WorldWideScience

Sample records for thermal effluents

  1. Agricultural utilization of industrial thermal effluents

    International Nuclear Information System (INIS)

    Guillermin, P.; Delmas, J.; Grauby, A.

    1976-01-01

    An assessment is made of the utilization of thermal effluent for agricultural purpose (viz. early vegetables, cereals, trees). Heated waters are being used in field experiments on soil heating, improvement of agricultural procedures and crop yields. Thermal pollution cannot be removed yet it is reduced to acceptable limits. New prospects are open to traditional agriculture, leading towards a more competitive industrial model [fr

  2. French studies on the thermal effluents of electric power plants

    International Nuclear Information System (INIS)

    Dezes-Cadiere, H.

    1976-01-01

    This report presents a synthesis of studies made in France in the thermal effluent field: thermal power plant cooling systems, transfer and dispersion of thermal effluents in the receptive media, effects of thermal effluents on water physicochemistry and biochemistry, effects of thermal effluents on aquatic ecosystems, and, possibilities of waste heat recovery with the view of utilization in agriculture, aquaculture and district heating. A catalogue of French organizations working or having data on thermal effluents is presented, as also an alphabetical list of the contacted persons. A bibliography of French documents concerning the previously mentioned studies is finally given (193 refs.) [fr

  3. Heat transfer from thermal effluent

    International Nuclear Information System (INIS)

    Czapski, U.H.; Mumford, W.

    1975-01-01

    Measurements of the turbulent fluxes of sensible heat and momentum, together with profiles of horizontal wind, temperature, and humidity (wet bulb) have been conducted above the thermal plume of the Nine Mile Point Nuclear plant near Oswego, New York on Lake Ontario. The spectral analysis of the data, obtained with sonic anemometer and ultrafast thermocouples, reveals the importance of microthermals and similar features for the transport of heat. Temperature variance spectra and the cospectra wT and uw show distinct deviations from the -5/3 Kolmogorov law in the inertial subrange, suggesting a high input of energy in the eddy frequency range between 0.01 and 1 Hz. It is shown that microthermals in this frequency range are also responsible for a large portion of the momentum transport. 46 refs

  4. Handling effluent from nuclear thermal propulsion system ground tests

    International Nuclear Information System (INIS)

    Shipers, L.R.; Allen, G.C.

    1992-01-01

    A variety of approaches for handling effluent from nuclear thermal propulsion system ground tests in an environmentally acceptable manner are discussed. The functional requirements of effluent treatment are defined and concept options are presented within the framework of these requirements. System concepts differ primarily in the choice of fission-product retention and waste handling concepts. The concept options considered range from closed cycle (venting the exhaust to a closed volume or recirculating the hydrogen in a closed loop) to open cycle (real time processing and venting of the effluent). This paper reviews the different methods to handle effluent from nuclear thermal propulsion system ground tests

  5. Effluent treatment options for nuclear thermal propulsion system ground tests

    International Nuclear Information System (INIS)

    Shipers, L.R.; Brockmann, J.E.

    1992-01-01

    A variety of approaches for handling effluent from nuclear thermal propulsion system ground tests in an environmentally acceptable manner are discussed. The functional requirements of effluent treatment are defined and concept options are presented within the framework of these requirements. System concepts differ primarily in the choice of fission-product retention and waste handling concepts. The concept options considered range from closed cycle (venting the exhaust to a closed volume or recirculating the hydrogen in a closed loop) to open cycle (real time processing and venting of the effluent). This paper reviews the strengths and weaknesses of different methods to handle effluent from nuclear thermal propulsion system ground tests

  6. Diversity of marine invertebrates in a thermal effluent

    International Nuclear Information System (INIS)

    Logan, D.T.; Maurer, D.

    1975-01-01

    Invertebrates were collected at four sites in the Indian River and Indian River Bay in Delaware to study the effects of thermal effluents from a steam-generating plant. A list of species of anemones, nemerteans, annelids, molluscs, and crustaceans is presented. Differences in species composition, an increase in relative numbers of a pollution indicator organism, and reduction in species number and in the total number of organisms in the effluent were noted. The period of highest diversity corresponded to that of the lowest numbers of species and individuals and highest effluent temperatures. (U.S.)

  7. Effluent treatment for nuclear thermal propulsion ground testing

    Science.gov (United States)

    Shipers, Larry R.

    1993-01-01

    The objectives are to define treatment functions, review concept options, discuss PIPET effluent treatment system (ETS), and outline future activities. The topics covered include the following: reactor exhaust; effluent treatment functions; effluent treatment categories; effluent treatment options; concept evaluation; PIPETS ETS envelope; PIPET effluent treatment concept; and future activities.

  8. Testing for Nuclear Thermal Propulsion Systems: Identification of Technologies for Effluent Treatment in Test Facilities

    Data.gov (United States)

    National Aeronautics and Space Administration — Key steps to ensure identification of relevant effluent treatment technologies for Nuclear Thermal Propulsion (NTP) testing include the following. 1. Review of...

  9. Periphyton crops and productivity in a reactor thermal effluent

    International Nuclear Information System (INIS)

    Tilly, L.J.

    1975-01-01

    Samples of periphyton grown for two weeks on microscope slides in surface waters of the reactor cooling reservoir, Par Pond, were examined for differences in species composition, diversity, standing crop, and 14 C uptake relatable to 7 positions in the thermal effluent. For stations which differed in average temperature by less than 5 0 C, weight specific productivity differed by a factor of 7. Periphyton biomass differed more than fivefold between stations 5.5 0 C apart. For most incubation intervals, both weight specific productivity and accumulated crop correlated highly with the average growing temperature, but slopes of regressions from consecutive periods often differed greatly while species composition and temperauture regime changed only slightly. Recent experiments indicate that observed differences may be due to interactions between nutrients and temperatures. (U.S.)

  10. Potential impact of thermal effluents from Chongqing Fuling nuclear power plant to the Three Gorges Reservoir

    International Nuclear Information System (INIS)

    Han Baohua; Li Jianguo; Ma Binghui; Zhang Yue; Sun Qunli; Hu Yuping

    2012-01-01

    This study is based on the hydrological data near Chongqing Fuling Nuclear Power Plant along the Yangtze River, the present situation of the ecological environment of the Three Gorges Reservoir and the predicted results of thermal effluents from Chongqing Fuling Nuclear Power Plant. The standards of cooling water and the thermal tolerances indexes of aquatic organisms were investigated. The effects of thermal effluents on aquatic organisms were analyzed. The potential impact of Chongqing Fuling nuclear power plant to the Three Gorges Reservoir was explained. The results show that in the most adverse working conditions, the surface temperature near the outfall area is not more than 1℃, the temperature of thermal effluents do not exceed the suitable thermal range of fish breeding, growth and other thermal tolerances indexes. Thermal effluents from nuclear power plant have no influence about fish, plankton and benthic organisms in the Three Gorges Reservoir. (authors)

  11. Thermal effluents from nuclear power plant influences species distribution and thermal tolerance of fishes in reservoirs

    International Nuclear Information System (INIS)

    Pal, A.K.; Das, T.; Dalvi, R.S.; Bagchi, S.; Manush, S.M.; Ayyappan, S.; Chandrachoodan, P.P.; Apte, S.K.; Ravi, P.M.

    2007-01-01

    During electricity generation water bodies like reservoir act as a heat sink for thermal effluent discharges from nuclear power plant. We hypothesized that the fish fauna gets distributed according to their temperature preference in the thermal gradient. In a simulated environment using critical thermal methodology (CTM), we assessed thermal tolerance and metabolic profile of fishes (Puntius filamentosus, Parluciosoma daniconius, Ompok malabaricus, Mastacembelus armatus, Labeo calbasu, Horabragrus brachysoma, Etroplus suratensis, Danio aequipinnatus and Gonoproktopterus curmuca) collected from Kadra reservoir in Karnataka state. Results of CTM tests agrees with the species abundance as per the temperature gradient formed in the reservoir due to thermal effluent discharge. E. suratensis and H. brachysoma) appear to be adapted to high temperature (with high CTMax and CTMin values) and are in abundance at point of thermal discharge. Similarly, P. daniconius, appear to be adapted to cold (low CTM values) is in abundance in lower stretches of Kadra reservoir. Overall results indicate that discharge form nuclear power plant influences the species biodiversity in enclosed water bodies. (author)

  12. Effects of a thermal effluent on the reproduction of the American oyster

    International Nuclear Information System (INIS)

    Tinsman, J.C.; Tinsman, S.G.; Maurer, D.

    1976-01-01

    Oysters were sampled from September 1970 to September 1972 from two stations in Indian River Bay, Delaware, for histological examination. Station 1 (control) was located near the intake of the Delmarva Power and Light Company's fossil-fuel plant in Millsboro, Del. Station 2 (effluent) was 2.5 km east of the plant at the mouth of Island Creek. A combination of classical and quantitative methods was used to document changes in the developmental cycle of oysters resulting from the influence of a thermal effluent. Oysters in the effluent showed precocious gonadal development during the spring, but the time of maximum ripeness and spawning activity was the same at both stations. An extension of the spawning season for several weeks in September was noted for oysters in the effluent. During 1972, oysters in the thermal effluent showed a significantly lower level of gonadal development than did controls. Since this season of decreased reproductive amplitude corresponds with a period of high mortalities among effluent oysters, it seems likely that these oysters were thermally stressed, requiring more energy for maintenance and leaving less available for reproduction

  13. Effects of a thermal effluent on the ostracods of Par Pond, South Carolina

    International Nuclear Information System (INIS)

    Bowen, M.

    1976-01-01

    The effects of a thermal effluent on the distribution and abundance of freshwater ostracods were investigated. Hot and cold water and thermal recovery sites were sampled for their ostracod fauna, using both tow and core methods. An unusual assemblage of both tropical and temperate ostracods was collected. Neither high maximum nor high minimum temperatures had an effect on total numbers of ostracods per sample, but high minimum temperatures were correlated with low species diversity. Variations in the seasonal cycles of ostracods were related to temperature differences. Thermal stresses may have indirectly affected the ostracod population by eliminating rooted vegetation

  14. Effluent Containment System for space thermal nuclear propulsion ground test facilities

    International Nuclear Information System (INIS)

    1995-08-01

    This report presents the research and development study work performed for the Space Reactor Power System Division of the U.S. Department of Energy on an innovative ECS that would be used during ground testing of a space nuclear thermal rocket engine. A significant portion of the ground test facilities for a space nuclear thermal propulsion engine are the effluent treatment and containment systems. The proposed ECS configuration developed recycles all engine coolant media and does not impact the environment by venting radioactive material. All coolant media, hydrogen and water, are collected, treated for removal of radioactive particulates, and recycled for use in subsequent tests until the end of the facility life. Radioactive materials removed by the treatment systems are recovered, stored for decay of short-lived isotopes, or packaged for disposal as waste. At the end of the useful life, the facility will be decontaminated and dismantled for disposal

  15. Thermophillic and thermotolerant fungi isolated from the thermal effluent of nuclear power generating reactors

    International Nuclear Information System (INIS)

    Rippon, J.W.; Gerhold, R.; Heath, M.

    1980-01-01

    Over a period of a year, samples of water, foam, microbial mat, soil and air were obtained from areas associated with the cooling canal of a nuclear power station. The seventeen sample sites included water in the cooling canal that was thermally enriched and soil and water adjacent to, up-stream, downstream and at a distance from the generator. Air samples were taken at the plant and at various disstances from the plant. Fifty-two species of thermotolerant and thermophilic fungi were isolated. Of these, eleven species are grouped as opportunistic Mucorales or opportunistic Aspergillus sp. One veterinary pathogen was also isolated (Dactylaria gallopara). The opportunistic/pathogenic fungi were found primarily in the intake bay, the discharge bay and the cooling canal. Smaller numbers were obtained at both upstream and downstream locations. Soil samples near the cooling canal reflected an enrichment of thermophilous organisms, the previously mentioned opportunistic Mucorales and Aspergillus spp. Their numbers were found to be greater than that usually encountered in a mesophilic environment. However, air and soil samples taken at various distances from the power station indicated no greater abundance of these thermophilous fungi than would be expected from a thermal enriched environment. Our results indicate that there was no significant dissemination of thermophilous fungi from the thermal enriched effluents to the adjacent environment. These findings are consistent with the results of other investigators. (orig.)

  16. Delineation of thermal effluents discharged into tropical waters around Puerto Rico by aerial infrared scanning

    International Nuclear Information System (INIS)

    Wood, E.D.

    1975-01-01

    Aerial infrared scanning offers a versatile tool with which to monitor thermal discharges and a rapid method of detecting extraneous discharges, whose temperatures differ from the ambient waters. Knowledge of the extent and distribution of thermal effluents is necessary to assist in determining the effects of the added heat upon biota of the region. An AGA Model 680 Thermovision infrared scanner with a 45 0 lens was mounted in a Cessna 182, and flown at altitudes of 600 to 2000 m during night and twilight hours. The detector was InSb, cooled with liquid nitrogen and sensitive to the range 2 to 5.6 μm. The picture was originally displayed on a color monitor which assigned ten arbitrary colors to shades of gray on the control unit. Isotherms have been assigned using coincidental surface measurements made with a thermometer, read to the nearest 0.1 0 C. The data were then recorded on film. Ranges were set at 2 0 C and 5 0 C, common sensitivities were 0.2 0 C and 0.5 0 C, respectively. More recently, the data have been recorded on magnetic tapes with a Sabre III instrumentation tape recorder. Observed data have been compared to predictions made using the Pritchard Plume Model. Anomalies can be explained by boundary, wind, and tidal effects. (U.S.)

  17. Effect of thermal effluents from the Savannah River Plant on leaf decomposition rates in onsite creeks and the Savannah River

    International Nuclear Information System (INIS)

    Sadowski, P.W.; Matthews, R.A.

    1986-06-01

    Sweet gum and sycamore leaf packs were packs were placed in a thermally stressed, a post-thermal, and an ambient stream located on the Savannah River Plant, South Carolina, and in the Savannah River below the mouth of each stream. Processing rates for the leaf packs were determined over a 77-day period from December 1982 to March 1983. Due to inundation of the sampling sites by river flooding, temperatures in the stream receiving thermal effluent were reduced after day 24. Sweet gum leaves decomposed considerably faster than did sycamore leaves, particularly in the thermal creek. An exponential decay model was used to demonstrate significant differences in loss of ash-free dry weight from leaf packs in thermally stressed and nonthermal creeks. Differences in leaf processing rates between creek sites were greatest during periods of therma stress. Within each leaf species, leaf processing rates were not significantly different between nonthermal sites, nor between sites in the Savannah River

  18. A Preliminary Investigation of the Effect of Ocean Thermal Energy Conversion (OTEC Effluent Discharge Options on Global OTEC Resources

    Directory of Open Access Journals (Sweden)

    Gérard Nihous

    2018-03-01

    Full Text Available A simple algorithm previously used to evaluate steady-state global Ocean Thermal Energy Conversion (OTEC resources is extended to probe the effect of various effluent discharge methodologies. It is found that separate evaporator and condenser discharges potentially increase OTEC net power limits by about 60% over a comparable mixed discharge scenario. This stems from a relatively less severe degradation of the thermal resource at given OTEC seawater flow rates, which corresponds to a smaller heat input into the ocean. Next, the most practical case of a mixed discharge into the mixed layer is found to correspond to only 80% of the so-called baseline case (mixed discharge at a water depth of initial neutral buoyancy. In general, locating effluent discharges at initial neutral-buoyancy depths appears to be nearly optimal in terms of OTEC net power production limits. The depth selected for the OTEC condenser effluent discharge, however, has by far the greatest impact. Clearly, these results are preliminary and should be investigated in more complex ocean general circulation models.

  19. Criticality safety issues arising from the treatment of liquid effluent streams from the reprocessing of thermal oxide fuel

    International Nuclear Information System (INIS)

    Thorne, P.R.; Farrington, L.M.

    1991-01-01

    The BNFL THORP plant will reprocess irradiated oxide fuel from thermal reactors to recover plutonium dioxide and uranium trioxide in a pure form. A consequence of the reprocessing is that several liquid effluent streams are produced which can contain residual fissile material. Generally, the treatment of these effluent streams is carried out in large vessels which are not geometrically favourable with regard to nuclear safety. This is possible because the concentration of fissile material in solution is far less than the safely subcritical infinite sea concentrations. The situation is complicated by the presence of precipitated solids in some vessels and crud layers in others. Experimental measurements have been used to characterise these solids in order to extend the usual safe limits, and to provide an acceptable operating regime. Based on the experimental characterisation of the solids, the neutronics computer codes WIMS and MONK have been used to determine the optimum possible conditions existing, and to determine the safe fissile mass limits for these systems. The limits which are derived have been used to provide alarm and trip levels for instrumentation which has been employed in a novel way. It has been shown that the plant can be operated successfully and remains acceptably safe taking into account the presence of solids in the liquid effluent streams. (author)

  20. Thermal tolerances of fish from a reservoir receiving heated effluent from a nuclear reactor

    International Nuclear Information System (INIS)

    Holland, W.E.; Smith, M.H.; Gibbons, J.W.; Brown, D.H.

    1974-01-01

    The heat tolerances of bluegill (Lepomis macrochirus) subjected to heated effluent from a nuclear reactor was compared with those of bluegill living at normal temperatures. Three of the four study areas were located in the Par Pond reservoir system on the Savannah River Plant near Aiken, South Carolina. Results shown that at least one species of warm-water fish can adjust to elevated aquatic temperatures in a natural environment by becoming more tolerant. (U.S.)

  1. Assessment of potential impact of the Clinch River Breeder Reactor Plant thermal effluent on the Watts Bar Reservoir striped bass population

    International Nuclear Information System (INIS)

    Heuer, J.H.; McIntosh, D.; Ostrowski, P.; Tomljanovich, D.A.

    1983-11-01

    This report is an assessment of potential adverse impact to striped bass (Morone saxatilis) in Watts Bar Reservoir caused by thermal effluent from operation of the Clinch River Breeder Reactor Plant (CRBRP). The Clinch River arm of Watts Bar Reservoir is occupied by adult striped bass during the warmest months of the year. Concern was raised that operation of the CRBRP, specifically thermal discharges, could conflict with management of striped bass. In all cases examined the thermal plume becomes nearly imperceptible within a short distance from the discharge pipe (about 30 ft [10 m]) compared to river width (about 630 ft [190 m]). Under worst case conditions any presence of the plume in the main channel (opposite side of the river from the discharge) will be confined to the surface layer of the water. An ample portion of river cross sections containing ambient temperature water for passage or residence of adult striped bass will always be available in the vicinity of this thermal effluent. Although a small portion of river cross section would exceed the thermal tolerance of striped bass, the fish would naturally avoid this area and seek out adjacent cooler water. Therefore, it is concluded the CRBRP thermal effluent will not significantly affect the integrity of the striped bass thermal refuge in the Clinch River arm of Watts Bar Reservoir. At this time there is no need to consider alternative diffuser designs and thermal modeling. 8 references, 3 figures, 2 tables

  2. Improvement of thermal exchange between feedstock and effluent in a hydrocarbon processing unit under hydrogen atmosphere by partial recycling of the product

    Energy Technology Data Exchange (ETDEWEB)

    Orieux, A.

    1990-01-19

    Heat exchange is improved in light naphta hydroisomerization and catalytic reforming by recirculation of a part of the product in the thermal exchange zone at a temperature higher than the dew point of the effluent under hydrogen atmosphere and preferentially as a temperature lower than the temperature of the recycled product.

  3. The feasibility of agricultural uses of thermal effluent from Glace Bay heavy water plant

    International Nuclear Information System (INIS)

    Iverson, S.L.; Puttagunta, V.R.; Meek, K.D.; Chisholm, K.L.

    1978-04-01

    The costs and practicality of pumping effluent water from the GBHWP outfall channel about 500 m to a distribution point, distributing it to up to 25 acres of greenhouses, transferring the heat to the greenhouse air, returning the water to the effluent channel and providing a back-up heat supply were examined. The system described will not interfere with GBHWP operations and can provide a good environment for plant growth at a very attractive price. If a system was designed to serve a 5-acre greenhouse industry, it would cost $18 280 to heat each acre of greenhouse per year ($1.76/GJ), while a system servicing 25 acres could heat greenhouses for only $11 824 per acre per year ($1.14/GJ). This can be compared with the average of $20 000 per acre for fuel alone, paid by Nova Scotia growers in 1975, or the $25 000 per acre per year ($2.40/GJ) calculated in this study as the cost for Bunker C fuel alone at July 1977 prices. The low heating costs possible using waste heat should allow a viable greenhouse industry to be established at Glace Bay, Nova Scotia, and it is recommended that a demonstration greenhouse be constructed to verify the results of this study and demonstrate the technology to potential growers

  4. Response of mole crab, Emerita emeritus to the thermal effluents from the Madras Atomic Power Station at Kalpakkam

    International Nuclear Information System (INIS)

    Subramoniam, T.; Munuswamy, N.; Israel, Sunil; Sathish, R.; Venugopalan, V.P.

    2007-01-01

    Mole crabs belonging to the genus Emerita are exclusively inhabitants of exposed wave washed sandy beaches in certain temperate and tropical seas. Its sedentary adult life and a primitive filter-feeding behavior make this intertidal crab an excellent indicator species for monitoring anthropogenic impact. Hence, this sand crab has been used to determine the effect of elevated temperature (rT) arising out of the thermal effluent from the Madras Atomic Power Station (MAPS), Kalpakkam with special reference to the intertidal fauna. Since Emerita exhibits limited capacity to move from their place of habitation, an analysis of the population structure of Emerita emeritus in the Kalpakkam coast including the impacted and the adjoining control sandy beaches on either side of the mixing point in the vicinity of the power plant was done. The data indicate that in the impact zone having an elevated seawater temperature of <35 deg C, the crab is completely absent. However, as we move away from the impact zone, with normalization of seawater temperature, Emerita move to safer areas on either side of the impact zone. Thus, the extensive field data on the distribution of mole crabs indicated that population structure is affected by the thermal plume, although the shifting positions of the mixing point (caused by northerly and southerly long shore currents) allowed decolonization of Emerita due to transmigration in positions that were earlier mixing points. This paper also describes a complete larval development of Emerita emeritus in the laboratory. Different life stages of E. emeritus were subjected to various power plant stressors to determine their varying responses. The expression of heat shock protein (hsp) in the gill tissue of the adult crabs was also observed when the crabs were exposed to elevated temperatures (35 deg C). However, no expression of heat shock proteins was observed when the crabs were subjected to chlorine stress. (author)

  5. Effects of thermal effluents from the Unterweser reactor (KKU) on biocenoses in the Unterweser. Pt. 3

    International Nuclear Information System (INIS)

    Vobach, M.; Feldt, W.

    1991-01-01

    Between August 1975 and November 1982, the influence of thermal pollution in the biocenosis of the Unterweser from cooling water dischanged by the Unterweser reactor was investigated. The state of the parts of the river not yet stressed by cooling water is compared with conditions after the start-up of the reactor (September 1978). The seasonal cycle of water temperature has not changed after the start-up as compared to the time before. A warming of the river water because of cooling water discharged from the reactor is recognizable in the area immediately surrounding the month of the discharge system. Benthal investigations show the composition of species and number of individuals to be unchanged after the start-up of the reactor. Phytoplankton, too, continues to have its population maximum in May and August. Zooplankton, being present abundantly and in clusters, has retained its original composition of species. Now as before the reactor's start-up, flounder, smelt, stickleback, sprat and gudgeon which between them account for 97 per cent of the total catch, continue to be the five major fish species. Variations in the composition of catch are not to be explained by changes of temperature. The slight temperature increase does not modify the spectrum of species; there is no temperature stimulus. The seasonal cycle of water temperatures, which are important for a diapause, i.e. a slowing in the developmental cycle with a reduced metabolism, thus safeguarding the survival of certain species, do continue to occur. Any observed changes are to be interpreted as expressions of longer-term biological cycles. (orig./BBR) [de

  6. Aerial and liquid effluent treatment in BNFL's Thermal Oxide Reprocessing Plant (THORP)

    International Nuclear Information System (INIS)

    Hudson, P.I.; Buckley, C.P.

    1996-01-01

    British Nuclear Fuels plc (BNFL) completed construction of its Thermal Oxide Reprocessing Plant (THORP) at Sellafield in 1992, at a cost of pound 1,850M. After Government and Regulatory approval, active commissioning was initiated in January 1994. Since then, the whole of the plant has been progressively commissioned and moved towards full operational status. From the outset, the need to protect the workforce, the public and the environment in general from the plant's discharges was clearly recognised. The design intent was to limit radiation exposure of members of the general public to 'As Low as Reasonably Practicable' (ALARP). Furthermore no member of the most highly exposed (critical) group should receive an annual dose exceeding 50 microsieverts from either the aerial or marine discharge routes. This paper describes how the design intent has been met, concentrating mainly on aerial discharges. It describes the sub-division of the plant's ventilation system into a number of separate systems, according to the volume and source of the arising and the complexity of the treatment process. The dissolver off-gas, central off-gas, cell and building ventilation systems are described, together with the development programme which was undertaken to address the more demanding aspects of the performance specification. This ranged from small-scale experiments with irradiated fuel to inactive pilot plant trials and full-scale plant measurements. In addition wind tunnel tests were employed to assist dispersion modelling of the gases as they are discharged from the THORP stack. All the resulting information was then used, with the aid of mathematical models, in the design of an off-gas treatment system which could achieve the overall goal. (J.P.N.)

  7. Integration of remotely sensed data and hydrodynamic modeling into a GIS to assess the impacts of thermal effluent in an estuary

    International Nuclear Information System (INIS)

    Mustard, J.F.; Sen, A.; Swanson, C.; Mendelsohn, D.

    1997-01-01

    A project to assess the effects of thermal effluent from a electrical generating facility on an estuary is described. The project is designed to integrate remote sensing observations with in situ field data and a computer model system to provide continuous, estuary-wide predictions of the effluent plume location and configurations. Remote sensing data was acquired over the ebb tide cycle by an aircraft-mounted multi-channel imaging spectrometer. A ground truth field program measured water temperature on a series of transects during the overflights. Moored instruments continuously acquired data on currents, salinity, temperature and dissolved oxygen before, during and after the day of the overflight. A hydrodynamic model was used to predict the three-dimensional structure of the currents, temperature and salinity in the estuary. A Lagrangian particle-based trajectory model was used to predict the small scale surface features seen in the overflight images. Results indicate that such a system can provide useful data in support of analyses of thermal effects of the ecology of estuarine environments

  8. Avoidance of thermal effluent by juvenile chinook salmon (Oncorhynchus tshowytscha) and its implications in waste heat management

    International Nuclear Information System (INIS)

    Gray, R.H.

    1977-03-01

    Knowledge of behavioral responses of aquatic organisms to thermal discharges at power plants is essential to evaluate thermal exposure and subsequent effects on survival and ecological success. Instantaneous responses of juvenile salmon that encountered a simulated river-thermal plume interface were assessed in a model raceway with a thermal discharge. Fish movement and response to the discharge were recorded on videotape. Juvenile chinook salmon (Oncorhynchus tshawytscha) tested under three discharge conditions (no plume, ambient plume and heated plume) avoided plume temperatures greater than 9 to 11 0 C above ambient. Fish occasionally oriented to the discharge current, but were not attracted to the thermal component of the plume when plume ΔT's were below the avoidance level of 11 0 C. Fish did not pass to the lower end of the raceway when plume ΔT exceeded 9 to 11 0 C. The responses noted in our experiments suggest organismic behavior may prevent juvenile salmon in nature from experiencing lethal conditions from thermal discharges and have application in waste heat management and utilization

  9. Effluent Guidelines

    Science.gov (United States)

    Effluent guidelines are national standards for wastewater discharges to surface waters and municipal sewage treatment plants. We issue the regulations for industrial categories based on the performance of treatment and control technologies.

  10. Catalytic thermal treatment (catalytic thermolysis) of a rice grain-based biodigester effluent of an alcohol distillery plant.

    Science.gov (United States)

    Prajapati, Abhinesh Kumar; Chaudhari, Parmesh Kumar; Mazumdar, Bidyut; Choudhary, Rumi

    2015-01-01

    The catalytic thermolysis (CT) process is an effective and novel approach to treat rice grain-based biodigester effluent (BDE) of the distillery plant. CT treatment of rice grain-based distillery wastewater was carried out in a 0.5 dm(3) thermolytic batch reactor using different catalysts such as CuO, copper sulphate and ferrous sulphate. With the CuO catalyst, a temperature of 95°C, catalyst loading of 4 g/dm(3) and pH 5 were found to be optimal, obtaining a maximum chemical oxygen demand (COD) and colour removal of 80.4% and 72%, respectively. The initial pH (pHi) was an important parameter to remove COD and colour from BDE. At higher pHi (pH 9.5), less COD and colour reduction were observed. The settling characteristics of CT-treated sludge were also analysed at different temperatures. It was noted that the treated slurry at a temperature of 80°C gave best settling characteristics. Characteristics of residues are also analysed at different pH.

  11. Production of demineralized water for use in thermal power stations by advanced treatment of secondary wastewater effluent.

    Science.gov (United States)

    Katsoyiannis, Ioannis A; Gkotsis, Petros; Castellana, Massimo; Cartechini, Fabricio; Zouboulis, Anastasios I

    2017-04-01

    The operation and efficiency of a modern, high-tech industrial full-scale water treatment plant was investigated in the present study. The treated water was used for the supply of the boilers, producing steam to feed the steam turbine of the power station. The inlet water was the effluent of municipal wastewater treatment plant of the city of Bari (Italy). The treatment stages comprised (1) coagulation, using ferric chloride, (2) lime softening, (3) powdered activated carbon, all dosed in a sedimentation tank. The treated water was thereafter subjected to dual-media filtration, followed by ultra-filtration (UF). The outlet of UF was subsequently treated by reverse osmosis (RO) and finally by ion exchange (IX). The inlet water had total organic carbon (TOC) concentration 10-12 mg/L, turbidity 10-15 NTU and conductivity 3500-4500 μS/cm. The final demineralized water had TOC less than 0.2 mg/L, turbidity less than 0.1 NTU and conductivity 0.055-0.070 μS/cm. Organic matter fractionation showed that most of the final DOC concentration consisted of low molecular weight neutral compounds, while other compounds such as humic acids or building blocks were completely removed. It is notable that this plant was operating under "Zero Liquid Discharge" conditions, implementing treatment of any generated liquid waste. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Effluent standards

    Energy Technology Data Exchange (ETDEWEB)

    Geisler, G C [Pennsylvania State University (United States)

    1974-07-01

    At the conference there was a considerable interest in research reactor standards and effluent standards in particular. On the program, this is demonstrated by the panel discussion on effluents, the paper on argon 41 measured by Sims, and the summary paper by Ringle, et al. on the activities of ANS research reactor standards committee (ANS-15). As a result, a meeting was organized to discuss the proposed ANS standard on research reactor effluents (15.9). This was held on Tuesday evening, was attended by members of the ANS-15 committee who were present at the conference, participants in the panel discussion on the subject, and others interested. Out of this meeting came a number of excellent suggestions for changes which will increase the utility of the standard, and a strong recommendation that the effluent standard (15.9) be combined with the effluent monitoring standard. It is expected that these suggestions and recommendations will be incorporated and a revised draft issued for comment early this summer. (author)

  13. State-of-the-art of the utilization of thermal effluents and its future R and D plannings

    International Nuclear Information System (INIS)

    Iituka, Teiji; Okano, Toshiaki; Wada, Akira

    1987-01-01

    Thermal and nuclear power plants have been constructed in coastal areas in Japan, and use large quantity of seawater for cooling condensers, consequently, they discharge warm drainage which is about 7 deg C higher than seawater. The object of this paper is to study on the method of expanding the use of warm drainage by collecting the knowledge on its actual use from the papers published so far. The number of the papers collected was 153. The main fields of actually using warm drainage are marine nurseries using seawater in Japan and greenhouse heating using fresh water in foreign countries. Seven nuclear power plants and 14 thermal power plants in Japan had the facilities of marine nurseries as of June, 1986. The quantity of warm drainage used was 0.667 m 3 -s (0.05 %) in nuclear power plants and 1.182 m 3 -h in thermal power plants. In Japan, most of warm drainage is the seawater only 7 deg C higher than the original seawater, therefore the application is limited. In order to expand the application, it is important to devise the system utilizing the energy of flow in addition to its heat. It was suggested that the expansion of application would be possible in the development and improvement of fishing grounds using large quantity of warm drainage. (Kako, I.)

  14. Intensive aquaculture of tilapia (Sarotherodon niloticus) in the thermal effluents of a nuclear power plant in Belgium

    International Nuclear Information System (INIS)

    Melard, Ch.; Philippart, J.C.

    1981-01-01

    This paper presents the results of three years of experiments in cultivating S. niloticus in the cooling waters of the nuclear power station at Tihange on the Meuse. The research station infrastructure consists of three earthen ponds measuring 150m 2 (volume: 200m 3 ) and 16 fibreglass tanks of 4m 2 (2m 3 ). These are fed by a pumping system (70m 3 /h) at the outlet point of the power station condenser. A regulation system ensures that the feed-water is kept at a safe thermal level (17-32 deg. C). The Meuse has a high biological productivity potential at Tihange; there is no chemical pollution of any significance, although moderate organic pollution exists. The thermal conditions in the river make it possible to count on nine months (March to December) during which the average utilizable water temperature for tilapia culture exceeds 20 deg. C. Under conditions of intensive-tank culture, it was possible to maintain a maximum biomass (with 150g fish) of 120kg/m 3 of tank with a water renewal rate of about 3.5 times per hour (loading: 2.1kg/liter per minute). A figure is provided showing the relation to weight of oxygen consumption and optimal loading at a temperature of 30-32 deg. C. The highest yields recorded are 21.1q/m 3 per hour and 25.7kg/m 3 of tank/month; with an average yield of 12g/m 3 per hour, a volume of 85m 3 of heated water is required to produce 1kg of S. niloticus from 20g of male fry. The fish are suitable for marketing (trial offer to restaurants) if they weigh 300-350g. Analysis shows that their heavy metals and radionuclide content is below the level permitted by law. (author)

  15. Facility effluent monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Gleckler, B.P.

    1995-06-01

    This section of the 1994 Hanford Site Environmental Report summarizes the facility effluent monitoring programs and provides an evaluation of effluent monitoring data. These evaluations are useful in assessing the effectiveness of effluent treatment and control systems, as well as management practices.

  16. Comparative Study of Leachate Characteristics of Pond Ash from Long-Term Leaching and Ash Pond Disposal Point Effluent from Chandrapura Thermal Power Station, India

    Directory of Open Access Journals (Sweden)

    Ritesh Kumar

    2010-01-01

    Full Text Available The present paper deals with the leaching characteristics of coal combustion residues from chandrapura thermal power station, Jharkhand, India. The study was made under the laboratory as well as the field condition. From the laboratory study conducted so far it is hereby concluded that the leachates of coal combustion residues from chandrapura thermal power station with respect to potentiometric and trace elements analysis are within the permissible limits as per Indian Standards (IS:2490. From the study it is also found that the elements such as arsenic, boron, nickel, etc. could not be detected. The discharge point leachate also does not pose any environmental problem from the point of view of leaching of trace and/or toxic elements as per IS: 2490.

  17. modelling effluent assimila modelling effluent assimilat modelling

    African Journals Online (AJOL)

    eobe

    G EFFLUENT ASSIMILATIVE CAPACITY OF IKPOBA RIVE. BENIN CITY, NIGERIA ... l purposes to communities rse such as ... treat in order for it to meet the aforeme of the communities. It is therefore i ..... Substituting and integrating yields the following equations ..... Purification Potentials of Small Tropical Urban. Stream: A ...

  18. INEEL Liquid Effluent Inventory

    Energy Technology Data Exchange (ETDEWEB)

    Major, C.A.

    1997-06-01

    The INEEL contractors and their associated facilities are required to identify all liquid effluent discharges that may impact the environment at the INEEL. This liquid effluent information is then placed in the Liquid Effluent Inventory (LEI) database, which is maintained by the INEEL prime contractor. The purpose of the LEI is to identify and maintain a current listing of all liquid effluent discharge points and to identify which discharges are subject to federal, state, or local permitting or reporting requirements and DOE order requirements. Initial characterization, which represents most of the INEEL liquid effluents, has been performed, and additional characterization may be required in the future to meet regulations. LEI information is made available to persons responsible for or concerned with INEEL compliance with liquid effluent permitting or reporting requirements, such as the National Pollutant Discharge Elimination System, Wastewater Land Application, Storm Water Pollution Prevention, Spill Prevention Control and Countermeasures, and Industrial Wastewater Pretreatment. The State of Idaho Environmental Oversight and Monitoring Program also needs the information for tracking liquid effluent discharges at the INEEL. The information provides a baseline from which future liquid discharges can be identified, characterized, and regulated, if appropriate. The review covered new and removed buildings/structures, buildings/structures which most likely had new, relocated, or removed LEI discharge points, and at least 10% of the remaining discharge points.

  19. Using temperature and time criteria to control the effectiveness of continuous thermal sanitation of piggery effluent in terms of set microbial indicators.

    Science.gov (United States)

    Cunault, C; Pourcher, A M; Burton, C H

    2011-12-01

    To determine the minimal conditions (temperature-time), necessary to achieve set sanitation targets for selected microbial indicators during the continuous thermal treatment of pig slurry. The effectiveness of thermal treatment between 55 and 96°C was studied using Escherichia coli, enterococci, sulfite-reducing Clostridia (SRC), mesophilic culturable bacteria (MCB), F+-specific and somatic phages. Identification of SRC and MCB was performed using 16S rRNA gene analysis. Ten minutes at 70°C or 1 h at 60°C was sufficient to reduce the vegetative bacteria by 4-5 log(10), but it had little effect on somatic phages nor on spore formers, dominated by Clostridium sp. At 96°C, somatic phages were still detected, but there was a reduction of 3.1 log(10) for SRC and of 1.4 log(10) for MCB. At 96°C, Clostridium botulinum was identified among the thermotolerant MCB. Only those hygienic risks relating to mesophilic vegetative bacteria can be totally eliminated from pig slurry treated at 60°C (60 min) or 70°C (cost treatment using heat recovery). However, even at 96°C, certain pathogens may persist. Journal of Applied Microbiology © 2011 The Society for Applied Microbiology. No claim to French Government works.

  20. Nuclear reactor effluent monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Minns, J.L.; Essig, T.H. [Nuclear Regulatory Commission, Washington, DC (United States)

    1993-12-31

    Radiological environmental monitoring and effluent monitoring at nuclear power plants is important both for normal operations, as well as in the event of an accident. During normal operations, environmental monitoring verifies the effectiveness of in-plant measures for controlling the release of radioactive materials in the plant. Following an accident, it would be an additional mechanism for estimating doses to members of the general public. This paper identifies the U.S. Nuclear Regulatory Commission (NRC) regulatory basis for requiring radiological environmental and effluent monitoring, licensee conditions for effluent and environmental monitoring, NRC independent oversight activities, and NRC`s program results.

  1. Nuclear reactor effluent monitoring

    International Nuclear Information System (INIS)

    Minns, J.L.; Essig, T.H.

    1993-01-01

    Radiological environmental monitoring and effluent monitoring at nuclear power plants is important both for normal operations, as well as in the event of an accident. During normal operations, environmental monitoring verifies the effectiveness of in-plant measures for controlling the release of radioactive materials in the plant. Following an accident, it would be an additional mechanism for estimating doses to members of the general public. This paper identifies the U.S. Nuclear Regulatory Commission (NRC) regulatory basis for requiring radiological environmental and effluent monitoring, licensee conditions for effluent and environmental monitoring, NRC independent oversight activities, and NRC's program results

  2. Genotoxicity of swine effluents.

    Science.gov (United States)

    Techio, V H; Stolberg, J; Kunz, A; Zanin, E; Perdomo, C C

    2011-01-01

    This study aimed at the investigation of genotoxic effects of swine effluents from different stages of a treatment system for swine wastes through bioassay of stamen hairs and micronuclei in Tradescantia (clone BNL 4430). No significant differences (p≥0.05) regarding the genic mutations were found in the bioassay of stamen hairs, independently of the effluent analysed. For the genotoxicity test with micronuclei, the plants exposed to raw wastes, to sludge, and to effluent of the biodigester have presented higher rates of chromosomal damages (micronuclei), with significant differences in relation to the control group and other effluent of the waste treatment system (p≤0.05). The association between the chemical parameters and the genotoxicity data have shown that the variables COD and TKN have presented significant correlation (p≤0.05) with the number of mutagenic events in the tetrads.

  3. Treated Effluent Disposal Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Treated non-hazardous and non-radioactive liquid wastes are collected and then disposed of through the systems at the Treated Effluent Disposal Facility (TEDF). More...

  4. Liquid Effluent Retention Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Liquid Effluent Retention Facility (LERF) is located in the central part of the Hanford Site. LERF is permitted by the State of Washington and has three liquid...

  5. CONCAWE effluent speciation project

    Energy Technology Data Exchange (ETDEWEB)

    Leonards, P.; Comber, M.; Forbes, S.; Whale, G.; Den Haan, K.

    2010-09-15

    In preparation for the implementation of the EU REACH regulation, a project was undertaken to transfer the high-resolution analytical method for determining hydrocarbon blocks in petroleum products by comprehensive two-dimensional gas chromatography (GCxGC) to a laboratory external to the petroleum industry (Institute for Environmental Studies (IVM) of the VU University of Amsterdam). The method was validated and used for the analysis of petroleum hydrocarbons extracted from refinery effluents. The report describes the technology transfer and the approaches used to demonstrate the successful transfer and application of the GCxGC methodology from analysing petroleum products to the quantitative determination of hydrocarbon blocks in refinery effluents. The report describes all the methods used for all the determinations on the effluent samples along with an overview of the results obtained which are presented in summary tables and graphs. These data have significantly improved CONCAWE's knowledge of what refineries emit in their effluents. A total of 111 Effluent Discharge Samples from 105 CONCAWE refineries in Europe were obtained in the period June 2008 to March 2009. These effluents were analysed for metals, standard effluent parameters (including COD, BOD), oil in water, BTEX and volatile organic compounds. The hydrocarbon speciation determinations and other hydrocarbon analyses are also reported. The individual refinery analytical results are included into this report, coded as per the CONCAWE system. These data will be, individually, communicated to companies and refineries. The report demonstrates that it is feasible to conduct a research programme to investigate the fate and effects of hydrocarbon blocks present in discharged refinery effluents.

  6. Richards Bay effluent pipeline

    CSIR Research Space (South Africa)

    Lord, DA

    1986-07-01

    Full Text Available of major concern identified in the effluent are the large volume of byproduct calcium sulphate (phosphogypsum) which would smother marine life, high concentrations of fluoride highly toxic to marine life, heavy metals, chlorinated organic material... ........................ 9 THE RICHARDS BAY PIPELINE ........................................ 16 Environmental considerations ................................... 16 - Phosphogypsum disposal ................................... 16 - Effects of fluoride on locally occurring...

  7. Liquid effluent at Dounreay

    International Nuclear Information System (INIS)

    Sinclair, N.R.

    1995-01-01

    This short paper reviews the liquid effluent treatment at the Dounreay site. The significant reductions in volume and activity discharged from the site to the environment have been achieved over the many years of operation, and some of the techniques are highlighted. The Regulator interaction and the effect on the environment is discussed, while some of the requirements of the Regulator are presented. (author)

  8. The treatment of effluents

    International Nuclear Information System (INIS)

    Wormser, G.; Rodier, J.; Robien, E. de; Fernandez, N.

