WorldWideScience

Sample records for thermal energy saving

  1. Potential energy savings and thermal comfort

    DEFF Research Database (Denmark)

    Jensen, Karsten Ingerslev; Rudbeck, Claus Christian; Schultz, Jørgen Munthe

    1996-01-01

    The simulation results on the energy saving potential and influence on indoor thermal comfort by replacement of common windows with aerogel windows as well as commercial low-energy windows are described and analysed.......The simulation results on the energy saving potential and influence on indoor thermal comfort by replacement of common windows with aerogel windows as well as commercial low-energy windows are described and analysed....

  2. Potential energy savings and thermal comfort

    DEFF Research Database (Denmark)

    Jensen, Karsten Ingerslev; Rudbeck, Claus Christian; Schultz, Jørgen Munthe

    1996-01-01

    Results of simulations carried out on four different buildings with common windows, commercial low-energy windows and xerogel windows are presented. The results are the annual energy consumption for space heating and the indoor air temperature level.......Results of simulations carried out on four different buildings with common windows, commercial low-energy windows and xerogel windows are presented. The results are the annual energy consumption for space heating and the indoor air temperature level....

  3. ENERGY SAVINGS POTENTIALS IN RESIDENTIAL AND SMALL COMMERCIAL THERMAL DISTRIBUTION SYSTEMS - AN UPDATE

    Energy Technology Data Exchange (ETDEWEB)

    ANDREWS,J.W.

    2003-10-31

    This is an update of a report (Andrews and Modera 1991) that quantified the amounts of energy that could be saved through better thermal distribution systems in residential and small commercial buildings. Thermal distribution systems are the ductwork, piping, or other means used to transport heat or cooling from the space-conditioning equipment to the conditioned space. This update involves no basic change in methodology relative to the 1991 report, but rather a review of the additional information available in 2003 on the energy-use patterns in residential and small commercial buildings.

  4. Solar thermal technology development: Estimated market size and energy cost savings. Volume 1: Executive summary

    Science.gov (United States)

    Gates, W. R.

    1983-02-01

    Estimated future energy cost savings associated with the development of cost-competitive solar thermal technologies (STT) are discussed. Analysis is restricted to STT in electric applications for 16 high-insolation/high-energy-price states. The fuel price scenarios and three 1990 STT system costs are considered, reflecting uncertainty over future fuel prices and STT cost projections. STT R&D is found to be unacceptably risky for private industry in the absence of federal support. Energy cost savings were projected to range from $0 to $10 billion (1990 values in 1981 dollars), dependng on the system cost and fuel price scenario. Normal R&D investment risks are accentuated because the Organization of Petroleum Exporting Countries (OPEC) cartel can artificially manipulate oil prices and undercut growth of alternative energy sources. Federal participation in STT R&D to help capture the potential benefits of developing cost-competitive STT was found to be in the national interest.

  5. Analysis of Energy Saving Potential and Optimization of Thermally Broken Fiberglass Window Frames

    DEFF Research Database (Denmark)

    Zajas, Jan Jakub; Heiselberg, Per

    2011-01-01

    of a window frame can be significantly reduced by these means. Performance of an actual fiberglass frame optimized in this work is significantly improved, but still not competitive against state of the art frames. This indicates that more drastic improvements need to be done in order to achieve satisfying......This paper elaborates on the energy saving potential and development process of fiberglass window frames, with intention for application in cold climates. A method is presented, where different means of improving thermal performance of a window frame are evaluated. Firstly, very simple geometries...

  6. Photovoltaic Greenhouses: Comparison of Optical and Thermal Behaviour for Energy Savings

    Directory of Open Access Journals (Sweden)

    Maurizio Carlini

    2012-01-01

    Full Text Available The production of energy from renewable sources, the diversification of the productive activities, and the development of photovoltaic technology and integrated systems have led to the development of solar greenhouses. The interest of the developers and designers is now to seek new approaches to combine the electricity and food production optimally. The interaction of factors as outside local climate, exposure, slope, soil, altitude, wind conditions, structural materials, or cultivated plant species, influences greatly the energy balance. This paper illustrates the comparison of optical and thermal behavior of a solar greenhouse and a similar glass greenhouse, devoted to the production of soil-less tomatoes in three different Italian areas, with computational aspects and methods of the TRNSYS simulation. Values of climatic parameters are obtained as a responce for the feasibility of the cultivation under PV modules. The results show energy savings both for heating and cooling due to PV panels, adding a new reason for the realization of these systems.

  7. Potential energy savings

    DEFF Research Database (Denmark)

    Schultz, Jørgen Munthe

    1996-01-01

    This chapter describes the chosen methods for estimating the potential energy savings if ordinary window glazing is exchanged with aerogel glazing as well as commercial low-energy glazings.......This chapter describes the chosen methods for estimating the potential energy savings if ordinary window glazing is exchanged with aerogel glazing as well as commercial low-energy glazings....

  8. Energy saving report; Energispareredegoerelse

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-05-01

    Making the energy consumption more efficient in Denmark by means of energy saving are connected to the Danish government's overall National Growth Strategy. A reduced consumption of energy as a result of economic attractive energy saving initiatives leads to reduced energy costs and consequently an improvement of Denmark's competitive power. Furthermore, reducing the energy consumption decreases the vulnerability towards rising energy prices, and the security of supplies is increased. Finally energy conservation serves as a means of reducing environmental impact from the energy sector. Energy consumption is not damaging to the environment in itself, however, to the extent that energy consumption causes negative impact on the environment, e.g. through discharge of environmentally damaging substances generated during energy production, a reduction of the energy consumption will benefit the environment. Energy saving in itself does not lead to a decrease in CO{sub 2} emission in Denmark unless it is accompanied by an adjustment of CO{sub 2} quotas on production of electricity. The Danish Government emphasizes that the energy saving efforts are cost-effective both for the society and for the consumers. The energy saving report contains an updated projection of the Danish energy consumption and an evaluation of the impacts of the energy saving efforts. The impacts of more effective end use of energy are described, and an account of the barriers preventing the realization of a number of potential economic attractive energy saving initiatives is made. Finally the energy saving report presents a number of proposals for new energy saving initiatives. (BA)

  9. Plugging into Energy Savings.

    Science.gov (United States)

    Harrigan, Merrilee

    1999-01-01

    The nonprofit Alliance to Save Energy has been helping schools reduce energy consumption through a combination of retrofits, classroom instruction, and behavior. Lists eight small steps to big energy savings, among them: involve the whole school, stop leaks, turn off computers, and recycle. (MLF)

  10. Annual Energy Savings and Thermal Comfort of Autonomously Heated and Cooled Office Chairs

    Energy Technology Data Exchange (ETDEWEB)

    Carmichael, Scott [National Renewable Energy Lab. (NREL), Golden, CO (United States); Booten, Chuck [National Renewable Energy Lab. (NREL), Golden, CO (United States); Robertson, Joseph [National Renewable Energy Lab. (NREL), Golden, CO (United States); Chin, Justin [National Renewable Energy Lab. (NREL), Golden, CO (United States); Christensen, Dane [National Renewable Energy Lab. (NREL), Golden, CO (United States); Pless, Jacquelyn [National Renewable Energy Lab. (NREL), Golden, CO (United States); Arent, Doug [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-07-01

    Energy use in offices buildings is largely driven by air conditioning demands. But the optimal temperature is not the same for all building occupants, leading to the infamous thermostat war. And many occupants have independently overcome building comfort weaknesses with their own space heaters or fans. NREL tested is a customized office chair that automatically heats and cools the occupant along the seat and chair back according to the occupants' personal preferences. This product is shown to deliver markedly better comfort at room temperatures well above typical office cooling setpoints. Experimental subjects reported satisfaction in these elevated air temperatures, partly because the chair's cooling effect was tuned to their own individual needs. Simulation of the chair in office buildings around the U.S. shows that energy can be saved everywhere, with impacts varying due to the climate. Total building HVAC energy savings exceeded 10% in hot-dry climate zones. Due to high product cost, simple payback for the chair we studied is beyond the expected chair life. We then understood the need to establish cost-performance targets for comfort delivery packages. NREL derived several hypothetical energy/cost/comfort targets for personal comfort product systems. In some climate regions around the U.S., these show the potential for office building HVAC energy savings in excess of 20%. This report documents this research, providing an overview of the research team's methods and results while also identifying areas for future research building upon the findings.

  11. A heating agent using a personalised thermal comfort model to Save energy

    OpenAIRE

    Auffenberg, Frederik; Stein, Sebastian; Rogers, Alex

    2015-01-01

    We present a novel, personalised thermal comfort model anda heating agent using this model to reduce energy consump-tion with minimal comfort loss. At present, heating agentstypically use simple models of user comfort when decidingon a set point temperature for the heating or cooling system.These models however generally fail to adapt to an individ-ual user's preferences, resulting in poor performance. Toaddress this issue, we propose a personalised thermal com-fort model using a Bayesian net...

  12. Energy Savings Lifetimes and Persistence

    Energy Technology Data Exchange (ETDEWEB)

    Hoffman, Ian M. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Schiller, Steven R. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Todd, Annika [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Billingsley, Megan A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Goldman, Charles A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Schwartz, Lisa C. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-02-01

    This technical brief explains the concepts of energy savings lifetimes and savings persistence and discusses how program administrators use these factors to calculate savings for efficiency measures, programs and portfolios. Savings lifetime is the length of time that one or more energy efficiency measures or activities save energy, and savings persistence is the change in savings throughout the functional life of a given efficiency measure or activity. Savings lifetimes are essential for assessing the lifecycle benefits and cost effectiveness of efficiency activities and for forecasting loads in resource planning. The brief also provides estimates of savings lifetimes derived from a national collection of costs and savings for electric efficiency programs and portfolios.

  13. A Simplified Tool for Predicting the Thermal Behavior and the Energy Saving Potential of Ventilated Windows

    DEFF Research Database (Denmark)

    Zhang, Chen; Heiselberg, Per Kvols; Larsen, Olena Kalyanova

    2016-01-01

    windows in the early design stage. The simplified tool is developed to treat different ventilation modes: pre-heating, self-cooling and by–pass, and an operational strategy is established to determine the most energy efficient mode in each time step. Cavity air temperature and energy demand are calculated......Currently, the studies of ventilated windows mainly rely on complex fluid and thermal simulation software, which require extensive information, data and are very time consuming. The aim of this paper is to develop a simplified tool to assess the thermal behavior and energy performance of ventilated...... based on hourly weather data. The accuracy of the simplified tool is validated by full-scale experiments and numerical simulation. In addition, a case study on a single family house with ventilated windows in the Danish climate is present. The results indicate that ventilated windows have apparent...

  14. Energy Savings Through Thermally Efficient Crucible Technology: Fundamentals, Process Modeling, and Applications

    Science.gov (United States)

    Shi, Wenwu; Pinto, Brian

    2017-11-01

    Melting and holding molten metals within crucibles accounts for a large portion of total energy demand in the resource-intensive nonferrous foundry industry. Multivariate mathematical modeling aided by detailed material characterization and advancements in crucible technologies can make a significant impact in the areas of cost-efficiency and carbon footprint reduction. Key thermal properties such as conductivity and specific heat capacity were studied to understand their influence on crucible furnace energy consumption during melting and holding processes. The effects of conductivity on thermal stresses and longevity of crucibles were also evaluated. With this information, accurate theoretical models using finite element analysis were developed to study total energy consumption and melting time. By applying these findings to recent crucible developments, considerable improvements in field performance were reported and documented as case studies in applications such as aluminum melting and holding.

  15. An automatic energy-saving and thermal monitoring/controlling system for a pond

    Directory of Open Access Journals (Sweden)

    Cheng Ching-Chien

    2017-01-01

    Full Text Available Because of low temperatures and oxygen in cold water, fish will die when cold currents arrive. This will cause tremendous loss of money. In order reduce the cooling of the pond, an automatic thermal detecting and cold-roofing system using a wind-proofing device, heaters, and thermal detectors is proposed. To reduce heat loss due to thermal convection above the pond surface, a motor-driven wind-proofing device automatically controlled by a PLC controller is adopted. Here, the wind-proofing device, thermal detectors, and heating system are connected to the PLC controller. The PLC will also be connected to the PC interface. The temperature thresholds used to trigger the heater and the wind proofing device can be set at the PC interface. Two options for manipulating the heating and the automatic heating can be selected. The related wind-proofing area and the number of heaters will be determined according to the current temperature. Moreover, the PLC can be wirelessly connected to the server PC in the control room. The pond keeper can monitor everything online and control the pond water's temperature. With this, the problem of fish dying in a cold wave can be solved. Consequently, to reduce the electrical exhaust when heating up the pond water, green energy, solar energy and wind energy, is used.

  16. Savings in Cooling Energy with a Thermal Management System for LED Lighting in Office Buildings

    Directory of Open Access Journals (Sweden)

    Byung-Lip Ahn

    2015-06-01

    Full Text Available Light-emitting diode (LED lighting should be considered for lighting efficiency enhancement, however, waste heat from light-emitting diode (LED lighting increases the internal cooling load during the summer season. In order to solve this problem we propose a thermal management system for light-emitting diode (LED lighting with a heat exchanger module integrated with the building’s heating, ventilation, and air conditioning (HVAC system to move the lighting’s waste heat outdoors. An experiment was carried out to investigate the thermal effects in a test chamber and the heat exchange rate between the heat sink and the duct air. The heat generated by the light-emitting diode (LED lighting was calculated as 78.1% of light-emitting diode (LED input power and the heat exchange rate of the lighting heat exchange module was estimated to be between 86.5% and 98.1% according to the light-emitting diode (LED input power and the flow rate of air passing the heat sink. As a result, the average light-emitting diode (LED lighting heat contribution rate for internal heat gain was determined as 0.05; this value was used to calculate the heating and cooling energy demand of the office building through an energy simulation program. In the simulation results, the cooling energy demand was reduced by 19.2% compared with the case of conventionally installed light-emitting diode (LED lighting.

  17. Characterization of Energy Savings and Thermal Comfort Improvements Derived from Using Interior Storm Windows

    Energy Technology Data Exchange (ETDEWEB)

    Knox, Jake R.; Widder, Sarah H.

    2013-09-30

    This field study of a single historic home in Seattle, WA documents the performance of Indow Windows’s interior storm window inserts. Energy use and the temperature profile of the house were monitored before and after the installation of the window inserts and changes in the two recorded metrics were examined. Using the defined analysis approach, it was determined that the interior storm windows produced a 22% reduction of the HVAC energy bill and had an undetermined effect on the thermal comfort in the house. Although there was no measurable changes in the thermal comfort of the house, the occupant noted the house to be “warmer in the winter and cooler in the summer” and that the “temperatures are more even (throughout the house).” The interior storm windows were found to be not cost effective, largely due to the retrofits completed on its heating system. However, if the economic analysis was conducted based on the old heating system, a 72% efficient oil fired furnace, the Indow Windows proved to be economical and had a simple payback period of 9.0 years.

  18. Building automation: Photovoltaic assisted thermal comfort management system for energy saving

    Science.gov (United States)

    Reyasudin Basir Khan, M.; Jidin, Razali; Pasupuleti, Jagadeesh; Azwa Shaaya, Sharifah

    2013-06-01

    Building automation plays an important key role in the means to reduce building energy consumption and to provide comfort for building occupants. It is often that air conditioning system operating features ignored in building automation which can result in thermal discomfort among building occupants. Most automation system for building is expensive and incurs high maintenance cost. Such system also does not support electricity demand side management system such as load shifting. This paper discusses on centralized monitoring system for room temperature and photovoltaic (PV) output for feasibility study of PV assisted air conditioning system in small office buildings. The architecture of the system consists of PV modules and sensor nodes located at each room. Wireless sensor network technology (WSN) been used for data transmission. The data from temperature sensors and PV modules transmitted to the host personal computer (PC) wirelessly using Zigbee modules. Microcontroller based USB data acquisition device used to receive data from sensor nodes and displays the data on PC.

  19. Locomotive energy savings possibilities

    Directory of Open Access Journals (Sweden)

    Leonas Povilas LINGAITIS

    2009-01-01

    Full Text Available Economic indicators of electrodynamic braking have not been properly estimated. Vehicles with alternative power trains are transitional stage between development of pollution- free vehicles. According to these aspects the investigation on conventional hybrids drives and their control system is carried out in the article. The equation that allows evaluating effectiveness of regenerative braking for different variants of hybrid drive are given. Presenting different types of locomotive energy savings power systems, which are using regenerative braking energy any form of hybrid traction vehicles systems, circuit diagrams, electrical parameters curves.

  20. THE EFFECTS OF UTILIZING GEOTHERMAL ENERGY IN THERMAL POWER PLANTS ON THE PLANT PERFORMANCE AND FUEL SAVING

    Directory of Open Access Journals (Sweden)

    Ahmet DAĞDAŞ

    2006-02-01

    Full Text Available The share of electricity production from thermal power plants for Turkey is about 61 %. Since the fossil fuels are rapidly consumed, the concept of fossil fuel saving is very important for humanity. In this paper, the effects of boiler feed water preheating by means of geothermal brine on overall performance and fossil fuel savings in thermal power plants are examined. According to the performed analysis, power plant thermal efficiency could be increased of 2-4 % via geothermal preheating. In this analysis, a hypothetical thermal power plant is considered and its performance is evaluated. According to analysis, 1 million US$ in fossil fuel savings and 4.1 % increase in thermal efficiency could be achieved by the use of geothermal preheating.

  1. How to Save Money by Saving Energy.

    Science.gov (United States)

    Department of Energy, Washington, DC.

    This pamphlet presents energy conservation tips to help consumers save money. Conservation measures suggested here cover topics such as: (1) insulation; (2) space heating and cooling; (3) hot water heating; (4) cooking; (5) laundry; (6) lighting; (7) electrical appliances; (8) buying or building a home; and (9) buying, maintaining and driving a…

  2. Preparation and performance of thermal insulation energy saving coating materials for exterior wall.

    Science.gov (United States)

    Wang, Fei; Liang, Jinsheng; Tang, Qingguo; Chen, Gong; Chen, Yalei

    2014-05-01

    Nano zinc oxide with a high refractive index has good thermal reflection performance, hollow glass microspheres have good thermal reflection and insulation performance, and sepiolite nanofibers with many nanostructural pores have good thermal insulation performance. The dispensability of nano zinc oxide in coating materials was improved by optimizing surface silane coupling agent modification process, leading to the good thermal reflection performance. The thermal insulation performance was improved by hollow glass microspheres and sepiolite nanofibers. On this basis, the thermal insulation coating materials were prepared by exploring the effect of amount, complex mode, and other factors of the above three kinds of functional fillers on the thermal reflection and insulation performance of coating materials. The results showed that the surface modification effect of nano zinc oxide was the best when the silane coupling agent addition was 6%. The reflection and insulation performance of the coatings were the best when the additions of modified nano zinc oxide, hollow glass microspheres, and sepiolite nanofibers were 3%, 4%, and 4%, respectively. Compared with the control coating materials, the thermal insulation effect was improved obviously, which was evaluated by the -13.5 degrees C increase of maximum temperature difference between the upper and the lower surfaces.

  3. Energy saving synergies in national energy systems

    DEFF Research Database (Denmark)

    Thellufsen, Jakob Zinck; Lund, Henrik

    2015-01-01

    In the transition towards a 100% renewable energy system, energy savings are essential. The possibility of energy savings through conservation or efficiency increases can be identified in, for instance, the heating and electricity sectors, in industry, and in transport. Several studies point...... to various optimal levels of savings in the different sectors of the energy system. However, these studies do not investigate the idea of energy savings being system dependent. This paper argues that such system dependency is critical to understand, as it does not make sense to analyse an energy saving...... without taking into account the actual benefit of the saving in relation to the energy system. The study therefore identifies a need to understand how saving methods may interact with each other and the system in which they are conducted. By using energy system analysis to do hourly simulation...

  4. Energy saving statutes and regulations

    Energy Technology Data Exchange (ETDEWEB)

    Rado, L.

    1981-11-01

    The West German Federal government and the state governments are endeavouring to introduce energy saving measures with the aid of statutes, regulations, and ordinances. In his introductory remarks, the author briefly refers to the various activities since 1974 and on the basis of a 1976 report subjects the present status of statutes and ordinances on energy saving measures to a critical analysis. Special emphasis is placed on the interest of the gas supply industry.

  5. Potential energy savings

    DEFF Research Database (Denmark)

    Schultz, Jørgen Munthe

    1996-01-01

    The background for the simulations of annual energy consumption and indoor temperature level is described.......The background for the simulations of annual energy consumption and indoor temperature level is described....

  6. Behaviour : Seeing heat saves energy

    NARCIS (Netherlands)

    Steg, Linda

    2016-01-01

    Household energy conservation can help to significantly lower energy consumption. Visual cues provided by thermal imaging of heat loss in buildings are now shown to increase energy conserving behaviours and implementations among homeowners more effectively than just performing carbon footprint

  7. Energy Savings in a Market Economy

    DEFF Research Database (Denmark)

    Nørgaard, Jørgen

    1998-01-01

    The paper outlines the concept of energy savings as opposed to energy efficency. Afterwards are described briefly the up and down role of energy savings in recent Danish energy policy. It discusses the failure of leaving electricity savings and Integrated Resource Planning to the electricity...... and discussed. This finally leads to the difficulties in combining a more free market for energy in EU with a strong efforts to save energy. Ideas for electricity and heat saving policies are suggested....

  8. Energy savings in Polish buildings

    Energy Technology Data Exchange (ETDEWEB)

    Markel, L.C.; Gula, A.; Reeves, G.

    1995-12-31

    A demonstration of low-cost insulation and weatherization techniques was a part of phase 1 of the Krakow Clean Fossil Fuels and Energy Efficient Project. The objectives were to identify a cost-effective set of measures to reduce energy used for space heating, determine how much energy could be saved, and foster widespread implementation of those measures. The demonstration project focused on 4 11-story buildings in a Krakow housing cooperative. Energy savings of over 20% were obtained. Most important, the procedures and materials implemented in the demonstration project have been adapted to Polish conditions and applied to other housing cooperatives, schools, and hospitals. Additional projects are being planned, in Krakow and other cities, under the direction of FEWE-Krakow, the Polish Energie Cities Network, and Biuro Rozwoju Krakowa.

  9. Saving Green on Energy Costs

    Science.gov (United States)

    Tacke, Diane L.

    2006-01-01

    In recent years, colleges and universities have begun efforts to reduce their energy costs, an initiative that can not only save an institution money, but also strengthen relationships across campus. Board leadership has been central to this endeavor in setting goals, prioritizing projects, and financing those projects. Using her experiences with…

  10. Models of Energy Saving Systems

    DEFF Research Database (Denmark)

    Nørgård, Jørgen Stig

    1999-01-01

    The paper first describes the concepts and methods around energy saving, such as energy chain, energy services, end-use technologies, secondary energy, etc. Next are discussed the problems of defining and adding energy services and hence end-use energy efficiency or intensity. A section is devoted...... to what is termed lifestyle efficiency, including the cultural values and the ability of the economy to provide the services wanted. As explained, integrated resource planning with its optimizing the whole energy chain cannot be combined with sub-optimizing part of it, for instance the supply technology...... only. The need for including also the economic policy in the energy planning is illustrated with what is termed the efficiency pittfall. This points towards difficulties in imaging an integrated resource planning combined with a liberalized market. The three variable parameters, population, energy...

  11. Indoor Solar Thermal Energy Saving Time with Phase Change Material in a Horizontal Shell and Finned-Tube Heat Exchanger

    Directory of Open Access Journals (Sweden)

    S. Paria

    2015-01-01

    Full Text Available An experimental as well as numerical investigation was conducted on the melting/solidification processes of a stationary phase change material (PCM in a shell around a finned-tube heat exchanger system. The PCM was stored in the horizontal annular space between a shell and finned-tube where distilled water was employed as the heat transfer fluid (HTF. The focus of this study was on the behavior of PCM for storage (charging or melting and removal (discharging or solidification, as well as the effect of flow rate on the charged and discharged solar thermal energy. The impact of the Reynolds number was determined and the results were compared with each other to reveal the changes in amount of stored thermal energy with the variation of heat transfer fluid flow rates. The results showed that, by increasing the Reynolds number from 1000 to 2000, the total melting time decreases by 58%. The process of solidification also will speed up with increasing Reynolds number in the discharging process. The results also indicated that the fluctuation of gradient temperature decreased and became smooth with increasing Reynolds number. As a result, by increasing the Reynolds number in the charging process, the theoretical efficiency rises.

  12. Indoor solar thermal energy saving time with phase change material in a horizontal shell and finned-tube heat exchanger.

    Science.gov (United States)

    Paria, S; Sarhan, A A D; Goodarzi, M S; Baradaran, S; Rahmanian, B; Yarmand, H; Alavi, M A; Kazi, S N; Metselaar, H S C

    2015-01-01

    An experimental as well as numerical investigation was conducted on the melting/solidification processes of a stationary phase change material (PCM) in a shell around a finned-tube heat exchanger system. The PCM was stored in the horizontal annular space between a shell and finned-tube where distilled water was employed as the heat transfer fluid (HTF). The focus of this study was on the behavior of PCM for storage (charging or melting) and removal (discharging or solidification), as well as the effect of flow rate on the charged and discharged solar thermal energy. The impact of the Reynolds number was determined and the results were compared with each other to reveal the changes in amount of stored thermal energy with the variation of heat transfer fluid flow rates. The results showed that, by increasing the Reynolds number from 1000 to 2000, the total melting time decreases by 58%. The process of solidification also will speed up with increasing Reynolds number in the discharging process. The results also indicated that the fluctuation of gradient temperature decreased and became smooth with increasing Reynolds number. As a result, by increasing the Reynolds number in the charging process, the theoretical efficiency rises.

  13. European Union Energy Saving Policy

    Directory of Open Access Journals (Sweden)

    Nikolay Y. Kaveshnikov

    2014-01-01

    Full Text Available This article analyses methods of energy efficiency stimulation in the European Union. The author investigates basic areas of the EU activity; in particular, the author estimates results of implementation of the Energy Star program, new provisions of labeling of energy-using products, measures to increase energy efficiency in buildings. The paper also analyzes the provisions of the Directive 2012/27 that is the first EU document, providing for a comprehensive approach to energy saving at all stages: production, transformation and consumption. Today EU policy includes: 7 a general political and regulatory framework laid down by the European action plan on energy efficiency and Directive 2012/27; 2 national action plans on energy efficiency, which should be in line with indicative targets set at the EU level; 3 special EU documents in key areas of energy efficiency (buildings, energy-consuming equipment etc.; 4 accompanying instruments, such as target funding, information dissemination, support of specialized networks. The paper gives a comprehensive analysis of the key methods of implementation of EU policy in the area of energy saving. The author concludes that EU operates within the framework of the open method of coordination. The system of mandatory/voluntary technical standards has allowed to achieve significant success, but indicative planning and monitoring of national actions are not completely effective. In the long term EU policy in the area of energy efficiency is restrained by member states unwillingness to delegate to the European Union a more detailed powers in this field and to give the EU bodies facilities to execute more strict control. In the short term - in conditions of economic crisis, the EU countries are not ready to invest significant budget funds in projects with long payback period.

  14. Energy supply and energy saving in Ukraine

    Directory of Open Access Journals (Sweden)

    V.M. Ilchenko

    2015-09-01

    Full Text Available The article examines the main problems and solutions of energy saving and energy supply in Ukraine. Low energy efficiency has become one of the main factors of the crisis in the Ukrainian economy. The most relevant scientific and methodical approaches to assessment of the level of energy consumption and saving are indicated. The comparative analysis of annual energy use has been made. A potential to solve energy supply problems is strongly correlated with the ability to ensure the innovative development of economy for efficient and economical use of existing and imported energy resources. The ways for reducing of energy resource consumption have been suggested. Creation of technological conditions for the use of alternative energy sources is considered to be rational also. The development of renewable sources of energy (alternative and renewable energy sources will provide a significant effect in reducing the use of traditional energy sources, harmful emissions and greenhouse gas. Under these conditions, increasing of energy efficiency of economy and its competitiveness can be real. Improvement of environmental and social conditions of citizens of the country will mark a positive step towards the EU, and also will cancel some problems of the future generation.

  15. Investigation of thin film energy-saving coatings

    Directory of Open Access Journals (Sweden)

    Bukhmirov Vyacheslav

    2017-01-01

    Full Text Available The report presents the results of an experimental study of the thermophysical properties and energy efficiency of thin-film energy-saving coatings consisting of hollow microspheres and a binder material from styrene-acrylic dispersion. The value of the thermal conductivity coefficient of the energy-saving paint is estimated depending on its composition and temperature, and the thermal diffusivity coefficient is determined. Experimental results of energy efficiency of using thin-film coatings for insulation of facades of buildings and as thermal insulation for pipelines with a hot coolant are presented.

  16. The technical-economic potential of thermal energy saving in hospitals; El potencial tecnico-economico de ahorro de energia termica en hospitales

    Energy Technology Data Exchange (ETDEWEB)

    Herrera, A. [Universidad Nacional Autonoma de Mexico (Mexico); Islas, J [Universidad Nacional Autonoma de Mexico, Mexico, D.F. (Mexico); Arriola, A. [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2001-07-01

    The hospitals are important consumers of energy. At the General Hospital of Zone (HGZ) N of the IMSS in Aguscalientes (HGZ N . IMSS Ags.), the diesel oil is the main fuel that is used to satisfy the requirements of thermal energy of the hospital. According to the data collected by this author, this fuel represented in 2001, 75% of its total energy consumption and the 67.9% of its total costs in energy that ascended to $396.131 (December 2001 Dollars) Since this last amount represents an important percentage of the total expenses of the hospital (29.367 million dollars) it is important to determine the technical-economic possibilities of thermal energy saving of the hospital. The HGZ N 1 IMSS Ags. is located in a ampler conglomerate where the IMSS units are located, such as, the regional laundry, the sport unit, the center of social security, the familiar medicine unit N 1 and the hospital. Nevertheless departing from the installation of the electrical systems and the provision of steam and hot water to the hospital, the electrical and thermal fluids of all this facilities are distributed. Due to this situation, in this work we will refer to the global consumption of the IMSS of Aguascalientes development where the hospital is the main consumer of thermal energy. In the present work we will calculate the technical-economic potential of thermal energy saving in the development of the IMSS through the thermodynamic technique of folding point or pinch technique. [Spanish] Los hospitales son importantes consumidores de energia. En el Hospital General de Zona N del IMSS en Aguscalientes (HGZ N - IMSS Ags.), el diesel es el principal combustible que se usa para satisfacer los requerimientos de energia termica del hospital. Segun los datos obtenidos por el autor anterior, este combustible represento en 2001 el 75% de su consumo total energetico y el 67.9% de sus costos totales en energeticos que ascendieron a $396,131 (dolares de diciembre de 2001). Dado que esta ultima

  17. Energy Savings Measure Packages. Existing Homes

    Energy Technology Data Exchange (ETDEWEB)

    Casey, Sean [National Renewable Energy Lab. (NREL), Golden, CO (United States); Booten, Chuck [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2011-11-01

    This document presents the most cost effective Energy Savings Measure Packages (ESMP) for existing mixed-fuel and all electric homes to achieve 15% and 30% savings for each BetterBuildings grantee location across the United States. These packages are optimized for minimum cost to homeowners for source energy savings given the local climate and prevalent building characteristics (i.e. foundation types). Maximum cost savings are typically found between 30% and 50% energy savings over the reference home; this typically amounts to $300 - $700/year.

  18. Modern drying technology. Vol. 4. Energy savings

    Energy Technology Data Exchange (ETDEWEB)

    Tsotsas, Evangelos [Magdeburg Univ. (Germany). Thermal Process Engineergin; Mujumdar, Arun S. (eds.) [National Univ. of Singapore (Singapore). Dept. of Mechanical Engineering

    2012-07-01

    This five-volume series provides a comprehensive overview of all important aspects of modern drying technology, concentrating on the transfer of cutting-edge research results to industrial use. Volume 4 deals with energy savings and the optimization of various drying processes in a variety of areas. Reduction of energy usage in drying is becoming an important consideration in industry in order to conserve the finite fossil fuel resources, reduce carbon footprint and combat climate change. This volume focuses on the following areas: Energy analysis of dryers, solid-liquid separation processes and techniques, osmotic dehydration, heat pump assisted drying technology, zeolite usage, solar drying, drying and heat treatment for solid wood and other biomass sources, and sludge thermal processing. (orig.)

  19. COMPUTER MODELLING OF ENERGY SAVING EFFECTS

    Directory of Open Access Journals (Sweden)

    Marian JANCZAREK

    2016-09-01

    Full Text Available The paper presents the analysis of the dynamics of the heat transfer through the outer wall of the thermal technical spaces, taking into account the impact of the sinusoidal nature of the changes in atmospheric temperature. These temporal variations of the input on the outer surface of the chamber divider result at the output of the sinusoidal change on the inner wall of the room, but suitably suppressed and shifted in phase. Properly selected phase shift is clearly important for saving energy used for the operation associated with the maintenance of a specific regime of heat inside the thermal technical chamber support. Laboratory tests of the model and the actual object allowed for optimal design of the chamber due to the structure of the partition as well as due to the orientation of the geographical location of the chamber.

  20. Study on thermal comfort, air quality and energy savings using bioenergy via gasification/combustion for space heating of a broiler house

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Jadir Nogueira da; Zanatta, Fabio Luiz; Tinoco, Ilda de Fatima F.; Martin, Samuel [Universidade Federal de Vicosa (DEA/UFV), MG (Brazil). Dept. de Engenharia Agricola], E-mail: jadir@ufv.br; Scholz, Volkhard [Leibniz Institut fuer Agrartechnik- ATB, Potsdam (Germany)

    2008-07-01

    The annual production of chicken meat is increasing throughout the world and Brazil is the world leader regarding exportation, a prediction indicates about 2.7 millions tons to be exported in 2007. A key to this performance is the low production costs, however, the costs of space heating necessary during the first 3 weeks of the chick's life and is increasing significantly. For this reason, it is always necessary to search for most efficient systems for this purpose. In addition to that, the use of bioenergy is gaining importance since it is renewable and ecologically correct. A close coupled gasification/combustion system, using eucalyptus firewood (Eucalyptus grandis and/or Eucalyptus urophylla) as fuel, was tested with the objective of providing thermal comfort for the birds during their first 3 weeks after birth. An experiment was set up for this purpose in an industrial scale production facility. The results indicated that the gasification/combustion system is viable for space heating for chicks, does not alters significantly the air quality, regarding CO, CO{sub 2} and NH{sub 3} concentration inside poultry house, provides the best thermal comfort as compared to indirect fired furnaces and accounts for a 35% energy savings, leading to lower production costs. (author)

  1. Energy-saving motor; Energiesparmotor

    Energy Technology Data Exchange (ETDEWEB)

    Lindegger, M.

    2002-07-01

    This report for the Swiss Federal Office of Energy (SFOE) describes the development and testing of an advanced electrical motor using a permanent-magnet rotor. The aims of the project - to study the technical feasibility and market potential of the Eco-Motor - are discussed and the three phases of the project described. These include the calculation and realisation of a 250-watt prototype operating at 230 V, the measurement of the motor's characteristics as well as those of a comparable asynchronous motor on the test bed at the University of Applied Science in Lucerne, Switzerland, and a market study to establish if the Eco-Motor and its controller can compete against normal asynchronous motors. Also, the results of an analysis of the energy-savings potential is made, should such Eco-Motors be used. Detailed results of the three phases of the project are presented and the prospects of producing such motors in Switzerland for home use as well as for export are examined.

  2. DETERMINING ENERGY SAVINGS IN BUILDINGS USING THE REDUCING COSTS METHOD

    OpenAIRE

    STAN IVAN F.E.; MIRCEA I

    2015-01-01

    The paper is structured in four parts. The first part presents the importance of thermal insulation for buildings energy economy and some insulation properties. In the second part of the paper it is described the reducing cost method to determine the energy savings. The third part of the paper includes an analysis and a comparison for an exterior wall provided with different thicknesses of insulation layer in order to determine the average savings cost. The last par...

  3. Energy Saver: Tips on Saving Money & Energy at Home

    Energy Technology Data Exchange (ETDEWEB)

    None

    2017-09-01

    Provides consumers with home energy and money savings tips such as insulation, weatherization, heating, cooling, water heating, energy efficient windows, landscaping, lighting, and energy efficient appliances.

  4. Energy Savers: Tips on Saving Money & Energy at Home

    Energy Technology Data Exchange (ETDEWEB)

    None

    2011-12-01

    Provides consumers with home energy and money savings tips such as insulation, weatherization, heating, cooling, water heating, energy efficient windows, landscaping, lighting, and energy efficient appliances.

  5. Energy Savers Tips on Saving Energy& Money at Home

    Energy Technology Data Exchange (ETDEWEB)

    2003-06-01

    Provides consumers with home energy and money savings tips such as insulation, weatherization, heating, cooling, water heating, energy efficient windows, landscaping, lighting, and energy efficient appliances

  6. Energy Savers: Tips on Saving Money & Energy at Home

    Energy Technology Data Exchange (ETDEWEB)

    None

    2014-05-01

    Provides consumers with home energy and money savings tips such as insulation, weatherization, heating, cooling, water heating, energy efficient windows, landscaping, lighting, and energy efficient appliances.

  7. Housing-related lifestyle and energy saving

    DEFF Research Database (Denmark)

    Thøgersen, John

    2017-01-01

    A new instrument for measuring housing-related lifestyle (HRL) is introduced and employed for identifying national and cross-national HRL segments in 10 European countries (N = 3190). The identified HRL segments are profiled and the practical importance of HRL for everyday energy-saving efforts...... in the home and for the energy-consumer’s openness to new energy saving opportunities (i.e., energy saving innovativeness) is investigated. The HRL instrument’s 71 items load on 16 dimensions within five lifestyle elements. Multi-group confirmatory factor analysis reveals that the instrument possesses metric...... of relevant background characteristics. A multivariate GLM analysis reveals that when differences in housing-related lifestyles are controlled, neither country of residence nor the interaction between lifestyle and country of residence influence energy saving innovativeness or everyday energy-saving efforts...

  8. Risk transfer via energy savings insurance

    Energy Technology Data Exchange (ETDEWEB)

    Mills, Evan

    2001-10-01

    Among the key barriers to investment in energy efficiency improvements are uncertainties about attaining projected energy savings and apprehension about potential disputes over these savings. The fields of energy management and risk management are thus intertwined. While many technical methods have emerged to manage performance risks (e.g. building commissioning), financial risk transfer techniques are less developed in the energy management arena than in other more mature segments of the economy. Energy Savings Insurance (ESI) - formal insurance of predicted energy savings - is one method of transferring financial risks away from the facility owner or energy services contractor. ESI offers a number of significant advantages over other forms of financial risk transfer, e.g. savings guarantees or performance bonds. ESI providers manage risk via pre-construction design review as well as post-construction commissioning and measurement and verification of savings. We found that the two mos t common criticisms of ESI - excessive pricing and onerous exclusions - are not born out in practice. In fact, if properly applied, ESI can potentially reduce the net cost of energy savings projects by reducing the interest rates charged by lenders, and by increasing the level of savings through quality control. Debt service can also be ensured by matching loan payments to projected energy savings while designing the insurance mechanism so that payments are made by the insurer in the event of a savings shortfall. We estimate the U.S. ESI market potential of $875 million/year in premium income. From an energy-policy perspective, ESI offers a number of potential benefits: ESI transfers performance risk from the balance sheet of the entity implementing the energy savings project, thereby freeing up capital otherwise needed to ''self-insure'' the savings. ESI reduces barriers to market entry of smaller energy services firms who do not have sufficiently strong balance

  9. User behaviour impact on energy savings potential

    DEFF Research Database (Denmark)

    Rose, Jørgen

    2014-01-01

    When buildings are to undergo energy upgrading in Denmark, the national compliance checker, Be10, is often used to calculate expected energy savings for different energy-saving measures. The Be10 calculation is, however, very dependent on a variety of standard assumptions concerning the building ......, 3) Domestic hot water consumption and 4) Air change rate. Based on the analysis, a methodology is established that can be used to make more realistic and accurate predictions of expected energy savings associated with energy upgrading taking into account user behaviour....

  10. Energy efficiency: Building labels lead to savings

    Science.gov (United States)

    Walls, Margaret

    2017-03-01

    Various programmes have been introduced to increase energy efficiency in buildings. A study of commercial buildings in Los Angeles, USA, now finds that voluntary certification programmes have been effective at lowering energy use, bringing savings of up to 30%.

  11. User behaviour impact on energy savings potential

    DEFF Research Database (Denmark)

    Rose, Jørgen

    2014-01-01

    and the residents' behaviour and if these defaults do not reflect actual circumstances, it can result in non-realisation of expected energy savings. Furthermore, a risk also exists that residents' behaviour change after the energy upgrading, e.g. to obtain improved comfort than what was possible before...... the upgrading and this could lead to further discrepancies between the calculated and the actual energy savings. This paper presents an analysis on how residents’ behaviour and the use of standard assumptions may influence expected energy savings. The analysis is performed on two typical singlefamily houses......, 3) Domestic hot water consumption and 4) Air change rate. Based on the analysis, a methodology is established that can be used to make more realistic and accurate predictions of expected energy savings associated with energy upgrading taking into account user behaviour....

  12. Energy savings in Danish residential building stock

    DEFF Research Database (Denmark)

    Tommerup, Henrik M.; Svendsen, Svend

    2006-01-01

    A large potential for energy savings exists in the Danish residential building stock due to the fact that 75% of the buildings were constructed before 1979 when the first important demands for energy performance of building were introduced. It is also a fact that many buildings in Denmark face...... comprehensive renovations in the coming years and in connection with this renovation process energy saving measures can be implemented relatively inexpensive and cost effective. This opportunity should be used to insure the buildings in the future as far as energy consumption is concerned. This paper gives...... buildings representing the residential building stock and based on these calculations an assessment of the energy-saving potential is performed. A profitable savings potential of energy used for space heating of about 80% is identified over 45 years (until 2050) within the residential building stock...

  13. Seasonal thermal energy storage

    Energy Technology Data Exchange (ETDEWEB)

    Allen, R.D.; Kannberg, L.D.; Raymond, J.R.

    1984-05-01

    This report describes the following: (1) the US Department of Energy Seasonal Thermal Energy Storage Program, (2) aquifer thermal energy storage technology, (3) alternative STES technology, (4) foreign studies in seasonal thermal energy storage, and (5) economic assessment.

  14. Values and Technologies in Energy Savings

    DEFF Research Database (Denmark)

    Nørgård, Jørgen Stig

    2000-01-01

    The chapter is based on the assumption, that technology improvement is not sufficient to achieve a sustainable world community. Changes in people´s values are necessary. A simple model suggest how values, together with basic needs and with the environmental and societal frames, determine people......´s behavioural pattern and lifestyles. Deliberate changes in social values are illustrated by a historical example. From the side of technology the basic principles in the economy of energy savings are briefly described. The marginally profitable energy savings provides an economic saving. The application...... of this saving can cause what is called the rebound effect, which reduces the savings obtained from the technology. Ways to avoid this effect are suggested, and they require value changes, primarly around frugality, consumption, and hard-working. There are indications that some of the necessary changes are well...

  15. Short Communication: Electrical energy saving through lamps ...

    African Journals Online (AJOL)

    Modern Buildings of all types relies heavily on the use of electrical energy. This energy has to be properly utilized in order to avoid many problems both to the electric utilities supply companies and also to the consumer. This paper presents energy saving through replacement process of conventional electric lamps known ...

  16. Superconductivity by kinetic energy saving?

    NARCIS (Netherlands)

    Van der Marel, D; Molegraaf, HJA; Presura, C; Santoso, [No Value; Hewson, AC; Zlatic,

    2003-01-01

    A brief introduction is given in the generic microscopic framework of superconductivity. The consequences for the temperature dependence of the kinetic energy, and the correlation energy are discussed for two cases: The BCS scenario and the non-Fermi liquid scenario. A quantitative comparison is

  17. DETERMINING ENERGY SAVINGS IN BUILDINGS USING THE REDUCING COSTS METHOD

    Directory of Open Access Journals (Sweden)

    STAN IVAN F.E.

    2015-03-01

    Full Text Available The paper is structured in four parts. The first part presents the importance of thermal insulation for buildings energy economy and some insulation properties. In the second part of the paper it is described the reducing cost method to determine the energy savings. The third part of the paper includes an analysis and a comparison for an exterior wall provided with different thicknesses of insulation layer in order to determine the average savings cost. The last part presents conclusions and discussion.

  18. Energy Saving and Efficient Energy Use By Power Electronic Systems

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Wang, Huai; Davari, Pooya

    2017-01-01

    In the development of the modern society, one of the key factors is to save energy in order to become more independent of other energy resources. Two important approaches can be taken—one is to change behavior and thereby save energy—the second one is to develop new technology which is able to save...... energy in different applications. This chapter will give an overview of challenges and possibilities in terms of energy saving and also energy efficient use. This includes a discussion on high efficiency power electronics devices and the systems they are used for energy loss reduction. The key enabling...... technologies are power electronics, Information and Communication Technology (ICT) as well as systems to carry the electrical energy through power transmission, conversion and distribution. A couple of examples will be given to demonstrate the energy saving possibilities by power electronics systems...

  19. Energy Savings from Industrial Water Reductions

    Energy Technology Data Exchange (ETDEWEB)

    Rao, Prakash; McKane, Aimee; de Fontaine, Andre

    2015-08-03

    Although it is widely recognized that reducing freshwater consumption is of critical importance, generating interest in industrial water reduction programs can be hindered for a variety of reasons. These include the low cost of water, greater focus on water use in other sectors such as the agriculture and residential sectors, high levels of unbilled and/or unregulated self-supplied water use in industry, and lack of water metering and tracking capabilities at industrial facilities. However, there are many additional components to the resource savings associated with reducing site water use beyond the water savings alone, such as reductions in energy consumption, greenhouse gas emissions, treatment chemicals, and impact on the local watershed. Understanding and quantifying these additional resource savings can expand the community of businesses, NGOs, government agencies, and researchers with a vested interest in water reduction. This paper will develop a methodology for evaluating the embedded energy consumption associated with water use at an industrial facility. The methodology developed will use available data and references to evaluate the energy consumption associated with water supply and wastewater treatment outside of a facility’s fence line for various water sources. It will also include a framework for evaluating the energy consumption associated with water use within a facility’s fence line. The methodology will develop a more complete picture of the total resource savings associated with water reduction efforts and allow industrial water reduction programs to assess the energy and CO2 savings associated with their efforts.

  20. Saving energy: bringing down Europe's enery prices

    NARCIS (Netherlands)

    Molenbroek, E.; Blok, K.

    2012-01-01

    In June 2011 the European Commission proposed a new Directive on Energy Efficiency. Its purpose is to put forward a framework to deliver the EU’s target of reducing its energy consumption by 20% by 2020. Currently, the EU is only on track to achieve half of those savings. Apart from the

  1. Daylight metrics and energy savings

    Energy Technology Data Exchange (ETDEWEB)

    Mardaljevic, John; Heschong, Lisa; Lee, Eleanor

    2009-12-31

    The drive towards sustainable, low-energy buildings has increased the need for simple, yet accurate methods to evaluate whether a daylit building meets minimum standards for energy and human comfort performance. Current metrics do not account for the temporal and spatial aspects of daylight, nor of occupants comfort or interventions. This paper reviews the historical basis of current compliance methods for achieving daylit buildings, proposes a technical basis for development of better metrics, and provides two case study examples to stimulate dialogue on how metrics can be applied in a practical, real-world context.

  2. Electric energy savings from new technologies

    Energy Technology Data Exchange (ETDEWEB)

    Moe, R.J.; Harrer, B.J.; Kellogg, M.A.; Lyke, A.J.; Imhoff, K.L.; Fisher, Z.J.

    1986-01-01

    Purpose of the report is to provide information about the electricity-saving potential of new technologies to OCEP that it can use in developing alternative long-term projections of US electricity consumption. Low-, base-, and high-case scenarios of the electricity savings for ten technologies were prepared. The total projected annual savings for the year 2000 for all ten technologies were 137 billion kilowatt hours (BkWh), 279 BkWh, and 470 BkWh, respectively, for the three cases. The magnitude of these savings projections can be gauged by comparing them to the Department's reference case projection for the 1985 National Energy Policy Plan. In the Department's reference case, total consumption in 2000 is projected to be 3319 BkWh. Thus, the savings projected here represent between 4% and 14% of total consumption projected for 2000. Because approximately 75% of the base-case estimate of savings are already incorporated into the reference forecast, reducing projected electricity consumption from what it otherwise would have been, the savings estimated here should not be directly subtracted from the reference forecast.

  3. Saving Energy at Data Centers

    Energy Technology Data Exchange (ETDEWEB)

    None

    2007-10-12

    Data centers provide mission-critical computing functions essential to the daily operation of top U.S. economic, scientific, and technological organizations. These data centers consume large amounts of energy to run and maintain their computer systems, servers, and associated high-performance components.

  4. Energy savings and comfort changes in buildings

    Energy Technology Data Exchange (ETDEWEB)

    Krighaar, M. [COWI (Denmark); Ivanauskas, A. [Klaipedos Energija SPAB (Lithuania)

    2000-07-01

    This article presents the results from a demonstration project on building installations in the city Klaipeda, Lithuania. The project demonstrates the energy savings and increased comfort level achieved by installation of various energy saving measures and includes a cost benefit analysis. The demonstration area consists of eight typical buildings. The outcome of the project provides a valuable basis for future decisions to be made concerning reconstruction of heating installations and enables the results and experience to be transferred to 2,500 buildings in Klaipeda and buildings in Lithuania in general. (au)

  5. Energy Savings Performance Contract Energy Sales Agreement Toolkit

    Energy Technology Data Exchange (ETDEWEB)

    None

    2017-08-14

    FEMP developed the Energy Savings Performance Contracting Energy Sales Agreement (ESPC ESA) Toolkit to provide federal agency contracting officers and other acquisition team members with information that will facilitate the timely execution of ESPC ESA projects.

  6. Reactors Save Energy, Costs for Hydrogen Production

    Science.gov (United States)

    2014-01-01

    While examining fuel-reforming technology for fuel cells onboard aircraft, Glenn Research Center partnered with Garrettsville, Ohio-based Catacel Corporation through the Glenn Alliance Technology Exchange program and a Space Act Agreement. Catacel developed a stackable structural reactor that is now employed for commercial hydrogen production and results in energy savings of about 20 percent.

  7. ENERGY SAVING MODES DEFINITION OF TRAINS HANDLING

    Directory of Open Access Journals (Sweden)

    D. M. Kyslyi

    2016-02-01

    Full Text Available Purpose. Traction calculations with the definition of energy-efficient trajectories provide search for rational energy consumption depending on the time course of the train. When selecting energy-efficient trajectory of the train and the development of regime charts conducting trains must take into account variables such as: the profile of the site, weight train, locomotive series, etc. When increasing the speed of the growth it occurs the resistance movement, which is proportional to the square of the speed, which leads to higher costs of fuel and energy resources. In contrast, the reduction of costs due to the decrease in speed leads to an increase in travel time of the train, which should be consistent with the timetable and other technical and economic parameters, depending on the speed. The article describes one way to reduce the cost of energy for traction. The aim of the article is to reduce energy consumption by identifying energy-saving control modes. It occurs with the locomotive optimization function of control actions on the running time of the train and the flow of energy in the management of the train from the end of the acceleration to go to the coasts. Methodology. The technique of choice of energy saving path of the train and power control and electric locomotives with electric transmission provides the calculation of multiple paths with variable input data and parameters of the composition of the train situation. The methodology takes into account the uniform mathematical methods of search and parametric optimization. For uniformity of motion needed to slow down the accelerating forces are balanced. Findings. On the basis of calculations of multiple advanced algorithms determine the trajectories of energy-saving trains, built multiparametric locomotive power control function, which can reduce energy consumption by 11 to 13% depending on the weight of the train and the train situation. Originality. The author obtained the energy-saving

  8. Does energy labelling on residential housing cause energy savings?

    Energy Technology Data Exchange (ETDEWEB)

    Kjaerbye, V.H.

    2009-07-01

    Danish households use more than 30% of the total amount of energy being used in Denmark. More than 80% of this energy is dedicated to space heating. The same relation is seen in many OECD countries. The corresponding energy savings potential was recently estimated at 30% of the energy used in buildings. Energy labelling is seen as an important instrument to target these potential energy savings. This paper evaluates the effects of the Danish Energy Labelling Scheme on energy consumption in existing single-family houses with propensity score matching using real metered natural gas consumption and a very wide range of register data describing the houses and households. The study did not find significant energy savings due to the Danish Energy Labelling Scheme, but more research would be needed to complement this conclusion

  9. Will Renewable Energy Save Our Planet?

    Science.gov (United States)

    Bojić, Milorad

    2010-06-01

    This paper discusses some important fundamental issues behind application of renewable energy (RE) to evaluate its impact as a climate change mitigation technology. The discussed issues are the following: definition of renewable energy, concentration of RE by weight and volume, generation of electrical energy and its power at unit area, electrical energy demand per unit area, life time approach vs. layman approach, energy return time, energy return ratio, CO2 return time, energy mix for RES production and use, geographical distribution of RES use, huge scale of energy shift from RES to non-RES, increase in energy consumption, Thermodynamic equilibrium of earth, and probable solutions for energy future of our energy and environmental crisis of today. The future solution (that would enable to human civilization further welfare, and good living, but with lower release of CO2 in atmosphere) may not be only RES. This will rather be an energy mix that may contain nuclear energy, non-nuclear renewable energy, or fossil energy with CO2 sequestration, efficient energy technologies, energy saving, and energy consumption decrease.

  10. Solar Thermal Energy Technology

    Energy Technology Data Exchange (ETDEWEB)

    Cason, D.L.; Pitsenbarger, J. [eds.

    1996-02-01

    Solar Thermal Energy Technology (PST) announces on a bimonthly basis the current worldwide research and development information that would expand the technology base required for the advancement of solar thermal systems as a significant energy resource.

  11. A New Hybrid Bathroom System Based on Energy Saving Concept

    Directory of Open Access Journals (Sweden)

    Cui Bo-wen

    2016-01-01

    Full Text Available Based on the characteristics of hot water supply in bathroom, this article proposes a new hybrid energy hot water supply system. The programmable logic controller(PLC as the master controller was adopted in this system, which could automatically detect and storage main thermal physical of the system, such as temperature, water level, solar radiation intensity, power consumption and so on. The active thermal utilization technology of solar energy, air-source heat pump technology, solar energy intensive natural ventilation technology and low temperature hot water floor radiant heating technology were organically integrated in this system, which has the advantages of energy conservation and environment protection, high automation, safe and reliable operation, etc. At the same time, it can make good use of electric power cost between on-peak and off-peak, and promote the optimal allocation of power resources and reduce the cost, which can achieve the goal of intelligent control and energy saving.

  12. Solar Energy as an Alternative to Energy Saving and Pollutant Emissions Reduction

    Directory of Open Access Journals (Sweden)

    Arina Negoițescu

    2016-10-01

    Full Text Available In the paper is analyzed thermal solar systems efficiency from the point of view of energy savings and pollutant emissions concentrations exhausted during these installations operation. For this purpose were taking into account four versions of solar panel systems combined with different types of conventional heating sources, for which were simulated the operation conditions. As a result of the simulation, there were obtained the values of energy savings and pollutant emissions during the four systems operation. By analyzing these values, the combined thermal system optimum solution was selected.

  13. Energy Savings Potential of Radiative Cooling Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, Nicholas [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wang, Weimin [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Alvine, Kyle J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Katipamula, Srinivas [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-11-30

    Pacific Northwest National Laboratory (PNNL), with funding from the U.S. Department of Energy’s (DOE’s) Building Technologies Program (BTP), conducted a study to estimate, through simulation, the potential cooling energy savings that could be achieved through novel approaches to capturing free radiative cooling in buildings, particularly photonic ‘selective emittance’ materials. This report documents the results of that study.

