo

    2016-09-01

    Flexibility of underground structures relative to the surrounding medium, referred to as the flexibility ratio, is an important factor that influences their dynamic interaction. This study investigates the flexibility effect of a box-shaped subway tunnel, resting directly on bedrock, on the ground surface acceleration response using a numerical model verified against dynamic centrifuge test results. A comparison of the ground surface acceleration response for tunnel models with different flexibility ratios revealed that the tunnels with different flexibility ratios influence the acceleration response at the ground surface in different ways. Tunnels with lower flexibility ratios have higher acceleration responses at short periods, whereas tunnels with higher flexibility ratios have higher acceleration responses at longer periods. The effect of the flexibility ratio on ground surface acceleration is more prominent in the high range of frequencies. Furthermore, as the flexibility ratio of the tunnel system increases, the acceleration response moves away from the free field response and shifts towards the longer periods. Therefore, the flexibility ratio of the underground tunnels influences the peak ground acceleration (PGA) at the ground surface, and may need to be considered in the seismic zonation of urban areas.

  15. IEA EBC Annex 67 Energy Flexible Buildings

    DEFF Research Database (Denmark)

    Marszal, Anna Joanna; Jensen, Søren Østergaard

    2016-01-01

    know ledge on and demonstration of the Energy Flexibility Buildings can provide for the energy grids as well of to identify critical aspects and possible solutions to manage this Energy Flexibility. The paper discusses the background, the aims and the work plan of IEA (International Energy Agency) EBC......The foreseen large deployment of renewable energy sources may seriously affect the stability of energy grids. It will be necessary to control energy consumption to match instantaneous energy production. The built-in Energy Flexibility in buildings may be utilized for stabilizing the energy grids......, allowing for a larger roll out of renewable technologies. The Energy Flexibility of a building is the ability to manage its energy demand and generation according to local climate conditions, user needs and grid requirements. Energy Flexibility of buildings will thus allow for demand side management...

  16. Fabrication of conducting composite sheets using cost-effective graphite flakes and amorphous styrene acrylonitrile for enhanced thermistor, dielectric, and electromagnetic interference shielding properties

    Energy Technology Data Exchange (ETDEWEB)

    Panwar, Varij, E-mail: varijpanwarcertain@gmail.com [Electronics and Communication Engineering, Graphic Era University, Dehradun, Uttarakhand (India); Gill, Fateh Singh; Rathi, Vikas; Tewari, V.K. [Electronics and Communication Engineering, Graphic Era University, Dehradun, Uttarakhand (India); Mehra, R.M. [Sharda University, Greater Noida (India); Park, Jong-Oh, E-mail: jop@jnu.ac.kr [School of Mechanical Engineering, Chonnam National University, Gwangju (Korea, Republic of); Park, Sukho, E-mail: shpark12@dgist.ac.kr [Department of Robotics Engineering, Daegu Gyeongbuk Institute of Science and Technology, Daegu (Korea, Republic of)

    2017-06-01

    The fabrication of strong conducting composite sheets (CCSs) using a simple technique with cost-effective materials is desirable for capacitor, decoupling capacitor, and electromagnetic interference (EMI) shielding applications. Here, we used cost-effective graphite flakes (GFs) as a conducting filler and amorphous poly (styrene-co-acrylonitrile) (PSAN) as an insulating polymer to fabricate a CCS via a simple mechanical mixing and hot compression molding process in 2.5 h, with the aim to save time and avoid the use of toxic reagents, which are generally used in chemical methods. In the present method, the GFs are connected in diffusively adhere polymer matrix, controlled by temperature and pressure that generate the conduction in the CCSs. The resulting PSAN/GF CCSs were characterized by using scanning electron microscopy (SEM), differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), and hardness tests. The GFs penetrated the interfacial region of PSAN, thus improving the thermistor and dielectric properties (dielectric constant, AC conductivity, and dissipation factor) of the PSAN/GF CCSs. Furthermore, the PSAN/GF CCSs showed enhanced hardness and EMI shielding effectiveness (SE) properties in the X-band frequency range (8.5–12.5 GHz). The percolation theory was implemented to DC and AC conductivity. To detect the transition of the dielectric properties, the dielectric constant of the CCSs was analyzed with increasing volume fraction of GFs in the radio frequency region. The improved dielectric constant, AC conductivity, and dissipation factor of the PSAN/GF CCS, indicated a significant improvement in their EMI shielding properties in the X-band frequency range, which were measured using the waveguide method. The ac conductivity of PSAN/GF CCS shows stable behavior in the higher frequency ranges. The EMISE of PSAN/GF CCS were found to increase with increasing GF content due to the absorbance mechanism. - Highlights: • Enhanced hardness and

  17. Research into Flexibility Services. Final Report

    International Nuclear Information System (INIS)

    2005-03-01

    The Dutch Office for Energy Regulation (DTe) is currently investigating the Dutch gas flexibility market. DTe is concerned that Gasunie is dominant in the market. In order to take a view of Gasunie's market position, DTe needs to first define the market for gas flexibility services and then explore whether Gasunie is dominant in the market (or markets). DTe has commissioned Frontier to undertake the respective formal analysis. This report summarises the findings by Frontier. On the basis of this report and a formal consultation process, We follow a three-step approach to the study: (1) We first define the relevant markets for gas flexibility (Section 3); (2) We then analyse the structure of the markets for flexibility that we have defined (Section 4); (3) Finally, we assess whether Gasunie is dominant in the relevant markets, taking account of market shares and other competitive effects (Section 5). This document is the Final Report, which contains our views as to the market definition for gas flexibility and the position of Gasunie in the market. The remainder of this document is set out as follows: Section 2 provides an overview of aspects of the Dutch gas industry relevant to this study; Section 3 sets out our approach to defining the market and de-Mops our conclusions on the markets for gas flexibility; Section 4 provides our view as to the structure of the relevant flexibility markets as defined in Section 3; Section 5 reports our assessment as to whether Gasunie is dominant in the relevant markets, taking account of market shares and other competitive effects; Section 6 sets out our conclusions about the competitive assessment. We include three annexes that set out details related to the market definition and analysis of dominance

  18. Production Flexibility and Hedging

    Directory of Open Access Journals (Sweden)

    Georges Dionne

    2015-12-01

    Full Text Available We extend the analysis on hedging with price and output uncertainty by endogenizing the output decision. Specifically, we consider the joint determination of output and hedging in the case of flexibility in production. We show that the risk-averse firm always maintains a short position in the futures market when the futures price is actuarially fair. Moreover, in the context of an example, we show that the presence of production flexibility reduces the incentive to hedge for all risk averse agents.

  19. On the concept of flexibility : A dual control perspective

    NARCIS (Netherlands)

    de Leeuw, A.C.J.; Volberda, H.W.

    Organizational flexibility has recently received much attention from researchers, management consultants and practitioners, In general, the term 'flexibility' has a positive connotation: flexible organizations are the better ones. However, the meaning of flexibility as well as its relation to the

  20. How flexible is flexible? Accounting for the effect of rescheduling possibilities in choice of departure time for work trips

    DEFF Research Database (Denmark)

    Thorhauge, Mikkel; Cherchi, Elisabetta; Rich, Jeppe

    2016-01-01

    for each of these activities. We then built a stated preference experiment to infer preferences on departure time choice, and estimated a mixed logit model, based on the scheduling model, to account for the effects of daily activity schedules and their constraints. Our results show that measuring......In departure time studies it is crucial to ascertain whether or not individuals are flexible in their choices. Previous studies have found that individuals with flexible work times have a lower value of time for late arrivals. Flexibility is usually measured in terms of flexible work start time...... is not accounted for....

  1. Balancing energy flexibilities through aggregation

    DEFF Research Database (Denmark)

    Valsomatzis, Emmanouil; Hose, Katja; Pedersen, Torben Bach

    2014-01-01

    One of the main goals of recent developments in the Smart Grid area is to increase the use of renewable energy sources. These sources are characterized by energy fluctuations that might lead to energy imbalances and congestions in the electricity grid. Exploiting inherent flexibilities, which exist...... in both energy production and consumption, is the key to solving these problems. Flexibilities can be expressed as flex-offers, which due to their high number need to be aggregated to reduce the complexity of energy scheduling. In this paper, we discuss balance aggregation techniques that already during...... aggregation aim at balancing flexibilities in production and consumption to reduce the probability of congestions and reduce the complexity of scheduling. We present results of our extensive experiments....

  2. Hydrodynamics of a flexible plate between pitching rigid plates

    Science.gov (United States)

    Kim, Junyoung; Kim, Daegyoum

    2017-11-01

    The dynamics of a flexible plate have been studied as a model problem in swimming and flying of animals and fluid-structure interaction of plants and flags. Motivated by fish schooling and an array of sea grasses, we investigate the dynamics of a flexible plate closely placed between two pitching rigid plates. In most studies on passive deformation of the flexible plate, the plate is immersed in a uniform flow or a wavy flow. However, in this study, the flexible plate experiences periodic deformation by the oscillatory flow generated by the prescribed pitching motion of the rigid plates. In our model, the pitching axes of the rigid plates and the clamping position of the flexible plate are aligned on the same line. The flexible plate shows various responses depending on length and pitching frequency of rigid plates, thickness of a flexible plate, and free-stream velocity. To find the effect of each variable on the response of the flexible plate, amplitude of a trailing edge and modal contribution of a flapping motion are compared, and flow structure around the flexible plate is examined.

  3. On the concept of flexibility: A dual control perspective

    OpenAIRE

    Leeuw, A. C J; Volberda, Henk

    1996-01-01

    textabstractOrganizational flexibility has recently received much attention from researchers, management consultants and practitioners. In general, the term 'flexibility' has a positive connotation: flexible organizations are the better ones. However, the meaning of flexibility as well as its relation to the functioning of an organization is still ambiguous. This article develops a systematic and multidimensional picture of flexibility on the basis of views taken from the systems theory of co...

  4. Wearable and flexible electronics for continuous molecular monitoring.

    Science.gov (United States)

    Yang, Yiran; Gao, Wei

    2018-04-03

    Wearable biosensors have received tremendous attention over the past decade owing to their great potential in predictive analytics and treatment toward personalized medicine. Flexible electronics could serve as an ideal platform for personalized wearable devices because of their unique properties such as light weight, low cost, high flexibility and great conformability. Unlike most reported flexible sensors that mainly track physical activities and vital signs, the new generation of wearable and flexible chemical sensors enables real-time, continuous and fast detection of accessible biomarkers from the human body, and allows for the collection of large-scale information about the individual's dynamic health status at the molecular level. In this article, we review and highlight recent advances in wearable and flexible sensors toward continuous and non-invasive molecular analysis in sweat, tears, saliva, interstitial fluid, blood, wound exudate as well as exhaled breath. The flexible platforms, sensing mechanisms, and device and system configurations employed for continuous monitoring are summarized. We also discuss the key challenges and opportunities of the wearable and flexible chemical sensors that lie ahead.

  5. Flexibility, but for whom? : A new approach to examining labour market flexibility across Europe using company level data

    OpenAIRE

    Chung, Heejung

    2006-01-01

    Labour market flexibility continues to be one of the key issues in the reform of labour markets in welfare states. The way in which various countries adapt to this need differs according to their institutions and prevailing strategies. Despite the vast numbers of studies addressing this issue, labour market flexibility has been examined predominantly by concentrating on the arrangements that firms adopt to adjust to market fluctuations. Thus flexibility arrangements are perceived to exist onl...

  6. Flexible Working and Couples' Coordination of Time Schedules

    OpenAIRE

    Bryan, Mark L.; Sevilla Sanz, Almudena

    2014-01-01

    Using previously unexploited data on time scheduling in the employment and household contexts, we investigate the effect of flexible working on couples' coordination of their daily work time schedules in the UK. We consider three distinct dimensions of flexible working: flexibility of daily start and finish times (flexitime), flexibility of work times over the year (annualised hours), and generalised control of working hours. We find that in couples with flexitime there is greater spouse sync...

  7. Lumbopelvic flexibility modulates neuromuscular responses during trunk flexion-extension.

    Science.gov (United States)

    Sánchez-Zuriaga, Daniel; Artacho-Pérez, Carla; Biviá-Roig, Gemma

    2016-06-01

    Various stimuli such as the flexibility of lumbopelvic structures influence the neuromuscular responses of the trunk musculature, leading to different load sharing strategies and reflex muscle responses from the afferents of lumbopelvic mechanoreceptors. This link between flexibility and neuromuscular response has been poorly studied. The aim of this study was to investigate the relationship between lumbopelvic flexibility and neuromuscular responses of the erector spinae, hamstring and abdominal muscles during trunk flexion-extension. Lumbopelvic movement patterns were measured in 29 healthy women, who were separated into two groups according to their flexibility during trunk flexion-extension. The electromyographic responses of erector spinae, rectus abdominis and biceps femoris were also recorded. Subjects with greater lumbar flexibility had significantly less pelvic flexibility and vice versa. Subjects with greater pelvic flexibility had a higher rate of relaxation and lower levels of hamstring activation during maximal trunk flexion. The neuromuscular response patterns of the hamstrings seem partially modulated by pelvic flexibility. Not so with the lumbar erector spinae and lumbar flexibility, despite the assertions of some previous studies. The results of this study improve our knowledge of the relationships between trunk joint flexibility and neuromuscular responses, a relationship which may play a role in low back pain. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Labour flexibility in China's companies: An Empirical Study

    NARCIS (Netherlands)

    Y. Chen (Yongping)

    2001-01-01

    textabstractLabour flexibility in China???s Companies: An Empirical Study explores labour flexibility at the workplace in ten manufacturing companies in China. It addresses how HRM contributes and facilitates management in coping with increasing market competition. Flexible labour practices are

  9. Behavioral flexibility and problem solving in an invasive bird.

    Science.gov (United States)

    Logan, Corina J

    2016-01-01

    Behavioral flexibility is considered an important trait for adapting to environmental change, but it is unclear what it is, how it works, and whether it is a problem solving ability. I investigated behavioral flexibility and problem solving experimentally in great-tailed grackles, an invasive bird species and thus a likely candidate for possessing behavioral flexibility. Grackles demonstrated behavioral flexibility in two contexts, the Aesop's Fable paradigm and a color association test. Contrary to predictions, behavioral flexibility did not correlate across contexts. Four out of 6 grackles exhibited efficient problem solving abilities, but problem solving efficiency did not appear to be directly linked with behavioral flexibility. Problem solving speed also did not significantly correlate with reversal learning scores, indicating that faster learners were not the most flexible. These results reveal how little we know about behavioral flexibility, and provide an immense opportunity for future research to explore how individuals and species can use behavior to react to changing environments.