    1964-01-01

    For several years the French Atomic Energy Commission has been studying with interest problems presented by radio-active effluents. Since high activities have not yet received a definite solution we will deal only, in this paper, with the achievements and research concerning low and medium activity effluents. In the field of the achievements, we may mention the various effluent treatment stations which have been built in France; a brief list will be given together with an outline of their main new features. Thus in particular the latest treatment stations put into operation (Grenoble, Fontenay-aux-Roses, Cadarache) will be presented. From all these recent achievements three subjects will be dealt with in more detail. 1 - The workshop for treating with bitumen the sludge obtained after concentration of radionuclides. 2 - The workshop for treating radioactive solid waste by incineration. 3 - A unit for concentrating radio-active liquid effluents by evaporation. In the field of research, several topics have been undertaken, a list will be given. In most cases the research concerns the concentration of radionuclides with a view to a practical and low cost storage, a concentration involving an efficient decontamination of the aqueous liquids in the best possible economic conditions. For improving the treatments leading to the concentration of nuclides, our research has naturally been concerned with perfecting the treatments used in France: coprecipitation and evaporation. In our work we have taken into account in particular two conditions laid down in the French Centres. 1 - A very strict sorting out of the effluents at their source in order to limit in each category the volume of liquid to be dealt with. 2 - The necessity for a very complete decontamination due to the high population density in our country. In the last past we present two original methods for treating liquid effluents. 1 - The use of ion-exchange resins for liquids containing relatively many salts. The

  9. Ecological assessments of effluent impacts on communities of indigenous aquatic organisms (symposium), 1979

    International Nuclear Information System (INIS)

    Bates, J.M.; Weber, C.I.

    1981-01-01

    This conference proceedings contains 17 papers, of which 4 are indexed separately. All papers deal with the effects of chemical, radioactive, and thermal effluents on aquatic organisms. The emphasis is on the methods of evaluating the effects of effluents on the standing crop, community structure, and community function

  10. Tritium effluent removal system

    International Nuclear Information System (INIS)

    Lamberger, P.H.; Gibbs, G.E.

    1978-01-01

    An air detritiation system has been developed and is in routine use for removing tritium and tritiated compounds from glovebox effluent streams before they are released to the atmosphere. The system is also used, in combination with temporary enclosures, to contain and decontaminate airborne releases resulting from the opening of tritium containment systems during maintenance and repair operations. This detritiation system, which services all the tritium handling areas at Mound Facility, has played an important role in reducing effluents and maintaining them at 2 percent of the level of 8 y ago. The system has a capacity of 1.7 m 3 /min and has operated around the clock for several years. A refrigerated in-line filtration system removes water, mercury, or pump oil and other organics from gaseous waste streams. The filtered waste stream is then heated and passed through two different types of oxidizing beds; the resulting tritiated water is collected on molecular sieve dryer beds. Liquids obtained from regenerating the dryers and from the refrigerated filtration system are collected and transferred to a waste solidification and packaging station. Component redundancy and by-pass capabilities ensure uninterrupted system operation during maintenance. When processing capacity is exceeded, an evacuated storage tank of 45 m 3 is automatically opened to the inlet side of the system. The gaseous effluent from the system is monitored for tritium content and recycled or released directly to the stack. The average release is less than 1 Ci/day. The tritium effluent can be reduced by isotopically swamping the tritium; this is accomplished by adding hydrogen prior to the oxidizer beds, or by adding water to the stream between the two final dryer beds

  11. Zero effluent; Efluente zero

    Energy Technology Data Exchange (ETDEWEB)

    Monteiro, Silvio Rogerio; Santos, Angelo Francisco dos [Liquigas Distribuidora S.A., Sao Paulo, SP (Brazil)

    2008-07-01

    A scenery of water shortage and the search for profitability improvement obligate the companies to exercise their creativity and to adopt alternative methods to the conventional ones to preserve the environmental resources. The 'Effluent Zero' project comes from a paradigms changing that the environmental preservation is a necessary cost. It brings a new analysis approach of this problem with the purpose to adapt the investments and operational costs with the effluents treatment to the demands of the productive processes. In Liquigas, the project brought significant results; made a potential reduction of nearly 90% in the investments of the effluents treatment systems. That means nearly 13% in reduction in the total investments in modernization and upgrade of the existents companies installations and of 1,6% in the total operational costs of the Company. Further more, it has contributed for a reduction of until 43% of the water consumption in the bottling process of the Liquefied Petroleum Gas (LPG). This way, the project resulted in effective actions of environmental protection with relevant economic benefits. (author)

  12. Fish diversity in adjacent ambient, thermal, and post-thermal freshwater streams

    International Nuclear Information System (INIS)

    McFarlane, R.W.

    1976-01-01

    The Savannah River Plant area is drained by five streams of various sizes and thermal histories. One has never been thermally stressed, two presently receive thermal effluent, and two formerly received thermal effluent from nuclear production reactors. Sixty-four species of fishes are known to inhabit these streams; 55 species is the highest number obtained from any one stream. Thermal effluent in small streams excludes fish during periods of high temperatures, but the streams are rapidly reinvaded when temperatures subside below lethal limits. Some cyprinids become extinct in nonthermal tributaries upstream from the thermal effluents after extended periods of thermal stress. This extinction is similar to that which follows stream impoundment. Post-thermal streams rapidly recover their fish diversity and abundance. The alteration of the streambed and removal of overhead canopy may change the stream characteristics and modify the post-thermal fish fauna

  13. Analysis of dispersion of heated effluent from power plant: a case ...

    Indian Academy of Sciences (India)

    Vikram Shah

    It is established that the thermal dispersion is influenced by wind ... effluent discharge and the excess temperature above the ambient at the ... used Generalized Environmental Modelling System for .... Cloudy day. 28/10/ ...... Earth Planet. Sci.

  14. Silver precipitation from electrolytic effluents

    International Nuclear Information System (INIS)

    Rivera, I.; Patino, F.; Cruells, M.; Roca, A.; Vinals, J.

    2004-01-01

    The recovery of silver contained in electrolytic effluents is attractive due to its high economic value. These effluents are considered toxic wastes and it is not possible to dump them directly without any detoxification process. One of the most important way for silver recovery is the precipitation with sodium ditionite, sodium borohidride or hydrazine monohidrate. In this work, the most significant aspects related to the use of these reagents is presented. Results of silver precipitation with sodium ditionite from effluents containing thiosulfate without previous elimination of other species are also presented. silver concentration in the final effluents w <1 ppm. (Author) 15 refs

  15. Treating radioactive effluent

    International Nuclear Information System (INIS)

    Kirkham, I.A.

    1981-01-01

    In the treatment of radioactive effluent it is known to produce a floc being a suspension of precipitates carrying radioactive species in a mother liquor containing dissolved non-radioactive salts. It is also known and accepted practice to encapsulate the floc in a solid matrix by treatment with bitumen, cement and the like. In the present invention the floc is washed with water prior to encapsulation in the solid matrix whereby to displace the mother liquor containing the dissolved non-radioactive salts. This serves to reduce the final amount of solidified radioactive waste with consequent advantages in the storage and disposal thereof. (author)

  16. Decentralised wastewater treatment effluent fertigation: preliminary ...

    African Journals Online (AJOL)

    Decentralised wastewater treatment effluent fertigation: preliminary technical assessment. ... living in informal settlements with the effluent produced being used on agricultural land. ... Banana and taro required 3 514 mm of irrigation effluent.

  17. Filtration device for active effluents

    International Nuclear Information System (INIS)

    Guerin, M.; Meunier, G.

    1994-01-01

    Among the various techniques relating to solid/liquid separations, filtration is currently utilized for treating radioactive effluents. After testing different equipments on various simulated effluents, the Valduc Center has decided to substitute a monoplate filter for a rotative diatomite precoated filter

  18. Elemental gradients in macrophytes from a reactor effluent gradient

    International Nuclear Information System (INIS)

    Grace, J.B.; Tilly, L.J.

    1978-01-01

    The tissues of submersed macrophtes from along the thermal gradient were analyzed for phosphorus to determine whether any pattern correspondent to standing crop distributions could be detected. Although water concentrations of phosphorus showed no detectable relationship to the thermal effluent, tissue concentrations of this element in submersed macrophytes declined with distance from the effluent entry point. The occurrence of this concentration pattern suggests that phosphorus availability is greater near the discharge. Because phosphorus is the element most often determined to limit aquatic productivity, its greater availability may partially account for the apparent enhancement of macrophte growth near the thermal discharge. A patter of macrophyte abundance which indicated enchancement related to the discharge gradient in the reactor-cooling reservoir, Par Pond is reported. Correlative data tended to implicate light and temperature as important in influencing the differential abundance pattern

  19. Disposal of tritiated effluents

    International Nuclear Information System (INIS)

    Hartmann, K.; Bruecher, H.

    1981-06-01

    After some introductory remarks on the origin of tritium, its properties and its behaviour in a reprocessing plant three alternative methods for the disposal of tritiated effluents produced during reprocessing are described (deep well injection, in-situ solidification, deep-sea dumping) and compared with each other under various aspects. The study is based on the concept of a 1400 t/a reprocessing plant for LWR fuel, which annually produces 3000 m 3 of tritiated waste water with a tritium content of 6.5 x 10 12 Bq/m 3 as well as a residual fission product and actinide content. An assessment of the three methods under the aspects of simplicity, reliability, safety, costs, state of development and materials handling revealed advantages in favour of 'injection', followed by 'dumping' and 'in-situ solidification'. (orig./HP) [de

  20. Rework of process effluents from the fabrication of HTR fuel

    Energy Technology Data Exchange (ETDEWEB)

    Lasberg, Ingo; Braehler, Georg [NUKEM Technologies GmbH (Germany); Boyes, David [Pebble Bed Modular Reactor (Pty) Ltd., Centurion (South Africa)

    2008-07-01

    HTR fuel facilities require the application of several liquid chemicals and accordingly they produce significant amounts of Uranium contaminated/potentially contaminated effluents. The main effluents are (amounts for a 3 t Uranium/a plant): aqueous solutions including tetrahydrofurfuryl alcohol THFA, ammonium hydroxide NH4OH, and ammonium nitrate NH4NO3 (180 m{sup 3}/a), isopropanol IPA/water mixtures (130 m{sup 3}/a); Non-Process Water NPW (300 m{sup 3}/a); methanol (7m{sup 3}/a); additionally off-gas streams, containing ammonia (9 t/a) have to be treated. In an industrial scale facility all such effluents/gases need to be processed for recycling, decontamination prior to release to the environment (as waste or as valuable material). Thermal decomposition is applied to dispose of burnable residues.

  1. Rework of process effluents from the fabrication of HTR fuel

    International Nuclear Information System (INIS)

    Lasberg, Ingo; Braehler, Georg; Boyes, David

    2008-01-01

    HTR fuel facilities require the application of several liquid chemicals and accordingly they produce significant amounts of Uranium contaminated/potentially contaminated effluents. The main effluents are (amounts for a 3 t Uranium/a plant): aqueous solutions including tetrahydrofurfuryl alcohol THFA, ammonium hydroxide NH4OH, and ammonium nitrate NH4NO3 (180 m 3 /a), isopropanol IPA/water mixtures (130 m 3 /a); Non-Process Water NPW (300 m 3 /a); methanol (7m 3 /a); additionally off-gas streams, containing ammonia (9 t/a) have to be treated. In an industrial scale facility all such effluents/gases need to be processed for recycling, decontamination prior to release to the environment (as waste or as valuable material). Thermal decomposition is applied to dispose of burnable residues.

  2. Facility effluent monitoring plan for WESF

    Energy Technology Data Exchange (ETDEWEB)

    SIMMONS, F.M.

    1999-09-01

    The FEMP for the Waste Encapsulation and Storage Facility (WESF) provides sufficient information on the WESF effluent characteristics and the effluent monitoring systems so that a compliance assessment against applicable requirements may be performed. Radioactive and hazardous material source terms are related to specific effluent streams that are in turn, related to discharge points and, finally are compared to the effluent monitoring system capability.

  3. Liquid Effluent Retention Facility/Effluent Treatment Facility Hazards Assessment

    International Nuclear Information System (INIS)

    Simiele, G.A.

    1994-01-01

    This document establishes the technical basis in support of Emergency Planning activities for the Liquid Effluent Retention Facility and Effluent Treatment Facility the Hanford Site. The document represents an acceptable interpretation of the implementing guidance document for DOE ORDER 5500.3A. Through this document, the technical basis for the development of facility specific Emergency Action Levels and the Emergency Planning Zone is demonstrated

  4. Hydric effluents; Os efluentes hidricos

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-07-01

    This chapter gives a general overview on the general effects of the hydric pollution, the principal pollutants emitted by the oil refineries, control actions for the hydric emissions, the minimization actions, and the effluent treatment.

  5. Waste Treatment Plant Liquid Effluent Treatability Evaluation

    International Nuclear Information System (INIS)

    LUECK, K.J.

    2001-01-01

    Bechtel National, Inc. (BNI) provided a forecast of the radioactive, dangerous liquid effluents expected to be generated by the Waste Treatment Plant (WTP). The forecast represents the liquid effluents generated from the processing of 25 distinct batches of tank waste through the WTP. The WTP liquid effluents will be stored, treated, and disposed of in the Liquid Effluent Retention Facility (LERF) and the Effluent Treatment Facility (ETF). Fluor Hanford, Inc. (FH) evaluated the treatability of the WTP liquid effluents in the LERFIETF. The evaluation was conducted by comparing the forecast to the LERFIETF treatability envelope, which provides information on the items that determine if a liquid effluent is acceptable for receipt and treatment at the LERFIETF. The WTP liquid effluent forecast is outside the current LERFlETF treatability envelope. There are several concerns that must be addressed before the WTP liquid effluents can be accepted at the LERFIETF

  6. Thermal Runaway Severity Reduction Assessment and Implementation: On Li-Ion Batteries

    Science.gov (United States)

    Darcy, Eric

    2015-01-01

    Preventing cell-cell thermal runaway propagation and flames/sparks from exiting battery enclosure is possible with proper thermal & electrical design and cell thermal runaway ejecta/effluent management and can be had with minimal mass/volume penalty.

  7. Inorganic ion exchangers. Application to liquid effluent processing

    International Nuclear Information System (INIS)

    Dozol, M.

    1983-10-01

    Main inorganic ion exchangers used for radioactive liquid effluents presented in this report are: synthetic and natural zeolites, in titanium oxides, titanates, niobates, tantalates, zirconates, some insoluble salts of zirconium, molybdenum and tin, heteropolyacids and polyantimonic acid. Properties of these ion exchangers are described: structure, adsoption, radiation effects and thermal stability, application to waste processing, radioactive waste storage uranium and cesium 137 recovery are evoked [fr

  8. 40 CFR 427.43 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS ASBESTOS MANUFACTURING POINT SOURCE CATEGORY Asbestos Paper (Elastomeric Binder) Subcategory § 427.43 Effluent limitations guidelines representing the degree of effluent...

  9. 40 CFR 427.33 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS ASBESTOS MANUFACTURING POINT SOURCE CATEGORY Asbestos Paper (Starch Binder) Subcategory § 427.33 Effluent limitations guidelines representing the degree of effluent...

  10. 40 CFR 426.113 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS GLASS MANUFACTURING POINT SOURCE CATEGORY Television Picture... applicable to the abrasive polishing and acid polishing waste water streams. Effluent characteristic Effluent...

  11. 40 CFR 426.112 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS GLASS MANUFACTURING POINT SOURCE CATEGORY Television... stream): Effluent characteristic Effluent limitations Maximum for any 1 day Average of daily values for...

  12. TBP production plant effluent treatment process

    International Nuclear Information System (INIS)

    Sriniwas, C.; Sugilal, G.; Wattal, P.K.

    2004-06-01

    TBP production facility at Heavy Water Plant, Talcher generates about 2000 litres of effluent per 200 kg batch. The effluent is basically an aqueous solution containing dissolved and dispersed organics such as dibutyl phosphate, butanol etc. The effluent has high salinity, chemical oxygen demand (30-80 g/L) and pungent odour. It requires treatment before discharge. A chemical precipitation process using ferric chloride was developed for quantitative separation of organics from the aqueous part of the effluent. This process facilitates the discharge of the aqueous effluent. Results of the laboratory and bench scale experiments on actual effluent samples are presented in this report. (author)

  13. Methanization of industrial liquid effluents; Methanisation des effluents industriels liquides

    Energy Technology Data Exchange (ETDEWEB)

    Frederic, S.; Lugardon, A. [Societe Naskeo Environnement, 92 - Levallois-Perret (France)

    2007-09-15

    In a first part, this work deals with the theoretical aspects of the methanization of the industrial effluents; the associated reactional processes are detailed. The second part presents the technological criteria for choosing the methanization process in terms of the characteristics of the effluent to be treated. Some of the methanization processes are presented with their respective advantages and disadvantages. At last, is described the implementation of an industrial methanization unit. The size and the main choices are detailed: the anaerobic reactor, the control, the valorization aspects of the biogas produced. Some examples of industrial developments illustrate the different used options. (O.M.)

  14. Methanization of industrial liquid effluents

    International Nuclear Information System (INIS)

    Frederic, S.; Lugardon, A.

    2007-01-01

    In a first part, this work deals with the theoretical aspects of the methanization of the industrial effluents; the associated reactional processes are detailed. The second part presents the technological criteria for choosing the methanization process in terms of the characteristics of the effluent to be treated. Some of the methanization processes are presented with their respective advantages and disadvantages. At last, is described the implementation of an industrial methanization unit. The size and the main choices are detailed: the anaerobic reactor, the control, the valorization aspects of the biogas produced. Some examples of industrial developments illustrate the different used options. (O.M.)

  15. Source terms for airborne effluents

    International Nuclear Information System (INIS)

    Blomeke, J.O.; Perona, J.J.

    1976-01-01

    The origin and nature of fuel cycle wastes are discussed with regard to high-level wastes, cladding, noble gases, iodine, tritium, 14 C, low-level and intermediate-level transuranic wastes, non-transuranic wastes, and ore tailings. The current practice for gaseous effluent treatment is described for light water reactors and high-temperature gas-cooled reactors. Other topics discussed are projections of nuclear power generation; projected accumulation of gaseous wastes; the impact of nuclear fuel cycle centers; and global buildup of airborne effluents

  16. Characterisation of potential aquaculture pond effluents, and ...

    African Journals Online (AJOL)

    Conventional treatment of effluents from these small-scale, low-volume operations, which discharge relatively dilute effluents infrequently, might not be cost-effective. Keywords: aquaculture–environment interaction, earthen ponds, effluent characterisation, K-means clustering, t ilapia, water quality. African Journal of Aquatic ...

  17. Facility effluent monitoring plan for WESF

    International Nuclear Information System (INIS)

    SIMMONS, F.M.

    1999-01-01

    The FEMP for the Waste Encapsulation and Storage Facility (WESF) provides sufficient information on the WESF effluent characteristics and the efferent monitoring systems so that a compliance assessment against applicable requirements may be performed. Radioactive and hazardous material source terms are related to specific effluent streams that are in turn, related to discharge points and, finally are compared to the effluent monitoring system capability

  18. Effluent from Wastewater Treatment Plants

    DEFF Research Database (Denmark)

    Kristensen, Jannie Munk; Nierychlo, Marta; Albertsen, Mads

    Incoming microorganisms to wastewater treatment plants (WWTPs) are usually considered to be removed in the treatment process. Analyses of the effluent generally show a very high degree of reduction of pathogens supporting this assumption. However, standard techniques for detecting bacteria......-independent 16SrRNA gene amplicon sequencing was applied for the identification and quantification of the microorganisms. In total 84 effluent samples from 14 full-scale Danish wastewater treatment plants were investigated over a period of 3 months. The microbial community composition was investigated by 16S r...... contain pathogenic species. One of these was Arcobacter (Campylobacteraceae) which was found in up to 16% relative abundance. This indicates that Arcobacter, and perhaps other pathogenic genera, are not being removed efficiently in full-scale plants and may pose a potential health safety problem. Further...

  19. Continuous monitoring of gaseous effluents

    International Nuclear Information System (INIS)

    Velasco, A.; Giraut, H.; Prado, M.; Bonino, A.D.

    1990-01-01

    The system allows to continuously determine the radioactive materials discharge (iodine, noble gases and aerosols) to the environment. It consists in compelling, by a pump, a known and fixed fraction of the total flow and preserving the aerosols by a filter. The gas -now free from aerosols- traverses an activated carbon filter which keeps the iodine; after being free from aerosols and iodine, the effluent traverses a measurement chambers for noble gases which has a scintillator. (Author) [es

  20. Waste monitoring system for effluents

    International Nuclear Information System (INIS)

    Macdonald, J.M.; Gomez, B.; Trujillo, L.; Malcom, J.E.; Nekimken, H.; Pope, N.; Bibeau, R.

    1995-07-01

    The waste monitoring system in use at Los Alamos National Laboratory's Plutonium Facility, TA-55, is a computer-based system that proves real-time information on industrial effluents. Remote computers monitor discharge events and data moves from one system to another via a local area network. This report describes the history, system design, summary, instrumentation list, displays, trending screens, and layout of the waste monitoring system

  1. USERDA effluent data collection and reporting program

    International Nuclear Information System (INIS)

    Elle, D.R.; Schoen, A.A.

    1978-01-01

    Effluent and environmental monitoring has been conducted at United States Energy Research and Development Administration (formerly United States Atomic Energy Commission) facilities and sites virtually since the inception of atomic energy research and development. In 1971, computer systems were developed that permitted storage of information and data characterizing each effluent and onsite discharge point and relevant information on sources, effluent treatment and control systems, and discharge data, and serve as ERDA's computer-based management information systems for compiling waste discharge control and monitoring data on radioactivity released as airborne or liquid effluents or liquid discharges to onsite retention basins at ERDA facilities. The information systems and associated data outputs have proved to be an effective internal management tool for identifying effluent control problem areas and for surveying an agencywide Radioactive Effluent Reduction Program. The trend data facilitate the detection of gradual changes in the effectiveness of waste treatment systems, and errors or oversights in monitoring and data handling. Other computer outputs are useful for identifying effluent release points that have significantly higher or lower concentrations or quantities in the discharge stream than were measured the previous year. The year-to-year trend reports and the extensive computer edit and error checks have improved the reliability of the reported effluent data. Adoption of a uniform, centralized reporting system has improved the understanding and credibility of effluent data, and has allowed management to evaluate the effectiveness of effluent control practices at ERDA facilities. (author)

  2. Liquid Effluents Program mission analysis

    International Nuclear Information System (INIS)

    Lowe, S.S.

    1994-01-01

    Systems engineering is being used to identify work to cleanup the Hanford Site. The systems engineering process transforms an identified mission need into a set of performance parameters and a preferred system configuration. Mission analysis is the first step in the process. Mission analysis supports early decision-making by clearly defining the program objectives, and evaluating the feasibility and risks associated with achieving those objectives. The results of the mission analysis provide a consistent basis for subsequent systems engineering work. A mission analysis was performed earlier for the overall Hanford Site. This work was continued by a ''capstone'' team which developed a top-level functional analysis. Continuing in a top-down manner, systems engineering is now being applied at the program and project levels. A mission analysis was conducted for the Liquid Effluents Program. The results are described herein. This report identifies the initial conditions and acceptable final conditions, defines the programmatic and physical interfaces and sources of constraints, estimates the resources to carry out the mission, and establishes measures of success. The mission analysis reflects current program planning for the Liquid Effluents Program as described in Liquid Effluents FY 1995 Multi-Year Program Plan

  3. Observations of Crassostrea virginica cultured in the heated effluent and discharged radionuclides of a nuclear power reactor

    International Nuclear Information System (INIS)

    Price, A.H.; Hess, C.T.; Smith, C.W.

    1976-06-01

    American oysters (Crassostrea virginica) were rafted for 26 months at four sites in the effluent waters near Maine Yankee Nuclear Power Reactor in Montsweag Bay and at a control site in the adjacent Damariscotta River. In an evaluation of the thermal effluent for aquaculture, comparisons are made among the sites of the effects of heated effluent on oyster growth and condition, and the uptake and retention of gamma-ray emitting radionuclides. Growth and uptake of radionuclides were observed to be accelerated at the warmer water sites. Both experimental results and calculations for 58 Co and 54 Mn are presented

  4. Legal provisions governing liquid effluents radiological monitoring

    International Nuclear Information System (INIS)

    Gans, I.; Ruehle, H.

    1985-01-01

    The KTA rule 1504 for radiological monitoring of liquid effluents from nuclear installations is explained. As there are no such rules published to date for establishments handling isotopes, some criteria are discussed which in the future ought to form part of a practical guide for liquid effluents monitoring in isotope handling installations. Monitoring measures described refer to liquid effluents from transfer containers, auxiliary cooling equipment, turbine buildings, main cooling installations, and waste air discharges from closed-circuit cooling systems. (DG) [de

  5. Radiation treatment of sewage effluent, (2)

    International Nuclear Information System (INIS)

    Sawai, Teruko; Sekiguchi, Masayuki; Sawai, Takeshi; Shimokawa, Toshinari; Tanabe, Hiroko

    1991-01-01

    The water demand of the past several years has increased rapidly. Recycling of municipal waste water is an effective mean of coping with the water shortage in Tokyo. We studied the radiation treatment method of further purification of the effluent from sewage treatment plants. By gamma irradiation the refractory organic substances in the effluent were decomposed and the COD values decreased with increasing dose. The high molecular weight components in the effluent were degraded to lower molecular weight substances and were decomposed finally to carbon dioxide. In this paper we studied on the fading color and the reducing of order of sewage effluent. (author)

  6. CY-1981 effluent monitoring report

    International Nuclear Information System (INIS)

    Honkus, R.J.

    1982-05-01

    The effluent monitoring programs at ICPP for calendar year 1981 are summarized. During the year, five significant occurrences or unplanned releases occurred. These are briefly described and tabulated. In none of the instances were the applicable Radiation Concentration Guides (RCG's) exceeded. A graphic summary of the total airborne, liquid and solid releases during CY-1981 is presented. Liquid waste activity was higher than anticipated due to various processing factors throughout the year. Solid waste jumped dramatically in December due to shipment of end-prices from the EBR-II fuel which was processed during the Electrolytic campaign

  7. Cytogenotoxicity evaluation of two industrial effluents using Allium ...

    African Journals Online (AJOL)

    ISHIOMA

    textile effluent was 4.5 times more toxic than the paint effluent. ... Key words: Genotoxicity, paint, textile, industrial effluents, Allium cepa, mutation, pollution, chromosomal .... concentration of a chemical producing 50% of the total effect).

  8. 40 CFR 417.162 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY Manufacture of Liquid Detergents Subcategory § 417.162 Effluent limitations guidelines... available (BPT): (a) For normal liquid detergent operations the following values pertain: Effluent...

  9. Effluent management and pollution control

    International Nuclear Information System (INIS)

    Ananda Narayanan, R.; Vedamoorthy, S.

    2006-01-01

    Generation of waste/effluent has a direct impact on environment, the higher the generation of waste higher the environmental impact. Though complete prevention of radioactive waste generation is a difficult task, keeping the waste generation to the minimum practicable is essential objective of Radioactive Waste Management. In doing so, it is essential to minimize waste generation at all the stages of a Nuclear Plant Cycle. Waste minimization refers to both a) Waste generation by operational and maintenance activities of plant and b) Secondary waste resulting from predisposal management of Radioactive Waste. The management of the effluent can be done in efficient manner by better designs, improved procedure, periodic reviews and above all inculcate the awareness amongst the waste generators since minimisation of waste, at source is the most efficient way to safe guard the environment. Commissioning and rich operating experience of waste management plant gather novel ideas which result in beneficial improvements in the system and operating procedure. Some of the steps initiated by designers and site agencies towards this are worth mentioning. (author)

  10. Dispersion of effluents in the atmosphere; Dispersion des effluents dans l`atmosphere

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-12-31

    This conference day was organized by the `convection` section of the French association of thermal engineers with the support of the environment and energy mastery agency (ADEME). This book of proceedings contains 10 papers entitled: `physical modeling of atmospheric dispersion in wind tunnels. Some industrial examples`; `modeling of the noxious effects of a fire on the environment of an industrial site: importance of thermal engineering related hypotheses`; `atmospheric diffusion of a noxious cloud: fast evaluation method of safety areas around refrigerating installations that use ammonia`; `modeling of atmospheric flows in urban areas in order to study the dispersion of pollutants`; `use of a dispersion parameter to characterize the evolution of a diffusion process downstream of a linear source of passive contaminant placed inside a turbulent boundary layer`; `elements of reflexion around the development of an analytical methodology applied to the elaboration of measurement strategies of air quality in ambient and outdoor atmospheres around industrial sites`; `state-of-the-art about treatment techniques for VOC-rich gaseous effluents`; `characteristics of the time variation of the atmospheric pollution in the Paris region and visualization of its space distribution`; `mass-spectrometry for the measurement of atmospheric pollutants`; `volume variations in natural convection turbulence`. (J.S.)

  11. Dispersion of effluents in the atmosphere; Dispersion des effluents dans l`atmosphere

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-12-31

    This conference day was organized by the `convection` section of the French association of thermal engineers with the support of the environment and energy mastery agency (ADEME). This book of proceedings contains 10 papers entitled: `physical modeling of atmospheric dispersion in wind tunnels. Some industrial examples`; `modeling of the noxious effects of a fire on the environment of an industrial site: importance of thermal engineering related hypotheses`; `atmospheric diffusion of a noxious cloud: fast evaluation method of safety areas around refrigerating installations that use ammonia`; `modeling of atmospheric flows in urban areas in order to study the dispersion of pollutants`; `use of a dispersion parameter to characterize the evolution of a diffusion process downstream of a linear source of passive contaminant placed inside a turbulent boundary layer`; `elements of reflexion around the development of an analytical methodology applied to the elaboration of measurement strategies of air quality in ambient and outdoor atmospheres around industrial sites`; `state-of-the-art about treatment techniques for VOC-rich gaseous effluents`; `characteristics of the time variation of the atmospheric pollution in the Paris region and visualization of its space distribution`; `mass-spectrometry for the measurement of atmospheric pollutants`; `volume variations in natural convection turbulence`. (J.S.)

  12. Bioremediation of petroleum refinery effluent by Planococcus ...

    African Journals Online (AJOL)

    In the present investigation, Planococcus halophilus was screened for hydrocarbon degradation and bioremediation of refinery effluent. The test organism, P. halophilus, showed the capability to utilize kerosene as carbon source in minimal medium. Biological treatment of the refinery effluent with P. halophilus reduced the ...

  13. 324 and 327 Facilities Environmental Effluent Specifications

    International Nuclear Information System (INIS)

    JOHNSON, D.L.

    1999-01-01

    These effluent specifications address requirements for the 324/321 Facilities, which are undergoing stabilization activities. Effluent specifications are imposed to protect personnel, the environment and the public, by ensuring adequate implementation and compliance with federal and state regulatory requirements and Hanford programs

  14. Animal alternatives for whole effluent toxicity testing ...

    Science.gov (United States)

    Since the 1940s, effluent toxicity testing has been utilized to varying degrees in many countries to assess potential ecological impacts and assist in determining necessary treatment options for environmental protection. However, it was only in the early 1980’s that toxicity based effluent assessments and subsequent discharge controls became globally important, when it was recognized that physical and chemical measurements alone did not protect the environment from potential impacts. Consequently, various strategies using different toxicity tests, whole effluent assessment techniques (incorporating bioaccumulation potential and persistence) plus supporting analytical tools have been developed over 30 years of practice. Numerous workshops and meetings have focused on effluent risk assessment through ASTM, SETAC, OSPAR, UK competent authorities, and EU specific country rules. Concurrent with this drive to improve effluent quality using toxicity tests, interest in reducing animal use has risen. The Health and Environmental Sciences Institute (HESI) organized and facilitated an international workshop in March 2016 to evaluate strategies for concepts, tools, and effluent assessments and update the toolbox of for effluent testing methods. The workshop objectives were to identify opportunities to use a suite of strategies for effluents, and to identify opportunities to reduce the reliance on animal tests and to determine barriers to implementation of new methodologie

  15. EPA Enforcement and Compliance History Online: Water Effluent Charts Details

    Data.gov (United States)

    U.S. Environmental Protection Agency — Detailed Discharge Monitoring Report (DMR) data supporting effluent charts for one Clean Water Act discharge permit. Includes effluent parameters, amounts discharged...

  16. 40 CFR 407.67 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS CANNED AND PRESERVED FRUITS AND VEGETABLES PROCESSING POINT SOURCE CATEGORY Canned and Preserved Fruits Subcategory § 407.67 Effluent limitations guidelines...

  17. 40 CFR 407.77 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS CANNED AND PRESERVED FRUITS AND VEGETABLES PROCESSING POINT SOURCE CATEGORY Canned and Preserved Vegetables Subcategory § 407.77 Effluent limitations guidelines...

  18. 40 CFR 417.83 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY Manufacture of Liquid Soaps Subcategory § 417.83 Effluent limitations guidelines representing the degree of...

  19. 40 CFR 417.82 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY Manufacture of Liquid Soaps Subcategory § 417.82 Effluent limitations guidelines representing the...

  20. 40 CFR 415.342 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... SOURCE CATEGORY Chrome Pigments Production Subcategory § 415.342 Effluent limitations guidelines... available (BPT): Subpart AH—Chrome Pigments Pollutant or pollutant property BPT effluent limitations Maximum...

  1. 40 CFR 415.647 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... CATEGORY Cadmium Pigments and Salts Production Subcategory § 415.647 Effluent limitations guidelines... subject to this subpart and producing cadmium pigments must achieve the following effluent limitations...

  2. 40 CFR 415.643 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... CATEGORY Cadmium Pigments and Salts Production Subcategory § 415.643 Effluent limitations guidelines... subject to this subpart and producing cadmium pigments must achieve the following effluent limitations...

  3. 40 CFR 440.23 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Science.gov (United States)

    2010-07-01

    ...) EFFLUENT GUIDELINES AND STANDARDS ORE MINING AND DRESSING POINT SOURCE CATEGORY Aluminum Ore Subcategory... discharged in mine drainage from mines producing bauxite ores shall not exceed: Effluent characteristic...

  4. 40 CFR 440.22 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS ORE MINING AND DRESSING POINT SOURCE CATEGORY Aluminum Ore... pollutants discharged in mine drainage from mines producing bauxite ores shall not exceed: Effluent...

  5. 40 CFR 406.73 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... economically achievable. 406.73 Section 406.73 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY....73 Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

  6. Biochemical methane potential of kraft bleaching effluent and codigestion with other in-mill streams

    DEFF Research Database (Denmark)

    Fitamo, Temesgen Mathewos; Dahl, Olli; Master, Emma

    2016-01-01

    and in combination: total bleaching effluent, alkaline bleaching effluent, kraft evaporator condensate, and chemithermomechanical pulping effluent. The total bleaching effluent, consisting of the chlorine dioxide bleaching and alkaline bleaching effluents, exhibited the highest potential for organic matter...

  7. Treating effluents; recovering coal, etc

    Energy Technology Data Exchange (ETDEWEB)

    Jones, F B; Bury, E

    1920-02-18

    Liquor obtained by scrubbing coal gas with sea-water or fresh water, and containing or having added to it finely-divided carbonaceous material in suspension, is subjected to a froth-flotation process to recover the carbonaceous matter and organic materials in the froth, and render the remaining liquor innocuous. Liquor obtained by scrubbing distillation gases, such as coal gas, may be used as a frothing-agent in a froth flotation process for the recovery of carbonaceous substances such as coal from materials containing them, thereby producing a froth containing the coal, etc., and also the organic materials from the liquor. In some cases the effluent may be diluted with sea-water, and, in recovering carbonaceous shales, there may be added to the liquor a small proportion of paraffin oil.

  8. Suspended solids in liquid effluents

    International Nuclear Information System (INIS)

    McGrath, J.J.

    1988-06-01

    An international literature review and telephone mail survey was conducted with respect to technical and regulatory aspects of suspended solids in radioactive liquid wastes from nuclear power stations. Results of the survey are summarized and show that suspended solids are an important component of some waste streams. The data available, while limited, show these solids to be associated largely with corrosion products. The solids are highly variable in quantity, size and composition. Filtration is commonly applied for their removal from liquid effluents and is effective. Complex interactions with receiving waters can result in physical/chemical changes of released radionuclides and these phenomena have been seen as reason for not applying regulatory controls based on suspended solids content. 340 refs

  9. Radiological consequences of radioactive effluents

    International Nuclear Information System (INIS)

    Clarke, R.H.

    1979-01-01

    A study of the differential radiological impact of the nuclear fuel cycle with and without plutonium recycle is being undertaken jointly by the National Radiological Protection Board and the Commissariat a l'Energie Atomique (CEA). A summary is given of the development of the methodology detailed in their first report to the Commission of the European Communities (CEC) (NRPB/CEA, A methodology for evaluating the radiological consequences of radioactive effluents released in normal operations. Luxembourg, CEC Doc. V/3011/75 EN (1979)). The Collective Effective Dose Equivalent Commitment was used in an attempt to assess the total health detriment. The application of the methodology within particular member states of the European Community has been discussed at seminars. Sensitivity analysis can identify the more important parameters for improving the accuracy of the assessment. (UK)

  10. Assessment methodology for radioactive effluents

    International Nuclear Information System (INIS)

    Anon.

    1977-01-01

    The objective of this environmental assessment is to define and rank the needs for controlling radioactive effluents from nuclear fuel cycle facilities. The assessment is based on environmental standards and dose-to-man calculations. The study includes three calculations for each isotope from each facility: maximum individual dose for a 50-year dose commitment from a 1-yr exposure according to the organ affected; population dose for a 50-yr dose commitment from a 1-yr exposure according to the organ affected; and annual dose rate for the maximally exposed individual. The relative contribution of a specific nuclide and source to the total dose provides a method of ranking the nuclides, which in turn identifies the sources that should receive the greatest control in the future. These results will be used in subsequent tasks to assess the environmental impact of the total nuclear fuel cycle

  11. Studies on Lyari river effluents

    International Nuclear Information System (INIS)

    Khan, M.A.; Hashmi, I.; Rashid, A.; Niaz, G.R.; Khan, F.

    1999-01-01

    The study was aimed to determining the physical (TS, TSS, TDS, TVS) and chemical (Cl, SO/sub 4/, NH/sub 3/, BOD/sub 5/ COD, DO) characteristics as well as heavy present in the Lyari river effluents so as to identify the extent of pollution. The average results of each parameter of twelve different sites were compared with that of National Environmental Quality Standards (NEQS), BOD/sub 5/ and COD levels were above the NEQS while the NH/sub 3/-N concentration was low. Concentrations of Cd and Zn were within the range while that of Pb, Cr, Ni and Cu were higher than the NEQS at times. This indicates that heavy pollution load is entering into the Arabian Sea creating tremendous harm especially to marine life. (author)

  12. Effluent monitoring for nuclear safeguards

    International Nuclear Information System (INIS)

    Stanchi, L.

    1977-01-01

    A microprocessor-based instrument operates a continuous surveillance on effluents from a nuclear facility. It receives and evaluates pulses from two NaI detectors and a set of single-channel analyzers. It has self-diagnosing capability so that it takes actions not only when it recognizes excessive radioactivity but also when it ascertains some abnormal behavior. Power failure procedure and automatic restart are provided. Operative constants such as alarm thresholds, times, and number of successive measurements are permanently stored in a read/write battery operated C-MOS memory. The program allows automatic succession of phases in a peculiar way and has a feature for loading an auxiliary program into RAMs

  13. Arsenic precipitation from metallurgical effluents

    International Nuclear Information System (INIS)

    Navarro, P.; Vargas, C.; Araya, E.; Martin, I.; Alguacil, F. J.

    2004-01-01

    In the mining-metallurgical companies different liquid effluents are produced, which can contain a series of dissolved elements that are considered dangerous from an environmental point of view. One of these elements is the arsenic, especially in the state of oxidation +5 that can be precipitated as calcium or iron arsenate. To fulfil the environmental requests it should have in solution a content of arsenic lower than 0,5 mg/l and the obtained solid product should be very stable under the condition in which it will be stored. this work looks for the best conditions of arsenic precipitation, until achieving contents in solution lower than such mentioned concentration. Also, the stability of the precipitates was studied. (Author) 7 refs

  14. Effluent monitoring for nuclear safeguards

    International Nuclear Information System (INIS)

    Stanchi, L.

    1976-01-01

    A microprocessor-based instrument operates a continuous surveillance on effluents from a nuclear facility. It receives and evaluates pulses from two NaI detectors and a set of single-channel analyzers. It has self-diagnosing capability so that it takes actions not only when it recognizes excessive radioactivity but also when it ascertains some abnormal behavior. Power failure procedure and automatic restart are provided. Operative constants such as alarm thresholds, times, and number of successive measurements are permanently stored in a read/write battery operated C-MOS memory. The program allows automatic succession of phases in a peculiar way and has a feature for loading an auxiliary program into RAMs

  15. Liquid effluent processing group. Activity details 1963

    International Nuclear Information System (INIS)

    1964-08-01

    This report first gives a quantitative overview of volumes of effluents of high activity, medium activity and low activity which passed through the department for effluent processing. It also makes the distinction between the shape or type of container of these effluents. A table indicates their origin and another indicates their destination. The β and α decontamination rates are determined, and the assessment of stored aqueous and organic effluents on the 31 December 1963 is given. The next part proposes an assessment of laboratory activities: control operations (input controls, control of processed effluent before discarding), controls related to processing (processing types, radiochemical and chemical dosing performed on effluent mixes before processing). Tables indicate the characteristics of medium activity effluents collected in 1963, the results of high activity liquid analysis, and Beryllium dosing results. A summary of ALEA processing, a table of the characteristics of stored oils and solvents are given. The third part reports data related to transport activities, and various works performed in the Saclay plant to improve exploitation conditions and results

  16. Angra-1 NPP thermal influence on liquid effluent discharge zone

    International Nuclear Information System (INIS)

    Costa, Daniel de Araujo

    1996-01-01

    The Angra I Nuclear Power Plant makes use of sea-water to condense the steam generated in its secondary circuit. This water, collected from Itaorna bay, is then chlorinated and discharged, with higher temperature, in the Piraquara de Fora bay. Aiming the study of the marine ecosystem, submitted to the effects of the Nuclear Power Plant discharge water, the temperature, residual chlorine, flora and fauna are periodically monitored. Being sensitive to temperature variations and to chemical products, macroscopic algae are also bio-accumulators and primary producers, because of this, they are considered the main link in the food chain and therefore important bio-indicator. This paper shows the variation of species from the brown algae near the discharge of Angra I Nuclear Power Plant. (author)

  17. Supercritical water oxidation test bed effluent treatment study

    International Nuclear Information System (INIS)

    Barnes, C.M.

    1994-04-01

    This report presents effluent treatment options for a 50 h Supercritical Water Test Unit. Effluent compositions are calculated for eight simulated waste streams, using different assumed cases. Variations in effluent composition with different reactor designs and operating schemes are discussed. Requirements for final effluent compositions are briefly reviewed. A comparison is made of two general schemes. The first is one in which the effluent is cooled and effluent treatment is primarily done in the liquid phase. In the second scheme, most treatment is performed with the effluent in the gas phase. Several unit operations are also discussed, including neutralization, mercury removal, and evaporation

  18. Primary effluent filtration for coastal discharges

    Energy Technology Data Exchange (ETDEWEB)

    Cooper-Smith, G.D. [Yorkshire Water Services, Huddersfield (United Kingdom); Rundle, H. [The Capital Controls Group, Nottingham (United Kingdom)

    1998-12-31

    The use of a Tetra Deep Bed filter demonstration unit to treat primary effluent (Primary Effluent Filtration, PEF) was investigated. PEF proved capable of achieving the UWWTD primary standard, even when the primary stage performs poorly, but is not a cost-effective alternative to chemically assisted settlement. Results demonstrated that using a 1.5 to 2.2 mm grade medium, a filtration rate of 5 m/h, three backwashes a day and dosing 40 mg/l of PAXXL60 (a polyaluminium silicte) an average effluent quality of 20 mg/l BOD and 15 mgl/l total solid could be achieved. UV disinfection produced an effluent which complied with the Bathing Water Directive imperative requirement. A high enterovirus kill was also achieved. However, considerable additional work would be required before PEF could be considered suitable for full-scale applications. (orig.)

  19. A WET TALE: TOXICITY OF COMPLEX EFFLUENTS

    Science.gov (United States)

    This course covers standards, regulations, policy, guidance and technical aspects of implementing the whole effluent toxicity program. The curriculum incorporates rationale and information on WET test requirements from USEPA documents, such as the Technical Support Document for W...

  20. Effluent monitoring: Its purpose and value

    International Nuclear Information System (INIS)

    Schoen, A.A.