  14. Energy saving screw compressor technology; Energiebesparende schroefcompressortechnologie

    Energy Technology Data Exchange (ETDEWEB)

    Moeller, A. [RefComp, Lonigo (Italy); Neus, M. [Delta Technics Engineering, Breda (Netherlands)

    2011-03-15

    Smart solutions to reduce the energy consumption are continuously part of investigation in the refrigeration technology. This article subscribed the technology on which way energy can be saved at the operation of screw compressors which are used in air conditioners and refrigerating machinery. The combination of frequency control and Vi-control (intrinsic volumetric ratio) such as researched in the laboratory of RefComp is for the user attractive because the energy efficiency during part load operation is much better. Smart uses of thermodynamics, electric technology and electronic control are the basics of these applications. According to the manufacturer's information it is possible with these new generation screw compressors to save approx. 26% energy in comparison with the standard screw compressor. [Dutch] In dit artikel wordt de technologie omschreven waarmee veel energie bespaard kan worden bij schroefcompressoren die worden gebruikt in airconditioningsystemen en koel- en vriesinstallaties. De combinatie van frequentieregeling en Vi- regeling (Vi is de intrinsieke volumetrische verhouding) zoals onderzocht in het laboratorium van RefComp biedt de gebruiker veel voordelen doordat de energie-efficintie van de compressor tijdens deellast enorm wordt verbeterd. Slim gebruik van thermodynamika, elektrotechniek en elektronica vormen de basis van deze toepassing. Volgens de fabrikant kan met deze nieuwe generatie schroefcompressoren circa 26 procent op het energiegebruik tijdens deellast worden bespaard in vergelijking met de standaard serie schroefcompressoren.

  15. Energy saving and energy efficiency concepts for policy making

    NARCIS (Netherlands)

    Oikonomou, V.; Becchis, F.; Steg, L.; Russolillo, D.

    2009-01-01

    Departing from the concept of rational use of energy, the paper outlines the microeconomics of end-use energy saving as a result of frugality or efficiency measures. Frugality refers to the behaviour that is aimed at energy conservation, and with efficiency we refer to the technical ratio between

  16. Incorporating Non-energy Benefits into Energy Savings Performance Contracts

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, Peter; Goldman, Charles; Gilligan, Donald; Singer, Terry

    2012-06-01

    This paper evaluates the issue of non-energy benefits within the context of the U.S. energy services company (ESCO) industry?a growing industry comprised of companies that provide energy savings and other benefits to customers through the use of performance-based contracting. Recent analysis has found that ESCO projects in the public/institutional sector, especially at K-12 schools, are using performance-based contracting, at the behest of the customers, to partially -- but not fully -- offset substantial accumulated deferred maintenance needs (e.g., asbestos removal, wiring) and measures that have very long paybacks (roof replacement). This trend is affecting the traditional economic measures policymakers use to evaluate success on a benefit to cost basis. Moreover, the value of non-energy benefits which can offset some or all of the cost of the non-energy measures -- including operations and maintenance (O&M) savings, avoided capital costs, and tradable pollution emissions allowances-- are not always incorporated into a formal cost-effectiveness analysis of ESCO projects. Nonenergy benefits are clearly important to customers, but state and federal laws that govern the acceptance of these types of benefits for ESCO projects vary widely (i.e., 0-100percent of allowable savings can come from one or more non-energy categories). Clear and consistent guidance on what types of savings are recognized in Energy Savings agreements under performance contracts is necessary, particularly where customers are searching for deep energy efficiency gains in the building sector.

  17. Energy saving in the auxiliaries consumption for circulation water pumps optimizing the thermal regime; Ahorro en el consumo de auxiliares por bombas de agua de circulacion optimando el regimen termico

    Energy Technology Data Exchange (ETDEWEB)

    Orozco Martinez, Roni [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1998-12-31

    A methodology is proposed that should be followed in any thermal electric power plant to determine the load value at which a unit requires a second circulation water pump without affecting the thermal regime and avoiding an excessive auxiliaries consumption in partial loads. In applying this method the power plant would have an energy saving equivalent to the auxiliaries consumption during an hour, when the unit as operating at full load. [Espanol] Se propone una metodologia que debe seguirse en cualquier central termoelectrica para determinar el valor de la carga en la cual una unidad requiere de la segunda bomba de agua de circulacion sin afectar el regimen termico y evitadose un excesivo consumo de auxiliares en cargas parciales. Al aplicar este metodo la central tendria un ahorro de energia equivalente al consumo de auxiliares durante una hora cuando la unidad esta generando su maxima carga.

  18. Good practice in saving energy at school

    Science.gov (United States)

    Veronesi, Paola; Bonazzi, Enrico

    2014-05-01

    We teach students between 14 and 18 years old at a high school in Italy. In the first class, one of the topics we treat is related to the atmosphere. The students learn the composition of air, the importance of the natural greenhouse effect in keeping the average temperature of the planet and how human activity is increasing the level of greenhouse gases, enhancing greenhouse effect and causing global warming. It is possible to reach this knowledge using different materials and methods such as schoolbooks, articles, websites or films, individual or group work, but as students gradually become aware of the problem of climate change due to global warming, it is necessary to propose a solution that can be experienced and measured by students. This is the aim of the project "Switch off the light, to switch on the future". The project doesn't need special materials to be carried out but all the people in the community who work and "live" at school should participate in it. The project deals directly with saving electric energy, by changing the habits of the use of electricity. Saving electric energy means saving CO2 emitted to atmosphere, and consequently contributing to the reduction of greenhouse gases emission. Normally, lights in the school are switched on in the early morning and switched off at the end of lessons. Nobody is responsible to turn out the lights in classes, so students choose one or two "Light guardians" who are responsible for the light management. Simple rules for light management are written and distributed in the classes so that the action of saving energy is spread all over the school. One class participates in the daily data collection from the electricity meter, before and after the beginning of the action. At the end of the year the data are treated and presented to the community, verifying if the electric consumption has been cut down or not. This presentation is public, with students who directly introduce collected data, results and

  19. Economic aspects of energy saving in greenhouses: physical considerations

    CERN Document Server

    Danloy, L; Gay, J B; Mercier, J A; Reist, A

    1989-01-01

    An important result of experiments carried out over the past six years in a trial greenhouse at CERN (The European Organization for Nuclear Research, Geneva, Switzerland) was the development of a simple and precise method for calculating the energy requirements of a glasshouse; this is valid for any type of greenhouse and climate. An economic study is made using the above method for evaluating the financial effectiveness of various energy-saving methods: double glazing of the side walls, low emissivity glass 'Hortiplus' roofing, soil level heating and a thermal screen.

  20. A NOVEL OPTIMIZED ENERGY-SAVING EXTRACTION PROCESS ON COFFEE

    Directory of Open Access Journals (Sweden)

    Cheng-Chi Wang

    2011-01-01

    Full Text Available In this paper, Taguchi method is applied to optimize ultrasound thermal process for extracting caffeine and flavor from coffee. The use of ultrasound can abridge experiments in cost, energy loss and time; the different operating conditions for extraction experiments are executed and the results are also compared. The results show that the best design factors for caffeine are 95℃ of extraction temperature, 28 kHz of operating frequency and 30 s of extraction time. The proposed optimized extraction method is efficient and energy-saving compared with the general process for making coffee.

  1. Energy saving by means of air conditioning equipment replacement and the household application of thermal insulation; Ahorro de energia electrica por reemplazo de equipos de aire acondicionado y aplicacion de aislamiento termico en viviendas

    Energy Technology Data Exchange (ETDEWEB)

    Peralta Solorio, Jose Luis [Fideicomiso para el Ahorro de la Energia (Mexico)

    2005-07-15

    An extension study of the Financing Program for Energy Saving looked for the evaluation of the electric energy saving potential obtained by the replacement of air conditioning equipment and the application of thermal insulation in 30 houses of two Mexican cities with warmth climate. In a joint effort with Comision Federal de Electricidad the consumption files of the users were analyzed and field measurements of electric demand and of refrigeration were made. As a following step the change of the refrigeration necessities derived from the application of thermal insulation were evaluated as well as the energy efficiency improvement obtained by the substitution of the air conditioning equipment and the favorable results obtained by the implementation of both measures - thermal insulation and change of air conditioning equipment in a joint form. This way, as a conclusion, the optimum sequence of application of these measures is revealed. [Spanish] Un estudio extension del Programa de Financiamiento para el Ahorro de Energia Electrica busco evaluar el potencial de ahorro de energia electrica alcanzado por el reemplazo de equipos de aire acondicionado y la aplicacion de aislamiento termico en 30 viviendas de dos ciudades mexicanas con clima calido. En un esfuerzo conjunto con la Comision Federal de Electricidad se analizaron los historiales de consumo de los usuarios y se efectuaron las mediciones de campo de demanda electrica y de refrigeracion. Como paso siguiente se valoro el cambio en las necesidades de refrigeracion derivado de la aplicacion de aislamiento termico al igual que la mejora en eficiencia energetica obtenida por la sustitucion de aire acondicionado y se identificaron los resultados favorecedores arrojados por la implementacion de ambas medidas -aislamiento termico y cambio de equipo de aire acondicionado- en forma conjunta. De esta manera, como conclusion, se devela la mas optima secuencia de aplicacion de estas medidas.

  2. Shared Savings Financing for College and University Energy Efficiency Investments.

    Science.gov (United States)

    Business Officer, 1984

    1984-01-01

    Shared savings arrangements for campus energy efficient investments are discussed. Shared savings is a term for an agreement in which a private company offers to implement an energy efficiency program, including capital improvements, in exchange for a portion of the energy cost savings. Attention is directed to: types of shared savings…

  3. Energy saving lamps in the discussion; Energiesparlampen in der Diskussion

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-12-01

    In the contribution under consideration the following questions according to energy saving lamp are discussed: (a) Mercury from broken energy saving lamp - a health problem?; (b) Why did the Federal Environmental Agency (Dessau-Rosslau, Federal Republic of Germany) measure the mercury emissions from energy saving lamps?; (c) Which consequences does the Federal Environmental Agency draw from the investigations?.

  4. Energy saving opportunities of energy efficient air nozzles

    Science.gov (United States)

    Slootmaekers, Tim; Slaets, Peter; Bartsoen, Tom; Malfait, Lieven; Vanierschot, Maarten

    2015-12-01

    Compressed air is a common energy medium. The production of compressed air itself is not a very efficient process. Avoiding any unnecessary losses of air can lead to large reductions in electricity consumption. Since blowing applications are one of the main domains were compressed-air is used, any reduction in the mass flow needed for operation can lead to significant energy savings. In this paper the normal volumetric flow rate and generated impact force are compared between a stepped nozzle and a so called energy saving nozzle which allows extra air from the surroundings to be entrained. These two different nozzle geometries are used in industrial blowing applications. Until now there was no study available which compares the impact forces and volumetric flow rates for these types of nozzles. The flow field of the two nozzles was calculated by CFD simulations. The impact forces and volumetric flow rates are calculated out of this flow field. Each nozzle was simulated with three different input pressures. The nozzles were simulated with an input pressure of 3, 4 and 5 barg. The energy saving nozzle consumes only 1 % less volumetric flow rate then the stepped nozzle at the same inlet pressure. The replacement of a stepped nozzle with an energy saving nozzle will not immediately result in a decrease in input volumetric flow rate. The pressure at the inlet of the energy saving nozzle has to be reduced as well. After reducing the input pressure the energy saving nozzle generates the same impact force than the stepped nozzle. Hereby a decrease of 4.5 % in input volumetric flow rate was possible. The energy cost will decrease with 4.5 % as well because the normal volumetric flow rate is directly proportional to the energy cost. The replacement of a stepped nozzle with an energy saving nozzle while maintaining the same inlet pressure is only useful when the impact force from the stepped nozzle is not sufficient. The energy saving nozzle can generate 5.6 % more impact

  5. SWEEP - Save Water & Energy Education Program

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, Gregory P.; Elliott, Douglas B.; Hillman, Tim C.; Hadley, Adam; Ledbetter, Marc R.; Payson, David R.

    2001-05-03

    The objective of this study was to develop, monitor, analyze, and report on an integrated resource-conservation program highlighting efficient residential appliances and fixtures. The sites of study were 50 homes in two water-constrained communities located in Oregon. The program was designed to maximize water savings to these communities and to serve as a model for other communities seeking an integrated approach to energy and water resource efficiency. The program included the installation and in-place evaluation of energy- and water-efficient devices including the following: horizontal axis clothes washers (and the matching clothes dryers), resource-efficient dishwashers, an innovative dual flush low-flow toilet, low-flow showerheads, and faucet aerators. The significance of this activity lies in its integrated approach and unique metering evaluation of individual end-use, aggregated residential total use, and system-wide energy and water benefits.

  6. Energy saving and energy efficiency concepts for policy making

    Energy Technology Data Exchange (ETDEWEB)

    Oikonomou, V. [SOM, University of Groningen, PO Box 800, 9700 AV Groningen (Netherlands); Becchis, F. [POLIS Department, University of East Piedmont, via Duomo, 6-13100 Vercelli (Italy); Steg, L. [Faculty of Behavioural and Social Sciences, University of Groningen, P.O. Box 72 9700 AB (Netherlands); Russolillo, D. [Fondazione per l' Ambiente ' T. Fenoglio' , Via Gaudenzio Ferrari 1, I-10124 Torino (Italy)

    2009-11-15

    Departing from the concept of rational use of energy, the paper outlines the microeconomics of end-use energy saving as a result of frugality or efficiency measures. Frugality refers to the behaviour that is aimed at energy conservation, and with efficiency we refer to the technical ratio between energy input and output services that can be modified with technical improvements (e.g. technology substitution). Changing behaviour from one side and technology from the other are key issues for public energy policy. In this paper, we attempt to identify the effects of parameters that determine energy saving behaviour with the use of the microeconomic theory. The role of these parameters is crucial and can determine the outcome of energy efficiency policies; therefore policymakers should properly address them when designing policies. (author)

  7. Potential Energy Cost Savings from Increased Commercial Energy Code Compliance

    Energy Technology Data Exchange (ETDEWEB)

    Rosenberg, Michael I.; Hart, Philip R.; Athalye, Rahul A.; Zhang, Jian; Cohan, David F.

    2016-08-22

    An important question for commercial energy code compliance is: “How much energy cost savings can better compliance achieve?” This question is in sharp contrast to prior efforts that used a checklist of code requirements, each of which was graded pass or fail. Percent compliance for any given building was simply the percent of individual requirements that passed. A field investigation method is being developed that goes beyond the binary approach to determine how much energy cost savings is not realized. Prototype building simulations were used to estimate the energy cost impact of varying levels of non-compliance for newly constructed office buildings in climate zone 4C. Field data collected from actual buildings on specific conditions relative to code requirements was then applied to the simulation results to find the potential lost energy savings for a single building or for a sample of buildings. This new methodology was tested on nine office buildings in climate zone 4C. The amount of additional energy cost savings they could have achieved had they complied fully with the 2012 International Energy Conservation Code is determined. This paper will present the results of the test, lessons learned, describe follow-on research that is needed to verify that the methodology is both accurate and practical, and discuss the benefits that might accrue if the method were widely adopted.

  8. Chinese hotel general managers' perspectives on energy-saving practices

    Science.gov (United States)

    Zhu, Yidan

    As hotels' concern about sustainability and budget-control is growing steadily, energy-saving issues have become one of the important management concerns hospitality industry face. By executing proper energy-saving practices, previous scholars believed that hotel operation costs can decrease dramatically. Moreover, they believed that conducting energy-saving practices may eventually help the hotel to gain other benefits such as an improved reputation and stronger competitive advantage. The energy-saving issue also has become a critical management problem for the hotel industry in China. Previous research has not investigated energy-saving in China's hotel segment. To achieve a better understanding of the importance of energy-saving, this document attempts to present some insights into China's energy-saving practices in the tourist accommodations sector. Results of the study show the Chinese general managers' attitudes toward energy-saving issues and the differences among the diverse hotel managers who responded to the study. Study results indicate that in China, most of the hotels' energy bills decrease due to the implementation of energy-saving equipments. General managers of hotels in operation for a shorter period of time are typically responsible for making decisions about energy-saving issues; older hotels are used to choosing corporate level concerning to this issue. Larger Chinese hotels generally have official energy-saving usage training sessions for employees, but smaller Chinese hotels sometimes overlook the importance of employee training. The study also found that for the Chinese hospitality industry, energy-saving practices related to electricity are the most efficient and common way to save energy, but older hotels also should pay attention to other ways of saving energy such as water conservation or heating/cooling system.

  9. Energy conservation, energy efficiency and energy savings regulatory hypotheses - taxation, subsidies and underlying economics

    Energy Technology Data Exchange (ETDEWEB)

    Trumpy, T. [International Legal Counsel, Brussels (Belgium)

    1995-12-01

    More efficient use of energy resources can be promoted by various regulatory means, i.e., taxation, subsidies, and pricing. Various incentives can be provided by income and revenue tax breaks-deductible energy audit fees, energy saving investment credits, breaks for energy saving entrepreneurs, and energy savings accounts run through utility accounts. Value added and excise taxes can also be adjusted to reward energy saving investments and energy saving entrepreneurial activity. Incentives can be provided in the form of cash refunds, including trade-in-and-scrap programs and reimbursements or subsidies on audit costs and liability insurance. Pricing incentives include lower rates for less energy use, prepayment of deposit related to peak load use, electronically dispatched multiple tariffs, savings credits based on prior peak use, and subsidized {open_quotes}leasing{close_quotes} of more efficient appliances and lights. Credits, with an emphasis on pooling small loans, and 5-year energy savings contracts are also discussed.

  10. Thermal energy transformer

    Science.gov (United States)

    Berdahl, C. M.; Thiele, C. L. (Inventor)

    1979-01-01

    For use in combination with a heat engine, a thermal energy transformer is presented. It is comprised of a flux receiver having a first wall defining therein a radiation absorption cavity for converting solar flux to thermal energy, and a second wall defining an energy transfer wall for the heat engine. There is a heat pipe chamber interposed between the first and second walls having a working fluid disposed within the chamber and a wick lining the chamber for conducting the working fluid from the second wall to the first wall. Thermal energy is transferred from the radiation absorption cavity to the heat engine.

  11. Purging energy costs. [Energy savings in ammonia refrigeration system

    Energy Technology Data Exchange (ETDEWEB)

    Whitwell, Ian (Energy Technology Support Unit, Harwell (United Kingdom))

    1992-09-01

    Energy savings of over Pound 8,000 per year have been achieved by Exel Logistics, which has installed a five-point automatic purger to the evaporative condenser and receiver of the ammonia refrigeration system at its Glasgow service depot. The main features of the system are described in this article. (Author).

  12. Cultivation and energy 2SaveEnergy greenhouse

    NARCIS (Netherlands)

    Kempkes, F.L.K.; Janse, J.

    2016-01-01

    Energy saving in a greenhouse with insulated glass requires a significant investment. In the search for a cheaper alternative, a consortium of companies comprising VDH Plastic Greenhouses, Van der Valk Horti Systems, AGC Chemicals Europe and Boal Systems developed a Glass-Film greenhouse cover in

  13. Teelt en energie 2SaveEnergy kas

    NARCIS (Netherlands)

    Kempkes, F.L.K.; Janse, J.

    2016-01-01

    Energy savings through a greenhouse cover of insulation glass requires a large investment. In the search for a cheaper alternative by a consortium of companies consisting of VDH Plastic Greenhouses, Van der Valk Horti Systems, AGC Chemicals Europe en Boal Systems a Glass-Film-greenhouse cover,

  14. Energy Savings Potential and Research & Development Opportunities for Commercial Refrigeration

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2009-09-01

    This study documents the energy consumption of commercial refrigeration equipment (CRE) in the U.S. and evaluated the energy savings potential of various technologies and energy efficiency measures that could be applied to such equipment. The study provided an overview of CRE applications, assessed the energy-savings potential of CRE in the U.S., outline key barriers to adoption of energy-savings technologies, and recommended opportunities for advanced energy saving technology research. The study was modeled after an earlier 1996 report by Arthur D. Little, Inc., and updated key information, examined more equipment types, and outlined long-term research and development opportunities.

  15. Technical energy savings versus changes in human behaviour

    DEFF Research Database (Denmark)

    Nørgaard, Jørgen

    1996-01-01

    Energy savings seems to be the most environmentally benign element in an energy policy. The paper is a reflection on the work on saving energy both by improving technology and by adapting human daily behaviour. A simple model is suggested for the energy chain which converts the primary energy all...... the way into human satisfaction via energy services. Results of various analyses and field experiments show saving potentials for electricity of 50 - 80 per cents. Barriers for implementing these technical saving options are discussed. Also the necessity and potentials for changing behavioural or life...

  16. Aquifer Thermal Energy Storage for Seasonal Thermal Energy Balance

    Science.gov (United States)

    Rostampour, Vahab; Bloemendal, Martin; Keviczky, Tamas

    2017-04-01

    Aquifer Thermal Energy Storage (ATES) systems allow storing large quantities of thermal energy in subsurface aquifers enabling significant energy savings and greenhouse gas reductions. This is achieved by injection and extraction of water into and from saturated underground aquifers, simultaneously. An ATES system consists of two wells and operates in a seasonal mode. One well is used for the storage of cold water, the other one for the storage of heat. In warm seasons, cold water is extracted from the cold well to provide cooling to a building. The temperature of the extracted cold water increases as it passes through the building climate control systems and then gets simultaneously, injected back into the warm well. This procedure is reversed during cold seasons where the flow direction is reversed such that the warmer water is extracted from the warm well to provide heating to a building. From the perspective of building climate comfort systems, an ATES system is considered as a seasonal storage system that can be a heat source or sink, or as a storage for thermal energy. This leads to an interesting and challenging optimal control problem of the building climate comfort system that can be used to develop a seasonal-based energy management strategy. In [1] we develop a control-oriented model to predict thermal energy balance in a building climate control system integrated with ATES. Such a model however cannot cope with off-nominal but realistic situations such as when the wells are completely depleted, or the start-up phase of newly installed wells, etc., leading to direct usage of aquifer ambient temperature. Building upon our previous work in [1], we here extend the mathematical model for ATES system to handle the above mentioned more realistic situations. Using our improved models, one can more precisely predict system behavior and apply optimal control strategies to manage the building climate comfort along with energy savings and greenhouse gas reductions

  17. Defining The Energy Saving Potential of Architectural Design

    DEFF Research Database (Denmark)

    Naboni, Emanuele; Malcangi, Antonio; Zhang, Yi

    2015-01-01

    behaviour. The research shows the best solution for each of the climates and compares them with Olgyay´s findings. Finally, for each climate the energy saving potential is defined and then compared to Lechner's conclusions. Defining The Energy Saving Potential of Architectural Design (PDF Download Available......Designers, in response to codes or voluntary " green building " programs, are increasingly concerned with building energy demand reduction, but they are not fully aware of the energy saving potential of architectural design. According to literature, building form, construction and material choices......). Available from: https://www.researchgate.net/publication/279885641_Defining_The_Energy_Saving_Potential_of_Architectural_Design [accessed Jan 21, 2016]....

  18. Thermal energy storage

    Science.gov (United States)

    1980-01-01

    The planning and implementation of activities associated with lead center management role and the technical accomplishments pertaining to high temperature thermal energy storage subsystems are described. Major elements reported are: (1) program definition and assessment; (2) research and technology development; (3) industrial storage applications; (4) solar thermal power storage applications; and (5) building heating and cooling applications.

  19. How to estimate realistic energy savings in Energy Performance Certificates

    DEFF Research Database (Denmark)

    Wittchen, Kim Bjarne; Altmann, Nagmeh; Berecová, Monika

    Given the fact that most MS use fixed or other kinds of default values as boundary condition input for energy performance calculations, it is not surprising that the calculated energy performance differs from the measured energy consumption. As a consequence, the calculated energy savings due....... Fixing the boundary conditions for the national standard EP calculations is highly important for the calculated energy performance and hence the EP requirement level that MS set. It has great influence on the EP if there are 2 or 4 persons in a house, and the same goes for the rest of the standard...... to the variation of boundary conditions (except climate data) and highlight differences in boundary conditions used in different MS. The traditional EP certification/benchmarking calculation methods in most cases overesti-mate energy consumption before renovation and underestimate energy consumption after...

  20. Household preferences for energy-saving measures : A conjoint analysis

    NARCIS (Netherlands)

    Poortinga, Wouter; Steg, Linda; Vlek, Charles; Wiersma, Gerwin

    Studies on household energy use generally focus on social and psychological factors influencing the acceptability of energy-saving measures. However, the influence of physical characteristics of energy-saving measures on their acceptability is largely ignored. In this study, preferences for

  1. Commercial Integrated Heat Pump with Thermal Storage --Demonstrate Greater than 50% Average Annual Energy Savings, Compared with Baseline Heat Pump and Water Heater (Go/No-Go) FY16 4th Quarter Milestone Report

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Bo [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Baxter, Van D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Rice, C. Keith [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Abu-Heiba, Ahmad [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-03-01

    For this study, we authored a new air source integrated heat pump (AS-IHP) model in EnergyPlus, and conducted building energy simulations to demonstrate greater than 50% average energy savings, in comparison to a baseline heat pump with electric water heater, over 10 US cities, based on the EnergyPlus quick-service restaurant template building. We also assessed water heating energy saving potentials using ASIHP versus gas heating, and pointed out climate zones where AS-IHPs are promising.

  2. Saving Korean Won 1.07 billion by energy saving movement in 1999

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-08-01

    Hyosung is the biggest thread manufacturing company in Korea and the fourth in the World. It has integrated production system from nylon, polyester, and spandex thread to tirecord, textile fabrics, carpet and dyeing. Hyosung Kumi 1 factory, the biggest PET thread manufacturer in Korea producing 600 ton per day, is a highly energy consuming factory consuming 16.2 billion of energy and 8% of its sales. However, it saved Korean Won 1.07 billion in 1999 by implementing energy saving steadily.

  3. Energy saving screen materials : measurement method of radiation exchange, air permeability and humidity transport and a calculation method for energy saving

    NARCIS (Netherlands)

    Hemming, Silke; Baeza Romero, Esteban; Mohammadkhani, Vida; Breugel, van Bram

    2017-01-01

    The objectives of the project were the quantifi cation of the greenhouse screen properties (emissivity and transmissivity for thermal infrared radiation, air permeability and humidity transport) and the determination of the total energy saving under defi ned conditions in order to be able to compare

  4. Energy-saving measures in multi-storage housing construction

    Directory of Open Access Journals (Sweden)

    Мария Дмитриевна Коровина

    2017-05-01

    Full Text Available In this article the main directions of energy saving in multi-storey housing construction and methods for increasing energy efficiency are considered. The main problems of implementing energy-saving measures were touched; the need for their analysis during the development of each construction project with a view to choosing the most effective complex from the energy, economic, ecological and social points of view was justified. It is noted that such an approach can become an important factor of saving energy in the sphere of housing construction and reducing the energy intensity of the entire Russian economy.

  5. Demonstration of energy savings of cool roofs

    Energy Technology Data Exchange (ETDEWEB)

    Konopacki, S.; Gartland, L.; Akbari, H. [Lawrence Berkeley National Lab., CA (United States). Environmental Energy Technologies Div.; Rainer, L. [Davis Energy Group, Davis, CA (United States)

    1998-06-01

    Dark roofs raise the summertime air-conditioning demand of buildings. For highly-absorptive roofs, the difference between the surface and ambient air temperatures can be as high as 90 F, while for highly-reflective roofs with similar insulative properties, the difference is only about 20 F. For this reason, cool roofs are effective in reducing cooling energy use. Several experiments on individual residential buildings in California and Florida show that coating roofs white reduces summertime average daily air-conditioning electricity use from 2--63%. This demonstration project was carried out to address some of the practical issues regarding the implementation of reflective roofs in a few commercial buildings. The authors monitored air-conditioning electricity use, roof surface temperature, plenum, indoor, and outdoor air temperatures, and other environmental variables in three buildings in California: two medical office buildings in Gilroy and Davis and a retail store in San Jose. Coating the roofs of these buildings with a reflective coating increased the roof albedo from an average of 0.20--0.60. The roof surface temperature on hot sunny summer afternoons fell from 175 F--120 F after the coating was applied. Summertime average daily air-conditioning electricity use was reduced by 18% (6.3 kWh/1000ft{sup 2}) in the Davis building, 13% (3.6 kWh/1000ft{sup 2}) in the Gilroy building, and 2% (0.4 kWh/1000ft{sup 2}) in the San Jose store. In each building, a kiosk was installed to display information from the project in order to educate and inform the general public about the environmental and energy-saving benefits of cool roofs. They were designed to explain cool-roof coating theory and to display real-time measurements of weather conditions, roof surface temperature, and air-conditioning electricity use. 55 figs., 15 tabs.

  6. Energy saving obligations—cutting the Gordian Knot of leverage?

    OpenAIRE

    Rohde, Clemens; Rosenow, Jan; Eyre, Nick; Giraudet, Louis-Gaëtan

    2015-01-01

    International audience; Better leverage of public funding is essential in order to trigger the invest-ment needed for energy efficiency. In times of austerity governments in-creasingly look at policy instruments not funded by public expenditure and Energy Savings Obligations represent one option. Because Energy Savings Obligations are paid for by all energy customers, the degree to which they are able to raise additional private capital for energy efficiency invest-ments is crucial with regar...

  7. Saving energy through improving convection in a muffle furnace

    Directory of Open Access Journals (Sweden)

    Minea Adriana Alina

    2008-01-01

    Full Text Available Incompressible forced convection heat transfer problems normally admit an extremely important simplification: the fluid flow problem can be solved without reference to the temperature distribution in the fluid. Thus, it can first find the velocity distribution and then put it in the energy equation as known information and solve for the temperature distribution. In this paper it is intended to expand the theoretic researches concerning heat processes intensification and their use in industrial practice. In conclusion the fundamental research with concrete technical applications represents a significant contribution to the development of knowledge in domain. By centralizing the experimental results, there can be said that there has been obtained an energetic saving of approximate 20% by using radiant panels. By fitting the experimental data there has been obtained an optimum of the panels' positioning of x = 118.71 mm. In conclusion, changing the working space by introducing some radiant panels inside the furnace leads to important energy savings in the heating process, by increasing the heating rate of charge and by decreasing its residence time in the thermal equipment.

  8. Implementation of Energy Saving Controller for Electromagnetic Ballast Fluorescent Lamps

    Science.gov (United States)

    Xiong, Zhi; Barsoum, Cheong; Barsoum, N. N.

    2010-06-01

    Fluorescent lamps have proven to be the most efficient lighting device. However, energy losses have been found in electromagnetic ballast due to high harmonic distortion and low power factor so energy is consumed unnecessarily. In today's energy demanding environment, energy efficiency of fluorescent lamps can be improved by introducing an energy saving controller in the electromagnetic ballast. The energy saving controller limits the supply voltage to an optimum level which tends to reduce the power losses in electromagnetic ballasts and fluorescent lamps. It is also anticipated that the energy saving controller has desirable characteristics of high power factor with dimmable illuminance level control. In comparison to electronic dimmable ballast, integration an energy saving controller with electromagnetic ballast fluorescent lamps results in less power consumption, dimmable illuminance control and longer life span at a much lower installation cost. Furthermore, there is no replacement cost for integrating the energy saving controller with existing electromagnetic fluorescent lamps system. In this paper, experimental works have been performed to investigate hardware implementation of the system which further supported by simulation on MATLAB Simulink. Experimental results based on the proposed energy saving controller showed that electromagnetic ballast fluorescent lamps can be dimmed without any problems down to 50% illuminance level output. In addition, experimental results show that 37.5% power consumption can be saved by reducing 15% of the supply voltage.

  9. Energy-Saving Opportunities for Manufacturing Enterprises (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    2010-05-01

    This fact sheet English/Chinese describes the Industrial Technologies Program Save Energy Now model and provides information on tools and resources to help Chinese manufacturing enterprises reduce industrial energy intensity.

  10. Energy-Saving behaviour: Negative spillover to policy

    Science.gov (United States)

    Raimi, Kaitlin T.

    2017-07-01

    Individuals are often asked to reduce their home energy consumption. But new research suggests that reminders of these personal energy savings may undermine public support for national-level policies.

  11. Advisor about energy saving, saving money; Ratgeber zum Thema Energiesparen, Geld sparen

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    Energy saving is worthwhile in various ways: One saves money, preserves the environment and simultaneously contributes to climate protection. There are numerous possibilities of the energy conservation. The handbook under consideration is to help to survey the variety of measures of modernization and to enable the optimal decision. In addition, the handbook contains numerous practical hints, how the everyday consumption of electricity can be lowered as simply and fast as possible and the environment can be protected effectively.

  12. The influence of an estimated energy saving due to natural ventilation on the Mexican energy system

    DEFF Research Database (Denmark)

    Oropeza-Perez, Ivan; Østergaard, Poul Alberg

    2014-01-01

    This article shows the impacts of the extensive use of NV (natural ventilation) in the Mexican residential sector on the Mexican energy system. By integrating a thermal-airflow simulation programme with an energy systems analysis model, the impact on the Mexican energy system of replacing air...... conditioning, in particular, with natural ventilation to cool residential buildings is determined. It is shown that when, as in Mexico, there is a relatively simple connection between supply and electricity demand, NV creates savings which could be used to reduce either the fossil-fuel-based generation...

  13. The savings of energy saving: quantifying interactions between energy supply and demand side policies for Portugal

    Energy Technology Data Exchange (ETDEWEB)

    Simoes, Sofia; Seixas, Julia; Cleto, Joao; Fortes, Patricia (DCEA, New Univ. of Lisbon, GASA DCEA, FCT/UNL (Portugal))

    2009-07-01

    Defendants of energy efficiency have argued that policy-makers focus excessively on the 'trendier' energy supply and not enough on end-use energy efficiency. Focusing on supply side energy policies, as is the case of supporting large renewable electricity generation plants, without looking at the same time for the opportunities in the demand-side, may generate avoidable costs. This paper addresses the interactions between energy supply and demand side policies, by estimating the gains of end-use energy-efficiency and renewable applications in terms of (i) avoided electricity generation installed capacity, (ii) final energy consumption, (iii) share of renewables in final energy, as defined in the EU 'Climate action and renewable energy package', and also, (iv) reductions of greenhouse gases (GHG) emissions. The Portuguese energy system is used as a case-study, and the linear optimization technology TIMES{sub PT} model is used to generate four scenarios up to 2020 corresponding to different levels of penetration of efficient equipment, particularly in the commercial and residential sectors. In the two business-as-usual scenarios, the replacement of equipments from 2005 to 2020 follows the 2000-2005 trends and the National Energy Efficiency Action Plan targets. In the efficient scenarios all equipments can be replaced with more efficient ones. Results show that aggressive industry, residential and commercial demand-side measures can make unnecessary to increase the renewable electricity installed capacity in approximately 4.7GW as currently discussed by policy-makers, in order to meet the 31% target of share of renewables. These measures lead to a reduction of only 0-2% of total final energy, but this represents reduction of 11-14% in the commercial sector, and 1-4% in industry, with savings in total energy system costs of approximately 3000 M Euro - roughly the equivalent to 2% of the 2005 GDP.

  14. Energy-saving measures in multi-storage housing construction

    OpenAIRE

    Мария Дмитриевна Коровина; Полина Сергеевна Барашкова

    2017-01-01

    In this article the main directions of energy saving in multi-storey housing construction and methods for increasing energy efficiency are considered. The main problems of implementing energy-saving measures were touched; the need for their analysis during the development of each construction project with a view to choosing the most effective complex from the energy, economic, ecological and social points of view was justified. It is noted that such an approach can become an important factor ...

  15. Breakthrough Energy Savings with Waterjet Technology

    Energy Technology Data Exchange (ETDEWEB)

    Lee W. Saperstein; R. Larry Grayson; David A. Summers; Jorge Garcia-Joo; Greg Sutton; Mike Woodward; T.P. McNulty

    2007-05-15

    Experiments performed at the University of Missouri-Rolla's Waterjet Laboratory have demonstrated clearly the ability of waterjets to disaggregate, in a single step, four different mineral ores, including ores containing iron, lead and copper products. The study focused mainly on galena-bearing dolomite, a lead ore, and compared the new technology with that of traditional mining and milling to liberate the valuable constituent for the more voluminous host rock. The technical term for the disintegration of the ore to achieve this liberation is comminution. The potential for energy savings if this process can be improved, is immense. Further, if this separation can be made at the mining face, then the potential energy savings include avoidance of transportation (haulage and hoisting) costs to move, process and store this waste at the surface. The waste can, instead, be disposed into the available cavities within the mine. The savings also include the elimination of the comminution, crushing and grinding, stages in the processing plant. Future prototype developments are intended to determine if high-pressure waterjet mining and processing can be optimized to become cheaper than traditional fragmentation by drilling and blasting and to optimize the separation process. The basic new mining process was illustrated in tests on two local rock types, a low-strength sandstone with hematite inclusions, and a medium to high-strength dolomite commonly used for construction materials. Illustrative testing of liberation of minerals, utilized a lead-bearing dolomite, and included a parametric study of the optimal conditions needed to create a size distribution considered best for separation. The target goal was to have 50 percent of the mined material finer than 100 mesh (149 microns). Of the 21 tests that were run, five clearly achieved the target. The samples were obtained as run-of-mine lumps of ore, which exhibited a great deal of heterogeneity within the samples. This

  16. Comparative study of energy saving light sources

    Energy Technology Data Exchange (ETDEWEB)

    Khan, N.; Abas, N. [Department of Electrical Engineering, Comsats Institute of Information technology, Park Road, Islamabad (Pakistan)

    2011-01-15

    Techno-economic performance comparison of compact fluorescent lamps (CFL) with light emitting diodes (LED), electrode less fluorescent lamps (EEFL), fluorescent tubes, incandescent bulbs, photovoltaic (PV) and fiber optic lighting systems was carried out in view of worsening power and energy crisis in Pakistan. Literature survey showed 23 W CFL, 21 W EEFL, 18 W fluorescent tube or 15 W LED lamps emit almost same quantity of luminous flux (lumens) as a standard 100 W incandescent lamp. All inclusive, operational costs of LED lamps were found 1.21, 1.62. 1.69, 6.46, 19.90 and 21.04 times lesser than fluorescent tubes, CFL, EEFL, incandescent bulbs, fiber optic solar lighting and PV systems, respectively. However, tubes, LED, CFL and EEFL lamps worsen electric power quality of low voltage networks due to high current harmonic distortions (THD) and poor power factors (PF). Fluorescent lamps emit UV and pollute environment by mercury and phosphors when broken or at end of their life cycle. Energy consumption, bio-effects, and environmental concerns prefer LED lamps over phosphor based lamps but power quality considerations prefer EEFL. CFL and EEFL manufacturers claim operating temperatures in range of -20 C < T{sub CFL} < 60 C and -30 C < T{sub CFL} < 50 C but CFL frequently damage in wet and damp locations. Costs of low THD and high PF CFL, EEFL and LED lamps may be five to ten times higher that high THD and low PF lamps. Choice of a lamp depends upon its current THD, PF, life span, energy consumption, efficiency, efficacy, color rendering index (CRI) and associated physical effects. This work proposes manufacturing and user level innovations to get rid of low PF problems. Keeping in view downside of phosphor based lamps our research concludes widespread adoption of LED lamps. Government and commercial buildings may consider full spectrum hybrid thermal photovoltaic and solar fiber optic illumination systems. (author)

  17. Large Hospital 50% Energy Savings: Technical Support Document

    Energy Technology Data Exchange (ETDEWEB)

    Bonnema, E.; Studer, D.; Parker, A.; Pless, S.; Torcellini, P.

    2010-09-01

    This Technical Support Document documents the technical analysis and design guidance for large hospitals to achieve whole-building energy savings of at least 50% over ANSI/ASHRAE/IESNA Standard 90.1-2004 and represents a step toward determining how to provide design guidance for aggressive energy savings targets. This report documents the modeling methods used to demonstrate that the design recommendations meet or exceed the 50% goal. EnergyPlus was used to model the predicted energy performance of the baseline and low-energy buildings to verify that 50% energy savings are achievable. Percent energy savings are based on a nominal minimally code-compliant building and whole-building, net site energy use intensity. The report defines architectural-program characteristics for typical large hospitals, thereby defining a prototype model; creates baseline energy models for each climate zone that are elaborations of the prototype models and are minimally compliant with Standard 90.1-2004; creates a list of energy design measures that can be applied to the prototype model to create low-energy models; uses industry feedback to strengthen inputs for baseline energy models and energy design measures; and simulates low-energy models for each climate zone to show that when the energy design measures are applied to the prototype model, 50% energy savings (or more) are achieved.

  18. Energy Savers---Tips on Saving Energy and Money at Home (Fifth Printing)

    Energy Technology Data Exchange (ETDEWEB)

    DOE Office of Building Technology, State and Community Programs

    2001-08-13

    Provides consumers with home energy and money savings tips such as insulation, weatherization, heating, cooling, water heating, energy efficient windows, landscaping, lighting, and energy efficient appliances.

  19. FEMP: Seven steps to saving: How to implement energy-saving projects

    Energy Technology Data Exchange (ETDEWEB)

    Pitchford, P.

    1999-05-26

    The Energy Policy Act of 1992 and supporting Executive Orders have directed Federal agencies to implement cost-effective energy and water efficient measures to help conserve natural resources and protect the environment. Federal energy and facility managers can make a big difference. DOE's Federal Energy Management Program (FEMP) has outlined seven steps on how to implement an energy-saving project.

  20. Energy Costs of Energy Savings in Buildings: A Review

    Directory of Open Access Journals (Sweden)

    Daniel Rousse

    2012-08-01

    Full Text Available It is often claimed that the cheapest energy is the one you do not need to produce. Nevertheless, this claim could somehow be unsubstantiated. In this article, the authors try to shed some light on this issue by using the concept of energy return on investment (EROI as a yardstick. This choice brings semantic issues because in this paper the EROI is used in a different context than that of energy production. Indeed, while watts and negawatts share the same physical unit, they are not the same object, which brings some ambiguities in the interpretation of EROI. These are cleared by a refined definition of EROI and an adapted nomenclature. This review studies the research in the energy efficiency of building operation, which is one of the most investigated topics in energy efficiency. This study focuses on the impact of insulation and high efficiency windows as means to exemplify the concepts that are introduced. These results were normalized for climate, life time of the building, and construction material. In many cases, energy efficiency measures imply a very high EROI. Nevertheless, in some circumstances, this is not the case and it might be more profitable to produce the required energy than to try to save it.

  1. Bandwidth Study on Energy Use and Potential Energy Savings Opportunities in U.S. Petroleum Refining

    Energy Technology Data Exchange (ETDEWEB)

    Sabine Brueske, Caroline Kramer, Aaron Fisher

    2015-06-01

    Energy bandwidth studies of U.S. manufacturing sectors can serve as foundational references in framing the range (or bandwidth) of potential energy savings opportunities. This bandwidth study examines energy consumption and potential energy savings opportunities in U.S. petroleum refining. The study relies on multiple sources to estimate the energy used in nine individual process areas, representing 68% of sector-wide energy consumption. Energy savings opportunities for individual processes are based on technologies currently in use or under development; these potential savings are then extrapolated to estimate sector-wide energy savings opportunity.

  2. Bandwidth Study on Energy Use and Potential Energy Saving Opportunities in U.S. Chemical Manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    Sabine Brueske, Caroline Kramer, Aaron Fisher

    2015-06-01

    Energy bandwidth studies of U.S. manufacturing sectors can serve as foundational references in framing the range (or bandwidth) of potential energy savings opportunities. This bandwidth study examines energy consumption and potential energy savings opportunities in U.S. chemical manufacturing. The study relies on multiple sources to estimate the energy used in the production of 74 individual chemicals, representing 57% of sector-wide energy consumption. Energy savings opportunities for individual chemicals and for 15 subsectors of chemicals manufacturing are based on technologies currently in use or under development; these potential savings are then extrapolated to estimate sector-wide energy savings opportunity.

  3. Energy-saving Lighting Technology of Petrochemical Enterprises

    Directory of Open Access Journals (Sweden)

    Baohu Gu

    2015-12-01

    Full Text Available The shortage of energy resources is a serious problem our country is facing the world today, petrochemical enterprises are the main pillar of our economy, in our country, because petrochemical companies accounted for about 30.2% of the total energy consumption of energy. This paper focuses on the traditional energy-saving lighting methods proposed intelligent energy-saving system based on a fuzzy control. The purpose is to make the electrical equipment to fully meet, under the premise of improving its functional requirements, as far as possible to reduce energy consumption and improve energy efficiency.

  4. Ore concentrate line efficient operation: some energy saving implications

    Energy Technology Data Exchange (ETDEWEB)

    Ihle, Christian F. [BRASS Engineering Chile S.A., Santiago (Chile)

    2009-07-01

    Among the outstanding attributes slurry pipelines must have is the need to optimize production efficiency and, in particular, minimize energy consumption. In the present paper, the energy saving implications of three different factors, namely process variable uncertainties, transport control variables and pipeline availability are referred to and exemplified using an idealized Bingham-type slurry pipeline. Present examples suggest that important energy savings can be achieved with proper designs, equipment and operations scheduling. (author)

  5. Energy-saving options for the mitigation of greenhouse gas emissions from the Mongolian energy sector

    Energy Technology Data Exchange (ETDEWEB)

    Dorjpurev, J.; Purevjal, O.; Erdenechimeg, Ch. [and others

    1996-12-31

    The Energy sector is the largest contributor to GHG emission in Mongolia. The Energy sector emits 54 percent of CO2 and 4 percent of methane. All emissions of other greenhouse gases are accounted from energy related activities. The activities in this sector include coal production, fuel combustion, and biomass combustion at the thermal power stations and in private houses (stoves) for heating purposes. This paper presents some important Demand-side options considered for mitigation of CO2 emissions from energy sector such as Energy Conservation in Industrial Sector and in Buildings. Changes in energy policies and programmes in the Mongolian situation that promote more efficient and sustainable practices are presented in the paper. These energy saving measures will not only help reduce greenhouse gas emissions, but will also promote economic development and alleviate other environmental problems.

  6. Advanced Energy Saving and its Applications in Industry

    CERN Document Server

    Matsuda, Kazuo; Fushimi, Chihiro; Tsutsumi, Atsushi; Kishimoto, Akira

    2013-01-01

    The conventional approach for energy saving in a process system is to maximize heat recovery without changing any process conditions by using pinch technology. “Self-heat recuperation technology” was developed to achieve further energy saving in the process system by eliminating the necessity for any external heat input, such as firing or imported steam. Advanced Energy Saving and its Applications in Industry introduces the concept of self-heat recuperation and the application of such technology to a wide range of processes from heavy chemical complexes to other processes such as drying and gas separation processes, which require heating and cooling during operation.   Conventional energy saving items in a utility system are applied and implemented based on a single site approach, however, when looking at heavy chemical complexes, it was apparent that the low-grade heat discharged as waste from a refinery could also be used in an adjacent petrochemical plant. There could therefore be a large energy savin...

  7. Technical Support Document: 50% Energy Savings for Small Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Thornton, Brian A.; Wang, Weimin; Huang, Yunzhi; Lane, Michael D.; Liu, Bing

    2010-04-30

    The Technical Support Document (TSD) for 50% energy savings in small office buildings documents the analysis and results for a recommended package of energy efficiency measures (EEMs) referred to as the advanced EEMs. These are changes to a building design that will reduce energy usage. The package of advanced EEMs achieves a minimum of 50% energy savings and a construction area weighted average energy savings of 56.6% over the ANSI/ASHRAE/IESNA Standard 90.1-2004 for 16 cities which represent the full range of climate zones in the United States. The 50% goal is for site energy usage reduction. The weighted average is based on data on the building area of construction in the various climate locations. Cost-effectiveness of the EEMs is determined showing an average simple payback of 6.7 years for all 16 climate locations. An alternative set of results is provided which includes a variable air volume HVAC system that achieves at least 50% energy savings in 7 of the 16 climate zones with a construction area weighted average savings of 48.5%. Other packages of EEMs may also achieve 50% energy savings; this report does not consider all alternatives but rather presents at least one way to reach the goal. Design teams using this TSD should follow an integrated design approach and utilize additional analysis to evaluate the specific conditions of a project.

  8. Energy Saving Potential of PCMs in Buildings under Future Climate Conditions

    Directory of Open Access Journals (Sweden)

    Abdo Abdullah Ahmed Gassar

    2017-11-01

    Full Text Available Energy consumption reduction under changing climate conditions is a major challenge in buildings design, where excessive energy consumption creates an economic and environmental burden. Improving thermal performance of the buildings through support applying phase change material (PCM is a promising strategy for reducing building energy consumption under future climate change. Therefore, this study aims to investigate the energy saving potentials in buildings under future climate conditions in the humid and snowy regions in the hot continental and humid subtropical climates of the east Asia (Seoul, Tokyo and Hong Kong when various PCMs with different phase change temperatures are applied to a lightweight building envelope. Methodology in this work is implemented in two phases: firstly, investigation of energy saving potentials in buildings through inclusion of three types of PCMs with different phase temperatures into the building envelop separately and use weather file in the present (2017; and, secondly, evaluation of the effect of future climate change on the performance of PCMs by analyzing energy saving potentials of PCMs with 2020, 2050 and 2080 weather data. The results show that the inclusion of PCM into the building envelope is a promising strategy to increase the energy performance in buildings during both heating and cooling seasons in Seoul, Tokyo and Hong Kong under future climate conditions. The energy savings achieved by using PCMs in those regions are electricity savings of 4.48–8.21%, 3.81–9.69%, and 1.94–5.15%, and gas savings of 1.65–16.59%, 7.60–61.76%, and 62.07–93.33% in Seoul, Tokyo and Hong Kong, respectively, for the years 2017, 2020, 2050 and 2080. In addition, BioPCM and RUBITHERMPCM are the most efficient for improving thermal performance and saving energy in buildings in the tested regions and years.

  9. Multi-fuctional heat recovery systems. Really energy saving; Multifunktionale Waermerueckgewinnung. Wie man wirklich Energie spart

    Energy Technology Data Exchange (ETDEWEB)

    Schilling, Heinz [SEW Systemtechnik fuer Energierecycling und Waermeflussbegrenzung GmbH, Kempen (Germany)

    2009-10-15

    An energy saving leeds only to a correct optimized operation, if a demand-oriented total design is integrated into the building. In special for air-conditioning energy saving measures are presented and essential criteria named, to save in fact effectively, efficiently, reliably and profitably energy and enhance simultanously user quality. (orig./GL)

  10. the Use of Solar Light for Energy Saving

    Directory of Open Access Journals (Sweden)

    Antonio Peña-García

    2011-01-01

    Full Text Available Shifting the threshold zone of road tunnels with semitransparent tension structures has shown itself to be an effective way of saving energy in regards to electricity consumption, maintenance, and construction materials used in the electrical lighting, thus lessening negative environmental impacts. Even though the shape of the tension structure has a major influence on energy savings, the optimal type of structure for each tunnel is often difficult to determine, because experiments using real tunnels are extremely expensive. It is thus necessary to find methods of doing this that are both reliable as well as economical. In this research study, three candidate structures were set up at the portal of a scale model of a real tunnel. The energy savings in each case were analyzed and compared. As a result, it was possible to formulate a new equation that calculates the energy savings in the threshold zone.

  11. Effect of lifestyle on energy use estimations and predicted savings

    Energy Technology Data Exchange (ETDEWEB)

    Stovall, T.K.; Fuller, L.C.

    1988-03-01

    Audit predictions of energy-conservation savings are usually much higher than the savings actually achieved. Speculation about possible causes for this discrepancy has often centered around residents' lifestyle, specifically their indoor temperature management. Detailed indoor temperature data and extensive demographic information were available for 300 homes in Hood River, Oregon. These data were analyzed to examine the effect of demographic variables on indoor temperature and energy use. Changes in indoor temperature before and after retrofit were also examined. The effects of these variables were very small. Some small improvements to auditing procedures can be suggested based on this analysis. However, the major conclusion is that while some takeback of energy savings is occurring, it is very small in magnitude and cannot explain the large differences between predicted and achieved energy savings. 8 refs., 19 figs., 5 tabs.

  12. General Merchandise 50% Energy Savings Technical Support Document

    Energy Technology Data Exchange (ETDEWEB)

    Hale, E.; Leach, M.; Hirsch, A.; Torcellini, P.

    2009-09-01

    This report documents technical analysis for medium-box general merchandise stores aimed at providing design guidance that achieves whole-building energy savings of at least 50% over ASHRAE Standard 90.1-2004.

  13. Regional politics of energy savings and instruments of its realization

    Directory of Open Access Journals (Sweden)

    Simkiv Lilya Yevgenivna

    2016-02-01

    Full Text Available The article deals with theoretical and methodological foundations and applied aspects of the regional policy of energy saving aimed at the efficient use of energy resources in the region, diversification of energy supplies, modernization of energy infrastructure through the introduction of new technologies and protection of regional interests in the energy sector. The basic approaches and methods for the formation of regional policy of energy saving are determined. It allows deepening and expanding of the basic applied researches, and solving of more complex theoretical and applied problems of regional development. It is mentioned, that the development of regional energy saving policy involves the formation of appropriate legal, financial and credit policy; scientific research, economic, organizational and management measures; advertising and marketing support. It is proved, that for the practical implementation of regional policy the complex combination of economic feasibility, social effectiveness and environmental safety is required.

  14. Energy saving: From engineering to crop management

    NARCIS (Netherlands)

    Dieleman, J.A.; Hemming, S.

    2011-01-01

    In greenhouse horticulture, energy costs form an increasingly larger part of the total production costs. Energy is primarily used for temperature control, reduction of air humidity, increase of light intensity and CO2 supply. Use of fossil energy can be reduced by limiting the energy demand of the

  15. Potential for the Use of Energy Savings Performance Contracts to Reduce Energy Consumption and Provide Energy and Cost Savings in Non-Building Applications

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Charles; Green, Andrew S.; Dahle, Douglas; Barnett, John; Butler, Pat; Kerner, David

    2013-08-01

    The findings of this study indicate that potential exists in non-building applications to save energy and costs. This potential could save billions of federal dollars, reduce reliance on fossil fuels, increase energy independence and security, and reduce greenhouse gas emissions. The Federal Government has nearly twenty years of experience with achieving similar energy cost reductions, and letting the energy costs savings pay for themselves, by applying energy savings performance contracts (ESPC) inits buildings. Currently, the application of ESPCs is limited by statute to federal buildings. This study indicates that ESPCs can be a compatible and effective contracting tool for achieving savings in non-building applications.

  16. Investigating energy-saving potentials in the cloud.

    Science.gov (United States)

    Lee, Da-Sheng

    2014-02-20

    Collecting webpage messages can serve as a sensor for investigating the energy-saving potential of buildings. Focusing on stores, a cloud sensor system is developed to collect data and determine their energy-saving potential. The owner of a store under investigation must register online, report the store address, area, and the customer ID number on the electric meter. The cloud sensor system automatically surveys the energy usage records by connecting to the power company website and calculating the energy use index (EUI) of the store. Other data includes the chain store check, company capital, location price, and the influence of weather conditions on the store; even the exposure frequency of store under investigation may impact the energy usage collected online. After collecting data from numerous stores, a multi-dimensional data array is constructed to determine energy-saving potential by identifying stores with similarity conditions. Similarity conditions refer to analyzed results that indicate that two stores have similar capital, business scale, weather conditions, and exposure frequency on web. Calculating the EUI difference or pure technical efficiency of stores, the energy-saving potential is determined. In this study, a real case study is performed. An 8-dimensional (8D) data array is constructed by surveying web data related to 67 stores. Then, this study investigated the savings potential of the 33 stores, using a site visit, and employed the cloud sensor system to determine the saving potential. The case study results show good agreement between the data obtained by the site visit and the cloud investigation, with errors within 4.17%. Among 33 the samples, eight stores have low saving potentials of less than 5%. The developed sensor on the cloud successfully identifies them as having low saving potential and avoids wasting money on the site visit.

  17. Investigating Energy-Saving Potentials in the Cloud

    Directory of Open Access Journals (Sweden)

    Da-Sheng Lee

    2014-02-01

    Full Text Available Collecting webpage messages can serve as a sensor for investigating the energy-saving potential of buildings. Focusing on stores, a cloud sensor system is developed to collect data and determine their energy-saving potential. The owner of a store under investigation must register online, report the store address, area, and the customer ID number on the electric meter. The cloud sensor system automatically surveys the energy usage records by connecting to the power company website and calculating the energy use index (EUI of the store. Other data includes the chain store check, company capital, location price, and the influence of weather conditions on the store; even the exposure frequency of store under investigation may impact the energy usage collected online. After collecting data from numerous stores, a multi-dimensional data array is constructed to determine energy-saving potential by identifying stores with similarity conditions. Similarity conditions refer to analyzed results that indicate that two stores have similar capital, business scale, weather conditions, and exposure frequency on web. Calculating the EUI difference or pure technical efficiency of stores, the energy-saving potential is determined. In this study, a real case study is performed. An 8-dimensional (8D data array is constructed by surveying web data related to 67 stores. Then, this study investigated the savings potential of the 33 stores, using a site visit, and employed the cloud sensor system to determine the saving potential. The case study results show good agreement between the data obtained by the site visit and the cloud investigation, with errors within 4.17%. Among 33 the samples, eight stores have low saving potentials of less than 5%. The developed sensor on the cloud successfully identifies them as having low saving potential and avoids wasting money on the site visit.