  10. Flexible benefit plans in Dutch organisations

    NARCIS (Netherlands)

    Hillebrink, C.

    2006-01-01

    Flexible benefit plans give employees a greater say over the composition of their benefits than traditional Dutch benefit plans. These arrangements developed in a time of further individualisation, increasing flexibility in the workplace, and a tight labour market in the Netherlands. By giving

  11. 77 FR 8082 - Regulatory Flexibility Agenda

    Science.gov (United States)

    2012-02-13

    ... Required: Yes. Agency Contact: Alicia Goldin, Division of Trading and Markets, Securities and Exchange.../01/11 Regulatory Flexibility Analysis Required: Yes. Agency Contact: Alicia Goldin, Division of... Withdrawn 10/01/11 Regulatory Flexibility Analysis Required: Yes. Agency Contact: Alicia Goldin, Division of...

  12. Flexible cryogenic conduit

    International Nuclear Information System (INIS)

    Brindza, P.D.; Wines, R.R.; Takacs, J.J.

    1999-01-01

    A flexible and relatively low cost cryogenic conduit is described. The flexible cryogenic conduit of the present invention comprises a first inner corrugated tube with single braided serving, a second outer corrugated tube with single braided serving concentric with the inner corrugated tube, and arranged outwardly about the periphery of the inner corrugated tube and between the inner and outer corrugated tubes: a superinsulation layer; a one half lap layer of polyester ribbon; a one half lap layer of copper ribbon; a spirally wound refrigeration tube; a second one half lap layer of copper ribbon; a second one half lap layer of polyester ribbon; a second superinsulation layer; a third one half lap layer of polyester ribbon; and a spirally wound stretchable and compressible filament

  13. Carbon Nanotube Flexible and Stretchable Electronics.

    Science.gov (United States)

    Cai, Le; Wang, Chuan

    2015-12-01

    The low-cost and large-area manufacturing of flexible and stretchable electronics using printing processes could radically change people's perspectives on electronics and substantially expand the spectrum of potential applications. Examples range from personalized wearable electronics to large-area smart wallpapers and from interactive bio-inspired robots to implantable health/medical apparatus. Owing to its one-dimensional structure and superior electrical property, carbon nanotube is one of the most promising material platforms for flexible and stretchable electronics. Here in this paper, we review the recent progress in this field. Applications of single-wall carbon nanotube networks as channel semiconductor in flexible thin-film transistors and integrated circuits, as stretchable conductors in various sensors, and as channel material in stretchable transistors will be discussed. Lastly, state-of-the-art advancement on printing process, which is ideal for large-scale fabrication of flexible and stretchable electronics, will also be reviewed in detail.

  14. Workplace flexibility across the lifespan

    OpenAIRE

    Bal, Pieter; Jansen, Paul G W

    2016-01-01

    As demographic changes impact the workplace, governments, organizations and workers arelooking for ways to sustain optimal working lives at higher ages. Workplace flexibility has beenintroduced as a potential way workers can have more satisfying working lives until theirretirement ages. This paper presents a critical review of the literature on workplace flexibilityacross the lifespan. It discusses how flexibility has been conceptualized across differentdisciplines, and postulates a definitio...

  15. Development of a fuel-rod simulator and small-diameter thermocouples for high-temperature, high-heat-flux tests in the Gas-Cooled Fast Reactor Core Flow Test Loop

    International Nuclear Information System (INIS)

    McCulloch, R.W.; MacPherson, R.E.

    1983-03-01

    The Core Flow Test Loop was constructed to perform many of the safety, core design, and mechanical interaction tests in support of the Gas-Cooled Fast Reactor (GCFR) using electrically heated fuel rod simulators (FRSs). Operation includes many off-normal or postulated accident sequences including transient, high-power, and high-temperature operation. The FRS was developed to survive: (1) hundreds of hours of operation at 200 W/cm 2 , 1000 0 C cladding temperature, and (2) 40 h at 40 W/cm 2 , 1200 0 C cladding temperature. Six 0.5-mm type K sheathed thermocouples were placed inside the FRS cladding to measure steady-state and transient temperatures through clad melting at 1370 0 C

  16. Flexible Training's Intrusion on Work/Life Balance

    Directory of Open Access Journals (Sweden)

    Zane BERGE

    2005-04-01

    Full Text Available Flexible Training's Intrusion on Work/Life Balance Seema TAKIYAJennifer ARCHBOLDZane BERGEBaltimore, USA Learning interventions should be aligned with the human learning system. To be effective, they have to support human learning, not work against it. Thalheimer, 2004 ABSTRACT With more companies allowing “flextime”, more access to elearning, and telecomuting, the line between workplace flexibility and work-life balance begins to blur. Companies “sell” to employees the flexibility of being able to complete training programs from the comfort of the participant's home, allowing them to learn at their own speed. In many ways, this solution is of great value to many employees. What also must be considered with the flexibility such training offers, is the unintentional consequences. This article explores questions such as does this flexibility create a 24-hour work day where the employee is continually accessible to work? Does it result in less family, personal and leisure time to the detriment of the worker?

  17. Wearable Flexible Sensors: A Review

    KAUST Repository

    Nag, Anindya

    2017-05-18

    The paper provides a review on some of the significant research work done on wearable flexible sensors (WFS). Sensors fabricated with flexible materials have been attached to a person along with the embedded system to monitor a parameter and transfer the significant data to the monitoring unit for further analyses. The use of wearable sensors has played a quite important role to monitor physiological parameters of a person to minimize any malfunctioning happening in the body. The paper categorizes the work according to the materials used for designing the system, the network protocols and different types of activities that were being monitored. The challenges faced by the current sensing systems and future opportunities for the wearable flexible sensors regarding its market values are also briefly explained in the paper.

  18. Wearable Flexible Sensors: A Review

    KAUST Repository

    Nag, Anindya; Mukhopadhyay, Subhas Chandra; Kosel, Jü rgen

    2017-01-01

    The paper provides a review on some of the significant research work done on wearable flexible sensors (WFS). Sensors fabricated with flexible materials have been attached to a person along with the embedded system to monitor a parameter and transfer the significant data to the monitoring unit for further analyses. The use of wearable sensors has played a quite important role to monitor physiological parameters of a person to minimize any malfunctioning happening in the body. The paper categorizes the work according to the materials used for designing the system, the network protocols and different types of activities that were being monitored. The challenges faced by the current sensing systems and future opportunities for the wearable flexible sensors regarding its market values are also briefly explained in the paper.

  19. Flexible Query Answering Systems 2006

    DEFF Research Database (Denmark)

    -computer interaction. The overall theme of the FQAS conferences is innovative query systems aimed at providing easy, flexible, and intuitive access to information. Such systems are intended to facilitate retrieval from information repositories such as databases, libraries, and the World-Wide Web. These repositories......This volume constitutes the proceedings of the Seventh International Conference on Flexible Query Answering Systems, FQAS 2006, held in Milan, Italy, on June 7--10, 2006. FQAS is the premier conference for researchers and practitioners concerned with the vital task of providing easy, flexible...... are typically equipped with standard query systems which are often inadequate, and the focus of FQAS is the development of query systems that are more expressive, informative, cooperative, and productive. These proceedings contain contributions from invited speakers and 53 original papers out of about 100...

  20. FLEXIBLE BUDGET OF SPORT COMPETITIONS

    Directory of Open Access Journals (Sweden)

    Dragan Vukasović

    2009-11-01

    Full Text Available Manager of sport competition has right to decide and also to take responsibility for costs, income and financial results. From economic point of wiev flexible budget and planning cost calculations is top management base for analyzing success level of sport competition. Flexible budget is made before sport competition with few output level, where one is always from static plan-master plan. At the end of competition when we have results, we make report of plan executing and we also analyzing plan variances. Results of comparation between achieved and planning level of static budget can be acceptable if achieved level is approximate to budget level or if we analyzing results from gross or net income. Flexible budget become very important in case of world eco- nomic crises

  1. Flexible Learning in an Information Society

    Science.gov (United States)

    Khan, Badrul, Ed.

    2007-01-01

    Flexible Learning in an Information Society uses a flexible learning framework to explain the best ways of creating a meaningful learning environment. This framework consists of eight factors--institutional, management, technological, pedagogical, ethical, interface design, resource support, and evaluation--and a systematic understanding of these…

  2. New business model of flexible housing

    NARCIS (Netherlands)

    Zairul, Z.; Geraedts, R.P.

    2015-01-01

    The Open Building (OB) and the concept of flexible housing has alwaysassociated with user’s ability to respond to changing demand. It is necessary that housing can adap to changing market conditions and different users’ requirements. Flexibility makes a crucial concept that one cannot ignore.

  3. Flexibility in 21st Century Power Systems

    Energy Technology Data Exchange (ETDEWEB)

    Cochran, J.; Miller, M.; Zinaman, O.; Milligan, M.; Arent, D.; Palmintier, B.; O' Malley, M.; Mueller, S.; Lannoye, E.; Tuohy, A.; Kujala, B.; Sommer, M.; Holttinen, H.; Kiviluoma, J.; Soonee, S. K.

    2014-05-01

    Flexibility of operation--the ability of a power system to respond to change in demand and supply--is a characteristic of all power systems. Flexibility is especially prized in twenty-first century power systems, with higher levels of grid-connected variable renewable energy (primarily, wind and solar). This paper summarizes the analytic frameworks that have emerged to measure this characteristic and distills key principles of flexibility for policy makers.

  4. A Novel Assessment of Flexibility by Microcirculatory Signals

    Directory of Open Access Journals (Sweden)

    Jian-Guo Bau

    2013-12-01

    Full Text Available Flexibility testing is one of the most important fitness assessments. It is generally evaluated by measuring the range of motion (RoM of body segments around a joint center. This study presents a novel assessment of flexibility in the microcirculatory aspect. Eighteen college students were recruited for the flexibility assessment. The flexibility of the leg was defined according to the angle of active ankle dorsiflexion measured by goniometry. Six legs were excluded, and the remaining thirty legs were categorized into two groups, group H (n = 15 with higher flexibility and group L (n = 15 with lower flexibility, according to their RoM. The microcirculatory signals of the gastrocnemius muscle on the belly were monitored by using Laser-Doppler Flowmetry (LDF with a noninvasive skin probe. Three indices of nonpulsatile component (DC, pulsatile component (AC and perfusion pulsatility (PP were defined from the LDF signals after signal processing. The results revealed that both the DC and AC values of the group H that demonstrated higher stability underwent muscle stretching. In contrast, these indices of group L had interferences and became unstable during muscle stretching. The PP value of group H was a little higher than that of group L. These primary findings help us to understand the microcirculatory physiology of flexibility, and warrant further investigations for use of non-invasive LDF techniques in the assessment of flexibility.

  5. Flexible automation and the loss of pooling synergy

    OpenAIRE

    Slomp, Jannes; Zee, Durk-Jouke van der

    2001-01-01

    This paper focuses on the effects of flexible automation on the performance of a job shop. Flexible automated machines may significantly improve the delivery performance and the flow time of jobs. The insertion of a flexible automated system in a job shop, however, also has a counter effect on the manufacturing performance. This is caused by the reduction of pooling synergy due to the dedication implied by flexible automated machines. This paper investigates by means of a simulation study to ...

  6. Harnessing Flexibility from Hot and Cold

    DEFF Research Database (Denmark)

    Kiviluoma, Juha; Heinen, Steve; Qazi, Hassan

    2017-01-01

    As has been often reported, electricity systems with high levels of variable wind and solar power generation would benefit from demand flexibility. What is not as often mentioned is that electrification of the transport and heat sectors could exacerbate the need for flexibility, if they are imple...

  7. Flexible MgO Barrier Magnetic Tunnel Junctions.

    Science.gov (United States)

    Loong, Li Ming; Lee, Wonho; Qiu, Xuepeng; Yang, Ping; Kawai, Hiroyo; Saeys, Mark; Ahn, Jong-Hyun; Yang, Hyunsoo

    2016-07-01

    Flexible MgO barrier magnetic tunnel junction (MTJ) devices are fabricated using a transfer printing process. The flexible MTJ devices yield significantly enhanced tunneling magnetoresistance of ≈300% and improved abruptness of switching, as residual strain in the MTJ structure is released during the transfer process. This approach could be useful for flexible electronic systems that require high-performance memory components. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Flexibility at Work: A Study of Further Education.

    Science.gov (United States)

    Edwards, Richard; Clarke, Julia; Harrison, Roger; Reeve, Fiona

    2001-01-01

    Interviews with 50 further education managers, lecturers, and students in Britain identified complex ways in which flexibility is experienced: (1) lecturers feel increasingly busy trying to provide flexibility; (2) role boundaries are becoming more and more fuzzy in the flexible workplace; and (3) there are notions of "good" and…

  9. Mandatory or Flexible: Whither Retirement Age Policy? | Ibiwoye ...

    African Journals Online (AJOL)

    ... to flexible retirement. It also found that flexible policy will have a positive welfare effect as many employees can then take care of their extended span of dependants for a longer period and employee productivity will also be improved. Key words: Retirement, Mandatory, Flexible, Pension Plan, Extended Family System.

