WorldWideScience

Sample records for thallium-201 single-photon emission

  1. Indium-111 antimyosin antibody imaging and thallium-201 imaging. A comparative myocardial scintigraphic study using single-photon emission computed tomography in patients with myocarditis and dilated cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Takehiko; Matsumori, Akira; Nohara, Ryuji; Konishi, Junji; Sasayama, Shigetake [Kyoto Univ. (Japan). Faculty of Medicine; Tamaki, Nagara

    1997-10-01

    Indium-111 antimyosin antibody imaging (a tracer of myocardial necrosis) and thallium-201 imaging (a tracer of myocardial perfusion) were compared in patients with myocarditis and dilated cardiomyopathy. The distribution of each tracer and antimyosin/thallium-201 overlapping were evaluated with single-photon emission computed tomography (SPECT). Scintigraphic data were classified into 5 patterns according to the distribution of both images and were compared with histologic findings of endomyocardial biopsy: AM-D, intense and diffuse antimyosin uptake and no perfusion abnormality (active myocarditis); AM-L, localized antimyosin uptake and no perfusion abnormality (active myocarditis); HM, no antimyosin uptake with or without perfusion abnormality (healed myocarditis); DCM-NH, diffuse antimyosin uptake and inhomogeneous thallium-201 uptake (dilated cardiomyopathy); DCM-PD, diffuse or localized antimyosin uptake and myocardial perfusion defect(s) (dilated cardiomyopathy). Patients with dilated-phase hypertrophic cardiomyopathy were frequently found in the DCM-PD group. Taken together, comparative antimyosin/thallium-201 SPECT images are useful for evaluating the activity of myocarditis and ongoing myocardial damage even in areas with no perfusion in patients with dilated cardiomyopathy. (author)

  2. Comparison of glucose-insulin-thallium-201 infusion single photon emission computed tomography (SPECT), stress-redistribution-reinjection thallium-201 SPECT and low dose dobutamine echocardiography for prediction of reversible dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Sakamoto, Hiroki; Kondo, Makoto; Motohiro, Masayuki; Usami, Satoru [Shimada Municipal Hospital, Shizuoka (Japan)

    2001-12-01

    The usefulness of glucose-insulin-thallium-201 (GI-Tl) infusion single photon emission computed tomography (SPECT) in predicting reversible dysfunction has not been evaluated, so the present study recruited 20 patients with regional ischemic dysfunction for investigation. All patients underwent GI-Tl SPECT, post-stress Tl reinjection imaging and low dose dobutamine echocardiography. The diagnostic accuracy of these 3 techniques in predicting functional recovery was evaluated by receiver operating characteristic (ROC) analysis. In segments with functional recovery, regional Tl activities of GI-Tl SPECT were significantly higher than those of reinjection imaging (p<0.05), although there were no significant differences in segments without recovery. The area under the ROC curve for GI-Tl SPECT (0.75{+-}0.06) was greater than that for reinjection imaging (0.68{+-}0.07). The optimal cutoff values to identify viable myocardium were considered to be 55% of peak activity for GI-Tl SPECT and 50% for reinjection imaging. At this cutoff point, the sensitivity and specificity for detection of functional recovery were, respectively, 85% and 61% for GI-Tl SPECT, and 73% and 61% for reinjection imaging. Dobutamine echocardiography had the same sensitivity (85%), but lower specificity (48%) than GI-Tl SPECT. Continuous infusion of GI-Tl solution enhances regional Tl uptake compared with conventional post-stress reinjection imaging. This study suggests that GI-Tl SPECT is superior to reinjection imaging and dobutamine echocardiography in predicting functional recovery after ischemic left ventricular dysfunction. (author)

  3. Functional significance of myocardial perfusion defects induced by dipyridamole using thallium-201 single-photon emission computed tomography and two-dimensional echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Jain, A.; Suarez, J.; Mahmarian, J.J.; Zoghbi, W.A.; Quinones, M.A.; Verani, M.S. (Baylor College of Medicine, Houston, TX (USA))

    1990-10-01

    The mechanisms responsible for inhomogeneous myocardial blood flow after oral administration of a large dose (300 mg) of dipyridamole were assessed in 27 patients with serial thallium-201 single-photon emission computed tomography (SPECT) and simultaneous 2-dimensional echocardiograms. Myocardial tomographic images were obtained 50 minutes and 3 to 4 hours after administration of dipyridamole. Two-dimensional echocardiograms were recorded at baseline and then every 15 minutes for 60 minutes. Dipyridamole caused only a mild reduction in blood pressure (from 129 +/- 18 to 126 +/- 16 mm Hg) and a mild increase in heart rate (from 69 +/- 15 to 73 +/- 4 beats/min). Sixteen patients had perfusion defects after dipyridamole by SPECT, which underwent partial or total filling-in. Fourteen of these patients (87.5%) had either a new abnormality or further deterioration of a preexisting wall motion abnormality by 2-dimensional echocardiography, and thus were considered to have developed transient ischemia during dipyridamole administration. Ten of 11 patients (91%) with normal perfusion or fixed defects by SPECT had no further deterioration in wall motion after oral dipyridamole, and were thus considered to have no evidence of myocardial ischemia. In conclusion, most patients with transient thallium-201 defects after dipyridamole develop transient worsening of resting wall motion by 2-dimensional echocardiography, suggestive of true myocardial ischemia. Because myocardial oxygen demand, as indicated by the heart rate-blood pressure product, did not change significantly, the mechanism of myocardial ischemia in these patients is likely to be diminished regional blood flow related to a subendocardial steal induced by dipyridamole.

  4. Thallium-201 single photon emission computed tomography (SPECT) in patients with Duchenne's progressive muscular dystrophy. A histopathologic correlation study

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, Toru; Yanagisawa, Atsuo; Sakata, Konomi; Shimoyama, Katsuya; Yoshino, Hideaki; Ishikawa, Kyozo [Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine; Sakata, Hitomi; Ishihara, Tadayuki

    2001-02-01

    The pathomorphologic mechanism responsible for abnormal perfusion imaging during thallium-201 myocardial single photon emission computed tomography ({sup 201}Tl-SPECT) in patients with Duchenne's progressive muscular dystrophy (DMD) was investigated. Hearts from 7 patients with DMD were evaluated histopathologically at autopsy and the results correlated with findings on initial and delayed resting {sup 201}Tl-SPECT images. The location of segments with perfusion defects correlated with the histopathologically abnormal segments in the hearts. Both the extent and degree of myocardial fibrosis were severe, especially in the posterolateral segment of the left ventricle. Severe transmural fibrosis and severe fatty infiltration were common in segments with perfusion defects. In areas of redistribution, the degree of fibrosis appeared to be greater than in areas of normal perfusion; and intermuscular edema was prominent. Thus, the degree and extent of perfusion defects detected by {sup 201}Tl-SPECT were compatible with the histopathology. The presence of the redistribution phenomenon may indicate ongoing fibrosis. Initial and delayed resting {sup 201}Tl-SPECT images can predict the site and progress of myocardial degeneration in patients with DMD. (author)

  5. Imaging of brain tumors in AIDS patients by means of dual-isotope thallium-201 and technetium-99m sestamibi single-photon emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    De La Pena, R.C.; Ketonen, L.; Villanueva-Meyer, J. [Dept. of Radiology, Univ. of Texas, Galveston (United States)

    1998-10-01

    Our aim was to evaluate the use of dual-isotope thallium-201 (Tl) and technetium-99m sestamibi (sestamibi) simultaneous acquisition in brain single-photon emission tomography (SPET) for the differentiation between brain lymphoma and benign central nervous system (CNS) lesions in AIDS patients. Thirty-six consecutive patients with enhancing mass lesions on magnetic resonance (MR) imaging were included in the study. SPET of the brain was performed to obtain simultaneous Tl and sestamibi images. Regions-of-interest were drawn around the lesion and on the contralateral side to calculate uptake ratios. The final diagnosis was reached by pathologic findings in 17 patients and clinical and/or MR follow-up in 19 patients. Of the 36 patients, 11 had brain lymphoma, 1 glioblastoma multiforme, 15 toxoplasmosis and 9 other benign CNS lesions. Correlation between SPET and the final diagnosis revealed in 10 true-positive, 23 true-negative, 1 false-positive and 2 false-negative studies. All patients with toxoplasmosis had negative scans. A patient with a purulent infection had positive scans. Tl and sestamibi scans were concordant in every lesion. The same lesions that took up Tl were also visualized with sestamibi. However, sestamibi scans showed higher lesion-to-normal tissue uptake ratios (3.7{+-}1.8) compared with those of Tl (2.3{+-}0.8, P<0.002). Simultaneous acquisition of Tl and sestamibi can help differentiate CNS lymphoma from benign brain lesions in AIDS patients. (orig.) With 2 figs., 2 tabs., 34 refs.

  6. Iodine-123 phenylpentadecanoic acid and single photon emission computed tomography in identifying left ventricular regional metabolic abnormalities in patients with coronary heart disease: comparison with thallium-201 myocardial tomography.

    Science.gov (United States)

    Hansen, C L; Corbett, J R; Pippin, J J; Jansen, D E; Kulkarni, P V; Ugolini, V; Henderson, E; Akers, M; Buja, L M; Parkey, R W

    1988-07-01

    Iodine-123 phenylpentadecanoic acid (IPPA) is a synthetic long chain fatty acid with myocardial kinetics similar to palmitate. Two hypotheses were tested in this study. The first hypothesis was that IPPA imaging with single photon emission computed tomography (SPECT) is useful in the identification of patients with coronary artery disease. Fourteen normal volunteers (aged 27 +/- 2 years) and 33 patients (aged 54 +/- 11 years) with stable symptomatic coronary artery disease and at least one major coronary artery with luminal diameter narrowing greater than or equal to 70% were studied with symptom-limited maximal exercise testing. The IPPA (6 to 8 mCi) was injected 1 min before the termination of exercise, and tomographic imaging was performed beginning at 9 min and repeated at 40 min after the injection of IPPA. Nine of the normal volunteers and 13 of the patients had a second examination performed at rest on another day. Using the limits of normal as 2 SD from the normal mean values, 27 of the 33 patients with coronary artery disease demonstrated abnormalities in either the initial distribution or the clearance of IPPA, or both. Nineteen of the 33 patients had a maximal variation of activity distribution of greater than or equal to 25% on the 9 min IPPA images. Twenty-two of the 33 patients had a maximal variation in IPPA washout greater than 17% and 17 had a washout rate less than or equal to 2%. There was good agreement between the location of significant coronary artery stenoses and abnormalities in the initial distribution and clearance of IPPA. The second hypothesis tested was that IPPA imaging is as or more sensitive and, therefore, complementary to thallium-201 imaging in the identification of exercise-induced ischemia in patients. Twenty-five of the 33 patients underwent both thallium-201 and IPPA tomographic imaging after symptom-limited maximal exercise testing. The amount of exercise performed by each patient during both studies was similar. Twenty

  7. Significance of exercise-induced ST segment depression in patients with myocardial infarction involving the left circumflex artery. Evaluation by exercise thallium-201 myocardial single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Koitabashi, Norimichi; Toyama, Takuji; Hoshizaki, Hiroshi [Gunma Prefectural Cardiovascular Center, Maebashi (Japan)] [and others

    2000-04-01

    The significance of exercise-induced ST segment depression in patients with left circumflex artery involvement was investigated by comparing exercise electrocardiography with exercise thallium-201 single photon emission computed tomography (Tl-SPECT) and the wall motion estimated by left ventriculography. Tl-SPECT and exercise electrocardiography were simultaneously performed in 51 patients with left circumflex artery involvement (angina pectoris 30, myocardial infarction 21). In patients with myocardial infarction, exercise-induced ST depression was frequently found in the V{sub 2}, V{sub 3} and V{sub 4} leads. In patients with angina pectoris, ST depression was frequently found in the II, III, aV{sub F}, V{sub 5} and V{sub 6} leads. There was no obvious difference in the leads of ST depression in patients with myocardial infarction with ischemia and without ischemia on Tl-SPECT images. In patients with myocardial infarction, the lateral wall motion of the infarcted area evaluated by left ventriculography was more significantly impaired in the patients with ST depression than without ST depression (p<0.01). Exercise-induced ST depression in the precordial leads possibly reflects wall motion abnormality rather than ischemia in the lateral infarcted myocardium. (author)

  8. Evaluation of myocardial flow reserve using pharmacological stress thallium-201 single-photon emission computed tomography: is there a difference between total arterial off-pump coronary artery bypass grafting and conventional coronary artery bypass grafting?

    Science.gov (United States)

    Lee, Jae Won; Ryu, Sang Wan; Song, Hyun; Kim, Kyung Sun; Yang, Yu Jung; Moon, Dae Hyeuk

    2004-01-01

    The advantage of total arterial off-pump coronary bypass grafting (OPCAB) over conventional onpump coronary artery bypass grafting with 1 internal thoracic artery and veins (CCAB) in terms of myocardial flow reserve has not been studied. We studied these procedures using thallium- 201 perfusion single-photon emission computed tomography (Tl-201 perfusion SPECT). Between 1997 and 2001, 152 patients were recruited from our database (OPCAB, n = 100; CCAB, n = 52). All patients underwent pharmacological stress Tl-201 perfusion SPECT 3 to 12 months after bypass surgery. Myocardial perfusion was analyzed semiquantitatively with a 5-point scoring system in a 20-segment model (0, normal, to 4, absence of uptake). Summed stress (SSS), rest (SRS), and difference score (SDS) of the entire myocardium as well as average scores (ASS, ARS, ADS) of individual walls (anterior, septal, lateral, and inferior) were compared by Student t test as well as by repeated-measures analysis of variance with Bonferroni correction. The SSS, SRS, and SDS of OPCAB versus those of CCAB were 6.86 +/- 0.72 versus 7.17 +/- 0.92, 3.95 +/- 0.57 versus 3.75 +/- 0.73, and 2.91 +/- 0.47 versus 3.42 +/- 0.74 (P > .05). However, the lateral wall showed lower scores in OPCAB (ASS, 0.18 versus 0.41, P = .015; ARS, 0.12 versus 0.20, P = .168; ADS, 0.06 versus 0.21, P = .031). The septal wall had higher scores in OPCAB (ASS, 0.33 versus 0.12, P = .003; ARS, 0.18 versus 0.07, P = .037; ADS, 0.14 versus 0.04, P = .030). The anterior and inferior walls were not different between the 2 groups. OPCAB led to results similar to those of CCAB. The better results in the lateral wall have been the effect of grafting radial artery rather than vein. The similarity in myocardial reserve in the inferior wall between the 2 groups needs further study. There was no deleterious effect of off-pump as opposed to on-pump CAB.

  9. Effect of long-term cholesterol-lowering treatment with HMG-CoA reductase inhibitor (Simvastatin) of myocardial perfusion evaluated by thallium-201 single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Hosokawa, Ryohei; Nohara, Ryuji; Linxue, Li; Sasayama, Shigetake [Kyoto Univ. (Japan). Graduate School of Medicine; Tamaki, Shunichi; Hashimoto, Tetsuo; Tanaka, Masahiro; Miki, Shinji

    2000-03-01

    Fifteen patients with either angina pectoris or old myocardial infarction, who had positive {sup 201}Tl single photon emission computed tomography (SPECT) imaging and coronary sclerosis of more than 50%, were treated with an HMG-CoA reductase inhibitor (simvastatin) for more than 1 year. They were compared with an untreated control group (n=25). Total cholesterol decreased 22% and high-density lipoprotein (HDL) increased 9% with simvastatin; both changes were significantly different from those in controls. Long-term simvastatin induced improvement of myocardial perfusion on {sup 201}Tl SPECT images both during exercise and at rest, which was also significantly different from controls. In addition, the improvement of myocardial perfusion on {sup 201}Tl SPECT images was clearly related to the improvements in cholesterol values, especially nonHDL cholesterol. Thus, the greater the decrease in nonHDL cholesterol, the greater the improvement in myocardial perfusion at rest or during exercise with long-term treatment using an HMG-CoA reductase inhibitor. These findings indicate that the improvements in cholesterol values caused by HMG-CoA reductase inhibitor therapy are related to improvements of myocardial perfusion seen on {sup 201}Tl SPECT images. (author)

  10. Dual myocardial single photon emission computed tomography (SPECT) using thallium-201 and I-123-{beta}-methyl-i-pentadecanoic acid in patients with Duchenne's progressive muscular dystrophy

    Energy Technology Data Exchange (ETDEWEB)

    Shimoyama, Katsuya [Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine

    1999-10-01

    Dual single photon emission computed tomography (SPECT) was performed in 31 patients with Duchenne's progressive muscular dystrophy (DMD) using {sup 123}I-{beta}-methyl pentadecanoic acid (BMIPP) for myocardial fatty acid metabolism and {sup 201}thallium (Tl)-chloride for myocardial perfusion. The left ventricle was divided into 9 segments, and accumulation of the radiotracers was assessed visually for each segment to calculate defect score for each tracer. There was some degree of decrease in myocardial accumulation of both tracers in all DMD patients. Reduced accumulation was most common at the apex (BMIPP: 67%, Tl: 63%), followed by the posterior wall, lateral wall, and anterior wall. On the other hand, reduced accumulation was less common at the septum. BMIPP showed a higher accumulation than Tl in all segments but the septum. When BMIPP defect score was larger than Tl defect score, BMIPP defect score tended to increase during 4 years follow-up (p<0.042). However, when Tl defect score was larger than BMIPP defect score, an increase in Tl defect score was slight. A significant negative correlation was found between the sum of the BMIPP and Tl defect scores and the left ventricular ejection fraction (LVEF) (r=0.66, p<0.0001). According to the histo-pathological study of two autopsied hearts, severe myocardial fibrosis was seen in segments with fixed perfusion defect. In addition, the mismatched segments of BMIPP defect score > Tl defect score revealed a slight fibrosis or normal myocardium. It can be concluded that the dual SPECT myocardial scintigraphy using BMIPP and Tl provides accurate information about disease progression of the heart in patients with DMD by detecting abnormalities of the myocardial metabolism of each substance, thereby enabling the assessment of left ventricular function. (author)

  11. Repeat thallium-201 SPECT in cerebral lymphoma.

    Science.gov (United States)

    Borggreve, F; Dierckx, R A; Crols, R; Mathijs, R; Appel, B; Vandevivere, J; Mariën, P; Martin, J J; De Deyn, P P

    1993-01-01

    The authors report on the contribution of Thallium-201 brain SPECT in the diagnosis and follow-up of a non-immunosuppressed patient, presenting with primary cerebral lymphoma. The tumoral process was at first not diagnosed on CT-scan, but Thallium-201 SPECT suggested a tumoral invasion. During corticosteroid treatment the tumor volume on CT-scan decreased, while on Thallium-201 SPECT there was an enhancement of the accumulation and an increasing tumor to non-tumor ratio. These scintigraphical findings more closely reflected the clinical course and the postmortem results.

  12. Area at risk can be assessed by iodine-123-meta-iodobenzylguanidine single-photon emission computed tomography after myocardial infarction: a prospective study.

    Science.gov (United States)

    Hedon, Christophe; Huet, Fabien; Ben Bouallegue, Fayçal; Vernhet, Hélène; Macia, Jean-Christophe; Cung, Thien-Tri; Leclercq, Florence; Cade, Stéphane; Cransac, Frédéric; Lattuca, Benoit; Vandenberghe, D'Arcy; Bourdon, Aurélie; Benkiran, Meriem; Vauchot, Fabien; Gervasoni, Richard; D'estanque, Emmanuel; Mariano-Goulart, Denis; Roubille, François

    2018-02-01

    Myocardial salvage is an important surrogate endpoint to estimate the impact of treatments in patients with ST-segment elevation myocardial infarction (STEMI). The aim of this study was to evaluate the correlation between cardiac sympathetic denervation area assessed by single-photon emission computed tomography (SPECT) using iodine-123-meta-iodobenzylguanidine (I-MIBG) and myocardial area at risk (AAR) assessed by cardiac magnetic resonance (CMR) (gold standard). A total of 35 postprimary reperfusion STEMI patients were enrolled prospectively to undergo SPECT using I-MIBG (evaluates cardiac sympathetic denervation) and thallium-201 (evaluates myocardial necrosis), and to undergo CMR imaging using T2-weighted spin-echo turbo inversion recovery for AAR and postgadolinium T1-weighted phase sensitive inversion recovery for scar assessment. I-MIBG imaging showed a wider denervated area (51.1±16.0% of left ventricular area) in comparison with the necrosis area on thallium-201 imaging (16.1±14.4% of left ventricular area, Parea (P=0.23) and was adequately correlated (R=0.56, P=0.0002). Myocardial salvage evaluated by SPECT imaging (mismatch denervated but viable myocardium) was significantly higher than by CMR (P=0.02). In patients with STEMI, I-MIBG SPECT, assessing cardiac sympathetic denervation may precisely evaluate the AAR, providing an alternative to CMR for AAR assessment.

  13. Thallium-201 scintigraphy in unstable angina pectoris

    Energy Technology Data Exchange (ETDEWEB)

    Wackers, F.J.T.; Lie, K.I.; Liem, K.L.; Sokole, E.B.; Samson, G.; Van Der Schoot, J.B.; Durrer, D.

    1978-04-01

    Thallium-201 scintigraphy was performed during the pain free period in 98 patients with unstable angina. Scintiscans were positive in 39 patients, questionable in 27 patients and normal in 32 patients. Eighty-one patients responded favorably to treatment (group I). Seventeen patients had complicated courses (group II) and despite maximal treatment with propranolol either developed infarction (six patients) or continued to have angina necessitating coronary surgery (11 patients). In group I during the pain free period 26 of 81 patients had positive thallium-201 scans, whereas 20 patients had an abnormal ECG at that time; during angina 18 patients had transient ECG changes. In group II during the pain free period 13 of 17 patients had positive scans, whereas two patients had abnormal ECG at that time; during angina 12 patients showed transient ECG changes. The sensitivity to recognize group II was 76% for thallium-201 scintigraphy, 11% for ECG during the pain free period; 70% for ECG during angina; 94% for the combination of either positive scans or abnormal ECG. Thus, positive thallium-201 scans occur in patients with unstable angina, positive scans can be obtained during the pain free period, thallium-201 scans are more frequently positive in patients with complicated course.

  14. Brain mapping with single photon emission CT.

    Science.gov (United States)

    Matthew, E; Hill, T C

    1998-02-01

    To investigate the feasibility of performing brain mapping studies by using cortical activation paradigms and single photon emission computed tomography (SPECT) and to evaluate methods of analysis. Twenty healthy volunteers underwent technetium-99m bicisate SPECT under baseline conditions and during either full-field or right hemifield visual stimulation with a black and white reversing checkerboard pattern. Changes in regional cerebral perfusion were measured by using regions of interest (ROIs) and statistical parametric mapping. ROI analysis identified statistically significant increases in perfusion in the occipital cortex with full-field visual stimulation (mean +/- standard error of the mean percentage change from baseline: left, 8.0 +/- 1.5; right, 6.6 +/- 2.4). With right hemifield visual stimulation, perfusion was significantly increased only in the left occipital cortex (left, 5.2 +/- 1.5; right, -0.2 +/- 1.9). Statistical parametric mapping showed areas of activation (more than 100 voxel clusters showed significant change from baseline at a threshold value of P or = 2.58) in the left primary visual cortex (right hemifield visual stimulation) and in both right and left primary visual areas (full-field visual stimulation). Brain mapping studies were preformed with Tc-99m bicisate SPECT, and activation-induced changes were visualized and measured. These methods can be applied to develop improved methods of diagnosis and assessment of treatment outcome in patients with neuropsychiatric disorders.

  15. Dipyridamole-loading scintigraphy in patients with subendocardial infarction using single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Mori, Kiyoo; Masuda, Masanosuke (Hoju Memorial Hospital, Tatsunokuchi, Ishikawa (Japan)); Bunkou, Hisashi

    1988-12-01

    To detect myocardial lesions in patients with subendocardial (nontransmural) infarction, myocardial perfusion images of thallium-201 (Tl-201), using single photon emission computed tomography, were obtained in 17 patients during and three hours after coronary vasodilatation induced by the administration of dipyridamole. Controls consisted of 28 patients with transmural infarction and 11 with angina pectoris. Dipyridamole was infused intravenously at a rate of 0.142 mg/kg per min for four min, and the washout rate of Tl-201 was calculated by the segmental ROI method. Many patients with nontransmural infarction exhibited various Tl-201 myocardial perfusion images. The prevalence of redistribution among patients with nontransmural infarction was 88.2% (15 of 17), and its reverse redistribution was 64.7% (11 of 17). Every subject exhibited a number of abnormal Tl-201 myocardial perfusion images. In patients with nontransmural infarction the occurence of reverse redistribution images was significantly higher (64.7%) compared to those with transmural infarction (10.7%), and the occurrence of redistribution images was significantly higher (88.2%) compared to those with angina pectoris (45.5%). The abnormal perfusion images most frequently present in the areas corresponding to the sites of ST-T changes on ECG were reverse redistribution (26.7%), redistribution (17.3%), and fixed defect (6.7%) in order. The phenomenon of reverse redistribution images was found irrespective of stenotic coronary artery lesions on selective coronary angiography. Most areas corresponding to the sites of reverse redistribution showed ST-T changes on ECG and high washout rates of Tl-201. (J.P.N.).

  16. Evaluation of myocardial damage in Duchenne's muscular dystrophy with thallium-201 myocardial SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Tamura, Takuhisa; Shibuya, Noritoshi (Kawatana National Hospital, Nagasaki (Japan)); Hashiba, Kunitake; Oku, Yasuhiko; Mori, Hideki; Yano, Katsusuke

    1993-01-01

    Myocardial damage and cardiopulmonary functions in patients with Duchenne's muscular dystrophy (DMD) were assessed using thallium-201 myocardial single-photon emission computed tomography (SPECT) and technetium-99m multigated radionuclide angiography. Twenty-five patients with DMD were divided into 4 groups according to percent of perfusion defect (%PD) calculated by the bull's-eye method and age. PD was detected in 24 (96.0%) of 25 patients with DMD, and it spread from the left ventricular lateral wall to the anterior wall and/or interventricular septum. PD was detected even in a 6-year-old DMD boy. Patients in Group I (%PD[>=]10% and age<15 years old) were shown to have a higher risk of left-sided heart failure without respiratory failure. Patients in Group II (%PD[>=]10 and age[>=]15) showed decreased pulmonary function and worsened arterial blood gas values as compared with Group IV (%PD<10 and age[>=]15). There was no significant difference in cardiac function among the 4 groups. It is postulated that myocardial damage in Group II patients is dependent primarily on a deficiency of dystrophin and on chronic respiratory failure, and that some of them are at risk of cardiopulmonary failure. It is concluded that myocardial SPECT is useful for the early diagnosis of myocardial damage and evaluation of cardiopulmonary function in DMD patients. (author).

  17. Reduced left ventricular cavitary activity ("black hole sign") in thallium-201 SPECT perfusion images of anteroapical transmural myocardial infarction.

    Science.gov (United States)

    Civelek, A C; Shafique, I; Brinker, J A; Durski, K; Weiss, J L; Links, J M; Natarajan, T K; Ozguven, M A; Wagner, H N

    1991-11-01

    Apparently reduced left ventricular (LV) cavitary thallium activity in both planar and tomographic perfusion images has been previously observed by these and other investigators. With single-photon emission computerized tomography, we have clinically noted that this "black hole sign" was associated with an aneurysm in the setting of a transmural anterior or anteroapical perfusion defect. We have now prospectively studied the etiology and predictive value of this sign in 84 consecutive patients with an anterior, anteroapical transmural perfusion defect. Of the 84 patients, 49 had both LV aneurysm (confirmed by contrast ventriculography, echocardiography or gated blood pool studies) and a black hole sign. Only 1 patient with an aneurysm did not have the black hole sign, and 2 without aneurysm did. Thus, it is concluded that this sign is highly accurate in diagnosing LV aneurysm. Because thallium-201 single-photon emission computerized tomography imaging is often performed as one of the first diagnostic tests soon after myocardial infarction, this has important clinical management implications.

  18. Combined thallium-201 and dynamic iodine-123 iodophenylpentadecanoic acid single-photon emission computed tomography in patients after acute myocardial infarction with effective reperfusion.

    Science.gov (United States)

    Richter, W S; Beckmann, S; Cordes, M; Schuppenhauer, T; Schartl, M; Munz, D L

    2000-12-01

    Considerable derangements of energy metabolism are to be expected during ischemia and reperfusion. In ischemic myocardium, the oxidative degradation of carbohydrates is shifted toward the anaerobic production of lactate and the oxidation of fatty acids is suppressed. The aim of this study was to examine the uptake and metabolism of iodine-123 (123I) iodophenylpentadecanoic acid (IPPA) in stunned myocardium. In 15 patients, SPECT with 201Tl and 123I IPPA as well as echocardiography with low-dose dobutamine stimulation were performed 12 +/- 5 days after myocardial infarction with reperfusion. Follow-up echocardiography was carried out 24 +/- 8 days later for documentation of functional improvement. Uptake of 201Tl and 123I IPPA were obtained in five left ventricular segments, and dynamic SPECT imaging was used for calculation of the fast and the slow components of the biexponential myocardial 123I IPPA clearance. Wall motion improved in 14 of 26 dysfunctional segments (54%). Stunned segments were characterized by a reduced 123I IPPA extraction, a shorter half-life of the fast, and a longer half-life of the slow clearance component. All parameters of the combined 201Tl/123I IPPA study predicted functional recovery with similar accuracies (area under the receiver operator characteristic curves between 0.68 and 0.76; p = NS). Analysis of 201Tl uptake alone could not predict functional recovery in this study. Stunned myocardium is characterized by a disturbance of fatty acid metabolism. For prediction of functional improvement, 123I IPPA imaging added significant diagnostic information.

  19. Left ventricular dilatation and pulmonary thallium uptake after single-photon emission computer tomography using thallium-201 during adenosine-induced coronary hyperemia

    Energy Technology Data Exchange (ETDEWEB)

    Iskandrian, A.S.; Heo, J.; Nguyen, T.; Lyons, E.; Paugh, E. (Philadelphia Heart Institute, PA (USA))

    1990-10-01

    This study examined the implications of left ventricular (LV) dilatation and increased pulmonary thallium uptake during adenosine-induced coronary hyperemia. The lung-to-heart thallium ratio in the initial images was significantly higher in patients with coronary artery disease (CAD) than normal subjects; 0.48 +/- 0.16 in 3-vessel disease (n = 16), 0.43 +/- 0.10 in 2-vessel disease (n = 20), 0.43 +/- 0.08 in 1-vessel disease (n = 16) and 0.36 +/- 0.05 in normal subjects (n = 7) (p less than 0.001, 0.09 and 0.06, respectively). There was a significant correlation between the severity and the extent of the perfusion abnormality (determined from the polar maps) and the lung-to-heart thallium ratio (r = 0.51 and 0.52, respectively, p less than 0.0002). There was also a significant correlation between lung thallium washout and lung-to-heart thallium ratio (r = 0.42, p = 0.0009) and peak heart rate (r = -0.49, p less than 0.0001). The LV dilatation was mostly due to an increase in cavity dimension (30% increase) and to a lesser extent (6% increase) due to increase in LV size. (The cavity dimensions were measured from the short-axis slices at the midventricular level in the initial and delayed images). The dilation was seen in patients with CAD but not in the normal subjects. These changes correlated with the extent and severity of the thallium perfusion abnormality. Thus, adenosine-induced coronary hyperemia may cause LV dilation and increased lung thallium uptake on the basis of subendocardial ischemia.

