WorldWideScience

Sample records for therapeutic plasma exchange

  1. automated (centrifugal) therapeutic plasma exchange option for ...

    African Journals Online (AJOL)

    Therapeutic plasma exchange (TPE) is performed frequently and effectively in developed countries, whereas the reverse is the case in developing countries. Guillain‑Barre syndrome (GBS), synonymous with acute inflammatory demyelinating polyneuropathy, is an important indication for TPE, but this is rarely administered ...

  2. Therapeutic Plasma Exchange in Critically Ill Children Requiring Intensive Care.

    Science.gov (United States)

    Cortina, Gerard; McRae, Rosemary; Chiletti, Roberto; Butt, Warwick

    2018-02-01

    To characterize the clinical indications, procedural safety, and outcome of critically ill children requiring therapeutic plasma exchange. Retrospective observational study based on a prospective registry. Tertiary and quaternary referral 30-bed PICU. Forty-eight critically ill children who received therapeutic plasma exchange during an 8-year period (2007-2014) were included in the study. Therapeutic plasma exchange. A total of 48 patients underwent 244 therapeutic plasma exchange sessions. Of those, therapeutic plasma exchange was performed as sole procedure in 193 (79%), in combination with continuous renal replacement therapy in 40 (16.4%) and additional extracorporeal membrane oxygenation in 11 (4.6%) sessions. The most common admission diagnoses were hematologic disorders (30%), solid organ transplantation (20%), neurologic disorders (20%), and rheumatologic disorders (15%). Complications associated with the procedure occurred in 50 (21.2%) therapeutic plasma exchange sessions. Overall, patient survival from ICU was 82%. Although patients requiring therapeutic plasma exchange alone (n = 31; 64%) had a survival rate of 97%, those with additional continuous renal replacement therapy (n = 13; 27%) and extracorporeal membrane oxygenation (n = 4; 8%) had survival rates of 69% and 50%, respectively. Factors associated with increased mortality were lower Pediatric Index of Mortality 2 score, need for mechanical ventilation, higher number of failed organs, and longer ICU stay. Our results indicate that, in specialized centers, therapeutic plasma exchange can be performed relatively safely in critically ill children, alone or in combination with continuous renal replacement therapy and extracorporeal membrane oxygenation. Outcome in children requiring therapeutic plasma exchange alone is excellent. However, survival decreases with the number of failed organs and the need for continuous renal replacement therapy and extracorporeal membrane oxygenation.

  3. Therapeutic plasma exchange in a single center: Ibni Sina experience.

    Science.gov (United States)

    Arslan, Onder; Arat, Mutlu; Tek, Ibrahim; Ayyildiz, Erol; Ilhan, Osman

    2004-06-01

    The number of therapeutic procedures is increasing steadily year by year with growing collaboration of departments other than Hematology. In the aim to demonstrate our single center activity we analyzed our data since four years. Between years 1998 and 2001, 658 therapeutic plasma exchange (TPE) procedures were performed on 158 patients. Median age and male/female ratio were 37 (range, 15-87) and 80/78, respectively. Main indications were myastenia gravis (n=55, 34%), TTP (n=13, 8.5%), post ABO mismatched allogeneic hematopoietic cell transplantation aregeneratoric anemia (n=6, 7.5%), progressive systemic sclerosis (n=10, 6.5%), multiple myeloma (n=10, 6.5%), Gullian Barre Syndrome (n=9, 5.9%), multiple sclerosis (n=7, 4.6%), Waldenström Macroglobulinemia (n=5, 3.4%), polymyositis (n=4, 2.7%), sepsis and disseminated intravascular coagulation (n=4, 2.7%). Departments who referred the majority of the patients for TPE were neurology (n=199), hematology (n=153), immunology (n=78), intensive care unit (n=78) and thorax surgery (n=51). The median TPE procedure per patient was 4 (range, 1-50). All the procedures were performed on continuous flow cell separators and median plasma volume processed per cycle was 2471 ml (range 436-5000). The replacement fluids used were 3% hydroxyethylstarch (HES) (24%), 5% albumin (35%), fresh frozen plasma (25%), and HES and albumin (16%). HES was tolerated well even as a sole replacement fluid with acceptable minor side effects. In three patients with progressing hypoalbuminemia HES was replaced or combined with 5% albumin. Close monitoring of serum albumin and fibrinogen levels after repeated procedures is mandatory. In our four years of TPE experience we have increased our collaboration with other departments. 3% HES+/-5% Albumin is a feasible, well tolerated and cost effective replacement fluid combination especially for short-term plasma exchange therapy.

  4. Therapeutic Plasma Exchange Option for Guillain-Barre Syndrome

    African Journals Online (AJOL)

    2018-02-07

    Feb 7, 2018 ... [1] It is an immune-mediated inflammatory disease affecting the myelin and .... blood pressure (140/100 mmHg), and respiratory rate ... Renal function test and serum protein results showed no significant abnormality. Certain other ..... cell exchange (Erythrocytapheresis) in Nigeria for a sickle cell anaemia ...

  5. Pharmacokinetic profile of voriconazole in a critically ill patient on therapeutic plasma exchange

    NARCIS (Netherlands)

    Spriet, I.; Bruggemann, R.J.M.; Annaert, P.; Meersseman, P.; Wijngaerden, E. van; Lagrou, K.; Willems, L.

    2013-01-01

    BACKGROUND: Extracorporeal removal of drugs during therapeutic plasma exchange (TPE) can lead to decreased efficacy, as shown in several reports discussing altered pharmacokinetics (PKs) of antibiotics during TPE. In particular, drugs with a low volume of distribution or a high protein binding are

  6. Plasma extraction rate and collection efficiency during therapeutic plasma exchange with Spectra Optia in comparison with Haemonetics MCS+.

    Science.gov (United States)

    Lambert, Catherine; Gericke, Marion; Smith, Richard; Hermans, Cedric

    2011-01-01

    For therapeutic plasma exchange (TPE), continuous and intermittent flow separators are known to be efficient. This study was undertaken to compare the performances of the Spectra Optia, a continuous flow centrifugal apheresis system recently developed by CaridianBCT, with the Haemonetics Multicomponents System (MCS)+ apheresis system based on intermittent flow centrifugation. The primary objective of the study was to compare the time required to exchange one total plasma volume with both separators. The secondary objectives were to determine the plasma exchange efficiency, the plasma extraction rate, the percentage of target exchange volume achieved, and the loss of cellular components. The study involved prospectively paired comparison of 16 TPE on each device performed in patients with chronic diseases treated with TPE. The time required to exchange 1 total plasma volume was 182 ± 36 minutes for MCS+ procedures and 100 ± 20 minutes for the Spectra Optia procedures (P higher plasma extraction rate was achieved (30.2 ± 4.3 vs 16.8 ± 3.4 mL/min, respectively, P exchange efficiency was slightly better with the Spectra Optia compared with the MCS+ procedures (83.4 ± 7.0 vs 80.0 ± 8.5%, P higher extraction rate and exchange efficiency than the MCS+ allowing to remove the same amount of plasma in less time, by processing less blood. It also removes significantly less platelets than the MCS+ separator. Copyright © 2010 Wiley-Liss, Inc.

  7. Membrane versus centrifuge-based therapeutic plasma exchange: a randomized prospective crossover study.

    Science.gov (United States)

    Hafer, Carsten; Golla, Paulina; Gericke, Marion; Eden, Gabriele; Beutel, Gernot; Schmidt, Julius J; Schmidt, Bernhard M W; De Reys, Stef; Kielstein, Jan T

    2016-01-01

    Therapeutic plasma exchange (TPE) is either performed using a highly permeable filter with standard multifunctional renal replacement equipment (mTPE) or a centrifugation device (cTPE). Although both techniques are well established in clinical practice, performance of these two modes of TPE was never compared in a prospective randomized fashion. Thus we aimed to compare two commercially available therapeutic apheresis systems: mTPE (Octonova with Plasmaflo filter) and cTPE (Spectra Optia apheresis system). Twenty-one patients (age 51.6 ± 13.5 years; 10 F/11 M; BMI 25.1 ± 5.0 kg/m(2)) were enrolled in this randomized, prospective, paired, crossover study performed in the Hannover Medical School, Germany. First treatment (either mTPE or cTPE) was chosen by an online randomization list. The primary endpoints were plasma removal efficiency with 1.2× of the total plasma volume exchanged. Secondary endpoints were total amount of plasma substances removed, such as IgG and fibrinogen. Further, the treatment effect on platelet count and complications were evaluated. Despite a comparable volume of the processed plasma, mTPE treatment time was 10.5 % longer than cTPE treatment time (p centrifugal procedures were conducted using flow rates that could easily be obtained using peripheral access, plasma removal efficiency was significantly higher and treatment time was significantly lower in cTPE as compared to mTPE. Despite this lower treatment time, the decline in markers of procedure efficacy was comparable. Especially in centers performing many procedures per year, cTPE in contrast to mTPE can reduce treatment time without compromising treatment efficacy.

  8. The results of therapeutic plasma exchange in patients with severe hyperthyroidism: a retrospective multicenter study.

    Science.gov (United States)

    Keklik, Muzaffer; Kaynar, Leylagul; Yilmaz, Mehmet; Sivgin, Serdar; Solmaz, Musa; Pala, Cigdem; Aribas, Sulbiye; Akyol, Gulsah; Unluhizarci, Kursat; Cetin, Mustafa; Eser, Bulent; Unal, Ali

    2013-06-01

    Hyperthyroidism characterized by elevated serum levels of circulating thyroid hormones. The aim of hyperthyroidism treatment is to achieve a euthyroid state as soon as possible and to maintain euthyroid status. However, drug withdrawal and utilization of alternative therapies are needed in cases in which leucopenia or impairment in liver functions is observed during medical therapy. In the present study, we aimed to present our cases which underwent therapeutic plasma exchange (TPE) due to severe hyperthyroidism. The results of 22 patients who underwent therapeutic plasma exchange due to hyperthyroidism in Apheresis Units of Erciyes University and Gaziantep University, between 2006 and 2012, were retrospectively reviewed. These cases had severe thyrotoxic values despite anti-thyroid drug use. After TPE, we observed a significant decrease in free thyroxin (FT4) (phyperthyroidism by TPE in 20 cases (91%). Both FT3 and FT4 levels remained above the normal limits in two of 22 patients. TPE should be considered as an effective and safe therapeutic option to achieve euthyroid state before surgery or radioactive iodine treatment. TPE is a useful option in cases with severe hyperthyroidism unresponsive to anti-thyroid agents and in those with clinical manifestations of cardiac failure and in patients with severe adverse events during anti-thyroid therapy. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Treatment of carprofen overdose with therapeutic plasma exchange in a dog.

    Science.gov (United States)

    Kjaergaard, Astrid B; Davis, Jennifer L; Acierno, Mark J

    2018-06-13

    To report the use of therapeutic plasma exchange (TPE) in a dog with carprofen toxicosis. A 6-year-old female neutered Bichon Frise weighing 6.9 kg was examined after it had ingested 72 mg/kg carprofen. Mild dehydration without azotemia and with a urine specific gravity of 1.050 was noted at presentation. Treatment consisted of induction of emesis, symptomatic medical therapy, and TPE. The TPE achieved 1.5 plasma volume exchanges over 3 hours. Blood samples and effluent samples were collected every 30 minutes during TPE and additional blood samples were collected 11 and 35 hours after treatment. Carprofen concentrations in these samples were determined by high-pressure liquid chromatography. A 51% reduction in serum carprofen concentration was achieved following TPE. This report describes the successful reduction of plasma carprofen concentration in a dog using TPE. Although recent studies suggest that this particular dog may not have received a toxic dose, a 51% reduction of plasma carprofen concentration was achieved over 180 minutes, and TPE may be beneficial for treatment of dogs that have ingested higher doses. © Veterinary Emergency and Critical Care Society 2018.

  10. Therapeutic plasma exchange: a paired comparison of Fresenius AS104 vs. COBE Spectra.

    Science.gov (United States)

    Burgstaler, E A; Pineda, A A

    2001-01-01

    For therapeutic plasma exchange (TPE), continuous flow separators are known to be efficient as exemplified by Fresenius AS104 and COBE Spectra. The AS104 uses an interface monitoring system in the centrifuge during TPE, whereas Spectra uses computer algorithms to establish the plasma-cell interface. To determine the plasma collection efficiency (PLCE), anticoagulant (AC) volumes used, and platelets (PLT) lost of the AS104 and the Spectra, we performed a prospective paired comparison of 20 TPE (each machine). The study included 17 patients, 1.3 plasma volume exchanges (without AC), equal inlet rates, and AC ratio of 13:1. Processing times did not include reinfuse mode. Platelet loss was determined by sampling the collection bags. Inlet rates were between 60-110 ml/min. Diagnosis included peripheral neuropathies, TTP and cryoglobulinemia. The AS104 had significantly (P<0.0001) lower average whole blood processed (F:6,601 vs. S:8,584 ml), AC volume (F:532 vs. S:719 ml), and processing time (F:80 vs. S:102 minutes) than Spectra. The AS104 had significantly (P<0.0001) higher average plasma flow rates (F:53 vs. S:44 ml/minute), plasma collection efficiency (F:90 vs. S:69%), and platelet loss (F:2.0 vs. S:0.14 x 10(11) plt) than Spectra. Platelet loss correlated with inlet flow rate with the AS104 but not with the Spectra. The AS104 has a significantly higher collection efficiency than Spectra allowing it to remove the same amount of plasma in significantly less time, by processing significantly less blood, using significantly less AC, but removing significantly more platelets than Spectra. Copyright 2001 Wiley-Liss, Inc.

  11. Automated (Centrifugal) therapeutic plasma exchange option for guillain-barre syndrome: A report from Calabar, Nigeria.

    Science.gov (United States)

    Iheanacho, O E; Chimeziem, C; Sachais, B S; Shi, P A

    2017-10-01

    Therapeutic plasma exchange (TPE) is performed frequently and effectively in developed countries, whereas the reverse is the case in developing countries. Guillain-Barre syndrome (GBS), synonymous with acute inflammatory demyelinating polyneuropathy, is an important indication for TPE, but this is rarely administered in the treatment of such patients in Nigeria due to lack of such automated facility, limited expertise, and high cost. This report therefore presents an uncommon case of GBS in which automated TPE was utilized in the management, with the aims of highlighting the current status and challenges of therapeutic apheresis services in Nigeria. A 42-year-old male presented with rapidly progressive (in an ascending fashion) paralysis of all four limbs within 24 h without any preceding history of fever or other symptoms. Clinical examination revealed a young man, afebrile, not pale, and also not dehydrated. Central nervous system examination showed a conscious man, alert, and oriented in time, person, and place. There were no signs of meningeal irritation and the cranial nerves were grossly intact. There was no power in the limbs: global hypotonia and areflexia were noted on examination. However, he had intact sensory perceptions to touch and pain. Following a diagnosis of GBS, he was treated with four sessions of plasmapheresis and TPE. The TPE session was done using a discontinuous flow apheresis machine which exchanged one plasma volume (3 L of plasma) and 5% albumin used for replacement. The patient made gradual but steady recovery as return of power to the upper limbs and trunk started by the 2nd week of treatment. TPE is an important treatment modality in the management of GBS as well as several other conditions, and it is becoming increasingly available in Nigeria. However, it is still grossly underutilized, thus the need for more therapeutic apheresis facilities and trained personnel, in addition to concerted efforts to subsidize the cost of accessing

  12. Treatment of ibuprofen intoxication in a dog via therapeutic plasma exchange.

    Science.gov (United States)

    Walton, Stuart; Ryan, Kirk A; Davis, Jennifer L; Acierno, Mark

    2017-07-01

    To describe the treatment of ibuprofen intoxication with therapeutic plasma exchange in a dog (TPE). A 13-year-old male neutered mixed breed dog presented after ingesting approximately 200 mg/kg of ibuprofen. Treatment consisted of supportive medical therapy with IV fluids, gastrointestinal protectants, antiemetics and prostaglandin analogs, and TPE. A cycle of TPE was performed over 180 minutes, achieving 1.5 plasma volume exchanges. During therapy, heparinized blood and effluent samples were collected. Ibuprofen concentrations were determined in the samples by high-pressure liquid chromatography. Post TPE, the dog was continued on supportive medical therapy and was discharged 96 hours after the overdose. This report describes the use of TPE as an adjunct for ibuprofen intoxication. An 85% reduction in plasma ibuprofen concentration occurred and recovery from a potentially lethal ingestion of ibuprofen was achieved with TPE and supportive care. TPE should be considered when presented with acute ibuprofen intoxication due to the rapid and efficacious nature of therapy. © Veterinary Emergency and Critical Care Society 2017.

  13. Therapeutic plasma exchange performed in tandem with hemodialysis without supplemental calcium in the apheresis circuit.

    Science.gov (United States)

    Zhao, Yong; Ibrahim, Hiba; Bailey, Jeffrey A; Linden, Jeanne; Hickson, Elda; Haynes, Stefanie; Greene, Mindy; Vauthrin, Michelle; Weinstein, Robert

    2017-06-01

    Therapeutic plasma exchange (TPE) and hemopoietic progenitor cell (HPC) collection are apheresis procedures that can safely be performed in tandem with hemodialysis. Despite the return of citrate-anticoagulated blood to the patient during HPC collection, it is not necessary to administer supplemental calcium during these procedures because the ionized calcium concentration is restored as the returning blood passes through the dialyzer. It is not known whether this applies to TPE, in which a mixture of blood and pharmaceutical albumin, an avid binder of plasma ionized calcium, is returned to the patient through the dialyzer. We report on three dialysis-dependent patients who required TPE and underwent tandem treatments without supplemental calcium in the apheresis circuit. Overall, ionized calcium fell 4-12% (P = 0.0.024) and patients reported no symptoms of hypocalcemic toxicity. Tandem hemodialysis/TPE can be performed without supplemental calcium in the apheresis circuit. J. Clin. Apheresis 32:154-157, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  14. Effects of therapeutic plasma exchange on early allograft dysfunction after liver transplantation.

    Science.gov (United States)

    Choe, Wonho; Kwon, Seog-Woon; Kim, Sung-Soo; Hwang, Shin; Song, Gi-Won; Lee, Sung-Gyu

    2017-06-01

    Early allograft dysfunction (EAD) is a serious complication of liver transplantation (LT) and is associated with graft failure, which can result in patient mortality. Due to the shortage of organs for retransplantation, only a small proportion of EAD patients undergo retransplantation. Thus, liver support is needed for most patients with EAD. We evaluated the effects of therapeutic plasma exchange (TPE) in EAD patients. EAD was defined as a sustained hyperbilirubinemia (≥10 mg/dL) within 30 days of LT without concurrent biliary complications. In a 13-year period, 107 EAD patients underwent TPE while 36 EAD patients did not. We investigated the laboratory and clinical outcomes of TPE and non-TPE groups. The TPE group showed 1-month and 1-year survival rates of 82.2% and 53.8%, respectively, whereas the non-TPE group showed 58.3% and 22.2%, respectively. In TPE group, statistically significant decreases (P higher INR on the day of EAD onset increased the risk. TPE effectively removed plasma bilirubin and improved coagulation function in EAD patients, with higher survival in the TPE group than in the non-TPE group. TPE may be an effective liver support for EAD patients. J. Clin. Apheresis 32:147-153, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  15. Perfect storm: Therapeutic plasma exchange for a patient with thyroid storm.

    Science.gov (United States)

    McGonigle, Andrea M; Tobian, Aaron A R; Zink, Jennifer L; King, Karen E

    2018-02-01

    Thyroid storm is a potentially lethal complication of hyperthyroidism with increased thyroid hormones and exaggerated symptoms of thyrotoxicosis. First-line therapy includes methimazole (MMI) or propylthiouracil (PTU) to block production of thyroid hormones as a bridge toward definitive surgical treatment. Untreated thyroid storm has a mortality rate of up to 30%; this is particularly alarming when patients cannot tolerate or fail pharmacotherapy, especially if they cannot undergo thyroidectomy. Therapeutic plasma exchange (TPE) is an ASFA category III indication for thyroid storm, meaning the optimum role of this therapy is not established, and there are a limited number of cases in the literature. Yet TPE can remove T3 and T4 bound to albumin, autoantibodies, catecholamines and cytokines and is likely beneficial for these patients. We report a patient with thyroid storm who could not tolerate PTU, subsequently failed therapy with MMI, and was not appropriate for thyroidectomy. TPE was therefore performed daily for 4 days (1.0 plasma volume with 5% albumin replacement and 2 U of plasma). Over the treatment course, the patient's thyroid hormones normalized and symptoms of thyroid storm largely resolved; his T3 decreased from 2.27 to 0.81 ng/mL (normal 0.8-2.0), T4 decreased from 4.8 to 1.7 ng/mL (0.8-1.8), heart rate normalized, altered mental status improved, and he converted to normal sinus rhythm. He was ultimately discharged in euthyroid state. He experienced no side effects from his TPE procedures. TPE is a safe and effective treatment for thyroid storm when conventional treatments are not successful or appropriate. © 2017 Wiley Periodicals, Inc.

  16. Therapeutic plasma exchange in patients with pauciimmune vasculitis: Hospital Universitario San Ignacio experience; Bogotá, Colombia

    Directory of Open Access Journals (Sweden)

    Juan P. Córdoba

    2014-05-01

    Full Text Available Introduction: The vasculitis ANCAS positive, are a group of diseases with different clinical manifestations. Therapeutic plasma exchange has become an excellent tool for the treatment of these patients in specific conditions. Objective: Describe the demographic and clinical characteristics of patients and the final outcomes in patients with positive ANCAS vasculitis that required therapeutic plasma exchange (TPE. Materials and methods: All patients under 18 years old with positive ANCAS vascultiis that required TPE where included during the period of May 2010 and December 2013. Results: 13 patients where treated, with a total of 73 TPE sessions. The average age was 52,3 years (Range 17 to 70. The principal diagnosis for interventions was rapidly progressive glomerulonephritis (RPGN plus alveolar hemorrhage (63%. The average number of sessions per patient was 5,6 (range 1 a 10 with an average of plasma volume exchange per session of 1,26 (range 0.72 a 1,56. Of the 13 patients, 11 (84,6% required renal replacement therapy (RRT during hospitalization. At discharge, 36.3% recover the renal function, 27% continue on RRT and 36,3% died. There was at least one complication in 6,8% of all sessions. Conclusions: TPE is an excellent tool to treat patients with positive ANCAS vasculitis that present with RPGN, high levels of serum creatinine or dialysis need, or alveolar hemorrhage. This is a safe procedure with comparable results according to International literature.Key words: Apheresis, plasmapheresis, therapeutic plasma exchange, vasculitis, ANCA.

  17. Therapeutic plasma exchange in poisoning: 8 years' experience of a university hospital.

    Science.gov (United States)

    Dişel, Nezihat Rana; Akpınar, Ayça Açıkalın; Sebe, Ahmet; Karakoç, Emre; Sürer, Selen; Turhan, Ferda Tekin; Matyar, Selçuk

    2015-10-01

    This study examined the extracorporeal methods for the elimination of toxic substances in poisoned patients that are used by clinicians taking care of such patients. Here we present our experience in the use of therapeutic plasma exchange (TPE). To the best of our knowledge, this is the largest number of poisoning cases ever reported in a study. This is a retrospective study conducted at the Çukurova University Faculty of Medicine, Department of Emergency Medicine, with the permission of the ethical committee of the medical faculty. The study includes patients who had undergone TPE because of poisoning between January 2007 and May 2015. We summarize the clinical data and outcomes of the patients with available files. A total of 36 cases among the 42 patients who underwent TPE in this 8-year period were included in the study. More than 20 identified toxic substances, most of which were pesticides, were found to be the causes of poisoning. Twenty-three healthy discharges and 12 deaths are discussed in the study. We believe that our study reports the largest ever number of poisoning cases treated with TPE in the literature. When applicable, TPE may be a promising extracorporeal elimination and treatment technique in poisoned patients when performed in selected cases. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Therapeutic plasma exchange: an effective treatment in ethylene dibromide poisoning cases.

    Science.gov (United States)

    Pahwa, Naresh; Bharani, Rajesh; Jain, Manish; Argal, Suarabh; Soni, Harish; Kosta, Susmit; Kumar, Ravindra

    2013-10-01

    Ethylene dibromide (EDB) poisoning is very common in Central India and has fatal outcome. EDB is highly protein bound and, therefore, it is suggested that therapeutic plasma exchange (TPE) may be useful in removing drug from body shortly after ingestion before EDB metabolizes and causes severe end organ damage. The aim of our study is to find the effect of time of start of TPE on survival outcome of EDB poisoning cases. Fifty-eight cases of EDB poisoning were reviewed from 2007 to 2012 in Department of critical care medicine in tertiary care hospitals at Indore. Five patients were discharged against medical advice and lost to follow up. TPE was done in 47 patients as early as possible and irrespective of appearance of clinical symptoms. TPE was not performed in six cases as they were hypotensive at admission. The patients with EDB poisoning were 15-45 yrs old with 3:2 male to female ratio. Out of 47 who received TPE, 39 patients survived. TPE had started within 24 h of ingestions of EDB in 36 out of 39 survived patients. Survival outcome was nine times higher in patients who received TPE within 24 h than after 24 h of ingestion. Survival rate was increased to 100% in patients where TPE was done within 12 h of ingestion of EDB. Early TPE help to remove plasma protein bound toxin with significant mortality reduction. However, delay in start of TPE after ingestion of poison has significant poor survival outcome. Copyright © 2013 Wiley Periodicals, Inc.

  19. Two approaches to the clinical dilemma of treating TTP with therapeutic plasma exchange in patients with a history of anaphylactic reactions to plasma.

    Science.gov (United States)

    Sidhu, Davinder; Snyder, Edward L; Tormey, Christopher A

    2017-06-01

    Thrombotic thrombocytopenic purpura (TTP) is a rare but serious disease caused by autoantibody-mediated deficiency in von Willebrand factor (VWF) cleaving protease, ADAMTS-13. The primary acute treatment is therapeutic plasma exchange (TPE). However, some patients can develop allergic/anaphylactic reactions to the replacement (i.e., donor) plasma over time. Two potential treatment strategies for patients with TTP who demonstrate severe allergic reactions to plasma used for exchange were examined. Two patients with TTP exacerbations who developed severe allergic reactions to donor plasma were identified. One patient's TPE was re-initiated with Octaplas, a lot-batched solvent and detergent treated, type-specific, pooled donor plasma product. The other patient was exchanged with primarily albumin, followed by slow incremental exposures to donor plasma to mitigate exposures and allergic risks. Both patients were assessed for anaphylaxis. Both treatment strategies were successful in preventing any further clinically significant allergic/anaphylactic reactions and facilitated both patients' TTP remissions. Based on our experience with two similar patients with TTP exacerbations and history of anaphylactic reactions to plasma during TPE, we have identified two possible treatment protocols to achieve remission in this clinical dilemma. Substituting Octaplas for standard plasma or, alternatively, using albumin with slowly increasing amounts of standard plasma may help to mitigate the risk of further anaphylactic adverse events. J. Clin. Apheresis 32:158-162, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  20. Experience in therapeutic plasma exchange by membrane filtration at an academic center in Colombia: Registry of the first 500 sessions.

    Science.gov (United States)

    Córdoba, Juan Pablo; Larrarte, Carolina; Medina, María Camila

    2015-12-01

    Therapeutic plasma exchange (TPE) is an extracorporeal blood purification therapy that is part of the treatment of various diseases. Plasma and blood cells can be separated by centrifugation or using membrane separators. A descriptive analysis, in which the first 500 TPE sessions using membrane filtration without anticoagulation of the extracorporeal circuit are described. Five hundred (500) TPE sessions were performed on 68 patients over a period of 5 years. Therapeutic indications were 17 different diseases. 5% albumin was the most frequent replacement solution used in 62% of sessions. The mean number of plasma volume replacements was 1.33. Complications occurred in 7.6% of the sessions. Arterial hypotension was the most common event and clotting of the extracorporeal circuit was documented in just one TPE session. Electrolyte tests performed in patients during the procedure showed: 11% hypocalcemia, with a similar distribution of hypokalemia. Twenty-two percent (22%) and 37% of phosphorus and magnesium records, respectively, were higher than normal. No symptoms associated with electrolyte abnormalities were documented. TPE by membrane filtration is one of the techniques by which it is possible to perform such therapy. In this registry, a low rate of complications was documented. While the need for anticoagulation may be related not only to clotting of the circuit but also to the efficiency of the therapy, clinical response in this series of patients was as expected for each disease. Continuous monitoring and an individualized analysis of electrolytes should be performed in TPE patients. © 2015 Wiley Periodicals, Inc.

  1. Role of Therapeutic Plasma Exchange in Treatment of Tumefactive Multiple Sclerosis-Associated Low CD4 and CD8 Levels

    Directory of Open Access Journals (Sweden)

    Kristen Lew

    2016-08-01

    Full Text Available We report a 35-year-old healthy male who developed central nervous system inflammatory demyelinating disease consistent with tumefactive multiple sclerosis. About 2 weeks after onset of symptoms and prior to initiation of therapy, the patient had lymphopenia and low CD4 and CD8 levels. His lymphocyte count was 400 cells/µl (850–3,900 cells/µl, CD4 was 193 cells/µl (490–1,740 cells/µl and CD8 was 103 cells/µl (180–1,170 cells/µl. He was treated with intravenous methylprednisolone followed by therapeutic plasma exchange, the levels of CD4 and CD8 normalized, and ultimately, he recovered completely.

  2. Effects of therapeutic plasma exchange on serum immunoglobulin concentrations in a dog with refractory immune-mediated hemolytic anemia.

    Science.gov (United States)

    Scagnelli, Alyssa M; Walton, Stuart A; Liu, Chin-Chi; Acierno, Mark J

    2018-05-01

    CASE DESCRIPTION A 9-year-old 8.3-kg (18.3-lb) neutered male Miniature Schnauzer was referred for diagnosis and treatment of a sudden onset of lethargy, anorexia, vomiting, and pallor. CLINICAL FINDINGS On physical examination, the dog was lethargic with pale mucous membranes and a capillary refill time ≥ 2 seconds. Skin and sclera were mildly icteric. Signs of pain were elicited during abdominal palpation, and an enlarged spleen was noted. Results of agglutination testing and cytologic findings were consistent with immune-mediated hemolytic anemia (IMHA). No contributing factors for development of IMHA were identified. TREATMENT AND OUTCOME Initial treatment included management with immunosuppressant medications. Three packed RBC transfusions were administered, but clinical signs continued to progress. Therefore, therapeutic plasma exchange (TPE) was performed 5 and 9 days after admission. Following each TPE procedure, the dog had an appreciable clinical improvement and decrease in RBC autoagglutination, and the Hct stabilized. Serum IgG and IgM concentrations were measured during and after both TPE procedures. Despite anticoagulative treatment, the dog developed a thrombus in the splenic vein, necessitating a splenectomy. CLINICAL RELEVANCE The decrease and rebound in serum IgG and IgM concentrations following TPE provided evidence that TPE may have the same immunomodulatory effects in dogs as have been proposed to occur in people. Further, findings suggested that TPE may be a useful alternative in dogs with refractory IMHA when traditional treatments fail.

  3. Severe Hyperthyroidism Complicated by Agranulocytosis Treated with Therapeutic Plasma Exchange: Case Report and Review of the Literature.

    Science.gov (United States)

    Garla, Vishnu; Kovvuru, Karthik; Ahuja, Shradha; Palabindala, Venkatataman; Malhotra, Bharat; Abdul Salim, Sohail

    2018-01-01

    To present a case of Graves' disease complicated by methimazole induced agranulocytosis treated with therapeutic plasma exchange (TPE) and review of the literature. A 21-year-old patient with a history of Graves' disease presented to the endocrine clinic. His history was significant for heat intolerance, weight loss, and tremors. Upon examination he had tachycardia, smooth goiter, thyroid bruit, and hyperactive reflexes. He was started on methimazole and metoprolol and thyroidectomy was to be done once his thyroid function tests normalized. On follow-up, the patient symptoms persisted. Complete blood count done showed a white blood cell count of 2100 (4000-11,000 cells/cu mm) with a neutrophil count of 400 cells/cu mm, consistent with neutropenia. He was admitted to the hospital and underwent 3 cycles of TPE and was also given filgrastim. He improved clinically and his thyroxine (T4) levels also came down. Thyroidectomy was done. He was discharged on levothyroxine for postsurgical hypothyroidism. Plasmapheresis may be useful in the treatment of hyperthyroidism. It works by removing protein bound hormones and also possibly inflammatory cytokines. Further studies are needed to clarify the role of various modalities of TPE in the treatment of hyperthyroidism.

  4. Severe Hyperthyroidism Complicated by Agranulocytosis Treated with Therapeutic Plasma Exchange: Case Report and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Vishnu Garla

    2018-01-01

    Full Text Available Aim. To present a case of Graves’ disease complicated by methimazole induced agranulocytosis treated with therapeutic plasma exchange (TPE and review of the literature. Case Presentation. A 21-year-old patient with a history of Graves’ disease presented to the endocrine clinic. His history was significant for heat intolerance, weight loss, and tremors. Upon examination he had tachycardia, smooth goiter, thyroid bruit, and hyperactive reflexes. He was started on methimazole and metoprolol and thyroidectomy was to be done once his thyroid function tests normalized. On follow-up, the patient symptoms persisted. Complete blood count done showed a white blood cell count of 2100 (4000–11,000 cells/cu mm with a neutrophil count of 400 cells/cu mm, consistent with neutropenia. He was admitted to the hospital and underwent 3 cycles of TPE and was also given filgrastim. He improved clinically and his thyroxine (T4 levels also came down. Thyroidectomy was done. He was discharged on levothyroxine for postsurgical hypothyroidism. Conclusion. Plasmapheresis may be useful in the treatment of hyperthyroidism. It works by removing protein bound hormones and also possibly inflammatory cytokines. Further studies are needed to clarify the role of various modalities of TPE in the treatment of hyperthyroidism.

  5. Mechanisms of Plasma Therapeutics

    Science.gov (United States)

    Graves, David

    2015-09-01

    In this talk, I address research directed towards biomedical applications of atmospheric pressure plasma such as sterilization, surgery, wound healing and anti-cancer therapy. The field has seen remarkable growth in the last 3-5 years, but the mechanisms responsible for the biomedical effects have remained mysterious. It is known that plasmas readily create reactive oxygen species (ROS) and reactive nitrogen species (RNS). ROS and RNS (or RONS), in addition to a suite of other radical and non-radical reactive species, are essential actors in an important sub-field of aerobic biology termed ``redox'' (or oxidation-reduction) biology. It is postulated that cold atmospheric plasma (CAP) can trigger a therapeutic shielding response in tissue in part by creating a time- and space-localized, burst-like form of oxy-nitrosative stress on near-surface exposed cells through the flux of plasma-generated RONS. RONS-exposed surface layers of cells communicate to the deeper levels of tissue via a form of the ``bystander effect,'' similar to responses to other forms of cell stress. In this proposed model of CAP therapeutics, the plasma stimulates a cellular survival mechanism through which aerobic organisms shield themselves from infection and other challenges.

  6. Therapeutic plasma exchange versus double plasma molecular absorption system in hepatitis B virus-infected acute-on-chronic liver failure treated by entercavir: A prospective study.

    Science.gov (United States)

    Wan, Yue-Meng; Li, Yu-Hua; Xu, Zhi-Yuan; Yang, Jing; Yang, Li-Hong; Xu, Ying; Yang, Jin-Hui

    2017-12-01

    Therapeutic plasma exchange (TPE) and double plasma molecular absorption system (DPMAS) were two extracorporeal liver support systems. Few studies compared their efficacy profile. This study was to compare the efficacy of TPE and DPMAS on acute-on-chronic liver failure (ACLF) caused by hepatitis B virus (HBV-ACLF). 60 HBV-ACLF patients were enrolled and prospectively studied. All patients received entecavir therapy, and were assigned to TPE group (n = 33) and DPMAS group (n = 27). Primary end-points were the effects of TPE and DPMAS on liver function and serum inflammatory markers. Serum procalcitonin, interleukin (IL)-6, and high sensitive C-reactive protein (hsCRP) were significantly elevated in patients with HBV-ACLF. TPE achieved significantly higher removal rates of total bilirubin (TBIL, P = .002), direct bilirubin (DBIL, P = .006), and hsCRP (P = .010) than DPMAS, but DPMAS displayed lower loss rate of albumin (P = .000). TPE and DPMAS resulted in similarly increased serum IL-6 levels and comparable 12-week survivals (P > .05). Multivariate analysis showed that hospital stay (Relative Risk [RR]: 1.062, 95% Confidence Interval [CI]: 1.011-1.115, P = .016), prothrombin time (RR: 1.346, 95% CI: 1.077-1.726, P = .010), and international normalized ratio (RR: 0.013, 95% CI: 0.006-0.788, P = .041) were independent predictors for 12-week survival. Both TPE and DPMAS treatments were well-tolerated. Compared to DPMAS, TPE was more efficient in eliminating TBIL, DBIL, and hsCRP, but it was associated with higher loss rate of albumin. TPE and DPMAS were similar in improving 12-week survivals in HBV-ACLF. © 2017 Wiley Periodicals, Inc.

  7. Changes in hemostasis caused by different replacement fluids and outcome in therapeutic plasma exchange in pediatric patients in a retrospective single center study.

    Science.gov (United States)

    Witt, Volker; Pichler, Herbert; Beiglboeck, Elisabeth; Kursten, Friedrich; Weidner, Lisa

    2017-02-01

    Therapeutic plasma exchange (TPE) is a generally accepted and frequently performed procedure for numerous therapeutic indications in adults. Slowly, TPE is also becoming more and more popular in the treatment of pediatric patients. Although, we know that TPE is safe in pediatric patients, the outcome of children treated with TPE is rarely reported. Furthermore, there are only general recommendations regarding the plasma replacement fluid for children and these are adopted from adults. Data concerning outcome and the influence of different types of replacement fluids on hemostasis in children are scarce. We retrospectively evaluated 324 TPE treatments performed in 35 patients between 2008 and 2013 in our level 4 institution for pediatric hematology and oncology. The plasmapheresis procedures were categorized into three groups based on the replacement fluid used. The first group received solvent/detergent-treated (S/D) plasma (70.0% of patients), the second group was administered 5% human albumin (7.7% of patients) and the third group was treated with a combination of human albumin 5% and S/D plasma (22.3% of patients). To assess hemostasis, data on INR, aPTT, fibrinogen and ATIII were collected before and after plasmapheresis from the patients' charts. A modified Multi Organ Dysfunction Syndrome (MODS) Index was used to classify organ failure. Patient outcome, survival rate and adverse events were evaluated. We found a significant increase in the INR by 35.83% and of the aPTT by 18.53% within the human albumin group. The INR and aPTT of patients allocated to the S/D plasma group decreased by 1.58% and 15.77% on average, respectively. The combination group revealed a mild increase of the INR (9.47%), accompanied by a reduction of aPTT (5.97%). Furthermore we found that the survival rate was significantly associated with a MODS Index of <2 (p<0.001). Overall, the number of adverse events was low (1.2%) and none of these were considered life-threatening. Hemostasis

  8. Response to Therapeutic Plasma Exchange as a Rescue Treatment in Clinically Isolated Syndromes and Acute Worsening of Multiple Sclerosis: A Retrospective Analysis of 90 Patients.

    Directory of Open Access Journals (Sweden)

    Johannes Ehler

    Full Text Available Experience with therapeutic plasma exchange (TPE for acute relapses in clinically isolated syndrome (CIS or multiple sclerosis (MS patients has been derived from small and inhomogeneous patient populations so far. In the present study, we retrospectively evaluated features associated with TPE response in a larger cohort of CIS and MS patients with acute worsening of disease.Ninety CIS and MS patients with acute relapses or acute worsening of symptoms were firstly treated with TPE. The population consisted of 62 women and 28 men with a median age of 38 years (range 18-69 years.Primary endpoint was the clinical response to TPE, focused on the functional improvement of the target neurologic deficit. Secondary endpoint was an improvement in expanded disability status scale (EDSS scoring.A clinical response to TPE was observed in 65 out of 90 patients (72.2%, with marked improvement in 18 (20.0% and moderate improvement in 47 out of 90 patients (52.2%. The median EDSS was reduced from 3.75 before to 3.0 after TPE (p = 0.001. Response to TPE was significantly more frequent in patients with relapsing courses of disease (CIS, RR-MS, p = 0.001, no disease modifying drugs (p = 0.017, gadolinium-positive (Gd+ MRI lesions (p = 0.001 and EDSS ≤ 5.0 before TPE (p = 0.014. In the multiple logistic regression analysis only the detection of Gd+ MRI lesions was significantly altered (p = 0.004.Clinical response to TPE was achieved in the majority of our patients. We identified clinical and diagnostic features in CIS and MS relapses that might be helpful to identify patients responding to TPE. Gd+ MRI lesions before treatment were the best predictor of the response to TPE in our cohort.

  9. Evaluation of the therapeutic efficacy of lamivudine combined with plasma exchange for treating acute-on-chronic hepatitis B liver failure

    Directory of Open Access Journals (Sweden)

    HU Qijiang

    2013-02-01

    Full Text Available ObjectiveTo observe the clinical effects of lamivudine antiviral therapy combined with plasma exchange in patients with acute-on-chronic hepatitis B liver failure. MethodsForty-seven patients (treatment group were administered lamivudine and underwent plasma exchange. An additional forty-five patients (control group were administered lamivudine but no plasma exchange. Otherwise, all patients received the same basic medical treatment. The two groups were further divided into three sub-groups according to the model for end-stage liver disease (MELD score: <30, 30-39, and ≥40. The significance of differences in survival rates between the groups and sub-groups was determined by the χ2 test. ResultsThe overall survival rate was significantly better in the treatment group (63.82% vs. control group: 44.44%; χ2=4.31, P<0.05. Within the treatment group, the survival rates were highest in the 30-39 MELD score sub-group (71.42%, which was significantly different from survival rate in the same sub-group of the controls (vs. 38.10%; χ2=4.71, P<005. The other two MELD score sub-groups showed no significant differences between the treatment and control groups (all P>0.05. ConclusionCombined therapy consisting of lamivudine treatment and plasma exchange can improve the survival rate of patients with acute-on-chronic hepatitis B liver failure who have MELD scores between 30 and 39.

  10. GEC Plasma Data Exchange Project

    Science.gov (United States)

    Pitchford, L. C.

    2013-08-01

    In 2010 the Gaseous Electronics Conference (GEC), a major international conference for the low temperature plasma science (LTPS) community, initiated the Plasma Data Exchange Project (PDEP). The PDEP is an informal, community-based project that aims to address, at least in part, the well-recognized needs for the community to organize the means of collecting, evaluating and sharing data both for modelling and for interpretation of experiments. The emphasis to date in the PDEP has been on data related to the electron and ion components of these plasmas rather than on the plasma chemistry. At the heart of the PDEP is the open-access website, LXCat [1], developed by researchers at LAPLACE (Laboratoire Plasma et Conversion d'Energie, Toulouse, France). LXCat is a platform for archiving and manipulating collections of data related to electron scattering and transport in cold, neutral gases, organized in databases set-up by individual members or institutions of the LTPS community. At present, 15 databases of electron scattering data, contributed by groups around the world, can be accessed on LXCat. These databases include complete sets of electron cross sections, over an energy range from thermal to nominally 1 keV, for almost 40 ground-state neutral species and partial sets of data for about 30 other neutral, excited and ionized species. 'Complete' implies that all the major electron momentum and energy loss processes are well described in the dataset. Such 'complete' datasets can be used as input to a Boltzmann calculation of the electron energy distribution function (generally non-Maxwellian), and electron transport and rate coefficients can be obtained in pure gases or mixtures by averaging over the distribution function. Online tools enable importing and exporting data, plotting and comparing different sets of data. An online version of the Boltzmann equation solver BOLSIG+ [2] is also available on the LXCat site. Other members of the community have contributed their

  11. Automated (Centrifugal) Therapeutic Plasma Exchange Option for ...

    African Journals Online (AJOL)

    Central nervous system examination showed a conscious man, alert, and oriented in time, person, and place. There were no signs of meningeal irritation and the cranial nerves were grossly intact. There was no power in the limbs: global hypotonia and areflexia were noted on examination. However, he had intact sensory ...

  12. Plasma exchange in Goodpasture syndrome associated with ...

    African Journals Online (AJOL)

    Background: Good pasture syndrome (GPS) has been paid much attention recently for the dangerous illnessand high mortality. Objective: To investigate the efficiency of plasma exchange (PE) to treat Goodpasture syndrome (GPS) in children associated with Turner's syndrome. Method: We report a case of a 15 year old ...

  13. Plasma exchange in progressive systemic sclerosis

    Directory of Open Access Journals (Sweden)

    Mohammad Bagher Owlia

    2015-10-01

    Full Text Available Systemic sclerosis (SSc is an autoimmune systemic disease of unknown etiology. Present treatment modalities have limited impact on clinical/ laboratory outcomes. For the first time in our center, we used plasma exchange (PEx in a rather young woman with recent onset but progressive SSc. She is a 39-year-old woman with a recent history of skin stiffness, Raynaud’s phenomenon, nail fold capillary changes and newly diagnosis of SSc presented to us due to worsening her clinical symptoms even after initiation of routine remedies such as low dose oral prednisolone, Ca-channel blockers, azathioprine and pentoxyfylline. After obtaining written consent, interdisciplinary discussion with experts in this field and agreement we started a series of plasma exchange with FFP replacement for her. A dramatic clinical response was observed in respect to Raynaud’s phenomenon, skin stiffness, tendon rub after three sessions of PEx. Her modified Rodnan skin score (MRSS dropped from 36 (before commencement of therapy to 28 in day 4 and 18 in day 20 after 15 sessions of PEx. In conclusion PEx could significantly modify the course of SSc as observed in our case study. Elimination of culprit immune mediators/cytokines/autoantibodies could be the possible mechanism of action of PEx. 

  14. Moderator's view: High-volume plasma exchange: pro, con and consensus.

    Science.gov (United States)

    Kaplan, Andre A

    2017-09-01

    I have been asked to comment on the pro and con opinions regarding high-volume plasma exchange. The authors of both positions have provided cogent arguments and a reasonable approach to choosing the exchange volume for any given therapeutic plasma exchange. The major issue of relevance in this discussion is the nature of the toxins targeted for removal. These parameters include molecular weight, the apparent volume of distribution, the degree of protein binding, the biologic and chemical half-life, and the severity and rapidity of its toxicity. © The Author 2017. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  15. Post-transfusion purpura treated with plasma exchange by haemonetics cell separator. A case report

    DEFF Research Database (Denmark)

    Laursen, B; Morling, N; Rosenkvist, J

    1978-01-01

    A case of post-transfusion purpura in a 61-year-old, multiparous female with a platelet alloantibody (anti-Zwa) in her serum is reported. The patient was successfully treated with plasma exchange by means of a Haemonetics 30 cell separator and corticosteroids. Compared with other therapeutic...

  16. Fibrinogen Reduction During Selective Plasma Exchange due to Membrane Fouling.

    Science.gov (United States)

    Ohkubo, Atsushi; Okado, Tomokazu; Miyamoto, Satoko; Hashimoto, Yurie; Komori, Shigeto; Yamamoto, Motoki; Maeda, Takuma; Itagaki, Ayako; Yamamoto, Hiroko; Seshima, Hiroshi; Kurashima, Naoki; Iimori, Soichiro; Naito, Shotaro; Sohara, Eisei; Uchida, Shinichi; Rai, Tatemitsu

    2017-06-01

    Fibrinogen is substantially reduced by most plasmapheresis modalities but retained in selective plasma exchange using Evacure EC-4A10 (EC-4A). Although EC-4A's fibrinogen sieving coefficient is 0, a session of selective plasma exchange reduced fibrinogen by approximately 19%. Here, we investigated sieving coefficient in five patients. When the mean processed plasma volume was 1.15 × plasma volume, the mean reduction of fibrinogen during selective plasma exchange was approximately 15%. Fibrinogen sieving coefficient was 0 when the processed plasma volume was 1.0 L, increasing to 0.07 when the processed plasma volume was 3.0 L, with a mean of 0.03 during selective plasma exchange. When fibrinogen sieving coefficient was 0, selective plasma exchange reduced fibrinogen by approximately 10%. Scanning electron microscopy images revealed internal fouling of EC-4A's hollow fiber membrane by substances such as fibrinogen fibrils. Thus, fibrinogen reduction by selective plasma exchange may be predominantly caused by membrane fouling rather than filtration. © 2017 International Society for Apheresis, Japanese Society for Apheresis, and Japanese Society for Dialysis Therapy.

  17. Fine structure of charge exchange lines observed in laboratory plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Ida, K.; Nishimura, S. [National Inst. for Fusion Science, Nagoya (Japan); Kondo, K.

    1997-01-01

    The influence of the fine structure of charge exchange lines appears only at the plasma edge or in the recombining phase where the ion temperature is low enough. The observed spectra in Li III and C VI are consistent with the sum of fine-structure components populated by statistical weights (assuming complete l-mixing) not by direct charge exchange cross sections. Some discrepancy was observed in the intensity ratio of fine-structure components between the observation and calculation for C VI in the recombining phase. The fine-structure of charge exchange lines gives an apparent Doppler shift in plasma rotation velocity measurement using charge exchange spectroscopy. (author)

  18. Plasma exchange for Guillain-Barré syndrome.

    Science.gov (United States)

    Raphaël, J C; Chevret, S; Hughes, R A; Annane, D

    2002-01-01

    Guillain-Barré syndrome is an acute symmetric, usually ascending and usually paralysing illness, due to inflammation of peripheral nerves. It is thought to be caused by autoimmune factors, such as antibodies. Plasma exchange removes antibodies and other potentially injurious factors from the blood stream. It involves connecting the patient's blood circulation to a machine which exchanges the plasma for a substitute solution, usually albumin. Several studies have evaluated plasma exchange for Guillain-Barré syndrome. To systematically review the evidence concerning the efficacy of plasma exchange for treating Guillain-Barré syndrome. Search of the Cochrane Neuromuscular Disease Trial Register for randomised trials concerning plasma exchange in Guillain-Barré syndrome, search of the bibliographies of identified papers and enquiry from the authors of the papers. Randomised and quasi-randomised trials of plasma exchange versus sham exchange or supportive treatment. Potentially relevant papers were scrutinised by two reviewers and the selection of eligible studies was agreed by them and a third reviewer. Data were extracted by one reviewer and checked by a second reviewer. Some missing data were obtained from the authors of studies. Six eligible trials concerning 649 patients were identified, all comparing plasma exchange versus supportive treatment alone. Primary outcome measures ~bullet~Time to recover walking with aid In the only two trials for which this measure was reported, the median time to recover this ability was faster in the plasma exchange than the control group. ~bullet~Time to onset of motor recovery in mildly affected patients In the one trial for which this measure was available, the time was significantly shortened in the plasma exchange group. Secondary outcome measures ~bullet~Improvement in disability grade at four weeks In five trials, there were significantly more patients who had improved by one disability grade or more in the plasma exchange

  19. Charge exchange in a divertor plasma with excited particles

    International Nuclear Information System (INIS)

    Krasheninnikov, S.I.; Lisitsa, V.S.; Pigarov, A.Y.

    1988-01-01

    A model is constructed for the dynamics of neutral atoms and multicharged ions in a tokamak plasma. The influence of cascade excitation on charge exchange and ionization is taken into account. The effective rates of the resonant charge exchange of a proton with a hydrogen atom, the nonresonant charge exchange of a helium atom with a proton, and that of an α particle with atomic hydrogen are calculated as functions of the parameters of the divertor plasma in a tokamak. The charge exchange H + +He→H+He + can represent a significant fraction (∼30%) of the total helium ionization rate. Incorporating the charge exchange of He 2+ with atomic hydrogen under the conditions prevailing in the divertor plasma of the INTOR reactor can lead to substantial He 2+ →He + conversion and thereby reduce the sputtering of the divertor plates by helium ions

  20. Charge exchange cooling in the tandem mirror plasma confinement apparatus

    Science.gov (United States)

    Logan, B. Grant

    1978-01-01

    Method and apparatus for cooling a plasma of warm charged species confined in the center mirror cell of the tandem mirror apparatus by injecting cold neutral species of the plasma into at least one mirroring region of the center mirror cell, the cooling due to the loss of warm charged species through charge exchange with the cold neutral species with resulting diffusion of the warm neutral species out of the plasma.

  1. Charge exchange cooling in the tandem mirror plasma confinement apparatus

    International Nuclear Information System (INIS)

    Logan, B.G.

    1978-01-01

    A method and apparatus are described for cooling a plasma confined in the center mirror cell of the tandem mirror apparatus by injecting cold neutral species of the plasma into at least one mirroring region of the center mirror cell. The cooling is due to the loss of warm charged species through charge exchange with the cold neutral species with resulting diffusion of the warm neutral species out of the plasma

  2. Plasma exchange for renal vasculitis and idiopathic rapidly progressive glomerulonephritis: a meta-analysis

    DEFF Research Database (Denmark)

    Walsh, Michael; Catapano, Fausta; Szpirt, Wladimir

    2011-01-01

    Plasma exchange may be effective adjunctive treatment for renal vasculitis. We performed a systematic review and meta-analysis of randomized controlled trials of plasma exchange for renal vasculitis.......Plasma exchange may be effective adjunctive treatment for renal vasculitis. We performed a systematic review and meta-analysis of randomized controlled trials of plasma exchange for renal vasculitis....

  3. Plasma Exchange in Severe Attacks of Neuromyelitis Optica

    Directory of Open Access Journals (Sweden)

    Mickael Bonnan

    2012-01-01

    Full Text Available Background. Neuromyelitis optica (NMO attacks are poorly controlled by steroids and evolve in stepwise neurological impairments. Assuming the strong humoral response underlying NMO attacks, plasma exchange (PLEX is an appropriate technique in severe NMO attacks. Objective. Presenting an up-to-date review of the literature of PLEX in NMO. Methods. We summarize the rationale of PLEX in relation with the physiology of NMO, the main technical aspects, and the available studies. Results. PLEX in severe attacks from myelitis or optic neuritis are associated with a better outcome, depending on PLEX delay (“time is cord and eyes”. NMO-IgG status has no influence. Finally, we build up an original concept linking the inner dynamic of the lesion, the timing of PLEX onset and the expected clinical results. Conclusion. PLEX is a safe and efficient add-on therapy in NMO, in synergy with steroids. Large therapeutic trials are required to definitely assess the procedure and define the time opportunity window.

  4. Plasma Exchange in the Management of Catastrophic Antiphospholipid Syndrome

    Directory of Open Access Journals (Sweden)

    Dimitri Titeca-Beauport

    2016-01-01

    Full Text Available Objective. Report of a case of catastrophic antiphospholipid syndrome (CAPS with multiple organ involvement leading to a life-threatening condition despite early combination corticosteroid and heparin therapy. Initiation of plasma exchange led to rapid improvement of the patient’s general condition. Design. Case report. Setting. University teaching hospital medical intensive care unit. Patient. Single case: 52-year-old man hospitalized for catastrophic antiphospholipid syndrome (CAPS with cardiac, renal, and cutaneous involvement. Despite early methylprednisolone and heparin therapy, the patient’s condition progressively deteriorated, resulting in acute renal failure, right adrenal hemorrhage, and pulmonary involvement, leading to acute respiratory distress on day 6, requiring high-flow nasal cannula oxygen therapy with FiO2 of 1.0. Interventions. Plasma exchange was started on day 6. Endpoints and Main Results. A marked improvement of the patient’s general condition was observed after initiation of plasma exchange, with successful weaning of oxygen therapy and normalization of platelet count, troponin, and serum creatinine within four days. Conclusions. This case illustrates the efficacy of plasma exchange in CAPS and the difficulty for physicians to determine the optimal timing of plasma exchange.

  5. Haemorrheological response to plasma exchange in Raynaud's syndrome.

    Science.gov (United States)

    Dodds, A J; O'Reilly, M J; Yates, C J; Cotton, L T; Flute, P T; Dormandy, J A

    1979-11-10

    Eight patients with Raynaud's syndrome were treated by weekly plasma exchange for four weeks using a Haemonetics Model 30 Blood Processor. The mean whole-blood viscosity at a shear rate of 0.77/s was significantly lower after treatment, and the mean index of red-cell deformability was significantly improved. In four patients studied serially the mean percentage fall in whole-blood viscosity after a single plasma exchange was 49% at 0.77/s but only 14% at 91/s. All patients noticed symptomatic improvement including healing of ischaemic digital ulcers. In six patients the number of digital arterial segments containing detectable blood flow was measured by directional Doppler; in all six the number increased. It is concluded that plasma exchange is an effective means of haemorrheological treatment and may be beneficial in patients with digital ischaemia.

  6. Plasma stream transport method (2) Use of charge exchange plasma source

    International Nuclear Information System (INIS)

    Tsuchimoto, T.

    1978-01-01

    The plasma stream transport method using a single plasma source has limitations for practical film deposition. Using a charge exchange phenomenon, a new plasma source is devised and tested by the plasma stream transport machine. Metals, silicon dioxide, and nitride films are deposited by this system. The mechanism of deposition under relatively high vacuum surrounding a silicon wafer is discussed as is the effect of radical atoms

  7. Resonant charge exchange for H-H+ in Debye plasmas

    Science.gov (United States)

    Laricchiuta, Annarita; Colonna, Gianpiero; Capitelli, Mario; Kosarim, Alexander; Smirnov, Boris M.

    2017-11-01

    The dynamics of resonant charge exchange in proton-hydrogen collisions embedded in plasma is investigated in the framework of the asymptotic approach, modified to account for the effect of Debye-Hückel screening in particle interactions. The cross sections exhibit a marked dependence on the Debye length in regimes of severe plasma confinement. Processes involving excited states H( n)-H+ are also discussed.

  8. Plasma Exchange for Refractory MDA5 Myositis and ILD

    Science.gov (United States)

    2017-04-26

    plasma exchange, the patient had improvement of hypocarbic respiratory alkalosis and reversal of myositis with resolution of dysphagia/odynophagia and...symptoms with respiratory distress. A five day course of plasmapheresis was initiated on hospital day eight. Subsequently his respiratory acid-base

  9. Energy exchange in strongly coupled plasmas with electron drift

    International Nuclear Information System (INIS)

    Akbari-Moghanjoughi, M.; Ghorbanalilu, M.

    2015-01-01

    In this paper, the generalized viscoelastic collisional quantum hydrodynamic model is employed in order to investigate the linear dielectric response of a quantum plasma in the presence of strong electron-beam plasma interactions. The generalized Chandrasekhar's relativistic degeneracy pressure together with the electron-exchange and Coulomb interaction effects are taken into account in order to extend current research to a wide range of plasma number density relevant to big planetary cores and astrophysical compact objects. The previously calculated shear viscosity and the electron-ion collision frequencies are used for strongly coupled ion fluid. The effect of the electron-beam velocity on complex linear dielectric function is found to be profound. This effect is clearly interpreted in terms of the wave-particle interactions and their energy-exchange according to the sign of the imaginary dielectric function, which is closely related to the wave attenuation coefficient in plasmas. Such kinetic effect is also shown to be in close connection with the stopping power of a charged-particle beam in a quantum plasma. The effect of many independent plasma parameters, such as the ion charge-state, electron beam-velocity, and relativistic degeneracy, is shown to be significant on the growing/damping of plasma instability or energy loss/gain of the electron-beam

  10. Oscillatory wake potential with exchange-correlation in plasmas

    Science.gov (United States)

    Khan, Arroj A.; Zeba, I.; Jamil, M.; Asif, M.

    2017-12-01

    The oscillatory wake potential of a moving test charge is studied in quantum dusty plasmas. The plasma system consisting of electrons, ions and negatively charged dust species is embedded in an ambient magnetic field. The modified equation of dispersion is derived using a Quantum Hydrodynamic Model for magnetized plasmas. The quantum effects are inculcated through Fermi degenerate pressure, the tunneling effect and exchange-correlation effects. The study of oscillatory wake is important to know the existence of silence zones in space and astrophysical objects as well as for crystal formation. The graphical description of the potential depicts the significance of the exchange and correlation effects arising through spin and other variables on the wake potential.

  11. Exchange corrections in a low-temperature plasma.

    Science.gov (United States)

    Ekman, Robin; Zamanian, Jens; Brodin, Gert

    2015-07-01

    We have studied the exchange corrections to linear electrostatic wave propagation in a plasma using a quantum kinetic formalism. Specifically, we have considered the zero-temperature limit. In order to simplify the calculations we have focused on the long-wavelength limit, i.e., wavelengths much longer than the de Broglie wavelength. For the case of ion-acoustic waves we have calculated the exchange correction both to the damping rate and the real part of the frequency. For Langmuir waves the frequency shift due to exchange effects is found. Our results are compared with the frequency shifts deduced from commonly used exchange potentials which are computed from density-functional theory.

  12. O--H charge exchange in cold, dense, hydrogen plasmas

    International Nuclear Information System (INIS)

    Cohen, S.A.; Dylla, H.F.

    1977-05-01

    It is pointed out that the accidentally resonant charge exchange reaction, O + + H 0 reverse arrows O 0 + H + , is an important mechanism for causing the loss of singly charged oxygen ions from oxygen contaminated hydrogen plasmas. Results of a Monte Carlo simulation are presented which show that the fraction of oxygen lost because of charge exchange exceeds 1 / 3 when the parameters n/sub e/ approx. 10 13 cm -3 , n/sub H//sup o/ approx. 10 11 cm -3 and T/sub e/ approx. 3 eV are attained

  13. A case of thyroid storm with multiple organ failure effectively treated with plasma exchange.

    Science.gov (United States)

    Sasaki, Kazuki; Yoshida, Akira; Nakata, Yukiko; Mizote, Isamu; Sakata, Yasushi; Komuro, Issei

    2011-01-01

    We describe a 48-year-old man with thyroid storm presenting with heart failure. He presented severely impaired left ventricular wall motion and a marked increase in the liver enzymes. He developed disseminated intravascular coagulation on day 2. Due to elevated serum thyroid hormone level, anti-thyroid hormone receptor antibody positivity, and his clinical symptoms, he was diagnosed as thyroid storm due to untreated Graves' disease. His condition did not improve even after 6 days of conventional therapy including steroids. After therapeutic plasma exchange was carried out, his thyroid hormone level decreased markedly. Consequently, his condition recovered gradually, and he was discharged at day 43.

  14. Hemolytic uremic syndrome associated with Plasmodium vivax malaria successfully treated with plasma exchange

    Directory of Open Access Journals (Sweden)

    V S Keskar

    2014-01-01

    Full Text Available We report a case of hemolytic uremic syndrome (HUS in an adult patient with Plasmodium vivax malaria. The patient presented with worsening anemia, persistent thrombocytopenia and acute kidney injury. HUS was diagnosed based on the high serum lactate dehydrogenase, elevated reticulocyte count and presence of schistocytes on peripheral blood smear. Kidney biopsy showed features of thrombotic microangiopathy. Complete hematological remission was achieved after five sessions of therapeutic plasma exchange. Renal function partially recovered and stabilized at discharge. Vivax malaria, generally considered benign, may be rarely associated with HUS.

  15. Bovine plasma protein fractionation by ion exchange chromatography.

    Science.gov (United States)

    Moure, F; Rendueles, M; Díaz, M

    2004-12-01

    An ion exchange chromatography process was developed to separate the main protein fractions of bovine blood plasma using a composite material, Q-HyperD resin, and a gel material, DEAE-Sepharose. The experiments were carried out at semipreparative scale. It was necessary to establish analytical methods of electrophoresis and HPLC to identify the fractionated proteins. Results show that these materials are able to adequately fractionate different protein groups from the raw blood plasma. This method may be used to avoid chemical fractionation using agents such as ethanol or PEG and, thus, decrease protein denaturation of the different fractions to be used for research or pharmaceutical purposes. The Q-HyperD resin presents a better retention capacity for plasma protein than DEAE-Sepharose under the experimental conditions employed.

  16. Guillain - Barre syndrome in a patient with acute myocardial infarction with ventricular septal defect repair treated with plasma exchange

    Directory of Open Access Journals (Sweden)

    Maitrey D Gajjar

    2015-01-01

    Full Text Available Guillain - Barre syndrome (GBS is an acute, frequently severe progressive illness of peripheral nervous system that is autoimmune in nature. GBS after myocardial infarction (MI with ventricular septal defect (VSD is uncommon with high mortality rate if not treated promptly. [1] We report a successful outcome of GBS post MI with VSD in a 60-year-old male patient who was on a ventilator treated successfully with therapeutic plasma exchange.

  17. Charge exchange recombination spectroscopy as a plasma diagnostic tool

    International Nuclear Information System (INIS)

    Fonck, R.J.

    1984-12-01

    Intensity and line profile measurements of the spectra of light hydrogenic ion which are excited by charge exchange reactions with fast neutral atoms are being widely used as diagnostics for fusion plasma research. This technique, which is referred to as charge exchange recombination spectroscopy, allows measurements of the densities of fully stripped impurity ions and particle transport coefficients with only minor uncertainties arising from atomic processes. The excitation of long wavelength transitions in light ions such as He + , C 5+ , and O 7+ allows relatively easy measurements of ion velocity distributions to determine ion temperatures and plasma rotation velocities. Among its advantages for such measurements are the facts that fiber optic coupling between a remote spectrometer and the immediate reactor environment is possible in many cases. The measurement is localized by the intersection region of a neutral beamline and viewing sightline, and intrinsic ions can be used so that injection of potentially perturbing impurities can be avoided. A particularly challenging application of this technique lies in the diagnosis of alpha particles expected to be produced in the present generation of Q approx. = 1 tokamak experiments

  18. Plasma arc pyrolysis of radioactive ion exchange resin

    International Nuclear Information System (INIS)

    Pickles, C.A.; Toguri, J.M.