  10. A Clearinghouse Concept for Distribution-Level Flexibility Services

    DEFF Research Database (Denmark)

    Heussen, Kai; Bondy, Daniel Esteban Morales; Hu, Junjie

    2013-01-01

    Flexibility resources on the demand side are anticipated to become a valuable asset for balancing renewable energy fluctuation as well as for reducing investment needs in distribution grids. To harvest this flexibility for distribution grids, flexibility services need to be defined that can...... be integrated with distribution grid operation and that provide a benefit that can be traded off against other grid investments. Two key challenges are here that the identification of useful services is still ongoing and that the transaction cost for the individually small contributions from the demand side...... could be prohibitive. This paper introduces a flexibility clearinghouse (FLECH) concept and isolates FLECH key functionality: to facilitate flexibility services in distribution grids by streamlining the relevant business interactions while keeping technical specifications open....

  11. Load and Flexibility Models for Distribution Grid Management

    DEFF Research Database (Denmark)

    Kouzelis, Konstantinos

    to advanced metering and control infrastructure investments. These investments will transform distribution networks into smarter" grids which will facilitate flexible load/generation control in return for financial and reliability benefits to electricity consumers. The theoretical idea of modernising the grid...... involve lack of generic load forecasts, need for flexible load/generation estimation techniques from smart meter measurements, deficiencies in online load distribution observability, and, finally, energy market compatible control algorithms which treat consumer flexibility in a fair manner. These modules...... congestions, is proposed. In the first step, a central controller manages flexibility proactively, whereas in the second step a decentralised control scheme deals with flexibility reactively. Both controllers are designed in such a way, that compatibility with contemporary markets is assured, while special...

  12. Supply chain integration, risk management and manufacturing flexibility

    DEFF Research Database (Denmark)

    Chaudhuri, Atanu; Boer, Harry; Taran, Yariv

    2018-01-01

    , respectively, and manufacturing flexibility. Design/methodology/approach – Using hierarchical regression, data are analyzed from a sample of 343 manufacturing plants in Asia collected in 2013-2014 as part of the International Manufacturing Strategy Survey (IMSS VI). Findings – Internal integration and supply......Purpose – The purpose of this paper is to investigate the impact of internal integration, external integration and supply chain risk management on manufacturing flexibility, and the moderating effect of supply chain risk management on the relationships between internal and external integration...... chain risk management have a direct effect on manufacturing flexibility. Supply chain risk management moderates the relationship between external integration and flexibility. Research limitations/implications – Further research is needed to generalize beyond the flexibility performance of discrete...

  13. Design of micro, flexible light-emitting diode arrays and fabrication of flexible electrodes

    International Nuclear Information System (INIS)

    Gao, Dan; Wang, Weibiao; Liang, Zhongzhu; Liang, Jingqiu; Qin, Yuxin; Lv, Jinguang

    2016-01-01

    In this study, we design micro, flexible light-emitting diode (LED) array devices. Using theoretical calculations and finite element simulations, we analyze the deformation of the conventional single electrode bar. Through structure optimization, we obtain a three-dimensional (3D), chain-shaped electrode structure, which has a greater bending degree. The optimized electrodes not only have a bigger bend but can also be made to spin. When the supporting body is made of polydimethylsiloxane (PDMS), the maximum bending degree of the micro, flexible LED arrays (4  ×  1 arrays) was approximately 230 µ m; this was obtained using the finite element method. The device (4  ×  1 arrays) can stretch to 15%. This paper describes the fabrication of micro, flexible LED arrays using microelectromechancial (MEMS) technology combined with electroplating technology. Specifically, the isolated grooves are made by dry etching which can isolate and protect the light-emitting units. A combination of MEMS technology and wet etching is used to fabricate the large size spacing. (paper)

  14. The flexibility of flexicurity

    DEFF Research Database (Denmark)

    Jensen, Carsten Strøby

    2011-01-01

    by a special relation between flexibility, social security and active labour market policy, where a high level of social security is seen as a precondition for a labour market characterized by flexibility. In this article it is argued that the Danish labour market is characterized by having not just one model...... of flexicurity, but two. These two models cover different parts of the labour market and different segments of employees. The first model (the blue-collar flexicurity model) – the one that is often focused on in the literature – covers primarily skilled and unskilled workers on the labour market. The second...

  15. Understanding flexible and distributed software development processes

    OpenAIRE

    Agerfalk, Par J.; Fitzgerald, Brian

    2006-01-01

    peer-reviewed The minitrack on Flexible and Distributed Software Development Processes addresses two important and partially intertwined current themes in software development: process flexibility and globally distributed software development

  16. 47 CFR 1.774 - Pricing flexibility.

    Science.gov (United States)

    2010-10-01

    ... copies shall be served upon the Chief, Wireline Competition Bureau and the Chief, Pricing Policy Division... 47 Telecommunication 1 2010-10-01 2010-10-01 false Pricing flexibility. 1.774 Section 1.774..., and Reports Involving Common Carriers Tariffs § 1.774 Pricing flexibility. (a) Petitions. (1) A...

  17. Application of carbon nanotubes flexible strain sensor in smart textiles

    Directory of Open Access Journals (Sweden)

    Qiong CHENG

    2017-10-01

    Full Text Available Smart textiles have not only the necessary functions of daily wear, but also the intelligence. The focus of the current textile materials research is the selection of flexible material. For flexible materials, carbon material is one of the ideal materials for preparing flexible strain gauges. The application of flexible strain sensor prepared by carbon nanotubes as a flexible material in smart textiles is the research content. The research status of carbon nanotubes flexible strain sensor is introduced from the aspects of the structure, properties and application. The characteristics and functions of flexible strain gages prepared with carbon nanotube fibers and carbon nanotube films as flexible materials are discussed in terms of selection, preparation method, performance test and application. At the same time, the advantages and disadvantages of the flexible strain sensor of carbon nanotubes are reviewed from the aspects of preparation difficulty, production cost and practical application effect. High sensitivity with high strain will be a key research direction for carbon nanotube flexible strain sensors.

  18. 21 CFR 886.1390 - Flexible diagnostic Fresnel lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Flexible diagnostic Fresnel lens. 886.1390 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1390 Flexible diagnostic Fresnel lens. (a) Identification. A flexible diagnostic Fresnel lens is a device that is a very thin lens which has...

  19. Flexible automation and the loss of pooling synergy

    NARCIS (Netherlands)

    Slomp, Jannes; Zee, Durk-Jouke van der

    This paper focuses on the effects of flexible automation on the performance of a job shop. Flexible automated machines may significantly improve the delivery performance and the flow time of jobs. The insertion of a flexible automated system in a job shop, however, also has a counter effect on the

  20. Active vibration control of spatial flexible multibody systems

    International Nuclear Information System (INIS)

    Neto, Maria Augusta; Ambrósio, Jorge A. C.; Roseiro, Luis M.; Amaro, A.; Vasques, C. M. A.

    2013-01-01

    In this work a flexible multibody dynamics formulation of complex models including elastic components made of composite materials is extended to include piezoelectric sensors and actuators. The only limitation for the deformation of a structural member is that they must remain elastic and linear when described in a coordinate frame fixed to a material point or region of its domain. The flexible finite-element model of each flexible body is obtained referring the flexible body nodal coordinates to the body fixed frame and using a diagonalized mass description of the inertia in the mass matrix and on the gyroscopic force vector. The modal superposition technique is used to reduce the number of generalized coordinates to a reasonable dimension for complex shaped structural models of flexible bodies. The active vibration control of the flexible multibody components is implemented using an asymmetric collocated piezoelectric sensor/actuator pair. An electromechanically coupled model is taken into account to properly consider the surface-bonded piezoelectric transducers and their effects on the time and spatial response of the flexible multibody components. The electromechanical effects are introduced in the flexible multibody equations of motion by the use of beam and plate/shell elements, developed to this purpose. A comparative study between the classical control strategies, constant gain and amplitude velocity feedback, and optimal control strategy, linear quadratic regulator (LQR), is performed in order to investigate their effectiveness to suppress vibrations in structures with piezoelectric sensing and actuating patches.

  1. Active vibration control of spatial flexible multibody systems

    Energy Technology Data Exchange (ETDEWEB)

    Neto, Maria Augusta, E-mail: augusta.neto@dem.uc.pt [Universidade de Coimbra (Polo II), Departamento de Engenharia Mecanica, Faculdade de Ciencia e Tecnologia (Portugal); Ambrosio, Jorge A. C., E-mail: jorge@dem.ist.utl.pt [Instituto Superior Tecnico, Instituto de Engenharia Mecanica (Portugal); Roseiro, Luis M., E-mail: lroseiro@isec.pt [Instituto Superior de Engenharia de Coimbra, Departamento de Engenharia Mecanica (Portugal); Amaro, A., E-mail: ana.amaro@dem.uc.pt [Universidade de Coimbra (Polo II), Departamento de Engenharia Mecanica, Faculdade de Ciencia e Tecnologia (Portugal); Vasques, C. M. A., E-mail: cvasques@inegi.up.pt [Universidade do Porto, INEGI-Instituto de Engenharia Mecanica e Gestao Industrial (Portugal)

    2013-06-15

    In this work a flexible multibody dynamics formulation of complex models including elastic components made of composite materials is extended to include piezoelectric sensors and actuators. The only limitation for the deformation of a structural member is that they must remain elastic and linear when described in a coordinate frame fixed to a material point or region of its domain. The flexible finite-element model of each flexible body is obtained referring the flexible body nodal coordinates to the body fixed frame and using a diagonalized mass description of the inertia in the mass matrix and on the gyroscopic force vector. The modal superposition technique is used to reduce the number of generalized coordinates to a reasonable dimension for complex shaped structural models of flexible bodies. The active vibration control of the flexible multibody components is implemented using an asymmetric collocated piezoelectric sensor/actuator pair. An electromechanically coupled model is taken into account to properly consider the surface-bonded piezoelectric transducers and their effects on the time and spatial response of the flexible multibody components. The electromechanical effects are introduced in the flexible multibody equations of motion by the use of beam and plate/shell elements, developed to this purpose. A comparative study between the classical control strategies, constant gain and amplitude velocity feedback, and optimal control strategy, linear quadratic regulator (LQR), is performed in order to investigate their effectiveness to suppress vibrations in structures with piezoelectric sensing and actuating patches.

  2. Evaluating the Value of Flexibility in Energy Regulation Markets

    DEFF Research Database (Denmark)

    Neupane, Bijay; Pedersen, Torben Bach; Thiesson, Bo

    2015-01-01

    In this paper, we perform an econometric analysis on the benefits of introducing flexibility in the Danish/Nordic regulating power market. The paper investigates the relationships between market power prices and regulation volumes, in order to quantify the effects of flexibility on regulating power...... prices. Further, we analyze the benefit for various types of flexibility and market objectives, to detect the type of energy flexibility that maximizes the benefits. Results show that if 3.87% of total demand is flexible, market can reduce the regulation cost by 49% and the regulation volume by 29.4%....

  3. Central beta-adrenergic modulation of cognitive flexibility.

    Science.gov (United States)

    Beversdorf, David Q; White, Dawn M; Chever, Daquesha C; Hughes, John D; Bornstein, Robert A

    2002-12-20

    Situational stressors and anxiety impede performance on creativity tests requiring cognitive flexibility. Preliminary research revealed better performance on a task requiring cognitive flexibility, the anagram task, after propranolol (beta-adrenergic antagonist) than after ephedrine (beta-adrenergic agonist). However, propranolol and ephedrine have both peripheral and central beta-adrenergic effects. In order to determine whether noradrenergic modulation of cognitive flexibility is a centrally or peripherally mediated phenomenon, we compared the effects of propranolol (peripheral and central beta-blocker), nadolol (peripheral beta-blocker), and placebo on anagram task performance. Solution latency scores for each subject were compared across the drug conditions. Anagram solution latency scores after propranolol were significantly lower than after nadolol. This suggests a centrally mediated modulatory influence of the noradrenergic system on cognitive flexibility.

  4. Optimal reduction of flexible dynamic system

    International Nuclear Information System (INIS)

    Jankovic, J.

    1994-01-01

    Dynamic system reduction is basic procedure in various problems of active control synthesis of flexible structures. In this paper is presented direct method for system reduction by explicit extraction of modes included in reduced model form. Criterion for optimal system discrete approximation in synthesis reduced dynamic model is also presented. Subjected method of system decomposition is discussed in relation to the Schur method of solving matrix algebraic Riccati equation as condition for system reduction. By using exposed method procedure of flexible system reduction in addition with corresponding example is presented. Shown procedure is powerful in problems of active control synthesis of flexible system vibrations

  5. Determinants of flexible work arrangements

    OpenAIRE

    Sarbu, Miruna

    2014-01-01

    Flexible work arrangements such as allowing employees to work at home are used in firms, especially since information and communication technologies have become so widespread. Using individual-level data from 10,884 German employees, this paper analyses the determinants of working at home as a form of flexible work arrangements. The analysis is based on descriptive analyses and a discrete choice model using a probit estimation approach. The results reveal that men have a higher...

  6. Organizing for Flexibility: Addressing Dynamic Capabilities and Organization Design

    OpenAIRE

    van der Weerdt, Niels; Volberda, Henk; Verwaal, Ernst; Stienstra, Marten

    2014-01-01

    The increasingly dynamic nature of organizational environments has led the research community to study organizational flexibility. Although the research literature stresses the complexity of the organizational flexibility construct, it lacks a comprehensive empirical study addressing the relationships among various dimensions of organizational flexibility. This chapter develops a theoretical framework specifying the linkages between types of flexibility and organization design characteristics...

  7. Nature-Inspired Structural Materials for Flexible Electronic Devices.

    Science.gov (United States)

    Liu, Yaqing; He, Ke; Chen, Geng; Leow, Wan Ru; Chen, Xiaodong

    2017-10-25

    Exciting advancements have been made in the field of flexible electronic devices in the last two decades and will certainly lead to a revolution in peoples' lives in the future. However, because of the poor sustainability of the active materials in complex stress environments, new requirements have been adopted for the construction of flexible devices. Thus, hierarchical architectures in natural materials, which have developed various environment-adapted structures and materials through natural selection, can serve as guides to solve the limitations of materials and engineering techniques. This review covers the smart designs of structural materials inspired by natural materials and their utility in the construction of flexible devices. First, we summarize structural materials that accommodate mechanical deformations, which is the fundamental requirement for flexible devices to work properly in complex environments. Second, we discuss the functionalities of flexible devices induced by nature-inspired structural materials, including mechanical sensing, energy harvesting, physically interacting, and so on. Finally, we provide a perspective on newly developed structural materials and their potential applications in future flexible devices, as well as frontier strategies for biomimetic functions. These analyses and summaries are valuable for a systematic understanding of structural materials in electronic devices and will serve as inspirations for smart designs in flexible electronics.