  20. A new method of detecting subendocardial ischemia in patients with aortic valvular stenosis without coronary artery disease using thallium-201 single photon emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Umamoto, Ikuo; Sugihara, Hiroki; Harada, Yoshiaki (Kyoto Prefectural Univ. of Medicine (Japan)) (and others)

    1993-02-01

    The purpose of this study was to detect myocardial ischemia in aortic valvular stenosis (AVS) without coronary artery disease by using exercise Tl-201 SPECT. The subjects were 18 AVS patients. Twenty other patients were served as controls. Transient 'left ventricular subendocardial dilation and decreased wall thickness', obtained on early SPECT images, were quantitatively determined by transient dilation index (TDI). Washout rates (WR) were calculated from overlapping early and delayed images to obtain WR map. According to TDI, 18 AVS patients were classified as having TDI[<=]1.11 (Group A, n=9) and TDI>1.11 (Group B, n=9). WR map in Group B presented the direction from the pericardial toward the endocardial side, revealing a pattern of decreased WR and a decreased coronary flow reserve on the endocardial side. Both pressure gradient between the aorta and left ventricle and left ventricular wall thickness were significantly greater in Group B than Group A. In 3 patients in Group B, TDI returned to normal and WR map became homogeneous after aortic valve replacement. In addition, fibrosis was noted in the endocardial site on biopsy. In AVS associated with great pressure gradient, endocardial ischemia may occur on exercise, resulting from a decreased coronary flow reserve, and a decreased compliance due to fibrosis and hypertrophy. Exercise Tl-201 myocardial SPECT is capable of detecting distribution patterns of subendocardial ischemia and coronary flow reserve in AVS. (N.K.).

  1. MRI and thallium-201 SPECT in the prediction of survival in glioma

    Energy Technology Data Exchange (ETDEWEB)

    Vos, Maaike J. [VU University Medical Center, Department of Neurology, Amsterdam (Netherlands); Medical Center Haaglanden, Department of Neurology, PO Box 432, The Hague (Netherlands); Berkhof, Johannes [VU University Medical Center, Department of Epidemiology and Biostatistics, Amsterdam (Netherlands); Hoekstra, Otto S. [VU University Medical Center, Department of Nuclear Medicine and PET Research, Amsterdam (Netherlands); Bosma, Ingeborg; Sizoo, Eefje M.; Heimans, Jan J.; Reijneveld, Jaap C.; Postma, Tjeerd J. [VU University Medical Center, Department of Neurology, Amsterdam (Netherlands); Sanchez, Esther [VU University Medical Center, Department of Radiology, Amsterdam (Netherlands); Lagerwaard, Frank J. [VU University Medical Center, Department of Radiation Oncology, Amsterdam (Netherlands); Buter, Jan [VU University Medical Center, Department of Medical Oncology, Amsterdam (Netherlands); Noske, David P. [VU University Medical Center, Department of Neurosurgery and Neuro-Oncology Research Group, Amsterdam (Netherlands)

    2012-06-15

    This paper aims to study the value of MRI and Thallium 201 ({sup 201}Tl) single-photon emission computed tomography (SPECT) in the prediction of overall survival (OS) in glioma patients treated with temozolomide (TMZ) and to evaluate timing of radiological follow-up. We included patients treated with TMZ chemoradiotherapy for newly diagnosed glioblastoma multiforme (GBM) and with TMZ for recurrent glioma. MRIs and {sup 201}Tl SPECTs were obtained at regular intervals. The value of both imaging modalities in predicting OS was examined using Cox regression analyses. Altogether, 138 MRIs and 113 {sup 201}Tl SPECTs in 46 patients were performed. Both imaging modalities were strongly related to OS (P {<=} 0.02). In newly diagnosed GBM patients, the last follow-up MRI (i.e., after six adjuvant TMZ courses) and SPECT (i.e., after three adjuvant TMZ courses) were the strongest predictors of OS (P = 0.01). In recurrent glioma patients, baseline measurements appeared to be the most predictive of OS (P < 0.01). The addition of one imaging modality to the other did not contribute to the prediction of OS. Both MRI and {sup 201}Tl SPECT are valuable in the prediction of OS. It is adequate to restrict to one of both modalities in the radiological follow-up during treatment. In the primary GBM setting, MRI after six adjuvant TMZ courses contributes significantly to the prediction of survival. In the recurrent glioma setting, baseline MRI appears to be a powerful predictor of survival, whereas follow-up MRIs during TMZ seem to be of little additional value. (orig.)

  2. Quantitative evaluation of thallium-201 myocardial scintigram in coronary artery diseases

    Energy Technology Data Exchange (ETDEWEB)

    Mikada, Ken-etsu (Akita Univ. (Japan). School of Medicine)

    1992-11-01

    Quantitative indices from circumferential profile curves of thallium-201 ([sup 201]Tl) myocardial scintigram were evaluated for diagnostic utility in coronary artery diseases (CAD). Myocardial [sup 201]Tl scintigrams with single photon emission computed tomography (SPECT) were obtained 5 minutes (early) and 4 hours (delayed) after exercise in 20 normal subjects and 66 cases of CAD, of which 20 were angina pectoris without myocardial infarction (AP), 14 were subendocardial infarction (non-QMI) and 32 were Q-wave infarction (QMI). Tl counts, %Tl uptake and washout ratio (WR) were measured in 81 segments (9 apical segments of the slice from the longitudinal axis and all 72 segments of two slices from the short axis). A mean early defect (MED), a mean delayed defect (MDD), a mean delta washout rate (MDR), and a [Sigma] delayed defect ([Sigma]DD) were calculated from the areas which were below the two standard deviations of the mean %Tl uptake in normal subjects. A mean filling-in (MFI) was calculated from the difference of the %Tl uptake between early and delayed curves in each patient. In patients with CAD, the MED and MFI were higher, but MDW was lower with a more severe coronary stenosis, indicating that these indices were useful to detect myocardial hypo-perfuion. In severely stenotic regions, the MDD was higher in QMI than in AP and non-QMI, indicating that the ratio of infarct to the myocardium in the region was higher in QMI. In QMI, [Sigma]DD correlated well (r=0.723) with Total Wall Motion Scores with two-dimentional echocardiography which was directly related with infarct size. Further, MED, MFI and MDW were improved after aortocoronary bypass only in patients with patent graft. It is concluded that this quantitative evaluation with [sup 201]Tl-SPECT can provide an objective and quantitative estimate of regional myocardial ischemia and infarct. (author).

  3. Usefulness of thallium-201 SPECT in the evaluation of tumor natures in intracranial meningiomas

    Energy Technology Data Exchange (ETDEWEB)

    Takeda, Tetsuji; Nakano, Takahiro; Asano, Kenichiroh; Shimamura, Norihito; Ohkuma, Hiroki [Hirosaki University Graduate School of Medicine, Department of Neurosurgery, Hirosaki (Japan)

    2011-11-15

    Although intracranial meningiomas are regarded as benign tumors, some of them behave clinically as malignant tumors. Past reports suggest that MIB 1 and vascular endothelial growth factor (VEGF) in postoperative tumor specimens correlate with the aggressive nature of tumors, but preoperative prediction of such a nature is more useful for therapeutic planning for the tumor. The purpose of this study was to assess the usefulness of preoperative thallium-201 chloride single-photon emission computed tomography (Tl SPECT) to evaluate biological behavior in intracranial meningiomas. Tl SPECT was performed on 39 patients with intracranial meningioma and Tl uptake indices were calculated. The difference in the Tl uptake index between atypical meningiomas and other pathological types of meningioma was evaluated. Moreover, correlation of Tl uptake indices with the MIB1 labeling index was estimated. Tl uptake indices were also compared between VEGF strongly positive and weakly positive meningiomas. The delayed index of atypical meningioma was significantly higher than that of the other pathological types (p = 0.036). Significant correlation was found between the Tl uptake index in the delayed image and MIB1 labeling index (p < 0.0001, R{sup 2} = 0.36). Moreover, VEGF strongly positive meningiomas exhibited a significantly higher Tl uptake index compared to VEGF weakly positive meningiomas in both the early image and the delayed image (p = 0.029, 0.023, respectively). Tl uptake index may be a possible preoperative surrogate marker of MIB1 and VEGF that is useful in detecting aggressive natures in intracranial meningiomas. (orig.)

  4. Directional emission of single photons from small atomic samples

    DEFF Research Database (Denmark)

    Miroshnychenko, Yevhen; V. Poulsen, Uffe; Mølmer, Klaus

    2013-01-01

    We provide a formalism to describe deterministic emission of single photons with tailored spatial and temporal profiles from a regular array of multi-level atoms. We assume that a single collective excitation is initially shared by all the atoms in a metastable atomic state, and that this state i...... is coupled by a classical laser field to an optically excited state which rapidly decays to the ground atomic state. Our model accounts for the different field polarization components via re-absorption and emission of light by the Zeeman manifold of optically excited states....

  5. Thallium-201 is comparable to technetium-99m-sestamibi for estimating cardiac function in patients with abnormal myocardial perfusion imaging

    Directory of Open Access Journals (Sweden)

    Ming-Che Wu

    2015-11-01

    Full Text Available We analyzed the left-ventricular functional data obtained by cardiac-gated single-photon emission computed tomography myocardial perfusion imaging (MPI with thallium-201 (Tl-201 and technetium-99m-sestamibi (MIBI protocols in different groups of patients, and compared the data between Tl-201 and MIBI. Two hundred and seventy-two patients undergoing dipyridamole stress/redistribution Tl-201 MPI and 563 patients undergoing 1-day rest/dipyridamole stress MIBI MPI were included. Higher mean stress ejection fraction (EF, rest EF, and change in EF (ΔEF were noticed in the normal MPI groups by both Tl-201 and MIBI protocols. Higher mean EF was observed in the females with normal MPI results despite their higher mean age. Comparisons between the Tl-201 and MIBI groups suggested a significant difference in all functional parameters, except for the rest end diastolic volume/end systolic volume and ΔEF between groups with negative MPI results. For the positive MPI groups, there was no significant difference in all parameters, except for the change in end diastolic volume and change in end systolic volume after stress between both protocols. The Tl-201 provides comparable left-ventricular functional data to MIBI cardiac-gated single-photon emission computed tomography in patients with positive MPI results, and may therefore be undertaken routinely for incremental functional information that is especially valuable to this patient group.

  6. A comparison of the clinical relevance of thallium201 and ...

    African Journals Online (AJOL)

    Thallium-201 is at present the radiotracer of choice for the clinical evaluation of myocardial blood flow. Although different technetium-99m-isonitrile agents have been synthesised recently, only 99mTc-melhoxyisobutyl-isonitrile (99mTc_MIBI) has proved to hold promise for clinical implementation. The myocardial distribution ...

  7. Assessment of the effect of revascularization early after CABG using ECG-gated perfusion single-photon emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kubo, Shigeto; Tadamura, Eiji; Kudoh, Takashi; Inubushi, Masayuki; Konishi, Junji [Dept. of Nuclear Medicine and Diagnostic Imaging, Kyoto University Graduate (Japan); Ikeda, Tadashi; Koshiji, Takaaki; Nishimura, Kazunobu; Komeda, Masashi [Dept. of Cardiovascular Surgery, Kyoto University (Japan); Tamaki, Nagara [Dept. of Nuclear Medicine, Hokkaido University, Sapporo (Japan)

    2001-02-01

    When an arterial graft is used, reversible perfusion defects on single-photon emission tomography (SPET) perfusion images are occasionally observed early after coronary artery bypass graft surgery (CABG), owing to the restricted flow capacity. The purpose of this study was to determine whether the functional information obtained with electrocardiography (ECG)-gated perfusion SPET could be helpful in evaluating the effect of revascularization early after CABG. Twenty-three patients (18 men and 5 women, mean age 65{+-}9 years) underwent stress/re-injection thallium-201 ECG-gated SPET before and 4 weeks after CABG (13 with exercise and 10 with dipyridamole). Patency of all grafts was confirmed by coronary angiography 1 month after CABG. Cardiac functional data including the left ventricular ejection fraction (LVEF) and the transient ischaemic dilatation (TID) ratio were analysed using a commercially available automated program. The conventional stress and re-injection tomograms were interpreted by means of a five-point scoring system in a nine-segment model. Stress-induced reversible {sup 201}Tl perfusion defects were present in 64% of the myocardial segments bypassed by patent arterial grafts, in contrast to 42% of the myocardial segments bypassed by patent venous grafts ({chi}{sup 2}=7.8, P=0.005). Of the 23 patients, 12 showed improvement in summed ischaemic scores (group 1), while 11 had no change or deterioration (group 2), although all grafts were patent on postoperative catheterization. The TID ratio improved in both group 1 and group 2 before and after CABG (1.14{+-}0.13 vs 0.99{+-}0.07, P=0.001 and 1.09{+-}0.07 vs 0.94{+-}0.05, P=0.002, respectively). However, LVEF did not significantly improve in group 1 or group 2 after CABG (42.5%{+-}9.9% vs 47.5%{+-}11.8%, and 52.1%{+-}7.5% vs 53.1%{+-}5.9%, respectively). Perfusion imaging or LVEF assessment is of limited value early after CABG. The TID ratio obtained with ECG-gated perfusion SPET may be a useful marker

  8. Single Photon Emission Tomography Imaging in Parkinsonian Disorders: A Review

    Directory of Open Access Journals (Sweden)

    Paul D. Acton

    2000-01-01

    Full Text Available Parkinsonian symptoms are associated with a number of neurodegenerative disorders, such as Parkinson’s disease, multiple system atrophy and progressive supranuclear palsy. Pathological evidence has shown clearly that these disorders are associated with a loss of neurons, particularly in the nigrostriatal dopaminergic pathway. Positron emission tomography (PET and single photon emission tomography (SPECT now are able to visualise and quantify changes in cerebral blood flow, glucose metabolism, and dopaminergic function produced by parkinsonian disorders. Both PET and SPECT have become important tools in the differential diagnosis of these diseases, and may have sufficient sensitivity to detect neuronal changes before the onset of clinical symptoms. Imaging is now being utilised to elucidate the genetic contribution to Parkinson’s disease, and in longitudinal studies to assess the efficacy and mode of action of neuroprotective drug and surgical treatments. This review summarises recent applications of SPECT imaging in the study of parkinsonian disorders, with particular reference to the increasing role it is playing in the understanding, diagnosis and management of these diseases.

  9. Brain single photon emission computed tomography in neonates

    Energy Technology Data Exchange (ETDEWEB)

    Denays, R.; Van Pachterbeke, T.; Tondeur, M.; Spehl, M.; Toppet, V.; Ham, H.; Piepsz, A.; Rubinstein, M.; Nol, P.H.; Haumont, D. (Free Universities of Brussels (Belgium))

    1989-08-01

    This study was designed to rate the clinical value of ({sup 123}I)iodoamphetamine (IMP) or ({sup 99m}Tc) hexamethyl propylene amine oxyme (HM-PAO) brain single photon emission computed tomography (SPECT) in neonates, especially in those likely to develop cerebral palsy. The results showed that SPECT abnormalities were congruent in most cases with structural lesions demonstrated by ultrasonography. However, mild bilateral ventricular dilatation and bilateral subependymal porencephalic cysts diagnosed by ultrasound were not associated with an abnormal SPECT finding. In contrast, some cortical periventricular and sylvian lesions and all the parasagittal lesions well visualized in SPECT studies were not diagnosed by ultrasound scans. In neonates with subependymal and/or intraventricular hemorrhage the existence of a parenchymal abnormality was only diagnosed by SPECT. These results indicate that ({sup 123}I)IMP or ({sup 99m}Tc)HM-PAO brain SPECT shows a potential clinical value as the neurodevelopmental outcome is clearly related to the site, the extent, and the number of cerebral lesions. Long-term clinical follow-up is, however, mandatory in order to define which SPECT abnormality is associated with neurologic deficit.

  10. Electrically driven single-photon emission from an isolated single molecule.

    Science.gov (United States)

    Zhang, Li; Yu, Yun-Jie; Chen, Liu-Guo; Luo, Yang; Yang, Ben; Kong, Fan-Fang; Chen, Gong; Zhang, Yang; Zhang, Qiang; Luo, Yi; Yang, Jin-Long; Dong, Zhen-Chao; Hou, J G

    2017-09-18

    Electrically driven molecular light emitters are considered to be one of the promising candidates as single-photon sources. However, it is yet to be demonstrated that electrically driven single-photon emission can indeed be generated from an isolated single molecule notwithstanding fluorescence quenching and technical challenges. Here, we report such electrically driven single-photon emission from a well-defined single molecule located inside a precisely controlled nanocavity in a scanning tunneling microscope. The effective quenching suppression and nanocavity plasmonic enhancement allow us to achieve intense and stable single-molecule electroluminescence. Second-order photon correlation measurements reveal an evident photon antibunching dip with the single-photon purity down to g (2) (0) = 0.09, unambiguously confirming the single-photon emission nature of the single-molecule electroluminescence. Furthermore, we demonstrate an ultrahigh-density array of identical single-photon emitters.Molecular emitters offer a promising solution for single-photon generation. Here, by exploiting electronic decoupling by an ultrathin dielectric spacer and emission enhancement by a resonant plasmonic nanocavity, the authors demonstrate electrically driven single-photon emission from a single molecule.

  11. Myocardial perfusion single photon emission computed tomography in asymptomatic diabetics.

    Science.gov (United States)

    Harshad, K; Sathyamurthy, I; Ashish, G; Padma, D; Shelley, S; Indirani, M; Subramanian, K

    2010-01-01

    Coronary artery disease (CAD) is the most important cause of mortality in diabetic patients. Diabetes mellitus (DM) due to autonomic neuropathy leads to asymptomatic CAD. Hence, it is important to screen the patients with DM for CAD. To study the prevalence of asymptomatic CAD by Myocardial Perfuision SPECT (Single Photon Emission Computed Tomography) (MPS) in diabetics. This prospective study included 88 asymptomatic patients (58 males and 30 females) of Type 2 DM of more than 5 years duration in the age group of 40-65 years. Risk factors like hypertension, dyslipidemia, smoking, family history of CAD and Body Mass Index > or = 25 kg/sq.m were assessed. All these patients underwent MPS study as two day standard protocol. Thirty eight patients underwent invasive Coronary Angiography (CAG) and stenosis greater than 50% was considered significant. Abnormal perfusion was detected in 38 (43%) diabetics and 4 (11%) controls. A total of 81 perfusion defects were identified (19 fired and 62 reversible). CAG showed significant coronary stenosis in 26 (68.4%), insignificant in 8 (21%) and no stenosis in 4 (10.6%) patients. A total of 114 coronaries were analysed, significant stenosis in 67 (58.8%) coronaries, 21 (18.4%) had insignificant lesions and 26(22.8%) were normal. In comparison to CAG, MPS had sensitivity of 86.6% and specificity of 51%. The Myocardial Perfusion SPECT is a sensitive diagnostic tool to identify ischemia in asymptomatic diabetics. MPS can be used as screening test for risk stratification. It has a prognostic value in predicting the outcome of CAD and can be useful for long-term follow up too.

  12. Proceedings of clinical SPECT (single photon emission computed tomography) symposium

    Energy Technology Data Exchange (ETDEWEB)

    1986-09-01

    It has been five years since the last in-depth American College of Nuclear Physicians/Society of Nuclear Medicine Symposium on the subject of single photon emission computed tomography (SPECT) was held. Because this subject was nominated as the single most desired topic we have selected SPECT imaging as the basis for this year's program. The objectives of this symposium are to survey the progress of SPECT clinical applications that have taken place over the last five years and to provide practical and timely guidelines to users of SPECT so that this exciting imaging modality can be fully integrated into the evaluation of pathologic processes. The first half was devoted to a consideration of technical factors important in SPECT acquisition and the second half was devoted to those organ systems about which sufficient clinical SPECT imaging data are available. With respect to the technical aspect of the program we have selected the key areas which demand awareness and attention in order to make SPECT operational in clinical practice. These include selection of equipment, details of uniformity correction, utilization of phantoms for equipment acceptance and quality assurance, the major aspect of algorithms, an understanding of filtered back projection and appropriate choice of filters and an awareness of the most commonly generated artifacts and how to recognize them. With respect to the acquisition and interpretation of organ images, the faculty will present information on the major aspects of hepatic, brain, cardiac, skeletal, and immunologic imaging techniques. Individual papers are processed separately for the data base. (TEM)

  13. Adenosine myocardial perfusion single-photon emission computed tomography in women compared with men. Impact of diabetes mellitus on incremental prognostic value and effect on patient management.

    Science.gov (United States)

    Berman, Daniel S; Kang, Xingping; Hayes, Sean W; Friedman, John D; Cohen, Ishac; Abidov, Aiden; Shaw, Leslee J; Amanullah, Aman M; Germano, Guido; Hachamovitch, Rory

    2003-04-02

    This study was designed to assess the incremental prognostic value of adenosine stress myocardial perfusion single-photon emission computed tomography (MPS) in women versus men, and to explore the prognostic impact of diabetes mellitus. Limited data are available regarding the incremental value of adenosine stress MPS for the prediction of cardiac death in women versus men and the impact of diabetes mellitus on post-adenosine MPS outcomes. Of 6,173 consecutive patients who underwent rest thallium-201/adenosine technetium-99m sestamibi MPS, 254 (4.1%) were lost to follow-up, and 586 with early revascularization women and 2,677 men. Women had significantly smaller adenosine stress, rest, and reversible defects than men. During 27.0 +/- 8.8 month follow-up, cardiac death rates were lower in women than men (2.0%/year vs. 2.7%/year, respectively, p men and women as a function of MPS results. Multivariable models revealed that MPS results provided incremental prognostic value over pre-scan data for the prediction of cardiac death in both genders. Also, while comparative unadjusted rates of early (women (p men and women. Importantly, diabetic women had a significantly greater risk of cardiac death compared with other patients. Also, after risk adjustment, patients with insulin-dependent diabetes mellitus (IDDM) had higher risk of cardiac death for any MPS result than patients with non-insulin-dependent diabetes mellitus. The findings suggest that adenosine MPS has comparable incremental value for prediction of cardiac death in women and men and that MPS is appropriately influencing subsequent invasive management decisions in both genders. Diabetic women and patients with IDDM appear to have greater risk of cardiac death than other patients for any MPS result.

  14. A comparison of the clinical relevance of thallium- 201 and ...

    African Journals Online (AJOL)

    1990-09-01

    Sep 1, 1990 ... group of 20 patients, who underwent both 201TI single photon emission computed tomography and 99mTc_MIBI study as well as coronary angiography. The sensitivity for predicting a lesion ranged from 25% to 88% in different areas of the heart and was comparable for the two radiophannaceuticals. The.

  15. Central benzodiazepine receptor imaging and quantitation with single photon emission computerised tomography

    DEFF Research Database (Denmark)

    Okocha, C I; Kapczinski, F; Lassen, N

    1995-01-01

    This review discusses the current use of single photon emission computerised tomography (SPECT) for central benzodiazepine receptor imaging and quantitation. The general principles underlying SPECT imaging and receptor quantitation methods such as the kinetic, pseudo-equilibrium and steady...

  16. Temperature dependence of the single photon emission from interface-fluctuation GaN quantum dots.

    Science.gov (United States)

    Le Roux, F; Gao, K; Holmes, M; Kako, S; Arita, M; Arakawa, Y

    2017-11-23

    The temperature dependent single photon emission statistics of interface-fluctuation GaN quantum dots are reported. Quantum light emission is confirmed at temperatures up to ~77 K, by which point the background emission degrades the emission purity and results in a measured g(2) (0) in excess of 0.5. A discussion on the extent of the background contamination is also given through comparison to extensive data taken under various ambient and experimental conditions, revealing that the quantum dots themselves are emitting single photons with high purity.

  17. Single photon emission from site-controlled InGaN/GaN quantum dots

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Lei; Hill, Tyler A.; Deng, Hui, E-mail: dengh@umich.edu [Department of Physics, University of Michigan, 450 Church Street, Ann Arbor, Michigan 48109 (United States); Teng, Chu-Hsiang; Lee, Leung-Kway; Ku, Pei-Cheng, E-mail: peicheng@umich.edu [Department of Electrical Engineering and Computer Science, University of Michigan, 1301 Beal Ave., Ann Arbor, Michigan 48109 (United States)

    2013-11-04

    Single photon emission was observed from site-controlled InGaN/GaN quantum dots. The single-photon nature of the emission was verified by the second-order correlation function up to 90 K, the highest temperature to date for site-controlled quantum dots. Micro-photoluminescence study on individual quantum dots showed linearly polarized single exciton emission with a lifetime of a few nanoseconds. The dimensions of these quantum dots were well controlled to the precision of state-of-the-art fabrication technologies, as reflected in the uniformity of their optical properties. The yield of optically active quantum dots was greater than 90%, among which 13%–25% exhibited single photon emission at 10 K.

  18. Single photon emission computed tomography and serial MRI in preterm infants with kernicterus.

    Science.gov (United States)

    Okumura, Akihisa; Hayakawa, Fumio; Maruyama, Koichi; Kubota, Tetsuo; Kato, Katsuhiko; Watanabe, Kazuyoshi

    2006-07-01

    Single photon emission computed tomography was performed in three preterm infants with athetoid cerebral palsy due to kernicterus. No clinical signs and symptoms of kernicterus, or ultrasonographic abnormalities were seen during the neonatal period in any patients. Although MRI during infancy revealed high intensity areas in bilateral globi pallidi in all of them, MRI abnormalities were mild in two of them. On later MRI, subtle high intensity areas in the globi pallidi were recognized in only one of them. Single photon emission computed tomography demonstrated hypoperfusion in the basal ganglia regions in all patients. Regions of interest analyses showed decreased blood flow in the basal ganglia related to the cortical areas. Single photon emission computed tomography will be useful for the diagnosis of kernicterus, whereas MRI abnormalities become less clear beyond infancy.

  19. Controlling light emission from single-photon sources using photonic nanowires

    DEFF Research Database (Denmark)

    Gregersen, Niels; Chen, Yuntian; Mørk, Jesper

    2012-01-01

    are used to tailor the far-field emission pattern. This non-resonant approach relaxes the demands to fabrication perfection, allowing for record-high measured efficiency of fabricated nanowire single-photon sources. We review recent progress in photonic nanowire technology and present next generation...

  20. Technetium-99m pyrophosphate/thallium-201 dual-isotope SPECT imaging predicts reperfusion injury in patients with acute myocardial infarction after reperfusion

    Energy Technology Data Exchange (ETDEWEB)

    Akutsu, Yasushi; Kaneko, Kyouichi; Kodama, Yusuke; Li, Hui-Ling; Nishimura, Hideki; Hamazaki, Yuji; Kobayashi, Youichi [Showa University School of Medicine, Division of Cardiology, Department of Medicine, Tokyo (Japan); Suyama, Jumpei; Shinozuka, Akira; Gokan, Takehiko [Showa University School of Medicine, Department of Radiology, Tokyo (Japan)

    2009-02-15

    Microcirculatory failure after reperfusion is clinically indicated to cause reperfusion injury whereas excessive intracellular calcium ion overload is experimentally proved as a key mechanism of reperfusion injury. We hypothesized that technetium-99m ({sup 99m}Tc) pyrophosphate (Tc-PYP) uptake in injured but viable infarct-related myocardium with preserved myocardial perfusion after reperfusion estimated by thallium-201 ({sup 201}Tl) uptake would be associated with final functional recovery. Dual-isotope Tc-PYP/{sup 201}Tl single-photon emission computed tomography (SPECT) was performed 2 days after successful reperfusion therapy in patients with first acute myocardial infarction, and 50 patients (63 {+-} 13 years old, female 22%) with preserved {sup 201}Tl uptakes of {>=}50% in reperfused myocardium was followed for 1 month. Tc-PYP uptake was assessed as the heart-to-sternum (H/S) ratio. Two-dimensional echocardiography was also performed 2 days and 1 month after reperfusion to evaluate functional recovery. High Tc-PYP uptake, defined as the H/S ratio {>=}0.81, was predictive of chronic phase no functional recovery (73.7% in 14 of 19 patients with high uptake vs 16.1% in five of 31 patients without those, p < 0.0001). After adjustment for potential confounding variables, including electrocardiographic persistent ST segment elevation at 1 h after reperfusion, high Tc-PYP uptake remained independently predictive of no functional recovery with odds ratio of 8.7 (95% confidential interval = 2 to 38.7; p = 0.005). High Tc-PYP uptake in reperfused but viable infarct-related myocardium was a powerful predictor of no functional recovery, which may reflect excessive intracellular calcium ion overload caused by reperfusion injury. Tc-PYP/{sup 201}Tl dual-isotope SPECT imaging can provide prognostic information after reperfusion. (orig.)

  1. Super-resolution from single photon emission: toward biological application

    Science.gov (United States)

    Moreva, E.; Traina, P.; Forneris, J.; Ditalia Tchernij, S.; Guarina, L.; Franchino, C.; Picollo, F.; Ruo Berchera, I.; Brida, G.; Degiovanni, I. P.; Carabelli, V.; Olivero, P.; Genovese, M.

    2017-08-01

    Properties of quantum light represent a tool for overcoming limits of classical optics. Several experiments have demonstrated this advantage ranging from quantum enhanced imaging to quantum illumination. In this work, experimental demonstration of quantum-enhanced resolution in confocal fluorescence microscopy will be presented. This is achieved by exploiting the non-classical photon statistics of fluorescence emission of single nitrogen-vacancy (NV) color centers in diamond. By developing a general model of super-resolution based on the direct sampling of the kth-order autocorrelation function of the photoluminescence signal, we show the possibility to resolve, in principle, arbitrarily close emitting centers. Finally, possible applications of NV-based fluorescent nanodiamonds in biosensing and future developments will be presented.

  2. Dynamics of Single-Photon Emission from Electrically Pumped Color Centers

    Science.gov (United States)

    Khramtsov, Igor A.; Agio, Mario; Fedyanin, Dmitry Yu.

    2017-08-01

    Low-power, high-speed, and bright electrically driven true single-photon sources, which are able to operate at room temperature, are vital for the practical realization of quantum-communication networks and optical quantum computations. Color centers in semiconductors are currently the best candidates; however, in spite of their intensive study in the past decade, the behavior of color centers in electrically controlled systems is poorly understood. Here we present a physical model and establish a theoretical approach to address single-photon emission dynamics of electrically pumped color centers, which interprets experimental results. We support our analysis with self-consistent numerical simulations of a single-photon emitting diode based on a single nitrogen-vacancy center in diamond and predict the second-order autocorrelation function and other emission characteristics. Our theoretical findings demonstrate remarkable agreement with the experimental results and pave the way to the understanding of single-electron and single-photon processes in semiconductors.