    1978-01-01

    The purpose of effluent monitoring is described in terms of the primary objectives, the most important of which is to verify that the facility is functioning as it was designed and that the waste treatment and effluent control systems are performing as planned and expected. The object of a monitoring programme should be periodically re-examined to ensure that the programme serves a contemporary purpose. The value of the effluent monitoring programme is determined by the extent to which users of the monitoring data, i.e. the operator, the regulating authorities and the public, accept the result as indicating that the plant is operating safely, and in an environmentally acceptable manner. The credibility of the monitoring results is therefore the most important factor determining the value of an effluent monitoring programme. (author)

  1. THE EFFECT OF REFINERY AND PETROCHEMICAL EFFLUENT ...

    African Journals Online (AJOL)

    Dr Osondu

    Ethiopian Journal of Environmental Studies and Management Vol. 4 No.2 ... Abstract. This study investigated the effects of treated effluent discharge on the water quality of Ubeji Creek, Warri. ..... Sodium increase is as a result of oil leakage.

  2. Bioremediation of textile effluent using Phanerochaete chrysosporium

    African Journals Online (AJOL)

    Bioremediation of textile effluent using Phanerochaete chrysosporium. ... African Journal of Biotechnology. Journal Home · ABOUT THIS ... The discharge of these waste residues into the environment eventually poison, damage or affect one or ...

  3. Effluent Treatment Facility tritium emissions monitoring

    International Nuclear Information System (INIS)

    Dunn, D.L.

    1991-01-01

    An Environmental Protection Agency (EPA) approved sampling and analysis protocol was developed and executed to verify atmospheric emissions compliance for the new Savannah River Site (SRS) F/H area Effluent Treatment Facility. Sampling equipment was fabricated, installed, and tested at stack monitoring points for filtrable particulate radionuclides, radioactive iodine, and tritium. The only detectable anthropogenic radionuclides released from Effluent Treatment Facility stacks during monitoring were iodine-129 and tritium oxide. This paper only examines the collection and analysis of tritium oxide

  4. Studies on the recovery of lithium from wash effluent generated during preparation of Li2TiO3 (Lithium Titanate) microspheres for ITER

    International Nuclear Information System (INIS)

    Bamankar, Y.R.; Vittal Rao, T.V.; Pius, I.C.; Mukerjee, S.K.

    2013-01-01

    Methods are being developed for the recovery of lithium from wash effluent generated during the preparation of lithium titanate microspheres which are to be used for breeding tritium in ITER Program. Thermal decomposition of the wash effluent in a furnace at 600°C, resulted in decomposition of the impurities such as ammonium chloride, ammonium nitrate, HMTA, and Urea etc., yielding pure lithium salt. Thermal decomposition of wash effluent containing nitrate was carried out in a controlled manner to avoid explosive decomposition of HMTA and ammonium nitrate. Preliminary investigations were also carried out for the separation of lithium as lithium hydroxide from wash effluent using ion exchange membrane coupled with an electrolytic cell. (author)

  5. Assessment of effluent turbidity in mesophilic and thermophilic sludge reactors - origin of effluent colloidal material

    NARCIS (Netherlands)

    Vogelaar, J.C.T.; Lier, van J.B.; Klapwijk, B.; Vries, M.C.; Lettinga, G.

    2002-01-01

    Two lab-scale plug flow activated sludge reactors were run in parallel for 4 months at 30 and 55°C. Research focussed on: (1) COD (chemical oxygen demand) removal, (2) effluent turbidity at both temperatures, (3) the origin of effluent colloidal material and (4) the possible role of protozoa on

  6. Flow proportional sampling of low level liquid effluent

    International Nuclear Information System (INIS)

    Colley, D.; Jenkins, R.

    1989-01-01

    A flow proportional sampler for use on low level radioactive liquid effluent has been developed for installation on all CEGB nuclear power stations. The sampler, operates by drawing effluent continuously from the main effluent pipeline, through a sampler loop and returning it to the pipeline. The effluent in this loop is sampled by taking small, frequent aliquots using a linear acting shuttle valve. The frequency of operation of this valve is controlled by a flowmeter installed in the effluent line; sampling rate being directly proportional to effluent flowrate. (author)

  7. 200 Area Liquid Effluent Facilities -- Quality assurance program plan

    International Nuclear Information System (INIS)

    Fernandez, L.

    1995-01-01

    This Quality Assurance Program Plan (QAPP) describes the quality assurance and management controls used by the 200 Area Liquid Effluent Facilities (LEF) to perform its activities in accordance with DOE Order 5700.6C. The 200 Area LEF consists of the following facilities: Effluent Treatment Facility (ETF); Treated Effluent Disposal Facility (TEDF); Liquid Effluent Retention facility (LERF); and Truck Loading Facility -- (Project W291). The intent is to ensure that all activities such as collection of effluents, treatment, concentration of secondary wastes, verification, sampling and disposal of treated effluents and solids related with the LEF operations, conform to established requirements

  8. Utilization of portable effluent wastewater in brick manufacturing

    International Nuclear Information System (INIS)

    EI-Mahllawy, M.S.; El-Sokkary, T.M.

    2005-01-01

    Portable wastewater is produced from sedimentation and filtration tanks in portable water treatment plants. Usually, this useless wastewater is drained into River Nile Canal and not to the sewer system causing a potential pollution. Wastewater has been taken from Portable Treatment Plant located at Qalubia Province, Delta, Egypt. Evaluation of raw materials was carried out by using X-ray diffraction (XRD), X-ray fluorescence (XRF), thermal analyses (DTA and TGA) as well as plasticity and drying sensitivity coefficient (DSC) measurements. Technological properties of fired bricks were investigated according to Egyptian and American Specifications. The obtained experimental results encourage substitution of the drained portable wastewater for the tap water in bricks manufacturing. Thus, utilization of the studied portable effluent wastewater in such industry is possible and fulfills the double target of saving drinking water used in clay bricks manufacturing, rather than its environmental pollution prevention. Keywords: Portable wastewater, tap water, clay building bricks, physicomechanical properties

  9. 200 Area Effluent Treatment Facility: Delisting petition

    International Nuclear Information System (INIS)

    1993-08-01

    Waste water has been generated for over 40 years as a result of operations conducted on the Hanford Site. This waste water previously was discharged to cribs, ponds, or ditches. An example of such waste water includes process condensate that might have been in contact with dangerous waste or mixed waste (containing both radioactive and dangerous components). This petition presents the treatment technologies that are designed into the 200 Area Effluent Treatment Facility to eliminate the dangerous characteristics of the waste and to delist the effluent in accordance with the requirements found in 40 Code of Federal Regulations 260.20 and 260.22. The purpose of this petition is to demonstrate that the 242-A Evaporator process condensate will be treated adequately so that the effluent from the 200 Area Effluent Treatment Facility will no longer require management as a regulated dangerous waste. This demonstration was performed by use of a surrogate (synthetic) waste, designed by the US Department of Energy, Richland Operations Office to include species that represent all organic and inorganic constituents (but not radionuclide species) expected to be found on the Hanford Site. Thus, the surrogate will encompass not only the expected 242-A Evaporator process condensate characteristics, but those of other potential 200 Area Effluent Treatment Facility waste streams and additional 40 CFR Appendix VIII constituents

  10. Treatment of effluents in uranium industry

    International Nuclear Information System (INIS)

    Ghosh, S.K.

    2009-01-01

    Uranium processing technology in India has matured in the last 50 years and is able to meet the country's requirement. Right from mining of the ore to milling and refining, effluents are generated and are being processed for their safe disposal. While the available technology is able to meet the regulatory limits of the effluents, the same may not be enough to meet the increased demand of uranium in the future. The increased population, urbanization and climate change are not only going to decrease the supply of process water but will also place increased restrictions on disposal to environment. This demands technologies that will generate less effluent for disposal and enable reuse and recycle concept to the extent possible. Presently used conventional physical-chemical methods, to contain the contaminants would, therefore, require further refinements. Contaminants like sulfates, chlorides etc in the effluent of uranium mill based on acid leach process are the concerns for the future plants. Hence, there is an urgent need for development of suitable methods for maximum recycle of the process effluents, which will also enable in minimizing the consumption of process water. A suitable membrane based process can be an option leaving a concentrated brine for reuse or for further treatment and disposal

  11. High-yield pulping effluent treatment technologies

    International Nuclear Information System (INIS)

    Su, W.X.; Hsieh, J.S.

    1993-03-01

    The objective of this report is to examine the high-yield (mechanical) pulp processes with respect to environmental issues affected by the discharge of their waste streams. Various statistics are given that support the view that high-yield pulping processes will have major growth in the US regions where pulp mills are located, and sites for projects in the development phase are indicated. Conventional and innovative effluent-treatment technologies applicable to these processes are reviewed. The different types of mechanical pulping or high-yield processes are explained, and the chemical additives are discussed. The important relationship between pulp yield and measure of BOD in the effluent is graphically presented. Effluent contaminants are identified, along with other important characteristics of the streams. Current and proposed environmental limitations specifically related to mechanical pulp production are reviewed. Conventional and innovative effluent-treatment technologies are discussed, along with their principle applications, uses, advantages, and disadvantages. Sludge management and disposal techniques become an intimate part of the treatment of waste streams. The conclusion is made that conventional technologies can successfully treat effluent streams under current waste-water discharge limitations, but these systems may not be adequate when stricter standards are imposed. At present, the most important issue in the treatment of pulp-mill waste is the management and disposal of the resultant sludge

  12. Cyanobacterial flora from polluted industrial effluents.

    Science.gov (United States)

    Parikh, Amit; Shah, Vishal; Madamwar, Datta

    2006-05-01

    Effluents originating from pesticides, agro-chemicals, textile dyes and dyestuffs industries are always associated with high turbidity, colour, nutrient load, and heavy metals, toxic and persistent compounds. But even with such an anthropogenic nature, these effluents contain dynamic cyanobacterial communities. Documentation of cyanobacterial cultures along the water channels of effluents discharged by above mentioned industries along the west coast of India and their relationship with water quality is reported in this study. Intensity of pollution was evaluated by physico-chemical analysis of water. Higher load of solids, carbon and nutrients were found to be persistent throughout the analysis. Sediment and water samples were found to be colored in nature. Cyanobacterial community structure was found to be influenced by the anthropogenic pollution. 40 different cyanobacterial species were recorded from 14 genera of 5 families and an elevated occurrence of Phormidium, Oscillatoria and Chroococcus genera was observed in all the sampling sites.

  13. Effluent treatment plant and decontamination centre, Trombay

    International Nuclear Information System (INIS)

    Kaushik, C.P.; Agarwal, K.

    2017-01-01

    The Bhabha Atomic Research Centre, Trombay, has a number of plants and laboratories, which generate Radioactive Liquid Waste and Protective Wears. Two facilities have been established in late 1960s to cater to this requirement. The Centre, on the average generates about 50,000 m"3 of active liquid effluents of varying specific activities. The Effluent Treatment Plant was setup to receive and process radioactive liquids generated by various facilities of BARC in Trombay. It also serves a single-point discharge facility to enable monitoring of radioactive effluents discharged from the Trombay site. About 120-150 Te of protective wears and inactive apparel are generated annually from various radioactive facilities and laboratories of BARC. In addition, contaminated fuel assembly components are generated by DHRUVA and formerly by CIRUS. These components require decontamination before its recycle to the fuel assembly process. The Decontamination Centre, setup in late 1960s, is mandated to carry out the above mentioned decontamination activities

  14. Recycling liquid effluents in a ceramic industry

    International Nuclear Information System (INIS)

    Araujo Almeida, B.; Almeida, M.; Martins, S.; Alexandra Macarico, V.; Tomas da Fonseca, A.

    2016-01-01

    In this work is presented a study on the recycling of liquid effluents in a ceramic installation for sanitary industry. The effluents were characterized by X-ray diffraction and inductively coupled plasma to evaluate their compositions. It was also assessed the daily production rate. Several glaze-slurry mixtures were prepared and characterized according to procedures and equipment of the company's quality laboratory. The results show that for most of the properties, the tested mixtures exhibited acceptable performance. However, the pyro plasticity parameter is highly influenced by the glaze content and imposes the separation of glaze and slurry liquid effluents. In addition, it is necessary to invest on a storage plant, including tanks with constant stirring and a new pipeline structure to implement the reincorporation method on the slurry processing. (Author)

  15. Performance and emissions of an engine fuelled by biogas of palm oil mill effluent

    Science.gov (United States)

    Arjuna, J.; Sitorus, T. B.; Ambarita, H.; Abda, S.

    2018-02-01

    This research investigates the performance and emissions of an engine by biogas and gasoline. The experiments use biogas of palm oil mill effluent (POME) with turbocharger at engine loading conditions (100, 200, 300, 400, and 500 Watt). Specific fuel consumption and thermal efficiency are used to compare engine performance, and emission analysis is based on parameters such as carbon monoxide (CO), hydrocarbon (HC), carbon dioxide (CO2) and oxide (O2). The experimental data show that the maximum thermal efficiency when engine use biogas and gasoline is 20.44% and 22.22% respectively. However, there was CO emission reduction significantly when the engine using POME biogas.

  16. Legal provisions governing gaseous effluents radiological monitoring

    International Nuclear Information System (INIS)

    Winkelmann, I.

    1985-01-01

    This contribution explains the main provisions governing radiological monitoring of gaseous effluents from LWR type nuclear power plants. KTA rule 1503.1 defines the measuring methods and tasks to be fulfilled by reactor operators in order to safeguard due monitoring and accounting of radioactive substances in the plants' gaseous effluents. The routine measurements are checked by a supervisory programme by an independent expert. The routine controls include analysis of filter samples, comparative measurement of radioactive noble gases, interlaboratory comparisons, and comparative evaluation of measured values. (DG) [de

  17. Effluent release limits, sources and control

    International Nuclear Information System (INIS)

    Swindell, G.E.

    1977-01-01

    Objectives of radiation protection in relation to releases. Environmental transfer models for radionuclides. Relationship between releases, environmental levels and doses to persons. Establishment of release limits: Limits based on critical population group concept critical pathway analysis and identification of critical group. Limits based on optimization of radiation protection individual dose limits, collective doses and dose commitments 1) differential cost benefit analysis 2) authorized and operational limits taking account of future exposures. Monitoring of releases to the environment: Objectives of effluent monitoring. Typical sources and composition of effluents; design and operation of monitoring programmes; recording and reporting of monitoring results; complementary environmental monitoring. (orig.) [de

  18. A postal survey of effluent generation and disposal in the ...

    African Journals Online (AJOL)

    drinie

    2002-04-02

    Apr 2, 2002 ... smaller than that in South Africa and effluent generation and disposal are still very ... expenditure associated with effluent disposal of about Z$ 24 000 as a yearly average. ..... Technology Review No. 7. Published in the USA ...

  19. Irrigation Suitability Assessment of Effluents From West Kano Rice ...

    African Journals Online (AJOL)

    Choice-Academy

    lake water, and an excess in effluents. The excess nitrates in effluents pollute the lake, but could help as crop .... modelling assessment method proposed in this study can be used to ... economic and environmental impact assessment research ...

  20. Waste analysis plan for the 200 area effluent treatment facility and liquid effluent retention facility

    International Nuclear Information System (INIS)

    Ballantyne, N.A.

    1995-01-01

    This waste analysis plan (WAP) has been prepared for startup of the 200 Area Effluent Treatment Facility (ETF) and operation of the Liquid Effluent Retention Facility (LERF), which are located on the Hanford Facility, Richland, Washington. This WAP documents the methods used to obtain and analyze representative samples of dangerous waste managed in these units, and of the nondangerous treated effluent that is discharged to the State-Approved Land Disposal System (SALDS). Groundwater Monitoring at the SALDS will be addressed in a separate plan

  1. Bioremediation of the textile waste effluent by Chlorella vulgaris

    OpenAIRE

    El-Kassas, Hala Yassin; Mohamed, Laila Abdelfattah

    2014-01-01

    The microalgae biomass production from textile waste effluent is a possible solution for the environmental impact generated by the effluent discharge into water sources. The potential application of Chlorella vulgaris for bioremediation of textile waste effluent (WE) was investigated using 22 Central Composite Design (CCD). This work addresses the adaptation of the microalgae C. vulgaris in textile waste effluent (WE) and the study of the best dilution of the WE for maximum biomass production...

  2. Plant and soil modifications by continuous surface effluent application

    Energy Technology Data Exchange (ETDEWEB)

    Tedesco, M.J.; Levien, R. [Rio Grande do Sul Univ., Porto Alegre, RS (Brazil). Dept. of Solos; Mohrdieck, F.G.; Rodrigues, N.R. [CORSAN-SITEL, Triunfo, RS (Brazil). Polo Petroquimico do Sul. Dept. de Operacao e Manutencao; Flores, A.I.P.

    1993-12-31

    In order to study the effects on soil and plants of the liquid effluent generated by a the Integrated Liquid Effluent Treatment System of a large Brazilian petrochemical complex, a field study was conducted in four areas which received the effluent and compared to control sites. This work presents some results of this study. 12 refs., 1 fig., 3 tabs.

  3. Sulphate removal from industrial effluents through barium sulphate precipitation

    CSIR Research Space (South Africa)

    Swanepoel, H

    2011-11-01

    Full Text Available The pollution of South Africa’s water resources puts a strain on an already stressed natural resource. One of the main pollution sources is industrial effluents such as acid mine drainage (AMD) and other mining effluents. These effluents usually...

  4. Plant and soil modifications by continuous surface effluent application

    Energy Technology Data Exchange (ETDEWEB)

    Tedesco, M J; Levien, R [Rio Grande do Sul Univ., Porto Alegre, RS (Brazil). Dept. of Solos; Mohrdieck, F G; Rodrigues, N R [CORSAN-SITEL, Triunfo, RS (Brazil). Polo Petroquimico do Sul. Dept. de Operacao e Manutencao; Flores, A I.P.

    1994-12-31

    In order to study the effects on soil and plants of the liquid effluent generated by a the Integrated Liquid Effluent Treatment System of a large Brazilian petrochemical complex, a field study was conducted in four areas which received the effluent and compared to control sites. This work presents some results of this study. 12 refs., 1 fig., 3 tabs.

  5. 40 CFR 406.32 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... technology currently available. 406.32 Section 406.32 Protection of Environment ENVIRONMENTAL PROTECTION... Milling Subcategory § 406.32 Effluent limitations guidelines representing the degree of effluent reduction...

  6. 40 CFR 406.42 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... technology currently available. 406.42 Section 406.42 Protection of Environment ENVIRONMENTAL PROTECTION... Milling Subcategory § 406.42 Effluent limitations guidelines representing the degree of effluent reduction...

  7. 40 CFR 406.52 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... technology currently available. 406.52 Section 406.52 Protection of Environment ENVIRONMENTAL PROTECTION... Milling Subcategory § 406.52 Effluent limitations guidelines representing the degree of effluent reduction...

  8. 40 CFR 406.12 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... technology currently available. 406.12 Section 406.12 Protection of Environment ENVIRONMENTAL PROTECTION... Subcategory § 406.12 Effluent limitations guidelines representing the degree of effluent reduction attainable...

  9. 40 CFR 406.33 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... economically achievable. 406.33 Section 406.33 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Subcategory § 406.33 Effluent limitations guidelines representing the degree of effluent reduction attainable...

  10. 40 CFR 406.53 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... economically achievable. 406.53 Section 406.53 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Subcategory § 406.53 Effluent limitations guidelines representing the degree of effluent reduction attainable...

  11. 40 CFR 414.73 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Science.gov (United States)

    2010-07-01

    ... achievable (BAT). 414.73 Section 414.73 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... § 414.73 Effluent limitations representing the degree of effluent reduction attainable by the...

  12. 40 CFR 420.73 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Science.gov (United States)

    2010-07-01

    ... achievable (BAT). 420.73 Section 420.73 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Subcategory § 420.73 Effluent limitations representing the degree of effluent reduction attainable by the...

  13. 40 CFR 410.73 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Science.gov (United States)

    2010-07-01

    ... achievable (BAT). 410.73 Section 410.73 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... § 410.73 Effluent limitations representing the degree of effluent reduction attainable by the...

  14. 40 CFR 424.73 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... economically achievable. 424.73 Section 424.73 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Chromium Subcategory § 424.73 Effluent limitations guidelines representing the degree of effluent reduction...

  15. Climate Change Effect on Thermal Power Cooling in the U.S.

    Science.gov (United States)

    Maintaining reasonable surface-water temperatures is paramount for aquatic ecosystem health. Thermal pollution from power plant effluent can result in unnatural river temperature spikes locally, as well as cause damaging breaches to river temperature. The threat of a nonstationar...

  16. Chromium removal from tanning industries effluents

    International Nuclear Information System (INIS)

    Chaudry, M.A.; Ahmad, S.

    1997-01-01

    Air and water are the basic needs of human being and other living entities on the earth. Tanning industry uses water and some chemicals and so creates environmental problems, depending basically on two principal sources, hide and water. The processes of tanning are based on chromium sulphate and vegetable treatment of hide. According to the national environmental quality standards (NEQS) the effluent or disposed water should contain phenol less than 0.5 ppm, Cr, sulphates, chloride and other salts content. About 30-40 liters of water are used to process one Kg of raw hide into finished goods. Total installed capacity of hides and skins chrome tanning is 53.5 million square meter, earning a large amount of foreign exchange for our country. In the present work, seven tanning industries effluents from the suburbs of Multan city have been collected and analysed. The pH of the liquors have been found to vary from 2.72 to 4.4 and the constituent Cr have been found to be from zero to 8000 ppm from vegetable to chrome tanning industrial effluents studied. The stages involved in tanning and treatment of the effluent water waste including chemical treatment of Cr has been described with a special reference to supported liquid membranes process for removal of chromium ions. (author)

  17. Simulation of ammoniacal nitrogen effluent using feedforward ...

    African Journals Online (AJOL)

    Ammoniacal nitrogen in domestic wastewater treatment plants has recently been added as the monitoring parameter by the Department of Environment, Malaysia. It is necessary to obtain a suitable model for the simulation of ammonical nitrogen in the effluent stream of sewage treatment plant in order to meet the new ...

  18. Benthos of Cochin backwaters receiving industrial effluents

    Digital Repository Service at National Institute of Oceanography (India)

    Devi, K.S.; Venugopal, P.

    into the river. This stretch with a station 2 km further upstream forms the area of study. Faunal groups/species are rich at barmouth (st 1), gradually decline upstream and record lowest density at the effluent discharge point (st 8). Five major and 26 other...

  19. Wastewater effluent dispersal in Southern California Bays

    KAUST Repository

    Uchiyama, Yusuke; Idica, Eileen Y.; McWilliams, James C.; Stolzenbach, Keith D.

    2014-01-01

    The dispersal and dilution of urban wastewater effluents from offshore, subsurface outfalls is simulated with a comprehensive circulation model with downscaling in nested grid configurations for San Pedro and Santa Monica Bays in Southern California during Fall of 2006. The circulation is comprised of mean persistent currents, mesoscale and submesoscale eddies, and tides. Effluent volume inflow rates at Huntington Beach and Hyperion are specified, and both their present outfall locations and alternative nearshore diversion sites are assessed. The effluent tracer concentration fields are highly intermittent mainly due to eddy currents, and their probability distribution functions have long tails of high concentration. The dilution rate is controlled by submesoscale stirring and straining in tracer filaments. The dominant dispersal pattern is alongshore in both directions, approximately along isobaths, over distances of more than 10. km before dilution takes over. The current outfall locations mostly keep the effluent below the surface and away from the shore, as intended, but the nearshore diversions do not. © 2014 Elsevier Ltd.

  20. THE EFFECT OF REFINERY AND PETROCHEMICAL EFFLUENT ...

    African Journals Online (AJOL)

    Dr Osondu

    Ethiopian Journal of Environmental Studies and Management Vol. ... This study investigated the effects of treated effluent discharge on the water quality of Ubeji Creek ... the ineffectiveness of purification systems, waste ..... a receiving watershed in a typical rural community. ... eastern economy, practice of hall of India private.

  1. Behaviour of radioiodine in gaseous effluents

    International Nuclear Information System (INIS)

    Barry, P.J.

    1968-01-01

    Because of the different chemical forms in which radioiodine occurs in the gaseous state, it is important when designing efficient filters to know the chemical forms which may be present in the effluent gases when various operations are being carried out and to know the effect of different gaseous environments on the filtration efficiency. To obtain this information it is necessary to have available reliable means of characterizing different chemical forms and to sample gaseous effluents when these operations are being carried out. This paper describes the use for identifying molecular iodine of metallic screens in a multi-component sampling pack in different gaseous environments. Using multi-component sampling packs, the fractionation of iodine nuclides between different chemical forms was measured in the effluent gases escaping from an in-pile test loop in which the fuel was deliberately ruptured by restricting the flow of coolant. Sequential samples were taken for six hours after the rupture and it was possible to follow during this period the individual behaviours of 13 '1I, 133 I and 135 I. Simultaneous samples were also obtained of the noble gases in the effluent gas stream and of the iodine nuclides in the loop coolant. Similar experiments have been carried out with a view to characterizing the different chemical behaviour of radioiodine as it is released from a variety of operations in the nuclear industry including the cutting of fuel sections in metallurgical examination caves and an incinerator. (author)

  2. Sewage Effluent Infiltrates Frozen Forest Soil

    Science.gov (United States)

    Alfred Ray Harris

    1976-01-01

    Secondarily treated sewage effluent, applied at the rate of 1 and 2 inches per week, infiltrated a frozen Sparta sand soil forested with jack pine and scrub oak. Maximum frost depth in treated plots averaged 60 cm and in check plots averages 35 cm. Nitrogen was mobile with some accumulation. Phosphorus was absorbed.

  3. Anaerobic effluent disinfection using ozone: Byproducts formation

    NARCIS (Netherlands)

    Silva, G.H.R.; Daniel, L.A.; Bruning, H.; Rulkens, W.H.

    2010-01-01

    This research was aimed at studying oxidation processes, coliform inactivation effectiveness and disinfection byproducts (DBPs) associated with the disinfection of anaerobic sanitary wastewater effluent with ozone applied at doses of 5.0, 8.0 and 10.0mg O(3)L(-1) for contact times of 5, 10 and 15

  4. Decentralised wastewater treatment effluent fertigation: preliminary ...

    African Journals Online (AJOL)

    2018-04-02

    Apr 2, 2018 ... The experimental site at Newlands-Mashu Research Facility, located in Durban ... Samples of effluent used during the study were collected from the AF ... Yield parameters of banana (number and mass of true fingers ..... GHOREISHI M, HOSSINI Y and MAFTOON M (2012) Simple models for predicting leaf ...

  5. EFFECTS OF REFINERY EFFLUENT ON THE PHYSICO ...

    African Journals Online (AJOL)

    PROMOTING ACCESS TO AFRICAN RESEARCH. AFRICAN JOURNALS ONLINE ... Abstract. Managing oil and gas industrial environment requires constant monitoring of the effluent discharges from such industries. The essence of such ... Full Text: EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT · DOWNLOAD FULL ...

  6. Wastewater effluent dispersal in Southern California Bays

    KAUST Repository

    Uchiyama, Yusuke

    2014-03-01

    The dispersal and dilution of urban wastewater effluents from offshore, subsurface outfalls is simulated with a comprehensive circulation model with downscaling in nested grid configurations for San Pedro and Santa Monica Bays in Southern California during Fall of 2006. The circulation is comprised of mean persistent currents, mesoscale and submesoscale eddies, and tides. Effluent volume inflow rates at Huntington Beach and Hyperion are specified, and both their present outfall locations and alternative nearshore diversion sites are assessed. The effluent tracer concentration fields are highly intermittent mainly due to eddy currents, and their probability distribution functions have long tails of high concentration. The dilution rate is controlled by submesoscale stirring and straining in tracer filaments. The dominant dispersal pattern is alongshore in both directions, approximately along isobaths, over distances of more than 10. km before dilution takes over. The current outfall locations mostly keep the effluent below the surface and away from the shore, as intended, but the nearshore diversions do not. © 2014 Elsevier Ltd.

  7. Gamma irradiation treatment of secondary sewage effluent

    International Nuclear Information System (INIS)

    Vajdic, A.H.

    The operation and monitoring of a pilot scale Co-60 gamma irradiation unit treating secondary sewage effluent is described. The disinfecting efficiency of the unit is compared to that of an experimental 'ideal' chlorination unit and to the plant chlorination process. A cost estimate for disinfection by gamma irradiation on a full plant scale is included. (author)

  8. Introduction to Effluent Treatment and Industrial Methods

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 5; Issue 11. Techniques of WasteWater Treatment - Introduction to Effluent Treatment and Industrial Methods. Amol A Kulkarni Mugdha Deshpande A B Pandit. General Article Volume 5 Issue 11 November 2000 pp 56-68 ...

  9. Microbial degradation of textile industrial effluents | Palamthodi ...

    African Journals Online (AJOL)

    Textile waste water is a highly variable mixture of many polluting substance ranging from inorganic compounds and elements to polymers and organic products. To ensure the safety of effluents, proper technologies need to be used for the complete degradation of dyes. Traditionally, treatments of textile waste water involve ...

  10. Short communication: Industrial effluent treatments using heavy ...

    African Journals Online (AJOL)

    Bioflocculants produced by Herbaspirillium sp. CH7, Paenibacillus sp. CH11, Bacillus sp. CH15 and a Halomonas sp. were preliminarily evaluated as flocculating agents in the treatment of industrial wastewater effluents. Industrial (1 local chemical-industry and 2 textile-industry: Biavin 109-medium blue dye and Whale dye) ...

  11. Effluent and water treatment at AERE Harwell

    International Nuclear Information System (INIS)

    Lewis, J.B.

    1977-01-01

    The treatment of liquid wastes at Harwell is based on two main principles: separation of surface water, domestic sewage, trade wastes and radioactive effluents at source, and a system of holding tanks which are sampled so that the appropriate treatment can be given to any batch. All discharges are subject to independent monitoring by the authorising departments and the Thames Water Inspectors. (author)

  12. POLLUTION EFFECT OF FOOD AND BEVERAGES EFFLUENTS ...

    African Journals Online (AJOL)

    Preferred Customer

    UV-Visible spectrophotometer (model CE 2501, 2000 series). Nickel ..... The level of nitrate in the effluent varied between 32.1 mg/L and 58.4 mg/L. These levels ..... Institute of Social and Economic Research, Ibadan, Nigeria; 1986; p 234. 9.

  13. Remediation of feedlot effluents using aquatic plants

    OpenAIRE

    Rizzo, Pedro Federico; Arreghini, Silvana; Serafini, Roberto José María; Bres, Patricia Alina; Crespo, Diana Elvira; Fabrizio de Iorio, Alicia Rosa

    2012-01-01

    Feedlots have increased in several regions of Argentina, particularly in the Pampas. The absence of adequate treatments of the effluents produced in these establishments creates serious problems to the society. Phytoremediation can be defined as inexpensive and environmentally sustainable strategy used to remove pollutants by plants. The aim of this study was to evaluate the remediation potential of two ...

  14. Statistical evaluation of effluent monitoring data for the 200 Area Treated Effluent Disposal Facility

    International Nuclear Information System (INIS)

    Chou, C.J.; Johnson, V.G.

    2000-01-01

    The 200 Area Treated Effluent Disposal Facility (TEDF) consists of a pair of infiltration basins that receive wastewater originating from the 200 West and 200 East Areas of the Hanford Site. TEDF has been in operation since 1995 and is regulated by State Waste Discharge Permit ST 4502 (Ecology 1995) under the authority of Chapter 90.48 Revised Code of Washington (RCW) and Washington Administrative Code (WAC) Chapter 173-216. The permit stipulates monitoring requirements for effluent (or end-of-pipe) discharges and groundwater monitoring for TEDF. Groundwater monitoring began in 1992 prior to TEDF construction. Routine effluent monitoring in accordance with the permit requirements began in late April 1995 when the facility began operations. The State Waste Discharge Permit ST 4502 included a special permit condition (S.6). This condition specified a statistical study of the variability of permitted constituents in the effluent from TEDF during its first year of operation. The study was designed to (1) demonstrate compliance with the waste discharge permit; (2) determine the variability of all constituents in the effluent that have enforcement limits, early warning values, and monitoring requirements (WHC 1995); and (3) determine if concentrations of permitted constituents vary with season. Additional and more frequent sampling was conducted for the effluent variability study. Statistical evaluation results were provided in Chou and Johnson (1996). Parts of the original first year sampling and analysis plan (WHC 1995) were continued with routine monitoring required up to the present time

  15. Physiochemical Treatment of Textile Industry Effluents

    International Nuclear Information System (INIS)

    Latif, M. I.; Qazi, M. A.; Khan, H.; Ahmad, N.

    2015-01-01

    The study mainly focuses on the application of chemical Coagulants (Lime, Alum and Ferrous Sulfate) and Advanced Oxidation Processes (AOPs) (Ozone Treatment and Fenton Process, alone and in combination) to treat textile industry effluents, optimization of coagulation process for various Coagulants in terms of process conditions, including coagulant dose, pH and settling time. The results revealed that Alum was most effective. The efficiency of coagulation process was dose dependent and 400 mg/L dose of Alum alone showed maximum color removal of 47%, 57% and 54% of yellow, red and blue dyes, respectively in addition to the COD removal of 44%. The combined applications of Alum and Lime (300:75 mg/L) and Lime and Alum (300:75 mg/L) showed slightly better COD removal of 51%. However, color removal efficiency of all coagulants was at par. The Ozonation process appeared the most promising for the treatment of waste water and color/COD removal, the efficiency of which increased with increasing the treatment time at constant Ozone dose. For less polluted effluents, 97% color removal was obtained after 1 minute and after 15 minutes for highly polluted effluents; The COD removal efficiency of the process for less polluted effluents was around 89% after 5 minutes Ozonation and for highly polluted effluents 88% COD removal after 40 minutes. The performance of Fenton process was extremely low as compared to Ozonation process. Increase in pH, significantly decreased the color removal efficiency of the process. COD removal efficiency of Fenton process increased with an increase in settling time. (author)

  16. Facility effluent monitoring plan for the fast flux test facility

    International Nuclear Information System (INIS)

    Nickels, J.M.; Dahl, N.R.

    1992-11-01

    A facility effluent monitoring plan is required by the US Department of Energy in US Department of Energy Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could affect employee or public safety or the environment. A Facility Effluent Monitoring Plan determination was performed during calendar year 1991 and the evaluation requires the need for a facility effluent monitoring plan. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements

  17. Effect of Lakhara chemical power station (LPTS) effluents on the river Indus water quality

    International Nuclear Information System (INIS)

    Mahar, R.B.; Memon, H.M.; Khushwar, M.Y.

    2000-01-01

    The variation of the quality of river Indus water with respect to the seasonal changes, discharge of water and dilution with the effluents of Lakhra Thermal Power Station (LTPS), has been monitored. The studies were focussed on the river Indus water quality before and after mixing the effluents of the power station. The samples were collected monthly from the representative locations of the river Indus, and analyzed for the residues (total, filterable, non-filterable, volatile and fixed), pH, temperature (air and water), conductance, chloride, hardness, alkalinity, dissolved oxygen (DO), chemical oxygen demand (COD), biochemical oxygen demand (BOD) /sub 5/- nitrate, phosphate, sulfate, ammonia, ammonium, silicates, magnesium, potassium, calcium and sodium. The results have been compared with the permissible limits of ECC (European Economic Community) standards for drinking and surface water. (author)

  18. Effluent releases at the TRIGA reactor facility

    Energy Technology Data Exchange (ETDEWEB)

    Whittemore, W L [General Atomic Co., San Diego, CA (United States)

    1974-07-01

    The principal effluent from the operating TRIGA reactors in our facility is argon-41. As monitored by a recording gas and particulate stack monitor, the values shown in the table, the Mark III operating 24 hours per day for very long periods produced the largest amount of radioactive argon. The quantity of 23.7 Ci A-41 when diluted by the normal reactor room ventilation system corresponded to 1.45 x 10{sup -6} {mu}Ci/cc. As diluted in the roof stack stream and the reactor building wake, the concentration immediately outside the reactor building was 25% MPC for an unrestricted area. The continued dilution of this effluent resulted in a concentration of a few percent MPC at the site boundary (unrestricted area) 350 meters from the reactor. (author)

  19. Electrocoagulation of Palm Oil Mill Effluent

    Science.gov (United States)

    Agustin, Melissa B.; Sengpracha, Waya P.; Phutdhawong, Weerachai

    2008-01-01

    Electrocoagulation (EC) is an electrochemical technique which has been employed in the treatment of various kinds of wastewater. In this work the potential use of EC for the treatment of palm oil mill effluent (POME) was investigated. In a laboratory scale, POME from a factory site in Chumporn Province (Thailand) was subjected to EC using aluminum as electrodes and sodium chloride as supporting electrolyte. Results show that EC can reduce the turbidity, acidity, COD, and BOD of the POME as well as some of its heavy metal contents. Phenolic compounds are also removed from the effluent. Recovery techniques were employed in the coagulated fraction and the recovered compounds was analysed for antioxidant activity by DPPH method. The isolate was found to have a moderate antioxidant activity. From this investigation, it can be concluded that EC is an efficient method for the treatment of POME. PMID:19139537

  20. Ion exchange for treatment of industrial effluents

    International Nuclear Information System (INIS)

    Moreno Daudinot, Aurora Maria; Ge Leyva, Midalis

    2016-01-01

    The acid leaching and ammoniacal carbonate technologies of laterite respectively, are responsible for the low quality of life of the local population, the big deforested areas due to the mining tilling, the elevated contents of solids in the air and waters, as well as the chemical contamination by metals presence, the acidity or basicity of the effluents of both industries, that arrive through the river and the bay to aquifer's mantle. The ion exchange resins allow ions separation contained in low concentrations in the solutions, where the separation of these elements for solvents, extraction or another chemical methods would be costly. Technological variants are proposed in order to reduce the impact produced on the flora and the fauna, by the liquid effluents of nickel industry, by means of ion exchange resins introduction as well as the recuperation of metals and their re incorporation to the productive process. (Author)

  1. Reuse of wastewater effluents in Saudi Arabia

    International Nuclear Information System (INIS)

    Ishaq, A.M.; Al-Suwaiyan, M.S.

    2002-01-01

    In the initial phase of a six-year study, laboratory investigations were carried out to establish conservative estimates of the contaminant removals that are possible by the recharge of local secondary effluents through a sand dune. In the preliminary laboratory study, chlorinated effluent was found to be more suitable than unchlorinated wastewater with respect to the development of anaerobic conditions and headlosses. In the main laboratory study, a 5-m high Plexiglass sand box column was used to investigate conservative predictions for the removal of contaminants. The average removals of BOD, COD, and TOC were over 65%, 65%, and 55%, respectively. The COD was primarily removed in the first 200 cm of the column. The effluent had a residual TOC of 1.66 mg/l and consisted of humic substances. The average removal of microbial indicator organisms: Total Coliform (TC) and Coliphage were over 85% and 66%, respectively. The product water contained only nominal amounts of TC (Average - 21.5 MPN/100 ml) and Coliphage (Average - 6 PFU/100 ml). The porous media largely remained unaffected by the recharge operation. In the second phase, a 'field recharge system' was constructed and recharge operations were carried out over a two year period resulting in the following observations. a. The quality of the end product will depend entirely on the quality of the secondary effluent. b. With the soil aquifer treatment system (SATS) under consideration, it was possible to achieve product water meeting the recharge standards with respect to heavy metals, pH, BOD, TOC, fecal coliform and total coliform. c. The product water met the standards for restricted and unrestricted irrigation. (author)

  2. IRSN's expertise about nuclear medicine hospital effluents

    International Nuclear Information System (INIS)

    2009-01-01

    This brief note aims at presenting the radioactivity follow up of hospital effluents performed by the French Institute of Radiation Protection and Nuclear Safety (IRSN). This follow up concerns the radioactive compounds and radiopharmaceuticals used in nuclear medicine, and principally technetium 99 and iodine 131. The IRSN has developed a network of remote measurement systems for the monitoring of sewers and waste water cleaning facilities. Data are compiled in a data base for analysis and subsequent expertise. (J.S.)

  3. Wastes, effluents and pollution. impact on environment

    International Nuclear Information System (INIS)

    Ngo, Ch.; Regent, A.

    2008-01-01

    From concrete examples, the authors explain the nature, and the place of different pollution and wastes sources in our environment and the risks that make run. They bring some tracks to our modern communities that must react and imagine remedial actions to manage wastes, effluents and pollutions in order to make them harmless; this new edition enriches of a chapter on health and hygiene problems induced by the different contaminations of environment. (N.C.)

  4. Hazard Baseline Downgrade Effluent Treatment Facility

    International Nuclear Information System (INIS)

    Blanchard, A.

    1998-01-01

    This Hazard Baseline Downgrade reviews the Effluent Treatment Facility, in accordance with Department of Energy Order 5480.23, WSRC11Q Facility Safety Document Manual, DOE-STD-1027-92, and DOE-EM-STD-5502-94. It provides a baseline grouping based on the chemical and radiological hazards associated with the facility. The Determination of the baseline grouping for ETF will aid in establishing the appropriate set of standards for the facility

  5. Reuse of wastewater effluents in Saudi Arabia

    Energy Technology Data Exchange (ETDEWEB)

    Ishaq, A.M.; Al-Suwaiyan, M.S. [King Fahd Univ. of Petroleum and Minerals, Dept. of Civil Engineering, Dhahran (Saudi Arabia)

    2002-06-15

    In the initial phase of a six-year study, laboratory investigations were carried out to establish conservative estimates of the contaminant removals that are possible by the recharge of local secondary effluents through a sand dune. In the preliminary laboratory study, chlorinated effluent was found to be more suitable than unchlorinated wastewater with respect to the development of anaerobic conditions and headlosses. In the main laboratory study, a 5-m high Plexiglass sand box column was used to investigate conservative predictions for the removal of contaminants. The average removals of BOD, COD, and TOC were over 65%, 65%, and 55%, respectively. The COD was primarily removed in the first 200 cm of the column. The effluent had a residual TOC of 1.66 mg/l and consisted of humic substances. The average removal of microbial indicator organisms: Total Coliform (TC) and Coliphage were over 85% and 66%, respectively. The product water contained only nominal amounts of TC (Average - 21.5 MPN/100 ml) and Coliphage (Average - 6 PFU/100 ml). The porous media largely remained unaffected by the recharge operation. In the second phase, a 'field recharge system' was constructed and recharge operations were carried out over a two year period resulting in the following observations. a. The quality of the end product will depend entirely on the quality of the secondary effluent. b. With the soil aquifer treatment system (SATS) under consideration, it was possible to achieve product water meeting the recharge standards with respect to heavy metals, pH, BOD, TOC, fecal coliform and total coliform. c. The product water met the standards for restricted and unrestricted irrigation. (author)

  6. Separation of tritium from aqueous effluents

    International Nuclear Information System (INIS)

    Geens, L.; Bruggeman, A.; Meynendonckx, L.; Parmentier, C.; Belien, H.; Ooms, E.; Smets, D.; Stevens, J.; van Vlerken, J.

    1988-01-01

    From 1975 until 1982 - within the framework of the CEC indirect action programme on management and storage of radioactive waste - the SCK/CEN has developed the ELEX process from laboratory scale experiments up to the construction of an integrated pilot installation. The ELEX process combines water electrolysis and catalytical isotope exchange for the separation of tritium from aqueous reprocessing effluents by isotope enrichment. Consequently, the pilot installation consists of two main parts: an 80 kW water electrolyser and a 10 cm diameter trickle bed exchange column. The feed rate of tritiated water amounts to 5 dm 3 .h -1 , containing up to 3.7 GBq.dm -3 of tritium. This report describes the further development of the process during the second phase of the second programme. Three main items are reported: (i) research work in the field of pretreatment of real reprocessing effluents, before feeding them to an ELEX installation; (ii) demonstration of the technical feasibility of the ELEX process with simulated active effluent streams in the pilot installation; (iii) a cost estimation for the ELEX installation, comprising the required investments and the annual operation costs

  7. Facility effluent monitoring plan for the plutonium uranium extraction facility

    Energy Technology Data Exchange (ETDEWEB)

    Wiegand, D.L.

    1994-09-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438-01. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated at a minimum of every three years.

  8. Facility Effluent Monitoring Plan for the uranium trioxide facility

    International Nuclear Information System (INIS)

    Lohrasbi, J.; Johnson, D.L.; De Lorenzo, D.S.

    1993-12-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438-01. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated at a minimum of every three years

  9. Facility effluent monitoring plan determinations for the 200 Area facilities

    International Nuclear Information System (INIS)

    Nickels, J.M.

