WorldWideScience

Sample records for therapeutic equivalency

  1. Therapeutic equivalence and pharmacokinetics of generic tacrolimus formulation in de novo kidney transplant patients.

    Science.gov (United States)

    Min, Sang-Il; Ha, Jongwon; Kim, Yon Su; Ahn, Sang Hyun; Park, Taejin; Park, Dae Do; Kim, Suh Min; Min, Seung-Kee; Hong, Hyejin; Ahn, Curie; Kim, Sang Joon

    2013-12-01

    There is a growing concern about the therapeutic equivalence of the generic tacrolimus formulation (GEN Tacrolimus) to the reference tacrolimus (REF Tacrolimus) in solid organ transplantation. A prospective, randomized study of 126 de novo renal transplant patients was conducted to compare the efficacy, safety and pharmacokinetic (PK) profiles between GEN tacrolimus (n = 63) and REF tacrolimus (n = 63). The PK of tacrolimus was evaluated on Day 10 and 6 months under steady-state condition. Crossover study was carried out in 66 patients at 6 months. On Day 10, 117 patients completed PK profiles (54 GEN tacrolimus and 63 REF tacrolimus) and GEN tacrolimus showed comparable C(0) (9.8 ± 2.5 versus 9.7 ± 3.0 ng/mL, P = 0.80) but significantly higher dose-normalized C(max) (309.1 ± 191.9 versus 192.5 ± 95.2 ng/mL/mg/kg, P PK profiles evaluated at 9 months showed that generic substitution also resulted in an 'early and high C(max)'. Efficacy and safety data were comparable over the 9-month study period. Therapeutic equivalence and the PK of GEN tacrolimus should be evaluated in patients undergoing de novo renal transplantation.

  2. Determination of the dose equivalents due to neutrons produced during therapeutic irradiations with a Varian CLINAC 2500

    International Nuclear Information System (INIS)

    Carrillo, Ricardo E.

    1991-01-01

    This experiment it was designed to quantify that so important it is the dose equivalent deposited by the neutron flow that is generated by photonuclear reactions during therapeutic irradiations with X rays of produced high-energy for an accelerator Varian CLINAC 2500. This accelerator type is routinely used in the Department of Radiotherapy of the Hospital of the University of Wisconsin, E.U. The equivalent dose was measured in diverse towns of the room of irradiations using the activation of thin sheets of gold put in the center of plastic recipients full with water. In general, the recipients were 1 m or more than the floor and at distances still bigger than the walls. The irradiations were made using photons with the highest energy that you can select with this team - 24 MeV. The due equivalent dose to neutrons taken place here by the energy photons used they were measured and reported. (author)

  3. Challenges and opportunities in establishing scientific and regulatory standards for determining therapeutic equivalence of modified-release products: Workshop summary report.

    Science.gov (United States)

    Chen, Mei-Ling; Shah, Vinod P; Ganes, Derek; Midha, Kamal K; Caro, James; Nambiar, Prabu; Rocci, Mario L; Thombre, Avinash G; Abrahamsson, Bertil; Conner, Dale; Davit, Barbara; Fackler, Paul; Farrell, Colm; Gupta, Suneel; Katz, Russell; Mehta, Mehul; Preskorn, Sheldon H; Sanderink, Gerard; Stavchansky, Salomon; Temple, Robert; Wang, Yaning; Winkle, Helen; Yu, Lawrence

    2010-09-01

    Modified-release (MR) products are complex dosage forms designed to release drug in a controlled manner to achieve the desired efficacy and safety profiles. Inappropriate control of drug release from such products may result in reduced efficacy or increased toxicity. This paper is a summary report of the American Association of Pharmaceutical Scientists, International Pharmaceutical Federation, and Product Quality Research Institute workshop titled "Challenges and Opportunities in Establishing Scientific and Regulatory Standards for Assuring Therapeutic Equivalence of Modified Release Products", held October 1-2, 2009, in Baltimore, Maryland. The workshop provided an opportunity for pharmaceutical scientists from academia, industry, and regulatory agencies to discuss current regulatory expectations and industry practices for evaluating the pharmaceutical equivalence and bioequivalence of oral MR products. In the case of conventional monophasic MR formulations, the current regulatory approaches and criteria for bioequivalence evaluation were considered adequate for the assessment of therapeutic equivalence and inter-changeability of drug products. Additional measures may occasionally be needed to determine the bioequivalence of multiphasic MR products. The metric of partial AUC proposed by the US Food and Drug Administration received broad support as an additional measure for evaluating bioequivalence of multiphasic MR products designed to have a rapid onset of drug action followed by sustained response. The cutoff for partial AUCs may be based on the pharmacokinetic/pharmacodynamic or pharmacokinetic/ response characteristics of the products under examination. If the new metric is highly variable, the bioequivalence limits may be set based on the known within-subject variability for the reference product. The current regulatory approaches and criteria for bioequivalence evaluation were considered adequate for the assessment of therapeutic equivalence and

  4. Relevance of various animal models of human infections to establish therapeutic equivalence of a generic product of piperacillin/tazobactam.

    Science.gov (United States)

    Agudelo, Maria; Rodriguez, Carlos A; Zuluaga, Andres F; Vesga, Omar

    2015-02-01

    After demonstrating with diverse intravenous antibacterials that pharmaceutical equivalence (PE) does not predict therapeutic equivalence, we tested a single generic product of piperacillin/tazobactam (TZP) in terms of PE, pharmacokinetics and in vitro/vivo pharmacodynamics against several pathogens in neutropenic mouse thigh, lung and brain infection models. A generic product was compared head-to-head against the innovator. PE was evaluated by microbiological assay. Single-dose serum pharmacokinetics were determined in infected mice, and the MIC/MBC were determined by broth microdilution. In vivo experiments were done in a blind fashion. Reproducibility was tested on different days using different infecting organisms and animal models. Neutropenic MPF mice were infected in the thighs with Staphylococcus aureus GRP-0057 or Pseudomonas aeruginosa PA01 and in the lungs or brain with Klebsiella pneumoniae ATCC 10031. Treatment started 2h (thigh and brain) or 14 h (lung) after infection and was administered every 3h over 24h (thigh and lung) or 48 h (brain). Both products exhibited the same MIC/MBC against each strain, yielded overlaid curves in the microbiological assay (P>0.21) and were bioequivalent (IC90 83-117% for AUC test/reference ratio). In vivo, the generic product and innovator were again undistinguishable in all models and against the different bacterial pathogens involved. The relevance of these neutropenic murine models of infection was established by demonstrating their accuracy to predict the biological response following simultaneous treatment with a generic product or the innovator of TZP. Therapeutic equivalence of the generic product was proved in every model and against different pathogens. Copyright © 2014 Elsevier B.V. and the International Society of Chemotherapy. All rights reserved.

  5. Approved Drug Products with Therapuetic Equivalence Evaluations (Orange Book)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The publication Approved Drug Products with Therapeutic Equivalence Evaluations (the List, commonly known as the Orange Book) identifies drug products approved on...

  6. THERAPEUTIC EQUIVALENCE OF ORIGINAL CLOPIDOGREL (PLAVIX AND ITS GENERIC (EGITROMB. RESULTS OF COMPARATIVE RANDOMIZED CROSS-OVER BLIND STUDY

    Directory of Open Access Journals (Sweden)

    V. V. Yakusevich

    2011-01-01

    Full Text Available Aim. To study therapeutic equivalence (efficacy, safety and tolerability of original clopidogrel (Plavix and its generic (Egitromb in patients of high cardiovascular risk. Material and methods. Thirty one patients with coronary heart disease and indications for clopidogrel therapy were involved into the randomized cross-over blind study. Half of the patients received original clopidogrel (75 mg daily during the first 2 weeks and then they received generic clopidogrel in the same dose during next 2 weeks. Another half of the patients received the drugs in reverse order. Antiplatelet activity of Plavix and Egitromb was estimated by effects on ADP-induced platelet aggregation initially and after 2 weeks of treatment with each drug. Study blinding was provided by the following approach: doctors of cardiology clinic performed clinical monitoring and drug distribution; coded blood samples for platelet aggregation assessment were studied in independent laboratory of thrombosis; statistical data analysis was performed by biostatistics expert in other research center. Results. 2-week therapy with each drug led to a significant decrease of ADP-induced platelet aggregation which remained low after switching from original drug to generic and vice versa. Aggregation dynamics did not depend on the first administered drug. There were no significant differences between aggregation changes as a result of treatment with original or generic drug. No one adverse event was observed in association with both drugs therapy. Conclusion. Generic drug Egitromb (Egis, Hungary and original clopidogrel Plavix (Sanofi-Aventis, France have equivalent antiplatelet effect.

  7. Chemical equivalence assessment of three brands of ...

    African Journals Online (AJOL)

    Assay for content of active ingredients is a critical test of drug quality; failure to meet up the standard for content of active ingredients will result to sub therapeutic quantities. Three brands (A, B and C) of carbamazepine were assayed to determine their chemical equivalence as well as their anticonvulsant activities. This was ...

  8. Evaluation of a tissue equivalent ionization chamber in X-ray beams

    Energy Technology Data Exchange (ETDEWEB)

    Perini, Ana Paula; Neves, Lucio Pereira; Santos, William de Souza; Caldas, Linda V.E., E-mail: aperini@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Frimaio, Audrew [Seal Technology Ind. Com. Ltda, Sao Paulo, SP (Brazil); Costa, Paulo R. [Universidade de Sao Paulo (USP/IF), Sao Paulo, SP (Brazil). Inst. de Fisica

    2014-07-01

    Tissue equivalent materials present a variety of uses, including routine quality assurance and quality control programs in both diagnostic and therapeutic physics. They are frequently used in research facilities to measure doses delivered to patients undergoing various clinical procedures. This work presents the development and evaluation of a tissue equivalent ionization chamber, with a sensitive volume of 2.3 cm{sup 3}, for routine use in X-rays beams. This ionization chamber was developed at the Calibration Laboratory/IPEN. The new tissue equivalent material was developed at the Physics Institute of the University of Sao Paulo. In order to evaluate the dosimetric performance of the new ionization chamber, several tests described by international standards were undertaken, and all results were within the recommended limits. (author)

  9. Evaluation of a tissue equivalent ionization chamber in X-ray beams

    International Nuclear Information System (INIS)

    Perini, Ana Paula; Neves, Lucio Pereira; Santos, William de Souza; Caldas, Linda V.E.; Frimaio, Audrew; Costa, Paulo R.

    2014-01-01

    Tissue equivalent materials present a variety of uses, including routine quality assurance and quality control programs in both diagnostic and therapeutic physics. They are frequently used in research facilities to measure doses delivered to patients undergoing various clinical procedures. This work presents the development and evaluation of a tissue equivalent ionization chamber, with a sensitive volume of 2.3 cm 3 , for routine use in X-rays beams. This ionization chamber was developed at the Calibration Laboratory/IPEN. The new tissue equivalent material was developed at the Physics Institute of the University of Sao Paulo. In order to evaluate the dosimetric performance of the new ionization chamber, several tests described by international standards were undertaken, and all results were within the recommended limits. (author)

  10. Biological equivalence between LDR and PDR in cervical cancer: multifactor analysis using the linear-quadratic model.

    Science.gov (United States)

    Couto, José Guilherme; Bravo, Isabel; Pirraco, Rui

    2011-09-01

    The purpose of this work was the biological comparison between Low Dose Rate (LDR) and Pulsed Dose Rate (PDR) in cervical cancer regarding the discontinuation of the afterloading system used for the LDR treatments at our Institution since December 2009. In the first phase we studied the influence of the pulse dose and the pulse time in the biological equivalence between LDR and PDR treatments using the Linear Quadratic Model (LQM). In the second phase, the equivalent dose in 2 Gy/fraction (EQD(2)) for the tumor, rectum and bladder in treatments performed with both techniques was evaluated and statistically compared. All evaluated patients had stage IIB cervical cancer and were treated with External Beam Radiotherapy (EBRT) plus two Brachytherapy (BT) applications. Data were collected from 48 patients (26 patients treated with LDR and 22 patients with PDR). In the analyses of the influence of PDR parameters in the biological equivalence between LDR and PDR treatments (Phase 1), it was calculated that if the pulse dose in PDR was kept equal to the LDR dose rate, a small the-rapeutic loss was expected. If the pulse dose was decreased, the therapeutic window became larger, but a correction in the prescribed dose was necessary. In PDR schemes with 1 hour interval between pulses, the pulse time did not influence significantly the equivalent dose. In the comparison between the groups treated with LDR and PDR (Phase 2) we concluded that they were not equivalent, because in the PDR group the total EQD(2) for the tumor, rectum and bladder was smaller than in the LDR group; the LQM estimated that a correction in the prescribed dose of 6% to 10% was ne-cessary to avoid therapeutic loss. A correction in the prescribed dose was necessary; this correction should be achieved by calculating the PDR dose equivalent to the desired LDR total dose.

  11. Determination of the dose equivalents due to neutrons produced during therapeutic irradiations with a Varian CLINAC 2500; Determinacion de la dosis equivalente debida a neutrones producidos durante irradiaciones terapeuticas con un Varian CLINAC 2500

    Energy Technology Data Exchange (ETDEWEB)

    Carrillo, Ricardo E [Centro de Investigacion y de Estudios Avanzados del IPN, Unidad Merida, Yucatan (Mexico)

    1991-07-01

    This experiment it was designed to quantify that so important it is the dose equivalent deposited by the neutron flow that is generated by photonuclear reactions during therapeutic irradiations with X rays of produced high-energy for an accelerator Varian CLINAC 2500. This accelerator type is routinely used in the Department of Radiotherapy of the Hospital of the University of Wisconsin, E.U. The equivalent dose was measured in diverse towns of the room of irradiations using the activation of thin sheets of gold put in the center of plastic recipients full with water. In general, the recipients were 1 m or more than the floor and at distances still bigger than the walls. The irradiations were made using photons with the highest energy that you can select with this team - 24 MeV. The due equivalent dose to neutrons taken place here by the energy photons used they were measured and reported. (author)

  12. Cone-beam computed tomography imaging: therapeutic staff dose during chemoembolisation procedure

    International Nuclear Information System (INIS)

    Paul, Jijo; Vogl, Thomas J; Chacko, Annamma; Mbalisike, Emmanuel C

    2014-01-01

    Cone-beam computed tomography (CBCT) imaging is an important requirement to perform real-time therapeutic image-guided procedures on patients. The purpose of this study is to estimate the personal-dose-equivalent and annual-personal-dose from CBCT imaging during transarterial chemoembolisation (TACE). Therapeutic staff doses (therapeutic and assistant physician) were collected during 200 patient (65  ±  15 years, range: 40–86) CBCT examinations over six months. Absorbed doses were assessed using thermo-luminescent dosimeters during patient hepatic TACE therapy. We estimated personal-dose-equivalent (PDE) and annual-personal-dose (APD) from absorbed dose based on international atomic energy agency protocol. APD for therapeutic procedure was calculated (therapeutic physician: 5.6 mSv; assistant physician: 5.08 mSv) based on institutional work load. Regarding PDE, the hands of the staff members received a greater dose compared to other anatomical locations (therapeutic physician: 56 mSv, 72 mSv; assistant physician: 12 mSv, 14 mSv). Annual radiation doses to the eyes and hands of the staff members were lower compared to the prescribed limits by the International Commission on Radiological Protection (ICRP). PDE and APD of both therapeutic staff members were within the recommended ICRP-103 annual limit. Dose to the assistant physician was lower than the dose to the therapeutic physician during imaging. Annual radiation doses to eye-lenses and hands of both staff members were lower than prescribed limits. (paper)

  13. Out-of-Field Dose Equivalents Delivered by Passively Scattered Therapeutic Proton Beams for Clinically Relevant Field Configurations

    International Nuclear Information System (INIS)

    Wroe, Andrew; Clasie, Ben; Kooy, Hanne; Flanz, Jay; Schulte, Reinhard; Rosenfeld, Anatoly

    2009-01-01

    Purpose: Microdosimetric measurements were performed at Massachusetts General Hospital, Boston, MA, to assess the dose equivalent external to passively delivered proton fields for various clinical treatment scenarios. Methods and Materials: Treatment fields evaluated included a prostate cancer field, cranial and spinal medulloblastoma fields, ocular melanoma field, and a field for an intracranial stereotactic treatment. Measurements were completed with patient-specific configurations of clinically relevant treatment settings using a silicon-on-insulator microdosimeter placed on the surface of and at various depths within a homogeneous Lucite phantom. The dose equivalent and average quality factor were assessed as a function of both lateral displacement from the treatment field edge and distance downstream of the beam's distal edge. Results: Dose-equivalent value range was 8.3-0.3 mSv/Gy (2.5-60-cm lateral displacement) for a typical prostate cancer field, 10.8-0.58 mSv/Gy (2.5-40-cm lateral displacement) for the cranial medulloblastoma field, 2.5-0.58 mSv/Gy (5-20-cm lateral displacement) for the spinal medulloblastoma field, and 0.5-0.08 mSv/Gy (2.5-10-cm lateral displacement) for the ocular melanoma field. Measurements of external field dose equivalent for the stereotactic field case showed differences as high as 50% depending on the modality of beam collimation. Average quality factors derived from this work ranged from 2-7, with the value dependent on the position within the phantom in relation to the primary beam. Conclusions: This work provides a valuable and clinically relevant comparison of the external field dose equivalents for various passively scattered proton treatment fields

  14. Politico-economic equivalence

    DEFF Research Database (Denmark)

    Gonzalez Eiras, Martin; Niepelt, Dirk

    2015-01-01

    Traditional "economic equivalence'' results, like the Ricardian equivalence proposition, define equivalence classes over exogenous policies. We derive "politico-economic equivalence" conditions that apply in environments where policy is endogenous and chosen sequentially. A policy regime and a st......Traditional "economic equivalence'' results, like the Ricardian equivalence proposition, define equivalence classes over exogenous policies. We derive "politico-economic equivalence" conditions that apply in environments where policy is endogenous and chosen sequentially. A policy regime...... their use in the context of several applications, relating to social security reform, tax-smoothing policies and measures to correct externalities....

  15. Challenges of therapeutic substitution of drugs for economic reasons: focus on CVD prevention.

    Science.gov (United States)

    Johnston, Atholl

    2010-04-01

    Healthcare systems throughout the world are under increasing pressure to control and minimise costs. The substitution of initially-prescribed drugs with cheaper equivalents is an obvious option which presents a rapid and visible means to reduce these costs. Whether the substitution improves patient and/or population outcomes must be appraised and this paper highlights the conditions under which therapeutic substitution may require additional thought and consideration. In this paper, some of the medical evidence and the regulatory environment for and against the three types of therapeutic substitution - generic, within-class and between-class - are discussed. This article is not an exhaustive review of the literature, but captures some of the key clinical, pharmacological, economic, policy and ethical issues regarding generic and therapeutic substitution. Search criteria of the most commonly used terms, i.e. therapeutic substitution, switching, interchange, and bioequivalence, were applied to Embase, PubMed and Google Scholar to identify relevant publications. Although population studies support therapeutic substitution in principle, there is evidence that substitution may not always result in therapeutic equivalence in individual patients, with the consequent potential for greater risks of decreased efficacy and/or increased safety concerns. Factors such as patient choice and therapeutic equivalence also play an important role in the effectiveness of the treatment and overall management of the patient. The pan-European regulatory environment provides another contradiction, encouraging widespread cost containment through reduction in drug acquisition costs, while simultaneously promoting an increased role for patients in defining and managing their own treatment. There is a strong rationale for careful management in some patients with cardiovascular disease. Treatment decisions should be transparent and based on strong clinical evidence. If not, drug substitution on

  16. What is correct: equivalent dose or dose equivalent

    International Nuclear Information System (INIS)

    Franic, Z.

    1994-01-01

    In Croatian language some physical quantities in radiation protection dosimetry have not precise names. Consequently, in practice either terms in English or mathematical formulas are used. The situation is even worse since the Croatian language only a limited number of textbooks, reference books and other papers are available. This paper compares the concept of ''dose equivalent'' as outlined in International Commission on Radiological Protection (ICRP) recommendations No. 26 and newest, conceptually different concept of ''equivalent dose'' which is introduced in ICRP 60. It was found out that Croatian terminology is both not uniform and unprecise. For the term ''dose equivalent'' was, under influence of Russian and Serbian languages, often used as term ''equivalent dose'' even from the point of view of ICRP 26 recommendations, which was not justified. Unfortunately, even now, in Croatia the legal unit still ''dose equivalent'' defined as in ICRP 26, but the term used for it is ''equivalent dose''. Therefore, in Croatian legislation a modified set of quantities introduced in ICRP 60, should be incorporated as soon as possible

  17. Water-equivalent one-dimensional scintillating fiber-optic dosimeter for measuring therapeutic photon beam

    International Nuclear Information System (INIS)

    Moon, Jinsoo; Won Jang, Kyoung; Jae Yoo, Wook; Han, Ki-Tek; Park, Jang-Yeon; Lee, Bongsoo

    2012-01-01

    In this study, we fabricated a one-dimensional scintillating fiber-optic dosimeter, which consists of 9 scintillating fiber-optic dosimeters, septa, and PMMA blocks for measuring surface and percentage depth doses of a therapeutic photon beam. Each dosimeter embedded in the 1-D scintillating fiber-optic dosimeter is composed of square type organic scintillators and plastic optical fibers. Also black PVC films are used as septa to minimize cross-talk between the scintillating fiber-optic dosimeters. To construct a dosimeter system, a 1-D scintillating fiber-optic dosimeter and a CMOS image sensor were combined with 20 m-length plastic optical fibers. Using the dosimeter system, we measured surface and percentage depth doses of 6 and 15 MV photon beams and compared the results with those of EBT films and an ionization chamber. - Highlights: ► Fabrication of a one-dimensional scintillating fiber-optic dosimeter. ► The one-dimensional scintillating fiber-optic dosimeter has 9 scintillating fiber-optic dosimeters. ► Measurements of surface and percentage depth doses of a therapeutic photon beam. ► The results were compared with those of EBT films and an ionization chamber.

  18. Equivalent Lagrangians

    International Nuclear Information System (INIS)

    Hojman, S.

    1982-01-01

    We present a review of the inverse problem of the Calculus of Variations, emphasizing the ambiguities which appear due to the existence of equivalent Lagrangians for a given classical system. In particular, we analyze the properties of equivalent Lagrangians in the multidimensional case, we study the conditions for the existence of a variational principle for (second as well as first order) equations of motion and their solutions, we consider the inverse problem of the Calculus of Variations for singular systems, we state the ambiguities which emerge in the relationship between symmetries and conserved quantities in the case of equivalent Lagrangians, we discuss the problems which appear in trying to quantize classical systems which have different equivalent Lagrangians, we describe the situation which arises in the study of equivalent Lagrangians in field theory and finally, we present some unsolved problems and discussion topics related to the content of this article. (author)

  19. Implementation of an Analytical Model for Leakage Neutron Equivalent Dose in a Proton Radiotherapy Planning System

    Energy Technology Data Exchange (ETDEWEB)

    Eley, John [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Blvd., Houston, TX 77030 (United States); Graduate School of Biomedical Sciences, The University of Texas, 6767 Bertner Ave., Houston, TX 77030 (United States); Newhauser, Wayne, E-mail: newhauser@lsu.edu [Department of Physics and Astronomy, Louisiana State University and Agricultural and Mechanical College, 202 Nicholson Hall, Tower Drive, Baton Rouge, LA 70803 (United States); Mary Bird Perkins Cancer Center, 4950 Essen Lane, Baton Rouge, LA 70809 (United States); Homann, Kenneth; Howell, Rebecca [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Blvd., Houston, TX 77030 (United States); Graduate School of Biomedical Sciences, The University of Texas, 6767 Bertner Ave., Houston, TX 77030 (United States); Schneider, Christopher [Department of Physics and Astronomy, Louisiana State University and Agricultural and Mechanical College, 202 Nicholson Hall, Tower Drive, Baton Rouge, LA 70803 (United States); Mary Bird Perkins Cancer Center, 4950 Essen Lane, Baton Rouge, LA 70809 (United States); Durante, Marco; Bert, Christoph [GSI Helmholtzzentrum für Schwerionenforschung, Planckstr. 1, Darmstadt 64291 (Germany)

    2015-03-11

    Equivalent dose from neutrons produced during proton radiotherapy increases the predicted risk of radiogenic late effects. However, out-of-field neutron dose is not taken into account by commercial proton radiotherapy treatment planning systems. The purpose of this study was to demonstrate the feasibility of implementing an analytical model to calculate leakage neutron equivalent dose in a treatment planning system. Passive scattering proton treatment plans were created for a water phantom and for a patient. For both the phantom and patient, the neutron equivalent doses were small but non-negligible and extended far beyond the therapeutic field. The time required for neutron equivalent dose calculation was 1.6 times longer than that required for proton dose calculation, with a total calculation time of less than 1 h on one processor for both treatment plans. Our results demonstrate that it is feasible to predict neutron equivalent dose distributions using an analytical dose algorithm for individual patients with irregular surfaces and internal tissue heterogeneities. Eventually, personalized estimates of neutron equivalent dose to organs far from the treatment field may guide clinicians to create treatment plans that reduce the risk of late effects.

  20. Biological equivalence between LDR and PDR in cervical cancer: multifactor analysis using the linear-quadratic model

    Directory of Open Access Journals (Sweden)

    José Guilherme Couto

    2011-09-01

    Full Text Available Purpose: The purpose of this work was the biological comparison between Low Dose Rate (LDR and Pulsed DoseRate (PDR in cervical cancer regarding the discontinuation of the afterloading system used for the LDR treatments atour Institution since December 2009. Material and methods: In the first phase we studied the influence of the pulse dose and the pulse time in the biologicalequivalence between LDR and PDR treatments using the Linear Quadratic Model (LQM. In the second phase,the equivalent dose in 2 Gy/fraction (EQD2 for the tumor, rectum and bladder in treatments performed with both techniqueswas evaluated and statistically compared. All evaluated patients had stage IIB cervical cancer and were treatedwith External Beam Radiotherapy (EBRT plus two Brachytherapy (BT applications. Data were collected from 48 patients(26 patients treated with LDR and 22 patients with PDR. Results: In the analyses of the influence of PDR parameters in the biological equivalence between LDR and PDRtreatments (Phase 1, it was calculated that if the pulse dose in PDR was kept equal to the LDR dose rate, a small therapeuticloss was expected. If the pulse dose was decreased, the therapeutic window became larger, but a correction inthe prescribed dose was necessary. In PDR schemes with 1 hour interval between pulses, the pulse time did not influencesignificantly the equivalent dose. In the comparison between the groups treated with LDR and PDR (Phase 2 weconcluded that they were not equivalent, because in the PDR group the total EQD2 for the tumor, rectum and bladderwas smaller than in the LDR group; the LQM estimated that a correction in the prescribed dose of 6% to 10% was ne -cessary to avoid therapeutic loss. Conclusions: A correction in the prescribed dose was necessary; this correction should be achieved by calculatingthe PDR dose equivalent to the desired LDR total dose.

  1. Determination of dose equivalent with tissue-equivalent proportional counters

    International Nuclear Information System (INIS)

    Dietze, G.; Schuhmacher, H.; Menzel, H.G.

    1989-01-01

    Low pressure tissue-equivalent proportional counters (TEPC) are instruments based on the cavity chamber principle and provide spectral information on the energy loss of single charged particles crossing the cavity. Hence such detectors measure absorbed dose or kerma and are able to provide estimates on radiation quality. During recent years TEPC based instruments have been developed for radiation protection applications in photon and neutron fields. This was mainly based on the expectation that the energy dependence of their dose equivalent response is smaller than that of other instruments in use. Recently, such instruments have been investigated by intercomparison measurements in various neutron and photon fields. Although their principles of measurements are more closely related to the definition of dose equivalent quantities than those of other existing dosemeters, there are distinct differences and limitations with respect to the irradiation geometry and the determination of the quality factor. The application of such instruments for measuring ambient dose equivalent is discussed. (author)

  2. Therapeutic irradiation and brain injury

    International Nuclear Information System (INIS)

    Sheline, G.E.; Wara, W.M.; Smith, V.

    1980-01-01

    This is a review and reanalysis of the literature on adverse effects of therapeutic irradiation on the brain. Reactions have been grouped and considered according to time of appearance. The emphasis of the analysis is on delayed reactions, especially those that occur from a few months to several years after irradiation. All dose specifications were converted into equivalent megavoltage rads. The data were analyzed in terms of total dose, overall treatment time and number of treatment fractions. Also discussed were acute radiation reactions, early delayed radiation reactions, somnolence and leukoencephalopathy post-irradiation/chemotherapy and combined effects of radiation and chemotherapy

  3. Conotoxins that confer therapeutic possibilities

    KAUST Repository

    Essack, Magbubah

    2012-06-04

    Cone snails produce a distinctive repertoire of venom peptides that are used both as a defense mechanism and also to facilitate the immobilization and digestion of prey. These peptides target a wide variety of voltage- and ligand-gated ion channels, which make them an invaluable resource for studying the properties of these ion channels in normal and diseased states, as well as being a collection of compounds of potential pharmacological use in their own right. Examples include the United States Food and Drug Administration (FDA) approved pharmaceutical drug, Ziconotide (Prialt; Elan Pharmaceuticals, Inc.) that is the synthetic equivalent of the naturally occurring ?-conotoxin MVIIA, whilst several other conotoxins are currently being used as standard research tools and screened as potential therapeutic drugs in pre-clinical or clinical trials. These developments highlight the importance of driving conotoxin-related research. A PubMed query from 1 January 2007 to 31 August 2011 combined with hand-curation of the retrieved articles allowed for the collation of 98 recently identified conotoxins with therapeutic potential which are selectively discussed in this review. Protein sequence similarity analysis tentatively assigned uncharacterized conotoxins to predicted functional classes. Furthermore, conotoxin therapeutic potential for neurodegenerative disorders (NDD) was also inferred. 2012 by the authors; licensee MDPI.

  4. Conotoxins that confer therapeutic possibilities

    KAUST Repository

    Essack, Magbubah; Bajic, Vladimir B.; Archer, John A.C.

    2012-01-01

    Cone snails produce a distinctive repertoire of venom peptides that are used both as a defense mechanism and also to facilitate the immobilization and digestion of prey. These peptides target a wide variety of voltage- and ligand-gated ion channels, which make them an invaluable resource for studying the properties of these ion channels in normal and diseased states, as well as being a collection of compounds of potential pharmacological use in their own right. Examples include the United States Food and Drug Administration (FDA) approved pharmaceutical drug, Ziconotide (Prialt; Elan Pharmaceuticals, Inc.) that is the synthetic equivalent of the naturally occurring ?-conotoxin MVIIA, whilst several other conotoxins are currently being used as standard research tools and screened as potential therapeutic drugs in pre-clinical or clinical trials. These developments highlight the importance of driving conotoxin-related research. A PubMed query from 1 January 2007 to 31 August 2011 combined with hand-curation of the retrieved articles allowed for the collation of 98 recently identified conotoxins with therapeutic potential which are selectively discussed in this review. Protein sequence similarity analysis tentatively assigned uncharacterized conotoxins to predicted functional classes. Furthermore, conotoxin therapeutic potential for neurodegenerative disorders (NDD) was also inferred. 2012 by the authors; licensee MDPI.

  5. Equivalent Dynamic Models.

    Science.gov (United States)

    Molenaar, Peter C M

    2017-01-01

    Equivalences of two classes of dynamic models for weakly stationary multivariate time series are discussed: dynamic factor models and autoregressive models. It is shown that exploratory dynamic factor models can be rotated, yielding an infinite set of equivalent solutions for any observed series. It also is shown that dynamic factor models with lagged factor loadings are not equivalent to the currently popular state-space models, and that restriction of attention to the latter type of models may yield invalid results. The known equivalent vector autoregressive model types, standard and structural, are given a new interpretation in which they are conceived of as the extremes of an innovating type of hybrid vector autoregressive models. It is shown that consideration of hybrid models solves many problems, in particular with Granger causality testing.

  6. Energy distribution of projectile fragment particles in heavy ion therapeutic beam

    Energy Technology Data Exchange (ETDEWEB)

    Matsufuji, Naruhiro; Tomura, Hiromi; Futami, Yasuyuki [National Inst. of Radiological Sciences, Chiba (Japan)] [and others

    1998-03-01

    Production of fragment particles in a patient`s body is one of important problems for heavy charged particle therapy. It is required to know the yield and the energy spectrum for each fragment element - so called `beam quality` to understand the effect of therapeutic beam precisely. In this study, fragment particles produced by practical therapeutic beam of HIMAC were investigated with using tissue-equivalent material and a detector complex. From the results, fragment particles were well identified by difference of their atomic numbers and the beam quality was derived. Responses of the detectors in this energy region were also researched. (author)

  7. EQUIVALENCE VERSUS NON-EQUIVALENCE IN ECONOMIC TRANSLATION

    Directory of Open Access Journals (Sweden)

    Cristina, Chifane

    2012-01-01

    Full Text Available This paper aims at highlighting the fact that “equivalence” represents a concept worth revisiting and detailing upon when tackling the translation process of economic texts both from English into Romanian and from Romanian into English. Far from being exhaustive, our analysis will focus upon the problems arising from the lack of equivalence at the word level. Consequently, relevant examples from the economic field will be provided to account for the following types of non-equivalence at word level: culturespecific concepts; the source language concept is not lexicalised in the target language; the source language word is semantically complex; differences in physical and interpersonal perspective; differences in expressive meaning; differences in form; differences in frequency and purpose of using specific forms and the use of loan words in the source text. Likewise, we shall illustrate a number of translation strategies necessary to deal with the afore-mentioned cases of non-equivalence: translation by a more general word (superordinate; translation by a more neutral/less expressive word; translation by cultural substitution; translation using a loan word or loan word plus explanation; translation by paraphrase using a related word; translation by paraphrase using unrelated words; translation by omission and translation by illustration.

  8. Radioactive waste equivalence

    International Nuclear Information System (INIS)

    Orlowski, S.; Schaller, K.H.

    1990-01-01

    The report reviews, for the Member States of the European Community, possible situations in which an equivalence concept for radioactive waste may be used, analyses the various factors involved, and suggests guidelines for the implementation of such a concept. Only safety and technical aspects are covered. Other aspects such as commercial ones are excluded. Situations where the need for an equivalence concept has been identified are processes where impurities are added as a consequence of the treatment and conditioning process, the substitution of wastes from similar waste streams due to the treatment process, and exchange of waste belonging to different waste categories. The analysis of factors involved and possible ways for equivalence evaluation, taking into account in particular the chemical, physical and radiological characteristics of the waste package, and the potential risks of the waste form, shows that no simple all-encompassing equivalence formula may be derived. Consequently, a step-by-step approach is suggested, which avoids complex evaluations in the case of simple exchanges

  9. Equivalence principles and electromagnetism

    Science.gov (United States)

    Ni, W.-T.

    1977-01-01

    The implications of the weak equivalence principles are investigated in detail for electromagnetic systems in a general framework. In particular, it is shown that the universality of free-fall trajectories (Galileo weak equivalence principle) does not imply the validity of the Einstein equivalence principle. However, the Galileo principle plus the universality of free-fall rotation states does imply the Einstein principle.

  10. New recommendations for dose equivalent

    International Nuclear Information System (INIS)

    Bengtsson, G.

    1985-01-01

    In its report 39, the International Commission on Radiation Units and Measurements (ICRU), has defined four new quantities for the determination of dose equivalents from external sources: the ambient dose equivalent, the directional dose equivalent, the individual dose equivalent, penetrating and the individual dose equivalent, superficial. The rationale behind these concepts and their practical application are discussed. Reference is made to numerical values of these quantities which will be the subject of a coming publication from the International Commission on Radiological Protection, ICRP. (Author)

  11. Equivalent models of wind farms by using aggregated wind turbines and equivalent winds

    International Nuclear Information System (INIS)

    Fernandez, L.M.; Garcia, C.A.; Saenz, J.R.; Jurado, F.

    2009-01-01

    As a result of the increasing wind farms penetration on power systems, the wind farms begin to influence power system, and therefore the modeling of wind farms has become an interesting research topic. In this paper, new equivalent models of wind farms equipped with wind turbines based on squirrel-cage induction generators and doubly-fed induction generators are proposed to represent the collective behavior on large power systems simulations, instead of using a complete model of wind farms where all the wind turbines are modeled. The models proposed here are based on aggregating wind turbines into an equivalent wind turbine which receives an equivalent wind of the ones incident on the aggregated wind turbines. The equivalent wind turbine presents re-scaled power capacity and the same complete model as the individual wind turbines, which supposes the main feature of the present equivalent models. Two equivalent winds are evaluated in this work: (1) the average wind from the ones incident on the aggregated wind turbines with similar winds, and (2) an equivalent incoming wind derived from the power curve and the wind incident on each wind turbine. The effectiveness of the equivalent models to represent the collective response of the wind farm at the point of common coupling to grid is demonstrated by comparison with the wind farm response obtained from the detailed model during power system dynamic simulations, such as wind fluctuations and a grid disturbance. The present models can be used for grid integration studies of large power system with an important reduction of the model order and the computation time

  12. Physical dose of therapeutic exercises in institutional neck rehabilitation.

    Science.gov (United States)

    Wasenius, Niko; Karapalo, Teppo; Sjögren, Tuulikki; Pekkonen, Mika; Mälkiä, Esko

    2013-03-01

    To determine the intensity and volume of therapeutic exercises during a standard 13-day inpatient neck rehabilitation course in relation to overall physical activity in rehabilitation and everyday life. Cross-sectional study. Subjects (n = 19; 16 women and 3 men; mean age 48.6 years, standard deviation (SD) 6.6) with chronic non-specific neck pain were recruited from two inpatient neck rehabilitation courses. Intensity and volume of therapeutic exercises and physical activity were measured in metabolic equivalents (METs) with an objective measurement device and all-time recall questionnaire. Maximum oxygen uptake was determined in METs (METc) by direct maximal cycle ergometer. Subjects' mean METc was 7.2 METs (SD 1.4) or 25.3 ml/kg/min (SD 4.8). Intensity of all therapeutic exercises was 1.9 METs or 27 %METc (SD 5.1) and volume 7.7 MET-hours/week. Intensity of specific neck and shoulder exercises was 2.0 METs or 28 %METc (SD 5.4) and volume 2.5 MET-hours/week. In addition, subjects were more active in everyday life than in inpatient rehabilitation. The therapeutic exercise dose failed to reach previously reported target values for pain relief. The dose of therapeutic exercises and confounding physical activity should be carefully controlled in pain rehabilitation programmes.

  13. Microdosimetric investigation at the therapeutic proton beam facility of CATANA.

    Science.gov (United States)

    De Nardo, L; Moro, D; Colautti, P; Conte, V; Tornielli, G; Cuttone, G

    2004-01-01

    Proton beams (62 Mev) are used by the Laboratori Nazionali del Sud of the Italian Institute of Nuclear Physics to treat eye melanoma tumours at the therapeutic facility called CATANA. A cylindrical slim tissue-equivalent proportional counter (TEPC) of 2.7 mm external diameter has been used to compare the radiation quality of two spread-out Bragg peaks (SOBP) at the CATANA proton beam.

  14. Microdosimetric investigation at the therapeutic proton beam facility of Catana

    International Nuclear Information System (INIS)

    De Nardo, L.; Moro, D.; Colautti, P.; Conte, V.; Tornielli, G.; Cuttone, G.

    2004-01-01

    Proton beams (62 Mev) are used by the Laboratori Nazionali del Sud of the Italian Inst. of Nuclear Physics to treat eye melanoma tumours at the therapeutic facility called CATANA. A cylindrical slim tissue-equivalent proportional counter (TEPC) of 2.7 mm external diameter has been used to compare the radiation quality of two spread-out Bragg peaks (SOBP) at the CATANA proton beam. (authors)

  15. Correspondences. Equivalence relations

    International Nuclear Information System (INIS)

    Bouligand, G.M.

    1978-03-01

    We comment on sections paragraph 3 'Correspondences' and paragraph 6 'Equivalence Relations' in chapter II of 'Elements de mathematique' by N. Bourbaki in order to simplify their comprehension. Paragraph 3 exposes the ideas of a graph, correspondence and map or of function, and their composition laws. We draw attention to the following points: 1) Adopting the convention of writting from left to right, the composition law for two correspondences (A,F,B), (U,G,V) of graphs F, G is written in full generality (A,F,B)o(U,G,V) = (A,FoG,V). It is not therefore assumed that the co-domain B of the first correspondence is identical to the domain U of the second (EII.13 D.7), (1970). 2) The axiom of choice consists of creating the Hilbert terms from the only relations admitting a graph. 3) The statement of the existence theorem of a function h such that f = goh, where f and g are two given maps having the same domain (of definition), is completed if h is more precisely an injection. Paragraph 6 considers the generalisation of equality: First, by 'the equivalence relation associated with a map f of a set E identical to (x is a member of the set E and y is a member of the set E and x:f = y:f). Consequently, every relation R(x,y) which is equivalent to this is an equivalence relation in E (symmetrical, transitive, reflexive); then R admits a graph included in E x E, etc. Secondly, by means of the Hilbert term of a relation R submitted to the equivalence. In this last case, if R(x,y) is separately collectivizing in x and y, theta(x) is not the class of objects equivalent to x for R (EII.47.9), (1970). The interest of bringing together these two subjects, apart from this logical order, resides also in the fact that the theorem mentioned in 3) can be expressed by means of the equivalence relations associated with the functions f and g. The solutions of the examples proposed reveal their simplicity [fr

  16. Calculation methods for determining dose equivalent

    International Nuclear Information System (INIS)

    Endres, G.W.R.; Tanner, J.E.; Scherpelz, R.I.; Hadlock, D.E.

    1987-11-01

    A series of calculations of neutron fluence as a function of energy in an anthropomorphic phantom was performed to develop a system for determining effective dose equivalent for external radiation sources. Critical organ dose equivalents are calculated and effective dose equivalents are determined using ICRP-26 [1] methods. Quality factors based on both present definitions and ICRP-40 definitions are used in the analysis. The results of these calculations are presented and discussed. The effective dose equivalent determined using ICRP-26 methods is significantly smaller than the dose equivalent determined by traditional methods. No existing personnel dosimeter or health physics instrument can determine effective dose equivalent. At the present time, the conversion of dosimeter response to dose equivalent is based on calculations for maximal or ''cap'' values using homogeneous spherical or cylindrical phantoms. The evaluated dose equivalent is, therefore, a poor approximation of the effective dose equivalent as defined by ICRP Publication 26. 3 refs., 2 figs., 1 tab

  17. Effective dose equivalent

    International Nuclear Information System (INIS)

    Huyskens, C.J.; Passchier, W.F.

    1988-01-01

    The effective dose equivalent is a quantity which is used in the daily practice of radiation protection as well as in the radiation hygienic rules as measure for the health risks. In this contribution it is worked out upon which assumptions this quantity is based and in which cases the effective dose equivalent can be used more or less well. (H.W.)

  18. Equivalence relations of AF-algebra extensions

    Indian Academy of Sciences (India)

    In this paper, we consider equivalence relations of *-algebra extensions and describe the relationship between the isomorphism equivalence and the unitary equivalence. We also show that a certain group homomorphism is the obstruction for these equivalence relations to be the same.

  19. Equivalent physical models and formulation of equivalent source layer in high-resolution EEG imaging

    International Nuclear Information System (INIS)

    Yao Dezhong; He Bin

    2003-01-01

    In high-resolution EEG imaging, both equivalent dipole layer (EDL) and equivalent charge layer (ECL) assumed to be located just above the cortical surface have been proposed as high-resolution imaging modalities or as intermediate steps to estimate the epicortical potential. Presented here are the equivalent physical models of these two equivalent source layers (ESL) which show that the strength of EDL is proportional to the surface potential of the layer when the outside of the layer is filled with an insulator, and that the strength of ECL is the normal current of the layer when the outside is filled with a perfect conductor. Based on these equivalent physical models, closed solutions of ECL and EDL corresponding to a dipole enclosed by a spherical layer are given. These results provide the theoretical basis of ESL applications in high-resolution EEG mapping

  20. Equivalent physical models and formulation of equivalent source layer in high-resolution EEG imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yao Dezhong [School of Life Science and Technology, University of Electronic Science and Technology of China, Chengdu City, 610054, Sichuan Province (China); He Bin [The University of Illinois at Chicago, IL (United States)

    2003-11-07

    In high-resolution EEG imaging, both equivalent dipole layer (EDL) and equivalent charge layer (ECL) assumed to be located just above the cortical surface have been proposed as high-resolution imaging modalities or as intermediate steps to estimate the epicortical potential. Presented here are the equivalent physical models of these two equivalent source layers (ESL) which show that the strength of EDL is proportional to the surface potential of the layer when the outside of the layer is filled with an insulator, and that the strength of ECL is the normal current of the layer when the outside is filled with a perfect conductor. Based on these equivalent physical models, closed solutions of ECL and EDL corresponding to a dipole enclosed by a spherical layer are given. These results provide the theoretical basis of ESL applications in high-resolution EEG mapping.

  1. Testing statistical hypotheses of equivalence

    CERN Document Server

    Wellek, Stefan

    2010-01-01

    Equivalence testing has grown significantly in importance over the last two decades, especially as its relevance to a variety of applications has become understood. Yet published work on the general methodology remains scattered in specialists' journals, and for the most part, it focuses on the relatively narrow topic of bioequivalence assessment.With a far broader perspective, Testing Statistical Hypotheses of Equivalence provides the first comprehensive treatment of statistical equivalence testing. The author addresses a spectrum of specific, two-sided equivalence testing problems, from the

  2. Information Leakage from Logically Equivalent Frames

    Science.gov (United States)

    Sher, Shlomi; McKenzie, Craig R. M.

    2006-01-01

    Framing effects are said to occur when equivalent frames lead to different choices. However, the equivalence in question has been incompletely conceptualized. In a new normative analysis of framing effects, we complete the conceptualization by introducing the notion of information equivalence. Information equivalence obtains when no…

  3. 21 CFR 26.9 - Equivalence determination.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Equivalence determination. 26.9 Section 26.9 Food... Specific Sector Provisions for Pharmaceutical Good Manufacturing Practices § 26.9 Equivalence determination... document insufficient evidence of equivalence, lack of opportunity to assess equivalence or a determination...

  4. Editorial: New operational dose equivalent quantities

    International Nuclear Information System (INIS)

    Harvey, J.R.

    1985-01-01

    The ICRU Report 39 entitled ''Determination of Dose Equivalents Resulting from External Radiation Sources'' is briefly discussed. Four new operational dose equivalent quantities have been recommended in ICRU 39. The 'ambient dose equivalent' and the 'directional dose equivalent' are applicable to environmental monitoring and the 'individual dose equivalent, penetrating' and the 'individual dose equivalent, superficial' are applicable to individual monitoring. The quantities should meet the needs of day-to-day operational practice, while being acceptable to those concerned with metrological precision, and at the same time be used to give effective control consistent with current perceptions of the risks associated with exposure to ionizing radiations. (U.K.)

  5. Development of a tissue-engineered human oral mucosa equivalent based on an acellular allogeneic dermal matrix: a preliminary report of clinical application to burn wounds.

    Science.gov (United States)

    Iida, Takuya; Takami, Yoshihiro; Yamaguchi, Ryo; Shimazaki, Shuji; Harii, Kiyonori

    2005-01-01

    Tissue-engineered skin equivalents composed of epidermal and dermal components have been widely investigated for coverage of full-thickness skin defects. We developed a tissue-engineered oral mucosa equivalent based on an acellular allogeneic dermal matrix and investigated its characteristics. We also tried and assessed its preliminary clinical application. Human oral mucosal keratinocytes were separated from a piece of oral mucosa and cultured in a chemically-defined medium. The keratinocytes were seeded on to the acellular allogeneic dermal matrix and cultured. Histologically, the mucosa equivalent had a well-stratified epithelial layer. Immunohistochemical study showed that it was similar to normal oral mucosa. We applied this equivalent in one case with an extensive burn wound. The equivalent was transplanted three weeks after the harvest of the patient's oral mucosa and about 30% of the graft finally survived. We conclude that this new oral mucosa equivalent could become a therapeutic option for the treatment of extensive burns.

  6. Mixed field dose equivalent measuring instruments

    International Nuclear Information System (INIS)

    Brackenbush, L.W.; McDonald, J.C.; Endres, G.W.R.; Quam, W.

    1985-01-01

    In the past, separate instruments have been used to monitor dose equivalent from neutrons and gamma rays. It has been demonstrated that it is now possible to measure simultaneously neutron and gamma dose with a single instrument, the tissue equivalent proportional counter (TEPC). With appropriate algorithms dose equivalent can also be determined from the TEPC. A simple ''pocket rem meter'' for measuring neutron dose equivalent has already been developed. Improved algorithms for determining dose equivalent for mixed fields are presented. (author)

  7. Characterization of revenue equivalence

    NARCIS (Netherlands)

    Heydenreich, B.; Müller, R.; Uetz, Marc Jochen; Vohra, R.

    2009-01-01

    The property of an allocation rule to be implementable in dominant strategies by a unique payment scheme is called revenue equivalence. We give a characterization of revenue equivalence based on a graph theoretic interpretation of the incentive compatibility constraints. The characterization holds

  8. The therapeutic relationship in e-therapy for mental health: a systematic review.

    Science.gov (United States)

    Sucala, Madalina; Schnur, Julie B; Constantino, Michael J; Miller, Sarah J; Brackman, Emily H; Montgomery, Guy H

    2012-08-02

    E-therapy is defined as a licensed mental health care professional providing mental health services via e-mail, video conferencing, virtual reality technology, chat technology, or any combination of these. The use of e-therapy has been rapidly expanding in the last two decades, with growing evidence suggesting that the provision of mental health services over the Internet is both clinically efficacious and cost effective. Yet there are still unanswered concerns about e-therapy, including whether it is possible to develop a successful therapeutic relationship over the Internet in the absence of nonverbal cues. Our objective in this study was to systematically review the therapeutic relationship in e-therapy. We searched PubMed, PsycINFO, and CINAHL through August 2011. Information on study methods and results was abstracted independently by the authors using a standardized form. From the 840 reviewed studies, only 11 (1.3%) investigated the therapeutic relationship. The majority of the reviewed studies were focused on the therapeutic alliance-a central element of the therapeutic relationship. Although the results do not allow firm conclusions, they indicate that e-therapy seems to be at least equivalent to face-to-face therapy in terms of therapeutic alliance, and that there is a relationship between the therapeutic alliance and e-therapy outcome. Overall, the current literature on the role of therapeutic relationship in e-therapy is scant, and much more research is needed to understand the therapeutic relationship in online environments.

  9. Design of therapeutic vaccines as a novel antibody therapy for cardiovascular diseases.

    Science.gov (United States)

    Nakagami, Hironori

    2017-09-01

    Vaccines are primarily used worldwide as a preventive medicine for infectious diseases and have recently been applied to cancer. We and others have developed therapeutic vaccines designed for cardiovascular diseases that are notably different from previous vaccines. In the case of cancer vaccines, a specific protein in cancer cells is a target antigen, and the activation of cytotoxic T cells (CTL) is required to kill and remove the antigen-presenting cancer cells. Our therapeutic vaccines work against hypertension by targeting angiotensin II (Ang II) as the antigen, which is an endogenous hormone. Therapeutic vaccines must avoid CTL activation and induce the blocking antibodies for Ang II. The goal of our therapeutic vaccine for cardiovascular diseases is to induce the specific antibody response toward the target protein without inducing T-cell or antibody-mediated inflammation through the careful selection of the target antigen, carrier protein and adjuvants. The goal of our therapeutic vaccine is similar to that of antibody therapy. Recently, multiple antibody-based drugs have been developed for cancer, immune-related diseases, and dyslipidemia, which are efficient but expensive. If the effect of a therapeutic vaccine is nearly equivalent to antibody therapy as an alternative approach, the lower medical cost and improvement in drug adherence can be advantages of therapeutic vaccines. In this review, we will describe our concept of therapeutic vaccines for cardiovascular diseases and the future directions of therapeutic vaccines as novel antibody therapies. Copyright © 2017. Published by Elsevier Ltd.

  10. Characterization of Revenue Equivalence

    NARCIS (Netherlands)

    Heydenreich, Birgit; Müller, Rudolf; Uetz, Marc Jochen; Vohra, Rakesh

    2008-01-01

    The property of an allocation rule to be implementable in dominant strategies by a unique payment scheme is called \\emph{revenue equivalence}. In this paper we give a characterization of revenue equivalence based on a graph theoretic interpretation of the incentive compatibility constraints. The

  11. Quantification of the equivalence principle

    International Nuclear Information System (INIS)

    Epstein, K.J.

    1978-01-01

    Quantitative relationships illustrate Einstein's equivalence principle, relating it to Newton's ''fictitious'' forces arising from the use of noninertial frames, and to the form of the relativistic time dilatation in local Lorentz frames. The equivalence principle can be interpreted as the equivalence of general covariance to local Lorentz covariance, in a manner which is characteristic of Riemannian and pseudo-Riemannian geometries

  12. The principle of equivalence reconsidered: assessing the relevance of the principle of equivalence in prison medicine.

    Science.gov (United States)

    Jotterand, Fabrice; Wangmo, Tenzin

    2014-01-01

    In this article we critically examine the principle of equivalence of care in prison medicine. First, we provide an overview of how the principle of equivalence is utilized in various national and international guidelines on health care provision to prisoners. Second, we outline some of the problems associated with its applications, and argue that the principle of equivalence should go beyond equivalence to access and include equivalence of outcomes. However, because of the particular context of the prison environment, third, we contend that the concept of "health" in equivalence of health outcomes needs conceptual clarity; otherwise, it fails to provide a threshold for healthy states among inmates. We accomplish this by examining common understandings of the concepts of health and disease. We conclude our article by showing why the conceptualization of diseases as clinical problems provides a helpful approach in the delivery of health care in prison.

  13. On the operator equivalents

    International Nuclear Information System (INIS)

    Grenet, G.; Kibler, M.

    1978-06-01

    A closed polynomial formula for the qth component of the diagonal operator equivalent of order k is derived in terms of angular momentum operators. The interest in various fields of molecular and solid state physics of using such a formula in connection with symmetry adapted operator equivalents is outlined

  14. 78 FR 67360 - Ambient Air Monitoring Reference and Equivalent Methods: Designation of Five New Equivalent Methods

    Science.gov (United States)

    2013-11-12

    ... Methods: Designation of Five New Equivalent Methods AGENCY: Office of Research and Development; Environmental Protection Agency (EPA). ACTION: Notice of the designation of five new equivalent methods for...) has designated, in accordance with 40 CFR Part 53, five new equivalent methods, one for measuring...

  15. 77 FR 60985 - Ambient Air Monitoring Reference and Equivalent Methods: Designation of Three New Equivalent Methods

    Science.gov (United States)

    2012-10-05

    ... Methods: Designation of Three New Equivalent Methods AGENCY: Environmental Protection Agency. ACTION: Notice of the designation of three new equivalent methods for monitoring ambient air quality. SUMMARY... equivalent methods, one for measuring concentrations of PM 2.5 , one for measuring concentrations of PM 10...