  3. Single photon emission computed tomography for the diagnosis of coronary artery disease: an evidence-based analysis.

    Science.gov (United States)

    2010-01-01

    THE DIAGNOSIS OF CORONARY ARTERY DISEASE: An Evidence-Based AnalysisPease note that two related evidence-based analyses of non-invasive cardiac imaging technologies for the assessment of myocardial viability are also available on the MAS website:POSITRON EMISSION TOMOGRAPHY FOR THE ASSESSMENT OF MYOCARDIAL VIABILITY: An Evidence-Based AnalysisMAGNETIC RESONANCE IMAGING FOR THE ASSESSMENT OF MYOCARDIAL VIABILITY: an Evidence-Based AnalysisThe Toronto Health Economics and Technology Assessment Collaborative has also produced an associated economic report entitled:The Relative Cost-effectiveness of Five Non-invasive Cardiac Imaging Technologies for Diagnosing Coronary Artery Disease in Ontario [Internet]. Available from: http://theta.utoronto.ca/reports/?id=7 The objective of the analysis is to determine the diagnostic accuracy of single photon emission tomography (SPECT) in the diagnosis of coronary artery disease (CAD) compared to the reference standard of coronary angiography (CA). The analysis is primarily meant to allow for indirect comparisons between non-invasive strategies for the diagnosis of CAD, using CA as a reference standard. SPECT: Cardiac SPECT, or myocardial perfusion scintigraphy (MPS), is a widely used nuclear, non-invasive image acquisition technique for investigating ischemic heart disease. SPECT is currently appropriate for all aspects of detecting and managing ischemic heart disease including diagnosis, risk assessment/stratification, assessment of myocardial viability, and the evaluation of left ventricular function. Myocardial perfusion scintigraphy was originally developed as a two-dimensional planar imaging technique, but SPECT acquisition has since become the clinical standard in current practice. Cardiac SPECT for the diagnosis of CAD uses an intravenously administered radiopharmaceutical tracer to evaluate regional coronary blood flow usually at rest and after stress. The radioactive tracers thallium (201Tl) or technetium-99m (99mTc), or

  4. PET and Single-Photon Emission Computed Tomography in Brain Concussion.

    Science.gov (United States)

    Raji, Cyrus A; Henderson, Theodore A

    2018-02-01

    This article offers an overview of the application of PET and single photon emission computed tomography brain imaging to concussion, a type of mild traumatic brain injury and traumatic brain injury, in general. The article reviews the application of these neuronuclear imaging modalities in cross-sectional and longitudinal studies. Additionally, this article frames the current literature with an overview of the basic physics and radiation exposure risks of each modality. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Single photon emission computed tomography using perfusion tracers in seizure disorders.

    Science.gov (United States)

    Dierckx, R A; Vandevivere, J; Dom, L; Melis, K; Janssens, G; Dobbeleir, A; De Deyn, P P

    1992-07-01

    Single photon emission computed tomography (SPECT) using perfusion tracers makes it possible to estimate regional cerebral blood flow (rCBF) and, indirectly, local brain metabolism. It may be possible to detect and follow physiopathological alterations, such as may be seen in seizure disorders. The authors review the principles of and some data on perfusion SPECT in seizure disorders, stress advantages as well as major drawbacks and add their initial experience with Tc-99m hexamethylpropyleneamine oxime (HMPAO) SPECT in febrile convulsions.

  6. Hot water epilepsy: Phenotype and single photon emission computed tomography observations

    OpenAIRE

    Mehul Patel; Parthasarathy Satishchandra; Hanumanthapura Aravinda; Bharath, Rose D.; Sanjib Sinha

    2014-01-01

    We studied the anatomical correlates of reflex hot water epilepsy (HWE) using multimodality investigations viz. magnetic resonance imaging (MRI), electroencephalography (EEG), and single photon emission computed tomography (SPECT). Five men (mean age: 27.0 ΁ 5.8 years) with HWE were subjected to MRI of brain, video-EEG studies, and SPECT scan. These were correlated with phenotypic presentations. Seizures could be precipitated in three patients with pouring of hot water over the head and semio...

  7. Monitoring CBF in clinical routine by dynamic single photon emission tomography (SPECT) of inhaled xenon-133

    DEFF Research Database (Denmark)

    Sugiyama, H; Christensen, J; Skyhøj Olsen, T

    1986-01-01

    A very simple and low-cost brain dedicated, rapidly rotating Single Photon Emission Tomograph SPECT is described. Its use in following patients with ischemic stroke is illustrated by two middle cerebral artery occlusion cases, one with persistent occlusion and low CBF in MCA territory, and one...... with early lysis of the occlusion having high CBF (massive luxury perfusion) for some weeks. Evidence of this kind may be essential in the evaluation of therapeutic measures in ischemic stroke....

  8. Evaluation of muscular lesions in connective tissue diseases: thallium 201 muscular scans

    Energy Technology Data Exchange (ETDEWEB)

    Guillet, G.; Guillet, J.; Sanciaume, C.; Maleville, J.; Geniaux, M.; Morin, P.

    1988-04-01

    We performed thallium 201 muscle scans to assess muscular involvement in 40 patients with different connective tissue diseases (7 with dermatomyositis, 7 with systemic lupus erythematosus, 12 with progressive systemic scleroderma, 2 with calcinosis, Raynaud's phenomenon, esophageal involvement, sclerodactyly, and telangiectasia (CREST) syndrome, 3 with monomelic scleroderma, 6 with morphea, and 3 with Raynaud's disease). Only 12 of these patients complained of fatigability and/or myalgia. Electromyography was performed and serum levels of muscle enzymes were measured in all patients. Comparison of thallium 201 exercise recording with the other tests revealed that scan sensitivity is greater than electromyographic and serum muscle enzymes levels. Thallium 201 scans showed abnormal findings in 32 patients and revealed subclinical lesions in 18 patients, while electromyography findings were abnormal in 25 of these 32 patients. Serum enzyme levels were raised in only 8 patients. Thallium 201 scanning proved to be a useful guide for modifying therapy when laboratory data were conflicting. It was useful to evaluate treatment efficacy. Because our data indicate a 100% positive predictive value, we believe that thallium 201 scanning should be advised for severe systemic connective tissue diseases with discordant test results.

  9. Exercise-induced thallium-201 myocardial perfusion defects in angina pectoris without significant coronary artery stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Nakazato, Masayasu; Maruoka, Yuji; Sunagawa, Osahiko; Kinjo, Kunihiko; Tomori, Masayuki; Fukiyama, Koshiro (Ryukyu Univ., Nishihara, Okinawa (Japan). School of Medicine)

    1990-01-01

    We performed exercise thallium-201 myocardial scintigraphy in 32 patients with angina pectoris to study the incidence of perfusion defects, who had no significant organic stenosis on coronary angiography. None of them had myocardial infarction or cardiomyopathy. Thallium-201 myocardial scintigraphy and 12-lead ECG recording were performed during supine bicycle ergometer exercise. Perfusion defects in thallium-201 scintigrams in SPECT images were assessed during visual analysis by two observers. In the coronary angiograms obtained during intravenous infusion of nitroglycerin, the luminal diameter of 75% stenosis or less in the AHA classification was regarded as an insignificant organic stenosis. Myocardial perfusion defects in the thallium-201 scintigrams were detected in eight (25%) of the 32 patients. Six of these eight patients had variant angina documented during spontaneous attacks with ST elevations in standard 12-lead ECGs. Perfusion defects were demonstrated at the inferior or infero-posterior regions in six patients, one of whom had concomitant anteroseptal defect. The defects were not always accompanied by chest pain. All but one patient demonstrating inferior or inferoposterior defects showed ST depression in leads II, III and aV{sub F} on their ECGs, corresponding to inferior wall ischemia. The exception was a case with right bundle branch block. Thus, 25% of the patients with angina pectoris, who had no evidence of significant organic stenosis on their coronary angiograms, exhibited exercise-induced perfusion defects in their thallium-201 scintigrams. Coronary spasms might have caused myocardial ischemia in these patients. (author).

  10. Early and delayed thallium-201 scintigraphy in thyroid nodules: the relationship between early thallium-201 uptake and perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Derebek, E. [Dept. of Nuclear Medicine, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Biberoglu, S. [Dept. of Internal Medicine, Div. of Endocrinology, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Kut, O. [Dept. of Nuclear Medicine, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Yesil, S. [Dept. of Internal Medicine, Div. of Endocrinology, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Saydam, S. [Dept. of Surgery, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Yilmaz, M. [Dept. of Nuclear Medicine, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Yenici, O. [Dept. of Nuclear Medicine, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Igci, E. [Dept. of Radiology, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Gokce, O. [Dept. of Surgery, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Canda, S. [Dept. of Pathology, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Bueyuekgebiz, A. [Dept. of Pediatrics, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Dogan, A.S. [Dept. of Nuclear Medicine, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Durak, H. [Dept. of Nuclear Medicine, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey)

    1996-05-01

    Seventy-six patients with tyroid nodules were studied. Initially, 75 MBq of thallium-201 was injected. The thyroid gland was imaged 15 min (early) and 3 h (delayed) after the injection. Thereafter, 185 MBq technetium-99m pertechnetate was injected. Immediately after the injection, a 1-min perfusion image was acquired, followed by an image at 20 min. Increased early and delayed {sup 201}Tl uptake compared with the contralateral thyroid tissue was adopted as the criterion for malignancy. Sensitivity, specificity and negative predictive values were found to be 85%, 64% and 78%, respectively, in operated patients, but these values were 86%, 87% and 95%, respectively, in the whole group, including patients followed with fine-needle aspiration biopsy. With the purpose of investigating the relationship between perfusion and early {sup 201}Tl uptake, bot perfusion and early images were graded comparing nodular activity with contralateral thyroid activity. There was a poor correlation between perfusion and {sup 201}Tl uptake. The correlation was even worse in hyperactive nodules. It is concluded that early and delayed {sup 201}Tl imaging should not be used in the differential diagnosis of cold nodules and that early {sup 201}Tl uptake seems to be more closely related to factors other than perfusion. (orig.)

  11. Surface acoustic wave regulated single photon emission from a coupled quantum dot–nanocavity system

    Energy Technology Data Exchange (ETDEWEB)

    Weiß, M.; Kapfinger, S.; Wixforth, A.; Krenner, H. J., E-mail: hubert.krenner@physik.uni-augsburg.de [Lehrstuhl für Experimentalphysik 1 and Augsburg Centre for Innovative Technologies (ACIT), Universität Augsburg, Universitätsstr. 1, 86159 Augsburg (Germany); Nanosystems Initiative Munich (NIM), Schellingstr. 4, 80799 München (Germany); Reichert, T.; Finley, J. J. [Walter Schottky Institut and Physik Department E24, TU München, Am Coulombwall 4, 85748 Garching (Germany); Nanosystems Initiative Munich (NIM), Schellingstr. 4, 80799 München (Germany); Kaniber, M. [Walter Schottky Institut and Physik Department E24, TU München, Am Coulombwall 4, 85748 Garching (Germany)

    2016-07-18

    A coupled quantum dot–nanocavity system in the weak coupling regime of cavity-quantumelectrodynamics is dynamically tuned in and out of resonance by the coherent elastic field of a f{sub SAW} ≃ 800 MHz surface acoustic wave. When the system is brought to resonance by the sound wave, light-matter interaction is strongly increased by the Purcell effect. This leads to a precisely timed single photon emission as confirmed by the second order photon correlation function, g{sup (2)}. All relevant frequencies of our experiment are faithfully identified in the Fourier transform of g{sup (2)}, demonstrating high fidelity regulation of the stream of single photons emitted by the system.

  12. Surface acoustic wave regulated single photon emission from a coupled quantum dot-nanocavity system

    CERN Document Server

    Weiß, Matthias; Reichert, Thorsten; Finley, Jonathan J; Wixforth, Achim; Kaniber, Michael; Krenner, Hubert J

    2016-01-01

    A coupled quantum dot--nanocavity system in the weak coupling regime of cavity quantumelectrodynamics is dynamically tuned in and out of resonance by the coherent elastic field of a $f_{\\rm SAW}\\simeq800\\,\\mathrm{MHz}$ surface acoustic wave. When the system is brought to resonance by the sound wave, light-matter interaction is strongly increased by the Purcell effect. This leads to a precisely timed single photon emission as confirmed by the second order photon correlation function $g^{(2)}$. All relevant frequencies of our experiment are faithfully identified in the Fourier transform of $g^{(2)}$, demonstrating high fidelity regulation of the stream of single photons emitted by the system. The implemented scheme can be directly extended to strongly coupled systems and acoustically drives non-adiabatic entangling quantum gates based on Landau-Zener transitions.

  13. Single-Photon Emission Computerized Tomography (SPECT in Neuropsychiatry: A Review

    Directory of Open Access Journals (Sweden)

    B. K. Puri

    1992-01-01

    Full Text Available Cranial single-photon emission computerized tomography (SPECT or SPET can now give regional cerebral blood flow images with a resolution approaching that of positron emission tomography (PET. In this paper, the use of high resolution SPECT neuroimaging in neuropsychiatric disorders, including Alzheimer's disease, multi-infarct dementia, Pick's disease, progressive supranuclear palsy, Korsakoff's psychosis, Creutzfeld-Jakob disease, Parkinson's disease, Huntington's disease, schizophrenia, mood disorders, obsessive–compulsive disorder, HIV infection and AIDS is reviewed. Finally, further potential research and clinical uses, based on ligand studies, are outlined.

  14. Advances in Single-Photon Emission Computed Tomography Hardware and Software.

    Science.gov (United States)

    Piccinelli, Marina; Garcia, Ernest V

    2016-02-01

    Nuclear imaging techniques remain today's most reliable modality for the assessment and quantification of myocardial perfusion. In recent years, the field has experienced tremendous progress both in terms of dedicated cameras for cardiac applications and software techniques for image reconstruction. The most recent advances in single-photon emission computed tomography hardware and software are reviewed, focusing on how these improvements have resulted in an even more powerful diagnostic tool with reduced injected radiation dose and acquisition time. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Painful spondylolysis or spondylolisthesis studied by radiography and single-photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Collier, B.D.; Johnson, R.P.; Carrera, G.F.; Meyer, G.A.; Schwab, J.P.; Flatley, T.J.; Isitman, A.T.; Hellman, R.S.; Zielonka, J.S.; Knobel, J.

    1985-01-01

    Planar bone scintigraphy (PBS) and single-photon emission computed tomography (SPECT) were compared in 19 adults with radiographic evidence of spondylolysis and/or spondylolisthesis. SPECT was more sensitive than PBS when used to identify symptomatic patients and sites of painful defects in the pars interarticularis. In addition, SPECT allowed more accurate localization than PBS. In 6 patients, spondylolysis or spondylolisthesis was unrealted to low back pain, and SPECT images of the posterior neural arch were normal. The authors conclude that when spondylolysis or spondylolisthesis is the cause of low back pain, pars defects are frequently heralded by increased scintigraphic activity which is best detected and localized by SPECT.

  16. Evaluation of a 99Tcm bound brain scanning agent for single photon emission computed tomography

    DEFF Research Database (Denmark)

    Andersen, A R; Hasselbalch, S G; Paulson, O B

    1986-01-01

    D,L HM-PAO-99Tcm (PAO) is a lipophilic tracer complex which is avidly taken up by the brain. We have compared the regional distribution of PAO with regional cerebral blood flow (CBF). CBF was measured by single photon emission computed tomography (SPECT) by Tomomatic 64 after 133Xe inhalation in 41...... patients. With the same SPECT the distribution of PAO was measured after intravenous injection. High resolution (HR) and low resolution (LR) studies were performed yielding a resolution of 6-10 mm (HR) and 15-20 mm (LR). PAO images showed close resemblance to 133Xe CBF tomograms. Only 20 per cent...

  17. Single photon image from position emission tomography with insertable collimator for boron neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Joo Young; Yoo, Do Kun; Suh, Tae Suk [Dept. of Biomedical Engineering and Research Institute of Biomedical Engineering, College of Medicine, Catholic University of Korea, Seoul (Korea, Republic of); Hong, Key Jo [Molecular Imaging Program at Stanford (MIPS), Dept. of Radiology, Stanford University, Stanford (United States)

    2014-04-15

    The aim of our proposed system is to confirm the feasibility of extraction of two types of images from one positron emission tomography (PET) module with an insertable collimator for brain tumor treatment during the boron neutron capture therapy (BNCT). The BNCT theory and conceptual diagram of our proposed system are shown fig.1. Data from the PET module, neutron source, and collimator was entered in the Monte Carlon-particle extende source code. We attempted to acquire the PET and SPECT images simultaneously using only PET without an additional isotope. Single photon images were acquired using an insertable collimator on a PET detector.

  18. New CZT cardiac cameras and myocardial perfusion imaging with thallium 201; Nouvelles cameras cardiaques a semi-conducteur cadmium -zinc- telluride (CZT) et scintigraphies myocardiques au thallium 201

    Energy Technology Data Exchange (ETDEWEB)

    Songy, B. [Service de medecine et imagerie nucleaire, centre cardiologique du Nord (CCN), 93 - Saint-Denis (France)

    2010-08-15

    Myocardial perfusion imaging is widely used for management of coronary artery disease. However, it suffers from technical limitations. New cardiac cameras using CZT detectors are now available and increase spatial (x2) and energy (x2) resolutions and photons sensitivity (x5). We describe here the General Electric Discovery NM 530c new camera and summarize the validation studies with technetium agents and with thallium 201, protocols to reduce doses, ultrafast protocols and perspectives offered with this new technology. (author)

  19. Imaging of McCune-Albright syndrome using bone single photon emission computed tomography.

    Science.gov (United States)

    Kairemo, K J; Verho, S; Dunkel, L

    1999-02-01

    McCune-Albright syndrome is a rare disorder caused by a somatic, constitutively activating mutation in the gene (GNAS1) encoding the subunit of the signal transducing guanine nucleotide binding protein (G protein). The condition is characterized by polyostotic fibrous dysplasia, cafe-au-lait pigmentation and multiple endocrine hyperfunction, most commonly gonadotropin-independent precocious puberty in girls. Our patient, a 16-year-old male, with radiologically confirmed polyostotic fibrous dysplasia in cranium, thoracic and pelvic girdles, spine and extremities was studied using planar 99mTc-hydroxymethyldiphosphonate bone scintigraphy and single photon emission computed tomography. Using bone scintigraphy, an unusually extensive and asymmetric fibrous dysplasia was observed in the cranium, face, ribs, femur, humerus, ulna, tibia and the vertebral column, all on the left side. The whole body scan revealed only a few foci on the right side. Single photon emission computed tomography demonstrated extensive unilateral involvement in the base of the skull, facial bones, maxilla and mandible. All the lesions reached only the midline. These findings formed the basis of further treatment, eg. reconstructive surgery of facial asymmetry. McCune-Albright syndrome should be considered in the differential diagnosis when interpreting extensive unilateral predominance in paediatric bone scans.

  20. DE-BLURRING SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY IMAGES USING WAVELET DECOMPOSITION

    Directory of Open Access Journals (Sweden)

    Neethu M. Sasi

    2016-02-01

    Full Text Available Single photon emission computed tomography imaging is a popular nuclear medicine imaging technique which generates images by detecting radiations emitted by radioactive isotopes injected in the human body. Scattering of these emitted radiations introduces blur in this type of images. This paper proposes an image processing technique to enhance cardiac single photon emission computed tomography images by reducing the blur in the image. The algorithm works in two main stages. In the first stage a maximum likelihood estimate of the point spread function and the true image is obtained. In the second stage Lucy Richardson algorithm is applied on the selected wavelet coefficients of the true image estimate. The significant contribution of this paper is that processing of images is done in the wavelet domain. Pre-filtering is also done as a sub stage to avoid unwanted ringing effects. Real cardiac images are used for the quantitative and qualitative evaluations of the algorithm. Blur metric, peak signal to noise ratio and Tenengrad criterion are used as quantitative measures. Comparison against other existing de-blurring algorithms is also done. The simulation results indicate that the proposed method effectively reduces blur present in the image.

  1. Genotoxic and mutagenic effects of the diagnostic use of thallium-201 in nuclear medicine

    Energy Technology Data Exchange (ETDEWEB)

    Kelsey, K.T. (Harvard School of Public Health, Boston, MA (United States)); Donohoe, K.J. (Beth Israel Hospital, Boston, MA (United States). Div. of Nuclear Medicine); Baxter, Barbara; Memisoglu, Asli; Little, J.B.; Caggana, Michele; Liber, H.L. (Harvard School of Public Health, Boston, MA (United States))

    1991-07-01

    In order to investigate possible mutagenetic effects of in vivo exposure to low levels of ionizing radiation used in nuclear medicine, the authors examined hypoxanthine guanine phosphoribosyl transferase (hprt) mutant fraction (MF) and chromosome aberration (CA) frequency in 24 nuclear medicine patients before and after injection of thallium-201. The mean MF of the thallium-201-exposed cohort was 5.2{+-}4.4 x 10{sup -6} before injection exposure. No significant difference in MF was observed 24 h later. In 11 patients who were studied on a 3rd occasion, 30 days after thallium-201 exposure, there was again no significant difference in post-exposure as compared with the pre-exposure MF. The frequency of CA in peripheral blood lymphocytes was not significantly different, comparing pre- and 24h to 1 month post-radionuclide exposure . Thus, thallium-201 exposure was not associated with significant elevations in MF or CA frequency in lymphocytes of exposed individuals. (author). 40 refs.; 3 tabs.

  2. Clinical features and applications of thallium-201. With reference to scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Tadashige

    1988-12-01

    Thallium-201 is not only used widely in myocardial imaging but also has a great potential in other various nuclear medicine imaging studies. This paper presents clinical features and applications of thallium-201, focusing on clinical trials with thallium-201 at the Shinshu University School of Medicine. Thallium-201 myocardial scintigraphy offers information on (1) ventricular position and morphology, (2) hypertrophy or dilatation of the left ventricle, (3) hypertrophy or dilatation of the right ventricle, (4) site and extent of myocardial ischemia and infarct, (5) myocardial blood flow, (6) pulmonary congestion or interstitial pulmonary edema, and (7) pericardial effusion. It can be used in the following evaluation or diagnosis: (1) acute or old myocardial infarction, (2) angina pectoris, (3) treatment strategy or prognosis of ischemic heart disease, (4) treatment strategy or observation of bypass graft or drug therapy, (5) hypertrophic or dilated idiopathic cardiomyopathy, (6) myocardial lesions induced by sarcoidosis, collagen disease, and neuro-muscular disease, (7) ventricular hypertrophy and pulmonary edema, and (9) pericarditis, pericardial effusion, and systolic pericarditis associated with underlying disease. The significance of tumor, liver, bone marrow scintigraphies is also referred to. (Namekawa, K) 69 refs.

  3. Single-photon emission associated with double electron capture in F9+ + C collisions

    CERN Document Server

    Elkafrawy, Tamer; Tanis, John A; Warczak, Andrzej

    2016-01-01

    Radiative double electron capture (RDEC), the one-step process occurring in ion-atom collisions, has been investigated for bare fluorine ions colliding with carbon. RDEC is completed when two target electrons are captured to a bound state of a projectile simultaneously with the emission of a single photon. This work is a follow-up to our earlier measurement of RDEC for bare oxygen projectiles, thus providing a recipient system free of electron-related Coulomb fields in both cases and allowing for the comparison between the two collision systems as well as with available theoretical studies. The most significant mechanisms of x-ray emission that may contribute to the RDEC energy region as background processes are also addressed.

  4. Effects of adenosine and a selective A2A adenosine receptor agonist on hemodynamic and thallium-201 and technetium-99m-sestaMIBI biodistribution and kinetics.

    Science.gov (United States)

    Mekkaoui, Choukri; Jadbabaie, Farid; Dione, Donald P; Meoli, David F; Purushothaman, Kailasnath; Belardinelli, Luiz; Sinusas, Albert J

    2009-10-01

    The purpose of this study was to compare a selective A(2A) adenosine receptor agonist (regadenoson) with adenosine in clinically relevant canine models with regard to effects on hemodynamics and thallium-201 ((201)Tl) and technetium-99m ((99m)Tc)-sestaMIBI biodistribution and kinetics. The clinical application of vasodilator stress for perfusion imaging requires consideration of the effects of these vasodilating agents on systemic hemodynamics, coronary flow, and radiotracer uptake and clearance kinetics. Sequential imaging and arterial blood sampling was performed on control, anesthetized closed-chest canines (n = 7) to evaluate radiotracer biodistribution and kinetics after either a bolus administration of regadenoson (2.5 microg/kg) or 4.5-min infusion of adenosine (280 microg/kg). The effects of regadenoson on coronary flow and myocardial radiotracer uptake were then evaluated in an open-chest canine model of a critical stenosis (n = 7). Results from ex vivo single-photon emission computed tomography were compared with tissue well-counting. The use of regadenoson compared favorably with adenosine in regard to the duration and magnitude of the hemodynamic effects and the effect on (201)Tl and (99m)Tc-sestaMIBI biodistribution and kinetics. The arterial blood clearance half-time was significantly faster for (99m)Tc-sestaMIBI (regadenoson: 1.4 +/- 0.03 min; adenosine: 1.5 +/- 0.08 min) than for (201)Tl (regadenoson: 2.5 +/- 0.16 min, p adenosine: 2.7 +/- 0.04 min, p regadenoson stress was significantly greater than the relative perfusion defect with (99m)Tc-sestaMIBI (0.69 +/- 0.03%, p regadenoson produced a hyperemic response comparable to a standard infusion of adenosine. The biodistribution and clearance of both (201)Tl and (99m)Tc-sestaMIBI during regadenoson were similar to adenosine vasodilation. Ex vivo perfusion images under the most ideal conditions permitted detection of a critical stenosis, although (201)Tl offered significant advantages over (99m

  5. Comparison of 8-frame and 16-frame thallium-201 gated myocardial perfusion SPECT for determining left ventricular systolic and diastolic parameters.

    Science.gov (United States)

    Kurisu, Satoshi; Sumimoto, Yoji; Ikenaga, Hiroki; Watanabe, Noriaki; Ishibashi, Ken; Dohi, Yoshihiro; Fukuda, Yukihiro; Kihara, Yasuki

    2017-07-01

    The myocardial perfusion single photon emission computed tomography synchronized with the electrocardiogram (gated SPECT) has been widely used for the assessment of left ventricular (LV) systolic and diastolic functions using Quantitative gated SPECT. The aim of this study was to compare the effects of 8-frame and 16-frame thallium-201 (Tl-201) gated SPECT for determining LV systolic and diastolic parameters. The study population included 42 patients with suspected coronary artery disease who underwent gated SPECT by clinical indication. LV systolic and diastolic parameters were assessed on 8-frame and 16-frame gated SPECT. There were good correlations in end-diastolic volume (r = 0.99, p < 0.001), end-systolic volume (ESV) (r = 0.97, p < 0.001) and ejection fraction (EF) (r = 0.95, p < 0.001) between 8-frame and 16-frame gated SPECT. Bland-Altman plot showed a significant negative slope of -0.08 in EDV indicating a larger difference for larger EDV. Eight-frame gated SPECT overestimated ESV by 2.3 ml, and underestimated EF by -4.2% than 16-frame gated SPECT. There were good correlations in peak filling rate (PFR) (r = 0.87, p < 0.001), one third mean filling rate (r = 0.87, p < 0.001) and time to PFR (r = 0.61, p < 0.001) between 8-frame and 16-frame gated SPECT. Eight-frame gated SPECT underestimated PFR by -0.22 than 16-frame gated SPECT. Eight-frame gated SPECT estimated as much MFR/3 and TPFR as 16-frame gated SPECT. According to the data, the study suggested that 8-frame Tl-201 gated SPECT could underestimate systolic and/or diastolic parameter when compared with 16-frame gated SPECT.

  6. Aphasia following left thalamic hemorrhage. A study by Western Aphasia Battery and single photon emission CT

    Energy Technology Data Exchange (ETDEWEB)

    Makishita, Hideo; Miyasaka, Motomaro; Tanizaki, Yoshio; Yanagisawa, Nobuo; Sugishita, Morihiro

    1984-07-01

    A report is given of 7 patients with left thalamic hemorrhage in the chronic stage (from 1.5 months to 4.5 months) in which language disorders were examined by Western Aphasia Battery (WAB) and cerebral blood flow was measured by single photon emission CT. Examination of language by WAB revealed 4 aphasics out of 7 cases, and 3 patients had no language deficit. The patient with Wernicke's aphasia showed low density area only in the left posterior thalamus in X-ray CT, and revealed severe low blood flow area extending to left temporal lobe in emission CT. In the case with transcortical sensory aphasia, although X-ray CT showed no obvious low density area, emission CT revealed moderate low flow area in the left temporooccipital region and low blood flow at the left thalamus. In one of the two patients classified as anomic aphasia, emission CT showed slight low flow area at the temporo-occipital region similar to the case with transcortical sensory aphasia. In another case with anomic aphasia there was a wide low density area all over the left thalamus and midline shift to the right in X-ray CT, and emission CT showed severe low blood flow in the same region spreading widely toward the cerebral surface. In all of the 3 patients without aphasia, emission CT showed low flow region restricted to the left thalamus.

  7. Technetium-99m hexamethylpropylene amine oxime single photon emission tomography in febrile convulsions.

    Science.gov (United States)

    Dierckx, R A; Melis, K; Dom, L; Janssens, G; Luysterborgh, E; De Deyn, P P; Vandevivere, J

    1992-01-01

    We report our initial experience with technetium-99m hexamethyl propylene amine oxime (99mTC-HMPAO) brain single photon emission tomography (SPET) in the investigation of 19 children presenting with febrile convulsions. Two patients with complex febrile convulsions showed focal SPET lesions contralateral to the neurological deficit. However, in 9 out of 17 patients with simple febrile convulsions, focally disturbed perfusion was shown. In 4 out of 6 patients with electroencephalogram (EEG) abnormalities on admittance, SPET revealed at least 2 focal lesions. The temporofrontal region was the one most commonly involved. The SPET findings presented here also suggest a temporal relationship with the febrile convulsions, with markedly fewer lesions if examined after 12 days. In our initial experience, perfusion SPET did not show any particular pattern helpful in the differential diagnosis of the child presenting with febrile convulsions. Physiopathologically, our findings may support the hypothesis that brain tissue is regionally more vulnerable to fever, in patients presenting with febrile convulsions.

  8. Hot water epilepsy: Phenotype and single photon emission computed tomography observations.

    Science.gov (United States)

    Patel, Mehul; Satishchandra, Parthasarathy; Aravinda, Hanumanthapura; Bharath, Rose D; Sinha, Sanjib

    2014-10-01

    We studied the anatomical correlates of reflex hot water epilepsy (HWE) using multimodality investigations viz. magnetic resonance imaging (MRI), electroencephalography (EEG), and single photon emission computed tomography (SPECT). Five men (mean age: 27.0 ΁ 5.8 years) with HWE were subjected to MRI of brain, video-EEG studies, and SPECT scan. These were correlated with phenotypic presentations. Seizures could be precipitated in three patients with pouring of hot water over the head and semiology of seizures was suggestive of temporal lobe epilepsy. Ictal SPECT showed hyperperfusion in: left medial temporal - one, left lateral temporal - one, and right parietal - one. Interictal SPECT was normal in all five patients and did not help in localization. MRI and interictal EEG was normal in all the patients. The clinical and SPECT studies suggested temporal lobe as the seizure onset zone in some of the patients with HWE.

  9. Hot water epilepsy: Phenotype and single photon emission computed tomography observations

    Directory of Open Access Journals (Sweden)

    Mehul Patel

    2014-01-01

    Full Text Available We studied the anatomical correlates of reflex hot water epilepsy (HWE using multimodality investigations viz. magnetic resonance imaging (MRI, electroencephalography (EEG, and single photon emission computed tomography (SPECT. Five men (mean age: 27.0 ΁ 5.8 years with HWE were subjected to MRI of brain, video-EEG studies, and SPECT scan. These were correlated with phenotypic presentations. Seizures could be precipitated in three patients with pouring of hot water over the head and semiology of seizures was suggestive of temporal lobe epilepsy. Ictal SPECT showed hyperperfusion in: left medial temporal - one, left lateral temporal - one, and right parietal - one. Interictal SPECT was normal in all five patients and did not help in localization. MRI and interictal EEG was normal in all the patients. The clinical and SPECT studies suggested temporal lobe as the seizure onset zone in some of the patients with HWE.