    1992-01-01

    This paper reports on two ion exchange resins (IRN 77 and IRN 78) which were pyrolysed in a plasma-arc furnace. Both continuous and batch tests were performed. Volume reduction ratios of 10 to 1 and 10 to 3.5 were achieved for IRN 78 and IRN 77 respectively. The product of the resin pyrolysis was a char which contained the radioactive elements such as cobalt. The off-gases consisted of mainly hydrogen and carbon monoxide. There was a relatively small amount of dust in the off-gases. At the present time radioactive ion exchange resign is being kept in storage. The volume of this waste is increasing and it is important that the volume be reduce. The volume reduction ratio should be of the order of ten-to-one. Also, it is required that the radioactive elements can be collected or fixed in a form which could easily be disposed of. Plasma arc treatment offers considerable potential for the processing of the waste

  19. Plasma exchange combining with plasma bilirubin adsorption effectively removes toxic substances and improves liver functions of hepatic failure patients.

    Science.gov (United States)

    Che, X-Q; Li, Z-Q; Chen, Z; Guo, D; Jia, Q-Y; Jiang, S-C; Cai, J

    2018-02-01

    Hepatic failure (HF) is a kind of complex disease characterizing with liver dysfunction and a few clinical complications. Artificial liver support system (ALSS) has been applied to HF patients to improve dysfunctional liver in recent years. This study aims to evaluate therapeutic effects of ALSS approaches, including plasma exchange (PE), plasma diafiltration (PDF) and plasma bilirubin adsorption (PBA), on liver function of HF patients. This study is a retrospective analysis involving 516 patients diagnosed as HF between February 2014 and February 2015. Patients were randomly divided into PE, PDF, PE plus PBA, and PDF plus PBA group. Meanwhile, single-drug group and combined-drug group were also divided. The liver functions, capability of removing toxic substances and coagulation functions were evaluated both pre-treatment and post-treatment. The side effects and hospital improvement rate were also observed post-treatment. Hospital improvement rate achieves to 69.6%. TBIL levels and MELD scores were significantly decreased post-treatment compared to pre-treatment (phigher compared to PE and PDF group (p=0.002, 0.002, respectively). MELD scores were significantly decreased post-treatment compared to pre-treatment in each group (pbetter role in removing toxic substances, improving liver functions of HF patients.

  20. Ion Exchange Resin and Clay Vitrification by Plasma Discharges

    International Nuclear Information System (INIS)

    Diaz A, Laura V.; Pacheco S, Joel O.; Pacheco P, Marquidia; Monroy G, Fabiola; Emeterio H, Miguel; Ramos F, Fidel

    2006-01-01

    The lack of treatment of a low and intermediate level radioactive waste (LILRW) lead us to propose a vitrification process based on a plasma discharge; this technique incorporates LILRW into a matrix glass composed of ceramic clays material. The Mexican Institute of Nuclear Research (ININ), uses an ion exchange resin IRN 150 (styrene-divinilbence copolymer) in the TRIGA MARK III nuclear reactor. The principal objective of this resin is to absorb particles containing heavy metals and low-level radioactive particles. Once the IRN 150 resin filter capacity has been exceeded, it should be replaced and treated as LILRW. In this work, a transferred plasma system was realized to vitrify this resin taking advantage of its high power density, enthalpy and chemical reactivity as well as its rapid quenching and high operation temperatures. In order to characterize the morphological structure of these clay samples, Scanning Electron Microscopy (SEM), X-Ray Diffraction (XRD) and Thermogravimetric analysis (TGA) techniques were applied before and after the plasma treatment

  1. Immobilized enzymes in blood plasma exchangers via radiation grafting

    Science.gov (United States)

    Gombotz, Wayne; Hoffman, Allan; Schmer, Gottfried; Uenoyama, Satoshi

    The enzyme asparaginase was immobilized onto a porous hollow polypropylene (PP) fiber blood plasma exchange device for the treatment of acute lymphocytic leukemia. The devices were first radiation grafted with polymethacrylic acid (poly(MAAc)). This introduces carboxyl groups onto the surface of the fibers. Several variables were studied in the grafting reaction including the effects of solvent type and monomer concentration. The carboxyl groups were activated with N-hydroxy succinimide (NHS) using carbodiimide chemistry. Asparaginase was then covalently immobilized on the activated surfaces. Quantitative relationships were found relating the percent graft to the amount of immobilized enzyme which was active. The enzyme reactor was tested both in vitro and in vivo using a sheep as an animal model.

  2. Bicarbonate sulfate exchange in canalicular rat liver plasma membrane vesicles

    International Nuclear Information System (INIS)

    Meier, P.J.; Valantinas, J.; Hugentobler, G.; Rahm, I.

    1987-01-01

    The mechanism(s) and driving forces for biliary excretion of sulfate were investigated in canalicular rat liver plasma membrane vesicles (cLPM). Incubation of cLPM vesicles in the presence of an inside-to-outside (in, out) bicarbonate gradient but not pH or out-to-in sodium gradients, stimulated sulfate uptake 10-fold compared with the absence of bicarbonate and approximately 2-fold above sulfate equilibrium (overshoot). Initial rates of this bicarbonate gradient-driven [ 35 S]-sulfate uptake were saturable with increasing concentrations of sulfate and could be inhibited by probenecid, N-(4-azido-2-nitrophenyl)-2-aminoethylsulfonate, acetazolamide, furosemide, 4-acetamideo-4'-isothiocyanostilbene-2,2'-disulfonic acid, and 4,4'-diisothiocyanostilbene-2,2'-disulfonic acid (IC 50 , ∼40 μM). Cisinhibition of initial bicarbonate gradient-stimulated sulfate uptake and transstimulation of sulfate uptake in the absence of bicarbonate were observed with sulfate, thiosulfate, and oxalate but not with chloride, nitrate, phosphate, acetate, lactate, glutamate, aspartate, cholate, taurocholate, dehydrocholate, taurodehydrocholate, and reduced or oxidized glutathione. These findings indicate the presence of a sulfate (oxalate)-bicarbonate anion exchange system in canalicular rat liver plasma membranes. These findings support the concept that bicarbonate-sensitive transport system might play an important role in bile acid-independent canalicular bile formation

  3. Plasma Exchange for Renal Vasculitis and Idiopathic Rapidly Progressive Glomerulonephritis: A Meta-analysis

    DEFF Research Database (Denmark)

    Walsh, Michael; Catapano, Fausta; Szpirt, Wladimir

    2010-01-01

    exchange did not differ significantly across the range of baseline serum creatinine values (P = 0.7) or number of plasma exchange treatments (P = 0.8). The RR for end-stage renal disease was 0.64 (95% CI, 0.47-0.88; P = 0.006), whereas the RR for death alone was 1.01 (95% CI, 0.71-1.4; P = 0......BACKGROUND:: Plasma exchange may be effective adjunctive treatment for renal vasculitis. We performed a systematic review and meta-analysis of randomized controlled trials of plasma exchange for renal vasculitis. STUDY DESIGN:: Systematic review and meta-analysis of articles identified from...

  4. Fusion plasma losses due to the charge exchange of injected neutrals

    International Nuclear Information System (INIS)

    Bender, D.J.; Carlson, G.A.

    1975-01-01

    The interaction of a neutral beam, consisting of full, half and third energy components, with a mirror plasma is analyzed. The beam-plasma interaction is assumed to occur via ionization and charge exchange collisions. The plasma was approximated as being spherical in shape, having a uniform density, isotropic velocity distribution, and a mirror plasma energy distribution. It was found that to a first approximation, for plasma energies less than 100 keV, the charge exchange power loss (per injected atom) of the half energy component is at least twice that of the full energy component. For the third energy component, the loss is at least three times that of the full energy component. For some plasma conditions, the neutral beam can act as an energy sink for the plasma due to these charge exchange losses. (U.S.)

  5. Review of low pressure plasma processing of proton exchange membrane fuel cell electrocatalysts

    OpenAIRE

    Brault , Pascal

    2016-01-01

    Review article; International audience; The present review is describing recent advances in plasma deposition and treatment of low temperature proton exchange membrane fuel cells electrocatalysts. Interest of plasma processing for growth of platinum based, non-precious and metal free electrocatalysts is highlighted. Electrocatalysts properties are tentatively correlated to plasma parameters.

  6. Therapeutical approach to plasma homocysteine and cardiovascular risk reduction

    Directory of Open Access Journals (Sweden)

    Marcello Ciaccio

    2008-03-01

    Full Text Available Marcello Ciaccio, Giulia Bivona, Chiara BelliaDepartment of Medical Biotechnologies and Forensic Medicine, Faculty of Medicine, University of Palermo, ItalyAbstract: Homocysteine is a sulfur-containing aminoacid produced during metabolism of methionine. Since 1969 the relationship between altered homocysteine metabolism and both coronary and peripheral atherotrombosis is known; in recent years experimental evidences have shown that elevated plasma levels of homocysteine are associated with an increased risk of atherosclerosis and cardiovascular ischemic events. Several mechanisms by which elevated homocysteine impairs vascular function have been proposed, including impairment of endothelial function, production of reactive oxygen species (ROS and consequent oxidation of low-density lipids. Endothelial function is altered in subjects with hyperhomocysteinemia, and endothelial dysfunction is correlated with plasma levels of homocysteine. Folic acid and B vitamins, required for remethylation of homocysteine to methionine, are the most important dietary determinants of homocysteine and daily supplementation typically lowers plasma homocysteine levels; it is still unclear whether the decreased plasma levels of homocysteine through diet or drugs may be paralleled by a reduction in cardiovascular risk.Keywords: homocysteine, MTHFR, cardiovascular disease, folate, B vitamin

  7. Charge-exchange processes in a divertor plasma with account for excited particles

    International Nuclear Information System (INIS)

    Krasheninnikov, S.I.; Lisitsa, V.S.; Pigarov, A.Yu.

    1988-01-01

    A model describing dynamics of neutral atoms and multicharge ions in tokamak plasma, taking account of cascade excitation effect on charge exchange and ionization processes, is constructed. Dependences of effective rate of processes of proton charge exchange on hydrogen atom and non-resonance helium atom charge exchange on proton and α-particle- on atomic hydrogen on tokamak divertor plasma parameters are calculated. It is shown that H + +He→H-He + charge exchange can make up a notable shave (∼30%) in full helium ionization rate. Accounting for Ge 2+ charge exchange on atomic hydrogen under INTOR reactor divertor plasma conditions can lead to substantial He 2+ →He + conversion and thus increase diverter plate sputtering by helium ions

  8. METHOD FOR EXCHANGING ENERGY WITH A PLASMA BY MAGNETIC PUMPING

    Science.gov (United States)

    Hall, L.S.

    1963-12-31

    A method of heating a plasma confined by a static magnetic field is presented. A time-varying magnetic field having a rise time to a predetermined value substantially less than its fall time is applied to a portion of the plasma. Because of the much shorter rise time, the plasma is reversibly heated. This cycle is repeated until the desired plasma temperature is reached. (AEC)

  9. Plasma exchange in small intestinal transplantation between ABO-incompatible individuals: A case report

    OpenAIRE

    ZHANG, QIUHUI; HU, XINGBIN; XIA, AIJUN; YI, JING; AN, QUNXING; ZHANG, XIANQING

    2013-01-01

    The aim of this study was to investigate the application of plasma exchange in small intestinal transplantation between ABO blood type-incompatible patients. A small intestinal transplantation case between ABO-incompatible individuals is hereby presented and analyzed. The main treatment included plasma exchange, splenectomy and immunosuppression. The patient undergoing small intestinal transplantation exhibited stable vital signs. A mild acute rejection reaction developed ~2 weeks after the s...

  10. Na+/H+ Exchange Activity in the Plasma Membrane of Arabidopsis1

    Science.gov (United States)

    Qiu, Quan-Sheng; Barkla, Bronwyn J.; Vera-Estrella, Rosario; Zhu, Jian-Kang; Schumaker, Karen S.

    2003-01-01

    In plants, Na+/H+ exchangers in the plasma membrane are critical for growth in high levels of salt, removing toxic Na+ from the cytoplasm by transport out of the cell. The molecular identity of a plasma membrane Na+/H+ exchanger in Arabidopsis (SOS1) has recently been determined. In this study, immunological analysis provided evidence that SOS1 localizes to the plasma membrane of leaves and roots. To characterize the transport activity of this protein, purified plasma membrane vesicles were isolated from leaves of Arabidopsis. Na+/H+ exchange activity, monitored as the ability of Na to dissipate an established pH gradient, was absent in plants grown without salt. However, exchange activity was induced when plants were grown in 250 mm NaCl and increased with prolonged salt exposure up to 8 d. H+-coupled exchange was specific for Na, because chloride salts of other monovalent cations did not dissipate the pH gradient. Na+/H+ exchange activity was dependent on Na (substrate) concentration, and kinetic analysis indicated that the affinity (apparent Km) of the transporter for Na+ is 22.8 mm. Data from two experimental approaches supports electroneutral exchange (one Na+ exchanged for one proton): (a) no change in membrane potential was measured during the exchange reaction, and (b) Na+/H+ exchange was unaffected by the presence or absence of a membrane potential. Results from this research provide a framework for future studies into the regulation of the plant plasma membrane Na+/H+ exchanger and its relative contribution to the maintenance of cellular Na+ homeostasis during plant growth in salt. PMID:12805632

  11. Na+/H+ exchange activity in the plasma membrane of Arabidopsis.

    Science.gov (United States)

    Qiu, Quan-Sheng; Barkla, Bronwyn J; Vera-Estrella, Rosario; Zhu, Jian-Kang; Schumaker, Karen S

    2003-06-01

    In plants, Na+/H+ exchangers in the plasma membrane are critical for growth in high levels of salt, removing toxic Na+ from the cytoplasm by transport out of the cell. The molecular identity of a plasma membrane Na+/H+ exchanger in Arabidopsis (SOS1) has recently been determined. In this study, immunological analysis provided evidence that SOS1 localizes to the plasma membrane of leaves and roots. To characterize the transport activity of this protein, purified plasma membrane vesicles were isolated from leaves of Arabidopsis. Na+/H+ exchange activity, monitored as the ability of Na to dissipate an established pH gradient, was absent in plants grown without salt. However, exchange activity was induced when plants were grown in 250 mm NaCl and increased with prolonged salt exposure up to 8 d. H+-coupled exchange was specific for Na, because chloride salts of other monovalent cations did not dissipate the pH gradient. Na+/H+ exchange activity was dependent on Na (substrate) concentration, and kinetic analysis indicated that the affinity (apparent Km) of the transporter for Na+ is 22.8 mm. Data from two experimental approaches supports electroneutral exchange (one Na+ exchanged for one proton): (a) no change in membrane potential was measured during the exchange reaction, and (b) Na+/H+ exchange was unaffected by the presence or absence of a membrane potential. Results from this research provide a framework for future studies into the regulation of the plant plasma membrane Na+/H+ exchanger and its relative contribution to the maintenance of cellular Na+ homeostasis during plant growth in salt.

  12. Charge exchange signatures in x-ray line emission accompanying plasma-wall interaction

    Czech Academy of Sciences Publication Activity Database

    Renner, Oldřich; Dalimier, E.; Liska, R.; Oks, E.; Šmíd, Michal

    2012-01-01

    Roč. 397, č. 1 (2012), s. 1-6 ISSN 1742-6588 R&D Projects: GA ČR GAP205/10/0814; GA ČR GAP208/10/2302; GA AV ČR IAAX00100903 Institutional research plan: CEZ:AV0Z10100523 Keywords : laser-produced plasma * particle jets generation * plasma-wall interaction * x-ray spectroscopy * charge exchange Subject RIV: BL - Plasma and Gas Discharge Physics

  13. Therapeutic drug monitoring by radioimmunoassay: Determination of aminoglycoside antibiotics and vancomycin in plasma

    International Nuclear Information System (INIS)

    Glaubitt, D.; Drechsler, H.J.; Knoch, K.; Siafarikas, K.

    1984-01-01

    Radioimmunoassay of aminoglycoside antibiotics (gentamicin, tobramycin, netilmicin) or vancomycin in plasma may considerably aid to assess their appropriate dosage and, if necessary, to rapidly adjust it to the assumed requirement. Thus the dosage of the antibiotic is kept large enough as to lead to the desired therapeutic result but not as high as to cause side effects. (orig.)

  14. Plasma exchange to remove HIT antibodies: dissociation between enzyme-immunoassay and platelet activation test reactivities.

    Science.gov (United States)

    Warkentin, Theodore E; Sheppard, Jo-Ann I; Chu, F Victor; Kapoor, Anil; Crowther, Mark A; Gangji, Azim

    2015-01-01

    Repeated therapeutic plasma exchange (TPE) has been advocated to remove heparin-induced thrombocytopenia (HIT) IgG antibodies before cardiac/vascular surgery in patients who have serologically-confirmed acute or subacute HIT; for this situation, a negative platelet activation assay (eg, platelet serotonin-release assay [SRA]) has been recommended as the target serological end point to permit safe surgery. We compared reactivities in the SRA and an anti-PF4/heparin IgG-specific enzyme immunoassay (EIA), testing serial serum samples in a patient with recent (subacute) HIT who underwent serial TPE precardiac surgery, as well as for 15 other serially-diluted HIT sera. We observed that post-TPE/diluted HIT sera-when first testing SRA-negative-continue to test strongly positive by EIA-IgG. This dissociation between the platelet activation assay and a PF4-dependent immunoassay for HIT antibodies indicates that patients with subacute HIT undergoing repeated TPE before heparin reexposure should be tested by serial platelet activation assays even when their EIAs remain strongly positive. © 2015 by The American Society of Hematology.

  15. Total Plasma Exchange in Hypertriglyceridemia-Induced Pancreatitis: Case Report and Literature Review

    Directory of Open Access Journals (Sweden)

    Harleen Dehal

    2018-01-01

    Full Text Available Objective. To emphasize the role of apheresis in management of pancreatitis. Methods. The clinical course of a patient admitted for hypertriglyceridemia-induced pancreatitis (HTGP complicated by multiorgan dysfunction is described, who demonstrated dramatic improvement in his clinical status after total plasma exchange (TPE. In addition, the current guidelines for TPE and the alternative treatment options for HTGP are also presented. Results. A patient presenting with pancreatitis associated with severe systemic inflammatory response was admitted to our hospital with an initial triglyceride level of 1181 mg/dL. Given the patient’s worsening clinical condition, he was started on TPE with a rapid fall in his serum TG levels, in turn leading to early clinical recovery. Conclusion. Though various therapeutic options for the treatment of HTGP are described in literature, there are no set guidelines available to tackle this difficult clinical situation. TPE, albeit not very well known in this context, is one of the many therapies available. Though it leads to a rapid, precipitous fall in the TG levels and early symptom resolution, the data about the long-term morbidity as well as the effectiveness of this therapy is still lacking.

  16. Maintenance plasma exchange treatment for muscle specific kinase antibody positive myasthenia gravis patients.

    Science.gov (United States)

    Yamada, Chisa; Teener, James W; Davenport, Robertson D; Cooling, Laura

    2015-10-01

    Anti-muscle specific kinase antibody positive myasthenia gravis (MuSK MG) is often characterized by a relatively severe and progressive course, refractoriness to standard myasthenia gravis (MG) medications, and an increased risk of myasthenic crisis. We report here successful management of three MuSK MG patients using maintenance therapeutic plasma exchange (TPE) treatment for up to 4.5 years. The study was a 5-year retrospective review of all MG patients treated with TPE between 2008 and 2013 at University of Michigan. Inclusion criteria of MuSK MG were positive for anti-MuSK antibodies and a diagnosis of MuSK MG by staff neurologists. Patient data included age, gender, diagnostic testing results, medications, and the dates and response to TPE treatments. A total of 153 MG patients underwent at least one course of TPE between 2008 and 2013. A total of 12 patients (7.8%) were positive for anti-MuSK antibodies. Patients were predominantly female (83.3%) and a median age of onset was 46-years old. Three MuSK MG patients were successfully managed with maintenance TPE. Maintenance TPE may be an effective option for MuSK MG patients. The key of successful maintenance treatment at our institution has been to tailor the TPE frequency for each individual, and to modify the treatment interval in conjunction with medical management. © 2014 Wiley Periodicals, Inc.

  17. Dialyzer-augmented whole blood and plasma exchange for patients with hepatic or hepatorenal failure.

    Science.gov (United States)

    Buselmeier, T J; Merino, G E; Rodrigo, F; Meyer, R M; Bosl, B H; Kjellstrand, C M; Simmons, R L; Najarian, J S

    1975-01-01

    We have utilized new methods of dialyzer-augmented whole blood and plasma exchange tranfusion in the treatment of hepatic coma. The method employs the new fast flow Buselmeier shunt so that the exchange can be done from a peripheral radial artery shunt site rather than a shunt site in a more major vessel, such as the brachial artery. The method employs in-line dialysis of citrated (CPD) blood or plasma to normalize pH, electrolytes, and blood sugar while infusion heparinization decreases heparin requirements. The application of a single roller pump to the administration and withdrawal lines (placed in opposite directions) helps equalize inflow and outflow where whole blood exchange is done while identical opposing pumps accomplish the same with plasma exchange. The administration of albumin and metaraminol bitartate prevents hypotension due to fluid shifts or compartmental venous dilatation. A closed circuit which does not require disconnection throughout the 30- 60-minute whole blood exchange or the 2 1/2-hour plasma exchange decreases the risk of septic contamination to both medical staff and patients.

  18. Guillain-Barre syndrome in a 7-month-old boy successfully applied plasma exchange.

    Science.gov (United States)

    Akarcan, Sanem Eren; İşgüder, Rana; Yılmaz, Ünsal; Ayhan, Yüce; Ceylan, Gökhan; Ağın, Hasan

    2016-02-01

    Despite being the most common cause of acute flaccid paralysis in children Guillain-Barré syndrome has a low incidence under 18 years old, and is even rarer under the age of 2. Established treatment regimens include intravenous immunoglobulin and plasma exchange in older children and adults. However very limited data are available for the efficacy and safety of plasma exchange in infants younger than 12 month-old. This article presents the experience of plasma exchange in the case of 7-month-old boy diagnosed with Guillain-Barré syndrome. A 7-month-old boy was referred to the pediatric intensive care unit with a 10-day history of progressive weakness, feeding difficulty and constipation. He was diagnosed with axonal Guillain-Barré syndrome on the basis of clinical and electromyographical findings. The patient recovered fully with intravenous immunoglobulin and plasma exchange. Plasma exchange may be a safe option in the treatment in infants with Guillain-Barré syndrome as young as 7-month-age. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Plasma exchange in the intensive care unit: Technical aspects and complications.

    Science.gov (United States)

    Lemaire, Aurélie; Parquet, Nathalie; Galicier, Lionel; Boutboul, David; Bertinchamp, Rémi; Malphettes, Marion; Dumas, Guillaume; Mariotte, Eric; Peraldi, Marie-Noëlle; Souppart, Virginie; Schlemmer, Benoit; Azoulay, Elie; Canet, Emmanuel

    2017-12-01

    Data on plasma exchange therapy in the intensive care unit (ICU) setting are scarce. We aimed to describe the technical aspects and the adverse events associated with the procedure in critically ill patients. All adult patients treated by plasma exchange in the medical ICU of the Saint-Louis university hospital between January 1, 2013 and March 31, 2015 were prospectively included. We report on 260 plasma exchange procedures performed in 50 patients. The centrifugation technique was used for 159 (61%) procedures and the filtration technique for the other 101 (39%) procedures. Both techniques had similar efficacy to treat hyperviscosity syndrome (n = 18). Seventy (26.9%) of the 260 plasma exchange procedures were reported with at least one adverse reaction. Centrifugation and filtration techniques had similar rates of adverse reactions (23.9 vs. 31.7%, P = .19). Hypotension was the most reported (n = 21, 8%) and correlates with a low hematocrit before therapy. Most complications were related to allergic reactions to the replacement fluids. Coagulation disorders depended on the type of replacement fluid. The post-exchange fibrinogen level was decreased by 54% [48;66] with albumin 5%, and 4% [-5;17] with plasma frozen within 24 h. Twenty-three (22.8%) of the 101 filtration procedures experienced filter clotting. Filter clotting was associated with a higher volume exchange prescribed when compared to procedures without filter clotting (4600 [4000;5000] ml vs. 3900 [3600;4800] ml, P < .01). Plasma exchange is a relatively safe and generally well-tolerated procedure in the ICU setting. Most adverse events are unpredictable and related to minor allergic reactions. © 2017 Wiley Periodicals, Inc.

  20. A case of severe radiation pneumonitis. A trial of plasma exchange

    International Nuclear Information System (INIS)

    Miyagawa, Tomoko; Mochizuki, Yoshirou; Nakahara, Yasuharu

    2009-01-01

    A 77-year-old man underwent radiotherapy for the squamous cell carcinoma of the right lung. Two months after the 60 Gy/30 fr irradiation was completed, he complained of dyspnea and his chest X-ray showed ground glass opacities and reticular shadows in both lung fields. Severe radiation pneumonitis was diagnosed. Two grams of methylprednisolone did not improve his symptoms and on the next day his hypoxemia worsened. We then tried plasma exchange because of his critical status. His respiratory status improved rapidly after plasma exchange and his chest X-ray showed remarkable improvement 10 days later. We think this case suggests the effectiveness of plasma exchange for severe radiation pneumonitis. (author)

  1. Fabrication of High-Temperature Heat Exchangers by Plasma Spraying Exterior Skins on Nickel Foams

    Science.gov (United States)

    Hafeez, P.; Yugeswaran, S.; Chandra, S.; Mostaghimi, J.; Coyle, T. W.

    2016-06-01

    Thermal-sprayed heat exchangers were tested at high temperatures (750 °C), and their performances were compared to the foam heat exchangers made by brazing Inconel sheets to their surface. Nickel foil was brazed to the exterior surface of 10-mm-thick layers of 10 and 40 PPI nickel foam. A plasma torch was used to spray an Inconel coating on the surface of the foil. A burner test rig was built to produce hot combustion gases that flowed over exposed face of the heat exchanger. Cooling air flowed through the foam heat exchanger at rates of up to 200 SLPM. Surface temperature and air inlet/exit temperature were measured. Heat transfer to air flowing through the foam was significantly higher for the thermally sprayed heat exchangers than for the brazed heat exchangers. On an average, thermally sprayed heat exchangers show 36% higher heat transfer than conventionally brazed foam heat exchangers. At low flow rates, the convective resistance is large (~4 × 10-2 m2 K/W), and the effect of thermal contact resistance is negligible. At higher flow rates, the convective resistance decreases (~2 × 10-3 m2 K/W), and the lower contact resistance of the thermally sprayed heat exchanger provides better performance than the brazed heat exchangers.

  2. Plasma Exchange for the Treatment of Transient Extreme Hypertriglyceridemia Associated with Diabetic Ketoacidosis and Acute Pancreatitis

    Directory of Open Access Journals (Sweden)

    Davide Donelli

    2018-03-01

    Full Text Available Diabetic ketoacidosis (DKA can quite frequently present in association with acute pancreatitis (AP caused by transient severe hypertriglyceridemia (HTG. Here we report the case of a patient presenting with DKA, severe HTG and AP who received urgent plasma exchange for HTG control, and who reached adequate serum triglyceride levels only after appropriate DKA management. The treatment of patients presenting with DKA and coexistent AP associated with severe HTG should focus first on appropriate DKA management. Plasma exchange as a treatment for severe HTG in patients with DKA and AP should be evaluated carefully.

  3. Severe Leptospirosis with Multiple Organ Failure Successfully Treated by Plasma Exchange and High-Volume Hemofiltration

    Directory of Open Access Journals (Sweden)

    Vincent Bourquin

    2011-01-01

    Full Text Available Background. Leptospirosis is a spirochetal zoonosis with complex clinical features including renal and liver failure. Case report. We report the case of a Swiss fisherman presenting with leptospirosis. After initial improvement, refractory septic shock and severe liver and kidney failure developed. The expected mortality was estimated at 90% with clinical scores. The patient underwent plasma exchanges and high-volume hemofiltration (HVHF with complete recovery of hepatic and kidney functions. Discussion. Plasma exchanges and HVHF may confer survival benefit on patients with severe leptospirosis, refractory septic shock, and multiple-organ failure.

  4. Plasma exchange in Immunoglobulin A nephropathy with thrombotic microangiopathy and acute cortical necrosis

    Directory of Open Access Journals (Sweden)

    P Doddi

    2016-01-01

    Full Text Available A 25-year-old female presented with decreased urine output, deranged renal function, thrombocytopenia, and hemolytic anemia. Kidney biopsy was consistent with thrombotic microangiopathy with acute cortical necrosis and Immunoglobulin A nephropathy (IgAN. Hemolytic anemia, thrombocytopenia and urine output improved after five sessions of plasma exchange. Renal function showed a delayed recovery and serum creatinine normalized by 3 months. This is first case of successful use of plasma exchange in hemolytic uremic syndrome with cortical necrosis associated with IgAN.

  5. Shape of the Hα emission line in non resonant charge exchange in hydrogen plasmas

    International Nuclear Information System (INIS)

    Susino Bueno, A.; Zurro Hernandez, B.

    1977-01-01

    The Hα line shape emitted from a maxwellian hydrogen plasma and produced by non resonant change exchange has been calculated. Its explicit shape depends on the ion temperature, on background neutral energy and on the relative shape of the collision cross section. A comparison between theoretical and experimental shapes of the Hα line is carried out to check the model and to deduce the ion plasma temperature. (author) [es

  6. A Study of Charge-Exchange Neutrals from a Rotating Plasma

    DEFF Research Database (Denmark)

    Jørgensen, L. W.; Sillesen, Alfred Hegaard

    1980-01-01

    Measurements of charge-exchange neutrals leaving a rotating plasma (a puffatron device) are reported. Neutrals are observed only during the breakdown phase (2-3 mu s) indicating that the created plasma is fully ionized. Several energy spectra of the neutrals for different plasma parameters are ob....... Neutral particle measurements at different distances from the puffatron midplane show ionization velocities parallel with the magnetic field of about 2*104 ms-1 and plasma expansion velocities of about 5-6*104 ms-1 corresponding to an electron temperature of about 25 eV.......Measurements of charge-exchange neutrals leaving a rotating plasma (a puffatron device) are reported. Neutrals are observed only during the breakdown phase (2-3 mu s) indicating that the created plasma is fully ionized. Several energy spectra of the neutrals for different plasma parameters...... are obtained. These spectra are grossly explained using a single-particle orbit model of the plasma ions. Assuming a Maxwellian distribution for the spread in the ion Larmor energy for the central part of the measured energy spectra, it is possible to determine the ion energy during the breakdown phase...

  7. Effect of exchange correlation potential on dispersion properties of lower hybrid wave in degenerate plasma

    Science.gov (United States)

    Rimza, Tripti; Sharma, Prerana

    2017-05-01

    The dispersion properties of lower hybrid wave are studied in electron-iondegenerate plasma with exchange effect in non-relativistic regime. It is found that the combined effect of Bohm potential and exchange correlation potential significantly modifies the dispersion properties of lower hybrid wave. The graphical results explicitly show the influence of degeneracy pressure, Bohm force and exchange correlation potential on the frequency of the lower hybrid mode. Present work should be of relevance for the dense astrophysical environments like white dwarfs and for laboratory experiments.

  8. Predicted and observed therapeutic dose exceedances of ionizable pharmaceuticals in fish plasma from urban coastal systems.

    Science.gov (United States)

    Scott, W Casan; Du, Bowen; Haddad, Samuel P; Breed, Christopher S; Saari, Gavin N; Kelly, Martin; Broach, Linda; Chambliss, C Kevin; Brooks, Bryan W

    2016-04-01

    Instream flows of the rapidly urbanizing watersheds and estuaries of the Gulf of Mexico in Texas (USA) are increasingly dominated by reclaimed waters. Though ionizable pharmaceuticals have received increasing attention in freshwaters, many research questions remain unanswered, particularly in tidally influenced urban coastal systems, which experience significant spatiotemporal variability in pH that influences bioavailability and bioaccumulation. The authors coupled fish plasma modeling of therapeutic hazard values with field monitoring of water chemistry variability and pharmaceutical occurrence to examine whether therapeutic hazards to fish existed within these urban coastal ecosystems and whether therapeutic hazards differed within and among coastal locations and seasons. Spatial and temporal fluctuations in pH within study sites altered the probability of encountering pharmaceutical hazards to fish. Significant water quality differences were consistently observed among traditional parameters and pharmaceuticals collected from surface and bottom waters, which are rarely sampled during routine surface water quality assessments. The authors then compared modeling predictions of fish plasma concentrations of pharmaceuticals to measured plasma levels from various field-collected fish species. Diphenhydramine and diltiazem were observed in plasma of multiple species, and diltiazem exceeded human therapeutic doses in largemouth bass, catfish, and mullet inhabiting these urban estuaries. Though the present study only examined a small number of target analytes, which represent a microcosm of the exposome of these fish, coastal systems are anticipated to be more strongly influenced by continued urbanization, altered instream flows, and population growth in the future. Unfortunately, aquatic toxicology information for diltiazem and many other pharmaceuticals is not available for marine and estuarine organisms, but such field observations suggest that potential adverse

  9. Cell death induced by ozone and various non-thermal plasmas: therapeutic perspectives and limitations

    Czech Academy of Sciences Publication Activity Database

    Lunov, Oleg; Zablotskyy, Vitaliy A.; Churpita, Olexandr; Chánová, Eliška; Syková, Eva; Dejneka, Alexandr; Kubinová, Šárka

    2014-01-01

    Roč. 4, NOV (2014), "7129-1"-"7129-11" ISSN 2045-2322 R&D Projects: GA MŠk LO1309 Grant - others:AV ČR(CZ) M100101219 Institutional support: RVO:68378271 ; RVO:61389013 ; RVO:68378041 Keywords : cell death * non-thermal plasma * therapeutic perspectives Subject RIV: BO - Biophysics; FH - Neurology (UEM-P); CD - Macromolecular Chemistry (UMCH-V) Impact factor: 5.578, year: 2014

  10. The effect of charge exchange with neutral deuterium on carbon emission in JET divertor plasmas

    International Nuclear Information System (INIS)

    Maggi, C.; Horton, L.; Summers, H.

    1999-11-01

    High density, low temperature divertor plasma operation in tokamaks results in large neutral deuterium concentrations in the divertor volume. In these conditions, low energy charge transfer reactions between neutral deuterium and the impurity ions can in principle enhance the impurity radiative losses and thus help to reduce the maximum heat load to the divertor target. A quantitative study of the effect of charge exchange on carbon emission is presented, applied to the JET divertor. Total and state selective effective charge exchange recombination rate coefficients were calculated in the collisional radiative picture. These coefficients were coupled to divertor and impurity transport models to study the effect of charge exchange on the measured carbon spectral emission in JET divertor discharges. The sensitivity of the effect of charge exchange to the assumptions in the impurity transport model was also investigated. A reassessment was made of fundamental charge exchange cross section data in support of this study. (author)

  11. Nano-diamonds surface modifications: understanding of electron exchange mechanisms and evidence of a therapeutic effect

    International Nuclear Information System (INIS)

    Petit, Tristan

    2013-01-01

    In this thesis, a therapeutic effect of nano-diamonds (NDs) has been evidenced by investigating the role of NDs surface chemistry on their electronic properties. More precisely, the generation of reactive oxygen species from detonation NDs under ionizing radiation, which could improve current radiotherapy treatments, has been demonstrated. To this end, surface treatments facilitating electron transfer from NDs to their environment, namely hydrogenation and surface graphitization, were developed. Experimental conditions ensuring an efficient hydrogenation by hydrogen plasma were determined under ultrahigh vacuum, before being used to prepare large quantities of NDs in powder phase. A similar procedure was applied to the surface graphitization of NDs, performed by annealing under vacuum at high temperature. The impact of such surface treatments on the electronic interaction properties of NDs has been investigated under ambient air and after dispersion in water. These surface treatments induce a positive Zeta potential to NDs in water, which origin has been discussed. Finally, their interactions with human tumor cells were observed. Radiosensitization of tumor cells using NDs under gamma irradiation was demonstrated, opening new perspectives for NDs in nano-medicine. (author) [fr

  12. Successful use of plasma exchange for profound hemolysis in a child with loxoscelism.

    Science.gov (United States)

    Said, Ahmed; Hmiel, Paul; Goldsmith, Matthew; Dietzen, Dennis; Hartman, Mary E

    2014-11-01

    We describe a 6-year-old boy who presented with massive hemolysis, shock, disseminated intravascular coagulopathy, and acute renal failure after loxosceles envenomation. In this patient, plasma exchange therapy (PEX) successfully cleared the plasma from an initial hemolytic index of 2000 (equivalent to 2 g/dL hemoglobin, where optimetric laboratory evaluation is impossible) to an index of impossible. In this setting, PEX can be used to clear the plasma, restoring the ability to perform routine laboratory assessments. Copyright © 2014 by the American Academy of Pediatrics.

  13. Charge-exchange-induced formation of hollow atoms in high-intensity laser-produced plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Rosmej, F.B. [TU-Darmstadt, Institut fuer Kernphysik, Darmstadt (Germany); Faenov, A.Ya.; Pikuz, T.A.; Magunov, A.I.; Skobelev, I.Yu. [Multicharged Ions Spectra Data Center of VNIIFTRI, Mendeleevo (Russian Federation); Auguste, T.; D' Oliveira, P.; Hulin, S.; Monot, P. [Commissariat a lEnergie Atomique DSM/DRECAM/SPAM, Gif-Sur-Yvette Cedex (France); Andreev, N.E.; Chegotov, M.V.; Veisman, M.E. [High Energy Density Research Centre, Institute of High Temperatures of Russian Academy of Sciences, Moscow (Russian Federation)

    1999-03-14

    For the first time registration of high-resolution soft x-ray emission and atomic data calculations of hollow-atom dielectronic satellite spectra of highly charged nitrogen have been performed. Double-electron charge-exchange processes from excited states are proposed for the formation of autoionizing levels nln'l' in high-intensity laser-produced plasmas, when field-ionized ions penetrate into the residual gas. Good agreement is found between theory and experiment. Plasma spectroscopy with hollow ions is proposed and a temperature diagnostic for laser-produced plasmas in the long-lasting recombining regime is developed. (author). Letter-to-the-editor.

  14. Plasma exchange in antineutrophil cytoplasmic antibody-associated vasculitis--a 25-year perspective

    DEFF Research Database (Denmark)

    Szpirt, Wladimir M

    2015-01-01

    Demonstration of a pathogenic role for antineutrophil cytoplasmic antibodies (ANCA) underlies the scientific rationale for plasma exchange (PLEX) in the treatment of ANCA-associated vasculitis (AAV). Most clinical evidence of efficacy concerns the use of PLEX for the recovery of renal function...

  15. Plasma-polymerized alkaline anion-exchange membrane: Synthesis and structure characterization

    International Nuclear Information System (INIS)

    Hu Jue; Meng Yuedong; Zhang Chengxu; Fang Shidong

    2011-01-01

    After-glow discharge plasma polymerization was developed for alkaline anion-exchange membranes synthesis using vinylbenzyl chloride as monomer. X-ray photoelectron spectroscopy and attenuated total reflection Fourier transform infrared spectroscopy were used to characterize the chemical structure properties of plasma-polymerized membranes. Ion-exchange capacities of quaternized poly(vinylbenzyl chloride) (QPVBC) membranes were measured to evaluate their capability of hydroxyl ion transport. A mechanism of plasma polymerization using VBC as monomer that accounts for the competitive effects of free radicals polymerization and plasma ablation in the plasma polymerization process was proposed. Our results indicate that plasma discharge power influences the contents of functional groups and the structure of the plasma polymer membranes, which attribute to the coactions of polymerization and ablation. The properties of uniform morphology, good adhesion to the substrate, high thermal stability and satisfying anion conduction level suggest the potential application of QPVBC membrane deposited at discharge power of 20 W in alkaline direct methanol fuel cells.

  16. Ozone dosing alters the biological potential and therapeutic outcomes of plasma rich in growth factors.

    Science.gov (United States)

    Anitua, E; Zalduendo, M M; Troya, M; Orive, G

    2015-04-01

    Until now, ozone has been used in a rather empirical way. This in-vitro study investigates, for the first time, whether different ozone treatments of plasma rich in growth factors (PRGF) alter the biological properties and outcomes of this autologous platelet-rich plasma. Human plasma rich in growth factors was treated with ozone using one of the following protocols: a continuous-flow method; or a syringe method in which constant volumes of ozone and PRGF were mixed. In both cases, ozone was added before, during and after the addition of calcium chloride. Three ozone concentrations, of the therapeutic range 20, 40 and 80 μg/mL, were tested. Fibrin clot properties, growth factor content and the proliferative effect on primary osteoblasts and gingival fibroblasts were evaluated. Ozone treatment of PRGF using the continuous flow protocol impaired formation of the fibrin scaffold, drastically reduced the levels of growth factors and significantly decreased the proliferative potential of PRGF on primary osteoblasts and gingival fibroblasts. In contrast, treatment of PRGF with ozone using the syringe method, before, during and after the coagulation process, did not alter the biological outcomes of the autologous therapy. These findings suggest that ozone dose and the way that ozone combines with PRGF may alter the biological potential and therapeutic outcomes of PRGF. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Robustness of solvent/detergent treatment of plasma derivatives: a data collection from Plasma Protein Therapeutics Association member companies.

    Science.gov (United States)

    Dichtelmüller, Herbert O; Biesert, Lothar; Fabbrizzi, Fabrizio; Gajardo, Rodrigo; Gröner, Albrecht; von Hoegen, Ilka; Jorquera, Juan I; Kempf, Christoph; Kreil, Thomas R; Pifat, Dominique; Osheroff, Wendy; Poelsler, Gerhard

    2009-09-01

    Solvent/detergent (S/D) treatment is an established virus inactivation technology that has been applied in the manufacture of medicinal products derived from human plasma for more than 20 years. Data on the inactivation of enveloped viruses by S/D treatment collected from seven Plasma Protein Therapeutics Association member companies demonstrate the robustness, reliability, and efficacy of this virus inactivation method. The results from 308 studies reflecting production conditions as well as technical variables significantly beyond the product release specification were evaluated for virus inactivation, comprising different combinations of solvent and detergent (tri(n-butyl) phosphate [TNBP]/Tween 80, TNBP/Triton X-100, TNBP/Na-cholate) and different products (Factor [F]VIII, F IX, and intravenous and intramuscular immunoglobulins). Neither product class, process temperature, protein concentration, nor pH value has a significant impact on virus inactivation. A variable that did appear to be critical was the concentration of solvent and detergent. The data presented here demonstrate the robustness of virus inactivation by S/D treatment for a broad spectrum of enveloped test viruses and process variables. Our data substantiate the fact that no transmission of viruses such as human immunodeficiency virus, hepatitis B virus, hepatitis C virus, or of other enveloped viruses was reported for licensed plasma derivatives since the introduction of S/D treatment.

  18. DBD plasma source operated in single-filamentary mode for therapeutic use in dermatology

    Energy Technology Data Exchange (ETDEWEB)

    Rajasekaran, Priyadarshini; Mertmann, Philipp; Bibinov, Nikita; Awakowicz, Peter [Institute for Electrical Engineering and Plasma Technology, Ruhr-Universitaet Bochum, Universitaetsstr. 150, 44801 Bochum (Germany); Wandke, Dirk [CINOGY GmbH, Max-Naeder-Str. 15, 37114 Duderstadt (Germany); Vioel, Wolfgang, E-mail: rajasekaran@aept.rub.d, E-mail: mertmann@aept.rub.d, E-mail: Nikita.Bibinov@rub.d, E-mail: dirk.wandke@cinogy.co, E-mail: vioel@hawk-hhg.d, E-mail: awakowicz@aept.rub.d [University of Applied Sciences and Arts, Faculty of Natural Sciences and Technology, Von-Ossietzky-Str. 99, 37085 Goettingen (Germany)

    2009-11-21

    Our dielectric barrier discharge (DBD) plasma source for bio-medical application comprises a copper electrode covered with ceramic. Objects of high capacitance such as the human body can be used as the opposite electrode. In this study, the DBD source is operated in single-filamentary mode using an aluminium spike as the opposite electrode, to imitate the conditions when the discharge is ignited on a raised point, such as hair, during therapeutic use on the human body. The single-filamentary discharge thus obtained is characterized using optical emission spectroscopy, numerical simulation, voltage-current measurements and microphotography. For characterization of the discharge, averaged plasma parameters such as electron distribution function and electron density are determined. Fluxes of nitric oxide (NO), ozone (O{sub 3}) and photons reaching the treated surface are simulated. The calculated fluxes are finally compared with corresponding fluxes used in different bio-medical applications.

  19. Successful therapy with hemoperfusion and plasma exchange in acute 1,2,3-trichloropropane poisoning.

    Science.gov (United States)

    Liu, P; Liang, Y-G; Meng, Q-Y; Zhang, C-G; Wang, H-C; Zhang, X-G; Li, G; Liu, Z-Y; He, Y-Z

    2012-05-01

    1,2,3-trichloropropane (1,2,3-TCP) is commonly used as an intermediate in pesticide and an industrial specialty solvent. Acute 1,2,3-TCP poisoning is rare but a medical emergency. Sporadic cases of toxic hepatic injury from 1,2,3-TCP in humans have been reported. Liver is a target organ for 1,2,3-TCP toxicity, which may ensue in a short period after ingestion. A specific antidote against 1,2,3-TCP is not available. So it is important to distinguish that a patient with 1,2,3-TCP poisoning constitutes a medical emergency. In this case study, the poisoned patient's clinical condition and laboratory values improved gradually after she received hemoperfusion (HP) and plasma exchange, which indicated that the therapy with HP and plasma exchange were helpful in the treatment of 1,2,3-TCP poisoning.

  20. A Rare case of Guillain-Barré syndrome in pregnancy treated with plasma exchange

    Directory of Open Access Journals (Sweden)

    Rahul Vasudev

    2014-01-01

    Full Text Available Guillain-Barre syndromé (GBS is an autoimmune disorder. It is rare in pregnancy as there is a decrease in cell-mediated immunity. A case of 28-year-old pregnant woman who presented with acute flaccid quadriplegia suffering from GBS is discussed in this study. She was treated with plasma exchange in her immediate post-partum period. The management of GBS in pregnancy has been discussed.

  1. Shear Alfvén Wave with Quantum Exchange-Correlation Effects in Plasmas

    Science.gov (United States)

    Mir, Zahid; Jamil, M.; Rasheed, A.; Asif, M.

    2017-09-01

    The dust shear Alfvén wave is studied in three species dusty quantum plasmas. The quantum effects are incorporated through the Fermi degenerate pressure, tunneling potential, and in particular the exchange-correlation potential. The significance of exchange-correlation potential is pointed out by a graphical description of the dispersion relation, which shows that the exchange potential magnifies the phase speed. The low-frequency shear Alfvén wave is studied while considering many variables. The shear Alfvén wave gains higher phase speed at the range of small angles for the upper end of the wave vector spectrum. The increasing dust charge and the external magnetic field reflect the increasing tendency of phase speed. This study may explain many natural mechanisms associated with long wavelength radiations given in the summary.

  2. Plasmon dispersion and dynamic exchange-correlation potential from two-pair excitations in degenerate plasmas

    International Nuclear Information System (INIS)

    Boehm, H.M.; Conti, S.; Tosi, M.P.

    1995-11-01

    Electron energy loss experiments have shown a rapid softening of the bulk plasmon dispersion across the series of the alkali metals. Motivated by these observations, we reconsider the evaluation of the dynamic, long-wavelength exchange-correlation potential f xc (ω) in the electron fluid, which is of interest for applications in time-dependent density functional theory. The value of Re[f xc (ω pl )] at the plasma frequency ω pl determines the exchange-correlation contribution to the leading plasmon dispersion coefficient in the homogeneous electron fluid. Whereas an interpolation scheme originally proposed by Gross and Kohn assumes a monotonic increase of Re[f xc (ω) - f xc (0)] across the plasma frequency, we examine the possibility of strongly non-monotonic behaviour arising from a resonance process between plasmons and two-pair excitations. This process is evaluated with the help of sum rules and selfconsistency requirements with a single-pole approximation of the dielectric function. The cases of a fermion plasma and of a boson plasma are treated in parallel and the reliability of the results for the fermion plasma at low coupling is tested by calculations within a random phase approximation for the dielectric function. In all cases it is found that the resonance process accumulates oscillator strength in the neighbourhood of 2ω pl , thus decreasing the value of Re[f xc (ω pl )] below the static value f xc (0) fixed by the compressibility sum rule. Although this lowering does not suffice to account by itself for the measured plasmon dispersion coefficient in the low-density alkali metals, our results provide useful input for combined band-structure and exchange-correlation calculations. (author). 40 refs, 9 figs, 2 tabs

  3. [Relation between dose, plasma concentration and therapeutic effect of theophylline in children with sleep apnea].

    Science.gov (United States)

    Rodríguez-Palomares, C; Ugartechea, J C; Palma-Aguirre, J A; Juárez-Olguín, H; Calderón-Mandujano, B

    1989-12-01

    The plasma concentration of theophylline was determined in twelve children with infantile sleep apnea (average age 48.5 days). The purpose of the study was to correlate concentrations with the dosages given, the therapeutic response and any adverse effects which could arise. In addition, other pharmacokinetic values were found, half-life (t 1/2) and clearance concentrations (Clss). The oral maintenance dose used was 4 mg/kg/24 h. The serum concentration of theophylline was determined by a homogeneous immunoassay enzyme technique (EMIT). A bad correlation was found (r = 0.45) between the oral dosage given and the plasma concentrations found. This was probably due to variations in the clearance of the drug. Yet, plasma concentrations fell between 3.0 and 12.6 micrograms/mL, enough to satisfactorily control apneic episodes in all the children included in the study without undesirable side-effects. Only one patient had some trouble in falling asleep and showed signs of irritability. The half-life was 13.30 +/- 7.46 hours and Clss was 36.64 +/- 12.98 mL/h/kg. In general, our results correlate with those reported in the literature. The accuracy of the pharmacokinetic parameters with two samples is reliable, therefore avoiding the use of multiple sampling in this group of children.

  4. Formation of vertically aligned carbon nanostructures in plasmas: numerical modelling of growth and energy exchange

    Energy Technology Data Exchange (ETDEWEB)

    Denysenko, I; Azarenkov, N A, E-mail: idenysenko@yahoo.com [School of Physics and Technology, V N Karazin Kharkiv National University, 4 Svobody sq., 61077 Kharkiv (Ukraine)

    2011-05-04

    Results on modelling of the plasma-assisted growth of vertically aligned carbon nanostructures and of the energy exchange between the plasma and the growing nanostructures are reviewed. Growth of carbon nanofibres and single-walled carbon nanotubes is considered. Focus is made on studies that use the models based on mass balance equations for species, which are adsorbed on catalyst nanoparticles or walls of the nanostructures. It is shown that the models can be effectively used for the study and optimization of nanostructure growth in plasma-enhanced chemical vapour deposition. The results from these models are in good agreement with the available experimental data on the growth of nanostructures. It is discussed how input parameters for the models may be obtained.

  5. Plasma C-type natriuretic peptide as a predictor for therapeutic response to metoprolol in children with postural tachycardia syndrome.

    Directory of Open Access Journals (Sweden)

    Jing Lin

    Full Text Available POTS is a global public-health disease, but predictor for therapeutic response to metoprolol in children with POTS is lacking. This study was designed to investigate predictive value of plasma C-type natriuretic peptide (CNP in the therapeutic efficacy of metoprolol on postural tachycardia syndrome (POTS in children. Totally 34 children with POTS and 27 healthy children were included in the study. The head-up test or head-up tilt test was used to check heart rate and blood pressure from supine to upright in subjects. A double antibody (competitive sandwich immunoluminometric assay was used to detect plasma CNP. Metoprolol was used to treat children with POTS. The difference in plasma concentrations of CNP between responders and non-responders was compared. An ROC curve was used to analyze plasma CNP to predict efficacy of metoprolol on POTS in children. Plasma CNP in children with POTS was significantly higher than that of healthy children [(51.9 ± 31.4 vs. (25.1 ± 19.1 pg/ml, P 32.55 pg/ml yielded a sensitivity of 95.8% and specificity of 70% in predicting therapeutic efficacy of metoprolol on POTS children. Plasma CNP might serve as a useful predictor for the therapeutic efficacy of metoprolol on POTS in children.

  6. Therapeutic IgG4 antibodies engage in Fab-arm exchange with endogenous human IgG4 in vivo

    NARCIS (Netherlands)

    Labrijn, Aran F.; Buijsse, Antonio Ortiz; van den Bremer, Ewald T. J.; Verwilligen, Annemiek Y. W.; Bleeker, Wim K.; Thorpe, Susan J.; Killestein, Joep; Polman, Chris H.; Aalberse, Rob C.; Schuurman, Janine; van de Winkel, Jan G. J.; Parren, Paul W. H. I.

    Two humanized IgG4 antibodies, natalizumab and gemtuzumab, are approved for human use, and several others, like TGN1412, are or have been in clinical development. Although IgG4 antibodies can dynamically exchange half-molecules(1), Fab-arm exchange with therapeutic antibodies has not been

  7. Therapeutic IgG4 antibodies engage in Fab-arm exchange with endogenous human IgG4 in vivo

    NARCIS (Netherlands)

    Labrijn, Aran F.; Buijsse, Antonio Ortiz; van den Bremer, Ewald T. J.; Verwilligen, Annemiek Y. W.; Bleeker, Wim K.; Thorpe, Susan J.; Killestein, Joep; Polman, Chris H.; Aalberse, Rob C.; Schuurman, Janine; van de Winkel, Jan G. J.; Parren, Paul W. H. I.

    2009-01-01

    Two humanized IgG4 antibodies, natalizumab and gemtuzumab, are approved for human use, and several others, like TGN1412, are or have been in clinical development. Although IgG4 antibodies can dynamically exchange half-molecules, Fab-arm exchange with therapeutic antibodies has not been demonstrated

  8. Plasma exchange for induction and cyclosporine A for maintenance of remission in Wegener's granulomatosis--a clinical randomized controlled trial

    DEFF Research Database (Denmark)

    Szpirt, Wladimir M; Heaf, James G; Petersen, Jørgen

    2011-01-01

    The use of plasma exchange (PE) for induction treatment of anti-neutrophil cytoplasm autoantibody (ANCA)-associated vasculitis (AAV), including Wegener's granulomatosis (WG), is still controversial. The use of PE in AAV is not commonly accepted in patients with a plasma creatinine...

  9. Increased Plasma Colloid Osmotic Pressure Facilitates the Uptake of Therapeutic Macromolecules in a Xenograft Tumor Model

    Directory of Open Access Journals (Sweden)

    Matthias Hofmann

    2009-08-01

    Full Text Available Elevated tumor interstitial fluid pressure (TIFP is a characteristic of most solid tumors. Clinically, TIFP may hamper the uptake of chemotherapeutic drugs into the tumor tissue reducing their therapeutic efficacy. In this study, a means of modulating TIFP to increase the flux of macromolecules into tumor tissue is presented, which is based on the rationale that elevated plasma colloid osmotic pressure (COP pulls water from tumor interstitium lowering the TIFP. Concentrated human serum albumin: (20% HSA, used as an agent to enhance COP, reduced the TIFP time-dependently from 8 to 2 mm Hg in human tumor xenograft models bearing A431 epidermoid vulva carcinomas. To evaluate whether this reduction facilitates the uptake of macromolecules, the intratumoral distribution of fluorescently conjugated dextrans (2.5 mg/ml and cetuximab (2.0 mg/ml was probed using novel time domain nearinfrared fluorescence imaging. This method permitted discrimination and semiquantification of tumor-accumulated conjugate from background and unspecific probe fluorescence. The coadministration of 20% HSA together with either dextrans or cetuximab was found to lower the TIFP significantly and increase the concentration of the substances within the tumor tissue in comparison to control tumors. Furthermore, combined administration of 20%HSA plus cetuximab reduced the tumor growth significantly in comparison to standard cetuximab treatment. These data demonstrate that increased COP lowers the TIFP within hours and increases the uptake of therapeutic macromolecules into the tumor interstitium leading to reduced tumor growth. This model represents a novel approach to facilitate the delivery of therapeutics into tumor tissue, particularly monoclonal antibodies.

  10. Silenced uses and moral ideals in the exchange of Danish blood and plasma

    DEFF Research Database (Denmark)

    Sheikh, Zainab Afshan; Deleuran, Ida; Hoeyer, Klaus

    2016-01-01

    This article explores the interplay between cultural discourses, moral reasoning and silenced uses in the international exchange of Danish blood plasma. Campaigns, policymakers, health professionals working in the blood banks – and even donors – consistently refer to ideals portraying blood....... However, we find that available cultural discourses poorly capture the moral reasoning among many donors. In fact, when informed about the existing forms of tender, plasma trade sounds like a good idea to most of them. Furthermore, they are not particularly interested in information. We argue...... that the silencing of trade is infusing the system with an unnecessary vulnerability that could easily be avoided with a different communication strategy towards donors. To arrive at new and better strategies, however, one must move beyond the immediate words and reactions of donors contemplating trade and seek...

  11. Absorption kinetics and steady-state plasma concentrations of theophylline following therapeutic doses of two sustained-release preparations

    DEFF Research Database (Denmark)

    Andersen, O; Nielsen, M K; Eriksen, P B

    1983-01-01

    Ten healthy volunteers received two sustained-release preparations as a single and multiple dose regimen in an open crossover study. Plasma theophylline concentrations were measured by an enzyme immunoassay. The limited fluctuation of the theophylline levels at steady state, with twice daily...... formulation, whereas this was not the case for the other (r = 0.27 and 0.49). The daily dose necessary to keep the plasma concentration within the therapeutic range of 55-110 mumole/liter varied from 7.9 to 22.9 mg/kg. Only mild side effects were recorded, but they were not correlated to the plasma...... theophylline concentration....

  12. Plasma microRNAs serve as biomarkers of therapeutic efficacy and disease progression in hypertension-induced heart failure

    NARCIS (Netherlands)

    Dickinson, Brent A; Semus, Hillary M; Montgomery, Rusty L; Stack, Christianna; Latimer, Paul A; Lewton, Steven M; Lynch, Joshua M; Hullinger, Thomas G; Seto, Anita G; van Rooij, Eva

    AIMS: Recent studies have shown that microRNAs (miRNAs), besides being potent regulators of gene expression, can additionally serve as circulating biomarkers of disease. The aim of this study is to determine if plasma miRNAs can be used as indicators of disease progression or therapeutic efficacy in

  13. Successful plasma exchange combined with rituximab therapy in aggressive APS-related cutaneous necrosis.

    Science.gov (United States)

    Costa, Rubens; Fazal, Salman; Kaplan, Robert B; Spero, Joel; Costa, Ricardo

    2013-03-01

    Antiphospholipid antibody syndrome (APS) is a systemic autoimmune disorder characterized by venous and/or arterial thrombosis or recurrent fetal loss associated with the presence of antiphospholipid antibodies and/or a lupus anticoagulant. The skin appears to be an important target organ and many cases of APS may present with skin manifestations. These lesions may be manifold and may take the form of livedo reticularis, livedo racemosa, ulcerations, digital gangrene, subungeal splinter hemorrhages, superficial venous thrombosis, thrombocytopenic purpura, pseudovasculitic manifestations, extensive cutaneous necrosis, or primary anetoderma. We report a case of fulminant APS-related cutaneous necrosis. A 38-year-old Caucasian male with a past history of APS, multiple deep vein thrombi/pulmonary emboli, presented with necrotic lesions on his right upper and right lower extremities. Initially, baseline anticoagulation was increased without improvement. Subsequently, plasma exchange was initiated on a daily schedule. Furthermore, rituximab 1,000 mg IV was administered on days 1 and 15. After six consecutive daily sessions of plasma exchange, there was significant regression of the necrotic lesions. After a 22-day hospital stay, the patient was discharged to home on fondaparinux. The patient presented approximately 2 months later after missing follow-up appointments. At the time, his initial lesions looked remarkably improved.

  14. Treating TTP/HUS with plasma exchange: a single centre's 25-year experience.

    Science.gov (United States)

    Forzley, Brian R; Sontrop, Jessica M; Macnab, Jennifer J; Chen, Salina; Clark, William F

    2008-10-01

    Thrombotic thrombocytopenic purpura/Haemolytic uremic syndrome (TTP/HUS) is a thrombotic microangiopathy with a 6-month mortality rate of 16-29%. The present study described the clinical features, treatment regime and 6-month all-cause mortality rate of TTP/HUS patients at the London Health Sciences Centre (LHSC), Canada. Data for this retrospective cohort study were obtained from inpatient and outpatient records for all patients referred for plasma exchange therapy at LHSC, Canada between 1981 and 2006. Patients (n = 110) were categorized as: idiopathic primary (38%) or relapsed (16%), and secondary responsive (30%) or non-responsive (16%). Mortality data were available for all but three patients. The all-cause 6-month mortality rate was 19% overall and was 12% and 26% among idiopathic and secondary TTP/HUS patients, respectively. No mortality events occurred among the 17 idiopathic patients who relapsed. Relapsed patients had the least severe presenting characteristics, the fastest response time, and experienced significant improvement in the severity of clinical features between the first and final presentation. These findings suggest an excellent outcome for relapsed TTP/HUS patients. Patient education, surveillance, and aggressive plasma exchange therapy are hypothesized to improve the likelihood of survival: these hypotheses should be tested in a randomized controlled trial.

  15. Using pharmacokinetic-pharmacodynamic modelling as a tool for prediction of therapeutic effective plasma levels of antipsychotics

    DEFF Research Database (Denmark)

    Olsen, Christina Kurre; Brennum, Lise Tøttrup; Kreilgaard, Mads

    2008-01-01

    response behaviour correlates well with the relationship between human dopamine D2 receptor occupancy and clinical effect. The aim of the present study was to evaluate how pharmacokinetic/pharmacodynamic (PK/PD) predictions of therapeutic effective steady-state plasma levels by means of conditioned...... the rat dopamine D2 receptor occupancy levels providing 50% response in the conditioned avoidance response test and the dopamine D2 receptor occupancy levels reported from responding schizophrenic patients treated with antipsychotics. Predictions of therapeutically effective steady-state levels...... for sertindole (+dehydrosertindole) and olanzapine were 3-4-fold too high whereas for haloperidol, clozapine and risperidone the predicted steady-state EC50 in conditioned avoidance responding rats correlated well with the therapeutically effective plasma levels observed in patients. Accordingly, the proposed PK...

  16. Dextrose-mediated aggregation of therapeutic monoclonal antibodies in human plasma: Implication of isoelectric precipitation of complement proteins.

    Science.gov (United States)

    Luo, Shen; Zhang, Baolin

    2015-01-01

    Many therapeutic monoclonal antibodies (mAbs) are clinically administered through intravenous infusion after mixing with a diluent, e.g., saline, 5% dextrose. Such a clinical setting increases the likelihood of interactions among mAb molecules, diluent, and plasma components, which may adversely affect product safety and efficacy. Avastin® (bevacizumab) and Herceptin® (trastuzumab), but not Remicade® (infliximab), were shown to undergo rapid aggregation upon dilution into 5% dextrose when mixed with human plasma in vitro; however, the biochemical pathways leading to the aggregation were not clearly defined. Here, we show that dextrose-mediated aggregation of Avastin or Herceptin in plasma involves isoelectric precipitation of complement proteins. Using mass spectrometry, we found that dextrose-induced insoluble aggregates were composed of mAb itself and multiple abundant plasma proteins, namely complement proteins C3, C4, factor H, fibronectin, and apolipoprotein. These plasma proteins, which are characterized by an isoelectronic point of 5.5-6.7, lost solubility at the resulting pH in the mixture with formulated Avastin (pH 6.2) and Herceptin (pH 6.0). Notably, switching formulation buffers for Avastin (pH 6.2) and Remicade (pH 7.2) reversed their aggregation profiles. Avastin formed little, if any, insoluble aggregates in dextrose-plasma upon raising the buffer pH to 7.2 or above. Furthermore, dextrose induced pH-dependent precipitation of plasma proteins, with massive insoluble aggregates being detected at pH 6.5-6.8. These data show that isoelectric precipitation of complement proteins is a prerequisite of dextrose-induced aggregation of mAb in human plasma. This finding highlights the importance of assessing the compatibility of a therapeutic mAb with diluent and human plasma during product development.

  17. Combination therapy with mitoxantrone and plasma exchange in aggressive relapsing remitting multiple sclerosis: A preliminary clinical study

    Directory of Open Access Journals (Sweden)

    Nasim Tabrizi

    2012-01-01

    Full Text Available Background: The efficacy of mitoxantrone induction therapy in rapidly worsening multiple sclerosis (MS is well established. Plasma exchange is also applied as an adjuvant in exacerbations of relapsing MS. The aim of this study was to compare the efficacy of combination therapy with mitoxantrone and plasma exchange versus mitoxantrone alone in patients with aggressive MS. Materials and Methods: Forty patients with aggressive relapsing remitting MS were randomly put into two groups. The first group underwent monthly plasma exchange for three successive months, followed by 12 mg/m 2 mitoxantrone at the end of each course and two more doses of 6 mg/m 2 mitoxantrone in 3-month intervals. The second group received the same doses of mitoxantrone only without plasma exchange. At the end of 8 months treatment course, clinical reassessment and neuroimaging was performed and treatment was continued with interferon-β. Results: At the end of induction therapy, Expanded Disability Status Scale score was significantly improved in both groups (P < 0.001. Number of demyelinating and gadolinium-enhancing plaques in brain magnetic resonance imaging (MRI was prominently reduced in group 2 (P ≤ 0.05, but the changes were not statistically significant in group 1, except for juxtacortical plaques. Conclusion: Administration of mitoxantrone as an induction therapy in patients of aggressive relapsing remitting MS results in significant improvement of their clinical state and MRI activity. However, combination of plasma exchange with mitoxantrone gives no more benefits than mitoxantrone alone and sometimes worsens the situation possibly by reduction of mitoxantrone efficacy as a result of plasma exchange.