  16. Investigation of Equivalent Circuit for PEMFC Assessment

    International Nuclear Information System (INIS)

    Myong, Kwang Jae

    2011-01-01

    Chemical reactions occurring in a PEMFC are dominated by the physical conditions and interface properties, and the reactions are expressed in terms of impedance. The performance of a PEMFC can be simply diagnosed by examining the impedance because impedance characteristics can be expressed by an equivalent electrical circuit. In this study, the characteristics of a PEMFC are assessed using the AC impedance and various equivalent circuits such as a simple equivalent circuit, equivalent circuit with a CPE, equivalent circuit with two RCs, and equivalent circuit with two CPEs. It was found in this study that the characteristics of a PEMFC could be assessed using impedance and an equivalent circuit, and the accuracy was highest for an equivalent circuit with two CPEs

  17. Logically automorphically equivalent knowledge bases

    OpenAIRE

    Aladova, Elena; Plotkin, Tatjana

    2017-01-01

    Knowledge bases theory provide an important example of the field where applications of universal algebra and algebraic logic look very natural, and their interaction with practical problems arising in computer science might be very productive. In this paper we study the equivalence problem for knowledge bases. Our interest is to find out how the informational equivalence is related to the logical description of knowledge. Studying various equivalences of knowledge bases allows us to compare d...

  18. Therapeutic communication in nursing students: A Walker & Avant concept analysis

    Science.gov (United States)

    Abdolrahimi, Mahbobeh; Ghiyasvandian, Shahrzad; Zakerimoghadam, Masoumeh; Ebadi, Abbas

    2017-01-01

    Background and aim Therapeutic communication, the fundamental component of nursing, is a complex concept. Furthermore, the poor encounters between nursing student and patient demonstrate the necessity of instruction regarding therapeutic communication. The aim of this study was to define and clarify this important concept for including this subject in the nursing curriculum with more emphasis. Methods A literature search was conducted using keywords such as “nursing student”, “patient” and “therapeutic communication” and Persian-equivalent words in Persian databases (including Magiran and Medlib) and English databases (including PubMed, ScienceDirect, Scopus and ProQuest) without time limitation. After extracting concept definitions and determining characteristic features, therapeutic communication in nursing students was defined. Then, sample cases, antecedents, consequences and empirical referents of concept were determined. Results After assessing 30 articles, therapeutic communication defining attributes were as follows: “an important means in building interpersonal relationships”, “a process of information transmission”, “an important clinical competency”, “a structure with two different sections” and “a significant tool in patient centered care”. Furthermore, theoretical and clinical education and receiving educators’ feedback regarding therapeutic communication were considered as antecedents of the concept. Improving physical and psychological health status of patient as well as professional development of nursing students were identified as consequences of the concept. Conclusion Nursing instructors can use these results in order to teach and evaluate therapeutic communication in nursing students and train qualified nurses. Also, nursing students may apply the results to improve the quality of their interactions with patients, perform their various duties and meet patients’ diverse needs. PMID:28979730

  19. 46 CFR 175.540 - Equivalents.

    Science.gov (United States)

    2010-10-01

    ... Safety Management (ISM) Code (IMO Resolution A.741(18)) for the purpose of determining that an equivalent... Organization (IMO) “Code of Safety for High Speed Craft” as an equivalent to compliance with applicable...

  20. Wijsman Orlicz Asymptotically Ideal -Statistical Equivalent Sequences

    Directory of Open Access Journals (Sweden)

    Bipan Hazarika

    2013-01-01

    in Wijsman sense and present some definitions which are the natural combination of the definition of asymptotic equivalence, statistical equivalent, -statistical equivalent sequences in Wijsman sense. Finally, we introduce the notion of Cesaro Orlicz asymptotically -equivalent sequences in Wijsman sense and establish their relationship with other classes.

  1. The performance of low pressure tissue-equivalent chambers and a new method for parameterising the dose equivalent

    International Nuclear Information System (INIS)

    Eisen, Y.

    1986-01-01

    The performance of Rossi-type spherical tissue-equivalent chambers with equivalent diameters between 0.5 μm and 2 μm was tested experimentally using monoenergetic and polyenergetic neutron sources in the energy region of 10 keV to 14.5 MeV. In agreement with theoretical predictions both chambers failed to provide LET information at low neutron energies. A dose equivalent algorithm was derived that utilises the event distribution but does not attempt to correlate event size with LET. The algorithm was predicted theoretically and confirmed by experiment. The algorithm that was developed determines the neutron dose equivalent, from the data of the 0.5 μm chamber, to better than +-20% over the energy range of 30 keV to 14.5 MeV. The same algorithm also determines the dose equivalent from the data of the 2 μm chamber to better than +-20% over the energy range of 60 keV to 14.5 MeV. The efficiency of the chambers is 33 counts per μSv, or equivalently about 10 counts s -1 per mSv.h -1 . This efficiency enables the measurement of dose equivalent rates above 1 mSv.h -1 for an integration period of 3 s. Integrated dose equivalents can be measured as low as 1 μSv. (author)

  2. Equivalence in Bilingual Lexicography: Criticism and Suggestions*

    Directory of Open Access Journals (Sweden)

    Herbert Ernst Wiegand

    2011-10-01

    Full Text Available

    Abstract: A reminder of general problems in the formation of terminology, as illustrated by theGerman Äquivalence (Eng. equivalence and äquivalent (Eng. equivalent, is followed by a critical discussionof the concept of equivalence in contrastive lexicology. It is shown that especially the conceptof partial equivalence is contradictory in its different manifestations. Consequently attemptsare made to give a more precise indication of the concept of equivalence in the metalexicography,with regard to the domain of the nominal lexicon. The problems of especially the metalexicographicconcept of partial equivalence as well as that of divergence are fundamentally expounded.In conclusion the direction is indicated to find more appropriate metalexicographic versions of theconcept of equivalence.

    Keywords: EQUIVALENCE, LEXICOGRAPHIC EQUIVALENT, PARTIAL EQUIVALENCE,CONGRUENCE, DIVERGENCE, CONVERGENCE, POLYDIVERGENCE, SYNTAGM-EQUIVALENCE,ZERO EQUIVALENCE, CORRESPONDENCE

    Abstrakt: Äquivalenz in der zweisprachigen Lexikographie: Kritik und Vorschläge.Nachdem an allgemeine Probleme der Begriffsbildung am Beispiel von dt. Äquivalenzund dt. äquivalent erinnert wurde, wird zunächst auf Äquivalenzbegriffe in der kontrastiven Lexikologiekritisch eingegangen. Es wird gezeigt, dass insbesondere der Begriff der partiellen Äquivalenzin seinen verschiedenen Ausprägungen widersprüchlich ist. Sodann werden Präzisierungenzu den Äquivalenzbegriffen in der Metalexikographie versucht, die sich auf den Bereich der Nennlexikbeziehen. Insbesondere der metalexikographische Begriff der partiellen Äquivalenz sowie derder Divergenz werden grundsätzlich problematisiert. In welche Richtung man gehen kann, umangemessenere metalexikographische Fassungen des Äquivalenzbegriffs zu finden, wird abschließendangedeutet.

    Stichwörter: ÄQUIVALENZ, LEXIKOGRAPHISCHES ÄQUIVALENT, PARTIELLE ÄQUIVALENZ,KONGRUENZ, DIVERGENZ, KONVERGENZ, POLYDIVERGENZ

  3. Equivalent brain SPECT perfusion changes underlying therapeutic efficiency in pharmacoresistant depression using either high-frequency left or low-frequency right prefrontal rTMS.

    Science.gov (United States)

    Richieri, Raphaëlle; Boyer, Laurent; Padovani, Romain; Adida, Marc; Colavolpe, Cécile; Mundler, Olivier; Lançon, Christophe; Guedj, Eric

    2012-12-03

    Functional neuroimaging studies have suggested similar mechanisms underlying antidepressant effects of distinct therapeutics. This study aimed to determine and compare functional brain patterns underlying the antidepressant response of 2 distinct protocols of repetitive transcranial magnetic stimulation (rTMS). 99mTc-ECD SPECT was performed before and after rTMS of dorsolateral prefrontal cortex in 61 drug-resistant right-handed patients with major depression, using high frequency (10Hz) left-side stimulation in 33 patients, and low frequency (1Hz) right-side stimulation in 28 patients. Efficiency of rTMS response was defined as at least 50% reduction of the baseline Beck Depression Inventory score. We compared the whole-brain voxel-based brain SPECT changes in perfusion after rTMS, between responders and non-responders in the whole sample (pleft- and right-stimulation. Before rTMS, the left- and right-prefrontal stimulation groups did not differ from clinical data and brain SPECT perfusion. rTMS efficiency (evaluated on % of responders) was statistically equivalent in the two groups of patients. In the whole-group of responder patients, a perfusion decrease was found after rTMS, in comparison to non-responders, within the left perirhinal cortex (BA35, BA36). This result was secondarily confirmed separately in the two subgroups, i.e. after either left stimulation (p=0.017) or right stimulation (pbrain functional changes associated to antidepressive efficiency, consisting to a remote brain limbic activity decrease within the left perirhinal cortex. However, these results will have to be confirmed in a double-blind randomized trial using a sham control group. Copyright © 2012 Elsevier Inc. All rights reserved.

  4. Structuring polymers for delivery of DNA-based therapeutics: updated insights.

    Science.gov (United States)

    Gupta, Madhu; Tiwari, Shailja; Vyas, Suresh

    2012-01-01

    Gene therapy offers greater opportunities for treating numerous incurable diseases from genetic disorders, infections, and cancer. However, development of appropriate delivery systems could be one of the most important factors to overcome numerous biological barriers for delivery of various therapeutic molecules. A number of nonviral polymer-mediated vectors have been developed for DNA delivery and offer the potential to surmount the associated problems of their viral counterpart. To address the concerns associated with safety issues, a wide range of polymeric vectors are available and have been utilized successfully to deliver their therapeutics in vivo. Today's research is mainly focused on the various natural or synthetic polymer-based delivery carriers that protect the DNA molecule from degradation, which offer specific targeting to the desired cells after systemic administration, have transfection efficiencies equivalent to virus-mediated gene delivery, and have long-term gene expression through sustained-release mechanisms. This review explores an updated overview of different nonviral polymeric delivery system for delivery of DNA-based therapeutics. These polymeric carriers have been evaluated in vitro and in vivo and are being utilized in various stages of clinical evaluation. Continued research and understanding of the principles of polymer-based gene delivery systems will enable us to develop new and efficient delivery systems for the delivery of DNA-based therapeutics to achieve the goal of efficacious and specific gene therapy for a vast array of clinical disorders as the therapeutic solutions of tomorrow.

  5. SAPONIFICATION EQUIVALENT OF DASAMULA TAILA

    OpenAIRE

    Saxena, R. B.

    1994-01-01

    Saponification equivalent values of Dasamula taila are very useful for the technical and analytical work. It gives the mean molecular weight of the glycerides and acids present in Dasamula Taila. Saponification equivalent values of Dasamula taila are reported in different packings.

  6. Saponification equivalent of dasamula taila.

    Science.gov (United States)

    Saxena, R B

    1994-07-01

    Saponification equivalent values of Dasamula taila are very useful for the technical and analytical work. It gives the mean molecular weight of the glycerides and acids present in Dasamula Taila. Saponification equivalent values of Dasamula taila are reported in different packings.

  7. Some spectral equivalences between Schroedinger operators

    International Nuclear Information System (INIS)

    Dunning, C; Hibberd, K E; Links, J

    2008-01-01

    Spectral equivalences of the quasi-exactly solvable sectors of two classes of Schroedinger operators are established, using Gaudin-type Bethe ansatz equations. In some instances the results can be extended leading to full isospectrality. In this manner we obtain equivalences between PT-symmetric problems and Hermitian problems. We also find equivalences between some classes of Hermitian operators

  8. Gauge equivalence of the Gross Pitaevskii equation and the equivalent Heisenberg spin chain

    Science.gov (United States)

    Radha, R.; Kumar, V. Ramesh

    2007-11-01

    In this paper, we construct an equivalent spin chain for the Gross-Pitaevskii equation with quadratic potential and exponentially varying scattering lengths using gauge equivalence. We have then generated the soliton solutions for the spin components S3 and S-. We find that the spin solitons for S3 and S- can be compressed for exponentially growing eigenvalues while they broaden out for decaying eigenvalues.

  9. A study on lead equivalent

    International Nuclear Information System (INIS)

    Lin Guanxin

    1991-01-01

    A study on the rules in which the lead equivalent of lead glass changes with the energy of X rays or γ ray is described. The reason of this change is discussed and a new testing method of lead equivalent is suggested

  10. Analytical and numerical construction of equivalent cables.

    Science.gov (United States)

    Lindsay, K A; Rosenberg, J R; Tucker, G

    2003-08-01

    The mathematical complexity experienced when applying cable theory to arbitrarily branched dendrites has lead to the development of a simple representation of any branched dendrite called the equivalent cable. The equivalent cable is an unbranched model of a dendrite and a one-to-one mapping of potentials and currents on the branched model to those on the unbranched model, and vice versa. The piecewise uniform cable, with a symmetrised tri-diagonal system matrix, is shown to represent the canonical form for an equivalent cable. Through a novel application of the Laplace transform it is demonstrated that an arbitrary branched model of a dendrite can be transformed to the canonical form of an equivalent cable. The characteristic properties of the equivalent cable are extracted from the matrix for the transformed branched model. The one-to-one mapping follows automatically from the construction of the equivalent cable. The equivalent cable is used to provide a new procedure for characterising the location of synaptic contacts on spinal interneurons.

  11. Establishing Substantial Equivalence: Transcriptomics

    Science.gov (United States)

    Baudo, María Marcela; Powers, Stephen J.; Mitchell, Rowan A. C.; Shewry, Peter R.

    Regulatory authorities in Western Europe require transgenic crops to be substantially equivalent to conventionally bred forms if they are to be approved for commercial production. One way to establish substantial equivalence is to compare the transcript profiles of developing grain and other tissues of transgenic and conventionally bred lines, in order to identify any unintended effects of the transformation process. We present detailed protocols for transcriptomic comparisons of developing wheat grain and leaf material, and illustrate their use by reference to our own studies of lines transformed to express additional gluten protein genes controlled by their own endosperm-specific promoters. The results show that the transgenes present in these lines (which included those encoding marker genes) did not have any significant unpredicted effects on the expression of endogenous genes and that the transgenic plants were therefore substantially equivalent to the corresponding parental lines.

  12. On uncertainties in definition of dose equivalent

    International Nuclear Information System (INIS)

    Oda, Keiji

    1995-01-01

    The author has entertained always the doubt that in a neutron field, if the measured value of the absorbed dose with a tissue equivalent ionization chamber is 1.02±0.01 mGy, may the dose equivalent be taken as 10.2±0.1 mSv. Should it be 10.2 or 11, but the author considers it is 10 or 20. Even if effort is exerted for the precision measurement of absorbed dose, if the coefficient being multiplied to it is not precise, it is meaningless. [Absorbed dose] x [Radiation quality fctor] = [Dose equivalent] seems peculiar. How accurately can dose equivalent be evaluated ? The descriptions related to uncertainties in the publications of ICRU and ICRP are introduced, which are related to radiation quality factor, the accuracy of measuring dose equivalent and so on. Dose equivalent shows the criterion for the degree of risk, or it is considered only as a controlling quantity. The description in the ICRU report 1973 related to dose equivalent and its unit is cited. It was concluded that dose equivalent can be considered only as the absorbed dose being multiplied by a dimensionless factor. The author presented the questions. (K.I.)

  13. Quantifying the Combined Effect of Radiation Therapy and Hyperthermia in Terms of Equivalent Dose Distributions

    International Nuclear Information System (INIS)

    Kok, H. Petra; Crezee, Johannes; Franken, Nicolaas A.P.; Stalpers, Lukas J.A.; Barendsen, Gerrit W.; Bel, Arjan

    2014-01-01

    Purpose: To develop a method to quantify the therapeutic effect of radiosensitization by hyperthermia; to this end, a numerical method was proposed to convert radiation therapy dose distributions with hyperthermia to equivalent dose distributions without hyperthermia. Methods and Materials: Clinical intensity modulated radiation therapy plans were created for 15 prostate cancer cases. To simulate a clinically relevant heterogeneous temperature distribution, hyperthermia treatment planning was performed for heating with the AMC-8 system. The temperature-dependent parameters α (Gy −1 ) and β (Gy −2 ) of the linear–quadratic model for prostate cancer were estimated from the literature. No thermal enhancement was assumed for normal tissue. The intensity modulated radiation therapy plans and temperature distributions were exported to our in-house-developed radiation therapy treatment planning system, APlan, and equivalent dose distributions without hyperthermia were calculated voxel by voxel using the linear–quadratic model. Results: The planned average tumor temperatures T90, T50, and T10 in the planning target volume were 40.5°C, 41.6°C, and 42.4°C, respectively. The planned minimum, mean, and maximum radiation therapy doses were 62.9 Gy, 76.0 Gy, and 81.0 Gy, respectively. Adding hyperthermia yielded an equivalent dose distribution with an extended 95% isodose level. The equivalent minimum, mean, and maximum doses reflecting the radiosensitization by hyperthermia were 70.3 Gy, 86.3 Gy, and 93.6 Gy, respectively, for a linear increase of α with temperature. This can be considered similar to a dose escalation with a substantial increase in tumor control probability for high-risk prostate carcinoma. Conclusion: A model to quantify the effect of combined radiation therapy and hyperthermia in terms of equivalent dose distributions was presented. This model is particularly instructive to estimate the potential effects of interaction from different treatment

  14. AN OVERVIEW OF BIOLOGICS: SCIENCE BEHIND PROTEIN THERAPEUTICS

    Directory of Open Access Journals (Sweden)

    Inderjeet Kaur

    2012-12-01

    Full Text Available Biosimilars or ‘follow-on biologics’ are new biopharmaceutical agents that are ‘similar’ but not identical to a reference biopharmaceutical product. Biosimilars are considered ‘comparable’ to the reference product, but this does not ensure therapeutic equivalence. Inherent differences between biosimilars may produce dissimilarities in clinical efficacy, safety, and immunogenicity. Therefore accurate measurement and characterization of these differences and absolute quantification of biosimilars is the significant requirement at present. Mass spectrometry coupled with high performance liquid chromatography offers the most sensitive and accurate solution for this. This review discusses the potential strategies for the absolute quantification of biosimilars using mass spectrometry.

  15. Equivalent Simplification Method of Micro-Grid

    OpenAIRE

    Cai Changchun; Cao Xiangqin

    2013-01-01

    The paper concentrates on the equivalent simplification method for the micro-grid system connection into distributed network. The equivalent simplification method proposed for interaction study between micro-grid and distributed network. Micro-grid network, composite load, gas turbine synchronous generation, wind generation are equivalent simplification and parallel connect into the point of common coupling. A micro-grid system is built and three phase and single phase grounded faults are per...

  16. Chiropractor interaction and treatment equivalence in a pilot randomized controlled trial

    DEFF Research Database (Denmark)

    Salsbury, Stacie A; DeVocht, James W; Hondras, Maria

    2014-01-01

    -parametric statistics were calculated. RESULTS: The trial ran from January 2010 to October 2011. We analyzed 111 complete video-recordings (54 active, 57 sham). Chiropractor interactions differed between the treatment groups in 7 categories. Active participants received more interactions with clinical information (8 vs....... 4) or explanations (3.5 vs. 1) than sham participants within the therapeutic domain. Active participants received more directions (63 vs. 58) and adjusting instrument thrusts (41.5 vs. 23) in the procedural domain and more optimistic (2.5 vs. 0) or neutral (7.5 vs. 5) outcome statements...... aimed to: 1) develop an instrument to assess practitioner-patient interactions; 2) determine the equivalence of a chiropractor's verbal interactions and treatment delivery for participants allocated to active or sham chiropractic groups; and 3) describe the perceptions of a treatment-masked evaluator...

  17. Equivalence relations and the reinforcement contingency.

    Science.gov (United States)

    Sidman, M

    2000-07-01

    Where do equivalence relations come from? One possible answer is that they arise directly from the reinforcement contingency. That is to say, a reinforcement contingency produces two types of outcome: (a) 2-, 3-, 4-, 5-, or n-term units of analysis that are known, respectively, as operant reinforcement, simple discrimination, conditional discrimination, second-order conditional discrimination, and so on; and (b) equivalence relations that consist of ordered pairs of all positive elements that participate in the contingency. This conception of the origin of equivalence relations leads to a number of new and verifiable ways of conceptualizing equivalence relations and, more generally, the stimulus control of operant behavior. The theory is also capable of experimental disproof.

  18. Equivalence Principle, Higgs Boson and Cosmology

    Directory of Open Access Journals (Sweden)

    Mauro Francaviglia

    2013-05-01

    Full Text Available We discuss here possible tests for Palatini f(R-theories together with their implications for different formulations of the Equivalence Principle. We shall show that Palatini f(R-theories obey the Weak Equivalence Principle and violate the Strong Equivalence Principle. The violations of the Strong Equivalence Principle vanish in vacuum (and purely electromagnetic solutions as well as on short time scales with respect to the age of the universe. However, we suggest that a framework based on Palatini f(R-theories is more general than standard General Relativity (GR and it sheds light on the interpretation of data and results in a way which is more model independent than standard GR itself.

  19. Symmetries of dynamically equivalent theories

    Energy Technology Data Exchange (ETDEWEB)

    Gitman, D.M.; Tyutin, I.V. [Sao Paulo Univ., SP (Brazil). Inst. de Fisica; Lebedev Physics Institute, Moscow (Russian Federation)

    2006-03-15

    A natural and very important development of constrained system theory is a detail study of the relation between the constraint structure in the Hamiltonian formulation with specific features of the theory in the Lagrangian formulation, especially the relation between the constraint structure with the symmetries of the Lagrangian action. An important preliminary step in this direction is a strict demonstration, and this is the aim of the present article, that the symmetry structures of the Hamiltonian action and of the Lagrangian action are the same. This proved, it is sufficient to consider the symmetry structure of the Hamiltonian action. The latter problem is, in some sense, simpler because the Hamiltonian action is a first-order action. At the same time, the study of the symmetry of the Hamiltonian action naturally involves Hamiltonian constraints as basic objects. One can see that the Lagrangian and Hamiltonian actions are dynamically equivalent. This is why, in the present article, we consider from the very beginning a more general problem: how the symmetry structures of dynamically equivalent actions are related. First, we present some necessary notions and relations concerning infinitesimal symmetries in general, as well as a strict definition of dynamically equivalent actions. Finally, we demonstrate that there exists an isomorphism between classes of equivalent symmetries of dynamically equivalent actions. (author)

  20. Calculation methods for determining dose equivalent

    International Nuclear Information System (INIS)

    Endres, G.W.R.; Tanner, J.E.; Scherpelz, R.I.; Hadlock, D.E.

    1988-01-01

    A series of calculations of neutron fluence as a function of energy in an anthropomorphic phantom was performed to develop a system for determining effective dose equivalent for external radiation sources. critical organ dose equivalents are calculated and effective dose equivalents are determined using ICRP-26 methods. Quality factors based on both present definitions and ICRP-40 definitions are used in the analysis. The results of these calculations are presented and discussed

  1. Quality assurance after process changes of the production of a therapeutic antibody.

    Science.gov (United States)

    Brass, J M; Krummen, K; Moll-Kaufmann, C

    1996-12-01

    Process development for the production of a therapeutic humanised antibody is a very complex operation. It involves recombinant genetics, verification of a strong expression system, gene amplification, characterisation of a stable host cell expression system, optimisation and design of the mammalian cell culture fermentation system and development of an efficient recovery process resulting in high yields and product quality. Rapid progress in the field and the wish of some pharmaceutical companies for outsourcing their production are the driving forces for process changes relatively late in the development phase. This literature survey is aimed at identifying the limits of acceptable process changes in up scaling of the fermentation and down stream processing of biopharmaceuticals and defining the demand in production validation to prove product equivalency and identity of the isolated, purified therapeutic antibody.

  2. The one-dimensional normalised generalised equivalence theory (NGET) for generating equivalent diffusion theory group constants for PWR reflector regions

    International Nuclear Information System (INIS)

    Mueller, E.Z.

    1991-01-01

    An equivalent diffusion theory PWR reflector model is presented, which has as its basis Smith's generalisation of Koebke's Equivalent Theory. This method is an adaptation, in one-dimensional slab geometry, of the Generalised Equivalence Theory (GET). Since the method involves the renormalisation of the GET discontinuity factors at nodal interfaces, it is called the Normalised Generalised Equivalence Theory (NGET) method. The advantages of the NGET method for modelling the ex-core nodes of a PWR are summarized. 23 refs

  3. The definition of the individual dose equivalent

    International Nuclear Information System (INIS)

    Ehrlich, Margarete

    1986-01-01

    A brief note examines the choice of the present definition of the individual dose equivalent, the new operational dosimetry quantity for external exposure. The consequences of the use of the individual dose equivalent and the danger facing the individual dose equivalent, as currently defined, are briefly discussed. (UK)

  4. 77 FR 32632 - Ambient Air Monitoring Reference and Equivalent Methods: Designation of Three New Equivalent Methods

    Science.gov (United States)

    2012-06-01

    ... Methods: Designation of Three New Equivalent Methods AGENCY: Environmental Protection Agency. ACTION... accordance with 40 CFR Part 53, three new equivalent methods: One for measuring concentrations of nitrogen... INFORMATION: In accordance with regulations at 40 CFR Part 53, the EPA evaluates various methods for...

  5. Beyond Language Equivalence on Visibly Pushdown Automata

    DEFF Research Database (Denmark)

    Srba, Jiri

    2009-01-01

    We study (bi)simulation-like preorder/equivalence checking on the class of visibly pushdown automata and its natural subclasses visibly BPA (Basic Process Algebra) and visibly one-counter automata. We describe generic methods for proving complexity upper and lower bounds for a number of studied...... preorders and equivalences like simulation, completed simulation, ready simulation, 2-nested simulation preorders/equivalences and bisimulation equivalence. Our main results are that all the mentioned equivalences and preorders are EXPTIME-complete on visibly pushdown automata, PSPACE-complete on visibly...... one-counter automata and P-complete on visibly BPA. Our PSPACE lower bound for visibly one-counter automata improves also the previously known DP-hardness results for ordinary one-counter automata and one-counter nets. Finally, we study regularity checking problems for visibly pushdown automata...

  6. The equivalence problem for LL- and LR-regular grammars

    NARCIS (Netherlands)

    Nijholt, Antinus; Gecsec, F.

    It will be shown that the equivalence problem for LL-regular grammars is decidable. Apart from extending the known result for LL(k) grammar equivalence to LLregular grammar equivalence, we obtain an alternative proof of the decidability of LL(k) equivalence. The equivalence prob]em for LL-regular

  7. Equivalent damage of loads on pavements

    CSIR Research Space (South Africa)

    Prozzi, JA

    2009-05-26

    Full Text Available This report describes a new methodology for the determination of Equivalent Damage Factors (EDFs) of vehicles with multiple axle and wheel configurations on pavements. The basic premise of this new procedure is that "equivalent pavement response...

  8. 7 CFR 1030.54 - Equivalent price.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 9 2010-01-01 2009-01-01 true Equivalent price. 1030.54 Section 1030.54 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Handling Class Prices § 1030.54 Equivalent price. See § 1000.54. ...

  9. Equivalence in Ventilation and Indoor Air Quality

    Energy Technology Data Exchange (ETDEWEB)

    Sherman, Max; Walker, Iain; Logue, Jennifer

    2011-08-01

    We ventilate buildings to provide acceptable indoor air quality (IAQ). Ventilation standards (such as American Society of Heating, Refrigerating, and Air-Conditioning Enginners [ASHRAE] Standard 62) specify minimum ventilation rates without taking into account the impact of those rates on IAQ. Innovative ventilation management is often a desirable element of reducing energy consumption or improving IAQ or comfort. Variable ventilation is one innovative strategy. To use variable ventilation in a way that meets standards, it is necessary to have a method for determining equivalence in terms of either ventilation or indoor air quality. This study develops methods to calculate either equivalent ventilation or equivalent IAQ. We demonstrate that equivalent ventilation can be used as the basis for dynamic ventilation control, reducing peak load and infiltration of outdoor contaminants. We also show that equivalent IAQ could allow some contaminants to exceed current standards if other contaminants are more stringently controlled.

  10. Orientifold Planar Equivalence: The Chiral Condensate

    DEFF Research Database (Denmark)

    Armoni, Adi; Lucini, Biagio; Patella, Agostino

    2008-01-01

    The recently introduced orientifold planar equivalence is a promising tool for solving non-perturbative problems in QCD. One of the predictions of orientifold planar equivalence is that the chiral condensates of a theory with $N_f$ flavours of Dirac fermions in the symmetric (or antisymmetric...

  11. 7 CFR 1005.54 - Equivalent price.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 9 2010-01-01 2009-01-01 true Equivalent price. 1005.54 Section 1005.54 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Handling Class Prices § 1005.54 Equivalent price. See § 1000.54. Uniform Prices ...

  12. 7 CFR 1126.54 - Equivalent price.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 9 2010-01-01 2009-01-01 true Equivalent price. 1126.54 Section 1126.54 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Handling Class Prices § 1126.54 Equivalent price. See § 1000.54. Producer Price Differential ...

  13. 7 CFR 1001.54 - Equivalent price.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 9 2010-01-01 2009-01-01 true Equivalent price. 1001.54 Section 1001.54 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Handling Class Prices § 1001.54 Equivalent price. See § 1000.54. Producer Price Differential ...

  14. 7 CFR 1032.54 - Equivalent price.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 9 2010-01-01 2009-01-01 true Equivalent price. 1032.54 Section 1032.54 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Handling Class Prices § 1032.54 Equivalent price. See § 1000.54. Producer Price Differential ...

  15. 7 CFR 1033.54 - Equivalent price.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 9 2010-01-01 2009-01-01 true Equivalent price. 1033.54 Section 1033.54 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Handling Class Prices § 1033.54 Equivalent price. See § 1000.54. Producer Price Differential ...

  16. 7 CFR 1131.54 - Equivalent price.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 9 2010-01-01 2009-01-01 true Equivalent price. 1131.54 Section 1131.54 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Handling Class Prices § 1131.54 Equivalent price. See § 1000.54. Uniform Prices ...

  17. 7 CFR 1006.54 - Equivalent price.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 9 2010-01-01 2009-01-01 true Equivalent price. 1006.54 Section 1006.54 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Handling Class Prices § 1006.54 Equivalent price. See § 1000.54. Uniform Prices ...

  18. 7 CFR 1007.54 - Equivalent price.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 9 2010-01-01 2009-01-01 true Equivalent price. 1007.54 Section 1007.54 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Handling Class Prices § 1007.54 Equivalent price. See § 1000.54. Uniform Prices ...

  19. The Complexity of Identifying Large Equivalence Classes

    DEFF Research Database (Denmark)

    Skyum, Sven; Frandsen, Gudmund Skovbjerg; Miltersen, Peter Bro

    1999-01-01

    We prove that at least 3k−4/k(2k−3)(n/2) – O(k)equivalence tests and no more than 2/k (n/2) + O(n) equivalence tests are needed in the worst case to identify the equivalence classes with at least k members in set of n elements. The upper bound is an improvement by a factor 2 compared to known res...

  20. Radiobiological equivalent of low/high dose rate brachytherapy and evaluation of tumor and normal responses to the dose.

    Science.gov (United States)

    Manimaran, S

    2007-06-01

    The aim of this study was to compare the biological equivalent of low-dose-rate (LDR) and high-dose-rate (HDR) brachytherapy in terms of the more recent linear quadratic (LQ) model, which leads to theoretical estimation of biological equivalence. One of the key features of the LQ model is that it allows a more systematic radiobiological comparison between different types of treatment because the main parameters alpha/beta and micro are tissue-specific. Such comparisons also allow assessment of the likely change in the therapeutic ratio when switching between LDR and HDR treatments. The main application of LQ methodology, which focuses on by increasing the availability of remote afterloading units, has been to design fractionated HDR treatments that can replace existing LDR techniques. In this study, with LDR treatments (39 Gy in 48 h) equivalent to 11 fractions of HDR irradiation at the experimental level, there are increasing reports of reproducible animal models that may be used to investigate the biological basis of brachytherapy and to help confirm theoretical predictions. This is a timely development owing to the nonavailability of sufficient retrospective patient data analysis. It appears that HDR brachytherapy is likely to be a viable alternative to LDR only if it is delivered without a prohibitively large number of fractions (e.g., fewer than 11). With increased scientific understanding and technological capability, the prospect of a dose equivalent to HDR brachytherapy will allow greater utilization of the concepts discussed in this article.

  1. 7 CFR 1124.54 - Equivalent price.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 9 2010-01-01 2009-01-01 true Equivalent price. 1124.54 Section 1124.54 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Regulating Handling Class Prices § 1124.54 Equivalent price. See § 1000.54. Producer Price Differential ...

  2. EQUIVALENT MODELS IN COVARIANCE STRUCTURE-ANALYSIS

    NARCIS (Netherlands)

    LUIJBEN, TCW

    1991-01-01

    Defining equivalent models as those that reproduce the same set of covariance matrices, necessary and sufficient conditions are stated for the local equivalence of two expanded identified models M1 and M2 when fitting the more restricted model M0. Assuming several regularity conditions, the rank

  3. Quantum equivalence principle without mass superselection

    International Nuclear Information System (INIS)

    Hernandez-Coronado, H.; Okon, E.

    2013-01-01

    The standard argument for the validity of Einstein's equivalence principle in a non-relativistic quantum context involves the application of a mass superselection rule. The objective of this work is to show that, contrary to widespread opinion, the compatibility between the equivalence principle and quantum mechanics does not depend on the introduction of such a restriction. For this purpose, we develop a formalism based on the extended Galileo group, which allows for a consistent handling of superpositions of different masses, and show that, within such scheme, mass superpositions behave as they should in order to obey the equivalence principle. - Highlights: • We propose a formalism for consistently handling, within a non-relativistic quantum context, superpositions of states with different masses. • The formalism utilizes the extended Galileo group, in which mass is a generator. • The proposed formalism allows for the equivalence principle to be satisfied without the need of imposing a mass superselection rule

  4. Problems of Equivalence in Shona- English Bilingual Dictionaries

    African Journals Online (AJOL)

    rbr

    Page 1 ... translation equivalents in Shona-English dictionaries where lexicographers will be dealing with divergent languages and cultures, traditional practices of lexicography and the absence of reliable ... ideal in translation is to achieve structural and semantic equivalence. Absolute equivalence between any two ...

  5. 10 CFR 474.3 - Petroleum-equivalent fuel economy calculation.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Petroleum-equivalent fuel economy calculation. 474.3..., DEVELOPMENT, AND DEMONSTRATION PROGRAM; PETROLEUM-EQUIVALENT FUEL ECONOMY CALCULATION § 474.3 Petroleum-equivalent fuel economy calculation. (a) The petroleum-equivalent fuel economy for an electric vehicle is...

  6. Course design via Equivalency Theory supports equivalent student grades and satisfaction in online and face-to-face psychology classes

    Directory of Open Access Journals (Sweden)

    David eGarratt-Reed

    2016-05-01

    Full Text Available There has been a recent rapid growth in the number of psychology courses offered online through institutions of higher education. The American Psychological Association (APA has highlighted the importance of ensuring the effectiveness of online psychology courses. Despite this, there have been inconsistent findings regarding student grades, satisfaction, and retention in online psychology units. Equivalency Theory posits that online and classroom-based learners will attain equivalent learning outcomes when equivalent learning experiences are provided. We present a case study of an online introductory psychology unit designed to provide equivalent learning experiences to the pre-existing face-to-face version of the unit. Academic performance, student feedback, and retention data from 866 Australian undergraduate psychology students were examined to assess whether the online unit produced comparable outcomes to the ‘traditional’ unit delivered face-to-face. Student grades did not significantly differ between modes of delivery, except for a group-work based assessment where online students performed more poorly. Student satisfaction was generally high in both modes of the unit, with group-work the key source of dissatisfaction in the online unit. The results provide partial support for Equivalency Theory. The group-work based assessment did not provide an equivalent learning experience for students in the online unit highlighting the need for further research to determine effective methods of engaging students in online group activities. Consistent with previous research, retention rates were significantly lower in the online unit, indicating the need to develop effective strategies to increase online retention rates. While this study demonstrates successes in presenting online students with an equivalent learning experience, we recommend that future research investigates means of successfully facilitating collaborative group-work assessment

  7. Matching of equivalent field regions

    DEFF Research Database (Denmark)

    Appel-Hansen, Jørgen; Rengarajan, S.B.

    2005-01-01

    In aperture problems, integral equations for equivalent currents are often found by enforcing matching of equivalent fields. The enforcement is made in the aperture surface region adjoining the two volumes on each side of the aperture. In the case of an aperture in a planar perfectly conducting...... screen, having the same homogeneous medium on both sides and an impressed current on one aide, an alternative procedure is relevant. We make use of the fact that in the aperture the tangential component of the magnetic field due to the induced currents in the screen is zero. The use of such a procedure...... shows that equivalent currents can be found by a consideration of only one of the two volumes into which the aperture plane divides the space. Furthermore, from a consideration of an automatic matching at the aperture, additional information about tangential as well as normal field components...

  8. Behavioural equivalence for infinite systems - Partially decidable!

    DEFF Research Database (Denmark)

    Sunesen, Kim; Nielsen, Mogens

    1996-01-01

    languages with two generalizations based on traditional approaches capturing non-interleaving behaviour, pomsets representing global causal dependency, and locality representing spatial distribution of events. We first study equivalences on Basic Parallel Processes, BPP, a process calculus equivalent...... of processes between BPP and TCSP, not only are the two equivalences different, but one (locality) is decidable whereas the other (pomsets) is not. The decidability result for locality is proved by a reduction to the reachability problem for Petri nets....

  9. Relations of equivalence of conditioned radioactive waste

    International Nuclear Information System (INIS)

    Kumer, L.; Szeless, A.; Oszuszky, F.

    1982-01-01

    A compensation for the wastes remaining with the operator of a waste management center, to be given by the agent having caused the waste, may be assured by effecting a financial valuation (equivalence) of wastes. Technically and logically, this equivalence between wastes (or specifically between different waste categories) and financial valuation has been established as reasonable. In this paper, the possibility of establishing such equivalences are developed, and their suitability for waste management concepts is quantitatively expressed

  10. Equivalences of real submanifolds in complex space.

    OpenAIRE

    ZAITSEV, DMITRI

    2001-01-01

    PUBLISHED We show that for any real-analytic submanifold M in CN there is a proper real-analytic subvariety V contained in M such that for any p ? M \\ V , any real-analytic submanifold M? in CN, and any p? ? M?, the germs of the submanifolds M and M? at p and p? respectively are formally equivalent if and only if they are biholomorphically equivalent. More general results for k-equivalences are also stated and proved.

  11. A Cp-theory problem book functional equivalencies

    CERN Document Server

    Tkachuk, Vladimir V

    2016-01-01

    This fourth volume in Vladimir Tkachuk's series on Cp-theory gives reasonably complete coverage of the theory of functional equivalencies through 500 carefully selected problems and exercises. By systematically introducing each of the major topics of Cp-theory, the book is intended to bring a dedicated reader from basic topological principles to the frontiers of modern research. The book presents complete and up-to-date information on the preservation of topological properties by homeomorphisms of function spaces.  An exhaustive theory of t-equivalent, u-equivalent and l-equivalent spaces is developed from scratch.   The reader will also find introductions to the theory of uniform spaces, the theory of locally convex spaces, as well as  the theory of inverse systems and dimension theory. Moreover, the inclusion of Kolmogorov's solution of Hilbert's Problem 13 is included as it is needed for the presentation of the theory of l-equivalent spaces. This volume contains the most important classical re...

  12. Equivalence relations for the 9972-9975 SARP

    International Nuclear Information System (INIS)

    Niemer, K.A.; Frost, R.L.

    1994-10-01

    Equivalence relations required to determine mass limits for mixtures of nuclides for the Safety Analysis Report for Packaging (SARP) of the Savannah River Site 9972, 9973, 9974, and 9975 shipping casks were calculated. The systems analyzed included aqueous spheres, homogeneous metal spheres, and metal ball-and-shell configurations, all surrounded by an effectively infinite stainless steel or water reflector. Comparison of the equivalence calculations with the rule-of-fractions showed conservative agreement for aqueous solutions, both conservative and non-conservative agreement for the metal homogeneous sphere systems, and non-conservative agreement for the majority of metal ball-and-shell systems. Equivalence factors for the aqueous solutions and homogeneous metal spheres were calculated. The equivalence factors for the non-conservative metal homogeneous sphere systems were adjusted so that they were conservative. No equivalence factors were calculated for the ball-and-shell systems since the -SARP assumes that only homogeneous or uniformly distributed material will be shipped in the 9972-9975 shipping casks, and an unnecessarily conservative critical mass may result if the ball-and-shell configurations are included

  13. Equivalence of Szegedy's and coined quantum walks

    Science.gov (United States)

    Wong, Thomas G.

    2017-09-01

    Szegedy's quantum walk is a quantization of a classical random walk or Markov chain, where the walk occurs on the edges of the bipartite double cover of the original graph. To search, one can simply quantize a Markov chain with absorbing vertices. Recently, Santos proposed two alternative search algorithms that instead utilize the sign-flip oracle in Grover's algorithm rather than absorbing vertices. In this paper, we show that these two algorithms are exactly equivalent to two algorithms involving coined quantum walks, which are walks on the vertices of the original graph with an internal degree of freedom. The first scheme is equivalent to a coined quantum walk with one walk step per query of Grover's oracle, and the second is equivalent to a coined quantum walk with two walk steps per query of Grover's oracle. These equivalences lie outside the previously known equivalence of Szegedy's quantum walk with absorbing vertices and the coined quantum walk with the negative identity operator as the coin for marked vertices, whose precise relationships we also investigate.

  14. 7 CFR 1000.54 - Equivalent price.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 9 2010-01-01 2009-01-01 true Equivalent price. 1000.54 Section 1000.54 Agriculture... Prices § 1000.54 Equivalent price. If for any reason a price or pricing constituent required for computing the prices described in § 1000.50 is not available, the market administrator shall use a price or...

  15. A Bayesian equivalency test for two independent binomial proportions.

    Science.gov (United States)

    Kawasaki, Yohei; Shimokawa, Asanao; Yamada, Hiroshi; Miyaoka, Etsuo

    2016-01-01

    In clinical trials, it is often necessary to perform an equivalence study. The equivalence study requires actively denoting equivalence between two different drugs or treatments. Since it is not possible to assert equivalence that is not rejected by a superiority test, statistical methods known as equivalency tests have been suggested. These methods for equivalency tests are based on the frequency framework; however, there are few such methods in the Bayesian framework. Hence, this article proposes a new index that suggests the equivalency of binomial proportions, which is constructed based on the Bayesian framework. In this study, we provide two methods for calculating the index and compare the probabilities that have been calculated by these two calculation methods. Moreover, we apply this index to the results of actual clinical trials to demonstrate the utility of the index.

  16. The equivalence theorem

    International Nuclear Information System (INIS)

    Veltman, H.

    1990-01-01

    The equivalence theorem states that, at an energy E much larger than the vector-boson mass M, the leading order of the amplitude with longitudinally polarized vector bosons on mass shell is given by the amplitude in which these vector bosons are replaced by the corresponding Higgs ghosts. We prove the equivalence theorem and show its validity in every order in perturbation theory. We first derive the renormalized Ward identities by using the diagrammatic method. Only the Feynman-- 't Hooft gauge is discussed. The last step of the proof includes the power-counting method evaluated in the large-Higgs-boson-mass limit, needed to estimate the leading energy behavior of the amplitudes involved. We derive expressions for the amplitudes involving longitudinally polarized vector bosons for all orders in perturbation theory. The fermion mass has not been neglected and everything is evaluated in the region m f ∼M much-lt E much-lt m Higgs

  17. General Dynamic Equivalent Modeling of Microgrid Based on Physical Background

    Directory of Open Access Journals (Sweden)

    Changchun Cai

    2015-11-01

    Full Text Available Microgrid is a new power system concept consisting of small-scale distributed energy resources; storage devices and loads. It is necessary to employ a simplified model of microgrid in the simulation of a distribution network integrating large-scale microgrids. Based on the detailed model of the components, an equivalent model of microgrid is proposed in this paper. The equivalent model comprises two parts: namely, equivalent machine component and equivalent static component. Equivalent machine component describes the dynamics of synchronous generator, asynchronous wind turbine and induction motor, equivalent static component describes the dynamics of photovoltaic, storage and static load. The trajectory sensitivities of the equivalent model parameters with respect to the output variables are analyzed. The key parameters that play important roles in the dynamics of the output variables of the equivalent model are identified and included in further parameter estimation. Particle Swarm Optimization (PSO is improved for the parameter estimation of the equivalent model. Simulations are performed in different microgrid operation conditions to evaluate the effectiveness of the equivalent model of microgrid.

  18. 49 CFR 391.33 - Equivalent of road test.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Equivalent of road test. 391.33 Section 391.33... AND LONGER COMBINATION VEHICLE (LCV) DRIVER INSTRUCTORS Tests § 391.33 Equivalent of road test. (a) In place of, and as equivalent to, the road test required by § 391.31, a person who seeks to drive a...

  19. Foundations of gravitation theory: the principle of equivalence

    International Nuclear Information System (INIS)

    Haugan, M.P.

    1978-01-01

    A new framework is presented within which to discuss the principle of equivalence and its experimental tests. The framework incorporates a special structure imposed on the equivalence principle by the principle of energy conservation. This structure includes relations among the conceptual components of the equivalence principle as well as quantitative relations among the outcomes of its experimental tests. One of the most striking new results obtained through use of this framework is a connection between the breakdown of local Lorentz invariance and the breakdown of the principle that all bodies fall with the same acceleration in a gravitational field. An extensive discussion of experimental tests of the equivalence principle and their significance is also presented. Within the above framework, theory-independent analyses of a broad range of equivalence principle tests are possible. Gravitational redshift experiments. Doppler-shift experiments, the Turner-Hill and Hughes-Drever experiments, and a number of solar-system tests of gravitation theories are analyzed. Application of the techniques of theoretical nuclear physics to the quantitative interpretation of equivalence principle tests using laboratory materials of different composition yields a number of important results. It is found that current Eotvos experiments significantly demonstrate the compatibility of the weak interactions with the equivalence principle. It is also shown that the Hughes-Drever experiment is the most precise test of local Lorentz invariance yet performed. The work leads to a strong, tightly knit empirical basis for the principle of equivalence, the central pillar of the foundations of gravitation theory

  20. Mathematical simulation of biologically equivalent doses for LDR-HDR

    International Nuclear Information System (INIS)

    Slosarek, K.; Zajusz, A.

    1996-01-01

    Based on the LQ model examples of biologically equivalent doses LDR, HDR and external beams were calculated. The biologically equivalent doses for LDR were calculated by appending to the LQ model the corrector for the time of repair of radiation sublethal damages. For radiation continuously delivered at a low dose rate the influence of sublethal damage repair time changes on biologically equivalent doses were analysed. For fractionated treatment with high dose rate the biologically equivalent doses were calculated by adding to the LQ model the formula of accelerated repopulation. For total biologically equivalent dose calculation for combine LDR-HDR-Tele irradiation examples are presented with the use of different parameters of the time of repair of sublethal damages and accelerated repopulation. The calculations performed show, that the same biologically equivalent doses can be obtained for different parameters of cell kinetics changes during radiation treatment. It also shows, that during biologically equivalent dose calculations for different radiotherapy schedules, ignorance of cell kinetics parameters can lead to relevant errors

  1. The therapeutic alliance in internet interventions: A narrative review and suggestions for future research.

    Science.gov (United States)

    Berger, Thomas

    2017-09-01

    Research on Internet interventions has grown rapidly over the recent years and evidence is growing that Internet-based treatments often result in similar outcomes as conventional face-to-face psychotherapy. Yet there are still unanswered concerns such as whether a therapeutic alliance can be established over the Internet and whether the alliance is important in this new treatment format. A narrative review of studies formally assessing the therapeutic alliance in Internet interventions was conducted. It is the first review summarizing findings on the therapeutic alliance that (i) distinguishes between different forms of Internet interventions and (ii) does not restrict itself to specific Internet-based treatment formats such as guided self-help treatments, e-mail or videoconferencing therapies. Independent of communication modalities, diagnostic groups and amount of contact between clients and therapists, client-rated alliance scores were high, roughly equivalent to alliance ratings found in studies on face-to-face therapy. Mixed results were found regarding the therapist-rated alliance and alliance-outcome associations. The review points to the limitations of the available evidence and identifies unanswered questions. It is concluded that one of the major tasks for future research is to identify unique characteristics of the therapeutic alliance in the different treatment formats.

  2. Spaces of homotopy self-equivalences a survey

    CERN Document Server

    Rutter, John W

    1997-01-01

    This survey covers groups of homotopy self-equivalence classes of topological spaces, and the homotopy type of spaces of homotopy self-equivalences. For manifolds, the full group of equivalences and the mapping class group are compared, as are the corresponding spaces. Included are methods of calculation, numerous calculations, finite generation results, Whitehead torsion and other areas. Some 330 references are given. The book assumes familiarity with cell complexes, homology and homotopy. Graduate students and established researchers can use it for learning, for reference, and to determine the current state of knowledge.

  3. Equivalent nozzle in thermomechanical problems

    International Nuclear Information System (INIS)

    Cesari, F.

    1977-01-01

    When analyzing nuclear vessels, it is most important to study the behavior of the nozzle cylinder-cylinder intersection. For the elastic field, this analysis in three dimensions is quite easy using the method of finite elements. The same analysis in the non-linear field becomes difficult for designs in 3-D. It is therefore necessary to resolve a nozzle in two dimensions equivalent to a 3-D nozzle. The purpose of the present work is to find an equivalent nozzle both with a mechanical and thermal load. This has been achieved by the analysis in three dimensions of a nozzle and a nozzle cylinder-sphere intersection, of a different radius. The equivalent nozzle will be a nozzle with a sphere radius in a given ratio to the radius of a cylinder; thus, the maximum equivalent stress is the same in both 2-D and 3-D. The nozzle examined derived from the intersection of a cylindrical vessel of radius R=191.4 mm and thickness T=6.7 mm with a cylindrical nozzle of radius r=24.675 mm and thickness t=1.350 mm, for which the experimental results for an internal pressure load are known. The structure was subdivided into 96 finite, three-dimensional and isoparametric elements with 60 degrees of freedom and 661 total nodes. Both the analysis with a mechanical load as well as the analysis with a thermal load were carried out on this structure according to the Bersafe system. The thermal load consisted of a transient typical of an accident occurring in a sodium-cooled fast reactor, with a peak of the temperature (540 0 C) for the sodium inside the vessel with an insulating argon temperature constant at 525 0 C. The maximum value of the equivalent tension was found in the internal area at the union towards the vessel side. The analysis of the nozzle in 2-D consists in schematizing the structure as a cylinder-sphere intersection, where the sphere has a given relation to the

  4. Quantum mechanics and the equivalence principle

    International Nuclear Information System (INIS)

    Davies, P C W

    2004-01-01

    A quantum particle moving in a gravitational field may penetrate the classically forbidden region of the gravitational potential. This raises the question of whether the time of flight of a quantum particle in a gravitational field might deviate systematically from that of a classical particle due to tunnelling delay, representing a violation of the weak equivalence principle. I investigate this using a model quantum clock to measure the time of flight of a quantum particle in a uniform gravitational field, and show that a violation of the equivalence principle does not occur when the measurement is made far from the turning point of the classical trajectory. The results are then confirmed using the so-called dwell time definition of quantum tunnelling. I conclude with some remarks about the strong equivalence principle in quantum mechanics

  5. Equivalency of two-dimensional algebras

    International Nuclear Information System (INIS)

    Santos, Gildemar Carneiro dos; Pomponet Filho, Balbino Jose S.

    2011-01-01

    Full text: Let us consider a vector z = xi + yj over the field of real numbers, whose basis (i,j) satisfy a given algebra. Any property of this algebra will be reflected in any function of z, so we can state that the knowledge of the properties of an algebra leads to more general conclusions than the knowledge of the properties of a function. However structural properties of an algebra do not change when this algebra suffers a linear transformation, though the structural constants defining this algebra do change. We say that two algebras are equivalent to each other whenever they are related by a linear transformation. In this case, we have found that some relations between the structural constants are sufficient to recognize whether or not an algebra is equivalent to another. In spite that the basis transform linearly, the structural constants change like a third order tensor, but some combinations of these tensors result in a linear transformation, allowing to write the entries of the transformation matrix as function of the structural constants. Eventually, a systematic way to find the transformation matrix between these equivalent algebras is obtained. In this sense, we have performed the thorough classification of associative commutative two-dimensional algebras, and find that even non-division algebra may be helpful in solving non-linear dynamic systems. The Mandelbrot set was used to have a pictorial view of each algebra, since equivalent algebras result in the same pattern. Presently we have succeeded in classifying some non-associative two-dimensional algebras, a task more difficult than for associative one. (author)

  6. Attainment of radiation equivalency principle

    International Nuclear Information System (INIS)

    Shmelev, A.N.; Apseh, V.A.

    2004-01-01

    Problems connected with the prospects for long-term development of the nuclear energetics are discussed. Basic principles of the future large-scale nuclear energetics are listed, primary attention is the safety of radioactive waste management of nuclear energetics. The radiation equivalence principle means close of fuel cycle and management of nuclear materials transportation with low losses on spent fuel and waste processing. Two aspects are considered: radiation equivalence in global and local aspects. The necessity of looking for other strategies of fuel cycle management in full-scale nuclear energy on radioactive waste management is supported [ru

  7. Superstring field theory equivalence: Ramond sector

    International Nuclear Information System (INIS)

    Kroyter, Michael

    2009-01-01

    We prove that the finite gauge transformation of the Ramond sector of the modified cubic superstring field theory is ill-defined due to collisions of picture changing operators. Despite this problem we study to what extent could a bijective classical correspondence between this theory and the (presumably consistent) non-polynomial theory exist. We find that the classical equivalence between these two theories can almost be extended to the Ramond sector: We construct mappings between the string fields (NS and Ramond, including Chan-Paton factors and the various GSO sectors) of the two theories that send solutions to solutions in a way that respects the linearized gauge symmetries in both sides and keeps the action of the solutions invariant. The perturbative spectrum around equivalent solutions is also isomorphic. The problem with the cubic theory implies that the correspondence of the linearized gauge symmetries cannot be extended to a correspondence of the finite gauge symmetries. Hence, our equivalence is only formal, since it relates a consistent theory to an inconsistent one. Nonetheless, we believe that the fact that the equivalence formally works suggests that a consistent modification of the cubic theory exists. We construct a theory that can be considered as a first step towards a consistent RNS cubic theory.