  18. Investigating Energy-Saving Potentials in the Cloud

    Science.gov (United States)

    Lee, Da-Sheng

    2014-01-01

    Collecting webpage messages can serve as a sensor for investigating the energy-saving potential of buildings. Focusing on stores, a cloud sensor system is developed to collect data and determine their energy-saving potential. The owner of a store under investigation must register online, report the store address, area, and the customer ID number on the electric meter. The cloud sensor system automatically surveys the energy usage records by connecting to the power company website and calculating the energy use index (EUI) of the store. Other data includes the chain store check, company capital, location price, and the influence of weather conditions on the store; even the exposure frequency of store under investigation may impact the energy usage collected online. After collecting data from numerous stores, a multi-dimensional data array is constructed to determine energy-saving potential by identifying stores with similarity conditions. Similarity conditions refer to analyzed results that indicate that two stores have similar capital, business scale, weather conditions, and exposure frequency on web. Calculating the EUI difference or pure technical efficiency of stores, the energy-saving potential is determined. In this study, a real case study is performed. An 8-dimensional (8D) data array is constructed by surveying web data related to 67 stores. Then, this study investigated the savings potential of the 33 stores, using a site visit, and employed the cloud sensor system to determine the saving potential. The case study results show good agreement between the data obtained by the site visit and the cloud investigation, with errors within 4.17%. Among 33 the samples, eight stores have low saving potentials of less than 5%. The developed sensor on the cloud successfully identifies them as having low saving potential and avoids wasting money on the site visit. PMID:24561405

  19. Energy-saving strategies with personalized ventilation in cold climates

    DEFF Research Database (Denmark)

    Shiavon, Stefano; Melikov, Arsen Krikor

    2009-01-01

    In this study the influence of the personalized supply air temperature control strategy on energy consumption and the energy-saving potentials of a personalized ventilation system have been investigated by means of simulations with IDA-ICE software. GenOpt software was used to determine the optimal...... supply air temperature. The simulated office room was located in a cold climate. The results reveal that the supply air temperature control strategy has a marked influence on energy consumption. The energy consumption with personalized ventilation may increase substantially (in the range: 61......–268%) compared to mixing ventilation alone if energy-saving strategies are not applied. The results show that the best supply air temperature control strategy is to provide air constantly at 20 °C. The most effective way of saving energy with personalized ventilation is to extend the upper room operative...

  20. Problems of Technology of Energy-Saving Buildings and Their Impact on Energy Efficiency in Buildings

    Science.gov (United States)

    Kwasnowski, Pawel; Fedorczak-Cisak, Malgorzata; Knap, Katarzyna

    2017-10-01

    Introduction of EPBD in legislation of the EU member states caused that buildings must meet very stringent requirements of thermal protection and energy efficiency. On the basis of EPBD provisions, EU Member States introduce standard of NZEB (Nearly Zero-Energy Buildings). Such activities cause a need for new, innovative materials and technologies, and new approaches to design, construction and retrofitting of buildings. Indispensable is the precise coordination of the design of structure and technical installations of building, which may be provided in an integrated design process in the system BIM. Good coordination and cooperation of all contractors during the construction phase is also necessary. The article presents the problems and the new methodology for the design, construction and use of energy efficient buildings in terms of energy saving technologies, including discussion of the significant impact of the automation of technical installations on the building energy efficiency.

  1. Energy Savings Performance Contracts (ESPC): Frequently Asked Questions

    Energy Technology Data Exchange (ETDEWEB)

    None

    2012-11-01

    An ESPC is a working relationship between a Federal agency and an energy service company (ESCO). The ESCO conducts a comprehensive energy audit for the Federal facility and identifies improvements to save energy. The following sections present a number of frequently asked questions from ESPC end-users and stakeholders.

  2. Computational Support for the Selection of Energy Saving Building Components

    NARCIS (Netherlands)

    De Wilde, P.J.C.J.

    2004-01-01

    Buildings use energy for heating, cooling and lighting, contributing to the problems of exhaustion of fossil fuel supplies and environmental pollution. In order to make buildings more energy-efficient an extensive set of âenergy saving building componentsâ has been developed that contributes to

  3. What Are Schools Doing to Save Energy?

    Science.gov (United States)

    Fredrickson, John H.

    Many school districts are still approaching the energy crisis as though it were a temporary inconvenience. However, school districts that have recognized the gravity of the energy situation have conducted energy audits. Basically, there are two types of audits. The first is a simple walk through each building using a checklist format. The second…

  4. Passive Collecting of Solar Radiation Energy using Transparent Thermal Insulators, Energetic Efficiency of Transparent Thermal Insulators

    OpenAIRE

    Smajo Sulejmanovic; Suad Kunosic; Ema Hankic

    2014-01-01

    This paper explains passive collection of solar radiation energy using transparent thermal insulators. Transparent thermal insulators are transparent for sunlight, at the same time those are very good thermal insulators. Transparent thermal insulators can be placed instead of standard conventional thermal insulators and additionally transparent insulators can capture solar radiation, transform it into heat and save heat just as standard insulators. Using transparent insulators would lead to r...

  5. Health Externalities and Heat savings in Energy System Modelling

    DEFF Research Database (Denmark)

    Zvingilaite, Erika

    and included in an energy system optimisation model. The performed analysis of the Danish heat and power sector concludes that accounting for spatial variation of health damage costs in heat and power system optimisation model has an effect on the optimal technology mix and distribution of energy plants among...... and technologies, more remote location of energy plants and by reducing energy consumption. Considerable technical potential for energy demand reduction exists, particularly in buildings. In countries with cold climate, such as Denmark, energy demand for heating of buildings accounts for a significant share...... of the total energy consumption. Due to the long lifetime of buildings, they are an important part of the futureenergy systems. However, energy system studies often treat energy consumption and energy savings in buildings exogenously. At the same time heat savings in buildings are usually examined separately...

  6. Quantifying the savings of an industry energy efficiency programme

    Energy Technology Data Exchange (ETDEWEB)

    Cahill, C.J. [Sustainable Energy Research Group, Department of Civil and Environmental Engineering, University College Cork, Cork (Ireland); Gallachoir, B.P.O. [Environmental Research Institute, University College Cork, Lee Road, Cork (Ireland)

    2012-05-15

    In a developed economy, improving the energy performance of the industry sector can make an important contribution to achieving national energy efficiency goals. Policy measures aimed at increasing energy efficiency in industry must be proven to be effective. In Ireland one such measure is the Large Industry Energy Network (LIEN) programme. LIEN is a voluntary network of large energy users, facilitated by the national energy agency, working to maintain strong energy management practices. In this paper, we combine top-down methods for analysing national energy statistics with company-level figures supplied by LIEN participants to quantify the energy savings achieved by the companies and to determine the fraction of national savings that can be attributed to them. By comparing the collective performance of participant companies with the performance of the rest of industry we provide an indication of the effectiveness of the programme and quantify the savings that may be directly attributable to it. These figures when combined with national energy forecasts for industry help us assess the likely contribution of the programme to future national energy savings targets.

  7. Predictive Maintenance (PdM) Centralization for Significant Energy Savings

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Dale

    2010-09-15

    Cost effective predictive maintenance (PdM) technologies and basic energy calculations can mine energy savings form processes or maintenance activities. Centralizing and packaging this information correctly empowers facility maintenance and reliability professionals to build financial justification and support for strategies and personnel to weather global economic downturns and competition. Attendees will learn how to: Systematically build a 'pilot project' for applying PdM and tracking systems; Break down a typical electrical bill to calculate energy savings; Use return on investment (ROI) calculations to identify the best and highest value options, strategies and tips for substantiating your energy reduction maintenance strategies.

  8. Energy saving strategies in an actual confectionery plant

    Energy Technology Data Exchange (ETDEWEB)

    Grimaldi, C.N.; Lunghi, P.; Mariani, F. [Universita di Perugia, Dip. di Ingegneria Industriale, Perugia (Italy)

    2000-07-01

    The achievements of a more rational use of energy can be difficult when large and complex industrial plants are considered. In the present work, an example is given of how a well-focused energy analysis, based on experimental data, can help to point out possible relevant energy savings. In particular, two different refrigeration systems have been examined for a confectionery plant in different seasons, atmospheric and production conditions, allowing us to understand the actual operation. Based on the analysis of the results, energy saving strategies have been proposed and discussed. (Author)

  9. Energy-Saving in Brew-Rectification

    Directory of Open Access Journals (Sweden)

    N. I. Ulyanau

    2008-01-01

    Full Text Available The paper investigates dynamics of rectification process on one plate of a column. The basic channels controlling brew-rectification process are described in the paper.The paper also considers problems pertaining to synthesis of an adaptive system that controls non-stationary objects with delay. Synthesis of adaptive systems that automatically control product quality and saving on power resources and productivity with the help of the second method of Lyapunov has been carried out in the paper.Industrial introduction of the given automatic control system of technological process shall permit to increase productivity of a rectification (10–15 %, to decrease specific power consumption by (5–10 % while preserving the specified quality of rectified ethyl alcohol and decrease alcohol losses with luting water and malt-residue.

  10. Opportunities of energy saving in lighting systems for public buildings

    Directory of Open Access Journals (Sweden)

    Ayman Abd El-khalek

    2017-03-01

    Full Text Available The lighting system provides many options for cost-effective energy saving with low or no inconvenience. Lighting improvements are excellent investments in most public buildings, it is usually cost-effective to address because lighting improvements are often easier to make than many process upgrades.For public buildings, the easy no and low cost options to help save money and improve the energy performance are:Understand energy use.Identify optionsPrioritize actionsMake the changes and measure the savings.Continue managing energy efficiency.The challenge is to retrofit traditional lamps with LED lamps of good quality. The benefits of LED light bulbs are long-lasting, durable, cool, mercury free, more efficient, and cost effective.The light Emitting Diode (LED bulb uses a semiconductor as its light source, and is currently one of the most energy efficient and quickly developing types of bulbs for lighting. LEDs increasingly are being purchased to replace traditional bulbs. LEDs are relatively more expensive than other types of bulbs, but are very cost-effective because they use only a fraction of electricity of traditional lighting methods nd can last for longer.Benchmarking guides decision makers to policies aimed at the energy sector through better understanding of energy consumption trends nationwide, e.g.: energy price, moderating, peak demand, and encouraging sectors, low energy expansions.The “Improving Energy Efficiency Project of Lighting and Appliances” carried out energy audits and implemented opportunities of energy saving in lighting for different type of public buildings.To rationalize the use of energy by giving guidelines to consumers, the IEEL&A project prepared some brochures.This paper leads with the results of case studies as energy audits, opportunities in lighting systems, energy saving and CO2 reduction.

  11. Heat Saving Strategies in Sustainable Smart Energy Systems

    DEFF Research Database (Denmark)

    Lund, Henrik; Thellufsen, Jakob Zinck; Aggerholm, Søren

    One of the important issues related to the implementation of future sustainable smart energy systems based on renewable energy sources is the heating of buildings. Especially, when it comes to long‐term investment in savings and heating infrastructures it is essential to identify long‐term least...... that a least‐cost strategy will be to provide approximately 2/3 of the heat demand from district heating and the rest from individual heat pumps. Keywords: Energy Efficiency, Renewable energy, Heating strategy, Heat savings, District heating, Smart energy......‐cost strategies. With Denmark as a case, this paper investigates to which extent heat should be saved rather than produced and to which extent district heating infrastructures, rather than individual heating solutions, should be used. Based on a concrete proposal to implement the Danish governmental long...

  12. Energy saving certificates; Les certificats d'economies d'energie

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-11-15

    The French ministry of economy, finances and industry and the French agency of environment and energy mastery (Ademe) have organized on November 8, 2005, a colloquium for the presentation of the energy saving certificates, a new tool to oblige the energy suppliers to encourage their clients to make energy savings. This document gathers the transparencies presented at this colloquium about the following topics: state-of-the-art and presentation of the energy saving certificates system: presentation of the EEC system, presentation of the EEC standard operations; the energy saving certificates in Europe today: energy efficiency commitment in UK, Italian white certificate scheme, perspectives of the different European systems. (J.S.)

  13. Thermal Energy Conversion Branch

    Science.gov (United States)

    Bielozer, Matthew C.; Schreiber, Jeffrey, G.; Wilson, Scott D.

    2004-01-01

    The Thermal Energy Conversion Branch (5490) leads the way in designing, conducting, and implementing research for the newest thermal systems used in space applications at the NASA Glenn Research Center. Specifically some of the most advanced technologies developed in this branch can be broken down into four main areas: Dynamic Power Systems, Primary Solar Concentrators, Secondary Solar Concentrators, and Thermal Management. Work was performed in the Dynamic Power Systems area, specifically the Stirling Engine subdivision. Today, the main focus of the 5490 branch is free-piston Stirling cycle converters, Brayton cycle nuclear reactors, and heat rejection systems for long duration mission spacecraft. All space exploring devices need electricity to operate. In most space applications, heat energy from radioisotopes is converted to electrical power. The Radioisotope Thermoelectric Generator (RTG) already supplies electricity for missions such as the Cassini Spacecraft. The focus of today's Stirling research at GRC is aimed at creating an engine that can replace the RTG. The primary appeal of the Stirling engine is its high system efficiency. Because it is so efficient, the Stirling engine will significantly reduce the plutonium fuel mission requirements compared to the RTG. Stirling is also being considered for missions such as the lunar/Mars bases and rovers. This project has focused largely on Stirling Engines of all types, particularly the fluidyne liquid piston engine. The fluidyne was developed by Colin D. West. This engine uses the same concepts found in any type of Stirling engine, with the exception of missing mechanical components. All the working components are fluid. One goal was to develop and demonstrate a working Stirling Fluidyne Engine at the 2nd Annual International Energy Conversion Engineering Conference in Providence, Rhode Island.

  14. Integrated Thermal Energy Storage

    OpenAIRE

    Kopko, William L.

    2016-01-01

    Integrated Thermal Energy Storage (ITES) is a novel concept in improving cooling performance of air-conditioning systems at peak-load conditions. In contrast to conventional chilled-water or ice storage, it uses stored chilled water to subcool condenser refrigerant liquid instead of supplying cooling directly to a cooling load. For typical R-134a and R-410A systems, subcooling increases capacity by approximately .5 to .7%/°F (~.9 to 1.3 %/K) without increasing compressor input power. Even l...

  15. Energy Savings From System Efficiency Improvements in Iowa's HVAC SAVE Program

    Energy Technology Data Exchange (ETDEWEB)

    Yee, S. [Partnership for Advanced Residential Retrofit, Chicago, IL (United States); Baker, J. [Partnership for Advanced Residential Retrofit, Chicago, IL (United States); Brand, L. [Partnership for Advanced Residential Retrofit, Chicago, IL (United States); Wells, J. [Partnership for Advanced Residential Retrofit, Chicago, IL (United States)

    2013-08-01

    The objective of this project is to explore the energy savings potential of maximizing furnace and distribution system performance by adjusting operating, installation, and distribution conditions. The goal of the Iowa HVAC System Adjusted and Verified Efficiency (SAVE) program is to train contractors to measure installed system efficiency as a diagnostic tool to ensure that the homeowner achieves the energy reduction target for the home rather than simply performing a tune-up on the furnace or having a replacement furnace added to a leaky system. The PARR research team first examined baseline energy usage from a sample of 48 existing homes, before any repairs or adjustments were made, to calculate an average energy savings potential and to determine which system deficiencies were prevalent. The results of the baseline study of these homes found that, on average, about 10% of the space heating energy available from the furnace was not reaching the conditioned space. In the second part of the project, the team examined a sample of 10 homes that had completed the initial evaluation for more in-depth study. For these homes, the diagnostic data shows that it is possible to deliver up to 23% more energy from the furnace to the conditioned space by doing system tune ups with or without upgrading the furnace. Replacing the furnace provides additional energy reduction. The results support the author's belief that residential heating and cooling equipment should be tested and improved as a system rather than a collection of individual components.

  16. Keeping Energy Savings in the LOOP

    Energy Technology Data Exchange (ETDEWEB)

    Parrish, Kristen [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Mercado, Andrea [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-11-01

    Mesa Lane Partners (MLP) partnered with the U.S. Department of Energy (DOE) to develop and implement solutions to a build a new, low-energy mixed-use building that consumes at least 50% less energy than requirements set by Energy Standard 90.1-2007 of the American Society of Heating, Refrigerating, and Air-conditioning Engineers (ASHRAE), the American National Standards Institute (ANSI), and the Illuminating Engineering Society of America (IESNA), as part of DOE’s Commercial Building Partnerships (CBP)3 Program. Lawrence Berkeley National Laboratory (LBNL) provided technical expertise in support of this DOE program. The privately developed 46,000-square-foot LOOP project, which is intended to provide affordable off-campus student housing in an underserved community next to University of California at Santa Barbara, will contain more than 7,000 square feet of retail space, a roof deck, an event space, a gym, and 48 apartments. The project developer, MLP, is aiming to exceed CBP requirement, targeting energy consumption that is at least 65% less than that required by the standard. If the LOOP meets this goal, it is expected to achieve Leadership in Energy and Environmental Design (LEED) Gold certification. To meet this goal, the project design incorporates a variety of energy efficiency measures (EEMs) that address the needs of the multiple use types that the project will house.

  17. VO₂ thermochromic smart window for energy savings and generation.

    Science.gov (United States)

    Zhou, Jiadong; Gao, Yanfeng; Zhang, Zongtao; Luo, Hongjie; Cao, Chuanxiang; Chen, Zhang; Dai, Lei; Liu, Xinling

    2013-10-24

    The ability to achieve energy saving in architectures and optimal solar energy utilisation affects the sustainable development of the human race. Traditional smart windows and solar cells cannot be combined into one device for energy saving and electricity generation. A VO2 film can respond to the environmental temperature to intelligently regulate infrared transmittance while maintaining visible transparency, and can be applied as a thermochromic smart window. Herein, we report for the first time a novel VO2-based smart window that partially utilises light scattering to solar cells around the glass panel for electricity generation. This smart window combines energy-saving and generation in one device, and offers potential to intelligently regulate and utilise solar radiation in an efficient manner.

  18. Energy Savings for Solar Heating Systems

    DEFF Research Database (Denmark)

    Thür, Alexander; Furbo, Simon; Shah, Louise Jivan

    2006-01-01

    In this paper the realistic behaviour and efficiency of heating systems were analysed, based on long term monitoring projects. Based on the measurements a boiler model used to calculate the boiler efficiency on a monthly basis was evaluated. Comparisons of measured and calculated fuel consumptions...... showed a good degree of similarity. With the boiler model, various simulations of solar domestic hot water heating systems were done for different hot water demands and collector sizes. The result shows that the potential of fuel reduction can be much higher than the solar gain of the solar thermal...

  19. Energy Savings for Solar Heating Systems

    DEFF Research Database (Denmark)

    Thür, Alexander; Furbo, Simon; Shah, Louise Jivan

    2004-01-01

    In this paper the realistic behaviour and efficiency of heating systems were analysed, based on long term monitoring projects. Based on the measurements a boiler model was evaluated. Comparisons of measured and calculated fuel consumptions showed a good degree of similarity. With the boiler model......, various simulations of solar heating systems were done for different hot water demands and collector sizes. The result shows that the potential of fuel reduction can be much higher than the solar gain of the solar thermal system. For some conditions the fuel reduction can be up to the double of the solar...

  20. Waste energy harvesting mechanical and thermal energies

    CERN Document Server

    Ling Bing, Kong; Hng, Huey Hoon; Boey, Freddy; Zhang, Tianshu

    2014-01-01

    Waste Energy Harvesting overviews the latest progress in waste energy harvesting technologies, with specific focusing on waste thermal mechanical energies. Thermal energy harvesting technologies include thermoelectric effect, storage through phase change materials and pyroelectric effect. Waste mechanical energy harvesting technologies include piezoelectric (ferroelectric) effect with ferroelectric materials and nanogenerators. The book aims to strengthen the syllabus in energy, materials and physics and is well suitable for students and professionals in the fields.

  1. The Energy Smart Guide to Campus Cost Savings.

    Science.gov (United States)

    Department of Energy, Washington, DC. Office of Energy Efficiency and Renewable Energy.

    Rebuild America is a program of the U.S. Department of Energy that focuses on energy-savings solutions as community solutions. It works with K-12 schools, colleges and universities, state and local governments, public and multifamily housing, and commercial buildings. This guide focuses on colleges and universities. Each chapter spells out options…

  2. Water and energy saving bioprocess for bioethanol production from ...

    African Journals Online (AJOL)

    Water and energy saving bioprocess for bioethanol production from corn grain applying stillage liquid part recirculation. ... from corn constitutes the way which could significantly reduce the water and energy consumption, what essentially reduce whole general production costs without ethanol efficiency decreasing.

  3. Energy-saving wastewater treatment systems : formulation of cost functions

    OpenAIRE

    Nogueira, R.; Ferreira, I.; Janknecht, P; Rodríguez, Juan José; de Oliveira, Pedro; A. G. Brito

    2007-01-01

    Natural interactions between water, soil, atmosphere, plants and microorganisms include physical, chemical and biological processes with decontaminating capacities. Natural or energy-saving wastewater treatment systems utilize these processes and thereby enable a sustainable management in the field of wastewater treatment, offering low investment and operation costs, little or no energy consumption, little and low-skill labor requirements, good landscape integration and excellent ...

  4. Energy-saving technologies of cultivation of sugar sorghum

    Science.gov (United States)

    Kashapov, N. F.; Nafikov, M. M.; Gilmanshin, I. R.; Gazetdinov, M. Kh; Nafikova, M. M.; Nigmatzyanov, A. R.

    2017-09-01

    The article describes the main elements of energy-saving technologies of cultivation of sugar sorghum, which, in particular, is the introduction of the combined units. Integrated units allow for one pass across the field to perform up to eight operations, thereby ensuring a significant reduction in energy costs, but there are certain negative points.

  5. Vacuum Pump System Optimization Saves Energy at a Dairy Farm

    Energy Technology Data Exchange (ETDEWEB)

    None

    2001-08-01

    In 1998, S&S Dairy optimized the vacuum pumping system at their dairy farm in Modesto, California. In an effort to reduce energy costs, S&S Dairy evaluated their vacuum pumping system to determine if efficiency gains and energy savings were possible.

  6. Energy Savings Potential from Improved Building Controls for the U.S. Commercial Building Sector

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, Nicholas EP; Katipamula, Srinivas; Wang, Weimin; Xie, YuLong; Zhao, Mingjie

    2018-02-05

    %; seven of the nine building types were in the range of 23 to 29% and two exceeded 40%. The total potential national site savings in for each building type ranged between 95x106 GJ (0.09 Quadrillion British thermal units [Quads]; Large Hotels) to 222x106 GJ (0.21 Quads; Large Office, Hospital Administrative areas, and College/University), resulting in total site savings of 1,393x106 GJ (1.32 Quads) when the three packages are applied to the U.S. commercial buildings stock. Using the source (or primary) energy conversion factors of 1.05 for natural gas and 3.14 for electricity resulted in an approximate potential primary energy savings of 2,912x106 GJ (2.76 Quads), which would be 15% of the sector’s 2015 use of approximately 18,991x106 GJ (18 Quads). Extrapolating the results for other building types not analyzed as part of this study, the primary energy savings could be in the range of 4,220x106 GJ to 5,275x106 GJ (4 to 5 Quads). If this savings potential is realized, it would be equivalent to not combusting 180 to 230 million tons of coal or reducing the energy impacts, at today’s energy intensities, of the per capita consumption of 12 to 15 million people in the U.S. To realize most of this potential savings, many gaps can be addressed through RD&D, as recommended in this paper.

  7. High-Temperature Coatings Offer Energy Savings

    Science.gov (United States)

    2012-01-01

    The U.S. X-Plane Program included the first-of-its-kind research in aerodynamics and astronautics with experimental vehicles, including the first aircraft to break the sound barrier; the first aircraft to fly in excess of 100,000, then 200,000, and then 300,000 feet; and the first aircraft to fly at three, four, five, and then six times the speed of sound. During the 1990s, NASA started developing a new thermal protection material to test on the X-33 and X-34 supersonic aircraft. The X-33 was intended to demonstrate the technologies needed for a new reusable launch vehicle and was projected to reach an altitude of approximately 50 miles and speeds of more than Mach 11. The X-34, a small, reusable technology demonstrator for a launch vehicle, was intended to reach an altitude of 250,000 feet and fly at speeds of Mach 8. As a result of its research and development efforts, NASA s Ames Research Center invented the Protective Ceramic Coating Material (PCCM). Applied to a surface, the thin, lightweight coating could protect the material underneath from extreme temperatures. The capability of the technology came from its emissivity, which radiated heat away from the surface it covered, thereby decreasing the amount of heat transferred to the underlying material. PCCM not only increased the capability of materials to withstand higher temperatures, it also exhibited impressive thermal shock, vibration, and acoustic performance. In addition, it proved to be resistant to abrasion and mechanical damage and was also environmentally safe, due to it being water-based and containing no solvents. Even though funding for the X-33 and X-34 ended in 2001, PCCM continued on a path of innovation.

  8. Impacts of Commercial Building Controls on Energy Savings and Peak Load Reduction

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, Nicholas E.P. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Katipamula, Srinivas [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wang, Weimin [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Xie, YuLong [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhao, Mingjie [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Corbin, Charles D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-05-30

    Commercial buildings in the United States use about 18 Quadrillion British thermal units (Quads) of primary energy annually . Studies have shown that as much as 30% of building energy consumption can be avoided by using more accurate sensing, using existing controls better, and deploying advanced controls; hence, the motivation for the work described in this report. Studies also have shown that 10% to 20% of the commercial building peak load can be temporarily managed/curtailed to provide grid services. Although many studies have indicated significant potential for reducing the energy consumption in commercial buildings, very few have documented the actual savings. The studies that did so only provided savings at the whole building level, which makes it difficult to assess the savings potential of each individual measure deployed.

  9. Novel energy saving technologies evaluation tool

    NARCIS (Netherlands)

    Klemeš, J.; Bulatov, I.; Koppejan, J.

    2009-01-01

    The lead-time for the development of a new energy technology, from the initial idea to the commercial application, can take many years. The reduction of this time has been the main objective of the EC DGTREN, who have funded two related recent projects, EMINENT and EMINENT2 (Early Market

  10. Energy Saving Devices on Gas Furnaces.

    Science.gov (United States)

    1980-03-01

    DEVICES FOR GAS FURNACES THOMAS E. BRISBANE ,o"’ P. B. SHEPHERD JOHNS-MANVILLE SALES CORPORATION RESEARCH & DEVELOPMENT CENTER KEN- CARYL RANCH, DENVER...by Mr. Thomas E. Brisbane under the direction of Dr. S. Karaki, Professor of Civil Engineering and Director, Solar Energy Application Laboratory. Mr

  11. Does energy labelling on residential housing cause energy savings? Working paper

    Energy Technology Data Exchange (ETDEWEB)

    Kjaerbye, V.H.

    2008-12-15

    More than 80% of energy used in households is dedicated to space heating. Large potential energy savings have been identified in the existing housing stock. Energy labelling of single-family houses is seen as an important instrument to provide new house owners with information on efficient energy saving investments that can be made on the house. This paper evaluates the effects of the Danish Energy Labelling Scheme on energy consumption in existing single-family houses with propensity score matching using actual consumption of energy and register data describing the houses and households. We do not find significant energy savings due to the Danish Energy Labelling Scheme. (Author)

  12. Making the results of bottom-up energy savings comparable

    Directory of Open Access Journals (Sweden)

    Moser Simon

    2012-01-01

    Full Text Available The Energy Service Directive (ESD has pushed forward the issue of energy savings calculations without clarifying the methodological basis. Savings achieved in the Member States are calculated with rather non-transparent and hardly comparable Bottom-up (BU methods. This paper develops the idea of parallel evaluation tracks separating the Member States’ issue of ESD verification and comparable savings calculations. Comparability is ensured by developing a standardised BU calculation kernel for different energy efficiency improvement (EEI actions which simultaneously depicts the different calculation options in a structured way (e.g. baseline definition, system boundaries, double counting. Due to the heterogeneity of BU calculations the approach requires a central database where Member States feed in input data on BU actions according to a predefined structure. The paper demonstrates the proposed approach including a concrete example of application.

  13. Comparison of Software Models for Energy Savings from Cool Roofs

    Energy Technology Data Exchange (ETDEWEB)

    New, Joshua Ryan [ORNL; Miller, William A [ORNL; Huang, Yu (Joe) [White Box Technologies; Levinson, Ronnen [Lawrence Berkeley National Laboratory (LBNL)

    2014-01-01

    A web-based Roof Savings Calculator (RSC) has been deployed for the United States Department of Energy as an industry-consensus tool to help building owners, manufacturers, distributors, contractors and researchers easily run complex roof and attic simulations. This tool employs modern web technologies, usability design, and national average defaults as an interface to annual simulations of hour-by-hour, whole-building performance using the world-class simulation tools DOE-2.1E and AtticSim in order to provide estimated annual energy and cost savings. In addition to cool reflective roofs, RSC simulates multiple roof and attic configurations including different roof slopes, above sheathing ventilation, radiant barriers, low-emittance roof surfaces, duct location, duct leakage rates, multiple substrate types, and insulation levels. A base case and energy-efficient alternative can be compared side-by-side to estimate monthly energy. RSC was benchmarked against field data from demonstration homes in Ft. Irwin, California; while cooling savings were similar, heating penalty varied significantly across different simulation engines. RSC results reduce cool roofing cost-effectiveness thus mitigating expected economic incentives for this countermeasure to the urban heat island effect. This paper consolidates comparison of RSC s projected energy savings to other simulation engines including DOE-2.1E, AtticSim, Micropas, and EnergyPlus, and presents preliminary analyses. RSC s algorithms for capturing radiant heat transfer and duct interaction in the attic assembly are considered major contributing factors to increased cooling savings and heating penalties. Comparison to previous simulation-based studies, analysis on the force multiplier of RSC cooling savings and heating penalties, the role of radiative heat exchange in an attic assembly, and changes made for increased accuracy of the duct model are included.

  14. Dzialania energooszczedne w rolnictwie (Energy saving measures in agriculture)

    OpenAIRE

    Golaszewski, J; Visser, C.; Stolarski, M.; Brodzinski, Z; Olba-Ziety, E; Myhan, R; Mikkola, H; Ahokas, J.; Jokiniemi, T; Rajaniemi, M; Meyer-Aurich, A.; Ziegler, T.; Briassoulis, D.; Balafoutis, A.; Mistriotis, A.

    2013-01-01

    The reduction of energy inputs in agricultural production is a process of practical implementation of a set of energy saving (ES) measures associated with a given type of production, farm infrastructure and managerial or organizational activities. In six national reports from Finland, Germany, Greece, the Netherlands, Poland and Portugal for 13 subsectors of agriculture, 481 ES measures in total were identified and classified into seven categories: 1) type of energy input: indirect, direct; 2...

  15. Thermal energy test apparatus

    Science.gov (United States)

    Audet, N. F.

    1991-10-01

    The Navy Clothing and Textile Research Facility (NCTRF) designed and fabricated a thermal energy test apparatus to permit evaluation of the heat protection provided by crash crew firefighter's proximity clothing materials against radiant and convective heat loads, similar to those found outside the flame zone of aircraft fuel fires. The apparatus employs electrically operated quartz lamp radiant heaters and a hot air convective heater assembly to produce the heat load conditions the materials to be subjected to, and is equipped with heat flux sensors of different sensitivities to measure the incident heat flux on the sample material as well as the heat flux transmitted by the sample. Tests of the apparatus have shown that it can produce radiant heat flux levels equivalent to those estimated to be possible in close proximity to large aircraft fuel fires, and can produce convective heat fluxes equivalent to those measured in close proximity to aircraft fuel fires at upwind and sidewind locations. Work was performed in 1974.

  16. Future of energy savings policy in Denmark (in Japanese)

    DEFF Research Database (Denmark)

    Nørgaard, Jørgen

    2007-01-01

    After a brief description of Denmark, its energy development and CO2 emission is outlined, especially in the years after 1973. Energy consumption within the country has remained almost constant, but including the country's large merchant fleet, energy consumption has grown by more than 50% to now...... 260 GJ annually per person. Danish energy saving policies with energy taxes, etc. are described. One important measure has been the use of heat from combined heat and power plants to heat buildings, which used to account for 40% of all energy consumption....

  17. Energy saving in housing in Syria; Energieeinsparung im Wohnungsbau in Syrien

    Energy Technology Data Exchange (ETDEWEB)

    Hantouch, Yaser

    2009-06-03

    The demand for energy is increasing in Syria annually by 10-11% and the population increases annually 2.54% This growth leads also to increase in the housing,that it is energy-unconscious and consumes many energy. This large increase in energy consumption is an important problem in the housing in Syria, particularly with the lack of observance of various climatic factors,this leads to install the heating or cooling system in all housing in order to improve thermal comfort. The aim of this work is to provide insights into residential buildings with very high energy efficiency. The starting point is the experience from other countries (such as Germany), which have extensive policies, experience and rules for energy-saving buildings. The aim of this work is to provide insights into residential buildings with very high energy efficiency to win. The starting point is the experience from other countries such as Germany, which has extensive policies and rules for energy-saving buildings have. These are transferred with appropriate additions to residential buildings in Syria, and they are specified for special conditions, as well as the economic, social, climatic and regulatory requirements in Syria. There is a new architectural concepts in the design of residential buildings in Syria on their energy issues to research.it was discussed the links between architecture, energy and ecology, concepts of energy-saving building and influencing factors in energy consumption in buildings analyzed and influence of these factors on building and energy in the study area (Syria). This work includes the calculations of energy-efficient building (temperature and energy consumption) for different variants with different simulation programs, and these are assessed socially and economically through interviews, surveys and calculations of Energy Price and the Cost of Buildings. It turns out that there are many opportunities for energy saving in housing in Syria by architectural, design

  18. Energy Saver: Tips on Saving Energy and Money in Your Home

    Energy Technology Data Exchange (ETDEWEB)

    Casey, Allison L [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-10-04

    This guide shows you how easy it is to reduce your energy use at home and on the road. You'll find quick tips you can use to start saving today, as well as information on larger projects that will help save you money over the long term. Find even more information about saving money and energy at home by visiting our website, EnergySaver.gov.

  19. Electric energy savings from new technologies. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Harrer, B.J.; Kellogg, M.A.; Lyke, A.J.; Imhoff, K.L.; Fisher, Z.J.

    1986-09-01

    Purpose of the report is to provide information about the electricity-saving potential of new technologies to OCEP that it can use in developing alternative long-term projections of US electricity consumption. Low-, base-, and high-case scenarios of the electricity savings for 10 technologies were prepared. The total projected annual savings for the year 2000 for all 10 technologies were 137 billion kilowatt hours (BkWh), 279 BkWh, and 470 BkWh, respectively, for the three cases. The magnitude of these savings projections can be gauged by comparing them to the Department's reference case projection for the 1985 National Energy Policy Plan. In the Department's reference case, total consumption in 2000 is projected to be 3319 BkWh. Because approximately 75% of the base-case estimate of savings are already incorporated into the reference projection, only 25% of the savings estimated here should be subtracted from the reference projection for analysis purposes.

  20. THERMAL ANALYSIS OF THE RESOURCE-SAVING TECHNOLOGY OF FRUIT CHIPS MANUFACTURE

    Directory of Open Access Journals (Sweden)

    G. V. Kalashnikov

    2014-01-01

    Full Text Available Summary. The thermal analysis heat- and mass-exchange of processes has been carried out at heat-moisture of handling of fruits for manufacture of fruit chips. Is suggested resource-saving the technological scheme of a line of processing of fruit and manufactures of fruit chips on the basis of convection and the microwave-drying. The technique is made and results of calculation of thermal expenses for various schemes of manufacture of apple chips are resulted. Thermal expenses for base and offered variants on the basis of balance parities of technological processes and the developed hardware-technological scheme of a line of manufacture of fruit chips with the closed cycle of use of the heat-carrier and the combined convection-microwave-drying of fruit-and-vegetable raw material are certain. Are used recirculation a contour, the heating of the initial raw material fulfilled after drying of pairs and a condensate in the closed contour for creation energy-saving of the "know-how" of a ready product. Comparative thermal efficiency of control surfaces of a line of manufacture of apple chips for the offered technological scheme is shown. Directions of perfection of technological schemes of manufacture of apple chips are certain. Improve the thermal efficiency of the proposed technology facilitates the use of coolant recycling, and the use of heat vapor at various stages of the process, as well as heat exchangers with a capacitor for on-stage heating drained coolant. Useful expenses include heat expended on heating and conversion product. By total losses attributed unused waste heat of coolant, as well as costs due to leaks and mode of working chambers. In order to reduce energy consumption are analyzed and studied heat loss ways to reduce them. It was found that the losses can be reduced through the use of waste after drying coolant heating the dried drying agent and syrup.

  1. Energy saving effects of wireless sensor networks: a case study of convenience stores in Taiwan.

    Science.gov (United States)

    Chen, Chih-Sheng; Lee, Da-Sheng

    2011-01-01

    Wireless sensor network (WSN) technology has been successfully applied to energy saving applications in many places, and plays a significant role in achieving power conservation. However, previous studies do not discuss WSN costs and cost-recovery. The application of WSNs is currently limited to research and laboratory experiments, and not mass industrial production, largely because business owners are unfamiliar with the possible favorable return and cost-recovery on WSN investments. Therefore, this paper focuses on the cost-recovery of WSNs and how to reduce air conditioning energy consumption in convenience stores. The WSN used in this study provides feedback to the gateway and adopts the predicted mean vote (PMV) and computational fluid dynamics (CFD) methods to allow customers to shop in a comfortable yet energy-saving environment. Four convenience stores in Taipei have used the proposed WSN since 2008. In 2008, the experiment was initially designed to optimize air-conditioning for energy saving, but additions to the set-up continued beyond 2008, adding the thermal comfort and crowds peak, off-peak features in 2009 to achieve human-friendly energy savings. Comparison with 2007 data, under the same comfort conditions, shows that the power savings increased by 40% (2008) and 53% (2009), respectively. The cost of the WSN equipment was 500 US dollars. Experimental results, including three years of analysis and calculations, show that the marginal energy conservation benefit of the four convenience stores achieved energy savings of up to 53%, recovering all costs in approximately 5 months. The convenience store group participating in this study was satisfied with the efficiency of energy conservation because of the short cost-recovery period.

  2. Energy-saving methodology for material handling applications

    Energy Technology Data Exchange (ETDEWEB)

    Makris, P.A.; Makri, A.P.; Provatidis, C.G. [National Technical University of Athens, School of Mechanical Engineering, Mechanical Design and Control Systems Division, 9 Iroon Polytechniou Street, Zografou Campus, GR-15773 Athens (Greece)

    2006-10-15

    This paper presents an energy saving approach to the problem of order picking in warehousing environment, which is directly related to the well-known Traveling Salesman Problem (TSP). While the available heuristic algorithms for the order-picking problem search for the route that minimizes the travel time, here the problem is addressed from the energy saving point of view. In a few words, the least energy-consuming route is identified in order to quantify the trade off in time and energy between the fastest route and the most energy economic one. Keeping in mind that often energy is as important as time, especially during a low-demand period, the current paper sheds some light into a two dimensional way of addressing the warehouse material handling problem, which saves time as well as energy. A very interesting finding is that a relatively small loss of service time in many cases may lead to a significant decrease of consumed energy without any additional cost. (author)

  3. Investing EU ETS auction revenues into energy savings

    Energy Technology Data Exchange (ETDEWEB)

    Sijm, J.P.M.; Boonekamp, P.G.M. [ECN Policy Studies, Petten (Netherlands); Summerton, P.; Pollitt, H.; Billington, S. [Cambridge Econometrics CE, Cambridge (United Kingdom)

    2013-05-15

    The overall objective of this study is to analyse the effects of using EU ETS auction revenues to stimulate investments in energy savings in three key target sectors, i.e. Households, Tertiary and Industry (including both ETS and non-ETS industrial installations). The scenarios used refer basically to the situation before the recent agreement on the Energy Efficiency Directive (EED) and include (a mixture of) different policy options to enhance energy savings in the target sectors, in particular (1) reducing the ETS cap, (2) introducing an Energy Efficiency Obligation (EEO) for energy suppliers or distributors, and/or (3) using ETS auction revenues to support additional (private) investments in raising energy efficiency. In order to meet this objective a variety of different policy scenarios have been defined and analysed by means of the 'Energy-Environment-Economy Model for Europe (E3ME)'. The study presents and discusses a large variety of scenario modelling results by the year 2020 at the EU27 level. These results refer to, among others, energy savings, GHG emissions, the ETS carbon price, household electricity bills and to changes in some macro- or socio-economic outcomes such as GDP, inflation, employment or international trade. Finally, the study discusses some policy findings and implications, including options to enhance the effectiveness of some EE policies, in particular those having a potential adverse effect on the ETS carbon price.

  4. Food and drink processing: Introducing energy saving opportunities for business

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-04-15

    The food and drink processing industry is the fourth highest industrial energy user in the UK. In 2000, it consumed nearly 70TWh (enough energy to power one million homes for nearly 15 years) and emitted around 13 million tonnes of carbon dioxide into the atmosphere. Energy consumption in the sector could be considerably reduced by implementing simple and effective energy saving measures, reducing carbon emissions and cutting the costs for businesses. This publication is aimed at managers in the industry working in all sub-sectors. Focusing on the low and no-cost measures and actions which will have the quickest payback, this overview demonstrates the best energy saving opportunities in the sector. The industry is very diverse with many sub-sectors. Each sub-sector employs a range of industrial processes. This guide concentrates on technologies and management techniques that offer the greatest potential for energy saving and that are common to the widest range of sub-sectors. These are: Refrigeration; Process measurement and control; Compressed air; Motors and drives; Boilers and heat distribution; Cooking; Distillation, drying and evaporation; Energy management. The relative importance of each area will also depend on the sub-sector. For example, refrigeration cost will make up a large proportion of energy bills in the frozen and chilled foods sub-sector. Equally, for a business that produces confectionery, boilers and heat distribution systems will make the largest contribution. (GB)

  5. Energy saving by soil insulation in greenhouse freesia production

    NARCIS (Netherlands)

    Helm, van der F.P.M.; Weel, van P.A.; Steenhuizen, J.W.; Zwart, de H.F.; Gelder, de A.

    2014-01-01

    This paper describes attempts to find practical methods for mulching in Freesia to prevent evaporation from the soil. If mulching could insulate soil not only for temperature, but also for evaporation, more energy might be saved. Two experi-ments at commercial greenhouses were done to test soil

  6. Energy Saving Bulbs: An Emerging Threat to Public Health, from ...

    African Journals Online (AJOL)

    DATONYE ALASIA

    SUMMARY. Energy saving bulbs are promoted for their efficiency and capacity to reduce the emission of greenhouse gases, the acknowledged cause of global warming and climate change. They however contain varying quantity of mercury that can easily contaminate the environment. Mercury is a neuro-toxin, but ...

  7. Applicability of energy saving obligations to Indian electricity efficiency efforts

    NARCIS (Netherlands)

    Harmsen, Robert; Moth, Luke; Kumar, Atul

    2014-01-01

    This paper investigates end-use electricity efficiency policies and DSM related aspects within the Indian electricity sector. This work also identifies lessons for India from White Certificate schemes and Energy Saving Obligations in the UK, France and Italy. These two analyses aim to identify

  8. Energy Saving Bulbs: An Emerging Threat to Public Health, from ...

    African Journals Online (AJOL)

    Energy saving bulbs are promoted for their efficiency and capacity to reduce the emission of greenhouse gases, the acknowledged cause of global warming and climate change. They however contain varying quantity of mercury that can easily contaminate the environment. Mercury is a neuro-toxin, but damage has also ...

  9. Potential energy savings by using direct current for residential applications

    DEFF Research Database (Denmark)

    Diaz, Enrique Rodriguez; Quintero, Juan Carlos Vasquez; Guerrero, Josep M.

    2017-01-01

    This paper presents a study of the potential energy savings by implementing dc distribution systems for residential applications. In general, it is commonly accepted that the use of dc voltage improves the efficiency of the distribution, due to a decrease in the conduction losses and an efficienc...

  10. Leveraging Lighting for Energy Savings: GSA Northwest/Artic Region

    Energy Technology Data Exchange (ETDEWEB)

    None

    2016-01-01

    Case study describes how the Northwest/Arctic Region branch of the General Services Administration (GSA) improved safety and energy efficiency in its Fairbanks Federal Building parking garage used by federal employees, U.S. Marshals, and the District Court. A 74% savings was realized by replacing 220 high-pressure sodium fixtures with 220 light-emitting diode fixtures.

  11. A Quantification of the Energy Savings by Conservation Voltage Reduction

    NARCIS (Netherlands)

    Ellens, W.; Berry, A.; West, S.

    2013-01-01

    The introduction of `Smart grid' technologies in the electricity supply industry has attracted new attention to Conservation Voltage Reduction (CVR). CVR is a method that aims to save energy by reducing the voltage level of the electrical distribution network. However, not all devices consume less

  12. 2SaveEnergy-Gewächshaus- Produktion und Energieverbrauch

    NARCIS (Netherlands)

    Kempkes, F.L.K.; Janse, J.

    2016-01-01

    Energy savings through a greenhouse cover of insulation glass requires a large investment. In the search for a cheaper alternative by a consortium of companies consisting of VDH Plastic Greenhouses, Van der Valk Horti Systems, AGC Chemicals Europe en Boal Systems a Glass-Film-greenhouse cover,

  13. Energy Saving Bulbs: An Emerging Threat to Public Health, from ...

    African Journals Online (AJOL)

    DATONYE ALASIA

    Recycling programme should be institutionalized, with the active participation of the manufacturers and importers of the bulbs; while education programme should be mounted on the handling and safe disposal of broken bulbs. Energy Saving Bulbs: An Emerging Threat to Public Health, from. Mercury Contamination of the ...

  14. Energy saving and recovery measures in integrated urban water systems

    Science.gov (United States)

    Freni, Gabriele; Sambito, Mariacrocetta

    2017-11-01

    The present paper describes different energy production, recovery and saving measures which can be applied in an integrated urban water system. Production measures are often based on the installation of photovoltaic systems; the recovery measures are commonly based on hydraulic turbines, exploiting the available pressure potential to produce energy; saving measures are based on substitution of old pumps with higher efficiency ones. The possibility of substituting some of the pipes of the water supply system can be also considered in a recovery scenario in order to reduce leakages and recovery part of the energy needed for water transport and treatment. The reduction of water losses can be obtained through the Active Leakage Control (ALC) strategies resulting in a reduction in energy consumption and in environmental impact. Measures were applied to a real case study to tested it the efficiency, i.e., the integrated urban water system of the Palermo metropolitan area in Sicily (Italy).

  15. EnergySavers: Tips on Saving Money & Energy at Home (Brochure)

    Energy Technology Data Exchange (ETDEWEB)

    2011-12-01

    The U.S. Department of Energy's consumer guide to saving money and energy at home and on the road. It consists of the following articles: (1) Save Money and Energy Today - Get started with things you can do now, and use the whole-house approach to ensure that your investments are wisely made to save you money and energy; (2) Your Home's Energy Use - Find out how your home uses energy, and where it's losing the most energy so you can develop a plan to save in the short and long term; (3) Air Leaks and Insulation - Seal air leaks and insulate your home properly so your energy dollars don't seep through the cracks; (4) Heating and Cooling - Use efficient systems to heat and cool your home, and save money and increase comfort by properly maintaining and upgrading equipment; (5) Water Heating - Use the right water heater for your home, insulate it and lower its temperature, and use less water to avoid paying too much; (6) Windows - Enjoy light and views while saving money by installing energy-efficient windows, and use strategies to keep your current windows from losing energy; (7) Lighting - Choose today's energy-efficient lighting for some of the easiest and cheapest ways to reduce your electric bill; (8) Appliances - Use efficient appliances through-out your home, and get greater performance with lower energy bills; (9) Home Office and Electronics - Find out how much energy your electronics use, reduce their out-put when you're not using them, and choose efficient electronics to save money; (10) Renewable Energy - Use renewable energy at home such as solar and wind to save energy dollars while reducing environmental impact; (11) Transportation - Choose efficient transportation options and drive more efficiently to save at the gas pump; and (12) References - Use our reference list to learn more about energy efficiency and renewable energy.

  16. Decentralized energy-saving hydraulic concepts for mobile working machines

    OpenAIRE

    Lodewyks, Johann; Zurbrügg, Pascal

    2016-01-01

    The high price of batteries in working machines with electric drives offer a potential for investment in energy-saving hydraulic systems. The decentralized power network opens up new approaches for hydraulic- and hybrid circuits. In addition, the regeneration of energy can be used at any point of the machine. For the example of an excavator arm drive with a double cylinder two compact hydraulic circuits are presented, which relieve a central hydraulic system.

  17. Wooden facade decor in the aspect of energy saving

    Directory of Open Access Journals (Sweden)

    Samol'kina Elena Grigor'evna

    2014-09-01

    Full Text Available In the world of today, issues of the relationship between society and nature are becoming more relevant. A process of continuous development of industrial and social activities and the negative interference in the environment cause damage to the unique biosphere. The dynamics of destructive processes necessitates conducting activities in accordance with the fundamental laws of nature. One way of solving these problems is to create a harmonious architectural environment that has minimal impact on the environment of the surrounding countryside. An important factor in the process of "sustainable architecture" formation is the use of the building materials, which are safe for humans and the environment. Special role in this aspect is played by wood possessing unquestionable priority in "sustainable architecture". Wood is a renewable natural material with unique properties. Wastelessness, low thermal conductivity, strength, unique texture, ease of processing and other quality wood help to create cozy and comfortable environment. From the perspective of ecological and energy problems the use of wood in architecture has a special role as the most optimal solution to these issues. In Russia construction of energy efficient buildings is at an early stage of development. To date, the power consumption of the existing residential and public buildings in Russia is on average about three times higher than in technically advanced countries of Scandinavia with similar climatic conditions. At the same time the tendency to steady growth of non-renewable energy resources leads to the need to improve the thermal protection of buildings. The problem of thermal protection of buildings in architecture led to widespread use of ventilated facades. Constructive solution is to install the layer of insulation on the exterior walls and to fasten cladding materials to the frame to form an air gap for air circulation. Finishing materials perform architectural function. The

  18. Energy Saving by Chopping off Peak Demand Using Day Light

    Directory of Open Access Journals (Sweden)

    Ashok Kumar Maitra

    2011-08-01

    Full Text Available An artificial intelligent technique has been implemented in this research using real time datas to calculate how much energy can be chopped from peak load demand. The results are based on real time data that are taken from power delivering centers. These datas do reflect the present condition of power and a solution to those critical conditions during the peak period. These are done in such a way such that helps in judicious scheduling of load. The time based load scheduling has been done so as to understand the basic criteria for solving power crisis during morning peak and early evening peak. The sunray availability and percentage of load that will use day light saving (DLS technique has been taken into account in this work. The results shows that about 0.5% to 1% of load can be shedded off from the peak load period which otherwise is reduction of power. Thus it otherwise also means that an equivalent amount of energy is saved which amounts to a large saving of national money. This result is obtained on monthly and even daily basis. Thus this paper justifies DLS gives a new renewable technique to save energy.

  19. Portable+: A Ubiquitous And Smart Way Towards Comfortable Energy Savings

    Energy Technology Data Exchange (ETDEWEB)

    Jain, Milan [IIIT-Delhi; Singh, Amarjeet [IIIT-Delhi; Chandan, Vikas [Pacific Northwest National Laboratory

    2017-06-30

    An air conditioner (AC) consumes a significant proportion of the total household power consumption. Primarily used in developing countries, decentralised AC has an inbuilt thermostat to cool the room to a temperature, manually set by the users. However, residents are incapable of specifying their goal through these thermostats - maximise their comfort or save AC energy. State-of-the-art portable thermostats emulate AC remotes and assist occupants in remotely changing the thermostat temperature, through their smartphones. We propose extending such thermostats to portable+ by adding a Comfort-Energy Trade-off (CET) knob, realised through an optimisation framework to allow users to balance their comfort and the savings without worrying about the right set temperature. Analysis based on real data, collected from a controlled experiment (across two rooms for two weeks) and an in-situ deployment (across five rooms for three months), indicates that portable+ thermostats can reduce residents’ discomfort by 23% (CET selection for maximal comfort) and save 26% energy when CET is set for maximising savings.

  20. Heat Saving Strategies in Sustainable Smart Energy Systems

    DEFF Research Database (Denmark)

    Lund, Henrik; Thellufsen, Jakob Zinck; Aggerholm, Søren

    2014-01-01

    This paper investigates to which extent heat should be saved rather than produced and to which extent district heating infrastructures, rather than individual heating solutions, should be used in future sustainable smart energy systems. Based on a concrete proposal to implement the Danish...... governmental 2050 fossil-free vision, this paper identifies marginal heat production costs and compares these to marginal heat savings costs for two different levels of district heating. A suitable least-cost heating strategy seems to be to invest in an approximately 50% decrease in net heat demands in new...... buildings and buildings that are being renovated anyway, while the implementation of heat savings in buildings that are not being renovated hardly pays. Moreover, the analysis points in the direction that a least-cost strategy will be to provide approximately 2/3 of the heat demand from district heating...

  1. Heat Saving Strategies in Sustainable Smart Energy Systems

    Directory of Open Access Journals (Sweden)

    Henrik Lund

    2014-06-01

    Full Text Available This paper investigates to which extent heat should be saved rather than produced and to which extent district heating infrastructures, rather than individual heating solutions, should be used in future sustainable smart energy systems. Based on a concrete proposal to implement the Danish governmental 2050 fossil-free vision, this paper identifies marginal heat production costs and compares these to marginal heat savings costs for two different levels of district heating. A suitable least-cost heating strategy seems to be to invest in an approximately 50% decrease in net heat demands in new buildings and buildings that are being renovated anyway, while the implementation of heat savings in buildings that are not being renovated hardly pays. Moreover, the analysis points in the direction that a least-cost strategy will be to provide approximately 2/3 of the heat demand from district heating and the rest from individual heat pumps.

  2. Analysis of energy-saving dispatch based on energy efficiency for power system with large scale wind power integration

    Science.gov (United States)

    Zou, Lanqing; Zhou, Peng; Li, Shitong; Lin, Li

    2017-01-01

    With the increasing of wind generators and the scale of wind farm, the utilization rate of wind power decreases continually, it is essential to develop an energy-saving dispatching model for the purpose of energy conservation and emission reduction. Firstly, considering some main factors, such as generator operating costs, start-up unit costs, shutdown unit costs, oil consumption and pollutant emission, establish an energy efficiency model. Then, based on the principle of energy-saving dispatch, a model is established which objective is maximizing the energy efficiency. Moreover, in order to realize the priority dispatching of wind power, another model is established which objective is minimizing the wind power shedding. Finally, under the conditions of different installed wind power capacities being integrated into a real region grid, two models are compared and analyzed from perspectives of the society, thermal power enterprise and wind power enterprise.

  3. Ice rinks skate to energy savings, light quality

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1997-11-01

    Retrofitting community ice arenas with modern fluorescent lighting systems in place of the traditional high intensity discharge (HID) metal halide, high pressure sodium or mercury vapour systems to achieve significant energy savings, was discussed. Using the one-two-three-lamp version of a `Triad` instant start, RH series electronic ballasts (manufactured by MagneTek of Nashville, Tennessee) and the right combination of housing, energy consumption at full lighting levels has dropped to 45 to 50 per cent of the previous HID system. The new system also provides a wide range of light levels, and since full illumination is needed only occasionally the actual energy savings are in the 75 to 80 per cent range.

