WorldWideScience

Sample records for thermal reliability test

  1. Stand development and reliability tests of the thermal monitoring means for NPP

    International Nuclear Information System (INIS)

    Nalivaev, V.I.; Nikul'shin, V.S.; Kichigin, A.B.; Dirin, V.F.

    2003-01-01

    The paper is devoted to the reliability tests of thermoelectric thermometers and resistance thermometers during their operation in the nominal mode. Five stands Reliability are developed and operate for realization of tests of all manufactured thermal converters. delivered at NPP. Description of all stands are presented [ru

  2. Reliability of thermal interface materials: A review

    International Nuclear Information System (INIS)

    Due, Jens; Robinson, Anthony J.

    2013-01-01

    Thermal interface materials (TIMs) are used extensively to improve thermal conduction across two mating parts. They are particularly crucial in electronics thermal management since excessive junction-to-ambient thermal resistances can cause elevated temperatures which can negatively influence device performance and reliability. Of particular interest to electronic package designers is the thermal resistance of the TIM layer at the end of its design life. Estimations of this allow the package to be designed to perform adequately over its entire useful life. To this end, TIM reliability studies have been performed using accelerated stress tests. This paper reviews the body of work which has been performed on TIM reliability. It focuses on the various test methodologies with commentary on the results which have been obtained for the different TIM materials. Based on the information available in the open literature, a test procedure is proposed for TIM selection based on beginning and end of life performance. - Highlights: ► This paper reviews the body of work which has been performed on TIM reliability. ► Test methodologies for reliability testing are outlined. ► Reliability results for the different TIM materials are discussed. ► A test procedure is proposed for TIM selection BOLife and EOLife performance.

  3. Thermal reliability test of Al-34%Mg-6%Zn alloy as latent heat storage material and corrosion of metal with respect to thermal cycling

    International Nuclear Information System (INIS)

    Sun, J.Q.; Zhang, R.Y.; Liu, Z.P.; Lu, G.H.

    2007-01-01

    The purpose of this study is to determine the thermal reliability and corrosion of the Al-34%Mg-6%Zn alloy as a latent heat energy storage material with respect to various numbers of thermal cycles. The differential scanning calorimeter (DSC) analysis technique was applied to the alloy after 0, 50, 500 and 1000 melting/solidification cycles in order to measure the melting temperatures and the latent heats of fusion of the alloy. The containment materials were stainless steel (SS304L), carbon steel (steel C20) in the corrosion tests. The DSC results indicated that the change in melting temperature for the alloy was in the range of 3.06-5.3 K, and the latent heat of fusion decreased 10.98% after 1000 thermal cycles. The results show that the investigated Al-34%Mg-6%Zn alloy has a good thermal reliability as a latent heat energy storage material with respect to thermal cycling for thermal energy storage applications in the long term in view of the small changes in the latent heat of fusion and melting temperature. Gravimetric analysis as mass loss (mg/cm 2 ), corrosion rate (mg/day) and a microscopic or metallographic investigation were performed for corrosion tests and showed that SS304L may be considered a more suitable alloy than C20 in long term thermal storage applications

  4. Maximum thermal loading test of BWR fuel assembly

    International Nuclear Information System (INIS)

    Nakajima, Yoshitaka; Yoshimura, Kunihiro; Nakamura, Satoshi; Ishizuka, Takao.

    1987-01-01

    Various proving tests on the reliability of nuclear power plants have been conducted at the Nuclear Power Engineering Test Center and at the Japan Power Plant Engineering and Inspection Corporation. The tests were initiated at the request of the Ministry of International Trade and Industry (MITI). Toshiba undertook one of the proving tests on the reliability of nuclear fuel assembly; the maximum thermal loading test of BWR fuel assembly from the Nuclear Power Engineering Test Center. These tests are part of the proving tests mentioned above, and their purpose is to confirm the reliability of the thermal hydraulic engineering techniques. Toshiba has been engaged for the past nine years in the design, fabrication and testing of the equipment. For the project, a test model fuel assembly was used to measure the critical power of the BWR fuel assembly and the void and fluidity of the coolant. From the test results, it has been confirmed that the heat is transferred safely from the fuel assembly to the coolant in the BWR nuclear power plant. In addition, the propriety and reliability of the thermal hydraulic engineering techniques for the fuel assembly have been proved. (author)

  5. Eutectic mixtures of some fatty acids for latent heat storage: Thermal properties and thermal reliability with respect to thermal cycling

    International Nuclear Information System (INIS)

    Sari, Ahmet

    2006-01-01

    Accelerated thermal cycle tests have been conducted to study the change in melting temperatures and latent heats of fusion of the eutectic mixtures of lauric acid (LA)-myristic acid (MA), lauric acid (LA)-palmitic acid (PA) and myristic acid (MA)-stearic acid (SA) as latent heat storage materials. The thermal properties of these materials were determined by the differential scanning calorimetry (DSC) analysis method. The thermal reliability of the eutectic mixtures after melt/freeze cycles of 720, 1080 and 1460 was also evaluated using the DSC curves. The accelerated thermal cycle tests indicate that the melting temperatures usually tend to decrease, and the variations in the latent heats of fusion are irregular with increasing number of thermal cycles. Moreover, the probable reasons for the change in thermal properties of the eutectic mixtures after repeated thermal cycles were investigated. Fourier Transform Infrared (FT-IR) spectroscopic analysis indicates that the accelerated melt/freeze processes do not cause any degradation in the chemical structure of the mixtures. The change in thermal properties of the eutectic mixtures with increasing number of thermal cycles is only because of the presence of certain amounts of impurities in the fatty acids used in their preparation. It is concluded that the tested eutectic mixtures have reasonable thermal properties and thermal reliability as phase change materials (PCMs) for latent heat storage in any solar heating applications that include a four year utilization period

  6. Thermal Performance and Reliability Characterization of Bonded Interface Materials (BIMs): Preprint

    Energy Technology Data Exchange (ETDEWEB)

    DeVoto, D.; Paret, P.; Mihalic, M.; Narumanchi, S.; Bar-Cohen, A.; Matin, K.

    2014-08-01

    Thermal interface materials are an important enabler for low thermal resistance and reliable electronics packaging for a wide array of applications. There is a trend towards bonded interface materials (BIMs) because of their potential for low thermal resistivity (< 1 mm2K/W). However, BIMs induce thermomechanical stresses in the package and can be prone to failures and integrity risks. Deteriorated interfaces can result in high thermal resistance in the package and degradation and/or failure of the electronics. DARPA's Thermal Management Technologies program has addressed this challenge, supporting the development of mechanically-compliant, low resistivity nano-thermal interface (NTI) materials. In this work, we describe the testing procedure and report the results of NREL's thermal performance and reliability characterization of an initial sample of four different NTI-BIMs.

  7. Improving QST Reliability – More Raters, Tests or Occasions? A Multivariate Generalizability Study

    DEFF Research Database (Denmark)

    O'Neill, Søren; O'Neill, Lotte

    2015-01-01

    The reliability of quantitative sensory testing (QST) is affected by the error attributable to both test occasion and rater (examiner) as well as interactions between them. Most reliability studies only account for one source of error. The present study employed a fully-crossed, multivariate...... threshold, intensity, tolerance and modulation with mechanical, thermal and chemical stimuli. The classical test-retest and inter-rater reliability (0.19... procedures. Reliability was improved more by repeated testing on separate occasions opposed to repeated testing by different raters....

  8. MHTGR thermal performance envelopes: Reliability by design

    International Nuclear Information System (INIS)

    Etzel, K.T.; Howard, W.W.; Zgliczynski, J.B.

    1992-05-01

    This document discusses thermal performance envelopes which are used to specify steady-state design requirements for the systems of the Modular High Temperature Gas-Cooled Reactor to maximize plant performance reliability with optimized design. The thermal performance envelopes are constructed around the expected operating point accounting for uncertainties in actual plant as-built parameters and plant operation. The components are then designed to perform successfully at all points within the envelope. As a result, plant reliability is maximized by accounting for component thermal performance variation in the design. The design is optimized by providing a means to determine required margins in a disciplined and visible fashion

  9. A reliability model for interlayer dielectric cracking during fast thermal cycling

    NARCIS (Netherlands)

    Nguyen, Van Hieu; Salm, Cora; Krabbenborg, B.H.; Krabbenborg, B.H.; Bisschop, J.; Mouthaan, A.J.; Kuper, F.G.; Ray, Gary W.; Smy, Tom; Ohta, Tomohiro; Tsujimura, Manabu

    2003-01-01

    Interlayer dielectric (ILD) cracking can result in short circuits of multilevel interconnects. This paper presents a reliability model for ILD cracking induced by fast thermal cycling (FTC) stress. FTC tests have been performed under different temperature ranges (∆T) and minimum temperatures (Tmin).

  10. BWR 9 X 9 Fuel Assembly Thermal-Hydraulic Tests (2): Hydraulic Vibration Test

    International Nuclear Information System (INIS)

    Yoshiaki Tsukuda; Katsuichiro Kamimura; Toshiitsu Hattori; Akira Tanabe; Noboru Saito; Masahiko Warashina; Yuji Nishino

    2002-01-01

    Nuclear Power Engineering Corporation (NUPEC) conducted thermal-hydraulic projects for verification of thermal-hydraulic design reliability for BWR high-burnup 8 x 8 and 9 x 9 fuel assemblies, entrusted by the Ministry of Economy, Trade and Industry (METI). As a part of the NUPEC thermal-hydraulic projects, hydraulic vibration tests using full-scale test assemblies simulating 9 x 9 fuel assemblies were carried out to evaluate BWR fuel integrity. The test data were applied to development of a new correlation for the estimation of fuel rod vibration amplitude. (authors)

  11. Prediction of safety critical software operational reliability from test reliability using testing environment factors

    International Nuclear Information System (INIS)

    Jung, Hoan Sung; Seong, Poong Hyun

    1999-01-01

    It has been a critical issue to predict the safety critical software reliability in nuclear engineering area. For many years, many researches have focused on the quantification of software reliability and there have been many models developed to quantify software reliability. Most software reliability models estimate the reliability with the failure data collected during the test assuming that the test environments well represent the operation profile. User's interest is however on the operational reliability rather than on the test reliability. The experiences show that the operational reliability is higher than the test reliability. With the assumption that the difference in reliability results from the change of environment, from testing to operation, testing environment factors comprising the aging factor and the coverage factor are developed in this paper and used to predict the ultimate operational reliability with the failure data in testing phase. It is by incorporating test environments applied beyond the operational profile into testing environment factors. The application results show that the proposed method can estimate the operational reliability accurately. (Author). 14 refs., 1 tab., 1 fig

  12. A COMPUTERIZED DIAGNOSTIC COMPLEX FOR RELIABILITY TESTING OF ELECTRIC MACHINES

    Directory of Open Access Journals (Sweden)

    O.О. Somka

    2015-06-01

    Full Text Available Purpose. To develop a diagnostic complex meeting the criteria and requirements for carrying out accelerated reliability test and realizing the basic modes of electric machines operation and performance of the posed problems necessary in the process of such test. Methodology. To determine and forecast the indices of electric machines reliability in accordance with the statistic data of repair plants we have conditionally divided them into structural parts that are most likely to fail. We have preliminarily assessed the state of each of these parts, which includes revelation of faults and deviations of technical and geometric parameters. We have determined the analyzed electric machine controlled parameters used for assessment of quantitative characteristics of reliability of these parts and electric machines on the whole. Results. As a result of the research, we have substantiated the structure of a computerized complex for electric machines reliability test. It allows us to change thermal and vibration actions without violation of the physics of the processes of aging and wearing of the basic structural parts and elements material. The above mentioned makes it possible to considerably reduce time spent on carrying out electric machines reliability tests and improve trustworthiness of the data obtained as a result of their performance. Originality. A special feature of determination of the controlled parameters consists in removal of vibration components in the idle mode and after disconnection of the analyzed electric machine from the power supply with the aim of singling out the vibration electromagnetic component, fixing the degree of sparking and bend of the shaft by means of phototechnique and local determination of structural parts temperature provided by corresponding location of thermal sensors. Practical value. We have offered a scheme of location of thermal and vibration sensors, which allows improvement of parameters measuring accuracy

  13. Thermal performance envelopes for MHTGRs - Reliability by design

    International Nuclear Information System (INIS)

    Etzel, K.T.; Howard, W.W.; Zgliczynski, J.

    1992-01-01

    Thermal performance envelopes are used to specify steady-state design requirements for the systems of the modular high-temperature gas-cooled reactor (MHTGR) to maximize plant performance reliability with optimized design. The thermal performance envelopes are constructed around the expected operating point to account for uncertainties in actual plant as-built parameters and plant operation. The components are then designed to perform successfully at all points within the envelope. As a result, plant reliability is maximized by accounting for component thermal performance variation in the design. The design is optimized by providing a means to determine required margins in a disciplined and visible fashion. This is accomplished by coordinating these requirements with the various system and component designers in the early stages of the design, applying the principles of total quality management. The design is challenged by the more complex requirements associated with a range of operating conditions, but in return, high probability of delivering reliable performance throughout the plant life is ensured

  14. Performance reliability prediction for thermal aging based on kalman filtering

    International Nuclear Information System (INIS)

    Ren Shuhong; Wen Zhenhua; Xue Fei; Zhao Wensheng

    2015-01-01

    The performance reliability of the nuclear power plant main pipeline that failed due to thermal aging was studied by the performance degradation theory. Firstly, through the data obtained from the accelerated thermal aging experiments, the degradation process of the impact strength and fracture toughness of austenitic stainless steel material of the main pipeline was analyzed. The time-varying performance degradation model based on the state space method was built, and the performance trends were predicted by using Kalman filtering. Then, the multi-parameter and real-time performance reliability prediction model for the main pipeline thermal aging was developed by considering the correlation between the impact properties and fracture toughness, and by using the stochastic process theory. Thus, the thermal aging performance reliability and reliability life of the main pipeline with multi-parameter were obtained, which provides the scientific basis for the optimization management of the aging maintenance decision making for nuclear power plant main pipelines. (authors)

  15. Thermal properties and thermal reliability of eutectic mixtures of some fatty acids as latent heat storage materials

    International Nuclear Information System (INIS)

    Sari, Ahmet; Sari, Hayati; Oenal, Adem

    2004-01-01

    The present study deals with two subjects. The first one is to determine the thermal properties of lauric acid (LA)-stearic acid (SA), myristic acid (MA)-palmitic acid (PA) and palmitic acid (PA)-stearic acid (SA) eutectic mixtures as latent heat storage material. The properties were measured by the differential scanning calorimetry (DSC) analysis technique. The second one is to study the thermal reliability of these materials in view of the change in their melting temperatures and latent heats of fusion with respect to repeated thermal cycles. For this aim, the eutectic mixtures were subjected to 360 repeated melt/freeze cycles, and their thermal properties were measured after 0, 90,180 and 360 thermal cycles by the technique of DSC analysis. The DSC thermal analysis results show that the binary systems of LA-SA in the ratio of 75.5:24.5 wt.%, MA-PA in the ratio of 58:42 wt.% and PA-SA in the ratio of 64.2:35.8 wt.% form eutectic mixtures with melting temperatures of 37.0, 42.60 and 52.30 deg. C and with latent heats of fusion of 182.7, 169.7 and 181.7 J g -1 , respectively. These thermal properties make them possible for heat storage in passive solar heating applications with respect to climate conditions. The accelerated thermal cycle tests indicate that the changes in the melting temperatures and latent heats of fusion of the studied eutectic mixtures are not regular with increasing number of thermal cycles. However, these materials, latent heat energy storage materials, have good thermal reliability in terms of the change in their thermal properties with respect to thermal cycling for about a one year utility period

  16. Reliability evaluation of fiber optic sensors exposed to cyclic thermal load

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Heon Young; Kim, Dong Hoon [Advanced Materials Research Team, Korea Railroad Research Institute, Uiwang (Korea, Republic of); Kim, Dae Hyun [Dept. of Mechanical and Automotive Engineering, Seoul National University of Science and Technology, Seoul (Korea, Republic of)

    2016-06-15

    Fiber Bragg grating (FBG) sensors are currently the most prevalent sensors because of their unique advantages such as ease of multiplexing and capability of performing absolute measurements. They are applied to various structures for structural health monitoring (SHM). The signal characteristics of FBG sensors under thermal loading should be investigated to enhance the reliability of these sensors, because they are exposed to certain cyclic thermal loads due to temperature changes resulting from change of seasons, when they are applied to structures for SHM. In this study, tests on specimens are conducted in a thermal chamber with temperature changes from - to for 300 cycles. For the specimens, two types of base materials and adhesives that are normally used in the manufacture of packaged FBG sensors are selected. From the test results, it is confirmed that the FBG sensors undergo some degree of compressive strain under cyclic thermal load; this can lead to measurement errors. Hence, a pre-calibration is necessary before applying these sensors to structures for long-term SHM.

  17. Reliability test and failure analysis of high power LED packages

    International Nuclear Information System (INIS)

    Chen Zhaohui; Zhang Qin; Wang Kai; Luo Xiaobing; Liu Sheng

    2011-01-01

    A new type application specific light emitting diode (LED) package (ASLP) with freeform polycarbonate lens for street lighting is developed, whose manufacturing processes are compatible with a typical LED packaging process. The reliability test methods and failure criterions from different vendors are reviewed and compared. It is found that test methods and failure criterions are quite different. The rapid reliability assessment standards are urgently needed for the LED industry. 85 0 C/85 RH with 700 mA is used to test our LED modules with three other vendors for 1000 h, showing no visible degradation in optical performance for our modules, with two other vendors showing significant degradation. Some failure analysis methods such as C-SAM, Nano X-ray CT and optical microscope are used for LED packages. Some failure mechanisms such as delaminations and cracks are detected in the LED packages after the accelerated reliability testing. The finite element simulation method is helpful for the failure analysis and design of the reliability of the LED packaging. One example is used to show one currently used module in industry is vulnerable and may not easily pass the harsh thermal cycle testing. (semiconductor devices)

  18. thermal power stations' reliability evaluation in a hydrothermal system

    African Journals Online (AJOL)

    Dr Obe

    A quantitative tool for the evaluation of thermal power stations reliability in a hydrothermal system is presented. ... (solar power); wind (wind power) and the rest, thermal power and ... probability of a system performing its function adequately for ...

  19. Reliability Testing the Die-Attach of CPV Cell Assemblies

    Energy Technology Data Exchange (ETDEWEB)

    Bosco, N.; Sweet, C.; Kurtz, S.

    2011-02-01

    Results and progress are reported for a course of work to establish an efficient reliability test for the die-attach of CPV cell assemblies. Test vehicle design consists of a ~1 cm2 multijunction cell attached to a substrate via several processes. A thermal cycling sequence is developed in a test-to-failure protocol. Methods of detecting a failed or failing joint are prerequisite for this work; therefore both in-situ and non-destructive methods, including infrared imaging techniques, are being explored as a method to quickly detect non-ideal or failing bonds.

  20. Endurance of lead-free assembly under board level drop test and thermal cycling

    Energy Technology Data Exchange (ETDEWEB)

    Xia Yanghua [State Key Laboratory of Functional Materials for Informatics, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050 (China)], E-mail: xia_yanghua@hotmail.com; Xie Xiaoming [State Key Laboratory of Functional Materials for Informatics, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050 (China)

    2008-06-12

    The reliability of lead-free electronic assemblies under board level drop test and thermal cycling was investigated. TSOP (thin small outline package) devices with FeNi leads were reflow soldered on FR4 PCB (printed circuit board) with Sn3.0Ag0.5Cu (wt%) solder. The effects of different PCB finishes (organic solderability preservative (OSP) and electroless nickel immersion gold (ENIG)) on the reliability performance were studied. The results show that the assemblies with ENIG finishes reveal better reliability performance than its OSP counterparts under drop test, however, the OSP samples outperform those with ENIG finishes under thermal cycling. The failure mechanism is different under these two test conditions: the solder joints fracture into the intermetallic compounds (IMCs) layer under drop test, and cracks initiate in the bulk solder under thermal cycling. The surface finishes have an effect on the failure mode. The propagation of crack in the ENIG case is along the device/solder interface, while in the case of OSP, the crack extends parallel to the solder/PCB interface.

  1. Thermal Analysis of a SHIELD Electromigration Test Structure

    Energy Technology Data Exchange (ETDEWEB)

    Benson, David A.; Bowman, Duane J.; Mitchell, Robert T.

    1999-05-01

    The steady state and transient thermal behavior of an electromigration test structure was analyzed. The test structure was a Sandia SHIELD (Self-stressing HIgh fregquency rELiability Device) electromigration test device manufactured by an outside vendor. This device has a high frequency oscillator circuit, a buffer circuit to isolate and drive the metal line to the tested (DUT), the DUT to be electromigrated itself, a metal resistance thermometry monitor, and a heater elment to temperature accelerate the electromigration effect.

  2. Study and implementation of a thermal acceleration test for the improvement of the quality and reliability of components and systems; Estudo e implementacao de um teste de aceleracao termica para a melhoria da qualidade e confiabilidade de componentes e sistemas

    Energy Technology Data Exchange (ETDEWEB)

    Leao, Felippe Carneiro

    1993-09-01

    The objective of this work is to introduce the application of the burn-in test (test of thermal acceleration) in electronic products, using the practical example of this test in a power supply and to do an analysis of the application of this test in a production line showing the advantages and disadvantages of its implementation. For that it is made an abbreviation presentation of the basic concepts of quality and reliability. Starting from these concepts are presented the statistical models used in reliability, that describe the behavior of life of products and components. Besides showing, from the speed chemical reaction model , the influence of the temperature about this reliability.

  3. Thermal Protection for Mars Sample Return Earth Entry Vehicle: A Grand Challenge for Design Methodology and Reliability Verification

    Science.gov (United States)

    Venkatapathy, Ethiraj; Gage, Peter; Wright, Michael J.

    2017-01-01

    Mars Sample Return is our Grand Challenge for the coming decade. TPS (Thermal Protection System) nominal performance is not the key challenge. The main difficulty for designers is the need to verify unprecedented reliability for the entry system: current guidelines for prevention of backward contamination require that the probability of spores larger than 1 micron diameter escaping into the Earth environment be lower than 1 million for the entire system, and the allocation to TPS would be more stringent than that. For reference, the reliability allocation for Orion TPS is closer to 11000, and the demonstrated reliability for previous human Earth return systems was closer to 1100. Improving reliability by more than 3 orders of magnitude is a grand challenge indeed. The TPS community must embrace the possibility of new architectures that are focused on reliability above thermal performance and mass efficiency. MSR (Mars Sample Return) EEV (Earth Entry Vehicle) will be hit with MMOD (Micrometeoroid and Orbital Debris) prior to reentry. A chute-less aero-shell design which allows for self-righting shape was baselined in prior MSR studies, with the assumption that a passive system will maximize EEV robustness. Hence the aero-shell along with the TPS has to take ground impact and not break apart. System verification will require testing to establish ablative performance and thermal failure but also testing of damage from MMOD, and structural performance at ground impact. Mission requirements will demand analysis, testing and verification that are focused on establishing reliability of the design. In this proposed talk, we will focus on the grand challenge of MSR EEV TPS and the need for innovative approaches to address challenges in modeling, testing, manufacturing and verification.

  4. Enhancing thermal reliability of fiber-optic sensors for bio-inspired applications at ultra-high temperatures

    Science.gov (United States)

    Kang, Donghoon; Kim, Heon-Young; Kim, Dae-Hyun

    2014-07-01

    The rapid growth of bio-(inspired) sensors has led to an improvement in modern healthcare and human-robot systems in recent years. Higher levels of reliability and better flexibility, essential features of these sensors, are very much required in many application fields (e.g. applications at ultra-high temperatures). Fiber-optic sensors, and fiber Bragg grating (FBG) sensors in particular, are being widely studied as suitable sensors for improved structural health monitoring (SHM) due to their many merits. To enhance the thermal reliability of FBG sensors, thermal sensitivity, generally expressed as αf + ξf and considered a constant, should be investigated more precisely. For this purpose, the governing equation of FBG sensors is modified using differential derivatives between the wavelength shift and the temperature change in this study. Through a thermal test ranging from RT to 900 °C, the thermal sensitivity of FBG sensors is successfully examined and this guarantees thermal reliability of FBG sensors at ultra-high temperatures. In detail, αf + ξf has a non-linear dependence on temperature and varies from 6.0 × 10-6 °C-1 (20 °C) to 10.6 × 10-6 °C-1 (650 °C). Also, FBGs should be carefully used for applications at ultra-high temperatures due to signal disappearance near 900 °C.

  5. Proving test on the reliability for nuclear valves

    International Nuclear Information System (INIS)

    Kajiyama, Yasuo; Tashiro, Hisao; Uga, Takeo; Maeda, Shunichi.

    1986-01-01

    Since valves are the most common components, they could be the most frequent causes of troubles in nuclear power plants. This proving test, therefore, has an important meaning to examine and verify the reliability of various valves under simulating conditions of abnormal and transient operations of the nuclear power plant. The test was performed mainly for the various types and pressure ratings of valves which were used in the primary and secondary systems in BWR and PWR nuclear power plants and which had major operating or safety related functions in those nuclear power plants. The results of the proving test, confirmed for more than four years, showed relatively favourable performance of the tested valves. It is concluded that performances of valves including operability, seat sealing and structural integrity were proved under the thermal cycling, vibration and pipe reaction load conditions. Operating functions during and after accident such as loss of coolant accident were satisfactory. From these results, it was considered that the purpose of this proving test was satisfactorily fulfilled. Several data accumulated by the test would be useful to get better reliability if it was evaluated with the actually experienced data of valves in the nuclear power plants. (Nogami, K.)

  6. A study of operational and testing reliability in software reliability analysis

    International Nuclear Information System (INIS)

    Yang, B.; Xie, M.

    2000-01-01

    Software reliability is an important aspect of any complex equipment today. Software reliability is usually estimated based on reliability models such as nonhomogeneous Poisson process (NHPP) models. Software systems are improving in testing phase, while it normally does not change in operational phase. Depending on whether the reliability is to be predicted for testing phase or operation phase, different measure should be used. In this paper, two different reliability concepts, namely, the operational reliability and the testing reliability, are clarified and studied in detail. These concepts have been mixed up or even misused in some existing literature. Using different reliability concept will lead to different reliability values obtained and it will further lead to different reliability-based decisions made. The difference of the estimated reliabilities is studied and the effect on the optimal release time is investigated

  7. The FLIR ONE thermal imager for the assessment of burn wounds: Reliability and validity study.

    Science.gov (United States)

    Jaspers, M E H; Carrière, M E; Meij-de Vries, A; Klaessens, J H G M; van Zuijlen, P P M

    2017-11-01

    Objective measurement tools may be of great value to provide early and reliable burn wound assessment. Thermal imaging is an easy, accessible and objective technique, which measures skin temperature as an indicator of tissue perfusion. These thermal images might be helpful in the assessment of burn wounds. However, before implementation of a novel measurement tool into clinical practice is considered, it is appropriate to test its clinimetric properties (i.e. reliability and validity). The objective of this study was to assess the reliability and validity of the recently introduced FLIR ONE thermal imager. Two observers obtained thermal images of burn wounds in adult patients at day 1-3, 4-7 and 8-10 after burn. Subsequently, temperature differences between the burn wound and healthy skin (ΔT) were calculated on an iPad mini containing the FLIR Tools app. To assess reliability, ΔT values of both observers were compared by calculating the intraclass correlation coefficient (ICC) and measurement error parameters. To assess validity, the ΔT values of the first observer were compared to the registered healing time of the burn wounds, which was specified into three categories: (I) ≤14 days, (II) 15-21 days and (III) >21 days. The ability of the FLIR ONE to discriminate between healing ≤21 days and >21 days was evaluated by means of a receiver operating characteristic curve and an optimal ΔT cut-off value. Reliability: ICCs were 0.99 for each time point, indicating excellent reliability up to 10 days after burn. The standard error of measurement varied between 0.17-0.22°C. the area under the curve was calculated at 0.69 (95% CI 0.54-0.84). A cut-off value of -1.15°C shows a moderate discrimination between burn wound healing ≤21 days and >21 days (46% sensitivity; 82% specificity). Our results show that the FLIR ONE thermal imager is highly reliable, but the moderate validity calls for additional research. However, the FLIR ONE is pre-eminently feasible

  8. Enhancing thermal reliability of fiber-optic sensors for bio-inspired applications at ultra-high temperatures

    International Nuclear Information System (INIS)

    Kang, Donghoon; Kim, Heon-Young; Kim, Dae-Hyun

    2014-01-01

    The rapid growth of bio-(inspired) sensors has led to an improvement in modern healthcare and human–robot systems in recent years. Higher levels of reliability and better flexibility, essential features of these sensors, are very much required in many application fields (e.g. applications at ultra-high temperatures). Fiber-optic sensors, and fiber Bragg grating (FBG) sensors in particular, are being widely studied as suitable sensors for improved structural health monitoring (SHM) due to their many merits. To enhance the thermal reliability of FBG sensors, thermal sensitivity, generally expressed as α f + ξ f and considered a constant, should be investigated more precisely. For this purpose, the governing equation of FBG sensors is modified using differential derivatives between the wavelength shift and the temperature change in this study. Through a thermal test ranging from RT to 900 °C, the thermal sensitivity of FBG sensors is successfully examined and this guarantees thermal reliability of FBG sensors at ultra-high temperatures. In detail, α f + ξ f has a non-linear dependence on temperature and varies from 6.0 × 10 −6  °C −1 (20 °C) to 10.6 × 10 −6  °C −1 (650 °C). Also, FBGs should be carefully used for applications at ultra-high temperatures due to signal disappearance near 900 °C. (paper)

  9. Proof tests on reliability

    International Nuclear Information System (INIS)

    Mishima, Yoshitsugu

    1983-01-01

    In order to obtain public understanding on nuclear power plants, tests should be carried out to prove the reliability and safety of present LWR plants. For example, the aseismicity of nuclear power plants must be verified by using a large scale earthquake simulator. Reliability test began in fiscal 1975, and the proof tests on steam generators and on PWR support and flexure pins against stress corrosion cracking have already been completed, and the results have been internationally highly appreciated. The capacity factor of the nuclear power plant operation in Japan rose to 80% in the summer of 1983, and considering the period of regular inspection, it means the operation of almost full capacity. Japanese LWR technology has now risen to the top place in the world after having overcome the defects. The significance of the reliability test is to secure the functioning till the age limit is reached, to confirm the correct forecast of deteriorating process, to confirm the effectiveness of the remedy to defects and to confirm the accuracy of predicting the behavior of facilities. The reliability of nuclear valves, fuel assemblies, the heat affected zones in welding, reactor cooling pumps and electric instruments has been tested or is being tested. (Kako, I.)

  10. Test-retest Agreement and Reliability of Quantitative Sensory Testing 1 Year After Breast Cancer Surgery

    DEFF Research Database (Denmark)

    Andersen, Kenneth Geving; Kehlet, Henrik; Aasvang, Eske Kvanner

    2015-01-01

    .5 SD) than within-patient variation (0.23 to 3.55 SD). There were no significant differences between pain and pain-free patients. The individual test-retest variability was higher on the operated side compared with the nonoperated side. DISCUSSION: The QST protocol reliability allows for group......OBJECTIVES: Quantitative sensory testing (QST) is used to assess sensory dysfunction and nerve damage by examining psychophysical responses to controlled, graded stimuli such as mechanical and thermal detection and pain thresholds. In the breast cancer population, 4 studies have used QST to examine...... persistent pain after breast cancer treatment, suggesting neuropathic pain being a prominent pain mechanism. However, the agreement and reliability of QST has not been described in the postsurgical breast cancer population, hindering exact interpretation of QST studies in this population. The aim...

  11. Thermal Management and Reliability of Power Electronics and Electric Machines

    Energy Technology Data Exchange (ETDEWEB)

    Narumanchi, Sreekant

    2016-06-13

    Increasing the number of electric-drive vehicles (EDVs) on America's roads has been identified as a strategy with near-term potential for dramatically decreasing the nation's dependence on oil - by the U.S. Department of Energy, the federal cross-agency EV-Everywhere Challenge, and the automotive industry. Mass-market deployment will rely on meeting aggressive technical targets, including improved efficiency and reduced size, weight, and cost. Many of these advances will depend on optimization of thermal management. Effective thermal management is critical to improving the performance and ensuring the reliability of EDVs. Efficient heat removal makes higher power densities and lower operating temperatures possible, and in turn enables cost and size reductions. The National Renewable Energy Laboratory (NREL), along with DOE and industry partners is working to develop cost-effective thermal management solutions to increase device and component power densities. In this presentation, the activities in recent years related to thermal management and reliability of automotive power electronics and electric machines are presented.

  12. Test design requirements: Thermal conductivity probe testing

    International Nuclear Information System (INIS)

    Heath, R.E.

    1985-01-01

    This document establishes the test design requirements for development of a thermal conductivity probe test. The thermal conductivity probe determines in situ thermal conductivity using a line source transient heat conduction analysis. This document presents the rationale for thermal conductivity measurement using a thermal conductivity probe. A general test description is included. Support requirements along with design constraints are detailed to allow simple design of the thermal conductivity probe and test. The schedule and delivery requirements of the responsible test designer are also included. 7 refs., 1 fig

  13. Development of thermal hydraulic models for the reliable regulatory auditing code

    Energy Technology Data Exchange (ETDEWEB)

    Chung, B. D.; Song, C. H.; Lee, Y. J.; Kwon, T. S.; Lee, S. W. [Korea Automic Energy Research Institute, Taejon (Korea, Republic of)

    2004-02-15

    The objective of this project is to develop thermal hydraulic models for use in improving the reliability of the regulatory auditing codes. The current year fall under the second step of the 3 year project, and the main researches were focused on the development of downcorner boiling model. During the current year, the bubble stream model of downcorner has been developed and installed in he auditing code. The model sensitivity analysis has been performed for APR1400 LBLOCA scenario using the modified code. The preliminary calculation has been performed for the experimental test facility using FLUENT and MARS code. The facility for air bubble experiment has been installed. The thermal hydraulic phenomena for VHTR and super critical reactor have been identified for the future application and model development.

  14. Test Reliability at the Individual Level

    Science.gov (United States)

    Hu, Yueqin; Nesselroade, John R.; Erbacher, Monica K.; Boker, Steven M.; Burt, S. Alexandra; Keel, Pamela K.; Neale, Michael C.; Sisk, Cheryl L.; Klump, Kelly

    2016-01-01

    Reliability has a long history as one of the key psychometric properties of a test. However, a given test might not measure people equally reliably. Test scores from some individuals may have considerably greater error than others. This study proposed two approaches using intraindividual variation to estimate test reliability for each person. A simulation study suggested that the parallel tests approach and the structural equation modeling approach recovered the simulated reliability coefficients. Then in an empirical study, where forty-five females were measured daily on the Positive and Negative Affect Schedule (PANAS) for 45 consecutive days, separate estimates of reliability were generated for each person. Results showed that reliability estimates of the PANAS varied substantially from person to person. The methods provided in this article apply to tests measuring changeable attributes and require repeated measures across time on each individual. This article also provides a set of parallel forms of PANAS. PMID:28936107

  15. Test-re-test reliability and inter-rater reliability of a digital pelvic inclinometer in young, healthy males and females.

    Science.gov (United States)

    Beardsley, Chris; Egerton, Tim; Skinner, Brendon

    2016-01-01

    Objective. The purpose of this study was to investigate the reliability of a digital pelvic inclinometer (DPI) for measuring sagittal plane pelvic tilt in 18 young, healthy males and females. Method. The inter-rater reliability and test-re-test reliabilities of the DPI for measuring pelvic tilt in standing on both the right and left sides of the pelvis were measured by two raters carrying out two rating sessions of the same subjects, three weeks apart. Results. For measuring pelvic tilt, inter-rater reliability was designated as good on both sides (ICC = 0.81-0.88), test-re-test reliability within a single rating session was designated as good on both sides (ICC = 0.88-0.95), and test-re-test reliability between two rating sessions was designated as moderate on the left side (ICC = 0.65) and good on the right side (ICC = 0.85). Conclusion. Inter-rater reliability and test-re-test reliability within a single rating session of the DPI in measuring pelvic tilt were both good, while test-re-test reliability between rating sessions was moderate-to-good. Caution is required regarding the interpretation of the test-re-test reliability within a single rating session, as the raters were not blinded. Further research is required to establish validity.

  16. Thermal Management and Reliability of Automotive Power Electronics and Electric Machines

    Energy Technology Data Exchange (ETDEWEB)

    Narumanchi, Sreekant V [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Bennion, Kevin S [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Cousineau, Justine E [National Renewable Energy Laboratory (NREL), Golden, CO (United States); DeVoto, Douglas J [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Feng, Xuhui [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Kekelia, Bidzina [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Kozak, Joseph P [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Major, Joshua [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Moreno, Gilberto [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Paret, Paul P [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Tomerlin, Jeff J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2018-02-09

    Low-cost, high-performance thermal management technologies are helping meet aggressive power density, specific power, cost, and reliability targets for power electronics and electric machines. The National Renewable Energy Laboratory is working closely with numerous industry and research partners to help influence development of components that meet aggressive performance and cost targets through development and characterization of cooling technologies, and thermal characterization and improvements of passive stack materials and interfaces. Thermomechanical reliability and lifetime estimation models are important enablers for industry in cost-and time-effective design.

  17. Apollo telescope mount thermal systems unit thermal vacuum test

    Science.gov (United States)

    Trucks, H. F.; Hueter, U.; Wise, J. H.; Bachtel, F. D.

    1971-01-01

    The Apollo Telescope Mount's thermal systems unit was utilized to conduct a full-scale thermal vacuum test to verify the thermal design and the analytical techniques used to develop the thermal mathematical models. Thermal vacuum test philosophy, test objectives configuration, test monitoring, environment simulation, vehicle test performance, and data correlation are discussed. Emphasis is placed on planning and execution of the thermal vacuum test with particular attention on problems encountered in conducting a test of this maguitude.

  18. Thermal Management and Reliability of Power Electronics and Electric Machines

    Energy Technology Data Exchange (ETDEWEB)

    Narumanchi, Sreekant

    2016-08-03

    Increasing the number of electric-drive vehicles (EDVs) on America's roads has been identified as a strategy with near-term potential for dramatically decreasing the nation's dependence on oil -- by the U.S. Department of Energy, the federal cross-agency EV-Everywhere Challenge, and the automotive industry. Mass-market deployment will rely on meeting aggressive technical targets, including improved efficiency and reduced size, weight, and cost. Many of these advances will depend on optimization of thermal management. Effective thermal management is critical to improving the performance and ensuring the reliability of EDVs. Efficient heat removal makes higher power densities and lower operating temperatures possible, and in turn enables cost and size reductions. The National Renewable Energy Laboratory (NREL), along with DOE and industry partners is working to develop cost-effective thermal management solutions to increase device and component power densities. In this presentation, the activities in recent years related to thermal management and reliability of automotive power electronics and electric machines will be presented.

  19. Benchmark testing of CENDL-2 for U-fuel thermal reactors

    International Nuclear Information System (INIS)

    Zhang Baocheng; Liu Guisheng; Liu Ping

    1995-01-01

    Based on CENDL-2, NJOY-WIMS code system was used to generate 69-group constants, and do benchmark testing for TRX-1,2; BAPL-UO-2-1,2,3; ZEEP-1,2,3. All the results proved that CENDL-2 is reliable for thermal reactor calculations. (3 tabs.)

  20. Prediction of software operational reliability using testing environment factors

    International Nuclear Information System (INIS)

    Jung, Hoan Sung; Seong, Poong Hyun

    1995-01-01

    A number of software reliability models have been developed to estimate and to predict software reliability. However, there are no established standard models to quantify software reliability. Most models estimate the quality of software in reliability figures such as remaining faults, failure rate, or mean time to next failure at the testing phase, and they consider them ultimate indicators of software reliability. Experience shows that there is a large gap between predicted reliability during development and reliability measured during operation, which means that predicted reliability, or so-called test reliability, is not operational reliability. Customers prefer operational reliability to test reliability. In this study, we propose a method that predicts operational reliability rather than test reliability by introducing the testing environment factor that quantifies the changes in environments

  1. Test-retest reliability of cognitive EEG

    Science.gov (United States)

    McEvoy, L. K.; Smith, M. E.; Gevins, A.

    2000-01-01

    OBJECTIVE: Task-related EEG is sensitive to changes in cognitive state produced by increased task difficulty and by transient impairment. If task-related EEG has high test-retest reliability, it could be used as part of a clinical test to assess changes in cognitive function. The aim of this study was to determine the reliability of the EEG recorded during the performance of a working memory (WM) task and a psychomotor vigilance task (PVT). METHODS: EEG was recorded while subjects rested quietly and while they performed the tasks. Within session (test-retest interval of approximately 1 h) and between session (test-retest interval of approximately 7 days) reliability was calculated for four EEG components: frontal midline theta at Fz, posterior theta at Pz, and slow and fast alpha at Pz. RESULTS: Task-related EEG was highly reliable within and between sessions (r0.9 for all components in WM task, and r0.8 for all components in the PVT). Resting EEG also showed high reliability, although the magnitude of the correlation was somewhat smaller than that of the task-related EEG (r0.7 for all 4 components). CONCLUSIONS: These results suggest that under appropriate conditions, task-related EEG has sufficient retest reliability for use in assessing clinical changes in cognitive status.

  2. Thermal System Upgrade of the Space Environment Simulation Test Chamber

    Science.gov (United States)

    Desai, Ashok B.

    1997-01-01

    The paper deals with the refurbishing and upgrade of the thermal system for the existing thermal vacuum test facility, the Space Environment Simulator, at NASA's Goddard Space Flight Center. The chamber is the largest such facility at the center. This upgrade is the third phase of the long range upgrade of the chamber that has been underway for last few years. The first phase dealt with its vacuum system, the second phase involved the GHe subsystem. The paper describes the considerations of design philosophy options for the thermal system; approaches taken and methodology applied, in the evaluation of the remaining "life" in the chamber shrouds and related equipment by conducting special tests and studies; feasibility and extent of automation, using computer interfaces and Programmable Logic Controllers in the control system and finally, matching the old components to the new ones into an integrated, highly reliable and cost effective thermal system for the facility. This is a multi-year project just started and the paper deals mainly with the plans and approaches to implement the project successfully within schedule and costs.

  3. A standard for test reliability in group research.

    Science.gov (United States)

    Ellis, Jules L

    2013-03-01

    Many authors adhere to the rule that test reliabilities should be at least .70 or .80 in group research. This article introduces a new standard according to which reliabilities can be evaluated. This standard is based on the costs or time of the experiment and of administering the test. For example, if test administration costs are 7 % of the total experimental costs, the efficient value of the reliability is .93. If the actual reliability of a test is equal to this efficient reliability, the test size maximizes the statistical power of the experiment, given the costs. As a standard in experimental research, it is proposed that the reliability of the dependent variable be close to the efficient reliability. Adhering to this standard will enhance the statistical power and reduce the costs of experiments.

  4. Developing MESA : an accelerated reliability test

    NARCIS (Netherlands)

    Baskoro, G.; Rouvroye, J.L.; Bacher, W.; Brombacher, A.C.

    2003-01-01

    This paper describes the on-going research on an accelerated reliability test strategy called MESA (Multiple Environment Stress Analysis) intended to find in a fast and efficient manner (potential) reliability problems during the design phase of high volume consumer products. This test has shown

  5. Prediction of software operational reliability using testing environment factors

    International Nuclear Information System (INIS)

    Jung, Hoan Sung; Seong, Poong Hyun

    1995-01-01

    For many years, many researches have focused on the quantification of software reliability and there are many models developed to quantify software reliability. Most software reliability models estimate the reliability with the failure data collected during the test assuming that the test environments well represent the operation profile. The experiences show that the operational reliability is higher than the test reliability User's interest is on the operational reliability rather than on the test reliability, however. With the assumption that the difference in reliability results from the change of environment, testing environment factors comprising the aging factor and the coverage factor are defined in this study to predict the ultimate operational reliability with the failure data. It is by incorporating test environments applied beyond the operational profile into testing environment factors. The application results are close to the actual data

  6. Reliability of provocative tests of motion sickness susceptibility

    Science.gov (United States)

    Calkins, D. S.; Reschke, M. F.; Kennedy, R. S.; Dunlop, W. P.

    1987-01-01

    Test-retest reliability values were derived from motion sickness susceptibility scores obtained from two successive exposures to each of three tests: (1) Coriolis sickness sensitivity test; (2) staircase velocity movement test; and (3) parabolic flight static chair test. The reliability of the three tests ranged from 0.70 to 0.88. Normalizing values from predictors with skewed distributions improved the reliability.

  7. Prediction of software operational reliability using testing environment factor

    International Nuclear Information System (INIS)

    Jung, Hoan Sung

    1995-02-01

    Software reliability is especially important to customers these days. The need to quantify software reliability of safety-critical systems has been received very special attention and the reliability is rated as one of software's most important attributes. Since the software is an intellectual product of human activity and since it is logically complex, the failures are inevitable. No standard models have been established to prove the correctness and to estimate the reliability of software systems by analysis and/or testing. For many years, many researches have focused on the quantification of software reliability and there are many models developed to quantify software reliability. Most software reliability models estimate the reliability with the failure data collected during the test assuming that the test environments well represent the operation profile. User's interest is on the operational reliability rather than on the test reliability, however. The experiences show that the operational reliability is higher than the test reliability. With the assumption that the difference in reliability results from the change of environment, testing environment factor comprising the aging factor and the coverage factor are defined in this work to predict the ultimate operational reliability with the failure data. It is by incorporating test environments applied beyond the operational profile into testing environment factor Test reliability can also be estimated with this approach without any model change. The application results are close to the actual data. The approach used in this thesis is expected to be applicable to ultra high reliable software systems that are used in nuclear power plants, airplanes, and other safety-critical applications

  8. CPM Test-Retest Reliability: "Standard" vs "Single Test-Stimulus" Protocols.

    Science.gov (United States)

    Granovsky, Yelena; Miller-Barmak, Adi; Goldstein, Oren; Sprecher, Elliot; Yarnitsky, David

    2016-03-01

    Assessment of pain inhibitory mechanisms using conditioned pain modulation (CPM) is relevant clinically in prediction of pain and analgesic efficacy. Our objective is to provide necessary estimates of intersession CPM reliability, to enable transformation of the CPM paradigm into a clinical tool. Two cohorts of young healthy subjects (N = 65) participated in two dual-session studies. In Study I, a Bath-Thermode CPM protocol was used, with hot water immersion and contact heat as conditioning- and test-stimuli, respectively, in a classical parallel CPM design introducing test-stimulus first, and then the conditioning- and repeated test-stimuli in parallel. Study II consisted of two CPM protocols: 1) Two-Thermodes, one for each of the stimuli, in the same parallel design as above, and 2) single test-stimulus (STS) protocol with a single administration of a contact heat test-stimulus, partially overlapped in time by a remote shorter contact heat as conditioning stimulus. Test-retest reliability was assessed within 3-7 days. The STS-CPM had superior reliability intraclass correlation (ICC 2 ,: 1  = 0.59) over Bath-Thermode (ICC 2 ,: 1  = 0.34) or Two-Thermodes (ICC 2 ,: 1  = 0.21) protocols. The hand immersion conditioning pain had higher reliability than thermode pain (ICC 2 ,: 1  = 0.76 vs ICC 2 ,: 1  = 0.16). Conditioned test-stimulus pain scores were of good (ICC 2 ,: 1  = 0.62) or fair (ICC 2 ,: 1  = 0.43) reliability for the Bath-Thermode and the STS, respectively, but not for the Two-Thermodes protocol (ICC 2 ,: 1  = 0.20). The newly developed STS-CPM paradigm was more reliable than other CPM protocols tested here, and should be further investigated for its clinical relevance. It appears that large contact size of the conditioning-stimulus and use of single rather than dual test-stimulus pain contribute to augmentation of CPM reliability. © 2015 American Academy of Pain Medicine. All rights reserved. For permissions, please e

  9. Preparation, thermal properties and thermal reliabilities of microencapsulated n-octadecane with acrylic-based polymer shells for thermal energy storage

    International Nuclear Information System (INIS)

    Qiu, Xiaolin; Song, Guolin; Chu, Xiaodong; Li, Xuezhu; Tang, Guoyi

    2013-01-01

    Highlights: ► n-Octadecane was encapsulated by p(butyl methacrylate) (PBMA) and p(butyl acrylate). ► Microcapsules using divinylbenzene as crosslinking agent have better quality. ► Microcapsule with butyl methacrylate–divinylbenzene has highest latent heat. ► Microcapsule with butyl methacrylate–divinylbenzene has greatest thermal stability. ► Phase change temperatures and enthalpies of the microcapsules varied little after thermal cycle. - Abstract: Microencapsulation of n-octadecane with crosslinked p(butyl methacrylate) (PBMA) and p(butyl acrylate) (PBA) as shells for thermal energy storage was carried out by a suspension-like polymerization. Divinylbenzene (DVB) and pentaerythritol triacrylate (PETA) were employed as crosslinking agents. The surface morphologies of the microencapsulated phase change materials (microPCMs) were studied by scanning electron microscopy (SEM). Thermal properties, thermal reliabilities and thermal stabilities of the as-prepared microPCMs were investigated by differential scanning calorimetry (DSC) and thermal gravimetric analysis (TGA). The microPCMs prepared by using DVB exhibit greater heat capacities and higher thermal stabilities compared with those prepared by using PETA. The thermal resistant temperature of the microPCM with BMA–DVB polymer was up to 248 °C. The phase change temperatures and latent heats of all the as-prepared microcapsules varied little after 1000 thermal cycles.

  10. Reliability of two social cognition tests: The combined stories test and the social knowledge test.

    Science.gov (United States)

    Thibaudeau, Élisabeth; Cellard, Caroline; Legendre, Maxime; Villeneuve, Karèle; Achim, Amélie M

    2018-04-01

    Deficits in social cognition are common in psychiatric disorders. Validated social cognition measures with good psychometric properties are necessary to assess and target social cognitive deficits. Two recent social cognition tests, the Combined Stories Test (COST) and the Social Knowledge Test (SKT), respectively assess theory of mind and social knowledge. Previous studies have shown good psychometric properties for these tests, but the test-retest reliability has never been documented. The aim of this study was to evaluate the test-retest reliability and the inter-rater reliability of the COST and the SKT. The COST and the SKT were administered twice to a group of forty-two healthy adults, with a delay of approximately four weeks between the assessments. Excellent test-retest reliability was observed for the COST, and a good test-retest reliability was observed for the SKT. There was no evidence of practice effect. Furthermore, an excellent inter-rater reliability was observed for both tests. This study shows a good reliability of the COST and the SKT that adds to the good validity previously reported for these two tests. These good psychometrics properties thus support that the COST and the SKT are adequate measures for the assessment of social cognition. Copyright © 2018. Published by Elsevier B.V.

  11. Evaluation of Defects of Thermal Barrier Coatings by Thermal Shock Test Using Eddy Current Testing

    Energy Technology Data Exchange (ETDEWEB)

    Heo, Tae Hoon; Cho, Youn Ho; Lee, Joon Hyun [Pusan National University, Busan (Korea, Republic of); Oh, Jeong Seok; Lee, Koo Hyun [KIMM, Daejeon (Korea, Republic of)

    2009-10-15

    Periodical thermal shock can introduce defects in thermal barrier coating made by layers of CoNiCrAlY bond coating(BC) and ZrO{sub 2}-8wt%Y{sub 2}O{sub 3} ceramic top coating(TC) on Inconel-738 substrate using plasma spraying. Thermal shock test is performed by severe condition that is to heat until 1000 .deg. C and cool until 20 .deg. C. As the number of cycle is increased, the fatigue by thermal shock is also increased. After test, the micro-structures and mechanical characteristics of thermal barrier coating were investigated by SEM, XRD. The TGO layer of is Al{sub 2}O{sub 3} formed between BC and TC by periodical thermal shock test, and its change in thickness is inspected by eddy current test(ECT). By ECT test, it is shown that TGO and micro-crack can be detected and it is possible to predict the life of thermal barrier coating

  12. Reliability and Lifetime Prediction of Remote Phosphor Plates in Solid-State Lighting Applications Using Accelerated Degradation Testing

    NARCIS (Netherlands)

    Yazdan Mehr, M.; van Driel, W.D.; Zhang, G.Q.

    2015-01-01

    A methodology, based on accelerated degradation testing, is developed to predict the lifetime of remote phosphor plates used in solid-state lighting (SSL) applications. Both thermal stress and light intensity are used to accelerate degradation reaction in remote phosphor plates. A reliability model,

  13. Preparation, thermal properties and thermal reliabilities of microencapsulated n-octadecane with acrylic-based polymer shells for thermal energy storage

    Energy Technology Data Exchange (ETDEWEB)

    Qiu, Xiaolin [Advanced Materials Institute and Clearer Production Key Laboratory, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055 (China); Key Laboratory of Advanced Materials, Department of Materials Science and Engineering, Tsinghua University, Haidian District, Beijing 100084 (China); Song, Guolin; Chu, Xiaodong; Li, Xuezhu [Advanced Materials Institute and Clearer Production Key Laboratory, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055 (China); Tang, Guoyi, E-mail: tanggy@tsinghua.edu.cn [Advanced Materials Institute and Clearer Production Key Laboratory, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055 (China); Key Laboratory of Advanced Materials, Department of Materials Science and Engineering, Tsinghua University, Haidian District, Beijing 100084 (China)

    2013-01-10

    Highlights: Black-Right-Pointing-Pointer n-Octadecane was encapsulated by p(butyl methacrylate) (PBMA) and p(butyl acrylate). Black-Right-Pointing-Pointer Microcapsules using divinylbenzene as crosslinking agent have better quality. Black-Right-Pointing-Pointer Microcapsule with butyl methacrylate-divinylbenzene has highest latent heat. Black-Right-Pointing-Pointer Microcapsule with butyl methacrylate-divinylbenzene has greatest thermal stability. Black-Right-Pointing-Pointer Phase change temperatures and enthalpies of the microcapsules varied little after thermal cycle. - Abstract: Microencapsulation of n-octadecane with crosslinked p(butyl methacrylate) (PBMA) and p(butyl acrylate) (PBA) as shells for thermal energy storage was carried out by a suspension-like polymerization. Divinylbenzene (DVB) and pentaerythritol triacrylate (PETA) were employed as crosslinking agents. The surface morphologies of the microencapsulated phase change materials (microPCMs) were studied by scanning electron microscopy (SEM). Thermal properties, thermal reliabilities and thermal stabilities of the as-prepared microPCMs were investigated by differential scanning calorimetry (DSC) and thermal gravimetric analysis (TGA). The microPCMs prepared by using DVB exhibit greater heat capacities and higher thermal stabilities compared with those prepared by using PETA. The thermal resistant temperature of the microPCM with BMA-DVB polymer was up to 248 Degree-Sign C. The phase change temperatures and latent heats of all the as-prepared microcapsules varied little after 1000 thermal cycles.

  14. Thermal Hydraulic Tests for Reactor Core Safety

    Energy Technology Data Exchange (ETDEWEB)

    Moon, S. K.; Baek, W. P.; Chun, S. Y. (and others)

    2007-06-15

    The main objectives of the present project are to resolve the current issues of reactor core thermal hydraulics, to develop an advanced measurement and analytical techniques, and to perform reactor core safety verification tests. 6x6 reflood experiments, various heat transfer experiments using Freon, and experiments on the spacer grids effects on the post-dryout are carried out using spacer grids developed in Korea in order to resolve the current issues of the reactor core thermal hydraulics. In order to develop a reflood heat transfer model, the detailed reflood phenomena are visualized and measured using round tube and 2x2 rod bundle. A detailed turbulent mixing phenomenon for subchannels is measured using advanced measurement techniques such as LDV and PIV. MARS and MATRA codes developed in Korea are assessed, verified and improved using the obtained experimental data. Finally, a systematic quality assurance program and experimental data generation system has been constructed in order to increase the reliability of the experimental data.

  15. Thermal test options

    International Nuclear Information System (INIS)

    Koski, J.A.; Keltner, N.R.; Sobolik, K.B.

    1993-02-01

    Shipping containers for radioactive materials must be qualified to meet a thermal accident environment specified in regulations, such at Title 10, Code of Federal Regulations, Part 71. Aimed primarily at the shipping container design, this report discusses the thermal testing options available for meeting the regulatory requirements, and states the advantages and disadvantages of each approach. The principal options considered are testing with radiant heat, furnaces, and open pool fires. The report also identifies some of the facilities available and current contacts. Finally, the report makes some recommendations on the appropriate use of these different testing methods

  16. Simulation and test of the thermal behavior of pressure switch

    Science.gov (United States)

    Liu, Yifang; Chen, Daner; Zhang, Yao; Dai, Tingting

    2018-04-01

    Little, lightweight, low-power microelectromechanical system (MEMS) pressure switches offer a good development prospect for small, ultra-long, simple atmosphere environments. In order to realize MEMS pressure switch, it is necessary to solve one of the key technologies such as thermal robust optimization. The finite element simulation software is used to analyze the thermal behavior of the pressure switch and the deformation law of the pressure switch film under different temperature. The thermal stress releasing schemes are studied by changing the structure of fixed form and changing the thickness of the substrate, respectively. Finally, the design of the glass substrate thickness of 2.5 mm is used to ensure that the maximum equivalent stress is reduced to a quarter of the original value, only 154 MPa when the structure is in extreme temperature (80∘C). The test results show that after the pressure switch is thermally optimized, the upper and lower electrodes can be reliably contacted to accommodate different operating temperature environments.

  17. Thermal Testing Measurements Report

    Energy Technology Data Exchange (ETDEWEB)

    R. Wagner

    2002-09-26

    The purpose of the Thermal Testing Measurements Report (Scientific Analysis Report) is to document, in one report, the comprehensive set of measurements taken within the Yucca Mountain Project Thermal Testing Program since its inception in 1996. Currently, the testing performed and measurements collected are either scattered in many level 3 and level 4 milestone reports or, in the case of the ongoing Drift Scale Test, mostly documented in eight informal progress reports. Documentation in existing reports is uneven in level of detail and quality. Furthermore, while all the data collected within the Yucca Mountain Site Characterization Project (YMP) Thermal Testing Program have been submitted periodically to the Technical Data Management System (TDMS), the data structure--several incremental submittals, and documentation formats--are such that the data are often not user-friendly except to those who acquired and processed the data. The documentation in this report is intended to make data collected within the YMP Thermal Testing Program readily usable to end users, such as those representing the Performance Assessment Project, Repository Design Project, and Engineered Systems Sub-Project. Since either detailed level 3 and level 4 reports exist or the measurements are straightforward, only brief discussions are provided for each data set. These brief discussions for different data sets are intended to impart a clear sense of applicability of data, so that they will be used properly within the context of measurement uncertainty. This approach also keeps this report to a manageable size, an important consideration because the report encompasses nearly all measurements for three long-term thermal tests. As appropriate, thermal testing data currently residing in the TDMS have been reorganized and reformatted from cumbersome, user-unfriendly Input-Data Tracking Numbers (DTNs) into a new set of Output-DTNs. These Output-DTNs provide a readily usable data structure

  18. Thermal Cycling and High Temperature Reverse Bias Testing of Control and Irradiated Gallium Nitride Power Transistors

    Science.gov (United States)

    Patterson, Richard L.; Boomer, Kristen T.; Scheick, Leif; Lauenstein, Jean-Marie; Casey, Megan; Hammoud, Ahmad

    2014-01-01

    The power systems for use in NASA space missions must work reliably under harsh conditions including radiation, thermal cycling, and exposure to extreme temperatures. Gallium nitride semiconductors show great promise, but information pertaining to their performance is scarce. Gallium nitride N-channel enhancement-mode field effect transistors made by EPC Corporation in a 2nd generation of manufacturing were exposed to radiation followed by long-term thermal cycling and testing under high temperature reverse bias conditions in order to address their reliability for use in space missions. Result of the experimental work are presented and discussed.

  19. OPTIMUM DESIGN OF EXPERIMENTS FOR ACCELERATED RELIABILITY TESTING

    Directory of Open Access Journals (Sweden)

    Sebastian Marian ZAHARIA

    2014-05-01

    Full Text Available In this paper is presented a case study that demonstrates how design to experiments (DOE information can be used to design better accelerated reliability tests. In the case study described in this paper, will be done a comparison and optimization between main accelerated reliability test plans (3 Level Best Standard Plan, 3 Level Best Compromise Plan, 3 Level Best Equal Expected Number Failing Plan, 3 Level 4:2:1 Allocation Plan. Before starting an accelerated reliability test, it is advisable to have a plan that helps in accurately estimating reliability at operating conditions while minimizing test time and costs. A test plan should be used to decide on the appropriate stress levels that should be used (for each stress type and the amount of the test units that need to be allocated to the different stress levels (for each combination of the different stress types' levels. For the case study it used ALTA 7 software what provides a complete analysis for data from accelerated reliability tests

  20. Reliability demonstration test planning: A three dimensional consideration

    International Nuclear Information System (INIS)

    Yadav, Om Prakash; Singh, Nanua; Goel, Parveen S.

    2006-01-01

    Increasing customer demand for reliability, fierce market competition on time-to-market and cost, and highly reliable products are making reliability testing more challenging task. This paper presents a systematic approach for identifying critical elements (subsystems and components) of the system and deciding the types of test to be performed to demonstrate reliability. It decomposes the system into three dimensions (i.e. physical, functional and time) and identifies critical elements in the design by allocating system level reliability to each candidate. The decomposition of system level reliability is achieved by using criticality index. The numerical value of criticality index for each candidate is derived based on the information available from failure mode and effects analysis (FMEA) document or warranty data from a prior system. It makes use of this information to develop reliability demonstration test plan for the identified (critical) failure mechanisms and physical elements. It also highlights the benefits of using prior information in order to locate critical spots in the design and in subsequent development of test plans. A case example is presented to demonstrate the proposed approach

  1. Reliability analysis for thermal cutting method based non-explosive separation device

    International Nuclear Information System (INIS)

    Choi, Jun Woo; Hwang, Kuk Ha; Kim, Byung Kyu

    2016-01-01

    In order to increase the reliability of a separation device for a small satellite, a new non-explosive separation device is invented. This device is activated using a thermal cutting method with a Ni-Cr wire. A reliability analysis is carried out for the proposed non-explosive separation device by applying the Fault tree analysis (FTA) method. In the FTA results for the separation device, only ten single-point failure modes are found. The reliability modeling and analysis for the device are performed considering failure of the power supply, the Ni-Cr wire burns failure and unwinds, the holder separation failure, the balls separation failure, and the pin release failure. Ultimately, the reliability of the proposed device is calculated as 0.999989 with five Ni-Cr wire coils

  2. Reliability analysis for thermal cutting method based non-explosive separation device

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jun Woo; Hwang, Kuk Ha; Kim, Byung Kyu [Korea Aerospace University, Goyang (Korea, Republic of)

    2016-12-15

    In order to increase the reliability of a separation device for a small satellite, a new non-explosive separation device is invented. This device is activated using a thermal cutting method with a Ni-Cr wire. A reliability analysis is carried out for the proposed non-explosive separation device by applying the Fault tree analysis (FTA) method. In the FTA results for the separation device, only ten single-point failure modes are found. The reliability modeling and analysis for the device are performed considering failure of the power supply, the Ni-Cr wire burns failure and unwinds, the holder separation failure, the balls separation failure, and the pin release failure. Ultimately, the reliability of the proposed device is calculated as 0.999989 with five Ni-Cr wire coils.

  3. Demonstration test for reliability of valves for atomic power plants

    International Nuclear Information System (INIS)

    Hosaka, Shiro

    1978-01-01

    The demonstration test on the reliability of valves for atomic power plants being carried out by the Nuclear Engineering Test Center is reported. This test series is conducted as six-year project from FY 1976 to FY 1981 at the Isogo Test Center. The demonstration test consists of (1) environmental test, (2) reaction force test, (3) vibration test, (4) stress measurement test, (5) operational characteristic test, (6) flow resistance coefficient measuring test, (7) leakage test and (8) safety valve and relief valve test. These contents are explained about the special requirements for nuclear use, for example, the enviornmental condition after the design base accident of PWRs and BWRs, the environmental test sequence for isolation valves of containment vessels under the emergency condition, the seismic test condition for valves of nuclear use, the various stress measurements under thermal transient conditions, the leak test after 500 cycles between the normal operating conditions for PWRs and BWRs and the start up conditions and so on. As for the testing facilities, the whole flow diagram is shown, in which the environmental test section, the vibration test section, the steam test section, the hot water test section, the safety valve test section and main components are included. The specifications of each test section and main components are presented. (Nakai, Y.)

  4. Stress and reliability analyses of multilayered composite cylinder under thermal and mechanical loads

    Science.gov (United States)

    Wang, Xiaohua

    The coupling resulting from the mutual influence of material thermal and mechanical parameters is examined in the thermal stress analysis of a multilayered isotropic composite cylinder subjected to sudden axisymmetric external and internal temperature. The method of complex frequency response functions together with the Fourier transform technique is utilized. Because the coupling parameters for some composite materials, such as carbon-carbon, are very small, the effect of coupling is neglected in the orthotropic thermal stress analysis. The stress distributions in multilayered orthotropic cylinders subjected to sudden axisymmetric temperature loading combined with dynamic pressure as well as asymmetric temperature loading are also obtained. The method of Fourier series together with the Laplace transform is utilized in solving the heat conduction equation and thermal stress analysis. For brittle materials, like carbon-carbon composites, the strength variability is represented by two or three parameter Weibull distributions. The 'weakest link' principle which takes into account both the carbon-carbon composite cylinders. The complex frequency response analysis is performed on a multilayered orthotropic cylinder under asymmetrical thermal load. Both deterministic and random thermal stress and reliability analyses can be based on the results of this frequency response analysis. The stress and displacement distributions and reliability of rocket motors under static or dynamic line loads are analyzed by an elasticity approach. Rocket motors are modeled as long hollow multilayered cylinders with an air core, a thick isotropic propellant inner layer and a thin orthotropic kevlar-epoxy case. The case is treated as a single orthotropic layer or a ten layered orthotropic structure. Five material properties and the load are treated as random variable with normal distributions when the reliability of the rocket motor is analyzed by the first-order, second-moment method (FOSM).

  5. TEST-RETEST RELIABILITY OF THE CLOSED KINETIC CHAIN UPPER EXTREMITY STABILITY TEST (CKCUEST) IN ADOLESCENTS: RELIABILITY OF CKCUEST IN ADOLESCENTS.

