WorldWideScience

Sample records for thermal-optical transmittance tot

  1. Evaluation of thermal optical analysis method of elemental carbon for marine fuel exhaust.

    Science.gov (United States)

    Lappi, Maija K; Ristimäki, Jyrki M

    2017-12-01

    The awareness of black carbon (BC) as the second largest anthropogenic contributor in global warming and an ice melting enhancer has increased. Due to prospected increase in shipping especially in the Arctic reliability of BC emissions and their invented amounts from ships is gaining more attention. The International Maritime Organization (IMO) is actively working toward estimation of quantities and effects of BC especially in the Arctic. IMO has launched work toward constituting a definition for BC and agreeing appropriate methods for its determination from shipping emission sources. In our study we evaluated the suitability of elemental carbon (EC) analysis by a thermal-optical transmittance (TOT) method to marine exhausts and possible measures to overcome the analysis interferences related to the chemically complex emissions. The measures included drying with CaSO 4, evaporation at 40-180ºC, H 2 O treatment, and variation of the sampling method (in-stack and diluted) and its parameters (e.g., dilution ratio, Dr). A reevaluation of the nominal organic carbon (OC)/EC split point was made. Measurement of residual carbon after solvent extraction (TC-C SOF ) was used as a reference, and later also filter smoke number (FSN) measurement, which is dealt with in a forthcoming paper by the authors. Exhaust sources used for collecting the particle sample were mainly four-stroke marine engines operated with variable loads and marine fuels ranging from light to heavy fuel oils (LFO and HFO) with a sulfur content range of carbon (PyC) from OC, affecting the accuracy of EC determination. Thus, uncertainty remained regarding the EC results from HFO fuels. The work supports one part of the decision making in black carbon (BC) determination methodology. If regulations regarding BC emissions from marine engines will be implemented in the future, a well-defined and at best unequivocal method of BC determination is required for coherent and comparable emission inventories and

  2. Evaluatie Dam tot Damloop 2014

    NARCIS (Netherlands)

    Deutekom-Baart de la Faille, Marije

    In het weekend van 20 en 21 september 2014 vond de 30ste editie van de Dam tot Damloop plaats. Onderzoekers van de Hogeschool van Amsterdam en Hogeschool Inholland hebben bij de Dam tot Damloop een evaluatieonderzoek uitgevoerd met als doel het vinden van aanknopingspunten voor het structureel

  3. Mogelijkheden tot productie van beertjes

    NARCIS (Netherlands)

    Scholten, R.; Huiskes, J.

    1994-01-01

    In opdracht van het Produktschap Vee en Vlees is het project Mogelijkheden tot productie van vleesbeertjes en afzet van vlees en vleesproducten hiervan uitgevoerd. De afzetmogelijkheden voor vlees van beertjes zijn en blijven vooralsnog minimaal

  4. Synthesis, spectral, thermal, optical dispersion and dielectric ...

    Indian Academy of Sciences (India)

    2016-08-26

    Aug 26, 2016 ... ... fast atom bombardment-mass spectrometry, thermogravimetric/ differential thermal analysis, and ... In UV spectrum, the transmittance increases followed by a sharp decrease at wavelength 700–750 nm within visible range.

  5. Safe Anesthesia For Every Tot

    DEFF Research Database (Denmark)

    Weiss, Markus; Vutskits, Laszlo; Hansen, Tom G

    2015-01-01

    PURPOSE OF REVIEW: The term 'safe use of anesthesia in children is ill-defined and requires definition of and focus on the 'safe conduct of pediatric anesthesia'. RECENT FINDINGS: The Safe Anesthesia For Every Tot initiative (www.safetots.org) has been set up during the last year to focus...... on the safe conduct of pediatric anesthesia. This initiative aims to provide guidance on markers of quality anesthesia care. The introduction and implementation of national regulations of 'who, where, when and how' are required and will result in an improved perioperative outcome in vulnerable children....... The improvement of teaching, training, education and supervision of the safe conduct of pediatric anesthesia are the main goals of the safetots.org initiative. SUMMARY: This initiative addresses the well known perioperative risks in young children, perioperative causes for cerebral morbidity as well as gaps...

  6. Landbouwprotectie als middel tot politieke integratie.

    NARCIS (Netherlands)

    Noort, van den P.C.

    1988-01-01

    In acht hoofdstukken is dit beleid uiteengezet. 1. Landbouwprotectie als middel tot politieke integratie. 2. Eigenbelang van een meer marktgericht landbouwbeleid. 3. uitdagingen voor landbouwcooperaties. 4. Het westers landbouwbeleid en het wereldvoedselprobleem. 5. Landbouw heeft nu een eigen

  7. Dam tot damloop : economische en maatschappelijke waarde

    NARCIS (Netherlands)

    de Nooij, Michiel; Horsselenberg, Peter

    2014-01-01

    Ruim 36.757 lopers (op de hoofdafstand!) en 115.000 bezoekers langs het parcours van het centrum van Amsterdam naar het centrum van Zaanstad, maakt de Dam tot damloop een groot evenement (het grootste hardloop evenement van Nederland) met een flinke impact op de (lokale) samenleving en economie. Dit

  8. 'n Redaksionele voonvoord tot die Hervorrade Teologiese Studies ...

    African Journals Online (AJOL)

    Hy is nie net 'n geëerde oud-redaksielid nie, maar was self vanaf 1957 tot 1971 verantwoordelik vir die versorging van die tydskrif en het ook vanaf 1982 tot 1985 as redaksiesekretaris opgetree. Hierbenewens is prof Pont dié medewerker wat verreweg die meeste artikels in HTS laat publiseer het, te wete ses en sestig tot ...

  9. Dynamic nonlinear thermal optical effects in coupled ring resonators

    Directory of Open Access Journals (Sweden)

    Chenguang Huang

    2012-09-01

    Full Text Available We investigate the dynamic nonlinear thermal optical effects in a photonic system of two coupled ring resonators. A bus waveguide is used to couple light in and out of one of the coupled resonators. Based on the coupling from the bus to the resonator, the coupling between the resonators and the intrinsic loss of each individual resonator, the system transmission spectrum can be classified by three different categories: coupled-resonator-induced absorption, coupled-resonator-induced transparency and over coupled resonance splitting. Dynamic thermal optical effects due to linear absorption have been analyzed for each category as a function of the input power. The heat power in each resonator determines the thermal dynamics in this coupled resonator system. Multiple “shark fins” and power competition between resonators can be foreseen. Also, the nonlinear absorption induced thermal effects have been discussed.

  10. TVT versus TOT, 2-year prospective randomized study.

    Science.gov (United States)

    Wadie, Bassem S; El-Hefnawy, Ahmed S; Elhefnawy, Ahmed S

    2013-06-01

    To evaluate in a comprehensive way TVT in comparison with TOT, the results of a single-center RCT are presented. Many studies addressed efficacy and safety of TVT and TOT. Women included were adults having predominant SUI with positive stress test. They were randomized to get either TVT (Gynecare(®)) or TOT (Aris(®)). All women were seen 1 week, 3, 6, 12, 18, and 24 months. Seventy-one women completed 2-year follow-up. Median age was 47 (range 33-60 years). Mean ± SD BMI in TVT group was 34 ± 5 while in TOT group was 32 ± 5 kg/m(2). POP of any degree was seen in 50 % (35 women). At 1 year, pad test-negative women were 31 and 29 for TVT and TOT, respectively. At 2 years, figures became 28 in TVT group and 27 in TOT. At 1 year, UDI 6 and IIQ 7 decreased by 78.5 and 81 % for TVT and by 69 % and 75 % for TOT group. At 2 year, comparable percentages were 73 and 79 % for TVT and 69 and 82 % for TOT. Fifteen unique patients had adverse events, 10 of them had TOT. Both tapes have similar efficacy, regarding cure of incontinence. TVT is more effective, albeit insignificantly, than TOT at 2 years. However, serious adverse events were more frequent with TVT, yet TOT has more unique adverse events.

  11. Thermal/optical methods for elemental carbon quantification in soils and urban dusts: equivalence of different analysis protocols.

    Directory of Open Access Journals (Sweden)

    Yongming Han

    Full Text Available Quantifying elemental carbon (EC content in geological samples is challenging due to interferences of crustal, salt, and organic material. Thermal/optical analysis, combined with acid pretreatment, represents a feasible approach. However, the consistency of various thermal/optical analysis protocols for this type of samples has never been examined. In this study, urban street dust and soil samples from Baoji, China were pretreated with acids and analyzed with four thermal/optical protocols to investigate how analytical conditions and optical correction affect EC measurement. The EC values measured with reflectance correction (ECR were found always higher and less sensitive to temperature program than the EC values measured with transmittance correction (ECT. A high-temperature method with extended heating times (STN120 showed the highest ECT/ECR ratio (0.86 while a low-temperature protocol (IMPROVE-550, with heating time adjusted for sample loading, showed the lowest (0.53. STN ECT was higher than IMPROVE ECT, in contrast to results from aerosol samples. A higher peak inert-mode temperature and extended heating times can elevate ECT/ECR ratios for pretreated geological samples by promoting pyrolyzed organic carbon (PyOC removal over EC under trace levels of oxygen. Considering that PyOC within filter increases ECR while decreases ECT from the actual EC levels, simultaneous ECR and ECT measurements would constrain the range of EC loading and provide information on method performance. Further testing with standard reference materials of common environmental matrices supports the findings. Char and soot fractions of EC can be further separated using the IMPROVE protocol. The char/soot ratio was lower in street dusts (2.2 on average than in soils (5.2 on average, most likely reflecting motor vehicle emissions. The soot concentrations agreed with EC from CTO-375, a pure thermal method.

  12. Thermal/optical methods for elemental carbon quantification in soils and urban dusts: equivalence of different analysis protocols.

    Science.gov (United States)

    Han, Yongming; Chen, Antony; Cao, Junji; Fung, Kochy; Ho, Fai; Yan, Beizhan; Zhan, Changlin; Liu, Suixin; Wei, Chong; An, Zhisheng

    2013-01-01

    Quantifying elemental carbon (EC) content in geological samples is challenging due to interferences of crustal, salt, and organic material. Thermal/optical analysis, combined with acid pretreatment, represents a feasible approach. However, the consistency of various thermal/optical analysis protocols for this type of samples has never been examined. In this study, urban street dust and soil samples from Baoji, China were pretreated with acids and analyzed with four thermal/optical protocols to investigate how analytical conditions and optical correction affect EC measurement. The EC values measured with reflectance correction (ECR) were found always higher and less sensitive to temperature program than the EC values measured with transmittance correction (ECT). A high-temperature method with extended heating times (STN120) showed the highest ECT/ECR ratio (0.86) while a low-temperature protocol (IMPROVE-550), with heating time adjusted for sample loading, showed the lowest (0.53). STN ECT was higher than IMPROVE ECT, in contrast to results from aerosol samples. A higher peak inert-mode temperature and extended heating times can elevate ECT/ECR ratios for pretreated geological samples by promoting pyrolyzed organic carbon (PyOC) removal over EC under trace levels of oxygen. Considering that PyOC within filter increases ECR while decreases ECT from the actual EC levels, simultaneous ECR and ECT measurements would constrain the range of EC loading and provide information on method performance. Further testing with standard reference materials of common environmental matrices supports the findings. Char and soot fractions of EC can be further separated using the IMPROVE protocol. The char/soot ratio was lower in street dusts (2.2 on average) than in soils (5.2 on average), most likely reflecting motor vehicle emissions. The soot concentrations agreed with EC from CTO-375, a pure thermal method.

  13. Borehole induction coil transmitter

    Science.gov (United States)

    Holladay, Gale; Wilt, Michael J.

    2002-01-01

    A borehole induction coil transmitter which is a part of a cross-borehole electromagnetic field system that is used for underground imaging applications. The transmitter consists of four major parts: 1) a wound ferrite or mu-metal core, 2) an array of tuning capacitors, 3) a current driver circuit board, and 4) a flux monitor. The core is wound with several hundred turns of wire and connected in series with the capacitor array, to produce a tuned coil. This tuned coil uses internal circuitry to generate sinusoidal signals that are transmitted through the earth to a receiver coil in another borehole. The transmitter can operate at frequencies from 1-200 kHz and supplies sufficient power to permit the field system to operate in boreholes separated by up to 400 meters.

  14. Laser transmitter system

    International Nuclear Information System (INIS)

    Dye, R.A.

    1975-01-01

    A laser transmitter system is disclosed which utilizes mechanical energy for generating an output pulse. The laser system includes a current developing device such as a piezoelectric crystal which charges a storage device such as a capacitor in response to a mechanical input signal. The capacitor is coupled to a switching device, such as a silicon controlled rectifier (SCR). The switching device is coupled to a laser transmitter such as a GaAs laser diode, which provides an output signal in response to the capacitor being discharged

  15. Mediaplanning : Van marketingcommunicatieplan tot mediaplanning en –inkoop

    NARCIS (Netherlands)

    Babs van Teylingen-Geerlings

    2010-01-01

    Het boek Mediaplanning verschaft snel inzicht in het gehele mediaplanningsproces: van mediabriefing, het selecteren van de mediumtypen aan de hand van de mediumbeoordelingscriteria, media- en planningsschema, budgetverdeling tot media-inkoop. Kennis van het mediaplanningsproces alleen is echter niet

  16. AKSIE: BEESVLEISPRODUKSIE TOT DIE JAAR 2OO3

    African Journals Online (AJOL)

    comminuted meats"' . Komponente van die lyfde kwart sal verbruikers- waarde kry. o verpakking en aanbieding sal meer gesofistikeerd moet wees om doeltreffende rakleeftyd en higiene te verseker en die verbruiker meer geleentheid tot ondersoek ...

  17. E-business your business : van website tot strategie

    NARCIS (Netherlands)

    drs Boudewijn Raessens

    2007-01-01

    Informatie- en communicatietechnologie (ICT) is doorgedrongen tot alle niveaus van de economie en samenleving. Bestaande grenzen tussen markten, bedrijven en consumenten worden opengebroken en nieuwe producten en diensten zijn steeds sneller, slimmer en goedkoper beschikbaar voor grote groepen

  18. TOT phenomena: Gesture production in younger and older adults.

    Science.gov (United States)

    Theocharopoulou, Foteini; Cocks, Naomi; Pring, Timothy; Dipper, Lucy T

    2015-06-01

    This study explored age-related changes in gesture to better understand the relationship between gesture and word retrieval from memory. The frequency of gestures during tip-of-the-tongue (TOT) states highlights this relationship. There is a lack of evidence describing the form and content of iconic gestures arising spontaneously in such TOT states and a parallel gap addressing age-related variations. In this study, TOT states were induced in 45 participants from 2 age groups (older and younger adults) using a pseudoword paradigm. The type and frequency of gestures produced was recorded during 2 experimental conditions (single-word retrieval and narrative task). We found that both groups experienced a high number of TOT states, during which they gestured. Iconic co-TOT gestures were more common than noniconic gestures. Although there was no age effect on the type of gestures produced, there was a significant, task-specific age difference in the amount of gesturing. That is, younger adults gestured more in the narrative task, whereas older adults generated more gestures in the single-word-retrieval task. Task-specific age differences suggest that there are age-related differences in terms of the cognitive operations involved in TOT gesture production. (c) 2015 APA, all rights reserved.

  19. Predicting ambient aerosol Thermal Optical Reflectance (TOR) measurements from infrared spectra: organic carbon

    Science.gov (United States)

    Dillner, A. M.; Takahama, S.

    2014-11-01

    Organic carbon (OC) can constitute 50% or more of the mass of atmospheric particulate matter. Typically, the organic carbon concentration is measured using thermal methods such as Thermal-Optical Reflectance (TOR) from quartz fiber filters. Here, methods are presented whereby Fourier Transform Infrared (FT-IR) absorbance spectra from polytetrafluoroethylene (PTFE or Teflon) filters are used to accurately predict TOR OC. Transmittance FT-IR analysis is rapid, inexpensive, and non-destructive to the PTFE filters. To develop and test the method, FT-IR absorbance spectra are obtained from 794 samples from seven Interagency Monitoring of PROtected Visual Environment (IMPROVE) sites sampled during 2011. Partial least squares regression is used to calibrate sample FT-IR absorbance spectra to artifact-corrected TOR OC. The FTIR spectra are divided into calibration and test sets by sampling site and date which leads to precise and accurate OC predictions by FT-IR as indicated by high coefficient of determination (R2; 0.96), low bias (0.02 μg m-3, all μg m-3 values based on the nominal IMPROVE sample volume of 32.8 m-3), low error (0.08 μg m-3) and low normalized error (11%). These performance metrics can be achieved with various degrees of spectral pretreatment (e.g., including or excluding substrate contributions to the absorbances) and are comparable in precision and accuracy to collocated TOR measurements. FT-IR spectra are also divided into calibration and test sets by OC mass and by OM / OC which reflects the organic composition of the particulate matter and is obtained from organic functional group composition; this division also leads to precise and accurate OC predictions. Low OC concentrations have higher bias and normalized error due to TOR analytical errors and artifact correction errors, not due to the range of OC mass of the samples in the calibration set. However, samples with low OC mass can be used to predict samples with high OC mass indicating that the

  20. Factorial-based response-surface modeling with confidence intervals for optimizing thermal-optical transmission analysis of atmospheric black carbon

    International Nuclear Information System (INIS)

    Conny, J.M.; Norris, G.A.; Gould, T.R.

    2009-01-01

    Thermal-optical transmission (TOT) analysis measures black carbon (BC) in atmospheric aerosol on a fibrous filter. The method pyrolyzes organic carbon (OC) and employs laser light absorption to distinguish BC from the pyrolyzed OC; however, the instrument does not necessarily separate the two physically. In addition, a comprehensive temperature protocol for the analysis based on the Beer-Lambert Law remains elusive. Here, empirical response-surface modeling was used to show how the temperature protocol in TOT analysis can be modified to distinguish pyrolyzed OC from BC based on the Beer-Lambert Law. We determined the apparent specific absorption cross sections for pyrolyzed OC (σ Char ) and BC (σ BC ), which accounted for individual absorption enhancement effects within the filter. Response-surface models of these cross sections were derived from a three-factor central-composite factorial experimental design: temperature and duration of the high-temperature step in the helium phase, and the heating increase in the helium-oxygen phase. The response surface for σ BC , which varied with instrument conditions, revealed a ridge indicating the correct conditions for OC pyrolysis in helium. The intersection of the σ BC and σ Char surfaces indicated the conditions where the cross sections were equivalent, satisfying an important assumption upon which the method relies. 95% confidence interval surfaces defined a confidence region for a range of pyrolysis conditions. Analyses of wintertime samples from Seattle, WA revealed a temperature between 830 deg. C and 850 deg. C as most suitable for the helium high-temperature step lasting 150 s. However, a temperature as low as 750 deg. C could not be rejected statistically

  1. Linguistic Phenomena in Men and Women - TOT, FOK, Verbal Fluency

    OpenAIRE

    Ewa Szepietowska; Barbara Gawda; Agnieszka Gawda

    2013-01-01

    The aim of this study is to describe the differences between women and men in the phenomena of feeling of knowing/know (FOK), tip of the tongue (TOT), and verbal fluency. Two studies are presented. The first included a group of 60 participants and focused on the analysis of FOK and TOT in men and women. The second study described the performance of 302 participants in verbal fluency tasks. Both studies showed that sex is not a significant predictor of linguistic abilities. Rather, the main fa...

  2. 47 CFR 74.461 - Transmitter power.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Transmitter power. 74.461 Section 74.461....461 Transmitter power. (a) Transmitter power is the power at the transmitter output terminals and.... For the purpose of this Subpart, the transmitter power is the carrier power. (b) The authorized...

  3. Veeneiken - sleutel tot het verleden landschap en klimaat?

    NARCIS (Netherlands)

    Sass, U.G.W.

    2003-01-01

    Veeneiken zijn (veen)restanten van eiken uit moerasbossen op laagveen. Ze vormen interessant materiaal voor dendrochronologisch onderzoek. Er is voor deze eiken inmiddels een chronologie opgebouwd over de jaren 3600 BC tot 563 AD. Onderzoek aan veeneiken in Nederland en Noordwest-Europa en aan twee

  4. IN KRITIESE BESKOUING VAN INLEIDING TOT DIE SEMANTIEK

    African Journals Online (AJOL)

    Dit laat twee interpretasie- moontlikhede oop: "later" kan of beteken "later in Syntactic Structures. (Chomsky 1957)", of "tussen Syntactic Structures en Katz en Fodor (1963) se The Structure of a Semantic Theory". Laasgenoemde werk is naamlik die eerste wat deur De Klerk as deel van die tweede periode, "die aanloop tot.

  5. Universal tritium transmitter

    International Nuclear Information System (INIS)

    Cordaro, J. V.; Wood, M.

    2008-01-01

    sufficient time to thermally equilibrate. Amplifiers, transistors, resistors all need time to stabilize before the electrometer circuit will measure accurately in the 10 -15 and 10 -14 ampere range. Existing electrometers give the user no indication when the unit has stabilized and is acceptable for low level measurements. Savannah River National Laboratory (SRNL) funded through the NNSA Plant Directed Research and Development (PDRD) program, has developed a truly Universal Tritium Transmitter (UTT) capable of solving many known problems with existing commercial electrometers. This UTT pushes the state-of-the-art in electrometer design and incorporates solutions to deficiencies found in commercial electrometers. (authors)

  6. Predicting ambient aerosol thermal-optical reflectance measurements from infrared spectra: elemental carbon

    Science.gov (United States)

    Dillner, A. M.; Takahama, S.

    2015-10-01

    Elemental carbon (EC) is an important constituent of atmospheric particulate matter because it absorbs solar radiation influencing climate and visibility and it adversely affects human health. The EC measured by thermal methods such as thermal-optical reflectance (TOR) is operationally defined as the carbon that volatilizes from quartz filter samples at elevated temperatures in the presence of oxygen. Here, methods are presented to accurately predict TOR EC using Fourier transform infrared (FT-IR) absorbance spectra from atmospheric particulate matter collected on polytetrafluoroethylene (PTFE or Teflon) filters. This method is similar to the procedure developed for OC in prior work (Dillner and Takahama, 2015). Transmittance FT-IR analysis is rapid, inexpensive and nondestructive to the PTFE filter samples which are routinely collected for mass and elemental analysis in monitoring networks. FT-IR absorbance spectra are obtained from 794 filter samples from seven Interagency Monitoring of PROtected Visual Environment (IMPROVE) sites collected during 2011. Partial least squares regression is used to calibrate sample FT-IR absorbance spectra to collocated TOR EC measurements. The FT-IR spectra are divided into calibration and test sets. Two calibrations are developed: one developed from uniform distribution of samples across the EC mass range (Uniform EC) and one developed from a uniform distribution of Low EC mass samples (EC < 2.4 μg, Low Uniform EC). A hybrid approach which applies the Low EC calibration to Low EC samples and the Uniform EC calibration to all other samples is used to produce predictions for Low EC samples that have mean error on par with parallel TOR EC samples in the same mass range and an estimate of the minimum detection limit (MDL) that is on par with TOR EC MDL. For all samples, this hybrid approach leads to precise and accurate TOR EC predictions by FT-IR as indicated by high coefficient of determination (R2; 0.96), no bias (0.00 μg m-3, a

  7. Predicting ambient aerosol Thermal Optical Reflectance (TOR) measurements from infrared spectra: elemental carbon

    Science.gov (United States)

    Dillner, A. M.; Takahama, S.

    2015-06-01

    Elemental carbon (EC) is an important constituent of atmospheric particulate matter because it absorbs solar radiation influencing climate and visibility and it adversely affects human health. The EC measured by thermal methods such as Thermal-Optical Reflectance (TOR) is operationally defined as the carbon that volatilizes from quartz filter samples at elevated temperatures in the presence of oxygen. Here, methods are presented to accurately predict TOR EC using Fourier Transform Infrared (FT-IR) absorbance spectra from atmospheric particulate matter collected on polytetrafluoroethylene (PTFE or Teflon) filters. This method is similar to the procedure tested and developed for OC in prior work (Dillner and Takahama, 2015). Transmittance FT-IR analysis is rapid, inexpensive, and non-destructive to the PTFE filter samples which are routinely collected for mass and elemental analysis in monitoring networks. FT-IR absorbance spectra are obtained from 794 filter samples from seven Interagency Monitoring of PROtected Visual Environment (IMPROVE) sites collected during 2011. Partial least squares regression is used to calibrate sample FT-IR absorbance spectra to collocated TOR EC measurements. The FTIR spectra are divided into calibration and test sets. Two calibrations are developed, one which is developed from uniform distribution of samples across the EC mass range (Uniform EC) and one developed from a~uniform distribution of low EC mass samples (EC < 2.4 μg, Low Uniform EC). A hybrid approach which applies the low EC calibration to low EC samples and the Uniform EC calibration to all other samples is used to produces predictions for low EC samples that have mean error on par with parallel TOR EC samples in the same mass range and an estimate of the minimum detection limit (MDL) that is on par with TOR EC MDL. For all samples, this hybrid approach leads to precise and accurate TOR EC predictions by FT-IR as indicated by high coefficient of variation (R2; 0.96), no

  8. Training of Trainers (ToT) Program in Team Teaching

    Science.gov (United States)

    Febrianti, Werry; Wiryanto, Leo Hari

    2018-01-01

    The first year students in Sumatera Institute of Technology (ITERA) follow the first year program (TPB). They will learn about mathematics, physics, chemistry, and all of the basic subjects that they need for learning in ITERA. They will study in the big classrooms with different background department of their friends. This situation makes the lectures become more challenging in teaching their lessons. Besides the classrooms, the experience of the lecturers is still need to be improved because the lecturers are young and less of experience in teaching so that they need guidance from their senior lecturer. Because of that situation, Training of Trainers (ToT) program in team teaching is one of the solution that can increase the young lecturers’s ability so that they can teach well in the massal conditions of the classrooms. ToT program in team teaching indicated the better result than regular teaching.

  9. 47 CFR 80.959 - Radiotelephone transmitter.

    Science.gov (United States)

    2010-10-01

    ... watts into 50 ohms nominal resistance when operated with its rated supply voltage. The transmitter must... capability of the transmitter, measurements of primary supply voltage and transmitter output power must be... voltage measured at the power input terminals to the transmitter terminated in a matching artificial load...

  10. A study of time over threshold (TOT) technique for plastic scintillator counter

    International Nuclear Information System (INIS)

    Wu Jinjie; Chinese Academy of Sciences, Beijing; Heng Yuekun; Sun Zhijia; Wu Chong; Yang Guian; Jiang Chun Hua; Zhao Yuda

    2008-01-01

    A new charge measurement method, time over threshold (TOT), has been used in some gas detectors lately. Here TOT is studied for TOF system, made of plastic scintillator counter, which can simplify the electronics of the system. The signal characteristics are measured and analyzed with a high quality oscilloscope, including noise, pedestal, signal amplitude, total charge, rise time and the correlation between them. The TOT and charge are related and can be fitted by some empirical formula. The charge measurement resolution by TOT is given and this will help the design of TOF electronics. (authors)

  11. 47 CFR 101.807 - Transmitter power.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Transmitter power. 101.807 Section 101.807... SERVICES Local Television Transmission Service § 101.807 Transmitter power. Stations in this service will not be authorized to use transmitters having a rated power output in excess of the limits set forth in...

  12. 47 CFR 80.215 - Transmitter power.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Transmitter power. 80.215 Section 80.215... MARITIME SERVICES General Technical Standards § 80.215 Transmitter power. (a) Transmitter power shown on the radio station authorization is the maximum power the licensee is authorized to use. Power is...

  13. 47 CFR 101.513 - Transmitter power.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Transmitter power. 101.513 Section 101.513... SERVICES 24 GHz Service and Digital Electronic Message Service § 101.513 Transmitter power. The transmitter power will be governed by § 101.113. Further, each application must contain an analysis demonstrating...

  14. Monsternemingen van het grondwater tot vijf meter beneden de grondwaterspiegel - De selectie van kansrijke methoden

    NARCIS (Netherlands)

    Elzakker BG van; Gast LFL; LVM

    2006-01-01

    Er zijn drie mogelijk geschikte methoden geselecteerd om grondwatermonsters tot vijf meter beneden de grondwaterspiegel te verzamelen. Deze methoden worden nu verder in het veld getest om tot een aanbeveling te komen. Aanleiding voor de studie is dat volgens het concept monitorrichtsnoer

  15. Bijdrage tot de natuur- en Ontleedkundige Kennis van den Manatus Americanus

    NARCIS (Netherlands)

    Vrolik, W.

    1852-01-01

    Vreemd is het, maar intusschen door de geschiedenis der wetenschap steeds bevestigd, dat er enkele diersoorten zijn, hoewel niet bepaald tot de zeldzame behoorende, tot wier kennis men niet dan met groote moeite en als het ware stuksgewijze geraakt. Dat onder deze vooral de Lamantinen behooren, zal

  16. Female sexual function following a novel transobturator sling procedure without paraurethral dissection (modified-TOT

    Directory of Open Access Journals (Sweden)

    Burak Arslan

    Full Text Available ABSTRACT Purpose To determine whether there is a difference in sexual function after modified and classical TOT procedures. Materials and Methods Of the 80 sexually active women with SUI, 36 underwent an original outside-in TOT as described by Delorme, and 44 underwent modified TOT procedure, between 2011 and 2015. The severity of incontinence and sexual function were evaluated using International Consultation on Incontinence Questionnaire-Short Form (ICIQ-SF and Female Sexual Function Index (FSFI questionnaires preoperatively and 3 months after surgery. Results The postoperative ICIQ-SF score was significantly lower than the preoperative ICIQ-SF score in both groups (p=0.004 for modified TOT and p=0.002 for classical TOT. There was no significant difference in the ICIQ-SF score reduction between the two groups (14.1±2.1 vs. 14.4±1.9; p=0.892. Complication rates according to the Clavien-Dindo classification were also similar in both groups. In both groups, difference between preoperative and postoperative FSFI scores revealed a statistically significant improvement in all domains. Comparison of postoperative 3-month FSFI scores of modified and classical TOT groups showed statistically significant differences in arousal, lubrication and orgasm domains. Desire, satisfaction, pain and total FSFI scores did not differ significantly between two groups. Conclusion The modified TOT technique is a simple, reliable and minimal invasive procedure. The cure rate of incontinence and complication rates are the same as those of the classical TOT technique. However, due to the positive effects of minimal tissue damage on sexual arousal and orgasmic function, modified TOT has an advantage over the classical TOT.

  17. Gamma irradiation effects on the thermal, optical and structural properties of Cr-39 nuclear track detector

    International Nuclear Information System (INIS)

    Nouh, S.A.; Said, A.F.; Atta, M.R.; EL-Mellegy, W.M.; EL-Meniawi, S.

    2006-01-01

    A study of the effect of gamma irradiation on the thermal, optical and structural properties of CR-39 diglycol carbonate solid state nuclear track detector (SSNTD) has been carried out. Samples from CR-39 polymer were irradiated with gamma doses at levels between 20 and 300 KGy. Non-isothermal studies were carried out using thermo-gravimetry (TG), differential thermo-gravimetry (DTG) and differential thermal analysis (DTA) to obtain the activation energy of decomposition and the transition temperatures for the non-irradiated and irradiated CR-39 samples. In addition, optical and structural property studies were performed on non-irradiated and irradiated CR-39 samples using refractive index and X-ray diffraction measurements. The variation of onset temperature of decomposition (To) thermal activation energy of decomposition (Ea) melting temperature (Tm) refractive index (n) and the mass fraction of the amorphous phase with the gamma dose were studied. It was found that many changes in the thermal, optical and structural properties of the CR-39 polymer could be produced by gamma irradiation via the degradation and cross linking mechanisms. Also, the gamma dose gave an advantage for increasing the correlation between the thermal stability of CR-39 polymer and the bond formation created by the ionizing effect of gamma radiation

  18. Thermal, optical, and dielectric properties of fluoride Rb2TaF7

    Science.gov (United States)

    Pogorel'tsev, E. I.; Mel'nikova, S. V.; Kartashev, A. V.; Gorev, M. V.; Flerov, I. N.; Laptash, N. M.

    2017-05-01

    The thermal, optical, and dielectric properties of fluoride Rb2TaF7 were investigated. It was observed that the variation in chemical pressure in fluorides A 2 +TaF7 caused by the cation substitution of rubidium for ammonium does not affect the ferroelastic nature of structural distortions, but leads to stabilization of the high- and low-temperature phases and enhancement of birefringence. The entropy of the phase transition P4/nmm ↔ Cmma is typical of the shift transformations, which is consistent with a model of the initial and distorted phase structures. The anisotropy of chemical pressure causes the change of signs of the anomalous strain and baric coefficient dT/ dp of Rb2TaF7 as compared with the values for its ammonium analog.

  19. 47 CFR 101.129 - Transmitter location.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Transmitter location. 101.129 Section 101.129... SERVICES Technical Standards § 101.129 Transmitter location. (a) The applicant must determine, prior to... adequate to render the service proposed. In cases of questionable antenna locations, it is desirable to...

  20. 47 CFR 90.215 - Transmitter measurements.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Transmitter measurements. 90.215 Section 90.215... MOBILE RADIO SERVICES General Technical Standards § 90.215 Transmitter measurements. (a) The licensee of... current station authorization. On authorizations stating only the input power to the final radiofrequency...

  1. Gewenst beleid tegen ongewenst gedrag : onveiligheid binnen de organisatie kan leiden tot ziekteverzuim

    NARCIS (Netherlands)

    Dalen, E.J. van; Nuyens, M.

    2005-01-01

    Indimidatie en agressie en geweld op het werk kunnen leiden tot gevoelens van onveiligheid en ziekteverzuim. Bepalingen in de Arbowet hebben onvoldoende effect op beleidsvorming ter voorkoming van ongewenste omgangsvormen. Goede praktijkvoorbeelden van beleid tegen ongewenst gedrag kunnen

  2. Second Question How Did this Shift in ToT Come About?

    Indian Academy of Sciences (India)

    Notes: Moving on on factors behind this shift in ToT, the last on my list: Surge in rural wages as a result of the massive rural employment guarantee scheme started by the Government in 2006. Turn for Chart.

  3. Perturbative corrections to sigma sub(tot) (e+e- -> hadrons) in supersymmetric QCD

    International Nuclear Information System (INIS)

    Kataev, A.L.; Pivovarov, A.A.

    1983-11-01

    sigmasub(tot) (e + e - -> γsup(*) -> hadrons) have been calculated in QCD at two-loop level. Three-loop corrections due to gluon pair production are quoted accompanied by quark-antiquark two-jet events. (orig.)

  4. An injectable acoustic transmitter for juvenile salmon

    Science.gov (United States)

    Deng, Z. D.; Carlson, T. J.; Li, H.; Xiao, J.; Myjak, M. J.; Lu, J.; Martinez, J. J.; Woodley, C. M.; Weiland, M. A.; Eppard, M. B.

    2015-01-01

    Salmon recovery and the potential detrimental effects of dams on fish have been attracting national attention due to the environmental and economic implications. In recent years acoustic telemetry has been the primary method for studying salmon passage. However, the size of the existing transmitters limits the minimum size of fish that can be studied, introducing a bias to the study results. We developed the first acoustic fish transmitter that can be implanted by injection instead of surgery. The new injectable transmitter lasts four times longer and weighs 30% less than other transmitters. Because the new transmitter costs significantly less to use and may substantially reduce adverse effects of implantation and tag burden, it will allow for study of migration behavior and survival of species and sizes of fish that have never been studied before. The new technology will lead to critical information needed for salmon recovery and the development of fish-friendly hydroelectric systems.

  5. Comparison Between Elemental Carbon Measured Using Thermal-Optical Analysis and Black Carbon Measurements Using A Novel Cellphone-Based System

    Science.gov (United States)

    Ramanathan, N.; Khan, B.; Leong, I.; Lukac, M.

    2011-12-01

    Black carbon (BC) is produced through the incomplete combustion of fossil and solid fuels. Current BC emissions inventories have large uncertainties of factors of 2 or more due to sparse measurements and because BC is often emitted by local sources that vary over time and space (Bond et al, 2004). Those uncertainties are major sources of error in air pollution models. Emissions from a variety of improved cookstove/fuel/combustion conditions were collected on pre-conditioned 47 mm quartz-fiber filters and analyzed for organic carbon (OC) and elemental carbon (EC) using thermal-optical analysis (TOA). The samples were then analyzed for BC concentration by using cellphone-based instrumentation developed by Ramanathan et al., 2011. The cellphone-based monitoring system (CBMS) is a wireless, low-cost, low-power system that monitors BC emissions. The CBMS is comprised of an aerosol filter sampler containing a battery-powered air pump and a 25mm filter holder that draws air in through a quartz-fiber filter. As black carbon deposits increase, the filter darkens--the darkest color representing the highest loading. A cellphone photograph of the filter with the black carbon deposit is taken and relayed to an analytics unit for comparison to a reference scale to estimate airborne BC concentration. The BC concentration can then be compared to the thermally derived EC concentration. TOA was conducted on a Sunset Laboratory Dual Optics Carbon Analyzer using a modified version of the Birch and Cary (1996) NIOSH 5040 protocol. The dual-optical instrument permitted simultaneous monitoring of the transmission (TOT) and reflectance (TOR). 619 samples were collected; EC was obtained using NIOSH TOT and NIOSH TOR methods, and BC was obtained using the CBMS analytics unit. The mean BC value reported by the CBMS agrees within 20% of the reference values for EC, confirming the findings in Ramanathan et al. (2011) based on samples from India. Given this accuracy, we conclude that the CBMS

  6. Comparison of TOT and TVT in Treatment of Female Stress Urinary Incontinence

    Directory of Open Access Journals (Sweden)

    Taylan Mit

    2014-03-01

    Full Text Available Aim: To compare the continence results and complications of the tension-free vaginal tape (TVT and transobturator tape (TOT procedures. Material and Method: Sixty two urinary incontinence patients; (37 were stress urinary incontinence and 25 were mixed incontinence underwent TVT or TOT. The clinic-pathologic parameters of the patients, perioperative and postoperative complications and outcome in terms of continence and quality of life were compared. Results: TOT and TVT were performed on % 50 of the patients respectively. An objective cure rate in patients who underwent TOT was observed in 74% of cases, an objective improvement in 26% of cases. 11 of the patients had dysuria, 10 of them had suprapubic pain. An objective cure rate in patients who underwent TVT was observed in 90% of cases, an objective improvement in 8% of cases. A de novo urge incontinence presented in 2 patients. The quality of life improved in 93,5% of cases. In terms of continence results and quality of life, there was no significant difference between the procedures. The complication rate was higher with the TVT procedure when compared to that of the TOT procedure. Discussion: TOT procedure in short terms, performs similar operational success with the TVT procedure. Operational time; in consideration of the cystoscopy time, can be an advantage compared to the TVT procedure. If the operation includes anterior colporrhaphy, the success of both procedures reduces.

  7. Opportunistic transmitter selection for selfless overlay cognitive radios

    KAUST Repository

    Shaqfeh, Mohammad; Zafar, Ammar; Alnuweiri, Hussein M.; Alouini, Mohamed-Slim

    2013-01-01

    We propose an opportunistic strategy to grant channel access to the primary and secondary transmitters in causal selfless overlay cognitive radios over block-fading channels. The secondary transmitter helps the primary transmitter by relaying

  8. TWT transmitter fault prediction based on ANFIS

    Science.gov (United States)

    Li, Mengyan; Li, Junshan; Li, Shuangshuang; Wang, Wenqing; Li, Fen

    2017-11-01

    Fault prediction is an important component of health management, and plays an important role in the reliability guarantee of complex electronic equipments. Transmitter is a unit with high failure rate. The cathode performance of TWT is a common fault of transmitter. In this dissertation, a model based on a set of key parameters of TWT is proposed. By choosing proper parameters and applying adaptive neural network training model, this method, combined with analytic hierarchy process (AHP), has a certain reference value for the overall health judgment of TWT transmitters.

  9. NRL transmittance measurements at DIRT-III

    Science.gov (United States)

    Curcio, J. A.; Haught, K. M.; Woytko, M. A.; Gott, C.

    1981-06-01

    This is a final report on NRL experiments at the DIRT-III tests at Fort Polk, Louisiana in April - May 1980. Spectral transmission data at 3 wavelengths 0.55 microns, 1.06 microns and 10.4 microns is reported for 27 events in natural soil and various prepared soils. Spectral transmittance of smoke and dust clouds generated by explosive charges was found to be independent of wavelengths in about 50% of the events where useful data was obtained. When the charge was buried in wet natural soil transmittance at 10.4 microns was transmittance at 0.55 microns .

  10. [TVT and TOT for surgical correction of female stress urinary incontinence. Comparison between techniques].

    Science.gov (United States)

    Torres Zambrano, G; Lujan Galán, M; Martín García, C; García Tello, A; Rodríguez García, N; Berenguer Sánchez, A

    2008-10-01

    Retrospective analysis of a series of patients with stress urinary incontinence that underwent surgery in our department, by means of the TVT and TOT techniques. We evaluate post operative continence, considering "cured" the patient with complete continence and "failure" any type of involuntary stress urine leak, independently of its severity registering the time of its appearance. For this purpose we used the Kaplan-Meier analysis comparing both techniques with the Breslow test. Additionally, postoperative complications were evaluated. 128 patients who underwent surgery by TVT (69 patients, 53.9%) and TOT (59 patients, 46.1%). Mean age was 54.4 years for TVT (95% CI 52.0-56.8) and 59 years for TOT (95% CI 55.9-62.1). Mean follow-up time was 18.7 months for TVT (95% CI 15.6-21.9) and 7.4 months for TOT (95% CI 5.8-8.9). Overall continence rate was 86.7%, 88.4% for TVT and 84.7% for TOT The probability of being continent six months after surgery was 89.1% for TVT and 78.2% for TOT (no significant differences, p = 0.31), with almost all failures within the first six months after surgery. TVT was more frecuently associated with urgency symptoms (33.3%, p = 0.001) and urge incontinence (18.8%,p = 0.16), urinary retention (11.6%, p = 0.38), and prevesical hematoma requiring mesh retrieval. Greater post operative pain was observed with TOT (20.3%, p = 0.005). Our results evidence a similar efficacy with both techniques, with the failures appearing over the first months after surgery. Complications of the voiding urgency type are significantly more frequent with TVT.

  11. Light transmittance under diffuse radiation circumstances

    International Nuclear Information System (INIS)

    Kieboom, A.M.G. van den; Stoffers, J.A.

    1985-01-01

    For a grower it is important to know the light transmittance of a greenhouse. With this date (and many others) he is able to make a decision about which greenhouse and covering is the most economical in his situation. It is absolute impossible for a grower to use figures that are functions of: • the orientation of the greenhouse, • the relation between direct and global radiation, • the amount of radiation, etc. • He needs one comparable figure. As a comparable figure for light transmittance of a greenhouse we use the transmittance factor that is estimated with a diffuse radiation source. This figure will be the same as the mean transmittance over one year for that greenhouse, even with extreme direct radiation and independent of the orientation of the greenhouse. (author)

  12. APMP Pilot Study on Transmittance Haze

    Science.gov (United States)

    Liu, Wen-Chun; Hwang, Jisoo; Koo, Annette; Wu, Houping; Leecharoen, Rojana; Yu, Hsueh-Ling

    2018-02-01

    Five NMIs within APMP, including CMS/ITRI, MSL, NIM, NIMT and KRISS from TCPR applied to the APMP technical committee initiative project for funding to carry out a pilot comparison of transmittance haze in 2012. The project started in 2014 and the final report was completed at the end of 2016. In this pilot comparison, three different haze standards were adopted, and transmittance haze for each standard was measured according to ASTM D1003 or ISO 14782. This paper presents the first results of an APMP pilot study of transmittance haze and the analysis of the variation among different haze measurement systems which are commonly used. The study shows that the variables such as sphere multiplier, transmittance distribution, fluorescence of samples and optical path of the incident beam cause discrepancies among NMIs and highlight deficiencies in current documentary standards.

  13. World War II Weather Record Transmittances

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — World War II Weather Record Transmittances are a record of the weather and meteorological data observed during World War II and transferred to the archive. It...

  14. Digital transmitter for data bus communications system

    Science.gov (United States)

    Proch, G. E. (Inventor)

    1975-01-01

    An improved digital transmitter for transmitting serial pulse code modulation (pcm) data at high bit rates over a transmission line is disclosed. When not transmitting, the transmitter features a high output impedance which prevents the transmitter from loading the transmission line. The pcm input is supplied to a logic control circuit which produces two discrete logic level signals which are supplied to an amplifier. The amplifier, which is transformer coupled to the output isolation circuitry, converts the discrete logic level signals to two high current level, ground isolated signals in the secondary windings of the coupling transformer. The latter signals are employed as inputs to the isolation circuitry which includes two series transistor pairs operating into a hybrid transformer functioning to isolate the transmitter circuitry from the transmission line.

  15. Terrestrial VLF transmitter injection into the magnetosphere

    Science.gov (United States)

    Cohen, M. B.; Inan, U. S.

    2012-08-01

    Very Low Frequency (VLF, 3-30 kHz) radio waves emitted from ground sources (transmitters and lightning) strongly impact the radiation belts, driving electron precipitation via whistler-electron gyroresonance, and contributing to the formation of the slot region. However, calculations of the global impacts of VLF waves are based on models of trans-ionospheric propagation to calculate the VLF energy reaching the magnetosphere. Limited comparisons of these models to individual satellite passes have found that the models may significantly (by >20 dB) overestimate amplitudes of ground based VLF transmitters in the magnetosphere. To form a much more complete empirical picture of VLF transmitter energy reaching the magnetosphere, we present observations of the radiation pattern from a number of ground-based VLF transmitters by averaging six years of data from the DEMETER satellite. We divide the slice at ˜700 km altitude above a transmitter into pixels and calculate the average field for all satellite passes through each pixel. There are enough data to see 25 km features in the radiation pattern, including the modal interference of the subionospheric signal mapped upwards. Using these data, we deduce the first empirical measure of the radiated power into the magnetosphere from these transmitters, for both daytime and nighttime, and at both the overhead and geomagnetically conjugate region. We find no detectable variation of signal intensity with geomagnetic conditions at low and mid latitudes (L ionospheric heating by one VLF transmitter which modifies the trans-ionospheric absorption of signals from other transmitters passing through the heated region.

  16. Tension free vaginal tape (TVT) vs Transobturator tape (TOT) complications and outcomes.

    Science.gov (United States)

    Potić, Milan; Ignjatović, Ivan; Bašić, Dragoslav

    2014-01-01

    Stress urinary incontinence (SUI) is managed with both TVT and TOT. The TVT route of placement could result in a higher com-plication rate. The aim of this study is to analyze and compare outcomes and complications of TVT and TOT in SUI treatment. Prospective study in 64 women with isolated SUI was validated through Urogenital Distress Inventory (UDI-6), Incontinence Impact questionnaire (IIQ-7) and International Continence Impact Questionnaire (ICIQ5-SF). Intraoperative and postoperative complications were noted. Patients were considered cured when negative on stress test and with no need for additional surgery during follow up, after one and three months. The cure rates for both TVT 26/30 (86,6%) and TOT 30/34 (88,2) were comparable. Higher rates of bleeding, bladder perforations, pain and dyspareunia are recorded in TVT group. Quality of life graded on the questionnaire basis proved significant improvement in both procedures. Both TVT and TOT have comparable cure results in the treatment of SUI. The TOT is equally effective in the SUI treatment with significantly lower complication incidence.

  17. Direct RF modulation transmitter, sampling clock frequency setting method for direct RF modulation transmitter

    NARCIS (Netherlands)

    Fukuda, Shuichi; Nauta, Bram

    2013-01-01

    PROBLEM TO BE SOLVED: To provide a direct RF modulation transmitter capable of satisfying a radiation level regulation even without providing a SAW filter. SOLUTION: A direct RF modulation transmitter includes: digital/RF converters 105, 106 to which an I digital baseband signal, a Q digital

  18. Direct RF modulation transmitter, sampling clock frequency setting method for direct RF modulation transmitter

    NARCIS (Netherlands)

    Fukuda, Shuichi; Nauta, Bram

    2014-01-01

    PROBLEM TO BE SOLVED: To provide a direct RF modulation transmitter capable of satisfying a radiation level regulation even without providing a SAW filter. SOLUTION: A direct RF modulation transmitter includes: digital/RF converters 105, 106 to which an I digital baseband signal, a Q digital

  19. Oil. From mineral resource treasure to resource plague; Olie. Van bodemschat tot grondstofvloek

    Energy Technology Data Exchange (ETDEWEB)

    Cabezas, M. [Divisie Financiele Stabiliteit, De Nederlandsche Bank, Amsterdam (Netherlands)

    2006-12-01

    Rising oil prices in the seventies resulted, also because of overspending, in disappointing economic development in the oil-producing countries. Although policy reactions to the current rise of the oil prices did not have that effect so far, there is the danger for financial instability. [Dutch] De olieprijsstijgingen in de jaren zeventig leidden door overbesteding tot tegenvallende economische prestaties bij veel olieproducerende landen. De beleidsreacties op de recente olieprijsstijging zijn tot dusverre hoopgevend, maar desondanks liggen er gevaren voor de financiele stabiliteit op de Ioer.

  20. Development and implementation of a generic analysis template for structural-thermal-optical-performance modeling

    Science.gov (United States)

    Scola, Salvatore; Stavely, Rebecca; Jackson, Trevor; Boyer, Charlie; Osmundsen, Jim; Turczynski, Craig; Stimson, Chad

    2016-09-01

    Performance-related effects of system level temperature changes can be a key consideration in the design of many types of optical instruments. This is especially true for space-based imagers, which may require complex thermal control systems to maintain alignment of the optical components. Structural-Thermal-Optical-Performance (STOP) analysis is a multi-disciplinary process that can be used to assess the performance of these optical systems when subjected to the expected design environment. This type of analysis can be very time consuming, which makes it difficult to use as a trade study tool early in the project life cycle. In many cases, only one or two iterations can be performed over the course of a project. This limits the design space to best practices since it may be too difficult, or take too long, to test new concepts analytically. In order to overcome this challenge, automation, and a standard procedure for performing these studies is essential. A methodology was developed within the framework of the Comet software tool that captures the basic inputs, outputs, and processes used in most STOP analyses. This resulted in a generic, reusable analysis template that can be used for design trades for a variety of optical systems. The template captures much of the upfront setup such as meshing, boundary conditions, data transfer, naming conventions, and post-processing, and therefore saves time for each subsequent project. A description of the methodology and the analysis template is presented, and results are described for a simple telescope optical system.

  1. Development and Implementation of a Generic Analysis Template for Structural-Thermal-Optical-Performance Modeling

    Science.gov (United States)

    Scola, Salvatore; Stavely, Rebecca; Jackson, Trevor; Boyer, Charlie; Osmundsen, Jim; Turczynski, Craig; Stimson, Chad

    2016-01-01

    Performance-related effects of system level temperature changes can be a key consideration in the design of many types of optical instruments. This is especially true for space-based imagers, which may require complex thermal control systems to maintain alignment of the optical components. Structural-Thermal-Optical-Performance (STOP) analysis is a multi-disciplinary process that can be used to assess the performance of these optical systems when subjected to the expected design environment. This type of analysis can be very time consuming, which makes it difficult to use as a trade study tool early in the project life cycle. In many cases, only one or two iterations can be performed over the course of a project. This limits the design space to best practices since it may be too difficult, or take too long, to test new concepts analytically. In order to overcome this challenge, automation, and a standard procedure for performing these studies is essential. A methodology was developed within the framework of the Comet software tool that captures the basic inputs, outputs, and processes used in most STOP analyses. This resulted in a generic, reusable analysis template that can be used for design trades for a variety of optical systems. The template captures much of the upfront setup such as meshing, boundary conditions, data transfer, naming conventions, and post-processing, and therefore saves time for each subsequent project. A description of the methodology and the analysis template is presented, and results are described for a simple telescope optical system.

  2. Transmittance measurements at DIRT-II

    Science.gov (United States)

    Curcio, J. A.; Haught, K. M.; Woytko, M. A.

    1980-07-01

    This is a report on the NRL experiments at the DIRT-II tests sponsored by the Atmospheric Sciences Laboratory at the White Sands Missile Range in July 1970. The NRL experiment was designed to measure spectral transmittance through smoke and dust clouds generated by detonations of various explosive charges and also by impact of artillery rounds. Spectral transmission data as a function of time for 0.55 micrometers, 1.06 micrometers, and 10.37 micrometers were obtained for 63 events comprised of static detonations and artillery rounds. Transmission data for 1.06 micrometers, in most cases were similar and equal to 0.55 micrometers. In dry soil conditions the 10.37 micrometers channel showed higher transmittance values than the visible channel. There are indications that 10.37 micrometers transmittance in wet soil events is lower than visible presumably because of strong liquid water absorption at the IR wavelength.

  3. Psalm 98: Sing 'n nuwe lied tot lof van die Koning, Jahwe

    African Journals Online (AJOL)

    Psalm 98: Sing 'n nuwe lied tot lof van die Koning, Jahwe. W S Prinsloo. Universiteit van Pretoria. Abstract. Sing a new song in praise of the king, Yahweh. This article surveys the problems of interpreting Psalm. 98. The chief problems are those concerned with determining the Gattung, the redactional history, strophic ...

  4. Van graf tot wieg ; de rol van fintech door de generaties heen

    NARCIS (Netherlands)

    Vries, A. de; Bakas, A.

    2015-01-01

    Als financiële dienstverlener moet je rekening houden met mensen van alle leeftijden en uit alle lagen van de bevolking. Van de hulpbehoevende senior tot de nieuwsgierige kleuter. We vroegen 2 experts wat verschillende levensfasen typeert, hoe deze persona’s tegen technologie aankijken en hoe

  5. Monitoring projecten Bewegende stad : nodigt de vernieuwde inrichting uit tot meer bewegen?

    NARCIS (Netherlands)

    de Jong, Johan; Slender, Hans; Verbree, Hanneke; Wiggers, Hiske

    ‘De stad als sportschool’ illustreert dat de gemeente Groningen stadjers uitnodigt om te sporten en bewegen in de openbare ruimte van Groningen. Van hardlopen in het Noorderplantsoen, skeeleren in het Stadspark tot crossfit trainingen op de Grote Markt, steeds meer mensen sporten in de openbare

  6. Van Sappho tot De Sade : momenten in de geschiedenis van de seksualiteit

    NARCIS (Netherlands)

    Bremmer, J.

    1988-01-01

    Waarom werd in het oude Griekenland een homoseksuele verhouding tussen twee volwassenen niet geaccepteerd? Waarom reikte in de middeleeuwen het verbod van incest tot aan de grenzen der verwantschap? Waarom was de negentiende eeuw doodsbenauwd voor masturbatie? Waarom zijn de bordelen met hun

  7. Second Question How Did this Shift in ToT Come About?

    Indian Academy of Sciences (India)

    Affirmative policies of the government. Increase in minimum support prices (MSP) for staple grains. Surge in rural wages as a result of employment guarantee scheme. Notes: Moving on on factors behind this shift in ToT, the last on my list: Surge in rural wages as a result of the massive rural employment guarantee scheme ...

  8. De middeleeuwen zijn anders. Cultuur en literatuur van de 12de tot de 15de eeuw

    NARCIS (Netherlands)

    Janssens, Jef

    2005-01-01

    De middeleeuwers pletten de aardbol tot een platte schijf waar men kon afvallen. De middeleeuwers verdrukten de vrouw en verbrandden meedogenloos hun heksen. De middeleeuwers bevolkten hun wereld met afschuwelijke monsters. Kortom tussen de Oudheid en de Renaissance ging de Europese cultuur door de

  9. TVT compared with TVT-O and TOT: results from the Norwegian National Incontinence Registry.

    Science.gov (United States)

    Dyrkorn, Ole A; Kulseng-Hanssen, Sigurd; Sandvik, Leiv

    2010-11-01

    The aim of this study is to compare the outcome and complication rates of the tension-free vaginal tape (TVT) operations with the transobturator vaginal tape (TVT-O and TOT) operations in the treatment of urinary stress incontinence. This is a multicenter, prospective cohort study. Preoperative and postoperative assessments included a validated Stress and Urge Incontinence Questionnaire, a 24-h pad test, and a standardized stress test. The study included 5,942 women--4,281 women had a TVT operation and 731 and 373 women had TVT-O and TOT operations, respectively. Median follow-up time was 8 months. Women in the TVT group had less leakage during stress test and fewer subjective stress incontinence symptoms, and were more satisfied with the operation compared with the women in TVT-O and TOT groups, but more complications were reported after TVT operation. The TVT operation is more efficient than TVT-O and TOT operations in treating stress incontinent women.

  10. Van strafbaar tot huwbaar : homorecht wereldwijd (presentatie op Ministerie van Buitenlandse Zaken, Den Haag)

    NARCIS (Netherlands)

    Waaldijk, C.

    2015-01-01

    Met de door hem ontwikkelde Global Index on Legal Recognition of Homosexual Orientation (GILRHO) geeft Kees Waaldijk op een schaal van nul tot acht aan, hoe ver een land is met het uit het strafrecht halen van homoseksualiteit, met het verbieden van homodiscriminatie en met het erkennen van

  11. On the isolation of elemental carbon (EC) for micro-molar 14C accelerator mass spectrometry: development of a hybrid reference material for 14C-EC accuracy assurance, and a critical evaluation of the thermal optical kinetic (TOK) EC isolation procedure

    Science.gov (United States)

    Currie, L. A.; Kessler, J. D.

    2005-10-01

    The primary objective of the research reported here has been the development of a hybrid reference material (RM) to serve as a test of accuracy for elemental carbon (EC) isotopic (14C) speciation measurements. Such measurements are vital for the quantitative apportionment of fossil and biomass sources of "soot" (EC), the tracer of fire that has profound effects on health, atmospheric visibility, and climate. Previous studies of 14C-EC measurement quality, carried out with NIST SRM 1649a (Urban Dust), showed a range of results, but since the "truth" was not known for this natural matrix RM, one had to rely on isotopic-chemical consistency evidence (14C in PAH, EC) of measurement validity (Currie et al., 2002). Components of the new Hybrid RM (DiesApple), however, have known 14C and EC composition, and they are nearly orthogonal (isotopically and chemically). NIST SRM 2975 (Forklift Diesel Soot) has little or no 14C, and its major compositional component is EC; SRM 1515 (Apple Leaves) has the 14C content of biomass-C, and it has little or no EC. Thus, the Hybrid RM can serve as an absolute isotopic test for the absence of EC-mimicking pyrolysis-C (char) from SRM 1515 in the EC isolate of the Hybrid RM, as well as a test for conservation of its dominant soot fraction throughout the isolation procedure. The secondary objective was to employ the Hybrid RM for the comparative evaluation of the thermal optical kinetic (TOK) and thermal optical transmission (TOT) methods for the isolation of EC for micro-molar carbon accelerator mass spectrometry (AMS). As part of this process, the relatively new TOK method was subjected to a critical evaluation and significant development. Key findings of our study are: (1) both methods exhibited biomass-C "leakage"; for TOT, the EC fraction isolated for AMS contained about 8% of the original biomass-C; for TOK, the refractory carbon (RC) isolated contained about 3% of the original biomass-C.; (2) the initial isothermal oxidation stage of

  12. On the isolation of elemental carbon (EC for micro-molar 14C accelerator mass spectrometry: development of a hybrid reference material for 14C-EC accuracy assurance, and a critical evaluation of the thermal optical kinetic (TOK EC isolation procedure

    Directory of Open Access Journals (Sweden)

    L. A. Currie

    2005-01-01

    Full Text Available The primary objective of the research reported here has been the development of a hybrid reference material (RM to serve as a test of accuracy for elemental carbon (EC isotopic (14C speciation measurements. Such measurements are vital for the quantitative apportionment of fossil and biomass sources of 'soot' (EC, the tracer of fire that has profound effects on health, atmospheric visibility, and climate. Previous studies of 14C-EC measurement quality, carried out with NIST SRM 1649a (Urban Dust, showed a range of results, but since the 'truth' was not known for this natural matrix RM, one had to rely on isotopic-chemical consistency evidence (14C in PAH, EC of measurement validity (Currie et al., 2002. Components of the new Hybrid RM (DiesApple, however, have known 14C and EC composition, and they are nearly orthogonal (isotopically and chemically. NIST SRM 2975 (Forklift Diesel Soot has little or no 14C, and its major compositional component is EC; SRM 1515 (Apple Leaves has the 14C content of biomass-C, and it has little or no EC. Thus, the Hybrid RM can serve as an absolute isotopic test for the absence of EC-mimicking pyrolysis-C (char from SRM 1515 in the EC isolate of the Hybrid RM, as well as a test for conservation of its dominant soot fraction throughout the isolation procedure. The secondary objective was to employ the Hybrid RM for the comparative evaluation of the thermal optical kinetic (TOK and thermal optical transmission (TOT methods for the isolation of EC for micro-molar carbon accelerator mass spectrometry (AMS. As part of this process, the relatively new TOK method was subjected to a critical evaluation and significant development. Key findings of our study are: (1 both methods exhibited biomass-C 'leakage'; for TOT, the EC fraction isolated for AMS contained about 8% of the original biomass-C; for TOK, the refractory carbon (RC isolated contained about 3% of the original biomass-C.; (2 the initial isothermal oxidation stage

  13. 47 CFR 80.911 - VHF transmitter.

    Science.gov (United States)

    2010-10-01

    ... resistance when operated with a primary supply voltage of 13.6 volts DC. (d) When an individual demonstration... paragraph must be met as follows: (1) Measurements of primary supply voltage and transmitter output power must be made with the equipment drawing energy only from ship's battery; (2) The primary supply voltage...

  14. Efficacy of using radio transmitters to monitor least tern chicks

    Science.gov (United States)

    Whittier, Joanna B.; Leslie, David M.

    2005-01-01

    Little is known about Least Tern (Sterna antillarum) chicks from the time they leave the nest until fledging because they are highly mobile and cryptically colored. We evaluated the efficacy of using radiotelemetry to monitor Interior Least Tern (S. a. athalassos) chicks at Salt Plains National Wildlife Refuge, Oklahoma. In 1999, we attached radio transmitters to 26 Least Tern chicks and tracked them for 2-17 days. No adults abandoned their chicks after transmitters were attached. Transmitters did not appear to alter growth rates of transmittered chicks (P = 0.36) or prevent feather growth, although dermal irritation was observed on one chick. However, without frequent reattachment, transmitters generally did not remain on chicks feather growth and transmitter removal, presumably by adult terns. Although the presence of transmitters did not adversely affect Least Tern chicks, future assessments should investigate nonintrusive methods to improve retention of transmitters on young chicks and reduce the number of times that chicks need to be handled.

  15. 47 CFR 101.131 - Transmitter construction and installation.

    Science.gov (United States)

    2010-10-01

    ... appropriately labeled pilot lamp or meter which will provide continuous visual indication at the transmitter... indication when the transmitter is radiating, or, in lieu thereof, a pilot lamp or meter which will provide... responsible operating personnel 24 hours per day. ...

  16. Predicting ambient aerosol thermal-optical reflectance (TOR) measurements from infrared spectra: organic carbon

    Science.gov (United States)

    Dillner, A. M.; Takahama, S.

    2015-03-01

    Organic carbon (OC) can constitute 50% or more of the mass of atmospheric particulate matter. Typically, organic carbon is measured from a quartz fiber filter that has been exposed to a volume of ambient air and analyzed using thermal methods such as thermal-optical reflectance (TOR). Here, methods are presented that show the feasibility of using Fourier transform infrared (FT-IR) absorbance spectra from polytetrafluoroethylene (PTFE or Teflon) filters to accurately predict TOR OC. This work marks an initial step in proposing a method that can reduce the operating costs of large air quality monitoring networks with an inexpensive, non-destructive analysis technique using routinely collected PTFE filter samples which, in addition to OC concentrations, can concurrently provide information regarding the composition of organic aerosol. This feasibility study suggests that the minimum detection limit and errors (or uncertainty) of FT-IR predictions are on par with TOR OC such that evaluation of long-term trends and epidemiological studies would not be significantly impacted. To develop and test the method, FT-IR absorbance spectra are obtained from 794 samples from seven Interagency Monitoring of PROtected Visual Environment (IMPROVE) sites collected during 2011. Partial least-squares regression is used to calibrate sample FT-IR absorbance spectra to TOR OC. The FTIR spectra are divided into calibration and test sets by sampling site and date. The calibration produces precise and accurate TOR OC predictions of the test set samples by FT-IR as indicated by high coefficient of variation (R2; 0.96), low bias (0.02 μg m-3, the nominal IMPROVE sample volume is 32.8 m3), low error (0.08 μg m-3) and low normalized error (11%). These performance metrics can be achieved with various degrees of spectral pretreatment (e.g., including or excluding substrate contributions to the absorbances) and are comparable in precision to collocated TOR measurements. FT-IR spectra are also

  17. Predicting transmittance spectra of electrophotographic color prints

    Science.gov (United States)

    Mourad, Safer; Emmel, Patrick; Hersch, Roger D.