  18. Study of plasma off-gas treatment from spent ion exchange resin pyrolysis.

    Science.gov (United States)

    Castro, Hernán Ariel; Luca, Vittorio; Bianchi, Hugo Luis

    2017-03-23

    Polystyrene divinylbenzene-based ion exchange resins are employed extensively within nuclear power plants (NPPs) and research reactors for purification and chemical control of the cooling water system. To maintain the highest possible water quality, the resins are regularly replaced as they become contaminated with a range of isotopes derived from compromised fuel elements as well as corrosion and activation products including 14 C, 60 Co, 90 Sr, 129 I, and 137 Cs. Such spent resins constitute a major proportion (in volume terms) of the solid radioactive waste generated by the nuclear industry. Several treatment and conditioning techniques have been developed with a view toward reducing the spent resin volume and generating a stable waste product suitable for long-term storage and disposal. Between them, pyrolysis emerges as an attractive option. Previous work of our group suggests that the pyrolysis treatment of the resins at low temperatures between 300 and 350 °C resulted in a stable waste product with a significant volume reduction (>50%) and characteristics suitable for long-term storage and/or disposal. However, another important issue to take into account is the complexity of the off-gas generated during the process and the different technical alternatives for its conditioning. Ongoing work addresses the characterization of the ion exchange resin treatment's off-gas. Additionally, the application of plasma technology for the treatment of the off-gas current was studied as an alternative to more conventional processes utilizing oil- or gas-fired post-combustion chambers operating at temperatures in excess of 1000 °C. A laboratory-scale flow reactor, using inductively coupled plasma, operating under sub-atmospheric conditions was developed. Fundamental experiments using model compounds have been performed, demonstrating a high destruction and removal ratio (>99.99%) for different reaction media, at low reactor temperatures and moderate power consumption

  19. Development of volume-reduction system for ion exchange resin using inductively coupled plasma

    International Nuclear Information System (INIS)

    Fujisawa, Morio; Katagiri, Genichi

    2002-01-01

    The spent ion exchange resin generated as radioactive waste in water purifying system at nuclear power stations or related facilities of nuclear power has been stored in the site, and its volume has been increasing year by year. We had developed a full-scale system of IC plasma volume-reduction system for the spent resin, and have performed basic performance test using some samples imitating the spent resin. As the results, the imitation of the resin can be reduced in volume by more than 90% so that the processing performance in actual scale was proved to be effective. In addition, it was clarified that the residuum after volume-reduction process is easy to mix with cement, and solidity containing 30wt% residuum provides high strength of 68 MPa. Therefore, we evaluate the application of this process to stabilization of the disposal to be very effective. (author)

  20. Efficacy of liver assisting in patients with hepatic encephalopathy with special focus on plasma exchange

    DEFF Research Database (Denmark)

    Stenbøg, Poul; Busk, Troels; Larsen, Fin Stolze

    2013-01-01

    Severe liver injury result in development of hepatic encephalopathy (HE) and often also in brain edema that is a potentially fatal complication. HE and brain edema are correlated to the level and persistence of hyperammonemia and the presence of systemic inflammation. Treatment of HE and brain...... edema is based on restoring and keeping normal physiological variables including tonicity, blood gasses, lactate, temperature and vascular resistance by a wide variety of interventions. In addition liver support devices improve the stage of HE, cerebral metabolic rate for oxygen and glucose......, and are used either as a bridge to liver transplantation or liver recovery in patients with fulminant hepatic failure and in patients with acute-on-chronic liver failure. This short review will mainly focus on the management and efficacy of doing plasma exchange on HE in patients with acute HE....

  1. Charge exchange as a recombination mechanism in high-temperature plasmas

    International Nuclear Information System (INIS)

    Hulse, R.A.; Post, D.E.; Mikkelsen, D.R.

    1980-03-01

    Charge exchange with neutral hydrogen is examined as a recombination mechanism for multi-charged impurity ions present in high-temperature fusion plasmas. At sufficiently low electron densities, fluxes of atomic hydrogen produced by either the injection of neutral heating beams or the background of thermal neutrals can yield an important or even dominant recombination process for such ions. Equilibrium results are given for selected impurity elements showing the altered ionization balance and radiative cooling rate produced by the presence of various neutral populations. A notable result is that the stripping of impurities to relatively non-radiative ionization states with increasing electron temperature can be postponed or entirely prevented by the application of intense neutral beam heating power. A time dependent calculation modelling the behavior of iron in recent PLT tokamak high power neutral beam heating experiments is also presented

  2. Therapeutic Effect of Platelet-Rich Plasma in Rat Spinal Cord Injuries

    Directory of Open Access Journals (Sweden)

    Nan-Fu Chen

    2018-04-01

    Full Text Available Platelet-rich plasma (PRP is prepared by centrifuging fresh blood in an anticoagulant state, and harvesting the platelet-rich portion or condensing platelets. Studies have consistently demonstrated that PRP concentrates are an abundant source of growth factors, such as platelet-derived growth factor (PDGF, transforming growth factor β (TGF-β, insulin-like growth factor 1 (IGF-1, and epithelial growth factor (EGF. The complex mechanisms underlying spinal cord injury (SCI diminish intrinsic repair and neuronal regeneration. Several studies have suggested that growth factor-promoted axonal regeneration can occur for an extended period after injury. More importantly, the delivery of exogenous growth factors contained in PRP, such as EGF, IGF-1, and TGF-β, has neurotrophic effects on central nervous system (CNS injuries and neurodegenerative diseases. However, only a few studies have investigated the effects of PRP on CNS injuries or neurodegenerative diseases. According to our review of relevant literature, no study has investigated the effect of intrathecal (i.t. PRP injection into the injured spinal cord and activation of intrinsic mechanisms. In the present study, we directly injected i.t. PRP into rat spinal cords and examined the effects of PRP on normal and injured spinal cords. In rats with normal spinal cords, PRP induced microglia and astrocyte activation and PDGF-B and ICAM-1 expression. In rats with SCIs, i.t. PRP enhanced the locomotor recovery and spared white matter, promoted angiogenesis and neuronal regeneration, and modulated blood vessel size. Furthermore, a sustained treatment (a bolus of PRP followed by a 1/3 dose of initial PRP concentration exerted more favorable therapeutic effects than a single dose of PRP. Our findings suggest by i.t. PRP stimulate angiogenesis, enhancing neuronal regeneration after SCI in rats. Although PRP induces minor inflammation in normal and injured spinal cords, it has many advantages. It is an

  3. High-volume plasma exchange in patients with acute liver failure: An open randomised controlled trial.

    Science.gov (United States)

    Larsen, Fin Stolze; Schmidt, Lars Ebbe; Bernsmeier, Christine; Rasmussen, Allan; Isoniemi, Helena; Patel, Vishal C; Triantafyllou, Evangelos; Bernal, William; Auzinger, Georg; Shawcross, Debbie; Eefsen, Martin; Bjerring, Peter Nissen; Clemmesen, Jens Otto; Hockerstedt, Krister; Frederiksen, Hans-Jørgen; Hansen, Bent Adel; Antoniades, Charalambos G; Wendon, Julia

    2016-01-01

    Acute liver failure (ALF) often results in cardiovascular instability, renal failure, brain oedema and death either due to irreversible shock, cerebral herniation or development of multiple organ failure. High-volume plasma exchange (HVP), defined as exchange of 8-12 or 15% of ideal body weight with fresh frozen plasma in case series improves systemic, cerebral and splanchnic parameters. In this prospective, randomised, controlled, multicentre trial we randomly assigned 182 patients with ALF to receive either standard medical therapy (SMT; 90 patients) or SMT plus HVP for three days (92 patients). The baseline characteristics of the groups were similar. The primary endpoint was liver transplantation-free survival during hospital stay. Secondary-endpoints included survival after liver transplantation with or without HVP with intention-to-treat analysis. A proof-of-principle study evaluating the effect of HVP on the immune cell function was also undertaken. For the entire patient population, overall hospital survival was 58.7% for patients treated with HVP vs. 47.8% for the control group (hazard ratio (HR), with stratification for liver transplantation: 0.56; 95% confidence interval (CI), 0.36-0.86; p=0.0083). HVP prior to transplantation did not improve survival compared with patients who received SMT alone (CI 0.37 to 3.98; p=0.75). The incidence of severe adverse events was similar in the two groups. Systemic inflammatory response syndrome (SIRS) and sequential organ failure assessment (SOFA) scores fell in the treated group compared to control group, over the study period (pHVP improves outcome in patients with ALF by increasing liver transplant-free survival. This is attributable to attenuation of innate immune activation and amelioration of multi-organ dysfunction. Copyright © 2015 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.

  4. Cobalt oxide-based catalysts deposited by cold plasma for proton exchange membrane fuel cells

    Energy Technology Data Exchange (ETDEWEB)

    Kazimierski, P.; Jozwiak, L.; Sielski, J.; Tyczkowski, J., E-mail: jacek.tyczkowski@p.lodz.pl

    2015-11-02

    In proton exchange membrane fuel cells (PEMFC), both the anodic hydrogen oxidation reaction and the cathodic oxygen reduction reaction (ORR) require appropriate catalysts. So far, platinum-based catalysts are still the best option for this purpose. However, because these catalysts are too expensive for making commercially viable fuel cells, extensive research over the past decade has focused on developing noble metal-free alternative catalysts. In this paper, an approach based on cobalt oxide films fabricated by plasma-enhanced metal-organic chemical vapor deposition is presented. Such a material can be used to prepare catalysts for ORR in PEMFC. The films containing CoO{sub X} were deposited on a carbon paper thereby forming the electrode. Morphology and atomic composition of the films were investigated by scanning electron microscopy and energy-dispersive X-ray spectroscopy, respectively. The possibility of their application as the electro-catalyst for ORR in PEMFC was investigated and the electro-catalytic activities were evaluated by the electrochemical measurements and single cell tests. It was found that the fuel cell with Pt as the anode catalyst and CoO{sub X} deposit as the cathode catalyst was characterized by the open circuit voltage of 635 mV, Tafel slope of approx. 130 mV/dec and the maximum power density of 5.3 W/m{sup 2}. - Highlights: • Cobalt oxide catalyst for proton exchange membrane fuel cells was plasma deposited. • The catalyst exhibits activity for the oxygen reduction reaction. • Morphology and atomic composition of the catalyst were determined.

  5. Comprehensive Analysis of the Therapeutic IgG4 Antibody Pembrolizumab: Hinge Modification Blocks Half Molecule Exchange In Vitro and In Vivo.

    Science.gov (United States)

    Yang, Xiaoyu; Wang, Fengqiang; Zhang, Ying; Wang, Larry; Antonenko, Svetlana; Zhang, Shuli; Zhang, Yi Wei; Tabrizifard, Mohammad; Ermakov, Grigori; Wiswell, Derek; Beaumont, Maribel; Liu, Liming; Richardson, Daisy; Shameem, Mohammed; Ambrogelly, Alexandre

    2015-12-01

    IgG4 antibodies are evolving as an important class of cancer immunotherapies. However, human IgG4 can undergo Fab arm (half molecule) exchange with other IgG4 molecules in vivo. The hinge modification by a point mutation (S228P) prevents half molecule exchange of IgG4. However, the experimental confirmation is still expected by regulatory agencies. Here, we report for the first time the extensive analysis of half molecule exchange for a hinge-modified therapeutic IgG4 molecule, pembrolizumab (Keytruda) targeting programmed death 1 (PD1) receptor that was approved for advanced melanoma. Studies were performed in buffer or human serum using multiple exchange partners including natalizumab (Tysabri) and human IgG4 pool. Formation of bispecific antibodies was monitored by fluorescence resonance energy transfer, exchange with Fc fragments, mixed mode chromatography, immunoassays, and liquid chromatography-mass spectrometry. The half molecule exchange was also examined in vivo in SCID (severe combined immunodeficiency) mice. Both in vitro and in vivo results indicate that the hinge modification in pembrolizumab prevented half molecule exchange, whereas the unmodified counterpart anti-PD1 wt showed active exchange activity with other IgG4 antibodies or self-exchange activity with its own molecules. Our work, as an example expected for meeting regulatory requirements, contributes to establish without ambiguity that hinge-modified IgG4 antibodies are suitable for biotherapeutic applications. © 2015 Wiley Periodicals, Inc. and the American Pharmacists Association.

  6. Therapeutic efficacy of autologous platelet-rich plasma and polydeoxyribonucleotide on female pattern hair loss.

    Science.gov (United States)

    Lee, Si-Hyung; Zheng, Zhenlong; Kang, Jin-Soo; Kim, Do-Young; Oh, Sang Ho; Cho, Sung Bin

    2015-01-01

    Autologous platelet-rich plasma (PRP) exerts positive therapeutic effects on hair thickness and density in patients with pattern hair loss. The aim of our study was to evaluate the efficacy of intra-perifollicular autologous PRP and polydeoxyribonucleotide (PDRN) injections in treating female pattern hair loss (FPHL). Twenty FPHL patients were treated with a single session of PRP injection, followed by 12 sessions of PDRN intra-perifollicular injection, along the scalp at weekly intervals. Additionally, another 20 FPHL patients were treated with 12 sessions of PDRN injection only. Meanwhile, one half of the backs of two rabbits was injected with the PRP preparation, while the other half was injected with phosphate buffered saline as a control. Tissue samples from the rabbits were analyzed by real-time polymerase chain reaction and Western blotting. Compared with baseline values, patients treated with PRP and PDRN injections exhibited clinical improvement in mean hair counts (23.2 ± 15.5%; p hair thickness (16.8 ± 10.8%; p hair counts (17.9 ± 13.2%; p hair thickness (13.5 ± 10.7%; p hair thickness than treatment with PDRN therapy alone (p = 0.031), but not in hair counts (p > 0.05). The pilot animal study revealed significant up-regulation of WNT, platelet-derived growth factor, and fibroblast growth factor expression in rabbit skin treated with the PRP preparation, compared with control skin. In conclusion, intra-perifollicular injections of autologous PRP and/or PDRN generate improvements in hair thickness and density in FPHL patients. © 2014 by the Wound Healing Society.

  7. 1st IAEA research co-ordination meeting on charge exchange cross section data for fusion plasma studies. Summary report

    International Nuclear Information System (INIS)

    Janev, R.K.

    1999-02-01

    A brief description of the proceedings and the conclusions of the 1st Research Coordination Meeting on 'Charge Exchange Cross Section Data for Fusion Plasma Studies', held on September 24-25, 1999, at the IAEA Headquarters in Vienna, Austria, is provided. The conclusions of the Meeting regarding the data collection, assessment and generation priorities are also included in the report. (author)

  8. Treatment of spent ion-exchange resins in shaft-type reactor with fuel-plasma source of heating

    International Nuclear Information System (INIS)

    Dmitriev, S. A.; Knyazev, I. A.; Lifanov, F. A.; Polkanov, M. A.; Shvetsov, S. Yu; Savkin, A. E.

    1999-01-01

    The method of high-temperature conditioning the spent radioactive ion-exchange resins in combination with other combustible and incombustible radioactive waste in the plasma shaft furnace with obtaining a crystalline glass-like matrix as a final product has been developed. The method was tested on the pilot plant consisted of ceramic plasma melter, steel water-cooled shaft furnace, lined by fire-resistant concrete, and system of gas purification. The capacity of the furnace was within the limits from 10 to 15 kg/h. The volume and mass reduction factors of treated waste were 36 and 7.6, accordingly. The content of gaseous products of thermal decomposition of a waste at an output of the shaft furnace and properties of obtained slag compound were determined. Based on test results the proposals on creation of compact plasma plant for treatment of mixed radioactive waste including spent ion exchange resins were developed. (author). 3 refs., 2 tabs., 2 figs

  9. Elliptically polarized electromagnetic waves in a magnetized quantum electron-positron plasma with effects of exchange-correlation

    Energy Technology Data Exchange (ETDEWEB)

    Shahmansouri, M., E-mail: mshmansouri@gmail.com [Department of Physics, Faculty of Science, Arak University, Arak 38156-8 8349 (Iran, Islamic Republic of); Misra, A. P., E-mail: apmisra@visva-bharati.ac.in, E-mail: apmisra@gmail.com [Department of Mathematics, Siksha Bhavana, Visva-Bharati University, Santiniketan 731 235, West Bengal (India)

    2016-07-15

    The dispersion properties of elliptically polarized electromagnetic waves in a magnetized electron-positron-pair (EP-pair) plasma are studied with the effects of particle dispersion associated with the Bohm potential, the Fermi degenerate pressure, and the exchange-correlation force. Two possible modes of the extraordinary or X wave, modified by these quantum effects, are identified and their propagation characteristics are investigated numerically. It is shown that the upper-hybrid frequency and the cutoff and resonance frequencies are no longer constants but are dispersive due to these quantum effects. It is found that the particle dispersion and the exchange-correlation force can have different dominating roles on each other depending on whether the X waves are of short or long wavelengths (in comparison with the Fermi Debye length). The present investigation should be useful for understanding the collective behaviors of EP plasma oscillations and the propagation of extraordinary waves in magnetized dense EP-pair plasmas.

  10. Exchange and polarization effects in the elementary excitation spectrum of a hydrogen atom immersed in a hot plasma

    International Nuclear Information System (INIS)

    Dharma-wardana, M.W.C.; Grimaldi, F.; Lecourt, A.; Pellissier, J.

    1980-01-01

    The one-particle hydrogenic Green's function has been calculated for a partially ionized plasma consisting of hydrogen atoms, electrons, and protons at high temperatures. The theoretical method extends a previous publication and involves an evaluation of the mass operator in the Dyson equation to include proper self-energy parts to ''all orders'' in the screened interaction. This mass operator characterizes the effective micropotential felt by the atom in the plasma and determines all of the one-particle properties and some two-particle properties associated with the atomic subsystem. The first-order mass operator is nonzero only for exchange scattering, which leads to a frequency-independent exchange shift. This temperature- and density-dependent theory of the exchange shift replaces the usual semiphenomenological schemes based on the Slater-Kohn-Sham type of theory. The exchange-shifted Green's functions are used in evaluating the higher-order contributions. Computer calculations and the resolution of the poles of the Green's function lead to level shifts, widths, and spectral functions. These are calculated within both the second-order and the all-order theory. The second-order theory, which may be valid at sufficiently high densities and in turbulent plasmas, overemphasises the atom-plasmon coupling and shows new structures. The inclusion of contributions beyond second order removes these structures and produces a more ''conventional'' spectral-intensity function. The effects of center-of-mass motion on the level shifts and level profiles are investigated and the onset of plasma instabilities touched upon. These calculations make contact with the work on ''plasma-polarization shifts'' and provide an approach to q,ω-dependent plasma microfields

  11. Transition from the constant ion mobility regime to the ion-atom charge-exchange regime for bounded collisional plasmas

    International Nuclear Information System (INIS)

    Poggie, Jonathan; Sternberg, Natalia

    2005-01-01

    A numerical and analytical study of a planar, collisional, direct-current, plasma-wall problem is presented. The fluid model for the problem is first validated by comparing numerical solutions with experimental data for low-pressure (∼0.1 Pa) electrode sheaths with wall potentials on the order of -100 V. For electric potential, ion number density, and ion velocity, good agreement was found between theory and experiment from within the sheath out to the bulk plasma. The frictional drag resulting from ion-neutral collisions is described by a model incorporating both linear and quadratic velocity terms. In order to study the transition from the constant ion mobility regime (linear friction) to the ion-atom charge-exchange collision regime (quadratic friction), the theoretical model was examined numerically for a range of ion temperatures and ion-neutral collision rates. It was found that the solution profiles in the quasineutral plasma depend on the ion temperature. For low ion temperatures they are governed mainly by the ion-atom charge-exchange regime, whereas for high temperatures they are governed by the constant ion mobility regime. Quasineutral plasma models corresponding to these two limiting cases were solved analytically. In particular, an analytical plasma solution is given for the ion-atom charge exchange regime that includes the effects of ion inertia. In contrast to the quasineutral plasma, the sheath is always governed for low to moderate collision rates by the ion-atom charge-exchange regime, independent of the ion temperature. Varying the collision rate, it was shown that when the wall potential is sufficiently high, the sheath cannot be considered collisionless, even if the collision rate is quite small

  12. Second regional plasmapheresis conference and workshop for Southeast Asia (SEA) on the immunomodulatory role of plasma exchange in central and peripheral nervous system disorders, Kuala Lumpur, Malaysia, 9th December 2017.

    Science.gov (United States)

    Viswanathan, Shanthi; Hung, Stefanie Kar Yan; Goyal, Vinay; Apiwattanakul, Metha; Thirugnanam, Umapathi N; Abdullah, Suhailah; Aye, Seinn Mya Mya; Ohnmar, Ohnmar; Si, Le Tri; Keosodsay, Saysavath; Estiasari, Riwanti; Khalife, Najib; Hiew, Fu Liong

    2018-04-06

    In December 2017, 79 delegates attended the 2nd regional plasmapheresis conference and workshop for Southeast Asia (SEA) on the immunomodulatory role of plasma exchange in central and peripheral nervous system disorders in Kuala Lumpur, Malaysia. This meeting featured 6 plenary lectures, interactive sessions dedicated for experience sharing, case presentations, and a practical session for paramedics. Clinical experts and researchers from 7 SEA countries and India shared experience and challenges in treating autoimmune neurological disorders. While the spectrum of diseases and neurology practice remained largely similar, there was great disparities in accessibility of therapeutic plasma exchange (TPE) within SEA countries and between urban or rural settings. Costs, human resources, and healthcare policies are common challenges in providing sustainable TPE services. Novel techniques and innovative ideas in performing TPE were explored. A working consortium comprising of key opinion leaders was proposed to improve standards of TPE and enhance future research. © 2018 Wiley Periodicals, Inc.

  13. Clinical effect of plasma perfusion combined with plasma exchange in treatment of patients with acute-on-chronic liver failure

    Directory of Open Access Journals (Sweden)

    ZHOU Jian

    2017-04-01

    Full Text Available ObjectiveTo investigate the clinical effect of plasma perfusion (PP combined with plasma exchange (PE in the treatment of acute-on-chronic liver failure (ACLF. MethodsA total of 72 patients with ACLF who were admitted to The Second People’s Hospital of Lanzhou from January 2014 to December 2015 were enrolled. In addition to internal medication, all the patients were treated with the artificial liver support system (once every 3-4 days based on the patients’ conditions, 1-3 times on average for each patient. According to the difference in therapies, the patients were divided into combination group with 40 patients (PP combined with PE and a total of 107 case times and control group with 32 patients (PE alone and a total of 85 case times. Total bilirubin (TBil, alanine aminotransferase (ALT, and prothrombin time were recorded before treatment, after surgery, and at 72 hours after surgery. Clinical outcome was evaluated after 4 weeks of treatment. The t-test was used for comparison of continuous data between groups, and the chi-square test was used for comparison of categorical data between groups. ResultsThe overall response rate of all patients was 63.89% (46/72. At 72 hours after surgery, there was a significant difference in the level of ALT between the combination group and the control group (319.54±86.23 U/L vs 354.75±100.76 U/L, t=2.60, P<0.05. Both groups had significant reductions in TBil and ALT after surgery (combination group: t=6.69 and 15.84, P<0.05; control group: t=5.34 and 14.38, P<0.05 and at 72 hours after surgery (combination group: t=3.24 and 8.83, P<0.05; control group: t=2.40 and 4.61, P<0.05. Both groups had significant changes in prothrombin time activity after surgery (t=4.83 and 5.01, both P<0.05. There were no significant differences in the incidence rates of pruritus and rash between the two groups, while there was a significant difference in the incidence rate of perioral or limb numbness between the

  14. Photon-exchange energy transfer of an electron–hole plasma between quasi-two-dimensional semiconductor layers

    International Nuclear Information System (INIS)

    Lyo, S.K.

    2012-01-01

    Photon-mediated energy transfer is shown to play an important role for transfer of an electron–hole plasma between two quasi-two-dimensional quantum wells separated by a wide barrier. The magnitude and the dependence of the transfer rate of an electron–hole plasma on the temperature, the well-to-well distance, and the plasma density are compared with those of the standard Förster (i.e., dipolar) rate and also with the exciton transfer rate. The plasma transfer rate through the photon-exchange mechanism decays very slowly as a function of the well-to-well distance and is larger than the dipolar rate except for short distances. The transfer rate of plasmas saturates at high densities and decays rapidly with the temperature. - Highlights: ► We study energy transfer (ET) between two two-dimensional semiconductor quantum wells. ► We compare the ET rates of an electron–hole plasma (at a high density) and Mott excitons. ► We show that the proposed photon-exchange rate is practically dominant over the Förster rate. ► We examine the dependences of the ET rate on the temperature, density, and well-to-well distance.

  15. Isotopic exchange processes in cold plasmas of H2/D2 mixtures.

    Science.gov (United States)

    Jiménez-Redondo, Miguel; Carrasco, Esther; Herrero, Víctor J; Tanarro, Isabel

    2011-05-28

    Isotope exchange in low pressure cold plasmas of H(2)/D(2) mixtures has been investigated by means of mass spectrometric measurements of neutrals and ions, and kinetic model calculations. The measurements, which include also electron temperatures and densities, were performed in a stainless steel hollow cathode reactor for three discharge pressures: 1, 2 and 8 Pa, and for mixture compositions ranging from 100% H(2) to 100% D(2). The data are analyzed in the light of the model calculations, which are in good global agreement with the experiments. Isotope selective effects are found both in the surface recombination and in the gas-phase ionic chemistry. The dissociation of the fuel gas molecules is followed by wall recycling, which regenerates H(2) and D(2) and produces HD. Atomic recombination at the wall is found to proceed through an Eley-Rideal mechanism, with a preference for reaction of the adsorbed atoms with gas phase D atoms. The best fit probabilities for Eley-Rideal abstraction with H and D are: γ(ER H) = 1.5 × 10(-3), γ(ER D) = 2.0 × 10(-3). Concerning ions, at 1 Pa the diatomic species H(2)(+), D(2)(+) and HD(+), formed directly by electron impact, prevail in the distributions, and at 8 Pa, the triatomic ions H(3)(+), H(2)D(+), HD(2)(+) and D(3)(+), produced primarily in reactions of diatomic ions with molecules, dominate the plasma composition. In this higher pressure regime, the formation of the mixed ions H(2)D(+) and HD(2)(+) is favoured in comparison with that of H(3)(+) and D(3)(+), as expected on statistical grounds. The model results predict a very small preference, undetectable within the precision of the measurements, for the generation of triatomic ions with a higher degree of deuteration, which is probably a residual influence at room temperature of the marked zero point energy effects (ZPE), relevant for deuterium fractionation in interstellar space. In contrast, ZPE effects are found to be decisive for the observed distribution of

  16. Evaluation of the effect of transcytolemmal water exchange analysis for therapeutic response assessment using DCE-MRI: a comparison study.

    Science.gov (United States)

    Wang, Chunhao; Subashi, Ergys; Liang, Xiao; Yin, Fang-Fang; Chang, Zheng

    2016-07-07

    This study compares the shutter-speed (SS) and the Tofts models as used in assessing therapeutic response in a longitudinal DCE-MRI experiment. Sixteen nu/nu mice with implanted colorectal adenocarcinoma cell line (LS-174T) were randomly assigned into treatment/control groups (n  =  8/group) and received bevacizumab/saline twice weekly (Day1/Day4/Day8). All mice were scanned at one pre- (Day0) and two post-treatment (Day2/Day9) time points using a high spatiotemporal resolution DCE-MRI pulse sequence. The CA extravasation rate constant [Formula: see text] from the Tofts/SS model and the mean intracellular water residence time [Formula: see text] from the SS model were analyzed. A biological subvolume (BV) within the tumor was identified based on the [Formula: see text] intensity distribution, and the SS model parameters within the BV ([Formula: see text] and [Formula: see text]) were analyzed. It is found that [Formula: see text] and [Formula: see text] have a similar spatial distribution in the tumor volume. The Bayesian information criterion results show that the SS model was a better fit for all scans. At Day9, the treatment group had significantly higher tumor mean [Formula: see text] (p  =  0.021), [Formula: see text] (p  =  0.021) and [Formula: see text] (p  = 0.045). When BV from transcytolemmal water exchange analysis was adopted, the treatment group had higher mean [Formula: see text] at both Day2 (p  =  0.038) and Day9 (p  =  0.007). Additionally, at Day9, the treatment group had higher mean [Formula: see text] (p  =  0.045) and higher [Formula: see text] spatial heterogeneity indices (Rényi dimensions) d 1 (p  = 0.010) and d 2 (p  = 0.021). When mean [Formula: see text] and its coefficient of variation (CV) were used to separate treatment/control group samples using supporting vector machine, the accuracy of treatment/control classification was 68.8% at Day2 and 87.5% at Day9; in contrast, the

  17. Elevated plasma glucosylsphingosine in Gaucher disease: relation to phenotype, storage cell markers, and therapeutic response

    NARCIS (Netherlands)

    Dekker, Nick; van Dussen, Laura; Hollak, Carla E. M.; Overkleeft, Herman; Scheij, Saskia; Ghauharali, Karen; van Breemen, Mariëlle J.; Ferraz, Maria J.; Groener, Johanna E. M.; Maas, Mario; Wijburg, Frits A.; Speijer, Dave; Tylki-Szymanska, Anna; Mistry, Pramod K.; Boot, Rolf G.; Aerts, Johannes M.

    2011-01-01

    Gaucher disease, caused by a deficiency of the lysosomal enzyme glucocerebrosidase, leads to prominent glucosylceramide accumulation in lysosomes of tissue macrophages (Gaucher cells). Here we show glucosylsphingosine, the deacylated form of glucosylceramide, to be markedly increased in plasma of

  18. Elevated plasma glucosylsphingosine in Gaucher disease: relation to phenotype, storage cell markers, and therapeutic response

    Science.gov (United States)

    Dekker, Nick; van Dussen, Laura; Hollak, Carla E. M.; Overkleeft, Herman; Scheij, Saskia; Ghauharali, Karen; van Breemen, Mariëlle J.; Ferraz, Maria J.; Groener, Johanna E. M.; Maas, Mario; Wijburg, Frits A.; Speijer, Dave; Tylki-Szymanska, Anna; Mistry, Pramod K.; Boot, Rolf G.

    2011-01-01

    Gaucher disease, caused by a deficiency of the lysosomal enzyme glucocerebrosidase, leads to prominent glucosylceramide accumulation in lysosomes of tissue macrophages (Gaucher cells). Here we show glucosylsphingosine, the deacylated form of glucosylceramide, to be markedly increased in plasma of symptomatic nonneuronopathic (type 1) Gaucher patients (n = 64, median = 230.7nM, range 15.6-1035.2nM; normal (n = 28): median 1.3nM, range 0.8-2.7nM). The method developed for mass spectrometric quantification of plasma glucosylsphingosine is sensitive and robust. Plasma glucosylsphingosine levels correlate with established plasma markers of Gaucher cells, chitotriosidase (ρ = 0.66) and CCL18 (ρ = 0.40). Treatment of Gaucher disease patients by supplementing macrophages with mannose-receptor targeted recombinant glucocerebrosidase results in glucosylsphingosine reduction, similar to protein markers of Gaucher cells. Since macrophages prominently accumulate the lysoglycosphingolipid on glucocerebrosidase inactivation, Gaucher cells seem a major source of the elevated plasma glucosylsphingosine. Our findings show that plasma glucosylsphingosine can qualify as a biomarker for type 1 Gaucher disease, but that further investigations are warranted regarding its relationship with clinical manifestations of Gaucher disease. PMID:21868580

  19. Complete resolution of transplantation-associated thrombotic microangiopathy and hepatic veno-occlusive disease by defibrotide and plasma exchange.

    Science.gov (United States)

    Beşişik, Sevgi Kalayoğlu; Oztürk, Gülistan Bahat; Calişkan, Yaşar; Sargin, Deniz

    2005-03-01

    Transplantation-associated thrombotic microangiopathy has been associated with significantly reduced survival following allogeneic bone marrow transplantation. We describe here the course of Transplantation-associated thrombotic microangiopathy and hepatic veno-occlusive disease, and response to plasma exchange therapy. A 19-year-old male patient underwent hematopoietic stem cell transplantation (HSCT) from his HLA-matched brother for lymphoblastic lymphoma in the first complete remission. Transplantation-associated thrombotic microangiopathy was diagnosed 17 days after transplantation. At that time, neurological abnormalities were not present. Cyclosporin A (CsA) was discontinued. Hematological stabilization was recorded. On day +20, abdominal distention, painful hepatomegaly and ascites complicated the clinical picture. With a high hepatic venous pressure gradient (18mmH20), veno-occlusive disease of the liver was diagnosed and defibrotide was started, which resulted in a dramatic cessation of pain and increase in urinary output. However, transplantation-associated thrombotic microangiopathy-related symptoms progressed and plasma exchange was instituted, which resulted in worsening of veno-occlusive disease symptoms. He was referred to the Intensive Care Unit due to respiratory compromise and was intubated. Plasma exchange was continued in order after hemofiltration. In three days, fever resolved, hemofiltration could be stopped, and ventilator dependence ended. After 19 aphereses, serum LDH level returned to normal and schistocytes were minimal on microscopic examination of the blood film. Platelet count increase was more gradual. Plasma exchange was discontinued. On the 40th day of defibrotide, all symptoms related with veno-occlusive disease were resolved and defibrotide was stopped. We think that our case is important to establish the relation and management strategy of these two small vessel complications of HSCT.

  20. Plasma exchange for paediatric kidney disease-indications and outcomes: a single-centre experience.

    Science.gov (United States)

    Reddy, Sudheer Kumar; Jahan, Afsana; Chaturvedi, Swasti; Agarwal, Indira

    2015-12-01

    Outcome data in paediatrics regarding the use of plasmapheresis for immunological kidney disease are scarce. We aimed to evaluate the role of plasmapheresis in children presenting with severe renal impairment secondary to immunological kidney diseases. A retrospective chart review of children admitted between January 2009 and August 2013 to the Paediatric Nephrology Unit, Christian Medical College, Vellore, India, and requiring plasma exchange was undertaken. Demographic and clinical data were studied and descriptive statistics applied for analysis. Sixteen children underwent plasmapheresis with a male:female ratio of 10:6 and a mean age of 10.2 years (range 5-15 years). Twelve children had atypical haemolytic uraemic syndrome, two had anti-glomerular basement disease and one each had lupus nephritis with neurological manifestation and anti-nuclear cytoplasmic antibody-associated vasculitis. The mean serum creatinine at presentation was 6.52 [interquartile range (IQR) 4.96-7.85] mg/dL with a mean eGFR of 43 (IQR 27.54-56.7) mL/min/1.73 m(2). Other presenting features included nephrotic range proteinuria (69%), gross haematuria (27%), hypertension (94%) and seizures (37.5%). All children received 1.5 times plasma volume plasmapheresis (mean 11 sessions, range 5-26), dialysis and immunosuppressive therapy. The mean duration of follow-up was 4 months (range 2-24 months) with a majority of the children (15/16, 93.75%) surviving acute illness. One child died of overwhelming sepsis and another was lost to follow-up. Of the survivors, eight had eGFR >60 mL/min/1.73 m(2), while eGFR was 15-60 mL/min/1.73 m(2) in the remaining six children. Eight children were still requiring antihypertensive medications and two were continuing peritoneal dialysis at the last follow-up. Thus early introduction of plasmapheresis along with other supportive therapy in immunological kidney disease may improve outcome.

  1. Feasibility of a Miniature Esophageal Heat Exchange Device for Rapid Therapeutic Cooling in Newborns: Preliminary Investigations in a Piglet Model.

    Science.gov (United States)

    Dingley, John; Okano, Satomi; Planas, Silvia; Chakkarapani, Elavazhagan

    2018-03-01

    Therapeutic hypothermia (TH) after neonatal encephalopathy, commonly provided by 72 hours of whole-body cooling using a wrap, limits parents' physical contact with their infants affecting bonding and may not be suitable for encephalopathic preterm infants with fragile skin. Alternative cooling methods are unavailable for this population. We investigated in a neonatal pig model the feasibility of achieving a 3.5°C reduction in rectal temperature (T rectal ) similar to clinical TH protocols from 38.5°C (normothermia for pigs) to a target of 35°C ± 0.2°C, using a novel neonatal esophageal heat exchanger (NEHE), compared its efficacy to passive cooling, and investigated its ability to maintain target T rectal . Ventilated and anesthetized Landrace/Large white newborn pigs had the NEHE inserted. Water at adjustable temperatures and rates flowed down a central tube, returning up a surrounding distensible blind ending latex tube in a continuous loop. An initial experiment guided four subsequent cycles of passive cooling (30 minutes), rewarming to 38.5°C, active esophageal cooling to 35°C ± 0.2°C, active maintenance of target T rectal (30 minutes), and rewarming. We compared surface, rectal temperature, and hemodynamic changes among passive, active, and maintenance phases, and esophageal histopathology against control. Compared with passive cooling, esophageal cooling achieved target T rectal significantly earlier (71.3 minutes vs. 17.25 minutes, p = 0.003) with significantly greater rates of reduction in rectal (p = 0.0002) and surface (p = 0.005) temperatures and heart rate (p = 0.04). A water temperature of 39.1°C-40.2°C at a flow of 108-120 mL/min maintained T rectal around 35°C ± 0.2°C. The higher peak heart rate and blood pressure within 8 minutes of the maintenance phase (p = 0.04) subsequently stabilized. Histopathology showed congestion, edema, and neutrophil infiltration with increasing cycles. Esophageal cooling is

  2. Electron–hole two-stream instability in a quantum semiconductor plasma with exchange-correlation effects

    International Nuclear Information System (INIS)

    Zeba, I.; Yahia, M.E.; Shukla, P.K.; Moslem, W.M.

    2012-01-01

    The electron–hole two-stream instability in a quantum semiconductor plasma has been studied including electrons and holes quantum recoil effects, exchange-correlation potentials, and degenerate pressures of the plasma species. Typical values of GaAs and GaSb semiconductors are used to estimate the growth rate of the two-stream instability. The effects of electron– and hole–phonon collision, quantum recoil effects, the streaming velocities, and the corresponding threshold on the growth rate are investigated numerically. Considering the phonon susceptibility allows the acoustic mode to exist and the collisional instability arises in combination with drift of the holes. -- Highlights: ► Electron–hole two stream instability in quantum plasmas is presented. ► Typical values of GaAs and GaSb semiconductors are used to estimate the growth rate. ► The streaming velocities and the corresponding threshold on the growth rate are investigated numerically.

  3. Factors associated with the effectiveness of plasma exchange for the treatment of NMO-IgG-positive neuromyelitis optica spectrum disorders.

    Science.gov (United States)

    Lim, Young-Min; Pyun, So Young; Kang, Bong-Hui; Kim, Jimin; Kim, Kwang-Kuk

    2013-08-01

    To identify factors associated with plasma exchange response in neuromyelitis optica (NMO) spectrum disorders, the clinical and magnetic resonance imaging (MRI) features of 31 NMO-IgG-positive patients receiving plasma exchange for steroid-resistant exacerbations were analyzed. Functional improvement was observed in 65% of the patients. A lower baseline Expanded Disability Status Scale score was associated with favorable response (p = 0.040). Patients without cord atrophy had a higher success rate than patients with atrophy (p = 0.016). Levels of NMO-IgG did not differ between responders and non-responders before and after plasma exchange. In conclusion, a minimal pre-existing disability is the primary determinant of the effectiveness of plasma exchange.

  4. The effects of therapeutic concentrations ofamisulpride andrisperidone on human plasma lipid peroxidation – invitro studies

    Directory of Open Access Journals (Sweden)

    Anna Dietrich-Muszalska

    2011-09-01

    Full Text Available Introduction: Antipsychotics may in different ways affect the oxidative stress measured by plasma lipid peroxidation. Probably some of them may intensify the oxidative balance disturbances occurring in schizophrenia. The effects of amisulpride and risperidone on redox processes are not known sufficiently yet. Aim of the study: Establishment of the effects of amisulpride and risperidone on human plasma lipid peroxidation measured by determination of the level of thiobarbituric acid-reactive substances (TBARS, in vitro. Material and methods: Blood for the studies was collected from healthy volunteers (aged 24-26 years for ACD solution. Active substances of the examined drugs were dissolved in 0.01% dimethylsulfoxide (DMSO to the final concentrations (of amisulpride 578 ng/ml and risperidone 64 ng/ml and incubated with plasma for 1 and 24 hours at 37ºC. For each experiment the control samples of plasma with DMSO (without the drug were performed. The lipid peroxidation level was measured in plasma by determining the TBARS concentration, using the spectrophotometric method (acc. to Rice-Evans, 1991. The results were analysed using the following statistical methods: the paired Student t-test and ANOVA II variance analysis and NIR test (StatSoft Inc., Statistica v. 6.0. Results: The ANOVA II variance analysis indicated significant differences in the effects of both drugs on TBARS level (F=4.26; df=2, p0.05. Conclusion: Amisulpride and risperidone in concentrations corresponding to doses recommended for treatment of acute episode of schizophrenia do not induce oxidative stress measured by lipid peroxidation. Unlike risperidone, amisulpride exhibits antioxidative effects.

  5. On methods of measuring the relative plasma composition by active charge exchange

    International Nuclear Information System (INIS)

    Herrmann, W.

    1991-04-01

    Two methods of measuring the hydrogenic composition of plasma with an active diagnostic beam are discussed: Evaluation at equal energies of the neutrals leaving the plasma and at equal velocities. Evaluation at equal velocity has the advantage that the plasma composition, particle penetration and stripping efficiency of the analyzer do not enter the evaluation. The only plasma parameter that has to be known is the plasma temperature. If measurement at two different velocities is possible, the temperature can also be evaluated from the corresponding four fluxes without any further knowledge of plasma or beam parameters. It is discussed under what circumstances evaluation of the plasma composition is possible for non-Maxwellian distribution functions. As the halo effect may be the main source of error, it is shown that the application of a helium beam may considerably reduce this problem. (orig.)

  6. The effect of insulin deficiency on the plasma clearance and exchange of high-density-lipoprotein phosphatidylcholine in rats.

    Science.gov (United States)

    Martins, I J; Redgrave, T G

    1992-01-01

    Triolein/cholesteryl oleate/cholesterol/phosphatidylcholine emulsions designed to model the lipid composition of chylomicrons were injected intravenously into control and streptozotocin-treated insulin-deficient rats. As previously described for lymph chylomicrons, the emulsion triolein was hydrolysed and phosphatidylcholine was transferred to the plasma high-density lipoproteins (HDL). This mechanism was used to introduce a phospholipid label into HDL in vivo. The subsequent clearance of phospholipid radioactivity from the plasma of insulin-deficient rats was significantly slower than in controls (P less than 0.025). Plasma clearance was similarly slower in insulin-deficient rats after injection of HDL that was previously labelled with radioactive phospholipids. After injection, the phospholipid label redistributed rapidly between the large-particle fraction of plasma lipoproteins (very-low- and low-density lipoproteins), and the lighter and heavier fractions of HDL. Compared with control rats, in insulin-deficient rats less of the phospholipid label was distributed to the lighter HDL fraction and more to the heavier HDL fraction, and this difference was not due to changes in activity of lecithin: cholesterol acyltransferase or in the apparent activity of phospholipid transfer protein. In insulin-deficient rats the changes in HDL phospholipid clearance and exchange appeared to be secondary to the associated hypertriglyceridaemia and the related changes in distribution of phospholipids between classes of plasma lipoproteins. PMID:1536661

  7. Review of Langmuir-wave-caused dips and charge-exchange-caused dips in spectral lines from plasmas and their applications

    Czech Academy of Sciences Publication Activity Database

    Dalimier, E.; Oks, E.; Renner, Oldřich

    2014-01-01

    Roč. 2, č. 2 (2014), s. 178-194 ISSN 2218-2004 Grant - others:AVČR(CZ) M100101208 Institutional support: RVO:68378271 Keywords : Laser-matter interaction * spectral line profiles * Langmuir waves * plasma electron density * charge exchange rates Subject RIV: BL - Plasma and Gas Discharge Physics

  8. Novel Therapeutic Effects of Non-thermal atmospheric pressure plasma for Muscle Regeneration and Differentiation

    Science.gov (United States)

    Choi, Jae Won; Kang, Sung Un; Kim, Yang Eun; Park, Ju Kyeong; Yang, Sang Sik; Kim, Yeon Soo; Lee, Yun Sang; Lee, Yuijina; Kim, Chul-Ho

    2016-01-01

    Skeletal muscle can repair muscle tissue damage, but significant loss of muscle tissue or its long-lasting chronic degeneration makes injured skeletal muscle tissue difficult to restore. It has been demonstrated that non-thermal atmospheric pressure plasma (NTP) can be used in many biological areas including regenerative medicine. Therefore, we determined whether NTP, as a non-contact biological external stimulator that generates biological catalyzers, can induce regeneration of injured muscle without biomaterials. Treatment with NTP in the defected muscle of a Sprague Dawley (SD) rat increased the number of proliferating muscle cells 7 days after plasma treatment (dapt) and rapidly induced formation of muscle tissue and muscle cell differentiation at 14 dapt. In addition, in vitro experiments also showed that NTP could induce muscle cell proliferation and differentiation of human muscle cells. Taken together, our results demonstrated that NTP promotes restoration of muscle defects through control of cell proliferation and differentiation without biological or structural supporters, suggesting that NTP has the potential for use in muscle tissue engineering and regenerative therapies. PMID:27349181

  9. Case reports of the use of immunoadsorption or plasma exchange in high-risk pregnancies of women with antiphospholipid syndrome.

    Science.gov (United States)

    Bortolati, Maria; Marson, Piero; Chiarelli, Silvia; Tison, Tiziana; Facchinetti, Myriam; Gervasi, Maria Teresa; De Silvestro, Giustina; Ruffatti, Amelia

    2009-04-01

    Conventional treatment of antiphospholipid syndrome (APS) pregnancies with aspirin and/or heparin is sometimes unable to counteract maternal and/or fetal complications. In this article we report the cases of two patients who were unresponsive to conventional treatment for APS during their first pregnancy, and who were treated in the following pregnancy with plasma exchange and immunoadsorption respectively, in addition to conventional therapy. Both patients had a history of thrombotic events, a previous pregnancy loss at the 11th week of gestation and the same antiphospholipid antibody profile (lupus anticoagulant activity and high titers of immunoglobulin G (IgG) anti-beta2 glycoprotein I and IgG anticardiolipin antibodies). Patient 1 was treated from the fourth week of her second pregnancy with weekly plasma exchange. Due to fetal growth restriction and oligohydramnios in the 26th week she delivered, by cesarean section, a healthy female infant weighing 730 g who survived. Patient 2 was treated from the seventh week of her second pregnancy with twice a week protein A immunoadsorption. The pregnancy proceeded normally until the 36th week, when, due to slight intrauterine growth restriction, she delivered a healthy baby girl weighing 2375 g by cesarean section. Anti-beta2 glycoprotein I antibody trends were similar during both types of treatment. On the basis of our findings obtained from only two cases it is impossible to define the best aphaeretic treatment of APS high risk pregnancies. Nevertheless, as a whole these data suggest better disease control using the immunoadsorption technique as compared to plasma exchange, despite their apparently similar anti-beta2 glycoprotein I antibody removal capabilities.

  10. Identification of the sodium-calcium exchanger as the major ricin-binding glycoprotein of bovine rod outer segments and its localization to the plasma membrane

    International Nuclear Information System (INIS)

    Reid, D.M.; Molday, R.S.; Friedel, U.; Cook, N.J.

    1990-01-01

    After neuraminidase treatment the Na + /Ca 2+ exchanger of bovine rod outer segments was found to specifically bind Ricinus communis agglutinin. SDS gel electrophoresis and Western blotting of ricin-binding proteins purified from rod outer segment membranes by lectin affinity chromatography revealed the existence of two major polypeptides of M r 215K and 103K, the former of which was found to specifically react with PMe 1B3, a monoclonal antibody specific for the 230-kDa non-neuraminidase-treated Na + /Ca 2+ exchanger. Reconstitution of the ricin affinity-purified exchanger into calcium-containing liposomes revealed that neuraminidase treatment had no significant effect on the kinetics of Na + /Ca 2+ exchange activation by sodium. The authors further investigated the density of the Na + /Ca 2+ exchanger in disk and plasma membrane preparations using Western blotting, radioimmunoassays, immunoelectron microscopy, and reconstitution procedures. The results indicate that the Na + /Ca 2+ exchanger is localized in the rod photoreceptor plasma membrane and is absent or present in extremely low concentrations in disk membranes, as they have previously shown to be the case for the cGMP-gated cation channel. Previous reports describing the existence of Na + /Ca 2+ exchange activity in rod outer segment disk membrane preparations may be due to the fusion of plasma membrane components and/or the presence of contaminating plasma membrane vesicles

  11. Regulation of mitogen-activated protein kinase pathways by the plasma membrane Na+/H+ exchanger, NHE1

    DEFF Research Database (Denmark)

    Pedersen, Stine Helene Falsig; Darborg, Barbara Vasek; Rentsch, Maria Louise

    2006-01-01

    activity is regulated by a three-tiered phosphorelay system, which is in turn regulated by a complex network of signaling events and scaffolding proteins. The ubiquitous plasma membrane Na(+)/H(+) exchanger NHE1 is activated by, and implicated in, the physiological/pathophysiological responses to many...... of the same stimuli that modulate MAPK activity. While under some conditions, NHE1 is regulated by MAPKs, a number of studies have, conversely, implicated NHE1 in the regulation of MAPK activity. Here, we discuss the current evidence indicating the involvement of NHE1 in MAPK regulation, the mechanisms...

  12. Plasma Deposited Thin Iron Oxide Films as Electrocatalyst for Oxygen Reduction Reaction in Proton Exchange Membrane Fuel Cells

    Directory of Open Access Journals (Sweden)

    Lukasz JOZWIAK

    2017-02-01

    Full Text Available The possibility of using plasma deposited thin films of iron oxides as electrocatalyst for oxygen reduction reaction (ORR in proton exchange membrane fuel cells (PEMFC was examined. Results of energy-dispersive X-ray spectroscopy (EDX and X-ray photoelectron spectroscopy (XPS analysis indicated that the plasma deposit consisted mainly of FeOX structures with the X parameter close to 1.5. For as deposited material iron atoms are almost exclusively in the Fe3+ oxidation state without annealing in oxygen containing atmosphere. However, the annealing procedure can be used to remove the remains of carbon deposit from surface. The single cell test (SCT was performed to determine the suitability of the produced material for ORR. Preliminary results showed that power density of 0.23 mW/cm2 could be reached in the tested cell.DOI: http://dx.doi.org/10.5755/j01.ms.23.1.14406

  13. Tendinopathies and platelet-rich plasma (PRP: from pre-clinical experiments to therapeutic use

    Directory of Open Access Journals (Sweden)

    Kaux JF

    2015-05-01

    Full Text Available Objectives: The restorative properties of platelets, through the local release of growth factors, are used in various medical areas. This article reviews fundamental and clinical research relating to platelet-rich plasma applied to tendinous lesions. Materials and method: Articles in French and English, published between 1 January 2012 and 31 December 2014. dealing with PRP and tendons were searched for using the Medline and Scopus data bases. Results: Forty-seven articles were identified which addressed pre-clinical and clinical studies: 27 relating to in vitro and in vivo animal studies and 20 relating to human studies. Of these, five addressed lateral epicondylitis, two addressed rotator cuff tendinopathies, ten dealt with patellar tendinopathies and three looked at Achilles tendinopathies. Conclusions: The majority of pre-clinical studies show that PRP stimulates the tendon's healing process. However, clinical series remain more controversial and level 1, controlled, randomised studies are still needed.

  14. Raised Plasma Neurofilament Light Protein Levels Are Associated with Abnormal MRI Outcomes in Newborns Undergoing Therapeutic Hypothermia

    Directory of Open Access Journals (Sweden)

    Divyen K. Shah

    2018-03-01

    Full Text Available Aims and hypothesisHypoxic-ischemic encephalopathy (HIE remains an important cause of death and disability in newborns. Mild therapeutic hypothermia (TH is safe and effective; however, there are no tissue biomarkers available at the bedside to select babies for treatment. The aim of this study was to show that it is feasible to study plasma neurofilament light (NfL levels from newborns and to evaluate their temporal course. Hypothesis: Raised plasma NFL protein levels from newborns who undergo TH after HIE are associated with abnormal MRI outcomes.MethodsBetween February 2014 and January 2016, term newborns with HIE treated with TH for 72 h had plasma samples taken at three time points: (i after the infant had reached target temperature, (ii prior to commencing rewarming, and (iii after completing rewarming. Infants with mild HIE who did not receive TH had a single specimen taken. NfL protein was analyzed using an enzyme-linked immunosorbent assay.ResultsTwenty-six newborns with moderate–severe HIE treated with TH were studied. Half of these had cerebral MRI predictive of an unfavorable outcome. Plasma NfL levels were significantly higher in the TH group with unfavorable outcome (median age 18 h compared to levels from both the mild HIE group and TH group with favorable outcome (F = 25.83, p < 0.0001. Newborns who had MRIs predictive of unfavorable outcome had significantly higher NfL levels compared to those with favorable outcomes, at all three time points (mixed models, F = 27.63, p < 0.001. A cutoff NfL level >29 pg/mL at 24 h is predictive of an unfavorable outcome [sensitivity 77%, specificity 69%, positive predictive value (PPV 67%, negative predictive value (NPV 72%] with increasing predictive value until after rewarming (sensitivity 92%, specificity 92%, PPV 92%, NPV 86%.Interpretation of researchPlasma NfL protein levels may be a useful biomarker of unfavorable MRI outcomes in newborns with moderate

  15. Serial plasma choline measurements after cardiac arrest in patients undergoing mild therapeutic hypothermia: a prospective observational pilot trial.

    Directory of Open Access Journals (Sweden)

    Christian Storm

    Full Text Available OBJECTIVE: Choline is related to phospholipid metabolism and is a marker for global ischaemia with a small reference range in healthy volunteers. The aim of our study was to characterize the early kinetics of plasma free choline in patients after cardiac arrest. Additionally, we investigated the potential of plasma free choline to predict neurological outcome. METHODS: Twenty patients admitted to our medical intensive care unit were included in this prospective, observational trial. All patients were enrolled between May 2010 and May 2011. They received post cardiac arrest treatment including mild therapeutic hypothermia which was initiated with a combination of cold fluid and a feedback surface cooling device according to current guidelines. Sixteen blood samples per patient were analysed for plasma free choline levels within the first week after resuscitation. Choline was detected by liquid chromatography-tandem mass spectrometry. RESULTS: Most patients showed elevated choline levels on admission (median 14.8 µmol/L; interquartile range; IQR 9.9-20.1 which subsequently decreased. 48 hours after cardiac arrest choline levels in all patients reached subnormal levels at a median of 4.0 µmol/L (IQR 3-4.9; p = 0.001. Subsequently, choline levels normalized within seven days. There was no significant difference in choline levels when groups were analyzed in relation to neurological outcome. CONCLUSIONS: Our data indicate a choline deficiency in the early postresucitation phase. This could potentially result in impaired cell membrane recovery. The detailed characterization of the early choline time course may aid in planning of choline supplementation trials. In a limited number of patients, choline was not promising as a biomarker for outcome prediction.

  16. Population pharmacokinetics of piperacillin in the early phase of septic shock: does standard dosing result in therapeutic plasma concentrations?

    Science.gov (United States)

    Öbrink-Hansen, Kristina; Juul, Rasmus Vestergaard; Storgaard, Merete; Thomsen, Marianne Kragh; Hardlei, Tore Forsingdal; Brock, Birgitte; Kreilgaard, Mads; Gjedsted, Jakob

    2015-11-01

    Antibiotic dosing in septic shock patients poses a challenge for clinicians due to the pharmacokinetic (PK) variability seen in this patient population. Piperacillin-tazobactam is often used for empirical treatment, and initial appropriate dosing is crucial for reducing mortality. Accordingly, we determined the pharmacokinetic profile of piperacillin (4 g) every 8 h, during the third consecutive dosing interval, in 15 patients treated empirically for septic shock. We developed a population pharmacokinetic model to assess empirical dosing and to simulate alternative dosing regimens and modes of administration. Time above the MIC (T>MIC) predicted for each patient was evaluated against clinical breakpoint MIC for Pseudomonas aeruginosa (16 mg/liter). Pharmacokinetic-pharmacodynamic (PK/PD) targets evaluated were 50% fT>4×MIC and 100% fT>MIC. A population PK model was developed using NONMEM, and data were best described by a two-compartment model. Central and intercompartmental clearances were 3.6 liters/h (relative standard error [RSE], 15.7%) and 6.58 liters/h (RSE, 16.4%), respectively, and central and peripheral volumes were 7.3 liters (RSE, 11.8%) and 3.9 liters (RSE, 9.7%), respectively. Piperacillin plasma concentrations varied considerably between patients and were associated with levels of plasma creatinine. Patients with impaired renal function were more likely to achieve predefined PK/PD targets than were patients with preserved or augmented renal function. Simulations of alternative dosing regimens showed that frequent intermittent bolus dosing as well as dosing by extended and continuous infusion increases the probability of attaining therapeutic plasma concentrations. For septic shock patients with preserved or augmented renal function, dose increment or prolonged infusion of the drug needs to be considered. (This study has been registered at ClinicalTrials.gov under registration no. NCT02306928.). Copyright © 2015, American Society for Microbiology

  17. Loading regimen required to rapidly achieve therapeutic trough plasma concentration of teicoplanin and evaluation of clinical features

    Directory of Open Access Journals (Sweden)

    Seki M

    2012-11-01

    Full Text Available Masafumi Seki,1,* Kaori Yabuno,1,2,* Koji Miyawaki,1,2 Yoshihiro Miwa,2 Kazunori Tomono11Division of Infection Control and Prevention, 2Department of Pharmacy, Osaka University Hospital, Suita, Osaka, Japan*These authors contributed equally to this workBackground: A trough concentration of >20 mg/L is considered the optimal dosage of teicoplanin required to ensure early therapeutic effects against methicillin-resistant Staphylococcus aureus (MRSA infections including those in patients who develop febrile neutropenia after chemotherapy. This study determines appropriate initial doses during the first 2 days of administration and evaluates the therapeutic target teicoplanin trough concentration.Method: A 2-day regimen was evaluated in patients treated with 600 mg and 1200 mg or 1200 mg and 600 mg (total 1800 mg, Group 1, 800 mg and 800 mg (total 1600 mg, Group 2, and 800 mg and 400 mg (total 1200 mg, Group 3 of teicoplanin on Days 1 and 2, respectively. We also compared the efficiency and adverse effects at trough concentrations of 15–20 mg/L (Group A, n = 28 with >20 mg/L (Group B, n = 27 of teicoplanin, and also compared them with those on the similar concentrations of vancomycin (Groups C and D, n = 50 and 34, respectively.Results: The mean trough concentrations of teicoplanin on Days 4 or 5 were 22.2, 17.5, and 16.2 mg/L in Groups 1, 2, and 3, respectively. The clinical efficiency was 85.7%, 81.5%, 92.0%, and 91.5%, in Groups A, B, C, and D, respectively. The rates of adverse effects were not high in teicoplanin (nephrotoxicity, 7.1% and 3.7%, and hepatotoxicity, 14.3% and 11.1% in Groups A and B, respectively. However, more adverse effects tended to arise in patients who received vancomycin in nephrotoxicity (14.0% and 11.8%, in Groups C and D, respectively.Conclusion: These results suggest that the 2-day regimens with total 1800 mg achieved the most effective therapeutic trough plasma concentration of teicoplanin (20 mg/L. However, 15–20

  18. Citrate Anticoagulation in Tandem Membrane Plasma-Exchange or Immunoadsorption and Hemodialysis in Patients With Immunological Diseases and Dialysis-Dependence.

    Science.gov (United States)

    Ponikvar, Rafael; Gubenšek, Jakob; Ponikvar, Jadranka Buturović

    2016-06-01

    In 1996 we performed tandem membrane plasma exchange-hemodialysis in a 3-year-old girl and tandem immunoadsorption-hemodialysis with citrate as the only anticoagulant in a patient with Goodpasture's syndrome. In the present study, we evaluated the feasibility, efficacy and safety of 24 tandem plasma exchange/immunoadsorption hemodialysis procedures in four different circuit setups with citrate as the only anticoagulant. In two setups, the tandem procedures were connected in series (plasma exchange hemodialysis and immunoadsorption hemodialysis), while in the other two setups they were in parallel (plasma exchange hemodialysis with independent blood circuits and plasma exchange hemodialysis with independent arterial blood lines, but with a common return line). All tandem procedures were feasible, efficient and safe. No serious side-effects were recorded. The most elegant setup was the procedure with independent, parallel blood circuits. However, serial tandem procedures provided for the elimination of citrate and normalization of electrolytes before blood was returned to the patient. © 2016 International Society for Apheresis, Japanese Society for Apheresis, and Japanese Society for Dialysis Therapy.

  19. Charge exchange induced X-ray transitions of hollow ions in laser field ionized plasmas

    International Nuclear Information System (INIS)

    Rosmej, F.B.; Hoffmann, D.H.H.; Faenov, A. Ya.; Pikuz, T.A.; Magunov, A.I.; Skobelev, I.Yu.; Auguste, T.; D'Oliveira, P.; Hulin, S.; Monot, P.

    2000-01-01

    Double electron charge exchange is proposed for the formation of hollow He-like ions when laser field ionized nuclei penetrate into the residual gas. Using transitions from different configurations in hollow ions a method for the determination of the electron temperature in the long lasting recombination phase is developed

  20. Heat exchange between a microparticle and plasma. Contribution of charge transfer processes

    International Nuclear Information System (INIS)

    Uglov, A.A.; Gnedovets, A.G.

    1983-01-01

    Heat- and mass-transfer in interaction of a microparticle with a dense plasma have been considered analytically. At that, calculation methods developed as applied to probe diagnostics of slightly ionized plasma are also used in the case of relatively high degrees of ionization, at which heat flows of plasma charged particles Qe and Qi become comparable with molecular ones. High efficiency of energy transfer during electron and ion collisions with a microparticle is due to the following: 1) effective cross section of ion collision with a microparticle, which acquires in a quasineutral plasma the potential phisub(f) < 0, surpasses the geometric one; the maximum contribution of electron and ion constituent is achieved when the cross section ion collisions with a microparticle is linearly connected with its potential, 2) with a charged microparticle electrons from distribution function ''tail'' collide, their energy exceeds potential barrier near the surface and, consequently, the mean heat energy; 3) besides the energy of a microparticle thermal movement during electron recombination and ion neutralization on its surface the heat Qsub(e) and Qsub(i), which considerably exceed the heat of molecular adsorption and mean heat energy of plasma particles at kT approximately 1 eV, are transmitted to the microparticle

  1. Effect of plasma exchange on in-hospital mortality in patients with pulmonary hemorrhage secondary to antineutrophil cytoplasmic antibody-associated vasculitis: A propensity-matched analysis using a nationwide administrative database.

    Science.gov (United States)

    Uechi, Eishi; Okada, Masato; Fushimi, Kiyohide

    2018-01-01

    Secondary pulmonary hemorrhage increases the risk of mortality in patients with antineutrophil cytoplasmic antibody-associated vasculitis (AAV); plasma exchange therapy may improve outcomes in these patients. We conducted a retrospective cohort study to investigate the effect of plasma exchange therapy on short-term prognoses in patients with pulmonary hemorrhage secondary to AAV. This study utilized the Diagnosis Procedure Combination database, which is a nationwide inpatient database in Japan. We checked the abstract data and medical actions and identified the patients with pulmonary hemorrhage secondary to AAV who required proactive treatment between 2009 and 2014. To compare the in-hospital mortality, we performed propensity score matching between the plasma exchange and non-plasma exchange groups at a ratio of 1:1. Of the 52,932 patients with AAV, 940 developed pulmonary hemorrhage as a complication. A total of 249 patients from 194 hospitals were eligible for the study. Propensity score matching at a ratio of 1:1 was performed, and 59 pairs were formed (plasma exchange group, n = 59; non-plasma exchange group, n = 59). A statistically significant difference was found in the all-cause in-hospital mortality between the plasma exchange and non-plasma exchange groups (35.6% vs. 54.2%; p = 0041; risk difference, -18.6; 95% confidence interval (CI), -35.4% to -0.67%). Thus, plasma exchange therapy was associated with improved in-hospital mortality in patients with pulmonary hemorrhage secondary to AAV.

  2. Charge-exchange recombination spectroscopy measurements of ion temperature and plasma rotation in PBX

    International Nuclear Information System (INIS)

    Jaehnig, K.P.; Fonck, R.J.; Ida, K.; Powell, E.T.