    Science.gov (United States)

    de Oliveira, Valéria M A; Pitangui, Ana C R; Nascimento, Vinícius Y S; da Silva, Hítalo A; Dos Passos, Muana H P; de Araújo, Rodrigo C

    2017-02-01

    The Closed Kinetic Chain Upper Extremity Stability Test (CKCUEST) has been proposed as an option to assess upper limb function and stability; however, there are few studies that support the use of this test in adolescents. The purpose of the present study was to investigate the intersession reliability and agreement of three CKCUEST scores in adolescents and establish clinimetric values for this test. Test-retest reliability. Twenty-five healthy adolescents of both sexes were evaluated. The subjects performed two CKCUEST with an interval of one week between the tests. An intraclass correlation coefficient (ICC 3,3 ) two-way mixed model with a 95% interval of confidence was utilized to determine intersession reliability. A Bland-Altman graph was plotted to analyze the agreement between assessments. The presence of systematic error was evaluated by a one-sample t test. The difference between the evaluation and reevaluation was observed using a paired-sample t test. The level of significance was set at 0.05. Standard error of measurements and minimum detectable changes were calculated. The intersession reliability of the average touches score, normalized score, and power score were 0.68, 0.68 and 0.87, the standard error of measurement were 2.17, 1.35 and 6.49, and the minimal detectable change was 6.01, 3.74 and 17.98, respectively. The presence of systematic error (p test with moderate to excellent reliability when used with adolescents. The CKCUEST is a measurement with moderate to excellent reliability for adolescents. 2b.

  6. Development of thermal hydraulic models for the reliable regulatory auditing code

    Energy Technology Data Exchange (ETDEWEB)

    Chung, B. D.; Song, C. H.; Lee, Y. J.; Kwon, T. S. [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    2003-04-15

    The objective of this project is to develop thermal hydraulic models for use in improving the reliability of the regulatory auditing codes. The current year fall under the first step of the 3 year project, and the main researches were focused on identifying the candidate thermal hydraulic models for improvement and to develop prototypical model development. During the current year, the verification calculations submitted for the APR 1400 design certification have been reviewed, the experimental data from the MIDAS DVI experiment facility in KAERI have been analyzed and evaluated, candidate thermal hydraulic models for improvement have been identified, prototypical models for the improved thermal hydraulic models have been developed, items for experiment in connection with the model development have been identified, and preliminary design of the experiment has been carried out.

  7. Development of thermal hydraulic models for the reliable regulatory auditing code

    International Nuclear Information System (INIS)

    Chung, B. D.; Song, C. H.; Lee, Y. J.; Kwon, T. S.

    2003-04-01

    The objective of this project is to develop thermal hydraulic models for use in improving the reliability of the regulatory auditing codes. The current year fall under the first step of the 3 year project, and the main researches were focused on identifying the candidate thermal hydraulic models for improvement and to develop prototypical model development. During the current year, the verification calculations submitted for the APR 1400 design certification have been reviewed, the experimental data from the MIDAS DVI experiment facility in KAERI have been analyzed and evaluated, candidate thermal hydraulic models for improvement have been identified, prototypical models for the improved thermal hydraulic models have been developed, items for experiment in connection with the model development have been identified, and preliminary design of the experiment has been carried out

  8. A Method for testing the integrated thermal resistance of thermoelectric modules

    Science.gov (United States)

    Gao, Junling; Du, Qungui; Chen, Min

    2013-11-01

    The integrated thermal resistance (ITR) of thermoelectric modules (TEMs) is an important parameter that represents the thermal-conduction of ceramic substrates, copper conducting strips, and welding material used in the TEM as well as the thermal contact resistances between different materials. In this study, an accurate and practical test method is proposed for the ITR of TEMs according to thermoelectric heat transfer theory and the equivalent characteristics of heat flux through the cold and hot sides of TEMs in an open-circuit situation. By using such measurements and comparisons, it is verified that the measured ITR value in our mode is accurate and reliable. In particular this method accurately predicts the actual operating conditions of TEMs, in which TEMs are under certain mechanical pressure. It effectively solves the problem of thermal resistance extraction from operating TEMs and is of great significance in their analysis and optimization.

  9. A reliability design method for a lithium-ion battery pack considering the thermal disequilibrium in electric vehicles

    Science.gov (United States)

    Xia, Quan; Wang, Zili; Ren, Yi; Sun, Bo; Yang, Dezhen; Feng, Qiang

    2018-05-01

    With the rapid development of lithium-ion battery technology in the electric vehicle (EV) industry, the lifetime of the battery cell increases substantially; however, the reliability of the battery pack is still inadequate. Because of the complexity of the battery pack, a reliability design method for a lithium-ion battery pack considering the thermal disequilibrium is proposed in this paper based on cell redundancy. Based on this method, a three-dimensional electric-thermal-flow-coupled model, a stochastic degradation model of cells under field dynamic conditions and a multi-state system reliability model of a battery pack are established. The relationships between the multi-physics coupling model, the degradation model and the system reliability model are first constructed to analyze the reliability of the battery pack and followed by analysis examples with different redundancy strategies. By comparing the reliability of battery packs of different redundant cell numbers and configurations, several conclusions for the redundancy strategy are obtained. More notably, the reliability does not monotonically increase with the number of redundant cells for the thermal disequilibrium effects. In this work, the reliability of a 6 × 5 parallel-series configuration is the optimal system structure. In addition, the effect of the cell arrangement and cooling conditions are investigated.

  10. Solar-Thermal Engine Testing

    Science.gov (United States)

    Tucker, Stephen; Salvail, Pat; Haynes, Davy (Technical Monitor)

    2001-01-01

    A solar-thermal engine serves as a high-temperature solar-radiation absorber, heat exchanger, and rocket nozzle. collecting concentrated solar radiation into an absorber cavity and transferring this energy to a propellant as heat. Propellant gas can be heated to temperatures approaching 4,500 F and expanded in a rocket nozzle, creating low thrust with a high specific impulse (I(sub sp)). The Shooting Star Experiment (SSE) solar-thermal engine is made of 100 percent chemical vapor deposited (CVD) rhenium. The engine 'module' consists of an engine assembly, propellant feedline, engine support structure, thermal insulation, and instrumentation. Engine thermal performance tests consist of a series of high-temperature thermal cycles intended to characterize the propulsive performance of the engines and the thermal effectiveness of the engine support structure and insulation system. A silicone-carbide electrical resistance heater, placed inside the inner shell, substitutes for solar radiation and heats the engine. Although the preferred propellant is hydrogen, the propellant used in these tests is gaseous nitrogen. Because rhenium oxidizes at elevated temperatures, the tests are performed in a vacuum chamber. Test data will include transient and steady state temperatures on selected engine surfaces, propellant pressures and flow rates, and engine thrust levels. The engine propellant-feed system is designed to Supply GN2 to the engine at a constant inlet pressure of 60 psia, producing a near-constant thrust of 1.0 lb. Gaseous hydrogen will be used in subsequent tests. The propellant flow rate decreases with increasing propellant temperature, while maintaining constant thrust, increasing engine I(sub sp). In conjunction with analytical models of the heat exchanger, the temperature data will provide insight into the effectiveness of the insulation system, the structural support system, and the overall engine performance. These tests also provide experience on operational

  11. Reliability demonstration test planning using bayesian analysis

    International Nuclear Information System (INIS)

    Chandran, Senthil Kumar; Arul, John A.

    2003-01-01

    In Nuclear Power Plants, the reliability of all the safety systems is very critical from the safety viewpoint and it is very essential that the required reliability requirements be met while satisfying the design constraints. From practical experience, it is found that the reliability of complex systems such as Safety Rod Drive Mechanism is of the order of 10 -4 with an uncertainty factor of 10. To demonstrate the reliability of such systems is prohibitive in terms of cost and time as the number of tests needed is very large. The purpose of this paper is to develop a Bayesian reliability demonstrating testing procedure for exponentially distributed failure times with gamma prior distribution on the failure rate which can be easily and effectively used to demonstrate component/subsystem/system reliability conformance to stated requirements. The important questions addressed in this paper are: With zero failures, how long one should perform the tests and how many components are required to conclude with a given degree of confidence, that the component under test, meets the reliability requirement. The procedure is explained with an example. This procedure can also be extended to demonstrate with more number of failures. The approach presented is applicable for deriving test plans for demonstrating component failure rates of nuclear power plants, as the failure data for similar components are becoming available in existing plants elsewhere. The advantages of this procedure are the criterion upon which the procedure is based is simple and pertinent, the fitting of the prior distribution is an integral part of the procedure and is based on the use of information regarding two percentiles of this distribution and finally, the procedure is straightforward and easy to apply in practice. (author)

  12. Indirect thermal control for improved reliability of Modular Multilevel Converter by utilizing circulating current

    DEFF Research Database (Denmark)

    Dowlatabadi, Mohammadkazem Bakhshizadeh; Ma, Ke; Loh, Poh Chiang

    2015-01-01

    semiconductor devices are comprehensively investigated. Also a novel control strategy by utilizing the circulating current is proposed to enhance the reliability performance of MMC in order to limit the amplitude of thermal cycles. It is concluded that the circulating current may change the losses and thermal...

  13. A New Metre for Cheap, Quick, Reliable and Simple Thermal Transmittance (U-Value) Measurements in Buildings.

    Science.gov (United States)

    Andújar Márquez, José Manuel; Martínez Bohórquez, Miguel Ángel; Gómez Melgar, Sergio

    2017-09-03

    This paper deals with the thermal transmittance measurement focused on buildings and specifically in building energy retrofitting. Today, if many thermal transmittance measurements in a short time are needed, the current devices, based on the measurement of the heat flow through the wall, cannot carry out them, except if a great amount of devices are used at once along with intensive and tedious post-processing and analysis work. In this paper, from well-known physical laws, authors develop a methodology based on three temperatures measurements, which is implemented by a novel thermal transmittance metre. The paper shows its development step by step. As a result the developed device is modular, scalable, and fully wireless; it is capable of taking as many measurements at once as user needs. The developed system is compared working together on a same test to the currently used one based on heat flow. The results show that the developed metre allows carrying out thermal transmittance measurements in buildings in a cheap, quick, reliable and simple way.

  14. Ouellette Thermal Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Thermal Test Facility is a joint Army/Navy state-of-the-art facility (8,100 ft2) that was designed to:Evaluate and characterize the effect of flame and thermal...

  15. Reliability Estimation Based Upon Test Plan Results

    National Research Council Canada - National Science Library

    Read, Robert

    1997-01-01

    The report contains a brief summary of aspects of the Maximus reliability point and interval estimation technique as it has been applied to the reliability of a device whose surveillance tests contain...

  16. Basic Concepts in Classical Test Theory: Tests Aren't Reliable, the Nature of Alpha, and Reliability Generalization as a Meta-analytic Method.

    Science.gov (United States)

    Helms, LuAnn Sherbeck

    This paper discusses the fact that reliability is about scores and not tests and how reliability limits effect sizes. The paper also explores the classical reliability coefficients of stability, equivalence, and internal consistency. Stability is concerned with how stable test scores will be over time, while equivalence addresses the relationship…

  17. Design for reliability: NASA reliability preferred practices for design and test

    Science.gov (United States)

    Lalli, Vincent R.

    1994-01-01

    This tutorial summarizes reliability experience from both NASA and industry and reflects engineering practices that support current and future civil space programs. These practices were collected from various NASA field centers and were reviewed by a committee of senior technical representatives from the participating centers (members are listed at the end). The material for this tutorial was taken from the publication issued by the NASA Reliability and Maintainability Steering Committee (NASA Reliability Preferred Practices for Design and Test. NASA TM-4322, 1991). Reliability must be an integral part of the systems engineering process. Although both disciplines must be weighed equally with other technical and programmatic demands, the application of sound reliability principles will be the key to the effectiveness and affordability of America's space program. Our space programs have shown that reliability efforts must focus on the design characteristics that affect the frequency of failure. Herein, we emphasize that these identified design characteristics must be controlled by applying conservative engineering principles.

  18. ENDF/B Thermal Data Testing

    CERN Document Server

    McCrosson, F J

    2001-01-01

    The thermal data testing group is concerned with establishing the merit of ENDF/B cross sections for the analysis of thermal systems. The integral experiments used in the testing are designed to analyze each of the phenomena identified in the familiar four-factor formula. For brevity, only the testing of the cross sections in uranium systems is described in this report.

  19. Reliability of movement control tests in the lumbar spine

    Directory of Open Access Journals (Sweden)

    de Bruin Eling D

    2007-09-01

    Full Text Available Abstract Background Movement control dysfunction [MCD] reduces active control of movements. Patients with MCD might form an important subgroup among patients with non specific low back pain. The diagnosis is based on the observation of active movements. Although widely used clinically, only a few studies have been performed to determine the test reliability. The aim of this study was to determine the inter- and intra-observer reliability of movement control dysfunction tests of the lumbar spine. Methods We videoed patients performing a standardized test battery consisting of 10 active movement tests for motor control in 27 patients with non specific low back pain and 13 patients with other diagnoses but without back pain. Four physiotherapists independently rated test performances as correct or incorrect per observation, blinded to all other patient information and to each other. The study was conducted in a private physiotherapy outpatient practice in Reinach, Switzerland. Kappa coefficients, percentage agreements and confidence intervals for inter- and intra-rater results were calculated. Results The kappa values for inter-tester reliability ranged between 0.24 – 0.71. Six tests out of ten showed a substantial reliability [k > 0.6]. Intra-tester reliability was between 0.51 – 0.96, all tests but one showed substantial reliability [k > 0.6]. Conclusion Physiotherapists were able to reliably rate most of the tests in this series of motor control tasks as being performed correctly or not, by viewing films of patients with and without back pain performing the task.

  20. Reliability test for reactor internals rejuvenation technology

    International Nuclear Information System (INIS)

    Uchiyama, Junichi

    1998-01-01

    41 transparencies were presented on the subject of 'Reliability test for reactor internals rejuvenation technology'. The items presented give an introduction on the management of plant life in Japan and introduce the Nuclear Power Engineering Corporation (NUPEC). The question of what reliability tests for rejuvenation of reactor internals are is discussed in some detail and an outline of each test is given. Altogether six methods to rejuvenate reactor internals are presented, two of which have already been applied to actual plants. The presentation was supported by many detailed drawings and images

  1. Thermal Cycle Reliability and Failure Mechanisms of CCGA and PBGA Assemblies with and without Corner Staking

    Science.gov (United States)

    Ghaffarian, Reza

    2008-01-01

    Area array packages (AAPs) with 1.27 mm pitch have been the packages of choice for commercial applications; they are now starting to be implemented for use in military and aerospace applications. Thermal cycling characteristics of plastic ball grid array (PBGA) and chip scale package assemblies, because of their wide usage for commercial applications, have been extensively reported on in literature. Thermal cycling represents the on-off environmental condition for most electronic products and therefore is a key factor that defines reliability.However, very limited data is available for thermal cycling behavior of ceramic packages commonly used for the aerospace applications. For high reliability applications, numerous AAPs are available with an identical design pattern both in ceramic and plastic packages. This paper compares assembly reliability of ceramic and plastic packages with the identical inputs/outputs(I/Os) and pattern. The ceramic package was in the form of ceramic column grid array (CCGA) with 560 I/Os peripheral array with the identical pad design as its plastic counterpart.

  2. Thermal fatigue equipment to test joints of materials for high heat flux components

    International Nuclear Information System (INIS)

    Visca, E.; Libera, S.; Orsini, A.; Riccardi, B.; Sacchetti, M.

    2000-01-01

    The activity, carried out in the framework of an ITER divertor task, was aimed at defining a suitable method in order to qualify junctions between armour materials and heat sink of plasma-facing components (PFCs) mock-ups. An equipment able to perform thermal fatigue testing by electrical heating and active water-cooling was constructed and a standard for the sample was defined. In this equipment, during operation cycles, two samples are heated by thermal contact up to a relevant temperature value (350 deg. C) and then the water flow is switched on, thus producing fast cooling with time constants and gradients close to the real operating conditions. The equipment works with a test cycle of about 60 s and is suitable for continuous operation. A complete test consists of about 10000 cycles. After the assembling, the equipment and the control software were optimized to obtain a good reliability. Preliminary tests on mock-ups with flat CFC tiles joined to copper heat sink were performed. Finite-elements calculations were carried out in order to estimate the value of the thermal stresses arising close to the joint under the transient conditions that are characteristic of this equipment

  3. Reliability and validity of two isometric squat tests.

    Science.gov (United States)

    Blazevich, Anthony J; Gill, Nicholas; Newton, Robert U

    2002-05-01

    The purpose of the present study was first to examine the reliability of isometric squat (IS) and isometric forward hack squat (IFHS) tests to determine if repeated measures on the same subjects yielded reliable results. The second purpose was to examine the relation between isometric and dynamic measures of strength to assess validity. Fourteen male subjects performed maximal IS and IFHS tests on 2 occasions and 1 repetition maximum (1-RM) free-weight squat and forward hack squat (FHS) tests on 1 occasion. The 2 tests were found to be highly reliable (intraclass correlation coefficient [ICC](IS) = 0.97 and ICC(IFHS) = 1.00). There was a strong relation between average IS and 1-RM squat performance, and between IFHS and 1-RM FHS performance (r(squat) = 0.77, r(FHS) = 0.76; p squat and FHS test performances (r squat and FHS test performance can be attributed to differences in the movement patterns of the tests

  4. Reliability of four experimental mechanical pain tests in children

    Directory of Open Access Journals (Sweden)

    Soee AL

    2013-02-01

    Full Text Available Ann-Britt L Soee,1 Lise L Thomsen,2 Birte Tornoe,1,3 Liselotte Skov11Department of Pediatrics, Children’s Headache Clinic, Copenhagen University Hospital Herlev, Copenhagen, Denmark; 2Department of Neuropediatrics, Juliane Marie Centre, Copenhagen University Hospital Rigshospitalet, København Ø, Denmark; 3Department of Physiotherapy, Medical Department O, Copenhagen University Hospital Herlev, Herlev, DenmarkPurpose: In order to study pain in children, it is necessary to determine whether pain measurement tools used in adults are reliable measurements in children. The aim of this study was to explore the intrasession reliability of pressure pain thresholds (PPT in healthy children. Furthermore, the aim was also to study the intersession reliability of the following four tests: (1 Total Tenderness Score; (2 PPT; (3 Visual Analog Scale score at suprapressure pain threshold; and (4 area under the curve (stimulus–response functions for pressure versus pain.Participants and methods: Twenty-five healthy school children, 8–14 years of age, participated. Test 2, PPT, was repeated three times at 2 minute intervals on the same day to estimate PPT intrasession reliability using Cronbach’s alpha. Tests 1–4 were repeated after median 21 (interquartile range 10.5–22 days, and Pearson’s correlation coefficient was used to describe the intersession reliability.Results: The PPT test was precise and reliable (Cronbach’s alpha ≥ 0.92. All tests showed a good to excellent correlation between days (intersessions r = 0.66–0.81. There were no indications of significant systematic differences found in any of the four tests between days.Conclusion: All tests seemed to be reliable measurements in pain evaluation in healthy children aged 8–14 years. Given the small sample size, this conclusion needs to be confirmed in future studies.Keywords: repeatability, intraindividual reliability, pressure pain threshold, pain measurement, algometer

  5. Reliability of a Computerized Neurocognitive Test in Baseline Concussion Testing of High School Athletes.

    Science.gov (United States)

    MacDonald, James; Duerson, Drew

    2015-07-01

    Baseline assessments using computerized neurocognitive tests are frequently used in the management of sport-related concussions. Such testing is often done on an annual basis in a community setting. Reliability is a fundamental test characteristic that should be established for such tests. Our study examined the test-retest reliability of a computerized neurocognitive test in high school athletes over 1 year. Repeated measures design. Two American high schools. High school athletes (N = 117) participating in American football or soccer during the 2011-2012 and 2012-2013 academic years. All study participants completed 2 baseline computerized neurocognitive tests taken 1 year apart at their respective schools. The test measures performance on 4 cognitive tasks: identification speed (Attention), detection speed (Processing Speed), one card learning accuracy (Learning), and one back speed (Working Memory). Reliability was assessed by measuring the intraclass correlation coefficient (ICC) between the repeated measures of the 4 cognitive tasks. Pearson and Spearman correlation coefficients were calculated as a secondary outcome measure. The measure for identification speed performed best (ICC = 0.672; 95% confidence interval, 0.559-0.760) and the measure for one card learning accuracy performed worst (ICC = 0.401; 95% confidence interval, 0.237-0.542). All tests had marginal or low reliability. In a population of high school athletes, computerized neurocognitive testing performed in a community setting demonstrated low to marginal test-retest reliability on baseline assessments 1 year apart. Further investigation should focus on (1) improving the reliability of individual tasks tested, (2) controlling for external factors that might affect test performance, and (3) identifying the ideal time interval to repeat baseline testing in high school athletes. Computerized neurocognitive tests are used frequently in high school athletes, often within a model of baseline testing

  6. Influences on and Limitations of Classical Test Theory Reliability Estimates.

    Science.gov (United States)

    Arnold, Margery E.

    It is incorrect to say "the test is reliable" because reliability is a function not only of the test itself, but of many factors. The present paper explains how different factors affect classical reliability estimates such as test-retest, interrater, internal consistency, and equivalent forms coefficients. Furthermore, the limits of classical test…

  7. Determining the reliability function of the thermal power system in power plant "Nikola Tesla, Block B1"

    Directory of Open Access Journals (Sweden)

    Kalaba Dragan V.

    2015-01-01

    Full Text Available Representation of probabilistic technique for evaluation of thermal power system reliability is the main subject of this paper. The system of thermal power plant under study consists of three subsystems and the reliability assessment is based on a sixteen-year failure database. By applying the mathematical theory of reliability to exploitation research data and using complex two-parameter Weibull distribution, the theoretical reliability functions of specified system have been determined. Obtained probabilistic laws of failure occurrence have confirmed a hypothesis that the distribution of the observed random variable fully describes behaviour of such a system in terms of reliability. Shown results make possible to acquire a better knowledge of current state of the system, as well as a more accurate estimation of its behavior during future exploitation. Final benefit is opportunity for potential improvement of complex system maintenance policies aimed at the reduction of unexpected failure occurrences.

  8. Test-retest reliability of the Work Ability Index questionnaire

    NARCIS (Netherlands)

    de Zwart, B. C. H.; Frings-Dresen, M. H. W.; Van Duivenbooden, J. C.

    2002-01-01

    The goal of the study was to assess the test-retest reliability of the Work Ability Index (WAI) questionnaire. Reliability was tested using a test-retest design with a 4 week interval between measurements. Valid data were collected among 97 elderly construction workers aged 40 years and older. We

  9. Solar Thermal Upper Stage Cryogen System Engineering Checkout Test

    Science.gov (United States)

    Olsen, A. D; Cady, E. C.; Jenkins, D. S.

    1999-01-01

    The Solar Thermal Upper Stage technology (STUSTD) program is a solar thermal propulsion technology program cooperatively sponsored by a Boeing led team and by NASA MSFC. A key element of its technology program is development of a liquid hydrogen (LH2) storage and supply system which employs multi-layer insulation, liquid acquisition devices, active and passive thermodynamic vent systems, and variable 40W tank heaters to reliably provide near constant pressure H2 to a solar thermal engine in the low-gravity of space operation. The LH2 storage and supply system is designed to operate as a passive, pressure fed supply system at a constant pressure of about 45 psia. During operation of the solar thermal engine over a small portion of the orbit the LH2 storage and supply system propulsively vents through the enjoy at a controlled flowrate. During the long coast portion of the orbit, the LH2 tank is locked up (unvented). Thus, all of the vented H2 flow is used in the engine for thrust and none is wastefully vented overboard. The key to managing the tank pressure and therefore the H2 flow to the engine is to manage and balance the energy flow into the LH2 tank with the MLI and tank heaters with the energy flow out of the LH2 tank through the vented H2 flow. A moderate scale (71 cu ft) LH2 storage and supply system was installed and insulated at the NASA MSFC Test Area 300. The operation of the system is described in this paper. The test program for the LH2 system consisted of two parts: 1) a series of engineering tests to characterize the performance of the various components in the system: and 2) a 30-day simulation of a complete LEO and GEO transfer mission. This paper describes the results of the engineering tests, and correlates these results with analytical models used to design future advanced Solar Orbit Transfer Vehicles.

  10. NASA reliability preferred practices for design and test

    Science.gov (United States)

    1991-01-01

    Given here is a manual that was produced to communicate within the aerospace community design practices that have contributed to NASA mission success. The information represents the best technical advice that NASA has to offer on reliability design and test practices. Topics covered include reliability practices, including design criteria, test procedures, and analytical techniques that have been applied to previous space flight programs; and reliability guidelines, including techniques currently applied to space flight projects, where sufficient information exists to certify that the technique will contribute to mission success.

  11. Face Perception and Test Reliabilities in Congenital Prosopagnosia in Seven Tests

    Directory of Open Access Journals (Sweden)

    Janina Esins

    2016-01-01

    Full Text Available Congenital prosopagnosia, the innate impairment in recognizing faces, is a very heterogeneous disorder with different phenotypical manifestations. To investigate the nature of prosopagnosia in more detail, we tested 16 prosopagnosics and 21 controls with an extended test battery addressing various aspects of face recognition. Our results show that prosopagnosics exhibited significant impairments in several face recognition tasks: impaired holistic processing (they were tested amongst others with the Cambridge Face Memory Test (CFMT as well as reduced processing of configural information of faces. This test battery also revealed some new findings. While controls recognized moving faces better than static faces, prosopagnosics did not exhibit this effect. Furthermore, prosopagnosics had significantly impaired gender recognition—which is shown on a groupwise level for the first time in our study. There was no difference between groups in the automatic extraction of face identity information or in object recognition as tested with the Cambridge Car Memory Test. In addition, a methodological analysis of the tests revealed reduced reliability for holistic face processing tests in prosopagnosics. To our knowledge, this is the first study to show that prosopagnosics showed a significantly reduced reliability coefficient (Cronbach’s alpha in the CFMT compared to the controls. We suggest that compensatory strategies employed by the prosopagnosics might be the cause for the vast variety of response patterns revealed by the reduced test reliability. This finding raises the question whether classical face tests measure the same perceptual processes in controls and prosopagnosics.

  12. Research on the Reliability Testing of Electrical Automation Control Equipment

    OpenAIRE

    Yongjie Luo

    2014-01-01

    According to the author’s many years’ work experience, this paper first discusses the concepts of electrical automation control equipment reliability testing, and then analyzes the test method of electrical automation control equipment reliability testing, finally, on this basis, this article discusses how to determine the reliability test method of electrical automation control equipment. Results of this study will provide a useful reference for electrical automation control equipment reliab...

  13. Test rig overview for validation and reliability testing of shutdown system software

    International Nuclear Information System (INIS)

    Zhao, M.; McDonald, A.; Dick, P.

    2007-01-01

    The test rig for Validation and Reliability Testing of shutdown system software has been upgraded from the AECL Windows-based test rig previously used for CANDU6 stations. It includes a Virtual Trip Computer, which is a software simulation of the functional specification of the trip computer, and a real-time trip computer simulator in a separate chassis, which is used during the preparation of trip computer test cases before the actual trip computers are available. This allows preparation work for Validation and Reliability Testing to be performed in advance of delivery of actual trip computers to maintain a project schedule. (author)

  14. Reliability of Maximal Strength Testing in Novice Weightlifters

    Science.gov (United States)

    Loehr, James A.; Lee, Stuart M. C.; Feiveson, Alan H.; Ploutz-Snyder, Lori L.

    2009-01-01

    The one repetition maximum (1RM) is a criterion measure of muscle strength. However, the reliability of 1RM testing in novice subjects has received little attention. Understanding this information is crucial to accurately interpret changes in muscle strength. To evaluate the test-retest reliability of a squat (SQ), heel raise (HR), and deadlift (DL) 1RM in novice subjects. Twenty healthy males (31 plus or minus 5 y, 179.1 plus or minus 6.1 cm, 81.4 plus or minus 10.6 kg) with no weight training experience in the previous six months participated in four 1RM testing sessions, with each session separated by 5-7 days. SQ and HR 1RM were conducted using a smith machine; DL 1RM was assessed using free weights. Session 1 was considered a familiarization and was not included in the statistical analyses. Repeated measures analysis of variance with Tukey fs post-hoc tests were used to detect between-session differences in 1RM (p.0.05). Test-retest reliability was evaluated by intraclass correlation coefficients (ICC). During Session 2, the SQ and DL 1RM (SQ: 90.2 }4.3, DL: 75.9 }3.3 kg) were less than Session 3 (SQ: 95.3 }4.1, DL: 81.5 plus or minus 3.5 kg) and Session 4 (SQ: 96.6 }4.0, DL: 82.4 }3.9 kg), but there were no differences between Session 3 and Session 4. HR 1RM measured during Session 2 (150.1 }3.7 kg) and Session 3 (152.5 }3.9 kg) were not different from one another, but both were less than Session 4 (157.5 }3.8 kg). The reliability (ICC) of 1RM measures for Sessions 2-4 were 0.88, 0.83, and 0.87, for SQ, HR, and DL, respectively. When considering only Sessions 3 and 4, the reliability was 0.93, 0.91, and 0.86 for SQ, HR, and DL, respectively. One familiarization session and 2 test sessions (for SQ and DL) were required to obtain excellent reliability (ICC greater than or equal to 0.90) in 1RM values with novice subjects. We were unable to attain this level of reliability following 3 HR testing sessions therefore additional sessions may be required to obtain an

  15. Reliability Analysis and Test Planning using CAPO-Test for Existing Structures

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Engelund, S.; Faber, Michael Havbro

    2000-01-01

    Evaluation of the reliability of existing concrete structures often requires that the compressive strength of the concrete is estimated on the basis of tests performed with concrete samples from the structure considered. In this paper the CAPO-test method is considered. The different sources...... of uncertainty related to this method are described. It is shown how the uncertainty in the transformation from the CAPO-test results to estimates of the concrete strength can be modeled. Further, the statistical uncertainty is modeled using Bayesian statistics. Finally, it is shown how reliability-based optimal...... planning of CAPO-tests can be performed taking into account the expected costs due to the CAPO-tests and possible repair or failure of the structure considered. An illustrative example is presented where the CAPO-test is compared with conventional concrete cylinder compression tests performed on cores...

  16. Operational reliability testing of FBR fuel in EBR-II

    International Nuclear Information System (INIS)

    Asaga, Takeo; Ukai, Shigeharu; Nomura, Shigeo; Shikakura, Sakae

    1991-01-01

    The operational reliability testing of FBR fuel has been conducting in EBR-II as a DOE/PNC collaboration program. This paper reviews the achieved summary of Phase-I test as well as outline of progressing Phase-II test. In Phase-I test, the reliability of FBR fuel pins including 'MONJU' fuel was demonstrated at the event of operational transient. Continued operation of the failed pins was also shown to be feasible without affecting the plant operation. The objectives of the Phase-II test is to extend the data base relating with the operational reliability for long life fuel, and to supply the highly quantitative evaluation. The valuable insight obtained in Phase-II test are considerably expected to be useful toward the achievement of commercial FBR. (author)

  17. Optimal number of tests to achieve and validate product reliability

    International Nuclear Information System (INIS)

    Ahmed, Hussam; Chateauneuf, Alaa

    2014-01-01

    The reliability validation of engineering products and systems is mandatory for choosing the best cost-effective design among a series of alternatives. Decisions at early design stages have a large effect on the overall life cycle performance and cost of products. In this paper, an optimization-based formulation is proposed by coupling the costs of product design and validation testing, in order to ensure the product reliability with the minimum number of tests. This formulation addresses the question about the number of tests to be specified through reliability demonstration necessary to validate the product under appropriate confidence level. The proposed formulation takes into account the product cost, the failure cost and the testing cost. The optimization problem can be considered as a decision making system according to the hierarchy of structural reliability measures. The numerical examples show the interest of coupling design and testing parameters. - Highlights: • Coupled formulation for design and testing costs, with lifetime degradation. • Cost-effective testing optimization to achieve reliability target. • Solution procedure for nested aleatoric and epistemic variable spaces

  18. Reliability performance of standby equipment with periodic testing

    International Nuclear Information System (INIS)

    Sim, S.H.

    1985-11-01

    In this report, the reliability performance of standby equipment subjected to periodic testing is studied. analytical expressions have been derived for reliability measures, such as the man accumulated operating time to failure, the expected number of tests between two consecutive failures, the mean time to failure following an emergency start-up and the probability of failing to complete an emergency mission of a specified duration. These results are useful for the reliability assessment of standby equipment such as combustion turbine units of the emergency power supply system, and of the Class III power system at a nuclear generating station

  19. Validity and reliability of the NAB Naming Test.

    Science.gov (United States)

    Sachs, Bonnie C; Rush, Beth K; Pedraza, Otto

    2016-05-01

    Confrontation naming is commonly assessed in neuropsychological practice, but few standardized measures of naming exist and those that do are susceptible to the effects of education and culture. The Neuropsychological Assessment Battery (NAB) Naming Test is a 31-item measure used to assess confrontation naming. Despite adequate psychometric information provided by the test publisher, there has been limited independent validation of the test. In this study, we investigated the convergent and discriminant validity, internal consistency, and alternate forms reliability of the NAB Naming Test in a sample of adults (Form 1: n = 247, Form 2: n = 151) clinically referred for neuropsychological evaluation. Results indicate adequate-to-good internal consistency and alternate forms reliability. We also found strong convergent validity as demonstrated by relationships with other neurocognitive measures. We found preliminary evidence that the NAB Naming Test demonstrates a more pronounced ceiling effect than other commonly used measures of naming. To our knowledge, this represents the largest published independent validation study of the NAB Naming Test in a clinical sample. Our findings suggest that the NAB Naming Test demonstrates adequate validity and reliability and merits consideration in the test arsenal of clinical neuropsychologists.

  20. Thermal Loading and Reliability of 10 MW Multilevel Wind Power Converter at Different Wind Roughness Classes

    DEFF Research Database (Denmark)

    Isidori, Andrea; Rossi, Fabio Mario; Blaabjerg, Frede

    2014-01-01

    This paper focuses on the design, thermal loading, and reliability of a three-level neutral-point-clamped back-to-back full-scale converter for a 10-MW direct-drive wind turbine equipped with a permanent-magnet synchronous generator. The reliability performance of the three-level converter...... is strongly influenced by the thermal behavior of the semiconductor devices and their mission profile which directly affects the lifetime and the cost of the entire converter. Therefore, a simulation platform is developed in a Matlab/Simulink and PLECS simulation environment to analyze the dynamics...... of the system using different kinds of modulation strategies and analyzing the different wind-load conditions that are dependent on roughness classes. This paper shows that the 60 ° discontinuous pulsewidth-modulation strategies allow better thermal performance and increase the estimated lifetime...

  1. Thermal loading and reliability of 10 MW multilevel wind power converter at different wind roughness classes

    DEFF Research Database (Denmark)

    Isidori, Andrea; Rossi, Fabio Mario; Blaabjerg, Frede

    2012-01-01

    This paper focuses on the design, thermal loading and reliability of a three-level Neutral Point Clamped (3-L NPC) back-to-back full scale converter for a 10 MW direct-drive wind turbine equipped with a Permanent Magnet Synchronous Generator (PMSG). The reliability performance of the three......-level converter is strongly influenced by the thermal behaviour of the semiconductor devices and their mission profile which directly affects the lifetime and the cost of the whole converter. Therefore, the simulation platform is developed in Matlab/Simulink and PLECS simulation environment to analyse...... the dynamics of the system using different kinds of modulation strategies and analyzing different wind load conditions dependent on roughness classes. It is concluded that 60° discontinuous PWM modulation strategies show better thermal performance and increase the estimated lifetime of the converter...

  2. Test-retest and interrater reliability of the functional lower extremity evaluation.

    Science.gov (United States)

    Haitz, Karyn; Shultz, Rebecca; Hodgins, Melissa; Matheson, Gordon O

    2014-12-01

    Repeated-measures clinical measurement reliability study. To establish the reliability and face validity of the Functional Lower Extremity Evaluation (FLEE). The FLEE is a 45-minute battery of 8 standardized functional performance tests that measures 3 components of lower extremity function: control, power, and endurance. The reliability and normative values for the FLEE in healthy athletes are unknown. A face validity survey for the FLEE was sent to sports medicine personnel to evaluate the level of importance and frequency of clinical usage of each test included in the FLEE. The FLEE was then administered and rated for 40 uninjured athletes. To assess test-retest reliability, each athlete was tested twice, 1 week apart, by the same rater. To assess interrater reliability, 3 raters scored each athlete during 1 of the testing sessions. Intraclass correlation coefficients were used to assess the test-retest and interrater reliability of each of the FLEE tests. In the face validity survey, the FLEE tests were rated as highly important by 58% to 71% of respondents but frequently used by only 26% to 45% of respondents. Interrater reliability intraclass correlation coefficients ranged from 0.83 to 1.00, and test-retest reliability ranged from 0.71 to 0.95. The FLEE tests are considered clinically important for assessing lower extremity function by sports medicine personnel but are underused. The FLEE also is a reliable assessment tool. Future studies are required to determine if use of the FLEE to make return-to-play decisions may reduce reinjury rates.

  3. NUPEC proves reliability of LWR fuel assemblies

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    It is very important in assuring the safety of nuclear reactors to confirm the reliability of fuel assemblies. The test program of the Nuclear Power Engineering Center on the reliability of fuel assemblies has verified the high performance and reliability of Japanese LWR fuels, and confirmed the propriety of their design and fabrication. This claim is based on the data obtained from the fuel assemblies irradiated in commercial reactors. The NUPEC program includes irradiation test which has been conducted for 11 years since fiscal 1976, and the maximum thermal loading test using the out of pile test facilities simulating a real reactor which has been continued since fiscal 1978. The irradiation test on BWR fuel assemblies in No.3 reactor in Fukushima No.1 Nuclear Power Station, Tokyo Electric Power Co., Inc., and on PWR fuel assemblies in No.3 reactor in Mihama Power Station, Kansai Electric Power Co., Inc., and the maximum thermal loading test on BWR and PWR fuel assemblies are reported. The series of postirradiation examination of the fuel assemblies used for commercial reactors was conducted for the first time in Japan, and the highly systematic data on 27 items were obtained. (Kako, I.)

  4. Test–re-test reliability and inter-rater reliability of a digital pelvic inclinometer in young, healthy males and females

    Directory of Open Access Journals (Sweden)

    Chris Beardsley

    2016-03-01

    Full Text Available Objective. The purpose of this study was to investigate the reliability of a digital pelvic inclinometer (DPI for measuring sagittal plane pelvic tilt in 18 young, healthy males and females. Method. The inter-rater reliability and test–re-test reliabilities of the DPI for measuring pelvic tilt in standing on both the right and left sides of the pelvis were measured by two raters carrying out two rating sessions of the same subjects, three weeks apart. Results. For measuring pelvic tilt, inter-rater reliability was designated as good on both sides (ICC = 0.81–0.88, test–re-test reliability within a single rating session was designated as good on both sides (ICC = 0.88–0.95, and test–re-test reliability between two rating sessions was designated as moderate on the left side (ICC = 0.65 and good on the right side (ICC = 0.85. Conclusion. Inter-rater reliability and test–re-test reliability within a single rating session of the DPI in measuring pelvic tilt were both good, while test–re-test reliability between rating sessions was moderate-to-good. Caution is required regarding the interpretation of the test–re-test reliability within a single rating session, as the raters were not blinded. Further research is required to establish validity.

  5. Test-Retest Reliability and Predictive Validity of the Implicit Association Test in Children

    Science.gov (United States)

    Rae, James R.; Olson, Kristina R.

    2018-01-01

    The Implicit Association Test (IAT) is increasingly used in developmental research despite minimal evidence of whether children's IAT scores are reliable across time or predictive of behavior. When test-retest reliability and predictive validity have been assessed, the results have been mixed, and because these studies have differed on many…

  6. Thermal and Alignment Analysis of the Instrument-Level ATLAS Thermal Vacuum Test

    Science.gov (United States)

    Bradshaw, Heather

    2012-01-01

    This paper describes the thermal analysis and test design performed in preparation for the ATLAS thermal vacuum test. NASA's Advanced Topographic Laser Altimeter System (ATLAS) will be flown as the sole instrument aboard the Ice, Cloud, and land Elevation Satellite-2 (ICESat-2). It will be used to take measurements of topography and ice thickness for Arctic and Antarctic regions, providing crucial data used to predict future changes in worldwide sea levels. Due to the precise measurements ATLAS is taking, the laser altimeter has very tight pointing requirements. Therefore, the instrument is very sensitive to temperature-induced thermal distortions. For this reason, it is necessary to perform a Structural, Thermal, Optical Performance (STOP) analysis not only for flight, but also to ensure performance requirements can be operationally met during instrument-level thermal vacuum testing. This paper describes the thermal model created for the chamber setup, which was used to generate inputs for the environmental STOP analysis. This paper also presents the results of the STOP analysis, which indicate that the test predictions adequately replicate the thermal distortions predicted for flight. This is a new application of an existing process, as STOP analyses are generally performed to predict flight behavior only. Another novel aspect of this test is that it presents the opportunity to verify pointing results of a STOP model, which is not generally done. It is possible in this case, however, because the actual pointing will be measured using flight hardware during thermal vacuum testing and can be compared to STOP predictions.

  7. Thermal fatigue testing of a diffusion-bonded beryllium divertor mock-up under ITER relevant conditions

    International Nuclear Information System (INIS)

    Youchison, D.L.; Guiniiatouline, R.; Watson, R.D.

    1994-01-01

    Thermal response and thermal fatigue tests of four 5 mm thick beryllium tiles on a Russian divertor mock-up were completed on the Electron Beam Test System at Sandia National Laboratories. The beryllium tiles were diffusion bonded onto an OFHC copper saddleblock and a DSCu (MAGT) tube containing a porous coating. Thermal response tests were performed on the tiles to an absorbed heat flux of 5 MW/m 2 and surface temperatures near 300 degrees C using 1.4 MPa water at 5.0 m/s flow velocity and an inlet temperature of 8-15 degrees C. One tile was exposed to incrementally increasing heat fluxes up to 9.5 MW/m 2 and surface temperatures up to 690 degrees C before debonding at 10 MW/m 2 . A third tile debonded after 9200 thermal fatigue cycles at 5 MW/m 2 , while another debonded after 6800 cycles. In all cases, fatigue failure occurred in the intermetallic layers between the beryllium and copper. No fatigue cracking of the bulk beryllium was observed. During thermal cycling, a gradual loss of porous coating produced increasing sample temperatures. These experiments indicate that diffusion-bonded beryllium tiles can survive several thousand thermal cycles under ITER relevant conditions without failure. However, the reliability of the diffusion bonded Joint remains a serious issue

  8. Test-retest reliability of infant event related potentials evoked by faces.

    Science.gov (United States)

    Munsters, N M; van Ravenswaaij, H; van den Boomen, C; Kemner, C

    2017-04-05

    Reliable measures are required to draw meaningful conclusions regarding developmental changes in longitudinal studies. Little is known, however, about the test-retest reliability of face-sensitive event related potentials (ERPs), a frequently used neural measure in infants. The aim of the current study is to investigate the test-retest reliability of ERPs typically evoked by faces in 9-10 month-old infants. The infants (N=31) were presented with neutral, fearful and happy faces that contained only the lower or higher spatial frequency information. They were tested twice within two weeks. The present results show that the test-retest reliability of the face-sensitive ERP components is moderate (P400 and Nc) to substantial (N290). However, there is low test-retest reliability for the effects of the specific experimental manipulations (i.e. emotion and spatial frequency) on the face-sensitive ERPs. To conclude, in infants the face-sensitive ERP components (i.e. N290, P400 and Nc) show adequate test-retest reliability, but not the effects of emotion and spatial frequency on these ERP components. We propose that further research focuses on investigating elements that might increase the test-retest reliability, as adequate test-retest reliability is necessary to draw meaningful conclusions on individual developmental trajectories of the face-sensitive ERPs in infants. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  9. Advanced Testing Method for Ground Thermal Conductivity

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xiaobing [ORNL; Clemenzi, Rick [Geothermal Design Center Inc.; Liu, Su [University of Tennessee (UT)

    2017-04-01

    A new method is developed that can quickly and more accurately determine the effective ground thermal conductivity (GTC) based on thermal response test (TRT) results. Ground thermal conductivity is an important parameter for sizing ground heat exchangers (GHEXs) used by geothermal heat pump systems. The conventional GTC test method usually requires a TRT for 48 hours with a very stable electric power supply throughout the entire test. In contrast, the new method reduces the required test time by 40%–60% or more, and it can determine GTC even with an unstable or intermittent power supply. Consequently, it can significantly reduce the cost of GTC testing and increase its use, which will enable optimal design of geothermal heat pump systems. Further, this new method provides more information about the thermal properties of the GHEX and the ground than previous techniques. It can verify the installation quality of GHEXs and has the potential, if developed, to characterize the heterogeneous thermal properties of the ground formation surrounding the GHEXs.

  10. A Reliability Test of a Complex System Based on Empirical Likelihood

    OpenAIRE

    Zhou, Yan; Fu, Liya; Zhang, Jun; Hui, Yongchang

    2016-01-01

    To analyze the reliability of a complex system described by minimal paths, an empirical likelihood method is proposed to solve the reliability test problem when the subsystem distributions are unknown. Furthermore, we provide a reliability test statistic of the complex system and extract the limit distribution of the test statistic. Therefore, we can obtain the confidence interval for reliability and make statistical inferences. The simulation studies also demonstrate the theorem results.

  11. Reliability Generalization of the Alcohol Use Disorder Identification Test.

    Science.gov (United States)

    Shields, Alan L.; Caruso, John C.

    2002-01-01

    Evaluated the reliability of scores from the Alcohol Use Disorders Identification Test (AUDIT; J. Sounders and others, 1993) in a reliability generalization study based on 17 empirical journal articles. Results show AUDIT scores to be generally reliable for basic assessment. (SLD)

  12. Comparative thermal cyclic testing and strength investigation of different Be/Cu joints

    Energy Technology Data Exchange (ETDEWEB)

    Gervash, A.; Giniyatulin, R.; Komarov, V.; Mazul, I.; Litunovsky, N. [Research Inst. of Electrophysical Apparatus, St. Petersburg (Russian Federation); Ganenko, A.; Vainerman, A. [CRISM `Prometey`, 193167, St. Petersburg (Russian Federation); Fedotov, V. [Moscow Physical Engineering Institute, 123060, Moscow (Russian Federation); Davydov, D. [Bochvar Institute, 123060, Moscow (Russian Federation); Zalavutdinov, R. [Institute of Physical Chemistry, Moscow (Russian Federation)

    1998-09-01

    One of the main problems for ITER divertor target technology is to provide a reliable joint between Be as armour material and copper alloy heat-sink structure. Such joints are to satisfy numerous requirements. In particular these joints should successfully withstand cyclic hear fluxes and should have good properties after neutron irradiation. To study such a complex problem, several investigation stages were planed in Russia. This paper presents the results of comparative thermal cyclic testing of different Be/Cu candidates. Summarising the thermal cyclic test results and analysing the metallography of those joints it was found that the life-time of all tested joints is limited by rather thick brittle intermetallic layers in the bonding zone caused by relatively long brazing time using heating and cooling down in traditional ohmic furnace. This paper thus presents attempts of using a unique brazing technique with fast e-beam heating. Metallographic investigation as well as X-ray spectrometric analysis of joints produced using the new technique were done. The recent results of testing of Be/Cu joints produced by fast e-beam brazing are discussed and some ideas for the nearest future investigations are presented. (orig.) 5 refs.

  13. Comparative thermal cyclic testing and strength investigation of different Be/Cu joints

    International Nuclear Information System (INIS)

    Gervash, A.; Giniyatulin, R.; Komarov, V.; Mazul, I.; Litunovsky, N.; Ganenko, A.; Vainerman, A.; Fedotov, V.; Davydov, D.; Zalavutdinov, R.

    1998-01-01

    One of the main problems for ITER divertor target technology is to provide a reliable joint between Be as armour material and copper alloy heat-sink structure. Such joints are to satisfy numerous requirements. In particular these joints should successfully withstand cyclic hear fluxes and should have good properties after neutron irradiation. To study such a complex problem, several investigation stages were planed in Russia. This paper presents the results of comparative thermal cyclic testing of different Be/Cu candidates. Summarising the thermal cyclic test results and analysing the metallography of those joints it was found that the life-time of all tested joints is limited by rather thick brittle intermetallic layers in the bonding zone caused by relatively long brazing time using heating and cooling down in traditional ohmic furnace. This paper thus presents attempts of using a unique brazing technique with fast e-beam heating. Metallographic investigation as well as X-ray spectrometric analysis of joints produced using the new technique were done. The recent results of testing of Be/Cu joints produced by fast e-beam brazing are discussed and some ideas for the nearest future investigations are presented. (orig.)

  14. Test re-test reliability and construct validity of the star-track test of manual dexterity

    DEFF Research Database (Denmark)

    Kildebro, Niels; Amirian, Ilda; Gögenur, Ismail

    2015-01-01

    Objectives. We wished to determine test re-test reliability and construct validity of the star-track test of manual dexterity. Design. Test re-test reliability was examined in a controlled study. Construct validity was tested in a blinded randomized crossover study. Setting. The study was performed...... at a university hospital in Denmark. Participants. A total of 11 subjects for test re-test and 20 subjects for the construct validity study were included. All subjects were healthy volunteers. Intervention. The test re-test trial had two measurements with 2 days pause in between. The interventions...... in the construct validity study included baseline measurement, intervention 1: fatigue, intervention 2: stress, and intervention 3: fatigue and stress. There was a 2 day pause between each intervention. Main outcome measure. An integrated measure of completion time and number of errors was used. Results. All...

  15. Test-retest reliability and predictive validity of the Implicit Association Test in children.

    Science.gov (United States)

    Rae, James R; Olson, Kristina R

    2018-02-01

    The Implicit Association Test (IAT) is increasingly used in developmental research despite minimal evidence of whether children's IAT scores are reliable across time or predictive of behavior. When test-retest reliability and predictive validity have been assessed, the results have been mixed, and because these studies have differed on many factors simultaneously (lag-time between testing administrations, domain, etc.), it is difficult to discern what factors may explain variability in existing test-retest reliability and predictive validity estimates. Across five studies (total N = 519; ages 6- to 11-years-old), we manipulated two factors that have varied in previous developmental research-lag-time and domain. An internal meta-analysis of these studies revealed that, across three different methods of analyzing the data, mean test-retest (rs of .48, .38, and .34) and predictive validity (rs of .46, .20, and .10) effect sizes were significantly greater than zero. While lag-time did not moderate the magnitude of test-retest coefficients, whether we observed domain differences in test-retest reliability and predictive validity estimates was contingent on other factors, such as how we scored the IAT or whether we included estimates from a unique sample (i.e., a sample containing gender typical and gender diverse children). Recommendations are made for developmental researchers that utilize the IAT in their research. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  16. Test Re-Test Reliability of Four Versions of the 3-Cone Test in Non-Athletic Men

    Directory of Open Access Journals (Sweden)

    Jason G. Langley, Robert D. Chetlin

    2017-03-01

    Full Text Available Until recently, measurement and evaluation in sport science, especially agility testing, has not always included key elements of proper test construction. Often tests are published without reporting reliability and validity analysis for a specific population. The purpose of the present study was to examine the test re-test reliability of four versions of the 3-Cone Test (3CT, and provide guidance on proper test construction for testing agility in athletic populations. Forty male students enrolled in classes in the Department of Physical Education at a mid-Atlantic university participated. On each of test day participants performed 10 trials. In random order, they performed three trials to the right (3CTR, standard test, three to the left (3CTL, and two modified trials (3CTAR and 3CTAL, which included a reactive component in which a visual cue was given to indicate direction. Intra-class correlation coefficients (ICC indicated a moderate to high reliability for the four tests, 3CTR 0.79 (0.64-0.88, 95%CI, 3CTL 0.73 (0.55-0.85, 3CTAR 0.85(0.74-0.92, and 3CTAL 0.79 (0.64-0.88. Small standard error of the measurement (SEM was found; range 0.09 to 0.10. Pearson correlations between tests were high (0.82-0.92 on day one as well as day two (0.72-0.85. These results indicate each version of the 3-Cone Test is reliable; however, further tests are needed with specific athletic populations. Only the 3CTAR and 3CTAL are tests of agility due to the inclusion of a reactive component. Future studies examining agility testing and training should incorporate technological elements, including automated timing systems and motion capture analysis. Such instrumentation will allow for optimal design of tests that simulate sport-specific game conditions.

  17. A study on thermal ratcheting structure test of 316L test cylinder

    International Nuclear Information System (INIS)

    Lee, H. Y.; Kim, J. B.; Koo, G. H.

    2001-01-01

    In this study, the progressive inelastic deformation, so called, thermal ratchet phenomenon which can occur in high temperature liquid metal reactor was simulated with thermal ratchet structural test facility and 316L stainless steel test cylinder. The inelastic deformation of the reactor baffle cylinder can occur due to the moving temperature distribution along the axial direction as the hot free surface moves up and down under the cyclic heat-up and cool-down of reactor operations. The ratchet deformations were measured with the laser displacement sensor and LVDTs after cooling the structural specimen which experiences thermal load up to 550 .deg. C and the temperature differences of about 500 .deg. C. During structural thermal ratchet test, the temperature distribution of the test cylinder along the axial direction was measured from 28 channels of thermocouples and the temperatures were used for the ratchet analysis. The thermal ratchet deformation analysis was performed with the NONSTA code whose constitutive model is nonlinear combined kinematic and isotropic hardening model and the test results were compared with those of the analysis. Thermal ratchet test was carried out with respect to 9 cycles of thermal loading and the maximum residual displacements were measured to be 1.8mm. It was shown that thermal ratchet load can cause a progressive deformation to the reactor structure. The analysis results with the combined hardening model were in reasonable agreement with those of the tests

  18. Open stack thermal battery tests

    Energy Technology Data Exchange (ETDEWEB)

    Long, Kevin N. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Roberts, Christine C. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Grillet, Anne M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Headley, Alexander J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Fenton, Kyle [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Wong, Dennis [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Ingersoll, David [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-04-17

    We present selected results from a series of Open Stack thermal battery tests performed in FY14 and FY15 and discuss our findings. These tests were meant to provide validation data for the comprehensive thermal battery simulation tools currently under development in Sierra/Aria under known conditions compared with as-manufactured batteries. We are able to satisfy this original objective in the present study for some test conditions. Measurements from each test include: nominal stack pressure (axial stress) vs. time in the cold state and during battery ignition, battery voltage vs. time against a prescribed current draw with periodic pulses, and images transverse to the battery axis from which cell displacements are computed. Six battery configurations were evaluated: 3, 5, and 10 cell stacks sandwiched between 4 layers of the materials used for axial thermal insulation, either Fiberfrax Board or MinK. In addition to the results from 3, 5, and 10 cell stacks with either in-line Fiberfrax Board or MinK insulation, a series of cell-free “control” tests were performed that show the inherent settling and stress relaxation based on the interaction between the insulation and heat pellets alone.

  19. Materials selection for long life in LEO: a critical evaluation of atomic oxygen testing with thermal atom systems

    International Nuclear Information System (INIS)

    Koontz, S.L.; Kuminecz, J.; Leger, L.; Nordine, P.

    1988-01-01

    The use of thermal atom test methods as a materials selection and screening technique for low-Earth orbit (LEO) spacecraft is critically evaluated. The chemistry and physics of thermal atom environments are compared with the LEO environment. The relative reactivities of a number of materials determined to be in thermal atom environments are compared to those observed in LEO and in high quality LEO simulations. Reaction efficiencies measured in a new type of thermal atom apparatus are one-hundredth to one-thousandth those observed in LEO, and many materials showing nearly identical reactivities in LEO show relative reactivities differing by as much as a factor of 8 in thermal atom systems. A simple phenomenological kinetic model for the reaction of oxygen atoms with organic materials can be used to explain the differences in reactivity in different environments. Certain specific thermal test environments can be used as reliable materials screening tools. Using thermal atom methods to predict material lifetime in LEO requires direct calibration of the method against LEO data or high quality simulation data for each material

  20. Automation of testing the metrological reliability of nondestructive control systems

    International Nuclear Information System (INIS)

    Zhukov, Yu.A.; Isakov, V.B.; Karlov, Yu.K.; Kovalevskij, Yu.A.

    1987-01-01

    Opportunities of microcomputers are used to solve the problem of testing control-measuring systems. Besides the main program the program of data processing when characterizing the nondestructive control systems is written in the microcomputer. The program includes two modules. The first module contains tests-programs, by which accuracy of functional elements of the microcomputer and interface elements with issuing a message to the operator on readiness of the elements for operation and failure of a certain element are determined. The second module includes: calculational programs when determining metrological reliability of measuring channel reliability, a calculational subprogram for random statistical measuring error, time instability and ''dead time''. Automation of testing metrological reliability of the nondestructive control systems increases reliability of determining metrological parameters and reduces time of system testing

  1. Reliability tests for reactor internals replacement technology

    International Nuclear Information System (INIS)

    Fujimaki, K.; Uchiyama, J.; Ohtsubo, T.

    2000-01-01

    Structural damage due to aging degradation of LWR reactor internals has been reported in several nuclear plants. NUPEC has started a project to test the reliability of the technology for replacing reactor internals, which was directed at preventive maintenance before damage and repair after damage for the aging degradation. The project has been funded by the Ministry of International Trade and Industry (MITI) of Japan since 1995, and it follows the policy of a report that the MITI has formally issued in April 1996 summarizing the countermeasures to be considered for aging nuclear plants and equipment. This paper gives an outline of the whole test plans and the test results for the BWR reactor internals replacement methods; core shroud, ICM housing, and CRD Housing and stub tube. The test results have shown that the methods were reliable and the structural integrity was appropriate based on the evaluation. (author)

  2. Test-retest reliability of a balance testing protocol with external perturbations in young healthy adults.

    Science.gov (United States)

    Robbins, Shawn M; Caplan, Ryan M; Aponte, Daniel I; St-Onge, Nancy

    2017-10-01

    External perturbations are utilized to challenge balance and mimic realistic balance threats in patient populations. The reliability of such protocols has not been established. The purpose was to examine test-retest reliability of balance testing with external perturbations. Healthy adults (n=34; mean age 23 years) underwent balance testing over two visits. Participants completed ten balance conditions in which the following parameters were combined: perturbation or non-perturbation, single or double leg, and eyes open or closed. Three trials were collected for each condition. Data were collected on a force plate and external perturbations were applied by translating the plate. Force plate center of pressure (CoP) data were summarized using 13 different CoP measures. Test-retest reliability was examined using intraclass correlation coefficients (ICC) and Bland-Altman plots. CoP measures of total speed and excursion in both anterior-posterior and medial-lateral directions generally had acceptable ICC values for perturbation conditions (ICC=0.46 to 0.87); however, many other CoP measures (e.g. range, area of ellipse) had unacceptable test-retest reliability (ICCbalance testing protocols that include external perturbations should be made to improve test-retest reliability and diminish learning including more extensive participant training and increasing the number of trials. CoP measures that consider all data points (e.g. total speed) are more reliable than those that only consider a few data points. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. National Solar Thermal Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The National Solar Thermal Test Facility (NSTTF) is the only test facility in the United States of its type. This unique facility provides experimental engineering...

  4. Test-retest reliability for aerodynamic measures of voice.

    Science.gov (United States)

    Awan, Shaheen N; Novaleski, Carolyn K; Yingling, Julie R

    2013-11-01

    The purpose of this study was to investigate the intrasubject reliability of aerodynamic characteristics of the voice within typical/normal speakers across testing sessions using the Phonatory Aerodynamic System (PAS 6600; KayPENTAX, Montvale, NJ). Participants were 60 healthy young adults (30 males and 30 females) between the ages 18 and 31 years with perceptually typical voice. Participants were tested using the PAS 6600 (Phonatory Aerodynamic System) on two separate days with approximately 1 week between each session at approximately the same time of day. Four PAS protocols were conducted (vital capacity, maximum sustained phonation, comfortable sustained phonation, and voicing efficiency) and measures of expiratory volume, maximum phonation time, mean expiratory airflow (during vowel production) and target airflow (obtained via syllable repetition), peak air pressure, aerodynamic power, aerodynamic resistance, and aerodynamic efficiency were obtained during each testing session. Associated acoustic measures of vocal intensity and frequency were also collected. All phonations were elicited at comfortable pitch and loudness. All aerodynamic and associated variables evaluated in this study showed useable test-retest reliability (ie, intraclass correlation coefficients [ICCs] ≥ 0.60). A high degree of mean test-retest reliability was found across all subjects for aerodynamic and associated acoustic measurements of vital capacity, maximum sustained phonation, glottal resistance, and vocal intensity (all with ICCs > 0.75). Although strong ICCs were observed for measures of glottal power and mean expiratory airflow in males, weaker overall results for these measures (ICC range: 0.60-0.67) were observed in females subjects and sizable coefficients of variation were observed for measures of power, resistance, and efficiency in both men and women. Differences in degree of reliability from measure to measure were revealed in greater detail using methods such as ICCs and

  5. Test-retest reliability and validity of the Sniffin' TOM odor memory test.

    Science.gov (United States)

    Croy, Ilona; Zehner, Cora; Larsson, Maria; Zucco, Gesualdo M; Hummel, Thomas

    2015-03-01

    Few attempts have been made to develop an olfactory test that captures episodic retention of olfactory information. Assessment of episodic odor memory is of particular interest in aging and in the cognitively impaired as both episodic memory deficits and olfactory loss have been targeted as reliable hallmarks of cognitive decline and impending dementia. Here, 96 healthy participants (18-92 years) and an additional 19 older people with mild cognitive impairment were tested (73-82 years). Participants were presented with 8 common odors with intentional encoding instructions that were followed by a yes-no recognition test. After recognition completion, participants were asked to identify all odors by means of free or cued identification. A retest of the odor memory test (Sniffin' TOM = test of odor memory) took place 17 days later. The results revealed satisfactory test-retest reliability (0.70) of odor recognition memory. Both recognition and identification performance were negatively affected by age and more pronounced among the cognitively impaired. In conclusion, the present work presents a reliable, valid, and simple test of episodic odor recognition memory that may be used in clinical groups where both episodic memory deficits and olfactory loss are prevalent preclinically such as Alzheimer's disease. © The Author 2014. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  6. Determining the theoretical reliability function of thermal power system using simple and complex Weibull distribution

    Directory of Open Access Journals (Sweden)

    Kalaba Dragan V.

    2014-01-01

    Full Text Available The main subject of this paper is the representation of the probabilistic technique for thermal power system reliability assessment. Exploitation research of the reliability of the fossil fuel power plant system has defined the function, or the probabilistic law, according to which the random variable behaves (occurrence of complete unplanned standstill. Based on these data, and by applying the reliability theory to this particular system, using simple and complex Weibull distribution, a hypothesis has been confirmed that the distribution of the observed random variable fully describes the behaviour of such a system in terms of reliability. Establishing a comprehensive insight in the field of probabilistic power system reliability assessment technique could serve as an input for further research and development in the area of power system planning and operation.

  7. Below-Ambient and Cryogenic Thermal Testing

    Science.gov (United States)

    Fesmire, James E.

    2016-01-01

    Thermal insulation systems operating in below-ambient temperature conditions are inherently susceptible to moisture intrusion and vapor drive toward the cold side. The subsequent effects may include condensation, icing, cracking, corrosion, and other problems. Methods and apparatus for real-world thermal performance testing of below-ambient systems have been developed based on cryogenic boiloff calorimetry. New ASTM International standards on cryogenic testing and their extension to future standards for below-ambient testing of pipe insulation are reviewed.

  8. Models on reliability of non-destructive testing

    International Nuclear Information System (INIS)

    Simola, K.; Pulkkinen, U.

    1998-01-01

    The reliability of ultrasonic inspections has been studied in e.g. international PISC (Programme for the Inspection of Steel Components) exercises. These exercises have produced a large amount of information on the effect of various factors on the reliability of inspections. The information obtained from reliability experiments are used to model the dependency of flaw detection probability on various factors and to evaluate the performance of inspection equipment, including the sizing accuracy. The information from experiments is utilised in a most effective way when mathematical models are applied. Here, some statistical models for reliability of non-destructive tests are introduced. In order to demonstrate the use of inspection reliability models, they have been applied to the inspection results of intergranular stress corrosion cracking (IGSCC) type flaws in PISC III exercise (PISC 1995). The models are applied to both flaw detection frequency data of all inspection teams and to flaw sizing data of one participating team. (author)

  9. Enabling More than Moore: Accelerated Reliability Testing and Risk Analysis for Advanced Electronics Packaging

    Science.gov (United States)

    Ghaffarian, Reza; Evans, John W.

    2014-01-01

    For five decades, the semiconductor industry has distinguished itself by the rapid pace of improvement in miniaturization of electronics products-Moore's Law. Now, scaling hits a brick wall, a paradigm shift. The industry roadmaps recognized the scaling limitation and project that packaging technologies will meet further miniaturization needs or ak.a "More than Moore". This paper presents packaging technology trends and accelerated reliability testing methods currently being practiced. Then, it presents industry status on key advanced electronic packages, factors affecting accelerated solder joint reliability of area array packages, and IPC/JEDEC/Mil specifications for characterizations of assemblies under accelerated thermal and mechanical loading. Finally, it presents an examples demonstrating how Accelerated Testing and Analysis have been effectively employed in the development of complex spacecraft thereby reducing risk. Quantitative assessments necessarily involve the mathematics of probability and statistics. In addition, accelerated tests need to be designed which consider the desired risk posture and schedule for particular project. Such assessments relieve risks without imposing additional costs. and constraints that are not value added for a particular mission. Furthermore, in the course of development of complex systems, variances and defects will inevitably present themselves and require a decision concerning their disposition, necessitating quantitative assessments. In summary, this paper presents a comprehensive view point, from technology to systems, including the benefits and impact of accelerated testing in offsetting risk.

  10. 40 CFR 90.329 - Catalyst thermal stress test.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Catalyst thermal stress test. 90.329... Equipment Provisions § 90.329 Catalyst thermal stress test. (a) Oven characteristics. The oven used for thermally stressing the test catalyst must be capable of maintaining a temperature of 500 ±5 °C and 1000 ±10...

  11. Forward lunge as a functional performance test in ACL deficient subjects: test-retest reliability

    DEFF Research Database (Denmark)

    Alkjaer, Tine; Henriksen, Marius; Dyhre-Poulsen, Poul

    2009-01-01

    The forward lunge movement may be used as a functional performance test of anterior cruciate ligament (ACL) deficient and reconstructed subjects. The purposes were 1) to determine the test-retest reliability of a forward lunge in healthy subjects and 2) to determine the required numbers...... of repetitions necessary to yield satisfactory reliability. Nineteen healthy subjects performed four trials of a forward lunge on two different days. The movement time, impulses of the ground reaction forces (IFz, IFy), knee joint kinematics and dynamics during the forward lunge were calculated. The relative...... reliability was determined by calculation of Intraclass Correlation Coefficients (ICC). The IFz, IFy and the positive work of the knee extensors showed excellent reliability (ICC >0.75). All other variables demonstrated acceptable reliability (0.4>ICCreliability increased when more than...

  12. Mars Science Laboratory Rover System Thermal Test

    Science.gov (United States)

    Novak, Keith S.; Kempenaar, Joshua E.; Liu, Yuanming; Bhandari, Pradeep; Dudik, Brenda A.