    2000-12-01

    For dry toner electrophotographic color printers, we present a numerical simulation model describing the color printer responses based on a physical characterization of the different electrophotographic process steps. The proposed model introduces a Cross Transfer Efficiency designed to predict the color transmittance spectra of multi-color prints by taking into account the transfer influence of each deposited color toner layer upon the other layers. The simulation model leads to a better understanding of the factors that have an impact on printing quality. In order to avoid the additional optical non-linearities produced by light reflection on paper, we have limited the present investigation to transparency prints. The proposed model succeeded to predict the transmittance spectra of printed wedges combining two color toner layers with a mean deviation less than CIE-LAB (Delta) E equals 2.5.

  18. Ultrafast photoconductor detector-laser-diode transmitter

    International Nuclear Information System (INIS)

    Wang, C.L.; Davis, B.A.; Davies, T.J.; Nelson, M.A.; Thomas, M.C.; Zagarino, P.A.

    1987-01-01

    We report the results of an experiment in which we used an ultrafast, photoconductive, radiation detector to drive a fast laser-diode transmitter. When we irradiated the neutron-damaged Cr-doped GaAs detector with 17-MeV electron beams, the temporal response was measured to be less than 30 ps. The pulses from this detector modulated a fast GaAlAs laser diode to transmit the laser output through 30- and 1100-m optical fibers. Preliminary results indicate that 50- and 80-ps time resolutions, respectively, are obtainable with these fibers. We are now working to integrate the photoconductive detector and the laser diode transmitter into a single chip

  19. Ultrafast photoconductive detector-laser-diode transmitter

    International Nuclear Information System (INIS)

    Wang, C.L.; Davies, T.J.; Nelson, M.A.; Thomas, M.C.; Zagarino, P.A.; Davis, B.A.

    1987-01-01

    The authors report the results of an experiment in which they used an ultrafast, photoconductive, radiation detector to drive a fast laser-diode transmitter. When they irradiated the neutron-damaged Cr-doped Ga/As detector with 17-MeV electron beams, the temporal response of was measured to be less than 30 ps. The pulses from this detector modulated a fast GaAlAs laser diode to transmit the laser output through 30- and 1100-m optical fibers. Preliminary results indicate that 50- and 80-ps time resolutions, respectively, are obtainable with these fibers. They are now working to integrate the photoconductive detector and the laser diode transmitter into a single chip

  20. Agricultural applications of NIR reflectance and transmittance

    DEFF Research Database (Denmark)

    Gislum, René

    2009-01-01

    There has been a considerable increase in the use of near infrared (NIR) reflectance and transmittance spectroscopy technologies for rapid determination of quality parameters in agriculture, including applications within crop product quality, feed and food quality, manure quality, soil analyses etc....... As a result it was decided to arrange a seminar within the Nordic Association of Agricultural Scientists. This is a report of the meeting....

  1. The high energy behavior of the forward scattering parameters -- σtot, ρ, and B

    International Nuclear Information System (INIS)

    Block, M.M.; Halzen, F.; Margolis, B.; White, A.R.

    1994-10-01

    Utilizing the most recent experimental data, the authors reanalyze high energy anti pp and pp data, using, two distinct (and dissimilar) analysis techniques: (1) asymptotic amplitude analysis, under the assumption that they have reached ''asymptopia'', and (2) an eikonal model whose amplitudes are designed to mimic real QCD amplitudes. The former gives strong evidence for a log(s/s o ) dependence at current energies and not log 2 (s/s o ), and demonstrates that odderons are not necessary to explain the experimental data. The latter gives a unitary model for extrapolation into true ''asymptopia'' from current energies, allowing the authors to predict the values of the total cross section at future supercolliders. Using the QCD-model, they obtain σ tot (16 TeV) = 109 ± 4mb and σ tot (40 TeV) = 124 ± 4 mb

  2. De betekenis van Paulus' oproep tot de groet met de heilige kus

    NARCIS (Netherlands)

    Voogd, Joanna Bernarda

    Dit boek is een studie naar de betekenis van de Paulijnse oproep tot de groet met de heilige kus. In vier passages in het Nieuwe Testament is deze oproep vindbaar: “Groet alle broeders (en zusters) met de heilige kus” (1 Tes 5:26) of “groet elkaar met de heilige kus” (1 Kor 16:20; 2 Kor 13:12 en

  3. Effect of alkaline earth metal doping on thermal, optical, magnetic and dielectric properties of BiFeO3 nanoparticles

    International Nuclear Information System (INIS)

    Bhushan, B; Das, D; Basumallick, A; Bandopadhyay, S K; Vasanthacharya, N Y

    2009-01-01

    Substrate-free pure-phase BiFeO 3 (BFO) nanoparticles doped with alkaline earth metals (Ba, Sr and Ca) have been synthesized by a sol-gel route and their thermal, optical, dielectric and magnetic properties are discussed. The characteristic structural phase transitions of BFO nanoparticles are found to occur at much lower temperatures. A reduction of the Neel temperature has been observed in the doped samples in comparison with the pristine one, whereas the band gap shows a reverse trend. Iron was found to be only in the Fe 3+ valence state in all the doped samples. Magnetoelectric coupling is seen in our samples. Weak ferromagnetism is observed at room temperature in all of the doped and undoped BFO nanoparticles with the largest value of coercive field ∼1.78 kOe and saturation magnetization ∼2.38 emu g -1 for Ba and Ca doped BFO nanoparticles, respectively.

  4. Dynamic reliability of digital-based transmitters

    Energy Technology Data Exchange (ETDEWEB)

    Brissaud, Florent, E-mail: florent.brissaud.2007@utt.f [Institut National de l' Environnement Industriel et des Risques (INERIS), Parc Technologique Alata, BP 2, 60550 Verneuil-en-Halatte (France) and Universite de Technologie de Troyes - UTT, Institut Charles Delaunay - ICD and UMR CNRS 6279 STMR, 12 rue Marie Curie, BP 2060, 10010 Troyes Cedex (France); Smidts, Carol [Ohio State University (OSU), Nuclear Engineering Program, Department of Mechanical Engineering, Scott Laboratory, 201 W 19th Ave, Columbus OH 43210 (United States); Barros, Anne; Berenguer, Christophe [Universite de Technologie de Troyes (UTT), Institut Charles Delaunay (ICD) and UMR CNRS 6279 STMR, 12 rue Marie Curie, BP 2060, 10010 Troyes Cedex (France)

    2011-07-15

    Dynamic reliability explicitly handles the interactions between the stochastic behaviour of system components and the deterministic behaviour of process variables. While dynamic reliability provides a more efficient and realistic way to perform probabilistic risk assessment than 'static' approaches, its industrial level applications are still limited. Factors contributing to this situation are the inherent complexity of the theory and the lack of a generic platform. More recently the increased use of digital-based systems has also introduced additional modelling challenges related to specific interactions between system components. Typical examples are the 'intelligent transmitters' which are able to exchange information, and to perform internal data processing and advanced functionalities. To make a contribution to solving these challenges, the mathematical framework of dynamic reliability is extended to handle the data and information which are processed and exchanged between systems components. Stochastic deviations that may affect system properties are also introduced to enhance the modelling of failures. A formalized Petri net approach is then presented to perform the corresponding reliability analyses using numerical methods. Following this formalism, a versatile model for the dynamic reliability modelling of digital-based transmitters is proposed. Finally the framework's flexibility and effectiveness is demonstrated on a substantial case study involving a simplified model of a nuclear fast reactor.

  5. Wireless Tots

    Science.gov (United States)

    Scott, Lee-Allison

    2003-01-01

    The first wireless technology program for preschoolers was implemented in January at the Primrose School at Bentwater in Atlanta, Georgia, a new corporate school operated by Primrose School Franchising Co. The new school serves as a testing and training facility for groundbreaking educational approaches, including emerging innovations in…

  6. Lomi And Totò : An Ethiopian-Italian Colonial or Postcolonial “Love Story”?

    Directory of Open Access Journals (Sweden)

    Giovanna Trento

    2007-01-01

    Full Text Available Lomi and Totò. An Ethiopian-Italian Colonial or Postcolonial “Love Story”? introduces various and still open questions related to the current necessity of a deeper study of the Italian colonial presence in the African Horn. The source of this article is the relationship between Lomi and Totò, an Ethiopian woman and an Italian man who are not alive anymore, as it is seen and told by their five children (with some additional illuminating interviews. This story started during the Italian colonial fascist period, continued in the Fifties and Sixties in postcolonial East Africa, ended up in Italy in the Eighties, and is still alive in the memory of Lomi and Totò descendents. This “love story” has different shades and can be read from several points of view: personal, sentimental, familiar, social, anthropological, and historical. For some aspects it is unique, but for others it is exemplary of its time and allows us to look into important dynamics during wide and complex periods. Giovanna Trento in this article, thanks to the observation of this “private history”, highlights a certain controversial and unstable degree of fluidity between colonial and postcolonial periods, also questioning the degree of freedom individuals might have within a given social framework, thus suggesting some crucial and sometimes ambiguous issues related to: the use of racial laws in the fascist period; notions of concubinage, marriage and citizenship; gender and power relations; subaltern conditions and marginality within Italian colonialism; discrepancies between portraying African women and relating to them; new African-Italian identities; building collective memory and family storytelling; reproducing, suffering, or overcoming the “colony” today.

  7. TOT versus TVT – mesh surgical treatment in stress urinary incontinence

    Directory of Open Access Journals (Sweden)

    Ovidiu Bratu

    2015-12-01

    Full Text Available Introduction: Stress urinary incontinence is a highly debilitating condition, with an important impact over the quality of life. When the conservative treatment fails, the surgical treatment is a viable solution. Minimally invasive sling procedures have become the gold standard of surgical management for stress urinary incontinence (SUI in women. Material and methods: The study was conducted on 68 patients with stress urinary incontinence, 52 have undergone the retropubic tension-free vaginal tape and 16 patients were operated using the transobturator tape procedure. All the patients were evaluated before the operation and the indication of the surgical treatment was established on the basis of physical examination (all the patients had positive cough test, abdominal ultrasound (to determine postvoid residual urine volume, urinalysis and urine culture (the majority of the patients have had before the operation recurrent urinary tract infections. Results: The satisfaction was similar in both groups of patients, with an average satisfaction rate of 91% for TVT and 86% for the patients who have undergone TOT procedure. The patients were in a proportion of 78,9% at menopause, with an average number of natural births of 1.9 and a mean BMI of 28.2. Regarding the surgical duration, this has varied between 20 and 40 minutes, being higher in the TVT cases (up to 5-7 minutes longer than TOT, because cystoscopy was performed during the operation to verify if the bladder was perforated or not. The urethral catheter was removed immediately after the operation in the case of the TOT procedure and in the day after the operation for the patients who have undergone TVT procedures (all of these patients associated genital prolapse. The hospitalization time was 3 days. We haven’t encountered significant intraoperative and postoperative complications. Conclusions: The TOT and TVT procedures have proven to be highly effective and safe methods in the treatment of

  8. Opportunistic transmitter selection for selfless overlay cognitive radios

    KAUST Repository

    Shaqfeh, Mohammad

    2013-11-01

    We propose an opportunistic strategy to grant channel access to the primary and secondary transmitters in causal selfless overlay cognitive radios over block-fading channels. The secondary transmitter helps the primary transmitter by relaying the primary messages opportunistically, aided by a buffer to store the primary messages temporarily. The optimal channel-aware transmitter- selection strategy is the solution of the maximization of the average secondary rate under the average primary rate requirement and the buffer stability constraints. Numerical results demonstrate the gains of the proposed opportunistic selection strategy. © 2013 IEEE.

  9. Atmospheric transmittance model for photosynthetically active radiation

    International Nuclear Information System (INIS)

    Paulescu, Marius; Stefu, Nicoleta; Gravila, Paul; Paulescu, Eugenia; Boata, Remus; Pacurar, Angel; Mares, Oana; Pop, Nicolina; Calinoiu, Delia

    2013-01-01

    A parametric model of the atmospheric transmittance in the PAR band is presented. The model can be straightforwardly applied for calculating the beam, diffuse and global components of the PAR solar irradiance. The required inputs are: air pressure, ozone, water vapor and nitrogen dioxide column content, Ångström's turbidity coefficient and single scattering albedo. Comparison with other models and ground measured data shows a reasonable level of accuracy for this model, making it suitable for practical applications. From the computational point of view the calculus is condensed into simple algebra which is a noticeable advantage. For users interested in speed-intensive computation of the effective PAR solar irradiance, a PC program based on the parametric equations along with a user guide are available online at http://solar.physics.uvt.ro/srms

  10. 29 CFR 1921.15 - Transmittal of record.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Transmittal of record. 1921.15 Section 1921.15 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR... WORKERS' COMPENSATION ACT Decision and Order § 1921.15 Transmittal of record. Immediately following the...

  11. Evaluation of vaginal implant transmitters in elk (Cervus elaphus nelsoni).

    Science.gov (United States)

    Bruce K. Johnson; Terrance McCoy; Christopher O. Kochanny; Rachel C. Cook

    2006-01-01

    The effects of vaginal implant transmitters for tissue damage after 11 wk in 13 captive adult elk (Cervus elaphus nelsoni) and subsequent reproductive performance in 38 free-ranging elk were evaluated. Vaginal implant transmitters are designed to be shed at parturition and are used to locate birth sites of wild ungulates; however, potential adverse...

  12. 47 CFR 25.281 - Automatic Transmitter Identification System (ATIS).

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Automatic Transmitter Identification System (ATIS). 25.281 Section 25.281 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES SATELLITE COMMUNICATIONS Technical Operations § 25.281 Automatic Transmitter...

  13. 22 CFR 181.7 - Transmittal to the Congress.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Transmittal to the Congress. 181.7 Section 181... PUBLICATION OF INTERNATIONAL AGREEMENTS § 181.7 Transmittal to the Congress. (a) International agreements.... Background statements, while not expressly required by the act, have been requested by the Congress and have...

  14. Analysis of an Intelligent Temperature Transmitter for Process Control

    African Journals Online (AJOL)

    Percentage error shows acceptable points at -0.04%, 0.04% and -0.1%. For higher percentage error readings, it is necessary to connect a resistor of value between 250Ω and 1100Ω between the current loop and the transmitter. The future of transmitter technology is however the wireless sensor node (WSN) incorporating ...

  15. Radiation hardening of CMOS-based circuitry in SMART transmitters

    International Nuclear Information System (INIS)

    Loescher, D.H.

    1993-02-01

    Process control transmitters that incorporate digital signal processing could be used advantageously in nuclear power plants; however, because such transmitters are too sensitive to radiation, they are not used. The Electric Power Research Institute sponsored work at Sandia National Laboratories under EPRI contract RP2614-58 to determine why SMART transmitters fail when exposed to radiation and to design and demonstrate SMART transmitter circuits that could tolerate radiation. The term ''SMART'' denotes transmitters that contain digital logic. Tests showed that transmitter failure was caused by failure of the complementary metal oxide semiconductors (CMOS)-integrated circuits which are used extensively in commercial transmitters. Radiation-hardened replacements were not available for the radiation-sensitive CMOS circuits. A conceptual design showed that a radiation-tolerant transmitter could be constructed. A prototype for an analog-to-digital converter subsection worked satisfactorily after a total dose of 30 megarads(Si). Encouraging results were obtained from preliminary bench-top tests on a dc-to-dc converter for the power supply subsection

  16. Comparison between ASHRAE and ISO thermal transmittance calculation methods

    DEFF Research Database (Denmark)

    Blanusa, Petar; Goss, William P.; Roth, Hartwig

    2007-01-01

    is proportional to the glazing/frame sightline distance that is also proportional to the total glazing spacer length. An example calculation of the overall heat transfer and thermal transmittance (U-value or U-factor) using the two methods for a thermally broken, aluminum framed slider window is presented....... The fenestration thermal transmittance calculations analyses presented in this paper show that small differences exist between the calculated thermal transmittance values produced by the ISO and ASHRAE methods. The results also show that the overall thermal transmittance difference between the two methodologies...... decreases as the total window area (glazing plus frame) increases. Thus, the resulting difference in thermal transmittance values for the two methods is negligible for larger windows. This paper also shows algebraically that the differences between the ISO and ASHRAE methods turn out to be due to the way...

  17. Event generators for address event representation transmitters

    Science.gov (United States)

    Serrano-Gotarredona, Rafael; Serrano-Gotarredona, Teresa; Linares Barranco, Bernabe

    2005-06-01

    Address Event Representation (AER) is an emergent neuromorphic interchip communication protocol that allows for real-time virtual massive connectivity between huge number neurons located on different chips. By exploiting high speed digital communication circuits (with nano-seconds timings), synaptic neural connections can be time multiplexed, while neural activity signals (with mili-seconds timings) are sampled at low frequencies. Also, neurons generate 'events' according to their activity levels. More active neurons generate more events per unit time, and access the interchip communication channel more frequently, while neurons with low activity consume less communication bandwidth. In a typical AER transmitter chip, there is an array of neurons that generate events. They send events to a peripheral circuitry (let's call it "AER Generator") that transforms those events to neurons coordinates (addresses) which are put sequentially on an interchip high speed digital bus. This bus includes a parallel multi-bit address word plus a Rqst (request) and Ack (acknowledge) handshaking signals for asynchronous data exchange. There have been two main approaches published in the literature for implementing such "AER Generator" circuits. They differ on the way of handling event collisions coming from the array of neurons. One approach is based on detecting and discarding collisions, while the other incorporates arbitration for sequencing colliding events . The first approach is supposed to be simpler and faster, while the second is able to handle much higher event traffic. In this article we will concentrate on the second arbiter-based approach. Boahen has been publishing several techniques for implementing and improving the arbiter based approach. Originally, he proposed an arbitration squeme by rows, followed by a column arbitration. In this scheme, while one neuron was selected by the arbiters to transmit his event out of the chip, the rest of neurons in the array were

  18. 47 CFR 90.473 - Operation of internal transmitter control systems through licensed fixed control points.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Operation of internal transmitter control... Transmitter Control Internal Transmitter Control Systems § 90.473 Operation of internal transmitter control systems through licensed fixed control points. An internal transmitter control system may be operated...

  19. Development of a wireless nuclear signal transmitter

    Energy Technology Data Exchange (ETDEWEB)

    Soodsakorn, A

    1994-12-31

    This thesis aims at the development of a nuclear signal transmission system using radio frequency as carrier. The system is helpful for long distance data transmission especially convenient in high level radiation area. The transmitting system comprises of pulse height ADCs with serial output, digital data modulation, frequency modulation and a l watt C B 27.125 MHz transmitter. The sequential data transmission is controlled by micro controller. The receiving system comprises of detector, noise filter and data demodulator where the signals in form of nuclear spectrum will be displayed on a micro-computer through R S-232{sub C} serial data transmission. It is found that the developed system can transmit a nuclear pulse height in the range of 0-10 V with the pulse width varying from 0.5-10 us. The linear correlation of the pulse height ADCs conversion is 0.998. The system can transmit a nuclear pulse rate of 600 cpm with the serial data of 1200 baud rate without error. At a l watt transmitted power, the system can on air cover an area of l km radius for continuous operation

  20. A simple mixture to enhance muscle transmittance

    Science.gov (United States)

    Oliveira, Luís; Lage, Armindo; Clemente, Manuel Pais; Tuchin, Valery V.

    2008-06-01

    Skeletal muscle is a fibrous tissue composed by muscle fibers and interstitial fluid. Due to this constitution, the muscle presents a non uniform refractive index profile that origins strong light scattering. One way to improve tissue transmittance is to reduce this refractive index mismatch by immersing the muscle in an optical clearing agent. As a consequence of such immersion tissue also suffers dehydration. The study of the optical clearing effect created by a simple mixture composed by ethanol, glycerol and distilled water has proven its effectiveness according to the variations observed in the parameters under study. The effect was characterized in terms of its magnitude, time duration and histological variations. The applied treatment has created a small reduction of the global sample refractive index that is justified by the long time rehydration caused by water in the immersing solution. From the reduction in sample pH we could also identify the dehydration process created in the sample. The immersion treatment has originated fiber bundle contraction and a spread distribution of the muscle fiber bundles inside. New studies with the mixture used, or with other combinations of its constituents might be interesting to perform with the objective to develop new clinical procedures.

  1. COP of heat pumps. From definition to sales promotion; Warmtepomp COP. Van definitie tot verkoopargument

    Energy Technology Data Exchange (ETDEWEB)

    Bartholomeus, T.M.C. [Grasso Products, Den Bosch (Netherlands)

    2006-10-15

    Due to new EU-regulations heat pumps are once more very much in demand. A negative side effect of this popularity is the incomplete and defective information overrunning the market. The COP (coefficient of performance) of a heat pump degenerates from a definition into a sales promotion. This article brings clearness in these COP matters. [Dutch] Het blijkt dat de markt voor warmtepompen wordt overspoeld met onvolledige informatie ten gunste van hogere verkoopcijfers. Het rendement van een warmtepomp, verpakt in het Engelse COP (coefficient of performance) verwordt van definitie tot verkoopargument. In principe is daar niets mis mee, maar weI als het te pas en onpas gebruikt wordt, zonder enige relatie met het gebruiksdoel, de toepassing en bedrijfsvoering. Dit artikel heeft als doel om appels en peren in de COP-communicatie te scheiden.

  2. Comparing the Transvaginal Tape (TVT and Transobturator Tape (TOT in Stress Urinary Incontinance, for their Efficiency and their Effects on Quality of Life.

    Directory of Open Access Journals (Sweden)

    Mahir Mehdiyev

    2010-06-01

    Full Text Available Objective: To compare the success rates, complications and the effects on the life quality of TOT and TVT operation. Methods: 32 patients who were diagnosed as stress urinary incontinance between March 2005 and november 2006 were included in the study. All patients filled urinar diary and underwent uradinamical exemination after negative urine culture. To evaluate the quality of life I-QoL questionnaire was used. The patients were randomised for TOT and TVT operations. Results: 17 patients underwent TOT operation while 15 patients underwent TVT operations. The mean operation time of TOT group (13.5 min was significantly shorter than TVT groups (18.3 min. There were no intraoperative complications in TOT group whereas there were one bladder injury and one rigt inguinal side subcutaneous hematoma. In early postoperative period there were no complication was seen in TOT group but there were 3 globe vesicale cases were seen in TVT group. there were no differences about blood loss between two groups. the mean hospitalisation time was 2 days in bout two groups (except complicated cases. 1.5 months after the operation all patients were evaluated wiyh cough stress test, residuel urine volume, subjective complains and I-QoL questionneir, no differences were detected between two groups. One patient in TOT group and three patients in TVT group was complicated with de-novo urge incontinance. In our study the objective success rates are 82.3% and 86.7% in TOT and TVT groups respectively. Conclusions: In our study we found that the success rates of TOT and TVT operations were similar and complication rates of TOT was less than TVT group. Further studies that include wide patient populations and has log term follow-up, are needed to get more objective results.

  3. Vergelijking van verschillende benzodiazepinen met betrekking tot de potentie voor sedatie en spierverslapping en de werkingsduur in de rat

    NARCIS (Netherlands)

    Jansen van ' t Land C; van der Laan JW

    1989-01-01

    In dit onderzoek werden de benzodiazepinen (BZD) onderling vergeleken met betrekking tot de potentie voor sedatie en spierverslapping en de werkingsduur. Voor de Crl:(WI)BR rat van Charles River zijn voor de volgende benzodiazepinen de ED50 waarden m.b.t. sedatie en spierverslapping bepaald: .

  4. Tinnitus en arbeid. Een onderzoek naar de invloed van stressoren op tinnitus en de mogelijkheid tot werken

    NARCIS (Netherlands)

    Nienke Riemersma, [No Value

    2010-01-01

    Het al dan niet kunnen werken heeft te maken met stressoren die de tinnitus en/of de mogelijkheid tot werken negatief beïnvloeden. Welke stressoren van invloed zijn is in opdracht van de commissie Tinnitus en Hyperacusis van de Nederlandse Vereniging Voor Slechthorenden (NVVS) door de

  5. Van wonen tot marketing : een sociaal-filosofische analyse van het moderne behoefte-georiënteerd handelen

    NARCIS (Netherlands)

    K. van Toledo (Kruin)

    1985-01-01

    textabstractToledo, K. van, Van wonen tot marketing. Een sociaal-filosofische analyse van het moderne behoefte-georiënteerd handelen/From living to marketing. An analysis of the social philosophical nature of modern want-oriented action, Proefschrift/ Doctoral thesis, Landbouwhogeschool, Wageningen

  6. Discussion on informatization teaching of certain radar transmitter

    Science.gov (United States)

    Liang, Guanhui; Lv, Guizhou; Meng, Yafeng

    2017-04-01

    With the development of informatization, the traditional teaching method of certain radar transmitter is more and more difficult to meet the need of cultivating new type of high-quality military talents. This paper first analyzes the problems traditional teaching method of certain radar transmitter, and then puts forward the strategy of informatization teaching, and finally elaborates the concrete steps and contents of informatization teaching. Using the multimedia maintenance training system, information simulation training system and network courses and other informatization means, effectively improves the master degree to radar transmitter by trainees, but also lays a good foundation for repair in the next step.

  7. Correlation between thermal, optical and morphological properties of heterogeneous blends of poly(3-hexylthiophene) and thermoplastic polyurethane

    International Nuclear Information System (INIS)

    PatrIcio, PatrIcia S O; Calado, Hallen D R; Oliveira, Flavio A C de; Righi, Ariete; Neves, Bernardo R A; Silva, Glaura G; Cury, Luiz A

    2006-01-01

    A correlation between thermal, optical and morphological properties of self-sustained films formed from blends of poly(3-hexylthiophene) (P3HT) and thermoplastic polyurethane (TPU), with 1, 10 and 20 wt% of P3HT in TPU, is established. Images of scanning electron microscopy (SEM) show the formation of domains of P3HT into the TPU matrix, characterizing the blend material as heterogeneous. The heat capacity (C p ) dependence on P3HT contents was investigated in a large temperature interval. In the region of the TPU glass transition, the difference between the experimental and predicted ΔC p values is more pronounced for the 1 wt% case, which strongly suggests that in this case there is a higher influence of the P3HT chains on the TPU matrix. The SEM images for the 1 wt% blended film present the formation of the smallest P3HT domains in the TPU matrix. The relatively high reduction of the PL intensity of the pure electronic transition peak in the 1 wt% blended film, in comparison to the other blended films and also to a pure P3HT film, favours the assumption that the smallest P3HT domains are at the origin of a more structural disordered character. This fact is in agreement with the results obtained by Raman spectroscopy and also by photoluminescence resolved by polarization in stretched self-sustained films, showing an ample correlation between morphological, thermal and optical properties of these blended materials. In addition, the thermoplastic properties of the polyurethane configure very good conditions for tensile drawing of P3HT and other conjugated polymer molecules

  8. Correlation between thermal, optical and morphological properties of heterogeneous blends of poly(3-hexylthiophene) and thermoplastic polyurethane

    Energy Technology Data Exchange (ETDEWEB)

    PatrIcio, PatrIcia S O [Departamento de QuImica, Instituto de Ciencias Exatas, Universidade Federal de Minas Gerais, CP 702, 30123-970, Belo Horizonte MG (Brazil); Calado, Hallen D R [Departamento de QuImica, Instituto de Ciencias Exatas, Universidade Federal de Minas Gerais, CP 702, 30123-970, Belo Horizonte MG (Brazil); Oliveira, Flavio A C de [Departamento de Fisica, Instituto de Ciencias Exatas, Universidade Federal de Minas Gerais, CP 702, 30123-970, Belo Horizonte MG (Brazil); Righi, Ariete [Departamento de Fisica, Instituto de Ciencias Exatas, Universidade Federal de Minas Gerais, CP 702, 30123-970, Belo Horizonte MG (Brazil); Neves, Bernardo R A [Departamento de Fisica, Instituto de Ciencias Exatas, Universidade Federal de Minas Gerais, CP 702, 30123-970, Belo Horizonte MG (Brazil); Silva, Glaura G [Departamento de QuImica, Instituto de Ciencias Exatas, Universidade Federal de Minas Gerais, CP 702, 30123-970, Belo Horizonte MG (Brazil); Cury, Luiz A [Departamento de Fisica, Instituto de Ciencias Exatas, Universidade Federal de Minas Gerais, CP 702, 30123-970, Belo Horizonte MG (Brazil)

    2006-08-16

    A correlation between thermal, optical and morphological properties of self-sustained films formed from blends of poly(3-hexylthiophene) (P3HT) and thermoplastic polyurethane (TPU), with 1, 10 and 20 wt% of P3HT in TPU, is established. Images of scanning electron microscopy (SEM) show the formation of domains of P3HT into the TPU matrix, characterizing the blend material as heterogeneous. The heat capacity (C{sub p}) dependence on P3HT contents was investigated in a large temperature interval. In the region of the TPU glass transition, the difference between the experimental and predicted {delta}C{sub p} values is more pronounced for the 1 wt% case, which strongly suggests that in this case there is a higher influence of the P3HT chains on the TPU matrix. The SEM images for the 1 wt% blended film present the formation of the smallest P3HT domains in the TPU matrix. The relatively high reduction of the PL intensity of the pure electronic transition peak in the 1 wt% blended film, in comparison to the other blended films and also to a pure P3HT film, favours the assumption that the smallest P3HT domains are at the origin of a more structural disordered character. This fact is in agreement with the results obtained by Raman spectroscopy and also by photoluminescence resolved by polarization in stretched self-sustained films, showing an ample correlation between morphological, thermal and optical properties of these blended materials. In addition, the thermoplastic properties of the polyurethane configure very good conditions for tensile drawing of P3HT and other conjugated polymer molecules.

  9. Structural-Thermal-Optical-Performance (STOP) Model Development and Analysis of a Field-widened Michelson Interferometer

    Science.gov (United States)

    Scola, Salvatore J.; Osmundsen, James F.; Murchison, Luke S.; Davis, Warren T.; Fody, Joshua M.; Boyer, Charles M.; Cook, Anthony L.; Hostetler, Chris A.; Seaman, Shane T.; Miller, Ian J.; hide

    2014-01-01

    An integrated Structural-Thermal-Optical-Performance (STOP) model was developed for a field-widened Michelson interferometer which is being built and tested for the High Spectral Resolution Lidar (HSRL) project at NASA Langley Research Center (LaRC). The performance of the interferometer is highly sensitive to thermal expansion, changes in refractive index with temperature, temperature gradients, and deformation due to mounting stresses. Hand calculations can only predict system performance for uniform temperature changes, under the assumption that coefficient of thermal expansion (CTE) mismatch effects are negligible. An integrated STOP model was developed to investigate the effects of design modifications on the performance of the interferometer in detail, including CTE mismatch, and other three- dimensional effects. The model will be used to improve the design for a future spaceflight version of the interferometer. The STOP model was developed using the Comet SimApp'TM' Authoring Workspace which performs automated integration between Pro-Engineer®, Thermal Desktop®, MSC Nastran'TM', SigFit'TM', Code V'TM', and MATLAB®. This is the first flight project for which LaRC has utilized Comet, and it allows a larger trade space to be studied in a shorter time than would be possible in a traditional STOP analysis. This paper describes the development of the STOP model, presents a comparison of STOP results for simple cases with hand calculations, and presents results of the correlation effort to bench-top testing of the interferometer. A trade study conducted with the STOP model which demonstrates a few simple design changes that can improve the performance seen in the lab is also presented.

  10. Experimental determination of net protein charge and A(tot) and K(a) of nonvolatile buffers in canine plasma.

    Science.gov (United States)

    Constable, Peter D; Stämpfli, Henry R

    2005-01-01

    Acid-base abnormalities frequently are present in sick dogs. The mechanism for an acid-base disturbance can be determined with the simplified strong ion approach, which requires accurate values for the total concentration of plasma nonvolatile buffers (A(tot)) and the effective dissociation constant for plasma weak acids (K(a)). The aims of this study were to experimentally determine A(tot) and K(a) values for canine plasma. Plasma was harvested from 10 healthy dogs; the concentrations of quantitatively important strong ions (Na+, K+, Ca2+, Mg2+, Cl-, L-lactate) and nonvolatile buffer ions (total protein, albumin, phosphate) were determined; and the plasma was tonometered with CO2 at 37 degrees C. Strong ion difference (SID) was calculated from the measured strong ion concentrations, and nonlinear regression was used to estimate values for A(tot) and K(a), which were validated with data from an in vitro and in vivo study. Mean (+/- SD) values for canine plasma were A(tot) = (17.4 +/- 8.6) mM (equivalent to 0.273 mmol/g of total protein or 0.469 mmol/g of albumin); K(a) = (0.17 +/- 0.11) x 10(-7); pK(a) = 7.77. The calculated SID for normal canine plasma (pH = 7.40; P(CO2) = 37 mm Hg; [total protein] = 64 g/L) was 27 mEq/L. The net protein charge for normal canine plasma was 0.25 mEq/g of total protein or 0.42 mEq/g of albumin. Application of the experimentally determined values for A(tot), K(a), and net protein charge should improve understanding of the mechanism for complex acid-base disturbances in dogs.

  11. analysis of an analysis of an intelligent temperature transmitter

    African Journals Online (AJOL)

    eobe

    temperature sensors and analyze a typical Rosemount Intelligent Temperature Transmitter (RITT) with a view to identifying and ... material science and communication technologies [2]. ... Some benefits of the 4-20mA transmission standard.

  12. PLZT light transmittance memory driven with an asymmetric voltage pulse

    International Nuclear Information System (INIS)

    Inoue, Kazuhiko; Morita, Takeshi

    2010-01-01

    PLZT is a ferroelectric electro-optic material, which has been operated with a constant voltage supply to keep a certain optical property. In this study, we propose an optical transmittance memory effect by controlling the domain conditions. The keypoint is to use an asymmetric voltage pulse. In the positive direction, a sufficiently-large voltage is applied to align the polarization directions. After this operation, a relatively small light transmittance is memorized even after removing the electric field. On the other hand, in the negative direction, the amplitude of the voltage is adjusted to the coercive electric field. In this condition, the domain structure is almost the same as the depolarization state. With this voltage supply, the maximum light transmittance can be kept after removing the electric field. Using these voltage operations, the PLZT can obtain two light transmittance states depending on the domain structure. This memory effect should be useful for innovative optical scanners or shutters in the future.

  13. Efficient and Compact Semiconductor Laser Transmitter Modules, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Continue development of a Compact Transmitter Module (CTM). Modules will be voltage controlled to adjust wavlength using temperature and drive current settings. The...

  14. Low-Power-Consumption Integrated PPM Laser Transmitter, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Conventional PPM laser transmitters, a CW laser followed by a modulator, are inherently inefficient since the data must be carved from the laser's steady output. 95%...

  15. Low-Power-Consumption Integrated PPM Laser Transmitter, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Conventional PPM laser transmitters, a CW laser followed by a modulator, are inherently inefficient since the data must be carved from the laser's steady output. 95%...

  16. 47 CFR 80.873 - VHF radiotelephone transmitter.

    Science.gov (United States)

    2010-10-01

    ...) The transmitter must deliver a carrier power between 8 and 25 watts into a 50 ohm effective resistance... 50 ohms effective resistance over the frequency band specified in § 80.871(d). An individual...

  17. High Temperature Telemetry Transmitter for Venus Exploration, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed S-band telemetry transmitter will operate in the exterior Venusian corrosive, high pressure, 460oC ambient atmosphere without being contained in a...

  18. High Temperature Telemetry Transmitter for Venus Exploration, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed S-band telemetry transmitter will operate in the exterior Venusian high pressure, 465?aC ambient atmosphere without being contained in a thermally...

  19. Photonic integrated transmitter and receiver for NG-PON2

    Science.gov (United States)

    Tavares, Ana; Lopes, Ana; Rodrigues, Cláudio; Mãocheia, Paulo; Mendes, Tiago; Brandão, Simão.; Rodrigues, Francisco; Ferreira, Ricardo; Teixeira, António

    2014-08-01

    In this paper the authors present a monolithic Photonic Integrated Circuit which includes a transmitter and a receiver for NG-PON2. With this layout it is possible to build an OLT and, by redesigning some filters, also an ONU. This technology allows reducing the losses in the transmitter and in the receiver, increasing power budget, and also reducing the OEO conversions, which has been a major problem that operators want to surpass.

  20. Optimal Scheduling for Energy Harvesting Transmitters with Hybrid Energy Storage

    OpenAIRE

    Ozel, Omur; Shahzad, Khurram; Ulukus, Sennur

    2013-01-01

    We consider data transmission with an energy harvesting transmitter which has a hybrid energy storage unit composed of a perfectly efficient super-capacitor (SC) and an inefficient battery. The SC has finite space for energy storage while the battery has unlimited space. The transmitter can choose to store the harvested energy in the SC or in the battery. The energy is drained from the SC and the battery simultaneously. In this setting, we consider the offline throughput maximization problem ...

  1. Investigating the Use of a Diffusion Flame to Produce Black Carbon Standards for Thermal- Optical Analysis of Carbonaceous Aerosols

    Science.gov (United States)

    Ortiz Montalvo, D. L.; Kirchstetter, T. W.; Soto-García, L. L.; Mayol-Bracero, O. L.

    2006-12-01

    Combustion generated particles are a concern to both climate and public health due to their ability to scatter and absorb solar radiation and alter cloud properties, and because they are small enough to be inhaled and deposit in the lungs where they may cause respiratory and other health problems. Specific concern is focused on particles that originate from the combustion of diesel fuel. Diesels particles are composed mainly of carbonaceous material, especially in locations where diesel fuel sulfur is low. These particles are black due to the strongly light absorbing nature of the refractory carbon components, appropriately called black carbon (BC). This research project focuses on the uncertainty in the measurement of BC mass concentration, which is typically determined by analysis of particles collected on a filter using a thermal-optical analysis (TOA) method. Many studies have been conducted to examine the accuracy of the commonly used variations of the TOA method, which vary in their sample heating protocol, carrier gas, and optical measurement. These studies show that BC measurements are inaccurate due to the presence of organic carbon (OC) in the aerosols. OC may co-evolve with BC or char to form BC during analysis, both of which make it difficult to distinguish between the OC and BC in the sample. The goal of this study is to develop the capability of producing standard samples of known amounts of BC, either alone or mixed with other aerosol constituents, and then evaluate which TOA methods accurately determine the BC amount. An inverted diffusion flame of methane and air was used to produce particle samples containing only BC as well as samples of BC mixed with humic acid (HA). Our study found that HA is light absorbing and catalyzes the combustion of BC. It is expected that both of these attributes will challenge the ability of TOA methods in distinguishing between OC and BC, such as the simple two step TOA method which relies solely on temperature to

  2. 基于风险矩阵的BOT-TOT-PPP项目融资风险评估%The Risk Assessment of BOT-TOT-PPP Project Financing Based on Risk Matrix

    Institute of Scientific and Technical Information of China (English)

    李力

    2012-01-01

    风险评估在BOT-TOT-PPP项目中至关重要。本文通过大量案例调研指出,现阶段BOT-TOT-PPP项目融资的风险因素来源于项目外部的政治、经济、文化、社会(环保)以及内部的合同制订、工程技术能力、管理能力和投融资能力方面。风险矩阵和Borda序值对风险的量化评估表明,此类项目现阶段的关键风险集中在政府项目融资管理的专业化水平较低、合同双方对关键指标的确定不合理、投融资管理和工程实施存在问题等方面。%Risk assessment is paramount in BOT-TOT-PPP project.It is indicated through a great deal of cases that risk factors of BOT-TOT-PPP project financing currently derive from politics,economy,culture,society(environmental protection) beyond project,and contract establishment,engineering technology ability,management ability,investment financing ability within project.Quantitative evaluation of risk matrix and Borda counting on risk shows that today major risk of such project concentrates on low management level of governmental project financing,irrational key index in mutual contract,problems involved in financing management and engineering implementation.

  3. 47 CFR 90.475 - Operation of internal transmitter control systems in specially equipped systems.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Operation of internal transmitter control... Control Internal Transmitter Control Systems § 90.475 Operation of internal transmitter control systems in specially equipped systems. (a) An internal transmitter control system need not be designed to meet the...

  4. 47 CFR 90.471 - Points of operation in internal transmitter control systems.

    Science.gov (United States)

    2010-10-01

    ...) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Transmitter Control Internal Transmitter Control Systems § 90.471 Points of operation in internal transmitter control systems. The... licensee for internal communications and transmitter control purposes. Operating positions in internal...

  5. Gli spazi marginali di un personaggio bizzarro: l’adattamento del romanzo Totò il buono

    Directory of Open Access Journals (Sweden)

    Matteo Martelli

    2012-11-01

    Full Text Available Il saggio propone uno studio del romanzo di Cesare Zavattini, Totò il buono, e della riscrittura filmica Miracolo a Milano (firmata da Zavattini stesso e Vittorio De Sica attraverso l’analisi della figura del protagonista, Totò, personaggio eccentrico e buono. In maniera particolare, a partire dalla presenza in entrambi i testi di spazi di marginalità culturale dai quali si costruiscono le qualità bizzarre del personaggio, il saggio descrive come il lavoro d’adattamento rielabori le formulazioni del romanzo attraverso l’introduzione di un punto di vista della tradizione, estetica e antropologica, del grottesco e del realismo popolare, integrando e spostando al tempo stesso il precedente stato di marginalità da uno spazio asociale alla valorizzazione, sul piano immaginario, di un’utopia comunitaria.

  6. Sal die Era van Aquarius met ’n “skrikkelsprong” in die millennium tot sy reg kom

    Directory of Open Access Journals (Sweden)

    D. P. Smits

    2001-09-01

    Full Text Available Waar ons nou die einde van die 2de millennium AD nader, het dit duidelik geword dat daar heelwat verwarring heers oor hoe en waarom ons kalender opgestel is soos dit is. Die lengte van ’n jaar en van die astronomiese eeu word beide gedefinieer aan die hand van die posisie van ’n bepaalde punt aan die hemel, wat bekend staan as die Eerste punt van Aries. Deurdat hierdie punt met betrekking tot die sterre-agtergrond beweeg, skep dit probleme om sterrekundige gebeurtenisse, wat die seisoene bepaal, aan ’n vaste datum in ons kalender te koppel. Die Katolieke Kerk se wens om Paasfees op ’n datum te vier wat deur spesifieke astronomiese gebeurtenis se bepaal word, het in die 16de eeu gelei tot die implementering van die kalender wat nou internasionaal in gebruik is.

  7. Problematika Pengertian Aanslag-Aanslag tot en feit: Perbandingan Makar dalam KUHP, WvSNI dan Sr.

    Directory of Open Access Journals (Sweden)

    Widati Wulandari

    2017-12-01

    Full Text Available Makar dalam praktik penegakan hukum pidana di Indonesia sering kali ditafsirkan terlalu luas dan karenanya menjangkau perbuatan yang tidak selayaknya dikategorikan sebagai tindak pidana yang mengancam keselamatan negara. Tulisan ini hendak menelusuri kembali pemaknaan dua konsep penting dalam Kitab Undang-Undang Hukum Pidana Indonesia (Wetboek van Strafrecht Nederlands-Indie; WvSNI, yaitu aanslag maupun aanslag tot en feit. Metoda yang digunakan adalah metode penemuan hukum dan perbandingan hukum. Temuan terpenting adalah adanya kekeliruan penerjemahan istilah aanslag dan aanslag tot en feit secara otomatis sebagai makar dalam berbagai pasal KUHP. Koreksi terhadap itu seharusnya dilakukan agar penegakan hukum pidana tidak memunculkan ketidakadilan dalam wujud reaksi negara yang tidak proporsional dengan kadar kesalahan.

  8. Summary of the OECD Environmental Outlook to 2050; Samenvatting OESO milieuverkenning tot 2050

    Energy Technology Data Exchange (ETDEWEB)

    Manders, A.J.G.

    2012-03-15

    The OECD Environmental Outlook to 2050 asks 'What will the next four decades bring?' Based on joint modelling by the OECD and the Netherlands Environmental Assessment Agency (PBL), it looks forward to the year 2050 to find out what demographic and economic trends might mean for the environment if the world does not adopt more ambitious green policies. It also looks at what policies could change that picture for the better. This Outlook focuses on four areas: climate change, biodiversity, freshwater and health impacts of pollution. These four key environmental challenges were identified by the previous Environmental Outlook to 2030 (OECD, 2008) as 'Red Light' issues requiring urgent attention [Dutch] De Organisatie voor Economische Samenwerking en Ontwikkeling (OESO) maakt milieuverkenningen om beleidsmakers beter inzicht te geven in de schaal en samenhang van toekomstige uitdagingen rond milieu. De OESO maakt daarbij gebruik van modellen om projecties te maken. Voor deze verkenning is intensief samengewerkt met het Planbureau voor de Leefomgeving (PBL). De milieuverkenning tot 2050 verkent de gevolgen voor het milieu als meer ambitieuze maatregelen voor het beheer van onze natuurlijke hulpbronnen uitblijven. De verkenning stelt beleidsmaatregelen voor die deze situatie zouden kunnen verbeteren en richt zich op de vier meest urgente thema's: klimaatverandering, biodiversiteit, water en de gezondheidsimplicaties van vervuiling.

  9. Characterization of a pixelated CdTe Timepix detector operated in ToT mode

    International Nuclear Information System (INIS)

    Billoud, T.; Leroy, C.; Papadatos, C.; Roux, J.S.; Pichotka, M.; Pospisil, S.

    2017-01-01

    A 1 mm thick CdTe sensor bump-bonded to a Timepix readout chip operating in Time-over-Threshold (ToT) mode has been characterized in view of possible applications in particle and medical physics. The CdTe sensor layer was segmented into 256 × 256 pixels, with a pixel pitch of 55  μm. This CdTe Timepix device, of ohmic contact type, has been exposed to alpha-particles and photons from an 241 Am source, photons from a 137 Cs source, and protons of different energies (0.8–10 MeV) delivered by the University of Montreal Tandem Accelerator. The device was irradiated on the negatively biased backside electrode. An X-ray per-pixel calibration commonly used for this type of detector was done and its accuracy and resolution were assessed and compared to those of a 300  μm thick silicon Timepix device. The electron mobility-lifetime product (μ e τ e ) of CdTe for protons of low energy has been obtained from the Hecht equation. Possible polarization effects have been also investigated. Finally, information about the homogeneity of the detector was obtained from X-ray irradiation.

  10. High Power RF Transmitters for ICRF Applications on EAST

    International Nuclear Information System (INIS)

    Mao Yuzhou; Yuan Shuai; Zhao Yanping; Zhang Xinjun; Chen Gen; Cheng Yan; Wang Lei; Ju Songqing; Deng Xu; Qin Chengming; Yang Lei; Kumazawa, R.

    2013-01-01

    An Ion Cyclotron Range of Frequency (ICRF) system with a radio frequency (RF) power of 4 × 1.5 MW was developed for the Experimental Advanced Superconducting Tokamak (EAST). High RF power transmitters were designed as a part of the research and development (R and D) for an ICRF system with long pulse operation at megawatt levels in a frequency range of 25 MHz to 70 MHz. Studies presented in this paper cover the following parts of the high power transmitter: the three staged high power amplifier, which is composed of a 5 kW wideband solid state amplifier, a 100 kW tetrode drive stage amplifier and a 1.5 MW tetrode final stage amplifier, and the DC high voltage power supply (HVPS). Based on engineering design and static examinations, the RF transmitters were tested using a matched dummy load where an RF output power of 1.5 MW was achieved. The transmitters provide 6 MW RF power in primary phase and will reach a level up to 12 MW after a later upgrade. The transmitters performed successfully in stable operations in EAST and HT-7 devices. Up to 1.8 MW of RF power was injected into plasmas in EAST ICRF heating experiments during the 2010 autumn campaign and plasma performance was greatly improved.

  11. Microminiature radio frequency transmitter for communication and tracking applications

    Science.gov (United States)

    Crutcher, Richard I.; Emery, Mike S.; Falter, Kelly G.; Nowlin, C. H.; Rochelle, Jim M.; Clonts, Lloyd G.

    1997-02-01

    A micro-miniature radio frequency (rf) transmitter has been developed and demonstrated by the Oak Ridge National Laboratory. The objective of the rf transmitter development was to maximize the transmission distance while drastically shrinking the overall transmitter size, including antenna. Based on analysis and testing, an application-specific integrated circuit (ASIC) with a 16-GHz gallium arsenide (GaAs) oscillator and integrated on-chip antenna was designed and fabricated using microwave monolithic integrated circuit (MMIC) technology. Details of the development and the results of various field tests are discussed. The rf transmitter is applicable to covert surveillance and tracking scenarios due to its small size of 2.2 multiplied by 2.2 mm, including the antenna. Additionally, the 16-GHz frequency is well above the operational range of consumer-grade radio scanners, providing a degree of protection from unauthorized interception. Variations of the transmitter design have been demonstrated for tracking and tagging beacons, transmission of digital data, and transmission of real-time analog video from a surveillance camera. Preliminary laboratory measurements indicate adaptability to direct-sequence spread-spectrum transmission, providing a low probability of intercept and/or detection. Concepts related to law enforcement applications are presented.

  12. Effects of radio transmitters on nesting captive mallards

    Science.gov (United States)

    Houston, Robert A.; Greenwood, Raymond J.

    1993-01-01

    Radio packages may subtly affect bird behavior and condition, and thus could bias results from studies using this technique. To assess effects on reproduction of mallards (Anas platyrhynchos), we tested 3 types of back-mounted radio packages on captive females. Eight paired females were randomly assigned to each of 4 treatments: 4-g transmitter attached with sutures and glue, 10-g or 18-g transmitter attached with a harness, and no transmitter (control). All mallards were fed ad libitum. No differences were detected among treatments in number of clutches, clutch size, nesting interval, egg mass, or body mass; powers (range = 0.15-0.48) of tests were low. Feather wear and skin irritation around radio packages were minimal. Birds retained sutured transmitters for an average of 43.5 days (range = 3-106 days) and harness transmitters for the duration of the study (106 days). Sutures were not reliable and presently are not recommended as an attachment method. Caution is advised in applying these results to radio-equipped mallards in the wild.

  13. Data transmission through power line of smart transmitter

    International Nuclear Information System (INIS)

    Kim, Jong Hyun; Kang, Hyun Gook; Seong, Poong Hyun

    1996-01-01

    In this study, the method to use the phase shift keying (PSK) communication technique in smart transmitter is presented. In nuclear applications, smart transmitters for various parameters are expected to improve the accuracy of measurement and to reduce the load of calibration work. The capability of communication in field level is the most important merit of the smart transmitter. The most popular method is using of digital and analog techniques simultaneously - transmitting measurements from the field at 4-20mA while modulating the current to carry digital information in both directions over the same twisted pairs. Conventional smart transmitters use the frequency shift keying (FSK) method for digital communication. Generally, however, the FSK method has the speed limit at 1200 bps. Amount of information to transmit becomes increasing as the processing technique is improved. The PSK method is noticeable alternative for high speed digital communication, but it has non-zero DC component. In order to use the PSK method in the field transmission with smart transmitter, the method to remove the DC component is studied in this work

  14. Comparison of TVT and TOT on urethral mobility and surgical outcomes in stress urinary incontinence with hypermobile urethra.

    Science.gov (United States)

    Cavkaytar, Sabri; Kokanalı, Mahmut Kuntay; Guzel, Ali Irfan; Ozer, Irfan; Aksakal, Orhan Seyfi; Doganay, Melike

    2015-07-01

    To compare the change of urethral mobility after midurethral sling procedures in stress urinary incontinence with hypermobile urethra and assess these findings with surgical outcomes. 141 women who agreed to undergo midurethral sling operations due to stress urinary incontinence with hypermobile urethra were enrolled in this non-randomized prospective observational study. Preoperatively, urethral mobility was measured by Q tip test. All women were asked to complete Urogenital Distress Inventory Short Form (UDI-6) and Incontinence Impact Questionnaire Short Form (IIQ-7) to assess the quality of life. Six months postoperatively, Q tip test and quality of life assessment were repeated. The primary surgical outcomes were classified as cure, improvement and failure. Transient urinary obstruction, de novo urgency, voiding dysfunction were secondary surgical outcomes. Of 141 women, 50 (35. 5%) women underwent TOT, 91 (64.5%) underwent TVT. In both TOT and TVT groups, postoperative Q tip test values, IIQ-7 and UDI-6 scores were statistically reduced when compared with preoperative values. Postoperative Q tip test value in TVT group was significantly smaller than in TOT group [25°(15-45°) and 20° (15-45°), respectively]. When we compared the Q-tip test value, IIQ-7 and UDI-6 scores changes, there were no statistically significant changes between the groups. Postoperative urethral mobility was more frequent in TOT group than in TVT group (40% vs 23.1%, respectively). Postoperative primary and secondary outcomes were similar in both groups. Although midurethral slings decrease the urethtal hypermobility, postoperative mobility status of urethra does not effect surgical outcomes of midurethral slings in women with preoperative urethral hypermobility. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  15. Experimental determination of net protein charge, [A]tot, and Ka of nonvolatile buffers in bird plasma.

    Science.gov (United States)

    Stämpfli, Henry; Taylor, Michael; McNicoll, Carl; Gancz, Ady Y; Constable, Peter D

    2006-06-01

    The quantitative mechanistic acid-base approach to clinical assessment of acid-base status requires species-specific values for [A]tot (the total concentration of nonvolatile buffers in plasma) and Ka (the effective dissociation constant for weak acids in plasma). The aim of this study was to determine [A]tot and Ka values for plasma in domestic pigeons. Plasma from 12 healthy commercial domestic pigeons was tonometered with 20% CO2 at 37 degrees C. Plasma pH, Pco2, and plasma concentrations of strong cations (Na, K, Ca), strong anions (Cl, L-lactate), and nonvolatile buffer ions (total protein, albumin, phosphate) were measured over a pH range of 6.8-7.7. Strong ion difference (SID) (SID5=Na+K+Ca-Cl-lactate) was used to calculate [A]tot and Ka from the measured pH and Pco2 and SID5. Mean (+/-SD) values for bird plasma were as follows: [A]tot=7.76+/-2.15 mmol/l (equivalent to 0.32 mmol/g of total protein, 0.51 mmol/g of albumin, 0.23 mmol/g of total solids); Ka=2.15+/-1.15x10(-7); and pKa=6.67. The net protein charge at normal pH (7.43) was estimated to be 6 meq/l; this value indicates that pigeon plasma has a much lower anion gap value than mammals after adjusting for high mean L-lactate concentrations induced by restraint during blood sampling. This finding indicates that plasma proteins in pigeons have a much lower net anion charge than mammalian plasma protein. An incidental finding was that total protein concentration measured by a multianalyzer system was consistently lower than the value for total solids measured by refractometer.

  16. Hans Hulshof, Erik Kwakernaak en Frans Wilhelm, Geschiedenis van het talenonderwijs in Nederland. Onderwijs in de moderne talen van 1500 tot heden

    Directory of Open Access Journals (Sweden)

    Hilda T.A. Amsing

    2016-11-01

    Full Text Available Hans Hulshof, Erik Kwakernaak en Frans Wilhelm, Geschiedenis van het talenonderwijs in Nederland. Onderwijs in de moderne talen van 1500 tot heden (Groningen: Passage, 2015, 468 pp., isbn 978 90 5452 315 4.

  17. Joint Transmitter-Receiver Optimization in the Downlink CDMA Systems

    Directory of Open Access Journals (Sweden)

    Mohammad Saquib

    2002-08-01

    Full Text Available To maximize the downlink code-division multiple access (CDMA system capacity, we propose to minimize the total transmitted power of the system subject to users′ signal-to-interference ratio (SIR requirements via designing optimum transmitter sequences and utilizing linear optimum receivers (minimum mean square error (MMSE receiver. In our work on joint transmitter-receiver design for the downlink CDMA systems with multiple antennas and multipath channels, we develop several optimization algorithms by considering various system constraints and prove their convergence. We empirically observed that under the optimization algorithm with no constraint on the system, the optimum receiver structure matches the received transmitter sequences. A simulation study is performed to see how the different practical system constraints penalize the system with respect to the optimum algorithm with no constraint on the system.

  18. 10 CFR 455.152 - Transmittal of record on review.

    Science.gov (United States)

    2010-01-01

    ... Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION GRANT PROGRAMS FOR SCHOOLS AND HOSPITALS AND BUILDINGS OWNED BY UNITS OF LOCAL GOVERNMENT AND PUBLIC CARE INSTITUTIONS Administrative Review § 455.152 Transmittal of record on review. On or before 15 days from receipt of a notice requesting administrative...

  19. Luminous transmittance and phase transition temperature of VO 2 ...

    African Journals Online (AJOL)

    The phase transition temperature (τc) of the films was obtained from both the transmittance and sheet resistance against temperature curves. A change in sheet resistance of 2 to 3 orders of magnitude was observed for both undoped and Ce-doped VO2 films. Comparison between undoped and doped VO2 films revealed ...

  20. ALTERNATIVE METHOD FOR ON SITE EVALUATION OF THERMAL TRANSMITTANCE

    Directory of Open Access Journals (Sweden)

    Aleksandar Janković

    2017-08-01

    Full Text Available Thermal transmittance or U-value is an indicator of the building envelope thermal properties and a key parameter for evaluation of heat losses through the building elements due to heat transmission. It can be determined by calculation based on thermal characteristics of the building element layers. However, this value does not take into account the effects of irregularities and degradation of certain elements of the envelope caused by aging, which may lead to errors in calculation of the heat losses. An effective and simple method for determination of thermal transmittance is in situ measurement, which is governed by the ISO 9869-1:2014 that defines heat flow meter method. This relatively expensive method leaves marks and damages surface of the building element. Furthermore, the final result is not always reliable, in particular when the building element is light or when the weather conditions are not suitable. In order to avoid the above mentioned problems and to estimate the real thermal transmittance value an alternative experimental method, here referred as the natural convection and radiation method, is proposed in this paper. For determination of thermal transmittance, this method requires only temperatures of inside and outside air, as well as the inner wall surface temperature. A detailed statistical analysis, performed by the software package SPSS ver. 20, shows several more advantages of this method comparing to the standard heat flow meter one, besides economic and non-destructive benefits.

  1. Mark 4A DSN receiver-exciter and transmitter subsystems

    Science.gov (United States)

    Wick, M. R.

    1986-01-01

    The present configuration of the Mark 4A DSN Receiver-Exciter and Transmitter Subsystems is described. Functional requirements and key characteristics are given to show the differences in the capabilities required by the Networks Consolidation task for combined High Earth Orbiter and Deep Space Network tracking support.

  2. 47 CFR 22.507 - Number of transmitters per station.

    Science.gov (United States)

    2010-10-01

    ... those that operate together as a system (e.g., trunked systems, simulcast systems), rather than independently. (b) Split of large systems. The FCC may split wide-area systems into two or more stations for... PUBLIC MOBILE SERVICES Paging and Radiotelephone Service § 22.507 Number of transmitters per station...

  3. Snake mortality associated with late season radio-transmitter implantation

    Science.gov (United States)

    D. Craig Rudolph; Shirley J. Burgdorf; Richard R. Schaefer; Richard N. Conner; Robert T. Zappalorth

    1998-01-01

    Radio-telemetry is an increasingly used procedure to obtain data on the biology of free-living snakes (Reinert 1992, 1994). In Texas and Louisiana we have been using the surgical technique of Weatherhead and Anderka (1984) to implant transmitters in timber rattlesnakes (Crotalus horridus) and Louisiana pine snakes (Pituophis melanoleucus...

  4. Transmittivity and wavefunctions in one-dimensional generalized Aubry models

    International Nuclear Information System (INIS)

    Basu, C.; Mookerjee, A.; Sen, A.K.; Thakur, P.K.

    1990-07-01

    We use the vector recursion method of Haydock to obtain the transmittance of a class of generalized Aubry models in one-dimension. We also study the phase change of the wavefunctions as they travel through the chain and also the behaviour of the conductance with changes in size. (author). 10 refs, 9 figs

  5. Spectral transmittance of the spectacle scale of snakes and geckos

    NARCIS (Netherlands)

    Doorn, van K.; Sivak, J.G.

    2015-01-01

    The spectral transmittance of the optical media of the eye plays a substantial role in tuning the spectrum of light available for capture by the retina. Certain squamate reptiles, including snakes and most geckos, shield their eyes beneath a layer of transparent, cornified skin called the

  6. 47 CFR 73.685 - Transmitter location and antenna system.

    Science.gov (United States)

    2010-10-01

    ... Section 73.685 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES... located at the most central point at the highest elevation available. To provide the best degree of... operating on Channels 14-69 with transmitters delivering a peak visual power output of more than 1 kW may...

  7. Surgical insertion of transmitters and telemetry methods in fisheries research

    DEFF Research Database (Denmark)

    Rub, A. Michelle Wargo; Jepsen, Niels; Liedtke, Theresa L.

    2014-01-01

    ) will be described. Effects of surgical insertion of transmitters (ie, tagging) and aspects of the surgical implantation process where collaboration and professional exchanges among nonveterinarian researchers and veterinarians may be most fruitful will be discussed. Although this report focuses on surgical...

  8. Ozone transmittance in a model atmosphere at Ikeja, Lagos state ...

    African Journals Online (AJOL)

    Variation of ozone transmittance with height in the atmosphere for radiation in the 9.6m absorption band was studied using Goody's model atmosphere, with cubic spline interpolation technique to improve the quality of the curve. The data comprising of pressure and temperature at different altitudes (0-22 km) for the month of ...

  9. Towards suppression of all harmonics in a polyphase multipath transmitter

    NARCIS (Netherlands)

    Subhan, S.; Klumperink, Eric A.M.; Nauta, Bram

    2011-01-01

    This work proposes a direct conversion transmitter architecture intended for cognitive radio applications. The architecture is based on the poly-phase multipath technique, which has been shown to cancel out many of the harmonics, sidebands and nonlinearity contributions of a power up-converter using

  10. Airborne Measurements of Atmospheric Methane Using Pulsed Laser Transmitters

    Science.gov (United States)

    Numata, Kenji; Riris, Haris; Wu, Stewart; Gonzalez, Brayler; Rodriguez, Michael; Hasselbrack, William; Fahey, Molly; Yu, Anthony; Stephen, Mark; Mao, Jianping; hide

    2016-01-01

    Atmospheric methane (CH4) is the second most important anthropogenic greenhouse gas with approximately 25 times the radiative forcing of carbon dioxide (CO2) per molecule. At NASA Goddard Space Flight Center (GSFC) we have been developing a laser-based technology needed to remotely measure CH4 from orbit. We report on our development effort for the methane lidar, especially on our laser transmitters and recent airborne demonstration. Our lidar transmitter is based on an optical parametric process to generate near infrared laser radiation at 1651 nanometers, coincident with a CH4 absorption. In an airborne flight campaign in the fall of 2015, we tested two kinds of laser transmitters --- an optical parametric amplifier (OPA) and an optical parametric oscillator (OPO). The output wavelength of the lasers was rapidly tuned over the CH4 absorption by tuning the seed laser to sample the CH4 absorption line at several wavelengths. This approach uses the same Integrated Path Differential Absorption (IPDA) technique we have used for our CO2 lidar for ASCENDS. The two laser transmitters were successfully operated in the NASAs DC-8 aircraft, measuring methane from 3 to 13 kilometers with high precision.

  11. 47 CFR 95.607 - CB transmitter modification.

    Science.gov (United States)

    2010-10-01

    ... FCC (Federal Communications Commission): (a) The addition of any accessory or device not specified in the application for certification and authorized by the FCC in granting the certification; (b) The... cycle at the highest crest of the modulation envelope), as measured at the transmitter output antenna...