  4. Energy savings in mobile broadband network based on load predictions

    DEFF Research Database (Denmark)

    Samulevicius, Saulius; Pedersen, Torben Bach; Sørensen, Troels Bundgaard

    2012-01-01

    in wireless networks. To save energy in MBNs, one of the options is to turn off parts of the network equipment in areas where traffic falls below a specific predefined threshold. This paper looks at a methodology for identifying periods of the day when cells or sites carrying low traffic are candidates...... for being totally or partly switched off, given that the decrease in service quality can be controlled gracefully when the sites are switched off. Based on traffic data from an operational network, potential average energy savings of approximately 30% with some few low traffic cells/sites reaching up to 99......Abstract—The deployment of new network equipment is resulting in increasing energy consumption in mobile broadband networks (MBNs). This contributes to higher CO2 emissions. Over the last 10 years MBNs have grown considerably, and are still growing to meet the evolution in traffic volume carried...

  5. Energy saving lamps; Les lampes a economie d'energie

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-12-01

    Energy saving lamps correspond to folded fluorescent tubes with a bulb-shape. This brochure presents all technical aspects of energy saving lamps: lighting efficiency and lifetime, available models, advantages and quality labelling, collection and processing of used lamps, quality criteria, costs and performances. (J.S.)

  6. Energy saving potential of emerging technologies in milk powder production

    NARCIS (Netherlands)

    Moejes, S.N.; Boxtel, van A.J.B.

    2017-01-01

    Background: The food industry has a large potential for energy reduction which, with an eye on the future, has to be exploited. Milk powder production consists of many thermal processes and is responsible for 15% of the total energy use in the dairy industry. A reduction in energy consumption can be

  7. Green Energy in New Construction: Maximize Energy Savings and Minimize Cost

    Science.gov (United States)

    Ventresca, Joseph

    2010-01-01

    People often use the term "green energy" to refer to alternative energy technologies. But green energy doesn't guarantee maximum energy savings at a minimum cost--a common misconception. For school business officials, green energy means getting the lowest energy bills for the lowest construction cost, which translates into maximizing green energy…

  8. An Investigation on the Energy Saving Potential of Electromagnetic Ballast Fluorescent Lamps

    Science.gov (United States)

    Cheong, Z. X.; Barsoum, N. N.

    2009-08-01

    Energy saving issue is a matter of great concern for industry and electrical utilities. Energy saving from fluorescent lamp system can be achieved by means of optimizing lighting level, reducing power consumption and improving the efficiency of fluorescent lamps. This paper presents an alternative energy saving control method for electromagnetic ballast fluorescent lamps. Non-linearity characteristics of fluorescent lamps and the effect of energy saving controller are taken into account in the proposed energy saving controller. The proposed energy saving controller provides energy saving feature and dimmable illuminance level control for electromagnetic ballast fluorescent lamps. In comparison to electronic ballast, integration of an energy saving controller with electromagnetic ballast results in less power consumption, less green house gas emission and longer lifespan at a much lower installation cost. Experiment results based on the proposed controller showed that 37.5% energy can be saved by reducing 15% of the AC line voltage.

  9. Maximizing Residential Energy Savings: Net Zero Energy House (ZEH) Technology Pathways

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, R.; Roberts, D.

    2008-11-01

    To meet current U.S. Department of Energy zero-energy home performance goals, new technologies and solutions must increase whole-house efficiency savings by an additional 40% relative to those provided by best available components and systems.

  10. Energy demand hourly simulations and energy saving strategies in greenhouses for the Mediterranean climate

    Science.gov (United States)

    Priarone, A.; Fossa, M.; Paietta, E.; Rolando, D.

    2017-01-01

    This research has been devoted to the selection of the most favourable plant solutions for ventilation, heating and cooling, thermo-hygrometric control of a greenhouse, in the framework of the energy saving and the environmental protection. The identified plant solutions include shading of glazing surfaces, natural ventilation by means of controlled opening windows, forced convection of external air and forced convection of air treated by the HVAC system for both heating and cooling. The selected solution combines HVAC system to a Ground Coupled Heat Pump (GCHP), which is an innovative renewable technology applied to greenhouse buildings. The energy demand and thermal loads of the greenhouse to fulfil the requested internal design conditions have been evaluated through an hourly numerical simulation, using the Energy Plus (E-plus) software. The overall heat balance of the greenhouse also includes the latent heat exchange due to crop evapotranspiration, accounted through an original iterative calculation procedure that combines the E-plus dynamic simulations and the FAO Penman-Monteith method. The obtained hourly thermal loads have been used to size the borehole field for the geothermal heat pump by using a dedicated GCHP hourly simulation tool.

  11. Energy-saving wastewater treatment systems: formulation of cost functions.

    Science.gov (United States)

    Nogueira, R; Ferreira, I; Janknecht, P; Rodríguez, J J; Oliveira, P; Brito, A G

    2007-01-01

    Natural interactions between water, soil, atmosphere, plants and microorganisms include physical, chemical and biological processes with decontaminating capacities. Natural or energy-saving wastewater treatment systems utilize these processes and thereby enable a sustainable management in the field of wastewater treatment, offering low investment and operation costs, little or no energy consumption, little and low-skill labor requirements, good landscape integration and excellent feasibility for small settlements, especially when remote from centralized sewer systems. The objective of this work is the development of cost functions for investment and operation of energy-saving wastewater treatment technologies. Cost functions are essential for making cost estimations based on a very reduced number of variables. The latter are easily identified and quantified and have a direct bearing on the costs in question. The formulated investment and operation cost functions follow a power law, and the costs decrease with the increase of the population served. The different energy-saving wastewater treatment systems serving small population settlements, between 50 p.e. and 250 p.e., present associated investment costs varying from 400 Euro/p.e. to 200 Euro/p.e. and annual operation costs in the range of 70 Euro/p.e. to 20 Euro/p.e., respectively.

  12. Potential Energy Savings in Refrigeration Systems Using Optimal Setpoints

    DEFF Research Database (Denmark)

    Larsen, Lars Finn Slot; Thybo, Claus

    2004-01-01

    Energy efficiency of refrigeration systems has gradually been improved with help of control schemes utilizing the more flexible components. This paper proposes an approach in line with this trend, where a suboptimal condenser pressure is found in order to minimize the energy consumption....... The objective is to give an idea of how this optimization scheme works as well as to show what amount of energy it is possible to save. A steady state model of a simple refrigeration system will be used as a basis for the optimization....

  13. Thermal energy at the nanoscale

    CERN Document Server

    Fisher, Timothy S

    2014-01-01

    These lecture notes provide a detailed treatment of the thermal energy storage and transport by conduction in natural and fabricated structures. Thermal energy in two carriers, i.e. phonons and electrons -- are explored from first principles. For solid-state transport, a common Landauer framework is used for heat flow. Issues including the quantum of thermal conductance, ballistic interface resistance, and carrier scattering are elucidated. Bulk material properties, such as thermal and electrical conductivity, are derived from particle transport theories, and the effects of spatial confinement on these properties are established. Readership: Students and professionals in physics and engineering.

  14. Chapter 21: Estimating Net Savings - Common Practices. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    Energy Technology Data Exchange (ETDEWEB)

    Kurnik, Charles W [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Violette, Daniel M. [Navigant, Boulder, CO (United States); Rathbun, Pamela [Tetra Tech, Madison, WI (United States)

    2017-11-02

    This chapter focuses on the methods used to estimate net energy savings in evaluation, measurement, and verification (EM and V) studies for energy efficiency (EE) programs. The chapter provides a definition of net savings, which remains an unsettled topic both within the EE evaluation community and across the broader public policy evaluation community, particularly in the context of attribution of savings to a program. The chapter differs from the measure-specific Uniform Methods Project (UMP) chapters in both its approach and work product. Unlike other UMP resources that provide recommended protocols for determining gross energy savings, this chapter describes and compares the current industry practices for determining net energy savings but does not prescribe methods.

  15. Fossil energy savings potential of sugar cane bio-energy systems

    DEFF Research Database (Denmark)

    Nguyen, Thu Lan T; Hermansen, John Erik; Sagisaka, Masayuki

    2009-01-01

    One important rationale for bio-energy systems is their potential to save fossil energy. Converting a conventional sugar mill into a bio-energy process plant would contribute to fossil energy savings via the extraction of renewable electricity and ethanol substituting for fossil electricity...... and gasoline, respectively. This paper takes a closer look at the Thai sugar industry and examines two practical approaches that will enhance fossil energy savings. The first one addresses an efficient extraction of energy in the form of electricity from the excess bagasse and cane trash. The second while...... proposing to convert molasses or sugar cane to ethanol stresses the use of bagasse as well as distillery spent wash to replace coal in meeting ethanol plants' energy needs. The savings potential achieved with extracting ethanol from surplus sugar versus current practice in sugar industry in Thailand amounts...

  16. Computer simulation for optimizing windbreak placement to save energy for heating and cooling buildings

    Science.gov (United States)

    Gordon M. Heisler

    1991-01-01

    Saving energy has recently acquired new importance because of increased concern for dwindling fossil fuel supplies and for the problem of carbon dioxide contributions to global climate change. Many studies have indicated that windbreaks have the ability to save energy for heating buildings. Suggested savings have ranged up 40 percent; though more commonly savings of...

  17. Ocean Thermal Extractable Energy Visualization

    Energy Technology Data Exchange (ETDEWEB)

    Ascari, Matthew [Lockheed Martin Corporation, Bethesda, MD (United States)

    2012-10-28

    The Ocean Thermal Extractable Energy Visualization (OTEEV) project focuses on assessing the Maximum Practicably Extractable Energy (MPEE) from the world’s ocean thermal resources. MPEE is defined as being sustainable and technically feasible, given today’s state-of-the-art ocean energy technology. Under this project the OTEEV team developed a comprehensive Geospatial Information System (GIS) dataset and software tool, and used the tool to provide a meaningful assessment of MPEE from the global and domestic U.S. ocean thermal resources.

  18. Aquifer thermal energy storage. International symposium: Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-05-01

    Aquifers have been used to store large quantities of thermal energy to supply process cooling, space cooling, space heating, and ventilation air preheating, and can be used with or without heat pumps. Aquifers are used as energy sinks and sources when supply and demand for energy do not coincide. Aquifer thermal energy storage may be used on a short-term or long-term basis; as the sole source of energy or as a partial storage; at a temperature useful for direct application or needing upgrade. The sources of energy used for aquifer storage are ambient air, usually cold winter air; waste or by-product energy; and renewable energy such as solar. The present technical, financial and environmental status of ATES is promising. Numerous projects are operating and under development in several countries. These projects are listed and results from Canada and elsewhere are used to illustrate the present status of ATES. Technical obstacles have been addressed and have largely been overcome. Cold storage in aquifers can be seen as a standard design option in the near future as it presently is in some countries. The cost-effectiveness of aquifer thermal energy storage is based on the capital cost avoidance of conventional chilling equipment and energy savings. ATES is one of many developments in energy efficient building technology and its success depends on relating it to important building market and environmental trends. This paper attempts to provide guidance for the future implementation of ATES. Individual projects have been processed separately for entry onto the Department of Energy databases.

  19. ASSESSMENT OF ENERGY SAVING IN WASTE RECYCLING USING SYSTEM DYNAMICS

    Directory of Open Access Journals (Sweden)

    Eugênio de Oliveira Simonetto

    2013-06-01

    Full Text Available Recycling is a topic of great importance in integrated waste management, evidence of this is verified in the National Policy of Solid Waste, decreed in 2010, where it is considered one of the priorities. In this article is presented a computer simulation model, since their development until its validation, which aims to support environmental managers in their decisions regarding the definition and / or maintenance of solid waste policies recycling, as well as evaluating the benefits of process in the environment (in this article we evaluated the energy savings. For the model development was considered: the rate of natural population growth (births and deaths, percentage of solid waste recycled (for each type of material, gravimetric composition of the material in the total waste generated, the amount of waste generated per inhabitant and energy savings caused by each distinct type of material. Through the model results generated, end users (environmental managers thereof may, for example, set incentives to reduce the total generation of solid waste, produce campaigns enhancing reuse and recycling and to assess the relative benefits of energy savings caused by recycling. Model validation was through analysis of future scenarios for a given municipality in southern Brazil. For modeling and system validation was used Vensim from Ventana Systems.

  20. Energy, Carbon-emission and Financial Savings from Thermostat Control

    Energy Technology Data Exchange (ETDEWEB)

    Blasing, T J [ORNL; Schroeder, Dana [University of Georgia, Athens, GA

    2013-08-01

    Among the easiest approaches to energy, and cost, savings for most people is the adjustment of thermostats to save energy. Here we estimate savings of energy, carbon, and money in the United States of America (USA) that would result from adjusting thermostats in residential and commercial buildings by about half a degree Celsius downward during the heating season and upward during the cooling season. To obtain as small a unit as possible, and therefore the least likely to be noticeable by most people, we selected an adjustment of one degree Fahrenheit (0.56 degree Celsius) which is the gradation used almost exclusively on thermostats in the USA and is the smallest unit of temperature that has been used historically. Heating and/or cooling of interior building space for personal comfort is sometimes referred to as space conditioning, a term we will use for convenience throughout this work without consideration of humidity. Thermostat adjustment, as we use the term here, applies to thermostats that control the indoor temperature, and not to other thermostats such as those on water heaters. We track emissions of carbon only, rather than of carbon dioxide, because carbon atoms change atomic partners as they move through the carbon cycle, from atmosphere to biosphere or ocean and, on longer time scales, through the rock cycle. To convert a mass of carbon to an equivalent mass of carbon dioxide (thereby including the mass of the 2 oxygen atoms in each molecule) simply multiply by 3.67.

  1. Thermal dynamic simulation of wall for building energy efficiency under varied climate environment

    Science.gov (United States)

    Wang, Xuejin; Zhang, Yujin; Hong, Jing

    2017-08-01

    Aiming at different kind of walls in five cities of different zoning for thermal design, using thermal instantaneous response factors method, the author develops software to calculation air conditioning cooling load temperature, thermal response factors, and periodic response factors. On the basis of the data, the author gives the net work analysis about the influence of dynamic thermal of wall on air-conditioning load and thermal environment in building of different zoning for thermal design regional, and put forward the strategy how to design thermal insulation and heat preservation wall base on dynamic thermal characteristic of wall under different zoning for thermal design regional. And then provide the theory basis and the technical references for the further study on the heat preservation with the insulation are in the service of energy saving wall design. All-year thermal dynamic load simulating and energy consumption analysis for new energy-saving building is very important in building environment. This software will provide the referable scientific foundation for all-year new thermal dynamic load simulation, energy consumption analysis, building environment systems control, carrying through farther research on thermal particularity and general particularity evaluation for new energy -saving walls building. Based on which, we will not only expediently design system of building energy, but also analyze building energy consumption and carry through scientific energy management. The study will provide the referable scientific foundation for carrying through farther research on thermal particularity and general particularity evaluation for new energy saving walls building.

  2. Improving Energy Saving Techniques by Ambient Intelligence Scheduling

    DEFF Research Database (Denmark)

    Cristani, Matteo; Karafili, Erisa; Tomazzoli, Claudio

    2015-01-01

    Energy saving is one of the most challenging aspects of modern ambient intelligence technologies, for both domestic and business usages. In this paper we show how to combine Ambient Intelligence and Artificial Intelligence techniques to solve the problem of scheduling a set of devices under a given...... set of constraints, like limits to the maximal energy usage (Energy Span) and maximal energy absorption (Energy Peak). We provide a method that can be used to schedule the usage of devices in a given environment in a way that respects the input constraints. We adapt an existent approach to scheduling...... for Ambient Intelligence to a specific framework and exhibit a sample usage for a real life system, Elettra, that is in use in an industrial context....

  3. Triangular Energy-Saving Cache-Based Routing Protocol by Energy Sieving

    OpenAIRE

    Chiu-Ching Tuan; Yi-Chao Wu

    2012-01-01

    In wireless ad hoc networks, designing an energy-efficient routing protocol is a major issue since nodes are energy limited. To address energy issue, we proposed a triangular energy-saving cached-based routing protocol by energy sieving (TESCES). TESCES offered a grid leader election by energy sieving (GLEES), a cache-based grid leader maintenance (CGLM), and a triangular energy-saving routing discovery (TESRD). In GLEES, only few nodes join in grid leader election to be elected as a grid lea...

  4. Energy Savings Opportunities and Energy Efficiency Performance Indicators for a Serial Production Line

    OpenAIRE

    Brundage, Michael; Chang, Qing; Wang, Shiyao; Feng, Shaw; Xiao, Guoxian; Arinez, Jorge

    2013-01-01

    Part 2: Sustainable Supply Chains; International audience; Modern manufacturing facilities waste various energy savings opportunities (ESO) and lack proper performance indicators to measure energy efficiency on the production line. The ESO is an opportunity window calculated from on-line production data, such as production count, machine downtime records, buffer levels, and machine idle status, allowing certain machines to be turned off for energy savings without negatively affecting throughp...

  5. Compressed air systems. A guidebook on energy and cost savings

    Energy Technology Data Exchange (ETDEWEB)

    1984-03-30

    This guidebook shows how energy can be saved in compressed air systems. It discusses basic compressed air systems which are typical of those found in industry and describes them and the engineering practices behind them. Energy conservation recommendations follow. These recommendations cover equipment selection, design, maintenance, and operation. Included is information which will help the reader to make economic evaluations of various engineering and equipment alternatives as they affect operations and costs. The appendices include some modern computer based approaches to predicting pressure drop for designing compressed air distribution systems. Also included is a bibliography providing leads for further and more detailed technical information on these and related subjects.

  6. Passive Collecting of Solar Radiation Energy using Transparent Thermal Insulators, Energetic Efficiency of Transparent Thermal Insulators

    Directory of Open Access Journals (Sweden)

    Smajo Sulejmanovic

    2014-11-01

    Full Text Available This paper explains passive collection of solar radiation energy using transparent thermal insulators. Transparent thermal insulators are transparent for sunlight, at the same time those are very good thermal insulators. Transparent thermal insulators can be placed instead of standard conventional thermal insulators and additionally transparent insulators can capture solar radiation, transform it into heat and save heat just as standard insulators. Using transparent insulators would lead to reduce in usage of fossil fuels and would help protection of an environment and reduce effects of global warming, etc.

  7. Saving energy through improved combustion; Energiesparen durch bessere Verbrennung

    Energy Technology Data Exchange (ETDEWEB)

    Stadelmann, M.

    2010-07-01

    This short article discusses how controlling oxygen supply can reduce residual oxygen in the flue gases of the burners of heating systems. The author discusses how the necessary amount of excess oxygen fed into the burner's flame can be controlled and thus minimised. In this way, the efficiency of the heating system can be improved and, as a result, energy can be saved. Also, the various factors influencing the amount of excess oxygen to be provided are discussed and typical figures for various types of burners, e.g. wood, oil, natural gas, are quoted. The control of the speed of the ventilators in the burners is also looked at. Savings in CO{sub 2} emissions and the pay-back for the oxygen control system are also discussed.

  8. Energy-saving building construction in Leipzig; Energiesparendes Bauen in Leipzig

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2010-07-01

    Construction of a new building or modernization of an older one is a great challenge. Complex decisions must be made, with long-term effects. This brochure presents practical information on modernization and energy conservation, thermal insulation, funding options, smart houses and barrier-free bathrooms, as well as modern heating systems. Subjects: List of suppliers; Modernization and energy conservation for environment-friendly and cost-saving buildings, Successful modernization; Lifts; Heating systems; SmartHouses; Modern ventilation systems for higher room air quality; Barrier-free bathrooms; An exemplary modernization project; Funding programmes. (orig.)

  9. Lighting Energy Saving with Light Pipe in Farm Animal Production

    Directory of Open Access Journals (Sweden)

    Hans von Wachenfelt

    2015-12-01

    Full Text Available The Swedish animal production sector has potential for saving electric lighting of €4-9 million per year using efficient daylight utilisation. To demonstrate this, two light pipe systems, Velux® (house 1 and Solatube® (house 2, are installed in two identical pig houses to determine if the required light intensity, daylight autonomy (DA, and reduced electricity use for illumination can be achieved. In each house, three light sensors continuously measure the indoor daylight relative to an outdoor sensor. If the horizontal illuminance at pig height decreases below 40 lux between 08.00 and 16.00 hours, an automatic control system activates the lights, and electricity use is measured. The daylight factor (DF and DA are determined for each house, based on annual climate data. The mean annual DA of 48% and 55% is achieved for house 1 and house 2, respectively. Light pipes in house 2 have delivered significantly more DA than those in house 1. The most common illuminance range between 0 and 160 lux is recorded in both houses, corresponding to approximately 82% and 83% of daylight time for house 1 and house 2, respectively. Further, the daylighting system for house 2 has produced a uniform DF distribution between 0.05 and 0.59. The results demonstrate that considerable electric energy savings can be achieved in the animal production sector using light pipes. Saving 50% of electric lighting would correspond to 36 GWh or 2520 t CO2 per year for Sweden, but currently the energy savings are not making the investment profitable.

  10. The unrecognized contribution of renewable energy to Europe's energy savings target

    NARCIS (Netherlands)

    Harmsen, R.; Wesselink, B.; Eichhammer, W.; Worrell, E.

    2011-01-01

    We show that renewable energy contributes to Europe's 2020 primary energy savings target. This contribution, which is to a large extent still unknown and not recognized by policy makers, results from the way renewable energy is dealt with in Europe's energy statistics. We discuss the policy

  11. Individual energy savings for individual flats in blocks of flats

    DEFF Research Database (Denmark)

    Nielsen, Anker; Rose, Jørgen

    2014-01-01

    is distributed on the individual flats. Today, most blocks of flats have individual heat meters to save energy and to ensure a fair distribution of the cost. If all flats have the same indoor temperature, the distribution is correct. In practice, the inhabitants of the different flats maintain different indoor......It is well known that similar flats in a block do not have the same energy demand. Part of the explanation for this is the location of the flat in the building, e.g. on the top floor, at the house end or in the middle of the building. It is possible to take this into account when the heating bill...... temperatures. The result is that heat flows between individual flats. This decreases the energy consumption in the flat where the owner maintains a lower temperature. The neighbouring flats will have higher energy consumption. Calculations were performed for Danish blocks of flats from 1920, 1940, 1960...

  12. Energy Saving: Scaling Network Energy Efficiency Faster than Traffic Growth

    NARCIS (Netherlands)

    Chen, Y.; Blume, O.; Gati, A.; Capone, A.; Wu, C.E.; Barth, U.; Marzetta, T.; Zhang, H.; Xu, S.

    2013-01-01

    As the mobile traffic is expected to continue its exponential growth in the near future, energy efficiency has gradually become a must criterion for wireless network design. Three fundamental questions need to be answered before the detailed design could be carried out, namely what energy efficiency

  13. Actual and Estimated Energy Savings Comparison for Deep Energy Retrofits in the Pacific Northwest

    Energy Technology Data Exchange (ETDEWEB)

    Blanchard, Jeremy; Widder, Sarah H.; Giever, Elisabeth L.; Baechler, Michael C.

    2012-10-01

    Seven homes from the Pacific Northwest were selected to evaluate the differences between estimated and actual energy savings achieved from deep energy retrofits. The energy savings resulting from these retrofits were estimated, using energy modeling software, to save at least 30% on a whole-house basis. The modeled pre-retrofit energy use was trued against monthly utility bills. After the retrofits were completed, each of the homes was extensively monitored, with the exception of one home which was monitored pre-retrofit. This work is being conducted by Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy Building Technologies Program as part of the Building America Program. This work found many discrepancies between actual and estimated energy savings and identified the potential causes for the discrepancies. The differences between actual energy use and modeled energy use also suggest improvements to improve model accuracy. The difference between monthly whole-house actual and estimated energy savings ranged from 75% more energy saved than predicted by the model to 16% less energy saved for all the monitored homes. Similarly, the annual energy savings difference was between 36% and -14%, which was estimated based on existing monitored savings because an entire year of data is not available. Thus, on average, for all six monitored homes the actual energy use is consistently less than estimates, indicating home owners are saving more energy than estimated. The average estimated savings for the eight month monitoring period is 43%, compared to an estimated savings average of 31%. Though this average difference is only 12%, the range of inaccuracies found for specific end-uses is far greater and are the values used to directly estimate energy savings from specific retrofits. Specifically, the monthly post-retrofit energy use differences for specific end-uses (i.e., heating, cooling, hot water, appliances, etc.) ranged from 131% under

  14. Energy saving technologies of the decentralized ventilation of buildings

    Science.gov (United States)

    Mansurov, R. Sh; Rafalskaya, T. A.

    2017-11-01

    The growing aspiration to energy saving and efficiency of energy leads to necessity to build tight enough buildings. As a result of this the quantity of infiltration air appears insufficient for realization of necessary air exchange in. One of decisions of the given problem is development and application for ventilation of premises of the decentralized forced-air and exhaust systems (DFAES) with recuperative or regenerative heat-exchangers. For an estimation of efficiency of DFAES following basic parameters have been certain: factor of energy saving; factor of efficiency of energy; factor of a heat transfer; factor of an effective utilization of a surface of heat exchange. Were estimated temperature of forced air; actual speed of an air jet on an entrance in a served zone; actual noise level; the charge of external air. Tests of DFAES were spent in natural conditions at which DFAES influenced all set of factors both an external climate, and an internal microclimate of a premise, and also the arrangement on a wind side or behind wind side of a building, influence of surrounding building, fluctuation of temperature of external air is considered. Proceeding from results and the analysis of the lead researches recommendations have been developed for development and manufacture of new sample of DFAES.

  15. The impact of translucent fabric shades and control strategies on energy savings and visual quality

    Science.gov (United States)

    Wankanapon, Pimonmart

    Translucent fabric shades provide opportunities for building occupants to control sunlight penetration for heat reduction, thermal comfort, and visual quality. Regulating shades affects building energy and can potentially reduce the size of mechanical cooling systems. Shades are not normally included in energy model studies during the design process, even though shades potential impact energy use. This is because the occupants normally leave shades closed a large fraction of the time, but models are generally performed with no shades. Automatic shade control is now available, so it is necessary to understand the impact of shades on visual quality and their energy saving potential in order to optimize their overall performance. There are very limited studies that have address shades and their integrated performance on energy consumption and visual quality. Most of these do not reflected modern shade types and their application. The goals of this study are: First, to determine the impact of shades on total, heating, cooling and lighting energy savings with different design and operation parameters. Second, to study and develop different automatic shade control strategies to promote and optimize energy savings and visual quality. A simulation-based approach using EnergyPlus in a parametric study provide better understanding energy savings under different shade conditions. The parametric runs addressed various building parameters such as geometry, orientation, site climate, glazing/shade properties, and shade control strategies with integrated lighting control. The impact of shades was determined for total building and space heating, cooling and lighting energy savings. The effect of shades on visual quality was studied using EnergyPlus, AGI32 and DAYSIM for several indices such as daylight glare index (DGI), work plane illuminance, luminance ratios and view. Different shade control strategies and integrated lighting control were considered with two translucent fabric

  16. Bandwidth Study on Energy Use and Potential Energy Saving Opportunities in U.S. Pulp and Paper Manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    Sabine Brueske, Caroline Kramer, Aaron Fisher

    2015-06-01

    Energy bandwidth studies of U.S. manufacturing sectors can serve as foundational references in framing the range (or bandwidth) of potential energy savings opportunities. This bandwidth study examines energy consumption and potential energy savings opportunities in U.S. pulp and paper manufacturing. The study relies on multiple sources to estimate the energy used in six individual process areas, representing 52% of sector-wide energy consumption. Energy savings opportunities for individual processes are based on technologies currently in use or under development; the potential savings are then extrapolated to estimate sector-wide energy savings opportunity

  17. Bandwidth Study on Energy Use and Potential Energy Saving Opportunities in U.S. Iron and Steel Manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    Keith Jamison, Caroline Kramer, Sabine Brueske, Aaron Fisher

    2015-06-01

    Energy bandwidth studies of U.S. manufacturing sectors can serve as foundational references in framing the range (or bandwidth) of potential energy savings opportunities. This bandwidth study examines energy consumption and potential energy savings opportunities in U.S. iron and steel manufacturing. The study relies on multiple sources to estimate the energy used in six individual process areas and select subareas, representing 82% of sector-wide energy consumption. Energy savings opportunities for individual processes and subareas are based on technologies currently in use or under development; the potential savings are then extrapolated to estimate sector-wide energy savings opportunity.

  18. The effect of architectural façade design on energy savings in the student dormitory

    Directory of Open Access Journals (Sweden)

    Pejić Petar Č.

    2014-01-01

    Full Text Available There are many reasons for adequate use of natural light inside students' dormitories. Intensity of light required for student activities and temperature inside the rooms are the major factors for an occupant's comfortable work and life. Design of building façades has a significant impact both on the use of natural light and energy consumption. In this paper, a comparative analysis of student rooms with different orientations and different façade designs was performed in order to investigate what type of refurbishment in the façade is necessary. The goal of the refurbishment was generation of optimal thermal and lighting comfort for students' work with maximal energy saving for a new student dormitory in Nis, Serbia. An analysis of annual energy consumption of the newly designed student dormitory and proposed replacements on the exterior façade was performed by using the software EnergyPlus. Based on the energy consumption analysis it could be concluded that significant energy savings would be possible by upgrading the shading devices across the width of the window. In other words, changing the façade of the dorm could generally improve students' comfort, while the energy costs would be reduced. [Projekat Ministarstva nauke Republike Srbije, br. TR 36037: Development of student dorms in Serbia at the beginning of the 21st century i br. TR 33051: The concept of sustainable energy supply of settlements with energy efficient buildings

  19. Missouri Agricultural Energy Saving Team-A Revolutionary Opportunity (MAESTRO)

    Energy Technology Data Exchange (ETDEWEB)

    McIntosh, Jane [MDA; Schumacher, Leon [University of Missouri

    2014-10-23

    The Missouri Agricultural Energy Saving Team-A Revolutionary Opportunity (MAESTRO) program brought together a team of representatives from government, academia, and private industry to enhance the availability of energy efficiency services for small livestock producers in the State of Missouri. The Missouri Department of Agriculture (MDA) managed the project via a subcontract with the University of Missouri (MU), College of Agriculture Food and Natural Resources, MU Extension, the MU College of Human Environmental Sciences, the MU College of Engineering, and the Missouri Agricultural and Small Business Development Authority (MASBDA). MU teamed with EnSave, Inc, a nationally-recognized expert in agricultural energy efficiency to assist with marketing, outreach, provision of farm energy audits and customer service. MU also teamed with independent home contractors to facilitate energy audits of the farm buildings and homes of these livestock producers. The goals of the project were to: (1) improve the environment by reducing fossil fuel emissions and reducing the total energy used on small animal farms; (2) stimulate the economy of local and regional communities by creating or retaining jobs; and (3) improve the profitability of Missouri livestock producers by reducing their energy expenditures. Historically, Missouri scientists/engineers conducted programs on energy use in agriculture, such as in equipment, grain handling and tillage practices. The MAESTRO program was the first to focus strictly on energy efficiency associated with livestock production systems in Missouri and to investigate the applicability and potential of addressing energy efficiency in animal production from a building efficiency perspective. A. Project Objectives The goal of the MAESTRO program was to strengthen the financial viability and environmental soundness of Missouri's small animal farms by helping them implement energy efficient technologies for the production facility, farm

  20. Technical Support Document: Development of the Advanced Energy Design Guide for Grocery Stores--50% Energy Savings

    Energy Technology Data Exchange (ETDEWEB)

    Hale, E. T.; Macumber, D. L.; Long, N. L.; Griffith, B. T.; Benne, K. S.; Pless, S. D.; Torcellini, P. A.

    2008-09-01

    This report provides recommendations that architects, designers, contractors, developers, owners, and lessees of grocery store buildings can use to achieve whole-building energy savings of at least 50% over ASHRAE Standard 90.1-2004.

  1. Thermal Profiling of Residential Energy Use

    Energy Technology Data Exchange (ETDEWEB)

    Albert, A; Rajagopal, R

    2015-03-01

    This work describes a methodology for informing targeted demand-response (DR) and marketing programs that focus on the temperature-sensitive part of residential electricity demand. Our methodology uses data that is becoming readily available at utility companies-hourly energy consumption readings collected from "smart" electricity meters, as well as hourly temperature readings. To decompose individual consumption into a thermal-sensitive part and a base load (non-thermally-sensitive), we propose a model of temperature response that is based on thermal regimes, i.e., unobserved decisions of consumers to use their heating or cooling appliances. We use this model to extract useful benchmarks that compose thermal profiles of individual users, i.e., terse characterizations of the statistics of these users' temperature-sensitive consumption. We present example profiles generated using our model on real consumers, and show its performance on a large sample of residential users. This knowledge may, in turn, inform the DR program by allowing scarce operational and marketing budgets to be spent on the right users-those whose influencing will yield highest energy reductions-at the right time. We show that such segmentation and targeting of users may offer savings exceeding 100% of a random strategy.

  2. Reported Energy and Cost Savings from the DOE ESPC Program: FY 2014

    Energy Technology Data Exchange (ETDEWEB)

    Slattery, Bob S. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-03-01

    The objective of this work was to determine the realization rate of energy and cost savings from the Department of Energy’s Energy Savings Performance Contract (ESPC) program based on information reported by the energy services companies (ESCOs) that are carrying out ESPC projects at federal sites. Information was extracted from 156 Measurement and Verification (M&V) reports to determine reported, estimated, and guaranteed cost savings and reported and estimated energy savings for the previous contract year. Because the quality of the reports varied, it was not possible to determine all of these parameters for each project. For all 156 projects, there was sufficient information to compare estimated, reported, and guaranteed cost savings. For this group, the total estimated cost savings for the reporting periods addressed were $210.6 million, total reported cost savings were $215.1 million, and total guaranteed cost savings were $204.5 million. This means that on average: ESPC contractors guaranteed 97% of the estimated cost savings; projects reported achieving 102% of the estimated cost savings; and projects reported achieving 105% of the guaranteed cost savings. For 155 of the projects examined, there was sufficient information to compare estimated and reported energy savings. On the basis of site energy, estimated savings for those projects for the previous year totaled 11.938 million MMBtu, and reported savings were 12.138 million MMBtu, 101.7% of the estimated energy savings. On the basis of source energy, total estimated energy savings for the 155 projects were 19.052 million MMBtu, and reported saving were 19.516 million MMBtu, 102.4% of the estimated energy savings.

  3. Underground thermal energy storage

    CERN Document Server

    Lee, Kun Sang

    2014-01-01

    Summarizing several decades of development in UTES-strategically vital in combating global warming-this book, which includes current statistics and real-world applications, forms an excellent introduction to this widely used method of energy conservation.

  4. Annual Energy Usage Reduction and Cost Savings of a School: End-Use Energy Analysis

    Science.gov (United States)

    Alghoul, M. A.; Bakhtyar, B.; Asim, Nilofar; Sopian, K.

    2014-01-01

    Buildings are among the largest consumers of energy. Part of the energy is wasted due to the habits of users and equipment conditions. A solution to this problem is efficient energy usage. To this end, an energy audit can be conducted to assess the energy efficiency. This study aims to analyze the energy usage of a primary school and identify the potential energy reductions and cost savings. A preliminary audit was conducted, and several energy conservation measures were proposed. The energy conservation measures, with reference to the MS1525:2007 standard, were modelled to identify the potential energy reduction and cost savings. It was found that the school's usage of electricity exceeded its need, incurring an excess expenditure of RM 2947.42. From the lighting system alone, it was found that there is a potential energy reduction of 5489.06 kWh, which gives a cost saving of RM 2282.52 via the improvement of lighting system design and its operating hours. Overall, it was found that there is a potential energy reduction and cost saving of 20.7% when the energy conservation measures are earnestly implemented. The previous energy intensity of the school was found to be 50.6 kWh/m2/year, but can theoretically be reduced to 40.19 kWh/mm2/year. PMID:25485294

  5. Annual Energy Usage Reduction and Cost Savings of a School: End-Use Energy Analysis

    Directory of Open Access Journals (Sweden)

    Aiman Roslizar

    2014-01-01

    Full Text Available Buildings are among the largest consumers of energy. Part of the energy is wasted due to the habits of users and equipment conditions. A solution to this problem is efficient energy usage. To this end, an energy audit can be conducted to assess the energy efficiency. This study aims to analyze the energy usage of a primary school and identify the potential energy reductions and cost savings. A preliminary audit was conducted, and several energy conservation measures were proposed. The energy conservation measures, with reference to the MS1525:2007 standard, were modelled to identify the potential energy reduction and cost savings. It was found that the school’s usage of electricity exceeded its need, incurring an excess expenditure of RM 2947.42. From the lighting system alone, it was found that there is a potential energy reduction of 5489.06 kWh, which gives a cost saving of RM 2282.52 via the improvement of lighting system design and its operating hours. Overall, it was found that there is a potential energy reduction and cost saving of 20.7% when the energy conservation measures are earnestly implemented. The previous energy intensity of the school was found to be 50.6 kWh/m2/year, but can theoretically be reduced to 40.19 kWh/mm2/year.

  6. Energy aspects and potential energy savings of the new DASI process for milk sterilization

    Energy Technology Data Exchange (ETDEWEB)

    Frey, B.C. (Univ. of Maryland, College Park); Stewart, L.E.; Chandarana, D.; Wolfson, R.P.

    1981-01-01

    An experimental study was conducted to determine the difference in total processing energy required by the DASI ultra-high temperature (UHT) system and a conventional high temperature short time (HTST) fluid milk system. Data available in the literature were used to develop an energy use profile for the current US fluid milk system from processor to consumer. The energy data measured and the profile developed were used to estimate the potential energy savings resulting from the introduction of sterile milk in the US fluid milk market. Savings of energy resulting from the introduction of sterile milk were estimated to be 12 million barrels of oil annually.

  7. A practical review of energy saving technology for ageing populations.

    Science.gov (United States)

    Walker, Guy; Taylor, Andrea; Whittet, Craig; Lynn, Craig; Docherty, Catherine; Stephen, Bruce; Owens, Edward; Galloway, Stuart

    2017-07-01

    Fuel poverty is a critical issue for a globally ageing population. Longer heating/cooling requirements combine with declining incomes to create a problem in need of urgent attention. One solution is to deploy technology to help elderly users feel informed about their energy use, and empowered to take steps to make it more cost effective and efficient. This study subjects a broad cross section of energy monitoring and home automation products to a formal ergonomic analysis. A high level task analysis was used to guide a product walk through, and a toolkit approach was used thereafter to drive out further insights. The findings reveal a number of serious usability issues which prevent these products from successfully accessing an important target demographic and associated energy saving and fuel poverty outcomes. Design principles and examples are distilled from the research to enable practitioners to translate the underlying research into high quality design-engineering solutions. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Saving energy and protecting environment of electric vehicles

    Science.gov (United States)

    Yuan, Lina; Chen, Huajun; Gong, Jing

    2017-05-01

    With the concept of low carbon economy, saving energy, and protecting environment spread, the development of the electric promotes the research pace of wireless charging electronic vehicles, which will become the best choice of energy supply in the future. To generalize and exploit the corresponding alternative fuels and the research and development, and promotion of electric vehicles, becomes the effective means to directly reduce the consumption of fuel, effectively relieves the problem of nervous energy and environmental pollution, and really conforms to the requirements of the national strategy of sustainable development in China. This paper introduces the status of electronic cars and wireless charging, expounds the principle of wireless charging, and concludes the full text.

  9. Grant management procedure for energy saving TDM-PONs

    Science.gov (United States)

    Alaelddin, Fuad Yousif Mohammed; Newaz, S. H. Shah; AL-Hazemi, Fawaz; Choi, Jun Kyun

    2018-01-01

    In order to minimize energy consumption in Time Division Multiplexing-Passive Optical Network (TDM-PON), IEEE and ITU-T have mandated sleep mode mechanism for Optical Network Units (ONUs) in the latest TDM-PON standards (e.g. IEEE P1904.1 SIEPON, ITU-T G.sup45). The sleep mode mechanism is a promising mean for maximizing energy saving in an ONU. An ONU in sleep mode flips between sleep and active state depending on the presence or absent of upstream and downstream frames. To ensure Quality of Service (QoS) of upstream frames, the recent TDM-PON standards introduced an early wake-up mechanism, in which an ONU is forced to leave the sleep state on upstream frame arrival. When the Optical Line Terminal (OLT) of a TDM-PON allows early wake-up of its connected ONUs, it allocates gratuitous grants for the sleeping ONUs along with allocating upstream grants for the ONUs in active state. Note that, the gratuitous grants control message sent periodically by the OLT on Inter-Gratuitous grant Interval (IGI) time. After leaving sleep state due to the arrival of upstream frame, the ONU uses its allocated gratuitous grant to send a control message mentioning the amount of upstream bandwidth (upstream grant) required in order to forward the remaining frames in its buffer. However, the existing early wake-up process of ONU can lead to increase the energy consumption of an ONU. It is because of the ONU wakes-up immediately from the sleep state on arrival of the upstream frame, but even so, it needs to wait for forwarding the frame until its allocated gratuitous grant period, resulting in spending energy unnecessarily. In addition, current energy saving solution for TDM-PONs do not provide a clear solution on how to manage different types of grants (e.g. listening grant, upstream transmission grant) within a Dynamic Bandwidth Allocation (DBA) polling cycle. To address this problem, we propose a state-of-art Grant Management Procedure (GMP) in order to maximize energy saving in a TDM

  10. New Haven, Connecticut: Targeting Low-Income Household Energy Savings (City Energy: From Data to Decisions)

    Energy Technology Data Exchange (ETDEWEB)

    Strategic Priorities and Impact Analysis Team, Office of Strategic Programs

    2017-11-01

    This fact sheet "New Haven, Connecticut: Targeting Low-Income Household Energy Savings" explains how the City of New Haven used data from the U.S. Department of Energy's Cities Leading through Energy Analysis and Planning (Cities-LEAP) and the State and Local Energy Data (SLED) programs to inform its city energy planning. It is one of ten fact sheets in the "City Energy: From Data to Decisions" series.

  11. Energy efficiency improvement and cost saving opportunities forpetroleum refineries

    Energy Technology Data Exchange (ETDEWEB)

    Worrell, Ernst; Galitsky, Christina

    2005-02-15

    The petroleum refining industry in the United States is the largest in the world, providing inputs to virtually any economic sector,including the transport sector and the chemical industry. The industry operates 146 refineries (as of January 2004) around the country,employing over 65,000 employees. The refining industry produces a mix of products with a total value exceeding $151 billion. Refineries spend typically 50 percent of cash operating costs (i.e., excluding capital costs and depreciation) on energy, making energy a major cost factor and also an important opportunity for cost reduction. Energy use is also a major source of emissions in the refinery industry making energy efficiency improvement an attractive opportunity to reduce emissions and operating costs. Voluntary government programs aim to assist industry to improve competitiveness through increased energy efficiency and reduced environmental impact. ENERGY STAR (R), a voluntary program managed by the U.S. Environmental Protection Agency, stresses the need for strong and strategic corporate energy management programs. ENERGY STAR provides energy management tools and strategies for successful corporate energy management programs. This Energy Guide describes research conducted to support ENERGY STAR and its work with the petroleum refining industry.This research provides information on potential energy efficiency opportunities for petroleum refineries. This Energy Guide introduces energy efficiency opportunities available for petroleum refineries. It begins with descriptions of the trends, structure, and production of the refining industry and the energy used in the refining and conversion processes. Specific energy savings for each energy efficiency measure based on case studies of plants and references to technical literature are provided. If available, typical payback periods are also listed. The Energy Guide draws upon the experiences with energy efficiency measures of petroleum refineries worldwide

  12. Energy-Saving Analysis of Solar Heating System with PCM Storage Tank

    Directory of Open Access Journals (Sweden)

    Juan Zhao

    2018-01-01

    Full Text Available A solar heating system (SHS with a phase change material (PCM thermal storage tank is proposed with the view that traditional heat water storage tanks present several problems including large space requirements, significant heat loss and unstable system performance. An entire heating season (November–March is selected as the research period on the basis of numerical models of the SHS-PCM. In addition, taking a public building in Lhasa as the object, the heating conditions, contribution rate of solar energy, and overall energy-saving capability provided by the heating system are analyzed under different PCM storage tanks and different terminal forms. The results show that an SHS with a PCM tank provides a 34% increase in energy saving capability compared to an ordinary water tank heating system. It is suggested that the design selection parameters of the PCM storage tank should specify a daily heat storage capacity that satisfies 70~80% of the entire heating season. A floor radiant system with supply/return water temperatures of 40/35 °C provides the optimal operation and the largest energy saving capability.

  13. ANALYSIS OF ENERGY SAVING AND ENERGY EFFICIENCY ISSUES DURING OPERATION OF THE METRO ROLLING STOCK

    Directory of Open Access Journals (Sweden)

    A. V. Donchenko

    2016-06-01

    Full Text Available Purpose.Nowadays a problem of significant power consumption of the rolling stock during its operation is a current issue. In connection with staged electricity rates increase further development of the rail electric transport, including metro rolling stock is impossible without a use of modern energy saving solutions and energy-efficient systems. To solve the specified problem it is necessary to carry out analysis of measures and determine prospective directions in energy saving and increase of energy efficiency on the metro rolling stock. Methodology. Using methods of scientific analysis, generalization, comparative analysis, forecasting and using results of experimental studies, the authors determined main ways for reduction of energy consumption during operation of the metro rolling stock. Energy cost analysis for metro rolling stock of the public utility (PU «Kiev Metro» was carried out. A great number of research works of native and foreign authors concerning the above mentioned problem were analyzed. Findings. Principal directions in energy saving and increase of energy efficiency of the metro rolling stock are implementation of recuperation systems, energy storage systems and energy-efficient control systems. It was determined that implementation of recuperation and energy storage systems helps to save a considerable amount of energy, consumed for traction, but it involves substantial investments. It is pointed out that in current complicated conditions of economic development of Ukraine, use of energy-efficient control systems is a perspective direction in energy saving. Main advantage of this direction is the economic effect obtaining without significant investments. Originality. For the first time was performed potential assessment for energy saving as a result of energy-efficient control systems use at type routine rolling stock operation modes on sections «Khreschatik –Teatralnaya – Khreschatik» and «Shulyavskaya

  14. Energy Savings Potential for Pumping Water in District Heating Stations

    Directory of Open Access Journals (Sweden)

    Ioan Sarbu

    2015-05-01

    Full Text Available In district heating stations, the heat carrier is circulated between the energy source and consumers by a pumping system. Fluid handling systems, such as pumping systems, are responsible for a significant portion of the total electrical energy use. Significant opportunities exist to reduce pumping energy through smart design, retrofitting, and operating practices. Most existing systems requiring flow control make use of bypass lines, throttling valves or pump speed adjustments. The most efficient of these options is pump speed control. One of the issues in using variable-speed pumping systems, however, is the total efficiency of the electric motor/pump arrangement under a given operating condition. This paper provides a comprehensive discussion about pump control in heating stations and analyzes the energy efficiency of flow control methods. Specific attention is also given to the selection of motor types, sizing and pump duty cycle. A comparative energy analysis is performed on the hot water discharge adjustment using throttling control valves and variable-speed drives in a district heating station constructed in Romania. To correlate the pumped flow rate with the heat demand and to ensure the necessary pressure using minimum energy, an automatic system has been designed. The performances of these control methods are evaluated in two practical applications. The results show that approximately 20%–50% of total pumping energy could be saved by using the optimal control method with variable-speed pumps. Additionally, some modernization solutions to reduce the environmental impact of heating stations are described.

  15. Microclimate design methods for energy-saving houses on various site conditions in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Min Kyeong

    2008-07-09

    the air flow and observe a modification of thermal condition. And. case studies for a real house model in S. Korea are performed to evaluate energy-saving of microclimate modification. (orig.)

  16. Walmart - Saving Energy, Saving Money Through Comprehensive Retrofits, Commercial Building Energy Efficiency (Fact Sheet); Energy Efficiency & Renewable Energy (EERE)

    Energy Technology Data Exchange (ETDEWEB)

    None

    2015-03-01

    Walmart partnered with the U.S. Department of Energy (DOE) in 2009 to develop and demonstrate energy retrofits for existing buildings. The goal was to reduce energy consumption by at least 30% versus ASHRAE Standard 90.1-2007, as part of DOE's Commercial Building Partnerships (CBP) Program. The project presented here, the retrofit of a 213,000 square foot store in Centennial, Colorado, withefficiency measures across multiple building systems, is part of Walmart's ongoing environmental sustainability program, which originated in 2005.

  17. Effectiveness Of UVC Lights Irradiation To Improve Energy Saving

    Directory of Open Access Journals (Sweden)

    Sameer A. Bilal

    2015-08-01

    Full Text Available HVAC Heating Ventilation and Air conditioning is the largest consumer of energy in commercial and industrial buildings. HVAC systems account for an approximated 50 of energy use in buildings. The sources of contamination and odour comes from the growth of bacteria mold and fungus that accumulate and develop on wet surfaces of HVAC coils and drain pans causing respiratory infection cough tight chest and wheezing. Besides the effects on human health Fungal contamination that adheres to the fins of cooling coil of air handling unit AHU cause a significant increase in pressure drop across the coil and decrease in heat exchange efficiency which Leeds to loss of cooling capacity and additional energy use. To prevent the fungal and microorganism growth on the cooling coil and drain pan of HVAC systems many studies conducted but not all these solutions were sufficient to remove microbial organism from the HVAC 100 . The UV-C light options through a process known as UVGI Ultraviolet germicidal irradiation is a technology showed a significant impact to produce clean air and improve indoor air quality 16. UVGI lights produce short wavelength light kills microorganisms including viruses bacteria mold and many other fungi by disrupting their DNA. The effectiveness of UVGI installed inside HVAC systems depends on many factors and the application Methods in HVAC systems. A few studies showed whether the use of UVGI results in energy saving. The objective of this study is to find the effect of fungal growth on the cooling coil surface by using field measurements at actual operating conditions of heat transfer and air flow for a non-irradiated coil in comparison to irradiated coil .Hence evaluate if there would be an enthalpy change at the coil and document the effectiveness of UVGI coil cleaning on restoring cooling capacity and save energy.

  18. Energy savings for residential heating in two pairs of buildings achieved by implementation of actually consumed energy measuring

    Directory of Open Access Journals (Sweden)

    Živković Branislav

    2006-01-01

    Full Text Available The paper presents results of heating energy consumption measurements in two pairs of buildings in community New Belgrade for two heating seasons. Influence of these measurements on energy savings is also presented. The measurements were carried out during heating seasons 2002/03 and 2003/04 in buildings in Block 34 and 63, connected to the district heating system "Beogradske elektrane". The buildings in each pair have similar architectural and thermal characteristics. One of the buildings in a pair was "test" building and the other "control" one. In the "test" building the energy consumption for heating of each apartment was measured, as well as total energy consumption for the whole building in the substation. Occupants were able to regulate the heating system. In the "control" building the energy consumption was measured only for the whole building, and occupants had almost no impact on heating energy consumption. The comparison of energy consumption for heating in the "test" and "control" buildings is given in the paper, as well as analysis of the influence of energy consumption measurements on the achieved energy savings. .

  19. Variable speed drives principles and applications for energy cost savings

    CERN Document Server

    Spitzer, David William

    2014-01-01

    Simply put, a variable speed drive is a controller that allows a motor and its associated equipment to run at different speeds depending upon automated input from an industrial process. That in turn provides the ability to provide smoother operations, and most importantly, energy savings by slowing down machinery when a process does not have to run at full speed. Long a leading book on this technology, this new edition by industry authority David William Spitzer provides insights to improving the applications of variable speed drives. Whether you have basic knowledge or advanced knowledge, you will find this book to be an extremely useful introduction to how variable speed drivers work, how they are best applied, and what to do and what to avoid when employing them as part of an overall automated industrial enterprise, all with an eye on energy savings. Inside, you will find: A basic overview of electrical, hydraulic, and instrumentation principles of variable speed drives. Coverage of the role that variabl...

  20. Classroom HVAC: Improving ventilation and saving energy -- field study plan

    Energy Technology Data Exchange (ETDEWEB)

    Apte, Michael G.; Faulkner, David; Hodgson, Alfred T.; Sullivan, Douglas P.

    2004-10-14

    The primary goals of this research effort are to develop, evaluate, and demonstrate a very practical HVAC system for classrooms that consistently provides classrooms (CRs) with the quantity of ventilation in current minimum standards, while saving energy, and reducing HVAC-related noise levels. This research is motivated by the public benefits of energy efficiency, evidence that many CRs are under-ventilated, and public concerns about indoor environmental quality in CRs. This document provides a summary of the detailed plans developed for the field study that will take place in 2005 to evaluate the energy and IAQ performance of a new classroom HVAC technology. The field study will include measurements of HVAC energy use, ventilation rates, and IEQ conditions in 10 classrooms with the new HVAC technology and in six control classrooms with a standard HVAC system. Energy use and many IEQ parameters will be monitored continuously, while other IEQ measurements will be will be performed seasonally. Continuously monitored data will be remotely accessed via a LonWorks network. Instrument calibration plans that vary with the type of instrumentation used are established. Statistical tests will be employed to compare energy use and IEQ conditions with the new and standard HVAC systems. Strengths of this study plan include the collection of real time data for a full school year, the use of high quality instrumentation, the incorporation of many quality control measures, and the extensive collaborations with industry that limit costs to the sponsors.

  1. [Energy saving and LED lamp lighting and human health].

    Science.gov (United States)

    Deĭnego, V N; Kaptsov, V A

    2013-01-01

    The appearance of new sources of high-intensity with large proportion of blue light in the spectrum revealed new risks of their influence on the function of the eye and human health, especially for children and teenagers. There is an urgent need to reconsider the research methods of vision hygiene in conditions of energy-saving and LED bulbs lighting. On the basis of a systematic approach and knowledge of the newly discovered photosensitive receptors there was built hierarchical model of the interaction of "light environment - the eye - the system of formation of visual images - the hormonal system of the person - his psycho-physiological state." This approach allowed us to develop a range of risk for the negative impact of spectrum on the functions of the eye and human health, as well as to formulate the hygiene requirements for energy-efficient high-intensity light sources.

  2. Retroactive effects of energy-saving lamps; Netzrueckwirkungen von Energiesparlampen

    Energy Technology Data Exchange (ETDEWEB)

    Duerrenberger, G. [Forschungsstiftung Mobilkommunikation c/o ETH Zuerich (Switzerland); Klaus, G. [Maxwave AG, Zuerich (Switzerland)

    2009-11-15

    This final report for the Swiss Federal Office of Energy (SFOE) takes a look at the repercussions on the power supply network that are caused by energy-saving lamps (ESL). These effects result from the operation of the lamps' electronic ballasts which operate at high frequencies. The most noticeable network repercussions that are caused by the rapid current variations in the ESL are discussed, as are ways of considerably reducing them. As for effects on the grid, the authors state that it is not to be expected that any problematic mains feedback will result in practice, particularly not in the well-dimensioned Swiss electricity grid. The methods used in the analysis and the detailed results obtained are presented in tabular and graphical form and discussed.

  3. Considerations for Emerging Markets for Energy Savings Certificates

    Energy Technology Data Exchange (ETDEWEB)

    Friedman, B.; Bird, L.; Barbose, G.

    2008-10-01

    Early experiences with energy savings certificates (ESCs) have revealed both their merit and the challenges associated with them. In the United States, there has been little activity to date, so any lessons must be drawn from experiences in Italy, the United Kingdom (UK), France, and elsewhere. The staying power of European examples, particularly in Italy, demonstrates that ESCs can help initiate more efficiency projects. Although a robust market for renewable energy certificates (RECs) has emerged in both the voluntary and policy compliance contexts in the United States, ESCs have yet to gain significant traction. This report looks at the opportunity presented by ESCs, the unique challenges they bring, a comparison with RECs that can inform expectations about ESC market development, and the solutions and best practices early ESC market experience have demonstrated. It also examines whether there are real market barriers that have kept ESCs from being adopted and what structural features are necessary to develop effective trading programs.

  4. Energy Savings Certificate Markets: Opportunities and Implementation Barriers

    Energy Technology Data Exchange (ETDEWEB)

    Friedman, B.; Bird, L.; Barbose, G.

    2009-07-01

    Early experiences with energy savings certificates (ESCs) have revealed their merits and the challenges associated with them. While in the United States ESC markets have yet to gain significant traction, lessons can be drawn from early experiences in the states of Connecticut and New York, as well as from established markets in Italy, France, and elsewhere. The staying power of European examples demonstrates that ESCs can help initiate more efficiency projects. This article compares ESCs with renewable energy certificates (RECs), looks at the unique opportunities and challenges they present, and reviews solutions and best practices demonstrated by early ESC markets. Three major potential ESC market types are also reviewed: compliance, voluntary, and carbon. Additionally, factors that will benefit ESC markets in the United States are examined: new state EEPS policies, public interest in tools to mitigate climate change, and the growing interest in a voluntary market for ESCs.