    1991-11-01

    The following facility effluent monitoring plan determinations document the evaluations conducted for the Westinghouse Hanford Company 200 Area facilities (chemical processing, waste management, 222-S Laboratory, and laundry) on the Hanford Site in south central Washington State. These evaluations determined the need for facility effluent monitoring plans for the 200 Area facilities. The facility effluent monitoring plan determinations have been prepared in accordance with A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438 (WHC 1991). The Plutonium/Uranium Extraction Plant and UO 3 facility effluent monitoring plan determinations were prepared by Los Alamos Technical Associates, Richland, Washington. The Plutonium Finishing Plant, Transuranic Waste Storage and Assay Facility, T Plant, Tank Farms, Low Level Burial Grounds, and 222-S Laboratory determinations were prepared by Science Applications International Corporation of Richland, Washington. The B Plant Facility Effluent Monitoring Plan Determination was prepared by ERCE Environmental Services of Richland, Washington

  10. Facility effluent monitoring plan for 242-A Evaporator facility

    International Nuclear Information System (INIS)

    Crummel, G.M.; Gustavson, R.D.

    1993-03-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1* for any operations that involve hazardous materials and radioactive substances that could affect employee or public safety or the environment. A facility effluent monitoring plan determination was performed during Calendar Year 1991 and the evaluation showed the need for a facility effluent monitoring plan. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility effluent Monitoring Plans, WHC-EP-0438-1**. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements

  11. Desalination of effluent using fin type solar still

    Energy Technology Data Exchange (ETDEWEB)

    Velmurugan, V. [Department of Mechanical Engineering, Infant Jesus College of Engineering, Thoothukudi, Tamil Nadu 628 851 (India); Deenadayalan, C.K.; Vinod, H.; Srithar, K. [Department of Mechanical Engineering, Thiagarajar College of Engineering, Madurai, Tamil Nadu 625 015 (India)

    2008-11-15

    In this work, an attempt is made to produce potable water from industrial effluents. An ordinary basin type solar still integrated with fins at the basin plate is used for experimentation. Since industrial effluent is used as feed, before this still, an effluent settling tank is provided to get clarified effluent. This effluent settling tank is fabricated with three chambers, consists of pebble, coal and sand for settling the impurities and removing the bacteria in the effluents. Sponges, pebbles, black rubber and sand are used in the fin type single basin solar still for enhancing the yield. Results show that the productivity increases considerably due to this modification. A theoretical analysis is also carried out which, closely converges with experimental results. The economic analysis proved that the approximate payback period of such kinds of still is 1 year. (author)

  12. Facility effluent monitoring plan for the plutonium uranium extraction facility

    International Nuclear Information System (INIS)

    Wiegand, D.L.

    1994-09-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438-01. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated at a minimum of every three years

  13. Nutrient removal from swine lagoon effluent by duckweed

    Energy Technology Data Exchange (ETDEWEB)

    Bergmann, B.A.; Cheng, J.; Classen, J.; Stomp, A.M.

    2000-04-01

    Three duckweed geographic isolates were grown on varying concentrations of swine lagoon effluent in a greenhouse to determine their ability to remove nutrients from the effluent. Duckweed biomass was harvested every other day over a 12-day period. Duckweed biomass production, nutrient loss from the swine lagoon effluent, and nutrient content of duckweed biomass were used to identify effluent concentrations/geographic isolate combinations that are effective in terms of nutrient utilization from swine lagoon effluent and production of healthy duckweed biomass. When Lemna minor geographic isolate 8627 was grown on 50% swine lagoon effluent, respective losses of TKN, NH{sub 3}-N, TP, OPO{sub 4}-P, TOC, K, Cu, and Zn were 83, 100, 49, 31, 68, 21, 28 and 67%.

  14. Facility effluent monitoring plan for the Plutonium Uranium Extraction Facility

    International Nuclear Information System (INIS)

    Greager, E.M.

    1997-01-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438-01. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether these systems are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan will ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated, at a minimum, every 3 years

  15. Facility effluent monitoring plan for the B plant

    International Nuclear Information System (INIS)

    Lesser, J.E.

    1994-09-01

    A facility effluent monitoring plan is required by the U.S. Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438-1. This facility effluent monitoring plant assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated every three years

  16. Hanford Facility dangerous waste permit application, liquid effluent retention facility and 200 area effluent treatment facility

    Energy Technology Data Exchange (ETDEWEB)

    Coenenberg, J.G.

    1997-08-15

    The Hanford Facility Dangerous Waste Permit Application is considered to 10 be a single application organized into a General Information Portion (document 11 number DOE/RL-91-28) and a Unit-Specific Portion. The scope of the 12 Unit-Specific Portion is limited to Part B permit application documentation 13 submitted for individual, `operating` treatment, storage, and/or disposal 14 units, such as the Liquid Effluent Retention Facility and 200 Area Effluent 15 Treatment Facility (this document, DOE/RL-97-03). 16 17 Both the General Information and Unit-Specific portions of the Hanford 18 Facility Dangerous Waste Permit Application address the content of the Part B 19 permit application guidance prepared by the Washington State Department of 20 Ecology (Ecology 1987 and 1996) and the U.S. Environmental Protection Agency 21 (40 Code of Federal Regulations 270), with additional information needs 22 defined by the Hazardous and Solid Waste Amendments and revisions of 23 Washington Administrative Code 173-303. For ease of reference, the Washington 24 State Department of Ecology alpha-numeric section identifiers from the permit 25 application guidance documentation (Ecology 1996) follow, in brackets, the 26 chapter headings and subheadings. A checklist indicating where information is 27 contained in the Liquid Effluent Retention Facility and 200 Area Effluent 28 Treatment Facility permit application documentation, in relation to the 29 Washington State Department of Ecology guidance, is located in the Contents 30 Section. 31 32 Documentation contained in the General Information Portion is broader in 33 nature and could be used by multiple treatment, storage, and/or disposal units 34 (e.g., the glossary provided in the General Information Portion). Wherever 35 appropriate, the Liquid Effluent Retention Facility and 200 Area Effluent 36 Treatment Facility permit application documentation makes cross-reference to 37 the General Information Portion, rather than duplicating

  17. Hanford Facility dangerous waste permit application, liquid effluent retention facility and 200 area effluent treatment facility

    International Nuclear Information System (INIS)

    Coenenberg, J.G.

    1997-01-01

    The Hanford Facility Dangerous Waste Permit Application is considered to 10 be a single application organized into a General Information Portion (document 11 number DOE/RL-91-28) and a Unit-Specific Portion. The scope of the 12 Unit-Specific Portion is limited to Part B permit application documentation 13 submitted for individual, 'operating' treatment, storage, and/or disposal 14 units, such as the Liquid Effluent Retention Facility and 200 Area Effluent 15 Treatment Facility (this document, DOE/RL-97-03). 16 17 Both the General Information and Unit-Specific portions of the Hanford 18 Facility Dangerous Waste Permit Application address the content of the Part B 19 permit application guidance prepared by the Washington State Department of 20 Ecology (Ecology 1987 and 1996) and the U.S. Environmental Protection Agency 21 (40 Code of Federal Regulations 270), with additional information needs 22 defined by the Hazardous and Solid Waste Amendments and revisions of 23 Washington Administrative Code 173-303. For ease of reference, the Washington 24 State Department of Ecology alpha-numeric section identifiers from the permit 25 application guidance documentation (Ecology 1996) follow, in brackets, the 26 chapter headings and subheadings. A checklist indicating where information is 27 contained in the Liquid Effluent Retention Facility and 200 Area Effluent 28 Treatment Facility permit application documentation, in relation to the 29 Washington State Department of Ecology guidance, is located in the Contents 30 Section. 31 32 Documentation contained in the General Information Portion is broader in 33 nature and could be used by multiple treatment, storage, and/or disposal units 34 (e.g., the glossary provided in the General Information Portion). Wherever 35 appropriate, the Liquid Effluent Retention Facility and 200 Area Effluent 36 Treatment Facility permit application documentation makes cross-reference to 37 the General Information Portion, rather than duplicating

  18. The use of artificial wetlands to treat greenhouse effluents

    OpenAIRE

    Lévesque, Vicky; Dorais, Martine; Gravel, Valérie; Ménard, Claudine; Antoun, Hani; Rochette, Philippe; Roy, Stéphane

    2011-01-01

    Untreated greenhouse effluents or leak solution constitute a major environmental burden because their nitrate and phosphate concentrations may induce eutrophication. Artificial wetlands may offer a low cost alternative treatment of greenhouse effluents and consequently improve the sustainability of greenhouse growing systems. The objectives of this study were to 1) characterize the efficiency of different types of wetland to reduce ion content of greenhouse tomato effluent, and 2) improve the...

  19. Quality Assurance Project Plan for Facility Effluent Monitoring Plan activities

    International Nuclear Information System (INIS)

    Frazier, T.P.

    1994-01-01

    This Quality Assurance Project Plan addresses the quality assurance requirements for the activities associated with the Facility Effluent Monitoring Plans, which are part of the overall Hanford Site Environmental Protection Plan. This plan specifically applies to the sampling and analysis activities and continuous monitoring performed for all Facility Effluent Monitoring Plan activities conducted by Westinghouse Hanford Company. It is generic in approach and will be implemented in conjunction with the specific requirements of the individual Facility Effluent Monitoring Plans

  20. Effects of heated effluents on the reproduction of selected species of the Centrarchid family. Progress report, October 26, 1975--October 25, 1976

    International Nuclear Information System (INIS)

    Clugston, J.P.; Provost, E.E.

    1975-01-01

    Progress is reported on the effects of thermal effluents on the development of gametes in the bluegill, Lepomis macrochirus; on uptake of the trace metal contaminants, Cd, Cr, and Pb by fishes; on food habits of the bluegill and the largemouth bass, Microptems salmoides; on the distribution of fishes in cooling reservoirs; and on the behavior of the largemouth bass

  1. Potential for reuse of effluent from fish-processing industries

    Directory of Open Access Journals (Sweden)

    Luana Morena Rodrigues Vitor Dias Ferraciolli

    2017-09-01

    Full Text Available The most common problems in the fish processing industry relate to high water consumption and the generation of effluents with concentrated organic loads. Given that reuse can represent an alternative for sustainable development, this study sought to assess the potential for recycling effluents produced in a fish-processing plant. In order to do so, the final industrial effluent was analyzed using the American Public Health Association (APHA standard effluent-analysis method (2005. In addition, the study assessed treatments which produce effluents meeting the requirements prescribed by different countries' regulations for reuse and recycling. The results found that effluents with smaller organic loads, such as those from health barriers and monoblock washing, can be treated in order to remove nutrients and solids so that they can be subsequently reused. For effluents produced by the washing and gutting cylinders, it is recommended that large fragments of solid waste be removed beforehand. Effluents can in this way attain a quality compatible with industrial reuse. This study further highlights the possibility of treating effluents so as comply with drinking water standards. This would potentially allow them to be used within the actual fish-processing procedure; in such a case, a revision of standards and measures for controlling use should be considered to prevent microbiological damage to products and risks to handlers and final consumers.

  2. Liquid effluent retention facility dangerous waste permit application

    International Nuclear Information System (INIS)

    1991-06-01

    This appendix to the Liquid Effluent Retention Facility Dangerous Waste Permit Application contains pumps, piping, leak detection systems, geomembranes, leachate collection systems, earthworks and floating cover systems

  3. Quality Assurance Program Plan for FFTF effluent controls. Revision 1

    International Nuclear Information System (INIS)

    Seamans, J.A.

    1995-01-01

    This Quality Assurance Program Plan is specific to environmental related activities within the FFTF Property Protected Area. The activities include effluent monitoring and Low Level Waste Certification

  4. Facility effluent monitoring plan for the tank farm facility

    Energy Technology Data Exchange (ETDEWEB)

    Crummel, G.M.

    1998-05-18

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements.

  5. A guide for preparing Hanford Site facility effluent monitoring plans

    International Nuclear Information System (INIS)

    Nickels, J.M.

    1992-06-01

    This document provides guidance on the format and content of effluent monitoring plans for facilities at the Hanford Site. The guidance provided in this document is designed to ensure compliance with US Department of Energy (DOE) Orders 5400.1 (DOE 1988a), 5400.3 (DOE 1989a), 5400.4 (DOE 1989b), 5400.5 (DOE 1990a), 5480.1 (DOE 1982), 5480.11 (DOE 1988b), and 5484.1 (DOE 1981). These require environmental monitoring plans for each site, facility, or process that uses, generates, releases, or manages significant pollutants of radioactive or hazardous materials. In support of DOE Orders 5400.5 (Radiation Protection of the Public and the Environment) and 5400.1 (General Environmental Protection Program), the DOE Environmental Regulatory Guide for Radiological Effluent Monitoring and Environmental Surveillance (DOE 1991) should be used to establish elements of a radiological effluent monitoring program in the Facility Effluent Monitoring Plan. Evaluation of facilities for compliance with the US Environmental Protection Agency Clean Air Act of 1977 requirements also is included in the airborne emissions section of the Facility Effluent Monitoring Plans. Sampling Analysis Plans for Liquid Effluents, as required by the Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement), also are included in the Facility Effluent Monitoring Plans. The Facility Effluent Monitoring Plans shall include complete documentation of gaseous and liquid effluent sampling and monitoring systems

  6. Facility effluent monitoring plan determinations for the 400 Area facilities

    International Nuclear Information System (INIS)

    Nickels, J.M.

    1991-09-01

    This Facility Effluent Monitoring Plan determination resulted from an evaluation conducted for the Westinghouse Hanford Company 400 Area facilities on the Hanford Site. The Facility Effluent Monitoring Plan determinations have been prepared in accordance with A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans. Two major Westinghouse Hanford Company facilities in the 400 Area were evaluated: the Fast Flux Test Facility and the Fuels Manufacturing and examination Facility. The determinations were prepared by Westinghouse Hanford Company. Of these two facilities, only the Fast Flux Test Facility will require a Facility Effluent Monitoring Plan. 7 refs., 5 figs., 4 tabs

  7. Quality Assurance Project Plan for Facility Effluent Monitoring Plan activities

    International Nuclear Information System (INIS)

    Nickels, J.M.

    1991-06-01

    This Quality Assurance Project Plan addresses the quality assurance requirements for the Facility Monitoring Plans of the overall site-wide environmental monitoring plan. This plan specifically applies to the sampling and analysis activities and continuous monitoring performed for all Facility Effluent Monitoring Plan activities conducted by Westinghouse Hanford Company. It is generic in approach and will be implemented in conjunction with the specific requirements of individual Facility Effluent Monitoring Plans. This document is intended to be a basic road map to the Facility Effluent Monitoring Plan documents (i.e., the guidance document for preparing Facility Effluent Monitoring Plans, Facility Effluent Monitoring Plan determinations, management plan, and Facility Effluent Monitoring Plans). The implementing procedures, plans, and instructions are appropriate for the control of effluent monitoring plans requiring compliance with US Department of Energy, US Environmental Protection Agency, state, and local requirements. This Quality Assurance Project Plan contains a matrix of organizational responsibilities, procedural resources from facility or site manuals used in the Facility Effluent Monitoring Plans, and a list of the analytes of interest and analytical methods for each facility preparing a Facility Effluent Monitoring Plan. 44 refs., 1 figs., 2 tabs

  8. Impact of thermal discharge on marine environment - an overview

    International Nuclear Information System (INIS)

    Murugesan, A.G.; Rameshwari, S.; Sukumaran, N.

    2002-01-01

    Thermal pollution has been used to indicate the detrimental effects of heated effluents discharged by power plants and other industries. It denotes the impairment of quality and deterioration of aquatic and terrestrial environment through heated effluent and fly ash. Various industrial plants like thermal, atomic, nuclear, coal fired plants, oil field generators, factories and mills utilize water for cooling purposes. In India, there are about 60 thermal power plants, which produce 30 million tonnes of fly ash every year. The heated effluents from power plants is discharged at a temperature, which is 8-10 degC higher than that of intake marine water. The adverse effect of thermal discharge are visible in microorganism, fish, biotic life and the over all ecosystems. The discharge of heated effluents actually affects the fish respiration, metabolism and other physiological activities of marine organisms, which ultimately leads to death. This could be due to synergism because of toxic chemical such as copper, nickel, chromium and chlorine, which are used to remove slimes in the pipelines. The major waste material from thermal power station is the fly ash that creates enormous pollution problem to air, water and soil environment. Fly ash possess large amounts of lead, cobalt, chromium, cadmium etc. When this fly ash is released out through water carriage system it leads to turbidity, over deposition and flood also. Tuticorin Thermal Power Station (TTPS) has installed five power generation units each of 250 MW capacities. About 1.35 lakhs m 3 /hr water is drawn from the sea, utilized for cooling and then the heated effluent is discharged into the same environment. Therefore, this paper deals with various impacts associated with thermal discharge on marine environment. (author)

  9. Effects of volatile fatty acids in biohydrogen effluent on biohythane production from palm oil mill effluent under thermophilic condition

    Directory of Open Access Journals (Sweden)

    Chonticha Mamimin

    2017-09-01

    Conclusion: Preventing the high concentration of butyric acid, and propionic acid in the hydrogenic effluent could enhance methane production in two-stage anaerobic digestion for biohythane production.

  10. 40 CFR 415.112 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... SOURCE CATEGORY Potassium Metal Production Subcategory § 415.112 Effluent limitations guidelines... available (BPT): There shall be no discharge of process wastewater pollutants to navigable waters. ...

  11. 40 CFR 415.113 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... CATEGORY Potassium Metal Production Subcategory § 415.113 Effluent limitations guidelines representing the...): There shall be no discharge of process wastewater pollutants to navigable waters. ...

  12. Legal aspects of thermal discharges

    International Nuclear Information System (INIS)

    Martin, A.J.

    1974-01-01

    An overview of those legal areas which directly affect technical and planning decisions is presented in the form of 2 legal approaches which constrain the indiscriminate release of thermal discharges to receiving waters. One takes the form of private remedies which have traditionally been available to aggrieved parties who are in some way damaged by the harmful discharge. The 2nd approach utilizes the various statutory constraints leading to direct governmental action. It appears that statutory law is playing the prominent role in restricting the temperature to which receiving waters may be raised as a result of such discharges by using effluent limitations and water quality standards. (Water Resour. Abstr.)

  13. Impact of industrial effluents on surface waters

    International Nuclear Information System (INIS)

    Ahmed, K.

    2000-01-01

    The indiscriminate discharge of untreated municipal and industrial effluents has given rise to serious problems of water pollution and human health in Pakistan. The City of Lahore discharges about 365 mgd of wastewater with a BOD load of 250 tons per day, without treatment, into Ravi river. Because of the untreated industrial discharges, river Ravi is devoid of dissolved oxygen through most of its react between Lahore and Upper Chenab Canal under low flow conditions. Pollution levels can be controlled if each industry treats its own wastewater prior to disposal, in accordance with NEQS (Pakistan). (author)

  14. Assay of low-level plutonium effluents

    International Nuclear Information System (INIS)

    Hsue, S.T.; Hsue, F.; Bowersox, D.F.

    1981-01-01

    In the plutonium recovery section at the Los Alamos National Laboratory, an effluent solution is generated that contains low plutonium concentration and relatively high americium concentration. Nondestructive assay of this solution is demonstrated by measuring the passive L x-rays following alpha decay. Preliminary results indicate that an average deviation of 30% between L x-ray and alpha counting can be achieved for plutonium concentrations above 10 mg/L and Am/Pu ratios of up to 3; for plutonium concentrations less than 10 mg/L, the average deviation is 40%. The sensitivity of the L x-ray assay is approx. 1 mg Pu/L

  15. 40 CFR 401.12 - Law authorizing establishment of effluent limitations guidelines for existing sources, standards...

    Science.gov (United States)

    2010-07-01

    ... effluent limitations guidelines for existing sources, standards of performance for new sources and... ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS GENERAL PROVISIONS § 401.12 Law authorizing establishment of effluent limitations guidelines for existing sources, standards of performance...

  16. Activated sludge and activated carbon treatment of a wood preserving effluent containing pentachlorophenol

    National Research Council Canada - National Science Library

    Guo, P. H. M

    1980-01-01

    ...; however, PCP removal averaged only 35% and the effluent was toxic to rainbow trout. Treatment of the activated sludge effluent by carbon adsorption resulted in effective PCP removal and non-toxic effluents...

  17. Hydroponics reducing effluent's heavy metals discharge.

    Science.gov (United States)

    Rababah, Abdellah; Al-Shuha, Ahmad

    2009-01-01

    This paper investigates the capacity of Nutrient Film Technique (NFT) to control effluent's heavy metals discharge. A commercial hydroponic system was adapted to irrigate lettuces with primary treated wastewater for studying the potential heavy metals removal. A second commercial hydroponic system was used to irrigate the same type of lettuces with nutrient solution and this system was used as a control. Results showed that lettuces grew well when irrigated with primary treated effluent in the commercial hydroponic system. The NFT-plant system heavy metals removal efficiency varied amongst the different elements, The system's removal efficiency for Cr was more than 92%, Ni more than 85%, in addition to more than 60% reduction of B, Pb, and Zn. Nonetheless, the NFT-plants system removal efficiencies for As, Cd and Cu were lower than 30%. Results show that lettuces accumulated heavy metals in leaves at concentrations higher than the maximum acceptable European and Australian levels. Therefore, non-edible plants such as flowers or pyrethrum are recommended as value added crops for the proposed NFT.

  18. Sand filter clogging by septic tank effluent.

    Science.gov (United States)

    Spychała, M; Błazejewski, R

    2003-01-01

    The aim of this study was to characterise conditions and factors affecting fine sand clogging by septic tank effluent on the basis of physical modelling. The physical model consisted of 12 sand columns dosed with sewage from one household (5 persons), preliminary treated in a septic tank. Hydraulic loadings of the sand filters were equal to 82 mm/d. The mean discharge from sand columns, measured as the effluent volume collected during 10 minutes, decreased significantly over the experiment period from 34 cm3/min in August 2000 to 20 cm3/min in August 2001 at the same temperature of about 20 degrees C. First the columns clogged almost completely after 480 days in December 2001, however six columns had remained unclogged till the end of the experiment (March 2002). The temperature had a significant impact on hydraulic conductivity. A vertical distribution of accumulated mass and biomass was investigated in partly clogged sand. Microscopic survey of the clogging layer showed a presence of live micro-organisms, residuals of dead micro-organisms, particularly pieces of small animal armour and many fibres. These particles accelerated the accumulation of solids in the upper clogging layer. The study indicated that temperature impact on the filter hydraulic conductivity was more significant for biological activity, than for sewage viscosity.

  19. Airborne effluent control at uranium mills

    International Nuclear Information System (INIS)

    Sears, M.B.

    1976-01-01

    The Oak Ridge National Laboratory has made an engineering cost--environmental benefit study of radioactive waste treatment systems for decreasing the amount of radioactive materials released from uranium ore processing mills. This paper summarizes the results of the study which pertain to the control and/or abatement of airborne radioactive materials from the mill processes. The tailings area is not included. Present practices in the uranium milling industry, with particular emphasis on effluent control and waste management, have been surveyed. A questionnaire was distributed to each active mill in the United States. Replies were received from about 75 percent of the mill operators. Visits were made to six operating uranium mills that were selected because they represented the different processes in use today and the newest, most modern in mill designs. Discussions were held with members of the Region IV Office of NRC and the Grand Junction Office of ERDA. Nuclear Science Abstracts, as well as other sources, were searched for literature pertinent to uranium mill processes, effluent control, and waste management

  20. Processes influencing cooling of reactor effluents

    International Nuclear Information System (INIS)

    Magoulas, V.E.; Murphy, C.E. Jr.

    1982-01-01

    Discharge of heated reactor cooling water from SRP reactors to the Savannah River is through sections of stream channels into the Savannah River Swamp and from the swamp into the river. Significant cooling of the reactor effluents takes place in both the streams and swamp. The majority of the cooling is through processes taking place at the surface of the water. The major means of heat dissipation are convective transfer of heat to the air, latent heat transfer through evaporation and radiative transfer of infrared radiation. A model was developed which incorporates the effects of these processes on stream and swamp cooling of reactor effluents. The model was used to simulate the effect of modifications in the stream environment on the temperature of water flowing into the river. Environmental effects simulated were the effect of changing radiant heat load, the effect of changes in tree canopy density in the swamp, the effect of total removal of trees from the swamp, and the effect of diverting the heated water from L reactor from Steel Creek to Pen Branch. 6 references, 7 figures

  1. Effect of industrial effluents on the growth and anatomical structures ...

    African Journals Online (AJOL)

    The authors investigated the impact of industrial effluents from 5 different industrial concerns in Lagos, Nigeria on Okra (Abelmoschus esculentus). During the study, it was observed that these effluents induced detrimental effects on the flowering, fruiting, stem length, leaf width and leaf length of okra. Other parameters ...

  2. Tree production in desert regions using effluent and water harvesting

    Science.gov (United States)

    Martin M. Karpiscak; Gerald J. Gottfried

    2000-01-01

    Treated municipal effluent combined with water harvesting can be used for land restoration and enhancing the growth of important riparian tree species. Paired studies in Arizona are assessing the potential of growing trees using mixtures of effluent and potable water. Trees are grown in the field and in containers. Initial results from the field show high survival for...

  3. Treatment of radioactive effluents at the Boris Kidric Institute

    International Nuclear Information System (INIS)

    Bojovic, P.; Drobnik, S.; Popara, D.

    1964-10-01

    The paper describes the origin, composition and activity of radioactive effluents at the Boris Kidric Institute, their collection at the places or origin, transport to the place of disposal and treatment of some smaller quantities. Special attention has been paid to effluents with short-lived isotopes produced in the Laboratory for radioactive isotope production (author)

  4. Treatment of some Textile Industrial Effluents using Dry Corn Stalk ...

    African Journals Online (AJOL)

    Corn stalk ground to various mesh sizes was used to treat textile effluents obtained from three different industries. These effluents were first pretreated with alum and then charcoal; passing the water through a column, (20cm long and 5cm diameter) containing the ground corn stalk of size diameters of 300mm, 355mm ...

  5. Overexpression of antibiotic resistance genes in hospital effluents over time.

    Science.gov (United States)

    Rowe, Will P M; Baker-Austin, Craig; Verner-Jeffreys, David W; Ryan, Jim J; Micallef, Christianne; Maskell, Duncan J; Pearce, Gareth P

    2017-06-01

    Effluents contain a diverse abundance of antibiotic resistance genes that augment the resistome of receiving aquatic environments. However, uncertainty remains regarding their temporal persistence, transcription and response to anthropogenic factors, such as antibiotic usage. We present a spatiotemporal study within a river catchment (River Cam, UK) that aims to determine the contribution of antibiotic resistance gene-containing effluents originating from sites of varying antibiotic usage to the receiving environment. Gene abundance in effluents (municipal hospital and dairy farm) was compared against background samples of the receiving aquatic environment (i.e. the catchment source) to determine the resistome contribution of effluents. We used metagenomics and metatranscriptomics to correlate DNA and RNA abundance and identified differentially regulated gene transcripts. We found that mean antibiotic resistance gene and transcript abundances were correlated for both hospital ( ρ  = 0.9, two-tailed P  hospital effluent samples. High β-lactam resistance gene transcript abundance was related to hospital antibiotic usage over time and hospital effluents contained antibiotic residues. We conclude that effluents contribute high levels of antibiotic resistance genes to the aquatic environment; these genes are expressed at significant levels and are possibly related to the level of antibiotic usage at the effluent source. © The Author 2017. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy.

  6. Readiness Assessment Plan, Hanford 200 areas treated effluent disposal facilities

    International Nuclear Information System (INIS)

    Ulmer, F.J.

    1995-01-01

    This Readiness Assessment Plan documents Liquid Effluent Facilities review process used to establish the scope of review, documentation requirements, performance assessment, and plant readiness to begin operation of the Treated Effluent Disposal system in accordance with DOE-RLID-5480.31, Startup and Restart of Facilities Operational Readiness Review and Readiness Assessments

  7. Evaluation of some industrial effluents in Jos metropolis, Plateau ...

    African Journals Online (AJOL)

    Sometimes effluents gain access into wells or streams within the community. Analyses aimed to determine the strength of effluents of three different industries in Jos metropolis: industry A (a food industry), industry B (a pharmaceutical outfit) and Industry C (a water treatment plant) using parameters such as physicochemical, ...

  8. Facility effluent monitoring plan for 242-A evaporator facility

    International Nuclear Information System (INIS)

    Crummel, G.M.; Gustavson, R.D.

    1995-02-01

    A facility effluent monitoring plan is required by the U.S. Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could affect employee or public safety or the environment. A facility effluent monitoring plan determination was performed during Calendar Year 1991 and the evaluation showed the need for a facility effluent monitoring plan. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438-1. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated, as a minimum, every three years

  9. The chemical composition of the effluent from Awassa Textile ...

    African Journals Online (AJOL)

    The chemical composition of the effluent from the Awassa textile factory was quantified and its effects on chlorophyll-a concentration and fish fry were examined. The effluent contained high concentrations of toxic heavy metals, and concentrations of about 70% of all the elements measured were higher (by 10 to 100 times) ...

  10. Effluent treatment efficiency and compliance monitoring in Nigerian ...

    African Journals Online (AJOL)

    The effectiveness of effluent treatment at the Eleme Petrochemical Industry, Port Harcourt, Nigeria was monitored weekly for six weeks to assess their level of compliance with the Directorate of Petroleum Resources (DPR) guidelines and standards for environmental safety. Effluent samples were taken from the untreated ...

  11. 40 CFR 434.63 - Effluent limitations for precipitation events.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Effluent limitations for precipitation... SOURCE PERFORMANCE STANDARDS Miscellaneous Provisions § 434.63 Effluent limitations for precipitation... discharge or increase in the volume of a discharge caused by precipitation within any 24 hour period less...

  12. Operability test procedure for the TK-900 effluent monitoring station

    International Nuclear Information System (INIS)

    Weissenfels, R.D.

    1994-01-01

    This procedure will verify that the 221-B liquid effluent monitoring system, installed near the east end of the 6-in. chemical sewer header, functions as intended by design. TK-900B was installed near stairwell 3 in the 221-B electrical gallery by Project W-007H. The system is part of BAT/AKART for the BCE liquid effluent system

  13. Fungal protein from corn waste effluents : a model study

    NARCIS (Netherlands)

    Schellart, J.A.

    1975-01-01

    The purpose of this investigation was to study the microbiological aspects of the production of microbial protein ('single cell protein'; SCP) from corn waste effluents with simultaneous reduction of the COD of these effluents.

    For practical reasons the corn waste water itself was

  14. The Use of Kitchen Effluent as Alternative Nutrient Source for ...

    African Journals Online (AJOL)

    The recovery of oil based drilling muds was monitored for a period of 12 weeks upon inoculation with kitchen effluent. Oil based drilling muds inoculated with varying volumes (200ml, 250ml and 300ml) of kitchen effluent constituted the experimental set-ups, while the control set-ups were made up of oil based drilling muds ...

  15. Acute Toxicity Tests Of Brewery Effluent on the Ostracoda ...

    African Journals Online (AJOL)

    Mortality also varied with the concentrations. The toxic effect of brewery effluent on ostracoda, which plays an important role in the aquatic food chain and the possibility that they may be accumulating some of these toxic components, is a matter for concern. Keywords: Toxicity, rewery effluent, Ostracoda, Strandesia, ...

  16. Toxicity of cassava wastewater effluents to African catfish: Clarias ...

    African Journals Online (AJOL)

    The relative lethal and sublethal toxicity of cassava wastewater effluents from a local food factory were investigated on Clarias gariepinus fingerlings using a renewable static bioassay. The physico-chemical characteristics of the cassava wastewater effluents showed a number of deviations from the standards of the Federal ...

  17. A novel technique to monitor thermal discharges using thermal infrared imaging.

    Science.gov (United States)

    Muthulakshmi, A L; Natesan, Usha; Ferrer, Vincent A; Deepthi, K; Venugopalan, V P; Narasimhan, S V

    2013-09-01

    Coastal temperature is an important indicator of water quality, particularly in regions where delicate ecosystems sensitive to water temperature are present. Remote sensing methods are highly reliable for assessing the thermal dispersion. The plume dispersion from the thermal outfall of the nuclear power plant at Kalpakkam, on the southeast coast of India, was investigated from March to December 2011 using thermal infrared images along with field measurements. The absolute temperature as provided by the thermal infrared (TIR) images is used in the Arc GIS environment for generating a spatial pattern of the plume movement. Good correlation of the temperature measured by the TIR camera with the field data (r(2) = 0.89) make it a reliable method for the thermal monitoring of the power plant effluents. The study portrays that the remote sensing technique provides an effective means of monitoring the thermal distribution pattern in coastal waters.

  18. UV/H2O2 process performance improvement by ultrafiltration and physicochemical clarification systems for industrial effluent pretreatment

    Directory of Open Access Journals (Sweden)

    Ivanildo Hespanhol

    2012-12-01

    Full Text Available The present study evaluated the removal of TOC from an effluent with high organic load resulted from the treatment of oil-water emulsion by thermal process. Hollow Fiber Ultrafiltration membrane (HF-UF and physicochemical clarification process were used as pretreatment options to assess the influence of feed effluent quality on the UV/H2O2 oxidation process. Results for TOC removals showed HF-UF and physicochemical clarification processes can significantly improve the efficiency of UV/H2O2 oxidation process, when compared with the direct effluent oxidation. Reaction time for obtaining a TOC removal higher than 90% was reduced to approximately half of the time needed when no pretreatment was applied. Considering both pretreatment processes it was not possible to notice any significant difference on the UV/H2O2 oxidation process performance. However, the complexity of physicochemical process due to the use of three different chemicals and sludge production made the HF-UF process the best pretreatment alternative, without increasing the Total Dissolved Solids of the effluent, a very important issue when water reuse is considered.

  19. Design, calculation and testing on mock-up of B(U) f type LR 56 packaging for radioactive liquid effluent transport

    International Nuclear Information System (INIS)

    Belaud; Leconnetable; Daspet; Tombini; Tanguy

    1986-06-01

    Transport of radioactive acid liquid effluents are effected on tank truck inside nuclear center of the CEA. The cylindrical packaging type B(U) f has a capacity of 4,000l, a maximum permissible activity of 110 T Bq (3x10 4 Ci) and comprises a central element for liquid effluent containment to prevent contamination of environment and peripheral elements for mechanical, biological and thermal protection. This packaging is fixed on a trailer associated with a control box. Design and equipment of the packaging are studied for a maximum safety and in accordance with regulations [fr

  20. Asymptomatic Effluent Protozoa Colonization in Peritoneal Dialysis Patients.

    Science.gov (United States)

    Simões-Silva, Liliana; Correia, Inês; Barbosa, Joana; Santos-Araujo, Carla; Sousa, Maria João; Pestana, Manuel; Soares-Silva, Isabel; Sampaio-Maia, Benedita

    Currently, chronic kidney disease (CKD) is a global health problem. Considering the impaired immunity of CKD patients, the relevance of infection in peritoneal dialysis (PD), and the increased prevalence of parasites in CKD patients, protozoa colonization was evaluated in PD effluent from CKD patients undergoing PD. Overnight PD effluent was obtained from 49 asymptomatic stable PD patients. Protozoa analysis was performed microscopically by searching cysts and trophozoites in direct wet mount of PD effluent and after staining smears. Protozoa were found in PD effluent of 10.2% of evaluated PD patients, namely Blastocystis hominis, in 2 patients, and Entamoeba sp., Giardia sp., and Endolimax nana in the other 3 patients, respectively. None of these patients presented clinical signs or symptoms of peritonitis at the time of protozoa screening. Our results demonstrate that PD effluent may be susceptible to asymptomatic protozoa colonization. The clinical impact of this finding should be further investigated. Copyright © 2016 International Society for Peritoneal Dialysis.

  1. Radioactive effluent monitoring at the Idaho National Engineering Laboratory

    International Nuclear Information System (INIS)

    Simpson, O.D.

    1975-01-01

    The Effluent and Radiation Measurements Laboratory at the Idaho National Engineering Laboratory (INEL) has recently upgraded capabilities in the field of monitoring and analysis of radioactive airborne and liquid effluents using the techniques of gamma-ray spectrometry. The techniques and equipment used include remotely-operated, computer-based Ge(Li) spectrometers which obtain data on a real-time basis. Permanent record files are maintained of both the effluent release values and the gamma-ray data from which the release values are calculated. Should values for release levels ever be challenged, the gamma-ray spectral information for any measurement can be recalled and analyzed as needed. Daily effluent release reports are provided to operating personnel which contributes to prompt correction of any operational problems. Monthly, quarterly, and annual reports are compiled which provide inventories of the radionuclides released. A description of the effluent monitoring, reporting and records system developed at INEL for this application will be presented

  2. Facility Effluent Monitoring Plan for the Plutonium Finishing Plant

    International Nuclear Information System (INIS)

    FRAZIER, T.P.

    1999-01-01

    A facility effluent monitoring plan is required by the U. S. Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether these systems are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. To ensure the long-range integrity of the effluent monitoring systems, an update to this facility effluent monitoring plan is required whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document is reviewed annually even if there are no operational changes, and is updated, at a minimum, every 3 years

  3. Petroleum Refinery Effluents Treatment by Advanced Oxidation Process with Methanol

    Energy Technology Data Exchange (ETDEWEB)

    Shoucheng, Wen [Yangtze Univ., HuBei Jingzhou (China)

    2014-02-15

    Petroleum refinery effluents are waste originating from industries primarily engaged in refining crude oil. It is a very complex compound of various oily wastes, water, heavy metals and so on. Conventional processes are unable to effectively remove the chemical oxygen demand (COD) of petroleum refinery effluents. Supercritical water oxidation (SCWO) was proposed to treat petroleum refinery effluents. In this paper, methanol was used to investigate co-oxidative effect of methanol on petroleum refinery effluents treatment. The results indicated that supercritical water oxidation is an effective process for petroleum refinery effluents treatment. Adding methanol caused an increase in COD removal. When reaction temperature is 440 .deg. C, residence time is 20 min, OE is 0.5 and initial COD is 40000 mg/L, and COD removal increases 8.5%.

  4. Required ozone doses for removing pharmaceuticals from wastewater effluents

    DEFF Research Database (Denmark)

    Antoniou, Maria; Hey, Gerly; Rodríguez Vega, Sergio

    2013-01-01

    of each investigated API (DDO3) was determined for each effluent by fitting a first order equation to the remaining concentration of API at each applied ozone dose. Ozone dose requirements were found to vary significantly between effluents depending on their matrix characteristics.The specific ozone dose...... was then normalized to the dissolved organic carbon (DOC) of each effluent. The DDO3/DOC ratios were comparable for each API between the effluents.15 of the 42 investigated APIs could be classified as easily degradable (DDO3/DOC≤0.7), while 19 were moderately degradable (0.71.4). Furthermore, we predict...... that a reasonable estimate of the ozone dose required to remove any of the investigated APIs may be attained by multiplying the experimental average DDO3/DOC obtained with the actual DOC of any effluent....

  5. Petroleum Refinery Effluents Treatment by Advanced Oxidation Process with Methanol

    International Nuclear Information System (INIS)

    Shoucheng, Wen

    2014-01-01

    Petroleum refinery effluents are waste originating from industries primarily engaged in refining crude oil. It is a very complex compound of various oily wastes, water, heavy metals and so on. Conventional processes are unable to effectively remove the chemical oxygen demand (COD) of petroleum refinery effluents. Supercritical water oxidation (SCWO) was proposed to treat petroleum refinery effluents. In this paper, methanol was used to investigate co-oxidative effect of methanol on petroleum refinery effluents treatment. The results indicated that supercritical water oxidation is an effective process for petroleum refinery effluents treatment. Adding methanol caused an increase in COD removal. When reaction temperature is 440 .deg. C, residence time is 20 min, OE is 0.5 and initial COD is 40000 mg/L, and COD removal increases 8.5%

  6. Facility effluent monitoring plan for the tank farms facilities

    Energy Technology Data Exchange (ETDEWEB)

    Bachand, D.D.; Crummel, G.M.

    1995-05-01

    A facility effluent monitoring plan is required by the US Department of Energy for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using specific guidelines. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated as a minimum every three years.

  7. Performance analysis in stepped solar still for effluent desalination

    Energy Technology Data Exchange (ETDEWEB)

    Velmurugan, V. [Department of Mechanical Engineering, Infant Jesus College of Engineering, Thoothukudi, Tamil Nadu 628 851 (India); Naveen Kumar, K.J.; Noorul Haq, T.; Srithar, K. [Department of Mechanical Engineering, Thiagarajar College of Engineering, Madurai, Tamil Nadu 625 015 (India)

    2009-09-15

    In this work, a stepped solar still and an effluent settling tank are fabricated and tested for desalinating the textile effluent. The effluent is purified in an effluent settling tank. In this tank, large and fine solid particles are settled and clarified. The settled effluents are used as raw water in the stepped solar still. For better performance, the stepped solar still consists of 50 trays with two different depths. First 25 trays with 10 mm height and the next 25 trays with 5 mm height are used. Fin, sponge, pebble and combination of the above are used for enhancing the productivity of the stepped solar still. A maximum increase in productivity of 98% occurs in stepped solar still when fin, sponge and pebbles are used in this basin. Theoretical analysis agrees well with experimental results. (author)

  8. Liquid Effluent Monitoring Information System (LEMIS) System Construction

    International Nuclear Information System (INIS)

    Adams, R.T.

    1994-01-01

    The liquid effluent sampling program is part of the effort to minimize adverse environmental impact during the cleanup operation at the Hanford Site. Of the 33 Phase I and Phase II liquid effluents, all streams actively discharged to the soil column will be sampled. The Liquid Effluent Monitoring Information System (LEMIS) is being developed as the organized information repository facility in support of the liquid effluent monitoring requirements of the Tri-Party Agreement. It is necessary to provide an automated repository into which the results from liquid effluent sampling will be placed. This repository must provide for effective retention, review, and retrieval of selected sample data by authorized persons and organizations. This System Construction document is the aggregation of the DMR P+ methodology project management deliverables. Together they represent a description of the project and its plan through four Releases, corresponding to the definition and prioritization of requirements defined by the user

  9. Coal washery effluent treatment for material recovery and water reuse

    Energy Technology Data Exchange (ETDEWEB)

    Banerjee, N.N.; Chaudhuri, M.

    1980-10-01

    Th effluent from coal washeries consisting mainly of coal fines is normally discharged to inland surface waters and causes severe river pollution with substantial loss of good quality coking coal. The study reported in this paper was undertaken to characterize the effluents from several coal washeries and to evaluate the potential of using various coagulants and coagulant aids for clarification of the effluent with a view to recovery of the coal fines and reuse of the clarified effluent. It has been demonstrated that higher recovery of coal fines can be achieved by using coagulants like alum or ferric chloride with or without coagulant aids with an added advantage of reuse of the clarified effluent in the washery.

  10. Evaluation and verification of thermal stratification models for was

    African Journals Online (AJOL)

    USER

    prediction of the condition of thermal stratification in WSPs under different hydraulic conditions and ... off coefficient. The models are verified with data collected from the full scale waste .... comparing two mathematical models based ..... 2 Comparison of measured and predicted effluent coliform bacteria (N) againsty depth.

  11. Prospects for solving environmental problems pertinent to thermal power stations

    Energy Technology Data Exchange (ETDEWEB)

    A.G. Tumanovskii; V.R. Kotler [OAO All-Russia Thermal Engineering Institute, Moscow (Russian Federation)

    2007-06-15

    Possible ways to protect the atmosphere and water basin against harmful emissions and effluent waters discharged from thermal power stations are considered. Data on the effectiveness of different methods for removing NOx, SO{sub 2}, and ash particles, as well as heavy metals and CO{sub 2}, from these emissions and discharges are presented.

  12. Thermal effects on aquatic organisms: annotated bibliography of the 1974 literature

    International Nuclear Information System (INIS)

    Coutant, C.C.; Talmage, S.S.; Carrier, R.F.; Collier, B.N.

    1975-06-01

    The annotated bibliography covers the 1974 literature concerning thermal effects on aquatic organisms. Emphasis is placed on the effects of the release of thermal effluents on aquatic ecosystems. Indexes are provided for: author, keywords, subject category, geographic location, taxon, and title (alphabetical listing of keyword-in-context of the nontrivial words in the title). (CH)

  13. 40 CFR 424.13 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... representing the degree of effluent reduction attainable by the application of the best available technology economically achievable. 424.13 Section 424.13 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Furnaces With Wet Air Pollution Control Devices Subcategory § 424.13 Effluent limitations guidelines...