    2012-01-01

    On November 26, 2011, NASA launched a large (900 kg) rover as part of the Mars Science Laboratory (MSL) mission to Mars. The MSL rover is scheduled to land on Mars on August 5, 2012. Prior to launch, the Rover was successfully operated in simulated mission extreme environments during a 16-day long Rover System Thermal Test (STT). This paper describes the MSL Rover STT, test planning, test execution, test results, thermal model correlation and flight predictions. The rover was tested in the JPL 25-Foot Diameter Space Simulator Facility at the Jet Propulsion Laboratory (JPL). The Rover operated in simulated Cruise (vacuum) and Mars Surface environments (8 Torr nitrogen gas) with mission extreme hot and cold boundary conditions. A Xenon lamp solar simulator was used to impose simulated solar loads on the rover during a bounding hot case and during a simulated Mars diurnal test case. All thermal hardware was exercised and performed nominally. The Rover Heat Rejection System, a liquid-phase fluid loop used to transport heat in and out of the electronics boxes inside the rover chassis, performed better than predicted. Steady state and transient data were collected to allow correlation of analytical thermal models. These thermal models were subsequently used to predict rover thermal performance for the MSL Gale Crater landing site. Models predict that critical hardware temperatures will be maintained within allowable flight limits over the entire 669 Sol surface mission.

  13. Reliability tests for reactor internals rejuvenation technology

    International Nuclear Information System (INIS)

    Fujimaki, Katsumi; Hitoki, Yoichi; Otsubo, Toru; Uchiyama, Junichi

    1998-01-01

    Structural damage due to aging degradation of LWR reactor internals has been reported in several nuclear plants. NUPEC has started a project to test the reliability of the technology for rejuvenating reactor internals which has been funded by the Ministry of International Trade and Industry (MITI) of Japan since 1995. The project follows the policy of a report that the MITI has formally issued in April 1996 summarizing the countermeasures to be considered for aging nuclear plants and equipment. This paper gives an outline of the test plans and results which are directed at preventive maintenance before damage and repair after damage for reactor internals aging degradation. The test results for the replacement methods of ICM housing and BWR core shroud have shown that the methods were reliable and the structural integrity was appropriate based on the evaluation. (author)

  14. Validity and Reliability of the Arabic Token Test for Children

    Science.gov (United States)

    Alkhamra, Rana A.; Al-Jazi, Aya B.

    2016-01-01

    Background: The Token Test for Children (2nd edition) (TTFC) is a measure for assessing receptive language. In this study we describe the translation process, validity and reliability of the Arabic Token Test for Children (A-TTFC). Aims: The aim of this study is to translate, validate and establish the reliability of the Arabic Token Test for…

  15. Conceptualizing Essay Tests' Reliability and Validity: From Research to Theory

    Science.gov (United States)

    Badjadi, Nour El Imane

    2013-01-01

    The current paper on writing assessment surveys the literature on the reliability and validity of essay tests. The paper aims to examine the two concepts in relationship with essay testing as well as to provide a snapshot of the current understandings of the reliability and validity of essay tests as drawn in recent research studies. Bearing in…

  16. Construction of Valid and Reliable Test for Assessment of Students

    Science.gov (United States)

    Osadebe, P. U.

    2015-01-01

    The study was carried out to construct a valid and reliable test in Economics for secondary school students. Two research questions were drawn to guide the establishment of validity and reliability for the Economics Achievement Test (EAT). It is a multiple choice objective test of five options with 100 items. A sample of 1000 students was randomly…

  17. In-situ thermal testing program strategy

    International Nuclear Information System (INIS)

    1995-06-01

    In the past year the Yucca Mountain Site Characterization Project has implemented a new Program Approach to the licensing process. The Program Approach suggests a step-wise approach to licensing in which the early phases will require less site information than previously planned and necessitate a lesser degree of confidence in the longer-term performance of the repository. Under the Program Approach, the thermal test program is divided into two principal phases: (1) short-term in situ tests (in the 1996 to 2000 time period) and laboratory thermal tests to obtain preclosure information, parameters, and data along with bounding information for postclosure performance; and (2) longer-term in situ tests to obtain additional data regarding postclosure performance. This effort necessitates a rethinking of the testing program because the amount of information needed for the initial licensing phase is less than previously planned. This document proposes a revised and consolidated in situ thermal test program (including supporting laboratory tests) that is structured to meet the needs of the Program Approach. A customer-supplier model is used to define the Project data needs. These data needs, along with other requirements, were then used to define a set of conceptual experiments that will provide the required data within the constraints of the Program Approach schedule. The conceptual thermal tests presented in this document represent a consolidation and update of previously defined tests that should result in a more efficient use of Project resources. This document focuses on defining the requirements and tests needed to satisfy the goal of a successful license application in 2001, should the site be found suitable

  18. Inter-tester reliability of selected clinical tests for long-lasting temporomandibular disorders.

    Science.gov (United States)

    Julsvoll, Elisabeth Heggem; Vøllestad, Nina Køpke; Opseth, Gro; Robinson, Hilde Stendal

    2017-09-01

    Clinical tests used to examine patients with temporomandibular disorders vary in methodological quality, and some are not tested for reliability. The purpose of this cross-sectional study was to evaluate inter-tester reliability of clinical tests and a cluster of tests used to examine patients with long-lasting temporomandibular disorders. Forty patients with pain in the temporomandibular area treated by health-professionals were included. They were between 18-70 years, had 65 symptomatic (33 right/32 left) and 15 asymptomatic joints. Two manual therapists examined all participants with selected tests. Percentage agreement and the kappa coefficient ( k ) with 95% confidence interval (CI) were used to evaluate the tests with categorical outcomes. For tests with continuous outcomes, the relative inter-tester reliability was assessed by the intraclass-correlation-coefficient (ICC 3,1 , 95% CI) and the absolute reliability was calculated by the smallest detectable change (SDC). The best reliability among single tests was found for the dental stick test, the joint-sound test ( k  = 0.80-1.0) and range of mouth-opening (ICC 3,1 (95% CI) = 0.97 (0.95-0.98) and SDC = 4 mm). The reliability of cluster of tests was excellent with both four and five positive tests out of seven. The reliability was good to excellent for the clinical tests and the cluster of tests when performed by experienced therapists. The tests are feasible for use in the clinical setting. They require no advanced equipment and are easy to perform.

  19. MEMS Reliability: Infrastructure, Test Structures, Experiments, and Failure Modes

    Energy Technology Data Exchange (ETDEWEB)

    TANNER,DANELLE M.; SMITH,NORMAN F.; IRWIN,LLOYD W.; EATON,WILLIAM P.; HELGESEN,KAREN SUE; CLEMENT,J. JOSEPH; MILLER,WILLIAM M.; MILLER,SAMUEL L.; DUGGER,MICHAEL T.; WALRAVEN,JEREMY A.; PETERSON,KENNETH A.

    2000-01-01

    The burgeoning new technology of Micro-Electro-Mechanical Systems (MEMS) shows great promise in the weapons arena. We can now conceive of micro-gyros, micro-surety systems, and micro-navigators that are extremely small and inexpensive. Do we want to use this new technology in critical applications such as nuclear weapons? This question drove us to understand the reliability and failure mechanisms of silicon surface-micromachined MEMS. Development of a testing infrastructure was a crucial step to perform reliability experiments on MEMS devices and will be reported here. In addition, reliability test structures have been designed and characterized. Many experiments were performed to investigate failure modes and specifically those in different environments (humidity, temperature, shock, vibration, and storage). A predictive reliability model for wear of rubbing surfaces in microengines was developed. The root causes of failure for operating and non-operating MEMS are discussed. The major failure mechanism for operating MEMS was wear of the polysilicon rubbing surfaces. Reliability design rules for future MEMS devices are established.

  20. Reliability of Computerized Neurocognitive Tests for Concussion Assessment: A Meta-Analysis.

    Science.gov (United States)

    Farnsworth, James L; Dargo, Lucas; Ragan, Brian G; Kang, Minsoo

    2017-09-01

      Although widely used, computerized neurocognitive tests (CNTs) have been criticized because of low reliability and poor sensitivity. A systematic review was published summarizing the reliability of Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) scores; however, this was limited to a single CNT. Expansion of the previous review to include additional CNTs and a meta-analysis is needed. Therefore, our purpose was to analyze reliability data for CNTs using meta-analysis and examine moderating factors that may influence reliability.   A systematic literature search (key terms: reliability, computerized neurocognitive test, concussion) of electronic databases (MEDLINE, PubMed, Google Scholar, and SPORTDiscus) was conducted to identify relevant studies.   Studies were included if they met all of the following criteria: used a test-retest design, involved at least 1 CNT, provided sufficient statistical data to allow for effect-size calculation, and were published in English.   Two independent reviewers investigated each article to assess inclusion criteria. Eighteen studies involving 2674 participants were retained. Intraclass correlation coefficients were extracted to calculate effect sizes and determine overall reliability. The Fisher Z transformation adjusted for sampling error associated with averaging correlations. Moderator analyses were conducted to evaluate the effects of the length of the test-retest interval, intraclass correlation coefficient model selection, participant demographics, and study design on reliability. Heterogeneity was evaluated using the Cochran Q statistic.   The proportion of acceptable outcomes was greatest for the Axon Sports CogState Test (75%) and lowest for the ImPACT (25%). Moderator analyses indicated that the type of intraclass correlation coefficient model used significantly influenced effect-size estimates, accounting for 17% of the variation in reliability.   The Axon Sports CogState Test, which

  1. Effects of voids on thermal-mechanical reliability of lead-free solder joints

    Directory of Open Access Journals (Sweden)

    Benabou Lahouari

    2014-06-01

    Full Text Available Reliability of electronic packages has become a major issue, particularly in systems used in electrical or hybrid cars where severe operating conditions must be met. Many studies have shown that solder interconnects are critical elements since many failure mechanisms originate from their typical response under thermal cycles. In this study, effects of voids in solder interconnects on the electronic assembly lifetime are estimated based on finite element simulations.

  2. Test-Retest Reliability of the Short-Form Survivor Unmet Needs Survey.

    Science.gov (United States)

    Taylor, Karen; Bulsara, Max; Monterosso, Leanne

    2018-01-01

    Reliable and valid needs assessment measures are important assessment tools in cancer survivorship care. A new 30-item short-form version of the Survivor Unmet Needs Survey (SF-SUNS) was developed and validated with cancer survivors, including hematology cancer survivors; however, test-retest reliability has not been established. The objective of this study was to assess the test-retest reliability of the SF-SUNS with a cohort of lymphoma survivors ( n = 40). Test-retest reliability of the SF-SUNS was conducted at two time points: baseline (time 1) and 5 days later (time 2). Test-retest data were collected from lymphoma cancer survivors ( n = 40) in a large tertiary cancer center in Western Australia. Intraclass correlation analyses compared data at time 1 (baseline) and time 2 (5 days later). Cronbach's alpha analyses were performed to assess the internal consistency at both time points. The majority (23/30, 77%) of items achieved test-retest reliability scores 0.45-0.74 (fair to good). A high degree of overall internal consistency was demonstrated (time 1 = 0.92, time 2 = 0.95), with scores 0.65-0.94 across subscales for both time points. Mixed test-retest reliability of the SF-SUNS was established. Our results indicate the SF-SUNS is responsive to the changing needs of lymphoma cancer survivors. Routine use of cancer survivorship specific needs-based assessments is required in oncology care today. Nurses are well placed to administer these assessments and provide tailored information and resources. Further assessment of test-retest reliability in hematology and other cancer cohorts is warranted.

  3. Validity and Reliability of Baseline Testing in a Standardized Environment.

    Science.gov (United States)

    Higgins, Kathryn L; Caze, Todd; Maerlender, Arthur

    2017-08-11

    The Immediate Postconcussion Assessment and Cognitive Testing (ImPACT) is a computerized neuropsychological test battery commonly used to determine cognitive recovery from concussion based on comparing post-injury scores to baseline scores. This model is based on the premise that ImPACT baseline test scores are a valid and reliable measure of optimal cognitive function at baseline. Growing evidence suggests that this premise may not be accurate and a large contributor to invalid and unreliable baseline test scores may be the protocol and environment in which baseline tests are administered. This study examined the effects of a standardized environment and administration protocol on the reliability and performance validity of athletes' baseline test scores on ImPACT by comparing scores obtained in two different group-testing settings. Three hundred-sixty one Division 1 cohort-matched collegiate athletes' baseline data were assessed using a variety of indicators of potential performance invalidity; internal reliability was also examined. Thirty-one to thirty-nine percent of the baseline cases had at least one indicator of low performance validity, but there were no significant differences in validity indicators based on environment in which the testing was conducted. Internal consistency reliability scores were in the acceptable to good range, with no significant differences between administration conditions. These results suggest that athletes may be reliably performing at levels lower than their best effort would produce. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  4. Re-test reliability of gustatory testing and introduction of the sensitive Taste-Drop-Test

    DEFF Research Database (Denmark)

    Fjaeldstad, A; Niklassen, A; Fernandes, H

    2018-01-01

    . Testing gustatory function can be important for diagnostics and assessment of treatment effects. However, the gustatory tests applied are required to be both sensitive and reliable.In this study, we investigate the re-test validity of popular Taste Strips gustatory test for gustatory screening....... Furthermore, we introduce a new sensitive Taste-Drop-Test, which was found to be superior for detecting a more accurate measure of tastant sensitivity....

  5. Reliability of the Test of Integrated Language and Literacy Skills (TILLS)

    Science.gov (United States)

    Mailend, Marja-Liisa; Plante, Elena; Anderson, Michele A.; Applegate, E. Brooks; Nelson, Nickola W.

    2016-01-01

    Background: As new standardized tests become commercially available, it is critical that clinicians have access to the information about a test's psychometric properties, including aspects of reliability. Aims: The purpose of the three studies reported in this article was to investigate the reliability of a new test, the Test of Integrated…

  6. Intertester reliability of the talk test in a cardiac rehabilitation population

    DEFF Research Database (Denmark)

    Petersen, Annemette Krintel; Maribo, Thomas; Hjortdal, Vibeke Elisabeth

    2013-01-01

    PURPOSE: The validity of the Talk Test (TT) is well documented, but the reliability of the test is not clear. The aim of this study was to assess the absolute and relative intertester reliability of the TT in cardiac patients. METHODS: Cardiac patients (n = 64) who had completed an exercise...... randomized to tests. Workload in watts at the first negative stage of the TT was registered as the test result. Patients and physiotherapists were blinded to test results of the first test. Absolute reliability of the TT was assessed with Bland-Altman plot, standard error of measurement, and minimal...... detectable change. Relative reliability was assessed using the intraclass correlation coefficient (ICC). RESULTS: Mean difference in peak workload between test and retest was 0.8 W (95% CI: -4.8 to 3.3). Limit of agreement was estimated to be +31/-32 W. Standard error of measurement was 11 W (95% CI: 10...

  7. Test-Retest Reliability of Computerized, Everyday Memory Measures and Traditional Memory Tests.

    Science.gov (United States)

    Youngjohn, James R.; And Others

    Test-retest reliabilities and practice effect magnitudes were considered for nine computer-simulated tasks of everyday cognition and five traditional neuropsychological tests. The nine simulated everyday memory tests were from the Memory Assessment Clinic battery as follows: (1) simple reaction time while driving; (2) divided attention (driving…

  8. Test-retest reliability of the Progressive Isoinertial Lifting Evaluation (PILE).

    Science.gov (United States)

    Lygren, Hildegunn; Dragesund, Tove; Joensen, Jón; Ask, Tove; Moe-Nilssen, Rolf

    2005-05-01

    A repeated measures single group design. To investigate test-retest reliability of Progressive Isoinertial Lifting Evaluation on patients with long lasting musculoskeletal problems related to the lumbar spine. Test-retest reliability has been satisfactory in healthy men. Test-retest reliability for clinical populations has not been reported. A total of 31 patients (17 women and 14 men) with long lasting low back pain participated in the study. The patients were tested twice at an interval of 2 days and at the same time of the day. The heaviest load that the patient could lift 4 times was used as outcome measure. The error of measurement indicates that the true result in 95% of cases will be within +/-4.5 kg from the measured value, while the difference between 2 measurements in 95% of cases will be less than 6.4 kg. Intra-class correlation (1,1) was 0.91. Relative test-retest reliability was high assessed by intra-class correlation, but absolute measurement variability reported as the smallest detectable difference has relevance for the interpretation of clinical test results and should also be considered.

  9. Test-retest reliability of the multifocal photopic negative response.

    Science.gov (United States)

    Van Alstine, Anthony W; Viswanathan, Suresh

    2017-02-01

    To assess the test-retest reliability of the multifocal photopic negative response (mfPhNR) of normal human subjects. Multifocal electroretinograms were recorded from one eye of 61 healthy adult subjects on two separate days using a Visual Evoked Response Imaging System software version 4.3 (EDI, San Mateo, California). The visual stimulus delivered on a 75-Hz monitor consisted of seven equal-sized hexagons each subtending 12° of visual angle. The m-step exponent was 9, and the m-sequence was slowed to include at least 30 blank frames after each flash. Only the first slice of the first-order kernel was analyzed. The mfPhNR amplitude was measured at a fixed time in the trough from baseline (BT) as well as at the same fixed time in the trough from the preceding b-wave peak (PT). Additionally, we also analyzed BT normalized either to PT (BT/PT) or to the b-wave amplitude (BT/b-wave). The relative reliability of test-retest differences for each test location was estimated by the Wilcoxon matched-pair signed-rank test and intraclass correlation coefficients (ICC). Absolute test-retest reliability was estimated by Bland-Altman analysis. The test-retest amplitude differences for neither of the two measurement techniques were statistically significant as determined by Wilcoxon matched-pair signed-rank test. PT measurements showed greater ICC values than BT amplitude measurements for all test locations. For each measurement technique, the ICC value of the macular response was greater than that of the surrounding locations. The mean test-retest difference was close to zero for both techniques at each of the test locations, and while the coefficient of reliability (COR-1.96 times the standard deviation of the test-retest difference) was comparable for the two techniques at each test location when expressed in nanovolts, the %COR (COR normalized to the mean test and retest amplitudes) was superior for PT than BT measurements. The ICC and COR were comparable for the BT/PT and

  10. Power Control and Monitoring Requirements for Thermal Vacuum/Thermal Balance Testing of the MAP Observatory

    Science.gov (United States)

    Johnson, Chris; Hinkle, R. Kenneth (Technical Monitor)

    2002-01-01

    The specific heater control requirements for the thermal vacuum and thermal balance testing of the Microwave Anisotropy Probe (MAP) Observatory at the Goddard Space Flight Center (GSFC) in Greenbelt, Maryland are described. The testing was conducted in the 10m wide x 18.3m high Space Environment Simulator (SES) Thermal Vacuum Facility. The MAP thermal testing required accurate quantification of spacecraft and fixture power levels while minimizing heater electrical emissions. The special requirements of the MAP test necessitated construction of five (5) new heater racks.

  11. Thermal management for LED applications

    CERN Document Server

    Poppe, András

    2014-01-01

    Thermal Management for LED Applications provides state-of-the-art information on recent developments in thermal management as it relates to LEDs and LED-based systems and their applications. Coverage begins with an overview of the basics of thermal management including thermal design for LEDs, thermal characterization and testing of LEDs, and issues related to failure mechanisms and reliability and performance in harsh environments. Advances and recent developments in thermal management round out the book with discussions on advances in TIMs (thermal interface materials) for LED applications, advances in forced convection cooling of LEDs, and advances in heat sinks for LED assemblies. This book also: Presents a comprehensive overview of the basics of thermal management as it relates to LEDs and LED-based systems Discusses both design and thermal management considerations when manufacturing LEDs and LED-based systems Covers reliability and performance of LEDs in harsh environments Has a hands-on applications a...

  12. PETER loop. Multifunctional test facility for thermal hydraulic investigations of PWR fuel elements

    International Nuclear Information System (INIS)

    Ganzmann, I.; Hille, D.; Staude, U.

    2009-01-01

    The reliable fuel element behavior during the complete fuel cycle is one of the fundamental prerequisites of a safe and efficient nuclear power plant operation. The fuel element behavior with respect to pressure drop and vibration impact cannot be simulated by means of fluid-structure interaction codes. Therefore it is necessary to perform tests using fuel element mock-ups (1:1). AREVA NP has constructed the test facility PETER (PWR fuel element tests in Erlangen) loop. The modular construction allows maximum flexibility for any type of fuel elements. Modern measuring instrumentation for flow, pressure and vibration characterization allows the analysis of cause and consequences of thermal hydraulic phenomena. PETER loop is the standard test facility for the qualification of dynamic fuel element behavior in flowing fluid and is used for failure mode analysis.

  13. Reliability Verification of DBE Environment Simulation Test Facility by using Statistics Method

    International Nuclear Information System (INIS)

    Jang, Kyung Nam; Kim, Jong Soeg; Jeong, Sun Chul; Kyung Heum

    2011-01-01

    In the nuclear power plant, all the safety-related equipment including cables under the harsh environment should perform the equipment qualification (EQ) according to the IEEE std 323. There are three types of qualification methods including type testing, operating experience and analysis. In order to environmentally qualify the safety-related equipment using type testing method, not analysis or operation experience method, the representative sample of equipment, including interfaces, should be subjected to a series of tests. Among these tests, Design Basis Events (DBE) environment simulating test is the most important test. DBE simulation test is performed in DBE simulation test chamber according to the postulated DBE conditions including specified high-energy line break (HELB), loss of coolant accident (LOCA), main steam line break (MSLB) and etc, after thermal and radiation aging. Because most DBE conditions have 100% humidity condition, in order to trace temperature and pressure of DBE condition, high temperature steam should be used. During DBE simulation test, if high temperature steam under high pressure inject to the DBE test chamber, the temperature and pressure in test chamber rapidly increase over the target temperature. Therefore, the temperature and pressure in test chamber continue fluctuating during the DBE simulation test to meet target temperature and pressure. We should ensure fairness and accuracy of test result by confirming the performance of DBE environment simulation test facility. In this paper, in order to verify reliability of DBE environment simulation test facility, statistics method is used

  14. Reliability testing of failed fuel location system

    International Nuclear Information System (INIS)

    Vieru, G.

    1996-01-01

    This paper presents the experimental reliability tests performed in order to prove the reliability parameters for Failed Fuel Location System (FFLS), equipment used to detect in which channel of a particular heat transport loop a fuel failure is located, and to find in which channel what particular bundle pair is failed. To do so, D20 samples from each reactor channel are sequentially monitored to detect a comparatively high level of delayed neutron activity. 15 refs, 8 figs, 2 tabs

  15. Column Grid Array Rework for High Reliability

    Science.gov (United States)

    Mehta, Atul C.; Bodie, Charles C.

    2008-01-01

    Due to requirements for reduced size and weight, use of grid array packages in space applications has become common place. To meet the requirement of high reliability and high number of I/Os, ceramic column grid array packages (CCGA) were selected for major electronic components used in next MARS Rover mission (specifically high density Field Programmable Gate Arrays). ABSTRACT The probability of removal and replacement of these devices on the actual flight printed wiring board assemblies is deemed to be very high because of last minute discoveries in final test which will dictate changes in the firmware. The questions and challenges presented to the manufacturing organizations engaged in the production of high reliability electronic assemblies are, Is the reliability of the PWBA adversely affected by rework (removal and replacement) of the CGA package? and How many times can we rework the same board without destroying a pad or degrading the lifetime of the assembly? To answer these questions, the most complex printed wiring board assembly used by the project was chosen to be used as the test vehicle, the PWB was modified to provide a daisy chain pattern, and a number of bare PWB s were acquired to this modified design. Non-functional 624 pin CGA packages with internal daisy chained matching the pattern on the PWB were procured. The combination of the modified PWB and the daisy chained packages enables continuity measurements of every soldered contact during subsequent testing and thermal cycling. Several test vehicles boards were assembled, reworked and then thermal cycled to assess the reliability of the solder joints and board material including pads and traces near the CGA. The details of rework process and results of thermal cycling are presented in this paper.

  16. Thermal testing of solid neutron shielding materials

    International Nuclear Information System (INIS)

    Boonstra, R.H.

    1993-01-01

    In May-June 1989 the first series of full-scale thermal tests was performed on three shielding materials: Bisco Products NS-4-FR, and Reactor Experiments RX-201 and RX-207. The tests are described in Thermal Testing of Solid Neutron Shielding Materials, GA-A19897, R.H. Boonstra, General Atomics (1990), and demonstrated the acceptability of these materials in a thermal accident. Subsequent design changes to the cask rendered these materials unattractive in terms of weight or adequate service temperature margin. For the second test series a material specification was developed for a polypropylene based neutron shield with a softening point of at least 280degF. Table 1 lists the neutron shield materials tested. The Envirotech and Bisco materials are not polypropylene, but were tested as potential backup materials in the event that a satisfactory polypropylene could not be found. The Bisco modified NS-4 and Reactor Experiments HMPP are both acceptable materials from a thermal accident standpoint for use in the shipping cask. Tests of the Kobe PP-R01 and Envirotech HDPE were stopped for safety reasons, due to inability to deal with the heavy smoke, before completion of the 30-minute heating phase. However these materials may prove satisfactory if they could undergo the complete heating. (J.P.N.)

  17. Test facilities for evaluating nuclear thermal propulsion systems

    International Nuclear Information System (INIS)

    Beck, D.F.; Allen, G.C.; Shipers, L.R.; Dobranich, D.; Ottinger, C.A.; Harmon, C.D.; Fan, W.C.; Todosow, M.

    1992-01-01

    Interagency panels evaluating nuclear thermal propulsion (NTP) development options have consistently recognized the need for constructing a major new ground test facility to support fuel element and engine testing. This paper summarizes the requirements, configuration, and baseline performance of some of the major subsystems designed to support a proposed ground test complex for evaluating nuclear thermal propulsion fuel elements and engines being developed for the Space Nuclear Thermal Propulsion (SNTP) program. Some preliminary results of evaluating this facility for use in testing other NTP concepts are also summarized

  18. Thermal testing of solid neutron shielding materials

    International Nuclear Information System (INIS)

    Boonstra, R.H.

    1992-09-01

    Two legal-weight truck casks the GA-4 and GA-9, will carry four PWR and nine BWR spent fuel assemblies, respectively. Each cask has a solid neutron shielding material separating the steel body and the outer steel skin. In the thermal accident specified by NRC regulations in 10CFR Part 71, the cask is subjected to an 800 degree C environment for 30 minutes. The neutron shield need not perform any shielding function during or after the thermal accident, but its behavior must not compromise the ability of the cask to contain the radioactive contents. In May-June 1989 the first series of full-scale thermal tests was performed on three shielding materials: Bisco Products NS-4-FR, and Reactor Experiments RX-201 and RX-207. The tests are described in Thermal Testing of Solid Neutron Shielding Materials, GA-AL 9897, R. H. Boonstra, General Atomics (1990), and demonstrated the acceptability of these materials in a thermal accident. Subsequent design changes to the cask rendered these materials unattractive in terms of weight or adequate service temperature margin. For the second test series, a material specification was developed for a polypropylene based neutron shield with a softening point of at least 280 degree F. The neutron shield materials tested were boronated (0.8--4.5%) polymers (polypropylene, HDPE, NS-4). The Envirotech and Bisco materials are not polypropylene, but were tested as potential backup materials in the event that a satisfactory polypropylene could not be found

  19. Validity, Reliability, and Sensitivity of a Volleyball Intermittent Endurance Test.

    Science.gov (United States)

    Rodríguez-Marroyo, Jose A; Medina-Carrillo, Javier; García-López, Juan; Morante, Juan C; Villa, José G; Foster, Carl

    2017-03-01

    To analyze the concurrent and construct validity of a volleyball intermittent endurance test (VIET). The VIET's test-retest reliability and sensitivity to assess seasonal changes was also studied. During the preseason, 71 volleyball players of different competitive levels took part in this study. All performed the VIET and a graded treadmill test with gas-exchange measurement (GXT). Thirty-one of the players performed an additional VIET to analyze the test-retest reliability. To test the VIET's sensitivity, 28 players repeated the VIET and GXT at the end of their season. Significant (P volleyball players.

  20. Design of Accelerated Reliability Test for CNC Motorized Spindle Based on Vibration Signal

    Directory of Open Access Journals (Sweden)

    Chen Chao

    2016-01-01

    Full Text Available Motorized spindle is the key functional component of CNC machining centers which is a mechatronics system with long life and high reliability. The reliability test cycle of motorized spindle is too long and infeasible. This paper proposes a new accelerated test for reliability evaluation of motorized spindle. By field reliability test, authors collect and calculate the load data including rotational speed, cutting force and torque. Load spectrum distribution law is analyzed. And authors design a test platform to apply the load spectrum. A new method to define the fuzzy acceleration factor based on the vibration signal is proposed. Then the whole test plan of accelerated reliability test is done.

  1. Gearbox Reliability Collaborative Phase 3 Gearbox 2 Test Plan

    Energy Technology Data Exchange (ETDEWEB)

    Link, H.; Keller, J.; Guo, Y.; McNiff, B.

    2013-04-01

    Gearboxes in wind turbines have not been achieving their expected design life even though they commonly meet or exceed the design criteria specified in current design standards. One of the basic premises of the National Renewable Energy Laboratory (NREL) Gearbox Reliability Collaborative (GRC) is that the low gearbox reliability results from the absence of critical elements in the design process or insufficient design tools. Key goals of the GRC are to improve design approaches and analysis tools and to recommend practices and test methods resulting in improved design standards for wind turbine gearboxes that lower the cost of energy (COE) through improved reliability. The GRC uses a combined gearbox testing, modeling and analysis approach, along with a database of information from gearbox failures collected from overhauls and investigation of gearbox condition monitoring techniques to improve wind turbine operations and maintenance practices. Testing of Gearbox 2 (GB2) using the two-speed turbine controller that has been used in prior testing. This test series will investigate non-torque loads, high-speed shaft misalignment, and reproduction of field conditions in the dynamometer. This test series will also include vibration testing using an eddy-current brake on the gearbox's high speed shaft.

  2. Proportional and Integral Thermal Control System for Large Scale Heating Tests

    Science.gov (United States)

    Fleischer, Van Tran

    2015-01-01

    The National Aeronautics and Space Administration Armstrong Flight Research Center (Edwards, California) Flight Loads Laboratory is a unique national laboratory that supports thermal, mechanical, thermal/mechanical, and structural dynamics research and testing. A Proportional Integral thermal control system was designed and implemented to support thermal tests. A thermal control algorithm supporting a quartz lamp heater was developed based on the Proportional Integral control concept and a linearized heating process. The thermal control equations were derived and expressed in terms of power levels, integral gain, proportional gain, and differences between thermal setpoints and skin temperatures. Besides the derived equations, user's predefined thermal test information generated in the form of thermal maps was used to implement the thermal control system capabilities. Graphite heater closed-loop thermal control and graphite heater open-loop power level were added later to fulfill the demand for higher temperature tests. Verification and validation tests were performed to ensure that the thermal control system requirements were achieved. This thermal control system has successfully supported many milestone thermal and thermal/mechanical tests for almost a decade with temperatures ranging from 50 F to 3000 F and temperature rise rates from -10 F/s to 70 F/s for a variety of test articles having unique thermal profiles and test setups.

  3. Validity and Reliability of a Medicine Ball Explosive Power Test.

    Science.gov (United States)

    Stockbrugger, Barry A.; Haennel, Robert G.

    2001-01-01

    Evaluated the validity and reliability of a medicine ball throw test to evaluate explosive power. Data on competitive sand volleyball players who performed a medicine ball throw and a standard countermovement jump indicated that the medicine ball throw test was a valid and reliable way to assess explosive power for an analogous total-body movement…

  4. An Integrated Approach to Establish Validity and Reliability of Reading Tests

    Science.gov (United States)

    Razi, Salim

    2012-01-01

    This study presents the processes of developing and establishing reliability and validity of a reading test by administering an integrative approach as conventional reliability and validity measures superficially reveals the difficulty of a reading test. In this respect, analysing vocabulary frequency of the test is regarded as a more eligible way…

  5. Determining the thermal expansion coefficient of thin films for a CMOS MEMS process using test cantilevers

    International Nuclear Information System (INIS)

    Cheng, Chao-Lin; Fang, Weileun; Tsai, Ming-Han

    2015-01-01

    Many standard CMOS processes, provided by existing foundries, are available. These standard CMOS processes, with stacking of various metal and dielectric layers, have been extensively applied in integrated circuits as well as micro-electromechanical systems (MEMS). It is of importance to determine the material properties of the metal and dielectric films to predict the performance and reliability of micro devices. This study employs an existing approach to determine the coefficients of thermal expansion (CTEs) of metal and dielectric films for standard CMOS processes. Test cantilevers with different stacking of metal and dielectric layers for standard CMOS processes have been designed and implemented. The CTEs of standard CMOS films can be determined from measurements of the out-of-plane thermal deformations of the test cantilevers. To demonstrate the feasibility of the present approach, thin films prepared by the Taiwan Semiconductor Manufacture Company 0.35 μm 2P4M CMOS process are characterized. Eight test cantilevers with different stacking of CMOS layers and an auxiliary Si cantilever on a SOI wafer are fabricated. The equivalent elastic moduli and CTEs of the CMOS thin films including the metal and dielectric layers are determined, respectively, from the resonant frequency and static thermal deformation of the test cantilevers. Moreover, thermal deformations of cantilevers with stacked layers different to those of the test beams have been employed to verify the measured CTEs and elastic moduli. (paper)

  6. The test-retest reliability and criterion validity of a high-intensity, netball-specific circuit test: The Net-Test.

    Science.gov (United States)

    Mungovan, Sean F; Peralta, Paula J; Gass, Gregory C; Scanlan, Aaron T

    2018-04-12

    To examine the test-retest reliability and criterion validity of a high-intensity, netball-specific fitness test. Repeated measures, within-subject design. Eighteen female netball players competing in an international competition completed a trial of the Net-Test, which consists of 14 timed netball-specific movements. Players also completed a series of netball-relevant criterion fitness tests. Ten players completed an additional Net-Test trial one week later to assess test-retest reliability using intraclass correlation coefficient (ICC), typical error of measurement (TEM), and coefficient of variation (CV). The typical error of estimate expressed as CV and Pearson correlations were calculated between each criterion test and Net-Test performance to assess criterion validity. Five movements during the Net-Test displayed moderate ICC (0.84-0.90) and two movements displayed high ICC (0.91-0.93). Seven movements and heart rate taken during the Net-Test held low CV (Test possessed low CV and significant (pTest possesses acceptable reliability for the assessment of netball fitness. Further, the high criterion validity for the Net-Test suggests a range of important netball-specific fitness elements are assessed in combination. Copyright © 2018 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  7. Reliability Testing of Cable on Environmental Humidity Condition

    International Nuclear Information System (INIS)

    Situmorang, Johnny; Puradwi, I.W; Sony T, D.T; Handoyo, Demon; Mulyanto, Dwijo; Kusmono, Slamet

    2000-01-01

    Reliability testing of cable on humidified condition has been carried out. As a result, the failure occurred due to reduction of current by increasing the resistance on rising temperature testing. For humidified condition the result which are observed did not significant at the stated condition of testing. The needed time up to the failure criteria increased as a temperature testing increased

  8. Temperatures, strains and crack behavior during local thermal shock tests on the RPV-cylinder of the HDR

    International Nuclear Information System (INIS)

    Neubrech, G.E.; Goerner, F.; Siebler, T.

    1987-01-01

    This report summarises and critically discusses the results obtained from thermal shocks locally applied to the inner surface of the RPV-cylinder. This evaluation is based on on-line measurements (temperatures and strains at the RPV-wall during the thermal shock loading, non-destructive-testing), on materials investigations, and on theoretical investigations (finite element calculations, fracture mechanics analyses). The comparison between the corresponding measured and calculated results serves as a basis for subsequent assessments. It was the object of these tests to achieve the following primary aims: - Investigation of the loading conditions produced by local thermal shocks during realistic cooling processes. - A better understanding of the physical processes involved in crack initiation and propagation resulting from thermocyclic loading. - Assessment of non-destructive-testing methods with respect to detection and analysis of cracks as a basis for fracture mechanical evaluations. - Assessment of the reliability of the applied structural analysis methods. - Production of naturally formed deep cracks on the inner surface of the RPV-cylinder by means of excessive cooling processes. (orig./HP)

  9. Reasoning with Inductive Argument Test: A Study of Validity and Reliability

    Directory of Open Access Journals (Sweden)

    Mehmet Emrah Karadere

    2013-11-01

    Full Text Available Reasoning with Inductive Argument Test:A Study of Validity and Reliability Objective: The aim of our study is to research reliability and validity and to evaluate the usability of Turkish version of Reasoning with Inductive Argument Test (RIAT in Turkish healty population. Method: 51 healty volunteers who work in Ankara Dıskapi Yildirim Beyazit Research and Training Hospital participated in this study. Reasoning with Inductive Argument Test (RIAT was translated into Turkish by three clinical good knowledge of English. Participants were given a sociodemographic data form, and RIAT were performed by clinicians. To test the reliability of the Turkish version of RIAT, Cronbach’s alpha coefficient was calculated and the halving method was used for the test. Results: The internal consistency of the Reasoning with Inductive Argument Test (RIAT items, Cronbach’s alpha internal consistency coefficient measurements of 0.73 was found to be statistically significant. Spearman-Brown coefficient that determines the reliability of the whole test r=0.74 was found. Kurtosis values of all the items was below 1.5 and the percentages in the second evaluation were mainly lower. At the same time, both change in belief between self produced RIAT options and given RIAT options (p=0.02, z=-2296 as well as changes in beliefs between related and unrelated items for Obsessive Compulsive Disorder (OCD difference (p=0.03, z=-2.199 were significant. Conclusion: The preliminary data obtained from the study of reliability and validity of the scale shows that ‘Reasoning with Inductive Argument Test’ supports reliability and validity in Turkish population.

  10. Thermal testing of solid neutron shielding materials

    International Nuclear Information System (INIS)

    Boonstra, R.H.

    1990-03-01

    The GA-4 and GA-9 spent fuel shipping casks employ a solid neutron shielding material. During a hypothetical thermal accident, any combustion of the neutron shield must not compromise the ability of the cask to contain the radioactive contents. A two-phase thermal testing program was carried out to assist in selecting satisfactory shielding materials. In the first phase, small-scale screening tests were performed on nine candidate materials using ASTM procedures. From these initial results, three of the nine candidates were chosen for inclusion in the second phase of testing, These materials were Bisco Products NS-4-FR, Reactor Experiments 201-1, and Reactor Experiments 207. In the second phase, each selected material was fabricated into a test article which simulated a full-scale of neutron shield from the cask. The test article was heated in an environmental prescribed by NRC regulations. Results of this second testing phase showed that all three materials are thermally acceptable

  11. Thermal testing of solid neutron shielding materials

    International Nuclear Information System (INIS)

    Boonstra, R.N.

    1990-01-01

    The GA-4 and GA-9 spent fuel shipping casks employ a solid neutron shielding material. During a hypothetical thermal accident, any combustion of the neutron shield must not compromise the ability of the cask to contain the radioactive contents. A two-phase thermal testing program was carried out to assist in selecting satisfactory shielding materials. In the first phase, small-scale screening tests were performed on nine candidate materials using ASTM procedures. From these initial results, three of the nine candidates were chosen for inclusion in the second phase of testing. These materials were Bisco Products NS-4-FR, Reactor Experiments 201-1, and Reactor Experiments 207. In the second phase, each selected material was fabricated into a test article which simulated a full-scale section of neutron shield from the cask. The test article was heated in an environment prescribed by NRC regulations. Results of this second testing phase show that all three materials are thermally acceptable

  12. Educational testing validity and reliability in pharmacy and medical education literature.

    Science.gov (United States)

    Hoover, Matthew J; Jung, Rose; Jacobs, David M; Peeters, Michael J

    2013-12-16

    To evaluate and compare the reliability and validity of educational testing reported in pharmacy education journals to medical education literature. Descriptions of validity evidence sources (content, construct, criterion, and reliability) were extracted from articles that reported educational testing of learners' knowledge, skills, and/or abilities. Using educational testing, the findings of 108 pharmacy education articles were compared to the findings of 198 medical education articles. For pharmacy educational testing, 14 articles (13%) reported more than 1 validity evidence source while 83 articles (77%) reported 1 validity evidence source and 11 articles (10%) did not have evidence. Among validity evidence sources, content validity was reported most frequently. Compared with pharmacy education literature, more medical education articles reported both validity and reliability (59%; particles in pharmacy education compared to medical education, validity, and reliability reporting were limited in the pharmacy education literature.

  13. Construction and Evaluation of Reliability and Validity of Reasoning Ability Test

    Science.gov (United States)

    Bhat, Mehraj A.

    2014-01-01

    This paper is based on the construction and evaluation of reliability and validity of reasoning ability test at secondary school students. In this paper an attempt was made to evaluate validity, reliability and to determine the appropriate standards to interpret the results of reasoning ability test. The test includes 45 items to measure six types…

  14. Development of an accelerated reliability test schedule for terrestrial solar cells

    Science.gov (United States)

    Lathrop, J. W.; Prince, J. L.

    1981-01-01

    An accelerated test schedule using a minimum amount of tests and a minimum number of cells has been developed on the basis of stress test results obtained from more than 1500 cells of seven different cell types. The proposed tests, which include bias-temperature, bias-temperature-humidity, power cycle, thermal cycle, and thermal shock tests, use as little as 10 and up to 25 cells, depending on the test type.

  15. Numerical thermal mathematical model correlation to thermal balance test using adaptive particle swarm optimization (APSO)

    International Nuclear Information System (INIS)

    Beck, T.; Bieler, A.; Thomas, N.

    2012-01-01

    We present structural and thermal model (STM) tests of the BepiColombo laser altimeter (BELA) receiver baffle with emphasis on the correlation of the data with a thermal mathematical model. The test unit is a part of the thermal and optical protection of the BELA instrument being tested under infrared and solar irradiation at University of Bern. An iterative optimization method known as particle swarm optimization has been adapted to adjust the model parameters, mainly the linear conductivity, in such a way that model and test results match. The thermal model reproduces the thermal tests to an accuracy of 4.2 °C ± 3.2 °C in a temperature range of 200 °C after using only 600 iteration steps of the correlation algorithm. The use of this method brings major benefits to the accuracy of the results as well as to the computational time required for the correlation. - Highlights: ► We present model correlations of the BELA receiver baffle to thermal balance tests. ► Adaptive particle swarm optimization has been adapted for the correlation. ► The method improves the accuracy of the correlation and the computational time.

  16. Survey of solar thermal test facilities

    Energy Technology Data Exchange (ETDEWEB)

    Masterson, K.

    1979-08-01

    The facilities that are presently available for testing solar thermal energy collection and conversion systems are briefly described. Facilities that are known to meet ASHRAE standard 93-77 for testing flat-plate collectors are listed. The DOE programs and test needs for distributed concentrating collectors are identified. Existing and planned facilities that meet these needs are described and continued support for most of them is recommended. The needs and facilities that are suitable for testing components of central receiver systems, several of which are located overseas, are identified. The central contact point for obtaining additional details and test procedures for these facilities is the Solar Thermal Test Facilities Users' Association in Albuquerque, N.M. The appendices contain data sheets and tables which give additional details on the technical capabilities of each facility. Also included is the 1975 Aerospace Corporation report on test facilities that is frequently referenced in the present work.

  17. IRT-Estimated Reliability for Tests Containing Mixed Item Formats

    Science.gov (United States)

    Shu, Lianghua; Schwarz, Richard D.

    2014-01-01

    As a global measure of precision, item response theory (IRT) estimated reliability is derived for four coefficients (Cronbach's a, Feldt-Raju, stratified a, and marginal reliability). Models with different underlying assumptions concerning test-part similarity are discussed. A detailed computational example is presented for the targeted…

  18. Evaluating the reliability of an injury prevention screening tool: Test-retest study.

    Science.gov (United States)

    Gittelman, Michael A; Kincaid, Madeline; Denny, Sarah; Wervey Arnold, Melissa; FitzGerald, Michael; Carle, Adam C; Mara, Constance A

    2016-10-01

    A standardized injury prevention (IP) screening tool can identify family risks and allow pediatricians to address behaviors. To assess behavior changes on later screens, the tool must be reliable for an individual and ideally between household members. Little research has examined the reliability of safety screening tool questions. This study utilized test-retest reliability of parent responses on an existing IP questionnaire and also compared responses between household parents. Investigators recruited parents of children 0 to 1 year of age during admission to a tertiary care children's hospital. When both parents were present, one was chosen as the "primary" respondent. Primary respondents completed the 30-question IP screening tool after consent, and they were re-screened approximately 4 hours later to test individual reliability. The "second" parent, when present, only completed the tool once. All participants received a 10-dollar gift card. Cohen's Kappa was used to estimate test-retest reliability and inter-rater agreement. Standard test-retest criteria consider Kappa values: 0.0 to 0.40 poor to fair, 0.41 to 0.60 moderate, 0.61 to 0.80 substantial, and 0.81 to 1.00 as almost perfect reliability. One hundred five families participated, with five lost to follow-up. Thirty-two (30.5%) parent dyads completed the tool. Primary respondents were generally mothers (88%) and Caucasian (72%). Test-retest of the primary respondents showed their responses to be almost perfect; average 0.82 (SD = 0.13, range 0.49-1.00). Seventeen questions had almost perfect test-retest reliability and 11 had substantial reliability. However, inter-rater agreement between household members for 12 objective questions showed little agreement between responses; inter-rater agreement averaged 0.35 (SD = 0.34, range -0.19-1.00). One question had almost perfect inter-rater agreement and two had substantial inter-rater agreement. The IP screening tool used by a single individual had excellent

  19. JENDL-3.3 thermal reactor benchmark test

    International Nuclear Information System (INIS)

    Akie, Hiroshi

    2001-01-01

    Integral tests of JENDL-3.2 nuclear data library have been carried out by Reactor Integral Test WG of Japanese Nuclear Data Committee. The most important problem in the thermal reactor benchmark testing was the overestimation of the multiplication factor of the U fueled cores. With several revisions of the data of 235 U and the other nuclides, JENDL-3.3 data library gives a good estimation of multiplication factors both for U and Pu fueled thermal reactors. (author)

  20. Balance Assessment in Sports-Related Concussion: Evaluating Test-Retest Reliability of the Equilibrate System.

    Science.gov (United States)

    Odom, Mitchell J; Lee, Young M; Zuckerman, Scott L; Apple, Rachel P; Germanos, Theodore; Solomon, Gary S; Sills, Allen K

    2016-01-01

    This study evaluated the test-retest reliability of a novel computer-based, portable balance assessment tool, the Equilibrate System (ES), used to diagnose sports-related concussion. Twenty-seven students participated in ES testing consisting of three sessions over 4 weeks. The modified Balance Error Scoring System was performed. For each participant, test-retest reliability was established using the intraclass correlation coefficient (ICC). The ES test-retest reliability from baseline to week 2 produced an ICC value of 0.495 (95% CI, 0.123-0.745). Week 2 testing produced ICC values of 0.602 (95% CI, 0.279-0.803) and 0.610 (95% CI, 0.299-0.804), respectively. All other single measures test-retest reliability values produced poor ICC values. Same-day ES testing showed fair to good test-retest reliability while interweek measures displayed poor to fair test-retest reliability. Testing conditions should be controlled when using computerized balance assessment methods. ES testing should only be used as a part of a comprehensive assessment.

  1. CRYogenic Orbital TEstbed Ground Test Article Thermal Analysis

    Science.gov (United States)

    Piryk, David; Schallhorn, Paul; Walls, Laurie; Stopnitzky, Benny; Rhys, Noah; Wollen, Mark

    2012-01-01

    The purpose of this study was to anchor thermal and fluid system models to CRYOTE ground test data. The CRYOTE ground test artide was jointly developed by Innovative Engineering Solutions, United Launch Alliance and NASA KSC. The test article was constructed out of a titanium alloy tank, Sapphire 77 composite skin (similar to G10), an external secondary payload adapter ring, thermal vent system, multi layer insulation and various data acquisition instrumentation. In efforts to understand heat loads throughout this system, the GTA (filled with liquid nitrogen for safety purposes) was subjected to a series of tests in a vacuum chamber at Marshall Space Flight Center. By anchoring analytical models against test data, higher fidelity thermal environment predictions can be made for future flight articles which would eventually demonstrate critical cryogenic fluid management technologies such as system chilldown, transfer, pressure control and long term storage. Significant factors that influenced heat loads included radiative environments, multi-layer insulation performance, tank fill levels and pressures and even contact conductance coefficients. This report demonstrates how analytical thermal/fluid networks were established and includes supporting rationale for specific thermal responses.

  2. Test of understanding of vectors: A reliable multiple-choice vector concept test

    Science.gov (United States)

    Barniol, Pablo; Zavala, Genaro

    2014-06-01

    In this article we discuss the findings of our research on students' understanding of vector concepts in problems without physical context. First, we develop a complete taxonomy of the most frequent errors made by university students when learning vector concepts. This study is based on the results of several test administrations of open-ended problems in which a total of 2067 students participated. Using this taxonomy, we then designed a 20-item multiple-choice test [Test of understanding of vectors (TUV)] and administered it in English to 423 students who were completing the required sequence of introductory physics courses at a large private Mexican university. We evaluated the test's content validity, reliability, and discriminatory power. The results indicate that the TUV is a reliable assessment tool. We also conducted a detailed analysis of the students' understanding of the vector concepts evaluated in the test. The TUV is included in the Supplemental Material as a resource for other researchers studying vector learning, as well as instructors teaching the material.

  3. Outdoor test method to determine the thermal behavior of solar domestic water heating systems

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Valladares, O.; Pilatowsky, I. [Centro de Investigacion en Energia, Universidad Nacional Autonoma de Mexico, Privada Xochicalco, s/n, Colonia Centro, 62580 Temixco, Morelos (Mexico); Ruiz, V. [Escuela Tecnica Superior de Ingenieros, Universidad de Sevilla, Camino de los Descubrimientos, s/n, Isla de la Cartuja, 41092 Sevilla, Espana (Spain)

    2008-07-15

    The dynamics of the market, the generation of new promotion programs, fiscal incentives and many other factors are to be considered for the massive application of solar domestic water heating systems (SDWHS) mainly of the compact thermosiphon type, makes it necessary to choose simple and inexpensive procedure tests that permit to know their characteristic thermal behaviors without an official standard being necessary. Moreover, it allows the comparison among systems and offers enough and reliable information to consumers and manufacturers. In most developing countries, an official national standard for SDWHS is not available, therefore it is necessary to adopt an international test procedure in which the cost and time of implementation is very important. In this work, a simple and inexpensive test method to determine the thermal behavior of SDWHS is proposed. Even though these procedure tests do not have an official standard structure they permit, by comparing different solar systems under identical solar, ambient, and initial conditions, the experimental determination of: (a) the maximum available volume of water for solar heating; (b) water temperature increment and available thermal energy at the end of the day; (c) temperature profiles (stratification) and the average temperature in the storage tank after it is homogenized; (d) the average global thermal efficiency; (e) water temperature decrement and energy lost overnight; and (f) the relationship between hot water volume and solar collector area as function of the average heating temperature. An additional proposed test permits to know the heat losses caused by the reverse flow in the collector loop. These tests will be carried out independently of the configuration between the solar collector and the storage tank, the way the fluid circulates and the type of thermal exchange. The results of this procedure test can be very useful, firstly, for the local solar manufacturers' equipment in order to design

  4. Outdoor test method to determine the thermal behavior of solar domestic water heating systems

    International Nuclear Information System (INIS)

    Garcia-Valladares, O.; Pilatowsky, I.; Ruiz, V.

    2008-01-01

    The dynamics of the market, the generation of new promotion programs, fiscal incentives and many other factors are to be considered for the massive application of solar domestic water heating systems (SDWHS) mainly of the compact thermosiphon type, makes it necessary to choose simple and inexpensive procedure tests that permit to know their characteristic thermal behaviors without an official standard being necessary. Moreover, it allows the comparison among systems and offers enough and reliable information to consumers and manufacturers. In most developing countries, an official national standard for SDWHS is not available, therefore it is necessary to adopt an international test procedure in which the cost and time of implementation is very important. In this work, a simple and inexpensive test method to determine the thermal behavior of SDWHS is proposed. Even though these procedure tests do not have an official standard structure they permit, by comparing different solar systems under identical solar, ambient, and initial conditions, the experimental determination of: (a) the maximum available volume of water for solar heating; (b) water temperature increment and available thermal energy at the end of the day; (c) temperature profiles (stratification) and the average temperature in the storage tank after it is homogenized; (d) the average global thermal efficiency; (e) water temperature decrement and energy lost overnight; and (f) the relationship between hot water volume and solar collector area as function of the average heating temperature. An additional proposed test permits to know the heat losses caused by the reverse flow in the collector loop. These tests will be carried out independently of the configuration between the solar collector and the storage tank, the way the fluid circulates and the type of thermal exchange. The results of this procedure test can be very useful, firstly, for the local solar manufacturers' equipment in order to design and

  5. Reliability demonstration methodology for products with Gamma Process by optimal accelerated degradation testing

    International Nuclear Information System (INIS)

    Zhang, Chunhua; Lu, Xiang; Tan, Yuanyuan; Wang, Yashun

    2015-01-01

    For products with high reliability and long lifetime, accelerated degradation testing (ADT) may be adopted during product development phase to verify whether its reliability satisfies the predetermined level within feasible test duration. The actual degradation from engineering is usually a strictly monotonic process, such as fatigue crack growth, wear, and erosion. However, the method for reliability demonstration by ADT with monotonic degradation process has not been investigated so far. This paper proposes a reliability demonstration methodology by ADT for this kind of product. We first apply Gamma process to describe the monotonic degradation. Next, we present a reliability demonstration method by converting the required reliability level into allowable cumulative degradation in ADT and comparing the actual accumulative degradation with the allowable level. Further, we suggest an analytical optimal ADT design method for more efficient reliability demonstration by minimizing the asymptotic variance of decision variable in reliability demonstration under the constraints of sample size, test duration, test cost, and predetermined decision risks. The method is validated and illustrated with example on reliability demonstration of alloy product, and is applied to demonstrate the wear reliability within long service duration of spherical plain bearing in the end. - Highlights: • We present a reliability demonstration method by ADT for products with monotonic degradation process, which may be applied to verify reliability with long service life for products with monotonic degradation process within feasible test duration. • We suggest an analytical optimal ADT design method for more efficient reliability demonstration, which differs from the existed optimal ADT design for more accurate reliability estimation by different objective function and different constraints. • The methods are applied to demonstrate the wear reliability within long service duration of

  6. 40 CFR 91.329 - Catalyst thermal stress test.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Catalyst thermal stress test. 91.329....329 Catalyst thermal stress test. (a) Oven characteristics. The oven used for termally stressing the test catalyst must be capable of maintaining a temperature of 500 ±5 °C and 1000 ±10 °C. (b) Evaluation...

  7. A Latent Class Approach to Estimating Test-Score Reliability

    Science.gov (United States)

    van der Ark, L. Andries; van der Palm, Daniel W.; Sijtsma, Klaas

    2011-01-01

    This study presents a general framework for single-administration reliability methods, such as Cronbach's alpha, Guttman's lambda-2, and method MS. This general framework was used to derive a new approach to estimating test-score reliability by means of the unrestricted latent class model. This new approach is the latent class reliability…

  8. Validity and reliability of tests determining performance-related components of wheelchair basketball

    NARCIS (Netherlands)

    De Groot, Sonja; Balvers, Inge J. M.; Kouwenhoven, Sanne M.; Janssen, Thomas W. J.

    2012-01-01

    The purpose of this study was to investigate the reliability and validity of wheelchair basketball field tests. Nineteen wheelchair basketball players performed 10 test items twice to determine the reliability. The validity of the tests was assessed by relating the scores to the players'

  9. Validity and reliability of tests determining performance-related components of wheelchair basketball

    NARCIS (Netherlands)

    de Groot, Sonja; Balvers, Inge J.M.; Kouwenhoven, Sanne M.; Janssen, Thomas W.J.

    The purpose of this study was to investigate the reliability and validity of wheelchair basketball field tests. Nineteen wheelchair basketball players performed 10 test items twice to determine the reliability. The validity of the tests was assessed by relating the scores to the players'

  10. Strength and Pain Threshold Handheld Dynamometry Test Reliability in Patellofemoral Pain.

    Science.gov (United States)

    van der Heijden, R A; Vollebregt, T; Bierma-Zeinstra, S M A; van Middelkoop, M

    2015-12-01

    Patellofemoral pain syndrome (PFPS), characterized by peri- and retropatellar pain, is a common disorder in young, active people. The etiology is unclear; however, quadriceps strength seems to be a contributing factor, and sensitization might play a role. The study purpose is determining the inter-rater reliability of handheld dynamometry to test both quadriceps strength and pressure pain threshold (PPT), a measure for sensitization, in patients with PFPS. This cross-sectional case-control study comprises 3 quadriceps strength and one PPT measurements performed by 2 independent investigators in 22 PFPS patients and 16 matched controls. Inter-rater reliability was analyzed using intraclass correlation coefficients (ICC) and Bland-Altman plots. Inter-rater reliability of quadriceps strength testing was fair to good in PFPS patients (ICC=0.72) and controls (ICC=0.63). Bland-Altman plots showed an increased difference between assessors when average quadriceps strength values exceeded 250 N. Inter-rater reliability of PPT was excellent in patients (ICC=0.79) and fair to good in controls (ICC=0.52). Handheld dynamometry seems to be a reliable method to test both quadriceps strength and PPT in PFPS patients. Inter-rater reliability was higher in PFPS patients compared to control subjects. With regard to quadriceps testing, a higher variance between assessors occurs when quadriceps strength increases. © Georg Thieme Verlag KG Stuttgart · New York.

  11. Enhance pump reliability through improved inservice testing

    International Nuclear Information System (INIS)

    Healy, J.J.

    1990-01-01

    EPRI has undertaken a study to assess the effectiveness of existing testing programs to accurately monitor and predict performance changes before either pump performance degrades or an actual failure occurs. Anticipated changes in inservice testing techniques are directed towards enhancing the validity of test data, ensuring its repeatability, and avoiding deterioration of the pump assembly. There is a new-found interest in test programs of all types that has occurred, in part, because of an increase in reported pump degradation and pump failure. Inservice testing of pumps, which has long been a basis for assuring operability, has apparently produced an opposite effect; namely, the appearance of a reduction in reliability

  12. Test-retest reliability of the Military Pre-training Questionnaire.

    Science.gov (United States)

    Robinson, M; Stokes, K; Bilzon, J; Standage, M; Brown, P; Thompson, D

    2010-09-01

    Musculoskeletal injuries are a significant cause of morbidity during military training. A brief, inexpensive and user-friendly tool that demonstrates reliability and validity is warranted to effectively monitor the relationship between multiple predictor variables and injury incidence in military populations. To examine the test-retest reliability of the Military Pre-training Questionnaire (MPQ), designed specifically to assess risk factors for injury among military trainees across five domains (physical activity, injury history, diet, alcohol and smoking). Analyses were based on a convenience sample of 58 male British Army trainees. Kappa (kappa), weighted kappa (kappa(w)) and intraclass correlation coefficients (ICC) were used to evaluate the 2-week test-retest reliability of the MPQ. For index measures constituting the assessment of a given construct, internal consistency was assessed by Cronbach's alpha (alpha) coefficients. Reliability of individual items ranged from poor to almost perfect (kappa range = 0.45-0.86; kappa(w) range = 0.11-0.91; ICC range = 0.34-0.86) with most items demonstrating moderate reliability. Overall scores related to physical activity, diet, alcohol and smoking constructs were reliable between both administrations (ICC = 0.63-0.85). Support for the internal consistency of the incorporated alcohol (alpha = 0.78) and cigarette (alpha = 0.75) scales was also provided. The MPQ is a reliable self-report instrument for assessing multiple injury-related risk factors during initial military training. Further assessment of the psychometric properties of the MPQ (e.g. different types of validity) with military populations/samples will support its interpretation and use in future surveillance and epidemiological studies.

  13. Assessing Reliability of Two Versions of Vocabulary Levels Tests in Iranian Context

    Directory of Open Access Journals (Sweden)

    Aso Bayazidi

    2017-02-01

    Full Text Available This study examined the equivalence and reliability of the two versions of the Vocabulary Levels Test in an Iranian context. This study was motivated by the fact that the Vocabulary Levels test is increasingly being used in Iran for both research and pedagogical purposes without having been checked for validity and reliability in this context. The equivalence and reliability of the two versions of the test were examined through the parallel-form approach to reliability in Classical True Score theory. Seventy-five intermediate learners of English as a foreign language at the Iran Language Institute took the two versions of the test with one week interval between the two administrations in a counterbalanced fashion. To examine the equivalence of the two versions, the means and variances of the scores obtained for the two tests were compared using paired-sample t-test and one-way ANOVA, respectively. The results of the analyses indicated that the difference between the means of the two versions was significant, and the two versions cannot be considered as parallel forms. To assess the reliability of the two versions, the correlation between the scores obtained from them was estimated using Pearson Product Moment correlation. The results of the analyses showed that the two versions are highly correlated and are reliable tests. It is concluded that the two versions should not be treated as equivalent in longitudinal and gain score studies.

  14. Reliability and accuracy of Cooper's test in male long distance runners

    OpenAIRE

    J.R. Alvero-Cruz; M.A. Giráldez García; E.A. Carnero

    2017-01-01

    Objective: Endurance capacity can be assessed by field test such as Cooper's test; however, reliability and accuracy are rarely reported in the literature. It was our aims to describe reliability and accuracy of Cooper's test in long distance runners. Method: Fifteen male long distance runners performed twice all-out Cooper's test in a 400 m track. Total distance covered, maximum heart rate (HR) and rate of perceived exertion were recorded. Bias correction factor (Bc) was used to describe ...

  15. Reliability of four experimental mechanical pain tests in children

    DEFF Research Database (Denmark)

    Søe, Ann-Britt Langager; Thomsen, Lise L; Tornoe, Birte

    2013-01-01

    In order to study pain in children, it is necessary to determine whether pain measurement tools used in adults are reliable measurements in children. The aim of this study was to explore the intrasession reliability of pressure pain thresholds (PPT) in healthy children. Furthermore, the aim was a...... was also to study the intersession reliability of the following four tests: (1) Total Tenderness Score; (2) PPT; (3) Visual Analog Scale score at suprapressure pain threshold; and (4) area under the curve (stimulus-response functions for pressure versus pain).......In order to study pain in children, it is necessary to determine whether pain measurement tools used in adults are reliable measurements in children. The aim of this study was to explore the intrasession reliability of pressure pain thresholds (PPT) in healthy children. Furthermore, the aim...

  16. Comparison of the reliability of parental reporting and the direct test of the Thai Speech and Language Test.

    Science.gov (United States)

    Prathanee, Benjamas; Angsupakorn, Nipa; Pumnum, Tawitree; Seepuaham, Cholada; Jaiyong, Pechcharat

    2012-11-01

    To find reliability of parental or caregiver's report and testing of the Thai Speech and Language Test for Children Aged 0-4 Years Old. Five investigators assessed speech and language abilities from video both contexts: parental or caregivers' report and test forms of Thai Speech and Language Test for Children Aged 0-4 Years Old. Twenty-five normal and 30 children with delayed development or risk for delayed speech and language skills were assessed at age intervals of 3, 6, 9, 12, 15, 18, 24, 30, 36 and 48 months. Reliability of parental or caregivers' testing and reporting was at a moderate level (0.41-0.60). Inter-rater reliability among investigators was excellent (0.86-1.00). The parental or caregivers' report form of the Thai Speech and Language test for Children aged 0-4 years old was an indicator for success at a moderate level. Trained professionals could use both forms of this test as reliable tools at an excellent level.

  17. Flexible thermal cycle test equipment for concentrator solar cells

    Science.gov (United States)

    Hebert, Peter H [Glendale, CA; Brandt, Randolph J [Palmdale, CA

    2012-06-19

    A system and method for performing thermal stress testing of photovoltaic solar cells is presented. The system and method allows rapid testing of photovoltaic solar cells under controllable thermal conditions. The system and method presents a means of rapidly applying thermal stresses to one or more photovoltaic solar cells in a consistent and repeatable manner.

  18. Thermal Conductivity Analysis and Lifetime Testing of Suspension Plasma-Sprayed Thermal Barrier Coatings

    Directory of Open Access Journals (Sweden)

    Nicholas Curry

    2014-08-01

    Full Text Available Suspension plasma spraying (SPS has become an interesting method for the production of thermal barrier coatings for gas turbine components. The development of the SPS process has led to structures with segmented vertical cracks or column-like structures that can imitate strain-tolerant air plasma spraying (APS or electron beam physical vapor deposition (EB-PVD coatings. Additionally, SPS coatings can have lower thermal conductivity than EB-PVD coatings, while also being easier to produce. The combination of similar or improved properties with a potential for lower production costs makes SPS of great interest to the gas turbine industry. This study compares a number of SPS thermal barrier coatings (TBCs with vertical cracks or column-like structures with the reference of segmented APS coatings. The primary focus has been on lifetime testing of these new coating systems. Samples were tested in thermo-cyclic fatigue at temperatures of 1100 °C for 1 h cycles. Additional testing was performed to assess thermal shock performance and erosion resistance. Thermal conductivity was also assessed for samples in their as-sprayed state, and the microstructures were investigated using SEM.

  19. Gearbox Reliability Collaborative Phase 3 Gearbox 2 Test Report

    Energy Technology Data Exchange (ETDEWEB)

    Keller, Jonathan; Wallen, Robb

    2015-06-10

    Many gearboxes in wind turbines have not been achieving their expected design life [1]; they do, however, commonly meet or exceed the design criteria specified in current standards in the gear, bearing, and wind turbine industry as well as third-party certification criteria. The cost of gearbox replacements and rebuilds, as well as the downtime associated with these failures, has elevated the cost of wind energy. In 2006, the U.S. Department of Energy established the National Renewable Energy Laboratory (NREL) Gearbox Reliability Collaborative (GRC). Its key goal is to understand the root causes of premature gearbox failures and improve their reliability [2]. The GRC is examining a hypothesis that the gap between design-estimated and actual wind turbine gearbox reliability is caused by underestimation of loads, inaccurate design tools, the absence of critical elements in the design process, or insufficient testing. This test report describes the recent tests of GRC gearbox (GB) 2 in the National Wind Technology Center (NWTC) dynamometer and documents any modifications to the original test plan [3]. In this manner, it serves as a guide for interpreting the publicly released data sets with brief analyses to illustrate the data. Specific objectives of the test were to assess the effect of dynamic nontorque load (NTL) on the planetary section, generator misalignment on the highspeed shaft (HSS), and field representative conditions on the gearbox in general. Detailed analysis of those test objectives will be presented in subsequent publications.

  20. Reliable and sensitive physical testing of elite trapeze sailors

    DEFF Research Database (Denmark)

    Bay, Jonathan; Bojsen-Møller, Jens; Nordsborg, Nikolai Baastrup

    2018-01-01

    It was investigated, if a newly developed discipline specific test for elite-level trapeze sailors is reli-able and sensitive. Furthermore, the physical demands of trapeze sailing were examined. In part 1, nine national team athletes were accustomed to a simulated sailing test, which subsequently....... 265 ± 45W, Psailing was 54.5 ± 7.2% VO2max , 75.1 ± 3.1% HRmax and 5.8 ± 2.7 mM, respectively. However, VO2 and HR were substantially higher for periods of the race...... as peak values were 83.5 ± 11.4% and 89.9 ± 1.7% of max, respectively. In conclusion, the present test is reliable and sensitive, thus providing a sailing specific alternative to traditional physical testing of elite trapeze sailors. Additionally, on-water rac-ing requires moderate aerobic energy...