  10. Enhanced single-photon emission from a diamond–silver aperture

    KAUST Repository

    Choy, Jennifer T.

    2011-10-09

    Solid-state quantum emitters, such as the nitrogen-vacancy centre in diamond, are robust systems for practical realizations of various quantum information processing protocols2-5 and nanoscale magnetometry schemes6,7 at room temperature. Such applications benefit from the high emission efficiency and flux of single photons, which can be achieved by engineering the electromagnetic environment of the emitter. One attractive approach is based on plasmonic resonators8-13, in which sub-wavelength confinement of optical fields can strongly modify the spontaneous emission of a suitably embedded dipole despite having only modest quality factors. Meanwhile, the scalability of solid-state quantum systems critically depends on the ability to control such emitterg-cavity interaction in a number of devices arranged in parallel. Here, we demonstrate a method to enhance the radiative emission rate of single nitrogen-vacancy centres in ordered arrays of plasmonic apertures that promises greater scalability over the previously demonstrated bottom-up approaches for the realization of on-chip quantum networks. © 2011 Macmillan Publishers Limited. All rights reserved.

  11. Few-view single photon emission computed tomography (SPECT) reconstruction based on a blurred piecewise constant object model

    DEFF Research Database (Denmark)

    Wolf, Paul A.; Jørgensen, Jakob Sauer; Schmidt, Taly G.

    2013-01-01

    A sparsity-exploiting algorithm intended for few-view Single Photon Emission Computed Tomography (SPECT) reconstruction is proposed and characterized. The algorithm models the object as piecewise constant subject to a blurring operation. To validate that the algorithm closely approximates the true...

  12. Computed tomography angiography and perfusion to assess coronary artery stenosis causing perfusion defects by single photon emission computed tomography

    DEFF Research Database (Denmark)

    Rochitte, Carlos E; George, Richard T; Chen, Marcus Y

    2014-01-01

    AIMS: To evaluate the diagnostic power of integrating the results of computed tomography angiography (CTA) and CT myocardial perfusion (CTP) to identify coronary artery disease (CAD) defined as a flow limiting coronary artery stenosis causing a perfusion defect by single photon emission computed ...

  13. Comparison of planar bone scintigraphy and single photon emission computed tomography in patients suspected of having unilateral condylar hyperactivity

    NARCIS (Netherlands)

    Saridin, C.P.; Raijmakers, P.G.H.M.; Tuinzing, D.B.; Becking, A.G.

    2008-01-01

    Objective A comparison is made of single photon emission computed tomography (SPECT) and planar bone scintigraphy in the diagnosis of patients with suspected unilateral condylar hyperactivity (UCH). Study design The subjects comprised 56 patients with suspected UCH who underwent SPECT and regular

  14. Comparison of planar bone scintigraphy and single photon emission computed tomography in patients suspected of having unilateral condylar hyperactivity

    NARCIS (Netherlands)

    Saridin, Carrol P.; Raijmakers, Pieter G. H. M.; Tuinzing, Dirk B.; Becking, Alfred G.

    2008-01-01

    A comparison is made of single photon emission computed tomography (SPECT) and planar bone scintigraphy in the diagnosis of patients with suspected unilateral condylar hyperactivity (UCH). The subjects comprised 56 patients with suspected UCH who underwent SPECT and regular planar bone scans.

  15. Comparative studies on right ventricular pressure and volume overloading by thallium-201 myocardial scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Owada, K.; Tsukahara, Y.; Kijima, M.; Miyazaki, Y.; Ono, K. (Fukushima Medical Coll. (Japan))

    1982-03-01

    Thallium-201 myocardial scintigraphy was performed in 44 patients with various heart diseases including mitral stenosis, atrial septal defect, primary pulmonary hypertension, and left atrial myxoma. The morphological findings of right ventricular (RV) free wall on the scintigram and RV/IVS (interventricular septum) uptake ratio of the images obtained from the left anterior oblique projection were studied in the patients with RV pressure or volume overloading.

  16. Dipyridamole-thallium-201 tomography documenting improved myocardial perfusion with therapy in Kawasaki disease

    Energy Technology Data Exchange (ETDEWEB)

    Nienaber, C.A.; Spielmann, R.P.; Hausdorf, G.

    1988-12-01

    Thallium-201 tomographic perfusion studies after pharmacologic vasodilation were performed in seven children (aged 2 years 8 months to 8 years 7 months), 3 to 20 months after the acute stage of the disease. In all patients coronary aneurysms were seen on cross-sectional echocardiograms. The scintigrams of six children showed no significant regional reduction of myocardial thallium-201 uptake. These children had remained asymptomatic in the follow-up period after the acute inflammatory stage of Kawasaki disease. Persistent and transient thallium defects were present in one child with acute posterolateral myocardial infarction; obstruction of two coronary vessels supplying the defect zones was confirmed by contrast angiography. After 8 months of treatment a follow-up nuclear scan showed marked reduction in the size of the defect and almost complete abolishment of the ischemic reaction. Thus tomographic thallium-201 perfusion scintigraphy in conjunction with vasodilation stress is useful to assess myocardial perfusion in children with Kawasaki disease and demonstrates marked improvement in regional perfusion after adequate medical therapy.

  17. Detection of human collateral circulation by vasodilation-thallium-201 tomography

    Energy Technology Data Exchange (ETDEWEB)

    Nienaber, C.A.; Salge, D.; Spielmann, R.P.; Montz, R.; Bleifeld, W. (University Hospital Eppendorf, Hamburg (Germany, F.R.))

    1990-04-15

    Coronary arteriolar vasodilation may provoke redistribution of flow to collateral-dependent jeopardized myocardium. To assess the physiologic significance of collaterals, 80 consecutive post-infarction patients (age 58 +/- 8 years) underwent vasodilation-redistribution thallium-201 tomographic imaging after administration of 0.56 mg of intravenous dipyridamole/kg body weight. Circumferential profile analysis of thallium-201 uptake and redistribution in representative left ventricular tomograms provided quantitative assessment of transient and fixed defects and separation between periinfarctional and distant inducible hypoperfusion. Tomographic perfusion data were correlated to wall motion and collateral circulation between distinct anatomic perfusion territories. Patients were grouped according to presence (59%) or absence (41%) of angiographically visible collateral channels to jeopardized myocardium. In the presence of collaterals, distant reversible defects were larger than in absence of collaterals (p less than 0.05); the extent of combined periinfarctional and distant redistribution was also larger in collateralized patients (p less than 0.025), whereas the size of the persistent perfusion defect was similar in both groups. By prospective analysis the tomographic perfusion pattern of combined periinfarctional and distant redistribution revealed a sensitivity of 85% and a specificity of 78% for the detection of significant collateral circulation in this group of patients. Thus, using the exhausted flow reserve as a diagnostic tool, vasodilation-thallium-201 tomography has the potential to identify and quantitate collateralized myocardium in post-infarction patients and may guide diagnostic and therapeutic decision-making.

  18. Massively parallel computers for 3D single-photon-emission computed tomography.

    Science.gov (United States)

    Butler, C S; Miller, M I; Miller, T R; Wallis, J W

    1994-03-01

    Since the introduction of the expectation-maximization (EM) algorithm for generating maximum-likelihood (ML) and maximum a posteriori (MAP) estimates in emission tomography, there have been many investigators applying the ML method. However, almost all of the previous work has been restricted to two-dimensional (2D) reconstructions. The major focus and contribution of this paper is to demonstrate a fully three-dimensional (3D) implementation of the MAP method for single-photon-emission computed tomography (SPECT). The 3D reconstruction exhibits an improvement in resolution when compared to the generation of the series of separate 2D slice reconstructions. As has been noted, the iterative EM algorithm for 2D reconstruction is highly computational; the 3D algorithm is far worse. To accommodate the computational complexity, we have extended our previous work in the 2D arena and demonstrate an implementation on the class of massively parallel processors of the 3D algorithm. Using a 16000 processor MasPar machine, the algorithm is demonstrated to execute at 1.24 s/EM iteration for the entire 64 x 64 x 64 cube of 64 planar measurements obtained from the Siemens Orbiter rotating camera operating in the high-resolution mode.

  19. Single-photon emission at 1.5 μm from an InAs/InP quantum dot with highly suppressed multi-photon emission probabilities

    Science.gov (United States)

    Miyazawa, T.; Takemoto, K.; Nambu, Y.; Miki, S.; Yamashita, T.; Terai, H.; Fujiwara, M.; Sasaki, M.; Sakuma, Y.; Takatsu, M.; Yamamoto, T.; Arakawa, Y.

    2016-09-01

    We have demonstrated highly pure single-photon emissions from an InAs/InP quantum dot at the wavelength of 1.5 μm. By applying quasi-resonant excitation, one exciton is deterministically generated in an excited state, which then relaxes to the exciton ground state before recombining to emit a single photon. The photon-correlation function of the emission from the exciton ground state exhibits a record g(2)(0) value of (4.4 ± 0.2) × 10-4 measured using high-performance super-conducting single-photon detectors, without any background subtraction. This single-photon source with extremely low multi-photon emission probability paves the way to realize long distance quantum key distribution and low error-rate quantum computation.

  20. Attenuation correction in pulmonary and myocardial single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Almquist, H

    2000-01-01

    The objective was to develop and validate methods for single photon emission computed tomography, SPECT, allowing quantitative physiologic and diagnostic studies of lung and heart. A method for correction of variable attenuation in SPECT, based on transmission measurements before administration of an isotope to the subject, was developed and evaluated. A protocol based upon geometrically well defined phantoms was developed. In a mosaic pattern phantom count rates were corrected from 39-43% to 101-110% of reference. In healthy subjects non-gravitational pulmonary perfusion gradients observed without attenuation correctionwere artefacts caused by attenuation. Pulmonary density in centre of right lung, obtained from the transmission measurement, was 0.28 {+-} 0.03 g/ml in normal subjects. Mean density was lower in large lungs compared to smaller ones. We also showed that regional ventilation/perfusion ratios could be measured with SPECT, using the readily available tracer {sup 133}Xe. Because of the low energy of {sup 133}Xe this relies heavily upon attenuation correction. A commercially available system for attenuation correction with simultaneous emission and transmission, considered to improve myocardial SPECT, performed erroneously. This could lead to clinical misjudgement. We considered that manufacturer-independent pre-clinical tests are required. In a test of two other commercial systems, based on different principles, an adapted variant of our initial protocol was proven useful. Only one of the systems provided correct emission count rates independently on phantom configuration. Errors in the other system were related to inadequate compensation of the influence of emission activity on the transmission study.

  1. QUANTUM CRYPTOGRAPHY: Single Photons.

    Science.gov (United States)

    Benjamin, S

    2000-12-22

    Quantum cryptography offers the potential of totally secure transfer of information, but as Benjamin discusses in this Perspective, its practical implementation hinges on being able to generate single photons (rather than two or more) at a time. Michler et al. show how this condition can be met in a quantum dot microdisk structure. Single molecules were also recently shown to allow controlled single-photon emission.

  2. Highly polarized electrically driven single-photon emission from a non-polar InGaN quantum dot

    Science.gov (United States)

    Kocher, C. C.; Puchtler, T. J.; Jarman, J. C.; Zhu, T.; Wang, T.; Nuttall, L.; Oliver, R. A.; Taylor, R. A.

    2017-12-01

    Nitride quantum dots are well suited for the deterministic generation of single photons at high temperatures. However, this material system faces the challenge of large in-built fields, decreasing the oscillator strength and possible emission rates considerably. One solution is to grow quantum dots on a non-polar plane; this gives the additional advantage of strongly polarized emission along one crystal direction. This is highly desirable for future device applications, as is electrical excitation. Here, we report on electroluminescence from non-polar InGaN quantum dots. The emission from one of these quantum dots is studied in detail and found to be highly polarized with a degree of polarization of 0.94. Single-photon emission is achieved under excitation with a constant current giving a g(2 )(0 ) correlation value of 0.18. The quantum dot electroluminescence persists up to temperatures as high as 130 K.

  3. Single-photon emission computed tomographic findings and motor neuron signs in amyotrophic lateral sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Terao, Shin-ichi; Sobue, Gen; Higashi, Naoki; Takahashi, Masahiko; Suga, Hidemichi; Mitsuma, Terunori [Aichi Medical Univ., Nagakute (Japan)

    1995-03-01

    {sup 123}I-amphetamine-single photon emission computed tomography (SPECT) was performed on 16 patients with amyotrophic lateral sclerosis (ALS) to investigate the correlation between regional cerebral blood flow (rCBF) and upper motor neuron signs. Significant decreased blood flow less than 2 SDs below the mean of controls was observed in the frontal lobe in 4 patients (25%) and in the frontoparietal lobe including the cortical motor area in 4 patients, respectively. The severity of extermity muscular weakness was significantly correlate with decrease in blood flow through the frontal lobe (p<0.05) and through the frontoparietal lobe (p<0.001). A significant correlation was also noted to exist between the severity of bulbar paralysis and decrease in blood flow through the frontoparietal lobe. No correlation, however, was observed between rCBF and severity of spasticity, presence or absence of Babinski`s sign and the duration of illness. Although muscular weakness in the limbs and bulbar paralysis are not pure upper motor neuron signs, the observed reduction in blood flow through the frontal or frontoparietal lobes appears to reflect extensive progression of functional or organic lesions of cortical neurons including the motor area. (author).

  4. Single photon emission computed tomography in the diagnosis of Alzheimer`s disease

    Energy Technology Data Exchange (ETDEWEB)

    Hanyu, Haruo; Asano, Tetsuichi; Abe, Shin`e; Arai, Hisayuki; Iwamoto, Toshihiko; Takasaki, Masaru; Shindo, Hiroaki; Abe, Kimihiko [Tokyo Medical Coll. (Japan)

    1997-06-01

    Studies with single photon emission computed tomography (SPECT) have shown temporoparietal (TP) hypoperfusion in patients with Alzheimer`s disease (AD). We evaluated the utility of this findings in the diagnosis of AD. SPECT images with {sup 123}I-iodoamphetamine were analyzed qualitatively by a rater without knowledge of the subject`s clinical status. Sixty-seven of 302 consecutive patients were judged as having TP hypoperfusion by SPECT imaging. This perfusion pattern was observed in 44 of 51 patients with AD, in 5 with mixed dementia, 8 with cerebrovascular disease (including 5 with dementia), 4 with Parkinson`s disease (including 2 with dementia), 1 with normal pressure hydrocephalus, 1 with slowly progressive aphasia, 1 with progressive autonomic failure, 2 with age-associated memory impairment, and 1 with unclassified dementia. The sensitivity for AD was 86.3% (44 of 51 AD), and the specificity was 91.2% (229 of 251 non-AD). Next, we looked for differences in perfusion images between patients with AD and without AD. Some patients without AD had additional hypoperfusion beyond TP areas: deep gray matter hypoperfusion and diffuse frontal hypoperfusion, which could be used to differentiate them from the patients with AD. Others could not be distinguished from patients with AD by their perfusion pattern. Although patients with other cerebral disorders occasionally have TP hypoperfusion, this finding makes the diagnosis of AD very likely. (author)

  5. Bone single photon emission computed tomography (SPECT in a patient with Pancoast tumor: a case report

    Directory of Open Access Journals (Sweden)

    Hamid Javadi

    Full Text Available CONTEXT: Non-small cell lung carcinomas (NSCLCs of the superior sulcus are considered to be the most challenging type of malignant thoracic disease. In this disease, neoplasms originating mostly from the extreme apex of the lung expand to the chest wall and thoracic inlet structures. Multiple imaging procedures have been applied to identify tumors and to stage and predict tumor resectability in surgical operations. Clinical examinations to localize pain complaints in shoulders and down the arms, and to screen for Horner's syndrome and abnormalities seen in paraclinical assessments, have been applied extensively for differential diagnosis of superior sulcus tumors. Although several types of imaging have been utilized for diagnosing and staging Pancoast tumors, there have been almost no reports on the efficiency of whole-body bone scans (WBBS for detecting the level of abnormality in cases of superior sulcus tumors. CASE REPORT: We describe a case of Pancoast tumor in which technetium-99m methylene diphosphonate (Tc-99m MDP bone single-photon emission-computed tomography (SPECT was able to accurately detect multiple areas of abnormality in the vertebrae and ribs. In describing this case, we stress the clinical and diagnostic points, in the hope of stimulating a higher degree of suspicion and thereby facilitating appropriate diagnosis and treatment. From the results of this study, further clinical trials to evaluate the potential of SPECT as an efficient imaging tool for the work-up on cases of Pancoast tumor are recommended.

  6. Dilatation of the left ventricular cavity on dipyridamole thallium-201 imaging: A new marker of triple-vessel disease

    Energy Technology Data Exchange (ETDEWEB)

    Takeishi, Y.; Tono-oka, I.; Ikeda, K.; Komatani, A.; Tsuiki, K.; Yasui, S. (Yamagata Univ. School of Medicine (Japan))

    1991-02-01

    To investigate the significance and mechanism of dilatation of the left ventricular cavity on dipyridamole thallium-201 imaging, we performed both dipyridamole thallium-201 imaging and dipyridamole radionuclide angiography on 83 patients with known angiograms. The dipyridamole/delayed ratio of the left ventricular dimension from the thallium-201 image was defined as the left ventricular dilatation ratio (LVDR). An LVDR greater than the mean + two standard deviations in patients without coronary artery disease was defined as abnormal. Twenty-two of 83 patients showed an abnormal LVDR, and 18 of the 22 patients (82%) had triple-vessel disease. By defect and washout analysis, the sensitivity and specificity for correctly identifying the patients as having triple-vessel disease was 72% and 76%, respectively, whereas LVDR had a sensitivity of 72% and a specificity of 93%. When LVDR was used in combination with the defect and washout criteria, sensitivity increased to 84% without a loss of specificity. In those 22 patients with abnormal LVDRs, end-diastolic volume measured by radionuclide angiography did not change after dipyridamole infusion. Dilatation of the left ventricular cavity on dipyridamole thallium-201 imaging reflected relative subendocardial hypoperfusion induced by dipyridamole rather than actual chamber enlargement. The LVDR was moderately sensitive and highly specific for triple-vessel disease and provided complementary information to dipyridamole thallium-201 imaging.

  7. Safety of ventilation/perfusion single photon emission computed tomography for pulmonary embolism diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Le Roux, Pierre-Yves; Palard, Xavier; Robin, Philippe; Abgral, Ronan; Querellou, Solene; Salaun, Pierre-Yves [Universite Europeenne de Bretagne, Brest (France); Universite de Brest, Brest (France); CHRU de la Cavale Blanche, Service de medecine nucleaire, Brest (France); Delluc, Aurelien; Couturaud, Francis [Universite Europeenne de Bretagne, Brest (France); Universite de Brest, Brest (France); CHRU de la Cavale Blanche, Departement de medecine interne et de pneumologie, Brest (France); Le Gal, Gregoire [Universite Europeenne de Bretagne, Brest (France); University of Ottawa, Ottawa Hospital Research Institute, Ottawa (Canada); CHRU de la Cavale Blanche, Departement de medecine interne et de pneumologie, Brest (France); Universite de Brest, Brest (France)

    2014-10-15

    The aim of this management outcome study was to assess the safety of ventilation/perfusion single photon emission computed tomography (V/Q SPECT) for the diagnosis of pulmonary embolism (PE) using for interpretation the criteria proposed in the European Association of Nuclear Medicine (EANM) guidelines for V/Q scintigraphy. A total of 393 patients with clinically suspected PE referred to the Nuclear Medicine Department of Brest University Hospital from April 2011 to March 2013, with either a high clinical probability or a low or intermediate clinical probability but positive D-dimer, were retrospectively analysed. V/Q SPECT were interpreted by the attending nuclear medicine physician using a diagnostic cut-off of one segmental or two subsegmental mismatches. The final diagnostic conclusion was established by the physician responsible for patient care, based on clinical symptoms, laboratory test, V/Q SPECT and other imaging procedures performed. Patients in whom PE was deemed absent were not treated with anticoagulants and were followed up for 3 months. Of the 393 patients, the prevalence of PE was 28 %. V/Q SPECT was positive for PE in 110 patients (28 %) and negative in 283 patients (72 %). Of the 110 patients with a positive V/Q SPECT, 78 (71 %) had at least one additional imaging test (computed tomography pulmonary angiography or ultrasound) and the diagnosis of PE was eventually excluded in one patient. Of the 283 patients with a negative V/Q SPECT, 74 (26 %) patients had another test. The diagnosis of PE was finally retained in one patient and excluded in 282 patients. The 3-month thromboembolic risk in the patients not treated with anticoagulants was 1/262: 0.38 % (95 % confidence interval 0.07-2.13). A diagnostic management including V/Q SPECT interpreted with a diagnostic cut-off of ''one segmental or two subsegmental mismatches'' appears safe to exclude PE. (orig.)

  8. Proton magnetic resonance spectroscopy and single photon emission CT in patients with olivopontocerebellar atrophy

    Energy Technology Data Exchange (ETDEWEB)

    Ikuta, Naomi [Yamaguchi Univ., Ube (Japan). School of Medicine

    1998-04-01

    Using proton magnetic resonance spectroscopy ({sup 1}H-MRS) and single photon emission CT (SPECT), the cerebellum of patients with olivopontocerebellar atrophy (OPCA) and of age-matched control subjects was studied. A spectrum was collected from a 27 cm{sup 3} (3 x 3 x 3 cm) voxel in the cerebellum containing white and gray matters in order to measure the distribution and relative signal intensities of N-acetylaspartate (NAA), creatine (Cre) and choline (Cho). In the cerebellum of the patients with OPCA, mean NAA/Cre ratios for OPCA patients were significantly decreased compared with normal control subjects (OPCA, 1.01{+-}0.247; controls, 1.526{+-}0.144: p<0.001). Mean NAA/Cho ratios for OPCA patients were slightly decreased (OPCA, 1.285{+-}0.228; controls 1.702{+-}0.469: p<0.06). Cho/Cre ratios valued in the cerebellum of OPCA patients were not significantly different from those in normal controls (OPCA, 0.793{+-}0.186; controls, 0.946{+-}0.219). The ratio of RI count in the cerebellum to that in the occipital lobe was significantly decreased in OPCA patients (OPCA, 0.947{+-}0.096; controls, 1.06{+-}0.063: p<0.01). Cerebellar signs were assessed including gait ataxia, limb ataxia, dysarthria, saccadic pursuit, and nystagmus separately or in combination. In patients with more severe ataxic gait and dysarthria, MRS revealed slightly lowered NAA/Cre ratio. There was no significant correlation between NAA/Cre ratio and severity of other clinical signs. The MRS and SPECT findings give a confirmative evidence of hypofunction in cerebellum of patients with OPCA. (author)

  9. Determination of left ventricular mass in man using single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Wolfe, C.L.; Jansen, D.E.; Corbett, J.R.; Willerson, J.T.; Lipscomb, K.; Redish, G.; Filipchuk, N.; Gabliani, G.; Lewis, S.E.

    1984-01-01

    The measurement of viable left ventricular (LV) mass may have important prognostic significance in patients with ischemic heart disease or hypertrophic heart disease. To test the hypothesis that single photon emission computed tomography (SPECT) could accurately determine LV mass in man, the authors compared SPECT measurements of LV mass to LV mas determined by cineangiography in 12 patients with normal coronary arteries and normal LV functions. Repeat SPECT determinations of LV mass were carried out in 5 patients. Each patient was injected with 2 to 2.4 mCi of thallium (T1)-201 in the resting state. Projection images (64x64) containing a minimum of 80,000 counts were acquired at 6-degree intervals over 180-degrees using a rotating gamma camera. Transverse sections were reconstructed by filtered backprojection. The boundary of LV uptake of T1-201 in each transverse section was defined using a simple three-dimensional threshold detector. The total number of voxels demonstrating LV T1-201 uptake was multiplied by the voxel volume and the specific gravity of myocardium (1.05g/cc). Cath determinations of LV mass were made from end diastolic frames of a biplane left ventriculogram using the method of a previous study. There was good correlation between LV mass determined by SPECT and by cineangiography. Mean cath LV mass was 207.8 +- 45.4g (S.D.). Mean SPECT LV mass was 207.4 +- 43.3 g. Linear regression analysis revealed the following relationship: SPECT LV mass = 0.78 x Cath LV mass +45.8 (r=0.82, root mean square deviation from regression = 25.1). The SPECT values of LV mass varied an average of 10.4+- 4.6 (S.D.) % in the 5 patients where two determinations were made. The authors conclude that SPECT of T1-201 can accurately measure left ventricular mass in man.

  10. [Analysis of single-photon emission computed tomography in patients with hypertensive encephalopathy complicated with previous hypertensive crisis].

    Science.gov (United States)

    Kustkova, H S

    2012-01-01

    In cerebrovascular diseases pefuzionnaya single photon emission computed tomography with lipophilic amines used for the diagnosis of functional disorders of cerebral blood flow. Quantitative calculations helps clarify the nature of vascular disease and clarify the adequacy and effectiveness of the treatment. In this modern program for SPECT ensure conduct not only as to the calculation of blood flow, but also make it possible to compute also the absolute values of cerebral blood flow.

  11. Single photon infrared emission spectroscopy: a study of IR emission from UV laser excited PAHs between 3 and 15 micrometers

    Science.gov (United States)

    Cook, D. J.; Schlemmer, S.; Balucani, N.; Wagner, D. R.; Harrison, J. A.; Steiner, B.; Saykally, R. J.

    1998-01-01

    Single-photon infrared emission spectroscopy (SPIRES) has been used to measure emission spectra from polycyclic aromatic hydrocarbons (PAHs). A supersonic free-jet expansion has been used to provide emission spectra of rotationally cold and vibrationally excited naphthalene and benzene. Under these conditions, the observed width of the 3.3-micrometers (C-H stretch) band resembles the bandwidths observed in experiments in which emission is observed from naphthalene with higher rotational energy. To obtain complete coverage of IR wavelengths relevant to the unidentified infrared bands (UIRs), UV laser-induced desorption was used to generate gas-phase highly excited PAHs. Lorentzian band shapes were convoluted with the monochromator-slit function in order to determine the widths of PAH emission bands under astrophysically relevant conditions. Bandwidths were also extracted from bands consisting of multiple normal modes blended together. These parameters are grouped according to the functional groups mostly involved in the vibration, and mean bandwidths are obtained. These bandwidths are larger than the widths of the corresponding UIR bands. However, when the comparison is limited to the largest PAHs studied, the bandwidths are slightly smaller than the corresponding UIR bands. These parameters can be used to model emission spectra from PAH cations and cations of larger PAHs, which are better candidate carriers of the UIRs.

  12. Pulmonary Arterial Hypertension With Abnormal V/Q Single-Photon Emission Computed Tomography.

    Science.gov (United States)

    Chan, Kenneth; Ioannidis, Stefanos; Coghlan, John G; Hall, Margaret; Schreiber, Benjamin E

    2017-10-16

    This study aimed to evaluate the incidence and clinical outcomes of abnormal ventilation/perfusion (V/Q) single-photon emission computed tomography (SPECT) without thromboembolism, especially in patients with group I pulmonary arterial hypertension (PAH). American Heart Association/American College of Cardiology and European Society of Cardiology guidelines recommend V/Q scan for screening for chronic thromboembolic pulmonary hypertension. The significance of patients with abnormal V/Q SPECT findings but no thromboembolism demonstrated in further investigations remained unclear. A distinct pattern of global patchy changes not typical of thromboembolism is recognized, but guidelines for reporting these in the context of PAH are lacking. A total of 136 patients who underwent V/Q SPECT and right-sided heart catheterization showing mean pulmonary arterial pressure ≥25 mm Hg were included. V/Q SPECT findings were reported using European Association of Nuclear Medicine criteria for pulmonary embolism followed by computed tomography pulmonary angiography screening for positive thromboembolism and further invasive pulmonary angiography for distal thromboembolism. The abnormal V/Q SPECT images were further analyzed according to perfusion pattern into focal or global perfusion defects. V/Q SPECT showed thromboembolic disease in 44 patients, but 19 of these patients had no thromboembolism demonstrated by pulmonary angiography. Among these patients, 15 of 19 (78.9%) had group I PAH, and the majority had diffuse, patchy perfusion defects. After redefining V/Q SPECT images according to the perfusion pattern, those patients with global perfusion defects had higher mean pulmonary arterial pressure compared with patients with focal perfusion defects and normal scans (mean difference +13.9 and +6.2 mm Hg, respectively; p = 0.0002), as well as higher pulmonary vascular resistance (mean difference +316.6 and +226.3 absolute resistance units, respectively; p = 0

  13. Coherent properties of single quantum dot transitions and single photon emission

    Energy Technology Data Exchange (ETDEWEB)

    Ester, Patrick

    2008-04-23

    of the first laser pulse. The relative phase of the QDs exciton can be controlled externally via the bias voltage. This effect is the basis for the observation of RAMSEY-fringes, which are presented in this work. The coherent manipulation of the p-shell is the basis for a novel excitation scheme for single photon emission. In this work it is shown that the first excited state can be coherently manipulated, similar to the ground state. (orig.)