  14. 40 CFR 424.23 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... representing the degree of effluent reduction attainable by the application of the best available technology economically achievable. 424.23 Section 424.23 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Furnaces and Other Smelting Operations With Wet Air Pollution Control Devices Subcategory § 424.23 Effluent...

  15. 40 CFR 424.43 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... representing the degree of effluent reduction attainable by the application of the best available technology economically achievable. 424.43 Section 424.43 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Carbide Furnaces With Wet Air Pollution Control Devices Subcategory § 424.43 Effluent limitations...

  16. 40 CFR 458.43 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... this paragraph, which may be discharged from the carbon black lamp process by a point source subject to... Lamp Process Subcategory § 458.43 Effluent limitations guidelines representing the degree of effluent... achievable: There shall be no discharge of process waste water pollutants to navigable waters. ...

  17. 40 CFR 406.17 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... control technology. 406.17 Section 406.17 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 406.17 Effluent limitations guidelines representing the degree of effluent reduction attainable by the...] Effective Date Note: Section 406.17 was indefinitely suspended at 45 FR 45582, July 7, 1980. ...

  18. 40 CFR 406.27 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... control technology (BCT). 406.27 Section 406.27 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 406.27 Effluent limitations guidelines representing the degree of effluent reduction attainable by the... conventional pollutants (which are defined in § 401.16) in § 406.22 of this subpart for the best practicable...

  19. 40 CFR 406.47 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... control technology (BCT). 406.47 Section 406.47 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Subcategory § 406.47 Effluent limitations guidelines representing the degree of effluent reduction attainable... specified for conventional pollutants (which are defined in § 401.16) in § 406.42 of this subpart for the...

  20. 40 CFR 406.37 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... control technology (BCT). 406.37 Section 406.37 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Subcategory § 406.37 Effluent limitations guidelines representing the degree of effluent reduction attainable... specified for conventional pollutants (which are defined in § 401.16) in § 406.32 of this subpart for the...

  1. 40 CFR 417.163 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY Manufacture of Liquid Detergents Subcategory § 417.163 Effluent limitations guidelines representing the degree... subpart after application of the best available technology economically achievable: (a) For normal liquid...

  2. The effluent problem in a plutonium production centre; Probleme des effluents d'un centre de production de plutonium

    Energy Technology Data Exchange (ETDEWEB)

    Galley, R; Cantel, J [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    The first part of the report is devoted to generalities: the geographical situation of the Marcoule Centre, the sources of radio-active effluent, methods of treating this effluent. In the second part the authors gives a detailed description of the various installations in the Radio-active Effluent Treatment Station at the Marcoule Centre, and outline the conditions governing the rejection of treated effluent into the Rhone. A few lines are given to comparisons between the results obtained from the use of these installations up till may 1959 and the expected results published by the same authors at the Brussels Conference (1956). In conclusion the authors lay down some of the essential principles, applicable to the study of new installations. (author) [French] La premiere partie du rapport est consacree a quelques generalites: situation geographique du Centre de Marcoule, provenance des effluents radioactifs, methodes de traitement de ces effluents. Dans la seconde partie, les auteurs presentent une description detaillee des diverses installations de la Station de Traitement des Effluents radioactifs du Centre de Marcoule et precisent les conditions de rejet dans le Rhone des effluents radioactifs traites. Quelques lignes sont consacrees aux comparaisons entre les resultats de l'exploitation des installations jusqu'en mai 1959 et les previsions publiees par les memes auteurs a l'occasion de la Conference de Bruxelles (1956). En conclusion, les auteurs donnent quelques principes essentiels, applicables a l'etude de nouvelles installations. (auteur)

  3. 40 CFR 436.42 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... Industrial Sand Subcategory § 436.42 Effluent limitations guidelines representing the degree of effluent... 6.0 and water quality criteria in water quality standards approved under the Act authorize such lower pH, the pH limitation for such discharge may be adjusted downward to the pH water quality...

  4. 40 CFR 421.73 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... produced Lead .000 .000 Zinc .000 .000 (d) Subpart G—Dross Reverberatory Slag Granulation. BAT Effluent... per billion pounds) of slag, speiss, or matte granulated Lead 1,612.000 748.400 Zinc 5,872.000 2,418... produced Lead .000 .000 Zinc .000 .000 (g) Subpart G—Hard Lead Refining Slag Granulation. BAT Effluent...

  5. 40 CFR 429.163 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Science.gov (United States)

    2010-07-01

    ... degree of effluent reduction attainable by the application of the best available technology economically... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS TIMBER PRODUCTS PROCESSING POINT SOURCE CATEGORY Wood Furniture... application of the best available technology economically achievable (BAT). Except as provided in 40 CFR 125...

  6. 40 CFR 429.171 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Science.gov (United States)

    2010-07-01

    ... degree of effluent reduction attainable by the application of the best practicable control technology... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS TIMBER PRODUCTS PROCESSING POINT SOURCE CATEGORY Wood Furniture... best practicable control technology currently available (BPT). Except as provided in 40 CFR 125.30...

  7. 40 CFR 429.173 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Science.gov (United States)

    2010-07-01

    ... degree of effluent reduction attainable by the application of the best available technology economically... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS TIMBER PRODUCTS PROCESSING POINT SOURCE CATEGORY Wood Furniture... best available technology economically achievable (BAT). Except as provided in 40 CFR 125.30 through...

  8. 40 CFR 429.161 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Science.gov (United States)

    2010-07-01

    ... degree of effluent reduction attainable by the application of the best practicable control technology... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS TIMBER PRODUCTS PROCESSING POINT SOURCE CATEGORY Wood Furniture... application of the best practicable control technology currently available (BPT). Except as provided in 40 CFR...

  9. 40 CFR 417.153 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... operation of spray drying towers as defined above, the following values pertain: Effluent characteristic...) 1 Within the range 6.0 to 9.0. (b) For air quality restricted operation of a spray drying tower, but... Manufacture of Spray Dried Detergents Subcategory § 417.153 Effluent limitations guidelines representing the...

  10. 40 CFR 428.62 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Effluent limitations guidelines... technology currently available. 428.62 Section 428.62 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS RUBBER MANUFACTURING POINT SOURCE CATEGORY Medium...

  11. 40 CFR 428.63 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Effluent limitations guidelines... economically achievable. 428.63 Section 428.63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS RUBBER MANUFACTURING POINT SOURCE CATEGORY Medium-Sized General...

  12. 40 CFR 426.123 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS GLASS MANUFACTURING POINT SOURCE CATEGORY Incandescent Lamp... technology economically achievable: (a) [Reserved] (b) Any manufacturing plant which frosts incandescent lamp... characteristic Effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days shall...

  13. Removal of active species from liquid effluent

    International Nuclear Information System (INIS)

    Blake, N.J.; Ritchie, S.

    1992-01-01

    Experimental and theoretical assessments were made of recirculating liquid membrane technology applied to the removal of active species from liquid effluent. Caesium and strontium were extracted from neutral, aqueous liquor by di-(2-ethylhexyl) phosphate in odourless kerosine and subsequently stripped by nitric acid. Flowrates to the membrane modules influenced the extraction and stripping mass transfer coefficients (MTC) for caesium, but not strontium. The acid strength of the strip solution affected the stripping MTC. When both ions were co-processed, caesium transfer was retarded. Potassium cobalt ferrocyanide and polyantimonic acid were used as adsorbers for caesium and strontium respectively in the strip loop. Caesium was more quickly adsorbed than strontium. A scale-up assessment of a recirculating liquid membrane was performed and compared to SIXEP at Sellafield. (author)

  14. Separation of tritium from reprocessing effluents

    International Nuclear Information System (INIS)

    Bruggeman, A.; Doyen, W.; Harnie, R.; Leysen, R.; Meynendonckx, L.; Monsecour, M.; Goossens, W.R.A.; Baetsle, L.H.

    1980-01-01

    For several years tritium retention has been studied at the Belgian Nuclear Research Centre, SCK/CEN; initially attention was focused on the removal of tritium from gaseous reprocessing effluents. If tritium can be released from the spent fuel into the gaseous phase before any aqueous operation, adsorption on molecular sieves after some isotopic dilution with hydrogen and after complete conversion to (tritiated) water is the most practical collection method. A once-through 15 m 3 .h -1 oxidation-adsorption unit with a closed regeneration system and with a decontamination factor of 1000 at total (tritiated) hydrogen and water inlet concentrations down to 1000 vpm (parts per million by volume) has been constructed and tested at SCK/CEN and it is described in the text. If no special head-end treatment is used an appropriate liquid management inside the reprocessing plant restricts the volume of tritiated aqueous effluents to about 3 m 3 per tonne of LWR fuel processed. However, for further reduction an isotope separation process becomes necessary. SCK/CEN is developing the ELEX process, which is a combination of water ELectrolysis and tritium EXchange between hydrogen and water, the exchange being promoted by a hydrophobic catalyst. For electrolysis under normal conditions an elementary tritium separation factor of 11.6 with a standard deviation of 6% was obtained. As concerns the exchange step a hydrophobic catalyst has been developed which yields for the flow rates used at atmospheric pressure and at 20 0 C an overall exchange rate constant of 9 mol.s -1 .m -3 in a countercurrent trickle-bed reactor. At present an integrated bench scale de-tritiation unit is being built for further tests and for a dynamic demonstration of the ELEX process

  15. WASTE TREATMENT PLANT (WTP) LIQUID EFFLUENT TREATABILITY EVALUATION

    International Nuclear Information System (INIS)

    LUECK, K.J.

    2004-01-01

    A forecast of the radioactive, dangerous liquid effluents expected to be produced by the Waste Treatment Plant (WTP) was provided by Bechtel National, Inc. (BNI 2004). The forecast represents the liquid effluents generated from the processing of Tank Farm waste through the end-of-mission for the WTP. The WTP forecast is provided in the Appendices. The WTP liquid effluents will be stored, treated, and disposed of in the Liquid Effluent Retention Facility (LERF) and the Effluent Treatment Facility (ETF). Both facilities are located in the 200 East Area and are operated by Fluor Hanford, Inc. (FH) for the US. Department of Energy (DOE). The treatability of the WTP liquid effluents in the LERF/ETF was evaluated. The evaluation was conducted by comparing the forecast to the LERF/ETF treatability envelope (Aromi 1997), which provides information on the items which determine if a liquid effluent is acceptable for receipt and treatment at the LERF/ETF. The format of the evaluation corresponds directly to the outline of the treatability envelope document. Except where noted, the maximum annual average concentrations over the range of the 27 year forecast was evaluated against the treatability envelope. This is an acceptable approach because the volume capacity in the LERF Basin will equalize the minimum and maximum peaks. Background information on the LERF/ETF design basis is provided in the treatability envelope document

  16. Bioremediation of the textile waste effluent by Chlorella vulgaris

    Directory of Open Access Journals (Sweden)

    Hala Yassin El-Kassas

    2014-01-01

    Full Text Available The microalgae biomass production from textile waste effluent is a possible solution for the environmental impact generated by the effluent discharge into water sources. The potential application of Chlorella vulgaris for bioremediation of textile waste effluent (WE was investigated using 22 Central Composite Design (CCD. This work addresses the adaptation of the microalgae C. vulgaris in textile waste effluent (WE and the study of the best dilution of the WE for maximum biomass production and for the removal of colour and Chemical Oxygen Demand (COD by this microalga. The cultivation of C. vulgaris, presented maximum cellular concentrations Cmax and maximum specific growth rates μmax in the wastewater concentration of 5.0% and 17.5%, respectively. The highest colour and COD removals occurred with 17.5% of textile waste effluent. The results of C. vulgaris culture in the textile waste effluent demonstrated the possibility of using this microalga for the colour and COD removal and for biomass production. There was a significant negative relationship between textile waste effluent concentration and Cmax at 0.05 level of significance. However, sodium bicarbonate concentration did not significantly influence the responses of Cmax and the removal of colour and COD.

  17. Facility Effluent Monitoring Plan for the 222-S Laboratory

    International Nuclear Information System (INIS)

    Robinson, A.V.

    1991-11-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438. This facility effluent monitoring plan assesses effluent monitoring systems against applicable federal, state, and local requirements. This facility effluent monitoring plan is the first annual report. It shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. The current operation of the 222-S facilities includes the provision of analytical and radiological chemistry services in support of Hanford Site processing plants. The emphasis is on waste management, chemical processing, environmental monitoring effluent programs at B Plant, the Uranium Oxide Plant, Tank Farms, the 242-A Evaporator, the Waste Encapsulation and Storage Facility, the Plutonium-Uranium Extraction Facility, the Plutonium Finishing Plant, process development/impact activities, and essential materials. The laboratory also supplies analytical services in support of ongoing waste tank characterization

  18. Detoxification of kraft pulp ECF bleaching effluents by catalytic hydrotreatment.

    Science.gov (United States)

    Calvo, L; Gilarranz, M A; Casas, J A; Mohedano, A F; Rodríguez, J J

    2007-02-01

    Two different effluents from the D(1) and E(1) stages of the ECF bleaching of Eucalyptus globulus kraft pulp were treated by catalytic hydrogenation in a trickle bed reactor using commercial and homemade Pd/AC catalysts. The reactor was fed with the bleaching effluent and a H(2)/N(2) gas stream. The variables studied were space-time (1.4-5g(cat)min/mL), gas to liquid flow ratio (286-1000vol.), gas feed concentration (H(2):N(2), 1:1-1:7.3vol.), temperature (25-100 degrees C) and pressure (1-11bar). Hydrotreatment performance was evaluated in terms of ecotoxicity, adsorbable organic halogen (AOX), chemical oxygen demand (COD), biological oxygen demand (BOD(5)) and colour removal. In all the runs, the ecotoxicity of the effluents decreased as a result of the treatment, achieving reductions that ranged from 70% to 98%. Simultaneously to the reduction of toxicity, the hydrotreatment led to a decrease of the colour of the effluents, being the decrease significantly higher in the case of E(1) effluent. The AOX content was reduced by 85% and 23% for E(1) and D(1) effluents, respectively. In the case of D(1) effluent the removal of ecotoxicity was significantly higher than that of AOX, which indicates that much of the toxicity of the effluent must be associated to non-chlorinated organics. In spite of the important reduction of ecotoxicity, the biodegradability of the effluents only increased slightly. The homemade catalysts, prepared from activated carbons with a high external or non-microporous surface area and mesopore volume and a convenient surface chemistry showed a higher efficiency than the commercial one.

  19. Facility Effluent Monitoring Plan for the N Reactor

    International Nuclear Information System (INIS)

    Watson, D.J.; Brendel, D.F.; Shields, K.D.

    1991-11-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP- 0438. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan is the first annual report. It shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated as a minimum every three years. The primary purpose of the N Reactor Facility Effluent Monitoring Plan (FEMP), during standby, is to ensure that the radioactive effluents are properly monitored and evaluated for compliance with the applicable DOE orders and regulatory agencies at the federal, state, and local levels. A secondary purpose of the FEMP is to ensure that hazardous wastes are not released, in liquid effluents, to the environment even though the potential to do so is extremely low. The FEMP is to provide a monitoring system that collects representative samples in accordance with industry standards, performs analyses within stringent quality control (QC) requirements, and evaluates the data through the use of comparative analysis with the standards and acceptable environmental models

  20. Fast microbial reduction of ferrihydrite colloids from a soil effluent

    Science.gov (United States)

    Fritzsche, Andreas; Bosch, Julian; Rennert, Thilo; Heister, Katja; Braunschweig, Juliane; Meckenstock, Rainer U.; Totsche, Kai U.

    2012-01-01

    Recent studies on the microbial reduction of synthetic iron oxide colloids showed their superior electron accepting property in comparison to bulk iron oxides. However, natural colloidal iron oxides differ in composition from their synthetic counterparts. Besides a potential effect of colloid size, microbial iron reduction may be accelerated by electron-shuttling dissolved organic matter (DOM) as well as slowed down by inhibitors such as arsenic. We examined the microbial reduction of OM- and arsenic-containing ferrihydrite colloids. Four effluent fractions were collected from a soil column experiment run under water-saturated conditions. Ferrihydrite colloids precipitated from the soil effluent and exhibited stable hydrodynamic diameters ranging from 281 (±146) nm in the effluent fraction that was collected first and 100 (±43) nm in a subsequently obtained effluent fraction. Aliquots of these oxic effluent fractions were added to anoxic low salt medium containing diluted suspensions of Geobacter sulfurreducens. Independent of the initial colloid size, the soil effluent ferrihydrite colloids were quickly and completely reduced. The rates of Fe2+ formation ranged between 1.9 and 3.3 fmol h-1 cell-1, and are in the range of or slightly exceeding previously reported rates of synthetic ferrihydrite colloids (1.3 fmol h-1 cell-1), but greatly exceeding previously known rates of macroaggregate-ferrihydrite reduction (0.07 fmol h-1 cell-1). The inhibition of microbial Fe(III) reduction by arsenic is unlikely or overridden by the concurrent enhancement induced by soil effluent DOM. These organic species may have increased the already high intrinsic reducibility of colloidal ferrihydrite owing to quinone-mediated electron shuttling. Additionally, OM, which is structurally associated with the soil effluent ferrihydrite colloids, may also contribute to the higher reactivity due to increasing solubility and specific surface area of ferrihydrite. In conclusion, ferrihydrite

  1. Management of radioactive effluents from research Reactors and PHWRs

    International Nuclear Information System (INIS)

    Bodke, S.B.; Surender Kumar; Sinha, P.K.; Budhwar, R.K.; Raj, Kanwar

    2006-01-01

    Indian nuclear power programme is mainly based on pressurized heavy water reactors (PHWRs). In addition we have research reactors namely Apsara, CIRUS, Dhruva at Trombay. The operation and maintenance activities of these reactors generate radioactive liquid waste. These wastes require effective management so that the release of radioactivity to the environment is well within the authorized limits. India is self reliant in the design, erection, commissioning and operation of effluent management system for nuclear reactors. Segregation at source based on nature of effluents and radioactivity content is the first and foremost step in the over all management of liquid effluents. The effluents from the power reactors contain mainly activation products like 3 H. It also contains fission products like 137 Cs. Containment of these radionuclide along with 60 Co, 90 Sr, 131 I plays an important part in liquid waste management. Treatment processes for decontamination of these radionuclide include chemical treatment, ion exchange, evaporation etc. Effluents after treatment are monitored and discharged to the nearby water body after filtration and dilution. The concentrates from the processes are conditioned in cement matrix and disposed in Near Surface Disposal Facilities (NSDFs) co-located at each site. Some times large quantity of effluents with higher radioactivity concentration may get generated from the abnormal operation such as failure of heat exchangers. These effluents are handled on a campaign basis for which adequate storage capacity is provided. The treatment is given taking into consideration the required decontamination factor (DF), capacities of available treatment process, discharge limits and the availability of the dilution water. Similarly large quantities of effluents may get generated during fuel clad failure incident in reactors. In such situation, as in CIRUS large volume of effluent containing higher radioactivity are generated and are managed by delay

  2. 200 Area TEDF effluent sampling and analysis plan

    International Nuclear Information System (INIS)

    Alaconis, W.C.; Ballantyne, N.A.; Boom, R.J.

    1995-06-01

    This sampling analysis sets forth the effluent sampling requirements, analytical methods, statistical analyses, and reporting requirements to satisfy the State Waste Discharge Permit No. ST4502 for the Treated Effluent Disposal Facility. These requirements are listed below: Determine the variability in the effluent of all constituents for which enforcement limits, early warning values and monitoring requirements; demonstrate compliance with the permit; and verify that BAT/AKART (Best Available Technology/All know and Reasonable Treatment) source, treatment, and technology controls are being met

  3. Guide for effluent radiological measurements at DOE installations

    International Nuclear Information System (INIS)

    Corley, J.P.; Corbit, C.D.

    1983-07-01

    Effluent monitoring and reporting programs are maintained at all US Department of Energy (DOE) facilities that may: (1) discharge significant concentrations of radioactivity in relation to applicable standards, or (2) discharge quantities of radioactivity that have potential health and safety or other environmental significance. This Guide is intended to provide supplemental guidance to DOE Orders on methods, procedures, and performance criteria to bring more comparable rationale to DOE facility effluent measurement programs and promote compliance with applicable standards and provide the DOE Office of Operational Safety (OOS) and Operations Offices with an additional tool for evaluating effluent measurement programs at DOE facilities

  4. Utilization of vinasse effluents from an anaerobic reactor

    Energy Technology Data Exchange (ETDEWEB)

    Costa, F J.C.B.; Rocha, B B.M.; Viana, C E; Toledo, A C

    1986-01-01

    An anaerobic reactor was developed to biodigest alcohol distillery wastes. A further post-treatment of the effluent reduced the level of pollution to the point of eventually discharging into streams and rivers. The present work also analyses the use of biodigested vinasse as a source of food for fish. Very high efficiencies were obtained during primary and secondary treatment of vinasse effluent, as demonstrated by the greatly reduced organic load. The utilization of the treated effluent as a source of fish food presents an excellent alternative for the Brazilian alcohol industry. (Refs. 6).

  5. Effluent generation by the dairy industry: preventive attitudes and opportunities

    Directory of Open Access Journals (Sweden)

    V. B. Brião

    2007-12-01

    Full Text Available Work aimed to identify the effluent is generating areas in a dairy company for purpose of changing concept pollution prevention. methodology consisted measuring volumes and collecting samples effluents production sectors. analysis was conducted by sector, order those which generated excessive amounts effluents. results show that dry products (powdered milk powdered whey are greatest generators BOD, nitrogen phosphorus, while fluid form (UHT milk, formulated UHT, pasteurized cream butter produced large quantities oils grease. solids recovery, waste segregation water reuse can be applied with saving potential as much R$ 28,000 ($ 11,200 per month only raw materials also environmental gains in pollution prevention.

  6. Facility effluent monitoring plan for the 327 Facility

    International Nuclear Information System (INIS)

    1994-11-01

    The 327 Facility [Post-Irradiation Testing Laboratory] provides office and laboratory space for Pacific Northwest Laboratory (PNL) scientific and engineering staff conducting multidisciplinary research in the areas of post-irradiated fuels and structural materials. The facility is designed to accommodate the use of radioactive and hazardous materials in the conduct of these activities. This report summarizes the airborne emissions and liquid effluents and the results of the Facility Effluent Monitoring Plan (FEMP) determination for the facility. The complete monitoring plan includes characterization of effluent streams, monitoring/sampling design criteria, a description of the monitoring systems and sample analysis, and quality assurance requirements

  7. Radioactive clearance discharge of effluent from nuclear and radiation facilities

    International Nuclear Information System (INIS)

    Liu Xinhua; Xu Chunyan

    2013-01-01

    On the basis of the basic concepts of radiation safety management system exemption, exclusion and clearance, we expound that the general industrial gaseous and liquid effluent discharges are exempted or excluded, gaseous and liquid effluent discharged from nuclear and radiation facilities are clearance, and non-radioactive. The main purpose of this paper is to clarify the concepts, reach a consensus that the gaseous and liquid effluent discharged from nuclear and radiation facilities are non-radioactive and have no hazard to human health and natural environment. (authors)

  8. (EFB)-palm oil mill effluent

    African Journals Online (AJOL)

    Jane

    2011-06-15

    Jun 15, 2011 ... decomposed by a combination of physical, chemical and biological processes. ... shade and cement base area. Brick blocks with length of ..... Elemental compositions, FT-IR spectra and thermal behavior of sedimentary fulvic ...

  9. Thermal comfort

    CSIR Research Space (South Africa)

    Osburn, L

    2010-01-01

    Full Text Available Thermal comfort is influenced by environmental parameters as well as other influences including asymmetric heating and cooling conditions. Additionally, some aspects of thermal comfort may be exploited so as to enable a building to operate within a...

  10. 40 CFR 141.551 - What strengthened combined filter effluent turbidity limits must my system meet?

    Science.gov (United States)

    2010-07-01

    ... effluent turbidity limits must my system meet? 141.551 Section 141.551 Protection of Environment... Effluent Requirements § 141.551 What strengthened combined filter effluent turbidity limits must my system meet? Your system must meet two strengthened combined filter effluent turbidity limits. (a) The first...

  11. PFOS and PFOA in influents, effluents, and biosolids of Chinese wastewater treatment plants and effluent-receiving marine environments

    International Nuclear Information System (INIS)

    Chen Hong; Zhang Can; Han Jianbo; Yu Yixuan; Zhang Peng

    2012-01-01

    Concentrations of perfluorooctane sulfonate (PFOS) and perfluorooctanoate (PFOA) in influents, effluents and sludges were investigated by analyzing the samples from twelve wastewater treatment plants (WWTPs) in China. The highest concentrations of PFOS and PFOA in influents were found to occur in municipal and industrial WWTPs, respectively. Relative to PFOS and PFOA concentrations in influents, elevated concentrations were observed in effluents from WWTPs applying anaerobic–anoxic–oxic wastewater treatment process. Importantly, application of previously reported organic carbon normalized partition coefficients (K OC ) derived from sediment-based sorption experiments appear to underestimate the PFOS and PFOA levels in biosolids quantified in the current study. PFOS and PFOA levels in effluents were found to be approximately 27 and 2 times higher than those detected in the effluent-receiving seawater, respectively. However, their levels in this area of seawater haven't exceeded the provisional short-term health advisories in drinking water issued by U.S. EPA yet. - Highlights: ► Levels of PFOS and PFOA in influents, effluents and sludge from Chinese WWTPs were examined. ► Municipal sewage was the main source for PFOS in Chinese WWTPs, while industrial sewage for PFOA. ► PFOS and PFOA concentrations in effluents were much higher than those in receiving seawater. - Levels of PFOS and PFOA in influent, effluent and sludge samples from Chinese WWTPs were examined and found much higher than those in receiving seawater.

  12. Use of calcined layered double hydroxides for the removal of color and organic matter from textile effluents: kinetic, equilibrium and recycling studies

    Directory of Open Access Journals (Sweden)

    T. P. F. Teixeira

    2014-03-01

    Full Text Available This paper presents data for the synthesis and characterization of layer double hydroxides (LDH and their use for color and chemical oxygen demand (COD removal from effluents generated by a textile industry. Adsorption studies with raw and biologically treated (activated sludge textile effluent showed that the pseudo-second order model best fitted the experimental data, leading to adsorption coefficients of 39.1 and 102.9 mgCOD/gLDH for raw and treated effluents, respectively. The best conditions for color and COD removal were obtained at lower values of temperature and pH (25 °C and pH 7 and, in these conditions, an LDH dose of 10 g/L resulted in color removal efficiencies of 56% for samples of raw and 66% for samples of treated effluent. Recycling studies indicated that the reuse of thermally treated LDH led to a progressive loss in the removal efficiencies of COD and color. The reduction was more pronounced with samples of the raw textile effluent. LDH characterization performed before and after each adsorption and regeneration experiment showed that there was no intercalation of dye molecules in the interlayer region of the LDH, indicating that COD and color removal might be due to the adsorption of organic molecules onto the LDH surface.

  13. Effluent Information System (EIS) / Onsite Discharge Information System (ODIS): 1986 executive summary

    International Nuclear Information System (INIS)

    Watanabe, T.

    1987-09-01

    Department of Energy (DOE) data base systems aid DOE-Headquarters and Field Offices in managing the radioactive air and liquid effluents from DOE facilities. Data on effluents released offsite are entered into effluent information system (EIS) and data on effluents discharged onsite and retained onsite are entered into Onsite Discharge Information System (ODIS). This document is a summary of information obtained from the CY 1986 effluent data received from all DOE and DOE contractor facilities and entered in the data bases. Data from previous years are also included. The summary consists of information for effluents released offsite, and information for effluents retained onsite

  14. Mathematical analysis of brewery effluent distribution in Ikpoba ...

    African Journals Online (AJOL)

    Samples of waste water and river water which were taken at predetermined points, ... thereby making the research result relevant for surface water pollution control. Keywords: Brewery effluent, pollutants, lotic ecosystem, water pollution, river, ...

  15. Effects of Cassava Mill Effluent on Some Chemical and Micro ...

    African Journals Online (AJOL)

    user

    KEY WORDS: Cassava Mill Effluent, Soil Pollution, Soil Properties, Bacteria, Fungi. INTRODUCTION .... The hydrocarbon utilizing bacteria (HUB) were Bacillus substilis and ..... fermentative hydrogen production: A Review Int. J. Hydrogen ...

  16. Correlating Biochemical and Chemical Oxygen Demand of Effluents

    African Journals Online (AJOL)

    F. K. Attiogbe1, Mary Glover-Amengor2 and K. T. Nyadziehe3

    There is also a slaughterhouse for animals (Sarfo-Afriyie, 1999). ... day period of the BOD test, the bacteria oxidized mainly the soluble organic ..... characteristics of the waste (effluent) not being constant (http://www.hach.com), and this is.

  17. Computed tomography in diagnostics of effluent otitis media

    International Nuclear Information System (INIS)

    Imomova, L.S.; Norboev, Z.; Kalandarov, S.Ch.

    2011-01-01

    This article is devoted to computed tomography in diagnostics of effluent otitis media. The purpose of present work is to assess the possibilities of computed tomography method of temporal bone in the diagnostics of otitis media.

  18. Assessment of the effect of effluent discharge from coffee refineries ...

    African Journals Online (AJOL)

    Admin

    2Department of Environmental Health, Jimma University, Jimma, Ethiopia. ... cherries, transport them hydraulically through the pulping ..... Table 2. Interaction effects of effluent discharges by coffee refineries on physical characteristics between.

  19. Analysis of tannery effluents from the Challawa industrial estate in ...

    African Journals Online (AJOL)

    Global Journal of Pure and Applied Sciences ... and some physicochemical parameters such as conductivity, solids, chloride, chromium, alkalinity, sulphide, chemical oxygen demand, COD, and biochemical oxygen demand, BOD, of the waste water were determined. ... Keywords: tannery, effluent, pollution, environment

  20. Bioremediation of textile effluent polluted soil using kenaf (Hibiscus ...

    African Journals Online (AJOL)

    DR BADA

    Bioremediation of textile effluent polluted soil using kenaf (Hibiscus cannabinus Linn.) and composted ... Lead, Cadmium, Chromium and Zinc levels in plants and soil were determined using Atomic ..... Contaminated land in the EC: Report of ...

  1. physico-chemical characteristics of effluents from garri processing

    African Journals Online (AJOL)

    DR. AMIN

    0.62ppm all in contrast to World Health Organization maximum admissible limit of 0.07ppm. A two- ... indiscriminate discharge of industrial effluents [Salami and Egwin, 1997]. ..... Wastewater Engineering, Treatment and Refuse,. 4th edition ...

  2. Biodegradation Potentials of Cassava Mill Effluent (CME) by ...

    African Journals Online (AJOL)

    ADOWIE PERE

    ABSTRACT: The indiscriminate discharge of Cassava mill effluent pose serious ... The study has shown that microbial isolates have the potentials of reducing pollution effect thereby ..... villages in Portharcourt, Rivers State Nigeria. J. Appl. Sci.

  3. Electrochemical Corrosion Investigations on Anaerobic Treated Distillery Effluent

    Science.gov (United States)

    Ram, Chhotu; Sharma, Chhaya; Singh, A. K.

    2014-09-01

    Present study is focused on the corrosivity of anaerobic treated distillery effluent and corrosion performance of mild steel and stainless steels. Accordingly, electrochemical polarization tests were performed in both treated distillery and synthetic effluents. Polarization tests were also performed in synthetic solutions and it was observed that Cl- and K+ increase whereas SO4 -, PO4 -, NO3 -, and NO2 - decrease the corrosivity of effluent at alkaline pH. Further, comparison in corrosivity of distillery and synthetic effluents shows the former to be less corrosive and this is assigned due to the presence of amino acids and melanoidins. Mild steel experienced to have the highest corrosion rate followed by stainless steels—304L and 316L and lowest in case of SAF 2205. Relative corrosion resistance of stainless steels is observed to depend upon Cr, Mo, and N content.

  4. The effluent problem in a plutonium production centre

    International Nuclear Information System (INIS)

    Galley, R.; Cantel, J.

    1960-01-01

    The first part of the report is devoted to generalities: the geographical situation of the Marcoule Centre, the sources of radio-active effluent, methods of treating this effluent. In the second part the authors gives a detailed description of the various installations in the Radio-active Effluent Treatment Station at the Marcoule Centre, and outline the conditions governing the rejection of treated effluent into the Rhone. A few lines are given to comparisons between the results obtained from the use of these installations up till may 1959 and the expected results published by the same authors at the Brussels Conference (1956). In conclusion the authors lay down some of the essential principles, applicable to the study of new installations. (author) [fr

  5. Limits to radioactive effluents and countermeasures in accidental situations

    International Nuclear Information System (INIS)

    Nowotny, G.; Gonzalez, A.

    1978-01-01

    The paper discusses the criteria used by the Argentine Atomic Energy Commission, as competent authority, to set limits to radioactive effluents from nuclear installations. It also discusses the selection of action levels for carrying out countermeasures in accidental situations. (author)

  6. Diffusion characteristics of the Kakinada Bay for effluent assessment

    Digital Repository Service at National Institute of Oceanography (India)

    Unnikrishnan, A.S.; Asthana, V.

    The present study reports the determination of diffusion characteristics of the Kakinada Bay to choose a suitable marine outfall location for industrial discharge of effluents from a proposed fertilizer plant. The study consisted of dye diffusion...

  7. Radiation-adsorption purification of effluents containing pesticides

    International Nuclear Information System (INIS)

    Brusentseva, S.A.; Shubin, V.N.; Nikonorova, G.K.; Zorin, D.M.; Sosnovskaya, A.A.; Petryaev, E.P.; Vlasova, V.I.; Edimicheva, I.P.; Subbotina, N.N.; Belorusskij Gosudarstvennyj Univ., Minsk)

    1986-01-01

    The radiation-adsorption purification is one of the new direction in the radiation purification of natural wastes and effluents containing pesticides. This method combines the conventional adsorption purification with radiation treatment of the sorbent, and the result the protection time of the sorbent increases due to the radiation regeneration of carbon. In present work the method was used for purification of effluents from pesticides, such as 4,4'Dichlorodiphenyltrichloroethane /DDT/, 1,2,3,4,5,6-hexachlorocyclohexane /HCCH/, dimethyl 2,2-dichlorovinylphosphate /DDVF/ and petroleum products (a mixture of kerosene and xylene in ratio 7:1). Such effluents are formed at factories producing an insecticide aerosol 'Prime-71'. Three investigations were carried out on model with a solution similar composition to industrial effluents. (author)

  8. Performance evaluation of effluent treatment plant for automobile industry

    Energy Technology Data Exchange (ETDEWEB)

    Ansari, Farid [Department of Applied Science and Humanities, PDM College of Engineering, Bahadurgarh (Haryana) (India); Pandey, Yashwant K. [School of Energy and Environmental Studies, Devi Ahilya Vishwavidyalaya, Indore (India); Kumar, P.; Pandey, Priyanka [Department of Environmental Science, Post Graduate College Ghazipur (IN

    2013-07-01

    The automobile industry’s wastewater not only contains high levels of suspended and total solids such as oil, grease, dyestuff, chromium, phosphate in washing products, and coloring, at various stages of manufacturing but also, a significant amount of dissolved organics, resulting in high BOD or COD loads. The study reveals the performance, evaluation and operational aspects of effluent treatment plant and its treatability, rather than the contamination status of the real property. The Results revealed that the treated effluent shows most of the parameters are within permissible limits of Central Pollution Control Board (CPCB), India and based on the site visits, discussion with operation peoples, evaluation of process design, treatment system, existing effluent discharge, results of sample analyzed and found that effluent treatment plant of automobile industry are under performance satisfactory.

  9. Assessment of wastewater treatment plant effluent effects on fish reproduction

    Science.gov (United States)

    Wastewater treatment plant (WWTP) effluents are known contributors of chemical mixtures into the environment. Of particular concern are endocrine-disrupting compounds that can affect hypothalamic-pituitary-gonadal axis function in exposed organisms. The present study examined t...

  10. 200 Area treated effluent disposal facility operational test report

    International Nuclear Information System (INIS)

    Crane, A.F.

    1995-01-01

    This document reports the results of the 200 Area Treated Effluent Disposal Facility (200 Area TEDF) operational testing activities. These completed operational testing activities demonstrated the functional, operational and design requirements of the 200 Area TEDF have been met

  11. Bioremediation of textile effluent polluted soil using kenaf ( Hibiscus ...

    African Journals Online (AJOL)

    Bioremediation of textile effluent polluted soil using kenaf ( Hibiscus cannabinus Linn.) and composted ... Journal of Applied Sciences and Environmental Management. Journal Home ... Twelve-litre plastic pots were filled with 10 kg soil.

  12. Removal of pharmaceuticals in WWTP effluents by ozone and ...

    African Journals Online (AJOL)

    2013-02-12

    Feb 12, 2013 ... discharge of effluents by wastewater treatment plants (WWTPs) that are not ... The efficiency of ozone in removing pharmaceuticals and personal care ...... assessment and modeling of an ozonation step for full-scale munic-.

  13. Concentrations of heavy metals in effluent discharges downstream ...

    African Journals Online (AJOL)

    ONOS

    2010-01-18

    Jan 18, 2010 ... nickel, lead and zinc) in the effluents and receiving water were analyzed by atomic absorption ... forms in which metal pollutants exist in waste water dis- charges ..... Enforcement held in Oazaca, Mexico, April 25-28, 1995.

  14. Bioremediation of chromium in tannery effluent by microbial consortia

    African Journals Online (AJOL)

    USER

    2010-05-24

    May 24, 2010 ... Chromium is the most toxic and common among the heavy metal pollutants of industrial effluents .... Chromium (Cleseari and Green, 1995) included the oxidation of .... like uranium in its cells might also match with its tendency.

  15. Feasibility of using geothermal effluents for waterfowl wetlands

    Energy Technology Data Exchange (ETDEWEB)

    None

    1981-09-01

    This project was conducted to evaluate the feasibility of using geothermal effluents for developing and maintaining waterfowl wetlands. Information in the document pertains to a seven State area the West where geothermal resources have development potential. Information is included on physiochemical characteristics of geothermal effluents; known effects of constituents in the water on a wetland ecosystem and water quality criteria for maintaining a viable wetland; potential of sites for wetland development and disposal of effluent water from geothermal facilities; methods of disposal of effluents, including advantages of each method and associated costs; legal and institutional constraints which could affect geothermal wetland development; potential problems associated with depletion of geothermal resources and subsidence of wetland areas; potential interference (adverse and beneficial) of wetlands with ground water; special considerations for wetlands requirements including size, flows, and potential water usage; and final conclusions and recommendations for suitable sites for developing demonstration wetlands.

  16. Impact of upstream industrial effluents on irrigation water quality ...

    African Journals Online (AJOL)

    Impact of upstream industrial effluents on irrigation water quality, soils and ... Knowledge of irrigation water quality is critical to predicting, managing and reducing salt ... Presence of heavy metals in concentration higher than the recommended ...

  17. 300 Area Treated Effluent Disposal Facility (TEDF) Hazards Assessment

    International Nuclear Information System (INIS)

    CAMPBELL, L.R.

    1999-01-01

    This document establishes the technical basis in support of emergency planning activities for the 300 Area Treated Effluent Disposal Facility. The technical basis for project-specific Emergency Action Levels and Emergency Planning Zone is demonstrated

  18. Interpretation of the concepts of ALARA and bat for radioactive effluent releases from nuclear installation

    International Nuclear Information System (INIS)

    Chen Xiaoqiu

    2009-01-01

    Based on the understanding of the important concepts of both ALARA and BAT associated with the characteristics of effluent releases from the existing nuclear installations and the abatement techniques for effluents, this paper elaborates the principle of controlling radioactive effluent concentration from nuclear installation, that is based on the BAT focusing on the abatement techniques for effluents, introduces the good practice in the projects, and optimize the effluent releases with account taken of external factors such as the site condition. (authors)

  19. An automation model of Effluent Treatment Plant

    Directory of Open Access Journals (Sweden)

    Luiz Alberto Oliveira Lima Roque

    2012-07-01

    Full Text Available Population growth and intensification of industrial activities have increased the deterioration of natural resources. Industrial, hospital and residential wastes are dumped directly into landfills without processing, polluting soils. This action will have consequences later, because the liquid substance resulting from the putrefaction of organic material plows into the soil to reach water bodies. Cities arise without planning, industrial and household wastes are discharged into rivers, lakes and oceans without proper treatment, affecting water resources. It is well known that in the next century there will be fierce competition for fresh water on the planet, probably due to the scarcity of it. Demographic expansion has occurred without proper health planning, degrading oceans, lakes and rivers. Thus, a large percentage of world population suffers from diseases related to water pollution. Accordingly, it can be concluded that sewage treatment is essential to human survival, to preserve rivers, lakes and oceans. An Effluent Treatment Plant (ETP treats wastewater to reduce its pollution to acceptable levels before sending them to the oceans or rivers. To automate the operation of an ETP, motors, sensors and logic blocks, timers and counters are needed. These functions are achieved with programmable logic controllers (PLC and Supervisory Systems. The Ladder language is used to program controllers and is a pillar of the Automation and Control Engineering. The supervisory systems allow process information to be monitored, while the PLC are responsible for control and data acquisition. In the age we live in, process automation is used in an increasing scale in order to provide higher quality, raise productivity and improve the proposed activities. Therefore, an automatic ETP will improve performance and efficiency to handle large volumes of sewage. Considering the growing importance of environmental awareness with special emphasis

  20. Thief carbon catalyst for oxidation of mercury in effluent stream

    Science.gov (United States)

    Granite, Evan J [Wexford, PA; Pennline, Henry W [Bethel Park, PA

    2011-12-06

    A catalyst for the oxidation of heavy metal contaminants, especially mercury (Hg), in an effluent stream is presented. The catalyst facilitates removal of mercury through the oxidation of elemental Hg into mercury (II) moieties. The active component of the catalyst is partially combusted coal, or "Thief" carbon, which can be pre-treated with a halogen. An untreated Thief carbon catalyst can be self-promoting in the presence of an effluent gas streams entrained with a halogen.

  1. Overexpression of antibiotic resistance genes in hospital effluents over time

    OpenAIRE

    Rowe, Will P. M.; Baker-Austin, Craig; Verner-Jeffreys, David W.; Ryan, Jim J.; Micallef, Christianne; Maskell, Duncan J.; Pearce, Gareth P.

    2017-01-01

    $\\textbf{Objectives}$: Effluents contain a diverse abundance of antibiotic resistance genes that augment the resistome of receiving aquatic environments. However, uncertainty remains regarding their temporal persistence, transcription and response to anthropogenic factors, such as antibiotic usage. We present a spatiotemporal study within a river catchment (River Cam, UK) that aims to determine the contribution of antibiotic resistance gene-containing effluents originating from sites of varyi...

  2. Liquid effluent Sampling and Analysis Plan (SAP) implementation summary report

    International Nuclear Information System (INIS)

    Lueck, K.J.

    1995-01-01

    This report summarizes liquid effluent analytical data collected during the Sampling and Analysis Plan (SAP) Implementation Program, evaluates whether or not the sampling performed meets the requirements of the individual SAPs, compares the results to the WAC 173-200 Ground Water Quality Standards. Presented in the report are results from liquid effluent samples collected (1992-1994) from 18 of the 22 streams identified in the Consent Order (No. DE 91NM-177) requiring SAPs

  3. British Nuclear Fuels plc's effluent plant services building

    International Nuclear Information System (INIS)

    Williams, L.

    1990-01-01

    The new Effluent Plant Services building (EPSB) on the Sellafield Nine Acre Site was built by Costain Engineering Limited for British Nuclear Fuels Limited. The EPSB is dedicated to a new generation of nuclear waste treatment plants, aimed at reducing discharges into the Irish Sea and other environmental impacts by removing actinides from liquid effluents and decontaminating waste solvents. This article describes the design, construction and operation of the plant. (UK)

  4. Method of removing iodine and compounds thereof from gaseous effluents

    International Nuclear Information System (INIS)

    Keener, R.L.; Kittle, P.A.