  8. Equivalent drawbead performance in deep drawing simulations

    NARCIS (Netherlands)

    Meinders, Vincent T.; Geijselaers, Hubertus J.M.; Huetink, Han

    1999-01-01

    Drawbeads are applied in the deep drawing process to improve the control of the material flow during the forming operation. In simulations of the deep drawing process these drawbeads can be replaced by an equivalent drawbead model. In this paper the usage of an equivalent drawbead model in the

  9. S-equivalents lagrangians in generalized mechanics

    International Nuclear Information System (INIS)

    Negri, L.J.; Silva, Edna G. da.

    1985-01-01

    The problem of s-equivalent lagrangians is considered in the realm of generalized mechanics. Some results corresponding to the ordinary (non-generalized) mechanics are extended to the generalized case. A theorem for the reduction of the higher order lagrangian description to the usual order is found to be useful for the analysis of generalized mechanical systems and leads to a new class of equivalence between lagrangian functions. Some new perspectives are pointed out. (Author) [pt

  10. Dynamic equivalence relation on the fuzzy measure algebras

    Directory of Open Access Journals (Sweden)

    Roya Ghasemkhani

    2017-04-01

    Full Text Available The main goal of the present paper is to extend classical results from the measure theory and dynamical systems to the fuzzy subset setting. In this paper, the notion of  dynamic equivalence relation is introduced and then it is proved that this relation is an equivalence relation. Also, a new metric on the collection of all equivalence classes is introduced and it is proved that this metric is complete.

  11. Construction of a self-supporting tissue-equivalent dividing wall and operational characteristics of a coaxial double-cylindrical tissue-equivalent proportional counter

    International Nuclear Information System (INIS)

    Saion, E.B.; Watt, D.E.

    1994-01-01

    An additional feature incorporated in a coaxial double-cylindrical tissue-equivalent proportional counter, is the presence of a common tissue-equivalent dividing wall between the inner and outer counters of thickness equivalent to the corresponding maximum range of protons at the energy of interest. By appropriate use of an anti-coincidence arrangement with the outer counter, the inner counter could be used to discriminate microdosimetric spectra of neutrons at the desired low energy range from those of the faster neutrons. The construction of an A-150 self-supporting tissue-equivalent dividing wall and an anti-coincidence unit are described. Some operational characteristic tests have been performed to determine the operation of the new microdosimeter. (author)

  12. Geometry of the local equivalence of states

    Energy Technology Data Exchange (ETDEWEB)

    Sawicki, A; Kus, M, E-mail: assawi@cft.edu.pl, E-mail: marek.kus@cft.edu.pl [Center for Theoretical Physics, Polish Academy of Sciences, Al Lotnikow 32/46, 02-668 Warszawa (Poland)

    2011-12-09

    We present a description of locally equivalent states in terms of symplectic geometry. Using the moment map between local orbits in the space of states and coadjoint orbits of the local unitary group, we reduce the problem of local unitary equivalence to an easy part consisting of identifying the proper coadjoint orbit and a harder problem of the geometry of fibers of the moment map. We give a detailed analysis of the properties of orbits of 'equally entangled states'. In particular, we show connections between certain symplectic properties of orbits such as their isotropy and coisotropy with effective criteria of local unitary equivalence. (paper)

  13. Gyrokinetic equivalence

    International Nuclear Information System (INIS)

    Parra, Felix I; Catto, Peter J

    2009-01-01

    We compare two different derivations of the gyrokinetic equation: the Hamiltonian approach in Dubin D H E et al (1983 Phys. Fluids 26 3524) and the recursive methodology in Parra F I and Catto P J (2008 Plasma Phys. Control. Fusion 50 065014). We prove that both approaches yield the same result at least to second order in a Larmor radius over macroscopic length expansion. There are subtle differences in the definitions of some of the functions that need to be taken into account to prove the equivalence.

  14. Thévenin equivalent based static contingency assessment

    DEFF Research Database (Denmark)

    2015-01-01

    of the determined present state of the power system and determining a first representation of the network based on the determined Thevenin equivalents, determining a modified representation of the network, wherein the modified representation is a representation of the network having at least one contingency......, wherein at least one Thevenin equivalent of at least one voltage controlled node is modified due to the at least one contingency, the modified network representation being determined on the basis of the modified Thevenin equivalents, calculating voltage angles of the modified Thevenin equivalents......, and evaluating the voltage angles to determine whether the network having at least one contingency admit a steady state. Also a method of providing information on a real time static security assessment of a power system is disclosed....

  15. Teleparallel equivalent of Lovelock gravity

    Science.gov (United States)

    González, P. A.; Vásquez, Yerko

    2015-12-01

    There is a growing interest in modified gravity theories based on torsion, as these theories exhibit interesting cosmological implications. In this work inspired by the teleparallel formulation of general relativity, we present its extension to Lovelock gravity known as the most natural extension of general relativity in higher-dimensional space-times. First, we review the teleparallel equivalent of general relativity and Gauss-Bonnet gravity, and then we construct the teleparallel equivalent of Lovelock gravity. In order to achieve this goal, we use the vielbein and the connection without imposing the Weitzenböck connection. Then, we extract the teleparallel formulation of the theory by setting the curvature to null.

  16. Dark matter and the equivalence principle

    Science.gov (United States)

    Frieman, Joshua A.; Gradwohl, Ben-Ami

    1993-01-01

    A survey is presented of the current understanding of dark matter invoked by astrophysical theory and cosmology. Einstein's equivalence principle asserts that local measurements cannot distinguish a system at rest in a gravitational field from one that is in uniform acceleration in empty space. Recent test-methods for the equivalence principle are presently discussed as bases for testing of dark matter scenarios involving the long-range forces between either baryonic or nonbaryonic dark matter and ordinary matter.

  17. Equivalence of several Chern-Simons matter models

    International Nuclear Information System (INIS)

    Chen, W.; Itoi, C.

    1994-01-01

    Chern-Simons (CS) coupling characterizes not only statistics, but also spin and scaling dimension of matter fields. We demonstrate spin transmutation in relativistic CS matter theory, and moreover show equivalence of several models. We study the CS vector model in some detail, which provides a consistent check to the assertion of the equivalence

  18. Finding small equivalent decision trees is hard

    NARCIS (Netherlands)

    Zantema, H.; Bodlaender, H.L.

    2000-01-01

    Two decision trees are called decision equivalent if they represent the same function, i.e., they yield the same result for every possible input. We prove that given a decision tree and a number, to decide if there is a decision equivalent decision tree of size at most that number is NPcomplete. As

  19. Higher-order gravity and the classical equivalence principle

    Science.gov (United States)

    Accioly, Antonio; Herdy, Wallace

    2017-11-01

    As is well known, the deflection of any particle by a gravitational field within the context of Einstein’s general relativity — which is a geometrical theory — is, of course, nondispersive. Nevertheless, as we shall show in this paper, the mentioned result will change totally if the bending is analyzed — at the tree level — in the framework of higher-order gravity. Indeed, to first order, the deflection angle corresponding to the scattering of different quantum particles by the gravitational field mentioned above is not only spin dependent, it is also dispersive (energy-dependent). Consequently, it violates the classical equivalence principle (universality of free fall, or equality of inertial and gravitational masses) which is a nonlocal principle. However, contrary to popular belief, it is in agreement with the weak equivalence principle which is nothing but a statement about purely local effects. It is worthy of note that the weak equivalence principle encompasses the classical equivalence principle locally. We also show that the claim that there exists an incompatibility between quantum mechanics and the weak equivalence principle, is incorrect.

  20. Preparation of data relevant to ''Equivalent Uniform Burnup'' and Equivalent Initial Enrichment'' for burnup credit evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Nomura, Yasushi; Okuno, Hiroshi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Murazaki, Minoru [Tokyo Nuclear Service Inc., Tokyo (Japan)

    2001-11-01

    Based on the PWR spent fuel composition data measured at JAERI, two kinds of simplified methods such as ''Equivalent Uniform Burnup'' and ''Equivalent Initial Enrichment'' have been introduced. And relevant evaluation curves have been prepared for criticality safety evaluation of spent fuel storage pool and transport casks, taking burnup of spent fuel into consideration. These simplified methods can be used to obtain an effective neutron multiplication factor for a spent fuel storage/transportation system by using the ORIGEN2.1 burnup code and the KENO-Va criticality code without considering axial burnup profile in spent fuel and other various factors introducing calculated errors. ''Equivalent Uniform Burnup'' is set up for its criticality analysis to be reactivity equivalent with the detailed analysis, in which the experimentally obtained isotopic composition together with a typical axial burnup profile and various factors such as irradiation history are considered on the conservative side. On the other hand, Equivalent Initial Enrichment'' is set up for its criticality analysis to be reactivity equivalent with the detailed analysis such as above when it is used in the so called fresh fuel assumption. (author)

  1. Functional electrical stimulation and ankle foot orthoses provide equivalent therapeutic effects on foot drop: A meta-analysis providing direction for future research

    Directory of Open Access Journals (Sweden)

    Sarah Prenton

    2017-10-01

    Full Text Available Objective: To compare the randomized controlled trial evidence for therapeutic effects on walking of functional electrical stimulation and ankle foot orthoses for foot drop caused by central nervous system conditions. Data sources: MEDLINE, CINAHL, Cochrane Central Register of Controlled Trials, REHABDATA, PEDro, NIHR Centre for Reviews and Dissemination, Scopus and clinicaltrials.gov. Study selection: One reviewer screened titles/abstracts. Two independent reviewers then screened the full articles. Data extraction: One reviewer extracted data, another screened for accuracy. Risk of bias was assessed by 2 independent reviewers using the Cochrane Risk of Bias Tool. Data synthesis: Eight papers were eligible; 7 involving participants with stroke and 1 involving participants with cerebral palsy. Two papes reporting different measures from the same trial were grouped, resulting in 7 synthesized randomized controlled trials (n= 464. Meta-analysis of walking speed at final assessment (p = 0.46, for stroke participants (p = 0.54 and after 4–6 weeks’ use (p = 0.49 showed equal improvement for both devices. Conclusion: Functional electrical stimulation and ankle foot orthoses have an equally positive therapeutic effect on walking speed in non-progressive central nervous system diagnoses. The current randomized controlled trial evidence base does not show whether this improvement translates into the user’s own environment or reveal the mechanisms that achieve that change. Future studies should focus on measuring activity, muscle activity and gait kinematics. They should also report specific device details, capture sustained therapeutic effects and involve a variety of central nervous system diagnoses.

  2. Analysis of equivalent antenna based on FDTD method

    Directory of Open Access Journals (Sweden)

    Yun-xing Yang

    2014-09-01

    Full Text Available An equivalent microstrip antenna used in radio proximity fuse is presented. The design of this antenna is based on multilayer multi-permittivity dielectric substrate which is analyzed by finite difference time domain (FDTD method. Equivalent iterative formula is modified in the condition of cylindrical coordinate system. The mixed substrate which contains two kinds of media (one of them is airtakes the place of original single substrate. The results of equivalent antenna simulation show that the resonant frequency of equivalent antenna is similar to that of the original antenna. The validity of analysis can be validated by means of antenna resonant frequency formula. Two antennas have same radiation pattern and similar gain. This method can be used to reduce the weight of antenna, which is significant to the design of missile-borne antenna.

  3. What is Metaphysical Equivalence? | Miller | Philosophical Papers

    African Journals Online (AJOL)

    Theories are metaphysically equivalent just if there is no fact of the matter that could render one theory true and the other false. In this paper I argue that if we are judiciously to resolve disputes about whether theories are equivalent or not, we need to develop testable criteria that will give us epistemic access to the obtaining ...

  4. The Source Equivalence Acceleration Method

    International Nuclear Information System (INIS)

    Everson, Matthew S.; Forget, Benoit

    2015-01-01

    Highlights: • We present a new acceleration method, the Source Equivalence Acceleration Method. • SEAM forms an equivalent coarse group problem for any spatial method. • Equivalence is also formed across different spatial methods and angular quadratures. • Testing is conducted using OpenMOC and performance is compared with CMFD. • Results show that SEAM is preferable for very expensive transport calculations. - Abstract: Fine-group whole-core reactor analysis remains one of the long sought goals of the reactor physics community. Such a detailed analysis is typically too computationally expensive to be realized on anything except the largest of supercomputers. Recondensation using the Discrete Generalized Multigroup (DGM) method, though, offers a relatively cheap alternative to solving the fine group transport problem. DGM, however, suffered from inconsistencies when applied to high-order spatial methods. While an exact spatial recondensation method was developed and provided full spatial consistency with the fine group problem, this approach substantially increased memory requirements for realistic problems. The method described in this paper, called the Source Equivalence Acceleration Method (SEAM), forms a coarse-group problem which preserves the fine-group problem even when using higher order spatial methods. SEAM allows recondensation to converge to the fine-group solution with minimal memory requirements and little additional overhead. This method also provides for consistency when using different spatial methods and angular quadratures between the coarse group and fine group problems. SEAM was implemented in OpenMOC, a 2D MOC code developed at MIT, and its performance tested against Coarse Mesh Finite Difference (CMFD) acceleration on the C5G7 benchmark problem and on a 361 group version of the problem. For extremely expensive transport calculations, SEAM was able to outperform CMFD, resulting in speed-ups of 20–45 relative to the normal power

  5. Using frequency equivalency in stability calculations

    Energy Technology Data Exchange (ETDEWEB)

    Gruzdev, I.A.; Temirbulatov, R.A.; Tereshko, L.A.

    1981-01-01

    A methodology for calculating oscillatory instability that involves using frequency equivalency is employed in carrying out the following proceedures: dividing an electric power system into subgroups; determining the adjustments to the automatic excitation control in each subsystem; simplifying the mathematical definition of the separate subsystems by using frequency equivalency; gradually re-tuning the automatic excitation control in the separate subsystems to account for neighboring subsystems by using their equivalent frequency characteristics. The methodology is to be used with a computer program to determine the gain in the stabilization channels of the automatic excitation control unit in which static stability of the entire aggregate of normal and post-breakdown conditions acceptable damping of transient processes are provided. The possibility of reducing the equation series to apply to chosen regions of the existing range of frequencies is demonstrated. The use of the methodology is illustrated in a sample study on stability in a Siberian unified power system.

  6. Water equivalence of polymer gel dosimeters

    International Nuclear Information System (INIS)

    Sellakumar, P.; James Jebaseelan Samuel, E.; Supe, Sanjay S.

    2007-01-01

    To evaluate the water equivalence and radiation transport properties of polymer gel dosimeters over the wide range of photon and electron energies 14 different types of polymer gels were considered. Their water equivalence was evaluated in terms of effective atomic number (Z eff ), electron density (ρ e ), photon mass attenuation coefficient (μ/ρ), photon mass energy absorption coefficient (μ en /ρ) and total stopping power (S/ρ) tot of electrons using the XCOM and the ESTAR database. The study showed that the effective atomic number of polymer gels were very close ( en /ρ for all polymer gels were in close agreement ( tot of electrons in polymer gel dosimeters were within 1% agreement with that of water. From the study we conclude that at lower energy (<80keV) the polymer gel dosimeters cannot be considered water equivalent and study has to be carried out before using the polymer gel for clinical application

  7. Equivalence principle violations and couplings of a light dilaton

    International Nuclear Information System (INIS)

    Damour, Thibault; Donoghue, John F.

    2010-01-01

    We consider possible violations of the equivalence principle through the exchange of a light 'dilaton-like' scalar field. Using recent work on the quark-mass dependence of nuclear binding, we find that the dilaton-quark-mass coupling induces significant equivalence-principle-violating effects varying like the inverse cubic root of the atomic number - A -1/3 . We provide a general parametrization of the scalar couplings, but argue that two parameters are likely to dominate the equivalence-principle phenomenology. We indicate the implications of this framework for comparing the sensitivities of current and planned experimental tests of the equivalence principle.

  8. A bicategorical approach to Morita equivalence for von Neumann algebras

    International Nuclear Information System (INIS)

    Brouwer, R. M.

    2003-01-01

    We relate Morita equivalence for von Neumann algebras to the ''Connes fusion'' tensor product between correspondences. In the purely algebraic setting, it is well known that rings are Morita equivalent if they are equivalent objects in a bicategory whose 1-cells are bimodules. We present a similar result for von Neumann algebras. We show that von Neumann algebras form a bicategory, having Connes's correspondences as 1-morphisms, and (bounded) intertwiners as 2-morphisms. Further, we prove that two von Neumann algebras are Morita equivalent iff they are equivalent objects in the bicategory. The proofs make extensive use of the Tomita-Takesaki modular theory

  9. An equivalent fluid/equivalent medium approach for the numerical simulation of coastal landslides propagation: theory and case studies

    OpenAIRE

    P. Mazzanti; F. Bozzano

    2009-01-01

    Coastal and subaqueous landslides can be very dangerous phenomena since they are characterised by the additional risk of induced tsunamis, unlike their completely-subaerial counterparts. Numerical modelling of landslides propagation is a key step in forecasting the consequences of landslides. In this paper, a novel approach named Equivalent Fluid/Equivalent Medium (EFEM) has been developed. It adapts common numerical models and software that were originally designed for subaerial landslides i...

  10. The equivalence principle in classical mechanics and quantum mechanics

    OpenAIRE

    Mannheim, Philip D.

    1998-01-01

    We discuss our understanding of the equivalence principle in both classical mechanics and quantum mechanics. We show that not only does the equivalence principle hold for the trajectories of quantum particles in a background gravitational field, but also that it is only because of this that the equivalence principle is even to be expected to hold for classical particles at all.

  11. A Neurocomputational Approach to Trained and Transitive Relations in Equivalence Classes

    Directory of Open Access Journals (Sweden)

    Ángel E. Tovar

    2017-10-01

    Full Text Available A stimulus class can be composed of perceptually different but functionally equivalent stimuli. The relations between the stimuli that are grouped in a class can be learned or derived from other stimulus relations. If stimulus A is equivalent to B, and B is equivalent to C, then the equivalence between A and C can be derived without explicit training. In this work we propose, with a neurocomputational model, a basic learning mechanism for the formation of equivalence. We also describe how the relatedness between the members of an equivalence class is developed for both trained and derived stimulus relations. Three classic studies on stimulus equivalence are simulated covering typical and atypical populations as well as nodal distance effects. This model shows a mechanism by which certain stimulus associations are selectively strengthened even when they are not co-presented in the environment. This model links the field of equivalence classes to accounts of Hebbian learning and categorization, and points to the pertinence of modeling stimulus equivalence to explore the effect of variations in training protocols.

  12. On the calibration of photon dosemeters in the equivalent dose units

    International Nuclear Information System (INIS)

    Bregadze, Yu.I.; Isaev, B.M.; Maslyaev, P.F.

    1980-01-01

    General aspects of transition from exposure dose of photo radiation to equivalent one are considered. By determination the equivalent dose is a function of point location in an irradiated object, that is why it is necessary to know equivalent dose distribution in the human body for uniform description of the risk degree. The international electrotechnical comission recommends to measure equivalent doses at 7 and 800 mg/cm 2 depths in a tissue-equivalent ball with 30 cm diameter, calling them skin equivalent dose and depth equivalent dose, respectively, and to compare them with the permissible 500 mZ and 50 mZ a year, respectively. Practical transition to using equivalent dose for evaluation of radiation danger of being in photon radiation field of low energy should include measures on regraduating already produced dose meters, graduating the dose meters under production and developing the system of their metrologic supply [ru

  13. The lexicographical handling of grammatical equivalence: the case ...

    African Journals Online (AJOL)

    Lexicographers compiling translating dictionaries are not exclusively concerned with semantic equivalence when selecting translating equivalents for lemmata, but often include also grammatical information in illustrative examples when the lexical item to be translated does not have an exact grammatical counterpart in the ...

  14. The cross-cultural equivalence of participation instruments: a systematic review.

    Science.gov (United States)

    Stevelink, S A M; van Brakel, W H

    2013-07-01

    Concepts such as health-related quality of life, disability and participation may differ across cultures. Consequently, when assessing such a concept using a measure developed elsewhere, it is important to test its cultural equivalence. Previous research suggested a lack of cultural equivalence testing in several areas of measurement. This paper reviews the process of cross-cultural equivalence testing of instruments to measure participation in society. An existing cultural equivalence framework was adapted and used to assess participation instruments on five categories of equivalence: conceptual, item, semantic, measurement and operational equivalence. For each category, several aspects were rated, resulting in an overall category rating of 'minimal/none', 'partial' or 'extensive'. The best possible overall study rating was five 'extensive' ratings. Articles were included if the instruments focussed explicitly on measuring 'participation' and were theoretically grounded in the ICIDH(-2) or ICF. Cross-validation articles were only included if it concerned an adaptation of an instrument developed in a high or middle-income country to a low-income country or vice versa. Eight cross-cultural validation studies were included in which five participation instruments were tested (Impact on Participation and Autonomy, London Handicap Scale, Perceived Impact and Problem Profile, Craig Handicap Assessment Reporting Technique, Participation Scale). Of these eight studies, only three received at least two 'extensive' ratings for the different categories of equivalence. The majority of the cultural equivalence ratings given were 'partial' and 'minimal/none'. The majority of the 'none/minimal' ratings were given for item and measurement equivalence. The cross-cultural equivalence testing of the participation instruments included leaves much to be desired. A detailed checklist is proposed for designing a cross-validation study. Once a study has been conducted, the checklist can

  15. Radiation doses by therapeutical practices with iodine 131

    International Nuclear Information System (INIS)

    Di Trano, J.L.; Rojo, A.M.; Gomez Parada, I.M.; Grassi, E.; Gatica, N.; Kunst, J.J.; Gonzalez, M.

    1998-01-01

    The aim of this document is to estimate the doses to workers and public due to therapeutical practices with iodine 131. Environmental and personal doses by external irradiation were determined using thermoluminescent dosimeters (TLD). The environmental dosimetry resulted in an equivalent dose H * (10) of approximately 0,1 mSv. The calculated personal equivalent dose Hp (10) was of the order of 0,1 mSv. The exposition rate was measured, being the values obtained in the range of 0,20 and 0,35 mSv/h. (1m from the abdominal wall). Concentrations of iodine 131 were determinate in the air of the room, during the first day in the hospital. Values obtained were between 0,04 Bq/l and 0,20 Bq/l. Surface samples were taken in the service, obtaining levels of contamination in the range of 0,001 and 0,4 Bq/cm 2 . The surface samples obtained in the hospital room were about 0,15 Bq/cm 2 . Urine samples were collected resulting in an eliminated activity of iodine 131, during the first 24 hours, of about 60 % of the administered activity. Samples of sweat of different cutaneous regions were obtained, the maximum values of the activity measured reached 200 Bq/cm 2 . According to the obtained results it is important to elaborate guides to be given to patients as an instrument to reduce the external exposure and to avoid internal contamination. (author)

  16. Simulation-Based Prediction of Equivalent Continuous Noises during Construction Processes.

    Science.gov (United States)

    Zhang, Hong; Pei, Yun

    2016-08-12

    Quantitative prediction of construction noise is crucial to evaluate construction plans to help make decisions to address noise levels. Considering limitations of existing methods for measuring or predicting the construction noise and particularly the equivalent continuous noise level over a period of time, this paper presents a discrete-event simulation method for predicting the construction noise in terms of equivalent continuous level. The noise-calculating models regarding synchronization, propagation and equivalent continuous level are presented. The simulation framework for modeling the noise-affected factors and calculating the equivalent continuous noise by incorporating the noise-calculating models into simulation strategy is proposed. An application study is presented to demonstrate and justify the proposed simulation method in predicting the equivalent continuous noise during construction. The study contributes to provision of a simulation methodology to quantitatively predict the equivalent continuous noise of construction by considering the relevant uncertainties, dynamics and interactions.

  17. Verification of an effective dose equivalent model for neutrons

    International Nuclear Information System (INIS)

    Tanner, J.E.; Piper, R.K.; Leonowich, J.A.; Faust, L.G.

    1992-01-01

    Since the effective dose equivalent, based on the weighted sum of organ dose equivalents, is not a directly measurable quantity, it must be estimated with the assistance of computer modelling techniques and a knowledge of the incident radiation field. Although extreme accuracy is not necessary for radiation protection purposes, a few well chosen measurements are required to confirm the theoretical models. Neutron doses and dose equivalents were measured in a RANDO phantom at specific locations using thermoluminescence dosemeters, etched track dosemeters, and a 1.27 cm (1/2 in) tissue-equivalent proportional counter. The phantom was exposed to a bare and a D 2 O-moderated 252 Cf neutron source at the Pacific Northwest Laboratory's Low Scatter Facility. The Monte Carlo code MCNP with the MIRD-V mathematical phantom was used to model the human body and to calculate the organ doses and dose equivalents. The experimental methods are described and the results of the measurements are compared with the calculations. (author)

  18. The Application of Equivalence Theory to Advertising Translation

    Institute of Scientific and Technical Information of China (English)

    张颖

    2017-01-01

    Through analyzing equivalence theory, the author tries to find a solution to the problems arising in the process of ad?vertising translation. These problems include cultural diversity, language diversity and special requirement of advertisement. The author declares that Nida''s functional equivalence is one of the most appropriate theories to deal with these problems. In this pa?per, the author introduces the principles of advertising translation and culture divergences in advertising translation, and then gives some advertising translation practices to explain and analyze how to create good advertising translation by using functional equivalence. At last, the author introduces some strategies in advertising translation.

  19. The principle of equivalence

    International Nuclear Information System (INIS)

    Unnikrishnan, C.S.

    1994-01-01

    Principle of equivalence was the fundamental guiding principle in the formulation of the general theory of relativity. What are its key elements? What are the empirical observations which establish it? What is its relevance to some new experiments? These questions are discussed in this article. (author). 11 refs., 5 figs

  20. Equivalent Colorings with "Maple"

    Science.gov (United States)

    Cecil, David R.; Wang, Rongdong

    2005-01-01

    Many counting problems can be modeled as "colorings" and solved by considering symmetries and Polya's cycle index polynomial. This paper presents a "Maple 7" program link http://users.tamuk.edu/kfdrc00/ that, given Polya's cycle index polynomial, determines all possible associated colorings and their partitioning into equivalence classes. These…

  1. Lipschitz equivalence of self-similar sets with touching structures

    International Nuclear Information System (INIS)

    Ruan, Huo-Jun; Wang, Yang; Xi, Li-Feng

    2014-01-01

    Lipschitz equivalence of self-similar sets is an important area in the study of fractal geometry. It is known that two dust-like self-similar sets with the same contraction ratios are always Lipschitz equivalent. However, when self-similar sets have touching structures the problem of Lipschitz equivalence becomes much more challenging and intriguing at the same time. So far, all the known results only cover self-similar sets in R with no more than three branches. In this study we establish results for the Lipschitz equivalence of self-similar sets with touching structures in R with arbitrarily many branches. Key to our study is the introduction of a geometric condition for self-similar sets called substitutable. (paper)

  2. Estimating water equivalent snow depth from related meteorological variables

    International Nuclear Information System (INIS)

    Steyaert, L.T.; LeDuc, S.K.; Strommen, N.D.; Nicodemus, M.L.; Guttman, N.B.

    1980-05-01

    Engineering design must take into consideration natural loads and stresses caused by meteorological elements, such as, wind, snow, precipitation and temperature. The purpose of this study was to determine a relationship of water equivalent snow depth measurements to meteorological variables. Several predictor models were evaluated for use in estimating water equivalent values. These models include linear regression, principal component regression, and non-linear regression models. Linear, non-linear and Scandanavian models are used to generate annual water equivalent estimates for approximately 1100 cooperative data stations where predictor variables are available, but which have no water equivalent measurements. These estimates are used to develop probability estimates of snow load for each station. Map analyses for 3 probability levels are presented

  3. A bicategorical approach to Morita equivalence for Von Neumann algebras

    NARCIS (Netherlands)

    R.M. Brouwer (Rachel)

    2003-01-01

    textabstractWe relate Morita equivalence for von Neumann algebras to the ``Connes fusion'' tensor product between correspondences. In the purely algebraic setting, it is well known that rings are Morita equivalent if and only if they are equivalent objects in a bicategory whose 1-cells are

  4. The effects of therapeutic climbing in patients with chronic low back pain: a randomized controlled study.

    Science.gov (United States)

    Engbert, Kai; Weber, Michaela

    2011-05-15

    a standard exercise regime. In two subscales of the SF-36, the benefits of therapeutic climbing exceeded those of standard exercise therapy, primarily in perceived health and physical functioning of the patients. This finding demonstrates that therapeutic climbing is equivalent and partly superior to standard exercise therapy for patients with chronic low back pain.

  5. Fiber-coupled Luminescence Dosimetry in Therapeutic and Diagnostic Radiology

    DEFF Research Database (Denmark)

    Andersen, Claus Erik

    2011-01-01

    . Some crystalline phosphors, such as carbon-doped aluminium oxide (Al2O3:C) have the ability to store charge produced in the crystal during irradiation. The stored charge may later be released by fiber-guided laser light under emission of so-called optically stimulated luminescence (OSL). The OSL signal......Fiber-coupled luminescence dosimetry is an emerging technology with several potentially attractive features of relevance for uses in therapeutic and diagnostic radiology: direct water equivalence (i.e. no significant perturbation of the radiation field in a water phantom or a patient), sub......-mm detector size, high dynamic range (below a mGy to several Gy), microsecond time resolution, and absence of electrical wires or other electronics in the dosimeter probe head. Fiber-coupled luminescence dosimetry systems typically consist of one or more small samples of phosphor, e.g. a mg of plastic...

  6. Bisimulation Meet PCTL Equivalences for Probabilistic Automata (Journal Version)

    DEFF Research Database (Denmark)

    Song, Lei; Zhang, Lijun; Godskesen, Jens Christian

    2013-01-01

    Probabilistic automata (PA) have been successfully applied in the formal verification of concurrent and stochastic systems. Efficient model checking algorithms have been studied, where the most often used logics for expressing properties are based on PCTL and its extension PCTL*. Various behavioral...... equivalences are proposed for PAs, as a powerful tool for abstraction and compositional minimization for PAs. Unfortunately, the behavioral equivalences are well-known to be strictly stronger than the logical equivalences induced by PCTL or PCTL*. This paper introduces novel notions of strong bisimulation...... relations, which characterizes PCTL and PCTL* exactly. We also extend weak bisimulations characterizing PCTL and PCTL* without next operator, respectively. Thus, our paper bridges the gap between logical and behavioral equivalences in this setting....

  7. Modelling of dynamic equivalents in electric power grids

    International Nuclear Information System (INIS)

    Craciun, Diana Iuliana

    2010-01-01

    In a first part, this research thesis proposes a description of the context and new constraints of electric grids: architecture, decentralized production with the impact of distributed energy resource systems, dynamic simulation, and interest of equivalent models. Then, the author discusses the modelling of the different components of electric grids: synchronous and asynchronous machines, distributed energy resource with power electronic interface, loading models. She addresses the techniques of reduction of electric grid models: conventional reduction methods, dynamic equivalence methods using non linear approaches or evolutionary algorithm-based methods of assessment of parameters. This last approach is then developed and implemented, and a new method of computation of dynamic equivalents is described

  8. The experimental method for neutron dose-equivalent detection

    International Nuclear Information System (INIS)

    Ji Changsong

    1992-01-01

    A new method, for getting neutron dose-equivalent Cd rode absorption method is described. The method adopts Cd-rode-swarm buck absorption, which greatly improved the neutron sensitivity and simplified the adjustment method. By this method, the author has developed BH3105 model neutron dose equivalent meter, the sensitivity of this instrument reach 10 cps/μSvh -1 . γ-ray depression rate reaches 4000:1, the measurement range is 0.1 μSv/h-10 6 μSv/h. The energy response is good (from thermal neutron-14 MeV neutron), this instrument can be used to measure the dose equivalent of the neutron areas

  9. Equivalence of quantum states under local unitary transformations

    International Nuclear Information System (INIS)

    Fei Shaoming; Jing Naihuan

    2005-01-01

    In terms of the analysis of fixed point subgroup and tensor decomposability of certain matrices, we study the equivalence of quantum bipartite mixed states under local unitary transformations. For non-degenerate case an operational criterion for the equivalence of two such mixed bipartite states under local unitary transformations is presented

  10. Verification of an effective dose equivalent model for neutrons

    International Nuclear Information System (INIS)

    Tanner, J.E.; Piper, R.K.; Leonowich, J.A.; Faust, L.G.

    1991-10-01

    Since the effective dose equivalent, based on the weighted sum of organ dose equivalents, is not a directly measurable quantity, it must be estimated with the assistance of computer modeling techniques and a knowledge of the radiation field. Although extreme accuracy is not necessary for radiation protection purposes, a few well-chosen measurements are required to confirm the theoretical models. Neutron measurements were performed in a RANDO phantom using thermoluminescent dosemeters, track etch dosemeters, and a 1/2-in. (1.27-cm) tissue equivalent proportional counter in order to estimate neutron doses and dose equivalents within the phantom at specific locations. The phantom was exposed to bare and D 2 O-moderated 252 Cf neutrons at the Pacific Northwest Laboratory's Low Scatter Facility. The Monte Carlo code MCNP with the MIRD-V mathematical phantom was used to model the human body and calculate organ doses and dose equivalents. The experimental methods are described and the results of the measurements are compared to the calculations. 8 refs., 3 figs., 3 tabs

  11. Inertia and Double Bending of Light from Equivalence

    Science.gov (United States)

    Shuler, Robert L., Jr.

    2010-01-01

    Careful examination of light paths in an accelerated reference frame, with use of Special Relativity, can account fully for the observed bending of light in a gravitational field, not just half of it as reported in 1911. This analysis also leads to a Machian formulation of inertia similar to the one proposed by Einstein in 1912 and later derived from gravitational field equations in Minkowsky Space by Sciama in 1953. There is a clear inference from equivalence that there is some type of inertial mass increase in a gravitational field. It is the purpose of the current paper to suggest that equivalence provides a more complete picture of gravitational effects than previously thought, correctly predicting full light bending, and that since the theory of inertia is derivable from equivalence, any theory based on equivalence must take account of it. Einstein himself clearly was not satisfied with the status of inertia in GRT, as our quotes have shown. Many have tried to account for inertia and met with less than success, for example Davidson s integration of Sciama s inertia into GRT but only for a steady state cosmology [10], and the Machian gravity theory of Brans and Dicke [11]. Yet Mach s idea hasn t gone away, and now it seems that it cannot go away without also disposing of equivalence.

  12. The transfer of Cfunc contextual control through equivalence relations.

    Science.gov (United States)

    Perez, William F; Fidalgo, Adriana P; Kovac, Roberta; Nico, Yara C

    2015-05-01

    Derived relational responding is affected by contextual stimuli (Cfunc) that select specific stimulus functions. The present study investigated the transfer of Cfunc contextual control through equivalence relations by evaluating both (a) the maintenance of Cfunc contextual control after the expansion of a relational network, and (b) the establishment of novel contextual stimuli by the transfer of Cfunc contextual control through equivalence relations. Initially, equivalence relations were established and contingencies were arranged so that colors functioned as Cfunc stimuli controlling participants' key-pressing responses in the presence of any stimulus from a three-member equivalence network. To investigate the first research question, the three-member equivalence relations were expanded to five members and the novel members were presented with the Cfunc stimuli in the key-pressing task. To address the second goal of this study, the colors (Cfunc) were established as equivalent to certain line patterns. The transfer of contextual cue function (Cfunc) was tested replacing the colored backgrounds with line patterns in the key-pressing task. Results suggest that the Cfunc contextual control was transferred to novel stimuli that were added to the relational network. In addition, the line patterns indirectly acquired the contextual cue function (Cfunc) initially established for the colored backgrounds. The conceptual and applied implications of Cfunc contextual control are discussed. © Society for the Experimental Analysis of Behavior.

  13. 10 CFR 20.1208 - Dose equivalent to an embryo/fetus.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Dose equivalent to an embryo/fetus. 20.1208 Section 20... Limits § 20.1208 Dose equivalent to an embryo/fetus. (a) The licensee shall ensure that the dose equivalent to the embryo/fetus during the entire pregnancy, due to the occupational exposure of a declared...

  14. Multi-channel phase-equivalent transformation and supersymmetry

    OpenAIRE

    Shirokov, A. M.; Sidorenko, V. N.

    2000-01-01

    Phase-equivalent transformation of local interaction is generalized to the multi-channel case. Generally, the transformation does not change the number of the bound states in the system and their energies. However, with a special choice of the parameters, the transformation removes one of the bound states and is equivalent to the multi-channel supersymmetry transformation recently suggested by Sparenberg and Baye. Using the transformation, it is also possible to add a bound state to the discr...

  15. Preparation of A-150 tissue-equivalent plastic films

    International Nuclear Information System (INIS)

    Saion, E.B.; Shaari, A.H.; Watt, D.E.

    1992-01-01

    A-150 tissue-equivalent (TE) plastic is widely used as a wall material for tissue-equivalent proportional counters (TEPCS) used in experimental microdosimetry. The objective of this note is to give a technical account of how A-150 TE plastic film can be fabricated in the laboratory from commercially available A-150 TE plastic. (author)

  16. An analytical model of leakage neutron equivalent dose for passively-scattered proton radiotherapy and validation with measurements.

    Science.gov (United States)

    Schneider, Christopher; Newhauser, Wayne; Farah, Jad

    2015-05-18

    Exposure to stray neutrons increases the risk of second cancer development after proton therapy. Previously reported analytical models of this exposure were difficult to configure and had not been investigated below 100 MeV proton energy. The purposes of this study were to test an analytical model of neutron equivalent dose per therapeutic absorbed dose  at 75 MeV and to improve the model by reducing the number of configuration parameters and making it continuous in proton energy from 100 to 250 MeV. To develop the analytical model, we used previously published H/D values in water from Monte Carlo simulations of a general-purpose beamline for proton energies from 100 to 250 MeV. We also configured and tested the model on in-air neutron equivalent doses measured for a 75 MeV ocular beamline. Predicted H/D values from the analytical model and Monte Carlo agreed well from 100 to 250 MeV (10% average difference). Predicted H/D values from the analytical model also agreed well with measurements at 75 MeV (15% average difference). The results indicate that analytical models can give fast, reliable calculations of neutron exposure after proton therapy. This ability is absent in treatment planning systems but vital to second cancer risk estimation.

  17. State-Dependent Implication and Equivalence in Quantum Logic

    Directory of Open Access Journals (Sweden)

    Fedor Herbut

    2012-01-01

    Full Text Available Ideal occurrence of an event (projector leads to the known change of a state (density operator into (the Lüders state. It is shown that two events and give the same Lüders state if and only if the equivalence relation is valid. This relation determines equivalence classes. The set of them and each class, are studied in detail. It is proved that the range projector of the Lüders state can be evaluated as , where denotes the greatest lower bound, and is the null projector of . State-dependent implication extends absolute implication (which, in turn, determines the entire structure of quantum logic. and are investigated in a closely related way to mutual benefit. Inherent in the preorder is the state-dependent equivalence , defining equivalence classes in a given Boolean subalgebra. The quotient set, in which the classes are the elements, has itself a partially ordered structure, and so has each class. In a complete Boolean subalgebra, both structures are complete lattices. Physical meanings are discussed.

  18. Mirror-Image Equivalence and Interhemispheric Mirror-Image Reversal.

    Science.gov (United States)

    Corballis, Michael C

    2018-01-01

    Mirror-image confusions are common, especially in children and in some cases of neurological impairment. They can be a special impediment in activities such as reading and writing directional scripts, where mirror-image patterns (such as b and d ) must be distinguished. Treating mirror images as equivalent, though, can also be adaptive in the natural world, which carries no systematic left-right bias and where the same object or event can appear in opposite viewpoints. Mirror-image equivalence and confusion are natural consequences of a bilaterally symmetrical brain. In the course of learning, mirror-image equivalence may be established through a process of symmetrization, achieved through homotopic interhemispheric exchange in the formation of memory circuits. Such circuits would not distinguish between mirror images. Learning to discriminate mirror-image discriminations may depend either on existing brain asymmetries, or on extensive learning overriding the symmetrization process. The balance between mirror-image equivalence and mirror-image discrimination may nevertheless be precarious, with spontaneous confusions or reversals, such as mirror writing, sometimes appearing naturally or as a manifestation of conditions like dyslexia.

  19. Mirror-Image Equivalence and Interhemispheric Mirror-Image Reversal

    Directory of Open Access Journals (Sweden)

    Michael C. Corballis

    2018-04-01

    Full Text Available Mirror-image confusions are common, especially in children and in some cases of neurological impairment. They can be a special impediment in activities such as reading and writing directional scripts, where mirror-image patterns (such as b and d must be distinguished. Treating mirror images as equivalent, though, can also be adaptive in the natural world, which carries no systematic left-right bias and where the same object or event can appear in opposite viewpoints. Mirror-image equivalence and confusion are natural consequences of a bilaterally symmetrical brain. In the course of learning, mirror-image equivalence may be established through a process of symmetrization, achieved through homotopic interhemispheric exchange in the formation of memory circuits. Such circuits would not distinguish between mirror images. Learning to discriminate mirror-image discriminations may depend either on existing brain asymmetries, or on extensive learning overriding the symmetrization process. The balance between mirror-image equivalence and mirror-image discrimination may nevertheless be precarious, with spontaneous confusions or reversals, such as mirror writing, sometimes appearing naturally or as a manifestation of conditions like dyslexia.

  20. Measurements of the personal dose equivalent

    International Nuclear Information System (INIS)

    Scarlat, F.; Scarisoreanu, A.; Badita, E.; Oane, M.; Mitru, E.

    2008-01-01

    Full text: The paper presents the results of measurements related to the personal dose equivalent in the rooms adjacent to NILPRP 7 MeV linear accelerator, by means of the secondary standard chamber T34035 Hp(10). The chamber was calibrated by PTB at S- 137 Cs (E av = 661.6 keV, T 1/2 11050 days) and has N H = 3.17x10 6 Sv/C calibration factor for the personal dose equivalent, Hp(10), at a depth of 10 mm in climatic reference conditions. The measurements were made for the two operation mode of the 7 MeV linac: electrons and bremsstrahlung

  1. Visual Equivalence and Amodal Completion in Cuttlefish.

    Science.gov (United States)

    Lin, I-Rong; Chiao, Chuan-Chin

    2017-01-01

    Modern cephalopods are notably the most intelligent invertebrates and this is accompanied by keen vision. Despite extensive studies investigating the visual systems of cephalopods, little is known about their visual perception and object recognition. In the present study, we investigated the visual processing of the cuttlefish Sepia pharaonis , including visual equivalence and amodal completion. Cuttlefish were trained to discriminate images of shrimp and fish using the operant conditioning paradigm. After cuttlefish reached the learning criteria, a series of discrimination tasks were conducted. In the visual equivalence experiment, several transformed versions of the training images, such as images reduced in size, images reduced in contrast, sketches of the images, the contours of the images, and silhouettes of the images, were used. In the amodal completion experiment, partially occluded views of the original images were used. The results showed that cuttlefish were able to treat the training images of reduced size and sketches as the visual equivalence. Cuttlefish were also capable of recognizing partially occluded versions of the training image. Furthermore, individual differences in performance suggest that some cuttlefish may be able to recognize objects when visual information was partly removed. These findings support the hypothesis that the visual perception of cuttlefish involves both visual equivalence and amodal completion. The results from this research also provide insights into the visual processing mechanisms used by cephalopods.

  2. Structurally Based Therapeutic Evaluation: A Therapeutic and Practical Approach to Teaching Medicinal Chemistry.

    Science.gov (United States)

    Alsharif, Naser Z.; And Others

    1997-01-01

    Explains structurally based therapeutic evaluation of drugs, which uses seven therapeutic criteria in translating chemical and structural knowledge into therapeutic decision making in pharmaceutical care. In a Creighton University (Nebraska) medicinal chemistry course, students apply the approach to solve patient-related therapeutic problems in…

  3. Equivalent properties for perforated plates. An analytical approach

    International Nuclear Information System (INIS)

    Cepkauskas, M.M.; Yang Jianfeng

    2005-01-01

    Structures that contain perforated plates have been a subject of interest in the Nuclear Industry. Steam generators, condensers and reactor internals utilize plates containing holes which act as flow holes or separate structures from flow by using a 'tube bank' design. The equivalent plate method has been beneficial in analyzing perforate plates. Details are found in various papers found in the bibliography. In addition the ASME code addresses perforated plates in Appendix A-8000, but is limited to a triangular hole pattern. This early work performed in this field utilized test data and analytical approaches. This paper is an examination of an analytical approach for determining equivalent plate mechanical and thermal properties. First a patch of the real plate is identified that provides a model for the necessary physical behavior of the plate. The average strain of this patch is obtained by first applying simplified one dimensional mechanical load to the patch, determining stress as a function of position, converting the stress to strain and then integrating the strain over the patch length. This average strain is then equated to the average strain of an equivalent fictitious rectangular patch. This results in obtaining equivalent Young's Modulus and Poison's Ratio for the equivalent plate in all three orthogonal directions. The corresponding equivalent shear modulus in all three directions is then determined. An orthotropic material stress strain matrix relationship is provided for the fictitious properties. By equating the real average strain with the fictitious average strain in matrix form, a stress multiplier is found to convert average fictitious stress to average real stress. This same type of process is repeated for heat conduction coefficients and coefficients of thermal expansion. Results are provided for both a square and triangular hole pattern. Reasonable results are obtained when comparing the effective Young's Modulus and Poison's Ratio with ASME

  4. Investigation of 1-cm dose equivalent for photons behind shielding materials

    International Nuclear Information System (INIS)

    Hirayama, Hideo; Tanaka, Shun-ichi

    1991-03-01

    The ambient dose equivalent at 1-cm depth, assumed equivalent to the 1-cm dose equivalent in practical dose estimations behind shielding slabs of water, concrete, iron or lead for normally incident photons having various energies was calculated by using conversion factors for a slab phantom. It was compared with the 1-cm depth dose calculated with the Monte Carlo code EGS4. It was concluded from this comparison that the ambient dose equivalent calculated by using the conversion factors for the ICRU sphere could be used for the evaluation of the 1-cm dose equivalent for the sphere phantom within 20% errors. Average and practical conversion factors are defined as the conversion factors from exposure to ambient dose equivalent in a finite slab or an infinite one, respectively. They were calculated with EGS4 and the discrete ordinates code PALLAS. The exposure calculated with simple estimation procedures such as point kernel methods can be easily converted to ambient dose equivalent by using these conversion factors. The maximum value between 1 and 30 mfp can be adopted as the conversion factor which depends only on material and incident photon energy. This gives the ambient dose equivalent on the safe side. 13 refs., 7 figs., 2 tabs

  5. Periodic equivalence ratio modulation method and apparatus for controlling combustion instability

    Science.gov (United States)

    Richards, George A.; Janus, Michael C.; Griffith, Richard A.

    2000-01-01

    The periodic equivalence ratio modulation (PERM) method and apparatus significantly reduces and/or eliminates unstable conditions within a combustion chamber. The method involves modulating the equivalence ratio for the combustion device, such that the combustion device periodically operates outside of an identified unstable oscillation region. The equivalence ratio is modulated between preselected reference points, according to the shape of the oscillation region and operating parameters of the system. Preferably, the equivalence ratio is modulated from a first stable condition to a second stable condition, and, alternatively, the equivalence ratio is modulated from a stable condition to an unstable condition. The method is further applicable to multi-nozzle combustor designs, whereby individual nozzles are alternately modulated from stable to unstable conditions. Periodic equivalence ratio modulation (PERM) is accomplished by active control involving periodic, low frequency fuel modulation, whereby low frequency fuel pulses are injected into the main fuel delivery. Importantly, the fuel pulses are injected at a rate so as not to affect the desired time-average equivalence ratio for the combustion device.

  6. Change of annual collective dose equivalent of radiation workers at KURRI

    International Nuclear Information System (INIS)

    Okamoto, Kenichi

    1994-01-01

    The change of exposure dose equivalent of radiation workers at KURRI (Kyoto University Research Reactor Institute) in the past 30 years is reported together with the operational accomplishments. The reactor achieved criticality on June 24, 1964 and reached the normal power of 1000 kW on August 17 of the same year, and the normal power was elevated to 5000 kW on July 16, 1968 until today. The change of the annual effective dose equivalent, the collective dose equivalent, the average annual dose equivalent and the maximum dose equivalent are indicated in the table and the figure. The chronological table on the activities of the reactor is added. (T.H.)

  7. MUTZ-3 derived Langerhans cells in human skin equivalents show differential migration and phenotypic plasticity after allergen or irritant exposure

    Energy Technology Data Exchange (ETDEWEB)

    Kosten, Ilona J.; Spiekstra, Sander W. [Department of Dermatology, VU University Medical Center, Amsterdam (Netherlands); Gruijl, Tanja D. de [Department of Dermatology Medical Oncology, VU University Medical Center, Amsterdam (Netherlands); Gibbs, Susan, E-mail: s.gibbs@acta.nl [Department of Dermatology, VU University Medical Center, Amsterdam (Netherlands); Department of Oral Cell Biology, Academic Center for Dentistry (ACTA), Amsterdam (Netherlands)

    2015-08-15

    After allergen or irritant exposure, Langerhans cells (LC) undergo phenotypic changes and exit the epidermis. In this study we describe the unique ability of MUTZ-3 derived Langerhans cells (MUTZ-LC) to display similar phenotypic plasticity as their primary counterparts when incorporated into a physiologically relevant full-thickness skin equivalent model (SE-LC). We describe differences and similarities in the mechanisms regulating LC migration and plasticity upon allergen or irritant exposure. The skin equivalent consisted of a reconstructed epidermis containing primary differentiated keratinocytes and CD1a{sup +} MUTZ-LC on a primary fibroblast-populated dermis. Skin equivalents were exposed to a panel of allergens and irritants. Topical exposure to sub-toxic concentrations of allergens (nickel sulfate, resorcinol, cinnamaldehyde) and irritants (Triton X-100, SDS, Tween 80) resulted in LC migration out of the epidermis and into the dermis. Neutralizing antibody to CXCL12 blocked allergen-induced migration, whereas anti-CCL5 blocked irritant-induced migration. In contrast to allergen exposure, irritant exposure resulted in cells within the dermis becoming CD1a{sup −}/CD14{sup +}/CD68{sup +} which is characteristic of a phenotypic switch of MUTZ-LC to a macrophage-like cell in the dermis. This phenotypic switch was blocked with anti-IL-10. Mechanisms previously identified as being involved in LC activation and migration in native human skin could thus be reproduced in the in vitro constructed skin equivalent model containing functional LC. This model therefore provides a unique and relevant research tool to study human LC biology in situ under controlled in vitro conditions, and will provide a powerful tool for hazard identification, testing novel therapeutics and identifying new drug targets. - Highlights: • MUTZ-3 derived Langerhans cells integrated into skin equivalents are fully functional. • Anti-CXCL12 blocks allergen-induced MUTZ-LC migration.

  8. Equivalence ratio and constriction effects on RBCC thrust augmentation

    Science.gov (United States)

    Koupriyanov, M.; Etele, J.

    2011-06-01

    A theoretical analysis of a variable area rocket based combined cycle engine with and without simultaneous mixing and combustion is presented. The flowfield is solved using a steady, quasi-one-dimensional, inviscid control volume formulation with combustion effects included via a generalized equilibrium calculation. Compression augmentation is shown to be sensitive to the equivalence ratio within the primary rocket chamber, where ejector section performance is greatest at both low and high equivalence ratios but near a minimum at stoichiometric conditions. The thrust generated by the RBCC engine compared to that generated by the same rocket in isolation can be increased by as much as 12% at constriction ratios of between 45% and 50%. Thrust augmentation is also shown to vary with equivalence ratio, where for a fixed geometry the maximum thrust is generated at equivalence ratios slightly below unity.

  9. Off-axis dose equivalent due to secondary neutrons from uniform scanning proton beams during proton radiotherapy

    Science.gov (United States)

    Islam, M. R.; Collums, T. L.; Zheng, Y.; Monson, J.; Benton, E. R.

    2013-11-01

    The production of secondary neutrons is an undesirable byproduct of proton therapy and it is important to quantify the contribution from secondary neutrons to patient dose received outside the treatment volume. The purpose of this study is to investigate the off-axis dose equivalent from secondary neutrons experimentally using CR-39 plastic nuclear track detectors (PNTD) at ProCure Proton Therapy Center, Oklahoma City, OK. In this experiment, we placed several layers of CR-39 PNTD laterally outside the treatment volume inside a phantom and in air at various depths and angles with respect to the primary beam axis. Three different proton beams with max energies of 78, 162 and 226 MeV and 4 cm modulation width, a 5 cm diameter brass aperture, and a small snout located 38 cm from isocenter were used for the entire experiment. Monte Carlo simulations were also performed based on the experimental setup using a simplified snout configuration and the FLUKA Monte Carlo radiation transport code. The measured ratio of secondary neutron dose equivalent to therapeutic primary proton dose (H/D) ranged from 0.3 ± 0.08 mSv Gy-1 for 78 MeV proton beam to 37.4 ± 2.42 mSv Gy-1 for 226 MeV proton beam. Both experiment and simulation showed a similar decreasing trend in dose equivalent with distance to the central axis and the magnitude varied by a factor of about 2 in most locations. H/D was found to increase as the energy of the primary proton beam increased and higher H/D was observed at 135° compared to 45° and 90°. The overall higher H/D in air indicates the predominance of external neutrons produced in the nozzle rather than inside the body.

  10. Off-axis dose equivalent due to secondary neutrons from uniform scanning proton beams during proton radiotherapy

    International Nuclear Information System (INIS)

    Islam, M R; Collums, T L; Monson, J; Benton, E R; Zheng, Y

    2013-01-01

    The production of secondary neutrons is an undesirable byproduct of proton therapy and it is important to quantify the contribution from secondary neutrons to patient dose received outside the treatment volume. The purpose of this study is to investigate the off-axis dose equivalent from secondary neutrons experimentally using CR-39 plastic nuclear track detectors (PNTD) at ProCure Proton Therapy Center, Oklahoma City, OK. In this experiment, we placed several layers of CR-39 PNTD laterally outside the treatment volume inside a phantom and in air at various depths and angles with respect to the primary beam axis. Three different proton beams with max energies of 78, 162 and 226 MeV and 4 cm modulation width, a 5 cm diameter brass aperture, and a small snout located 38 cm from isocenter were used for the entire experiment. Monte Carlo simulations were also performed based on the experimental setup using a simplified snout configuration and the FLUKA Monte Carlo radiation transport code. The measured ratio of secondary neutron dose equivalent to therapeutic primary proton dose (H/D) ranged from 0.3 ± 0.08 mSv Gy −1  for 78 MeV proton beam to 37.4 ± 2.42 mSv Gy −1  for 226 MeV proton beam. Both experiment and simulation showed a similar decreasing trend in dose equivalent with distance to the central axis and the magnitude varied by a factor of about 2 in most locations. H/D was found to increase as the energy of the primary proton beam increased and higher H/D was observed at 135° compared to 45° and 90°. The overall higher H/D in air indicates the predominance of external neutrons produced in the nozzle rather than inside the body. (paper)

  11. Multi-rate equivalents of cyclo-static synchronous dataflow graphs

    NARCIS (Netherlands)

    de Groote, Robert; Holzenspies, P.K.F.; Kuper, Jan; Smit, Gerardus Johannes Maria

    In this paper, we present a transformation that takes a cyclo-static dataflow (CSDF) graph and produces an equivalent multi-rate synchronous dataflow (MRSDF) graph. This fills a gap in existing analysis techniques for synchronous dataflow graphs; transformations into equivalent homogeneous

  12. Equivalence classification by California sea lions using class-specific reinforcers.

    OpenAIRE

    Kastak, C R; Schusterman, R J; Kastak, D

    2001-01-01

    The ability to group dissimilar stimuli into categories on the basis of common stimulus relations (stimulus equivalence) or common functional relations (functional equivalence) has been convincingly demonstrated in verbally competent subjects. However, there are investigations with verbally limited humans and with nonhuman animals that suggest that the formation and use of classification schemes based on equivalence does not depend on linguistic skills. The present investigation documented th...