    1984-11-01

    The primary diagnostic on PBX for ion temperature measurements is charge-exchange recombination spectroscopy of low Z ions, wherein fast neutrals from the heating neutral beams excite spectral lines from highly excited states (n greater than or equal to 4) of hydrogenic 0, C, and He via charge-exchange collisions with the respective fully stripped ions. Since the neutral beams on PBX provide relatively low velocity neutrals (i.e., D 0 beams at 44 keV), the best signals are obtained using the near-uv lines of 0 7+ (e.g., n = 8-7, 2976 A). Off-line analysis of the Doppler broadened and shifted line profiles includes non-linear least squares fitting to a model line profile, while a simplified on-line fast analysis code permits between-shot data analysis

  3. Flow-Induced New Channels of Energy Exchange in Multi-Scale Plasma Dynamics - Revisiting Perturbative Hybrid Kinetic-MHD Theory.

    Science.gov (United States)

    Shiraishi, Junya; Miyato, Naoaki; Matsunaga, Go

    2016-05-10

    It is found that new channels of energy exchange between macro- and microscopic dynamics exist in plasmas. They are induced by macroscopic plasma flow. This finding is based on the kinetic-magnetohydrodynamic (MHD) theory, which analyses interaction between macroscopic (MHD-scale) motion and microscopic (particle-scale) dynamics. The kinetic-MHD theory is extended to include effects of macroscopic plasma flow self-consistently. The extension is realised by generalising an energy exchange term due to wave-particle resonance, denoted by δ WK. The first extension is generalisation of the particle's Lagrangian, and the second one stems from modification to the particle distribution function due to flow. These extensions lead to a generalised expression of δ WK, which affects the MHD stability of plasmas.

  4. Plasma FITC-dextran exchange between the primary and secondary circulatory systems in the Atlantic cod, Gadus Morhua

    DEFF Research Database (Denmark)

    Fischer, Claes; Steffensen, John Fleng

    2008-01-01

    Fluorescein isothiocyanate dextran (FITC-dextran) exchange between the primary (PCS) and secondary (SCS) circulatory systems in the Atlantic cod, Gadus morhua (Linnaeus, 1752), were studied using 20-kDa (n = 4) and 500-kDa (n = 4) FITC-dextran. In order to give a qualitative perspective...... of the general connection between the PCS and SCS, distribution of plasma-borne tracers (FITC-dextran) in the PCS and SCS were examined. In this study, a total of eight cod were cannulated in the ventral aorta (PCS) and dorsal cutaneous vessel (SCS), for investigation of FITC-dextran disappearance in the PCS...... and its subsequent appearance in the SCS. FITC-dextran of both sizes was found to be in equilibrium between the PCS and SCS in less than 20 min. This indicates a profound connection between the PCS and SCS in the Atlantic cod, and rapid mixing of tracers between the PCS and SCS. The destination...

  5. Impurity line emission due to thermal charge exchange in JET edge plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Maggi, C F; Horton, L D; Koenig, R; Stamp, M [Commission of the European Communities, Abingdon (United Kingdom). JET Joint Undertaking; Summers, H P [Strathclyde Univ., Glasgow (United Kingdom)

    1994-07-01

    High n-shell emission from hydrogen-like carbon (C VI, n=8-7) has been routinely observed from the plasma edge of JET. By comparing the measured spectral line intensities with the signals predicted by advanced atomic physics modelling of carbon and hydrogen radiation, integrated with modelling of the divertor and edge plasma, it is concluded that charge transfer from excited state hydrogen donors into fully stripped carbon ions can account for the observed spectral emission, but that the hydrogen distribution and to a lesser extent the carbon distribution away from the strike zone predicted by the transport model are too low. Data presented are those of three upper X-point discharges, where the target material was carbon. 5 refs., 1 fig., 3 tabs.

  6. Effect of intensive plasma exchange (PE) in rapidly progressive crescentic glomerulonephritis (RPCGN).

    Science.gov (United States)

    D'Amico, G; Sinico, R; Fornasieri, A; Ferrario, F; Colasanti, G; Porri, M T; Paracchini, M L; Gibelli, A

    1983-07-01

    Ten adult patients with RPCGN (crescents in greater than 70% of glomeruli), primary in 6 and associated with systemic diseases in 4, were treated with PE, associated with oral steroids (P) and cyclophosphamide (C) in all cases and with intravenous methylprednisolone pulses (MP) in 7 cases. Four out of ten patients were anuric and needed dialysis treatment at the start of treatment. Therapeutic benefit, i.e. reversal of the trend to further deterioration and substantial improvement of GFR, was achieved in 8 out of 10 patients (80%), including 2 of 4 anuric patients, and in 7 of those (8) who had still active cellular crescents (87.5%). Similar therapeutic benefit had been achieved only in 10% of a comparable population of 10 patients with RPCGN treated before 1980 with P and C, without PE or MP pulses. It is difficult to establish whether the better therapeutic results in the more recently treated group were due to PE or to MP pulses of to both the new approaches, even though the clinical improvement obtained in all the 3 patients treated with PE without concomitant MP suggest a specific beneficial role for PE. RPCGN is a catastrophic illness characterized by progressive deterioration of kidney function, resulting in oliguria and uremia, usually within weeks or months. The most consistent histopathologic finding is the presence of extensive glomerular crescents resulting from proliferation of the extracapillary epithelial cell lining of Bowman's capsule. It is apparent that RPCGN is not a homogeneous entity, clinically, histologically or immunohistologically, but rather a clinicopathologic syndrome, the features of which may be seen in a variety of systemic disorders, including SLE, polyarteritis nodosa, Wegener's granulomatosis, Henoch-Schönlein purpura, cryoglobulinemia, and subacute bacterial endocarditis.(ABSTRACT TRUNCATED AT 250 WORDS)

  7. Time-of-flight analysis of charge-exchange neutral particles from the TORTUR II plasma

    International Nuclear Information System (INIS)

    Brocken, H.J.B.M.

    1981-10-01

    A disc chopper for time-of-flight analysis of fast neutral particles was constructed for the determination of the ion energy spectrum at lower energies than can be obtained by conventional electro-magnetic analyzers. The method has been applied to the TORTUR II tokamak. The chopper and detection system are described and the measurements are presented. For the interpretation of the results of the measurements a data analysis procedure was developed. The influence of reflections of neutrals at the liner wall showed to be important in the calculations of the neutral density profile at the plasma edge. The neutral energy spectrum in the lower energy range is strongly pronounced by this effect

  8. Imaging Plasma Density Structures in the Soft X-Rays Generated by Solar Wind Charge Exchange with Neutrals

    Science.gov (United States)

    Sibeck, David G.; Allen, R.; Aryan, H.; Bodewits, D.; Brandt, P.; Branduardi-Raymont, G.; Brown, G.; Carter, J. A.; Collado-Vega, Y. M.; Collier, M. R.; Connor, H. K.; Cravens, T. E.; Ezoe, Y.; Fok, M.-C.; Galeazzi, M.; Gutynska, O.; Holmström, M.; Hsieh, S.-Y.; Ishikawa, K.; Koutroumpa, D.; Kuntz, K. D.; Leutenegger, M.; Miyoshi, Y.; Porter, F. S.; Purucker, M. E.; Read, A. M.; Raeder, J.; Robertson, I. P.; Samsonov, A. A.; Sembay, S.; Snowden, S. L.; Thomas, N. E.; von Steiger, R.; Walsh, B. M.; Wing, S.

    2018-06-01

    Both heliophysics and planetary physics seek to understand the complex nature of the solar wind's interaction with solar system obstacles like Earth's magnetosphere, the ionospheres of Venus and Mars, and comets. Studies with this objective are frequently conducted with the help of single or multipoint in situ electromagnetic field and particle observations, guided by the predictions of both local and global numerical simulations, and placed in context by observations from far and extreme ultraviolet (FUV, EUV), hard X-ray, and energetic neutral atom imagers (ENA). Each proposed interaction mechanism (e.g., steady or transient magnetic reconnection, local or global magnetic reconnection, ion pick-up, or the Kelvin-Helmholtz instability) generates diagnostic plasma density structures. The significance of each mechanism to the overall interaction (as measured in terms of atmospheric/ionospheric loss at comets, Venus, and Mars or global magnetospheric/ionospheric convection at Earth) remains to be determined but can be evaluated on the basis of how often the density signatures that it generates are observed as a function of solar wind conditions. This paper reviews efforts to image the diagnostic plasma density structures in the soft (low energy, 0.1-2.0 keV) X-rays produced when high charge state solar wind ions exchange electrons with the exospheric neutrals surrounding solar system obstacles. The introduction notes that theory, local, and global simulations predict the characteristics of plasma boundaries such the bow shock and magnetopause (including location, density gradient, and motion) and regions such as the magnetosheath (including density and width) as a function of location, solar wind conditions, and the particular mechanism operating. In situ measurements confirm the existence of time- and spatial-dependent plasma density structures like the bow shock, magnetosheath, and magnetopause/ionopause at Venus, Mars, comets, and the Earth. However, in situ

  9. Charge exchange of hydrogen atoms with multiply charged ions in a hot plasma

    International Nuclear Information System (INIS)

    Abramov, V.A.; Baryshnikov, F.F.; Lisitsa, V.S.

    1980-08-01

    The symmetry properties of the hydrogen atom are used to calculate the charge exchange cross-sections sigma of hydrogen with the nuclei of multiply charged ions, allowance being made for the degeneration of final states. If the transitions between these states produced by rotation of the internuclear axis are taken into account, there is a qualitative change in the dependence of sigma on v for low values of v (a gradual decrease in the cross-section instead of the exponential one in the Landau-Zener model) and also a considerable increase in the peak cross-section. The cross-sections are calculated for a wide range of velocities and charge values Z. It is shown that the cross-section may be approximated to within approximately 9 /v).10 -15 cm 2 for Z>=18 (v in cm/s). A detailed comparison with the calculations of various authors is performed. The distribution of final states over orbital angular momenta is found. A calculation is made of variation in the spectral line intensities of the ion O +7 with injection of a neutral hydrogen beam in conditions similar to the experimental conditions on the ORMAK facility. (author)

  10. Separation of gold, palladium and platinum in chromite by anion exchange chromatography for inductively coupled plasma atomic emission spectrometric analysis

    International Nuclear Information System (INIS)

    Choi, Kwang Soon; Lee, Chang Heon; Park, Yeong Jae; Joe, Kih Soo; Kim, Won Ho

    2001-01-01

    A study has been carried out on the separation of gold, iridium, palladium, rhodium, ruthenium and platinum in chromite samples and their quantitative determination using inductively coupled plasma atomic emission spectrometry (ICP-AES). The dissolution condition of the minerals by fusion with sodium peroxide was optimized and chromatographic elution behavior of the rare metals was investigated by anion exchange chromatography. Spectral interference of chromium, a matrix of the minerals, was investigated on determination of gold. Chromium interfered on determination of gold at the concentration of 500 mg/L and higher. Gold plus trace amounts of iridium, palladium, rhodium and ruthenium, which must be preconcentrated before ICP-AES was separated by anion exchange chromatography after reducing Cr(VI) to Cr(III) by H 2 O 2 . AuCl - 4 retained on the resin column was selectively eluted with acetone- HNO 3 -H 2 O as an eluent. In addition, iridium, palladium, rhodium and ruthenium remaining on the resin column were eluted as a group with concentrated HCl. However, platinum was eluted with concentrated HNO 3 . The recovery yield of gold with acetone-HNO 3 -H 2 O was 100.7 ± 2.0 % , and the yields of palladium and platinum with concentrated HCl and HNO 3 were 96.1 ± 1.8% and 96.6 ± 1.3%, respectively. The contents of gold and platinum in a Mongolian chromite sample were 32.6 ± 2.2 μg/g and 1.6 ± 0.14 μg/g, respectively. Palladium was not detected

  11. Characterization of a PEGylated protein therapeutic by ion exchange chromatography with on-line detection by native ESI MS and MS/MS.

    Science.gov (United States)

    Muneeruddin, K; Bobst, C E; Frenkel, R; Houde, D; Turyan, I; Sosic, Z; Kaltashov, I A

    2017-01-16

    Detailed profiling of both enzymatic (e.g., glycosylation) and non-enzymatic (e.g., oxidation and deamidation) post-translational modifications (PTMs) is frequently required for the quality assessment of protein-based drugs. Challenging as it is, this task is further complicated for the so-called second-generation biopharmaceuticals, which also contain "designer PTMs" introduced to either enhance their pharmacokinetic profiles (e.g., PEGylated proteins) or endow them with therapeutic activity (e.g., protein-drug conjugates). Such modifications of protein covalent structure can dramatically increase structural heterogeneity, making the very notion of "molecular mass" meaningless, as ions representing different glycoforms of a PEGylated protein may have nearly identical distributions of ionic current as a function of m/z, making their contributions to the mass spectrum impossible to distinguish. In this work we demonstrate that a combination of ion exchange chromatography (IXC) with on-line detection by electrospray ionization mass spectrometry (ESI MS) and methods of ion manipulation in the gas phase (limited charge reduction and collision-induced dissociation) allows meaningful structural information to be obtained on a structurally heterogeneous sample of PEGylated interferon β-1a. IXC profiling of the protein sample gives rise to a convoluted chromatogram with several partially resolved peaks which can represent both deamidation and different glycosylation patterns within the protein, as well as varying extent of PEGylation. Thus, profiling the protein with on-line IXC/ESI/MS/MS allows it to be characterized by providing information on three different types of PTMs (designer, enzymatic and non-enzymatic) within a single protein therapeutic.

  12. Experimental investigation on electrical characteristics and dose measurement of dielectric barrier discharge plasma device used for therapeutic application.

    Science.gov (United States)

    Shahbazi Rad, Zahra; Abbasi Davani, Fereydoun

    2017-04-01

    In this research, a Dielectric Barrier Discharge (DBD) plasma device operating in air has been made. The electrical characteristics of this device like instantaneous power, dissipated power, and discharge capacitance have been measured. Also, the effects of applied voltage on the dissipated power and discharge capacitance of the device have been investigated. The determination of electrical parameters is important in DBD plasma device used in living tissue treatment for choosing the proper treatment doses and preventing the destructive effects. The non-thermal atmospheric pressure DBD plasma source was applied for studying the acceleration of blood coagulation time, in vitro and wound healing time, in vivo. The citrated blood drops coagulated within 5 s treatment time by DBD plasma. The effects of plasma temperature and electric field on blood coagulation have been studied as an affirmation of the applicability of the constructed device. Also, the effect of constructed DBD plasma on wound healing acceleration has been investigated.

  13. Charge-exchange diagnostic of fusion alpha particles and ICRF driven minority ions in MeV energy range in JET plasma

    International Nuclear Information System (INIS)

    Izvozchikov, A.B.; Khudoleev, A.V.; Petrov, M.P.; Petrov, S.Ya.; Kozlovskij, S.S.; Corti, S.; Gondahalekar, A.

    1991-12-01

    An important concern in alpha particle heating physics is that fusion alpha particles will be lost before giving all their energy to heat the plasma. In other words, that the radial diffusion time of the alphas may be shorter than their slowing down time in the plasma core. Therefore radially resolved measurements of density and energy spectrum of slowing-down alphas confined in the plasma are high priority diagnostic objectives. In this report application of Charge Exchange Neutral Particle Analysis on Joint European Torus will be discussed. After a description of physical principles of the method a suitable Neutral Particle Analyzer (NPA) will be described in detail and estimates of measurement performance made for different plasma heating and confinement modes in JET. (author)

  14. Analyte-Size-Dependent Ionization and Quantification of Monosaccharides in Human Plasma Using Cation-Exchanged Smectite Layers.

    Science.gov (United States)

    Ding, Yuqi; Kawakita, Kento; Xu, Jiawei; Akiyama, Kazuhiko; Fujino, Tatsuya

    2015-08-04

    Smectite, a synthetic inorganic polymer with a saponite structure, was subjected to matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS). Typical organic matrix molecules 2,4,6-trihydroxyacetophenone (THAP) and 2,5-dihydroxybenzoic acid (DHBA) were intercalated into the layer spacing of cation-exchanged smectite, and the complex was used as a new matrix for laser desorption/ionization mass spectrometry. Because of layer spacing limitations, only a small analyte that could enter the layer and bind to THAP or DHBA could be ionized. This was confirmed by examining different analyte/matrix preparation methods and by measuring saccharides with different molecular sizes. Because of the homogeneous distribution of THAP molecules in the smectite layer spacing, high reproducibility of the analyte peak intensity was achieved. By using isotope-labeled (13)C6-d-glucose as the internal standard, quantitative analysis of monosaccharides in pretreated human plasma sample was performed, and the value of 8.6 ± 0.3 μg/mg was estimated.

  15. The dose of nafamostat mesilate during plasma exchange with continuous hemodiafiltration in the series-parallel circuit.

    Science.gov (United States)

    Nakae, Hajime; Igarashi, Toshiko; Tajimi, Kimitaka

    2006-06-01

    We studied nafamostat mesilate (NM) and interleukin (IL)-18 levels to determine whether the dose of NM is reduced during plasma exchange (PE) with continuous hemodiafiltration (CHDF) when the series-parallel circuit is used. The subjects of the current study included four patients with acute hepatic failure who underwent PE with CHDF. The four patients underwent a total 15 PE + CHDF procedures, and for each procedure, they were randomized to receive either a half-dose of NM or no NM in the CHDF circuit. Eight procedures were carried out with NM administration, and seven were carried out without NM administration. The dose of NM in the NM group was significantly higher than that in the non-NM group (P = 0.040). No significant differences were observed between the two groups in the inlet NM concentration, the outlet NM concentration, or the rate of IL-18 removal. No statistical correlation was observed between the IL-18 level and the NM dose, the inlet NM concentration, or the outlet NM concentration. There was no blood access difficulty such as catheter failure or clotting of the filter. Thus, it might be possible to carry out PE and CHDF with the series-parallel method without administration of NM in the CHDF circuit.

  16. Plasma glucosylceramide and ceramide in type 1 Gaucher disease patients: correlations with disease severity and response to therapeutic intervention

    NARCIS (Netherlands)

    Groener, J. E. M.; Poorthuis, B. J. H. M.; Kuiper, S.; Hollak, C. E. M.; Aerts, J. M. F. G.

    2008-01-01

    The concentrations of plasma glucosylceramide (GlcCer) and ceramide (Cer) were determined in a cohort of type 1 Gaucher disease patients. In plasma of untreated patients, GlcCer concentrations were on average 3-fold increased (median Gaucher: 17.5 nmol/ml, range: 6.5-45.5 (n=27); median control: 5.9

  17. Line-emission cross sections for the charge-exchange reaction between fully stripped carbon and atomic hydrogen in tokamak plasma

    International Nuclear Information System (INIS)

    Ida, K.; Kato, T.

    1992-01-01

    Line-emission cross sections of the charge-exchange reaction between fully stripped carbon and atomic hydrogen are measured in the energy range of 18 - 38 keV/amu in tokamak plasmas. The energy dependence of the emission cross sections for the transition of Δn = 8 - 7 and Δn = 7 - 6 and their ratios are compared with theoretical calculations. (author)

  18. Variation in sister chromatid exchange frequencies between human and pig whole blood, plasma leukocyte, and mononuclear leukocyte cultures

    International Nuclear Information System (INIS)

    Larramendy, M.L.; Reigosa, M.A.

    1986-01-01

    Sister chromatid exchange (SCE) induction by ultraviolet (UV) light was studied in both human and pig whole blood cultures (WBC) and plasma leukocyte cultures (PLC). No variation in SCE frequency was observed between pig WBC and PLC in control as well as in treated cells. Conversely, SCE frequencies of human PLC were consistently higher than those of WBC in control and UV-exposed cells. Thus, red blood cells (RBCs) do not influence the sensitivity of lymphocytes to UV LIGHT exposure, and there must be some different culture condition(s) in the inducation of SCEs between human WBC and PLC but not in swine lymphocyte cultures. Since the BrdUrd/lymphocyte ratio of WBC was halved in PLC, the effect of BrdUrd concentration in inducing the SCE baseline frequency of PLC may be ruled out. Neither the cell separation technique nor polymorphonuclear leukocytes had a significant role in the elevated SCE frequency of human PLC or MLC. Experiments where human RBCs were titrated into human PLC showed that the induction of an elevated SCE frequency of PLC was suppressed in a dose-dependent manner by the presence of RBCs in the culture medium. Since the incorporation of pig or human RBCs into human PLC as well as into MLC reduced the SCE frequency to that of WBC, a common component and/or function existing in these cells is suggested. Analysis of different RBC components showed that RBCs, specifically RBC ghosts, release a diffusible but not dialyzable corrective factor into culture medium that is able to reduce the SCE frequencies of PLC

  19. Effectiveness of combining plasma exchange with continuous hemodiafiltration on acute Fatty liver of pregnancy complicated by multiple organ dysfunction.

    Science.gov (United States)

    Chu, Yu-Feng; Meng, Mei; Zeng, Juan; Zhou, Hai-Yan; Jiang, Jin-Jiao; Ren, Hong-Sheng; Zhang, Ji-Cheng; Zhu, Wen-Ying; Wang, Chun-Ting

    2012-06-01

    Acute fatty liver of pregnancy (AFLP) is a rare disease of progressive hepatic insufficiency and secondary systemic complications that induce significant maternal risk. The application of combining plasma exchange (PE) and continuous hemodiafiltration (CHDF) is a novel concept for patients with AFLP. Since 2002, we have utilized the combination of PE with CHDF as adjunctive medical therapy for 11 AFLP patients with multiple organ dysfunction. Before PE and CHDF initiation, four patients had signs and symptoms of encephalopathy, four required ventilatory support, and all 11 were developing liver failure, significant renal compromise, and coagulopathy. PE combined with CHDF for patients was initiated a mean of 2 days postpartum (range, days 0-3). Daily or every other day PE combined with CHDF was undertaken on two to eight occasions for each of the 11 patients. Ten patients responded with composite clinical and laboratory improvement and were discharged to the ward, then cured and discharged from hospital; one patient died of septic shock. Average duration of hospitalization was 17 days (range, days 9-38) from time of admission to discharge; the average duration of intensive care unit was 10 days (range, days 4-23). No significant PE- and CHDF-related complications occurred. These results indicate that combing PE and CHDF in a series-parallel circuit is an effective and safe treatment for patients with severe AFLP. This finding may have important implications for the development of an effective treatment for patients with AFLP suffering multiple organ dysfunction. © 2012, Copyright the Authors. Artificial Organs © 2012, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  20. [Comparison of curative effect of low flow rate plasma exchange combined with hemofiltration for treatment of liver failure].

    Science.gov (United States)

    Yang, Yong-feng; Huang, Ping; Zhang, Ning; Gai, Xiao-dong; Feng, Xiao-ning; Zhong, Yan-dan; Wang, Li-rong; Yang, Yi-jun; Zhao, Wei

    2009-02-01

    To investigate the effect of plasma exchange (PE) combined with hemofiltration (HF) on liver failure. Seventy-seven inpatients with liver failure admitted during January 2006 to August 2007 were randomly assigned to receive PE combined with HF (PE+HF group, 38 cases), or PE alone (PE group, 39 cases). Forty-one inpatients with liver failure who had not received artificial liver support treatment were assigned to serve as control group. The survival rates and biochemical parameters of three groups were compared. There was no significant difference in biochemical parameters before treatment among three groups. Compared with pre-treatment values, albumin (Alb), cholinesterase (ChE) and prothrombin activity (PTA) of both PE group and PE+HF group were significantly increased after treatment, and total bilirubin (TBIL), alanine transaminase (ALT), aspartate transaminase (AST) of both PE group and PE+HF group were significantly decreased after treatment (Prate of PE group, PE+HF group and control group was 48.7% (19/39), 68.4% (26/38), and 29.3% (12/41) respectively. The survival rate of PE+HF group was significantly higher than that of control group (chi(2)=12.11, Prate of recovery of consciousness of patients with hepatic encephalopathy in PE+HF group was higher than that of PE group (42.8% vs. 0, P<0.05). Compared with PE alone, the result was better when it was combined with HF in correction of electrolyte disturbance and acid-base imbalance (19/23 vs. 0/21, P<0.05). Treatment of liver failure by PE combined with HF is safe and effective, and its efficacy is higher than PE alone.

  1. Effects of weakly coupled and dense quantum plasmas environments on charge exchange and ionization processes in Na+ + Rb(5s) atom collisions

    Science.gov (United States)

    Pandey, Mukesh Kumar; Lin, Yen-Chang; Ho, Yew Kam

    2017-02-01

    The effects of weakly coupled or classical and dense quantum plasmas environment on charge exchange and ionization processes in Na+ + Rb(5s) atom collision at keV energy range have been investigated using classical trajectory Monte Carlo (CTMC) method. The interaction of three charged particles are described by the Debye-Hückel screen potential for weakly coupled plasma, whereas exponential cosine-screened Coulomb potential have been used for dense quantum plasma environment and the effects of both conditions on the cross sections are compared. It is found that screening effects on cross sections in high Debye length condition is quite small in both plasma environments. However, enhanced screening effects on cross sections are observed in dense quantum plasmas for low Debye length condition, which becomes more effective while decreasing the Debye length. Also, we have found that our calculated results for plasma-free case are comparable with the available theoretical results. These results are analyzed in light of available theoretical data with the choice of model potentials.

  2. Integrative analysis reveals CD38 as a therapeutic target for plasma cell-rich pre-disease and established rheumatoid arthritis and systemic lupus erythematosus.

    Science.gov (United States)

    Cole, Suzanne; Walsh, Alice; Yin, Xuefeng; Wechalekar, Mihir D; Smith, Malcolm D; Proudman, Susanna M; Veale, Douglas J; Fearon, Ursula; Pitzalis, Costantino; Humby, Frances; Bombardieri, Michele; Axel, Amy; Adams, Homer; Chiu, Christopher; Sharp, Michael; Alvarez, John; Anderson, Ian; Madakamutil, Loui; Nagpal, Sunil; Guo, Yanxia

    2018-05-02

    Plasmablasts and plasma cells play a key role in many autoimmune diseases, such as rheumatoid arthritis (RA) and systemic lupus erythematosus (SLE). This study was undertaken to evaluate the potential of targeting CD38 as a plasma cell/plasmablast depletion mechanism by daratumumab in the treatment of patients with RA and SLE. RNA-sequencing analysis of synovial biopsies from various stages of RA disease progression, flow cytometry analysis of peripheral blood mononuclear cells (PBMC) from patients with RA or SLE and healthy donors, immunohistochemistry assessment (IHC) of synovial biopsies from patients with early RA, and ex vivo immune cell depletion assays using daratumumab (an anti-CD38 monoclonal antibody) were used to assess CD38 as a therapeutic target. We demonstrated that the plasma cell/plasmablast-related genes CD38, XBP1, IRF4, PRDM1, IGJ and TNFSF13B are significantly up-regulated in synovial biopsies from patients with arthralgia, undifferentiated arthritis (UA), early RA and established RA as compared to healthy controls and control patients with osteoarthritis. In addition, the highest CD38 expression was observed on plasma cells and plasmablasts compared to natural killer (NK) cells, classical dendritic cells (DCs), plasmacytoid DCs (pDCs) and T cells, in blood from healthy controls and patients with SLE and RA. Furthermore, IHC showed CD38 staining in the same region as CD3 and CD138 staining in synovial tissue biopsies from patients with early RA. Most importantly, our data show for the first time that daratumumab effectively depletes plasma cells/plasmablasts in PBMC from patients with SLE and RA in a dose-dependent manner ex vivo. These results indicate that CD38 may be a potential target for RA disease interception and daratumumab should be evaluated clinically for the treatment of both RA and SLE.

  3. How do we reduce plasma transfusion in Rhode Island?

    Science.gov (United States)

    Nixon, Christian P; Tavares, Maria F; Sweeney, Joseph D

    2017-08-01

    Plasma transfusions are given to patients with coagulopathy, either prophylactically, before an invasive procedure; or therapeutically, in the presence of active bleeding; and as an exchange fluid in therapeutic plasma exchange for disorders such as thrombotic thrombocytopenic purpura. There is consensus that many prophylactic plasma transfusions are non-efficacious, and the misdiagnosis of thrombotic thrombocytopenic purpura results in unnecessary therapeutic plasma exchange. Beginning in 2001, programs to reduce plasma transfusion in the three major teaching hospitals in Rhode Island were initiated. The programs evolved through the establishment of guidelines, education for key prescribers of plasma, screening of plasma prescriptions, and engagement of individual prescribing physicians for out-of-guidelines prescriptions with modification or cancellation. Establishment of an in-house ADAMTS13 (ADAM metallopeptidase with thrombospondin type 1, motif 13) assay in 2013 was used to prevent therapeutic plasma exchange in patients with non-thrombotic thrombocytopenic purpura microangiopathy. Transfusion service data were gathered at the hospital level regarding blood component use, hospital data for discharges, inpatient mortality, and mean case-mix index, and, at the state level, for units of plasma shipped from the community blood center to in-state hospitals. Between 2006 and 2016, a reduction in plasma use from 11,805 to 2677 units (a 77% decrease) was observed in the three hospitals and was mirrored in the state as a whole. This decline was not associated with any increase in red blood cell transfusion. Inpatient mortality either declined or was unchanged. An active program focused on education and interdiction can achieve a large decrease in plasma transfusions without evidence of patient harm. © 2017 AABB.

  4. Organizing the Donation of Convalescent Plasma for a Therapeutic Clinical Trial on Ebola Virus Disease: The Experience in Guinea.

    Science.gov (United States)

    Delamou, Alexandre; Haba, Nyankoye Yves; Mari-Saez, Almudena; Gallian, Pierre; Ronse, Maya; Jacobs, Jan; Camara, Bienvenu Salim; Kadio, Kadio Jean-Jacques Olivier; Guemou, Achille; Kolie, Jean Pe; Crop, Maaike De; Chavarin, Patricia; Jacquot, Chantal; Lazaygues, Catherine; Weggheleire, Anja De; Lynen, Lutgarde; van Griensven, Johan

    2016-09-07

    Although convalescent plasma (CP) transfusion was prioritized among potential Ebola treatments by the World Health Organization, there were concerns on the feasibility of its implementation. We report on the successful organization of donor mobilization and plasma collection as part of the Ebola-Tx clinical trial from November 2014 to July 2015 in Conakry, Guinea. Project implementation registers, tools and reports, mission reports, and minutes of research team meetings were used to reconstruct the sequence of events on how donor mobilization was organized, plasmapheresis was set up, and how effective this approach was in collecting CP. An initial needs assessment of the Guinean National Blood Transfusion Center resulted in targeted training of staff on site, resulting in autonomy and independent production of CP within 3 months. The Conakry Ebola Survivors Association played a direct role in donor mobilization and organization of CP donations. A total of 98 Ebola survivors were screened for plasma donation, of which 84 were found eligible for plasmapheresis. Of these, 26 (30.9%) were excluded. The remaining 58 donors made a total of 90 donations, corresponding to 50.9 L of CP. This sufficed to treat the 99 eligible patients enrolled in the trial. Within a poor resource emergency context, transfusion capacity could be rapidly improved through the strengthening of local capacities and gradual transfer of skills coupled with active involvement of Ebola survivors. However, large-scale plasma collection or multisite studies may require further adaptations of both strategy and logistics. The Ebola-Tx trial was funded by the European Union and others. © The American Society of Tropical Medicine and Hygiene.

  5. Organizing the Donation of Convalescent Plasma for a Therapeutic Clinical Trial on Ebola Virus Disease: The Experience in Guinea

    Science.gov (United States)

    Delamou, Alexandre; Haba, Nyankoye Yves; Mari-Saez, Almudena; Gallian, Pierre; Ronse, Maya; Jacobs, Jan; Camara, Bienvenu Salim; Kadio, Kadio Jean-Jacques Olivier; Guemou, Achille; Kolie, Jean Pe; De Crop, Maaike; Chavarin, Patricia; Jacquot, Chantal; Lazaygues, Catherine; De Weggheleire, Anja; Lynen, Lutgarde; van Griensven, Johan

    2016-01-01

    Although convalescent plasma (CP) transfusion was prioritized among potential Ebola treatments by the World Health Organization, there were concerns on the feasibility of its implementation. We report on the successful organization of donor mobilization and plasma collection as part of the Ebola-Tx clinical trial from November 2014 to July 2015 in Conakry, Guinea. Project implementation registers, tools and reports, mission reports, and minutes of research team meetings were used to reconstruct the sequence of events on how donor mobilization was organized, plasmapheresis was set up, and how effective this approach was in collecting CP. An initial needs assessment of the Guinean National Blood Transfusion Center resulted in targeted training of staff on site, resulting in autonomy and independent production of CP within 3 months. The Conakry Ebola Survivors Association played a direct role in donor mobilization and organization of CP donations. A total of 98 Ebola survivors were screened for plasma donation, of which 84 were found eligible for plasmapheresis. Of these, 26 (30.9%) were excluded. The remaining 58 donors made a total of 90 donations, corresponding to 50.9 L of CP. This sufficed to treat the 99 eligible patients enrolled in the trial. Within a poor resource emergency context, transfusion capacity could be rapidly improved through the strengthening of local capacities and gradual transfer of skills coupled with active involvement of Ebola survivors. However, large-scale plasma collection or multisite studies may require further adaptations of both strategy and logistics. The Ebola-Tx trial was funded by the European Union and others. PMID:27430546

  6. Population pharmacokinetics of piperacillin in the early phase of septic shock – does standard dosing result in therapeutic plasma concentrations?

    DEFF Research Database (Denmark)

    Öbrink-Hansen, Kristina Margareta; Juul, Rasmus Vestergaard; Storgaard, Merete

    2015-01-01

    using NONMEM and data was best described by a two-compartment model. Central and inter-compartmental clearances were 3.6 L/h (RSE 15.7%) and 6.58 (16.4%), and central and peripheral volumes were 7.3 L (RSE 11.8 %) and 3.9 L (RSE 9.7%), respectively. Piperacillin plasma concentrations varied considerably...

  7. 2nd (final) IAEA research co-ordination meeting on 'charge exchange cross section data for fusion plasma studies'. Summary report

    International Nuclear Information System (INIS)

    Clark, R.E.H.

    2001-11-01

    The proceedings and conclusions of the 2nd Research Co-ordination Meeting on 'Charge Exchange Cross Section Data for Fusion Plasma Studies', held on September 25 and 26, 2000 at the IAEA Headquarters in Vienna, are briefly described. This report includes a summary of the presentations made by the meeting participants and a review of the accomplishments of the Co-ordinated Research Project (CRP). In addition, short summaries from the participants are included indicating the specific research completed in support of this CRP. (author)

  8. Therapeutic effects of marshmallow (Althaea officinalis L.) extract on plasma biochemical parameters of common carp infected with Aeromonas hydrophila.

    Science.gov (United States)

    Banaee, Mahdi; Soleimany, Vahid; Nematdoost Haghi, Behzad

    2017-01-01

    This study evaluated preclinical and clinical safety of marshmallow ( Althaea officinalis L.) extract as a naturopathic medicine in common carp deliberately infected with Aeromonas hydrophila . The fish were fed 0 (control), 2.50, 5.00 and 10.00 g of marshmallow extract for 60 days in a preclinical experiment and then, challenged with A. hydrophila for a 10-day experiment. Significant increases were observed in aspartate aminotransferase (AST), lactate dehydrogenase (LDH), alkaline phosphatase (ALP), creatine phosphokinase (CPK) activities and plasma creatinine levels in fish fed 10 g marshmallow extract per kg feed. However, alanine aminotransferase (ALT) significantly decreased on day 60. The fish fed 2.50 g marshmallow extract per kg feed indicated increased levels of total protein and globulin. There were no significant changes in albumin levels ( p > 0.05). 2.50 and 5.00 g marshmallow significantly decreased triglyceride and cholesterol levels and increased glucose levels ( p Marshmallow extract at 5.00 and 10.00 g can adjust plasma biochemical parameters in fish challenged with A. hydrophila . The results of preclinical studies and pharmaceutical toxicity of marshmallow extract revealed that dietary levels lower than 5.00 g were safe and effective. The results of this clinical study demonstrated that marshmallow extract (5.00 g kg -1 feed) can protect fish against A. hydrophila .

  9. Application of cation-exchange solid-phase extraction for the analysis of amino alcohols from water and human plasma for verification of Chemical Weapons Convention.

    Science.gov (United States)

    Kanaujia, Pankaj K; Tak, Vijay; Pardasani, Deepak; Gupta, A K; Dubey, D K

    2008-03-28

    The analysis of nitrogen containing amino alcohols, which are the precursors and degradation products of nitrogen mustards and nerve agent VX, constitutes an important aspect for verifying the compliance to the CWC (Chemical Weapons Convention). This work devotes on the development of solid-phase extraction method using silica- and polymer-based SCX (strong cation-exchange) and MCX (mixed-mode strong cation-exchange) cartridges for N,N-dialkylaminoethane-2-ols and alkyl N,N-diethanolamines, from water. The extracted analytes were analyzed by GC-MS (gas chromatography-mass spectrometry) in the full scan and selected ion monitoring modes. The extraction efficiencies of SCX and MCX cartridges were compared, and results revealed that SCX performed better. Extraction parameters, such as loading capacity, extraction solvent, its volume, and washing solvent were optimized. Best recoveries were obtained using 2 mL methanol containing 10% NH(4)OH and limits of detection could be achieved up to 5 x 10(-3) microg mL(-1) in the selected ion monitoring mode and 0.01 microg mL(-1) in full scan mode. The method was successfully employed for the detection and identification of amino alcohol present in water sample sent by Organization for Prohibition of Chemical Weapons (OPCW) in the official proficiency tests. The method was also applied to extract the analytes from human plasma. The SCX cartridge showed good recoveries of amino alcohols from human plasma after protein precipitation.

  10. Simultaneous determination of platinum group elements and rhenium in rock samples using isotope dilution inductively coupled plasma mass spectrometry after cation exchange separation followed by solvent extraction

    International Nuclear Information System (INIS)

    Shinotsuka, Kazunori; Suzuki, Katsuhiko

    2007-01-01

    A simple and precise determination method for platinum group elements (PGEs) and Re in rock samples was developed using isotope dilution coupled with inductively coupled plasma mass spectrometry (ID-ICP-MS). Cation exchange separation was employed for simplicity, because it is applicable to group separation and simultaneous isotopic measurement in contrast with the widely used anion exchange separation which entails separate elution. However, its application to ID-ICP-MS has been limited due to spectral interferences from impurities retained in the PGE fraction even after ion chromatography. To overcome this limitation, solvent extraction using N-benzoyl-N-phenylhydroxylamine (BPHA) in chloroform was successfully applied for further purification. After the examination of optimum experimental parameters in cation exchange separation and solvent extraction using synthetic PGE solution, the established procedure was applied to the determination of PGEs and Re in some geochemical reference materials. The obtained results agreed well with the literature data determined using the different digestion methods (NiS fire assay and the use of a high-pressure asher) within the analytical uncertainties of each other. Significant difference in reproducibility between Ru, Ir, Pt and Os group, and Pd and Re group was observed in the results for BHVO-2 and JA-2. By considering the error factors affecting analytical reproducibility, we concluded that the difference is ascribed to the sample heterogeneity of minor minerals enriched in Ru, Ir, Pt and Os

  11. Therapeutic efficacy of connective tissue autotransplants with periosteum and platelet rich plasma in the management of gingival recession

    Directory of Open Access Journals (Sweden)

    Jovičić Bojan

    2013-01-01

    Full Text Available Background/Aim. Gingival recession progression in clinical practaice has influenced the development of various surgical procedures and techniques for solving esthetic imperfections and subjective difficulties coused by gingival recession. The aim of this study was to verify efficacy of surgical procedures and to compare both of surgical procedures through the keratinized tissue width. Methods. The study included 20 teeth with gingival recesion, Müller class I and II. Ten teeth with gingival recession were treated with connective tissue autotransplants with periosteum in combination with coronary guided surgical flap (CTG group. On the contralateral side 10 teeth with gingival recession were treated with the same surgical procedures but in combination with platelet-rich plasma (CTGPRP group. We measured the keratinized tissue width. For statistical significance we used the Student's t-test. Results. The study reveled a statistical significance in reducing vertical deepress of recession by both used treatments. Root deepness in CTG and CTG-PRP group was 90% and 93.5%, respectively. With both surgical techniques we achieved larger zone of keratinized gingiva but with a wide zone of keratinized tissue in CTG - the PRP group. Conclusion. The concept regeneration technique with PRP and with the stimulating influence of platele activated growth factors results in the regeneration of deep periodontal tissue as an important prerequisite for the successful treatment of gingival recession.

  12. Therapeutic Plasmapheresis in Kidney Transplantation

    Directory of Open Access Journals (Sweden)

    Zeynep Kendi Celebi

    2013-02-01

    Full Text Available In 1960's, with succesfully renal transplantations, acute rejection became to be a serious problem for graft survival. From 1965 to 2010, with the introduction of new immunosuppressant agents such as cyclosporine, mycophenolate mofetile and tacrolimus, the acute rejection rates declined from 80% to 10% . There is an ongoing gradual improvement in allograft survival. Use of Therapeutic plasma exchange (TPE is not evidence based treatment, but TPE is necessary for pre- and also post transplantation in patients with DSA. TPE is also a main treatment for antibody mediated rejection (AMR , but in clinical practice the duration and frequency of TPE and individual difference of antibody production is unclear. There is a requirement for more specific antibody elimination. Further randomised controlled studies are needed to elucidate TPE use before and after kidney transplantation. [Dis Mol Med 2013; 1(1.000: 8-10

  13. Filtration as the main transport mechanism of protein exchange between plasma and the peritoneal cavity in hepatic cirrhosis

    DEFF Research Database (Denmark)

    Henriksen, J H; Lassen, N A; Parving, H H

    1980-01-01

    Fractional peritoneal reabsorption rates (FPRR) were determined from the plasma activity after simultaneous intraperitoneal injection of 131I-labelled serum albumin (a) and 125I-labelled immunoglobulin G-IgG (g) in eight patients with cirrhosis (+ ascites 6, -ascites 2) and in one patient...... with carcinomatous ascites. Trans-vascular escape rates of albumin (TERa) and IgG (TERg) were determined in the cirrhotic patients from the disappearance of simultaneously intravenously injected 131I-labelled serum albumin and 124I-labelled IgG. Peritoneal space to plasma appearance times ranged 0.1-3.3 h......, and the appearance times of albumin and IgG were almost identical. In patients with cirrhosis FPRRa and FPRRg were on average 1.27 and 1.21% of intraperitoneal protein masses returning to plasma per hour, respectively. Mean FPRRg/FPRRa ratio was 0.95 and this value was not significantly different from unity...

  14. Review of Langmuir-Wave-Caused Dips and Charge-Exchange-Caused Dips in Spectral Lines from Plasmas and their Applications

    Directory of Open Access Journals (Sweden)

    Elisabeth Dalimier

    2014-05-01

    Full Text Available We review studies of two kinds of dips in spectral line profiles emitted by plasmas—dips that have been predicted theoretically and observed experimentally: Langmuir-wave-caused dips (L-dips and charge-exchange-caused dips (X-dips. There is a principal difference with respect to positions of L-dips and X-dips relative to the unperturbed wavelength of a spectral line: positions of L-dips scale with the electron density Ne roughly as Ne1/2, while positions of X-dips are almost independent of Ne (the dependence is much weaker than for L-dips. L-dips and X-dips phenomena are important, both fundamentally and practically. The fundamental importance is due to a rich physics behind each of these phenomena. L-dips are a multi-frequency resonance phenomenon caused by a single-frequency (monochromatic electric field. X-dips are due to charge exchange at anticrossings of terms of a diatomic quasi-molecule, whose nuclei have different charges. As for important practical applications, they are as follows: observations of L-dips constitute a very accurate method to measure the electron density in plasmas—a method that does not require knowledge of the electron temperature. L-dips also allow measuring the amplitude of the electric field of Langmuir waves—the only spectroscopic method available for this purpose. Observations of X-dips provide an opportunity to determine rate coefficient of charge exchange between multi-charged ions. This is an important reference data, virtually inaccessible by other experimental methods. The rate coefficients of charge exchange are important for magnetic fusion in Tokamaks, for population inversion in the soft x-ray and VUV ranges, for ion storage devices, as well as for astrophysics (e.g., for the solar plasma and for determining the physical state of planetary nebulae.

  15. Effect of therapeutic plasma concentrations of non-steroidal anti-inflammatory drugs on the production of reactive oxygen species by activated rat neutrophils

    Directory of Open Access Journals (Sweden)

    Paino I.M.M.

    2005-01-01

    Full Text Available The release of reactive oxygen specie (ROS by activated neutrophil is involved in both the antimicrobial and deleterious effects in chronic inflammation. The objective of the present investigation was to determine the effect of therapeutic plasma concentrations of non-steroidal anti-inflammatory drugs (NSAIDs on the production of ROS by stimulated rat neutrophils. Diclofenac (3.6 µM, indomethacin (12 µM, naproxen (160 µM, piroxicam (13 µM, and tenoxicam (30 µM were incubated at 37ºC in PBS (10 mM, pH 7.4, for 30 min with rat neutrophils (1 x 10(6 cells/ml stimulated by phorbol-12-myristate-13-acetate (100 nM. The ROS production was measured by luminol and lucigenin-dependent chemiluminescence. Except for naproxen, NSAIDs reduced ROS production: 58 ± 2% diclofenac, 90 ± 2% indomethacin, 33 ± 3% piroxicam, and 45 ± 6% tenoxicam (N = 6. For the lucigenin assay, naproxen, piroxicam and tenoxicam were ineffective. For indomethacin the inhibition was 52 ± 5% and diclofenac showed amplification in the light emission of 181 ± 60% (N = 6. Using the myeloperoxidase (MPO/H2O2/luminol system, the effects of NSAIDs on MPO activity were also screened. We found that NSAIDs inhibited both the peroxidation and chlorinating activity of MPO as follows: diclofenac (36 ± 10, 45 ± 3%, indomethacin (97 ± 2, 100 ± 1%, naproxen (56 ± 8, 76 ± 3%, piroxicam (77 ± 5, 99 ± 1%, and tenoxicam (90 ± 2, 100 ± 1%, respectively (N = 3. These results show that therapeutic levels of NSAIDs are able to suppress the oxygen-dependent antimicrobial or oxidative functions of neutrophils by inhibiting the generation of hypochlorous acid.

  16. Successful Treatment of Focal Segmental Glomerulosclerosis after Kidney Transplantation with Plasma Exchange and Abatacept in a Patient with Juvenile Rheumatoid Arthritis

    Directory of Open Access Journals (Sweden)

    Hannelore Sprenger-Mähr

    2016-01-01

    Full Text Available Recurrent focal segmental glomerulosclerosis (FSGS after renal transplantation is difficult to treat. Recently a series of four patients unresponsive to plasma exchange (PE and rituximab, who were successfully treated with abatacept, has been reported. We present a 26-year-old Caucasian patient who suffered from juvenile rheumatoid arthritis and developed severe proteinuria eleven days after transplantation. An allograft biopsy was suggestive of recurrent focal segmental glomerulosclerosis. He did not respond to PE therapy. A first dose of abatacept produced partial remission. Four weeks later proteinuria again increased and a second biopsy showed progression of disease. After another ineffective course of PE he was given a second dose of abatacept, which was followed by rapid, complete, and sustained resolution of proteinuria. This treatment caused a significant increase in BK and JC viremia. Whether abatacept ameliorated proteinuria via an effect on podocytes or on the patient’s primary disease remains speculative.

  17. Postpartum plasma exchange in a woman with suspected thrombotic thrombocytopenic purpura (TTP) vs. hemolysis, elevated liver enzymes, and low platelet syndrome (HELLP): a case study.

    Science.gov (United States)

    Myers, Linda

    2010-01-01

    The occurrence of a hypercoagulable state and decreasing concentration of ADAMTS 13 in late pregnancy and during the postpartum period increases the risk for a woman to develop life-threatening thrombotic thrombocytopenic purpura (TTP). This is also the time of great risk for the more common obstetric complications of preeclampsia; eclampsia; and hemolysis, elevated liver functions tests, low platelets (HELLP) syndrome. These conditions are associated with high maternal and perinatal mortality. Differential diagnosis may be difficult due to the overlapping of clinical and laboratory findings, including thrombocytopenia, microangiopathic hemolytic anemia, neurologic symptoms, and renal insufficiency, making it difficult or impossible to distinguish them from TTP. Management of microangiopathic disorders encountered during pregnancy differ; therefore, an accurate diagnosis is required. Outcomes of TTP without plasma exchange therapy (TPE) are almost uniformly fatal. Early recognition and management of symptoms with prompt and aggressive TPE is essential when TTP is suspected.

  18. Filtration as the main transport mechanism of protein exchange between plasma and the peritoneal cavity in hepatic cirrhosis

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Lassen, N A; Parving, H H

    1980-01-01

    , but significantly higher (P rate was on average 61 ml/h. TERa and TERg were on average 9.6 and 8.6% of intravascular protein masses per hour, mean TERg/TERa ratio was 0.95. Peritoneal space......Fractional peritoneal reabsorption rates (FPRR) were determined from the plasma activity after simultaneous intraperitoneal injection of 131I-labelled serum albumin (a) and 125I-labelled immunoglobulin G-IgG (g) in eight patients with cirrhosis (+ ascites 6, -ascites 2) and in one patient...... with carcinomatous ascites. Trans-vascular escape rates of albumin (TERa) and IgG (TERg) were determined in the cirrhotic patients from the disappearance of simultaneously intravenously injected 131I-labelled serum albumin and 124I-labelled IgG. Peritoneal space to plasma appearance times ranged 0.1-3.3 h...

  19. The effect of insulin deficiency on the plasma clearance and exchange of high-density-lipoprotein phosphatidylcholine in rats.

    OpenAIRE

    Martins, I J; Redgrave, T G

    1992-01-01

    Triolein/cholesteryl oleate/cholesterol/phosphatidylcholine emulsions designed to model the lipid composition of chylomicrons were injected intravenously into control and streptozotocin-treated insulin-deficient rats. As previously described for lymph chylomicrons, the emulsion triolein was hydrolysed and phosphatidylcholine was transferred to the plasma high-density lipoproteins (HDL). This mechanism was used to introduce a phospholipid label into HDL in vivo. The subsequent clearance of pho...

  20. Development of the gas puff charge exchange recombination spectroscopy (GP-CXRS) technique for ion measurements in the plasma edge

    International Nuclear Information System (INIS)

    Churchill, R. M.; Theiler, C.; Lipschultz, B.; Dux, R.; Pütterich, T.; Viezzer, E.

    2013-01-01

    A novel charge-exchange recombination spectroscopy (CXRS) diagnostic method is presented, which uses a simple thermal gas puff for its donor neutral source, instead of the typical high-energy neutral beam. This diagnostic, named gas puff CXRS (GP-CXRS), is used to measure ion density, velocity, and temperature in the tokamak edge/pedestal region with excellent signal-background ratios, and has a number of advantages to conventional beam-based CXRS systems. Here we develop the physics basis for GP-CXRS, including the neutral transport, the charge-exchange process at low energies, and effects of energy-dependent rate coefficients on the measurements. The GP-CXRS hardware setup is described on two separate tokamaks, Alcator C-Mod and ASDEX Upgrade. Measured spectra and profiles are also presented. Profile comparisons of GP-CXRS and a beam based CXRS system show good agreement. Emphasis is given throughout to describing guiding principles for users interested in applying the GP-CXRS diagnostic technique

  1. Development of the gas puff charge exchange recombination spectroscopy (GP-CXRS) technique for ion measurements in the plasma edge

    Energy Technology Data Exchange (ETDEWEB)

    Churchill, R. M.; Theiler, C.; Lipschultz, B. [MIT Plasma Science and Fusion Center, Cambridge, Massachusetts 02139 (United States); Dux, R.; Pütterich, T.; Viezzer, E. [Max-Planck-Institut für Plasmaphysik, EURATOM Association, Boltzmannstrasse 2, D-85748 Garching (Germany); Collaboration: Alcator C-Mod Team; ASDEX Upgrade Team

    2013-09-15

    A novel charge-exchange recombination spectroscopy (CXRS) diagnostic method is presented, which uses a simple thermal gas puff for its donor neutral source, instead of the typical high-energy neutral beam. This diagnostic, named gas puff CXRS (GP-CXRS), is used to measure ion density, velocity, and temperature in the tokamak edge/pedestal region with excellent signal-background ratios, and has a number of advantages to conventional beam-based CXRS systems. Here we develop the physics basis for GP-CXRS, including the neutral transport, the charge-exchange process at low energies, and effects of energy-dependent rate coefficients on the measurements. The GP-CXRS hardware setup is described on two separate tokamaks, Alcator C-Mod and ASDEX Upgrade. Measured spectra and profiles are also presented. Profile comparisons of GP-CXRS and a beam based CXRS system show good agreement. Emphasis is given throughout to describing guiding principles for users interested in applying the GP-CXRS diagnostic technique.

  2. Experimental study on the influence of charge exchange on the stopping power in the interaction of chlorine with a gas and a deuterium plasma

    International Nuclear Information System (INIS)

    Nectoux, Marie

    1998-01-01

    This thesis is placed in the context of the physics of energy deposition of a multicharged heavy ion beam in matter at intermediate energies. The experiment gave measurements of energy loss as a function of final charge state for chlorine ions at 1.7 MeV/u in deuterium gas or plasma. In this way, we explore the influence of charge state evolution, depending on experimentally measured capture and ionization cross sections and the electron density of the target, on energy loss. The target is cylindrical and enclosed by two fast valves. The plasma is created in the gas by a discharge, which induces a magnetic perturbation of the beam (lens effect). This effect induces a divergent and misaligned outgoing beam. A simulation including charge state and velocity evolution of the projectile in flight in the magnetic field has been made in order to optimize beam analysis, to reach a precision better than 10 -3 in energy measurement. This study led to removal of the target to the 'Split Pole', a refocusing magnetic spectrometer. The first results obtained clearly show the dependence of energy loss on exit charge and especially on its evolution in the target. This is explained in terms of the lengths covered by the projectile in its successive charge states in the target, which depends on target electron density and the medium considered. In plasma, we observed an energy distribution with exit charge twice that observed in gas, because of a strong decrease of charge exchange. A comparison of data obtained in gas with stopping power calculated from Bethe-Bloch-Barkas theory leads to the necessity of including spatial extension of the projectile charge in the theory. (author)

  3. Economic analysis of intravenous immunoglobulin and plasma exchange therapies for the treatment of Guillain-Barré Syndrome in a university-based hospital in the South of Brazil

    Directory of Open Access Journals (Sweden)

    Alexandre Paulo Machado de Brito

    2011-10-01

    Full Text Available Introduction: Direct costs for treating Guillain-Barré Syndrome (GBS represent a significant financial burden to public hospitals. Few studies compared the cost of plasma exchange (PE treatment with human intravenous immunoglobulin (IVIg. Objectives: To compare the cost of two therapies for GBS: IVIg and PE. Secondary objective was to evaluate compliance to IVIg prescription guidelines of the Pharmacy and Therapeutics Committee (PTC. Methods: A cross-sectional study included 25 patients with GBS admitted in a university affiliated hospital from June, 2003 through June, 2008. The costs of IVIg (n=20 and PE (n=5 were evaluated through the cost minimization method, considering direct medical costs yield by the management of the institution. Patients receiving treatments other than PE or IVIg were excluded. Data were collected by medical records review. Clinical endpoint was disability on discharge, established by the 7-point scale of Hughes. Compliance to the PTC guidelines was evaluated considering the dose and prescription regime of IVIg. Results: Twenty-five participants, ranging from 2 to 70 years of age, were included. No difference occurred in any medical variables related to the treatment or in the main clinical outcome measured by the Hughes’ scale. The mean direct cost of PE treatment was US$ 6,059± 1,701 per patient, and the same expense for IVIg was US$ 18,344±12,259 (P = 0.035. Total inpatient cost was US$ 25,730± 18,714 in the PE group, and 34,768± 27,766 (p=0.530 in the IVIg group. Conclusions: In a university-based hospital, PE is equally effective and less expensive than IVIg to treat GBS.

  4. Measurements of confined alphas and tritons in the MHD quiescent core of TFTR plasmas using the pellet charge exchange diagnostic

    International Nuclear Information System (INIS)

    Medley, S.S.; Budny, R.V.; Mansfield, D.K.

    1996-05-01

    The energy distributions and radial density profiles of the fast confined trapped alpha particles in DT experiments on TFTR are being measured in the energy range 0.5--3.5 MeV using a Pellet Charge eXchange (PCX) diagnostic. A brief description of the measurement technique which involves active neutral particle analysis using the ablation cloud surrounding an injected impurity pellet as the neutralizer is presented. This paper focuses on alpha and triton measurements in the core of MHD quiescent TFTR discharges where the expected classical slowing down and pitch angle scattering effects are not complicated by stochastic ripple diffusion and sawtooth activity. In particular, the first measurement of the alpha slowing down distribution up to the birth energy, obtained using boron pellet injection, is presented. The measurements are compared with predictions using either the TRANSP Monte-Carlo code and/or a Fokker-Planck Post-TRANSP processor code, which assumes that the alphas and tritons are well confined and slow down classically. Both the shape of the measured alpha and triton energy distributions and their density ratios are in good agreement with the code calculations. The authors conclude that the PCX measurements are consistent with classical thermalization of the fusion-generated alphas and tritons

  5. Direct analysis of ultra-trace semiconductor gas by inductively coupled plasma mass spectrometry coupled with gas to particle conversion-gas exchange technique.

    Science.gov (United States)

    Ohata, Masaki; Sakurai, Hiromu; Nishiguchi, Kohei; Utani, Keisuke; Günther, Detlef

    2015-09-03

    An inductively coupled plasma mass spectrometry (ICPMS) coupled with gas to particle conversion-gas exchange technique was applied to the direct analysis of ultra-trace semiconductor gas in ambient air. The ultra-trace semiconductor gases such as arsine (AsH3) and phosphine (PH3) were converted to particles by reaction with ozone (O3) and ammonia (NH3) gases within a gas to particle conversion device (GPD). The converted particles were directly introduced and measured by ICPMS through a gas exchange device (GED), which could penetrate the particles as well as exchange to Ar from either non-reacted gases such as an air or remaining gases of O3 and NH3. The particle size distribution of converted particles was measured by scanning mobility particle sizer (SMPS) and the results supported the elucidation of particle agglomeration between the particle converted from semiconductor gas and the particle of ammonium nitrate (NH4NO3) which was produced as major particle in GPD. Stable time-resolved signals from AsH3 and PH3 in air were obtained by GPD-GED-ICPMS with continuous gas introduction; however, the slightly larger fluctuation, which could be due to the ionization fluctuation of particles in ICP, was observed compared to that of metal carbonyl gas in Ar introduced directly into ICPMS. The linear regression lines were obtained and the limits of detection (LODs) of 1.5 pL L(-1) and 2.4 nL L(-1) for AsH3 and PH3, respectively, were estimated. Since these LODs revealed sufficiently lower values than the measurement concentrations required from semiconductor industry such as 0.5 nL L(-1) and 30 nL L(-1) for AsH3 and PH3, respectively, the GPD-GED-ICPMS could be useful for direct and high sensitive analysis of ultra-trace semiconductor gas in air. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Plasma exchanges for severe acute neurological deterioration in patients with IgM anti-myelin-associated glycoprotein (anti-MAG) neuropathy.

    Science.gov (United States)

    Baron, M; Lozeron, P; Harel, S; Bengoufa, D; Vignon, M; Asli, B; Malphettes, M; Parquet, N; Brignier, A; Fermand, J P; Kubis, N; Arnulf, Bertrand

    2017-06-01

    Monoclonal IgM anti-myelin-associated glycoprotein (MAG) antibody-related peripheral neuropathy (anti-MAG neuropathy) is predominantly a demyelinating sensory neuropathy with ataxia and distal paresthesia. The clinical course of anti-MAG neuropathy is usually slowly progressive making difficult the identification of clear criteria to start a specific treatment. Although no consensus treatment is yet available, a rituximab-based regimen targeting the B-cell clone producing the monoclonal IgM may be proposed, alone or in combination with alkylating agents or purine analogs. However, in some rare cases, an acute and severe neurological deterioration can occur in few days leading to a rapid loss of autonomy. In these cases, a treatment rapidly removing the monoclonal IgM from the circulation might be useful before initiating a specific therapy. We report successful treatment with plasma exchanges (PE) in four patients presenting with acute neurological deterioration. PE allowed a dramatic and rapid neurological improvement in all patients. PE are safe and may be useful at the initial management of these cases of anti-MAG neuropathy.

  7. KB-R7943, a plasma membrane Na(+)/Ca(2+) exchanger inhibitor, blocks opening of the mitochondrial permeability transition pore.

    Science.gov (United States)

    Wiczer, Brian M; Marcu, Raluca; Hawkins, Brian J

    2014-01-31

    The isothiourea derivative, KB-R7943, inhibits the reverse-mode of the plasma membrane sodium/calcium exchanger and protects against ischemia/reperfusion injury. The mechanism through which KB-R7943 confers protection, however, remains controversial. Recently, KB-R7943 has been shown to inhibit mitochondrial calcium uptake and matrix overload, which may contribute to its protective effects. While using KB-R7943 for this purpose, we find here no evidence that KB-R7943 directly blocks mitochondrial calcium uptake. Rather, we find that KB-R7943 inhibits opening of the mitochondrial permeability transition pore in permeabilized cells and isolated liver mitochondria. Furthermore, we find that this observation correlates with protection against calcium ionophore-induced mitochondrial membrane potential depolarization and cell death, without detrimental effects to basal mitochondrial membrane potential or complex I-dependent mitochondrial respiration. Our data reveal another mechanism through which KB-R7943 may protect against calcium-induced injury, as well as a novel means to inhibit the mitochondrial permeability transition pore. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Simultaneous separation and determination of six arsenic species in rice by anion-exchange chromatography with inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Ma, Li; Yang, Zhaoguang; Tang, Jie; Wang, Lin

    2016-06-01

    The simultaneous separation and determination of arsenite As(III), arsenate As(V), monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), arsenobetaine (AsB), and arsenocholine (AsC) in rice samples have been carried out in one single anion-exchange column run by high-performance liquid chromatography with inductively coupled plasma mass spectrometry. To estimate the effect of variables on arsenic (As) speciation, the chromatographic conditions including type of competing anion, ionic strength, pH of elution buffer, and flow rate of mobile phase have been investigated by a univariate approach. Under the optimum chromatographic conditions, baseline separation of six As species has been achieved within 10 min by gradient elution program using 4 mM NH4 HCO3 at pH 8.6 as mobile phase A and 4 mM NH4 HCO3 , 40 mM NH4 NO3 at pH 8.6 as mobile phase B. The method detection limits for As(III), As(V), MMA, DMA, AsB, and AsC were 0.4, 0.9, 0.2, 0.4, 0.5, and 0.3 μg/kg, respectively. The proposed method has been applied to separation and quantification of As species in real rice samples collected from Hunan Province, China. The main As species detected in all samples were As(III), As(V) and DMA, with inorganic As accounting for over 80% of total As in these samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. The effect of plasma exchange on entecavir-treated chronic hepatitis B patients with hepatic de-compensation and acute-on-chronic liver failure.

    Science.gov (United States)

    Yue-Meng, Wan; Yang, Li-Hong; Yang, Jin-Hui; Xu, Ying; Yang, Jing; Song, Gui-Bo

    2016-05-01

    Various studies showed that entecavir (ETV) failed to improve the short-term survival in chronic hepatitis B (CHB) patients with severe acute exacerbation (SAE) and hepatic de-compensation or acute-on-chronic liver failure (ACLF). One study concluded that plasma exchange (PE) significantly decreased the short-term mortality of CHB patients with ACLF who were treated with lamivudine (LAM). Our study was designed to examine the effect of PE on CHB patients with ACLF who were treated with ETV. From August 2010 to January 2015, 38 (PE group) and 120 (control group) consecutive CHB-naïve patients with hepatic de-compensation and ACLF treated with PE plus ETV and ETV, respectively, were recruited. The primary endpoint was liver-related mortality at week 12. Biochemical and virological responses were also studied. At baseline, the PE group had higher serum alanine aminotransferase (ALT) levels and model for end-stage liver disease (MELD) scores, and had lower albumin levels than the control group. The cumulative survival rate at week 4 and week 12 in the PE group and control group were, respectively, 37 and 18 %, and 29 and 14 % (p  0.05). Univariate analysis showed that the control group had a higher liver-related mortality (p = 0.038) at week 12 than the PE group. Multivariate analysis showed that hepatic encephalopathy, ascites, PE treatment, and MELD scores were independent factors for liver-related mortality at week 12. PE significantly improved the short-term survival of CHB patients with hepatic de-compensation and ACLF who were treated with ETV. Hepatic encephalopathy, ascites, PE treatment, and MELD scores were independent factors for liver-related mortality at week 12.

  10. The influence of 5-HTTLPR genotype on the association between the plasma concentration and therapeutic effect of paroxetine in patients with major depressive disorder.