  5. Energy Saving in Public Transport Using Renewable Energy

    Directory of Open Access Journals (Sweden)

    Vincenzo Franzitta

    2017-01-01

    Full Text Available Hydrogen produced by renewable sources represents an interesting way to reduce the energetic dependence on fossil fuels in the transportation sector. This paper shows a feasibility study for the production, storage and distribution of hydrogen in the western Sicilian context, using three different renewable sources: wind, biomass and sea wave. The objective of this study is the evaluation of the hydrogen demand, needed to replace all diesel supplied buses with electrical buses equipped with fuel cells. An economic analysis is presented with the evaluation of the avoidable greenhouse gas emissions. Four different scenarios correlate the hydrogen demand for urban transport to the renewable energy resources present in the territories and to the modern technologies available for the production of hydrogen. The study focuses on the possibility of tapping into the potential of renewable energies (wind, biomass and sea wave for the production of hydrogen by electrolysis. The use of hydrogen would reduce significantly the emissions of particulate and greenhouse gases in the urban districts under analysis.

  6. Energy saving and use of alternative energy at Kaercher; Energiesparen und alternative Energiekonzepte bei Kaercher

    Energy Technology Data Exchange (ETDEWEB)

    Leschtar, A. [Kaercher GmbH und Co KG, Winnenden (Germany)

    2006-07-01

    Summary: In 1996 already the environmental management system of the Kaercher head office in Winnenden was certified under ISO 14001. For its environmental commitment Kaercher was awarded several prizes. The company's activities comprise 1. General environmental activities: planting vegetation on the roof, promotion of environment sound mobility forms, co-operation with the Global Nature Fund, solvent free powder coatings, water recycling, biotope maintenance, continuous environmental training for staff members. 2. Internal measures with focus on energy saving and climate protection: photovoltaic, geothermal energy, solar energy, district heat supply from wood chip-fired heating station, heat recovery, energy saving driving techniques, energy saving competition, conversion to gas building heating, heat insulation. 3. Product-related measures: Kaercher standard 'environmental sound products' and environmental checklist for the development of new equipments. Research co-operation with the Technical University Darmstadt. Numerous technical modifications of Kaercher equipment to reduce environmental impacts. (orig.)

  7. Saving energy for the data collection point in WBAN network

    Science.gov (United States)

    Nguyen-Duc, Toan; Kamioka, Eiji

    2017-11-01

    Wireless sensor networking (WSN) has been rapidly developed and become essential in various domains including health care systems. Such systems use WSN to collect real-time medical sensed data, aiming at improving the patient safety. For instance, patients suffered from adverse events, i.e., cardiac or respiratory arrests, are monitored so as to prevent them from getting harm. Sensors are placed on, in or near the patients' body to continuously collect sensing data such as the electrocardiograms, blood oxygenation, breathing, and heart rate. In this case, the sensors form a subcategory of WSN called wireless body area network (WBAN). In WBAN, sensing data are sent to one or more data collection points called personal server (PS). The role of PS is important since it forwards sensed data, to a medical server via a Bluetooth/WLAN connection in real time to support storage of information and real-time diagnosis, the device can also issue a notification of an emergency status. Since PS is a battery-based device, when its battery is empty, it will disconnect the sensed medical data with the rest network. To best of our knowledge, very few studies that focus on saving energy for the PS. To this end, this work investigates the trade-off between energy consumption for wireless communication and the amount of sensing data. An energy consumption model for wireless communication has been proposed based on direct measurement using real testbed. According to our findings, it is possible to save energy for the PS by selecting suitable wireless technology to be used based on the amount of data to be transmitted.

  8. Managing Your Energy: An ENERGY STAR(R) Guide for Identifying Energy Savings in Manufacturing Plants

    Energy Technology Data Exchange (ETDEWEB)

    Worrell, Ernst; Angelini, Tana; Masanet, Eric

    2010-07-27

    In the United States, industry spends over $100 billion annually to power its manufacturing plants. Companies also spend on maintenance, capital outlay, and energy services. Improving energy efficiency is vital to reduce these costs and increase earnings. Many cost-effective opportunities to reduce energy consumption are available, and this Energy Guide discusses energy-efficiency practices and energy-efficient technologies that can be applied over a broad spectrum of companies. Strategies in the guide address hot water and steam, compressed air, pumps, motors, fans, lighting, refrigeration, and heating, ventilation, and air conditioning. This guide includes descriptions of expected energy and cost savings, based on real-world applications, typical payback periods, and references to more detailed information. The information in this Energy Guide is intended to help energy and plant managers achieve cost-effective energy reductions while maintaining product quality. Further research on the economics of all measures--as well as on their applicability to different production practices?is needed to assess their cost effectiveness at individual plants.

  9. Some Environmental and Economic Aspects of Energy Saving Measures in Houses. An estimation model for total energy consumption and emissions to air from the Norwegian dwelling stock, and a life cycle assessment method for energy saving measures in houses

    Energy Technology Data Exchange (ETDEWEB)

    Myhre, L.

    1995-12-01

    Motivated by the need to reduce the total energy consumption and the environmental load from society, this doctoral thesis discusses energy conservation measures on existing houses. Alternative additional thermal insulation measures are assessed using an interdisciplinary life cycle approach. The first task is to develop an interdisciplinary assessment method for building improvement measures, taking account of energy consumption, resource consumption, emissions to air of environmentally harmful gases, and economic costs during the entire life cycle of the building. The second task is to develop an estimation model for the total energy consumption and emissions to air of environmentally harmful gases from the dwelling stock of Norway. Finally, the third task is to assess the total energy saving potential and the total environmental benefits of energy saving measures in houses on a national level, including only life cycle analyses of additional thermal insulation measures on single houses. Chap 2 describes the dwelling stock in Norway. Chaps 3 and 4 present an estimation model for total energy consumption and emissions to air from the dwelling stock, and calculations using the model. Chaps 5 and 6 propose and use a calculation method for the assessment of additional thermal insulation measures, using a ``cradle-to-grave`` approach. Since hydroelectric power is the main energy source in this sector in Norway, estimated payback periods for emissions to air are long. But hydroelectric power saved in this sector may be used to obtain reduction in fossil fuel use in other sectors as discussed in Chap 7. Some of the topics discussed are further elaborated on in appendices. 107 refs., 39 figs, 88 tabs.

  10. Chapter 10: Peak Demand and Time-Differentiated Energy Savings Cross-Cutting Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    Energy Technology Data Exchange (ETDEWEB)

    Kurnik, Charles W [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Stern, Frank [Navigant, Boulder, CO (United States); Spencer, Justin [Navigant, Boulder, CO (United States)

    2017-10-03

    Savings from electric energy efficiency measures and programs are often expressed in terms of annual energy and presented as kilowatt-hours per year (kWh/year). However, for a full assessment of the value of these savings, it is usually necessary to consider the measure or program's impact on peak demand as well as time-differentiated energy savings. This cross-cutting protocol describes methods for estimating the peak demand and time-differentiated energy impacts of measures implemented through energy efficiency programs.

  11. The Energy Savings and Environmental Benefits for Small and Medium Enterprises by Cloud Energy Management System

    Directory of Open Access Journals (Sweden)

    Yen-Chieh Tseng

    2016-06-01

    Full Text Available Small and medium enterprises (SMES play an important role in Taiwan’s economy. The reduction of energy costs and carbon dioxide (CO2 emissions are critical to preserving the environment. This paper uses the experimental results from 65 sites, gathered over two years since 2012, to determine how the integration of Internet communication, cloud computing technologies and a cloud energy management service (cloud EMS can reduce energy consumption by cost-effective means. The EMS has three levels: infrastructure as a service (IaaS, platform as a service (PaaS and software as a service (SaaS. Working jointly with ChungHwa Telecom, Taiwan’s leading telecom service provider, data from detection devices, control devices, air-conditioning and lighting systems are all uploaded to a cloud EMS platform, to give a so called intelligent energy management network application service platform (IEN-ASP. Various energy saving management functions are developed using this platform: (1 air conditioning optimization; (2 lighting system optimization; (3 scheduling control; (4 power billing control and (5 occupancy detection and timing control. Using the international performance measurement and verification protocol (IPMVP, the energy used at the test sites, before and after the use of the IEN-ASP, are compared to calculate the energy saved. The experimental results show that there is an average energy saving of 5724 kWh per year, which represents a saving ratio of 5.84%. This translates to a total reduction in CO2 emissions of 9,926,829 kg per year. Using the data collected, a regression model is used to demonstrate the correlation between the power that is consumed, the energy that is saved and the area of the sites. Another interesting result is that, if the experimental sites are maintained by experienced electricians or other personnel and EMS protocols are followed, the energy saving can be as great as 6.59%.

  12. Information technology applications in improving energy saving; IT-sovellukset ja energiatehokkuuden kehittaeminen

    Energy Technology Data Exchange (ETDEWEB)

    Lehtonen, M.; Heine, P.; Kallonen, M. (and others)

    2007-07-01

    Energy saving is becoming more and more important issue among the many actors within the strongly developing energy field. The hourly kWh-metering represents a new step in the electrical field - the number of the hourly kWh-metered customer points is increasing rapidly and the amount of the detailed data is huge. This also enables new approaches to find energy saving potentials. This project focuses to find energy saving potentials especially in households and office buildings. In this project, the hourly-metered energy data is linked with specific customer data to identify the energy saving potential and further developing products to make the energy use more efficient. (orig.)

  13. Energy cost saving strategies in distributed power networks

    Directory of Open Access Journals (Sweden)

    Tcheukam Alain

    2016-01-01

    Full Text Available In this paper we study energy cost saving strategies in power networks in presence of prosumers. Three tips are considered: (i distributed power network architecture, (ii peak energy shaving with the integration of prosumers’ contribution, (iii Electric vehicles self-charging by means of prosumers’ production. The proposed distributed power network architecture reduces significantly the transmission costs and can reduce significantly the global energy cost up to 42 percent. Different types of prosumer who use self-charging photovoltaic systems, are able to intelligently buy energy from, or sell it, to the power grid. Therein, prosumers interact in a distributed environment during the purchase or sale of electric power using a double auction with negotiation mechanism. Using a two-step combined learning and optimization scheme, each prosumer can learn its optimal bidding strategy and forecast its energy production, consumption and storage. Our simulation results, conducted for the region of Sicily in Italy, show that the integration of prosumers can reduce peak hour costs up to 19 percent and 6 percent for eligible prosumers with electric vehicles.

  14. Analysis on energy consumption index system of thermal power plant

    Science.gov (United States)

    Qian, J. B.; Zhang, N.; Li, H. F.

    2017-05-01

    Currently, the increasingly tense situation in the context of resources, energy conservation is a realistic choice to ease the energy constraint contradictions, reduce energy consumption thermal power plants has become an inevitable development direction. And combined with computer network technology to build thermal power “small index” to monitor and optimize the management system, the power plant is the application of information technology and to meet the power requirements of the product market competition. This paper, first described the research status of thermal power saving theory, then attempted to establish the small index system and build “small index” monitoring and optimization management system in thermal power plant. Finally elaborated key issues in the field of small thermal power plant technical and economic indicators to be further studied and resolved.

  15. Carbon and energy saving markets in compressed air

    Science.gov (United States)

    Cipollone, R.

    2015-08-01

    CO2 reduction and fossil fuel saving represent two of the cornerstones of the environmental commitments of all the countries of the world. The first engagement is of a medium to long term type, and unequivocally calls for a new energetic era. The second delays in time the fossil fuel technologies to favour an energetic transition. In order to sustain the two efforts, new immaterial markets have been established in almost all the countries of the world, whose exchanges (purchases and sales) concern CO2 emissions and equivalent fossil fuels that have not been emitted or burned. This paper goes deep inside two aspects not yet exploited: specific CO2 emissions and equivalent fossil fuel burned, as a function of compressed air produced. Reference is made to the current compressor technology, carefully analysing CAGI's (Compressed Air Gas Institute) data and integrating it with the PNUEROP (European Association of manufacturers of compressors, vacuum pumps, pneumatic tools and allied equipment) contribution on the compressor European market. On the base of energy saving estimates that could be put in place, this article also estimates the financial value of the CO2 emissions and fossil fuels avoided.

  16. Energy Consumption of Insulated Material Using Thermal Effect Analysis

    OpenAIRE

    Fadzil M. A.; Norliyati M. A.; Hilmi M. A.; Ridzuan A. R.; Wan Ibrahim M. H.; Assrul R. Z.

    2017-01-01

    Wall is one of the structures elements that resist direct heat from the atmosphere. Modification on several structures is relevance to reduce filtrate thermal movement on wall. Insulation material seems to be suitable to be implemented since its purpose meets the heat resistance requirement. Insulation material applied as to generate positive impact in energy saving through reduction in total building energy consumption. Fiberglass is one of the insulation materials that can be used to insula...

  17. Thermal energy storage devices, systems, and thermal energy storage device monitoring methods

    Science.gov (United States)

    Tugurlan, Maria; Tuffner, Francis K; Chassin, David P.

    2016-09-13

    Thermal energy storage devices, systems, and thermal energy storage device monitoring methods are described. According to one aspect, a thermal energy storage device includes a reservoir configured to hold a thermal energy storage medium, a temperature control system configured to adjust a temperature of the thermal energy storage medium, and a state observation system configured to provide information regarding an energy state of the thermal energy storage device at a plurality of different moments in time.

  18. Achieving Energy Savings in Municipal Construction in Long Beach, CA

    Energy Technology Data Exchange (ETDEWEB)

    Parrish, Kristen [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Regnier, Cindy [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-01-01

    Long Beach Gas and Oil (LBGO), the public gas utility in Long Beach, California, partnered with the U.S. Department of Energy (DOE) to develop and implement solutions to build a new, low-energy modular office building that is at least 50% below requirements set by Energy Standard 90.1-2007 of the American Society of Heating, Refrigerating, and Air-conditioning Engineers (ASHRAE), the American National Standards Institute (ANSI), and the Illuminating Engineering Society of America (IESNA) as part of DOE’s Commercial Building Partnerships (CBP) program.3 The LBGO building, which demonstrates that modular construction can be very energy efficient, is expected to exceed the ASHRAE baseline by about 45%. The new 15,000-square foot (ft2) LBGO office building has two stories and houses private offices, open-plan cubicle offices, and a conference room and call center on the second floor. The building’s modular nature allowed LBGO to realize the cost benefits of fasttracked construction while saving substantial energy and reducing operational costs. The project was funded by the utility’s ratepayer revenue, which imposed a tight budget limit. The design process was a collaborative effort involving LBGO and its design-build team, Lawrence Berkeley National Laboratory (Berkeley Lab), and subcontractors Stantec (formerly Burt Hill) and LHB Inc. The team proposed efficiency measures based on computer modeling of the building in full compliance with ASHRAE 90.1-2007; in the modeled building, the lighting and cooling systems were the largest energy users, so increasing the efficiency of these systems was a top priority. Promising measures were modeled to estimate their energy performance, and each measure was evaluated for its feasibility within the budget.

  19. Economic feasibility of thermal energy storage systems

    Energy Technology Data Exchange (ETDEWEB)

    Habeebullah, B.A. [Faculty of Engineering, King Abdulaziz University, Jeddah (Saudi Arabia)

    2007-07-01

    This paper investigates the economic feasibility of both building an ice thermal storage and structure a time of rate tariff for the unique air conditioning (A/C) plant of the Grand Holy Mosque of Makkah, Saudi Arabia. The features of the building are unique where the air-conditioned 39,300 m{sup 2} zone is open to the atmosphere and the worshippers fully occupy the building five times a day, in addition hundreds of thousands of worshippers attend the blessed weekend's prayer at noontime, which escalates the peak electricity load. For economic analysis, the objective function is the daily electricity bill that includes the operation cost and the capital investment of the ice storage system. The operation cost is function of the energy imported for operating the plant in which the tariff structure, number of operating hours and the ambient temperature are parameters. The capital recovery factor is calculated for 10% interest rate and payback period of 10 years. Full and partial load storage scenarios are considered. The results showed that with the current fixed electricity rate (0.07 $/kWh), there is no gain in introducing ice storage systems for both storage schemes. Combining energy storage and an incentive time structured rate showed reasonable daily bill savings. For base tariff of 0.07 $/kWh during daytime operation and 0.016 $/kWh for off-peak period, savings were achieved for full load storage scenario. Different tariff structure is discussed and the break-even nighttime rate was determined (varies between 0.008 and 0.03 $/kWh). Partial load storage scenario showed to be unattractive where the savings for the base structured tariff was insignificant. (author)

  20. Evaluation of energy and cost savings in mobile Cloud RAN

    DEFF Research Database (Denmark)

    Checko, Aleksandra; Christiansen, Henrik Lehrmann; Berger, Michael Stübert

    2013-01-01

    The load in mobile networks is subject to variations during the day, due to user mobility and varying network average usage. Therefore, the traditional or Distributed Radio Access Network (D-RAN) architecture, where the BaseBand processing Units (BBUs) are assigned statically to a number of cells...... using OPNET Modeler. A real case scenario is built upon the mobile traffic forecast for year 2017, a number of recommendations on traffic models and a proposed C-RAN implementation. The results achieved show that the maximum statistical multiplexing gain for user plane traffic in C-RAN architecture is 4......, is sub optimal, comparing to a novel, cloud based architecture called Cloud Radio Access Network (C-RAN). In C-RAN a group of cells shares processing resources, and hence benefit from statistical multiplexing gain is expected. In this paper, the energy and cost savings in C-RAN are evaluated numerically...

  1. The Impact of Process Scaling on Scratchpad Memory Energy Savings

    Directory of Open Access Journals (Sweden)

    Bennion Redd

    2014-09-01

    Full Text Available Scratchpad memories have been shown to reduce power consumption, but the different characteristics of nanometer scale processes, such as increased leakage power, motivate an examination of how the benefits of these memories change with process scaling. Process and application characteristics affect the amount of energy saved by a scratchpad memory. Increases in leakage as a percentage of total power particularly impact applications that rarely access memory. This study examines how the benefits of scratchpad memories have changed in newer processes, based on the measured performance of the WIMS (Wireless Integrated MicroSystems microcontroller implemented in 180- and 65-nm processes and upon simulations of this microcontroller implemented in a 32-nm process. The results demonstrate that scratchpad memories will continue to improve the power dissipation of many applications, given the leakage anticipated in the foreseeable future.

  2. Can energy utilities play a role in local political energy savings programs?

    DEFF Research Database (Denmark)

    Dirckinck-Holmfeld, Kasper

    2012-01-01

    businesses to achieve GHG reductions, seven Danish municipalities (Copenhagen, Albertslund, Allerød, Ballerup, Herning, Kolding and Næstved) have joined forces in an EU LIFE project “Carbon 20”. A key element in the Carbon 20 project is to offer an energy screening free of charge for the participating...... companies. The Carbon 20 project has entered agreements with different energy consultants to provide these screenings for little or no cost - utilising a national scheme obligating the Danish energy utilities to reduce energy use among customers. However, the energy consultants are rather reluctant to offer...... the screening to small companies since the savings are rather limited in absolute terms. This article will focus on the appropriateness of using energy utilities (or consultants working on their behalf) in a local political context of engaging the local business sector in achieving energy savings and GHG...

  3. Business Model for Femtocells: Franchising for Energy Saving

    Directory of Open Access Journals (Sweden)

    Jonathan Rodriguez

    2011-12-01

    Full Text Available Purpose—The purpose of the paper is to analyze how business models are employed in mobile communications, in order to tune them to the Femtocell domain, in addition to studying other goals that can be achieved by looking at the business models in an alternative way.Design/methodology/approach—By analyzing the technologies directly linked to a business model, it would be possible to produce a taxonomy of their usage. An analysis of the value chain is used to understand how to enhance current approaches to achieve new goals.Findings—The article covers the perspective that mobile networks evolution and femtocell implementation in the mobile market can bring innovative services to the final user, by leveraging on alternative usage of business models.Research limitations/implications—The acceptance of the usage of particular business models by mobile operators can bring benefits to the final users in the form of innovative services. An example of these services is the implementation of techniques to save energy on the terminal side.Practical implications—As soon as the targeted technologies become mature, it will be possible to provide novel services to the final user, while increasing the operational and business benefits of the mobile operators.Originality/Value—A novel view on the current application of the business model is developed, and new innovative goals are shown to be achievable by novel approaches, or by traditional approaches applied in an innovative way. In particular, we show a case study where a novel service called C2POWER applies franchising (re-selling of services of broadband access, to save energy on the mobile terminal side.

  4. MUXER—A New Equipment for Energy Saving in Ethernet

    Directory of Open Access Journals (Sweden)

    Md Mehedi Hassan Onik

    2017-11-01

    Full Text Available Nowadays, the rapidly increasing energy consumption of communication equipment is an economic and environmental problem that needs to be addressed. Small Local Area Networks (LAN switches in the US alone consume about 8 TWh per year that corresponds to hundreds of millions of US dollars in electricity. A main reason is communication equipment, due to the fact that, Ethernet switches have to active all days even in low-traffic time. There are many approaches to make the switches sensitive with the different traffic load environment, but they have to put some changes to current Ethernet that cause the incompatibility issues. This paper proposes a new device called Modified Multiplexer (MUXER, which can control the power functions of switches without modifying the current Ethernet protocol. The MUXER devices are put before the switches in the network, which provide some functions to transfer incoming Media Access Control (MAC data frames to the corresponding switches managed by MUXERs. By using the proposed device, the wasted energies in the network can be reduced, especially in the specified low-traffic time. We describe the result of numerical analysis and compare detail power consumption data between a normal and a network where MUXERs are installed. In this work, the explained result shows that if a network administrator can estimate the number of MUXER needed for a particular network and install accordingly, our device can provides a significant energy saving.

  5. An inversion strategy for energy saving in smart building through wireless monitoring

    Science.gov (United States)

    Anselmi, N.; Moriyama, T.

    2017-10-01

    The building plants represent one of the main sources of power consumption and of greenhouse gases emission in urban scenarios. The efficiency of energy management is also related to the indoor environmental conditions that reflect on the user comfort. The constant monitoring of comfort indicators enables the accurate management of building plants with the final objective of reducing energy waste and satisfying the user needs. This paper presents an inversion methodology based on support vector regression for the reconstruction and forecasting of the thermal comfort of users starting from the indoor environmental features of the building. The environmental monitoring is performed by means of a wireless sensor network, which pervasively measures the spatial variability of indoor conditions. The proposed system has been experimentally validated in a real test-site to assess the advantages and the limitations in supporting the management of the building plants towards energy saving.

  6. Temperature Distribution and Thermal Performance of an Aquifer Thermal Energy Storage System

    Science.gov (United States)

    Ganguly, Sayantan

    2017-04-01

    Energy conservation and storage has become very crucial to make use of excess energy during times of future demand. Excess thermal energy can be captured and stored in aquifers and this technique is termed as Aquifer Thermal Energy Storage (ATES). Storing seasonal thermal energy in water by injecting it into subsurface and extracting in time of demand is the principle of an ATES system. Using ATES systems leads to energy savings, reduces the dependency on fossil fuels and thus leads to reduction in greenhouse gas emission. This study numerically models an ATES system to store seasonal thermal energy and evaluates the performance of it. A 3D thermo-hydrogeological numerical model for a confined ATES system is presented in this study. The model includes heat transport processes of advection, conduction and heat loss to confining rock media. The model also takes into account regional groundwater flow in the aquifer, geothermal gradient and anisotropy in the aquifer. Results show that thermal injection into the aquifer results in the generation of a thermal-front which grows in size with time. Premature thermal-breakthrough causes thermal interference in the system when the thermal-front reaches the production well and consequences in the fall of system performance and hence should be avoided. This study models the transient temperature distribution in the aquifer for different flow and geological conditions. This may be effectively used in designing an efficient ATES project by ensuring safety from thermal-breakthrough while catering to the energy demand. Based on the model results a safe well spacing is proposed. The thermal energy discharged by the system is determined and strategy to avoid the premature thermal-breakthrough in critical cases is discussed. The present numerical model is applied to simulate an experimental field study which is found to approximate the field results quite well.

  7. Development of the Advanced Energy Design Guide for K-12 Schools -- 50% Energy Savings

    Energy Technology Data Exchange (ETDEWEB)

    Bonnema, E.; Leach, M.; Pless, S.; Torcellini, P.

    2013-02-01

    This Technical Support Document (TSD) describes the process and methodology for the development of the Advanced Energy Design Guide for K-12 School Buildings: Achieving 50% Energy Savings Toward a Net Zero Energy Building (AEDG-K12) (ASHRAE et al. 2011a). The AEDG-K12 provides recommendations for achieving 50% whole-building energy savings in K-12 schools over levels achieved by following ANSI/ASHRAE/IESNA Standard 90.1-2004, Energy Standard for Buildings Except Low-Rise Residential Buildings (Standard 90.1-2004) (ASHRAE 2004b). The AEDG-K12 was developed in collaboration with the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE), the American Institute of Architects (AIA), the Illuminating Engineering Society of North America (IES), the U.S. Green Building Council (USGBC), and the U.S. Department of Energy (DOE).

  8. Simultaneous Energy Savings and IEQ Improvements in Relocatable Classrooms

    Energy Technology Data Exchange (ETDEWEB)

    Apte, Michael G.; Dibartolomeo, Dennis; Hotchi, Toshi; Hodgson, Alfred T.; Lee, Seung-Min; Liff, Shawna M.; Rainer, Leo I.; Shendell, Derek G.; Sullivan, Doug P.; Fisk, William J.

    2003-05-22

    Relocatable classrooms (RCs) are commonly used by school districts with changing demographics and enrollment sizes. We designed and constructed four energy-efficient RCs for this study to demonstrate technologies with the potential to simultaneously improve energy efficiency and indoor environmental quality (IEQ). Two were installed at each of two school districts, and energy use and IEQ parameters were monitored during occupancy. Two RCs (one per school) were finished with materials selected for reduced emissions of toxic and odorous volatile organic compounds (VOCs). Each had two HVAC systems, operated on alternate weeks, consisting of a standard heat-pump system and an indirect-direct evaporative cooling (IDEC) system with gas-fired hydronic heating. The IDEC system provides continuous outside air ventilation at {sup 3}15 CFM (7.5 L s-1) person-1, efficient particle filtration while using significantly less energy for cooling. School year long measurements included: carbon dioxide (CO2), particles, VOCs, temperature, humidity, thermal comfort, noise, meteorology, and energy use. IEQ monitoring results indicate that important ventilation-relevant indoor CO2 and health-relevant VOC concentration reductions were achieved while average cooling and heating energy costs were simultaneously reduced by 50 percent and 30 percent, respectively.

  9. Local Thermal Insulating Materials For Thermal Energy Storage ...

    African Journals Online (AJOL)

    Thermal insulation is one of the most important components of a thermal energy storage system. In this paper the thermal properties of selected potential local materials which can be used for high temperature insulation are presented. Thermal properties of seven different samples were measured. Samples consisted of: ...

  10. Construction, sanitation and energy saving; Bauen - Sanieren und Energiesparen in Backnang

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-07-01

    The contribution under consideration concerns to construction, sanitation and energy saving in Backnang (Federal Republic of Germany). Beside a lot of advertisements, this contribution reports on: (1) Sanitation and energy saving preserve environment and purse; (2) Sanitation measures and saving potentials (Sanitation of building envelopes; modernization of the facility management); (3) Energy standard of buildings; (4) Examples of sanitation; (5) Funding programs at federal, regional and local level. Furthermore, contact persons and addresses are given.

  11. Energy Saving by Novel Bed-Integrated Local Exhaust Ventilation

    DEFF Research Database (Denmark)

    Bivolarova, Mariya Petrova; Kehayova, Nushka; Melikov, Arsen Krikor

    2016-01-01

    to suck the human bio-effluents at the area of the body where they are generated before they spread in the room. The air polluted with released bio-effluents is exhausted into the mattress near the body and is either cleaned and released back in the room or is removed from the room by connecting...... the mattress to the exhaust of the room background ventilation system. Comprehensive research reveals that the method is highly efficient for removal of bio-effluents. The energy saving potential of the VM combined with constant air volume (CAV) ventilation operating at reduced ventilation rate in a single...... was used alone at 4, 6 and 12 ACH. The air exhausted through the mattress was 1.5 L/s. The occupants were present 24 hours every day including weekends. Compared to the CAV ventilation used alone at 4, 6 and 12 ACH the use of the VM in the single-bed room decreased the annual energy consumption...

  12. Economy of energy-saving structural designs; Wirtschaftlichkeit von Energiesparkonstruktionen

    Energy Technology Data Exchange (ETDEWEB)

    Meier, C. [Hochbauamt Nuernberg (Germany)

    1999-07-01

    Economical structural designs are a must. Never has there been a time when 'enough' money was on hand; the situation of public finance, too, enforces consideration of economy. Architects and engineers, in particular, are bound by their professional codes to plan economical structural designs. Moreover, economy is required by section 5 (1) of the energy conservation act. Proof of compliance with economy is a matter of financial mathematics, which can classify all energy conservation measures. The added investment cost, sorely felt, given the current, ubiquitous scarcity of funds, is put in relation to the energetic benefit (annually saved cost) in the form of an additional-cost-and-benefit ratio MNV. (orig.) [German] Wirtschaftliche Konstruktionen sind ein Muss. Nie gab es eine Zeit, in der 'genuegend' Geld vorhanden war; auch die Haushaltslage oeffentlicher Kassen erzwingt geradezu die Beachtung der Wirtschaftlichkeit. Besonders sind Architekt und Ingenieur durch die Berufsordnungen verpflichtet, wirtschaftliche Konstruktionen zu planen. Darueberhinaus wird die Wirtschaftlichkeit im Energieeinsparungsgesetz Paragraph 5 (1) gefordert. Der Nachweis hierfuer unterliegt finanzmathematischen Zusammenhaengen, die alle Energieeinsparungsmassnahmen klassifizieren koennen. Der investive Mehraufwand, bei der heutigen generellen Knappheit der Finanzmittel eine arge Belastung, wird dem energetischen Nutzen (jaehrliche Kosteneinsparung) zugeordnet (als Mehrkosten-Nutzen-Verhaeltnis MNV). (orig.)

  13. Facilitating Energy Savings through Enhanced Usability of Thermostats

    Energy Technology Data Exchange (ETDEWEB)

    Meier, Alan; Aragon, Cecilia; Peffer, Therese; Perry, Daniel; Pritoni, Marco

    2011-05-23

    Residential thermostats play a key role in controlling heating and cooling systems. Occupants often find the controls of programmable thermostats confusing, sometimes leading to higher heating consumption than when the buildings are controlled manually. A high degree of usability is vital to a programmable thermostat's effectiveness because, unlike a more efficient heating system, occupants must engage in specific actions after installation to obtain energy savings. We developed a procedure for measuring the usability of thermostats and tested this methodology with 31 subjects on five thermostats. The procedure requires first identifying representative tasks associated with the device and then testing the subjects ability to accomplish those tasks. The procedure was able to demonstrate the subjects wide ability to accomplish tasks and the influence of a device's usability on success rates. A metric based on the time to accomplish the tasks and the fraction of subjects actually completing the tasks captured the key aspects of each thermostat's usability. The procedure was recently adopted by the Energy Star Program for its thermostat specification. The approach appears suitable for quantifying usability of controls in other products, such as heat pump water heaters and commercial lighting.

  14. Reported Energy and Cost Savings from the DOE ESPC Program: FY 2015

    Energy Technology Data Exchange (ETDEWEB)

    Slattery, Bob S. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-01-01

    The objective of this work was to determine the realization rate of energy and cost savings from the Department of Energy’s Energy Savings Performance Contract (ESPC) program based on information reported by the energy services companies (ESCOs) that are carrying out ESPC projects at federal sites. Information was extracted from 151 Measurement and Verification (M&V) reports to determine reported, estimated, and guaranteed cost savings and reported and estimated energy savings for the previous contract year. Because the quality of the reports varied, it was not possible to determine all of these parameters for each project.

  15. Cool Colored Roofs to Save Energy and Improve Air Quality

    Energy Technology Data Exchange (ETDEWEB)

    Akbari, Hashem; Levinson, Ronnen; Miller, William; Berdahl, Paul

    2005-08-23

    Urban areas tend to have higher air temperatures than their rural surroundings as a result of gradual surface modifications that include replacing the natural vegetation with buildings and roads. The term ''Urban Heat Island'' describes this phenomenon. The surfaces of buildings and pavements absorb solar radiation and become extremely hot, which in turn warm the surrounding air. Cities that have been ''paved over'' do not receive the benefit of the natural cooling effect of vegetation. As the air temperature rises, so does the demand for air-conditioning (a/c). This leads to higher emissions from power plants, as well as increased smog formation as a result of warmer temperatures. In the United States, we have found that this increase in air temperature is responsible for 5-10% of urban peak electric demand for a/c use, and as much as 20% of population-weighted smog concentrations in urban areas. Simple ways to cool the cities are the use of reflective surfaces (rooftops and pavements) and planting of urban vegetation. On a large scale, the evapotranspiration from vegetation and increased reflection of incoming solar radiation by reflective surfaces will cool a community a few degrees in the summer. As an example, computer simulations for Los Angeles, CA show that resurfacing about two-third of the pavements and rooftops with reflective surfaces and planting three trees per house can cool down LA by an average of 2-3K. This reduction in air temperature will reduce urban smog exposure in the LA basin by roughly the same amount as removing the basin entire onroad vehicle exhaust. Heat island mitigation is an effective air pollution control strategy, more than paying for itself in cooling energy cost savings. We estimate that the cooling energy savings in U.S. from cool surfaces and shade trees, when fully implemented, is about $5 billion per year (about $100 per air-conditioned house).

  16. Assessment of practices and technologies of energy saving and renewable energy sources in hotels in Crete

    Energy Technology Data Exchange (ETDEWEB)

    Zografakis, Nikolaos [Regional Energy Agency of Crete, Region of Crete, 71202 Heraklion (Greece); Gillas, Konstantinos; Pollaki, Antrianna; Profylienou, Maroulitsa; Bounialetou, Fanouria [Department of Economics, University of Crete, University Campus, 74100 Rethymno (Greece); Tsagarakis, Konstantinos P. [Department of Environmental Engineering, Democritus University of Thrace, 67100 Xanthi (Greece)

    2011-05-15

    This study aims to assess the state of the art of practices and technologies of energy saving and renewable energy sources in hotels. This will contribute to determining the potential of efficient and sustainable energy technologies integration. Hotel managers were interviewed face to face and information sessions were provided. Special energy and environmental awareness campaigns, sectoral tourism programs for climate change mitigation and adaptation, supportive policies and hotel energy investments and renovation programs are some recommendations elicited from the results of this study. (author)

  17. Returns on investments in energy-saving technologies under energy price uncertainty in Dutch greenhouse horticulture

    NARCIS (Netherlands)

    Diederen, P.J.M.; Tongeren, van F.W.; Veen, van der H.B.

    2003-01-01

    Conventional net present value calculations evaluating the profitability of investments in energy-saving technologies in Dutch horticultural outlays predict a much higher rate of adoption of these technologies than is actually observed. This paper tries to explain this gap by applying a real options

  18. Potential energy savings with personalized ventilation coupled with passive chilled beams

    DEFF Research Database (Denmark)

    Lyubenova, Velina S.; Holsøe, Jan W.; Melikov, Arsen Krikor

    2011-01-01

    20% (and up to 40% when extending the temperature in the room by 2 °C above the upper limit recommended in the standards) compared to mixing ventilation only. When PV was combined with passive chilled beams, the reduction of the supplied air was up to 80%. This ventiltion strategy may lead to energy......Personalized ventilation (PV) is an individually controlled air distribution system aimed at improving inhaled air quality and thermal comfort of each occupant. Numerous studies have shown that PV may improve occupants’ health, comfort and performance in comparison with traditional total volume air...... in the present standards were considered. The most effective energy saving strategy with PV in use was to expand the upper room temperature limit as defined in the present standards. When PV was coupled with background mixing ventilation, the possible reduction of the air supplied to the room was approximately...

  19. Energy savings in Swiss compressed-air installations; Energieeinsparungen bei Druckluftanlagen in der Schweiz

    Energy Technology Data Exchange (ETDEWEB)

    Gloor, R.

    2000-07-01

    This final report for the Swiss Federal Office of Energy (SFOE) presents the results of a project that analysed the potential energy-savings of the 150,000 compressed-air units operated in Switzerland that can represent up to 25% of operational power consumption in particular industries. The various elements of compressed-air systems - compressors, distribution networks and consumers - and their potential energy-savings - are looked at. The need for an independent competence centre to provide information and advice to suppliers, planners and operators is expressed. Subventions for the promotion of energy-efficient components and energy analyses are proposed that will help save between 5% and 50% of the energy used for producing compressed air. Check lists that help suppliers propose useful energy-saving measures are considered as having the highest savings potential, particularly in large and complex installations.

  20. Technical Support Document: Development of the Advanced Energy Design Guide for Large Hospitals - 50% Energy Savings

    Energy Technology Data Exchange (ETDEWEB)

    Bonnema, E.; Leach, M.; Pless, S.

    2013-06-01

    This Technical Support Document describes the process and methodology for the development of the Advanced Energy Design Guide for Large Hospitals: Achieving 50% Energy Savings Toward a Net Zero Energy Building (AEDG-LH) ASHRAE et al. (2011b). The AEDG-LH is intended to provide recommendations for achieving 50% whole-building energy savings in large hospitals over levels achieved by following Standard 90.1-2004. The AEDG-LH was created for a 'standard' mid- to large-size hospital, typically at least 100,000 ft2, but the strategies apply to all sizes and classifications of new construction hospital buildings. Its primary focus is new construction, but recommendations may be applicable to facilities undergoing total renovation, and in part to many other hospital renovation, addition, remodeling, and modernization projects (including changes to one or more systems in existing buildings).

  1. Assessing Potential Energy Cost Savings from Increased Energy Code Compliance in Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Rosenberg, Michael I.; Hart, Philip R.; Athalye, Rahul A.; Zhang, Jian; Wang, Weimin

    2016-02-15

    The US Department of Energy’s most recent commercial energy code compliance evaluation efforts focused on determining a percent compliance rating for states to help them meet requirements under the American Recovery and Reinvestment Act (ARRA) of 2009. That approach included a checklist of code requirements, each of which was graded pass or fail. Percent compliance for any given building was simply the percent of individual requirements that passed. With its binary approach to compliance determination, the previous methodology failed to answer some important questions. In particular, how much energy cost could be saved by better compliance with the commercial energy code and what are the relative priorities of code requirements from an energy cost savings perspective? This paper explores an analytical approach and pilot study using a single building type and climate zone to answer those questions.

  2. Design and Development of an Affective Interface for Supporting Energy-saving Activities and its Evaluation

    Science.gov (United States)

    Ito, Kyoko; Tomita, Daisuke; Imaki, Tomotaka; Hongo, Taishiro; Yoshikawa, Hidekazu

    Toward a sustainable society, energy and environmental issues are very important and controversial problems, and it is expected to support various human activities for the measures by using Information Technology. The purpose of this study is to develop an affective interface for supporting people's energy-saving activities. First, a model for supporting people's energy-saving activities involving affective elements has been constructed for supporting people's energy-saving activities, based on social psychological approaches. Based on the proposed model, the requirements on an affective interface for people's energy-saving activities have been considered. In this study, the affective interface presents suitable energy-saving activities and current electric energy consumption by a character agent with a graphical shape and synthesized voice. The character agent recommends people's energy-saving activities, tells the method of energy-saving activities and the effectiveness, and so on. The affective interface for supporting energy-saving activities has been designed in detail and developed. Then, the evaluation experiment of the developed interface has been conducted, and the results of the experiments were analyzed.

  3. Voltage Controller Saves Energy, Prolongs Life of Motors

    Science.gov (United States)

    2007-01-01

    In 1985, Power Efficiency Corporation of Las Vegas licensed NASA voltage controller technology from Marshall Space Flight Center. In the following years, Power Efficiency made patented improvements to the technology and marketed the resulting products throughout the world as the Performance Controller and the Power Efficiency energy-saving soft start. Soft start gradually introduces power to an electric motor, thus eliminating the harsh, violent mechanical stresses of having the device go from a dormant state to one of full activity; prevents it from running too hot; and increases the motor's lifetime. The product can pay for itself through the reduction in electricity consumed (according to Power Efficiency, within 3 years), depending on the duty cycle of the motor and the prevailing power rates. In many instances, the purchaser is eligible for special utility rebates for the environmental protection it provides. Common applications of Power Efficiency's soft start include mixers, grinders, granulators, conveyors, crushers, stamping presses, injection molders, elevators with MG sets, and escalators. The device has been retrofitted onto equipment at major department store chains, hotels, airports, universities, and for various manufacturers

  4. Thermal performance and heat transport in aquifer thermal energy storage

    NARCIS (Netherlands)

    Sommer, W.T.; Doornenbal, P.J.; Drijver, B.C.; Gaans, van P.F.M.; Leusbrock, I.; Grotenhuis, J.T.C.; Rijnaarts, H.H.M.

    2014-01-01

    Aquifer thermal energy storage (ATES) is used for seasonal storage of large quantities of thermal energy. Due to the increasing demand for sustainable energy, the number of ATES systems has increased rapidly, which has raised questions on the effect of ATES systems on their surroundings as well as

  5. The Program Administrator Cost of Saved Energy for Utility Customer-Funded Energy Efficiency Programs

    Energy Technology Data Exchange (ETDEWEB)

    Billingsley, Megan A.; Hoffman, Ian M.; Stuart, Elizabeth; Schiller, Steven R.; Goldman, Charles A.; LaCommare, Kristina

    2014-03-19

    End-use energy efficiency is increasingly being relied upon as a resource for meeting electricity and natural gas utility system needs within the United States. There is a direct connection between the maturation of energy efficiency as a resource and the need for consistent, high-quality data and reporting of efficiency program costs and impacts. To support this effort, LBNL initiated the Cost of Saved Energy Project (CSE Project) and created a Demand-Side Management (DSM) Program Impacts Database to provide a resource for policy makers, regulators, and the efficiency industry as a whole. This study is the first technical report of the LBNL CSE Project and provides an overview of the project scope, approach, and initial findings, including: • Providing a proof of concept that the program-level cost and savings data can be collected, organized, and analyzed in a systematic fashion; • Presenting initial program, sector, and portfolio level results for the program administrator CSE for a recent time period (2009-2011); and • Encouraging state and regional entities to establish common reporting definitions and formats that would make the collection and comparison of CSE data more reliable. The LBNL DSM Program Impacts Database includes the program results reported to state regulators by more than 100 program administrators in 31 states, primarily for the years 2009–2011. In total, we have compiled cost and energy savings data on more than 1,700 programs over one or more program-years for a total of more than 4,000 program-years’ worth of data, providing a rich dataset for analyses. We use the information to report costs-per-unit of electricity and natural gas savings for utility customer-funded, end-use energy efficiency programs. The program administrator CSE values are presented at national, state, and regional levels by market sector (e.g., commercial, industrial, residential) and by program type (e.g., residential whole home programs, commercial new

  6. Energy consumption in buildings and female thermal demand

    Science.gov (United States)

    Kingma, Boris; van Marken Lichtenbelt, Wouter

    2015-12-01

    Energy consumption of residential buildings and offices adds up to about 30% of total carbon dioxide emissions; and occupant behaviour contributes to 80% of the variation in energy consumption. Indoor climate regulations are based on an empirical thermal comfort model that was developed in the 1960s (ref. ). Standard values for one of its primary variables--metabolic rate--are based on an average male, and may overestimate female metabolic rate by up to 35% (ref. ). This may cause buildings to be intrinsically non-energy-efficient in providing comfort to females. Therefore, we make a case to use actual metabolic rates. Moreover, with a biophysical analysis we illustrate the effect of miscalculating metabolic rate on female thermal demand. The approach is fundamentally different from current empirical thermal comfort models and builds up predictions from the physical and physiological constraints, rather than statistical association to thermal comfort. It provides a substantiation of the thermal comfort standard on the population level and adds flexibility to predict thermal demand of subpopulations and individuals. Ultimately, an accurate representation of thermal demand of all occupants leads to actual energy consumption predictions and real energy savings of buildings that are designed and operated by the buildings services community.

  7. Analysis of energy saving lamps for use by photosensitive individuals.

    Science.gov (United States)

    Fenton, L; Ferguson, J; Moseley, H

    2012-08-01

    Due to European legislation, the British government has begun the phase out of incandescent bulbs, to be replaced by energy-saving alternatives. The alternatives that are available on the market are Compact Fluorescent Lamps (CFL), Energy-Efficient Halogens (EEH) and Light Emitting Diodes (LED). Whilst previous research has shown that CFLs emit UVC, UVB and UVA, there is conflicting data available on whether double enveloped CFLs are a safer alternative to single enveloped CFLs for individuals suffering from photosensitivity. The emission spectra of 106 single enveloped CFLs and 65 double enveloped CFLs were measured. There were 17 different models of single enveloped CFLs, including lamps from 6 different manufacturers (ranging from 8-20 W) and 9 models of double enveloped CFLs from 6 different manufacturers (7-15 W). In addition, the emission spectra of 53 LEDs and 56 EEHs were also analysed. The LEDs consisted of 8 different models, from 3 manufacturers, spanning between 2.5 and 12 W. There were 11 models of EEH from 6 different manufacturers with wattages ranging from 28-70 W. In order to reduce sample bias, some bulbs were provided by the lighting industry federation and others were purchased randomly from local retailers. The results validate previous research in that considerable variation exists in the UV emitted from CFLs. This variation in UV levels is true, not only within different makes and models but also, surprisingly, within a box of 8 seemingly identical bulbs supplied by a single manufacturer. It was concluded that double enveloped CFLs do reduce the levels of UVC and UVB and therefore are a safer alternative for photosensitive individuals. However, as some double enveloped CFLs and EEHs do emit UVA at levels that provoke a reaction in the skin of UVA sensitive individuals, newly emerging LEDs that have minimal UV levels may provide a safer alternative.

  8. Energy-Saving Melting and Revert Reduction Technology (E-SMARRT): Use of Laser Engineered Net Shaping for Rapid Manufacturing of Dies with Protective Coatings and Improved Thermal Management

    Energy Technology Data Exchange (ETDEWEB)

    Brevick, Jerald R. [Ohio State University

    2014-06-13

    In the high pressure die casting process, molten metal is introduced into a die cavity at high pressure and velocity, enabling castings of thin wall section and complex geometry to be obtained. Traditional die materials have been hot work die steels, commonly H13. Manufacture of the dies involves machining the desired geometry from monolithic blocks of annealed tool steel, heat treating to desired hardness and toughness, and final machining, grinding and polishing. The die is fabricated with internal water cooling passages created by drilling. These materials and fabrication methods have been used for many years, however, there are limitations. Tool steels have relatively low thermal conductivity, and as a result, it takes time to remove the heat from the tool steel via the drilled internal water cooling passages. Furthermore, the low thermal conductivity generates large thermal gradients at the die cavity surfaces, which ultimately leads to thermal fatigue cracking on the surfaces of the die steel. The high die surface temperatures also promote the metallurgical bonding of the aluminum casting alloy to the surface of the die steel (soldering). In terms of process efficiency, these tooling limitations reduce the number of die castings that can be made per unit time by increasing cycle time required for cooling, and increasing downtime and cost to replace tooling which has failed either by soldering or by thermal fatigue cracking (heat checking). The objective of this research was to evaluate the feasibility of designing, fabricating, and testing high pressure die casting tooling having properties equivalent to H13 on the surface in contact with molten casting alloy - for high temperature and high velocity molten metal erosion resistance – but with the ability to conduct heat rapidly to interior water cooling passages. A layered bimetallic tool design was selected, and the design evaluated for thermal and mechanical performance via finite element analysis. H13 was

  9. Alternative Energy Saving Technology Analysis Report for Richland High School Renovation Project

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Bing

    2004-08-09

    On July 8, 2004, L&S Engineering, Inc. submitted a technical assistance request to Pacific Northwest National Laboratory (PNNL) to help estimate the potential energy savings and cost effectiveness of the solar energy and daylighting design alternatives for Richland High School Renovation Project in Richland, WA. L&S Engineering expected PNNL to evaluate the potential energy savings and energy cost savings, the probable installation costs, incentives or grants to reduce the installed costs and simple payback for the following alternative measures: (1) Daylighting in New Gym; (2) Solar Photovoltaics; (3) Solar Domestic Hot Water Pre-Heat; and (4) Solar Outside Air Pre-Heat Following are the findings of the energy savings and cost-effectiveness analysis of above alternative energy saving technologies.

  10. Energy saving opportunities in the refrigerated transport sector through Phase Change Materials (PCMs) application

    Science.gov (United States)

    Principi, P.; Fioretti, R.; Copertaro, B.

    2017-11-01

    Transportation of food products at controlled temperature is a critical task in the transport sector. In fact, whilst there is a need of ensuring both food quality and safety to the global population, its impact in terms of energy consumption and related CO2 emissions into the atmosphere is becoming increasingly evident. In this regard, Thermal Energy Storage (TES) using Phase Change Materials (PCMs) can be considered as a potential way of reducing the cooling load, energy consumption and related greenhouse gas emissions in refrigerated transport sector. In this paper two different PCM applications are investigated. Specifically, in the first study a PCM (35 °C melting temperature) layer was added to the external side of a refrigerated enclosure wall with the aim of managing the cooling peak (shifting and reducing) and reducing the daily energy rate. Outdoor experimental results showed that the added PCM layer helps to reduce (between 5.55% and 8.57%) and delay (between 4.30 h and 3.30 h) the peak load of incoming heat compared to the reference one. In the second study, the energy performance of a refrigerated chamber with an air heat exchanger containing PCM (5°C melting temperature) was investigated. The study purpose was to reduce the cooling energy consumption during steady state operating conditions and the rate of temperature increase throughout the course of a power failure event. Test results showed that using a PCM air heat exchanger addition, up to 16% of energy can be saved.

  11. Crop based climate regimes for energy saving in greenhouse cultivation

    Energy Technology Data Exchange (ETDEWEB)

    Koerner, O.

    2003-06-16

    Sustainability is one of the major aims in greenhouse horticulture. According to agreements between the Dutch grower association and the government, energy consumption and the use of chemical biocides have to be reduced. More advanced greenhouse technique is being developed to reach the target to decrease the energy efficiency-index by 65% between 1980 and 2010. However, this could also be achieved with existing technology by using more advanced climate regimes. The present thesis aimed at that, through designing and analysing climate regimes while employing existing climate control possibilities. Theoretical temperature and humidity regimes were designed to decrease energy consumption and a photosynthesis maximisation procedure was implemented to maximise growth. The basis for a crop gross photosynthesis model for control purposes was created. Crop photosynthesis models were evaluated at conditions expected to occur with more sustainable climate regimes. It was shown with experimental evidence that theoretical assumptions on the temperature - CO2 effects in a crop that are based on theoretically models scaling up leaf photosynthesis to the crop level are valid and that simplified existing models could be applied up to 28C. With higher temperatures new designs are needed and this can probably be achieved with an improved stomata-resistance model. The well known temperature integration principle was modified with two nested time-frames (24-hour and six days) and a temperature dose-response function. In a year round tomato cultivation, energy consumption was predicted to decrease with up to 9 % compared to regular temperature integration. The potential for energy saving with temperature integration is limited by humidity control when as usual fixed set points are maintained, because it counteracts temperature integration. Vents open at lower temperatures and heating is switched on at higher temperatures than required for optimal effects of temperature integration. A

  12. Communication Support Technology Research and Network Design of Mobile Energy Efficiency Test and Energy-saving Assessment System

    Directory of Open Access Journals (Sweden)

    Zhong Ming

    2015-01-01

    Full Text Available In order to solve the communication problems when the mobile energy efficiency and energy-saving assessment system is applied to energy monitoring, the authors introduced two schemes about building wireless network which is introduced based on the demand of the mobile energy efficiency test and energy-saving assessment system. These two schemes are based on WDS (Wireless Distribution System, WSN (Wireless Sensor Network, they effectively solved the problem that signals could not be transmitted through the net when the mobile energy efficiency test and energy-saving assessment system is used to monitor the monitoring points which are located underground or in an extensive area.

  13. A comparative study on optimum insulation thickness of walls and energy savings in equatorial and tropical climate

    Directory of Open Access Journals (Sweden)

    Modeste Kameni Nematchoua

    2017-06-01

    Full Text Available The increase outdoor temperature acts directly on the indoor climate of buildings. In Cameroon, the energy consumption demand in the buildings sector has been rapidly increasing in recent years; so well that energy supply does not always satisfy demand. Thermal insulation technology can be one of the leading methods for reducing energy consumption in these new buildings. However, choosing the thickness of the insulation material often causes high insulation costs. In the present study, the optimum insulation thickness, energy saving and payback period were calculated for buildings in Yaoundé and Garoua cities, located in two climatic regions in Cameroon. The economic model including the cost of insulation material and the present value of energy consumption and the cost over a life time of 22 years of the building, were used to find the optimum insulation thickness, energy saving, and payback period. Materials that extruded polystyrene were chosen and used for two typical wall structures (concrete block (HCB and compressed stabilized earth block wall (CSEB. The early cooling transmission loads, according to wall orientations and percentage of radiation blocked were calculated using the explicit finite-difference method under steady periodic conditions. As a result, it was found that the west- and east-facing walls are the least favourite in the cooling season, whereas the south and north orientations are the most economical. Although wall orientation had a significant effect on the optimum insulation thickness, it had a more significant effect on energy savings. In equatorial region (Yaoundé, for south orientation, the optimum insulation thickness was 0.08 m for an energy savings of 51.69 $/m2. Meanwhile, in tropical region (Garoua, for north orientation, the optimum insulation thickness was 0.11 m for an energy savings of 97.82 $/m2.

  14. Simulation of Energy Savings in Automotive Coatings Processes

    Science.gov (United States)

    Gerini Romagnoli, Marco

    Recently, the automakers have become more and more aware of the environmental and economic impact of their manufacturing processes. The paint shop is the largest energy user in a vehicle manufacturing plant, and one way to reduce costs and energy usage is the optimization of this area. This project aims at providing a tool to model and simulate a paint shop, in order to run and analyze some scenarios and case studies, helping to take strategic decisions. Analytical computations and real data were merged to build a tool that can be used by FCA for their Sterling Heights plant. Convection and conduction heat losses were modeled for the dip processes and the ovens. Thermal balances were used to compute the consumptions of booths, decks and ovens, while pump and fan energy consumptions were modeled for each sub-process. The user acts on a calendar, scheduling a year of production, and the model predicts the energy consumption of the paint shop. Five scenarios were run to test different conditions and the influence of scheduling on the energy consumption. Two different sets of production schedules have been evaluated, the first one fulfilling the production requirement in one shift of 10 hours, at high rate, the second one using two 7-hour-long shifts at medium production rate. It was found that the unit cost was minimized in the warmest months of spring and fall, and system shutdown was a crucial factor to reduce energy consumption. A fifth hypothetical scenario was run, with a 4 month continuous production and an 8 month total shutdown, which reduced the energy consumption to a half of the best realistic scenario. When the plant was run in a two-shifts configuration, the cost to coat a vehicle was found to be 29 with weekend shutdown, and 39 without. In the one-shift configuration, the cost was slightly higher, but the difference was less than 5%. While the fifth scenario showed a consistent reduction of the unit cost, inventory and logistic expenses deriving from the

  15. An Energy Savings Model for the Heat Treatment of Castings

    Energy Technology Data Exchange (ETDEWEB)

    Y. Rong; R. Sisson; J. Morral; H. Brody

    2006-12-31

    An integrated system of software, databases, and design rules have been developed, verified, and to be marketed to enable quantitative prediction and optimization of the heat treatment of aluminum castings to increase quality, increase productivity, reduce heat treatment cycle times and reduce energy consumption. The software predicts the thermal cycle in critical locations of individual components in a furnace, the evolution of microstructure, and the attainment of properties in heat treatable aluminum alloy castings. The model takes into account the prior casting process and the specific composition of the component. The heat treatment simulation modules can be used in conjunction with software packages for simulation of the casting process. The system is built upon a quantitative understanding of the kinetics of microstructure evolution in complex multicomponent alloys, on a quantitative understanding of the interdependence of microstructure and properties, on validated kinetic and thermodynamic databases, and validated quantitative models.