  13. Decompositional equivalence: A fundamental symmetry underlying quantum theory

    OpenAIRE

    Fields, Chris

    2014-01-01

    Decompositional equivalence is the principle that there is no preferred decomposition of the universe into subsystems. It is shown here, by using simple thought experiments, that quantum theory follows from decompositional equivalence together with Landauer's principle. This demonstration raises within physics a question previously left to psychology: how do human - or any - observers agree about what constitutes a "system of interest"?

  14. Cryogenic test of the equivalence principle

    International Nuclear Information System (INIS)

    Worden, P.W. Jr.

    1976-01-01

    The weak equivalence principle is the hypothesis that the ratio of internal and passive gravitational mass is the same for all bodies. A greatly improved test of this principle is possible in an orbiting satellite. The most promising experiments for an orbital test are adaptations of the Galilean free-fall experiment and the Eotvos balance. Sensitivity to gravity gradient noise, both from the earth and from the spacecraft, defines a limit to the sensitivity in each case. This limit is generally much worse for an Eotvos balance than for a properly designed free-fall experiment. The difference is related to the difficulty of making a balance sufficiently isoinertial. Cryogenic technology is desirable to take full advantage of the potential sensitivity, but tides in the liquid helium refrigerant may produce a gravity gradient that seriously degrades the ultimate sensitivity. The Eotvos balance appears to have a limiting sensitivity to relative difference of rate of fall of about 2 x 10 -14 in orbit. The free-fall experiment is limited by helium tide to about 10 -15 ; if the tide can be controlled or eliminated the limit may approach 10 -18 . Other limitations to equivalence principle experiments are discussed. An experimental test of some of the concepts involved in the orbital free-fall experiment is continuing. The experiment consists in comparing the motions of test masses levitated in a superconducting magnetic bearing, and is itself a sensitive test of the equivalence principle. At present the levitation magnets, position monitors and control coils have been tested and major noise sources identified. A measurement of the equivalence principle is postponed pending development of a system for digitizing data. The experiment and preliminary results are described

  15. Equivalence, commensurability, value

    DEFF Research Database (Denmark)

    Albertsen, Niels

    2017-01-01

    Deriving value in Capital Marx uses three commensurability arguments (CA1-3). CA1 establishes equivalence in exchange as exchangeability with the same third commodity. CA2 establishes value as common denominator in commodities: embodied abstract labour. CA3 establishes value substance...... as commonality of labour: physiological labour. Tensions between these logics have permeated Marxist interpretations of value. Some have supported value as embodied labour (CA2, 3), others a monetary theory of value and value as ‘pure’ societal abstraction (ultimately CA1). They all are grounded in Marx....

  16. On the equivalence of GPD representations

    International Nuclear Information System (INIS)

    Müller, Dieter; Semenov-Tian-Shansky, Kirill

    2016-01-01

    Phenomenological representations of generalized parton distributions (GPDs) implementing the non-trivial field theoretical requirements are employed in the present day strategies for extracting of hadron structure information encoded in GPDs from the observables of hard exclusive reactions. Showing out the equivalence of various GPD representations can help to get more insight into GPD properties and allow to build up flexible GPD models capable of satisfactory description of the whole set of available experimental data. Below we review the mathematical aspects of establishing equivalence between the the double partial wave expansion of GPDs in the conformal partial waves and in the t-channel SO(3) partial waves and the double distribution representation of GPDs

  17. Equivalent statistics and data interpretation.

    Science.gov (United States)

    Francis, Gregory

    2017-08-01

    Recent reform efforts in psychological science have led to a plethora of choices for scientists to analyze their data. A scientist making an inference about their data must now decide whether to report a p value, summarize the data with a standardized effect size and its confidence interval, report a Bayes Factor, or use other model comparison methods. To make good choices among these options, it is necessary for researchers to understand the characteristics of the various statistics used by the different analysis frameworks. Toward that end, this paper makes two contributions. First, it shows that for the case of a two-sample t test with known sample sizes, many different summary statistics are mathematically equivalent in the sense that they are based on the very same information in the data set. When the sample sizes are known, the p value provides as much information about a data set as the confidence interval of Cohen's d or a JZS Bayes factor. Second, this equivalence means that different analysis methods differ only in their interpretation of the empirical data. At first glance, it might seem that mathematical equivalence of the statistics suggests that it does not matter much which statistic is reported, but the opposite is true because the appropriateness of a reported statistic is relative to the inference it promotes. Accordingly, scientists should choose an analysis method appropriate for their scientific investigation. A direct comparison of the different inferential frameworks provides some guidance for scientists to make good choices and improve scientific practice.

  18. 40 CFR 133.105 - Treatment equivalent to secondary treatment.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 21 2010-07-01 2010-07-01 false Treatment equivalent to secondary treatment. 133.105 Section 133.105 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS SECONDARY TREATMENT REGULATION § 133.105 Treatment equivalent to secondary treatment...

  19. 30 CFR 90.206 - Approved sampling devices; equivalent concentrations.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approved sampling devices; equivalent... LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-COAL MINERS WHO HAVE EVIDENCE OF THE DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures § 90.206 Approved sampling devices; equivalent...

  20. Skin Dose Equivalent Measurement from Neutron-Deficient Isotopes

    International Nuclear Information System (INIS)

    Hsu, Hsiao-Hua; Costigan, Steve A.; Romero, Leonard L.; Whicker, Jeffrey J.

    1997-12-01

    Neutron-deficient-isotopes decay via positron emission and/or electron capture often followed by x-ray, gamma-ray, and 0.511 MeV photons from positron annihilation. For cases of significant area and/or personnel contamination with these isotopes, determination of skin dose equivalent (SDE) is required by 10CFR835. For assessment of SDE, we evaluated the MICROSPEC-2(TM) system manufactured by Bubble Technology Industries of Canada which uses three different probes for dose measurement. We used two probes: (1) the X-probe which measures lower energy (4 - 120 keV) photon energy distributions and determines deep dose equivalent, SDE and dose equivalent to eyes, and (2) the B-probe which measures electron (positron) energy distributions, and determines skin dose equivalent. Also, the measured photon and beta spectra can be used to identify radioactive isotopes in the contaminated area. Measurements with several neutron-deficient sources showed that this system provided reasonably accurate SDE rate measurements when compared with calculated benchmark SDE rates with an average percent difference of 40%. Variations were expected because of differences between the assumed geometries used by MlCROSPEC-2 and the calculations when compared to the measurement conditions

  1. Nanoparticle-mediated delivery of pioglitazone enhances therapeutic neovascularization in a murine model of hindlimb ischemia.

    Science.gov (United States)

    Nagahama, Ryoji; Matoba, Tetsuya; Nakano, Kaku; Kim-Mitsuyama, Shokei; Sunagawa, Kenji; Egashira, Kensuke

    2012-10-01

    Critical limb ischemia is a severe form of peripheral artery disease (PAD) for which neither surgical revascularization nor endovascular therapy nor current medicinal therapy has sufficient therapeutic effects. Peroxisome proliferator activated receptor-γ agonists present angiogenic activity in vitro; however, systemic administration of peroxisome proliferator-activated receptor-γ agonists is hampered by its side effects, including heart failure. Here, we demonstrate that the nanoparticle (NP)-mediated delivery of the peroxisome proliferator activated receptor-γ agonist pioglitazone enhances its therapeutic efficacy on ischemia-induced neovascularization in a murine model. In a nondiabetic murine model of hindlimb ischemia, a single intramuscular injection of pioglitazone-incorporated NP (1 µg/kg) into ischemic muscles significantly improved the blood flow recovery in the ischemic limbs, significantly increasing the number of CD31-positive capillaries and α-smooth muscle actin-positive arterioles. The therapeutic effects of pioglitazone-incorporated NP were diminished by the peroxisome proliferator activated receptor-γ antagonist GW9662 and were not observed in endothelial NO synthase-deficient mice. Pioglitazone-incorporated NP induced endothelial NO synthase phosphorylation, as demonstrated by Western blot analysis, as well as expression of multiple angiogenic growth factors in vivo, including vascular endothelial growth factor-A, vascular endothelial growth factor-B, and fibroblast growth factor-1, as demonstrated by real-time polymerase chain reaction. Intramuscular injection of pioglitazone (1 µg/kg) was ineffective, and oral administration necessitated a >500 μg/kg per day dose to produce therapeutic effects equivalent to those of pioglitazone-incorporated NP. NP-mediated drug delivery is a novel modality that may enhance the effectiveness of therapeutic neovascularization, surpassing the effectiveness of current treatments for peripheral artery

  2. Calculation simulation of equivalent irradiation swelling for dispersion nuclear fuel

    International Nuclear Information System (INIS)

    Cai Wei; Zhao Yunmei; Gong Xin; Ding Shurong; Huo Yongzhong

    2015-01-01

    The dispersion nuclear fuel was regarded as a kind of special particle composites. Assuming that the fuel particles are periodically distributed in the dispersion nuclear fuel meat, the finite element model to calculate its equivalent irradiation swelling was developed with the method of computational micro-mechanics. Considering irradiation swelling in the fuel particles and the irradiation hardening effect in the metal matrix, the stress update algorithms were established respectively for the fuel particles and metal matrix. The corresponding user subroutines were programmed, and the finite element simulation of equivalent irradiation swelling for the fuel meat was performed in Abaqus. The effects of the particle size and volume fraction on the equivalent irradiation swelling were investigated, and the fitting formula of equivalent irradiation swelling was obtained. The results indicate that the main factors to influence equivalent irradiation swelling of the fuel meat are the irradiation swelling and volume fraction of fuel particles. (authors)

  3. Establishment of an equivalence acceptance criterion for accelerated stability studies.

    Science.gov (United States)

    Burdick, Richard K; Sidor, Leslie

    2013-01-01

    In this article, the use of statistical equivalence testing for providing evidence of process comparability in an accelerated stability study is advocated over the use of a test of differences. The objective of such a study is to demonstrate comparability by showing that the stability profiles under nonrecommended storage conditions of two processes are equivalent. Because it is difficult at accelerated conditions to find a direct link to product specifications, and hence product safety and efficacy, an equivalence acceptance criterion is proposed that is based on the statistical concept of effect size. As with all statistical tests of equivalence, it is important to collect input from appropriate subject-matter experts when defining the acceptance criterion.

  4. Graphene-based THz modulator analyzed by equivalent circuit model

    DEFF Research Database (Denmark)

    Xiao, Binggang; Chen, Jing; Xie, Zhiyi

    2016-01-01

    A terahertz (THz) modulator based on graphene is proposed and analysed by use of equivalent transmission line of a homogeneous mediumand the local anisotropic model of the graphene conductivity. The result calculated by the equivalent circuit is consistent with that obtained byFresnel transfer...

  5. Asymptotically double lacunry equivalent sequences defined by Orlicz functions

    Directory of Open Access Journals (Sweden)

    Ayhan Esi

    2014-04-01

    Full Text Available This paper presents the following definition which is natural combition of the definition for asymptotically equivalent and Orlicz function. The two nonnegative double sequences x=(x_{k,l} and y=(y_{k,l} are said to be M-asymptotically double equivalent to multiple L provided that for every ε>0, P-lim_{k,l}M(((|((x_{k,l}/(y_{k,l}-L|/ρ=0, for some ρ>0, (denoted by x∽y and simply M-asymptotically double equivalent if L=1. Also we give some new concepts related to this definition and some inclusion theorems.

  6. Fiscal adjustments in Europe and Ricardian equivalence

    Directory of Open Access Journals (Sweden)

    V. DE BONIS

    1998-09-01

    Full Text Available According to the ‘Ricardian’ equivalence hypothesis, consumption is dependent on permanent disposable income and current deficits are equivalent to future tax payments. This hypothesis is tested on 14 European countries in the 1990s. The relationships between private sector savings and general government deficit, and the GDP growth rate and the unemployment rate are determined. The results show the change in consumers' behaviour with respect to government deficit, and that expectations of an increase in future wealth are no longer associated with a decrease in deficit.

  7. A neutron dose equivalent meter at CAEP

    International Nuclear Information System (INIS)

    Tian Shihai; Lu Yan; Wang Heyi; Yuan Yonggang; Chen Xu

    2012-01-01

    The measurement of neutron dose equivalent has been a widespread need in industry and research. In this paper, aimed at improving the accuracy of neutron dose equivalent meter: a neutron dose counter is simulated with MCNP5, and the energy response curve is optimized. The results show that the energy response factor is from 0.2 to 1.8 for neutrons in the energy range of 2.53×10 -8 MeV to 10 MeV Compared with other related meters, it turns that the design of this meter is right. (authors)

  8. Alexander-equivalent Zariski pairs of irreducible sextics

    DEFF Research Database (Denmark)

    Eyral, Christophe; Oka, Mutsuo

    2009-01-01

    The existence of Alexander-equivalent Zariski pairs dealing with irreducible curves of degree 6 was proved by Degtyarev. However, no explicit example of such a pair is available (only the existence is known) in the literature. In this paper, we construct the first concrete example.......The existence of Alexander-equivalent Zariski pairs dealing with irreducible curves of degree 6 was proved by Degtyarev. However, no explicit example of such a pair is available (only the existence is known) in the literature. In this paper, we construct the first concrete example....

  9. The equivalence myth of quantum mechanics-part II

    Science.gov (United States)

    Muller, F. A.

    The author endeavours to show two things: first, that Schrödingers (and Eckarts) demonstration in March (September) 1926 of the equivalence of matrix mechanics, as created by Heisenberg, Born, Jordan and Dirac in 1925, and wave mechanics, as created by Schrödinger in 1926, is not foolproof; and second, that it could not have been foolproof, because at the time matrix mechanics and wave mechanics were neither mathematically nor empirically equivalent. That they were is the Equivalence Myth. In order to make the theories equivalent and to prove this, one has to leave the historical scene of 1926 and wait until 1932, when von Neumann finished his magisterial edifice. During the period 1926-1932 the original families of mathematical structures of matrix mechanics and of wave mechanics were stretched, parts were chopped off and novel structures were added. To Procrustean places we go, where we can demonstrate the mathematical, empirical and ontological equivalence of 'the final versions of' matrix mechanics and wave mechanics. The present paper claims to be a comprehensive analysis of one of the pivotal papers in the history of quantum mechanics: Schrödingers equivalence paper. Since the analysis is performed from the perspective of Suppes structural view ('semantic view') of physical theories, the present paper can be regarded not only as a morsel of the internal history of quantum mechanics, but also as a morsel of applied philosophy of science. The paper is self-contained and presupposes only basic knowledge of quantum mechanics. For reasons of length, the paper is published in two parts; Part I appeared in the previous issue of this journal. Section 1 contains, besides an introduction, also the papers five claims and a preview of the arguments supporting these claims; so Part I, Section 1 may serve as a summary of the paper for those readers who are not interested in the detailed arguments.

  10. Testing the principle of equivalence by solar neutrinos

    International Nuclear Information System (INIS)

    Minakata, Hisakazu; Washington Univ., Seattle, WA; Nunokawa, Hiroshi; Washington Univ., Seattle, WA

    1994-04-01

    We discuss the possibility of testing the principle of equivalence with solar neutrinos. If there exists a violation of the equivalence principle quarks and leptons with different flavors may not universally couple with gravity. The method we discuss employs a quantum mechanical phenomenon of neutrino oscillation to probe into the non-university of the gravitational couplings of neutrinos. We develop an appropriate formalism to deal with neutrino propagation under the weak gravitational fields of the sun in the presence of the flavor mixing. We point out that solar neutrino observation by the next generation water Cherenkov detectors can improve the existing bound on violation of the equivalence principle by 3-4 orders of magnitude if the nonadiabatic Mikheyev-Smirnov-Wolfenstein mechanism is the solution to the solar neutrino problem

  11. Lumped-parameters equivalent circuit for condenser microphones modeling.

    Science.gov (United States)

    Esteves, Josué; Rufer, Libor; Ekeom, Didace; Basrour, Skandar

    2017-10-01

    This work presents a lumped parameters equivalent model of condenser microphone based on analogies between acoustic, mechanical, fluidic, and electrical domains. Parameters of the model were determined mainly through analytical relations and/or finite element method (FEM) simulations. Special attention was paid to the air gap modeling and to the use of proper boundary condition. Corresponding lumped-parameters were obtained as results of FEM simulations. Because of its simplicity, the model allows a fast simulation and is readily usable for microphone design. This work shows the validation of the equivalent circuit on three real cases of capacitive microphones, including both traditional and Micro-Electro-Mechanical Systems structures. In all cases, it has been demonstrated that the sensitivity and other related data obtained from the equivalent circuit are in very good agreement with available measurement data.

  12. Testing the principle of equivalence by solar neutrinos

    International Nuclear Information System (INIS)

    Minakata, H.; Nunokawa, H.

    1995-01-01

    We discuss the possibility of testing the principle of equivalence with solar neutrinos. If there exists a violation of the equivalence principle, quarks and leptons with different flavors may not universally couple with gravity. The method we discuss employs the quantum mechanical phenomenon of neutrino oscillation to probe into the nonuniversality of the gravitational couplings of neutrinos. We develop an appropriate formalism to deal with neutrino propagation under the weak gravitational fields of the Sun in the presence of the flavor mixing. We point out that solar neutrino observation by the next generation water Cherenkov detectors can place stringent bounds on the violation of the equivalence principle to 1 part in 10 15 --10 16 if the nonadiabatic Mikheyev-Smirnov-Wolfenstein mechanism is the solution to the solar neutrino problem

  13. Comments on field equivalence principles

    DEFF Research Database (Denmark)

    Appel-Hansen, Jørgen

    1987-01-01

    It is pointed Out that often-used arguments based on a short-circuit concept in presentations of field equivalence principles are not correct. An alternative presentation based on the uniqueness theorem is given. It does not contradict the results obtained by using the short-circuit concept...

  14. Dose equivalent distributions in the AAEC total body nitrogen facility

    International Nuclear Information System (INIS)

    Allen, B.J.; Bailey, G.M.; McGregor, B.J.

    1985-01-01

    The incident neutron dose equivalent in the AAEC total body nitrogen facility is measured by a calibrated remmeter. Dose equivalent rates and distributions are calculated by Monte Carlo techniques which take account of the secondary neutron flux from the collimator. Experiment and calculation are found to be in satisfactory agreement. The effective dose equivalent per exposure is determined by weighting organ doses, and the potential detriment per exposure is calculated from ICRP risk factors

  15. Dose distribution around ion track in tissue equivalent material

    International Nuclear Information System (INIS)

    Zhang Wenzhong; Guo Yong; Luo Yisheng

    2007-01-01

    Objective: To study the energy deposition micro-specialty of ions in body-tissue or tissue equivalent material (TEM). Methods: The water vapor was determined as the tissue equivalent material, based on the analysis to the body-tissue, and Monte Carlo method was used to simulate the behavior of proton in the tissue equivalent material. Some features of the energy deposition micro-specialty of ion in tissue equivalent material were obtained through the analysis to the data from calculation. Results: The ion will give the energy by the way of excitation and ionization in material, then the secondary electrons will be generated in the progress of ionization, these electron will finished ions energy deposition progress. When ions deposited their energy, large amount energy will be in the core of tracks, and secondary electrons will devote its' energy around ion track, the ion dose distribution is then formed in TEM. Conclusions: To know biological effects of radiation , the research to dose distribution of ions is of importance(significance). (authors)

  16. The radiobiology of boron neutron capture therapy: Are ''photon-equivalent'' doses really photon-equivalent?

    International Nuclear Information System (INIS)

    Coderre, J.A.; Diaz, A.Z.; Ma, R.

    2001-01-01

    Boron neutron capture therapy (BNCT) produces a mixture of radiation dose components. The high-linear energy transfer (LET) particles are more damaging in tissue than equal doses of low-LET radiation. Each of the high-LET components can multiplied by an experimentally determined factor to adjust for the increased biological effectiveness and the resulting sum expressed in photon-equivalent units (Gy-Eq). BNCT doses in photon-equivalent units are based on a number of assumptions. It may be possible to test the validity of these assumptions and the accuracy of the calculated BNCT doses by 1) comparing the effects of BNCT in other animal or biological models where the effects of photon radiation are known, or 2) if there are endpoints reached in the BNCT dose escalation clinical trials that can be related to the known response to photons of the tissue in question. The calculated Gy-Eq BNCT doses delivered to dogs and to humans with BPA and the epithermal neutron beam of the Brookhaven Medical Research Reactor were compared to expected responses to photon irradiation. The data indicate that Gy-Eq doses in brain may be underestimated. Doses to skin are consistent with the expected response to photons. Gy-Eq doses to tumor are significantly overestimated. A model system of cells in culture irradiated at various depths in a lucite phantom using the epithermal beam is under development. Preliminary data indicate that this approach can be used to detect differences in the relative biological effectiveness of the beam. The rat 9L gliosarcoma cell survival data was converted to photon-equivalent doses using the same factors assumed in the clinical studies. The results superimposed on the survival curve derived from irradiation with Cs-137 photons indicating the potential utility of this model system. (author)

  17. REFractions: The Representing Equivalent Fractions Game

    Science.gov (United States)

    Tucker, Stephen I.

    2014-01-01

    Stephen Tucker presents a fractions game that addresses a range of fraction concepts including equivalence and computation. The REFractions game also improves students' fluency with representing, comparing and adding fractions.

  18. Expression of proliferative and inflammatory markers in a full-thickness human skin equivalent following exposure to the model sulfur mustard vesicant, 2-chloroethyl ethyl sulfide

    International Nuclear Information System (INIS)

    Black, Adrienne T.; Hayden, Patrick J.; Casillas, Robert P.; Heck, Diane E.; Gerecke, Donald R.; Sinko, Patrick J.; Laskin, Debra L.; Laskin, Jeffrey D.

    2010-01-01

    Sulfur mustard is a potent vesicant that induces inflammation, edema and blistering following dermal exposure. To assess molecular mechanisms mediating these responses, we analyzed the effects of the model sulfur mustard vesicant, 2-chloroethyl ethyl sulfide, on EpiDerm-FT TM , a commercially available full-thickness human skin equivalent. CEES (100-1000 μM) caused a concentration-dependent increase in pyknotic nuclei and vacuolization in basal keratinocytes; at high concentrations (300-1000 μM), CEES also disrupted keratin filament architecture in the stratum corneum. This was associated with time-dependent increases in expression of proliferating cell nuclear antigen, a marker of cell proliferation, and poly(ADP-ribose) polymerase (PARP) and phosphorylated histone H2AX, markers of DNA damage. Concentration- and time-dependent increases in mRNA and protein expression of eicosanoid biosynthetic enzymes including COX-2, 5-lipoxygenase, microsomal PGE 2 synthases, leukotriene (LT) A 4 hydrolase and LTC 4 synthase were observed in CEES-treated skin equivalents, as well as in antioxidant enzymes, glutathione S-transferases A1-2 (GSTA1-2), GSTA3 and GSTA4. These data demonstrate that CEES induces rapid cellular damage, cytotoxicity and inflammation in full-thickness skin equivalents. These effects are similar to human responses to vesicants in vivo and suggest that the full thickness skin equivalent is a useful in vitro model to characterize the biological effects of mustards and to develop potential therapeutics.

  19. Equivalence groups of (2+1) dimensional diffusion equation

    OpenAIRE

    Özer, Saadet

    2017-01-01

    If a given set of differential equations contain somearbitrary functions, parameters, we have in fact a family of sets of equationsof the same structure. Almost all field equations of classical physichs havethis property, representing different materials with various paramaters.  Equivalence groups are defined as the groupof transformations which leave a given family of differential equationsinvariant. Therefore, equivalence group of family of differential equations isan important area within...

  20. Teaching Brain-Behavior Relations Economically with Stimulus Equivalence Technology

    Science.gov (United States)

    Fienup, Daniel M.; Covey, Daniel P.; Critchfield, Thomas S.

    2010-01-01

    Instructional interventions based on stimulus equivalence provide learners with the opportunity to acquire skills that are not directly taught, thereby improving the efficiency of instructional efforts. The present report describes a study in which equivalence-based instruction was used to teach college students facts regarding brain anatomy and…

  1. Local unitary versus local Clifford equivalence of stabilizer and graph states

    International Nuclear Information System (INIS)

    Zeng, Bei; Chung, Hyeyoun; Cross, Andrew W.; Chuang, Isaac L.

    2007-01-01

    The equivalence of stabilizer states under local transformations is of fundamental interest in understanding properties and uses of entanglement. Two stabilizer states are equivalent under the usual stochastic local operations and classical communication criterion if and only if they are equivalent under local unitary (LU) operations. More surprisingly, under certain conditions, two LU-equivalent stabilizer states are also equivalent under local Clifford (LC) operations, as was shown by Van den Nest et al. [Phys. Rev. A 71, 062323 (2005)]. Here, we broaden the class of stabilizer states for which LU equivalence implies LC equivalence (LU LC) to include all stabilizer states represented by graphs with cycles of length neither 3 nor 4. To compare our result with Van den Nest et al.'s, we show that any stabilizer state of distance δ=2 is beyond their criterion. We then further prove that LU LC holds for a more general class of stabilizer states of δ=2. We also explicitly construct graphs representing δ>2 stabilizer states which are beyond their criterion: we identify all 58 graphs with up to 11 vertices and construct graphs with 2 m -1 (m≥4) vertices using quantum error-correcting codes which have non-Clifford transversal gates

  2. An equivalent body surface charge model representing three-dimensional bioelectrical activity

    Science.gov (United States)

    He, B.; Chernyak, Y. B.; Cohen, R. J.

    1995-01-01

    A new surface-source model has been developed to account for the bioelectrical potential on the body surface. A single-layer surface-charge model on the body surface has been developed to equivalently represent bioelectrical sources inside the body. The boundary conditions on the body surface are discussed in relation to the surface-charge in a half-space conductive medium. The equivalent body surface-charge is shown to be proportional to the normal component of the electric field on the body surface just outside the body. The spatial resolution of the equivalent surface-charge distribution appears intermediate between those of the body surface potential distribution and the body surface Laplacian distribution. An analytic relationship between the equivalent surface-charge and the surface Laplacian of the potential was found for a half-space conductive medium. The effects of finite spatial sampling and noise on the reconstruction of the equivalent surface-charge were evaluated by computer simulations. It was found through computer simulations that the reconstruction of the equivalent body surface-charge from the body surface Laplacian distribution is very stable against noise and finite spatial sampling. The present results suggest that the equivalent body surface-charge model may provide an additional insight to our understanding of bioelectric phenomena.

  3. Existence and equivalence of twisted products on a symplectic manifold

    International Nuclear Information System (INIS)

    Lichnerowicz, A.

    1979-01-01

    The twisted products play an important role in Quantum Mechanics. A distinction is introduced between Vey *sub(γ) products and strong Vey *sub(γ) products and it is proved that each *sub(γ) product is equivalent to a Vey *sub(γ) product. If b 3 (W) = 0, the symplectic manifold (W,F) admits strong Vey *sub(Gn) products. If b 2 (W) = 0, all *sub(γ) products are equivalent as well as the Vey Lie algebras. In the general case the formal Lie algebras are characterized which are generated by a *sub(γ) product and it proved that the existance of a *sub(γ)-product is equivalent to the existance of a formal Lie algebra infinitesimally equivalent to a Vey Lie algebra at the first order. (Auth.)

  4. Local equivalence, surface-code states, and matroids

    International Nuclear Information System (INIS)

    Sarvepalli, Pradeep; Raussendorf, Robert

    2010-01-01

    Recently, Ji et al. disproved the local-unitary-local Clifford (LU-LC) conjecture and showed that the local unitary (LU) and local Clifford (LC) equivalence classes of the stabilizer states are not always the same. Despite the fact that this settles the LU-LC conjecture, a sufficient condition for stabilizer states that violate the LU-LC conjecture is not known. In this paper, we investigate further the properties of stabilizer states with respect to local equivalence. Our first result shows that there exist infinitely many stabilizer states that violate the LU-LC conjecture. In particular, we show that for all numbers of qubits n≥28, there exist distance-two stabilizer states which are counterexamples to the LU-LC conjecture. We prove that, for all odd n≥195, there exist stabilizer states with distance greater than two that are LU equivalent but not LC equivalent. Two important classes of stabilizer states that are of great interest in quantum computation are the cluster states and stabilizer states of the surface codes. We show that, under some minimal restrictions, both these classes of states preclude any counterexamples. In this context, we also show that the associated surface codes do not have any encoded non-Clifford transversal gates. We characterize the Calderbank-Shor-Steane (CSS) surface-code states in terms of a class of minor closed binary matroids. In addition to making a connection to an important open problem in binary matroid theory, this characterization does in some cases provide an efficient test for CSS states that are not counterexamples.

  5. Microcystin-LR equivalent concentrations in fish tissue during a ...

    African Journals Online (AJOL)

    The effects of a decomposing cyanobacteria bloom on water quality and the accumulation of microcystin-LR equivalent toxin in fish at Loskop Dam were studied in May 2012. Enzyme-linked immunosorbent assay [ELISA] was used to confirm the presence of microcystin-LR equivalent in the water and to determine the ...

  6. 29 CFR 4.170 - Furnishing fringe benefits or equivalents.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Furnishing fringe benefits or equivalents. 4.170 Section 4... Standards Compliance with Compensation Standards § 4.170 Furnishing fringe benefits or equivalents. (a) General. Fringe benefits required under the Act shall be furnished, separate from and in addition to the...

  7. Derivation of Accident-Specific Material-at-Risk Equivalency Factors

    Energy Technology Data Exchange (ETDEWEB)

    Jason P. Andrus; Dr. Chad L. Pope

    2012-05-01

    A novel method for calculating material at risk (MAR) dose equivalency developed at the Idaho National Laboratory (INL) now allows for increased utilization of dose equivalency for facility MAR control. This method involves near-real time accounting for the use of accident and material specific release and transport. It utilizes all information from the committed effective dose equation and the five factor source term equation to derive dose equivalency factors which can be used to establish an overall facility or process MAR limit. The equivalency factors allow different nuclide spectrums to be compared for their respective dose consequences by relating them to a specific quantity of an identified reference nuclide. The ability to compare spectrums to a reference limit ensures that MAR limits are in fact bounding instead of attempting to establish a representative or bounding spectrum which may lead to unintended or unanalyzed configurations. This methodology is then coupled with a near real time material tracking system which allows for accurate and timely material composition information and corresponding MAR equivalency values. The development of this approach was driven by the complex nature of processing operations in some INL facilities. This type of approach is ideally suited for facilities and processes where the composition of the MAR and possible release mechanisms change frequently but in well defined fashions and in a batch-type nature.

  8. Equivalent circuit analysis of terahertz metamaterial filters

    KAUST Repository

    Zhang, Xueqian

    2011-01-01

    An equivalent circuit model for the analysis and design of terahertz (THz) metamaterial filters is presented. The proposed model, derived based on LMC equivalent circuits, takes into account the detailed geometrical parameters and the presence of a dielectric substrate with the existing analytic expressions for self-inductance, mutual inductance, and capacitance. The model is in good agreement with the experimental measurements and full-wave simulations. Exploiting the circuit model has made it possible to predict accurately the resonance frequency of the proposed structures and thus, quick and accurate process of designing THz device from artificial metamaterials is offered. ©2011 Chinese Optics Letters.

  9. Topological equivalence of nonlinear autonomous dynamical systems

    International Nuclear Information System (INIS)

    Nguyen Huynh Phan; Tran Van Nhung

    1995-12-01

    We show in this paper that the autonomous nonlinear dynamical system Σ(A,B,F): x' = Ax+Bu+F(x) is topologically equivalent to the linear dynamical system Σ(A,B,O): x' = Ax+Bu if the projection of A on the complement in R n of the controllable vectorial subspace is hyperbolic and if lipschitz constant of F is sufficiently small ( * ) and F(x) = 0 when parallel x parallel is sufficiently large ( ** ). In particular, if Σ(A,B,O) is controllable, it is topologically equivalent to Σ(A,B,F) when it is only that F satisfy ( ** ). (author). 18 refs

  10. Medial epiphyseal fracture-detachment of the sternoclavicular joint with posterior displacement in a judo athlete - equivalent of posterior sternoclavicular dislocation

    Directory of Open Access Journals (Sweden)

    Rui Pimenta

    2013-04-01

    Full Text Available Posterior sternoclavicular dislocation is a rare traumatic injury that presents a potential risk of injury to mediastinal structures. The diagnosis is fundamentally clinical and treatment is done on an emergency basis. The authors report the clinical case of a young judo athlete with post-traumatic medial epiphyseal fracture-detachment, with posterior displacement (lesion equivalent to posterior sternoclavicular dislocation at pediatric ages. He underwent open reduction and ligament repair by means of a mini-anchor.The radiological and clinical outcome was excellent, and the athlete returned to his sports activity without limitations. We discuss the particular features of this pathological condition, along with the different therapeutic approaches and their complications

  11. An Analytical Model of Leakage Neutron Equivalent Dose for Passively-Scattered Proton Radiotherapy and Validation with Measurements

    International Nuclear Information System (INIS)

    Schneider, Christopher; Newhauser, Wayne; Farah, Jad

    2015-01-01

    Exposure to stray neutrons increases the risk of second cancer development after proton therapy. Previously reported analytical models of this exposure were difficult to configure and had not been investigated below 100 MeV proton energy. The purposes of this study were to test an analytical model of neutron equivalent dose per therapeutic absorbed dose (H/D) at 75 MeV and to improve the model by reducing the number of configuration parameters and making it continuous in proton energy from 100 to 250 MeV. To develop the analytical model, we used previously published H/D values in water from Monte Carlo simulations of a general-purpose beamline for proton energies from 100 to 250 MeV. We also configured and tested the model on in-air neutron equivalent doses measured for a 75 MeV ocular beamline. Predicted H/D values from the analytical model and Monte Carlo agreed well from 100 to 250 MeV (10% average difference). Predicted H/D values from the analytical model also agreed well with measurements at 75 MeV (15% average difference). The results indicate that analytical models can give fast, reliable calculations of neutron exposure after proton therapy. This ability is absent in treatment planning systems but vital to second cancer risk estimation

  12. An Analytical Model of Leakage Neutron Equivalent Dose for Passively-Scattered Proton Radiotherapy and Validation with Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, Christopher; Newhauser, Wayne, E-mail: newhauser@lsu.edu [Department of Physics and Astronomy, Louisiana State University and Agricultural and Mechanical College, 202 Nicholson Hall, Baton Rouge, LA 70803 (United States); Mary Bird Perkins Cancer Center, 4950 Essen Lane, Baton Rouge, LA 70809 (United States); Farah, Jad [Institut de Radioprotection et de Sûreté Nucléaire, Service de Dosimétrie Externe, BP-17, 92262 Fontenay-aux-Roses (France)

    2015-05-18

    Exposure to stray neutrons increases the risk of second cancer development after proton therapy. Previously reported analytical models of this exposure were difficult to configure and had not been investigated below 100 MeV proton energy. The purposes of this study were to test an analytical model of neutron equivalent dose per therapeutic absorbed dose (H/D) at 75 MeV and to improve the model by reducing the number of configuration parameters and making it continuous in proton energy from 100 to 250 MeV. To develop the analytical model, we used previously published H/D values in water from Monte Carlo simulations of a general-purpose beamline for proton energies from 100 to 250 MeV. We also configured and tested the model on in-air neutron equivalent doses measured for a 75 MeV ocular beamline. Predicted H/D values from the analytical model and Monte Carlo agreed well from 100 to 250 MeV (10% average difference). Predicted H/D values from the analytical model also agreed well with measurements at 75 MeV (15% average difference). The results indicate that analytical models can give fast, reliable calculations of neutron exposure after proton therapy. This ability is absent in treatment planning systems but vital to second cancer risk estimation.

  13. Calculation of committed dose equivalent from intake of tritiated water

    International Nuclear Information System (INIS)

    Law, D.V.

    1978-08-01

    A new computerized method of calculating the committed dose equivalent from the intake of tritiated water at Harwell is described in this report. The computer program has been designed to deal with a variety of intake patterns and urine sampling schemes, as well as to produce committed dose equivalents corresponding to any periods for which individual monitoring for external radiation is undertaken. Details of retrospective doses are added semi-automatically to the Radiation Dose Records and committed dose equivalents are retained on a separate file. (author)

  14. Feedback equivalence of convolutional codes over finite rings

    Directory of Open Access Journals (Sweden)

    DeCastro-García Noemí

    2017-12-01

    Full Text Available The approach to convolutional codes from the linear systems point of view provides us with effective tools in order to construct convolutional codes with adequate properties that let us use them in many applications. In this work, we have generalized feedback equivalence between families of convolutional codes and linear systems over certain rings, and we show that every locally Brunovsky linear system may be considered as a representation of a code under feedback convolutional equivalence.

  15. Equivalent model construction for a non-linear dynamic system based on an element-wise stiffness evaluation procedure and reduced analysis of the equivalent system

    Science.gov (United States)

    Kim, Euiyoung; Cho, Maenghyo

    2017-11-01

    In most non-linear analyses, the construction of a system matrix uses a large amount of computation time, comparable to the computation time required by the solving process. If the process for computing non-linear internal force matrices is substituted with an effective equivalent model that enables the bypass of numerical integrations and assembly processes used in matrix construction, efficiency can be greatly enhanced. A stiffness evaluation procedure (STEP) establishes non-linear internal force models using polynomial formulations of displacements. To efficiently identify an equivalent model, the method has evolved such that it is based on a reduced-order system. The reduction process, however, makes the equivalent model difficult to parameterize, which significantly affects the efficiency of the optimization process. In this paper, therefore, a new STEP, E-STEP, is proposed. Based on the element-wise nature of the finite element model, the stiffness evaluation is carried out element-by-element in the full domain. Since the unit of computation for the stiffness evaluation is restricted by element size, and since the computation is independent, the equivalent model can be constructed efficiently in parallel, even in the full domain. Due to the element-wise nature of the construction procedure, the equivalent E-STEP model is easily characterized by design parameters. Various reduced-order modeling techniques can be applied to the equivalent system in a manner similar to how they are applied in the original system. The reduced-order model based on E-STEP is successfully demonstrated for the dynamic analyses of non-linear structural finite element systems under varying design parameters.

  16. Reduction of Linear Functional Systems using Fuhrmann's Equivalence

    Directory of Open Access Journals (Sweden)

    Mohamed S. Boudellioua

    2016-11-01

    Full Text Available Functional systems arise in the treatment of systems of partial differential equations, delay-differential equations, multidimensional equations, etc. The problem of reducing a linear functional system to a system containing fewer equations and unknowns was first studied by Serre. Finding an equivalent presentation of a linear functional system containing fewer equations and fewer unknowns can generally simplify both the study of the structural properties of the linear functional system and of different numerical analysis issues, and it can sometimes help in solving the linear functional system. In this paper, Fuhrmann's equivalence is used to present a constructive result on the reduction of under-determined linear functional systems to a single equation involving a single unknown. This equivalence transformation has been studied by a number of authors and has been shown to play an important role in the theory of linear functional systems.

  17. Principle of natural and artificial radioactive series equivalency

    International Nuclear Information System (INIS)

    Vasilyeva, A.N.; Starkov, O.V.

    2001-01-01

    In the present paper one approach used under development of radioactive waste management conception is under consideration. This approach is based on the principle of natural and artificial radioactive series radiotoxic equivalency. The radioactivity of natural and artificial radioactive series has been calculated for 10 9 - years period. The toxicity evaluation for natural and artificial series has also been made. The correlation between natural radioactive series and their predecessors - actinides produced in thermal and fast reactors - has been considered. It has been shown that systematized reactor series data had great scientific significance and the principle of differential calculation of radiotoxicity was necessary to realize long-lived radioactive waste and uranium and thorium ore radiotoxicity equivalency conception. The calculations show that the execution of equivalency principle is possible for uranium series (4n+2, 4n+1). It is a problem for thorium. series. This principle is impracticable for neptunium series. (author)

  18. Ecological Equivalence Assessment Methods: What Trade-Offs between Operationality, Scientific Basis and Comprehensiveness?

    Science.gov (United States)

    Bezombes, Lucie; Gaucherand, Stéphanie; Kerbiriou, Christian; Reinert, Marie-Eve; Spiegelberger, Thomas

    2017-08-01

    In many countries, biodiversity compensation is required to counterbalance negative impacts of development projects on biodiversity by carrying out ecological measures, called offset when the goal is to reach "no net loss" of biodiversity. One main issue is to ensure that offset gains are equivalent to impact-related losses. Ecological equivalence is assessed with ecological equivalence assessment methods taking into account a range of key considerations that we summarized as ecological, spatial, temporal, and uncertainty. When equivalence assessment methods take into account all considerations, we call them "comprehensive". Equivalence assessment methods should also aim to be science-based and operational, which is challenging. Many equivalence assessment methods have been developed worldwide but none is fully satisfying. In the present study, we examine 13 equivalence assessment methods in order to identify (i) their general structure and (ii) the synergies and trade-offs between equivalence assessment methods characteristics related to operationality, scientific-basis and comprehensiveness (called "challenges" in his paper). We evaluate each equivalence assessment methods on the basis of 12 criteria describing the level of achievement of each challenge. We observe that all equivalence assessment methods share a general structure, with possible improvements in the choice of target biodiversity, the indicators used, the integration of landscape context and the multipliers reflecting time lags and uncertainties. We show that no equivalence assessment methods combines all challenges perfectly. There are trade-offs between and within the challenges: operationality tends to be favored while scientific basis are integrated heterogeneously in equivalence assessment methods development. One way of improving the challenges combination would be the use of offset dedicated data-bases providing scientific feedbacks on previous offset measures.

  19. Validity of the Aluminum Equivalent Approximation in Space Radiation Shielding

    Science.gov (United States)

    Badavi, Francis F.; Adams, Daniel O.; Wilson, John W.

    2009-01-01

    The origin of the aluminum equivalent shield approximation in space radiation analysis can be traced back to its roots in the early years of the NASA space programs (Mercury, Gemini and Apollo) wherein the primary radiobiological concern was the intense sources of ionizing radiation causing short term effects which was thought to jeopardize the safety of the crew and hence the mission. Herein, it is shown that the aluminum equivalent shield approximation, although reasonably well suited for that time period and to the application for which it was developed, is of questionable usefulness to the radiobiological concerns of routine space operations of the 21 st century which will include long stays onboard the International Space Station (ISS) and perhaps the moon. This is especially true for a risk based protection system, as appears imminent for deep space exploration where the long-term effects of Galactic Cosmic Ray (GCR) exposure is of primary concern. The present analysis demonstrates that sufficiently large errors in the interior particle environment of a spacecraft result from the use of the aluminum equivalent approximation, and such approximations should be avoided in future astronaut risk estimates. In this study, the aluminum equivalent approximation is evaluated as a means for estimating the particle environment within a spacecraft structure induced by the GCR radiation field. For comparison, the two extremes of the GCR environment, the 1977 solar minimum and the 2001 solar maximum, are considered. These environments are coupled to the Langley Research Center (LaRC) deterministic ionized particle transport code High charge (Z) and Energy TRaNsport (HZETRN), which propagates the GCR spectra for elements with charges (Z) in the range I aluminum equivalent approximation for a good polymeric shield material such as genetic polyethylene (PE). The shield thickness is represented by a 25 g/cm spherical shell. Although one could imagine the progression to greater

  20. ASCERTAINMENT OF THE EQUIVALENT CIRCUIT PARAMETERS OF THE ASYNCHRONOUS MACHINE

    Directory of Open Access Journals (Sweden)

    V. S. Safaryan

    2015-01-01

    Full Text Available The article considers experimental and analytical determination of the asynchronous machine equivalent-circuit parameters with application of the reference data. Transient processes investigation of the asynchronous machines necessitates the equivalent circuit parameters (resistance impedance, inductances and coefficient of the stator-rotor contours mutual inductance that help form the transitory-process mathematical simulation model. The reference books do not provide those parameters; they instead give the rated ones (active power, voltage, slide, coefficient of performance and capacity coefficient as well as the ratio of starting and nominal currents and torques. The noted studies on the asynchronous machine equivalent-circuits parametrization fail to solve the problems ad finem or solve them with admissions. The paper presents experimental and analytical determinations of the asynchronous machine equivalent-circuit parameters: the experimental one based on the results of two measurements and the analytical one where the problem boils down to solving a system of nonlineal algebraic equations. The authors investigate the equivalent asynchronous machine input-resistance properties and adduce the dependence curvatures of the input-resistances on the slide. They present a symbolic model for analytical parameterization of the asynchronous machine equivalent-circuit that represents a system of nonlineal equations and requires one of the rotor-parameters arbitrary assignment. The article demonstrates that for the asynchronous machine equivalent-circuit experimental parameterization the measures are to be conducted of the stator-circuit voltage, current and active power with two different slides and arbitrary assignment of one of the rotor parameters. The paper substantiates the fact that additional measurement does not discard the rotor-parameter choice arbitrariness. The authors establish that in motoring mode there is a critical slide by which the

  1. Development of solid water-equivalent radioactive certified reference materials

    International Nuclear Information System (INIS)

    Finke, E.; Greupner, H.; Groche, K.; Rittwag, R.; Geske, G.

    1991-01-01

    This paper presents a brief description of the development of solid water-equivalent beta volume radioactive certified reference materials. These certified reference materials were prepared for the beta fission nuclides 90 Sr/ 90 Y, 137 Cs, 147 Pm and 204 Tl. Comparative measurements of liquid and solid water-equivalent beta volume radioactive certified reference materials are discussed. (author)

  2. Tracer Equivalent Latitude: A Diagnostic Tool for Isentropic Transport Studies.

    Science.gov (United States)

    Allen, Douglas R.; Nakamura, Noboru

    2003-01-01

    Area equivalent latitude based on potential vorticity (PV) is a widely used diagnostic for isentropic transport in the stratosphere and upper troposphere. Here, an alternate method for calculating equivalent latitude is explored, namely, a numerical synthesis of a PV-like tracer from a long-term integration of the advection-diffusion equation on isentropic surfaces. It is found that the tracer equivalent latitude (TrEL) behaves much like the traditional PV equivalent latitude (PVEL) despite the simplified governing physics; this is evidenced by examining the kinematics of the Arctic lower stratospheric vortex. Yet in some cases TrEL performs markedly better as a coordinate for long-lived trace species such as ozone. These instances include analysis of lower stratospheric ozone during the Stratospheric Aerosol and Gas Experiment (SAGE) III Ozone Loss and Validation Experiment (SOLVE) campaign and three-dimensional reconstruction of total column ozone during November-December 1999 from fitted ozone-equivalent latitude relationship. It is argued that the improvement is due to the tracer being free from the diagnostic errors and certain diabatic processes that affect PV. The sensitivity of TrEL to spatial and temporal resolution, advection scheme, and driving winds is also examined.

  3. Global equivalent magnetization of the oceanic lithosphere

    Science.gov (United States)

    Dyment, J.; Choi, Y.; Hamoudi, M.; Lesur, V.; Thebault, E.

    2015-11-01

    As a by-product of the construction of a new World Digital Magnetic Anomaly Map over oceanic areas, we use an original approach based on the global forward modeling of seafloor spreading magnetic anomalies and their comparison to the available marine magnetic data to derive the first map of the equivalent magnetization over the World's ocean. This map reveals consistent patterns related to the age of the oceanic lithosphere, the spreading rate at which it was formed, and the presence of mantle thermal anomalies which affects seafloor spreading and the resulting lithosphere. As for the age, the equivalent magnetization decreases significantly during the first 10-15 Myr after its formation, probably due to the alteration of crustal magnetic minerals under pervasive hydrothermal alteration, then increases regularly between 20 and 70 Ma, reflecting variations in the field strength or source effects such as the acquisition of a secondary magnetization. As for the spreading rate, the equivalent magnetization is twice as strong in areas formed at fast rate than in those formed at slow rate, with a threshold at ∼40 km/Myr, in agreement with an independent global analysis of the amplitude of Anomaly 25. This result, combined with those from the study of the anomalous skewness of marine magnetic anomalies, allows building a unified model for the magnetic structure of normal oceanic lithosphere as a function of spreading rate. Finally, specific areas affected by thermal mantle anomalies at the time of their formation exhibit peculiar equivalent magnetization signatures, such as the cold Australian-Antarctic Discordance, marked by a lower magnetization, and several hotspots, marked by a high magnetization.

  4. Equivalent model and power flow model for electric railway traction network

    Science.gov (United States)

    Wang, Feng

    2018-05-01

    An equivalent model of the Cable Traction Network (CTN) considering the distributed capacitance effect of the cable system is proposed. The model can be divided into 110kV side and 27.5kV side two kinds. The 110kV side equivalent model can be used to calculate the power supply capacity of the CTN. The 27.5kV side equivalent model can be used to solve the voltage of the catenary. Based on the equivalent simplified model of CTN, the power flow model of CTN which involves the reactive power compensation coefficient and the interaction of voltage and current, is derived.

  5. Equivalence of Lagrangian and Hamiltonian BRST quantizations

    International Nuclear Information System (INIS)

    Grigoryan, G.V.; Grigoryan, R.P.; Tyutin, I.V.

    1992-01-01

    Two approaches to the quantization of gauge theories using BRST symmetry are widely used nowadays: the Lagrangian quantization, developed in (BV-quantization) and Hamiltonian quantization, formulated in (BFV-quantization). For all known examples of field theory (Yang-Mills theory, gravitation etc.) both schemes give equivalent results. However the equivalence of these approaches in general wasn't proved. The main obstacle in comparing of these formulations consists in the fact, that in Hamiltonian approach the number of ghost fields is equal to the number of all first-class constraints, while in the Lagrangian approach the number of ghosts is equal to the number of independent gauge symmetries, which is equal to the number of primary first-class constraints only. This paper is devoted to the proof of the equivalence of Lagrangian and Hamiltonian quantizations for the systems with first-class constraints only. This is achieved by a choice of special gauge in the Hamiltonian approach. It's shown, that after integration over redundant variables on the functional integral we come to effective action which is constructed according to rules for construction of the effective action in Lagrangian quantization scheme

  6. Two-group Current-equivalent Parameters for Control Rod Cells. Autocode Programme CRCC

    Energy Technology Data Exchange (ETDEWEB)

    Norinder, O; Nyman, K

    1962-06-15

    In two-group neutron diffusion calculations there is mostly necessary to describe the influence of control rods by equivalent homogeneous two-group parameters in regions about the control rods. The problem is solved for a control rod in a medium characterized by two-group parameters. The property of fast and thermal neutr. on current equivalence is selected to obtain equivalent two-group parameters for a homogeneous cell with the same radius as the control rod cell. For the parameters determined one obtains the same fast and thermal neutron current into the rod cell and the equivalent cell independent of the fast and thermal flux amplitudes on the cell boundaries. The equivalent parameters are obtained as a solution of a system of transcendental equations. A Ferranti Mercury Autocode performing the solution is described. Calculated equivalent parameters for control rods in a heavy water lattice are given for some representative cases.

  7. Committed dose equivalent in the practice of radiological protection

    International Nuclear Information System (INIS)

    Nenot, J.C.; Piechowski, J.

    1985-01-01

    In the case of internal exposure, the dose is not received at the moment of exposure, as happens with external exposure, since the incorporated radionuclide irradiates the various organs and tissues during the time it is present in the body. By definition, the committed dose equivalent corresponds to the received dose integrated over 50 years from the date of intake. In order to calculate it, one has to know the intake activity and the value of the committed dose equivalent per unit of intake activity. The uncertainties of the first parameter are such that the committed dose equivalent can only be regarded as an order of magnitude and not as a very accurate quantity. The use of it is justified, however, for, like the dose equivalent for external exposure, it expresses the risk of stochastic effects for the individual concerned since these effects, should they appear, would do so only after a latent period which is generally longer than the dose integration time. Moreover, the use of the committed dose equivalent offers certain advantages for dosimetric management, especially when it is simplified. A practical problem which may arise is that the annual dose limit is apparently exceeded by virtue of the fact that one is taking account, in the first year, of doses which will actually be received only in the following years. These problems are rare enough in practice to be dealt with individually in each case. (author)

  8. interpratation: of equivalences and cultural untranslatability

    African Journals Online (AJOL)

    jgmweri

    translatability in cultural diversity in terms equivalences such as –Vocabulary or lexical ..... A KSL interpreter who does not understand this English idiom may literally interpret it .... Nida, E.A. (1958) Analysis of meaning and dictionary making.

  9. Thevenin Equivalent Method for Dynamic Contingency Assessment

    DEFF Research Database (Denmark)

    Møller, Jakob Glarbo; Jóhannsson, Hjörtur; Østergaard, Jacob

    2015-01-01

    A method that exploits Thevenin equivalent representation for obtaining post-contingency steady-state nodal voltages is integrated with a method of detecting post-contingency aperiodic small-signal instability. The task of integrating stability assessment with contingency assessment is challenged...... by the cases of unstable post-contingency conditions. For unstable postcontingency conditions there exists no credible steady-state which can be used for basis of a stability assessment. This paper demonstrates how Thevenin Equivalent methods can be applied in algebraic representation of such bifurcation...... points which may be used in assessment of post-contingency aperiodic small-signal stability. The assessment method is introduced with a numeric example....

  10. Culturemes and Non-Equivalent Lexis in Dictionaries

    Directory of Open Access Journals (Sweden)

    Maciej Paweł Jaskot

    2015-12-01

    Full Text Available Culturemes and Non-Equivalent Lexis in Dictionaries The article raises the question of the need to improve the structural diversity and operational capabilities of the modern dictionary (bi- or multilingual to avoid lacunes in the transmission of culturemes and non-equivalent words into another language. Without it the dictionary is incomplete and languages are unequal. The article deals with various options of asymmetry reflection of the culturemes in the context of social and ethno-psychic reality of a native-speaking community. The specifics of lexicographical transmission is observed in order to emphasize the need of further investigation of the linguistic map of the world.

  11. 10 CFR Appendix to Part 474 - Sample Petroleum-Equivalent Fuel Economy Calculations

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Sample Petroleum-Equivalent Fuel Economy Calculations..., DEVELOPMENT, AND DEMONSTRATION PROGRAM; PETROLEUM-EQUIVALENT FUEL ECONOMY CALCULATION Pt. 474, App. Appendix to Part 474—Sample Petroleum-Equivalent Fuel Economy Calculations Example 1: An electric vehicle is...

  12. An Algebraic Approach to Knowledge Bases Informational Equivalence

    OpenAIRE

    Plotkin, B.; Plotkin, T.