    1976-01-01

    Anion exchange resins including an acrylic backbone formed by the suspension polymerization of a mixture of an acrylic and a crosslinking monomer are useful in the removal of iodine and iodine compounds from gaseous effluents. Removal of radioactive iodine contaminants, particularly alkyl iodine compounds or hydrogen iodine, under extreme conditions, namely temperatures up to 180 0 C and humidities up to 100 percent, from effluents resulting from a major nuclear accident could probably be adsorbed by these resins described herein

  5. 300 Area Treated Effluent Disposal Facility permit reopener run plan

    International Nuclear Information System (INIS)

    Olander, A.R.

    1995-01-01

    The 300 Area Treated Effluent Disposal Facility (TEDF) is authorized to discharge treated effluent to the Columbia River by National Pollutant Discharge Elimination System permit WA-002591-7. The letter accompanying the final permit noted the following: EPA recognizes that the TEDF is a new waste treatment facility for which full scale operation and effluent data has not been generated. The permit being issued by EPA contains discharge limits that are intended to force DOE's treatment technology to the limit of its capability.'' Because of the excessively tight limits the permit contains a reopener clause which may allow limits to be renegotiated after at least one year of operation. The restrictions for reopening the permit are as follows: (1) The permittee has properly operated and maintained the TEDF for a sufficient period to stabilize treatment plant operations, but has nevertheless been unable to achieve the limitation specified in the permit. (2) Effluent data submitted by the permittee supports the effluent limitation modifications(s). (3) The permittee has submitted a formal request for the effluent limitation modification(s) to the Director. The purpose of this document is to guide plant operations for approximately one year to ensure appropriate data is collected for reopener negotiations

  6. Evaporation behaviour of different organic effluents from open surfaces.

    Science.gov (United States)

    Jhorar, B S; Malik, R S

    1993-01-01

    Production of large quantities of effluents from different industrial units and the problems of their disposal necessitated this evaporation study. The evaporation of water, sewage water, oil refinery effluent, papermill effluent and liquor distillery effluent was observed in glass beakers when placed (i) in an oven at 60 degrees C and (ii) in screen house for 30 days, by periodically weighing of the beakers. In other experiments, the effect of increasing the frequency of stirring on increasing the evaporation efficiency of the liquor distillery effluent (ELD) was examined in detail. All of the organic effluents except ELD had similar evaporation behaviours as water, but formation of a self-forming film caused the evaporation of ELD to be considerably lower. Resistance to evaporation caused by this film was found to be a decreasing function of the frequency of stirring. This study has a bearing on improving the efficiency of evaporation lagoons, and three stirrings in a day with a manually drawn stirrer in a full-scale lagoon are proposed as a practical and economically viable technique to save 44% of lagoon land in arid and semi-arid regions of the world.

  7. Efficiency of aquatic macrophytes to treat Nile tilapia pond effluents

    Directory of Open Access Journals (Sweden)

    Henry-Silva Gustavo Gonzaga

    2006-01-01

    Full Text Available The effluents from fish farming can increase the quantity of suspended solids and promote the enrichment of nitrogen and phosphorus in aquatic ecosystems. In this context, the aim of this work was to evaluate the efficiency of three species of floating aquatic macrophytes (Eichhornia crassipes, Pistia stratiotes and Salvinia molesta to treat effluents from Nile tilapia culture ponds. The effluent originated from a 1,000-m² pond stocked with 2,000 male Nile tilapia Oreochromis niloticus. The treatment systems consisted of 12 experimental tanks, three tanks for each macrophyte species, and three control tanks (without plants. Water samples were collected from the: (i fish pond source water, (ii effluent from fish pond and (iii effluents from the treatment tanks. The following water variables were evaluated: turbidity, total and dissolved nitrogen, ammoniacal-N, nitrate-N, nitrite-N, total phosphorus and dissolved phosphorus. E. crassipes and P. stratiotes were more efficient in total phosphorus removal (82.0% and 83.3%, respectively and total nitrogen removal (46.1% and 43.9%, respectively than the S. molesta (72.1% total phosphorus and 42.7% total nitrogen and the control (50.3% total phosphorus and 22.8% total nitrogen, indicating that the treated effluents may be reused in the aquaculture activity.

  8. Radioactive and electron microscope analysis of effluent monitor sample lines

    International Nuclear Information System (INIS)

    Kowalski, J.F.

    1986-01-01

    Effluent air sampling at nuclear power plant often leads to the question ''How representative is the sample of the effluent stream?'' Samples from radiation monitors are typically obtained at great distances from the sample nozzle because of high background concerns under postulated accidents. Sample line plateout during normal effluent sampling becomes the major concern. A US Nuclear Regulatory Commission inspection raised a concern that monitors were not collecting representative samples per ANSI standard N13.1. A comprehensive 2-yr study at Beaver Valley was performed during normal effluent releases in two phases: 1) weekly charcoal and glass fiber filter samples were analyzed for radioactivity for 6 months, and 2) nuclepore membrane filter samples were analyzed by electron microscope for 4- and 6-h periods. A specially designed test nozzle was directly inserted into an effluent stream for comparison with the radiation monitor samples. Particle behavior characteristics can be determined during effluent releases using a simple test probe. While particle plateout was the major purpose of the study, other particle behavior characteristics were evident and equally as important. Particle travel through long sample lines can also lead to (a) agglomeration or the coagulation of smaller particles to form larger ones, (b) particle splitting or fracturing upon impact with the sample line interior walls, and (c) resuspension of large particles in sample lines

  9. Microalgal Cultivation in Secondary Effluent: Recent Developments and Future Work

    Directory of Open Access Journals (Sweden)

    Junping Lv

    2017-01-01

    Full Text Available Eutrophication of water catchments and the greenhouse effect are major challenges in developing the global economy in the near future. Secondary effluents, containing high amounts of nitrogen and phosphorus, need further treatment before being discharged into receiving water bodies. At the same time, new environmentally friendly energy sources need to be developed. Integrating microalgal cultivation for the production of biodiesel feedstock with the treatment of secondary effluent is one way of addressing both issues. This article provides a comprehensive review of the latest progress in microalgal cultivation in secondary effluent to remove pollutants and accumulate lipids. Researchers have discovered that microalgae remove nitrogen and phosphorus effectively from secondary effluent, accumulating biomass and lipids in the process. Immobilization of appropriate microalgae, and establishing a consortium of microalgae and/or bacteria, were both found to be feasible ways to enhance pollutant removal and lipid production. Demonstrations of pilot-scale microalgal cultures in secondary effluent have also taken place. However there is still much work to be done in improving pollutants removal, biomass production, and lipid accumulation in secondary effluent. This includes screening microalgae, constructing the consortium, making use of flue gas and nitrogen, developing technologies related to microalgal harvesting, and using lipid-extracted algal residues (LEA.

  10. 40 CFR 468.16 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Science.gov (United States)

    2010-07-01

    ... degree of effluent reduction attainable by the application of the best conventional pollution control technology (BCT). [Reserved] 468.16 Section 468.16 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... application of the best conventional pollution control technology (BCT). [Reserved] ...

  11. 40 CFR 458.42 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... Carbon Black Lamp Process Subcategory § 458.42 Effluent limitations guidelines representing the degree of... shall be no discharge of process waste water pollutants into navigable waters. [60 FR 33972, June 29...

  12. 40 CFR 418.73 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... economically achievable. 418.73 Section 418.73 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Fertilizer Production Subcategory § 418.73 Effluent limitations guidelines representing the degree of...

  13. 40 CFR 417.73 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... economically achievable. 417.73 Section 417.73 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Manufacture of Bar Soaps Subcategory § 417.73 Effluent limitations guidelines representing the degree of...

  14. Detritiation of Tritiated Effluent Gas and Water

    International Nuclear Information System (INIS)

    Ahn, Do Hee; Kim, Kwang Rag; Paek, Seung Woo; Lee, Min Soo; Yim, Sung Paal; Chung Hong Suk

    2007-06-01

    In a demonstration scale equipment for treatment of tritium in off-gas, Pt/SDBC as oxidation catalyst and Zeolite 13X as adsorbent was charged in the beds, respectively. It was confirmed from the performance test that decontamination factor of the equipment showed more than 100 under the flow rate of off-gas of 90 l/hr and at the temperature of 65 ∼ 80 .deg. C. A small scale CECE process has been developed combining LPCE catalytic column with SPE (solid polymer electrolyte) electrolysis. The catalytic column was a trickle-bed type packed with the mixture of 1 wt% Pt/SDBC catalyst and 4 mm Dixon wire-mesh ring. The experimental results of the CECE process proved that the decontamination factor of 13 ∼ 20 under the operating conditions of the water of the 4 l/day and the effluent hydrogen gas of 16.2 mol/h. A design code of CECE process also developed which will be applied the tritium industry. An experimental method for the reduction of tritiated organic waste by using catalytic oxidation was tested in a heated catalytic reactor of 0.5 wt% Pd/Al 2 O 3 . The simulated organic liquid was converted to water over 99%. A gas chromatographic column material was developed for the separation of mixed hydrogen isotopes. 17 wt% Pd-Pt on alumina showed 90% separation efficiency at 77 % yield for the separation of 29.2 % D 2 -H 2 gas mixture

  15. Soil aquifer treatment using advanced primary effluent

    KAUST Repository

    Sharma, Saroj K.; Hussen, Mustefa; Amy, Gary L.

    2011-01-01

    Soil aquifer treatment (SAT) using primary effluent (PE) is an attractive option for wastewater treatment and reuse in many developing countries with no or minimal wastewater treatment. One of the main limitations of SAT of PE is rapid clogging of the infiltration basin due to high suspended solid concentrations. Some pre-treatment of PE before infiltration is likely to reduce this limitation, improve performance of SAT and help to implement this technology effectively. The effects of three pre-treatment options namely sedimentation (SED), coagulation (COAG) and horizontal roughing filtration (HRF) on SAT were analyzed by conducting laboratory-scale batch and soil column experiments. The sedimentation and coagulation pre-treatments led to less head loss development and reduction of clogging effect. The head loss development in soil column using PE + COAG and PE + SED was reduced by 85 and 72%, respectively, compared to PE alone without any pretreatment. The overall dissolved organic carbon (DOC) removal of pre-treatments and soil column collectively were 34, 44, 51 and 43.5% for PE without any pre-treatment, PE + SED, PE+ COAG and PE + HRF, respectively. Coagulation pre-treatment of PE was found to be the most effective option in terms of suspended solids, DOC and nitrogen removal. Sedimentation pre-treatment of PE could be attractive where land is relatively less expensive for the construction of sedimentation basins. © IWA Publishing 2011.

  16. Soil aquifer treatment using advanced primary effluent

    KAUST Repository

    Sharma, Saroj K.

    2011-08-01

    Soil aquifer treatment (SAT) using primary effluent (PE) is an attractive option for wastewater treatment and reuse in many developing countries with no or minimal wastewater treatment. One of the main limitations of SAT of PE is rapid clogging of the infiltration basin due to high suspended solid concentrations. Some pre-treatment of PE before infiltration is likely to reduce this limitation, improve performance of SAT and help to implement this technology effectively. The effects of three pre-treatment options namely sedimentation (SED), coagulation (COAG) and horizontal roughing filtration (HRF) on SAT were analyzed by conducting laboratory-scale batch and soil column experiments. The sedimentation and coagulation pre-treatments led to less head loss development and reduction of clogging effect. The head loss development in soil column using PE + COAG and PE + SED was reduced by 85 and 72%, respectively, compared to PE alone without any pretreatment. The overall dissolved organic carbon (DOC) removal of pre-treatments and soil column collectively were 34, 44, 51 and 43.5% for PE without any pre-treatment, PE + SED, PE+ COAG and PE + HRF, respectively. Coagulation pre-treatment of PE was found to be the most effective option in terms of suspended solids, DOC and nitrogen removal. Sedimentation pre-treatment of PE could be attractive where land is relatively less expensive for the construction of sedimentation basins. © IWA Publishing 2011.

  17. Studies on osmotic concentration of radioactive effluents

    International Nuclear Information System (INIS)

    Thomas, K.C.; Ramachandhran, V.; Misra, B.M.

    1986-01-01

    The potential of direct osmosis for concentrating radioactive effluents is examined on the laboratory scale. Studies were carried out using asymmetric cellulose acetate membranes of a range of porosities under varying salinity gradients. A suitable bench scale osmotic concentrator employing tubular membrane systems has been fabricated and tested. An attempt to understand the mechanism of water permeation under osmotic and hydrostatic gradients has been made based on the irreversible thermodynamic approach. The solute separation of sodium chloride and radionuclides under osmosis is in the range of 85 to 95% for various osmotic sink solutions. The osmotic water flux is observed to be lower than the hydraulic water flux under reverse osmosis conditions. While the solute separation increases with an increase in annealing temperature, water flux decreases for both osmosis and reverse osmosis systems for various feed salinities. The effect of concentration polarization is analysed, and the effect of feed and osmotic sink velocity on the performance of the osmotic concentrator has also been studied. (orig.)

  18. EFFLUENT TREATMENT FACILITY PEROXIDE DESTRUCTION CATALYST TESTING

    International Nuclear Information System (INIS)

    HALGREN DL

    2008-01-01

    The 200 Area Effluent Treatment Facility (ETF) main treatment train includes the peroxide destruction module (PDM) where the hydrogen peroxide residual from the upstream ultraviolet light/hydrogen peroxide oxidation unit is destroyed. Removal of the residual peroxide is necessary to protect downstream membranes from the strong oxidizer. The main component of the PDM is two reaction vessels utilizing granular activated carbon (GAC) as the reaction media. The PDM experienced a number of operability problems, including frequent plugging, and has not been utilized since the ETF changed to groundwater as the predominant feed. The unit seemed to be underperforming in regards to peroxide removal during the early periods of operation as well. It is anticipated that a functional PDM will be required for wastewater from the vitrification plant and other future streams. An alternate media or methodology needs to be identified to replace the GAC in the PDMs. This series of bench scale tests is to develop information to support an engineering study on the options for replacement of the existing GAC method for peroxide destruction at the ETF. A number of different catalysts will be compared as well as other potential methods such as strong reducing agents. The testing should lead to general conclusions on the viability of different catalysts and identify candidates for further study and evaluation

  19. 40 CFR 418.32 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... solution product: Effluent characteristics Effluent limitations (mg/l) Maximum for any 1 day Average of...) 0.61 0.33 Note: Metric units: Kilogram/1,000 kg of product; English units: Pound/1,000 lb of product....18 0.59 Organic nitrogen (as N) 1.48 0.80 Note: Metric units: Kilogram/1,000 kg of product; English...

  20. Thermal insulation

    International Nuclear Information System (INIS)

    Aspden, G.J.; Howard, R.S.

    1988-01-01

    The patent concerns high temperature thermal insulation of large vessels, such as the primary vessel of a liquid metal cooled nuclear reactor. The thermal insulation consists of multilayered thermal insulation modules, and each module comprises a number of metal sheet layers sandwiched between a back and front plate. The layers are linked together by straps and clips to control the thickness of the module. (U.K.)

  1. Treatment of Effluent from a Factory of Paints Using Solar Photo-Fenton Process

    Directory of Open Access Journals (Sweden)

    Alam Gustavo Trovó

    2013-01-01

    Full Text Available We evaluated the use of Fenton reactions induced by solar radiation in the treatment of effluent from a factory of paints for buildings, after prior removal of the suspended solids. The increase of H2O2 concentration from 100 to 2500 mg L−1 for a [Fe2+] = 105 mg L−1 contributed to the reduction of DOC, COD, and toxicity. Our best results were achieved using 1600 mg L−1 H2O2, with 90% of DOC and COD removal and a complete removal of the toxicity with respect to Artemia salina. Additionally, through increasing Fe2+ concentration from 15 to 45 mg L−1, the DOC removal rate increased 11 times, remaining almost constant in the range above 45 until 105 mg L−1. Under our best experimental conditions, 80% of DOC removal was achieved after an accumulated dose of 130 kJ m−2 of UVA radiation (82±17 min of solar irradiation under an average UVA irradiance of 34.1±7.3 W m−2, while 40% of DOC removal was reached after 150 min under only thermal Fenton reactions. The results suggest the effectiveness of implementation of solar photo-Fenton process in the decontamination and detoxification of effluents from factories of paints for buildings.

  2. Detritiation of Tritiated Effluent Gas and Water

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Do Hee; Kim, Kwang Rag; Paek, Seung Woo; Lee, Min Soo; Yim, Sung Paal; Chung Hong Suk

    2007-06-15

    In a demonstration scale equipment for treatment of tritium in off-gas, Pt/SDBC as oxidation catalyst and Zeolite 13X as adsorbent was charged in the beds, respectively. It was confirmed from the performance test that decontamination factor of the equipment showed more than 100 under the flow rate of off-gas of 90 l/hr and at the temperature of 65 {approx} 80 .deg. C. A small scale CECE process has been developed combining LPCE catalytic column with SPE (solid polymer electrolyte) electrolysis. The catalytic column was a trickle-bed type packed with the mixture of 1 wt% Pt/SDBC catalyst and 4 mm Dixon wire-mesh ring. The experimental results of the CECE process proved that the decontamination factor of 13 {approx} 20 under the operating conditions of the water of the 4 l/day and the effluent hydrogen gas of 16.2 mol/h. A design code of CECE process also developed which will be applied the tritium industry. An experimental method for the reduction of tritiated organic waste by using catalytic oxidation was tested in a heated catalytic reactor of 0.5 wt% Pd/Al{sub 2}O{sub 3}. The simulated organic liquid was converted to water over 99%. A gas chromatographic column material was developed for the separation of mixed hydrogen isotopes. 17 wt% Pd-Pt on alumina showed 90% separation efficiency at 77 % yield for the separation of 29.2 % D{sub 2}-H{sub 2} gas mixture.

  3. High Speed/ Low Effluent Process for Ethanol

    Energy Technology Data Exchange (ETDEWEB)

    M. Clark Dale

    2006-10-30

    n this project, BPI demonstrated a new ethanol fermentation technology, termed the High Speed/ Low Effluent (HS/LE) process on both lab and large pilot scale as it would apply to wet mill and/or dry mill corn ethanol production. The HS/LE process allows very rapid fermentations, with 18 to 22% sugar syrups converted to 9 to 11% ethanol ‘beers’ in 6 to 12 hours using either a ‘consecutive batch’ or ‘continuous cascade’ implementation. This represents a 5 to 8X increase in fermentation speeds over conventional 72 hour batch fermentations which are the norm in the fuel ethanol industry today. The ‘consecutive batch’ technology was demonstrated on a large pilot scale (4,800 L) in a dry mill corn ethanol plant near Cedar Rapids, IA (Xethanol Biofuels). The pilot demonstrated that 12 hour fermentations can be accomplished on an industrial scale in a non-sterile industrial environment. Other objectives met in this project included development of a Low Energy (LE) Distillation process which reduces the energy requirements for distillation from about 14,000 BTU/gal steam ($0.126/gal with natural gas @ $9.00 MCF) to as low as 0.40 KW/gal electrical requirements ($0.022/gal with electricity @ $0.055/KWH). BPI also worked on the development of processes that would allow application of the HS/LE fermentation process to dry mill ethanol plants. A High-Value Corn ethanol plant concept was developed to produce 1) corn germ/oil, 2) corn bran, 3) ethanol, 4) zein protein, and 5) nutritional protein, giving multiple higher value products from the incoming corn stream.

  4. Ichthyofauna community from Saco de Piraquara de Fora area by the influence of liquid effluents from the Almirante Alvaro Alberto Nuclear Power in Angra dos Reis

    International Nuclear Information System (INIS)

    Almeida, A.F.V. de

    1995-01-01

    To verify if thermal and chemical effluents of Angra I Nuclear Power Plant are affecting the marine ictiofauna, Furnas Centrais Eletricas S.A. has implemented a monitoring program near the discharge area. Specific composition, frequency, specific relative abundance, specific diversity and others parameters are studied. The main target of this study is to check if the analyzed parametrers show any kind of impact on fish population. In this paper the results were presented. (author). 7 refs, 3 figs, 3 tabs

  5. Integrated membrane and microbial fuel cell technologies for enabling energy-efficient effluent Re-use in power plants.

    Science.gov (United States)

    Shrestha, Namita; Chilkoor, Govinda; Xia, Lichao; Alvarado, Catalina; Kilduff, James E; Keating, John J; Belfort, Georges; Gadhamshetty, Venkataramana

    2017-06-15

    Municipal wastewater is an attractive alternative to freshwater sources to meet the cooling water needs of thermal power plants. Here we offer an energy-efficient integrated microbial fuel cell (MFC)/ultrafiltration (UF) process to purify primary clarifier effluent from a municipal wastewater treatment plant for use as cooling water. The microbial fuel cell was shown to significantly reduce chemical oxygen demand (COD) in the primary settled wastewater effluent upstream of the UF module, while eliminating the energy demand required to deliver dissolved oxygen in conventional aerobic treatment. We investigated surface modification of the UF membranes to control fouling. Two promising hydrophilic monomers were identified in a high-throughput search: zwitterion (2-(Methacryloyloxy)-ethyl-dimethyl-(3-sulfopropyl ammoniumhydroxide, abbreviated BET SO 3 - ), and amine (2-(Methacryloyloxy) ethyl trimethylammonium chloride, abbreviated N(CH 3 ) 3 + ). Monomers were grafted using UV-induced polymerization on commercial poly (ether sulfone) membranes. Filtration of MFC effluent by membranes modified with BET SO 3 - and N(CH 3 ) 3 + exhibited a lower rate of resistance increase and lower energy consumption than the commercially available membrane. The MFC/UF process produced high quality cooling water that meets the Electrical Power Research Institute (EPRI) recommendations for COD, a suite of metals (Fe, Al, Cu, Zn, Si, Mn, S, Ca and Mg), and offered extremely low corrosion rates (<0.05 mm/yr). A series of AC and DC diagnostic tests were used to evaluate the MFC performance. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Thermal insulation

    International Nuclear Information System (INIS)

    Pinsky, G.P.

    1977-01-01

    Thermal insulation for vessels and piping within the reactor containment area of nuclear power plants is disclosed. The thermal insulation of this invention can be readily removed and replaced from the vessels and piping for inservice inspection, can withstand repeated wettings and dryings, and can resist high temperatures for long periods of time. 4 claims, 3 figures

  7. Remote sensing analysis of thermal plumes at the Savannah River Plant

    International Nuclear Information System (INIS)

    Doak, E.L.

    1985-01-01

    The nuclear reactors of the Savannah River Plant (SRP) in Aiken, South Carolina, use cold water diverted from the Savannah River to dissipate unused thermal energy. This water is heated by heat exchangers of the reactors during the materials production process, and then returned to the natural drainage system. Thermal effluents were monitored by an airborne thermal infrared scanner during predawn overlights. Images were generated to show the surface temperature distribution of the thermal outfall plumes into the Savannah River. The thermal analysis provides information related to compliance with permit requirements of the regulatory agencies

  8. Determining the Effects of Various Factors on the Effectiveness of Ultrasonic Treatment of Secondary Effluent

    Directory of Open Access Journals (Sweden)

    Sakineh Haddadi

    2007-09-01

    Full Text Available Sonochemical degradation which combines destruction of the target compounds by free radical reaction and thermal cleavage is a recent advanced oxidation process (AOP with the potential to be effective for removing low concentrations of organic pollutants from aqueous streams. AOPs typically involve the generation and use of the hydroxyl free radical as a strong oxidant to destroy compounds. The decomposition rate of pollutants by ultrasound depends on various factors. In this study, the effects of pH, initial concentration, hydrogen peroxide addition, and TSS concentration on the decomposition of organics in the secondary effluent have been investigated. COD analysis was taken as the index for organic concentration and two ultrasonic frequencies of 35 kHz and 130 kHz were used for treatment of wastewater samples. Results indicated that increases in organic concentration within the range of 20-60 mg/L would decrease organic removal efficiency from wastewater (p

  9. Application of inorganic ion exchangers for low and medium activity radioactive effluent decontamination

    International Nuclear Information System (INIS)

    Dozol, J.F.; Eymard, S.; Gambade, R.; La Rosa, G.

    1986-01-01

    This study proposes an alternative pretreatment or treatment for low and medium activity liquid wastes, allowing to improve the quality of containment and decrease the cost of storage. Inorganic ion exchangers are used to remove alpha emitters and long lived fission products and concentrate them in a small volume; these exchangers can be converted into a stable matrix by thermal treatment. This treatment, at least for some liquid wastes, don't exclude a complementary decontamination by chemical precipitation. Sludges, arising from precipitation, exempt from alpha emitters and long lived fission products can be stored in a shallow land burial. This study includes two parts: - Measurements of distribution coefficients for the main nuclides in order to choose, for each liquid wastes, the most suitable ion exchanger. - Estimation of performances of selected inorganic ion exchangers, from tests of percolation of genuine effluents

  10. Effects of thermal pollution on marine life

    International Nuclear Information System (INIS)

    Peres, J.M.

    1976-01-01

    After a short review of the conditions and importance of the releases of heated water from fossil- or nuclear- fueled power plants, the two-fold consequences of thermal pollution are stated: consequences from the transit damaging, by thermal stress and/or mechanical effects, planctonic organisms attracted in the stream, and consequences from heating of the receiving environment. Other related effect on marine populations should not be neglected: effects of antifouling (chlorine mostly) and anticorrosion products; synergic action of raised temperature and chemical pollutants. In the present state of knowledge, the hazards of thermal pollution in the marine environment should not be overestimated so far as effluent dilution and diffusion are sufficient, which implies that the site be selected in an area where coastal circulation is strong enough and the disposal procedures be improved [fr

  11. Tannery Effluent Treatment by Yeast Species Isolates from Watermelon

    Directory of Open Access Journals (Sweden)

    Stanley Irobekhian Reuben Okoduwa

    2017-02-01

    Full Text Available The quest for an effective alternative means for effluent treatment is a major concern of the modern-day scientist. Fungi have been attracting a growing interest for the biological treatment of industrial wastewater. In this study, Saccharomycescerevisiae and Torulasporadelbrueckii were isolated from spoiled watermelon and inoculated into different concentrations of effluent. The inoculants were incubated for 21-days to monitor the performance of the isolates by measurement of biochemical oxygen demand (BOD, chemical oxygen demand (COD, nitrates, conductivity, phosphates, sulphates and turbidity. The results showed that Saccharomycescerevisiae had the highest percentage decrease of 98.1%, 83.0%, 60.7%, 60.5%, and 54.2% for turbidity, sulphates, BOD, phosphates and COD, respectively, of the tannery effluent. Torulasporadelbrueckii showed the highest percentage decrease of 92.9%, 90.6%, and 61.9% for sulphates, COD, and phosphates, respectively, while the syndicate showed the highest percentage reduction of 87.4% and 70.2% for nitrate and total dissolve solid (TDS, respectively. The least percentage decrease was displayed by syndicate organisms at 51.2%, 48.1% and 40.3% for BOD, COD and conductivity, respectively. The study revealed that Saccharomycescerevisiae and Torulasporadelbrueckii could be used in the biological treatment of tannery-effluent. Hence, it was concluded that the use of these organisms could contribute to minimizing the adverse environmental risks and health-hazards associated with the disposal of untreated tannery-effluents.

  12. Decolorization and Degradation of Batik Dye Effluent using Ganoderma lucidum

    Science.gov (United States)

    Pratiwi, Diah; Indrianingsih, A. W.; Darsih, Cici; Hernawan

    2017-12-01

    Batik is product of traditional Indonesia culture that developed into a large textile industry. Synthetic dyes which widely used in textile industries including batik. Colour can be removed from wastewater effluent by chemical, physical, and biology methods. Bioremediation is one of the methods that used for processing colored effluent. Isolated White-rot fungi Ganoderma lucidum was used for bioremediation process for batik effluent. G. lucidum was developed by G. lucidum cultivation on centers of mushroom farmer Media Agro Merapi Kaliurang, Yogyakarta. The batik effluent was collected from a private small and medium Batik enterprises located at Petir, Rongkop, Gunungkidul Regency. The aim of the study were to optimize decolorization of Naphtol Black (NB) using G. lucidum. The effect of process parameters like incubation time and dye concentration on dye decolorization and COD degradation was studied. G. lucidum were growth at pH 5-6 and temperature 25°C at various Naphtol Black dye with concentration 20 ppm, 50 ppm, and 100 ppm for 30 day incubation time. The result from this study increased decolorization in line with the increasing of COD degradation. Increasing percentage of decolorization and COD degradation gradually increased with incubation time and dye concentration. The maximum decolorization and COD reduction were found to be 60,53% and 81,03%. G. lucidum had potential to decolorized and degraded COD for NB dye effluent on higher concentration.

  13. A risk-based approach to liquid effluent monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Hull, L.C.

    1995-10-01

    DOE Order 5400.1 identifies six objectives of a liquid effluent monitoring program. A strategy is proposed that meets these objective in one of two ways: (1) by showing that effluent concentrations are below concentration limits set by permits or are below concentrations that could cause environmental problems or (2) by showing that concentrations in effluent have not changed from a period when treatment processes were in control and there were no unplanned releases. The intensity of liquid effluent monitoring should be graded to the importance of the source being monitored. This can be accomplished by determining the risk posed by the source. A definition of risk is presented that defines risk in terms of the statistical probability of exceeding a release limit and the time available to recover from an exceedance of a release limit. Three examples are presented that show this approach to grading an effluent monitoring program can be implemented at the Idaho National Engineering Laboratory and will reduce monitoring requirements.

  14. Hanford Site Treated Effluent Disposal Facility process flow sheet

    International Nuclear Information System (INIS)

    Bendixsen, R.B.

    1993-04-01

    This report presents a novel method of using precipitation, destruction and recycle factors to prepare a process flow sheet. The 300 Area Treated Effluent Disposal Facility (TEDF) will treat process sewer waste water from the 300 Area of the Hanford Site, located near Richland, Washington, and discharge a permittable effluent flow into the Columbia River. When completed and operating, the TEDF effluent water flow will meet or exceed water quality standards for the 300 Area process sewer effluents. A preliminary safety analysis document (PSAD), a preconstruction requirement, needed a process flow sheet detailing the concentrations of radionuclides, inorganics and organics throughout the process, including the effluents, and providing estimates of stream flow quantities, activities, composition, and properties (i.e. temperature, pressure, specific gravity, pH and heat transfer rates). As the facility begins to operate, data from process samples can be used to provide better estimates of the factors, the factors can be entered into the flow sheet and the flow sheet will estimate more accurate steady state concentrations for the components. This report shows how the factors were developed and how they were used in developing a flow sheet to estimate component concentrations for the process flows. The report concludes with how TEDF sample data can improve the ability of the flow sheet to accurately predict concentrations of components in the process

  15. Monitoring of noble gas radioisotopes in nuclear power plant effluents

    International Nuclear Information System (INIS)

    Kabat, M.J.

    1985-01-01

    Monitoring of gaseous radionuclides in the effluents of nuclear facilities is an essential requirement in effluent management programs. Since there is no practical way of removing noble gas radioisotopes from air at release pathways, their accurate monitoring is essential for providing appropriate environmental protection. Emitted γ dose-rate is the limiting factor for concentration-time integral of noble gas in gaseous effluents of reactor facilities. The external exposure to the public from a semi-infinite cloud is directly proportional to both the noble gas isotope concentration and the integrated γ energy per disintegration. Both can be directly measured in gaseous effluent pathways with a suitable detector. The capability of NaI(T1), CaF 2 (Eu) and plastic scintillation detectors to measure the γ-Ci.MeV content of noble gas releases was experimentally evaluated. The combination of CaF 2 (Eu) detector in a pressurized through-flow chamber, with a charge integrating scaler well complied with both γ energy response and detection sensitivity requirements. Noble gas source terms and effluent monitoring criteria are discussed, theoretical and experimental results are presented and a practical, on-line noble gas monitoring system is described

  16. Optimizing Liquid Effluent Monitoring at a Large Nuclear Complex

    International Nuclear Information System (INIS)

    Chou, Charissa J.; Johnson, V.G.; Barnett, Brent B.; Olson, Phillip M.

    2003-01-01

    Monitoring data for a centralized effluent treatment and disposal facility at the Hanford Site, a defense nuclear complex undergoing cleanup and decommissioning in southeast Washington State, was evaluated to optimize liquid effluent monitoring efficiency. Wastewater from several facilities is collected and discharged to the ground at a common disposal site. The discharged water infiltrates through 60 m of soil column to the groundwater, which eventually flows into the Columbia River, the second largest river in the contiguous United States. Protection of this important natural resource is the major objective of both cleanup and groundwater and effluent monitoring activities at the Hanford Site. Four years of effluent data were evaluated for this study. More frequent sampling was conducted during the first year of operation to assess temporal variability in analyte concentrations, to determine operational factors contributing to waste stream variability and to assess the probability of exceeding permit limits. Subsequently, the study was updated which included evaluation of the sampling and analysis regime. It was concluded that the probability of exceeding permit limits was one in a million under normal operating conditions, sampling frequency could be reduced, and several analytes could be eliminated, while indicators could be substituted for more expensive analyses. Findings were used by the state regulatory agency to modify monitoring requirements for a new discharge permit. The primary focus of this paper is on the statistical approaches and rationale that led to the successful permit modification and to a more cost-effective effluent monitoring program

  17. Pollution from tanneries effluents and its impact on environment

    International Nuclear Information System (INIS)

    Rajput, A.A.; Memon, Hafeez-ur-Rahman; Sahto, M.H.

    1999-01-01

    The disposal of tanneries effluence has become one of the serious environmental problems. The effluents from tanneries contain highly toxic materials, including chromium salts, ammonium salts, acids, sodium sulphide and suspended solids. Hair, alkalinity, surfactants, dyes and oils are also present in these effluents. The extent of pollution depends upon the volume of the effluent discharged. Many studies have been carried out on the characteristics of these effluents in order to understand the nature of the effluents and their impact on environment. The present study shows measured values of different parameters like Biochemical Oxygen Demand (BOD) about 1950 mg/l, Chemical Oxygen Demand (COD) about 4500-4600 mg/l, suspended solids about 2600-2700 mg/l, dissolved solids 10000-12000 mg/l and lead, copper, chromium and cadmium about 2, 0.4, 64.4 and 0.31 mg/l respectively. The measured values are compared with that of previous. Some remedial measures for its treatment and disposal are also discussed. (author)

  18. Impact of fertilizer plant effluent on water quality

    International Nuclear Information System (INIS)

    Obire, O.; Ogan, A.; Okigbo, R. N.

    2008-01-01

    The impact of National Fertilizer Company of Nigeria out fall effluent on the physico chemistry and bacteriology of Okrika creek was investigated during the sampling period from May to December, 1998. The National Fertilizer Company of Nigeria out fall effluent, the Okrika creek water and the lkpukulubie creek (control) water samples were collected. The physico-chemical parameters analyzed for all the samples included temperature, p H, total chloride, total dissolved solids, dissolved oxygen, conductivity, free ammonia, total phosphate, urea, zinc and iron, while the bacteriological determinations were total culturable aerobic heterotrophic bacteria count and identification of representative isolates. The Okrika creek recorded higher concentrations for all the physicochemical parameters and bacteria load than the control creek. The higher values of p H, Free NH 3 , urea, TDS and the conductivity of the National Fertilizer Company of Nigeria out fall effluent above the FEPA standards reflect the poor effluent quality generated by National Fertilizer Company of Nigeria. The bacteria species isolated from the samples include Aerococcus viridans, Alcaligenes faecalis, Bacillus cereus, Citrobacter freundii, Escherichia coli, Klebsiella pneumoniae, Proteus vulgaris, Pseudomonas aeruginosa, Serratia marcescens and Staphylococcus aureus. In general, the investigation revealed that there was an extremely adverse impact on the physico-chemical and bacteriological water quality characteristics of the Okrika creek as a result of the discharge of poor quality effluent from National Fertilizer Company of Nigeria operations

  19. Demasculinization of male fish by wastewater treatment plant effluent

    Science.gov (United States)

    Vajda, A.M.; Barber, L.B.; Gray, J.L.; Lopez, E.M.; Bolden, A.M.; Schoenfuss, H.L.; Norris, D.O.

    2011-01-01

    Adult male fathead minnows (Pimephales promelas) were exposed to effluent from the City of Boulder, Colorado wastewater treatment plant (WWTP) under controlled conditions in the field to determine if the effluent induced reproductive disruption in fish. Gonadal intersex and other evidence of reproductive disruption were previously identified in white suckers (Catostomus commersoni) in Boulder Creek downstream from this WWTP effluent outfall. Fish were exposed within a mobile flow-through exposure laboratory in July 2005 and August 2006 to WWTP effluent (EFF), Boulder Creek water (REF), or mixtures of EFF and REF for up to 28 days. Primary (sperm abundance) and secondary (nuptial tubercles and dorsal fat pads) sex characteristics were demasculinized within 14 days of exposure to 50% and 100% EFF. Vitellogenin was maximally elevated in both 50% and 100% EFF treatments within 7 days and significantly elevated by 25% EFF within 14 days. The steroidal estrogens 17??-estradiol, estrone, estriol, and 17??-ethynylestradiol, as well as estrogenic alkylphenols and bisphenol A were identified within the EFF treatments and not in the REF treatment. These results support the hypothesis that the reproductive disruption observed in this watershed is due to endocrine-active chemicals in the WWTP effluent. ?? 2011 Elsevier B.V.

  20. A Novel Methylotrophic Bacterial Consortium for Treatment of Industrial Effluents.

    Science.gov (United States)

    Hingurao, Krushi; Nerurkar, Anuradha

    2018-01-01

    Considering the importance of methylotrophs in industrial wastewater treatment, focus of the present study was on utilization of a methylotrophic bacterial consortium as a microbial seed for biotreatment of a variety of industrial effluents. For this purpose, a mixed bacterial methylotrophic AC (Ankleshwar CETP) consortium comprising of Bordetella petrii AC1, Bacillus licheniformis AC4, Salmonella subterranea AC5, and Pseudomonas stutzeri AC8 was used. The AC consortium showed efficient biotreatment of four industrial effluents procured from fertilizer, chemical and pesticide industries, and common effluent treatment plant by lowering their chemical oxygen demand (COD) of 950-2000 mg/l to below detection limit in 60-96 h in 6-l batch reactor and 9-15 days in 6-l continuous reactor. The operating variables of wastewater treatment, viz. COD, BOD, pH, MLSS, MLVSS, SVI, and F/M ratio of these effluents, were also maintained in the permissible range in both batch and continuous reactors. Therefore, formation of the AC consortium has led to the development of an efficient microbial seed capable of treating a variety of industrial effluents containing pollutants generated from their respective industries.

  1. A risk-based approach to liquid effluent monitoring

    International Nuclear Information System (INIS)

    Hull, L.C.

    1995-10-01

    DOE Order 5400.1 identifies six objectives of a liquid effluent monitoring program. A strategy is proposed that meets these objective in one of two ways: (1) by showing that effluent concentrations are below concentration limits set by permits or are below concentrations that could cause environmental problems or (2) by showing that concentrations in effluent have not changed from a period when treatment processes were in control and there were no unplanned releases. The intensity of liquid effluent monitoring should be graded to the importance of the source being monitored. This can be accomplished by determining the risk posed by the source. A definition of risk is presented that defines risk in terms of the statistical probability of exceeding a release limit and the time available to recover from an exceedance of a release limit. Three examples are presented that show this approach to grading an effluent monitoring program can be implemented at the Idaho National Engineering Laboratory and will reduce monitoring requirements

  2. [Newly Designed Water Treatment Systems for Hospital Effluent].

    Science.gov (United States)

    Azuma, Takashi

    2018-01-01

     Pharmaceuticals are indispensable to contemporary life. Recently, the emerging problem of pharmaceutical-based pollution of river environments, including drinking water sources and lakes, has begun to receive significant attention worldwide. Because pharmaceuticals are designed to perform specific physiological functions in targeted regions of the human body, there is increasing concern regarding their toxic effects, even at low concentrations, on aquatic ecosystems and human health, via residues in drinking water. Pharmaceuticals are consistently employed in hospitals to treat disease; and Japan, one of the most advanced countries in medical treatment, ranks second worldwide in the quantity of pharmaceuticals employed. Therefore, the development of technologies that minimize or lessen the related environmental risks for clinical effluent is an important task as well as that for sewage treatment plants (STPs). However, there has been limited research on clinical effluent, and much remains to be elucidated. In light of this, we are investigating the occurrence of pharmaceuticals, and the development of water treatment systems for clinical effluent. This review discusses the current research on clinical effluent and the development of advanced water treatment systems targeted at hospital effluent, and explores strategies for future environmental risk assessment and risk management.

  3. Complete physico-chemical treatment for coke plant effluents.

    Science.gov (United States)

    Ghose, M K

    2002-03-01

    Naturally found coal is converted to coke which is suitable for metallurgical industries. Large quantities of liquid effluents produced contain a large amount of suspended solids, high COD, BOD, phenols, ammonia and other toxic substances which are causing serious pollution problem in the receiving water to which they are discharged. There are a large number of coke plants in the vicinity of Jharia Coal Field (JCF). Characteristics of the effluents have been evaluated. The present effluent treatment systems were found to be inadequate. Physico-chemical treatment has been considered as a suitable option for the treatment of coke plant effluents. Ammonia removal by synthetic zeolite, activated carbon for the removal of bacteria, viruses, refractory organics, etc. were utilized and the results are discussed. A scheme has been proposed for the complete physico-chemical treatment, which can be suitably adopted for the recycling, reuse and safe disposal of the treated effluent. Various unit process and unit operations involved in the treatment system have been discussed. The process may be useful on industrial scale at various sites.

  4. Ecotoxicological risks associated with tannery effluent wastewater.

    Science.gov (United States)

    Shakir, Lubna; Ejaz, Sohail; Ashraf, Muhammad; Qureshi, Naureen Aziz; Anjum, Aftab Ahmad; Iltaf, Imran; Javeed, Aqeel

    2012-09-01

    The problem of water pollution acquires greater relevance in the context of a developing agrarian economy like Pakistan. Even though, the leather industry is a leading economic sector in Pakistan, there is an increasing environmental concern regarding tanneries because they produce large amounts of potentially toxic wastewater containing both trivalent and hexavalent chromium, which are equally hazardous for human population, aquaculture and agricultural activities in the area. Therefore, we defined the scope of the present study as to employ different bioassays to determine the eco-toxic potential of tannery effluent wastewater (TW) and its chromium based components, i.e., potassium dichromate (K(2)Cr(2)O(7)) and chromium sulfate Cr(2)(SO(4))(3). Particle-induced X-ray emission (PIXE) analysis of TW was carried out to determine the concentration of chromium in TW and then equal concentrations of hexavalent (K(2)Cr(2)O(7)) and trivalent chromium Cr(2)(SO(4))(3) were obtained for this study. Cytotoxicity assay, artemia bioassay and phytotoxicity assay was utilized to investigate the eco-toxicological potential of different concentrations of TW, K(2)Cr(2)O(7) and Cr(2)(SO(4))(3). All the dilutions of TW, K(2)Cr(2)O(7) and Cr(2)(SO(4))(3) presented concentration dependent cytotoxic effects in these assays. The data clearly represents that among all three tested materials, different dilutions of K(2)Cr(2)O(7) caused significantly more damage (P<0.001) to vero cell, brine shrimp and germination of maize seeds. Interestingly, the overall toxicity effects of TW treated groups were subsequent to K(2)Cr(2)O(7) treated group. Based on biological evidences presented in this article, it is concluded that hexavalent chromium (K(2)Cr(2)O(7)) and TW has got significant eco-damaging potential clearly elaborating that environmental burden in district Kasur is numerous and high levels of chromium is posing a considerable risk to the human population, aquaculture and agricultural

  5. Effluent dispersion in natural water receivers (tracer examination)

    International Nuclear Information System (INIS)

    Szpilowski, S.; Owczarczyk, A.; Chmielewski, A.G.