  12. 17 CFR 30.12 - Direct foreign order transmittal.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 1 2010-04-01 2010-04-01 false Direct foreign order... FOREIGN FUTURES AND FOREIGN OPTIONS TRANSACTIONS § 30.12 Direct foreign order transmittal. (a) Authorized... investment decisions with respect to foreign futures and foreign option transactions are made by a commodity...

  13. 47 CFR 80.203 - Authorization of transmitters for licensing.

    Science.gov (United States)

    2010-10-01

    ... application a working unit of the type for which certification is desired. Manufacturers of radar equipment... this chapter. Transmitters of a model authorized before October 1, 1986 will be considered type...) Except for radar equipment, applicants for certification of radio equipment designed to satisfy Part II...

  14. Electron-energy-loss and optical-transmittance investigation of Bi2Sr2CaCu2O8

    International Nuclear Information System (INIS)

    Wang, Y.; Feng, G.; Ritter, A.L.

    1990-01-01

    The energy-loss function Im(-1/ε) of Bi 2 Sr 2 CaCu 2 O 8 has been measured over the range E loss =0.8 to 80 eV by transmission electron-energy-loss spectroscopy (EELS) (nonimaging). The energy and momentum resolution were 0.1 eV and 0.04 A -1 , respectively. The low-energy spectra (E loss ≤3 eV) were studied as a function of momentum transfer (0.1 A -1 ≤q≤0.3 A -1 ). A well-defined peak in the loss function at E loss ∼1 eV is observed to disperse with momentum proportional to q 2 . This excitation is analyzed in terms of both an intracell, charge-transfer exciton model and the free-carrier (plasmon) model. The derived effective mass of the exciton m tot /m congruent 1.0 is far too small for a localized exciton. Using the free-carrier model and random-phase-approximation expressions for the dispersion coefficient, the carrier density and carrier effective mass can be determined separately. From our data and similar measurements by Nuecker et al. [Phys. Rev. B 39, 12 379 (1989)], it is found that the effective mass roughly scales with carrier density. A heuristic model is introduced based on the assumption that low-energy gaps exist in portions of the Fermi surface due to structural instabilities. The model suggests how the effective mass could appear to scale with carrier density and why a single Drude term (with frequency-independent effective mass) does not describe the mid- to far-infrared optical spectra. Finally, the optical transmittance of the EELS sample was measured and the spectra analyzed in terms of the free-carrier model

  15. Remote control radioactive-waste removal system uses modulated laser transmitter

    Science.gov (United States)

    Burcher, E. E.; Kopia, L. P.; Rowland, C. W.; Sinclair, A. R.

    1971-01-01

    Laser remote control system consists of transmitter, auto tracker, and receiver. Transmitter and tracker, packaged together and bore sighted, constitute control station, receiver is slave station. Model has five command channels and optical link operating range of 110 m.

  16. Development of slew-rate-limited time-over-threshold (ToT) ASIC for a multi-channel silicon-based ion detector

    Science.gov (United States)

    Uenomachi, M.; Orita, T.; Shimazoe, K.; Takahashi, H.; Ikeda, H.; Tsujita, K.; Sekiba, D.

    2018-01-01

    High-resolution Elastic Recoil Detection Analysis (HERDA), which consists of a 90o sector magnetic spectrometer and a position-sensitive detector (PSD), is a method of quantitative hydrogen analysis. In order to increase sensitivity, a HERDA system using a multi-channel silicon-based ion detector has been developed. Here, as a parallel and fast readout circuit from a multi-channel silicon-based ion detector, a slew-rate-limited time-over-threshold (ToT) application-specific integrated circuit (ASIC) was designed, and a new slew-rate-limited ToT method is proposed. The designed ASIC has 48 channels and each channel consists of a preamplifier, a slew-rate-limited shaping amplifier, which makes ToT response linear, and a comparator. The measured equivalent noise charges (ENCs) of the preamplifier, the shaper, and the ToT on no detector capacitance were 253±21, 343±46, and 560±56 electrons RMS, respectively. The spectra from a 241Am source measured using a slew-rate-limited ToT ASIC are also reported.

  17. Comparison of Effectiveness between Tension-Free Vaginal Tape (TVT) and Trans-Obturator Tape (TOT) in Patients with Stress Urinary Incontinence and Intrinsic Sphincter Deficiency.

    Science.gov (United States)

    Kim, Hyeong Gon; Park, Hyoung Keun; Paick, Sung Hyun; Choi, Woo Suk

    2016-01-01

    The aim of this study was to compare the two types of mid-urethral slings for stress urinary incontinence (SUI) with intrinsic sphincter deficiency (ISD). This retrospective study included patients who underwent tension-free vaginal tape (TVT) procedure or transobturator tape (TOT) procedure by a single surgeon for SUI with ISD, defined as Valsalva leak point pressure (VLPP) TVT and 52 patients received TOT. Age, underlying diseases, Stamey grade, cystocele grade, and presence of urge incontinence were not significantly different between the two groups. Urodynamic parameters including maximal urethral closing pressure, detrusor overactivity, VLPP, urethral hypermobility (Q-tip ≥ 30°), were also comparable between the two groups. Success rate was significantly higher in the TVT group than in the TOT group (95.2% vs. 82.7%, p = 0.009). On multivariate analysis, only TOT surgery (OR = 3.922, 95%CI = 1.223-12.582, p = 0.022) was a risk factor for failure following surgical treatment. TVT is more effective than TOT in treatment of female SUI with ISD.

  18. Multiband RF circuits and techniques for wireless transmitters

    CERN Document Server

    Chen, Wenhua; Ghannouchi, Fadhel M

    2016-01-01

    This book introduces systematic design methods for passive and active RF circuits and techniques, including state-of-the-art digital enhancement techniques. As the very first book dedicated to multiband RF circuits and techniques, this work provides an overview of the evolution of transmitter architecture and discusses current digital predistortion techniques. Readers will find a collection of novel research ideas and new architectures in concurrent multiband power dividers, power amplifiers and related digital enhancement techniques. This book will be of great interest to academic researchers, R&D engineers, wireless transmitter and protocol designers, as well as graduate students who wish to learn the core architectures, principles and methods of multiband RF circuits and techniques. .

  19. Scattering, absorption and transmittance of experimental graphene dental nanocomposites

    Science.gov (United States)

    Pérez, María. M.; Salas, Marianne; Moldovan, Marionara; Dudea, Diana; Yebra, Ana; Ghinea, Razvan

    2017-08-01

    Optical properties of experimental graphene dental nanocomposites were studied. Spectral reflectance was measured and S and K coefficients as well as transmittance of samples were calculated using Kubelka-Munk's equations. The spectral behavior of S, K and T experimental graphene exhibited different trends compared with the commercial nanocomposites and they were statistically different. Experimental nanocomposites show higher scattering and lower transmittance when compared with commercial nanocomposite, probably, due to the shape, type and size of the filler. K for short wavelength of the pre-polymerized experimental nancomposites was very low. According to our results, hidroxypatite with graphene oxide used in dental nanocomposites needs to be improved to reproduce esthetic properties of natural dental tissues and to have potentially clinical applications.

  20. Exciter For X-Band Transmitter And Receiver

    Science.gov (United States)

    Johns, Carl E.

    1989-01-01

    Report describes developmental X-band exciter for X-band uplink subsystem of Deep Space Network. X-band transmitter-exciting signal expected to have fractional frequency stability of 5.2 X 10 to negative 15th power during 1,000-second integration period. Generates coherent test signals for S- and X-band Block III translator of Deep Space Network, Doppler-reference signal for associated Doppler-extractor system, first-local-oscillator signal for associated receiver, and reference signal for associated ranging subsystem. Tests of prototype exciter show controlling and monitoring and internal phase-correcting loops perform according to applicable design criteria. Measurements of stability of frequency and of single-sideband noise spectral density of transmitter-exciting signal made subsequently.

  1. Morphology and transmittance of porous alumina on glass substrate

    Energy Technology Data Exchange (ETDEWEB)

    Guo Peitao, E-mail: guopeitao@hotmail.com [Wuhan University of Technology. Wuhan (China); Xia Zhilin [Wuhan University of Technology. Wuhan (China); Key Laboratory of Low Dimensional Materials and Application Technology, Xiangtan University, Ministry of Education, Xiangtan (China); Xue Yiyu [Wuhan University of Technology. Wuhan (China); Huang Caihua [China Three Gorges University, Yichang (China); Zhao Lixin [Wuhan University of Technology. Wuhan (China)

    2011-02-01

    The porous optical film has higher threshold of laser-induced damage than densified films, for the study of mechanism of laser-induced damage of porous optical film with ordered pore structure. Porous anodic alumina (PAA) film with high transmittance on glass substrate has been prepared. Aluminum film was deposited on glass substrate by means of resistance and electron beam heat (EBH) evaporation. Porous alumina was prepared in oxalic acid solution under different anodizing conditions. At normal incidence, the optical transmittance spectrum over 300-1000 nm spectra region was obtained by spectrophotometer. SEM was introduced to analysis the morphology of the porous alumina film. The pore aperture increased with the increase of anodizing voltage, which resulted in a rapid decrease of the pore concentration and the optical thickness of porous alumina film. Damage morphology of porous alumina film is found to be typically defects initiated, and the defect is the pore presented on the film.

  2. Implementation and validation of a CubeSat laser transmitter

    Science.gov (United States)

    Kingsbury, R. W.; Caplan, D. O.; Cahoy, K. L.

    2016-03-01

    The paper presents implementation and validation results for a CubeSat-scale laser transmitter. The master oscillator power amplifier (MOPA) design produces a 1550 nm, 200mW average power optical signal through the use of a directly modulated laser diode and a commercial fiber amplifier. The prototype design produces high-fidelity M-ary pulse position modulated (PPM) waveforms (M=8 to 128), targeting data rates > 10 Mbit/s while meeting a constraining 8W power allocation. We also present the implementation of an avalanche photodiode (APD) receiver with measured transmitter-to-receiver performance within 3 dB of theory. Via loopback, the compact receiver design can provide built-in self-test and calibration capabilities, and supports incremental on-orbit testing of the design.

  3. Designing Light Beam Transmittance Measuring Tool Using a Laser Pointer

    Science.gov (United States)

    Nuroso, H.; Kurniawan, W.; Marwoto, P.

    2016-08-01

    A simple instrument used for measuring light beam transmittance percentage made of window film has been developed. The instrument uses a laser pointer of 405 nm and 650 nm ±10% as a light source. Its accuracy approaches 80%. Transmittance data was found by comparing the light beam before and after passing the window film. The light intensity measuring unit was deleted by splitting the light source into two beams through a beam splitter. The light beam was changed into resistance by a NORP12 LDR sensor designed at a circuit of voltage divider rule of Khirchoff's laws. This conversion system will produce light beam intensity received by the sensor to become an equal voltage. This voltage will, then, be presented on the computer screen in the form of a real time graph via a 2.0 USB data transfer.

  4. Application of smart transmitter technology in nuclear engineering measurements

    International Nuclear Information System (INIS)

    Kang, Hyun Gook; Seong, Poong Hyun

    1993-01-01

    By making use of the microprocessor technology, instrumentation system becomes intelligent. In this study a programmable smart transmitter is designed and applied to the nuclear engineering measurements. In order to apply the smart transmitter technology to nuclear engineering measurements, the digital time delay compensation function and water level change detection function are developed and applied in this work. The time compensation function compensates effectively the time delay of the measured signal, but it is found that the characteristics of the compensation function should be considered through its application. It is also found that the water level change detection function reduces the detection time to about 7 seconds by the signal processing which has the time constant of over 250 seconds and which has the heavy noise. (Author)

  5. Atmospheric Transmittance/Radiance: Computer Code LOWTRAN 6

    Science.gov (United States)

    1983-08-01

    1966) The refractive index of air, Metrologia 2:12, ൞ -1...sight. For an optical path traversing N layers in an upward or downward direction this process gives N [ 7 A+M A -SCAT --SUN I e,ps+op > AIV < La ... a...for cirrus normal transmittance, r, of the form = exp - (0. 14 LA ) (49) This expression closely duplicates the double exponential model of Davis 4 0 for

  6. Effects of satellite transmitters on captive and wild mallards

    Science.gov (United States)

    Kesler, Dylan C.; Raedeke, Andrew H.; Foggia, Jennifer R.; Beatty, William S.; Webb, Elisabeth B.; Humburg, Dale D.; Naylor, Luke W.

    2014-01-01

    Satellite telemetry has become a leading method for studying large-scale movements and survival in birds, yet few have addressed potential effects of the larger and heavier tracking equipment on study subjects. We simultaneously evaluated effects of satellite telemetry equipment on captive and wild mallards (Anas platyrhynchos) to assess impacts on behavior, body mass, and movement. We randomly assigned 55 captive ducks to one of 3 treatment groups, including a standard body harness group, a modified harness group, and a control group. Ducks in the control group were not fitted with equipment, whereas individuals in the other 2 groups were fitted with dummy transmitters attached with a Teflon ribbon harness or with a similar harness constructed of nylon cord. At the conclusion of the 14-week captive study, mean body mass of birds in the control group was 40–105 g (95% CI) greater than birds with standard harnesses, and 28–99 g (95% CI) greater than birds with modified harnesses. Further, results of focal behavior observations indicated ducks with transmitters were less likely to be in water than control birds. We also tested whether movements of wild birds marked with a similar Teflon harness satellite transmitter aligned with population movements reported by on-the-ground observers who indexed local abundances of mid-continent mallards throughout the non-breeding period. Results indicated birds marked with satellite transmitters moved concurrently with the larger unmarked population. Our results have broad implications for field research and suggest that investigators should consider potential for physiological and behavioral effects brought about by tracking equipment. Nonetheless, results from wild ducks indicate satellite telemetry has the potential to provide useful movement data.

  7. Anomalous Faraday effect of a system with extraordinary optical transmittance.

    Science.gov (United States)

    Khanikaev, Alexander B; Baryshev, Alexander V; Fedyanin, Andrey A; Granovsky, Alexander B; Inoue, Mitsuteru

    2007-05-28

    It is shown theoretically that the Faraday rotation becomes anomalously large and exhibits extraordinary behavior near the frequencies of the extraordinary optical transmittance through optically thick perforated metal film with holes filled with a magneto-optically active material. This phenomenon is explained as result of strong confinement of the evanescent electromagnetic field within magnetic material, which occurs due to excitation of the coupled plasmon-polaritons on the opposite surfaces of the film.

  8. Test and evaluation of radioactively contaminated transducers and transmitters

    International Nuclear Information System (INIS)

    Strahm, R.C.

    1983-01-01

    People in the nuclear industries face some unique problems when handling, testing, or examining transducers and transmitters that have been radioactively contaminated. Although many people and organizations, including EG and G Idaho, have performed such work for many years, there are no set, structured approaches or procedures. This paper discusses a disciplined laboratory approach to contaminated transducer testing and evaluation, utilizing equipment and facilities developed specifically for this type of work

  9. FIR Filter of DS-CDMA UWB Modem Transmitter

    Science.gov (United States)

    Kang, Kyu-Min; Cho, Sang-In; Won, Hui-Chul; Choi, Sang-Sung

    This letter presents low-complexity digital pulse shaping filter structures of a direct sequence code division multiple access (DS-CDMA) ultra wide-band (UWB) modem transmitter with a ternary spreading code. The proposed finite impulse response (FIR) filter structures using a look-up table (LUT) have the effect of saving the amount of memory by about 50% to 80% in comparison to the conventional FIR filter structures, and consequently are suitable for a high-speed parallel data process.

  10. Secure Broadcasting with Imperfect Channel State Information at the Transmitter

    KAUST Repository

    Hyadi, Amal; Rezki, Zouheir; Khisti, Ashish; Alouini, Mohamed-Slim

    2015-01-01

    We investigate the problem of secure broadcasting over fast fading channels with imperfect main channel state information (CSI) at the transmitter. In particular, we analyze the effect of the noisy estimation of the main CSI on the throughput of a broadcast channel where the transmission is intended for multiple legitimate receivers in the presence of an eavesdropper. Besides, we consider the realistic case where the transmitter is only aware of the statistics of the eavesdropper’s CSI and not of its channel’s realizations. First, we discuss the common message transmission case where the source broadcasts the same information to all the receivers, and we provide an upper and a lower bounds on the ergodic secrecy capacity. For this case, we show that the secrecy rate is limited by the legitimate receiver having, on average, the worst main channel link and we prove that a non-zero secrecy rate can still be achieved even when the CSI at the transmitter is noisy. Then, we look at the independent messages case where the transmitter broadcasts multiple messages to the receivers, and each intended user is interested in an independent message. For this case, we present an expression for the achievable secrecy sum-rate and an upper bound on the secrecy sum-capacity and we show that, in the limit of large number of legitimate receivers K, our achievable secrecy sum-rate follows the scaling law log((1−) log(K)), where is the estimation error variance of the main CSI. The special cases of high SNR, perfect and no-main CSI are also analyzed. Analytical derivations and numerical results are presented to illustrate the obtained expressions for the case of independent and identically distributed Rayleigh fading channels.

  11. Mechanisms of light transmittance changes in rat spinal cord slices

    Czech Academy of Sciences Publication Activity Database

    Vargová, Lýdia; Kubinová, Šárka; Syková, Eva

    2002-01-01

    Roč. 1, č. 1 (2002), s. S36 ISSN 0894-1491. [European Meeting on Glia l Cell Function in Health and Disease /5./. Rome - Italy, 21.05.2002-25.05.2002] R&D Projects: GA MŠk LN00A065 Institutional research plan: CEZ:AV0Z5039906; CEZ:MSM 111100004; CEZ:MSM 5011112 Keywords : light transmittance changes Subject RIV: FH - Neurology Impact factor: 4.600, year: 2002

  12. Laser Transmitters for the optical link systems used in CMS

    CERN Multimedia

    Maximilien Brice

    2005-01-01

    In the CMS experiment of the now new flagship LHC optical links will be used for the tracker readout system. One part of this components will be semiconductor laser (~50.000 !!!), named correctly: 1310 nm InGaAsP (DCPBH-MQW) edge-emitting laser. They are foreseen as transmitter in the Tx Hybrid part of the optical link system.

  13. Intraperitoneal implantation of life-long telemetry transmitters in otariids

    Directory of Open Access Journals (Sweden)

    Haulena Martin

    2008-12-01

    Full Text Available Abstract Background Pinnipeds, including many endangered and declining species, are inaccessible and difficult to monitor for extended periods using externally attached telemetry devices that are shed during the annual molt. Archival satellite transmitters were implanted intraperitoneally into four rehabilitated California sea lions (Zalophus californianus and 15 wild juvenile Steller sea lions (Eumetopias jubatus to determine the viability of this surgical technique for the deployment of long-term telemetry devices in otariids. The life history transmitters record information throughout the life of the host and transmit data to orbiting satellites after extrusion following death of the host. Results Surgeries were performed under isoflurane anesthesia and single (n = 4 or dual (n = 15 transmitters were inserted into the ventrocaudal abdominal cavity via an 8.5 to 12 cm incision along the ventral midline between the umbilicus and pubic symphysis or preputial opening. Surgeries lasted 90 minutes (SD = 8 for the 19 sea lions. All animals recovered well and were released into the wild after extended monitoring periods from 27 to 69 days at two captive animal facilities. Minimum post-implant survival was determined via post-release tracking using externally attached satellite transmitters or via opportunistic re-sighting for mean durations of 73.7 days (SE = 9.0, Z. californianus and 223.6 days (SE = 71.5, E. jubatus. Conclusion The low morbidity and zero mortality encountered during captive observation and post-release tracking periods confirm the viability of this surgical technique for the implantation of long-term telemetry devices in otariids.

  14. Secure Broadcasting with Imperfect Channel State Information at the Transmitter

    KAUST Repository

    Hyadi, Amal

    2015-11-13

    We investigate the problem of secure broadcasting over fast fading channels with imperfect main channel state information (CSI) at the transmitter. In particular, we analyze the effect of the noisy estimation of the main CSI on the throughput of a broadcast channel where the transmission is intended for multiple legitimate receivers in the presence of an eavesdropper. Besides, we consider the realistic case where the transmitter is only aware of the statistics of the eavesdropper’s CSI and not of its channel’s realizations. First, we discuss the common message transmission case where the source broadcasts the same information to all the receivers, and we provide an upper and a lower bounds on the ergodic secrecy capacity. For this case, we show that the secrecy rate is limited by the legitimate receiver having, on average, the worst main channel link and we prove that a non-zero secrecy rate can still be achieved even when the CSI at the transmitter is noisy. Then, we look at the independent messages case where the transmitter broadcasts multiple messages to the receivers, and each intended user is interested in an independent message. For this case, we present an expression for the achievable secrecy sum-rate and an upper bound on the secrecy sum-capacity and we show that, in the limit of large number of legitimate receivers K, our achievable secrecy sum-rate follows the scaling law log((1−) log(K)), where is the estimation error variance of the main CSI. The special cases of high SNR, perfect and no-main CSI are also analyzed. Analytical derivations and numerical results are presented to illustrate the obtained expressions for the case of independent and identically distributed Rayleigh fading channels.

  15. 21 CFR 870.2910 - Radiofrequency physiological signal transmitter and receiver.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiofrequency physiological signal transmitter... Devices § 870.2910 Radiofrequency physiological signal transmitter and receiver. (a) Identification. A radiofrequency physiological signal transmitter and receiver is a device used to condition a physiological signal...

  16. 46 CFR 308.522 - Collateral deposit fund, letter of transmittal, Form MA-302.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 8 2010-10-01 2010-10-01 false Collateral deposit fund, letter of transmittal, Form MA... Collateral deposit fund, letter of transmittal, Form MA-302. The standard form of letter of transmittal for use in establishing a collateral deposit fund, may be obtained from the American War Risk Agency or...

  17. Effects of radio transmitters on the behavior of Red-headed Woodpeckers

    Science.gov (United States)

    Mark Vukovich; John C. Kilgo

    2009-01-01

    Previous studies have revealed that radio-transmitters may affect bird behaviors, including feeding rates, foraging behavior, vigilance, and preening behavior. In addition, depending on the method of attachment, transmitters can potentially affect the ability of cavity-nesting birds to use cavities. Our objective was to evaluate effects of transmitters on the behavior...

  18. Transmittance and scattering during wound healing after refractive surgery

    Science.gov (United States)

    Mar, Santiago; Martinez-Garcia, C.; Blanco, J. T.; Torres, R. M.; Gonzalez, V. R.; Najera, S.; Rodriguez, G.; Merayo, J. M.

    2004-10-01

    Photorefractive keratectomy (PRK) and laser in situ keratomileusis (LASIK) are frequent techniques performed to correct ametropia. Both methods have been compared in their way of healing but there is not comparison about transmittance and light scattering during this process. Scattering in corneal wound healing is due to three parameters: cellular size and density, and the size of scar. Increase in the scattering angular width implies a decrease the contrast sensitivity. During wound healing keratocytes activation is induced and these cells become into fibroblasts and myofibroblasts. Hens were operated using PRK and LASIK techniques. Animals used in this experiment were euthanized, and immediately their corneas were removed and placed carefully into a cornea camera support. All optical measurements have been done with a scatterometer constructed in our laboratory. Scattering measurements are correlated with the transmittance -- the smaller transmittance is the bigger scattering is. The aim of this work is to provide experimental data of the corneal transparency and scattering, in order to supply data that they allow generate a more complete model of the corneal transparency.

  19. Fast Turn-off Mine Transient Electromagnetic Transmitter System

    Directory of Open Access Journals (Sweden)

    ZHENG Xiao-Liang

    2014-05-01

    Full Text Available For solving problems such as short turn-off time, high linear degree of falling edge, measurement of turn-off time and influence of primary signals for transient electromagnetic transmitter, and restrictions because of the environmental conditions of underground coal mine, this thesis aims at designing a new transient electromagnetic transmitter system suitable for coal mine. Supported by damping absorption circuit, such system applies small volume, sectional transmitting coil, with features of short turn-off time, high linear degree of current falling edge. It uses the transmitter monitoring circuit, which accurately measures turn-off time and simultaneously records the current value changes after turn-off, thus to eliminate the influence of primary field as well as to restore earlier secondary field signals for reference and finally to improve the ability to detect the shallow structure. It turns out that the new system has a shorter turn-off time, a higher linear degree of current falling and more accurate data record of turn-off current.

  20. Reliability analysis for new technology-based transmitters

    Energy Technology Data Exchange (ETDEWEB)

    Brissaud, Florent, E-mail: florent.brissaud.2007@utt.f [Institut National de l' Environnement Industriel et des Risques (INERIS), Parc Technologique Alata, BP 2, 60550 Verneuil-en-Halatte (France); Universite de Technologie de Troyes (UTT), Institut Charles Delaunay (ICD) and STMR UMR CNRS 6279, 12 rue Marie Curie, BP 2060, 10010 Troyes cedex (France); Barros, Anne; Berenguer, Christophe [Universite de Technologie de Troyes (UTT), Institut Charles Delaunay (ICD) and STMR UMR CNRS 6279, 12 rue Marie Curie, BP 2060, 10010 Troyes cedex (France); Charpentier, Dominique [Institut National de l' Environnement Industriel et des Risques (INERIS), Parc Technologique Alata, BP 2, 60550 Verneuil-en-Halatte (France)

    2011-02-15

    The reliability analysis of new technology-based transmitters has to deal with specific issues: various interactions between both material elements and functions, undefined behaviours under faulty conditions, several transmitted data, and little reliability feedback. To handle these particularities, a '3-step' model is proposed, based on goal tree-success tree (GTST) approaches to represent both the functional and material aspects, and includes the faults and failures as a third part for supporting reliability analyses. The behavioural aspects are provided by relationship matrices, also denoted master logic diagrams (MLD), with stochastic values which represent direct relationships between system elements. Relationship analyses are then proposed to assess the effect of any fault or failure on any material element or function. Taking these relationships into account, the probabilities of malfunction and failure modes are evaluated according to time. Furthermore, uncertainty analyses tend to show that even if the input data and system behaviour are not well known, these previous results can be obtained in a relatively precise way. An illustration is provided by a case study on an infrared gas transmitter. These properties make the proposed model and corresponding reliability analyses especially suitable for intelligent transmitters (or 'smart sensors').

  1. Leptin's effect on taste bud calcium responses and transmitter secretion.

    Science.gov (United States)

    Meredith, Tricia L; Corcoran, Alan; Roper, Stephen D

    2015-05-01

    Leptin, a peptide hormone released by adipose tissue, acts on the hypothalamus to control cravings and appetite. Leptin also acts to decrease taste responses to sweet substances, though there is little detailed information regarding where leptin acts in the taste transduction cascade. The present study examined the effects of leptin on sweet-evoked responses and neuro transmitter release from isolated taste buds. Our results indicate that leptin moderately decreased sweet-evoked calcium mobilization in isolated mouse taste buds. We also employed Chinese hamster ovary biosensor cells to examine taste transmitter release from isolated taste buds. Leptin reduced ATP and increased serotonin release in response to sweet stimulation. However, leptin has no effect on bitter-evoked transmitter release, further showing that the action of leptin is sweet specific. Our results support those of previous studies, which state that leptin acts on taste tissue via the leptin receptor, most likely on Type II (Receptor) cells, but also possibly on Type III (Presynaptic) cells. © The Author 2014. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  2. Aging characteristics of nuclear plant RTDs and pressure transmitters

    International Nuclear Information System (INIS)

    Hashemian, H.M.

    2004-01-01

    Resistance Temperature Detectors (RTDs) and pressure, level, and flow transmitters provide almost all the vital signals that are used for the control and safety of nuclear power plants. Therefore, it is crucial to ensure that the performance of these sensors remain acceptable as they age in the process under normal operating conditions. Four comprehensive research projects were conducted for the U.S. Nuclear Regulatory Commission (NRC) to evaluate the effects of normal aging on calibration stability and response time of RTDs and pressure transmitters of the types used for safety-related measurements in nuclear power plants. Each project was conducted over a three year period. The projects involved laboratory testing of representative RTDs and pressure transmitters aged in simulated reactor conditions. The main purpose of these projects was to establish the degradation rate of the sensors and use the information to determine if the current testing intervals practiced by the nuclear power industry are adequate for management of aging of the sensors. The results have indicated that the current nuclear industry practice of testing the response time and calibration of the sensors once every fuel cycle is adequate. (author)

  3. Transmitter-induced glycogenolysis and gluconeogenesis in leech segmental ganglia.

    Science.gov (United States)

    Pennington, A J; Pentreath, V W

    1987-01-01

    1. The utilization and control of glycogen stores were studied in the isolated segmental ganglia of the horse leech, Haemopis sanguisuga. The glycogen in the ganglia was extracted and assayed fluorimetrically and its cellular localization and turnover studied by autoradiography in conjunction with [3H] glucose. 2. The glycogen levels were measured after incubation with different neurotransmitters for 60 min at 28 degrees C. The results for each experimental ganglion were compared to a paired control ganglion, and the results analysed by paired t-tests. 3. Several transmitter substances (5-HT, octopamine, dopamine, noradrenaline, histamine) produced reductions in glycogen (glycogenolysis); other transmitters (glutamate, GABA) produced increases in glycogen (gluconeogenesis); others (adenosine, glycine) produced reductions or increases, depending on concentration. Acetylcholine had no effect on the glycogen levels. 4. Most of the glycogen in the ganglia is localized in the packet glial cells, which surround the neuron perikarya. Autoradiographic analysis demonstrated that the effects of histamine and dopamine were principally on the glycogen in the glial cells. 5. Adenylate cyclase was demonstrated by electron microscope histochemistry to be localized on the plasma membranes of the glial cells, and to a lesser extent on the neuronal membranes. 6. It is concluded that the changes in glycogen in the glial cells may be party controlled by transmitters via adenylate cyclase. This may provide a sensitive mechanism for coupling neuronal activity with energy metabolism.

  4. Transmittance and Tunneling Current through a Trapezoidal Barrier under Spin Polarization Consideration

    Science.gov (United States)

    Noor, F. A.; Nabila, E.; Mardianti, H.; Ariani, T. I.; Khairurrijal

    2018-04-01

    The transmittance and tunneling current in heterostructures under spin polarization consideration were studied by employing a zinc-blended structure for the heterostructures. An electron tunnels through a potential barrier by applying a bias voltage to the barrier, which is called the trapezoidal potential barrier. In order to study the transmittance, an Airy wave function approach was employed to find the transmittance. The obtained transmittance was then utilized to compute the tunneling current by using a Gauss quadrature method. It was shown that the transmittances were asymmetric with the incident angle of the electron. It was also shown that the tunneling currents increased as the bias voltage increased.

  5. Trans-obturator vaginal tape (TOT) for female stress incontinence: one year follow-up in 120 patients.

    Science.gov (United States)

    Roumeguère, Thierry; Quackels, Th; Bollens, R; de Groote, A; Zlotta, A; Bossche, M Vanden; Schulman, C

    2005-11-01

    The aim of this study was to evaluate the effectiveness of a new minimally invasive surgical procedure, the Trans-obturator Vaginal Tape (TOT) in the treatment of female urodynamic stress incontinence (USI) and to analyse functional results and quality of life after one year of follow up. 120 consecutive women with stress urinary incontinence underwent the procedure since February 2002 under general or loco-regional anesthesia. Minimum follow up was one year (range 12-30 months). Mean age was 58 years (range 31-86). 70% of the patients had pure USI. 5 patients were previously operated for USI. In 10 cases, concomitant repair of pelvic floor defects was mandatory. Collection of the data included operative time, pre- and post-operative complications. Patients were post-operatively assessed at one week, one month and one year. A validated urinary incontinence-specific measure of Quality of Life (QoL) questionnaire (Contilife) was sent and completed 12 months after surgery. The mean operative time was 12 min (range 6-30) with a catheterisation time of 0,9 day (range 0-2). No severe bleeding was observed. There were 13 minor lateral tears of the vagina without any sequelae. Three perforations of the urethra and one of the bladder occurred during the learning phase. In two cases a re-intervention was necessary for tape removal when the injury was not recognised during the procedure. Two transient urinary retention needed a supra pubic catheter and tape release. Eleven women presented transient voiding outflow obstruction. After one month, 93% patients were cured with no pad and a negative cough test with a full bladder. Uroflowmetry did not show any significant changes between pre- and post-operative time in all the population. De novo urgency occurred only in 2.5% and persistent dysuria (Qmax 120 cc) in 4%. 80% of patients were completely dry after one year and 12% were greatly improved. According to the pre-operative maximal urethral closure pressure, continence rate

  6. Retention and effects of miniature transmitters in juvenile American eels

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Robert P.; Janak, Jill; Liss, Stephanie A.; Brown, Richard S.; Deng, Zhiqun; Harnish, Ryan A.

    2017-11-01

    This study was conducted to assess the effects of a non-functional acoustic micro transmitter (tag) on survival, tag loss, and swimming ability of juvenile American eels (Anguilla rostrata). The transmitter was designed for implantation through a < 3 mm opening into the body cavity of anguilliform fishes without the need for sutures. American eels used for the swimming performance study were 113–175 mm (N = 120). There were two treatment groups (tagged and non-tagged), each treatment was split into six size groups of 10 mm for testing. Potential transmitter effects on swimming performance were examined by comparing critical swimming speeds (Ucrit an index of prolonged swimming performance) for tagged and non-tagged eels. There was no significant difference in Ucrit between tagged and non-tagged eels for all of the size groups tested. Median Ucrits for tagged eels ranged from 50.2 cm/s for the smallest group tested (113–119 mm) to 63.9 cm/s for fish 141–150 mm in length. Non-tagged group median Ucrits ranged from 47.2 cm/s for the smallest group to 66.9 cm/s for the 141–150 mm group. An additional 26 eels (115–208 mm) were tagged and held for 38 d (without undergoing swimming performance tests) to determine the effects on survival and tag loss. There was no mortality during the holding period and the majority of the tag loss occurred after 20 days post-tagging, which is the current projected life of the tag. Our results indicate that micro acoustic tags can be successfully implanted in juvenile American eels with no apparent impacts to swimming ability, and would be a viable option for examining eel movement patterns in river systems and near hydroelectric facilities.

  7. Observations of the transmittance in two solar ponds

    Energy Technology Data Exchange (ETDEWEB)

    Almanza, R.; Bryant, M.C.

    1983-11-01

    A NaCl salt gradient solar pond has been in continuous operation at the University of New Mexico since the fall of 1975; a smaller pond, using KNO/sub 3/ to produce the salinity gradient, was commissioned in the fall of 1981. The distribution of absorbed radiation in the ponds is of key importance in the determination of their efficiencies for collecting and storing solar energy. The absorption coefficient of light in an aqueous solution is very dependent upon wavelength; the spectral distribution of sunlight shifts toward the blue and the amount of solar energy absorbed per unit length of path declines with depth of penetration. The presence of suspended solids and bioforms further complicate the transmittance of sun light through the pond, specially since this contamination tends to vary strongly with depth. Because of its importance to the phytoplankton population , considerable work has been done by oceanographers on the absorption and scattering of light for different wavelengths. However, in a solar pond the big question is the amount of energy reaching the lower convective layer (storage). Several attempts have been made to measure the transmittance in solar ponds, mainly NaCl but the problem is to find a temperature-insensitive submersible pyranometer. Convenient formulas have been offered for the attenuation of solar radiation in pond water by considering it to be divided into spectral bands, or by fitting simple analytical functions, or specifying the extintion coefficient. (For the first method, it is necessary to know the absorption and scattering of light for different lambda.) In this paper some measurements of transmittance in the UNM ponds, are presented thereby exhibiting a simple procedure which may be of interest to others in this field.

  8. Method for transmittance measurements in sunglasses for a kiosk

    Science.gov (United States)

    Mello, Marcio M.; Figueiredo, M.; Konda, R. A.; Ventura, Liliane

    2013-03-01

    Light transmittance measurements through sunglasses lenses is one of the required tests of the Brazilian Standard NBR15111(2004). Its measurement establishes the category of the sample and determines the required ultraviolet, visible and infrared protection, as well as the attenuation coefficient for signal light recognition. However, these measurements are usually performed by spectrophotometers and educated users, who are acknowledged to manage the equipment, use the weighting functions (WF) and interpret the data. We propose an alternative method, which consists in having matching optics and electronics to obtain a close WF to be used in transmittance measurements, and create an accessible device, for public self-use, providing a simple way for measuring and educating the public about sunglasses protection. Measurements were made in 30 samples for UV test, performed for the 280 - 400nm range, where UVA and UVB light sources and two photodiode sensors with Erythema action response are assembled, and for traffic signal a visible light sensor was used with spectral human eye response and different LEDs. As for the visible test, the visible light sensor was used for different light sources: incandescent, fluorescent, and a set of LEDs, while the infrared test is performed by several LEDs that provide the 780 - 2000nm range, and an infrared sensor. For these tests, only the samples spectrum were used. The transmittances were within the deviation limit required by NBR15111. The results have led us to build a self service kiosk for public use providing the category, UV protection and IR protection of the sunglasses as well as the information regarding its use for driving.

  9. Behavioral modelling and predistortion of wideband wireless transmitters

    CERN Document Server

    Ghannouchi, Fadhel M; Helaoui, Mohamed

    2015-01-01

    Covers theoretical and practical aspects related to the behavioral modelling and predistortion of wireless transmitters and power amplifiers. It includes simulation software that enables the users to apply the theory presented in the book. In the first section, the reader is given the general background of nonlinear dynamic systems along with their behavioral modelling from all its aspects. In the second part, a comprehensive compilation of behavioral models formulations and structures is provided including memory polynomial based models, box oriented models such as Hammerstein-based and Wiene

  10. The Gigabit Optical Transmitters for the LHCb Calorimeters

    CERN Document Server

    Lax, Ignazio; D’Antone, I; Marconi, U

    2007-01-01

    This report presents the boards developed for the optical data transmission of the calorimeter system of the LHCb experiment and test results. We developed two types of transmission boards: the single-channel and the multi-channel ones. Multi-channel boards can be equipped with a variable number of transmitters, depending on the need, with a maximum allowed of 12 channels. Each optical channel allows transmitting 32 bit data at 40.08 MHz. The boards have been designed and built using radiation hard devices produced at CERN. The optical links have been qualified using the eye diagram and the BERT at 1.6Gbps.

  11. Laser transmitter for Lidar In-Space Technology Experiment

    Science.gov (United States)

    Chang, John; Cimolino, Marc; Petros, Mulugeta

    1991-01-01

    The Lidar In-Space Technology Experiment (LITE) Laser Transmitter Module (LTM) flight laser optical architecture has been space qualified by extensive testing at the system, subsystem and component level. The projected system output performance has been verified using an optically and electrically similar breadboard version of the laser. Parasitic lasing was closely examined and completely suppressed after design changes were implemented and tested. Oscillator and amplifier type heads were separately tested to 150 million shots. Critical subassemblies have undergone environmental testing to Shuttle qualification levels. A superior three color anti-reflection coating was developed and tested for use on 14 surfaces after the final amplifier.

  12. The Casimir effect for pistons with transmittal boundary conditions

    Science.gov (United States)

    Fucci, Guglielmo

    2017-11-01

    This work focuses on the analysis of the Casimir effect for pistons subject to transmittal boundary conditions. In particular we consider, as piston configuration, a direct product manifold of the type I × N where I is a closed interval of the real line and N is a smooth compact Riemannian manifold. By utilizing the spectral zeta function regularization technique, we compute the Casimir energy of the system and the Casimir force acting on the piston. Explicit results for the force are provided when the manifold N is a d-dimensional sphere.

  13. Predicting ambient aerosol thermal-optical reflectance (TOR) measurements from infrared spectra: extending the predictions to different years and different sites

    Science.gov (United States)

    Reggente, Matteo; Dillner, Ann M.; Takahama, Satoshi

    2016-02-01

    Organic carbon (OC) and elemental carbon (EC) are major components of atmospheric particulate matter (PM), which has been associated with increased morbidity and mortality, climate change, and reduced visibility. Typically OC and EC concentrations are measured using thermal-optical methods such as thermal-optical reflectance (TOR) from samples collected on quartz filters. In this work, we estimate TOR OC and EC using Fourier transform infrared (FT-IR) absorbance spectra from polytetrafluoroethylene (PTFE Teflon) filters using partial least square regression (PLSR) calibrated to TOR OC and EC measurements for a wide range of samples. The proposed method can be integrated with analysis of routinely collected PTFE filter samples that, in addition to OC and EC concentrations, can concurrently provide information regarding the functional group composition of the organic aerosol. We have used the FT-IR absorbance spectra and TOR OC and EC concentrations collected in the Interagency Monitoring of PROtected Visual Environments (IMPROVE) network (USA). We used 526 samples collected in 2011 at seven sites to calibrate the models, and more than 2000 samples collected in 2013 at 17 sites to test the models. Samples from six sites are present both in the calibration and test sets. The calibrations produce accurate predictions both for samples collected at the same six sites present in the calibration set (R2 = 0.97 and R2 = 0.95 for OC and EC respectively), and for samples from 9 of the 11 sites not included in the calibration set (R2 = 0.96 and R2 = 0.91 for OC and EC respectively). Samples collected at the other two sites require a different calibration model to achieve accurate predictions. We also propose a method to anticipate the prediction error; we calculate the squared Mahalanobis distance in the feature space (scores determined by PLSR) between new spectra and spectra in the calibration set. The squared Mahalanobis distance provides a crude method for assessing the

  14. [Meta-analysis of clinical efficacy of TVT-S versus TVT-O/TOT in the treatment of stress urinary incontinence].

    Science.gov (United States)

    Zhou, Quan; Song, Yan-feng; Chen, Jie; Qiu, Lin-lin; Yuan, Xiao-dong

    2012-10-09

    To assess the current evidence of effectiveness and safety of Single-incision mini-slings (TVT-S) versus transobturator tension-free vaginal tapes (TVT-O/TOT) in the management of female stress urinary incontinence (SUI). Literature searches were conducted for all randomized controlled trials (RCTs) comparing TVT-S and TVT-O/TOT from CNKI, CBM, VIP, MEDLINE, OVID, FMJS and Cochrane Library between November 1996 and November 2011. The Revman 5.1.0 software was used for Meta-analysis according to Cochrane system evaluation method. A total of 1545 females in 7 RCTs were included. Meta-analysis showed that no statistical differences existed in the rate of postoperative voiding dysfunction and dyspareunia between TVT-S and TVT-O/TOT (P > 0.05). But the rate of objective cure, re-operation, inner thigh and groin pain and de novo urgency were statistically significant (P TVT-O/TOT, TVT-S procedure is associated with less postoperative inner thigh and groin pain, but a lower objective cure rate and relatively higher rates of de novo urgency and re-operation.

  15. Factors and Competences for Business Process Management Systems implementation : Factoren en Competenties met betrekking tot de Implementatie van Business Process Management Systemen

    NARCIS (Netherlands)

    Pascal Ravesteijn

    2011-01-01

    De markt voor Business Process Management (BPM) software groeit razend snel. Voor 2010 wordt er een marktomvang voorspeld van tussen de 1 tot 6 miljard dollar, dit betekend dat deze markt sinds 2005 meer dan verdubbeld is. BPM krijgt ook in toenemende mate publiciteit in de markt echter dan gaat het

  16. Suomi NPP VIIRS solar diffuser screen transmittance model and its applications.

    Science.gov (United States)

    Lei, Ning; Xiong, Xiaoxiong; Mcintire, Jeff

    2017-11-01

    The visible infrared imaging radiometer suite on the Suomi National Polar-orbiting Partnership satellite calibrates its reflective solar bands through observations of a sunlit solar diffuser (SD) panel. Sunlight passes through a perforated plate, referred to as the SD screen, before reaching the SD. It is critical to know whether the SD screen transmittance measured prelaunch is accurate. Several factors such as misalignments of the SD panel and the measurement apparatus could lead to errors in the measured transmittance and thus adversely impact on-orbit calibration quality through the SD. We develop a mathematical model to describe the transmittance as a function of the angles that incident light makes with the SD screen, and apply the model to fit the prelaunch measured transmittance. The results reveal that the model does not reproduce the measured transmittance unless the size of the apertures in the SD screen is quite different from the design value. We attribute the difference to the orientation alignment errors for the SD panel and the measurement apparatus. We model the alignment errors and apply our transmittance model to fit the prelaunch transmittance to retrieve the "true" transmittance. To use this model correctly, we also examine the finite source size effect on the transmittance. Furthermore, we compare the product of the retrieved "true" transmittance and the prelaunch SD bidirectional reflectance distribution function (BRDF) value to the value derived from on-orbit data to determine whether the prelaunch SD BRDF value is relatively accurate. The model is significant in that it can evaluate whether the SD screen transmittance measured prelaunch is accurate and help retrieve the true transmittance from the transmittance with measurement errors, consequently resulting in a more accurate sensor data product by the same amount.

  17. Modified Polar Sigma-Delta Transmitter for Multiradio Applications

    Directory of Open Access Journals (Sweden)

    Maršálek Roman

    2010-01-01

    Full Text Available Radio transmitters capable of transforming variable envelope signals into constant envelope signals can be associated with high-efficiency switched mode power amplifiers. One of the techniques providing this conversion is Polar Sigma-Delta ( architecture. This approach provides efficient solution for high-dynamic signals, and, moreover, it offers flexibility in a multiradio environment. The overall concept of the polar transmitter is presented here along with novel modifications and improvements. Namely, when recombining the envelope and the phase signals, it is suggested to replace the analog mixing by a digital mixing. The impact of a frequency synthesizer with a switched loop bandwidth and its imperfections on the overall polar architecture is investigated as well. The Mobile WiMAX standard has been chosen for validation due to very high requirements in terms of power dynamics and the variable channel bandwidth. Simulation results are presented in this paper, and advantages and drawbacks of this novel approach are pointed here as well.

  18. Evaluation of Photopolymerization Kinetics by Means of Transmittance Measurements

    Science.gov (United States)

    Bovesecchi, G.; Coppa, P.; Armellin, E.; Cerroni, L.

    2018-04-01

    Polymeric resins are widely used for dental reconstruction, and most resins use camphorquinone as activator of the polymerization reaction, through the absorption of light at a defined wavelength range (from 400 nm to 460 nm). During the photopolymerization curing, transparency of these resins changes and transmittance variation can be detected by photodiode and bolometer measurements. This change can be used as an index of the reaction rate, and the kinetic parameter k (reaction rate) can be evaluated from transmittance data by means of nonlinear regression. The relation between k and the light intensity impinging on the resin sample can thus be obtained. In the present work, tests were carried out using the resin Enamel Plus HFO GE2. Results reveal the presence of two different polymerization reactions at two different intensity ranges. The obtained k values were used to predict the most suited curing times for different light intensities. The proposed methodology can be applied to different dental reconstruction materials, provided that the material is partially transparent and that its transparency changes during the polymerization reaction.

  19. Fiber-based laser MOPA transmitter packaging for space environment

    Science.gov (United States)

    Stephen, Mark; Yu, Anthony; Chen, Jeffrey; Numata, Kenji; Wu, Stewart; Gonzales, Brayler; Han, Lawrence; Fahey, Molly; Plants, Michael; Rodriguez, Michael; Allan, Graham; Abshire, James; Nicholson, Jeffrey; Hariharan, Anand; Mamakos, William; Bean, Brian

    2018-02-01

    NASA's Goddard Space Flight Center has been developing lidar to remotely measure CO2 and CH4 in the Earth's atmosphere. The ultimate goal is to make space-based satellite measurements with global coverage. We are working on maturing the technology readiness of a fiber-based, 1.57-micron wavelength laser transmitter designed for use in atmospheric CO2 remote-sensing. To this end, we are building a ruggedized prototype to demonstrate the required power and performance and survive the required environment. We are building a fiber-based master oscillator power amplifier (MOPA) laser transmitter architecture. The laser is a wavelength-locked, single frequency, externally modulated DBR operating at 1.57-micron followed by erbium-doped fiber amplifiers. The last amplifier stage is a polarization-maintaining, very-large-mode-area fiber with 1000 μm2 effective area pumped by a Raman fiber laser. The optical output is single-frequency, one microsecond pulses with >450 μJ pulse energy, 7.5 KHz repetition rate, single spatial mode, and < 20 dB polarization extinction.

  20. Regulatory Experience on Safety Smart Transmitter's CCF of SKN 3 and 4

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Y. M.; Jeong, C. H. [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2014-10-15

    Smart transmitters are digital I and C equipment which can replace analog transmitters. Non safety grade smart transmitters have been used for I and C systems of NPP(Nuclear Power Plant).. But, recently, smart transmitters have been used for safety grade I and C systems as well as non-safety grade I and C system for SKN 3 and 4. Smart transmitters execute measuring sensor values, generating output signals and adjusting range using software. Also, smart transmitters are basically capable of remote calibration through digital communication. The operating capability is more reliable and effective with remote calibration of smart transmitters, but there is potential vulnerability that causes the result no one wanted such as cyber attacks or software CCF. This paper addresses our regulatory experiences how to evaluate safety smart transmitter's CCF of SKN 3 and 4. Nuclear I and C equipment have increased the use on digital technology in safety system. According that, interest in a postulated software CCF is increasing. The software may be firmware or operating system of digital equipment. During SKN 3 and 4 operating license process, safety grade smart transmitter's adequacy was reviewed such as software V and V processes and equipment qualification. Also, it was analyzed that effect of the software CCFs of smart transmitters under DBA condition. Main concern was whether the postulated smart transmitter's software CCF may lead to an adverse safety consequence. We have future research plan to execute proof tests about our concerns and develop regulatory guide for smart transmitters.

  1. Optimal transmitter power of an intersatellite optical communication system with reciprocal Pareto fading.

    Science.gov (United States)

    Liu, Xian

    2010-02-10

    This paper shows that optical signal transmission over intersatellite links with swaying transmitters can be described as an equivalent fading model. In this model, the instantaneous signal-to-noise ratio is stochastic and follows the reciprocal Pareto distribution. With this model, we show that the transmitter power can be minimized, subject to a specified outage probability, by appropriately adjusting some system parameters, such as the transmitter gain.

  2. All polymer chip for amperometric studies of transmitter release from large groups of neuronal cells

    DEFF Research Database (Denmark)

    Larsen, Simon T.; Taboryski, Rafael

    2012-01-01

    We present an all polymer electrochemical chip for simple detection of transmitter release from large groups of cultured PC 12 cells. Conductive polymer PEDOT:tosylate microelectrodes were used together with constant potential amperometry to obtain easy-to-analyze oxidation signals from potassium......-induced release of transmitter molecules. The nature of the resulting current peaks is discussed, and the time for restoring transmitter reservoirs is studied. The relationship between released transmitters and potassium concentration was found to fit to a sigmoidal dose–response curve. Finally, we demonstrate...

  3. Effects of aging on calibration and response time of nuclear plant pressure transmitters

    International Nuclear Information System (INIS)

    Hashemian, H.M.

    1991-01-01

    This paper presents the key results of an experimental research project conducted for the Nuclear Regulatory Commission to quantify the effects of normal aging on static and dynamic performance of nuclear grade pressure, level, and flow transmitters (hereafter referred to as pressure transmitters). The project involved laboratory testing of representative pressure transmitters manufactured by Barton, Foxboro, Rosemount, and Tobar (or Veritrak) companies. These manufacturers provide the four most commonly used pressure transmitters in the safety systems of US nuclear power plants. The transmitters were tested under normal aging conditions as opposed to accelerated aging, even though accelerated aging will be used in the last few months of the project to determine the weak links and failure modes of the transmitters. The project has been performed in two phases. The Phase 1 project which was a six month feasibility study has been completed and the results published in NUREG/CR-5383. The Phase 2 project is still underway with the final report due in the fall of 1991. The project has focused on the following areas: (1) effects of aging on calibration stability; (2) effects of aging on response time; (3) study of individual components of pressure transmitters that are sensitive to aging degradation; (4) sensing line blockages due to solidification of boron, formation of sludge, freezing, and other effects; (5) search of licensee event reports and component reliability databases for failures of safety-related pressure transmitters; and (6) oil loss syndrome in Rosemount pressure transmitters

  4. Electromagnetic Cavity Effects from Transmitters Inside a Launch Vehicle Fairing

    Science.gov (United States)

    Trout, Dawn H.; Wahid, Parveen F.; Stanley, James E.

    2009-01-01

    This paper provides insight into the difficult analytical issue for launch vehicles and spacecraft that has applicability outside of the launch industry. Radiation from spacecraft or launch vehicle antennas located within enclosures in the launch vehicle generates an electromagnetic environment that is difficult to accurately predict. This paper discusses the test results of power levels produced by a transmitter within a representative scaled vehicle fairing model and provides preliminary modeling results at the low end of the frequency test range using a commercial tool. Initially, the walls of the fairing are aluminum and later, layered with materials to simulate acoustic blanketing structures that are typical in payload fairings. The effects of these blanketing materials on the power levels within the fairing are examined.

  5. Effect of transmitter turn-off time on transient soundings

    Science.gov (United States)

    Fitterman, D.V.; Anderson, W.L.

    1987-01-01

    A general procedure for computing the effect of non-zero turn-off time on the transient electromagnetic response is presented which can be applied to forward and inverse calculation methods for any transmitter-receiver configuration. We consider in detail the case of a large transmitter loop which has a receiver coil located at the center of the loop (central induction or in-loop array). For a linear turn-off ramp of width t0, the voltage response is shown to be the voltage due to an ideal step turn-off averaged over windows of width t0. Thus the effect is similar to that obtained by using averaging windows in the receiver. In general when time zero is taken to be the end of the ramp, the apparent resistivity increases for a homogeneous half-space over a limited time range. For time zero taken to be the start of the ramp the apparent resistivity is affected in the opposite direction. The effect of the ramp increases with increasing t0 and first-layer resistivity, is largest during the intermediate stage, and decreases with increasing time. It is shown that for a ramp turn-off, there is no effect in the early and late stages. For two-layered models with a resistive first layer (??1>??2), the apparent resistivity is increased in the intermediate stage. When the first layer is more conductive than the second layer (??1interpretation as shown by field examples; the influence is the greatest on near-surface layer parameters. ?? 1987.

  6. Mixed garnet laser crystals for water vapour DIAL transmitter

    Science.gov (United States)

    Treichel, Rainer; Czeranowsky, Christoph; Ileri, Bilge; Petermann, Klaus; Huber, Günter

    2017-11-01

    There are more or less well established technologies such as the optical-parametric-oscillator (OPO), the Raman-laser, and the Ti-Sapphire laser, which are able to emit laser light in the region of the water vapour absorption lines. For WALES the regions of about 935 nm, 942 nm, and 944 nm have been identified as the most suitable wavelength ranges. However, each of these laser designs is highly sophisticated. Current baseline for WALES is the Ti-Sapphire laser. A fourth possibility to achieve these wavelength ranges is to shift the groundstate laser lines (938 nm and 946 nm) of the Nd:YAG laser by replacing Aluminium and Yttrium by other rare earth elements. Changes of the host lattice characteristics lead to a shift of the upper and lower laser levels. These modified crystals are summarized under the name of "Mixed Garnet" crystals. Only the Mixed Garnet lasers can be pumped directly with diode laser and use a direct approach to generate the required laser pulses without frequency conversion. Therefore no additional non-linear crystals are needed and a higher electric to optical efficiency is expected as well as single frequency operation using spectral tuning elements like etalons. Such lasers have the great potential to fulfil the requirements and to become the preferred transmitter concept for WALES as well as for follow up missions. Within a ESA study several crystal compositions have been grown, spectrally characterised and analysed. Absorbed space radiation energy in the crystal lattice causes colour centres, which can reabsorb the pump and laser wavelength and consequently reduce the laser gain considerably. Co-dopants such as Chromium and Cerium are able to suppress the colour centres and are candidates for effective radiation hardening. The results of the crystal tuning, the co-doping with different radiation hardeners and the radiation tests will be presented. There applicability for a space based water vapour DIAL transmitter will be discussed.

  7. Feasibility of coupling a thermal/optical carbon analyzer to a quadrupole mass spectrometer for enhanced PM2.5 speciation.

    Science.gov (United States)

    Riggio, Gustavo M; Chow, Judith C; Cropper, Paul M; Wang, Xiaoliang; Yatavelli, Reddy L N; Yang, Xufei; Watson, John G

    2018-05-01

    A thermal/optical carbon analyzer (TOA), normally used for quantification of organic carbon (OC) and elemental carbon (EC) in PM 2.5 (fine particulate matter) speciation networks, was adapted to direct thermally evolved gases to an electron impact quadrupole mass spectrometer (QMS), creating a TOA-QMS. This approach produces spectra similar to those obtained by the Aerodyne aerosol mass spectrometer (AMS), but the ratios of the mass to charge (m/z) signals differ and must be remeasured using laboratory-generated standards. Linear relationships are found between TOA-QMS signals and ammonium (NH 4 + ), nitrate (NO 3 - ), and sulfate (SO 4 2- ) standards. For ambient samples, however, positive deviations are found for SO 4 2- , compensated by negative deviations for NO 3 - , at higher concentrations. This indicates the utility of mixed-compound standards for calibration or separate calibration curves for low and high ion concentrations. The sum of the QMS signals across all m/z after removal of the NH 4 + , NO 3 - , and SO 4 2- signals was highly correlated with the carbon content of oxalic acid (C₂H₂O₄) standards. For ambient samples, the OC derived from the TOA-QMS method was the same as the OC derived from the standard IMPROVE_A TOA method. This method has the potential to reduce complexity and costs for speciation networks, especially for highly polluted urban areas such as those in Asia and Africa. Ammonium, nitrate, and sulfate can be quantified by the same thermal evolution analysis applied to organic and elemental carbon. This holds the potential to replace multiple parallel filter samples and separate laboratory analyses with a single filter and a single analysis to account for a large portion of the PM 2.5 mass concentration.

  8. Effect of package light transmittance on vitamin content of milk. Part 2: UHT whole milk

    NARCIS (Netherlands)

    Saffert, A.; Pieper, G.; Jetten, J.

    2008-01-01

    This work is the second part of a milk study evaluating the effect of package light transmittance on the vitamin content of milk, in this case on UHT whole milk. The milk was stored at three different light intensities in polyethylene terephthalate (PET) bottles with varying light transmittance as

  9. Photonic integrated multiwavelength transmitters for fiber-to-the-home networks

    NARCIS (Netherlands)

    Lawniczuk, K.; Smit, M.K.; Piramidowicz, P.; Szczepanski, P.; Leijtens, X.J.M.; Wale, M.J.

    2012-01-01

    In this paper we present measurement results of monolithically integrated photonic transmitters for application in the next generation Fiber-to-the-Home (FTTH) networks. 4- and 8-channel transmitters were integrated onto a single chip, using multiple lasers with distributed Bragg reflector (DBR)

  10. 31 CFR 537.323 - U.S. registered money transmitter.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false U.S. registered money transmitter. 537.323 Section 537.323 Money and Finance: Treasury Regulations Relating to Money and Finance... General Definitions § 537.323 U.S. registered money transmitter. The term U.S. registered money...

  11. 31 CFR 538.319 - U.S. registered money transmitter.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false U.S. registered money transmitter. 538.319 Section 538.319 Money and Finance: Treasury Regulations Relating to Money and Finance... General Definitions § 538.319 U.S. registered money transmitter. The term U.S. registered money...

  12. 2-Micron Laser Transmitter for Coherent CO2 DIAL Measurement

    Science.gov (United States)

    Singh, Upendra N.; Bai, Yingxin; Yu, Jirong

    2009-01-01

    Carbon dioxide (CO2) has been recognized as one of the most important greenhouse gases. It is essential for the study of global warming to accurately measure the CO2 concentration in the atmosphere and continuously record its variation. A high repetition rate, highly efficient, Q-switched 2-micron laser system as the transmitter of a coherent differential absorption lidar for CO2 measurement has been developed in NASA Langley Research Center. This laser system is capable of making a vertical profiling of CO2 from ground and column measurement of CO2 from air and space-borne platform. The transmitter is a master-slave laser system. The master laser operates in a single frequency, either on-line or off-line of a selected CO2 absorption line. The slave laser is a Q-switched ring-cavity Ho:YLF laser which is pumped by a Tm:fiber laser. The repetition rate can be adjusted from a few hundred Hz to 10 kHz. The injection seeding success rate is from 99.4% to 99.95%. For 1 kHz operation, the output pulse energy is 5.5mJ with the pulse length of 50 ns. The optical-to-optical efficiency is 39% when the pump power is 14.5W. A Ho:YLF laser operating in the range of 2.05 micrometers can be tuned over several characteristic lines of CO2 absorption. Experimentally, a diode pumped Ho:Tm:YLF laser has been successfully used as the transmitter of coherent differential absorption lidar for the measurement of CO2 with a repetition rate of 5 Hz and pulse energy of 75 mJ. For coherent detection, high repetition rate is required for speckle averaging to obtain highly precise measurements. However, a diode pumped Ho:Tm:YLF laser can not operate in high repetition rate due to the large heat loading and up-conversion. A Tm:fiber laser pumped Ho:YLF laser with low heat loading can operate in high repetition rate. A theoretical model has been established to simulate the performance of Tm:fiber laser pumped Ho:YLF lasers. For continuous wave (CW) operation, high pump intensity with small beam

  13. Identification of a mitochondrial target of thiazolidinedione insulin sensitizers (mTOT--relationship to newly identified mitochondrial pyruvate carrier proteins.

    Directory of Open Access Journals (Sweden)

    Jerry R Colca

    Full Text Available Thiazolidinedione (TZD insulin sensitizers have the potential to effectively treat a number of human diseases, however the currently available agents have dose-limiting side effects that are mediated via activation of the transcription factor PPARγ. We have recently shown PPARγ-independent actions of TZD insulin sensitizers, but the molecular target of these molecules remained to be identified. Here we use a photo-catalyzable drug analog probe and mass spectrometry-based proteomics to identify a previously uncharacterized mitochondrial complex that specifically recognizes TZDs. These studies identify two well-conserved proteins previously known as brain protein 44 (BRP44 and BRP44 Like (BRP44L, which recently have been renamed Mpc2 and Mpc1 to signify their function as a mitochondrial pyruvate carrier complex. Knockdown of Mpc1 or Mpc2 in Drosophila melanogaster or pre-incubation with UK5099, an inhibitor of pyruvate transport, blocks the crosslinking of mitochondrial membranes by the TZD probe. Knockdown of these proteins in Drosophila also led to increased hemolymph glucose and blocked drug action. In isolated brown adipose tissue (BAT cells, MSDC-0602, a PPARγ-sparing TZD, altered the incorporation of (13C-labeled carbon from glucose into acetyl CoA. These results identify Mpc1 and Mpc2 as components of the mitochondrial target of TZDs (mTOT and suggest that understanding the modulation of this complex, which appears to regulate pyruvate entry into the mitochondria, may provide a viable target for insulin sensitizing pharmacology.

  14. Training for Future Esp Trainers: Evaluating the Training of Trainers (TOT Program in Labuan Bajo, Manggarai Barat, Flores

    Directory of Open Access Journals (Sweden)

    Irfan Rifai

    2013-04-01

    Full Text Available By cooperating with Yayasan Komodo Kita and Mandiri Bank, English department of Binus University was chiefly in charge of a 15 day Training Of Trainers (TOT program for 24 participants prepared for teaching English in Labuan Bajo, Flores. The training was aimed to prepare already fluent- in – English- teachers, tour guides, and university graduates with the right tools and method in teaching English. To assess the program, a set of evaluation questionnaire was given to the participants to know their responses on the training material, the trainers, and the program by using Likert’s scale type questions. An observational record was also used as a tool to measure participants’ achievement. The questionnaire reveals that the participants respond positively to the program and the material and favor the approaches made by the trainers during the training. However, the training shows various results in participants’ performance. It is assumed that the non teaching background of the majority of participants and the level of English as two key factors influencing their performance.  

  15. Transmittance of young Norway spruce stand canopy for photosynthetically active radiation during the growing season

    International Nuclear Information System (INIS)

    Markova, I.; Kubasek, J.