    2003-01-01

    In this paper we study the notion of knowledge from the positions of universal algebra and algebraic logic. We consider first order knowledge which is based on first order logic. We define categories of knowledge and knowledge bases. These notions are defined for the fixed subject of knowledge. The key notion of informational equivalence of two knowledge bases is introduced. We use the idea of equivalence of categories in this definition. We prove that for finite models there is a clear way t...

  13. Generating carbyne equivalents with photoredox catalysis

    Science.gov (United States)

    Wang, Zhaofeng; Herraiz, Ana G.; Del Hoyo, Ana M.; Suero, Marcos G.

    2018-02-01

    Carbon has the unique ability to bind four atoms and form stable tetravalent structures that are prevalent in nature. The lack of one or two valences leads to a set of species—carbocations, carbanions, radicals and carbenes—that is fundamental to our understanding of chemical reactivity. In contrast, the carbyne—a monovalent carbon with three non-bonded electrons—is a relatively unexplored reactive intermediate; the design of reactions involving a carbyne is limited by challenges associated with controlling its extreme reactivity and the lack of efficient sources. Given the innate ability of carbynes to form three new covalent bonds sequentially, we anticipated that a catalytic method of generating carbynes or related stabilized species would allow what we term an ‘assembly point’ disconnection approach for the construction of chiral centres. Here we describe a catalytic strategy that generates diazomethyl radicals as direct equivalents of carbyne species using visible-light photoredox catalysis. The ability of these carbyne equivalents to induce site-selective carbon-hydrogen bond cleavage in aromatic rings enables a useful diazomethylation reaction, which underpins sequencing control for the late-stage assembly-point functionalization of medically relevant agents. Our strategy provides an efficient route to libraries of potentially bioactive molecules through the installation of tailored chiral centres at carbon-hydrogen bonds, while complementing current translational late-stage functionalization processes. Furthermore, we exploit the dual radical and carbene character of the generated carbyne equivalent in the direct transformation of abundant chemical feedstocks into valuable chiral molecules.

  14. On equivalent resistance of electrical circuits

    Science.gov (United States)

    Kagan, Mikhail

    2015-01-01

    While the standard (introductory physics) way of computing the equivalent resistance of nontrivial electrical circuits is based on Kirchhoff's rules, there is a mathematically and conceptually simpler approach, called the method of nodal potentials, whose basic variables are the values of the electric potential at the circuit's nodes. In this paper, we review the method of nodal potentials and illustrate it using the Wheatstone bridge as an example. We then derive a closed-form expression for the equivalent resistance of a generic circuit, which we apply to a few sample circuits. The result unveils a curious interplay between electrical circuits, matrix algebra, and graph theory and its applications to computer science. The paper is written at a level accessible by undergraduate students who are familiar with matrix arithmetic. Additional proofs and technical details are provided in appendices.

  15. Development of solid water-equivalent radioactive certified reference materials

    Energy Technology Data Exchange (ETDEWEB)

    Finke, E.; Greupner, H.; Groche, K.; Rittwag, R. (Office for Standardization, Metrology and Quality Control (ASMW), Berlin (Germany, F.R.)); Geske, G. (Jena Univ. (Germany, F.R.))

    1991-01-01

    This paper presents a brief description of the development of solid water-equivalent beta volume radioactive certified reference materials. These certified reference materials were prepared for the beta fission nuclides {sup 90}Sr/{sup 90}Y, {sup 137}Cs, {sup 147}Pm and {sup 204}Tl. Comparative measurements of liquid and solid water-equivalent beta volume radioactive certified reference materials are discussed. (author).

  16. Study on the neutron dosimetric characteristics of Tissue Equivalent Proportional Counter

    Energy Technology Data Exchange (ETDEWEB)

    Nunomiya, T.; Kim, E.; Kurosawa, T.; Taniguchi, S.; Nakamura, T. [Tohoku Univ., Sendai (Japan). Cyclotron and Radioisotope Center; Tsujimura, N.; Momose, T.; Shinohara, K. [Japan Nuclear Cycle Development Inst., Environment and Safety Division, Tokai Works, Tokai, Ibaraki (Japan)

    1999-03-01

    The neutron dosimetric characteristics of TEPC (Tissue Equivalent Proportional Counter) has been investigated under a cooperative study between Tohoku University and JNC since 1997. This TEPC is a spherical, large volume, single-wire proportional counter (the model LETSW-5, manufactured by Far West Technology, Inc.) and filled with a tissue equivalent gas in a spherical detector of the A-150 tissue equivalent plastic. The TEPC can measure the spectra of absorbed dose in LET and easily estimate the tissue equivalent dose to neutron. This report summarizes the dosimetric characteristics of TEPC to the monoenergetic neutrons with energy from 8 keV to 15 MeV. It is found that TEPC can estimate the ambient dose equivalent, H*(10), with an accuracy from 0.9 to 2 to the neutron above 0.25 MeV and TEPC has a good counting efficiency enough to measure neutron doses with low dose rate at the stray neutron fields. (author)

  17. The Goldstone equivalence theorem and AdS/CFT

    Energy Technology Data Exchange (ETDEWEB)

    Anand, Nikhil; Cantrell, Sean [Department of Physics & Astronomy, Johns Hopkins University,Baltimore, MD 21218 (United States)

    2015-08-03

    The Goldstone equivalence theorem allows one to relate scattering amplitudes of massive gauge fields to those of scalar fields in the limit of large scattering energies. We generalize this theorem under the framework of the AdS/CFT correspondence. First, we obtain an expression of the equivalence theorem in terms of correlation functions of creation and annihilation operators by using an AdS wave function approach to the AdS/CFT dictionary. It is shown that the divergence of the non-conserved conformal current dual to the bulk gauge field is approximately primary when computing correlators for theories in which the masses of all the exchanged particles are sufficiently large. The results are then generalized to higher spin fields. We then go on to generalize the theorem using conformal blocks in two and four-dimensional CFTs. We show that when the scaling dimensions of the exchanged operators are large compared to both their spins and the dimension of the current, the conformal blocks satisfy an equivalence theorem.

  18. On the homotopy equivalence of simple AI-algebras

    International Nuclear Information System (INIS)

    Aristov, O Yu

    1999-01-01

    Let A and B be simple unital AI-algebras (an AI-algebra is an inductive limit of C*-algebras of the form BigOplus i k C([0,1],M N i ). It is proved that two arbitrary unital homomorphisms from A into B such that the corresponding maps K 0 A→K 0 B coincide are homotopic. Necessary and sufficient conditions on the Elliott invariant for A and B to be homotopy equivalent are indicated. Moreover, two algebras in the above class having the same K-theory but not homotopy equivalent are constructed. A theorem on the homotopy of approximately unitarily equivalent homomorphisms between AI-algebras is used in the proof, which is deduced in its turn from a generalization to the case of AI-algebras of a theorem of Manuilov stating that a unitary matrix almost commuting with a self-adjoint matrix h can be joined to 1 by a continuous path consisting of unitary matrices almost commuting with h

  19. Equivalence Testing as a Tool for Fatigue Risk Management in Aviation.

    Science.gov (United States)

    Wu, Lora J; Gander, Philippa H; van den Berg, Margo; Signal, T Leigh

    2018-04-01

    Many civilian aviation regulators favor evidence-based strategies that go beyond hours-of-service approaches for managing fatigue risk. Several countries now allow operations to be flown outside of flight and duty hour limitations, provided airlines demonstrate an alternative method of compliance that yields safety levels "at least equivalent to" the prescriptive regulations. Here we discuss equivalence testing in occupational fatigue risk management. We present suggested ratios/margins of practical equivalence when comparing operations inside and outside of prescriptive regulations for two common aviation safety performance indicators: total in-flight sleep duration and psychomotor vigilance task reaction speed. Suggested levels of practical equivalence, based on expertise coupled with evidence from field and laboratory studies, are ≤ 30 min in-flight sleep and ± 15% of reference response speed. Equivalence testing is illustrated in analyses of a within-subjects field study during an out-and-back long-range trip. During both sectors of their trip, 41 pilots were monitored via actigraphy, sleep diary, and top of descent psychomotor vigilance task. Pilots were assigned to take rest breaks in a standard lie-flat bunk on one sector and in a bunk tapered 9 from hip to foot on the other sector. Total in-flight sleep duration (134 ± 53 vs. 135 ± 55 min) and mean reaction speed at top of descent (3.94 ± 0.58 vs. 3.77 ± 0.58) were equivalent after rest in the full vs. tapered bunk. Equivalence testing is a complimentary statistical approach to difference testing when comparing levels of fatigue and performance in occupational settings and can be applied in transportation policy decision making.Wu LJ, Gander PH, van den Berg M, Signal TL. Equivalence testing as a tool for fatigue risk management in aviation. Aerosp Med Hum Perform. 2018; 89(4):383-388.

  20. An investigation into the equivalent parameter method for homogeneous transport equivalent parameters for use in fast reactor control assemblies

    International Nuclear Information System (INIS)

    Tullett, J.D.

    1990-01-01

    P Benoist has developed a method for calculating cross-sections for Fast Reactor control rods and their followers described by a single homogenised region (the Equivalent Parameter Method). When used in a diffusion theory calculation, these equivalent cross-sections should give the same rod worth as one would obtain from a transport theory calculation with a heterogeneous description of the control rod and the follower. In this report, Benoist's theory is described, and a comprehensive set of tests is presented. These tests show that the method gives very good results over a range of geometries and control rod positions for a model fast reactor core. (author)

  1. Equivalence of rational representations of behaviors

    NARCIS (Netherlands)

    Gottimukkala, Sasanka; Fiaz, Shaik; Trentelman, H.L.

    This article deals with the equivalence of representations of behaviors of linear differential systems. In general, the behavior of a given linear differential system has many different representations. In this paper we restrict ourselves to kernel and image representations. Two kernel

  2. Inductive Reasoning in Zambia, Turkey, and the Netherlands Establishing Cross-Cultural Equivalence.

    Science.gov (United States)

    van de Vijver, Fons J. R.

    2002-01-01

    Administered tasks of inductive reasoning to 704 Zambian, 877 Turkish, and 632 Dutch students from the highest 2 grades of primary and the lowest 2 grades of secondary school. Results show strong evidence for structural equivalence and partial evidence for measurement unit equivalence, but did not support full score equivalence. (SLD)

  3. Annual average equivalent dose of workers form health area

    International Nuclear Information System (INIS)

    Daltro, T.F.L.; Campos, L.L.

    1992-01-01

    The data of personnel monitoring during 1985 and 1991 of personnel that work in health area were studied, obtaining a general overview of the value change of annual average equivalent dose. Two different aspects were presented: the analysis of annual average equivalent dose in the different sectors of a hospital and the comparison of these doses in the same sectors in different hospitals. (C.G.C.)

  4. The Equivalence of Grayson and Friedlander-Suslin Spectral Sequences

    OpenAIRE

    Podkopaev, Oleg

    2013-01-01

    This thesis establishes the equivalence of Grayson and Friedlander-Suslin spectral sequences, that was previously only known for the respective E_2-terms. We develop the necessary techniques regarding K_0-presheaves of spectra, building on the work of M. Walker and construct certain filtrations on the K-theory presheaf of spectra that we use as intermediate steps in obtaining the equivalence of the filtrations.

  5. The Logic of Equivalence in Academic Discourse?

    DEFF Research Database (Denmark)

    Madsen, Dorte

    2017-01-01

    of discourse to distinguish between the scientific field, where interrelationships among academic disciplines are taken as an object of research, and the widespread uses of ‘interdisciplinary’ and ‘interdisciplinarity’ in academic discourse more generally, typically for legitimation purposes. The assumption......-discourses meet. It is suggested that the logics of signification, and the tension between difference and equivalence, may be important tools for theorizing this borderland. It is argued that whereas the logic of equivalence and the production of empty signifiers appears to be of marginal interest...... to the scientific field, the logic of difference as a more complex articulation of elements, seems to be more in line with the ideals of academic discourse....

  6. Theory of Covariance Equivalent ARMAV Models of Civil Engineering Structures

    DEFF Research Database (Denmark)

    Andersen, P.; Brincker, Rune; Kirkegaard, Poul Henning

    1996-01-01

    In this paper the theoretical background for using covariance equivalent ARMAV models in modal analysis is discussed. It is shown how to obtain a covariance equivalent ARMA model for a univariate linear second order continous-time system excited by Gaussian white noise. This result is generalized...

  7. Theory of Covariance Equivalent ARMAV Models of Civil Engineering Structures

    DEFF Research Database (Denmark)

    Andersen, P.; Brincker, Rune; Kirkegaard, Poul Henning

    In this paper the theoretical background for using covariance equivalent ARMAV models in modal analysis is discussed. It is shown how to obtain a covariance equivalent ARMA model for a univariate linear second order continuous-time system excited by Gaussian white noise. This result is generalize...

  8. On Behavioral Equivalence of Rational Representations

    NARCIS (Netherlands)

    Trentelman, Harry L.; Willems, JC; Hara, S; Ohta, Y; Fujioka, H

    2010-01-01

    This article deals with the equivalence of representations of behaviors of linear differential systems In general. the behavior of a given linear differential system has many different representations. In this paper we restrict ourselves to kernel representations and image representations Two kernel

  9. The Equivalence between -Stabilities of The Krasnoselskij and The Mann Iterations

    Directory of Open Access Journals (Sweden)

    Şoltuz Ştefan M

    2007-01-01

    Full Text Available We prove the equivalence between the -stabilities of the Krasnoselskij and the Mann iterations; a consequence is the equivalence with the -stability of the Picard-Banach iteration.

  10. Equivalent Circuit Modeling of the Dielectric Loaded Microwave Biosensor

    Directory of Open Access Journals (Sweden)

    M. T. Jilani

    2014-12-01

    Full Text Available This article describes the modeling of biological tissues at microwave frequency using equivalent lumped elements. A microwave biosensor based on microstrip ring resonator (MRR, that has been utilized previously for meat quality evaluation is used for this purpose. For the first time, the ring-resonator loaded with the lossy and high permittivity dielectric material, such as; biological tissue, in a partial overlay configuration is analyzed. The equivalent circuit modeling of the structure is then performed to identify the effect of overlay thickness on the resonance frequency. Finally, the relationship of an overlay thickness with the corresponding RC values of the meat equivalent circuit is established. Simulated, calculated and measured results are then compared for validation. Results are well agreed while the observed discrepancy is in acceptable limit.

  11. Dose equivalent response of personal neutron dosemeters as a function of angle

    International Nuclear Information System (INIS)

    Tanner, J.E.; McDonald, J.C.; Stewart, R.D.; Wernli, C.

    1997-01-01

    The measured and calculated dose equivalent response as a function of angle has been examined for an albedo-type thermoluminescence dosemeter (TLD) that was exposed to unmoderated and D 2 O-moderated 252 Cf neutron sources while mounted on a 40 x 40 15 cm 3 polymethylmethacrylate phantom. The dosemeter used in this study is similar to many neutron personal dosemeters currently in use. The detailed construction of the dosemeter was modelled, and the dose equivalent response was calculated, using the MCNP code. Good agreement was found between the measured and calculated values of the relative dose equivalent angular response for the TLD albedo dosemeter. The relative dose equivalent angular response was also compared with the values of directional and personal dose equivalent as a function of angle published by Siebert and Schuhmacher. (author)

  12. Energy conservation and the principle of equivalence

    International Nuclear Information System (INIS)

    Haugan, M.P.

    1979-01-01

    If the equivalence principle is violated, then observers performing local experiments can detect effects due to their position in an external gravitational environment (preferred-location effects) or can detect effects due to their velocity through some preferred frame (preferred frame effects). We show that the principle of energy conservation implies a quantitative connection between such effects and structure-dependence of the gravitational acceleration of test bodies (violation of the Weak Equivalence Principle). We analyze this connection within a general theoretical framework that encompasses both non-gravitational local experiments and test bodies as well as gravitational experiments and test bodies, and we use it to discuss specific experimental tests of the equivalence principle, including non-gravitational tests such as gravitational redshift experiments, Eoetvoes experiments, the Hughes-Drever experiment, and the Turner-Hill experiment, and gravitational tests such as the lunar-laser-ranging ''Eoetvoes'' experiment, and measurements of anisotropies and variations in the gravitational constant. This framework is illustrated by analyses within two theoretical formalisms for studying gravitational theories: the PPN formalism, which deals with the motion of gravitating bodies within metric theories of gravity, and the THepsilonμ formalism that deals with the motion of charged particles within all metric theories and a broad class of non-metric theories of gravity

  13. The Public Market Equivalent and Private Equity Performance

    DEFF Research Database (Denmark)

    Sørensen, Morten; Jagannathan, Ravi

    2015-01-01

    The authors show that the public market equivalent approach is equivalent to assessing the performance of private equity (PE) investments using Rubinstein’s dynamic version of the CAPM. They developed two insights: (1) one need not compute betas of PE investments, and any changes in PE cash flow...... betas due to changes in financial leverage, operating leverage, or the nature of the business are automatically taken into account; (2) the public market index used in evaluations should be the one that best approximates the wealth portfolio of the investor considering the PE investment opportunity....

  14. 10 CFR 835.203 - Combining internal and external equivalent doses.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Combining internal and external equivalent doses. 835.203 Section 835.203 Energy DEPARTMENT OF ENERGY OCCUPATIONAL RADIATION PROTECTION Standards for Internal and External Exposure § 835.203 Combining internal and external equivalent doses. (a) The total effective dose...

  15. Equivalency relations for mixtures of nuclides in shipping casks 9972-9975

    International Nuclear Information System (INIS)

    Niemer, K.A.; Frost, R.L.; Williamson, T.G.

    1994-01-01

    Equivalence relations required to determine mass limits for mixtures of nuclides for the Safety Analysis Report for Packaging (SARP) of the Savannah River Site 9972, 9973, 9974, and 9975 shipping casks were calculated. The systems analyzed included aqueous spheres, homogeneous metal spheres, and metal ball-and-shell configurations, all surrounded by an effectively infinite stainless steel or water reflector. Comparison of the equivalence calculations with the rule-of-fractions showed conservative agreement for aqueous solutions, both conservative and non-conservative agreement for the metal homogenous sphere systems, and non-conservative agreement for the majority of metal ball-and-shell systems. Equivalence factors for the aqueous solutions and homogeneous metal spheres were calculated. The equivalence factors for the non-conservative metal homogeneous sphere systems were adjusted so that they were conservative. No equivalence factors were calculated for the ball-and-shell systems since the SARP assumes that only homogeneous or uniformly distributed material will be shipped in the 9972-9975 shipping casks, and an unnecessarily conservative critical mass may result if the ball-and-shell configurations are included

  16. Technical note: Equivalent genomic models with a residual polygenic effect.

    Science.gov (United States)

    Liu, Z; Goddard, M E; Hayes, B J; Reinhardt, F; Reents, R

    2016-03-01

    Routine genomic evaluations in animal breeding are usually based on either a BLUP with genomic relationship matrix (GBLUP) or single nucleotide polymorphism (SNP) BLUP model. For a multi-step genomic evaluation, these 2 alternative genomic models were proven to give equivalent predictions for genomic reference animals. The model equivalence was verified also for young genotyped animals without phenotypes. Due to incomplete linkage disequilibrium of SNP markers to genes or causal mutations responsible for genetic inheritance of quantitative traits, SNP markers cannot explain all the genetic variance. A residual polygenic effect is normally fitted in the genomic model to account for the incomplete linkage disequilibrium. In this study, we start by showing the proof that the multi-step GBLUP and SNP BLUP models are equivalent for the reference animals, when they have a residual polygenic effect included. Second, the equivalence of both multi-step genomic models with a residual polygenic effect was also verified for young genotyped animals without phenotypes. Additionally, we derived formulas to convert genomic estimated breeding values of the GBLUP model to its components, direct genomic values and residual polygenic effect. Third, we made a proof that the equivalence of these 2 genomic models with a residual polygenic effect holds also for single-step genomic evaluation. Both the single-step GBLUP and SNP BLUP models lead to equal prediction for genotyped animals with phenotypes (e.g., reference animals), as well as for (young) genotyped animals without phenotypes. Finally, these 2 single-step genomic models with a residual polygenic effect were proven to be equivalent for estimation of SNP effects, too. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  17. Pharmaceutical equivalence of gabapentin tablets with various extragranular binders Pharmaceutical equivalence of gabapentin tablets with various extragranular binders

    Directory of Open Access Journals (Sweden)

    SWATI C. JAGDALE

    2010-06-01

    Full Text Available Gabapentin is a high-dose drug widely used as an oral anti-epilepticagent. Due to high crystalline and has poor compaction properties it is difficult to form tablets by direct compression. The aim of this study was to develop gabapentin tablets, pharmaceutically equivalent to the reference product Neurontin (marketed in USA. Gabapentin 800mg tablets were produced by wet granulation by keeping intragranular binder as well as its concentration constant and by changing with various extragranular binders with its concentration (A = PVPK 30, B = HPMC 15 cps, C = Kollidon VA 64, D =Klucel EXF.The tablet having no weight, thickness and hardness variation and having appropriate, friability as well as disintegration profile were coated with a 3% film coating solution .Seven formulations F1 (A in lower concentration F2 (A in higher concentration, F3 (B in lower concentration and F4 (B in higher concentration, F5 (C in lower concentration, F6 (C in higher concentration, F7 (D in lower concentration were formulated. Among them F6 demonstrated adequate hardness, friability, disintegration, uniformity of content, and total drug dissolution after 45minutes. The dissimilarity factor (f1 is 5.93 and the similarity factor (f2 is 67.85. So F6 was found to be equivalent to Neurontin.Gabapentin is widely used as an oral anti-epileptic agent. However, owing to its high crystallinity and poor compaction properties, it is difficult to form tablets of this drug by direct compression. The aim of this study was to develop gabapentin tablets, pharmaceutically equivalent to the brand-name pioneer product Neurontin® (marketed in USA. Gabapentin 800mg tablets were produced by wet granulation with a constant concentration of intragranular binder and a varying concentration of extragranular binders (A = polyvinylpyrrolidone K30, B = hydroxypropylmethylcellulose 15 cps, C = Kollidon VA64, D =Klucel EXF. The tablets that did not vary in weight, thickness or hardness and had

  18. Apparent violation of the principle of equivalence and Killing horizons

    International Nuclear Information System (INIS)

    Zimmerman, R.L.; Farhoosh, H.; Oregon Univ., Eugene

    1980-01-01

    By means of the principle of equivalence it is deduced that the qualitative behavior of the Schwarzschild horizon about a uniformly accelerating particle. This result is confirmed for an exact solution of a uniformly accelerating object in the limit of small accelerations. For large accelerations the Schwarzschild horizon appears to violate the qualitative behavior established via the principle of equivalence. When similar arguments are extended to an observable such as the red shift between two observers, there is no departure from the results expected from the principle of equivalence. The resolution of the paradox is brought about by a compensating effect due to the Rindler horizon. (author)

  19. Investigation of pion-treated human skin nodules for therapeutic gain

    International Nuclear Information System (INIS)

    Kligerman, M.M.; Sala, J.M.; Wilson, S.; Yuhas, J.M.

    1978-01-01

    A patient with multiple metastatic tumor nodules in the skin, from a primary breast carcinoma, was treated with graded doses of pions and x rays to establish skin tolerance. She was followed up for 346 days, permitting observation of time to regrowth of the tumor nodules. All 16 of these had disappeared after treatment, without significant correlation with type of radiation or dose, or with nodule size. However, time to regrowth depended both on the type and the dose of radiation. Earlier, relative biological effectiveness (RBE), was established at 1.42 for acute skin injury. Using this RBE to normalize doses of pions and x rays causing equivalent acute skin injury, and plotting those doses vs time to regrowth of tumor nodules, yielded a therapeutic gain (37.5%) in favor of pions. No late skin or subcutaneous tissue changes were seen, and no qualitative difference between pions and x rays in late skin effects was observed

  20. Formal and physical equivalence in two cases in contemporary quantum physics

    Science.gov (United States)

    Fraser, Doreen

    2017-08-01

    The application of analytic continuation in quantum field theory (QFT) is juxtaposed to T-duality and mirror symmetry in string theory. Analytic continuation-a mathematical transformation that takes the time variable t to negative imaginary time-it-was initially used as a mathematical technique for solving perturbative Feynman diagrams, and was subsequently the basis for the Euclidean approaches within mainstream QFT (e.g., Wilsonian renormalization group methods, lattice gauge theories) and the Euclidean field theory program for rigorously constructing non-perturbative models of interacting QFTs. A crucial difference between theories related by duality transformations and those related by analytic continuation is that the former are judged to be physically equivalent while the latter are regarded as physically inequivalent. There are other similarities between the two cases that make comparing and contrasting them a useful exercise for clarifying the type of argument that is needed to support the conclusion that dual theories are physically equivalent. In particular, T-duality and analytic continuation in QFT share the criterion for predictive equivalence that two theories agree on the complete set of expectation values and the mass spectra and the criterion for formal equivalence that there is a "translation manual" between the physically significant algebras of observables and sets of states in the two theories. The analytic continuation case study illustrates how predictive and formal equivalence are compatible with physical inequivalence, but not in the manner of standard underdetermination cases. Arguments for the physical equivalence of dual theories must cite considerations beyond predictive and formal equivalence. The analytic continuation case study is an instance of the strategy of developing a physical theory by extending the formal or mathematical equivalence with another physical theory as far as possible. That this strategy has resulted in

  1. Modeling Stochastic Route Choice Behaviors with Equivalent Impedance

    Directory of Open Access Journals (Sweden)

    Jun Li

    2015-01-01

    Full Text Available A Logit-based route choice model is proposed to address the overlapping and scaling problems in the traditional multinomial Logit model. The nonoverlapping links are defined as a subnetwork, and its equivalent impedance is explicitly calculated in order to simply network analyzing. The overlapping links are repeatedly merged into subnetworks with Logit-based equivalent travel costs. The choice set at each intersection comprises only the virtual equivalent route without overlapping. In order to capture heterogeneity in perception errors of different sizes of networks, different scale parameters are assigned to subnetworks and they are linked to the topological relationships to avoid estimation burden. The proposed model provides an alternative method to model the stochastic route choice behaviors without the overlapping and scaling problems, and it still maintains the simple and closed-form expression from the MNL model. A link-based loading algorithm based on Dial’s algorithm is proposed to obviate route enumeration and it is suitable to be applied on large-scale networks. Finally a comparison between the proposed model and other route choice models is given by numerical examples.

  2. Development of dose equivalent meters based on microdosimetric principles

    International Nuclear Information System (INIS)

    Booz, J.

    1984-01-01

    In this paper, the employment of microdosimetric dose-equivalent meters in radiation protection is described considering the advantages of introducing microdosimetric methods into radiation protection, the technical suitability of such instruments for measuring dose equivalent, and finally technical requirements, constraints and solutions together with some examples of instruments and experimental results. The advantage of microdosimetric methods in radiation protection is illustrated with the evaluation of dose-mean quality factors in radiation fields of unknown composition and with the methods of evaluating neutron- and gamma-dose fractions. - It is shown that there is good correlation between dose-mean lineal energy, anti ysub(anti D), and the ICRP quality factor. - Neutron- and gamma-dose fractions of unknown radiation fields can be evaluated with microdosimetric proportional counters without recurrence to other instruments and methods. The problems of separation are discussed. The technical suitability of microdosimetric instruments for measuring dose equivalent is discussed considering the energy response to neutrons and photons and the sensitivity in terms of dose-equivalent rate. Then, considering technical requirements, constraints, and solutions, the problem of the large dynamic range in LET, the large dynamic range in pulse rate, geometry of sensitive volume and electrodes, evaluation of dose-mean quality factors, calibration methods, and uncertainties are discussed. (orig.)

  3. Water-equivalence of gel dosimeters for radiology medical imaging

    Energy Technology Data Exchange (ETDEWEB)

    Valente, M; Vedelago, J.; Perez, P. [Instituto de Fisica Enrique Gaviola - CONICET, Av. Medina Allende s/n, Ciudad Universitaria, X5000HUA, Cordoba (Argentina); Chacon, D.; Mattea, F. [Universidad Nacional de Cordoba, FAMAF, Laboratorio de Investigacion e Instrumentacion en Fisica Aplicada a la Medicina e Imagenes por Rayos X, Av. Medina Allende s/n, Ciudad Universitaria, X5000HUA Cordoba (Argentina); Velasquez, J., E-mail: valente@famaf.unc.edu.ar [ICOS Inmunomedica, Lago Puyehue 01745, Temuco (Chile)

    2017-10-15

    International dosimetry protocols are based on determinations of absorbed dose to water. Ideally, the phantom material should be water equivalent; that is, it should have the same absorption and scatter properties as water. This study presents theoretical, experimental and Monte Carlo modeling of water-equivalence of Fricke and polymer (NIPAM, PAGAT and itaconic acid ITABIS) gel dosimeters. Mass and electronic densities along with effective atomic number were calculated by means of theoretical approaches. Samples were scanned by standard computed tomography and high-resolution micro computed tomography. Photon mass attenuation coefficients and electron stopping powers were examined by Monte Carlo simulations. Theoretical, Monte Carlo and experimental results confirmed good water-equivalence for all gel dosimeters. Overall variations with respect to water in the low energy radiology range (up to 130 k Vp) were found to be less than 3% in average. (Author)

  4. Water-equivalence of gel dosimeters for radiology medical imaging

    International Nuclear Information System (INIS)

    Valente, M; Vedelago, J.; Perez, P.; Chacon, D.; Mattea, F.; Velasquez, J.

    2017-10-01

    International dosimetry protocols are based on determinations of absorbed dose to water. Ideally, the phantom material should be water equivalent; that is, it should have the same absorption and scatter properties as water. This study presents theoretical, experimental and Monte Carlo modeling of water-equivalence of Fricke and polymer (NIPAM, PAGAT and itaconic acid ITABIS) gel dosimeters. Mass and electronic densities along with effective atomic number were calculated by means of theoretical approaches. Samples were scanned by standard computed tomography and high-resolution micro computed tomography. Photon mass attenuation coefficients and electron stopping powers were examined by Monte Carlo simulations. Theoretical, Monte Carlo and experimental results confirmed good water-equivalence for all gel dosimeters. Overall variations with respect to water in the low energy radiology range (up to 130 k Vp) were found to be less than 3% in average. (Author)

  5. Conditions needed to give meaning to rad-equivalence principle

    International Nuclear Information System (INIS)

    Latarjet, R.

    1980-01-01

    To legislate on mutagenic chemical pollution the problem to be faced is similar to that tackled about 30 years ago regarding pollution by ionizing radiations. It would be useful to benefit from the work of these 30 years by establishing equivalences, if possible, between chemical mutagens and radiations. Inevitable mutagenic pollutions are considered here, especially those associated with fuel based energy production. As with radiations the legislation must derive from a compromise between the harmful and beneficial effects of the polluting system. When deciding on tolerance doses it is necessary to safeguard the biosphere without inflicting excessive restrictions on industry and on the economy. The present article discusses the conditions needed to give meaning to the notion of rad-equivalence. Some examples of already established equivalences are given, together with the first practical consequences which emerge [fr

  6. Equivalent operator preconditioning for elliptic problems

    Czech Academy of Sciences Publication Activity Database

    Axelsson, Owe; Karátson, J.

    2009-01-01

    Roč. 50, č. 3 (2009), s. 297-380 ISSN 1017-1398 Institutional research plan: CEZ:AV0Z30860518 Keywords : Elliptic problem * Conjugate gradient method * preconditioning * equivalent operators * compact operators Subject RIV: BA - General Mathematics Impact factor: 0.716, year: 2009 http://en.scientificcommons.org/42514649

  7. Thermoluminescence dosemeter for personal dose equivalent assessment

    International Nuclear Information System (INIS)

    Silva, T.A. da; Rosa, L.A.R. da; Campos, L.L.

    1995-01-01

    The possibility was investigated of utilising a Brazilian thermoluminescence individual dosemeter, usually calibrated in terms of photon dose equivalent, for the assessment of the personal dose equivalent, H p (d), at depths of 0.07 and 10 mm. The dosemeter uses four CaSO 4 :Dy thermoluminescent detectors, between different filters, as the sensitive materials. It was calibrated in gamma and X radiation fields in the energy range from 17 to 1250 keV. Linear combinations of the responses of three detectors, in this energy range, allow the evaluation of H p (0.07) and H p (10), for radiation incidence angles varying from 0 to 60 degrees, with an accuracy better than 35%. The method is not applicable to mixed photon-beta fields. (author)

  8. Symmetry adaptation, operator equivalents and magnetic resonance

    International Nuclear Information System (INIS)

    Kibler, M.; Chatterjee, R.

    1977-12-01

    Basic quantities for symmetry adaptation are discussed in connection with molecular and solid state physics. This gives rise to a formalism whose the central elements are operator equivalents adapted to a point group. Such symmetry adapted operator equivalents are defined in terms of Schwinger operators so that they cover the off-diagonal and diagonal cases. Special emphasis is put on the applications of the formalism to magnetic resonance. More specifically, it is shown how to apply the formalism to the construction, the study of the transformation properties, and the determination of the eigenstates of a generalized spin hamiltonian. Numerous examples are given as well as key tables relative to the chain SO(3) for making easy the application of the formalism to electron paramagnetic resonance [fr

  9. Equivalence between quantum simultaneous games and quantum sequential games

    OpenAIRE

    Kobayashi, Naoki

    2007-01-01

    A framework for discussing relationships between different types of games is proposed. Within the framework, quantum simultaneous games, finite quantum simultaneous games, quantum sequential games, and finite quantum sequential games are defined. In addition, a notion of equivalence between two games is defined. Finally, the following three theorems are shown: (1) For any quantum simultaneous game G, there exists a quantum sequential game equivalent to G. (2) For any finite quantum simultaneo...

  10. An equivalence between momentum and charge in string theory

    International Nuclear Information System (INIS)

    Horne, J.H.; Horowitz, G.T.; Steif, A.R.

    1992-01-01

    It is shown that for a translationally invariant solution to string theory, spacetime duality interchanges the momentum in the symmetry direction and the axion charge per unit length. As one application, we show explicitly that charged black strings are equivalent to boosted (uncharged) black strings. The extremal black strings (which correspond to the field outside of a fundamental macroscopic string) are equivalent to plane-fronted waves describing strings moving at the speed of light

  11. Equivalence transformations and differential invariants of a generalized nonlinear Schroedinger equation

    International Nuclear Information System (INIS)

    Senthilvelan, M; Torrisi, M; Valenti, A

    2006-01-01

    By using Lie's invariance infinitesimal criterion, we obtain the continuous equivalence transformations of a class of nonlinear Schroedinger equations with variable coefficients. We construct the differential invariants of order 1 starting from a special equivalence subalgebra E χ o . We apply these latter ones to find the most general subclass of variable coefficient nonlinear Schr?dinger equations which can be mapped, by means of an equivalence transformation of E χ o , to the well-known cubic Schroedinger equation. We also provide the explicit form of the transformation

  12. The importance of being equivalent: Newton's two models of one-body motion

    Science.gov (United States)

    Pourciau, Bruce

    2004-05-01

    As an undergraduate at Cambridge, Newton entered into his "Waste Book" an assumption that we have named the Equivalence Assumption (The Younger): "If a body move progressively in some crooked line [about a center of motion] ..., [then this] crooked line may bee conceived to consist of an infinite number of streight lines. Or else in any point of the croked line the motion may bee conceived to be on in the tangent". In this assumption, Newton somewhat imprecisely describes two mathematical models, a "polygonal limit model" and a "tangent deflected model", for "one-body motion", that is, for the motion of a "body in orbit about a fixed center", and then claims that these two models are equivalent. In the first part of this paper, we study the Principia to determine how the elder Newton would more carefully describe the polygonal limit and tangent deflected models. From these more careful descriptions, we then create Equivalence Assumption (The Elder), a precise interpretation of Equivalence Assumption (The Younger) as it might have been restated by Newton, after say 1687. We then review certain portions of the Waste Book and the Principia to make the case that, although Newton never restates nor even alludes to the Equivalence Assumption after his youthful Waste Book entry, still the polygonal limit and tangent deflected models, as well as an unspoken belief in their equivalence, infuse Newton's work on orbital motion. In particular, we show that the persuasiveness of the argument for the Area Property in Proposition 1 of the Principia depends crucially on the validity of Equivalence Assumption (The Elder). After this case is made, we present the mathematical analysis required to establish the validity of the Equivalence Assumption (The Elder). Finally, to illustrate the fundamental nature of the resulting theorem, the Equivalence Theorem as we call it, we present three significant applications: we use the Equivalence Theorem first to clarify and resolve questions

  13. Therapeutic Nanodevices

    Science.gov (United States)

    Lee, Stephen; Ruegsegger, Mark; Barnes, Philip; Smith, Bryan; Ferrari, Mauro

    Therapeutic nanotechnology offers minimally invasive therapies with high densities of function concentrated in small volumes, features that may reduce patient morbidity and mortality. Unlike other areas of nanotechnology, novel physical properties associated with nanoscale dimensionality are not the raison d'être of therapeutic nanotechnology, whereas the aggregation of multiple biochemical (or comparably precise) functions into controlled nanoarchitectures is. Multifunctionality is a hallmark of emerging nanotherapeutic devices, and multifunctionality can allow nanotherapeutic devices to perform multistep work processes, with each functional component contributing to one or more nanodevice subroutine such that, in aggregate, subroutines sum to a cogent work process. Cannonical nanotherapeutic subroutines include tethering (targeting) to sites of disease, dispensing measured doses of drug (or bioactive compound), detection of residual disease after therapy and communication with an external clinician/operator. Emerging nanotherapeutics thus blur the boundaries between medical devices and traditional pharmaceuticals. Assembly of therapeutic nanodevices generally exploits either (bio)material self-assembly properties or chemoselective bioconjugation techniques, or both. Given the complexity, composition, and the necessity for their tight chemical and structural definition inherent in the nature of nanotherapeutics, their cost of goods (COGs) might exceed that of (already expensive) biologics. Early therapeutic nanodevices will likely be applied to disease states which exhibit significant unmet patient need (cancer and cardiovascular disease), while application to other disease states well-served by conventional therapy may await perfection of nanotherapeutic design and assembly protocols.

  14. Effective prefiltration of X-ray tube assemblies and its specification in aluminium equivalents

    International Nuclear Information System (INIS)

    Meiler, J.

    1984-01-01

    It is shown that the Al equivalent of the prefiltration of an X-ray tube assembly varies significantly with the tube voltage, and hence the usual quotation of only one value without further specifications cannot suffice for the definition of the Al equivalent. The knowledge of the tube voltage, with which the equivalent was determined, is also important. The equivalent relationships can then be indicated for the total tube voltage range which is of interest. (orig.) [de

  15. Equivalent equations of motion for gravity and entropy

    International Nuclear Information System (INIS)

    Czech, Bartłomiej; Lamprou, Lampros; McCandlish, Samuel; Mosk, Benjamin; Sully, James

    2017-01-01

    We demonstrate an equivalence between the wave equation obeyed by the entanglement entropy of CFT subregions and the linearized bulk Einstein equation in Anti-de Sitter space. In doing so, we make use of the formalism of kinematic space https://www.doi.org/10.1007/JHEP10(2015)175 and fields on this space, introduced in https://www.doi.org/10.1007/JHEP07(2016)129. We show that the gravitational dynamics are equivalent to a gauge invariant wave-equation on kinematic space and that this equation arises in natural correspondence to the conformal Casimir equation in the CFT.

  16. An Equivalent Circuit of Longitudinal Vibration for a Piezoelectric Structure with Losses.

    Science.gov (United States)

    Yuan, Tao; Li, Chaodong; Fan, Pingqing

    2018-03-22

    Equivalent circuits of piezoelectric structures such as bimorphs and unimorphs conventionally focus on the bending vibration modes. However, the longitudinal vibration modes are rarely considered even though they also play a remarkable role in piezoelectric devices. Losses, especially elastic loss in the metal substrate, are also generally neglected, which leads to discrepancies compared with experiments. In this paper, a novel equivalent circuit with four kinds of losses is proposed for a beamlike piezoelectric structure under the longitudinal vibration mode. This structure consists of a slender beam as the metal substrate, and a piezoelectric patch which covers a partial length of the beam. In this approach, first, complex numbers are used to deal with four kinds of losses-elastic loss in the metal substrate, and piezoelectric, dielectric, and elastic losses in the piezoelectric patch. Next in this approach, based on Mason's model, a new equivalent circuit is developed. Using MATLAB, impedance curves of this structure are simulated by the equivalent circuit method. Experiments are conducted and good agreements are revealed between experiments and equivalent circuit results. It is indicated that the introduction of four losses in an equivalent circuit can increase the result accuracy considerably.

  17. Is the dose equivalent index a quantity to be measured

    International Nuclear Information System (INIS)

    Wagner, S.R.

    1980-01-01

    ICRP introduced the concept of Effective Dose Equivalent H(sub)E and fixed the basic limits of radiation exposure in terms of H(sub)I. As H(sub)E cannot be measured, ICRP stated that with external exposure to penetrating radiation the limitation of the Dose Equivalent Index H(sub)I would afford at least as good a level of protection. However, difficulties arise in measuring H(sub)I and in calibrating instruments in terms of H(sub)I, since the height and location of the dose equivalent maximum in the sphere which is the phantom used in the definition of H(sub)I, depend on the energy and the angular distribution of the incident radiation. That is, H(sub)I is not an additive quantity relative to the partial H(sub)I(sub)i-values of the different energy and angular components. Hence, 1) the distribution of dose equivalent in the sphere must be measured in full for a determination of H(sub)I, and 2) it is not possible to calibrate an instrument which does not exhibit the scattering and absorption properties of the sphere, consistently for arbitrary radiation fields in terms of H(sub)I. Thus the calibration in an unidirectional beam would infer an uncertainty which may amount to a factor of up to 4. This would hardly be tolerable as a base for radiation protection provisions. An alternative is to introduce operational quantities which are additive, e.g. 1) the sum of maxima of the dose equivalent distributions in the sphere produced by different radiation components, and 2) the mean dose equivalent in the sphere. Their relation to H(sub)E for different types of radiation and consequences on secondary limits are discussed. (H.K.)

  18. ESA GlobSnow Snow Water Equivalent (SWE)

    Data.gov (United States)

    National Aeronautics and Space Administration — The European Space Agency (ESA) Global Snow Monitoring for Climate Research (GlobSnow) snow water equivalent (SWE) v2.0 data record contains snow information derived...

  19. The Bohr--Einstein ''weighing-of-energy'' debate and the principle of equivalence

    International Nuclear Information System (INIS)

    Hughes, R.J.

    1990-01-01

    The Bohr--Einstein debate over the ''weighing of energy'' and the validity of the time--energy uncertainty relation is reexamined in the context of gravitation theories that do not respect the equivalence principle. Bohr's use of the equivalence principle is shown to be sufficient, but not necessary, to establish the validity of this uncertainty relation in Einstein's ''weighing-of-energy'' gedanken experiment. The uncertainty relation is shown to hold in any energy-conserving theory of gravity, and so a failure of the equivalence principle does not engender a failure of quantum mechanics. The relationship between the gravitational redshift and the equivalence principle is reviewed

  20. Macromolecular therapeutics.

    Science.gov (United States)

    Yang, Jiyuan; Kopeček, Jindřich

    2014-09-28

    This review covers water-soluble polymer-drug conjugates and macromolecules that possess biological activity without attached low molecular weight drugs. The main design principles of traditional and backbone degradable polymer-drug conjugates as well as the development of a new paradigm in nanomedicines - (low molecular weight) drug-free macromolecular therapeutics are discussed. To address the biological features of cancer, macromolecular therapeutics directed to stem/progenitor cells and the tumor microenvironment are deliberated. Finally, the future perspectives of the field are briefly debated. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. A Study on intelligent measurement of nuclear explosion equivalent in atmosphere

    International Nuclear Information System (INIS)

    Wang Desheng; Wu Xiaohong

    1999-01-01

    Measurement of nuclear explosion equivalent in atmosphere is an important subject for nuclear survey. Based on the relations between nuclear explosion equivalent and the minimum illuminance time of light radiation from nuclear explosion. The method of RC differential valley time detection and mean-time taking is presented the method, using a single-chip computer as a intelligent part, can realize intelligent measurement of minimum illuminance time with high reliability and low power consumption. This method provides a practical mean for quick, accurate and reliable measurement of nuclear explosion equivalent in atmosphere

  2. Extended Equivalence Principle: Implications for Gravity, Geometry and Thermodynamics

    OpenAIRE

    Sivaram, C.; Arun, Kenath

    2012-01-01

    The equivalence principle was formulated by Einstein in an attempt to extend the concept of inertial frames to accelerated frames, thereby bringing in gravity. In recent decades, it has been realised that gravity is linked not only with geometry of space-time but also with thermodynamics especially in connection with black hole horizons, vacuum fluctuations, dark energy, etc. In this work we look at how the equivalence principle manifests itself in these different situations where we have str...

  3. On Asymptotically Lacunary Statistical Equivalent Sequences of Order α in Probability

    Directory of Open Access Journals (Sweden)

    Işık Mahmut

    2017-01-01

    Full Text Available In this study, we introduce and examine the concepts of asymptotically lacunary statistical equivalent of order α in probability and strong asymptotically lacunary equivalent of order α in probability. We give some relations connected to these concepts.

  4. Behavior equivalence and compatibility of business process models with complex correspondences

    NARCIS (Netherlands)

    Weidlich, M.; Dijkman, R.M.; Weske, M.H.

    2012-01-01

    Once multiple models of a business process are created for different purposes or to capture different variants, verification of behaviour equivalence or compatibility is needed. Equivalence verification ensures that two business process models specify the same behaviour. Since different process

  5. A general method to quantify quasi-equivalence in icosahedral viruses.

    Science.gov (United States)

    Damodaran, K V; Reddy, Vijay S; Johnson, John E; Brooks, Charles L

    2002-12-06

    A quantitative, atom-based, method is described for comparing protein subunit interfaces in icosahedral virus capsids with quasi-equivalent surface lattices. An integrated, normalized value (between 0 and 1) based on equivalent residue contacts (Q-score) is computed for every pair of subunit interactions and scores that are significantly above zero readily identify interfaces that are quasi-equivalent to each other. The method was applied to all quasi-equivalent capsid structures (T=3, 4, 7 and 13) in the Protein Data Bank and the Q-scores were interpreted in terms of their structural underpinnings. The analysis allowed classification of T=3 structures into three groups with architectures that resemble different polyhedra with icosahedral symmetry. The preference of subunits to form dimers in the T=4 human Hepatitis B virus capsid (HBV) was clearly reflected in high Q-scores of quasi-equivalent dimers. Interesting differences between the classical T=7 capsid and polyoma-like capsids were also identified. Application of the method to the outer-shell of the T=13 Blue tongue virus core (BTVC) highlighted the modest distortion between the interfaces of the general trimers and the strict trimers of VP7 subunits. Furthermore, the method identified the quasi 2-fold symmetry in the inner capsids of the BTV and reovirus cores. The results show that the Q-scores of various quasi-symmetries represent a "fingerprint" for a particular virus capsid architecture allowing particle classification into groups based on their underlying structural and geometric features.

  6. The gauge principle vs. the equivalence principle

    International Nuclear Information System (INIS)

    Gates, S.J. Jr.

    1984-01-01

    Within the context of field theory, it is argued that the role of the equivalence principle may be replaced by the principle of gauge invariance to provide a logical framework for theories of gravitation

  7. Incorporating Measurement Non-Equivalence in a Cross-Study Latent Growth Curve Analysis.

    Science.gov (United States)

    Flora, David B; Curran, Patrick J; Hussong, Andrea M; Edwards, Michael C

    2008-10-01

    A large literature emphasizes the importance of testing for measurement equivalence in scales that may be used as observed variables in structural equation modeling applications. When the same construct is measured across more than one developmental period, as in a longitudinal study, it can be especially critical to establish measurement equivalence, or invariance, across the developmental periods. Similarly, when data from more than one study are combined into a single analysis, it is again important to assess measurement equivalence across the data sources. Yet, how to incorporate non-equivalence when it is discovered is not well described for applied researchers. Here, we present an item response theory approach that can be used to create scale scores from measures while explicitly accounting for non-equivalence. We demonstrate these methods in the context of a latent curve analysis in which data from two separate studies are combined to create a single longitudinal model spanning several developmental periods.

  8. [Nuclear transfer and therapeutic cloning].

    Science.gov (United States)

    Xu, Xiao-Ming; Lei, An-Min; Hua, Jin-Lian; Dou, Zhong-Ying

    2005-03-01

    Nuclear transfer and therapeutic cloning have widespread and attractive prospects in animal agriculture and biomedical applications. We reviewed that the quality of oocytes and nuclear reprogramming of somatic donor cells were the main reasons of the common abnormalities in cloned animals and the low efficiency of cloning and showed the problems and outlets in therapeutic cloning, such as some basic problems in nuclear transfer affected clinical applications of therapeutic cloning. Study on isolation and culture of nuclear transfer embryonic stem (ntES) cells and specific differentiation of ntES cells into important functional cells should be emphasized and could enhance the efficiency. Adult stem cells could help to cure some great diseases, but could not replace therapeutic cloning. Ethics also impeded the development of therapeutic cloning. It is necessary to improve many techniques and reinforce the research of some basic theories, then somatic nuclear transfer and therapeutic cloning may apply to agriculture reproduction and benefit to human life better.

  9. Therapeutic administration of enrofloxacin in mice does not select for fluoroquinolone resistance in Campylobacter jejuni.

    Science.gov (United States)

    Inglis, G Douglas; Zaytsoff, S J M; Selinger, L Brent; Taboada, Eduardo N; Uwiera, R R E

    2018-05-11

    Enrofloxacin is registered for therapeutic use in beef cattle to treat bovine respiratory disease in Canada. A murine model was used to experimentally examine the impact of therapeutic administration of enrofloxacin on fluoroquinolone resistance development in Campylobacter jejuni. Administration of enrofloxacin to mice via subcutaneous injection or per os routes resulted in equivalent levels of bioactive enrofloxacin within the intestine, but bioactivity was short-lived (Enrofloxacin administration did not affect densities of total bacteria, Firmicutes, or Bacteroidetes in digesta, and had modest impacts on densities of Enterobacteriaceae. All mice inoculated with C. jejuni NCTC 11168 became persistently colonized by the bacterium. Enrofloxacin reduced C. jejuni cell densities within the cecal and colonic digesta for all treatments, and densities shed in feces as a function of antibiotic duration. None of the C. jejuni isolates recovered from mice after administration of enrofloxacin (n=260) developed resistance to ciprofloxacin regardless of method or duration of administration. Furthermore, only modest shifts in the minimum inhibitory concentration of the isolates by treatment were noted. The study findings indicate that the risk posed by short-term subcutaneous administration of enrofloxacin for the development of fluoroquinolone resistance in mammals is low.

  10. Developing equivalent circuits for radial distribution networks

    Energy Technology Data Exchange (ETDEWEB)

    Prada, Ricardo; Coelho, Agnelo; Rodrigues, Anselmo [Catholic University of Rio de Janeiro (PUC-Rio), RJ (Brazil). Dept. of Electrical Engineering], Emails: prada@ele.puc-rio.br, agnelo@ele.puc-rio.br, nebulok_99@yahoo.com; Silva, Maria da Guia da [Federal University of Maranhao, Sao Luiz, MA (Brazil). Dept. of Electrical Engineering

    2009-07-01

    This paper presents a method for evaluating External Equivalent in Electric Distribution Networks (EDN).The proposed method has as its main objectives the reduction of the computational costs in distribution network reconfiguration, investigation of the optimal allocation of banks of capacitors, investigation of the allocation of distributed generation, etc. In these sorts of problems a large number of alternative projects must be assessed in order to identify the optimal solution. The optimal solution comes up with the voltage level in the load points within specified limits. Consequently, the EDN must retain the external network load points but without major increasing in the dimension of the equivalent circuit. The proposed method has been tested and validated in a substation of the Electricity Utility of Maranhao - CEMAR, in Brazil. (author)

  11. Frontiers in nano-therapeutics

    CERN Document Server

    Tasnim, Nishat; Sai Krishna, Katla; Kalagara, Sudhakar; Narayan, Mahesh; Noveron, Juan C; Joddar, Binata

    2017-01-01

    This brief highlights recent research advances in the area of nano-therapeutics. Nanotechnology holds immense potential for application in a wide range of biological and engineering applications such as molecular sensors for disease diagnosis, therapeutic agents for the treatment of diseases, a vehicle for delivering therapeutics and imaging agents for theranostic applications, both in-vitro and in-vivo. The brief is grouped into the following sections namely, A) Discrete Nanosystems ; B) Anisotropic Nanoparticles; C) Nano-films/coated/layered and D) Nano-composites.

  12. Rethinking Therapeutic Misconception in Biobanking

    DEFF Research Database (Denmark)

    Tupasela, Aaro; Snell, Karoliina; Cañada, Jose

    2017-01-01

    Some authors have noted that in biobank research participants may be guided by what is called therapeutic misconception, whereby participants attribute therapeutic intent to research procedures.This article argues that the notion of therapeutic misconception is increasingly less justified when...... underpinnings for the need to separate research and treatment, and thus the notion of therapeutic misconception in the fi rst place. We call this tension between research and treatment ambivalent research advancement to highlight the difficulties that various actors have in managing such shifts within...

  13. Therapeutic Inertia and Treatment Intensification.

    Science.gov (United States)

    Josiah Willock, Robina; Miller, Joseph B; Mohyi, Michelle; Abuzaanona, Ahmed; Muminovic, Meri; Levy, Phillip D

    2018-01-29

    This review aims to emphasize how therapeutic inertia, the failure of clinicians to intensify treatment when blood pressure rises or remains above therapeutic goals, contributes to suboptimal blood pressure control in hypertensive populations. Studies reveal that the therapeutic inertia is quite common and contributes to suboptimal blood pressure control. Quality improvement programs and standardized approaches to support antihypertensive treatment intensification are ways to combat therapeutic inertia. Furthermore, programs that utilize non-physician medical professionals such as pharmacists and nurses demonstrate promise in mitigating the effects of this important problem. Therapeutic inertia impedes antihypertensive management and requires a broad effort to reduce its effects. There is an ongoing need for renewed focus and research in this area to improve hypertension control.

  14. 76 FR 69246 - Application for New Awards; High School Equivalency Program

    Science.gov (United States)

    2011-11-08

    ..., engineering and mathematics (STEM) education. The fourth priority is an invitational priority for applications... DEPARTMENT OF EDUCATION Application for New Awards; High School Equivalency Program AGENCY: Office... High School Equivalency Program (HEP) Notice inviting applications for new awards for fiscal year (FY...

  15. Evaluation of Permacol as a cultured skin equivalent.

    Science.gov (United States)

    MacLeod, T M; Cambrey, A; Williams, G; Sanders, R; Green, C J

    2008-12-01

    Skin loss following severe burn requires prompt wound closure to avoid such complications as fluid and electrolyte imbalance, infection, immune suppression, and pain. In clinical situations in which insufficient donor skin is available, the development of cultured skin equivalents (dermal matrices seeded with keratinocytes and fibroblasts) may provide a useful alternative. The aim of this study was to assess the suitability of a porcine-derived dermal collagen matrix (Permacol) to function as a cultured skin equivalent in supporting the growth of keratinocytes in vitro and providing cover to full thickness wounds in the BALB C/nude mouse model. A histological comparison was against Glycerol treated-Ethylene Oxide Sterilised Porcine Dermis (Gly-EO Dermis) which has successfully been used as a cultured skin equivalent in previous studies. Both Gly-EO Dermis and to a lesser extent Permacol were able to support the growth of cultured keratinocytes following a 16-day period of cell culture, however, this study was only able to demonstrate the presence of an epidermal layer on Gly-EO dermis 2 weeks after grafting onto full-thickness wounds in the BALB C/nude mouse model.