  1. Degradation Characterization of Thermal Interface Greases

    Energy Technology Data Exchange (ETDEWEB)

    Major, Joshua [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Narumanchi, Sreekant V [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Paret, Paul P [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Blackman, Gregory [DuPont; Wong, Arnold [DuPont; Meth, Jeffery [DuPont

    2018-02-12

    Thermal interface materials (TIMs) are used in power electronics packaging to minimize thermal resistance between the heat generating component and the heat sink. Thermal greases are one such class. The conformability and thin bond line thickness (BLT) of these TIMs can potentially provide low thermal resistance throughout the operation lifetime of a component. However, their performance degrades over time due to pump-out and dry-out during thermal and power cycling. The reliability performance of greases through operational cycling needs to be quantified to develop new materials with superior properties. NREL, in collaboration with DuPont, has performed thermal and reliability characterization of several commercially available thermal greases. Initial bulk and contact thermal resistance of grease samples were measured, and then the thermal degradation that occurred due to pump-out and dry-out during temperature cycling was monitored. The thermal resistances of five different grease materials were evaluated using NREL's steady-state thermal resistance tester based on the ASTM test method D5470. Greases were then applied, utilizing a 2.5 cm x 2.5 cm stencil, between invar and aluminum plates to compare the thermomechanical performance of the materials in a representative test fixture. Scanning Acoustic microscopy, thermal, and compositional analyses were performed periodically during thermal cycling from -40 degrees C to 125 degrees C. Completion of this characterization has allowed for a comprehensive evaluation of thermal greases both for their initial bulk and contact thermal performance, as well as their degradation mechanisms under accelerated thermal cycling conditions.

  2. Thermal Hydraulic Integral Effect Tests for Pressurized Water Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Baek, W. P.; Song, C. H.; Kim, Y. S. and others

    2005-02-15

    The objectives of the project are to construct a thermal-hydraulic integral effect test facility and to perform various integral effect tests for design, operation, and safety regulation of pressurized water reactors. During the first phase of this project (1997.8{approx}2002.3), the basic technology for thermal-hydraulic integral effect tests was established and the basic design of the test facility was accomplished: a full-height, 1/300-volume-scaled full pressure facility for APR1400, an evolutionary pressurized water reactor that was developed by Korean industry. Main objectives of the present phase (2002.4{approx}2005.2), was to optimize the facility design and to construct the experimental facility. We have performed following researches: 1) Optimization of the basic design of the thermal-hydraulic integral effect test facility for PWRs - ATLAS (Advanced Thermal-hydraulic Test Loop for Accident Simulation) - Reduced height design for APR1400 (+ specific design features of KSNP safety injection systems) - Thermal-hydraulic scaling based on three-level scaling methodology by Ishii et al. 2) Construction of the ATLAS facility - Detailed design of the test facility - Manufacturing and procurement of components - Installation of the facility 3) Development of supporting technology for integral effect tests - Development and application of advanced instrumentation technology - Preliminary analysis of test scenarios - Development of experimental procedures - Establishment and implementation of QA system/procedure.

  3. Thermal test requirements and their verification by different test methods

    International Nuclear Information System (INIS)

    Droste, B.; Wieser, G.; Probst, U.

    1993-01-01

    The paper discusses the parameters influencing the thermal test conditions for type B-packages. Criteria for different test methods (by analytical as well as by experimental means) will be developed. A comparison of experimental results from fuel oil pool and LPG fire tests will be given. (J.P.N.)

  4. Thermal tests of a transport / Storage cask in buried conditions

    International Nuclear Information System (INIS)

    Yamakawa, H.; Gomi, Y.; Saegusa, T.; Ito, C.

    1998-01-01

    Thermal tests for a hypothetical accident which simulated accidents caused by building collapse in case of an earthquake were conducted using a full-scale dry type transport and storage cask (total heat load: 23 kW). The objectives of these tests were to clarify the heat transfer features of the buried cask under such accidents and the time limit for maintaining the thermal integrity of the cask. Moreover, thermal analyses of the test cask under the buried conditions were carried out on basis of experimental results to establish methodology for the thermal analysis. The characteristics of the test cask are described as well as the test method used. The heat transfer features of the buried cask under such accidents and a time for maintaining the thermal integrity of the cask have been obtained. (O.M.)

  5. Inter-rater and intra-rater reliability of a movement control test in shoulder.

    Science.gov (United States)

    Rajasekar, S; Bangera, Rakshith K; Sekaran, Padmanaban

    2017-07-01

    Movement faults are commonly observed in patients with musculoskeletal pain. The Kinetic Medial Rotation Test (KMRT) is a movement control test used to identify movement faults of the scapula and gleno-humeral joints during arm movement. Objective tests such as the KMRT need to be reliable and valid for the results to be applied across different clinical settings and patient populations. The primary objective of the present study was to determine the intra-rater and inter-rater reliability of KMRT in subjects with and without shoulder pain. Sixty subjects were included in this study based on specific inclusion and exclusion criteria. Two musculoskeletal physiotherapists with different levels of clinical experience performed the tests. The intra-rater reliability was tested in twenty asymptomatic subjects by a single assessor at two week intervals. An equal number of subjects with and without shoulder pain were tested by both the assessors to determine the inter-rater reliability. Both components of the KMRT, the Gleno- Humeral Anterior Translation (GHAT) and the Scapular Forward Tilt (SCFT) were tested. The Kappa values for inter-rater reliability of the GHAT and SCFT were K = 0.68 & K = 0.65 respectively in subjects with shoulder pain. In asymptomatic subjects, the inter-rater reliability of GHAT was K = 0.61 and SCFT was K = 0.85. Intra-rater reliability ranged from K = 0.66 for GHAT to K = 0.87 for SCFT. Our study found substantial agreement in inter-rater reliability of KMRT in subjects with shoulder pain, whereas substantial to near perfect agreement was found in intra-rater and inter-rater reliability of KMRT in subjects without shoulder pain. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Test-retest and interobserver reliability of quantitative sensory testing according to the protocol of the German Research Network on Neuropathic Pain (DFNS): a multi-centre study.

    Science.gov (United States)

    Geber, Christian; Klein, Thomas; Azad, Shahnaz; Birklein, Frank; Gierthmühlen, Janne; Huge, Volker; Lauchart, Meike; Nitzsche, Dorothee; Stengel, Maike; Valet, Michael; Baron, Ralf; Maier, Christoph; Tölle, Thomas; Treede, Rolf-Detlef

    2011-03-01

    Quantitative sensory testing (QST) is an instrument to assess positive and negative sensory signs, helping to identify mechanisms underlying pathologic pain conditions. In this study, we evaluated the test-retest reliability (TR-R) and the interobserver reliability (IO-R) of QST in patients with sensory disturbances of different etiologies. In 4 centres, 60 patients (37 male and 23 female, 56.4±1.9years) with lesions or diseases of the somatosensory system were included. QST comprised 13 parameters including detection and pain thresholds for thermal and mechanical stimuli. QST was performed in the clinically most affected test area and a less or unaffected control area in a morning and an afternoon session on 2 consecutive days by examiner pairs (4 QSTs/patient). For both, TR-R and IO-R, there were high correlations (r=0.80-0.93) at the affected test area, except for wind-up ratio (TR-R: r=0.67; IO-R: r=0.56) and paradoxical heat sensations (TR-R: r=0.35; IO-R: r=0.44). Mean IO-R (r=0.83, 31% unexplained variance) was slightly lower than TR-R (r=0.86, 26% unexplained variance, Ptest area (TR-R: r=0.86; IO-R: r=0.83) than in the control area (TR-R: r=0.79; IO-R: r=0.71, each Preliability of QST. We conclude that standardized QST performed by trained examiners is a valuable diagnostic instrument with good test-retest and interobserver reliability within 2days. With standardized training, observer bias is much lower than random variance. Quantitative sensory testing performed by trained examiners is a valuable diagnostic instrument with good interobserver and test-retest reliability for use in patients with sensory disturbances of different etiologies to help identify mechanisms of neuropathic and non-neuropathic pain. Copyright © 2010 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.

  7. Development of seismic technology and reliability based on vibration tests

    International Nuclear Information System (INIS)

    Sasaki, Youichi

    1997-01-01

    This paper deals with some of the vibration tests and investigations on the seismic safety of nuclear power plants (NPPs) in Japan. To ensure the reliability of the seismic safety of nuclear power plants, nuclear power plants in Japan have been designed according to the Technical Guidelines for Aseismic Design of Nuclear Power Plants. This guideline has been developed based on technical date base and findings which were obtained from many vibration tests and investigations. Besides the tests for the guideline, proving tests on seismic reliability of operating nuclear power plants equipment and systems have been carried out. In this paper some vibration tests and their evaluation results are presented. They have crucially contributed to develop the guideline. (J.P.N.)

  8. Development of seismic technology and reliability based on vibration tests

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, Youichi [Nuclear Power Engineering Corp., Tokyo (Japan)

    1997-03-01

    This paper deals with some of the vibration tests and investigations on the seismic safety of nuclear power plants (NPPs) in Japan. To ensure the reliability of the seismic safety of nuclear power plants, nuclear power plants in Japan have been designed according to the Technical Guidelines for Aseismic Design of Nuclear Power Plants. This guideline has been developed based on technical date base and findings which were obtained from many vibration tests and investigations. Besides the tests for the guideline, proving tests on seismic reliability of operating nuclear power plants equipment and systems have been carried out. In this paper some vibration tests and their evaluation results are presented. They have crucially contributed to develop the guideline. (J.P.N.)

  9. Thermal Hydraulic Integral Effect Tests for Pressurized Water Reactors

    International Nuclear Information System (INIS)

    Baek, Won Pil; Song, C. H.; Kim, Y. S.

    2007-02-01

    The objectives of the project are to construct a thermal-hydraulic integral effect test facility and to perform the tests for design, operation, and safety regulation of pressurized water reactors. In the first phase of this project (1997.8∼2002.3), the basic technology for thermal-hydraulic integral effect tests was established and the basic design of the test facility was accomplished. In the second phase (2002.4∼2005.2), an optimized design of the ATLAS (Advanced Thermal-hydraulic Test Loop for Accident Simulation) was established and the construction of the facility was almost completed. In the third phase (2005.3∼2007.2), the construction and commission tests of the ATLAS are to be completed and some first-phase tests are to be conducted

  10. Application of a truncated normal failure distribution in reliability testing

    Science.gov (United States)

    Groves, C., Jr.

    1968-01-01

    Statistical truncated normal distribution function is applied as a time-to-failure distribution function in equipment reliability estimations. Age-dependent characteristics of the truncated function provide a basis for formulating a system of high-reliability testing that effectively merges statistical, engineering, and cost considerations.

  11. Reliability and validity of the revised Gibson Test of Cognitive Skills, a computer-based test battery for assessing cognition across the lifespan.

    Science.gov (United States)

    Moore, Amy Lawson; Miller, Terissa M

    2018-01-01

    The purpose of the current study is to evaluate the validity and reliability of the revised Gibson Test of Cognitive Skills, a computer-based battery of tests measuring short-term memory, long-term memory, processing speed, logic and reasoning, visual processing, as well as auditory processing and word attack skills. This study included 2,737 participants aged 5-85 years. A series of studies was conducted to examine the validity and reliability using the test performance of the entire norming group and several subgroups. The evaluation of the technical properties of the test battery included content validation by subject matter experts, item analysis and coefficient alpha, test-retest reliability, split-half reliability, and analysis of concurrent validity with the Woodcock Johnson III Tests of Cognitive Abilities and Tests of Achievement. Results indicated strong sources of evidence of validity and reliability for the test, including internal consistency reliability coefficients ranging from 0.87 to 0.98, test-retest reliability coefficients ranging from 0.69 to 0.91, split-half reliability coefficients ranging from 0.87 to 0.91, and concurrent validity coefficients ranging from 0.53 to 0.93. The Gibson Test of Cognitive Skills-2 is a reliable and valid tool for assessing cognition in the general population across the lifespan.

  12. Reliability of the Handgrip Strength Test in Elderly Subjects With Parkinson Disease.

    Science.gov (United States)

    Villafañe, Jorge H; Valdes, Kristin; Buraschi, Riccardo; Martinelli, Marco; Bissolotti, Luciano; Negrini, Stefano

    2016-03-01

    The handgrip strength test is widely used by clinicians; however, little has been investigated about its reliability when used in subjects with Parkinson disease (PD). The purpose of this study was to investigate the test-retest reliability of the handgrip strength test for subjects with PD. The PD group consisted of 15 patients, and the control group consisted of 15 healthy subjects. Each patient performed 3 pain-free maximal isometric contractions on each hand on 2 occasions, 1 week apart. Intraclass correlation coefficient (ICC), standard error of measurement (SEM), and 95% limits of agreement (LOA) were calculated. The 2-way analysis of variance (ANOVA) was conducted to determine the differences between sides and groups. Test-retest reliability of measurements of grip strength was excellent for dominant (ICC = 0.97; P = .001) and non-dominant (ICC = 0.98; P = .001) hand of participant with PD and (ICC = 0.99; P = .001) and (ICC = 0.99; P = .001) respectively, of healthy group. The Jamar hand dynamometer had fair to excellent test-retest reliability to test grip strength in participants with PD.

  13. First reliability test of a surface micromachined microengine using SHiMMeR

    Energy Technology Data Exchange (ETDEWEB)

    Tanner, D.M.; Smith, N.F.; Bowman, D.J. [and others

    1997-08-01

    The first-ever reliability stress test on surface micromachined microengines developed at Sandia National Laboratories (SNL) has been completed. We stressed 41 microengines at 36,000 RPM and inspected the functionality at 60 RPM. We have observed an infant mortality region, a region of low failure rate (useful life), and no signs of wearout in the data. The reliability data are presented and interpreted using standard reliability methods. Failure analysis results on the stressed microengines are presented. In our effort to study the reliability of MEMS, we need to observe the failures of large numbers of parts to determine the failure modes. To facilitate testing of large numbers of micromachines. The Sandia High Volume Measurement of Micromachine Reliability (SHiMMeR) system has computer controlled positioning and the capability to inspect moving parts. The development of this parallel testing system is discussed in detail.

  14. Data report of BWR post-CHF tests. Transient core thermal-hydraulic test program. Contract research

    International Nuclear Information System (INIS)

    Iguchi, Tadashi; Itoh, Hideo; Kiuchi, Toshio; Watanabe, Hironori; Kimura, Mamoru; Anoda, Yoshinari

    2001-03-01

    JAERI has been performing transient core thermal-hydraulic test program. In the program, authors performed BWR/ABWR DBE simulation tests with a test facility, which can simulate BWR/ABWR transients. The test facility has a 4 x 4 bundle core simulator with 15-rod heaters and one non-heated rod. Through the tests, authors quantified the thermal safety margin for core cooling. In order to quantify the thermal safety margin, authors collected experimental data on post-CHF. The data are essential for the evaluation of clad temperature transient when core heat-up occurs during DBEs. In comparison with previous post-CHF tests, present experiments were performed in much wider experimental condition, covering high clad temperature, low to high pressure and low to high mass flux. Further, data at wider elevation (lower to higher elevation of core) were obtained in the present experiments, which make possible to discuss the effect of axial position on thermal-hydraulics, while previous works usually discuss the thermal-hydraulics at the position where the first heat-up occurs. This data report describes test procedure, test condition and major experimental data of post-CHF tests. (author)

  15. Validity and test-retest reliability of a novel simple back extensor muscle strength test.

    Science.gov (United States)

    Harding, Amy T; Weeks, Benjamin Kurt; Horan, Sean A; Little, Andrew; Watson, Steven L; Beck, Belinda Ruth

    2017-01-01

    To develop and determine convergent validity and reliability of a simple and inexpensive clinical test to quantify back extensor muscle strength. Two testing sessions were conducted, 7 days apart. Each session involved three trials of standing maximal isometric back extensor muscle strength using both the novel test and isokinetic dynamometry. Lumbar spine bone mineral density was examined by dual-energy X-ray absorptiometry. Validation was examined with Pearson correlations ( r ). Test-retest reliability was examined with intraclass correlation coefficients and limits of agreement. Pearson correlations and intraclass correlation coefficients are presented with corresponding 95% confidence intervals. Linear regression was used to examine the ability of peak back extensor muscle strength to predict indices of lumbar spine bone mineral density and strength. A total of 52 healthy adults (26 men, 26 women) aged 46.4 ± 20.4 years were recruited from the community. A strong positive relationship was observed between peak back extensor strength from hand-held and isokinetic dynamometry ( r  = 0.824, p  strength test, short- and long-term reliability was excellent (intraclass correlation coefficient = 0.983 (95% confidence interval, 0.971-0.990), p  strength measures with the novel back extensor strength protocol were -6.63 to 7.70 kg, with a mean bias of +0.71 kg. Back extensor strength predicted 11% of variance in lumbar spine bone mineral density ( p  strength ( p  strength is quick, relatively inexpensive, and reliable; demonstrates initial convergent validity in a healthy population; and is associated with bone mass at a clinically important site.

  16. Isokinetic Strength and Endurance Tests used Pre- and Post-Spaceflight: Test-Retest Reliability

    Science.gov (United States)

    Laughlin, Mitzi S.; Lee, Stuart M. C.; Loehr, James A.; Amonette, William E.

    2009-01-01

    To assess changes in muscular strength and endurance after microgravity exposure, NASA measures isokinetic strength and endurance across multiple sessions before and after long-duration space flight. Accurate interpretation of pre- and post-flight measures depends upon the reliability of each measure. The purpose of this study was to evaluate the test-retest reliability of the NASA International Space Station (ISS) isokinetic protocol. Twenty-four healthy subjects (12 M/12 F, 32.0 +/- 5.6 years) volunteered to participate. Isokinetic knee, ankle, and trunk flexion and extension strength as well as endurance of the knee flexors and extensors were measured using a Cybex NORM isokinetic dynamometer. The first weekly session was considered a familiarization session. Data were collected and analyzed for weeks 2-4. Repeated measures analysis of variance (alpha=0.05) was used to identify weekly differences in isokinetic measures. Test-retest reliability was evaluated by intraclass correlation coefficients (ICC) (3,1). No significant differences were found between weeks in any of the strength measures and the reliability of the strength measures were all considered excellent (ICC greater than 0.9), except for concentric ankle dorsi-flexion (ICC=0.67). Although a significant difference was noted in weekly endurance measures of knee extension (p less than 0.01), the reliability of endurance measure by week were considered excellent for knee flexion (ICC=0.97) and knee extension (ICC=0.96). Except for concentric ankle dorsi-flexion, the isokinetic strength and endurance measures are highly reliable when following the NASA ISS protocol. This protocol should allow accurate interpretation isokinetic data even with a small number of crew members.

  17. Separate effects tests to determine the effective thermal conductivity in the PBMR HTTU test facility

    Energy Technology Data Exchange (ETDEWEB)

    Rousseau, P.G., E-mail: pgr@mtechindustrial.com [School of Mechanical and Nuclear Engineering, North-West University, Private Bag X6001, Potchefstroom 2520 (South Africa); Toit, C.G. du; Antwerpen, W. van [School of Mechanical and Nuclear Engineering, North-West University, Private Bag X6001, Potchefstroom 2520 (South Africa); Antwerpen, H.J. van [M-Tech Industrial (Pty) Ltd., PO Box 19855, Noordbrug 2522 (South Africa)

    2014-05-01

    Thermal-fluid simulations are used extensively to predict the maximum fuel temperatures, flows, pressure drops and thermal capacitance of pebble bed gas cooled reactors in support of the reactor safety case. The PBMR company developed the HTTU non-nuclear test facility in cooperation with M-Tech Industrial (Pty) Ltd. and the North-West University in South Africa to conduct comprehensive separate effects tests as well as integrated effects tests to study the different thermal-fluid phenomena. This paper describes the separate effects tests that were conducted to determine the effective thermal conductivity through the pebble bed under near-vacuum conditions and temperatures up to 1200 °C. It also presents the measured temperature distributions and the methodology applied in the data analysis to derive the resultant values of effective thermal conductivity and its associated uncertainty.

  18. Separate effects tests to determine the effective thermal conductivity in the PBMR HTTU test facility

    International Nuclear Information System (INIS)

    Rousseau, P.G.; Toit, C.G. du; Antwerpen, W. van; Antwerpen, H.J. van

    2014-01-01

    Thermal-fluid simulations are used extensively to predict the maximum fuel temperatures, flows, pressure drops and thermal capacitance of pebble bed gas cooled reactors in support of the reactor safety case. The PBMR company developed the HTTU non-nuclear test facility in cooperation with M-Tech Industrial (Pty) Ltd. and the North-West University in South Africa to conduct comprehensive separate effects tests as well as integrated effects tests to study the different thermal-fluid phenomena. This paper describes the separate effects tests that were conducted to determine the effective thermal conductivity through the pebble bed under near-vacuum conditions and temperatures up to 1200 °C. It also presents the measured temperature distributions and the methodology applied in the data analysis to derive the resultant values of effective thermal conductivity and its associated uncertainty

  19. Thermal testing of packages for transport of radioactive wastes

    International Nuclear Information System (INIS)

    Koski, J.A.

    1994-01-01

    Shipping containers for radioactive materials must be shown capable of surviving tests specified by regulations such as Title 10, Code of Federal Regulations, Part 71 (called 10CFR71 in this paper) within the United States. Equivalent regulations hold for other countries such as Safety Series 6 issued by the International Atomic Energy Agency. The containers must be shown to be capable of surviving, in order, drop tests, puncture tests, and thermal tests. Immersion testing in water is also required, but must be demonstrated for undamaged packages. The thermal test is intended to simulate a 30 minute exposure to a fully engulfing pool fire that could occur if a transport accident involved the spill of large quantities of hydrocarbon fuels. Various qualification methods ranging from pure analysis to actual pool fire tests have been used to prove regulatory compliance. The purpose of this paper is to consider the alternatives for thermal testing, point out the strengths and weaknesses of each approach, and to provide the designer with the information necessary to make informed decisions on the proper test program for the particular shipping container under consideration. While thermal analysis is an alternative to physical testing, actual testing is often emphasized by regulators, and this report concentrates on these testing alternatives

  20. Reliability of the Test of Wheeled Mobility (TOWM) and the Short Wheelie Test

    NARCIS (Netherlands)

    Fliess-Douer, Osnat; Van der Woude, Lucas H. V.; Vanlandewijck, Yves C.

    Objective: To assess the reliability of the Test of Wheeled Mobility (TOWM) and the Wheelie test. Design: Cohort study. Setting: Gymnasium. Participants: Manual wheelchair users (N=30, age 23-53y) with a spinal cord injury. Intervention: Participants performed the 30 skills of the TOWM and the 8

  1. Reliability and maintainability data acquisition in equipment development tests

    International Nuclear Information System (INIS)

    Haire, M.J.; Gift, E.H.

    1983-10-01

    The need for collection of reliability, maintainability, and availability data adds a new dimension to the data acquisition requirements of equipment development tests. This report describes the reliability and maintainability data that are considered necessary to ensure that sufficient and high quality data exist for a comprehensive, quantitative evaluation of equipment and system availability. These necessary data are presented as a set of data collection forms. Three data acquisition forms are discussed: an inventory and technical data form, which is filed by the design engineer when the design is finished or the equipment is received; an event report form, which is completed by the senior test operator at each shutdown; and a maintainability report, which is a collaborative effort between senior operators and lead engineers and is completed on restart. In addition, elements of a reliability, maintainability evaluation program are described. Emphasis is placed on the role of data, its storage, and use in such a program

  2. James Webb Space Telescope Core 2 Test - Cryogenic Thermal Balance Test of the Observatorys Core Area Thermal Control Hardware

    Science.gov (United States)

    Cleveland, Paul; Parrish, Keith; Thomson, Shaun; Marsh, James; Comber, Brian

    2016-01-01

    The James Webb Space Telescope (JWST), successor to the Hubble Space Telescope, will be the largest astronomical telescope ever sent into space. To observe the very first light of the early universe, JWST requires a large deployed 6.5-meter primary mirror cryogenically cooled to less than 50 Kelvin. Three scientific instruments are further cooled via a large radiator system to less than 40 Kelvin. A fourth scientific instrument is cooled to less than 7 Kelvin using a combination pulse-tube Joule-Thomson mechanical cooler. Passive cryogenic cooling enables the large scale of the telescope which must be highly folded for launch on an Ariane 5 launch vehicle and deployed once on orbit during its journey to the second Earth-Sun Lagrange point. Passive cooling of the observatory is enabled by the deployment of a large tennis court sized five layer Sunshield combined with the use of a network of high efficiency radiators. A high purity aluminum heat strap system connects the three instrument's detector systems to the radiator systems to dissipate less than a single watt of parasitic and instrument dissipated heat. JWST's large scale features, while enabling passive cooling, also prevent the typical flight configuration fully-deployed thermal balance test that is the keystone of most space missions' thermal verification plans. This paper describes the JWST Core 2 Test, which is a cryogenic thermal balance test of a full size, high fidelity engineering model of the Observatory's 'Core' area thermal control hardware. The 'Core' area is the key mechanical and cryogenic interface area between all Observatory elements. The 'Core' area thermal control hardware allows for temperature transition of 300K to approximately 50 K by attenuating heat from the room temperature IEC (instrument electronics) and the Spacecraft Bus. Since the flight hardware is not available for test, the Core 2 test uses high fidelity and flight-like reproductions.

  3. Diagnosis of carpal tunnel syndrome: interobserver reliability of the blinded scratch-collapse test

    NARCIS (Netherlands)

    Blok, Robin D.; Becker, Stéphanie J. E.; Ring, David C.

    2014-01-01

    The reliability of the scratch-collapse test for diagnosis of carpal tunnel syndrome (CTS) has not been tested by independent investigators. This study measured the reliability of the scratch-collapse test comparing the treating hand surgeon and blinded evaluators. We performed a prospective

  4. Investigation of low glass transition temperature on COTS PEMs reliability

    Science.gov (United States)

    Sandor, M.; Agarwal, S.

    2002-01-01

    Many factors influence PEM component reliability.One of the factors that can affect PEM performance and reliability is the glass transition temperature (Tg) and the coefficient of thermal expansion (CTE) of the encapsulant or underfill. JPL/NASA is investigating how the Tg and CTE for PEMs affect device reliability under different temperature and aging conditions. Other issues with Tg are also being investigated. Some preliminary data will be presented on glass transition temperature test results conducted at JPL.

  5. Test-retest reliability of the Danish Adult Reading Test in patients with comorbid psychosis and cannabis-use disorder

    DEFF Research Database (Denmark)

    Hjorthøj, Carsten Rygaard; Vesterager, Lone; Nordentoft, Merete

    2013-01-01

    Background: The New Adult Reading Test is a common instrument for assessing pre-morbid IQ for patients with, for instance, schizophrenia. However, test-retest reliability has not been established for patients dually diagnosed with psychosis and substance use disorder. Furthermore, test......-retest reliability of the Danish adaptation has never been established in any population. Aims: To determine the test-retest reliability of the Danish Adult Reading Test (DART) (adapted from the National Adult Reading Test, NART) for patients dually diagnosed with psychosis and cannabis-use disorder. Methods......: This was a secondary analysis of the CapOpus randomized trial. As part of the trial, 103 patients were randomized, and completed the DART up to three times. Pearson's r and pairwise t-tests were calculated. Results: DART score was independent of randomization, cannabis-use frequency and psychopathology. Scores...

  6. Fast and thermal data testing of 233U critical assemblies

    International Nuclear Information System (INIS)

    Wright, R.Q.; Jordan, W.C.; Leal, L.C.

    1999-01-01

    Many sources have been used to obtain 233 U benchmark descriptions. Unfortunately, some of these are not reliable since a thorough and complete benchmark evaluation often has not been done. For 24 yr a principal source for 233 U benchmarks has been the Cross Section Evaluation Working Group (CSEWG) Benchmark Specifications. The CSEWG specifications included only two fast benchmarks and three thermal benchmarks. The thermal benchmarks were H 2 O-moderated thorium-oxide exponential lattices. Since the thorium-oxide lattices were exponential experiments, they have not been widely used. CSEWG has also used the 233 U Oak Ridge National Laboratory (ORNL) spheres for many years. One advantage of the CSEWG fast benchmarks, JEZEBEL-23 and FLATTOP-23, is that experiments were done for central-reaction-rate ratios. These reaction-rate ratios provide very valuable information to data testers and evaluators that would not otherwise be available. In recent years the International Handbook of Evaluated Criticality Safety Benchmark Experiments has, in general, been a very useful and reliable source. The Handbook does not include central-reaction-rate ratio experiments, however. A new set of 233 U benchmark experiments has been added to the most recent release of the Handbook, U233-SOL-THERM-004. These are paraffin-reflected cylinders of 233 U uranyl-nitrate solutions. Unfortunately, the estimated benchmark uncertainties are on the order of 0.9 to 1.0% in k eff . Benchmark testing has been done for some of these U233-SOL-THERM-004 experiments. The authors have also discovered that the benchmark specifications for the Thomas uranyl-nitrate experiments given in Ref. 5 are incorrect. One problem with the Ref. 5 specifications is that the excess acid was not included. As part of this work, the authors developed revised specifications that include an excess acid correlation based on information from the experimental logbook

  7. Reliability of physical functioning tests in patients with low back pain: a systematic review.

    Science.gov (United States)

    Denteneer, Lenie; Van Daele, Ulrike; Truijen, Steven; De Hertogh, Willem; Meirte, Jill; Stassijns, Gaetane

    2018-01-01

    The aim of this study was to provide a comprehensive overview of physical functioning tests in patients with low back pain (LBP) and to investigate their reliability. A systematic computerized search was finalized in four different databases on June 24, 2017: PubMed, Web of Science, Embase, and MEDLINE. Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines were followed during all stages of this review. Clinical studies that investigate the reliability of physical functioning tests in patients with LBP were eligible. The methodological quality of the included studies was assessed with the use of the Consensus-based Standards for the selection of health Measurement Instruments (COSMIN) checklist. To come to final conclusions on the reliability of the identified clinical tests, the current review assessed three factors, namely, outcome assessment, methodological quality, and consistency of description. A total of 20 studies were found eligible and 38 clinical tests were identified. Good overall test-retest reliability was concluded for the extensor endurance test (intraclass correlation coefficient [ICC]=0.93-0.97), the flexor endurance test (ICC=0.90-0.97), the 5-minute walking test (ICC=0.89-0.99), the 50-ft walking test (ICC=0.76-0.96), the shuttle walk test (ICC=0.92-0.99), the sit-to-stand test (ICC=0.91-0.99), and the loaded forward reach test (ICC=0.74-0.98). For inter-rater reliability, only one test, namely, the Biering-Sörensen test (ICC=0.88-0.99), could be concluded to have an overall good inter-rater reliability. None of the identified clinical tests could be concluded to have a good intrarater reliability. Further investigation should focus on a better overall study methodology and the use of identical protocols for the description of clinical tests. The assessment of reliability is only a first step in the recommendation process for the use of clinical tests. In future research, the identified clinical tests in the

  8. A test chip for automatic reliability measurements of interconnect vias

    NARCIS (Netherlands)

    Lippe, K.; Hasper, A.; Elfrink, G.W.; Niehof, J.; Kerkhoff, Hans G.

    1992-01-01

    A test circuit for electromigration reliability measurements was designed and tested. The device under test (DUT) is a via-hole chain. The test circuit permits simultaneous measurements of a number of DUTs, and a fatal error of one DUT does not influence the measurement results of the other DUTs.

  9. Applications of majorization and Schur functions in reliability and life testing

    International Nuclear Information System (INIS)

    Proschan, F.

    1975-01-01

    This is an expository paper presenting basic definitions and properties of majorization and Schur functions, and displaying a variety of applications of these concepts in reliability prediction and modelling, and in reliability inference and life testing

  10. NDE reliability gains from combining eddy-current and ultrasonic testing

    International Nuclear Information System (INIS)

    Horn, D.; Mayo, W.R.

    1999-01-01

    We investigate statistical methods for combining the results of two complementary inspection techniques, eddy-current and ultrasonic testing. The reliability of rejection/acceptance decisions based on combined information is compared with that based on each inspection technique individually. The measured reliability increases with the amount of information incorporated in the decision. (author)

  11. Validity and Reliability Study of the Korean Tinetti Mobility Test for Parkinson's Disease.

    Science.gov (United States)

    Park, Jinse; Koh, Seong-Beom; Kim, Hee Jin; Oh, Eungseok; Kim, Joong-Seok; Yun, Ji Young; Kwon, Do-Young; Kim, Younsoo; Kim, Ji Seon; Kwon, Kyum-Yil; Park, Jeong-Ho; Youn, Jinyoung; Jang, Wooyoung

    2018-01-01

    Postural instability and gait disturbance are the cardinal symptoms associated with falling among patients with Parkinson's disease (PD). The Tinetti mobility test (TMT) is a well-established measurement tool used to predict falls among elderly people. However, the TMT has not been established or widely used among PD patients in Korea. The purpose of this study was to evaluate the reliability and validity of the Korean version of the TMT for PD patients. Twenty-four patients diagnosed with PD were enrolled in this study. For the interrater reliability test, thirteen clinicians scored the TMT after watching a video clip. We also used the test-retest method to determine intrarater reliability. For concurrent validation, the unified Parkinson's disease rating scale, Hoehn and Yahr staging, Berg Balance Scale, Timed-Up and Go test, 10-m walk test, and gait analysis by three-dimensional motion capture were also used. We analyzed receiver operating characteristic curve to predict falling. The interrater reliability and intrarater reliability of the Korean Tinetti balance scale were 0.97 and 0.98, respectively. The interrater reliability and intra-rater reliability of the Korean Tinetti gait scale were 0.94 and 0.96, respectively. The Korean TMT scores were significantly correlated with the other clinical scales and three-dimensional motion capture. The cutoff values for predicting falling were 14 points (balance subscale) and 10 points (gait subscale). We found that the Korean version of the TMT showed excellent validity and reliability for gait and balance and had high sensitivity and specificity for predicting falls among patients with PD.

  12. Development of an Agility Test for Badminton Players and Assessment of Its Validity and Test-Retest Reliability.

    Science.gov (United States)

    Loureiro, Luiz de França Bahia; de Freitas, Paulo Barbosa

    2016-04-01

    Badminton requires open and fast actions toward the shuttlecock, but there is no specific agility test for badminton players with specific movements. To develop an agility test that simultaneously assesses perception and motor capacity and examine the test's concurrent and construct validity and its test-retest reliability. The Badcamp agility test consists of running as fast as possible to 6 targets placed on the corners and middle points of a rectangular area (5.6 × 4.2 m) from the start position located in the center of it, following visual stimuli presented in a luminous panel. The authors recruited 43 badminton players (17-32 y old) to evaluate concurrent (with shuttle-run agility test--SRAT) and construct validity and test-retest reliability. Results revealed that Badcamp presents concurrent and construct validity, as its performance is strongly related to SRAT (ρ = 0.83, P < .001), with performance of experts being better than nonexpert players (P < .01). In addition, Badcamp is reliable, as no difference (P = .07) and a high intraclass correlation (ICC = .93) were found in the performance of the players on 2 different occasions. The findings indicate that Badcamp is an effective, valid, and reliable tool to measure agility, allowing coaches and athletic trainers to evaluate players' athletic condition and training effectiveness and possibly detect talented individuals in this sport.

  13. Thermal cycling reliability of Cu/SnAg double-bump flip chip assemblies for 100 μm pitch applications

    Science.gov (United States)

    Son, Ho-Young; Kim, Ilho; Lee, Soon-Bok; Jung, Gi-Jo; Park, Byung-Jin; Paik, Kyung-Wook

    2009-01-01

    A thick Cu column based double-bump flip chip structure is one of the promising alternatives for fine pitch flip chip applications. In this study, the thermal cycling (T/C) reliability of Cu/SnAg double-bump flip chip assemblies was investigated, and the failure mechanism was analyzed through the correlation of T/C test and the finite element analysis (FEA) results. After 1000 thermal cycles, T/C failures occurred at some Cu/SnAg bumps located at the edge and corner of chips. Scanning acoustic microscope analysis and scanning electron microscope observations indicated that the failure site was the Cu column/Si chip interface. It was identified by a FEA where the maximum stress concentration was located during T/C. During T/C, the Al pad between the Si chip and a Cu column bump was displaced due to thermomechanical stress. Based on the low cycle fatigue model, the accumulation of equivalent plastic strain resulted in thermal fatigue deformation of the Cu column bumps and ultimately reduced the thermal cycling lifetime. The maximum equivalent plastic strains of some bumps at the chip edge increased with an increased number of thermal cycles. However, equivalent plastic strains of the inner bumps did not increase regardless of the number of thermal cycles. In addition, the z-directional normal plastic strain ɛ22 was determined to be compressive and was a dominant component causing the plastic deformation of Cu/SnAg double bumps. As the number of thermal cycles increased, normal plastic strains in the perpendicular direction to the Si chip and shear strains were accumulated on the Cu column bumps at the chip edge at low temperature region. Thus it was found that the Al pad at the Si chip/Cu column interface underwent thermal fatigue deformation by compressive normal strain and the contact loss by displacement failure of the Al pad, the main T/C failure mode of the Cu/SnAg flip chip assembly, then occurred at the Si chip/Cu column interface shear strain deformation

  14. Validity, Reliability and Standardization Study of the Language Assessment Test for Aphasia

    Directory of Open Access Journals (Sweden)

    Bülent Toğram

    2012-09-01

    Full Text Available OBJECTIVE: Aphasia assessment is the first step towards a well- founded language therapy. Language tests need to consider cultural as well as typological linguistic aspects of a given language. This study was designed to determine the standardization, validity and reliability of Language Assessment Test for Aphasia, which consists of eight subtests including spontaneous speech and language, auditory comprehension, repetition, naming, reading, grammar, speech acts, and writing. METHODS: The test was administered to 282 healthy participants and 92 aphasic participants in age, education and gender matched groups. The validity study of the test was investigated with analysis of content, structure and criterion-related validity. For reliability of the test, the analysis of internal consistency, stability and equivalence reliability was conducted. The influence of variables on healhty participants’ sub-test scores, test score and language score was examined. According to significant differences, norms and cut-off scores based on language score were determined. RESULTS: The group with aphasia performed highly lower than healthy participants on subtest, test and language scores. The test scores of healthy group were mostly affected by age and educational level but not affected by gender. According to significant differences, age and educational level for both groups were determined. Considering age and educational levels, the reference values for the cut-off scores were presented. CONCLUSION: The test was found to be a highly reliable and valid aphasia test for Turkish- speaking aphasic patients either in Turkey or other Turkish communities around the world

  15. Reliability of a science admission test (HAM-Nat) at Hamburg medical school.

    Science.gov (United States)

    Hissbach, Johanna; Klusmann, Dietrich; Hampe, Wolfgang

    2011-01-01

    The University Hospital in Hamburg (UKE) started to develop a test of knowledge in natural sciences for admission to medical school in 2005 (Hamburger Auswahlverfahren für Medizinische Studiengänge, Naturwissenschaftsteil, HAM-Nat). This study is a step towards establishing the HAM-Nat. We are investigating parallel forms reliability, the effect of a crash course in chemistry on test results, and correlations of HAM-Nat test results with a test of scientific reasoning (similar to a subtest of the "Test for Medical Studies", TMS). 316 first-year students participated in the study in 2007. They completed different versions of the HAM-Nat test which consisted of items that had already been used (HN2006) and new items (HN2007). Four weeks later half of the participants were tested on the HN2007 version of the HAM-Nat again, while the other half completed the test of scientific reasoning. Within this four week interval students were offered a five day chemistry course. Parallel forms reliability for four different test versions ranged from r(tt)=.53 to r(tt)=.67. The retest reliabilities of the HN2007 halves were r(tt)=.54 and r(tt )=.61. Correlations of the two HAM-Nat versions with the test of scientific reasoning were r=.34 und r=.21. The crash course in chemistry had no effect on HAM-Nat scores. The results suggest that further versions of the test of natural sciences will not easily conform to the standards of internal consistency, parallel-forms reliability and retest reliability. Much care has to be taken in order to assemble items which could be used interchangeably for the construction of new test versions. The test of scientific reasoning and the HAM-Nat are tapping different constructs. Participation in a chemistry course did not improve students' achievement, probably because the content of the course was not coordinated with the test and many students lacked of motivation to do well in the second test.

  16. Thermal Vacuum Test Correlation of A Zero Propellant Load Case Thermal Capacitance Propellant Gauging Analytics Model

    Science.gov (United States)

    McKim, Stephen A.

    2016-01-01

    This thesis describes the development and test data validation of the thermal model that is the foundation of a thermal capacitance spacecraft propellant load estimator. Specific details of creating the thermal model for the diaphragm propellant tank used on NASA's Magnetospheric Multiscale spacecraft using ANSYS and the correlation process implemented to validate the model are presented. The thermal model was correlated to within plus or minus 3 degrees Centigrade of the thermal vacuum test data, and was found to be relatively insensitive to uncertainties in applied heat flux and mass knowledge of the tank. More work is needed, however, to refine the thermal model to further improve temperature predictions in the upper hemisphere of the propellant tank. Temperatures predictions in this portion were found to be 2-2.5 degrees Centigrade lower than the test data. A road map to apply the model to predict propellant loads on the actual MMS spacecraft toward its end of life in 2017-2018 is also presented.

  17. Degradation Characterization of Thermal Interface Greases: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    DeVoto, Douglas J [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Major, Joshua [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Paret, Paul P [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Blackman, G. S. [DuPont Experimental Station; Wong, A. [DuPont Experimental Station; Meth, J. S. [DuPont Experimental Station

    2017-08-03

    Thermal interface materials (TIMs) are used in power electronics packaging to minimize thermal resistance between the heat generating component and the heat sink. Thermal greases are one such class. The conformability and thin bond line thickness (BLT) of these TIMs can potentially provide low thermal resistance throughout the operation lifetime of a component. However, their performance degrades over time due to pump-out and dry-out during thermal and power cycling. The reliability performance of greases through operational cycling needs to be quantified to develop new materials with superior properties. NREL, in collaboration with DuPont, has performed thermal and reliability characterization of several commercially available thermal greases. Initial bulk and contact thermal resistance of grease samples were measured, and then the thermal degradation that occurred due to pump-out and dry-out during temperature cycling was monitored. The thermal resistances of five different grease materials were evaluated using NREL's steady-state thermal resistance tester based on the ASTM test method D5470. Greases were then applied, utilizing a 2.5 cm x 2.5 cm stencil, between invar and aluminum plates to compare the thermomechanical performance of the materials in a representative test fixture. Scanning Acoustic microscopy, thermal, and compositional analyses were performed periodically during thermal cycling from -40 degrees Celcius to 125 degrees Celcius. Completion of this characterization has allowed for a comprehensive evaluation of thermal greases both for their initial bulk and contact thermal performance, as well as their degradation mechanisms under accelerated thermal cycling conditions.

  18. A RELIABILITY TEST USED FOR THE DEVELOPMENT OF A LOYALTY SCALE

    Directory of Open Access Journals (Sweden)

    Florin-Alexandru LUCA

    2017-06-01

    Full Text Available The development of a loyalty model involves the construction of a proper research instrument. For the loyalty model of the clients for financial services, the pre-testing of the research questionnaire represents a significant stage. This article presents the methodology used in this stage for testing the reliability of a loyalty scale. Firstly, this implies choosing the appropriate scales for each variable included in the suggested research model. Secondly, the internal consistency for each of these scales is measured as an indicator of their reliability. The reliability analysis described represents an essential stage in building a measurement instrument for a loyalty model.

  19. The role of test-retest reliability in measuring individual and group differences in executive functioning.

    Science.gov (United States)

    Paap, Kenneth R; Sawi, Oliver

    2016-12-01

    Studies testing for individual or group differences in executive functioning can be compromised by unknown test-retest reliability. Test-retest reliabilities across an interval of about one week were obtained from performance in the antisaccade, flanker, Simon, and color-shape switching tasks. There is a general trade-off between the greater reliability of single mean RT measures, and the greater process purity of measures based on contrasts between mean RTs in two conditions. The individual differences in RT model recently developed by Miller and Ulrich was used to evaluate the trade-off. Test-retest reliability was statistically significant for 11 of the 12 measures, but was of moderate size, at best, for the difference scores. The test-retest reliabilities for the Simon and flanker interference scores were lower than those for switching costs. Standard practice evaluates the reliability of executive-functioning measures using split-half methods based on data obtained in a single day. Our test-retest measures of reliability are lower, especially for difference scores. These reliability measures must also take into account possible day effects that classical test theory assumes do not occur. Measures based on single mean RTs tend to have acceptable levels of reliability and convergent validity, but are "impure" measures of specific executive functions. The individual differences in RT model shows that the impurity problem is worse than typically assumed. However, the "purer" measures based on difference scores have low convergent validity that is partly caused by deficiencies in test-retest reliability. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. CERN Technical training 2008 - Learning for the LHC: Special Workshop demonstrating reliability with accelerated testing

    CERN Multimedia

    2008-01-01

    Larry Edson’s workshop will show examples of quantitative reliability predictions based upon accelerated testing and demonstrates that reliability testing during the prototyping phase will help ascertain product shortcomings. When these weak points are addressed and the redesigned product is re-tested, the reliability of that product will become much higher. These methodologies successfully used in industry might be exceedingly useful also for component development in particle physics where reliability is of utmost importance. This training will provide participants with the skills necessary to demonstrate reliability requirements using accelerated testing methods. The workshop will focus on accelerated test design that employs increased stress levels. This approach has the advantage of reducing test time, sample size and test facility resources. The methodologies taught are applicable to all types of stresses, spanning the electro...

  1. CERN Technical training 2008 - Learning for the LHC: Special Workshop demonstrating reliability with accelerated testing

    CERN Multimedia

    2008-01-01

    Larry Edson’s workshop will show examples of quantitative reliability predictions based upon accelerated testing and demonstrate that reliability testing during the prototyping phase will help ascertain product shortcomings. When these weak points are addressed and the redesigned product is re-tested, the reliability of that product will become much higher. These methodologies successfully used in industry might be exceedingly useful also for component development in particle physics where reliability is of the utmost importance. This training will provide participants with the skills necessary to demonstrate reliability requirements using accelerated testing methods. The workshop will focus on accelerated test design that employs increased stress levels. This approach has the advantage of reducing test time, sample size and test facility resources. The methodologies taught are applicable to all types of stresses, spanning the elec...

  2. CERN Technical training 2008 - Learning for the LHC: Special workshop demonstrating reliability with accelerated testing

    CERN Multimedia

    2008-01-01

    Larry Edson’s workshop will show examples of quantitative reliability predictions based upon accelerated testing and demonstrate that reliability testing during the prototyping phase will help ascertain product shortcomings. When these weak points are addressed and the redesigned product is re-tested, the reliability of that product will become much higher. These methodologies successfully used in industry might be exceedingly useful also for component development in particle physics where reliability is of the utmost importance. This training will provide participants with the skills necessary to demonstrate reliability requirements using accelerated testing methods. The workshop will focus on accelerated test design that employs increased stress levels. This approach has the advantage of reducing test time, sample size and test facility resources. The methodologies taught are applicable to all types of stresses, spanning the elec...

  3. Reliability and Validity of the Inline Skating Skill Test

    Science.gov (United States)

    Radman, Ivan; Ruzic, Lana; Padovan, Viktoria; Cigrovski, Vjekoslav; Podnar, Hrvoje

    2016-01-01

    This study aimed to examine the reliability and validity of the inline skating skill test. Based on previous skating experience forty-two skaters (26 female and 16 male) were randomized into two groups (competitive level vs. recreational level). They performed the test four times, with a recovery time of 45 minutes between sessions. Prior to testing, the participants rated their skating skill using a scale from 1 to 10. The protocol included performance time measurement through a course, combining different skating techniques. Trivial changes in performance time between the repeated sessions were determined in both competitive females/males and recreational females/males (-1.7% [95% CI: -5.8–2.6%] – 2.2% [95% CI: 0.0–4.5%]). In all four subgroups, the skill test had a low mean within-individual variation (1.6% [95% CI: 1.2–2.4%] – 2.7% [95% CI: 2.1–4.0%]) and high mean inter-session correlation (ICC = 0.97 [95% CI: 0.92–0.99] – 0.99 [95% CI: 0.98–1.00]). The comparison of detected typical errors and smallest worthwhile changes (calculated as standard deviations × 0.2) revealed that the skill test was able to track changes in skaters’ performances. Competitive-level skaters needed shorter time (24.4–26.4%, all p skating skills in amateur competitive and recreational level skaters. Further studies are needed to evaluate the reproducibility of this skill test in different populations including elite inline skaters. Key points Study evaluated the reliability and construct validity of a newly developed inline skating skill test. Evaluated test is a first protocol designed to assess specific inline skating skill. Two groups of amateur skaters with different skating proficiency repeated the skill test in four separate occasions. The results suggest that evaluated test is reliable and valid to evaluate inline skating skill in amateur skaters. PMID:27803616

  4. Gearbox Reliability Collaborative Phase 3 Gearbox 3 Test Report

    Energy Technology Data Exchange (ETDEWEB)

    Keller, Jonathan [National Renewable Energy Lab. (NREL), Golden, CO (United States); Wallen, Robb [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2017-02-24

    Many gearboxes in wind turbines do not achieve their expected design life; they do, however, commonly meet or exceed the design criteria specified in current standards in the gear, bearing, and wind turbine industry as well as third-party certification criteria. The cost of gearbox replacements and rebuilds, as well as the downtime associated with these failures, increases the cost of wind energy. In 2007, the U.S. Department of Energy established the National Renewable Energy Laboratory (NREL) Gearbox Reliability Collaborative (GRC). Its goals are to understand the root causes of premature gearbox failures and to improve their reliability. The GRC is examining a hypothesis that the gap between design-estimated and actual wind turbine gearbox reliability is caused by underestimation of loads, inaccurate design tools, the absence of critical elements in the design process, or insufficient testing. This report describes the recently completed tests of GRC Gearbox 3 in the National Wind Technology Center dynamometer and documents any modifications to the original test plan. In this manner, it serves as a guide for interpreting the publicly released data sets with brief analyses to illustrate the data. The primary test objective was to measure the planetary load-sharing characteristics in the same conditions as the original GRC gearbox design. If the measured load-sharing characteristics are close to the design model, the projected improvement in planetary section fatigue life and the efficacy of preloaded TRBs in mitigating the planetary bearing fatigue failure mode will have been demonstrated. Detailed analysis of that test objective will be presented in subsequent publications.

  5. Reasoning with Inductive Argument Test: A Study of Validity and Reliability

    Directory of Open Access Journals (Sweden)

    Mehmet Emrah Karadere

    2013-12-01

    Conclusion: The preliminary data obtained from the study of reliability and validity of the scale shows that ‘Reasoning with Inductive Argument Test’ supports reliability and validity in Turkish population. [JCBPR 2013; 2(3.000: 156-161

  6. Assessing high reliability via Bayesian approach and accelerated tests

    International Nuclear Information System (INIS)

    Erto, Pasquale; Giorgio, Massimiliano

    2002-01-01

    Sometimes the assessment of very high reliability levels is difficult for the following main reasons: - the high reliability level of each item makes it impossible to obtain, in a reasonably short time, a sufficient number of failures; - the high cost of the high reliability items to submit to life tests makes it unfeasible to collect enough data for 'classical' statistical analyses. In the above context, this paper presents a Bayesian solution to the problem of estimation of the parameters of the Weibull-inverse power law model, on the basis of a limited number (say six) of life tests, carried out at different stress levels, all higher than the normal one. The over-stressed (i.e. accelerated) tests allow the use of experimental data obtained in a reasonably short time. The Bayesian approach enables one to reduce the required number of failures adding to the failure information the available a priori engineers' knowledge. This engineers' involvement conforms to the most advanced management policy that aims at involving everyone's commitment in order to obtain total quality. A Monte Carlo study of the non-asymptotic properties of the proposed estimators and a comparison with the properties of maximum likelihood estimators closes the work

  7. Reliability and validity of the revised Gibson Test of Cognitive Skills, a computer-based test battery for assessing cognition across the lifespan

    Directory of Open Access Journals (Sweden)

    Moore AL

    2018-02-01

    Full Text Available Amy Lawson Moore, Terissa M Miller Gibson Institute of Cognitive Research, Colorado Springs, CO, USA Purpose: The purpose of the current study is to evaluate the validity and reliability of the revised Gibson Test of Cognitive Skills, a computer-based battery of tests measuring short-term memory, long-term memory, processing speed, logic and reasoning, visual processing, as well as auditory processing and word attack skills.Methods: This study included 2,737 participants aged 5–85 years. A series of studies was conducted to examine the validity and reliability using the test performance of the entire norming group and several subgroups. The evaluation of the technical properties of the test battery included content validation by subject matter experts, item analysis and coefficient alpha, test–retest reliability, split-half reliability, and analysis of concurrent validity with the Woodcock Johnson III Tests of Cognitive Abilities and Tests of Achievement.Results: Results indicated strong sources of evidence of validity and reliability for the test, including internal consistency reliability coefficients ranging from 0.87 to 0.98, test–retest reliability coefficients ranging from 0.69 to 0.91, split-half reliability coefficients ranging from 0.87 to 0.91, and concurrent validity coefficients ranging from 0.53 to 0.93.Conclusion: The Gibson Test of Cognitive Skills-2 is a reliable and valid tool for assessing cognition in the general population across the lifespan. Keywords: testing, cognitive skills, memory, processing speed, visual processing, auditory processing

  8. The Test-Retest Reliability of New Generation Power Indices of Wingate All-Out Test

    Directory of Open Access Journals (Sweden)

    Ozgur Ozkaya

    2018-04-01

    Full Text Available Although reliability correlations of traditional power indices of the Wingate test have been well documented, no study has analyzed new generation power indices based on milliseconds obtained from a Peak Bike. The purpose of this study was to investigate the retest reliability of new generation power indices. Thirty-two well-trained male athletes who were specialized in basketball, football, tennis, or track and field volunteered to take part in the study (age: 24.3 ± 2.2 years; body mass: 77 ± 8.3 kg; height: 180.3 ± 6.3 cm. Participants performed two Wingate all-out sessions on two separate days. Intra-class correlation coefficient (ICC, standard error measurement (SEM, smallest real differences (SRD and coefficient of variation (CV scores were analyzed based on the test and retest data. Reliability results of traditional power indices calculated based on 5-s means such as peak power, average power, power drop, and fatigue index ratio were similar with the previous findings in literature (ICC ≥ 0.94; CV ≤ 2.8%; SEM ≤ 12.28; SRD% ≤ 7.7%. New generation power indices such as peak power, average power, lowest power, power drop, fatigue index, power decline, maximum speed as rpm, and amount of total energy expenditure demonstrated high reliability (ICC ≥ 0.94; CV ≤ 4.3%; SEM ≤ 10.36; SRD% ≤ 8.8%. Time to peak power, time at maximum speed, and power at maximum speed showed a moderate level of reliability (ICC ≥ 0.73; CV ≤ 8.9%; SEM ≤ 63.01; SRD% ≤ 22.4%. The results of this study indicate that reliability correlations and SRD% of new generation power and fatigue-related indices are similar with traditional 5-s means. However, new time-related indices are very sensitive and moderately reliable.

  9. We need more replication research - A case for test-retest reliability.

    Science.gov (United States)

    Leppink, Jimmie; Pérez-Fuster, Patricia

    2017-06-01

    Following debates in psychology on the importance of replication research, we have also started to see pleas for a more prominent role for replication research in medical education. To enable replication research, it is of paramount importance to carefully study the reliability of the instruments we use. Cronbach's alpha has been the most widely used estimator of reliability in the field of medical education, notably as some kind of quality label of test or questionnaire scores based on multiple items or of the reliability of assessment across exam stations. However, as this narrative review outlines, Cronbach's alpha or alternative reliability statistics may complement but not replace psychometric methods such as factor analysis. Moreover, multiple-item measurements should be preferred above single-item measurements, and when using single-item measurements, coefficients as Cronbach's alpha should not be interpreted as indicators of the reliability of a single item when that item is administered after fundamentally different activities, such as learning tasks that differ in content. Finally, if we want to follow up on recent pleas for more replication research, we have to start studying the test-retest reliability of the instruments we use.

  10. Reliability Evaluation of Concentric Butterfly Valve Using Statistical Hypothesis Test

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Mu Seong; Choi, Jong Sik; Choi, Byung Oh; Kim, Do Sik [Korea Institute of Machinery and Materials, Daejeon (Korea, Republic of)

    2015-12-15

    A butterfly valve is a type of flow-control device typically used to regulate a fluid flow. This paper presents an estimation of the shape parameter of the Weibull distribution, characteristic life, and B10 life for a concentric butterfly valve based on a statistical analysis of the reliability test data taken before and after the valve improvement. The difference in the shape and scale parameters between the existing and improved valves is reviewed using a statistical hypothesis test. The test results indicate that the shape parameter of the improved valve is similar to that of the existing valve, and that the scale parameter of the improved valve is found to have increased. These analysis results are particularly useful for a reliability qualification test and the determination of the service life cycles.

  11. Reliability Evaluation of Concentric Butterfly Valve Using Statistical Hypothesis Test

    International Nuclear Information System (INIS)

    Chang, Mu Seong; Choi, Jong Sik; Choi, Byung Oh; Kim, Do Sik

    2015-01-01

    A butterfly valve is a type of flow-control device typically used to regulate a fluid flow. This paper presents an estimation of the shape parameter of the Weibull distribution, characteristic life, and B10 life for a concentric butterfly valve based on a statistical analysis of the reliability test data taken before and after the valve improvement. The difference in the shape and scale parameters between the existing and improved valves is reviewed using a statistical hypothesis test. The test results indicate that the shape parameter of the improved valve is similar to that of the existing valve, and that the scale parameter of the improved valve is found to have increased. These analysis results are particularly useful for a reliability qualification test and the determination of the service life cycles

  12. Test-Retest Reliability of Measures Commonly Used to Measure Striatal Dysfunction across Multiple Testing Sessions: A Longitudinal Study.

    Science.gov (United States)

    Palmer, Clare E; Langbehn, Douglas; Tabrizi, Sarah J; Papoutsi, Marina

    2017-01-01

    Cognitive impairment is common amongst many neurodegenerative movement disorders such as Huntington's disease (HD) and Parkinson's disease (PD) across multiple domains. There are many tasks available to assess different aspects of this dysfunction, however, it is imperative that these show high test-retest reliability if they are to be used to track disease progression or response to treatment in patient populations. Moreover, in order to ensure effects of practice across testing sessions are not misconstrued as clinical improvement in clinical trials, tasks which are particularly vulnerable to practice effects need to be highlighted. In this study we evaluated test-retest reliability in mean performance across three testing sessions of four tasks that are commonly used to measure cognitive dysfunction associated with striatal impairment: a combined Simon Stop-Signal Task; a modified emotion recognition task; a circle tracing task; and the trail making task. Practice effects were seen between sessions 1 and 2 across all tasks for the majority of dependent variables, particularly reaction time variables; some, but not all, diminished in the third session. Good test-retest reliability across all sessions was seen for the emotion recognition, circle tracing, and trail making test. The Simon interference effect and stop-signal reaction time (SSRT) from the combined-Simon-Stop-Signal task showed moderate test-retest reliability, however, the combined SSRT interference effect showed poor test-retest reliability. Our results emphasize the need to use control groups when tracking clinical progression or use pre-baseline training on tasks susceptible to practice effects.

  13. New method of thermal cycling stability test of phase change material

    Directory of Open Access Journals (Sweden)

    Putra Nandy

    2017-01-01

    Full Text Available Phase Change Material (PCM is the most promising material as thermal energy storage nowadays. As thermal energy storage, examination on endurance of material for long-term use is necessary to be carried out. Therefore, thermal cycling test is performed to ensure thermal stability of PCM. This study have found a new method on thermal cycling test of PCM sample by using thermoelectric as heating and cooling element. RT 22 HC was used as PCM sample on this thermal cycling test. The new method had many advantages compared to some references of the same test. It just needed a small container for PCM sample. The thermoelectric could release heat to PCM sample and absorb heat from PCM sample uniformly, respectively, was called as heating and cooling process. Hence, thermoelectric had to be supported by a relay control device to change its polarity so it could heat and cool PCM sample alternately and automatically. On the other hand, the thermoelectric was cheap, easy to be found and available in markets. It can be concluded that new method of thermal cycling test by using thermoelectric as source of heating and cooling can be a new reference for performing thermal cycling test on PCM.

  14. "Graded Cycling Test with Talk Test" Is a Reliable Test to Monitor Cardiovascular Fitness in Patients with Minor Stroke

    DEFF Research Database (Denmark)

    Steen Krawcyk, Rikke; Vinther, Anders; Caesar Petersen, Nicolas

    2017-01-01

    variability may challenge currently used cardiovascular monitoring. The Graded Cycling Test with Talk Test is a submaximal exercise test independent of heart rate variability, shown reliable for patients with cardiac disease. METHODS: Patients diagnosed with lacunar stroke according to TOAST (Trial of Org...... a minor measurement error: 12.9 W for groups of patients (standard error of measurement, SEM95) and 18.3 W for individual patients (smallest real difference). CONCLUSION: The "Graded Cycling Test with Talk Test" is feasible and reliable for monitoring exercise effects in patients with lacunar stroke...... 10172 in Acute Stroke Treatment) criteria performed an incremental exercise test on a stationary bicycle with a 15 W (watt) increase in workload every minute. Toward the end of each incremental step, the patients recited a standardized text passage and subsequently were asked: "Are you still able...

  15. Thermal cycling fatigue of organic thermal interface materials using a thermal-displacement measurement technique

    Science.gov (United States)

    Steill, Jason Scott

    The long term reliability of polymer-based thermal interface materials (TIM) is essential for modern electronic packages which require robust thermal management. The challenge for today's materials scientists and engineers is to maximize the heat flow from integrated circuits through a TIM and out the heat sink. Thermal cycling of the electronic package and non-uniformity in the heat flux with respect to the plan area can lead to void formation and delamination which re-introduces inefficient heat transfer. Measurement and understanding at the nano-scale is essential for TIM development. Finding and documenting the evolution of the defects is dependent upon a full understanding of the thermal probes response to changing environmental conditions and the effects of probe usage. The response of the thermal-displacement measurement technique was dominated by changes to the environment. Accurate measurement of the thermal performance was hindered by the inability to create a model system and control the operating conditions. This research highlights the need for continued study into the probe's thermal and mechanical response using tightly controlled test conditions.

  16. Large test rigs verify Clinch River control rod reliability

    International Nuclear Information System (INIS)

    Michael, H.D.; Smith, G.G.

    1983-01-01

    The purpose of the Clinch River control test programme was to use multiple full-scale prototypic control rod systems for verifying the system's ability to perform reliably during simulated reactor power control and emergency shutdown operations. Two major facilities, the Shutdown Control Rod and Maintenance (Scram) facility and the Dynamic and Seismic Test (Dast) facility, were constructed. The test programme of each facility is described. (UK)

  17. Test your memory-Turkish version (TYM-TR): reliability and validity study of a cognitive screening test.

    Science.gov (United States)

    Maviş, Ilknur; Özbabalik Adapinar, Belgin Demet; Yenilmez, Çinar; Aydin, Ayşe; Olgun, Engin; Bal, Cengiz

    2015-01-01

    The test your memory (TYM) is reported to be a sensitive cognitive function assessment scale for people with dementia. The aim of the present study was to investigate the reliability and validity of an adapted Turkish version of the TYM (TYM-TR) among Turkish dementia patients. The TYM-TR was given to 59 patients with dementia aged 60+ and 336 normal controls aged 23-75+. The diagnostic utility of the TYM-TR was compared with that of the mini-mental state examination (MMSE) to validate it. The internal consistency of the TYM-TR was a = 0.85. The test-retest reliability was 0.97 (P reliability and validity to distinguish dementia in the Turkish population.

  18. Reliability Testing Using the Vehicle Durability Simulator

    Science.gov (United States)

    2017-11-20

    techniques are employed to reduce test and simulation time. Through application of these processes and techniques the reliability characteristics...remote parameter control (RPC) software. The software is specifically designed for the data collection, analysis, and simulation processes outlined in...the selection process for determining the desired runs for simulation . 4.3 Drive File Development. After the data have been reviewed and

  19. Absolute and Relative Reliability of the Timed 'Up & Go' Test and '30second Chair-Stand' Test in Hospitalised Patients with Stroke

    DEFF Research Database (Denmark)

    Lyders Johansen, Katrine; Derby Stistrup, Rikke; Skibdal Schjøtt, Camilla

    2016-01-01

    OBJECTIVE: The timed 'Up & Go' test and '30second Chair-Stand' test are simple clinical outcome measures widely used to assess functional performance. The reliability of both tests in hospitalised stroke patients is unknown. The purpose was to investigate the relative and absolute reliability...... of both tests in patients admitted to an acute stroke unit. METHODS: Sixty-two patients (men, n = 41) attended two test sessions separated by a one hours rest. Intraclass correlation coefficients (ICC2,1) were calculated to assess relative reliability. Absolute reliability was expressed as Standard Error...... of Measurement (with 95% certainty-SEM95) and Smallest Real Difference (SRD) and as percentage of their respective means if heteroscedasticity was observed in Bland Altman plots (SEM95% and SRD%). RESULTS: ICC values for interrater reliability were 0.97 and 0.99 for the timed 'Up & Go' test and 0.88 and 0...

  20. Vertical jumping tests in volleyball: reliability, validity, and playing-position specifics.

    Science.gov (United States)

    Sattler, Tine; Sekulic, Damir; Hadzic, Vedran; Uljevic, Ognjen; Dervisevic, Edvin

    2012-06-01

    Vertical jumping is known to be important in volleyball, and jumping performance tests are frequently studied for their reliability and validity. However, most studies concerning jumping in volleyball have dealt with standard rather than sport-specific jumping procedures and tests. The aims of this study, therefore, were (a) to determine the reliability and factorial validity of 2 volleyball-specific jumping tests, the block jump (BJ) test and the attack jump (AJ) test, relative to 2 frequently used and systematically validated jumping tests, the countermovement jump test and the squat jump test and (b) to establish volleyball position-specific differences in the jumping tests and simple anthropometric indices (body height [BH], body weight, and body mass index [BMI]). The BJ was performed from a defensive volleyball position, with the hands positioned in front of the chest. During an AJ, the players used a 2- to 3-step approach and performed a drop jump with an arm swing followed by a quick vertical jump. A total of 95 high-level volleyball players (all men) participated in this study. The reliability of the jumping tests ranged from 0.97 to 0.99 for Cronbach's alpha coefficients, from 0.93 to 0.97 for interitem correlation coefficients and from 2.1 to 2.8 for coefficients of variation. The highest reliability was found for the specific jumping tests. The factor analysis extracted one significant component, and all of the tests were highly intercorrelated. The analysis of variance with post hoc analysis showed significant differences between 5 playing positions in some of the jumping tests. In general, receivers had a greater jumping capacity, followed by libero players. The differences in jumping capacities should be emphasized vis-a-vis differences in the anthropometric measures of players, where middle hitters had higher BH and body weight, followed by opposite hitters and receivers, with no differences in the BMI between positions.