  16. Making the Business Case for Energy Savings Plus Health: Indoor Air Quality Guidelines for School Building Upgrades

    Science.gov (United States)

    The Energy Savings Plus Health Guide equips school districts to integrate indoor air quality protections into school energy efficiency retrofits and other building upgrade projects. This page describes the business case for energy savings in schools.

  17. Energy Savings Analysis of the Proposed NYStretch-Energy Code 2018

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Bing [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhang, Jian [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Chen, Yan [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Edelson, Jim [New Buildings Inst. (NBI), Portland, OR (United States); Lyles, Mark [New Buildings Inst. (NBI), Portland, OR (United States)

    2018-01-20

    This study was conducted by the Pacific Northwest National Laboratory (PNNL) in support of the stretch energy code development led by the New York State Energy Research and Development Authority (NYSERDA). In 2017 NYSERDA developed its 2016 Stretch Code Supplement to the 2016 New York State Energy Conservation Construction Code (hereinafter referred to as “NYStretch-Energy”). NYStretch-Energy is intended as a model energy code for statewide voluntary adoption that anticipates other code advancements culminating in the goal of a statewide Net Zero Energy Code by 2028. Since then, NYSERDA continues to develop the NYStretch-Energy Code 2018 edition. To support the effort, PNNL conducted energy simulation analysis to quantify the energy savings of proposed commercial provisions of the NYStretch-Energy Code (2018) in New York. The focus of this project is the 20% improvement over existing commercial model energy codes. A key requirement of the proposed stretch code is that it be ‘adoptable’ as an energy code, meaning that it must align with current code scope and limitations, and primarily impact building components that are currently regulated by local building departments. It is largely limited to prescriptive measures, which are what most building departments and design projects are most familiar with. This report describes a set of energy-efficiency measures (EEMs) that demonstrate 20% energy savings over ANSI/ASHRAE/IES Standard 90.1-2013 (ASHRAE 2013) across a broad range of commercial building types and all three climate zones in New York. In collaboration with New Building Institute, the EEMs were developed from national model codes and standards, high-performance building codes and standards, regional energy codes, and measures being proposed as part of the on-going code development process. PNNL analyzed these measures using whole building energy models for selected prototype commercial buildings and multifamily buildings representing buildings in New

  18. Local Thermal Insulating Materials For Thermal Energy Storage

    African Journals Online (AJOL)

    Unknown User

    1. Introduction. It is necessary to use thermal insulating materials around thermal energy storage systems to minimize heat losses from the systems [1]. There are varieties of insulating materials which come in various forms like loose fill, rigid boards, pipe and foam. The thermal insulation is provided by embedding insulation ...

  19. Energy-Saving Opportunities for Manufacturing Companies, International Fact Sheet (Spanish)

    Energy Technology Data Exchange (ETDEWEB)

    2010-08-01

    This English/Spanish fact sheet describes the Industrial Technologies Program Save Energy Now model and provides information on tools and resources to help manufacturing facilities reduce industrial energy intensity.

  20. Energy-Saving Opportunities for Manufacturing Companies (English/Portuguese Brochure)

    Energy Technology Data Exchange (ETDEWEB)

    2011-07-01

    This English/Portuguese brochure describes the Industrial Technologies Program Save Energy Now model and provides information on tools and resources to help manufacturing facilities reduce industrial energy intensity.

  1. Technical Support Document: 50% Energy Savings for Quick-Service Restaurants

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jian; Schrock, D. W.; Fisher, D. R.; Livchak, A.; Zabrowski, D. A.; Athalye, Rahul A.; Liu, Bing

    2010-09-30

    Document describing PNNL's project to develop a package of energy efficiency measures that demonstrate the feasibility of achieving a 50% energy savings for quick-service restaurants with a simple payback of 5 years or less.

  2. Energy efficiency monitoring and economic analysis for energy saving potential in UNITEN

    Science.gov (United States)

    Reyasudin Basir Khan, M.; Jidin, Razali; Pasupuleti, Jagadeesh; Yew, Kang Chin; Azwa Shaaya, Sharifah

    2013-06-01

    This paper discusses on energy efficiency survey for typical buildings in Universiti Tenaga Nasional (UNITEN). Undeniably, wastage of energy will cause the increase of operation cost and depletion of fossil fuel resources which contributes to the climate change issue in the world. UNITEN was commenced in the late 1990s and most of the buildings in this university are not equipped with energy management system. Such system is the solution to reduce energy use while maximizing the comfort levels of the occupants. Disregard to the energy management system, the implementation of other energy saving measures is the main objective of this paper. By taking the right measures, the energy wastage in the buildings of this university can be reduced.

  3. Potentials for energy savings and long term energy demands for Croatian households sector

    DEFF Research Database (Denmark)

    Pukšec, Tomislav; Mathiesen, Brian Vad; Duic, Neven

    2013-01-01

    demand in the future, based on careful and rational energy planning. Different financial, legal and technological mechanisms can lead to significant savings in the households sector which also leads to lesser greenhouse gas emissions and lower Croatian dependence on foreign fossil fuels....... relevant. In order to plan future energy systems it is important to know future possibilities and needs regarding energy demand for different sectors. Through this paper long term energy demand projections for Croatian households sector will be shown with a special emphasis on different mechanisms, both...... financial, legal but also technological that will influence future energy demand scenarios. It is important to see how these mechanisms influence, positive or negative, on future energy demand and which mechanism would be most influential. Energy demand predictions in this paper are based upon bottom...

  4. Potentials for energy savings and long term energy demands for Croatian households sector

    DEFF Research Database (Denmark)

    Pukšec, Tomislav; Mathiesen, Brian Vad; Duic, Neven

    2011-01-01

    demand in the future, based on careful and rational energy planning. Different financial, legal and technological mechanisms can lead to significant savings in the households sector which also leads to lesser greenhouse gas emissions and lower Croatian dependence on foreign fossil fuels....... relevant. In order to plan future energy systems it is important to know future possibilities and needs regarding energy demand for different sectors. Through this paper long term energy demand projections for Croatian households sector will be shown with a special emphasis on different mechanisms, both...... financial, legal but also technological that will influence future energy demand scenarios. It is important to see how these mechanisms influence, positive or negative, on future energy demand and which mechanism would be most influential. Energy demand predictions in this paper are based upon bottom...

  5. Energy and Energy Cost Savings Analysis of the 2015 IECC for Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jian [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Xie, YuLong [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Athalye, Rahul A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhuge, Jing Wei [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rosenberg, Michael I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hart, Philip R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Liu, Bing [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-06-01

    As required by statute (42 USC 6833), DOE recently issued a determination that ANSI/ASHRAE/IES Standard 90.1-2013 would achieve greater energy efficiency in buildings subject to the code compared to the 2010 edition of the standard. Pacific Northwest National Laboratory (PNNL) conducted an energy savings analysis for Standard 90.1-2013 in support of its determination . While Standard 90.1 is the model energy standard for commercial and multi-family residential buildings over three floors (42 USC 6833), many states have historically adopted the International Energy Conservation Code (IECC) for both residential and commercial buildings. This report provides an assessment as to whether buildings constructed to the commercial energy efficiency provisions of the 2015 IECC would save energy and energy costs as compared to the 2012 IECC. PNNL also compared the energy performance of the 2015 IECC with the corresponding Standard 90.1-2013. The goal of this analysis is to help states and local jurisdictions make informed decisions regarding model code adoption.

  6. Energy and Energy Cost Savings Analysis of the 2015 IECC for Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jian [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States); Xie, YuLong [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States); Athalye, Rahul A. [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States); Zhuge, Jing Wei [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States); Rosenberg, Michael I. [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States); Hart, Philip R. [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States); Liu, Bing [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)

    2015-09-01

    As required by statute (42 USC 6833), DOE recently issued a determination that ANSI/ASHRAE/IES Standard 90.1-2013 would achieve greater energy efficiency in buildings subject to the code compared to the 2010 edition of the standard. Pacific Northwest National Laboratory (PNNL) conducted an energy savings analysis for Standard 90.1-2013 in support of its determination . While Standard 90.1 is the model energy standard for commercial and multi-family residential buildings over three floors (42 USC 6833), many states have historically adopted the International Energy Conservation Code (IECC) for both residential and commercial buildings. This report provides an assessment as to whether buildings constructed to the commercial energy efficiency provisions of the 2015 IECC would save energy and energy costs as compared to the 2012 IECC. PNNL also compared the energy performance of the 2015 IECC with the corresponding Standard 90.1-2013. The goal of this analysis is to help states and local jurisdictions make informed decisions regarding model code adoption.

  7. Technical Support Document: 50% Energy Savings Design Technology Packages for Highway Lodging Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Wei; Gowri, Krishnan; Lane, Michael D.; Thornton, Brian A.; Rosenberg, Michael I.; Liu, Bing

    2009-09-28

    This Technical Support Document (TSD) describes the process, methodology and assumptions for development of the 50% Energy Savings Design Technology Packages for Highway Lodging Buildings, a design guidance document intended to provide recommendations for achieving 50% energy savings in highway lodging properties over the energy-efficiency levels contained in ANSI/ASHRAE/IESNA Standard 90.1-2004, Energy Standard for Buildings Except Low-Rise Residential Buildings.

  8. PROJECT MANAGEMENT AS THE BASIS FOR ENERGY SAVING IN HOUSING AND UTILITIES SECTOR

    Directory of Open Access Journals (Sweden)

    Павло Трохимович БУБЕНКО

    2017-03-01

    Full Text Available Considered a scientific approach to energy conservation issues in the housing from the standpoint of program-oriented management, when in contrast to the current practice solutions of energy saving tasks, the process is carried out based on the analysis and comparison of the costs and resource losses for each energy-saving project, and the energy-saving process is based on the provisions of the theory project management. The necessity of mandatory registration of housing construction industry sub-sectors with the utilities in the process of implementing energy-saving strategies. Proposed key areas of energy efficiency of existing and new buildings, formed components selection, programming and planning of energy saving activities at the strategic, tactical and operational levels. We studied the organizational and structural relationship of the construction sector and sub-sectors of housing and communal services in the implementation of energy-saving strategies. We prove the advantages of using the network form of organizational and economic support implementation of energy saving projects.

  9. Estimation of Energy Savings Resulting From the BestPractices Program, Fiscal Year 2002

    Energy Technology Data Exchange (ETDEWEB)

    Truett, LF

    2003-09-24

    Within the U.S. Department of Energy (DOE), the Office of Energy Efficiency and Renewable Energy (EERE) has a vision of a future with clean, abundant, reliable, and affordable energy. Within EERE, the Industrial Technologies Program (ITP), formerly the Office of Industrial Technologies, works in partnership with industry to increase energy efficiency, improve environmental performance, and boost productivity. The BestPractices (BP) Program, within ITP, works directly with industries to encourage energy efficiency. The purpose of the BP Program is to improve energy utilization and management practices in the industrial sector. The program targets distinct technology areas, including pumps, process heating, steam, compressed air, motors, and insulation. This targeting is accomplished with a variety of delivery channels, such as computer software, printed publications, Internet-based resources, technical training, technical assessments, and other technical assistance. A team of program evaluators from Oak Ridge National Laboratory (ORNL) was tasked to evaluate the fiscal year 2002 (FY02) energy savings of the program. The ORNL assessment enumerates levels of program activity for technology areas across delivery channels. In addition, several mechanisms that target multiple technology areas--e.g., Plant-wide Assessments (PWAs), the ''Energy Matters'' newsletter, and special events--are also evaluated for their impacts. When possible, the assessment relies on published reports and the Industrial Assessment Center (IAC) database for estimates of energy savings that result from particular actions. Data were also provided by ORNL, Lawrence Berkeley National Laboratory (LBNL) and Project Performance Corporation (PPC), the ITP Clearinghouse at Washington State University, the National Renewable Energy Laboratory (NREL), Energetics Inc., and the Industrial Technologies Program Office. The estimated energy savings in FY02 resulting from activities of the BP

  10. Energy saving in greenhouses can be obtained by energy balance-controlled screens

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, N. E. (Univ. of Aarhus, Faculty of Agricultural Sciences, Dept. of Horticulture, Aarslev (Denmark)), e-mail: niels.andersson@agrsci.dk

    2011-03-15

    The energy screens in two greenhouses, one clad with double acrylic and one with single glass, were controlled by an energy balance model. The parameters in the model were heat transmission coefficients, air temperature in the greenhouse and outdoors, irradiance and a single constant for the solar energy efficiency. The energy consumption, screen movements and daily light integral were compared with a glass greenhouse in which the energy screens were controlled by irradiance. In the greenhouse with light-controlled screens the set point for opening and closing of the screens was 5 Wm-2. The energy-saving screens controlled by the energy balance model opened later and closed earlier than in the greenhouse with light-controlled screens. When using the energy balance model the energy saving was 14% for the glass greenhouse and 41% for the double acrylic greenhouse compared with the glass greenhouse with light-controlled screens. The air temperature was on average similar in the three greenhouses, but when the screens were controlled by energy balance the daily light integral was approximately 10% lower and the number of hours the screens were closed was prolonged with 35% for the glass-covered greenhouse and 25% for the double acrylic-covered greenhouse compared with the greenhouse with light-controlled screens. Energy peaks in connection with operation of the screens were not reduced. During the experiment Begonia elatior, Dendranthema grandiflora (Chrysanthemum), Hedera helix, Helianthus annuus, Gerbera jamesonii and Kalanchoe blossfeldiana were grown in the greenhouses. There was a trend in prolongation of the production time when the plants were grown in the glass greenhouse with energy balance control of the screens. A lower number of flowers or inflorescences were observed for some of the plant species produced in the greenhouses with energy balance-controlled screens

  11. Impact of Extended Daylight Saving Time on National Energy Consumption Report to Congress

    Energy Technology Data Exchange (ETDEWEB)

    Belzer, D. B.; Hadley, S. W.; Chin, S-M.

    2008-10-01

    The Energy Policy Act of 2005 (Pub. L. No. 109-58; EPAct 2005) amended the Uniform Time Act of 1966 (Pub. L. No. 89-387) to increase the portion of the year that is subject to Daylight Saving Time. (15 U.S.C. 260a note) EPAct 2005 extended the duration of Daylight Saving Time in the spring by changing its start date from the first Sunday in April to the second Sunday in March, and in the fall by changing its end date from the last Sunday in October to the first Sunday in November. (15 U.S.C. 260a note) EPAct 2005 also called for the Department of Energy to evaluate the impact of Extended Daylight Saving Time on energy consumption in the United States and to submit a report to Congress. (15 U.S.C. 260a note) This report presents the results of impacts of Extended Daylight Saving Time on the national energy consumption in the United States. The key findings are: (1) The total electricity savings of Extended Daylight Saving Time were about 1.3 Tera Watt-hour (TWh). This corresponds to 0.5 percent per each day of Extended Daylight Saving Time, or 0.03 percent of electricity consumption over the year. In reference, the total 2007 electricity consumption in the United States was 3,900 TWh. (2) In terms of national primary energy consumption, the electricity savings translate to a reduction of 17 Trillion Btu (TBtu) over the spring and fall Extended Daylight Saving Time periods, or roughly 0.02 percent of total U.S. energy consumption during 2007 of 101,000 TBtu. (3) During Extended Daylight Saving Time, electricity savings generally occurred over a three- to five-hour period in the evening with small increases in usage during the early-morning hours. On a daily percentage basis, electricity savings were slightly greater during the March (spring) extension of Extended Daylight Saving Time than the November (fall) extension. On a regional basis, some southern portions of the United States exhibited slightly smaller impacts of Extended Daylight Saving Time on energy savings

  12. Energy saving and solar energy use in the University of Valencia (Spain)

    Energy Technology Data Exchange (ETDEWEB)

    Gomez-Amo, J.L.; Tena, F.; Martinez-Lozano, J.A.; Utrillas, M.P. [Universitat de Valencia (Spain). Grupo de Radiacion Solar

    2004-04-01

    Recent years have seen increasing public interest in issues related to energy saving and concern for the environment. It is important to highlight the work of public institutions in this respect. This was the motive that led the University of Valencia to finance a pilot project with the objective of studying useful initiatives for optimising energy consumption in accordance with the institution's needs as well as the incorporation of innovative and more efficient technologies. The approach was to consider various aspects ranging from the analysis of the current energy consumption and the state of the installations, through the substitution of some energy inefficient components, to the study of the possible installation of a photovoltaic solar powered electricity generation station connected to the network. Also purely technical questions on economic efficiency should not be forgotten as this could lead to a reduction in energy consumption and the optimisation of the current energy consuming equipment, since generally, it is this question that limits the possible energy saving actions. (author)

  13. Evaluation on Thermal Environment and Energy Consumption of a Demonstration Building in Ningqiang

    Science.gov (United States)

    Wang, Chen; Ma, Jinghui

    2017-08-01

    The aim of this paper is to clarify the thermal performance and environment of a demonstration building in Ningqiang, China, utilizing building indoor temperature and energy consumption simulation program EnergyPlus. Compared with the existing building model, the energy saving rate of the demonstration building model is 42.42%, 6.92% higher than that of benchmark model, based on simulation analyses.

  14. A Novel Sensor Platform Matching the Improved Version of IPMVP Option C for Measuring Energy Savings

    Directory of Open Access Journals (Sweden)

    Ching-Yuan Chang

    2013-05-01

    Full Text Available It is easy to measure energy consumption with a power meter. However, energy savings cannot be directly computed by the powers measured using existing power meter technologies, since the power consumption only reflects parts of the real energy flows. The International Performance Measurement and Verification Protocol (IPMVP was proposed by the Efficiency Valuation Organization (EVO to quantify energy savings using four different methodologies of A, B, C and D. Although energy savings can be estimated following the IPMVP, there are limitations on its practical implementation. Moreover, the data processing methods of the four IPMVP alternatives use multiple sensors (thermometer, hygrometer, Occupant information and power meter readings to simulate all facilities, in order to determine an energy usage benchmark and the energy savings. This study proposes a simple sensor platform to measure energy savings. Using usually the Electronic Product Code (EPC global standard, an architecture framework for an information system is constructed that integrates sensors data, power meter readings and occupancy conditions. The proposed sensor platform is used to monitor a building with a newly built vertical garden system (VGS. A VGS shields solar radiation and saves on energy that would be expended on air-conditioning. With this platform, the amount of energy saved in the whole facility is measured and reported in real-time. The data are compared with those obtained from detailed measurement and verification (M&V processes. The discrepancy is less than 1.565%. Using measurements from the proposed sensor platform, the energy savings for the entire facility are quantified, with a resolution of ±1.2%. The VGS gives an 8.483% daily electricity saving for the building. Thus, the results show that the simple sensor platform proposed by this study is more widely applicable than the four complicated IPMVP alternatives and the VGS is an effective tool in reducing the

  15. A novel sensor platform matching the improved version of IPMVP option C for measuring energy savings.

    Science.gov (United States)

    Tseng, Yen-Chieh; Lee, Da-Sheng; Lin, Cheng-Fang; Chang, Ching-Yuan

    2013-05-22

    It is easy to measure energy consumption with a power meter. However, energy savings cannot be directly computed by the powers measured using existing power meter technologies, since the power consumption only reflects parts of the real energy flows. The International Performance Measurement and Verification Protocol (IPMVP) was proposed by the Efficiency Valuation Organization (EVO) to quantify energy savings using four different methodologies of A, B, C and D. Although energy savings can be estimated following the IPMVP, there are limitations on its practical implementation. Moreover, the data processing methods of the four IPMVP alternatives use multiple sensors (thermometer, hygrometer, Occupant information) and power meter readings to simulate all facilities, in order to determine an energy usage benchmark and the energy savings. This study proposes a simple sensor platform to measure energy savings. Using usually the Electronic Product Code (EPC) global standard, an architecture framework for an information system is constructed that integrates sensors data, power meter readings and occupancy conditions. The proposed sensor platform is used to monitor a building with a newly built vertical garden system (VGS). A VGS shields solar radiation and saves on energy that would be expended on air-conditioning. With this platform, the amount of energy saved in the whole facility is measured and reported in real-time. The data are compared with those obtained from detailed measurement and verification (M&V) processes. The discrepancy is less than 1.565%. Using measurements from the proposed sensor platform, the energy savings for the entire facility are quantified, with a resolution of ±1.2%. The VGS gives an 8.483% daily electricity saving for the building. Thus, the results show that the simple sensor platform proposed by this study is more widely applicable than the four complicated IPMVP alternatives and the VGS is an effective tool in reducing the carbon

  16. Heat savings in energy systems with substantial distributed generation

    DEFF Research Database (Denmark)

    Østergaard, PA

    2003-01-01

    In Denmark, the integration of wind power is affected by a large amount of cogeneration of heat and power. With ancillary services supplied by large-scale condensation and combined heat and power (CHP) plants, a certain degree of large-scale generation is required regardless of momentary wind input....... A lowered district heating demand and thereby lowered CHP-bound electricity generation would appear to increase the possibility of integration wind power but due to the ancillary services supplied by CHP plants, the situation is in fact the opposite. Heat savings may not be technically feasible......, if a certain production is required regardless of whether over-all electricity generation is sufficient. This article analyses this and although heat savings do have a negative impact on the amount of wind power the system may integrate a given moment in certain cases, associated fuel savings are notable...

  17. Ocean thermal energy conversion opportunities

    Energy Technology Data Exchange (ETDEWEB)

    Perrigo, L.D.; Jensen, G.A.

    1976-05-01

    Ocean Thermal Energy Conversion is one of several different concepts for use of solar energy. Recent estimates suggest about 4 percent of our nation's energy needs in 2020 might be supplied by successful use of this concept which involves the operation of a heat engine on the temperature difference between surface and deeper ocean waters in the tropics. However, to achieve the base load power potential of this process a substantial research and development effort is needed in the next few decades. Major improvements are required for control of biofouling and corrosion and improved heat transfer systems. The thermodynamic efficiencies of this process are very low and methods for preventing film deposits are mandatory. Heat transfer cannot realistically be improved by increasing pump rates or heat transfer surfaces because of intolerable parasitic power demands or capital expenditures. The development and use of OTEC power plants also has political implications that must be accommodated. Operation of such systems must be reconciled with various international agreements, the needs of marine navigation, and national defense requirements.

  18. Management of Financing the Energy Saving in Terms of Construction Enterprises: International Experience

    Directory of Open Access Journals (Sweden)

    Klimchuk Marina N.

    2016-02-01

    Full Text Available The article is aimed at studying the experience of financing the energy saving projects by leading countries of the world from the perspective of adapting the contemporary management-regulatory conditions of technology in terms of enterprises of the construction complex of Ukraine. On the basis of a content analysis of the existing practices of implementation of energy saving and enhancing energy efficiency, the following classification has been suggested: depending on the institutional socio-economic and environmental development, in accordance with the course of sustainable development, depending on the structure of economic system, depending on both time interval and subsectoral characteristic. Based on a scientific approach to the five levels in the structure of economic systems, barriers and recommendations for their prevention in the management of energy saving in construction at each of these levels have been identified. The article proposes strategic priorities of the State policy of energy saving in the construction industry, in particular holding of energy audits and energy performance certification of buildings, increasing the share of renewable energy sources in the energy balance of country; implementation of contemporary concepts of energy saving ("Green Lease", "Passive House", "Triple Zero"; establishing consulting-information centers for promoting energy saving measures.

  19. Thermal Energy Harvesting from Wildlife

    Science.gov (United States)

    Woias, P.; Schule, F.; Bäumke, E.; Mehne, P.; Kroener, M.

    2014-11-01

    In this paper we present the measurement of temperature differences between the ambient air and the body temperature of a sheep (Heidschnucke) and its applicability for thermoelectric energy harvesting from livestock, demonstrated via the test of a specially tailored TEG system in a real-life experiment. In three measurement campaigns average temperature differences were found between 2.5 K and 3.5 K. Analytical models and FEM simulations were carried out to determine the actual thermal resistance of the sheep's fur from comparisons with the temperature measurements. With these data a thermoelectric (TEG) generator was built in a thermally optimized housing with adapted heats sink. The whole TEG system was mounted to a collar, including a data logger for recording temperature and TEG voltage. First measurements at the neck of a sheep were accomplished, with a calculated maximal average power output of 173 μW at the TEG. Taking the necessity of a low-voltage step-up converter into account, an electric output power of 54 μW is available which comes close to the power consumption of a low-power VHF tracking system.

  20. Thermal energy management process experiment

    Science.gov (United States)

    Ollendorf, S.

    1984-01-01

    The thermal energy management processes experiment (TEMP) will demonstrate that through the use of two-phase flow technology, thermal systems can be significantly enhanced by increasing heat transport capabilities at reduced power consumption while operating within narrow temperature limits. It has been noted that such phenomena as excess fluid puddling, priming, stratification, and surface tension effects all tend to mask the performance of two-phase flow systems in a 1-g field. The flight experiment approach would be to attack the experiment to an appropriate mounting surface with a 15 to 20 meter effective length and provide a heat input and output station in the form of heaters and a radiator. Using environmental data, the size, location, and orientation of the experiment can be optimized. The approach would be to provide a self-contained panel and mount it to the STEP through a frame. A small electronics package would be developed to interface with the STEP avionics for command and data handling. During the flight, heaters on the evaporator will be exercised to determine performance. Flight data will be evaluated against the ground tests to determine any anomalous behavior.

  1. Solar energy thermalization and storage device

    Science.gov (United States)

    McClelland, J.F.

    A passive solar thermalization and thermal energy storage assembly which is visually transparent is described. The assembly consists of two substantial parallel, transparent wall members mounted in a rectangular support frame to form a liquid-tight chamber. A semitransparent thermalization plate is located in the chamber, substantially paralled to and about equidistant from the transparent wall members to thermalize solar radiation which is stored in a transparent thermal energy storage liquid which fills the chamber. A number of the devices, as modules, can be stacked together to construct a visually transparent, thermal storage wall for passive solar-heated buildings.

  2. Energy saving by using natural energy from the shallow ground depths - many years operating results

    Science.gov (United States)

    Besler, Maciej; Skrzycki, Maciej; Cepiński, Wojciech

    2017-11-01

    We pay back more and more larger attention on solutions which saving energy produced from conventional fuels. This is possible to obtainment in significant quantities in fields in which use up the large quantities of energy. The formation the microclimate of interiors is an example of such situation. Especially in the case air conditioning, heating and mechanical ventilation. There is, however, a possibility of energy saving as well as considerable reducing the pollution coming from combustion of raw materials by utilising the natural renewable energy from the shallow ground. In the paper the results gained during several year of continuous measurement on the exchanger were presented. In summer periods an air cooling occurs 10-12 K, e. g. from +30 °C to +20 °C. In winter on the other hand, a preparatory preheating of the air is possible, e.g. from-18°C to about ± 0°C. It is then possible to obtain for the air conditioning system the total energy needed for cooling purposes at the summer periods, or up to 50% of the ventilation heat energy in winter picks.

  3. Energy saving by using natural energy from the shallow ground depths – many years operating results

    Directory of Open Access Journals (Sweden)

    Besler Maciej

    2017-01-01

    Full Text Available We pay back more and more larger attention on solutions which saving energy produced from conventional fuels. This is possible to obtainment in significant quantities in fields in which use up the large quantities of energy. The formation the microclimate of interiors is an example of such situation. Especially in the case air conditioning, heating and mechanical ventilation. There is, however, a possibility of energy saving as well as considerable reducing the pollution coming from combustion of raw materials by utilising the natural renewable energy from the shallow ground. In the paper the results gained during several year of continuous measurement on the exchanger were presented. In summer periods an air cooling occurs 10–12 K, e. g. from +30 °C to +20 °C. In winter on the other hand, a preparatory preheating of the air is possible, e.g. from-18°C to about ± 0°C. It is then possible to obtain for the air conditioning system the total energy needed for cooling purposes at the summer periods, or up to 50% of the ventilation heat energy in winter picks.

  4. Assessment of building integrated energy supply and energy saving schemes on a national level in Denmark

    Energy Technology Data Exchange (ETDEWEB)

    Muenster, M.; Morthorst, P.E.; Birkl, C.

    2011-06-15

    In the future, buildings will not only act as consumers of energy but as producers as well. For these ''prosumers'', energy production by use of solar panels, photovoltaics and heat pumps etc will be essential. The objective of this project was to find the most optimal combinations of building insulation and use of renewable energy sources in existing buildings in terms of economics and climate impacts. Five houses were analyzed based on different personal load, consumption profiles, solar orientation and proposed building envelope improvements and use of combinations of renewable energy systems. The results of these analyses were integrated in five scenarios to examine the consequences at national level of implementing insulation together with solar panels, photovoltaics and heat pumps in single-family houses. The simulations focused on the building period between 1961 and 1972 characterised by high building activity and low energy performance. The five scenarios - a baseline scenario, a maximum savings scenario, a maximum production scenario, and a combination scenario - showed that regardless of scenario, a consequent use of individual heat pumps leads to the greatest energy savings and CO{sub 2} reductions. (ln)

  5. Energy Savings Analysis of the Proposed Revision of the Washington D.C. Non-Residential Energy Code

    Energy Technology Data Exchange (ETDEWEB)

    Rosenberg, Michael I.; Athalye, Rahul A.; Hart, Philip R.

    2017-12-01

    This report presents the results of an assessment of savings for the proposed Washington D.C. energy code relative to ASHRAE Standard 90.1-2010. It includes annual and life cycle savings for site energy, source energy, energy cost, and carbon dioxide emissions that would result from adoption and enforcement of the proposed code for newly constructed buildings in Washington D.C. over a five year period.

  6. Permanent magnets in accelerators can save energy, space and cost

    DEFF Research Database (Denmark)

    Bødker, F.; Baandrup, L.O.; Hauge, N.

    2013-01-01

    Green Magnet® technology with close to zero electrical power consumption without the need for cooling water saves costs, space and natural resources. A compact dipole based on permanent magnets has been developed at Danfysik in collaboration with Sintex and Aarhus University. Our first Green Magnet...

  7. Selected bibliography: cost and energy savings of conservation and renewable energy technologies

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-05-01

    This bibliography is a compilation of reports on the cost and energy savings of conservation and renewable energy applications throughout the United States. It is part of an overall effort to inform utilities of technological developments in conservation and renewable energy technologies and so aid utilities in their planning process to determine the most effective and economic combination of capital investments to meet customer needs. Department of Energy assessments of the applications, current costs and cost goals for the various technologies included in this bibliography are presented. These assessments are based on analyses performed by or for the respective DOE Program Offices. The results are sensitive to a number of variables and assumptions; however, the estimates presented are considered representative. These assessments are presented, followed by some conclusions regarding the potential role of the conservation and renewable energy alternative. The approach used to classify the bibliographic citations and abstracts is outlined.

  8. Consistent cost curves for identification of optimal energy savings across industry and residential sectors

    DEFF Research Database (Denmark)

    Klinge Jacobsen, Henrik; Baldini, Mattia

    Energy savings are a key element in reaching ambitious climate targets and may contribute to increased productivity as well. For identification of the most attractive saving options cost curves for savings are constructed illustrating potentials of savings with associated costs. In optimisation...... modelling these cost options are then compared with the cost of producing energy and all savings with negative costs and cost below the cost of producing the energy including the associated externality costs are expected to be implemented. There are however several methodological issues associated...... with constructing and applying the cost curves in modelling: • Cost curves do not have the same cost interpretation across economic subsectors and end-use technologies (investment cost for equipment varies – including/excluding installation – adaptation costs – indirect production costs) • The time issue of when...

  9. Estimating potential saving with energy consumption behaviour model in higher education institutions

    Directory of Open Access Journals (Sweden)

    Mohd Hafizal Ishak

    2016-11-01

    Full Text Available Towards sustainable Higher Education Institutions (HEIs, energy consumption behaviour is one of several issues that require an attention by facilities manager. Information from the behavioural aspect would be useful for facilities manager on managing the energy and determining potential energy saving. A lack of information negatively affects this aim. Hence, this paper proposes a methodology for assessing the energy consumption behaviour with the objective determining potential energy saving. The method used energy culture framework as basis and joined with centrographic approach and multiple-regression analysis. A self-administrated survey carried out involving 1400 respondents in selected HEIs. There are four types of energy use among students in HEIs namely, 'high', 'low', ‘medium’ and 'conserve' determined from the centrographic analysis. The energy consumption behaviour model was developed and tested against the holdout sample. Through the model's application, there is a vast potential for energy savings with over 55 kWh daily among the students.

  10. Thermal engineering cuts energy use to speed production

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1999-05-01

    This article gives details of energy saving designs in manufacturing processes implemented by Mannings Thermal and Environmental Engineers of Southport. Descriptions are given of reduced energy consumption and increased production resulting from the thermoforming tool presses used in producing car trim; the introduction of heating units to preheat moulding tools in the production of high performance rubber seals; the simultaneous controlled heating of several metal tools with low voltage ceramic heating elements set in the brickwork housing having a motorised insulated cover forming a sealed heating chamber; and the conversion of a brick lined hearth furnace from electric to gas using hard wearing firebricks, gas burners, and forced cooling system. (UK)

  11. Thermal energy storage for industrial waste heat recovery

    Science.gov (United States)

    Hoffman, H. W.; Kedl, R. J.; Duscha, R. A.

    1978-01-01

    The potential is examined for waste heat recovery and reuse through thermal energy storage in five specific industrial categories: (1) primary aluminum, (2) cement, (3) food processing, (4) paper and pulp, and (5) iron and steel. Preliminary results from Phase 1 feasibility studies suggest energy savings through fossil fuel displacement approaching 0.1 quad/yr in the 1985 period. Early implementation of recovery technologies with minimal development appears likely in the food processing and paper and pulp industries; development of the other three categories, though equally desirable, will probably require a greater investment in time and dollars.

  12. Evaluation of realised energy savings with simulation models. A new policy tool for the Netherlands

    Energy Technology Data Exchange (ETDEWEB)

    Boonekamp, P.G.M. [ECN Policy Studies, Petten (Netherlands)

    2013-01-15

    This report describes a new analysis tool for the evaluation of realised energy savings, and effects of savings policy, in the Netherlands. It aims to meet the information needs of policymakers, both at national and EU level, using the monitoring results of the NL Agency. The system builds on the Protocol Monitoring Energy Savings to calculate realised savings. The innovation consists of the option to adjust energy models per sector, as already used for scenario analysis, to simulate past developments. The simulations can estimate total savings and assess the contribution of policy measures. The detailed simulation approach also enables the decomposition of energy trends into volume-effects due to growth, structural effects such as fuel substitution and import/exports, and various saving effects. As the modeling system is already used for the analysis of future trends, it enables a good comparison between ex-ante (expected) savings and ex-post (realised) savings. Finally, the system enables a faster delivery of calculation results than presently is the case.

  13. Energy savings modeling of osmotic dehydration process of pork meat in molasses

    OpenAIRE

    Filipović, Vladimir; Lončar, Biljana; Nićetin, Milica; Knežević, Violeta; Filipović, Jelena; Pezo, Lato

    2015-01-01

    The goal of the presented research is defining energy savings mathematical models of the osmotic dehydration process of pork meat in sugar beet molasses and analysing the effects of applied technological parameters in the process. Quantity of saved energy in the process of osmotic dehydration ranged from 891,57 to 1770,92 kJ·kg-1 meat. In this paper developed mathematical models of energy savings in the process of pork meat osmotic dehydration are presented. Time of the process was the most i...

  14. Methods for assessing the energy-saving efficiency of industrial symbiosis in industrial parks.

    Science.gov (United States)

    Li, Wenfeng; Cui, Zhaojie; Han, Feng

    2015-01-01

    The available energy resources are being depleted worldwide. Industrial symbiosis (IS) provides a promising approach for increasing the efficiency of energy utilization, with numerous studies reporting the superiority of this technology. However, studies quantifying the energy-saving efficiency of IS remain insufficient. This paper proposes an index system for the quantitative evaluation of the energy-saving efficiency of IS. Both energy-saving and financial indexes were selected, the former include the IS energy-saving index, the contribution rate of energy saved through IS, fractional energy savings, and cut rate of energy consumption per total output value; and the latter include the IS investment payback period, IS input-output ratio, net present value (NPV), and internal rate of return (IRR) of IS. The proposed methods were applied to a case study on the XF Industrial Park (XF IP), in the city of Liaocheng in Shandong Province of China. Three energy-saving channels using IS were found in the XF IP: (a) utilizing the energy of high-temperature materials among industrial processes, (b) recovering waste heat and steam between different processes, and (c) saving energy by sharing infrastructures. The results showed that the energy efficiency index of IS was 0.326, accounting for 34.6% of the comprehensive energy-saving index in 2011, and the fractional energy-savings were 12.42%. The index of energy consumption per total industrial output value varied from 90.9 tce/MRMB to 51.6 tce/MRMB. Thus, the cut rate of energy consumption per total industrial output value was 43.42%. The average values of the IS input-output ratio was 406.2 RMB/tce, 57.2% lower than the price of standard coal. Static investment payback period in the XF IP was 8.5 months, indicating that the XF IP began to earn profit 8.5 months after the construction of all IS modes. The NVP and IRR of each IS mode in the XF IP were greater than zero, with average values equal to 1,789.96 MRMB and 140

  15. Barriers for realisation of energy savings in buildings; Barrierer for realisering af energibesparelser i bygninger

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, O.M.

    2004-07-01

    Many years' efforts within the energy labelling area have shown large saving potentials in heating and use of electricity in buildings. At the same time it has been proved that these saving potentials, even when economically advantageous, only are cashed to a limited extent. The reason to this is ascribed to barriers that meet the individual building owner who wants to start saving energy. Most barriers are known and a lot of these have been sought overcome for some time. The questions are how many barriers still exist, have new barriers arisen and the character of these barriers. On this background the objective of this survey has been to concretize and study the barriers, which are blocking reasonable energy savings. Focus has especially been on barriers for realisation of heating savings, but through a general evaluation of energy savings of barriers other forms of energy saving methods have been taken into consideration. Special interest has been directed towards houses, typically one family houses, which are affected by the Energy Labelling Scheme. The concept barriers include all kinds of barriers, also barriers that not are acknowledged as barriers by the individual house owner, or that on closer inspection turn out to be something else than actual barriers. This note suggests an alternative inertia model, in order to create an idea of the inertness characteristic of the many house owners who understand the message but fail to act on it. (BA)

  16. Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures; January 2012 - March 2013

    Energy Technology Data Exchange (ETDEWEB)

    Jayaweera, T.; Haeri, H.

    2013-04-01

    Under the Uniform Methods Project, DOE is developing a framework and a set of protocols for determining the energy savings from specific energy efficiency measures and programs. The protocols provide a straightforward method for evaluating gross energy savings for common residential and commercial measures offered in ratepayer-funded initiatives in the United States. They represent a refinement of the body of knowledge supporting energy efficiency evaluation, measurement, and verification (EM&V) activities. This document deals with savings from the following measures: commercial and industrial lighting, commercial and industrial lighting controls, small commercial and residential unitary and split system HVAC cooling equipment, residential furnaces and boilers, residential lighting, refrigerator recycling, whole-building retrofit using billing analysis, metering, peak demand and time-differentiated energy savings, sample design, survey design and implementation, and assessing persistence and other evaluation issues.

  17. Evaluation of Savings in Energy-Efficient Public Housing in the Pacific Northwest

    Energy Technology Data Exchange (ETDEWEB)

    Gordon, A. [Washington State Univ. Extension Energy Office, Cocoa, FL (United States); Lubliner, M. [Washington State Univ. Extension Energy Office, Cocoa, FL (United States); Howard, L. [Washington State Univ. Extension Energy Office, Cocoa, FL (United States); Kunkle, R. [Washington State Univ. Extension Energy Office, Cocoa, FL (United States); Martin, E. [Washington State Univ. Extension Energy Office, Cocoa, FL (United States)

    2013-10-01

    This report presents the results of an energy performance and cost-effectiveness analysis. The Salishan phase 7 and demonstration homes were compared to Salishan phase 6 homes built to 2006 Washington State Energy Code specifications 2. Predicted annual energy savings (over Salishan phase 6) was 19% for Salishan phase 7, and between 19-24% for the demonstration homes (depending on ventilationstrategy). Approximately two-thirds of the savings are attributable to the DHP. Working with the electric utility provider, Tacoma Public Utilities, researchers conducted a billing analysis for Salishan phase 7. Median energy use for the development is 11,000 kWh; annual energy costs are $780, with a fair amount of variation dependent on size of home. Preliminary analysis of savings betweenSalishan 7 and previous phases (4 through 6) suggest savings of between 20 and 30 percent. A more comprehensive comparison between Salishan 7 and previous phases will take place in year two of this project.

  18. Evaluation of Savings in Energy-Efficient Public Housing in the Pacific Northwest

    Energy Technology Data Exchange (ETDEWEB)

    None

    2013-10-01

    This report presents the results of an energy performance and cost-effectiveness analysis. The Salishan phase 7 and demonstration homes were compared to Salishan phase 6 homes built to 2006 Washington State Energy Code specifications 2. Predicted annual energy savings (over Salishan phase 6) was 19% for Salishan phase 7, and between 19-24% for the demonstration homes (depending on ventilation strategy). Approximately two-thirds of the savings are attributable to the DHP. Working with the electric utility provider, Tacoma Public Utilities, researchers conducted a billing analysis for Salishan phase 7. Median energy use for the development is 11,000 kWh; annual energy costs are $780, with a fair amount of variation dependent on size of home. Preliminary analysis of savings between Salishan 7 and previous phases (4 through 6) suggest savings of between 20 and 30 percent. A more comprehensive comparison between Salishan 7 and previous phases will take place in year two of this project.

  19. Thermal energy storage apparatus, controllers and thermal energy storage control methods

    Science.gov (United States)

    Hammerstrom, Donald J.

    2016-05-03

    Thermal energy storage apparatus, controllers and thermal energy storage control methods are described. According to one aspect, a thermal energy storage apparatus controller includes processing circuitry configured to access first information which is indicative of surpluses and deficiencies of electrical energy upon an electrical power system at a plurality of moments in time, access second information which is indicative of temperature of a thermal energy storage medium at a plurality of moments in time, and use the first and second information to control an amount of electrical energy which is utilized by a heating element to heat the thermal energy storage medium at a plurality of moments in time.

  20. Effectiveness of energy renovations: a reassessment based on actual consumption savings

    NARCIS (Netherlands)

    Filippidou, F.; Nieboer, N.E.T.; Visscher, H.J.; Laitinen Lindström, Therese; Blume, Ylva; Regebro, Margareta; Hampus, Nina; Hiltunen, Vanja

    2017-01-01

    Energy renovations offer unique opportunities to increase the energy efficiency of the built environment and for the existing housing stock, they are the most important solution. Usually, energy savings are based on modelling calculations. However, recent research has shown that the predicted energy

  1. Potential energy savings in buildings by an urban tree planting programme in California

    Science.gov (United States)

    E.G. McPherson; J.R. Simpson

    2003-01-01

    Tree canopy cover data from aerial photographs and building energy simulations were applied to estimate energy savings from existing trees and new plantings in California. There are approximately 177.3 million energy-conserving trees in California communities and 241.6 million empty planting sites. Existing trees are projected to reduce annual air conditioning energy...

  2. 76 FR 2029 - Small Business Investment Companies-Energy Saving Qualified Investments

    Science.gov (United States)

    2011-01-12

    .... Installation-related Federal Tax Credits for Consumer Energy Efficiency: http://www.energystar.gov/index.cfm?c... more easily updated as energy efficiency standards expand to include new products and services. In... Federal or State government agencies, foundations, etc. to promote energy efficiency or energy savings...

  3. Developments in indoor sustainable plant production with emphasis on energy saving

    NARCIS (Netherlands)

    Bot, G.P.A.

    2001-01-01

    In conventional greenhouse crop production the high level of energy input conflicts with international agreements on reduction of CO2 emission. To reduce absolute energy consumption, energy friendly greenhouse systems have to be designed. If today's available technology is applied energy saving will

  4. Energy saving in data processing and communication systems.

    Science.gov (United States)

    Iazeolla, Giuseppe; Pieroni, Alessandra

    2014-01-01

    The power management of ICT systems, that is, data processing (Dp) and telecommunication (Tlc) systems, is becoming a relevant problem in economical terms. Dp systems totalize millions of servers and associated subsystems (processors, monitors, storage devices, etc.) all over the world that need to be electrically powered. Dp systems are also used in the government of Tlc systems, which, besides requiring Dp electrical power, also require Tlc-specific power, both for mobile networks (with their cell-phone towers and associated subsystems: base stations, subscriber stations, switching nodes, etc.) and for wired networks (with their routers, gateways, switches, etc.). ICT research is thus expected to investigate into methods to reduce Dp- and Tlc-specific power consumption. However, saving power may turn into waste of performance, in other words, into waste of ICT quality of service (QoS). This paper investigates the Dp and Tlc power management policies that look at compromises between power saving and QoS.

  5. Energy Saving Potentials of Phase Change Materials Applied to Lightweight Building Envelopes

    Directory of Open Access Journals (Sweden)

    Yoon-Bok Seong

    2013-10-01

    Full Text Available Phase change materials (PCMs have been considered as an innovative technology that can reduce the peak loads and heating, ventilating and air conditioning (HVAC energy consumption in buildings. Basically they are substances capable of storing or releasing thermal energy as latent heat. Because the amount of latent heat absorbed or released is much larger than the sensible heat, the application of PCMs in buildings has significant potential to reduce energy consumption. However, because each PCM has its own phase change temperature, which is the temperature at which latent heat is absorbed or released, it is important to use an appropriate PCM for the purpose of building envelope design. Therefore, this paper aims to investigate the energy saving potentials in buildings when various PCMs with different phase change temperatures are applied to a lightweight building envelope by analyzing the thermal load characteristics. As results, the annual heating load increased at every phase change temperature, but the peak heating load decreased by 3.19% with heptadecane (phase change temperature 21 °C, and the lowest indoor temperature increased by 0.86 °C with heptadecane (phase change temperature 21 °C. The annual cooling load decreased by 1.05% with dodecanol (phase change temperature 24 °C, the peak cooling load decreased by 1.30% with octadecane (phase change temperature 29 °C, and the highest indoor temperature dropped by 0.50 °C with octadecane (phase change temperature 29 °C. When the night ventilation was applied to the building HVAC system for better passive cooling performance, the annual cooling load decreased by 9.28% with dodecanol (phase change temperature 24 °C, the peak load decreased by 11.33% with octadecane (phase change temperature 29 °C, and the highest indoor temperature dropped by 0.85 °C with octadecane (phase change temperature 29 °C.

  6. Feed-in tariff for energy saving: thinking of the design

    Energy Technology Data Exchange (ETDEWEB)

    Bertoldi, Paolo; Rezessy, Silvia; Boza-Kiss, Benigna (European Commission, DG JRC, Ispra (Italy)); Oikonomou, Vlasis (SOM Research Inst., Univ. of Groningen, Groningen (Netherlands))

    2009-07-01

    Financial incentives are important for the adoption of energy efficient technologies and overcoming certain market barriers to improved energy efficiency. Such incentives are broadly used in various environmental and energy fields and are usually associated with specific technology support, rather than a general sustainable behavioural change. While the declared goal of financial support schemes is to save energy or reduce harmful emissions rather than to foster new technologies per se, it is very often encountered that such financial support for energy efficient technologies does not ensure real energy savings due to the rebound effect and remaining barriers. It is common for financial support to be given to power producers for the verified production of renewable electricity, in the form of a guaranteed financial incentive (feed-in tariff). In the energy efficiency policy research little attention has been paid to the possible use of a feed-in tariff, in the form of a fixed financial incentive based on the kWh saved by the end-user. This paper discusses the possible setup of a feed-in tariff for energy savings. The paper first explores the rationale behind and the possible functionality of a feed-in for energy savings, giving examples of similar policy tools implemented or planned. The paper looks into additionality and persistency of energy savings and explores core interactions between the feed-in and existing tools for energy efficiency. Finally, key advantages and complexities related to a feed-in tariff scheme for energy savings are discussed, intending to open a discussion and foster further research on the topic.

  7. Technical Support Document: Development of the Advanced Energy Design Guide for K-12 Schools--30% Energy Savings

    Energy Technology Data Exchange (ETDEWEB)

    Pless, S.; Torcellini, P.; Long, N.

    2007-09-01

    This Technical Support Document describes the process and methodology for the development of the Advanced Energy Design Guide for K-12 School Buildings (K-12 AEDG), a design guidance document intended to provide recommendations for achieving 30% energy savings in K-12 Schools over levels contained in ANSI/ASHRAE/IESNA Standard 90.1-1999, Energy Standard for Buildings Except Low-Rise Residential Buildings. The 30% energy savings target is the first step toward achieving net-zero energy schools; schools that, on an annual basis, draw from outside sources less or equal energy than they generate on site from renewable energy sources.

  8. Directions of organisational and low-cost energy saving of engineering enterprises

    Directory of Open Access Journals (Sweden)

    Dzhedzhula Viacheslav V.

    2014-01-01

    Full Text Available The article analyses directions of energy saving of industrial enterprises. Taking into account the tendency to continuous growth of cost of energy resources, introduction of measures that would allow reduction of energy consumption of enterprises is an urgent task. One of the most important obstacles in the process of introduction of energy efficient solutions are fund limits and low awareness of owners and managers of industrial enterprises. The article offers a new classification of energy saving measures: apart from traditional expense and organisation measures it introduces the low-cost measures notion. It offers to consider low-cost those measures that are realised by the enterprise by means of own funds, moreover, their repayment term is not more than one year. It offers analytical expression for identification of annual funds saving from introduction of low-cost measures. It considers the process of identification of saving of funds from introduction of some of the main low-cost measures in detail: replacement of lighting units, balancing of ventilation networks and elimination of water leakages from pipelines and water supply equipment. Based on the analysis of bibliography information the article provides a list of main measures on energy saving, which could be referred to the low-cost ones. The proposed approaches would allow paying more attention to practical aspects of realisation of the concept of energy saving in the industry.

  9. Fan System Optimization Improves Ventilation and Saves Energy at a Computer Chip Manufacturer

    Energy Technology Data Exchange (ETDEWEB)

    None

    2002-01-01

    This case study describes an optimization project implemented on a fan system at Ash Grove Cement Company, which led to annual energy and maintenance savings of $16,000 and 175,000 kilowatt-hours (kWh).

  10. Occupancy-driven smart register for building energy saving (Conference Presentation)

    Science.gov (United States)

    Chen, Zhangjie; Wang, Ya S.

    2017-04-01

    The new era in energy-efficiency building is to integrate automatic occupancy detection with automated heating, ventilation and cooling (HVAC), the largest source of building energy consumption. By closing off some air vents, during certain hours of the day, up to 7.5% building energy consumption could be saved. In the past, smart vent has received increasing attention and several products have been developed and introduced to the market for building energy saving. For instance, Ecovent Systems Inc. and Keen Home Inc. have both developed smart vent registers capable of turning the vent on and off through smart phone apps. However, their products do not have on-board occupancy sensors and are therefore open-loop. Their vent control was achieved by simply positioning the vent blade through a motor and a controller without involving any smart actuation. This paper presents an innovative approach for automated vent control and automatic occupancy (human subjects) detection. We devise this approach in a smart register that has polydimethylsiloxane (PDMS) frame with embedded Shape memory alloy (SMA) actuators. SMAs belong to a class of shape memory materials (SMMs), which have the ability to `memorise' or retain their previous form when subjected to certain stimulus such as thermomechanical or magnetic variations. And it can work as actuators and be applied to vent control. Specifically, a Ni-Ti SMA strip will be pre-trained to a circular shape, wrapped with a Ni-Cr resistive wire that is coated with thermally conductive and electrically isolating material. Then, the SMA strip along with an antagonistic SMA strip will be bonded with PZT sensor and thermal sensors, to be inserted into a 3D printed mould which will be filled with silicone rubber materials. In the end, a demoulding process yields a fully integrated blade of the smart register. Several blades are installed together to form the smart register. The PZT sensors can feedback the shape of the actuator for precise

  11. Analysis of Installed Measures and Energy Savings for Single-Family Residential Better Buildings Projects

    Energy Technology Data Exchange (ETDEWEB)

    Heaney, M. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Polly, B. [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2015-04-30

    This report presents an analysis of data for residential single-family projects reported by 37 organizations that were awarded federal financial assistance (cooperative agreements or grants) by the U.S. Department of Energy’s Better Buildings Neighborhood Program.1 The report characterizes the energy-efficiency measures installed for single-family residential projects and analyzes energy savings and savings prediction accuracy for measures installed in a subset of those projects.

  12. Persistence of energy savings: What do we know and how can it be ensured

    Energy Technology Data Exchange (ETDEWEB)

    Vine, E.

    1992-05-01

    This paper presents a conceptual framework for analyzing persistence of energy savings, summarizes the limited experience of what we know about persistence, provides guidance for conducting retrospective and prospective persistence studies, and suggests strategies for ensuring persistence. Because this area of research is in its infancy, unequivocal conclusions about persistence would be premature. Accordingly, this paper provides guidance for both conducting research in this area and developing policies and mechanisms to help ensure the persistence of energy savings.

  13. Trend of Energy Saving in Electronic Devices for Research and Development

    OpenAIRE

    Rahmayanti R.; Utomo S.; Rijanto E.

    2016-01-01

    In electronic industry, energy saving is one of the performance indicators of competitiveness beside price, speed, bandwidth and reliability. This affects research and development (R&D) activity in mechatronic systems which uses electronic components and electronic systems. A review of trend of electronic devices technology development has been conducted with focus on energy saving. This review includes electronic devices, semiconductor, and nanotechnology. It can be concluded that the trend ...

  14. Energy-saving operation of a converter-fed synchronous machine

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, I.; Veszpremi, K. [Technical University of Budapest, Department of Electrical Machines and Drives, Budapest (Hungary)

    1997-12-31

    In the Converter-Fed Synchronous Machine (CFSM) there is no need for forced commutation the CL and CF converters operate with line commutation, the CM is commutated by the machine voltages. This drive is applied mainly for large power and high speed controlled drives. Considering the large power, the investigation of energy-saving operation is important. As in the DC and the induction motor drives the energy-saving operation is implemented by flux control. (orig.) 6 refs.

  15. Thermal energy and the origin of life.

    Science.gov (United States)

    Muller, Anthonie W J; Schulze-Makuch, Dirk

    2006-04-01

    Life has evolved on Earth with electromagnetic radiation (light), fermentable organic molecules, and oxidizable chemicals as sources of energy. Biological use of thermal energy has not been observed although heat, and the thermal gradients required to convert it into free energy, are ubiquitous and were even more abundant at the time of the origin of life on Earth. Nevertheless, Earth-organisms sense thermal energy, and in suitable environments may have gained the capability to use it as energy source. It has been proposed that the first organisms obtained their energy by a first protein named pF(1) that worked on a thermal variation of the binding change mechanism of today's ATP sythase enzyme. Organisms using thermosynthesis may still live where light or chemical energy sources are not available. Possible suitable examples are subsurface environments on Earth and in the outer Solar System, in particular the subsurface oceans of the icy satellites of Jupiter and Saturn.

  16. The solar greenhouse: a survey of energy saving methods

    NARCIS (Netherlands)

    Saye, A.; Loon, van W.K.P.; Bot, G.P.A.; Zwart, de H.F.

    2000-01-01

    The solar greenhouse project is aimed at the development of a greenhouse concept for the Netherlands with zero-fossil energy consumption. The solar greenhouse is formulated as a combination of a low energy demand greenhouse, an energy recovery installation and an energy storage facility. In this

  17. Energy Savings Potential and Research, Development, & Demonstration Opportunities for Commercial Building Appliances

    Energy Technology Data Exchange (ETDEWEB)

    Zogg, Robert [Navigant Consulting, Inc., Burlington, MA (United States); Goetzler, William [Navigant Consulting, Inc., Burlington, MA (United States); Ahlfeldt, Christopher [Navigant Consulting, Inc., Burlington, MA (United States); Hiraiwa, Hirokazu [Navigant Consulting, Inc., Burlington, MA (United States); Sathe, Amul [Navigant Consulting, Inc., Burlington, MA (United States); Sutherland, Timothy [Navigant Consulting, Inc., Burlington, MA (United States)

    2009-12-01

    This study characterizes and assesses the appliances used in commercial buildings. The primary objectives of this study were to document the energy consumed by commercial appliances and identify research, development and demonstration (RD&D) opportunities for efficiency improvements, excluding product categories such as HVAC, building lighting, refrigeration equipment, and distributed generation systems. The study included equipment descriptions, characteristics of the equipment’s market, national energy consumption, estimates of technical potential for energy-saving technologies, and recommendations for U.S. Department of Energy programs that can promote energy savings in commercial appliances.