  8. Highly porous ceramic oxide aerogels having improved flexibility

    Science.gov (United States)

    Meador, Mary Ann B. (Inventor); Nguyen, Baochau N. (Inventor); Guo, Haiquan (Inventor)

    2012-01-01

    Ceramic oxide aerogels having improved flexibility are disclosed. Preferred embodiments exhibit high modulus and other strength properties despite their improved flexibility. The gels may be polymer cross-linked via organic polymer chains to further improve strength properties, without substantially detracting from the improved flexibility. Methods of making such aerogels are also disclosed.

  9. 49 CFR 230.41 - Flexible staybolts with caps.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Flexible staybolts with caps. 230.41 Section 230... Appurtenances Staybolts § 230.41 Flexible staybolts with caps. (a) General. Flexible staybolts with caps shall have their caps removed during every 5th annual inspection for the purpose of inspecting the bolts for...

  10. Flexible Pedagogies: Part-Time Learners and Learning in Higher Education. Flexible Pedagogies: Preparing for the Future Series

    Science.gov (United States)

    McLinden, Michael

    2013-01-01

    This publication focuses on national and international policy initiatives to develop a better understanding of part-time learners and the types of flexibility that may enhance their study especially pedagogically. As part of our five-strand research project "Flexible Pedagogies: preparing for the future" it: (1) highlights the challenges…

  11. Flexible heat pipes with integrated bioinspired design

    Directory of Open Access Journals (Sweden)

    Chao Yang

    2015-02-01

    Full Text Available In this work we report the facile fabrication and performance evaluation of flexible heat pipes that have integrated bioinspired wick structures and flexible polyurethane polymer connector design between the copper condenser and evaporator. Inside the heat pipe, a bioinspired superhydrophilic strong-base-oxidized copper mesh with multi-scale micro/nano-structures was used as the wicking material and deionized water was selected as working fluid. Thermal resistances of the fabricated flexible heat pipes charged with different filling ratios were measured under thermal power inputs ranging from 2 W to 12 W while the device was bent at different angles. The fabricated heat pipes with a 30% filling ratio demonstrated a low thermal resistance less than 0.01 K/W. Compared with the vertically oriented straight heat pipes, bending from 30° up to 120° has negligible influence on the heat-transfer performance. Furthermore, repeated heating tests indicated that the fabricated flexible heat pipes have consistent and reliable heat-transfer performance, thus would have important applications for advanced thermal management in three dimensional and flexible electronic devices.

  12. Flexible graphene bio-nanosensor for lactate.

    Science.gov (United States)

    Labroo, Pratima; Cui, Yue

    2013-03-15

    The development of a flexible nanosensor for detecting lactate could expand opportunities for using graphene, both in fundamental studies for a variety of device platforms and in practical applications. Graphene is a delicate single-layer, two-dimensional network of carbon atoms with ultrasensitive sensing capabilities. Lactic acid is important for clinical analysis, sports medicine, and the food industry. Recently, wearable and flexible bioelectronics on plastics have attracted great interest for healthcare, sports and defense applications due to their advantages of being light-weight, bendable, or stretchable. Here, we demonstrate for the first time the development of a flexible graphene-based bio-nanosensor to detect lactate. Our results show that flexible lactate biosensors can be fabricated on a variety of plastic substrates. The sensor can detect lactate sensitively from 0.08 μM to 20 μM with a fast steady-state measuring time of 2s. The sensor can also detect lactate under different mechanical bending conditions, the sensor response decreased as the bending angle and number of bending repetitions increased. We anticipate that these results could open exciting opportunities for fundamental studies of flexible graphene bioelectronics by using other bioreceptors, as well as a variety of wearable, implantable, real-time, or on-site applications in fields ranging from clinical analysis to defense. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. The value of flexibility in power markets

    International Nuclear Information System (INIS)

    Goutte, Stephane; Vassilopoulos, Philippe

    2017-01-01

    In this paper we attempt to quantify the net revenues that can be captured by a flexible resource able to react to the short term price variations on the day-ahead and intra-day markets in Germany. We find that the difference between day-ahead and intra-day revenues for a flexible resource has been increasing (although the profitability has been decreasing on both markets). This difference is more pronounced once 15 mn price variations can be captured by a flexible resource. The net revenues from the local 15 mn auction (which is held 3 hours after the hourly 'coupled' day-ahead auction) are more than eight times higher than the day-ahead hourly auction but below the net revenues that can be captured with the high prices from the continuous market. The results of the backward-looking empirical estimations allow us to distinguish and quantify two components of flexibility: (1) the 'immediacy' value as we are approaching real-time and the urgency of the delivery increases (this value is revealed during the continuous intra-day process and is highly linked to the stochastic nature of power supply and demand (i.e. wind/solar forecasts, forced outages of thermal generation,...) forecast error risk), and (2) the 'flexibility' component as a resource can react to variations of shorter granularity (15 mn Vs 60 mn). We model and quantify the 'flexibility' component. (authors)

  14. Functional flexibility in wild bonobo vocal behaviour

    Directory of Open Access Journals (Sweden)

    Zanna Clay

    2015-08-01

    Full Text Available A shared principle in the evolution of language and the development of speech is the emergence of functional flexibility, the capacity of vocal signals to express a range of emotional states independently of context and biological function. Functional flexibility has recently been demonstrated in the vocalisations of pre-linguistic human infants, which has been contrasted to the functionally fixed vocal behaviour of non-human primates. Here, we revisited the presumed chasm in functional flexibility between human and non-human primate vocal behaviour, with a study on our closest living primate relatives, the bonobo (Pan paniscus. We found that wild bonobos use a specific call type (the “peep” across a range of contexts that cover the full valence range (positive-neutral-negative in much of their daily activities, including feeding, travel, rest, aggression, alarm, nesting and grooming. Peeps were produced in functionally flexible ways in some contexts, but not others. Crucially, calls did not vary acoustically between neutral and positive contexts, suggesting that recipients take pragmatic information into account to make inferences about call meaning. In comparison, peeps during negative contexts were acoustically distinct. Our data suggest that the capacity for functional flexibility has evolutionary roots that predate the evolution of human speech. We interpret this evidence as an example of an evolutionary early transition away from fixed vocal signalling towards functional flexibility.

  15. Roll-to-roll slot-die coating of 400 mm wide, flexible, transparent Ag nanowire films for flexible touch screen panels.

    Science.gov (United States)

    Kim, Dong-Ju; Shin, Hae-In; Ko, Eun-Hye; Kim, Ki-Hyun; Kim, Tae-Woong; Kim, Han-Ki

    2016-09-28

    We report fabrication of large area Ag nanowire (NW) film coated using a continuous roll-to-roll (RTR) slot die coater as a viable alternative to conventional ITO electrodes for cost-effective and large-area flexible touch screen panels (TSPs). By controlling the flow rate of shear-thinning Ag NW ink in the slot die, we fabricated Ag NW percolating network films with different sheet resistances (30-70 Ohm/square), optical transmittance values (89-90%), and haze (0.5-1%) percentages. Outer/inner bending, twisting, and rolling tests as well as dynamic fatigue tests demonstrated that the mechanical flexibility of the slot-die coated Ag NW films was superior to that of conventional ITO films. Using diamond-shape patterned Ag NW layer electrodes (50 Ohm/square, 90% optical transmittance), we fabricated 12-inch flexible film-film type and rigid glass-film-film type TSPs. Successful operation of flexible TSPs with Ag NW electrodes indicates that slot-die-coated large-area Ag NW films are promising low cost, high performance, and flexible transparent electrodes for cost-effective large-area flexible TSPs and can be substituted for ITO films, which have high sheet resistance and are brittle.

  16. Roll-to-roll slot-die coating of 400 mm wide, flexible, transparent Ag nanowire films for flexible touch screen panels

    Science.gov (United States)

    Kim, Dong-Ju; Shin, Hae-In; Ko, Eun-Hye; Kim, Ki-Hyun; Kim, Tae-Woong; Kim, Han-Ki

    2016-09-01

    We report fabrication of large area Ag nanowire (NW) film coated using a continuous roll-to-roll (RTR) slot die coater as a viable alternative to conventional ITO electrodes for cost-effective and large-area flexible touch screen panels (TSPs). By controlling the flow rate of shear-thinning Ag NW ink in the slot die, we fabricated Ag NW percolating network films with different sheet resistances (30-70 Ohm/square), optical transmittance values (89-90%), and haze (0.5-1%) percentages. Outer/inner bending, twisting, and rolling tests as well as dynamic fatigue tests demonstrated that the mechanical flexibility of the slot-die coated Ag NW films was superior to that of conventional ITO films. Using diamond-shape patterned Ag NW layer electrodes (50 Ohm/square, 90% optical transmittance), we fabricated 12-inch flexible film-film type and rigid glass-film-film type TSPs. Successful operation of flexible TSPs with Ag NW electrodes indicates that slot-die-coated large-area Ag NW films are promising low cost, high performance, and flexible transparent electrodes for cost-effective large-area flexible TSPs and can be substituted for ITO films, which have high sheet resistance and are brittle.

  17. Trunk Flexibility Improvement in Response to Powered Assisted Exercise

    Directory of Open Access Journals (Sweden)

    B.S. Bains

    2016-07-01

    Full Text Available Background study: Flexibility in human spine has always plays an important role in dexterity and seamless ambulatory activities. When optimum range is not maintained by the trunk column, due to lack of flexibility, the posture gets affected resulting in reduce trunk rotation flexibility and mobility hence loss of complete trunk rotation. Objective: The purpose of this study is to determine the effect of Shapemaster Power Assisted Exercise Equipment (SPAEE on trunk flexibility. Methodology: Twenty healthy individual ages between 40 to 60 years were randomly divided into control and exercise groups. Shapemaster exercise program performed two times per week for 5 weeks and 45 minutes per session. Before and after 10 sessions of Shapemaster exercise protocol, Seated trunk rotation test was used to measure trunk flexibility. Results: Repeated measurement ANOVA were used to analysis data between groups. The results of this study illustrated that after 10th sessions trunk flexibility significantly improved (F (1.0, 18 = 11.732, p < 0.003. Conclusion: In conclusion results were determined that SPAEE is safe and it did effectively enhance flexibility among individual healthy adults. Keyword: Shapemaster Power Assisted Exercise Equipment (SPAEE, Trunk Flexibility, Healthy individual

  18. Studies of a flexible heliac configuration

    International Nuclear Information System (INIS)

    Hender, T.C.; Cantrell, J.L.; Harris, J.H.

    1987-07-01

    This paper documents a detailed study of the Flexible Heliac configuration. The remarkable flexibility of this device - which allows variation of the rotational transform, shear, and magnetic well depth over a relatively wide range - is described. Engineering considerations of error fields, finite cross-section conductors, and plasma coil clearances are also discussed

  19. An overview of carbon materials for flexible electrochemical capacitors.

    Science.gov (United States)

    He, Yongmin; Chen, Wanjun; Gao, Caitian; Zhou, Jinyuan; Li, Xiaodong; Xie, Erqing

    2013-10-07

    Under the background of the quick development of lightweight, flexible, and wearable electronic devices in our society, a flexible and highly efficient energy management strategy is needed for their counterpart energy-storage systems. Among them, flexible electrochemical capacitors (ECs) have been considered as one of the most promising candidates because of their significant advantages in power and energy densities, and unique properties of being flexible, lightweight, low-cost, and environmentally friendly compared with current energy storage devices. In a common EC, carbon materials play an irreplaceable and principal role in its energy-storage performance. Up till now, most progress towards flexible ECs technologies has mostly benefited from the continuous development of carbon materials. As a result, in view of the dual remarkable highlights of ECs and carbon materials, a summary of recent research progress on carbon-based flexible EC electrode materials is presented in this review, including carbon fiber (CF, consisting of carbon microfiber-CMF and carbon nanofiber-CNF) networks, carbon nanotube (CNT) and graphene coatings, CNT and/or graphene papers (or films), and freestanding three-dimensional (3D) flexible carbon-based macroscopic architectures. Furthermore, some promising carbon materials for great potential applications in flexible ECs are introduced. Finally, the trends and challenges in the development of carbon-based electrode materials for flexible ECs and their smart applications are analyzed.

  20. Flexible Organic Electronics in Biology: Materials and Devices.

    Science.gov (United States)

    Liao, Caizhi; Zhang, Meng; Yao, Mei Yu; Hua, Tao; Li, Li; Yan, Feng

    2015-12-09

    At the convergence of organic electronics and biology, organic bioelectronics attracts great scientific interest. The potential applications of organic semiconductors to reversibly transmit biological signals or stimulate biological tissues inspires many research groups to explore the use of organic electronics in biological systems. Considering the surfaces of movable living tissues being arbitrarily curved at physiological environments, the flexibility of organic bioelectronic devices is of paramount importance in enabling stable and reliable performances by improving the contact and interaction of the devices with biological systems. Significant advances in flexible organic bio-electronics have been achieved in the areas of flexible organic thin film transistors (OTFTs), polymer electrodes, smart textiles, organic electrochemical ion pumps (OEIPs), ion bipolar junction transistors (IBJTs) and chemiresistors. This review will firstly discuss the materials used in flexible organic bioelectronics, which is followed by an overview on various types of flexible organic bioelectronic devices. The versatility of flexible organic bioelectronics promises a bright future for this emerging area. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Flexible working hours and well-being in Finland.