    2013-01-01

    Analysis of transmittance of young Norway spruce stand canopy for photosynthetically active radiation (PAR) was made at the study site of Bily Kriz (the Moravian-Silesian Beskids Mts., the Czech Republic) at different sky conditions during the growing season in 2010. For the description of PAR transmittance different phenological phases of the spruce stand development in clear and overcast days were chosen. The mean daily PAR transmittance of the spruce canopy was significantly higher in overcast days compared with clear ones. Diffuse PAR thus penetrated into lower parts of the canopy more efficiently than direct one. PAR transmittance of young Norway spruce stand canopy was different in individual phenological phases of the spruce stand canopy which was caused by changes in the stand structure during the growing season. Thus monitoring of transmittance of young Norway spruce stand canopy for PAR can help to describe the development of spruce stand canopy

  16. Flat-topped beam transmittance in anisotropic non-Kolmogorov turbulent marine atmosphere

    Science.gov (United States)

    Ata, Yalçın; Baykal, Yahya

    2017-10-01

    Turbulence affects optical propagation, and, as a result, the intensity is attenuated along the path of propagation. The attenuation becomes significant when the turbulence becomes stronger. Transmittance is a measure indicating how much power is collected at the receiver after the optical wave propagates in the turbulent medium. The on-axis transmittance is formulated when a flat-topped optical beam propagates in a marine atmosphere experiencing anisotropic non-Kolmogorov turbulence. Variations in the transmittance are evaluated versus the beam source size, beam number, link distance, power law exponent, anisotropy factor, and structure constant. It is found that larger beam source sizes and beam numbers yield higher transmittance values; however, as the link distance, power law exponent, anisotropy factor, or structure constant increase, transmittance values are lowered. Our results will help in the performance evaluations of optical wireless communication and optical imaging systems operating in a marine atmosphere.

  17. Case note: HR (zaaknr. 13/04255: interregionaal recht; art. 38 lid 3 Statuut; interregionale bevoegdheid rechter i.g.v. verzoek tot nihilstelling alimentatie; overeenkomstige toepassing IPR-bevoegdheidsrecht; voorrang verdragen en EU-verordeningen in interregionale gevallen)

    NARCIS (Netherlands)

    de Boer, Th.M.

    2014-01-01

    Interregionaal recht; art. 38 lid 3 Statuut; interregionale bevoegdheid rechter i.g.v. verzoek tot nihilstelling alimentatie; overeenkomstige toepassing IPR-bevoegdheidsrecht; voorrang verdragen en EU-verordeningen in interregionale gevallen. Overeenkomstige toepassing Verordening (EG) nr. 4/2009

  18. Pressure transmitter surveillance: the dominant real pole case

    International Nuclear Information System (INIS)

    Blazquez, J.; Ballestrin, J.

    1995-01-01

    There are about 500 pressure transmitters in a nuclear power plant. Due to Safety requirements, some of them must be specially surveilled. Sensor response time to a pressure ramp is the usual quantity to be measured. Response time, τ r , reflects the dynamics of the sensor and the sensing line. A real pole is due to the inner sensor structure, but the complex pole stands for the sensing line too. The real pole usually is the dominant in most sensors. On line monitoring noise analysis regards simultaneously both, the sensor and the sensing line, but the noise signal contains not only the sensor poles, but many others coming from the plant, so must be conditioned previously and the determination of τ r is not free of systematic errors. That is the price to be paid for non disturbing the plant. When the real pole is dominant, the sensing line contribution is negligible, so the on line noise monitoring methods are supported by the laboratory experiments and the real pole border in the PSD is properly identified. The mean square frequency results proportional to τ r -1 , so manual techniques are designed for response time surveillance made by non noise plant's maintenance technicians. (author)

  19. Radiation Exposure Monitoring and Information Transmittal (REMIT) system

    International Nuclear Information System (INIS)

    Cale, R.; Clark, T.; Dixson, R.; Hagemeyer, D.

    1993-06-01

    The Radiation Exposure Monitoring and Information Transmittal (REMIT) system is designed to assist US Nuclear Regulatory Commission (NRC)licensees in meeting the reporting requirements of the revised 10 CFR 20 and in agreement with the guidance contained in R.G. 8.7, Rev. 1, ''Instructions for Recording and Reporting Occupational Exposure Data.'' REMIT is a personal computer (PC) based menu driven system that facilitates the manipulation of data base files to record and report radiation exposure information. REMIT is designed to be user-friendly and contains the full text of R. G. 8.7, Rev. 1, on-line as well as context-sensitive help throughout the program. The user can enter data directly from NRC Forms 4 or 5, REMIT allows the user to view the individual's exposure in relation to regulatory or administrative limits and alerts the user to exposures in excess of these limits. The system also provides for the calculation and summation of dose from intakes and the determination of the dose to the maximally exposed extremity for the monitoring year. REMIT can produce NRC Forms 4 and 5 in paper and electronic format and can import/export data from ASCII and data base files

  20. Reflection effects in multimode fiber systems utilizing laser transmitters

    Science.gov (United States)

    Bates, Harry E.

    1991-11-01

    A number of optical communication lines are now in use at NASA-Kennedy for the transmission of voice, computer data, and video signals. Now, all of these channels use a single carrier wavelength centered near 1300 or 1550 nm. Engineering tests in the past have given indications of the growth of systematic and random noise in the RF spectrum of a fiber network as the number of connector pairs is increased. This noise seems to occur when a laser transmitter is used instead of a LED. It has been suggested that the noise is caused by back reflections created at connector fiber interfaces. Experiments were performed to explore the effect of reflection on the transmitting laser under conditions of reflective feedback. This effort included computer integration of some of the instrumentation in the fiber optic lab using the Lab View software recently acquired by the lab group. The main goal was to interface the Anritsu Optical and RF spectrum analyzers to the MacIntosh II computer so that laser spectra and network RF spectra could be simultaneously and rapidly acquired in a form convenient for analysis. Both single and multimode fiber is installed at Kennedy. Since most are multimode, this effort concentrated on multimode systems.

  1. Comparison between moving and stationary transmitter systems in induction logging

    Science.gov (United States)

    Poddar, M.; Caleb Dhanasekaran, P.; Prabhakar Rao, K.

    1985-09-01

    In a general treatment of the theory of induction logging, an exact integral representation has been obtained for the mutual impedance between a vertical dipole transmitter and a coaxial dipole receiver in a three layered earth. Based on this representation, a computer model has been devised using the traditional Slingram system of induction logging and the comparatively new Turam system, ignoring borehole effects. The model results indicate that due to its much larger response, the Turam system is in general preferable to the Slingram in mineral and groundwater investigations where formation conductivity much less than 1 S/m is generally encountered. However, if the surrounding media are conductive (more than 0.1 S/m), the Turam system suffers from large amplitude attenuation and phase rotation of the primary field caused by the conductive surrounding, and is less useful than the Slingram system which does not so suffer, unless the target bed is shallow. Because it is a more complex function of system parameters than the corresponding Slingram log, a Turam log can be conveniently interpreted only by the modern inverse method using a fast algorithm for the forward solution and a high speed digital computer.

  2. Computational Investigations of THz Transmittance in the Atmosphere

    Directory of Open Access Journals (Sweden)

    Yang Xingyu

    2016-01-01

    Full Text Available With the recent scientific advancements in Terahertz (THz wave propagation and reception technology, there has been significant development in new possibilities for using THz waves – offering new possibilities in THz detection and ranging. A first foundational step toward this goal is to better understand THz transmittance in the turbulent atmosphere. In this project, a frequency modulation pattern of THz waves was created by utilizing a system of shifting frequency based on temperature, air humidity, and distance of transmission. The total path loss of the wave in air, based on the wave spread and molecular absorption, was then modeled using radiative transfer theory, onto a set of JavaHAWK filtered-HITRAN data representative of an air sample. This data was used to generate a path loss matrix, which was then used to optimize frequency of transmission for the specific conditions. The concept to be evaluated is whether adaptive frequency modulated THz might usefully decrease transmission losses by adjusting to atmospheric conditions (such as local variations in temperature and humidity.

  3. A 7T spine array based on electric dipole transmitters.

    Science.gov (United States)

    Duan, Qi; Nair, Govind; Gudino, Natalia; de Zwart, Jacco A; van Gelderen, Peter; Murphy-Boesch, Joe; Reich, Daniel S; Duyn, Jeff H; Merkle, Hellmut

    2015-10-01

    The goal of this study was to explore the feasibility of using an array of electric dipole antennas for RF transmission in spine MRI at high fields. A two-channel transmit array based on an electric dipole design was quantitatively optimized for 7T spine imaging and integrated with a receive array combining eight loop coils. Using B1+ mapping, the transmit efficiency of the dipole array was compared with a design using quadrature loop pairs. The radiofrequency energy deposition for each array was measured using a home-built dielectric phantom and MR thermometry. The performance of the proposed array was qualitatively demonstrated in human studies. The results indicate dramatically improved transmit efficiency for the dipole design compared with the loop excitation. A gain of up to 76% was achieved within the spinal region. For imaging of the spine, electric dipole-based transmitters provide an attractive alternative to the traditional loop-based design. Easy integration with existing receive array technology facilitates practical use at high fields. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.

  4. Evaluation of the carbon content of aerosols from the burn- ing of biomass in the Brazilian Amazon using thermal, op- tical and thermal-optical analysis methods

    Energy Technology Data Exchange (ETDEWEB)

    Soto-Garcia, Lydia L.; Andreae, Meinrat O.; Andreae, Tracey W.; taxo, Paulo Ar-; Maenhaut, Willy; Kirchstetter, Thomas; Novakov, T.; Chow, Judith C.; Mayol-Bracero, Olga L.

    2011-06-03

    Aerosol samples were collected at a pasture site in the Amazon Basin as part of the project LBA-SMOCC-2002 (Large-Scale Biosphere-Atmosphere Experiment in Amazonia - Smoke Aerosols, Clouds, Rainfall and Climate: Aerosols from Biomass Burning Perturb Global and Regional Climate). Sampling was conducted during the late dry season, when the aerosol composition was dominated by biomass burning emissions, especially in the submicron fraction. A 13-stage Dekati low-pressure impactor (DLPI) was used to collect particles with nominal aerodynamic diameters (D{sub p}) ranging from 0.03 to 0.10 m. Gravimetric analyses of the DLPI substrates and filters were performed to obtain aerosol mass concentrations. The concentrations of total, apparent elemental, and organic carbon (TC, EC{sub a}, and OC) were determined using thermal and thermal-optical analysis (TOA) methods. A light transmission method (LTM) was used to determine the concentration of equivalent black carbon (BC{sub e}) or the absorbing fraction at 880 nm for the size-resolved samples. During the dry period, due to the pervasive presence of fires in the region upwind of the sampling site, concentrations of fine aerosols (D{sub p} < 2.5 {mu}m: average 59.8 {mu}g m{sup -3}) were higher than coarse aerosols (D{sub p} > 2.5 {mu}m: 4.1 {mu}g m{sup -3}). Carbonaceous matter, estimated as the sum of the particulate organic matter (i.e., OC x 1.8) plus BC{sub e}, comprised more than 90% to the total aerosol mass. Concentrations of EC{sub a} (estimated by thermal analysis with a correction for charring) and BCe (estimated by LTM) averaged 5.2 {+-} 1.3 and 3.1 {+-} 0.8 {mu}g m{sup -3}, respectively. The determination of EC was improved by extracting water-soluble organic material from the samples, which reduced the average light absorption {angstrom} exponent of particles in the size range of 0.1 to 1.0 {mu}m from > 2.0 to approximately 1.2. The size-resolved BC{sub e} measured by the LTM showed a clear maximum between 0.4 and

  5. 47 CFR 95.221 - (R/C Rule 21) How do I have my R/C transmitter serviced?

    Science.gov (United States)

    2010-10-01

    ... FCC certificated R/C transmitter (see R/C Rule 9) must be made in accord with the Technical... in order to: (1) Adjust a transmitter to an antenna; (2) Detect or measure radiation of energy other...

  6. Accurate method for luminous transmittance and signal detection quotients measurements in sunglasses lenses

    Science.gov (United States)

    Loureiro, A. D.; Gomes, L. M.; Ventura, L.

    2018-02-01

    The international standard ISO 12312-1 proposes transmittance tests that quantify how dark sunglasses lenses are and whether or not they are suitable for driving. To perform these tests a spectrometer is required. In this study, we present and analyze theoretically an accurate alternative method for performing these measurements using simple components. Using three LEDs and a four-channel sensor we generated weighting functions similar to the standard ones for luminous and traffic lights transmittances. From 89 sunglasses lens spectroscopy data, we calculated luminous transmittance and signal detection quotients using our obtained weighting functions and the standard ones. Mean-difference Tukey plots were used to compare the results. All tested sunglasses lenses were classified in the right category and correctly as suitable or not for driving. The greatest absolute errors for luminous transmittance and red, yellow, green and blue signal detection quotients were 0.15%, 0.17, 0.06, 0.04 and 0.18, respectively. This method will be used in a device capable to perform transmittance tests (visible, traffic lights and ultraviolet (UV)) according to the standard. It is important to measure rightly luminous transmittance and relative visual attenuation quotients to report correctly whether or not sunglasses are suitable for driving. Moreover, standard UV requirements depend on luminous transmittance.

  7. Long-term outcomes of TOT and TVT procedures for the treatment of female stress urinary incontinence: a systematic review and meta-analysis.

    Science.gov (United States)

    Leone Roberti Maggiore, Umberto; Finazzi Agrò, Enrico; Soligo, Marco; Li Marzi, Vincenzo; Digesu, Alex; Serati, Maurizio

    2017-08-01

    One of the most relevant topics in the field of pelvic floor dysfunction treatment is the long-term efficacy of surgical procedures, in particular, the use of prosthesis. Hence, a systematic review and meta-analysis was conducted to evaluate the long-term effectiveness and safety of midurethral sling (MUS) procedures for stress urinary incontinence (SUI), as reported in randomised controlled trials (RCTs) and non-randomised studies. This systematic review is based on material searched and obtained via PubMed/Medline, Scopus, and the Cochrane Library between January 2000 and October 2016. Peer-reviewed, English-language journal articles evaluating the long-term (≥5 years) efficacy and safety of MUS in women affected by SUI were included. A total of 5,592 articles were found after the search, and excluding duplicate publications, 1,998 articles were available for the review process. Among these studies, 11 RCTs (0.6%) and 5 non-RCTs (0.3%) could be included in the qualitative and quantitative synthesis. Objective and subjective cumulative cure rates for retropubic technique (TVT) and transobturator tape (TOT; both out-in and in-out) were 61.6% (95% CI: 58.5-64.8%) and 76.5% (95% CI: 73.8-79.2%), and 64.4% (95% CI: 61.4-67.4%) and 81.3% (95% CI: 78.9-83.7%) respectively. When considering TOT using the out-in technique (TOT-OI) and TOT using the in-out technique (TVT-O) the objective and subjective cumulative cure rates were 57.2% (95% CI: 53.7-60.7%) and 81.6% (95% CI: 78.8-84.4%), and 68.8% (95% CI: 64.9-72.7%) and 81.3% (95% CI: 77.9-84.7%) respectively. Furthermore, this article demonstrates that both TVT and TOT are associated with similar long-term objectives (OR: 0.87 [95% CI: 0.49-1.53], I 2  = 67%, p = 0.62) and subjective (OR: 0.84 [95% CI: 0.46-1.55], I 2  = 68%, p = 0.58) cure rates. Similarly, no significant difference has been observed between TTOT-OI and TVT-O) in objective (OR: 3.03 [95% CI: 0.97-9.51], I 2  = 76%, p = 0

  8. The Use of a Solid State Analog Television Transmitter as a Superconducting Electron Gun Power Amplifier

    Energy Technology Data Exchange (ETDEWEB)

    J.G. Kulpin, K.J. Kleman, R.A. Legg

    2012-07-01

    A solid state analog television transmitter designed for 200 MHz operation is being commissioned as a radio frequency power amplifier on the Wisconsin superconducting electron gun cavity. The amplifier consists of three separate radio frequency power combiner cabinets and one monitor and control cabinet. The transmitter employs rugged field effect transistors built into one kilowatt drawers that are individually hot swappable at maximum continuous power output. The total combined power of the transmitter system is 33 kW at 200 MHz, output through a standard coaxial transmission line. A low level radio frequency system is employed to digitally synthesize the 200 MHz signal and precisely control amplitude and phase.

  9. Age-related changes in spectral transmittance of the human crystalline lens in situ.

    Science.gov (United States)

    Sakanishi, Yoshihito; Awano, Masakazu; Mizota, Atsushi; Tanaka, Minoru; Murakami, Akira; Ohnuma, Kazuhiko

    2012-01-01

    It was the aim of this study to measure spectral transmission of the human crystalline lens in situ. The crystalline lens was illuminated by one of four light-emitting diodes of different colors. The relative spectral transmittance of the human crystalline lens was measured with the Purkinje-Sanson mirror images over a wide range of ages. The study evaluated 36 crystalline lenses of 28 subjects aged 21-76 years. There was a significant correlation between the age and spectral transmittance for blue light. Spectral transmittance of the crystalline lens in situ could be measured with Purkinje-Sanson mirror images. Copyright © 2012 S. Karger AG, Basel.

  10. Ciguatoxin enhances quantal transmitter release from frog motor nerve terminals.

    Science.gov (United States)

    Molgó, J.; Comella, J. X.; Legrand, A. M.

    1990-01-01

    1. Ciguatoxin (CTX), a marine toxin produced by the benthic dinoflagellate Gambierdiscus toxicus, is responsible for a complex endemic disease in man known as ciguatera fish poisoning. In the present study we have investigated the effects of purified CTX extracted for Gymnothorax javanicus moray-eel liver on frog isolated neuromuscular preparations with conventional electrophysiological techniques. 2. CTX (1-2.5 nM) applied to cutaneous pectoris nerve-muscle preparations induced, after a short delay, spontaneous fibrillations of the muscle fibres that could be suppressed with 1 microM tetrodotoxin (TTX) or by formamide to uncouple excitation-contraction. 3. In preparations treated with formamide, CTX (1-2.5 nM) caused either spontaneous or repetitive muscle action potentials (up to frequencies of 60-100 Hz) in response to a single nerve stimulus. Recordings performed at extrajunctional regions of the muscle membrane revealed that during the repetitive firing a prolongation of the repolarizing phase of the action potential occurred. At junctional sites the repetitive action potentials were triggered by repetitive endplate potentials (e.p.ps). 4. CTX (2.5 nM) caused a TTX-sensitive depolarization of the muscle membrane. 5. In junctions equilibrated in solutions containing high Mg2+ + low Ca2+, addition of CTX (1.5 nM) first induced an average increase of 239 +/- 36% in the mean quantal content of e.p.ps. Subsequently CTX reduced and finally blocked nerve-evoked transmitter release irreversibly. 6. CTX (1.5-2.5 nM) increased the frequency of miniature endplate potentials (m.e.p.ps) in junctions bathed either in normal Ringer, low Ca2(+)-high Mg2+ medium or in a nominally Ca2(+)-free solution containing EGTA.2+ Extensive washing with toxin-free solutions did not reverse the effect.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:1972891

  11. Toward maximum transmittance into absorption layers in solar cells: investigation of lossy-film-induced mismatches between reflectance and transmittance extrema.

    Science.gov (United States)

    Chang, Yin-Jung; Lai, Chi-Sheng

    2013-09-01

    The mismatch in film thickness and incident angle between reflectance and transmittance extrema due to the presence of lossy film(s) is investigated toward the maximum transmittance design in the active region of solar cells. Using a planar air/lossy film/silicon double-interface geometry illustrates important and quite opposite mismatch behaviors associated with TE and TM waves. In a typical thin-film CIGS solar cell, mismatches contributed by TM waves in general dominate. The angular mismatch is at least 10° in about 37%-53% of the spectrum, depending on the thickness combination of all lossy interlayers. The largest thickness mismatch of a specific interlayer generally increases with the thickness of the layer itself. Antireflection coating designs for solar cells should therefore be optimized in terms of the maximum transmittance into the active region, even if the corresponding reflectance is not at its minimum.

  12. Optimal power allocation of a single transmitter-multiple receivers channel in a cognitive sensor network

    KAUST Repository

    Ayala Solares, Jose Roberto; Rezki, Zouheir; Alouini, Mohamed-Slim

    2012-01-01

    The optimal transmit power of a wireless sensor network with one transmitter and multiple receivers in a cognitive radio environment while satisfying independent peak, independent average, sum of peak and sum of average transmission rate constraints

  13. Design and calculation of low infrared transmittance and low emissivity coatings for heat radiative applications

    Science.gov (United States)

    Wang, Guang-Hai; Zhang, Yue; Zhang, Da-Hai; Fan, Jin-Peng

    2012-02-01

    The infrared transmittance and emissivity of heat-insulating coatings pigmented with various structural particles were studied using Kubelka-Munk theory and Mie theory. The primary design purpose was to obtain the low transmittance and low emissivity coatings to reduce the heat transfer by thermal radiation for high-temperature applications. In the case of silica coating layers constituted with various structural titania particles (solid, hollow, and core-shell spherical), the dependence of transmittance and emissivity of the coating layer on the particle structure and the layer thickness was investigated and optimized. The results indicate that the coating pigmented with core-shell titania particles exhibits a lower infrared transmittance and a lower emissivity value than that with other structural particles and is suitable to radiative heat-insulating applications.

  14. Performance Limits of Online Energy Harvesting Communications with Noisy Channel State Information at the Transmitter

    KAUST Repository

    Zenaidi, Mohamed Ridha; Rezki, Zouheir; Alouini, Mohamed-Slim

    2017-01-01

    to mobility and environmental changes. In this paper, we consider the problem of power allocation taking into account the energy arrivals over time and the quality of channel state information (CSI) measured at the transmitter, in order to maximize

  15. Solid State Transmitters for Water Vapor and Ozone DIAL Systems, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — We have developed a common architecture for laser transmitters that address requirements for water vapor as well as ground and airborne ozone lidar systems. Our...

  16. Standard Practice for Calculation of Photometric Transmittance and Reflectance of Materials to Solar Radiation

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1988-01-01

    1.1 This practice describes the calculation of luminous (photometric) transmittance and reflectance of materials from spectral radiant transmittance and reflectance data obtained from Test Method E 903. 1.2 Determination of luminous transmittance by this practice is preferred over measurement of photometric transmittance by methods using the sun as a source and a photometer as detector except for transmitting sheet materials that are inhomogeneous, patterned, or corrugated. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  17. Perturbations of ionosphere-magnetosphere coupling by powerful VLF emissions from ground-based transmitters

    International Nuclear Information System (INIS)

    Belov, A. S.; Markov, G. A.; Ryabov, A. O.; Parrot, M.

    2012-01-01

    The characteristics of the plasma-wave disturbances stimulated in the near-Earth plasma by powerful VLF radiation from ground-based transmitters are investigated. Radio communication VLF transmitters of about 1 MW in power are shown to produce artificial plasma-wave channels (density ducts) in the near-Earth space that originate in the lower ionosphere above the disturbing emission source and extend through the entire ionosphere and magnetosphere of the Earth along the magnetic field lines. Measurements with the onboard equipment of the DEMETER satellite have revealed that under the action of emission from the NWC transmitter, which is one of the most powerful VLF radio transmitters, the generation of quasi-electrostatic (plasma) waves is observed on most of the satellite trajectory along the disturbed magnetic flux tube. This may probably be indicative of stimulated emission of a magnetospheric maser.

  18. Conductive Polymer Microelectrodes for on-chip measurement of transmitter release from living cells

    DEFF Research Database (Denmark)

    Larsen, Simon Tylsgaard; Matteucci, Marco; Taboryski, Rafael J.

    2012-01-01

    driven cell trapping inside closed chip devices. Conductive polymer microelectrodes were used to measure transmitter release using electrochemical methods such as cyclic voltammetry and constant potential amperometry. By measuring the oxidation current at a cyclic voltammogram, the concentration...

  19. Development of Ethernet Based Remote Monitoring and Controlling of MST Radar Transmitters using ARM Cortex Microcontroller

    Directory of Open Access Journals (Sweden)

    Lakshmi Narayana ROSHANNA

    2013-01-01

    Full Text Available The recently emerging Web Services technology has provided a new and excellent solution to Industrial Automation in online control and remote monitoring. In this paper, a Web Service Based Remote Monitoring & Controlling of Radar Transmitters for safety management (WMCT developed for MST Radar is described. It achieved the MST radar transmitters’ remote supervisory, data logging and controlling activities. The system is developed using an ARM Cortex M3 processor to monitor and control the 32 triode-based transmitters of the 53-MHz Radar. The system controls transmitters via the internet using an Ethernet client server and store health status in the Database for radar performance analysis. The system enables scientists to operate and control the radar transmitters from a remote client machine Webpage.

  20. High Performance Design of 100Gb/s DPSK Optical Transmitter

    DEFF Research Database (Denmark)

    Das, Bhagwan; Abdullah, M.F.L; Shah, Nor Shahihda Mohd

    2016-01-01

    and optical transmitter have taken plenty of time for transmitting signal. When proposed design is operated at 1 GHz, 5 GHz, 10 GHz and 20 GHz using time constraint technique, it is observed that among all these frequencies, at 10 GHz high performance output is achieved for designed optical transmitter....... This high performance design of optical transmitter has zero timing error, low timing score and high slack time due to synchronization between input data and clock frequency. It is also determined that 99% timing score is reduced in comparison with 1 GHz frequency that has high jitters, high timing error......, high time score and low slack time. The high performance design is realized without disturbing actual bandwidth, power consumption and other parameters of the design. The proposed high performance design of 100Gb/s optical transmitter can be used with existing optical communication system to develop...

  1. Directional and hemispherical solar energy transmittance of single and double glazing

    NARCIS (Netherlands)

    Nijnatten, van P.A.; Hugot-Le Goff, le A; Granqvist, C.-G.; Lampert, C.M.

    1992-01-01

    Solar and visual light transmittance, color appearance, thermal emissivity, and other optical properties of architectural glazing are in general angular dependent. Realistic computation of solar properties, therefore, requires the angular behavior to be known. Determination of these properties for

  2. Electromagnetic coupling between transmitters and electro-explosive devices located within an enclosure.

    Energy Technology Data Exchange (ETDEWEB)

    Warne, Larry Kevin; Jorgenson, Roy Eberhardt; Coats, Rebecca Sue

    2010-04-01

    This report documents calculations conducted to determine if 42 low-power transmitters located within a metallic enclosure can initiate electro-explosive devices (EED) located within the same enclosure. This analysis was performed for a generic EED no-fire power level of 250 mW. The calculations show that if the transmitters are incoherent, the power available is 32 mW - approximately one-eighth of the assumed level even with several worst-case assumptions in place.

  3. BioRadioTransmitter: a self-powered wireless glucose-sensing system.

    Science.gov (United States)

    Hanashi, Takuya; Yamazaki, Tomohiko; Tsugawa, Wakako; Ikebukuro, Kazunori; Sode, Koji

    2011-09-01

    Although an enzyme fuel cell can be utilized as a glucose sensor, the output power generated is too low to power a device such as a currently available transmitter and operating system, and an external power source is required for operating an enzyme-fuel-cell-based biosensing system. We proposed a novel biosensor that we named BioCapacitor, in which a capacitor serves as a transducer. In this study, we constructed a new BioCapacitor-based system with an added radio-transmitter circuit and a miniaturized enzyme fuel cell. A miniaturized direct-electron-transfer-type compartmentless enzyme fuel cell was constructed with flavin adenine dinucleotide-dependent glucose dehydrogenase complex-based anode and a bilirubin-oxidase-based cathode. For construction of a BioRadioTransmitter wireless sensing system, a capacitor, an ultra-low-voltage charge-pump-integrated circuit, and Hartley oscillator circuit were connected to the miniaturized enzyme fuel cell. A radio-receiver circuit, comprising two field-effect transistors and a coil as an antenna, was used to amplify the signal generated from the biofuel cells. Radio wave signals generated by the BioRadioTransmitter were received, amplified, and converted from alternate to direct current by the radio receiver. When the capacitor discharges in the presence of glucose, the BioRadioTransmitter generates a radio wave, which is monitored by a radio receiver connected wirelessly to the sensing device. Magnitude of the radio wave transmission frequency change observed at the radio receiver was correlated to glucose concentration in the fuel cells. We constructed a stand-alone, self-powered, wireless glucose-sensing system called a BioRadioTransmitter by using a radio transmitter in which the radio wave transmission frequency changes with the glucose concentration in the fuel cell. The BioRadioTransmitter is a significant advance toward construction of an implantable continuous glucose monitor. © 2011 Diabetes Technology Society.

  4. Measurement of soluble solids content in watermelon by Vis/NIR diffuse transmittance technique*

    OpenAIRE

    Tian, Hai-qing; Ying, Yi-bin; Lu, Hui-shan; Fu, Xia-ping; Yu, Hai-yan

    2007-01-01

    Watermelon is a popular fruit in the world with soluble solids content (SSC) being one of the major characteristics used for assessing its quality. This study was aimed at obtaining a method for nondestructive SSC detection of watermelons by means of visible/near infrared (Vis/NIR) diffuse transmittance technique. Vis/NIR transmittance spectra of intact watermelons were acquired using a low-cost commercially available spectrometer operating over the range 350~1000 nm. Spectra data were analyz...

  5. Perancangan Prototipe Transmitter Beacon Black Box Locator Acoustic 37.5 kHz Pingers

    OpenAIRE

    RUSTAMAJI RUSTAMAJI; KANIA SAWITRI; RUDI GUNAWAN

    2016-01-01

    ABSTRAK Pingers transmitter berfungsi untuk memancarkan sinyal atau getaran pulsa akustik pada black box. Frekuensi sinyal yang dipancarkan sebesar 37,5 kHz yang dimodulasikan oleh pulsa dengan durasi 10 ms setiap interval 1 second. Modulasi yang digunakan adalah modulasi on off keying. Dalam penelitian ini dibuat perancangan pingers transmitter yang tersusun atas rangkaian osilator, timer, inverter, switch dan rangkaian amplifier. Frekuensi 37,5 kHz tersebut dibangkitkan oleh rangkaian osi...

  6. Software-Defined Radio Global System for Mobile Communications Transmitter Development for Heterogeneous Network Vulnerability Testing

    Science.gov (United States)

    2013-12-01

    AbdelWahab, “ 2G / 3G Inter-RAT Handover Performance Analysis,” Second European Conference on Antennas and Propagation, pp. 1, 8, 11–16, Nov. 2007. [19] J...RADIO GLOBAL SYSTEM FOR MOBILE COMMUNICATIONS TRANSMITTER DEVELOPMENT FOR HETEROGENEOUS NETWORK VULNERABILITY TESTING by Carson C. McAbee... MOBILE COMMUNICATIONS TRANSMITTER DEVELOPMENT FOR HETEROGENEOUS NETWORK VULNERABILITY TESTING 5. FUNDING NUMBERS 6. AUTHOR(S) Carson C. McAbee

  7. Prediction of transmittance spectra for transparent composite electrodes with ultra-thin metal layers

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Zhao; Alford, T. L., E-mail: TA@asu.edu [School for Engineering of Matter, Transport, and Energy, Arizona State University, Tempe, Arizona 85287 (United States); Khorasani, Arash Elhami [ON Semiconductor Corp., Phoenix, Arizona 85005 (United States); Theodore, N. D. [CHD-Fab, Freescale Semiconductor Inc., Tempe, Arizona 85224 (United States); Dhar, A. [Intel Corp., 2501 NW 229th Ave, Hillsboro, Oregon 97124 (United States)

    2015-11-28

    Recent interest in indium-free transparent composite-electrodes (TCEs) has motivated theoretical and experimental efforts to better understand and enhance their electrical and optical properties. Various tools have been developed to calculate the optical transmittance of multilayer thin-film structures based on the transfer-matrix method. However, the factors that affect the accuracy of these calculations have not been investigated very much. In this study, two sets of TCEs, TiO{sub 2}/Au/TiO{sub 2} and TiO{sub 2}/Ag/TiO{sub 2}, were fabricated to study the factors that affect the accuracy of transmittance predictions. We found that the predicted transmittance can deviate significantly from measured transmittance for TCEs that have ultra-thin plasmonic metal layers. The ultrathin metal layer in the TCE is typically discontinuous. When light interacts with the metallic islands in this discontinuous layer, localized surface plasmons are generated. This causes extra light absorption, which then leads to the actual transmittance being lower than the predicted transmittance.

  8. The deep-tow marine controlled-source electromagnetic transmitter system for gas hydrate exploration

    Science.gov (United States)

    Wang, Meng; Deng, Ming; Wu, Zhongliang; Luo, Xianhu; Jing, Jianen; Chen, Kai

    2017-02-01

    The Marine Controlled-Source Electromagnetic (MCSEM) method has been recognized as an important and effective tool to detect electrically resistive structures, such as oil, gas, and gas hydrate. The MCSEM performance is strongly influenced by the transmitter system design. We have developed a deep-tow MCSEM transmitter system. In this paper, some new technical details will be present. A 10,000 m optical-electrical composite cable is used to support high power transmission and fast data transfer; a new clock unit is designed to keep the synchronization between transmitter and receivers, and mark the time stamp into the transmission current full waveform; a data link is established to monitor the real-time altitude of the tail unit; an online insulation measuring instrument is adopted to monitor current leakage from high voltage transformer; a neutrally buoyant dipole antenna of copper cable and flexible electrodes are created to transmit the large power current into seawater; a new design method for the transmitter, which is called "real-time control technology of hardware parallelism", is described to achieve inverting and recording high-power current waveform, controlling functions, and collecting auxiliary information. We use a gas hydrate exploration test to verify the performance of the transmitter system, focusing on more technical details, rather than applications. The test shows that the transmitter can be used for gas hydrate exploration as an effective source.

  9. Hydrodynamic effect of a satellite transmitter on a juvenile green turtle (Chelonia mydas)

    Science.gov (United States)

    Watson; Granger

    1998-09-01

    Wind tunnel tests were performed to measure the effect of a satellite transmitter on a juvenile green turtle (Chelonia mydas). A full-scale turtle model was constructed from an 11.5 kg specimen with a 48 cm carapace length, and a transmitter model was constructed from a Telonics ST-6. The turtle model was tested in a wind tunnel with and without the transmitter, which was mounted on the forward, topmost part of the carapace. Drag, lift and pitch moment were measured for several speeds and flow angles, and the data were scaled for application to the marine environment. At small flow angles representative of straight-line swimming, the transmitter increased drag by 27-30 %, reduced lift by less than 10 % and increased the pitch moment by 11-42 %. On the basis of the drag data at zero angle of attack, it is estimated that the backpack will reduce swimming speed by 11 %, assuming that the turtle produces the same thrust with the unit attached. The drag data are also used to estimate the effect of a transmitter on the swimming energetics of an adult green turtle. Design guidelines are included to minimize the adverse forces and moments caused by the transmitter.

  10. Effects of radio transmitters on the behavior of Red-headed Woodpeckers.

    Energy Technology Data Exchange (ETDEWEB)

    Vukovich, Mark; Kilgo, John, C.

    2009-05-01

    ABSTRACT. Previous studies have revealed that radio-transmitters may affect bird behaviors, including feeding rates, foraging behavior, vigilance, and preening behavior. In addition, depending on the method of attachment, transmitters can potentially affect the ability of cavity-nesting birds to use cavities. Our objective was to evaluate effects of transmitters on the behavior of and use of cavities byRed-headedWoodpeckers (Melanerpes erythrocephalus). Using backpack harnesses, we attached 2.1-g transmitter packages that averaged 3.1% of body weight (range = 2.5–3.6%) to Red-headed Woodpeckers. We observed both radio-tagged (N = 23) and nonradio-tagged (N = 28) woodpeckers and determined the percentage of time spent engaged in each of five behaviors: flight, foraging, perching, preening, and territorial behavior. We found no difference between the two groups in the percentage of time engaged in each behavior. In addition, we found that transmitters had no apparent effect on use of cavities for roosting by radio-tagged woodpeckers (N = 25).We conclude that backpack transmitters weighing less than 3.6% of body weight had no impact on either their behavior or their ability to use cavities.

  11. Van dominee tot koopman?

    NARCIS (Netherlands)

    Gorissen, M.M.J.; Heide, van der C.M.; Schaminée, J.H.J.; Ruijs, A.

    2017-01-01

    This report focuses on whether voluntary nature compensation has added value for biodiversity in the
    Netherlands, and on whether habitat banking could be a supplement to the existing Dutch system of
    mandatory nature compensation. In essence, habitat banking is the realisation of nature in

  12. Van Bahrein tot Bitcoin

    NARCIS (Netherlands)

    Lodder, A.R.

    2014-01-01

    Door het internet kan de burger rechtstreeks contact krijgen met zijn publiek zonder hulp van derden als omroepen, kranten, uitgevers, muziekindustrie, etc. Bij al deze communicaties is prominent (Youtube) of minder prominent (Wordpress) een derde partij betrokken die de communicatie faciliteert.

  13. REMIT, Radiation Exposure Monitoring and Information Transmittal System

    International Nuclear Information System (INIS)

    Cale, R.; Clark, T.; Dixson, P.; Hagemeyer, D.; Hardwick, C.; Pippen, H.

    1997-01-01

    1 - Description of program or function: The Radiation Exposure Monitoring and Information Transmittal (REMIT) system is designed to assist U.S. Nuclear Regulatory Commission (NRC) licensees in meeting the reporting requirements of the Revised 10 CFR Part 20 and in agreement with the guidance contained in Regulatory Guide 8.7, Rev.1, Instructions for Recording and Reporting Occupational Exposure Data. REMIT is a personal computer (PC) -based menu driven system that facilitates the manipulation of data base files to record and report radiation exposure information. REMIT is designed to be user-friendly and contains the full text of Regulatory Guide 8.7, Rev.1, on-line as well as context-sensitive help throughout the program. The user can enter data directly from NRC Form 5s or Form 4s. REMIT allows the user to view the individual's exposure in relation to regulatory or administrative limits and will alert the user to exposures in excess of these limits. The system also provides for the calculation and summation of dose from intakes and the determination of the dose to the maximally exposed extremity for the monitoring year. REMIT can produce NRC Form 5s and 4s in paper and electronic format and can import/export data from ASCII and data base files. 2 - Method of solution: REMIT makes use of the dose conversion factors from EPA Report 11 Limiting Values of Radionuclide Intake and Air Concentration and Dose Conversion Factors for Inhalation, Submission, and Ingestion, to calculate the Committed Dose Equivalent to the maximally exposed organ and the committed Effective Dose Equivalent from intakes measured in micro-curies. REMIT also estimates the amount (in micrograms) of uranium intake from the activity entered in micro-curies. This calculation is based on the specific activities of the uranium isotopes. 3 - Restrictions on the complexity of the problem: REMIT is a single- user system that only runs on IBM compatible PC systems under DOS and supports only Hewlett

  14. Device-independent quantum reading and noise-assisted quantum transmitters

    International Nuclear Information System (INIS)

    Roga, W; Buono, D; Illuminati, F

    2015-01-01

    In quantum reading, a quantum state of light (transmitter) is applied to read classical information. In the presence of noise or for sufficiently weak signals, quantum reading can outperform classical reading by reason of enhanced state distinguishability. Here we show that enhanced quantum efficiency depends on the presence in the transmitter of a particular type of quantum correlations, the discord of response. Different encodings and transmitters give rise to different levels of efficiency. Considering noisy quantum probes, we show that squeezed thermal transmitters with non-symmetrically distributed noise among the field modes yield higher quantum efficiency compared with coherent thermal quantum states. The noise-enhanced quantum advantage is a consequence of the discord of response being a non-decreasing function of increasing thermal noise under constant squeezing, a behavior that leads to increased state distinguishability. We finally show that, for non-symmetric squeezed thermal states, the probability of error, as measured by the quantum Chernoff bound, vanishes asymptotically with increasing local thermal noise with finite global squeezing. Therefore, with fixed finite squeezing, noisy but strongly discordant quantum states with a large noise imbalance between the field modes can outperform noisy classical resources as well as pure entangled transmitters with the same finite level of squeezing. (paper)

  15. The Effect of an Externally Attached Neutrally Buoyant Transmitter on Mortal Injury during Simulated Hydroturbine Passage

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Richard S.; Pflugrath, Brett D.; Carlson, Thomas J.; Deng, Zhiqun

    2012-02-03

    On their seaward migration, juvenile salmonids commonly pass hydroelectric dams. Fish passing through hydroturbines experience a rapid decrease in pressure as they pass by the turbine blade and the severity of this decompression can be highly variable. This rapid decrease in pressure can result in injuries such as swim bladder rupture, exophthalmia, and emboli and hemorrhaging in the fins and tissues. However, recent research indicates that the presence of a telemetry tag (acoustic, radio, inductive) implanted inside the coelom of a juvenile salmon increases the likelihood that the fish will be injured or die during turbine passage. Thus, previous research conducted using telemetry tags implanted into the coelom of fish may have been inaccurate. Thus, a new technique is needed to provide unbiased estimates of survival through turbines. This research provides an evaluation of the effectiveness of a neutrally buoyant externally attached acoustic transmitter. Both nontagged fish and fish tagged with a neutrally buoyant external transmitter were exposed to a range of rapid decompressions simulating turbine passage. Juvenile Chinook salmon tagged with a neutrally buoyant externally attached acoustic transmitter did not receive a higher degree of barotrauma than their nontagged counterparts. We suggest that future research include field-based comparisons of survival and behavior among fish tagged with a neutrally buoyant external transmitter and those internally implanted with transmitters.

  16. Glutamate may be an efferent transmitter that elicits inhibition in mouse taste buds.

    Directory of Open Access Journals (Sweden)

    Yijen A Huang

    Full Text Available Recent studies suggest that l-glutamate may be an efferent transmitter released from axons innervating taste buds. In this report, we determined the types of ionotropic synaptic glutamate receptors present on taste cells and that underlie this postulated efferent transmission. We also studied what effect glutamate exerts on taste bud function. We isolated mouse taste buds and taste cells, conducted functional imaging using Fura 2, and used cellular biosensors to monitor taste-evoked transmitter release. The findings show that a large fraction of Presynaptic (Type III taste bud cells (∼50% respond to 100 µM glutamate, NMDA, or kainic acid (KA with an increase in intracellular Ca(2+. In contrast, Receptor (Type II taste cells rarely (4% responded to 100 µM glutamate. At this concentration and with these compounds, these agonists activate glutamatergic synaptic receptors, not glutamate taste (umami receptors. Moreover, applying glutamate, NMDA, or KA caused taste buds to secrete 5-HT, a Presynaptic taste cell transmitter, but not ATP, a Receptor cell transmitter. Indeed, glutamate-evoked 5-HT release inhibited taste-evoked ATP secretion. The findings are consistent with a role for glutamate in taste buds as an inhibitory efferent transmitter that acts via ionotropic synaptic glutamate receptors.

  17. Fiber-Based, Trace-Gas, Laser Transmitter Technology Development for Space

    Science.gov (United States)

    Stephen, Mark; Yu, Anthony; Chen, Jeffrey; Nicholson, Jeffrey; Engin, Doruk; Mathason, Brian; Wu, Stewart; Allan, Graham; Hasselbrack, William; Gonzalez, Brayler; hide

    2015-01-01

    NASA’s Goddard Space Flight Center (GSFC) is working on maturing the technology readiness of a laser transmitter designed for use in atmospheric CO2 remote-sensing. GSFC has been developing an airplane-based CO2 lidar instrument over several years to demonstrate the efficacy of the instrumentation and measurement technique and to link the science models to the instrument performance. The ultimate goal is to make space-based satellite measurements with global coverage. In order to accomplish this, we must demonstrate the technology readiness and performance of the components as well as demonstrate the required power-scaling to make the link with the required signal-to-noise-ratio (SNR). To date, all the instrument components have been shown to have the required performance with the exception of the laser transmitter.In this program we are working on a fiber-based master oscillator power amplifier (MOPA) laser transmitter architecture where we will develop a ruggedized package and perform the relevant environmental tests to demonstrate TRL-6. In this paper we will review our transmitter architecture and progress on the performance and packaging of the laser transmitter.

  18. Application of smart differential pressure transmitters (DPTS) for containment studies facility (CSF)

    International Nuclear Information System (INIS)

    Shanware, V.M.; Gole, N.V.; Sebastian, A.; Subramaniam, K.

    2001-01-01

    Containment Studies Facility (CSF) is being set up in BARC for studying various containment related thermal hydraulic and other processes during simulated conditions of pipe rupture. The set up consists of a model reactor containment vessel with a model primary heat transport system. Besides, provisions exist to introduce aerosols and hydrogen also in the containment model. The instrumentation includes measurement of the process temperatures, pressures, levels, flows, humidity, etc. Differential Pressure Transmitters (DPT) will be used for measurement of levels and flows in the CSF. The procured DPTs for this facility are smart. Conventional transmitters have a rangeability specification of 5 or 6. But the smart transmitters have rangeability varying between 40-100. Smart transmitters have facility to change its operating range online. This enables the provision of zooming in on the selected range and narrowing the range around the point of measurement. This facility can be exploited to realise the maximum possible accuracy at the smallest possible range around the point of measurement. This paper describes how the smart DPTs function, how the Highway Addressable Remote Transmitter (HART) protocol works and how we propose to use the on-line rangeability of these DPTs get the highest resolution in our measurements. (author)

  19. Glutamate may be an efferent transmitter that elicits inhibition in mouse taste buds.

    Science.gov (United States)

    Huang, Yijen A; Grant, Jeff; Roper, Stephen

    2012-01-01

    Recent studies suggest that l-glutamate may be an efferent transmitter released from axons innervating taste buds. In this report, we determined the types of ionotropic synaptic glutamate receptors present on taste cells and that underlie this postulated efferent transmission. We also studied what effect glutamate exerts on taste bud function. We isolated mouse taste buds and taste cells, conducted functional imaging using Fura 2, and used cellular biosensors to monitor taste-evoked transmitter release. The findings show that a large fraction of Presynaptic (Type III) taste bud cells (∼50%) respond to 100 µM glutamate, NMDA, or kainic acid (KA) with an increase in intracellular Ca(2+). In contrast, Receptor (Type II) taste cells rarely (4%) responded to 100 µM glutamate. At this concentration and with these compounds, these agonists activate glutamatergic synaptic receptors, not glutamate taste (umami) receptors. Moreover, applying glutamate, NMDA, or KA caused taste buds to secrete 5-HT, a Presynaptic taste cell transmitter, but not ATP, a Receptor cell transmitter. Indeed, glutamate-evoked 5-HT release inhibited taste-evoked ATP secretion. The findings are consistent with a role for glutamate in taste buds as an inhibitory efferent transmitter that acts via ionotropic synaptic glutamate receptors.

  20. Time response measurements of Rosemount Pressure Transmitters (model 3154) of Angra-1 power plant

    International Nuclear Information System (INIS)

    Santos, Roberto Carlos dos; Pereira, Iraci Martinez; Justino, Marcelo C.; Silva, Marcos C.

    2017-01-01

    This paper shows the Response of time five Rosemount model 3154N pressure transmitter from the Angra I Nuclear Power Plant. The tests were performed using the Hydraulic Ramp and Pressure Step Generator from the Sensor Response Time Measurement laboratory of CEN - Nuclear Engineering Center of IPEN. For each transmitter, damping was adjusted so that the time constant was less than or equal to 500 ms. This value has been determined so that the total value of the protection chain response time does not exceed the established maximum value of 2 seconds. For each transmitter ten tests were performed, obtaining mean values of time constant of 499.7 ms, 464.1 ms, 473.8 ms, 484.7 ms and 511.5 ms, with mean deviations 0.85%, 0.24%, 0.97%, 1.26% and 0.64% respectively. (author)

  1. Micro controller based design of digital transmitters for temperature measurements in reactors

    International Nuclear Information System (INIS)

    Nassar, M.A.M.

    2011-01-01

    Temperature transmitter is one of the most important transmitters in the nuclear reactor it is used for RTD (resistance temperature detector) signal conditioning. It has built-in current excitation, instrumentation amplifier, linearization and current output circuitry which amplifies the RTD signal and gives linearization to it. It is a part of a system to get temperature and monitoring it. This system is very cost and complicated. In this work a digital system is implemented by using micro controller techniques that replaces the existing system, one chip (PIC16f877) is used to build a digital system, which is more accurate and give more performance and low costs . RTD is the sensing element of temperature, its resistance increases with temperature. There are many types of transmitters in the reactor such as temperature, pressure, level and flow but temperature one is chosen because of temperature is one of the most important parameters in process control.

  2. Time response measurements of Rosemount Pressure Transmitters (model 3154) of Angra-1 power plant

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Roberto Carlos dos; Pereira, Iraci Martinez [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Justino, Marcelo C.; Silva, Marcos C., E-mail: rcsantos@ipen.br, E-mail: justino@eletronuclear.gov.br [Eletrobrás Termonuclear S.A. (ELETRONUCLEAR), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    This paper shows the Response of time five Rosemount model 3154N pressure transmitter from the Angra I Nuclear Power Plant. The tests were performed using the Hydraulic Ramp and Pressure Step Generator from the Sensor Response Time Measurement laboratory of CEN - Nuclear Engineering Center of IPEN. For each transmitter, damping was adjusted so that the time constant was less than or equal to 500 ms. This value has been determined so that the total value of the protection chain response time does not exceed the established maximum value of 2 seconds. For each transmitter ten tests were performed, obtaining mean values of time constant of 499.7 ms, 464.1 ms, 473.8 ms, 484.7 ms and 511.5 ms, with mean deviations 0.85%, 0.24%, 0.97%, 1.26% and 0.64% respectively. (author)

  3. Optimal position of the transmitter coil for wireless power transfer to the implantable device.

    Science.gov (United States)

    Jinghui Jian; Stanaćević, Milutin

    2014-01-01

    The maximum deliverable power through inductive link to the implantable device is limited by the tissue exposure to the electromagnetic field radiation. By moving away the transmitter coil from the body, the maximum deliverable power is increased as the magnitude of the electrical field at the interface with the body is kept constant. We demonstrate that the optimal distance between the transmitter coil and the body is on the order of 1 cm when the current of the transmitter coil is limited to 1 A. We also confirm that the conditions on the optimal frequency of the power transmission and the topology of the transmission coil remain the same as if the coil was directly adjacent to the body.

  4. High-energy, 2µm laser transmitter for coherent wind LIDAR

    Science.gov (United States)

    Singh, Upendra N.; Yu, Jirong; Kavaya, Michael J.; Koch, Grady J.

    2017-11-01

    A coherent Doppler lidar at 2μm wavelength has been built with higher output energy (300 mJ) than previously available. The laser transmitter is based on the solid-state Ho:Tm:LuLiF, a NASA Langley Research Center invented laser material for higher extraction efficiency. This diode pumped injection seeded MOPA has a transform limited line width and diffraction limited beam quality. NASA Langley Research Center is developing coherent wind lidar transmitter technology at eye-safe wavelength for satellite-based observation of wind on a global scale. The ability to profile wind is a key measurement for understanding and predicting atmospheric dynamics and is a critical measurement for improving weather forecasting and climate modeling. We would describe the development and performance of an engineering hardened 2μm laser transmitter for coherent Doppler wind measurement from ground/aircraft/space platform.

  5. Columnar transmitter based wireless power delivery system for implantable device in freely moving animals.

    Science.gov (United States)

    Eom, Kyungsik; Jeong, Joonsoo; Lee, Tae Hyung; Lee, Sung Eun; Jun, Sang Bum; Kim, Sung June

    2013-01-01

    A wireless power delivery system is developed to deliver electrical power to the neuroprosthetic devices that are implanted into animals freely moving inside the cage. The wireless powering cage is designed for long-term animal experiments without cumbersome wires for power supply or the replacement of batteries. In the present study, we propose a novel wireless power transmission system using resonator-based inductive links to increase power efficiency and to minimize the efficiency variations. A columnar transmitter coil is proposed to provide lateral uniformity of power efficiency. Using this columnar transmitter coil, only 7.2% efficiency fluctuation occurs from the maximum transmission efficiency of 25.9%. A flexible polymer-based planar type receiver coil is fabricated and assembled with a neural stimulator and an electrode. Using the designed columnar transmitter coil, the implantable device successfully operates while it moves freely inside the cage.

  6. Microscopically crumpled indium-tin-oxide thin films as compliant electrodes with tunable transmittance

    International Nuclear Information System (INIS)

    Ong, Hui-Yng; Shrestha, Milan; Lau, Gih-Keong

    2015-01-01

    Indium-tin-oxide (ITO) thin films are perceived to be stiff and brittle. This letter reports that crumpled ITO thin films on adhesive poly-acrylate dielectric elastomer can make compliant electrodes, sustaining compression of up to 25% × 25% equi-biaxial strain and unfolding. Its optical transmittance reduces with crumpling, but restored with unfolding. A dielectric elastomer actuator (DEA) using the 14.2% × 14.2% initially crumpled ITO thin-film electrodes is electrically activated to produce a 37% areal strain. Such electric unfolding turns the translucent DEA to be transparent, with transmittance increased from 39.14% to 52.08%. This transmittance tunability promises to make a low-cost smart privacy window

  7. Standard Test Methods for Solar Energy Transmittance and Reflectance (Terrestrial) of Sheet Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1971-01-01

    1.1 These test methods cover the measurement of solar energy transmittance and reflectance (terrestrial) of materials in sheet form. Method A, using a spectrophotometer, is applicable for both transmittance and reflectance and is the referee method. Method B is applicable only for measurement of transmittance using a pyranometer in an enclosure and the sun as the energy source. Specimens for Method A are limited in size by the geometry of the spectrophotometer while Method B requires a specimen 0.61 m2 (2 ft2). For the materials studied by the drafting task group, both test methods give essentially equivalent results. 1.2 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  8. Simulation and design of omni-directional high speed multibeam transmitter system

    Science.gov (United States)

    Tang, Jaw-Luen; Jui, Ping-Chang; Wang, Sun-Chen

    2006-09-01

    For future high speed indoor wireless communication, diffuse wireless optical communications offer more robust optical links against shadowing than line-of-sight links. However, their performance may be degraded by multipath dispersion resulting from surface reflections. We have developed a multipath diffusive propagation model capable of providing channel impulse responses data. It is aimed to design and simulate any multi-beam transmitter under a variety of indoor environments. In this paper, a multi-beam transmitter system with semi-sphere structure is proposed to combat the diverse effects of multipath distortion albeit, at the cost of increased laser power and cost. Simulation results of multiple impulse responses showed that this type of multi-beam transmitter can significantly improve the performance of BER suitable for high bit rate application. We present the performance and simulation results for both line-of-sight and diffuse link configurations.

  9. Standard Test Method for Solar Photometric Transmittance of Sheet Materials Using Sunlight

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1996-01-01

    1.1 This test method covers the measurement of solar photometric transmittance of materials in sheet form. Solar photometric transmittance is measured using a photometer (illuminance meter) in an enclosure with the sun and sky as the source of radiation. The enclosure and method of test is specified in Test Method E 1175 (or Test Method E 1084). 1.2 The purpose of this test method is to specify a photometric sensor to be used with the procedure for measuring the solar photometric transmittance of sheet materials containing inhomogeneities in their optical properties. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  10. Marine spawning sites of perch Perca fluviatilis revealed by oviduct-inserted acoustic transmitters

    DEFF Research Database (Denmark)

    Skovrind, Mikkel; Christensen, Emil A.F.; Carl, Henrik

    2013-01-01

    In the 1970s, a flood-protection system dramatically changed a large part of the coastal environment of Køge Bugt, a bay in the western Baltic Sea, from open coast to a brackish lagoon habitat. An anadromous stock of European perch Perca fluviatilis seems to have benefitted from this change...... a strong proof of concept of oviduct-inserted acoustic transmitters in brackish and marine fish spawning studies. The transmitter expulsions were validated using an egg map, which was based on visual observations of perch egg-strands, and 11 of the 12 expulsed transmitters (92%) were located in areas...... with eggs. Many fish spawned in the brackish water with salinities up to 9.6 PSU. These salinities are higher than those previously observed for European perch spawning in the wild, and call for further investigations of salinity tolerance in perch eggs...

  11. Transmitter and Translating Receiver Design For 64-ary Pulse Position Modulation (PPM)

    Energy Technology Data Exchange (ETDEWEB)

    Mendez, A J; Hernandez, V J; Gagliardi, R M; Bennett, C V

    2010-01-20

    This paper explores the architecture and design of an optically-implemented 64-ary PPM transmitter and direct-translating receiver that effectively translates incoming electrically-generated bit streams into optical PPM symbols (and vice-versa) at > 1 Gb/s data rates. The PPM transmitter is a cascade of optical switches operating at the frame rate. A corresponding receiver design is more difficult to architect and implement, since increasing data rates lead to correspondingly shorter decision times (slot times and frame times). We describe a solution in the form of a time-to-space mapping arrayed receiver that performs a translating algorithm represented as a code map. The technique for generating the code map is described, and the implementation of the receiver as a planar lightwave circuit is given. The techniques for implementing the transmitter and receiver can be generalized for any case of M-ary PPM.

  12. Microscopically crumpled indium-tin-oxide thin films as compliant electrodes with tunable transmittance

    Energy Technology Data Exchange (ETDEWEB)

    Ong, Hui-Yng [School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore 639798 (Singapore); School of Engineering, Nanyang Polytechnic, Singapore 569830 (Singapore); Shrestha, Milan; Lau, Gih-Keong, E-mail: mgklau@ntu.edu.sg [School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore 639798 (Singapore)

    2015-09-28

    Indium-tin-oxide (ITO) thin films are perceived to be stiff and brittle. This letter reports that crumpled ITO thin films on adhesive poly-acrylate dielectric elastomer can make compliant electrodes, sustaining compression of up to 25% × 25% equi-biaxial strain and unfolding. Its optical transmittance reduces with crumpling, but restored with unfolding. A dielectric elastomer actuator (DEA) using the 14.2% × 14.2% initially crumpled ITO thin-film electrodes is electrically activated to produce a 37% areal strain. Such electric unfolding turns the translucent DEA to be transparent, with transmittance increased from 39.14% to 52.08%. This transmittance tunability promises to make a low-cost smart privacy window.

  13. Methods of Phase and Power Control in Magnetron Transmitters for Superconducting Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Kazadevich, G. [MUONS Inc., Batavia; Johnson, R. [MUONS Inc., Batavia; Neubauer, M. [MUONS Inc., Batavia; Lebedev, V. [Fermilab; Schappert, W. [Fermilab; Yakovlev, V. [Fermilab

    2017-05-01

    Various methods of phase and power control in magnetron RF sources of superconducting accelerators intended for ADS-class projects were recently developed and studied with conventional 2.45 GHz, 1 kW, CW magnetrons operating in pulsed and CW regimes. Magnetron transmitters excited by a resonant (injection-locking) phasemodulated signal can provide phase and power control with the rates required for precise stabilization of phase and amplitude of the accelerating field in Superconducting RF (SRF) cavities of the intensity-frontier accelerators. An innovative technique that can significantly increase the magnetron transmitter efficiency at the widerange power control required for superconducting accelerators was developed and verified with the 2.45 GHz magnetrons operating in CW and pulsed regimes. High efficiency magnetron transmitters of this type can significantly reduce the capital and operation costs of the ADSclass accelerator projects.

  14. NOVEL TECHNIQUE OF POWER CONTROL IN MAGNETRON TRANSMITTERS FOR INTENSE ACCELERATORS

    Energy Technology Data Exchange (ETDEWEB)

    Kazakevich, G. [MUONS Inc., Batavia; Johnson, R. [MUONS Inc., Batavia; Neubauer, M.; Lebedev, V. [Fermilab; Schappert, W. [Fermilab; Yakovlev, V. [Fermilab

    2016-10-21

    A novel concept of a high-power magnetron transmitter allowing dynamic phase and power control at the frequency of locking signal is proposed. The transmitter compensating parasitic phase and amplitude modulations inherent in Superconducting RF (SRF) cavities within closed feedback loops is intended for powering of the intensity-frontier superconducting accelerators. The con- cept uses magnetrons driven by a sufficient resonant (in- jection-locking) signal and fed by the voltage which can be below the threshold of self-excitation. This provides an extended range of power control in a single magnetron at highest efficiency minimizing the cost of RF power unit and the operation cost. Proof-of-principle of the proposed concept demonstrated in pulsed and CW regimes with 2.45 GHz, 1kW magnetrons is discussed here. A conceptual scheme of the high-power transmitter allowing the dynamic wide-band phase and y power controls is presented and discussed.

  15. UV-vis light transmittance through tinted contact lenses and the effect of color on values.

    Science.gov (United States)

    Osuagwu, Uchechukwu L; Ogbuehi, Kelechi C

    2014-06-01

    To assess the transmittance, in the 200-700nm electromagnetic radiation spectrum, by popularly used tinted soft contact lenses (CLs). The spectra transmittances of ultraviolet (UV)-blocking (I Day Acuvue Define, Freshlook ONE DAY) and non-UV-blocking (Durasoft 3, Tutti, and NeoCosmo) tinted soft CLs were tested. The transmittance of each lens, including nine different colors of Freshlook CL was recorded on spectrophotometer, and the data used to also calculate a UV protection factor (PF) for each lens brand tested, with a higher value indicating a higher level of protection. The UV-blocking CLs significantly reduced UVC, UVB & UVA transmission and thereby meet the American National Standards Institution standard for class 2 UV blockers: a maximum of 30% transmittance of UVA and 5% transmittance of UVB wavelengths. In contrast, the Durasoft 3, Tutti, and NeoCosmo CLs demonstrated negligible UV-blockage. The Acuvue Define CL offered the greatest protection from UVC (PF=69) and UVB (PF=55), but with only 35% luminous transmittance, while the Freshlook CL (especially gemstone green) offered the best protection from UVA (PF=24) and showed about 55% translucency. Overall, the UV-blocking CLs performed equally well across the UV spectrum. Different colors of Freshlook CL transmitted statistically and clinically significantly different amounts of visible light but similar amounts of UVR. Freshlook and Acuvue Define CLs which are designated as UV-blockers significantly reduced UVR transmission to safe levels whereas Tutti, NeoCosmo and Durasoft 3 did not. Transmission within the Freshlook CL family was more dependent on color in the visible light spectrum, but not in the UV-spectrum, where the gemstone green performing best among the tested colors. Copyright © 2013 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  16. Research on control technology of hardware parallelism for marine controlled source electromagnetic transmitter

    Science.gov (United States)

    Wang, Meng; Deng, Ming; Luo, Xianhu; Zhao, Qingxian; Chen, Kai; Jing, Jianen

    2018-02-01

    The marine controlled source electromagnetic (CSEM) method has been recognized as an effective exploration method of shallow hydrocarbons around the world. We developed our own underwater marine CSEM transmitter that consisted of many functional modules with various response times. We previously adopted a centralized software-control technology to design the transmitter circuit topological structure. That structure probably generated a control disorder or malfunction. These undesirable conditions could lead to repeated recovery and deployment of the transmitter, which not only consumed time but also affected data continuity and establishment of stable and continuous CSEM field. We developed an instrument design concept named ‘control technology of hardware parallelism’. In this design, a noteworthy innovation of our new technology is to solve the above-mentioned problems at the physical and fundamental levels. We used several self-contained control-units to simultaneously accomplish the predetermined functions of the transmitter. The new solution relies on two technologies: multi-core embedded technology and multi-channel parallel optical-fiber data transmission technology. The first technology depends on many independent microcontrollers. Every microcontroller is only used to achieve a customized function. The second one relies on several multiple optical-fiber transmission channels realized by a complex programmable logic device and two optical-fiber conversion devices, which are used to establish a communication link between the shipboard monitoring and control-unit and underwater transmitter. We have conducted some marine experiments to verify the reliability and stability of the new method. In particular, the new technology used in the transmitter system could help us obtain more useful measured data in a limited time, improve real-time efficiency, and support the establishment of a stable CSEM field.

  17. Ultra-low power transmitter for encoding non-MR signals in Magnetic Resonance (MR) recordings

    DEFF Research Database (Denmark)

    Petersen, Jan Raagaard; Pedersen, Jan Ole; Zhurbenko, Vitaliy

    collection of data from non-MRI sensors. The transmitter consumes only 1.3mW while transmitting 2.7µW at 120MHz with high frequency stability. The presented design is useful in low power applications requiring high frequency stability and is intended for wireless transmission of non-MR signal recordings......Advancing Magnetic Resonance Imaging (MRI) technology requires integration of the MRI scanners with sensors and systems for monitoring various non-MRI signals. In this paper, we present design and integration of a low power AM radio transmitter into a 3T MRI scanner, which can be used for efficient...