  14. Cerebral Hypoperfusion in Hereditary Coproporphyria (HCP): A Single Photon Emission Computed Tomography (SPECT) Study

    Science.gov (United States)

    Valle, Guido; Guida, Claudio Carmine; Nasuto, Michelangelo; Totaro, Manuela; Aucella, Filippo; Frusciante, Vincenzo; Di Mauro, Lazzaro; Potenza, Adele; Savino, Maria; Stanislao, Mario; Popolizio, Teresa; Guglielmi, Giuseppe; Giagulli, Vito Angelo; Guastamacchia, Edoardo; Triggiani, Vincenzo

    2016-01-01

    Background: Hereditary Coproporphyria (HCP) is characterized by abdominal pain, neurologic symptoms and psychiatric disorders, even if it might remain asymptomatic. The pathophysiology of both neurologic and psychiatric symptoms is not fully understood. Therefore, aiming to evaluate a possible role of brain blood flow disorders, we have retrospectively investigated cerebral perfusion patterns in Single Photon Emission Computed Tomography (SPECT) studies in HCP patients. Materials & Methods: We retrospectively evaluated the medical records of patients diagnosed as being affected by HCP. A total of seven HCP patients had been submitted to brain perfusion SPECT study with 99mTc-Exametazime (hexamethylpropyleneamine oxime, HMPAO) or with its functionally equivalent 99mTc-Bicisate (ECD or Neurolite) according with common procedures. In 3 patients the scintigraphic study had been repeated for a second time after the first evaluation at 3, 10 and 20 months, respectively. All the studied subjects had been also submitted to an electromyographic and a Magnetic Resonance Imaging (MRI) study of the brain. Results: Mild to moderate perfusion defects were detected in temporal lobes (all 7 patients), frontal lobes (6 patients) and parietal lobes (4 patients). Occipital lobe, basal ganglia and cerebellar involvement were never observed. In the three subjects in which SPECT study was repeated, some recovery of hypo-perfused areas and appearance of new perfusion defects in other brain regions have been found. In all patients electromyography resulted normal and MRI detected few unspecific gliotic lesions only in one patient. Discussion & Conclusions: Since perfusion abnormalities were usually mild to moderate, this can probably explain the normal pattern observed at MRI studies. Compared to MRI, SPECT with 99mTc showed higher sensitivity in HCP patients. Changes observed in HCP patients who had more than one study suggest that transient perfusion defects might be due to a brain

  15. Brain Perfusion Single Photon Emission Computed Tomography Abnormalities in Patients with Minimal Hepatic Encephalopathy

    Science.gov (United States)

    Sunil, Hejjaji Venkataramarao; Mittal, Bhagwant Rai; Kurmi, Roshan; Chawla, Yogesh K; Dhiman, Radha K

    2012-01-01

    Background Minimal hepatic encephalopathy (MHE) is the mildest form of hepatic encephalopathy (HE). Minimal hepatic encephalopathy patients do not demonstrate clinically overt symptoms of HE but present with abnormal neuropsychological and/or neurophysiological tests indicative of cerebral dysfunction. This study was performed in such patients to identify regions of abnormal cerebral perfusion and to correlate regional cerebral blood flow (rCBF) changes with psychometric hepatic encephalopathy score (PHES), Child-Turcotte-Pugh's score (CTP), and model for end-stage liver disease (MELD) score. We also compared abnormal patterns of rCBF in cirrhotic patients of alcoholic etiology with non-alcoholic etiology. Methods This prospective study was performed to evaluate rCBF in 50 cirrhotic patients and 13 controls using technetium-99m ethyl cysteinate dimer (Tc-99m ECD) brain single photon emission computed tomography. All the patients underwent a battery of psychometry tests, PHES. Minimal hepatic encephalopathy was diagnosed if PHES was ≤−5. The rCBF changes were evaluated using region of interest (ROI) based semi-quantitative method of region/cerebellum and region/cortex ratios in 16 regions of the brain. Results Cirrhotic patients with MHE showed impaired perfusion in the superior prefrontal cortex and increased perfusion in the thalamus, brain-stem, medial temporal cortex, and the hippocampus when compared with the controls. Cerebral perfusion in superior prefrontal cortex correlated negatively with MELD score (r=−0.323, P=0.022). We found significant positive correlation between PHES score and rCBF values in the left superior prefrontal cortex (r=0.385, P=0.006). Cirrhotic patients with alcohol etiology showed significantly decreased rCBF in right inferior prefrontal cortex, right superior prefrontal cortex, and the anterior cingulate cortex while increased rCBF was noted in the right medial temporal cortex and hippocampus. Conclusion Our results suggest that

  16. Single-photon emission from InAsP quantum dots embedded in density-controlled InP nanowires

    Science.gov (United States)

    Yanase, Shougo; Sasakura, Hirotaka; Hara, Shinjiro; Motohisa, Junichi

    2017-04-01

    We attempted to control the density and size of InP-based nanowires (NWs) and nanowire quantum dots (NW-QDs) during selective-area metalorganic vapor phase epitaxy. InP nanowire arrays with a 5 µm pitch and an average NW diameter d of 67 nm were successfully grown by optimization of growth conditions. InAsP quantum dots were embedded in these density-controlled InP NW arrays, and clear single-photon emission and exciton-biexciton cascaded emission were confirmed by excitation-dependent photoluminescence and photon correlation measurements.

  17. Evaluation of myocardial abnormalities in collagen diseases by thallium-201 myocardial scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Yamano, Shigeru; Kagoshima, Tadashi; Sugihara, Kiyotaka (Nara Medical Univ., Kashihara (Japan)) (and others)

    1993-12-01

    This study was performed to evaluate myocardial abnormalities in patients with collagen diseases by exercise and rest thallium-201 myocardial scintigrams. A total of 65 patients without ischemic ECG changes, consisting of 18 with systemic lupus erythematosus (SLE), 18 with polymyositis (PM), 8 with progressive systemic sclerosis (PSS), and 21 with Sjoegren's syndrome (SjS), was enrolled in this study. Reversible exercise-induced defects scintigraphically suggesting myocardial ischemia were noted in 8 cases of SLE, 4 cases of PM, 4 cases of PSS, and 3 cases of SjS. Nineteen patients had exercise-induced defects and underwent cardiac catheterization, 8 of whom had normal coronary angiograms. Fixed hypoperfusion areas were observed in one case of SLE, 6 cases of PM and 3 cases of SjS. Rest thallium-201 myocardial scintigram disclosed hypoperfusion areas which were not induced by exercise in 2 cases of SLE, 3 cases of PM, one case of PSS and 5 cases of SjS. Echocardiogram showed no significant differences in ejection fraction and % fractional shortening between the disease groups and healthy control group. These findings suggest that patients with collagen diseases have abnormalities of coronary circulation at the level of the intramural vasculature before cardiac function impairment, myocardial fibrosis and functional abnormalities at the cell membrane. (author).

  18. Qualitative evaluation of coronary flow during anesthetic induction using thallium-201 perfusion scans

    Energy Technology Data Exchange (ETDEWEB)

    Kleinman, B.; Henkin, R.E.; Glisson, S.N.; el-Etr, A.A.; Bakhos, M.; Sullivan, H.J.; Montoya, A.; Pifarre, R.

    1986-02-01

    Qualitative distribution of coronary flow using thallium-201 perfusion scans immediately postintubation was studied in 22 patients scheduled for elective coronary artery bypass surgery. Ten patients received a thiopental (4 mg/kg) and halothane induction. Twelve patients received a fentanyl (100 micrograms/kg) induction. Baseline thallium-201 perfusion scans were performed 24 h prior to surgery. These scans were compared with the scans performed postintubation. A thallium-positive scan was accepted as evidence of relative hypoperfusion. Baseline hemodynamic and ECG data were obtained prior to induction of anesthesia. These data were compared with the data obtained postintubation. Ten patients developed postintubation thallium-perfusion scan defects (thallium-positive scan), even though there was no statistical difference between their baseline hemodynamics and hemodynamics at the time of intubation. There was no difference in the incidence of thallium-positive scans between those patients anesthetized by fentanyl and those patients anesthetized with thiopental-halothane. The authors conclude that relative hypoperfusion, and possibly ischemia, occurred in 45% of patients studied, despite stable hemodynamics, and that the incidence of these events was the same with two different anesthetic techniques.

  19. Bright Room-Temperature Single Photon Emission from Defects in Gallium Nitride

    CERN Document Server

    Berhane, Amanuel M; Bodrog, Zoltán; Fiedler, Saskia; Schröder, Tim; Triviño, Noelia Vico; Palacios, Tomás; Gali, Adam; Toth, Milos; Englund, Dirk; Aharonovich, Igor

    2016-01-01

    Single photon emitters play a central role in many photonic quantum technologies. A promising class of single photon emitters consists of atomic color centers in wide-bandgap crystals, such as diamond silicon carbide and hexagonal boron nitride. However, it is currently not possible to grow these materials as sub-micron thick films on low-refractive index substrates, which is necessary for mature photonic integrated circuit technologies. Hence, there is great interest in identifying quantum emitters in technologically mature semiconductors that are compatible with suitable heteroepitaxies. Here, we demonstrate robust single photon emitters based on defects in gallium nitride (GaN), the most established and well understood semiconductor that can emit light over the entire visible spectrum. We show that the emitters have excellent photophysical properties including a brightness in excess of 500x10^3 counts/s. We further show that the emitters can be found in a variety of GaN wafers, thus offering reliable and s...

  20. Nearly Blinking-Free, High-Purity Single-Photon Emission by Colloidal InP/ZnSe Quantum Dots.

    Science.gov (United States)

    Chandrasekaran, Vigneshwaran; Tessier, Mickaël D; Dupont, Dorian; Geiregat, Pieter; Hens, Zeger; Brainis, Edouard

    2017-10-11

    Colloidal core/shell InP/ZnSe quantum dots (QDs), recently produced using an improved synthesis method, have a great potential in life-science applications as well as in integrated quantum photonics and quantum information processing as single-photon emitters. Single-particle spectroscopy of 10 nm QDs with 3.2 nm cores reveals strong photon antibunching attributed to fast (70 ps) Auger recombination of multiple excitons. The QDs exhibit very good photostability under strong optical excitation. We demonstrate that the antibunching is preserved when the QDs are excited above the saturation intensity of the fundamental-exciton transition. This result paves the way toward their usage as high-purity on-demand single-photon emitters at room temperature. Unconventionally, despite the strong Auger blockade mechanism, InP/ZnSe QDs also display very little luminescence intermittency ("blinking"), with a simple on/off blinking pattern. The analysis of single-particle luminescence statistics places these InP/ZnSe QDs in the class of nearly blinking-free QDs, with emission stability comparable to state-of-the-art thick-shell and alloyed-interface CdSe/CdS, but with improved single-photon purity.

  1. Nearly Blinking-Free, High-Purity Single-Photon Emission by Colloidal InP/ZnSe Quantum Dots

    Science.gov (United States)

    Chandrasekaran, Vigneshwaran; Tessier, Mickaël D.; Dupont, Dorian; Geiregat, Pieter; Hens, Zeger; Brainis, Edouard

    2017-10-01

    Colloidal core/shell InP/ZnSe quantum dots (QDs), recently produced using an improved synthesis method, have a great potential in life-science applications as well as in integrated quantum photonics and quantum information processing as single-photon emitters. Single-particle spectroscopy of 10-nm QDs with 3.2-nm cores reveals strong photon antibunching attributed to fast (70-ps) Auger recombination of multiple excitons. The QDs exhibit very good photostability under strong optical excitation. We demonstrate that the antibunching is preserved when the QDs are excited above the saturation intensity of the fundamental-exciton transition. This result paves the way towards their usage as high-purity on-demand single-photon emitters at room temperature. Unconventionally, despite the strong Auger blockade mechanism, InP/ZnSe QDs also display very little luminescence intermittency ("blinking"), with a simple on/off blinking pattern. The analysis of single-particle luminescence statistics places these InP/ZnSe QDs in the class of nearly blinking-free QDs, with emission stability comparable to state-of-the-art thick-shell and alloyed-interface CdSe/CdS, but with improved single-photon purity.

  2. Single photon emission and quantum ring-cavity coupling in InAs/GaAs quantum rings

    Energy Technology Data Exchange (ETDEWEB)

    Gallardo, E; Nowak, A K; Sanvitto, D; Meulen, H P van der; Calleja, J M [Departamento de Fisica de Materiales, Universidad Autonoma de Madrid, E-28049 Madrid (Spain); MartInez, L J; Prieto, I; Alija, A R; Granados, D; Taboada, A G; GarcIa, J M; Postigo, P A [Instituto de Microelectronica de Madrid, Centro Nacional de MicrotecnologIa, CSIC, Isaac Newton 8, PTM Tres Cantos, E-28760 Madrid (Spain); Sarkar, D, E-mail: eva.gallardo@uam.e [Department of Physics and Astronomy, University of Sheffield, S3 7RH (United Kingdom)

    2010-02-01

    Different InAs/GaAs quantum rings embedded in a photonic crystal microcavity are studied by quantum correlation measurements. Single photon emission, with g{sup (2)}(0) values around 0.3, is demonstrated for a quantum ring not coupled to the microcavity. Characteristic rise-times are found to be longer for excitons than for biexcitons, resulting in the time asymmetry of the exciton-biexciton cross-correlation. No antibunching is observed in another quantum ring weakly coupled to the microcavity.

  3. Single-photon emission from electrically driven InP quantum dots epitaxially grown on CMOS-compatible Si(001).

    Science.gov (United States)

    Wiesner, M; Schulz, W-M; Kessler, C; Reischle, M; Metzner, S; Bertram, F; Christen, J; Roßbach, R; Jetter, M; Michler, P

    2012-08-24

    The heteroepitaxy of III-V semiconductors on silicon is a promising approach for making silicon a photonic platform. Mismatches in material properties, however, present a major challenge, leading to high defect densities in the epitaxial layers and adversely affecting radiative recombination processes. However, nanostructures, such as quantum dots, have been found to grow defect-free even in a suboptimal environment. Here we present the first realization of indium phosphide quantum dots on exactly oriented Si(001), grown by metal-organic vapour-phase epitaxy. We report electrically driven single-photon emission in the red spectral region, meeting the wavelength range of silicon avalanche photodiodes' highest detection efficiency.

  4. Effect of expression of P-glycoprotein on technetium-99m methoxyisobutylisonitrile single photon emission computed tomography of brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Shibata, Yasushi; Matsumura, Akira; Nose, Tadao [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine

    2002-08-01

    The expression of P-glycoprotein was investigated imunohistochemically in 26 brain tumor tissues and compared with the findings of technetium-99m methoxyisobutylisonitrile single photon emission computed tomography ({sup 99m}Tc-MIBI SPECT) to clarify the effect of P-glycoprotein on the diagnostic accuracy. P-glycoprotein labeling index of both tumor cells and vascular endothelial cells showed no clear relationship with the findings of {sup 99m}Tc-MIBI SPECT imaging. Expression of P-glycoprotein has no effect on the diagnostic accuracy of {sup 99m}Tc-MIBI SPECT. (author)

  5. Single Cesium Lead Halide Perovskite Nanocrystals at Low Temperature: Fast Single-Photon Emission, Reduced Blinking, and Exciton Fine Structure.

    Science.gov (United States)

    Rainò, Gabriele; Nedelcu, Georgian; Protesescu, Loredana; Bodnarchuk, Maryna I; Kovalenko, Maksym V; Mahrt, Rainer F; Stöferle, Thilo

    2016-02-23

    Metal-halide semiconductors with perovskite crystal structure are attractive due to their facile solution processability, and have recently been harnessed very successfully for high-efficiency photovoltaics and bright light sources. Here, we show that at low temperature single colloidal cesium lead halide (CsPbX3, where X = Cl/Br) nanocrystals exhibit stable, narrow-band emission with suppressed blinking and small spectral diffusion. Photon antibunching demonstrates unambiguously nonclassical single-photon emission with radiative decay on the order of 250 ps, representing a significant acceleration compared to other common quantum emitters. High-resolution spectroscopy provides insight into the complex nature of the emission process such as the fine structure and charged exciton dynamics.

  6. Evaluation of myocardial abnormalities in patients with collagen diseases by thallium-201 myocardial scintigram

    Energy Technology Data Exchange (ETDEWEB)

    Yamano, Shigeru (Nara Medical Univ., Kashihara (Japan))

    1992-08-01

    This study was performed to evaluate myocardial lesions in patients with collagen diseases by rest and exercise thallium-201 myocardial scintigraphies. A total of 76 patients without ischemic ECG changes, consisting of 27 cases of systemic lupus erythematosus (SLE), 17 cases of polymyositis or dermatomyositis (PM[center dot]DM), 11 cases of progressive systemic sclerosis (PSS), and 21 cases of Sjoegren's syndrome (SjS), were enrolled in this study. Reversible exercise-induced defects suggesting myocardial ischemia were noted in 12 cases of SLE, 5 cases of PM[center dot]DM, 3 cases of PSS, and 3 cases of SjS. Of the 23 patients who had exercise-induced defects, 9 patients showed normal coronary angiograms by cardiac catheterization. Fixed hypoperfusion areas were observed in 5 cases of SLE, 6 cases of PM[center dot]DM, 4 cases of PSS and 3 cases of SjS. Rest thallium-201 myocardial scintigraphy disclosed hypoperfusion areas, which were not induced by exercise, in 1 case of SLE, 4 cases of PM[center dot]DM, 1 case of PSS and 5 cases of SjS. Endomyocardial biopsy was performed on 20 patients. Myocardial lesions in PM[center dot]DM and PSS were more severe and wide spread than in SLE. Ejection fraction and fractional shortening evaluated by echocardiography had no significant differences between each disease group and the healthy control group. These findings suggest that patients with collagen diseases show the presence of abnormalities of coronary circulation at the level of the intramyocardial vasculature in the stage before impairment of cardiac function, myocardial fibrosis and functional abnormalities of the cell membrane level that were not dependent on myocardial ischemia. (author).

  7. 3-D maximum a posteriori estimation for single photon emission computed tomography on massively-parallel computers.

    Science.gov (United States)

    Miller, M I; Butler, C S

    1993-01-01

    A fully three-dimensional (3-D) implementation of the maximum a posteriori (MAP) method for single photon emission computed tomography (SPECT) is demonstrated. The 3-D reconstruction exhibits a major increase in resolution when compared to the generation of the series of separate 2-D slice reconstructions. As has been noted, the iterative EM algorithm for 2-D reconstruction is highly computational; the 3-D algorithm is far worse. To accommodate the computational complexity, previous work in the 2-D arena is extended, and an implementation on the class of massively parallel processors of the 3-D algorithm is demonstrated. Using a 16000- (4000-) processor MasPar/DECmpp-Sx machine, the algorithm is demonstrated to execute at 2.5 (7.8) s/EM-iteration for the entire 64x64x64 cube of 96 planar measurements obtained from the Siemens Orbiter rotating camera operating in the high-resolution mode.

  8. Development and application of an automated analysis method for individual cerebral perfusion single photon emission tomography images

    CERN Document Server

    Cluckie, A J

    2001-01-01

    Neurological images may be analysed by performing voxel by voxel comparisons with a group of control subject images. An automated, 3D, voxel-based method has been developed for the analysis of individual single photon emission tomography (SPET) scans. Clusters of voxels are identified that represent regions of abnormal radiopharmaceutical uptake. Morphological operators are applied to reduce noise in the clusters, then quantitative estimates of the size and degree of the radiopharmaceutical uptake abnormalities are derived. Statistical inference has been performed using a Monte Carlo method that has not previously been applied to SPET scans, or for the analysis of individual images. This has been validated for group comparisons of SPET scans and for the analysis of an individual image using comparison with a group. Accurate statistical inference was obtained independent of experimental factors such as degrees of freedom, image smoothing and voxel significance level threshold. The analysis method has been eval...

  9. Single photon emission computed tomography using sup 99 Tc sup m -HMPAO in Alzheimer's disease

    Energy Technology Data Exchange (ETDEWEB)

    Liu, H.-C.; Liu, R.-S.; Lin, K.-N.; Wang, S.-J.; Fuh, J.-L.; Yeh, S.-H.; Chiang, B.N. (Veterans General Hospital, Taipei, Taiwan (China))

    1992-07-01

    Brain single photon emission computed tomography (SPET) using {sup 99m}Tc{sup m}-hexamethylpropyleneamine oxime (HMPAO) was performed in 37 patients satisfying standard clinical criteria of Alzheimer's disease (AD), correlating results with patient's age of onset, duration of illness, severity of dementia, neuropsychological impairment, computed tomography (CT) and EEG findings. All had abnormal SPET: 23 were bilaterally symmetric, 10 bilaterally asymmetric and four showed unilateral low regional cerebral perfusion. Low perfusion in bilateral parietal regions was the most consistent finding and was present alone or with other abnormal regions in 31 patients (84%). The only significant clinical correlation was found between asymmetric SPECT changes and onset of disease before the age of 65 years. 50% of patients with presenile onset, but only 19% with senile onset had asymmetric low regional cerebral perfusion. Fifteen of the 36 patients had normal brain CT scans, and 9 of 31 patients receiving EEG examination had normal results. (author).

  10. Interictal "patchy" regional cerebral blood flow patterns in migraine patients. A single photon emission computerized tomographic study

    DEFF Research Database (Denmark)

    Friberg, L; Olesen, J; Iversen, Helle Klingenberg

    1994-01-01

    In 92 migraine patients and 44 healthy control subjects we recorded regional cerebral blood flow (rCBF) with single photon emission computerized tomography and (133) Xe inhalation or with i.v. (99m) Tc-HMPAO. Migraine patients were studied interictally. A quantitated analysis of right.......28). There was no correlation between visual or quantitated abnormalities and age, duration of migraine, frequency of attacks or prophylactic medication. No correlation could be established between asymmetries and the usual side of headache or aura symptoms. Two conclusions emerged: (1) visual evaluation of interictal migraine...... rCBF images is insufficient to pick up abnormalities; (2) almost 50% of the migraine sufferers had abnormal rCBF/asymmetries. However, these are discrete compared with those typically seen during the aura phase of a migraine attack. One explanation to the patchy rCBF patterns might...

  11. Left leg apraxia after anterior cerebral artery territory infarction: functional analysis using single-photon emission computed tomography.

    Science.gov (United States)

    Ito, Ikuno; Ito, Kimiteru; Shindo, Naoko

    2013-01-01

    Left hand apraxia is known as a unique symptom of callosal apraxia, but lower limb symptoms are rarely mentioned. We report a patient who experienced left ideomotor apraxia affecting both the upper and lower limbs after a stroke in the territory of the right anterior cerebral artery. His spontaneous gait was normal, but he was unable to move his left leg intentionally either by verbal command or by imitation. His leg symptoms gradually improved over time. We evaluated the change in cerebral blood flow in this patient using single-photon emission computed tomography. The results showed an increase in blood flow in the posterior corpus callosum; therefore, we suggested that the callosal pathway might contribute to left leg as well as left hand volitional movement. Copyright © 2013 S. Karger AG, Basel.

  12. Increased single-photon emission computed tomography image processing speed achieved in personal computers with memory-intensive algorithms.

    Science.gov (United States)

    Pratt, J P; Lear, J L

    1993-11-01

    Recent dramatic reductions in the cost of computer random access memory (RAM) and the ability of newer microprocessors and associated personal computer operating systems to address large amounts of memory make novel strategies for high-speed image processing possible. We developed image processing algorithms that use this newly available memory to achieve increases in effective processing speed. These algorithms rely on the use of precomputed lookup tables to avoid repeated use of relatively expensive machine instructions, such as multiplications and divisions. Programs using this strategy to perform single photon emission computer tomography (SPECT) analysis were written in C and assembly language and tested on a Macintosh Quadra 950 (Apple Computer, Cupertino, CA) having 64 megabytes of RAM. The measured processing times are competitive with most dedicated nuclear medicine computers. A general implementation of such programs will allow personal computers to compete with dedicated imaging systems, at a substantial reduction in cost.

  13. Septal myocardial perfusion imaging with thallium-201 in the diagnosis of proximal left anterior descending coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Pichard, A.D.; Wiener, I.; Martinez, E.; Horowitz, S.; Patterson, R.; Meller, J.; Goldsmith, S.J.; Gorlin, R.; Herman, M.V.

    1981-07-01

    The use of myocardial perfusion imaging (MPI) to identify obstructive coronary disease of the left anterior descending coronary artery proximal to the first septal perforator (prox LAD) was studied in 60 patients. Perfusion of the septum and anteroapical areas with thallium-201 injected during exercise was compared to results of coronary arteriography. Septal MPI defect was found in 92.3% of patients with obstruction of the proximal LAD, 27.7% of patients with obstruction of LAD distal to first septal perforator, 0% in patients with obstructions involving right or circumflex arteries, and in 10.5% of patients without coronary disease. Anteroapical MPI defects were found with similar frequency in the three groups with obstructive coronary disease. Septal MPI defect had a sensitivity of 92.3% and specificity of 85.4% in the diagnosis of proximal LAD disease. Normal septal perfusion with thallium-201 virtually excluded proximal LAD disease.

  14. Performance assessment of the single photon emission microscope: high spatial resolution SPECT imaging of small animal organs

    Energy Technology Data Exchange (ETDEWEB)

    Mejia, J. [Hospital Israelita Albert Einstein, Instituto do Cérebro, São Paulo, SP (Brazil); Reis, M.A. [Hospital Israelita Albert Einstein, Instituto do Cérebro, São Paulo, SP (Brazil); Laboratório Interdisciplinar de Neurociências Clínicas, Departamento de Psiquiatria, Universidade Federal de São Paulo, São Paulo, SP (Brazil); Miranda, A.C.C. [Hospital Israelita Albert Einstein, Instituto do Cérebro, São Paulo, SP (Brazil); Batista, I.R. [Hospital Israelita Albert Einstein, Instituto do Cérebro, São Paulo, SP (Brazil); Laboratório Interdisciplinar de Neurociências Clínicas, Departamento de Psiquiatria, Universidade Federal de São Paulo, São Paulo, SP (Brazil); Barboza, M.R.F.; Shih, M.C. [Hospital Israelita Albert Einstein, Instituto do Cérebro, São Paulo, SP (Brazil); Fu, G. [GE Global Research, Schenectady, NY (United States); Chen, C.T. [Department of Radiology, University of Chicago, Chicago, IL (United States); Meng, L.J. [Department of Nuclear, Plasma and Radiological Engineering, University of Illinois, Urbana-Champaign, IL (United States); Bressan, R.A. [Hospital Israelita Albert Einstein, Instituto do Cérebro, São Paulo, SP (Brazil); Laboratório Interdisciplinar de Neurociências Clínicas, Departamento de Psiquiatria, Universidade Federal de São Paulo, São Paulo, SP (Brazil); Amaro, E. Jr [Hospital Israelita Albert Einstein, Instituto do Cérebro, São Paulo, SP (Brazil)

    2013-11-06

    The single photon emission microscope (SPEM) is an instrument developed to obtain high spatial resolution single photon emission computed tomography (SPECT) images of small structures inside the mouse brain. SPEM consists of two independent imaging devices, which combine a multipinhole collimator, a high-resolution, thallium-doped cesium iodide [CsI(Tl)] columnar scintillator, a demagnifying/intensifier tube, and an electron-multiplying charge-coupling device (CCD). Collimators have 300- and 450-µm diameter pinholes on tungsten slabs, in hexagonal arrays of 19 and 7 holes. Projection data are acquired in a photon-counting strategy, where CCD frames are stored at 50 frames per second, with a radius of rotation of 35 mm and magnification factor of one. The image reconstruction software tool is based on the maximum likelihood algorithm. Our aim was to evaluate the spatial resolution and sensitivity attainable with the seven-pinhole imaging device, together with the linearity for quantification on the tomographic images, and to test the instrument in obtaining tomographic images of different mouse organs. A spatial resolution better than 500 µm and a sensitivity of 21.6 counts·s{sup -1}·MBq{sup -1} were reached, as well as a correlation coefficient between activity and intensity better than 0.99, when imaging {sup 99m}Tc sources. Images of the thyroid, heart, lungs, and bones of mice were registered using {sup 99m}Tc-labeled radiopharmaceuticals in times appropriate for routine preclinical experimentation of <1 h per projection data set. Detailed experimental protocols and images of the aforementioned organs are shown. We plan to extend the instrument's field of view to fix larger animals and to combine data from both detectors to reduce the acquisition time or applied activity.

  15. Performance assessment of the single photon emission microscope: high spatial resolution SPECT imaging of small animal organs

    Directory of Open Access Journals (Sweden)

    J. Mejia

    2013-11-01

    Full Text Available The single photon emission microscope (SPEM is an instrument developed to obtain high spatial resolution single photon emission computed tomography (SPECT images of small structures inside the mouse brain. SPEM consists of two independent imaging devices, which combine a multipinhole collimator, a high-resolution, thallium-doped cesium iodide [CsI(Tl] columnar scintillator, a demagnifying/intensifier tube, and an electron-multiplying charge-coupling device (CCD. Collimators have 300- and 450-µm diameter pinholes on tungsten slabs, in hexagonal arrays of 19 and 7 holes. Projection data are acquired in a photon-counting strategy, where CCD frames are stored at 50 frames per second, with a radius of rotation of 35 mm and magnification factor of one. The image reconstruction software tool is based on the maximum likelihood algorithm. Our aim was to evaluate the spatial resolution and sensitivity attainable with the seven-pinhole imaging device, together with the linearity for quantification on the tomographic images, and to test the instrument in obtaining tomographic images of different mouse organs. A spatial resolution better than 500 µm and a sensitivity of 21.6 counts·s-1·MBq-1 were reached, as well as a correlation coefficient between activity and intensity better than 0.99, when imaging 99mTc sources. Images of the thyroid, heart, lungs, and bones of mice were registered using 99mTc-labeled radiopharmaceuticals in times appropriate for routine preclinical experimentation of <1 h per projection data set. Detailed experimental protocols and images of the aforementioned organs are shown. We plan to extend the instrument's field of view to fix larger animals and to combine data from both detectors to reduce the acquisition time or applied activity.

  16. Single photon source characterization with a superconducting single photon detector.

    Science.gov (United States)

    Hadfield, Robert H; Stevens, Martin J; Gruber, Steven S; Miller, Aaron J; Schwall, Robert E; Mirin, Richard P; Nam, Sae Woo

    2005-12-26

    Superconducting single photon detectors (SSPD) based on nanopatterned niobium nitride wires offer single photon counting at fast rates, low jitter, and low dark counts, from visible wavelengths well into the infrared. We demonstrate the first use of an SSPD, packaged in a commercial cryocooler, for single photon source characterization. The source is an optically pumped, microcavity-coupled InGaAs quantum dot, emitting single photons at 902 nm. The SSPD replaces the second silicon Avalanche Photodiode (APD) in a Hanbury-Brown Twiss interferometer measurement of the source second-order correlation function, g(2)( ?). The detection efficiency of the superconducting detector system is >2 % (coupling losses included). The SSPD system electronics jitter is 170 ps, versus 550 ps for the APD unit, allowing the source spontaneous emission lifetime to be measured with improved resolution.

  17. Thallium-201 SPECT in the diagnosis of head and neck cancer.

    Science.gov (United States)

    Valdés Olmos, R A; Balm, A J; Hilgers, F J; Koops, W; Loftus, B M; Tan, I B; Muller, S H; Hoefnagel, C A; Gregor, R T

    1997-06-01

    The accuracy of SPECT with 201Tl-chloride for the diagnosis of primary tumors, lymph node metastases and recurrences in head and neck cancer was evaluated for clinical applicability. SPECT images, obtained 60 min after administration of 150 MBq 201Tl-chloride, were compared with clinical, CT and/or MRI and histology results. In addition, whole-body images were obtained to detect distant metastases. In 79 patients studied for primary tumors (principally larynix, hypopharynx, oropharynx, nasopharynx and oral cavity), 201Tl SPECT correctly identified 69 of 73 (95% versus 88% for CT/MRI) histologically confirmed malignancies including 63 squamous-cell carcinomas. The method localized four occult naso- and oropharynx carcinomas not seen on CT/MRI and was correctly negative in two patients without tumor and in three of four patients with no confirmed primary tumor in the head and neck. With respect to regional spread, only patients who had cervical lymph node dissection were evaluated, and the findings were recorded per side of the neck. Thallium-201 SPECT correctly identified metastases in 31 of 36 neck dissections with proven lymph node involvement (86%), was correctly negative in nine and false-positive in one. Although the sensitivity of CT/MRI was clearly higher (97%), considerably more false-positive cases affected its accuracy (81% versus 87% for SPECT). In 30 patients investigated for recurrences, 201Tl SPECT correctly identified 27 of 29 microscopically confirmed tumor sites (93%) and was correctly negative in seven. Sensitivity of CT/MRI was lower (76%), and a greater number of false-positives (seven versus three for SPECT) further decreased its accuracy (64% versus 87% for SPECT). Distant metastases were detected in five patients. Thallium-201 SPECT appears to be an accurate method for the diagnosis of head and neck cancer. The method is particularly useful for detection of occult head and neck tumors and for assessing recurrences. It also may be of

  18. Preliminary experience with thallous chloride T1 201-labeled single-photon emission computed tomography scanning in head and neck cancer

    NARCIS (Netherlands)

    Gregor, R. T.; Valdés-Olmos, R.; Koops, W.; Balm, A. J.; Hilgers, F. J.; Hoefnagel, C. A.