    Directory of Open Access Journals (Sweden)

    Tetsu Tomita

    Full Text Available The efficacy of treatment with selective serotonin reuptake inhibitors in patients with major depressive disorder (MDD can differ depending on the patient's serotonin transporter-linked polymorphic region (5-HTTLPR genotype, and the effects of varying plasma concentrations of drugs can also vary. We investigated the association between the paroxetine plasma concentration and clinical response in patients with different 5-HTTLPR genotypes.Fifty-one patients were enrolled in this study. The Montgomery-Asberg Depression Rating Scale (MADRS was used to evaluate patients at 0, 1, 2, 4, and 6 weeks. The patients' paroxetine plasma concentrations at week 6 were measured using high-performance liquid chromatography. Additionally, their 5-HTTLPR polymorphisms (alleles S and L were analyzed using a polymerase chain reaction with specific primers. We divided the participants into two groups based on their L haplotype: the SS group and the SL and LL group. We performed single and multiple regression analyses to investigate the associations between MADRS improvement and paroxetine plasma concentrations or other covariates for each group.There were no significant differences between the two groups with regard to demographic or clinical data. In the SS group, the paroxetine plasma concentration was significantly negatively correlated with improvement in MADRS at week 6. In the SL and LL group, the paroxetine plasma concentration was significantly positively correlated with improvement in MADRS at week 6 according to the results of the single regression analysis; however, it was not significantly correlated with improvement in MADRS at week 6 according to the results of the multiple regression analysis.Among patients with MDD who do not respond to paroxetine, a lower plasma concentration or a lower oral dose of paroxetine might be more effective in those with the SS genotype, and a higher plasma concentration might be more effective in those with the SL or LL

  11. Effect of therapeutic concentration of lithium on live HEK293 cells; increase of Na+/K+-ATPase, change of overall protein composition and alteration of surface layer of plasma membrane.

    Science.gov (United States)

    Vosahlikova, Miroslava; Ujcikova, Hana; Chernyavskiy, Oleksandr; Brejchova, Jana; Roubalova, Lenka; Alda, Martin; Svoboda, Petr

    2017-05-01

    The effect of long-term exposure of live cells to lithium cations (Li) was studied in HEK293 cells cultivated in the presence of 1mM LiCl for 7 or 21days. The alteration of Na + /K + -ATPase level, protein composition and biophysical state of plasma membrane was determined with the aim to characterize the physiological state of Li-treated cells. Na + /K + -ATPase level was determined by [ 3 H]ouabain binding and immunoblot assays. Overall protein composition was determined by 2D electrophoresis followed by proteomic analysis by MALDI-TOF MS/MS and LFQ. Li interaction with plasma membrane was characterized by fluorescent probes DPH, TMA-DPH and Laurdan. Na + /K + -ATPase was increased in plasma membranes isolated from cells exposed to Li. Identification of Li-altered proteins by 2D electrophoresis, MALDI-TOF MS/MS and LFQ suggests a change of energy metabolism in mitochondria and cytosol and alteration of cell homeostasis of calcium. Measurement of Laurdan generalized polarization indicated a significant alteration of surface layer of isolated plasma membranes prepared from both types of Li-treated cells. Prolonged exposure of HEK293 cells to 1mM LiCl results in up-regulation of Na + /K + -ATPase expression, reorganization of overall cellular metabolism and alteration of the surface layer/polar head-group region of isolated plasma membranes. Our findings demonstrate adaptation of live HEK293 cell metabolism to prolonged exposure to therapeutic concentration of Li manifested as up-regulation of Na + /K + -ATPase expression, alteration of protein composition and change of the surface layer of plasma membrane. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. An LC-MS Assay with Isocratic Separation and On-Line Solid Phase Extraction to Improve the Routine Therapeutic Drug Monitoring of Busulfan in Plasma

    Directory of Open Access Journals (Sweden)

    Ialongo Cristiano

    2017-04-01

    Full Text Available Background: Busulfan (Bu requires therapeutic drug monitoring (TDM in subjects undergoing a conditioning regimen for hematopoietic stem cell transplantation (HSCT. To speed up the procedure and increase reproducibility, we improved our routine LC-MS/MS assay using the on-line solid-phase extraction (SPE of samples.

  13. The therapeutic collaboration in life design counselling: The case of ...

    African Journals Online (AJOL)

    This study examined the therapeutic collaboration in a case of Life Design ... In globalised societies, job opportunities and employment conditions are fragile and unstable, requiring ..... balance of therapeutic exchanges involving suppor-.

  14. Combination of nitric oxide therapy, anti-oxidative therapy, low level laser therapy, plasma rich platelet therapy and stem cell therapy as a novel therapeutic application to manage the pain and treat many clinical conditions

    Science.gov (United States)

    Halasa, Salaheldin; Dickinson, Eva

    2014-02-01

    From hypertension to diabetes, cancer to HIV, stroke to memory loss and learning disorders to septic shock, male impotence to tuberculosis, there is probably no pathological condition where nitric oxide does not play an important role. Nitric oxide is an analgesic, immune-modulator, vasodilator, anti-apoptotic, growth modulator, angiogenetic, anti-thrombotic, anti-inflammatory and neuro-modulator. Because of the above actions of nitric oxide, many clinical conditions associated with abnormal Nitric oxide (NO) production and bioavailability. Our novel therapeutic approach is to restore the homeostasis of nitric oxide and replace the lost cells by combining nitric oxide therapy, anti-oxidative therapy, low level laser therapy, plasma rich platelet therapy and stem cell therapy.

  15. Macromolecular therapeutics.

    Science.gov (United States)

    Yang, Jiyuan; Kopeček, Jindřich

    2014-09-28

    This review covers water-soluble polymer-drug conjugates and macromolecules that possess biological activity without attached low molecular weight drugs. The main design principles of traditional and backbone degradable polymer-drug conjugates as well as the development of a new paradigm in nanomedicines - (low molecular weight) drug-free macromolecular therapeutics are discussed. To address the biological features of cancer, macromolecular therapeutics directed to stem/progenitor cells and the tumor microenvironment are deliberated. Finally, the future perspectives of the field are briefly debated. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Simultaneous determination of ten antiepileptic drugs in human plasma by liquid chromatography and tandem mass spectrometry with positive/negative ion-switching electrospray ionization and its application in therapeutic drug monitoring.

    Science.gov (United States)

    Yin, Lei; Wang, Tingting; Shi, Meiyun; Zhang, Ying; Zhao, Xiaojun; Yang, Yan; Gu, Jingkai

    2016-03-01

    A simple, rapid, and high-throughput liquid chromatography with tandem mass spectrometry method for the simultaneous quantitation of ten antiepileptic drugs in human plasma has been developed and validated. The method required only 10 μL of plasma. After simple protein precipitation using acetonitrile, the analytes and internal standard diphenhydramine were separated on a Zorbax SB-C18 column (50 × 4.6 mm, 2.7 μm) using acetonitrile/water as the mobile phase at a flow rate of 0.9 mL/min. The total run time was 6 min for each sample. The validation results of specificity, matrix effects, recovery, linearity, precision, and accuracy were satisfactory. The lower limit of quantification was 0.04 μg/mL for carbamazepine, 0.02 μg/mL for lamotrigine, 0.01 μg/mL for oxcarbazepine, 0.4 μg/mL for 10-hydroxycarbazepine, 0.1 μg/mL for carbamazepine-10,11-epoxide, 0.15 μg/mL for levetiracetam, 0.06 μg/mL for phenytoin, 0.3 μg/mL for valproic acid, 0.03 μg/mL for topiramate, and 0.15 μg/mL for phenobarbital. The intraday precision and interday precision were less than 7.6%, with the accuracy ranging between -8.1 and 7.9%. The method was successfully applied to therapeutic drug monitoring of 1237 patients with epilepsy after administration of standard antiepileptic drugs. The method has been proved to meet the high-throughput requirements in therapeutic drug monitoring. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Therapeutic Nanodevices

    Science.gov (United States)

    Lee, Stephen; Ruegsegger, Mark; Barnes, Philip; Smith, Bryan; Ferrari, Mauro

    Therapeutic nanotechnology offers minimally invasive therapies with high densities of function concentrated in small volumes, features that may reduce patient morbidity and mortality. Unlike other areas of nanotechnology, novel physical properties associated with nanoscale dimensionality are not the raison d'être of therapeutic nanotechnology, whereas the aggregation of multiple biochemical (or comparably precise) functions into controlled nanoarchitectures is. Multifunctionality is a hallmark of emerging nanotherapeutic devices, and multifunctionality can allow nanotherapeutic devices to perform multistep work processes, with each functional component contributing to one or more nanodevice subroutine such that, in aggregate, subroutines sum to a cogent work process. Cannonical nanotherapeutic subroutines include tethering (targeting) to sites of disease, dispensing measured doses of drug (or bioactive compound), detection of residual disease after therapy and communication with an external clinician/operator. Emerging nanotherapeutics thus blur the boundaries between medical devices and traditional pharmaceuticals. Assembly of therapeutic nanodevices generally exploits either (bio)material self-assembly properties or chemoselective bioconjugation techniques, or both. Given the complexity, composition, and the necessity for their tight chemical and structural definition inherent in the nature of nanotherapeutics, their cost of goods (COGs) might exceed that of (already expensive) biologics. Early therapeutic nanodevices will likely be applied to disease states which exhibit significant unmet patient need (cancer and cardiovascular disease), while application to other disease states well-served by conventional therapy may await perfection of nanotherapeutic design and assembly protocols.

  18. Effects of anti-aggregant, anti-inflammatory and anti-coagulant drug consumption on the preparation and therapeutic potential of plasma rich in growth factors (PRGF).

    Science.gov (United States)

    Anitua, Eduardo; Troya, María; Zalduendo, Mar; Orive, Gorka

    2015-02-01

    The prevalence and incidence of trauma-related injuries, coronary heart disease and other chronic diseases increase dramatically with age. This population sector is therefore a regular consumer of different types of drugs that may affect platelet aggregation and the coagulation cascade. We have evaluated whether the consumption of acetylsalicylic acid, acenocoumarol, glucosamine sulfate and chondroitin sulfate, and therefore their presence in blood, could interfere with the preparation and biological outcomes of plasma rich in growth factors (PRGF). Clotting time, clot retraction and platelet activation of PRGF was evaluated. PRGF growth factor content and the release of different biomolecules by tendon fibroblasts were also quantified, as well as cell proliferation and cell migration. The preparation and biological potential of PRGF is not affected by the intake of the evaluated drugs, and solely its angiogenic potential and its capacity to induce HA and fibronectin synthesis, is reduced in patients taking anti-coagulants.

  19. Treatment of Alzheimer disease using combination therapy with plasma exchange and haemapheresis with albumin and intravenous immunoglobulin: Rationale and treatment approach of the AMBAR (Alzheimer Management By Albumin Replacement) study.

    Science.gov (United States)

    Boada, M; Ramos-Fernández, E; Guivernau, B; Muñoz, F J; Costa, M; Ortiz, A M; Jorquera, J I; Núñez, L; Torres, M; Páez, A

    2016-09-01

    There is a growing interest in new therapeutic strategies for the treatment of Alzheimer disease (AD) which focus on reducing the beta-amyloid peptide (Aβ) burden in the brain by sequestering plasma Aβ, a large proportion of which is bound to albumin and other proteins. This review discusses the concepts of interaction between Aβ and albumin that have given rise to AMBAR (Alzheimer's Disease Management by Albumin Replacement) project, a new multicentre, randomised, controlled clinical trial for the treatment of AD. Results from preliminary research suggest that Albutein(®) (therapeutic albumin, Grifols) contains no quantifiable levels of Aβ. Studies also show that Albutein(®) has Aβ binding capacity. On the other hand, AD entails a high level of nitro-oxidative stress associated with fibrillar aggregates of Aβ that can induce albumin modification, thus affecting its biological functions. Results from the phase ii study confirm that using therapeutic apheresis to replace endogenous albumin with Albutein(®) 5% is feasible and safe in patients with AD. This process resulted in mobilisation of Aβ and cognitive improvement in treated patients. The AMBAR study will test combination therapy with therapeutic apheresis and haemopheresis with the possible leverage effect of Albutein(®) with intravenous immunoglobulin replacement (Flebogamma(®) DIF). Cognitive, functional, and behavioural changes in patients with mild to moderate AD will be assessed. the AMBAR study represents a new therapeutic perspective for AD. Copyright © 2014 Sociedad Española de Neurología. Publicado por Elsevier España, S.L.U. All rights reserved.

  20. Rapid isolation of plutonium in environmental solid samples using sequential injection anion exchange chromatography followed by detection with inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Qiao Jixin, E-mail: jixin.qiao@risoe.d [Radiation Research Division, Riso National Laboratory for Sustainable Energy, Technical University of Denmark, DK-4000 Roskilde (Denmark); Hou Xiaolin; Roos, Per [Radiation Research Division, Riso National Laboratory for Sustainable Energy, Technical University of Denmark, DK-4000 Roskilde (Denmark); Miro, Manuel [Department of Chemistry, Faculty of Sciences, University of the Balearic Islands, Carretera de Valldemossa km. 7.5, E-07122 Palma de Mallorca, Illes Balears (Spain)

    2011-01-31

    This paper reports an automated analytical method for rapid determination of plutonium isotopes ({sup 239}Pu and {sup 240}Pu) in environmental solid extracts. Anion exchange chromatographic columns were incorporated in a sequential injection (SI) system to undertake the automated separation of plutonium from matrix and interfering elements. The analytical results most distinctly demonstrated that the crosslinkage of the anion exchanger is a key parameter controlling the separation efficiency. AG 1-x4 type resin was selected as the most suitable sorbent material for analyte separation. Investigation of column size effect upon the separation efficiency revealed that small-sized (2 mL) columns sufficed to handle up to 50 g of environmental soil samples. Under the optimum conditions, chemical yields of plutonium exceeded 90% and the decontamination factors for uranium, thorium and lead ranged from 10{sup 3} to 10{sup 4}. The determination of plutonium isotopes in three standard/certified reference materials (IAEA-375 soil, IAEA-135 sediment and NIST-4359 seaweed) and two reference samples (Irish Sea sediment and Danish soil) revealed a good agreement with reference/certified values. The SI column-separation method is straightforward and less labor intensive as compared with batch-wise anion exchange chromatographic procedures. Besides, the automated method features low consumption of ion-exchanger and reagents for column washing and elution, with the consequent decrease in the generation of acidic waste, thus bearing green chemical credentials.

  1. Effect of nebulizer/spray chamber interfaces on simultaneous, axial view inductively coupled plasma optical emission spectrometry for the direct determination of As and Se species separated by ion exchange high-performance liquid chromatography

    International Nuclear Information System (INIS)

    Gettar, Raquel T.; Smichowski, Patricia; Garavaglia, Ricardo N.; Farias, Silvia; Batistoni, Daniel A.

    2005-01-01

    Different nebulizer/expansion chamber combinations were evaluated to assess their performance for sample introduction in the direct coupling with an axial view inductively coupled plasma multielement spectrometer for on-line determination of As and Se species previously separated by ion exchange-high performance liquid chromatography. The column effluents were injected into the plasma without prior derivatization. The instrument operation software was adapted for data acquisition and processing to allow multi-wavelength recording of the transient chromatographic peaks. After optimization of the chromatographic operating conditions, separation of mixtures of inorganic As and Se species, and of inorganic and two organic As species (monomethylarsonic and dimethylarsinic acids), was achieved with excellent resolution. Species discrimination from mixtures of As and Se oxyanions was further improved by the simultaneous element detection at specific analytical wavelengths. Three nebulizers and three spray chambers, employed in seven combinations, were tested as interfaces. Concentric nebulizers associated to a glass cyclonic chamber appear most suitable regarding sensitivity and signal to noise ratio. Measured element detection limits (3 σ) were around 10 ng ml -1 for all the species considered, making the method a viable alternative to similar procedures that employ volatile hydride generation previous to sample injection into the plasma. Analytical recoveries both for inorganic and organic species ranged between 92 and 107%. The method was demonstrated to be apt for the analysis of surface waters potentially subjected to natural contamination with arsenic

  2. Evolution of radiation losses and importance of charge exchange between plasma impurities and injection beam neutrals in the W VII-A stellarator

    International Nuclear Information System (INIS)

    Smeulders, P.

    1981-01-01

    In certain discharges during Neutral Injection (N.I.) (84 0 CO-injection) in the 1 = 2, m = 5 WENDELSTEIN VII-A Stellarator impurity accumulation in the plasma center seems to occur as seen by bolometric, spectroscopic and ultra soft X-ray (USX) measurement. The time evolution of the radiation losses is shown. Three possible sources of the impurities which are responsible for the high central radiation losses are: - Beam injected impurities. - Plasma wall interaction. - Molybdenum protection plates. Possible mechanisms that can be responsible for the central impurity accumulations are: - An inward flow of the plasma or beam impurities. - An increased peaking of the depostion of the beam impurities. Various factors influencing the behaviour of the central radiation are mentioned. (orig./AH)

  3. Clinical screening of paraquat in plasma samples using capillary electrophoresis with contactless conductivity detection: Towards rapid diagnosis and therapeutic treatment of acute paraquat poisoning in Vietnam.

    Science.gov (United States)

    Vu, Anh Phuong; Nguyen, Thi Ngan; Do, Thi Trang; Doan, Thu Ha; Ha, Tran Hung; Ta, Thi Thao; Nguyen, Hung Long; Hauser, Peter C; Nguyen, Thi Anh Huong; Mai, Thanh Duc

    2017-08-15

    The employment of a purpose-made capillary electrophoresis (CE) instrument with capacitively coupled contactless conductivity detection (C 4 D) as a simple and cost-effective solution for clinical screening of paraquat in plasma samples for early-stage diagnosis of acute herbicide poisoning is reported. Paraquat was determined using an electrolyte composed of 10mM histidine adjusted to pH 4 with acetic acid. A detection limit of 0.5mg/L was achieved. Good agreement between results from CE-C 4 D and the confirmation method (HPLC-UV) was obtained, with relative errors for the two pairs of data better than 20% for 31 samples taken from paraquat-intoxicated patients. The results were used by medical doctors for identification and prognosis of acute paraquat poisoning cases. The objective of the work is the deployment of the developed approach in rural areas in Vietnam as a low-cost solution to reduce the mortality rate due to accidental or suicidal ingestion of paraquat. Copyright © 2017. Published by Elsevier B.V.

  4. Plasma homovanillic acid levels and therapeutic outcome in schizophrenics: comparisons of neuroleptic-naive first-episode patients and patients with disease exacerbation due to neuroleptic discontinuance.

    Science.gov (United States)

    Akiyama, K; Tsuchida, K; Kanzaki, A; Ujike, H; Hamamura, T; Kondo, K; Mutoh, S; Miyanagi, K; Kuroda, S; Otsuki, S

    1995-11-15

    Plasma homovanillic acid (pHVA) levels were measured and the Brief Psychiatric Rating Scale (BPRS) scores were evaluated in 26 schizophrenic patients who had either never been medicated (neuroleptic-naive, first-episode subjects) or whose condition had become exacerbated following neuroleptic discontinuance (exacerbated subjects). All the subjects received medication with a fixed dose of a neuroleptic (haloperidol or fluphenazine, both 9 mg/day) for the first week and variable doses for the subsequent 4 weeks. In the neuroleptic-naive subjects, pHVA levels increased significantly 1 week after starting the protocol; this increase correlated significantly with clinical improvement of the BPRS positive symptom scores at week 5. In the neuroleptic-naive subjects, pHVA levels had declined to the baseline level by week 5. In the exacerbated subjects, there were no significant correlations between pHVA level changes at week 1 and later improvements of the BPRS positive symptom scores. These results suggest that the rise in pHVA levels occurring within 1 week after starting a fixed neuroleptic dose may predict a favorable clinical response in neuroleptic-naive schizophrenic patients.

  5. Heat exchanger

    International Nuclear Information System (INIS)

    Dostatni, A.W.; Dostatni, Michel.

    1976-01-01

    In the main patent, a description was given of a heat exchanger with an exchange surface in preformed sheet metal designed for the high pressure and temperature service particularly encountered in nuclear pressurized water reactors and which is characterised by the fact that it is composed of at least one exchanger bundle sealed in a containment, the said bundle or bundles being composed of numerous juxtaposed individual compartments whose exchange faces are built of preformed sheet metal. The present addendun certificate concerns shapes of bundles and their positioning methods in the exchanger containment enabling its compactness to be increased [fr

  6. Therapeutic ultrasound

    International Nuclear Information System (INIS)

    Crum, Lawrence A

    2004-01-01

    The use of ultrasound in medicine is now quite commonplace, especially with the recent introduction of small, portable and relatively inexpensive, hand-held diagnostic imaging devices. Moreover, ultrasound has expanded beyond the imaging realm, with methods and applications extending to novel therapeutic and surgical uses. These applications broadly include: tissue ablation, acoustocautery, lipoplasty, site-specific and ultrasound mediated drug activity, extracorporeal lithotripsy, and the enhancement of natural physiological functions such as wound healing and tissue regeneration. A particularly attractive aspect of this technology is that diagnostic and therapeutic systems can be combined to produce totally non-invasive, imageguided therapy. This general lecture will review a number of these exciting new applications of ultrasound and address some of the basic scientific questions and future challenges in developing these methods and technologies for general use in our society. We shall particularly emphasize the use of High Intensity Focused Ultrasound (HIFU) in the treatment of benign and malignant tumors as well as the introduction of acoustic hemostasis, especially in organs which are difficult to treat using conventional medical and surgical techniques. (amum lecture)

  7. Development of anion-exchange/reversed-phase high performance liquid chromatography-inductively coupled plasma-mass spectrometry methods for the speciation of bio-available iodine and bromine from edible seaweed.

    Science.gov (United States)

    Romarís-Hortas, Vanessa; Bermejo-Barrera, Pilar; Moreda-Piñeiro, Antonio

    2012-05-04

    Anion exchange high performance liquid chromatography hyphenated with inductively coupled plasma-mass spectrometry has been novelly applied to assess inorganic (iodide and iodate) and organic (3-iodotyrosine - MIT, and 3,5-diiodotyrosine - DIT) iodine species in a single chromatographic run. The optimized operating conditions (Dionex IonPac AS7, gradient elution with 175 mM ammonium nitrate plus 15% (v/v) methanol, pH 3.8, as a mobile phase and flow rates within the 0.5-1.5 mL min(-1) range) have also been used to perform inorganic bromine speciation analysis (bromide and bromate). The developed method has been applied for determining the bio-available contents of iodine and bromine species in dialyzates from edible seaweed. Reverse phase high performance liquid chromatography (Zorbax Eclipse XDB-C8, gradient elution with 0.2% (m/m) acetic acid, and 0.2% (m/m) acetic acid in methanol, as mobile phases, and a constant flow rate of 0.75 mL min(-1)) also hyphenated with inductively coupled plasma-mass spectrometry was used to confirm the presence of organic iodine species (MIT and DIT) in the dialyzates. The verification of the presence of iodinated amino acids (MIT and DIT) in the extracts was also performed by reverse phase high performance liquid chromatography-electrospray ionization-mass spectrometry (LTQ Orbitrap). The developed methods have provided good repeatability (RSD values lower than 10% for both anion exchange and reverse phase separations) and analytical recoveries within the 90-105% range for all cases. The in vitro bio-availability method consisted of a simulated gastric and an intestinal digestion/dialysis (10 kDa molecular weight cut-off - MWCO) two-stage procedure. Iodide and MIT were the main bio-available species quantified, whereas bromide was the major bromine species found in the extracts. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. The therapeutic collaboration in life design counselling: The case of ...

    African Journals Online (AJOL)

    The collaboration coding system enables the assessment of each therapeutic exchange within and outside of the client's therapeutic zone of proximal development, defined as the space between the client's actual therapeutic developmental level and his/her potential developmental level fomented by a collaborative ...

  9. Heat exchanger

    International Nuclear Information System (INIS)

    Leigh, D.G.

    1976-01-01

    The arrangement described relates particularly to heat exchangers for use in fast reactor power plants, in which heat is extracted from the reactor core by primary liquid metal coolant and is then transferred to secondary liquid metal coolant by means of intermediate heat exchangers. One of the main requirements of such a system, if used in a pool type fast reactor, is that the pressure drop on the primary coolant side must be kept to a minimum consistent with the maintenance of a limited dynamic head in the pool vessel. The intermediate heat exchanger must also be compact enough to be accommodated in the reactor vessel, and the heat exchanger tubes must be available for inspection and the detection and plugging of leaks. If, however, the heat exchanger is located outside the reactor vessel, as in the case of a loop system reactor, a higher pressure drop on the primary coolant side is acceptable, and space restriction is less severe. An object of the arrangement described is to provide a method of heat exchange and a heat exchanger to meet these problems. A further object is to provide a method that ensures that excessive temperature variations are not imposed on welded tube joints by sudden changes in the primary coolant flow path. Full constructional details are given. (U.K.)

  10. Multijunction Capillary Isoelectric Focusing Device Combined with Online Membrane-Assisted Buffer Exchanger Enables Isoelectric Point Fractionation of Intact Human Plasma Proteins for Biomarker Discovery.

    Science.gov (United States)

    Pirmoradian, Mohammad; Astorga-Wells, Juan; Zubarev, Roman A

    2015-12-01

    Prefractionation of proteins is often employed to improve analysis specificity in proteomics. Prefractionation based on the isoelectric point (pI) is particularly attractive because pI is a well-defined parameter and it is orthogonal to hydrophobicity on which reversed-phase chromatography is based. However, direct capillary electrophoresis of blood proteins is challenging due to its high content of salts and charged small molecules. Here, we couple an online desalinator device to our multijunction capillary isoelectric focusing (MJ-CIEF) instrument and perform direct isoelectric separation of human blood plasma. In a proof-of-principle experiment, pooled samples of patients with progressive mild cognitive impairment and corresponding healthy controls were investigated. Injection of 3 μL of plasma containing over 100 μg of proteins into the desalinator was followed by pI fractionation with MJ-CIEF in less than 1 h. Shotgun proteomics of 12 collected fractions from each of the 5 replicates of pooled samples resulted in the identification and accurate quantification (median CV between the replicates is <4%) of nearly 365 protein groups from 4030 unique peptides (with <1% FDR for both peptides and proteins). The obtained results include several proteins previously reported as AD markers. The isoelectric point of each quantified protein was calculated using a set of 7 synthetic peptides spiked into the samples. Several proteins with a significant pI shift between their isoforms in the patient and control samples were identified. The presented method is straightforward, robust, and scalable; therefore, it can be used in both biological and clinical applications.

  11. Plasma fractionation issues.

    Science.gov (United States)

    Farrugia, Albert; Evers, Theo; Falcou, Pierre-Francois; Burnouf, Thierry; Amorim, Luiz; Thomas, Sylvia

    2009-04-01

    Procurement and processing of human plasma for fractionation of therapeutic proteins or biological medicines used in clinical practice is a multi-billion dollar international trade. Together the private sector and public sector (non-profit) provide large amounts of safe and effective therapeutic plasma proteins needed worldwide. The principal therapeutic proteins produced by the dichotomous industry include gamma globulins or immunoglobulins (including pathogen-specific hyperimmune globulins, such as hepatitis B immune globulins) albumin, factor VIII and Factor IX concentrates. Viral inactivation, principally by solvent detergent and other processes, has proven highly effective in preventing transmission of enveloped viruses, viz. HBV, HIV, and HCV.

  12. Exchange Network

    Science.gov (United States)

    The Environmental Information Exchange Network (EN) is an Internet-based system used by state, tribal and territorial partners to securely share environmental and health information with one another and EPA.

  13. Combined use of bone marrow-derived mesenchymal stromal cells (BM-MSCs) and platelet rich plasma (PRP) stimulates proliferation and differentiation of myoblasts in vitro: new therapeutic perspectives for skeletal muscle repair/regeneration.

    Science.gov (United States)

    Sassoli, Chiara; Vallone, Larissa; Tani, Alessia; Chellini, Flaminia; Nosi, Daniele; Zecchi-Orlandini, Sandra

    2018-02-05

    Satellite cell-mediated skeletal muscle repair/regeneration is compromised in cases of extended damage. Bone marrow mesenchymal stromal cells (BM-MSCs) hold promise for muscle healing but some criticisms hamper their clinical application, including the need to avoid animal serum contamination for expansion and the scarce survival after transplant. In this context, platelet-rich plasma (PRP) could offer advantages. Here, we compare the effects of PRP or standard culture media on C2C12 myoblast, satellite cell and BM-MSC viability, survival, proliferation and myogenic differentiation and evaluate PRP/BM-MSC combination effects in promoting myogenic differentiation. PRP induced an increase of mitochondrial activity and Ki67 expression comparable or even greater than that elicited by standard media and promoted AKT signaling activation in myoblasts and BM-MSCs and Notch-1 pathway activation in BM-MSCs. It stimulated MyoD, myogenin, α-sarcomeric actin and MMP-2 expression in myoblasts and satellite cell activation. Notably, PRP/BM-MSC combination was more effective than PRP alone. We found that BM-MSCs influenced myoblast responses through a paracrine activation of AKT signaling, contributing to shed light on BM-MSC action mechanisms. Our results suggest that PRP represents a good serum substitute for BM-MSC manipulation in vitro and could be beneficial towards transplanted cells in vivo. Moreover, it might influence muscle resident progenitors' fate, thus favoring the endogenous repair/regeneration mechanisms. Finally, within the limitations of an in vitro experimentation, this study provides an experimental background for considering the PRP/BM-MSC combination as a potential therapeutic tool for skeletal muscle damage, combining the beneficial effects of BM-MSCs and PRP on muscle tissue, while potentiating BM-MSC functionality.

  14. Sm isotope composition and Sm/Eu ratio determination in an irradiated 153Eu sample by ion exchange chromatography-quadrupole inductively coupled plasma mass spectrometry combined with double spike isotope dilution technique

    International Nuclear Information System (INIS)

    Bourgeois, M.; Isnard, H.; Gourgiotis, A.; Stadelmann, G.; Gautier, C.; Mialle, S.; Nonell, A.; Chartier, F.

    2011-01-01

    Within the framework of the research undertaken by the French Atomic Energy Commission on transmutation of long-lived radionuclides, targets of highly enriched actinides and fission products were irradiated in the fast neutron reactor Phenix. Precise and accurate measurements of the isotopic and elemental composition of the enriched elements are therefore required. In order to obtain the uncertainties of several per mil and to reduce handling time and exposure to analyst on radioactive material, the on-line coupling of ion exchange chromatography with quadrupole inductively coupled plasma mass spectrometry has been associated with the technique of the double spike isotope dilution. We present in this paper the results obtained on an irradiated sample of Europium oxide powder (enriched at 99.13% in 153 Eu). After irradiation of around 5 mg of Eu 2 O 3 powder the theoretical calculations predict the formation of several micrograms of gadolinium and samarium isotopes. In relation to the very high activity of the sample after irradiation and the very low quantity of Sm formed, the on-line ion exchange chromatography separation of Gd, Sm and Eu before Sm isotope ratio measurements has been developed for the quantification of the 152 Sm/ 153 Eu ratio. These on-line measurements were associated with the double spike isotope dilution technique after calibration of a 147 Sm/ 151 Eu spike solution. The external reproducibility of Sm isotopic ratios was determined to be around 0.5% (2 σ) resulting in a final uncertainty on the 152 Sm/ 153 Eu ratio of around 1% (2 σ). These on-line measurements present therefore a robust and high-throughput alternative to the thermal-ionisation mass spectrometry technique used so far in combination with off-line chromatographic separation, particularly in nuclear applications where characterisation of high activity sample solutions is required. (authors)

  15. A new nebulization device with exchangeable aerosol generation mode as a useful tool to investigate sample introduction processes in inductively coupled plasma atomic emission spectrometry

    International Nuclear Information System (INIS)

    Grotti, Marco; Lagomarsino, Cristina; Frache, Roberto

    2004-01-01

    A new sample introduction device has been designed in order to differentiate between the effects of the aerosol production and its following desolvation on analytical performances of an inductively coupled plasma optical spectrometer. This research tool allows to easily switch between the pneumatic and ultrasonic aerosol generation mode and to use a joint desolvation chamber. In this way, a real comparison between aerosol production systems may be attained and the influence of aerosol generation process on analytical figures clearly distinguished from that of the desolvation process. In this work, the separate effects of the aerosol generation and desolvation processes on analytical sensitivity and tolerance towards matrix effects have been investigated. Concerning sensitivity, it was found that both the processes play an important role in determining emission intensities, being the increase in sensitivity due to desolvation higher than that due to the improved aerosol generation efficiency. Concerning the matrix effects, a predominant role of the desolvation system was found, while the influence of the aerosol generation mode was much less important. For nitric acid, the decreasing effect was mitigated by the presence of a desolvation system, due to partial removal of the acid. On the contrary, the depressive effect of sulfuric acid was enhanced by the presence of a desolvation system, due to degradation of the solvent removal efficiency and to further decrease in the analyte transport rate caused by clustering phenomena. Concerning the interferences due to sodium and calcium, a depressive effect was observed, which is enhanced by desolvation

  16. Exchangers man the pumps

    Science.gov (United States)

    Barkla, Bronwyn J; Hirschi, Kendal D

    2008-01-01

    Tonoplast-localised proton-coupled Ca2+ transporters encoded by cation/H+ exchanger (CAX) genes play a critical role in sequestering Ca2+ into the vacuole. These transporters may function in coordination with Ca2+ release channels, to shape stimulus-induced cytosolic Ca2+ elevations. Recent analysis of Arabidopsis CAX knockout mutants, particularly cax1 and cax3, identified a variety of phenotypes including sensitivity to abiotic stresses, which indicated that these transporters might play a role in mediating the plant's stress response. A common feature of these mutants was the perturbation of H+-ATPase activity at both the tonoplast and the plasma membrane, suggesting a tight interplay between the Ca2+/H+ exchangers and H+ pumps. We speculate that indirect regulation of proton flux by the exchangers may be as important as the direct regulation of Ca2+ flux. These results suggest cautious interpretation of mutant Ca2+/H+ exchanger phenotypes that may be due to either perturbed Ca2+ or H+ transport. PMID:19841670

  17. Accurate determination of trace amounts of phosphorus in geological samples by inductively coupled plasma atomic emission spectrometry with ion-exchange separation

    International Nuclear Information System (INIS)

    Asoh, Kazuya; Ebihara, Mitsuru

    2013-01-01

    Graphical abstract: -- Highlights: •We set up an effective ICP-AES procedure for determining trace P in rock samples. •Some certified values of P for reference rock samples were proved to be doubtful. •Accurate and reliable data were presented for a suite of geological reference rocks. -- Abstract: In order to determine trace amounts of phosphorus in geological and cosmochemical rock samples, simple as well as reliable analytical schemes using an ICP-AES instrument were investigated. A (conventional) ICP-AES procedure could determine phosphorus contents at the level of several 100 μg g −1 with a reasonable reproducibility ( −1 ; 1σ). An ICP-AES procedure coupled with matrix-separation using cation and anion exchange resins could lower the quantification level down to 1 μg g −1 or even lower under the present experimental conditions. The matrix-separation ICP-AES procedure developed in this study was applied to twenty-one geological reference samples issued by Geological Survey of Japan. Obtained values vary from 1250 μg g −1 for JB-3 (basalt) to 2.07 μg g −1 for JCt-1 (carbonate). Matrix-separation ICP-AES yielded reasonable reproducibility (less than 8.3%; 1σ) of three replicate analyses for all the samples analyzed. In comparison of our data with certificate values as well as literature or reported values, there appear to be an apparent (and large) discrepancy between our values and certificate/reported values regardless of phosphorus contents. Based on the reproducibility of our data and the analytical capability of the matrix-separation ICP-AES procedure developed in this study (in terms of quantification limit, recovery, selectivity of an analyte through pre-concentration process, etc.), it is concluded that certified values for several reference standard rocks should be reevaluated and revised accordingly. It may be further pointed that some phosphorus data reported in literatures should be critically evaluated when they are to be

  18. Hydrogen exchange

    DEFF Research Database (Denmark)

    Jensen, Pernille Foged; Rand, Kasper Dyrberg

    2016-01-01

    Hydrogen exchange (HX) monitored by mass spectrometry (MS) is a powerful analytical method for investigation of protein conformation and dynamics. HX-MS monitors isotopic exchange of hydrogen in protein backbone amides and thus serves as a sensitive method for probing protein conformation...... and dynamics along the entire protein backbone. This chapter describes the exchange of backbone amide hydrogen which is highly quenchable as it is strongly dependent on the pH and temperature. The HX rates of backbone amide hydrogen are sensitive and very useful probes of protein conformation......, as they are distributed along the polypeptide backbone and form the fundamental hydrogen-bonding networks of basic secondary structure. The effect of pressure on HX in unstructured polypeptides (poly-dl-lysine and oxidatively unfolded ribonuclease A) and native folded proteins (lysozyme and ribonuclease A) was evaluated...

  19. Heat exchanger

    International Nuclear Information System (INIS)

    Drury, C.R.

    1988-01-01

    A heat exchanger having primary and secondary conduits in heat-exchanging relationship is described comprising: at least one serpentine tube having parallel sections connected by reverse bends, the serpentine tube constituting one of the conduits; a group of open-ended tubes disposed adjacent to the parallel sections, the open-ended tubes constituting the other of the conduits, and forming a continuous mass of contacting tubes extending between and surrounding the serpentine tube sections; and means securing the mass of tubes together to form a predetermined cross-section of the entirety of the mass of open-ended tubes and tube sections

  20. A simple method using on-line continuous leaching and ion exchange chromatography coupled to inductively coupled plasma mass spectrometry for the speciation analysis of bio-accessible arsenic in rice.

    Science.gov (United States)

    Horner, Nolan S; Beauchemin, Diane

    2012-03-02

    A simple method for the speciation analysis of bio-accessible arsenic (As) in rice was developed using a continuous on-line leaching method to release the bio-accessible fraction. The continuous on-line leaching method has several advantages over commonly used batch methods including quicker and easier sample preparation, reduced risk of contamination and access to real time leaching data. The bio-accessibility of As in the samples was monitored using inductively coupled plasma mass spectrometry (ICP-MS). Results from a certified reference material as well as cooked and uncooked white rice showed that the majority of As was leached by saliva. Results obtained using the continuous on-line leaching method were comparable to those obtained using a batch method. Speciation analysis of the saliva leachate was performed using ion exchange chromatography coupled to ICP-MS. The four most toxic forms of As (As(III), monomethylarsonic acid (MMA), dimethylarsinic acid (DMA) and As(V)) were clearly separated within 5 min in a single chromatographic run. Over 92% of bio-accessible As in the certified reference material and uncooked white rice sample was in the form of DMA and As(V), whereas it was present as DMA and As(III) in the cooked white rice. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. Heat exchanger

    Science.gov (United States)

    Wolowodiuk, Walter

    1976-01-06

    A heat exchanger of the straight tube type in which different rates of thermal expansion between the straight tubes and the supply pipes furnishing fluid to those tubes do not result in tube failures. The supply pipes each contain a section which is of helical configuration.

  2. Heat exchangers

    International Nuclear Information System (INIS)

    1975-01-01

    The tubes of a heat exchanger tube bank have a portion thereof formed in the shape of a helix, of effective radius equal to the tube radius and the space between two adjacent tubes, to tangentially contact the straight sections of the tubes immediately adjacent thereto and thereby provide support, maintain the spacing and account for differential thermal expansion thereof

  3. Exchange Options

    NARCIS (Netherlands)

    Jamshidian, F.

    2007-01-01

    The contract is described and market examples given. Essential theoretical developments are introduced and cited chronologically. The principles and techniques of hedging and unique pricing are illustrated for the two simplest nontrivial examples: the classical Black-Scholes/Merton/Margrabe exchange

  4. Exchange rates.

    Science.gov (United States)

    Mills, Bev

    2003-09-01

    IN MAY this year, I was lucky enough to go to Larissa in northern Greece as part of Hope Exchange 2003, an annual study tour organised by the European Union's hospital committee and administered by the Institute of Healthcare Management (IHM).

  5. Heat exchanger

    Science.gov (United States)

    Daman, Ernest L.; McCallister, Robert A.

    1979-01-01

    A heat exchanger is provided having first and second fluid chambers for passing primary and secondary fluids. The chambers are spaced apart and have heat pipes extending from inside one chamber to inside the other chamber. A third chamber is provided for passing a purge fluid, and the heat pipe portion between the first and second chambers lies within the third chamber.

  6. Heat exchanger

    International Nuclear Information System (INIS)

    Wolowodiuk, W.

    1976-01-01

    A heat exchanger of the straight tube type is described in which different rates of thermal expansion between the straight tubes and the supply pipes furnishing fluid to those tubes do not result in tube failures. The supply pipes each contain a section which is of helical configuration

  7. Experimental study on the influence of charge exchange on the stopping power in the interaction of chlorine with a gas and a deuterium plasma; Etude experimentale de l`influence des echanges de charges sur le pouvoir d`arret dans l`interaction d`ions chlore avec un gaz et un plasma de deuterium

    Energy Technology Data Exchange (ETDEWEB)

    Nectoux, Marie [Inst. de Physique Nucleaire, Paris-11 Univ., 91 - Orsay (France)

    1998-01-06

    This thesis is placed in the context of the physics of energy deposition of a multicharged heavy ion beam in matter at intermediate energies. The experiment gave measurements of energy loss as a function of final charge state for chlorine ions at 1.7 MeV/u in deuterium gas or plasma. In this way, we explore the influence of charge state evolution, depending on experimentally measured capture and ionization cross sections and the electron density of the target, on energy loss. The target is cylindrical and enclosed by two fast valves. The plasma is created in the gas by a discharge, which induces a magnetic perturbation of the beam (lens effect). This effect induces a divergent and misaligned outgoing beam. A simulation including charge state and velocity evolution of the projectile in flight in the magnetic field has been made in order to optimize beam analysis, to reach a precision better than 10{sup -3} in energy measurement. This study led to removal of the target to the `Split Pole`, a refocusing magnetic spectrometer. The first results obtained clearly show the dependence of energy loss on exit charge and especially on its evolution in the target. This is explained in terms of the lengths covered by the projectile in its successive charge states in the target, which depends on target electron density and the medium considered. In plasma, we observed an energy distribution with exit charge twice that observed in gas, because of a strong decrease of charge exchange. A comparison of data obtained in gas with stopping power calculated from Bethe-Bloch-Barkas theory leads to the necessity of including spatial extension of the projectile charge in the theory. (author) 81 refs., 62 figs., 5tabs.

  8. Ion exchange equilibrium constants

    CERN Document Server

    Marcus, Y

    2013-01-01

    Ion Exchange Equilibrium Constants focuses on the test-compilation of equilibrium constants for ion exchange reactions. The book first underscores the scope of the compilation, equilibrium constants, symbols used, and arrangement of the table. The manuscript then presents the table of equilibrium constants, including polystyrene sulfonate cation exchanger, polyacrylate cation exchanger, polymethacrylate cation exchanger, polysterene phosphate cation exchanger, and zirconium phosphate cation exchanger. The text highlights zirconium oxide anion exchanger, zeolite type 13Y cation exchanger, and

  9. Heat exchanger

    International Nuclear Information System (INIS)

    Bennett, J.C.

    1975-01-01

    A heat exchanger such as forms, for example, part of a power steam boiler is made up of a number of tubes that may be arranged in many different ways, and it is necessary that the tubes be properly supported. The means by which the tubes are secured must be as simple as possible so as to facilitate construction and must be able to continue to function effectively under the varying operating conditions to which the heat exchanger is subject. The arrangement described is designed to meet these requirements, in an improved way. The tubes are secured to a member extending past several tubes and abutment means are provided. At least some of the abutment means comprise two abutment pieces and a wedge secured to the supporting member, that acts on these pieces to maintain the engagement. (U.K.)

  10. Púrpura trombocitopênica trombótica - remissão completa em paciente com mau prognóstico após tratamento com plasmaférese terapêutica e rituximabe Successful outcome in poor-prognostic acute thrombotic thrombocytopenic purpura treated with plasma exchange and rituximab

    Directory of Open Access Journals (Sweden)

    Cesar de Almeida Neto

    2008-02-01

    Full Text Available A púrpura trombocitopênica trombótica (PTT é uma doença rara e fatal que deve ser diagnosticada e tratada prontamente a fim de se obter melhor resposta terapêutica. Apresentamos um caso de PTT aguda grave tratada com plasmaférese e rituximabe. Ao diagnóstico, a paciente apresentava anemia hemolítica microangiopática, icterícia, febre, convulsões, seguidas por coma e choque hipovolêmico. Os exames laboratoriais iniciais mostravam DHL=2.860 IU/L, contagem de plaquetas de 37 x 10(9/L, hemoglobina de 5,1 g/dL e no esfregaço de sangue periférico havia a presença de esquizócitos. Iniciado tratamento para PTT com pulsoterapia com metilprednisolona e plasmaféreses terapêuticas diárias com troca de uma volemia plasmática e substituição com plasma fresco congelado. Após cinco sessões de plasmaférese, houve piora no quadro neurológico, acompanhado por aumento importante de DHL, ALT, AST e a contagem de plaquetas era de 72 x 10(9/L. Iniciamos o uso de rituximabe na dose padrão de 375mg/m²/semana/4 semanas e passamos a utilizar plasma pobre em crioprecipitado como reposição durante as plasmaféreses. Dois dias após a mudança na conduta terapêutica, houve importante melhora do quadro neurológico, estabilização da contagem de plaquetas e queda acentuada de DHL. Após 23 procedimentos de plasmaférese e quatro doses de rituximabe, a paciente apresentou remissão completa, mantida há 34 meses. A plasmaférese terapêutica com plasma pobre em crioprecipitado e o uso concomitante de rituximabe foi uma estratégia útil no tratamento deste caso de PTT aguda grave. Porém, ensaios clínicos prospectivos e randomizados são necessários para confirmar estes achados.Thrombotic thrombocytopenic purpura (TTP is a rare severe disease that must be diagnosed and treated promptly for a successful outcome. We report a case of severe acute TTP treated with plasma exchange and rituximab. The patient presented at diagnosis with severe

  11. Heat exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, E L; Eisenmann, G; Hahne, E [Stuttgart Univ. (TH) (F.R. Germany). Inst. fuer Thermodynamik und Waermetechnik

    1976-04-01

    A survey is presented on publications on design, heat transfer, form factors, free convection, evaporation processes, cooling towers, condensation, annular gap, cross-flowed cylinders, axial flow through a bundle of tubes, roughnesses, convective heat transfer, loss of pressure, radiative heat transfer, finned surfaces, spiral heat exchangers, curved pipes, regeneraters, heat pipes, heat carriers, scaling, heat recovery systems, materials selection, strength calculation, control, instabilities, automation of circuits, operational problems and optimization.

  12. A new ultrafast and high-throughput mass spectrometric approach for the therapeutic drug monitoring of the multi-targeted anti-folate pemetrexed in plasma from lung cancer patients

    NARCIS (Netherlands)

    R.J.W. Meesters (Roland); R. Cornelissen (Robin); R.J. van Klaveren (Rob); R. de Jonge (Robert); E. den Boer (Ethan); J. Lindemans (Jan); T.M. Luider (Theo)

    2010-01-01

    textabstractAn analytical assay has been developed and validated for ultrafast and high-throughput mass spectrometric determination of pemetrexed concentrations in plasma using matrix assisted laser desorption/ionization-triple quadrupole-tandem mass spectrometry. Patient plasma samples spiked with

  13. Plasmas for medicine

    Science.gov (United States)

    von Woedtke, Th.; Reuter, S.; Masur, K.; Weltmann, K.-D.

    2013-09-01

    Plasma medicine is an innovative and emerging field combining plasma physics, life science and clinical medicine. In a more general perspective, medical application of physical plasma can be subdivided into two principal approaches. (i) “Indirect” use of plasma-based or plasma-supplemented techniques to treat surfaces, materials or devices to realize specific qualities for subsequent special medical applications, and (ii) application of physical plasma on or in the human (or animal) body to realize therapeutic effects based on direct interaction of plasma with living tissue. The field of plasma applications for the treatment of medical materials or devices is intensively researched and partially well established for several years. However, plasma medicine in the sense of its actual definition as a new field of research focuses on the use of plasma technology in the treatment of living cells, tissues, and organs. Therefore, the aim of the new research field of plasma medicine is the exploitation of a much more differentiated interaction of specific plasma components with specific structural as well as functional elements or functionalities of living cells. This interaction can possibly lead either to stimulation or inhibition of cellular function and be finally used for therapeutic purposes. During recent years a broad spectrum of different plasma sources with various names dedicated for biomedical applications has been reported. So far, research activities were mainly focused on barrier discharges and plasma jets working at atmospheric pressure. Most efforts to realize plasma application directly on or in the human (or animal) body for medical purposes is concentrated on the broad field of dermatology including wound healing, but also includes cancer treatment, endoscopy, or dentistry. Despite the fact that the field of plasma medicine is very young and until now mostly in an empirical stage of development yet, there are first indicators of its enormous

  14. Optimization of collision/reaction gases for determination of 90Sr in atmospheric particulate matter by inductively coupled plasma tandem mass spectrometry after direct introduction of air via a gas-exchange device

    Science.gov (United States)

    Suzuki, Yoshinari; Ohara, Ryota; Matsunaga, Kirara

    2017-09-01

    Nuclear power plant accidents release radioactive strontium 90 (90Sr) into the environment. Monitoring of 90Sr, although important, is difficult and time consuming because it emits only beta radiation. We have developed a new analytical system that enables real-time analysis of 90Sr in atmospheric particulate matter with an analytical run time of only 10 min. Briefly, after passage of an air sample through an impactor, a small fraction of the sample is introduced into a gas-exchange device, where the air is replaced by Ar. Then the sample is directly introduced into an inductively coupled plasma tandem mass spectrometry (ICP-MS/MS) system equipped with a collision/reaction cell to eliminate isobaric interferences on 90Sr from 90Zr+, 89Y1H+, and 90Y+. Experiments with various reaction gas conditions revealed that these interferences could be minimized under the following optimized conditions: 1.0 mL min- 1 O2, 10.0 mL min- 1 H2, and 1.0 mL min- 1 NH3. The estimated background equivalent concentration and estimated detection limit of the system were 9.7 × 10- 4 and 3.6 × 10- 4 ng m- 3, respectively, which are equivalent to 4.9 × 10- 6 and 1.8 × 10- 6 Bq cm- 3. Recoveries of Sr in PM2.5 measured by real-time analysis compared to those obtained by simultaneously collection on filter was 53 ± 23%, and using this recovery, the detection limit as PM2.5 was estimated to be 3.4 ± 1.5 × 10- 6 Bq cm- 3. That is, this system enabled detection of 90Sr at concentrations < 5 × 10- 6 Bq cm- 3 even considering the insufficient fusion/vaporization/ionization efficiency of Sr in PM2.5.

  15. Exchanging information

    International Nuclear Information System (INIS)

    1971-01-01

    The Agency has a statutory mandate to foster 'the exchange of scientific and technical information on the peaceful uses of atomic energy'. The prime responsibility for this work within the Agency lies with the Division of Scientific and Technical Information, a part of the Department of Technical Operations. The Division accomplishes its task by holding conferences and symposia (Scientific Conferences Section), through the Agency Library, by publishing scientific journals, and through the International Nuclear Information System (INIS). The Computer Section of the Division, which offers services to the Agency as a whole, provides resources for the automation of data storage and retrieval. (author)

  16. Ambipolar diffusion in plasma

    International Nuclear Information System (INIS)

    Silva, T.L. da.

    1987-01-01

    Is this thesis, a numerical method for the solution of the linear diffusion equation for a plasma containing two types of ions, with the possibility of charge exchange, has been developed. It has been shown that the decay time of the electron and ion densities is much smaller than that in a plasma containing only a single type of ion. A non-linear diffusion equation, which includes the effects of an external electric field varying linearly in time, to describe a slightly ionized plasma has also been developed. It has been verified that the decay of the electron density in the presence of such an electric field is very slow. (author)

  17. Matchmaker Exchange.

    Science.gov (United States)

    Sobreira, Nara L M; Arachchi, Harindra; Buske, Orion J; Chong, Jessica X; Hutton, Ben; Foreman, Julia; Schiettecatte, François; Groza, Tudor; Jacobsen, Julius O B; Haendel, Melissa A; Boycott, Kym M; Hamosh, Ada; Rehm, Heidi L

    2017-10-18

    In well over half of the individuals with rare disease who undergo clinical or research next-generation sequencing, the responsible gene cannot be determined. Some reasons for this relatively low yield include unappreciated phenotypic heterogeneity; locus heterogeneity; somatic and germline mosaicism; variants of uncertain functional significance; technically inaccessible areas of the genome; incorrect mode of inheritance investigated; and inadequate communication between clinicians and basic scientists with knowledge of particular genes, proteins, or biological systems. To facilitate such communication and improve the search for patients or model organisms with similar phenotypes and variants in specific candidate genes, we have developed the Matchmaker Exchange (MME). MME was created to establish a federated network connecting databases of genomic and phenotypic data using a common application programming interface (API). To date, seven databases can exchange data using the API (GeneMatcher, PhenomeCentral, DECIPHER, MyGene2, matchbox, Australian Genomics Health Alliance Patient Archive, and Monarch Initiative; the latter included for model organism matching). This article guides usage of the MME for rare disease gene discovery. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 John Wiley and Sons, Inc.

  18. Heat exchanger

    Energy Technology Data Exchange (ETDEWEB)

    Harada, F; Yanagida, T; Fujie, K; Futawatari, H

    1975-04-30

    The purpose of this construction is the improvement of heat transfer in finned tube heat exchangers, and therefore the improvement of its efficiency or its output per unit volume. This is achieved by preventing the formation of flow boundary layers in gaseous fluid. This effect always occurs on flow of smooth adjacent laminae, and especially if these have pipes carrying liquid passing through them; it worsens the heat transfer of such a boundary layer considerably compared to that in the turbulent range. The fins, which have several rows of heat exchange tubes passing through them, are fixed at a small spacing on theses tubes. The fins have slots cut in them by pressing or punching, where the pressed-out material remains as a web, which runs parallel to the level of the fin and at a small distance from it. These webs and slots are arranged radially around every tube hole, e.g. 6 in number. For a suitable small tube spacing, two adjacent tubes opposite each other have one common slot. Many variants of such slot arrangements are illustrated.

  19. Effectiveness of a real-time clinical decision support system for computerized physician order entry of plasma orders.

    Science.gov (United States)

    Yazer, Mark H; Triulzi, Darrell J; Reddy, Vivek; Waters, Jonathan H

    2013-12-01

    We investigated the effect of implementing adaptive plasma ordering criteria in the computerized physician order entry (CPOE) system, with alerts that were automatically generated if the recipient's antecedent international normalized ratio (INR) did not meet the institutional criteria. In a regional health care system consisting of 11 hospitals using a common CPOE, data on the number of plasma orders and alerts that were generated were collected over a 4-month period before prescribers were required to select an indication for plasma. When adaptive ordering was implemented prescribers had to choose from prepopulated indications for plasma: INR of 1.6 or greater with bleeding, INR of 1.6 or greater before an invasive procedure, therapeutic exchange, massive transfusion, and other. Regardless of the antecedent INR the alert did not trigger if massive transfusion or plasmapheresis was selected. Information on prescribers and recipients was collected during this 5-month period. In the 4-month period before the adaptive alerts were implemented, 42.9% of the plasma orders generated an alert; in the 5-month period thereafter the alert rate was significantly lower at 27.9% (p plasma orders were for periprocedure or bleeding patients whose antecedent INR was less than 1.6. There were significant differences in prescriber specialties among those who ordered plasma using the other indication compared to all plasma orders. Electronic interventions improve compliance with plasma guidelines but as implemented are not sufficient to completely curtail non-evidence-based ordering. © 2013 American Association of Blood Banks.

  20. Therapeutic drug monitoring of lopinavir/ritonavir in pregnancy.

    LENUS (Irish Health Repository)

    Lambert, J S

    2011-03-01

    The aim of the study was to determine total and unbound lopinavir (LPV) plasma concentrations in HIV-infected pregnant women receiving lopinavir\\/ritonavir (LPV\\/r tablet) undergoing therapeutic drug monitoring (TDM) during pregnancy and postpartum.

  1. Segmented heat exchanger

    Science.gov (United States)

    Baldwin, Darryl Dean; Willi, Martin Leo; Fiveland, Scott Byron; Timmons, Kristine Ann

    2010-12-14

    A segmented heat exchanger system for transferring heat energy from an exhaust fluid to a working fluid. The heat exchanger system may include a first heat exchanger for receiving incoming working fluid and the exhaust fluid. The working fluid and exhaust fluid may travel through at least a portion of the first heat exchanger in a parallel flow configuration. In addition, the heat exchanger system may include a second heat exchanger for receiving working fluid from the first heat exchanger and exhaust fluid from a third heat exchanger. The working fluid and exhaust fluid may travel through at least a portion of the second heat exchanger in a counter flow configuration. Furthermore, the heat exchanger system may include a third heat exchanger for receiving working fluid from the second heat exchanger and exhaust fluid from the first heat exchanger. The working fluid and exhaust fluid may travel through at least a portion of the third heat exchanger in a parallel flow configuration.

  2. Jeans instability with exchange effects in quantum dusty magnetoplasmas

    International Nuclear Information System (INIS)

    Jamil, M.; Rasheed, A.; Rozina, Ch.; Jung, Y.-D.; Salimullah, M.

    2015-01-01

    Jeans instability is examined in magnetized quantum dusty plasmas using the quantum hydrodynamic model. The quantum effects are considered via exchange-correlation potential, recoil effect, and Fermi degenerate pressure, in addition to thermal effects of plasma species. It is found that the electron exchange and correlation potential have significant effects over the threshold value of wave vector and Jeans instability. The presence of electron exchange and correlation effect shortens the time of dust sound that comparatively stabilizes the self gravitational collapse. The results at quantum scale are helpful in understanding the collapse of the self-gravitating dusty plasma systems

  3. The Balescu kinetic equation with exchange interaction

    International Nuclear Information System (INIS)

    Belyi, V V; Kukharenko, Yu A

    2009-01-01

    Starting with the quantum BBGKY hierarchy for the distribution functions, we have obtained the quantum kinetic equation including the dynamical screening of the interaction potential, which exactly takes into account the exchange scattering in the plasma. The collision integral is expressed in terms of the Green function of the linearized Hartree–Fock equation. The potential energy takes into account the polarization and exchange interaction too

  4. Diagnostic and therapeutic peroral cholangioscopy

    Directory of Open Access Journals (Sweden)

    Jong Ho Moon

    2012-01-01

    Full Text Available Peroral cholangioscopy (POC provides direct visualization of the bile duct and facilitates diagnostic or therapeutic intervention. The currently available single-operator POC systems are "Mother-baby" scope system, SpyGlass direct visualization system, and direct POC using a regular ultra-slim upper endoscope. Direct POC using an ultra-slim upper endoscope having a larger 2-mm working channel can provide a valuable and economic solution for evaluating bile-duct lesions. Main diagnostic procedures under direct POC are visual characterization and optically guided target biopsy for the indeterminate bile duct lesion. Image-enhanced endoscopy such as narrow-band imaging has shown promise for more detailed evaluation of mucosal abnormality and can be performed under direct POC. Intracorporeal lithotripsy such as electrohydraulic lithotripsy or laser lithotripsy is a main therapeutic intervention of direct POC for patients with bile duct stones that are resistant to conventional endoscopic stone-removal procedures. Besides, tumor ablation therapy, such as photodynamic therapy and argon plasma coagulation may be also performed using direct POC. Further developments of the endoscope and specialized accessories or devices are expected to facilitate diagnostic and therapeutic role of this cholangioscopic procedure.

  5. Tokamak rotation and charge exchange

    International Nuclear Information System (INIS)

    Hazeltine, R.D.; Rowan, W.L.; Solano, E.R.; Valanju, P.M.

    1991-01-01

    In the absence of momentum input, tokamak toroidal rotation rates are typically small - no larger in particular than poloidal rotation - even when the radial electric field is strong, as near the plasma edge. This circumstance, contradicting conventional neoclassical theory, is commonly attributed to the rotation damping effect of charge exchange, although a detailed comparison between charge-exchange damping theory and experiment is apparently unavailable. Such a comparison is attempted here in the context of recent TEXT experiments, which compare rotation rates, both poloidal and toroidal, in helium and hydrogen discharges. The helium discharges provide useful data because they are nearly free of ion-neutral charge exchange; they have been found to rotate toroidally in reasonable agreement with neoclassical predictions. The hydrogen experiments show much smaller toroidal motion as usual. The theoretical calculation uses the full charge-exchange operator and assumes plateau collisionality, roughly consistent with the experimental conditions. The authors calculate the ion flow as a function of v cx /v c , where v cx is the charge exchange rate and v c the Coulomb collision frequency. The results are in reasonable accord with the observations. 1 ref

  6. Therapeutic drug monitoring of atazanavir/ritonavir in pregnancy.

    LENUS (Irish Health Repository)

    Else, L J

    2014-11-01

    Pregnant women experience physiological changes during pregnancy that can have a significant impact on antiretroviral pharmacokinetics. Ensuring optimal plasma concentrations of antiretrovirals is essential for maternal health and to minimize the risk of vertical transmission. Here we describe atazanavir\\/ritonavir (ATV\\/r) plasma concentrations in a cohort of pregnant women undergoing routine therapeutic drug monitoring (TDM).

  7. Investigating the Interaction between the Neonatal Fc Receptor and Monoclonal Antibody Variants by Hydrogen/Deuterium Exchange Mass Spectrometry

    DEFF Research Database (Denmark)

    Jensen, Pernille Foged; Larraillet, Vincent; Schlothauer, Tilman

    2015-01-01

    The recycling of immunoglobulins by the neonatal Fc receptor (FcRn) is of crucial importance in the maintenance of antibody levels in plasma and is responsible for the long half-lives of endogenous and recombinant monoclonal antibodies. From a therapeutic point of view there is great interest...... in understanding and modulating the IgG-FcRn interaction to optimize antibody pharmacokinetics and ultimately improve efficacy and safety. Here we studied the interaction between a full-length human IgG1 and human FcRn via hydrogen/deuterium exchange mass spectrometry and targeted electron transfer dissociation...... to map sites perturbed by binding on both partners of the IgG-FcRn complex. Several regions in the antibody Fc region and the FcRn were protected from exchange upon complex formation, in good agreement with previous crystallographic studies of FcRn in complex with the Fc fragment. Interestingly, we found...

  8. The Barcelona Hospital Clínic therapeutic apheresis database.

    Science.gov (United States)

    Cid, Joan; Carbassé, Gloria; Cid-Caballero, Marc; López-Púa, Yolanda; Alba, Cristina; Perea, Dolores; Lozano, Miguel

    2017-09-22

    A therapeutic apheresis (TA) database helps to increase knowledge about indications and type of apheresis procedures that are performed in clinical practice. The objective of the present report was to describe the type and number of TA procedures that were performed at our institution in a 10-year period, from 2007 to 2016. The TA electronic database was created by transferring patient data from electronic medical records and consultation forms into a Microsoft Access database developed exclusively for this purpose. Since 2007, prospective data from every TA procedure were entered in the database. A total of 5940 TA procedures were performed: 3762 (63.3%) plasma exchange (PE) procedures, 1096 (18.5%) hematopoietic progenitor cell (HPC) collections, and 1082 (18.2%) TA procedures other than PEs and HPC collections. The overall trend for the time-period was progressive increase in total number of TA procedures performed each year (from 483 TA procedures in 2007 to 822 in 2016). The tracking trend of each procedure during the 10-year period was different: the number of PE and other type of TA procedures increased 22% and 2818%, respectively, and the number of HPC collections decreased 28%. The TA database helped us to increase our knowledge about various indications and type of TA procedures that were performed in our current practice. We also believe that this database could serve as a model that other institutions can use to track service metrics. © 2017 Wiley Periodicals, Inc.

  9. Charge exchange in ion-atom collisions

    International Nuclear Information System (INIS)

    Bransden, B.H.

    1990-01-01

    Charge exchange reactions in which electrons are transferred from one ion (or atom) to another during a collision have been studied both as interesting examples of rearrangement collisions and because of important applications in plasma physics. This article reviews the modern theory developed for use at non-relativistic energies, but excluding the thermal and very low energy region. (author)

  10. Plasma turbulence

    International Nuclear Information System (INIS)

    Horton, W.

    1998-07-01

    The origin of plasma turbulence from currents and spatial gradients in plasmas is described and shown to lead to the dominant transport mechanism in many plasma regimes. A wide variety of turbulent transport mechanism exists in plasmas. In this survey the authors summarize some of the universally observed plasma transport rates

  11. Therapeutic apheresis in the Republic of Macedonia - our five years experience (2000-2004).

    Science.gov (United States)

    Milovanceva-Popovska, M; Stojkovski, Lj; Grcevska, L; Dzikova, S; Ristovska, V; Gogovska, L; Polenakovic, M

    2006-07-01

    Membrane plasma exchange (PE) is a mode of extracorporeal blood purification. Since 1985 membrane PE has been in regular use at the Department of Nephrology, Medical Faculty of Skopje, R.Macedonia. In this paper we report on five years (2000-2004) of single centre plasma exchange activity. We performed 540 PE treatments (108 PE/per year) on 99 patients. The M/F ratio was 40/48. The patients underwent a median of 5.45 procedures (range, 1-16). The treated patients were from different Departments. Protocols for PE depend on the disease and its severity. PE were performed 2-4 times weekly using Gambro PF 2000 N filters with an adaptation of the Gambro AK10 dialysis machine or with the Gambro Prizma machine (2 cases). Blood access was achieved through femoral vein. Substitution was made with fresh frozen plasma and/or with 20% human albumin combined with Ringer's solution. An average amount of 2150 ml plasmafiltrate per treatment (respectively 30 to 40 ml plasmafiltrate/kg body weight) was eliminated. Most therapeutic procedures were performed on patients from the Department of Neurology. 63.6% of all patients were referred for Myasthenia gravis and the Guillian Barre syndrome. The total number of procedures per year has remained fairly stable, corresponding to a median of 5.4 treatments/100 000 inhabitants. We observed hypocalcaemia in 8% of the patients, urticarial reactions in 7.3%, pruritic reactions in 12%, and hypotension/headache in 6.8%. No major procedural complications were seen.