    Science.gov (United States)

    Kandolin, I; Härmä, M; Toivanen, M

    2001-12-01

    Flexibility of working hours became more prevalent in the 1990s in Finland. According to a representative survey on Finnish wage and salary earners (n = 1790) at the beginning of 2000, a great majority of male (76%) and female (65%) employees regularly worked overtime and/or had irregular working hours every month. These employees were flexible in meeting the needs of their companies/employers. Individual flexibility of working hours was far less common, only one third of male and female employees were able to regulate their working hours. A better balance between company-controlled and individual flexibility would, however, improve the well-being of employees. Employees working overtime without being allowed to regulate their working hours felt more symptoms of distress and had more conflicts in combining workplace and family roles than those who could individually determine their working hours flexibly. An investment in individually determined flexibility, for example by means of participatory planning, would improve the well-being of employees, and thus also improve the productivity of the organization.

  2. Global mapping of DNA conformational flexibility on Saccharomyces cerevisiae.

    Directory of Open Access Journals (Sweden)

    Giulia Menconi

    2015-04-01

    Full Text Available In this study we provide the first comprehensive map of DNA conformational flexibility in Saccharomyces cerevisiae complete genome. Flexibility plays a key role in DNA supercoiling and DNA/protein binding, regulating DNA transcription, replication or repair. Specific interest in flexibility analysis concerns its relationship with human genome instability. Enrichment in flexible sequences has been detected in unstable regions of human genome defined fragile sites, where genes map and carry frequent deletions and rearrangements in cancer. Flexible sequences have been suggested to be the determinants of fragile gene proneness to breakage; however, their actual role and properties remain elusive. Our in silico analysis carried out genome-wide via the StabFlex algorithm, shows the conserved presence of highly flexible regions in budding yeast genome as well as in genomes of other Saccharomyces sensu stricto species. Flexibile peaks in S. cerevisiae identify 175 ORFs mapping on their 3'UTR, a region affecting mRNA translation, localization and stability. (TAn repeats of different extension shape the central structure of peaks and co-localize with polyadenylation efficiency element (EE signals. ORFs with flexible peaks share common features. Transcripts are characterized by decreased half-life: this is considered peculiar of genes involved in regulatory systems with high turnover; consistently, their function affects biological processes such as cell cycle regulation or stress response. Our findings support the functional importance of flexibility peaks, suggesting that the flexible sequence may be derived by an expansion of canonical TAYRTA polyadenylation efficiency element. The flexible (TAn repeat amplification could be the outcome of an evolutionary neofunctionalization leading to a differential 3'-end processing and expression regulation in genes with peculiar function. Our study provides a new support to the functional role of flexibility in

  3. Global mapping of DNA conformational flexibility on Saccharomyces cerevisiae.

    Science.gov (United States)

    Menconi, Giulia; Bedini, Andrea; Barale, Roberto; Sbrana, Isabella

    2015-04-01

    In this study we provide the first comprehensive map of DNA conformational flexibility in Saccharomyces cerevisiae complete genome. Flexibility plays a key role in DNA supercoiling and DNA/protein binding, regulating DNA transcription, replication or repair. Specific interest in flexibility analysis concerns its relationship with human genome instability. Enrichment in flexible sequences has been detected in unstable regions of human genome defined fragile sites, where genes map and carry frequent deletions and rearrangements in cancer. Flexible sequences have been suggested to be the determinants of fragile gene proneness to breakage; however, their actual role and properties remain elusive. Our in silico analysis carried out genome-wide via the StabFlex algorithm, shows the conserved presence of highly flexible regions in budding yeast genome as well as in genomes of other Saccharomyces sensu stricto species. Flexibile peaks in S. cerevisiae identify 175 ORFs mapping on their 3'UTR, a region affecting mRNA translation, localization and stability. (TA)n repeats of different extension shape the central structure of peaks and co-localize with polyadenylation efficiency element (EE) signals. ORFs with flexible peaks share common features. Transcripts are characterized by decreased half-life: this is considered peculiar of genes involved in regulatory systems with high turnover; consistently, their function affects biological processes such as cell cycle regulation or stress response. Our findings support the functional importance of flexibility peaks, suggesting that the flexible sequence may be derived by an expansion of canonical TAYRTA polyadenylation efficiency element. The flexible (TA)n repeat amplification could be the outcome of an evolutionary neofunctionalization leading to a differential 3'-end processing and expression regulation in genes with peculiar function. Our study provides a new support to the functional role of flexibility in genomes and a

  4. Use and Underlying Reasons for Duty Hour Flexibility in the Flexibility in Duty Hour Requirements for Surgical Trainees (FIRST) Trial.

    Science.gov (United States)

    Bilimoria, Karl Y; Quinn, Christopher M; Dahlke, Allison R; Kelz, Rachel R; Shea, Judy A; Rajaram, Ravi; Love, Remi; Kreutzer, Lindsey; Biester, Thomas; Yang, Anthony D; Hoyt, David B; Lewis, Frank R

    2017-02-01

    The Flexibility in Duty Hour Requirements for Surgical Trainees (FIRST) Trial randomly assigned surgical residency programs to either standard duty hour policies or flexible policies that eliminated caps on shift lengths and time off between shifts. Our objectives were to assess adherence to duty hour requirements in the Standard Policy arm and examine how often and why duty hour flexibility was used in the Flexible Policy arm. A total of 3,795 residents in the FIRST trial completed a survey in January 2016 (response rate >95%) that asked how often and why they exceeded current standard duty hour limits in both study arms. Flexible Policy interns worked more than 16 hours continuously at least once in a month more frequently than Standard Policy residents (86% vs 37.8%). Flexible Policy residents worked more than 28 hours once in a month more frequently than Standard Policy residents (PGY1: 64% vs 2.9%; PGY2 to 3: 62.4% vs 41.9%; PGY4 to 5: 52.2% vs 36.6%), but this occurred most frequently only 1 to 2 times per month. Although residents reported working more than 80 hours in a week 3 or more times in the most recent month more frequently under Flexible Policy vs Standard Policy (19.9% vs 16.2%), the difference was driven by interns (30.9% vs 19.6%), and there were no significant differences in exceeding 80 hours among PGY2 to 5 residents. The most common reasons reported for extending duty hours were facilitating care transitions (76.6%), stabilizing critically ill patients (70.7%), performing routine responsibilities (67.9%), and operating on patients known to the trainee (62.0%). There were differences in duty hours worked by residents in the Flexible vs Standard Policy arms of the FIRST trial, but it appeared that residents generally used the flexibility for patient care and educational opportunities selectively. Copyright © 2016 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  5. [Flexible ENT endoscopy--video technic].

    Science.gov (United States)

    Rasinger, G A; Horak, F

    1985-02-01

    This study discusses the solutions to the problem of documenting moving processes in the field of otolaryngology. A flexible bronchoscope and video equipment connected to it are presented as a specific solution of the problem, with ample of observations. A technical comparison is used as the basis for a discussion of the pros and cons of the video and film techniques. A successful arrangement of examination facilities illustrates the future of flexible-endoscope techniques in the field of otolaryngology.

  6. Flexibility in radiation protection legislation -the UK approach

    International Nuclear Information System (INIS)

    Beaver, P.F.; Gill, J.R.

    1980-01-01

    The case for flexibility in the formulation of radiation protection legislation and that for precise invariable requirements which are applicable to all users of ionising radiations are presented. It is asserted that greater participation on the part of persons affected in the shaping of legislation brings with it a commitment to flexibility if consensus is to be achieved. The nature of the participative and consultative processes in the UK is described. The means by which flexibility will be inbuilt into future UK legislation are discussed, taking as examples, three particular areas: a) Notification of use of ionising radiations, where flexibility needs to be introduced to take care of improved knowledge of potential risk, the avoidance of bureaucratic procedures, and the wide variation in practice from one work activity to another; b) The definition of controlled areas, where flexibility is needed to cope with the wide range of potential use situations, yet if controlled areas are to be the route to defining Category A workers, where that flexibility must be restrained to ensure proper categorysation and effective enforcement; c) The criteria for the need to appoint and for the selection of radiation protection advisers where flexibility must be invoked to ensure that any particular task is matched by the quality of the radiation protection adviser concerned. It is concluded that the proposed UK legislation will achieve flexibility where this is appropriate and cost-effective and on the other hand demand adherence to strictly expressed levels of exposure where that is appropriate. (author)

  7. Living in a Flexible Space

    Science.gov (United States)

    Canepa, Simona

    2017-10-01

    How long does a space or an object have to last? If in the past an object or a building manufacturing was designed to last as much as possible, nowadays it is designed to have a life related to the time in which it will be used. Flexibility is what characterizes a space, it’s the ability to be variable and adaptable to changes in the lives of users or in relation to the use which these will make over time. The evolution of the labour market, the difficulty of inserting within it and the need to push more and more frequent move today in the trial of living space models increasingly flexible: people, especially young people, are forced to move on territory outlining a new condition to which the flexible nomadic dwellings offer an adequate response, ensuring high functional performance in confined spaces.

  8. Thermocouple psychrometer measurements of in situ water potential changes in heated welded tuff

    International Nuclear Information System (INIS)

    Mao, Nai-hsien; Wang, H.F.

    1991-05-01

    Ten thermocouple psychrometers (TCPs) to measure water potential (WP) were installed in three holes in G-Tunnel at the Nevada Test Site as part of the Prototype Engineered Barrier System Field Tests. These integrated tests measured several parameters as a function of location and time within a few meters of a heater emplaced in welded tuff. The primary goal of the TCP experiment was to find out whether the combination of laboratory calibration and field use of the TCP can provide useful data for determining the change of moisture condition in the field. We calibrated the TCPs in NaCl solutions up to 80 degree C(176 degree F) in the laboratory. In two holes, we used rubber sleeves and packers to house TCPs, and in the third hole, we used foam. All three holes were grouted behind the TCP assemblages. Field results of the heater test showed that small temperature gradients were present for all measurements. Nevertheless, the WP calibration made the necessary correction for the nonisothermal condition. A drying and re-wetting cycle peaked at about day 140 with a WP of -65 bar in borehole P3, located below the heater. A similar cycle but reduced in scale was found at about day 175 with a WP of -45 bar in borehole P2, above the heater. This difference in drying behavior above and below the heater was also observed from neutron data and was explained as a gravity effect. As temperatures increased, the evaporation rate of pore water increased, In unfractured rock, the gas-phase flow was primarily outward. Water condensed above the heater would drain back to keep the boiling region wet, but water condensed below the heater would drain away from the boiling region. This conceptual model explained both the time and magnitude differences for data from holes above and below the heater. 7 refs., 14 figs., 2 tabs

  9. Two-dimensional flexible nanoelectronics

    Science.gov (United States)

    Akinwande, Deji; Petrone, Nicholas; Hone, James

    2014-12-01

    2014/2015 represents the tenth anniversary of modern graphene research. Over this decade, graphene has proven to be attractive for thin-film transistors owing to its remarkable electronic, optical, mechanical and thermal properties. Even its major drawback--zero bandgap--has resulted in something positive: a resurgence of interest in two-dimensional semiconductors, such as dichalcogenides and buckled nanomaterials with sizeable bandgaps. With the discovery of hexagonal boron nitride as an ideal dielectric, the materials are now in place to advance integrated flexible nanoelectronics, which uniquely take advantage of the unmatched portfolio of properties of two-dimensional crystals, beyond the capability of conventional thin films for ubiquitous flexible systems.

  10. Development of a fuel-rod simulator and small-diameter thermocouples for high-temperature, high-heat-flux tests in the Gas-Cooled Fast Reactor Core Flow Test Loop

    Energy Technology Data Exchange (ETDEWEB)

    McCulloch, R.W.; MacPherson, R.E.

    1983-03-01

    The Core Flow Test Loop was constructed to perform many of the safety, core design, and mechanical interaction tests in support of the Gas-Cooled Fast Reactor (GCFR) using electrically heated fuel rod simulators (FRSs). Operation includes many off-normal or postulated accident sequences including transient, high-power, and high-temperature operation. The FRS was developed to survive: (1) hundreds of hours of operation at 200 W/cm/sup 2/, 1000/sup 0/C cladding temperature, and (2) 40 h at 40 W/cm/sup 2/, 1200/sup 0/C cladding temperature. Six 0.5-mm type K sheathed thermocouples were placed inside the FRS cladding to measure steady-state and transient temperatures through clad melting at 1370/sup 0/C.

  11. Probabilistic Quantification of Potentially Flexible Residential Demand

    DEFF Research Database (Denmark)

    Kouzelis, Konstantinos; Mendaza, Iker Diaz de Cerio; Bak-Jensen, Birgitte

    2014-01-01

    The balancing of power systems with high penetration of renewable energy is a serious challenge to be faced in the near future. One of the possible solutions, recently capturing a lot of attention, is demand response. Demand response can only be achieved by power consumers holding loads which allow...... them to modify their normal power consumption pattern, namely flexible consumers. However flexibility, despite being constantly mentioned, is usually not properly defined and even rarer quantified. This manuscript introduces a methodology to identify and quantify potentially flexible demand...

  12. Identification of critical factors affecting flexibility in hospital construction projects.

    Science.gov (United States)

    Olsson, Nils E O; Hansen, Geir K

    2010-01-01

    This paper analyzes the dynamics relating to flexibility in a hospital project context. Three research questions are addressed: (1) When is flexibility used in the life cycle of a project? (2) What are the stakeholders' perspectives on project flexibility? And (3) What is the nature of the interaction between flexibility in the process of a project and flexibility in terms of the characteristics of a building? Flexibility is discussed from both a project management point of view and from a hospital architecture perspective. Flexibility in project life cycle and from a stakeholder perspective is examined, and the interaction between flexibility in scope lock-in and building flexibility is investigated. The results are based on case studies of four Norwegian hospital projects. Information relating to the projects has been obtained from evaluation reports, other relevant documents, and interviews. Observations were codified and analyzed based on selected parameters that represent different aspects of flexibility. One of the cases illustrates how late changes can have a significant negative impact on the project itself, contributing to delays and cost overruns. Another case illustrates that late scope lock-in on a limited part of the project, in this case related to medical equipment, can be done in a controlled manner. Project owners and users appear to have given flexibility high priority. Project management teams are less likely to embrace changes and late scope lock-in. Architects and consultants are important for translating program requirements into physical design. A highly flexible building did not stop some stakeholders from pushing for significant changes and extensions during construction.