    1993-01-01

    Tracer methods constitute very convenient means for observation and examination of effluent dispersion and dilution processes in natural water receivers. In the report there are presented methods developed and used by the Institute of Nuclear Chemistry and Technology (INCT) to measure mixing parameters in natural streams to determine distances of complete transverse mixing as well as to assess and predict dispersion of sewage in large water reservoirs. There are also presented the methods of predicting initial stage of dispersion of sewage discharged into large water reservoirs through underwater out falls and the method for determining the decomposition rates of effluent entering a natural water receiver. The methods presented can be used in analysis of pollution in a given water region, in selection of optimal sewage out fall locations as well as in prediction of effluent dilution intensity at different hydro- and meteorological conditions. (author). 27 refs, 15 figs, 2 tabs

  6. Design parameters for waste effluent treatment unit from beverages production

    Directory of Open Access Journals (Sweden)

    Mona A. Abdel-Fatah

    2017-09-01

    Full Text Available Based on a successful experimental result from laboratory and bench scale for treatment of wastewater from beverages industry, an industrial and efficient treatment unit is designed and constructed. The broad goal of this study was to design and construct effluent, cost effective and high quality treatment unit. The used technology is the activated sludge process of extended aeration type followed by rapid sand filters and chlorination as tertiary treatment. Experimental results have been considered as the basis for full scale design of the industrial capacity of 1600 m3/day treatment plant. Final effluent characteristics after treatment comply with Egyptian legalizations after reducing COD and BOD5 by about 97% and 95% respectively. So it is recommended to reuse treated effluent in textile industry in dyeing process.

  7. Atomics International environmental monitoring and facility effluent annual report, 1976

    International Nuclear Information System (INIS)

    Moore, J.D.

    1977-01-01

    Environmental and facility effluent radioactivity monitoring at Atomics International (AI) is performend by the Radiation and Nuclear Safety Unit of the Health, Safety, and Radiation Services Department. Soil, vegetation, and surface water are routinely sampled to a distance of 10 miles from AI sites. Continuous ambient air sampling and thermoluminescent dosimetry are performed on site for monitoring airborne radioactivity and site ambient radiation levels. Radioactivity in effluents discharged to the atmosphere from AI facilities is continuously sampled and monitored to ensure that levels released to unrestricted areas are within appropriate limits, and to identify processes which may require additional engineering safeguards to minimize radioactivity levels in such effluents. In addition, selected nonradioactive constituents in surface water discharged to unrestricted areas are determined. This report summarizes and discusses monitoring results for 1976. The results of a special soil plutonium survey performed during the year are also summarized

  8. Facility effluent monitoring plan for the 324 Facility

    International Nuclear Information System (INIS)

    1994-11-01

    The 324 Facility [Waste Technology Engineering Laboratory] in the 300 Area primarily supports the research and development of radioactive and nonradioactive waste vitrification technologies, biological waste remediation technologies, spent nuclear fuel studies, waste mixing and transport studies, and tritium development programs. All of the above-mentioned programs deal with, and have the potential to, release hazardous and/or radioactive material. The potential for discharge would primarily result from (1) conducting research activities using the hazardous materials, (2) storing radionuclides and hazardous chemicals, and (3) waste accumulation and storage. This report summarizes the airborne and liquid effluents, and the results of the Facility Effluent Monitoring Plan (FEMP) determination for the facility. The complete monitoring plan includes characterizing effluent streams, monitoring/sampling design criteria, a description of the monitoring systems and sample analysis, and quality assurance requirements

  9. Evaluation of dairy effluent management options using multiple criteria analysis.

    Science.gov (United States)

    Hajkowicz, Stefan A; Wheeler, Sarah A

    2008-04-01

    This article describes how options for managing dairy effluent on the Lower Murray River in South Australia were evaluated using multiple criteria analysis (MCA). Multiple criteria analysis is a framework for combining multiple environmental, social, and economic objectives in policy decisions. At the time of the study, dairy irrigation in the region was based on flood irrigation which involved returning effluent to the river. The returned water contained nutrients, salts, and microbial contaminants leading to environmental, human health, and tourism impacts. In this study MCA was used to evaluate 11 options against 6 criteria for managing dairy effluent problems. Of the 11 options, the MCA model selected partial rehabilitation of dairy paddocks with the conversion of remaining land to other agriculture. Soon after, the South Australian Government adopted this course of action and is now providing incentives for dairy farmers in the region to upgrade irrigation infrastructure and/or enter alternative industries.

  10. Using solvent extraction to process nitrate anion exchange column effluents

    International Nuclear Information System (INIS)

    Yarbro, S.L.

    1987-10-01

    Octyl(phenyl)-N,N-diisobutylcarbamoylmethylphosphine oxide (CMPO), a new organophosphorous extractant, and a new centrifugal mixer-settler both recently developed at Argonne were evaluated for their potential use in the recovery of actinides from nitrate anion exchange column effluents. The performance of the extractant was evaluated by measuring the extraction coefficient values as a function of acid and salt concentration. Additional performance parameters include extraction coefficient behavior as a function of the total metal concentration in the organic phase, and comparison of different stripping and organic scrubbing techniques. A simulated effluent stream was used to evaluate the performance of the centrifugal mixer-settlers by comparing experimental and calculated interstage concentration profiles. Both the CMPO extractant and the centrifugal mixer-settlers have potential for processing nitrate column effluents, particularly if the stripping behavior can be improved. Details of the proposed process are presented in the flowsheet and contactor design analyses

  11. Using solvent extraction to process nitrate anion exchange column effluents

    Energy Technology Data Exchange (ETDEWEB)

    Yarbro, S.L.

    1987-10-01

    Octyl(phenyl)-N,N-diisobutylcarbamoylmethylphosphine oxide (CMPO), a new organophosphorous extractant, and a new centrifugal mixer-settler both recently developed at Argonne were evaluated for their potential use in the recovery of actinides from nitrate anion exchange column effluents. The performance of the extractant was evaluated by measuring the extraction coefficient values as a function of acid and salt concentration. Additional performance parameters include extraction coefficient behavior as a function of the total metal concentration in the organic phase, and comparison of different stripping and organic scrubbing techniques. A simulated effluent stream was used to evaluate the performance of the centrifugal mixer-settlers by comparing experimental and calculated interstage concentration profiles. Both the CMPO extractant and the centrifugal mixer-settlers have potential for processing nitrate column effluents, particularly if the stripping behavior can be improved. Details of the proposed process are presented in the flowsheet and contactor design analyses.

  12. Phytoremediation potential of aquatic herbs from steel foundry effluent

    Directory of Open Access Journals (Sweden)

    N. Aurangzeb

    2014-12-01

    Full Text Available Discharge of industrial effluents in aquatic environments is a serious threat to life due to toxic heavy metals. Plants can be used as cheap phytoremedients in comparison to conventional technologies. The present study was conducted to check the phytoremediation capability of two free-floating plants, i.e., Pistia stratiotes and Eichhornia crassipes, for the removal of heavy metals from steel effluent by using Atomic Absorption Spectrophotometry. P. stratiotes was able to remove some of the heavy metals, showing the highest affinity for Pb and Cu with 70.7% and 66.5% efficiency, respectively, while E. crassipes proved to be the best phytoremediant for polluted water as its efficiency was greatest progressively for Cd, Cu, As, Al and Pb, i.e., 82.8%, 78.6%, 74%, 73% and 73%, respectively. In conclusion, aquatic plants can be a better candidate for phytoextraction from industrial effluents due to cost effectiveness.

  13. Radiological Effluent Technical Specifications (RETS) implementation, Kewaunee Nuclear Power Plant

    International Nuclear Information System (INIS)

    Serrano, W.; Akers, D.W.

    1985-06-01

    A review of the Radiological Effluent Technical Specifications (RETS) for the Kewaunee Nuclear Power Plant was performed. The principal review guidelines used were NUREG-0133, ''Preparation of Radiological Effluent Technical Specifications for Nuclear Power Plants,'' and Draft 7'' of NUREG-0472, Revision 3, ''Radiological Effluent Technical Specifications for Pressurized Water Reactors.'' Draft submittals were discussed with the Licensee by the NRC staff until all items requiring changes to the Technical Specifications were resolved. The Licensee then submitted final proposed RETS to the NRC which were evaluated and found to be in compliance with the NRC review guidelines. The proposed Offsite Dose Calculation Manual and the Radiological Environmental Monitoring Manual were reviewed and generally found to be in compliance with the NRC review guidelines

  14. Characterisation of the ecotoxicity of hospital effluents: a review.

    Science.gov (United States)

    Orias, Frédéric; Perrodin, Yves

    2013-06-01

    The multiple activities that take place in hospitals (surgery, drug treatments, radiology, cleaning of premises and linen, chemical and biological analysis laboratories, etc.), are a major source of pollutant emissions into the environment (disinfectants, detergents, drug residues, etc.). Most of these pollutants can be found in hospital effluents (HWW), then in urban sewer networks and WWTP (weakly adapted for their treatment) and finally in aquatic environments. In view to evaluating the impact of these pollutants on aquatic ecosystems, it is necessary to characterise their ecotoxicity. Several reviews have focused on the quantitative and qualitative characterisation of pollutants present in HWW. However, none have focused specifically on the characterisation of their experimental ecotoxicity. We have evaluated this according to two complementary approaches: (i) a "substance" approach based on the identification of the experimental data in the literature for different substances found in hospital effluents, and on the calculation of their PNEC (Predicted Non Effect Concentration), (ii) a "matrix" approach for which we have synthesised ecotoxicity data obtained from the hospital effluents directly. This work first highlights the diversity of the substances present within hospital effluents, and the very high ecotoxicity of some of them (minimum PNEC observed close to 0,01 pg/L). We also observed that the consumption of drugs in hospitals was a predominant factor chosen by authors to prioritise the compounds to be sought. Other criteria such as biodegradability, excretion rate and the bioaccumulability of pollutants are considered, though more rarely. Studies of the ecotoxicity of the particulate phase of effluents must also be taken into account. It is also necessary to monitor the effluents of each of the specialised departments of the hospital studied. These steps is necessary to define realistic environmental management policies for hospitals (replacement of

  15. Facility effluent monitoring plan for the uranium trioxide facility

    International Nuclear Information System (INIS)

    Thompson, R.J.; Sontag, S.

    1991-11-01

    A facility effluent monitoring plant is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan is the first annual report. It shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated as a minimum every three years. The UO 3 Plant is located in the south-central portion of the 200 West Area of the Hanford Site. The plant consists of two primary processing buildings and several ancillary facilities. The purpose of the UO 3 Plant is to receive uranyl nitrate hexahydrate (UNH) from the Plutonium-Uranium Extraction (PUREX) Plant, concentrate it, convert the UNH to uranium trioxide (UO 3 ) powder by calcination and package it for offsite shipment. The UO 3 Plant has been placed in a standby mode. There are two liquid discharges, and three gaseous exhaust stacks, and seven building exhausters that are active during standby conditions

  16. Facility effluent monitoring plan for the tank farms facilities

    International Nuclear Information System (INIS)

    Crummel, G.M.; Gustavson, R.D.; Kenoyer, J.L.; Moeller, M.P.

    1991-11-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan is the first annual report. It shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated as a minimum three years. A variety of liquid wastes are generated in processing treatment, and disposal operations throughout the Hanford Site. The Tank Farms Project serves a major role in Hanford Site waste management activities as the temporary repository for these wastes. Stored wastes include hazardous components regulated under the Resource Conservation and Recovery Act of 1976 (RCRA) and as by-product material regulated under the Atomic Energy Act of 1954. A total of 177 single- and double-shell tanks (SST and DST) have been constructed in the 200 East and 200 West Areas of the Hanford Site. These facilities were constructed to various designs from 1943 to 1986. The Tank Farms Project is comprised of these tanks along with various transfer, receiving, and treatment facilities

  17. Major ion toxicity in effluents: A review with permitting recommendations

    Energy Technology Data Exchange (ETDEWEB)

    Goodfellow, W.L.; Ausley, L.W.; Burton, D.T.; Denton, D.L.; Dorn, P.B.; Grothe, D.R.; Heber, M.A.; Norberg-King, T.J.; Rodgers, J.H. Jr.

    2000-01-01

    Effluent toxicity testing methods have been well defined, but for the most part, these methods do not attempt to segregate the effects of active ionic concentrations and ion imbalances upon test and species performances. The role of various total dissolved solids in effluents on regulatory compliance has emerged during the last few years and has caused confusion in technical assessment and in permitting and compliance issues. This paper assesses the issue of ionic strength and ion imbalance, provides a brief summary of applicable data, presents several case studies demonstrating successful tools to address toxicity resulting from salinity and ion imbalance, and provides recommendations for regulatory and compliance options to manage discharges with salinity/ion imbalance issues. Effluent toxicity resulting from inorganic ion imbalance and the ion concentration of the effluent is pervasive in permitted discharge from many industrial process and municipal discharges where process streams are concentrated, adjusted, or modified. This paper discusses procedures that use weight-of-evidence approaches to identify ion imbalance toxicity, including direct measurement, predictive toxicity models for freshwater, exchange resins, mock effluents, and ion imbalance toxicity with tolerant/susceptible test species. Cost-effective waste treatment control options for a facility whose effluent is toxic because of total dissolved solids (TDS) or because of specific ion(s) are scarce at best. Depending on the discharge situation, TDS toxicity may not be viewed with the same level of concern as other, more traditional, toxicants. These discharge situations often do not require the conservative safety factors required by other toxicants. Selection of the alternative regulatory solutions discussed in this paper may be beneficial, especially because they do not require potentially expensive or high-energy-using treatment options that may be ineffective control options. The information

  18. Dose apportionment using statistical modeling of the effluent release

    International Nuclear Information System (INIS)

    Datta, D.

    2011-01-01

    Nuclear power plants are always operated under the guidelines stipulated by the regulatory body. These guidelines basically contain the technical specifications of the specific power plant and provide the knowledge of the discharge limit of the radioactive effluent into the environment through atmospheric and aquatic route. However, operational constraints sometimes may violate the technical specification due to which there may be a failure to satisfy the stipulated dose apportioned to that plant. In a site having multi facilities sum total of the dose apportioned to all the facilities should be constrained to 1 mSv/year to the members of the public. Dose apportionment scheme basically stipulates the limit of the gaseous and liquid effluent released into the environment. Existing methodology of dose apportionment is subjective in nature that may result the discharge limit of the effluent in atmospheric and aquatic route in an adhoc manner. Appropriate scientific basis for dose apportionment is always preferable rather than judicial basis from the point of harmonization of establishing the dose apportionment. This paper presents an attempt of establishing the discharge limit of the gaseous and liquid effluent first on the basis of the existing value of the release of the same. Existing release data for a few years (for example 10 years) for any nuclear power station have taken into consideration. Bootstrap, a resampling technique, has been adopted on this data sets to generate the population which subsequently provide the corresponding population distribution of the effluent release. Cumulative distribution of the population distribution obtained is constructed and using this cumulative distribution, 95th percentile (upper bound) of the discharge limit of the radioactive effluents is computed. Dose apportioned for a facility is evaluated using this estimated upper bound of the release limit. Paper describes the detail of the bootstrap method in evaluating the

  19. Nuclear power and other thermal power

    International Nuclear Information System (INIS)

    Bakke, J.

    1978-01-01

    Some philosophical aspects of mortality statistics are first briefly mentioued, then the environmental problems of, first, nuclear power plants, then fossil fuelled power plants are summarised. The effects of releases of carbon dioxide, sulphur dioxide and nitrogen oxides are briefly discussed. The possible health effects of radiation from nuclear power plants and those of gaseous and particulate effluents from fossil fuel plants are also discussed. It is pointed out that in choosing between alternative evils the worst course is to make no choice at all, that is, failure to install thermal power plants will lead to isolated domestic burning of fossil fuels which is clearly the worst situation regarding pollution. (JIW)

  20. Thermal effects on the Savannah River

    International Nuclear Information System (INIS)

    Patrick, R.

    1981-01-01

    The effects of thermal effluents from the Savannah River Plant (SRP), particularly during periods when the L Reactor was operative, on the structure and health of the aquatic communities of organisms in the Savannah River have been determined. Portions of the data base collected by the Academy of Natural Sciences since 1951 on the Savannah River were used. The organisms belonging to various groups of aquatic life were identified to species if possible. The relative abundance of the species was estimated for the more common species. The bacteriological, chemical and physical characteristics of the water were determined

  1. Modelling anaerobic codigestion of manure with olive oil mill effluent

    DEFF Research Database (Denmark)

    Angelidaki, I.; Ellegaard, L.; Ahring, B.K.

    1997-01-01

    A mathematical model describing the combined anaerobic degradation of complex organic material, such as manure, and a lipid containing additive, such as olive oil mill effluents, has been developed based on a model previously described (Angelidaki et al. 1993). The model has been used to simulate...... anaerobic codigestion of cattle manure together with olive oil mill effluent (OME) and the simulations were compared with experimental data. Simulation data indicated that lack of ammonia, needed as nitrogen source for synthesis of bacterial biomass and as an important pH buffer, could be responsible...

  2. Systems engineering implementation plan for the liquid effluents services program

    International Nuclear Information System (INIS)

    Lowe, S.S.

    1995-01-01

    A graded approach is being taken by the Liquid Effluents Services Program in implementing systems engineering because of the advanced state of the program. The approach is cost-effective and takes credit for related work already completed, yet retains the benefits of systems engineering. This plan describes how the Liquid Effluents Services Program will implement systems engineering so there is a common understanding. Systems engineering work to be performed and the products of that work are identified. The relation to the current planning process and integration with the sitewide systems engineering effort is described

  3. The use of magnetite for decontaminating alpha containing effluents

    International Nuclear Information System (INIS)

    Ivens, R.

    1988-06-01

    The feasibility of retention of precipitated magnetite by magnetic filtration followed by direct cementation offered an attractive alternative to conventional ferric hydroxide treatment of radioactive liquid effluents. The magnetically-assisted dewatering of laboratory-prepared magnetite was examined in a number of ways, none of which achieved the desired optimum solids content for cementation. Attempts to prepare magnetite in situ from typical effluents containing iron were unsuccessful owing to the presence of interfering ions. Preformed magnetite was reasonably effective at absorbing actinides from solution but did not appear to offer any significant advantage over ferric hydroxide. (author)

  4. Airborne effluent control for LMFBR fuel reprocessing plants

    International Nuclear Information System (INIS)

    Yarbro, O.O.; Groenier, W.S.; Stephenson, M.J.

    1976-01-01

    A significant part of the LMFBR fuel reprocessing development program has been devoted to the development of efficient removal systems for the volatile fission products, including 131 I, krypton, tritium, 129 I, and most recently 14 C. Flowsheet studies have indicated that very significant reductions of radioactive effluents can be achieved by integrating advanced effluent control systems with new concepts of containment and ventilation; however, the feasibility of such has not yet been established, nor have the economics been examined. This paper presents a flowsheet for the application of advanced containment systems to the processing of LMFBR fuels and summarizes the status and applicability of specific fission product removal systems

  5. Fusion fuel cycle: material requirements and potential effluents

    International Nuclear Information System (INIS)

    Teofilo, V.L.; Bickford, W.E.; Long, L.W.; Price, B.A.; Mellinger, P.J.; Willingham, C.E.; Young, J.K.

    1980-10-01

    Environmental effluents that may be associated with the fusion fuel cycle are identified. Existing standards for controlling their release are summarized and anticipated regulatory changes are identified. The ability of existing and planned environmental control technology to limit effluent releases to acceptable levels is evaluated. Reference tokamak fusion system concepts are described and the principal materials required of the associated fuel cycle are analyzed. These materials include the fusion fuels deuterium and tritium; helium, which is used as a coolant for both the blanket and superconducting magnets; lithium and beryllium used in the blanket; and niobium used in the magnets. The chemical and physical processes used to prepare these materials are also described

  6. Bentonite chemical modification for use in industrial effluents

    International Nuclear Information System (INIS)

    Laranjeira, E.; Pinto, M.R.O.; Rodrigues, D.P.; Costa, B.P.; Guimaraes, P.L.F.

    2010-01-01

    The present work aims at synthesizing organoclays using a layered silicate of regional importance, bentonite clay, for the treatment of industrial effluents. The choice of clay to be organophilized was based on cation exchange capacity (CEC). Bentonite with higher CTC was called AN 35 (92 meq/100 g), and therefore was the one that suffered the chemical modification with salt cetyl trimethyl ammonium Cetremide, provided by Vetec.The unmodified and modified clays were characterized by FTIR and XDR. The data obtained through the characterizations confirmed the acquisition of bentonite organoclay thus suggesting its subsequent application in the treatment of industrial effluents. (author)

  7. Fusion fuel cycle: material requirements and potential effluents

    Energy Technology Data Exchange (ETDEWEB)

    Teofilo, V.L.; Bickford, W.E.; Long, L.W.; Price, B.A.; Mellinger, P.J.; Willingham, C.E.; Young, J.K.

    1980-10-01

    Environmental effluents that may be associated with the fusion fuel cycle are identified. Existing standards for controlling their release are summarized and anticipated regulatory changes are identified. The ability of existing and planned environmental control technology to limit effluent releases to acceptable levels is evaluated. Reference tokamak fusion system concepts are described and the principal materials required of the associated fuel cycle are analyzed. These materials include the fusion fuels deuterium and tritium; helium, which is used as a coolant for both the blanket and superconducting magnets; lithium and beryllium used in the blanket; and niobium used in the magnets. The chemical and physical processes used to prepare these materials are also described.

  8. Cleanup Verification Package for the 116-K-2 Effluent Trench

    International Nuclear Information System (INIS)

    Capron, J.M.

    2006-01-01

    This cleanup verification package documents completion of remedial action for the 116-K-2 effluent trench, also referred to as the 116-K-2 mile-long trench and the 116-K-2 site. During its period of operation, the 116-K-2 site was used to dispose of cooling water effluent from the 105-KE and 105-KW Reactors by percolation into the soil. This site also received mixed liquid wastes from the 105-KW and 105-KE fuel storage basins, reactor floor drains, and miscellaneous decontamination activities

  9. Effect of surface treatment of tailings on effluent quality

    International Nuclear Information System (INIS)

    Murray, D.R.; Okuhara, D.

    1980-01-01

    Lysimeters containing 125 tons of mine tailings were used to determine the impact of gravel, sawdust, and vegetation as surface treatments on the quality and quantity of effluent produced from sulfide-containing uranium mill tailings. Over a 5-yr period, treatments did not alter the effluent quality to a level acceptable to regulatory requirements. The concentration of iron, copper, lead, aluminum, and sulfate increased with the rise of acidity during this period. However, the rate and extent of changes did vary with the treatment. The role of surface treatment in long-term waste abandonment must be investigated further

  10. Chemical investigation of sewage effluents of Hyderabad city

    International Nuclear Information System (INIS)

    Laghari, A.; Chandio, S.N.; Khushawar, M.Y.; Laghari, M.Y.

    2000-01-01

    Water samples of sewage effluents were collected from sewage collection points located at Latifabad units 9-11, Husainabad and Qasimabad sewage pumping stations. The sewage is pumped towards Southern Sewage treatment plant (SSTP) or is used for agricultural purposes. The water samples from SSTP were also collected and analyzed for pH, conducively, salinity, alkalinity, chlorides, hardness, total, volatile and fixed residues, dissolved oxygen, chemical oxygen demand, nitrogen and phosphorous contents. Variation in the results between sewage water and effluents were noted. (author)

  11. High sensitivity on-line monitor for radioactive effluent

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, Toshimi [Tohoku Electric Power Co. Ltd., Sendai (Japan); Ishizuka, Akira; Abe, Eisuke; Inoue, Yasuhiko; Fujii, Masaaki; Kitaguchi, Hiroshi; Doi, Akira

    1983-04-01

    A new approach for a highly sensitive effluent monitor is presented. The free flow type monitor, which consists of a straightener, nozzle, monitoring section and ..gamma..-ray detector, is demonstrated to be effective in providing long term stability. The 160 start-and-stop cycles of effluent discharge were repeated in a 120-h testing period. Results showed a background increase was not observed for the free flow type monitor. The background count rate was calibrated to the lowest detection limit to be 2.2 x 10/sup -2/ Bq/ml for a 300 s measurement time.

  12. Radioactive effluents in the Savannah River: Summary report for 1989

    International Nuclear Information System (INIS)

    Winn, W.G.

    1991-09-01

    Researchers at the Savannah River Site have low-level radiometric studies of the Savannah River to distinguish between the effluent contributions of the Savannah River Site and Plant Vogtle. Since the startup of Plant Vogtle in 1987, researchers have routinely detected neutron-activated isotopes in controlled releases, but all have routinely detected neutron-activated isotopes in controlled releases, but all have been well below the Department of Energy's (DOE) guidelines. The study has found that processing improvement at Plant Vogtle during 1989 have lowered the activities of effluents from Plant Vogtle. These studies will continue on a routine basis because they provide disturbing trends before actual health concerns evolve

  13. Bio-decolourization of textile effluent containing Reactive Black-B by ...

    African Journals Online (AJOL)

    STORAGESEVER

    2008-09-17

    Sep 17, 2008 ... certain selected effluent soil-adapted and non-adapted bacteria to decolourize an actual textile effluent ... Microbial decolourization and degradation is an ... was collected in a 10 liter plastic can and refrigerated till use.

  14. Water quality changes due to abattoir effluent: A case on Mchesa ...

    African Journals Online (AJOL)

    user

    impact of effluent from Shire Valley Abattoir on the physico-chemical parameters of Mchesa Stream in. Blantyre. Water ... Sampling point located 10m downstream from effluent discharge. S50 ..... Similar studies done in Mudi River (Masamba.

  15. The effects of Niger State water treatment plant effluent on its ...

    African Journals Online (AJOL)

    STORAGESEVER

    2008-05-16

    May 16, 2008 ... The effect of water treatment plant effluent on its receiving river (Kaduna) was examined. Samples were ... Agency (FEPA) limits for effluent discharge into surface water. .... municipal sewage, garbages, domestic and industrial.

  16. 78 FR 277 - Section 610 Review of NPDES Permit Regulation and Effluent Limitations Guidelines Standards for...

    Science.gov (United States)

    2013-01-03

    ..., Section 610 Review of NPDES Permit Regulation and Effluent Limitations Guidelines Standards for..., FRL-9764-8] Section 610 Review of NPDES Permit Regulation and Effluent Limitations Guidelines Standards for Concentrated Animal Feeding Operations (CAFOs); Extension of Comment Period AGENCY...

  17. Removal of heavy metals from metal-containing effluent by yeast ...

    African Journals Online (AJOL)

    Removal of heavy metals from metal-containing effluent by yeast biomass. ... Research studies have described this phenomenon of fast initial sorption with a ... chrome and tin from the chrome and tin effluents of a local iron and steel industry.

  18. Assessment of wastewater treatment plant effluent on fish reproduction utilizing the adverse outcome pathway conceptual framework

    Science.gov (United States)

    Wastewater treatment plant (WWTP) effluents are a known contributor of chemical mixture inputs into the environment. Whole effluent testing guidelines were developed to screen these complex mixtures for acute toxicity. However, efficient and cost-effective approaches for screenin...

  19. Temporal Variation in the Estrogenicity of a Sewage Treatment Plant Effluent and its Biological Significance

    Science.gov (United States)

    This paper describes variations in the estrogenic potency of effluent from a "model" wastewater treatment plant in Duluth, MN, and explores the significance of these variations relative to sampling approaches for monitoring effluents and their toxicity to fish.

  20. Impact analysis of palm oil mill effluent on the aerobic bacterial ...

    African Journals Online (AJOL)

    AJB SERVER

    2007-01-18

    Jan 18, 2007 ... Key words: Palm oil mill effluent, total aerobic bacteria, ammonium oxidizers. INTRODUCTION ... bacteria help in the degradation of macromolecules from plant and animal .... Anaerobic digestion of palm oil mill effluent.

  1. Polishing of Anaerobic Secondary Effluent and Symbiotic Bioremediation of Raw Municipal Wastewater by Chlorella Vulgaris

    KAUST Repository

    Cheng, Tuoyuan

    2016-01-01

    To assess polishing of anaerobic secondary effluent and symbiotic bioremediation of primary effluent by microalgae, bench scale bubbling column reactors were operated in batch modes to test nutrients removal capacity and associated factors. Chemical

  2. Thermal expansion

    International Nuclear Information System (INIS)

    Yun, Y.

    2015-01-01

    Thermal expansion of fuel pellet is an important property which limits the lifetime of the fuels in reactors, because it affects both the pellet and cladding mechanical interaction and the gap conductivity. By fitting a number of available measured data, recommended equations have been presented and successfully used to estimate thermal expansion coefficient of the nuclear fuel pellet. However, due to large scatter of the measured data, non-consensus data have been omitted in formulating the equations. Also, the equation is strongly governed by the lack of appropriate experimental data. For those reasons, it is important to develop theoretical methodologies to better describe thermal expansion behaviour of nuclear fuel. In particular, first-principles and molecular dynamics simulations have been certainly contributed to predict reliable thermal expansion without fitting the measured data. Furthermore, the two theoretical techniques have improved on understanding the change of fuel dimension by describing the atomic-scale processes associated with lattice expansion in the fuels. (author)

  3. Thermal power plants in the Oslofjord district - Recipient evaluations

    International Nuclear Information System (INIS)

    Boehle, B.; Danielssen, D.; Tveite, S.; Haugen, I.; Nilsen, G.; Audunson, T.; Rye, H.; Thendrup, A.

    1975-11-01

    The results presented in a series of reports from the three institutes concerning the physical characteristics of the waters in the vicinoty of five possible sites for thermal (including nuclear) power plants in the Oslofjord district, and the spreading and effects of thermal effluents on the biological state and resources of these waters, are summarised, and an evaluation of the relative suitability of these sites is made. The sites are ranked as follows:- 1. Naverfjorden or, 2. Langangsfjorden - Saga, with effluent release to the Naverfjord region in both cases; 3. Vardeaasen; 4. Hurum; 5; Brenntangen. The possible intake - outlet arrangements are ranked as follows:-1. Deep intake - surface outlet, 2. Deep intake - deep outlet, or surface intake - surface outlet, 3. Surface intake - deep outlet. (JIW)

  4. Fossilization processes in siliceous thermal springs: trends in preservation along thermal gradients

    Science.gov (United States)

    Cady, S. L.; Farmer, J. D.

    1996-01-01

    To enhance our ability to extract palaeobiological and palaeoenvironmental information from ancient thermal spring deposits, we have studied the processes responsible for the development and preservation of stromatolites in modern subaerial thermal spring systems in Yellowstone National Park (USA). We investigated specimens collected from silica-depositing thermal springs along the thermal gradient using petrographic techniques and scanning electron microscopy. Although it is known that thermophilic cyanobacteria control the morphogenesis of thermal spring stromatolites below 73 degrees C, we have found that biofilms which contain filamentous thermophiles contribute to the microstructural development of subaerial geyserites that occur along the inner rims of thermal spring pools and geyser effluents. Biofilms intermittently colonize the surfaces of subaerial geyserites and provide a favoured substrate for opaline silica precipitation. We have also found that the preservation of biotically produced microfabrics of thermal spring sinters reflects dynamic balances between rates of population growth, decomposition of organic matter, silica deposition and early diagenesis. Major trends in preservation of thermophilic organisms along the thermal gradient are defined by differences in the mode of fossilization, including replacement, encrustation and permineralization.

  5. Computer software configuration management plan for 200 East/West Liquid Effluent Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Graf, F.A. Jr.

    1995-02-27

    This computer software management configuration plan covers the control of the software for the monitor and control system that operates the Effluent Treatment Facility and its associated truck load in station and some key aspects of the Liquid Effluent Retention Facility that stores condensate to be processed. Also controlled is the Treated Effluent Disposal System`s pumping stations and monitors waste generator flows in this system as well as the Phase Two Effluent Collection System.

  6. Computer software configuration management plan for 200 East/West Liquid Effluent Facilities

    International Nuclear Information System (INIS)

    Graf, F.A. Jr.

    1995-01-01

    This computer software management configuration plan covers the control of the software for the monitor and control system that operates the Effluent Treatment Facility and its associated truck load in station and some key aspects of the Liquid Effluent Retention Facility that stores condensate to be processed. Also controlled is the Treated Effluent Disposal System's pumping stations and monitors waste generator flows in this system as well as the Phase Two Effluent Collection System

  7. Efficiency Evaluation of Filtration with Fluidized Bed for Treatment of Secondary Effluents for Reuse

    OpenAIRE

    Mohammad Hosaini; Rohallah Moradi; Gholam Hossain Safari

    2013-01-01

    Background & Objectives: Recently, deficient in atmospheric drop and discharges of wastewater effluents leads to serious threat for water resource. For that reason, for prevention of water source pollution and also reuse of wastewater effluents, treatment of such effluents seems to be necessary. Methods: In this work, fluidized bed reactor with a filter was used for treatment of effluents from Shahrak Gharb wastewater treatment plant. Various parameters such as BOD5, COD, TS, TP, TN and t...

  8. In situ and laboratory bioassays to evaluate the impact of effluent discharges on receiving aquatic ecosystems

    International Nuclear Information System (INIS)

    Smolders, R.; Bervoets, L.; Blust, R.

    2004-01-01

    Effluents are a main source of direct and often continuous input of pollutants into aquatic ecosystems with long-term implications on ecosystem functioning. Therefore, the study of the effects of effluent exposure on organisms, populations or communities within the framework of impact assessment has a high ecological relevance. The aim of this study was to assess the toxicological impact of two effluents, one household wastewater treatment effluent (Effluent 1) and one industrial effluent (Effluent 2), on the receiving aquatic ecosystem using two test species under both in situ and laboratory conditions. Zebra mussel (Dreissena polymorpha) and common carp (Cyprinus carpio) were exposed under laboratory conditions in an online monitoring flow-through system (receiving different concentrations of Effluent 2) and under in situ conditions along the pollution gradient established by these two effluent discharges. Bioassays focussed on growth and condition related endpoints (i.e. condition, growth, lipid budget), since these are key functional processes within organisms and populations. Under laboratory conditions, increasing concentrations of the industrial effluent (Effluent 2) had a negative effect on both zebra mussel and carp energy reserves and condition. Under in situ conditions, the same negative impact of Effluent 2 was observed for zebra mussels, while Effluent 1 had no apparent effect on exposed zebra mussels. Carp growth and condition, on the other hand, were significantly increased at the discharge sites of both effluents when compared to the reference site, probably due to differences in food availability. The results indicate that a combination of in situ and laboratory exposures can illustrate how ecological processes influence bioassay studies. The incorporation of indirect, ecological effects, like changes in food availability, provides considerable benefit in understanding and predicting effects of effluents on selected species under realistic exposure

  9. In situ and laboratory bioassays to evaluate the impact of effluent discharges on receiving aquatic ecosystems

    Energy Technology Data Exchange (ETDEWEB)

    Smolders, R. [Laboratory for Ecophysiology, Biochemistry and Toxicology, University of Antwerp (RUCA), Groenenborgerlaan 171, B-2020 Antwerp (Belgium)]. E-mail: roel.smolders@ua.ac.be; Bervoets, L. [Laboratory for Ecophysiology, Biochemistry and Toxicology, University of Antwerp (RUCA), Groenenborgerlaan 171, B-2020 Antwerp (Belgium); Blust, R. [Laboratory for Ecophysiology, Biochemistry and Toxicology, University of Antwerp (RUCA), Groenenborgerlaan 171, B-2020 Antwerp (Belgium)

    2004-11-01

    Effluents are a main source of direct and often continuous input of pollutants into aquatic ecosystems with long-term implications on ecosystem functioning. Therefore, the study of the effects of effluent exposure on organisms, populations or communities within the framework of impact assessment has a high ecological relevance. The aim of this study was to assess the toxicological impact of two effluents, one household wastewater treatment effluent (Effluent 1) and one industrial effluent (Effluent 2), on the receiving aquatic ecosystem using two test species under both in situ and laboratory conditions. Zebra mussel (Dreissena polymorpha) and common carp (Cyprinus carpio) were exposed under laboratory conditions in an online monitoring flow-through system (receiving different concentrations of Effluent 2) and under in situ conditions along the pollution gradient established by these two effluent discharges. Bioassays focussed on growth and condition related endpoints (i.e. condition, growth, lipid budget), since these are key functional processes within organisms and populations. Under laboratory conditions, increasing concentrations of the industrial effluent (Effluent 2) had a negative effect on both zebra mussel and carp energy reserves and condition. Under in situ conditions, the same negative impact of Effluent 2 was observed for zebra mussels, while Effluent 1 had no apparent effect on exposed zebra mussels. Carp growth and condition, on the other hand, were significantly increased at the discharge sites of both effluents when compared to the reference site, probably due to differences in food availability. The results indicate that a combination of in situ and laboratory exposures can illustrate how ecological processes influence bioassay studies. The incorporation of indirect, ecological effects, like changes in food availability, provides considerable benefit in understanding and predicting effects of effluents on selected species under realistic exposure

  10. Bioremediation Kinetics of Pharmaceutical Industrial Effluent

    Directory of Open Access Journals (Sweden)

    M. Šabić

    2015-05-01

    Full Text Available In recent years, concerns about the occurrence and fate of pharmaceuticals that could be present in water and wastewater has gained increasing attention. With the public’s enhanced awareness of eco-safety, environmentally benign methods based on microorganisms have become more accepted methods of removing pollutants from aquatic systems. This study investigates bioremediation of pharmaceutical wastewater from pharmaceutical company Pliva Hrvatska d.o.o., using activated sludge and bioaugmented activated sludge with isolated mixed bacterial culture. The experiments were conducted in a batch reactor in submerged conditions, at initial concentration of organic matter in pharmaceutical wastewater, expressed as COD, 5.01 g dm–3 and different initial concentrations of activated sludge, which ranged from 1.16 to 3.54 g dm–3. During the experiments, the COD, pH, concentrations of dissolved oxygen and biomass were monitored. Microscopic analyses were performed to monitor the quality of activated sludge. Before starting with the bioremediation in the batch reactor, toxicity of the pharmaceutical wastewater was determined by toxicity test using bacteria Vibrio fischeri. The obtained results showed that the effective concentration of the pharmaceutical wastewater was EC50 = 17 % and toxicity impact index was TII50 = 5.9, meaning that the untreated pharmaceutical industrial effluent must not be discharged into the environment before treatment. The results of the pharmaceutical wastewater bioremediation process in the batch reactor are presented in Table 1. The ratio γXv ⁄ γX maintained high values throughout all experiments and ranged from 0.90 and 0.95, suggesting that the concentrations of biomass remained unchanged during the experiments. The important kinetic parameters required for performance of the biological removal process, namely μmax, Ks, Ki, Y and kd were calculated from batch experiments (Table 2. Figs. 1 and 2 show the experimental

  11. Alternatives to disposal of Hanford Site liquid effluents to the soil column

    International Nuclear Information System (INIS)

    Meinhardt, C.C.; Flyckt, D.L.; Wirsing, R.M.; Winterhalder, J.A.

    1987-04-01

    Alternative systems were selected for 28 effluent streams, based on the use of available technology and ability to eliminate the contaminated effluent or reduce contaminant levels to meet specified effluent disposal criteria and standards derived from DOE Orders and environmental statutes. This study determined that technically feasible alternative waste disposal systems are available. 6 refs., 2 figs., 2 tabs

  12. The effects of brewery effluent discharge on the water quality and ...

    African Journals Online (AJOL)

    Effluent discharge into the river significantly altered the water quality. Monitoring of effluent discharge into the aquatic environment and strict adherence to regulatory limits will halt further degradation of the environment. Key words: Water, sediment physico-chemistry, distribution coefficient, effluent discharge, tropical river ...

  13. Caractérisation de deux effluents industriels au Togo :étude d'impact ...

    African Journals Online (AJOL)

    Characterization of two industrial effluents in Togo : environment impact study. Environment pollution due to two industrial effluents has been investigated. Results how that effluent derive from the factory of the treatment of Kpémé posphate ore was loaded with settling suspended matter (> 90 % of total suspended solids).

  14. TOXICITY OF INDUSTRIAL EFFLUENT ON TOTAL CHLOROPHYLL CONTENT OF CERTAIN AQUATIC MACROPHYTES

    OpenAIRE

    Singh Priti; Vishen Ashish; Wadhwani R; Pandey Y.N

    2012-01-01

    To assess the toxicity of industrial effluents on certain macrophytes, the total chlorophyll content of free floating, submerged and emergent macrophytes were estimated in concentrations of industrial effluents at varying exposure duration. The result revealed reduction in total chlorophyll content of exposed macrophytes at higher concentrations of industrial effluents on prolonged duration.

  15. 40 CFR 420.07 - Effluent limitations guidelines and standards for pH.

    Science.gov (United States)

    2010-07-01

    ...) EFFLUENT GUIDELINES AND STANDARDS IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY General Provisions § 420.07 Effluent limitations guidelines and standards for pH. (a) The pH level in process wastewaters... 40 Protection of Environment 28 2010-07-01 2010-07-01 true Effluent limitations guidelines and...

  16. 75 FR 10438 - Effluent Limitations Guidelines and Standards for the Construction and Development Point Source...

    Science.gov (United States)

    2010-03-08

    ... Effluent Limitations Guidelines and Standards for the Construction and Development Point Source Category... technology-based Effluent Limitations Guidelines and New Source Performance Standards for the Construction... technology-based Effluent Limitations Guidelines and New Source Performance Standards for the Construction...

  17. Method and apparatus for treating gaseous effluents from waste treatment systems

    Science.gov (United States)

    Flannery, Philip A.; Kujawa, Stephan T.

    2000-01-01

    Effluents from a waste treatment operation are incinerated and oxidized by passing the gases through an inductively coupled plasmas arc torch. The effluents are transformed into plasma within the torch. At extremely high plasma temperatures, the effluents quickly oxidize. The process results in high temperature oxidation of the gases without addition of any mass flow for introduction of energy.

  18. Thermal Properties and Thermal Analysis:

    Science.gov (United States)

    Kasap, Safa; Tonchev, Dan

    The chapter provides a summary of the fundamental concepts that are needed to understand the heat capacity C P, thermal conductivity κ, and thermal expansion coefficient α L of materials. The C P, κ, and α of various classes of materials, namely, semiconductors, polymers, and glasses, are reviewed, and various typical characteristics are summarized. A key concept in crystalline solids is the Debye theory of the heat capacity, which has been widely used for many decades for calculating the C P of crystals. The thermal properties are interrelated through Grüneisen's theorem. Various useful empirical rules for calculating C P and κ have been used, some of which are summarized. Conventional differential scanning calorimetry (DSC) is a powerful and convenient thermal analysis technique that allows various important physical and chemical transformations, such as the glass transition, crystallization, oxidation, melting etc. to be studied. DSC can also be used to obtain information on the kinetics of the transformations, and some of these thermal analysis techniques are summarized. Temperature-modulated DSC, TMDSC, is a relatively recent innovation in which the sample temperature is ramped slowly and, at the same time, sinusoidally modulated. TMDSC has a number of distinct advantages compared with the conventional DSC since it measures the complex heat capacity. For example, the glass-transition temperature T g measured by TMDSC has almost no dependence on the thermal history, and corresponds to an almost step life change in C P. The new Tzero DSC has an additional thermocouple to calibrate better for thermal lags inherent in the DSC measurement, and allows more accurate thermal analysis.

  19. Prefiltration of gaseous effluents in plant dismantling

    International Nuclear Information System (INIS)

    Pilot, G.; Pourprix, M.

    1991-01-01

    The dismantling techniques and mainly the thermal cutting tools can create large amounts of airbone dust, possibly contaminated in the case of the cutting of radioactive materials. Among the secondary solid emissions, the aerosols constitute the most mobile part which can disseminate contamination in the cell where the cutting operation takes place and in the ventilation ducts up to the HEPA filters. An optimised prefiltration coupled with a captation device at the aerosol generating source allows to avoid the dissemination of the contamination, to increase the life of HEPA filters and thus to reduce the amount of solid wastes. The object in this work was to select one or several cleaning devices, selection that can be done from the knowledge of the physico-chemical characteristics of the gas and aerosols to deal with, the available cleaning devices and the implied facility

  20. Effluent profile of commercially used low-phosphorus fish feeds

    International Nuclear Information System (INIS)

    Sugiura, Shozo H.; Marchant, Daniel D.; Kelsey, Kevin; Wiggins, Thomas; Ferraris, Ronaldo P.