  1. Thermal conductivity tests on buffermasses of bentonite/silt

    International Nuclear Information System (INIS)

    Knutsson, S.

    1977-09-01

    The investigation concerns the thermal conductivity of the bentonite/quartz buffer mass suggested as embedding substance for radioactive canisters. The first part presents the theoretical relationships associated with the various heat transfer mechanisms in moist granular materials. Chapter 3 describes the author's experimental determination of the thermal conductivity of the buffer mass. The tested mass consisted of 10 percent (by weight) bentonite and 90 percent natural silt. Four tests were made with different water content values and degree of water saturation. A comparison between the measured and calculated thermal conductivities is given. It is shown that the conductivity can be calculated with an accuracy of +-20 percent. (author)

  2. Thermal-hydraulic tests with out-of-pile test facility for BOCA development

    International Nuclear Information System (INIS)

    Kitagishi, Shigeru; Aoyama, Masashi; Tobita, Masahiro; Inaba, Yoshitomo; Yamaura, Takayuki

    2012-01-01

    The fuel transient test facility was prepared for power ramping tests of light-water-reactor (LWR) fuels in the Japan Materials Testing Reactor (JMTR) under a contract project with the Nuclear Industrial Safety Agent (NISA) of the Ministry of Economy, Trade and Industry (METI). It is necessary to develop high accuracy analysis procedure for power ramping tests after restart of the JMTR. The out-of-pile test facility to simulate thermal-hydraulic conditions of the fuel transient test facility was therefore developed. Applicability of the analysis code ACE-3D was examined for thermal-hydraulic analysis of power ramping tests for 10x10 BWR fuels by the fuel transient test facility. As the results, the calculated temperature was 304°C in comparison with measured value of 304.9-317.4°C in the condition of 600 W/cm. There is a bright prospect of high accuracy power ramping tests by the fuel transient test facility in JMTR. (author)

  3. Final report : testing and evaluation for solar hot water reliability.

    Energy Technology Data Exchange (ETDEWEB)

    Caudell, Thomas P. (University of New Mexico, Albuquerque, NM); He, Hongbo (University of New Mexico, Albuquerque, NM); Menicucci, David F. (Building Specialists, Inc., Albuquerque, NM); Mammoli, Andrea A. (University of New Mexico, Albuquerque, NM); Burch, Jay (National Renewable Energy Laboratory, Golden CO)

    2011-07-01

    Solar hot water (SHW) systems are being installed by the thousands. Tax credits and utility rebate programs are spurring this burgeoning market. However, the reliability of these systems is virtually unknown. Recent work by Sandia National Laboratories (SNL) has shown that few data exist to quantify the mean time to failure of these systems. However, there is keen interest in developing new techniques to measure SHW reliability, particularly among utilities that use ratepayer money to pay the rebates. This document reports on an effort to develop and test new, simplified techniques to directly measure the state of health of fielded SHW systems. One approach was developed by the National Renewable Energy Laboratory (NREL) and is based on the idea that the performance of the solar storage tank can reliably indicate the operational status of the SHW systems. Another approach, developed by the University of New Mexico (UNM), uses adaptive resonance theory, a type of neural network, to detect and predict failures. This method uses the same sensors that are normally used to control the SHW system. The NREL method uses two additional temperature sensors on the solar tank. The theories, development, application, and testing of both methods are described in the report. Testing was performed on the SHW Reliability Testbed at UNM, a highly instrumented SHW system developed jointly by SNL and UNM. The two methods were tested against a number of simulated failures. The results show that both methods show promise for inclusion in conventional SHW controllers, giving them advanced capability in detecting and predicting component failures.

  4. Reliability of the Timed Up and Go test and Ten-Metre Timed Walk Test in Pregnant Women with Pelvic Girdle Pain.

    Science.gov (United States)

    Evensen, Natalie M; Kvåle, Alice; Braekken, Ingeborg H

    2015-09-01

    There is a lack of functional objective tests available to measure functional status in women with pelvic girdle pain (PGP). The purpose of this study was to establish test-retest and intertester reliability of the Timed Up and Go (TUG) test and Ten-metre Timed Walk Test (10mTWT) in pregnant women with PGP. A convenience sample of women was recruited over a 4-month period and tested on two occasions, 1 week apart to determine test-retest reliability. Intertester reliability was established between two assessors at the first testing session. Subjects were instructed to undertake the TUG and 10mTWT at maximum speed. One practise trial and two timed trials for each walking test was undertaken on Day 1 and one practise trial and one timed trial on Day 2. Seventeen women with PGP aged 31.1 years (SD [standard deviation] = 2.3) and 28.7 weeks pregnant (SD = 7.4) completed gait testing. Test-retest reliability using the intraclass correlation coefficient (ICC) was excellent for the TUG (0.88) and good for the 10mTWT (0.74). Intertester reliability was determined in the first 13 participants with excellent ICC values being found for both walking tests (TUG: 0.95; 10mTWT: 0.94). This study demonstrated that the TUG and 10mTWT undertaken at fast pace are reliable, objective functional tests in pregnant women with PGP. While both tests are suitable for use in the clinical and research settings, we would recommend the TUG given the findings of higher test-retest reliability and as this test requires less space and time to set up and score. Future studies in a larger sample size are warranted to confirm the results of this study. Copyright © 2015 John Wiley & Sons, Ltd.

  5. Reliability of CGA/LGA/HDI Package Board/Assembly (Final Report)

    Science.gov (United States)

    Ghaffaroam. Reza

    2014-01-01

    Package manufacturers are now offering commercial-off-the-shelf column grid array (COTS CGA) packaging technologies in high-reliability versions. Understanding the process and quality assurance (QA) indicators for reliability are important for low-risk insertion of these advanced electronics packages. The previous reports, released in January of 2012 and January of 2013, presented package test data, assembly information, and reliability evaluation by thermal cycling for CGA packages with 1752, 1517, 1509, and 1272 inputs/outputs (I/Os) and 1-mm pitch. It presented the thermal cycling (-55C either 100C or 125C) test results for up to 200 cycles. This report presents up to 500 thermal cycles with quality assurance and failure analysis evaluation represented by optical photomicrographs, 2D real time X-ray images, dye-and-pry photomicrographs, and optical/scanning electron Microscopy (SEM) cross-sectional images. The report also presents assembly challenge using reflowing by either vapor phase or rework station of CGA and land grid array (LGA) versions of three high I/O packages both ceramic and plastic configuration. A new test vehicle was designed having high density interconnect (HDI) printed circuit board (PCB) with microvia-in-pad to accommodate both LGA packages as well as a large number of fine pitch ball grid arrays (BGAs). The LGAs either were assembled onto HDI PCB as an LGA or were solder paste print and reflow first to form solder dome on pads before assembly. Both plastic BGAs with 1156 I/O and ceramic LGAs were assembled. It also presented the X-ray inspection results as well as failures due to 200 thermal cycles. Lessons learned on assembly of ceramic LGAs are also presented.

  6. Reliability and feasibility of the six minute walk test in subjects with myotonic dystrophy.

    Science.gov (United States)

    Kierkegaard, Marie; Tollbäck, Anna

    2007-12-01

    The objective was to describe test-retest reliability and feasibility of the six minute walk test in adult subjects with myotonic dystrophy type 1. Twelve subjects (28-68 years, mean 44) performed three six minute walk tests on two occasions, one week apart. Relative reliability was high (ICC(2.1)=0.99) and absolute reliability values were low (standard error of measurement 12 m, repeatability 33 m). Feasibility was investigated in a sample of 64 subjects (19-70 years, mean 43). Fifty-two subjects were able to perform two tests on the same day. Subjects with severe proximal weakness had difficulties performing repeated tests. A practice trial followed by a second test on the same day can be recommended for most subjects, and the best test should be used for evaluations. In conclusion, even though the study sample was small, the present study indicates that the six minute walk test is reliable and feasible in subjects with myotonic dystrophy type 1.

  7. In-Situ Testing of the Thermal Diffusivity of Polysilicon Thin Films

    Directory of Open Access Journals (Sweden)

    Yi-Fan Gu

    2016-10-01

    Full Text Available This paper presents an intuitive yet effective in-situ thermal diffusivity testing structure and testing method. The structure consists of two doubly clamped beams with the same width and thickness but different lengths. When the electric current is applied through two terminals of one beam, the beam serves as thermal resistor and the resistance R(t varies as temperature rises. A delicate thermodynamic model considering thermal convection, thermal radiation, and film-to-substrate heat conduction was established for the testing structure. The presented in-situ thermal diffusivity testing structure can be fabricated by various commonly used micro electro mechanical systems (MEMS fabrication methods, i.e., it requires no extra customized processes yet provides electrical input and output interfaces for in-situ testing. Meanwhile, the testing environment and equipment had no stringent restriction, measurements were carried out at normal temperatures and pressures, and the results are relatively accurate.

  8. Proving Test on the Reliability for Reactor Containment Vessel

    International Nuclear Information System (INIS)

    Takumi, K.; Nonaka, A.

    1988-01-01

    NUPEC (Nuclear Power Engineering Test Center) has started an eight-year project of Proving Test on the Reliability for Reactor Containment Vessel since June 1987. The objective of this project is to confirm the integrity of containment vessels under severe accident conditions. This paper shows the outline of this project. The test Items are (1) Hydrogen mixing and distribution test, (2) Hydrogen burning test, (3) Iodine trapping characteristics test, and (4) Structural behavior test. Based on the test results, computer codes are verified and as the results of analysis and evaluation by the computer codes, containment integrity is to be confirmed

  9. Research Note The reliability of a field test kit for the detection and ...

    African Journals Online (AJOL)

    Research Note The reliability of a field test kit for the detection and the persistence of ... Open Access DOWNLOAD FULL TEXT ... The objectives were to test a field kit for practicality and reliability, to assess the spread of the bacteria among ...

  10. Test-retest reliability and practice effects of the Wechsler Memory Scale-III.

    Science.gov (United States)

    Lo, Ada H Y; Humphreys, Michael; Byrne, Gerard J; Pachana, Nancy A

    2012-09-01

    Although serial administration of cognitive tests is increasingly common, there is a paucity of research on test-retest reliabilities and practice effects, both of which are important for evaluating changes in functioning. Reliability is generally conceptualized as involving short-lasting changes in performance. However, when repeated testing occurs over a period of years, there will be some longer lasting effects. The implications of these longer lasting effects and practice effects on reliability were examined in the context of repeated administrations of the Wechsler Memory Scale-III in 339 community-dwelling women aged 40-79 years over 2 to 7 years. The results showed that Logical Memory and Verbal Paired Associates subtests were consistently the most reliable subtests across the age cohorts. The magnitude of practice effects varied as a function of subtests and age. The largest practice effects were found in the youngest age cohort, especially on the Faces, Logical Memory, and Verbal Paired Associates subtests. ©2012 The British Psychological Society.

  11. Solar panel thermal cycling testing by solar simulation and infrared radiation methods

    Science.gov (United States)

    Nuss, H. E.

    1980-01-01

    For the solar panels of the European Space Agency (ESA) satellites OTS/MAROTS and ECS/MARECS the thermal cycling tests were performed by using solar simulation methods. The performance data of two different solar simulators used and the thermal test results are described. The solar simulation thermal cycling tests for the ECS/MARECS solar panels were carried out with the aid of a rotatable multipanel test rig by which simultaneous testing of three solar panels was possible. As an alternative thermal test method, the capability of an infrared radiation method was studied and infrared simulation tests for the ultralight panel and the INTELSAT 5 solar panels were performed. The setup and the characteristics of the infrared radiation unit using a quartz lamp array of approx. 15 sq and LN2-cooled shutter and the thermal test results are presented. The irradiation uniformity, the solar panel temperature distribution, temperature changing rates for both test methods are compared. Results indicate the infrared simulation is an effective solar panel thermal testing method.

  12. Thermal-hydraulic tests for reactor safety system

    International Nuclear Information System (INIS)

    Chun, Se Young; Chung, Moon Ki; Baek, Won Pil

    2002-05-01

    Tests for the safety depressurization system, Sparger adopted for the Korean next generation reactor, APR1400 are carried out for several geometries with the B and C (Blowdown and Condensation) facility in the condition of high temperature and pressure and with a small test facility in the condition of atmospheric temperature and pressure. Tests for the critical heat flux are performed with the RCS(Reactor Coolant System) facility as well as with the Freon CHF Loop in the condition of high temperature and pressure. The atmospheric temperature and pressure facility is utilized for development of the high standard thermal hydraulic measurement technology. The optical method is developed to measure the local thermal-hydraulic behavior for the single and two-phase boiling phenomena

  13. Reliability of a New Lower-Extremity Motor Coordination Test

    Directory of Open Access Journals (Sweden)

    Antosiak-Cyrak Katarzyna

    2015-12-01

    Full Text Available Introduction. Motor coordination is a basic motor ability necessary for daily life, which also allows athletes to win a sports rivalry and patients to assess their recovery progress after therapy and rehabilitation. The aim of the present study was to assess the reliability of a new lower-extremity rate of movements test and testing apparatus.

  14. Numerical model for the thermal yield estimation of unglazed photovoltaic-thermal collectors using indoor solar simulator testing

    NARCIS (Netherlands)

    Katiyar, M.; van Balkom, M.W.; Rindt, C.C.M.; de Keizer, C.; Zondag, H.A.

    2017-01-01

    It is a common practice to test solar thermal and photovoltaic-thermal (PVT) collectors outdoors. This requires testing over several weeks to account for different weather conditions encountered throughout the year, which is costly and time consuming. The outcome of these tests is an estimation of

  15. Standardization, Validity and Reliability Study of Gülhane Aphasia Test-2 (GAT-2

    Directory of Open Access Journals (Sweden)

    İlknur Maviş

    2007-04-01

    Full Text Available OBJECTIVE: Gülhane Aphasia Test-2 (GAT-2 has been developed to show the presence of a language disorder ‘aphasia’ and to give the clinician implications for the accompanying speech disorders such as apraxia and dysarthria. OBJECTIVE: The aim of the study was to report standardization, validity and reliability study of GAT-2. METHODS: : 10 healthy individuals were tested initially for the pilot study. 134 healthy individual was included to the standardization study and 30 individuals with aphasia and 11 individuals with right brain injury was included to the validation study. The inter group GAT-2 score differentiations and the effects of age, years of education, sex variances were observed. GAT-2 cut-off scores were calculated by the scores of healthy individuals. GAT-2 test-retest reliability and inter-observer reliability was calculated. RESULTS: Healthy individuals’ GAT-2 scores were significantly different from the GAT-2 scores of aphasic patients, but not from right brain injured patients’. Healthy individuals’ GAT-2 scores were not affected from the sex, age variances but from years of education, so cut-off scores were calculated by this variance. GAT-2 scores of aphasic patients were not affected from age, sex and years of education. Test-retest and inter-observer reliability and internal consistency results showed that GAT-2 is a highly reliable aphasia screening test. CONCLUSION: GAT-2 was found to be a standardized, highly reliable and a valid aphasia test for Turkish stroke patients with aphasia

  16. Reliability of ultrasound thickness measurement of the abdominal muscles during clinical isometric endurance tests.

    Science.gov (United States)

    ShahAli, Shabnam; Arab, Amir Massoud; Talebian, Saeed; Ebrahimi, Esmaeil; Bahmani, Andia; Karimi, Noureddin; Nabavi, Hoda

    2015-07-01

    The study was designed to evaluate the intra-examiner reliability of ultrasound (US) thickness measurement of abdominal muscles activity when supine lying and during two isometric endurance tests in subjects with and without Low back pain (LBP). A total of 19 women (9 with LBP, 10 without LBP) participated in the study. Within-day reliability of the US thickness measurements at supine lying and the two isometric endurance tests were assessed in all subjects. The intra-class correlation coefficient (ICC) was used to assess the relative reliability of thickness measurement. The standard error of measurement (SEM), minimal detectable change (MDC) and the coefficient of variation (CV) were used to evaluate the absolute reliability. Results indicated high ICC scores (0.73-0.99) and also small SEM and MDC scores for within-day reliability assessment. The Bland-Altman plots of agreement in US measurement of the abdominal muscles during the two isometric endurance tests demonstrated that 95% of the observations fall between the limits of agreement for test and retest measurements. Together the results indicate high intra-tester reliability for the US measurement of the thickness of abdominal muscles in all the positions tested. According to the study's findings, US imaging can be used as a reliable method for assessment of abdominal muscles activity in supine lying and the two isometric endurance tests employed, in participants with and without LBP. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Data mining-based coefficient of influence factors optimization of test paper reliability

    Science.gov (United States)

    Xu, Peiyao; Jiang, Huiping; Wei, Jieyao

    2018-05-01

    Test is a significant part of the teaching process. It demonstrates the final outcome of school teaching through teachers' teaching level and students' scores. The analysis of test paper is a complex operation that has the characteristics of non-linear relation in the length of the paper, time duration and the degree of difficulty. It is therefore difficult to optimize the coefficient of influence factors under different conditions in order to get text papers with clearly higher reliability with general methods [1]. With data mining techniques like Support Vector Regression (SVR) and Genetic Algorithm (GA), we can model the test paper analysis and optimize the coefficient of impact factors for higher reliability. It's easy to find that the combination of SVR and GA can get an effective advance in reliability from the test results. The optimal coefficient of influence factors optimization has a practicability in actual application, and the whole optimizing operation can offer model basis for test paper analysis.

  18. The validity and reliability of a dynamic neuromuscular stabilization-heel sliding test for core stability.

    Science.gov (United States)

    Cha, Young Joo; Lee, Jae Jin; Kim, Do Hyun; You, Joshua Sung H

    2017-10-23

    Core stabilization plays an important role in the regulation of postural stability. To overcome shortcomings associated with pain and severe core instability during conventional core stabilization tests, we recently developed the dynamic neuromuscular stabilization-based heel sliding (DNS-HS) test. The purpose of this study was to establish the criterion validity and test-retest reliability of the novel DNS-HS test. Twenty young adults with core instability completed both the bilateral straight leg lowering test (BSLLT) and DNS-HS test for the criterion validity study and repeated the DNS-HS test for the test-retest reliability study. Criterion validity was determined by comparing hip joint angle data that were obtained from BSLLT and DNS-HS measures. The test-retest reliability was determined by comparing hip joint angle data. Criterion validity was (ICC2,3) = 0.700 (preliability was (ICC3,3) = 0.953 (pvalidity data demonstrated a good relationship between the gold standard BSLLT and DNS-HS core stability measures. Test-retest reliability data suggests that DNS-HS core stability was a reliable test for core stability. Clinically, the DNS-HS test is useful to objectively quantify core instability and allow early detection and evaluation.

  19. Assessment of Advanced Life Support competence when combining different test methods--reliability and validity

    DEFF Research Database (Denmark)

    Ringsted, C; Lippert, F; Hesselfeldt, R

    2007-01-01

    Cardiac Arrest Simulation Test (CASTest) scenarios for the assessments according to guidelines 2005. AIMS: To analyse the reliability and validity of the individual sub-tests provided by ERC and to find a combination of MCQ and CASTest that provides a reliable and valid single effect measure of ALS...... that possessed high reliability, equality of test sets, and ability to discriminate between the two groups of supposedly different ALS competence. CONCLUSIONS: ERC sub-tests of ALS competence possess sufficient reliability and validity. A combined ALS score with equal weighting of one MCQ and one CASTest can...... competence. METHODS: Two groups of participants were included in this randomised, controlled experimental study: a group of newly graduated doctors, who had not taken the ALS course (N=17) and a group of students, who had passed the ALS course 9 months before the study (N=16). Reliability in terms of inter...

  20. COMPARISON OF RESULTS OF THERMAL TESTS OF BALCONY DOORS

    Directory of Open Access Journals (Sweden)

    Golubev Stanislav Sergeevich

    2012-10-01

    Full Text Available Results of thermal tests of balcony doors are presented in the article. In the course of the research project, two types of doors were tested. The first type represents a PVC frame door (width 82 mm; it has a triple glazing (4K-16Ar-4-16Ar-K4; its blank part represents a polystyrene sandwich panel (width 40 mm. The second type represents a PVC frame door (width 82 mm, that has a triple glazing (4K-16Ar-4-16Ar-K4 and composite PVC panels. The testing procedure and processing results are described in the article. The test has demonstrated that the thermal resistance value of the balcony door of the first type exceeds the thermal resistance value of the balcony door of the second type.

  1. INTERSESSION RELIABILITY OF UPPER EXTREMITY ISOKINETIC PUSH-PULL TESTING.

    Science.gov (United States)

    Riemann, Bryan L; Davis, Sarah E; Huet, Kevin; Davies, George J

    2016-02-01

    Based on the frequency pushing and pulling patterns are used in functional activities, there is a need to establish an objective method of quantifying the muscle performance characteristics associated with these motions, particularly during the later stages of rehabilitation as criteria for discharge. While isokinetic assessment offers an approach to quantifying muscle performance, little is known about closed kinetic chain (CKC) isokinetic testing of the upper extremity (UE). To determine the intersession reliability of isokinetic upper extremity measurement of pushing and pulling peak force and average power at slow (0.24 m/s), medium (0.43 m/s) and fast (0.61 m/s) velocities in healthy young adults. The secondary purpose was to compare pushing and pulling peak force (PF) and average power (AP) between the upper extremity limbs (dominant, non-dominant) across the three velocities. Twenty-four physically active men and women completed a test-retest (>96 hours) protocol in order to establish isokinetic UE CKC reliability of PF and AP during five maximal push and pull repetitions at three velocities. Both limb and speed orders were randomized between subjects. High test-retest relative reliability using intraclass correlation coefficients (ICC2, 1) were revealed for PF (.91-.97) and AP (.85-.95) across velocities, limbs and directions. PF typical error (% coefficient of variation) ranged from 6.1% to 11.3% while AP ranged from 9.9% to 26.7%. PF decreased significantly (p pushing were significantly greater than pulling at all velocities, however the push-pull differences in PF became less as velocity increased. There were no significant differences identified between the dominant and nondominant limbs. Isokinetically derived UE CKC push-pull PF and AP are reliable measures. The lack of limb differences in healthy normal participants suggests that clinicians can consider bilateral comparisons when interpreting test performance. The increase in pushing PF and

  2. Thermal-environmental testing of a 30-cm engineering model thruster

    Science.gov (United States)

    Mirtich, M. J.

    1976-01-01

    An experimental test program was carried out to document all 30-cm electron bombardment Hg ion bombardment thruster functions and characteristics over the thermal environment of several proposed missions. An engineering model thruster was placed in a thermal test facility equipped with -196 C walls and solar simulation. The thruster was cold soaked and exposed to simulated eclipses lasting in duration from 17 to 72 minutes. The thruster was operated at quarter, to full beam power in various thermal configurations which simulated multiple thruster operation, and was also exposed to 1 and 2 suns solar simulation. Thruster control characteristics and constraints; performance, including thrust magnitude and direction; and structural integrity were evaluated over the range of thermal environments tested.

  3. FFTF [Fast Flux Test Facility] reactor shutdown system reliability reevaluation

    International Nuclear Information System (INIS)

    Pierce, B.F.

    1986-07-01

    The reliability analysis of the Fast Flux Test Facility reactor shutdown system was reevaluated. Failure information based on five years of plant operating experience was used to verify original reliability numbers or to establish new ones. Also, system modifications made subsequent to performance of the original analysis were incorporated into the reevaluation. Reliability calculations and sensitivity analyses were performed using a commercially available spreadsheet on a personal computer. The spreadsheet was configured so that future failures could be tracked and compared with expected failures. A number of recommendations resulted from the reevaluation including both increased and decreased surveillance intervals. All recommendations were based on meeting or exceeding existing reliability goals. Considerable cost savings will be incurred upon implementation of the recommendations

  4. A Thermal Test System for Helmet Cooling Studies

    Directory of Open Access Journals (Sweden)

    Shaun Fitzgerald

    2018-02-01

    Full Text Available One of the primary causes of discomfort to both irregular and elite cyclists is heat entrapment by a helmet resulting in overheating and excessive sweating of the head. To accurately assess the cooling effectiveness of bicycle helmets, a heated plastic thermal headform has been developed. The construction consists of a 3D-printed headform of low thermal conductivity with an internal layer of high thermal mass that is heated to a constant uniform temperature by an electrical heating element. Testing is conducted in a wind tunnel where the heater power remains constant and the resulting surface temperature distribution is directly measured by 36 K-type thermocouples embedded within the surface of the head in conjunction with a thermal imaging camera. Using this new test system, four bicycle helmets were studied in order to measure their cooling abilities and to identify ‘hot spots’ where cooling performance is poor.

  5. Long term test-retest reliability of Oswestry Disability Index in male office workers.

    Science.gov (United States)

    Irmak, Rafet; Baltaci, Gul; Ergun, Nevin

    2015-01-01

    The Oswestry Disability Index (ODI) is one of the most common condition specific outcome measures used in the management of spinal disorders. But there is insufficient study on healthy populations and long term test-retest reliability. This is important because healthy populations are often used for control groups in low back pain interventions, and knowing the reliability of the controls affects the interpretation of the findings of these studies. The purpose of this study is to determine the long term test-retest reliability of ODI in office workers. Participants who have no chronic low back pain history were included in study. Subjects were assessed by the Turkish-ODI 2.0 (e-forms) on 1st, 2nd, 4th, 8th, 15th, 30th days to determine the stability of ODI scores over time. The study began with 58 (12 female, 46 male) participants. 36 (3 female, 33 male) participated for the full 30 days. Kolmogorov-Smirnov and Friedman tests were used. Test-retest reliability was evaluated by using nonparametric statistics. All tests were done by using SPSS-11. There was no statistically significant difference among the median scores of each day. (χ= 6.482, p >  0.05). The difference between median score of the days with 1st day was neither statistically nor clinically significant. ODI has long term test re-test reliability in healthy subjects over a 1 month time interval.

  6. Thermal Environmental Testing of NSTAR Engineering Model Ion Thrusters

    Science.gov (United States)

    Rawlin, Vincent K.; Patterson, Michael J.; Becker, Raymond A.

    1999-01-01

    NASA's New Millenium program will fly a xenon ion propulsion system on the Deep Space 1 Mission. Tests were conducted under NASA's Solar Electric Propulsion Technology Applications Readiness (NSTAR) Program with 3 different engineering model ion thrusters to determine thruster thermal characteristics over the NSTAR operating range in a variety of thermal environments. A liquid nitrogen-cooled shroud was used to cold-soak the thruster to -120 C. Initial tests were performed prior to a mature spacecraft design. Those results and the final, severe, requirements mandated by the spacecraft led to several changes to the basic thermal design. These changes were incorporated into a final design and tested over a wide range of environmental conditions.

  7. Reliability, construct and discriminative validity of clinical testing in subjects with and without chronic neck pain

    DEFF Research Database (Denmark)

    Jørgensen, René; Ris Hansen, Inge; Falla, Deborah

    2014-01-01

    -retest reliability in people with and without chronic neck pain. Moreover, construct and between-group discriminative validity of the tests were examined. METHODS: Twenty-one participants with chronic neck pain and 21 asymptomatic participants were included. Intra- and inter-reliability were evaluated for the Cranio-Cervical...... Flexion Test (CCFT), Range of Movement (ROM), Joint Position Error (JPE), Gaze Stability (GS), Smooth Pursuit Neck Torsion Test (SPNTT), and neuromuscular control of the Deep Cervical Extensors (DCE). Test-retest reliability was assessed for Postural Control (SWAY) and Pressure Pain Threshold (PPT) over......BACKGROUND: The reliability of clinical tests for the cervical spine has not been adequately evaluated. Six cervical clinical tests, which are low cost and easy to perform in clinical settings, were tested for intra- and inter-examiner reliability, and two performance tests were assessed for test...

  8. Practice effects and test-re-test reliability of the Five Digit Test in patients with stroke over four serial assessments.

    Science.gov (United States)

    Chiu, En-Chi; Koh, Chia-Lin; Tsai, Chia-Yin; Lu, Wen-Shian; Sheu, Ching-Fan; Hsueh, I-Ping; Hsieh, Ching-Lin

    2014-01-01

    To investigate practice effect and test-re-test reliability of the Five Digit Test (FDT) over four serial assessments in patients with stroke. Single-group repeated measures design. Twenty-five patients with stroke were administered the FDT in four consecutive assessments every 2 weeks. The FDT contains four parts with five indices: 'basic measures of attention and processing speed', 'selective attention', 'alternating attention', 'ability of inhibition' and 'ability of switching'. The five indices of the FDT showed trivial-to-small practice effects (Cohen's d = 0.03-0.47) and moderate-to-excellent test-re-test reliability (intra-class correlation coefficient = 0.59-0.97). Practice effects of the five indices all appeared cumulative, but one index, 'basic measures of attention and processing speed', reached a plateau after the second assessment. The minimum and maximum values of the 90% confidence interval (CI) of reliable change index modified for practice (RCIp) for this index were [-17.6, 11.2]. One of five indices of the FDT reached a plateau, whose minimum and maximum values of the 90% CI RCIp are useful to determine whether the change in an individual's score is real. However, clinicians and researchers should be cautious when interpreting the test results of these four indices over repeated assessments.

  9. Reliability residual-life prediction method for thermal aging based on performance degradation

    International Nuclear Information System (INIS)

    Ren Shuhong; Xue Fei; Yu Weiwei; Ti Wenxin; Liu Xiaotian

    2013-01-01

    The paper makes the study of the nuclear power plant main pipeline. The residual-life of the main pipeline that failed due to thermal aging has been studied by the use of performance degradation theory and Bayesian updating methods. Firstly, the thermal aging impact property degradation process of the main pipeline austenitic stainless steel has been analyzed by the accelerated thermal aging test data. Then, the thermal aging residual-life prediction model based on the impact property degradation data is built by Bayesian updating methods. Finally, these models are applied in practical situations. It is shown that the proposed methods are feasible and the prediction accuracy meets the needs of the project. Also, it provides a foundation for the scientific management of aging management of the main pipeline. (authors)

  10. Demonstration of Passive Fuel Cell Thermal Management Technology

    Science.gov (United States)

    Burke, Kenneth A.; Jakupca, Ian; Colozza, Anthony; Wynne, Robert; Miller, Michael; Meyer, Al; Smith, William

    2012-01-01

    The NASA Glenn Research Center is developing advanced passive thermal management technology to reduce the mass and improve the reliability of space fuel cell systems for the NASA Exploration program. The passive thermal management system relies on heat conduction within highly thermally conductive cooling plates to move the heat from the central portion of the cell stack out to the edges of the fuel cell stack. Using the passive approach eliminates the need for a coolant pump and other cooling loop components within the fuel cell system which reduces mass and improves overall system reliability. Previous development demonstrated the performance of suitable highly thermally conductive cooling plates and integrated heat exchanger technology to collect the heat from the cooling plates (Ref. 1). The next step in the development of this passive thermal approach was the demonstration of the control of the heat removal process and the demonstration of the passive thermal control technology in actual fuel cell stacks. Tests were run with a simulated fuel cell stack passive thermal management system outfitted with passive cooling plates, an integrated heat exchanger and two types of cooling flow control valves. The tests were run to demonstrate the controllability of the passive thermal control approach. Finally, successful demonstrations of passive thermal control technology were conducted with fuel cell stacks from two fuel cell stack vendors.

  11. Enhancing reliability of ultrasonic testing of welds of nuclear power plant equipment

    International Nuclear Information System (INIS)

    Shcherbinskij, V.G.

    1981-01-01

    Results of investigation of factors influencing the reliability of manual ultrasonic testing of welded joints and weld deposited metal power-generating equipment are presented. Recommendations on the enhancing of reliability are given [ru

  12. The Comprehensive Snack Parenting Questionnaire (CSPQ: Development and Test-Retest Reliability

    Directory of Open Access Journals (Sweden)

    Dorus W. M. Gevers

    2018-04-01

    Full Text Available The narrow focus of existing food parenting instruments led us to develop a food parenting practices instrument measuring the full range of food practices constructs with a focus on snacking behavior. We present the development of the questionnaire and our research on the test-retest reliability. The developed Comprehensive Snack Parenting Questionnaire (CSPQ covers 21 constructs. Test-retest reliability was assessed by calculating intra class correlation coefficients and percentage agreement after two administrations of the CSPQ among a sample of 66 Dutch parents. Test-retest reliability analysis revealed acceptable intra class correlation coefficients (≥0.41 or agreement scores (≥0.60 for all items. These results, together with earlier work, suggest sufficient psychometric characteristics. The comprehensive, but brief CSPQ opens up chances for highly essential but unstudied research questions to understand and predict children’s snack intake. Example applications include studying the interactional nature of food parenting practices or interactions of food parenting with general parenting or child characteristics.

  13. Thermal cycling tests of actively cooled beryllium copper joints

    Energy Technology Data Exchange (ETDEWEB)

    Roedig, M.; Duwe, R.; Linke, J.; Schuster, A.; Wiechers, B. [Forschungszentrum Juelich GmbH (Germany)

    1998-01-01

    Screening tests (steady state heating) and thermal fatigue tests with several kinds of beryllium-copper joints have been performed in an electron beam facility. Joining techniques under investigation were brazing with silver containing and silver-free braze materials, hot isostatic pressing (HIP) and diffusion bonding (hot pressing). Best thermal fatigue performance was found for the brazed samples. (author)

  14. Reliability and accuracy of Cooper's test in male long distance runners

    Directory of Open Access Journals (Sweden)

    J.R. Alvero-Cruz

    2017-06-01

    Conclusions: All together, our results may confirm a good accuracy and reliability of Cooper's test in amateur long distance runners. Also, improvements or impairment lower than 52.2 m must not be associated with exercise training or retraining, since they are below the values of intra-subject reliability.

  15. Separate effects tests to determine the thermal dispersion in structured pebble beds in the PBMR HPTU test facility

    Energy Technology Data Exchange (ETDEWEB)

    Toit, C.G. du, E-mail: jat.dutoit@nwu.ac.za; Rousseau, P.G.; Kgame, T.L.

    2014-05-01

    Thermal-fluid simulations are used extensively to predict the maximum fuel temperatures, flows, pressure drops and thermal capacitance of pebble bed gas cooled reactors in support of the reactor safety case. The PBMR company developed the HTTF test facility in cooperation with M-Tech Industrial (Pty) Ltd. and the North-West University in South Africa to conduct comprehensive separate effects tests as well as integrated effects tests to study the different thermal-fluid phenomena. This paper describes the separate effects tests that were conducted to determine the effect of the porous structure on the fluid effective thermal conductivity due to the thermal dispersion. It also presents the methodology applied in the data analysis to derive the resultant values of the effective thermal conductivity and its associated uncertainty.

  16. Solid State Lighting Reliability Components to Systems

    CERN Document Server

    Fan, XJ

    2013-01-01

    Solid State Lighting Reliability: Components to Systems begins with an explanation of the major benefits of solid state lighting (SSL) when compared to conventional lighting systems including but not limited to long useful lifetimes of 50,000 (or more) hours and high efficacy. When designing effective devices that take advantage of SSL capabilities the reliability of internal components (optics, drive electronics, controls, thermal design) take on critical importance. As such a detailed discussion of reliability from performance at the device level to sub components is included as well as the integrated systems of SSL modules, lamps and luminaires including various failure modes, reliability testing and reliability performance. This book also: Covers the essential reliability theories and practices for current and future development of Solid State Lighting components and systems Provides a systematic overview for not only the state-of-the-art, but also future roadmap and perspectives of Solid State Lighting r...

  17. Reliability of a novel thermal imaging system for temperature assessment of healthy feet.

    Science.gov (United States)

    Petrova, N L; Whittam, A; MacDonald, A; Ainarkar, S; Donaldson, A N; Bevans, J; Allen, J; Plassmann, P; Kluwe, B; Ring, F; Rogers, L; Simpson, R; Machin, G; Edmonds, M E

    2018-01-01

    Thermal imaging is a useful modality for identifying preulcerative lesions ("hot spots") in diabetic foot patients. Despite its recognised potential, at present, there is no readily available instrument for routine podiatric assessment of patients at risk. To address this need, a novel thermal imaging system was recently developed. This paper reports the reliability of this device for temperature assessment of healthy feet. Plantar skin foot temperatures were measured with the novel thermal imaging device (Diabetic Foot Ulcer Prevention System (DFUPS), constructed by Photometrix Imaging Ltd) and also with a hand-held infrared spot thermometer (Thermofocus® 01500A3, Tecnimed, Italy) after 20 min of barefoot resting with legs supported and extended in 105 subjects (52 males and 53 females; age range 18 to 69 years) as part of a multicentre clinical trial. The temperature differences between the right and left foot at five regions of interest (ROIs), including 1st and 4th toes, 1st, 3rd and 5th metatarsal heads were calculated. The intra-instrument agreement (three repeated measures) and the inter-instrument agreement (hand-held thermometer and thermal imaging device) were quantified using intra-class correlation coefficients (ICCs) and the 95% confidence intervals (CI). Both devices showed almost perfect agreement in replication by instrument. The intra-instrument ICCs for the thermal imaging device at all five ROIs ranged from 0.95 to 0.97 and the intra-instrument ICCs for the hand-held-thermometer ranged from 0.94 to 0.97. There was substantial to perfect inter-instrument agreement between the hand-held thermometer and the thermal imaging device and the ICCs at all five ROIs ranged between 0.94 and 0.97. This study reports the performance of a novel thermal imaging device in the assessment of foot temperatures in healthy volunteers in comparison with a hand-held infrared thermometer. The newly developed thermal imaging device showed very good agreement in

  18. Comments on Thermal Physical Properties Testing Methods of Phase Change Materials

    Directory of Open Access Journals (Sweden)

    Jingchao Xie

    2013-01-01

    Full Text Available There is no standard testing method of the thermal physical properties of phase change materials (PCM. This paper has shown advancements in this field. Developments and achievements in thermal physical properties testing methods of PCM were commented, including differential scanning calorimetry, T-history measurement, the water bath method, and differential thermal analysis. Testing principles, advantages and disadvantages, and important points for attention of each method were discussed. A foundation for standardized testing methods for PCM was made.

  19. Reliability of candida skin test in the evaluation of T-cell function in ...

    African Journals Online (AJOL)

    Background: Both standardized and non-standardized candida skin tests are used in clinical practice for functional in-vivo assessment of cellular immunity with variable results and are considered not reliable under the age of 1 year. We sought to investigate the reliability of using manually prepared candida intradermal test ...

  20. Reliability

    OpenAIRE

    Condon, David; Revelle, William

    2017-01-01

    Separating the signal in a test from the irrelevant noise is a challenge for all measurement. Low test reliability limits test validity, attenuates important relationships, and can lead to regression artifacts. Multiple approaches to the assessment and improvement of reliability are discussed. The advantages and disadvantages of several different approaches to reliability are considered. Practical advice on how to assess reliability using open source software is provided.

  1. Content validity and reliability of test of gross motor development in Chilean children

    Directory of Open Access Journals (Sweden)

    Marcelo Cano-Cappellacci

    2015-01-01

    Full Text Available ABSTRACT OBJECTIVE To validate a Spanish version of the Test of Gross Motor Development (TGMD-2 for the Chilean population. METHODS Descriptive, transversal, non-experimental validity and reliability study. Four translators, three experts and 92 Chilean children, from five to 10 years, students from a primary school in Santiago, Chile, have participated. The Committee of Experts has carried out translation, back-translation and revision processes to determine the translinguistic equivalence and content validity of the test, using the content validity index in 2013. In addition, a pilot implementation was achieved to determine test reliability in Spanish, by using the intraclass correlation coefficient and Bland-Altman method. We evaluated whether the results presented significant differences by replacing the bat with a racket, using T-test. RESULTS We obtained a content validity index higher than 0.80 for language clarity and relevance of the TGMD-2 for children. There were significant differences in the object control subtest when comparing the results with bat and racket. The intraclass correlation coefficient for reliability inter-rater, intra-rater and test-retest reliability was greater than 0.80 in all cases. CONCLUSIONS The TGMD-2 has appropriate content validity to be applied in the Chilean population. The reliability of this test is within the appropriate parameters and its use could be recommended in this population after the establishment of normative data, setting a further precedent for the validation in other Latin American countries.

  2. Test-retest and between-site reliability in a multicenter fMRI study.

    Science.gov (United States)

    Friedman, Lee; Stern, Hal; Brown, Gregory G; Mathalon, Daniel H; Turner, Jessica; Glover, Gary H; Gollub, Randy L; Lauriello, John; Lim, Kelvin O; Cannon, Tyrone; Greve, Douglas N; Bockholt, Henry Jeremy; Belger, Aysenil; Mueller, Bryon; Doty, Michael J; He, Jianchun; Wells, William; Smyth, Padhraic; Pieper, Steve; Kim, Seyoung; Kubicki, Marek; Vangel, Mark; Potkin, Steven G

    2008-08-01

    In the present report, estimates of test-retest and between-site reliability of fMRI assessments were produced in the context of a multicenter fMRI reliability study (FBIRN Phase 1, www.nbirn.net). Five subjects were scanned on 10 MRI scanners on two occasions. The fMRI task was a simple block design sensorimotor task. The impulse response functions to the stimulation block were derived using an FIR-deconvolution analysis with FMRISTAT. Six functionally-derived ROIs covering the visual, auditory and motor cortices, created from a prior analysis, were used. Two dependent variables were compared: percent signal change and contrast-to-noise-ratio. Reliability was assessed with intraclass correlation coefficients derived from a variance components analysis. Test-retest reliability was high, but initially, between-site reliability was low, indicating a strong contribution from site and site-by-subject variance. However, a number of factors that can markedly improve between-site reliability were uncovered, including increasing the size of the ROIs, adjusting for smoothness differences, and inclusion of additional runs. By employing multiple steps, between-site reliability for 3T scanners was increased by 123%. Dropping one site at a time and assessing reliability can be a useful method of assessing the sensitivity of the results to particular sites. These findings should provide guidance toothers on the best practices for future multicenter studies.

  3. Innovative improvements of thermal response tests - Final report

    Energy Technology Data Exchange (ETDEWEB)

    Poppei, J.; Schwarz, R. [AF-Colenco Ltd, Baden (Switzerland); Peron, H.; Silvani, C; Steinmann, G.; Laloui, L. [Swiss Federal Institute of Technology, Laboratoire de Mecanique des Sols, Lausanne (Switzerland); Wagner, R.; Lochbuehler, T.; Rohner, E. [Geowatt AG, Zuerich (Switzerland)

    2008-12-15

    This illustrated final report for Swiss Federal Office of Energy (SFOE) takes a look at innovative improvements to thermal response tests that are used to investigate the thermo-physical properties of the ground for the purpose of dimensioning borehole heat exchangers. Recent technical developments in the borehole investigation tools area provide a promising prerequisite for improved estimates of thermal conductivity. A mini-module developed at the Swiss Federal Institute of Technology EPFL which is suitable for fast and flexible thermal response testing is discussed as is a wireless miniature data logger for continuous temperature recordings in borehole heat exchangers up to a depth of 350 m. This allows high-resolution vertical temperature profiling in boreholes. International state-of-the-art methods are reviewed. The adaptations to the analytical methods necessary for the effective application of these tools are discussed and numerical methods available are looked at. The testing of the methods developed and their results are discussed, as is the influence of ground-water flow.

  4. 3D thermography for improving temperature measurements in thermal vacuum testing

    Science.gov (United States)

    Robinson, D. W.; Simpson, R.; Parian, J. A.; Cozzani, A.; Casarosa, G.; Sablerolle, S.; Ertel, H.

    2017-09-01

    The application of thermography to thermal vacuum (TV) testing of spacecrafts is becoming a vital additional tool in the mapping of structures during thermal cycles and thermal balance (TB) testing. Many of the customers at the European Space Agency (ESA) test centre, European Space Research and Technology Centre (ESTEC), The Netherlands, now make use of a thermal camera during TB-TV campaigns. This complements the use of embedded thermocouples on the structure, providing the prospect of monitoring temperatures at high resolution and high frequency. For simple flat structures with a well-defined emissivity, it is possible to determine the surface temperatures with reasonable confidence. However, for most real spacecraft and sub-systems, the complexity of the structure's shape and its test environment creates inter-reflections from external structures. This and the additional complication of angular and spectral variations of the spacecraft surface emissivity make the interpretation of the radiation detected by a thermal camera more difficult in terms of determining a validated temperature with high confidence and well-defined uncertainty. One solution to this problem is: to map the geometry of the test specimen and thermal test environment; to model the surface temperatures and emissivity variations of the structures and materials; and to use this model to correct the apparent temperatures recorded by the thermal camera. This approach has been used by a team from NPL (National Physical Laboratory), Psi-tran, and PhotoCore, working with ESA, to develop a 3D thermography system to provide a means to validate thermal camera temperatures, based on a combination of thermal imaging photogrammetry and ray-tracing scene modeling. The system has been tested at ESTEC in ambient conditions with a dummy spacecraft structure containing a representative set of surface temperatures, shapes, and spacecraft materials, and with hot external sources and a high power lamp as a sun

  5. Test-Retest Reliability of the Salutogenic Wellness Promotion Scale (SWPS)

    Science.gov (United States)

    Anderson, L. M.; Moore, J. B.; Hayden, B. M.; Becker, C. M.

    2014-01-01

    Objective: This study examined the temporal stability (i.e. test-retest reliability) of the Salutogenic Wellness Promotion Scale (SWPS) using intraclass correlation coefficients (ICC). Current intraclass results were also compared to previously published interclass correlations to support the use of the intraclass method for test-retest…

  6. Reliability performance testing of totally encapsulating chemical protective suits

    International Nuclear Information System (INIS)

    Johnson, J.S.; Swearengen, P.M.

    1991-01-01

    The need to assure a high degree of reliability for totally encapsulating chemical protective (TECP) suits has been recognized by Lawrence Livermore National Laboratory's (LLNL) Hazards Control Department for some time. The following four tests were proposed as necessary to provide complete evaluation of TECP suit performance: 1. Quantitative leak test (ASTM draft), 2. Worst-case chemical exposure test (conceptual), 3. Pressure leak-rate test (complete, ASTM F1057-87), and 4. Chemical leak-rate test (ASTM draft). This paper reports on these tests which should be applied to measuring TECP suit performance in two stages: design qualification tests and field use tests. Test 1, 2, and 3 are used as design qualification tests, and tests 3 and 4 are used as field use tests

  7. Pretest Calculations of Temperature Changes for Field Thermal Conductivity Tests

    International Nuclear Information System (INIS)

    N.S. Brodsky

    2002-01-01

    A large volume fraction of the potential monitored geologic repository at Yucca Mountain may reside in the Tptpll (Tertiary, Paintbrush Group, Topopah Spring Tuff, crystal poor, lower lithophysal) lithostratigraphic unit. This unit is characterized by voids, or lithophysae, which range in size from centimeters to meters. A series of thermal conductivity field tests are planned in the Enhanced Characterization of the Repository Block (ECRB) Cross Drift. The objective of the pretest calculation described in this document is to predict changes in temperatures in the surrounding rock for these tests for a given heater power and a set of thermal transport properties. The calculation can be extended, as described in this document, to obtain thermal conductivity, thermal capacitance (density x heat capacity, J · m -3 · K -1 ), and thermal diffusivity from the field data. The work has been conducted under the ''Technical Work Plan For: Testing and Monitoring'' (BSC 2001). One of the outcomes of this analysis is to determine the initial output of the heater. This heater output must be sufficiently high that it will provide results in a reasonably short period of time (within several weeks or a month) and be sufficiently high that the heat increase is detectable by the instruments employed in the test. The test will be conducted in stages and heater output will be step increased as the test progresses. If the initial temperature is set too high, the experiment will not have as many steps and thus fewer thermal conductivity data points will result

  8. Technical report on the Piping Reliability Proving Tests at the Japan Atomic Energy Research Institute

    International Nuclear Information System (INIS)

    1993-05-01

    Japan Atomic Energy Research Institute (JAERI) conducts Piping Reliability Proving Tests from 1975 to 1992 based upon the contracts between JAERI and Science and Technology Agency of Japan (STA) under the auspices of the special account law for electric power development promotion. The purpose of these tests are to prove the structural reliability of the primary cooling piping constituting a part of the pressure boundary in the light water reactor power plants. The tests with large experimental facilities had ended already in 1990. Presently piping reliability analysis by the probabilistic fracture mechanics method is being done. Until now annual reports concerning the proving tests were produced and submitted to STA, whereas this report summarizes the test results done during these 16 years. Objectives of the piping reliability proving tests are to prove that the primary piping of the light water reactor (1) be reliable throughout the service period, (2) have no possibility of rupture, (3) bring no detrimental influence on the surrounding instrumentations or equipments near the break location even if it ruptured suddenly. To attain these objectives (i) pipe fatigue tests, (ii) unstable pipe fracture tests, (iii) pipe rupture tests and also the analyses by computer codes were done. After carrying out these tests, it is verified that the piping is reliable throughout the service period. The authors of this report are T. Isozaki, K. Shibata, S. Ueda, R. Kurihara, K. Onizawa and A. Kohsaka. The parts they wrote are shown in contents. (author)

  9. Cadmium safety rod thermal tests

    International Nuclear Information System (INIS)

    Thomas, J.K.; Iyer, N.C.; Peacock, H.B.

    1992-01-01

    Thermal testing of cadmium safety rods was conducted as part of a program to define the response of Savannah River Site (SRS) production reactor core components to a hypothetical LOCA leading to a drained reactor tank. The safety rods are present in the reactor core only during shutdown and are not used as a control mechanism during operation; thus, their response to the conditions predicted for the LOCA is only of interest to the extent that it could impact the progression of the accident. This document provides a description of this testing

  10. Intra-tester Reliability and Construct Validity of a Hip Abductor Eccentric Strength Test.

    Science.gov (United States)

    Brindle, Richard A; Ebaugh, D David; Milner, Clare E

    2017-11-15

    Side-lying hip abductor strength tests are commonly used to evaluate muscle strength. In a 'break' test the tester applies sufficient force to lower the limb to the table while the patient resists. The peak force is postulated to occur while the leg is lowering, thus representing the participant's eccentric muscle strength. However, it is unclear whether peak force occurs before or after the leg begins to lower. To determine intra-rater reliability and construct validity of a hip abductor eccentric strength test. Intra-rater reliability and construct validity study. Twenty healthy adults (26 ±6 years; 1.66 ±0.06 m; 62.2 ±8.0 kg) made two visits to the laboratory at least one week apart. During the hip abductor eccentric strength test, a hand-held dynamometer recorded peak force and time to peak force and limb position was recorded via a motion capture system. Intra-rater reliability was determined using intra-class correlation (ICC), standard error of measurement (SEM), and minimal detectable difference (MDD). Construct validity was assessed by determining if peak force occurred after the start of the lowering phase using a one-sample t-test. The hip abductor eccentric strength test had substantial intra-rater reliability (ICC( 3,3 ) = 0.88; 95% confidence interval: 0.65-0.95), SEM of 0.9%BWh, and a MDD of 2.5%BWh. Construct validity was established as peak force occurred 2.1s (±0.6s; range 0.7s to 3.7s) after the start of the lowering phase of the test (p ≤ 0.001). The hip abductor eccentric strength test is a valid and reliable measure of eccentric muscle strength. This test may be used clinically to assess changes in eccentric muscle strength over time.

  11. Preparation and properties of highly conductive palmitic acid/graphene oxide composites as thermal energy storage materials

    International Nuclear Information System (INIS)

    Mehrali, Mohammad; Latibari, Sara Tahan; Mehrali, Mehdi; Indra Mahlia, Teuku Meurah; Cornelis Metselaar, Hendrik Simon

    2013-01-01

    PA/GO (palmitic acid/graphene oxide) as PCMs (phase change materials) prepared by vacuum impregnation method, have high thermal conductivity. The GO (graphene oxide) composite was used as supporting material to improve thermal conductivity and shape stabilization of composite PCM (phase change material). SEM (Scanning electronic microscope), FT-IR (Fourier transformation infrared spectroscope) and XRD (X-ray diffractometer) were applied to determine microstructure, chemical structure and crystalloid phase of palmitic acid/GO composites, respectively. DSC (Differential scanning calorimeter) test was done to investigate thermal properties which include melting and solidifying temperatures and latent heat. FT-IR analysis represented that the composite instruction of porous palmitic acid and GO were physical. The temperatures of melting, freezing and latent heats of the composite measured through DSC analysis were 60.45, 60.05 °C, 101.23 and 101.49 kJ/kg, respectively. Thermal cycling test showed that the form-stable composite PCM has good thermal reliability and chemical stability. Thermal conductivity of the composite PCM was improved by more than three times from 0.21 to 1.02. As a result, due to their acceptable thermal properties, good thermal reliability, chemical stability and great thermal conductivities, we can consider the prepared form-stable composites as highly conductive PCMs for thermal energy storage applications. - Highlights: • Novel composite PCM with high thermal conductivity and latent heat storage. • New thermal cycling test for thermal reliability of composite PCMs. • Increasing thermal conductivity of composite PCM with graphene oxide. • Increasing thermal stability of phase change material by adding graphene oxide

  12. Thermal properties and reliability of eutectic mixture of stearic acid-acetamide as phase change material for latent heat storage

    International Nuclear Information System (INIS)

    Ma, Guixiang; Han, Lipeng; Sun, Jinhe; Jia, Yongzhong

    2017-01-01

    Highlights: • The system of stearic acid-acetamide binary mixtures were studied as phase change material. • The eutectic mixtures featured low melting temperatures and high latent heats of fusion for latent heat storage. • Solid-liquid phase diagrams for the system were constructed. • Negligible change in stability after 500 heating/cooling cycles. - Abstract: The thermal properties and reliability of the stearic acid (SA) with acetamide (AC) binary mixture were characterized using differential scanning calorimetry (DSC), powder X-ray diffraction (XRD), thermogravimetric analysis (TG) and Fourier transform infrared spectroscopy (FT-IR). The phase diagrams for the SA-AC binary mixture with AC in the metastable and the stable form were constructed. The eutectic system with stable AC is 0.604 mol fraction SA, and displayed a melting temperature (T m ) of 64.55 °C and latent heat of melting (ΔH m ) of 193.87 J·g −1 . The eutectic systems with metastable AC are 0.397 and 0.604 mol fraction SA. The melting temperatures are 62.23 °C and 62.54 °C, and latent heats of fusion are 222.10 J·g −1 and 194.28 J·g −1 , respectively. Following accelerated thermal cycling tests, TG and FT-IR analysis indicate that the eutectic mixture (χ SA = 0.397) with the metastable AC has good cyclic and thermal stability. The results show that the SA-AC eutectic mixture use as phase change material (PCM) possess good prospect for low temperature thermal energy storage (TES) applications.

  13. Standard Practice for Solar Simulation for Thermal Balance Testing of Spacecraft

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1973-01-01

    1.1 Purpose: 1.1.1 The primary purpose of this practice is to provide guidance for making adequate thermal balance tests of spacecraft and components where solar simulation has been determined to be the applicable method. Careful adherence to this practice should ensure the adequate simulation of the radiation environment of space for thermal tests of space vehicles. 1.1.2 A corollary purpose is to provide the proper test environment for systems-integration tests of space vehicles. An accurate space-simulation test for thermal balance generally will provide a good environment for operating all electrical and mechanical systems in their various mission modes to determine interferences within the complete system. Although adherence to this practice will provide the correct thermal environment for this type of test, there is no discussion of the extensive electronic equipment and procedures required to support systems-integration testing. 1.2 Nonapplicability—This practice does not apply to or provide inco...

  14. Impact on participation and autonomy: test of validity and reliability for older persons

    Directory of Open Access Journals (Sweden)

    Isabelle Ottenvall Hammar

    2014-10-01

    Full Text Available In research and healthcare it is important to measure older persons’ self-determination in order to improve their possibilities to decide for themselves in daily life. The questionnaire Impact on Participation and Autonomy (IPA assesses self-determination, but is not constructed for older persons. The aim of this study was to examine the validity and reliability of the IPA-S questionnaire for persons aged 70 years and older. The study was performed in two steps; first a validity test of the Swedish version of the questionnaire, IPA-S, followed by a reliability test-retest of an adjusted version. The validity was tested with focus groups and individual interviews on persons aged 77-88 years, and the reliability on persons aged 70-99 years. The validity test result showed that IPA-S is valid for older persons but it was too extensive and the phrasing of the items needed adjustments. The reliability test-retest on the adjusted questionnaire, IPA-Older persons (IPA-O, showed that 15 of 22 items had high agreement. IPA-O can be used to measure older persons’ self-determination in their care and rehabilitation.

  15. Reliability test: X-ray ring exit chambers crotch radiation absorbers. Final report

    International Nuclear Information System (INIS)

    Lynch, D.R.; Morgan, J.

    1999-01-01

    This report details the efforts by engineers at the National Synchrotron Light Source (NSLS) of Brookhaven National Laboratory (BNL) to evaluate the reliability of water-cooled radiation absorbers used in the NSLS X-ray ring. These absorbers are part of the 16 dipole vacuum chambers which comprise the arc sections of the ring. They are located at the intersections (crotch) of the beamline exit ports with the electron beam chamber, and are commonly referred to as crotches. The purpose of these efforts was to demonstrate the reliability of the crotches under operating conditions that the crotches will be subjected to over the entire expected life of the ring. The efforts described include engineering calculations, finite element analysis, conceptual design for a reliability test, test implementation and descriptions, results and conclusions related to these analyses and tests

  16. Evaluation of Specimen Geometric Effect for Laser Flash Thermal Diffusivity Test

    International Nuclear Information System (INIS)

    Park, Dae Gyu; Kim, Hee Moon; Song, Woong Sub; Baik, Seung Je; Ryu, Woo Seok; Ahn, Sang Bok; Joo, Young Sun

    2012-01-01

    KAERI(Korea Atomic Energy Research Institute) is developing a new type of nuclear reactor, the so called 'SMART' (System Integrated Modular Advanced Reactor) reactor. Alloy 690 was selected as the candidate material for the heat exchanger tube of of SMART's steam generator. The SMART R and D is now facing the stage of engineering verification and standard design approval for application of DEMO reactors. Therefore, the material performance under the relevant environment needs to be evaluated. The one of the important material performance issues is thermal conductivity, which the engineering database is necessary for the steam generator design. However, the neutron post irradiation characteristics of alloy 690 are little known. As a result, a PIE (Post Irradiation Examination) of the thermal properties have been plan for a 4 times, so called base line test, 1 st irradiation test, 2 nd and 3 rd irradiation test. But there is some constraint to perform thermal diffusivity test owing to test specimen. Originally thermal diffusivity test are planed using disk shape with 9 mm diameter and 1 mm thick specimen. Due to mismatch of neutron irradiation schedule, thermal diffusivity will be tested by different shape and size specimens at 1 st irradiation test. Therefore, verification of geometric and size effect are necessary for test specimen in order to achieve accurate test results

  17. Perform qualify reliability-power tests by shooting common mistakes: practical problems and standard answers per Telcordia/Bellcore requests

    Science.gov (United States)

    Yu, Zheng

    2002-08-01

    Facing the new demands of the optical fiber communications market, almost all the performance and reliability of optical network system are dependent on the qualification of the fiber optics components. So, how to comply with the system requirements, the Telcordia / Bellcore reliability and high-power testing has become the key issue for the fiber optics components manufacturers. The qualification of Telcordia / Bellcore reliability or high-power testing is a crucial issue for the manufacturers. It is relating to who is the outstanding one in the intense competition market. These testing also need maintenances and optimizations. Now, work on the reliability and high-power testing have become the new demands in the market. The way is needed to get the 'Triple-Win' goal expected by the component-makers, the reliability-testers and the system-users. To those who are meeting practical problems for the testing, there are following seven topics that deal with how to shoot the common mistakes to perform qualify reliability and high-power testing: ¸ Qualification maintenance requirements for the reliability testing ¸ Lots control for preparing the reliability testing ¸ Sampling select per the reliability testing ¸ Interim measurements during the reliability testing ¸ Basic referencing factors relating to the high-power testing ¸ Necessity of re-qualification testing for the changing of producing ¸ Understanding the similarity for product family by the definitions

  18. Scoping analysis of in situ thermal-hydrological testing at Yucca Mountain

    International Nuclear Information System (INIS)

    Buscheck, T.A.; Nitao, J.J.

    1996-01-01

    In situ thermal tests, which are to be conducted in the Exploratory Studies Facility (ESF) in the unsaturated zone (UZ) at Yucca Mountain, are required to test coupled thermal-hydrological-geomechanical-geochemical (T-H-M-C) process models that support total system performance assessment. The ESF thermal tests must provide an understanding of coupled T-H-M-C processes that are relevant to expected repository conditions. Current planning includes the possibility of two large-scale tests: (1) the first ESF (drift-scale) thermal test, which will be conducted under an accelerated heatup and cooldown schedule, and (2) a second ESF (multi-drift) test, which will be larger-scale, longer-duration test, conducted under a less accelerated heatup and cooldown schedule. With the V-TOUGH (vectorized transport of unsaturated groundwater and heat) code, the authors modeled and evaluated a range of heater test sizes, heating rates, and heating durations under a range of plausible hydrological conditions to develop a test design that provides sufficient (and timely) information to determine the following: the dominant mode(s) of heat flow; the major T-H regime(s) and the T-H-M-C processes that determine the magnitude and direction of vapor and condensate flow; and the influence of heterogeneous conditions on the flow of heat, vapor, and condensate. A major purpose of the ESF thermal tests is to determine which major decay-heat-driven T-H flow regime(s) will govern the magnitude and direction of vapor and condensate flow in the UZ. Another major purpose of the thermal tests is to determine the degree of vapor diffusion enhancement

  19. A Comparison of the Approaches of Generalizability Theory and Item Response Theory in Estimating the Reliability of Test Scores for Testlet-Composed Tests

    Science.gov (United States)

    Lee, Guemin; Park, In-Yong

    2012-01-01

    Previous assessments of the reliability of test scores for testlet-composed tests have indicated that item-based estimation methods overestimate reliability. This study was designed to address issues related to the extent to which item-based estimation methods overestimate the reliability of test scores composed of testlets and to compare several…

  20. Accounting for Proof Test Data in a Reliability Based Design Optimization Framework

    Science.gov (United States)

    Ventor, Gerharad; Scotti, Stephen J.

    2012-01-01

    This paper investigates the use of proof (or acceptance) test data during the reliability based design optimization of structural components. It is assumed that every component will be proof tested and that the component will only enter into service if it passes the proof test. The goal is to reduce the component weight, while maintaining high reliability, by exploiting the proof test results during the design process. The proposed procedure results in the simultaneous design of the structural component and the proof test itself and provides the designer with direct control over the probability of failing the proof test. The procedure is illustrated using two analytical example problems and the results indicate that significant weight savings are possible when exploiting the proof test results during the design process.

  1. Test–re-test reliability and inter-rater reliability of a digital pelvic inclinometer in young, healthy males and females

    OpenAIRE

    Chris Beardsley; Tim Egerton; Brendon Skinner

    2016-01-01

    Objective. The purpose of this study was to investigate the reliability of a digital pelvic inclinometer (DPI) for measuring sagittal plane pelvic tilt in 18 young, healthy males and females.\\ud \\ud Method. The inter-rater reliability and test–re-test reliabilities of the DPI for measuring pelvic tilt in standing on both the right and left sides of the pelvis were measured by two raters carrying out two rating sessions of the same subjects, three weeks apart.\\ud \\ud Results. For measuring pel...

  2. Test-retest reliability of trunk accelerometric gait analysis

    DEFF Research Database (Denmark)

    Henriksen, Marius; Lund, Hans; Moe-Nilssen, R

    2004-01-01

    The purpose of this study was to determine the test-retest reliability of a trunk accelerometric gait analysis in healthy subjects. Accelerations were measured during walking using a triaxial accelerometer mounted on the lumbar spine of the subjects. Six men and 14 women (mean age 35.2; range 18...... a definite potential in clinical gait analysis....

  3. Test of Creative Imagination: Validity and Reliability Study

    Science.gov (United States)

    Gundogan, Aysun; Ari, Meziyet; Gonen, Mubeccel

    2013-01-01

    The purpose of this study was to investigate validity and reliability of the test of creative imagination. This study was conducted with the participation of 1000 children, aged between 9-14 and were studying in six primary schools in the city center of Denizli Province, chosen by cluster ratio sampling. In the study, it was revealed that the…

  4. Reliability Of Kraus-Weber Exercise Test As An Evaluation Tool In ...

    African Journals Online (AJOL)

    Reliability Of Kraus-Weber Exercise Test As An Evaluation Tool In Low Back ... strength and flexibility of the back, abdominal, psoas and hamstring muscles. ... Keywords: Kraus-Weber test, low back pain, muscle flexibility, muscle strength.

  5. Reliability of wind turbine blades: An overview of materials testing

    DEFF Research Database (Denmark)

    Holmes, John W.; Sørensen, Bent F.; Brøndsted, Povl

    2007-01-01

    an understanding of how damage develops in composite structures, composite materials and adhesives. Designing reliable wind turbine blades also requires the further development of laboratory scale and full scale test methods to evaluate the structural response and durability of new materials under various loading......The structural reliability of wind turbine components can have a profound impact on both the profitability and reputation of a wind turbine manufacturer or supplier of wind turbine components. The issue of reliability is of critical concern when large wind farm co-operatives are considered......, and when wind turbines are located in remote regions where the cost of inspections and repairs can be very high. From a structural viewpoint, wind turbine blades are subjected to very complex loading histories with coupled deformation modes. The long-term reliability of wind turbine blades requires...

  6. Preliminary data evaluation for thermal insulation characterization testing

    International Nuclear Information System (INIS)

    DeClue, J.F.; Moses, S.D.; Tollefson, D.A.

    1991-01-01

    The purpose of Thermal Insulation Characterization Testing is to provide physical data to support certain assumptions and calculational techniques used in the criticality safety calculations in Section 6 of the Safety Analysis Reports for Packaging (SARPs) for drum-type packaging for Department of Energy's (DOE) Oak Ridge Y-12 Plant, managed by Martin Marietta Energy Systems, Inc. Results of preliminary data evaluation regarding the fire-test condition reveal that realistic weight loss consideration and residual material characterization in developing calculational models for the hypothetical accident condition is necessary in order to prevent placement of unduly conservative restrictions on shipping requirements as a result of overly conservative modeling. This is particularly important for fast systems. Determination of the geometric arrangement of residual material is of secondary importance. Both the methodology used to determine the minimum thermal insulation mass remaining after the fire test and the treatment of the thermal insulation in the criticality safety calculational models requires additional evaluation. Specific testing to be conducted will provide experimental data with which to validate the mass estimates and calculational modeling techniques for extrapolation to generic drum-type containers

  7. Test-retest reliability of sensor-based sit-to-stand measures in young and older adults.

    Science.gov (United States)

    Regterschot, G Ruben H; Zhang, Wei; Baldus, Heribert; Stevens, Martin; Zijlstra, Wiebren

    2014-01-01

    This study investigated test-retest reliability of sensor-based sit-to-stand (STS) peak power and other STS measures in young and older adults. In addition, test-retest reliability of the sensor method was compared to test-retest reliability of the Timed Up and Go Test (TUGT) and Five-Times-Sit-to-Stand Test (FTSST) in older adults. Ten healthy young female adults (20-23 years) and 31 older adults (21 females; 73-94 years) participated in two assessment sessions separated by 3-8 days. Vertical peak power was assessed during three (young adults) and five (older adults) normal and fast STS trials with a hybrid motion sensor worn on the hip. Older adults also performed the FTSST and TUGT. The average sensor-based STS peak power of the normal STS trials and the average sensor-based STS peak power of the fast STS trials showed excellent test-retest reliability in young adults (intra-class correlation (ICC)≥0.90; zero in 95% confidence interval of mean difference between test and retest (95%CI of D); standard error of measurement (SEM)≤6.7% of mean peak power) and older adults (ICC≥0.91; zero in 95%CI of D; SEM≤9.9%). Test-retest reliability of sensor-based STS peak power and TUGT (ICC=0.98; zero in 95%CI of D; SEM=8.5%) was comparable in older adults, test-retest reliability of the FTSST was lower (ICC=0.73; zero outside 95%CI of D; SEM=14.4%). Sensor-based STS peak power demonstrated excellent test-retest reliability and may therefore be useful for clinical assessment of functional status and fall risk. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Dormancy effects on the reliability of nuclear thermal propulsion systems for long-term manned space missions

    International Nuclear Information System (INIS)

    Shooman, M.L.; Sforza, P.M.