  12. Exchange market pressure

    NARCIS (Netherlands)

    Jager, H.; Klaassen, F.; Durlauf, S.N.; Blume, L.E.

    2010-01-01

    Currencies can be under severe pressure in the foreign exchange market, but in a fixed (or managed) exchange rate regime that is not fully visible via the change in the exchange rate. Exchange market pressure (EMP) is a concept developed to nevertheless measure the pressure in such cases. This

  13. Plasma properties

    International Nuclear Information System (INIS)

    Weitzner, H.

    1990-06-01

    This paper discusses the following topics: MHD plasma activity: equilibrium, stability and transport; statistical analysis; transport studies; edge physics studies; wave propagation analysis; basic plasma physics and fluid dynamics; space plasma; and numerical methods

  14. Plasma accelerators

    International Nuclear Information System (INIS)

    Bingham, R.; Angelis, U. de; Johnston, T.W.

    1991-01-01

    Recently attention has focused on charged particle acceleration in a plasma by a fast, large amplitude, longitudinal electron plasma wave. The plasma beat wave and plasma wakefield accelerators are two efficient ways of producing ultra-high accelerating gradients. Starting with the plasma beat wave accelerator (PBWA) and laser wakefield accelerator (LWFA) schemes and the plasma wakefield accelerator (PWFA) steady progress has been made in theory, simulations and experiments. Computations are presented for the study of LWFA. (author)

  15. Fractionation of equine antivenom using caprylic acid precipitation in combination with cationic ion-exchange chromatography.

    Science.gov (United States)

    Raweerith, Rutai; Ratanabanangkoon, Kavi

    2003-11-01

    A combined process of caprylic acid (CA) precipitation and ion-exchange chromatography on SP-Sepharose was studied as a means to fractionate pepsin-digested horse antivenom F(ab')(2) antibody. In the CA precipitation, the optimal concentration for fractionation of F(ab')(2) from pepsin-digested horse plasma was 2%, in which 89.61% of F(ab')(2) antibody activity was recovered in the supernatant with 1.5-fold purification. A significant amount of pepsin was not precipitated and remained active under these conditions. An analytical cation exchanger Protein-Pak SP 8HR HPLC column was tested to establish optimal conditions for the effective separation of IgG, albumin, pepsin and CA from the F(ab')(2) product. From these results, the supernatant from CA precipitation of pepsin-digested plasma was subjected to a SP-Sepharose column chromatography using a linear salt gradient. With stepwise elution, a peak containing F(ab')(2) antibody could be obtained by elution with 0.25 M NaCl. The total recovery of antibody was 65.56% with 2.91-fold purification, which was higher than that achieved by ammonium sulfate precipitation. This process simultaneously and effectively removed residual pepsin, high molecular weight aggregates and CA in the final F(ab')(2) product, and should be suitable for large-scale fractionation of therapeutic equine antivenoms.

  16. Pathogen inactivation in fresh frozen plasma using riboflavin and ultraviolet light: Effects on plasma proteins and coagulation factor VIII

    Directory of Open Access Journals (Sweden)

    Stanojković Zoran

    2011-01-01

    characteristics of conventional plasma, so it could be used for the treatment of pathological conditions that demand transfusion of fresh frozen plasma, or in patients with thrombotic thrombocytopenic purpure when we use therapeutic exchange of plasma.

  17. Plasma device

    International Nuclear Information System (INIS)

    Thode, L.E.

    1981-01-01

    A method is described for electron beam heating of a high-density plasma to drive a fast liner. An annular or solid relativistic electron beam is used to heat a plasma to kilovolt temperatures through streaming instabilities in the plasma. Energy deposited in the plasma then converges on a fast liner to explosively or ablatively drive the liner to implosion. (U.K.)

  18. Atoms in dense plasmas

    International Nuclear Information System (INIS)

    More, R.M.

    1987-01-01

    This paper covers some aspects of the theory of atomic processes in dense plasmas. Because the topic is very broad, a few general rules which give useful guidance about the typical behavior of dense plasmas have been selected. These rules are illustrated by semiclassical estimates, scaling laws and appeals to more elaborate calculations. Included in the paper are several previously unpublished results including a new mechanism for electron-ion heat exchange (section II), and an approximate expression for oscillator-strengths of highly charged ions (section V). However the main emphasis is not upon practical formulas but rather on questions of fundamental theory, the structural ingredients which must be used in building a model for plasma events. What are the density effects and how does one represent them? Which are most important? How does one identify an incorrect theory? The general rules help to answer these questions. 106 references, 23 figures, 2 tables

  19. The cAMP-activated GTP exchange factor, Epac1 Upregulates Plasma Membrane and Nuclear Akt Kinase Activities in 8-CPT-2-O-Me-cAMP-Stimulated Macrophages: Gene silencing of the cAMP-activated GTP exchange Epac1 prevents 8-CPT-2-O-Me-cAMP activation of Akt activity in macrophages*

    OpenAIRE

    Misra, Uma K.; Kaczowka, Steven; Pizzo, Salvatore V.

    2008-01-01

    cAMP regulates a wide range of processes through its downstream effectors including PKA, and the family of guanine nucleotide exchange factors. Depending on the cell type, cAMP inhibits or stimulates growth and proliferation in a PKA-dependent or independent manner. PKA-independent effects are mediated by PI 3-kinases-Akt signaling and EPAC1 (exchange protein directly activated by cAMP) activation. Recently, we reported PKA-independent activation of the protein kinase Akt as well co-immunopre...

  20. High-beta plasma blobs in the morningside plasma sheet

    Directory of Open Access Journals (Sweden)

    G. Haerendel

    1999-12-01

    Full Text Available Equator-S frequently encountered, i.e. on 30% of the orbits between 1 March and 17 April 1998, strong variations of the magnetic field strength of typically 5–15-min duration outside about 9RE during the late-night/early-morning hours. Very high-plasma beta values were found, varying between 1 and 10 or more. Close conjunctions between Equator-S and Geotail revealed the spatial structure of these "plasma blobs" and their lifetime. They are typically 5–10° wide in longitude and have an antisymmetric plasma or magnetic pressure distribution with respect to the equator, while being altogether low-latitude phenomena  (≤ 15°. They drift slowly sunward, exchange plasma across the equator and have a lifetime of at least 15–30 min. While their spatial structure may be due to some sort of mirror instability, little is known about the origin of the high-beta plasma. It is speculated that the morningside boundary layer somewhat further tailward may be the source of this plasma. This would be consistent with the preference of the plasma blobs to occur during quiet conditions, although they are also found during substorm periods. The relation to auroral phenomena in the morningside oval is uncertain. The energy deposition may be mostly too weak to generate a visible signature. However, patchy aurora remains a candidate for more disturbed periods.Key words. Magnetospheric physics (plasma convection; plasma sheet; plasma waves and instabilities

  1. Edge plasma physical investigations of tokamak plasmas in CRIP

    International Nuclear Information System (INIS)

    Bakos, J.; Ignacz, P.; Koltai, L.; Paszti, F.; Petravich, G.; Szigeti, J.; Zoletnik, S.

    1988-01-01

    The results of the measurements performed in the field of thermonuclear high temperature plasma physics in CRIP (Hungary) are summarized. In the field of the edge plasma physics solid probes were used to test the external zone of plasma edges, and atom beams and balls were used to investigate both the external and internal zones. The plasma density distribution was measured by laser blow-off technics, using Na atoms, which are evaporated by laser pulses. The excitation of Na atom ball by tokamak plasma gives information on the status of the plasma edge. The toroidal asymmetry of particle transport in tokamak plasma was measured by erosion probes. The evaporated and transported impurities were collected on an other part of the plasma edge and were analyzed by SIMS and Rutherford backscattering. The interactions in plasma near the limiter were investigated by a special limiter with implemented probes. Recycling and charge exchange processes were measured. Disruption phenomena of tokamak plasma were analyzed and a special kind of disruptions, 'soft disruptions' and the related preliminary perturbations were discovered. (D.Gy.) 10 figs

  2. Plasma Modes

    Science.gov (United States)

    Dubin, D. H. E.

    This chapter explores several aspects of the linear electrostatic normal modes of oscillation for a single-species non-neutral plasma in a Penning trap. Linearized fluid equations of motion are developed, assuming the plasma is cold but collisionless, which allow derivation of the cold plasma dielectric tensor and the electrostatic wave equation. Upper hybrid and magnetized plasma waves in an infinite uniform plasma are described. The effect of the plasma surface in a bounded plasma system is considered, and the properties of surface plasma waves are characterized. The normal modes of a cylindrical plasma column are discussed, and finally, modes of spheroidal plasmas, and finite temperature effects on the modes, are briefly described.

  3. Charge exchange in galaxy clusters

    Science.gov (United States)

    Gu, Liyi; Mao, Junjie; de Plaa, Jelle; Raassen, A. J. J.; Shah, Chintan; Kaastra, Jelle S.

    2018-03-01

    Context. Though theoretically expected, the charge exchange emission from galaxy clusters has never been confidently detected. Accumulating hints were reported recently, including a rather marginal detection with the Hitomi data of the Perseus cluster. As previously suggested, a detection of charge exchange line emission from galaxy clusters would not only impact the interpretation of the newly discovered 3.5 keV line, but also open up a new research topic on the interaction between hot and cold matter in clusters. Aim. We aim to perform the most systematic search for the O VIII charge exchange line in cluster spectra using the RGS on board XMM-Newton. Methods: We introduce a sample of 21 clusters observed with the RGS. In order to search for O VIII charge exchange, the sample selection criterion is a >35σ detection of the O VIII Lyα line in the archival RGS spectra. The dominating thermal plasma emission is modeled and subtracted with a two-temperature thermal component, and the residuals are stacked for the line search. The systematic uncertainties in the fits are quantified by refitting the spectra with a varying continuum and line broadening. Results: By the residual stacking, we do find a hint of a line-like feature at 14.82 Å, the characteristic wavelength expected for oxygen charge exchange. This feature has a marginal significance of 2.8σ, and the average equivalent width is 2.5 × 10-4 keV. We further demonstrate that the putative feature can be barely affected by the systematic errors from continuum modeling and instrumental effects, or the atomic uncertainties of the neighboring thermal lines. Conclusions: Assuming a realistic temperature and abundance pattern, the physical model implied by the possible oxygen line agrees well with the theoretical model proposed previously to explain the reported 3.5 keV line. If the charge exchange source indeed exists, we expect that the oxygen abundance could have been overestimated by 8-22% in previous X

  4. Collection of heparinized plasma by plasmapheresis

    NARCIS (Netherlands)

    van der Meer, P. F.; Vrielink, H.; Pietersz, R. N.; Dekker, W. J.; Reesink, H. W.

    1999-01-01

    BACKGROUND AND OBJECTIVES: Heparinized plasma can be used for exchange transfusions in neonates and is usually collected by drawing whole blood using heparin as anticoagulant. The heparinized red blood cells and buffy coat cannot be used and are therefore discarded. To collect heparinized plasma

  5. Isotopically exchangeable phosphorus

    International Nuclear Information System (INIS)

    Barbaro, N.O.

    1984-01-01

    A critique revision of isotope dilution is presented. The concepts and use of exchangeable phosphorus, the phosphate adsorption, the kinetics of isotopic exchange and the equilibrium time in soils are discussed. (M.A.C.) [pt

  6. NCHRP peer exchange 2008.

    Science.gov (United States)

    2008-09-01

    Peer exchanges for state department of transportation (DOT) research programs originated with : the Intermodal Surface Transportation Efficiency Act of 1991 (ISTEA). That federal legislation : required the states to conduct periodic peer exchanges to...

  7. Indiana Health Information Exchange

    Science.gov (United States)

    The Indiana Health Information Exchange is comprised of various Indiana health care institutions, established to help improve patient safety and is recognized as a best practice for health information exchange.

  8. Fundamentals of ion exchange

    International Nuclear Information System (INIS)

    Townsend, R.P.

    1993-01-01

    In this paper the fundamentals of ion exchange mechanisms and their thermodynamics are described. A range of ion exchange materials is considered and problems of communication and technology transfer between scientists working in the field are discussed. (UK)

  9. Therapeutic HIV Peptide Vaccine

    DEFF Research Database (Denmark)

    Fomsgaard, Anders

    2015-01-01

    Therapeutic vaccines aim to control chronic HIV infection and eliminate the need for lifelong antiretroviral therapy (ART). Therapeutic HIV vaccine is being pursued as part of a functional cure for HIV/AIDS. We have outlined a basic protocol for inducing new T cell immunity during chronic HIV-1...... infection directed to subdominant conserved HIV-1 epitopes restricted to frequent HLA supertypes. The rationale for selecting HIV peptides and adjuvants are provided. Peptide subunit vaccines are regarded as safe due to the simplicity, quality, purity, and low toxicity. The caveat is reduced immunogenicity...

  10. Plasma centrifuges

    International Nuclear Information System (INIS)

    Karchevskij, A.I.; Potanin, E.P.

    2000-01-01

    The review of the most important studies on the isotope separation processes in the rotating plasma is presented. The device is described and the characteristics of operation of the pulse plasma centrifuges with weakly and strongly ionized plasma as well as the stationary plasma centrifuges with the medium weak ionization and devices, applying the stationary vacuum arc with the high ionization rate and the stationary beam-plasma discharge with complete ionization, are presented. The possible mechanisms of the isotope separation in plasma centrifuges are considered. The specific energy consumption for isotope separation in these devices is discussed [ru

  11. Plasma astrophysics

    CERN Document Server

    Kaplan, S A; ter Haar, D

    2013-01-01

    Plasma Astrophysics is a translation from the Russian language; the topics discussed are based on lectures given by V.N. Tsytovich at several universities. The book describes the physics of the various phenomena and their mathematical formulation connected with plasma astrophysics. This book also explains the theory of the interaction of fast particles plasma, their radiation activities, as well as the plasma behavior when exposed to a very strong magnetic field. The text describes the nature of collective plasma processes and of plasma turbulence. One author explains the method of elementary

  12. Plasma waves

    CERN Document Server

    Swanson, DG

    1989-01-01

    Plasma Waves discusses the basic development and equations for the many aspects of plasma waves. The book is organized into two major parts, examining both linear and nonlinear plasma waves in the eight chapters it encompasses. After briefly discussing the properties and applications of plasma wave, the book goes on examining the wave types in a cold, magnetized plasma and the general forms of the dispersion relation that characterize the waves and label the various types of solutions. Chapters 3 and 4 analyze the acoustic phenomena through the fluid model of plasma and the kinetic effects. Th

  13. Plasma and tissue insulin-like growth factor-I receptor (IGF-IR) as a prognostic marker for prostate cancer and anti-IGF-IR agents as novel therapeutic strategy for refractory cases: a review.

    Science.gov (United States)

    Ozkan, Emine Elif

    2011-09-15

    Cancer database analysis indicates that prostate cancer is one of the most seen cancers in men meanwhile composing the leading cause of morbidity and mortality among developed countries. Current available therapies are surgery, radiotherapy and androgene ablation for prostate carcinoma. The response rate is as high nearly 90% however, most of these recur or become refractory and androgene independent (AI). Therefore recent studies intensified on molecular factors playing role on development of prostate carcinoma and novel treatment strategies targetting these factors and their receptors. Insulin-like growth factor-I (IGF-I) and its primary receptor insulin-like growth factor receptor-I (IGF-IR) are among these factors. Biologic functions and role in malign progression are primarily achieved via IGF-IR which is a type 2 tyrosine kinase receptor. IGF-IR plays an important role in mitogenesis, angiogenesis, transformation, apoptosis and cell motility. It also generates intensive proliferative signals leading to carcinogenesis in prostate tissue. So IGF-IR and its associated signalling system have provoked considerable interest over recent years as a novel therapeutic target in cancer. In this paper it is aimed to sum up the lately published literature searching the relation of IGF-IR and prostate cancer in terms of incidence, pathologic features, and prognosis. This is followed by a discussion of the different possible targets within the IGF-1R system, and drugs developed to interact at each target. A systems-based approach is then used to review the in vitro and in vivo data in the published literature of the following compounds targeting IGF-1R components using specific examples: growth hormone releasing hormone antagonists (e.g. JV-1-38), growth hormone receptor antagonists (e.g. pegvisomant), IGF-1R antibodies (e.g. CP-751,871, AVE1642/EM164, IMC-A12, SCH-717454, BIIB022, AMG 479, MK-0646/h7C10), and IGF-1R tyrosine kinase inhibitors (e.g. BMS-536942, BMS-554417

  14. Plasma Discharge Process in a Pulsed Diaphragm Discharge System

    Science.gov (United States)

    Duan, Jianjin; Hu, Jue; Zhang, Chao; Wen, Yuanbin; Meng, Yuedong; Zhang, Chengxu

    2014-12-01

    As one of the most important steps in wastewater treatment, limited study on plasma discharge process is a key challenge in the development of plasma applications. In this study, we focus on the plasma discharge process of a pulsed diaphragm discharge system. According to the analysis, the pulsed diaphragm discharge proceeds in seven stages: (1) Joule heating and heat exchange stage; (2) nucleated site formation; (3) plasma generation (initiation of the breakdown stage); (4) avalanche growth and plasma expansion; (5) plasma contraction; (6) termination of the plasma discharge; and (7) heat exchange stage. From this analysis, a critical voltage criterion for breakdown is obtained. We anticipate this finding will provide guidance for a better application of plasma discharges, especially diaphragm plasma discharges.

  15. Marketing therapeutic recreation services.

    Science.gov (United States)

    Thorn, B E

    1984-01-01

    The use of marketing strategies can enhance the delivery of therapeutic recreation services. This article discusses how agencies can adapt marketing techniques and use them to identify potential markets, improve image, evaluate external pressures, and maximize internal strengths. Four variables that can be controlled and manipulated in a proposed marketing plan are product, price, place and promotion.

  16. Therapeutic Recombinant Monoclonal Antibodies

    Science.gov (United States)

    Bakhtiar, Ray

    2012-01-01

    During the last two decades, the rapid growth of biotechnology-derived techniques has led to a myriad of therapeutic recombinant monoclonal antibodies with significant clinical benefits. Recombinant monoclonal antibodies can be obtained from a number of natural sources such as animal cell cultures using recombinant DNA engineering. In contrast to…

  17. Therapeutic applications of radiopharmaceuticals

    International Nuclear Information System (INIS)

    Baker, W.J.; Datz, F.L.; Beightol, R.W.

    1987-01-01

    Whether a radiopharmaceutical has diagnostic or therapeutic application depends on both the isotope and pharmaceutical used. For diagnostic applications, the isotope should undergo only γ-decay, since usually only γ-radiation is detected by nuclear medicine cameras. The half-life should be just long enough to allow the procedure to be performed. In contrast, the isotope needed for therapeutic purposes should have particulate radiation, such as a β-particle (electron), since these are locally absorbed an increase the local radiation dose. γ-Radiation, which penetrates the tissues, produces less radiation dose than do Β-particles. Several references dealing with radioactive decay, particulate interactions, and diagnostic and therapeutic applications of radiopharmaceuticals are available. Radiopharmaceuticals can legally be used only by physicians who are qualified by specific training in the safe handling of radionuclides. The experience and training of these physicians must be approved by the Nuclear Regulatory Commission or Agreement State Agency authorized to license the use of radiopharmaceuticals. A list of all byproduct material and procedures is available in the Code of Federal Regulations. Of the many radiopharmaceuticals available for diagnostic and therapeutic use, only those commonly used are discussed in this chapter

  18. Exchange rate policy

    Directory of Open Access Journals (Sweden)

    Plačkov Slađana

    2013-01-01

    Full Text Available Small oscillations of exchange rate certainly affect the loss of confidence in the currency (Serbian dinar, CSD and because of the shallow market even the smallest change in the supply and demand leads to a shift in exchange rate and brings uncertainty. Some economists suggest that the course should be linked to inflation and thus ensure predictable and stable exchange rates. Real exchange rate or slightly depressed exchange rate will encourage the competitiveness of exporters and perhaps ensure the development of new production lines which, in terms of overvalued exchange rate, had no economic justification. Fixed exchange rate will bring lower interest rates, lower risk and lower business uncertainty (uncertainty avoidance, but Serbia will also reduce foreign exchange reserves by following this trend. On the other hand, a completely free exchange rate, would lead to a (real fall of Serbian currency, which in a certain period would lead to a significant increase in exports, but the consequences for businessmen and citizens with loans pegged to the euro exchange rate, would be disastrous. We will pay special attention to the depreciation of the exchange rate, as it is generally favorable to the export competitiveness of Serbia and, on the other hand, it leads to an increase in debt servicing costs of the government as well as of the private sector. Oscillations of the dinar exchange rate, appreciation and depreciation, sometimes have disastrous consequences on the economy, investors, imports and exports. In subsequent work, we will observe the movement of the dinar exchange rate in Serbia, in the time interval 2009-2012, in order to strike a balance and maintain economic equilibrium. A movement of foreign currencies against the local currency is controlled in the foreign exchange market, so in case economic interests require, The National Bank of Serbia (NBS, on the basis of arbitrary criteria, can intervene in the market.

  19. Plasma device

    International Nuclear Information System (INIS)

    Thode, L.E.

    1981-01-01

    A method is described of providing electron beam heating of a high-density plasma to drive a fast liner to implode a structured microsphere. An annular relativistic electron beam is used to heat an annular plasma to kilovolt temperatures through streaming instabilities in the plasma. Energy deposited in the annular plasma then converges on a fast liner to explosively or ablatively drive the liner to convergence to implode the structured microsphere. (U.K.)

  20. Low Temperature Plasma Medicine

    Science.gov (United States)

    Graves, David

    2013-10-01

    Ionized gas plasmas near room temperature are used in a remarkable number of technological applications mainly because they are extraordinarily efficient at exploiting electrical power for useful chemical and material transformations near room temperature. In this tutorial address, I will focus on the newest area of low temperature ionized gas plasmas (LTP), in this case operating under atmospheric pressure conditions, in which the temperature-sensitive material is living tissue. LTP research directed towards biomedical applications such as sterilization, surgery, wound healing and anti-cancer therapy has seen remarkable growth in the last 3-5 years, but the mechanisms responsible for the biomedical effects have remained mysterious. It is known that LTP readily create reactive oxygen species (ROS) and reactive nitrogen species (RNS). ROS and RNS (or RONS), in addition to a suite of other radical and non-radical reactive species, are essential actors in an important sub-field of aerobic biology termed ``redox'' (or oxidation-reduction) biology. I will review the evidence suggesting that RONS generated by plasmas are responsible for their observed therapeutic effects. Other possible bio-active mechanisms include electric fields, charges and photons. It is common in LTP applications that synergies between different mechanisms can play a role and I will review the evidence for synergies in plasma biomedicine. Finally, I will address the challenges and opportunities for plasma physicists to enter this novel, multidisciplinary field.

  1. Automated exchange transfusion and exchange rate.

    Science.gov (United States)

    Funato, M; Shimada, S; Tamai, H; Taki, H; Yoshioka, Y

    1989-10-01

    An automated blood exchange transfusion (BET) with a two-site technique has been devised by Goldmann et al and by us, using an infusion pump. With this method, we successfully performed exchange transfusions 189 times in the past four years on 110 infants with birth weights ranging from 530 g to 4,000 g. The exchange rate by the automated method was compared with the rate by Diamond's method. Serum bilirubin (SB) levels before and after BET and the maximal SB rebound within 24 hours after BET were: 21.6 +/- 2.4, 11.5 +/- 2.2, and 15.0 +/- 1.5 mg/dl in the automated method, and 22.0 +/- 2.9, 11.2 +/- 2.5, and 17.7 +/- 3.2 mg/dl in Diamond's method, respectively. The result showed that the maximal rebound of the SB level within 24 hours after BET was significantly lower in the automated method than in Diamond's method (p less than 0.01), though SB levels before and after BET were not significantly different between the two methods. The exchange rate was also measured by means of staining the fetal red cells (F cells) both in the automated method and in Diamond's method, and comparing them. The exchange rate of F cells in Diamond's method went down along the theoretical exchange curve proposed by Diamond, while the rate in the automated method was significantly better than in Diamond's, especially in the early stage of BET (p less than 0.01). We believe that the use of this automated method may give better results than Diamond's method in the rate of exchange, because this method is performed with a two-site technique using a peripheral artery and vein.

  2. Clinically Relevant Anticancer Polymer Paclitaxel Therapeutics

    Directory of Open Access Journals (Sweden)

    Danbo Yang

    2010-12-01

    Full Text Available The concept of utilizing polymers in drug delivery has been extensively explored for improving the therapeutic index of small molecule drugs. In general, polymers can be used as polymer-drug conjugates or polymeric micelles. Each unique application mandates its own chemistry and controlled release of active drugs. Each polymer exhibits its own intrinsic issues providing the advantage of flexibility. However, none have as yet been approved by the U.S. Food and Drug Administration. General aspects of polymer and nano-particle therapeutics have been reviewed. Here we focus this review on specific clinically relevant anticancer polymer paclitaxel therapeutics. We emphasize their chemistry and formulation, in vitro activity on some human cancer cell lines, plasma pharmacokinetics and tumor accumulation, in vivo efficacy, and clinical outcomes. Furthermore, we include a short review of our recent developments of a novel poly(L-g-glutamylglutamine-paclitaxel nano-conjugate (PGG-PTX. PGG-PTX has its own unique property of forming nano-particles. It has also been shown to possess a favorable profile of pharmacokinetics and to exhibit efficacious potency. This review might shed light on designing new and better polymer paclitaxel therapeutics for potential anticancer applications in the clinic.

  3. Clinically Relevant Anticancer Polymer Paclitaxel Therapeutics

    International Nuclear Information System (INIS)

    Yang, Danbo; Yu, Lei; Van, Sang

    2010-01-01

    The concept of utilizing polymers in drug delivery has been extensively explored for improving the therapeutic index of small molecule drugs. In general, polymers can be used as polymer-drug conjugates or polymeric micelles. Each unique application mandates its own chemistry and controlled release of active drugs. Each polymer exhibits its own intrinsic issues providing the advantage of flexibility. However, none have as yet been approved by the U.S. Food and Drug Administration. General aspects of polymer and nano-particle therapeutics have been reviewed. Here we focus this review on specific clinically relevant anticancer polymer paclitaxel therapeutics. We emphasize their chemistry and formulation, in vitro activity on some human cancer cell lines, plasma pharmacokinetics and tumor accumulation, in vivo efficacy, and clinical outcomes. Furthermore, we include a short review of our recent developments of a novel poly(l-γ-glutamylglutamine)-paclitaxel nano-conjugate (PGG-PTX). PGG-PTX has its own unique property of forming nano-particles. It has also been shown to possess a favorable profile of pharmacokinetics and to exhibit efficacious potency. This review might shed light on designing new and better polymer paclitaxel therapeutics for potential anticancer applications in the clinic

  4. Clinically Relevant Anticancer Polymer Paclitaxel Therapeutics

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Danbo [Biomedical Engineering and Technology Institute, Institutes for Advanced Interdisciplinary Research, East China Normal University, 3663 North Zhongshan Road, Shanghai, 200062 (China); Yu, Lei, E-mail: yu-lei@gg.nitto.co.jp [Biomedical Engineering and Technology Institute, Institutes for Advanced Interdisciplinary Research, East China Normal University, 3663 North Zhongshan Road, Shanghai, 200062 (China); Biomedical Group, Nitto Denko Technical Corporation, 501 Via Del Monte, Oceanside, CA 92058 (United States); Van, Sang [Biomedical Group, Nitto Denko Technical Corporation, 501 Via Del Monte, Oceanside, CA 92058 (United States)

    2010-12-23

    The concept of utilizing polymers in drug delivery has been extensively explored for improving the therapeutic index of small molecule drugs. In general, polymers can be used as polymer-drug conjugates or polymeric micelles. Each unique application mandates its own chemistry and controlled release of active drugs. Each polymer exhibits its own intrinsic issues providing the advantage of flexibility. However, none have as yet been approved by the U.S. Food and Drug Administration. General aspects of polymer and nano-particle therapeutics have been reviewed. Here we focus this review on specific clinically relevant anticancer polymer paclitaxel therapeutics. We emphasize their chemistry and formulation, in vitro activity on some human cancer cell lines, plasma pharmacokinetics and tumor accumulation, in vivo efficacy, and clinical outcomes. Furthermore, we include a short review of our recent developments of a novel poly(l-γ-glutamylglutamine)-paclitaxel nano-conjugate (PGG-PTX). PGG-PTX has its own unique property of forming nano-particles. It has also been shown to possess a favorable profile of pharmacokinetics and to exhibit efficacious potency. This review might shed light on designing new and better polymer paclitaxel therapeutics for potential anticancer applications in the clinic.

  5. Empirical Correction for Differences in Chemical Exchange Rates in Hydrogen Exchange-Mass Spectrometry Measurements.

    Science.gov (United States)

    Toth, Ronald T; Mills, Brittney J; Joshi, Sangeeta B; Esfandiary, Reza; Bishop, Steven M; Middaugh, C Russell; Volkin, David B; Weis, David D

    2017-09-05

    A barrier to the use of hydrogen exchange-mass spectrometry (HX-MS) in many contexts, especially analytical characterization of various protein therapeutic candidates, is that differences in temperature, pH, ionic strength, buffering agent, or other additives can alter chemical exchange rates, making HX data gathered under differing solution conditions difficult to compare. Here, we present data demonstrating that HX chemical exchange rates can be substantially altered not only by the well-established variables of temperature and pH but also by additives including arginine, guanidine, methionine, and thiocyanate. To compensate for these additive effects, we have developed an empirical method to correct the hydrogen-exchange data for these differences. First, differences in chemical exchange rates are measured by use of an unstructured reporter peptide, YPI. An empirical chemical exchange correction factor, determined by use of the HX data from the reporter peptide, is then applied to the HX measurements obtained from a protein of interest under different solution conditions. We demonstrate that the correction is experimentally sound through simulation and in a proof-of-concept experiment using unstructured peptides under slow-exchange conditions (pD 4.5 at ambient temperature). To illustrate its utility, we applied the correction to HX-MS excipient screening data collected for a pharmaceutically relevant IgG4 mAb being characterized to determine the effects of different formulations on backbone dynamics.

  6. Outlook for ion exchange

    International Nuclear Information System (INIS)

    Kunin, R.

    1977-01-01

    This paper presents the history and theory of ion exchange technology and discusses the usefulness of ion exchange resins which found broad applications in chemical operations. It is demonstrated that the theory of ion exchange technology seems to be moving away from the physical chemist back to the polymer chemist where it started originally. This but confronted the polymer chemists with some knotty problems. It is pointed out that one has still to learn how to use ion exchange materials as efficiently as possible in terms of the waste load that is being pumped into the environment. It is interesting to note that, whereas ion exchange is used for abating pollution, it is also a polluter. One must learn how to use ion exchange as an antipollution device, and at the same time minimize its polluting properties

  7. Dusty plasmas

    International Nuclear Information System (INIS)

    Jones, M.E.; Winske, D.; Keinigs, R.; Lemons, D.

    1996-01-01

    This is the final report of a three-year, Laboratory-Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The objective of this project has been to develop a fundamental understanding of dusty plasmas at the Laboratory. While dusty plasmas are found in space in galactic clouds, planetary rings, and cometary tails, and as contaminants in plasma enhanced fabrication of microelectronics, many of their properties are only partially understood. Our work has involved both theoretical analysis and self-consistent plasma simulations to understand basic properties of dusty plasmas related to equilibrium, stability, and transport. Such an understanding can improve the control and elimination of plasma dust in industrial applications and may be important in the study of planetary rings and comet dust tails. We have applied our techniques to the study of charging, dynamics, and coagulation of contaminants in plasma processing reactors for industrial etching and deposition processes and to instabilities in planetary rings and other space plasma environments. The work performed in this project has application to plasma kinetics, transport, and other classical elementary processes in plasmas as well as to plasma waves, oscillations, and instabilities

  8. Plasma chromatography

    International Nuclear Information System (INIS)

    Anon.

    1984-01-01

    This book examines the fundamental theory and various applications of ion mobility spectroscopy. Plasma chromatography developed from research on the diffusion and mobility of ions. Topics considered include instrument design and description (e.g., performance, spectral interpretation, sample handling, mass spectrometry), the role of ion mobility in plasma chromatography (e.g., kinetic theory of ion transport), atmospheric pressure ionization (e.g., rate equations), the characterization of isomers by plasma chromatography (e.g., molecular ion characteristics, polynuclear aromatics), plasma chromatography as a gas chromatographic detection method (e.g., qualitative analysis, continuous mobility monitoring, quantitative analysis), the analysis of toxic vapors by plasma chromatography (e.g., plasma chromatograph calibration, instrument control and data processing), the analysis of semiconductor devices and microelectronic packages by plasma chromatography/mass spectroscopy (e.g., analysis of organic surface contaminants, analysis of water in sealed electronic packages), and instrument design and automation (hardware, software)

  9. Microsoft Exchange 2013 cookbook

    CERN Document Server

    Van Horenbeeck, Michael

    2013-01-01

    This book is a practical, hands-on guide that provides the reader with a number of clear, step-by-step exercises.""Microsoft Exchange 2013 Cookbook"" is targeted at network administrators who deal with the Exchange server in their day-to-day jobs. It assumes you have some practical experience with previous versions of Exchange (although this is not a requirement), without being a subject matter expert.

  10. PYTHIOSIS: A THERAPEUTIC APPROACH

    Directory of Open Access Journals (Sweden)

    C. M. C. Falcão

    2015-10-01

    Full Text Available Pythiosis, a disease caused by the oomycete Pythium insidiosum, often presents inefficient response to chemotherapy. It is a consensus that, in spite the several therapeutic protocols, a combination of surgery, chemotherapy and immunotherapy should be used. Surgical excision requires the removal of the entire affected area, with a wide margin of safety. The use of antifungal drugs has resulted in variable results, both in vitro and in vivo, and presents low therapeutic efficiency due to differences in the agent characteristics, which differ from true fungi. Immunotherapy is a non-invasive alternative for the treatment of pythiosis, which aims at modifying the immune response of the host, thereby producing an effective response to the agent. Photodynamic therapy has emerged as a promising technique, with good activity against P. insidiosum in vitro and in vivo. However, more studies are necessary to increase the efficiency of the current treatment protocols and consequently improve the cure rates. This paper aims to conduct a review covering the conventional and recent therapeutic methods against P. insidiosum infections

  11. Towards plasma surgery: interactions of cold plasmas with living cells paper (invited talk), Proceedings vol. 2. 1049-1052

    NARCIS (Netherlands)

    Stoffels, E.; Kieft, I.E.; Sladek, R.E.J.; Laan, van der E.P.

    2004-01-01

    High-precision treatment of living tissues with a cold atmospheric plasma promises to become the "surgery of the future". Initial studies on plasma-cell interactions have revealed numerous therapeutically useful cell responses. In contrast to the conventional or laser surgery, plasma treatment does

  12. Reactor fuel exchanging facility

    International Nuclear Information System (INIS)

    Kubota, Shin-ichi.

    1981-01-01

    Purpose: To enable operation of an emergency manual operating mechanism for a fuel exchanger with all operatorless trucks and remote operation of a manipulator even if the exchanger fails during the fuel exchanging operation. Constitution: When a fuel exchanging system fails while connected to a pressure tube of a nuclear reactor during a fuel exchanging operation, a stand-by self-travelling truck automatically runs along a guide line to the position corresponding to the stopping position at that time of the fuel exchanger based on a command from a central control chamber. At this time the truck is switched to manual operation, and approaches the exchanger while being monitored through a television camera and then stops. Then, a manipurator is connected to the emergency manual operating mechanism of the exchanger, and is operated through necessary emergency steps by driving the snout, the magazine, the grab or the like in the exchanger in response to the problem, and necessary operations for the emergency treatment are thus performed. (Sekiya, K.)

  13. Controlled fusion and plasma physics

    International Nuclear Information System (INIS)

    1994-07-01

    40 papers are presented at this 21. conference on controlled fusion and plasma physics (JET). Titles are: effects of sawtooth crashes on beams ions and fusion product tritons; beta limits in H-modes and VH-modes; impurity induced neutralization of MeV energy protons in JET plasmas; lost α particle diagnostic for high-yield D-T fusion plasmas; 15-MeV proton emission from ICRF-heated plasmas; pulse compression radar reflectometry for density measurements; gamma-ray emission profile measurements during ICRH discharges; the new JET phase ICRH array; simulation of triton burn-up; parametric dependencies of JET electron temperature profiles; detached divertor plasmas; excitation of global Alfven Eigenmodes by RF heating; mechanisms of toroidal rotation; effect of shear in the radial electric field on confinement; plasma transport properties at the L-H transition; numerical study of plasma detachment conditions in JET divertor plasmas; the SOL width and the MHD interchange instability; non linear magnetic reconnection in low collisionality plasmas; topology and slowing down of high energy ion orbits; sawtooth crashes at high beta; fusion performances and alpha heating in future JET D-T plasmas; a stable route to high-beta plasmas with non-monotonic q-profiles; theory of propagation of changes to confinement; spatial distribution of gamma emissivity and fast ions during ICRF heating; multi-camera soft X-ray diagnostic; radiation phenomena and particle fluxes in the X-event; local measurement of transport parameters for laser injected trace impurities; impurity transport of high performance discharges; negative snakes and negative shear; neural-network charge exchange analysis; ion temperature anisotropy in helium neutral beam fuelling; impurity line emission due to thermal charge exchange in edge plasmas; control of convection by fuelling and pumping; VH mode accessibility and global H-mode properties; ion cyclotron emission by spontaneous emission; LHCD/ICRH synergy

  14. GRUNDTVIG in transnational exchange

    DEFF Research Database (Denmark)

    Grundtvig in transnational exchange is the report from the seminar in december 2015 in cooperation with University of Cape Town and University of Hamburg.......Grundtvig in transnational exchange is the report from the seminar in december 2015 in cooperation with University of Cape Town and University of Hamburg....

  15. Building Relationships through Exchange

    Science.gov (United States)

    Primavera, Angi; Hall, Ellen

    2011-01-01

    From the moment of birth, children form and develop relationships with others in their world based on exchange. Children recognize that engaging in such encounters offers them the opportunity to enter into a relationship with another individual and to nurture that relationship through the exchange of messages and gifts, items and ideas. At Boulder…

  16. Exotic baryonium exchanges

    International Nuclear Information System (INIS)

    Nicolescu, B.

    1978-05-01

    The prominent effects supposed to be associated with the exchange of exotic baryonium Regge trajectories are reviewed. The experimental presence of all expected effects leads to suggest that the baryonium exchange mechanism is a correct phenomenological picture and that mesons with isospin 2 or 3/2 or with strangeness 2, strongly coupled to the baryon-antibaryon channels, must be observed

  17. Optimization of Heat Exchangers

    International Nuclear Information System (INIS)

    Catton, Ivan

    2010-01-01

    The objective of this research is to develop tools to design and optimize heat exchangers (HE) and compact heat exchangers (CHE) for intermediate loop heat transport systems found in the very high temperature reator (VHTR) and other Generation IV designs by addressing heat transfer surface augmentation and conjugate modeling. To optimize heat exchanger, a fast running model must be created that will allow for multiple designs to be compared quickly. To model a heat exchanger, volume averaging theory, VAT, is used. VAT allows for the conservation of mass, momentum and energy to be solved for point by point in a 3 dimensional computer model of a heat exchanger. The end product of this project is a computer code that can predict an optimal configuration for a heat exchanger given only a few constraints (input fluids, size, cost, etc.). As VAT computer code can be used to model characteristics (pumping power, temperatures, and cost) of heat exchangers more quickly than traditional CFD or experiment, optimization of every geometric parameter simultaneously can be made. Using design of experiment, DOE and genetric algorithms, GE, to optimize the results of the computer code will improve heat exchanger design.

  18. Stroke and Therapeutic Hypothermia

    Directory of Open Access Journals (Sweden)

    Ozlem Ozkan Kuscu

    2016-09-01

    Full Text Available Stroke is significant cause of morbidity and mortality caused by disruption of blood flow. Neural injury occurs with two stage; while primary neural injury occurs with disruption of blood flow, after days and hours with metabolic processes secondary injury develops in tissues which is non injured in the first stage. Therefore it is important to prevent and treat the secondary injury as much as preventing and treating the primary neural injury. In this article developing pathophysiological changes after stroke, mechanisms of therapeutic hypothermia, application methods, the factors that determine the effectiveness, side effects and complications were reviewed. [Archives Medical Review Journal 2016; 25(3.000: 351-368

  19. Standardizing exchange formats

    International Nuclear Information System (INIS)

    Lemmel, H.D.; Schmidt, J.J.

    1992-01-01

    An international network of co-operating data centres is described who maintain identical data bases which are simultaneously updated by an agreed data exchange procedure. The agreement covers ''data exchange formats'' which are compatible to the centres' internal data storage and retrieval systems which remain different, optimized at each centre to the available computer facilities and to the needs of the data users. Essential condition for the data exchange is an agreement on common procedures for the data exchange is an agreement on common procedures for the data compilation, including critical data analysis and validation. The systems described (''EXFOR'', ''ENDF'', ''CINDA'') are used for ''nuclear reaction data'', but the principles used for data compilation and exchange should be valid also for other data types. (author). 24 refs, 4 figs

  20. Plasma physics

    CERN Document Server

    Drummond, James E

    1961-01-01

    A historic snapshot of the field of plasma physics, this fifty-year-old volume offers an edited collection of papers by pioneering experts in the field. In addition to assisting students in their understanding of the foundations of classical plasma physics, it provides a source of historic context for modern physicists. Highly successful upon its initial publication, this book was the standard text on plasma physics throughout the 1960s and 70s.Hailed by Science magazine as a ""well executed venture,"" the three-part treatment ranges from basic plasma theory to magnetohydrodynamics and microwa

  1. Plasma generator

    International Nuclear Information System (INIS)

    Omichi, Takeo; Yamanaka, Toshiyuki.

    1976-01-01

    Object: To recycle a coolant in a sealed hollow portion formed interiorly of a plasma limiter itself to thereby to cause direct contact between the coolant and the plasma limiter and increase of contact area therebetween to cool the plasma limiter. Structure: The heat resulting from plasma generated during operation and applied to the body of the plasma limiter is transmitted to the coolant, which recycles through an inlet and outlet pipe, an inlet and outlet nozzle and a hollow portion to hold the plasma limiter at a level less than a predetermined temperature. On the other hand, the heater wire is, at the time of emergency operation, energized to heat the plasma limiter, but this heat is transmitted to the limiter body to increase the temperature thereof. However, the coolant recycling the hollow portion comes into direct contact with the limiter body, and since the plasma limiter surround the hollow portion, the heat amount transmitted from the limiter body to the coolant increases to sufficiently cool the plasma limiter. (Yoshihara, H.)

  2. Pharmacogenetics approach to therapeutics.

    Science.gov (United States)

    Koo, Seok Hwee; Lee, Edmund Jon Deoon

    2006-01-01

    1. Pharmacogenetics refers to the study of genetically controlled variations in drug response. Functional variants caused by single nucleotide polymorphisms (SNPs) in genes encoding drug-metabolising enzymes, transporters, ion channels and drug receptors have been known to be associated with interindividual and interethnic variation in drug response. Genetic variations in these genes play a role in influencing the efficacy and toxicity of medications. 2. Rapid, precise and cost-effective high-throughput technological platforms are essential for performing large-scale mutational analysis of genetic markers involved in the aetiology of variable responses to drug therapy. 3. The application of a pharmacogenetics approach to therapeutics in general clinical practice is still far from being achieved today owing to various constraints, such as limited accessibility of technology, inadequate knowledge, ambiguity of the role of variants and ethical concerns. 4. Drug actions are determined by the interplay of several genes encoding different proteins involved in various biochemical pathways. With rapidly emerging SNP discovery technological platforms and widespread knowledge on the role of SNPs in disease susceptibility and variability in drug response, the pharmacogenetics approach to therapeutics is anticipated to take off in the not-too-distant future. This will present profound clinical, economic and social implications for health care.

  3. Therapeutic nuclear medicine

    International Nuclear Information System (INIS)

    Baum, Richard P.

    2014-01-01

    Discusses all aspects of radionuclide therapy, including basic principles, newly available treatments, regulatory requirements, and future trends. Provides the knowledge required to administer radionuclide therapy safely and effectively in the individual patient. Explains the role of the therapeutic nuclear physician in effectively coordinating a diverse multidisciplinary team. Written by leading experts. The recent revolution in molecular biology offers exciting new opportunities for targeted radionuclide therapy. The selective irradiation of tumor cells through molecular biological mechanisms is now permitting the radiopharmaceutical control of tumors that are unresectable and unresponsive to either chemotherapy or conventional radiotherapy. In this up-to-date, comprehensive book, world-renowned experts discuss the basic principles of radionuclide therapy, explore in detail the available treatments, explain the regulatory requirements, and examine likely future developments. The full range of clinical applications is considered, including thyroid cancer, hematological malignancies, brain tumors, liver cancer, bone and joint disease, and neuroendocrine tumors. The combination of theoretical background and practical information will provide the reader with all the knowledge required to administer radionuclide therapy safely and effectively in the individual patient. Careful attention is also paid to the important role of the therapeutic nuclear physician in delivering the effective coordination of a diverse multidisciplinary team that is essential to the safe provision of treatment.

  4. Therapeutic nuclear medicine

    Energy Technology Data Exchange (ETDEWEB)

    Baum, Richard P. (ed.) [ENETS Center of Excellence, Bad Berka (Germany). THERANOSTICS Center for Molecular Radiotherapy and Molecular Imaging

    2014-07-01

    Discusses all aspects of radionuclide therapy, including basic principles, newly available treatments, regulatory requirements, and future trends. Provides the knowledge required to administer radionuclide therapy safely and effectively in the individual patient. Explains the role of the therapeutic nuclear physician in effectively coordinating a diverse multidisciplinary team. Written by leading experts. The recent revolution in molecular biology offers exciting new opportunities for targeted radionuclide therapy. The selective irradiation of tumor cells through molecular biological mechanisms is now permitting the radiopharmaceutical control of tumors that are unresectable and unresponsive to either chemotherapy or conventional radiotherapy. In this up-to-date, comprehensive book, world-renowned experts discuss the basic principles of radionuclide therapy, explore in detail the available treatments, explain the regulatory requirements, and examine likely future developments. The full range of clinical applications is considered, including thyroid cancer, hematological malignancies, brain tumors, liver cancer, bone and joint disease, and neuroendocrine tumors. The combination of theoretical background and practical information will provide the reader with all the knowledge required to administer radionuclide therapy safely and effectively in the individual patient. Careful attention is also paid to the important role of the therapeutic nuclear physician in delivering the effective coordination of a diverse multidisciplinary team that is essential to the safe provision of treatment.

  5. High-beta plasma blobs in the morningside plasma sheet

    Directory of Open Access Journals (Sweden)

    G. Haerendel

    Full Text Available Equator-S frequently encountered, i.e. on 30% of the orbits between 1 March and 17 April 1998, strong variations of the magnetic field strength of typically 5–15-min duration outside about 9RE during the late-night/early-morning hours. Very high-plasma beta values were found, varying between 1 and 10 or more. Close conjunctions between Equator-S and Geotail revealed the spatial structure of these "plasma blobs" and their lifetime. They are typically 5–10° wide in longitude and have an antisymmetric plasma or magnetic pressure distribution with respect to the equator, while being altogether low-latitude phenomena 
    (≤ 15°. They drift slowly sunward, exchange plasma across the equator and have a lifetime of at least 15–30 min. While their spatial structure may be due to some sort of mirror instability, little is known about the origin of the high-beta plasma. It is speculated that the morningside boundary layer somewhat further tailward may be the source of this plasma. This would be consistent with the preference of the plasma blobs to occur during quiet conditions, although they are also found during substorm periods. The relation to auroral phenomena in the morningside oval is uncertain. The energy deposition may be mostly too weak to generate a visible signature. However, patchy aurora remains a candidate for more disturbed periods.

    Key words. Magnetospheric physics (plasma convection; plasma sheet; plasma waves and instabilities

  6. Thermally stimulated scattering in plasmas

    DEFF Research Database (Denmark)

    Dysthe, K. B.; Mjølhus, E.; Pécseli, H. L.

    1985-01-01

    this experiment local heat conduction is of little importance and the dynamic evolution for the electron temperature is dominated by heating and energy exchange with the ion component. These features are incorporated in the analysis. The resulting set of equations gives a growth rate and characteristic scale size......A theory for stimulated scattering of a laser beam is formulated where the dominant nonlinearity is the ohmic heating of the plasma. The analysis is carried out with particular reference to experimental investigations of CO2 laser heating of linear discharge plasma. In the conditions characterizing...

  7. Analysis of the plasma sweeper

    International Nuclear Information System (INIS)

    Glanz, J.; Motley, R.W.

    1982-09-01

    The coupling of lower hybrid waves to a plasma can be modified by placing potentials on electrodes near the mouth of a phased array. Positive potentials on the electrodes create an electric field that sweeps the plasma away at a velocity c anti E x anti B/B 2 . In this paper we derive the electric field created by the applied potential from the nondivergent character of the current flow and the ion momentum equation, in which ion-neutral charge-exchange collisions are retained, and we compare the predictions with experimental data

  8. Sub therapeutic drug levels among HIV/TB co-infected patients ...

    African Journals Online (AJOL)

    Daniel W. Gunda

    2016-11-01

    Nov 1, 2016 ... NVP based regimen was associated with sub-therapeutic drug levels on uni- ... a number of important challenges including induction of sub- therapeutic levels of .... ARV plasma levels in the univariate model with p-values less than 0.05 .... clearance of ARVs.56 This may be one of the explanations that.

  9. Bridge between fusion plasma and plasma processing

    International Nuclear Information System (INIS)

    Ohno, Noriyasu; Takamura, Shuichi

    2008-01-01

    In the present review, relationship between fusion plasma and processing plasma is discussed. From boundary-plasma studies in fusion devices new applications such as high-density plasma sources, erosion of graphite in a hydrogen plasma, formation of helium bubbles in high-melting-point metals and the use of toroidal plasmas for plasma processing are emerging. The authors would like to discuss a possibility of knowledge transfer from fusion plasmas to processing plasmas. (T. Ikehata)

  10. Determination of aminopolycarboxylic acids at ultra-trace levels by means of online coupling ion exchange chromatography and inductively coupled plasma-mass spectrometry with indirect detection via their Pd2+-complexes

    International Nuclear Information System (INIS)

    Nette, David; Seubert, Andreas

    2015-01-01

    Highlights: • 8 important APCA’s analyzed in one run instead of 3 in the previous method. • Pd 2+ extents the methods applicability to 3 and more dentate amino carboxylic acids. • Separation system optimized for the isocratic determination of important APCA’s. • Thermodynamic stability of APCA–Pd 2+ complexes is higher than for Fe 3+ and In 3+ . • Pd 2+ is kinetically much slower than Fe 3+ and In 3+ and makes the method more rugged. - Abstract: A new indirect IC-ICP-MS method for the determination of aminopolycarboxylic acids in water samples is described. It is based on the addition of an excess of Pd(II) to water samples. The analytes are forced into very strong and negatively charged palladium complexes, separated by ion exchange chromatography and detected by their palladium content, utilizing an on-line coupled ICP-MS. This method is suitable to determine the concentration of 8 aminopolycarboxylic acids (nitrilotriacetic acid (NTA), (2-carboxyethyl) iminodiacetic acid (β-ADA), methylglycinediacetic acid (MGDA), 2-hydroxyethyl) ethylenediamine triacetic acid (HEDTA), diethylene triamine pentaacetic acid (DTPA), ethylendiamine tetraacetic acid (EDTA), 1,3-diaminopropane tetraacetic acid (1,3-PDTA) and 1,2-diaminopropane tetraacetic acid (1,2-PDTA) at the ng kg −1 level. The method is faster and easier than the established gas chromatography (GC)-method ISO 16588:2002 [1] and up to two orders of magnitude more sensitive than the ion pair chromatography based method of DIN 38413-8. Analytic performance is superior to ISO 16588:2002 and the comparability is good

  11. Determination of aminopolycarboxylic acids at ultra-trace levels by means of online coupling ion exchange chromatography and inductively coupled plasma-mass spectrometry with indirect detection via their Pd{sup 2+}-complexes

    Energy Technology Data Exchange (ETDEWEB)

    Nette, David; Seubert, Andreas, E-mail: seubert@staff.uni-marburg.de

    2015-07-16

    Highlights: • 8 important APCA’s analyzed in one run instead of 3 in the previous method. • Pd{sup 2+} extents the methods applicability to 3 and more dentate amino carboxylic acids. • Separation system optimized for the isocratic determination of important APCA’s. • Thermodynamic stability of APCA–Pd{sup 2+} complexes is higher than for Fe{sup 3+} and In{sup 3+}. • Pd{sup 2+} is kinetically much slower than Fe{sup 3+} and In{sup 3+} and makes the method more rugged. - Abstract: A new indirect IC-ICP-MS method for the determination of aminopolycarboxylic acids in water samples is described. It is based on the addition of an excess of Pd(II) to water samples. The analytes are forced into very strong and negatively charged palladium complexes, separated by ion exchange chromatography and detected by their palladium content, utilizing an on-line coupled ICP-MS. This method is suitable to determine the concentration of 8 aminopolycarboxylic acids (nitrilotriacetic acid (NTA), (2-carboxyethyl) iminodiacetic acid (β-ADA), methylglycinediacetic acid (MGDA), 2-hydroxyethyl) ethylenediamine triacetic acid (HEDTA), diethylene triamine pentaacetic acid (DTPA), ethylendiamine tetraacetic acid (EDTA), 1,3-diaminopropane tetraacetic acid (1,3-PDTA) and 1,2-diaminopropane tetraacetic acid (1,2-PDTA) at the ng kg{sup −1} level. The method is faster and easier than the established gas chromatography (GC)-method ISO 16588:2002 [1] and up to two orders of magnitude more sensitive than the ion pair chromatography based method of DIN 38413-8. Analytic performance is superior to ISO 16588:2002 and the comparability is good.

  12. Optimization of an anion-exchange high performance liquid chromatography-inductively coupled plasma-mass spectrometric method for the speciation analysis of oxyanion-forming metals and metalloids in leachates from cement-based materials.

    Science.gov (United States)

    Mulugeta, Mesay; Wibetoe, Grethe; Engelsen, Christian J; Lund, Walter

    2010-10-01

    A method was developed for the speciation analysis of the oxyanions of As(III), As(V), Cr(VI), Mo(VI), Sb(III), Sb(V), Se(IV), Se(VI) and V(V) in leachates from cement-based materials, based on anion-exchange HPLC coupled with ICP-MS. The method was optimized in a two-step multivariate approach: the effect of sample pH and mobile phase composition on resolution, peak symmetry and analysis time was studied. Optimum conditions were then identified for the significant experimental factors by studying their interdependence. A mobile phase composition of 20 mM ammonium nitrate, 50 mM ammonium tartrate and pH 9.5 was found to be a compromise optimum for the separation of the target analytes using isocratic elution. The optimum condition provided separation of the analytes in less than 6 min, at a mobile phase flow rate of 1.0 mL/min. The signal intensities of the analytes were improved by adding 1% methanol to the mobile phase. The limit of detection of the method was in the range 0.2-2.2 μg/L for the various species. The effect of sample constituents was studied using spiked concrete leachates. The method was used to determine the target oxyanionic species in leachates generated from a concrete material in the pH range 3.5-12.4; CrO(4)(2-), MoO(4)(2-) and VO(4)(3-) were detected in most of the leachates. Copyright © 2010 Elsevier B.V. All rights reserved.

  13. Plasma waves

    National Research Council Canada - National Science Library

    Swanson, D. G

    1989-01-01

    ... Swanson, D.G. (Donald Gary), D a t e - Plasma waves. Bibliography: p. Includes index. 1. Plasma waves. QC718.5.W3S43 1989 ISBN 0-12-678955-X I. Title. 530.4'4 88-34388 Printed in the United Sta...

  14. Plasma properties

    International Nuclear Information System (INIS)

    Weitzner, H.

    1991-06-01

    The Magneto-Fluid Dynamics Division continues to study a broad range of problems originating in plasma physics. Its principal focus is fusion plasma physics, and most particularly topics of particular significance for the world magnetic fusion program. During the calendar year 1990 we explored a wide range of topics including RF-induced transport as a plasma control mechanism, edge plasma modelling, further statistical analysis of L and H mode tokamak plasmas, antenna design, simulation of the edge of a tokamak plasma and the L-H transition, interpretation of the CCT experimental results at UCLA, turbulent transport, studies in chaos, the validity of moment approximations to kinetic equations and improved neoclassical modelling. In more basic studies we examined the statistical mechanisms of Coulomb systems and applied plasma ballooning mode theory to conventional fluids in order to obtain novel fluid dynamics stability results. In space plasma physics we examined the problem of reconnection, the effect of Alfven waves in space environments, and correct formulation of boundary conditions of the Earth for waves in the ionosphere

  15. Plasma container

    International Nuclear Information System (INIS)

    Ebisawa, Katsuyuki.

    1985-01-01

    Purpose: To enable to easily detect that the thickness of material to be abraded is reduced to an allowable limit from the outerside of the plasma container even during usual operation in a plasma vessel for a thermonuclear device. Constitution: A labelled material is disposed to the inside or rear face of constituent members of a plasma container undergoing the irradiation of plasma particles. A limiter plate to be abraded in the plasma container is composed of an armour member and heat removing plate, in which the armour member is made of graphite and heat-removing plate is made of copper. If the armour member is continuously abraded under the effect of sputtering due to plasma particles, silicon nitride embedded so far in the graphite at last appears on the surface of the limiter plate to undergo the impact shocks of the plasma particles. Accordingly, abrasion of the limiter material can be detected by a detector comprising gas chromatography and it can easily be detected from the outside of the plasma content even during normal operation. (Horiuchi, T.)

  16. Anion exchange membrane

    Science.gov (United States)

    Verkade, John G; Wadhwa, Kuldeep; Kong, Xueqian; Schmidt-Rohr, Klaus

    2013-05-07

    An anion exchange membrane and fuel cell incorporating the anion exchange membrane are detailed in which proazaphosphatrane and azaphosphatrane cations are covalently bonded to a sulfonated fluoropolymer support along with anionic counterions. A positive charge is dispersed in the aforementioned cations which are buried in the support to reduce the cation-anion interactions and increase the mobility of hydroxide ions, for example, across the membrane. The anion exchange membrane has the ability to operate at high temperatures and in highly alkaline environments with high conductivity and low resistance.

  17. Cosmic plasma

    Energy Technology Data Exchange (ETDEWEB)

    Alfven, H [California Univ., San Diego, La Jolla (USA)

    1981-01-01

    The properties of space plasmas are analyzed, based on laboratory results and data obtained by in situ measurements in the magnetosphere (including the heliosphere). Attention is given to the question of how much knowledge can be gained by a systematic comparison of different regions of plasma, and plasmas are considered with linear dimensions varying from laboratory size up to the Hubble distance. The traditional magnetic field description of plasmas is supplemented by an electric current description and it is demonstrated that many problems are easier to understand with a dualistic approach. Using the general plasma properties obtained, the origin and evolution of the solar system is summarized and the evolution and present structure of the universe (cosmology) is discussed.

  18. Plasma device

    International Nuclear Information System (INIS)

    Thode, L.E.

    1981-01-01

    A relativistic electron beam generator or accelerator produces a high-voltage electron beam which is modulated to initiate electron bunching within the beam which is then applied to a high-density target plasma which typically comprises DT, DD, or similar thermonuclear gas at a density of 10 17 to 10 20 electrons per cubic centimeter. As a result, relativistic streaming instabilities are initiated within the high-density target plasma causing the relativistic electron beam to efficiently deposit its energy into a small localized region of the high-density plasma target. The high-temperature plasma can be used to heat a high Z material to generate radiation. Alternatively, a tunable radiation source is produced by using a moderate Z gas or a mixture of high Z and low Z gas as the target plasma. (author)

  19. Designing plasmas for chronic wound disinfection

    International Nuclear Information System (INIS)

    Nosenko, T; Shimizu, T; Morfill, G E

    2009-01-01

    Irradiation with low-temperature atmospheric-pressure plasma provides a promising method for chronic wound disinfection. To be efficient for this purpose, plasma should meet the following criteria: it should significantly reduce bacterial density in the wounded area, cause a long-term post-irradiation inhibition of bacterial growth, yet without causing any negative effect on human cells. In order to design plasmas that would satisfy these requirements, we assessed the relative contribution of different components with respect to bactericidal properties due to irradiation with argon plasma. We demonstrate that plasma-generated UV radiation is the main short-term sterilizing factor of argon plasma. On the other hand, plasma-generated reactive nitrogen species (RNS) and reactive oxygen species (ROS) cause a long-term 'after-irradiation' inhibition of bacterial growth and, therefore, are important for preventing wound recolonization with bacteria between two treatments. We also demonstrate that at certain concentrations plasma-generated RNS and ROS cause significant reduction of bacterial density, but have no adverse effect on human skin cells. Possible mechanisms of the different effects of plasma-generated reactive species on bacteria and human cells are discussed. The results of this study suggest that argon plasma for therapeutic purposes should be optimized in the direction of reducing the intensity of plasma-generated UV radiation and increasing the density of non-UV plasma products.

  20. Designing plasmas for chronic wound disinfection

    Energy Technology Data Exchange (ETDEWEB)

    Nosenko, T; Shimizu, T; Morfill, G E [Max-Planck Institute for Extraterrestrial Physics, Garching (Germany)], E-mail: tnosenko@mpe.mpg.de

    2009-11-15

    Irradiation with low-temperature atmospheric-pressure plasma provides a promising method for chronic wound disinfection. To be efficient for this purpose, plasma should meet the following criteria: it should significantly reduce bacterial density in the wounded area, cause a long-term post-irradiation inhibition of bacterial growth, yet without causing any negative effect on human cells. In order to design plasmas that would satisfy these requirements, we assessed the relative contribution of different components with respect to bactericidal properties due to irradiation with argon plasma. We demonstrate that plasma-generated UV radiation is the main short-term sterilizing factor of argon plasma. On the other hand, plasma-generated reactive nitrogen species (RNS) and reactive oxygen species (ROS) cause a long-term 'after-irradiation' inhibition of bacterial growth and, therefore, are important for preventing wound recolonization with bacteria between two treatments. We also demonstrate that at certain concentrations plasma-generated RNS and ROS cause significant reduction of bacterial density, but have no adverse effect on human skin cells. Possible mechanisms of the different effects of plasma-generated reactive species on bacteria and human cells are discussed. The results of this study suggest that argon plasma for therapeutic purposes should be optimized in the direction of reducing the intensity of plasma-generated UV radiation and increasing the density of non-UV plasma products.

  1. Antibody Engineering and Therapeutics

    Science.gov (United States)

    Almagro, Juan Carlos; Gilliland, Gary L; Breden, Felix; Scott, Jamie K; Sok, Devin; Pauthner, Matthias; Reichert, Janice M; Helguera, Gustavo; Andrabi, Raiees; Mabry, Robert; Bléry, Mathieu; Voss, James E; Laurén, Juha; Abuqayyas, Lubna; Barghorn, Stefan; Ben-Jacob, Eshel; Crowe, James E; Huston, James S; Johnston, Stephen Albert; Krauland, Eric; Lund-Johansen, Fridtjof; Marasco, Wayne A; Parren, Paul WHI; Xu, Kai Y

    2014-01-01

    The 24th Antibody Engineering & Therapeutics meeting brought together a broad range of participants who were updated on the latest advances in antibody research and development. Organized by IBC Life Sciences, the gathering is the annual meeting of The Antibody Society, which serves as the scientific sponsor. Preconference workshops on 3D modeling and delineation of clonal lineages were featured, and the conference included sessions on a wide variety of topics relevant to researchers, including systems biology; antibody deep sequencing and repertoires; the effects of antibody gene variation and usage on antibody response; directed evolution; knowledge-based design; antibodies in a complex environment; polyreactive antibodies and polyspecificity; the interface between antibody therapy and cellular immunity in cancer; antibodies in cardiometabolic medicine; antibody pharmacokinetics, distribution and off-target toxicity; optimizing antibody formats for immunotherapy; polyclonals, oligoclonals and bispecifics; antibody discovery platforms; and antibody-drug conjugates. PMID:24589717

  2. Therapeutic and diagnostic nanomaterials

    CERN Document Server

    Devasena T

    2017-01-01

    This brief highlights nanoparticles used in the diagnosis and treatment of prominent diseases and toxic conditions. Ecofriendly methods which are ideal for the synthesis of medicinally valued nanoparticles are explained and the characteristic features of these particles projected. The role of these particles in the therapeutic field, and the induced biological changes in some diseases are discussed. The main focus is on inflammation, oxidative stress and cellular membrane integrity alterations. The effect of nanoparticles on these changes produced by various agents are highlighted using in vitro and in vivo models. The mechanism of nanoparticles in ameliorating the biological changes is supported by relevant images and data. Finally, the brief demonstrates recent developments on the use of nanoparticles in diagnosis or sensing of some biological materials and biologically hazardous environmental materials.

  3. [Therapeutic education didactic techniques].

    Science.gov (United States)

    Valverde, Maite; Vidal, Mercè; Jansa, Margarida

    2012-10-01

    This article includes an introduction to the role of Therapeutic Education for Diabetes treatment according to the recommendations of the American Diabetes Association (ADA), the Diabetes Education Study Group (DESG) of the "European Association for Study of Diabetes (EASD) and the clinical Practice Guidelines (CPG) of the Spanish Ministry of Health. We analyze theoretical models and the differences between teaching vs. learning as well as current trends (including Internet), that can facilitate meaningful learning of people with diabetes and their families and relatives. We analyze the differences, similarities, advantages and disadvantages of individual and group education. Finally, we describe different educational techniques (metaplan, case method, brainstorming, role playing, games, seminars, autobiography, forums, chats,..) applicable to individual, group or virtual education and its application depending on the learning objective.