    2006-01-01

    Excess phosphorus (P) in aquaculture feeds contributes to the eutrophication of natural waters. While commercially available low-P (LP) fish feeds have been developed, there is uncertainty about their potential to reduce effluent P while maintaining fish growth relative to regular P (RP) feeds. We therefore simulated commercial aquaculture conditions and fed for 55 days rainbow trout (∼190 kg/raceway, n = 3 raceways/diet) RP (1.4% total P) and LP (1.0%) feeds then determined effluent P levels, fish growth, and feed costs. Excretions of fecal-P and soluble-P, but not particulate-P, in effluents were greater in RP than in LP ponds. Fish growth, bone-P and plasma-P were similar between diets, demonstrating that LP feeds can lower effluent P levels without compromising growth. Costs were $0.97/kg fish production for LP feeds, and $0.74/kg for RP. Because feed is the largest variable cost in commercial aquaculture, the use of LP feeds can significantly increase production costs. - Commercial low-phosphorus fish feeds pollute less but are more costly than standard fish feeds that provide similar fish growth rates

  1. Effect of sewage oxidation pond effluent on macroinvertebrate ...

    African Journals Online (AJOL)

    The influence on aquatic macroinvertebrates of sewage oxidation pond effluent discharge was investigated in a tropical forest stream in Ile-Ife, Nigeria. A total of 858 individual macroinvertebrates were collected. They belong to 8 taxa which represent 5 orders. The number of taxa was low when compared to the findings in ...

  2. ASSESSMENT OF IN VITRO ANDROGENIC ACTIVITY IN KRAFT MILL EFFLUENT

    Science.gov (United States)

    Detection of In Vitro Androgenic Activity in Feedlot Effluent. Lambright, CS 1 , Guillette, LJ, Jr.2, Gray, LE, Jr.1 , 1USEPA, NHEERL, RTP, NC, 2 University of Florida, Dept. of Zoology, Gainesville FLRecent studies have shown the presence of androgenic activity in water...

  3. The Effect of Detergent Effluent on the Physico-Chemical ...

    African Journals Online (AJOL)

    MICHAEL HORSFALL

    abundance of Anabaena and Oscillatoria sp. which are pollution indicator ... negative effect the effluent from the detergent factory has on the stream, thus ... in aquatic ecosystems and represents one of the most .... American Public Health Association (1998). ... (Cyanophyta) in Nigeria coastal waters. The ... South Western.

  4. Biodiesel production from butter factory effluent | Schabort | African ...

    African Journals Online (AJOL)

    The increase in energy demand coupled with the depletion of fossil fuels has increased the need for renewable and sustainable energy sources. Butter waste effluent was identified as a possible feedstock for biodiesel. The effects of the temperature, alcohol to oil molar ratio, catalyst concentration and the reaction time were ...

  5. Bioremediation of chromium in tannery effluent by microbial consortia

    African Journals Online (AJOL)

    Chromium is the most toxic and common among the heavy metal pollutants of industrial effluents. In the present work the chromium remediation ability of Bacillus subtilis, Pseudomonas aeruginosa and Saccharomyces cerevisiae in consortia and in their immobilized forms was studied and their efficiencies were compared.

  6. Evaluation of Genotoxic Effect of Photographic Effluent Using Allium ...

    African Journals Online (AJOL)

    The increased need to keep graphic records of events has led to the use of photography in investigation and surveys and hence increased photographic activities. Toxicological survey of photographic effluents has received little attention in Nigeria, though the constituents have been shown to be very toxic. This study ...

  7. Effect of Industrial Effluent on the Growth of Marine Diatom ...

    African Journals Online (AJOL)

    The marine centric diatom,Chaetoceros simplex (Ostenfeld, 1901) was exposed to five different concentrations of industrial effluent for 96 hrs to investigate the effect on growth. The physico-chemical parameters viz. colour, odour, temperature, salinity, dissolved oxygen, turbidity, pH, alkalinity, hardness, ammonia, nitrite, ...

  8. Water reclamation and effluent retreatment system at Jaduguda

    Energy Technology Data Exchange (ETDEWEB)

    Beri, K K [Uranium Corporation of India Limited, Jaduguda Mines, Singhbhum (India)

    1994-06-01

    Neutralization of uranium mill tailing with lime provided in original flow sheet was not found adequate for effluent quality control within limits particularly as regards to{sup 226}Ra and Mn. The same was being controlled by dilution and hence no water was being reclaimed. In October 1987 the Jaduguda mill was expanded to augment its ore processing capacity from 1000 MT/day to 1340 MT/day. This necessitated extra water requirement, which could have been met only with water reclamation. But this would have resulted in build up of pollutant ions apart from less water available for dilution. Hence a composite scheme was made for water reclamation and treatment of effluent with BaCl{sub 2} to precipitate Ba(Ra)So{sub 4} and with lime to precipitate Mn as hydroxide. This effluent treatment plant was commissioned in May 1990 and is working satisfactorily. The scheme is being further modified and augmented to take care of Narwa mine water and sewage treatment plant effluent. (author).

  9. Effect of Cassava Processing Effluent on Soil Properties, Growth and ...

    African Journals Online (AJOL)

    A study, comprising a survey, greenhouse and field experiments was conducted to examine the effect of Cassava Processing Effluent (CPE) on soil chemical properties, maize growth performances and grain yield. In the survey, soil samples were taken (0-15 and 15 – 30cm) of CPE contaminated and non contaminated ...

  10. Seasonal impact of quarry mining effluent discharge impacted soils ...

    African Journals Online (AJOL)

    This study was designed to assess the impact quarry mining effluent discharge impacted soil on growth parameters and phytochemical constituents of edible vegetables. Three quarry mining sites were used for the study that covered wet and dry seasons. Plant growth such as plant height, leaf area, internodes and plant ...

  11. Impact of upstream industrial effluents on irrigation water quality ...

    African Journals Online (AJOL)

    ADOWIE PERE

    is acidic, thus enhancing leaching and corrosive tendencies of the irrigation ... of heavy metals in the soil indicated contamination from the effluent from the .... well (SAR = 11.1), which contained high pH (pH= 6.65) and high Chloride ion (Cl-of.

  12. Evaluation of Algae from the effluent of Dandot cement company ...

    African Journals Online (AJOL)

    Twenty genera and fifty species of algae have been reported from the effluent water of Dandot Cement Company. They include thirteen genera and thirty five species from Chlorophyceae; three genera and six species from Cyanophyceae and four genera and nine species from Bacillariophyceae. Camera Lucida drawings ...

  13. Radioactive Effluents from Nuclear Power Plants Annual Report 2007

    International Nuclear Information System (INIS)

    2010-01-01

    This report describes radioactive effluents from commercial nuclear power plants (NPPs) in the United States. This information was reported by the licensees for radioactive discharges that occurred in 2007. The report provides information relevant to the potential impact of NPPs on the environment and on public health.

  14. Effects of industrial effluents and fertilizer applications on the growth ...

    African Journals Online (AJOL)

    A field experiment was conducted in south-western Nigeria to determine the effects of different fertilizer applications on the growth performance of sunflower when cultivated in an Alfisols contaminated with effluents from a paints industry. This was with a view to assessing the yield and nutrient quality of harvested sunflower ...

  15. UASB reactor effluent disinfection by ozone and chlorine

    NARCIS (Netherlands)

    Ribeiro da Silvia, G.H.; Bruning, H.; Gerrity, D.; Daniel, L.A.

    2015-01-01

    This research studied the sequential ozone and chlorine process with respect to, the inactivation of indicator bacteria and the formation of ozone disinfection byproducts in sanitary wastewater effluent. The applied ozone doses were 5, 8 and 10 mg.O3.L-1, followed by chlorine doses of 10, 20 and 30

  16. Effluent management practices at the AAEC Research Establishment

    International Nuclear Information System (INIS)

    Khoe, G.

    1978-02-01

    A technical description is given of the facilities and operation of the waste water and liquid waste management system at the Australian Atomic Energy Commission Research Establishment at Lucas Heights. Also described are practices and principles involved in the control and recording of radioactivity in the effluents. (Author)

  17. IMPACT OF PALM OIL MILL EFFLUENT ON THE ACTIVITIES OF ...

    African Journals Online (AJOL)

    PUBLICATIONS1

    This study was carried out to evaluate the effect of palm oil mill effluent (POME) on some anti ... In Nigeria, palm oil production ... crude palm oil produced, 5-7.5 tonnes of water ... inter group comparison using least significant .... York, U.S.A. pp.

  18. Modelling Effluent Assimilative Capacity of Ikpoba River, Benin City ...

    African Journals Online (AJOL)

    The sheer display of reprehensible propensity on the part of public hospitals, abattoirs, breweries and city dwellers at large to discharge untreated waste, debris, scum and, in particular, municipal and industrial effluents into Ikpoba River has morphed into a situation whereby the assimilative capacity of the river has reached ...

  19. Meeting NPDES permit limits for an effluent-dependent stream

    International Nuclear Information System (INIS)

    Payne, W.L.

    1998-01-01

    When the Savannah River Site in Aiken, South Carolina received a National Pollutant Discharge Elimination System permit containing very low copper and toxicity limits for an effluent-dependent stream, an innovative and cost-effective method to meet them was sought. The South Carolina Department of Health and Environmental Control mandated that compliance with the new limits be achieved within three years of the effective date of the permit. SRS personnel studied various regulatory options for complying with the new limits including Water Effect Ratio, use of a Metals Translator, blending with additional effluents, and outfall relocation. Regulatory options were determined to not be feasible because the receiving stream is effluent dependent. Treatment options were studied after it was determined that none of the regulatory pathways were viable. Corrosion inhibitors were evaluated on a full-scale basis with only limited benefits. Ion exchange was promising, but not cost effective for a high flow effluent with a very low concentration of copper. A treatment wetlands, not normally given consideration for the removal of metals, proved to be the most cost effective method studied and is currently under construction

  20. The effect of anaerobic baffled reactor effluent on nitrogen and ...

    African Journals Online (AJOL)

    Leaching of nitrogen and phosphorus from soil columns during application of anaerobic baffled reactor effluent was evaluated. The soils used were from Inanda (Ia), Cartref (Cf), and Sepane (Se) forms, and a silica sand (SS). Each was packed into duplicate columns (103 mm internal diameter; 200 mm length), four each for ...

  1. Environmental impacts of Sheba tannery (Ethiopia) effluents on the ...

    African Journals Online (AJOL)

    total chromium in drinking waters (0.05 mg/L) as opposed to the levels in the upstream waters. The increased concentrations of Cr(VI) in the water samples indicate the possible environmental pollution of the downstream water bodies by the Sheba tannery effluents. In view of the toxicity and related environmental hazards, ...

  2. Rice field for the treatment of pond aquaculture effluents | Wang ...

    African Journals Online (AJOL)

    We conducted an experiment to evaluate the efficiency of rice fields in treating pond aquaculture effluent and its responses to different fertilizer treatments. Four treatments was considered in the experiment: no rice planted as the control (CT); rice planted and no fertilizer input (RE); rice planted and a rate of approximately ...

  3. Multi-year prediction of estrogenicity in municipal wastewater effluents.

    Science.gov (United States)

    Arlos, Maricor J; Parker, Wayne J; Bicudo, José R; Law, Pam; Marjan, Patricija; Andrews, Susan A; Servos, Mark R

    2018-01-01

    In this study, the estrogenicity of two major wastewater treatment plant (WWTP) effluents located in the central reaches of the Grand River watershed in southern Ontario was estimated using population demographics, excretion rates, and treatment plant-specific removals. Due to the lack of data on estrogen concentrations from direct measurements at WWTPs, the treatment efficiencies through the plants were estimated using the information obtained from an effects-directed analysis. The results show that this approach could effectively estimate the estrogenicity of WWTP effluents, both before and after major infrastructure upgrades were made at the Kitchener WWTP. The model was then applied to several possible future scenarios including population growth and river low flow conditions. The scenario analyses showed that post-upgrade operation of the Kitchener WWTP will not release highly estrogenic effluent under the 2041 projected population increase (36%) or summer low flows. Similarly, the Waterloo WWTP treatment operation is also expected to improve once the upgrades have been fully implemented and is expected to effectively treat estrogens even under extreme scenarios of population growth and river flows. The developed model may be employed to support decision making on wastewater management strategies designed for environmental protection, especially on reducing the endocrine effects in fish exposed to WWTP effluents. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Operation and effluent quality of a small rural wastewater treatment ...

    African Journals Online (AJOL)

    The objective of this study was to evaluate the impact of effluent and sludge discharges of an abattoir wastewater treatment plant (WWTP) on the operation of a municipal aerated pond WWTP. Experiments were carried out in Cervera WWTP, located in northeastern Spain, which comprises four ponds operating in series.

  5. Decolorization of laundry effluent by filamentous fungi | Miranda ...

    African Journals Online (AJOL)

    After selecting, the best fungi were subjected to an experimental design and evaluation of the production of the ligninolytics enzymes. Fungi Phanerochaete chrysosporum CCT 1999, Lentinula edodes CCT 4519 and Curvularia lunata UFPEDA 885 reduced 100% the color of the effluent during growth under agitation while ...

  6. Application of the mixture design to decolourise effluent textile ...

    African Journals Online (AJOL)

    Important pollutants in textile effluents are mainly recalcitrant organics, colours, toxicants and inhibitory compounds, surfactants, chlorinated compounds (AOX), pH and salts. An aerobic system using a continuous stirred bed reactor (SBR) was continuously operated at constant temperature and fed with textile wastewater ...

  7. Anaerobic Treatment of Cane Sugar Effluent from Muhoroni Sugar ...

    African Journals Online (AJOL)

    It was therefore concluded that anaerobic treatment, particularly with pH control and seeding shows potential in first stage management of sugar mill wastewater. Keywords: cane sugar mill effluent, anaerobic treatment, batch reactor, waste stabilization ponds. Journal of Civil Engineering Research and Practice Vol.

  8. Consideration of Factors Affecting Strip Effluent PH and Sodium Content

    Energy Technology Data Exchange (ETDEWEB)

    Peters, T. [Savannah River Site (SRS), Aiken, SC (United States)

    2015-07-29

    A number of factors were investigated to determine possible reasons for why the Strip Effluent (SE) can sometimes have higher than expected pH values and/or sodium content, both of which have prescribed limits. All of the factors likely have some impact on the pH values and Na content.

  9. Nile tilapia culture on domestic effluent treated in stabilization ponds.

    Directory of Open Access Journals (Sweden)

    Clovis Matheus Pereira

    2009-03-01

    Full Text Available The performance and filet quality of tilapias (Oreochromis niloticus culture in effluent stabilization lagoons was tested at the densities of 3 fish/m2 (T3, 7 fish/m2 (T2 and 7 fish/m2 in clean water + diet (T1 with 3 repetitions in tanks of 2.57m2 and 0.60m of water column with supplemental aeration. Fish culture in clean water plus diet (T1 presented the highest growth. The higher density T3 (7/m2 compared to T2 (3/m2 did not result in any difference of total production (p > 0.05 but this was compensated by the increased individual fish growth rate at lower density. The conditions that sustain fish survival culture with ETE effluent were attested by the high survival (> 90% under both treatments, but only 10% of the water samples from T2 and T3 N-total ammonium was favorable for fish growth (< 2.0mg/L. The rearing system improved the effluent quality, reducing the total organic nitrogen and the solids in suspension. The faecal coliforms, Salmonella sp. and Staphylococcus aureus from the effluent and fish were verified to be within the standards laid down by the World Health Organization (WHO.

  10. Land Application of Sewage Effluents and Sludges: Selected Abstracts.

    Science.gov (United States)

    Environmental Protection Agency, Washington, DC. Office of Research and Development.

    This report contains 568 selected abstracts concerned with the land application of sewage effluents and sludges. The abstracts are arranged in chronological groupings of ten-year periods from the l940's to the mid-l970's. The report also includes an author index and a subject matter index to facilitate reference to specific abstracts or narrower…

  11. Separation of tritium from gaseous and aqueous effluent systems

    International Nuclear Information System (INIS)

    Kobisk, E.H.

    1977-01-01

    Three processes are discussed for separating tritium from gaseous and aqueous effluent systems: separation in the gas phase using Pd-25 wt percent Ag alloy diffusion membranes; electrolytic separation in the aqueous phase using ''bipolar'' electrodes; and the countercurrent exchange of tritium-containing hydrogen gas with water on catalytic surfaces combined with separation by direct electrolysis

  12. Assessment of the effect of effluent discharge from coffee refineries ...

    African Journals Online (AJOL)

    The ecohydrological quality of water resource of Ethiopia is declining at an alarming rate, resulting in severe environmental degradation. This study finds out the effects of effluent discharge from intensive coffee refineries on river water quality based on physicochemical parameters and benthos assemblages as biological ...

  13. Prediction of the mixing length in effluent transport in rivers

    International Nuclear Information System (INIS)

    Szpilowski, S.

    1983-01-01

    Studies have been performed on estimating the transverse mixing length of effluents discharged into rivers. The proposed method is based on measured values of the dispersion coefficient. Field investigations were carried out in the River Vistula in the Warsaw area using radiotracer methods. The procedure can be used for predicting the mixing length in designing sewage systems. (author)

  14. Radioactive Effluents from Nuclear Power Plants Annual Report 2008

    International Nuclear Information System (INIS)

    2010-01-01

    This report describes radioactive effluents from commercial nuclear power plants (NPPs) in the United States. This information was reported by the licensees for radioactive discharges that occurred in 2008. The report provides information relevant to the potential impact of NPPs on the environment and on public health.

  15. Optimizing liquid effluent monitoring at a large nuclear complex.

    Science.gov (United States)

    Chou, Charissa J; Barnett, D Brent; Johnson, Vernon G; Olson, Phil M

    2003-12-01

    Effluent monitoring typically requires a large number of analytes and samples during the initial or startup phase of a facility. Once a baseline is established, the analyte list and sampling frequency may be reduced. Although there is a large body of literature relevant to the initial design, few, if any, published papers exist on updating established effluent monitoring programs. This paper statistically evaluates four years of baseline data to optimize the liquid effluent monitoring efficiency of a centralized waste treatment and disposal facility at a large defense nuclear complex. Specific objectives were to: (1) assess temporal variability in analyte concentrations, (2) determine operational factors contributing to waste stream variability, (3) assess the probability of exceeding permit limits, and (4) streamline the sampling and analysis regime. Results indicated that the probability of exceeding permit limits was one in a million under normal facility operating conditions, sampling frequency could be reduced, and several analytes could be eliminated. Furthermore, indicators such as gross alpha and gross beta measurements could be used in lieu of more expensive specific isotopic analyses (radium, cesium-137, and strontium-90) for routine monitoring. Study results were used by the state regulatory agency to modify monitoring requirements for a new discharge permit, resulting in an annual cost savings of US dollars 223,000. This case study demonstrates that statistical evaluation of effluent contaminant variability coupled with process knowledge can help plant managers and regulators streamline analyte lists and sampling frequencies based on detection history and environmental risk.

  16. Biodegradation Potentials of Cassava Mill Effluent (CME) by ...

    African Journals Online (AJOL)

    Bacillus, Pseudomonas, Aspergillus and Penicillium species which had the highest turbidity were used for bioremediation studies. The consortium of microorganisms demonstrated the highest efficacy. Bioremediation of cassava mill effluent by these microorganisms was manifested in the reduction of biological oxygen ...

  17. 200 area effluent treatment facility opertaional test report

    International Nuclear Information System (INIS)

    Crane, A.F.

    1995-01-01

    This document reports the results of the 200 Area Effluent Treatment Facility (200 Area ETF) operational testing activities. These Operational testing activities demonstrated that the functional, operational and design requirements of the 200 Area ETF have been met and identified open items which require retesting

  18. An evaluation of the whole effluent toxicity test method

    International Nuclear Information System (INIS)

    Osteen, D.V.

    1999-01-01

    Whole effluent toxicity (WET) testing has become increasingly more important to the Environmental Protection Agency (EPA) and the States in the permitting of wastewater discharges from industry and municipalities. The primary purpose of the WET test is to protect aquatic life by predicting the effect of an effluent on the receiving stream. However, there are both scientific and regulatory concerns that using WET tests to regulate industrial effluents may result in either false positives and/or false negatives. In order to realistically predict the effect of an effluent on the receiving stream, the test should be as representative as possible of the conditions in the receiving stream. Studies (Rand and Petrocelli 1985) suggested several criteria for an ideal aquatic toxicity test organism, one of which is that the organism be indigenous to, or representative of, the ecosystem receiving the effluent. The other component needed in the development of a predictive test is the use of the receiving stream water or similar synthetic water as the control and dilution water in the test method. Use of an indigenous species and receiving water in the test should help reduce the variability in the method and allow the test to predict the effect of the effluent on the receiving stream. The experience with toxicity testing at the Savannah River Site (SRS) has yielded inconclusive data because of the inconsistency and unreliability of the results. The SRS contention is that the WET method in its present form does not adequately mimic actual biological/chemical conditions of the receiving streams and is neither reasonable nor accurate. This paper discusses the rationale for such a position by SRS on toxicity testing in terms of historical permitting requirements, outfall effluent test results, standard test method evaluation, scientific review of alternate test species, and concerns over the test method expressed by other organizations. This paper presents the Savannah River Site

  19. Improving methane production from digested manure biofibers by mechanical and thermal alkaline pretreatment

    DEFF Research Database (Denmark)

    Tsapekos, Panagiotis; Kougias, Panagiotis; Frison, A.

    2016-01-01

    the effluent stream of biogas reactors. Batch and continuous experiments were conducted to evaluate the efficiency of these pretreatments. In batch experiments, the mechanical pretreatment improved the degradability up to 45%. Even higher efficiency was shown by applying thermal alkaline pretreatments...

  20. Meso-meteorological effect of thermal releases from nuclear power plants in the GW range

    International Nuclear Information System (INIS)

    Bahloul, C.; Le Berre, P.

    1975-01-01

    A comparison is made between the energy released by nuclear power plants into the environment and the energy brought into action by meso-meteorological phenomena. Observations on the occasion of important heat release (forest fires) are made and compared with the thermal effluents generated by nuclear power plants [fr

  1. Biogas Production From Cassava Starch Effluent Using Microalgae As Biostabilisator

    Directory of Open Access Journals (Sweden)

    B. Budiyono

    2011-07-01

    Full Text Available The rapid growing of Indonesian population is emerging several critical national issues i.e. energy, food, environmental, water, transportation, as well as law and human right. As an agricultural country, Indonesia has abundant of biomass wastes such as agricultural wastes include the cassava starch wastes. The problem is that the effluent from cassava starch factories is released directly into the river before properly treatment. It has been a great source of pollution and has caused environmental problems to the nearby rural population. The possible alternative to solve the problem is by converting waste to energy biogas in the biodigester. The main problem of the biogas production of cassava starch effluent is acid forming-bacteria quickly produced acid resulting significantly in declining pH below the neutral pH and diminishing growth of methane bacteria. Hence, the only one of the method to cover this problem is by adding microalgae as biostabilisator of pH. Microalgae can also be used as purifier agent to absorb CO2.The general objective of this research project was to develop an integrated process of biogas production and purification from cassava starch effluent by using biostabilisator agent microalgae. This study has been focused on the used of urea, ruminant, yeast, microalgae, the treatment of gelled and ungelled feed for biogas production, pH control during biogas production using buffer Na2CO3, and feeding management in the semi-continuous process of biogas production. The result can be concluded as follows: i The biogas production increased after cassava starch effluent and yeast was added, ii Biogas production with microalgae and cassava starch effluent, yeast, ruminant bacteria, and urea were 726.43 ml/g total solid, iii Biogas production without  microalgae was 189 ml/g total solid.

  2. Effluent and environmental monitoring of Chalk River Laboratories

    Energy Technology Data Exchange (ETDEWEB)

    Pilgrim, T.; De Waele, C.; Gallagher, C. [Atomic Energy of Canada Limited, Chalk River, ON (Canada)

    2014-07-01

    Atomic Energy of Canada Limited's (AECL's) Environmental Protection Program has been gathering environmental monitoring data at its Chalk River Laboratories (CRL) for over 60 years. The comprehensive effluent and environmental monitoring program at CRL consists of more than 600 sampling locations, including the Ottawa River, with approximately 60,000 analyses performed on air and liquid effluent parameters each year. Monitoring for a variety of radiological and non-radiological parameters is regularly conducted on various media, including ambient air, foodstuff (e.g. milk, fish, garden produce, large game, and farm animals), groundwater, Ottawa River water and other surface water on and off-site. The purpose of the monitoring program is to verify that past and current radiological and non-radiological emissions derived from AECL operations and activities, such as process water effluent into the Ottawa River, are below regulatory limits and demonstrate that CRL operations do not negatively affect the quality of water on or leaving the site. In fact, ongoing program reports demonstrate that radiological emissions are well below regulatory limits and have been declining for the past five years, and that non-radiological contaminants do not negatively affect the quality of water on and off the site. Two updated Canadian Standards Association (CSA) standards for Effluent and Environmental monitoring have come into effect and have resulted in some changes to the AECL Program. This presentation will discuss effluent and surface water monitoring results, the observed trends, the changes triggered by the CSA standards, and a path forward for the future. (author)

  3. Two stage treatment of dairy effluent using immobilized Chlorella pyrenoidosa

    Science.gov (United States)

    2013-01-01

    Background Dairy effluents contains high organic load and unscrupulous discharge of these effluents into aquatic bodies is a matter of serious concern besides deteriorating their water quality. Whilst physico-chemical treatment is the common mode of treatment, immobilized microalgae can be potentially employed to treat high organic content which offer numerous benefits along with waste water treatment. Methods A novel low cost two stage treatment was employed for the complete treatment of dairy effluent. The first stage consists of treating the diary effluent in a photobioreactor (1 L) using immobilized Chlorella pyrenoidosa while the second stage involves a two column sand bed filtration technique. Results Whilst NH4+-N was completely removed, a 98% removal of PO43--P was achieved within 96 h of two stage purification processes. The filtrate was tested for toxicity and no mortality was observed in the zebra fish which was used as a model at the end of 96 h bioassay. Moreover, a significant decrease in biological oxygen demand and chemical oxygen demand was achieved by this novel method. Also the biomass separated was tested as a biofertilizer to the rice seeds and a 30% increase in terms of length of root and shoot was observed after the addition of biomass to the rice plants. Conclusions We conclude that the two stage treatment of dairy effluent is highly effective in removal of BOD and COD besides nutrients like nitrates and phosphates. The treatment also helps in discharging treated waste water safely into the receiving water bodies since it is non toxic for aquatic life. Further, the algal biomass separated after first stage of treatment was highly capable of increasing the growth of rice plants because of nitrogen fixation ability of the green alga and offers a great potential as a biofertilizer. PMID:24355316

  4. Thermal comfort

    DEFF Research Database (Denmark)

    d’Ambrosio Alfano, Francesca Romana; Olesen, Bjarne W.; Palella, Boris Igor

    2014-01-01

    Thermal comfort is one of the most important aspects of the indoor environmental quality due to its effects on well-being, people's performance and building energy requirements. Its attainment is not an easy task requiring advanced design and operation of building and HVAC systems, taking...... into account all parameters involved. Even though thermal comfort fundamentals are consolidated topics for more than forty years, often designers seem to ignore or apply them in a wrong way. Design input values from standards are often considered as universal values rather than recommended values to be used...... under specific conditions. At operation level, only few variables are taken into account with unpredictable effects on the assessment of comfort indices. In this paper, the main criteria for the design and assessment of thermal comfort are discussed in order to help building and HVAC systems designers...

  5. Facility effluent monitoring plan for the 284-E and 284-W power plants

    International Nuclear Information System (INIS)

    Nickels, J.M.; Herman, D.R.

    1992-11-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. A facility effluent monitoring plan determination was performed during calendar year 1991 and the evaluation requires the need for a facility effluent monitoring plan. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements

  6. Offsite dose calculation manual guidance: Standard radiological effluent controls for boiling water reactors

    International Nuclear Information System (INIS)

    Meinke, W.W.; Essig, T.H.

    1991-04-01

    This report contains guidance which may be voluntarily used by licensees who choose to implement the provision of Generic Letter 89-- 01, which allows Radiological Effluent Technical Specifications (RETS) to be removed from the main body of the Technical Specifications and placed in the Offsite Dose Calculation Manual (ODCM). Guidance is provided for Standard Effluent Controls definitions, Controls for effluent monitoring instrumentation, Controls for effluent releases, Controls for radiological environmental monitoring, and the basis for Controls. Guidance on the formulation of RETS has been available in draft form for a number of years; the current effort simply recasts those RETS into Standard Radiological Effluent Controls for application to the ODCM. 11 tabs

  7. The effect of advanced treatment of sewage effluents on metal speciation and (bio)availability.

    Science.gov (United States)

    Peters, A; Merrington, G; Leverett, D; Ellor, B; Lofts, S; Gravell, A

    2014-02-01

    The bioavailability of metals can be strongly influenced by dissolved organic carbon (DOC). Wastewater treatment effluents add considerable quantities of DOC and metals to receiving waters, and as effluent controls become more stringent advanced effluent treatments may be needed. We assessed the effects of two types of advanced treatment processes on metal availability in wastewater effluents. Trace metal availability was assessed using diffuse gradients in thin films and predicted through speciation modelling. The results show little difference in metal availability post-advanced treatment. EDTA-like compounds are important metal complexants in the effluents.

  8. Matrix thermalization

    International Nuclear Information System (INIS)

    Craps, Ben; Evnin, Oleg; Nguyen, Kévin

    2017-01-01

    Matrix quantum mechanics offers an attractive environment for discussing gravitational holography, in which both sides of the holographic duality are well-defined. Similarly to higher-dimensional implementations of holography, collapsing shell solutions in the gravitational bulk correspond in this setting to thermalization processes in the dual quantum mechanical theory. We construct an explicit, fully nonlinear supergravity solution describing a generic collapsing dilaton shell, specify the holographic renormalization prescriptions necessary for computing the relevant boundary observables, and apply them to evaluating thermalizing two-point correlation functions in the dual matrix theory.

  9. Matrix thermalization

    Science.gov (United States)

    Craps, Ben; Evnin, Oleg; Nguyen, Kévin

    2017-02-01

    Matrix quantum mechanics offers an attractive environment for discussing gravitational holography, in which both sides of the holographic duality are well-defined. Similarly to higher-dimensional implementations of holography, collapsing shell solutions in the gravitational bulk correspond in this setting to thermalization processes in the dual quantum mechanical theory. We construct an explicit, fully nonlinear supergravity solution describing a generic collapsing dilaton shell, specify the holographic renormalization prescriptions necessary for computing the relevant boundary observables, and apply them to evaluating thermalizing two-point correlation functions in the dual matrix theory.

  10. Matrix thermalization

    Energy Technology Data Exchange (ETDEWEB)

    Craps, Ben [Theoretische Natuurkunde, Vrije Universiteit Brussel (VUB), and International Solvay Institutes, Pleinlaan 2, B-1050 Brussels (Belgium); Evnin, Oleg [Department of Physics, Faculty of Science, Chulalongkorn University, Thanon Phayathai, Pathumwan, Bangkok 10330 (Thailand); Theoretische Natuurkunde, Vrije Universiteit Brussel (VUB), and International Solvay Institutes, Pleinlaan 2, B-1050 Brussels (Belgium); Nguyen, Kévin [Theoretische Natuurkunde, Vrije Universiteit Brussel (VUB), and International Solvay Institutes, Pleinlaan 2, B-1050 Brussels (Belgium)

    2017-02-08

    Matrix quantum mechanics offers an attractive environment for discussing gravitational holography, in which both sides of the holographic duality are well-defined. Similarly to higher-dimensional implementations of holography, collapsing shell solutions in the gravitational bulk correspond in this setting to thermalization processes in the dual quantum mechanical theory. We construct an explicit, fully nonlinear supergravity solution describing a generic collapsing dilaton shell, specify the holographic renormalization prescriptions necessary for computing the relevant boundary observables, and apply them to evaluating thermalizing two-point correlation functions in the dual matrix theory.

  11. 40 CFR 455.63 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... control technology (BCT). 455.63 Section 455.63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... application of the best conventional pollution control technology: There shall be no discharge of process... effluent reduction attainable by the application of the best conventional pollutant control technology (BCT...

  12. 40 CFR 469.19 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Science.gov (United States)

    2010-07-01

    ... technology (BCT). 469.19 Section 469.19 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... application of the best conventional pollution control technology (BCT). Except as provided in 40 CFR 125.30... conventional pollution control technology (BCT): Subpart A—Semiconductor BCT Effluent Limitations Pollutant or...

  13. 40 CFR 424.27 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... control technology. 424.27 Section 424.27 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Furnaces and Other Smelting Operations With Wet Air Pollution Control Devices Subcategory § 424.27 Effluent... conventional pollutant control technology. Except as provided in §§ 125.30 through 125.32, any existing point...

  14. 40 CFR 424.42 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... technology currently available. 424.42 Section 424.42 Protection of Environment ENVIRONMENTAL PROTECTION... Covered Calcium Carbide Furnaces With Wet Air Pollution Control Devices Subcategory § 424.42 Effluent... practicable control technology currently available. Except as provided in §§ 125.30 through 125.32, and...

  15. 40 CFR 424.12 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... technology currently available. 424.12 Section 424.12 Protection of Environment ENVIRONMENTAL PROTECTION... Electric Furnaces With Wet Air Pollution Control Devices Subcategory § 424.12 Effluent limitations... practicable control technology currently available. Except as provided in §§ 125.30 through 125.32, and...

  16. 40 CFR 424.47 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... control technology. 424.47 Section 424.47 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Carbide Furnaces With Wet Air Pollution Control Devices Subcategory § 424.47 Effluent limitations... conventional pollutant control technology. Except as provided in §§ 125.30 through 125.32, any existing point...

  17. 40 CFR 424.17 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... control technology. 424.17 Section 424.17 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Furnaces With Wet Air Pollution Control Devices Subcategory § 424.17 Effluent limitations guidelines... control technology. Except as provided in §§ 125.30 through 125.32, any existing point source subject to...

  18. 40 CFR 415.642 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... SOURCE CATEGORY Cadmium Pigments and Salts Production Subcategory § 415.642 Effluent limitations....32 any existing point source subject to this subpart and producing cadmium pigments must achieve the... of the best practicable control technology currently available (BPT). Subpart BL—Cadmium Pigments...

  19. 40 CFR 445.13 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Science.gov (United States)

    2010-07-01

    ... limitations which represent the application of BAT: Limitations for ammonia (as N), a-terpineol, aniline... degree of effluent reduction attainable by the application of best available technology economically... application of best available technology economically achievable (BAT). Except as provided in 40 CFR 125.30...

  20. 40 CFR 436.32 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... Construction Sand and Gravel Subcategory § 436.32 Effluent limitations guidelines representing the degree of... unaltered by man's activities, is or would be less than 6.0 and water quality criteria in water quality... adjusted downward to the pH water quality criterion for the receiving waters. In no case shall a pH...

  1. 40 CFR 428.33 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS RUBBER MANUFACTURING POINT SOURCE CATEGORY Solution Crumb...) English units (lb/1,000 lb of product) COD 3.12 2.08 BOD5 0.12 .08 TSS 0.24 .16 Oil and grease 0.12 .08 pH...

  2. 40 CFR 428.32 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS RUBBER MANUFACTURING POINT SOURCE CATEGORY Solution...) (1) English units (lb/1,000 lb of product) COD 5.91 3.94 BOD5 0.60 .40 TSS 0.98 .65 Oil and grease 0...

  3. 40 CFR 463.22 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS PLASTICS MOLDING AND FORMING POINT SOURCE CATEGORY... currently available, which are calculated by multiplying the average process water usage flow rate for the... average process water usage flow rate for the cleaning water processes from the permittee. ...

  4. 40 CFR 463.17 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS PLASTICS MOLDING AND FORMING POINT SOURCE CATEGORY Contact... technology, which are calculated by multiplying the average process water usage flow rate for the contact... usage flow rate for the contact cooling and heating water processes from the permittee. ...

  5. 40 CFR 463.12 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS PLASTICS MOLDING AND FORMING POINT SOURCE CATEGORY... technology currently available, which are calculated by multiplying the average process water usage flow rate... process water usage flow rate for the contact cooling and heating water processes from the permittee. ...

  6. 40 CFR 463.32 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS PLASTICS MOLDING AND FORMING POINT SOURCE CATEGORY... currently available, which are calculated by multiplying the average process water usage flow rate for the... of 6.0 to 9.0 at all times. The permit authority will obtain the average process water usage flow...

  7. 40 CFR 440.103 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS ORE MINING AND DRESSING POINT SOURCE CATEGORY Copper, Lead... copper, lead, zinc, gold, silver, or molybdenum bearing ores or any combination of these ores from open... pollutants discharged from mills that use the froth-flotation process alone, or in conjunction with other...

  8. 40 CFR 440.102 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Science.gov (United States)

    2010-07-01

    ...) EFFLUENT GUIDELINES AND STANDARDS ORE MINING AND DRESSING POINT SOURCE CATEGORY Copper, Lead, Zinc, Gold... obtain copper bearing ores, lead bearing ores, zinc bearing ores, gold bearing ores, or silver bearing... which employ the froth flotation process alone or in conjunction with other processes, for the...

  9. 40 CFR 417.152 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... available (BPT): (a) For normal operation of spray drying towers as defined above, the following values... operation of a spray drying tower, but only when a high rate of wet scrubbing is in operation which produces... CATEGORY Manufacture of Spray Dried Detergents Subcategory § 417.152 Effluent limitations guidelines...

  10. 40 CFR 421.142 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS NONFERROUS METALS MANUFACTURING POINT SOURCE... contained in sodium antimonate product Antimony 44.840 20.000 Arsenic 32.650 14.530 Mercury 3.906 1.562... Maximum for any 1 day Maximum for monthly average mg/kg (pounds per million pounds) of antimony metal...

  11. 40 CFR 421.143 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY Primary... sodium antimonate product Antimony 30.150 13.440 Arsenic 21.720 9.687 Mercury 2.344 0.937 (b) Fouled... any 1 day Maximum for monthly average mg/kg pounds per million pounds of antimony metal produced by...

  12. 40 CFR 426.122 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... Incandescent Lamp Envelope Manufacturing Subcategory § 426.122 Effluent limitations guidelines representing the...): (a) Any manufacturing plant which produces incandescent lamp envelopes shall meet the following... any 1 day Average of daily values for 30 consecutive days shall not exceed— Metric units (g/kkg of...

  13. 40 CFR 440.13 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Science.gov (United States)

    2010-07-01

    ... water equal to the difference between annual precipitation falling on the treatment facility and the... pollutants discharged in mine drainage from mines operated to obtain iron ore shall not exceed: Effluent.... (2) In the event that the annual precipitation falling on the treatment facility and the drainage...

  14. 40 CFR 421.222 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... day Maximum for monthly average mg/kg (pounds per million pounds) of technical grade molybdenum plus... AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS NONFERROUS METALS MANUFACTURING POINT SOURCE... technology currently available. Except as provided in 40 CFR 125.30 through 125.32, any existing point source...

  15. 40 CFR 421.323 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ....885 Nickel 3.503 2.357 Fluoride 222.900 126.700 (d) Digestion wet air pollution control. BAT... denitration wet air pollution control. BAT Limitations for the Secondary Uranium Subcategory Pollutant or... representing the degree of effluent reduction attainable by the application of the best available technology...

  16. 40 CFR 471.102 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Science.gov (United States)

    2010-07-01

    ... treatment wet air pollution control scrubber blowdown. Subpart J—BAT Pollutant or pollutant property Maximum...) Mixing wet air pollution control scrubber blowdown. Subpart J—BAT Pollutant or pollutant property Maximum... degree of effluent reduction attainable by the application of the best available technology economically...

  17. 40 CFR 421.223 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ...) Vanadium decomposition wet air pollution control. BAT Limitations for the Secondary Molybdenum and Vanadium... (d) Molybdenum drying wet air pollution control. BAT Limitations for the Secondary Molybdenum and... representing the degree of effluent reduction attainable by the application of the best available technology...

  18. Production methods for decreasing nitrous oxide effluents during solid fuel combustion

    Energy Technology Data Exchange (ETDEWEB)

    Kotler, V.R.

    1981-01-01

    The atmosphere can be protected from toxic NO /SUB x/ effluents during fuel combustion in boilers by reducing the amount of NO /SUB x/ during combustion or by cleaning the smoky gases after they leave the boiler. The second method results from the need to process a large amount of smoky gases with a relatively low concentration of nitrous oxide which is chemically resistant and which is not highly soluble in water. The problem is complicated by the SO /SUB x/ , O/sub 2/ and solid particles in the smoky gaes. The method for cleaning smoky gases is complicated and requires mator capital investments and operating expenses. Laboratory tests in the F. E. Dzerzhinskiy Heat Engineering Institute showed that thermal NO /SUB x/ is formed at combustion temperatures above 1550/sup 0/C, and that the concentration of O/sub 2/ has a significant impact on NO /SUB x/ formation, while temperature has much less effect. On the basis of laboratory and industrial tests, the Institute recommended a method to reduce NO /SUB x/ effluents from large boilers: for Kansk-Achinski coals -- low-temperature combustion. The temperature in the combustion nucleus is maintained at 1290/sup 0/C by using a set of measures individual dust systems with direct intection, grinder-blowers, fuel drying and recirculation of about 20% of the smoky gases with the primary air, tangential direct flow burners in several rows along the top). The effectiveness of this system has been checked on a PK-10Sh boiler at the Krasnoyarsk Thermal Power Plant No. 1 and a BK3-210-140 boiler at the Vladivostok Thermal Power Plant No. 2. Further reduction of NO /SUB x/ (by about 20%) requires redistribution of the secondary air along the row of burners. These measures are suggested for use on the P-67 boiler of the 800 MW unit of the Berezovsk State Regional Power Station No. 1. A brief summary of the design and operating measures are provided.

  19. Contribution to immersed arc plasma study: applications to organic aqueous effluent decontamination and gasification

    International Nuclear Information System (INIS)

    Boudesocque, N.

    2007-07-01

    This work is concerned with decontamination and gasification of aqueous organic liquid waste by immersed thermal plasma technology. In this concept, the organic compounds are decomposed into gas by high temperature plasma. A quench of about 107-108 K/s, is obtained by immersion into a given effluent. Two kinds of arc plasma are studied. The first one is an immersed electrical arc stricken between two graphite electrodes. The second one is a plasma jet generated by a non-transferred plasma torch. For dilute liquid waste (1 g/L) containing molecules incompatible with conventional biological processes, the hydroxyl radicals (OH 0 ) are continuously produced by the plasma jet directly into the solution allowing complete molecule mineralization into carbon dioxide and water. The hetero-atoms, if present, are converted into solvated ions. The decomposition of the molecules, such as chloro-phenols and aniline, are studied. Considering the identified intermediate products, a reaction mechanism is proposed. For each tested molecules, their concentration decreased at least of 90 percent. Based on the 'gasosiphon' phenomenon, the experimental reactor insures the simultaneous recirculation of both gas and liquid phases. The hydrodynamic was studied using in situ high frequency imaging technology. A CFD code was applied for numerical simulation of the observed recirculation phenomena. The results were compared with obtained experimental data. In the case of concentrated liquid waste (≥ 100 g/L), syngas was produced by thermal cracking of organic molecules. The best measured composition of the gas is about 45% v/v of H 2 and 45 % v/v of CO when an electrical arc is used. The usability of both studied plasma types were investigated in this field. The experimental study was carried on using fructose and glucose solution (several hundreds g/L) as surrogated effluent. With a specific injection method, gasification rate is about 30 % with one way. Optical Emission Spectroscopy and

  20. Performance Evaluation on Otto Engine Generator Using Gasoline and Biogas from Palm Oil Mill Effluent

    Science.gov (United States)

    Irvan; Trisakti, B.; Husaini, T.; Sitio, A.; Sitorus, TB

    2017-06-01

    Biogas is a flammable gas produced from the fermentation of organic materials by anaerobic bacteria originating from household waste manure and organic waste including palm oil mill effluent (POME). POME is mainly discharged from the sterilization unit of palm oil processing into crude palm oil. This study utilized biogas produced from liquid waste palm oil for use as fuel in the Otto engine generator 4 - stroke, type STARKE GFH1900LX with a peak power of 1.3 kW, 1.0 kW average power, bore 55 mm, stroke 40 mm, Vd 95 × 10-6 m3, Vc 10 × 10-6 m3, compression ratio of 10.5 : 1, and the number of cylinders = 1. The objective of this study is to evaluate the performance of Otto engine generator fueled with biogas that generated from POME, then comparing its performance fueled by gasoline. The performance included power, torque, specific fuel consumption, thermal efficiency, and the air-fuel ratio. Experiment was conducted by using a variation of the lamp load of 100, 200, 300, 400, and 500 W. The results revealed that the use of biogas as fuel decreased in power, torque, brake thermal efficiency, and air fuel ratio (AFR), while there is an increasing of value specific fuel consumption (SFC).