  16. Quantum mechanics in noninertial reference frames: Violations of the nonrelativistic equivalence principle

    International Nuclear Information System (INIS)

    Klink, W.H.; Wickramasekara, S.

    2014-01-01

    In previous work we have developed a formulation of quantum mechanics in non-inertial reference frames. This formulation is grounded in a class of unitary cocycle representations of what we have called the Galilean line group, the generalization of the Galilei group that includes transformations amongst non-inertial reference frames. These representations show that in quantum mechanics, just as is the case in classical mechanics, the transformations to accelerating reference frames give rise to fictitious forces. A special feature of these previously constructed representations is that they all respect the non-relativistic equivalence principle, wherein the fictitious forces associated with linear acceleration can equivalently be described by gravitational forces. In this paper we exhibit a large class of cocycle representations of the Galilean line group that violate the equivalence principle. Nevertheless the classical mechanics analogue of these cocycle representations all respect the equivalence principle. -- Highlights: •A formulation of Galilean quantum mechanics in non-inertial reference frames is given. •The key concept is the Galilean line group, an infinite dimensional group. •A large class of general cocycle representations of the Galilean line group is constructed. •These representations show violations of the equivalence principle at the quantum level. •At the classical limit, no violations of the equivalence principle are detected

  17. Multilevel Optimization Framework for Hierarchical Stiffened Shells Accelerated by Adaptive Equivalent Strategy

    Science.gov (United States)

    Wang, Bo; Tian, Kuo; Zhao, Haixin; Hao, Peng; Zhu, Tianyu; Zhang, Ke; Ma, Yunlong

    2017-06-01

    In order to improve the post-buckling optimization efficiency of hierarchical stiffened shells, a multilevel optimization framework accelerated by adaptive equivalent strategy is presented in this paper. Firstly, the Numerical-based Smeared Stiffener Method (NSSM) for hierarchical stiffened shells is derived by means of the numerical implementation of asymptotic homogenization (NIAH) method. Based on the NSSM, a reasonable adaptive equivalent strategy for hierarchical stiffened shells is developed from the concept of hierarchy reduction. Its core idea is to self-adaptively decide which hierarchy of the structure should be equivalent according to the critical buckling mode rapidly predicted by NSSM. Compared with the detailed model, the high prediction accuracy and efficiency of the proposed model is highlighted. On the basis of this adaptive equivalent model, a multilevel optimization framework is then established by decomposing the complex entire optimization process into major-stiffener-level and minor-stiffener-level sub-optimizations, during which Fixed Point Iteration (FPI) is employed to accelerate convergence. Finally, the illustrative examples of the multilevel framework is carried out to demonstrate its efficiency and effectiveness to search for the global optimum result by contrast with the single-level optimization method. Remarkably, the high efficiency and flexibility of the adaptive equivalent strategy is indicated by compared with the single equivalent strategy.

  18. Assaults by Mentally Disordered Offenders in Prison: Equity and Equivalence.

    Science.gov (United States)

    Hales, Heidi; Dixon, Amy; Newton, Zoe; Bartlett, Annie

    2016-06-01

    Managing the violent behaviour of mentally disordered offenders (MDO) is challenging in all jurisdictions. We describe the ethical framework and practical management of MDOs in England and Wales in the context of the move to equivalence of healthcare between hospital and prison. We consider the similarities and differences between prison and hospital management of the violent and challenging behaviours of MDOs. We argue that both types of institution can learn from each other and that equivalence of care should extend to equivalence of criminal proceedings in court and prisons for MDOs. We argue that any adjudication process in prison for MDOs is enhanced by the relevant involvement of mental health professionals and the articulation of the ethical principles underpinning health and criminal justice practices.

  19. ON THE EQUIVALENCE OF THE ABEL EQUATION

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    This article uses the reflecting function of Mironenko to study some complicated differential equations which are equivalent to the Abel equation. The results are applied to discuss the behavior of solutions of these complicated differential equations.

  20. New equivalent lumped electrical circuit for piezoelectric transformers.

    Science.gov (United States)

    Gonnard, Paul; Schmitt, P M; Brissaud, Michel

    2006-04-01

    A new equivalent circuit is proposed for a contour-vibration-mode piezoelectric transformer (PT). It is shown that the usual lumped equivalent circuit derived from the conventional Mason approach is not accurate. The proposed circuit, built on experimental measurements, makes an explicit difference between the elastic energies stored respectively on the primary and secondary parts. The experimental and theoretical resonance frequencies with the secondary in open or short circuit are in good agreement as well as the output "voltage-current" characteristic and the optimum efficiency working point. This circuit can be extended to various PT configurations and appears to be a useful tool for modeling electronic devices that integrate piezoelectric transformers.

  1. Waste Determination Equivalency - 12172

    Energy Technology Data Exchange (ETDEWEB)

    Freeman, Rebecca D. [Savannah River Remediation (United States)

    2012-07-01

    by the Secretary of Energy in January of 2006 based on proposed processing techniques with the expectation that it could be revised as new processing capabilities became viable. Once signed, however, it became evident that any changes would require lengthy review and another determination signed by the Secretary of Energy. With the maturation of additional salt removal technologies and the extension of the SWPF start-up date, it becomes necessary to define 'equivalency' to the processes laid out in the original determination. For the purposes of SRS, any waste not processed through Interim Salt Processing must be processed through SWPF or an equivalent process, and therefore a clear statement of the requirements for a process to be equivalent to SWPF becomes necessary. (authors)

  2. Chemiluminescence-based multivariate sensing of local equivalence ratios in premixed atmospheric methane-air flames

    Energy Technology Data Exchange (ETDEWEB)

    Tripathi, Markandey M.; Krishnan, Sundar R.; Srinivasan, Kalyan K.; Yueh, Fang-Yu; Singh, Jagdish P.

    2011-09-07

    Chemiluminescence emissions from OH*, CH*, C2, and CO2 formed within the reaction zone of premixed flames depend upon the fuel-air equivalence ratio in the burning mixture. In the present paper, a new partial least square regression (PLS-R) based multivariate sensing methodology is investigated and compared with an OH*/CH* intensity ratio-based calibration model for sensing equivalence ratio in atmospheric methane-air premixed flames. Five replications of spectral data at nine different equivalence ratios ranging from 0.73 to 1.48 were used in the calibration of both models. During model development, the PLS-R model was initially validated with the calibration data set using the leave-one-out cross validation technique. Since the PLS-R model used the entire raw spectral intensities, it did not need the nonlinear background subtraction of CO2 emission that is required for typical OH*/CH* intensity ratio calibrations. An unbiased spectral data set (not used in the PLS-R model development), for 28 different equivalence ratio conditions ranging from 0.71 to 1.67, was used to predict equivalence ratios using the PLS-R and the intensity ratio calibration models. It was found that the equivalence ratios predicted with the PLS-R based multivariate calibration model matched the experimentally measured equivalence ratios within 7%; whereas, the OH*/CH* intensity ratio calibration grossly underpredicted equivalence ratios in comparison to measured equivalence ratios, especially under rich conditions ( > 1.2). The practical implications of the chemiluminescence-based multivariate equivalence ratio sensing methodology are also discussed.

  3. Microdosimetry of high LET therapeutic beams

    International Nuclear Information System (INIS)

    Ito, Akira

    1980-01-01

    Experimental microdosimetry of high LET therapeutic beams were presented. The cyclotron produced fast neutron beams at IMS, TAMVEC and NRL, a reactor fast neutron at YAYOI, a proctor beam at Harvard and a pion beam at TRIUMF are included. Measurements were performed with a conventional tissue equivalent spherical proportional counter with a logarithmic amplifier which made the recording and analysis quite simple. All the energy deposition spectra were analysed in the conventional manner and anti y F, anti y D as well as anti y D* were calculated. The spectra and their mean lineal energies showed wide variations, depending on the particle type, energy, position in phantom. Fractional contribution of elemental particles ( electron, muon, pion, proton, alpha and so on) to the total dose were analysed. For fast neutron beams, the y spectra stayed almost constant at any depth along the central axis in the phantom. The y spectra of proton beam changed slightly along the depth. On the other side, the y spectra of pion beam change drastically in the phantom between plateau and dose peak region. A novel technique of time-of-flight microdosimetry was employed, which made it possible to separate the fractional contribution of contaminant electrons and muons out of pions. Finally, a map of the radiation quality for all the beams is presented and its significances are discussed. (author)

  4. Equivalence of velocity-level and acceleration-level redundancy-resolution of manipulators

    International Nuclear Information System (INIS)

    Cai Binghuang; Zhang Yunong

    2009-01-01

    The equivalence of velocity-level and acceleration-level redundancy resolution of robot manipulators is investigated in this Letter. Theoretical analysis based on gradient-descent method and computer simulations based on PUMA560 robot manipulator both demonstrate the equivalence of redundancy-resolution schemes at different levels.

  5. Teacher ratings of ODD symptoms: measurement equivalence across Malaysian Malay, Chinese and Indian children.

    Science.gov (United States)

    Gomez, Rapson

    2014-04-01

    The study examined the measurement equivalence for teacher ratings across Malaysian Malay, Chinese and Indian children. Malaysian teachers completed ratings of the ODD symptoms for 574 Malay, 247 Chinese and 98 Indian children. The results supported the equivalences for the configural, metric, and error variances models, and the equivalences for ODD latent variances and mean scores. Together, these findings suggest good support for measurement and structural equivalences of the ODD symptoms across these ethnic groups. The theoretical and clinical implications of the findings for cross-cultural equivalence of the ODD symptoms are discussed. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Review of Recent Development of Dynamic Wind Farm Equivalent Models Based on Big Data Mining

    Science.gov (United States)

    Wang, Chenggen; Zhou, Qian; Han, Mingzhe; Lv, Zhan’ao; Hou, Xiao; Zhao, Haoran; Bu, Jing

    2018-04-01

    Recently, the big data mining method has been applied in dynamic wind farm equivalent modeling. In this paper, its recent development with present research both domestic and overseas is reviewed. Firstly, the studies of wind speed prediction, equivalence and its distribution in the wind farm are concluded. Secondly, two typical approaches used in the big data mining method is introduced, respectively. For single wind turbine equivalent modeling, it focuses on how to choose and identify equivalent parameters. For multiple wind turbine equivalent modeling, the following three aspects are concentrated, i.e. aggregation of different wind turbine clusters, the parameters in the same cluster, and equivalence of collector system. Thirdly, an outlook on the development of dynamic wind farm equivalent models in the future is discussed.

  7. Accuracy limits of the equivalent field method for irregular photon fields

    International Nuclear Information System (INIS)

    Sanz, Dario Esteban

    2002-01-01

    A mathematical approach is developed to evaluate the accuracy of the equivalent field method using basic clinical photon beam data. This paper presents an analytical calculation of dose errors arising when field equivalencies, calculated at a certain reference depth, are translated to other depths. The phantom scatter summation is expressed as a Riemann-Stieltjes integral and two categories of irregular fields are introduced: uniform and multiform. It is shown that multiform fields produce errors whose magnitudes are nearly twice those corresponding to uniform fields in extreme situations. For uniform field shapes, the maximum, local, relative dose errors, when the equivalencies are calculated at 10 cm depth on the central axis and translated to a depth of 30 cm, are 3.8% and 8.8% for 6 MV and cobalt-60 photon beams, respectively. In terms of maximum dose those errors are within 1-2%. This supports the conclusion that the equivalencies between rectangular fields, which are examples of uniform fields, are applicable to dose ratio functions irrespective of beam energy. However, the magnitude of such errors could be of importance when assessing the exit dose for in vivo monitoring. This work provides a better understanding of the influence of the irregular field shapes on the accuracy of the equivalent field method. (author)

  8. Comparison of power pulses from homogeneous and time-average-equivalent models

    International Nuclear Information System (INIS)

    De, T.K.; Rouben, B.

    1995-01-01

    The time-average-equivalent model is an 'instantaneous' core model designed to reproduce the same three dimensional power distribution as that generated by a time-average model. However it has been found that the time-average-equivalent model gives a full-core static void reactivity about 8% smaller than the time-average or homogeneous models. To investigate the consequences of this difference in static void reactivity in time dependent calculations, simulations of the power pulse following a hypothetical large-loss-of-coolant accident were performed with a homogeneous model and compared with the power pulse from the time-average-equivalent model. The results show that there is a much smaller difference in peak dynamic reactivity than in static void reactivity between the two models. This is attributed to the fact that voiding is not complete, but also to the retardation effect of the delayed-neutron precursors on the dynamic flux shape. The difference in peak reactivity between the models is 0.06 milli-k. The power pulses are essentially the same in the two models, because the delayed-neutron fraction in the time-average-equivalent model is lower than in the homogeneous model, which compensates for the lower void reactivity in the time-average-equivalent model. (author). 1 ref., 5 tabs., 9 figs

  9. Effect of epoxide equivalent on microstructure of epoxy/rectorite nanocomposite studied by positrons

    International Nuclear Information System (INIS)

    Liu, L.M.; Fang, P.F.; Zhang, S.P.; Wang, S.J.

    2005-01-01

    The epoxy/rectorite nanocomposites with different epoxide equivalent ranging from 188 to 1110 were prepared and the effects of epoxide equivalent on microstructure of materials were studied by X-ray diffraction (XRD) and positron annihilation lifetime spectroscope (PALS). In nanocomposites, the formation of exfoliated structure was observed from XRD pattern at epoxide equivalent >263. The PALS measurements reveal that the fractional free volume in nanocomposites was strongly affected by epoxide equivalent, in particular, the free-volume concentration was dramatically decreased with the increasing epoxide equivalent from 188 to 263, and the S parameter indicates the rectorite structure change and the high sensitivity of positron annihilation to the entry of rectorite into epoxy. These results indicate that positron annihilation characteristics are useful for study the microstructure of epoxy/rectorite nanocomposites

  10. The equivalent incidence angle for porous absorbers backed by a hard surface

    DEFF Research Database (Denmark)

    Jeong, Cheol-Ho; Brunskog, Jonas

    2013-01-01

    experiment using a free-field absorption measurement technique with a source at the equivalent angle. This study investigates the equivalent angle for locally and extendedly reacting porous media mainly by a numerical approach: Numerical minimizations of a cost function that is the difference between...... coefficients by free-field techniques, a broad incidence angle range can be suggested: 20 hi65 for extended reaction and hi65 for locally reacting porous absorbers, if an average difference of 0.05 is allowed.......An equivalent incidence angle is defined as the incidence angle at which the oblique incidence absorption coefficient best approximates the random incidence absorption coefficient. Once the equivalent angle is known, the random incidence absorption coefficient can be estimated by a single...

  11. On the equivalence of cyclic and quasi-cyclic codes over finite fields

    Directory of Open Access Journals (Sweden)

    Kenza Guenda

    2017-07-01

    Full Text Available This paper studies the equivalence problem for cyclic codes of length $p^r$ and quasi-cyclic codes of length $p^rl$. In particular, we generalize the results of Huffman, Job, and Pless (J. Combin. Theory. A, 62, 183--215, 1993, who considered the special case $p^2$. This is achieved by explicitly giving the permutations by which two cyclic codes of prime power length are equivalent. This allows us to obtain an algorithm which solves the problem of equivalency for cyclic codes of length $p^r$ in polynomial time. Further, we characterize the set by which two quasi-cyclic codes of length $p^rl$ can be equivalent, and prove that the affine group is one of its subsets.

  12. Long-Term Impact of Immunosuppressants at Therapeutic Doses on Male Reproductive System in Unilateral Nephrectomized Rats: A Comparative Study

    Directory of Open Access Journals (Sweden)

    Yehui Chen

    2013-01-01

    Full Text Available Cyclosporine, tacrolimus, and sirolimus are commonly used in renal transplant recipients to prevent rejection. However, information for comparative effects of these agents on the male productive system is extremely limited and controversial. In a physiologically and clinically relevant rat model of unilateral nephrectomy, we demonstrated that long-term oral administration of both cyclosporine and sirolimus at doses equivalent to the therapeutic levels used for postrenal transplant patients significantly affects testicular development and the hypothalamic-pituitary-gonadal axis accompanied by profound histological changes of testicular structures on both light and electron microscopic examinations. Spermatogenesis was also severely impaired as indicated by low total sperm counts along with reduction of sperm motility and increase in sperm abnormality after treatment with these agents, which may lead to male infertility. On the other hand, treatment with therapeutic dose of tacrolimus only induced mild reduction of sperm count without histological evidence of testicular injury. The current study clearly demonstrates that commonly used immunosuppressants have various impacts on male reproductive system even at therapeutic levels. Our data provide useful information for the assessment of male infertility in renal transplant recipients who wish to father children. Clinical trials to address these issues should be urged.

  13. Methodological Issues in Cross-Cultural Counseling Research: Equivalence, Bias, and Translations

    Science.gov (United States)

    Aegisdottir, Stefania; Gerstein, Lawrence A.; Cinarbas, Deniz Canel

    2008-01-01

    Concerns about the cross-cultural validity of constructs are discussed, including equivalence, bias, and translation procedures. Methods to enhance equivalence are described, as are strategies to evaluate and minimize types of bias. Recommendations for translating instruments are also presented. To illustrate some challenges of cross-cultural…

  14. A Technique of Teaching the Principle of Equivalence at Ground Level

    Science.gov (United States)

    Lubrica, Joel V.

    2016-01-01

    This paper presents one way of demonstrating the Principle of Equivalence in the classroom. Teaching the Principle of Equivalence involves someone experiencing acceleration through empty space, juxtaposed with the daily encounter with gravity. This classroom activity is demonstrated with a water-filled bottle containing glass marbles and…

  15. Exact equivalent straight waveguide model for bent and twisted waveguides

    DEFF Research Database (Denmark)

    Shyroki, Dzmitry

    2008-01-01

    Exact equivalent straight waveguide representation is given for a waveguide of arbitrary curvature and torsion. No assumptions regarding refractive index contrast, isotropy of materials, or particular morphology in the waveguide cross section are made. This enables rigorous full-vector modeling...... of in-plane curved or helically wound waveguides with use of available simulators for straight waveguides without the restrictions of the known approximate equivalent-index formulas....

  16. Personal dose equivalent conversion coefficients for electrons to 1 Ge V.

    Science.gov (United States)

    Veinot, K G; Hertel, N E

    2012-04-01

    In a previous paper, conversion coefficients for the personal dose equivalent, H(p)(d), for photons were reported. This note reports values for electrons calculated using similar techniques. The personal dose equivalent is the quantity used to approximate the protection quantity effective dose when performing personal dosemeter calibrations and in practice the personal dose equivalent is determined using a 30×30×15 cm slab-type phantom. Conversion coefficients to 1 GeV have been calculated for H(p)(10), H(p)(3) and H(p)(0.07) in the recommended slab phantom. Although the conversion coefficients were determined for discrete incident energies, analytical fits of the conversion coefficients over the energy range are provided using a similar formulation as in the photon results previously reported. The conversion coefficients for the personal dose equivalent are compared with the appropriate protection quantity, calculated according to the recommendations of the latest International Commission on Radiological Protection guidance. Effects of eyewear on H(p)(3) are also discussed.

  17. Gauge equivalence between two-boson KP hierarchies

    International Nuclear Information System (INIS)

    Aratyn, H.

    1994-01-01

    In this paper it is explained the status of the two-boson KP hierarchy, which appears in this setting as an invariant subspace of the coadjoint orbit within the KP l=1 hierarchy. We will work with two main cases of two-boson KP hierarchies, one defined within KP l=1 hierarchy will be called Faa di Bruno KP hierarchy, while the second defined within KP hierarchy for a quadratic two-boson KP hierarchy. It will be established for them the gauge invariance playing the role of generalized Miura transformations. It is emphasized the symplectic character of equivalence of KP l=1 and KP. It is also made a point that the gauge equivalence established for two-boson systems is valid for an arbitrary n-th Poisson bracket structure and not only the first Poisson bracket structure. (author). 7 refs

  18. Equivalent Sensor Radiance Generation and Remote Sensing from Model Parameters. Part 1; Equivalent Sensor Radiance Formulation

    Science.gov (United States)

    Wind, Galina; DaSilva, Arlindo M.; Norris, Peter M.; Platnick, Steven E.

    2013-01-01

    In this paper we describe a general procedure for calculating equivalent sensor radiances from variables output from a global atmospheric forecast model. In order to take proper account of the discrepancies between model resolution and sensor footprint the algorithm takes explicit account of the model subgrid variability, in particular its description of the probably density function of total water (vapor and cloud condensate.) The equivalent sensor radiances are then substituted into an operational remote sensing algorithm processing chain to produce a variety of remote sensing products that would normally be produced from actual sensor output. This output can then be used for a wide variety of purposes such as model parameter verification, remote sensing algorithm validation, testing of new retrieval methods and future sensor studies. We show a specific implementation using the GEOS-5 model, the MODIS instrument and the MODIS Adaptive Processing System (MODAPS) Data Collection 5.1 operational remote sensing cloud algorithm processing chain (including the cloud mask, cloud top properties and cloud optical and microphysical properties products.) We focus on clouds and cloud/aerosol interactions, because they are very important to model development and improvement.

  19. Weak equivalence classes of complex vector bundles

    Czech Academy of Sciences Publication Activity Database

    Le, Hong-Van

    LXXVII, č. 1 (2008), s. 23-30 ISSN 0862-9544 R&D Projects: GA AV ČR IAA100190701 Institutional research plan: CEZ:AV0Z10190503 Keywords : chern classes * complex Grassmannians weak equivalence Subject RIV: BA - General Mathematics

  20. A study on assessment of bone mass from aluminum-equivalent image by digital imaging system

    International Nuclear Information System (INIS)

    Kim, Jin Soo; Kim, Jae Duck; Choi, Eui Hwan

    1997-01-01

    The purpose of this study was to evaluated the method for quantitative assessment of bone mass from aluminum-equivalent value of hydroxyapatite by using digital imaging system consisted of Power Macintosh 7200/120, 15-inch color monitor, and GT-9000 scanner with transparency unit. After aluminum-equivalent image made from correlation between aluminum thickness and grey scale, the accuracy of conversion to mass from aluminum-equivalent value was evaluated. Measured bone mass was compared with converted bone mass from aluminum-equivalent value of hydroxyapatite block by correlation formula between aluminum-equivalent value of hydroxy apatite block and hydroxyapatite mass. The results of this study were as follows : 1. Correlation between aluminum thickness and grey level for obtaining aluminum-equivalent image was high positively associated (r2=0.99). Converted masses from aluminum-equivalent value were very similar to measured masses. There was, statistically, no significant difference (P<0.05) between them. 2. Correlation between hydroxyapatite aluminum-equivalent and hydroxyapatite mass was shown to linear relation (r2 =0.95). 3. Converted masses from aluminum-equivalent value of 3 dry mandible segments were similar to measured masses. The difference between the exposure directions was not significantly different (P<0.05).

  1. 29 CFR 4.177 - Discharging fringe benefit obligations by equivalent means.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Discharging fringe benefit obligations by equivalent means... CONTRACTS Compensation Standards Compliance with Compensation Standards § 4.177 Discharging fringe benefit obligations by equivalent means. (a) In general. (1) Section 2(a)(2) of the Act, which provides for fringe...

  2. Protective aprons in imaging departments: manufacturer stated lead equivalence values require validation

    International Nuclear Information System (INIS)

    Finnerty, M.; Brennan, P.C.

    2005-01-01

    The composition of protective aprons worn by X-ray personnel to shield against secondary radiation is changing. Lead is being replaced by either lead-free or composite (lead with other high atomic numbered elements) materials. These newer aprons are categorised by manufacturers in terms of lead equivalent values, but it is unclear how these stated values compare with actual lead equivalent values. In this work, the actual lead equivalence of 41 protective aprons from four manufacturers, all specified as having 0.25 mm lead equivalence, were investigated with transmission experiments at 70 and 100 kVp. All aprons were in current use. The aprons were screened for defects, and age, weight and design was recorded along with details of associated quality assurance (QA). Out of the 41 protective aprons examined for actual lead equivalence, 73% were outside tolerance levels, with actual levels in some aprons demonstrating less than half of the nominal values. The lack of compatibility between actual and nominal lead equivalent values was demonstrated by aprons from three of the four manufacturers investigated. The area of the defects found on screening of the protective aprons were within recommendations. The results highlight the need for acceptancy and ongoing checks of protective aprons to ensure that radiation exposure of imaging personnel is kept to a minimum. (orig.)

  3. On the equivalence of chaos control systems

    International Nuclear Information System (INIS)

    Wang Xiaofan

    2003-01-01

    For a given chaotic system, different control systems can be constructed depending on which parameter is tuned or where the external input is added. We prove that two different feedback control systems are qualitatively equivalent if they are feedback linearizable

  4. Confluence Modulo Equivalence in Constraint Handling Rules

    DEFF Research Database (Denmark)

    Christiansen, Henning; Kirkeby, Maja Hanne

    2015-01-01

    Previous results on confluence for Constraint Handling Rules, CHR, are generalized to take into account user-defined state equivalence relations. This allows a much larger class of programs to enjoy the advantages of confluence, which include various optimization techniques and simplified...

  5. Human Factor in Therapeutic Relationship

    Directory of Open Access Journals (Sweden)

    Ramazan Akdogan

    2011-03-01

    Full Text Available herapeutic relationship is a professional relationship that has been structured based on theoretical props. This relationship is a complicated, wide and unique relationship which develops between two people, where both sides' personality and attitudes inevitably interfere. Therapist-client relationship experienced through transference and counter transference, especially in psychodynamic approaches, is accepted as the main aspect of therapeutic process. However, the approaches without dynamic/deterministic tendency also take therapist-client relationship into account seriously and stress uniqueness of interaction between two people. Being a person and a human naturally sometimes may negatively influence the relationship between the therapist and client and result in a relationship going out of the theoretical frame at times. As effective components of a therapeutic process, the factors that stem from being human include the unique personalities of the therapist and the client, their values and their attitude either made consciously or subconsciously. Literature has shown that the human-related factors are too effective to be denied in therapeutic relationship process. Ethical and theoretical knowledge can be inefficient to prevent the negative effects of these factors in therapeutic process at which point a deep insight and supervision would have a critical role in continuing an acceptable therapeutic relationship. This review is focused on the reflection of some therapeutic factors resulting from being human and development of counter transference onto the therapeutic process.

  6. Therapeutic monoclonal antibody N-glycosylation - Structure, function and therapeutic potential.

    Science.gov (United States)

    Cymer, Florian; Beck, Hermann; Rohde, Adelheid; Reusch, Dietmar

    2018-03-01

    Therapeutic antibodies (IgG-type) contain several post-translational modifications (PTMs) whereby introducing a large heterogeneity, both structural and functional, into this class of therapeutics. Of these modifications, glycosylation in the fragment crystallizable (Fc) region is the most heterogeneous PTM, which can affect the stability of the molecule and interactions with Fc-receptors in vivo. Hence, the glycoform distribution can affect the mode of action and have implications for bioactivity, safety and efficacy of the drug. Main topics of the manuscript include: What factors influence the (Fc) glycan pattern in therapeutic antibodies and how can these glycans be characterized? How does structure of the Fc-glycan relate to function and what methods are available to characterize those functions? Although heterogeneous in their scope, the different sections are intended to combine current knowledge on structure-function correlations of IgG glycan structures with regard to Fc (effector) functions, as well as basic aspects and methodologies for their assessment. Copyright © 2017. Published by Elsevier Ltd.

  7. Translational nanomedicine--through the therapeutic window.

    Science.gov (United States)

    Pierce, Robin L

    2015-01-01

    Translational nanomedicine occurs only through the successful integration of multiple inputs and iterative modifications. The therapeutic window plays a pivotal role in the trajectory of translational nanomedicine. Often defined in terms of the range of dosage for safe and effective therapeutic effect, a second definition of the therapeutic window refers to the often narrow temporal window in which a therapeutic effect can be obtained. Expanding the second definition to explicitly include the spatial dimension, this article explores aspects of the therapeutic spaces created by nanomedicine that shift the traditional dimensions of symptom, sign and pathology. This article analyzes three aspects of the therapeutic window in nanomedicine - temporal, spatial and manner of construction and their impact on the dimensions of modern medicine.

  8. Neutron dosimetry using proportional counters with tissue equivalent walls

    International Nuclear Information System (INIS)

    Kerviller, H. de

    1965-01-01

    The author reminds the calculation method of the neutron absorbed dose in a material and deduce of it the conditions what this material have to fill to be equivalent to biological tissues. Various proportional counters are mode with walls in new tissue equivalent material and filled with various gases. The multiplication factor and neutron energy response of these counters are investigated and compared with those obtained with ethylene lined polyethylene counters. The conditions of working of such proportional counters for neutron dosimetry in energy range 10 -2 to 15 MeV are specified. (author) [fr

  9. A weak equivalence principle test on a suborbital rocket

    Energy Technology Data Exchange (ETDEWEB)

    Reasenberg, Robert D; Phillips, James D, E-mail: reasenberg@cfa.harvard.ed [Smithsonian Astrophysical Observatory, Harvard-Smithsonian Center for Astrophysics, Cambridge, MA 02138 (United States)

    2010-05-07

    We describe a Galilean test of the weak equivalence principle, to be conducted during the free fall portion of a sounding rocket flight. The test of a single pair of substances is aimed at a measurement uncertainty of sigma(eta) < 10{sup -16} after averaging the results of eight separate drops. The weak equivalence principle measurement is made with a set of four laser gauges that are expected to achieve 0.1 pm Hz{sup -1/2}. The discovery of a violation (eta not = 0) would have profound implications for physics, astrophysics and cosmology.

  10. Two dimensional analysis of MHD generator by means of equivalent circuit

    International Nuclear Information System (INIS)

    Yoshida, Masaharu; Umoto, Juro

    1975-01-01

    The authors report on the method analyzing generally the MHD generator by means of the equivalent circuit including the negative resistance. At first, they divide the duct space into many space elements, and for each space element they derive the fundamental equivalent four-terminal circuit which satisfies the two-dimensional Ohm's law. Next, they make an attempt to apply the equivalent circuits to the typical MHD generators such as diagonal, Faraday and Hall generators considering the boundary layer in the duct and the wall leakage current. Using their analysis, the current density, Joul's heat, generated and output electrical powers, electrical efficiency etc. in the generator can be fairly easily calculated. (auth.)

  11. Approximating Behavioral Equivalence of Models Using Top-K Policy Paths

    DEFF Research Database (Denmark)

    Zeng, Yifeng; Chen, Yingke; Prashant, Doshi

    2011-01-01

    Decision making and game play in multiagent settings must often contend with behavioral models of other agents in order to predict their actions. One approach that reduces the complexity of the unconstrained model space is to group models that tend to be behaviorally equivalent. In this paper, we...... seek to further compress the model space by introducing an approximate measure of behavioral equivalence and using it to group models....

  12. Therapeutic enhancement: nursing intervention category for patients diagnosed with Readiness for Therapeutic Regimen Management.

    Science.gov (United States)

    Kelly, Cynthia W

    2008-04-01

    To present a new nursing intervention category called therapeutic enhancement. Fewer than half of North Americans follow their physician's recommendations for diet and exercise, even when such are crucial to their health or recovery. It is imperative that nurses consider new ways to promote healthy behaviours. Therapeutic enhancement is intended to provide such a fresh approach. Traditional intervention techniques focusing on education, contracts, social support and more frequent interaction with physicians appear not to be effective when used alone. Successful strategies have been multidisciplinary; and have included interventions by professional nurses who assist patients to understand their disease and the disease process and that helps them to develop disease-management and self-management skills. Therapeutic enhancement incorporates The Stages of Change Theory, Commitment to Health Theory, Motivational Interviewing techniques and instrumentation specifically designed for process evaluation of health-promoting interventions. This is a critical review of approaches that, heretofore, have not been synthesised in a single published article. Based on the commonly used Stages of Change model, therapeutic enhancement is useful for patients who are at the action stage of change. Using therapeutic enhancement as well as therapeutic strategies identified in Stages of Change Theory, such as contingency management, helping relationships, counterconditioning, stimulus control and Motivational Interviewing techniques, nursing professionals can significantly increase the chances of patients moving from action to the maintenance stage of change for a specific health behaviour. Using the nursing intervention category, therapeutic enhancement can increase caregivers' success in helping patients maintain healthy behaviours.

  13. The therapeutic relationship after psychiatric admission.

    LENUS (Irish Health Repository)

    Roche, Eric

    2014-03-01

    The therapeutic relationship is one of the most central and important factors in the treatment of mental health disorders. A better therapeutic relationship is associated with service engagement, medication adherence, and satisfaction with services. This study aimed to compare the demographic and clinical factors associated with the therapeutic relationship in voluntarily and involuntarily admitted psychiatric service users. We found that individuals who had been admitted involuntarily, who had a diagnosis of a psychotic disorder, and who reported higher levels of perceived pressures on admission were more likely to have a poorer therapeutic relationship with their consultant psychiatrist. Greater levels of insight and treatment satisfaction, together with higher levels of procedural justice experienced on admission, were associated with a better therapeutic relationship. We found that the level of perceived coercion on admission was not related to the therapeutic relationship. Targeted interventions to improve the therapeutic relationship, particularly for involuntarily admitted service users, are discussed.

  14. Quality factor and dose equivalent investigations aboard the Soviet Space Station Mir

    Science.gov (United States)

    Bouisset, P.; Nguyen, V. D.; Parmentier, N.; Akatov, Ia. A.; Arkhangel'Skii, V. V.; Vorozhtsov, A. S.; Petrov, V. M.; Kovalev, E. E.; Siegrist, M.

    1992-07-01

    Since Dec 1988, date of the French-Soviet joint space mission 'ARAGATZ', the CIRCE device, had recorded dose equivalent and quality factor values inside the Mir station (380-410 km, 51.5 deg). After the initial gas filling two years ago, the low pressure tissue equivalent proportional counter is still in good working conditions. Some results of three periods are presented. The average dose equivalent rates measured are respectively 0.6, 0.8 and 0.6 mSv/day with a quality factor equal to 1.9. Some detailed measurements show the increasing of the dose equivalent rates through the SAA and near polar horns. The real time determination of the quality factors allows to point out high linear energy transfer events with quality factors in the range 10-20.

  15. Energetical and multiscale approaches for the definition of an equivalent stress for magneto-elastic couplings

    International Nuclear Information System (INIS)

    Hubert, Olivier; Daniel, Laurent

    2011-01-01

    A main limitation of most models describing the effect of stress on the magnetic behavior is that they are restricted to uniaxial - tensile or compressive - stress. Nevertheless, stress is multiaxial in most of industrial applications. An idea to overcome the strong limitation of models is to define a fictive uniaxial stress, the equivalent stress, that would change the magnetic behavior in a similar manner than a multiaxial stress. A first definition of equivalent stress, called the deviatoric equivalent stress, is proposed. It is based on an equivalence in magneto-elastic energy. This formulation is first derived for isotropic materials under specific assumptions. An extension to orthotropic media under disoriented magneto-mechanical loading is made. A new equivalent stress expression, called generalized equivalent stress, is then proposed. It is based on an equivalence in magnetization. Inverse identification of equivalent stress is made possible thanks to a strong simplification of the description of the material seen as an assembly of elementary magnetic domains. It is shown that this second proposal is a generalization of the deviatoric expression. Equivalent stress proposals are compared to former proposals and validated using experimental results carried out on an iron-cobalt sheet submitted to biaxial mechanical loading. These results are compared to the predictions obtained thanks to the equivalent stress formulations. The generalized equivalent stress is shown to be a tool able to foresee the magnetic behavior of a large panel of materials submitted to multiaxial stress. - Research highlights: → Classical magneto-elastic models restricted to uniaxial stress. → Stress demonstrated multiaxial in most of industrial applications. → Proposals of deviatoric and generalized equivalent stresses - multidomain modeling. → Experimental validation using iron-cobalt sheet submitted to biaxial loading. → Generalization of former proposals and modeling of

  16. Electro-optical equivalent calibration technology for high-energy laser energy meters

    Energy Technology Data Exchange (ETDEWEB)

    Wei, Ji Feng, E-mail: wjfcom2000@163.com [State Key Laboratory of Precision Measurement Technology and Instrument, Tsinghua University, Beijing 100084 (China); Institute of Applied Electronics, China Academy of Engineering Physics, Mianyang 621900 (China); Graduate School of China Academy of Engineering Physics, Beijing 100088 (China); Key Laboratory of Laser Science and Technology, China Academy of Engineering Physics, Mianyang 621900 (China); Chang, Yan; Zhang, Kai; Hu, Xiao Yang; Zhang, Wei [Institute of Applied Electronics, China Academy of Engineering Physics, Mianyang 621900 (China); Key Laboratory of Laser Science and Technology, China Academy of Engineering Physics, Mianyang 621900 (China); Sun, Li Qun [State Key Laboratory of Precision Measurement Technology and Instrument, Tsinghua University, Beijing 100084 (China)

    2016-04-15

    Electro-optical equivalent calibration with high calibration power and high equivalence is particularly well-suited to the calibration of high-energy laser energy meters. A large amount of energy is reserved during this process, however, which continues to radiate after power-off. This study measured the radiation efficiency of a halogen tungsten lamp during power-on and after power-off in order to calculate the total energy irradiated by a lamp until the high-energy laser energy meter reaches thermal equilibrium. A calibration system was designed based on the measurement results, and the calibration equivalence of the system was analyzed in detail. Results show that measurement precision is significantly affected by the absorption factor of the absorption chamber and by heat loss in the energy meter. Calibration precision is successfully improved by enhancing the equivalent power and reducing power-on time. The electro-optical equivalent calibration system, measurement uncertainty of which was evaluated as 2.4% (k = 2), was used to calibrate a graphite-cone-absorption-cavity absolute energy meter, yielding a calibration coefficient of 1.009 and measurement uncertainty of 3.5% (k = 2). A water-absorption-type high-energy laser energy meter with measurement uncertainty of 4.8% (k = 2) was considered the reference standard, and compared to the energy meter calibrated in this study, yielded a correction factor of 0.995 (standard deviation of 1.4%).

  17. Deconstructing Equivalence in the Translation of Texts from French to Indonesian

    Directory of Open Access Journals (Sweden)

    Sajarwa Sajarwa

    2017-06-01

    Full Text Available Translation is a process of reproducing a source text (ST in the equivalent target text (TT. The equivalence of translation includes the message of the text. Several factors such as writer, translator, publisher, reader, or spirit of certain era, determine the translation equivalency. In translation, equivalence is negotiated and transactioned; in consequence it is highly likely that the current equivalency will be different in the future. Deconstruction theory claims that the relationship between a signifier and a signified is inconstant; however, it can be “deferred” to obtain a new or different relationship. As a result, a meaning may change in accordance with the will of its user. The result of this research indicates four differences between TT1 and TT2 translation; (1 within a period of twenty years of social and political change (1990 – 2010, TT1 reveals regional issues, while TT2 reveals social class issues; (2 the TT2’s disclosure of meaning is more direct, open, and occasionally rude than the subtle and euphemistic TT1; (3 the TT2 tends to follow ideology of foreignization by inserting foreign words or words from the source language, while the TT1 tends to follow ideology of domestication; (4 there are different viewpoints between the TT1 translator and the TT2 translator.

  18. Therapeutic Engagement as a Predictor of Retention in Adolescent Therapeutic Community Treatment

    Science.gov (United States)

    Abdel-Salam, Sami; Gunter, Whitney D.

    2014-01-01

    The adolescent drug problem places a huge toll on society and a heavy burden on the criminal justice system. Research regarding the benefits of therapeutic community (TC) treatment for adolescents has shown it to be effective. Despite the ability of therapeutic communities to lower drug relapse and reduce criminality, a great deal remains unknown…

  19. Neutrino oscillations in non-inertial frames and the violation of the equivalence principle neutrino mixing induced by the equivalence principle violation

    International Nuclear Information System (INIS)

    Lambiase, G.

    2001-01-01

    Neutrino oscillations are analyzed in an accelerating and rotating reference frame, assuming that the gravitational coupling of neutrinos is flavor dependent, which implies a violation of the equivalence principle. Unlike the usual studies in which a constant gravitational field is considered, such frames could represent a more suitable framework for testing if a breakdown of the equivalence principle occurs, due to the possibility to modulate the (simulated) gravitational field. The violation of the equivalence principle implies, for the case of a maximal gravitational mixing angle, the presence of an off-diagonal term in the mass matrix. The consequences on the evolution of flavor (mass) eigenstates of such a term are analyzed for solar (oscillations in the vacuum) and atmospheric neutrinos. We calculate the flavor oscillation probability in the non-inertial frame, which does depend on its angular velocity and linear acceleration, as well as on the energy of neutrinos, the mass-squared difference between two mass eigenstates, and on the measure of the degree of violation of the equivalence principle (Δγ). In particular, we find that the energy dependence disappears for vanishing mass-squared difference, unlike the result obtained by Gasperini, Halprin, Leung, and other physical mechanisms proposed as a viable explanation of neutrino oscillations. Estimations on the upper values of Δγ are inferred for a rotating observer (with vanishing linear acceleration) comoving with the earth, hence ω∝7.10 -5 rad/sec, and all other alternative mechanisms generating the oscillation phenomena have been neglected. In this case we find that the constraints on Δγ are given by Δγ≤10 2 for solar neutrinos and Δγ≤10 6 for atmospheric neutrinos. (orig.)

  20. [Health security--GMOs in therapeutics].

    Science.gov (United States)

    Trouvin, J-H

    2003-03-01

    The recent progress in human therapeutics has been made possible thanks to molecular biology and its use in producing proteins having the same sequence and structure as that of human proteins. The use of GMOs allows production of proteins with high added value in therapeutics, which are of satisfactory quality. GMOs may also be directly administered to patients as gene therapy vectors. However, the use of GMOs in therapeutics must take into consideration some risks, particularly those of microbiological contamination, of neo-antigenicity as well as environmental risks with regard to the way of use of the GMO. Nevertheless, those risks are taken in due consideration in the development of these new medicinal products; solutions have been found to allow their use in therapeutics with a very positive benefit/risk ratio. Medicinal products from biotechnology have enabled considerable therapeutic progress without compromising health security.

  1. Bilingual Dictionaries and Communicative Equivalence for a ...

    African Journals Online (AJOL)

    This implies that a bilingual dictionary becomes a poly functional instrument, presenting more information than just translation equivalents. ... With the emphasis on the user perspective, metalexicographical criteria are used to investigate problems regarding the access structure and the addressing procedures in Afrikaans ...

  2. Confluence Modulo Equivalence in Constraint Handling Rules

    DEFF Research Database (Denmark)

    Christiansen, Henning; Kirkeby, Maja Hanne

    2014-01-01

    Previous results on confluence for Constraint Handling Rules, CHR, are generalized to take into account user-defined state equivalence relations. This allows a much larger class of programs to enjoy the ad- vantages of confluence, which include various optimization techniques and simplified...

  3. From the Neutral Theory to a Comprehensive and Multiscale Theory of Ecological Equivalence.

    Science.gov (United States)

    Munoz, François; Huneman, Philippe

    2016-09-01

    The neutral theory of biodiversity assumes that coexisting organisms are equally able to survive, reproduce, and disperse (ecological equivalence), but predicts that stochastic fluctuations of these abilities drive diversity dynamics. It predicts remarkably well many biodiversity patterns, although substantial evidence for the role of niche variation across organisms seems contradictory. Here, we discuss this apparent paradox by exploring the meaning and implications of ecological equivalence. We address the question whether neutral theory provides an explanation for biodiversity patterns and acknowledges causal processes. We underline that ecological equivalence, although central to neutral theory, can emerge at local and regional scales from niche-based processes through equalizing and stabilizing mechanisms. Such emerging equivalence corresponds to a weak conception of neutral theory, as opposed to the assumption of strict equivalence at the individual level in strong conception. We show that this duality is related to diverging views on hypothesis testing and modeling in ecology. In addition, the stochastic dynamics exposed in neutral theory are pervasive in ecological systems and, rather than a null hypothesis, ecological equivalence is best understood as a parsimonious baseline to address biodiversity dynamics at multiple scales.

  4. Therapeutic cloning: The ethical limits

    International Nuclear Information System (INIS)

    Whittaker, Peter A.

    2005-01-01

    A brief outline of stem cells, stem cell therapy and therapeutic cloning is given. The position of therapeutic cloning with regard to other embryonic manipulations - IVF-based reproduction, embryonic stem formation from IVF embryos and reproductive cloning - is indicated. The main ethically challenging stages in therapeutic cloning are considered to be the nuclear transfer process including the source of eggs for this and the destruction of an embryo to provide stem cells for therapeutic use. The extremely polarised nature of the debate regarding the status of an early human embryo is noted, and some potential alternative strategies for preparing immunocompatible pluripotent stem cells are indicated

  5. Therapeutic cloning in the mouse

    Science.gov (United States)

    Mombaerts, Peter

    2003-01-01

    Nuclear transfer technology can be applied to produce autologous differentiated cells for therapeutic purposes, a concept termed therapeutic cloning. Countless articles have been published on the ethics and politics of human therapeutic cloning, reflecting the high expectations from this new opportunity for rejuvenation of the aging or diseased body. Yet the research literature on therapeutic cloning, strictly speaking, is comprised of only four articles, all in the mouse. The efficiency of derivation of embryonic stem cell lines via nuclear transfer is remarkably consistent among these reports. However, the efficiency is so low that, in its present form, the concept is unlikely to become widespread in clinical practice. PMID:12949262

  6. Cross-Ethnicity Measurement Equivalence of Family Coping for Breast Cancer Survivors

    Science.gov (United States)

    Lim, Jung-won; Townsend, Aloen

    2012-01-01

    Objective: The current study examines the equivalence of a measure of family coping, the Family Crisis Oriented Personal Evaluation scales (F-COPES), in Chinese American and Korean American breast cancer survivors (BCS). Methods: Factor structure and cross-ethnicity equivalence of the F-COPES were tested using structural equation modeling with 157…

  7. The Equivalence of Translated Songs Lyrics and their Effects - The Case of Translated Ecclesial Songs

    Directory of Open Access Journals (Sweden)

    S. Suharto

    2015-01-01

    Full Text Available This study aimed at describing the equivalence of eclessial song lyrics, which belong to the content word, the meaning of the sentences and their effect on church songs. The method used in this study is descriptive and qualitative by using music, language, and interdiciline approach. The data collection method used questionnaires technique, interview, documents and content analysis. The data used are 5 documents of songs chosen purposively as the primary data. Based on the data being analyzed, the results of this study were: 1 The translated content word located in the same bars and equivalent was around 27.07%, the translated content word located in the same bars, but not equivalent was 18.34%, the translated content word located in the different bars, but equivalent was 11.79%, the translated content word located in the different bars and not equivalent was 2.62%, and the untranslated words were 4.17%. 2 The translation of equivalence beautiful lyrics showed the beauty of the song was equivalent at 17.02%, the beauty of the song was less equivalent at 29.78%, the beauty of the song was not equivalent of 61.70%. 3. The differences of structure caused the incorrect dictions or choice of words and missing words in the translated lyrics.

  8. The equivalent energy method: an engineering approach to fracture

    International Nuclear Information System (INIS)

    Witt, F.J.

    1981-01-01

    The equivalent energy method for elastic-plastic fracture evaluations was developed around 1970 for determining realistic engineering estimates for the maximum load-displacement or stress-strain conditions for fracture of flawed structures. The basis principles were summarized but the supporting experimental data, most of which were obtained after the method was proposed, have never been collated. This paper restates the original bases more explicitly and presents the validating data in graphical form. Extensive references are given. The volumetric energy ratio, a modelling parameter encompassing both size and temperature, is the fundamental parameter of the equivalent energy method. It is demonstrated that, in an engineering sense, the volumetric energy ratio is a unique material characteristic for a steel, much like a material property except size must be taken into account. With this as a proposition, the basic formula of the equivalent energy method is derived. Sufficient information is presented so that investigators and analysts may judge the viability and applicability of the method to their areas of interest. (author)

  9. The Paramyxovirus Polymerase Complex as a Target for Next-Generation Anti-Paramyxovirus Therapeutics

    Directory of Open Access Journals (Sweden)

    Richard K Plemper

    2015-05-01

    Full Text Available The paramyxovirus family includes major human and animal pathogens, including measles virus, mumps virus, and human respiratory syncytial virus (RSV, as well as the emerging zoonotic Hendra and Nipah viruses. In the United States, RSV is the leading cause of infant hospitalizations due to viral infectious disease. Despite their clinical significance, effective drugs for the improved management of paramyxovirus disease are lacking. The development of novel anti-paramyxovirus therapeutics is therefore urgently needed. Paramyxoviruses contain RNA genomes of negative polarity, necessitating a virus-encoded RNA-dependent RNA polymerase (RdRp complex for replication and transcription. Since an equivalent enzymatic activity is absent in host cells, the RdRp complex represents an attractive druggable target, although structure-guided drug development campaigns are hampered by the lack of high-resolution RdRp crystal structures. Here, we review the current structural and functional insight into the paramyxovirus polymerase complex in conjunction with an evaluation of the mechanism of activity and developmental status of available experimental RdRp inhibitors. Our assessment spotlights the importance of the RdRp complex as a premier target for therapeutic intervention and examines how high-resolution insight into the organization of the complex will pave the path towards the structure-guided design and optimization of much-needed next-generation paramyxovirus RdRp blockers.

  10. The development of BH3105E type neutron dose-equivalent meter

    International Nuclear Information System (INIS)

    Ji Changsong; Wang Tingting; Zhang Shuheng; Tan Baozeng

    2011-01-01

    A new BH3105E Type Neutron Dose-equivalent Meter has been developed. The 'multi-stick' ab- sorption method is used for thermal -14 MeV neutron equal dose-equivalent detection, what gives a high neutron sensitivity of 5 cps/μSv · h-1. RS-232 interface is accepted for signal communication (authors)

  11. On the equivalence of the Clauser–Horne and Eberhard inequality based tests

    International Nuclear Information System (INIS)

    Khrennikov, Andrei; Ramelow, Sven; Ursin, Rupert; Wittmann, Bernhard; Kofler, Johannes; Basieva, Irina

    2014-01-01

    Recently, the results of the first experimental test for entangled photons closing the detection loophole (also referred to as the fair sampling loophole) were published (Vienna, 2013). From the theoretical viewpoint the main distinguishing feature of this long-aspired to experiment was that the Eberhard inequality was used. Almost simultaneously another experiment closing this loophole was performed (Urbana-Champaign, 2013) and it was based on the Clauser–Horne inequality (for probabilities). The aim of this note is to analyze the mathematical and experimental equivalence of tests based on the Eberhard inequality and various forms of the Clauser–Horne inequality. The structure of the mathematical equivalence is nontrivial. In particular, it is necessary to distinguish between algebraic and statistical equivalence. Although the tests based on these inequalities are algebraically equivalent, they need not be equivalent statistically, i.e., theoretically the level of statistical significance can drop under transition from one test to another (at least for finite samples). Nevertheless, the data collected in the Vienna test implies not only a statistically significant violation of the Eberhard inequality, but also of the Clauser–Horne inequality (in the ratio-rate form): for both a violation >60σ. (paper)

  12. Estimation of Toxicity Equivalent Concentration (TEQ) of ...

    African Journals Online (AJOL)

    Estimation of Toxicity Equivalent Concentration (TEQ) of carcinogenic polycyclic aromatic hydrocarbons in soils from Idu Ekpeye playground and University of Port ... Effective soil remediation and detoxification method like Dispersion by chemical reaction technology should be deployed to clean-up sites to avoid soil toxicity ...

  13. Violation of Equivalence Principle and Solar Neutrinos

    International Nuclear Information System (INIS)

    Gago, A.M.; Nunokawa, H.; Zukanovich Funchal, R.

    2001-01-01

    We have updated the analysis for the solution to the solar neutrino problem by the long-wavelength neutrino oscillations induced by a tiny breakdown of the weak equivalence principle of general relativity, and obtained a very good fit to all the solar neutrino data

  14. Impact velocity vs. target hardness relationships for equivalent response of cask structures

    International Nuclear Information System (INIS)

    Chen, T.F.; Chen, J.C.; Witte, M.C.; Fischer, L.E.

    1993-01-01

    In this paper, impact velocity vs. target hardness relationships for cask structures are reviewed. The relationships are based on equivalent cask responses in terms of equal deceleration or similar cask damages. By examining several past cask or container tests as well as some analytical results, some conclusions can be drawn about the relationship between target hardness and equivalent impact velocities. This relationship clearly shows that the cask response to impact is cask-dependent and that the rigid sphere impact model results in an unconservative estimate of equivalent velocity

  15. Assessment of organ equivalent doses and effective doses from diagnostic X-ray examinations

    International Nuclear Information System (INIS)

    Park, Sang Hyun

    2003-02-01

    The MIRD-type adult male, female and age 10 phantoms were constructed to evaluate organ equivalent dose and effective dose of patient due to typical diagnostic X-ray examination. These phantoms were constructed with external and internal dimensions of Korean. The X-ray energy spectra were generated with SPEC78. MCNP4B ,the general-purposed Monte Carlo code, was used. Information of chest PA , chest LAT, and abdomen AP diagnostic X-ray procedures was collected on the protocol of domestic hospitals. The results showed that patients pick up approximate 0.02 to 0.18 mSv of effective dose from a single chest PA examination, and 0.01 to 0.19 mSv from a chest LAT examination depending on the ages. From an abdomen AP examination, patients pick up 0.17 to 1.40 mSv of effective dose. Exposure time, organ depth from the entrance surface and X-ray beam field coverage considerably affect the resulting doses. Deviation among medical institutions is somewhat high, and this indicated that medical institutions should interchange their information and the need of education for medical staff. The methodology and the established system can be applied, with some expansion, to dose assessment for other medical procedures accompanying radiation exposure of patients like nuclear medicine or therapeutic radiology

  16. Development of a neutron personal dose equivalent detector

    International Nuclear Information System (INIS)

    Tsujimura, N.; Yoshida, T.; Takada, C.; Momose, T.; Nunomiya, T.; Aoyama, K.

    2007-01-01

    A new neutron-measuring instrument that is intended to measure a neutron personal dose equivalent, H p (10) was developed. This instrument is composed of two parts: (1) a conventional moderator-based neutron dose equivalent meter and (2) a neutron shield made of borated polyethylene, which covers a backward hemisphere to adjust the angular dependence. The whole design was determined on the basis of MCNP calculations so as to have response characteristics that would generally match both the energy and angular dependencies of H p (10). This new instrument will be a great help in assessing the reference values of neutron H p (10) during field testing of personal neutron dosemeters in workplaces and also in interpreting their readings. (authors)

  17. Composition variability and equivalence of Shonka TE plastic

    International Nuclear Information System (INIS)

    Spokas, J.J.