  18. Investigating Feasibility Of Multiple UHF Passive RFID Transmitters Using Backscatter Modulation Scheme In BCI Applications

    DEFF Research Database (Denmark)

    Al Ajrawi, Shams; Sarkar, Mahasweta; Rao, Ramesh

    simulatedbrain matter to a receiver located on the surface of a simulatedskull. These analyses are essential for building a brain computerinterface application. We showcase theoretical and experimentalresults based on a phantom model of the human brain usingpassive RFID as the implantable transmitter operating...... in UHFrange. Furthermore, we use backscatter modulation as a powertransfer mechanism. Investigation on the feasibility and appli-cability of implantable UHF Passive RFID transmitters insidethe brain is done for capturing multi-channel ECoG signals at ahigh data transfer rate. Detailed analysis have been done...

  19. Evaluating in situ thermal transmittance of green buildings masonries—A case study

    Directory of Open Access Journals (Sweden)

    Francesco Asdrubali

    2014-01-01

    The paper presents the results of a measurement campaign of in situ thermal transmittance, performed in some buildings in the Umbria Region (Italy, designed implementing bio-architecture solutions. The analyzed walls were previously monitored with thermographic surveys in order to assess the correct application of the sensors. Results of the investigation show that in situ thermal transmittance measurements and theoretical calculated U-value are not in perfect agreement. The mismatch becomes important for monolithic structures such as walls made of thermal blocks without insulating layers.

  20. High transmittance optical films based on quantum dot doped nanoscale polymer dispersed liquid crystals

    Science.gov (United States)

    Gandhi, Sahil Sandesh; Chien, Liang-Chy

    2016-04-01

    We propose a simple way to fabricate highly transparent nanoscale polymer dispersed liquid crystal (nano-PDLC) films between glass substrates and investigate their incident angle dependent optical transmittance properties with both collimated and Lambertian intensity distribution light sources. We also demonstrate that doping nano-PDLC films with 0.1% InP/ZnS core/shell quantum dots (QD) results in a higher optical transmittance. This work lays the foundation for such nanostructured composites to potentially serve as roll-to-roll coatable light extraction or brightness enhancement films in emissive display applications, superior to complex nanocorrugation techniques proposed in the past.

  1. The miniature optical transmitter and transceiver for the High-Luminosity LHC (HL-LHC) experiments

    International Nuclear Information System (INIS)

    Liu, C; Zhao, X; Deng, B; Gong, D; Guo, D; Li, X; Liang, F; Liu, G; Liu, T; Xiang, A C; Ye, J; Chen, J; Huang, D; Hou, S; Teng, P-K

    2013-01-01

    We present the design and test results of the Miniature optical Transmitter (MTx) and Transceiver (MTRx) for the high luminosity LHC (HL-LHC) experiments. MTx and MTRx are Transmitter Optical Subassembly (TOSA) and Receiver Optical Subassembly (ROSA) based. There are two major developments: the Vertical Cavity Surface Emitting Laser (VCSEL) driver ASIC LOCld and the mechanical latch that provides the connection to fibers. In this paper, we concentrate on the justification of this work, the design of the latch and the test results of these two modules with a Commercial Off-The-Shelf (COTS) VCSEL driver

  2. Noise in relation to climate change. A first orientation; Geluid in relatie tot Klimaatverandering. Een eerste Verkenning

    Energy Technology Data Exchange (ETDEWEB)

    Kamp, I.

    2010-11-15

    klimaatverandering: toename van het aantal airco's in bedrijven en woningen, toename van energiebesparende ventilatiesystemen, en uitbreiding van het windturbinepark. Geluidaspecten van ventilatiesystemen, airco's en windturbines hebben gemeen dat verschillende frequenties een rol kunnen spelen. Op basis van beschikbaar onderzoek is het echter nog moeilijk de gezondheidseffecten van verschillende geluidcomponenten te onderscheiden en vast te stellen wat de lange termijn gezondheidseffecten zijn van de vaak momentane effecten (Koeman en van Poll, 2008). Van belang is de bevinding dat de luchtkwaliteit in het binnenmilieu op gespannen voet staat met zowel energiebesparende maatregelen als geluidaspecten. Een te efficiente isolatie van woningen gaat ten koste van de ventilatie en het geluid van de verschillende systemen leidt tot gedragsaanpassingen, die de prestatie van het systeem reduceren. Dit gaat samen met gezondheidseffecten (Leidelmeijer et al, 2009). Dit nadelige effect van een slechte luchtkwaliteit door onjuist gebruik van balansventilatie wordt bevestigd in de, in dit briefrapport gerapporteerde, panelstudie. Hoofdpijn komt naar voren als de belangrijkste klacht. Op nationaal niveau is de omvang van dit effect beperkt, maar als er geen technische oplossingen gevonden worden voor de problemen, veroorzaakt door ventilatiesystemen en koelingsystemen, is een toename in de toekomst wel te verwachten, De oplossing moet vooral gezocht worden op het technische vlak: het in evenwicht brengen van efficientie, geluid en luchtkwaliteit. Overlast van windturbines vraagt veeleer om maatregelen op het communicatieve vlak; onderzoek heeft aangetoond dat de hinder hiervan vooral wordt veroorzaakt door visuele aspecten en het gevoel dat er inbreuk wordt gedaan op de privacy als de turbine te dicht bij de woning geplaatst heeft en niet uitsluitend door akoestische aspecten. Op basis van deze eerste verkenning wordt meer onderzoek aanbevolen naar het effect van verschillende typen

  3. Glycine: an alternative transmitter candidate of the pallidosubthalamic projection neurons in the rat

    International Nuclear Information System (INIS)

    Takada, M.; Hattori, T.

    1987-01-01

    Autoradiographic retrograde tracing techniques with radioactive transmitters were used to analyse the identity of a putative transmitter in the rat pallidosubthalamic (GP-STN) pathway. One to 2 hours after the stereotaxic injection of 3 H-glycine restricted to the STN, a large number of neuronal somata were radiolabeled in the GP. No comparable labeling was observed following the injection of 3 H-gamma-aminobutyric acid ( 3 H-GABA) into the same nucleus even with survival times as long as 6 hours. Specifically, no significant somatic labeling was detected either in the GP or in the caudoputamen (CPU). Only when 3 H-GABA was injected into the substantia nigra did CPU and GP neurons become labeled. On the contrary, STN neuronal somata were invariably labeled 6 hours after the intrapallidal injection of 3 H-GABA, whereas no perikaryal labeling was observed in the STN after 3 H-glycine injection into the GP. The perikaryal labeling was prevented in all cases by intraventricular administration of colchicine 1 day before the isotope injections. The observations suggest that 3 H-glycine was preferentially transported retrogradely through the GP-STN pathway, and 3 H-GABA through the STN-GP projection. In view of the recent controversy on the role of GABA as a putative transmitter of the GP-STN projection, we now propose glycine as an alternative transmitter candidate of these critically situated neurons in the basal ganglia

  4. 47 CFR 73.653 - Operation of TV aural and visual transmitters.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Operation of TV aural and visual transmitters. 73.653 Section 73.653 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES RADIO BROADCAST SERVICES Television Broadcast Stations § 73.653 Operation of TV aural and visual...

  5. Measurement of the total solar energy transmittance (g-value) for conventional glazings

    DEFF Research Database (Denmark)

    Duer, Karsten

    1998-01-01

    Three different glazings have been investigated in the Danish experimental setup METSET. (A device for calorimetric measurement of total solar energy transmittance - g-value).The purpose of the measurements is to increase the confidence in the calorimetric measurements. This is done by comparison...

  6. Enhanced quantal release of excitatory transmitter in anterior cingulate cortex of adult mice with chronic pain

    Directory of Open Access Journals (Sweden)

    Zhao Ming-Gao

    2009-01-01

    Full Text Available Abstract The anterior cingulate cortex (ACC is a forebrain structure that plays important roles in emotion, learning, memory and persistent pain. Our previous studies have demonstrated that the enhancement of excitatory synaptic transmission was induced by peripheral inflammation and nerve injury in ACC synapses. However, little information is available on their presynaptic mechanisms, since the source of the enhanced synaptic transmission could include the enhanced probability of neurotransmitter release at existing release sites and/or increases in the number of available vesicles. The present study aims to perform quantal analysis of excitatory synapses in the ACC with chronic pain to examine the source of these increases. The quantal analysis revealed that both probability of transmitter release and number of available vesicles were increased in a mouse model of peripheral inflammation, whereas only probability of transmitter release but not number of available vesicles was enhanced in a mouse model of neuropathic pain. In addition, we compared the miniature excitatory postsynaptic potentials (mEPSCs in ACC synapses with those in other pain-related brain areas such as the amygdala and spinal cord. Interestingly, the rate and amplitude of mEPSCs in ACC synapses were significantly lower than those in the amygdala and spinal cord. Our studies provide strong evidences that chronic inflammatory pain increases both probability of transmitter release and number of available vesicles, whereas neuropathic pain increases only probability of transmitter release in the ACC synapses.

  7. Spatial integration of local transmitter responses in motoneurones of the turtle spinal cord in vitro

    DEFF Research Database (Denmark)

    Skydsgaard, Morten Arnika; Hounsgaard, J

    1994-01-01

    1. Integration of responses to local activation of transmitter receptors in the dendrites of motoneurones was investigated in a slice preparation of the turtle spinal cord. Membrane-active substances were applied from up to three independent iontophoresis electrodes during intracellular recording...

  8. Optimization of DP-M-QAM Transmitter using Cooperative Coevolutionary Genetic Algorithm

    DEFF Research Database (Denmark)

    Medeiros Diniz, Júlio César; Da Ros, Francesco; Porto da Silva, Edson

    2018-01-01

    We present a method for joint optimization of transmitter in-phase, quadrature and inter-polarization time skew, amplitude mismatch, and bias voltages. The method is based on a cooperative coevolutionary genetic algorithm with fitness functions extracted from a directly detected reference QAM sig...

  9. Analog direct-modulation behavior of semiconductor laser transmitters using optical FM demodulation

    NARCIS (Netherlands)

    Yabre, G.S.

    1998-01-01

    In this paper, we report a theoretical investigation of the analog modulation performance of a semiconductor laser transmitter which employs the direct optical FM demodulation. This analysis is based on the rate equations in which Langevin noise functions are included. The optical FM response has

  10. A beaded collar for dual micro GPS/VHF transmitter attachment to nutria

    Science.gov (United States)

    Haramis, G.M.; White, T.S.

    2011-01-01

    We report on the development of an approximately 85-g beaded collar for dual micro GPS/VHF transmitter attachment to semi-aquatic nutria (Myocastor coypus). Prototype collars were tested on captive nutria and refined during field trials. Central to the design was novel use of the VHF transmitter antenna as a collar. A circular collar was formed by passing the 44-cm antenna cable through a pre-made hole in the transmitter, leaving an approximately 16-cm upright antenna. GPS units were mounted separately via a hole in the base of each unit. For good satellite contact, GPS units (28 g) were maintained at the nape of the neck by counterbalance of the heavier VHF transmitters (50 g) positioned under the neck. To reduce friction, we lined the collar with alternate-sized plastic and, later, more durable nylon beads. The final collar configuration was worn for approximately 1 month deployments with only minor neck abrasion; one collar was worn successfully for 5 months. Foot entanglement remained the greatest risk of injury from the collar. By fitting collars tightly, we reduced the incidence of foot entanglement to 2 of 33 deployments (6%). Successful GPS tracks were acquired on 29 of 33 deployments (88%).

  11. A novel Chirped Return-to-Zero Transmitter and Transmission Experiments

    DEFF Research Database (Denmark)

    Liu, Fenghai; Peucheret, Christophe; Xueyan, Zheng

    2000-01-01

    A new 10 Gb/s chirped return-to-zero transmitter using CW light modulated by only one external modulator is proposed. Transmission over 3600 km of standard single mode fibre is performed in a re-circulating loop set-up with 80 km amplifier span....

  12. Widely Linear Blind Adaptive Equalization for Transmitter IQ-Imbalance/Skew Compensation in Multicarrier Systems

    DEFF Research Database (Denmark)

    Porto da Silva, Edson; Zibar, Darko

    2016-01-01

    Simple analytical widely linear complex-valued models for IQ-imbalance and IQ-skew effects in multicarrier transmitters are presented. To compensate for such effects, a 4×4 MIMO widely linear adaptive equalizer is proposed and experimentally validated....

  13. Adaptive Transmitter Optimization in Multiuser Multiantenna Systems: Theoretical Limits, Effect of Delays, and Performance Enhancements

    Directory of Open Access Journals (Sweden)

    Samardzija Dragan

    2005-01-01

    Full Text Available The advances in programmable and reconfigurable radios have rendered feasible transmitter optimization schemes that can greatly improve the performance of multiple-antenna multiuser systems. Reconfigurable radio platforms are particularly suitable for implementation of transmitter optimization at the base station. We consider the downlink of a wireless system with multiple transmit antennas at the base station and a number of mobile terminals (i.e., users each with a single receive antenna. Under an average transmit power constraint, we consider the maximum achievable sum data rates in the case of (1 zero-forcing (ZF spatial prefilter, (2 modified zero-forcing (MZF spatial prefilter, and (3 triangularization spatial prefilter coupled with dirty-paper coding (DPC transmission scheme. We show that the triangularization with DPC approaches the closed-loop MIMO rates (upper bound for higher SNRs. Further, the MZF solution performs very well for lower SNRs, while for higher SNRs, the rates for the ZF solution converge to the MZF rates. An important impediment that degrades the performance of such transmitter optimization schemes is the delay in channel state information (CSI. We characterize the fundamental limits of performance in the presence of delayed CSI and then propose performance enhancements using a linear MMSE predictor of the CSI that can be used in conjunction with transmitter optimization in multiple-antenna multiuser systems.

  14. Low power wide spectrum optical transmitter using avalanche mode LEDs in SOI CMOS technology

    NARCIS (Netherlands)

    Agarwal, V.; Dutta, S; Annema, AJ; Hueting, RJE; Steeneken, P.G.; Nauta, B

    2017-01-01

    This paper presents a low power monolithically integrated optical transmitter with avalanche mode light emitting diodes in a 140 nm silicon-on-insulator CMOS technology. Avalanche mode LEDs in silicon exhibit wide-spectrum electroluminescence (400 nm < λ < 850 nm), which has a significant

  15. Determination of Aluminium Content in Aluminium Hydroxide Formulation by FT-NIR Transmittance Spectroscopy

    DEFF Research Database (Denmark)

    Lai, Xuxin; Zheng, Yiwu; Søndergaard, Ib

    2007-01-01

    A method for determining the aluminium content of an aluminium hydroxide suspension using near infrared (NIR) transmittance spectroscopy has been developed. Inductively coupled plasma-atomic emission spectroscopy (ICP-AES) was used as reference method. The factors influencing the NIR analysis...... aluminium content in aluminium hydroxide suspension. (c) 2007 Elsevier Ltd. All rights reserved....

  16. Sb-Based Double Heterojunction Bipolar Transistors (DHBTs) With Fmax 650GHz for 340GHz Transmitter

    Science.gov (United States)

    2008-12-01

    PROPER IDENTIFICATION . NOT TO BE USED FOR INTERIM PROGRESS REPORTS SEE PAGE 2 FOR INTERIM PROGRESS REPORT INSTRUCTIONS MEMORANDUM OF TRANSMITTAL...conduction band lineup . These advantages have led to rapid progress in increasing device bandwidths, allowing competitive RF performance with established

  17. Auxiliary VHF transmitter to aid recovery of solar Argos/GPS PTTs

    Science.gov (United States)

    Christopher P. Hansen; Mark A. Rumble; R. Scott Gamo; Joshua J. Millspaugh

    2014-01-01

    While conducting greater sage-grouse (Centrocercus urophasianus) research, we found that solar-powered global positioning systems platform transmitter terminals (GPS PTTs) can be lost if the solar panel does not receive adequate sunlight. Thus, we developed 5-g (mortality sensor included; Prototype A) and 9.8-g (no mortality sensor; Prototype B) auxiliary very high...

  18. Remote Determination of Cloud Temperature and Transmittance from Spectral Radiance Measurements: Method and Results

    Science.gov (United States)

    1996-10-01

    atmospherics temperatura and humidity profiles. Validation tests performed on experimental spectra demonstrate the occuracy of the method with typical...indicated as with the title.) Passive Remota Sensing Infrared Spectra Cloud Temperatura Cloud Transmittance FTIR Spectrometer Icing Hazard Detection (DCD03E.IFO - 95.02.22) UNCLASSIFIED SECURITY CLASSIFICATION OF FORM

  19. Transmittance enhancement of sapphires with antireflective subwavelength grating patterned UV polymer surface structures by soft lithography.

    Science.gov (United States)

    Lee, Soo Hyun; Leem, Jung Woo; Yu, Jae Su

    2013-12-02

    We report the total and diffuse transmission enhancement of sapphires with the ultraviolet curable SU8 polymer surface structures consisting of conical subwavelength gratings (SWGs) at one- and both-side surfaces for different periods. The SWGs patterns on the silicon templates were transferred into the SU8 polymer film surface on sapphires by a simple and cost-effective soft lithography technique. For the fabricated samples, the surface morphologies, wetting behaviors, and optical characteristics were investigated. For theoretical optical analysis, a rigorous coupled-wave analysis method was used. At a period of 350 nm, the sample with SWGs on SU8 film/sapphire exhibited a hydrophobic surface and higher total transmittance compared to the bare sapphire over a wide wavelength of 450-1000 nm. As the period of SWGs was increased, the low total transmittance region of < 85% was shifted towards the longer wavelengths and became broader while the diffuse transmittance was increased (i.e., larger haze ratio). For the samples with SWGs at both-side surfaces, the total and diffuse transmittance spectra were further enhanced compared to the samples with SWGs at one-side surface. The theoretical optical calculation results showed a similar trend to the experimentally measured data.

  20. Topology optimised photonic crystal waveguide intersections with high-transmittance and low crosstalk

    DEFF Research Database (Denmark)

    Ikeda, N; Sugimoto, Y; Watanabe, Y

    2006-01-01

    Numerical and experimental studies on the photonic crystal waveguide intersection based on the topology optimisation design method are reported and the effectiveness of this technique is shown by achieving high transmittance spectra with low crosstalk for the straightforward beam-propagation line...

  1. Design of an Omnidirectional Multibeam Transmitter for High-Speed Indoor Wireless Communications

    Directory of Open Access Journals (Sweden)

    Tang Jaw-Luen

    2010-01-01

    Full Text Available For future high speed indoor wireless communication, diffuse wireless optical communications offer more robust optical links against shadowing than line-of-sight links. However, their performance may be degraded by multipath dispersion arising from surface reflections. We have developed a multipath diffusive propagation model capable of providing channel impulse responses data. It is aimed to design and simulate any multibeam transmitter under a variety of indoor environments. In this paper, a multi-beam transmitter system associated with hemisphere structure is proposed to fight against the diverse effects of multipath distortion albeit, at the cost of increased laser power and cost. Simulation results of multiple impulse responses showed that this type of multi-beam transmitter can significantly improve the performance of BER suitable for high bit rate application. We present the performance and simulation results for both line-of-sight and diffuse link configurations. We propose a design of power radiation pattern for a transmitter in achieving uniform and full coverage of power distributions for diffuse indoor optical wireless systems.

  2. An Improved Current-Doubler Rectifier for the Marine Controlled Source Electromagnetic Transmitter

    Directory of Open Access Journals (Sweden)

    Hongxi Song

    2018-01-01

    Full Text Available High power marine controlled source electromagnetic transmitters have gained interest with applications in marine geological survey and mineral resources exploration. The direct current to direct current (DC-DC converter that is typically used in marine transmitters has some issues, as the insulated-gate bipolar transistor (IGBT tube cannot achieve zero-voltage switching (ZVS. In particular, lagging-leg switching cannot easily achieve ZVS. The conversion efficiency of the heat converter requires improvement. This paper proposes an improved current-doubler rectifier for the marine controlled source electromagnetic transmitter (ICDR-MCSET. Resonant inductance is increased and a blocking capacitor is added to the converter (DC-DC circuit, where the converter can achieve ZVS in a wide load range. This results in the effective decrease of the heating temperature and the improvement of transformation efficiency. Saber software simulation and a 20 KW electromagnetic transmitter are used to verify the results, which show that the method is feasible and effective.

  3. Validation of temperature-sensitive radio transmitters for measurement of body temperature in small animals

    NARCIS (Netherlands)

    Williams, Joseph B.; Tieleman, B. I.; Shobrak, Mohammed

    2009-01-01

    As part of a study on the core body temperature (T(b)) of desert birds, we purposed to use temperature-sensitive implantable radio transmitters. Because of the difficulty in recapturing these birds, we needed to know if these electronic devices held their calibration over the duration of normal

  4. Improvements in X-band transmitter phase stability through Klystron body temperature regulation

    Science.gov (United States)

    Perez, R. M.

    1992-01-01

    This article describes the techniques used and experimental results obtained in improving transmitter stability by control of the klystron body temperature. Related work in the measurement of klystron phase control parameters (pushing factors) is also discussed. The contribution of wave guide temperature excursions to uplink phase stability is presented. Suggestions are made as to the direction of future work in this area.

  5. Estimation of thermal transmittance based on temperature measurements with the application of perturbation numbers

    Science.gov (United States)

    Nowoświat, Artur; Skrzypczyk, Jerzy; Krause, Paweł; Steidl, Tomasz; Winkler-Skalna, Agnieszka

    2018-05-01

    Fast estimation of thermal transmittance based on temperature measurements is uncertain, and the obtained results can be burdened with a large error. Nevertheless, such attempts should be undertaken merely due to the fact that a precise measurement by means of heat flux measurements is not always possible in field conditions (resentment of the residents during the measurements carried out inside their living quarters), and the calculation methods do not allow for the nonlinearity of thermal insulation, heat bridges or other fragments of building envelope of diversified thermal conductivity. The present paper offers the estimation of thermal transmittance and internal surface resistance with the use of temperature measurements (in particular with the use of thermovision). The proposed method has been verified through tests carried out on a laboratory test stand built in the open space, subjected to the influence of real meteorological conditions. The present elaboration involves the estimation of thermal transmittance by means of temperature measurements. Basing on the mentioned estimation, the authors present correction coefficients which have impact on the estimation accuracy. Furthermore, in the final part of the paper, various types of disturbance were allowed for using perturbation numbers, and the introduced by the authors "credibility area of thermal transmittance estimation" was determined.

  6. A standard operating procedure for the surgical implantation of transmitters in juvenile salmonids

    Science.gov (United States)

    Liedtke, T.L.; Beeman, J.W.; Gee, L.P.

    2012-01-01

    Biotelemetry is a useful tool to monitor the movements of animals and is widely applied in fisheries research. Radio or acoustic technology can be used, depending on the study design and the environmental conditions in the study area. A broad definition of telemetry also includes the use of Passive Integrated Transponder (PIT) tags, either separately or with a radio or acoustic transmitter. To use telemetry, fish must be equipped with a transmitter. Although there are several attachment procedures available, surgical implantation of transmitters in the abdominal cavity is recognized as the best technique for long-term telemetry studies in general (Stasko and Pincock, 1977; Winter, 1996; Jepsen, 2003), and specifically for juvenile salmonids, Oncorhynchus spp. (Adams and others, 1998a, 1998b; Martinelli and others, 1998; Hall and others, 2009). Studies that use telemetry assume that the processes by which the animals are captured, handled, and tagged, as well as the act of carrying the transmitter, will have minimal effect on their behavior and performance. This assumption, commonly stated as a lack of transmitter effects, must be valid if telemetry studies are to describe accurately the movements and behavior of an entire population of interest, rather than the subset of that population that carries transmitters. This document describes a standard operating procedure (SOP) for surgical implantation of radio or acoustic transmitters in juvenile salmonids. The procedures were developed from a broad base of published information, laboratory experiments, and practical experience in tagging thousands of fish for numerous studies of juvenile salmon movements near Columbia River and Snake River hydroelectric dams. Staff from the Western Fisheries Research Center's Columbia River Research Laboratory (CRRL) frequently have used telemetry studies to evaluate new structures or operations at hydroelectric dams in the Columbia River Basin, and these evaluations typically

  7. Determination of the SNPP VIIRS SDSM Screen Relative Transmittance From Both Yaw Maneuver and Regular On-Orbit Data

    Science.gov (United States)

    Lei, Ning; Chen, Xuexia; Xiong, Xiaoxiong

    2015-01-01

    The Visible Infrared Imaging Radiometer Suiteaboard the Suomi National Polar-orbiting Partnership (SNPP) satellite performs radiometric calibration of its reflective solar bands primarily through observing a sunlit onboard solar diffuser (SD). The SD bidirectional reflectance distribution function(BRDF) degradation factor is determined by an onboard SD stability monitor (SDSM), which observes the Sun through a pinhole screen and the sunlit SD. The transmittance of the SDSM pinhole screen over a range of solar angles was determined prelaunch and used initially to determine the BRDF degradation factor.The degradation-factor-versus-time curves were found to have a number of very large unphysical undulations likely due to the inaccuracy in the prelaunch determined SDSM screen transmittance.To refine the SDSM screen transmittance, satellite yaw maneuvers were carried out. With the SDSM screen relative transmittance determined from the yaw maneuver data, the computed BRDFdegradation factor curves still have large unphysical ripples, indicating that the projected solar horizontal angular step size in the yaw maneuver data is too large to resolve the transmittance at a fine angular scale. We develop a methodology to use both the yaw maneuver and a small portion of regular on-orbit data to determine the SDSM screen relative transmittance at a fine angular scale. We determine that the error standard deviation of the calculated relative transmittance ranges from 0.00030 (672 nm) to 0.00092 (926 nm). With the newly determined SDSM screen relative transmittance, the computed BRDF degradation factor behaves much more smoothly over time.

  8. Optimal Analytical Solution for a Capacitive Wireless Power Transfer System with One Transmitter and Two Receivers

    Directory of Open Access Journals (Sweden)

    Ben Minnaert

    2017-09-01

    Full Text Available Wireless power transfer from one transmitter to multiple receivers through inductive coupling is slowly entering the market. However, for certain applications, capacitive wireless power transfer (CWPT using electric coupling might be preferable. In this work, we determine closed-form expressions for a CWPT system with one transmitter and two receivers. We determine the optimal solution for two design requirements: (i maximum power transfer, and (ii maximum system efficiency. We derive the optimal loads and provide the analytical expressions for the efficiency and power. We show that the optimal load conductances for the maximum power configuration are always larger than for the maximum efficiency configuration. Furthermore, it is demonstrated that if the receivers are coupled, this can be compensated for by introducing susceptances that have the same value for both configurations. Finally, we numerically verify our results. We illustrate the similarities to the inductive wireless power transfer (IWPT solution and find that the same, but dual, expressions apply.

  9. Study on moving target detection to passive radar based on FM broadcast transmitter

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Target detection by a noncooperative illuminator is a topic of general interest in the electronic warfare field.First of all,direct-path interference(DPI)suppression which is the technique of bottleneck of moving target detection by a noncooperative frequency modulation(FM) broadcast transmitter is analyzed in this article;Secondly,a space-time-frequency domain synthetic solution to this problem is introduced:Adaptive nulling array processing is considered in the space domain,DPI cancellation based on adaptive fractional delay interpolation(AFDI)technique is used in planned time domain,and long-time coherent integration is utilized in the frequency domain;Finally,an experimental system is planned by considering FM broadcast transmitter as a noncooperative illuminator,Simulation results by real collected data show that the proposed method has a better performance of moving target detection.

  10. Multi-Band Multi-Tone Tunable Millimeter-Wave Frequency Synthesizer For Satellite Beacon Transmitter

    Science.gov (United States)

    Simons, Rainee N.; Wintucky, Edwin G.

    2016-01-01

    This paper presents the design and test results of a multi-band multi-tone tunable millimeter-wave frequency synthesizer, based on a solid-state frequency comb generator. The intended application of the synthesizer is in a satellite beacon transmitter for radio wave propagation studies at K-band (18 to 26.5 GHz), Q-band (37 to 42 GHz), and E-band (71 to 76 GHz). In addition, the architecture for a compact beacon transmitter, which includes the multi-tone synthesizer, polarizer, horn antenna, and power/control electronics, has been investigated for a notional space-to-ground radio wave propagation experiment payload on a small satellite. The above studies would enable the design of robust high throughput multi-Gbps data rate future space-to-ground satellite communication links.

  11. Surface modification of polymethyl methacrylate intraocular lenses by plasma for improvement of antithrombogenicity and transmittance

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Lihua; Wu Di; Chen Yashao; Wang Xiaoli; Zhao Guowei; Wan Haiyan [Key Laboratory of Applied Surface and Colloid Chemistry (Shaanxi Normal University), Ministry of Education, School of Chemistry and Materials Science, Chang' an South Road 199, Xi' an 710062 (China); Huang Changzheng [Able Eye Device Co. Ltd, Zhengzhou 450008 (China)

    2009-05-15

    To improve antithrombogenicity and reduce ultraviolet transmittance, polymethyl methacrylate intraocular lenses (PMMA IOLs) were pretreated with Ar plasma and combined with heparin (Hp), with polyglycol (PEG) and with both Hp and PEG in a plasma atmosphere. The resulting modified PMMA IOLs denoted as PEG-PMMA, Hp-PMMA and Hp-PEG-PMMA were characterized by attenuated total reflectance Fourier transfer infrared spectroscopy (ATR-FTIR), X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM), ultraviolet-visible spectroscopy (UV-vis), contact angle (CA) and platelet adhesion experiments. The results indicated that Hp and PEG had been successfully immobilized onto the surfaces of PMMA IOLs. Antithrombogenicity was improved remarkably and ultraviolet transmittance was reduced as well.

  12. Investigating Feasibility of Multiple UHF Passive RFID Transmitters Using Backscatter Modulation Scheme in BCI Applications

    DEFF Research Database (Denmark)

    Al Ajrawi, Shams; Sarkar, Mahasweta; Mihovska, Albena

    Building a wireless body area network (WBAN) application including implantable transceivers placed inside the human brain to collect the data from the electrodes and transmit them wirelessly to a controller placed outside the brain on the scalp faced major challenges. The transmission...... using passive RFID as the implantable transmitters and letting them operate in the UHF range. Backscatter modulation has been used as a power transfer mechanism. Investigation on the feasibility and applicability of implantable UHF Passive RFID transmitters inside the brain is done for capturing multi......-channel ECoG signals when traversing through a phantom brain model as a transmission medium for the experiments at a high data transfer rate. Detailed analysis has been done on parameters such as Received Signal Strength Indication (RSSI), signal to noise ratio (SNR), Maximum number of electrodes, Path Loss...

  13. Dependence of transmittance and group index on the coupling strength between constituents of a metamaterial

    International Nuclear Information System (INIS)

    Thuy Vu, Tran Thanh; Lee, Young Pak; Nguyen, Thanh Tung; Rhee, Joo Yull; Vu, Dinh Lam

    2011-01-01

    Recent studies on the coupling effects between constituent elements of metamaterials have opened up a new gateway to many fascinating electromagnetic properties and functionalities that cannot be explained by the uncoupled point of view. In this work, we numerically investigated, in a THz regime, the coupling between a cut wire and a split-ring resonator, which gives rise to an interesting phenomenon—the so-called electromagnetically induced transparency-like effect. The trade-off between the maximum transmittance of the transmission window and the group index, which depends on the coupling strength between constituent elements, was systematically studied. Furthermore, by characterizing this trade-off by the transmittance-delay product (figure of merit), a criterion for slow-light applications was provided

  14. Standard Test Method for Solar Transmittance (Terrestrial) of Sheet Materials Using Sunlight

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1986-01-01

    1.1 This test method covers the measurement of solar transmittance (terrestrial) of materials in sheet form by using a pyranometer, an enclosure, and the sun as the energy source. 1.2 This test method also allows measurement of solar transmittance at angles other than normal incidence. 1.3 This test method is applicable to sheet materials that are transparent, translucent, textured, or patterned. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  15. CMOS 60-GHz and E-band power amplifiers and transmitters

    CERN Document Server

    Zhao, Dixian

    2015-01-01

    This book focuses on the development of design techniques and methodologies for 60-GHz and E-band power amplifiers and transmitters at device, circuit and layout levels. The authors show the recent development of millimeter-wave design techniques, especially of power amplifiers and transmitters, and presents novel design concepts, such as “power transistor layout” and “4-way parallel-series power combiner”, that can enhance the output power and efficiency of power amplifiers in a compact silicon area. Five state-of-the-art 60-GHz and E-band designs with measured results are demonstrated to prove the effectiveness of the design concepts and hands-on methodologies presented. This book serves as a valuable reference for circuit designers to develop millimeter-wave building blocks for future 5G applications.

  16. FDTD simulation of transmittance characteristics of one-dimensional conducting electrodes.

    Science.gov (United States)

    Lee, Kilbock; Song, Seok Ho; Ahn, Jinho

    2014-03-24

    We investigated transparent conducting electrodes consisting of periodic one-dimensional Ag or Al grids with widths from 25 nm to 5 μm via the finite-difference time-domain method. To retain high transmittance, two grid configurations with opening ratios of 90% and 95% were simulated. Polarization-dependent characteristics of the transmission spectra revealed that the overall transmittance of micron-scale grid electrodes may be estimated by the sum of light power passing through the uncovered area and the light power penetrating the covered metal layer. However, several dominant physical phenomena significantly affect the transmission spectra of the nanoscale grids: Rayleigh anomaly, transmission decay in TE polarized mode, and localized surface plasmon resonance. We conclude that, for applications of transparent electrodes, the critical feature sizes of conducting 1D grids should not be less than the wavelength scale in order to maintain uniform and predictable transmission spectra and low electrical resistivity.

  17. Component-Level Selection and Qualification for the Global Ecosystem Dynamics Investigation (GEDI) Laser Altimeter Transmitter

    Science.gov (United States)

    Frese, Erich A.; Chiragh, Furqan L.; Switzer, Robert; Vasilyev, Aleksey A.; Thomes, Joe; Coyle, D. Barry; Stysley, Paul R.

    2018-01-01

    Flight quality solid-state lasers require a unique and extensive set of testing and qualification processes, both at the system and component levels to insure the laser's promised performance. As important as the overall laser transmitter design is, the quality and performance of individual subassemblies, optics, and electro-optics dictate the final laser unit's quality. The Global Ecosystem Dynamics Investigation (GEDI) laser transmitters employ all the usual components typical for a diode-pumped, solid-state laser, yet must each go through their own individual process of specification, modeling, performance demonstration, inspection, and destructive testing. These qualification processes and results for the laser crystals, laser diode arrays, electro-optics, and optics, will be reviewed as well as the relevant critical issues encountered, prior to their installation in the GEDI flight laser units.

  18. Application of smart transmitter technology in nuclear engineering measurements with level detection algorithm

    International Nuclear Information System (INIS)

    Kang, Hyun Gook; Seong, Poong Hyun

    1994-01-01

    In this study a programmable smart transmitter is designed and applied to the nuclear engineering measurements. In order to apply the smart transmitter technology to nuclear engineering measurements, the water level detection function is developed and applied in this work. In the real time system, the application of level detection algorithm can make the operator of the nuclear power plant sense the water level more rapidly. Furthermore this work can simplify the data communication between the level-sensing thermocouples and the main signal processor because the level signal is determined at field. The water level detection function reduces the detection time to about 8.3 seconds by processing the signal which has the time constant 250 seconds and the heavy noise signal

  19. Performance improvement of 100 kW high frequency transmitter for CW operation

    International Nuclear Information System (INIS)

    Kwak, J. G.; Yoon, J. S.; Bae, Y. D.; Cho, C. G.; Wang, S. J.; Lee, K. D.

    2001-08-01

    For the plasma heating of KSTAR(Korea Superconducting Tokamak Advanced Research)by using ICH(Ion Cyclotron Heating), it is designed that the selective ion heating and current drive are performed by the transmitter with the rf power of 8 MW in the frequency range of 25-60 MHz. 100 kW HF transmitter was constructed for the high voltage/current test of ICH antenna and HF transmission components. The output power is about 100 kW around 30 MHz. Thomson 581 tetrode is used for the final amplifier whose cavity type is ground cathode. Overall gain is above 15 dB and the bandwidth is about 100 kHz

  20. A 3D approximate maximum likelihood solver for localization of fish implanted with acoustic transmitters

    Science.gov (United States)

    Li, Xinya; Deng, Z. Daniel; Sun, Yannan; Martinez, Jayson J.; Fu, Tao; McMichael, Geoffrey A.; Carlson, Thomas J.

    2014-11-01

    Better understanding of fish behavior is vital for recovery of many endangered species including salmon. The Juvenile Salmon Acoustic Telemetry System (JSATS) was developed to observe the out-migratory behavior of juvenile salmonids tagged by surgical implantation of acoustic micro-transmitters and to estimate the survival when passing through dams on the Snake and Columbia Rivers. A robust three-dimensional solver was needed to accurately and efficiently estimate the time sequence of locations of fish tagged with JSATS acoustic transmitters, to describe in sufficient detail the information needed to assess the function of dam-passage design alternatives. An approximate maximum likelihood solver was developed using measurements of time difference of arrival from all hydrophones in receiving arrays on which a transmission was detected. Field experiments demonstrated that the developed solver performed significantly better in tracking efficiency and accuracy than other solvers described in the literature.

  1. A method of reconstructing the spatial measurement network by mobile measurement transmitter for shipbuilding

    International Nuclear Information System (INIS)

    Guo, Siyang; Lin, Jiarui; Yang, Linghui; Ren, Yongjie; Guo, Yin

    2017-01-01

    The workshop Measurement Position System (wMPS) is a distributed measurement system which is suitable for the large-scale metrology. However, there are some inevitable measurement problems in the shipbuilding industry, such as the restriction by obstacles and limited measurement range. To deal with these factors, this paper presents a method of reconstructing the spatial measurement network by mobile transmitter. A high-precision coordinate control network with more than six target points is established. The mobile measuring transmitter can be added into the measurement network using this coordinate control network with the spatial resection method. This method reconstructs the measurement network and broadens the measurement scope efficiently. To verify this method, two comparison experiments are designed with the laser tracker as the reference. The results demonstrate that the accuracy of point-to-point length is better than 0.4mm and the accuracy of coordinate measurement is better than 0.6mm. (paper)

  2. Accurate Modeling of Ionospheric Electromagnetic Fields Generated by a Low Altitude VLF Transmitter

    Science.gov (United States)

    2009-03-31

    AFRL-RV-HA-TR-2009-1055 Accurate Modeling of Ionospheric Electromagnetic Fields Generated by a Low Altitude VLF Transmitter ...m (or even 500 m) at mid to high latitudes . At low latitudes , the FDTD model exhibits variations that make it difficult to determine a reliable...Scientific, Final 3. DATES COVERED (From - To) 02-08-2006 – 31-12-2008 4. TITLE AND SUBTITLE Accurate Modeling of Ionospheric Electromagnetic Fields

  3. Pyrolyzed Photoresist Electrodes for Integration in Microfluidic Chips for Transmitter Detection from Biological Cells

    DEFF Research Database (Denmark)

    Larsen, Simon Tylsgaard; Argyraki, Aikaterini; Amato, Letizia

    2013-01-01

    In this study, we show how pyrolyzed photoresist carbon electrodes can be used for amperometric detection of potassium-induced transmitter release from large groups of neuronal PC 12 cells. This opens the way for the use of carbon film electrodes in microfabricated devices for neurochemical drug ...... by the difference in photoresist viscosity. By adding a soft bake step to the fabrication procedure, the flatness of pyrolyzed AZ 5214 electrodes could be improved which would facilitate their integration in microfluidic chip devices....

  4. An Advanced Detecting Scheme against a Signal Distortion with a Smart Transmitter

    International Nuclear Information System (INIS)

    Son, Jun Young; Kim, Young Mi

    2013-01-01

    The analog signal distortion could be detected. Also the data integrity for information security could be provided. The assurance of the integrity in digital information as well as analog signals is necessary. The above proposed schemes can be utilized for detecting the modification of the digital information or analog signal distortion without any of authentication. These effects have merits of the defenses for analog signals and cyber security in terms of information integrity. There are many kinds of measuring nuclear I and C system. Thus, the applicable algorithms may be different according to the lightness or the level of the security in each measuring system. In the future, finding and applying the efficient algorithms in each measuring systems in the nuclear power plant should be studied. As the I and C system will be gradually digitalized, the requirements for basic security concepts should be considered and applied. As IT technology has been much developed, measuring nuclear I and C (Instrument and Control) systems also is going to be evolving. At this point, the smart transmitter has been developed and tried to be applied. Recently, constructed nuclear power plants in Korea have adopted the smart meters. In case of Shin-Kori unit 3, about 59 safety grade smart transmitters and about 180 non-safety grade smart transmitters are used for measuring various signals. In the field of measuring nuclear I and C (Instrument and Control) systems, the cyber security problems can happen more. Thus, providing defense methods against possible cyber attacks are essential. In particular, the defense schemes for providing data information integrity will be essential. In addition, it is necessary to detect the analog signal distortion between the host smart transmitters and the client cabinet. In this paper, applicable one of directions and methods against the above two problems are proposed

  5. New developments on ChemCam laser transmitter and potential applications for other planetology programs

    Science.gov (United States)

    Faure, Benoît; Durand, Eric; Maurice, Sylvestre; Bruneau, Didier; Montmessin, Franck

    2017-11-01

    ChemCam is a LIBS Instrument mounted on the MSL 2011 NASA mission. The laser transmitter of this Instrument has been developed by the French society Thales Optronique (former Thales Laser) with a strong technical support from CNES. The paper will first rapidly present the performance of this laser and will then describe the postChemCam developments realized on and around this laser for new planetology programs.

  6. High optical transmittance of aluminum ultrathin film with hexagonal nanohole arrays as transparent electrode

    KAUST Repository

    Du, Qing Guo; Yue, Weisheng; Wang, Zhihong; Lau, Wah Tung; Ren, Hengjiang; Li, Er-Ping

    2016-01-01

    We fabricate samples of aluminum ultrathin films with hexagonal nanohole arrays and characterize the transmission performance. High optical transmittance larger than 60% over a broad wavelength range from 430 nm to 750 nm is attained experimentally. The Fano-type resonance of the excited surface plasmon plaritons and the directly transmitted light attribute to both of the broadband transmission enhancement and the transmission suppression dips. © 2016 Optical Society of America.

  7. Design and Development of a Pressure Transmitter Using Modified Inductance Measuring Network and Bellow Sensor

    OpenAIRE

    Venkata Lakshmi Narayana K.; Bhujanga Rao A.

    2013-01-01

    In this paper, a pressure transmitter using a modified op-amp based network for inductance measurement using a bellow as sensor has been proposed to measure the pressure and to convert pressure changes in to an electrical current which can be transmitted to a remote indicator. The change in inductance due to change in pressure is measured by an improved modified operational amplifier based network. The proposed network permits offset inductance compensation of sensing coil and also minimizes ...

  8. Optimal power allocation of a single transmitter-multiple receivers channel in a cognitive sensor network

    KAUST Repository

    Ayala Solares, Jose Roberto

    2012-08-01

    The optimal transmit power of a wireless sensor network with one transmitter and multiple receivers in a cognitive radio environment while satisfying independent peak, independent average, sum of peak and sum of average transmission rate constraints is derived. A suboptimal scheme is proposed to overcome the frequency of outages for the independent peak transmission rate constraint. In all cases, numerical results are provided for Rayleigh fading channels. © 2012 IEEE.

  9. Small-scale Scheimpflug lidar for aerosol extinction coefficient and vertical atmospheric transmittance detection.

    Science.gov (United States)

    Sun, Guodong; Qin, Laian; Hou, Zaihong; Jing, Xu; He, Feng; Tan, Fengfu; Zhang, Silong

    2018-03-19

    In this paper, a new prototypical Scheimpflug lidar capable of detecting the aerosol extinction coefficient and vertical atmospheric transmittance at 1 km above the ground is described. The lidar system operates at 532 nm and can be used to detect aerosol extinction coefficients throughout an entire day. Then, the vertical atmospheric transmittance can be determined from the extinction coefficients with the equation of numerical integration in this area. CCD flat fielding of the image data is used to mitigate the effects of pixel sensitivity variation. An efficient method of two-dimensional wavelet transform according to a local threshold value has been proposed to reduce the Gaussian white noise in the lidar signal. Furthermore, a new iteration method of backscattering ratio based on genetic algorithm is presented to calculate the aerosol extinction coefficient and vertical atmospheric transmittance. Some simulations are performed to reduce the different levels of noise in the simulated signal in order to test the precision of the de-noising method and inversion algorithm. The simulation result shows that the root-mean-square errors of extinction coefficients are all less than 0.02 km -1 , and that the relative errors of the atmospheric transmittance between the model and inversion data are below 0.56% for all cases. The feasibility of the instrument and the inversion algorithm have also been verified by an optical experiment. The average relative errors of aerosol extinction coefficients between the Scheimpflug lidar and the conventional backscattering elastic lidar are 3.54% and 2.79% in the full overlap heights of two time points, respectively. This work opens up new possibilities of using a small-scale Scheimpflug lidar system for the remote sensing of atmospheric aerosols.

  10. Worldwide OMEGA and Very Low Frequency (VLF) Transmitter Outages, January to December 1980.

    Science.gov (United States)

    1981-05-01

    WORLDWIDE OMEGA AND VERY LOW FREQUENCY IVLF) TRANSMITTER OUTAGE--ETC, MAY 81 L RZONCA ,’,L.ASSI LED FAA-CT-81-26 FAA-RD- B1 -29 UL7 A-I’ l15FDRL AIO...computer for the time period GBR - Rugby , England (16.00 kHz) January to December 1980. (For the purposes of this report, any downtime NA - Cutler, Maine

  11. An Advanced Detecting Scheme against a Signal Distortion with a Smart Transmitter

    Energy Technology Data Exchange (ETDEWEB)

    Son, Jun Young; Kim, Young Mi [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2013-10-15

    The analog signal distortion could be detected. Also the data integrity for information security could be provided. The assurance of the integrity in digital information as well as analog signals is necessary. The above proposed schemes can be utilized for detecting the modification of the digital information or analog signal distortion without any of authentication. These effects have merits of the defenses for analog signals and cyber security in terms of information integrity. There are many kinds of measuring nuclear I and C system. Thus, the applicable algorithms may be different according to the lightness or the level of the security in each measuring system. In the future, finding and applying the efficient algorithms in each measuring systems in the nuclear power plant should be studied. As the I and C system will be gradually digitalized, the requirements for basic security concepts should be considered and applied. As IT technology has been much developed, measuring nuclear I and C (Instrument and Control) systems also is going to be evolving. At this point, the smart transmitter has been developed and tried to be applied. Recently, constructed nuclear power plants in Korea have adopted the smart meters. In case of Shin-Kori unit 3, about 59 safety grade smart transmitters and about 180 non-safety grade smart transmitters are used for measuring various signals. In the field of measuring nuclear I and C (Instrument and Control) systems, the cyber security problems can happen more. Thus, providing defense methods against possible cyber attacks are essential. In particular, the defense schemes for providing data information integrity will be essential. In addition, it is necessary to detect the analog signal distortion between the host smart transmitters and the client cabinet. In this paper, applicable one of directions and methods against the above two problems are proposed.

  12. High optical transmittance of aluminum ultrathin film with hexagonal nanohole arrays as transparent electrode

    KAUST Repository

    Du, Qing Guo

    2016-02-24

    We fabricate samples of aluminum ultrathin films with hexagonal nanohole arrays and characterize the transmission performance. High optical transmittance larger than 60% over a broad wavelength range from 430 nm to 750 nm is attained experimentally. The Fano-type resonance of the excited surface plasmon plaritons and the directly transmitted light attribute to both of the broadband transmission enhancement and the transmission suppression dips. © 2016 Optical Society of America.

  13. Polarization-, carrier-, and format-selectable optical flow generation based on a multi-flow transmitter using passive polymers

    DEFF Research Database (Denmark)

    Katopodis, V.; Spyropoulou, M.; Tsokos, C.

    2016-01-01

    and acting as the interface between any software defined switch and the physical layer transport equipment. The transmitter has been evaluated within a flexible network node comprising programmable flexible wavelength selective switches (WSSs). Two single-flow scenarios based on a dual-polarization m...... generation is feasible with appropriate distribution of the client data in the digital domain and encapsulation into OTN containers. Configuration of the electrical and optical transmitter resources is performed via a developed software defined optics (SDO) platform residing on top of the transmitter...

  14. Effects of harness transmitters on behavior and reproduction of wild mallards

    Science.gov (United States)

    Pietz, Pamela J.; Krapu, Gary L.; Greenwood, Raymond J.; Lokemoen, John T.

    1993-01-01

    Radio telemetry has been an important research tool in waterfowl studies for >20 years, yet little effort has been made to evaluate potential effects of transmitters on the birds that carry them. As part of a 4-year mallard (Anas platyrhynchos) study in the prairie pothole region of North Dakota and Minnesota, we compared radio-marked and unmarked female mallards in terms of percent time observed feeding, resting, and preening; nest initiation date; and clutch size and egg volume. Radio-marked females carried a 23-g back-mounted transmitter attached with a 2-loop harness (Dwyer 1972). On average, radio-marked females tended to feed less, rest and preen more, initiate nests later, and lay smaller clutches and eggs than unmarked females. Thus, behavioral and reproductive data from ducks marked with back-mounted harness-attached transmitters may be biased. We recommend that new designs of radio packages be field tested and caution that effects may be masked under extreme environmental conditions.

  15. Analysis of Intermodulation Distortion in OFDM Based Transmitter Using EER Technique

    Directory of Open Access Journals (Sweden)

    S. Matejka

    2016-06-01

    Full Text Available During the last two decades, new digital modulation systems have appeared in the audio broadcasting. Such broadcasting systems require new transmitters’ concepts to enable the transmission of digitally modulated signals. Moreover, the selected modulation schemes (e.g. orthogonal frequency division multiplexing require a high linearity power stage, which typically exhibits low efficiency due to high peak-toaverage power ratio of the modulated signal. One of the promising transmitter concepts is the Kahn envelope elimination and restoration technique, where the original Cartesian in-phase and quadrature baseband signals are transformed to the envelope and phase signals. The main advantage of this technique is an ability to employ suitable types of highly efficient amplitude modulation transmitters for envelope amplification, while the phase modulated carrier is produced by an additional phase modulator. The substantial drawback of envelope elimination and restoration is nonideal recombination of linearly distorted amplitude signal and phase modulated carrier at the output power stage. The aim of this paper is twofold. Firstly, to analyze the effect of the envelope and phase signals bandwidth limitation on the modulated signal in-channel distortion and out-ofchannel emission. Secondly, to present the performance results as a reference for transmitter designers to properly set the envelope and phase paths to reach required in-channel signal quality and suppress out-of-channel products.

  16. A study on suppressing transmittance fluctuations for air-gapped Glan-type polarizing prisms

    Science.gov (United States)

    Zhang, Chuanfa; Li, Dailin; Zhu, Huafeng; Li, Chuanzhi; Jiao, Zhiyong; Wang, Ning; Xu, Zhaopeng; Wang, Xiumin; Song, Lianke

    2018-05-01

    Light intensity transmittance is a key parameter for the design of polarizing prisms, while sometimes its experimental curves based on spatial incident angle presents periodical fluctuations. Here, we propose a novel method for completely suppressing these fluctuations via setting a glued error angle in the air gap of Glan-Taylor prisms. The proposal consists of: an accurate formula of the intensity transmittance for Glan-Taylor prisms, a numerical simulation and a contrast experiment of Glan-Taylor prisms for analyzing the causes of the fluctuations, and a simple method for accurately measuring the glued error angle. The result indicates that when the setting glued error angle is larger than the critical angle for a certain polarizing prism, the fluctuations can be completely suppressed, and a smooth intensity transmittance curve can be obtained. Besides, the critical angle in the air gap for suppressing the fluctuations is decreased with the increase of beam spot size. This method has the advantage of having less demand for the prism position in optical systems.

  17. Configurable Transmitter and Systolic Channel Estimator Architectures for Data-Dependent Superimposed Training Communications Systems

    Directory of Open Access Journals (Sweden)

    E. Romero-Aguirre

    2012-01-01

    Full Text Available In this paper, a configurable superimposed training (ST/data-dependent ST (DDST transmitter and architecture based on array processors (APs for DDST channel estimation are presented. Both architectures, designed under full-hardware paradigm, were described using Verilog HDL, targeted in Xilinx Virtex-5 and they were compared with existent approaches. The synthesis results showed a FPGA slice consumption of 1% for the transmitter and 3% for the estimator with 160 and 115 MHz operating frequencies, respectively. The signal-to-quantization-noise ratio (SQNR performance of the transmitter is about 82 dB to support 4/16/64-QAM modulation. A Monte Carlo simulation demonstrates that the mean square error (MSE of the channel estimator implemented in hardware is practically the same as the one obtained with the floating-point golden model. The high performance and reduced hardware of the proposed architectures lead to the conclusion that the DDST concept can be applied in current communications standards.

  18. A dual-mode 6-9 GHz transmitter for OFDM-UWB

    International Nuclear Information System (INIS)

    Chen Yunfeng; Gao Ting; Li Wei; Li Ning; Ren Junyan

    2011-01-01

    This paper presents a fully integrated dual-mode 6 to 9 GHz transmitter for both WiMedia and China MB-OFDM UWB applications. The proposed transmitter consists of a dual-mode I/QLPF, an up-conversion mixer, a two-stage power driver amplifier and a broadband high-speed frequency divider with LO buffers for I/Q LO carrier generation. The measurement results show that the gain ripple of the transmitter is within ±1.5/±2.8 dB from 6 to 8.7/9 GHz. The output IP3 is about +13.2 dBm, the output 1dBCP is around +2.8 dBm, and the LO leakage/sideband rejection ratio is about -35/-38 dBc. The ESD protected chip is fabricated with a TSMC 0.13 μm RFCMOS process with a die size of 1.6 x 1.3 mm 2 and the core circuit consumes only 46 mA under a 1.2 V supply. (semiconductor integrated circuits)

  19. A dual-mode 6-9 GHz transmitter for OFDM-UWB

    Energy Technology Data Exchange (ETDEWEB)

    Chen Yunfeng; Gao Ting; Li Wei; Li Ning; Ren Junyan, E-mail: jyren@fudan.edu.cn, E-mail: w-li@fudan.edu.cn [State Key Laboratory of ASIC and System, Fudan University, Shanghai 201203 (China)

    2011-05-15

    This paper presents a fully integrated dual-mode 6 to 9 GHz transmitter for both WiMedia and China MB-OFDM UWB applications. The proposed transmitter consists of a dual-mode I/QLPF, an up-conversion mixer, a two-stage power driver amplifier and a broadband high-speed frequency divider with LO buffers for I/Q LO carrier generation. The measurement results show that the gain ripple of the transmitter is within {+-}1.5/{+-}2.8 dB from 6 to 8.7/9 GHz. The output IP3 is about +13.2 dBm, the output 1dBCP is around +2.8 dBm, and the LO leakage/sideband rejection ratio is about -35/-38 dBc. The ESD protected chip is fabricated with a TSMC 0.13 {mu}m RFCMOS process with a die size of 1.6 x 1.3 mm{sup 2} and the core circuit consumes only 46 mA under a 1.2 V supply. (semiconductor integrated circuits)

  20. A New Position Location System Using DTV Transmitter Identification Watermark Signals

    Directory of Open Access Journals (Sweden)

    Chouinard Jean-Yves

    2006-01-01

    Full Text Available A new position location technique using the transmitter identification (TxID RF watermark in the digital TV (DTV signals is proposed in this paper. Conventional global positioning system (GPS usually does not work well inside buildings due to the high frequency and weak field strength of the signal. In contrast to the GPS, the DTV signals are received from transmitters at relatively short distance, while the broadcast transmitters operate at levels up to the megawatts effective radiated power (ERP. Also the RF frequency of the DTV signal is much lower than the GPS, which makes it easier for the signal to penetrate buildings and other objects. The proposed position location system based on DTV TxID signal is presented in this paper. Practical receiver implementation issues including nonideal correlation and synchronization are analyzed and discussed. Performance of the proposed technique is evaluated through Monte Carlo simulations and compared with other existing position location systems. Possible ways to improve the accuracy of the new position location system is discussed.

  1. [Study on predicting firmness of watermelon by Vis/NIR diffuse transmittance technique].

    Science.gov (United States)

    Tian, Hai-Qing; Ying, Yi-Bin; Lu, Hui-Shan; Xu, Hui-Rong; Xie, Li-Juan; Fu, Xia-Ping; Yu, Hai-Yan

    2007-06-01

    Watermelon is a popular fruit in the world and firmness (FM) is one of the major characteristics used for assessing watermelon quality. The objective of the present research was to study the potential of visible/near Infrared (Vis/NIR) diffuse transmittance spectroscopy as a way for the nondestructive measurement of FM of watermelon. Statistical models between the spectra and FM were developed using partial least square (PLS) and principle component regression (PCR) methods. Performance of different models was assessed in terms of correlation coefficients (r) of validation set of samples and root mean square errors of prediction (RMSEP). Models for three kinds of mathematical treatments of spectra (original, first derivative and second derivative) were established. Savitsky-Goaly filter smoothing method was used for spectra data smoothing. The PLS model of the second derivative spectra gave the best prediction of FM, with a correlation coefficient (r) of 0. 974 and root mean square errors of prediction (RMSEP) of 0. 589 N using Savitsky-Goaly filter smoothing method. The results of this study indicate that NIR diffuse transmittance spectroscopy can be used to predict the FM of watermelon. The Vis/NIR diffuse transmittance technique will be valuable for the nandestructive detection large shape and thick peel fruits'.

  2. Degradation in PV Encapsulation Transmittance: An Interlaboratory Study Toward a Climate-Specific Test

    Energy Technology Data Exchange (ETDEWEB)

    Miller, David C.; Hacke, Peter L.; Kempe, Michael D.; Wohlgemuth, John H.; Annigoni, Eleonora; Sculati-Meillaud, Fanny; Ballion, Amal; Kohl, Michael; Bokria, Jayesh G.; Bruckman, Laura S.; French, Roger H.; Burns, David; Phillips, Nancy H.; Feng; Jiangtao; Elliott, Lamont; Scott, Kurt P.; Fowler, Sean; Gu, Xiaohong; Honeker, Christian C.; Khonkar, Hussam; Perret-Aebi, Laure-Emmanuelle; Shioda, Tsy

    2015-06-14

    Reduced optical transmittance of encapsulation resulting from ultraviolet (UV) degradation has frequently been identified as a cause of decreased PV module performance through the life of installations in the field. The present module safety and qualification standards, however, apply short UV doses only capable of examining design robustness or 'infant mortality' failures. Essential information that might be used to screen encapsulation through product lifetime remains unknown. For example, the relative efficacy of xenon-arc and UVA-340 fluorescent sources or the typical range of activation energy for degradation is not quantified. We have conducted an interlaboratory experiment to provide the understanding that will be used towards developing a climate- and configuration-specific (UV) weathering test. Five representative, known formulations of EVA were studied in addition to one TPU material. Replicate laminated silica/polymer/silica specimens are being examined at 14 institutions using a variety of indoor chambers (including Xe, UVA-340, and metal-halide light sources) or field aging. The solar-weighted transmittance, yellowness index, and the UV cut-off wavelength, determined from the measured hemispherical transmittance, are examined to provide understanding and guidance for the UV light source (lamp type) and temperature used in accelerated UV aging tests. Index Terms -- reliability, durability, thermal activation.

  3. Thermal Transmittance of Porous Hollow Clay Brick by Guarded Hot Box Method

    Science.gov (United States)

    Kim, Joonsoo

    2018-03-01

    The thermal property of a porous hollow clay brick was determined by measuring the thermal transmittance of the wall made of porous hollow clay bricks. Prior to the production of porous hollow clay bricks, nonporous and porous tiny clay bricks were prepared to determine the physico-mechanical properties by modifying the amount of wood flour and firing temperature. The bricks were produced by uniaxial pressing and then fired in an electric furnace. Their physico-mechanical properties were measured by water absorption, apparent porosity, bulk density, and compressive strength. The porous tiny clay bricks were produced with three types of wood flour: coarse wood flour (1-0.36 mm), medium-sized wood flour (0.36-0.15 mm), and fine wood flour (cement bricks. The two walls had a thermal transmittance of 1.42 and 2.72 W\\cdot m^{-2}\\cdot K^{-1}, respectively. The difference in thermal transmittance was due to the pores created with fine wood flour (< 0.08 mm) as a pore-forming agent.

  4. Thermal effects on the bulk luminous transmittance and track recording characteristics of dyed cellulose nitrate detectors

    International Nuclear Information System (INIS)

    Chakarvarti, S.K.; Lal, N.; Nagpaul, K.K.

    1980-01-01

    Simple heat treatment of polymers produces various typical morphological and chemical changes which consequently alter their physical and track registration properties. Bulk colour fading and alpha-track annealing effects have been studied in Kodak Pathe red-dyed cellulose nitrate film LR-115, type II and another Kodak product CA80-15, lightly rose-tinted cellulose nitrate, as a result of thermal annealing (room temperature to 155 0 C for times of 30 min to 16 h). The degree of colour fading has been measured in terms of percentage transmission of ordinary white light as sensed by a cadmium sulphide photoconductive cell, imitating the response of the human eye. It is found that at a given temperature, the transmittance rises first and acquires near-saturation after a certain annealing time. In the measurements reported here, it is seen that near-saturation transmittance is approximately proportional to the square root of the product of annealing time and temperature. The possibility of using these colour fading and transmittance measurements as an index of latent track fading is described. (orig.)

  5. Measurement of internal quality of watermelon by Vis/NIR diffuse transmittance technique

    Science.gov (United States)

    Tian, Haiqing; Xu, Huirong; Ying, Yibin; Lu, Huishan; Yu, Haiyan

    2006-10-01

    Watermelon is a popular fruit in the world. Soluble solids content (SSC) is major characteristic used for assessing watermelon internal quality. This study was about a method for nondestructive internal quality detection of watermelons by means of visible/Near Infrared (Vis/NIR) diffuse transmittance technique. Vis/NIR transmittance spectra of intact watermelons were acquired using a low-cost commercially available spectrometer when the watermelon was in motion (1.4m/s) and in static state. Spectra data were analyzed by partial least squares (PLS) method. The influences of different data preprocessing and spectra treatments were also investigated. Performance of different models was assessed in terms of root mean square errors of calibration (RMSEC), root mean square errors of prediction (RMSEP) and correlation coefficient (r) between the predicted and measured parameter values. Results showed that spectra data preprocessing influenced the performance of the calibration models and the PLS method can provide good results. The nondestructive Vis/NIR measurements provided good estimates of SSC index of watermelon both in motion and in static state, and the predicted values were highly correlated with destructively measured values. The results indicated the feasibility of Vis/NIR diffuse transmittance spectral analysis for predicting watermelon internal quality in a nondestructive way.

  6. Comparative Evaluation of Spectral Transmittance of Some Welding Glasses with ANSI Z87.1

    Directory of Open Access Journals (Sweden)

    saeed Rahmani

    2016-04-01

    Full Text Available Background: Welding emits harmful rays to the eyes. We evaluate and compare the UV, blue light and IR transmittance characteristics of some currently available welding safety protectors with ANSI Z87.1 criteria.Materials and Methods: Three type of welding safety protectors (three of each type have been evaluated for spectral transmittance. One-sample T-test was performed to establish is there a statistically significant difference between the standard criteria and UV, blue and IR regions for the welding protectors (α=0.05.Results: In ultraviolet (UV (far and near region, two types of the tested protectors (P1, P2 transmitted lower than the maximum allowable value specified in the standard (P<0.001. In infrared (IR spectrum only one type (P3 transmitted lower than the maximum allowable value specified in the standard (P<0.001. In blue light region, all of the tested protectors transmitted lower than the maximum allowable value specified in the standard (P<0.001.Conclusion: Although all of the tested glasses could meet some parts of the criteria, but none of them could meet the complete spectral transmittance requirements of ANSI Z87.1.