    1993-01-01

    This paper explores the effects of dormancy on the reliability of a Nuclear Thermal Propulsion (NTP) system for long-term manned space missions, such as Mars exploration. Dormancy refers to the portion of space systems operation where the power and stress levels are significantly reduced from nominal values and the authors have identified dormancy as a significant effect. Three approaches are used to evaluate the relative importance of failure rates during dormant operation: use of failure rate models involving dormancy, power cycling and fully energized operation; study of data bases which include both dormant and energized failure rates; predictions based on an Arrhenius rate process formulation. The results of these approaches suggest that for a long term manned mission the dormancy, cycle, and energized failure rates will all be important. Reliability in the energized state normally receives utmost attention and care during design, however, unless equal attention is directed to dormancy, the mission reliability may be severely compromised

  9. The reliability of physical examination tests for the diagnosis of anterior cruciate ligament rupture--A systematic review.

    Science.gov (United States)

    Lange, Toni; Freiberg, Alice; Dröge, Patrik; Lützner, Jörg; Schmitt, Jochen; Kopkow, Christian

    2015-06-01

    Systematic literature review. Despite their frequent application in routine care, a systematic review on the reliability of clinical examination tests to evaluate the integrity of the ACL is missing. To summarize and evaluate intra- and interrater reliability research on physical examination tests used for the diagnosis of ACL tears. A comprehensive systematic literature search was conducted in MEDLINE, EMBASE and AMED until May 30th 2013. Studies were included if they assessed the intra- and/or interrater reliability of physical examination tests for the integrity of the ACL. Methodological quality was evaluated with the Quality Appraisal of Reliability Studies (QAREL) tool by two independent reviewers. 110 hits were achieved of which seven articles finally met the inclusion criteria. These studies examined the reliability of four physical examination tests. Intrarater reliability was assessed in three studies and ranged from fair to almost perfect (Cohen's k = 0.22-1.00). Interrater reliability was assessed in all included studies and ranged from slight to almost perfect (Cohen's k = 0.02-0.81). The Lachman test is the physical tests with the highest intrarater reliability (Cohen's k = 1.00), the Lachman test performed in prone position the test with the highest interrater reliability (Cohen's k = 0.81). Included studies were partly of low methodological quality. A meta-analysis could not be performed due to the heterogeneity in study populations, reliability measures and methodological quality of included studies. Systematic investigations on the reliability of physical examination tests to assess the integrity of the ACL are scarce and of varying methodological quality. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. A New Tool for Nutrition App Quality Evaluation (AQEL): Development, Validation, and Reliability Testing.

    Science.gov (United States)

    DiFilippo, Kristen Nicole; Huang, Wenhao; Chapman-Novakofski, Karen M

    2017-10-27

    The extensive availability and increasing use of mobile apps for nutrition-based health interventions makes evaluation of the quality of these apps crucial for integration of apps into nutritional counseling. The goal of this research was the development, validation, and reliability testing of the app quality evaluation (AQEL) tool, an instrument for evaluating apps' educational quality and technical functionality. Items for evaluating app quality were adapted from website evaluations, with additional items added to evaluate the specific characteristics of apps, resulting in 79 initial items. Expert panels of nutrition and technology professionals and app users reviewed items for face and content validation. After recommended revisions, nutrition experts completed a second AQEL review to ensure clarity. On the basis of 150 sets of responses using the revised AQEL, principal component analysis was completed, reducing AQEL into 5 factors that underwent reliability testing, including internal consistency, split-half reliability, test-retest reliability, and interrater reliability (IRR). Two additional modifiable constructs for evaluating apps based on the age and needs of the target audience as selected by the evaluator were also tested for construct reliability. IRR testing using intraclass correlations (ICC) with all 7 constructs was conducted, with 15 dietitians evaluating one app. Development and validation resulted in the 51-item AQEL. These were reduced to 25 items in 5 factors after principal component analysis, plus 9 modifiable items in two constructs that were not included in principal component analysis. Internal consistency and split-half reliability of the following constructs derived from principal components analysis was good (Cronbach alpha >.80, Spearman-Brown coefficient >.80): behavior change potential, support of knowledge acquisition, app function, and skill development. App purpose split half-reliability was .65. Test-retest reliability showed no

  11. Five times sit-to-stand test in subjects with total knee replacement: Reliability and relationship with functional mobility tests.

    Science.gov (United States)

    Medina-Mirapeix, Francesc; Vivo-Fernández, Iván; López-Cañizares, Juan; García-Vidal, José A; Benítez-Martínez, Josep Carles; Del Baño-Aledo, María Elena

    2018-01-01

    The objective was to determine the inter-observer and test/retest reliability of the "Five-repetition sit-to-stand" (5STS) test in patients with total knee replacement (TKR). To explore correlation between 5STS and two mobility tests. A reliability study was conducted among 24 (mean age 72.13, S.D. 10.67; 50% were women) outpatients with TKR. They were recruited from a traumatology unit of a public hospital via convenience sampling. A physiotherapist and trauma physician assessed each patient at the same time. The same physiotherapist realized a 5STS second measurement 45-60min after the first one. Reliability was assessed with intraclass correlation coefficients (ICCs) and Bland-Altman plots. Pearson coefficient was calculated to assess the correlation between 5STS, time up to go test (TUG) and four meters gait speed (4MGS). ICC for inter-observer and test-retest reliability of the 5STS were 0.998 (95% confidence interval [CI], 0.995-0.999) and 0.982 (95% CI, 0.959-0.992). Bland-Altman plot inter-observer showed limits between -0.82 and 1.06 with a mean of 0.11 and no heteroscedasticity within the data. Bland-Altman plot for test-retest showed the limits between 1.76 and 4.16, a mean of 1.20 and heteroscedasticity within the data. Pearson correlation coefficient revealed significant correlation between 5STS and TUG (r=0.7, ptest-retest reliability when it is used in people with TKR, and also significant correlation with other functional mobility tests. These findings support the use of 5STS as outcome measure in TKR population. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Reliability of physical examination tests for the diagnosis of knee disorders: Evidence from a systematic review.

    Science.gov (United States)

    Décary, Simon; Ouellet, Philippe; Vendittoli, Pascal-André; Desmeules, François

    2016-12-01

    Clinicians often rely on physical examination tests to guide them in the diagnostic process of knee disorders. However, reliability of these tests is often overlooked and may influence the consistency of results and overall diagnostic validity. Therefore, the objective of this study was to systematically review evidence on the reliability of physical examination tests for the diagnosis of knee disorders. A structured literature search was conducted in databases up to January 2016. Included studies needed to report reliability measures of at least one physical test for any knee disorder. Methodological quality was evaluated using the QAREL checklist. A qualitative synthesis of the evidence was performed. Thirty-three studies were included with a mean QAREL score of 5.5 ± 0.5. Based on low to moderate quality evidence, the Thessaly test for meniscal injuries reached moderate inter-rater reliability (k = 0.54). Based on moderate to excellent quality evidence, the Lachman for anterior cruciate ligament injuries reached moderate to excellent inter-rater reliability (k = 0.42 to 0.81). Based on low to moderate quality evidence, the Tibiofemoral Crepitus, Joint Line and Patellofemoral Pain/Tenderness, Bony Enlargement and Joint Pain on Movement tests for knee osteoarthritis reached fair to excellent inter-rater reliability (k = 0.29 to 0.93). Based on low to moderate quality evidence, the Lateral Glide, Lateral Tilt, Lateral Pull and Quality of Movement tests for patellofemoral pain reached moderate to good inter-rater reliability (k = 0.49 to 0.73). Many physical tests appear to reach good inter-rater reliability, but this is based on low-quality and conflicting evidence. High-quality research is required to evaluate the reliability of knee physical examination tests. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Validation of the thermal-hydraulic system code ATHLET based on selected pressure drop and void fraction BFBT tests

    Energy Technology Data Exchange (ETDEWEB)

    Di Marcello, Valentino, E-mail: valentino.marcello@kit.edu; Escalante, Javier Jimenez; Espinoza, Victor Sanchez

    2015-07-15

    Highlights: • Simulation of BFBT-BWR steady-state and transient tests with ATHLET. • Validation of thermal-hydraulic models based on pressure drops and void fraction measurements. • TRACE system code is used for the comparative study. • Predictions result in a good agreement with the experiments. • Discrepancies are smaller or comparable with respect to the measurements uncertainty. - Abstract: Validation and qualification of thermal-hydraulic system codes based on separate effect tests are essential for the reliability of numerical tools when applied to nuclear power plant analyses. To this purpose, the Institute for Neutron Physics and Reactor Technology (INR) at the Karlsruhe Institute of Technology (KIT) is involved in various validation and qualification activities of different CFD, sub-channel and system codes. In this paper, the capabilities of the thermal-hydraulic code ATHLET are assessed based on the experimental results provided within the NUPEC BFBT benchmark related to key Boiling Water Reactors (BWR) phenomena. Void fraction and pressure drops measurements in the BFBT bundle performed under steady-state and transient conditions which are representative for e.g. turbine trip and recirculation pump trip events, are compared with the numerical results of ATHLET. The comparison of code predictions with the BFBT data has shown good agreement given the experimental uncertainty and the results are consistent with the trends obtained with similar thermal-hydraulic codes.

  14. Reliability of fitness tests using methods and time periods common in sport and occupational management.

    Science.gov (United States)

    Burnstein, Bryan D; Steele, Russell J; Shrier, Ian

    2011-01-01

    Fitness testing is used frequently in many areas of physical activity, but the reliability of these measurements under real-world, practical conditions is unknown. To evaluate the reliability of specific fitness tests using the methods and time periods used in the context of real-world sport and occupational management. Cohort study. Eighteen different Cirque du Soleil shows. Cirque du Soleil physical performers who completed 4 consecutive tests (6-month intervals) and were free of injury or illness at each session (n = 238 of 701 physical performers). Performers completed 6 fitness tests on each assessment date: dynamic balance, Harvard step test, handgrip, vertical jump, pull-ups, and 60-second jump test. We calculated the intraclass coefficient (ICC) and limits of agreement between baseline and each time point and the ICC over all 4 time points combined. Reliability was acceptable (ICC > 0.6) over an 18-month time period for all pairwise comparisons and all time points together for the handgrip, vertical jump, and pull-up assessments. The Harvard step test and 60-second jump test had poor reliability (ICC < 0.6) between baseline and other time points. When we excluded the baseline data and calculated the ICC for 6-month, 12-month, and 18-month time points, both the Harvard step test and 60-second jump test demonstrated acceptable reliability. Dynamic balance was unreliable in all contexts. Limit-of-agreement analysis demonstrated considerable intraindividual variability for some tests and a learning effect by administrators on others. Five of the 6 tests in this battery had acceptable reliability over an 18-month time frame, but the values for certain individuals may vary considerably from time to time for some tests. Specific tests may require a learning period for administrators.

  15. The push-off test: development of a simple, reliable test of upper extremity weight-bearing capability.

    Science.gov (United States)

    Vincent, Joshua I; MacDermid, Joy C; Michlovitz, Susan L; Rafuse, Richard; Wells-Rowsell, Christina; Wong, Owen; Bisbee, Leslie

    2014-01-01

    Longitudinal clinical measurement study. The push-off test (POT) is a novel and simple measure of upper extremity weight-bearing that can be measured with a grip dynamometer. There are no published studies on the validity and reliability of the POT. The relationship between upper extremity self-report activity/participation and impairment measures remain an unexplored realm. The primary purpose of this study is to estimate the intra and inter-rater reliability and construct validity of the POT. The secondary purpose is to estimate the relationship between upper extremity self-report activity/participation questionnaires and impairment measures. A convenience sample of 22 patients with wrist or elbow injuries were tested for POT, wrist/elbow range of motion (ROM), isometric wrist extension strength (WES) and grip strength; and completed two self-report activity/participation questionnaires: Disability of the Arm, Shoulder and the Hand (DASH) and Work Limitations Questionnaire (WLQ-26). POT's inter and intra-rater reliability and construct validity was tested. Pearson's correlations were run between the impairment measures and self-report questionnaires to look into the relationship amongst them. The POT demonstrated high inter-rater reliability (ICC affected = 0.97; 95% C.I. 0.93-0.99; ICC unaffected = 0.85; 95% C.I. 0.68-0.94) and intra-rater reliability (ICC affected = 0.96; 95% C.I. 0.92-0.97; ICC unaffected = 0.92; 95% C.I. 0.85-0.97). The POT was correlated moderately with the DASH (r = -0.47; p = 0.03). While examining the relationship between upper extremity self-reported activity/participation questionnaires and impairment measures the strongest correlation was between the DASH and the POT (r = -0.47; p = 0.03) and none of the correlations with the other physical impairment measures reached significance. At-work disability demonstrated insignificant correlations with physical impairments. The POT test provides a reliable and easily

  16. Photovoltaic module reliability improvement through application testing and failure analysis

    Science.gov (United States)

    Dumas, L. N.; Shumka, A.

    1982-01-01

    During the first four years of the U.S. Department of Energy (DOE) National Photovoltatic Program, the Jet Propulsion Laboratory Low-Cost Solar Array (LSA) Project purchased about 400 kW of photovoltaic modules for test and experiments. In order to identify, report, and analyze test and operational problems with the Block Procurement modules, a problem/failure reporting and analysis system was implemented by the LSA Project with the main purpose of providing manufacturers with feedback from test and field experience needed for the improvement of product performance and reliability. A description of the more significant types of failures is presented, taking into account interconnects, cracked cells, dielectric breakdown, delamination, and corrosion. Current design practices and reliability evaluations are also discussed. The conducted evaluation indicates that current module designs incorporate damage-resistant and fault-tolerant features which address field failure mechanisms observed to date.

  17. A New Reliability Analysis Model of the Chegongzhuang Heat-Supplying Tunnel Structure Considering the Coupling of Pipeline Thrust and Thermal Effect

    Directory of Open Access Journals (Sweden)

    Jiawen Zhang

    2018-02-01

    Full Text Available Based on the operating Chegongzhuang heat-supplying tunnel in Beijing, the reliability of its lining structure under the action of large thrust and thermal effect is studied. According to the characteristics of a heat-supplying tunnel service, a three-dimensional numerical analysis model was established based on the mechanical tests on the in-situ specimens. The stress and strain of the tunnel structure were obtained before and after the operation. Compared with the field monitoring data, the rationality of the model was verified. After extracting the internal force of the lining structure, the improved method of subset simulation was proposed as the performance function to calculate the reliability of the main control section of the tunnel. In contrast to the traditional calculation method, the analytic relationship between the sample numbers in the subset simulation method and Monte Carlo method was given. The results indicate that the lining structure is greatly influenced by coupling in the range of six meters from the fixed brackets, especially the tunnel floor. The improved subset simulation method can greatly save computation time and improve computational efficiency under the premise of ensuring the accuracy of calculation. It is suitable for the reliability calculation of tunnel engineering, because “the lower the probability, the more efficient the calculation.”

  18. Thermal Vacuum Integrated System Test at B-2

    Science.gov (United States)

    Kudlac, Maureen T.; Weaver, Harold F.; Cmar, Mark D.

    2012-01-01

    The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) Plum Brook Station (PBS) Space Propulsion Research Facility, commonly referred to as B-2, is NASA s third largest thermal vacuum facility. It is the largest designed to store and transfer large quantities of liquid hydrogen and liquid oxygen, and is perfectly suited to support developmental testing of chemical propulsion systems as well as fully integrated stages. The facility is also capable of providing thermal-vacuum simulation services to support testing of large lightweight structures, Cryogenic Fluid Management (CFM) systems, electric propulsion test programs, and other In-Space propulsion programs. A recently completed integrated system test demonstrated the refurbished thermal vacuum capabilities of the facility. The test used the modernized data acquisition and control system to monitor the facility during pump down of the vacuum chamber, operation of the liquid nitrogen heat sink (or cold wall) and the infrared lamp array. A vacuum level of 1.3x10(exp -4)Pa (1x10(exp -6)torr) was achieved. The heat sink provided a uniform temperature environment of approximately 77 K (140deg R) along the entire inner surface of the vacuum chamber. The recently rebuilt and modernized infrared lamp array produced a nominal heat flux of 1.4 kW/sq m at a chamber diameter of 6.7 m (22 ft) and along 11 m (36 ft) of the chamber s cylindrical vertical interior. With the lamp array and heat sink operating simultaneously, the thermal systems produced a heat flux pattern simulating radiation to space on one surface and solar exposure on the other surface. The data acquired matched pretest predictions and demonstrated system functionality.

  19. The new features of the ExaMe evaluation system and reliability of its fixed tests.

    Science.gov (United States)

    Martinková, P; Zvára, K; Zvárová, J; Zvára, K

    2006-01-01

    The ExaMe system for the evaluation of targeted knowledge has been in development since 1998. The new features of the ExaMe system are introduced in this paper. Especially, the new three-layer architecture is described. Besides the system itself, the properties of fixed tests in the ExaMe system are studied. In special detail, the reliability of the fixed tests is discussed. The theory background is explained and some limitations of the reliability are pointed out. Three characteristics used for estimation of reliability of educational tests are discussed: Cronbach's alpha, standardized item alpha and split half coefficient. The relation between these characteristics and reliability and between characteristics themselves is investigated. In more detail, the properties of Cronbach's alpha, the characteristics mostly used for the estimation of reliability, are discussed. A confidence interval is introduced for the characteristics. Since 2000, the serviceability of the ExaMe evaluation system as the supporting evaluation tool has been repeatedly shown at the courses of Ph.D. studies in biomedical informatics at Charles University in Prague. The ExaMe system also opens new possibilities for self-evaluation and distance learning, especially when connected with electronic books on the Internet. The estimation of reliability of tests contains some limitations. Keeping them in mind, we can still get some information about the quality of certain educational tests. Therefore, the estimation of reliability of the fixed tests is implemented in the ExaMe system.

  20. Fire testing and analysis of TRUPACT-I Thermal Test Article

    International Nuclear Information System (INIS)

    Romesberg, L.E.; Longenbaugh, R.S.; Joseph, B.J.

    1989-02-01

    This report documents the fabrication and thermal test of a full-scale prototype of the revised TRUPACT-I design. The fire test demonstrated that the response of the Test Article to a jet-fueled pool fire, subsequent to the impact and puncture tests, meets the impact, puncture, and thermal performance requirements of the regulations governing transport of radioactive materials. The Test Article was a replica of the front half (closure end) of the revised TRUPACT-I design. To simulate the cumulative effect of the regulatory hypothetical accident sequence, the Test Article included the structural damage found in TRUPACT-I, Unit 0 after regulatory drop and puncture testing. The Test Article was totally engulfed in a pool fire fueled by JP-4 jet fuel for 46 minutes. The maximum temperature reached at the inner door seals was 149/degree/C (300/degree/F) and the maximum temperature at the inner door filters was 171/degree/C (340/degree/F). Both temperatures are within the normal working range for these components. Post-test leak rate measurements of 0.0041 atm-cm 3 /s (ANSI standard air) between the innermost pair of door seals and 0.0046 atm-cm 3 /s (ANSI standard air) between the outermost pair of door seals verified that the performance of the silicone seals met the design requirements. Since no detectable leakage was measured to a sensitivity of 1.0E-7 atm-cm 3 /s for the filter installation seal or quick-connect valve seal post-test, the total leak rate for the containment system was less than the maximum allowable 0.01 atm-cm 3 /s (ANSI standard air). 10 refs., 52 figs., 5 tabs

  1. Acoustic stapedial reflexes in healthy neonates: normative data and test-retest reliability.

    Science.gov (United States)

    Kei, Joseph

    2012-01-01

    The acoustic stapedial reflex (ASR) test provides useful information about the function of the auditory system. While it is frequently used with adults and children in a clinical setting, its use with young infants is limited. Presently, there are few data for neonates and inadequate research into the test-retest reliability of the ASR test. This study aimed to establish normative data and evaluate the test-retest reliability of the ASR test in healthy neonates. A cross-sectional experimental design was used to establish ASR normative data and assess the test-retest reliability of ASR thresholds obtained from healthy neonates. Sixty-eight full-term neonates with mean chronological age of 2.5 days (SD = 1.8 day), who passed the automated auditory brainstem response, transient evoked otoacoustic emission, and high frequency (1 kHz) tympanometry (HFT) tests. One randomly selected ear from each neonate was tested using TEOAE (transient evoked otoacoustic emission), HFT, and ASR tests using a 1 kHz probe tone. ASR thresholds were elicited by presenting pure tones of 0.5, 2, and 4 kHz and broadband noise (BBN) separately to the test ear in an ipsilateral stimulation mode. The ASR procedure was repeated to acquire retest data within the same testing session. Descriptive statistics, χ2, and analysis of variance with repeated measures tests were used to analyze ASR data. All neonates exhibited ASR when stimulated by tonal stimuli or BBN. The mean ASRTs (acoustic stapedial reflex thresholds) for the 0.5, 2, and 4 kHz tones were 81.6 ± 7.9, 71.3 ± 7.9, and 65.4 ± 8.7 dB HL, respectively. The mean ASRT for the BBN was estimated to be smaller than 57.2 dB HL, given the limitation of the equipment. The 95th percentiles of the ASRT were 95, 85, 80, and 75 dB HL for the 0.5, 2, and 4 kHz and BBN, respectively. The test-retest reliability of the ASR test for all stimuli was high, with no significant difference in mean ASRTs across the test and retest conditions. Test

  2. Comparison of reading performance tests concerning difficulty of sentences and paragraphs and their reliability

    NARCIS (Netherlands)

    Brussee, T.; van Nispen, R.M.A.; Klerkx, E.M.F.J.; Knol, D.L.; van Rens, G.H.M.B.

    2015-01-01

    In research and practice, sentences or paragraphs of reading tests may be randomly chosen to assess reading performance. This means that in addition to test reliability, all sentences or paragraphs should be reliable and equally difficult to read. The sentences and paragraphs of five (un-)

  3. Reliability and validity of the rey visual design learning test in primary school children

    NARCIS (Netherlands)

    Wilhelm, P.

    2004-01-01

    The Rey Visual Design Learning Test (Rey, 1964, in Spreen & Strauss, 1991) assesses immediate memory span, new learning and recognition for non-verbal material. Three studies are presented that focused on the reliability and validity of the RVDLT in primary school children. Test-retest reliability

  4. Engineered Barrier System Thermal-Hydraulic-Chemical Column Test Report

    International Nuclear Information System (INIS)

    W.E. Lowry

    2001-01-01

    The Engineered Barrier System (EBS) Thermal-Hydraulic-Chemical (THC) Column Tests provide data needed for model validation. The EBS Degradation, Flow, and Transport Process Modeling Report (PMR) will be based on supporting models for in-drift THC coupled processes, and the in-drift physical and chemical environment. These models describe the complex chemical interaction of EBS materials, including granular materials, with the thermal and hydrologic conditions that will be present in the repository emplacement drifts. Of particular interest are the coupled processes that result in mineral and salt dissolution/precipitation in the EBS environment. Test data are needed for thermal, hydrologic, and geochemical model validation and to support selection of introduced materials (CRWMS M and O 1999c). These column tests evaluated granular crushed tuff as potential invert ballast or backfill material, under accelerated thermal and hydrologic environments. The objectives of the THC column testing are to: (1) Characterize THC coupled processes that could affect performance of EBS components, particularly the magnitude of permeability reduction (increases or decreases), the nature of minerals produced, and chemical fractionation (i.e., concentrative separation of salts and minerals due to boiling-point elevation). (2) Generate data for validating THC predictive models that will support the EBS Degradation, Flow, and Transport PMR, Rev. 01

  5. Test-Retest Reliability of Diffusion Tensor Imaging in Huntington's Disease.

    Science.gov (United States)

    Cole, James H; Farmer, Ruth E; Rees, Elin M; Johnson, Hans J; Frost, Chris; Scahill, Rachael I; Hobbs, Nicola Z

    2014-03-21

    Diffusion tensor imaging (DTI) has shown microstructural abnormalities in patients with Huntington's Disease (HD) and work is underway to characterise how these abnormalities change with disease progression. Using methods that will be applied in longitudinal research, we sought to establish the reliability of DTI in early HD patients and controls. Test-retest reliability, quantified using the intraclass correlation coefficient (ICC), was assessed using region-of-interest (ROI)-based white matter atlas and voxelwise approaches on repeat scan data from 22 participants (10 early HD, 12 controls). T1 data was used to generate further ROIs for analysis in a reduced sample of 18 participants. The results suggest that fractional anisotropy (FA) and other diffusivity metrics are generally highly reliable, with ICCs indicating considerably lower within-subject compared to between-subject variability in both HD patients and controls. Where ICC was low, particularly for the diffusivity measures in the caudate and putamen, this was partly influenced by outliers. The analysis suggests that the specific DTI methods used here are appropriate for cross-sectional research in HD, and give confidence that they can also be applied longitudinally, although this requires further investigation. An important caveat for DTI studies is that test-retest reliability may not be evenly distributed throughout the brain whereby highly anisotropic white matter regions tended to show lower relative within-subject variability than other white or grey matter regions.

  6. Validity and Reliability of the Clock Drawing Test in Older People

    Directory of Open Access Journals (Sweden)

    Massoumeh Sadeghipour Roodsari

    2013-07-01

    Full Text Available Objectives: Early diagnosis of cognitive disorders in order to initiate new efficient treatments in time is an important task which cannot be fulfilled without proper cognitive screening tools. The Clock Drawing Test (CDT is a simple inexpensive cognitive screening tool which can be used in primary care settings delivering health services to older people. The aim of this study was to assess validity and reliability of the CDT in Iranian older population. Methods & Materials: In this study the CDT and Mini Mental State Examination (MMSE were concurrently performed on 74 literate participants aged 60 and over. Participants were recruited from the clients of Iran Alzheimer’s Association (dementia patients and non-demented clients, including other patients or care givers during a 5 month period. The CDT was performed by two trained raters using Shulman’s six points scoring method. Using SPSS version 20, reliability was assessed measuring kappa statistics as well as ICC. Concurrent validity between CDT and MMSE were statistically analyzed by spearman’s rank correlation coefficient. Results: Mean age of the participants was 72 years in a range of 60 to 90 years with equal numbers 0f male and female participants. Kappa statistics for test retest reliability was 0.554 (P<0.001. ICC for inter rater reliability was 0.964 (P<0.001. Spearman’s rank correlation coefficient for MMSE and CDT scores was 0.782, statistically significant at P<0.001. Conclusion: CDT is a valid and reliable test in literate older people that can be used as a cognitive screening tool in Iranian older population.

  7. Reliability of lead-free solder joints with different PCB surface finishes under thermal cycling

    Energy Technology Data Exchange (ETDEWEB)

    Xia Yanghua [State Key Laboratory of Functional Materials for Informatics, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050 (China)], E-mail: xia_yanghua@hotmail.com; Xie Xiaoming [State Key Laboratory of Functional Materials for Informatics, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050 (China)

    2008-04-24

    The reliability of lead-free electronic assemblies under thermal cycling was investigated. Thin small outline package (TSOP) devices with FeNi leads were reflow soldered on FR4 PCB (printed circuit board) with Sn3.0Ag0.5Cu (wt%) solder. The effects of different PCB finishes (organic solderability preservative (OSP) and electroless nickel immersion gold (ENIG)) were studied. The results show that OSP finish reveals better performance than its ENIG counterparts. The crack originates at the fringe of heel fillet in both cases. The propagation of crack in the ENIG case is along the device/solder interface, while in the case of OSP, the crack extends parallel to the solder/PCB interface. When the OSP finishes are employed, many Cu6Sn5 precipitates form inside the bulk solder and have a strengthening effect on the solder joint, resulting in better reliability performance as compared to those with ENIG finishes.

  8. Reliability and smallest real difference of the ankle lunge test post ankle fracture.

    Science.gov (United States)

    Simondson, David; Brock, Kim; Cotton, Susan

    2012-02-01

    This study aimed to determine the reliability and the smallest real difference of the Ankle Lunge test in an ankle fracture patient population. In the post immobilisation stage of ankle fracture, ankle dorsiflexion is an important measure of progress and outcome. The Ankle Lunge test measures weight bearing dorsiflexion, resulting in negative scores (knee to wall distance) and positive scores (toe to wall distance), for which the latter has proven reliability in normal subjects only. A consecutive sample of ankle fracture patients with permission to commence weight bearing, were recruited to the study. Three measurements of the Ankle Lunge Test were performed each by two raters, one senior and one junior physiotherapist. These occurred prior to therapy sessions in the second week after plaster removal. A standardised testing station was utilised and allowed for both knee to wall distance and toe to wall distance measurement. Data was collected from 10 individuals with ankle fracture, with an average age of 36 years (SD 14.8). Seventy seven percent of observations were negative. Intra and inter-rater reliability yielded intra class correlations at or above 0.97, p Ankle Lunge test is a practical and reliable tool for measuring weightbearing dorsiflexion post ankle fracture. Copyright © 2011 Elsevier Ltd. All rights reserved.

  9. Reliability Evaluation of Primary Cells | Anyaka | Nigerian Journal of ...

    African Journals Online (AJOL)

    Evaluation of the reliability of a primary cell took place in three stages: 192 cells went through a slow-discharged test. A designed experiment was conducted on 144 cells; there were three factors in the experiment: Storage temperature (three levels), thermal shock (two levels) and date code (two levels). 16 cells ...

  10. Assembly reliability of CSPs with various chiip sizes by accelerated thermal and mechanical cycling test

    Science.gov (United States)

    Ghaffarian, R.

    2000-01-01

    A JPL-led chip scale package (CSP) Consortium, composed of team members representing government agencies and private companies, recently joined together to pool in-kind resources for developing the quality and reliability of chip scale packages (CSPs) for a variety of projects.

  11. Reliability of the "Ten Test" for assessment of discriminative sensation in hand trauma.

    Science.gov (United States)

    Berger, Michael J; Regan, William R; Seal, Alex; Bristol, Sean G

    2016-10-01

    "Ten Test" (TT) is a bedside measure of discriminative sensation, whereby the magnitude of abnormal sensation to moving light touch is normalized to an area of normal sensation on an 11-point Likert scale (0-10). The purposes of this study were to determine reliability parameters of the TT in a cohort of patients presenting to a hand trauma clinic with subjectively altered sensation post-injury and to compare the reliability of TT to that of the Weinstein Enhanced Sensory Test (WEST). Study participants (n = 29, mean age = 37 ± 12) comprised patients presenting to an outpatient hand trauma clinic with recent hand trauma and self reported abnormal sensation. Participants underwent TT and WEST by two separate raters on the same day. Interrater reliability, response stability and responsiveness of each test were determined by the intraclass correlation coefficient (ICC: 2, 1), standard error of measurement (SEM) with 95% confidence intervals (CI) and minimal detectable difference score, with 95% CI (MDD95), respectively. The TT displayed excellent interrater reliability (ICC = 0.95, 95% CI 0.89-0.97) compared to good reliability for WEST (ICC = 0.78, 95% CI 0.58-0.89). The range of true scores expected with 95% confidence based on the SEM (i.e. response stability), was ±1.1 for TT and ±1.1 for WEST. MDD95 scores reflecting test responsiveness were 1.5 and 1.6 for TT and WEST, respectively. The TT displayed excellent reliability parameters in this patient population. Reliability parameters were stronger for TT compared to WEST. These results provide support for the use of TT as a component of the sensory exam in hand trauma. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  12. Test-Retest Reliability of a Survey to Measure Transport-Related Physical Activity in Adults

    Science.gov (United States)

    Badland, Hannah; Schofield, Grant

    2006-01-01

    The present research details test-retest reliability of a newly developed, telephone-administered TPA survey for adults. This instrument examines barriers, perceptions, and current travel behaviors to place of work/study and local convenience shops. Demonstrated test-retest reliability of the Active Friendly Environments-Transport-Related Physical…

  13. A REVIEW OF SINGLE SPECIES TOXICITY TESTS: ARE THE TESTS RELIABLE PREDICTORS OF AQUATIC ECOSYSTEM COMMUNITY RESPONSES?

    Science.gov (United States)

    This document provides a comprehensive review to evaluate the reliability of indicator species toxicity test results in predicting aquatic ecosystem impacts, also called the ecological relevance of laboratory single species toxicity tests.

  14. The Functional Test for Agility Performance is a Reliable Quick Decision-Making Test for Skilled Water Polo Players

    Directory of Open Access Journals (Sweden)

    Tucher Guilherme

    2015-06-01

    Full Text Available The reliability of the Functional Test for Agility Performance has only been evaluated in water polo players in a small group of novice athletes. Thus, the aim of this study was to evaluate the reliability of the Functional Test for Agility Performance in skilled water polo players. Forty-two athletes (17.81 ± 3.24 years old with a minimum of 5 years of competitive experience (7.05 ± 2.84 years and playing at the national or international level were evaluated. The Functional Test for Agility Performance is characterized as a specific open decision-making test where a tested player moves as quickly as possible in accordance to a pass made by another player. The time spent in the test was measured by two experienced coaches. Descriptive statistics, repeated measures analysis of variance (ANOVA, 95% limit of agreement (LOA, intraclass correlation coefficient (ICC and standard error of measurements (SEM were used for data analysis. Athletes completed the Functional Test for Agility Performance in 4.15 0.47 s. The ICC value was 0.87 (95% IC = 0.80-0.92. The SEM varied between 0.24 and 0.38 s. The LOA was 1.20 s and the CV average considering each individual trial was 6%. The Functional Test for Agility Performance was shown to be a reliable quick decision-making test for skilled water polo players.

  15. Ground test facilities for evaluating nuclear thermal propulsion engines and fuel elements

    International Nuclear Information System (INIS)

    Allen, G.C.; Beck, D.F.; Harmon, C.D.; Shipers, L.R.

    1992-01-01

    Interagency panels evaluating nuclear thermal propulsion development options have consistently recognized the need for constructing a major new ground test facility to support fuel element and engine testing. This paper summarizes the requirements, configuration, and design issues of a proposed ground test complex for evaluating nuclear thermal propulsion engines and fuel elements being developed for the Space Nuclear Thermal Propulsion (SNTP) program. 2 refs

  16. Numerical modeling of Thermal Response Tests in Energy Piles

    Science.gov (United States)

    Franco, A.; Toledo, M.; Moffat, R.; Herrera, P. A.

    2013-05-01

    Nowadays, thermal response tests (TRT) are used as the main tools for the evaluation of low enthalpy geothermal systems such as heat exchangers. The results of TRT are used for estimating thermal conductivity and thermal resistance values of those systems. We present results of synthetic TRT simulations that model the behavior observed in an experimental energy pile system, which was installed at the new building of the Faculty of Engineering of Universidad de Chile. Moreover, we also present a parametric study to identify the most influent parameters in the performance of this type of tests. The modeling was developed using the finite element software COMSOL Multiphysics, which allows the incorporation of flow and heat transport processes. The modeled system consists on a concrete pile with 1 m diameter and 28 m deep, which contains a 28 mm diameter PEX pipe arranged in a closed circuit. Three configurations were analyzed: a U pipe, a triple U and a helicoid shape implemented at the experimental site. All simulations were run considering transient response in a three-dimensional domain. The simulation results provided the temperature distribution on the pile for a set of different geometry and physical properties of the materials. These results were compared with analytical solutions which are commonly used to interpret TRT data. This analysis demonstrated that there are several parameters that affect the system response in a synthetic TRT. For example, the diameter of the simulated pile affects the estimated effective thermal conductivity of the system. Moreover, the simulation results show that the estimated thermal conductivity for a 1 m diameter pile did not stabilize even after 100 hours since the beginning of the test, when it reached a value 30% below value used to set up the material properties in the simulation. Furthermore, we observed different behaviors depending on the thermal properties of concrete and soil. According to the simulations, the thermal

  17. Thermal Vacuum Test Correlation of a Zero Propellant Load Case Thermal Capacitance Propellant Gauging Analytical Model

    Science.gov (United States)

    Mckim, Stephen A.

    2016-01-01

    This thesis describes the development and correlation of a thermal model that forms the foundation of a thermal capacitance spacecraft propellant load estimator. Specific details of creating the thermal model for the diaphragm propellant tank used on NASA's Magnetospheric Multiscale spacecraft using ANSYS and the correlation process implemented are presented. The thermal model was correlated to within plus or minus 3 degrees Celsius of the thermal vacuum test data, and was determined sufficient to make future propellant predictions on MMS. The model was also found to be relatively sensitive to uncertainties in applied heat flux and mass knowledge of the tank. More work is needed to improve temperature predictions in the upper hemisphere of the propellant tank where predictions were found to be 2 to 2.5 C lower than the test data. A road map for applying the model to predict propellant loads on the actual MMS spacecraft toward its end of life in 2017-2018 is also presented.

  18. Effects of Differential Item Functioning on Examinees' Test Performance and Reliability of Test

    Science.gov (United States)

    Lee, Yi-Hsuan; Zhang, Jinming

    2017-01-01

    Simulations were conducted to examine the effect of differential item functioning (DIF) on measurement consequences such as total scores, item response theory (IRT) ability estimates, and test reliability in terms of the ratio of true-score variance to observed-score variance and the standard error of estimation for the IRT ability parameter. The…

  19. Reliability of externally fixed dynamometry hamstring strength testing in elite youth football players.

    Science.gov (United States)

    Wollin, Martin; Purdam, Craig; Drew, Michael K

    2016-01-01

    To investigate inter and intra-tester reliability of an externally fixed dynamometry unilateral hamstring strength test, in the elite sports setting. Reliability study. Sixteen, injury-free, elite male youth football players (age=16.81±0.54 years, height=180.22±5.29cm, weight 73.88±6.54kg, BMI=22.57±1.42) gave written informed consent. Unilateral maximum isometric peak hamstring force was evaluated by externally fixed dynamometry for inter-tester, intra-day and intra-tester, inter-week reliability. The test position was standardised to correlate with the terminal swing phase of the gait running cycle. Inter and intra-tester values demonstrated good to high levels of reliability. The intra-class coefficient (ICC) for inter-tester, intra-day reliability was 0.87 (95% CI=0.75-0.93) with standard error of measure percentage (SEM%) 4.7 and minimal detectable change percentage (MDC%) 12.9. Intra-tester, inter-week reliability results were ICC 0.86 (95% CI, 0.74-0.93), SEM% 5.0 and MDC% 14.0. This study demonstrates good to high inter and intra-tester reliability of isometric externally fixed dynamometry unilateral hamstring strength testing in the regular elite sport setting involving elite male youth football players. The intra-class coefficient in association with the low standard error of measure and minimal detectable change percentages suggest that this procedure is appropriate for clinical and academic use as well as monitoring hamstring strength in the elite sport setting. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  20. Thermal Testing and Model Correlation of the Magnetospheric Multiscale (MMS) Observatories

    Science.gov (United States)

    Kim, Jong S.; Teti, Nicholas M.

    2015-01-01

    The Magnetospheric Multiscale (MMS) mission is a Solar Terrestrial Probes mission comprising four identically instrumented spacecraft that will use Earth's magnetosphere as a laboratory to study the microphysics of three fundamental plasma processes: magnetic reconnection, energetic particle acceleration, and turbulence. This paper presents the complete thermal balance (TB) test performed on the first of four observatories to go through thermal vacuum (TV) and the minibalance testing that was performed on the subsequent observatories to provide a comparison of all four. The TV and TB tests were conducted in a thermal vacuum chamber at the Naval Research Laboratory (NRL) in Washington, D.C. with the vacuum level higher than 1.3 x 10 (sup -4) pascals (10 (sup -6) torr) and the surrounding temperature achieving -180 degrees Centigrade. Three TB test cases were performed that included hot operational science, cold operational science and a cold survival case. In addition to the three balance cases a two hour eclipse and a four hour eclipse simulation was performed during the TV test to provide additional transient data points that represent the orbit in eclipse (or Earth's shadow) The goal was to perform testing such that the flight orbital environments could be simulated as closely as possible. A thermal model correlation between the thermal analysis and the test results was completed. Over 400 1-Wire temperature sensors, 200 thermocouples and 125 flight thermistor temperature sensors recorded data during TV and TB testing. These temperature versus time profiles and their agreements with the analytical results obtained using Thermal Desktop and SINDA/FLUINT are discussed. The model correlation for the thermal mathematical model (TMM) is conducted based on the numerical analysis results and the test data. The philosophy of model correlation was to correlate the model to within 3 degrees Centigrade of the test data using the standard deviation and mean deviation error

  1. A Temperature-Dependent Thermal Model of IGBT Modules Suitable for Circuit-Level Simulations

    DEFF Research Database (Denmark)

    Wu, Rui; Wang, Huai; Ma, Ke

    2014-01-01

    Thermal impedance of IGBT modules may vary with operating conditions due to that the thermal conductivity and heat capacity of materials are temperature dependent. This paper proposes a Cauer thermal model for a 1700 V/1000 A IGBT module with temperature-dependent thermal resistances and thermal ...... relevant reliability aspect performance. A test bench is built up with an ultra-fast infrared (IR) camera to validate the proposed thermal impedance model....

  2. Steam generator thermal hydraulic design & functional architecture features and related operational and reliability issues requiring consideration

    International Nuclear Information System (INIS)

    Klarner, R.G.

    2012-01-01

    Proper thermal hydraulic design and functional architecture are critical to successful steam generator operation and long term reliability. The evolution of steam generators has been a gradual learning process that has benefited from continuous industry operational experience (OPEX). Inadequate thermal hydraulic design can lead to numerous degradation mechanisms such as excessive deposition, corrosion, flow and level instabilities, fluid-elastic instabilities and tube wear. The functional architecture determines the health of the tube bundle and the other internals during manufacturing, handling and operation. It also determines thermal performance as well as establishing global thermal-hydraulic characteristics such as water level shrink and swell response. This paper discusses the range of operational and reliability issues and relates them to the thermal hydraulic attributes and functional architecture of steam generators (many SG reliability issues are further discussed in other presentations at this conference). In pursuing such issues, the paper focuses on the four major features of the equipment, identifying in each case the goals and requirements such features must meet. Typical approaches and the means by which such requirements are addressed in current equipment are discussed. The four features are: 1. Tubing Material and Tube Bundle Heat Transfer Performance; a. Two materials are in current use – Alloy 690 TT and Alloy 800. Both are good materials with excellent performance records which serve their owners very well (the reliability attributes of Alloy 800 and 690 are discussed in other papers at this conference). Caution is advised in the supply of any material: – material quality is only assured by what is specified to material suppliers in procurement specifications – i.e. - all the knowledge and research in the world assures nothing if its findings are not reflected in procurement requirements. b. Heat transfer performance in addition to being

  3. Gearbox Reliability Collaborative Phase 3 Gearbox 3 Test Plan

    Energy Technology Data Exchange (ETDEWEB)

    Keller, Jonathan [National Renewable Energy Lab. (NREL), Golden, CO (United States); Wallen, Robb [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-10-01

    This document describes the Phase 3 test plan for the Gearbox Reliability Collaborative Gearbox #3. The primary test objective is to measure the planetary load sharing characteristics in the same conditions as the original gearbox design. If the measured load-sharing characteristics are close to the design model, the projected three-times improvement in planetary section predicted fatigue life and the efficacy of preloaded tapered roller bearings in mitigating the planetary bearing fatigue failure mode will have been demonstrated.

  4. Statistical Considerations in Choosing a Test Reliability Coefficient. ACT Research Report Series, 2012 (10)

    Science.gov (United States)

    Woodruff, David; Wu, Yi-Fang

    2012-01-01

    The purpose of this paper is to illustrate alpha's robustness and usefulness, using actual and simulated educational test data. The sampling properties of alpha are compared with the sampling properties of several other reliability coefficients: Guttman's lambda[subscript 2], lambda[subscript 4], and lambda[subscript 6]; test-retest reliability;…

  5. Reliability Engineering

    International Nuclear Information System (INIS)

    Lee, Sang Yong

    1992-07-01

    This book is about reliability engineering, which describes definition and importance of reliability, development of reliability engineering, failure rate and failure probability density function about types of it, CFR and index distribution, IFR and normal distribution and Weibull distribution, maintainability and movability, reliability test and reliability assumption in index distribution type, normal distribution type and Weibull distribution type, reliability sampling test, reliability of system, design of reliability and functionality failure analysis by FTA.

  6. Reliability of candida skin test in the evaluation of T-cell function in ...

    African Journals Online (AJOL)

    Ehab

    2017-01-23

    Jan 23, 2017 ... considered generally reliable under the age of 1 year.6 ... We sought to investigate the reliability of manually ... Conclusion: Candida intradermal test is a cost- effective ..... Ballow M. Historical perspectives in the diagnosis.

  7. Test program for NIS calibration to reactor thermal output in HTTR

    International Nuclear Information System (INIS)

    Nakagawa, Shigeaki; Shinozaki, Masayuki; Tachibana, Yukio; Kunitomi, Kazuhiko

    2000-03-01

    Rise-to-power test program for reactor thermal output measurement has been established to calibrate a neutron instrumentation system taking account of the characteristics of the High Temperature Engineering Test Reactor (HTTR). An error of reactor thermal output measurement was evaluated taking account of a configuration of instrumentation system. And the expected dispersion of measurement in the full power operation was evaluated from non-nuclear heat-up of primary coolant up to 213degC. From the evaluation, it was found that an error of reactor thermal output measurement would be less than ±2.0% at the rated power. This report presents the detailed program of rise-to-power test for reactor thermal output measurement and discusses its measurement error. (author)

  8. Test-retest reliability of jump execution variables using mechanography: a comparison of jump protocols.

    Science.gov (United States)

    Fitzgerald, John S; Johnson, LuAnn; Tomkinson, Grant; Stein, Jesse; Roemmich, James N

    2018-05-01

    Mechanography during the vertical jump may enhance screening and determining mechanistic causes underlying physical performance changes. Utility of jump mechanography for evaluation is limited by scant test-retest reliability data on force-time variables. This study examined the test-retest reliability of eight jump execution variables assessed from mechanography. Thirty-two women (mean±SD: age 20.8 ± 1.3 yr) and 16 men (age 22.1 ± 1.9 yr) attended a familiarization session and two testing sessions, all one week apart. Participants performed two variations of the squat jump with squat depth self-selected and controlled using a goniometer to 80º knee flexion. Test-retest reliability was quantified as the systematic error (using effect size between jumps), random error (using coefficients of variation), and test-retest correlations (using intra-class correlation coefficients). Overall, jump execution variables demonstrated acceptable reliability, evidenced by small systematic errors (mean±95%CI: 0.2 ± 0.07), moderate random errors (mean±95%CI: 17.8 ± 3.7%), and very strong test-retest correlations (range: 0.73-0.97). Differences in random errors between controlled and self-selected protocols were negligible (mean±95%CI: 1.3 ± 2.3%). Jump execution variables demonstrated acceptable reliability, with no meaningful differences between the controlled and self-selected jump protocols. To simplify testing, a self-selected jump protocol can be used to assess force-time variables with negligible impact on measurement error.

  9. Reliability assessment for metallized film pulse capacitors with accelerated degradation test

    International Nuclear Information System (INIS)

    Zhao Jianyin; Liu Fang; Xi Wenjun; He Shaobo; Wei Xiaofeng

    2011-01-01

    The high energy density self-healing metallized film pulse capacitor has been applied to all kinds of laser facilities for their power conditioning systems, whose reliability is straightforward affected by the reliability level of capacitors. Reliability analysis of highly reliable devices, such as metallized film capacitors, is a challenge due to cost and time restriction. Accelerated degradation test provides a way to predict its life cost and time effectively. A model and analyses for accelerated degradation data of metallized film capacitors are described. Also described is a method for estimating the distribution of failure time. The estimation values of the unknown parameters in this model are 9.066 9 x 10 -8 and 0.022 1. Both the failure probability density function (PDF) and the cumulative distribution function (CDF) can be presented by this degradation failure model. Based on these estimation values and the PDF/CDF, the reliability model of the metallized film capacitors is obtained. According to the reliability model, the probability of the capacitors surviving to 20 000 shot is 0.972 4. (authors)

  10. Reliability of a Test Battery Designed for Quickly and Safely Assessing Diverse Indices of Neuromuscular Function

    Science.gov (United States)

    Spiering, Barry A.; Lee, Stuart M. C.; Mulavara, Ajitkumar P.; Bentley, Jason, R.; Buxton, Roxanne E.; Lawrence, Emily L.; Sinka, Joseph; Guilliams, Mark E.; Ploutz-Snyder, Lori L.; Bloomberg, Jacob J.

    2010-01-01

    Spaceflight affects nearly every physiological system. Spaceflight-induced alterations in physiological function translate to decrements in functional performance. Purpose: To develop a test battery for quickly and safely assessing diverse indices of neuromuscular performance. I. Quickly: Battery of tests can be completed in approx.30-40 min. II. Safely: a) No eccentric muscle actions or impact forces. b) Tests present little challenge to postural stability. III. Diverse indices: a) Strength: Excellent reliability (ICC = 0.99) b) Central activation: Very good reliability (ICC = 0.87) c) Power: Excellent reliability (ICC = 0.99) d) Endurance: Total work has excellent reliability (ICC = 0.99) e) Force steadiness: Poor reliability (ICC = 0.20 - 0.60) National

  11. Accelerated Thermal Cycling Test of Microencapsulated Paraffin Wax/Polyaniline Made by Simple Preparation Method for Solar Thermal Energy Storage.

    Science.gov (United States)

    Silakhori, Mahyar; Naghavi, Mohammad Sajad; Metselaar, Hendrik Simon Cornelis; Mahlia, Teuku Meurah Indra; Fauzi, Hadi; Mehrali, Mohammad

    2013-04-29

    Microencapsulated paraffin wax/polyaniline was prepared using a simple in situ polymerization technique, and its performance characteristics were investigated. Weight losses of samples were determined by Thermal Gravimetry Analysis (TGA). The microencapsulated samples with 23% and 49% paraffin showed less decomposition after 330 °C than with higher percentage of paraffin. These samples were then subjected to a thermal cycling test. Thermal properties of microencapsulated paraffin wax were evaluated by Differential Scanning Calorimeter (DSC). Structure stability and compatibility of core and coating materials were also tested by Fourier transform infrared spectrophotometer (FTIR), and the surface morphology of the samples are shown by Field Emission Scanning Electron Microscopy (FESEM). It has been found that the microencapsulated paraffin waxes show little change in the latent heat of fusion and melting temperature after one thousand thermal recycles. Besides, the chemical characteristics and structural profile remained constant after one thousand thermal cycling tests. Therefore, microencapsulated paraffin wax/polyaniline is a stable material that can be used for thermal energy storage systems.

  12. Reliability testing of the Danish version of the Kidney Disease Quality of Life Short Form

    DEFF Research Database (Denmark)

    Molsted, Stig; Heaf, James; Prescott, Lotte

    2005-01-01

    . MATERIAL AND METHODS: Translation into Danish and back-translation into English were performed. Pilot, field and internal consistency reliability tests were performed. RESULTS: Cronbach's alpha coefficients for the internal reliability test ranged from 0.77 to 0.93 for the eight generic scales. In a test......OBJECTIVE: The questionnaire Kidney Disease Quality of Life Short Form version 1.3 (KDQOL-SF) is valuable for assessing the health-related quality of life in patients treated with chronic dialysis. The aim of this study was to translate and test the reliability of the KDQOL-SF for use in Denmark...... involving all patients, two of the disease-specific scales had Cronbach's alpha coefficients of test of the scores...

  13. Thermal Fatigue Evaluation of Pb-Free Solder Joints: Results, Lessons Learned, and Future Trends

    Science.gov (United States)

    Coyle, Richard J.; Sweatman, Keith; Arfaei, Babak

    2015-09-01

    Thermal fatigue is a major source of failure of solder joints in surface mount electronic components and it is critically important in high reliability applications such as telecommunication, military, and aeronautics. The electronic packaging industry has seen an increase in the number of Pb-free solder alloy choices beyond the common near-eutectic Sn-Ag-Cu alloys first established as replacements for eutectic SnPb. This paper discusses the results from Pb-free solder joint reliability programs sponsored by two industry consortia. The characteristic life in accelerated thermal cycling is reported for 12 different Pb-free solder alloys and a SnPb control in 9 different accelerated thermal cycling test profiles in terms of the effects of component type, accelerated thermal cycling profile and dwell time. Microstructural analysis on assembled and failed samples was performed to investigate the effect of initial microstructure and its evolution during accelerated thermal cycling test. A significant finding from the study is that the beneficial effect of Ag on accelerated thermal cycling reliability (measured by characteristic lifetime) diminishes as the severity of the accelerated thermal cycling, defined by greater ΔT, higher peak temperature, and longer dwell time increases. The results also indicate that all the Pb-free solders are more reliable in accelerated thermal cycling than the SnPb alloy they have replaced. Suggestions are made for future work, particularly with respect to the continued evolution of alloy development for emerging application requirements and the value of using advanced analytical methods to provide a better understanding of the effect of microstructure and its evolution on accelerated thermal cycling performance.

  14. Facility for endurance tests of thermal insulations

    International Nuclear Information System (INIS)

    Mauersberger, R.

    1984-01-01

    In the following report the design and construction of an experimental facility for endurance tests of thermal insulations is presented. It's name in abbreviation is 'ADI' standing for the German words A nlage zum Dauertest von Isolierungen . This test facility was build by HRB in order to investigate the performance of thermal insulation systems of hot gas ducts for the process heat-reactor-project. The tests are intended to simulate the conditions of reactor operation. They include short-time experiments for selection of insulation-concepts and in a second step long-time experiments as performance tests. During these tests are measured the effective heat conductivity the local heat losses the temperature profiles of the insulation, of the fixing elements and along the wall of the duct. The design-data required to perform all these tasks are shown in the first picture: The gas-atmosphere must be Helium in tests like in reactor with regard to the special thermal and hydraulic properties of Helium and to the influence of Helium on mechanic friction and wear. The hot gas temperature in the PNP-reactor will be 950 deg. C and should be equal in the experiments. The temperature on the cold side of the insulation has to be adjustable from 50 deg. C up to 300 deg. C. The Helium pressure in the hot gas ducts of a HTR-plant is about 42 bar. The ADI was laid out for 70 bar to cover the hole range of interest. A Helium mass flow has to stream through the insulated test duct in order to realize equal temperatures on the hot side of the insulation. A flow rate of 4,5 kg/s is sufficient for this requirement. The axial pressure gradient along the insulation must be the same as in the reactor, because this has an essential influence on the heat losses. This pressure gradient is about 40 Pa/m

  15. The minimum sit-to-stand height test: reliability, responsiveness and relationship to leg muscle strength.

    Science.gov (United States)

    Schurr, Karl; Sherrington, Catherine; Wallbank, Geraldine; Pamphlett, Patricia; Olivetti, Lynette

    2012-07-01

    To determine the reliability of the minimum sit-to-stand height test, its responsiveness and its relationship to leg muscle strength among rehabilitation unit inpatients and outpatients. Reliability study using two measurers and two test occasions. Secondary analysis of data from two clinical trials. Inpatient and outpatient rehabilitation services in three public hospitals. Eighteen hospital patients and five others participated in the reliability study. Seventy-two rehabilitation unit inpatients and 80 outpatients participated in the clinical trials. The minimum sit-to-stand height test was assessed using a standard procedure. For the reliability study, a second tester repeated the minimum sit-to-stand height test on the same day. In the inpatient clinical trial the measures were repeated two weeks later. In the outpatient trial the measures were repeated five weeks later. Knee extensor muscle strength was assessed in the clinical trials using a hand-held dynamometer. The reliability for the minimum sit-to-stand height test was excellent (intraclass correlation coefficient (ICC) 0.91, 95% confidence interval (CI) 0.81-0.96). The standard error of measurement was 34 mm. Responsiveness was moderate in the inpatient trial (effect size: 0.53) but small in the outpatient trial (effect size: 0.16). A small proportion (8-17%) of variability in minimum sit-to-stand height test was explained by knee extensor muscle strength. The minimum sit-to-stand height test has excellent reliability and moderate responsiveness in an inpatient rehabilitation setting. Responsiveness in an outpatient rehabilitation setting requires further investigation. Performance is influenced by factors other than knee extensor muscle strength.

  16. Thermal-hydraulic tests on net divertor targets using swirl tubes

    International Nuclear Information System (INIS)

    Schlosser, J.; Chappuis, P.; Deschamps, P.; Massmann, P.; Falter, H.D.; Deschamps, G.H.

    1991-01-01

    Thermal-hydraulic tests have been carried out in collaboration between NET, CEA Cadarache and JET in order to find a cooling method capable of removing the high heat fluxes expected for the NET/ITER divertor. The goal was to evaluate by experiments the critical heat flux (CHF) and heat transfer in the subcooled boiling regime using twisted tapes as turbulence promoters and testing them under relevant thermal-hydraulic conditions. The CEA 200 kW Electron Beam (EB) facility and the 10 MW JET Neutral Beam (NB) test bed have been used to heat up the NET relevant test sections (TS) consisting of rectangular copper elements with circular internal channels. The TS have been exposed to the electron or ion beams under normal incidence. This paper reports the results of the experiments and of thermal analyses performed in support of the tests. The experimental CHF values have been benchmarked with the Tong-75 correlation

  17. Use of thermal sieve to allow optical testing of cryogenic optical systems.

    Science.gov (United States)

    Kim, Dae Wook; Cai, Wenrui; Burge, James H

    2012-05-21

    Full aperture testing of large cryogenic optical systems has been impractical due to the difficulty of operating a large collimator at cryogenic temperatures. The Thermal Sieve solves this problem by acting as a thermal barrier between an ambient temperature collimator and the cryogenic system under test. The Thermal Sieve uses a set of thermally controlled baffles with array of holes that are lined up to pass the light from the collimator without degrading the wavefront, while attenuating the thermal background by nearly 4 orders of magnitude. This paper provides the theory behind the Thermal Sieve system, evaluates the optimization for its optical and thermal performance, and presents the design and analysis for a specific system.

  18. Reliability of Health-Related Physical Fitness Tests among Colombian Children and Adolescents: The FUPRECOL Study.

    Directory of Open Access Journals (Sweden)

    Robinson Ramírez-Vélez

    Full Text Available Substantial evidence indicates that youth physical fitness levels are an important marker of lifestyle and cardio-metabolic health profiles and predict future risk of chronic diseases. The reliability physical fitness tests have not been explored in Latino-American youth population. This study's aim was to examine the reliability of health-related physical fitness tests that were used in the Colombian health promotion "Fuprecol study". Participants were 229 Colombian youth (boys n = 124 and girls n = 105 aged 9 to 17.9 years old. Five components of health-related physical fitness were measured: 1 morphological component: height, weight, body mass index (BMI, waist circumference, triceps skinfold, subscapular skinfold, and body fat (% via impedance; 2 musculoskeletal component: handgrip and standing long jump test; 3 motor component: speed/agility test (4x10 m shuttle run; 4 flexibility component (hamstring and lumbar extensibility, sit-and-reach test; 5 cardiorespiratory component: 20-meter shuttle-run test (SRT to estimate maximal oxygen consumption. The tests were performed two times, 1 week apart on the same day of the week, except for the SRT which was performed only once. Intra-observer technical errors of measurement (TEMs and inter-rater (reliability were assessed in the morphological component. Reliability for the Musculoskeletal, motor and cardiorespiratory fitness components was examined using Bland-Altman tests. For the morphological component, TEMs were small and reliability was greater than 95% of all cases. For the musculoskeletal, motor, flexibility and cardiorespiratory components, we found adequate reliability patterns in terms of systematic errors (bias and random error (95% limits of agreement. When the fitness assessments were performed twice, the systematic error was nearly 0 for all tests, except for the sit and reach (mean difference: -1.03% [95% CI = -4.35% to -2.28%]. The results from this study indicate that the

  19. Reliability of thermal-hydraulic passive safety systems

    International Nuclear Information System (INIS)

    D'Auria, F.; Araneo, D.; Pierro, F.; Galassi, G.

    2014-01-01

    The scholar will be informed of reliability concepts applied to passive system adopted for nuclear reactors. Namely, for classical components and systems the failure concept is associated with malfunction of breaking of hardware. In the case of passive systems the failure is associated with phenomena. A method for studying the reliability of passive systems is discussed and is applied. The paper deals with the description of the REPAS (Reliability Evaluation of Passive Safety System) methodology developed by University of Pisa (UNIPI) and with results from its application. The general objective of the REPAS methodology is to characterize the performance of a passive system in order to increase the confidence toward its operation and to compare the performances of active and passive systems and the performances of different passive systems

  20. Thermal-Hydraulic Tests for Reactor Core Safety

    International Nuclear Information System (INIS)

    Chun, Se Young; Chung, Moon Ki; Baek, Won Pil and others

    2005-04-01

    The reflood experiments for single rod annulus geometry have been performed to investigate the effect of spacer grid on thermal-hydraulics under reflood conditions. The reflood experimental loop for 6x6 rod bundle with a spacer grid developed in Korea has been provided. About 8000 data points for Post-CHF heat transfer have been obtained from the experiments About 1400 CHF data points for 3x3 Water and 5x5 Freon rod bundles have been obtained. The existing evaluation methodology for core safety under return-to-power conditions has been investigated using KAERI low flow CHF database. The hydraulic tests for turbulence mixing characteristics in subchannel of 5x5 rod bundle have been carried out using advanced measurement technique, LVD and the database for various spacer grids have been provided. In order to measure the turbulence mixing characteristics in details, the hydraulic loop with a magnified 5x5 rod bundle has been prepared. The database which was constructed through a systematic thermal hydraulic tests for the reflood phenomenon, CHF, Post-CHF is surely to be useful to the industry field, the regulation body and the development of thermal-hydraulic analysis code

  1. Reliability and validity of a talent identification test battery for seated and standing Paralympic throws.

    Science.gov (United States)

    Spathis, Jemima Grace; Connick, Mark James; Beckman, Emma Maree; Newcombe, Peter Anthony; Tweedy, Sean Michael

    2015-01-01

    Paralympic throwing events for athletes with physical impairments comprise seated and standing javelin, shot put, discus and seated club throwing. Identification of talented throwers would enable prediction of future success and promote participation; however, a valid and reliable talent identification battery for Paralympic throwing has not been reported. This study evaluates the reliability and validity of a talent identification battery for Paralympic throws. Participants were non-disabled so that impairment would not confound analyses, and results would provide an indication of normative performance. Twenty-eight non-disabled participants (13 M; 15 F) aged 23.6 years (±5.44) performed five kinematically distinct criterion throws (three seated, two standing) and nine talent identification tests (three anthropometric, six motor); 23 were tested a second time to evaluate test-retest reliability. Talent identification test-retest reliability was evaluated using Intra-class Correlation Coefficient (ICC) and Bland-Altman plots (Limits of Agreement). Spearman's correlation assessed strength of association between criterion throws and talent identification tests. Reliability was generally acceptable (mean ICC = 0.89), but two seated talent identification tests require more extensive familiarisation. Correlation strength (mean rs = 0.76) indicated that the talent identification tests can be used to validly identify individuals with competitively advantageous attributes for each of the five kinematically distinct throwing activities. Results facilitate further research in this understudied area.

  2. NDT Reliability - Final Report. Reliability in non-destructive testing (NDT) of the canister components

    Energy Technology Data Exchange (ETDEWEB)

    Pavlovic, Mato; Takahashi, Kazunori; Mueller, Christina; Boehm, Rainer (BAM, Federal Inst. for Materials Research and Testing, Berlin (Germany)); Ronneteg, Ulf (Swedish Nuclear Fuel and Waste Management Co., Stockholm (Sweden))

    2008-12-15

    This report describes the methodology of the reliability investigation performed on the ultrasonic phased array NDT system, developed by SKB in collaboration with Posiva, for inspection of the canisters for permanent storage of nuclear spent fuel. The canister is composed of a cast iron insert surrounded by a copper shell. The shell is composed of the tube and the lid/base which are welded to the tube after the fuel has been place, in the tube. The manufacturing process of the canister parts and the welding process are described. Possible defects, which might arise in the canister components during the manufacturing or in the weld during the welding, are identified. The number of real defects in manufactured components have been limited. Therefore the reliability of the NDT system has been determined using a number of test objects with artificial defects. The reliability analysis is based on the signal response analysis. The conventional signal response analysis is adopted and further developed before applied on the modern ultrasonic phased-array NDT system. The concept of multi-parameter a, where the response of the NDT system is dependent on more than just one parameter, is introduced. The weakness of use of the peak signal response in the analysis is demonstrated and integration of the amplitudes in the C-scan is proposed as an alternative. The calculation of the volume POD, when the part is inspected with more configurations, is also presented. The reliability analysis is supported by the ultrasonic simulation based on the point source synthesis method

  3. RELIABILITY OF THE ONE REPETITION-MAXIMUM POWER CLEAN TEST IN ADOLESCENT ATHLETES

    Science.gov (United States)

    Faigenbaum, Avery D.; McFarland, James E.; Herman, Robert; Naclerio, Fernando; Ratamess, Nicholas A.; Kang, Jie; Myer, Gregory D.

    2013-01-01

    Although the power clean test is routinely used to assess strength and power performance in adult athletes, the reliability of this measure in younger populations has not been examined. Therefore, the purpose of this study was to determine the reliability of the one repetition maximum (1 RM) power clean in adolescent athletes. Thirty-six male athletes (age 15.9 ± 1.1 yrs, body mass 79.1 ± 20.3 kg, height 175.1 ±7.4 cm) who had more than 1 year of training experience with weightlifting exercises performed a 1 RM power clean on two nonconsecutive days in the afternoon following standardized procedures. All test procedures were supervised by a senior level weightlifting coach and consisted of a systematic progression in test load until the maximum resistance that could be lifted for one repetition using proper exercise technique was determined. Data were analyzed using an intraclass correlation coefficient (ICC [2,k]), Pearson correlation coefficient (r), repeated measures ANOVA, Bland-Altman plot, and typical error analyses. Analysis of the data revealed that the test measures were highly reliable demonstrating a test-retest ICC of 0.98 (95% CI = 0.96–0.99). Testing also demonstrated a strong relationship between 1 RM measures on trial 1 and trial 2 (r=0.98, pinjuries occurred during the study period and the testing protocol was well-tolerated by all subjects. These findings indicate that 1 RM power clean testing has a high degree of reproducibility in trained male adolescent athletes when standardized testing procedures are followed and qualified instruction is present. PMID:22233786

  4. Orthopaedic nurses' knowledge and interrater reliability of neurovascular assessments with 2-point discrimination test.