    1973-01-01

    A number of conducting plastic mixtures had been developed by Francis R. Shonka, and collaborators, in the Physical Sciences Laboratory of Illinois Benedictine College (formerly St. Procopius College). Several of these mixtures have been used widely in radiation research. In particular, a tissue-equivalent (muscle) formulation designated A-150 has been used extensively in the dosimetry, research and measurements of gamma, neutron and pion beams. Certain confusion has arisen concerning the composition of A-150. The definition of A-150 is reviewed and what is known of the composition is summarized. The equivalence of A-150 and ICRU ''muscle'' with respect to photons is discussed as a function of photon energy using the latest data on extra-nuclear photon cross sections. (U.S.)

  18. An Equivalent cross-section Framework for improving computational efficiency in Distributed Hydrologic Modelling

    Science.gov (United States)

    Khan, Urooj; Tuteja, Narendra; Ajami, Hoori; Sharma, Ashish

    2014-05-01

    While the potential uses and benefits of distributed catchment simulation models is undeniable, their practical usage is often hindered by the computational resources they demand. To reduce the computational time/effort in distributed hydrological modelling, a new approach of modelling over an equivalent cross-section is investigated where topographical and physiographic properties of first-order sub-basins are aggregated to constitute modelling elements. To formulate an equivalent cross-section, a homogenization test is conducted to assess the loss in accuracy when averaging topographic and physiographic variables, i.e. length, slope, soil depth and soil type. The homogenization test indicates that the accuracy lost in weighting the soil type is greatest, therefore it needs to be weighted in a systematic manner to formulate equivalent cross-sections. If the soil type remains the same within the sub-basin, a single equivalent cross-section is formulated for the entire sub-basin. If the soil type follows a specific pattern, i.e. different soil types near the centre of the river, middle of hillslope and ridge line, three equivalent cross-sections (left bank, right bank and head water) are required. If the soil types are complex and do not follow any specific pattern, multiple equivalent cross-sections are required based on the number of soil types. The equivalent cross-sections are formulated for a series of first order sub-basins by implementing different weighting methods of topographic and physiographic variables of landforms within the entire or part of a hillslope. The formulated equivalent cross-sections are then simulated using a 2-dimensional, Richards' equation based distributed hydrological model. The simulated fluxes are multiplied by the weighted area of each equivalent cross-section to calculate the total fluxes from the sub-basins. The simulated fluxes include horizontal flow, transpiration, soil evaporation, deep drainage and soil moisture. To assess

  19. Evaluation of pharmaceutical and chemical equivalence of selected ...

    African Journals Online (AJOL)

    Personal

    Evaluation of Pharmaceutical and Chemical Equivalence of Selected Brands of Diclofenac Sodium .... strength- friability. /disintegration time ratio. (CSFR/DT). Drug content. % w/w ... Table 3: Parameters obtained from Kitazawa analysis. Brand.

  20. Electrothermal Equivalent Three-Dimensional Finite-Element Model of a Single Neuron.

    Science.gov (United States)

    Cinelli, Ilaria; Destrade, Michel; Duffy, Maeve; McHugh, Peter

    2018-06-01

    We propose a novel approach for modelling the interdependence of electrical and mechanical phenomena in nervous cells, by using electrothermal equivalences in finite element (FE) analysis so that existing thermomechanical tools can be applied. First, the equivalence between electrical and thermal properties of the nerve materials is established, and results of a pure heat conduction analysis performed in Abaqus CAE Software 6.13-3 are validated with analytical solutions for a range of steady and transient conditions. This validation includes the definition of equivalent active membrane properties that enable prediction of the action potential. Then, as a step toward fully coupled models, electromechanical coupling is implemented through the definition of equivalent piezoelectric properties of the nerve membrane using the thermal expansion coefficient, enabling prediction of the mechanical response of the nerve to the action potential. Results of the coupled electromechanical model are validated with previously published experimental results of deformation for squid giant axon, crab nerve fibre, and garfish olfactory nerve fibre. A simplified coupled electromechanical modelling approach is established through an electrothermal equivalent FE model of a nervous cell for biomedical applications. One of the key findings is the mechanical characterization of the neural activity in a coupled electromechanical domain, which provides insights into the electromechanical behaviour of nervous cells, such as thinning of the membrane. This is a first step toward modelling three-dimensional electromechanical alteration induced by trauma at nerve bundle, tissue, and organ levels.

  1. Gap sequence, Lipschitz equivalence and box dimension of fractal sets

    International Nuclear Information System (INIS)

    Rao Hui; Yang Yamin; Ruan Huojun

    2008-01-01

    We introduce a notion of gap sequences for compact sets E subset of R d , which is a generalization of the gap sequences of compact sets on the real line. We show that if the gap sequences of two fractal sets are not equivalent, then these two sets cannot be Lipschitz equivalent, where the latter fact is usually very hard to verify. Finally, we show that for some typical fractal sets, the gap sequences characterize the upper box dimension

  2. Modified methods for growing 3-D skin equivalents: an update.

    Science.gov (United States)

    Lamb, Rebecca; Ambler, Carrie A

    2014-01-01

    Artificial epidermis can be reconstituted in vitro by seeding primary epidermal cells (keratinocytes) onto a supportive substrate and then growing the developing skin equivalent at the air-liquid interface. In vitro skin models are widely used to study skin biology and for industrial drug and cosmetic testing. Here, we describe updated methods for growing 3-dimensional skin equivalents using de-vitalized, de-epidermalized dermis (DED) substrates including methods for DED substrate preparation, cell seeding, growth conditions, and fixation procedures.

  3. A Model for Semantic Equivalence Discovery for Harmonizing Master Data

    Science.gov (United States)

    Piprani, Baba

    IT projects often face the challenge of harmonizing metadata and data so as to have a "single" version of the truth. Determining equivalency of multiple data instances against the given type, or set of types, is mandatory in establishing master data legitimacy in a data set that contains multiple incarnations of instances belonging to the same semantic data record . The results of a real-life application define how measuring criteria and equivalence path determination were established via a set of "probes" in conjunction with a score-card approach. There is a need for a suite of supporting models to help determine master data equivalency towards entity resolution—including mapping models, transform models, selection models, match models, an audit and control model, a scorecard model, a rating model. An ORM schema defines the set of supporting models along with their incarnation into an attribute based model as implemented in an RDBMS.

  4. Study of the equivalent diameter concept for heat transfer by forced convection in annular channels

    International Nuclear Information System (INIS)

    Mendez T, D.

    1994-01-01

    This work describes a comparative analysis between experimental values of heat transfer coefficients in fully developed turbulent flow for a concentric annular channel, and those calculated with the empirical correlations obtained for tubes by Dittus-Boelter, Sieder and Tate, a modified Colburn equation, and that proposed by Gnielinski which applies the analogy between friction and heat transfer. The coefficients were calculated by means of two different equivalent diameters: 1) The hydraulic equivalent diameter; and 2) The heated equivalent diameter. It was concluded that the hydraulic equivalent diameter gives much better results than the heated equivalent diameter. (Author)

  5. Achieving the Promise of Therapeutic Extracellular Vesicles: The Devil is in Details of Therapeutic Loading.

    Science.gov (United States)

    Sutaria, Dhruvitkumar S; Badawi, Mohamed; Phelps, Mitch A; Schmittgen, Thomas D

    2017-05-01

    Extracellular vesicles (EVs) represent a class of cell secreted organelles which naturally contain biomolecular cargo such as miRNA, mRNA and proteins. EVs mediate intercellular communication, enabling the transfer of functional nucleic acids from the cell of origin to the recipient cells. In addition, EVs make an attractive delivery vehicle for therapeutics owing to their increased stability in circulation, biocompatibility, low immunogenicity and toxicity profiles. EVs can also be engineered to display targeting moieties on their surfaces which enables targeting to desired tissues, organs or cells. While much has been learned on the role of EVs as cell communicators, the field of therapeutic EV application is currently under development. Critical to the future success of EV delivery system is the description of methods by which therapeutics can be successfully and efficiently loaded within the EVs. Two methods of loading of EVs with therapeutic cargo exist, endogenous and exogenous loading. We have therefore focused this review on describing the various published approaches for loading EVs with therapeutics.

  6. Equivalent Method of Solving Quantum Efficiency of Reflection-Mode Exponential Doping GaAs Photocathode

    International Nuclear Information System (INIS)

    Jun, Niu; Zhi, Yang; Ben-Kang, Chang

    2009-01-01

    The mathematical expression of the electron diffusion and drift length L DE of exponential doping photocathode is deduced. In the quantum efficiency equation of the reffection-mode uniform doping cathode, substituting L DE for L D , the equivalent quantum efficiency equation of the reffection-mode exponential doping cathode is obtained. By using the equivalent equation, theoretical simulation and experimental analysis shows that the equivalent index formula and formula-doped cathode quantum efficiency results in line. The equivalent equation avoids complicated calculation, thereby simplifies the process of solving the quantum efficiency of exponential doping photocathode

  7. Efficient tests for equivalence of hidden Markov processes and quantum random walks

    NARCIS (Netherlands)

    U. Faigle; A. Schönhuth (Alexander)

    2011-01-01

    htmlabstractWhile two hidden Markov process (HMP) resp.~quantum random walk (QRW) parametrizations can differ from one another, the stochastic processes arising from them can be equivalent. Here a polynomial-time algorithm is presented which can determine equivalence of two HMP parametrizations

  8. Einstein's equivalence principle instead of the inertia forces

    International Nuclear Information System (INIS)

    Herreros Mateos, F.

    1997-01-01

    In this article I intend to show that Einstein's equivalence principle substitutes advantageously the inertia forces in the study and resolution of problems in which non-inertial systems appear. (Author) 13 refs

  9. Assessment of Effective Dose Equivalent of Indoor 222Rn Daughters in Inchass

    International Nuclear Information System (INIS)

    Ali, E.M.; Taha, T.M.; Gomaa, M.A.; El-Hussein, A.M.; Ahmad, A.A.

    2000-01-01

    The dominant component of natural radiation dose for the general population comes from the radon gas 222 Rn and its short-lived decay products, Ra A ( 214 Po), Ra B ( 214 Pb), Ra C ( 214 Bi), Ra C( 214 Po) in the breathing air. The objective of the present work is to assess the affective dose equivalent of the inhalation exposure of indoor 222 Rn for occupational workers. Average indon concentrations (Bqm -3 ) were monitored in several departments in Nuclear Research Center by radon monitor. We have calculated the lung dose equivalent and the effective dose equivalent for the Egyptian workers due to inhalation exposure of an equilibrium equivalent concentrations of radon daughters which varies from 0.27 to 2.5 mSvy -1 and 0.016 to 0.152mSvy -1 respectively. The annual effective doses obtained are within the accepted range of ICRP recommendations

  10. Relationship between equivalent chromium content and irradiation-induced swelling in 316 stainless steel

    International Nuclear Information System (INIS)

    Bates, J.F.; Guthrie, G.L.

    1974-12-01

    A correlation is noted between equivalent chromium content and resistance to irradiation induced swelling in various 316 stainless steel specimens which have slightly different chemical compositions. Several examples are cited where an increased concentration of an α-stabilizing minor constituent results in decreased swelling. It is shown that the relative swelling resistance of alloys having the same carbon and equivalent nickel contents is higher for those alloys with the higher equivalent chromium content

  11. Cosmological equivalence principle and the weak-field limit

    International Nuclear Information System (INIS)

    Wiltshire, David L.

    2008-01-01

    The strong equivalence principle is extended in application to averaged dynamical fields in cosmology to include the role of the average density in the determination of inertial frames. The resulting cosmological equivalence principle is applied to the problem of synchronization of clocks in the observed universe. Once density perturbations grow to give density contrasts of order 1 on scales of tens of megaparsecs, the integrated deceleration of the local background regions of voids relative to galaxies must be accounted for in the relative synchronization of clocks of ideal observers who measure an isotropic cosmic microwave background. The relative deceleration of the background can be expected to represent a scale in which weak-field Newtonian dynamics should be modified to account for dynamical gradients in the Ricci scalar curvature of space. This acceleration scale is estimated using the best-fit nonlinear bubble model of the universe with backreaction. At redshifts z -10 ms -2 , is small, when integrated over the lifetime of the universe it amounts to an accumulated relative difference of 38% in the rate of average clocks in galaxies as compared to volume-average clocks in the emptiness of voids. A number of foundational aspects of the cosmological equivalence principle are also discussed, including its relation to Mach's principle, the Weyl curvature hypothesis, and the initial conditions of the universe.

  12. Motor equivalence and structure of variance: multi-muscle postural synergies in Parkinson's disease.

    Science.gov (United States)

    Falaki, Ali; Huang, Xuemei; Lewis, Mechelle M; Latash, Mark L

    2017-07-01

    We explored posture-stabilizing multi-muscle synergies with two methods of analysis of multi-element, abundant systems: (1) Analysis of inter-cycle variance; and (2) Analysis of motor equivalence, both quantified within the framework of the uncontrolled manifold (UCM) hypothesis. Data collected in two earlier studies of patients with Parkinson's disease (PD) were re-analyzed. One study compared synergies in the space of muscle modes (muscle groups with parallel scaling of activation) during tasks performed by early-stage PD patients and controls. The other study explored the effects of dopaminergic medication on multi-muscle-mode synergies. Inter-cycle variance and absolute magnitude of the center of pressure displacement across consecutive cycles were quantified during voluntary whole-body sway within the UCM and orthogonal to the UCM space. The patients showed smaller indices of variance within the UCM and motor equivalence compared to controls. The indices were also smaller in the off-drug compared to on-drug condition. There were strong across-subject correlations between the inter-cycle variance within/orthogonal to the UCM and motor equivalent/non-motor equivalent displacements. This study has shown that, at least for cyclical tasks, analysis of variance and analysis of motor equivalence lead to metrics of stability that correlate with each other and show similar effects of disease and medication. These results show, for the first time, intimate links between indices of variance and motor equivalence. They suggest that analysis of motor equivalence, which requires only a handful of trials, could be used broadly in the field of motor disorders to analyze problems with action stability.

  13. Reactor-produced therapeutic radioisotopes

    International Nuclear Information System (INIS)

    Knapp, F.F. Jr.

    2002-01-01

    The significant worldwide increase in therapeutic radioisotope applications in nuclear medicine, oncology and interventional cardiology requires the dependable production of sufficient levels of radioisotopes for these applications (Reba, 2000; J. Nucl. Med., 1998; Nuclear News, 1999; Adelstein and Manning, 1994). The issues associated with both accelerator- and reactor-production of therapeutic radioisotopes is important. Clinical applications of therapeutic radioisotopes include the use of both sealed sources and unsealed radiopharmaceutical sources. Targeted radiopharmaceutical agents include those for cancer therapy and palliation of bone pain from metastatic disease, ablation of bone marrow prior to stem cell transplantation, treatment modalities for mono and oligo- and polyarthritis, for cancer therapy (including brachytherapy) and for the inhibition of the hyperplastic response following coronary angioplasty and other interventional procedures (For example, see Volkert and Hoffman, 1999). Sealed sources involve the use of radiolabeled devices for cancer therapy (brachytherapy) and also for the inhibition of the hyperplasia which is often encountered after angioplasty, especially with the exponential increase in the use of coronary stents and stents for the peripheral vasculature and other anatomical applications. Since neutron-rich radioisotopes often decay by beta decay or decay to beta-emitting daughter radioisotopes which serve as the basis for radionuclide generator systems, reactors are expected to play an increasingly important role for the production of a large variety of therapeutic radioisotopes required for these and other developing therapeutic applications. Because of the importance of the availability of reactor-produced radioisotopes for these applications, an understanding of the contribution of neutron spectra for radioisotope production and determination of those cross sections which have not yet been established is important. This

  14. High School Equivalency Assessment and Recognition in the United States: An Eyewitness Account

    Science.gov (United States)

    McLendon, Lennox

    2017-01-01

    This chapter on high school equivalency describes recent events involved in updating the adult education high school equivalency assessment services and the entrance of additional assessments into the field.

  15. On experimental testing of the weak equivalence principle for the neutron

    International Nuclear Information System (INIS)

    Pokotilovskij, Yu.N.

    1994-01-01

    The considerations is presented of the experimental situation with the verification of the weak equivalence principle for the neutron. The direct method is proposed to significantly increase (to ∼ 10 -6 ) the precision of the equivalence principle for the neutron in the Galilei type experiment, which uses the thin-film Fabri-Perot interferometer and precise time-of-flight spectrometry of ultracold neutrons

  16. Fuel Cell Equivalent Electric Circuit Parameter Mapping

    DEFF Research Database (Denmark)

    Jeppesen, Christian; Zhou, Fan; Andreasen, Søren Juhl

    In this work a simple model for a fuel cell is investigated for diagnostic purpose. The fuel cell is characterized, with respect to the electrical impedance of the fuel cell at non-faulty conditions and under variations in load current. Based on this the equivalent electrical circuit parameters can...

  17. 43 CFR 426.11 - Class 1 equivalency.

    Science.gov (United States)

    2010-10-01

    ...) Costs of production; (v) Land development costs; (vi) Water quality and adequacy; (vii) Elevation; (viii... equivalency factors by comparing the weighted average farm size required to produce a given level of income on... measured in terms of net income per acre (reflecting both productivity and costs of production). The...

  18. Equivalence Scales for the Former West Germany

    NARCIS (Netherlands)

    Charlier, E.

    1997-01-01

    Equivalence scales provide answers to questions like how much a household with four children needs to spend compared to a household with two children or how much a childless couple needs to spend compared to a single person household to attain the same welfare level. These are important questions

  19. Automatically extracting functionally equivalent proteins from SwissProt

    Directory of Open Access Journals (Sweden)

    Martin Andrew CR

    2008-10-01

    Full Text Available Abstract Background There is a frequent need to obtain sets of functionally equivalent homologous proteins (FEPs from different species. While it is usually the case that orthology implies functional equivalence, this is not always true; therefore datasets of orthologous proteins are not appropriate. The information relevant to extracting FEPs is contained in databanks such as UniProtKB/Swiss-Prot and a manual analysis of these data allow FEPs to be extracted on a one-off basis. However there has been no resource allowing the easy, automatic extraction of groups of FEPs – for example, all instances of protein C. We have developed FOSTA, an automatically generated database of FEPs annotated as having the same function in UniProtKB/Swiss-Prot which can be used for large-scale analysis. The method builds a candidate list of homologues and filters out functionally diverged proteins on the basis of functional annotations using a simple text mining approach. Results Large scale evaluation of our FEP extraction method is difficult as there is no gold-standard dataset against which the method can be benchmarked. However, a manual analysis of five protein families confirmed a high level of performance. A more extensive comparison with two manually verified functional equivalence datasets also demonstrated very good performance. Conclusion In summary, FOSTA provides an automated analysis of annotations in UniProtKB/Swiss-Prot to enable groups of proteins already annotated as functionally equivalent, to be extracted. Our results demonstrate that the vast majority of UniProtKB/Swiss-Prot functional annotations are of high quality, and that FOSTA can interpret annotations successfully. Where FOSTA is not successful, we are able to highlight inconsistencies in UniProtKB/Swiss-Prot annotation. Most of these would have presented equal difficulties for manual interpretation of annotations. We discuss limitations and possible future extensions to FOSTA, and

  20. EXETRA Perspectives: Concepts in Therapeutic Recreation.

    Science.gov (United States)

    Neal, Larry L.; Edginton, Christopher R.

    Fifteen papers address issues in therapeutic recreation for disabled persons from the perspectives of practitioners, educators, and students. The following papers are presented. "Therapeutic Recreation Service: The Past and Challenging Present" (H. Sessoms); "Therapeutic Recreatiion in an Era of Limits: A Crisis...A Challenge... An Opportunity"…

  1. Generation of equivalent forms of operational trans-conductance amplifier-RC sinusoidal oscillators: the nullor approach

    Directory of Open Access Journals (Sweden)

    Raj Senani

    2014-06-01

    Full Text Available It has been shown in two earlier papers published from this study that corresponding to a given single-operational trans-conductance amplifier (single-OTA-RC and dual-OTA-RC sinusoidal oscillators, there are three other structurally distinct equivalent forms having the same characteristic equation, one of which employs both grounded capacitors (GC. In this study, an earlier nullor-based theory of generating equivalent op-amp oscillator circuits, proposed by the first author, is extended to derive equivalent OTA-RC circuits which discloses the existence of an additional number of equivalent forms for the same given OTA-RC oscillators than those predicted by the quoted earlier works, and thereby considerably enlarging the set of equivalents of a given OTA-RC oscillator. Furthermore, the presented nullor-based theory of generating equivalent OTA-RC oscillators results in three additional interesting outcomes: (i the revelation that corresponding to any given OTA-RC oscillator there are two ‘both-GC’ oscillators (and not merely one, as derived in the quoted earlier works; (ii the availability of explicit current outputs in several of the derived equivalents and (iii the realisability explicit-current-output ‘quadrature oscillators’ in some of the generated equivalent oscillators. The workability of the generated equivalent OTA-RC oscillators has been verified by SPICE simulations, based on CMOS OTAs using 0.18 µm CMOS technology process parameters, and some sample results are given.

  2. The lead equivalence of plate glass for diagnostic x-rays

    International Nuclear Information System (INIS)

    Young, B.F.; Morris, N.D.

    1983-01-01

    The effectiveness of plate glass as a radiation protection barrier was determined. For x ray energies between 80 and 140 kVp, the lead equivalence of plate glass is energy independent, but below 80 kVp there is an apparent dependence. A thickness of plate glass of 25 mm for radiation energies between 80 and 140 kVp is equivalent to lead of .3mm thickness. There could be a limited application for the use of plate glass in viewing panels

  3. The principle of equivalence and the Trojan asteroids

    International Nuclear Information System (INIS)

    Orellana, R.; Vucetich, H.

    1986-05-01

    An analysis of the Trojan asteroids motion has been carried out in order to set limits to possible violations to the principle of equivalence. Preliminary results, in agreement with general relativity, are reported. (author)

  4. Sample size determination for equivalence assessment with multiple endpoints.

    Science.gov (United States)

    Sun, Anna; Dong, Xiaoyu; Tsong, Yi

    2014-01-01

    Equivalence assessment between a reference and test treatment is often conducted by two one-sided tests (TOST). The corresponding power function and sample size determination can be derived from a joint distribution of the sample mean and sample variance. When an equivalence trial is designed with multiple endpoints, it often involves several sets of two one-sided tests. A naive approach for sample size determination in this case would select the largest sample size required for each endpoint. However, such a method ignores the correlation among endpoints. With the objective to reject all endpoints and when the endpoints are uncorrelated, the power function is the production of all power functions for individual endpoints. With correlated endpoints, the sample size and power should be adjusted for such a correlation. In this article, we propose the exact power function for the equivalence test with multiple endpoints adjusted for correlation under both crossover and parallel designs. We further discuss the differences in sample size for the naive method without and with correlation adjusted methods and illustrate with an in vivo bioequivalence crossover study with area under the curve (AUC) and maximum concentration (Cmax) as the two endpoints.

  5. Equivalent Modeling of DFIG-Based Wind Power Plant Considering Crowbar Protection

    Directory of Open Access Journals (Sweden)

    Qianlong Zhu

    2016-01-01

    Full Text Available Crowbar conduction has an impact on the transient characteristics of a doubly fed induction generator (DFIG in the short-circuit fault condition. But crowbar protection is seldom considered in the aggregation method for equivalent modeling of DFIG-based wind power plants (WPPs. In this paper, the relationship between the growth of postfault rotor current and the amplitude of the terminal voltage dip is studied by analyzing the rotor current characteristics of a DFIG during the fault process. Then, a terminal voltage dip criterion which can identify crowbar conduction is proposed. Considering the different grid connection structures for single DFIG and WPP, the criterion is revised and the crowbar conduction is judged depending on the revised criterion. Furthermore, an aggregation model of the WPP is established based on the division principle of crowbar conduction. Finally, the proposed equivalent WPP is simulated on a DIgSILENT PowerFactory platform and the results are compared with those of the traditional equivalent WPPs and the detailed WPP. The simulation results show the effectiveness of the method for equivalent modeling of DFIG-based WPP when crowbar protection is also taken into account.

  6. A design of ambient dose equivalent dosimeter and its dosimetric performance

    International Nuclear Information System (INIS)

    Zhao Shian; Ou Xiangming; Li Kaibao

    1997-01-01

    Objective: To design an ambient dose equivalent dosimeter with digital display for radiation protection, which is based on the definition of the new operational radiation quantity for environmental monitoring-ambient dose equivalent recommended by the International Commission on Radiation Units and Measurements (ICRU) Report 39. Methods: Considering the energy response of the instrument, the inner wall of ionizing chamber is coated with gum graphite added with a bit of metal powder. Results: Using this chamber, measurement of H * (10) for photon radiation with unknown spectrum distribution is possible in the energy range from 47 keV to 230 keV with an uncertainty of better than 5%. The configuration, technology and dosimetric performance of the chamber and automatic functions of the reader are presented. Conclusion: The ambient dose equivalent dosimeter can be used as not only a working reference dosimeter, but also a field dosimeter for radiation protection because the readings are expressed directly in ambient dose equivalent and averaged automatically in the period of measurement. Also, its power is supplied by battery for the portable purpose and the readings are displayed on the screen with light-background for dim field

  7. Assessing Formal Knowledge of Math Equivalence among Algebra and Pre-Algebra Students

    Science.gov (United States)

    Fyfe, Emily R.; Matthews, Percival G.; Amsel, Eric; McEldoon, Katherine L.; McNeil, Nicole M.

    2018-01-01

    A central understanding in mathematics is knowledge of "math equivalence," the relation indicating that 2 quantities are equal and interchangeable. Decades of research have documented elementary-school (ages 7 to 11) children's (mis)understanding of math equivalence, and recent work has developed a construct map and comprehensive…

  8. Application of A150-plastic equivalent gases in microdosimetric measurements

    International Nuclear Information System (INIS)

    DeLuca, P.M. Jr.; Higgins, P.D.; Pearson, D.W.; Schell, M.; Attix, F.H.

    1981-01-01

    Neutron dosimetry measurements with ionization chambers, for the most part, employ tissue equivalent plastic-walled cavities (Shonka A150) filled with either air or a methane-base tissue-like gas. The atomic composition of TE-gas and A150 plastic are not matched and are quite dissimilar from muscle. Awschalom and Attix (1980) have partially resolved the problem by formulating a novel A150-plastic equivalent gas. This establishes a homogeneous wall-gas cavity dosimeter for neutron measurements and confines the necessary corrections to the applications of kerma ratios. In this report, we present measurements of applications of two A150-plastic equivalent gases in a low pressure spherical proportional counter. Gas gains and alpha-particle resolutions were determined. For these A150-mixtures as well as a methane-based TE-gas and an Ar-CO 2 mixture, we report measurements of event size distributions from exposure to a beam of 14.8 MeV neutrons

  9. 75 FR 9894 - Office of Research and Development; Ambient Air Monitoring Reference and Equivalent Methods...

    Science.gov (United States)

    2010-03-04

    ..., Research Triangle Park, North Carolina 27711. Designation of this new equivalent method is intended to... ENVIRONMENTAL PROTECTION AGENCY [FRL-9121-6] Office of Research and Development; Ambient Air Monitoring Reference and Equivalent Methods: Designation of One New Equivalent Method AGENCY: Environmental...

  10. 76 FR 15974 - Office of Research and Development; Ambient Air Monitoring Reference and Equivalent Methods...

    Science.gov (United States)

    2011-03-22

    ..., Research Triangle Park, North Carolina 27711. Designation of these new equivalent methods is intended to... ENVIRONMENTAL PROTECTION AGENCY [FRL-9285-2] Office of Research and Development; Ambient Air Monitoring Reference and Equivalent Methods: Designation of Four New Equivalent Methods AGENCY: Environmental...

  11. 75 FR 51039 - Office of Research and Development; Ambient Air Monitoring Reference and Equivalent Methods...

    Science.gov (United States)

    2010-08-18

    ..., Research Triangle Park, North Carolina 27711. Designation of these new equivalent methods is intended to... ENVIRONMENTAL PROTECTION AGENCY [FRL-9190-5] Office of Research and Development; Ambient Air Monitoring Reference and Equivalent Methods: Designation of Two New Equivalent Methods AGENCY: Environmental...

  12. Characterization of tissue-equivalent materials for use in construction of physical phantoms

    International Nuclear Information System (INIS)

    Souza, Edvan V. de; Oliveira, Alex C.H. de; Vieira, Jose W.; Lima, Fernando R.A.

    2013-01-01

    Phantoms are physical or computational models used to simulate the transport of ionizing radiation, their interactions with human body tissues and evaluate the deposition of energy. Depending on the application, you can build phantoms of various types and features. The physical phantoms are made of materials with behavior similar to human tissues exposed to ionizing radiation, the so-called tissue-equivalent materials. The characterization of various tissue-equivalent materials is important for the choice of materials to be used is appropriate, seeking a better cost-benefit ratio. The main objective of this work is to produce tables containing the main characteristics of tissue-equivalent materials. These tables were produced in Microsoft Office Excel. Among the main features of tissue-equivalent materials that were added to the tables, are density, chemical composition, physical state, chemical stability and solubility. The main importance of this work is to contribute to the construction of high-quality physical phantoms and avoid the waste of materials

  13. Noncommutative Yang-Mills from equivalence of star products

    International Nuclear Information System (INIS)

    Jurco, B.; Schupp, P.

    2000-01-01

    It is shown that the transformation between ordinary and noncommutative Yang-Mills theory as formulated by Seiberg and Witten is due to the equivalence of certain star products on the D-brane world-volume. (orig.)

  14. Noncommutative Yang-Mills from equivalence of star products

    Energy Technology Data Exchange (ETDEWEB)

    Jurco, B. [Max-Planck-Institut fuer Mathematik, Bonn (Germany); Schupp, P. [Sektion Physik, Universitaet Muenchen, Theresienstrasse 37, 80333 Muenchen (Germany)

    2000-05-01

    It is shown that the transformation between ordinary and noncommutative Yang-Mills theory as formulated by Seiberg and Witten is due to the equivalence of certain star products on the D-brane world-volume. (orig.)

  15. Controlling human corneal stromal stem cell contraction to mediate rapid cell and matrix organization of real architecture for 3-dimensional tissue equivalents.

    Science.gov (United States)

    Mukhey, Dev; Phillips, James B; Daniels, Julie T; Kureshi, Alvena K

    2018-02-01

    The architecture of the human corneal stroma consists of a highly organized extracellular matrix (ECM) interspersed with keratocytes. Their progenitor cells; corneal stromal stem cells (CSSC) are located at the periphery, in the limbal stroma. A highly organized corneal ECM is critical for effective transmission of light but this structure may be compromised during injury or disease, resulting in loss of vision. Re-creating normal organization in engineered tissue equivalents for transplantation often involves lengthy culture times that are inappropriate for clinical use or utilisation of synthetic substrates that bring complications such as corneal melting. CSSC have great therapeutic potential owing to their ability to reorganize a disorganized matrix, restoring transparency in scarred corneas. We examined CSSC contractile behavior to assess whether this property could be exploited to rapidly generate cell and ECM organization in Real Architecture For 3D Tissues (RAFT) tissue equivalents (TE) for transplantation. Free-floating collagen gels were characterized to assess contractile behavior of CSSC and establish optimum cell density and culture times. To mediate cell and collagen organization, tethered collagen gels seeded with CSSC were cultured and subsequently stabilized with the RAFT process. We demonstrated rapid creation of biomimetic RAFT TE with tunable structural properties. These displayed three distinct regions of varying degrees of cellular and collagen organization. Interestingly, increased organization coincided with a dramatic loss of PAX6 expression in CSSC, indicating rapid differentiation into keratocytes. The organized RAFT TE system could be a useful bioengineering tool to rapidly create an organized ECM while simultaneously controlling cell phenotype. For the first time, we have demonstrated that human CSSC exhibit the phenomenon of cellular self-alignment in tethered collagen gels. We found this mediated rapid co-alignment of collagen fibrils

  16. Equivalence of two non-commutative geometry approaches

    International Nuclear Information System (INIS)

    Guo Hanying; Wu Ke; Li Jianming.

    1994-10-01

    We show that differential calculus on discrete group Z 2 is equivalent to A. Connes' approach in the case of two discrete points. They are the same theory in terms of different basis and the discrete group Z 2 is the permutation group of two discrete point. (author). 11 refs

  17. Lexicographic Approaches to Sense Disambiguation in Monolingual Dictionaries and Equivalent Differentiation in Bilingual Dictionaries

    Directory of Open Access Journals (Sweden)

    Marjeta Vrbinc

    2011-05-01

    Full Text Available The article discusses methods of sense disambiguation in monolingual dictionaries and equivalent differentiation in bilingual dictionaries. In current dictionaries, sense disambiguation and equivalent differentiation is presented in the form of specifiers or glosses, collocators or indications of context, (domain labels, metalinguistic and encyclopaedic information. Each method is presented and illustrated by actual samples of dictionary articles taken from mono and bilingual dictionaries. The last part of the article is devoted to equivalent differentiation in bilingual decoding dictionaries. In bilingual dictionaries, equivalent differentiation is often needed to describe the lack of agreement between the source language (SL and target language (TL. The article concludes by stating that equivalent differentiation should be written in the native language of the target audience and sense indicators in a monolingual learner’s dictionary should be words that the users are most familiar with.

  18. Conditions for equivalence of statistical ensembles in nuclear multifragmentation

    International Nuclear Information System (INIS)

    Mallik, Swagata; Chaudhuri, Gargi

    2012-01-01

    Statistical models based on canonical and grand canonical ensembles are extensively used to study intermediate energy heavy-ion collisions. The underlying physical assumption behind canonical and grand canonical models is fundamentally different, and in principle agree only in the thermodynamical limit when the number of particles become infinite. Nevertheless, we show that these models are equivalent in the sense that they predict similar results if certain conditions are met even for finite nuclei. In particular, the results converge when nuclear multifragmentation leads to the formation of predominantly nucleons and low mass clusters. The conditions under which the equivalence holds are amenable to present day experiments.

  19. 75 FR 22126 - Office of Research and Development; Ambient Air Monitoring Reference and Equivalent Methods...

    Science.gov (United States)

    2010-04-27

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9142-1] Office of Research and Development; Ambient Air Monitoring Reference and Equivalent Methods: Designation of One New Equivalent Method AGENCY: Environmental Protection Agency. ACTION: Notice of the designation of one new equivalent method for monitoring ambient air...

  20. 76 FR 62402 - Office of Research and Development; Ambient Air Monitoring Reference and Equivalent Methods...

    Science.gov (United States)

    2011-10-07

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9476-7] Office of Research and Development; Ambient Air Monitoring Reference and Equivalent Methods; Designation of One New Equivalent Method AGENCY: Environmental Protection Agency. ACTION: Notice of the designation of one new equivalent method for monitoring ambient air...

  1. 75 FR 30022 - Office of Research and Development; Ambient Air Monitoring Reference and Equivalent Methods...

    Science.gov (United States)

    2010-05-28

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9156-1] Office of Research and Development; Ambient Air Monitoring Reference and Equivalent Methods: Designation of One New Equivalent Method AGENCY: Environmental Protection Agency. ACTION: Notice of the designation of one new equivalent method for monitoring ambient air...

  2. Evaluation of 1cm dose equivalent rate using a NaI(Tl) scintilation spectrometer

    International Nuclear Information System (INIS)

    Matsuda, Hideharu

    1990-01-01

    A method for evaluating 1 cm dose equivalent rates from a pulse height distribution obtained by a 76.2mmφ spherical NaI(Tl) scintillation spectrometer was described. Weak leakage radiation from nuclear facilities were also measured and dose equivalent conversion factor and effective energy of leakage radiation were evaluated from 1 cm dose equivalent rate and exposure rate. (author)

  3. Semantical Characterizations and Complexity of Equivalences in Answer Set Programming

    OpenAIRE

    Eiter, Thomas; Fink, Michael; Woltran, Stefan

    2005-01-01

    In recent research on non-monotonic logic programming, repeatedly strong equivalence of logic programs P and Q has been considered, which holds if the programs P union R and Q union R have the same answer sets for any other program R. This property strengthens equivalence of P and Q with respect to answer sets (which is the particular case for R is the empty set), and has its applications in program optimization, verification, and modular logic programming. In this paper, we consider more lib...

  4. An equivalent condition for stability properties of Lotka-Volterra systems

    International Nuclear Information System (INIS)

    Chu Tianguang

    2007-01-01

    We give a solvable Lie algebraic condition for the equivalence of four typical stability notions (asymptotic stability, D-stability, total stability, and Volterra-Lyapunov stability) concerning Lotka-Volterra systems. Our approach makes use of the decomposition of the interaction matrix into symmetric and skew-symmetric parts, which may be related to the cooperative and competitive interaction pattern of a Lotka-Volterra system. The present result covers a known condition and can yield a larger set of interaction matrices for equivalence of the stability properties

  5. Fatigue Equivalent Stress State Approach Validation in Non-conservative Criteria: a Comparative Study

    Directory of Open Access Journals (Sweden)

    Kévin Martial Tsapi Tchoupou

    Full Text Available Abstract This paper is concerned with the fatigue prediction models for estimating the multiaxial fatigue limit. An equivalent loading approach with zero out-of-phase angles intended for fatigue limit evaluation under multiaxial loading is used. Based on experimental data found in literatures, the equivalent stress is validated in Crossland and Sines criteria and predictions compared to the predictions of existing multiaxial fatigue; results over 87 experimental items show that the equivalent stress approach is very efficient.

  6. Benefits of the effective dose equivalent concept at a medical center

    International Nuclear Information System (INIS)

    Vetter, R.J.; Classic, K.L.

    1991-01-01

    A primary objective of the recommendations of the International Committee on Radiological Protection Publication 26 is to insure that no source of radiation exposure is unjustified in relation to its benefits. This objective is consistent with goals of the Radiation Safety Committee and Institutional Review Board at medical centers where research may involve radiation exposure of human subjects. The effective dose equivalent concept facilitates evaluation of risk by those who have little or no knowledge of quantities or biological effects of radiation. This paper presents effective dose equivalent data used by radiation workers and those who evaluate human research protocols as these data relate to personal dosimeter reading, entrance skin exposure, and target organ dose. The benefits of using effective dose equivalent to evaluate risk of medical radiation environments and research protocols are also described

  7. Free Fall and the Equivalence Principle Revisited

    Science.gov (United States)

    Pendrill, Ann-Marie

    2017-01-01

    Free fall is commonly discussed as an example of the equivalence principle, in the context of a homogeneous gravitational field, which is a reasonable approximation for small test masses falling moderate distances. Newton's law of gravity provides a generalisation to larger distances, and also brings in an inhomogeneity in the gravitational field.…

  8. Examination of the equivalence of self-report survey-based paper-and-pencil and internet data collection methods.

    Science.gov (United States)

    Weigold, Arne; Weigold, Ingrid K; Russell, Elizabeth J

    2013-03-01

    Self-report survey-based data collection is increasingly carried out using the Internet, as opposed to the traditional paper-and-pencil method. However, previous research on the equivalence of these methods has yielded inconsistent findings. This may be due to methodological and statistical issues present in much of the literature, such as nonequivalent samples in different conditions due to recruitment, participant self-selection to conditions, and data collection procedures, as well as incomplete or inappropriate statistical procedures for examining equivalence. We conducted 2 studies examining the equivalence of paper-and-pencil and Internet data collection that accounted for these issues. In both studies, we used measures of personality, social desirability, and computer self-efficacy, and, in Study 2, we used personal growth initiative to assess quantitative equivalence (i.e., mean equivalence), qualitative equivalence (i.e., internal consistency and intercorrelations), and auxiliary equivalence (i.e., response rates, missing data, completion time, and comfort completing questionnaires using paper-and-pencil and the Internet). Study 1 investigated the effects of completing surveys via paper-and-pencil or the Internet in both traditional (i.e., lab) and natural (i.e., take-home) settings. Results indicated equivalence across conditions, except for auxiliary equivalence aspects of missing data and completion time. Study 2 examined mailed paper-and-pencil and Internet surveys without contact between experimenter and participants. Results indicated equivalence between conditions, except for auxiliary equivalence aspects of response rate for providing an address and completion time. Overall, the findings show that paper-and-pencil and Internet data collection methods are generally equivalent, particularly for quantitative and qualitative equivalence, with nonequivalence only for some aspects of auxiliary equivalence. PsycINFO Database Record (c) 2013 APA, all

  9. Establishing Substantial Equivalence: Proteomics

    Science.gov (United States)

    Lovegrove, Alison; Salt, Louise; Shewry, Peter R.

    Wheat is a major crop in world agriculture and is consumed after processing into a range of food products. It is therefore of great importance to determine the consequences (intended and unintended) of transgenesis in wheat and whether genetically modified lines are substantially equivalent to those produced by conventional plant breeding. Proteomic analysis is one of several approaches which can be used to address these questions. Two-dimensional PAGE (2D PAGE) remains the most widely available method for proteomic analysis, but is notoriously difficult to reproduce between laboratories. We therefore describe methods which have been developed as standard operating procedures in our laboratory to ensure the reproducibility of proteomic analyses of wheat using 2D PAGE analysis of grain proteins.

  10. [Predictors of the therapeutic discharge in patients with dual pathology admitted to a therapeutic community with a psychiatric unit].

    Science.gov (United States)

    Madoz-Gúrpide, Agustín; García Vicent, Vicente; Luque Fuentes, Encarnación; Ochoa Mangado, Enriqueta

    2013-01-01

    This study aims to analyze the variables on which depends therapeutic discharge, in patients with a severe dual diagnosis admitted to a professional therapeutic community where their pathology is treated. 325 patients admitted between June 2000 and June 2009 to the therapeutic community. This is a retrospective, cross-sectional study with no control group, based on the detailed analysis of the information collected in a model of semi-structured clinical interview designed in the therapeutic community. The 29.5% of the individuals included in the sample were therapeutically discharged. Of all the variables introduced in this analysis the most significant ones were gender, age at the beginning of treatment, education level, opiate dependence, polidrug abuse, and the presence of psychotic disorders and borderline personality disorder. In our study, gender determines the type of discharge, being therapeutic discharge more frequent among women. A higher educational also increases a better prognosis with a higher rate of therapeutic discharge among individuals with higher education level. A later age at the beginning of the treatment reduces the likelihood of therapeutic discharge. Likewise, polidrug abuse, diagnosis of psychotic disorders and borderline personality disorder are associated to a lower rate of therapeutic discharge. Recognizing these characteristics will allow the early identification of those patients more at risk of dropping treatment hastily, while trying to prevent it by increasing the therapeutic intensity.

  11. Lidar cross-sections of soot fractal aggregates: Assessment of equivalent-sphere models

    Science.gov (United States)

    Ceolato, Romain; Gaudfrin, Florian; Pujol, Olivier; Riviere, Nicolas; Berg, Matthew J.; Sorensen, Christopher M.

    2018-06-01

    This work assesses the ability of equivalent-sphere models to reproduce the optical properties of soot aggregates relevant for lidar remote sensing, i.e. the backscattering and extinction cross sections. Lidar cross-sections are computed with a spectral discrete dipole approximation model over the visible-to-infrared (400-5000 nm) spectrum and compared with equivalent-sphere approximations. It is shown that the equivalent-sphere approximation, applied to fractal aggregates, has a limited ability to calculate such cross-sections well. The approximation should thus be used with caution for the computation of broadband lidar cross-sections, especially backscattering, at small and intermediate wavelengths (e.g. UV to visible).

  12. Energy response of detectors to alpha/beta particles and compatibility of the equivalent factors

    International Nuclear Information System (INIS)

    Lin Bingxing; Li Guangxian; Lin Lixiong

    2011-01-01

    By measuring detect efficiency and equivalent factors of alpha/beta radiation with different energies on three types of detectors, this paper compares compatibility of their equivalent factors and discusses applicability of detectors to measuring total alpha/beta radiation. The result shows the relationship between efficiency of alpha/beta radiation and their energies on 3 types of detectors, such as scintillation and proportional and semiconductor counters, are overall identical. Alpha count efficiency display exponential relation with alpha-particle energy. While beta count efficiency display logarithm relation with beta-particle energy, but the curves appears deflection at low energy. Comparison test of energy response also shows that alpha and beta equivalent factors of scintillation and proportional counters have a good compatibility, and alpha equivalent factors of the semiconductor counters are in good agreement with those of the above two types of counters, but beta equivalent factors have obvious difference, or equivalent factors of low energy beta-particle are lower than those of other detectors. So, the semiconductor counter can not be used for measuring total radioactivity or for the measurements for the purpose of food safety. (authors)

  13. Universal Survival Curve and Single Fraction Equivalent Dose: Useful Tools in Understanding Potency of Ablative Radiotherapy

    International Nuclear Information System (INIS)

    Park, Clint; Papiez, Lech; Zhang Shichuan; Story, Michael; Timmerman, Robert D.

    2008-01-01

    Purpose: Overprediction of the potency and toxicity of high-dose ablative radiotherapy such as stereotactic body radiotherapy (SBRT) by the linear quadratic (LQ) model led to many clinicians' hesitating to adopt this efficacious and well-tolerated therapeutic option. The aim of this study was to offer an alternative method of analyzing the effect of SBRT by constructing a universal survival curve (USC) that provides superior approximation of the experimentally measured survival curves in the ablative, high-dose range without losing the strengths of the LQ model around the shoulder. Methods and Materials: The USC was constructed by hybridizing two classic radiobiologic models: the LQ model and the multitarget model. We have assumed that the LQ model gives a good description for conventionally fractionated radiotherapy (CFRT) for the dose to the shoulder. For ablative doses beyond the shoulder, the survival curve is better described as a straight line as predicted by the multitarget model. The USC smoothly interpolates from a parabola predicted by the LQ model to the terminal asymptote of the multitarget model in the high-dose region. From the USC, we derived two equivalence functions, the biologically effective dose and the single fraction equivalent dose for both CFRT and SBRT. Results: The validity of the USC was tested by using previously published parameters of the LQ and multitarget models for non-small-cell lung cancer cell lines. A comparison of the goodness-of-fit of the LQ and USC models was made to a high-dose survival curve of the H460 non-small-cell lung cancer cell line. Conclusion: The USC can be used to compare the dose fractionation schemes of both CFRT and SBRT. The USC provides an empirically and a clinically well-justified rationale for SBRT while preserving the strengths of the LQ model for CFRT

  14. Constraints on equivalent elastic source models from near-source data

    International Nuclear Information System (INIS)

    Stump, B.

    1993-01-01

    A phenomenological based seismic source model is important in quantifying the important physical processes that affect the observed seismic radiation in the linear-elastic regime. Representations such as these were used to assess yield effects on seismic waves under a Threshold Test Ban Treaty and to help transport seismic coupling experience at one test site to another. These same characterizations in a non-proliferation environment find applications in understanding the generation of the different types of body and surface waves from nuclear explosions, single chemical explosions, arrays of chemical explosions used in mining, rock bursts and earthquakes. Seismologists typically begin with an equivalent elastic representation of the source which when convolved with the propagation path effects produces a seismogram. The Representation Theorem replaces the true source with an equivalent set of body forces, boundary conditions or initial conditions. An extension of this representation shows the equivalence of the body forces, boundary conditions and initial conditions and replaces the source with a set of force moments, the first degree moment tensor for a point source representation. The difficulty with this formulation, which can completely describe the observed waveforms when the propagation path effects are known, is in the physical interpretation of the actual physical processes acting in the source volume. Observational data from within the source region, where processes are often nonlinear, linked to numerical models of the important physical processes in this region are critical to a unique physical understanding of the equivalent elastic source function

  15. Therapeutic applications of radiopharmaceuticals

    International Nuclear Information System (INIS)

    Baker, W.J.; Datz, F.L.; Beightol, R.W.

    1987-01-01

    Whether a radiopharmaceutical has diagnostic or therapeutic application depends on both the isotope and pharmaceutical used. For diagnostic applications, the isotope should undergo only γ-decay, since usually only γ-radiation is detected by nuclear medicine cameras. The half-life should be just long enough to allow the procedure to be performed. In contrast, the isotope needed for therapeutic purposes should have particulate radiation, such as a β-particle (electron), since these are locally absorbed an increase the local radiation dose. γ-Radiation, which penetrates the tissues, produces less radiation dose than do Β-particles. Several references dealing with radioactive decay, particulate interactions, and diagnostic and therapeutic applications of radiopharmaceuticals are available. Radiopharmaceuticals can legally be used only by physicians who are qualified by specific training in the safe handling of radionuclides. The experience and training of these physicians must be approved by the Nuclear Regulatory Commission or Agreement State Agency authorized to license the use of radiopharmaceuticals. A list of all byproduct material and procedures is available in the Code of Federal Regulations. Of the many radiopharmaceuticals available for diagnostic and therapeutic use, only those commonly used are discussed in this chapter

  16. A Logical Characterisation of Static Equivalence

    DEFF Research Database (Denmark)

    Hüttel, Hans; Pedersen, Michael D.

    2007-01-01

    -order logic for frames with quantification over environment knowledge which, under certain general conditions, characterizes static equivalence and is amenable to construction of characteristic formulae. The logic can be used to reason about environment knowledge and can be adapted to a particular application...... by defining a suitable signature and associated equational theory. The logic can furthermore be extended with modalities to yield a modal logic for e.g. the Applied Pi calculus....

  17. Global transport calculations with an equivalent barotropic system

    Science.gov (United States)

    Salby, Murry L.; O'Sullivan, Donal; Garcia, Rolando R.; Tribbia, Joseph

    1990-01-01

    Transport properties of the two-dimensional equations governing equivalent barotropic motion are investigated on the sphere. This system has ingredients such as forcing, equivalent depth, and thermal dissipation explicitly represented, and takes into account compression effects associated with vertical motion along isentropic surfaces. Horizontal transport properties of this system are investigated under adiabatic and diabatic conditions for different forms of dissipation, and over a range of resolutions. It is shown that forcing represetative of time-mean and amplified conditions at 10 mb leads to the behavior typical of observations at this level. The displacement of the polar night vortex and its distortion into a comma shape are evident, as is irreversible mixing under sufficiently strong forcing amplitude. It is shown that thermal dissipation influences the behavior significantly by inhibiting the amplification of unstable eddies and thereby the horizontal stirring of air.

  18. Equivalence of two models in single-phase multicomponent flow simulations

    KAUST Repository

    Wu, Yuanqing

    2016-02-28

    In this work, two models to simulate the single-phase multicomponent flow in reservoirs are introduced: single-phase multicomponent flow model and two-phase compositional flow model. Because the single-phase multicomponent flow is a special case of the two-phase compositional flow, the two-phase compositional flow model can also simulate the case. We compare and analyze the two models when simulating the single-phase multicomponent flow, and then demonstrate the equivalence of the two models mathematically. An experiment is also carried out to verify the equivalence of the two models.

  19. Equivalence of two models in single-phase multicomponent flow simulations

    KAUST Repository

    Wu, Yuanqing; Sun, Shuyu

    2016-01-01

    In this work, two models to simulate the single-phase multicomponent flow in reservoirs are introduced: single-phase multicomponent flow model and two-phase compositional flow model. Because the single-phase multicomponent flow is a special case of the two-phase compositional flow, the two-phase compositional flow model can also simulate the case. We compare and analyze the two models when simulating the single-phase multicomponent flow, and then demonstrate the equivalence of the two models mathematically. An experiment is also carried out to verify the equivalence of the two models.

  20. Possibility and necessity measures and integral equivalence

    Czech Academy of Sciences Publication Activity Database

    Chen, T.; Mesiar, Radko; Li, J.; Stupňanová, A.

    2017-01-01

    Roč. 86, č. 1 (2017), s. 62-72 ISSN 0888-613X Institutional support: RVO:67985556 Keywords : Integral equivalence * Necessity measure * Possibility measure * Survival function * Universal integral Subject RIV: BA - General Mathematics OBOR OECD: Statistics and probability Impact factor: 2.845, year: 2016 http://library.utia.cas.cz/separaty/2017/E/mesiar-0477092.pdf

  1. Therapeutic hypothermia for acute stroke

    DEFF Research Database (Denmark)

    Olsen, Tom Skyhøj; Weber, Uno Jakob; Kammersgaard, Lars Peter

    2003-01-01

    Experimental evidence and clinical experience show that hypothermia protects the brain from damage during ischaemia. There is a growing hope that the prevention of fever in stroke will improve outcome and that hypothermia may be a therapeutic option for the treatment of stroke. Body temperature...... obvious therapeutic potential, hypothermia as a form of neuroprotection for stroke has been investigated in only a few very small studies. Therapeutic hypothermia is feasible in acute stroke but owing to serious side-effects--such as hypotension, cardiac arrhythmia, and pneumonia--it is still thought...

  2. Infrared equivalence of strongly and weakly coupled gauge theories

    International Nuclear Information System (INIS)

    Olesen, P.

    1975-10-01

    Using the decoupling theorem of Apelquist and Carazzone, it is shown that in terms of Feynman diagrams the pure Yang-Mills theory is equivalent in the infrared limit to a theory (zero-mass renormalized), where the vector mesons are coupled fo fermions, and where the fermions do not decouple. By taking enough fermions it is then shown that even though the pure Yang-Mills theory is characterized by the lack of applicability of perturbation theory, nevertheless the effective coupling in the equivalent fermion description is very weak. The effective mass in the zero-mass renormalization blows up. In the fermion description, diagrams involving only vector mesons are suppressed relative to diagrams containing at least one fermion loop. (Auth.)

  3. A first vascularized skin equivalent as an alternative to animal experimentation.

    Science.gov (United States)

    Groeber, Florian; Engelhardt, Lisa; Lange, Julia; Kurdyn, Szymon; Schmid, Freia F; Rücker, Christoph; Mielke, Stephan; Walles, Heike; Hansmann, Jan

    2016-01-01

    Tissue-engineered skin equivalents mimic key aspects of the human skin, and can thus be employed as wound coverage for large skin defects or as in vitro test systems as an alternative to animal models. However, current skin equivalents lack a functional vasculature limiting clinical and research applications. This study demonstrates the generation of a vascularized skin equivalent with a perfused vascular network by combining a biological vascularized scaffold (BioVaSc) based on a decellularized segment of a porcine jejunum and a tailored bioreactor system. Briefly, the BioVaSc was seeded with human fibroblasts, keratinocytes, and human microvascular endothelial cells. After 14 days at the air-liquid interface, hematoxylin & eosin and immunohistological staining revealed a specific histological architecture representative of the human dermis and epidermis including a papillary-like architecture at the dermal-epidermal-junction. The formation of the skin barrier was measured non-destructively using impedance spectroscopy. Additionally, endothelial cells lined the walls of the formed vessels that could be perfused with a physiological volume flow. Due to the presence of a complex in-vivo-like vasculature, the here shown skin equivalent has the potential for skin grafting and represents a sophisticated in vitro model for dermatological research.

  4. Dependence on age at intake of committed dose equivalents from radionuclides

    International Nuclear Information System (INIS)

    Adams, N.