  13. Modelling Flexible Pavement Response and Performance

    DEFF Research Database (Denmark)

    Ullidtz, Per

    This textbook is primarily concerned with models for predicting the future condition of flexible pavements, as a function of traffic loading, climate, materials, etc., using analytical-empirical methods.......This textbook is primarily concerned with models for predicting the future condition of flexible pavements, as a function of traffic loading, climate, materials, etc., using analytical-empirical methods....

  14. Long Hole Film Cooling Dataset for CFD Development . Part 1; Infrared Thermography and Thermocouple Surveys

    Science.gov (United States)

    Shyam, Vikram; Thurman, Douglas; Poinsatte, Phillip; Ameri, Ali; Eichele, Peter; Knight, James

    2013-01-01

    An experiment investigating flow and heat transfer of long (length to diameter ratio of 18) cylindrical film cooling holes has been completed. In this paper, the thermal field in the flow and on the surface of the film cooled flat plate is presented for nominal freestream turbulence intensities of 1.5 and 8 percent. The holes are inclined at 30deg above the downstream direction, injecting chilled air of density ratio 1.0 onto the surface of a flat plate. The diameter of the hole is 0.75 in. (0.01905 m) with center to center spacing (pitch) of 3 hole diameters. Coolant was injected into the mainstream flow at nominal blowing ratios of 0.5, 1.0, 1.5, and 2.0. The Reynolds number of the freestream was approximately 11,000 based on hole diameter. Thermocouple surveys were used to characterize the thermal field. Infrared thermography was used to determine the adiabatic film effectiveness on the plate. Hotwire anemometry was used to provide flowfield physics and turbulence measurements. The results are compared to existing data in the literature. The aim of this work is to produce a benchmark dataset for Computational Fluid Dynamics (CFD) development to eliminate the effects of hole length to diameter ratio and to improve resolution in the near-hole region. In this report, a Time-Filtered Navier Stokes (TFNS), also known as Partially Resolved Navier Stokes (PRNS), method that was implemented in the Glenn-HT code is used to model coolant-mainstream interaction. This method is a high fidelity unsteady method that aims to represent large scale flow features and mixing more accurately.

  15. Flexible forms of working hours

    OpenAIRE

    Knapp, Viktor

    2017-01-01

    66 Abstract - Flexible forms of working hours This diploma thesis deals with the flexible forms of working hours and its goal is to describe this issue in intelligible and comprehensive way. It is being very interesting and current theme which is to a great extent not subject to direct legal regulations and provides its contracting parties with a big amount of freedom of contract. This fact assists in bigger flexibilization of labour market and represents a significant instrument in the fight...

  16. Transcervical heller myotomy using flexible endoscopy.

    Science.gov (United States)

    Spaun, Georg O; Dunst, Christy M; Arnold, Brittany N; Martinec, Danny V; Cassera, Maria A; Swanström, Lee L

    2010-12-01

    Esophageal achalasia is most commonly treated by laparoscopic myotomy. Transesophageal approaches using flexible endoscopy have recently been described. We hypothesized that using techniques and flexible instruments from our NOTES experience through a small cervical incision would be a safer and less traumatic route for esophageal myotomy. The purpose of this study was to evaluate the feasibility, safety, and success rate of using flexible endoscopes to perform anterior or posterior Heller myotomy via a transcervical approach. This animal (porcine) and human cadaver study was conducted at the Legacy Research and Technology Center. Mediastinal operations on ten live, anesthetized pigs and two human cadavers were performed using standard flexible endoscopes through a small incision at the supra-sternal notch. The esophagus was dissected to the phreno-esophageal junction using balloon dilatation in the peri-esophageal space followed by either anterior or posterior distal esophageal myotomy. Success rate was recorded of esophageal dissection to the diaphragm and proximal stomach, anterior and posterior myotomy, perforation, and complication rates. Dissection of the esophagus to the diaphragm and performing esophageal myotomy was achieved in 100% of attempts. Posterior Heller myotomy was always extendable onto the gastric wall, while anterior gastric extension of the myotomy was found to be more difficult (4/4 and 2/8, respectively; P = 0.061). Heller myotomy through a small cervical incision using flexible endoscopes is feasible. A complete Heller myotomy was performed with a higher success rate posteriorly possibly due to less anatomic interference.

  17. Interfacial characterization of flexible hybrid electronics

    Science.gov (United States)

    Najafian, Sara; Amirkhizi, Alireza V.; Stapleton, Scott

    2018-03-01

    Flexible Hybrid Electronics (FHEs) are the new generation of electronics combining flexible plastic film substrates with electronic devices. Besides the electrical features, design improvements of FHEs depend on the prediction of their mechanical and failure behavior. Debonding of electronic components from the flexible substrate is one of the most common and critical failures of these devices, therefore, the experimental determination of material and interface properties is of great importance in the prediction of failure mechanisms. Traditional interface characterization involves isolated shear and normal mode tests such as the double cantilever beam (DCB) and end notch flexure (ENF) tests. However, due to the thin, flexible nature of the materials and manufacturing restrictions, tests mirroring traditional interface characterization experiments may not always be possible. The ideal goal of this research is to design experiments such that each mode of fracture is isolated. However, due to the complex nonlinear nature of the response and small geometries of FHEs, design of the proper tests to characterize the interface properties can be significantly time and cost consuming. Hence numerical modeling has been implemented to design these novel characterization experiments. This research involves loading case and specimen geometry parametric studies using numerical modeling to design future experiments where either shear or normal fracture modes are dominant. These virtual experiments will provide a foundation for designing similar tests for many different types of flexible electronics and predicting the failure mechanism independent of the specific FHE materials.

  18. Propulsion via flexible flapping in granular media

    Science.gov (United States)

    Peng, Zhiwei; Ding, Yang; Pietrzyk, Kyle; Elfring, Gwynn; Pak, On Shun

    2017-11-01

    Biological locomotion in nature is often achieved by the interaction between a flexible body and its surrounding medium. The interaction of a flexible body with granular media is less understood compared with viscous fluids partially due to its complex rheological properties. In this work, we explore the effect of flexibility on granular propulsion by considering a simple mechanical model in which a rigid rod is connected to a torsional spring that is under a displacement actuation using a granular resistive force theory. Through a combined numerical and asymptotic investigation, we characterize the propulsive dynamics of such a flexible flapper in relation to the actuation amplitude and spring stiffness, and we compare these dynamics with those observed in a viscous fluid. In addition, we demonstrate that the maximum possible propulsive force can be obtained in the steady propulsion limit with a finite spring stiffness and large actuation amplitude. These results may apply to the development of synthetic locomotive systems that exploit flexibility to move through complex terrestrial media. Funding for Z.P. and Y.D. was partially provided by NSFC 394 Grant No. 11672029 and NSAF-NSFC Grant No. U1530401.

  19. Wind-Induced Reconfigurations in Flexible Branched Trees

    Science.gov (United States)

    Ojo, Oluwafemi; Shoele, Kourosh

    2017-11-01

    Wind induced stresses are the major mechanical cause of failure in trees. We know that the branching mechanism has an important effect on the stress distribution and stability of a tree in the wind. Eloy in PRL 2011, showed that Leonardo da Vinci's original observation which states the total cross section of branches is conserved across branching nodes is the best configuration for resisting wind-induced fracture in rigid trees. However, prediction of the fracture risk and pattern of a tree is also a function of their reconfiguration capabilities and how they mitigate large wind-induced stresses. In this studies through developing an efficient numerical simulation of flexible branched trees, we explore the role of the tree flexibility on the optimal branching. Our results show that the probability of a tree breaking at any point depends on both the cross-section changes in the branching nodes and the level of tree flexibility. It is found that the branching mechanism based on Leonardo da Vinci's original observation leads to a uniform stress distribution over a wide range of flexibilities but the pattern changes for more flexible systems.

  20. Towards Flexibility Detection in Device-Level Energy Consumption

    DEFF Research Database (Denmark)

    Neupane, Bijay; Pedersen, Torben Bach; Thiesson, Bo

    2014-01-01

    The increasing drive towards green energy has boosted the installation of Renewable Energy Sources (RES). Increasing the share of RES in the power grid requires demand management by flexibility in the consumption. In this paper, we perform a state-of-the-art analysis on the flexibility and operat......The increasing drive towards green energy has boosted the installation of Renewable Energy Sources (RES). Increasing the share of RES in the power grid requires demand management by flexibility in the consumption. In this paper, we perform a state-of-the-art analysis on the flexibility...... and operation patterns of the devices in a set of real households. We propose a number of specific pre-processing steps such as operation stage segmentation, and aberrant operation duration removal to clean device level data. Further, we demonstrate various device operation properties such as hourly and daily...... regularities and patterns and the correlation between operating different devices. Subsequently, we show the existence of detectable time and energy flexibility in device operations. Finally, we provide various results providing a foundation for load- and flexibility-detection and -prediction at the device...

  1. Towards constraint-based aggregation of energy flexibilities

    DEFF Research Database (Denmark)

    Valsomatzis, Emmanouil; Pedersen, Torben Bach; Abello, Alberto

    2016-01-01

    present the problem of aggregating energy flexibilities taking into account grid capacity limitations and introduce a heuristic aggregation technique. We show through an experimental setup that our proposed technique, compared to a baseline approach, not only leads to a valid unit commitment result......The aggregation of energy flexibilities enables individual producers and/or consumers with small loads to directly participate in the emerging energy markets. On the other hand, aggregation of such flexibilities might also create problems to the operation of the electrical grid. In this paper, we...

  2. Flexibility: the grid knows how to cope

    International Nuclear Information System (INIS)

    Boulanger, Vincent

    2017-01-01

    As variable energy sources, such as wind power and photovoltaic solar power, are more and more penetrating into the electric power mix, flexibility is therefore a growing challenge, notably concerning the power demand variability. As a matter of fact, experts show that, contrary to the popular belief, there is no needs to use thermal power plants, power-to-gas systems or energy storage for that, thanks to innovative power flexibility and load management tools and technologies (nuclear power plants are also gaining the aptitude to be more flexible than before). The frequency issue is addressed

  3. Challenges in navigational strategies for flexible endoscopy

    NARCIS (Netherlands)

    van der Stap, N.; van der Heijden, Ferdinand; Broeders, Ivo Adriaan Maria Johannes

    Automating flexible endoscope navigation could lead to an increase in patient safety for endoluminal therapeutic procedures. Additionally, it may decrease the costs of diagnostic flexible endoscope procedures by shortening the learning curve and increasing the efficiency of insertion. Earlier

  4. HPOTP low-speed flexible rotor balancing, phase 1

    Science.gov (United States)

    Giordano, J.; Zorzi, E.

    1985-01-01

    A method was developed that shows promise in overcoming many balancing limitations. This method establishes one or more windows for low speed, out-of-housing balancing of flexible rotors. These windows are regions of speed and support flexibility where two conditions are simultaneously fulfilled. First, the rotor system behaves flexibly; therefore, there is separation among balance planes. Second, the response due to balance weights is large enough to reliably measure. The analytic formulation of the low-speed flexible rotor balancing method is described. The results of proof-of-principle tests conducted under the program are presented. Based on this effort, it is concluded that low speed flexible rotor balancing is a viable technology. In particular, the method can be used to balance a rotor bearing system at low speed which results in smooth operation above more than one bending critical speed. Furthermore, this balancing methodology is applicable to SSME turbopump rotors.

  5. Flexible nanovectors

    International Nuclear Information System (INIS)

    Pugno, Nicola M

    2008-01-01

    In this paper we show that the control of adhesion in highly flexible (a property that could be crucial for smart drug delivery but which is still ignored in the literature) nanovectors can help in smartly targeting and delivering the drug. The existence of and the conditions for activating and controlling a super-adhesive state are addressed. Even if such a state has never been observed in nanovectors, our calculations, as well as observations in spiders and geckos, suggest its existence and feasible control. Control of the competition between the drag and the adhesive force is exploited to improve the targeting ability and a hierarchical model is applied to describe a real vasculature. The high flexibility of the nanovector is used to smartly deliver the drug only during adhesion by nanopumping or, as a limiting case, by the new concept of 'adhesion induced nanovector implosion'; a liquid drop analogy is utilized for the calculations. Fast (pumping) and slow (diffusion) drug deliveries can thus be separately controlled by controlling the size and shape of the nanovector. Multiple stage nanovectors are also briefly discussed, mimicking aerospace vector strategies.

  6. Flexible nanovectors

    Science.gov (United States)

    Pugno, Nicola M.

    2008-11-01

    In this paper we show that the control of adhesion in highly flexible (a property that could be crucial for smart drug delivery but which is still ignored in the literature) nanovectors can help in smartly targeting and delivering the drug. The existence of and the conditions for activating and controlling a super-adhesive state are addressed. Even if such a state has never been observed in nanovectors, our calculations, as well as observations in spiders and geckos, suggest its existence and feasible control. Control of the competition between the drag and the adhesive force is exploited to improve the targeting ability and a hierarchical model is applied to describe a real vasculature. The high flexibility of the nanovector is used to smartly deliver the drug only during adhesion by nanopumping or, as a limiting case, by the new concept of 'adhesion induced nanovector implosion'; a liquid drop analogy is utilized for the calculations. Fast (pumping) and slow (diffusion) drug deliveries can thus be separately controlled by controlling the size and shape of the nanovector. Multiple stage nanovectors are also briefly discussed, mimicking aerospace vector strategies.

  7. Operational Flexibility Responses to Environmental Uncertainties

    OpenAIRE

    Miller, Kent D.

    1994-01-01

    This study develops and tests a behavioral model of organizational changes in operational flexibility. Regression results using an international data set provide strong support for the general proposition that uncertainties associated with different environmental components--poitical, government policy, macroeconomic, competitive, input and product demand uncertainties--have different implications for firm internal, locational, and supploer flexibility. Slack acts as a buffer attenuating, a...