    1996-01-01

    To test the feasibility of single-photon emission computed tomography (SPECT) scanning with the use of thallous chloride T1 201 in patients with head and neck cancer and to decide its possible applications to improve the diagnosis and staging of head and neck cancer. Findings from SPECT with the use

  19. Synthesis of (R,R) sup 123 I-QNB, a SPECT (single photon emission computed tomography) imaging agent for cerebral muscarinic acetylcholine receptors in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Owens, J.; McCulloch, J. (Glasgow Univ. (United Kingdom)); Murray, T. (Glasgow Western Infirmary (United Kingdom)); Wyper, D. (Southern General Hospital, Glasgow (United Kingdom). Inst. of Neurological Sciences)

    1992-01-01

    The high-affinity muscarinic receptor antagonist (R,R) I-QNB ((R)-(-)-1-Azabicyclo(2.2.2)oct-3-yl-(R)-(+)-{alpha}-hydroxy-{alpha}-(4-( {sup 127}I)iodophenyl)-{alpha}-phenyl Acetate) has been labeled with iodine-123 to give a suitable ligand for SPECT (Single photon emission computed tomography) imaging of the human brain. (author).

  20. Demonstration of a reduction in muscarinic receptor binding in early Alzheimer's disease using iodine-123 dexetimide single-photon emission tomography

    NARCIS (Netherlands)

    Claus, J. J.; Dubois, E. A.; Booij, J.; Habraken, J.; de Munck, J. C.; van Herk, M.; Verbeeten, B.; van Royen, E. A.

    1997-01-01

    Decreased muscarinic receptor binding has been suggested in single-photon emission tomography (SPET) studies of Alzheimer's disease. However, it remains unclear whether these changes are present in mildly demented patients, and the role of cortical atrophy in receptor binding assessment has not been

  1. In vivo measurement of haloperidol affinity to dopamine D2/D3 receptors by [123I]IBZM and single photon emission computed tomography

    DEFF Research Database (Denmark)

    Videbaek, C; Toska, K; Friberg, L

    2001-01-01

    This study examines the feasibility of a steady-state bolus-integration method with the dopamine D2/D3 receptor single photon emission computer tomography (SPECT) tracer, [123I]IBZM, for determination of in vivo affinity of haloperidol. The nonspecific binding of [123I]IBZM was examined in the rat...

  2. Follow-up Thallium-201 scintigraphy after mantle field radiotherapy for Hodgkin's disease

    Energy Technology Data Exchange (ETDEWEB)

    Pierga, J.Y.; Girinski, T.; Henry-Amar, M. (Institut Gustave Roussy, Villejuif (France)); Maunoury, C.; Valette, H.; Tchernia, G.; Desgrez, A. (Centre Hospitalier de Bicetre, Le Kremlin-Bicetre (France)); Socie, G. (Institut Gustave Roussy, Villejuif (France) Hopital St Louis, Paris (France)); Cosset, J.M. (Institut Gustave Roussy, Villejuif (France) Institut Curie, Paris (France))

    1993-04-02

    Assessment of the long-term cardiac effects of mediastinal radiotherapy for Hodgkin's disease, by Thallium scintigraphy. 32 patients (14 males and 18 females) who underwent mantle field radiotherapy for Hodgkin's disease were included in this study. Twenty patients received 4 fractions of 2.5 Gy per week and 12, five fraction of 2 Gy per week, delivered on alternate days. All the patients, except three, performed exercise testing electrocardiogram and Thallium-201 tomoscintigraphy. The average time interval from completion of treatment to the study was 7 years (range 3--13 years). No patients had clinical symptoms of cardiac disease. Mean age at the time of the study was 35 years (range 23--48 years). Two electrocardiograms revealed left bundle branch block and the patients were excluded from the study. Only one out of 27 exercise electrocardiograms was abnormal in a patient with mitral valve prolapse, who was also excluded from the study. Twenty-six scintigraphies were evaluable. Twenty-two (85%) were clearly abnormal with partial or complete redistribution on delayed images. The anterior region was affected in 19 of these cases (86%). Four explorations were undoubtedly normal. Coronary angiography was not performed for ethical reasons in these asymptomatic patients. Despite possible false positive tests, the high rate of abnormality (85%) in this small series is striking. These preliminary data justify larger studies and a close long-term follow-up of these patients. 24 refs., 1 fig., 2 tabs.

  3. Clinicopathologic correlation study of thallium-201 myocardial scintigraphy in diagnosis of myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Chida, Kouji; Sugiura, Masaya; Ohkawa, Shin-ichiro

    1987-05-01

    In a series of 1,000 consecutive autopsy cases, we evaluated the clinical utility of thallium-201 (Tl-201) myocardial scintigraphy and electrocardiography (ECG) in 101 patients who had been studied while alive. Fifty-five cases had myocardial infarctions (MI) at autopsy. The Tl-201 scintigram and ECG in diagnosis of MI showed sensitivities of 68 % and 60 %, specificities of 87 % and 83 %, and diagnostic accuracies of 76 % and 70 %, respectively. The sensitivity of the Tl-201 scintigram was 70 % in anterior MI, 80 % in postero-inferior MI, 25 % in lateral and subendocardial infarction. The sensitivity was 88 % for large massive MI, but was low in scattered (50 %) or middle-sized MI (17 %). The diagnostic limit of the resolution of Tl-201 scintigrams was 4.5 cm in long diameter. All 8 cases with MI of less than 4 cm could not be diagnosed with the technique. There were 48 cases of large MI (more than 5 cm), but 8 cases could not be diagnosed by scintigraphy because of non-transmural or scattered MI. A comparison of the Tl-201 scintigram and ECG showed that 27 cases out of 60 cases were diagnosed by both methods, 14 only by the Tl-201 scintigram, 9 only by ECG and 10 by neither method.

  4. Telecommunication Wavelength-Band Single-Photon Emission from Single Large InAs Quantum Dots Nucleated on Low-Density Seed Quantum Dots.

    Science.gov (United States)

    Chen, Ze-Sheng; Ma, Ben; Shang, Xiang-Jun; He, Yu; Zhang, Li-Chun; Ni, Hai-Qiao; Wang, Jin-Liang; Niu, Zhi-Chuan

    2016-12-01

    Single-photon emission in the telecommunication wavelength band is realized with self-assembled strain-coupled bilayer InAs quantum dots (QDs) embedded in a planar microcavity on GaAs substrate. Low-density large QDs in the upper layer active for ~1.3 μm emission are fabricated by precisely controlling the indium deposition amount and applying a gradient indium flux in both QD layers. Time-resolved photoluminescence (PL) intensity suggested that the radiative lifetime of their exciton emission is 1.5~1.6 ns. The second-order correlation function of g (2)(0) < 0.5 which demonstrates a pure single-photon emission.

  5. Degenerative dementia: nosological aspects and results of single photon emission computed tomography; Les demences degeneratives: aspects nosologiques et resultats de la tomographie d'emission monophotonique

    Energy Technology Data Exchange (ETDEWEB)

    Dubois, B.; Habert, M.O. [Hopital Pitie-Salpetriere, 75 - Paris (France)

    1999-12-01

    Ten years ago, the diagnosis discussion of a dementia case for the old patient was limited to two pathologies: the Alzheimer illness and the Pick illness. During these last years, the frame of these primary degenerative dementia has fallen into pieces. The different diseases and the results got with single photon emission computed tomography are discussed. for example: fronto-temporal dementia, primary progressive aphasia, progressive apraxia, visio-spatial dysfunction, dementia at Lewy's bodies, or cortico-basal degeneration. (N.C.)

  6. Brain single-photon emission tomography with technetium-99m hexamethylpropylene amine oxime in adolscents with intial-stage schizophrenia

    Energy Technology Data Exchange (ETDEWEB)

    Batista, J.F. [Centro de Investigaciones Clinicas, Ciudad Habana (Cuba); Galiano, M.C. [Clinica del Adolescente, Ciudad Habana (Cuba); Torres, L.A. [Centro de Investigaciones Clinicas, Ciudad Habana (Cuba); Hernandez, M.C. [Clinica del Adolescente, Ciudad Habana (Cuba); Sosa, F. [Centro de Investigaciones Clinicas, Ciudad Habana (Cuba); Perera, A. [Centro de Investigaciones Clinicas, Ciudad Habana (Cuba); Perez, M. [Centro de Investigaciones Clinicas, Ciudad Habana (Cuba)

    1995-11-01

    The objective of this study was to search for regional cerebral blood flow (rCBF) abnormalities in adolescents with initial-stage schizophrenia by means of brain single-photon emission tomography (SPET) using technetium-99m hexamethylpropylene amine oxime (HMPAO). SPET studies were performed on a homogeneous sample of 15 carefully selected adolescents with a recent diagnosis of schizophrenia, and without previous electroconvulsive or antipsychotic drug treatment. Computed tomography (CT) and electro-encephalographic (EEG) studies were performed in all patients. Qualitative and semiquantitative analysis of {sup 99m}Tc-HMPAO SPET studies showed an impaired rCBF in 12 patients (80%). The most common pattern was a decreased uptake of {sup 99m}Tc-HMPAO in the frontal lobes, usually in the left hemisphere. Conventional and quantitative EEG was positive in 12 (80%) and 15 (100%) patients, respectively. CT findings were positive in two patients (13%). There was a high level of concordance between SPET and EEG results and between SPET and clinical features (P > 0.05). This study suggests that previously untreated patients in the first stages of schizophrenia present functional abnormalities that are revealed by brain SPET. (orig.)

  7. Intellectual function and radiological images in patients with amyotrophic lateral sclerosis. Special reference to single photon emission computed tomography images

    Energy Technology Data Exchange (ETDEWEB)

    Ichikawa, Hiroo; Kanda, Mikio; Fukui, Toshiya; Sugita, Koujiro [Showa Univ., Tokyo (Japan). School of Medicine

    1994-10-01

    To clarify cognitive decline in amyotrophic lateral sclerosis (ALS), we compared cognitive and motor signs with neuroradiological features, with special reference to single photon emission computed tomography (SPECT), in 23 patients with ALS. Of these 23 patients, five demented patients (ALS-D) showed a decrease in voluntary speech output, abnormal behavior or character change. SPECT images in these patients were specifically characterized by marked uptake reduction in the frontal lobes. ALS patients with normal mentality (ALS-N) showed either a normal pattern or non-specific patchy uptake reduction on SPECT, but never showed the diffuse frontal uptake reduction that was observed in ALS-D patients. None of the ALS-N patients showed cognitive decline or frontal uptake reduction during the follow-up period of up to 29 months. There was no relation in either ALS-D or ALS-N patients between the degree of tracer uptake reduction and clinical features of ALS including severity and duration of illness. Clinical and neuroradiological features in ALS-D patients were compatible with those of `frontal lobe dementia`. ALS-D patients may compose a distinct group because cognitive decline is unlikely to occur in ALS-N patients with a long clinical course. ALS-D patients may be differentiated from other non-demented ALS patients in the early clinical course by the characteristic diffuse frontal uptake reduction on SPECT. (author).

  8. Utility of ictal single photon emission computed tomography in mesial temporal lobe epilepsy with hippocampal atrophy: a randomized trial.

    Science.gov (United States)

    Velasco, Tonicarlo R; Wichert-Ana, Lauro; Mathern, Gary W; Araújo, David; Walz, Roger; Bianchin, Marino M; Dalmagro, Charles L; Leite, Joao P; Santos, Antonio C; Assirati, Joao A; Carlotti, Carlos G; Sakamoto, Americo C

    2011-02-01

    The development of newer diagnostic technologies has reduced the need for invasive electroencephalographic (EEG) studies in identifying the epileptogenic zone, especially in adult patients with mesial temporal lobe epilepsy and hippocampal sclerosis (MTLE-HS). To evaluate ictal single photon emission computed tomography (SPECT) in the evaluation and treatment of patients with MTLE-HS. MTLE patients were randomly assigned to those with (SPECT, n = 124) and without ictal SPECT (non-SPECT, n = 116) in an intent-to-treat protocol. Primary end points were the proportion of patients with invasive EEG studies, and those offered surgery. Secondary end points were the length of hospital stay and the proportion of patients with secondarily generalized seizures (SGS) during video-EEG, postsurgical seizure outcome, and hospital cost. The proportion of patients offered surgery was similar in the SPECT (85%) and non-SPECT groups (81%), as well as the proportion that had invasive EEG studies (27% vs 23%). The mean duration of hospital stay was 1 day longer for the SPECT group (P stay was associated with increased costs and a higher chance of SGS during video-EEG monitoring. These findings support the notion that a protocol including ictal SPECT is equivalent to one without SPECT in the presurgical evaluation of adult patients with MTLE-HS.

  9. Bronchopulmonary dysplasia: clinical grading in relation to ventilation/perfusion mismatch measured by single photon emission computed tomography.

    Science.gov (United States)

    Kjellberg, Malin; Björkman, Karin; Rohdin, Malin; Sanchez-Crespo, Alejandro; Jonsson, Baldvin

    2013-12-01

    Bronchopulmonary dysplasia (BPD) is a significant cause of morbidity in the preterm population. Clinical severity grading based on the need for supplemental oxygen and/or need for positive airway pressure at 36 weeks postmenstrual age does not yield reproducible predictive values for later pulmonary morbidity. Single photon emission computed tomography (SPECT) was used to measure the distribution of lung ventilation (V) and perfusion (Q) in 30 BPD preterm infants at a median age of 37 weeks postmenstrual age. The V and Q were traced with 5 MBq Technegas and Technetium-labeled albumin macro aggregates, respectively, and the V/Q match-mismatch was used to quantify the extent of lung function impairment. The latter was then compared with the clinical severity grading at 36 weeks, and time spent on mechanical ventilation, continuous positive airway pressure (CPAP) and supplemental oxygen. Of those with mild and moderate BPD 3/9 and 3/11 patients, respectively, showed significant V/Q mismatches. By contrast, 4/10 patients with severe BPD showed a satisfactory V/Q matching distribution. An unsatisfactory V/Q match was not correlated with time spent on supplemental oxygen or CPAP, but was significantly negatively correlated with time spent on mechanical ventilation. SPECT provides unique additional information about regional lung function. The results suggest that the current clinical severity grading can be improved and/or complemented with SPECT. © 2013 Wiley Periodicals, Inc.

  10. The clinical meaning of gastric-wall hyperactivity observed on sestamibi cardiac single-photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Cote, C.; Dumont, M. [Centre Hospitalier Universitaire de Quebec, Dept. of Nuclear Medicine, Quebec, Quebec (Canada)]. E-mail: christian.cote@chuq.qc.ca

    2004-06-01

    To evaluate prospectively the incidence and clinical meaning, if any, of gastric-wall hyperactivity observed on sestamibi cardiac single-photon emission computed tomography (SPECT). This phenomenon is completely different from the well-known intraluminal gastric reflux of sestamibi. A group of 819 patients who underwent sestamibi cardiac SPECT was studied from January 2000 to October 2000. Gastric-wall activity was graded qualitatively. Only patients with gastric-wall activity near or equivalent to their heart activity were considered for subsequent analysis. The medical records of patient candidates were reviewed, and their family physicians were asked to respond to a questionnaire by telephone when further information was needed. We identified 13 patients with significant gastric-wall hyperactivity, which was more intense on rest images. Our review of the clinical data shows that all these patients were suffering from dyspepsia and were taking gastric medication. These 13 cases were assigned to 3 groups: gastroesophageal reflux, chronic functional dyspepsia and nonspecific gastritis. Significant gastric-wall hyperactivity is an infrequent observation on sestamibi cardiac SPECT. Our results indicate that the presence of significant gastric-wall hyperactivity is associated with dyspepsia. It is important to realize that this gastric-wall hyperactivity by its proximity to the inferior myocardial wall could in some circumstances lead to either false-negative or false-positive findings, representing a diagnostic problem. Although infrequent, this situation could be avoided by proper quality control, including a systematic review of the raw cine data before reading the images. (author)

  11. Primary lymphedema of the lower limb: The clinical utility of single photon emission computed tomography/CT

    Energy Technology Data Exchange (ETDEWEB)

    Weiss, Mayo; Baumeister, Ruedinger G. H.; Frick, Andreas; Wallmichrath, Jens; Bartenstein, Peter; Rominger, Axel [Ludwig-Maximilians-University of Munich, Muenchen (Germany)

    2015-02-15

    The aim of this prospective study was to determine whether the additional use of the single photon emission computed tomography/CT (SPECT/CT) technique improves the diagnostic value of planar lymphoscintigraphy in patients presenting with primary lymph edema of the lower limb. For a defined period of three years (April 2011-April 2014) a total of 34 consecutive patients (28 females; age range, 27-83 years) presenting with swelling of the leg(s) suspicious of (uni- or bilateral, proximal or distal) primary lymphedema were prospectively examined by planar lymphoscintigraphy (lower limbs, n = 67) and the tomographic SPECT/CT technique (anatomical sides, n = 65). In comparison to pathological planar scintigraphic findings, the addition of SPECT/CT provided relevant additional information regarding the presence of dermal backflow (86%), the anatomical extent of lymphatic disorders (64%), the presence or absence of lymph nodes (46%), and the visualization of lymph vessels (4%). As an adjunct to planar lymphoscintigraphy, SPECT/CT specifies the anatomical correlation of lymphatic disorders and thus improves assessment of the extent of pathology due to the particular advantages of tomographic separation of overlapping sources. The interpretation of scintigraphic data benefits not only in baseline diagnosis, but also in physiotherapeutical and microsurgical treatments of primary lymphedema.

  12. Technetium-99m sestamibi single-photon emission tomography detects subclinical myocardial perfusion abnormalities in patients with systemic lupus erythematosus

    Energy Technology Data Exchange (ETDEWEB)

    Schillaci, O. [Nuclear Medicine, University of l`Aquila (Italy); Lagana, B.; Gentile, R.; Tubani, L.; Baratta, L. [Department of Clinical Medicine, University ``La Sapienza``, Rome (Italy); Danieli, R.; Scopinaro, F. [Section of Nuclear Medicine, Department of Experimental Medicine and Pathology, University ``La Sapienza``, Rome (Italy)

    1999-07-01

    In patients with systemic lupus erythematosus, involvement of the cardiovascular system is the third leading cause of death. However, although autopsy studies have demonstrated a high incidence of abnormalities in both the myocardium and coronary vessels, clinical manifestations have been reported in only a small percentage of cases. The aim of this study was to evaluate myocardial perfusion in asymptomatic lupus patients using technetium-99m sestamibi single-photon emission tomography (SPET). Twenty-eight patients without overt cardiac involvement and risk factors were studied with {sup 99m}Tc-sestamibi SPET at rest and after dipyridamole infusion. Perfusion abnormalities were detected in 18 cases: six had persistent defects, three had reversible defects, seven had both persistent and reversible defects, and two showed rest defects which normalized on dipyridamole images (``reverse redistribution pattern``). Coronary angiography was performed in eight patients with positive {sup 99m}Tc-sestamibi SPET, and showed normal epicardial vessels in all the cases. These results indicate that {sup 99m}Tc-sestamibi SPET reveals a high prevalence (18 out of 28 patients in this study, i.e. 64%) of myocardial perfusion abnormalities in asymptomatic lupus patients, probably due to the primary immunological damage of this autoimmune disease. In conclusion, rest/dipyridamole {sup 99m}Tc-sestamibi SPET can be a useful non-invasive method to identify subclinical myocardial involvement in systemic lupus erythematosus, and patients potentially at risk of later cardiac events. (orig.) With 2 figs., 2 tabs., 21 refs.

  13. Technetium-99m hexamethylpropylene amine oxime ( sup 99m -Tc-HMPAO) single photon emission tomography (SPET) in febrile convulsions

    Energy Technology Data Exchange (ETDEWEB)

    Dierckx, R.A.; Vandevivere, J. (Middelheim General Hospital, Antwerp (Belgium). Dept. of Nuclear Medicine); Melis, K.; Janssens, G. (Children' s Hospital Antwerp (Belgium)); Dom, L. (Children' s Hospital Antwerp (Belgium) Middelheim General Hospital, Antwerp (Belgium). Dept. of Neurology); Luysterborgh, E. (Middelheim General Hospital, Antwerp (Belgium). Dept. of Neurology); Deyn, P.P. de (Middelheim General Hospital, Antwerp (Belgium). Dept. of Neurology Antwerp Univ. (Belgium). Lab. of Neurochemistry)

    1992-04-01

    We report our initial experience with technetium-99m hexamethyl propylene amine oxime ({sup 99m}Tc-HMPAO) brain single photon emission tomography (SPET) in the investigation of 19 children presenting with febrile convulsions. Two patients with complex febrile convulsions showed focal SPET lesions contralateral to the neurological deficit. However, in 9 out of 17 patients with simple febrile convulsions, focally disturbed perfusion was shown. in 4 out of 6 patients with electroencephalogram (EEG) abnormalities on admittance, SPET revealed at least 2 focal lesions. The temporofrontal region was the one most commonly involved. The SPET findings presented here also suggest a temporal relationship with the febrile convulsions, with markedly fewer lesions if examined after 12 days. In our initial experience, perfusion SPET did not show any particular pattern helpful in the differential diagnosis of the child presenting with febrile convulsions. Physiopathologically, our findings may support the hypothesis that brain tissue is regionally more vulnerable to fever, in patients presenting with febrile convulsions. (orig.).

  14. Correlation between severity of carotid stenosis and vascular reserve measured by acetazolamide brain perfusion single photon emission computed tomography.

    Science.gov (United States)

    Tomura, Noriaki; Otani, Takahiro; Koga, Makoto; Ishiyama, Koichi

    2013-02-01

    Few studies have investigated the relationship between the degree of stenosis of the internal carotid artery (ICA) and cerebrovascular reserve (CVR). This study examined that relationship. A total of 56 ICAs in 43 patients were included. Computed tomography scan or magnetic resonance imaging showed no evidence of infarction in any of these patients. Both iodine-123-N-isopropyl-p-iodoamphetamine ((123)IMP)-single photon emission computed tomography (SPECT) in the resting state and (123)IMP-SPECT with acetazolamide (ACZ) enhancement were performed. Quantitated cerebral blood flow (CBF) images were acquired with the (123)IMP autoradiography technique. The mean CBF without ACZ administration (resting CBF) and CVR in the middle cerebral artery territory were calculated using stereotactic extraction estimation (SEE) analysis software. The degree of stenosis in the origin of the ICA was calculated from intra-arterial digital subtraction angiography. Resting CBF was not correlated with the degree of ICA stenosis; however, nonlinear regression analysis (second-order equation) showed a moderate correlation between CVR and the degree of ICA stenosis. In 72% of the cases with a CVR 74%. Using the SEE method, CVR was moderately correlated with the degree of ICA stenosis. Our findings indicate that evaluating CVR by ACZ-enhanced (123)IMP-SPECT in patients with ICA stenosis is of clinical value. Copyright © 2013 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  15. Evaluation of dysthymic disorder with technetium-99 m hexamethylpropylene amine oxime brain single-photon emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Sarikaya, A.; Cermik, T.F. [Department of Nuclear Medicine, Trakya University, Faculty of Medicine, Edirne (Turkey); Karasin, E.; Abay, E. [Department of Psychiatry, Trakya University, Faculty of Medicine, Edirne (Turkey); Berkarda, S.

    1999-03-01

    Dysthymic disorder is a chronic disorder characterised by the presence of a depressed mood and is classified as a distinct category in DSM-IV, separately from major depression. Although brain imaging studies have been performed in major depressive disease, there have to date been no reports of such studies in dysthymic disorder. In this study 36 patients with dysthymic disorder were compared with 16 normal subjects using technetium-99m hexamethylpropylene amine oxime brain single-photon emission tomography. A relative blood flow ratio was calculated for each region of interest using the average tissue activity in the region divided by activity in the cerebellum. There were significant differences in the bilateral inferior frontal, bilateral parietal, right superior frontal and left posterior temporal regions in the patients with dysthymic disorder compared with the healthy controls. These findings support the hypothesis that the biological bases for dysthymic disorder and major depression are similar. Recognition of these regional abnormalities may have clinical utility in both the diagnosis and the treatment of dysthymic disorder. Further studies are needed to confirm our results and to assess the influence of treatment in patients with dysthymic disorder. (orig.) With 1 fig., 1 tab., 26 refs.

  16. Technetium-99m Methylene Diphosphonate Single-photon Emission Computed Tomography/Computed Tomography of the Foot and Ankle.

    Science.gov (United States)

    Upadhyay, Bhavin; Mo, Jonathan; Beadsmoore, Clare; Marshall, Tom; Toms, Andoni; Buscombe, John

    2017-01-01

    The complex anatomy and function of the foot and ankle can make it difficult to determine the cause of symptoms in patients with foot and ankle pathology. Following initial clinical and radiographic assessment, additional imaging with magnetic resonance imaging may be required, which is often seen as the modality of choice. Although sensitive to pathological changes in bone metabolism and vascularity, technetium-99m (Tc-99m) bone scintigraphy often lacks the specificity and resolution required to evaluate the structures of the foot and ankle. Tc-99m methylene diphosphonate single-photon emission computed tomography/computed tomography (SPECT/CT) combines this sensitivity with the superior anatomical detail of CT, enabling better localization of pathological uptake and evaluation of associated structural changes. As a result, SPECT/CT has been growing in popularity for the assessment of patients with foot and ankle pathology where it can provide additional information that may change the initial diagnosis and subsequent management plan. Studies have reported modification of the surgical approach and site of intra-articular local anesthetic injections following SPECT/CT with good results. Interpretation of SPECT/CT studies requires an understanding of the pathological changes that result in increased tracer accumulation in addition to the CT changes that may be seen. This review aims to highlight the advantages of SPECT/CT, potential applications and explain the imaging appearances of common pathologies that may be observed.

  17. CdSe quantum dot in vertical ZnSe nanowire and photonic wire for efficient single-photon emission

    DEFF Research Database (Denmark)

    Cremel, Thibault; Bellet-Amalric, Edith; Cagnon, Laurent

    as a single photon source. We have grown vertically oriented ZnSe NWs (with typical diameter of 10 nm) by molecular beam epitaxy on a ZnSe(111)B buffer layer. The growth of a ZnMgSe passivating shell increases the (otherwise weak) ZnSe near-band-edge luminescence by two orders of magnitude. This has allowed...... us to observe luminescence for the first time from CdSe/ZnSe NW-QDs in the (111) direction. We managed to obtain a low NW density (~ 1 NW/4 μm2) so that single NW-QDs can be directly studied on the as-grown sample. Exciton, biexciton and charged exciton lines are clearly identified. Then we obtained...... conformal dielectric coating of Al2O3 on the NW-QDs using Atomic Layer Deposition so that a photonic wire is formed with the CdSe QD deterministically positioned on its axis. The collection enhancement effect is studied by measuring the emission (with pulse excitation, at saturation intensity) of single...

  18. Effects of functionalization and side defects on single-photon emission in boron nitride quantum dots

    Science.gov (United States)

    Shayeganfar, Farzaneh; Rahimi Tabar, M. Reza; Simchi, A.; Beheshtian, Javad

    2017-10-01

    Boron nitride quantum dots (BNQDs) functionalized with chemical ligands exhibit intriguing optoelectronic properties due to the quantum confinement effect. This paper presents peculiar insights on the effect of side defects on the electronic structure and optical properties of BNQDs functionalized with different chemical bonds including hydrogen (H), nitrogen (N), hydroxyl (OH), amine (NH2), and thiol groups (inspired by experimental reports of functionalized BN nanosheets and nanotubes) Weng et al., Chem. Soc. Rev. 45, 3989 (2016), 10.1039/C5CS00869G. Hybrid density functional simulations and Green's function calculations indicate an intriguing coexistence of two different Peierls-like distortions in the functionalized low-dimensional material. The presence of side defects increases the side strain and creates interband electronic states. As a result, the band gap of BNQDs could vary in a wide range depending on the type of chemical bonds and surface disorders. Enhanced edge states also improve the photoluminescence emission of the quantum dots. These side-defect enriched states in BNQDs create optical and electrical responses which could offer unprecedented potential for large scale nanophotonics such as photovoltaic, bioimaging, and quantum communication.

  19. Thallium-201 for cardiac stress tests: residual radioactivity worries patients and security.

    Science.gov (United States)

    Geraci, Matthew J; Brown, Norman; Murray, David

    2012-12-01

    A 47-year-old man presented to the Emergency Department (ED) in duress and stated he was "highly radioactive." There were no reports of nuclear disasters, spills, or mishaps in the local area. This report discusses the potential for thallium-201 (Tl-201) patients to activate passive radiation alarms days to weeks after nuclear stress tests, even while shielded inside industrial vehicles away from sensors. Characteristics of Tl-201, as used for medical imaging, are described. This patient was twice detained by Homeland Security Agents and searched after he activated radiation detectors at a seaport security checkpoint. Security agents deemed him not to be a threat, but they expressed concern regarding his health and level of personal radioactivity. The patient was subsequently barred from his job and sent to the hospital. Tl-201 is a widely used radioisotope for medical imaging. The radioactive half-life of Tl-201 is 73.1h, however, reported periods of extended personal radiation have been seen as far out as 61 days post-administration. This case describes an anxious, but otherwise asymptomatic patient presenting to the ED with detection of low-level personal radiation. Documentation should be provided to and carried by individuals receiving radionuclides for a minimum of five to six half-lives of the longest-lasting isotope provided. Patients receiving Tl-201 should understand the potential for security issues; reducing probable tense moments, confusion, and anxiety to themselves, their employers, security officials, and ED staff. Copyright © 2012 Elsevier Inc. All rights reserved.

  20. Reproducibility of serial peri-ictal single-photon emission tomography difference images in epilepsy patients undergoing surgical resection

    Energy Technology Data Exchange (ETDEWEB)

    Avery, R.A.; Studholme, C.; Stokking, R.; Morano, G.; Corsi, M.; Seibyl, J.P.; Zubal, I.G. [Dept. of Diagnostic Radiology, Yale University School of Medicine, New Haven, CT (United States); Spencer, S.S. [Dept. of Neurology, Yale University School of Medicine, New Haven, CT (United States); Spencer, D.D. [Dept. of Neurosurgery, Yale University School of Medicine, New Haven, CT (United States)

    2000-01-01

    Peri-ictal single-photon emission tomography (SPET) difference images co-registered to magnetic resonance imaging (MRI) visualize regional cerebral blood flow (rCBF) changes and help localize the epileptogenic area in medically refractory epilepsy. Few reports have examined the reproducibility of SPET difference image results. Epilepsy patients having two peri-ictal and at least one interictal SPET scan who later underwent surgical resection were studied. Localization accuracy of peri-ictal SPET difference images results, interictal electroencephalography (EEG), and ictal EEG from the first (seizure 1) and second (seizure 2) seizure, as well as MRI and positron emission tomography (PET) findings, were compared using surgical resection site as the standard. Thirteen patients underwent surgical resection (11 temporal lobe and 2 extratemporal). SPET results from seizure 1 were localized to the surgical site in 12/13 (92%) patients, while SPET results from seizure 2 were localized in 13/13 (100%) patients. All other modalities were less accurate than the SPET results [interictal EEG - seizure 1 6/13 (46%); ictal EEG - seizure 1 5/13 (38%); interictal intracranial EEG - seizure 2 4/9 (44%); ictal intracranial EEG - seizure 2 results 8/9 (89%); MRI 6/13 (46%); PET 9/13 (69%)]. SPET results were reproducible in 12/13 (92%) patients. SPET difference images calculated from two independent peri-ictal scans appear to be reproducible and accurately localize the epileptogenic area. While SPET difference images visualize many areas of rCBF change, the quantification of these results along with consideration of injection time improves the diagnostic interpretation of the results. (orig.)