    1981-01-01

    The dependence of committed dose equivalents on age at intake is needed to assess the significance of exposures of young persons among the general public resulting from inhaled or ingested radionuclides. The committed dose equivalents, evaluated using ICRP principles, depend on the body dimensions of the young person at the time of intake of a radionuclide and on subsequent body growth. Representation of growth by a series of exponential segments facilitates the derivation of general expressions for the age dependence of committed dose equivalents if metabolic models do not change with age. The additional assumption that intakes of radionuclides in air or food are proportional to a person's energy expenditure (implying age-independent dietary composition) enables the demonstration that the age of the most highly exposed 'critical groups' of the general public from these radionuclides is either about 1 year or 17 years. With the above assumptions the exposure of the critical group is less than three times the exposure of adult members of the general public. Approximate values of committed dose equivalents which avoid both underestimation and excessive overestimation are shown to be obtainable by simplified procedures. Modified procedures are suggested for use if metabolic models change with age. (author)

  5. Study of a silicon telescope for solid state microdosimetry: Preliminary measurements at the therapeutic proton beam line of CATANA

    International Nuclear Information System (INIS)

    Agosteo, S.; Cirrone, G.A.P.; Colautti, P.; Cuttone, G.; D'Angelo, G.; Fazzi, A.; Introini, M.V.; Moro, D.; Pola, A.; Varoli, V.

    2010-01-01

    A monolithic silicon device consisting of a matrix of micrometric cylindrical diodes (about 2 μm in thickness and 9 μm in diameter) coupled to a residual energy measurement stage E (about 500 μm in thickness) was proposed and studied for assessing the quality of a therapeutic proton beam. The device was placed at different depths inside a polymethyl-methacrylate phantom and irradiated with a modulated 62 MeV proton beam at the Centro di AdroTerapia e Applicazioni Nucleari Avanzate (CATANA) of the Laboratori Nazionali del Sud (LNS, Catania, Italy) of the Istituto Nazionale di Fisica Nucleare (INFN). At each phantom depth, the energy imparted in the two detector stages was measured event-by-event in coincidence mode. The distributions of the energy imparted to the cylindrical diodes were corrected for tissue-equivalence by applying an optimized procedure. In order to perform a comparison with literature data measured with a cylindrical TEPC, the distributions derived with the silicon detector were corrected for shape-equivalence. The agreement with the microdosimetric spectra measured with the TEPC was satisfactory above the detection limit imposed by the electronic noise of the silicon-based system.

  6. Study of a silicon telescope for solid state microdosimetry: Preliminary measurements at the therapeutic proton beam line of CATANA

    Energy Technology Data Exchange (ETDEWEB)

    Agosteo, S. [Politecnico di Milano, Dipartimento di Energia, Sezione di Ingegneria Nucleare, via Ponzio 34/3, 20133 Milano (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Milano, via Celoria 16, 20133 Milano (Italy); Cirrone, G.A.P. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Sud, via S. Sofia 44, 95123 Catania (Italy); Colautti, P. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Legnaro, viale dell' Universita 2, 35020 Legnaro (Italy); Cuttone, G. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Sud, via S. Sofia 44, 95123 Catania (Italy); D' Angelo, G.; Fazzi, A.; Introini, M.V. [Politecnico di Milano, Dipartimento di Energia, Sezione di Ingegneria Nucleare, via Ponzio 34/3, 20133 Milano (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Milano, via Celoria 16, 20133 Milano (Italy); Moro, D. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Legnaro, viale dell' Universita 2, 35020 Legnaro (Italy); Pola, A., E-mail: andrea.pola@polimi.i [Politecnico di Milano, Dipartimento di Energia, Sezione di Ingegneria Nucleare, via Ponzio 34/3, 20133 Milano (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Milano, via Celoria 16, 20133 Milano (Italy); Varoli, V. [Politecnico di Milano, Dipartimento di Energia, Sezione di Ingegneria Nucleare, via Ponzio 34/3, 20133 Milano (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Milano, via Celoria 16, 20133 Milano (Italy)

    2010-12-15

    A monolithic silicon device consisting of a matrix of micrometric cylindrical diodes (about 2 {mu}m in thickness and 9 {mu}m in diameter) coupled to a residual energy measurement stage E (about 500 {mu}m in thickness) was proposed and studied for assessing the quality of a therapeutic proton beam. The device was placed at different depths inside a polymethyl-methacrylate phantom and irradiated with a modulated 62 MeV proton beam at the Centro di AdroTerapia e Applicazioni Nucleari Avanzate (CATANA) of the Laboratori Nazionali del Sud (LNS, Catania, Italy) of the Istituto Nazionale di Fisica Nucleare (INFN). At each phantom depth, the energy imparted in the two detector stages was measured event-by-event in coincidence mode. The distributions of the energy imparted to the cylindrical diodes were corrected for tissue-equivalence by applying an optimized procedure. In order to perform a comparison with literature data measured with a cylindrical TEPC, the distributions derived with the silicon detector were corrected for shape-equivalence. The agreement with the microdosimetric spectra measured with the TEPC was satisfactory above the detection limit imposed by the electronic noise of the silicon-based system.

  7. Equivalent viscous damping procedure for multi-material systems

    International Nuclear Information System (INIS)

    Ahmed, H.; Ma, D.

    1979-01-01

    The inclusion of accurate viscous damping effects in the seismic analysis of nuclear power plants is discussed. A procedure to evaluate and use equivalent viscous damping coefficients in conjunction with the substructure method of finite element analysis is outlined in detail

  8. Guideline values for skin decontamination measures based on nuclidspecific dose equivalent rate factors

    International Nuclear Information System (INIS)

    Pfob, H.; Heinemann, G.

    1992-01-01

    Corresponding dose equivalent rate factors for various radionuclides are now available for determining the skin dose caused by skin contamination. These dose equivalent rate factors take into account all contributions from the types of radiation emitted. Any limits for skin decontamination measures are nowhere contained or determined yet. However, radiological protection does in practice require at least guideline values in order to prevent unsuitable or detrimental measures that can be noticed quite often. New calculations of dose equivalent rate factors for the skin now make the recommendation of guideline values possible. (author)

  9. A reformulation of the transport-transport SPH equivalence technique

    International Nuclear Information System (INIS)

    Hebert, A.

    2015-01-01

    The superhomogeneisation (SPH) equivalence technique is a correction procedure based on equivalence factors. These equivalence factors are computed in such a way that a macro calculation made over a macro region and a coarse energy group with a simplified transport operator leads to the same leakage and reaction rates as a reference calculation performed without homogenization and with a fine group discretization. The situation where the macro calculation is performed with diffusion theory is a well understood and a common application of the technique. However, the case where the macro calculation is performed in transport theory is more complex and the SPH technique was reformulated in order to take into account the angular parity of the flux moments and cross sections. We found that the general rule to multiply all cross sections by a SPH factor and to divide all flux moment by the same factor is not valid. A new correction strategy is proposed to deal with transport-theory macro calculations. The strategy is slightly different whether or not the macro calculation is performed with a spherical harmonics (PN or SPN) discretization. The new approach was implemented in the DRAGON lattice code. Numerical results are comparing the classical and reformulated techniques. (author)

  10. A reformulation of the transport-transport SPH equivalence technique

    Energy Technology Data Exchange (ETDEWEB)

    Hebert, A., E-mail: alain.hebert@polymtl.ca [Ecole Polytechnique de Montreal, Montreal, QC (Canada)

    2015-07-01

    The superhomogeneisation (SPH) equivalence technique is a correction procedure based on equivalence factors. These equivalence factors are computed in such a way that a macro calculation made over a macro region and a coarse energy group with a simplified transport operator leads to the same leakage and reaction rates as a reference calculation performed without homogenization and with a fine group discretization. The situation where the macro calculation is performed with diffusion theory is a well understood and a common application of the technique. However, the case where the macro calculation is performed in transport theory is more complex and the SPH technique was reformulated in order to take into account the angular parity of the flux moments and cross sections. We found that the general rule to multiply all cross sections by a SPH factor and to divide all flux moment by the same factor is not valid. A new correction strategy is proposed to deal with transport-theory macro calculations. The strategy is slightly different whether or not the macro calculation is performed with a spherical harmonics (PN or SPN) discretization. The new approach was implemented in the DRAGON lattice code. Numerical results are comparing the classical and reformulated techniques. (author)

  11. Equivalence Checking between Pre-synthesis and Post-synthesis Programs by Using VIS

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jonghoon; Yoo, Junbeom [Konkuk Univ., Seoul (Korea, Republic of); Choi, Jonggyun; Lee, Jangsoo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-05-15

    PLC (Programmable Logic Controller)-based Software development, the design programs are translated into implementation programs, and behavioral equivalence between the design and implementation is demonstrated by formal method based technique. In FPGA-based software development, the design programs are also synthesized into implementation programs. However, in this process, testing and simulation based comparison techniques are mainly used. This paper proposes a formal method based technique to demonstrate behavioral equivalence between pre-synthesis and post-synthesis programs with VIS (Verification Interacting with Synthesis) verification system. We translated into BLIF-MV which is front-end of VIS, from Verlag and EDIF net list which synthesized from the same Verlag by an automatic synthesis tool. This paper proposes a formal method based technique to confirm correctness of synthesis by using equivalence checking of VIS verification system. In order to confirm the effectiveness of the proposed technique, we performed a case study with a part of prototype version of the RPS BP, and demonstrated a behavioral equivalence between Verlag HDL and EDIF post-synthesis net list.

  12. Equivalence Checking between Pre-synthesis and Post-synthesis Programs by Using VIS

    International Nuclear Information System (INIS)

    Lee, Jonghoon; Yoo, Junbeom; Choi, Jonggyun; Lee, Jangsoo

    2013-01-01

    PLC (Programmable Logic Controller)-based Software development, the design programs are translated into implementation programs, and behavioral equivalence between the design and implementation is demonstrated by formal method based technique. In FPGA-based software development, the design programs are also synthesized into implementation programs. However, in this process, testing and simulation based comparison techniques are mainly used. This paper proposes a formal method based technique to demonstrate behavioral equivalence between pre-synthesis and post-synthesis programs with VIS (Verification Interacting with Synthesis) verification system. We translated into BLIF-MV which is front-end of VIS, from Verlag and EDIF net list which synthesized from the same Verlag by an automatic synthesis tool. This paper proposes a formal method based technique to confirm correctness of synthesis by using equivalence checking of VIS verification system. In order to confirm the effectiveness of the proposed technique, we performed a case study with a part of prototype version of the RPS BP, and demonstrated a behavioral equivalence between Verlag HDL and EDIF post-synthesis net list

  13. An equivalent fluid/equivalent medium approach for the numerical simulation of coastal landslides propagation: theory and case studies

    Directory of Open Access Journals (Sweden)

    P. Mazzanti

    2009-11-01

    Full Text Available Coastal and subaqueous landslides can be very dangerous phenomena since they are characterised by the additional risk of induced tsunamis, unlike their completely-subaerial counterparts. Numerical modelling of landslides propagation is a key step in forecasting the consequences of landslides. In this paper, a novel approach named Equivalent Fluid/Equivalent Medium (EFEM has been developed. It adapts common numerical models and software that were originally designed for subaerial landslides in order to simulate the propagation of combined subaerial-subaqueous and completely-subaqueous landslides. Drag and buoyancy forces, the loss of energy at the landslide-water impact and peculiar mechanisms like hydroplaning can be suitably simulated by this approach; furthermore, the change in properties of the landslide's mass, which is encountered at the transition from the subaerial to the submerged environment, can be taken into account. The approach has been tested by modelling two documented coastal landslides (a debris flow and a rock slide at Lake Albano using the DAN-W code. The results, which were achieved from the back-analyses, demonstrate the efficacy of the approach to simulate the propagation of different types of coastal landslides.

  14. Equivalent Air Spring Suspension Model for Quarter-Passive Model of Passenger Vehicles.

    Science.gov (United States)

    Abid, Haider J; Chen, Jie; Nassar, Ameen A

    2015-01-01

    This paper investigates the GENSIS air spring suspension system equivalence to a passive suspension system. The SIMULINK simulation together with the OptiY optimization is used to obtain the air spring suspension model equivalent to passive suspension system, where the car body response difference from both systems with the same road profile inputs is used as the objective function for optimization (OptiY program). The parameters of air spring system such as initial pressure, volume of bag, length of surge pipe, diameter of surge pipe, and volume of reservoir are obtained from optimization. The simulation results show that the air spring suspension equivalent system can produce responses very close to the passive suspension system.

  15. The Use Of Optical Properties Of Cr-39 In Alpha Particle Equivalent Dose Measurements

    International Nuclear Information System (INIS)

    Shnishin, K.A.

    2007-01-01

    In this work, optical properties of alpha irradiated Cr-39 were measured as a function of optical photon wavelength from 200-1100 nm. Optical energy gap and optical absorption at finite wavelength was also calculated and correlated to alpha fluence and dose equivalent. Alpha doses were calculated from the corresponding irradiation fluence and specific energy loss using TRIM computer program. It was found that, the optical absorption of unattached Cr-39 was varied with alpha fluence and corresponding equivalent doses. Also the optical energy gab was varied with fluence and dose equivalent of alpha particles. This work introduces a reasonably simple method for the Rn dose equivalent calculation by Cr-39 track

  16. In Quest of Sufficient Equivalence. Polish and English Insolvency Terminology in Translation. a Comparative Study

    Directory of Open Access Journals (Sweden)

    Matulewska Aleksandra

    2014-09-01

    Full Text Available The paper deals with the problem of translating selected insolvency terminology from Polish into English and from English into Polish. The re- search corpora encompassed the Insolvency Act 1986 (England and Wales as amended and Ustawa z dnia 28 lutego 2003. Prawo upadłościowe i naprawcze [the Act on Polish Insolvency and Rehabilitation Law of 28th February 2003 as amended]. The research methods included: (i the comparison of parallel texts, (ii the method of axiomatisation of the legal linguistic reality, (iii the termino- logical analysis of the corpus material, (iv the concept of adjusting the target text to the communicative needs and requirements of the community of recipients and (v the techniques of providing equivalents for non-equivalent terminology. The research hypothesis has been so formulated that the parametrisation of legal reality may assist in finding more adequate equivalents and determine differences in meaning of compared source and target language terms, which in turn facilitates the choice of a more adequate technique of providing equivalents for non-equivalent or partially equivalent legal terminology meeting the com- municative needs of translation recipients. The research results revealed that insolvency terminology is highly system-bound and available equivalents may often be misleading for the community of target text recipients

  17. Quantum mechanics from an equivalence principle

    International Nuclear Information System (INIS)

    Faraggi, A.E.

    1997-01-01

    The authors show that requiring diffeomorphic equivalence for one-dimensional stationary states implies that the reduced action S 0 satisfies the quantum Hamilton-Jacobi equation with the Planck constant playing the role of a covariantizing parameter. The construction shows the existence of a fundamental initial condition which is strictly related to the Moebius symmetry of the Legendre transform and to its involutive character. The universal nature of the initial condition implies the Schroedinger equation in any dimension

  18. Equivalent thermal conductivity of the storage basket with spent nuclear fuel of VVER-1000 reactors

    International Nuclear Information System (INIS)

    Alyokhina, Svitlana; Kostikov, Andriy

    2014-01-01

    Due to limitation of computation resources and/or computation time many thermal problems require to use simplified geometrical models with equivalent thermal properties. A new method for definition of equivalent thermal conductivity of spent nuclear fuel storage casks is proposed. It is based on solving the inverse heat conduction problem. For the proposed method two approaches for equivalent thermal conductivity definition were considered. In the first approach a simplified model in conjugate formulation is used, in the second approach a simplified model of solid body which allows an analytical solution is used. For safety ensuring during all time of spent nuclear fuel storage the equivalent thermal conductivity was calculated for different storage years. The calculated equivalent thermal conductivities can be used in thermal researches for dry spent nuclear fuel storage safety.

  19. School Principals' Leadership Skills: Measurement Equivalence across Cultures

    Science.gov (United States)

    Da'as, Rima'a

    2017-01-01

    Despite substantial interest and research in measuring leader's skills, little is known about the measurement equivalence and mean differences in the scores measuring principals' skills (cognitive, interpersonal, strategic) across cultures (collectivism versus individualism). The aim of the present study was to assess measurement…

  20. [End therapeutic nihilism towards COPD].

    Science.gov (United States)

    Juergens, Uwe R

    2007-03-15

    Prevention of COPD requires appropriate patient education, especially of adolescents, as well as the establishment of an effective national health policy. The new GOLD guidelines represent the current standard of knowledge on the management of chronic, progressive, obstructive pulmonary diseases. It points out that COPD is avoidable and treatable,and hence, there is no reason for therapeutic nihilism. Chronic bronchitis preceding a progressive respiratory obstruction cannot be improved with the presently available respiratory therapeutics. For this reason, therapeutic measures concentrate on the avoidance of exacerbations, which are primarily responsible for the severity of the course of COPD.

  1. A Brief Review of Therapeutic and Diagnostic Applications of Enema in Iranian Traditional Medicine and Other Complementary Medicines

    Directory of Open Access Journals (Sweden)

    Hamideh khorrampazouh

    2018-02-01

    Full Text Available Introduction: Enema or ‘hoqne’ is a therapeutic approach used for a wide range of diseases in the Iranian traditional medicine. The use of this method dates back to thousands of years to Hippocrates and Galen. The aim of this study was to review the history of enema and its methods and indices in the Iranian medicine and other complementary medicine.Methods: This review study was conducted on the Iranian medicine textbooks and articles published in the international databases, including Google Scholar, PubMed, Embase, and Scopus, as well as the Iranian databases, such as SID and Magiran. The searching process was performed using the following keywords: ‘Hoqne’, ‘Enema’, ‘Vasta’, ‘Basta’, and ‘Complementary and Alternative Medicine (CAM’. There was no limitation regarding the publication data of the included studies.Result: In the Iranian medicine, the term “hoqne” is equivalent to enema. Enema is used in various diseases of the brain, respiratory system, digestive system, urogenital system, and musculoskeletal system, as well as systemic diseases. Enema is one of the five main therapies in the Indian medicine or Ayurveda. In other types of complementary medicine, including Chinese medicine, this procedure has therapeutic applications. Although enema has been recognized as a diagnostic method in modern medicine, it has been considered as a therapeutic approach in the recent years.Conclusion: According to the findings of the reviewed studies, enema is a major therapeutic focus in complementary medicine, part of which has been confirmed in the recent studies. Given the low side effects and high success rate of this treatment, it can be used as a supplemental therapy for the management of poisoning, febrile seizures, prolonged functional constipation, and chronic kidney disease, as well as the prevention of swelling. However, this theory requires further investigation and targeted clinical trials. This method has been

  2. - Synonymy in the Translation Equivalent Paradigms of a Standard ...

    African Journals Online (AJOL)

    directional dictionaries". ... Examples from Groot Woordeboek / Major Dictionary, ... Examples of such divergence which may require labelling (or even more ..... Selection and Presentation of Ready Equivalents in a Translation Dictionary.

  3. Can quantum probes satisfy the weak equivalence principle?

    International Nuclear Information System (INIS)

    Seveso, Luigi; Paris, Matteo G.A.

    2017-01-01

    We address the question whether quantum probes in a gravitational field can be considered as test particles obeying the weak equivalence principle (WEP). A formulation of the WEP is proposed which applies also in the quantum regime, while maintaining the physical content of its classical counterpart. Such formulation requires the introduction of a gravitational field not to modify the Fisher information about the mass of a freely-falling probe, extractable through measurements of its position. We discover that, while in a uniform field quantum probes satisfy our formulation of the WEP exactly, gravity gradients can encode nontrivial information about the particle’s mass in its wavefunction, leading to violations of the WEP. - Highlights: • Can quantum probes under gravity be approximated as test-bodies? • A formulation of the weak equivalence principle for quantum probes is proposed. • Quantum probes are found to violate it as a matter of principle.

  4. Can quantum probes satisfy the weak equivalence principle?

    Energy Technology Data Exchange (ETDEWEB)

    Seveso, Luigi, E-mail: luigi.seveso@unimi.it [Quantum Technology Lab, Dipartimento di Fisica, Università degli Studi di Milano, I-20133 Milano (Italy); Paris, Matteo G.A. [Quantum Technology Lab, Dipartimento di Fisica, Università degli Studi di Milano, I-20133 Milano (Italy); INFN, Sezione di Milano, I-20133 Milano (Italy)

    2017-05-15

    We address the question whether quantum probes in a gravitational field can be considered as test particles obeying the weak equivalence principle (WEP). A formulation of the WEP is proposed which applies also in the quantum regime, while maintaining the physical content of its classical counterpart. Such formulation requires the introduction of a gravitational field not to modify the Fisher information about the mass of a freely-falling probe, extractable through measurements of its position. We discover that, while in a uniform field quantum probes satisfy our formulation of the WEP exactly, gravity gradients can encode nontrivial information about the particle’s mass in its wavefunction, leading to violations of the WEP. - Highlights: • Can quantum probes under gravity be approximated as test-bodies? • A formulation of the weak equivalence principle for quantum probes is proposed. • Quantum probes are found to violate it as a matter of principle.

  5. Therapeutic Responses of Psychopathic Sexual Offenders: Treatment Attrition, Therapeutic Change, and Long-Term Recidivism

    Science.gov (United States)

    Olver, Mark E.; Wong, Stephen C. P.

    2009-01-01

    The authors examined the therapeutic responses of psychopathic sex offenders (greater than or equal to 25 Psychopathy Checklist-Revised; PCL-R) in terms of treatment dropout and therapeutic change, as well as sexual and violent recidivism over a 10-year follow-up among 156 federally incarcerated sex offenders treated in a high-intensity inpatient…

  6. New concepts in therapeutic photomedicine: photochemistry, optical targeting and the therapeutic window

    International Nuclear Information System (INIS)

    Parrish, J.A.

    1981-01-01

    Advances in optics technology, synthetic photochemistry, and the science of photobiology make it possible to think beyond phototherapy and photochemotherapy which is dependent on direct photochemical alteration of metabolites or direct phototoxic insult to cells. This report discusses another gender of photomedicine therapy which includes in vivo photoactivation of medicines, photon-dependent drug delivery, and manipulation of host and exposure source to maximize therapeutic index. These therapeutic manipulations are made possible because the skin is highly overperfused and because non-ionizing electromagnetic radiation that enters skin and blood has adequate photon energy to cause electronic excitation. Radiation of 320-800 nm is not very directly phototoxic, is absorbed by a variety of relatively nontoxic photolabile molecules and has an internal dosimetric depth profile. This radiation can therefore be used to activate, deactivate, bind, release or biotransform medications in vivo in skin or other organs. The photochemist, synthetic chemist and photobiologist can collaborate to significantly increase therapeutic possibilities

  7. Oncolytic Viruses: Therapeutics With an Identity Crisis

    Directory of Open Access Journals (Sweden)

    Caroline J. Breitbach

    2016-07-01

    Full Text Available Oncolytic viruses (OV are replicating viral therapeutics for the treatment of cancer and have been in laboratory development for about twenty years. Recently, the FDA approved Imlygic, a herpes virus based therapeutic for the treatment of melanoma and thus OVs have entered a new era where they are a weapon in the armament of the oncologist. OVs are unique therapeutics with multiple mechanisms of therapeutic activity. The exact path for their development and eventual uptake by pharmaceutical companies is somewhat clouded by an uncertain identity. Are they vaccines, tumour lysing therapeutics, inducers of innate immunity, gene therapy vectors, anti-vascular agents or all of the above? Should they be developed as stand-alone loco-regional therapeutics, systemically delivered tumour hunters or immune modulators best tested as combination therapeutics? We summarize data here supporting the idea, depending upon the virus, that OVs can be any or all of these things. Pursuing a “one-size fits all” approach is counter-productive to their clinical development and instead as a field we should build on the strengths of individual virus platforms.

  8. Idiomaticity of English Business Terms and Their Equivalents in Lithuanian

    Directory of Open Access Journals (Sweden)

    Pavel Skorupa

    2011-04-01

    Full Text Available The paper presents the survey of idiomatic English business terms and their Lithuanian equivalents. The study was based on the theory of idioms and idiomaticity, highlighting the idea that idiomaticity can affect single words, word combinations, and longer text passages. Idiomatic business terms were taken from different English and Lithuanian general and special dictionaries, course books, as well as business texts. The analyzed terms were classified into distinct groups according to their meaning. The key problem encountered was the lack of Lithuanian translation equivalents to certain idiomatic English business terms. Possible Lithuanian translation was provided.

  9. Lead Equivalent Thickness Measurement for Mixed Compositions of Barium Plaster Block

    International Nuclear Information System (INIS)

    Norriza Mohd Isa; Muhammad Jamal Muhammad Isa; Nur Shahriza Zainuddin; Mohd Khairusalih Md Zin; Shahrul Azlan Azizan

    2016-01-01

    Measurement of lead equivalent thickness for ionizing radiation exposure room wall shall be performed as stated in Malaysian Standard MS 838. A few numbers of sample blocks with different mixture of barium plaster compositions based and varies certain thickness as a shielding material for exposure room wall belong to a local company were tested by using Cs-137, Co-60 and Am-241 with different activities . Radiations passed through the samples were detected with calibrated survey meter. The distance between radiation source and the detector is about 40 cm. Lead uniformity test on the samples was also determined at three labeled points on the samples. Lead equivalent thicknesses for the samples were evaluated based on a calibration graph that was plotted with lead sheets and with the radiation sources. Results shown that lead equivalent thickness for the samples with same actual physical thickness represent different values for different sources. (author)

  10. Antipsychotic dose equivalents and dose-years: a standardized method for comparing exposure to different drugs.

    Science.gov (United States)

    Andreasen, Nancy C; Pressler, Marcus; Nopoulos, Peg; Miller, Del; Ho, Beng-Choon

    2010-02-01

    A standardized quantitative method for comparing dosages of different drugs is a useful tool for designing clinical trials and for examining the effects of long-term medication side effects such as tardive dyskinesia. Such a method requires establishing dose equivalents. An expert consensus group has published charts of equivalent doses for various antipsychotic medications for first- and second-generation medications. These charts were used in this study. Regression was used to compare each drug in the experts' charts to chlorpromazine and haloperidol and to create formulas for each relationship. The formulas were solved for chlorpromazine 100 mg and haloperidol 2 mg to derive new chlorpromazine and haloperidol equivalents. The formulas were incorporated into our definition of dose-years such that 100 mg/day of chlorpromazine equivalent or 2 mg/day of haloperidol equivalent taken for 1 year is equal to one dose-year. All comparisons to chlorpromazine and haloperidol were highly linear with R(2) values greater than .9. A power transformation further improved linearity. By deriving a unique formula that converts doses to chlorpromazine or haloperidol equivalents, we can compare otherwise dissimilar drugs. These equivalents can be multiplied by the time an individual has been on a given dose to derive a cumulative value measured in dose-years in the form of (chlorpromazine equivalent in mg) x (time on dose measured in years). After each dose has been converted to dose-years, the results can be summed to provide a cumulative quantitative measure of lifetime exposure. Copyright 2010 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.

  11. Planck Constant Determination from Power Equivalence

    Science.gov (United States)

    Newell, David B.

    2000-04-01

    Equating mechanical to electrical power links the kilogram, the meter, and the second to the practical realizations of the ohm and the volt derived from the quantum Hall and the Josephson effects, yielding an SI determination of the Planck constant. The NIST watt balance uses this power equivalence principle, and in 1998 measured the Planck constant with a combined relative standard uncertainty of 8.7 x 10-8, the most accurate determination to date. The next generation of the NIST watt balance is now being assembled. Modification to the experimental facilities have been made to reduce the uncertainty components from vibrations and electromagnetic interference. A vacuum chamber has been installed to reduce the uncertainty components associated with performing the experiment in air. Most of the apparatus is in place and diagnostic testing of the balance should begin this year. Once a combined relative standard uncertainty of one part in 10-8 has been reached, the power equivalence principle can be used to monitor the possible drift in the artifact mass standard, the kilogram, and provide an accurate alternative definition of mass in terms of fundamental constants. *Electricity Division, Electronics and Electrical Engineering Laboratory, Technology Administration, U.S. Department of Commerce. Contribution of the National Institute of Standards and Technology, not subject to copyright in the U.S.

  12. Expanding the Interaction Equivalency Theorem

    Directory of Open Access Journals (Sweden)

    Brenda Cecilia Padilla Rodriguez

    2015-06-01

    Full Text Available Although interaction is recognised as a key element for learning, its incorporation in online courses can be challenging. The interaction equivalency theorem provides guidelines: Meaningful learning can be supported as long as one of three types of interactions (learner-content, learner-teacher and learner-learner is present at a high level. This study sought to apply this theorem to the corporate sector, and to expand it to include other indicators of course effectiveness: satisfaction, knowledge transfer, business results and return on expectations. A large Mexican organisation participated in this research, with 146 learners, 30 teachers and 3 academic assistants. Three versions of an online course were designed, each emphasising a different type of interaction. Data were collected through surveys, exams, observations, activity logs, think aloud protocols and sales records. All course versions yielded high levels of effectiveness, in terms of satisfaction, learning and return on expectations. Yet, course design did not dictate the types of interactions in which students engaged within the courses. Findings suggest that the interaction equivalency theorem can be reformulated as follows: In corporate settings, an online course can be effective in terms of satisfaction, learning, knowledge transfer, business results and return on expectations, as long as (a at least one of three types of interaction (learner-content, learner-teacher or learner-learner features prominently in the design of the course, and (b course delivery is consistent with the chosen type of interaction. Focusing on only one type of interaction carries a high risk of confusion, disengagement or missed learning opportunities, which can be managed by incorporating other forms of interactions.

  13. Equivalent circuit of a coaxial-line-based nozzleless microwave 915 MHz plasma source

    International Nuclear Information System (INIS)

    Miotk, R; Jasiński, M; Mizeraczyk, J

    2016-01-01

    This paper presents a new concept of an equivalent circuit of a microwave plasma source (MPS) used for gas treatment. The novelty of presented investigations is the use of the Weissfloch circuit as equivalent of an area of waveguide discontinuity in the MPS which is a result of entering a coaxial-line structure. Furthermore, in this area the microwave discharge is generated. Verification of the proposed method was carried out. The proposed equivalent circuit enabled calculating the MPS tuning characteristics and comparing them with those measured experimentally. This process allowed us to determine the impedance Z_P ofplasma in the MPS. (paper)

  14. Cardinal Equivalence of Small Number in Young Children.

    Science.gov (United States)

    Kingma, J.; Roelinga, U.

    1982-01-01

    Children completed three types of equivalent cardination tasks which assessed the influence of different stimulus configurations (linear, linear-nonlinear, and nonlinear), and density of object spacing. Prior results reported by Siegel, Brainerd, and Gelman and Gallistel were not replicated. Implications for understanding cardination concept…

  15. Equivalent Circuit Modeling of a Rotary Piezoelectric Motor

    DEFF Research Database (Denmark)

    El, Ghouti N.; Helbo, Jan

    2000-01-01

    In this paper, an enhanced equivalent circuit model of a rotary traveling wave piezoelectric ultrasonic motor "shinsei type USR60" is derived. The modeling is performed on the basis of an empirical approach combined with the electrical network method and some simplification assumptions about the ...

  16. F-sigma equivalence relations and Laver forcing

    Czech Academy of Sciences Publication Activity Database

    Doucha, Michal

    2014-01-01

    Roč. 79, č. 2 (2014), s. 644-653 ISSN 0022-4812 R&D Projects: GA AV ČR IAA100190902 Institutional support: RVO:67985840 Keywords : Borel equivalence relations * Laver ideal * canonical Ramsey theorem Subject RIV: BA - General Mathematics Impact factor: 0.541, year: 2014 http://journals.cambridge.org/action/displayAbstract?fromPage=online&aid=9287231&fileId=S0022481213000327

  17. Therapeutic Sleep for Traumatic Brain Injury

    Science.gov (United States)

    2017-06-01

    AWARD NUMBER: W81XWH-16-1-0166 TITLE: Therapeutic Sleep for Traumatic Brain Injury PRINCIPAL INVESTIGATOR: Ravi Allada CONTRACTING...1. REPORT DATE June 2017 2. REPORT TYPE Annual 3. DATES COVERED 1June2016 - 31May2017 4. TITLE AND SUBTITLE Therapeutic Sleep for Traumatic Brain ...proposal will test the hypothesis that correcting sleep disorders can have a therapeutic effect onTraumatic Brain Injury (TBI) The majority of TBI

  18. Analyzing the Measurement Equivalence of a Translated Test in a Statewide Assessment Program

    Directory of Open Access Journals (Sweden)

    Jorge Carvajal-Espinoza

    2016-09-01

    Full Text Available When tests are translated into one or more languages, the question of the equivalence of items across language forms arises. This equivalence can be assessed at the scale level by means of a multiple group confirmatory factor analysis (CFA in the context of structural equation modeling. This study examined the measurement equivalence of a Spanish translated version of a statewide Mathematics test originally constructed in English by using a multi-group CFA approach. The study used samples of native speakers of the target language of the translation taking the test in both the source and target language, specifically Hispanics taking the test in English and Spanish. Test items were grouped in twelve facet-representative parcels. The parceling was accomplished by grouping items that corresponded to similar content and computing an average for each parcel. Four models were fitted to examine the equivalence of the test across groups. The multi-group CFA fixed factor loadings across groups and results supported the equivalence of the two language versions (English and Spanish of the test. The statistical techniques implemented in this study can also be used to address the performance on a test based on dichotomous or dichotomized variables such as gender, socioeconomic status, geographic location and other variables of interest.

  19. Adverse events and therapeutic efficacy associated with TACE for hepatocellular carcinoma with a miriplatin-lipiodol suspension in comparison with a cisplatin-lipiodol suspension

    International Nuclear Information System (INIS)

    Araki, Takuji; Okada, Taiki; Kimura, Kazufumi; Sawada, Eiichi; Sano, Katushiro; Araki, Tsutomu

    2012-01-01

    The aim of this study was to evaluate the short-term adverse events and therapeutic efficacy of transcatheter arterial chemoembolization (TACE) for hepatocellular carcinoma (HCC) with a miriplatin-lipiodol suspension in comparison with a cisplatin-lipiodol suspension. Of patients who underwent TACE for unresectable HCCs in 2009 and 2010, twenty-nine and twenty-seven patients underwent TACE using cisplatin-lipiodol suspension (C-LS) and miriplatin-lipiodol suspension (M-LS), respectively. Adverse events of fever, pain, nausea, anorexia, elevation of aspartate aminotransferase (AST), total bilirubin, creatinine and a decrease in platelet count were evaluated by the National Cancer Institute Common Toxicity Criteria Ver.4. to compare the C-LS and M-LS groups. The short-term therapeutic efficacy of both groups was evaluated by the treatment effect (TE) on the CT images three months after TACE according to the General Rules for the Clinical and Pathological Study of Primary Liver Cancer (the 5th edition, Revised Version). With regard to the adverse events, the M-LS group had significantly less fever and anorexia than the C-LS group. No critical adverse events were observed in either group. The therapeutic efficacy was not significantly different between the groups. TACE with M-LS had fewer adverse events than TACE with C-LS, but neither TACE led to any critical adverse events. The short-term therapeutic efficacy of TACE with M-LS was equivalent to that of TACE with C-LS. (author)

  20. Money and bonds: an equivalence theorem

    OpenAIRE

    Narayana R. Kocherlakota

    2007-01-01

    This paper considers four models in which immortal agents face idiosyncratic shocks and trade only a single risk-free asset over time. The four models specify this single asset to be private bonds, public bonds, public money, or private money respectively. I prove that, given an equilibrium in one of these economies, it is possible to pick the exogenous elements in the other three economies so that there is an outcome-equivalent equilibrium in each of them. (The term ?exogenous variables? ref...

  1. New equivalent-electrical circuit model and a practical measurement method for human body impedance.

    Science.gov (United States)

    Chinen, Koyu; Kinjo, Ichiko; Zamami, Aki; Irei, Kotoyo; Nagayama, Kanako

    2015-01-01

    Human body impedance analysis is an effective tool to extract electrical information from tissues in the human body. This paper presents a new measurement method of impedance using armpit electrode and a new equivalent circuit model for the human body. The lowest impedance was measured by using an LCR meter and six electrodes including armpit electrodes. The electrical equivalent circuit model for the cell consists of resistance R and capacitance C. The R represents electrical resistance of the liquid of the inside and outside of the cell, and the C represents high frequency conductance of the cell membrane. We propose an equivalent circuit model which consists of five parallel high frequency-passing CR circuits. The proposed equivalent circuit represents alpha distribution in the impedance measured at a lower frequency range due to ion current of the outside of the cell, and beta distribution at a high frequency range due to the cell membrane and the liquid inside cell. The calculated values by using the proposed equivalent circuit model were consistent with the measured values for the human body impedance.

  2. Derived equivalences for group rings

    CERN Document Server

    König, Steffen

    1998-01-01

    A self-contained introduction is given to J. Rickard's Morita theory for derived module categories and its recent applications in representation theory of finite groups. In particular, Broué's conjecture is discussed, giving a structural explanation for relations between the p-modular character table of a finite group and that of its "p-local structure". The book is addressed to researchers or graduate students and can serve as material for a seminar. It surveys the current state of the field, and it also provides a "user's guide" to derived equivalences and tilting complexes. Results and proofs are presented in the generality needed for group theoretic applications.

  3. Transportability of Equivalence-Based Programmed Instruction: Efficacy and Efficiency in a College Classroom

    Science.gov (United States)

    Fienup, Daniel M.; Critchfield, Thomas S.

    2011-01-01

    College students in a psychology research-methods course learned concepts related to inferential statistics and hypothesis decision making. One group received equivalence-based instruction on conditional discriminations that were expected to promote the emergence of many untaught, academically useful abilities (i.e., stimulus equivalence group). A…

  4. Research on the equivalent circuit model of a circular flexural-vibration-research on the equivalent circuit model of a circular flexural-vibration-mode piezoelectric transformer with moderate thickness.

    Science.gov (United States)

    Huang, Yihua; Huang, Wenjin; Wang, Qinglei; Su, Xujian

    2013-07-01

    The equivalent circuit model of a piezoelectric transformer is useful in designing and optimizing the related driving circuits. Based on previous work, an equivalent circuit model for a circular flexural-vibration-mode piezoelectric transformer with moderate thickness is proposed and validated by finite element analysis. The input impedance, voltage gain, and efficiency of the transformer are determined through computation. The basic behaviors of the transformer are shown by numerical results.

  5. Measurement equivalence of patient safety climate in Chinese hospitals: can we compare across physicians and nurses?

    Science.gov (United States)

    Zhu, Junya

    2018-06-11

    Self-report instruments have been widely used to better understand variations in patient safety climate between physicians and nurses. Research is needed to determine whether differences in patient safety climate reflect true differences in the underlying concepts. This is known as measurement equivalence, which is a prerequisite for meaningful group comparisons. This study aims to examine the degree of measurement equivalence of the responses to a patient safety climate survey of Chinese hospitals and to demonstrate how the measurement equivalence method can be applied to self-report climate surveys for patient safety research. Using data from the Chinese Hospital Survey of Patient Safety Climate from six Chinese hospitals in 2011, we constructed two groups: physicians and nurses (346 per group). We used multiple-group confirmatory factor analyses to examine progressively more stringent restrictions for measurement equivalence. We identified weak factorial equivalence across the two groups. Strong factorial equivalence was found for Organizational Learning, Unit Management Support for Safety, Adequacy of Safety Arrangements, Institutional Commitment to Safety, Error Reporting and Teamwork. Strong factorial equivalence, however, was not found for Safety System, Communication and Peer Support and Staffing. Nevertheless, further analyses suggested that nonequivalence did not meaningfully affect the conclusions regarding physician-nurse differences in patient safety climate. Our results provide evidence of at least partial equivalence of the survey responses between nurses and physicians, supporting mean comparisons of its constructs between the two groups. The measurement equivalence approach is essential to ensure that conclusions about group differences are valid.

  6. A Brief Talk of Functional Equivalence Used in Chinese Translation of English Lyrics

    Institute of Scientific and Technical Information of China (English)

    吴晨

    2015-01-01

    With the development of cultural exchanges between China and foreign countries,a great number of English songs,serving as one important part of cultural exchanges,have been an important part of Chinese people’s daily life. However,barriers always could be encountered in translating those lyrics into Chinese. Thus,how to realize functional equivalence between Chinese translation version and English song lyrics has been a tough target which could not be neglected. By looking at Chinese translation of English song lyrics,a study of functional equivalence used on it will be made to solve such problems,it includes the principles for producing functional equivalence and adjustment. The key to realize functional equivalence in Chinese translation of English song lyrics is,namely,to balance rhythm and tones with the style of English songs,to minimize the loss of meaning in Chinese translation version,so that Chinese music lovers would understand the meaning of English song lyrics.

  7. On the equivalence of different definitions of R-operation

    International Nuclear Information System (INIS)

    Wegrzyn, P.

    1989-01-01

    Three well-known definitions of R-operation in the BPHZ formalism are presented. The equivalence between the Zimmermann's forest formula and the factorized version of R-operation is proved. 11 refs. (author)

  8. The simulated measurements of area and personal neutron-gamma dose equivalent in the building of HWRR

    International Nuclear Information System (INIS)

    Chen Changmao; Wen Youqin; Su Jingling; Liu Shuying; Liu Nairong

    1988-01-01

    The measuring methods and results for area and personal n-γ dose equivalent in the building of HWRR of Institute of Atomic Energy were reported. The reactor operated 4440 hours during 1985, the average themal power was 11 MW. The average area n-γ dose equivalents of the basement, experimental hall, corridors and laboratories in the building were 12.2, 11.6, 0.45 and 0.23 cSv/a, respectively. The fraction of the neutron dose equivalent in any working area was less than 21%. The average personal n-γ dose equivalent to radiation workers in the building was about 0.49 cSv/a, the γ dose equivalent was a major component. The measuring methods were compared

  9. The Dynamics Of English Terminological Compound Lexemes And Their Serbian Equivalents

    Directory of Open Access Journals (Sweden)

    Dimković-Telebaković Gordana

    2014-03-01

    Full Text Available This paper discusses the conceptual dynamicity of English compound lexemes and their Serbian equivalents as reflected in compound lexemes in traffic engineering. The morphological structure and semantics of compound lexemes are considered, as well as strategies for translating English metaphorical compound lexemes into Serbian. The analysis reveals that Serbian cannot cope with the dynamic nature of traffic engineering terminology in English, and that Anglicisms, synonyms of different polysemous terms and vague conceptual determinations are characteristic of Serbian terminological equivalents

  10. Martensitic transformation in SUS304 steels with the same Ni equivalent

    International Nuclear Information System (INIS)

    Ueda, T.; Okino, Y.; Takahashi, S.; Echigoya, J.; Kamada, Y.

    2003-01-01

    The behavior of martensitic transformation due to plastic deformation at room temperature was investigated in SUS304 austenitic stainless steels with the same nickel equivalent. The absolute volume of the martensitic phase was obtained by saturation magnetization. We discuss the shapes of the martensitic phase caused by different values of coercive force. Martensitic transformation depends on the applied stress but is independent of nickel content with same nickel equivalent. We investigated applications to nondestructive testing on the basis of the present study. (author)

  11. Equivalence-based instruction of academic skills: Application to adolescents with autism.

    Science.gov (United States)

    Stanley, Caleb R; Belisle, Jordan; Dixon, Mark R

    2018-04-01

    This study evaluated the efficacy of three equivalence-based instruction procedures on the acquisition of novel academic skills by 3 adolescents diagnosed with autism in a school setting. The skills targeted for instruction were related to topics in history, science, and mathematics, and were taught using different training structures from the PEAK-E curriculum. All participants demonstrated mastery of the trained relations and the tested derived relations following all variants of equivalence-based instruction. © 2018 Society for the Experimental Analysis of Behavior.

  12. TORREFACTION OF CELLULOSE: VALIDITY AND LIMITATION OF THE TEMPERATURE/DURATION EQUIVALENCE

    OpenAIRE

    Lv , Pin; Almeida , Giana; Perré , Patrick

    2012-01-01

    During torrefaction of biomass, equivalence between temperature and residence time is often reported, either in terms of the loss of mass or the alternation of properties. The present work proposes a rigorous investigation of this equivalence. Cellulose, as the main lignocellulosic biomass component, was treated under mild pyrolysis for 48 hours. Several couples of T-D (temperature-duration) points were selected from TGA curves to obtain mass losses of 11.6%, 25%, 50%, 74.4%, and 86.7%. The c...

  13. Evidence Based Digoxin Therapeutic Monitoring - A Lower and Narrower Therapeutic Range

    Directory of Open Access Journals (Sweden)

    Amine BENLMOUDEN

    2016-06-01

    Full Text Available Cardiac glycosides have been used for congestive heart failure and certain cardiac arrhythmias for more than 200 years. Despite the introduction of a variety of new classes of drugs for the management of heart failure, specifically angiotensin-converting enzyme (ACE inhibitors, b-adrenergic antagonists (bblockers, and the aldosterone antagonist spironolactone, digoxin continues to have an important role in long-term outpatient management. However, a narrow margin exists between therapeutic and toxic doses of digoxin, resulting in a high incidence of digoxin toxicity in clinical practice.A wide variety of placebo-controlled clinical trials have unequivocally shown that treatment with digoxin can improve symptoms, quality of life, and exercise tolerance in patients with mild, moderate, or severe heart failure. The clinical relevance of digoxin therapeutic monitoring is also proved but the SDC (Serum Digoxin Conentrations required for optimal clinical efficacy and acceptable toxicity remains controversial. In the last years, international guidelines recommend 1.2 ng/mL as acceptable high level.In this bibliographic synthesis, we aim to collect pertinent informations from MedLine database about exposure-effect relationship in order to assess the evidence level scientific of new digoxin therapeutic monitoring. 

  14. A method to obtain new cross-sections transport equivalent

    International Nuclear Information System (INIS)

    Palmiotti, G.

    1988-01-01

    We present a method, that allows the calculation, by the mean of variational principle, of equivalent cross-sections in order to take into account the transport and mesh size effects on reactivity variation calculations. The method validation has been made in two and three dimensions geometries. The reactivity variations calculated in three dimensional hexagonal geometry with seven points by subassembly using two sets of equivalent cross-sections for control rods are in a very good agreement with the ones of a transport, extrapolated to zero mesh size, calculation. The difficulty encountered in obtaining a good flux distribution has lead to the utilisation of a single set of equivalent cross-sections calculated by starting from an appropriated R-Z model that allows to take into account also the axial transport effects for the control rod followers. The global results in reactivity variations are still satisfactory with a good performance for the flux distribution. The main interest of the proposed method is the possibility to simulate a full 3D transport calculation, with fine mesh size, using a 3D diffusion code, with a larger mesh size. The results obtained should be affected by uncertainties, which do not exceed ± 4% for a large LMFBR control rod worth and for very different rod configurations. This uncertainty is by far smaller than the experimental uncertainties. (author). 5 refs, 8 figs, 9 tabs

  15. Integrable topological billiards and equivalent dynamical systems

    Science.gov (United States)

    Vedyushkina, V. V.; Fomenko, A. T.

    2017-08-01

    We consider several topological integrable billiards and prove that they are Liouville equivalent to many systems of rigid body dynamics. The proof uses the Fomenko-Zieschang theory of invariants of integrable systems. We study billiards bounded by arcs of confocal quadrics and their generalizations, generalized billiards, where the motion occurs on a locally planar surface obtained by gluing several planar domains isometrically along their boundaries, which are arcs of confocal quadrics. We describe two new classes of integrable billiards bounded by arcs of confocal quadrics, namely, non-compact billiards and generalized billiards obtained by gluing planar billiards along non-convex parts of their boundaries. We completely classify non-compact billiards bounded by arcs of confocal quadrics and study their topology using the Fomenko invariants that describe the bifurcations of singular leaves of the additional integral. We study the topology of isoenergy surfaces for some non-convex generalized billiards. It turns out that they possess exotic Liouville foliations: the integral trajectories of the billiard that lie on some singular leaves admit no continuous extension. Such billiards appear to be leafwise equivalent to billiards bounded by arcs of confocal quadrics in the Minkowski metric.

  16. Twisted conformal field theories and Morita equivalence

    Energy Technology Data Exchange (ETDEWEB)

    Marotta, Vincenzo [Dipartimento di Scienze Fisiche, Universita di Napoli ' Federico II' and INFN, Sezione di Napoli, Compl. universitario M. Sant' Angelo, Via Cinthia, 80126 Napoli (Italy); Naddeo, Adele [CNISM, Unita di Ricerca di Salerno and Dipartimento di Fisica ' E.R. Caianiello' , Universita degli Studi di Salerno, Via Salvador Allende, 84081 Baronissi (Italy); Dipartimento di Scienze Fisiche, Universita di Napoli ' Federico II' , Compl. universitario M. Sant' Angelo, Via Cinthia, 80126 Napoli (Italy)], E-mail: adelenaddeo@yahoo.it

    2009-04-01

    The Morita equivalence for field theories on noncommutative two-tori is analysed in detail for rational values of the noncommutativity parameter {theta} (in appropriate units): an isomorphism is established between an Abelian noncommutative field theory (NCFT) and a non-Abelian theory of twisted fields on ordinary space. We focus on a particular conformal field theory (CFT), the one obtained by means of the m-reduction procedure [V. Marotta, J. Phys. A 26 (1993) 3481; V. Marotta, Mod. Phys. Lett. A 13 (1998) 853; V. Marotta, Nucl. Phys. B 527 (1998) 717; V. Marotta, A. Sciarrino, Mod. Phys. Lett. A 13 (1998) 2863], and show that it is the Morita equivalent of a NCFT. Finally, the whole m-reduction procedure is shown to be the image in the ordinary space of the Morita duality. An application to the physics of a quantum Hall fluid at Jain fillings {nu}=m/(2pm+1) is explicitly discussed in order to further elucidate such a correspondence and to clarify its role in the physics of strongly correlated systems. A new picture emerges, which is very different from the existing relationships between noncommutativity and many body systems [A.P. Polychronakos, arXiv: 0706.1095].

  17. Dose equivalent distribution during occupational exposure in oncology

    International Nuclear Information System (INIS)

    Marco H, J.

    1996-01-01

    In this work are presented the results of the radiological surveillance of occupationally exposed workers at the National Institute of Oncology and Radiology during 26 years. The incidence of the equivalent dose in the personal working with radiant sources and radioactive substances in areas of x rays diagnostic, teletherapy, brachytherapy, nuclear medicine and biomedical research was showed. The employed dosimetric system makes use of ORWO RD3/RD4 monitoring film with copper and lead filters inside a plastic cassette manufactured in Cuba. The experimental method is supported by the optical densitometric analysis of films together with a set of standard film calibrated in standard X and gamma photon beams by means of a secondary standard dosimeter, type NPL. Statistics show that except those workings with radium-226, manual brachytherapy or Mo-99/Tc-99 generator elution, the equivalent dose distribution in our workers has been kept in regions well down the annual permissible limit. (authors). 6 refs., 3 tabs

  18. Tests of the equivalence principle with neutral kaons

    CERN Document Server

    Apostolakis, Alcibiades J; Backenstoss, Gerhard; Bargassa, P; Behnke, O; Benelli, A; Bertin, V; Blanc, F; Bloch, P; Carlson, P J; Carroll, M; Cawley, E; Chardin, G; Chertok, M B; Danielsson, M; Dejardin, M; Derré, J; Ealet, A; Eleftheriadis, C; Faravel, L; Fetscher, W; Fidecaro, Maria; Filipcic, A; Francis, D; Fry, J; Gabathuler, Erwin; Gamet, R; Gerber, H J; Go, A; Haselden, A; Hayman, P J; Henry-Coüannier, F; Hollander, R W; Jon-And, K; Kettle, P R; Kokkas, P; Kreuger, R; Le Gac, R; Leimgruber, F; Mandic, I; Manthos, N; Marel, Gérard; Mikuz, M; Miller, J; Montanet, François; Müller, A; Nakada, Tatsuya; Pagels, B; Papadopoulos, I M; Pavlopoulos, P; Polivka, G; Rickenbach, R; Roberts, B L; Ruf, T; Sakelliou, L; Schäfer, M; Schaller, L A; Schietinger, T; Schopper, A; Tauscher, Ludwig; Thibault, C; Touchard, F; Touramanis, C; van Eijk, C W E; Vlachos, S; Weber, P; Wigger, O; Wolter, M; Zavrtanik, D; Zimmerman, D; Ellis, Jonathan Richard; Mavromatos, Nikolaos E; Nanopoulos, Dimitri V

    1999-01-01

    We test the Principle of Equivalence for particles and antiparticles, using CPLEAR data on tagged Pkao and Pkab decays into $pi^+ pi^-$. For the first time, we search for possible annual, monthly and diurnal modulations of the observables $|eta_{+-}|$ and $phi _{+-}$, that could be correlated with variations in astrophysical potentials. Within the accuracy of CPLEAR, the measured values of $|eta _{+-}|$ and $phi _{+-}$ are found not to be correlated with changes of the gravitational potential. We analyze data assuming effective scalar, vector and tensor interactions, and we conclude that the Principle of Equivalence between particles and antiparticles holds to a level of $6.5$, $4.3$ and $1.8 imes 10^{-9}$, respectively, for scalar, vector and tensor potentials originating from the Sun with a range much greater than the distance Earth-Sun. We also study energy-dependent effects that might arise from vector or tensor interactions. Finally, we compile upper limits on the gravitational coupling difference betwee...

  19. Equivalent Circuit for Magnetoelectric Read and Write Operations

    Science.gov (United States)

    Camsari, Kerem Y.; Faria, Rafatul; Hassan, Orchi; Sutton, Brian M.; Datta, Supriyo

    2018-04-01

    We describe an equivalent circuit model applicable to a wide variety of magnetoelectric phenomena and use spice simulations to benchmark this model against experimental data. We use this model to suggest a different mode of operation where the 1 and 0 states are represented not by states with net magnetization (like mx , my, or mz) but by different easy axes, quantitatively described by (mx2-my2), which switches from 0 to 1 through the write voltage. This change is directly detected as a read signal through the inverse effect. The use of (mx2-my2) to represent a bit is a radical departure from the standard convention of using the magnetization (m ) to represent information. We then show how the equivalent circuit can be used to build a device exhibiting tunable randomness and suggest possibilities for extending it to nonvolatile memory with read and write capabilities, without the use of external magnetic fields or magnetic tunnel junctions.

  20. Negotiating for more: the multiple equivalent simultaneous offer.

    Science.gov (United States)

    Heller, Richard E

    2014-02-01

    Whether a doctor, professional baseball manager, or a politician, having successful negotiation skills is a critical part of being a leader. Building upon prior journal articles on negotiation strategy, the author presents the concept of the multiple equivalent simultaneous offer (MESO). The concept of a MESO is straightforward: as opposed to making a single offer, make multiple offers with several variables. Each offer alters the different variables, such that the end result of each offer is equivalent from the perspective of the party making the offer. Research has found several advantages to the use of MESOs. For example, using MESOs, an offer was more likely to be accepted, and the counterparty was more likely to be satisfied with the negotiated deal. Additional benefits have been documented as well, underscoring why a prepared radiology business leader should understand the theory and practice of MESO. Copyright © 2014 American College of Radiology. Published by Elsevier Inc. All rights reserved.