  8. Flexible Electronics Development Supported by NASA

    Science.gov (United States)

    Baumann, Eric

    2014-01-01

    The commercial electronics industry is leading development in most areas of electronics for NASA applications; however, working in partnership with industry and the academic community, results from NASA research could lead to better understanding and utilization of electronic materials by the flexible electronics industry. Innovative ideas explored by our partners in industry and the broader U.S. research community help NASA execute our missions and bring new American products and services to the global technology marketplace. [Mike Gazarik, associate administrator for Space Technology, NASA Headquarters, Washington DC] This presentation provides information on NASA needs in electronics looking towards the future, some of the work being supported by NASA in flexible electronics, and the capabilities of the Glenn Research Center supporting the development of flexible electronics.

  9. Workforce flexibility - in defence of professional healthcare work.

    Science.gov (United States)

    Wise, Sarah; Duffield, Christine; Fry, Margaret; Roche, Michael

    2017-06-19

    Purpose The desirability of having a more flexible workforce is emphasised across many health systems yet this goal is as ambiguous as it is ubiquitous. In the absence of empirical studies in healthcare that have defined flexibility as an outcome, the purpose of this paper is to draw on classic management and sociological theory to reduce this ambiguity. Design/methodology/approach The paper uses the Weberian tool of "ideal types". Key workforce reforms are held against Atkinson's model of functional flexibility which aims to increase responsiveness and adaptability through multiskilling, autonomy and teams; and Taylorism which seeks stability and reduced costs through specialisation, fragmentation and management control. Findings Appeals to an amorphous goal of increasing workforce flexibility make an assumption that any reform will increase flexibility. However, this paper finds that the work of healthcare professionals already displays most of the essential features of functional flexibility but many widespread reforms are shifting healthcare work in a Taylorist direction. This contradiction is symptomatic of a failure to confront inevitable trade-offs in reform: between the benefits of specialisation and the costs of fragmentation; and between management control and professional autonomy. Originality/value The paper questions the conventional conception of "the problem" of workforce reform as primarily one of professional control over tasks. Holding reforms against the ideal types of Taylorism and functional flexibility is a simple, effective way the costs and benefits of workforce reform can be revealed.

  10. Flexible Laser Metal Cutting

    DEFF Research Database (Denmark)

    Villumsen, Sigurd; Jørgensen, Steffen Nordahl; Kristiansen, Morten

    2014-01-01

    This paper describes a new flexible and fast approach to laser cutting called ROBOCUT. Combined with CAD/CAM technology, laser cutting of metal provides the flexibility to perform one-of-a-kind cutting and hereby realises mass production of customised products. Today’s laser cutting techniques...... possess, despite their wide use in industry, limitations regarding speed and geometry. Research trends point towards remote laser cutting techniques which can improve speed and geometrical freedom and hereby the competitiveness of laser cutting compared to fixed-tool-based cutting technology...... such as punching. This paper presents the concepts and preliminary test results of the ROBOCUT laser cutting technology, a technology which potentially can revolutionise laser cutting....

  11. Conductive polymer/metal composites for interconnect of flexible devices

    Science.gov (United States)

    Kawakita, Jin; Hashimoto Shinoda, Yasuo; Shuto, Takanori; Chikyow, Toyohiro

    2015-06-01

    An interconnect of flexible and foldable devices based on advanced electronics requires high electrical conductivity, flexibility, adhesiveness on a plastic substrate, and efficient productivity. In this study, we investigated the applicability of a conductive polymer/metal composite to the interconnect of flexible devices. By combining an inkjet process and a photochemical reaction, micropatterns of a polypyrrole/silver composite were formed on flexible plastic substrates with an average linewidth of approximately 70 µm within 10 min. The conductivity of the composite was improved to 6.0 × 102 Ω-1·cm-1. From these results, it is expected that the conducting polymer/metal composite can be applied to the microwiring of flexible electronic devices.

  12. Why monetary board: Monetary board and endogenic price flexibility

    Directory of Open Access Journals (Sweden)

    Bašić Tamara

    2004-01-01

    Full Text Available The paper presents a model which proves that a unilateral exchange rate fixing, i.e. monetary board, as opposed to certain opinions, is an optimal policy since it increases flexibility of nominal prices, which is the ultimate goal of a flexible exchange rate policy. A suitable calibration of the model shows that the higher the initial price flexibility, the lower the difference needed for "utility increase" in getting the producers to switch from fixed to flexible prices. The results obtained in all cases indicate that exchange rate fixing increases price flexibility, which proves that a unilateral exchange rate fixing, i.e. monetary board, could be an optimal monetary policy.

  13. APPLICATIONS OF RESEARCH TO THE PROBLEM OF INSTRUCTIONAL FLEXIBILITY.

    Science.gov (United States)

    SARTAIN, HARRY W.

    SELECTED RESEARCH ON THE PROBLEM OF INSTRUCTIONAL FLEXIBILITY IS SURVEYED AND DISCUSSED. BROAD TOPICS OF DISCUSSION ARE DEPARTMENTALIZATION, HOMOGENEOUS SECTIONING, INTERCLASS ABILITY SECTIONING, THE EXTENT OF VARIABILITY IN READING DEVELOPMENT, AND PRACTICES THAT MAY INCREASE FLEXIBILITY. AMONG THOSE PRACTICES TO INCREASE FLEXIBILITY ARE TEAM…

  14. Chemically modified graphene based supercapacitors for flexible and miniature devices

    Science.gov (United States)

    Ghosh, Debasis; Kim, Sang Ouk

    2015-09-01

    Rapid progress in the portable and flexible electronic devises has stimulated supercapacitor research towards the design and fabrication of high performance flexible devices. Recent research efforts for flexible supercapacitor electrode materials are highly focusing on graphene and chemically modified graphene owing to the unique properties, including large surface area, high electrical and thermal conductivity, excellent mechanical flexibility, and outstanding chemical stability. This invited review article highlights current status of the flexible electrode material research based on chemically modified graphene for supercapacitor application. A variety of electrode architectures prepared from chemically modified graphene are summarized in terms of their structural dimensions. Novel prototypes for the supercapacitor aiming at flexible miniature devices, i.e. microsupercapacitor with high energy and power density are highlighted. Future challenges relevant to graphene-based flexible supercapacitors are also suggested. [Figure not available: see fulltext.

  15. Cognitive flexibility in drawings of bilingual children.

    Science.gov (United States)

    Adi-Japha, Esther; Berberich-Artzi, Jennie; Libnawi, Afaf

    2010-01-01

    A. Karmiloff-Smith's (1990) task of drawing a nonexistent object is considered to be a measure of cognitive flexibility. The notion of earlier emergence of cognitive flexibility in bilingual children motivated the current researchers to request 4- and 5-year-old English-Hebrew and Arabic-Hebrew bilingual children and their monolingual peers to draw a flower and a house that do not exist (N=80). Bilinguals exhibited a significantly higher rate of interrepresentational flexibility in their drawings (e.g., "a giraffe flower,"a chair-house," found in 28 of 54 drawings), whereas the level of complex intrarepresentational change was similar across groups. Interrepresentational drawings were previously reported only for children older than 7 years. The specific mechanisms by which bilinguals' language experience may lead to interrepresentational flexibility are discussed. © 2010 The Authors. Child Development © 2010 Society for Research in Child Development, Inc.

  16. Flexible metal bellows

    CERN Multimedia

    CERN PhotoLab

    1975-01-01

    A set of flexible metal bellows being fatigue-tested by repeated offset motion. Such bellows assemblies were used in the SPS vacuum system at places where , for instance, beam stoppers and collimators had to be moved frequently in and out of the beam path.

  17. A Skin-attachable Flexible Piezoelectric Pulse Wave Energy Harvester

    International Nuclear Information System (INIS)

    Yoon, Sunghyun; Cho, Young-Ho

    2014-01-01

    We present a flexible piezoelectric generator, capable to harvest energy from human arterial pulse wave on the human wrist. Special features and advantages of the flexible piezoelectric generator include the multi-layer device design with contact windows and the simple fabrication process for the higher flexibility with the better energy harvesting efficiency. We have demonstrated the design effectiveness and the process simplicity of our skin- attachable flexible piezoelectric pulse wave energy harvester, composed of the sensitive P(VDF-TrFE) piezoelectric layer on the flexible polyimide support layer with windows. We experimentally characterize and demonstrate the energy harvesting capability of 0.2∼1.0μW in the Human heart rate range on the skin contact area of 3.71cm 2 . Additional physiological and/or vital signal monitoring devices can be fabricated and integrated on the skin attachable flexible generator, covered by an insulation layer; thus demonstrating the potentials and advantages of the present device for such applications to the flexible multi-functional selfpowered artificial skins, capable to detect physiological and/or vital signals on Human skin using the energy harvested from arterial pulse waves

  18. Extremely flexible nanoscale ultrathin body silicon integrated circuits on plastic.

    Science.gov (United States)

    Shahrjerdi, Davood; Bedell, Stephen W

    2013-01-09

    In recent years, flexible devices based on nanoscale materials and structures have begun to emerge, exploiting semiconductor nanowires, graphene, and carbon nanotubes. This is primarily to circumvent the existing shortcomings of the conventional flexible electronics based on organic and amorphous semiconductors. The aim of this new class of flexible nanoelectronics is to attain high-performance devices with increased packing density. However, highly integrated flexible circuits with nanoscale transistors have not yet been demonstrated. Here, we show nanoscale flexible circuits on 60 Å thick silicon, including functional ring oscillators and memory cells. The 100-stage ring oscillators exhibit the stage delay of ~16 ps at a power supply voltage of 0.9 V, the best reported for any flexible circuits to date. The mechanical flexibility is achieved by employing the controlled spalling technology, enabling the large-area transfer of the ultrathin body silicon devices to a plastic substrate at room temperature. These results provide a simple and cost-effective pathway to enable ultralight flexible nanoelectronics with unprecedented level of system complexity based on mainstream silicon technology.

  19. Graphene-Tapered ZnO Nanorods Array as a Flexible Antireflection Layer

    Directory of Open Access Journals (Sweden)

    Taeseup Song

    2015-01-01

    Full Text Available Flexible solar cells have drawn a great deal of attention due to their various advantages including deformable and wearable characteristics. In the solar cells, the antireflection layer plays an important role in the improvement in the conversion efficiency by increasing the light transmission and suppressing the Fresnel refraction. For the successful implantation of the antireflection layer into the flexible solar cells, the flexible mechanical property of the antireflection layer is also necessary. However, the study on flexible antireflection layer for the flexible solar cells or optoelectronics is still lacking. In this study, we report the graphene-tapered ZnO nanorods array as a flexible antireflection layer for the application in flexible solar cells. Flexible two-dimensional graphene sheet and the tapered morphology of ZnO nanorods enable conformal coverage on the flexible substrate with curved surface and significant improvements in antireflection properties, respectively.

  20. 5 CFR 532.513 - Flexible and compressed work schedules.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Flexible and compressed work schedules... REGULATIONS PREVAILING RATE SYSTEMS Premium Pay and Differentials § 532.513 Flexible and compressed work schedules. Federal Wage System employees who are authorized to work flexible and compressed work schedules...

  1. Flexibility in water management as an intra-organisational issue

    NARCIS (Netherlands)

    Wessel, van M.; Buuren, van R.; Woerkum, van C.

    2015-01-01

    This paper is a case study of a team of Dutch water managers who saw that to achieve flexibility in planning they needed to engage with organisational control requirements. Rather than approaching flexibility normatively, as much planning literature does, this paper presents a case of flexibility

  2. Nanocarbon-Based Materials for Flexible All-Solid-State Supercapacitors.

    Science.gov (United States)

    Lv, Tian; Liu, Mingxian; Zhu, Dazhang; Gan, Lihua; Chen, Tao

    2018-04-01

    Because of the rapid development of flexible electronics, it is important to develop high-performance flexible energy-storage devices, such as supercapacitors and metal-ion batteries. Compared with metal-ion batteries, supercapacitors exhibit higher power density, longer cycling life, and excellent safety, and they can be easily fabricated into all-solid-state devices by using polymer gel electrolytes. All-solid-state supercapacitors (ASSSCs) have the advantages of being lightweight and flexible, thus showing great potential to be used as power sources for flexible portable electronics. Because of their high specific surface area and excellent electrical and mechanical properties, nanocarbon materials (such as carbon nanotubes, graphene, carbon nanofibers, and so on) have been widely used as efficient electrode materials for flexible ASSSCs, and great achievements have been obtained. Here, the recent advances in flexible ASSSCs are summarized, from design strategies to fabrication techniques for nanocarbon electrodes and devices. Current challenges and future perspectives are also discussed. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Flexible and tunable silicon photonic circuits on plastic substrates

    Science.gov (United States)

    Chen, Yu; Li, Huan; Li, Mo

    2012-09-01

    Flexible microelectronics has shown tremendous promise in a broad spectrum of applications, especially those that cannot be addressed by conventional microelectronics in rigid materials and constructions. These unconventional yet important applications range from flexible consumer electronics to conformal sensor arrays and biomedical devices. A recent paradigm shift in implementing flexible electronics is to physically transfer highly integrated devices made in high-quality, crystalline semiconductors on to plastic substrates. Here we demonstrate a flexible form of silicon photonics using the transfer-and-bond fabrication method. Photonic circuits including interferometers and resonators have been transferred onto flexible plastic substrates with preserved functionalities and performance. By mechanically deforming, the optical characteristics of the devices can be tuned reversibly over a remarkably large range. The demonstration of the new flexible photonic systems based on the silicon-on-plastic (SOP) platform could open the door to many future applications, including tunable photonics, optomechanical sensors and biomechanical and bio-photonic probes.