  1. Incorporating quantitative single photon emission computed tomography into radiation therapy treatment planning for lung cancer: impact of attenuation and scatter correction on the single photon emission computed tomography-weighted mean dose and functional lung segmentation.

    Science.gov (United States)

    Yin, Lingshu; Shcherbinin, Sergey; Celler, Anna; Thompson, Anna; Fua, Tsien-Fei; Liu, Mitchell; Duzenli, Cheryl; Gill, Brad; Sheehan, Finbar; Powe, John; Worsley, Daniel; Marks, Lawrence; Moiseenko, Vitali

    2010-10-01

    To assess the impact of attenuation and scatter corrections on the calculation of single photon emission computed tomography (SPECT)-weighted mean dose (SWMD) and functional volume segmentation as applied to radiation therapy treatment planning for lung cancer. Nine patients with lung cancer underwent a SPECT lung perfusion scan. For each scan, four image sets were reconstructed using the ordered subsets expectation maximization method with attenuation and scatter corrections ranging from none to a most comprehensive combination of attenuation corrections and direct scatter modeling. Functional volumes were segmented in each reconstructed image using 10%, 20%, …, 90% of maximum SPECT intensity as a threshold. Systematic effects of SPECT reconstruction methods on treatment planning using functional volume were studied by calculating size and spatial agreements of functional volumes, and V(20) for functional volume from actual treatment plans. The SWMD was calculated for radiation beams with a variety of possible gantry angles and field sizes. Functional volume segmentation is sensitive to the particular method of SPECT reconstruction used. Large variations in functional volumes, as high as >50%, were observed in SPECT images reconstructed with different attenuation/scatter corrections. However, SWMD was less sensitive to the type of scatter corrections. SWMD was consistent within 2% for all reconstructions as long as computed tomography-based attenuation correction was used. When using perfusion SPECT images during treatment planning optimization/evaluation, the SWMD may be the preferred figure of merit, as it is less affected by reconstruction technique, compared with threshold-based functional volume segmentation. 2010 Elsevier Inc. All rights reserved.

  2. Biphasic thallium 201 SPECT-imaging for the noninvasive diagnosis of myocardial perfusion abnormalities in a child with Kawasaki disease--a case report

    Energy Technology Data Exchange (ETDEWEB)

    Hausdorf, G.; Nienaber, C.A.; Spielman, R.P.

    1988-02-01

    The mucocutaneous lymph node syndrome (Kawasaki disease) is of increasing importance for the pediatric cardiologist, for coronary aneurysms with the potential of thrombosis and subsequent stenosis can develop in the course of the disease. The authors report a 2 1/2-year-old female child in whom, fourteen months after the acute phase of Kawasaki disease, myocardial infarction occurred. Biphasic thallium 201 SPECT-imaging using dipyridamole depicted anterior wall ischemia and inferolateral infarction. This case demonstrates that noninvasive vasodilation-redistribution thallium 201 SPECT-imaging has the potential to predict reversible myocardial perfusion defects and myocardial necrosis, even in small infants with Kawasaki disease.

  3. Blue single photon emission up to 200 K from an InGaN quantum dot in AlGaN nanowire

    Energy Technology Data Exchange (ETDEWEB)

    Deshpande, Saniya; Das, Ayan; Bhattacharya, Pallab [Center for Photonics and Multiscale Nanomaterials, Department of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, Michigan 48109-2122 (United States)

    2013-04-22

    We demonstrate polarized blue single photon emission up to 200 K from an In{sub 0.2}Ga{sub 0.8}N quantum dot in a single Al{sub 0.1}Ga{sub 0.9}N nanowire. The InGaN/AlGaN dot-in-nanowire heterostructure was grown on (111) silicon by plasma assisted molecular beam epitaxy. Nanowires dispersed on a silicon substrate show sharp exciton and biexciton transitions in the micro-photoluminescence spectra. Second-order correlation measurements performed under pulsed excitation at the biexciton wavelength confirm single photon emission, with a g{sup (2)}(0) of 0.43 at 200 K. The emitted photons have a short radiative lifetime of 0.7 ns and are linearly polarized along the c-axis of the nanowire with a degree of polarization of 78%.

  4. Pulmonary ventilation/perfusion single photon emission tomography – Initial experience of a Nuclear Medicine Department

    Directory of Open Access Journals (Sweden)

    J. G. Santos

    2016-01-01

    Full Text Available Introduction: Lung ventilation/perfusion scintigraphy with planar images (V/QS-planar is very useful for the diagnosis and follow-up of pulmonary thromboembolism (PTE. Acquiring tomographic images (V/QS-SPECT is a recent development with potential to increase the technique's accuracy. The purpose of this work is to evaluate the added benefits of V/QS-SPECT studies as opposed to traditional planar imaging. Patients and methods: We prospectively revised 53 V/QS-planar and V/QS-SPECT exams, performed according to the European Association of Nuclear Medicine guidelines. We evaluated the exams independently, by consensus of two Nuclear Medicine physicians. For both methods, we gave each lung a score expressing the dimension and extension of perfusion defects with normal ventilation. For each lung, we compared the scores with the paired Wilcoxon test, estimating the 95% confidence interval (95CI for the respective difference. Results: We performed V/QS-SPECT exams without technical difficulties. The paired Wilcoxon test estimated the score difference to be −0.75 (95CI of −1.0 to −0.5; p-value = 9.6 × 10−7, expressing a statistically significant difference of about 1 subsegmental defect between both methods, with V/QS-SPECT detecting more defects. Discussion: The results demonstrate that V/QS-SPECT identifies a slightly larger number of perfusion defects than V/QS-planar, suggesting a higher sensitivity of this technique. However, more studies are necessary to evaluate the clinical meaning of this fact. Conclusion: V/QS-SPECT demonstrates a higher capability to identify perfusion defects. This method looks promising, allowing for a greater role of this exam in pulmonary thromboembolism diagnosis and follow-up. Keywords: Pulmonary thromboembolism, Lung, Scintigraphy, Single-photon emission-computed tomography (SPECT

  5. Standardization of quantitative single photon emission computed tomography in control individuals and in patients with condylar hyperplasia.

    Science.gov (United States)

    AlSharif, Abedallatif A; Tarawneh, Emad S; AlKawaleet, Yazan I; Abukaraky, Ashraf E; AlAhmad, Hazem T; Malkawi, Ziad A; Juweid, Malik E

    2014-12-01

    The aim of the study was to evaluate the diagnostic accuracy of various single photon emission computed tomography (SPECT) quantitative methods in patients with condylar hyperplasia (CH) and to investigate whether normal condylar activity changes with age. We analyzed the SPECT images of 33 patients with CH and those of 16 control individuals. Regions of interest (ROIs) were drawn on whole condyle, or fixed-size ROIs were drawn on both condyles and the clivus on the slice with higher activity [a two-dimensional (2D) approach] and on the summation of five adjacent transaxial slices [a three-dimensional (3D) approach]. A percentage difference between both condyles of above 10% or a cutoff value of 1.44 or 1.88 for abnormal condyle/clivus ratio was considered abnormal. Seventeen patients with active CH, 16 with inactive CH, and 16 control individuals were evaluated. The highest sensitivity and highest specificity were observed for the whole-condyle approach (88 and 87%, respectively), followed by the percentage 2D maximum condyle/total (82.4 and 81.3%, respectively). The condyle/clivus ratio yielded low sensitivity for both 2D and 3D approaches. No effect of age on condylar activity was demonstrated. No statistically significant difference in condyle/clivus ratio was evident between patients with active and those with inactive CH. Use of 2D maximum fixed-size ROI and percentual difference in condylar activity offers optimal diagnostic accuracy in patients with CH and should be encouraged in future studies. The condyle/clivus ratio offers suboptimal results and cannot, therefore, be recommended. No effect of age on normal condylar activity was demonstrated.

  6. Iodine-123-labelled fatty acids for myocardial single-photon emission tomography: current status and future perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Knapp, F.F. Jr. [Nuclear Medicine Group, Health Sciences Research Div., Oak Ridge National Lab. (ORNL), TN (United States); Kropp, J. [Klinik und Poliklinik fuer Nuklearmedizin des Universitaetsklinikums der Technischen Univ., Dresden (Germany)

    1995-04-01

    Renewed interest in the clinical use of iodine-123-labelled fatty acids is currently primarily focused on the use of iodine-123-labelled 15-(p-iodophenyl)pentadecanoic acid (IPPA) and ``modified`` fatty acid analogues such as 15-(p-iodophenyl)-3-R,S-methylpentadecanoic acid (BMIPP) which show delayed myocardial clearance, thus permitting single-photon emission tomographic imaging. Interest in the use of BMIPP and similar agents results from the differences which have often been observed in various types of heart disease between regional myocardial uptake patterns of [{sup 123}I]BMIPP and flow tracer distribution. Although the physiological basis is not completely understood, differences between regional fatty acid and flow tracer distribution may reflect alterations in important parameters of metabolism which can be useful for patient management or therapy planning. These tracers may also represent unique metabolic probes for correlation of energy substrate metabolism with regional myocardial viability. The two agents currently most widely used clinically are {sup 123}I-labelled IPPA and BMIPP. While [{sup 123}I]IPPA is commercially available as a radiopharmaceutical in Europe (Cygne) and Canada (Nordion), multicenter trials are in progress in the United States as a prelude to approval for broad use. [{sup 123}I]BMIPP was recently introduced as Cardiodine for commercial distribution in Japan (Nihon Medi-Physics, Inc.). [{sup 123}I]BMIPP is also being used in clinical studies on an institutional approval basis at several institutions in Europe and the United States. In this review, the development of a variety of radioiodinated fatty acids is discussed. The results of clinical trials with [{sup 123}I]IPPA and [{sup 123}I]BMIPP are discussed in detail, as are the future prospects for fatty acid imaging. (orig.)

  7. Factors determining altered perfusion after acute pulmonary embolism assessed by quantified single-photon emission computed tomography-perfusion scan

    Science.gov (United States)

    Meysman, Marc; Everaert, Hendrik; Vincken, Walter

    2017-01-01

    AIM OF THE STUDY: The aim of the study was to analyze the evolution of perfusion (Q)-defects in patients treated for acute pulmonary embolism (PE), correlation with baseline parameters and evaluation of recurrence risk. METHODS: This is a single-center prospective observational cohort study in symptomatic normotensive PE. Comparison of the ventilation/perfusion single-photon emission computed tomography (V/Q-SPECT) acquired at baseline with a quantified SPECT (Q-SPECT) repeated at 1 week and 6 months. The Q-defect extent (percentage of total lung volume affected) was measured semiquantitatively. Data collected at baseline were age, gender, body mass index (BMI), history of previous venous thromboembolism (HVTE), Charlson's Comorbidity Score (CcS), plasma troponin-T and D-dimer levels, PE Severity Index, and tricuspid regurgitation jet (TRJ) velocity. RESULTS: Forty-six patients (22 men/24 women, mean age 61.7 years (± standard deviation 16.3)) completed the study. At 1 week, 13/46 (28.3 %) and at 6 months 22/46 (47.8%) patients had completely normalized Q-SPECT. Persistence of Q-defects was more frequent in female patients in univariate and multivariate analysis. We found no correlation between the persistence of Q-defects on Q-SPECT and HVTE, BMI, plasma troponin-T, and CcS. However, lower TRJ and younger age were statistically significantly linked to normalization of Q-scans after 6 months of treatment only in univariate analysis. There is no difference in the frequency of recurrent PE in relation to the persistence of Q-defects. CONCLUSION: Acute PE patients of female, older age, and higher TRJ in univariate analysis and patients of female in multivariate analysis seem to have a higher risk of persistent Q-defects after 6 months treatment. The presence of residual Q-abnormalities at 6 months was not associated with an increased risk for recurrent PE. PMID:28197219

  8. A randomized, multicenter, multivendor study of myocardial perfusion imaging with regadenoson CT perfusion vs single photon emission CT.

    Science.gov (United States)

    Cury, Ricardo C; Kitt, Therese M; Feaheny, Kathleen; Blankstein, Ron; Ghoshhajra, Brian B; Budoff, Matthew J; Leipsic, Jonathon; Min, James K; Akin, Jamie; George, Richard T

    2015-01-01

    Myocardial CT perfusion (CTP) is a promising tool for the detection of myocardial ischemia. We hypothesize that regadenoson CTP is noninferior to regadenoson single photon emission CT (SPECT) for detecting or excluding myocardial ischemia. Patients (men ≥ 45 years; women ≥ 50 years) with known or suspected coronary artery disease (n = 124) were randomized to 1 of 2 diagnostic sequences: rest and regadenoson SPECT on day 1, then regadenoson CTP and rest CTP (and coronary CT angiography [CTA]) (CTA; same acquisition) on day 2 or regadenoson CTP and rest CTP (and CTA) on Day 1, then rest and regadenoson SPECT on day 2. Scanning platforms included 64-, 128-, 256-, and 320-slice systems. The primary analysis examined the agreement rate between CTP and SPECT for detecting or excluding reversible ischemia in ≥ 2 myocardial segments as assessed by independent, blinded readers. Complete and interpretable CTP and SPECT scans were obtained for 110 patients. Regadenoson CTP was noninferior to SPECT for detecting or excluding reversible ischemia with an agreement rate of 0.87 (95% confidence interval [CI], 0.77-0.97) and sensitivity and specificity of 0.90 (95% CI, 0.71-1.00) and 0.84 (95% CI, 0.77-0.91), respectively. The agreement rate for detecting or excluding ≥ 1 fixed defects by regadenoson CTP and SPECT was 0.86 (95% CI, 0.74-0.98). With SPECT as the reference standard, the diagnostic accuracies for detecting or excluding ischemia by regadenoson CTP and CTA alone were 0.85 (95% CI, 0.78-0.91) and 0.69 (95% CI, 0.60-0.77), respectively. This study establishes the noninferiority of regadenoson CTP to SPECT for detecting or excluding myocardial ischemia. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  9. Transient Ischemic Dilation Ratio in Regadenoson, Single Isotope Gated Single-photon Emission Computed Tomography Myocardial Perfusion Imaging.

    Science.gov (United States)

    Rubio, Manolo; Dias, Andre; Koshkelashvili, Nikoloz; Codolosa, Jose N; Jalife-Bucay, Mauricio; Rodriguez-Ziccardi, Mary; Amanullah, Aman M

    2017-01-01

    Single isotope 99mTc single-photon emission computed tomography-myocardial perfusion imaging (SPECT-MPI) is the most commonly used protocol for nuclear stress testing. Transient ischemic dilation of the left ventricle (TID) has been considered a specific marker of severe coronary artery disease (CAD). Recent publications have questioned the clinical utility of TID, specifically with regadenoson as a stressor and 4DM-SPECT software for TID analysis. These findings have not been demonstrated using other imaging packages. The goal of our study was to establish the TID threshold in the identification of Multi-vessel CAD using Quantitative Perfusion SPECT (QPS) software. Included in this study are 190 patients that had undergone regadenoson-stress, same day, single-isotope 99mTc MPI and had a coronary angiography within a designated 3-month period. QPS (Cedars-Sinai, LA, CA) automated image analysis software was used to calculate TID ratios which were compared across different CAD categories. Coronary angiograms were reviewed to identify both obstructive and nonobstructive CAD. The mean TID for patients with nonobstructive CAD ( n = 91) was 1.02 ± 0.11, and the threshold for TID was 1.24. A receiver operating characteristic curve showed that TID had a poor discriminatory capacity to identify MVD (area under the curve 0.58) with a sensitivity of 3% and a specificity of 97%. In our study with regadenoson MPI in a predominantly African-American population, TID was found to be a poor predictor of MVD using QPS software. The reason is unclear but possibly related to the significant decline in the prevalence of severe CAD in the area where our study took place.

  10. Cerebral blood flow single-photon emission tomography with {sup 123}I-IMP in vascular dementia

    Energy Technology Data Exchange (ETDEWEB)

    Kawahata, Nobuya; Gotoh, Chiharu; Yokoyama, Sakura; Daitoh, Nobuyuki [Narita Memorial Hospital, Toyohashi, Aichi (Japan)

    2001-06-01

    Cerebral blood flow differences between patients with vascular dementia, patients with multiple lacunar infarction without cognitive dysfunction, and age-matched controls were examined. Thirty four patients with vascular dementia (VD) were selected from consecutive referrals to the Memory Clinic at Narita Memorial Hospital. All the patients had routine assessment including history, physical and neurological examinations, neuropsychological assessment, blood tests, EEG, head MRI, and single photon emission computed tomography (SPECT). All of them fulfilled the NINDS-AIREN diagnostic criteria for vascular dementia. Thirty nine patients with multiple lacunar infarction without cognitive dysfunction and 110 age-matched controls were included in this study. Mean cerebral blood flow (mCBF) and regional cerebral blood flow (rCBF) were measured using N-isopropyl-P-{sup 123}I-iodoamphetamine ({sup 123}I-IMP) and SPECT imager. The mCBF in VD was 27.6{+-}5.3 ml/100 g/min, while those in the control group and multiple lacunar infarction without cognitive dysfunction were 36.6{+-}6.1 ml/100 g/min and 32.5{+-}5.5 ml/100 g/min, respectively. The patients with VD demonstrated significantly reduced mCBF and rCBF in twenty regions including both cerebellar hemispheres as compared with those of the control group. Although there was no significant rCBF differences in bilateral inferior occipital regions and the right cerebellar hemisphere between patients with VD and multiple lacunar infarction without cognitive dysfunction, we could find significant lower rCBF in the remaining brain areas. In spite of the severity of VD, the diffuse decrease of cerebral blood flow was recognized in all patients with VD. (author)

  11. The Prognostic Role of Magnetic Resonance Imaging and Single-Photon Emission Computed Tomography in Viral Encephalitis

    Energy Technology Data Exchange (ETDEWEB)

    Misra, U.K.; Kalita, J.; Srivastav, A.; Pradhan, P.K. (Depts. of Neurology and Nuclear Medicine, Sanjay Gandhi Post Graduate Inst. of Medical Sciences, Lucknow (India))

    2008-09-15

    Background: There is a paucity of studies evaluating the prognostic role of magnetic resonance imaging (MRI) and single-photon emission computed tomography (SPECT) changes in viral encephalitis. Purpose: To study MRI and SPECT changes in patients with viral encephalitis, and to correlate these changes with clinical findings and outcome. Material and Methods: During 1997-2006, 31 encephalitis patients (aged 2-60 years; nine females, 22 males) underwent both MRI and SPECT studies. Their demographic and clinical data and 6-month outcome were recorded. For the diagnosis of encephalitis, polymerase chain reaction (PCR) and IgM enzyme-linked immunosorbent assay (ELISA) were carried out. Cranial MRI was done on a 1.5 T scanner, and 99mTc ethylene cysteine dimer (ECD) SPECT using a gamma camera. Outcome was defined at 6 months as complete, partial, or poor recovery. Results: 19 patients had Japanese encephalitis (JE), one had herpes simplex encephalitis (HSE), and 11 had nonspecific encephalitis. Movement disorders were present in 21, parkinsonian features in 19, and dystonia in 16 patients. MRI was abnormal in 20 patients, and revealed thalamic involvement in 17, basal ganglia in eight, brainstem in 11, and cortical in two. SPECT revealed hypoperfusion in 22 patients, which was cortical in 11, thalamic in 10, basal ganglia in six, and midbrain in one. Cortical involvement was more frequently found by SPECT and brainstem involvement by MRI. Outcome of encephalitis did not differ in the different groups of encephalitis and MRI changes. Conclusion: MRI and SPECT show a spectrum of findings in encephalitis, but these do not correlate with 6-month outcome

  12. Use of measured scatter data for the attenuation correction of single photon emission tomography without transmission scanning.

    Science.gov (United States)

    Cade, Sarah C; Arridge, Simon; Evans, Martyn J; Hutton, Brian F

    2013-08-01

    distinguished in a real situation and produces results that represent a promising first step toward the use of scatter data to estimate the activity distribution and attenuation map from single photon emission tomography (SPECT) data without a transmission scan. The technique presented shows promise as a method of attenuation correction for SPECT data without the need for a separate transmission scan. Further work is required to further improve the method and to compensate for the assumptions used in the scatter model.

  13. Pentoxifylline (Trental) does not inhibit dipyridamole-induced coronary hyperemia: Implications for dipyridamole-thallium-201 myocardial imaging

    Energy Technology Data Exchange (ETDEWEB)

    Brown, K.A.; Slinker, B.K. (Univ. of Vermont College of Medicine, Burlington (USA))

    1990-06-01

    Dipyridamole-thallium-201 imaging is often performed in patients unable to exercise because of peripheral vascular disease. Many of these patients are taking pentoxifylline (Trental), a methylxanthine derivative which may improve intermittent claudication. Whether pentoxifylline inhibits dipyridamole-induced coronary hyperemia like other methylxanthines such as theophylline and should be stopped prior to dipyridamole-thallium-201 imaging is unknown. Therefore, we studied the hyperemic response to dipyridamole in seven open-chest anesthetized dogs after pretreatment with either pentoxifylline (0, 7.5, or 15 mg/kg i.v.) or theophylline (3 mg/kg i.v.). Baseline circumflex coronary blood flows did not differ significantly among treatment groups. Dipyridamole significantly increased coronary blood flow before and after 7.5 or 15 mm/kg i.v. pentoxifylline (p less than 0.002). Neither dose of pentoxifylline significantly decreased the dipyridamole-induced hyperemia, while peak coronary blood flow was significantly lower after theophylline (p less than 0.01). We conclude that pentoxyifylline does not inhibit dipyridamole-induced coronary hyperemia even at high doses.

  14. Comparison of arbutamine stress and treadmill exercise thallium-201 SPECT: Hemodynamics, safety profile and diagnostic accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Kiat, H.; Berman, D.S. [Cedars-Sinai Medical Centre, Los Angeles, California, LA (United States)

    1998-02-01

    Full text: Arbutamine (ARB), a new pharmacologic stress agent with enhanced chronotropic property compared to dobutamine, was compared with treadmill (TM) exercise testing (Ex) in a multicenter study using thallium-201 (Tl) SPECT. Of the total of 184 patients who underwent ARB, 69 also had TM stress and quantitative coronary angiography. Fifty-eight patients with a low pretest likelihood of CAD also underwent ARB study for evaluation of test specificity (normalcy rate). Tl scans were scored by a central laboratory using a 20 segment (seg)/scan visual analysis (5 point system: 0=normal, 4-absent uptake). Maximum heart rate (HR) by ARB and Ex was 122 vs 141 bpm (p<0.05). Mean %HR change from baseline was similar (79% vs 82%, respectively, p=ns). Maximum systolic BP for ARB and Ex was 173 vs 175 mmHg, and mean % change from baseline was 24% vs 28% (p=ns). Sensitivity for detecting CAD (270% stenosis) by ARB Tl was 94% and 97% by Ex Tl (p=ns). Stress Tl SPECT segmental agreement for presence of defect between ARB and Ex was 92% (kappa=0.8, p<0.001). Exact segmental stress Tl score (0-4 grading) agreement was 83 % (kappa=0.7, p<0.001). Among 346 segs with stress defects by both ARB and Ex defect reversibility agreement was 86% (kappa=0.7, p<0.001). The normalcy rate for ARB TI-SPECT among patients with a low likelihood of CAD was 90%. Adverse events were mostly mild (tremor: 23%, flushing: 10%, headache: 10%, paraesthesia: 8%, dizziness: 8%, hot flushes: 4%). Arrhythimia of clinical concern occurred in 8% (10/122) of ARB patients who had cardiac catheterisation and in 1.4% (1/69) of patients who had stress Tl. Of all 184 patients with ARB stress, ARB was discontinued due to arrhythmia in 7(5%) and 1 patient had IV Metoprolol for frequent ventricular couplets. Sustained arrhythmias were not observed

  15. Thallium-201 myocardial scintigraphy in patients with normal coronary arteries and normal left ventriculogram. Comparison with hemodynamic, metabolic and morphologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Loesse, B.; Kuhn, H.; Rafflenbeul, D.; Kroenert, H.; Hort, W.; Feinendegen, L.E.; Loogen, F.

    1980-01-01

    36 consecutive patients with chest pain and/or severe ventricular dysrhythmias, but normal coronary arteries and normal left ventriculogram, underwent thallium-201 myocardial imaging at rest and during exercise. The myocardial scintigram was abnormal in 27 patients (group A) and normal in only 9 patients (group B).

  16. The value of quantitative gallium-67 single-photon emission tomography in the clinical management of malignant external otitis

    Energy Technology Data Exchange (ETDEWEB)

    Stokkel, M.P.M.; Eck-Smit, B.L.F. van [Department of Nuclear Medicine and Diagnostic Radiology, Leiden University Hospital (Netherlands); Takes, R.P.; Baatenburg de Jong, R.J. [Department of Otorhinolaryngology and Head and Neck Surgery, Leiden University Hospital (Netherlands)

    1997-11-01

    The objective of this study was to establish whether quantitative gallium-67 single-photon emission tomography (SPET) represents an accurate method for the assessment of infection and, moreover, for the monitoring of therapeutic effect. Eight patients (five males, three females) with the clinical diagnosis of MEO were studied. In three patients antibiotic treatment was prolonged for several weeks because visual analysis of gallium scintigraphy still showed slightly increased uptake in the affected area on the first follow-up scan. In one patient, it was decided to stop antibiotic treatment despite a slight increase in uptake on the second follow-up scan. Lesion to non-lesion (L/NL) ratios obtained from {sup 67}Ga SPET images at initial diagnosis and during follow-up were assessed in correlation with clinical and biochemical data and with the results of CT scans. In addition to a raised erythrocyte sedimentation rate (ESR), all patients showed increased uptake on the affected side, with L/NL ratios ranging from 1.4 to 3.6 at the time of diagnosis. CT scans failed to demonstrate abnormalities in four patients. Including four scans demonstrating slightly increased uptake in the affected area, L/NL ratios after 6-8 weeks of antibiotic treatment were 1.0{+-}0.1. Despite a persistently elevated ESR in the majority of patients, none of them demonstrated local recurrence or complications during follow-up. In all patients, leucocyte count was within the normal range throughout the course. No relation was found between the slightly increased uptake on the follow-up scans and surgical treatment. It is concluded that in addition to the visual analysis of {sup 67}Ga SPET imaging, L/NL ratios should be calculated for a more accurate assessment of disease activity in MEO. Despite visually slightly increased uptake, L/NL ratios of 1.0{+-}0.1 during follow-up are highly indicative of complete recovery, regardless of ESR values or leucocytosis. CT scans are of little value for

  17. Gated single-photon emission computed tomography: the present-day 'one-stop-shop' for cardiac imaging

    Energy Technology Data Exchange (ETDEWEB)

    Sciagra' , R. [Florence Univ., Firenze (Italy). Nuclear Medicine Unit Department of Clinical Physiopathology; Leoncini, M. [Misericordia e Dolce Hospital, Prato (Italy). Division of Cardiology

    2005-03-01

    Gated single-photon emission computed tomography (SPECT) is the current state-of-the-art approach to myocardial perfusion imaging. Initially, major emphasis was given to the improvement in diagnostic accuracy of myocardial perfusion imaging for the detection of coronary artery disease, because the evaluation of wall motion and thickening allows the recognition of attenuation artifacts and increases the observer's confidence. Different processing algorithm's make possible to perform a reproducible and reliable assessment of left ventricular (LV) function, which has been extensively validated against various reference methods. Several articles report the additional value of functional data derived from gated SPECT to increase the accuracy of myocardial perfusion imaging in particular patient groups, such a women, to enhance the detection of multivessel coronary artery disease and to permit the recognition of severe stenosis. An extensive literature indicates that gated SPECT allows a more accurate and reliable prognostic stratification of patients with known coronary artery disease. More recently, the peculiar contribution of gated SPECT in the assessment of myocardial variability has been demonstrated, with the possibility to evaluate in a single myocardial perfusion study the presence of preserved tracer uptake and the amount of contractile reserve through the acquisition of gated SPECT during inotropic stimulation with dobutamine. The most recent advance in the application of gated SPECT is the use of this technique for the reproducible assessment of LV functional changes, at follow-up or during inotropic stimulation, with perfusion data in the background. Various clinical settings, such as assessment of response to medical or re synchronization therapy in dilated or ischemic cardiomyopathy, prediction of outcome in chronic coronary artery disease with LV remodeling, evaluation of different treatment strategies in acute myocardial infarction, could take

  18. Clinical evaluation of reducing acquisition time on single-photon emission computed tomography image quality using proprietary resolution recovery software.

    Science.gov (United States)

    Aldridge, Matthew D; Waddington, Wendy W; Dickson, John C; Prakash, Vineet; Ell, Peter J; Bomanji, Jamshed B

    2013-11-01

    A three-dimensional model-based resolution recovery (RR) reconstruction algorithm that compensates for collimator-detector response, resulting in an improvement in reconstructed spatial resolution and signal-to-noise ratio of single-photon emission computed tomography (SPECT) images, was tested. The software is said to retain image quality even with reduced acquisition time. Clinically, any improvement in patient throughput without loss of quality is to be welcomed. Furthermore, future restrictions in radiotracer supplies may add value to this type of data analysis. The aims of this study were to assess improvement in image quality using the software and to evaluate the potential of performing reduced time acquisitions for bone and parathyroid SPECT applications. Data acquisition was performed using the local standard SPECT/CT protocols for 99mTc-hydroxymethylene diphosphonate bone and 99mTc-methoxyisobutylisonitrile parathyroid SPECT imaging. The principal modification applied was the acquisition of an eight-frame gated data set acquired using an ECG simulator with a fixed signal as the trigger. This had the effect of partitioning the data such that the effect of reduced time acquisitions could be assessed without conferring additional scanning time on the patient. The set of summed data sets was then independently reconstructed using the RR software to permit a blinded assessment of the effect of acquired counts upon reconstructed image quality as adjudged by three experienced observers. Data sets reconstructed with the RR software were compared with the local standard processing protocols; filtered back-projection and ordered-subset expectation-maximization. Thirty SPECT studies were assessed (20 bone and 10 parathyroid). The images reconstructed with the RR algorithm showed improved image quality for both full-time and half-time acquisitions over local current processing protocols (Pquality compared with local processing protocols and has been introduced into

  19. Superconducting Single Photon Detectors

    NARCIS (Netherlands)

    Dorenbos, S.N.

    2011-01-01

    This thesis is about the development of a detector for single photons, particles of light. New techniques are being developed that require high performance single photon detection, such as quantum cryptography, single molecule detection, optical radar, ballistic imaging, circuit testing and

  20. Single-photon imaging

    CERN Document Server

    Seitz, Peter

    2011-01-01

    The acquisition and interpretation of images is a central capability in almost all scientific and technological domains. In particular, the acquisition of electromagnetic radiation, in the form of visible light, UV, infrared, X-ray, etc. is of enormous practical importance. The ultimate sensitivity in electronic imaging is the detection of individual photons. With this book, the first comprehensive review of all aspects of single-photon electronic imaging has been created. Topics include theoretical basics, semiconductor fabrication, single-photon detection principles, imager design and applications of different spectral domains. Today, the solid-state fabrication capabilities for several types of image sensors has advanced to a point, where uncoooled single-photon electronic imaging will soon become a consumer product. This book is giving a specialist´s view from different domains to the forthcoming “single-photon imaging” revolution. The various aspects of single-photon imaging are treated by internati...