  4. Superconducting plasmas

    International Nuclear Information System (INIS)

    Ohnuma, Toshiro; Ohno, J.

    1994-01-01

    Superconducting (SC) plasmas are proposed and investigated. The SC plasmas are not yet familiar and have not yet been studied. However, the existence and the importance of SC plasmas are stressed in this report. The existence of SC plasmas are found as follows. There is a fundamental property of Meissner effect in superconductors, which shows a repulsive effect of magnetic fields. Even in that case, in a microscopic view, there is a region of magnetic penetration. The penetration length λ is well-known as London's penetration depth, which is expressed as δ = (m s /μ 0 n s q s 2 ) 1/2 where m s , n s , q s and μ o show the mass, the density, the charge of SC electron and the permeability in free space, respectively. Because this expression is very simple, no one had tried it into more simple and meaningful form. Recently, one of the authors (T.O.) has found that the length can be expressed into more simple and understandable fundamental form as λ = c/ω ps where c = (ε 0 μ 0 ) -1/2 and ω ps = (n s q s 2 /m s ε 0 ) 1/2 are the light velocity and the superconducting plasma frequency. From this simple expression, the penetration depth of the magnetic field to SC is found as a SC plasma skin depth, that is, the fundamental property of SC can be expressed by the SC plasmas. This discovery indicates an importance of the studies of superconducting plasmas. From these points, several properties (propagating modes et al) of SC plasmas, which consist of SC electrons, normal electrons and lattice ions, are investigated in this report. Observations of SC plasma frequency is also reported with a use of Terahertz electromagnet-optical waves

  5. Data Exchange Inventory System (DEXI)

    Data.gov (United States)

    Social Security Administration — Enterprise tool used to identify data exchanges occurring between SSA and our trading partners. DEXI contains information on both incoming and outgoing exchanges and...

  6. Pion double charge exchange

    International Nuclear Information System (INIS)

    Cooper, M.D.

    1978-01-01

    The pion double charge exchange data on the oxygen isotopes is reviewed and new data on 9 Be, 12 C, 24 Mg, and 28 Si are presented. Where theoretical calculations exist, they are compared to the data. 9 references

  7. Research peer exchange, 2014.

    Science.gov (United States)

    2017-08-01

    The WSDOT Research Peer Exchange was held in Olympia, Washington on May 13 and 14, 2014 and addressed Research Program and Project Management as described in the following paragraphs: Program Management There are numerous funding programs, standing c...

  8. Cation Exchange Water Softeners

    Science.gov (United States)

    WaterSense released a notice of intent to develop a specification for cation exchange water softeners. The program has made the decision not to move forward with a spec at this time, but is making this information available.

  9. Exchange Risk Management Policy

    CERN Document Server

    2005-01-01

    At the Finance Committee of March 2005, following a comment by the CERN Audit Committee, the Chairman invited the Management to prepare a document on exchange risk management policy. The Finance Committee is invited to take note of this document.

  10. HUD Exchange Grantee Database

    Data.gov (United States)

    Department of Housing and Urban Development — The About Grantees section of the HUD Exchange brings up contact information, reports, award, jurisdiction, and location data for organizations that receive HUD...

  11. NASA Earth Exchange (NEX)

    Data.gov (United States)

    National Aeronautics and Space Administration — The NASA Earth Exchange (NEX) represents a new platform for the Earth science community that provides a mechanism for scientific collaboration and knowledge sharing....

  12. Anti-N-methyl-D-aspartate receptor encephalitis after Herpes simplex virus-associated encephalitis: an emerging disease with diagnosis and therapeutic challenges.

    Science.gov (United States)

    Schein, Flora; Gagneux-Brunon, Amandine; Antoine, Jean-Christophe; Lavernhe, Sylvie; Pillet, Sylvie; Paul, Stéphane; Frésard, Anne; Boutet, Claire; Grange, Rémi; Cazorla, Céline; Lucht, Frédéric; Botelho-Nevers, Elisabeth

    2017-08-01

    Morbidity and mortality of Herpes simplex virus encephalitis (HSE) remain high. Relapses of neurological signs may occur after initial clinical improvement under acyclovir treatment. We report here a case of post-HSE anti-N-methyl-d-aspartate receptor-mediated encephalitis in an adult and perform a systematic search on PubMed to identify other cases in adults. We identified 11 previously published cases, to discuss diagnostic and therapeutic management. Symptoms in adults are often inappropriate behaviors, confusion and agitation. Diagnosis of anti-NMDA-R encephalitis after HSE is often delayed. Treatment consists in steroids, plasma exchange, and rituximab. Prognosis is often favorable. Anti-NMDA-R antibodies should be searched in cerebrospinal fluid of patients with unexpected evolution of HSE. This emerging entity reopens the hot debate about steroids in HSE.

  13. Floating Exchange Rate Regime

    OpenAIRE

    Quader, Syed Manzur

    2004-01-01

    In recent years, many developing countries having a history of high inflation, unfavorable balance of payment situation and a high level of foreign currencies denominated debt, have switched or are in the process of switching to a more flexible exchange rate regime. Therefore, the stability of the exchange rate and the dynamics of its volatility are more crucial than before to prevent financial crises and macroeconomic disturbances. This paper is designed to find out the reasons behind Bangla...

  14. Heat exchange apparatus

    International Nuclear Information System (INIS)

    Thurston, G.C.; McDaniels, J.D.; Gertsch, P.R.

    1979-01-01

    The present invention relates to heat exchangers used for transferring heat from the gas cooled core of a nuclear reactor to a secondary medium during standby and emergency conditions. The construction of the heat exchanger described is such that there is a minimum of welds exposed to the reactor coolant, the parasitic heat loss during normal operation of the reactor is minimized and the welds and heat transfer tubes are easily inspectable. (UK)

  15. Hibernation and gas exchange.

    Science.gov (United States)

    Milsom, William K; Jackson, Donald C

    2011-01-01

    Hibernation in endotherms and ectotherms is characterized by an energy-conserving metabolic depression due to low body temperatures and poorly understood temperature-independent mechanisms. Rates of gas exchange are correspondly reduced. In hibernating mammals, ventilation falls even more than metabolic rate leading to a relative respiratory acidosis that may contribute to metabolic depression. Breathing in some mammals becomes episodic and in some small mammals significant apneic gas exchange may occur by passive diffusion via airways or skin. In ectothermic vertebrates, extrapulmonary gas exchange predominates and in reptiles and amphibians hibernating underwater accounts for all gas exchange. In aerated water diffusive exchange permits amphibians and many species of turtles to remain fully aerobic, but hypoxic conditions can challenge many of these animals. Oxygen uptake into blood in both endotherms and ectotherms is enhanced by increased affinity of hemoglobin for O₂ at low temperature. Regulation of gas exchange in hibernating mammals is predominately linked to CO₂/pH, and in episodic breathers, control is principally directed at the duration of the apneic period. Control in submerged hibernating ectotherms is poorly understood, although skin-diffusing capacity may increase under hypoxic conditions. In aerated water blood pH of frogs and turtles either adheres to alphastat regulation (pH ∼8.0) or may even exhibit respiratory alkalosis. Arousal in hibernating mammals leads to restoration of euthermic temperature, metabolic rate, and gas exchange and occurs periodically even as ambient temperatures remain low, whereas body temperature, metabolic rate, and gas exchange of hibernating ectotherms are tightly linked to ambient temperature. © 2011 American Physiological Society.

  16. Real exchange rate misalignments

    OpenAIRE

    Terra, Maria Cristina T.; Valladares, Frederico Estrella Carneiro

    2003-01-01

    This paper characterizes episodes of real appreciations and depreciations for a sample of 85 countries, approximately from 1960 to 1998. First, the equilibrium real exchange rate series are constructed for each country using Goldfajn and Valdes (1999) methodology (cointegration with fundamentals). Then, departures from equilibrium real exchange rate (misalignments) are obtained, and a Markov Switching Model is used to characterize the misalignments series as stochastic autor...

  17. Heat exchanger cleaning

    International Nuclear Information System (INIS)

    Gatewood, J.R.

    1980-01-01

    A survey covers the various types of heat-exchange equipment that is cleaned routinely in fossil-fired generating plants, the hydrocarbon-processing industry, pulp and paper mills, and other industries; the various types, sources, and adverse effects of deposits in heat-exchange equipment; some details of the actual procedures for high-pressure water jetting and chemical cleaning of some specific pieces of equipment, including nuclear steam generators. (DN)

  18. Plasma universe

    International Nuclear Information System (INIS)

    Alfven, H.

    1986-04-01

    Traditionally the views in our cosmic environment have been based on observations in the visual octave of the electromagnetic spectrum, during the last half-century supplemented by infrared and radio observations. Space research has opened the full spectrum. Of special importance are the X-ray-gamma-ray regions, in which a number of unexpected phenomena have been discovered. Radiations in these regions are likely to originate mainly from magnetised cosmic plasma. Such a medium may also emit synchrotron radiation which is observable in the radio region. If we try to base a model of the universe on the plasma phenomena mentioned we find that the plasma universe is drastically different from the traditional visual universe. Information about the plasma universe can also be obtained by extrapolation of laboratory experiments and magnetospheric in situ measurements of plasma. This approach is possible because it is likely that the basic properties of plasma are the same everywhere. In order to test the usefulness of the plasma universe model we apply it to cosmogony. Such an approach seems to be rather successful. For example, the complicated structure of the Saturnian C ring can be accounted for. It is possible to reconstruct certain phenomena 4-5 bilions years ago with an accuracy of better than 1 percent

  19. Cryptographic Combinatorial Securities Exchanges

    Science.gov (United States)

    Thorpe, Christopher; Parkes, David C.

    We present a useful new mechanism that facilitates the atomic exchange of many large baskets of securities in a combinatorial exchange. Cryptography prevents information about the securities in the baskets from being exploited, enhancing trust. Our exchange offers institutions who wish to trade large positions a new alternative to existing methods of block trading: they can reduce transaction costs by taking advantage of other institutions’ available liquidity, while third party liquidity providers guarantee execution—preserving their desired portfolio composition at all times. In our exchange, institutions submit encrypted orders which are crossed, leaving a “remainder”. The exchange proves facts about the portfolio risk of this remainder to third party liquidity providers without revealing the securities in the remainder, the knowledge of which could also be exploited. The third parties learn either (depending on the setting) the portfolio risk parameters of the remainder itself, or how their own portfolio risk would change if they were to incorporate the remainder into a portfolio they submit. In one setting, these third parties submit bids on the commission, and the winner supplies necessary liquidity for the entire exchange to clear. This guaranteed clearing, coupled with external price discovery from the primary markets for the securities, sidesteps difficult combinatorial optimization problems. This latter method of proving how taking on the remainder would change risk parameters of one’s own portfolio, without revealing the remainder’s contents or its own risk parameters, is a useful protocol of independent interest.

  20. Radial flow heat exchanger

    Science.gov (United States)

    Valenzuela, Javier

    2001-01-01

    A radial flow heat exchanger (20) having a plurality of first passages (24) for transporting a first fluid (25) and a plurality of second passages (26) for transporting a second fluid (27). The first and second passages are arranged in stacked, alternating relationship, are separated from one another by relatively thin plates (30) and (32), and surround a central axis (22). The thickness of the first and second passages are selected so that the first and second fluids, respectively, are transported with laminar flow through the passages. To enhance thermal energy transfer between first and second passages, the latter are arranged so each first passage is in thermal communication with an associated second passage along substantially its entire length, and vice versa with respect to the second passages. The heat exchangers may be stacked to achieve a modular heat exchange assembly (300). Certain heat exchangers in the assembly may be designed slightly differently than other heat exchangers to address changes in fluid properties during transport through the heat exchanger, so as to enhance overall thermal effectiveness of the assembly.

  1. Heating of toroidal plasmas by neutral injection

    International Nuclear Information System (INIS)

    Stix, T.H.

    1971-08-01

    This paper presents a brief review of the physics of ion acceleration, charge exchange and ionization, trajectories for fast ions in toroidal magnetic fields, and fast-ion thermalization. The injection of fast atoms is found to be a highly competitive method both for heating present-day experimental toroidal plasmas and for bringing full-scale toroidal CTR plasmas to low-density ignition. 13 refs., 9 figs

  2. Plasma physics

    International Nuclear Information System (INIS)

    1979-01-01

    This report contains the papers delivered at the AEB - Natal University summer school on plasma physics held in Durban during January 1979. The following topics were discussed: Tokamak devices; MHD stability; trapped particles in tori; Tokamak results and experiments; operating regime of the AEB Tokamak; Tokamak equilibrium; high beta Tokamak equilibria; ideal Tokamak stability; resistive MHD instabilities; Tokamak diagnostics; Tokamak control and data acquisition; feedback control of Tokamaks; heating and refuelling; neutral beam injection; radio frequency heating; nonlinear drift wave induced plasma transport; toroidal plasma boundary layers; microinstabilities and injected beams and quasilinear theory of the ion acoustic instability

  3. Plasma centrifuge

    International Nuclear Information System (INIS)

    Ikehata, Takashi; Mase, Hiroshi

    1998-01-01

    The plasma centrifuge is one of statistical isotope separation processes which uses the centrifugal force of a J x B driven rotating plasma in a magnetic field to give rise to the mass-dependent radial transport of isotopic ions. The system has been developed as an alternative to the gas centrifuge because a much higher rotational velocity and separation factor have been achieved. In this review, the physical aspects of the plasma centrifuge followed by the recent experimental achievements are described, especially in comparison with the gas centrifuge. (author)

  4. 2. Basis of measurement of plasma flow. 2.3 Plasma flow measurements. Spectroscopic methods

    International Nuclear Information System (INIS)

    Kado, Shinichiro

    2007-01-01

    The construction of optical system, optical fiber incident system, reciprocal linear dispersion, grating smile and astigmatism of the reflection plane diffraction grating spectrometer are explained in order to measure the plasma flow. The specification of flow measurement and evaluation of 0 point of velocity are stated. For examples of measurements, the fine structures of He II (Δn = 3 - 4) in material and plasma(MAP)-II of Tokyo University, plasma flow measurement by the charge exchange recombination spectroscopy using Large Helical Device and by Zeeman spectroscopy using TRIAM-1M tokamak plasma are stated. (S.Y.)

  5. [Nuclear transfer and therapeutic cloning].

    Science.gov (United States)

    Xu, Xiao-Ming; Lei, An-Min; Hua, Jin-Lian; Dou, Zhong-Ying

    2005-03-01

    Nuclear transfer and therapeutic cloning have widespread and attractive prospects in animal agriculture and biomedical applications. We reviewed that the quality of oocytes and nuclear reprogramming of somatic donor cells were the main reasons of the common abnormalities in cloned animals and the low efficiency of cloning and showed the problems and outlets in therapeutic cloning, such as some basic problems in nuclear transfer affected clinical applications of therapeutic cloning. Study on isolation and culture of nuclear transfer embryonic stem (ntES) cells and specific differentiation of ntES cells into important functional cells should be emphasized and could enhance the efficiency. Adult stem cells could help to cure some great diseases, but could not replace therapeutic cloning. Ethics also impeded the development of therapeutic cloning. It is necessary to improve many techniques and reinforce the research of some basic theories, then somatic nuclear transfer and therapeutic cloning may apply to agriculture reproduction and benefit to human life better.

  6. Charge exchange emission from solar wind helium ions

    NARCIS (Netherlands)

    Bodewits, D; Hoekstra, R; Seredyuk, B; McCullough, RW; Jones, GH; Tielens, AGGM

    2006-01-01

    Charge exchange X-ray and far-ultraviolet (FUV) aurorae can provide detailed insight into the interaction between solar system plasmas. Using the two complementary experimental techniques of photon emission spectroscopy and translation energy spectroscopy, we have studied state-selective charge

  7. Molecularly targeted therapeutic radiopharmaceuticals

    International Nuclear Information System (INIS)

    Saw, M.M.

    2007-01-01

    Full text: It is generally agreed that current focus of nuclear medicine development should be on molecular imaging and therapy. Though, the widespread use of the terminology 'molecular imaging' is quite recent, nuclear medicine has used molecular imaging techniques for more than 20 years ago. A variety of radiopharmaceuticals have been introduced for the internal therapy of malignant and inflammatory lesions in nuclear medicine. In the field of bio/medical imaging, nuclear medicine is one of the disciplines which has the privilege of organized and well developed chemistry/ pharmacy section; radio-chemistry/radiopharmacy. Fundamental principles have been developed more than 40 years ago and advanced research is going well into postgenomic era. The genomic revolution and dramatically increased insight in the molecular mechanisms underlying pathology have led to paradigm shift in drug development. Likewise does in the nuclear medicine. Here, the author will present current clinical and pre-clinical therapeutic radiopharmaceuticals based on molecular targets such as membrane-bound receptors, enzymes, nucleic acids, sodium iodide symporter, etc, in correlation with fundamentals of radiopharmacy. (author)

  8. Plasma Cleaning

    Science.gov (United States)

    Hintze, Paul E.

    2016-01-01

    NASA's Kennedy Space Center has developed two solvent-free precision cleaning techniques: plasma cleaning and supercritical carbon dioxide (SCCO2), that has equal performance, cost parity, and no environmental liability, as compared to existing solvent cleaning methods.

  9. Laser Plasmas

    Indian Academy of Sciences (India)

    -focusing in a plasma ... Center for Energy Studies, Indian Institute of Technology, New Delhi 110 016, India; Tata Consultancy Services, Gurgaon, India; Ideal Institute of Technology, Ghaziabad, India; Center for Research in Cognitive, ...

  10. Plasma will…

    Czech Academy of Sciences Publication Activity Database

    Lunov, Oleg

    2016-01-01

    Roč. 174, č. 3 (2016), s. 486-487 ISSN 0007-0963 Institutional support: RVO:68378271 Keywords : plasma * ionized gas Subject RIV: BO - Biophysics OBOR OECD: Biophysics Impact factor: 4.706, year: 2016

  11. Plasma technology

    International Nuclear Information System (INIS)

    Drouet, M.G.

    1984-03-01

    IREQ was contracted by the Canadian Electrical Association to review plasma technology and assess the potential for application of this technology in Canada. A team of experts in the various aspects of this technology was assembled and each team member was asked to contribute to this report on the applications of plasma pertinent to his or her particular field of expertise. The following areas were examined in detail: iron, steel and strategic-metals production; surface treatment by spraying; welding and cutting; chemical processing; drying; and low-temperature treatment. A large market for the penetration of electricity has been identified. To build up confidence in the technology, support should be provided for selected R and D projects, plasma torch demonstrations at full power, and large-scale plasma process testing

  12. Therapeutically targeting mitochondrial redox signalling alleviates endothelial dysfunction in preeclampsia.

    Science.gov (United States)

    McCarthy, Cathal; Kenny, Louise C

    2016-09-08

    Aberrant placentation generating placental oxidative stress is proposed to play a critical role in the pathophysiology of preeclampsia. Unfortunately, therapeutic trials of antioxidants have been uniformly disappointing. There is provisional evidence implicating mitochondrial dysfunction as a source of oxidative stress in preeclampsia. Here we provide evidence that mitochondrial reactive oxygen species mediates endothelial dysfunction and establish that directly targeting mitochondrial scavenging may provide a protective role. Human umbilical vein endothelial cells exposed to 3% plasma from women with pregnancies complicated by preeclampsia resulted in a significant decrease in mitochondrial function with a subsequent significant increase in mitochondrial superoxide generation compared to cells exposed to plasma from women with uncomplicated pregnancies. Real-time PCR analysis showed increased expression of inflammatory markers TNF-α, TLR-9 and ICAM-1 respectively in endothelial cells treated with preeclampsia plasma. MitoTempo is a mitochondrial-targeted antioxidant, pre-treatment of cells with MitoTempo protected against hydrogen peroxide-induced cell death. Furthermore MitoTempo significantly reduced mitochondrial superoxide production in cells exposed to preeclampsia plasma by normalising mitochondrial metabolism. MitoTempo significantly altered the inflammatory profile of plasma treated cells. These novel data support a functional role for mitochondrial redox signaling in modulating the pathogenesis of preeclampsia and identifies mitochondrial-targeted antioxidants as potential therapeutic candidates.

  13. Rethinking Therapeutic Misconception in Biobanking

    DEFF Research Database (Denmark)

    Tupasela, Aaro; Snell, Karoliina; Cañada, Jose

    2017-01-01

    Some authors have noted that in biobank research participants may be guided by what is called therapeutic misconception, whereby participants attribute therapeutic intent to research procedures.This article argues that the notion of therapeutic misconception is increasingly less justified when...... underpinnings for the need to separate research and treatment, and thus the notion of therapeutic misconception in the fi rst place. We call this tension between research and treatment ambivalent research advancement to highlight the difficulties that various actors have in managing such shifts within...

  14. Therapeutic cloning: The ethical limits

    International Nuclear Information System (INIS)

    Whittaker, Peter A.

    2005-01-01

    A brief outline of stem cells, stem cell therapy and therapeutic cloning is given. The position of therapeutic cloning with regard to other embryonic manipulations - IVF-based reproduction, embryonic stem formation from IVF embryos and reproductive cloning - is indicated. The main ethically challenging stages in therapeutic cloning are considered to be the nuclear transfer process including the source of eggs for this and the destruction of an embryo to provide stem cells for therapeutic use. The extremely polarised nature of the debate regarding the status of an early human embryo is noted, and some potential alternative strategies for preparing immunocompatible pluripotent stem cells are indicated

  15. Therapeutic cloning in the mouse

    Science.gov (United States)

    Mombaerts, Peter

    2003-01-01

    Nuclear transfer technology can be applied to produce autologous differentiated cells for therapeutic purposes, a concept termed therapeutic cloning. Countless articles have been published on the ethics and politics of human therapeutic cloning, reflecting the high expectations from this new opportunity for rejuvenation of the aging or diseased body. Yet the research literature on therapeutic cloning, strictly speaking, is comprised of only four articles, all in the mouse. The efficiency of derivation of embryonic stem cell lines via nuclear transfer is remarkably consistent among these reports. However, the efficiency is so low that, in its present form, the concept is unlikely to become widespread in clinical practice. PMID:12949262

  16. Therapeutic Plasmapheresis. A Gate to an Effective Treatment of Severe Pathological Conditions

    Directory of Open Access Journals (Sweden)

    Claudia Stefanutti

    2014-07-01

        Table 1. Different clinical use of conventional and selective apheresis techniques in relation to the pathology to be treated in emergency or on long (chronic-term.  Throughout the acute phase of hyperlipidemic pancreatitis (HLP, PEX (Lipid-apheresis could be of considerable assistance not only in lowering TG levels but also in the prevention of recurrent HLP (3. Furthermore, patients with homo-, double- compound-, and heterozygous Familial Hypercholesterolemia and HyperLp(a lipoproteinemia would benefit lipoprotein-apheresis (LA as an extracorporeal procedure providing selective removal of lipids and lipoproteins including Low Density Lipoproteins (LDL and other apolipoprotein B100-containing lipoproteins (4, 5. Having numerous metabolic and clinical superiorities, LA characterizes an upgraded selective form of conventional extracorporeal therapies, e.g. plasma-exchange (PEX- Lipid-apheresis, which were broadly-used for managing severe hypercholesterolemia in the seventies. However, LA is primarily used in the treatment of previously-mentioned severe forms of dyslipidemia. FH patients are particularly prone to coronary ischemic events necessitating a tailored, intensive, efficient, continuous, and unceasing form of treatment. Obviously, a therapeutic approach exclusively relying on existing accessible medications would not lead to preferred clinical outcomes. The above reported clinical examples clearly suggest what differences exist between the non-selective and selective apheresis techniques as far as different pathologies exhibiting affinity are concerned. In particular, the clinical presentation, emergency or not, greatly affects the use of a given extracorporeal technique. However, depending upon the indication, a selective technique not usually utilized in emergency, such as selective dextran sulfate cellulose LA was recently suggested to treat acutely preeclampsia, where targeted therapies to stabilize the clinical manifestations and prolong

  17. Plasma metallization

    International Nuclear Information System (INIS)

    Crowther, J.M.

    1997-09-01

    Many methods are currently used for the production of thin metal films. However, all of these have drawbacks associated with them, for example the need for UHV conditions, high temperatures, exotic metal precursors, or the inability to coat complex shaped objects. Reduction of supported metal salts by non-isothermal plasma treatment does not suffer from these drawbacks. In order to produce and analyse metal films before they become contaminated, a plasma chamber which could be attached directly to a UHV chamber with XPS capability was designed and built. This allowed plasma treatment of supported metal salts and surface analysis by XPS to be performed without exposure of the metal film to the atmosphere. Non-equilibrium plasma treatment of Nylon 66 supported gold(lll) chloride using hydrogen as the feed gas resulted in a 95% pure gold film, the remaining 5% of the film being carbon. If argon or helium were used as the feed gases during plasma treatment the resultant gold films were 100% pure. Some degree of surface contamination of the films due to plasma treatment was observed but was easily removed by argon ion cleaning. Hydrogen plasma reduction of glass supported silver(l) nitrate and palladium(ll) acetate films reveals that this metallization technique is applicable to a wide variety of metal salts and supports, and has also shown the ability of plasma reduction to retain the complex 'fern-like' structures seen for spin coated silver(l) nitrate layers. Some metal salts are susceptible to decomposition by X-rays. The reduction of Nylon 66 supported gold(lll) chloride films by soft X-rays to produce nanoscopic gold particles has been studied. The spontaneous reduction of these X-ray irradiated support gold(lll) chloride films on exposure to the atmosphere to produce gold rich metallic films has also been reported. (author)

  18. Plasma confinement

    CERN Document Server

    Hazeltine, R D

    2003-01-01

    Detailed and authoritative, this volume examines the essential physics underlying international research in magnetic confinement fusion. It offers readable, thorough accounts of the fundamental concepts behind methods of confining plasma at or near thermonuclear conditions. Designed for a one- or two-semester graduate-level course in plasma physics, it also represents a valuable reference for professional physicists in controlled fusion and related disciplines.

  19. Plasma Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Zaveryaev, V [Kurchatov Institute, Moscow (Russian Federation); others, and

    2012-09-15

    The success in achieving peaceful fusion power depends on the ability to control a high temperature plasma, which is an object with unique properties, possibly the most complicated object created by humans. Over years of fusion research a new branch of science has been created, namely plasma diagnostics, which involves knowledge of almost all fields of physics, from electromagnetism to nuclear physics, and up-to-date progress in engineering and technology (materials, electronics, mathematical methods of data treatment). Historically, work on controlled fusion started with pulsed systems and accordingly the methods of plasma parameter measurement were first developed for short lived and dense plasmas. Magnetically confined hot plasmas require the creation of special experimental techniques for diagnostics. The diagnostic set is the most scientifically intensive part of a plasma device. During many years of research operation some scientific tasks have been solved while new ones arose. New tasks often require significant changes in the diagnostic system, which is thus a very flexible part of plasma machines. Diagnostic systems are designed to solve several tasks. As an example here are the diagnostic tasks for the International Thermonuclear Experimental Reactor - ITER: (1) Measurements for machine protection and basic control; (2) Measurements for advanced control; (3) Additional measurements for performance evaluation and physics. Every new plasma machine is a further step along the path to the main goal - controlled fusion - and nobody knows in advance what new phenomena will be met on the way. So in the planning of diagnostic construction we should keep in mind further system upgrading to meet possible new scientific and technical challenges. (author)

  20. Tensor exchange amplitudes in K +- N charge exchange reactions

    International Nuclear Information System (INIS)

    Svec, M.

    1979-01-01

    Tensor (A 2 ) exchange amplitudes in K +- N charge exchange (CEX) are constructed from the K +- N CEX data supplemented by information on the vector (rho) exchange amplitudes from πN sca tering. We observed new features in the t-structure of A 2 exchange amplitudes which contradict the t-de pendence anticipated by most of the Regge models. The results also provide evidence for violation of weak exchange degeneracy

  1. Characteristics of solid-target charge-exchange analyzers for energetic ion diagnostics on tokamaks

    International Nuclear Information System (INIS)

    Beiersdorfer, P.; Roquemore, A.L.; Kaita, R.

    1987-05-01

    Compact electrostatic charge-exchange analyzers have been constructed for installation in areas of high magnetic fields and restricted access near tokamak fusion devices. The analyzers employed carbon stripping foils, and have been calibrated for proton energies between 1 and 70 keV. They have been successfully used to study charge-exchange losses in auxiliary-heated tokamak plasmas

  2. Exchanging Description Logic Knowledge Bases

    NARCIS (Netherlands)

    Arenas, M.; Botoeva, E.; Calvanese, D.; Ryzhikov, V.; Sherkhonov, E.

    2012-01-01

    In this paper, we study the problem of exchanging knowledge between a source and a target knowledge base (KB), connected through mappings. Differently from the traditional database exchange setting, which considers only the exchange of data, we are interested in exchanging implicit knowledge. As

  3. Social dilemmas as exchange dilemmas

    NARCIS (Netherlands)

    Dijkstra, Jacob; van Assen, Marcel A.L.M.

    2016-01-01

    We develop a new paradigm to study social dilemmas, called exchange dilemmas. Exchange dilemmas arise from externalities of exchanges with third parties, and many real-life social dilemmas are more accurately modeled as exchange dilemmas rather than prisoner's dilemmas. Building on focusing and

  4. Social dilemmas as exchange dilemmas

    NARCIS (Netherlands)

    Dijkstra, J.; van Assen, M.A.L.M.

    2016-01-01

    We develop a new paradigm to study social dilemmas, called exchange dilemmas. Exchange dilemmas arise from externalities of exchanges with third parties, and many real-life social dilemmas are more accurately modeled as exchange dilemmas rather than prisoner's dilemmas. Bulding on focusing and

  5. Heat exchanger restart evaluation

    International Nuclear Information System (INIS)

    Morrison, J.M.; Hirst, C.W.; Lentz, T.F.

    1992-01-01

    On December 24, 1991, the K-Reactor was in the shutdown mode with full AC process water flow and full cooling water flow. Safety rod testing was being performed as part of the power ascension testing program. The results of cooling water samples indicated tritium concentrations higher than allowable. Further sampling and testing confirmed a Process Water System to Cooling Water System leak in heat exchanger 4A (HX 4A). The heat exchanger was isolated and the plant shutdown. Heat exchanger 4A was removed from the plant and moved to C-Area prior to performing examinations and diagnostic testing. This included locating and identifying the leaking tube or tubes, eddy current examination of the leaking tube and a number of adjacent tubes, visually inspecting the leaking tube from both the inside as well as the area surrounding the identified tube. The leaking tube was removed and examined metallurgically to determine the failure mechanism. In addition ten other tubes that either exhibited eddy current indications or would represent a baseline condition were removed from heat exchanger 4A for metallurgical examination. Additional analysis and review of heat exchanger leakage history was performed to determine if there are any patterns which can be used for predictive purposes. Compensatory actions have been taken to improve the sensitivity and response time to any future events of this type. The results of these actions are summary herein

  6. Heat exchanger restart evaluation

    International Nuclear Information System (INIS)

    Morrison, J.M.; Hirst, C.W.; Lentz, T.F.

    1992-01-01

    On December 24, 1991, the K-Reactor was in the shutdown mode with full AC process water flow and full cooling water flow. Safety rod testing was being performed as part of the power ascension testing program. The results of cooling water samples indicated tritium concentrations higher than allowable. Further sampling and testing confirmed a Process Water System to Cooling Water System leak in heat exchanger 4A (HX 4A). The heat exchanger was isolated and the plant shutdown. Heat exchanger 4kA was removed from the plant and moved to C-Area prior to performing examinations and diagnostic testing. This included locating and identifying the leaking tube or tubes, eddy current examination of the leaking tube and a number of adjacent tubes, visually inspecting the leaking tube from both the inside as well as the area surrounding the failure mechanism. In addition ten other tubes that either exhibited eddy current indications or would represent a baseline condition were removed from heat exchanger 4A for metallurgical examination. Additional analysis and review of heat exchanger leakage history was performed to determine if there are any patterns which can be used for predictive purposes. Compensatory actions have been taken to improve the sensitivity and response time to any future events of this type. The results of these actions are summarized herein

  7. Heat exchanger restart evaluation

    International Nuclear Information System (INIS)

    Morrison, J.M.; Hirst, C.W.; Lentz, T.F.

    1992-01-01

    On December 24, 1991, the K-Reactor was in the shutdown mode with full AC process water flow and full cooling water flow. Safety rod testing was being performed as part of the power ascension testing program. The results of cooling water samples indicated tritium concentrations higher than allowable. Further sampling and testing confirmed a Process Water System to Cooling Water System leak in heat exchanger 4A (HX 4A). The heat exchanger was isolated and the plant shutdown. Heat exchanger 4A was removed from the plant and moved to C-Area prior to performing examinations and diagnostic testing. This included locating and identifying the leaking tube or tubes, eddy current examination of the leaking tube and a number of adjacent tubes, visually inspecting the leaking tube from both the inside as well as the area surrounding the identified tube. The leaking tube was removed and examined metallurgically to determine the failure mechanism. In addition ten other tubes that either exhibited eddy current indications or would represent a baseline condition were removed from heat exchanger 4A for metallurgical examination. Additional analysis and review of heat exchanger leakage history was performed to determine if there are any patterns which can be used for predictive purposes. Compensatory actions have been taken to improve the sensitivity and response time to any future events of this type. The results of these actions are summarized

  8. Purinergic Signalling: Therapeutic Developments

    Directory of Open Access Journals (Sweden)

    Geoffrey Burnstock

    2017-09-01

    Full Text Available Purinergic signalling, i.e., the role of nucleotides as extracellular signalling molecules, was proposed in 1972. However, this concept was not well accepted until the early 1990’s when receptor subtypes for purines and pyrimidines were cloned and characterised, which includes four subtypes of the P1 (adenosine receptor, seven subtypes of P2X ion channel receptors and 8 subtypes of the P2Y G protein-coupled receptor. Early studies were largely concerned with the physiology, pharmacology and biochemistry of purinergic signalling. More recently, the focus has been on the pathophysiology and therapeutic potential. There was early recognition of the use of P1 receptor agonists for the treatment of supraventricular tachycardia and A2A receptor antagonists are promising for the treatment of Parkinson’s disease. Clopidogrel, a P2Y12 antagonist, is widely used for the treatment of thrombosis and stroke, blocking P2Y12 receptor-mediated platelet aggregation. Diquafosol, a long acting P2Y2 receptor agonist, is being used for the treatment of dry eye. P2X3 receptor antagonists have been developed that are orally bioavailable and stable in vivo and are currently in clinical trials for the treatment of chronic cough, bladder incontinence, visceral pain and hypertension. Antagonists to P2X7 receptors are being investigated for the treatment of inflammatory disorders, including neurodegenerative diseases. Other investigations are in progress for the use of purinergic agents for the treatment of osteoporosis, myocardial infarction, irritable bowel syndrome, epilepsy, atherosclerosis, depression, autism, diabetes, and cancer.

  9. Dental therapeutic systems.

    Science.gov (United States)

    Iqbal, Zeenat; Jain, Nilu; Jain, Gaurav K; Talegaonkar, Sushama; Ahuja, Alka; Khar, Roop K; Ahmad, Farhan J

    2008-01-01

    The recognition of periodontal diseases as amenable to local antibiotherapy has resulted in a paradigmatic shift in treatment modalities of dental afflictions. Moreover the presence of antimicrobial resistance, surfacing of untoward reactions owing to systemic consumption of antibiotics has further advocated the use of local delivery of physiologically active substances into the periodontal pocket. While antimicrobials polymerized into acrylic strips, incorporated into biodegradable collagen and hollow permeable cellulose acetate fibers, multiparticulate systems, bio-absorbable dental materials, biodegradable gels/ointments, injectables, mucoadhesive microcapsules and nanospheres will be more amenable for direct placement into the periodontal pockets the lozenges, buccoadhesive tablets, discs or gels could be effectively used to mitigate the overall gingival inflammation. Whilst effecting controlled local delivery of a few milligram of an antibacterial agent within the gingival crevicular fluid for a longer period of time, maintaining therapeutic concentrations such delivery devices will circumvent all adverse effects to non- oral sites. Since the pioneering efforts of Goodson and Lindhe in 1989, delivery at gingival and subgingival sites has witnessed a considerable progress. The interest in locally active systems is evident from the patents being filed and granted. The present article shall dwell in reviewing the recent approaches being proffered in the field. Patents as by Shefer, et al. US patent, 6589562 dealing with multicomponent biodegradable bioadhesive controlled release system for oral care products, Lee, et al. 2001, US patent 6193994, encompassing a locally administrable, biodegradable and sustained-release pharmaceutical composition for periodontitis and process for preparation thereof and method of treating periodontal disease as suggested by Basara in 2004via US patent 6830757, shall be the types of intellectual property reviewed and presented in

  10. Therapeutical aspect of trichomoniasis

    Directory of Open Access Journals (Sweden)

    Vukićević Jelica

    2003-01-01

    Full Text Available Trichomoniasis is frequent, parasitic and sexually transmitted infection of genitourinary tract. It is treated by metronidazole (5-nitroimidazole according to protocol recommended by Center for Disease Control (CDC formerly called: Communicable Disease Center [19]. The resistance of Trichomonas vaginalis (TV strains to metronidazole (MND was described in USA in 1960, and later on in many European countries [8, 9, 10, 11, 12, 13]. In these cases, due to persistent trichomonas infection, it is necessary to repeat MND treatment with moderate modification of dose and/or length of its application. Nevertheless, oncogenic and toxic effects of MND have to be taken into consideration. OBJECT The aim of this study was to investigate and analyze the incidence of TV in STD and lower susceptibility of certain TV strains to MND were analyzed. MATERIAL AND METHODS In three-year period (1999-2001 612 patients (244 females and 368 males suspected of STD were examined clinically and microbiologically at the Institute of Dermatovenereology in Belgrade. The patients detected for TV were treated according to CDC protocol. The affected were considered cured if there was no manifest clinical infection, and no TV verified by microbiological test. Results TV was isolated in 216 patients (35.29 % of all subjects. Trichomonas infection was found in 90 (36.88 % out of 244 tested females and in 126 (32.34 % of 368 males. Clinically manifested infection, with extensive urethral and vaginal secretion, was recorded in 161 patients, while the asymptomatic form was found in 55 subjects. This result indicates the predominance of manifested trichomonas infections (75.54 % of cases. The difference of distribution of clinical forms of trichomoniasis, in relation to sex, was not statistically significant (c2=0.854; p>0.05. The patients with verified trichomonas infection were treated by metronidazole according to CDC protocol. The recommended therapeutical scheme consisted of three

  11. Update heat exchanger designing principles

    International Nuclear Information System (INIS)

    Lipets, A.U.; Yampol'skij, A.E.

    1985-01-01

    Update heat exchanger design principles are analysed. Different coolant pattern in a heat exchanger are considered. It is suggested to rationally organize flow rates irregularity in it. Applying on heat exchanger designing measures on using really existing temperature and flow rate irregularities will permit to improve heat exchanger efficiency. It is expedient in some cases to artificially produce irregularities. In this connection some heat exchanger design principles must be reviewed now

  12. Social dilemmas as exchange dilemmas

    OpenAIRE

    Dijkstra, J.; van Assen, M.A.L.M.

    2016-01-01

    We develop a new paradigm to study social dilemmas, called exchange dilemmas. Exchange dilemmas arise from externalities of exchanges with third parties, and many real-life social dilemmas are more accurately modeled as exchange dilemmas rather than prisoner's dilemmas. Bulding on focusing and framing research we predict that defection is omnipresent in exchange dilemmas, which is corroborated in to very different experiments. Our results suggest that the fundamental problem of cooperation in...

  13. Ion exchange phenomena

    Energy Technology Data Exchange (ETDEWEB)

    Bourg, I.C.; Sposito, G.

    2011-05-01

    Ion exchange phenomena involve the population of readily exchangeable ions, the subset of adsorbed solutes that balance the intrinsic surface charge and can be readily replaced by major background electrolyte ions (Sposito, 2008). These phenomena have occupied a central place in soil chemistry research since Way (1850) first showed that potassium uptake by soils resulted in the release of an equal quantity of moles of charge of calcium and magnesium. Ion exchange phenomena are now routinely modeled in studies of soil formation (White et al., 2005), soil reclamation (Kopittke et al., 2006), soil fertilitization (Agbenin and Yakubu, 2006), colloidal dispersion/flocculation (Charlet and Tournassat, 2005), the mechanics of argillaceous media (Gajo and Loret, 2007), aquitard pore water chemistry (Tournassat et al., 2008), and groundwater (Timms and Hendry, 2007; McNab et al., 2009) and contaminant hydrology (Chatterjee et al., 2008; van Oploo et al., 2008; Serrano et al., 2009).

  14. Sorption by cation exchange

    International Nuclear Information System (INIS)

    Bradbury, M.H.; Baeyens, B.

    1994-04-01

    A procedure for introducing exchange into geochemical/surface complexation codes is described. Beginning with selectivity coefficients, K c , defined in terms of equivalent fractional ion occupancies, a general expression for the molar based exchange code input parameters, K ex , is derived. In natural systems the uptake of nuclides onto complex sorbents often occurs by more than one mechanism. The incorporation of cation exchange and surface complexation into a geochemical code therefore enables sorption by both mechanisms to be calculated simultaneously. The code and model concepts are tested against sets of experimental data from widely different sorption studies. A proposal is made to set up a data base of selectivity coefficients. Such a data base would form part of a more general one consisting of sorption mechanism specific parameters to be used in conjunction with geochemical/sorption codes to model and predict sorption. (author) 6 figs., 6 tabs., 26 refs

  15. Tubular heat exchanger

    International Nuclear Information System (INIS)

    Hayden, Owen; Willby, C.R.

    1976-01-01

    The invention concerns a heat exchanger of which the tubes, placed in a long casing, cross the casing cover in a sealed manner. These tubes are fixed to the tube plate forming this cover or to the branch tubes it comprises by means of compression joints. These joints make it possible to do away with welds that are sources of defects and to improve the operational safety of the apparatus. An advantageous form of the heat exchanger under the invention includes a manifold for each thermal exchange fluid, and one end of each tube is connected to this manifold by a pipe that is itself connected to the tube by a threaded connection. The latter provides for easy disconnection of the pipe in order to introduce a probe for inspecting the state of the tubes [fr

  16. Optical diagnostics of atmospheric pressure air plasmas

    International Nuclear Information System (INIS)

    Laux, C O; Spence, T G; Kruger, C H; Zare, R N

    2003-01-01

    Atmospheric pressure air plasmas are often thought to be in local thermodynamic equilibrium owing to fast interspecies collisional exchange at high pressure. This assumption cannot be relied upon, particularly with respect to optical diagnostics. Velocity gradients in flowing plasmas and/or elevated electron temperatures created by electrical discharges can result in large departures from chemical and thermal equilibrium. This paper reviews diagnostic techniques based on optical emission spectroscopy and cavity ring-down spectroscopy that we have found useful for making temperature and concentration measurements in atmospheric pressure plasmas under conditions ranging from thermal and chemical equilibrium to thermochemical nonequilibrium

  17. Classification of exchange currents

    International Nuclear Information System (INIS)

    Friar, J.L.

    1983-01-01

    After expansion of the vector and axial vector currents in powers of (v/c), a heretofore unremarked regularity results. Meson exchange currents can be classified into types I and II, according to the way they satisfy the constraints of special relativity. The archetypes of these two categories are the impulse approximation to the vector and axial vector currents. After a brief discussion of these constraints, the (rhoπγ) and (ωsigmaγ) exchange currents are constructed and classified, and used to illustrate a number of important points which are often overlooked

  18. Alert Exchange Process Protocol

    Science.gov (United States)

    Groen, Frank

    2015-01-01

    The National Aeronautics and Space Administration of the United States of America (NASA), and the European Space Agency (ESA), and the Japanese Aerospace Exploration Agency (JAXA), acknowledging that NASA, ESA and JAXA have a mutual interest in exchanging Alerts and Alert Status Lists to enhance the information base for each system participant while fortifying the general level of cooperation between the policy agreement subscribers, and each Party will exchange Alert listings on regular basis and detailed Alert information on a need to know basis to the extent permitted by law.

  19. Lipid exchange by ultracentrifugation

    DEFF Research Database (Denmark)

    Drachmann, Nikolaj Düring; Olesen, Claus

    2014-01-01

    , and the complex interplay between the lipids and the P-type ATPases are still not well understood. We here describe a robust method to exchange the majority of the lipids surrounding the ATPase after solubilisation and/or purification with a target lipid of interest. The method is based on an ultracentrifugation...... step, where the protein sample is spun through a dense buffer containing large excess of the target lipid, which results in an approximately 80-85 % lipid exchange. The method is a very gently technique that maintains protein folding during the process, hence allowing further characterization...

  20. Microscale Regenerative Heat Exchanger

    Science.gov (United States)

    Moran, Matthew E.; Stelter, Stephan; Stelter, Manfred

    2006-01-01

    The device described herein is designed primarily for use as a regenerative heat exchanger in a miniature Stirling engine or Stirling-cycle heat pump. A regenerative heat exchanger (sometimes called, simply, a "regenerator" in the Stirling-engine art) is basically a thermal capacitor: Its role in the Stirling cycle is to alternately accept heat from, then deliver heat to, an oscillating flow of a working fluid between compression and expansion volumes, without introducing an excessive pressure drop. These volumes are at different temperatures, and conduction of heat between these volumes is undesirable because it reduces the energy-conversion efficiency of the Stirling cycle.

  1. Small Column Ion Exchange

    International Nuclear Information System (INIS)

    Huff, Thomas

    2010-01-01

    Small Column Ion Exchange (SCIX) leverages a suite of technologies developed by DOE across the complex to achieve lifecycle savings. Technologies are applicable to multiple sites. Early testing supported multiple sites. Balance of SRS SCIX testing supports SRS deployment. A forma Systems Engineering Evaluation (SEE) was performed and selected Small Column Ion Exchange columns containing Crystalline Silicotitanate (CST) in a 2-column lead/lag configuration. SEE considered use of Spherical Resorcinol-Formaldehyde (sRF). Advantages of approach at SRS include: (1) no new buildings, (2) low volume of Cs waste in solid form compared to aqueous strip effluent; and availability of downstream processing facilities for immediate processing of spent resin.

  2. Therapeutic Inertia and Treatment Intensification.

    Science.gov (United States)

    Josiah Willock, Robina; Miller, Joseph B; Mohyi, Michelle; Abuzaanona, Ahmed; Muminovic, Meri; Levy, Phillip D

    2018-01-29

    This review aims to emphasize how therapeutic inertia, the failure of clinicians to intensify treatment when blood pressure rises or remains above therapeutic goals, contributes to suboptimal blood pressure control in hypertensive populations. Studies reveal that the therapeutic inertia is quite common and contributes to suboptimal blood pressure control. Quality improvement programs and standardized approaches to support antihypertensive treatment intensification are ways to combat therapeutic inertia. Furthermore, programs that utilize non-physician medical professionals such as pharmacists and nurses demonstrate promise in mitigating the effects of this important problem. Therapeutic inertia impedes antihypertensive management and requires a broad effort to reduce its effects. There is an ongoing need for renewed focus and research in this area to improve hypertension control.

  3. Exubera. Inhale therapeutic systems.

    Science.gov (United States)

    Bindra, Sanjit; Cefalu, William T

    2002-05-01

    Inhale, in colaboration with Pfizer and Aventis Pharma (formerly Hoechst Marion Roussel; HMR), is developing an insulin formulation utilizing its pulmonary delivery technology for macromolecules for the potential treatment of type I and II diabetes. By July 2001, the phase III program had been completed and the companies had begun to assemble data for MAA and NDA filings; however, it was already clear at this time that additional data might be required for filing. By December 2001, it had been decided that the NDA should include an increased level of controlled, long-term pulmonary safety data in diabetic patients and a major study was planned to be completed in 2002, with the NDA filed thereafter (during 2002). US-05997848 was issued to Inhale Therapeutic Systems in December 1999, and corresponds to WO-09524183, filed in February 1995. Equivalent applications have appeared to date in Australia, Brazil, Canada, China, Czech Republic, Europe, Finland, Hungary, Japan, Norway, New Zealand, Poland and South Africa. This family of applications is specific to pulmonary delivery of insulin. In February 1999, Lehman Brothers gave this inhaled insulin a 60% probability of reaching market, with a possible launch date of 2001. The analysts estimated peak sales at $3 billion in 2011. In May 2000, Aventis predicted that estimated peak sales would be in excess of $1 billion. In February 2000, Merrill Lynch expected product launch in 2002 and predicted that it would be a multibillion-dollar product. Analysts Merril Lynch predicted, in September and November 2000, that the product would be launched by 2002, with sales in that year of e75 million, rising to euro 500 million in 2004. In April 2001, Merrill Lynch predicted that filing for this drug would occur in 2001. Following the report of the potential delay in regulatory filing, issued in July 2001, Deutsche Banc Alex Brown predicted a filing would take place in the fourth quarter of 2002 and launch would take place in the first

  4. Cold plasmas

    International Nuclear Information System (INIS)

    Franz, G.

    1990-01-01

    This textbook discusses the following topics: Phenomenological description of a direct current glow discharge; the plasma (temperature distribution and measurement, potential variation, electron energy distribution function, charge neutralization, wall potentials, plasma oscillations); Production of charge carriers (ions, electrons, ionization in the cathode zone, negative glowing zone, Faraday dark space, positive column, anode zone, hollow cathode discharges); RF-discharges (charge carrier production, RF-Shields, scattering mechanisms); Sputtering (ion-surface interaction, kinetics, sputtering yield and energy distribution, systems and conditions, film formation and stresses, contamination, bias techniques, multicomponent film deposition, cohesion, magnetrons, triode systems, plasma enhanced chemical vapor deposition); Dry etching (sputter etching, reactive etching, topography, process control, quantitative investigations); Etching mechanisms (etching of Si and SiO 2 with CF 4 , of III/V-compound-semiconductors, combination of isotrope and anisotrope etching methods, surface cleaning); ion beam systems (applications, etching); Dyclotron-resonance-systems (electron cyclotron resonance systems, whistler-sources and 'resonant inductive plasma etching'); Appendix (electron energy distribution functions, Bohm's transition zone, plasma oscillations, scattering cross sections and mean free path, metastable states, Child-Langmuir-Schottky equation, loss mechanisms, charge carrier distribution in the positive column, breakdown at high frequencies, motion in a magnetic field, skin depth of an electric field for a HF-discharge, whistler waves, dispersion relations for plane wave propagation). (orig.) With 138 figs

  5. Plasma heating

    International Nuclear Information System (INIS)

    Wilhelm, R.

    1989-01-01

    Successful plasma heating is essential in present fusion experiments, for the demonstration of DpT burn in future devices and finally for the fusion reactor itself. This paper discusses the common heating systems with respect to their present performance and their applicability to future fusion devices. The comparative discussion is oriented to the various function of heating, which are: - plasma heating to fusion-relevant parameters and to ignition in future machines, -non-inductive, steady-pstate current drive, - plasma profile control, -neutral gas breakdown and plasma build-up. In view of these different functions, the potential of neutral beam injection (NBI) and the various schemes of wave heating (ECRH, LH, ICRH and Alven wave heating) is analyzed in more detail. The analysis includes assessments of the present physical and technical state of these heating methods, and makes suggestions for future developments and about outstanding problems. Specific attention is given to the still critical problem of efficient current drive, especially with respect to further extrapolation towards an economically operating tokamak reactor. Remarks on issues such as reliability, maintenance and economy conclude this comparative overview on plasma heating systems. (author). 43 refs.; 13 figs.; 3 tabs

  6. PLASMA DEVICE

    Science.gov (United States)

    Gow, J.D.; Wilcox, J.M.

    1961-12-26

    A device is designed for producing and confining highenergy plasma from which neutrons are generated in copious quantities. A rotating sheath of electrons is established in a radial electric field and axial magnetic field produced within the device. The electron sheath serves as a strong ionizing medium to gas introdueed thereto and also functions as an extremely effective heating mechanism to the resulting plasma. In addition, improved confinement of the plasma is obtained by ring magnetic mirror fields produced at the ends of the device. Such ring mirror fields are defined by the magnetic field lines at the ends of the device diverging radially outward from the axis of the device and thereafter converging at spatial annular surfaces disposed concentrically thereabout. (AFC)

  7. Plasma properties

    International Nuclear Information System (INIS)

    Weitzner, H.

    1989-08-01

    A cursory examination of the research activities of the Magneto-Fluid Dynamics Division for the calendar year 1988 shows the effects of the gradual transformation of the group. Although our principal activity, fusion plasma physics research, is unchanged, the work shows closer ties to problems relevant to present experiments than previously. Most notable is the concentrated effort on tokamak equilibrium and transport. We are exploring the implication of turbulence induced transport, resistive MHD effects, neoclassical transport, and possible interpretations of transport based on classical phenomena. In addition, one of our members has chosen to focus on problems of enhanced statistical methods for interpretation of experiments. All of this activity preceded the Tokamak Transport Initiative and reflects our active involvement and concern with the world-wide tokamak program. Since equilibrium and transport are by no means the only theoretical plasma physics problems affecting fusion devices we continue substantial efforts in wave propagation and heating, particle simulation of plasmas, stability theory, enhancement of numerical algorithms, and general plasma physics. We are attempting to develop effective numerical schemes for the Boltzmann equation, adaptive grid methods for MHD, and particle simulation of boundary and antenna effects. Many of these topics reflect our continuing concern to maintain a modest effort in the development of theoretical models and tools for problems of real significance to fusion, but not necessarily of immediate highest priority. We select problems which we expect to become extremely important in the future. Our space plasma physics activities, funded by agencies other than DOE, transfers knowledge learned in fusion plasma physics to another area and conversely stimulates work also relevant to fusion problems

  8. Innovative heat exchangers

    CERN Document Server

    Scholl, Stephan

    2018-01-01

    This accessible book presents unconventional technologies in heat exchanger design that have the capacity to provide solutions to major concerns within the process and power-generating industries. Demonstrating the advantages and limits of these innovative heat exchangers, it also discusses micro- and nanostructure surfaces and micro-scale equipment, and introduces pillow-plate, helical and expanded metal baffle concepts. It offers step-by-step worked examples, which provide instructions for developing an initial configuration and are supported by clear, detailed drawings and pictures. Various types of heat exchangers are available, and they are widely used in all fields of industry for cooling or heating purposes, including in combustion engines. The market in 2012 was estimated to be U$ 42.7 billion and the global demand for heat exchangers is experiencing an annual growth of about 7.8 %. The market value is expected to reach U$ 57.9 billion in 2016, and approach U$ 78.16 billion in 2020. Providing a valua...

  9. Organizing Equity Exchanges

    Science.gov (United States)

    Schaper, Torsten

    In the last years equity exchanges have diversified their operations into business areas such as derivatives trading, post-trading services, and software sales. Securities trading and post-trading are subject to economies of scale and scope. The integration of these functions into one institution ensures efficiency by economizing on transactions costs.

  10. Resonance charge exchange processes

    International Nuclear Information System (INIS)

    Duman, E.L.; Evseev, A.V.; Eletskij, A.V.; Radtsig, A.A.; Smirnov, B.M.

    1979-01-01

    The calculation results for the resonance charge exchange cross sections for positive and negative atomic and molecular ions are given. The calculations are performed on the basis of the asymptotic theory. The factors affecting the calculation accuracy are analysed. The calculation data for 28 systems are compared with the experiment

  11. Chapter 11. Heat Exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Rafferty, Kevin D.; Culver, Gene

    1998-01-01

    Most geothermal fluids, because of their elevated temperature, contain a variety of dissolved chemicals. These chemicals are frequently corrosive toward standard materials of construction. As a result, it is advisable in most cases to isolate the geothermal fluid from the process to which heat is being transferred. The task of heat transfer from the geothermal fluid to a closed process loop is most often handled by a plate heat exchanger. The two most common types used in geothermal applications are: bolted and brazed. For smaller systems, in geothermal resource areas of a specific character, downhole heat exchangers (DHEs) provide a unique means of heat extraction. These devices eliminate the requirement for physical removal of fluid from the well. For this reason, DHE-based systems avoid entirely the environmental and practical problems associated with fluid disposal. Shell and tube heat exchangers play only a minor role in low-temperature, direct-use systems. These units have been in common use in industrial applications for many years and, as a result, are well understood. For these reasons, shell and tube heat exchangers will not be covered in this chapter.

  12. Basic Exchange Rate Theories

    NARCIS (Netherlands)

    J.G.M. van Marrewijk (Charles)

    2005-01-01

    textabstractThis four-chapter overview of basic exchange rate theories discusses (i) the elasticity and absorption approach, (ii) the (long-run) implications of the monetary approach, (iii) the short-run effects of monetary and fiscal policy under various economic conditions, and (iv) the transition

  13. Method for exchanging data

    NARCIS (Netherlands)

    2014-01-01

    The present invention relates to a method for exchanging data between at least two servers with use of a gateway. Preferably the method is applied to healthcare systems. Each server holds a unique federated identifier, which identifier identifies a single patient (P). Thus, it is possible for the

  14. Baltic Exchange toodi Tallinna

    Index Scriptorium Estoniae

    2007-01-01

    Viimane osa merekonteineritesse kokkupakitud Londoni laevandus- ja merebörsi Baltic Exchange'i endise peakorteri detailidest jõudis 2007. a. juunis Tallinna. Hoone detailid ostnud ärimehed Heiti Hääl ja Eerik-Niiles Kross plaanivad leida hoonele koha Tallinna kesklinnas. E.-N. Krossi kommentaar

  15. Telephone Exchange Maintenance

    CERN Multimedia

    2005-01-01

    Urgent maintenance work on CERN telephone exchanges will be performed on 24 March from 6 a.m. to 8 a.m. Telephone services may be disrupted or even interrupted during this time. For more details, please contact us by email at Standard.Telephone@cern.ch.

  16. Heat exchanger vibration

    International Nuclear Information System (INIS)

    Richards, D.J.W.

    1977-01-01

    The heat exchangers of various types are common items of plant in the generation and transmission of electricity. The amount of attention given to the flow-induced vibrations of heat exchangers by designers is usually related to the operational history of similar items of plant. Consequently, if a particular design procedure yields items of plant which behave in a satisfactory manner during their operational life, there is little incentive to improve or refine the design procedure. On the other hand, failures of heat exchangers clearly indicate deficiencies in the design procedures or in the data available to the designer. When such failures are attributable to flow-induced vibrations, the identification of the mechanisms involved is a prime importance. Ideally, basic research work provides the background understanding and the techniques necessary to be able to identify the important mechanisms. In practice, the investigation of a flow-induced vibration problem may identify the presence of mechanisms but may not be able to quantify their effects adequately. In these circumstances the need for additional work is established and the objectives of the research programme emerge. The purpose of this paper is to outline the background to the current research programme at C.E.R.L. on heat exchanger vibration

  17. Application of ion exchangers

    International Nuclear Information System (INIS)

    Markhol, M.

    1985-01-01

    Existing methods of multi-element separation for radiochemical analysis are considered. The majority of existing methods is noted to be based on application of organic and inorganic ion exchangers. Distillation, coprecipitation, extraction as well as combination of the above methods are also used. Concrete flowsheets of multi-element separation are presented

  18. Fuel exchanger control device

    International Nuclear Information System (INIS)

    Kurabayashi, Masaharu.

    1985-01-01

    Purpose: To improve the stability and the operationability of the fuel exchanging work by checking the validity of the data before the initiation of the work. Constitution: A floppy disc stores the initial charging state data showing the arrangement of fuel assemblies in the reactor core pool, data showing the working procedures for the fuel exchange and a final charged state data upon completion of the work. The initial data and the procedure data are read from the disk and stored once into a memory. Then, the initial data are sequentially performed on the memory in accordance with the procedure data and, thereafter, they were compared with the final data read from the disk. After confirming that there are no errors in the working data, the procedure data are orderly instructed to the fuel exchanger for performing fuel replacement. Accordingly, since the data are checked before the initiation of the work, the fuel exchange can be performed automatically thereby improving the operationability thereof. (Yoshino, Y.)

  19. Upright heat exchanger

    International Nuclear Information System (INIS)

    Martoch, J.; Kugler, V.; Krizek, V.; Strmiska, F.

    1988-01-01

    The claimed heat exchanger is characteristic by the condensate level being maintained directly in the exchanger while preserving the so-called ''dry'' tube plate. This makes it unnecessary to build another pressure vessel into the circuit. The design of the heat exchanger allows access to both tube plates, which facilitates any repair. Another advantage is the possibility of accelerating the indication of leakage from the space of the second operating medium which is given by opening the drainage pipes of the lower bundle into the collar space and from there through to the indication pipe. The exchanger is especially suitable for deployment in the circuits of nuclear power plants where the second operating medium will be hot water of considerably lower purity than is that of the condensate. A rapid display of leakage can prevent any long-term penetration of this water into the condensate, which would result in worsening water quality in the entire secondary circuit of the nuclear power plant. (J.B.). 1 fig

  20. Heat exchanger vibration

    Energy Technology Data Exchange (ETDEWEB)

    Richards, D J.W. [CERL, CEGB, Leatherhead, Surrey (United Kingdom)

    1977-12-01

    The heat exchangers of various types are common items of plant in the generation and transmission of electricity. The amount of attention given to the flow-induced vibrations of heat exchangers by designers is usually related to the operational history of similar items of plant. Consequently, if a particular design procedure yields items of plant which behave in a satisfactory manner during their operational life, there is little incentive to improve or refine the design procedure. On the other hand, failures of heat exchangers clearly indicate deficiencies in the design procedures or in the data available to the designer. When such failures are attributable to flow-induced vibrations, the identification of the mechanisms involved is a prime importance. Ideally, basic research work provides the background understanding and the techniques necessary to be able to identify the important mechanisms. In practice, the investigation of a flow-induced vibration problem may identify the presence of mechanisms but may not be able to quantify their effects adequately. In these circumstances the need for additional work is established and the objectives of the research programme emerge. The purpose of this paper is to outline the background to the current research programme at C.E.R.L. on heat exchanger vibration.

  1. Electron plasma waves and plasma resonances

    International Nuclear Information System (INIS)

    Franklin, R N; Braithwaite, N St J

    2009-01-01

    In 1929 Tonks and Langmuir predicted of the existence of electron plasma waves in an infinite, uniform plasma. The more realistic laboratory environment of non-uniform and bounded plasmas frustrated early experiments. Meanwhile Landau predicted that electron plasma waves in a uniform collisionless plasma would appear to be damped. Subsequent experimental work verified this and revealed the curious phenomenon of plasma wave echoes. Electron plasma wave theory, extended to finite plasmas, has been confirmed by various experiments. Nonlinear phenomena, such as particle trapping, emerge at large amplitude. The use of electron plasma waves to determine electron density and electron temperature has not proved as convenient as other methods.

  2. Surge of plasma waves in an inhomogeneous plasma

    International Nuclear Information System (INIS)

    Benhassine, Mohammed

    1985-01-01

    The first part of this research thesis addresses the propagation of waves in a plasma. It presents the equation of propagation of an electromagnetic wave in a plasma without magnetic field, and analyses the propagation in an inhomogeneous medium. The second part addresses the wave-particle interaction: interaction between electrons and an electromagnetic wave, between electrons and an electrostatic wave (trapping), and between electrons and a localised electric field. The third chapter presents the analytic theory of oscillations of a cold plasma (macroscopic equations in Lagrangian coordinates, analytic solution before surge). The next chapter discusses physical interpretations before the wave surge, after the wave surge, and about energy exchange (within or outside of resonance). Numerical simulations and their results are then reported and discussed. The sixth chapter addresses the case of an electrostatic wave surge in a hot plasma. It notably addresses the following aspects: equivalence between the description of moments and the Waterbag model, interaction between non linearity and thermal effects, variation of electric field amplitude with temperature. Results of numerical simulations are presented, and the last part addresses experimental predictions for microwaves-plasma interaction and laser-matter interaction [fr

  3. Sensitive radioimmunoassay for plasma arginine vasopressin

    International Nuclear Information System (INIS)

    Thibonnier, M.; Soto, M.E.; Corvol, P.; Milliez, P.; Marchetti, J.; Menard, J.

    1980-01-01

    Using an ion exchange resin, a sensitive radioimmunoassay for plasma arginine vasopressin (AVP) was developed. This assay was characterized by the absence of blank values, an excellent recovery rate, great sensitivity (0.1 pg of AVP was significantly detected) and reproducibility. In 8 normal men, plasma AVP after overnight dehydration was 1.57+-0.17 pg/ml, and dropped to 0.58+-0.11 pg/ml after 20 ml/kg oral water loading. Significant correlations between plasma AVP levels and plasma or urinary osmolality confirm the validity of this assay. In complete pituitary diabetes insipidus (n=4) plasma AVP was undetectable whereas it was frankly increased in Schwartz-Bartter syndrome (3 to 33 pg/ml, n=8) [fr

  4. Fundamental aspects of plasma chemical physics transport

    CERN Document Server

    Capitelli, Mario; Laricchiuta, Annarita

    2013-01-01

    Fundamental Aspects of Plasma Chemical Physics: Tranpsort develops basic and advanced concepts of plasma transport to the modern treatment of the Chapman-Enskog method for the solution of the Boltzmann transport equation. The book invites the reader to consider actual problems of the transport of thermal plasmas with particular attention to the derivation of diffusion- and viscosity-type transport cross sections, stressing the role of resonant charge-exchange processes in affecting the diffusion-type collision calculation of viscosity-type collision integrals. A wide range of topics is then discussed including (1) the effect of non-equilibrium vibrational distributions on the transport of vibrational energy, (2) the role of electronically excited states in the transport properties of thermal plasmas, (3) the dependence of transport properties on the multitude of Saha equations for multi-temperature plasmas, and (4) the effect of the magnetic field on transport properties. Throughout the book, worked examples ...