  4. Towards automated visual flexible endoscope navigation.

    Science.gov (United States)

    van der Stap, Nanda; van der Heijden, Ferdinand; Broeders, Ivo A M J

    2013-10-01

    The design of flexible endoscopes has not changed significantly in the past 50 years. A trend is observed towards a wider application of flexible endoscopes with an increasing role in complex intraluminal therapeutic procedures. The nonintuitive and nonergonomical steering mechanism now forms a barrier in the extension of flexible endoscope applications. Automating the navigation of endoscopes could be a solution for this problem. This paper summarizes the current state of the art in image-based navigation algorithms. The objectives are to find the most promising navigation system(s) to date and to indicate fields for further research. A systematic literature search was performed using three general search terms in two medical-technological literature databases. Papers were included according to the inclusion criteria. A total of 135 papers were analyzed. Ultimately, 26 were included. Navigation often is based on visual information, which means steering the endoscope using the images that the endoscope produces. Two main techniques are described: lumen centralization and visual odometry. Although the research results are promising, no successful, commercially available automated flexible endoscopy system exists to date. Automated systems that employ conventional flexible endoscopes show the most promising prospects in terms of cost and applicability. To produce such a system, the research focus should lie on finding low-cost mechatronics and technologically robust steering algorithms. Additional functionality and increased efficiency can be obtained through software development. The first priority is to find real-time, robust steering algorithms. These algorithms need to handle bubbles, motion blur, and other image artifacts without disrupting the steering process.

  5. An Overview of the Development of Flexible Sensors.

    Science.gov (United States)

    Han, Su-Ting; Peng, Haiyan; Sun, Qijun; Venkatesh, Shishir; Chung, Kam-Sing; Lau, Siu Chuen; Zhou, Ye; Roy, V A L

    2017-09-01

    Flexible sensors that efficiently detect various stimuli relevant to specific environmental or biological species have been extensively studied due to their great potential for the Internet of Things and wearable electronics applications. The application of flexible and stretchable electronics to device-engineering technologies has enabled the fabrication of slender, lightweight, stretchable, and foldable sensors. Here, recent studies on flexible sensors for biological analytes, ions, light, and pH are outlined. In addition, contemporary studies on device structure, materials, and fabrication methods for flexible sensors are discussed, and a market overview is provided. The conclusion presents challenges and perspectives in this field. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Flexible receiver adapter formal design review

    International Nuclear Information System (INIS)

    Krieg, S.A.

    1995-01-01

    This memo summarizes the results of the Formal (90%) Design Review process and meetings held to evaluate the design of the Flexible Receiver Adapters, support platforms, and associated equipment. The equipment is part of the Flexible Receiver System used to remove, transport, and store long length contaminated equipment and components from both the double and single-shell underground storage tanks at the 200 area tank farms

  7. Role of Flexibility in Sustainable Port Development

    NARCIS (Netherlands)

    Taneja, P.; Vellinga, T.; Ros, R.

    2012-01-01

    Sustainability has become a high profile objective in all aspects of our lives, including the development of our infrastructures. Flexibility can enhance sustainability endeavors, yet its contribution is not clear to most. In this paper we investigate the role of flexibility in sustainable port

  8. Quality and workflow integration in flexible manufacturing

    NARCIS (Netherlands)

    ten Dam, Dennis

    2012-01-01

    In recognising the relevance of production networks and flexible manufacturing, CNC Worknet aims to be a company that approaches the new era of flexible manufacturing by developing a novel business model that combines the technologies of e-Business with production networks. This business model is

  9. Flexible Power Control of Photovoltaic Systems

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Sangwongwanich, Ariya; Yang, Yongheng

    2018-01-01

    With a still increasing penetration level of grid-connected photovoltaic (PV) systems, more advanced and flexible control functionalities are demanded. To ensure a smooth and friendly integration between the PV systems and the grid, the power generated by the PV system needs to be flexible...

  10. The influence of flexible branches in flexible polymers

    International Nuclear Information System (INIS)

    Wescott, J.T.

    1998-06-01

    In this work the influence of branches in flexible polymer systems has been investigated by consideration of (1) the behaviour of isolated poly-α-olefin chains and (2) the p -T phase behaviour of poly(4-methylpentene-1)(P4MP1). Molecular dynamics simulations of isolated poly-α-olefins were performed in order to gauge directly the effect of molecular structure on chain dimensions, flexibility (via the persistence length) and shape. Under Θ-conditions the addition of short linear branches was shown to increase the flexibility of the backbone. In conditions of good solvent, however, the effect of longer and bulkier branches was to increase the persistence length and average size of the coil with the arrangement of side chain atoms making a small difference. The side branches themselves also affected the solvent conditions experienced by the backbone, behaving much like bound solvent. Consideration of ethylene-α-olefin copolymers, where the branch content was varied from 0-50%, showed that under good solvent conditions the branches increased the chain stiffness only when the gap between side branches was less than five backbone carbon atoms. The backbone torsions were also shown to play an important role in determining these trends. For comparison with the above simulations, persistence length values for polyethylene (= 7.3±0.2A) and P4MP1 (=7.6±0.3A) were measured experimentally by neutron scattering in dilute solution. A value of 6.7±0.5 for the characteristic ratio of PE was also calculated. To investigate the role of a bulky side group in crystalline phases, wide angle X-ray diffraction experiments using a Hikosaka pressure cell were performed on P4MP1. Computer modelling, utilising the experimental data obtained, determined the structure of a disordered phase produced at room temperature and a new high pressure/high temperature phase. The disordered phase was found to be due to a collapse of the backbone combined with some disordering of the side chains

  11. Flexible removable partial dentures: a basic overview.

    Science.gov (United States)

    Hill, Edward E; Rubel, Barry; Smith, John B

    2014-01-01

    For many years, flexible resin materials have been available for fabricating removable partial denture (RPD) prostheses. Using a nonrigid material for the major connector or other components of an RPD may be a consideration for certain patients. Except for the promotional literature that has been written for flexible resin dentures, there is very little information available in the dental literature concerning nonrigid RPDs. As a result, the decision to use this treatment option depends on the judgment and experience of the dentist and fabricating laboratory. This article summarizes clinically pertinent information about flexible, nonrigid partial dentures.

  12. [Flexibility competencies: emotional organization management].

    Science.gov (United States)

    Caballero Muñoz, Domingo; Blanco Prieto, Antonio

    2007-11-01

    The aim of this article is to analyse the transferral of flexibility from contemporary organizations to workers. Through the approach of management by competencies, organizations try to develop in their workers behaviours that are related to efficient job performance. In order to appraise the importance of this approach, we used a critical-rational perspective to discuss the productivity demands that are characteristic of advanced industrial societies. The article shows how the link between workers' flexibility management and their emotional competencies affects their lives, which, like the organizations, should be versatile and adaptable to change.

  13. Polymer electronics a flexible technology

    CERN Document Server

    Technology, Rapra

    2009-01-01

    The worldwide market for polymer electronic products has been estimated to be worth up to £15 billion by 2015 and the opportunity for new markets could be as high as £125 billion by 2025.'The rapid development of polymer electronics has revealed the possibility for transforming the electronics market by offering lighter, flexible and more cost effective alternatives to conventional materials and products. With applications ranging from printed, flexible conductors and novel semiconductor components to intelligent labels and large area displays and solar panels, products that were previously un

  14. Movable MEMS Devices on Flexible Silicon

    KAUST Repository

    Ahmed, Sally

    2013-05-05

    Flexible electronics have gained great attention recently. Applications such as flexible displays, artificial skin and health monitoring devices are a few examples of this technology. Looking closely at the components of these devices, although MEMS actuators and sensors can play critical role to extend the application areas of flexible electronics, fabricating movable MEMS devices on flexible substrates is highly challenging. Therefore, this thesis reports a process for fabricating free standing and movable MEMS devices on flexible silicon substrates; MEMS flexure thermal actuators have been fabricated to illustrate the viability of the process. Flexure thermal actuators consist of two arms: a thin hot arm and a wide cold arm separated by a small air gap; the arms are anchored to the substrate from one end and connected to each other from the other end. The actuator design has been modified by adding etch holes in the anchors to suit the process of releasing a thin layer of silicon from the bulk silicon substrate. Selecting materials that are compatible with the release process was challenging. Moreover, difficulties were faced in the fabrication process development; for example, the structural layer of the devices was partially etched during silicon release although it was protected by aluminum oxide which is not attacked by the releasing gas . Furthermore, the thin arm of the thermal actuator was thinned during the fabrication process but optimizing the patterning and etching steps of the structural layer successfully solved this problem. Simulation was carried out to compare the performance of the original and the modified designs for the thermal actuators and to study stress and temperature distribution across a device. A fabricated thermal actuator with a 250 μm long hot arm and a 225 μm long cold arm separated by a 3 μm gap produced a deflection of 3 μm before silicon release, however, the fabrication process must be optimized to obtain fully functioning

  15. Experimental Research on Fluid Coupling Flexible Actuator

    Directory of Open Access Journals (Sweden)

    Xiangli Zeng

    2018-02-01

    Full Text Available In the field of micromechanics, piezoelectric actuator has attracted great attention for its high-frequency response, high displacement resolution, and high output force. However, its prospect of practical application has been largely limited by the displacement of micrometer. A fluid coupling flexible actuator was proposed, which utilizes resonance to enlarge the output displacement. The actuator uses a piezoelectric oscillator as an excitation source, fluid as the transmission medium and a flexible diaphragm for the displacement output. On the condition that the fluid is inviscid and incompressible, mathematical formulation of the membrane vibration theory has been analyzed. Then, the prototype is made. The displacement is amplified 21 times to 1.106 mm when driving frequency is 127 Hz. The flexible diaphragm appears the largest displacement output when driving frequency is close to one of the system’s natural frequency. Then, the points with zero amplitude form a circle on the surface of flexible diaphragm and the movement direction of the flexible diaphragm is opposite on different sides of the circle. In fact, rather than vibrates at the first resonance frequency, the membrane in the essay is vibrating at a certain higher-order resonance frequency. The experimental results are mainly consistent with the theoretical analysis.

  16. Granular shear flows of flexible rod-like particles

    Science.gov (United States)

    Guo, Y.; Curtis, J.; Wassgren, C.; Ketterhagen, W.; Hancock, B.

    2013-06-01

    Flexible particles are widely encountered in nature, e.g., stalks of plants, fiberglass particles, and ceramic nanofibers. Early studies indicated that the deformability of particles has a significant impact on the properties of granular materials and fiber suspensions. In this study, shear flows of flexible particles are simulated using the Discrete Element Method (DEM) to explore the effect of particle flexibility on the flow behavior and constitutive laws. A flexible particle is formed by connecting a number of constituent spheres in a straight line using elastic bonds. The forces/moments due to the normal, tangential, bending, and torsional deformation of a bond resist the relative movement between two bonded constituent spheres. The bond stiffness determines how difficult it is to make a particle deform, and the bond damping accounts for the energy dissipation in the particle vibration process. The simulation results show that elastically bonded particles have smaller coefficients of restitution compared to rigidly connected particles, due to the fact that kinetic energy is partially converted to potential energy in a contact between flexible particles. The coefficient of restitution decreases as the bond stiffness decreases and the bond damping coefficient increases. As a result, smaller stresses are obtained for granular flows of the flexible particles with smaller bond stiffness and larger bond damping coefficient.

  17. Cognitive flexibility in young children: General or task-specific capacity?

    Science.gov (United States)

    Deák, Gedeon O; Wiseheart, Melody

    2015-10-01

    Cognitive flexibility is the ability to adapt to changing tasks or problems. To test whether cognitive flexibility is a coherent cognitive capacity in young children, we tested 3- to 5-year-olds' performance on two forms of task switching, rule-based (Three Dimension Changes Card Sorting, 3DCCS) and inductive (Flexible Induction of Meaning-Animates and Objects, FIM-Ob and FIM-An), as well as tests of response speed, verbal working memory, inhibition, and reasoning. Results suggest that cognitive flexibility is not a globally coherent trait; only the two inductive word-meaning (FIM) tests showed high inter-test coherence. Task- and knowledge-specific factors also determine children's flexibility in a given test. Response speed, vocabulary size, and causal reasoning skills further predicted individual and age differences in flexibility, although they did not have the same predictive relation with all three flexibility tests. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. The productivity and work load in flexible production systems

    NARCIS (Netherlands)

    Rhijn, J.W. van; Looze, M.P. de; Schoenmaker, N.; Bosch, T.; Deursen, J. van

    2006-01-01

    A negative aspect of serial flow production systems is its lack of flexibility. Other production systems like the flexing flow and the shopping system are more flexible as the number of workers can be easily adjusted to temporal demands. But how efficient are these flexible systems? In a laboratory

  19. Recent advances in flexible and wearable organic optoelectronic devices

    Science.gov (United States)

    Zhu, Hong; Shen, Yang; Li, Yanqing; Tang, Jianxin

    2018-01-01

    Flexible and wearable optoelectronic devices have been developing to a new stage due to their unique capacity for the possibility of a variety of wearable intelligent electronics, including bendable smartphones, foldable touch screens and antennas, paper-like displays, and curved and flexible solid-state lighting devices. Before extensive commercial applications, some issues still have to be solved for flexible and wearable optoelectronic devices. In this regard, this review concludes the newly emerging flexible substrate materials, transparent conductive electrodes, device architectures and light manipulation methods. Examples of these components applied for various kinds of devices are also summarized. Finally, perspectives about the bright future of flexible and wearable electronic devices are proposed. Project supported by the Ministry of Science and Technology of China (No. 2016YFB0400700).

  20. Static inelastic analysis of steel frames with flexible connections

    Directory of Open Access Journals (Sweden)

    Nefovska-Danilović M.

    2004-01-01

    Full Text Available The effects of connection flexibility and material yielding on the behavior of plane steel frames subjected to static (monotonic loads are presented in this paper. Two types of material nonlinearities are considered: flexible nodal connections and material yielding, as well as geometric nonlinearity of the structure. To account for material yielding, a plastic hinge concept is adopted. A flexible connection is idealized by nonlinear rotational spring. Plastic hinge is also idealized by nonlinear rotational spring attached in series with the rotational spring that accounts for connection flexibility. The stiffness matrix for the beam with flexible connections and plastic hinges at its ends is obtained. To illustrate the validity and accuracy of the proposed numerical model, several examples have been conducted.