  7. The effects of PbZn1/3Nb2/3O3-doping on structural, thermal, optical, dielectric, and ferroelectric properties of BaTiO3 ceramics

    Science.gov (United States)

    Suchanicz, J.; Świerczek, K.; Sitko, D.; Czaja, P.; Marchet, P.; Czternastek, H.; Majda, D.

    2017-09-01

    Low-lead (1-x)BT-xPZN (x = 0, 0.025, 0.05, 0.075, 0.10, 0.125, and 0.15) ceramics were successfully synthesized by the spark-plasma-sintering method for the first time. Their phase transition behavior as well as structural, thermal, optical, and electrical properties was investigated. These materials exhibit the structure of perovskite-type solid solutions and undergo a sequence of phase transitions, typical of pure BaTiO3 (BT). The dielectric test results revealed that with the increase in the PbZn1/3Nb2/3O3 (PZN) content, the frequency dispersion of electric permittivity increases, whilst the dielectric/ferroelectric properties tend to deteriorate, which is characteristic of relaxor-type behavior. Therefore, it is reasonable to suppose that these ceramics progressively lack long-range ordering. These effects are due to the competition between lone-pair electrons' induced changes in the A-O band upon Pb2+ addition and ionic size differences. In general, the transition temperatures observed by dielectric analyses are in good agreement with those obtained from X-ray diffraction and differential scanning calorimetry measurements. The BT-PZN system may help to understand why relaxor behavior appears in perovskite-based materials. It appears that these materials can become a good starting point for the development of new low-lead electronic ceramics.

  8. Influence of P2O5 and Al2O3 content on the structure of erbium-doped borosilicate glasses and on their physical, thermal, optical and luminescence properties

    International Nuclear Information System (INIS)

    Bourhis, Kevin; Massera, Jonathan; Petit, Laeticia; Ihalainen, Heikki; Fargues, Alexandre; Cardinal, Thierry; Hupa, Leena; Hupa, Mikko; Dussauze, Marc; Rodriguez, Vincent; Boussard-Plédel, Catherine; Bureau, Bruno; Roiland, Claire; Ferraris, Monica

    2015-01-01

    Highlights: • Reorganization of the glass structure induced by the addition of P 2 O 5 or Al 2 O 3 . • Emission properties related to the presence of P or Al in the Er 3+ coordination shell. • Declustering observed upon addition of P 2 O 5 . • No declustering upon addition of Al 2 O 3 . - Abstract: The effect of P 2 O 5 and/or Al 2 O 3 addition in Er-doped borosilicate glasses on the physical, thermal, optical, and luminescence properties is investigated. The changes in these glass properties are related to the glass structure modifications induced by the addition of P 2 O 5 and/or Al 2 O 3 , which were probed by FTIR, 11 B MAS NMR and X-ray photoelectron spectroscopies. Variations of the polymerization degree of the silicate tetrahedra and modifications in the [3] B/ [4] B ratio are explained by a charge compensation mechanism due to the formation of AlO 4 , PO 4 groups and the formation of Al-O-P linkages in the glass network. From the absorption and luminescence properties of the Er 3+ ions at 980 nm and 1530 nm, declustering is suspected for the highest P 2 O 5 concentrations while for the highest Al 2 O 3 concentrations no declustering is observed

  9. Attaching transmitters to waterbirds using one versus two subcutaneous anchors: Retention and survival trade-offs

    Science.gov (United States)

    Lewis, Tyler; Esler, Daniel N.; Uher-Koch, Brian D.; Dickson, Rian D.; Anderson, Eric M.; Evenson, Joseph R.; Hupp, Jerry; Flint, Paul L.

    2017-01-01

    A major challenge of wildlife telemetry is choosing an attachment technique that maximizes transmitter retention while minimizing negative side effects. For waterbirds, attachment of transmitters with subcutaneous anchors has been an effective and well-established technique, having been used on >40 species. This method was recently modified to include a second subcutaneous anchor, presumably increasing transmitter retention beyond that of single-anchor attachments. This putative benefit may be offset, however, by increased health risks related to additional incisions and subcutaneous protrusions. To test this potential trade-off, we attached radiotransmitters to molting and wintering surf (Melanitta perspicillata) and white-winged scoters (M. fusca) during 2008 and 2009 in Washington State and southeast Alaska, USA, using single- (121 scoters) and double-anchor (128 scoters) attachment techniques. We estimated daily probabilities of survival and radio retention for each group, this being apparent retention for wintering scoters because we could not differentiate shed transmitters from flighted emigration. For scoters during the flightless remigial molt, we found that addition of a second anchor increased cumulative retention probability (±SE) over a 49-day period from 0.69 ± 0.11 for single-anchor to 0.88 ± 0.07 for double-anchor attachments, while having no effect on survival. However, during winter, scoters with double-anchor attachments experienced no improvement in apparent retention, while having significantly lower survival during their first 14 days following transmitter attachment; of 15 mortalities during this period, 11 had 2 subcutaneous anchors. From day 15 onward, winter survival rates were nearly identical for single- versus double-anchor attachments, indicating that adverse effects of subcutaneous anchors were mainly limited to the 14-day postattachment period. Overall, given that the survival cost of adding a second subcutaneous anchor

  10. Evaluation of three telemetry transmitter attachment methods for female silver-phase American eels ( Anguilla rostrata Lesueur)

    DEFF Research Database (Denmark)

    Cottrill, R.A.; Økland, F.; Aarestrup, Kim

    2006-01-01

    Declines in juvenile American eel (Anguilla rostrata Lesueur) abundance have led to concern about the impacts of anthropogenic structures on eel migration patterns. Telemetry provides an insightful tool for examining the movements of eels around these structures. Although there have been a number...... of studies investigating movements of Anguillid eels, using a variety of transmitter attachment techniques, there are few published evaluations of the effects of various tag attachment procedures. Hence, the effects of three telemetry attachment procedures were evaluated for female silver phase American eels...... of silver-phase American eels is not affected by the presence of telemetry transmitters or the method of transmitter attachment, even though swim performance decreases. However, transmitter retention rates varied considerably after the 12-week experimental period. Three gastric tags were regurgitated...

  11. Transmitter Spatial Diversity for FSO Uplink in Presence of Atmospheric Turbulence and Weather Conditions for Different IM Schemes

    Science.gov (United States)

    Viswanath, Anjitha; Kumar Jain, Virander; Kar, Subrat

    2017-12-01

    We investigate the error performance of an earth-to-satellite free space optical uplink using transmitter spatial diversity in presence of turbulence and weather conditions, using gamma-gamma distribution and Beer-Lambert law, respectively, for on-off keying (OOK), M-ary pulse position modulation (M-PPM) and M-ary differential PPM (M-DPPM) schemes. Weather conditions such as moderate, light and thin fog cause additional degradation, while dense or thick fog and clouds may lead to link failure. The bit error rate reduces with increase in the number of transmitters for all the schemes. However, beyond a certain number of transmitters, the reduction becomes marginal. Diversity gain remains almost constant for various weather conditions but increases with increase in ground-level turbulence or zenith angle. Further, the number of transmitters required to improve the performance to a desired level is less for M-PPM scheme than M-DPPM and OOK schemes.

  12. Calculations of the Total Number of Electrons Along a Ray Path Extending from the Transmitter to the Receiver

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Ionospheric Total Electron Content (TEC) is the total number of electrons in a column of unit cross section extending from the transmitter to the receiver. TEC is...

  13. Review of technical issues related to the failure of Rosemount pressure transmitters due to fill oil loss. Final report

    International Nuclear Information System (INIS)

    James, R.W.; Gaertner, J.P.; Burns, E.T.; Horn, A.; Lee, L.K.

    1994-08-01

    Rosemount pressure transmitters are extensively used in both safety and non-safety applications in US nuclear power plants. They are used to measure pressure, flow, and water level. Rosemount pressure transmitter models 1151, 1152, 1153A, 1153, and 1154 use a fill oil to hydraulically transmit process pressure exerted on outer isolating diaphragms to internal diaphragms. The resulting deflection of the internal diaphragms changes the distance between them and a central diaphragm separating the transmitter interior into two volumes. The change in distance is measured as a change in electrical capacitance between the isolating diaphragms and the central diaphragm and can be related to differential pressure. The fill oil also functions as a dielectric. It has been well established that this fill oil can potentially leak over time, decreasing transmitter accuracy and increasing transmitter response time. Ultimately, the transmitter can fail. An extensive effort has been expended by the nuclear power industry collectively to analyze this issue and develop technically sound and reasonable requirements to mitigate the effects of oil loss in Rosemount pressure transmitters. Despite this, technical concerns have still been raised regarding the technical validity of the past analyses of this problem and its scope. In May 1993, the NRC created an internal group to comprehensively review the Rosemount issue and the NRC's action in addressing it to ensure that all available technical information has been considered. Because this issue remains of active technical interest and because the past work on this subject has been done by many different groups and organizations, EPRI has prepared this report to thoroughly document the current technical understanding of this issue, to perform additional analysis, and to identify any appropriate additional technical research activities regarding oil loss in Rosemount pressure transmitters

  14. Single-Chip Fully Integrated Direct-Modulation CMOS RF Transmitters for Short-Range Wireless Applications

    Directory of Open Access Journals (Sweden)

    M. Jamal Deen

    2013-08-01

    Full Text Available Ultra-low power radio frequency (RF transceivers used in short-range application such as wireless sensor networks (WSNs require efficient, reliable and fully integrated transmitter architectures with minimal building blocks. This paper presents the design, implementation and performance evaluation of single-chip, fully integrated 2.4 GHz and 433 MHz RF transmitters using direct-modulation power voltage-controlled oscillators (PVCOs in addition to a 2.0 GHz phase-locked loop (PLL based transmitter. All three RF transmitters have been fabricated in a standard mixed-signal CMOS 0.18 µm technology. Measurement results of the 2.4 GHz transmitter show an improvement in drain efficiency from 27% to 36%. The 2.4 GHz and 433 MHz transmitters deliver an output power of 8 dBm with a phase noise of −122 dBc/Hz at 1 MHz offset, while drawing 15.4 mA of current and an output power of 6.5 dBm with a phase noise of −120 dBc/Hz at 1 MHz offset, while drawing 20.8 mA of current from 1.5 V power supplies, respectively. The PLL transmitter delivers an output power of 9 mW with a locking range of 128 MHz and consumes 26 mA from 1.8 V power supply. The experimental results demonstrate that the RF transmitters can be efficiently used in low power WSN applications.

  15. Effects of antenna placement and antibiotic treatment on loss of simulated transmitters and mortality in hybrid striped bass

    Science.gov (United States)

    Isely, J.J.; Young, S.P.; Jones, T.A.; Schaffler, James J.

    2002-01-01

    We compared the effects of two antenna placements (trailing and nontrailing) and antibiotic treatments (treated and nontreated) on mortality and transmitter loss in hybrid striped bass Morone saxatilis ?? M. chrysops (364 ?? 28 mm total length, 645 ?? 129 g [mean ?? SD]) implanted with simulated transmitters and held in the laboratory for 90 d. Although antibiotic treatment significantly increased the time to first mortality in fish surgically implanted with simulated transmitters (by an average of 14 d), we did not detect an effect on cumulative mortality. We also did not detect an effect of antenna type on the time to first mortality, but cumulative mortality was higher in the trailing antenna groups (50%) than in the nontrailing antenna groups (12%). Three transmitters were expelled during the study, all from trailing-antenna treatment groups, indicating a significant effect of antenna placement on the level of transmitter expulsion. Antibiotic treatment appears to be effective in preventing initial postsurgical infection; however, the antenna may serve as a continuous source of irritation and route of infection into the body cavity. The potential for infection and mortality in experimental animals must be weighed against the improved performance of transmitters with trailing antennas.

  16. Investigation on atmospheric transmittance based on spectral and total direct insolation data; Nissha data ni motozuku taiki tokaritsu no kento

    Energy Technology Data Exchange (ETDEWEB)

    Baba, H; Kanayama, K; Endo, N [Kitami Institute of Technology, Hokkaido (Japan)

    1997-11-25

    Spectral insolation values measured at Kitami since 1994 by using a multi-purpose spectral radiometer, and direct insolation data collected at seven locations are available. Based on these data, effects of sun`s altitude and atmospheric condition on atmospheric transmittance were discussed. Spectra of insolation received on the ground are subjected to scattering and absorption by gas and particulates, and show complex shapes while they transmit from the sun, reach the atmosphere of the earth and pass through the atmosphere. The Bird`s model is shown. Impact of the sun`s altitude on the spectra of insolation directly reaching the ground is small if the altitude is higher than 45 degrees. The impact grows suddenly large when it is lower than 30 degrees. Atmospheric turbidity (caused by aerosols generated by volcanic eruption or exhaust gases) affects the spectral transmittance over the whole wavelength region. Amount of steam in the atmosphere has a strong effect on the spectral transmittance in the steam absorption band. Total transmittance of the atmosphere was sought based on the measurement data of insolation directly reaching the ground at eight locations from Kitami to Shiono-misaki. The transmittance at each location is in a range from 0.75 to 0.83 showing close proximity. These data agreed well also with the average transmittance surveyed by the Meteorological Agency. 7 refs., 8 figs.

  17. Bandwidth scalable, coherent transmitter based on the parallel synthesis of multiple spectral slices using optical arbitrary waveform generation.

    Science.gov (United States)

    Geisler, David J; Fontaine, Nicolas K; Scott, Ryan P; He, Tingting; Paraschis, Loukas; Gerstel, Ori; Heritage, Jonathan P; Yoo, S J B

    2011-04-25

    We demonstrate an optical transmitter based on dynamic optical arbitrary waveform generation (OAWG) which is capable of creating high-bandwidth (THz) data waveforms in any modulation format using the parallel synthesis of multiple coherent spectral slices. As an initial demonstration, the transmitter uses only 5.5 GHz of electrical bandwidth and two 10-GHz-wide spectral slices to create 100-ns duration, 20-GHz optical waveforms in various modulation formats including differential phase-shift keying (DPSK), quaternary phase-shift keying (QPSK), and eight phase-shift keying (8PSK) with only changes in software. The experimentally generated waveforms showed clear eye openings and separated constellation points when measured using a real-time digital coherent receiver. Bit-error-rate (BER) performance analysis resulted in a BER < 9.8 × 10(-6) for DPSK and QPSK waveforms. Additionally, we experimentally demonstrate three-slice, 4-ns long waveforms that highlight the bandwidth scalable nature of the optical transmitter. The various generated waveforms show that the key transmitter properties (i.e., packet length, modulation format, data rate, and modulation filter shape) are software definable, and that the optical transmitter is capable of acting as a flexible bandwidth transmitter.

  18. Simultaneous identification of optical constants and PSD of spherical particles by multi-wavelength scattering-transmittance measurement

    Science.gov (United States)

    Zhang, Jun-You; Qi, Hong; Ren, Ya-Tao; Ruan, Li-Ming

    2018-04-01

    An accurate and stable identification technique is developed to retrieve the optical constants and particle size distributions (PSDs) of particle system simultaneously from the multi-wavelength scattering-transmittance signals by using the improved quantum particle swarm optimization algorithm. The Mie theory are selected to calculate the directional laser intensity scattered by particles and the spectral collimated transmittance. The sensitivity and objective function distribution analysis were conducted to evaluate the mathematical properties (i.e. ill-posedness and multimodality) of the inverse problems under three different optical signals combinations (i.e. the single-wavelength multi-angle light scattering signal, the single-wavelength multi-angle light scattering and spectral transmittance signal, and the multi-angle light scattering and spectral transmittance signal). It was found the best global convergence performance can be obtained by using the multi-wavelength scattering-transmittance signals. Meanwhile, the present technique have been tested under different Gaussian measurement noise to prove its feasibility in a large solution space. All the results show that the inverse technique by using multi-wavelength scattering-transmittance signals is effective and suitable for retrieving the optical complex refractive indices and PSD of particle system simultaneously.

  19. Onderwijzen in ondernemen : een studie betreffende de didactische voorwaarden en uitwerking van de beginselen van de structuurleer en het exemplarisch leren in relatie tot het middelbaar agrarisch onderwijs = Teaching farming : a study concerning the didactic conditions and elaboration of the principles of the structure theory and exemplary learning in relation to secondary agricultural education

    NARCIS (Netherlands)

    Lagemaat, van de D.

    1986-01-01

    Naar aanleiding van maatschappelijke veranderingen, die onder meer een aanpassing van het agrarisch onderwijs vragen, poogt de auteur via een filosofische benadering, gebaseerd op de beginselen van de reformatorische structuurleer van Dooyeweerd, en deels via eigen praktische ervaringen tot een

  20. Measurement of soluble solids content in watermelon by Vis/NIR diffuse transmittance technique.

    Science.gov (United States)

    Tian, Hai-qing; Ying, Yi-bin; Lu, Hui-shan; Fu, Xia-ping; Yu, Hai-yan

    2007-02-01

    Watermelon is a popular fruit in the world with soluble solids content (SSC) being one of the major characteristics used for assessing its quality. This study was aimed at obtaining a method for nondestructive SSC detection of watermelons by means of visible/near infrared (Vis/NIR) diffuse transmittance technique. Vis/NIR transmittance spectra of intact watermelons were acquired using a low-cost commercially available spectrometer operating over the range 350~1000 nm. Spectra data were analyzed by two multivariate calibration techniques: partial least squares (PLS) and principal component regression (PCR) methods. Two experiments were designed for two varieties of watermelons [Qilin (QL), Zaochunhongyu (ZC)], which have different skin thickness range and shape dimensions. The influences of different data preprocessing and spectra treatments were also investigated. Performance of different models was assessed in terms of root mean square errors of calibration (RMSEC), root mean square errors of prediction (RMSEP) and correlation coefficient (r) between the predicted and measured parameter values. Results showed that spectra data preprocessing influenced the performance of the calibration models. The first derivative spectra showed the best results with high correlation coefficient of determination [r=0.918 (QL); r=0.954 (ZC)], low RMSEP [0.65 degrees Brix (QL); 0.58 degrees Brix (ZC)], low RMSEC [0.48 degrees Brix (QL); 0.34 degrees Brix (ZC)] and small difference between the RMSEP and the RMSEC by PLS method. The nondestructive Vis/NIR measurements provided good estimates of SSC index of watermelon, and the predicted values were highly correlated with destructively measured values for SSC. The models based on smoothing spectra (Savitzky-Golay filter smoothing method) did not enhance the performance of calibration models obviously. The results indicated the feasibility of Vis/NIR diffuse transmittance spectral analysis for predicting watermelon SSC in a

  1. Evidence for a role of glutamate as an efferent transmitter in taste buds

    Directory of Open Access Journals (Sweden)

    Anderson Catherine B

    2010-06-01

    Full Text Available Abstract Background Glutamate has been proposed as a transmitter in the peripheral taste system in addition to its well-documented role as an umami taste stimulus. Evidence for a role as a transmitter includes the presence of ionotropic glutamate receptors in nerve fibers and taste cells, as well as the expression of the glutamate transporter GLAST in Type I taste cells. However, the source and targets of glutamate in lingual tissue are unclear. In the present study, we used molecular, physiological and immunohistochemical methods to investigate the origin of glutamate as well as the targeted receptors in taste buds. Results Using molecular and immunohistochemical techniques, we show that the vesicular transporters for glutamate, VGLUT 1 and 2, but not VGLUT3, are expressed in the nerve fibers surrounding taste buds but likely not in taste cells themselves. Further, we show that P2X2, a specific marker for gustatory but not trigeminal fibers, co-localizes with VGLUT2, suggesting the VGLUT-expressing nerve fibers are of gustatory origin. Calcium imaging indicates that GAD67-GFP Type III taste cells, but not T1R3-GFP Type II cells, respond to glutamate at concentrations expected for a glutamate transmitter, and further, that these responses are partially blocked by NBQX, a specific AMPA/Kainate receptor antagonist. RT-PCR and immunohistochemistry confirm the presence of the Kainate receptor GluR7 in Type III taste cells, suggesting it may be a target of glutamate released from gustatory nerve fibers. Conclusions Taken together, the results suggest that glutamate may be released from gustatory nerve fibers using a vesicular mechanism to modulate Type III taste cells via GluR7.

  2. Substance P as a putative efferent transmitter mediates GABAergic inhibition in mouse taste buds.

    Science.gov (United States)

    Huang, Anthony Y; Wu, Sandy Y

    2018-04-01

    Capsaicin-mediated modulation of taste nerve responses is thought to be produced indirectly by the actions of neuropeptides, for example, CGRP and substance P (SP), on taste cells implying they play a role in taste sensitivity. During the processing of gustatory information in taste buds, CGRP shapes peripheral taste signals via serotonergic signalling. The underlying assumption has been that SP exerts its effects on taste transmitter secretion in taste buds of mice. To test this assumption, we investigated the net effect of SP on taste-evoked ATP secretion from mouse taste buds, using functional calcium imaging with CHO cells expressing high-affinity transmitter receptors as cellular biosensors. Our results showed that SP elicited PLC activation-dependent intracellular Ca 2+ transients in taste cells via neurokinin 1 receptors, most likely on glutamate-aspartate transporter-expressing Type I cells. Furthermore, SP caused Type I cells to secrete GABA. Combined with the recent findings that GABA depresses taste-evoked ATP secretion, the current results indicate that SP elicited secretion of GABA, which provided negative feedback onto Type II (receptor) cells to reduce taste-evoked ATP secretion. These findings are consistent with a role for SP as an inhibitory transmitter that shapes the peripheral taste signals, via GABAergic signalling, during the processing of gustatory information in taste buds. Notably, the results suggest that SP is intimately associated with GABA in mammalian taste signal processing and demonstrate an unanticipated route for sensory information flow within the taste bud. © 2018 The British Pharmacological Society.

  3. Efficient Visible Light Communication Transmitters Based on Switching-Mode dc-dc Converters

    Science.gov (United States)

    2018-01-01

    Visible light communication (VLC) based on solid-state lighting (SSL) is a promising option either to supplement or to substitute existing radio frequency (RF) wireless communication in indoor environments. VLC systems take advantage of the fast modulation of the visible light that light emitting diodes (LEDs) enable. The switching-mode dc-to-dc converter (SMCdc-dc) must be the cornerstone of the LED driver of VLC transmitters in order to incorporate the communication functionality into LED lighting, keeping high power efficiency. However, the new requirements related to the communication, especially the high bandwidth that the LED driver must achieve, converts the design of the SMCdc-dc into a very challenging task. In this work, three different methods for achieving such a high bandwidth with an SMCdc-dc are presented: increasing the order of the SMCdc-dc output filter, increasing the number of voltage inputs, and increasing the number of phases. These three strategies are combinable and the optimum design depends on the particular VLC application, which determines the requirements of the VLC transmitter. As an example, an experimental VLC transmitter based on a two-phase buck converter with a fourth-order output filter will demonstrate that a bandwidth of several hundred kilohertz (kHz) can be achieved with output power levels close to 10 W and power efficiencies between 85% and 90%. In conclusion, the design strategy presented allows us to incorporate VLC into SSL, achieving high bit rates without damaging the power efficiency of LED lighting. PMID:29642455

  4. Influence of P{sub 2}O{sub 5} and Al{sub 2}O{sub 3} content on the structure of erbium-doped borosilicate glasses and on their physical, thermal, optical and luminescence properties

    Energy Technology Data Exchange (ETDEWEB)

    Bourhis, Kevin, E-mail: k.bourhis@argolight.com [Politecnico di Torino, DISAT, Istituto di Ingegneria e Fisica dei Materiali, Corso Duca degli Abruzzi 24, I-10129 Torino (Italy); Massera, Jonathan [Process Chemistry Centre, Åbo Akademi University, Biskopsgatan 8, FI-20500 Turku (Finland); Petit, Laeticia; Ihalainen, Heikki [nLIGHT Corporation, Sorronrinne 9, FI-08500 Lohja (Finland); Fargues, Alexandre; Cardinal, Thierry [CNRS, Université de Bordeaux, ISM, 351Cours de la Libération, F-33405 Talence (France); Hupa, Leena; Hupa, Mikko [Process Chemistry Centre, Åbo Akademi University, Biskopsgatan 8, FI-20500 Turku (Finland); Dussauze, Marc; Rodriguez, Vincent [CNRS, Université de Bordeaux, ICMCB, 87 Avenue du Dr Schweitzer, F-33608 Pessac (France); Boussard-Plédel, Catherine; Bureau, Bruno; Roiland, Claire [Equipe Verres et Céramiques, UMR-CNRS 6226, Inst. des Sciences chimiques de Rennes, Université de Rennes 1, 35042 Rennes CEDEX (France); Ferraris, Monica [Politecnico di Torino, DISAT, Istituto di Ingegneria e Fisica dei Materiali, Corso Duca degli Abruzzi 24, I-10129 Torino (Italy)

    2015-03-15

    Highlights: • Reorganization of the glass structure induced by the addition of P{sub 2}O{sub 5} or Al{sub 2}O{sub 3}. • Emission properties related to the presence of P or Al in the Er{sup 3+} coordination shell. • Declustering observed upon addition of P{sub 2}O{sub 5}. • No declustering upon addition of Al{sub 2}O{sub 3}. - Abstract: The effect of P{sub 2}O{sub 5} and/or Al{sub 2}O{sub 3} addition in Er-doped borosilicate glasses on the physical, thermal, optical, and luminescence properties is investigated. The changes in these glass properties are related to the glass structure modifications induced by the addition of P{sub 2}O{sub 5} and/or Al{sub 2}O{sub 3}, which were probed by FTIR, {sup 11}B MAS NMR and X-ray photoelectron spectroscopies. Variations of the polymerization degree of the silicate tetrahedra and modifications in the {sup [3]}B/{sup [4]}B ratio are explained by a charge compensation mechanism due to the formation of AlO{sub 4}, PO{sub 4} groups and the formation of Al-O-P linkages in the glass network. From the absorption and luminescence properties of the Er{sup 3+} ions at 980 nm and 1530 nm, declustering is suspected for the highest P{sub 2}O{sub 5} concentrations while for the highest Al{sub 2}O{sub 3} concentrations no declustering is observed.

  5. Optical Performance Measurements of the BELA EQM and FM Transmitter Laser during AIV

    Science.gov (United States)

    Althaus, C.; Michaelis, H.; Lingenauber, K.; Behnke, T.; Togno, S. d.; Kallenbach, R.; Wickhusen, K.; Althaus, C.

    2014-04-01

    The BepiColombo Laser Altimeter (BELA) onboard the Mercury Planetary Orbiter is Europe's first built Laser Altimeter for a planetary mission. Its main objectives are global mapping of Mercury's topography as well as measuring its tidal deformations to learn about the internal structure of this small terrestrial planet [1]. Crucial part of the instrument for this task is the transmitter laser. It must withstand all mission phases till operation in orbit and work within tight parameter margins. To ensure this a dedicated verification program has been performed at DLR Institute for Planetary Research Berlin which is described in the present paper.

  6. The infrared spectral transmittance of Aspergillus niger spore aggregated particle swarm

    Science.gov (United States)

    Zhao, Xinying; Hu, Yihua; Gu, Youlin; Li, Le

    2015-10-01

    Microorganism aggregated particle swarm, which is quite an important composition of complex media environment, can be developed as a new kind of infrared functional materials. Current researches mainly focus on the optical properties of single microorganism particle. As for the swarm, especially the microorganism aggregated particle swarm, a more accurate simulation model should be proposed to calculate its extinction effect. At the same time, certain parameters deserve to be discussed, which helps to better develop the microorganism aggregated particle swarm as a new kind of infrared functional materials. In this paper, take Aspergillus Niger spore as an example. On the one hand, a new calculation model is established. Firstly, the cluster-cluster aggregation (CCA) model is used to simulate the structure of Aspergillus Niger spore aggregated particle. Secondly, the single scattering extinction parameters for Aspergillus Niger spore aggregated particle are calculated by using the discrete dipole approximation (DDA) method. Thirdly, the transmittance of Aspergillus Niger spore aggregated particle swarm is simulated by using Monte Carlo method. On the other hand, based on the model proposed above, what influences can wavelength causes has been studied, including the spectral distribution of scattering intensity of Aspergillus Niger spore aggregated particle and the infrared spectral transmittance of the aggregated particle swarm within the range of 8-14μm incident infrared wavelengths. Numerical results indicate that the scattering intensity of Aspergillus Niger spore aggregated particle reduces with the increase of incident wavelengths at each scattering angle. Scattering energy mainly concentrates on the scattering angle between 0-40°, forward scattering has an obvious effect. In addition, the infrared transmittance of Aspergillus Niger spore aggregated particle swarm goes up with the increase of incident wavelengths. However, some turning points of the trend are

  7. Is lactate a volume transmitter of metabolic states of the brain?

    DEFF Research Database (Denmark)

    Bergersen, Linda H; Gjedde, Albert

    2012-01-01

    We present the perspective that lactate is a volume transmitter of cellular signals in brain that acutely and chronically regulate the energy metabolism of large neuronal ensembles. From this perspective, we interpret recent evidence to mean that lactate transmission serves the maintenance...... of network metabolism by two different mechanisms, one by regulating the formation of cAMP via the lactate receptor GPR81, the other by adjusting the NADH/NAD(+) redox ratios, both linked to the maintenance of brain energy turnover and possibly cerebral blood flow. The role of lactate as mediator...

  8. In-situ measurement of response time of RTDs and pressure transmitters in nuclear power plants

    International Nuclear Information System (INIS)

    Hashemian, H.M.; Riner, J.L.

    1993-01-01

    Response time measurements are performed once every fuel cycle on most safety-related temperature and pressure sensors in a majority of nuclear power plants in the US. This paper provides a review of the methods that are used for these measurements. The methods are referred to as the Loop Current Step Response (LCSR) test, which is used for response time testing of temperature sensors, and noise analysis and power interrupt (PI) tests, which are used for response time testing of pressure, level, and flow transmitters

  9. Overview of solid state lasers with applications as LIDAR transmitters and optical image amplifiers

    International Nuclear Information System (INIS)

    Powell, R.C.; Basiev, T.T.; Zverev, P.G.

    2000-01-01

    Full text: This talk will review the current status of solid state lasers. Then a specific class of solid state lasers, Raman lasers, will be discussed as a specific example of new technology development. The spectroscopic properties of the materials are used in these lasers is presented and the use of these materials in shared-, coupled-, and external-resonator laser systems is described. System design parameters affecting efficiency, beam quality, and temporal pulse width are discussed. Examples will be presented of the use of these lasers for transmitters in atmospheric and marine imaging light detection and ranging (LIDAR) systems and in optical amplifiers

  10. Abdominally implanted satellite transmitters affect reproduction and survival rather than migration of large shorebirds

    Science.gov (United States)

    Hooijmeijer, Jos C. E. W.; Gill, Robert E.; Mulcahy, Daniel M.; Tibbitts, T. Lee; Kentie, Rosemarie; Gerritsen, Gerrit J.; Bruinzeel, Leo W.; Tijssen, David C.; Harwood, Christopher M.; Piersma, Theunis

    2014-01-01

    Satellite telemetry has become a common technique to investigate avian life-histories, but whether such tagging will affect fitness is a critical unknown. In this study, we evaluate multi-year effects of implanted transmitters on migratory timing and reproductive performance in shorebirds. Shorebirds increasingly are recognized as good models in ecology and evolution. That many of them are of conservation concern adds to the research responsibilities. In May 2009, we captured 56 female Black-tailed Godwits Limosa limosa limosa during late incubation in The Netherlands. Of these, 15 birds were equipped with 26-g satellite transmitters with a percutaneous antenna (7.8 % ± 0.2 SD of body mass), surgically implanted in the coelom. We compared immediate nest survival, timing of migration, subsequent nest site fidelity and reproductive behaviour including egg laying with those of the remaining birds, a comparison group of 41 females. We found no effects on immediate nest survival. Fledging success and subsequent southward and northward migration patterns of the implanted birds conformed to the expectations, and arrival time on the breeding grounds in 2010–2012 did not differ from the comparison group. Compared with the comparison group, in the year after implantation, implanted birds were equally faithful to the nest site and showed equal territorial behaviour, but a paucity of behaviours indicating nests or clutches. In the 3 years after implantation, the yearly apparent survival of implanted birds was 16 % points lower. Despite intense searching, we found only three eggs of two implanted birds; all were deformed. A similarly deformed egg was reported in a similarly implanted Whimbrel Numenius phaeopus returning to breed in central Alaska. The presence in the body cavity of an object slightly smaller than a normal egg may thus lead to egg malformation and, likely, reduced egg viability. That the use of implanted satellite transmitters in these large shorebirds

  11. Energy-Efficient Power Allocation of Cognitive Radio Systems without CSI at the Transmitter

    KAUST Repository

    Sboui, Lokman

    2015-01-07

    Two major issues are facing today’s wireless communications evolution: -Spectrum scarcity: Need for more bandwidth. As a solution, the Cognitive Radio (CR) paradigm, where secondary users (unlicensed) share the spectrum with licensed users, was introduced. -Energy consumption and CO2 emission: The ICT produce 2% of global CO2 emission (equivalent to the aviation industry emission). The cellular networks produces 0.2%. As solution energy efficient systems should be designed rather than traditional spectral efficient systems. In this work, we aim to determine the optimal energy efficient power allocation of CR when the channel state information at the transmitter CSI-T is not available.

  12. Arc Security System Based on Harmonics Detection for the TS ICRH Transmitter

    International Nuclear Information System (INIS)

    Berger-by, G.; Beaumont, B.; Lombard, G.; Millon, L.; Mollard, P.; Volpe, D.

    2006-01-01

    Since 1999 and with the help of I.P.P. (Institut fuer Plasmaphysik) Garching, we have tested in the Tore Supra (T.S.) ICRH transmitter, arcs security systems based on harmonics detection in a frequency band lower than the generator frequency. These systems have been designed for ASDEX in order to discriminate between the arcs and the ELMS mismatches during H-mode plasmas; they have been supplied to T.S. by a loan contract by I.P.P. The first tests done in T.S. were very successful and have permitted in 2000 to build a prototype matching T.S. technical requirements. These systems have some advantages in comparison with traditional securities which are based on use of a level on the V r /V f (Reflected to Forward voltage ratio) calculation . They do not use calculation, calibration with frequency or level. They can use RF signals from directional couplers or probes, so they are fully independent of the measurement systems. The detection bandwidth (4 MHz-35 MHz on TS) is independent of the antennae working frequencies. The detection principle is therefore insensitive to the crosstalk between the antennae and to the antennae coupling variations. The RF arc security box is installed in the generator hall which can be located far from the torus hall and the antennae (about 50 m on T.S.) a feature which is very relevant for the ITER transmitters. In 2001 we have built 3 systems based on our prototype in order to improve the protection of the 3 ICRH generators and antennae. These systems use industrial pass-band filters and a very sensitive linear detection (- 60 dBm) in order to facilitate the adjustment. Optical fibbers are used to transfer, with a very high immunity, the trip information to the generator electronic pilot. To guarantee safe operation, a checking test of the entire security chain is performed with a 10 MHz RF oscillator before each plasma start. The RF principle used on T.S. ICRH transmitter and its electronic interactions with the VME command control of

  13. Energy-Efficient Power Allocation of Cognitive Radio Systems without CSI at the Transmitter

    KAUST Repository

    Sboui, Lokman; Rezki, Zouheir; Alouini, Mohamed-Slim

    2015-01-01

    Two major issues are facing today’s wireless communications evolution: -Spectrum scarcity: Need for more bandwidth. As a solution, the Cognitive Radio (CR) paradigm, where secondary users (unlicensed) share the spectrum with licensed users, was introduced. -Energy consumption and CO2 emission: The ICT produce 2% of global CO2 emission (equivalent to the aviation industry emission). The cellular networks produces 0.2%. As solution energy efficient systems should be designed rather than traditional spectral efficient systems. In this work, we aim to determine the optimal energy efficient power allocation of CR when the channel state information at the transmitter CSI-T is not available.

  14. Die genetiese verbetering van wyndruifkultivars en wyngisrasse vir ’n markgerigte wynbedryf: Nuwe benaderings tot die oeroue kuns van wynbereiding

    Directory of Open Access Journals (Sweden)

    I. S. Pretorius

    2003-09-01

    Full Text Available Die groeiende gaping tussen wynproduksie en wynverbruik, die verskuiwing van verbruikersvoorkeure vanaf basiese kommoditeitswyn na topgehaltewyn en die uitmergelende mededinging wat ekonomiese globalisering meebring, vereis ’n totale omwenteling in die magiese wonderwêreld van wyn. In die proses om die wynbedryf van ’n produksiegedrewe bedryf na ’n markgerigte onderneming te transformeer, word daar, onder andere, toenemend op biotegnologiese innovasie gereken om die wynbedryf met ’n kwantumsprong oor die formidabele markuitdagings van die 21ste eeu te lanseer. Markgerigte ontwerpersdruifkultivars en -wyngisrasse word tans met chirurgiese presisie geneties geprogrammeer vir die kostemededingende produksie van hoë gehalte druiwe en wyn met relatief minimale insette en ’n lae omgewingsimpak. Ten opsigte van wingerdbiotegnologie behels dit die daarstelling van strestolerante en siekteweer-standbiedende Vitis vinifera-variëteite met verhoogde produktiwiteit, doeltreffendheid, volhoubaarheid en omgewingsvriendelikheid, veral betreffende plaag- en siektebeheer, waterverbruiksdoeltreffendheid en druifgehalte. Met betrekking tot wyngisbiotegnologie val die klem op die ontwikkeling van Saccharomyces cerevisiae-rasse met verbeterde gistings-, prosesserings- en biopreserveringsvermoëns, en kapasiteite vir die verhoging van die heilsaamheid en sensoriese kwaliteit van wyn. Die suksesvolle kommersialisering van transgeniese druifkultivars en wyngiste hang van ’n menigte wetenskaplike, tegniese, veiligheids-, etiese, wetlike, ekonomiese  en bemarkingsfaktore af, en daarom sal dit dwaas wees om oor die kort termyn hoë verwagtings te koester. In die lig van die fenomenale potensiële voordele van pasgemaakte druifvariëteite en gisrasse, sal dit oor die lang termyn ewe selfvernietigend wees indien hierdie strategies belangrike “lewensversekeringspolis” nie deur die wynbedryf uitgeneem word nie. Hierdie oorsig lig die belangrikste voorbeelde

  15. Comparison of TVT, TVT-O/TOT and mini slings for the treatment of female stress urinary incontinence: 30 months follow up in 531 patients.

    Science.gov (United States)

    Stavros, Charalambous; Ioannis, Vouros; Vasileios, Sakalis I; Gkotsi, Anastasia Ch; Georgios, Salpiggidis; Papathanasiou, Athanasios; Rombis, Vasileios

    2012-09-01

    Although mid-urethral slings (MUS), have been extensively used for the treatment of female stress urinary incontinence (SUI), no published data exists for the efficiency and the complications of these methods in large patient series. This is a retrospective analysis on patients who underwent MUS surgery since 1999. 531 patients were studied and the results of preoperative assessment, perioperative, early postoperatively and each follow up were registered. Patients were classified in three groups according to the MUS used. Efficacy of each method was evaluated in terms of early postoperative course, late complications and patient's symptoms improvement based questioners, pad test, uroflowmetry, filling cystometry and ultrasonography. Evaluation took place at 7th and 30th postoperative day, 3rd and 12th month and then annually. Each patient was characterized as cured, improved or failed. Trans Obturator (TO) group prevailed in efficiency with no significant differences between trans obturator route with inside-out (TVT-O) and outside-in (TOT). Success rate at 30th month evaluation, was higher in the TO group than in Tension-free Vaginal Tape (TVT) or Single-Incision Mini Slings (SIMS) group (93.4% vs 89.5%, 93.4% vs. 91.7%). None TVT patient required reoperation for remaining/reoccurring SUI, while 1.04% of TO group and 5.48% of SIMS group did. Patients of TVT group underwent reoperation for tape related complications in 2.25%, while 2.07% of TO group and none of SIMS group did. The potential limitation of the study is its retrospective character. Even though TO tapes and SIMS seem more efficient than TVT, they carry a risk of SUI re-occurrence that must be weighted towards the risk of potential complications after TVT.

  16. ’n Prinsipiële diskoers oor die epistemologiese fundering van die Pastorale Teologie: ’n Oproep tot reformasie

    Directory of Open Access Journals (Sweden)

    Johan Janse van Rensburg

    2015-03-01

    Full Text Available Hierdie artikel is as ’n huldeblyk aan prof. George Lotter by sy aftrede geskryf en uit erkenning vir sy bydrae tot die wetenskapsbeoefening van die Praktiese Teologie. Die artikel ondersoek die huidige konteks van die pastorale teologie. Aangesien epistemologiese keuses die metodiek en uitkoms van die pastoraat bepaal, is daar ’n dringende noodsaak om die epistemologiese invloede op die pastorale teologie te evalueer. Die artikel fokus op die epistemologiese dinamika wat die pastoraat verander het van ’n skriftuurlike fundering na ’n kommunikatiewe handelingsteoretiese en postmoderne narratiewe strategie. Die navorsingsvraag is: Is ’n reformatoriese terugkeer na ’n bybels-gefundeerde pastoraat teen die agtergrond van die epistemologiese invloede nog moontlik? As a tribute to Prof. George Lotter on the occasion of his retirement and to his contribution to practical theology, this article focuses on the current situation of pastoral theology worldwide but mostly in South Africa. Since epistemological choices determine the method and content of research on pastoral theology, as well as the practical implementation thereof, there is an urgent need to evaluate the influences on pastoral theology and the results of these influences. The article focuses on the epistemological dynamics that have changed pastoral theology from a scriptural approach to a discipline of communicative acts and a postmodern strategy of narrative pastoral counselling. The research question is: Is it still possible to have a reformed pastoral theology and pastoral counselling against the backdrop of these epistemological changes?

  17. Synthesis, spectral, thermal, optical dispersion and dielectric ...

    Indian Academy of Sciences (India)

    of nanocrystalline dimer complex (PEPyr–diCd) thin films as novel organic semiconductor .... iments were obtained by diethyl ether diffusion to a solution in CH2Cl2. Pale brown ...... A F 2004 Phosphorus Sulfur Silicon Relat. Elem. 179 1251.

  18. FPGA BASED ASYNCHRONOUS PIPELINED MB-OFDM UWB TRANSMITTER BACKEND MODULES

    Directory of Open Access Journals (Sweden)

    M. Santhi

    2010-03-01

    Full Text Available In this paper, a novel scheme is proposed which comprises the advantages of asynchronous pipelining techniques and the advantages of FPGAs for implementing a 200Mbps MB-OFDM UWB transmitter digital backend modules. In asynchronous pipelined system, registers are used as in synchronous system. But they are controlled by handshaking signals. Since FPGAs are rich in registers, design and implementation of asynchronous pipelined MBOFDM UWB transmitter on FPGA using four-phase bundled-data protocol is considered in this paper. Novel ideas have also been proposed for designing asynchronous OFDM using Modified Radix-24 SDF and asynchronous interleaver using two RAM banks. Implementation has been performed on ALTERA STRATIX II EP2S60F1020C4 FPGA and it is operating at a speed of 350MHz. It is assured that the proposed MB-OFDM UWB system can be made to work on STRATIX III device with the operating frequency of 528MHz in compliance to the ECMA-368 standard. The proposed scheme is also applicable for FPGA from other vendors and ASIC.

  19. An ultrafast line-by-line algorithm for calculating spectral transmittance and radiance

    International Nuclear Information System (INIS)

    Tan, X.

    2013-01-01

    An ultrafast line-by-line algorithm for calculating spectral transmittance and radiance of gases is presented. The algorithm is based on fast convolution of the Voigt line profile using Fourier transform and a binning technique. The algorithm breaks a radiative transfer calculation into two steps: a one-time pre-computation step in which a set of pressure independent coefficients are computed using the spectral line information; a normal calculation step in which the Fourier transform coefficients of the optical depth are calculated using the line of sight information and the coefficients pre-computed in the first step, the optical depth is then calculated using an inverse Fourier transform and the spectral transmittance and radiance are calculated. The algorithm is significantly faster than line-by-line algorithms that do not employ special speedup techniques by a factor of 10 3 –10 6 . A case study of the 2.7 μm band of H 2 O vapor is presented. -- Highlights: •An ultrafast line-by-line model based on FFT and a binning technique is presented. •Computationally expensive calculations are factored out into a pre-computation step. •It is 10 3 –10 8 times faster than LBL algorithms that do not employ speedup techniques. •Good agreement with experimental data for the 2.7 μm band of H 2 O

  20. Radio frequency radiation (RFR) from TV and radio transmitters at a pilot region in Turkey.

    Science.gov (United States)

    Sirav, Bahriye; Seyhan, Nesrin

    2009-09-01

    For the last 30 y, the biological effects of non-ionising radiation (NIR: 0-300 GHz) have been a major topic in bioelectromagnetism. Since the number of radiofrequency (RF) systems operating in this frequency range has shown an incredible increase over the last few decades, the dangers of exposure to the fields generated thereby has become an important public health issue. In this study, the aim was to evaluate the level of RF electromagnetic radiation in Yenimahalle Sentepe Dededoruk Hill in Ankara, Turkey that is a multiple-transmitter site hosting 64 different TV and radio towers and one base station for mobile phone communication. The site has been of interest as it is nearby a residential community. Within the technical input data available on 31 of the radio and TV transmitters, the calculated radiation level in this particular region was found to be approximately four times higher than the permitted standards of Turkey, which are the same as the ICNIRP standards. Electromagnetic field measurement is needed in the site.

  1. Output Choice of a Chaotic Jerk Circuit Used as Transmitter in Data Secure Communications

    Directory of Open Access Journals (Sweden)

    DATCU, O.

    2015-11-01

    Full Text Available Usually, when analyzing a data series, dynamical systems theory is used to reconstruct the state space of the original system. This work aims to determine which of a chaotic system's states is best suited as output when transmitting secret messages. This is the first step prior to designing an actual communication scheme. As an example, the three states of Sprott's jerk circuit are analyzed in terms of the local observability they ensure for the original dynamics when transmitted as a scalar data series. Results show that its first two states enable accurate estimation of the transmitter's dynamics at the receiving end. However, its third state generates, in some regions of the state space, a non-invertible transformation between the original state space and the one the receiver sees. This is due to the exponential nonlinearities present in this state's derivatives. Given that these nonlinearities remain inaccessible to the receiver, they are neglected in order to allow the partial reconstruction of the dynamics of the transmitter. But, since these nonlinearities are essential for the chaotic behavior, this makes the third state unusable for cryptographic purposes. This analysis may be applied to any bipolar junction transistor or diode based chaotic circuit.

  2. Par and IR reflectance, transmittance, and absorptance of four crop canopies

    International Nuclear Information System (INIS)

    Wanjura, D.F.; Hatfield, J.L.

    1986-01-01

    Reflectance, transmittance and absorptance of electromagnetic radiation by cotton, soybeans, grain sorghum, and sunflower was measured at three growth stages in two wavebands (PAR: 0.4 to 0.7 pun and IR: 0.7 to 1.1 yim). As leaf area increased in each crop there were increases in IR reflectance and PAR absorptance and decreases in PAR reflectance and both PAR and IR transmittance. IR radiation was concentrated at the soil surface between rows by reflectance from the sides of canopies when crop cover was less than 80%. Across all crops one parameter, leaf overlap index, explained 81 and 71% of the PAR reflectance and another, crop cover, explained 86 and 94% of IR reflectance from rows and interrows, respectively. Attenuation of PAR radiation through the canopies of cotton and sunflower was similar (K = 0.62 and 0.67) but different from that of soybeans and grain sorghum (K = 0.46 and 0.43) which were the same

  3. Radio frequency radiation (RFR) from TV and radio transmitters at a pilot region in Turkey

    International Nuclear Information System (INIS)

    Sirav, B.; Seyhan, N.

    2009-01-01

    For the last 30 y, the biological effects of non-ionising radiation (NIR: 0-300 GHz) have been a major topic in bio-electromagnetism. Since the number of radiofrequency (RF) systems operating in this frequency range has shown an incredible increase over the last few decades, the dangers of exposure to the fields generated thereby has become an important public health issue. In this study, the aim was to evaluate the level of RF electromagnetic radiation in Yenimahalle Sentepe Dededoruk Hill in Ankara (Turkey) that is a multiple-transmitter site hosting 64 different TV and radio towers and one base station for mobile phone communication. The site has been of interest as it is nearby a residential community. Within the technical input data available on 31 of the radio and TV transmitters, the calculated radiation level in this particular region was found to be approximately four times higher than the permitted standards of Turkey, which are the same as the ICNIRP standards. Electromagnetic field measurement is needed in the site. (authors)

  4. Determination of the solar transmittance for the translucent shutter with PCM in liquid and solid state

    Science.gov (United States)

    Komerska, Anna; Ksionek, Dariusz; Rosiński, Marian

    2017-11-01

    This article presents results of the energy performance of an external translucent shading component integrated with a phase change material. A proposed technology is able to accumulate considerable amounts of energy in the latent heat by absorbing solar energy. Due to selective optical properties, much of the visible light is still transmitted through the facade. Experimental measurements were carried out in a laboratory set-up - testing thermal chamber, located in the Faculty of Building Services, Hydro and Environmental Engineering at Warsaw University of Technology. The main result of the experimental study was the evaluation of the average solar transmittance in the whole measured spectrum, as well as in the infrared and visible light. Since the shift in optical properties was observed when the material was undergoing a phase transition, the average spectral transmittances were measured for different states of matter of the PCM material. The tested shutter showed abilities to reduce and modulate daylight and solar heat gains in the indoor environment, which could contribute to considerable energy savings.

  5. Design of CMOS RFIC ultra-wideband impulse transmitters and receivers

    CERN Document Server

    Nguyen, Cam

    2017-01-01

    This book presents the design of ultra-wideband (UWB) impulse-based transmitter and receiver frontends, operating within the 3.1-10.6 GHz frequency band, using CMOS radio-frequency integrated-circuits (RFICs). CMOS RFICs are small, cheap, low power devices, better suited for direct integration with digital ICs as compared to those using III-V compound semiconductor devices. CMOS RFICs are thus very attractive for RF systems and, in fact, the principal choice for commercial wireless markets.  The book comprises seven chapters. The first chapter gives an introduction to UWB technology and outlines its suitability for high resolution sensing and high-rate, short-range ad-hoc networking and communications. The second chapter provides the basics of CMOS RFICs needed for the design of the UWB RFIC transmitter and receiver presented in this book. It includes the design fundamentals, lumped and distributed elements for RFIC, layout, post-layout simulation, and measurement. The third chapter discusses the basics of U...

  6. Rocket observations of the precipitation of electrons by ground VLF transmitters

    International Nuclear Information System (INIS)

    Arnoldy, R.L.; Kintner, P.M.

    1989-01-01

    Below an altitude of 400 km or less over the NASA Wallops Island range, stably trapped particles do not exist because of the South Atlantic Anomaly. In an experiment to measure scattered electrons at these altitudes (NASA flight 36:013), electron detectors clearly measured two monoenergetic electron peaks above the low background. The two monoernergetic peaks are attributed to the resonant interaction of electrons with VLF waves from Navy ground transmitters at Cutler, Maine, and Annapolis, Maryland. The transmitter signals were measured with electric and magnetic receivers aboard the rocket, and their propagation through the ionosphere and correlation with the precipitated electrons are discussed. In addition, energetic ions were also measured to be in the bounce loss cone during this rocket flight. Because of increased geomagnetic activity, it apears that the ring current extended inward to at least the L=2.5 magnetic shell and enhanced convection eroded the plasmasphere. The inward movement or compression of the plasmapause is consistent with a steep gradient in the equatorial cold plasma density and a localized equatorial interaction region needed to account for the monoenergetic elecrtron precipitation. The role of the geomagnetic activity in ''priming'' the trapped electron population for cyclotron resonance with VLF waves such that there is continuous scattering into the bounce loss cone remains uncertain. copyright American Geophysical Union 1989

  7. Performance Limits of Online Energy Harvesting Communications with Noisy Channel State Information at the Transmitter

    KAUST Repository

    Zenaidi, Mohamed Ridha

    2017-03-01

    In energy harvesting communications, the transceivers have to adjust the data transmission to the energy scavenged during the course of communication. The performance of the transmission depends on the channel conditions which vary randomly due to mobility and environmental changes. In this paper, we consider the problem of power allocation taking into account the energy arrivals over time and the quality of channel state information (CSI) measured at the transmitter, in order to maximize the throughput. Differently from previous work, we focus on energy harvesting communications where the CSI at the transmitter is not perfect and may include estimation errors. In the present paper, we introduce a Markov process that models the energy arrival process. Indeed, we solve the throughput maximization problem with respect to energy harvesting constraints. We show that the optimal online power policy can be found using dynamic programming. Furthermore, we study the asymptotic behavior of the communication system at low and high average recharge rate (ARR) regime. Selected numerical results are provided to support our analysis.

  8. Determination of the solar transmittance for the translucent shutter with PCM in liquid and solid state

    Directory of Open Access Journals (Sweden)

    Komerska Anna

    2017-01-01

    Full Text Available This article presents results of the energy performance of an external translucent shading component integrated with a phase change material. A proposed technology is able to accumulate considerable amounts of energy in the latent heat by absorbing solar energy. Due to selective optical properties, much of the visible light is still transmitted through the facade. Experimental measurements were carried out in a laboratory set–up – testing thermal chamber, located in the Faculty of Building Services, Hydro and Environmental Engineering at Warsaw University of Technology. The main result of the experimental study was the evaluation of the average solar transmittance in the whole measured spectrum, as well as in the infrared and visible light. Since the shift in optical properties was observed when the material was undergoing a phase transition, the average spectral transmittances were measured for different states of matter of the PCM material. The tested shutter showed abilities to reduce and modulate daylight and solar heat gains in the indoor environment, which could contribute to considerable energy savings.

  9. Effects of telemetry transmitter placement on egg retention in naturally spawning, captively reared steelhead

    International Nuclear Information System (INIS)

    Berejikian, Barry A.; Brown, Richard S.; Tatara, Chris P.; Cooke, Steven J.

    2007-01-01

    Maturing female anadromous salmonids receiving surgical intraperitoneally-implanted telemetry transmitters may experience difficulty depositing eggs during natural spawning. We allocated maturing adult steelhead females to three treatments: tags surgically implanted in the body cavity (internal), tags implanted between the skin and muscle tissue (subdermal), and non-tagged, and allowed them to spawn naturally in an experimental channel. Internally tagged females retained significantly more eggs than both the subdermally tagged treatment (P = 0.005) and non-tagged controls (P = 0.001); the subdermal and non-tag controls did not differ significantly (P = 0.934). The internal, subdermal and non-tag treatments retained an average of 49%, 11% and 2% of their eggs, respectively. The onset of sexual activity did not differ significantly among treatments (P = 0.413). Post-spawning mortality was 70% for both internally and subdermally tagged females and 0% for non-tagged females (P <0.01). We suggest that subdermal implantation techniques be considered in future studies during the reproductive period to reduce egg retention caused by internal implantation of transmitters

  10. Analysis of transmittance properties in 1D hybrid dielectric photonic crystal containing superconducting thin films

    Science.gov (United States)

    Soltani, Osswa; Zaghdoudi, Jihene; Kanzari, Mounir

    2018-06-01

    By means of two fluid model and transfer matrix method (TMM), we investigate theoretically the transmittance properties of a defective hybrid dielectric-dielectric photonic crystal that contains a superconducting material as a defect layer. The considered hybrid photonic structure is: H(LH) 7(HLSLH) P H(LH) 7 , where H is the high refractive index dielectric, L is the low refractive index dielectric, S is the superconducting material and P is the repetitive number. The results show that the variation of the number and the positions of the transmissions modes depend strongly on the repetitive number P, the temperature T and the thickness of the layer S. An improvement of the spectral response is obtained with the exponential gradation of layer thicknesses dj =d0 + βejα , where d0 is the initial thickness of the layer j, α and β are two particular constants for each material. In addition, the effect of the incident angle for both transverse electric (TE) and transverse magnetic (TM) polarizations on the transmittance spectrum is discussed. As a result, we propose a tunable narrow stop-band polychromatic filter that covers the visible wavelength.

  11. Effects of telemetry transmitter placement on egg retention in naturally spawning, captively reared steelhead

    Energy Technology Data Exchange (ETDEWEB)

    Berejikian, Barry A.; Brown, Richard S.; Tatara, Chris P.; Cooke, Steven J.

    2007-05-01

    Maturing female anadromous salmonids receiving surgical intraperitoneally-implanted telemetry transmitters may experience difficulty depositing eggs during natural spawning. We allocated maturing adult steelhead females to three treatments: tags surgically implanted in the body cavity (internal), tags implanted between the skin and muscle tissue (subdermal), and non-tagged, and allowed them to spawn naturally in an experimental channel. Internally tagged females retained significantly more eggs than both the subdermally tagged treatment (P = 0.005) and non-tagged controls (P = 0.001); the subdermal and non-tag controls did not differ significantly (P = 0.934). The internal, subdermal and non-tag treatments retained an average of 49%, 11% and 2% of their eggs, respectively. The onset of sexual activity did not differ significantly among treatments (P = 0.413). Post-spawning mortality was 70% for both internally and subdermally tagged females and 0% for non-tagged females (P <0.01). We suggest that subdermal implantation techniques be considered in future studies during the reproductive period to reduce egg retention caused by internal implantation of transmitters.

  12. Three-dimensional mapping of light transmittance and foliage distribution using lidar

    International Nuclear Information System (INIS)

    Todd, K.W.; Csillag, F.; Atkinson, P.M.

    2003-01-01

    The horizontal and vertical distributions of light transmittance were evaluated as a function of foliage distribution using lidar (light detection and ranging) observations for a sugar maple (Acer saccharum) stand in the Turkey Lakes Watershed. Along the vertical profile of vegetation, horizontal slices of probability of light transmittance were derived from an Optech ALTM 1225 instrument's return pulses (two discrete, 15-cm diameter returns) using indicator kriging. These predictions were compared with (i) below canopy (1-cm spatial resolution) transect measurements of the fraction of photosynthetically active radiation (FPAR) and (ii) measurements of tree height. A first-order trend was initially removed from the lidar returns. The vertical distribution of vegetation height was then sliced into nine percentiles and indicator variograms were fitted to them. Variogram parameters were found to vary as a function of foliage height above ground. In this paper, we show that the relationship between ground measurements of FPAR and kriged estimates of vegetation cover becomes stronger and tighter at coarser spatial resolutions. Three-dimensional maps of foliage distribution were computed as stacks of the percentile probability surfaces. These probability surfaces showed correspondence with individual tree-based observations and provided a much more detailed characterization of quasi-continuous foliage distribution. These results suggest that discrete-return lidar provides a promising technology to capture variations of foliage characteristics in forests to support the development of functional linkages between biophysical and ecological studies. (author)

  13. A modeling approach to predict acoustic nonlinear field generated by a transmitter with an aluminum lens.

    Science.gov (United States)

    Fan, Tingbo; Liu, Zhenbo; Chen, Tao; Li, Faqi; Zhang, Dong

    2011-09-01

    In this work, the authors propose a modeling approach to compute the nonlinear acoustic field generated by a flat piston transmitter with an attached aluminum lens. In this approach, the geometrical parameters (radius and focal length) of a virtual source are initially determined by Snell's refraction law and then adjusted based on the Rayleigh integral result in the linear case. Then, this virtual source is used with the nonlinear spheroidal beam equation (SBE) model to predict the nonlinear acoustic field in the focal region. To examine the validity of this approach, the calculated nonlinear result is compared with those from the Westervelt and (Khokhlov-Zabolotskaya-Kuznetsov) KZK equations for a focal intensity of 7 kW/cm(2). Results indicate that this approach could accurately describe the nonlinear acoustic field in the focal region with less computation time. The proposed modeling approach is shown to accurately describe the nonlinear acoustic field in the focal region. Compared with the Westervelt equation, the computation time of this approach is significantly reduced. It might also be applicable for the widely used concave focused transmitter with a large aperture angle.

  14. Probability of acoustic transmitter detections by receiver lines in Lake Huron: results of multi-year field tests and simulations

    Science.gov (United States)

    Hayden, Todd A.; Holbrook, Christopher M.; Binder, Thomas; Dettmers, John M.; Cooke, Steven J.; Vandergoot, Christopher S.; Krueger, Charles C.

    2016-01-01

    BackgroundAdvances in acoustic telemetry technology have led to an improved understanding of the spatial ecology of many freshwater and marine fish species. Understanding the performance of acoustic receivers is necessary to distinguish between tagged fish that may have been present but not detected and from those fish that were absent from the area. In this study, two stationary acoustic transmitters were deployed 250 m apart within each of four acoustic receiver lines each containing at least 10 receivers (i.e., eight acoustic transmitters) located in Saginaw Bay and central Lake Huron for nearly 2 years to determine whether the probability of detecting an acoustic transmission varied as a function of time (i.e., season), location, and distance between acoustic transmitter and receiver. Distances between acoustic transmitters and receivers ranged from 200 m to >10 km in each line. The daily observed probability of detecting an acoustic transmission was used in simulation models to estimate the probability of detecting a moving acoustic transmitter on a line of receivers.ResultsThe probability of detecting an acoustic transmitter on a receiver 1000 m away differed by month for different receiver lines in Lake Huron and Saginaw Bay but was similar for paired acoustic transmitters deployed 250 m apart within the same line. Mean probability of detecting an acoustic transmitter at 1000 m calculated over the study period varied among acoustic transmitters 250 m apart within a line and differed among receiver lines in Lake Huron and Saginaw Bay. The simulated probability of detecting a moving acoustic transmitter on a receiver line was characterized by short periods of time with decreased detection. Although increased receiver spacing and higher fish movement rates decreased simulated detection probability, the location of the simulated receiver line in Lake Huron had the strongest effect on simulated detection probability.ConclusionsPerformance of receiver

  15. Effect of high-energy electron beam irradiation on the transmittance of ZnO thin films on transparent substrates

    International Nuclear Information System (INIS)

    Yun, Eui-Jung; Jung, Jin-Woo; Han, Young-Hwan; Kim, Min-Wan; Lee, Byung Cheol

    2010-01-01

    We investigated in this study the effects of high-energy electron beam irradiation (HEEBI) on the optical transmittance of undoped ZnO films grown on transparent substrates, such as corning glass and polyethersulfone (PES) plastic substrates, with a radio frequency (rf) magnetron sputtering technique. The ZnO thin films were treated with HEEBI in air at RT with an electron beam energy of 1 MeV and doses of 4.7 x 10 14 - 4.7 x 10 16 electrons/cm 2 . The optical transmittance of the ZnO films was measured using an ultraviolet visible near-infrared spectrophotometer. The detailed estimation process for separating the transmittance of HEEBI-treated ZnO films from the total transmittance of ZnO films on transparent substrates treated with HEEBI is given in this paper. We concluded that HEEBI causes a slight suppression in the optical transmittance of ZnO thin films. We also concluded that HEEBI treatment with a high dose shifted the optical band gap (E g ) toward the lower energy region from 3.29 to 3.28 eV whereas that with a low dose unchanged E g at 3.25 eV. This shift suggested that HEEBI at RT at a high dose acts like an annealing treatment at high temperature.

  16. Influence of opalescence and fluorescence properties on the light transmittance of resin composite as a function of wavelength.

    Science.gov (United States)

    Lee, Yong-Keun; Powers, John M

    2006-10-01

    To determine the influence of opalescence and fluorescence properties on the light transmittance of resin composites as a function of wavelength (410-750 nm). Spectral distribution of seven resin composites of A2 shade was measured according to the CIELAB color scale relative to the standard illuminant D65 in the reflectance and transmittance modes. Opalescence spectrum (OPS) was calculated as the subtraction spectrum (i.e., the spectrum measured in the transmittance mode subtracted at each wavelength from the spectrum measured in the reflectance mode). UV component of the illuminant was included and excluded to calculate the fluorescence spectrum (FLR and FLT in the reflectance and transmittance mode, respectively). Contrast ratio (CR) was calculated as the ratio of reflectance over a black background and over a white background. The total transmittance spectral distribution (TSD) value was used as the parameter to indicate masking ability of the resin composites over background color. Multiple regression analyses were performed among TSD and other optical parameters at the significance level of 0.05. In all the resin composites and wavelength range, correlation between CR and TSD was very high (r = -0.99). Correlations between each parameters varied by the wavelength range of fluorescence (410-500 nm) and no-fluorescence (510-750 nm). Correlation between OPS and TSD varied by the wavelength range (r = -0.86 to -0.94, Popalescence and fluorescence of resin composite varied by the wavelength.