    Science.gov (United States)

    Turney, Jennifer; Raley Noble, Deana; Kim, Son Chae

    2013-01-01

    : This study was conducted to evaluate the effects of education on knowledge and interrater reliability of neurovascular assessments with 2-point discrimination (2-PD) test among pediatric orthopaedic nurses. : A pre- and posttest study was done among 60 nurses attending 2-hour educational sessions. Neurovascular assessments with 2-PD test were performed on 64 casted pediatric patients by the nurses and 5 nurse experts before and after the educational sessions. : The mean neurovascular assessment knowledge score was improved at posteducation compared with the preeducation (p < .001). The 2-PD test interrater reliability also improved from Cohen's kappa value of 0.24-0.48 at posteducation. : The 2-hour educational session may be effective in improving nurses' knowledge and the interrater reliability of neurovascular assessment with 2-PD test.

  5. Test-Retest Reliability and Minimal Detectable Change of the D2 Test of Attention in Patients with Schizophrenia.

    Science.gov (United States)

    Lee, Posen; Lu, Wen-Shian; Liu, Chin-Hsuan; Lin, Hung-Yu; Hsieh, Ching-Lin

    2017-12-08

    The d2 Test of Attention (D2) is a commonly used measure of selective attention for patients with schizophrenia. However, its test-retest reliability and minimal detectable change (MDC) are unknown in patients with schizophrenia, limiting its utility in both clinical and research settings. The aim of the present study was to examine the test-retest reliability and MDC of the D2 in patients with schizophrenia. A rater administered the D2 on 108 patients with schizophrenia twice at a 1-month interval. Test-retest reliability was determined through the calculation of the intra-class correlation coefficient (ICC). We also carried out Bland-Altman analysis, which included a scatter plot of the differences between test and retest against their mean. Systematic biases were evaluated by use of a paired t-test. The ICCs for the D2 ranged from 0.78 to 0.94. The MDCs (MDC%) of the seven subscores were 102.3 (29.7), 19.4 (85.0), 7.2 (94.6), 21.0 (69.0), 104.0 (33.1), 105.0 (35.8), and 7.8 (47.8), which represented limited-to-acceptable random measurement error. Trends in the Bland-Altman plots of the omissions (E1), commissions (E2), and errors (E) were noted, presenting that the data had heteroscedasticity. According to the results, the D2 had good test-retest reliability, especially in the scores of TN, TN-E, and CP. For the further research, finding a way to improve the administration procedure to reduce random measurement error would be important for the E1, E2, E, and FR subscores. © The Author(s) 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  6. Note: An online testing method for lifetime projection of high power light-emitting diode under accelerated reliability test.

    Science.gov (United States)

    Chen, Qi; Chen, Quan; Luo, Xiaobing

    2014-09-01

    In recent years, due to the fast development of high power light-emitting diode (LED), its lifetime prediction and assessment have become a crucial issue. Although the in situ measurement has been widely used for reliability testing in laser diode community, it has not been applied commonly in LED community. In this paper, an online testing method for LED life projection under accelerated reliability test was proposed and the prototype was built. The optical parametric data were collected. The systematic error and the measuring uncertainty were calculated to be within 0.2% and within 2%, respectively. With this online testing method, experimental data can be acquired continuously and sufficient amount of data can be gathered. Thus, the projection fitting accuracy can be improved (r(2) = 0.954) and testing duration can be shortened.

  7. Intra and Inter-Rater Reliability of Screening for Movement Impairments: Movement Control Tests from The Foundation Matrix

    Science.gov (United States)

    Mischiati, Carolina R.; Comerford, Mark; Gosford, Emma; Swart, Jacqueline; Ewings, Sean; Botha, Nadine; Stokes, Maria; Mottram, Sarah L.

    2015-01-01

    Pre-season screening is well established within the sporting arena, and aims to enhance performance and reduce injury risk. With the increasing need to identify potential injury with greater accuracy, a new risk assessment process has been produced; The Performance Matrix (battery of movement control tests). As with any new method of objective testing, it is fundamental to establish whether the same results can be reproduced between examiners and by the same examiner on consecutive occasions. This study aimed to determine the intra-rater test re-test and inter-rater reliability of tests from a component of The Performance Matrix, The Foundation Matrix. Twenty participants were screened by two experienced musculoskeletal therapists using nine tests to assess the ability to control movement during specific tasks. Movement evaluation criteria for each test were rated as pass or fail. The therapists observed participants real-time and tests were recorded on video to enable repeated ratings four months later to examine intra-rater reliability (videos rated two weeks apart). Overall test percentage agreement was 87% for inter-rater reliability; 98% Rater 1, 94% Rater 2 for test re-test reliability; and 75% for real-time versus video. Intraclass-correlation coefficients (ICCs) were excellent between raters (0.81) and within raters (Rater 1, 0.96; Rater 2, 0.88) but poor for real-time versus video (0.23). Reliability for individual components of each test was more variable: inter-rater, 68-100%; intra-rater, 88-100% Rater 1, 75-100% Rater 2; and real-time versus video 31-100%. Cohen’s Kappa values for inter-rater reliability were 0.0-1.0; intra-rater 0.6-1.0 for Rater 1; -0.1-1.0 for Rater 2; and -0.1-1 for real-time versus video. It is concluded that both inter and intra-rater reliability of tests in The Foundation Matrix are acceptable when rated by experienced therapists. Recommendations are made for modifying some of the criteria to improve reliability where

  8. 75 FR 50853 - Special Conditions: Cirrus Design Corporation Model SF50 Airplane; Function and Reliability Testing

    Science.gov (United States)

    2010-08-18

    ... airplanes. 1. Function and Reliability Testing. Flight tests: In place of 14 CFR 21.35(b)(2), the following...; Function and Reliability Testing AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Final special... to CAR part 3 became effective January 15, 1951, and deleted the service test requirements in Section...

  9. Digital System Reliability Test for the Evaluation of safety Critical Software of Digital Reactor Protection System

    Directory of Open Access Journals (Sweden)

    Hyun-Kook Shin

    2006-08-01

    Full Text Available A new Digital Reactor Protection System (DRPS based on VME bus Single Board Computer has been developed by KOPEC to prevent software Common Mode Failure(CMF inside digital system. The new DRPS has been proved to be an effective digital safety system to prevent CMF by Defense-in-Depth and Diversity (DID&D analysis. However, for practical use in Nuclear Power Plants, the performance test and the reliability test are essential for the digital system qualification. In this study, a single channel of DRPS prototype has been manufactured for the evaluation of DRPS capabilities. The integrated functional tests are performed and the system reliability is analyzed and tested. The results of reliability test show that the application software of DRPS has a very high reliability compared with the analog reactor protection systems.

  10. An equivalent ground thermal test method for single-phase fluid loop space radiator

    Directory of Open Access Journals (Sweden)

    Xianwen Ning

    2015-02-01

    Full Text Available Thermal vacuum test is widely used for the ground validation of spacecraft thermal control system. However, the conduction and convection can be simulated in normal ground pressure environment completely. By the employment of pumped fluid loops’ thermal control technology on spacecraft, conduction and convection become the main heat transfer behavior between radiator and inside cabin. As long as the heat transfer behavior between radiator and outer space can be equivalently simulated in normal pressure, the thermal vacuum test can be substituted by the normal ground pressure thermal test. In this paper, an equivalent normal pressure thermal test method for the spacecraft single-phase fluid loop radiator is proposed. The heat radiation between radiator and outer space has been equivalently simulated by combination of a group of refrigerators and thermal electrical cooler (TEC array. By adjusting the heat rejection of each device, the relationship between heat flux and surface temperature of the radiator can be maintained. To verify this method, a validating system has been built up and the experiments have been carried out. The results indicate that the proposed equivalent ground thermal test method can simulate the heat rejection performance of radiator correctly and the temperature error between in-orbit theory value and experiment result of the radiator is less than 0.5 °C, except for the equipment startup period. This provides a potential method for the thermal test of space systems especially for extra-large spacecraft which employs single-phase fluid loop radiator as thermal control approach.

  11. Reliability and Validity of the Inline Skating Skill Test

    Directory of Open Access Journals (Sweden)

    Ivan Radman, Lana Ruzic, Viktoria Padovan, Vjekoslav Cigrovski, Hrvoje Podnar

    2016-09-01

    Full Text Available This study aimed to examine the reliability and validity of the inline skating skill test. Based on previous skating experience forty-two skaters (26 female and 16 male were randomized into two groups (competitive level vs. recreational level. They performed the test four times, with a recovery time of 45 minutes between sessions. Prior to testing, the participants rated their skating skill using a scale from 1 to 10. The protocol included performance time measurement through a course, combining different skating techniques. Trivial changes in performance time between the repeated sessions were determined in both competitive females/males and recreational females/males (-1.7% [95% CI: -5.8–2.6%] – 2.2% [95% CI: 0.0–4.5%]. In all four subgroups, the skill test had a low mean within-individual variation (1.6% [95% CI: 1.2–2.4%] – 2.7% [95% CI: 2.1–4.0%] and high mean inter-session correlation (ICC = 0.97 [95% CI: 0.92–0.99] – 0.99 [95% CI: 0.98–1.00]. The comparison of detected typical errors and smallest worthwhile changes (calculated as standard deviations × 0.2 revealed that the skill test was able to track changes in skaters’ performances. Competitive-level skaters needed shorter time (24.4–26.4%, all p < 0.01 to complete the test in comparison to recreational-level skaters. Moreover, moderate correlation (ρ = 0.80–0.82; all p < 0.01 was observed between the participant’s self-rating and achieved performance times. In conclusion, the proposed test is a reliable and valid method to evaluate inline skating skills in amateur competitive and recreational level skaters. Further studies are needed to evaluate the reproducibility of this skill test in different populations including elite inline skaters.

  12. Influences on the Test-Retest Reliability of Functional Connectivity MRI and its Relationship with Behavioral Utility.

    Science.gov (United States)

    Noble, Stephanie; Spann, Marisa N; Tokoglu, Fuyuze; Shen, Xilin; Constable, R Todd; Scheinost, Dustin

    2017-11-01

    Best practices are currently being developed for the acquisition and processing of resting-state magnetic resonance imaging data used to estimate brain functional organization-or "functional connectivity." Standards have been proposed based on test-retest reliability, but open questions remain. These include how amount of data per subject influences whole-brain reliability, the influence of increasing runs versus sessions, the spatial distribution of reliability, the reliability of multivariate methods, and, crucially, how reliability maps onto prediction of behavior. We collected a dataset of 12 extensively sampled individuals (144 min data each across 2 identically configured scanners) to assess test-retest reliability of whole-brain connectivity within the generalizability theory framework. We used Human Connectome Project data to replicate these analyses and relate reliability to behavioral prediction. Overall, the historical 5-min scan produced poor reliability averaged across connections. Increasing the number of sessions was more beneficial than increasing runs. Reliability was lowest for subcortical connections and highest for within-network cortical connections. Multivariate reliability was greater than univariate. Finally, reliability could not be used to improve prediction; these findings are among the first to underscore this distinction for functional connectivity. A comprehensive understanding of test-retest reliability, including its limitations, supports the development of best practices in the field. © The Author 2017. Published by Oxford University Press.

  13. Core thermal response during Semiscale Mod-1 blowdown heat transfer tests

    International Nuclear Information System (INIS)

    Larson, T.K.

    1976-06-01

    Selected experimental data and results calculated from experimental data obtained from the Semiscale Mod-1 PWR blowdown heat transfer test series are analyzed. These tests were designed primarily to provide information on the core thermal response to a loss-of-coolant accident. The data are analyzed to determine the effect of core flow on the heater rod thermal response. The data are also analyzed to determine the effects of initial operating conditions on the rod cladding temperature behavior during the transient. The departure from nucleate boiling and rewetting characteristics of the rod surfaces are examined for radial and axial patterns in the response. Repeatability of core thermal response data is also investigated. The test data and the core thermal response calculated with the RELAP4 code are compared

  14. The Reliability of a Functional Agility Test for Water Polo

    Directory of Open Access Journals (Sweden)

    Tucher Guilherme

    2014-07-01

    Full Text Available Few functional agility tests for water polo take into consideration its specific characteristics. The preliminary objective of this study was to evaluate the reliability of an agility test for water polo players. Fifteen players (16.3 ± 1.8 years old with a minimum of two years of competitive experience were evaluated. A Functional Test for Agility Performance (FTAP was designed to represent the context of this sport. Several trials were performed to familiarize the athlete with the movement. Two experienced coaches measured three repetitions of the FTAP. Descriptive statistics, repeated measures analysis of variance (ANOVA, 95% limit of agreement (LOA, intraclass correlation coefficient (ICC and standard error of measurements (SEM were used for data analysis. It was considered that certain criteria of reliability measures were met. There was no significant difference between the repetitions, which may be explained by an effect of the evaluator, the ability of the players or fatigue (p > 0.05. The ICC average from evaluators was high (0.88. The SEM varied between 0.13 s and 0.49 s. The CV average considering each individual was near 6-7%. These values depended on the condition of measurement. As the FTAP contains some characteristics that create a degree of unpredictability, the same athlete may reach different performance results, increasing variability. An adjustment in the sample, familiarization and careful selection of subjects help to improve this situation and enhance the reliability of the indicators.

  15. Construct validity and reliability of automated body reaction test ...

    African Journals Online (AJOL)

    Automated Body Reaction Test (ABRT) is a new device for skills and physical assessment instrument to measure ability on react, move quickly and accurately in accordance with stimulus. A total of 474 subjects aged 7-17 years old were randomly selected for the construct validity (n=330) and reliability (n=144). The ABRT ...

  16. Users manual on database of the Piping Reliability Proving Tests at the Japan Atomic Energy Research Institute

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-09-01

    Japan Atomic Energy Research Institute(JAERI) conducted Piping Reliability Proving Tests from 1975 to 1992 based upon the contracts between JAERI and Science and Technology Agency of Japan under the auspices of the special account law for electric power development promotion. The purposes of those tests are to prove the structural reliability of the primary cooling piping constituting a part of the pressure boundary in the water reactor power plants. The tests with large experimental facilities had ended already in 1990. After that piping reliability analysis by the probabilistic method followed until 1992. This report describes the users manual on databases about the test results using the large experimental facilities. Objectives of the piping reliability proving tests are to prove that the primary piping of the water reactor (1) be reliable throughout the service period, (2) have no possibility of rupture, (3) bring no detrimental influence on the surrounding instrumentations or equipments near the break location. The research activities using large scale piping test facilities are described. The present report does the database about the test results pairing the former report. With these two reports, all the feature of Piping Reliability Proving Tests is made clear. Briefings of the tests are described also written in Japanese or English. (author)

  17. Thermal property testing technique on micro specimen

    International Nuclear Information System (INIS)

    Baba, Tetsuya; Kishimoto, Isao; Taketoshi, Naoyuki

    2000-01-01

    This study aims at establishment of further development on some testing techniques on the nuclear advanced basic research accumulated by the National Research Laboratory of Metrology for ten years. For this purpose, a technology to test heat diffusion ratio and specific heat capacity of less than 3 mm in diameter and 1 mm in thickness of micro specimen and technology to test heat diffusion ratio at micro area of less than 1 mm in area along cross section of less than 10 mm in diameter of column specimen were developed to contribute to common basic technology supporting the nuclear power field. As a result, as an element technology to test heat diffusion ratio and specific heat capacity of the micro specimen, a specimen holding technique stably to hold a micro specimen with 3 mm in diameter could be developed. And, for testing the specific heat capacity by using the laser flush differential calorimetry, a technique to hold two specimen of 5 mm in diameter at their proximities was also developed. In addition, by promoting development of thermal property data base capable of storing thermal property data obtained in this study and with excellent workability in this 1998 fiscal year a data in/out-put program with graphical user interface could be prepared. (G.K.)

  18. Diagnostic reliability of MMPI-2 computer-based test interpretations.

    Science.gov (United States)

    Pant, Hina; McCabe, Brian J; Deskovitz, Mark A; Weed, Nathan C; Williams, John E

    2014-09-01

    Reflecting the common use of the MMPI-2 to provide diagnostic considerations, computer-based test interpretations (CBTIs) also typically offer diagnostic suggestions. However, these diagnostic suggestions can sometimes be shown to vary widely across different CBTI programs even for identical MMPI-2 profiles. The present study evaluated the diagnostic reliability of 6 commercially available CBTIs using a 20-item Q-sort task developed for this study. Four raters each sorted diagnostic classifications based on these 6 CBTI reports for 20 MMPI-2 profiles. Two questions were addressed. First, do users of CBTIs understand the diagnostic information contained within the reports similarly? Overall, diagnostic sorts of the CBTIs showed moderate inter-interpreter diagnostic reliability (mean r = .56), with sorts for the 1/2/3 profile showing the highest inter-interpreter diagnostic reliability (mean r = .67). Second, do different CBTIs programs vary with respect to diagnostic suggestions? It was found that diagnostic sorts of the CBTIs had a mean inter-CBTI diagnostic reliability of r = .56, indicating moderate but not strong agreement across CBTIs in terms of diagnostic suggestions. The strongest inter-CBTI diagnostic agreement was found for sorts of the 1/2/3 profile CBTIs (mean r = .71). Limitations and future directions are discussed. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  19. Feasibility and Reliability of Physical Fitness Tests in Older Adults with Intellectual Disability: A Pilot Study

    Science.gov (United States)

    Hilgenkamp, Thessa I. M.; van Wijck, Ruud; Evenhuis, Heleen M.

    2012-01-01

    Background: Physical fitness is relevant for wellbeing and health, but knowledge on the feasibility and reliability of instruments to measure physical fitness for older adults with intellectual disability is lacking. Methods: Feasibility and test-retest reliability of a physical fitness test battery (Box and Block Test, Response Time Test, walking…

  20. 75 FR 29962 - Special Conditions: Cirrus Design Corporation Model SF50 Airplane; Function and Reliability Testing

    Science.gov (United States)

    2010-05-28

    ... SF50 airplanes. 1. Function and Reliability Testing Flight tests: In place of 14 CFR part 21.35(b)(2... Reliability Testing AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of proposed special..., 1951, and deleted the service test requirements in Section 3.19 for airplanes of 6,000 pounds maximum...

  1. The navicular position test - a reliable measure of the navicular bone position during rest and loading

    DEFF Research Database (Denmark)

    Spörndly-Nees, Søren; Dåsberg, Brian; Nielsen, Rasmus Oestergaard

    2011-01-01

    .08 degrees, ICC = 0.91. Discussion: The present data support The Navicular Position Test as a reliable test of the navicular bone position during rest and loading measured in a simple test set-up. Conclusion: The Navicular Position Test was shown to have a high intraday-, intra- and inter-tester reliability...

  2. Reliability of cognitive tests of ELSA-Brasil, the brazilian longitudinal study of adult health

    Science.gov (United States)

    Batista, Juliana Alves; Giatti, Luana; Barreto, Sandhi Maria; Galery, Ana Roscoe Papini; Passos, Valéria Maria de Azeredo

    2013-01-01

    Cognitive function evaluation entails the use of neuropsychological tests, applied exclusively or in sequence. The results of these tests may be influenced by factors related to the environment, the interviewer or the interviewee. OBJECTIVES We examined the test-retest reliability of some tests of the Brazilian version from the Consortium to Establish a Registry for Alzheimer's disease. METHODS The ELSA-Brasil is a multicentre study of civil servants (35-74 years of age) from public institutions across six Brazilian States. The same tests were applied, in different order of appearance, by the same trained and certified interviewer, with an approximate 20-day interval, to 160 adults (51% men, mean age 52 years). The Intraclass Correlation Coefficient (ICC) was used to assess the reliability of the measures; and a dispersion graph was used to examine the patterns of agreement between them. RESULTS We observed higher retest scores in all tests as well as a shorter test completion time for the Trail Making Test B. ICC values for each test were as following: Word List Learning Test (0.56), Word Recall (0.50), Word Recognition (0.35), Phonemic Verbal Fluency Test (VFT, 0.61), Semantic VFT (0.53) and Trail B (0.91). The Bland-Altman plot showed better correlation of executive function (VFT and Trail B) than of memory tests. CONCLUSIONS Better performance in retest may reflect a learning effect, and suggest that retest should be repeated using alternate forms or after longer periods. In this sample of adults with high schooling level, reliability was only moderate for memory tests whereas the measurement of executive function proved more reliable. PMID:29213860

  3. Reliability of Cognitive Tests of ELSA-Brasil, the Brazilian Longitudinal Study of Adult Health

    Directory of Open Access Journals (Sweden)

    Juliana Alves Batista

    Full Text Available ABSTRACT Cognitive function evaluation entails the use of neuropsychological tests, applied exclusively or in sequence. The results of these tests may be influenced by factors related to the environment, the interviewer or the interviewee. Objectives: We examined the test-retest reliability of some tests of the Brazilian version from the Consortium to Establish a Registry for Alzheimer's disease. Methods: The ELSA-Brasil is a multicentre study of civil servants (35-74 years of age from public institutions across six Brazilian States. The same tests were applied, in different order of appearance, by the same trained and certified interviewer, with an approximate 20-day interval, to 160 adults (51% men, mean age 52 years. The Intraclass Correlation Coefficient (ICC was used to assess the reliability of the measures; and a dispersion graph was used to examine the patterns of agreement between them. Results: We observed higher retest scores in all tests as well as a shorter test completion time for the Trail Making Test B. ICC values for each test were as following: Word List Learning Test (0.56, Word Recall (0.50, Word Recognition (0.35, Phonemic Verbal Fluency Test (VFT, 0.61, Semantic VFT (0.53 and Trail B (0.91. The Bland-Altman plot showed better correlation of executive function (VFT and Trail B than of memory tests. Conclusions: Better performance in retest may reflect a learning effect, and suggest that retest should be repeated using alternate forms or after longer periods. In this sample of adults with high schooling level, reliability was only moderate for memory tests whereas the measurement of executive function proved more reliable.

  4. Increasing the reliability of the fluid/crystallized difference score from the Kaufman Adolescent and Adult Intelligence Test with reliable component analysis.

    Science.gov (United States)

    Caruso, J C

    2001-06-01

    The unreliability of difference scores is a well documented phenomenon in the social sciences and has led researchers and practitioners to interpret differences cautiously, if at all. In the case of the Kaufman Adult and Adolescent Intelligence Test (KAIT), the unreliability of the difference between the Fluid IQ and the Crystallized IQ is due to the high correlation between the two scales. The consequences of the lack of precision with which differences are identified are wide confidence intervals and unpowerful significance tests (i.e., large differences are required to be declared statistically significant). Reliable component analysis (RCA) was performed on the subtests of the KAIT in order to address these problems. RCA is a new data reduction technique that results in uncorrelated component scores with maximum proportions of reliable variance. Results indicate that the scores defined by RCA have discriminant and convergent validity (with respect to the equally weighted scores) and that differences between the scores, derived from a single testing session, were more reliable than differences derived from equal weighting for each age group (11-14 years, 15-34 years, 35-85+ years). This reliability advantage results in narrower confidence intervals around difference scores and smaller differences required for statistical significance.

  5. Validity and Reliability Testing of an e-learning Questionnaire for Chemistry Instruction

    Science.gov (United States)

    Guspatni, G.; Kurniawati, Y.

    2018-04-01

    The aim of this paper is to examine validity and reliability of a questionnaire used to evaluate e-learning implementation in chemistry instruction. 48 questionnaires were filled in by students who had studied chemistry through e-learning system. The questionnaire consisted of 20 indicators evaluating students’ perception on using e-learning. Parametric testing was done as data were assumed to follow normal distribution. Item validity of the questionnaire was examined through item-total correlation using Pearson’s formula while its reliability was assessed with Cronbach’s alpha formula. Moreover, convergent validity was assessed to see whether indicators building a factor had theoretically the same underlying construct. The result of validity testing revealed 19 valid indicators while the result of reliability testing revealed Cronbach’s alpha value of .886. The result of factor analysis showed that questionnaire consisted of five factors, and each of them had indicators building the same construct. This article shows the importance of factor analysis to get a construct valid questionnaire before it is used as research instrument.

  6. Thermal shock testing of ceramics with pulsed laser irradiation

    International Nuclear Information System (INIS)

    Benz, R.; Naoumidis, A.; Nickel, H.

    1986-04-01

    Arguments are presented showing that the resistance to thermal stressing (''thermal shock'') under pulsed thermal energy deposition by various kinds of beam irradiations is approximately proportional to Φ a √tp, where Φ a is the absorbed power density and tp is the pulse length, under conditions of diffusivity controlled spreading of heat. In practical beam irradiation testing, incident power density, Φ, is reported. To evaluate the usefulness of Φ√tp as an approximation to Φ a √tp, damage threshold values are reviewed for different kinds of beams (electron, proton, and laser) for a range of tp values 5x10 -6 to 2 s. Ruby laser beam irradiation tests were made on the following ceramics: AlN, BN, graphite, αSiC, β-SiC coated graphites, (α+β)Si 3 N 4 , CVD (chemical vapor deposition) TiC coated graphite, CVD TiC coated Mo, and CVD TiN coated IN 625. The identified failure mechanisms are: 1. plastic flow followed by tensile and bend fracturing, 2. chemical decomposition, 3. melting, and 4. loss by thermal spallation. In view of the theoretical approximations and the neglect of reflection losses there is reasonable accord between the damage threshold Φ√tp values from the laser, electron, and proton beam tests. (orig./IHOE)

  7. Test-Retest Reliability and Practice Effects of the Stability Evaluation Test.

    Science.gov (United States)

    Williams, Richelle M; Corvo, Matthew A; Lam, Kenneth C; Williams, Travis A; Gilmer, Lesley K; McLeod, Tamara C Valovich

    2017-01-17

    Postural control plays an essential role in concussion evaluation. The Stability Evaluation Test (SET) aims to objectively analyze postural control by measuring sway velocity on the NeuroCom's VSR portable force platform (Natus, San Carlos, CA). To assess the test-retest reliability and practice effects of the SET protocol. Cohort. Research Laboratory. Fifty healthy adults (males=20, females=30, age=25.30±3.60 years, height=166.60±12.80 cm, mass=68.80±13.90 kg). All participants completed four trials of the SET. Each trial consisted of six 20-second balance tests with eyes closed, under the following conditions: double-leg firm (DFi), single-leg firm (SFi), tandem firm (TFi), double-leg foam (DFo), single-leg foam (SFo), and tandem foam (TFo). Each trial was separated by a 5-minute seated rest period. The dependent variable was sway velocity (deg/sec), with lower values indicating better balance. Sway velocity was recorded for each of the six conditions as well as a composite score for each trial. Test-retest reliability was analyzed across four trials with Intraclass Correlation Coefficients. Practice effects analyzed with repeated measures analysis of variance, followed by Tukey post-hoc comparisons for any significant main effects (preliability values were good to excellent: DFi (ICC=0.88;95%CI:0.81,0.92), SFi (ICC=0.75;95%CI:0.61,0.85), TFi (ICC=0.84;95%CI:0.75,0.90), DFo (ICC=0.83;95%CI:0.74,0.90), SFo (ICC=0.82;95%CI:0.72,0.89), TFo (ICC=0.81;95%CI:0.69,0.88), and composite score (ICC=0.93;95%CI:0.88,0.95). Significant practice effects (preliability for the assessment of postural control in healthy adults. Due to the practice effects noted, a familiarization session is recommended (i.e., all 6 conditions) prior to recording the data. Future studies should evaluate injured patients to determine meaningful change scores during various injuries.

  8. Development, test-retest reliability, and construct validity of the resistance training skills battery.

    Science.gov (United States)

    Lubans, David R; Smith, Jordan J; Harries, Simon K; Barnett, Lisa M; Faigenbaum, Avery D

    2014-05-01

    The aim of this study was to describe the development and assess test-retest reliability and construct validity of the Resistance Training Skills Battery (RTSB) for adolescents. The RTSB provides an assessment of resistance training skill competency and includes 6 exercises (i.e., body weight squat, push-up, lunge, suspended row, standing overhead press, and front support with chest touches). Scoring for each skill is based on the number of performance criteria successfully demonstrated. An overall resistance training skill quotient (RTSQ) is created by adding participants' scores for the 6 skills. Participants (44 boys and 19 girls, mean age = 14.5 ± 1.2 years) completed the RTSB on 2 occasions separated by 7 days. Participants also completed the following fitness tests, which were used to create a muscular fitness score (MFS): handgrip strength, timed push-up, and standing long jump tests. Intraclass correlation (ICC), paired samples t-tests, and typical error were used to assess test-retest reliability. To assess construct validity, gender and RTSQ were entered into a regression model predicting MFS. The rank order repeatability of the RTSQ was high (ICC = 0.88). The model explained 39% of the variance in MFS (p ≤ 0.001) and RTSQ (r = 0.40, p ≤ 0.001) was a significant predictor. This study has demonstrated the construct validity and test-retest reliability of the RTSB in a sample of adolescents. The RTSB can reliably rank participants in regards to their resistance training competency and has the necessary sensitivity to detect small changes in resistance training skill proficiency.

  9. Is gait variability reliable in older adults and Parkinson's disease? Towards an optimal testing protocol.

    Science.gov (United States)

    Galna, Brook; Lord, Sue; Rochester, Lynn

    2013-04-01

    Despite the widespread use of gait variability in research and clinical studies, testing protocols designed to optimise its reliability have not been established. This study evaluates the impact of testing protocol and pathology on the reliability of gait variability. To (i) estimate the reliability of gait variability during continuous and intermittent walking protocols in older adults and people with Parkinson's disease (PD), (ii) determine optimal number of steps for acceptable levels of reliability of gait variability and (iii) provide sample size estimates for use in clinical trials. Gait variability was measured twice, one week apart, in 27 older adults and 25 PD participants. Participants walked at their preferred pace during: (i) a continuous 2 min walk and (ii) 3 intermittent walks over a 12 m walkway. Gait variability was calculated as the within-person standard deviation for step velocity, length and width, and step, stance and swing duration. Reliability of gait variability ranged from poor to excellent (intra class correlations .041-.860; relative limits of agreement 34-89%). Gait variability was more reliable during continuous walks. Control and PD participants demonstrated similar reliability. Increasing the number of steps improved reliability, with most improvement seen across the first 30 steps. In this study, we identified testing protocols that improve the reliability of measuring gait variability. We recommend using a continuous walking protocol and to collect no fewer than 30 steps. Early PD does not appear to impact negatively on the reliability of gait variability. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. Resting-state test-retest reliability of a priori defined canonical networks over different preprocessing steps.

    Science.gov (United States)

    Varikuti, Deepthi P; Hoffstaedter, Felix; Genon, Sarah; Schwender, Holger; Reid, Andrew T; Eickhoff, Simon B

    2017-04-01

    Resting-state functional connectivity analysis has become a widely used method for the investigation of human brain connectivity and pathology. The measurement of neuronal activity by functional MRI, however, is impeded by various nuisance signals that reduce the stability of functional connectivity. Several methods exist to address this predicament, but little consensus has yet been reached on the most appropriate approach. Given the crucial importance of reliability for the development of clinical applications, we here investigated the effect of various confound removal approaches on the test-retest reliability of functional-connectivity estimates in two previously defined functional brain networks. Our results showed that gray matter masking improved the reliability of connectivity estimates, whereas denoising based on principal components analysis reduced it. We additionally observed that refraining from using any correction for global signals provided the best test-retest reliability, but failed to reproduce anti-correlations between what have been previously described as antagonistic networks. This suggests that improved reliability can come at the expense of potentially poorer biological validity. Consistent with this, we observed that reliability was proportional to the retained variance, which presumably included structured noise, such as reliable nuisance signals (for instance, noise induced by cardiac processes). We conclude that compromises are necessary between maximizing test-retest reliability and removing variance that may be attributable to non-neuronal sources.

  11. Resting-state test-retest reliability of a priori defined canonical networks over different preprocessing steps

    Science.gov (United States)

    Varikuti, Deepthi P.; Hoffstaedter, Felix; Genon, Sarah; Schwender, Holger; Reid, Andrew T.; Eickhoff, Simon B.

    2016-01-01

    Resting-state functional connectivity analysis has become a widely used method for the investigation of human brain connectivity and pathology. The measurement of neuronal activity by functional MRI, however, is impeded by various nuisance signals that reduce the stability of functional connectivity. Several methods exist to address this predicament, but little consensus has yet been reached on the most appropriate approach. Given the crucial importance of reliability for the development of clinical applications, we here investigated the effect of various confound removal approaches on the test-retest reliability of functional-connectivity estimates in two previously defined functional brain networks. Our results showed that grey matter masking improved the reliability of connectivity estimates, whereas de-noising based on principal components analysis reduced it. We additionally observed that refraining from using any correction for global signals provided the best test-retest reliability, but failed to reproduce anti-correlations between what have been previously described as antagonistic networks. This suggests that improved reliability can come at the expense of potentially poorer biological validity. Consistent with this, we observed that reliability was proportional to the retained variance, which presumably included structured noise, such as reliable nuisance signals (for instance, noise induced by cardiac processes). We conclude that compromises are necessary between maximizing test-retest reliability and removing variance that may be attributable to non-neuronal sources. PMID:27550015

  12. Thermal Development Test of the NEXT PM1 Ion Engine

    Science.gov (United States)

    Anderson, John R.; Snyder, John S.; VanNoord, Jonathan L.; Soulas, George C.

    2010-01-01

    NASA's Evolutionary Xenon Thruster (NEXT) is a next-generation high-power ion propulsion system under development by NASA as a part of the In-Space Propulsion Technology Program. NEXT is designed for use on robotic exploration missions of the solar system using solar electric power. Potential mission destinations that could benefit from a NEXT Solar Electric Propulsion (SEP) system include inner planets, small bodies, and outer planets and their moons. This range of robotic exploration missions generally calls for ion propulsion systems with deep throttling capability and system input power ranging from 0.6 to 25 kW, as referenced to solar array output at 1 Astronomical Unit (AU). Thermal development testing of the NEXT prototype model 1 (PM1) was conducted at JPL to assist in developing and validating a thruster thermal model and assessing the thermal design margins. NEXT PM1 performance prior to, during and subsequent to thermal testing are presented. Test results are compared to the predicted hot and cold environments expected missions and the functionality of the thruster for these missions is discussed.

  13. The prone bridge test: Performance, validity, and reliability among older and younger adults.

    Science.gov (United States)

    Bohannon, Richard W; Steffl, Michal; Glenney, Susan S; Green, Michelle; Cashwell, Leah; Prajerova, Kveta; Bunn, Jennifer

    2018-04-01

    The prone bridge maneuver, or plank, has been viewed as a potential alternative to curl-ups for assessing trunk muscle performance. The purpose of this study was to assess prone bridge test performance, validity, and reliability among younger and older adults. Sixty younger (20-35 years old) and 60 older (60-79 years old) participants completed this study. Groups were evenly divided by sex. Participants completed surveys regarding physical activity and abdominal exercise participation. Height, weight, body mass index (BMI), and waist circumference were measured. On two occasions, 5-9 days apart, participants held a prone bridge until volitional exhaustion or until repeated technique failure. Validity was examined using data from the first session: convergent validity by calculating correlations between survey responses, anthropometrics, and prone bridge time, known groups validity by using an ANOVA comparing bridge times of younger and older adults and of men and women. Test-retest reliability was examined by using a paired t-test to compare prone bridge times for Session1 and Session 2. Furthermore, an intraclass correlation coefficient (ICC) was used to characterize relative reliability and minimal detectable change (MDC 95% ) was used to describe absolute reliability. The mean prone bridge time was 145.3 ± 71.5 s, and was positively correlated with physical activity participation (p ≤ 0.001) and negatively correlated with BMI and waist circumference (p ≤ 0.003). Younger participants had significantly longer plank times than older participants (p = 0.003). The ICC between testing sessions was 0.915. The prone bridge test is a valid and reliable measure for evaluating abdominal performance in both younger and older adults. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Test-Retest Reliability of Dual-Task Outcome Measures in People With Parkinson Disease

    NARCIS (Netherlands)

    Strouwen, C.; Molenaar, E.A.; Keus, S.H.; Munks, L.; Bloem, B.R.; Nieuwboer, A.

    2016-01-01

    BACKGROUND: Dual-task (DT) training is gaining ground as a physical therapy intervention in people with Parkinson disease (PD). Future studies evaluating the effect of such interventions need reliable outcome measures. To date, the test-retest reliability of DT measures in patients with PD remains

  15. Assessing Reliability of Cold Spray Sputter Targets in Photovoltaic Manufacturing

    Science.gov (United States)

    Hardikar, Kedar; Vlcek, Johannes; Bheemreddy, Venkata; Juliano, Daniel

    2017-10-01

    Cold spray has been used to manufacture more than 800 Cu-In-Ga (CIG) sputter targets for deposition of high-efficiency photovoltaic thin films. It is a preferred technique since it enables high deposit purity and transfer of non-equilibrium alloy states to the target material. In this work, an integrated approach to reliability assessment of such targets with deposit weight in excess of 50 lb. is undertaken, involving thermal-mechanical characterization of the material in as-deposited condition, characterization of the interface adhesion on cylindrical substrate in as-deposited condition, and developing means to assess target integrity under thermal-mechanical loads during the physical vapor deposition (PVD) sputtering process. Mechanical characterization of cold spray deposited CIG alloy is accomplished through the use of indentation testing and adaptation of Brazilian disk test. A custom lever test was developed to characterize adhesion along the cylindrical interface between the CIG deposit and cylindrical substrate, overcoming limitations of current standards. A cohesive zone model for crack initiation and propagation at the deposit interface is developed and validated using the lever test and later used to simulate the potential catastrophic target failure in the PVD process. It is shown that this approach enables reliability assessment of sputter targets and improves robustness.

  16. The timed "up and go" test : Reliability and validity in persons with unilateral lower limb amputation

    NARCIS (Netherlands)

    Schoppen, Tanneke; Boonstra, Antje; Groothoff, JW; de Vries, J; Goeken, LNH; Eisma, Willem

    Objective: To determine the interrater and interrater reliability and the validity of the Timed "up and go" test as a measure for physical mobility in elderly patients with an amputation of the lower extremity. Design: To test interrater reliability, the test was performed for two observers at

  17. Construct Validity and Test-Retest Reliability of the Climbing Stairs Questionnaire in Lower-Limb Amputees

    NARCIS (Netherlands)

    de Laat, Fred A.; Rommers, Gerardus M.; Geertzen, Jan H.; Roorda, Leo D.

    de Laat FA, Rommers GM, Geertzen JH, Roorda LD. Construct validity and test-retest reliability of the Climbing Stairs Questionnaire in lower-limb amputees. Arch Phys Med Rehabil 2010;91:1396-401. Objective: To investigate the construct validity and test-retest reliability of the Climbing Stairs

  18. Reliable Decentralized Control of Fuzzy Discrete-Event Systems and a Test Algorithm.

    Science.gov (United States)

    Liu, Fuchun; Dziong, Zbigniew

    2013-02-01

    A framework for decentralized control of fuzzy discrete-event systems (FDESs) has been recently presented to guarantee the achievement of a given specification under the joint control of all local fuzzy supervisors. As a continuation, this paper addresses the reliable decentralized control of FDESs in face of possible failures of some local fuzzy supervisors. Roughly speaking, for an FDES equipped with n local fuzzy supervisors, a decentralized supervisor is called k-reliable (1 ≤ k ≤ n) provided that the control performance will not be degraded even when n - k local fuzzy supervisors fail. A necessary and sufficient condition for the existence of k-reliable decentralized supervisors of FDESs is proposed by introducing the notions of M̃uc-controllability and k-reliable coobservability of fuzzy language. In particular, a polynomial-time algorithm to test the k-reliable coobservability is developed by a constructive methodology, which indicates that the existence of k-reliable decentralized supervisors of FDESs can be checked with a polynomial complexity.

  19. Reliability assessment for safety critical systems by statistical random testing

    International Nuclear Information System (INIS)

    Mills, S.E.

    1995-11-01

    In this report we present an overview of reliability assessment for software and focus on some basic aspects of assessing reliability for safety critical systems by statistical random testing. We also discuss possible deviations from some essential assumptions on which the general methodology is based. These deviations appear quite likely in practical applications. We present and discuss possible remedies and adjustments and then undertake applying this methodology to a portion of the SDS1 software. We also indicate shortcomings of the methodology and possible avenues to address to follow to address these problems. (author). 128 refs., 11 tabs., 31 figs

  20. Reliability assessment for safety critical systems by statistical random testing

    Energy Technology Data Exchange (ETDEWEB)

    Mills, S E [Carleton Univ., Ottawa, ON (Canada). Statistical Consulting Centre

    1995-11-01

    In this report we present an overview of reliability assessment for software and focus on some basic aspects of assessing reliability for safety critical systems by statistical random testing. We also discuss possible deviations from some essential assumptions on which the general methodology is based. These deviations appear quite likely in practical applications. We present and discuss possible remedies and adjustments and then undertake applying this methodology to a portion of the SDS1 software. We also indicate shortcomings of the methodology and possible avenues to address to follow to address these problems. (author). 128 refs., 11 tabs., 31 figs.

  1. Power Electronics Packaging Reliability | Transportation Research | NREL

    Science.gov (United States)

    Packaging Reliability Power Electronics Packaging Reliability A photo of a piece of power electronics laboratory equipment. NREL power electronics packaging reliability research investigates the electronics packaging around a semiconductor switching device determines the electrical, thermal, and

  2. Reliability of non-destructive testing methods

    International Nuclear Information System (INIS)

    Broekhoven, M.J.G.

    1988-01-01

    This contribution regards the results of an evaluation of the reliability of radiography (X-rays and gamma-rays), manual-, and mechanized/automated ultrasonic examination by generally accepted codes/rules, with respect to detection, characterization and sizing/localization of defects. The evaluation is based on the results of examinations, by a number of teams, of 30 test plates, 30 and 50 mm thickness, containing V,U, X and K-shaped welds each containing several types of imperfections (211) in total) typical for steel arc fusion welding, such as porosity, inclusions, lack of fusion or penetration and cracks. Besides, some results are presented obtained from research on advanced UT-techniques, viz. the time-of-flight-diffraction and flaw-tip deflection technique. (author)

  3. Reliability of non-destructive testing methods

    Energy Technology Data Exchange (ETDEWEB)

    Broekhoven, M J.G. [Ministry of Social Affairs, (Netherlands)

    1988-12-31

    This contribution regards the results of an evaluation of the reliability of radiography (X-rays and gamma-rays), manual-, and mechanized/automated ultrasonic examination by generally accepted codes/rules, with respect to detection, characterization and sizing/localization of defects. The evaluation is based on the results of examinations, by a number of teams, of 30 test plates, 30 and 50 mm thickness, containing V,U, X and K-shaped welds each containing several types of imperfections (211) in total) typical for steel arc fusion welding, such as porosity, inclusions, lack of fusion or penetration and cracks. Besides, some results are presented obtained from research on advanced UT-techniques, viz. the time-of-flight-diffraction and flaw-tip deflection technique. (author). 4 refs.

  4. Intra- and inter-rater reliability of movement and palpation tests in patients with neck pain: A systematic review.

    Science.gov (United States)

    Jonsson, Anders; Rasmussen-Barr, Eva

    2018-03-01

    Neck pain is common and often becomes chronic. Various clinical tests of the cervical spine are used to direct and evaluate treatment. This systematic review aimed to identify studies examining the intra- and/or interrater reliability of tests used in clinical examination of patients with neck pain. A database search up to April 2016 was conducted in PubMed, CINAHL, and AMED. The Quality Appraisal of Reliability Studies Checklist (QAREL) was used to assess risk of bias. Eleven studies were included, comprising tests of active and passive movement and pain evaluating participants with ongoing neck pain. One study was assessed with a low risk of bias, three with medium risk, while the rest were assessed with high risk of bias. The results showed differing reliabilities for the included tests ranging from poor to almost perfect. In conclusion, active movement and pain for pain or mobility overall presented acceptable to very good reliability (Kappa >0.40); while passive intervertebral tests had lower Kappa values, suggesting poor reliability. It may be a coincidence that the studies indicating very good reliability tended to be of higher quality (low to moderate risk of bias), while studies finding poor reliability tended to be of lower quality (high risk of bias). Regardless, the current recommendation from this review would suggest the clinical use of tests with acceptable reliability and avoiding the use of tests that have been shown to not be reliable. Finally, it is critical that all future reliability studies are of higher quality with low risk of bias.

  5. Reliability and criterion-related validity testing (construct) of the Endotracheal Suction Assessment Tool (ESAT©).

    Science.gov (United States)

    Davies, Kylie; Bulsara, Max K; Ramelet, Anne-Sylvie; Monterosso, Leanne

    2018-05-01

    To establish criterion-related construct validity and test-retest reliability for the Endotracheal Suction Assessment Tool© (ESAT©). Endotracheal tube suction performed in children can significantly affect clinical stability. Previously identified clinical indicators for endotracheal tube suction were used as criteria when designing the ESAT©. Content validity was reported previously. The final stages of psychometric testing are presented. Observational testing was used to measure construct validity and determine whether the ESAT© could guide "inexperienced" paediatric intensive care nurses' decision-making regarding endotracheal tube suction. Test-retest reliability of the ESAT© was performed at two time points. The researchers and paediatric intensive care nurse "experts" developed 10 hypothetical clinical scenarios with predetermined endotracheal tube suction outcomes. "Experienced" (n = 12) and "inexperienced" (n = 14) paediatric intensive care nurses were presented with the scenarios and the ESAT© guiding decision-making about whether to perform endotracheal tube suction for each scenario. Outcomes were compared with those predetermined by the "experts" (n = 9). Test-retest reliability of the ESAT© was measured at two consecutive time points (4 weeks apart) with "experienced" and "inexperienced" paediatric intensive care nurses using the same scenarios and tool to guide decision-making. No differences were observed between endotracheal tube suction decisions made by "experts" (n = 9), "inexperienced" (n = 14) and "experienced" (n = 12) nurses confirming the tool's construct validity. No differences were observed between groups for endotracheal tube suction decisions at T1 and T2. Criterion-related construct validity and test-retest reliability of the ESAT© were demonstrated. Further testing is recommended to confirm reliability in the clinical setting with the "inexperienced" nurse to guide decision-making related to endotracheal tube

  6. Impact of Relationships between Test and Reference Animals and between Reference Animals on Reliability of Genomic Prediction

    DEFF Research Database (Denmark)

    Wu, Xiaoping; Lund, Mogens Sandø; Sun, Dongxiao

    This study investigated reliability of genomic prediction in various scenarios with regard to relationship between test and reference animals and between animals within the reference population. Different reference populations were generated from EuroGenomics data and 1288 Nordic Holstein bulls...... as a common test population. A GBLUP model and a Bayesian mixture model were applied to predict Genomic breeding values for bulls in the test data. Result showed that a closer relationship between test and reference animals led to a higher reliability, while a closer relationship between reference animal...... resulted in a lower reliability. Therefore, the design of reference population is important for improving the reliability of genomic prediction. With regard to model, the Bayesian mixture model in general led to slightly a higher reliability of genomic prediction than the GBLUP model...

  7. Levodopa responsiveness of dysphagia in advanced Parkinson's disease and reliability testing of the FEES-Levodopa-test.

    Science.gov (United States)

    Warnecke, Tobias; Suttrup, Inga; Schröder, Jens B; Osada, Nani; Oelenberg, Stephan; Hamacher, Christina; Suntrup, Sonja; Dziewas, Rainer

    2016-07-01

    It is still controversially discussed whether central dopaminergic stimulation improves swallowing ability in Parkinson's disease (PD). We evaluated the effect of oral levodopa application on dysphagia in advanced PD patients with motor fluctuations. In 15 PD patients (mean age 71.93 ± 8.29 years, mean disease duration 14.33 ± 5.94 years) with oropharyngeal dysphagia and motor fluctuations endoscopic swallowing evaluation was performed in the off state and on state condition following a specifically developed protocol (FEES-levodopa-test). The respective dysphagia score covered three salient parameters, i. e. premature spillage, penetration/aspiration events and residues, each tested with liquid as well as semisolid and solid food consistencies. An improvement of >30% in this score indicated levodopa responsiveness of dysphagia. Measures were compared between the off- and on-state condition by using the Wilcoxon Test and marginal homogeneity test. Inter- and intrarater reliability was also investigated. Severity of swallowing dysfunction in the off state varied widely. The lowest dysphagia score was 15 points (dysphagia without any aspiration risk). The highest dysphagia score was 84 points (dysphagia with aspiration of all consistencies). Seven patients showed a marked improvement of dysphagia in the on state condition. Eight PD patients did not respond. Inter- and intrarater reliability was excellent for all three subscales in the off state and on state conditions. A significant proportion of advanced PD patients with motor fluctuations and mild to moderate oropharyngeal dysphagia may demonstrate a clinically relevant improvement of swallowing after levodopa challenge. The FEES-levodopa-test is a reliable and sensitive tool to differentiate these responders from non-responders. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Maximal cardiorespiratory fitness testing in individuals with chronic stroke with cognitive impairment: practice test effects and test-retest reliability.

    Science.gov (United States)

    Olivier, Charles; Doré, Jean; Blanchet, Sophie; Brooks, Dina; Richards, Carol L; Martel, Guy; Robitaille, Nancy-Michelle; Maltais, Désirée B

    2013-11-01

    To evaluate, for individuals with chronic stroke with cognitive impairment, (1) the effects of a practice test on peak cardiorespiratory fitness test results; (2) cardiorespiratory fitness test-retest reliability; and (3) the relationship between individual practice test effects and cognitive impairment. Cross-sectional. Rehabilitation center. A convenience sample of 21 persons (men [n=12] and women [n=9]; age range, 48-81y; 44.9±36.2mo poststroke) with cognitive impairments who had sufficient lower limb function to perform the test. Not applicable. Peak oxygen consumption (Vo(2)peak, ml·kg(-1)·min(-1)). Test-retest reliability of Vo(2)peak was excellent (intraclass correlation coefficient model 2,1 [ICC2,1]=.94; 95% confidence interval [CI], .86-.98). A paired t test showed that there was no significant difference for the group for Vo(2)peak obtained from 2 symptom-limited cardiorespiratory fitness tests performed 1 week apart on a semirecumbent cycle ergometer (test 2-test 1 difference, -.32ml·kg(-1)·min(-1); 95% CI, -.69 to 1.33ml·kg(-1)·min(-1); P=.512). Individual test-retest differences in Vo(2)peak were, however, positively related to general cognitive function as measured by the Mini-Mental State Examination (ρ=.485; Preliably measured in this group without a practice test. General cognitive function, however, may influence the effect of a practice test in that those with lower general cognitive function appear to respond differently to a practice test than those with higher cognitive function. Copyright © 2013 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  9. Reliability of Ceramic Column Grid Array Interconnect Packages Under Extreme Temperatures

    Science.gov (United States)

    Ramesham, Rajeshuni

    2011-01-01

    A paper describes advanced ceramic column grid array (CCGA) packaging interconnects technology test objects that were subjected to extreme temperature thermal cycles. CCGA interconnect electronic package printed wiring boards (PWBs) of polyimide were assembled, inspected nondestructively, and, subsequently, subjected to ex - treme-temperature thermal cycling to assess reliability for future deep-space, short- and long-term, extreme-temperature missions. The test hardware consisted of two CCGA717 packages with each package divided into four daisy-chained sections, for a total of eight daisy chains to be monitored. The package is 33 33 mm with a 27 27 array of 80%/20% Pb/Sn columns on a 1.27-mm pitch. The change in resistance of the daisy-chained CCGA interconnects was measured as a function of the increasing number of thermal cycles. Several catastrophic failures were observed after 137 extreme-temperature thermal cycles, as per electrical resistance measurements, and then the tests were continued through 1,058 thermal cycles to corroborate and understand the test results. X-ray and optical inspection have been made after thermal cycling. Optical inspections were also conducted on the CCGA vs. thermal cycles. The optical inspections were conclusive; the x-ray images were not. Process qualification and assembly is required to optimize the CCGA assembly, which is very clear from the x-rays. Six daisy chains were open out of seven daisy chains, as per experimental test data reported. The daisy chains are open during the cold cycle, and then recover during the hot cycle, though some of them also opened during the hot thermal cycle..

  10. Interrater reliability assessment using the Test of Gross Motor Development-2.

    Science.gov (United States)

    Barnett, Lisa M; Minto, Christine; Lander, Natalie; Hardy, Louise L

    2014-11-01

    The aim was to examine interrater reliability of the object control subtest from the Test of Gross Motor Development-2 by live observation in a school field setting. Reliability Study--cross sectional. Raters were rated on their ability to agree on (1) the raw total for the six object control skills; (2) each skill performance and (3) the skill components. Agreement for the object control subtest and the individual skills was assessed by an intraclass correlation (ICC) and a kappa statistic assessed for skill component agreement. A total of 37 children (65% girls) aged 4-8 years (M = 6.2, SD = 0.8) were assessed in six skills by two raters; equating to 222 skill tests. Interrater reliability was excellent for the object control subset (ICC = 0.93), and for individual skills, highest for the dribble (ICC = 0.94) followed by strike (ICC = 0.85), overhand throw (ICC = 0.84), underhand roll (ICC = 0.82), kick (ICC = 0.80) and the catch (ICC = 0.71). The strike and the throw had more components with less agreement. Even though the overall subtest score and individual skill agreement was good, some skill components had lower agreement, suggesting these may be more problematic to assess. This may mean some skill components need to be specified differently in order to improve component reliability. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  11. Thermal results of the Japanese LCT coil's domestic test

    International Nuclear Information System (INIS)

    Tada, Eisuke; Hiyama, Tadao; Kato, Takashi; Takahashi, Osamu; Shimamoto, Susumu

    1984-01-01

    This paper describes thermal results obtained in the domestic test of the Japanese LCT coil which was constructed at the Japan Atomic Energy Research Institute (JAERI) in order to develop large superconducting coils for fusion in international collaboration proposed by the IEA. The domestic test was carried out from May 13 to June 17 in 1982 by using the test facility named as SETF (Superconducting Engineering Test Facility) which was composed of a 350-l/h helium cryogenic system, a vacuum system, a 30 KA-DC power supply and protection system, and a PDP-11/70 computer system. The cool-down characteristics, heat load, fast discharge characteristics, stability, and warm-up characteristics of the LCT coil were successfully measured in the test. The details of thermal test results acquired in the cool-down, heat load measurement, fast discharge, and warm-up, and the comparison between measurements and calculations are described in this paper. (author)

  12. Test-retest reliability of the 40 Hz EEG auditory steady-state response.

    Directory of Open Access Journals (Sweden)

    Kristina L McFadden

    Full Text Available Auditory evoked steady-state responses are increasingly being used as a marker of brain function and dysfunction in various neuropsychiatric disorders, but research investigating the test-retest reliability of this response is lacking. The purpose of this study was to assess the consistency of the auditory steady-state response (ASSR across sessions. Furthermore, the current study aimed to investigate how the reliability of the ASSR is impacted by stimulus parameters and analysis method employed. The consistency of this response across two sessions spaced approximately 1 week apart was measured in nineteen healthy adults using electroencephalography (EEG. The ASSR was entrained by both 40 Hz amplitude-modulated white noise and click train stimuli. Correlations between sessions were assessed with two separate analytical techniques: a channel-level analysis across the whole-head array and b signal-space projection from auditory dipoles. Overall, the ASSR was significantly correlated between sessions 1 and 2 (p<0.05, multiple comparison corrected, suggesting adequate test-retest reliability of this response. The current study also suggests that measures of inter-trial phase coherence may be more reliable between sessions than measures of evoked power. Results were similar between the two analysis methods, but reliability varied depending on the presented stimulus, with click train stimuli producing more consistent responses than white noise stimuli.

  13. Integrated Electrical and Thermal Grid Facility - Testing of Future Microgrid Technologies

    Directory of Open Access Journals (Sweden)

    Sundar Raj Thangavelu

    2015-09-01

    Full Text Available This paper describes the Experimental Power Grid Centre (EPGC microgrid test facility, which was developed to enable research, development and testing for a wide range of distributed generation and microgrid technologies. The EPGC microgrid facility comprises a integrated electrical and thermal grid with a flexible and configurable architecture, and includes various distributed energy resources and emulators, such as generators, renewable, energy storage technologies and programmable load banks. The integrated thermal grid provides an opportunity to harness waste heat produced by the generators for combined heat, power and cooling applications, and support research in optimization of combined electrical-thermal systems. Several case studies are presented to demonstrate the testing of different control and operation strategies for storage systems in grid-connected and islanded microgrids. One of the case studies also demonstrates an integrated thermal grid to convert waste heat to useful energy, which thus far resulted in a higher combined energy efficiency. Experiment results confirm that the facility enables testing and evaluation of grid technologies and practical problems that may not be apparent in a computer simulated environment.

  14. Reliability demonstration test for load-sharing systems with exponential and Weibull components.

    Directory of Open Access Journals (Sweden)

    Jianyu Xu

    Full Text Available Conducting a Reliability Demonstration Test (RDT is a crucial step in production. Products are tested under certain schemes to demonstrate whether their reliability indices reach pre-specified thresholds. Test schemes for RDT have been studied in different situations, e.g., lifetime testing, degradation testing and accelerated testing. Systems designed with several structures are also investigated in many RDT plans. Despite the availability of a range of test plans for different systems, RDT planning for load-sharing systems hasn't yet received the attention it deserves. In this paper, we propose a demonstration method for two specific types of load-sharing systems with components subject to two distributions: exponential and Weibull. Based on the assumptions and interpretations made in several previous works on such load-sharing systems, we set the mean time to failure (MTTF of the total system as the demonstration target. We represent the MTTF as a summation of mean time between successive component failures. Next, we introduce generalized test statistics for both the underlying distributions. Finally, RDT plans for the two types of systems are established on the basis of these test statistics.

  15. An Operators View of Reliability Testing and Decay Heat Rejection Systems

    International Nuclear Information System (INIS)

    Henderson, J.D.C.

    1975-01-01

    The object of this paper is to review the in-situ testing of DHR systems, and to convey policy rather than to indicate a definitive test programme. The test policy is aimed primarily at commissioning the plant and secondly at providing such support for reliability predictions as is practical. Provisions for removal of decay heat from the core and from the reactor tank are described in papers by Broadley and Davies

  16. Automatically generated acceptance test: A software reliability experiment

    Science.gov (United States)

    Protzel, Peter W.

    1988-01-01

    This study presents results of a software reliability experiment investigating the feasibility of a new error detection method. The method can be used as an acceptance test and is solely based on empirical data about the behavior of internal states of a program. The experimental design uses the existing environment of a multi-version experiment previously conducted at the NASA Langley Research Center, in which the launch interceptor problem is used as a model. This allows the controlled experimental investigation of versions with well-known single and multiple faults, and the availability of an oracle permits the determination of the error detection performance of the test. Fault interaction phenomena are observed that have an amplifying effect on the number of error occurrences. Preliminary results indicate that all faults examined so far are detected by the acceptance test. This shows promise for further investigations, and for the employment of this test method on other applications.

  17. Validity and Reliability of Published Comprehensive Theory of Mind Tests for Normal Preschool Children: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Seyyede Zohreh Ziatabar Ahmadi

    2015-12-01

    Full Text Available Objective: Theory of mind (ToM or mindreading is an aspect of social cognition that evaluates mental states and beliefs of oneself and others. Validity and reliability are very important criteria when evaluating standard tests; and without them, these tests are not usable. The aim of this study was to systematically review the validity and reliability of published English comprehensive ToM tests developed for normal preschool children.Method: We searched MEDLINE (PubMed interface, Web of Science, Science direct, PsycINFO, and also evidence base Medicine (The Cochrane Library databases from 1990 to June 2015. Search strategy was Latin transcription of ‘Theory of Mind’ AND test AND children. Also, we manually studied the reference lists of all final searched articles and carried out a search of their references. Inclusion criteria were as follows: Valid and reliable diagnostic ToM tests published from 1990 to June 2015 for normal preschool children; and exclusion criteria were as follows: the studies that only used ToM tests and single tasks (false belief tasks for ToM assessment and/or had no description about structure, validity or reliability of their tests. Methodological quality of the selected articles was assessed using the Critical Appraisal Skills Programme (CASP.Result: In primary searching, we found 1237 articles in total databases. After removing duplicates and applying all inclusion and exclusion criteria, we selected 11 tests for this systematic review. Conclusion: There were a few valid, reliable and comprehensive ToM tests for normal preschool children. However, we had limitations concerning the included articles. The defined ToM tests were different in populations, tasks, mode of presentations, scoring, mode of responses, times and other variables. Also, they had various validities and reliabilities. Therefore, it is recommended that the researchers and clinicians select the ToM tests according to their psychometric

  18. Intersession reliability of self-selected and narrow stance balance testing in older adults.

    Science.gov (United States)

    Riemann, Bryan L; Piersol, Kelsey

    2017-10-01

    Despite the common practice of using force platforms to assess balance of older adults, few investigations have examined the reliability of postural screening tests in this population. We sought to determine the test-retest reliability of self-selected and narrow stance balance testing with eyes open and eyes closed in healthy older adults. Thirty older adults (>65 years) completed 45 s trials of eyes open and eyes closed stability tests using self-selected and narrow stances on two separate days (1.9 ± .7 days). Average medial-lateral center of pressure velocity was computed. The ICC results ranged from .74 to .86, and no significant systematic changes (P eyes open and closed balance testing using self-selected and narrow stances in older adults was established which should provide a foundation for the development of fall risk screening tests.

  19. Machine Learning Approach for Software Reliability Growth Modeling with Infinite Testing Effort Function

    Directory of Open Access Journals (Sweden)

    Subburaj Ramasamy

    2017-01-01

    Full Text Available Reliability is one of the quantifiable software quality attributes. Software Reliability Growth Models (SRGMs are used to assess the reliability achieved at different times of testing. Traditional time-based SRGMs may not be accurate enough in all situations where test effort varies with time. To overcome this lacuna, test effort was used instead of time in SRGMs. In the past, finite test effort functions were proposed, which may not be realistic as, at infinite testing time, test effort will be infinite. Hence in this paper, we propose an infinite test effort function in conjunction with a classical Nonhomogeneous Poisson Process (NHPP model. We use Artificial Neural Network (ANN for training the proposed model with software failure data. Here it is possible to get a large set of weights for the same model to describe the past failure data equally well. We use machine learning approach to select the appropriate set of weights for the model which will describe both the past and the future data well. We compare the performance of the proposed model with existing model using practical software failure data sets. The proposed log-power TEF based SRGM describes all types of failure data equally well and also improves the accuracy of parameter estimation more than existing TEF and can be used for software release time determination as well.

  20. Impact of relationships between test and training animals and among training animals on reliability of genomic prediction.

    Science.gov (United States)

    Wu, X; Lund, M S; Sun, D; Zhang, Q; Su, G

    2015-10-01

    One of the factors affecting the reliability of genomic prediction is the relationship among the animals of interest. This study investigated the reliability of genomic prediction in various scenarios with regard to the relationship between test and training animals, and among animals within the training data set. Different training data sets were generated from EuroGenomics data and a group of Nordic Holstein bulls (born in 2005 and afterwards) as a common test data set. Genomic breeding values were predicted using a genomic best linear unbiased prediction model and a Bayesian mixture model. The results showed that a closer relationship between test and training animals led to a higher reliability of genomic predictions for the test animals, while a closer relationship among training animals resulted in a lower reliability. In addition, the Bayesian mixture model in general led to a slightly higher reliability of genomic prediction, especially for the scenario of distant relationships between training and test animals. Therefore, to prevent a decrease in reliability, constant updates of the training population with animals from more recent generations are required. Moreover, a training population consisting of less-related animals is favourable for reliability of genomic prediction. © 2015 Blackwell Verlag GmbH.

  1. Comparison of thermal runaway limits under different test conditions based on a 4.5 kV IGBT

    DEFF Research Database (Denmark)

    Reigosa, Paula Diaz; Prindle, D.; Pâques, Gontran

    2016-01-01

    runaway takes place. In this paper guidelines are proposed based on the correlation among short circuit withstand capability and off-state leakage current for guarantying reliable operation and ensuring that they are thermally stable under parameter variations. This study is helpful to facilitate...... application engineers for defining the correct stability criteria and/or margins in respect of thermal runaway....

  2. Preparation, characterization, and thermal properties of microencapsulated phase change material for thermal energy storage

    Energy Technology Data Exchange (ETDEWEB)

    Alkan, Cemil; Sari, Ahmet; Karaipekli, Ali [Department of Chemistry, Gaziosmanpasa University, 60240 Tokat (Turkey); Uzun, Orhan [Department of Physics, Gaziosmanpasa University, 60240 Tokat (Turkey)

    2009-01-15

    This study is focused on the preparation, characterization, and determination of thermal properties of microencapsulated docosane with polymethylmethacrylate (PMMA) as phase change material for thermal energy storage. Microencapsulation of docosane has been carried out by emulsion polymerization. The microencapsulated phase change material (MEPCM) was characterized using scanning electron microscopy (SEM) and Fourier transform infrared (FT-IR) spectroscopy. Thermal properties and thermal stability of MEPCM were measured by differential scanning calorimetry (DSC) and thermal gravimetric analysis (TGA). DSC analysis indicated that the docosane in the microcapsules melts at 41.0 C and crystallizes at 40.6 C. It has latent heats of 54.6 and -48.7 J/g for melting and crystallization, respectively. TGA showed that the MEPCM degraded in three distinguishable steps and had good chemical stability. Accelerated thermal cycling tests also indicated that the MEPCM had good thermal reliability. Based on all these results, it can be concluded that the microencapsulated docosane as MEPCMs have good potential for thermal energy storage purposes such as solar space heating applications. (author)

  3. Thermal Management and Thermal Protection Systems

    Science.gov (United States)

    Hasnain, Aqib

    2016-01-01

    During my internship in the Thermal Design Branch (ES3), I contributed to two main projects: i) novel passive thermal management system for future human exploration, ii) AVCOAT undercut thermal analysis. i) As NASA prepares to further expand human and robotic presence in space, it is well known that spacecraft architectures will be challenged with unprecedented thermal environments. Future exploration activities will have the need of thermal management systems that can provide higher reliability, mass and power reduction and increased performance. In an effort to start addressing the current technical gaps the NASA Johnson Space Center Passive Thermal Discipline has engaged in technology development activities. One of these activities was done through an in-house Passive Thermal Management System (PTMS) design for a lunar lander. The proposed PTMS, functional in both microgravity and gravity environments, consists of three main components: a heat spreader, a novel hybrid wick Variable Conductance Heat Pipe (VCHP), and a radiator. The aim of this PTMS is to keep electronics on a vehicle within their temperature limits (0 and 50 C for the current design) during all mission phases including multiple lunar day/night cycles. The VCHP was tested to verify its thermal performance. I created a thermal math model using Thermal Desktop (TD) and analyzed it to predict the PTMS performance. After testing, the test data provided a means to correlate the thermal math model. This correlation took into account conduction and convection heat transfer, representing the actual benchtop test. Since this PTMS is proposed for space missions, a vacuum test will be taking place to provide confidence that the system is functional in space environments. Therefore, the model was modified to include a vacuum chamber with a liquid nitrogen shroud while taking into account conduction and radiation heat transfer. Infrared Lamps were modelled and introduced into the model to simulate the sun

  4. Reliability and main findings of the FEES-Tensilon Test in patients with myasthenia gravis and dysphagia.

    Science.gov (United States)

    Im, Sun; Suntrup-Krueger, Sonja; Colbow, Sigrid; Sauer, Sonja; Claus, Inga; Meuth, Sven G; Dziewas, Rainer; Warnecke, Tobias

    2018-05-26

    Diagnosis of pharyngeal dysphagia caused by myasthenia gravis (MG) based on clinical examination alone is often challenging. Flexible endoscopic evaluation of swallowing (FEES) combined with Tensilon (edrophonium) application, referred to as the FEES-Tensilon Test, was developed to improve diagnostic accuracy and to detect the main symptoms of pharyngeal dysphagia in MG. Here we investigated inter- and intra-rater reliability of the FEES-Tensilon Test and analyzed the main endoscopic findings. Four experienced raters reviewed a total of 20 FEES-Tensilon-Test videos in randomized order. Residue severity was graded at 4 different pharyngeal spaces before and after Tensilon administration. All interpretations were performed twice per rater, 4 weeks apart (a total of 160 scorings). Intra-rater test-retest reliability and inter-rater reliability levels were calculated. The most frequent FEES findings in MG patients before Tensilon application were prominent residues of semi solids spread all over the hypopharynx in varying locations. The reliability level in the interpretation of the FEES-Tensilon test was excellent regardless of the raters' profession or years of experience with FEES. All 4 raters showed high inter- and intra- reliability levels in interpreting the FEES-Tensilon Test based on residue clearance (kappa=0.922, 0.981). Degree of residue normalization in the vallecular space after Tensilon application showed the highest inter- and intra-rater reliability level (kappa=0.863, 0.957) followed by the epiglottis (kappa=0.813, 0.946) and pyriform sinuses (kappa=0.836, 0.929). Interpretation of the FEES-Tensilon Test based on residue severity and degree of Tensilon clearance, especially in the vallecular space, is consistent and reliable. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  5. Intertester reliability of clinical shoulder instability and laxity tests in subjects with and without self-reported shoulder problems.