  5. ''Dusty plasmas''

    International Nuclear Information System (INIS)

    Tsytovich, V.N.; Bingham, R.; Angelis, U. de

    1989-09-01

    The field of ''dusty plasmas'' promises to be a very rewarding topic of research for the next decade or so, not only from the academic point of view where the emphasis is on developing the theory of the often complex collective and non-linear processes, but also from the point of view of applications in astrophysics, space physics, environmental and energy research. In this ''comment'' we should like to sketch the current development of this fast growing and potentially very important research area. We will discuss the new features of ''dusty'' plasmas in the most general terms and then briefly mention some successful applications and effects which have already been examined. (author)

  6. Effect of processing on functional properties of animal blood plasma.

    Science.gov (United States)

    Del Hoyo, P; Rendueles, M; Díaz, M

    2008-04-01

    A number of functional and physical properties such as solubility, foam capacity, emulsifying stability and interfacial tension were compared for standard plasma, plasma decationed by ion exchange and plasma deionized by ultrafiltration (UF). The changes in functional properties can determine the use of a protein as an additive to a food product or invalidate its use. All samples had good functional properties and hence could be used in the formulation of food products. Results showed that ion exchange and UF improved emulsifying capacity while having little effect on the other functional properties.

  7. Human Factor in Therapeutic Relationship

    Directory of Open Access Journals (Sweden)

    Ramazan Akdogan

    2011-03-01

    Full Text Available herapeutic relationship is a professional relationship that has been structured based on theoretical props. This relationship is a complicated, wide and unique relationship which develops between two people, where both sides' personality and attitudes inevitably interfere. Therapist-client relationship experienced through transference and counter transference, especially in psychodynamic approaches, is accepted as the main aspect of therapeutic process. However, the approaches without dynamic/deterministic tendency also take therapist-client relationship into account seriously and stress uniqueness of interaction between two people. Being a person and a human naturally sometimes may negatively influence the relationship between the therapist and client and result in a relationship going out of the theoretical frame at times. As effective components of a therapeutic process, the factors that stem from being human include the unique personalities of the therapist and the client, their values and their attitude either made consciously or subconsciously. Literature has shown that the human-related factors are too effective to be denied in therapeutic relationship process. Ethical and theoretical knowledge can be inefficient to prevent the negative effects of these factors in therapeutic process at which point a deep insight and supervision would have a critical role in continuing an acceptable therapeutic relationship. This review is focused on the reflection of some therapeutic factors resulting from being human and development of counter transference onto the therapeutic process.

  8. Population pharmacokinetics of phenobarbital in infants with neonatal encephalopathy treated with therapeutic hypothermia.

    Science.gov (United States)

    Shellhaas, Renée A; Ng, Chee M; Dillon, Christina H; Barks, John D E; Bhatt-Mehta, Varsha

    2013-02-01

    Phenobarbital is the first-line treatment for neonatal seizures. Many neonates with hypoxic ischemic encephalopathy are treated with therapeutic hypothermia, and about 40% have clinical seizures. Little is known about the pharmacokinetics of phenobarbital in infants with hypoxic ischemic encephalopathy who undergo therapeutic hypothermia. The objective of this study was to determine the effect of therapeutic hypothermia on phenobarbital pharmacokinetics, taking into account maturational changes. Level 3 neonatal ICU. Infants with hypoxic ischemic encephalopathy and suspected seizures, all treated with phenobarbital. Some of these infants also received treatment with therapeutic hypothermia. None. A retrospective cohort study of 39 infants with hypoxic ischemic encephalopathy treated with phenobarbital (20 were treated with therapeutic hypothermia and 19 were not). Data on phenobarbital plasma concentrations were collected in 39 subjects with hypoxic ischemic encephalopathy with or without therapeutic hypothermia. Using nonlinear mixed-effects modeling, population pharmacokinetics of phenobarbital were developed with a total of 164 plasma concentrations. A one-compartment model best described the pharmacokinetics. The clearance of phenobarbital was linearly related to body weight and matured with increasing age with a maturation half-life of 22.1 days. Therapeutic hypothermia did not influence the pharmacokinetic parameters of phenobarbital. Therapeutic hypothermia does not influence the clearance of phenobarbital after accounting for weight and age. Standard phenobarbital dosing is appropriate for the initial treatment of seizures in neonates with hypoxic ischemic encephalopathy treated with therapeutic hypothermia.

  9. Plasma physics and engineering

    CERN Document Server

    Fridman, Alexander

    2011-01-01

    Part I: Fundamentals of Plasma Physics and Plasma ChemistryPlasma in Nature, in the Laboratory, and in IndustryOccurrence of Plasma: Natural and Man MadeGas DischargesPlasma Applications, Plasmas in IndustryPlasma Applications for Environmental ControlPlasma Applications in Energy ConversionPlasma Application for Material ProcessingBreakthrough Plasma Applications in Modern TechnologyElementary Processes of Charged Species in PlasmaElementary Charged Particles in Plasma and Their Elastic and Inelastic CollisionsIonization ProcessesMechanisms of Electron Losses: The Electron-Ion RecombinationEl

  10. Analytical applications of ion exchangers

    CERN Document Server

    Inczédy, J

    1966-01-01

    Analytical Applications of Ion Exchangers presents the laboratory use of ion-exchange resins. This book discusses the development in the analytical application of ion exchangers. Organized into 10 chapters, this book begins with an overview of the history and significance of ion exchangers for technical purposes. This text then describes the properties of ion exchangers, which are large molecular water-insoluble polyelectrolytes having a cross-linked structure that contains ionic groups. Other chapters consider the theories concerning the operation of ion-exchange resins and investigate th

  11. [End therapeutic nihilism towards COPD].

    Science.gov (United States)

    Juergens, Uwe R

    2007-03-15

    Prevention of COPD requires appropriate patient education, especially of adolescents, as well as the establishment of an effective national health policy. The new GOLD guidelines represent the current standard of knowledge on the management of chronic, progressive, obstructive pulmonary diseases. It points out that COPD is avoidable and treatable,and hence, there is no reason for therapeutic nihilism. Chronic bronchitis preceding a progressive respiratory obstruction cannot be improved with the presently available respiratory therapeutics. For this reason, therapeutic measures concentrate on the avoidance of exacerbations, which are primarily responsible for the severity of the course of COPD.

  12. Frontiers in nano-therapeutics

    CERN Document Server

    Tasnim, Nishat; Sai Krishna, Katla; Kalagara, Sudhakar; Narayan, Mahesh; Noveron, Juan C; Joddar, Binata

    2017-01-01

    This brief highlights recent research advances in the area of nano-therapeutics. Nanotechnology holds immense potential for application in a wide range of biological and engineering applications such as molecular sensors for disease diagnosis, therapeutic agents for the treatment of diseases, a vehicle for delivering therapeutics and imaging agents for theranostic applications, both in-vitro and in-vivo. The brief is grouped into the following sections namely, A) Discrete Nanosystems ; B) Anisotropic Nanoparticles; C) Nano-films/coated/layered and D) Nano-composites.

  13. Therapeutic hypothermia for acute stroke

    DEFF Research Database (Denmark)

    Olsen, Tom Skyhøj; Weber, Uno Jakob; Kammersgaard, Lars Peter

    2003-01-01

    Experimental evidence and clinical experience show that hypothermia protects the brain from damage during ischaemia. There is a growing hope that the prevention of fever in stroke will improve outcome and that hypothermia may be a therapeutic option for the treatment of stroke. Body temperature...... obvious therapeutic potential, hypothermia as a form of neuroprotection for stroke has been investigated in only a few very small studies. Therapeutic hypothermia is feasible in acute stroke but owing to serious side-effects--such as hypotension, cardiac arrhythmia, and pneumonia--it is still thought...

  14. Horizontal Curve Virtual Peer Exchange : an RSPCB Peer Exchange

    Science.gov (United States)

    2014-06-01

    This report summarizes the Horizontal Curve Virtual Peer Exchange sponsored by the Federal Highway Administration (FHWA) Office of Safetys Roadway Safety Professional Capacity Building Program on June 17, 2014. This virtual peer exchange was the f...

  15. Plasma-parameter measurements using neutral-particle-beam attenuation

    International Nuclear Information System (INIS)

    Foote, J.H.; Molvik, A.W.; Turner, W.C.

    1982-01-01

    Intense and energetic neutral-particle-beam injection used for fueling or heating magnetically confined, controlled-fusion experimental plasmas can also provide diagnostic measurements of the plasmas. The attenuation of an atomic beam (mainly from charge-exchange and ionization interactions) when passing through a plasma gives the plasma line density. Orthogonal arrays of highly collimated detectors of the secondary-electron-emission type have been used in magnetic-mirror experiments to measure neutral-beam attenuation along chords through the plasma volume at different radial and axial positions. The radial array is used to infer the radial plasma-density profile; the axial array, to infer the axial plasma-density profile and the ion angular distribution at the plasma midplane

  16. Complex (dusty) plasmas: Current status, open issues, perspectives

    International Nuclear Information System (INIS)

    Fortov, V.E.; Ivlev, A.V.; Khrapak, S.A.; Khrapak, A.G.; Morfill, G.E.

    2005-01-01

    The field of complex (dusty) plasmas-low-temperature plasmas containing charged microparticles-is reviewed: The major types of experimental complex plasmas are briefly discussed. Various elementary processes, including grain charging in different regimes, interaction between charged particles, and momentum exchange between different species are investigated. The major forces on microparticles and features of the particle dynamics in complex plasmas are highlighted. An overview of the wave properties in different phase states, as well as recent results on the phase transitions between different crystalline and liquid states are presented. Fluid behaviour of complex plasmas and the onset of cooperative phenomena are discussed. Properties of the magnetized complex plasmas and plasmas with nonspherical particles are briefly mentioned. In conclusion, possible applications of complex plasmas, interdisciplinary aspects, and perspectives are discussed

  17. Plasma fluctuation measurements in tokamaks using beam-plasma interactions

    International Nuclear Information System (INIS)

    Fonck, R.J.; Duperrex, P.A.; Paul, S.F.

    1990-01-01

    High-frequency observations of light emitted from the interactions between plasma ions and injected neutral beam atoms allow the measurement of moderate-wavelength fluctuations in plasma and impurity ion densities. To detect turbulence in the local plasma ion density, the collisionally excited fluorescence from a neutral beam is measured either separately at several spatial points or with a multichannel imaging detector. Similarly, the role of impurity ion density fluctuations is measured using charge exchange recombination excited transitions emitted by the ion species of interest. This technique can access the relatively unexplored region of long-wavelength plasma turbulence with k perpendicular ρ i much-lt 1, and hence complements measurements from scattering experiments. Optimization of neutral beam geometry and optical sightlines can result in very good localization and resolution (Δx≤1 cm) in the hot plasma core region. The detectable fluctuation level is determined by photon statistics, atomic excitation processes, and beam stability, but can be as low as 0.2% in a 100 kHz bandwidth over the 0--1 MHz frequency range. The choices of beam species (e.g., H 0 , He 0 , etc.), observed transition (e.g., H α , L α , He I singlet or triplet transitions, C VI Δn=1, etc.) are dictated by experiment-specific factors such as optical access, flexibility of beam operation, plasma conditions, and detailed experimental goals. Initial tests on the PBX-M tokamak using the H α emissions from a heating neutral beam show low-frequency turbulence in the edge plasma region

  18. On plasma ion beam formation in the Advanced Plasma Source

    International Nuclear Information System (INIS)

    Harhausen, J; Foest, R; Hannemann, M; Ohl, A; Brinkmann, R P; Schröder, B

    2012-01-01

    The Advanced Plasma Source (APS) is employed for plasma ion-assisted deposition (PIAD) of optical coatings. The APS is a hot cathode dc glow discharge which emits a plasma ion beam to the deposition chamber at high vacuum (p ≲ 2 × 10 −4 mbar). It is established as an industrial tool but to date no detailed information is available on plasma parameters in the process chamber. As a consequence, the details of the generation of the plasma ion beam and the reasons for variations of the properties of the deposited films are barely understood. In this paper the results obtained from Langmuir probe and retarding field energy analyzer diagnostics operated in the plasma plume of the APS are presented, where the source was operated with argon. With increasing distance to the source exit the electron density (n e ) is found to drop by two orders of magnitude and the effective electron temperature (T e,eff ) drops by a factor of five. The parameters close to the source region read n e ≳ 10 11 cm −3 and T e,eff ≳ 10 eV. The electron distribution function exhibits a concave shape and can be described in the framework of the non-local approximation. It is revealed that an energetic ion population leaves the source region and a cold ion population in the plume is build up by charge exchange collisions with the background neutral gas. Based on the experimental data a scaling law for ion beam power is deduced, which links the control parameters of the source to the plasma parameters in the process chamber. (paper)

  19. Plasma chromograninx

    DEFF Research Database (Denmark)

    Goetze, Jens P; Hilsted, Linda M; Rehfeld, Jens F

    2014-01-01

    Cardiovascular risk assessment remains difficult in elderly patients. We examined whether chromogranin A (CgA) measurement in plasma may be valuable in assessing risk of death in elderly patients with symptoms of heart failure in a primary care setting. A total of 470 patients (mean age 73 years...

  20. Burning plasmas

    International Nuclear Information System (INIS)

    Furth, H.P.; Goldston, R.J.; Zweben, S.J.

    1990-10-01

    The fraction of fusion-reaction energy that is released in energetic charged ions, such as the alpha particles of the D-T reaction, can be thermalized within the reacting plasma and used to maintain its temperature. This mechanism facilitates the achievement of very high energy-multiplication factors Q, but also raises a number of new issues of confinement physics. To ensure satisfactory reaction operation, three areas of energetic-ion interaction need to be addressed: single-ion transport in imperfectly symmetric magnetic fields or turbulent background plasmas; energetic-ion-driven (or stabilized) collective phenomena; and fusion-heat-driven collective phenomena. The first of these topics is already being explored in a number of tokamak experiments, and the second will begin to be addressed in the D-T-burning phase of TFTR and JET. Exploration of the third topic calls for high-Q operation, which is a goal of proposed next-generation plasma-burning projects. Planning for future experiments must take into consideration the full range of plasma-physics and engineering R ampersand D areas that need to be addressed on the way to a fusion power demonstration

  1. The Metaphysics of Economic Exchanges

    Directory of Open Access Journals (Sweden)

    Massin Olivier

    2017-05-01

    Full Text Available What are economic exchanges? The received view has it that exchanges are mutual transfers of goods motivated by inverse valuations thereof. As a corollary, the standard approach treats exchanges of services as a subspecies of exchanges of goods. We raise two objections against this standard approach. First, it is incomplete, as it fails to take into account, among other things, the offers and acceptances that lie at the core of even the simplest cases of exchanges. Second, it ultimately fails to generalize to exchanges of services, in which neither inverse preferences nor mutual transfers hold true. We propose an alternative definition of exchanges, which treats exchanges of goods as a special case of exchanges of services and which builds in offers and acceptances. According to this theory: (i The valuations motivating exchanges are propositional and convergent rather than objectual and inverse; (ii All exchanges of goods involve exchanges of services/actions, but not the reverse; (iii Offers and acceptances, together with the contractual obligations and claims they bring about, lie at the heart of all cases of exchange.

  2. Investigation of metal ions in fusion plasmas using emission spectroscopy

    International Nuclear Information System (INIS)

    Tale, I.

    2005-01-01

    Full text: The Latvian and Portugal Associations are performing development of advanced plasma - facing system using the liquid metal limiter. The objectives of this project require study of the influence of the liquid metal limiter on the main plasma parameters, including concentration of evaporated metal atoms in plasma. The fusion plasmas are related to the dense hot plasmas. The required average ion temperature according to the ITER project (International Thermonuclear Experimental Reactor) is 8,0 keV (9,3 x 10 7 0 K), the average electron temperature - 8,9 keV (1,04 x 10 8 0 K). Plasma temperature operated in the research tokamak ISSTOK, involved in testing of liquid metal limiter concept is considerably less, being of order of 10 50 K. The ionization degree of metal atoms considerably depends on the plasma ion temperature. Density of metal vapours in plasma can be estimated using the following two spectroscopic methods: The fluorescence of the multiple ionised metal ions in steady state concentration; The charge exchange emission during ionisation of evaporated metal ions. In the first step of development of testing system of metal vapours the equipment and instrumentation for charge exchange spectroscopy of Ga and In has been elaborated taking into account the following features of plasma emission. The Ga emission lines occur on the background high temperature plasma black body emission and stray light. Radial distribution of Ga in plasma in the facing plane of Ga flux is desirable

  3. The use of cold plasma generators in medicine

    Directory of Open Access Journals (Sweden)

    Kolomiiets R.O.

    2017-04-01

    Full Text Available Cold plasma treatment of wounds is a modern area of therapeutic medicine. We describe the physical mechanisms of cold plasma, the principles of therapeutic effects and design of two common types of cold plasma generators for medical use. This work aims at disclosing the basic principles of construction of cold atmospheric plasma generators in medicine and prospects for their further improvement. The purpose of this work is to improve the existing cold atmospheric plasma generators for use in medical applications. Novelty of this work consists in the application of new principles of construction of cold atmospheric plasmas medical apparatus, namely the combination of the gas discharge chamber, electrodes complex shape forming device and plasma flow in a single package. This helps to achieve a significant reduction in the size of the device, and a discharge chamber design change increases the therapeutic effect. The design of cold atmospheric plasma generator type «pin-to-hole», which is able to control parameters using the plasma current (modulation fluctuations in the primary winding and mechanically (using optional rotary electrode. It is also possible to combine some similar generators in the set, which will increase the surface area of the plasma treatment. We consider the basic principles of generating low atmospheric plasma flow, especially the formation of the plasma jet, changing its shape and modulation stream. The features of cold plasma generator design and information about prospects for further application, and opportunities for further improvement are revealed. The recommendations for further use of cold atmospheric plasma generators in medicine are formulated.

  4. Design Considerations in Therapeutic Exergaming

    OpenAIRE

    Doyle, Julie; Kelly, Daniel; Caulfield, B.

    2011-01-01

    In this paper we discuss the importance of feedback in therapeutic exergaming. It is widely believed that exergaming benefits the patient in terms of encouraging adherence and boosting the patient’s confidence of correct execution and feedback is essential in achieving these. However, feedback and in particular visual feedback, may also have potential negative effects on the quality of the exercise. We describe in this paper a prototype single-sensor therapeutic exergame that we have develope...

  5. Evaluation of therapeutic patient education

    OpenAIRE

    D'Ivernois , Jean-François; Gagnayre , Rémi; Assal , Jean-Philippe; Golay , Alain; Libion , France; Deccache , Alain

    2006-01-01

    9 pages; These guidelines mainly focus on the principles of evaluating Therapeutic Patient Education; Over the past thirty years, therapeutic patient education (TPE) has become an essential part of the treatment of long-term diseases. Evaluations of this new practice are expected, and are sometimes imposed according to protocols and criteria that do not always reflect the complexity of changes taking place within patients and healthcare providers. Sometimes, expected results are not achieved ...

  6. Profiling Prostate Cancer Therapeutic Resistance

    OpenAIRE

    Cameron A. Wade; Natasha Kyprianou

    2018-01-01

    The major challenge in the treatment of patients with advanced lethal prostate cancer is therapeutic resistance to androgen-deprivation therapy (ADT) and chemotherapy. Overriding this resistance requires understanding of the driving mechanisms of the tumor microenvironment, not just the androgen receptor (AR)-signaling cascade, that facilitate therapeutic resistance in order to identify new drug targets. The tumor microenvironment enables key signaling pathways promoting cancer cell survival ...

  7. Data Exchange Inventory (DEXI) System

    Data.gov (United States)

    Social Security Administration — DEXI is an intranet application used by SSA users to track all incoming and outgoing data exchanges between SSA and our data exchange partners. Information such as...

  8. l~hrombotic thrombocytic purpura plasma infusion or exchange?

    African Journals Online (AJOL)

    1991-02-02

    Feb 2, 1991 ... prednisone, employed for its anti-inflammatory effect on the vascular endothelium .... tained-release morphine formulations (such as MST), has im- ... ntlSis has been made, that there are no psychological contrain- di{.:ations ...

  9. Automatic fuel exchanging device

    International Nuclear Information System (INIS)

    Takahashi, Fuminobu.

    1984-01-01

    Purpose: To enable to designate the identification number of a fuel assembly in a nuclear reactor pressure vessel thereby surely exchanging the designated assembly within a short time. Constitution: Identification number (or letter) pressed on a grip of a fuel assembly is to be detected by a two-dimensional ultrasonic probe of a pull-up mechanism. When the detected number corresponds with the designated number, a control signal is outputted, whereby the pull-up drive control mechanism or pull-up mechanism responds to pull-up and exchange the fuel assembly of the identified number. With such a constitution, the fuel assembly can rapidly and surely be recognized even if pressed letters deviate to the left or right of the probe, and further, the hinge portion and the signal processing portion can be simplified. (Horiuchi, T.)

  10. Manufacture of heat exchangers

    International Nuclear Information System (INIS)

    Burton, J.E.; Tombs, R.W.T.

    1980-01-01

    A tube bundle for use in a heat exchanger has a series of spaced parallel tubes supported by tube plates and is manufactured by depositing welding material around the end of each tube, machining the deposited material to form an annular flange around the end of the tube and welding the flange into apertures in the tube plate. Preferably the tubes have a length which is slightly less than the distance between the outer surfaces of the tube plates and the deposited material is deposited so that it overlaps and protects the end surfaces of the tubes. A plug may be inserted in the bore of the tubes during the welding material deposition which, as described, is effected by manual metal arc welding. One use of heat exchangers incorporating a tube bundle manufactured as above is in apparatus for reducing the volume of, and recovering nitric acid from, radioactive effluents from a nuclear reprocessing plant. (author)

  11. Compact cryocooler heat exchangers

    International Nuclear Information System (INIS)

    Luna, J.; Frederking, T.H.K.

    1991-01-01

    Compact heat exchangers are subject to different constraints as a room temperature gas is cooled down by a cold stream returning from a JT valve (or a similar cryoprocess component). In particular, the optimization of exchangers for liquid helium systems has to cover a wide range in temperature and density of the fluid. In the present work we address the following thermodynamic questions: 1. The optimization of intermediate temperatures which optimize stage operation (a stage is assumed to have a constant cross section); 2. The optimum temperature difference available for best overall economic performance values. The results are viewed in the context of porous media concepts applied to rather low speeds of fluid flow in narrow passages. In this paper examples of fluid/solid constraints imposed in this non-classical low temperature area are presented

  12. Magnetoresistive waves in plasmas

    International Nuclear Information System (INIS)

    Felber, F.S.; Hunter, R.O. Jr.; Pereira, N.R.; Tajima, T.

    1982-01-01

    The self-generated magnetic field of a current diffusing into a plasma between conductors can magnetically insulate the plasma. Propagation of magnetoresistive waves in plasmas is analyzed. Applications to plasma opening switches are discussed

  13. Exchange currents in nuclear physics

    International Nuclear Information System (INIS)

    Truglik, Eh.

    1980-01-01

    Starting from Adler's low-energy theorem for the soft pion production amplitudes the predictions of the meson exchange currents theory for the nuclear physics are discussed. The results are reformulated in terms of phenomenological lagrangians. This method allows one to pass naturally to the more realistic case of hard mesons. The predictions are critically compared with the existing experimental data. The main processes in which vector isovector exchange currents, vector isoscalar exchange currents and axial exchange currents take place are pointed out

  14. Hydrogen Exchange Mass Spectrometry

    Science.gov (United States)

    Mayne, Leland

    2018-01-01

    Hydrogen exchange (HX) methods can reveal much about the structure, energetics, and dynamics of proteins. The addition of mass spectrometry (MS) to an earlier fragmentation-separation HX analysis now extends HX studies to larger proteins at high structural resolution and can provide information not available before. This chapter discusses experimental aspects of HX labeling, especially with respect to the use of MS and the analysis of MS data. PMID:26791986

  15. Exchange rate rebounds after foreign exchange market interventions

    Science.gov (United States)

    Hoshikawa, Takeshi

    2017-03-01

    This study examined the rebounds in the exchange rate after foreign exchange intervention. When intervention is strongly effective, the exchange rate rebounds at next day. The effect of intervention is reduced slightly by the rebound after the intervention. The exchange rate might have been 67.12-77.47 yen to a US dollar without yen-selling/dollar-purchasing intervention of 74,691,100 million yen implemented by the Japanese government since 1991, in comparison to the actual exchange rate was 103.19 yen to the US dollar at the end of March 2014.

  16. Heat exchanger tube tool

    International Nuclear Information System (INIS)

    Gugel, G.

    1976-01-01

    Certain types of heat-exchangers have tubes opening through a tube sheet to a manifold having an access opening offset from alignment with the tube ends. A tool for inserting a device, such as for inspection or repair, is provided for use in such instances. The tool is formed by a flexible guide tube insertable through the access opening and having an inner end provided with a connector for connection with the opening of the tube in which the device is to be inserted, and an outer end which remains outside of the chamber, the guide tube having adequate length for this arrangement. A flexible transport hose for internally transporting the device slides inside of the guide tube. This hose is long enough to slide through the guide tube, into the heat-exchanger tube, and through the latter to the extent required for the use of the device. The guide tube must be bent to reach the end of the heat-exchanger tube and the latter may be constructed with a bend, the hose carrying anit-friction elements at interspaced locations along its length to make it possible for the hose to negotiate such bends while sliding to the location where the use of the device is required

  17. Timing Foreign Exchange Markets

    Directory of Open Access Journals (Sweden)

    Samuel W. Malone

    2016-03-01

    Full Text Available To improve short-horizon exchange rate forecasts, we employ foreign exchange market risk factors as fundamentals, and Bayesian treed Gaussian process (BTGP models to handle non-linear, time-varying relationships between these fundamentals and exchange rates. Forecasts from the BTGP model conditional on the carry and dollar factors dominate random walk forecasts on accuracy and economic criteria in the Meese-Rogoff setting. Superior market timing ability for large moves, more than directional accuracy, drives the BTGP’s success. We explain how, through a model averaging Monte Carlo scheme, the BTGP is able to simultaneously exploit smoothness and rough breaks in between-variable dynamics. Either feature in isolation is unable to consistently outperform benchmarks throughout the full span of time in our forecasting exercises. Trading strategies based on ex ante BTGP forecasts deliver the highest out-of-sample risk-adjusted returns for the median currency, as well as for both predictable, traded risk factors.

  18. The exchangeability of shape

    Directory of Open Access Journals (Sweden)

    Kaba Dramane

    2010-10-01

    Full Text Available Abstract Background Landmark based geometric morphometrics (GM allows the quantitative comparison of organismal shapes. When applied to systematics, it is able to score shape changes which often are undetectable by traditional morphological studies and even by classical morphometric approaches. It has thus become a fast and low cost candidate to identify cryptic species. Due to inherent mathematical properties, shape variables derived from one set of coordinates cannot be compared with shape variables derived from another set. Raw coordinates which produce these shape variables could be used for data exchange, however they contain measurement error. The latter may represent a significant obstacle when the objective is to distinguish very similar species. Results We show here that a single user derived dataset produces much less classification error than a multiple one. The question then becomes how to circumvent the lack of exchangeability of shape variables while preserving a single user dataset. A solution to this question could lead to the creation of a relatively fast and inexpensive systematic tool adapted for the recognition of cryptic species. Conclusions To preserve both exchangeability of shape and a single user derived dataset, our suggestion is to create a free access bank of reference images from which one can produce raw coordinates and use them for comparison with external specimens. Thus, we propose an alternative geometric descriptive system that separates 2-D data gathering and analyzes.

  19. Social exchange: Relations and networks

    OpenAIRE

    Dijkstra, Jacob

    2015-01-01

    In this short paper, I review the literature on social exchange networks, with specific attention to theoretical and experimental research. I indicate how social exchange theory is rooted in general social theory and mention a few of its main links to social network analysis and empirical network research. The paper provides an accessible entry into the literature on social exchange.

  20. O3 and NOx Exchange

    NARCIS (Netherlands)

    Loubet, B.; Castell, J.F.; Laville, P.; Personne, E.; Tuzet, A.; Ammann, C.; Emberson, L.; Ganzeveld, L.; Kowalski, A.S.; Merbold, L.; Stella, P.; Tuovinen, J.P.

    2015-01-01

    This discussion was based on the background document “Review on modelling atmosphere-biosphere exchange of Ozone and Nitrogen oxides”, which reviews the processes contributing to biosphere-atmosphere exchange of O3 and NOx, including stomatal and non-stomatal exchange of O3 and NO, NO2.

  1. Integrated Foreign Exchange Risk Management

    DEFF Research Database (Denmark)

    Aabo, Tom; Høg, Esben; Kuhn, Jochen

    Empirical research has focused on export as a proxy for the exchange rate exposure and the use of foreign exchange derivatives as the instrument to deal with this exposure. This empirical study applies an integrated foreign exchange risk management approach with a particular focus on the role...

  2. Exchangers man the pumps: Functional interplay between proton pumps and proton-coupled Ca exchangers.

    Science.gov (United States)

    Barkla, Bronwyn J; Hirschi, Kendal D; Pittman, Jon K

    2008-05-01

    Tonoplast-localised proton-coupled Ca(2+) transporters encoded by cation/H(+)exchanger (CAX) genes play a critical role in sequestering Ca(2+) into the vacuole. These transporters may function in coordination with Ca(2+) release channels, to shape stimulus-induced cytosolic Ca(2+) elevations. Recent analysis of Arabidopsis CAX knockout mutants, particularly cax1 and cax3, identified a variety of phenotypes including sensitivity to abiotic stresses, which indicated that these transporters might play a role in mediating the plant's stress response. A common feature of these mutants was the perturbation of H(+)-ATPase activity at both the tonoplast and the plasma membrane, suggesting a tight interplay between the Ca(2+)/H(+) exchangers and H(+) pumps. We speculate that indirect regulation of proton flux by the exchangers may be as important as the direct regulation of Ca(2+) flux. These results suggest cautious interpretation of mutant Ca(2+)/H(+) exchanger phenotypes that may be due to either perturbed Ca(2+) or H(+) transport.

  3. Analysis of defect tubes of fast reactor heat exchanger

    International Nuclear Information System (INIS)

    Rukhlyada, N.Ya.

    2014-01-01

    The experimental Auger electron spectroscopy and X-ray diffraction microanalysis data of laboratory investigations of defect tubes of heat exchanger with sodium coolant are presented. Element distribution through depth of corrosion layers form on the side of coolant (sodium) and on the surface contacting with steam in heat exchanger tube is studied. Sodium presence through all thickness of the tube is determined. It is shown that treatment of 12Cr18N9 steel surface by plasma pulses decreases intergranular corrosion susceptibility. It is related with structural changes of surface layer (∼ 20 μm), its enrichment by chromium and formation of chromium oxide protective film [ru

  4. 16. Hot dense plasma atomic processes

    International Nuclear Information System (INIS)

    Werner, Dappen; Totsuji, H.; Nishii, Y.

    2002-01-01

    This document gathers 13 articles whose common feature is to deal with atomic processes in hot plasmas. Density functional molecular dynamics method is applied to the hydrogen plasma in the domain of liquid metallic hydrogen. The effects of the density gradient are taken into account in both the electronic kinetic energy and the exchange energy and it is shown that they almost cancel with each other, extending the applicability of the Thomas-Fermi-Dirac approximation to the cases where the density gradient is not negligible. Another article reports about space and time resolved M-shell X-ray measurements of a laser-produced gas jet xenon plasma. Plasma parameters have been measured by ion acoustic and electron plasma waves Thomson scattering. Photo-ionization becomes a dominant atomic process when the density and the temperature of plasmas are relatively low and when the plasma is submitted to intense external radiation. It is shown that 2 plasmas which have a very different density but have the same ionization parameters, are found in a similar ionization state. Most radiation hydrodynamics codes use radiative opacity data from available libraries of atomic data. Several articles are focused on the determination of one group Rosseland and Planck mean analytical formulas for several single elements used in inertial fusion targets. In another paper the plasma density effect on population densities, effective ionization, recombination rate coefficients and on emission lines from carbon and Al ions in hot dense plasma, is studied. The last article is devoted to a new atomic model in plasmas that considers the occupation probability of the bound state and free state density in the presence of the plasma micro-field. (A.C.)

  5. Plasma physics

    CERN Document Server

    Cairns, R A

    1985-01-01

    This book is intended as an introduction to plasma physics at a level suitable for advanced undergraduates or beginning postgraduate students in physics, applied mathematics or astrophysics. The main prerequisite is a knowledge of electromagnetism and of the associated mathematics of vector calculus. SI units are used throughout. There is still a tendency amongst some plasma physics researchers to· cling to C.g.S. units, but it is the author's view that universal adoption of SI units, which have been the internationally agreed standard since 1960, is to be encouraged. After a short introductory chapter, the basic properties of a plasma con­ cerning particle orbits, fluid theory, Coulomb collisions and waves are set out in Chapters 2-5, with illustrations drawn from problems in nuclear fusion research and space physics. The emphasis is on the essential physics involved and (he theoretical and mathematical approach has been kept as simple and intuitive as possible. An attempt has been made to draw attention t...

  6. Plasma shutdown device

    International Nuclear Information System (INIS)

    Hosogane, Nobuyuki; Nakayama, Takahide.

    1985-01-01

    Purpose: To prevent concentration of plasma currents to the plasma center upon plasma shutdown in a torus type thermonuclear device by the injection of fuels to the plasma center thereby prevent plasma disruption at the plasma center. Constitution: The plasma shutdown device comprises a plasma current measuring device that measures the current distribution of plasmas confined within a vacuum vessel and outputs a control signal for cooling the plasma center when the plasma currents concentrate to the plasma center and a fuel supply device that supplies fuels to the plasma center for cooling the center. The fuels are injected in the form of pellets into the plasmas. The direction and the velocity of the injection are set such that the pellets are ionized at the center of the plasmas. (Horiuchi, T.)

  7. Mastering Microsoft Exchange Server 2010

    CERN Document Server

    McBee, Jim

    2010-01-01

    A top-selling guide to Exchange Server-now fully updated for Exchange Server 2010. Keep your Microsoft messaging system up to date and protected with the very newest version, Exchange Server 2010, and this comprehensive guide. Whether you're upgrading from Exchange Server 2007 SP1 or earlier, installing for the first time, or migrating from another system, this step-by-step guide provides the hands-on instruction, practical application, and real-world advice you need.: Explains Microsoft Exchange Server 2010, the latest release of Microsoft's messaging system that protects against spam and vir

  8. Progress in liquid ion exchangers

    International Nuclear Information System (INIS)

    Nakagawa, Genkichi

    1974-01-01

    Review is made on the extraction with anion exchangers and the extraction with liquid cation exchangers. On the former, explanation is made on the extraction of acids, the relation between anion exchange and the extraction of metals, the composition of the metallic complexes that are extracted, and the application of the extraction with anion exchangers to analytical chemistry. On the latter, explanation is made on the extraction of metals and its application to analytical chemistry. The extraction with liquid ion exchangers is suitable for the operation in chromatography, because the distribution of extracting agents into aqueous phase is small, and extraction equilibrium is quickly reached, usually within 1 to several minutes. The separation by means of anion exchangers is usually made from hydrochloric acid solution. For example, Brinkman et al. determined Rf values for more than 50 elements by thin layer chromatography. Tables are given for showing the structure of the liquid ion exchangers and the polymerized state of various amines. (Mori, K.)

  9. The therapeutic role in later life: husbands, wives and couples.

    Science.gov (United States)

    Anderson, T B; Earle, J R; Longino, C F

    1997-01-01

    The present study investigates the extent to which marital partners are different or similar in their ways of enacting the therapeutic, or supportive, role. Specifically, the article compares husbands and wives categorically as in non-dyadic studies and then as marital partners as in dyadic studies. In addition, this study, by using data from the Aging Couples Study, included only dual-earner couples so as to control for the effects of work life on marital relations. Results showed that studies of individual married men and women understate the differences between marital partners in that some wives "overbenefit" in the exchange of conjugal supports. However, husbands more often "overbenefit." Findings also indicated that the norm of reciprocity does not prevail regarding the extent of support, although it does for the types of support exchanged.

  10. Plasma Medicine: Current Achievements and Future Prospects

    Science.gov (United States)

    Laroussi, Mounir

    2012-10-01

    Research on the biomedical applications of low temperature plasmas started with small scale experiments that were simply aimed at discovering what happens to biological cells when exposed to the chemically rich environment of plasma. These early experiments took place in the mid to late 1990s. As interest in this multidisciplinary field dramatically rose, various engineering and physics groups collaborated with biologists and medical experts to investigate the use of plasma technology as a basis for innovative medical approaches to cure various diseases. However, many questions concerning the fundamental mechanisms involved in cell-plasma interaction remained unanswered. As a result various workshops were organized to gather the diverse research community in the field of plasma medicine in order to have a fruitful exchange of ideas regarding the scientific challenges that needed to be surmounted to advance and expand the field's knowledge base. The present GEC workshop continues this important tradition of scientific cooperation since there is still a significant lack of understanding of many of the biochemical and molecular pathways that come into play when biological cells are exposed to plasmas. In this talk, first background information on the various plasma devices developed in our institute will be presented. This will be followed by a summary of our work on the effects of plasmas on prokaryotic and eukaryotic cells. The talk will be concluded by presenting our vision of the future of the field and an outline of the main challenges that need to be overcome if practical medical applications are to be achieved.

  11. Potential therapeutic applications of biosurfactants.

    Science.gov (United States)

    Gudiña, Eduardo J; Rangarajan, Vivek; Sen, Ramkrishna; Rodrigues, Lígia R

    2013-12-01

    Biosurfactants have recently emerged as promising molecules for their structural novelty, versatility, and diverse properties that are potentially useful for many therapeutic applications. Mainly due to their surface activity, these molecules interact with cell membranes of several organisms and/or with the surrounding environments, and thus can be viewed as potential cancer therapeutics or as constituents of drug delivery systems. Some types of microbial surfactants, such as lipopeptides and glycolipids, have been shown to selectively inhibit the proliferation of cancer cells and to disrupt cell membranes causing their lysis through apoptosis pathways. Moreover, biosurfactants as drug delivery vehicles offer commercially attractive and scientifically novel applications. This review covers the current state-of-the-art in biosurfactant research for therapeutic purposes, providing new directions towards the discovery and development of molecules with novel structures and diverse functions for advanced applications. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. RNAi Therapeutics in Autoimmune Disease

    Directory of Open Access Journals (Sweden)

    Seunghee Cha

    2013-03-01

    Full Text Available Since the discovery of RNA interference (RNAi, excitement has grown over its potential therapeutic uses. Targeting RNAi pathways provides a powerful tool to change biological processes post-transcriptionally in various health conditions such as cancer or autoimmune diseases. Optimum design of shRNA, siRNA, and miRNA enhances stability and specificity of RNAi-based approaches whereas it has to reduce or prevent undesirable immune responses or off-target effects. Recent advances in understanding pathogenesis of autoimmune diseases have allowed application of these tools in vitro as well as in vivo with some degree of success. Further research on the design and delivery of effectors of RNAi pathway and underlying molecular basis of RNAi would warrant practical use of RNAi-based therapeutics in human applications. This review will focus on the approaches used for current therapeutics and their applications in autoimmune diseases, including rheumatoid arthritis and Sjögren’s syndrome.

  13. Conflicts in the therapeutic field

    Directory of Open Access Journals (Sweden)

    Antonino Aprea

    2012-06-01

    Full Text Available How the analytical knowledge that compare human consciousness with that, even more disturbing, moving behind his fifth can be said to be “for peace”? It can be - and this will be the contribution of the proposal - the same tortuous and enigmatic of therapeutic practice, with its hesitations and his impulses, to outline a path crossing and overcoming the conflict? May, finally, peace, in the sense of feasibility of intra-and interpersonal dialectic instead of tearing and hostileconfrontation with oneself and with the other, to be a reference in some crucial pivot of ethical therapeutic work? To these questions the intervention seeks to answer retracing some of the highlights of almost three years of therapeutic work with a young woman and her family.

  14. Study of 25 cases of exchange transfusion by reconstituted blood in hemolytic disease of newborn

    Science.gov (United States)

    Sharma, D. C.; Rai, Sunita; Mehra, Aakash; Kaur, M. M.; Sao, Satya; Gaur, Ajay; Sapra, Rahul

    2007-01-01

    This study was aimed to review and establish the practice of exchange transfusion (ET) with reconstituted blood in neonates and to observe fall of bilirubin and its comparison with related studies. Twenty-five neonates diagnosed as hemolytic disease of newborn (HDN) were selected for this study, in which exchange transfusion was carried out as one of the treatments for hyperbilirubinemia. Out of the 25 cases, 15 were of Rhesus (Rh) HDN, while ABO and other blood groups constituted 6 and 4 HDN cases respectively. First, the neonates's and mother's blood samples were subjected to relevant investigations. After that, for neonates having Rh HDN, O Rh negative cells suspended in AB plasma were given, O Rh positive cells suspended in AB plasma were given to ABO HDN; and O positive cells, which were indirect Coomb's cross-matched compatible with neonates’ and mother's serum / plasma, suspended in AB plasma were given to the neonates having HDN because of other blood group antibodies. The exchange transfusion (ET) was carried out taking all aseptic precautions by Push-Pull technique with double-volume exchange transfusion method. The average post-exchange fall in serum indirect bilirubin was (52.01%) in all 25 cases, which was found to be more significant than the previous studies. Looking into the superiority of the exchange transfusion in HDN by reconstituted blood, the reconstituted blood can be modified and supplied as per the requirement and conditions. PMID:21938234

  15. Study of 25 cases of exchange transfusion by reconstituted blood in hemolytic disease of newborn

    Directory of Open Access Journals (Sweden)

    Sharma D

    2007-01-01

    Full Text Available This study was aimed to review and establish the practice of exchange transfusion (ET with reconstituted blood in neonates and to observe fall of bilirubin and its comparison with related studies. Twenty-five neonates diagnosed as hemolytic disease of newborn (HDN were selected for this study, in which exchange transfusion was carried out as one of the treatments for hyperbilirubinemia. Out of the 25 cases, 15 were of Rhesus (Rh HDN, while ABO and other blood groups constituted 6 and 4 HDN cases respectively. First, the neonates′ and mother′s blood samples were subjected to relevant investigations. After that, for neonates having Rh HDN, O Rh negative cells suspended in AB plasma were given, O Rh positive cells suspended in AB plasma were given to ABO HDN; and O positive cells, which were indirect Coomb′s cross-matched compatible with neonates′ and mother′s serum / plasma, suspended in AB plasma were given to the neonates having HDN because of other blood group antibodies. The exchange transfusion (ET was carried out taking all aseptic precautions by Push-Pull technique with double-volume exchange transfusion method. The average post-exchange fall in serum indirect bilirubin was (52.01% in all 25 cases, which was found to be more significant than the previous studies. Looking into the superiority of the exchange transfusion in HDN by reconstituted blood, the reconstituted blood can be modified and supplied as per the requirement and conditions.

  16. Reactor-produced therapeutic radioisotopes

    International Nuclear Information System (INIS)

    Knapp, F.F. Jr.

    2002-01-01

    The significant worldwide increase in therapeutic radioisotope applications in nuclear medicine, oncology and interventional cardiology requires the dependable production of sufficient levels of radioisotopes for these applications (Reba, 2000; J. Nucl. Med., 1998; Nuclear News, 1999; Adelstein and Manning, 1994). The issues associated with both accelerator- and reactor-production of therapeutic radioisotopes is important. Clinical applications of therapeutic radioisotopes include the use of both sealed sources and unsealed radiopharmaceutical sources. Targeted radiopharmaceutical agents include those for cancer therapy and palliation of bone pain from metastatic disease, ablation of bone marrow prior to stem cell transplantation, treatment modalities for mono and oligo- and polyarthritis, for cancer therapy (including brachytherapy) and for the inhibition of the hyperplastic response following coronary angioplasty and other interventional procedures (For example, see Volkert and Hoffman, 1999). Sealed sources involve the use of radiolabeled devices for cancer therapy (brachytherapy) and also for the inhibition of the hyperplasia which is often encountered after angioplasty, especially with the exponential increase in the use of coronary stents and stents for the peripheral vasculature and other anatomical applications. Since neutron-rich radioisotopes often decay by beta decay or decay to beta-emitting daughter radioisotopes which serve as the basis for radionuclide generator systems, reactors are expected to play an increasingly important role for the production of a large variety of therapeutic radioisotopes required for these and other developing therapeutic applications. Because of the importance of the availability of reactor-produced radioisotopes for these applications, an understanding of the contribution of neutron spectra for radioisotope production and determination of those cross sections which have not yet been established is important. This

  17. Influence by early plasma exchange on biochemical index and prognosis in severe hyperlipidemic ;pancreatitis patients%早期血浆置换对重症高脂血症性胰腺炎患者的生化指标及预后的影响

    Institute of Scientific and Technical Information of China (English)

    殷卫兵; 张西亮

    2016-01-01

    目的:观察早期血浆置换对重症高脂血症性胰腺炎(HLP)的生化指标改变及治疗效果。方法40例重症高脂血症性胰腺炎患者,随机分为对照组23例和治疗组17例。对照组采用内科传统治疗;治疗组在对照组的基础上给予早期单次床旁血浆置换治疗。比较两组血患者常规白细胞(WBC)、血清淀粉酶(AMY)、血糖(GLU)、甘油三酯(TG)指标。结果治疗前,两组患者血常规WBC、AMY、TG、GLU比较,差异无统计学意义(P>0.05)。治疗后第3天,两组患者血常规WBC、AMY、TG、GLU低于治疗前(P0.05). In the 3rd day after treatment, both groups had lower WBC, AMY, TG and GLU than those before treatment (P<0.01). The treatment group had all lower WBC as (7.89±1.53)×109/L, AMY as (201.32±18.20) U/L, GLU as (7.15±0.98) mmol/L and TG as (5.82±3.01) mmol/L than WBC as (9.26±2.06)×109/L, AMY as (252.43±19.08) U/L, GLU as (8.43±1.66) mmol/L and TG as (11.72±3.64) mmol/L in the control group (P<0.05). Conclusion Implement of early plasma exchange can remarkably improve biochemical index in patients with severe hyperlipidemic pancreatitis, reduce inflammatory reactions and prevent disease development.

  18. [Therapeutic touch and anorexia nervosa].

    Science.gov (United States)

    Satori, Nadine

    2016-01-01

    An innovative practice, therapeutic touch has been used for around ten years in the treatment of eating disorders. Delivered by nurse clinicians having received specific training, this approach is based on nursing diagnoses which identify the major symptoms of this pathology. The support is built around the body and its perceptions. Through the helping relationship, it mobilises the patient's resources to favour a relationship of trust, a letting-go, physical, psychological and emotional relaxation, and improves the therapeutic alliance. Copyright © 2016. Published by Elsevier Masson SAS.

  19. Separation of transfer ribonucleic acids on polystyrene anion exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Singhal, R.P.; Griffin, G.D.; Novelli, G.D.

    1976-11-16

    The transfer RNA separation by chromatography on strong-base-polystyrene exchange materials is examined and compared with the widely used reversed-phase chromatography. Results indicate important differences in some transfer RNA (tRNA) elution patterns by the anion-exchange chromatography, as compared with the reversed-phase chromatography. Transfer RNAs containing hydrophobic groups are adsorbed more strongly. The anion exchanger has twice the number of theoretical plates. Single peaks of tRNA/sub 2//sup Glu/ and tRNA/sub 1//sup Phe/ obtained from the reversed-phase column give multiple peaks on polystyrene anion-exchange chromatography. All six leucine tRNAs (Escherichia coli) and differences in tRNA populations synthesized during early and late stages of the dividing lymphocytes from normal human blood can be characterized by the anion-exchange chromatography. Different separation profiles are obtained by two separation systems for tyrosine tRNAs from mouse liver and mouse-plasma-cell tumor. The results indicate that, in contrast to the reversed-phase chromatography, strong-base-polystyrene anion-exchange chromatography is capable of separating tRNAs with minor structural differences.

  20. How is plasma profile determined?

    International Nuclear Information System (INIS)

    Itoh, Kimitaka; Itoh, Sanae

    1991-01-01

    The plasma of toroidal system magnetic field confinement which is represented by tokamak is realized as dissipating structure which is maintained by the supply of energy and particles. Besides the spatial distributions of heat, particles and momentum inside plasma take various forms, there are the transition phenomena among the distributions with different forms, intermittent energy loss, the exchange of spatial positions among ions and so on, accordingly confined plasma is the treasure house of the transport phenomena accompanied by various temporal and spatial scales. Now might be the time that the unknown physics being concealed with veil becomes clear. In this report, by taking tokamaks as the example, concerning the transport phenomena in plasma, the recent development on the physical phenomena and the comparison of the theoretical model with the experiment is explained. The formulation of transport phenomena, the elementary process of transport by flickering, transport matrix, waves in drift frequency band, boundary condition, the comparison of transport in steady state, the research on the time change of distribution, and the correlation of flickering and transport are described. (K.I.)

  1. The plasma automata network (PAN) architecture

    International Nuclear Information System (INIS)

    Cameron-Carey, C.M.

    1991-01-01

    Conventional neural networks consist of processing elements which are interconnected according to a specified topology. Typically, the number of processing elements and the interconnection topology are fixed. A neural network's information processing capability lies mainly in the variability of interconnection strengths, which directly influence activation patterns; these patterns represent entities and their interrelationships. Contrast this architecture, with its fixed topology and variable interconnection strengths, against one having dynamic topology and fixed connection strength. This paper reports on this proposed architecture in which there are no connections between processing elements. Instead, the processing elements form a plasma, exchanging information upon collision. A plasma can be populated with several different types of processing elements, each with their won activation function and self-modification mechanism. The activation patterns that are the plasma;s response to stimulation drive natural selection among processing elements which evolve to optimize performance

  2. Diagnostics of atmospheric pressure air plasmas

    International Nuclear Information System (INIS)

    Laux, C.O.; Kruger, C.H.; Zare, R.N.

    2001-01-01

    Atmospheric pressure air plasmas are often thought to be in Local Thermodynamics Equilibrium (LTE) owing to fast interspecies collisional exchanges at high pressure. As will be seen here, this assumption cannot be relied upon, particularly with respect to optical diagnostics. Large velocity gradients in flowing plasmas and/or elevated electron temperatures created by electrical discharges can result in large departures from chemical and thermal equilibrium. Diagnostic techniques based on optical emission spectroscopy (OES) and Cavity Ring-Down Spectroscopy (CRDS) have been developed and applied at Stanford University to the investigation of atmospheric pressure plasmas under conditions ranging from thermal and chemical equilibrium to thermochemical nonequilibrium. This article presents a review of selected temperature and species concentration measurement techniques useful for the study of air and nitrogen plasmas

  3. Reciprocity in therapeutic relationships: A conceptual review.

    Science.gov (United States)

    Sandhu, Sima; Arcidiacono, Eleonora; Aguglia, Eugenio; Priebe, Stefan

    2015-12-01

    Reciprocity has generally been understood as a process of giving and taking, within an exchange of emotions or services, and has long been recognized as a central part of human life. However, an understanding of reciprocity in professional helping relationships has seldom received attention, despite movements in mental health care towards more collaborative approaches between service users and professionals. In this review, a systematic search of the published papers was conducted in order to explore how reciprocity is conceptualized and understood as part of the dyadic therapeutic relationship between professionals and service users. Eleven papers met our inclusion criteria and a narrative synthesis was used to synthesize the key concepts of reciprocity. The concepts of: 'dynamic equilibrium', 'shared affect', 'asymmetric alliance', and 'recognition as a fellow human being' were recurrent in understandings of reciprocity in professional contexts. These conceptualizations of reciprocity were also linked to specific behavioural and psychological processes. The findings suggest that reciprocity may be conceptualized and incorporated as a component of mental health care, with recurrent and observable processes which may be harnessed to promote positive outcomes for service users. To this end, we make recommendations for further research to progress and develop reciprocal processes in mental health care. © 2015 Australian College of Mental Health Nurses Inc.

  4. Exchange functional by a range-separated exchange hole

    International Nuclear Information System (INIS)

    Toyoda, Masayuki; Ozaki, Taisuke

    2011-01-01

    An approximation to the exchange-hole density is proposed for the evaluation of the exact exchange energy in electronic structure calculations within the density-functional theory and the Kohn-Sham scheme. Based on the localized nature of density matrix, the exchange hole is divided into the short-range (SR) and long-range (LR) parts by using an adequate filter function, where the LR part is deduced by matching of moments with the exactly calculated SR counterpart, ensuring the correct asymptotic -1/r behavior of the exchange potential. With this division, the time-consuming integration is truncated at a certain interaction range, largely reducing the computation cost. The total energies, exchange energies, exchange potentials, and eigenvalues of the highest-occupied orbitals are calculated for the noble-gas atoms. The close agreement of the results with the exact values suggests the validity of the approximation.

  5. Exchange and fellowship programme

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1959-04-15

    By February 1959, the IAEA had received and considered nearly 300 nominations from 31 countries for nuclear science fellowships. More than 200 of the candidates - from 29 countries - had been selected for placement in centres of training in 21 countries. The programme covers three types of training: 1. General techniques training: to develop skills in the use of some fundamental techniques in the field of nuclear energy; 2. Specialist training: to prepare specialists in the theoretical and experimental aspects of the science and technology of nuclear energy; 3. Research training: to provide advanced training, including active participation in research work; this is for persons potentially qualified to develop and carry out research programmes in the basic sciences and engineering. The duration of training varies from some weeks to five or six years. The long-duration training is given at universities or educational establishments of university level, and is of special interest to Member States lacking personnel with the requisite university education. Under its 1959 exchange and fellowship programme, the Agency will be in a position to award over 400 fellowships. Some of these will be paid out of the Agency's operating fund, while 130 fellowships have been offered directly to IAEA by Member States for training at their universities or institutes. There are two new features in the Agency's 1959 programme. One provides for fellowships for scientific research work, the other is the exchange of specialists

  6. Fuel exchanging apparatus

    International Nuclear Information System (INIS)

    Imada, Takahiko; Sato, Hideo.

    1975-01-01

    Object: To provide a centripetal device, which has an initial spring force greater than a frictional force in an oscillating direction of a telescope mast, on a mast fixing device mounted on a body of fuel exchanging apparatus so that the telescope mast may be secured quickly returning to a predetermined initial position. Structure: When the body of fuel exchanging apparatus is stopped at a predetermined position, a tension spring, which has an initial spring force greater than a frictional force in an oscillating direction of the telescope mast, causes a lug to be forced by means of a push rod to position a sliding base plate to its original position. At the same time, a device of similar structure causes an operating arm to be positioned to the original position, and a lock pin urged by a cylinder is inserted into a through hole in the sliding base plate and operating arm so that the telescope mast may be fixed and retained. (Hanada, M.)

  7. Therapy Talk: Analyzing Therapeutic Discourse

    Science.gov (United States)

    Leahy, Margaret M.

    2004-01-01

    Therapeutic discourse is the talk-in-interaction that represents the social practice between clinician and client. This article invites speech-language pathologists to apply their knowledge of language to analyzing therapy talk and to learn how talking practices shape clinical roles and identities. A range of qualitative research approaches,…

  8. Therapeutic approaches to genetic disorders

    African Journals Online (AJOL)

    salah

    Although prevention is the ideal goal for genetic disorders, various types of therapeutic ... The patient being ... pirical or aimed at controlling or mediating signs and symptoms without care. ... plications and gene therapy approaches .... genes family, have opened a wide and .... cancer where nanoparticles are used to.

  9. Medical therapeutic effect of hyperthyroidism

    International Nuclear Information System (INIS)

    Lee, K.B.

    1980-01-01

    In order to compare the therapeutic effect as well as side effects between antithyroid therapy and radioiodine therapy in hyperthyroidism, the author evaluated 111 cases of hyperthyroidism which were composed of 57 patients with antithyroid treatment, 23 patients with combined treatment comprising of antithyroid and radioactive iodine ( 131 I) and 31 patients with treatment of 131 I alone. (author)

  10. Quantum dust magnetosonic waves with spin and exchange correlation effects

    Energy Technology Data Exchange (ETDEWEB)

    Maroof, R.; Qamar, A. [Department of Physics, University of Peshawar, Peshawar 25000 (Pakistan); Mushtaq, A. [Department of Physics, Abdul Wali Khan University, Mardan 23200 (Pakistan); National Center for Physics, Shahdra Valley Road, Islamabad 44000 (Pakistan)

    2016-01-15

    Dust magnetosonic waves are studied in degenerate dusty plasmas with spin and exchange correlation effects. Using the fluid equations of magnetoplasma with quantum corrections due to the Bohm potential, temperature degeneracy, spin magnetization energy, and exchange correlation, a generalized dispersion relation is derived. Spin effects are incorporated via spin force and macroscopic spin magnetization current. The exchange-correlation potentials are used, based on the adiabatic local-density approximation, and can be described as a function of the electron density. For three different values of angle, the dispersion relation is reduced to three different modes under the low frequency magnetohydrodynamic assumptions. It is found that the effects of quantum corrections in the presence of dust concentration significantly modify the dispersive properties of these modes. The results are useful for understanding numerous collective phenomena in quantum plasmas, such as those in compact astrophysical objects (e.g., the cores of white dwarf stars and giant planets) and in plasma-assisted nanotechnology (e.g., quantum diodes, quantum free-electron lasers, etc.)

  11. Quantum dust magnetosonic waves with spin and exchange correlation effects

    Science.gov (United States)

    Maroof, R.; Mushtaq, A.; Qamar, A.

    2016-01-01

    Dust magnetosonic waves are studied in degenerate dusty plasmas with spin and exchange correlation effects. Using the fluid equations of magnetoplasma with quantum corrections due to the Bohm potential, temperature degeneracy, spin magnetization energy, and exchange correlation, a generalized dispersion relation is derived. Spin effects are incorporated via spin force and macroscopic spin magnetization current. The exchange-correlation potentials are used, based on the adiabatic local-density approximation, and can be described as a function of the electron density. For three different values of angle, the dispersion relation is reduced to three different modes under the low frequency magnetohydrodynamic assumptions. It is found that the effects of quantum corrections in the presence of dust concentration significantly modify the dispersive properties of these modes. The results are useful for understanding numerous collective phenomena in quantum plasmas, such as those in compact astrophysical objects (e.g., the cores of white dwarf stars and giant planets) and in plasma-assisted nanotechnology (e.g., quantum diodes, quantum free-electron lasers, etc.).

  12. Plasma treatment: A Novel Medical Application

    International Nuclear Information System (INIS)

    Boonyawan, Dheerawan

    2015-01-01

    Cold atmospheric plasma (CAP) for the medical treatment is a new field in plasma application, called plasma medicine. CAP contrains mix of excited atoms and molecules, UV photons, charged particles as well as reactive oxygen species (ROS) and reactive nitrogen species (RNS). Typical species in air CAPs are O 3 , OH, N x , and HNO x . Two cold atomospheric plasma devices were utiized (either in an indirect or a direct way) for the treatment of physiologically healthy volunterrs, The results show that CAP is effective againts chronic wound infections and/ or for skin treatment in clinical trials. The current developments in this field have fuelled the hope that CAP could be, and interesting new therapeutic apptoach in the treatment of cancer.

  13. Information and consulting center in plasma technologies

    International Nuclear Information System (INIS)

    Vizireanu, S.; Aldea, E.; Mitu, B.; Dinescu, G.

    2001-01-01

    instrumentation and equipment category the most important types of devices used in plasma technologies are described, as for instance, plasma sources (RF, DC, pulsed), vacuum pumps and gauges, methods and programs for computer monitoring and control of plasma systems. In the plasma diagnostics category the most used techniques of spectral and probe investigations are presented. They are not only described, but examples and programs are given, which can be used for spectra simulation (atomic and molecular), for obtaining the rotational and vibrational temperatures, for determination of the electron temperatures and densities in plasma. The main plasma technologies described in the web page are the surface modification by cold plasma, surface cleaning and ashing, plasma polymerization, plasma etching, ion plating, deposition of thin films by sputtering and evaporation, etc. Among them, the technologies developed at the National Institute of Laser, Plasma and Radiation Physics are detailed: deposition of thin films by thermionic vacuum arc; deposition of thin films by sputtering; deposition of carbon based coatings by CVD RF expanding plasma; hard coatings and wear resistant surfaces by plasma nitridation and carburization. The centre web page is under completion with a discussion list allowing easy exchange of ideas, questions and answers. An active offer and service request, accomplished via electronic mail, will be set up. The Centre facilitates a permanent contact between suppliers and customers, which establishes the basis to develop as intermediary of services and products in the plasma technology field. (authors)

  14. Ion exchange technology assessment report

    International Nuclear Information System (INIS)

    Duhn, E.F.

    1992-01-01

    In the execution of its charter, the SRS Ion Exchange Technology Assessment Team has determined that ion exchange (IX) technology has evolved to the point where it should now be considered as a viable alternative to the SRS reference ITP/LW/PH process. The ion exchange media available today offer the ability to design ion exchange processing systems tailored to the unique physical and chemical properties of SRS soluble HLW's. The technical assessment of IX technology and its applicability to the processing of SRS soluble HLW has demonstrated that IX is unquestionably a viable technology. A task team was chartered to evaluate the technology of ion exchange and its potential for replacing the present In-Tank Precipitation and proposed Late Wash processes to remove Cs, Sr, and Pu from soluble salt solutions at the Savannah River Site. This report documents the ion exchange technology assessment and conclusions of the task team

  15. The role of the extracellular matrix in tissue distribution of macromolecules in normal and pathological tissues: potential therapeutic consequences.

    Science.gov (United States)

    Wiig, Helge; Gyenge, Christina; Iversen, Per Ole; Gullberg, Donald; Tenstad, Olav

    2008-05-01

    The interstitial space is a dynamic microenvironment that consists of interstitial fluid and structural molecules of the extracellular matrix, such as glycosaminoglycans (hyaluronan and proteoglycans) and collagen. Macromolecules can distribute in the interstitium only in those spaces unoccupied by structural components, a phenomenon called interstitial exclusion. The exclusion phenomenon has direct consequences for plasma volume regulation. Early studies have assigned a major role to collagen as an excluding agent that accounts for the sterical (geometrical) exclusion. More recently, it has been shown that the contribution of negatively charged glycosaminoglycans might also be significant, resulting in an additional electrostatical exclusion effect. This charge effect may be of importance for drug uptake and suggests that either the glycosaminoglycans or the net charge of macromolecular substances to be delivered may be targeted to increase the available volume and uptake of macromolecular therapeutic agents in tumor tissue. Here, we provide an overview of the structural components of the interstitium and discuss the importance the sterical and electrostatical components have on the dynamics of transcapillary fluid exchange.

  16. Data Exchange Protocol in Repsail

    Directory of Open Access Journals (Sweden)

    Gucma Maciej

    2017-12-01

    Full Text Available Article presents implantation and theoretical considerations of data exchange protocol developed for the RepSail project, where main objective was design and building innovative hybrid yacht. One of problems during the design process was improper functioning of data exchange protocols that were available in the commercially available devices to mention navigation purpose NMEA183 or 2000 as well as automation dedicated ones (CAN and similar. Author shows the basis of the dedicated format of exchange for in board devices.

  17. Developing bulk exchange spring magnets

    Science.gov (United States)

    Mccall, Scott K.; Kuntz, Joshua D.

    2017-06-27

    A method of making a bulk exchange spring magnet by providing a magnetically soft material, providing a hard magnetic material, and producing a composite of said magnetically soft material and said hard magnetic material to make the bulk exchange spring magnet. The step of producing a composite of magnetically soft material and hard magnetic material is accomplished by electrophoretic deposition of the magnetically soft material and the hard magnetic material to make the bulk exchange spring magnet.

  18. Can Exchange Rates Be Predicted?

    OpenAIRE

    Siriwutiset, Trin

    2007-01-01

    Foreign exchange rates produce significant impacts on both the macroeconomic and microeconomic scale. Countries� government and multinational companies have been seeking ways to stabilize the exchange rates for a few decades. However, there is no perfect consensus on methods to control and stabilize the exchange rates. In fact, there are several occasions in history where turbulence movements caused crisis in the economies. There are several factors that are identified by economis...

  19. Towards automatic exchange of information

    OpenAIRE

    Oberson, Xavier

    2015-01-01

    This article describes the various steps that led towards automatic exchange of information as the global standard and the issues that remain to be solved. First, the various competing models of exchange information, such as Double Tax Treaty (DTT), TIEA's, FATCA or UE Directives are described with a view to show how they interact between themselves. Second, the so-called Rubik Strategy is summarized and compared with an automatic exchange of information (AEOI). The third part then describes ...

  20. Exchange rate smoothing in Hungary

    OpenAIRE

    Karádi, Péter

    2005-01-01

    The paper proposes a structural empirical model capable of examining exchange rate smoothing in the small, open economy of Hungary. The framework assumes the existence of an unobserved and changing implicit exchange rate target. The central bank is assumed to use interest rate policy to obtain this preferred rate in the medium term, while market participants are assumed to form rational expectations about this target and influence exchange rates accordingly. The paper applies unobserved varia...