  17. Influence of Incision Location on Transmitter Loss, Healing, Incision Lengths, Suture Retention, and Growth of Juvenile Chinook Salmon

    Energy Technology Data Exchange (ETDEWEB)

    Panther, Jennifer L.; Brown, Richard S.; Gaulke, Greggory L.; Woodley, Christa M.; Deters, Katherine A.

    2010-05-11

    In this study, conducted by Pacific Northwest National Laboratory for the U.S. Army Corps of Engineers, Portland District, we measured differences in survival and growth, incision openness, transmitter loss, wound healing, and erythema among abdominal incisions on the linea alba, lateral and parallel to the linea alba (muscle-cutting), and following the underlying muscle fibers (muscle-sparing). A total of 936 juvenile Chinook salmon were implanted with both Juvenile Salmon Acoustic Tracking System transmitters (0.43 g dry) and passive integrated transponder tags. Fish were held at 12°C (n = 468) or 20°C (n = 468) and examined once weekly over 98 days. We found survival and growth did not differ among incision groups or between temperature treatment groups. Incisions on the linea alba had less openness than muscle-cutting and muscle-sparing incisions during the first 14 days when fish were held at 12°C or 20°C. Transmitter loss was not different among incision locations by day 28 when fish were held at 12°C or 20°C. However, incisions on the linea alba had greater transmitter loss than muscle-cutting and muscle-sparing incisions by day 98 at 12°C. Results for wound closure and erythema differed among temperature groups. Results from our study will be used to improve fish-tagging procedures for future studies using acoustic or radio transmitters.

  18. Godsdiens: Middel tot verslawing of tot heling? | Coetzer | Acta ...

    African Journals Online (AJOL)

    There are two sides to religion, on the one hand the threat that implies emotional pain and addiction, on the other hand the healing and liberating effect of a balanced and healthy religion. In this article the focus is on the former. Factors which render people vulnerable to spiritual addiction are put on the table. Similarities ...

  19. Tot Graeci Tot Sententiae: Astronomical Perspective Multiplicity in Ancient Greece

    Science.gov (United States)

    Longo, O.

    2011-06-01

    Ancient Greece was made of a multiplicity of thinking heads, in an atmosphere of (relative) freedom of opinions, in every field of knowledge. then we should not wonder if many astronomical and cosmological theories, survived until our 17th century, had already been formulated by different philosophers and in different regions, cities and periods of Greek history. Geocentric and heliocentric theories, as well as an atomistic theory of an infinite universe (with infinite worlds), could survive without crashing with one another. In the same time, religious opinions regarding the planets and Sun as a series of gods were present, however not on a scientific ground.

  20. Qualification testing of fiber-based laser transmitters and on-orbit validation of a commercial laser system

    Science.gov (United States)

    Wright, M. W.; Wilkerson, M. W.; Tang, R. R.

    2017-11-01

    Qualification testing of fiber based laser transmitters is required for NASA's Deep Space Optical Communications program to mature the technology for space applications. In the absence of fully space qualified systems, commercial systems have been investigated in order to demonstrate the robustness of the technology. To this end, a 2.5 W fiber based laser source was developed as the transmitter for an optical communications experiment flown aboard the ISS as a part of a technology demonstration mission. The low cost system leveraged Mil Standard design principles and Telcordia certified components to the extent possible and was operated in a pressure vessel with active cooling. The laser was capable of high rate modulation but was limited by the mission requirements to 50 Mbps for downlinking stored video from the OPALS payload, externally mounted on the ISS. Environmental testing and space qualification of this unit will be discussed along with plans for a fully space qualified laser transmitter.

  1. Gigascale Silicon Photonic Transmitters Integrating HBT-based Carrier-injection Electroabsorption Modulator Structures

    Science.gov (United States)

    Fu, Enjin

    Demand for more bandwidth is rapidly increasing, which is driven by data intensive applications such as high-definition (HD) video streaming, cloud storage, and terascale computing applications. Next-generation high-performance computing systems require power efficient chip-to-chip and intra-chip interconnect yielding densities on the order of 1Tbps/cm2. The performance requirements of such system are the driving force behind the development of silicon integrated optical interconnect, providing a cost-effective solution for fully integrated optical interconnect systems on a single substrate. Compared to conventional electrical interconnect, optical interconnects have several advantages, including frequency independent insertion loss resulting in ultra wide bandwidth and link latency reduction. For high-speed optical transmitter modules, the optical modulator is a key component of the optical I/O channel. This thesis presents a silicon integrated optical transmitter module design based on a novel silicon HBT-based carrier injection electroabsorption modulator (EAM), which has the merits of wide optical bandwidth, high speed, low power, low drive voltage, small footprint, and high modulation efficiency. The structure, mechanism, and fabrication of the modulator structure will be discussed which is followed by the electrical modeling of the post-processed modulator device. The design and realization of a 10Gbps monolithic optical transmitter module integrating the driver circuit architecture and the HBT-based EAM device in a 130nm BiCMOS process is discussed. For high power efficiency, a 6Gbps ultra-low power driver IC implemented in a 130nm BiCMOS process is presented. The driver IC incorporates an integrated 27-1 pseudo-random bit sequence (PRBS) generator for reliable high-speed testing, and a driver circuit featuring digitally-tuned pre-emphasis signal strength. With outstanding drive capability, the driver module can be applied to a wide range of carrier

  2. Correlation of light transmittance with asthma attack: fine water particles as a possible inducing factor of asthma.

    Science.gov (United States)

    Kanaya, Kazuo; Okamoto, Koji; Shimbo, Shinichiro; Ikeda, Masayuki

    2011-01-01

    It has been postulated that air-borne fine water particles (or mist) can induce asthma attacks in asthmatic children. To date, no attempt has been made to quantify the density of air-borne fine water particles with the aim of relating particle density to the etiology of asthma among children. The aim of this study was to investigate the relation of asthma attack frequency and the particle density evaluated in terms of light transmittance. The density of fine water particles was quantified by measuring reductions in light transmittance at 250, 365 and 580 nm at an outdoor location when the surroundings were in darkness. The measurements were made at distances varying from 1 to 3 m from the light sources and performed every morning and evening for 1 year. Each day was separated into two half-day units [i.e., morning (from midnight to noon) and afternoon (from noon to midnight)]. The number of asthma attacks among 121 enrolled asthmatic children was counted for each unit. A possible correlation between the transmittance reduction and frequency of asthma attacks was assessed. A significant difference was observed in the extent of reduction in light transmittance at 365 nm between the units with asthma attacks and those without attacks. Furthermore, the reduction in the transmittance was more evident when more asthma attacks were recorded among the patients. No difference was detected in the reduction in light transmittance at 250 or 580 nm. These results support the hypothesis that air-borne fine water particles are among the etiological factors that induce asthma attacks in asthmatic children.

  3. Thickness dependence of light transmittance, translucency and opalescence of a ceria-stabilized zirconia/alumina nanocomposite for dental applications.

    Science.gov (United States)

    Shiraishi, Takanobu; Watanabe, Ikuya

    2016-05-01

    This study was conducted to investigate thickness dependence of light transmittance, translucency and opalescence of a commercially available fully-sintered ceria-stabilized zirconia/alumina nanocomposite for dental all-ceramic restorations. Three disk samples of 16 mm in diameter and thickness ranging from 0.2 to 0.6 mm with 0.1 mm increment each were cut from a fully-sintered rod-shaped Ce-TZP/alumina nanocomposite (NANOZR, Panasonic Healthcare, Japan) and polished flat by using diamond slurry. Spectral light transmittance data under the CIE standard illuminant D65 were recorded at 10nm intervals from 360 to 740 nm using a computer-controlled spectrophotometer. Average transmittance, translucency and opalescence parameters were determined as a function of sample thickness. Optical properties of a fully-sintered yttria-stabilized tetragonal zirconia polycrystals (Cercon(®) base, DeguDent GmbH, Germany) were also investigated as a reference. Two-way ANOVA was performed to determine the significant differences in various optical parameters among types of ceramic and thicknesses at α=0.05. Results of the two-way ANOVA showed that the average transmittance, translucency and opalescence parameters of both ceramic materials were significantly influenced by the type of ceramic and thickness (popalescence parameters exceeding 20 CIE units when the sample thickness was nearly 0.3 mm. The prominent characteristics of high opalescence and low transmittance of light in the NANOZR was considered to be caused by its specific very fine interpenetrated intragranular microstructure and by a large difference of refractive indices of Ce-TZP and alumina components. High opalescence and low transmittance of light of the ceria-stabilized zirconia/alumina nanocomposite (NANOZR) are attractive properties for use as a substructure in fabricating porcelain-veneering-type esthetic all-ceramic restorations. Copyright © 2016 Academy of Dental Materials. Published by Elsevier Ltd. All

  4. 'Verleid consumenten tot gezond gedrag'

    NARCIS (Netherlands)

    Trijp, van J.C.M.

    2008-01-01

    Dat de gemiddelde Nederlander niet gezond leeft, dat is ondertussen bekend. Maar wat doe je eraan? Met marketing kom je een heel eind, weet Hans van Trijp, hoogleraar bij de Wageningse leerstoelgroep Marktkunde en consumentengedrag

  5. Tekslinguistiek: van teorie tot praktyk

    Directory of Open Access Journals (Sweden)

    S. Prinsloo

    2002-08-01

    Full Text Available Text linguistics: From theory to practice In this article it is argued that theory and practice are reconcilable in the case of text linguistics and the teaching of writing skills. First, text linguistics as a theoretical discipline is explained. Text linguistics, according to De Beaugrande and Dressler (1981, focuses on the seven constitutive principles, as well as the three regulative principles of textuality that determine the linguistic quality or standard of a text. The constitutive principles are cohesion, which in its turn, can be obtained by means of reference, ellipsis, substitution, conjunction and lexical cohesion, coherence, intentionality, acceptability, information, contextuality and intertextuality. The three regulative principles are efficiency, effectiveness and appropriateness. This is followed by a discussion of the relationship between text linguistics and the teaching of writing skills. Knowledge of the principles of text linguistics enables the teacher of writing skills to evaluate texts and to make learners aware of the properties of a “good” text, resulting in effective communication. Text-linguistic concepts are then applied to texts created by Afrikaans second-language speakers. It is then indicated how knowledge of text-linguistic concepts can be an aid in the teaching of writing skills.

  6. Breaking the Transmitter-Receiver Isolation Barrier in Mobile Handsets with Spatial Duplexing

    DEFF Research Database (Denmark)

    Alrabadi, Osama; Tatomirescu, Alexandru; Knudsen, Mikael

    2013-01-01

    In full-duplex radio communication systems like eUTRAN, CDMA-2000, the radio transmitter (Tx) is active at the same time as the radio receiver (Rx). The Tx and the Rx will be using separate dedicated frequency bands and the Tx-Rx isolation is ensured by duplex filters. However, agile duplexers...... required for multiband operation are almost non-existent while dedicating a bank of narrowband filters is bulky and incurs considerable switching losses. In this article we propose an approach that dramatically reduces the complexity of the RF frontend, first by replacing the duplex filter with a spatial...... frequency bands as long as the antennas are made tunable. Moreover, the spatial filter may directly benefit from the balanced architecture of the power amplifiers (PAs) thus reducing the total system complexity and insertion loss. Finally, simulation and initial measurement results are provided...

  7. Thermal Transmittance and the Embodied Energy of Timber Frame Lightweight Walls Insulated with Straw and Reed

    Science.gov (United States)

    Miljan, M.; Miljan, J.

    2015-11-01

    Sustainable energy use has become topical in the whole world. Energy gives us comfort we are used to. EU and national regulations determine energy efficiency of the buildings. This is one side of the problem - energy efficiency of houses during exploitation. But the other side is primary energy content of used materials and more rational use of resources during the whole life cycle of a building. The latter value constitutes about 8 - 20% from the whole energy content. Calculations of energy efficiency of materials lead us to energy efficiency of insulation materials and to comparison of natural and industrial materials taking into account their thermal conductivity as well as their primary energy content. Case study of the test house (built in 2012) insulated with straw bales gave the result that thermal transmittance of investigated straw bale walls was according to the minimum energy efficiency requirements set in Estonia U = 0.12 - 0.22 W/m2K (for walls).

  8. Determination of adsorbed protein concentration in aluminum hydroxide suspensions by near-infrared transmittance Spectroscopy

    DEFF Research Database (Denmark)

    Lai, Xuxin; Zheng, Yiwu; Jacobsen, Susanne

    2008-01-01

    , using the partial least square regression (PLSR) method to construct a calibration model. The linear concentration range of adsorbed BSA is from 0 to 1.75 mg/mL by using 10 mm path length cuvettes. The influence of the sedimentation in suspension, different buffers, and different aluminum hydroxide......Analysis of aluminum hydroxide based vaccines is difficult after antigen adsorption. Adsorbed protein is often assessed by measuring residual unadsorbed protein for quality control. A new method for the direct determination of adsorbed protein concentration in suspension using near-infrared (NIR......) transmittance spectroscopy is proposed here. A simple adsorption system using albumin from bovine serum (BSA) and aluminum hydroxide as a model system is employed. The results show that the NIR absorbance at 700-1300 nm is correlated to the adsorbed BSA concentration, measured by the ultraviolet (UV) method...

  9. A 94 GHz CMOS based oscillator transmitter with an on-chip meandered dipole antenna

    KAUST Repository

    Cheema, Hammad M.

    2015-10-26

    A miniaturized 94 GHz oscillator transmitter in 65nm CMOS is presented. An extremely small silicon foot-print of 0.25mm2 is achieved through meandering of the top-metal dipole antenna, conjugate matching between the oscillator and the antenna without impedance matching elements and efficient placement of the oscillator circuit within the antenna. The antenna demonstrates bandwidth of 90 to 99 GHz (10%) and a gain of -6dBi. The use of parasitic aware antenna-circuit code-sign strategy results in an accurate measured oscillation frequency of 94.1 GHz. The oscillator exhibits a measured output power of -25 dBm, phase noise of -88 dBc/Hz at 1 MHz offset and consumes 8.4mW from a 1V supply. © 2015 IEEE.

  10. A global network topology of stock markets: Transmitters and receivers of spillover effects

    Science.gov (United States)

    Shahzad, Syed Jawad Hussain; Hernandez, Jose Areola; Rehman, Mobeen Ur; Al-Yahyaee, Khamis Hamed; Zakaria, Muhammad

    2018-02-01

    This paper applies a bivariate cross-quantilogram approach to examine the spillover network structure in the stock markets of 58 countries according to bearish, normal and bullish market scenarios. Our aim is to identify the strongest interdependencies, the directionality of the spillover risk effects, and to detect those equity markets with the potential to cause global systemic risk. The results highlight the role of the US and Canadian equity markets as major spillover transmitters, while the stock markets of Romania, Taiwan and Mexico act mainly as spillover receivers. Particularly strong spillovers are observed from the Canadian and US equity markets towards the Irish market, and from the Brazilian equity market towards the Kenyan equivalent. The equity market networks suggest that only the US equity market can trigger systemic risk on a global scale. Implications of the results are discussed.

  11. A High Optical Transmittance and Low Cost Touch Screen without Patterning

    Directory of Open Access Journals (Sweden)

    SAMADZAMINI, K.

    2017-02-01

    Full Text Available Transparent Conducting Oxide (TCO materials such as Fluorine Tin Oxide (FTO and Indium Tin Oxide (ITO due to their optical and electrical properties are used in touch screens as electrodes and wires. This paper proposes a novel technique of using Electrical Resistivity Tomography (ERT method in order to produce touch screens without pattering. Unlike existing techniques, the proposed methodology employs a uniform TCO coated screen with a maximum optical transmittance to convert the touch point coordinates into side electrodes voltages. The performance of the proposed method is tested experimentally on a FTO coated glass with a sheet resistance of 20 ohms/sq. The proposed methodology is found to be less complicated and low cost, since no pattern or electrodes are implemented in the display area.

  12. Nanosecond-level time synchronization of AERA using a beacon reference transmitter and commercial airplanes

    Directory of Open Access Journals (Sweden)

    Huege Tim

    2017-01-01

    Full Text Available Radio detection of cosmic-ray air showers requires time synchronization of detectors on a nanosecond level, especially for advanced reconstruction algorithms based on the wavefront curvature and for interferometric analysis approaches. At the Auger Engineering Radio Array, the distributed, autonomous detector stations are time-synchronized via the Global Positioning System which, however, does not provide sufficient timing accuracy. We thus employ a dedicated beacon reference transmitter to correct for eventby-event clock drifts in our offline data analysis. In an independent cross-check of this “beacon correction” using radio pulses emitted by commercial airplanes, we have shown that the combined timing accuracy of the two methods is better than 2 nanoseconds.

  13. GTAG: architecture and design of miniature transmitter with position logging for radio telemetry

    Science.gov (United States)

    Řeřucha, Šimon; Bartonička, Tomáš; Jedlička, Petr

    2011-10-01

    The radio telemetry is a well-known technique used within zoological research to exploit the behaviour of animal species. A usage of GPS for a frequent and precise position recording gives interesting possibility for a further enhancement of this method. We present our proposal of an architecture and design concepts of telemetry transmitter with GPS module, called GTAG, that is suited for study of the Egyptian fruit bat (Rousettus aegyptiacus). The model group we study set particular constrains, especially the weight limit (9 g) and prevention of any power resources recharging technique. We discuss the aspect of physical realization and the energyconsumption issues. We have developed a reference implementation that has been already deployed during telemetry sessions and we evaluate the experience and compare the estimated performance of our device to a real data.

  14. A Potential Transmitter Architecture for Future Generation Green Wireless Base Station

    Directory of Open Access Journals (Sweden)

    Mike Faulkner

    2009-01-01

    Full Text Available Current radio frequency power amplifiers in 3G base stations have very high power consumption leading to a hefty cost and negative environmental impact. In this paper, we propose a potential architecture design for future wireless base station. Issues associated with components of the architecture are investigated. The all-digital transmitter architecture uses a combination of envelope elimination and restoration (EER and pulse width modulation (PWM/pulse position modulation (PPM modulation. The performance of this architecture is predicted from the measured output power and efficiency curves of a GaN amplifier. 57% efficiency is obtained for an OFDM signal limited to 8 dB peak to average power ratio. The PWM/PPM drive signal is generated using the improved Cartesian sigma delta techniques. It is shown that an RF oversampling by a factor of four meets the WLAN spectral mask, and WCDMA specification is met by an RF oversampling of sixteen.

  15. Characterization of poly(3,4-ethylenedioxythiophene):tosylate conductive polymer microelectrodes for transmitter detection

    DEFF Research Database (Denmark)

    Larsen, Simon T.; Vreeland, Richard F.; Heien, Michael L.

    2012-01-01

    applications such as capillary electrophoresis, high-performance liquid chromatography, and constant potential amperometry at living cells. Band electrodes with widths down to 3 μm were fabricated on polymer substrates using UV lithographic methods. The electrodes are electrochemically stable in a range......In this paper we investigate the physical and electrochemical properties of micropatterned poly(3,4-ethylenedioxythiophene):tosylate (PEDOT:tosylate) microelectrodes for neurochemical detection. PEDOT:tosylate is a promising conductive polymer electrode material for chip-based bioanalytical...... between −200 mV and 700 mV vs. Ag/AgCl and show a relatively low resistance. A wide range of transmitters is shown to oxidize readily on the electrodes. Kinetic rate constants and half wave potentials are reported. The capacitance per area was found to be high (1670 ± 130 μF cm−2) compared to other thin...

  16. Improved Magnetron Stability and Reduced Noise in Efficient Transmitters for Superconducting Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Kazakevich, G. [MUONS Inc., Batavia; Johnson, R. [MUONS Inc., Batavia; Lebedev, V. [Fermilab; Yakovlev, V. [Fermilab

    2018-04-01

    State of the art high-current superconducting accelerators require efficient RF sources with a fast dynamic phase and power control. This allows for compensation of the phase and amplitude deviations of the accelerating voltage in the Superconducting RF (SRF) cavities caused by microphonics, etc. Efficient magnetron transmitters with fast phase and power control are attractive RF sources for this application. They are more cost effective than traditional RF sources such as klystrons, IOTs and solid-state amplifiers used with large scale accelerator projects. However, unlike traditional RF sources, controlled magnetrons operate as forced oscillators. Study of the impact of the controlling signal on magnetron stability, noise and efficiency is therefore important. This paper discusses experiments with 2.45 GHz, 1 kW tubes and verifies our analytical model which is based on the charge drift approximation.

  17. Gap energy studied by optical transmittance in lead iodide monocrystals grown by Bridgman's Method

    Directory of Open Access Journals (Sweden)

    Veissid N.

    1999-01-01

    Full Text Available The bandgap energy as a function of temperature has been determined for lead iodide. The monocrystal was obtained in a vacuum sealed quartz ampoule inside a vertical furnace by Bridgman's method. The optical transmittance measurement enables to evaluate the values of Eg. By a fitting procedure of Eg as a function of temperature is possible to extract the parameters that govern its behavior. The variation of Eg with temperature was determined as: Eg(T = Eg(0 - aT2/(a + T, with: Eg(0 = (2.435 ± 0.008 eV, a = (8.7 ± 1.3 x 10-4 eV/K and a = (192 ± 90 K. The bandgap energy of lead iodide at room temperature was found to be 2.277 ± 0.007 eV.

  18. Low-power DAC-less PAM-4 transmitter using a cascaded microring modulator.

    Science.gov (United States)

    Dubé-Demers, Raphaël; LaRochelle, Sophie; Shi, Wei

    2016-11-15

    Future super-computer interconnect systems and data centers request ultrahigh data rate links at low cost and power consumption, for which transmitters with a high level of integration and spectral efficient formats are key components. We report 60 Gb/s pulse-amplitude modulation (PAM-4) of an optical signal using a dual-microring silicon photonics circuit, making a low-power, digital-to-analog converter (DAC)-less PAM modulator. The power consumption is evaluated below 100 fJ/bit, including thermal adjustments. To the best of our knowledge, these results feature the lowest reported power consumption for PAM signaling in a DAC-less scheme for data rate beyond 40 Gb/s.

  19. Nanosecond-level time synchronization of AERA using a beacon reference transmitter and commercial airplanes

    Science.gov (United States)

    Huege, Tim

    2017-03-01

    Radio detection of cosmic-ray air showers requires time synchronization of detectors on a nanosecond level, especially for advanced reconstruction algorithms based on the wavefront curvature and for interferometric analysis approaches. At the Auger Engineering Radio Array, the distributed, autonomous detector stations are time-synchronized via the Global Positioning System which, however, does not provide sufficient timing accuracy. We thus employ a dedicated beacon reference transmitter to correct for eventby-event clock drifts in our offline data analysis. In an independent cross-check of this "beacon correction" using radio pulses emitted by commercial airplanes, we have shown that the combined timing accuracy of the two methods is better than 2 nanoseconds.

  20. A Potential Transmitter Architecture for Future Generation Green Wireless Base Station

    Directory of Open Access Journals (Sweden)

    Cijvat Ellie

    2009-01-01

    Full Text Available Abstract Current radio frequency power amplifiers in 3G base stations have very high power consumption leading to a hefty cost and negative environmental impact. In this paper, we propose a potential architecture design for future wireless base station. Issues associated with components of the architecture are investigated. The all-digital transmitter architecture uses a combination of envelope elimination and restoration (EER and pulse width modulation (PWM/pulse position modulation (PPM modulation. The performance of this architecture is predicted from the measured output power and efficiency curves of a GaN amplifier. 57% efficiency is obtained for an OFDM signal limited to 8 dB peak to average power ratio. The PWM/PPM drive signal is generated using the improved Cartesian sigma delta techniques. It is shown that an RF oversampling by a factor of four meets the WLAN spectral mask, and WCDMA specification is met by an RF oversampling of sixteen.

  1. Pressure transmitters: Addressing post-Fukushima regulations and requirements with Bibloc technology by Rolls-Royce

    International Nuclear Information System (INIS)

    Fabbro, Herve; Desgeorge, Romain; Chowanek, Michel

    2013-06-01

    Nuclear power stations are designed to withstand substantial seismic activity and as such represent some of the most robust buildings in the world. However The Fukushima nuclear incident highlighted the potential vulnerability of nuclear power plants when multiple natural events of historic proportions happen simultaneously. Following the incident, the worldwide nuclear industry quite rightly called for an immediate review and a targeted reassessment of the safety margins of nuclear reactors. Several recommendations have been given by international safety authorities, including a significant toughening of the already stringent regulations and requirements, with respect to earthquakes, extreme temperatures, pressure and radiation resistance. In the event of an accident, a quick response is imperative and to act efficiently, a correct knowledge of the situation as well as an accurate estimation of its severity are required. Thus, it is essential to be able to rely on the most reliable sensors possible, in particular for the 50 to 100 classified pressure transmitters. Equipment used in nuclear plants all over the world, such pressure transmitters, are implemented following one of two different types of design: - The Monobloc design where almost all the equipment or system is installed very close to the reactor, within the reactor building. - The Bibloc design where the most sensitive parts (in particular the electronics) are removed from the harsh environment present in the vicinity of the reactor to be placed outside of the reactor building. The paper will present the advantages of the Bibloc technology and will show how this technology meets the 'Post Fukushima' requirements. (authors)

  2. Estimating Parameters for the Earth-Ionosphere Waveguide Using VLF Narrowband Transmitters

    Science.gov (United States)

    Gross, N. C.; Cohen, M.

    2017-12-01

    Estimating the D-region (60 to 90 km altitude) ionospheric electron density profile has always been a challenge. The D-region's altitude is too high for aircraft and balloons to reach but is too low for satellites to orbit at. Sounding rocket measurements have been a useful tool for directly measuring the ionosphere, however, these types of measurements are infrequent and costly. A more sustainable type of measurement, for characterizing the D-region, is remote sensing with very low frequency (VLF) waves. Both the lower ionosphere and Earth's ground strongly reflect VLF waves. These two spherical reflectors form what is known as the Earth-ionosphere waveguide. As VLF waves propagate within the waveguide, they interact with the D-region ionosphere, causing amplitude and phase changes that are polarization dependent. These changes can be monitored with a spatially distributed array of receivers and D-region properties can be inferred from these measurements. Researchers have previously used VLF remote sensing techniques, from either narrowband transmitters or sferics, to estimate the density profile, but these estimations are typically during a short time frame and over a narrow propagation region. We report on an effort to improve the understanding of VLF wave propagation by estimating the commonly known h' and beta two parameter exponential electron density profile. Measurements from multiple narrowband transmitters at multiple receivers are taken, concurrently, and input into an algorithm. The cornerstone of the algorithm is an artificial neural network (ANN), where input values are the received narrowband amplitude and phase and the outputs are the estimated h' and beta parameters. Training data for the ANN is generated using the Navy's Long-Wavelength Propagation Capability (LWPC) model. Emphasis is placed on profiling the daytime ionosphere, which has a more stable and predictable profile than the nighttime. Daytime ionospheric disturbances, from high solar

  3. Influence of water vapour and permanent gases on the atmospheric optical depths and transmittance

    Science.gov (United States)

    Badescu, V.

    1991-05-01

    The influence of the atmospheric state on the extinction of direct solar radiation has been studied by using a four layer atmospheric model. Simple analytical formulae are established for the spectral optical depths of permanent gases and water vapour. These formulae use the ground level values of air pressure, temperature and relative huniidity. An additional parameter, related to the vertical distribution of the hunmidity content, is used for a better estimation of the water vapour optical depth. Good agreement between theory and measurements is found. The paper shows the dependence of the atmospheric spectral transmittance on the above mentioned parameters. L'influence de l'état atmosphérique sur l'extinction de la radiation solaire directe a été étudiée à l'aide d'un modèle atmosphérique développé antérieurement par l'auteur. Des formules simples ont été établies pour l'épaisseur optique spectrale des gaz et de la vapeur d'eau. Ces formules utilisent les valeurs de la pression atmosphérique, de la température et de l'humidité relative, mesurées au niveau du sol. Un paramètre supplémentaire, lié à la distribution verticale du contenu d'humidité, est utilisé pour calculer l'épaisseur optique due à la vapeur d'eau. La théorie est en bon accord avec les résultats des mesures. Le travail montre la dépendance de la transmittance atmosphérique spectrale en fonction des paramètres spécifiés ci-dessus.

  4. Optical design of transmitter lens for asymmetric distributed free space optical networks

    Science.gov (United States)

    Wojtanowski, Jacek; Traczyk, Maciej

    2018-05-01

    We present a method of transmitter lens design dedicated for light distribution shaping on a curved and asymmetric target. In this context, target is understood as a surface determined by hypothetical optical detectors locations. In the proposed method, ribbon-like surfaces of arbitrary shape are considered. The designed lens has the task to transform collimated and generally non-uniform input beam into desired irradiance distribution on such irregular targets. Desired irradiance is associated with space-dependant efficiency of power flow between the source and receivers distributed on the target surface. This unconventional nonimaging task is different from most illumination or beam shaping objectives, where constant or prescribed irradiance has to be produced on a flat target screen. The discussed optical challenge comes from the applications where single transmitter cooperates with multitude of receivers located in various positions in space and oriented in various directions. The proposed approach is not limited to optical networks, but can be applied in a variety of other applications where nonconventional irradiance distribution has to be engineered. The described method of lens design is based on geometrical optics, radiometry and ray mapping philosophy. Rays are processed as a vector field, each of them carrying a certain amount of power. Having the target surface shape and orientation of receivers distribution, the rays-surface crossings map is calculated. It corresponds to the output rays vector field, which is referred to the calculated input rays spatial distribution on the designed optical surface. The application of Snell's law in a vector form allows one to obtain surface local normal vector and calculate lens profile. In the paper, we also present the case study dealing with exemplary optical network. The designed freeform lens is implemented in commercially available optical design software and irradiance three-dimensional spatial distribution is

  5. The effect of imiquimod on taste bud calcium transients and transmitter secretion.

    Science.gov (United States)

    Huang, Anthony Y; Wu, Sandy Y

    2016-11-01

    Imiquimod is an immunomodulator approved for the treatment of basal cell carcinoma and has adverse side effects, including taste disturbances. Paracrine transmission, representing cell-cell communication within taste buds, has the potential to shape the final signals that taste buds transmit to the brain. Here, we tested the underlying assumption that imiquimod modifies taste transmitter secretion in taste buds of mice. Taste buds were isolated from C57BL/6J mice. The effects of imiquimod on transmitter release in taste buds were measured using calcium imaging with cellular biosensors, and examining the net effect of imiquimod on taste-evoked ATP secretion from mouse taste buds. Up to 72% of presynaptic (Type III) taste cells responded to 100 μM imiquimod with an increase in intracellular Ca 2+ concentrations. These Ca 2 + responses were inhibited by thapsigargin, an inhibitor of the sarco/endoplasmic reticulum Ca 2 + -ATPase, and by U73122, a PLC inhibitor, suggesting that the Ca 2 + mobilization elicited by imiquimod was dependent on release from internal Ca 2 + stores. Moreover, combining studies of Ca 2 + imaging with cellular biosensors showed that imiquimod evoked secretion of 5-HT, which then provided negative feedback onto receptor (Type II) cells to reduce taste-evoked ATP secretion. Our results provide evidence that there is a subset of taste cells equipped with a range of intracellular mechanisms that respond to imiquimod. The findings are also consistent with a role of imiquimod as an immune response modifier, which shapes peripheral taste responses via 5-HT signalling. © 2016 The British Pharmacological Society.

  6. Knocking out P2X receptors reduces transmitter secretion in taste buds

    Science.gov (United States)

    Huang, Yijen A.; Stone, Leslie M.; Pereira, Elizabeth; Yang, Ruibiao; Kinnamon, John C.; Dvoryanchikov, Gennady; Chaudhari, Nirupa; Finger, Thomas E.; Kinnamon, Sue C.; Roper, Stephen D.

    2011-01-01

    In response to gustatory stimulation, taste bud cells release a transmitter, ATP, that activates P2X2 and P2X3 receptors on gustatory afferent fibers. Taste behavior and gustatory neural responses are largely abolished in mice lacking P2X2 and P2X3 receptors (P2X2 and P2X3 double knockout, or “DKO” mice). The assumption has been that eliminating P2X2 and P2X3 receptors only removes postsynaptic targets but that transmitter secretion in mice is normal. Using functional imaging, ATP biosensor cells, and a cell-free assay for ATP, we tested this assumption. Surprisingly, although gustatory stimulation mobilizes Ca2+ in taste Receptor (Type II) cells from DKO mice, as from wild type (WT) mice, taste cells from DKO mice fail to release ATP when stimulated with tastants. ATP release could be elicited by depolarizing DKO Receptor cells with KCl, suggesting that ATP-release machinery remains functional in DKO taste buds. To explore the difference in ATP release across genotypes, we employed reverse transcriptase (RT)-PCR, immunostaining, and histochemistry for key proteins underlying ATP secretion and degradation: Pannexin1, TRPM5, and NTPDase2 (ecto-ATPase) are indistinguishable between WT and DKO mice. The ultrastructure of contacts between taste cells and nerve fibers is also normal in the DKO mice. Finally, quantitative RT-PCR show that P2X4 and P2X7, potential modulators of ATP secretion, are similarly expressed in taste buds in WT and DKO taste buds. Importantly, we find that P2X2 is expressed in WT taste buds and appears to function as an autocrine, positive feedback signal to amplify taste-evoked ATP secretion. PMID:21940456

  7. Influence of Finishing and Polishing Techniques and Abrasion on Transmittance and Roughness of Composite Resins.

    Science.gov (United States)

    Carneiro, Pma; Ramos, T M; de Azevedo, C S; de Lima, E; de Souza, Shj; Turbino, M L; Cesar, P F; Matos, A B

    The aim of this study was to evaluate the influence of finishing and polishing systems and toothbrush abrasion on transmittance (T) and surface roughness (Ra) of three composite resins (Filtek Z350 XT, Tetric N-Ceram, and IPS Empress Direct). Eighteen resin disks (10 mm diameter × 2 mm thick) finished by polyester strips had initial surface smoothness recorded, representing phase 1 (P1). Specimens were divided into three groups (n=6) according to the finishing/polishing instrument used (OneGloss, TopGloss, and Sof-Lex) to compose phase 2 samples (P2). Then specimens were subjected to 514 cycles of toothbrush simulation using a toothpaste slurry, with a constant load applied to soft bristles, and were then washed (phase 3=P3). After each phase, the specimens were examined by an optical profiler and spectrophotometer to measure Ra and T. Data were analyzed by analysis of variance, Tukey and Pearson tests. T values were statistically influenced by composite resin ( p=0.000) and phase of measurement ( p=0.000) factors, while the finishing/polishing system used ( p=0.741) did not affect T. On the other hand, Ra values were statistically affected by the factor finishing/polishing system ( p=0.000), but not by composite resin ( p=0.100) and phase of measurement ( p=0.451). Tetric N-Ceram and Empress Direct presented higher values of roughness when polished by OneGloss, while TopGloss and Sof-Lex showed a lower roughness. It can be concluded that composite resins transmitted more light after dental abrasion. Transmittance of composite resins was not modified by the distinct roughness created by finishing/polishing instruments.

  8. The effect of imiquimod on taste bud calcium transients and transmitter secretion

    Science.gov (United States)

    Wu, Sandy Y

    2016-01-01

    Background and Purpose Imiquimod is an immunomodulator approved for the treatment of basal cell carcinoma and has adverse side effects, including taste disturbances. Paracrine transmission, representing cell–cell communication within taste buds, has the potential to shape the final signals that taste buds transmit to the brain. Here, we tested the underlying assumption that imiquimod modifies taste transmitter secretion in taste buds of mice. Experimental Approach Taste buds were isolated from C57BL/6J mice. The effects of imiquimod on transmitter release in taste buds were measured using calcium imaging with cellular biosensors, and examining the net effect of imiquimod on taste‐evoked ATP secretion from mouse taste buds. Key Results Up to 72% of presynaptic (Type III) taste cells responded to 100 μM imiquimod with an increase in intracellular Ca2+ concentrations. These Ca2 + responses were inhibited by thapsigargin, an inhibitor of the sarco/endoplasmic reticulum Ca2 +‐ATPase, and by U73122, a PLC inhibitor, suggesting that the Ca2 + mobilization elicited by imiquimod was dependent on release from internal Ca2 + stores. Moreover, combining studies of Ca2 + imaging with cellular biosensors showed that imiquimod evoked secretion of 5‐HT, which then provided negative feedback onto receptor (Type II) cells to reduce taste‐evoked ATP secretion. Conclusion and Implications Our results provide evidence that there is a subset of taste cells equipped with a range of intracellular mechanisms that respond to imiquimod. The findings are also consistent with a role of imiquimod as an immune response modifier, which shapes peripheral taste responses via 5‐HT signalling. PMID:27464850

  9. Knocking out P2X receptors reduces transmitter secretion in taste buds.

    Science.gov (United States)

    Huang, Yijen A; Stone, Leslie M; Pereira, Elizabeth; Yang, Ruibiao; Kinnamon, John C; Dvoryanchikov, Gennady; Chaudhari, Nirupa; Finger, Thomas E; Kinnamon, Sue C; Roper, Stephen D

    2011-09-21

    In response to gustatory stimulation, taste bud cells release a transmitter, ATP, that activates P2X2 and P2X3 receptors on gustatory afferent fibers. Taste behavior and gustatory neural responses are largely abolished in mice lacking P2X2 and P2X3 receptors [P2X2 and P2X3 double knock-out (DKO) mice]. The assumption has been that eliminating P2X2 and P2X3 receptors only removes postsynaptic targets but that transmitter secretion in mice is normal. Using functional imaging, ATP biosensor cells, and a cell-free assay for ATP, we tested this assumption. Surprisingly, although gustatory stimulation mobilizes Ca(2+) in taste Receptor (Type II) cells from DKO mice, as from wild-type (WT) mice, taste cells from DKO mice fail to release ATP when stimulated with tastants. ATP release could be elicited by depolarizing DKO Receptor cells with KCl, suggesting that ATP-release machinery remains functional in DKO taste buds. To explore the difference in ATP release across genotypes, we used reverse transcriptase (RT)-PCR, immunostaining, and histochemistry for key proteins underlying ATP secretion and degradation: Pannexin1, TRPM5, and NTPDase2 (ecto-ATPase) are indistinguishable between WT and DKO mice. The ultrastructure of contacts between taste cells and nerve fibers is also normal in the DKO mice. Finally, quantitative RT-PCR show that P2X4 and P2X7, potential modulators of ATP secretion, are similarly expressed in taste buds in WT and DKO taste buds. Importantly, we find that P2X2 is expressed in WT taste buds and appears to function as an autocrine, positive feedback signal to amplify taste-evoked ATP secretion.

  10. Surgical management of stress urinary incontinence in women: safety, effectiveness and cost-utility of trans-obturator tape (TOT versus tension-free vaginal tape (TVT five years after a randomized surgical trial

    Directory of Open Access Journals (Sweden)

    Eliasziw Misha

    2011-07-01

    Full Text Available Abstract Background We recently completed a randomized clinical trial of two minimally invasive surgical procedures for stress urinary incontinence, the retropubic tension-free vaginal tape (TVT versus the trans-obturator tape (TOT procedure. At one year postoperatively, we were concerned to find that a significant number of women had tape that was palpable when a vaginal examination was undertaken. Because the risk factors for adverse outcomes of tape surgery are not clearly understood, we are unable to say whether palpable tapes will lead to vaginal erosions or whether they merge into vaginal tissue. We do not know whether patients go on to have further adverse consequences of surgery, leading to additional cost to patients and healthcare system. Our current study is a 5 year follow-up of the women who took part in our original trial. Methods/Design All 199 women who participated in our original trial will be contacted and invited to take part in the follow-up study. Consenting women will attend a clinic visit where they will have a physical examination to identify vaginal erosion or other serious adverse outcomes of surgery, undertake a standardized pad test for urinary incontinence, and complete several health-related quality of life questionnaires (15D, UDI-6, IIQ-7. Analyses will compare the outcomes for women in the TOT versus TVT groups. The cost-effectiveness of TOT versus TVT over the 5 years after surgery, will be assessed with the use of disease-specific health service administrative data and an objective health outcome measure. A cost-utility analysis may also be undertaken, based on economic modeling, data from the clinical trial and inputs obtained from published literature. Discussion This study is needed now, because TOT and TVT are among the most frequently conducted surgical procedures for stress urinary incontinence in Canada. Because stress urinary incontinence is so common, the impact of selecting an approach that causes

  11. Surgical management of stress urinary incontinence in women: safety, effectiveness and cost-utility of trans-obturator tape (TOT) versus tension-free vaginal tape (TVT) five years after a randomized surgical trial

    Science.gov (United States)

    2011-01-01

    Background We recently completed a randomized clinical trial of two minimally invasive surgical procedures for stress urinary incontinence, the retropubic tension-free vaginal tape (TVT) versus the trans-obturator tape (TOT) procedure. At one year postoperatively, we were concerned to find that a significant number of women had tape that was palpable when a vaginal examination was undertaken. Because the risk factors for adverse outcomes of tape surgery are not clearly understood, we are unable to say whether palpable tapes will lead to vaginal erosions or whether they merge into vaginal tissue. We do not know whether patients go on to have further adverse consequences of surgery, leading to additional cost to patients and healthcare system. Our current study is a 5 year follow-up of the women who took part in our original trial. Methods/Design All 199 women who participated in our original trial will be contacted and invited to take part in the follow-up study. Consenting women will attend a clinic visit where they will have a physical examination to identify vaginal erosion or other serious adverse outcomes of surgery, undertake a standardized pad test for urinary incontinence, and complete several health-related quality of life questionnaires (15D, UDI-6, IIQ-7). Analyses will compare the outcomes for women in the TOT versus TVT groups. The cost-effectiveness of TOT versus TVT over the 5 years after surgery, will be assessed with the use of disease-specific health service administrative data and an objective health outcome measure. A cost-utility analysis may also be undertaken, based on economic modeling, data from the clinical trial and inputs obtained from published literature. Discussion This study is needed now, because TOT and TVT are among the most frequently conducted surgical procedures for stress urinary incontinence in Canada. Because stress urinary incontinence is so common, the impact of selecting an approach that causes more adverse events, or is

  12. Inter-comparison of NIOSH and IMPROVE protocols for OC and EC determination: implications for inter-protocol data conversion

    Science.gov (United States)

    Wu, Cheng; Huang, X. H. Hilda; Ng, Wai Man; Griffith, Stephen M.; Zhen Yu, Jian

    2016-09-01

    Organic carbon (OC) and elemental carbon (EC) are operationally defined by analytical methods. As a result, OC and EC measurements are protocol dependent, leading to uncertainties in their quantification. In this study, more than 1300 Hong Kong samples were analyzed using both National Institute for Occupational Safety and Health (NIOSH) thermal optical transmittance (TOT) and Interagency Monitoring of Protected Visual Environment (IMPROVE) thermal optical reflectance (TOR) protocols to explore the cause of EC disagreement between the two protocols. EC discrepancy mainly (83 %) arises from a difference in peak inert mode temperature, which determines the allocation of OC4NSH, while the rest (17 %) is attributed to a difference in the optical method (transmittance vs. reflectance) applied for the charring correction. Evidence shows that the magnitude of the EC discrepancy is positively correlated with the intensity of the biomass burning signal, whereby biomass burning increases the fraction of OC4NSH and widens the disagreement in the inter-protocol EC determination. It is also found that the EC discrepancy is positively correlated with the abundance of metal oxide in the samples. Two approaches (M1 and M2) that translate NIOSH TOT OC and EC data into IMPROVE TOR OC and EC data are proposed. M1 uses direct relationship between ECNSH_TOT and ECIMP_TOR for reconstruction: M1 : ECIMP_TOR = a × ECNSH_TOT + b; while M2 deconstructs ECIMP_TOR into several terms based on analysis principles and applies regression only on the unknown terms: M2 : ECIMP_TOR = AECNSH + OC4NSH - (a × PCNSH_TOR + b), where AECNSH, apparent EC by the NIOSH protocol, is the carbon that evolves in the He-O2 analysis stage, OC4NSH is the carbon that evolves at the fourth temperature step of the pure helium analysis stage of NIOSH, and PCNSH_TOR is the pyrolyzed carbon as determined by the NIOSH protocol. The implementation of M1 to all urban site data (without considering seasonal specificity

  13. Effect of package light transmittance on the vitamin content of milk, part 3: Fortified UHT low-fat milk

    NARCIS (Netherlands)

    Saffert, A.; Pieper, G.; Jetten, J.

    2009-01-01

    This work is the third and last part of a milk study evaluating the effect of package light transmittance on the vitamin content of milk, in this case on fortified UHT low-fat milk. The milk was stored under light with an intensity of 700 lux in polyethylene terephthalate (PET) bottles with varying

  14. A New Metre for Cheap, Quick, Reliable and Simple Thermal Transmittance (U-Value) Measurements in Buildings.

    Science.gov (United States)

    Andújar Márquez, José Manuel; Martínez Bohórquez, Miguel Ángel; Gómez Melgar, Sergio

    2017-09-03

    This paper deals with the thermal transmittance measurement focused on buildings and specifically in building energy retrofitting. Today, if many thermal transmittance measurements in a short time are needed, the current devices, based on the measurement of the heat flow through the wall, cannot carry out them, except if a great amount of devices are used at once along with intensive and tedious post-processing and analysis work. In this paper, from well-known physical laws, authors develop a methodology based on three temperatures measurements, which is implemented by a novel thermal transmittance metre. The paper shows its development step by step. As a result the developed device is modular, scalable, and fully wireless; it is capable of taking as many measurements at once as user needs. The developed system is compared working together on a same test to the currently used one based on heat flow. The results show that the developed metre allows carrying out thermal transmittance measurements in buildings in a cheap, quick, reliable and simple way.

  15. Accurate expressions for the power efficiency of a class-D power amplifier in a limit-cycle transmitter configuration

    NARCIS (Netherlands)

    Sarkeshi, M.; Mahmoudi, R.; Roermund, van A.H.M.

    2009-01-01

    Limit-cycle based, self-oscillating amplifiers are promising candidates for linear amplification of complex signals with high peak-to-average ratio, while maintaining high power efficiency. Limit-cycle transmitters employ switch class-D power amplifiers in order to achieve high Efficiency. In this

  16. Fibre optic spectrophotometry for the in vitro evaluation of ultraviolet radiation (UVR) spectral transmittance of rabbit corneas

    International Nuclear Information System (INIS)

    Walsh, J E; Fleming, D P; Bergmanson, J P G; Koehler, L V; Doughty, M J; Harmey, J H

    2008-01-01

    A fibre optic spectrophotometer front-end system for measuring corneas to overcome shortcomings associated with existing instruments was tested. The system allowed prompt measurement postmortem, minimizing beam pathlength to reduce the effects of scatter and unwanted refraction and eliminated optical interfaces and cuvette media. Rabbit corneas were excised immediately postmortem and placed on a detecting fibre optic coupled to an Ocean Optics spectrophotometer and illuminated by a deuterium–halogen source. The compact instrument with its small beam size allowed tissue profiling at test points across the corneal surface and efficient interchange for comparison of different tissues. This simplified system operation allowed rapid tissue altering to study induced changes on transmittance. The corneal transmittance data showed a consistent sharp cut-off at 320 nm in the ultraviolet radiation (UVR) spectrum, which decayed rapidly from postmortem swelling. Inter- and intra-corneal consistency was demonstrated by comparing data from different regions of the same cornea and those from opposite eyes. Changes to the spectra, particularly in the UVB below 300 nm, were evident when the corneal epithelium was removed, indicating that this layer is not the only corneal UVR filter. The new system reduced much of the variability associated with previous methods, as it rapidly measured corneal transmittance postmortem. Data are in broad agreement with published transmittance curves. The removal of the corneal epithelium revealed a substantial stromal contribution to the overall corneal UVR absorption, suggesting that corneas with pathologically or iatrogenically thinned stromas are less effective UVR blockers

  17. A 16.3 pJ/pulse low-complexity and energy-efficient transmitter with adjustable pulse parameters

    International Nuclear Information System (INIS)

    Jiang Jun; Zhao Yi; Shao Ke; Chen Hu; Xia Lingli; Hong Zhiliang

    2011-01-01

    This paper presents a novel, fully integrated transmitter for 3-5 GHz pulsed UWB. The BPSK modulation transmitter has been implemented in SMIC CMOS 0.13 μm technology with a 1.2-V supply voltage and a die size of 0.8 x 0.95 mm 2 . This transmitter is based on the impulse response filter method, which uses a tunable R paralleled with a LC frequency selection network to realize continuously adjustable pulse parameters, including bandwidth, width and amplitude. Due to the extremely low duty of the pulsed UWB, a proposed output buffer is employed to save power consumption significantly. Finally, measurement results show that the transmitter consumes only 16.3 pJ/pulse to achieve a pulse repetition rate of 100 Mb/s. Generated pulses strictly comply with the FCC spectral mask. The continuously variable pulse width is from 900 to 1.5 ns and the amplitude with the minimum 178 mVpp and the maximum 432 mVpp can be achieved. (semiconductor integrated circuits)

  18. All-optical OFDM system using a wavelength selective switch based transmitter and a spectral magnification based receiver

    DEFF Research Database (Denmark)

    Guan, Pengyu; Lefrancois, S.; Lillieholm, Mads

    2014-01-01

    We demonstrate an AO-OFDM system with a WSS-based transmitter and time-lens based receiver for spectral magnification, achieving BER~10-9 for a 28×10 Gbit/s DPSK AO-OFDM signal. Furthermore, the receiver performance for DPSK and DQPSK is investigated using Monte Carlo simulations....

  19. Electric-field induced surface instabilities of soft dielectrics and their effects on optical transmittance and scattering

    Science.gov (United States)

    Shian, Samuel; Kjeer, Peter; Clarke, David R.

    2018-03-01

    When a voltage is applied to a percolative, mechanically compliant mat of carbon nanotubes (CNTs) on a smooth elastomer bilayer attached to an ITO coated glass substrate, the in-line optical transmittance decreases with increasing voltage. Two regimes of behavior have been identified based on optical scattering, bright field optical microscopy, and confocal optical microscopy. In the low field regime, the electric field produces a spatially inhomogeneous surface deformation of the elastomer that causes local variations in optical refraction and modulates the light transmittance. The spatial variation is associated with the distribution of the CNTs over the surface. At higher fields, above a threshold voltage, an array of pits in the surface form by a nucleation and growth mechanism and these also scatter light. The formation of pits, and creases, in the thickness of the elastomer, is due to a previously identified electro-mechanical surface instability. When the applied voltage is decreased from its maximum, the transmittance returns to its original value although there is a transmittance hysteresis and a complicated time response. When the applied voltage exceeds the threshold voltage, there can be remnant optical contrast associated with creasing of the elastomer and the recovery time appears to be dependent on local jamming of CNTs in areas where the pits formed. A potential application of this work as an electrically tunable privacy window or camouflaging devices is demonstrated.

  20. Bistable near field and bistable transmittance in 2D composite slab consisting of nonlocal core-Kerr shell inclusions.

    Science.gov (United States)

    Huang, Yang; Wu, Ya Min; Gao, Lei

    2017-01-23

    We carry out a theoretical study on optical bistability of near field intensity and transmittance in two-dimensional nonlinear composite slab. This kind of 2D composite is composed of nonlocal metal/Kerr-type dielectric core-shell inclusions randomly embedded in the host medium, and we derivate the nonlinear relation between the field intensity in the shell of inclusions and the incident field intensity with self-consistent mean field approximation. Numerical demonstration has been performed to show the viable parameter space for the bistable near field. We show that nonlocality can provide broader region in geometric parameter space for bistable near field as well as bistable transmittance of the nonlocal composite slab compared to local case. Furthermore, we investigate the bistable transmittance in wavelength spectrum, and find that besides the input intensity, the wavelength operation could as well make the transmittance jump from a high value to a low one. This kind of self-tunable nano-composite slab might have potential application in optical switching devices.

  1. Direct-Digital Modulation (DIDIMO) Transmitter with -156dBc/Hz Rx-Band Noise using FIR structure

    NARCIS (Netherlands)

    Fukuda, Shuichi; Miya, Shinji; Io, Miho; Hamashita, Koichi; Nauta, Bram

    2012-01-01

    A direct-digital modulation (DIDIMO) transmitter employing 3-taps 10-bit Finite Impulse Response configuration is proposed and evaluated. FIR-DIDIMO provides simultaneous combination of D/A conversion, up-conversion, power control and also quantization noise filtering at arbitrary offset frequency

  2. Design of band-pass push-pull stages of power amplifiers for UHF transmitters of FM and TV broadcasting

    OpenAIRE

    Titov, A. A.

    2005-01-01

    The paper considers principles of construction, peculiarities of design, and techniques of network element calculation of push-pull amplification stages in linear bipolar microwave transistors. An example of calculation and results of experimental tests of an amplifier for transmitters of FM and TV broadcasting are presented.

  3. Design of an adaptive CubeSat transmitter for achieving optimum signal-to-noise ratio (SNR)

    Science.gov (United States)

    Jaswar, F. D.; Rahman, T. A.; Hindia, M. N.; Ahmad, Y. A.

    2017-12-01

    CubeSat technology has opened the opportunity to conduct space-related researches at a relatively low cost. Typical approach to maintain an affordable cubeSat mission is to use a simple communication system, which is based on UHF link with fixed-transmit power and data rate. However, CubeSat in the Low Earth Orbit (LEO) does not have relative motion with the earth rotation, resulting in variable propagation path length that affects the transmission signal. A transmitter with adaptive capability to select multiple sets of data rate and radio frequency (RF) transmit power is proposed to improve and optimise the link. This paper presents the adaptive UHF transmitter design as a solution to overcome the variability of the propagation path. The transmitter output power is adjustable from 0.5W to 2W according to the mode of operations and satellite power limitations. The transmitter is designed to have four selectable modes to achieve the optimum signal-to-noise ratio (SNR) and efficient power consumption based on the link budget analysis and satellite requirement. Three prototypes are developed and tested for space-environment conditions such as the radiation test. The Total Ionizing Dose measurements are conducted in the radiation test done at Malaysia Nuclear Agency Laboratory. The results from this test have proven that the adaptive transmitter can perform its operation with estimated more than seven months in orbit. This radiation test using gamma source with 1.5krad exposure is the first one conducted for a satellite program in Malaysia.

  4. Comparison of Electron Transmittance and Tunneling Current through a Trapezoidal Potential Barrier with Spin Polarization Consideration by using Analytical and Numerical Approaches

    Science.gov (United States)

    Nabila, Ezra; Noor, Fatimah A.; Khairurrijal

    2017-07-01

    In this study, we report an analytical calculation of electron transmittance and polarized tunneling current in a single barrier heterostructure of a metal-GaSb-metal by considering the Dresselhaus spin orbit effect. Exponential function, WKB method and Airy function were used in calculating the electron transmittance and tunneling current. A Transfer Matrix Method, as a numerical method, was utilized as the benchmark to evaluate the analytical calculation. It was found that the transmittances calculated under exponential function and Airy function is the same as that calculated under TMM method at low electron energy. However, at high electron energy only the transmittance calculated under Airy function approach is the same as that calculated under TMM method. It was also shown that the transmittances both of spin-up and spin-down conditions increase as the electron energy increases for low energies. Furthermore, the tunneling current decreases with increasing the barrier width.

  5. [On-site evaluation of raw milk qualities by portable Vis/NIR transmittance technique].

    Science.gov (United States)

    Wang, Jia-Hua; Zhang, Xiao-Wei; Wang, Jun; Han, Dong-Hai

    2014-10-01

    To ensure the material safety of dairy products, visible (Vis)/near infrared (NIR) spectroscopy combined with che- mometrics methods was used to develop models for fat, protein, dry matter (DM) and lactose on-site evaluation. A total of 88 raw milk samples were collected from individual livestocks in different years. The spectral of raw milk were measured by a porta- ble Vis/NIR spectrometer with diffused transmittance accessory. To remove the scatter effect and baseline drift, the diffused transmittance spectra were preprocessed by 2nd order derivative with Savitsky-Golay (polynomial order 2, data point 25). Changeable size moving window partial least squares (CSMWPLS) and genetic algorithms partial least squares (GAPLS) meth- ods were suggested to select informative regions for PLS calibration. The PLS and multiple linear regression (MLR) methods were used to develop models for predicting quality index of raw milk. The prediction performance of CSMWPLS models were similar to GAPLS models for fat, protein, DM and lactose evaluation, the root mean standard errors of prediction (RMSEP) were 0.115 6/0.103 3, 0.096 2/0.113 7, 0.201 3/0.123 7 and 0.077 4/0.066 8, and the relative standard deviations of prediction (RPD) were 8.99/10.06, 3.53/2.99, 5.76/9.38 and 1.81/2.10, respectively. Meanwhile, the MLR models were also cal- ibrated with 8, 10, 9 and 7 variables for fat, protein, DM and lactose, respectively. The prediction performance of MLR models was better than or close to PLS models. The MLR models to predict fat, protein, DM and lactose yielded the RMSEP of 0.107 0, 0.093 0, 0.136 0 and 0.065 8, and the RPD of 9.72, 3.66, 8.53 and 2.13, respectively. The results demonstrated the usefulness of Vis/NIR spectra combined with multivariate calibration methods as an objective and rapid method for the quality evaluation of complicated raw milks. And the results obtained also highlight the potential of portable Vis/NIR instruments for on-site assessing quality indexes of

  6. The Efficacy of Ultraviolet Radiation for Sterilizing Tools Used for Surgically Implanting Transmitters into Fish

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Ricardo W.; Markillie, Lye Meng; Colotelo, Alison HA; Gay, Marybeth E.; Woodley, Christa M.; Brown, Richard S.

    2013-02-28

    Telemetry is frequently used to examine the behavior of fish, and the transmitters used are normally surgically implanted into the coelom of fish. Implantation requires the use of surgical tools such as scalpels, forceps, needle holders, and sutures. When several fish are implanted consecutively for large telemetry studies, it is common for surgical tools to be sterilized or, at minimum, disinfected between each use so that pathogens that may be present are not spread among fish. However, autoclaving tools can take a long period of time, and chemical sterilants or disinfectants can be harmful to both humans and fish and have varied effectiveness. Ultraviolet (UV) radiation is commonly used to disinfect water in aquaculture facilities. However, this technology has not been widely used to sterilize tools for surgical implantation of transmitters in fish. To determine its efficacy for this application, Pacific Northwest National Laboratory researchers used UV radiation to disinfect surgical tools (i.e., forceps, needle holder, stab scalpel, and suture) that were exposed to one of four aquatic organisms that typically lead to negative health issues for salmonids. These organisms included Aeromonas salmonicida, Flavobacterium psychrophilum, Renibacterium salmoninarum, and Saprolegnia parasitica. Surgical tools were exposed to the bacteria by dipping them into a confluent suspension of three varying concentrations (i.e., low, medium, high). After exposure to the bacterial culture, tools were placed into a mobile Millipore UV sterilization apparatus. The tools were then exposed for three different time periods—2, 5, or 15 min. S. parasitica, a water mold, was tested using an agar plate method and forceps-pinch method. UV light exposures of 5 and 15 min were effective at killing all four organisms. UV light was also effective at killing Geobacillus stearothermophilus, the organism used as a biological indicator to verify effectiveness of steam sterilizers. These

  7. How Low Can You Go? Determining a Size Threshold for Implantation of a New Acoustic Transmitter in Age-0 White Sturgeon

    Energy Technology Data Exchange (ETDEWEB)

    Ashton, Neil K.; Liss, Stephanie A.; Walker, Ricardo W.; Brown, Richard S.; Klassen, Cheryl; Backhouse, Stephanie; Bates, Phil; Townsend, Richard L.

    2017-01-01

    Telemetry studies are often used to investigate sturgeon habitat use and movement patterns; however, existing acoustic transmitters are generally too large to implant into age-0 sturgeon without harming the fish. Recent development of a miniaturized acoustic transmitter (cylindrical, 0.7 g in air, 24.2 mm long, 5.0 mm diameter) with up to 365 d battery life has the potential to advance our understanding of age-0 sturgeon ecology in rivers and lakes. Prior to use in field studies, it is essential to conduct experiments evaluating potential adverse transmitter effects on fish. We tested transmitter retention, fish survival, and growth of a broad size range of age-0 white sturgeon (Acipenser transmontanus; 158–277 mm fork length; 26–126 g; 0.6–2.6% transmitter burden) in an 84 d laboratory study, with an ultimate goal of determining a minimum size threshold of sturgeon that can be implanted with this acoustic transmitter. At 84 d post-implantation, transmitter retention and fish survival were 100%. Specific growth rates were reduced at 7 and 14 d post-implantation, resulting in minimum fork length thresholds of 250 and 171 mm, respectively. Juveniles implanted with transmitters regained their growth potential by 28 d post-implantation and no size differences were detected in comparisons with unmarked control fish. This study demonstrates the ability to implant small age-0 sturgeon with high transmitter retention and fish survival, and only minor growth effects. Use of new miniaturized acoustic transmitters may give researchers a means to address questions about young-of-the-year fish recruitment, ecological patterns, and potentially advance conservation management of sturgeon populations.

  8. Field Emission Property of Double-walled Carbon Nanotubes Related to Purification and Transmittance

    International Nuclear Information System (INIS)

    Ahn, KiTae; Jang, HyunChul; Hong, Wanshick; Park, Kyoungwan; Sok, Junghyun; Lyu, SeungChul; Lee, Hansung; Lee, Naesung; Han, Moonsup; Park, Yunsun

    2011-01-01

    Double-walled carbon nanotubes (DWCNTs) with high purity were produced by the catalytic decomposition of tetrahydrofuran (THF) using a Fe-Mo/MgO catalyst at 800°C. The as-synthesized DWCNTs typically have catalytic impurities and amorphous carbon, which were removed by a two-step purification process consisting of acid treatment and oxidation. In the acid treatment, metallic catalysts were removed in HCl at room temperature for 5 hr with magnetic stirring. Subsequently, the oxidation, using air at 380°C for 5 hr in the a vertical-type furnace, was used to remove the amorphous carbon particles. The DWCNT suspension was prepared by dispersing the purified DWCNTs in the aqueous sodium dodecyl sulfate solution with horn-type sonication. This was then air-sprayed on ITO glass to fabricate DWCNT field emitters. The field emission properties of DWCNT films related to transmittance were studied. This study provides the possibility of the application of large-area transparent CNT field emission cathodes.

  9. Developing high-transmittance heterojunction diodes based on NiO/TZO bilayer thin films

    Science.gov (United States)

    2013-01-01

    In this study, radio frequency magnetron sputtering was used to deposit nickel oxide thin films (NiO, deposition power of 100 W) and titanium-doped zinc oxide thin films (TZO, varying deposition powers) on glass substrates to form p(NiO)-n(TZO) heterojunction diodes with high transmittance. The structural, optical, and electrical properties of the TZO and NiO thin films and NiO/TZO heterojunction devices were investigated with scanning electron microscopy, X-ray diffraction (XRD) patterns, UV-visible spectroscopy, Hall effect analysis, and current-voltage (I-V) analysis. XRD analysis showed that only the (111) diffraction peak of NiO and the (002) and (004) diffraction peaks of TZO were observable in the NiO/TZO heterojunction devices, indicating that the TZO thin films showed a good c-axis orientation perpendicular to the glass substrates. When the sputtering deposition power for the TZO thin films was 100, 125, and 150 W, the I-V characteristics confirmed that a p-n junction characteristic was successfully formed in the NiO/TZO heterojunction devices. We show that the NiO/TZO heterojunction diode was dominated by the space-charge limited current theory. PMID:23634999

  10. Atmospheric turbidity and transmittance of solar radiation in Riyadh, Saudi Arabia

    Science.gov (United States)

    El-Shobokshy, Mohammad S.; Al-Saedi, Yaseen G.