  18. Achieving 50% Energy Savings in New Schools, Advanced Energy Design Guides: K-12 Schools (Brochure)

    Energy Technology Data Exchange (ETDEWEB)

    2014-09-01

    This fact sheet summarizes recommendations for designing elementary, middle, and high school buildings that will result in 50% less energy use than conventional new schools built to minimum code requirements. The recommendations are drawn from the Advanced Energy Design Guide for K-12 School Buildings, an ASHRAE publication that provides comprehensive recommendations for designing low-energy-use school buildings (see sidebar). Designed as a stand-alone document, this fact sheet provides key principles and a set of prescriptive design recommendations appropriate for smaller schools with insufficient budgets to fully implement best practices for integrated design and optimized performance. The recommendations have undergone a thorough analysis and review process through ASHRAE, and have been deemed the best combination of measures to achieve 50% savings in the greatest number of schools.

  19. Tourists' attitudes for selecting accommodation with investments in renewable energy and energy saving systems

    Energy Technology Data Exchange (ETDEWEB)

    Tsagarakis, Konstantinos P. [Department of Environmental Engineering, Democritus University of Thrace, 67100 Xanthi (Greece); Bounialetou, Fanouria; Gillas, Konstantinos; Profylienou, Maroulitsa; Pollaki, Antrianna [Department of Economics, University of Crete, University Campus, 74100 Rethymno (Greece); Zografakis, Nikolaos [Regional Energy Agency of Crete, Region of Crete, 71202 Heraklion (Greece)

    2011-02-15

    This paper aims at providing useful insights into tourists' preferences for choosing to stay in hotels equipped with Energy Saving Installations (ESI) and Renewable Energy Sources (RES). Factors related to these decisions were studied through 2308 face to face interviews taken at the departure terminals of the two international airports of Crete, Greece. Results show that 86% of the respondents would prefer to stay in hotels equipped with ESI, and 87% in hotels with RES, rather than staying in hotels of identical quality which do not have either ESI or RES. Furthermore, the percentages of respondents who would be willing to pay fee surcharges for a hotel equipped with ESI or RES are 75 and 77%, respectively, as compared to hotels of identical quality which do not have either ESI or RES. Tourists from countries with high energy awareness, prove to be more willing to choose to stay at and pay for hotels with ESI and RES. (author)

  20. Achieving 50% Energy Savings in Office Buildings, Advanced Energy Design Guides: Office Buildings (Brochure)

    Energy Technology Data Exchange (ETDEWEB)

    2014-09-01

    This fact sheet summarizes recommendations for designing new office buildings that result in 50% less energy use than conventional designs meeting minimum code requirements. The recommendations are drawn from the Advanced Energy Design Guide for Small to Medium Office Buildings, an ASHRAE publication that provides comprehensive recommendations for designing low-energy-use office buildings with gross floor areas up to 100,000 ft2 (see sidebar). Designed as a stand-alone document, this fact sheet provides key principles and a set of prescriptive design recommendations appropriate for smaller office buildings with insufficient budgets to fully implement best practices for integrated design and optimized performance. The recommendations have undergone a thorough analysis and review process through ASHRAE, and have been deemed the best combination of measures to achieve 50% savings in the greatest number of office buildings.

  1. [Thermal energy utilization analysis and energy conservation measures of fluidized bed dryer].

    Science.gov (United States)

    Xing, Liming; Zhao, Zhengsheng

    2012-07-01

    To propose measures for enhancing thermal energy utilization by analyzing drying process and operation principle of fluidized bed dryers,in order to guide optimization and upgrade of fluidized bed drying equipment. Through a systematic analysis on drying process and operation principle of fluidized beds,the energy conservation law was adopted to calculate thermal energy of dryers. The thermal energy of fluidized bed dryers is mainly used to make up for thermal consumption of water evaporation (Qw), hot air from outlet equipment (Qe), thermal consumption for heating and drying wet materials (Qm) and heat dissipation to surroundings through hot air pipelines and cyclone separators. Effective measures and major approaches to enhance thermal energy utilization of fluidized bed dryers were to reduce exhaust gas out by the loss of heat Qe, recycle dryer export air quantity of heat, preserve heat for dry towers, hot air pipes and cyclone separators, dehumidify clean air in inlets and reasonably control drying time and air temperature. Such technical parameters such air supply rate, air inlet temperature and humidity, material temperature and outlet temperature and humidity are set and controlled to effectively save energy during the drying process and reduce the production cost.

  2. Water and energy saving at Dutch pastry factory Verkade; Koekjesbakker bespaart water en energie

    Energy Technology Data Exchange (ETDEWEB)

    Van Gool, J. (ed.)

    2003-11-01

    A pastry factory (Verkade in Zaandam, Netherlands) produces 27,000 ton of cookies and biscuits, using 2.2 million m{sup 3} natural gas, 6.7 million kWh and 67,000 m{sup 3} water. By means of new cooling systems a considerable amount of energy and water is saved. [Dutch] Verkade in Zaandam produceert jaarlijks 27.000 ton biscuit, waarvoor 2,2 miljoen m{sup 3} gas, 6,7 miljoen kilowattuur en 67.000 m{sup 3} water nodig is. Dankzij vernieuwde koelsystemen is het water- en energieverbruik flink gedaald.

  3. Air Force Civil Engineer Center Management of Energy Savings Performance Contracts Needs Improvement

    Science.gov (United States)

    2016-05-04

    billions in energy costs, promote energy independence, and create tens of thousands of construction sector jobs. Federal Acquisition Regulation ESPC...infrastructure to reduce energy demand, increase renewable energy , and enhance the power resiliency of installations. Additional energy guidance provided...Force Civil Engineer Center Management of Energy Savings Performance Contracts Needs Improvement M A Y 4 , 2 0 1 6 Report No. DODIG-2016-087 Mission

  4. Validating Savings Claims of Cold Climate Zero Energy Ready Homes

    Energy Technology Data Exchange (ETDEWEB)

    Williamson, J. [Consortium for Advanced Residential Buildings, Norwalk, CT (United States); Puttagunta, S. [Consortium for Advanced Residential Buildings, Norwalk, CT (United States)

    2015-06-05

    This study was intended to validate actual performance of three ZERHs in the Northeast to energy models created in REM/Rate v14.5 (one of the certified software programs used to generate a HERS Index) and the National Renewable Energy Laboratory’s Building Energy Optimization (BEopt™) v2.3 E+ (a more sophisticated hourly energy simulation software). This report details the validation methods used to analyze energy consumption at each home.

  5. Thermal energy systems design and analysis

    CERN Document Server

    Penoncello, Steven G

    2015-01-01

    IntroductionThermal Energy Systems Design and AnalysisSoftwareThermal Energy System TopicsUnits and Unit SystemsThermophysical PropertiesEngineering DesignEngineering EconomicsIntroductionCommon Engineering Economics NomenclatureEconomic Analysis Tool: The Cash Flow DiagramTime Value of MoneyTime Value of Money ExamplesUsing Software to Calculate Interest FactorsEconomic Decision MakingDepreciation and TaxesProblemsAnalysis of Thermal Energy SystemsIntroductionNomenclatureThermophysical Properties of SubstancesSuggested Thermal Energy Systems Analysis ProcedureConserved and Balanced QuantitiesConservation of MassConservation of Energy (The First Law of Thermodynamics)Entropy Balance (The Second Law of Thermodynamics)Exergy Balance: The Combined LawEnergy and Exergy Analysis of Thermal Energy CyclesDetailed Analysis of Thermal Energy CyclesProblemsFluid Transport in Thermal Energy SystemsIntroductionPiping and Tubing StandardsFluid Flow FundamentalsValves and FittingsDesign and Analysis of Pipe NetworksEconomi...

  6. Technical Support Document: Strategies for 50% Energy Savings in Large Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Leach, M.; Lobato, C.; Hirsch, A.; Pless, S.; Torcellini, P.

    2010-09-01

    This Technical Support Document (TSD) documents technical analysis that informs design guidance for designing and constructing large office buildings that achieve 50% net site energy savings over baseline buildings defined by minimal compliance with respect to ANSI/ASHRAE/IESNA Standard 90.1-2004. This report also represents a step toward developing a methodology for using energy modeling in the design process to achieve aggressive energy savings targets. This report documents the modeling and analysis methods used to identify design recommendations for six climate zones that capture the range of U.S. climate variability; demonstrates how energy savings change between ASHRAE Standard 90.1-2007 and Standard 90.1-2004 to determine baseline energy use; uses a four-story 'low-rise' prototype to analyze the effect of building aspect ratio on energy use intensity; explores comparisons between baseline and low-energy building energy use for alternate energy metrics (net source energy, energy emissions, and energy cost); and examines the extent to which glass curtain construction limits achieve energy savings by using a 12-story 'high-rise' prototype.

  7. Study on the optimum PCM melting temperature for energy savings in residential buildings worldwide

    Science.gov (United States)

    Saffari, M.; de Gracia, A.; Fernández, C.; Zsembinszki, G.; Cabeza, L. F.

    2017-10-01

    To maintain comfort conditions in residential buildings along a full year period, the use of active systems is generally required to either supply heating or cooling. The heating and cooling demands strongly depend on the climatic conditions, type of building and occupants’ behaviour. The overall annual energy consumption of the building can be reduced by the use of renewable energy sources and/or passive systems. The use of phase change materials (PCM) as passive systems in buildings enhances the thermal mass of the envelope, and reduces the indoor temperature fluctuations. As a consequence, the overall energy consumption of the building is generally lower as compared to the case when no PCM systems are used. The selection of the PCM melting temperature is a key issue to reduce the energy consumption of the buildings. The main focus of this study is to determine the optimum PCM melting temperature for passive heating and cooling according to different weather conditions. To achieve that, numerical simulations were carried out using EnergyPlus v8.4 coupled with GenOpt® v3.1.1 (a generic optimization software). A multi-family residential apartment was selected from ASHRAE Standard 90.1- 2013 prototype building model, and different climate conditions were considered to determine the optimum melting temperature (in the range from 20ºC to 26ºC) of the PCM contained in gypsum panels. The results confirm that the optimum melting temperature of the PCM strongly depends on the climatic conditions. In general, in cooling dominant climates the optimum PCM temperature is around 26ºC, while in heating dominant climates it is around 20ºC. Furthermore, the results show that an adequate selection of the PCM as passive system in building envelope can provide important energy savings for both heating dominant and cooling dominant regions.

  8. Energy Saving in Data Processing and Communication Systems

    Directory of Open Access Journals (Sweden)

    Giuseppe Iazeolla

    2014-01-01

    Full Text Available The power management of ICT systems, that is, data processing (Dp and telecommunication (Tlc systems, is becoming a relevant problem in economical terms. Dp systems totalize millions of servers and associated subsystems (processors, monitors, storage devices, etc. all over the world that need to be electrically powered. Dp systems are also used in the government of Tlc systems, which, besides requiring Dp electrical power, also require Tlc-specific power, both for mobile networks (with their cell-phone towers and associated subsystems: base stations, subscriber stations, switching nodes, etc. and for wired networks (with their routers, gateways, switches, etc.. ICT research is thus expected to investigate into methods to reduce Dp- and Tlc-specific power consumption. However, saving power may turn into waste of performance, in other words, into waste of ICT quality of service (QoS. This paper investigates the Dp and Tlc power management policies that look at compromises between power saving and QoS.

  9. Performing impact evaluations in industrial retrofit: The Energy Savings Plan Program

    Energy Technology Data Exchange (ETDEWEB)

    Riewer, S. [USDOE Bonneville Power Administration, Portland, OR (United States); Spanner, G.E. [Pacific Northwest Lab., Richland, WA (United States)

    1991-08-01

    The Energy Savings Plan (ESP) is Bonneville Power Administration`s retrofit program for the industrial sector. The program pays incentives for energy conservation measures involving electrical energy efficiency improvements in manufacturing, processing, and refining industries. This paper will describe the ESP program, recount the techniques selected to evaluate the retrofits, and report the findings from five ESP project impact evaluations completed to date. The impact evaluations provide a framework for assessing the energy saving achieved by the provides implemented under the ESP. In addition to energy savings, the evaluations assess process changes, net utility impacts, levelized costs, and ``free ridership.`` The five ESP projects evaluated include: a waste heat recovery system for a food processing blancher, an energy management control system used to upgrade refrigeration, a variable speed drive for a fan motor in a lumber mill, a sludge screw press for waste water treatment, and replacement of rod anodes with blades anodes in mercury cells in an electrochemical plant.

  10. Energy Savings Potential of Flexible and Adaptive HVAC Distribution Systems for Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Loftness, Vivian; Brahme, Rohini; Mondazzi, Michelle; Vineyard, Edward; MacDonald, Michael

    2002-06-01

    It has been understood by architects and engineers that office buildings with easily re-configurable space and flexible mechanical and electrical systems are able to provide comfort that increases worker productivity while using less energy. Raised floors are an example of how fresh air, thermal conditioning, lighting needs, and network access can be delivered in a flexible manner that is not ''embedded'' within the structure. What are not yet documented is how well these systems perform and how much energy they can save. This area is being investigated in phased projects of the 21st Century Research Program of the Air-conditioning and Refrigeration Technology Institute. For the initial project, research teams at the Center for Building Performance and Diagnostics, Pittsburgh, Pennsylvania, and Oak Ridge National Laboratory, Oak Ridge, Tennessee, documented the diversity, performance, and incidence of flexible and adaptive HVAC systems. Information was gathered worldwide from journal and conference articles, case studies, manufactured products and assemblies, and interviews with design professionals. Their report thoroughly describes the variety of system types along with the various design alternatives observed for plenums, diffusers, individual control, and system integration. Many of the systems are illustrated in the report and the authors provide quantitative and qualitative comparisons. Among conclusions regarding key design issues, and barriers to widespread adoption, the authors state that flexible and adaptive HVAC systems, such as underfloor air, perform as well if not better than ceiling-based systems. Leading engineers have become active proponents after their first experience, which is resulting in these flexible and adaptive HVAC systems approaching 10 percent of the new construction market. To encourage adoption of this technology that improves thermal comfort and indoor air quality, follow-on work is required to further document

  11. Uncertainty in Odyssee indicators and energy savings. Development of a methodology and first results

    Energy Technology Data Exchange (ETDEWEB)

    Boonekamp, P.G.M.; Gerdes, J. [ECN Policy Studies, Petten (Netherlands); Faberi, S. [Institute of Studies for the Integration of Systems ISIS, Rome (Italy)

    2013-12-15

    The ODYSSEE database on energy efficiency indicators (www.odyssee-indicators.org) has been set up to enable the monitoring and evaluation of realised energy efficiency improvements and related energy savings. The database covers the 27 EU countries as well as Norway and Croatia. Energy indicators that relate energy consumption to a physical output (ton of steel), a performance (person-km driven per car) or the number of energy using devices (refrigerators) can show the increase in energy efficiency realised, and the amount of energy saved. By aggregating indicators, Odyssee calculates energy efficiency indices by sector and for the whole economy (so-called ODEX), in order to evaluate overall energy efficiency progress. This work contributes to the growing need for quantitative monitoring and evaluation of the impacts of energy policies and measures, both at the EU and national level, e.g. due to the Energy Service Directive. Because of the central role of Odyssee indicators in policy evaluations it becomes more important to know how reliable the Odyssee figures are, or in other words, what is the uncertainty margin for the indicator values and the related savings. This report presents a first analysis of uncertainty margins in the indicators and savings figures. The work builds on earlier work in the preceding Odyssee project with regard to the quality of input data used in Odyssee.

  12. Expert Meeting Report. Energy Savings You Can Bank On

    Energy Technology Data Exchange (ETDEWEB)

    Berman, Mark [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Springer, Jeremy [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Smith, Pepper [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Porse, Erik [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States)

    2013-02-01

    In October 2011, ARBI organized and conducted an Experts’ Meeting on the topic of performance guarantees and financing vehicles for Energy Efficiency Upgrades. The meeting brought together technical, policy, and financial experts, including researchers, experienced installation contractors, and innovative energy business leaders, in order to discuss the opportunities and challenges for the energy efficiency upgrade industry to increase market uptake of Home Energy Upgrades (HEUs) through innovative offerings, such as performance guarantees.

  13. Innovative Phase Change Approach for Significant Energy Savings

    Science.gov (United States)

    2016-09-01

    that will help approach the target payback period include obtaining PCM with higher specific thermal storage, which will reduce the unit footprint and...2016 24 payback period include obtaining PCM with higher specific thermal storage, which will reduce the unit footprint and cost. 7. Ease of Use...the PCM, we used the Q18, which is made of vegetable oils, has melting range extends from 14°C (57.2°F) to 22°C (71.60°F) with a melting point at 18°C

  14. Energy flow and thermal comfort in buildings

    DEFF Research Database (Denmark)

    Le Dreau, Jerome

    insulated buildings (R > 5 m2.K/W). In case of single-storey building with a low level of insulation, the effectiveness of radiant terminals is lower due to the larger back losses, and an air-based terminal might be more energy-efficient than a radiant terminal (in terms of delivered energy). Regarding...... is based on both radiation and convection. Radiant terminals have the advantage of making use of low grade sources (i.e. low temperature heating and high temperature cooling), thus decreasing the primary energy consumption of buildings. But there is a lack of knowledge on the heat transfer from...... beam. The higher the air change rate and the warmer the outdoor air, the larger the savings achieved with a radiant cooling terminals. Therefore radiant terminals have a large potential of energy savings for buildings with high ventilation rates (e.g. shop, train station, industrial storage). Among...

  15. DSM energy saving pilot project report. Furniture Plant Teika, Riga, Latvia

    Energy Technology Data Exchange (ETDEWEB)

    Ananevski, V.; Kalejs, M.; Hercogs, J.; Blumbergs, U.

    1995-07-01

    The purpose of this pilot project was to carry out energy audit into the furniture plant TEIKA and energy saving measures. Another aim was to transfer the Danish know how and experience obtained through the Danish effort in Latvian industries consumers. Therefore great attention is paid to energy mapping in order to show possibilities of the Danish methodisms. This report is a part of the Joint Latvian - Danish Project Demand Side Management and Energy Saving. It is a results of collaborative efforts between a Latvian team, consisting of the specialists from Latvenergo and on the other hand a Danish team, which was represented by the Danish Power Consult company NESA. (EG)

  16. Performance analysis of TCP traffic and its influence on ONU's energy saving in energy efficient TDM-PON

    Science.gov (United States)

    Alaelddin, Fuad Yousif Mohammed; Newaz, S. H. Shah; Lee, Joohyung; Uddin, Mohammad Rakib; Lee, Gyu Myoung; Choi, Jun Kyun

    2015-12-01

    The majority of the traffic over the Internet is TCP based, which is very sensitive to packet loss and delay. Existing research efforts in TDM-Passive Optical Networks (TDM-PONs) mostly evaluate energy saving and traffic delay performances under different energy saving solutions. However, to the best of our knowledge, how energy saving mechanisms could affect TCP traffic performance in TDM-PONs has hardly been studied. In this paper, by means of our state-of-art OPNET Modular based TDM-PON simulator, we evaluate TCP traffic delay, throughput, and Optical Network Unit (ONU) energy consumption performances in a TDM-PON where energy saving mechanisms are employed in ONUs. Here, we study the performances under commonly used energy saving mechanisms defined in standards for TDM-PONs: cyclic sleep and doze mode. In cyclic sleep mode, we evaluate the performances under two well-known sleep interval length deciding algorithms (i.e. fixed sleep interval (FSI) and exponential sleep interval deciding (ESID)) that an OLT uses to decide sleep interval lengths for an ONU. Findings in this paper put forward the strong relationship among TCP traffic delay, throughput and ONU energy consumption under different sleep interval lengths. Moreover, we reveal that under high TCP traffic, both FSI and ESID will end up showing similar delay, energy and throughput performance. Our findings also show that doze mode can offer better TCP throughput and delay performance at the price of consuming more energy than cyclic sleep mode. In addition, our results provide a glimpse on understanding at what point doze mode becomes futile in improving energy saving of an ONU under TCP traffic. Furthermore, in this paper, we highlight important research issues that should be studied in future research to maximize energy saving in TDM-PONs while meeting traffic Quality of Service requirements.

  17. Thermal comfort

    CSIR Research Space (South Africa)

    Osburn, L

    2010-01-01

    Full Text Available wider range of temperature limits, saving energy while still satisfying the majority of building occupants. It is also noted that thermal comfort varies significantly between individuals and it is generally not possible to provide a thermal environment...

  18. Energy Savings from GSA's National Deep Retrofit Program

    Energy Technology Data Exchange (ETDEWEB)

    Shonder, John A [ORNL

    2014-09-01

    Under its National Deep Energy Retrofit (NDER) program, the U.S. General Services Administration (GSA) awarded 10 ESPC projects with the objectives of using innovative technologies and renewable energy technologies, and moving buildings toward net zero energy consumption. This report analyzes data on energy savings from the 10 NDER projects, and compares them with the savings of a sample of other recently awarded Federal ESPC projects. It is shown that by emphasizing the need for deeper energy savings, and by the establishment of a central Project Management Office (PMO) to provide authoritative contracting, technical and pricing assistance, the NDER projects achieved an average level of savings more than twice that of the other Federal ESPC projects. The level of savings achieved in each project seems to be dependent more on the availability of ECMs at the site than on energy price, energy cost per square foot, pre-retrofit EUI or the length of the contract term. This suggests that GSA can achieve similar results in a wide variety of building

  19. Improving Ventilation and Saving Energy: Final Report on Indoor Environmental Quality and Energy Monitoring in Sixteen Relocatable Classrooms

    Energy Technology Data Exchange (ETDEWEB)

    Apte, Michael G.; Norman, Bourassa; Faulkner, David; Hodgson, Alfred T.; Hotchi, Toshfumi; Spears, Michael; Sullivan, Douglas P.; Wang, Duo

    2008-04-04

    effective removal of volatile organic compounds and aldehydes, on average lowering the concentrations by 57 percent relative to the levels in the 10 SEER classrooms. The average IHPAC to 10 SEER formaldehyde ratio was about 67 percent, indicating only a 33 percent reduction of this compound in indoor air. The IHPAC thermal control system provided less variability in occupied classroom temperature than the 10 SEER thermostats. The average room temperatures in all seasons tended to be slightly lower in the IHPAC classrooms, often below the lower limit of the ASHRAE 55 thermal comfort band. State-wide and national energy modeling provided conservative estimates of potential energy savings by use of the IHPAC system that would provide payback a the range of time far lower than the lifetime of the equipment. Assuming electricity costs of $0.15/kWh, the perclassroom range of savings is from about $85 to $195 per year in California, and about $89 to $250 per year in the U.S., depending upon the city. These modelsdid not include the non-energy benefits to the classrooms including better air quality and acoustic conditions that could lead to improved health and learning in school. Market connection efforts that were part of the study give all indication that this has been a very successful project. The successes include the specification of the IHPAC equipment in the CHPS portable classroom standards, the release of a commercial product based on the standards that is now being installed in schools around the U.S., and the fact that a public utility company is currently considering the addition of the technology to its customer incentive program. These successes indicate that the IHPAC may reach its potential to improve ventilation and save energy in classrooms.

  20. The potential and need for energy saving in standard family detached and semi-detached wooden houses in arctic Greenland

    DEFF Research Database (Denmark)

    Bjarløv, Søren Peter; Vladyková, Petra

    2011-01-01

    The paper gives an account of the potential and need for energy saving in standard family detached and semi-detached wooden houses in Greenland. It is based on studies of house construction compared with Building Regulation requirements and the spread of buildings over time. In the climatic...... (type 18D). Temperature, relative humidity and air tightness were measured, and thermal bridges were determined from drawings, visual inspection, and by using a thermal camera. The findings show a current energy consumption of up to 378 kWh/(m²•a) for heating, poor air tightness, a large number...... to approximately half of the housing stock without changing the architectural expression or having to relocate the occupants during the renovation....

  1. Ringkøbing-Skjern energy atlas for analysis of heat saving potentials in building stock

    DEFF Research Database (Denmark)

    Petrovic, Stefan; Karlsson, Kenneth Bernard

    2016-01-01

    such drastic change of municipality's energy system. For that purpose, GIS-based Ringkøbing-Skjern Energy Atlas has been developed. The present paper utilises Ringkøbing-Skjern Energy Atlas together with the Heating Model to calculate potentials and costs of heat saving measures.The results show......Ringkøbing-Skjern municipality aims to be 100% self-sufficient in renewable energy supply starting from 2020. It is expected that the building sector will contribute by reducing energy demand by 25-50%.Technical, economic, environmental and geographical aspects need to be considered when analysing...... that the reduction of heating demand by 25% and 35% can be achieved at the annuitized full cost lower than 1.7 and 2 DKK/kWh, respectively. The results also show that significant heat saving potential lies in farmhouses and detached houses as well as in buildings built before 1950. Over 75% of very cheap heat saving...

  2. Energy-saving occupant behaviours in offices: change strategies.

    OpenAIRE

    Mulville, M.; Jones, K.; Huebner, G.; Powell-Greig, J.

    2016-01-01

    As regulated energy consumption in buildings is reduced; the proportional importance of unregulated energy consumption increases. Reducing unregulated energy use in the commercial office requires an understanding of the factors that influence workplace behaviour. To date these factors have been assumed to be similar to those that influence behaviour in the home. However, the social dynamics of the workplace are different to that in the home. This study examined the degree to which theories of...

  3. Energy-saving Occupant Behaviour in Offices: Change Strategies

    OpenAIRE

    Mulville, Mark; Jones, Keith; Huebner, Gesche; Powell-Grieg, Joanne

    2016-01-01

    As regulated energy consumption in buildings is reduced, the proportional importance of unregulated energy consumption increases. Reducing unregulated energy use in the commercial office requires an understanding of the factors that influence workplace behaviour. To date these factors have been assumed to be similar to those that influence behaviour in the home. However, the social dynamics of the workplace are different to those in the home. This study examines the degree to which theories o...

  4. Energy-saving occupant behaviours in offices: change strategies

    OpenAIRE

    Mulville, M.; Jones, K.; Huebner, G.; Powell-Greig, J.

    2016-01-01

    As regulated energy consumption in buildings is reduced, the proportional importance of unregulated energy consumption increases. Reducing unregulated energy use in the commercial office requires an understanding of the factors that influence workplace behaviour. To date these factors have been assumed to be similar to those that influence behaviour in the home. However, the social dynamics of the workplace are different to those in the home. This study examines the degree to which theories o...

  5. A New Method to Energy Saving in a Micro Grid

    Directory of Open Access Journals (Sweden)

    Andrea Vallati

    2015-10-01

    Full Text Available Optimization of energy production systems is a relevant issue that must be considered in order to follow the fossil fuels consumption reduction policies and CO2 emission regulation. Increasing electricity production from renewable resources (e.g., photovoltaic systems and wind farms is desirable but its unpredictability is a cause of problems for the main grid stability. A system with multiple energy sources represents an efficient solution, by realizing an interface among renewable energy sources, energy storage systems, and conventional power generators. Direct consequences of multi-energy systems are a wider energy flexibility and benefits for the electric grid, the purpose of this paper is to propose the best technology combination for electricity generation from a mix of renewable energy resources to satisfy the electrical needs. The paper identifies the optimal off-grid option and compares this with conventional grid extension, through the use of HOMER software. The solution obtained shows that a hybrid combination of renewable energy generators at an off-grid location can be a cost-effective alternative to grid extension and it is sustainable, techno-economically viable, and environmentally sound. The results show how this innovative energetic approach can provide a cost reduction in power supply and energy fees of 40% and 25%, respectively, and CO2 emission decrease attained around 18%. Furthermore, the multi-energy system taken as the case study has been optimized through the utilization of three different type of energy storage (Pb-Ac batteries, flywheels, and micro—Compressed Air Energy Storage (C.A.E.S..

  6. The challenge to UK energy policy: An ageing population perspective on energy saving measures and consumption

    Energy Technology Data Exchange (ETDEWEB)

    Hamza, Neveen, E-mail: n.hamza@ncl.ac.u [School of Architecture, Planning and Landscape Newcastle University, NE1 7RU (United Kingdom); Gilroy, Rose [School of Architecture, Planning and Landscape Newcastle University, NE1 7RU (United Kingdom)

    2011-02-15

    With a focus on the residential sector, this paper explores the likelihood of the UK government meeting its energy targets. The paper contends that energy policy needs to take into account the interplay of four major factors: an ageing population of increasing diversity; a cultural inclination for older housing much of which is thermally inefficient; levels of fuel poverty; and the inexorable rise of consumer spending on leisure related services and goods. Decisions made by older households (both the poorer and the better off) may be critical to the success of energy policy. Among the better off the changing expectations of the baby boomers, with their predilection for consumption and travel, may have particular impact. The paper concludes that much of the reduction in carbon footprint made by older people's choices in heating and insulation may be offset, not only by increasing domestic thermal comfort, but also potentially by increasing consumables in the home and other consumer lifestyle choices. What could be achieved at best, may be a shift in energy mix. - Research highlights: {yields} An aging society in the UK will not lead to reduction in energy consumption. {yields} Physical ability, housing condition, cultural habits and energy poverty undermine policy. {yields} Rise of home entertainment and consumerism 'Afluenza' increase energy consumption.

  7. Low-cost, highly transparent flexible low-e coating film to enable electrochromic windows with increased energy savings

    Energy Technology Data Exchange (ETDEWEB)

    Berland, Brian [ITN Energy Systems, Inc., Littleton, CO (United States); Hollingsworth, Russell [ITN Energy Systems, Inc., Littleton, CO (United States)

    2015-03-31

    silica and a transparent conductive oxide demonstrated 90% visible transmission with high thermal infrared reflectivity characteristic of conventional low-e coatings. A slightly more complex stack provided high solar infrared reflection without sacrificing visible transmission or thermal infrared reflection. Successful completion of the effort produced a prototype integrated low-e, dynamic window film with characterized energy saving potential. Cost modeling for the passive bi-layer, low-e film projects a manufacturing cost of ~$0.50/ft2 for a plant with 10M ft2/yr capacity. The novel thin film processes developed here enable high deposition rate (low cost), optical quality oxide coatings at low temperatures. When combined with engineered materials, ITN’s coating will result in low-cost, low-e films that reflect a high degree of infrared radiation without substantially reducing the visible transmission. The resultant window film will improve the U-value and achieve SHGC improvements over bare glass. The new low-e coating will be particularly attractive when combined with an electrochromic film. Low-e coating design guided by energy savings modeling allows customization of the product for different climate zones.

  8. Heat Loss Experiments: Teach Energy Savings with Cardboard "House"

    Science.gov (United States)

    Roman, Harry T.

    2011-01-01

    Using two cardboard boxes, a light bulb socket, light bulbs of varying wattage, a thermometer, and some insulation, students can learn some interesting lessons about how heat loss occurs in homes. This article describes practical experiments that work well on units related to energy, sustainable energy, renewables, engineering, and construction.…

  9. Energy Saving for Belt Conveyors by Speed Control

    NARCIS (Netherlands)

    He, D.

    2017-01-01

    Belt conveyors are widely used in bulk solids handling and conveying systems. Considering the extensive use of belt conveyors, their operations involve a large amount of energy. Taking the relevant economic and social challenges into account, there is a strong demand for lowering the energy

  10. Shared Savings Contracting for Reducing Energy Costs of Defense Facilities.

    Science.gov (United States)

    1983-01-01

    Program Evaluation for Resource Management," October 17, 1972. BUILDING ENERGY EFFICIENCY D. C. Solar Task Force, "Thirty Five Steps - Making...Conservation and Solar Work in the District of Columbia," Washington, D. C., 1982. National Institute of Building Sciences, " Building Energy Efficiency Project

  11. The Association between Energy Saving and Guest Comfort in ...

    African Journals Online (AJOL)

    This research adopted a multiple case study approach, in which eight guesthouses were selected for in depth study. A questionnaire, observation checklist, energy meters and a lux meter were used for data collection. The results show that the national grid, petroleum, solar and gas were the primary energy sources used in ...

  12. Expert Meeting Report: Energy Savings You Can Bank On

    Energy Technology Data Exchange (ETDEWEB)

    Beman, M.; Springer, J.; Smith, P.; Porse, E.

    2013-02-01

    In October 2011, ARBI organized and conducted an Experts' Meeting on the topic of performance guarantees and financing vehicles for Energy Efficiency Upgrades. The meeting brought together technical, policy, and financial experts, including researchers, experienced installation contractors, and innovative energy business leaders, in order to discuss the opportunities and challenges for the energy efficiency upgrade industry to increase market uptake of Home Energy Upgrades (HEUs) through innovative offerings, such as performance guarantees. The meeting had several primary goals. First, it sought to understand how other industries have developed successful models for financing renewable energy installations while providing performance guarantees. This has been most recently demonstrated by the solar leasing industry. Second, the meeting explored the applicability of such business models to the energy efficiency upgrade industry. Third, the meeting sought to identify technical impediments to performance guarantees for energy efficiency retrofits. Fourth, the meeting sought to provide a common framework for these goals within the context of current financing mechanisms for energy efficiency upgrades.

  13. Traffic-aware Elastic Optical Networks to leverage Energy Savings

    DEFF Research Database (Denmark)

    Turus, Ioan; Fagertun, Anna Manolova; Dittmann, Lars

    2014-01-01

    Because of the static nature of the deployed optical networks, large energy wastage is experienced today in production networks such as Telecom networks . With power-adaptive optical interfaces and suitable grooming procedures, we propose the design of more energy efficient transport networks. Op...

  14. Heat pump for comfort, with added energy savings

    NARCIS (Netherlands)

    Cauberg, H.; Van de Dobbelsteen, A.; Van der Spoel, W.; Van de Graaf, A.

    2005-01-01

    The high-efficiency central heating boiler is about to reach the limits of its potential, so innovative insulation and other energy efficiency solutions are required, even though energy consumption in the Netherlands per household has dropped by 70% since 1986. Now that houses and offices are being

  15. A simple tool for estimating city-wide annual electrical energy savings from cooler surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Pomerantz, Melvin; Rosado, Pablo J.; Levinson, Ronnen

    2015-12-01

    We present a simple method to estimate the maximum possible electrical energy saving that might be achieved by increasing the albedo of surfaces in a large city. We restrict this to the “indirect effect”, the cooling of outside air that lessens the demand for air conditioning (AC). Given the power demand of the electric utilities and data about the city, we can use a single linear equation to estimate the maximum savings. For example, the result for an albedo change of 0.2 of pavements in a typical warm city in California, such as Sacramento, is that the saving is less than about 2 kWh per m2 per year. This may help decision makers choose which heat island mitigation techniques are economical from an energy-saving perspective.

  16. OPTIMAL AND QAUSI-ENERGY-SAVING CONTROL POSATION VARIABLE FREQUENCY ASYNCHRONOUS MOTORS

    Directory of Open Access Journals (Sweden)

    V.A. Volkov

    2016-07-01

    Using the method of the calculus of variations to offer optimal and quasi-optimal types of energy-saving variable frequency control the position of the induction motor (FCIM, which provide basic minimization of electromagnetic energy loss (BEEL of the engine when developing an arbitrary value of a small displacement of the shaft in the required time. Obtained for the proposed types of energy-saving control analytical dependencies to change the position and speed of the time, as well as to determine the maximum value of the engine speed. Calculations of the time change process: position, speed, electromagnetic torque, modulus of the generalized vector of the stator current, general electromagnetic power loss and engine BEEL – relevant proposals and quasi optimal energy-saving type of control. A comparison between a proposed and known (parabolic and linear dependence of the velocity on the time change types of energy-saving position control with small movements FCIM. Proposed optimal and quasi-optimal types of energy-saving position control are recommended for use in positional variable frequency asynchronous electric drive (for example, lifting-transport mechanisms and rotary platforms, urban and railway electric transport, etc...

  17. Energy Efficiency Improvement and Cost Saving Opportunities for the Pharmaceutical Industry. An ENERGY STAR Guide for Energy and Plant Managers

    Energy Technology Data Exchange (ETDEWEB)

    Galitsky, Christina; Galitsky, Christina; Chang, Sheng-chieh; Worrell, Ernst; Masanet, Eric

    2008-03-01

    The U.S. pharmaceutical industry consumes almost $1 billion in energy annually. Energy efficiency improvement is an important way to reduce these costs and to increase predictable earnings, especially in times of high energy price volatility. There are a variety of opportunities available at individual plants in the U.S. pharmaceutical industry to reduce energy consumption in a cost-effective manner. This Energy Guide discusses energy efficiency practices and energy efficient technologies that can be implemented at the component, process, system, and organizational levels. A discussion of the trends, structure, and energy consumption characteristics of the U.S. pharmaceutical industry is provided along with a description of the major process steps in the pharmaceutical manufacturing process. Expected savings in energy and energy-related costs are given for many energy efficiency measures, based on case study data from real-world applications in pharmaceutical and related facilities worldwide. Typical measure payback periods and references to further information in the technical literature are also provided, when available. The information in this Energy Guide is intended to help energy and plant managers reduce energy consumption in a cost-effective manner while meeting regulatory requirements and maintaining the quality of products manufactured. At individual plants, further research on the economics of the measures?as well as their applicability to different production practices?is needed to assess potential implementation of selected technologies.

  18. Keys to the House: Unlocking Residential Savings With Program Models for Home Energy Upgrades

    Energy Technology Data Exchange (ETDEWEB)

    Grevatt, Jim [Energy Futures Group (United States); Hoffman, Ian [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Hoffmeyer, Dale [US Department of Energy, Washington, DC (United States)

    2017-07-05

    After more than 40 years of effort, energy efficiency program administrators and associated contractors still find it challenging to penetrate the home retrofit market, especially at levels commensurate with state and federal goals for energy savings and emissions reductions. Residential retrofit programs further have not coalesced around a reliably successful model. They still vary in design, implementation and performance, and they remain among the more difficult and costly options for acquiring savings in the residential sector. If programs are to contribute fully to meeting resource and policy objectives, administrators need to understand what program elements are key to acquiring residential savings as cost effectively as possible. To that end, the U.S. Department of Energy (DOE) sponsored a comprehensive review and analysis of home energy upgrade programs with proven track records, focusing on those with robustly verified savings and constituting good examples for replication. The study team reviewed evaluations for the period 2010 to 2014 for 134 programs that are funded by customers of investor-owned utilities. All are programs that promote multi-measure retrofits or major system upgrades. We paid particular attention to useful design and implementation features, costs, and savings for nearly 30 programs with rigorous evaluations of performance. This meta-analysis describes program models and implementation strategies for (1) direct install retrofits; (2) heating, ventilating and air-conditioning (HVAC) replacement and early retirement; and (3) comprehensive, whole-home retrofits. We analyze costs and impacts of these program models, in terms of both energy savings and emissions avoided. These program models can be useful guides as states consider expanding their strategies for acquiring energy savings as a resource and for emissions reductions. We also discuss the challenges of using evaluations to create program models that can be confidently applied in

  19. Max Tech Appliance Design: Potential for Maximizing U.S. Energy Savings through Standards

    Energy Technology Data Exchange (ETDEWEB)

    Garbesi, Karina; Desroches, Louis-Benoit; Bolduc, Christopher; Burch, Gabriel; Hosseinzadeh, Griffin; Saltiel, Seth

    2011-05-06

    This study surveyed the technical potential for efficiency improvements in 150 categories of appliances and equipment representing 33 quads of primary energy use across the US economy in 2010 and (1) documented efficient product designs, (2) identified the most promising cross-cutting strategies, and (3) ranked national energy savings potential by end use. Savings were estimated using a method modeled after US Department of Energy priority-setting reports - simplified versions of the full technical and economic analyses performed for rulemakings. This study demonstrates that large savings are possible by replacing products at the end-of-life with ultra-efficient models that use existing technology. Replacing the 50 top energy-saving end-uses (constituting 30 quads of primary energy consumption in 2010) with today's best-on-market equivalents would save {approx}200 quads of US primary energy over 30 years (25% of consumption anticipated there from). For the 29 products for maximum feasible savings potential could be estimated, the savings were twice as high. These results demonstrate that pushing ultra-efficient products to market could significantly escalate carbon emission reductions and is a viable strategy for sustaining large emissions reductions through standards. The results of this analysis were used by DOE for new coverage prioritization, to identify key opportunities for product prototyping and market development, and will leverage future standards rulemakings by identifying the full scope of maximum feasible technology options. High leverage products include advances lighting systems, HVAC, and televisions. High leverage technologies include electronic lighting, heat pumps, variable speed motors, and a host of controls-related technologies.

  20. Risk control in energy saving projects; Control de riesgo en los proyectos de ahorro de energia

    Energy Technology Data Exchange (ETDEWEB)

    Mills, Evan [Lawrence Berkeley National Laboratory, CA (United States)

    2005-10-15

    Since one of the restrictive problems when investing in energy saving is the uncertainty of obtaining the planed savings, a technique in the risk handling for energy efficiency projects, called Insurance for the Energy Saving (IES) is presented. IES economically stimulates those who implement projects for energy saving so they go beyond the normal measures and really obtain significant saving levels, thus contributing to the fulfillment of national objectives in energy saving. In order to reduce the risk of low performance in energy caused by saving projects there exist the international performance measurement and the protocol of investment (IMPVP) as well as diagnoses and starting processes, whereas in order to transfer the financial risk that a saving project represents, mechanisms such as FDIC insurance, conversion of the debt in values, Saving's Guarantees, Performance Bonuses or Guarantee Bonuses and Insurances for Energy Saving can be of great help. This article deals on the IES insurance policies, their loss control management, successful cases, benefits, particular advantages, place in the market and refers argued insurance exceptions and perception surveys. [Spanish] Dado que uno de los problemas restrictivos a la hora de invertir en el ahorro de energia es la incertidumbre de obtener los ahorros proyectados, se presenta una tecnica en el manejo del riesgo para proyectos de eficiencia energetica llamada Seguro para el Ahorro de Energia (SAE). SAE estimula financieramente a quienes implementan proyectos para el ahorro de energia con el fin de que vayan mas alla de las medidas normales y consigan niveles significativos de ahorro, contribuyendo asi al cumplimiento de objetivos nacionales de ahorro energetico. Para reducir el riesgo de bajo desempeno de energia provocados por proyectos de ahorro existe la medicion del desempeno internacional y el protocolo de inversion (IMPVP) asi como diagnosticos y procesos de arranque, mientras que para transferir el

  1. Analyzing the Life Cycle Energy Savings of DOE Supported Buildings Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Cort, Katherine A.; Hostick, Donna J.; Dirks, James A.; Elliott, Douglas B.

    2009-08-31

    This report examines the factors that would potentially help determine an appropriate analytical timeframe for measuring the U.S. Department of Energy's Building Technology (BT) benefits and presents a summary-level analysis of the life cycle savings for BT’s Commercial Buildings Integration (CBI) R&D program. The energy savings for three hypothetical building designs are projected over a 100-year period using Building Energy Analysis and Modeling System (BEAMS) to illustrate the resulting energy and carbon savings associated with the hypothetical aging buildings. The report identifies the tasks required to develop a long-term analytical and modeling framework, and discusses the potential analytical gains and losses by extending an analysis into the “long-term.”

  2. Achieving Energy Savings in Municipal Construction in Long Beach California

    Energy Technology Data Exchange (ETDEWEB)

    None

    2013-03-01

    Long Beach Gas and Oil (LBGO), the public gas utility in Long Beach, California, partnered with the U.S. Department of Energy (DOE) to develop and implement solutions to build a new, low-energy modular office building that is at least 50% below requirements set by Energy Standard 90.1-2007 of the American Society of Heating, Refrigerating, and Air-conditioning Engineers (ASHRAE), the American National Standards Institute (ANSI), and the Illuminating Engineering Society of America (IESNA) as part of DOE’s Commercial Building Partnerships (CBP) program. The LBGO building, which demonstrates that modular construction can be very energy efficient, is expected to exceed the ASHRAE baseline by about 45%.

  3. Commercial Building Partnership General Merchandise Energy Savings Overview

    Energy Technology Data Exchange (ETDEWEB)

    None

    2013-03-01

    The Commercial Building Partnership (CBP) paired selected commercial building owners and operators with representatives of DOE, national laboratories and private sector exports to explore energy efficiency measures across general merchandise commercial buildings.

  4. Commercial Building Partnership Retail Food Sales Energy Savings Overview

    Energy Technology Data Exchange (ETDEWEB)

    None

    2013-03-01

    The Commercial Building Partnership (CBP) paired selected commercial building owners and operators with representatives of DOE, national laboratories and private sector exports to explore energy efficiency measures across general merchandise commercial buildings.

  5. Protocol for Maximizing Energy Savings and Indoor Environmental Quality Improvements when Retrofiting Apartments

    Energy Technology Data Exchange (ETDEWEB)

    Noris, Federico [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Delp, William W. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Vermeer, Kimberly [Urban Habitat Initiatives Inc., Boston, MA (United States); Adamkiewicz, Gary [Harvard School of Public Health, Boston, MA (United States); Singer, Brett C. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Fisk, William J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-06-18

    The current focus on building energy retrofit provides an opportunity to simultaneously improve indoor environmental quality (IEQ). Toward this end, we developed a protocol for selecting packages of retrofits that both save energy and improve IEQ in apartments. The protocol specifies the methodology for selecting retrofits from a candidate list while addressing expected energy savings, IEQ impacts, and costs in an integrated manner. Interviews, inspections and measurements are specified to collect the needed input information. The protocol was applied to 17 apartments in three buildings in two different climates within California. Diagnostic measurements and surveys conducted before and after retrofit implementation indicate enhanced apartment performance.

  6. Evaluation of Savings in Energy-Efficient Public Housing in the Pacific Northwest

    Energy Technology Data Exchange (ETDEWEB)

    Gordon, A. [Building America Partnership for Improved Residential Construction (BA-PIRC), Cocoa, FL (United States); Lubliner, M. [Building America Partnership for Improved Residential Construction (BA-PIRC), Cocoa, FL (United States); Howard, L. [Building America Partnership for Improved Residential Construction (BA-PIRC), Cocoa, FL (United States); Kunkle, R. [Building America Partnership for Improved Residential Construction (BA-PIRC), Cocoa, FL (United States)

    2013-10-01

    This report presents the results of an energy performance and cost-effectiveness analysis. The Salishan phase 7 and demonstration homes were compared to Salishan phase 6 homes built to 2006 Washington State Energy Code specifications 2. Predicted annual energy savings (over Salishan phase 6) was 19% for Salishan phase 7, and between 19-24% for the demonstration homes (depending on ventilation strategy). Approximately two-thirds of the savings are attributable to the DHP. Working with the electric utility provider, Tacoma Public Utilities, researchers conducted a billing analysis for Salishan phase 7.

  7. Energy saving approaches for video streaming on smartphone based on QoE modeling

    DEFF Research Database (Denmark)

    Ballesteros, Luis Guillermo Martinez; Ickin, Selim; Fiedler, Markus

    2016-01-01

    In this paper, we study the influence of video stalling on QoE. We provide QoE models that are obtained in realistic scenarios on the smartphone, and provide energy-saving approaches for smartphone by leveraging the proposed QoE models in relation to energy. Results show that approximately 5J...... is saved in a 3 minutes video clip with an acceptable Mean Opinion Score (MOS) level when the video frames are skipped. If the video frames are not skipped, then it is suggested to avoid freezes during a video stream as the freezes highly increase the energy waste on the smartphones....

  8. Energy Savings Forecast of Solid-State Lighting in General Illumination Applications

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2014-08-29

    With declining production costs and increasing technical capabilities, LED adoption has recently gained momentum in general illumination applications. This is a positive development for our energy infrastructure, as LEDs use significantly less electricity per lumen produced than many traditional lighting technologies. The U.S. Department of Energy’s Energy Savings Forecast of Solid-State Lighting in General Illumination Applications examines the expected market penetration and resulting energy savings of light-emitting diode, or LED, lamps and luminaires from today through 2030.

  9. Protocol for maximizing energy savings and indoor environmental quality improvements when retrofitting apartments

    Energy Technology Data Exchange (ETDEWEB)

    Noris, Federico [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Delp, William W. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Vermeer, Kimberly [Urban Habitat Initiatives Inc., Boston, MA (United States); Adamkiewicz, Gary [Harvard School of Public Health, Boston, MA (United States); Singer, Brett C. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Fisk, William J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2013-06-01

    The current focus on building energy retrofit provides an opportunity to simultaneously improve indoor environmental quality (IEQ). Toward this end, we developed a protocol for selecting packages of retrofits that both save energy and improve IEQ in apartments. The protocol specifies the methodology for selecting retrofits from a candidate list while addressing expected energy savings, IEQ impacts, and costs in an integrated manner. Interviews, inspections and measurements are specified to collect the needed input information. The protocol was applied to 17 apartments in three buildings in two different climates within California. Diagnostic measurements and surveys conducted before and after retrofit implementation indicate enhanced apartment performance.

  10. Saving energy for ventilation by careful selection of building materials

    DEFF Research Database (Denmark)

    Wargocki, Pawel; Knudsen, Henrik Nellemose

    2008-01-01

    The main objective of the research project described in this paper was to study the potential of reducing energy used for ventilating buildings by using low-polluting building materials without compromising indoor air quality.......The main objective of the research project described in this paper was to study the potential of reducing energy used for ventilating buildings by using low-polluting building materials without compromising indoor air quality....

  11. Energy Saving Potential by Utilizing Natural Ventilation under Warm Conditions

    DEFF Research Database (Denmark)

    Oropeza-Perez, Ivan; Østergaard, Poul Alberg

    2014-01-01

    The objective of this article is to show the potential of natural ventilation as a passive cooling method within the residential sector of countries which are located in warm conditions using Mexico as a case study. The method is proposed as performing, with a simplified ventilation model, thermal......, corresponding to 54.4% of the Mexican electric cooling demand for the same year. The practical implications of the study are that the results contribute to an assessment of the economic and environmental benefits for using natural ventilation rather than an active method such as air conditioning. Thereby...

  12. Energy efficient thermal management of data centers

    CERN Document Server

    Kumar, Pramod

    2012-01-01

    Energy Efficient Thermal Management of Data Centers examines energy flow in today's data centers. Particular focus is given to the state-of-the-art thermal management and thermal design approaches now being implemented across the multiple length scales involved. The impact of future trends in information technology hardware, and emerging software paradigms such as cloud computing and virtualization, on thermal management are also addressed. The book explores computational and experimental characterization approaches for determining temperature and air flow patterns within data centers. Thermodynamic analyses using the second law to improve energy efficiency are introduced and used in proposing improvements in cooling methodologies. Reduced-order modeling and robust multi-objective design of next generation data centers are discussed. This book also: Provides in-depth treatment of energy efficiency ideas based on  fundamental heat transfer, fluid mechanics, thermodynamics, controls, and computer science Focus...

  13. Energy saving mechanisms, collective behavior and the variation range hypothesis in biological systems: A review.

    Science.gov (United States)

    Trenchard, Hugh; Perc, Matjaž

    2016-09-01

    Energy saving mechanisms are ubiquitous in nature. Aerodynamic and hydrodynamic drafting, vortice uplift, Bernoulli suction, thermoregulatory coupling, path following, physical hooks, synchronization, and cooperation are only some of the better-known examples. While drafting mechanisms also appear in non-biological systems such as sedimentation and particle vortices, the broad spectrum of these mechanisms appears more diversely in biological systems that include bacteria, spermatozoa, various aquatic species, birds, land animals, semi-fluid dwellers like turtle hatchlings, as well as human systems. We present the thermodynamic framework for energy saving mechanisms, and we review evidence in favor of the variation range hypothesis. This hypothesis posits that, as an evolutionary process, the variation range between strongest and weakest group members converges on the equivalent energy saving quantity that is generated by the energy saving mechanism. We also review self-organized structures that emerge due to energy saving mechanisms, including convective processes that can be observed in many systems over both short and long time scales, as well as high collective output processes in which a form of collective position locking occurs. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  14. Energy Savings and Breakeven Cost for Residential Heat Pump Water Heaters in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Maguire, J.; Burch, J.; Merrigan, T.; Ong, S.

    2013-07-01

    Heat pump water heaters (HPWHs) have recently reemerged in the U.S. residential water heating market and have the potential to provide homeowners with significant energy savings. However, there are questions as to the actual performance and energy savings potential of these units, in particular in regards to the heat pump's performance in unconditioned space and the impact of the heat pump on space heating and cooling loads when it is located in conditioned space. To help answer these questions, simulations were performed of a HPWH in both conditioned and unconditioned space at over 900 locations across the continental United States and Hawaii. Simulations included a Building America benchmark home so that any interaction between the HPWH and the home's HVAC equipment could be captured. Comparisons were performed to typical gas and electric water heaters to determine the energy savings potential and cost effectiveness of a HPWH relative to these technologies. HPWHs were found to have a significant source energy savings potential when replacing typical electric water heaters, but only saved source energy relative to gas water heater in the most favorable installation locations in the southern US. When replacing an electric water heater, the HPWH is likely to break even in California, the southern US, and parts of the northeast in most situations. However, the HPWH will only break even when replacing a gas water heater in a few southern states.

  15. Energy Savings and Breakeven Costs for Residential Heat Pump Water Heaters in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Maguire, Jeff [National Renewable Energy Lab. (NREL), Golden, CO (United States); Burch, Jay [National Renewable Energy Lab. (NREL), Golden, CO (United States); Merrigan, Tim [National Renewable Energy Lab. (NREL), Golden, CO (United States); Ong, Sean [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2013-07-01

    Heat pump water heaters (HPWHs) have recently re-emerged in the U.S. residential water heating market and have the potential to provide homeowners with significant energy savings. However, there are questions as to the actual performance and energy savings potential of these units, in particular in regards to the heat pump's performance in unconditioned space and the impact of the heat pump on space heating and cooling loads when it is located in conditioned space. To help answer these questions, NREL performed simulations of a HPWH in both conditioned and unconditioned space at over 900 locations across the continental United States and Hawaii. Simulations included a Building America benchmark home so that any interaction between the HPWH and the home's HVAC equipment could be captured. Comparisons were performed to typical gas and electric water heaters to determine the energy savings potential and cost effectiveness of a HPWH relative to these technologies. HPWHs were found to have a significant source energy savings potential when replacing typical electric water heaters, but only saved source energy relative to gas water heater in the most favorable installation locations in the southern United States. When replacing an electric water heater, the HPWH is likely to break even in California, the southern United States, and parts of the northeast in most situations. However, the HPWH will only break even when replacing a gas water heater in a few southern states.

  16. Energy saving potentials for industrial steam boilers - findings from the ecodesign process

    OpenAIRE

    Aydemir, Ali; Braimakis, Konstantinos; Rohde, Clemens; Karellas, Sotirios; Ostrander, Berit

    2015-01-01

    Ecodesign is an important instrument of European energy policy making, which drives technological development and leads to significant energy savings by improving the environmental performance of energy-related products. Minimum energy performance standards and voluntary agreements which have been introduced under the Ecodesign Directive and so far concern more than 20 different product groups. One of the product groups currently investigated for possible regulation includes industrial steam ...

  17. Analysis of Energy Saving Impacts of ASHRAE 90.1-2004 for New York

    Energy Technology Data Exchange (ETDEWEB)

    Gowri, Krishnan; Halverson, Mark A.; Richman, Eric E.

    2007-08-03

    The New York State Energy Research and Development Authority (NYSERDA) and New York State Department of State (DOS) requested the help of DOE’s Building Energy Codes Program (BECP) in estimating the annual building energy savings and cost impacts of adopting ANSI/ASHRAE/IESNA Standard 90.1-2004 (ASHRAE 2004) requirements. This report summarizes the analysis methodology and results of energy simulation in response to that request.

  18. Savings estimates for the ENERGY STAR (registered trademark) voluntary labeling program: 2001 status report

    Energy Technology Data Exchange (ETDEWEB)

    Webber, Carrie A.; Brown, Richard E.; Mahajan, Akshay; Koomey, Jonathan G.

    2002-02-15

    ENERGY STAR(Registered Trademark) is a voluntary labeling program designed to identify and promote energy-efficient products, buildings and practices. Operated jointly by the Environmental Protection Agency (EPA) and the U.S. Department of Energy (DOE), ENERGY STAR labels exist for more than thirty products, spanning office equipment, residential heating and cooling equipment, commercial and residential lighting, home electronics, and major appliances. This report presents savings estimates for a subset of ENERGY STAR program activities, focused primarily on labeled products. We present estimates of the energy, dollar and carbon savings achieved by the program in the year 2000, what we expect in 2001, and provide savings forecasts for two market penetration scenarios for the period 2001 to 2020. The target market penetration forecast represents our best estimate of future ENERGY STAR savings. It is based on realistic market penetration goals for each of the products. We also provide a forecast under the assumption of 100 percent market penetration; that is, we assume that all purchasers buy ENERGY STAR-compliant products instead of standard efficiency products throughout the analysis period.