    Science.gov (United States)

    Eshoj, Henrik; Ingwersen, Kim Gordon; Larsen, Camilla Marie; Kjaer, Birgitte Hougs; Juul-Kristensen, Birgit

    2018-03-03

    First, to investigate the intertester reliability of clinical shoulder instability and laxity tests, and second, to describe the mutual dependency of each test evaluated by each tester for identifying self-reported shoulder instability and laxity. A standardised protocol for conducting reliability studies was used to test the intertester reliability of the six clinical shoulder instability and laxity tests: apprehension, relocation, surprise, load-and-shift, sulcus sign and Gagey. Cohen's kappa (κ) with 95% CIs besides prevalence-adjusted and bias-adjusted kappa (PABAK), accounting for insufficient prevalence and bias, were computed to establish the intertester reliability and mutual dependency. Forty individuals (13 with self-reported shoulder instability and laxity-related shoulder problems and 27 normal shoulder individuals) aged 18-60 were included. Fair (relocation), moderate (load-and-shift, sulcus sign) and substantial (apprehension, surprise, Gagey) intertester reliability were observed across tests (κ 0.39-0.73; 95% CI 0.00 to 1.00). PABAK improved reliability across tests, resulting in substantial to almost perfect intertester reliability for the apprehension, surprise, load-and-shift and Gagey tests (κ 0.65-0.90). Mutual dependencies between each test and self-reported shoulder problem showed apprehension, relocation and surprise to be the most often used tests to characterise self-reported shoulder instability and laxity conditions. Four tests (apprehension, surprise, load-and-shift and Gagey) out of six were considered intertester reliable for clinical use, while relocation and sulcus sign tests need further standardisation before acceptable evidence. Furthermore, the validity of the tests for shoulder instability and laxity needs to be studied. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  6. Reliability and number of trials of Y Balance Test in adolescent athletes.

    Science.gov (United States)

    Linek, Pawel; Sikora, Damian; Wolny, Tomasz; Saulicz, Edward

    2017-10-01

    The Star Excursion Balance Test (SEBT) is commonly used to evaluate dynamic equilibrium. The Y Balance Test (Y-BT) is a shortened version of the SEBT where a Y- Balance Kit is commonly used. To date, research concerning the protocol and reliability of the SEBT and Y-BT has been conducted only for adults. The aim of the study was to assess the protocol (the necessary number of trials to stabilize the results) and reliability of the Y-BT in adolescent athletes. One-way repeated-measures analysis of variance (ANOVA) and reliability study. The sample of 38 athletes (mean age: 15.6 years) was selected from a football club. A Y-Balance test kit was applied for the evaluation of dynamic balance. The analysis used the values normalized to the relative length of the lower limbs. After six attempts, three consecutive ones achieved stability for all directions and both extremities (p > 0.05). The intraclass correlation coefficient (ICC 3,1 ), standard error of measurement and minimal detectable change values for the three attempts ranged from 0.57 to 0.82, from 3 to less than 6% and from 7.68 to 13.7%, respectively. In the study of adolescent dynamic equilibrium using the Y-BT, it is recommended to perform nine attempts (including six trial attempts and three measurements). In order to increase reliability it is recommended that the average of the three measured attempts is analysed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. 3-D CFD modeling and experimental testing of thermal behavior of a Li-Ion battery

    International Nuclear Information System (INIS)

    Gümüşsu, Emre; Ekici, Özgür; Köksal, Murat

    2017-01-01

    Highlights: • A thermally fully predictive 3-D CFD model is developed for Li-Ion batteries. • Complete flow field around the battery and conduction inside the battery are solved. • Macro-scale thermophysical properties and the entropic term are investigated. • Discharge rate and usage history of the battery are systematically investigated. • Reliability of the model was tested through experimental measurements. - Abstract: In this study, a 3-D computational fluid dynamics model was developed for investigating the thermal behavior of lithium ion batteries under natural convection. The model solves the complete flow field around the battery as well as conduction inside the battery using the well-known heat generation model of Bernardi et al. (1985). The model is thermally fully predictive so it requires only electrical performance parameters of the battery to calculate its temperature during discharging. Using the model, detailed investigation of the effects of the variation of the macro-scale thermophysical properties and the entropic term of the heat generation model was carried out. Results show that specific heat is a critical property that has a significant impact on the simulation results whereas thermal conductivity has relatively minor importance. Moreover, the experimental data can be successfully predicted without taking the entropic term into account in the calculation of the heat generation. The difference between the experimental and predicted battery surface temperature was less than 3 °C for all discharge rates and regardless of the usage history of the battery. The developed model has the potential to be used for the investigation of the thermal behavior of Li-Ion batteries in different packaging configurations under natural and forced convection.

  8. Data from thermal testing of the Open Source Cryostage

    DEFF Research Database (Denmark)

    Buch, Johannes Lørup; Ramløv, Hans

    2016-01-01

    The data presented here is related to the research article "An open source cryostage and software analysis method for detection of antifreeze activity" (Buch and Ramløv, 2016) [1]. The design of the Open Source Cryostage (OSC) is tested in terms of thermal limits, thermal efficiency and electrical...... efficiency. This article furthermore includes an overview of the electrical circuitry and a flowchart of the software program controlling the temperature of the OSC. The thermal efficiency data is presented here as degrees per volt and maximum cooling capacity....

  9. Thermal anchoring of wires in large scale superconducting coil test experiment

    International Nuclear Information System (INIS)

    Patel, Dipak; Sharma, A.N.; Prasad, Upendra; Khristi, Yohan; Varmora, Pankaj; Doshi, Kalpesh; Pradhan, S.

    2013-01-01

    Highlights: • We addressed how thermal anchoring in large scale coil test is different compare to small cryogenic apparatus? • We did precise estimation of thermal anchoring length at 77 K and 4.2 K heat sink in large scale superconducting coil test experiment. • We addressed, the quality of anchoring without covering entire wires using Kapton/Teflon tape. • We obtained excellent results in temperature measurement without using GE Varnish by doubling estimated anchoring length. -- Abstract: Effective and precise thermal anchoring of wires in cryogenic experiment is mandatory to measure temperature in milikelvin accuracy and to avoid unnecessary cooling power due to additional heat conduction from room temperature (RT) to operating temperature (OT) through potential, field, displacement and stress measurement instrumentation wires. Instrumentation wires used in large scale superconducting coil test experiments are different compare to cryogenic apparatus in terms of unique construction and overall diameter/area due to errorless measurement in large time-varying magnetic field compare to small cryogenic apparatus, often shielded wires are used. Hence, along with other variables, anchoring techniques and required thermal anchoring length are entirely different in this experiment compare to cryogenic apparatus. In present paper, estimation of thermal anchoring length of five different types of instrumentation wires used in coils test campaign at Institute for Plasma Research (IPR), India has been discussed and some temperature measurement results of coils test campaign have been presented

  10. New design algorithm and reliability testing of solar powered near ...

    African Journals Online (AJOL)

    New design algorithm and reliability testing of solar powered near-space flight vehicle for defense and security. ... To overcome this problem, we propose a pseudo-satellite system where telecommunication devices are carried on a perpetually flying solar aircraft cruising at stratospheric altitude. Our aircraft will combine ...

  11. Improving the Test-Retest Reliability of Resting State fMRI by Removing the Impact of Sleep.

    Science.gov (United States)

    Wang, Jiahui; Han, Junwei; Nguyen, Vinh T; Guo, Lei; Guo, Christine C

    2017-01-01

    Resting state functional magnetic resonance imaging (rs-fMRI) provides a powerful tool to examine large-scale neural networks in the human brain and their disturbances in neuropsychiatric disorders. Thanks to its low demand and high tolerance, resting state paradigms can be easily acquired from clinical population. However, due to the unconstrained nature, resting state paradigm is associated with excessive head movement and proneness to sleep. Consequently, the test-retest reliability of rs-fMRI measures is moderate at best, falling short of widespread use in the clinic. Here, we characterized the effect of sleep on the test-retest reliability of rs-fMRI. Using measures of heart rate variability (HRV) derived from simultaneous electrocardiogram (ECG) recording, we identified portions of fMRI data when subjects were more alert or sleepy, and examined their effects on the test-retest reliability of functional connectivity measures. When volumes of sleep were excluded, the reliability of rs-fMRI is significantly improved, and the improvement appears to be general across brain networks. The amount of improvement is robust with the removal of as much as 60% volumes of sleepiness. Therefore, test-retest reliability of rs-fMRI is affected by sleep and could be improved by excluding volumes of sleepiness as indexed by HRV. Our results suggest a novel and practical method to improve test-retest reliability of rs-fMRI measures.

  12. Molding compound trends in a denser packaging world: Qualification tests and reliability concerns

    Science.gov (United States)

    Nguyen, L. T.; Lo, R. H. Y.; Chen, A. S.; Belani, J. G.

    1993-12-01

    Molding compound development has traditionally been driven by the memory market, then subsequent applications filter down to other IC technologies such as logic, analog, and ASIC. However, this strategy has changed lately with the introduction of thin packages such as PQFP & TSOP. Rather than targeting a compound for a family of IC such as DRAM or SRAM, compound development efforts are now focused at specific classes of packages. The configurations of these thin packages impose new functional requirements that need to be revisited to provide the optimized combination of properties. The evolution of qualification tests mirrors the advances in epoxy and compounding technologies. From the first standard novolac-based epoxies of the 1970s to the latest 3(sup rd)-generation ultra-low stress materials, longer test times at increasingly harsher environments were achieved. This paper benchmarks the current reliability tests used by the electronic industry, examines those tests that affect and are affected by the molding compounds, discusses the relevance of accelerated testing, and addresses the major reliability issues facing current molding compound development efforts. Six compound-related reliability concerns were selected: moldability, package stresses, package cracking, halogen-induced intermetallic growth at bond pads, moisture-induced corrosion, and interfacial delamination. Causes of each failure type are surveyed and remedies are recommended. Accelerated tests are designed to apply to a limited quantity of devices, bias, or environmental conditions larger than usual ratings, to intensify failure mechanisms that would occur under normal operating conditions. The observed behavior is then extrapolated from the lot to the entire population. Emphasis is on compressing the time necessary to obtain reliability data. This approach has two main drawbacks. With increasingly complex devices, even accelerated tests are expensive. And with new technologies, it becomes

  13. Development of a test device to characterize thermal protective performance of fabrics against hot steam and thermal radiation

    International Nuclear Information System (INIS)

    Su, Yun; Li, Jun

    2016-01-01

    Steam burns severely threaten the life of firefighters in the course of their fire-ground activities. The aim of this paper was to characterize thermal protective performance of flame-retardant fabrics exposed to hot steam and low-level thermal radiation. An improved testing apparatus based on ASTM F2731-11 was developed in order to simulate the routine fire-ground conditions by controlling steam pressure, flow rate and temperature of steam box. The thermal protective performance of single-layer and multi-layer fabric system with/without an air gap was studied based on the calibrated tester. It was indicated that the new testing apparatus effectively evaluated thermal properties of fabric in hot steam and thermal radiation. Hot steam significantly exacerbated the skin burn injuries while the condensed water on the skin’s surface contributed to cool down the skin tissues during the cooling. Also, the absorbed thermal energy during the exposure and the cooling was mainly determined by the fabric’s configuration, the air gap size, the exposure time and the existence of hot steam. The research provides a effective method to characterize the thermal protection of fabric in complex conditions, which will help in optimization of thermal protection performance of clothing and reduction of steam burn. (paper)

  14. Development of a valid and reliable test to assess trauma radiograph interpretation performance

    International Nuclear Information System (INIS)

    Neep, M.J.; Steffens, T.; Riley, V.; Eastgate, P.; McPhail, S.M.

    2017-01-01

    Objectives: The purpose of this investigation was to develop and examine the preliminary validity and reliability among radiographers of a test to assess trauma radiograph interpretation performance suitable for use among health professionals. Methods: Stage 1 examined 14,159 consecutive appendicular and axial examinations from a hospital emergency department over a 12 month period to quantify a typical anatomical region case-mix of trauma radiographs. A sample of radiographic cases representative of affected anatomical regions was then developed into the Image Interpretation Test (IIT). Stage 2 involved prospective investigations of the IIT's reliability (inter-rater, intra-rater, internal consistency) and validity (concurrent) among 41 radiographers. Results: The IIT included 60 cases. The median (interquartile range) clinical experience of participants was 5 (2–10) years. Case scores were internally consistent (Cronbach's alpha = 0.90). Favourable inter-rater reliability (kappa > 0.70 for 58/60 cases, Intra-class correlation coefficient (ICC) > 0.99 for total score) and intra-rater reliability (kappa > 0.90 for 60/60 cases, ICC > 0.99 for total score) was observed. There was a positive association between radiographers' confidence in image interpretation and IIT score (coefficient = 1.52, r-squared = 0.60, p < 0.001). Conclusions: The IIT developed during this investigation included a selection of radiographic cases consistent with anatomical regions represented in an adult trauma case-mix. This study has also provided foundational preliminary evidence to support the reliability and validity of the IIT among radiographers. The findings suggest that it is possible to assess image interpretation performance of adult trauma radiographs with this test. - Highlights: • Development of an Image Interpretation Test (IIT). • Cases consistent with anatomical regions represented in a typical adult trauma case-mix. • Development of a

  15. Thermal and fast reactor benchmark testing of ENDF/B-6.4

    International Nuclear Information System (INIS)

    Liu Guisheng

    1999-01-01

    The benchmark testing for B-6.4 was done with the same benchmark experiments and calculating method as for B-6.2. The effective multiplication factors k eff , central reaction rate ratios of fast assemblies and lattice cell reaction rate ratios of thermal lattice cell assemblies were calculated and compared with testing results of B-6.2 and CENDL-2. It is obvious that 238 U data files are most important for the calculations of large fast reactors and lattice thermal reactors. However, 238 U data in the new version of ENDF/B-6 have not been renewed. Only data of 235 U, 27 Al, 14 N and 2 D have been renewed in ENDF/B-6.4. Therefor, it will be shown that the thermal reactor benchmark testing results are remarkably improved and the fast reactor benchmark testing results are not improved

  16. Design and Test of Advanced Thermal Simulators for an Alkali Metal-Cooled Reactor Simulator

    Science.gov (United States)

    Garber, Anne E.; Dickens, Ricky E.

    2011-01-01

    The Early Flight Fission Test Facility (EFF-TF) at NASA Marshall Space Flight Center (MSFC) has as one of its primary missions the development and testing of fission reactor simulators for space applications. A key component in these simulated reactors is the thermal simulator, designed to closely mimic the form and function of a nuclear fuel pin using electric heating. Continuing effort has been made to design simple, robust, inexpensive thermal simulators that closely match the steady-state and transient performance of a nuclear fuel pin. A series of these simulators have been designed, developed, fabricated and tested individually and in a number of simulated reactor systems at the EFF-TF. The purpose of the thermal simulators developed under the Fission Surface Power (FSP) task is to ensure that non-nuclear testing can be performed at sufficiently high fidelity to allow a cost-effective qualification and acceptance strategy to be used. Prototype thermal simulator design is founded on the baseline Fission Surface Power reactor design. Recent efforts have been focused on the design, fabrication and test of a prototype thermal simulator appropriate for use in the Technology Demonstration Unit (TDU). While designing the thermal simulators described in this paper, effort were made to improve the axial power profile matching of the thermal simulators. Simultaneously, a search was conducted for graphite materials with higher resistivities than had been employed in the past. The combination of these two efforts resulted in the creation of thermal simulators with power capacities of 2300-3300 W per unit. Six of these elements were installed in a simulated core and tested in the alkali metal-cooled Fission Surface Power Primary Test Circuit (FSP-PTC) at a variety of liquid metal flow rates and temperatures. This paper documents the design of the thermal simulators, test program, and test results.

  17. Test-retest reliability and sensitivity of the 20-meter walk test among patients with knee osteoarthritis.

    Science.gov (United States)

    Motyl, Jillian M; Driban, Jeffrey B; McAdams, Erica; Price, Lori Lyn; McAlindon, Timothy E

    2013-05-10

    The 20-meter walk test is a physical function measure commonly used in clinical research studies and rehabilitation clinics to measure gait speed and monitor changes in patients' physical function over time. Unfortunately, the reliability and sensitivity of this walk test are not well defined and, therefore, limit our ability to evaluate real changes in gait speed not attributable to normal variability. The aim of this study was to assess the test-restest reliability and sensitivity of the 20-meter walk test, at a self-selected pace, among patients with mild to moderate knee osteoarthritis (OA) and to suggest a standardized protocol for future test administration. This was a measurement reliability study. Fifteen consecutive people enrolled in a randomized-controlled trial of intra-articular corticosteroid injections for knee OA participated in this study. All participants completed 4 trials on 2 separate days, 7 to 21 days apart (8 trials total). Each day was divided into 2 sessions, which each involved 2 walking trials. We compared walk times between trials with Wilcoxon signed-rank tests. Similar analyses compared average walk times between sessions. To confirm these analyses, we also calculated Spearman correlation coefficients to assess the relationship between sessions. Finally, smallest detectable differences (SDD) were calculated to estimate the sensitivity of the 20-meter walk test. Wilcoxon signed-rank tests between trials within the same session demonstrated that trials in session 1 were significantly different and in the subsequent 3 sessions, the median differences between trials were not significantly different. Therefore, the first session of each day was considered a practice session, and the SDD between the second session of each day were calculated. SDD was -1.59 seconds (walking slower) and 0.15 seconds (walking faster). Practice trials and a standardized protocol should be used in administration of the 20-meter walk test. Changes in walk time

  18. Reliability analysis of structures under periodic proof tests in service

    Science.gov (United States)

    Yang, J.-N.

    1976-01-01

    A reliability analysis of structures subjected to random service loads and periodic proof tests treats gust loads and maneuver loads as random processes. Crack initiation, crack propagation, and strength degradation are treated as the fatigue process. The time to fatigue crack initiation and ultimate strength are random variables. Residual strength decreases during crack propagation, so that failure rate increases with time. When a structure fails under periodic proof testing, a new structure is built and proof-tested. The probability of structural failure in service is derived from treatment of all the random variables, strength degradations, service loads, proof tests, and the renewal of failed structures. Some numerical examples are worked out.

  19. Thermal shock test of TiC and graphite

    International Nuclear Information System (INIS)

    Shirakawa, H.; Okamura, J.; Son, P.; Miyake, M.

    1989-01-01

    Thermal shock tests were performed by pulse electron beam heating on chemically vapor deposited coatings of TiC on Poco graphite, bulk TiC, and several kinds of isotropic graphite. The specimens were heated at various power densities (10-45 MW/m 2 ) for various pulse durations (1-2 s) to examine the dependence of thermal failures on heating conditions. The TiC coating on graphite suffered cracking, surface melting and evaporation by the thermal pulse. The surface melting limit, defined as F τ 1/2 , where F is the minimum power density that causes surface melting for a specified pulse duration τ, was approximately 48 MWs 1/2 /m 2 for the TiC coating. The combined-Carbon/Titanium ratio of the coating after electron beam heating decreased with increasing power density and pulse duration. The bulk TiC specimens were so brittle that they fractured at heat load conditions where the coating showed no damage. The graphite specimens showed sublimation as a principal damage mechanism by the thermal pulse, and the sublimation weight loss decreased with increasing the thermal conductivity of the specimen. It was confirmed that the TiC coating on graphite had favorable resistance to thermal shock as compared to the bulk TiC and that graphite with high thermal conductivity is promising material as a high heat flux component. (orig.)

  20. Feasibility and reliability of physical fitness tests in older adults with intellectual disability : A pilot study

    NARCIS (Netherlands)

    Hilgenkamp, Thessa I. M.; van Wijck, Ruud; Evenhuis, Heleen M.

    Background Physical fitness is relevant for wellbeing and health, but knowledge on the feasibility and reliability of instruments to measure physical fitness for older adults with intellectual disability is lacking. Methods Feasibility and test-retest reliability of a physical fitness test battery

  1. Improving the Thermal Testing Technology of Technological Equipment of Autonomous Complexes

    Directory of Open Access Journals (Sweden)

    V. V. Chugunkov

    2017-01-01

    Full Text Available The environmental conditions of autonomous objects of different-purpose technical complexes are in close relationship with increased values of operating temperatures. This requires thermal pretesting of the process equipment. The publication [1] considers the thermal test conditions in which the equipment elements under test are placed in a heated water tank covered by the globe insulators where, under automatic temperature control using a block of heaters, they are then kept for a specified period of time at a specified temperature range. Such an approach to the thermal tests of equipment allows us to reduce, but not eliminate completely the mass flows of water from evaporation with reducing power consumption of test equipment.Despite the results achieved, even a little bit of water vapor available when conducting the thermal tests may cause a failure of equipment. Therefore, there is a need in test equipment modernization for complete eliminating the fluxes of mass water and better power consumption in the test process. To this end, it is proposed to place a three-layer bubble wrap on the open surface of water.To justify an efficiency of the proposed option was developed a mathematical model of heat and mass transfer processes that occur during thermal tests, taking into account the geometric and thermo-physical characteristics of test tank, polymer film, and equipment. Using the laws and equations of heat and mass transfer enabled us to determine the required capacities for heating the tank with water and equipment to the required temperature range for a specified time, as well as the mass flows of water when evaporating from the tank surface.The efficiency of the three-layer bubble film as compared with the globe insulators as the elements for covering the test tank the surface has been analysed on the basis of the results obtained.The proposed film coating allowed almost complete elimination of evaporation losses of water mass and almost 8

  2. Thermal stress mitigation by Active Thermal Control

    DEFF Research Database (Denmark)

    Soldati, Alessandro; Dossena, Fabrizio; Pietrini, Giorgio

    2017-01-01

    This work proposes an Active Thermal Control (ATC) of power switches. Leveraging on the fact that thermal stress has wide impact on the system reliability, controlling thermal transients is supposed to lengthen the lifetime of electronic conversion systems. Indeed in some environments...... results of control schemes are presented, together with evaluation of the proposed loss models. Experimental proof of the ability of the proposed control to reduce thermal swing and related stress on the device is presented, too....

  3. PWR blowdown heat transfer separate-effects program: thermal-hydraulic test facility experimental data report for test 104

    International Nuclear Information System (INIS)

    Leon, D.M.; White, M.D.; Moore, P.A.; Hedrick, R.A.

    1978-01-01

    Reduced instrument responses are presented for Thermal-Hydraulic Test Facility (THTF) test 104, which is part of the ORNL Pressurized-Water Reactor (PWR) Blowdown Heat Transfer Separate-Effects Program. The objective of the program is to investigate the thermal-hydraulic phenomenon governing the energy transfer and transport processes that occur during a loss-of-coolant accident in the PWR system. Test 104 was conducted to obtain CHF in bundle 1 under blowdown conditions. The primary purpose of this report is to make the reduced instrument responses during test 104 available

  4. Reliability analysis applied to structural tests

    Science.gov (United States)

    Diamond, P.; Payne, A. O.

    1972-01-01

    The application of reliability theory to predict, from structural fatigue test data, the risk of failure of a structure under service conditions because its load-carrying capability is progressively reduced by the extension of a fatigue crack, is considered. The procedure is applicable to both safe-life and fail-safe structures and, for a prescribed safety level, it will enable an inspection procedure to be planned or, if inspection is not feasible, it will evaluate the life to replacement. The theory has been further developed to cope with the case of structures with initial cracks, such as can occur in modern high-strength materials which are susceptible to the formation of small flaws during the production process. The method has been applied to a structure of high-strength steel and the results are compared with those obtained by the current life estimation procedures. This has shown that the conventional methods can be unconservative in certain cases, depending on the characteristics of the structure and the design operating conditions. The suitability of the probabilistic approach to the interpretation of the results from full-scale fatigue testing of aircraft structures is discussed and the assumptions involved are examined.

  5. Reliability of 4-meter and 10-meter walk tests after lower extremity surgery.

    Science.gov (United States)

    Unver, Bayram; Baris, Refik Hilmi; Yuksel, Ertugrul; Cekmece, Senol; Kalkan, Serpil; Karatosun, Vasfi

    2017-12-01

    To investigate the test-retest reliability of the 4-meter walk test (4 MWT) and 10-meter walk test (10 MWT) in patients undergoing lower extremity surgery during inpatient rehabilitation. In all, 102 patients with total hip arthroplasty (THA), total knee arthroplasty (TKA), lower extremity fracture (LEF) and soft tissue operation were recruited. Patients performed two 4 MWT and two 10 MWT trials on the same day. The same researcher performed all the measurements to avoid inter-rater variability. The 4 MWT and 10 MWT were shown to have excellent test-retest reliability. The ICCs for the 4 MWT and 10 MWT were found as 0.94 and 0.95, respectively. The SEMs for the 4 MWT and 10 MWT were 2.0 and 5.5 seconds, respectively. The smallest real difference at the 95% confidence level (SRD95) was 5.5 seconds for the 4 MWT and 12.2 seconds for 10 MWT and SRD95 percentage was 31.2 for the 4 MWT and 28.5 for the 10 MWT. Both the 4 MWT and the 10 MWT have excellent reliability in patients undergoing lower extremity surgery such as TKA, THA, LEF and soft tissue operation during inpatient rehabilitation. Clinicians and researchers can be confident that changes above the SRD95s for the different patient groups, for both sexes and with regard to weight-bearing status, represent a real clinical change in rehabilitation process. Implications for Rehabilitation The 4 MWT and the 10 MWT are simple methods and were also shown to be reliable measurement methods in many patient groups. This study illustrates that the test-retest reliability of the 4 MWT and 10 MWT are excellent in patients undergoing lower extremity surgery during inpatient rehabilitation (ICC: 0.94 for 4 MWT, ICC: 0.95 for 10 MWT). Clinicians and researchers can be confident that changes above the SRD95s for the different patient groups, for both sexes and with regard to weight-bearing status represent a real clinical change in rehabilitation process.

  6. Design Evaluation of Thermal-hydraulic Test Facility for a Finned-tube Sodium-to-Air Heat Exchanger

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyungmo; Kim, Byeong-Yeon; Ko, Yung Joo; Cho, Youngil; Kim, Jong-Man; Son, Seok-Kwon; Jo, Youngchul; Kang, Byeong Su; Jung, Minhwan; Eoh, Jaehyuk; Lee, Hyeong-Yeon; Jeong, Ji-Young [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    This paper introduces the recent progress of overall design phase for the SELFA facility and deals with basic thermal-hydraulic design parameters and its design validation as well. For more reliable design of the safety-grade decay heat removal system (DHRS) in PGSFR (Prototype Gen-IV Sodium-cooled Fast Reactor), two kinds of sodium-to-air heat exchangers have been employed in the system as an ultimate heat sink. One is a natural draft sodium-to-air heat exchanger (AHX) with helically-coiled sodium tubes, and the other is a forced draft sodium-to-air heat exchanger (FHX) with finned tubes with a straight-type arranged. Since the FHX is normally operated in an active mode with a forced air draft conditions, its performance should be verified for any anticipated operating conditions. To validate the test section design, evaluations of both thermal-hydraulic and mechanical design have been carried out, and some new concepts or devices were newly employed to replicate the prototypic conditions as closely as possible.

  7. Study of Optimal Perimetric Testing in Children (OPTIC: Feasibility, Reliability and Repeatability of Perimetry in Children.

    Directory of Open Access Journals (Sweden)

    Dipesh E Patel

    Full Text Available To investigate feasibility, reliability and repeatability of perimetry in children.A prospective, observational study recruiting 154 children aged 5-15 years, without an ophthalmic condition that affects the visual field (controls, identified consecutively between May 2012 and November 2013 from hospital eye clinics. Perimetry was undertaken in a single sitting, with standardised protocols, in a randomised order using the Humphrey static (SITA 24-2 FAST, Goldmann and Octopus kinetic perimeters. Data collected included test duration, subjective experience and test quality (incorporating examiner ratings on comprehension of instructions, fatigue, response to visual and auditory stimuli, concentration and co-operation to assess feasibility and reliability. Testing was repeated within 6 months to assess repeatability.Overall feasibility was very high (Goldmann=96.1%, Octopus=89% and Humphrey=100% completed the tests. Examiner rated reliability was 'good' in 125 (81.2% children for Goldmann, 100 (64.9% for Octopus and 98 (63.6% for Humphrey perimetry. Goldmann perimetry was the most reliable method in children under 9 years of age. Reliability improved with increasing age (multinomial logistic regression (Goldmann, Octopus and Humphrey, p<0.001. No significant differences were found for any of the three test strategies when examining initial and follow-up data outputs (Bland-Altman plots, n=43, suggesting good test repeatability, although the sample size may preclude detection of a small learning effect.Feasibility and reliability of formal perimetry in children improves with age. By the age of 9 years, all the strategies used here were highly feasible and reliable. Clinical assessment of the visual field is achievable in children as young as 5 years, and should be considered where visual field loss is suspected. Since Goldmann perimetry is the most effective strategy in children aged 5-8 years and this perimeter is no longer available, further

  8. Testing of High Thermal Cycling Stability of Low Strength Concrete as a Thermal Energy Storage Material

    Directory of Open Access Journals (Sweden)

    Chao Wu

    2016-09-01

    Full Text Available Concrete has the potential to become a solution for thermal energy storage (TES integrated in concentrating solar power (CSP systems due to its good thermal and mechanical properties and low cost of material. In this study, a low strength concrete (C20 is tested at high temperatures up to 600 °C. Specimens are thermally cycled at temperatures in the range of 400–300 °C, 500–300 °C, and 600–300 °C, which TES can reach in operation. For comparison, specimens also cycled at temperature in the range of 400–25 °C (room temperature, 500–25 °C, and 600–25 °C. It is found from the test results that cracks are not observed on the surfaces of concrete specimens until the temperature is elevated up to 500 °C. There is mechanical deterioration of concrete after exposure to high temperature, especially to high thermal cycles. The residual compressive strength of concrete after 10 thermal cycles between 600 °C and 300 °C is about 58.3%, but the specimens remain stable without spalling, indicating possible use of low strength concrete as a TES material.

  9. Test-retest reliability of the driving habits questionnaire in older self-driving adults.

    Science.gov (United States)

    Song, Chiang-Soon; Chun, Byung-Yoon; Chung, Hyun-Sook

    2015-11-01

    [Purpose] The purpose of this study was to investigate the test-retest reliability of the Driving Habits Questionnaire in community-dwelling older self-drivers. [Subjects and Methods] Seventy-four participants were recruited by convenience sampling from local rehabilitation centers. This was a cross-sectional study design that used two clinical measures: the Driving Habits Questionnaire and Mini-mental State Examination. To examine the test-retest reliability of the Driving Habits Questionnaire, the clinical tool was measured twice, five days apart. [Results] The Driving Habits Questionnaire showed good reliability for older community-dwelling self-drivers. The Cronbach's alpha coefficients for the four domains of dependence (0.572), difficulty (0.871), crashes and citations (0.689), and driving space (0.961) of the Driving Habits Questionnaire indicated good or high internal consistency. Driving difficulty correlated significantly with self-reported crashes and citations and driving space. [Conclusion] The results of this study suggest that the Driving Habits Questionnaire is a reliable measure of self-reported interview-based driving behavior in the community-dwelling elderly.

  10. Meeting Human Reliability Requirements through Human Factors Design, Testing, and Modeling

    Energy Technology Data Exchange (ETDEWEB)

    R. L. Boring

    2007-06-01

    In the design of novel systems, it is important for the human factors engineer to work in parallel with the human reliability analyst to arrive at the safest achievable design that meets design team safety goals and certification or regulatory requirements. This paper introduces the System Development Safety Triptych, a checklist of considerations for the interplay of human factors and human reliability through design, testing, and modeling in product development. This paper also explores three phases of safe system development, corresponding to the conception, design, and implementation of a system.

  11. Inter-rater reliability of three standardized functional tests in patients with low back pain

    Science.gov (United States)

    Tidstrand, Johan; Horneij, Eva

    2009-01-01

    Background Of all patients with low back pain, 85% are diagnosed as "non-specific lumbar pain". Lumbar instability has been described as one specific diagnosis which several authors have described as delayed muscular responses, impaired postural control as well as impaired muscular coordination among these patients. This has mostly been measured and evaluated in a laboratory setting. There are few standardized and evaluated functional tests, examining functional muscular coordination which are also applicable in the non-laboratory setting. In ordinary clinical work, tests of functional muscular coordination should be easy to apply. The aim of this present study was to therefore standardize and examine the inter-rater reliability of three functional tests of muscular functional coordination of the lumbar spine in patients with low back pain. Methods Nineteen consecutive individuals, ten men and nine women were included. (Mean age 42 years, SD ± 12 yrs). Two independent examiners assessed three tests: "single limb stance", "sitting on a Bobath ball with one leg lifted" and "unilateral pelvic lift" on the same occasion. The standardization procedure took altered positions of the spine or pelvis and compensatory movements of the free extremities into account. The inter-rater reliability was analyzed by Cohen's kappa coefficient (κ) and by percentage agreement. Results The inter-rater reliability for the right and the left leg respectively was: for the single limb stance very good (κ: 0.88–1.0), for sitting on a Bobath ball good (κ: 0.79) and very good (κ: 0.88) and for the unilateral pelvic lift: good (κ: 0.61) and moderate (κ: 0.47). Conclusion The present study showed good to very good inter-rater reliability for two standardized tests, that is, the single-limb stance and sitting on a Bobath-ball with one leg lifted. Inter-rater reliability for the unilateral pelvic lift test was moderate to good. Validation of the tests in their ability to evaluate lumbar

  12. Inter-rater reliability of three standardized functional tests in patients with low back pain

    Directory of Open Access Journals (Sweden)

    Tidstrand Johan

    2009-06-01

    Full Text Available Abstract Background Of all patients with low back pain, 85% are diagnosed as "non-specific lumbar pain". Lumbar instability has been described as one specific diagnosis which several authors have described as delayed muscular responses, impaired postural control as well as impaired muscular coordination among these patients. This has mostly been measured and evaluated in a laboratory setting. There are few standardized and evaluated functional tests, examining functional muscular coordination which are also applicable in the non-laboratory setting. In ordinary clinical work, tests of functional muscular coordination should be easy to apply. The aim of this present study was to therefore standardize and examine the inter-rater reliability of three functional tests of muscular functional coordination of the lumbar spine in patients with low back pain. Methods Nineteen consecutive individuals, ten men and nine women were included. (Mean age 42 years, SD ± 12 yrs. Two independent examiners assessed three tests: "single limb stance", "sitting on a Bobath ball with one leg lifted" and "unilateral pelvic lift" on the same occasion. The standardization procedure took altered positions of the spine or pelvis and compensatory movements of the free extremities into account. The inter-rater reliability was analyzed by Cohen's kappa coefficient (κ and by percentage agreement. Results The inter-rater reliability for the right and the left leg respectively was: for the single limb stance very good (κ: 0.88–1.0, for sitting on a Bobath ball good (κ: 0.79 and very good (κ: 0.88 and for the unilateral pelvic lift: good (κ: 0.61 and moderate (κ: 0.47. Conclusion The present study showed good to very good inter-rater reliability for two standardized tests, that is, the single-limb stance and sitting on a Bobath-ball with one leg lifted. Inter-rater reliability for the unilateral pelvic lift test was moderate to good. Validation of the tests in their

  13. PWR Blowdown Heat Transfer Separate-Effects Program. Thermal-Hydraulic Test Facility experimental data report for test 166S

    International Nuclear Information System (INIS)

    Clemons, V.D.; White, M.D.; Hedrick, R.A.

    1978-01-01

    Reduced instrument responses are presented for Thermal-Hydraulic Test Facility (THTF) test 166S, which is part of the ORNL Pressurized-Water Reactor (PWR) Blowdown Heat Transfer Separate-Effects Program. The objective of the program is to investigate the thermal-hydraulic phenomenon governing the energy transfer and transport processes that occur during a loss-of-coolant accident in a PWR system. Test 166S was conducted to obtain thermal-hydraulic and CHF information in THTF bundle 1 with an intact hot leg. The primary purpose of this report is to make the reduced instrument responses during tests 166S available. These are presented in graphical form in engineering units and have been analyzed only to the extent necessary to ensure reasonableness and consistency

  14. Seismic stops vs. snubbers, a reliable alternative

    International Nuclear Information System (INIS)

    Cloud, R.L.; Anderson, P.H.; Leung, J.S.M.

    1988-01-01

    The Seismic Stops methodology has been developed to provide a reliable alternative for providing seismic support to nuclear power plant piping. The concept is based on using rigid passive supports with large clearances. These gaps permit unrestrained thermal expansion while limiting excessive seismic displacements. This type of restraint has performed successfully in fossil fueled power plants. A simplified production analysis tool has been developed which evaluates the nonlinear piping response including the effect of the gapped supports. The methodology utilizes the response spectrum approach and has been incorporated into a piping analysis computer program RLCA-GAP. Full scale shake table tests of piping specimens were performed to provide test correlation with the developed methodology. Analyses using RLCA-GAP were in good agreement with test results. A sample piping system was evaluated using the Seismic Stops methodology to replace the existing snubbers with passive gapped supports. To provide further correlation data, the sample system was also evaluated using nonlinear time history analysis. The correlation comparisons showed RLCA-GAP to be a viable methodology and a reliable alternative for snubber optimization and elimination. (orig.)

  15. Improving the Test-Retest Reliability of Resting State fMRI by Removing the Impact of Sleep

    Directory of Open Access Journals (Sweden)

    Jiahui Wang

    2017-05-01

    Full Text Available Resting state functional magnetic resonance imaging (rs-fMRI provides a powerful tool to examine large-scale neural networks in the human brain and their disturbances in neuropsychiatric disorders. Thanks to its low demand and high tolerance, resting state paradigms can be easily acquired from clinical population. However, due to the unconstrained nature, resting state paradigm is associated with excessive head movement and proneness to sleep. Consequently, the test-retest reliability of rs-fMRI measures is moderate at best, falling short of widespread use in the clinic. Here, we characterized the effect of sleep on the test-retest reliability of rs-fMRI. Using measures of heart rate variability (HRV derived from simultaneous electrocardiogram (ECG recording, we identified portions of fMRI data when subjects were more alert or sleepy, and examined their effects on the test-retest reliability of functional connectivity measures. When volumes of sleep were excluded, the reliability of rs-fMRI is significantly improved, and the improvement appears to be general across brain networks. The amount of improvement is robust with the removal of as much as 60% volumes of sleepiness. Therefore, test-retest reliability of rs-fMRI is affected by sleep and could be improved by excluding volumes of sleepiness as indexed by HRV. Our results suggest a novel and practical method to improve test-retest reliability of rs-fMRI measures.

  16. Handling effluent from nuclear thermal propulsion system ground tests

    International Nuclear Information System (INIS)

    Shipers, L.R.; Allen, G.C.

    1992-01-01

    A variety of approaches for handling effluent from nuclear thermal propulsion system ground tests in an environmentally acceptable manner are discussed. The functional requirements of effluent treatment are defined and concept options are presented within the framework of these requirements. System concepts differ primarily in the choice of fission-product retention and waste handling concepts. The concept options considered range from closed cycle (venting the exhaust to a closed volume or recirculating the hydrogen in a closed loop) to open cycle (real time processing and venting of the effluent). This paper reviews the different methods to handle effluent from nuclear thermal propulsion system ground tests

  17. Are chiropractic tests for the lumbo-pelvic spine reliable and valid? A systematic critical literature review

    DEFF Research Database (Denmark)

    Hestbaek, L; Leboeuf-Yde, C

    2000-01-01

    OBJECTIVE: To systematically review the peer-reviewed literature about the reliability and validity of chiropractic tests used to determine the need for spinal manipulative therapy of the lumbo-pelvic spine, taking into account the quality of the studies. DATA SOURCES: The CHIROLARS database......-pelvic spine were included. DATA EXTRACTION: Data quality were assessed independently by the two reviewers, with a quality score based on predefined methodologic criteria. Results of the studies were then evaluated in relation to quality. DATA SYNTHESIS: None of the tests studied had been sufficiently...... evaluated in relation to reliability and validity. Only tests for palpation for pain had consistently acceptable results. Motion palpation of the lumbar spine might be valid but showed poor reliability, whereas motion palpation of the sacroiliac joints seemed to be slightly reliable but was not shown...

  18. Intra-observer and interobserver reliability ofOne Leg Stand Test as a measure of posturalbalance in low back pain patients

    DEFF Research Database (Denmark)

    Maribo, Thomas; Iversen, Elena; Andersen, Niels Trolle

    2009-01-01

    Objective: To determine the absolute and relative reliability of intra-observer and interobserver To determine the absolute and relative reliability of intra-observer and interobserver measurements of postural balance using the One Leg Stand Test in patients with low back pain. Patients and methods...... to stand for the maximum time, and no further analysis was done. Eyes closed: intra-observer reliability was tested in 21 patients; absolute reliability showed a standard error of the measurement (SEM) of 2.48 s and a minimal detectable change (MDC) of 6.88. The relative reliability was acceptable...... with an intra class correlation coefficient (ICC) of 0.86. Interobserver reliability was tested in 27 patients; absolute reliability showed a SEM of 1.42 s and a MDC of 3.95. The relative reliability was acceptable with an ICC of 0.91. Conclusions: The One Leg Stand Test can be used to test postural balance...

  19. FFTF thermal-hydraulic testing results affecting piping and vessel component design in LMFBR's

    International Nuclear Information System (INIS)

    Stover, R.L.; Beaver, T.R.; Chang, S.C.

    1983-01-01

    The Fast Flux Test Facility completed four years of pre-operational testing in April 1982. This paper describes thermal-hydraulic testing results from this period which impact piping and vessel component design in LMFBRs. Data discussed are piping flow oscillations, piping thermal stratification and vessel upper plenum stratification. Results from testing verified that plant design limits were met

  20. Identification of conductive hearing loss using air conduction tests alone: reliability and validity of an automatic test battery.

    Science.gov (United States)

    Convery, Elizabeth; Keidser, Gitte; Seeto, Mark; Freeston, Katrina; Zhou, Dan; Dillon, Harvey

    2014-01-01

    The primary objective of this study was to determine whether a combination of automatically administered pure-tone audiometry and a tone-in-noise detection task, both delivered via an air conduction (AC) pathway, could reliably and validly predict the presence of a conductive component to the hearing loss. The authors hypothesized that performance on the battery of tests would vary according to hearing loss type. A secondary objective was to evaluate the reliability and validity of a novel automatic audiometry algorithm to assess its suitability for inclusion in the test battery. Participants underwent a series of hearing assessments that were conducted in a randomized order: manual pure-tone air conduction audiometry and bone conduction audiometry; automatic pure-tone air conduction audiometry; and an automatic tone-in-noise detection task. The automatic tests were each administered twice. The ability of the automatic test battery to: (a) predict the presence of an air-bone gap (ABG); and (b) accurately measure AC hearing thresholds was assessed against the results of manual audiometry. Test-retest conditions were compared to determine the reliability of each component of the automatic test battery. Data were collected on 120 ears from normal-hearing and conductive, sensorineural, and mixed hearing-loss subgroups. Performance differences between different types of hearing loss were observed. Ears with a conductive component (conductive and mixed ears) tended to have normal signal to noise ratios (SNR) despite impaired thresholds in quiet, while ears without a conductive component (normal and sensorineural ears) demonstrated, on average, an increasing relationship between their thresholds in quiet and their achieved SNR. Using the relationship between these two measures among ears with no conductive component as a benchmark, the likelihood that an ear has a conductive component can be estimated based on the deviation from this benchmark. The sensitivity and

  1. Publishing nutrition research: validity, reliability, and diagnostic test assessment in nutrition-related research.

    Science.gov (United States)

    Gleason, Philip M; Harris, Jeffrey; Sheean, Patricia M; Boushey, Carol J; Bruemmer, Barbara

    2010-03-01

    This is the sixth in a series of monographs on research design and analysis. The purpose of this article is to describe and discuss several concepts related to the measurement of nutrition-related characteristics and outcomes, including validity, reliability, and diagnostic tests. The article reviews the methodologic issues related to capturing the various aspects of a given nutrition measure's reliability, including test-retest, inter-item, and interobserver or inter-rater reliability. Similarly, it covers content validity, indicators of absolute vs relative validity, and internal vs external validity. With respect to diagnostic assessment, the article summarizes the concepts of sensitivity and specificity. The hope is that dietetics practitioners will be able to both use high-quality measures of nutrition concepts in their research and recognize these measures in research completed by others. Copyright 2010 American Dietetic Association. Published by Elsevier Inc. All rights reserved.

  2. Behaviour of Ti-doped CFCs under thermal fatigue tests

    Energy Technology Data Exchange (ETDEWEB)

    Centeno, A. [Instituto Nacional del Carbon (CSIC), Apdo. 73, 33080 Oviedo (Spain); Pintsuk, G.; Linke, J. [Forschungszentrum Juelich GmbH, EURATOM Association, 52425 Juelich (Germany); Gualco, C. [Ansaldo Energia, I-16152 Genoa (Italy); Blanco, C., E-mail: clara@incar.csic.es [Instituto Nacional del Carbon (CSIC), Apdo. 73, 33080 Oviedo (Spain); Santamaria, R.; Granda, M.; Menendez, R. [Instituto Nacional del Carbon (CSIC), Apdo. 73, 33080 Oviedo (Spain)

    2011-01-15

    In spite of the remarkable progress in the design of in-vessel components for the divertor of the first International Thermonuclear Experimental Reactor (ITER), a great effort is still put into the development of manufacturing technologies for carbon armour with improved properties. Newly developed 3D titanium-doped carbon fibre reinforced composites and their corresponding undoped counterparts were brazed to a CuCrZr heat sink to produce actively cooled flat tile mock-ups. By exposing the mock-ups to thermal fatigue tests in an electron beam test facility, the material behaviour and the brazing between the individual constituents in the mock-up was qualified. The mock-ups with titanium-doped CFCs exhibited a significantly improved thermal fatigue resistance compared with those undoped materials. The comparison of these mock-ups with those produced using pristine NB31, one of the reference materials as plasma facing material for ITER, showed almost identical results, indicating the high potential of Ti-doped CFCs due to their improved thermal shock resistance.

  3. Assessment of microelectronics packaging for high temperature, high reliability applications

    Energy Technology Data Exchange (ETDEWEB)

    Uribe, F.

    1997-04-01

    This report details characterization and development activities in electronic packaging for high temperature applications. This project was conducted through a Department of Energy sponsored Cooperative Research and Development Agreement between Sandia National Laboratories and General Motors. Even though the target application of this collaborative effort is an automotive electronic throttle control system which would be located in the engine compartment, results of this work are directly applicable to Sandia`s national security mission. The component count associated with the throttle control dictates the use of high density packaging not offered by conventional surface mount. An enabling packaging technology was selected and thermal models defined which characterized the thermal and mechanical response of the throttle control module. These models were used to optimize thick film multichip module design, characterize the thermal signatures of the electronic components inside the module, and to determine the temperature field and resulting thermal stresses under conditions that may be encountered during the operational life of the throttle control module. Because the need to use unpackaged devices limits the level of testing that can be performed either at the wafer level or as individual dice, an approach to assure a high level of reliability of the unpackaged components was formulated. Component assembly and interconnect technologies were also evaluated and characterized for high temperature applications. Electrical, mechanical and chemical characterizations of enabling die and component attach technologies were performed. Additionally, studies were conducted to assess the performance and reliability of gold and aluminum wire bonding to thick film conductor inks. Kinetic models were developed and validated to estimate wire bond reliability.

  4. Evaluation of accelerated UV and thermal testing for benzene formation in beverages containing benzoate and ascorbic acid.

    Science.gov (United States)

    Nyman, Patricia J; Wamer, Wayne G; Begley, Timothy H; Diachenko, Gregory W; Perfetti, Gracia A

    2010-04-01

    Under certain conditions, benzene can form in beverages containing benzoic and ascorbic acids. The American Beverage Assn. (ABA) has published guidelines to help manufacturers mitigate benzene formation in beverages. These guidelines recommend accelerated testing conditions to test product formulations, because exposure to ultraviolet (UV) light and elevated temperature over the shelf life of the beverage may result in benzene formation in products containing benzoic and ascorbic acids. In this study, the effects of UVA exposure on benzene formation were determined. Benzene formation was examined for samples contained in UV stabilized and non-UV stabilized packaging. Additionally, the usefulness of accelerated thermal testing to simulate end of shelf-life benzene formation was evaluated for samples containing either benzoic or ascorbic acid, or both. The 24 h studies showed that under intense UVA light benzene levels increased by as much as 53% in model solutions stored in non-UV stabilized bottles, whereas the use of UV stabilized polyethylene terephthalate bottles reduced benzene formation by about 13% relative to the non-UV stabilized bottles. Similar trends were observed for the 7 d study. Retail beverages and positive and negative controls were used to study the accelerated thermal testing conditions. The amount of benzene found in the positive controls and cranberry juice suggests that testing at 40 degrees C for 14 d may more reliably simulate end of shelf-life benzene formation in beverages. Except for cranberry juice, retail beverages were not found to contain detectable amounts of benzene (<0.05 ng/g) at the end of their shelf lives.

  5. Test-retest reliability of the 20-sec Wingate test to assess anaerobic power in children with cerebral palsy

    NARCIS (Netherlands)

    Dallmeijer, A.J.; Scholtes, V.A.B.; Brehm, M.A.; Becher, J.G.

    2013-01-01

    OBJECTIVE: The aim of this study was to determine the test-retest reliability of the 20-sec Wingate anaerobic test in children with cerebral palsy. DESIGN: Participants were 22 ambulant children with cerebral palsy, with Gross Motor Function Classification System levels I (limitations in advanced

  6. Test-Retest Reliability of the 20-sec Wingate Test to Assess Anaerobic Power in Children with Cerebral Palsy

    NARCIS (Netherlands)

    Dallmeijer, Annet J.; Scholtes, Vanessa A. B.; Brehm, Merel-Anne; Becher, Jules G.

    2013-01-01

    Objective: The aim of this study was to determine the test-retest reliability of the 20-sec Wingate anaerobic test in children with cerebral palsy. Design: Participants were 22 ambulant children with cerebral palsy, with Gross Motor Function Classification System levels I (limitations in advanced

  7. Thermal performance test for steam turbine of nuclear power plants

    International Nuclear Information System (INIS)

    Bu Yubing; Xu Zongfu; Wang Shiyong

    2014-01-01

    Through study of steam turbine thermal performance test of CPR1000 nuclear power plant, we solve the enthalpy calculation problems of the steam turbine in wet steam zone using heat balance method which can help to figure out the real overall heat balance diagram for the first time, and we develop a useful software for thermal heat balance calculation. Ling'ao phase II as an example, this paper includes test instrument layout, system isolation, risk control, data acquisition, wetness measurement, heat balance calculation, etc. (authors)

  8. International Space Station Active Thermal Control Sub-System On-Orbit Pump Performance and Reliability Using Liquid Ammonia as a Coolant

    Science.gov (United States)

    Morton, Richard D.; Jurick, Matthew; Roman, Ruben; Adamson, Gary; Bui, Chinh T.; Laliberte, Yvon J.

    2011-01-01

    The International Space Station (ISS) contains two Active Thermal Control Sub-systems (ATCS) that function by using a liquid ammonia cooling system collecting waste heat and rejecting it using radiators. These subsystems consist of a number of heat exchangers, cold plates, radiators, the Pump and Flow Control Subassembly (PFCS), and the Pump Module (PM), all of which are Orbital Replaceable Units (ORU's). The PFCS provides the motive force to circulate the ammonia coolant in the Photovoltaic Thermal Control Subsystem (PVTCS) and has been in operation since December, 2000. The Pump Module (PM) circulates liquid ammonia coolant within the External Active Thermal Control Subsystem (EATCS) cooling the ISS internal coolant (water) loops collecting waste heat and rejecting it through the ISS radiators. These PM loops have been in operation since December, 2006. This paper will discuss the original reliability analysis approach of the PFCS and Pump Module, comparing them against the current operational performance data for the ISS External Thermal Control Loops.

  9. Hall Thruster Thermal Modeling and Test Data Correlation

    Science.gov (United States)

    Myers, James; Kamhawi, Hani; Yim, John; Clayman, Lauren

    2016-01-01

    The life of Hall Effect thrusters are primarily limited by plasma erosion and thermal related failures. NASA Glenn Research Center (GRC) in cooperation with the Jet Propulsion Laboratory (JPL) have recently completed development of a Hall thruster with specific emphasis to mitigate these limitations. Extending the operational life of Hall thursters makes them more suitable for some of NASA's longer duration interplanetary missions. This paper documents the thermal model development, refinement and correlation of results with thruster test data. Correlation was achieved by minimizing uncertainties in model input and recognizing the relevant parameters for effective model tuning. Throughout the thruster design phase the model was used to evaluate design options and systematically reduce component temperatures. Hall thrusters are inherently complex assemblies of high temperature components relying on internal conduction and external radiation for heat dispersion and rejection. System solutions are necessary in most cases to fully assess the benefits and/or consequences of any potential design change. Thermal model correlation is critical since thruster operational parameters can push some components/materials beyond their temperature limits. This thruster incorporates a state-of-the-art magnetic shielding system to reduce plasma erosion and to a lesser extend power/heat deposition. Additionally a comprehensive thermal design strategy was employed to reduce temperatures of critical thruster components (primarily the magnet coils and the discharge channel). Long term wear testing is currently underway to assess the effectiveness of these systems and consequently thruster longevity.

  10. Reliability of Autism-Tics, AD/HD, and other Comorbidities (A-TAC) inventory in a test-retest design.

    Science.gov (United States)

    Larson, Tomas; Kerekes, Nóra; Selinus, Eva Norén; Lichtenstein, Paul; Gumpert, Clara Hellner; Anckarsäter, Henrik; Nilsson, Thomas; Lundström, Sebastian

    2014-02-01

    The Autism-Tics, AD/HD, and other Comorbidities (A-TAC) inventory is used in epidemiological research to assess neurodevelopmental problems and coexisting conditions. Although the A-TAC has been applied in various populations, data on retest reliability are limited. The objective of the present study was to present additional reliability data. The A-TAC was administered by lay assessors and was completed on two occasions by parents of 400 individual twins, with an average interval of 70 days between test sessions. Intra- and inter-rater reliability were analysed with intraclass correlations and Cohen's kappa. A-TAC showed excellent test-retest intraclass correlations for both autism spectrum disorder and attention deficit hyperactivity disorder (each at .84). Most modules in the A-TAC had intra- and inter-rater reliability intraclass correlation coefficients of > or = .60. Cohen's kappa indi- cated acceptable reliability. The current study provides statistical evidence that the A-TAC yields good test-retest reliability in a population-based cohort of children.

  11. Reliability engineering

    International Nuclear Information System (INIS)

    Lee, Chi Woo; Kim, Sun Jin; Lee, Seung Woo; Jeong, Sang Yeong

    1993-08-01

    This book start what is reliability? such as origin of reliability problems, definition of reliability and reliability and use of reliability. It also deals with probability and calculation of reliability, reliability function and failure rate, probability distribution of reliability, assumption of MTBF, process of probability distribution, down time, maintainability and availability, break down maintenance and preventive maintenance design of reliability, design of reliability for prediction and statistics, reliability test, reliability data and design and management of reliability.

  12. Pitfalls and important issues in testing reliability using intraclass correlation coefficients in orthopaedic research.

    Science.gov (United States)

    Lee, Kyoung Min; Lee, Jaebong; Chung, Chin Youb; Ahn, Soyeon; Sung, Ki Hyuk; Kim, Tae Won; Lee, Hui Jong; Park, Moon Seok

    2012-06-01

    Intra-class correlation coefficients (ICCs) provide a statistical means of testing the reliability. However, their interpretation is not well documented in the orthopedic field. The purpose of this study was to investigate the use of ICCs in the orthopedic literature and to demonstrate pitfalls regarding their use. First, orthopedic articles that used ICCs were retrieved from the Pubmed database, and journal demography, ICC models and concurrent statistics used were evaluated. Second, reliability test was performed on three common physical examinations in cerebral palsy, namely, the Thomas test, the Staheli test, and popliteal angle measurement. Thirty patients were assessed by three orthopedic surgeons to explore the statistical methods testing reliability. Third, the factors affecting the ICC values were examined by simulating the data sets based on the physical examination data where the ranges, slopes, and interobserver variability were modified. Of the 92 orthopedic articles identified, 58 articles (63%) did not clarify the ICC model used, and only 5 articles (5%) described all models, types, and measures. In reliability testing, although the popliteal angle showed a larger mean absolute difference than the Thomas test and the Staheli test, the ICC of popliteal angle was higher, which was believed to be contrary to the context of measurement. In addition, the ICC values were affected by the model, type, and measures used. In simulated data sets, the ICC showed higher values when the range of data sets were larger, the slopes of the data sets were parallel, and the interobserver variability was smaller. Care should be taken when interpreting the absolute ICC values, i.e., a higher ICC does not necessarily mean less variability because the ICC values can also be affected by various factors. The authors recommend that researchers clarify ICC models used and ICC values are interpreted in the context of measurement.

  13. Reliability of a functional test battery evaluating functionality, proprioception, and strength in recreational athletes with functional ankle instability.

    Science.gov (United States)

    Sekir, U; Yildiz, Y; Hazneci, B; Ors, F; Saka, T; Aydin, T

    2008-12-01

    In contrast to the single evaluation methods used in the past, the combination of multiple tests allows one to obtain a global assessment of the ankle joint. The aim of this study was to determine the reliability of the different tests in a functional test battery. Twenty-four male recreational athletes with unilateral functional ankle instability (FAI) were recruited for this study. One component of the test battery included five different functional ability tests. These tests included a single limb hopping course, single-legged and triple-legged hop for distance, and six and cross six meter hop for time. The ankle joint position sense and one leg standing test were used for evaluation of proprioception and sensorimotor control. The isokinetic strengths of the ankle invertor and evertor muscles were evaluated at a velocity of 120 degrees /s. The reliability of the test battery was assessed by calculating the intraclass correlation coefficient (ICC). Each subject was tested two times, with an interval of 3-5 days between the test sessions. The ICCs for ankle functional and proprioceptive ability showed high reliability (ICCs ranging from 0.94 to 0.98). Additionally, isokinetic ankle joint inversion and eversion strength measurements represented good to high reliability (ICCs between 0.82 and 0.98). The functional test battery investigated in this study proved to be a reliable tool for the assessment of athletes with functional ankle instability. Therefore, clinicians may obtain reliable information from the functional test battery during the assessment of ankle joint performance in patients with functional ankle instability.

  14. Development, construct validity and test-retest reliability of a field-based wheelchair mobility performance test for wheelchair basketball

    NARCIS (Netherlands)

    de Witte, Annemarie M. H.; Hoozemans, Marco J. M.; Berger, Monique A. M.; van der Slikke, Rienk M. A.; van der Woude, Lucas H. V.; Veeger, Dirkjan (H. E. J)

    2018-01-01

    The aim of this study was to develop and describe a wheelchair mobility performance test in wheelchair basketball and to assess its construct validity and reliability. To mimic mobility performance of wheelchair basketball matches in a standardised manner, a test was designed based on observation of

  15. Reliability of Autonomic Responses and Malaise Across Multiple Motion Sickness Stimulation Tests

    Science.gov (United States)

    Stout, Cynthia S.; Toscano, William B.; Cowings, Patricia S.

    1993-01-01

    There is general agreement that a high degree of variability exists between subjects in their autonomic nervous system responses to motion sickness stimulation. Additionally, a paucity of data exists that examines the variability within an individual across repeated motion sickness tests. Investigators have also examined the relationship of autonomic responses to motion sickness development. These investigations have used analyses at discrete points in time to describe this relationship. This approach fails to address the time course of autonomic responses and malaise development throughout the motion sickness test. Our objectives were to examine the reliability of autonomic responses and malaise using the final minute of the motion sickness test across five testing occasions, to examine the reliability of the change in autonomic responses and the change in malaise across five testing occasions, and to examine the relationship between changes in autonomic responses and changes in malaise level across the entire motion sickness test. Our results indicate that, based on the final minute of testing, the autonomic responses of heart rate, blood volume pulse, and respiration rate are moderately stable across multiple tests. Changes in heart rate, blood volume pulse, respiration rate, and malaise throughout the test duration were less stable across the tests. We attribute this instability to variations in individual susceptibility and the error associated with estimating a measure of autonomic gain.

  16. Full-size solar dynamic heat receiver thermal-vacuum tests

    Science.gov (United States)

    Sedgwick, L. M.; Kaufmann, K. J.; Mclallin, K. L.; Kerslake, T. W.

    1991-01-01

    The testing of a full-size, 102 kW, solar dynamic heat receiver utilizing high-temperature thermal energy storage is described. The purpose of the test program was to quantify receiver thermodynamic performance, operating temperatures, and thermal response to changes in environmental and power module interface boundary conditions. The heat receiver was tested in a vacuum chamber with liquid nitrogen cold shrouds and an aperture cold plate to partly simulate a low-Earth-orbit environment. The cavity of the receiver was heated by an infrared quartz lamp heater with 30 independently controllable zones to allow axially and circumferentially varied flux distributions. A closed-Brayton cycle engine simulator conditioned a helium-xenon gas mixture to specific interface conditions to simulate the various operational modes of the solar dynamic power module on the Space Station Freedom. Inlet gas temperature, pressure, and flow rate were independently varied. A total of 58 simulated orbital cycles, each 94 minutes in duration, was completed during the test period.

  17. Reliability, Validity and Factor Structure of Drug Abuse Screening Test

    Directory of Open Access Journals (Sweden)

    Sayed Hadi Sayed Alitabar

    2016-05-01

    Full Text Available Background and Objective: According to the increasing of substance use in the country, more researches about this phenomenon are necessary. This Study Investigates the Validity, Reliability and Confirmatory Factor Structure of the Drug Abuse Screening test (DAST. Materials and Methods: The Sample Consisted of 381 Patients (143 Women and 238 Men with a Multi-Stage Cluster Sampling of Areas 2, 6 and 12 of Tehran Were Selected from Each Region, 6 Randomly Selected Drug Rehabilitation Center. The DAST Was Used as Instrument. Divergent & Convergent Validity of this Scale Was Assessed with Problems Assessment for Substance Using Psychiatric Patients (PASUPP and Relapse Prediction Scale (RPS.Results: The DAST after the First Time Factor Structure of Using Confirmatory Factor Analysis Was Confirmed. The DAST Had a Good Internal Consistency (Cranach’s Alpha, and the Reliability of the Test Within a Week, 0.9, 0.8. Also this Scale Had a Positive Correlation with Problems Assessment for Substance Using Psychiatric Patients and Relapse Prediction Scale (P<0.01.Conclusion: The Overall Results Showed that the Drug Abuse Screening Test in Iranian Society Is Valid. It Can Be Said that Self-Report Scale Tool Is Useful for Research Purposes and Addiction.

  18. Design for reliability of solid state lighting systems

    NARCIS (Netherlands)

    Perpiñà, X.; Werkhoven, R.J.; Jakovenko, J.; Formánek, J.; Vellvehi, M.; Jordà, X.; Kunen, J.M.G.; Bancken, P.; Bolt, P.J.

    2012-01-01

    This work presents a methodology to design an SSL system for reliability. An LED lamp is thermally characterised and its model thermally simulated, indicating that the LED board (FR4 board with thermal vias, copper tracks and LED package) is the thermally most stressed part. Therefore, a

  19. Thermal Testing Methods for Solar Dryers

    DEFF Research Database (Denmark)

    Singh, Shobhana

    2017-01-01

    Solar food drying is a complex heat and mass transfer phenomena which depend on a number of drying process-dependent parameters such as operating conditions and characteristics of the food product to be dried. The variation in these parameters significantly affects the overall performance...... of the dryer system. Since commercial growth and acceptance of any solar dryer system momentously depend on its performance guarantee, the development of a standard methodology for their thermal testing has become necessary. The standard testing method not only provides better performance management...... of the dryer system but allows the manufacturers to achieve competitive efficiency and good product quality by comparing the available designs. In this chapter, an extensive review of solar dryer performance evaluation has been carried out. Furthermore, the chapter describes the existing testing procedures...

  20. Performance testing of thermal analysis codes for nuclear fuel casks

    International Nuclear Information System (INIS)

    Sanchez, L.C.

    1987-01-01

    In 1982 Sandia National Laboratories held the First Industry/Government Joint Thermal and Structural Codes Information Exchange and presented the initial stages of an investigation of thermal analysis computer codes for use in the design of nuclear fuel shipping casks. The objective of the investigation was to (1) document publicly available computer codes, (2) assess code capabilities as determined from their user's manuals, and (3) assess code performance on cask-like model problems. Computer codes are required to handle the thermal phenomena of conduction, convection and radiation. Several of the available thermal computer codes were tested on a set of model problems to assess performance on cask-like problems. Solutions obtained with the computer codes for steady-state thermal analysis were in good agreement and the solutions for transient thermal analysis differed slightly among the computer codes due to modeling differences