    During the last two decades, the urban areas in the city of Riyadh—the capital of Saudi Arabia—were increasing at an exceptionally high rate through a series of development plans. The major plans had been completed by the end of 1982. Some other big utility projects were started and completed during 1987. As a consequence, the air quality has deteriorated markedly and air pollution episodes recorded during these activities showed that particulates were present in the atmosphere at high concentrations. Later in January 1991 the Gulf war started and the firing of the oil fields in Kuwait soon followed. It was estimated that soot particulates were emitted at a rate of 600 ton d -1 along with high rates of other gases. This event has led to significant air quality and visibility problems. Direct normal solar radiation has been measured during the summer months of July and August which were characterized by very dry and cloudless weather for the period between 1982 and 1992. A year-to-year trend of the transmittance of direct normal solar irradiance was then determined. The atmospheric fine aerosol (oil field fires in Kuwait were passing over Riyadh are presented. The reduction in solar irradiation reflects the intensity of dark smoke at a distance of 500 km from Kuwait.

  11. Resonator design and performance estimation for a space-based laser transmitter

    Science.gov (United States)

    Agrawal, Lalita; Bhardwaj, Atul; Pal, Suranjan; Kamalakar, J. A.

    2006-12-01

    Development of a laser transmitter for space applications is a highly challenging task. The laser must be rugged, reliable, lightweight, compact and energy efficient. Most of these features are inherently achieved by diode pumping of solid state lasers. Overall system reliability can further be improved by appropriate optical design of the laser resonator besides selection of suitable electro-optical and opto-mechanical components. This paper presents the design details and the theoretically estimated performance of a crossed-porro prism based, folded Z-shaped laser resonator. A symmetrically pumped Nd: YAG laser rod of 3 mm diameter and 60 mm length is placed in the gain arm with total input peak power of 1800 W from laser diode arrays. Electro-optical Q-switching is achieved through a combination of a polarizer, a fractional waveplate and LiNbO 3 Q-switch crystal (9 x 9 x 25 mm) placed in the feedback arm. Polarization coupled output is obtained by optimizing azimuth angle of quarter wave plate placed in the gain arm. Theoretical estimation of laser output energy and pulse width has been carried out by varying input power levels and resonator length to analyse the performance tolerances. The designed system is capable of meeting the objective of generating laser pulses of 10 ns duration and 30 mJ energy @ 10 Hz.

  12. Radio-transmitters do not affect seasonal productivity of female Golden-winged Warblers

    Science.gov (United States)

    Streby, Henry M.; Peterson, Sean M.; Gesmundo, Callie; Johnson, Michael K.; Fish, Alexander C.; Lehman, Justin A.; Andersen, David E.

    2013-01-01

    Investigating the potential effects of handling and marking techniques on study animals is important for correct interpretation of research results and to effect progress in data-collection methods. Few investigators have compared the reproductive output of radio-tagged and non-radio-tagged songbirds, and no one to date has examined the possible effect of radio-tagging adult songbirds on the survival of their fledglings. In 2011 and 2012, we compared several parameters of reproductive output of two groups of female Golden-winged Warblers (Vermivora chrysoptera) breeding in Minnesota, including 45 females with radio-transmitters and 73 females we did not capture, handle, or mark. We found no difference between groups in clutch sizes, hatching success, brood sizes, length of incubation and nestling stages, fledging success, number of fledglings, or survival of fledglings to independence. Thus, radio-tags had no measurable impact on the productivity of female Golden-winged Warblers. Our results build upon previous studies where investigators have reported no effects of radio-tagging on the breeding parameters of songbirds by also demonstrating no effect of radio-tagging through the post-fledging period and, therefore, the entire breeding season.

  13. Digital simulation of staining in histopathology multispectral images: enhancement and linear transformation of spectral transmittance.

    Science.gov (United States)

    Bautista, Pinky A; Yagi, Yukako

    2012-05-01

    Hematoxylin and eosin (H&E) stain is currently the most popular for routine histopathology staining. Special and/or immuno-histochemical (IHC) staining is often requested to further corroborate the initial diagnosis on H&E stained tissue sections. Digital simulation of staining (or digital staining) can be a very valuable tool to produce the desired stained images from the H&E stained tissue sections instantaneously. We present an approach to digital staining of histopathology multispectral images by combining the effects of spectral enhancement and spectral transformation. Spectral enhancement is accomplished by shifting the N-band original spectrum of the multispectral pixel with the weighted difference between the pixel's original and estimated spectrum; the spectrum is estimated using M transformed to the spectral configuration associated to its reaction to a specific stain by utilizing an N × N transformation matrix, which is derived through application of least mean squares method to the enhanced and target spectral transmittance samples of the different tissue components found in the image. Results of our experiments on the digital conversion of an H&E stained multispectral image to its Masson's trichrome stained equivalent show the viability of the method.

  14. Gas spectroscopy system with 245 GHz transmitter and receiver in SiGe BiCMOS

    Science.gov (United States)

    Schmalz, Klaus; Rothbart, Nick; Borngräber, Johannes; Yilmaz, Selahattin Berk; Kissinger, Dietmar; Hübers, Heinz-Wilhelm

    2017-02-01

    The implementation of an integrated mm-wave transmitter (TX) and receiver (RX) in SiGe BiCMOS or CMOS technology offers a path towards a compact and low-cost system for gas spectroscopy. Previously, we have demonstrated TXs and RXs for spectroscopy at 238 -252 GHz and 495 - 497 GHz using external phase-locked loops (PLLs) with signal generators for the reference frequency ramps. Here, we present a more compact system by using two external fractional-N PLLs allowing frequency ramps for the TX and RX, and for TX with superimposed frequency shift keying (FSK) or reference frequency modulation realized by a direct digital synthesizer (DDS) or an arbitrary waveform generator. The 1.9 m folded gas absorption cell, the vacuum pumps, as well as the TX and RX are placed on a portable breadboard with dimensions of 75 cm x 45 cm. The system performance is evaluated by high-resolution absorption spectra of gaseous methanol at 13 Pa for 241 - 242 GHz. The 2f (second harmonic) content of the absorption spectrum of the methanol was obtained by detecting the IF power of RX using a diode power sensor connected to a lock-in amplifier. The reference frequency modulation reveals a higher SNR (signal-noise-ratio) of 98 within 32 s acquisition compared to 66 for FSK. The setup allows for jumping to preselected frequency regions according to the spectral signature thus reducing the acquisition time by up to one order of magnitude.

  15. Bayesian analysis of the kinetics of quantal transmitter secretion at the neuromuscular junction.

    Science.gov (United States)

    Saveliev, Anatoly; Khuzakhmetova, Venera; Samigullin, Dmitry; Skorinkin, Andrey; Kovyazina, Irina; Nikolsky, Eugeny; Bukharaeva, Ellya

    2015-10-01

    The timing of transmitter release from nerve endings is considered nowadays as one of the factors determining the plasticity and efficacy of synaptic transmission. In the neuromuscular junction, the moments of release of individual acetylcholine quanta are related to the synaptic delays of uniquantal endplate currents recorded under conditions of lowered extracellular calcium. Using Bayesian modelling, we performed a statistical analysis of synaptic delays in mouse neuromuscular junction with different patterns of rhythmic nerve stimulation and when the entry of calcium ions into the nerve terminal was modified. We have obtained a statistical model of the release timing which is represented as the summation of two independent statistical distributions. The first of these is the exponentially modified Gaussian distribution. The mixture of normal and exponential components in this distribution can be interpreted as a two-stage mechanism of early and late periods of phasic synchronous secretion. The parameters of this distribution depend on both the stimulation frequency of the motor nerve and the calcium ions' entry conditions. The second distribution was modelled as quasi-uniform, with parameters independent of nerve stimulation frequency and calcium entry. Two different probability density functions for the distribution of synaptic delays suggest at least two independent processes controlling the time course of secretion, one of them potentially involving two stages. The relative contribution of these processes to the total number of mediator quanta released depends differently on the motor nerve stimulation pattern and on calcium ion entry into nerve endings.

  16. A Trial Intercomparison of Humidity Generators at Extremes of Range Using Relative Humidity Transmitters

    Science.gov (United States)

    Stevens, M.; Benyon, R.; Bell, S. A.; Vicente, T.

    2008-10-01

    In order to effectively implement the Mutual Recognition Arrangement (MRA) of the International Committee for Weights and Measures (CIPM), national metrology institutes (NMIs) are required to support their claims of calibration and measurement capability (CMC) with a quality system compliant with ISO/IEC 17025, and with suitable evidence of participation in key or supplementary comparisons. The CMC review process, both at regional and inter-regional levels, uses criteria that combine the provisions mentioned above, together with additional evidence demonstrating scientific and technical competence of the institutes. For dew-point temperatures, there are key comparisons in progress under the Consultative Committee for Thermometry (CCT) and under the European regional metrology organisation (EUROMET), together with information available on past regional supplementary comparisons. However, for relative humidity there are, to date, no such comparisons available to support CMC entries. This paper presents and discusses the results of a preliminary investigation of the use of relative humidity and temperature transmitters in order to determine their suitability for the intercomparison of standard humidity generators in support of CMC claims for the calibration of relative humidity instruments. The results of a recent bilateral comparison between 2 NMIs at the extremes of the range up to 98%rh at 70 °C, and down to 1%rh at -40 °C are reported. Specific precautions and recommendations on the use of the devices as transfer standards are presented.

  17. Transmitter modulation of spike-evoked calcium transients in arousal related neurons

    DEFF Research Database (Denmark)

    Kohlmeier, Kristi Anne; Leonard, Christopher S

    2006-01-01

    Nitric oxide synthase (NOS)-containing cholinergic neurons in the laterodorsal tegmentum (LDT) influence behavioral and motivational states through their projections to the thalamus, ventral tegmental area and a brainstem 'rapid eye movement (REM)-induction' site. Action potential-evoked intracel......Nitric oxide synthase (NOS)-containing cholinergic neurons in the laterodorsal tegmentum (LDT) influence behavioral and motivational states through their projections to the thalamus, ventral tegmental area and a brainstem 'rapid eye movement (REM)-induction' site. Action potential......-evoked intracellular calcium transients dampen excitability and stimulate NO production in these neurons. In this study, we investigated the action of several arousal-related neurotransmitters and the role of specific calcium channels in these LDT Ca(2+)-transients by simultaneous whole-cell recording and calcium...... of cholinergic LDT neurons and that inhibition of spike-evoked Ca(2+)-transients is a common action of neurotransmitters that also activate GIRK channels in these neurons. Because spike-evoked calcium influx dampens excitability, our findings suggest that these 'inhibitory' transmitters could boost firing rate...

  18. 5GHz LTCC-based aperture coupled wireless transmitter for system-on-package applications

    KAUST Repository

    Shamim, Atif

    2012-01-01

    A novel System-on-Package (SoP) implementation is presented for a transmitter (TX) module which makes use of electromagnetic coupling between the TX chip and the package antenna. The TX chip is realized in 0.13μm CMOS process and comprises an on-chip antenna, which serves as the oscillator\\'s inductor as well. The TX chip is housed in a Low Temperature Co-fired Ceramic (LTCC) package with a patch antenna. The on-chip antenna feeds the LTCC patch antenna through aperture coupling, thus negating the need for RF buffer amplifiers, matching elements, baluns, bond wires and package transmission lines. This is the first ever demonstration of wireless-interconnect between on-chip and package antennas which increases the gain and range of the TX module manyfold with respect to the on-chip antenna alone. Though the range of the TX SoP increases considerably, power consumption remains the same as that of the TX chip only. A simple analytical model for the new wireless-interconnect has been developed which helps determine the optimum position of the chip with respect to the aperture in the ground plane.

  19. Reactive oxygen radicals and gaseous transmitters in carotid body activation by intermittent hypoxia.

    Science.gov (United States)

    Prabhakar, Nanduri R; Peng, Ying-Jie; Yuan, Guoxiang; Nanduri, Jayasri

    2018-05-01

    Sleep apnea is a prevalent respiratory disease characterized by periodic cessation of breathing during sleep causing intermittent hypoxia (IH). Sleep apnea patients and rodents exposed to IH exhibit elevated sympathetic nerve activity and hypertension. A heightened carotid body (CB) chemoreflex has been implicated in causing autonomic abnormalities in IH-treated rodents and in sleep apnea patients. The purpose of this article is to review the emerging evidence showing that interactions between reactive oxygen species (ROS) and gaseous transmitters as a mechanism cause hyperactive CB by IH. Rodents treated with IH exhibit markedly elevated ROS in the CB, which is due to transcriptional upregulation of pro-oxidant enzymes by hypoxia-inducible factor (HIF)-1 and insufficient transcriptional regulation of anti-oxidant enzymes by HIF-2. ROS, in turn, increases cystathionine γ-lyase (CSE)-dependent H 2 S production in the CB. Blockade of H 2 S synthesis prevents IH-evoked CB activation. However, the effects of ROS on H 2 S production are not due to direct effects on CSE enzyme activity but rather due to inactivation of heme oxygenase-2 (HO-2), a carbon monoxide (CO) producing enzyme. CO inhibits H 2 S production through inactivation of CSE by PKG-dependent phosphorylation. During IH, reduced CO production resulting from inactivation of HO-2 by ROS releases the inhibition of CO on CSE thereby increasing H 2 S. Inhibiting H 2 S synthesis prevented IH-evoked sympathetic activation and hypertension.

  20. Energy transmittance predicts conductive hearing loss in older children and adults

    Science.gov (United States)

    Keefe, Douglas H.; Simmons, Jeffrey L.

    2003-12-01

    The test performance of a wideband acoustic transfer function (ATF) test and 226-Hz tympanometry was assessed in predicting the presence of conductive hearing loss, based on an air-bone gap of 20 dB or more. Two ATF tests were designed using an improved calibration method over a frequency range (0.25-8 kHz): an ambient-pressure test and a tympanometric test using an excess static pressure in the ear canal. Wideband responses were objectively classified using moment analyses of energy transmittance, which was a more appropriate test variable than energy reflectance. Subjects included adults and children of age 10 years and up, with 42 normal-functioning ears and 18 ears with a conductive hearing loss. Predictors were based on the magnitudes of the moment deviations from the 10th to 90th percentiles of the normal group. Comparing tests at a fixed specificity of 0.90, the sensitivities were 0.28 for peak-compensated static acoustic admittance at 226 Hz, 0.72 for ambient-pressure ATF, and 0.94 for pressurized ATF. Pressurized ATF was accurate at predicting conductive hearing loss with an area under the receiver operating characteristic curve of 0.95. Ambient-pressure ATF may have sufficient accuracy to use in some hearing-screening applications, whereas pressurized ATF has additional accuracy that may be appropriate for hearing-diagnostic applications.

  1. Measurement of thermal transmittance of opaque facade wall relationship with meteorological conditions

    Directory of Open Access Journals (Sweden)

    Antunović Biljana S.

    2015-01-01

    Full Text Available This paper presents the results of measurements of thermal transmittance or as otherwise called U-value [W/m2⋅K] of opaque facade wall of preschool institution built in 1977. The building has an incomplete technical documentation according to which considered wall was built of brick and masonry mortar. Thermal characteristics of the incorporated materials have not been specified. Considering that in the period of building construction JUS standards was used, a possible range of calculated U-vales was obtained (1,241-1,404 W/m2·K. Measurements were performed in accordance with ISO 9869 during three time periods with the resulting U-values (1,269±0,276 W/m2·K; 1,025±0,175 W/m2·K; 1,200±0,212 W/m2·K that do not differ from each other within experimental uncertainty. Furthermore, the correlation of the measured U-values and meteorological conditions that prevailed during the measurements was analyzed. In the second measurement period, the average values of the total cloud cover and low cloud cover were less, and the average duration of sunshine was longer than in the other two measurement periods.

  2. 5GHz LTCC-based aperture coupled wireless transmitter for system-on-package applications

    KAUST Repository

    Shamim, Atif; Arsalan, Muhammad; Hojjat, Nasrin; Roy, Langis

    2012-01-01

    A novel System-on-Package (SoP) implementation is presented for a transmitter (TX) module which makes use of electromagnetic coupling between the TX chip and the package antenna. The TX chip is realized in 0.13μm CMOS process and comprises an on-chip antenna, which serves as the oscillator's inductor as well. The TX chip is housed in a Low Temperature Co-fired Ceramic (LTCC) package with a patch antenna. The on-chip antenna feeds the LTCC patch antenna through aperture coupling, thus negating the need for RF buffer amplifiers, matching elements, baluns, bond wires and package transmission lines. This is the first ever demonstration of wireless-interconnect between on-chip and package antennas which increases the gain and range of the TX module manyfold with respect to the on-chip antenna alone. Though the range of the TX SoP increases considerably, power consumption remains the same as that of the TX chip only. A simple analytical model for the new wireless-interconnect has been developed which helps determine the optimum position of the chip with respect to the aperture in the ground plane.

  3. A 24 GHz CMOS oscillator transmitter with an inkjet printed on-chip antenna

    KAUST Repository

    Ghaffar, Farhan A.

    2016-08-15

    CMOS based RF circuits have demonstrated efficient performance over the decades. However, one bottle neck with this technology is its lossy nature for passive components such as inductors, antennas etc. Due to this drawback, passives are either implemented off chip or the designers work with the inefficient passives. This problem can be alleviated by using inkjet printing as a post process on CMOS chip. In this work, we demonstrate inkjet printing of a patterned polymer (SU8) layer on a 24 GHz oscillator chip to isolate the lossy Si substrate from the passives which are inkjet printed on top of the SU8 layer. As a proof of concept, a monopole antenna is printed on top of the SU8 layer integrating it with the oscillator through the exposed RF pads to realize an oscillator transmitter. The proposed hybrid fabrication technique can be extended to multiple dielectric and conductive printed layers to demonstrate complete RF systems on CMOS chips which are efficient, cost-effective and above all small in size. © 2016 IEEE.

  4. Auditory detection of ultrasonic coded transmitters by seals and sea lions.

    Science.gov (United States)

    Cunningham, Kane A; Hayes, Sean A; Michelle Wargo Rub, A; Reichmuth, Colleen

    2014-04-01

    Ultrasonic coded transmitters (UCTs) are high-frequency acoustic tags that are often used to conduct survivorship studies of vulnerable fish species. Recent observations of differential mortality in tag control studies suggest that fish instrumented with UCTs may be selectively targeted by marine mammal predators, thereby skewing valuable survivorship data. In order to better understand the ability of pinnipeds to detect UCT outputs, behavioral high-frequency hearing thresholds were obtained from a trained harbor seal (Phoca vitulina) and a trained California sea lion (Zalophus californianus). Thresholds were measured for extended (500 ms) and brief (10 ms) 69 kHz narrowband stimuli, as well as for a stimulus recorded directly from a Vemco V16-3H UCT, which consisted of eight 10 ms, 69 kHz pure-tone pulses. Detection thresholds for the harbor seal were as expected based on existing audiometric data for this species, while the California sea lion was much more sensitive than predicted. Given measured detection thresholds of 113 dB re 1 μPa and 124 dB re 1 μPa, respectively, both species are likely able to detect acoustic outputs of the Vemco V16-3H under water from distances exceeding 200 m in typical natural conditions, suggesting that these species are capable of using UCTs to detect free-ranging fish.

  5. Exposure of the general public to digital broadcast transmitters compared to analogue ones

    International Nuclear Information System (INIS)

    Schubert, M.; Bornkessel, C.; Wuschek, M.; Schmidt, P.

    2007-01-01

    The terrestrial digital video and audio broadcast are supposed to replace the existing analogue broadcast systems. To determine possible changes of this switch-over on the public exposure situation to radio frequency electromagnetic fields, extensive measurements at more than 300 identical points were performed 'before' and accordingly 'after' the switch-over. At the point with the highest sum-exposure, only 0.3% of the ICNIRP reference levels for general public exposure (power flux density) was reached. The statistical analysis of both measurement campaigns ('before-after') shows an increase in mean exposure in the centre of the DVB-T starting areas around Nuremberg and Munich, which is mainly based on the increase in the radiated power at the transmitter stations. After developing a simple calculation program based on the ITU-RP.1546, the measured exposure values were compared to calculations. Optimising the results leads to mean deviations of ±3 dB at about 80% of all points. (authors)

  6. Distinct transmitter release properties determine differences in short-term plasticity at functional and silent synapses.

    Science.gov (United States)

    Cabezas, Carolina; Buño, Washington

    2006-05-01

    Recent evidence suggests that functional and silent synapses are not only postsynaptically different but also presynaptically distinct. The presynaptic differences may be of functional importance in memory formation because a proposed mechanism for long-term potentiation is the conversion of silent synapses into functional ones. However, there is little direct experimentally evidence of these differences. We have investigated the transmitter release properties of functional and silent Schaffer collateral synapses and show that on the average functional synapses displayed a lower percentage of failures and higher excitatory postsynaptic current (EPSC) amplitudes than silent synapses at +60 mV. Moreover, functional but not silent synapses show paired-pulse facilitation (PPF) at +60 mV and thus presynaptic short-term plasticity will be distinct in the two types of synapse. We examined whether intraterminal endoplasmic reticulum Ca2+ stores influenced the release properties of these synapses. Ryanodine (100 microM) and thapsigargin (1 microM) increased the percentage of failures and decreased both the EPSC amplitude and PPF in functional synapses. Caffeine (10 mM) had the opposite effects. In contrast, silent synapses were insensitive to both ryanodine and caffeine. Hence we have identified differences in the release properties of functional and silent synapses, suggesting that synaptic terminals of functional synapses express regulatory molecular mechanisms that are absent in silent synapses.

  7. Performance characteristics of the 12 GHz, 200 watt Transmitter Experiment Package for CTS. [Communication Technology Satellite

    Science.gov (United States)

    Miller, E. F.; Fiala, J. L.; Hansen, I. G.

    1975-01-01

    Measured performance characteristics from ground test of the Transmitter Experiment Package (TEP) for the Communications Technology Satellite are presented. The experiment package consists of a 200 W Output Stage Tube (OST) powered by a Power Processing System (PPS). Descriptions of both the PPS and OST are given. The PPS provides the necessary voltages with a measured dc/dc conversion efficiency of 89 per cent. The OST, a traveling wave tube with multiple collectors, has a saturated rf output power of 224 W and operates at an overall efficiency exceeding 40 per cent over an 85 MHz bandwidth at 12 GHz. OST performance given includes frequency response, saturation characteristics, group delay, AM to PM conversion, intermodulation distortion, and two channel gain suppression. Single and dual channel FM video performance is presented. It was determined that for 12 MHz peak to peak frequency deviation on each channel, dual channel FM television signals can be transmitted through the TEP at 60 W, each channel, with 40 MHz channel spacing (center to center).

  8. Calculation of Reflectance and Transmittance of Coating With Optically Rough Surfaces

    International Nuclear Information System (INIS)

    El-Depsy, A.; Shawky, A.M.

    2011-01-01

    For ideal surfaces, components of the reflected beam are related to the components of the incident beam by Fresnel reflection equation. The surfaces encountered in engineering applications deviate from ideal as a result of roughness, oxidization and contamination; hence the Radiative properties of these real surfaces differ greatly from those predicted by electromagnetic theory. In regard to problems of radiative heat transfer; the roughness of surfaces may be divided into two categories: (1) small surface irregularities such that the incident radiation cannot undergo more than a single reflection, (2) deep cavities in which the incident radiation undergoes multi-reflection. The normally incident radiation from rough surface having small irregularities is reflected partly specularly and partly diffusely [1]. Kubelka-Munk theory (K-M) [2] describes optical characteristics (e.g. reflectance, transmittance and absorbance) by a variety of light scattering media including paints, textiles and papers, and It is widely used in various industrial applications. Moder developments in radiative transfer theory (RTT) enable the derivation of (K-M) parameters from first principles [3]. Kubelka and Munk proposed a theory based on a model of two light fluxes travelling in the forward and backward directions. Subsequently a number of authors refined the theory and compared it with experimental data [4]. Several authors attempted to relate the Kubelka- Munk coefficients to the transport coefficients [5,6

  9. Performance Analysis of Multiradio Transmitter with Polar or Cartesian Architectures Associated with High Efficiency Switched-Mode Power Amplifiers (invited paper

    Directory of Open Access Journals (Sweden)

    F. Robert

    2010-12-01

    Full Text Available This paper deals with wireless multi-radio transmitter architectures operating in the frequency band of 800 MHz – 6 GHz. As a consequence of the constant evolution in the communication systems, mobile transmitters must be able to operate at different frequency bands and modes according to existing standards specifications. The concept of a unique multiradio architecture is an evolution of the multistandard transceiver characterized by a parallelization of circuits for each standard. Multi-radio concept optimizes surface and power consumption. Transmitter architectures using sampling techniques and baseband ΣΔ or PWM coding of signals before their amplification appear as good candidates for multiradio transmitters for several reasons. They allow using high efficiency power amplifiers such as switched-mode PAs. They are highly flexible and easy to integrate because of their digital nature. But when the transmitter efficiency is considered, many elements have to be taken into account: signal coding efficiency, PA efficiency, RF filter. This paper investigates the interest of these architectures for a multiradio transmitter able to support existing wireless communications standards between 800 MHz and 6 GHz. It evaluates and compares the different possible architectures for WiMAX and LTE standards in terms of signal quality and transmitter power efficiency.

  10. Infrared-transmittance tunable metal-insulator conversion device with thin-film-transistor-type structure on a glass substrate

    Directory of Open Access Journals (Sweden)

    Takayoshi Katase

    2017-05-01

    Full Text Available Infrared (IR transmittance tunable metal-insulator conversion was demonstrated on a glass substrate by using thermochromic vanadium dioxide (VO2 as the active layer in a three-terminal thin-film-transistor-type device with water-infiltrated glass as the gate insulator. Alternative positive/negative gate-voltage applications induce the reversible protonation/deprotonation of a VO2 channel, and two-orders of magnitude modulation of sheet-resistance and 49% modulation of IR-transmittance were simultaneously demonstrated at room temperature by the metal-insulator phase conversion of VO2 in a non-volatile manner. The present device is operable by the room-temperature protonation in an all-solid-state structure, and thus it will provide a new gateway to future energy-saving technology as an advanced smart window.

  11. Fluctuations of Internal Transmittance in Security of Measurement-Device-Independent Quantum Key Distribution with an Untrusted Source*

    International Nuclear Information System (INIS)

    Wang Yang; Bao Wan-Su; Chen Rui-Ke; Zhou Chun; Jiang Mu-Sheng; Li Hong-Wei

    2017-01-01

    Measurement-device-independent quantum key distribution (MDI-QKD) is immune to detector side channel attacks, which is a crucial security loophole problem in traditional QKD. In order to relax a key assumption that the sources are trusted in MDI-QKD, an MDI-QKD protocol with an untrusted source has been proposed. For the security of MDI-QKD with an untrusted source, imperfections in the practical experiment should also be taken into account. In this paper, we analyze the effects of fluctuations of internal transmittance on the security of a decoy-state MDI-QKD protocol with an untrusted source. Our numerical results show that both the secret key rate and the maximum secure transmission distance decrease when taken fluctuations of internal transmittance into consideration. Especially, they are more sensitive when Charlie’s mean photon number per pulse is smaller. Our results emphasize that the stability of correlative optical devices is important for practical implementations . (paper)

  12. Aging and environmental tolerance of an optical transmitter for the ATLAS Phase-I upgrade at the LHC

    Energy Technology Data Exchange (ETDEWEB)

    Chang, F.X. [Academia Sinica, Taipei, Taiwan (China); Chang, H.T. [Liverage Technology Inc., Chupei, Taiwan (China); Duh, T.S. [Institute of Nuclear Energy Research, Longtan, Taiwan (China); Hayamizu, T. [CYRIC, Tohoku University, Sendai (Japan); Hou, S. [Academia Sinica, Taipei, Taiwan (China); Hu, X. [Michigan University, Ann Arbor, MI (United States); Liu, C.; Liu, T. [Southern Methodist University, Dallas, TX (United States); Sakemi, Y. [CYRIC, Tohoku University, Sendai (Japan); Schwarz, T. [Michigan University, Ann Arbor, MI (United States); Teng, P.K.; Tsai, P.R. [Academia Sinica, Taipei, Taiwan (China); Wang, C.H. [National United University, Miaoli, Taiwan (China); Wang, S.Y. [Liverage Technology Inc., Chupei, Taiwan (China); Yang, Y. [National Cheng Kung University, Tainan, Taiwan (China); Ye, J. [Southern Methodist University, Dallas, TX (United States)

    2016-09-21

    The dual channel Miniature optical Transmitter (MTx) is developed for the ATLAS Phase-I upgrade requiring durable performance in the Large Hadron Collider environment. The data transmission has achieved 8 Gbps per channel with a custom-designed LOCld laser driver and 850 nm VCSELs packaged in transmitter optical sub-assemblies (TOSAs). The performance of the MTx opto-electronics is evaluated. Accelerated aging tests of the VCSELs were conducted in a chamber at 85 °C, 85% relative humidity, with TOSA and bare-die samples prepared in non-hermetic condition. Radiation tolerance of the VCSELs was investigated with 30 MeV and 70 MeV protons. The radiation induced effects in data transmission were investigated for light-power degradation and parameters of eye-diagrams.

  13. Deposition of low stress, high transmittance SiC as an x-ray mask membrane using ECR plasma CVD

    CERN Document Server

    Lee, S Y; Lim, S T; Ahn, J H

    1998-01-01

    SiC for x-ray mask membrane is deposited by Electron Cyclotron Resonance plasma Chemical Vapor Deposition from SiH sub 4 /CH sub 4 Ar mixtures. Stoichiometric SiC is deposited at SiH sub 4 /CH sub 4 ratio of 0.4, deposition temperature of 600.deg.C and microwave power of 500 W with +- 5% thickness uniformity, As-deposited film has compressive residual stress, very smooth surface (31 A rms) and high optical transmittance of 90% at 633 nm wavelength. The microstructure of this film consists of the nanocrystalline particle (100 A approx 200A) embedded in amorphous matrix. Residual stress can be turned to tensile stress via Rapid Thermal Annealing in N sub 2 atmosphere, while suppressing structural change during annealing, As a result, smooth (37 A rms) SiC film with moderate tensile stress and high optical transmittance (85% at 633 nm wavelength) is obtained.

  14. Near-UV Transmittance of Basalt Dust as an Analog of the Martian Regolith: Implications for Sensor Calibration and Astrobiology

    Directory of Open Access Journals (Sweden)

    J. Martínez-Frías

    2006-06-01

    Full Text Available The Martian regolith is exposed to solar irradiation in the near-UV (200-390 nm.Basalt is one of the main components of the dust on Mars surface. The near-UV irradiationof basalt dust on Mars is simulated experimentally in order to determine the transmittance asa function of the mass and thickness of the dust. This data can serve to quantify theabsorption of dust deposited on sensors aiming to measure the UV intensity on Marssurface. The minimum thickness of the dust that corresponds to near-zero-transmittance inthe near-UV is measured. Hypothetical Martian microorganisms living on the dusty regolithat deeper layers would be preserved from the damaging solar UV irradiation.

  15. Visible and near-infrared spectroscopic analysis of raw milk for cow health monitoring: reflectance or transmittance?

    Science.gov (United States)

    Aernouts, B; Polshin, E; Lammertyn, J; Saeys, W

    2011-11-01

    The composition of produced milk has great value for the dairy farmer. It determines the economic value of the milk and provides valuable information about the metabolism of the corresponding cow. Therefore, online measurement of milk components during milking 2 or more times per day would provide knowledge about the current health and nutritional status of each cow individually. This information provides a solid basis for optimizing cow management. The potential of visible and near-infrared (Vis/NIR) spectroscopy for predicting the fat, crude protein, lactose, and urea content of raw milk online during milking was, therefore, investigated in this study. Two measurement modes (reflectance and transmittance) and different wavelength ranges for Vis/NIR spectroscopy were evaluated and their ability to measure the milk composition online was compared. The Vis/NIR reflectance measurements allowed for very accurate monitoring of the fat and crude protein content in raw milk (R(2)>0.95), but resulted in poor lactose predictions (R(2)milk samples gave accurate fat and crude protein predictions (R(2)>0.90) and useful lactose predictions (R(2)=0.88). Neither Vis/NIR reflectance nor transmittance spectroscopy lead to an acceptable prediction of the milk urea content. Transmittance spectroscopy can thus be used to predict the 3 major milk components, but with lower accuracy for fat and crude protein than the reflectance mode. Moreover, the small sample thickness (1mm) required for NIR transmittance measurement considerably complicates its online use. Copyright © 2011 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  16. Emission of parasitic X-rays from military radar transmitters and exposure of personnel: towards a retrospective assessment

    Energy Technology Data Exchange (ETDEWEB)

    Schirmer, A. [Arbeitsgruppe Aufklarung der Arbeitsplatzverhaltnisse Radar, Wehrbereichsverwaltung Nord, Bundeswehr, Munster (Germany)

    2006-07-01

    An overview of the investigation of parasitic-X-ray (Bremsstrahlung) from high-voltage electron vacuum tubes in military radar transmitters is given. From technical inspection, data evaluation and measurements maximum dose rates for work places of the personnel are calculated. With dedicated workplace surveys the maximum dose H{sup *}(10) per month for the personnel is estimated for the entire time of use of the different radar sets. (author)

  17. Emission of parasitic X-rays from military radar transmitters and exposure of personnel: towards a retrospective assessment

    International Nuclear Information System (INIS)

    Schirmer, A.

    2006-01-01

    An overview of the investigation of parasitic-X-ray (Bremsstrahlung) from high-voltage electron vacuum tubes in military radar transmitters is given. From technical inspection, data evaluation and measurements maximum dose rates for work places of the personnel are calculated. With dedicated workplace surveys the maximum dose H * (10) per month for the personnel is estimated for the entire time of use of the different radar sets. (author)

  18. Forward Behavioral Modeling of a Three-Way Amplitude Modulator-Based Transmitter Using an Augmented Memory Polynomial

    Directory of Open Access Journals (Sweden)

    Jatin Chatrath

    2018-03-01

    Full Text Available Reconfigurable and multi-standard RF front-ends for wireless communication and sensor networks have gained importance as building blocks for the Internet of Things. Simpler and highly-efficient transmitter architectures, which can transmit better quality signals with reduced impairments, are an important step in this direction. In this regard, mixer-less transmitter architecture, namely, the three-way amplitude modulator-based transmitter, avoids the use of imperfect mixers and frequency up-converters, and their resulting distortions, leading to an improved signal quality. In this work, an augmented memory polynomial-based model for the behavioral modeling of such mixer-less transmitter architecture is proposed. Extensive simulations and measurements have been carried out in order to validate the accuracy of the proposed modeling strategy. The performance of the proposed model is evaluated using normalized mean square error (NMSE for long-term evolution (LTE signals. NMSE for a LTE signal of 1.4 MHz bandwidth with 100,000 samples for digital combining and analog combining are recorded as −36.41 dB and −36.9 dB, respectively. Similarly, for a 5 MHz signal the proposed models achieves −31.93 dB and −32.08 dB NMSE using digital and analog combining, respectively. For further validation of the proposed model, amplitude-to-amplitude (AM-AM, amplitude-to-phase (AM-PM, and the spectral response of the modeled and measured data are plotted, reasonably meeting the desired modeling criteria.

  19. Sensitivity Range Analysis of Infrared (IR) Transmitter and Receiver Sensor to Detect Sample Position in Automatic Sample Changer

    International Nuclear Information System (INIS)

    Syirrazie Che Soh; Nolida Yussup; Nur Aira Abdul Rahman; Maslina Ibrahim

    2016-01-01

    Sensitivity range of IR Transmitter and Receiver Sensor influences the effectiveness of the sensor to detect position of a sample. Then the purpose of this analysis is to determine the suitable design and specification the electronic driver of the sensor to gain appropriate sensitivity range for required operation. The related activities to this analysis cover electronic design concept and specification, calibration of design specification and evaluation on design specification for required application. (author)

  20. A 10.6mm3 Fully-Integrated, Wireless Sensor Node with 8GHz UWB Transmitter.

    Science.gov (United States)

    Kim, Hyeongseok; Kim, Gyouho; Lee, Yoonmyung; Foo, Zhiyoong; Sylvester, Dennis; Blaauw, David; Wentzloff, David

    2015-06-01

    This paper presents a complete, autonomous, wireless temperature sensor, fully encapsulated in a 10.6mm 3 volume. The sensor includes solar energy harvesting with an integrated 2 μAh battery, optical receiver for programming, microcontroller and memory, 8GHz UWB transmitter, and miniaturized custom antennas with a wireless range of 7 meters. Full, stand-alone operation was demonstrated for the first time for a system of this size and functionality.

  1. Hybrid recursive active filters for duplexing in RF transmitter front-ends

    Science.gov (United States)

    Gottardo, Giuseppe; Donati, Giovanni; Musolff, Christian; Fischer, Georg; Felgentreff, Tilman

    2016-08-01

    Duplex filters in modern base transceiver stations shape the channel in order to perform common frequency division duplex operations. Usually, they are designed as cavity filters, which are expensive and have large dimensions. Thanks to the emerging digital technology and fast digital converters, it is possible to transfer the efforts of designing analog duplex filters into digital numeric algorithms applied to feedback structures, operating on power. This solution provides the shaping of the signal spectrum directly at the output of the radio frequency (RF) power amplifiers (PAs) relaxing the transmitter design especially in the duplexer and in the antenna sections. The design of a digital baseband feedback applied to the analog power RF amplifiers (hybrid filter) is presented and verified by measurements. A model to describe the hybrid system is investigated, and the relation between phase and resonance peaks of the resulting periodic band-pass transfer function is described. The stability condition of the system is analyzed using Nyquist criterion. A solution involving a number of digital feedback and forward branches is investigated defining the parameters of the recursive structure. This solution allows the closed loop system to show a periodic band pass with up to 500 kHz bandwidth at the output of the RF amplifier. The band-pass magnitude reaches up to 17 dB selectivity. The rejection of the PA noise in the out-of-band frequencies is verified by measurements. The filter is tested with a modulated LTE (Long Term Evolution) signal showing an ACPR (Adjacent Channel Power Ratio) enhancement of 10 dB of the transmitted signal.

  2. Low SWaP Semiconductor Laser Transmitter Modules For ASCENDS Mission Applications

    Science.gov (United States)

    Prasad, Narasimha S.; Rosiewicz, Alex; Coleman, Steven M.

    2012-01-01

    The National Research Council's (NRC) Decadal Survey (DS) of Earth Science and Applications from Space has identified the Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) as an important atmospheric science mission. NASA Langley Research Center, working with its partners, is developing fiber laser architecture based intensity modulated CW laser absorption spectrometer for measuring XCO2 in the 1571 nm spectral band. In support of this measurement, remote sensing of O2 in the 1260 nm spectral band for surface pressure measurements is also being developed. In this paper, we will present recent progress made in the development of advanced transmitter modules for CO2 and O2 sensing. Advanced DFB seed laser modules incorporating low-noise variable laser bias current supply and low-noise variable temperature control circuit have been developed. The 1571 nm modules operate at >80 mW and could be tuned continuously over the wavelength range of 1569-1574nm at a rate of 2 pm/mV. Fine tuning was demonstrated by adjusting the laser drive at a rate of 0.7 pm/mV. Heterodyne linewidth measurements have been performed showing linewidth 200 kHz and frequency jitter 75 MHz. In the case of 1260 nm DFB laser modules, we have shown continuous tuning over a range of 1261.4 - 1262.6 nm by changing chip operating temperature and 1261.0 - 1262.0 nm by changing the laser diode drive level. In addition, we have created a new laser package configuration which has been shown to improve the TEC coefficient of performance by a factor of 5 and improved the overall efficiency of the laser module by a factor of 2.

  3. Seasonality of light transmittance through Arctic sea ice during spring and summe

    Science.gov (United States)

    Nicolaus, M.; Hudson, S. R.; Granskog, M. A.; Pavlov, A.; Taskjelle, T.; Kauko, H.; Katlein, C.; Geland, S.; Perovich, D. K.

    2017-12-01

    The energy budget of sea ice and the upper ocean during spring, summer, and autumn is strongly affected by the transfer of solar shortwave radiation through sea ice and into the upper ocean. Previous studies highlighted the great importance of the spring-summer transition, when incoming fluxes are highest and even small changes in surface albedo and transmittance have strong impacts on the annual budgets. The timing of melt onset and changes in snow and ice conditions are also crucial for primary productivity and biogeochemical processes. Here we present results from time series measurements of radiation fluxes through seasonal Arctic sea ice, as it may be expected to play a key role in the future Arctic. Our observations were performed during the Norwegian N-ICE drift experiment in 2015 and the Polarstern expedition PS106 in 2017, both studying sea ice north of Svalbard. Autonomous stations were installed to monitor spectral radiation fluxes above and under sea ice. The observation periods cover the spring-summer transition, including snow melt and early melt pond formation. The results show the direct relation of optical properties to under ice algae blooms and their influence on the energy budget. Beyond these results, we will discuss the latest plans and implementation of radiation measurements during the MOSAiC drift in 2019/2020. Then, a full annual cycle of radiation fluxes may be studied from manned and autonomous (buoys) measurements as well as using a remotely operated vehicle (ROV) as measurement platform. These measurements will be performed in direct relation with numerical simulations on different scales.

  4. REMIT5.1, Radiation exposure monitoring and information transmittal system

    International Nuclear Information System (INIS)

    2007-01-01

    1 - Description of program or function - The Radiation Exposure Monitoring and Information Transmittal (REMIT) is a PC-based menu driven system that facilitates the manipulation of data base files to record and report radiation exposure information. REMIT is designed to be user-friendly and contains the full text of Regulatory Guide 8.7, Rev.1, on-line as well as context-sensitive help throughout the program. The user can enter data directly from NRC Forms 4 or 5. REMIT allows the user to view the individual's exposure in relation to regulatory or administrative limits and will alert the user to exposures in excess of these limits. The system also provides for the calculation and summation of dose from intakes and the determination of the dose to the maximally exposed extremity for the monitoring year. REMIT can produce NRC Forms 4 and 5 in paper and electronic format and can import/export data from ASCII and data base files. Additional information is available from the web page www.reirs.com. REMIT system is designed to assist U.S. Nuclear Regulatory Commission (NRC) licensees in meeting the reporting requirements of the Revised 10 CFR Parts 20.1001 through 20.2401 as outlined in Regulatory Guide 8.7, Rev.1, Instructions for Recording and Reporting Occupational Exposure Data. 2 - Methods - REMIT makes use of the dose conversion factors from EPA Report 11 Limiting Values of Radionuclide Intake and Air Concentration and Dose Conversion Factors for Inhalation, Submission, and Ingestion, to calculate the Committed Dose Equivalent to the maximally exposed organ and the Committed Effective Dose Equivalent from intakes measured in microcuries. REMIT also estimates the amount (in micrograms) of uranium intake from the activity entered in microcuries. This calculation is based on the specific activities of the uranium isotopes. 3 - Restrictions on the complexity of the problem - None noted

  5. Equalization of Multiuser Wireless CDMA Downlink Considering Transmitter Nonlinearity Using Walsh Codes

    Directory of Open Access Journals (Sweden)

    Pinter Stephen Z

    2007-01-01

    Full Text Available Transmitter nonlinearity has been a major issue in many scenarios: cellular wireless systems have high power RF amplifier (HPA nonlinearity at the base station; satellite downlinks have nonlinear TWT amplifiers in the satellite transponder and multipath conditions in the ground station; and radio-over-fiber (ROF systems consist of a nonlinear optical link followed by a wireless channel. In many cases, the nonlinearity is simply ignored if there is no out-of-band emission. This results in poor BER performance. In this paper we propose a new technique to estimate the linear part of the wireless downlink in the presence of a nonlinearity using Walsh codes; Walsh codes are commonly used in CDMA downlinks. Furthermore, we show that equalizer performance is significantly improved by taking into account the presence of the nonlinearity during channel estimation. This is shown by using a regular decision feedback equalizer (DFE with both wireless and RF amplifier noise. We perform estimation in a multiuser CDMA communication system where all users transmit their signal simultaneously. Correlation analysis is applied to identify the channel impulse response (CIR and the derivation of key correlation relationships is shown. A difficulty with using Walsh codes in terms of their correlations (compared to PN sequences is then presented, as well as a discussion on how to overcome it. Numerical evaluations show a good estimation of the linear system with 54 users in the downlink and a signal-to-noise ratio (SNR of 25 dB. Bit error rate (BER simulations of the proposed identification and equalization algorithms show a BER of achieved at an SNR of dB.

  6. Use of shock block transmitters in the structural rehabilitation of historical buildings in Calabria and Sicily

    International Nuclear Information System (INIS)

    Bianco, Alessia; Candela, Michele; Fonti, Roberta

    2008-01-01

    Many old and historical masonry buildings, located in the Calabrian and Sicilian areas near the strait of Messina, are affected by typical pattern of cracks, which are not produced by previous earthquakes. These cracks in the masonry walls are characterized by a quasi-vertical trend with constant width. The careful examination of the crack distribution allows to clearly identify the diagnosis: the damage is caused by the sinking due to a horizontal movement of translation of the ground, which is an evident effect of creep phenomena in the soil, so-called 'solifluxion'. This paper, after showing this geological pathology, proposes an innovative strategy of intervention, which consists of the use of 'oleo-dynamic' devices, so-called shock block transmitters, providing different degrees of restraint, according to the loading conditions. In addition, in case of earthquake, an important part of the in-put seismic energy can be dissipated. The strategy of application of this system to the building consists of the subdivision of each masonry wall in two different parts, which are physically separated by the cracks. Each wall portion must be consolidated separately and the different parts of walls behave as statically independent each other, so that they can move independently during the serviceability conditions. The connection among the walls composing the whole structural organism is given by metal tie-rods equipped with 'oleo dynamic' devices, which allows, in a given range, the horizontal sliding in case of slow movement due to the phenomenon of 'solifluxion'. Contrary, in case of dynamic and fast movements, such as the ones produced by an earthquake, each 'oleo dynamic' device provides a fully restraint effect and, as a consequence, the tie-rods behave in the classical way

  7. Analysis of ecstasy tablets: comparison of reflectance and transmittance near infrared spectroscopy.

    Science.gov (United States)

    Schneider, Ralph Carsten; Kovar, Karl-Artur

    2003-07-08

    Calibration models for the quantitation of commonly used ecstasy substances have been developed using near infrared spectroscopy (NIR) in diffuse reflectance and in transmission mode by applying seized ecstasy tablets for model building and validation. The samples contained amphetamine, N-methyl-3,4-methylenedioxy-amphetamine (MDMA) and N-ethyl-3,4-methylenedioxy-amphetamine (MDE) in different concentrations. All tablets were analyzed using high performance liquid chromatography (HPLC) with diode array detection as reference method. We evaluated the performance of each NIR measurement method with regard to its ability to predict the content of each tablet with a low root mean square error of prediction (RMSEP). Best calibration models could be generated by using NIR measurement in transmittance mode with wavelength selection and 1/x-transformation of the raw data. The models build in reflectance mode showed higher RMSEPs using as data pretreatment, wavelength selection, 1/x-transformation and a second order Savitzky-Golay derivative with five point smoothing was applied to obtain the best models. To estimate the influence of inhomogeneities in the illegal tablets, a calibration of the destroyed, i.e. triturated samples was build and compared to the corresponding data of the whole tablets. The calibrations using these homogenized tablets showed lower RMSEPs. We can conclude that NIR analysis of ecstasy tablets in transmission mode is more suitable than measurement in diffuse reflectance to obtain quantification models for their active ingredients with regard to low errors of prediction. Inhomogeneities in the samples are equalized when measuring the tablets as powdered samples.

  8. Design and Development of a Pressure Transmitter Using Modified Inductance Measuring Network and Bellow Sensor

    Directory of Open Access Journals (Sweden)

    Venkata Lakshmi Narayana K.

    2013-03-01

    Full Text Available In this paper, a pressure transmitter using a modified op-amp based network for inductance measurement using a bellow as sensor has been proposed to measure the pressure and to convert pressure changes in to an electrical current which can be transmitted to a remote indicator. The change in inductance due to change in pressure is measured by an improved modified operational amplifier based network. The proposed network permits offset inductance compensation of sensing coil and also minimizes the stray capacitance between sensing coil and ground using dummy inductor whose value equal to zero level inductance of sensing coil and op-amps with high input impedance. In the first part of experiment, a modified op-amp based inductance measuring circuit has been simulated using LabVIEW (Laboratory Virtual Instrument Engineering Workbench and studied with test inductance, and in the second part, the experimentation was done by replacing the test inductance with a sensing coil fitted to bellow by means of ferromagnetic wire for the measurement of pressure. It has been observed that the variation in gauge pressure from 0 to 70 psi having linear relationship with output ac voltage in the range of 0 to 85.0 mV. Corresponding to pressure variations, the ac output voltage further converted into an electric current of 4 to 20 mA for remote indication and control purpose. The investigations have been performed to sense air pressure of pressure tank fitted with pump piston. The experimental results are found to have good linearity of about ± 0.1 % and resolution.

  9. Diurnal changes in epidermal UV transmittance of plants in naturally high UV environments.

    Science.gov (United States)

    Barnes, Paul W; Flint, Stephan D; Slusser, James R; Gao, Wei; Ryel, Ronald J

    2008-06-01

    Studies were conducted on three herbaceous plant species growing in naturally high solar UV environments in the subalpine of Mauna Kea, Hawaii, USA, to determine if diurnal changes in epidermal UV transmittance (T(UV)) occur in these species, and to test whether manipulation of the solar radiation regime could alter these diurnal patterns. Additional field studies were conducted at Logan, Utah, USA, to determine if solar UV was causing diurnal T(UV) changes and to evaluate the relationship between diurnal changes in T(UV) and UV-absorbing pigments. Under clear skies, T(UV), as measured with a UV-A-pulse amplitude modulation fluorometer for leaves of Verbascum thapsus and Oenothera stricta growing in native soils and Vicia faba growing in pots, was highest at predawn and sunset and lowest at midday. These patterns in T(UV) closely tracked diurnal changes in solar radiation and were the result of correlated changes in fluorescence induced by UV-A and blue radiation but not photochemical efficiency (F(v)/F(m)) or initial fluorescence yield (F(o)). The magnitude of the midday reduction in T(UV) was greater for young leaves than for older leaves of Verbascum. Imposition of artificial shade eliminated the diurnal changes in T(UV) in Verbascum, but reduction in solar UV had no effect on diurnal T(UV) changes in Vicia. In Vicia, the diurnal changes in T(UV) occurred without detectable changes in the concentration of whole-leaf UV-absorbing compounds. Results suggest that plants actively control diurnal changes in UV shielding, and these changes occur in response to signals other than solar UV; however, the underlying mechanisms responsible for rapid changes in T(UV) remain unclear.

  10. Spectral broadening of VLF transmitter signals and sideband structure observed on Aureol 3 satellite at middle latitudes

    International Nuclear Information System (INIS)

    Tanaka, Y.; Hayakawa, M.; Lagoutte, D.; Lefeuvre, F.; Tajima, S.

    1987-01-01

    Electric and magnetic field wave data acquired on Aureol 3 satellite demonstrate the existence of a spectral broadening effect in which VLF transmitter signals from Alpha station (geographic coordinates, 50.5 degree N, 137 degree E) in USSR undergo a significant spectral broadening on electric fields as they propagate through the ionosphere up to the spacecraft in the altitude range of 500-2,000 km at middle latitudes (L ∼ 2). The spectral broadening phenomena may be divided into two types: (1) spectrally broadened components occurring without any association with ELF/VLF emissions under disturbed ionospheric conditions and (2) spectrally broadened components with predominant sideband structure in association with ELF emissions. Bicoherence computation results suggest a nonlinear mode coupling between the transmitter signal and ELF emission which produces sidebands that are quasi-electrostatic in nature. However, faint spectral broadened components in both types 1 and 2 may be connected with Doppler shift of quasi-electrostatic whistler mode waves with a broad spectrum of k near the resonance cone, due to scattering of the transmitter signals from ionospheric irregularities in the F region

  11. Voigt equivalent widths and spectral-bin single-line transmittances: Exact expansions and the MODTRAN®5 implementation

    Science.gov (United States)

    Berk, Alexander

    2013-03-01

    Exact expansions for Voigt line-shape total, line-tail and spectral bin equivalent widths and for Voigt finite spectral bin single-line transmittances have been derived in terms of optical depth dependent exponentially-scaled modified Bessel functions of integer order and optical depth independent Fourier integral coefficients. The series are convergent for the full range of Voigt line-shapes, from pure Doppler to pure Lorentzian. In the Lorentz limit, the expansion reduces to the Ladenburg and Reiche function for the total equivalent width. Analytic expressions are derived for the first 8 Fourier coefficients for pure Lorentzian lines, for pure Doppler lines and for Voigt lines with at most moderate Doppler dependence. A strong-line limit sum rule on the Fourier coefficients is enforced to define an additional Fourier coefficient and to optimize convergence of the truncated expansion. The moderate Doppler dependence scenario is applicable to and has been implemented in the MODTRAN5 atmospheric band model radiative transfer software. Finite-bin transmittances computed with the truncated expansions reduce transmittance residuals compared to the former Rodgers-Williams equivalent width based approach by ∼2 orders of magnitude.

  12. Biochemical evidence for glutamate as a transmitter in hippocampal efferents to the basal forebrain and hypothalamus in the rat brain

    Energy Technology Data Exchange (ETDEWEB)

    Walaas, I; Fonnum, F

    1980-01-01

    The effects of bilateral transection of the fornix bundle on the high affinity uptake of glutamate and on the amino acid content in several nuclei of rat forebrain and hypothalamus were studied in order to investigate the possible role of glutamate as a transmitter of these fibres. This lesion decreased the high affinity uptake of L-glutamate by 60 to 70% in the mammillary body and lateral septum, and by 40 to 50% in the anterior diagonal band nucleus, the bed nucleus of the stria terminalis, the mediobasal hypothalamus and the nucleus accumbens. The content of endogenous glutamate in samples dissected from freeze-dried tissue also decreased significantly in these regions. Endogenous aspartate was slightly decreased in the anterior diagonal band nucleus and the mammillary body, but unchanged in the other regions. No significant changes were seen in the levels of serine, ..gamma..-aminobutyric acid, glutamine and taurine, except for an increase in glutamine and taurine in the bed nucleus of the stria terminalis. The high affinity uptake of ..gamma..-aminobutyric acid, tested in the bed nucleus of the stria terminalis, the mediobasal hypothalamus and the mammillary body, was unchanged after the lesion. The results indicate that allocortical efferents innervating subcortial nuclei through the fornix might use glutamate as a transmitter. The study further supports the concept that glutamate plays an important role as transmitter of several different corticofugal fibre systems in mammalian brain.

  13. Enhancement of optical transmittance and electrical resistivity of post-annealed ITO thin films RF sputtered on Si

    Science.gov (United States)

    Ali, Ahmad Hadi; Hassan, Zainuriah; Shuhaimi, Ahmad

    2018-06-01

    This paper reports on the enhancement of optical transmittance and electrical resistivity of indium tin oxide (ITO) transparent conductive oxides (TCO) deposited by radio frequency (RF) sputtering on Si substrate. Post-annealing was conducted on the samples at temperature ranges of 500-700 °C. From X-ray diffraction analysis (XRD), ITO (2 2 2) peak was observed after post-annealing indicating crystallization phase of the films. From UV-vis measurements, the ITO thin film shows highest transmittance of more than 90% at post-annealing temperature of 700 °C as compared to the as-deposited thin films. From atomic force microscope (AFM), the surface roughness becomes smoother after post-annealing as compared to the as-deposited. The lowest electrical resistivity for ITO sample is 6.68 × 10-4 Ω cm after post-annealed at 700 °C that are contributed by high carrier concentration and mobility. The improved structural and surface morphological characteristics helps in increasing the optical transmittance and reducing the electrical resistivity of the ITO thin films.

  14. Fabrication of flexible silver nanowire conductive films and transmittance improvement based on moth-eye nanostructure array

    Science.gov (United States)

    Zhang, Chengpeng; Zhu, Yuwen; Yi, Peiyun; Peng, Linfa; Lai, Xinmin

    2017-07-01

    Transparent conductive electrodes (TCEs) are widely used in optoelectronic devices, such as touch screens, liquid-crystal displays and light-emitting diodes. To date, the material of the most commonly used TCEs was indium-tin oxide (ITO), which had several intrinsic drawbacks that limited its applications in the long term, including relatively high material cost and brittleness. Silver nanowire (AgNW), as one of the alternative materials for ITO TCEs, has already gained much attention all over the world. In this paper, we reported a facile method to greatly enhance the transmittance of the AgNW TCEs without reducing the electrical conductivity based on moth-eye nanostructures, and the moth-eye nanostructures were fabricated by using a roll-to-roll ultraviolet nanoimprint lithography process. Besides, the effects of mechanical pressure and bending on the moth-eye nanostructure layer were also investigated. In the research, the optical transmittance of the flexible AgNW TCEs was enhanced from 81.3% to 86.0% by attaching moth-eye nanostructures onto the other side of the flexible polyethylene terephthalate substrate while the electrical conductivity of the AgNW TCEs was not sacrificed. This research can provide a direction for the cost-effective fabrication of moth-eye nanostructures and the transmittance improvement of the flexible transparent electrodes.

  15. Fabrication of flexible silver nanowire conductive films and transmittance improvement based on moth-eye nanostructure array

    International Nuclear Information System (INIS)

    Zhang, Chengpeng; Zhu, Yuwen; Yi, Peiyun; Peng, Linfa; Lai, Xinmin

    2017-01-01

    Transparent conductive electrodes (TCEs) are widely used in optoelectronic devices, such as touch screens, liquid-crystal displays and light-emitting diodes. To date, the material of the most commonly used TCEs was indium-tin oxide (ITO), which had several intrinsic drawbacks that limited its applications in the long term, including relatively high material cost and brittleness. Silver nanowire (AgNW), as one of the alternative materials for ITO TCEs, has already gained much attention all over the world. In this paper, we reported a facile method to greatly enhance the transmittance of the AgNW TCEs without reducing the electrical conductivity based on moth-eye nanostructures, and the moth-eye nanostructures were fabricated by using a roll-to-roll ultraviolet nanoimprint lithography process. Besides, the effects of mechanical pressure and bending on the moth-eye nanostructure layer were also investigated. In the research, the optical transmittance of the flexible AgNW TCEs was enhanced from 81.3% to 86.0% by attaching moth-eye nanostructures onto the other side of the flexible polyethylene terephthalate substrate while the electrical conductivity of the AgNW TCEs was not sacrificed. This research can provide a direction for the cost-effective fabrication of moth-eye nanostructures and the transmittance improvement of the flexible transparent electrodes. (paper)

  16. Inventarisatie van de flora en fauna in 2002 en 2003 - "De Waalsprong", gemeente Nijmegen; aanwezigheid van beschermde soorten uit de Flora- en Faunawet en de Vogel- en Habitatrichtlijn en aanwijzingen tot het voorkomen van schade aan populaties en mogelijheden voor mitigerende en compenserende maatregelen en pro-actief plannen

    NARCIS (Netherlands)

    Kwak, R.G.M.

    2004-01-01

    In dit rapport worden de resultaten gepresenteerd van een uitgebreide jaar-rond inventarisatie van flora en fauna in het plangebied `De Waalsprong` in de Gemeente Nijmegen van de zomer van 2002 tot en met het voorjaar van 2003. Aangegeven worden de aanwezige en te verwachten soorten uit de Flora- en

  17. Assessment of Barotrauma Resulting from Rapid Decompression of Depth Acclimated Juvenile Chinook Salmon Bearing Radio Telemetry Transmitters

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Richard S.; Carlson, Thomas J.; Welch, Abigail E.; Stephenson, John R.; Abernethy, Cary S.; McKinstry, Craig A.; Theriault, Marie-Helene

    2007-09-06

    A multifactor study was conducted by Battelle for the US Army Corps of Engineers to assess the significance of the presence of a radio telemetry transmitter on the effects of rapid decompression from simulated hydro turbine passage on depth acclimated juvenile run-of-the-river Chinook salmon. Study factors were: (1) juvenile chinook salmon age;, subyearling or yearling, (2) radio transmitter present or absent, (3) three transmitter implantation factors: gastric, surgical, and no transmitter, and (4) four acclimation depth factors: 1, 10, 20, and 40 foot submergence equivalent absolute pressure, for a total of 48 unique treatments. Exposed fish were examined for changes in behavior, presence or absence of barotrauma injuries, and immediate or delayed mortality. Logistic models were used to test hypotheses that addressed study objectives. The presence of a radio transmitter was found to significantly increase the risk of barotrauma injury and mortality at exposure to rapid decompression. Gastric implantation was found to present a higher risk than surgical implantation. Fish were exposed within 48 hours of transmitter implantation so surgical incisions were not completely healed. The difference in results obtained for gastric and surgical implantation methods may be the result of study design and the results may have been different if tested fish had completely healed surgical wounds. However, the test did simulate the typical surgical-release time frame for in-river telemetry studies of fish survival so the results are probably representative for fish passing through a turbine shortly following release into the river. The finding of a significant difference in response to rapid decompression between fish bearing radio transmitters and those not implies a bias may exist in estimates of turbine passage survival obtained using radio telemetry. However, the rapid decompression (simulated turbine passage) conditions used for the study represented near worst case exposure

  18. Recovery time after intra-abdominal transmitter placement for telemetric (neuro)physiological measurement in freely moving common marmosets (Callitrix jacchus).

    NARCIS (Netherlands)

    Bakker, Jaco; Arndt, Saskia; Klomp, Rianne; Rijnbeek, Milene, W.M.; Philippens, Ingrid, H.C.H.M.; Langermans, Jan, A.

    2014-01-01

    Background Telemetry is very important for monitoring physiological functions in awake and freely moving laboratory animals. Although implantable transmitters reduce stress resulting from daily handling and restraint, the procedure requires invasive surgery, which affects behaviour and wellbeing of

  19. Real-time implementation of a 1.25-Gbit/s DMT transmitter for robust and low-cost LED-based plastic optical fiber applications

    NARCIS (Netherlands)

    Lee, S.C.J.; Breyer, F.; Cárdenas, D.; Randel, S.; Koonen, A.M.J.

    2009-01-01

    Real-time implementation of a DMT transmitter in FPGA is demonstrated for low-cost, standard 1-mm step-index plastic optical fiber applications based on commercial resonant-cavity LED and large-diameter (540 µm) photodiode.

  20. Transfusion transmittable infections - Seroprevalence among blood donors in a tertiary care hospital of Delhi

    Directory of Open Access Journals (Sweden)

    Sangeeta Pathak

    2013-01-01

    Full Text Available Context: Transfusion transmittable infections (TTI continue to be a major threat to safe transfusion practices. Blood is one of the major sources of transmission of infectious diseases viz. human immunodeficiency virus (HIV, hepatitis B virus (HBV, hepatitis C virus (HCV, syphilis, malaria, and many other infections in India. Screening assays for the infectious diseases with excellent sensitivity and specificity helps to enhance the safety of the blood transfusions reducing the diagnostic window period as much as possible. Aims: The present study was designed to determine the seroprevalence of TTIs viz., HIV, HCV, and HBV, among the blood donors in Max Super Specialty Hospital, New Delhi, India based on dual testing strategy using high sensitive screening assays such as enhanced chemiluminescence assay and nucleic acid testing (NAT. Materials and Methods: A total of 41207 blood units collected from the donors (both voluntary and replacement donors were screened for the TTI s, viz., anti HIV 1 and 2 antibody, anti HCV antibody, anti HBcore antibody, and HBsAg by enhanced chemiluminescence assay on VITROS ® ECiQ immunodiagnostics system. NAT was performed using Roche Cobas ® TaqScreen MPX assay, which can detect simultaneously HIV 1 (groups M and O, HIV-2, HCV, and HBV on Roche Cobas ® s201 system. Results: The seroprevalence of HIV, HBsAg, anti HBcore antibody, and HCV based on enhanced chemiluminescence assay was found to be 0.25, 0.2, 7.06, and 0.7%, respectively. A total number of 6587 samples from July 2010 to December 2010 were tested on NAT, of which 3 samples were reactive for HBV in NAT; this was missed by enhanced chemiluminescence assay. Conclusions: Based on the seroprevalence study of infectious diseases viz., HIV, HBV, and HCV, we conclude that screening of blood and blood components by dual testing strategy using high sensitivity serological assay like enhanced chemiluminescence technology and NAT helps in detecting the