  19. 2004 status report: Savings estimates for the Energy Star(R)voluntarylabeling program

    Energy Technology Data Exchange (ETDEWEB)

    Webber, Carrie A.; Brown, Richard E.; McWhinney, Marla

    2004-03-09

    ENERGY STAR(R) is a voluntary labeling program designed toidentify and promote energy-efficient products, buildings and practices.Operated jointly by the Environmental Protection Agency (EPA) and theU.S. Department of Energy (DOE), ENERGY STAR labels exist for more thanthirty products, spanning office equipment, residential heating andcooling equipment, commercial and residential lighting, home electronics,and major appliances. This report presents savings estimates for a subsetof ENERGY STAR labeled products. We present estimates of the energy,dollar and carbon savings achieved by the program in the year 2003, whatwe expect in 2004, and provide savings forecasts for two marketpenetration scenarios for the periods 2004 to 2010 and 2004 to 2020. Thetarget market penetration forecast represents our best estimate of futureENERGY STAR savings. It is based on realistic market penetration goalsfor each of the products. We also provide a forecast under the assumptionof 100 percent market penetration; that is, we assume that all purchasersbuy ENERGY STAR-compliant products instead of standard efficiencyproducts throughout the analysis period.

  20. 2003 status report savings estimates for the energy star(R)voluntary labeling program

    Energy Technology Data Exchange (ETDEWEB)

    Webber, Carrie A.; Brown, Richard E.; McWhinney, Marla

    2004-11-09

    ENERGY STAR(R) is a voluntary labeling program designed to identify and promote energy-efficient products, buildings and practices. Operated jointly by the Environmental Protection Agency (EPA) and the U.S. Department of Energy (DOE), ENERGY STAR labels exist for more than thirty products, spanning office equipment, residential heating and cooling equipment, commercial and residential lighting, home electronics, and major appliances. This report presents savings estimates for a subset of ENERGY STAR program activities, focused primarily on labeled products. We present estimates of the energy, dollar and carbon savings achieved by the program in the year 2002, what we expect in 2003, and provide savings forecasts for two market penetration scenarios for the period 2003 to 2020. The target market penetration forecast represents our best estimate of future ENERGY STAR savings. It is based on realistic market penetration goals for each of the products. We also provide a forecast under the assumption of 100 percent market penetration; that is, we assume that all purchasers buy ENERGY STAR-compliant products instead of standard efficiency products throughout the analysis period.

  1. 2002 status report: Savings estimates for the ENERGY STAR(R) voluntary labeling program

    Energy Technology Data Exchange (ETDEWEB)

    Webber, Carrie A.; Brown, Richard E.; McWhinney, Marla; Koomey, Jonathan

    2003-03-03

    ENERGY STAR [registered trademark] is a voluntary labeling program designed to identify and promote energy-efficient products, buildings and practices. Operated jointly by the Environmental Protection Agency (EPA) and the U.S. Department of Energy (DOE), ENERGY STAR labels exist for more than thirty products, spanning office equipment, residential heating and cooling equipment, commercial and residential lighting, home electronics, and major appliances. This report presents savings estimates for a subset of ENERGY STAR program activities, focused primarily on labeled products. We present estimates of the energy, dollar and carbon savings achieved by the program in the year 2001, what we expect in 2002, and provide savings forecasts for two market penetration scenarios for the period 2002 to 2020. The target market penetration forecast represents our best estimate of future ENERGY STAR savings. It is based on realistic market penetration goals for each of the products. We also provide a forecast under the assumption of 100 percent market penetration; that is, we assume that all purchasers buy ENERGY STAR-compliant products instead of standard efficiency products throughout the analysis period.

  2. 2005 Status Report Savings Estimates for the ENERGY STAR(R)Voluntary Labeling Program

    Energy Technology Data Exchange (ETDEWEB)

    Webber, Carrie A.; Brown, Richard E.; Sanchez, Marla

    2006-03-07

    ENERGY STAR(R) is a voluntary labeling program designed toidentify and promote energy-efficient products, buildings and practices.Operated jointly by the Environmental Protection Agency (EPA) and theU.S. Department of Energy (DOE), Energy Star labels exist for more thanforty products, spanning office equipment, residential heating andcooling equipment, commercial and residential lighting, home electronics,and major appliances. This report presents savings estimates for a subsetof ENERGY STAR labeled products. We present estimates of the energy,dollar and carbon savings achieved by the program in the year 2004, whatwe expect in 2005, and provide savings forecasts for two marketpenetration scenarios for the periods 2005 to 2010 and 2005 to 2020. Thetarget market penetration forecast represents our best estimate of futureENERGY STAR savings. It is based on realistic market penetration goalsfor each of the products. We also provide a forecast under the assumptionof 100 percent market penetration; that is, we assume that all purchasersbuy ENERGY STAR-compliant products instead of standard efficiencyproducts throughout the analysis period.

  3. 2006 Status Report Savings Estimates for the ENERGY STAR(R)Voluntary Labeling Program

    Energy Technology Data Exchange (ETDEWEB)

    Webber, Carrie A.; Brown, Richard E.; Sanchez, Marla; Homan,Gregory K.

    2006-03-07

    ENERGY STAR(R) is a voluntary labeling program designed toidentify and promote energy-efficient products, buildings and practices.Operated jointly by the Environmental Protection Agency (EPA) and theU.S. Department of Energy (DOE), ENERGY STAR labels exist for more thanthirty products, spanning office equipment, residential heating andcooling equipment, commercial and residential lighting, home electronics,and major appliances. This report presents savings estimates for a subsetof ENERGY STAR labeled products. We present estimates of the energy,dollar and carbon savings achieved by the program in the year 2005, whatwe expect in 2006, and provide savings forecasts for two marketpenetration scenarios for the periods 2006 to 2015 and 2006 to 2025. Thetarget market penetration forecast represents our best estimate of futureENERGY STAR savings. It is based on realistic market penetration goalsfor each of the products. We also provide a forecast under the assumptionof 100 percent market penetration; that is, we assume that all purchasersbuy ENERGY STAR-compliant products instead of standard efficiencyproducts throughout the analysis period.

  4. 2007 Status Report: Savings Estimates for the ENERGY STAR(R)VoluntaryLabeling Program

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez, Marla; Webber, Carrie A.; Brown, Richard E.; Homan,Gregory K.

    2007-03-23

    ENERGY STAR(R) is a voluntary labeling program designed toidentify and promote energy-efficient products, buildings and practices.Operated jointly by the Environmental Protection Agency (EPA) and theU.S. Department of Energy (DOE), ENERGY STAR labels exist for more thanthirty products, spanning office equipment, residential heating andcooling equipment, commercial and residential lighting, home electronics,and major appliances. This report presents savings estimates for a subsetof ENERGY STAR labeled products. We present estimates of the energy,dollar and carbon savings achieved by the program in the year 2006, whatwe expect in 2007, and provide savings forecasts for two marketpenetration scenarios for the periods 2007 to 2015 and 2007 to 2025. Thetarget market penetration forecast represents our best estimate of futureENERGY STAR savings. It is based on realistic market penetration goalsfor each of the products. We also provide a forecast under the assumptionof 100 percent market penetration; that is, we assume that all purchasersbuy ENERGY STAR-compliant products instead of standard efficiencyproducts throughout the analysis period.

  5. Vapor-phase diethyl oxalate pretreatment of wood chips. Part 1, Energy savings and improved pulps

    Science.gov (United States)

    William Kenealy; Eric Horn; Carl Houtman

    2007-01-01

    Diethyl oxalate (DEO) was injected into a digester containing wood chips (pine, spruce, or aspen) preheated to 130–1408C and held for 30 min at the same temperature. When mechanical pulps were produced from these pretreated chips, savings in electrical refiner energy could be achieved. For southern yellow pine (Pinus taeda), the electrical refiner energy required to...

  6. Development of Design Guidance for K-12 Schools from 30% to 50% Energy Savings: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Pless, S.; Torcellini, P.; Long, N.

    2008-07-01

    This paper describes the development of energy efficiency recommendations for achieving 30% whole-building energy savings in K-12 schools over levels achieved by following the ANSI/ASHRAE/IESNA Standard 90.1. These design recommendations look at building envelope, fenestration, lighting systems (including electrical lights and daylighting), HVAC systems, building automation and controls, outside air treatment, and service water heating.

  7. An endogenous growth model with embodied energy-saving technical change

    NARCIS (Netherlands)

    van Zon, A; Yetkiner, IH

    In this paper, we extend the Romer [Journal of Political Economy 98 (Part 2) (1990) S271] model in two ways. First we include energy consumption of intermediates. Second, intermediates become heterogeneous due to endogenous energy-saving technical change. We show that the resulting model can still

  8. Wind Energy to Thermal and Cold Storage – A Systems Approach

    DEFF Research Database (Denmark)

    Xydis, George

    2013-01-01

    In this paper wind energy to thermal and cold storage scenarios were examined to enable high wind integration through converting renewable electricity excess into thermal or cooling energy, saving part of the energy used in an area and eliminating the need to possibly build a new coal fired plant....... Case studies in Crete Island (not interconnected to the power grid of Greek mainland) with onshore wind power installed were investigated. The aim of this work was to review the options for greater integration of renewables into the grid and the main idea was to analyze the wind to thermal and to cold...

  9. Promoting energy-saving and environmentally friendly generation dispatching model in China: Phase development and case studies

    DEFF Research Database (Denmark)

    Ding, Yi; Yang, Hongliang

    2013-01-01

    Energy saving and environmental protection are important conditions for the sustainable development of Chinese economy. However current widely used generation scheduling model based on predefined production quota and tariff results in heavy energy consumption and severe environment pollution. From...... scheduling models in China. The institutional and technical barriers impeding the implementation of energy-saving generation dispatching model are identified. The development of advanced energy-saving generation scheduling models towards competitive market models and phased planning programs are emphasized...

  10. Enhancing radiative energy transfer through thermal extraction

    Science.gov (United States)

    Tan, Yixuan; Liu, Baoan; Shen, Sheng; Yu, Zongfu

    2016-06-01

    Thermal radiation plays an increasingly important role in many emerging energy technologies, such as thermophotovoltaics, passive radiative cooling and wearable cooling clothes [1]. One of the fundamental constraints in thermal radiation is the Stefan-Boltzmann law, which limits the maximum power of far-field radiation to P0 = σT4S, where σ is the Boltzmann constant, S and T are the area and the temperature of the emitter, respectively (Fig. 1a). In order to overcome this limit, it has been shown that near-field radiations could have an energy density that is orders of magnitude greater than the Stefan-Boltzmann law [2-7]. Unfortunately, such near-field radiation transfer is spatially confined and cannot carry radiative heat to the far field. Recently, a new concept of thermal extraction was proposed [8] to enhance far-field thermal emission, which, conceptually, operates on a principle similar to oil immersion lenses and light extraction in light-emitting diodes using solid immersion lens to increase light output [62].Thermal extraction allows a blackbody to radiate more energy to the far field than the apparent limit of the Stefan-Boltzmann law without breaking the second law of thermodynamics. Thermal extraction works by using a specially designed thermal extractor to convert and guide the near-field energy to the far field, as shown in Fig. 1b. The same blackbody as shown in Fig. 1a is placed closely below the thermal extractor with a spacing smaller than the thermal wavelength. The near-field coupling transfers radiative energy with a density greater than σT4. The thermal extractor, made from transparent and high-index or structured materials, does not emit or absorb any radiation. It transforms the near-field energy and sends it toward the far field. As a result, the total amount of far-field radiative heat dissipated by the same blackbody is greatly enhanced above SσT4, where S is the area of the emitter. This paper will review the progress in thermal

  11. Saving energy by overriding automatic lighting control: A case study

    NARCIS (Netherlands)

    Lelkens, A.

    2011-01-01

    Modern office buildings are often equipped with automatic systems that turn on the lights if somebody enters a room and turn them off when everybody has left the room. This ensures that users do not leave the lights on during the night and thus avoids wasting energy. For cost reasons, most of these

  12. Smartness and Urban Resilience. A Model of Energy Saving

    Directory of Open Access Journals (Sweden)

    Carmela Gargiulo

    2015-10-01

    The results have shown that the possibility of identifying an "ideal" sustainable urban form, able to maximize energy efficiency, still remains theoretical, opening up the possibility that there are different consumption patterns due to the different physical, environmental and building characteristics of urban areas.

  13. Actual Energy Savings of Renovated Dwellings : the Case of Amsterdam

    NARCIS (Netherlands)

    Filippidou, F.; Nieboer, N.E.T.; Itard, L.C.M.; Heiselberg, Per Kvols

    2016-01-01

    The existing housing stock plays a major role in the realization of the energy efficiency targets. The non-profit housing sector in the Netherlands dominates the housing market as it represents 31% of the total housing stock. In the municipality of Amsterdam, where this share is even 46%, subsidies

  14. Heat savings in energy systems with substantial distributed generation

    DEFF Research Database (Denmark)

    Østergaard, Poul Alberg

    2004-01-01

    The integration of flutuating wind power is an important issue for the future development of sustainable energy systems. In Denmark, the integration is affected by a large amount of cogeneration of heat and power. This gives possibilities as well as sets restraints. The paper shows...

  15. Energy in Solid Waste: A Citizen Guide to Saving.

    Science.gov (United States)

    Citizens Advisory Committee on Environmental Quality.

    This booklet contains information for citizens on solid wastes. It discusses the possible energy available in combustible and noncombustible trash. It suggests how citizens can reduce waste at home through discriminating buying practices and through recycling and reuse of resources. Recommendations are given for community action along with state…

  16. Smart thermochromic glazing for energy saving window applications

    Science.gov (United States)

    Arutjunjan, Ruben; Markova, Tatiana; Halopenen, Ilya; Maksimov, Ivan; Tutunnikov, Anatolii; Yanush, Oleg

    2005-08-01

    Thermochromic laminated glazing (TLG) aids in reducing the energy needs of a building and providing indoor comfort. The polymeric interlayer of TLG is doped with transition metal (Fe, Cr, W, etc.) complexes, which change their coordination and the transmission or color of TLG under the influence of light and heat fluxes. At present we have conversions fiom light gray or brown to dark gray or brown and fiom rosy or yellow to blue or green at our disposal. TLG is able to sense changes in the light and adjust accordingly. It can block out the sunlight during the brightest parts of the day or capitalize on the available light during overcast days. As evaluated on the basis of tests, TLG has a good UV stability. It offers practical benefits of a low cost and easy fabrication. No electrical or any other driving power is needed to operate TLG. The energy modeling of the heat transfer in ventilated facades showed that TLG can provide a 15-30% decrease of the building energy consumption during the winter heating time in the climatic conditions of some regions in Russia. During the summer season the reduction of the solar energy gain reaches 30-40%; this is enough to give up air- cooling systems altogether.

  17. Another Approach to Save Energy in OFDM Systems

    NARCIS (Netherlands)

    Shao, X.; Slump, Cornelis H.

    2010-01-01

    In this paper, we propose an energy-efficient error correction scheme to lower the power consumption of the ADCs in the OFDM system. The proposed opportunistic error correction scheme is based on resolution adaptive ADCs and fountain codes. The key idea is to reduce the dynamic range of the channel

  18. An engineering and economic comparison of energy saving variations

    Energy Technology Data Exchange (ETDEWEB)

    Justian, F.

    1979-01-01

    A methodology is given for determining the engineering and economic merit of engineering processes in which the cost of energy is accounted for in the form of a separate component together with the actual cost of the raw materials. The use of the methodology is clarified in a sample evaluation of the cellulose fiberboard and pulp produced by the cellulose and paper industry.

  19. Energy Efficiency Improvement and Cost Saving Opportunities for Cement Making. An ENERGY STAR Guide for Energy and Plant Managers

    Energy Technology Data Exchange (ETDEWEB)

    Galitsky, Christina; Worrell, Ernst; Galitsky, Christina

    2008-01-01

    The cost of energy as part of the total production costs in the cement industry is significant, warranting attention for energy efficiency to improve the bottom line. Historically, energy intensity has declined, although more recently energy intensity seems to have stabilized with the gains. Coal and coke are currently the primary fuels for the sector, supplanting the dominance of natural gas in the 1970s. Most recently, there is a slight increase in the use of waste fuels, including tires. Between 1970 and 1999, primary physical energy intensity for cement production dropped 1 percent/year from 7.3 MBtu/short ton to 5.3 MBtu/short ton. Carbon dioxide intensity due to fuel consumption and raw material calcination dropped 16 percent, from 609 lb. C/ton of cement (0.31 tC/tonne) to 510 lb. C/ton cement (0.26 tC/tonne). Despite the historic progress, there is ample room for energy efficiency improvement. The relatively high share of wet-process plants (25 percent of clinker production in 1999 in the U.S.) suggests the existence of a considerable potential, when compared to other industrialized countries. We examined over 40 energy efficient technologies and measures and estimated energy savings, carbon dioxide savings, investment costs, and operation and maintenance costs for each of the measures. The report describes the measures and experiences of cement plants around the wold with these practices and technologies. Substantial potential for energy efficiency improvement exists in the cement industry and in individual plants. A portion of this potential will be achieved as part of (natural) modernization and expansion of existing facilities, as well as construction of new plants in particular regions. Still, a relatively large potential for improved energy management practices exists.

  20. Energy Saving Melting and Revert Reduction Technology (Energy SMARRT): Manufacturing Advanced Engineered Components Using Lost Foam Casting Technology

    Energy Technology Data Exchange (ETDEWEB)

    Littleton, Harry; Griffin, John

    2011-07-31

    This project was a subtask of Energy Saving Melting and Revert Reduction Technology (Energy SMARRT) Program. Through this project, technologies, such as computer modeling, pattern quality control, casting quality control and marketing tools, were developed to advance the Lost Foam Casting process application and provide greater energy savings. These technologies have improved (1) production efficiency, (2) mechanical properties, and (3) marketability of lost foam castings. All three reduce energy consumption in the metals casting industry. This report summarizes the work done on all tasks in the period of January 1, 2004 through June 30, 2011. Current (2011) annual energy saving estimates based on commercial introduction in 2011 and a market penetration of 97% by 2020 is 5.02 trillion BTU's/year and 6.46 trillion BTU's/year with 100% market penetration by 2023. Along with these energy savings, reduction of scrap and improvement in casting yield will result in a reduction of the environmental emissions associated with the melting and pouring of the metal which will be saved as a result of this technology. The average annual estimate of CO2 reduction per year through 2020 is 0.03 Million Metric Tons of Carbon Equivalent (MM TCE).

  1. COSTS OF THERMAL ENERGY STORAGE TECHNOLOGIES

    Directory of Open Access Journals (Sweden)

    Debrayan Bravo Hidalgo

    2017-10-01

    Full Text Available Thermal accumulation facilities allow energy to be available in the absence of sunlight. This fact reduces the difficulty of the intermittence in the incidence of the king star in our planet. Thermal accumulation technology also contributes to smooth the fluctuations in energy demand during different times of the day. This contribution identifies the nations with the most favorable research results in this area; as well as the main research lines that are being developed today. A compendium of various thermal energy storage materials, their current costs per unit mass, and their physical properties are presented. Techniques for implementing thermal accumulation technologies can be classified as areas of high, medium and low temperature. In the high temperature area, inorganic materials such as nitrate salts are the most widely used thermal energy storage materials, while in the medium and lower temperature areas; organic materials such as commercial paraffin are more common. Currently, one of the research trends in this area are the projects aimed at optimizing the chemical and physical characteristics of thermal storage materials, because the success of any thermos-energetic storage technology has a strong dependence on the cost of the materials selected for thermal storage.

  2. Durability of high-albedo roof coatings and implications for cooling energy savings. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Bretz, S.E.; Akbari, H.

    1994-06-01

    Twenty-six spot albedo measurements of roofs were made using a calibrated pyranometer. The roofs were surfaced with either an acrylic elastomeric coating, a polymer coating with an acrylic base, or a cementitious coating. Some of the roofs` albedos were measured before and after washing to determine whether the albedo decrease was permanent. Data indicated that most of the albedo degradation occurred within the first year, and even within the first two months. On one roof, 70% of one year`s albedo degradation occurred in the first two months. After the first year, the degradation slowed, with data indicating small losses in albedo after the second year. Measurements of seasonal cooling energy savings by Akbari et al. (1993) included the effects of over two months of albedo degradation. We estimated {approximately}20% loss in cooling-energy savings after the first year because of dirt accumulation. For most of the roofs we cleaned, the albedo was restored to within 90% of its initial value. Although washing is effective at restoring albedo, the increase in energy savings is temporary and labor costs are significant in comparison to savings. By our calculations, it is not cost-effective to hire someone to clean a high-albedo roof only to achieve energy savings. Thus, it would be useful to develop and identify dirt-resistant high-albedo coatings.

  3. Graphene Thermal Properties: Applications in Thermal Management and Energy Storage

    Directory of Open Access Journals (Sweden)

    Jackie D. Renteria

    2014-11-01

    Full Text Available We review the thermal properties of graphene, few-layer graphene and graphene nanoribbons, and discuss practical applications of graphene in thermal management and energy storage. The first part of the review describes the state-of-the-art in the graphene thermal field focusing on recently reported experimental and theoretical data for heat conduction in graphene and graphene nanoribbons. The effects of the sample size, shape, quality, strain distribution, isotope composition, and point-defect concentration are included in the summary. The second part of the review outlines thermal properties of graphene-enhanced phase change materials used in energy storage. It is shown that the use of liquid-phase-exfoliated graphene as filler material in phase change materials is promising for thermal management of high-power-density battery parks. The reported experimental and modeling results indicate that graphene has the potential to outperform metal nanoparticles, carbon nanotubes, and other carbon allotropes as filler in thermal management materials.

  4. Trend of Energy Saving in Electronic Devices for Research and Development

    Directory of Open Access Journals (Sweden)

    Rahmayanti R.

    2016-01-01

    Full Text Available In electronic industry, energy saving is one of the performance indicators of competitiveness beside price, speed, bandwidth and reliability. This affects research and development (R&D activity in mechatronic systems which uses electronic components and electronic systems. A review of trend of electronic devices technology development has been conducted with focus on energy saving. This review includes electronic devices, semiconductor, and nanotechnology. It can be concluded that the trend in electronic devices is mainly dictated by semiconductor technology development. The trend can be concluded as smaller size, lower voltage leading to energy saving, less heat, higher speed, more reliable, and cheaper. In accordance to such technology development, R&D activities in mechatronics especially in Indonesia is being pushed to make proper alignment.Some of such alignment actions are surface mount technology (SMT for installing surface mount devices components (SMD, design layout and SMD troubleshooting tools as well as human resources training and development.

  5. Application of Waste Heat Recovery Energy Saving Technology in Reform of UHP-EAF

    Science.gov (United States)

    Zhao, J. H.; Zhang, S. X.; Yang, W.; Yu, T.

    2017-08-01

    The furnace waste heat of a company’s existing 4 × 100t ultra-high-power electric arc furnaces is not used and discharged directly of the situation has been unable to meet the national energy-saving emission reduction requirements, and also affected their own competitiveness and sustainable development. In order to make full use of the waste heat of the electric arc furnace, this paper presents an the energy-saving transformation program of using the new heat pipe boiler on the existing ultra-high-power electric arc furnaces for recovering the waste heat of flue gas. The results show that after the implementation of the project can save energy equivalent to 42,349 tons of standard coal. The flue gas waste heat is fully utilized and dust emission concentration is accorded with the standard of Chinese invironmental protection, which have achieved good results.

  6. Modeling Interprovincial Cooperative Energy Saving in China: An Electricity Utilization Perspective

    Directory of Open Access Journals (Sweden)

    Lijun Zeng

    2018-01-01

    Full Text Available As the world faces great challenges from climate change and environmental pollution, China urgently requires energy saving, emission reduction, and carbon reduction programmes. However, the non-cooperative energy saving model (NCESM, the simple regulation mode that is China’s main model for energy saving, is not beneficial for optimization of energy and resource distribution, and cannot effectively motivate energy saving at the provincial level. Therefore, we propose an interprovincial cooperative energy saving model (CESM from the perspective of electricity utilization, with the object of maximizing the benefits from electricity utilization of the cooperation union based on achieving the energy saving goals of the union as a whole. The CESM consists of two parts: (1 an optimization model that calculates the optimal quantities of electricity consumption for each participating province to meet the joint energy saving goal; and (2 a model that distributes the economic benefits of the cooperation among the provinces in the cooperation based on the Shapley value method. We applied the CESM to the case of an interprovincial union of Shanghai, Sichuan, Shanxi, and Gansu in China. The results, based on the data from 2001–2014, show that cooperation can significantly increase the benefits of electricity utilization for each province in the union. The total benefits of the union from utilization of electricity increased 38.38%, or 353.98 billion CNY, while the benefits to Shanghai, Sichuan, Shanxi, and Gansu were 200.28, 58.37, 57.11, and 38.22 billion CNY respectively greater under the CESM than the NCESM. The implementation of the CESM provides the provincial governments not only a flexible and incentive way to achieve short-term goals, but also a feasible and effective path to realize long-term energy saving strategies. To test the impact of different parameter values on the results of the CESM, a sensitivity analysis was conducted. Some policy

  7. Energy-saving with low dimensional network in Physarum plasmodium

    Science.gov (United States)

    Takamatsu, Atsuko; Gomi, Takuma; Endo, Tatsuya; Hirai, Tomo; Sasaki, Takato

    2017-04-01

    An adaptation process in the transportation network of Physarum plasmodium was investigated by measuring oxygen consumption during network formation. Simultaneously, the fractal dimension as a measure of network structure was estimated. Oxygen consumption decreased during the development of the network, whereas the network structure changed from a thin mesh-type to a thick dendritic type. Our data suggested that the morphology of the plasmodial network governed energy consumption; a low dimensional network in the sense of the fractal dimension reduced energy consumption. These data were supported by experimental results excluding biological reasons, such as differences in starvation/nutrient-fullness states, and aspects of mitochondrial distribution. Model analysis using the Physarum algorithm with volume conservation constraints confirmed the above findings.

  8. Energy-Saving and Process Technologies Development at ORNL

    Science.gov (United States)

    2004-02-26

    Modulator Digital Decimation Filter High-Resolution Σ∆ ADC Chipset (0.5µm SOS-CMOS) Rail-to-Rail High Temperature OPAMP Constant Slew Rate Design...demonstrated 50% reduction in energy consumption as compared to resistance water heater • HPWH durability testing − Accelerated life tests completed...of IR Reflective Colors Reflect more sunlight and stay cooler Lower utility bill for cooling the house Architectural appeal Better fade resistance IR

  9. Steamless brewery saves 50% energy. Stoomloze brouwerij helft zuiniger

    Energy Technology Data Exchange (ETDEWEB)

    Voorter, P.H.C.

    1991-03-01

    The greatest part of the heat demand of the Heineken brewery is supplied by hot water systems for four temperature levels. Part of the heat from these systems is recovered from the wort vapors which are released during the boiling of the brewage. The rest of the heat is supplied by a heat-power system. The energy costs of such an economic brewery are 50% lower. 1 fig., 1 ill., 2 tabs.

  10. The challenge to UK energy policy. An ageing population perspective on energy saving measures and consumption

    Energy Technology Data Exchange (ETDEWEB)

    Hamza, Neveen; Gilroy, Rose [School of Architecture, Planning and Landscape Newcastle University, NE1 7RU (United Kingdom)

    2011-02-15

    With a focus on the residential sector, this paper explores the likelihood of the UK government meeting its energy targets. The paper contends that energy policy needs to take into account the interplay of four major factors: an ageing population of increasing diversity; a cultural inclination for older housing much of which is thermally inefficient; levels of fuel poverty; and the inexorable rise of consumer spending on leisure related services and goods. Decisions made by older households (both the poorer and the better off) may be critical to the success of energy policy. Among the better off the changing expectations of the baby boomers, with their predilection for consumption and travel, may have particular impact. The paper concludes that much of the reduction in carbon footprint made by older people's choices in heating and insulation may be offset, not only by increasing domestic thermal comfort, but also potentially by increasing consumables in the home and other consumer lifestyle choices. What could be achieved at best, may be a shift in energy mix. (author)

  11. Laptop energy-saving opportunities based on user behaviors

    Energy Technology Data Exchange (ETDEWEB)

    Jones, M.E. Jr; Hung, D.L. [College of Engineering, San Jose State University, One Washington Square, San Jose, CA 95192 (United States); Wei, B.W.Y. [Academic Affairs Division, Chico State University, Kendall Hall 106, Chico, CA 95929 (United States)

    2013-05-15

    In order to improve the energy efficiency of laptop use and design, it is important to gain knowledge of how laptops are being used in real-world settings. However, the current workload studies have focused on computer-usage patterns of business users, but not those of consumer users. As part of the Green project at ABC University, a pilot study was undertaken to develop and test software tools and methods for monitoring the laptop computer usage of 13 college students for a period of 1 month. This paper describes such tools and methods for monitoring and collecting laptop usage data. It also illustrates how the collected data can be analyzed to obtain high-impact energy usage patterns, which include long idle periods, excessive use of the AC power source, and high backlight levels. These identified high-impact usage patterns, if confirmed by our subsequent study, offer valuable user behavioral insights to advance more energy-efficient laptop use and design.

  12. Evaluation of energy saving tasks performed by the energy transmission and distribution companies; Denmark; Evaluering af energiselskabernes energibespareaktiviteter

    Energy Technology Data Exchange (ETDEWEB)

    Togeby, M. (Ea Energianalyse A/S, Copenhagen (Denmark))

    2012-05-15

    The evaluation is described in the Agreement of 20 November 2009 between the Danish Climate and Energy Minister and the distribution companies for electricity, natural gas, district heating and oil about the companies' future energy conservation efforts. The evaluation was conducted to provide recommendations for adjusting the system. The results of the evaluation show that energy companies and utilities meet the overall savings obligation. In 2011, 2,098 GWh savings are recorded, which is more than the obligation. The evaluation shows that the net effect is about 760 GWh (36%). When looking at types of energy companies, then the oil companies' activities generally have a low net effect and additionally is assessed to be low in relation to the district heating companies' renovation of the district heating network. The greatest additionally exists among large savings in the industry. The means that energy companies use to achieve savings obligations are significantly different today than a few years ago. Today there are grants for more than 85% of registered savings. Before 2006 primarily information and advice was used. Thus an estimated 400 million DKK annually is used for grants. Socio-economics is positive for the part of the effort that is aimed at businesses. The socio-economic value of the savings is calculated to be twice as large as the total cost when you only look at the industry. The system can thus be readily seen as a useful instrument to promote energy conservation in industry. For households, it is estimated that the net effect is 20% of the reported savings, while for industry the net effect is estimated to be 45%. Also, for renovations of the heat distribution networks the net effect is estimated to be low. (LN)

  13. Energy Efficiency Improvement and Cost Saving Oportunities for the Concrete Industry

    Energy Technology Data Exchange (ETDEWEB)

    Kermeli, Katerina; Worrell, Ernst; Masanet, Eric

    2011-12-01

    The U.S. concrete industry is the main consumer of U.S.-produced cement. The manufacturing of ready mixed concrete accounts for more than 75% of the U.S. concrete production following the manufacturing of precast concrete and masonry units. The most significant expenditure is the cost of materials accounting for more than 50% of total concrete production costs - cement only accounts for nearly 24%. In 2009, energy costs of the U.S. concrete industry were over $610 million. Hence, energy efficiency improvements along with efficient use of materials without negatively affecting product quality and yield, especially in times of increased fuel and material costs, can significantly reduce production costs and increase competitiveness. The Energy Guide starts with an overview of the U.S. concrete industry’s structure and energy use, a description of the various manufacturing processes, and identification of the major energy consuming areas in the different industry segments. This is followed by a description of general and process related energy- and cost-efficiency measures applicable to the concrete industry. Specific energy and cost savings and a typical payback period are included based on literature and case studies, when available. The Energy Guide intends to provide information on cost reduction opportunities to energy and plant managers in the U.S. concrete industry. Every cost saving opportunity should be assessed carefully prior to implementation in individual plants, as the economics and the potential energy and material savings may differ.

  14. The conservation nexus: valuing interdependent water and energy savings in Arizona.

    Science.gov (United States)

    Bartos, Matthew D; Chester, Mikhail V

    2014-02-18

    Water and energy resources are intrinsically linked, yet they are managed separately--even in the water-scarce American southwest. This study develops a spatially explicit model of water-energy interdependencies in Arizona and assesses the potential for cobeneficial conservation programs. The interdependent benefits of investments in eight conservation strategies are assessed within the context of legislated renewable energy portfolio and energy efficiency standards. The cobenefits of conservation are found to be significant. Water conservation policies have the potential to reduce statewide electricity demand by 0.82-3.1%, satisfying 4.1-16% of the state's mandated energy-efficiency standard. Adoption of energy-efficiency measures and renewable generation portfolios can reduce nonagricultural water demand by 1.9-15%. These conservation cobenefits are typically not included in conservation plans or benefit-cost analyses. Many cobenefits offer negative costs of saved water and energy, indicating that these measures provide water and energy savings at no net cost. Because ranges of costs and savings for water-energy conservation measures are somewhat uncertain, future studies should investigate the cobenefits of individual conservation strategies in detail. Although this study focuses on Arizona, the analysis can be extended elsewhere as renewable portfolio and energy efficiency standards become more common nationally and internationally.

  15. Analysis of electrical energy consumers operation in the heating plant with proposal of energy savings measures

    Directory of Open Access Journals (Sweden)

    Nikolić Aleksandar

    2016-01-01

    Full Text Available The results of power quality measurements, obtained during an energy audit in the heating plant Vreoci in the Electric Power System of Serbia, are presented in the paper. Two steam boilers, rated at 120MW each, are installed in this heating plant, using coal as a fuel. The energy audit encompassed the measurements of the complete set of parameters needed to determine the thermal efficacy of boilers and the entire heating plant. Based on the measurement results, several technical measures for improving energy efficiency of the plant are proposed. The measures evaluated in the paper should contribute to the reduction of fossil fuel usage and CO2 emissions, thereby resulting in a significant impact in both financial and ecological areas.

  16. Challenges and Opportunities To Achieve 50% Energy Savings in Homes. National Laboratory White Papers

    Energy Technology Data Exchange (ETDEWEB)

    Bianchi, Marcus V.A. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2011-07-01

    This report summarizes the key opportunities, gaps, and barriers identified by researchers from four national laboratories (Lawrence Berkeley National Laboratory, National Renewable Energy Laboratory, Oak Ridge National Laboratory, and Pacific Northwest National Laboratory) that must be addressed to achieve the longer term 50% saving goal for Building America to ensure coordination with the Building America industry teams who are focusing their research on systems to achieve the near-term 30% savings goal. Although new construction was included, the focus of the effort was on deep energy retrofits of existing homes.

  17. Study on key technologies of energy-saving and environment-protective pumps

    Directory of Open Access Journals (Sweden)

    Zhang Qi-Hua

    2013-01-01

    Full Text Available To meet energy-saving and environment-protective purpose, a series of plastic pumps are developed by composite molding. There are four key techniques involved, firstly, plastic hydraulic components with light-weight; secondly, steel barrel as a pump casing and a connection component as well; thirdly, floating impeller strategy where impeller is drifting freely along shaft; and lastly, a self balancing impeller technique which can totally keep axial force balancing. The manufacturing process is energy-saving, and the components can be recycled, which have great potentials for conservation of environment.

  18. Optimizing Energy Savings from Direct-DC in U.S. Residential Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Garbesi, Karina; Vossos, Vagelis; Sanstad, Alan; Burch, Gabriel

    2011-10-13

    An increasing number of energy efficient appliances operate on direct current (DC) internally, offering the potential to use DC from renewable energy systems directly and avoiding the losses inherent in converting power to alternating current (AC) and back. This paper investigates that potential for net-metered residences with on-site photovoltaics (PV) by modeling the net power draw of the ‘direct-DC house’ with respect to today’s typical configuration, assuming identical DC-internal loads. Power draws were modeled for houses in 14 U.S. cities, using hourly, simulated PV-system output and residential loads. The latter were adjusted to reflect a 33% load reduction, representative of the most efficient DC-internal technology, based on an analysis of 32 electricity end-uses. The model tested the effect of climate, electric vehicle (EV) loads, electricity storage, and load shifting on electricity savings; a sensitivity analysis was conducted to determine how future changes in the efficiencies of power system components might affect savings potential. Based on this work, we estimate that net-metered PV residences could save 5% of their total electricity load for houses without storage and 14% for houses with storage. Based on residential PV penetration projections for year 2035 obtained from the National Energy Modeling System (2.7% for the reference case and 11.2% for the extended policy case), direct-DC could save the nation 10 trillion Btu (without storage) or 40 trillion Btu (with storage). Shifting the cooling load by two hours earlier in the day (pre-cooling) has negligible benefits for energy savings. Direct-DC provides no energy savings benefits for EV charging, to the extent that charging occurs at night. However, if charging occurred during the day, for example with employees charging while at work, the benefits would be large. Direct-DC energy savings are sensitive to power system and appliance conversion efficiencies but are not significantly

  19. Options for Water, Energy and Chemical Savings for Finitex, Cape Town

    DEFF Research Database (Denmark)

    Schneider, Zsig; Wenzel, Henrik

    An analysis of the options identified for saving of water, energy and chemicals was conducted at Finitex, Cape Town on the 18th October 2002. Cost savings were calculated from an estimation of the reduction in cost of water, energy and chemical usage associated with various interventions. Capital...... costs of implementation included cost of necessary tanks, piping, valves, and equipment, but in most cases excluded electrical, installation and possible building and alteration costs. The priority for implementation was determined by taking the ratio of the estimated implementation cost to the payback...

  20. Energy Savings Forecast of Solid-State Lighting in General Illumination Applications

    Energy Technology Data Exchange (ETDEWEB)

    Penning, Julie [Navigant Consulting Inc., Washington, DC (United States); Stober, Kelsey [Navigant Consulting Inc., Washington, DC (United States); Taylor, Victor [Navigant Consulting Inc., Washington, DC (United States); Yamada, Mary [Navigant Consulting Inc., Washington, DC (United States)

    2016-09-01

    The DOE report, Energy Savings Forecast of Solid-State Lighting in General Illumination Applications, is a biannual report which models the adoption of LEDs in the U.S. general-lighting market, along with associated energy savings, based on the full potential DOE has determined to be technically feasible over time. This version of the report uses an updated 2016 U.S. lighting-market model that is more finely calibrated and granular than previous models, and extends the forecast period to 2035 from the 2030 limit that was used in previous editions.

  1. Energy Savings Potential and Opportunities for High-Efficiency Electric Motors in Residential and Commercial Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Goetzler, William [Navigant Consulting, Inc., Burlington, MA (United States); Sutherland, Timothy [Navigant Consulting, Inc., Burlington, MA (United States); Reis, Callie [Navigant Consulting, Inc., Burlington, MA (United States)

    2013-12-04

    This report describes the current state of motor technology and estimates opportunities for energy savings through application of more advanced technologies in a variety of residential and commercial end uses. The objectives of this report were to characterize the state and type of motor technologies used in residential and commercial appliances and equipment and to identify opportunities to reduce the energy consumption of electric motor-driven systems in the residential and commercial sectors through the use of advanced motor technologies. After analyzing the technical savings potential offered by motor upgrades and variable speed technologies, recommended actions are presented.

  2. Energy savings in the production chains of Tronox

    Energy Technology Data Exchange (ETDEWEB)

    De Buck, A.; Croezen, H.; Afman, M.; Van Lieshout, M.

    2012-09-15

    For Tronox, a titanium dioxide producer at the Port of Rotterdam, CE Delft has conducted a study on the scope for improved energy efficiency and CO2 emission cuts. Because the company has already implemented numerous on-site efficiency improvements, the emphasis was now on higher-quality uses of waste streams. The scope for using biomass as a raw material was also investigated. The study was carried out in the framework of the 'MEE agreement', a voluntary agreement on energy efficiency in the energy-intensive industry, with financial support from NL Agency. Five options were elaborated in the project: (1) supply of waste heat to the Rotterdam heat grid; (2) supply of CO2 as a resource for greenhouse horticulture; (3) marketing of HCl from a wastewater stream; (4) use of a slurry waste stream as a raw material for road construction; (5) use of bio-coke as a substitute for petroleum coke. The options were analysed in terms of technological feasibility, costs/benefits and impact on CO2 emissions. Overall, the options lead to a surprisingly large reduction in the company's CO2 footprint: around 25%. Tronox will be using the results to elaborate and plan follow-up action. Prompted by this study, VNCI and NL Agency have also included the issue of bio-coke in the so-called Roadmap for the Chemical Industry and commissioned a study to examine the potential for using bio-coke throughout the Dutch chemical sector.

  3. Energy Efficiency Improvement and Cost Saving Opportunities for Breweries: An ENERGY STAR(R) Guide for Energy and Plant Managers

    Energy Technology Data Exchange (ETDEWEB)

    Galitsky, Christina; Martin, Nathan; Worrell, Ernst; Lehman, Bryan

    2003-09-01

    Annually, breweries in the United States spend over $200 million on energy. Energy consumption is equal to 38 percent of the production costs of beer, making energy efficiency improvement an important way to reduce costs, especially in times of high energy price volatility. After a summary of the beer making process and energy use, we examine energy efficiency opportunities available for breweries. We provide specific primary energy savings for each energy efficiency measure based on case studies that have implemented the measures, as well as references to technical literature. If available, we have also listed typical payback periods. Our findings suggest that given available technology, there are still opportunities to reduce energy consumption cost-effectively in the brewing industry. Brewers value highly the quality, taste and drinkability of their beer. Brewing companies have and are expected to continue to spend capital on cost-effective energy conservation measures that meet these quality, taste and drinkability requirements. For individual plants, further research on the economics of the measures, as well as their applicability to different brewing practices, is needed to assess implementation of selected technologies.

  4. Energy Consumption of Insulated Material Using Thermal Effect Analysis

    Directory of Open Access Journals (Sweden)

    Fadzil M. A.

    2017-01-01

    Full Text Available Wall is one of the structures elements that resist direct heat from the atmosphere. Modification on several structures is relevance to reduce filtrate thermal movement on wall. Insulation material seems to be suitable to be implemented since its purpose meets the heat resistance requirement. Insulation material applied as to generate positive impact in energy saving through reduction in total building energy consumption. Fiberglass is one of the insulation materials that can be used to insulate a space from heat and sound. Fiberglass is flammable insulation material with R Value rated of R-2.9 to R-3.8 which meets the requirement in minimizing heat transfer. Finite element software, ABAQUS v6.13 employed for analyze non insulated wall and other insulated wall with different wall thicknesses. The several calculations related to overall heat movement, total energy consumption per unit area of wall, life cycle cost analysis and determination of optimal insulation thickness is calculated due to show the potential of the implementation in minimize heat transfer and generate potential energy saving in building operation. It is hoped that the study can contribute to better understanding on the potential building wall retrofitting works in increasing building serviceability and creating potential benefits for building owner.

  5. Occupant-in-Place Energy Efficiency Retrofit in a Group Home for 30% Energy Savings in Climate Zone 4

    Energy Technology Data Exchange (ETDEWEB)

    Moore, Mike [Building America Partnership for Improved Residential Construction (BA-PIRC), Cocoa, FL (United States)

    2013-08-01

    Energy efficiency retrofits (EERs) face many challenges on the path to scalability. Limited budgets, cost effectiveness, risk factors, and accessibility impact the type and the extent of measures that can be implemented feasibly to achieve energy savings goals. Group home retrofits can face additional challenges than those in single family homes – such as reduced access (occupant-in-place restrictions) and lack of incentives for occupant behavioral change. This project studies the specification, implementation, and energy savings from an EER in a group home, with an energy savings goal of 30%. This short term test report chronicles the retrofit measures specified, their projected cost effectiveness using building energy simulations, and the short term test results that were used to characterize pre-retrofit and post-retrofit conditions. Additionally, the final report for the project will include analysis of pre- and post-retrofit performance data on whole building energy use, and an assessment of the energy impact of occupant interface with the building (i.e., window operation). Ultimately, the study’s results will be used to identify cost-effective EER measures that can be implemented in group homes, given constraints that are characteristic of these buildings. Results will also point towards opportunities for future energy savings.

  6. Occupant-in-Place Energy Efficiency Retrofit in a Group Home for 30% Energy Savings in Climate Zone 4

    Energy Technology Data Exchange (ETDEWEB)

    Moore, M.

    2013-08-01

    Energy efficiency retrofits (EERs) face many challenges on the path to scalability. Limited budgets, cost effectiveness, risk factors, and accessibility impact the type and the extent of measures that can be implemented feasibly to achieve energy savings goals. Group home retrofits can face additional challenges than those in single family homes - such as reduced access (occupant-in-place restrictions) and lack of incentives for occupant behavioral change. This project studies the specification, implementation, and energy savings from an EER in a group home, with an energy savings goal of 30%. This short term test report chronicles the retrofit measures specified, their projected cost-effectiveness using building energy simulations, and the short term test results that were used to characterize pre-retrofit and post-retrofit conditions. Additionally, the final report for the project will include analysis of pre- and post-retrofit performance data on whole building energy use, and an assessment of the energy impact of occupant interface with the building (i.e., window operation). Ultimately, the study's results will be used to identify cost effective EER measures that can be implemented in group homes, given constraints that are characteristic of these buildings. Results will also point towards opportunities for future energy savings.

  7. The energy saving research of the flat tire vulcanization process

    Science.gov (United States)

    Tang, X.; He, J.-Y.; Zhang, J. Y.; An, Y.; Yang, W.-M.; Tan, J.

    2015-07-01

    Vulcanization was an important step in tire production process, directly determining the mechanical properties of the tire which was the most energy-intensive link. The traditional vulcanization process of a flat tire did not consider the post curing effect, which may result in a waste of energy. Early finite element simulation showed that the traditional process caused excessive vulcanization. In order to find ways to improve the curing process, in the paper effect of process parameters on the flat tire vulcanization had been studied. Curing parameters included heating temperature, curing time and preheating temperature. Corresponding to these three factors, the three-dimensional model was established by ABAQUS finite element software to carry out three groups of simulation. Result showed that heat source temperature on the maximum temperature was the largest, effect of preheating temperature was the lowest; heat source temperature on the curing degree was the largest, effect of the curing time was lowest. According to the data analysis the optimal process parameters had been raised.

  8. Technical Support Document: 50% Energy Savings Design Technology Packages for Medium Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Thornton, Brian A.; Wang, Weimin; Lane, Michael D.; Rosenberg, Michael I.; Liu, Bing

    2009-09-01

    This Technical Support Document (TSD) describes the process and methodology for development of the Advanced Energy Design Guide for Medium Offices (AEDG-MO or the Guide), a design guidance document which intends to provide recommendations for achieving 50% energy savings in medium office buildings that just meet the requirements of ANSI/ASHRAE/IESNA Standard 90.1-2004, Energy Standard for Buildings Except Low-Rise Residential Buildings.

  9. Energy saving measures in Agriculture – Overview on the basis of national reports.

    OpenAIRE

    Golaszewski, J; Visser, C.; Stolarski, M.; Brodzinski, Z; Olba-Ziety, E; Myhan, R; Mikkola, H; Ahokas, J.; Jokiniemi, T; Rajaniemi, M; Meyer-Aurich, A.; Ziegler, T.; Briassoulis, D.; Balafoutis, A.; Mistriotis, A.

    2012-01-01

    The reduction of energy inputs in agricultural production is a process of practical implementation of a set of energy saving (ES) measures associated with a given type of production, farm infrastructure and managerial or organizational activities. In six national reports from Finland, Germany, Greece, the Netherlands, Poland and Portugal for 13 subsectors of agriculture, 481 ES measures in total were identified and classified into seven categories: 1) type of energy input: indirect, direct; 2...

  10. Energy saving techniques applied over a nation-wide mobile network

    DEFF Research Database (Denmark)

    Perez, Eva; Frank, Philipp; Micallef, Gilbert

    2014-01-01

    Traffic carried over wireless networks has grown significantly in recent years and actual forecasts show that this trend is expected to continue. However, the rapid mobile data explosion and the need for higher data rates comes at a cost of increased complexity and energy consumption of the mobile...... on the energy consumption based on a nation-wide network of a leading European operator. By means of an extensive analysis, we show that with the proposed techniques significant energy savings can be realized....

  11. 40% Whole-House Energy Savings in the Mixed-Humid Climate

    Energy Technology Data Exchange (ETDEWEB)

    Baechler, Michael C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Gilbride, T. L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hefty, M. G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Cole, P. C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Adams, K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Butner, R. S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Ortiz, S. J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Love, Pat M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2011-09-01

    This guide book is a resource to help builders design and construct highly energy-efficient homes, while addressing building durability, indoor air quality, and occupant health, safety, and comfort. With the measures described in this guide, builders in the mixed-humid climate can build homes that achieve whole house energy savings of 40% over the Building America benchmark (the 1993 Model Energy Code) with no added overall costs for consumers.

  12. 40% Whole-House Energy Savings in the Hot-Humid Climate

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2011-09-01

    This guide book is a resource to help builders design and construct highly energy-efficient homes, while addressing building durability, indoor air quality, and occupant health, safety, and comfort. With the measures described in this guide, builders in the hot-humid climate can build homes that achieve whole house energy savings of 40% over the Building America benchmark (the 1993 Model Energy Code) with no added overall costs for consumers.

  13. Evaluation of Building Energy Saving Through the Development of Venetian Blinds' Optimal Control Algorithm According to the Orientation and Window-to-Wall Ratio

    Science.gov (United States)

    Kwon, Hyuk Ju; Yeon, Sang Hun; Lee, Keum Ho; Lee, Kwang Ho

    2018-02-01

    As various studies focusing on building energy saving have been continuously conducted, studies utilizing renewable energy sources, instead of fossil fuel, are needed. In particular, studies regarding solar energy are being carried out in the field of building science; in order to utilize such solar energy effectively, solar radiation being brought into the indoors should be acquired and blocked properly. Blinds are a typical solar radiation control device that is capable of controlling indoor thermal and light environments. However, slat-type blinds are manually controlled, giving a negative effect on building energy saving. In this regard, studies regarding the automatic control of slat-type blinds have been carried out for the last couple of decades. Therefore, this study aims to provide preliminary data for optimal control research through the controlling of slat angle in slat-type blinds by comprehensively considering various input variables. The window area ratio and orientation were selected as input variables. It was found that an optimal control algorithm was different among each window-to-wall ratio and window orientation. In addition, through comparing and analyzing the building energy saving performance for each condition by applying the developed algorithms to simulations, up to 20.7 % energy saving was shown in the cooling period and up to 12.3 % energy saving was shown in the heating period. In addition, building energy saving effect was greater as the window area ratio increased given the same orientation, and the effects of window-to-wall ratio in the cooling period were higher than those of window-to-wall ratio in the heating period.

  14. energy and exergy evaluation of a 220mw thermal power plant

    African Journals Online (AJOL)

    HOD

    environmental or dead state temperature, there were no appreciable changes in the values of exergy efficiency of the boiler/steam generator. The outcomes of this work provide the exergy consumption and distribution profiles of the thermal power plant, making it possible to adopt effective energy-saving measures.

  15. Energy and exergy evaluation of a 220MW thermal power plant ...

    African Journals Online (AJOL)

    At the variation of environmental or dead state temperature, ther e were no appreciable changes in the values of exergy efficiency of the boiler/steam generator. The outcomes of this work provide the exergy consumption and distribution profile s of the thermal power plant, making it possible to adopt effective energy - saving ...

  16. Quantum energy inequalities from local thermal equilibrium

    Energy Technology Data Exchange (ETDEWEB)

    Schlemmer, Jan; Verch, Rainer [Inst. f. Theoretische Physik, Universitaet Leipzig, 04009 Leipzig (Germany)

    2008-07-01

    This talk will be about the relation between a certain notion of local thermality for states of the free scalar field on curved spacetime backgrounds and quantum energy inequalities. For states fulfilling the condition of local thermality we will present two results obtained together with for arbitrary curvature coupling: First a quantum weak energy inequality and second an expression for potential violations of the averaged null energy inequality, which involves only terms with a direct physical interpretation for the states under consideration. Furthermore this expression shows that examples proposed to point out limits to quantum energy inequalities for nonminimally coupled scalar fields are already the worst case for the set of locally thermal states.

  17. Energy Efficiency Improvement and Cost Saving Opportunities for the Glass Industry. An ENERGY STAR Guide for Energy and Plant Managers

    Energy Technology Data Exchange (ETDEWEB)

    Galitsky, Christina; Worrell, Ernst; Galitsky, Christina; Masanet, Eric; Graus, Wina

    2008-03-01

    The U.S. glass industry is comprised of four primary industry segments--flat glass, container glass, specialty glass, and fiberglass--which together consume $1.6 billion in energy annually. On average, energy costs in the U.S. glass industry account for around 14 percent of total glass production costs. Energy efficiency improvement is an important way to reduce these costs and to increase predictable earnings, especially in times of high energy price volatility. There is a variety of opportunities available at individual plants in the U.S. glass industry to reduce energy consumption in a cost-effective manner. This Energy Guide discusses energy efficiency practices and energy-efficient technologies that can be implemented at the component, process, system, and organizational levels. A discussion of the trends, structure, and energy consumption characteristics of the U.S. glass industry is provided along with a description of the major process steps in glass manufacturing. Expected savings in energy and energy-related costs are given for many energy efficiency measures, based on case study data from real-world applications in glass production facilities and related industries worldwide. Typical measure payback periods and references to further information in the technical literature are also provided, when available. The information in this Energy Guide is intended to help energy and plant managers in the U.S. glass industry reduce energy consumption in a cost-effective manner while maintaining the quality of products manufactured. Further research on the economics of the measures--as well on as their applicability to different production practices--is needed to assess potential implementation of selected technologies at individual plants.

  18. POSSIBILITY OF THE ENERGY SAVING SNAP OF SOME ORGANIC MATERIALS

    Directory of Open Access Journals (Sweden)

    Anisimov V.K.

    2006-04-01

    Full Text Available The volt - amperes characteristic of various water solutions of ethyl alcohol and multicomponent organic substances of juices and wines were investigated. Three characteristic zones are revealed. A zone of low voltage (0-3.5V and small currents fading in time. The zone of linear dependence of a current on the application voltage (4-14V and a zone of nonlinear dependence of electrical conductivity at voltage more then 15 V for the given design of a measuring cell. The linear parts of characteristics can be used to develop the techniques for express train analysis of the volumetric contents of ethyl alcohol in a solution at low expenses of energy. It is established that the short-term influence of an electric field does not result in seen changes of initial parameters of a product.

  19. Romania needs a strategy for thermal energy

    Directory of Open Access Journals (Sweden)

    Leca Aureliu

    2015-06-01

    Full Text Available The energy sector in Romania consists of three sub-sectors: electricity, natural gas and heat. Among these, the sub-sector of thermal energy is in the most precarious situation because it has been neglected for a long time. This sub-sector is particularly important both due to the amount of final heat consumption (of over 50% of final energy consumption, and to the fact that it has a direct negative effect on the population, industry and services. This paper presents the main directions for developing a modern strategy of the thermal energy sub-sector, which would fit into Romania’s Energy Strategy that is still in preparation This is based on the author’s 50 years of experience in this field that includes knowledge about the processes and the equipment of thermal energy, expertise in the management and restructuring of energy companies and also knowledge of the specific legislation. It is therefore recommended, following the European regulations and practices, the promotion and upgrading of district heating systems using efficient cogeneration, using trigeneration in Romania, modernizing buildings in terms of energy use, using of renewable energy sources for heating, especially biomass, and modernizing the energy consumption of rural settlements.

  20. Managing Your Energy; An Energy Star Guide for Identifying Energy Savings in Manufacturing Plants

    NARCIS (Netherlands)

    Worrell, E.; Angelini, T.; Masanet, E.

    2010-01-01

    In the United States, industry spends over $100 billion annually to power its manufacturing plants. Companies also spend on maintenance, capital outlay, and energy services. Improving energy efficiency is vital to reduce these costs and increase earnings. Many cost-effective opportunities to reduce