  1. No difference in cardiac event-free survival between positron emission tomography-guided and single-photon emission computed tomography-guided patient management - A prospective, randomized comparison of patients with suspicion of jeopardized myocardium

    NARCIS (Netherlands)

    Siebelink, HMJ; Blanksma, PK; Crijns, HJGM; Bax, JJ; van Boven, AJ; Kingma, T; Piers, DA; Pruim, J; Jager, PL; Vaalburg, W; van der Wall, EE

    OBJECTIVES We sought to prospectively compare nitrogen-13 (N-13)-ammonia/(18)fluorodeoxyglucose ((18)FDG) positron emission tomography (PET)-guided management with stress/rest technetium-99m (Tc-99m)-sestamibi single-photon emission computed tomography (SPECT)-guided management BACKGROUND Patients

  2. Single photon quantum cryptography.

    Science.gov (United States)

    Beveratos, Alexios; Brouri, Rosa; Gacoin, Thierry; Villing, André; Poizat, Jean-Philippe; Grangier, Philippe

    2002-10-28

    We report the full implementation of a quantum cryptography protocol using a stream of single photon pulses generated by a stable and efficient source operating at room temperature. The single photon pulses are emitted on demand by a single nitrogen-vacancy color center in a diamond nanocrystal. The quantum bit error rate is less that 4.6% and the secure bit rate is 7700 bits/s. The overall performances of our system reaches a domain where single photons have a measurable advantage over an equivalent system based on attenuated light pulses.

  3. The distribution of cerebral muscarinic acetylcholine receptors in vivo in patients with dementia. A controlled study with 123IQNB and single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Weinberger, D.R.; Gibson, R.; Coppola, R.; Jones, D.W.; Molchan, S.; Sunderland, T.; Berman, K.F.; Reba, R.C. (National Institute of Mental Health Neuroscience Center, Washington, DC (USA))

    1991-02-01

    A high-affinity muscarinic receptor antagonist, 123IQNB (3-quinuclidinyl-4-iodobenzilate labeled with iodine 123), was used with single photon emission computed tomography to image muscarinic acetylcholine receptors in 14 patients with dementia and in 11 healthy controls. High-resolution single photon emission computed tomographic scanning was performed 21 hours after the intravenous administration of approximately 5 mCi of IQNB. In normal subjects, the images of retained ligand showed a consistent regional pattern that correlated with postmortem studies of the relative distribution of muscarinic receptors in the normal human brain, having high radioactivity counts in the basal ganglia, occipital cortex, and insular cortex, low counts in the thalamus, and virtually no counts in the cerebellum. Eight of 12 patients with a clinical diagnosis of Alzheimer's disease had obvious focal cortical defects in either frontal or posterior temporal cortex. Both patients with a clinical diagnosis of Pick's disease had obvious frontal and anterior temporal defects. A region of interest statistical analysis of relative regional activity revealed a significant reduction bilaterally in the posterior temporal cortex of the patients with Alzheimer's disease compared with controls. This study demonstrates the practicability of acetylcholine receptor imaging with 123IQNB and single photon emission computed tomography. The data suggest that focal abnormalities in muscarinic binding in vivo may characterize some patients with Alzheimer's disease and Pick's disease, but further studies are needed to address questions about partial volume artifacts and receptor quantification.

  4. An Incidentally Found Inflamed Uterine Myoma Causing Low Abdominal Pain, Using Tc-99m-Tektrotyd Single Photon Emission Computed Tomography-CT Hybrid Imaging

    OpenAIRE

    Zandieh, Shahin; Sch?tz, Matthias; Bernt, Reinhard; Zwerina, Jochen; Haller, Joerg

    2013-01-01

    We report the case of a 50-year-old woman presented with a history of right hemicolectomy due to an ileocecal neuroendocrine tumor and left breast metastasis. Owing to a slightly elevated chromogranin A-level and lower abdominal pain, single photon emission computed tomography-computer tomography (SPECT-CT) was performed. There were no signs of recurrence on the SPECT-CT scan, but the patient was incidentally found to have an inflamed intramural myoma. We believe that the slightly elevated ch...

  5. Benzodiazepine receptor equilibrium constants for flumazenil and midazolam determined in humans with the single photon emission computer tomography tracer [123I]iomazenil

    DEFF Research Database (Denmark)

    Videbaek, C; Friberg, L; Holm, S

    1993-01-01

    This study is based on the steady state method for the calculation of Kd values recently described by Lassen (J. Cereb. Blood Flow Metab. 12 (1992), 709), in which a constant infusion of the examined nonradioactive ligand is used with a bolus injection of tracer. Eight volunteers were examined...... twice, once without receptor blockade and once with a constant degree of partial blockade of the benzodiazepine receptors by infusion of nonradioactive flumazenil (Lanexat) or midazolam (Dormicum). Single photon emission computer tomography and blood sampling were performed intermittently for 6 h after...

  6. Association of Novelty Seeking Scores and Striatal Dopamine D2/D3 Receptor Availability of Healthy Volunteers: Single Photon Emission Computed Tomography With 123I-iodobenzamide

    Directory of Open Access Journals (Sweden)

    Hsiang Yu Huang

    2010-10-01

    Full Text Available It has been speculated that novelty seeking (NS behavior is related to the dopaminergic system. Fifty-two subjects completed the Tridimensional Personality Questionnaire and underwent single photon emission computed tomography with 123I-iodobenzamide. A marginally positive correlation was noted between NS and striatal dopamine D2/D3 receptor availability (r = 0.25, p =0.07. A positive association was noted between the NS scores and left striatal D2/D3 receptor availability (r= 0.29, p =0.04. The results suggest that a relationship might exist between NS score and dopaminergic activity.

  7. Enhanced single photon emission from positioned InP/GaInP quantum dots coupled to a confined Tamm-plasmon mode

    Energy Technology Data Exchange (ETDEWEB)

    Braun, T.; Baumann, V.; Iff, O.; Schneider, C.; Kamp, M. [Technische Physik, Physikalisches Institut and Wilhelm Conrad Röntgen-Research Center for Complex Material Systems, Universität Würzburg, Am Hubland, D-97074 Würzburg (Germany); Höfling, S. [Technische Physik, Physikalisches Institut and Wilhelm Conrad Röntgen-Research Center for Complex Material Systems, Universität Würzburg, Am Hubland, D-97074 Würzburg (Germany); SUPA, School of Physics and Astronomy, University of St Andrews, St Andrews KY16 9SS (United Kingdom)

    2015-01-26

    We report on the enhancement of the spontaneous emission in the visible red spectral range from site-controlled InP/GaInP quantum dots by resonant coupling to Tamm-plasmon modes confined beneath gold disks in a hybrid metal/semiconductor structure. The enhancement of the emission intensity is confirmed by spatially resolved micro-photoluminescence area scans and temperature dependent measurements. Single photon emission from our coupled system is verified via second order autocorrelation measurements. We observe bright single quantum dot emission of up to ∼173 000 detected photons per second at a repetition rate of the excitation source of 82 MHz, and calculate an extraction efficiency of our device as high as 7%.

  8. Triggered single photon emission up to 77K from ordered array of surface curvature-directed mesa-top GaAs/InGaAs single quantum dots.

    Science.gov (United States)

    Zhang, Jiefei; Lu, Siyuan; Chattaraj, Swarnabha; Madhukar, Anupam

    2016-12-26

    We demonstrate triggered single photon emission up to 77K from an ordered 5x8 array of InGaAs single quantum dots (SQDs). The SQDs are grown selectively on patterned mesa tops utilizing substrate-encoded size-reducing epitaxy (SESRE). It exploits designed surface-curvature stress gradients to preferentially direct atom migration from mesa sidewalls to the top during growth. The emission from the SQDs exhibits a g(2)(0) of 0.19 ± 0.03 at 8K and decent emission spectral uniformity (standard deviation <1% of emission wavelength). The SESRE QDs are inherently compatible with on-chip integrated light manipulation elements, thereby enabling a path towards integrated nanophotonic systems for quantum information processing.

  9. Regional cerebral blood flow single photon emission computed tomography for detection of Frontotemporal dementia in people with suspected dementia.

    Science.gov (United States)

    Archer, Hilary A; Smailagic, Nadja; John, Christeena; Holmes, Robin B; Takwoingi, Yemisi; Coulthard, Elizabeth J; Cullum, Sarah

    2015-06-23

    In the UK, dementia affects 5% of the population aged over 65 years and 25% of those over 85 years. Frontotemporal dementia (FTD) represents one subtype and is thought to account for up to 16% of all degenerative dementias. Although the core of the diagnostic process in dementia rests firmly on clinical and cognitive assessments, a wide range of investigations are available to aid diagnosis.Regional cerebral blood flow (rCBF) single-photon emission computed tomography (SPECT) is an established clinical tool that uses an intravenously injected radiolabelled tracer to map blood flow in the brain. In FTD the characteristic pattern seen is hypoperfusion of the frontal and anterior temporal lobes. This pattern of blood flow is different to patterns seen in other subtypes of dementia and so can be used to differentiate FTD.It has been proposed that a diagnosis of FTD, (particularly early stage), should be made not only on the basis of clinical criteria but using a combination of other diagnostic findings, including rCBF SPECT. However, more extensive testing comes at a financial cost, and with a potential risk to patient safety and comfort. To determine the diagnostic accuracy of rCBF SPECT for diagnosing FTD in populations with suspected dementia in secondary/tertiary healthcare settings and in the differential diagnosis of FTD from other dementia subtypes. Our search strategy used two concepts: (a) the index test and (b) the condition of interest. We searched citation databases, including MEDLINE (Ovid SP), EMBASE (Ovid SP), BIOSIS (Ovid SP), Web of Science Core Collection (ISI Web of Science), PsycINFO (Ovid SP), CINAHL (EBSCOhost) and LILACS (Bireme), using structured search strategies appropriate for each database. In addition we searched specialised sources of diagnostic test accuracy studies and reviews including: MEDION (Universities of Maastricht and Leuven), DARE (Database of Abstracts of Reviews of Effects) and HTA (Health Technology Assessment) database

  10. Emission of single photons, hadrons, and dileptons in $Pb+Pb$ collisions at CERN SPS and quark hadron phase transition

    CERN Document Server

    Srivastava, D K; Kvasnikova, I; Gale, C; Srivastava, Dinesh Kumar; Sinha, Bikash; Kvasnikova, Ioulia; Gale, Charles

    2002-01-01

    The production of single photons in $Pb+Pb$ collisions at the CERN SPS as measured by the WA98 experiment is analysed. A very good description of the data is obtained if a quark gluon plasma is assumed to be formed initially, which expands, cools, hadronizes, and undergoes freeze-out. A rich hadronic equation of state is used and the transverse expansion of the interacting system is taken into account. The recent estimates of photon production in quark-matter (at two loop level) along with the dominant reactions in the hadronic matter leading to photons are used. Most of the radiation of the photons is seen to arise from the quark-matter, which contributes dominantly through the mechanism of annihilation of quarks with scattering, and which in turn is possible only in a hot and dense plasma of quarks and gluons. The same treatment provides a very good description to hadronic spectra measured by several groups and the intermediate mass dileptons measured by the NA50 experiment, lending a strong support to the ...

  11. Absolute quantitation of iodine-123 epidepride kinetics using single-photon emission tomography: comparison with carbon-11 epidepride and positron emission tomography.

    Science.gov (United States)

    Almeida, P; Ribeiro, M J; Bottlaender, M; Loc'h, C; Langer, O; Strul, D; Hugonnard, P; Grangeat, P; Mazière, B; Bendriem, B

    1999-12-01

    Epidepride labelled with iodine-123 is a suitable probe for the in vivo imaging of striatal and extrastriatal dopamine D2 receptors using single-photon emission tomography (SPET). Recently, this molecule has also been labelled with carbon-11. The goal of this work was to develop a method allowing the in vivo quantification of radioactivity uptake in baboon brain using SPET and to validate it using positron emission tomography (PET). SPET studies were performed in Papio anubis baboons using 123I-epidepride. Emission and transmission measurements were acquired on a dual-headed system with variable head angulation and low-energy ultra-high resolution (LEUHR) collimation. The imaging protocol consisted of one transmission measurement (24 min, heads at 90 degrees), obtained with two sliding line sources of gadolinium-153 prior to injection of 0.21-0.46 GBq of 123I-epidepride, and 12 emission measurements starting 5 min post injection. For scatter correction (SC) we used a dual-window method adapted to 123I. Collimator blurring correction (CBC) was done by deconvolution in Fourier space and attenuation correction (AT) was applied on a preliminary (CBC) filtered back-projection reconstruction using 12 iterations of a preconditioned, regularized minimal residual algorithm. For each reconstruction, a calibration factor was derived from a uniform cylinder filled with a 123I solution of a known radioactivity concentration. Calibration and baboon images were systematically built with the same reconstruction parameters. Uncorrected (UNC) and (AT), (SC + AT) and (SC + CBC + AT) corrected images were compared. PET acquisitions using 0.11-0.44 GBq of 11C-epidepride were performed on the same baboons and used as a reference. The radioactive concentrations expressed in percent of the injected dose per 100 ml (% ID/100 ml) obtained after (SC + CBC + AT) in SPET are in good agreement with those obtained with PET and 11C-epidepride. A method for the in vivo absolute quantitation of 123

  12. Initial experience with single-photon emission tomography using iodine-123-labelled 2[beta]-carbomethoxy-3[beta](4-iodophnyl)tropane in human brain

    Energy Technology Data Exchange (ETDEWEB)

    Kuikka, J.T. (Kuopio Univ. Hospital (Finland). Dept. of Clinical Physiology); Bergstroem, K.A. (Kuopio Univ. Hospital (Finland). Dept. of Clinical Physiology); Vanninen, E. (Kuopio Univ. Hospital (Finland). Dept. of Clinical Physiology); Laulumaa, V. (Kuopio Univ. Hospital (Finland). Dept. of Neurology); Hartikainen, P. (Kuopio Univ. Hospital (Finland). Dept. of Neurology); Laensimies, E. (Kuopio Univ. Hospital (Finland). Dept. of Clinical Physiology)

    1993-09-01

    The iodinated cocaine analogue 2[beta]-carbomethoxy-3[beta]-(4-iodophenyl)tropane ([sup 123]I[beta]-CIT), a new dopamine transporter, was preliminarily tested in human brain. Two normal volunteers and two patients with Parkinson's disease were imaged with a high-resolution single-photon emission tomography scanner. The specific binding of [sup 123]I[beta]-CIT in the basal ganglia and thalamus was high in normal volunteers. In addition, there was relatively intense uptake in the medial prefrontal area. Patients with Parkinson's disease who were older than controls showed significantly lower specific binding in the basal ganglia and thalamus and no uptake in the medial prefrontal cortex. This decrease in the dopamine transporter may be age related. (orig.)

  13. An incidentally found inflamed uterine myoma causing low abdominal pain, using Tc-99m-tektrotyd single photon emission computed tomography-CT hybrid imaging.

    Science.gov (United States)

    Zandieh, Shahin; Schütz, Matthias; Bernt, Reinhard; Zwerina, Jochen; Haller, Joerg

    2013-01-01

    We report the case of a 50-year-old woman presented with a history of right hemicolectomy due to an ileocecal neuroendocrine tumor and left breast metastasis. Owing to a slightly elevated chromogranin A-level and lower abdominal pain, single photon emission computed tomography-computer tomography (SPECT-CT) was performed. There were no signs of recurrence on the SPECT-CT scan, but the patient was incidentally found to have an inflamed intramural myoma. We believe that the slightly elevated chromogranin A-level was caused by the hypertension that the patient presented. In the clinical context, this is a report of an inflamed uterine myoma seen as a false positive result detected by TC-99m-Tc-EDDA/HYNIC-Tyr3-Octreotide (Tektrotyd) SPECT-CT hybrid imaging.

  14. An incidentally found inflamed uterine myoma Causing low abdominal pain, using TC-99m-tektrotyd single photon emission computed tomography-CT hybrid imaging

    Energy Technology Data Exchange (ETDEWEB)

    Zandieh, Shahin; Schuetz, Matthias; Bernt, Reinhard; Zwerina, Jochen; Haller, Joerg [Hanusch-Hospital, Teaching Hospital of Medical University of Vienna, Vienna (Australia)

    2013-10-15

    We report the case of a 50-year-old woman presented with a history of right hemicolectomy due to an ileocecal neuroendocrine tumor and left breast metastasis. Owing to a slightly elevated chromogranin A-level and lower abdominal pain, single photon emission computed tomography-computer tomography (SPECT-CT) was performed. There were no signs of recurrence on the SPECT-CT scan, but the patient was incidentally found to have an inflamed intramural myoma. We believe that the slightly elevated chromogranin A-level was caused by the hypertension that the patient presented. In the clinical context, this is a report of an inflamed uterine myoma seen as a false positive result detected by TC-99m-Tc-EDDA/HYNIC-Tyr3-Octreotide (Tektrotyd) SPECT-CT hybrid imaging.

  15. Single photon emission computed tomography of technetium-99m tetrofosmin myocardial perfusion imaging in patients with systemic lupus erythematosus-A preliminary report

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Jen-Jhy; Hsu, Hsiu-Bao; Sun, Shung-Shung; Kao, Chia-Hung [China Medical Coll., Taichung, Taiwan (China). Hospital; Wang, Jhi-Joung [Chi-Mei Medical Center, Tainan, Taiwan (China); Ho, Shung-Tai [National Defense Medical Center, Taipei, Taiwan (China). School of Medicine

    2003-01-01

    The purpose of this study was to evaluate the utility of single-photon emission computed tomography (SPECT) of technetium-99m tetrofosmin (Tc-99m TF) myocardial perfusion imaging to detect myocardial involvement in patients with systemic lupus erythematosus (SLE). Three groups of subjects-group 1: 25 SLE female patients with non-specific cardiac symptoms and signs, group 2: 25 female SLE patients without any cardiac symptoms and signs, and group 3: 25 female healthy controls-were evaluated by comparing rest and dipyridamole-stress Tc-99m TF myocardial perfusion SPECT. Tc-99m TF myocardial perfusion SPECT revealed perfusion defects in 88% and 40% of the cases in groups 1 and 2, respectively. However, no cases in group 3 demonstrated myocardial perfusion defects. Tc-99m TF myocardial perfusion SPECT is a useful noninvasive imaging modality to detect cardiac involvement in SLE patients with or without cardiac symptoms and signs. (author)

  16. Acute effect of electroconvulsive therapy on brain perfusion assessed by Tc99m-hexamethylpropyleneamineoxim and single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Bajc, M.; Basic, M.; Topuzovic, N.; Babic, D.; Ivancevic, D. (Department of Nuclear Medicine, University Hospital Rebro, Zagreb (Yugoslavia)); Medved, V. (Psychiatric Clinic, University Hospital Rebro, Zagreb (Yugoslavia))

    1989-01-01

    Regional cerebral blood flow (rCBF) was measured in relative terms with Tc99m-hexamethylpropyleneamineoxim and single photon emission computed tomography in 11 patients undergoing electroconvulsive therapy (ECT). The patients suffered from major depressive disorder (n=8) or schizoaffective disorders (n=3). rCBF was measured under general anesthesia 3 days prior to the ECT treatment and coinciding with the ECT stimualtion. ECT caused a redistribution of the tracers uptake. The uptake became more pronounced in frontal parts of the brain and in the basal ganglia than in posterior parts of the cortex, and the thalamus. This selective effect of ECT on rCBF may be related to catecholaminergic projections to anterior parts of the brain. (author).

  17. Clinical Value of Perfusion Abnormalities of Brain on Technetium-99m HMPAO Single-Photon Emission Computed Tomography in Children With Sydenham Chorea.

    Science.gov (United States)

    Giorgio, Sara Maria Delle Acque; Caprio, Maria Grazia; Galante, Flavia; Russo, Giustina; Romano, Alfonso; Vergara, Emilia; Alessio, Maria; Cuocolo, Alberto

    2017-03-01

    We evaluated whether perfusion brain abnormalities by single-photon emission computed tomography (SPECT) imaging improves diagnostic and prognostic assessment in Sydenham chorea. Twenty-three children with acute autoimmune chorea underwent technetium-99m hexamethylpropyleneamine oxime brain SPECT imaging. In 16 children, SPECT was repeated during the follow-up. A pattern of basal ganglia hyperperfusion was observed in 20 (87%) patients. In 4 of 10 patients with generalized chorea, perfusion was comparable in right and left striatum and right and left thalamus. In 13 patients with hemi-chorea and in 3 with generalized chorea, unilateral hyperperfusion was detected. Three patients with generalized chorea had normal perfusion. Tracer uptake of basal ganglia of the patients at the acute phase was higher than at the follow-up ( P < .001). SPECT seems a useful noninvasive tool in pediatric patients with Sydenham chorea to support the clinicians during the acute phase of disease and to monitor the course of autoimmune chorea.

  18. Regional cerebral blood flow in senile dementia of Alzheimer's type and multiple infarct dementia. Study with Xe-133 single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kawakatsu, Shinobu; Shinohara, Masao; Morinobu, Shigeru

    1987-12-01

    Single photon emission computed tomography (SPECT) with Xe-133 inhalation method was undertaken in 13 patients with mild or moderate senile dementia of Alzheimer's type (SDAT), 9 patients with multiple infarct demantia (MID), and 7 normal controls. Mean blood flow of the hemisphere was significantly decreased in both SDAT and MID groups than the control group. The decreased blood flow was correlated with the severity of SDAT, but not with MID. Regional cerebral blood flow (rCBF) of the SDAT group was significantly decreased in moderate cases than the control group, especially in the bilateral perietal areas, although this did not differ in the mild SDAT cases and the control cases. For MID, rCBF was significantly decreased in the bilateral frontal, basal nucleus, and left lateral areas. The findings led to the conclusion that SPECT is useful in the differential diagnosis of dementia and elucidation of the pathogenesis. (Namekawa, K.).

  19. Hybrid Single-Photon Emission Computed Tomography/Computed Tomography Imaging Features of Tumoral Calcinosis in Technetium-99m Methylene Diphosphonate Bone Scintigraphy.

    Science.gov (United States)

    Kamaleshwaran, Koramadai Karuppusamy; Asokumar, Premkumar; Malaikkal, Anjali; Mohanan, Vyshakh; Shinto, Ajit Sugunan

    2015-01-01

    Tumoral calcinosis (TC) is an uncommon ectopic calcification syndrome. TC is a benign condition characterized by the presence of large calcific soft tissue deposits occurring predominantly in a periarticular location. It generally occurs as a complication of renal dialysis or trauma, and is rarely seen in familial and sporadic cases. Bone scintigraphy is a sensitive method for diagnosing TC. We report a case of year old female with. She underwent bone scintigraphy to see the sites of involvement, which showed intense foci of tracer activity in soft tissue in bilateral thigh and gluteal region. Hybrid single-photon emission computed tomography/computed tomography of the pelvis and thigh localized tracer uptake to the calcification in the gluteal and thigh region.

  20. Detection and dosimetry of gamma ray emitted from thallium-201 and technetium-99m based on chemiluminescence technique

    Energy Technology Data Exchange (ETDEWEB)

    Shourian, Mostafa [Laboratory of Microanalysis, Institute of Biochemistry and Biophysics, University of Tehran, P.O. Box 13145-1384, Tehran (Iran, Islamic Republic of); Tavakoli, Hassan, E-mail: tavakoli@ibb.ut.ac.i [Faculty of Medicine, Department of Physiology and Biophysics, Faculty of Medicine, Baqiyatollah University of Medical Sciences, P.O. Box 19395-6558, Tehran (Iran, Islamic Republic of); Ghourchian, Hedayatollah, E-mail: hadi@ibb.ut.ac.i [Laboratory of Microanalysis, Institute of Biochemistry and Biophysics, University of Tehran, P.O. Box 13145-1384, Tehran (Iran, Islamic Republic of); Rafiee-Pour, Hossain-Ali [Laboratory of Microanalysis, Institute of Biochemistry and Biophysics, University of Tehran, P.O. Box 13145-1384, Tehran (Iran, Islamic Republic of)

    2010-09-15

    This report describes the detection and dosimetry of gamma ray emitted from Thallium-201 ({sup 201}Tl) and Technetium-99m ({sup 99m}Tc) based on chemiluminescence technique. H{sub 2}O{sub 2} produced by two gamma emitter radioisotopes of {sup 201}Tl and {sup 99m}Tc were quantitatively measured by chemiluminescence method. Upon producing H{sub 2}O{sub 2} in a luminol alkaline solution, in the presence of diperiodatocuprate, as catalyst a chemical reaction was accrued and consequently the emitted light was measured. The determined H{sub 2}O{sub 2} concentration was correlated with the gamma ray detection and dosimetry. The sensitivity of chemiluminescence technique for {sup 201}Tl and {sup 99m}Tc dosimetry was determined to be 0.20 and 0.08 MBq/l (Mega Becquerel per liter) respectively (R.S.D. = %5, N = 3). The plotted calibration curves showed detection limits of 3.24 and 1.76 MBq/l for {sup 201}Tl and {sup 99m}Tc, respectively.

  1. Myocardial infarction diagnosis with body surface potential mapping, electrocardiography, vectorcardiography and thallium-201 scintigraphy: a correlative study with left ventriculography.

    Science.gov (United States)

    Ackaoui, A; Nadeau, R; Sestier, F; Savard, P; Primeau, R; Lemieux, R; Descary, M C

    1985-01-01

    In 35 subjects with typical or atypical angina and/or documented myocardial infarction (MI), body surface potential maps (BSPMs), ECG, VCG and rest Thallium-201 (T1-201) have been compared to left ventriculography (LVG). BSPMs were recorded with 26 ECGs, and BSPM abnormalities for MI cases were considered to be areas of normally positive potentials that have become negative. Subjects with MI were classified according to the segmental localization and degree of asynergy on LVG. Moderate anterolateral and apical asynergy were found to correlate with BSPM diagnosis of anterolateral MI and ischemia, severe anterolateral and apical asynergy with BSPM diagnosis of anterolateral MI and ischemia, and moderate diaphragmatic and/or posterobasal asynergy with BSPM diagnosis of posterior MI. Simultaneous anterior and posterior asynergy were found for BSPM diagnosis of anterior with posterior MI. Subjects with no LVG asynergy had normal BSPMs. BSPM diagnosis had the highest correlation coefficient with the LVG diagnosis (r = 0.88). ECG and VCG showed similar results with r = 0.65 and 0.71 respectively, while T1-201 had r = 0.55. The examination of our BSPMs, as well as the ECG, VCG and T1-201, did not permit to detect apical damage in presence of anterior MI, and posterobasal damage in the presence of inferoposterior MI. It is concluded that BSPMs are slightly superior to ECG and VCG for diagnosis of MI.

  2. High-resolution nuclear magnetic resonance imaging and single photon emission computerized tomography--cerebral blood flow in a case of pure sensory stroke and mild dementia owing to subcortical arteriosclerotic encephalopathy (Binswanger's disease)

    DEFF Research Database (Denmark)

    De Chiara, S; Lassen, N A; Andersen, A R

    1987-01-01

    involving visiospatial apraxia; this pointed to decreased function of the right parietal cortex, which was structurally intact on CT and NMRI. Single photon emission computerized tomography by Xenon-133 injection and by hexamethyl-propyleneamine-oxim labeled with Technetium-99m showed asymmetric...

  3. Comparison of Tc-99m-sestamibi-F-18-fluorodeoxyglucose dual isotope simultaneous acquisition and rest-stress Tc-99m-sestamibi single photon emission computed tomography for the assessment of myocardial viability

    NARCIS (Netherlands)

    De Boer, J; Slart, RHJA; Blanksma, Paulus; Willemsen, ATM; Jager, PL; Paans, AMJ; Vaalburg, W; Piers, DA

    Dual isotope simultaneous acquisition single photon emission computed tomography (DISA SPECT) offers the advantage of obtaining information on myocardial perfusion using Tc-99m-sestamibi (Tc-99m-MIBI) and metabolism using F-18-fluorodeoxyglucose (F-18-FDG) in a single study. The prerequisite is that

  4. Comparison of 99mTc-sestamibi-18F-fluorodeoxyglucose dual isotope simultaneous acquisition and rest-stress 99mTc-sestamibi single photon emission computed tomography for the assessment of myocardial viability

    NARCIS (Netherlands)

    den Boer, Johan; Slart, R H J A; Blanksma, P K; Willemsen, Antonius; Jager, P L; Paans, A M J; Vaalburg, W; Piers, D A

    Dual isotope simultaneous acquisition single photon emission computed tomography (DISA SPECT) offers the advantage of obtaining information on myocardial perfusion using Tc-sestamibi ( Tc-MIBI) and metabolism using F-fluorodeoxyglucose ( F-FDG) in a single study. The prerequisite is that the Tc-MIBI

  5. Monoamine oxidase B single-photon emission tomography with [{sup 123}I]Ro 43-0463: imaging in volunteers and patients with temporal lobe epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Buck, A. [Division of Nuclear Medicine, University Hospital Zurich (Switzerland); Frey, L.D. [Department of Nuclear Medicine, Kantonsspital Aarau (Switzerland); Blaeuenstein, P.; Schubiger, P. [Paul Scherrer Institut, Radiopharmacy Division, Villigen (Switzerland); Kraemer, G. [Swiss Epilepsy Clinic, Zurich (Switzerland); Siegel, A.; Weber, B.; Wieser, H.G. [Department of Neurology, University Hospital Zurich (Switzerland)

    1998-05-01

    Imaging of monoamine oxidase of subtype B (MAO B) is of interest in various neurological diseases. In the past non-invasive assessment of MAO B has only been possible with positron emission tomography (PET) ligands. Given the limited availability of PET, a single-photon emission tomography (SPET) ligand would be desirable. In this study SPET imaging with the new MAO B inhibitor [{sup 123}I]Ro 43-0463 was performed in five volunteers and nine patients with temporal lobe epilepsy (TLE). In two volunteers a second study was performed 12 h following blockade with deprenyl. In the TLE patients the tracer was administered as bolus (n = 4) or as prolonged infusion (n = 5). The regional uptake pattern correlated well with the known distribution of MAO B. In the two blocking studies ligand uptake was substantially reduced compared with baseline. In the TLE patients increased uptake was found in the ipsilateral mesial temporal lobe and, surprisingly, in the ipsilateral putamen. This study indicates the potential of the new SPET ligand [{sup 123}I]Ro 43-0463 to map MAO B concentration in the human brain. The new finding of increased MAO B in the putamen of TLE patients needs further studies to elucidate its exact pathophysiology. (orig.) With 3 figs., 3 tabs., 28 refs.

  6. Functional Significance of Angiographic Collaterals in Patients with Totally Occluded Right Coronary Artery: Intracoronary Thallium-201 Scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Yun; Lee, Jong Doo; Cho, Seung Yun; Shim, Won Heum; Ha, Jong Won; Kim, Han Soo; Kwon, Hyuk Moon; Jang, Yang Soo; Chung, Nam Sik; Kim, Sung Soon [Yonsei University College of Medicine, Seoul (Korea, Republic of); Park, Chang Yun; Kim, Young Soo [Inje University College of Medicine, Seoul (Korea, Republic of)

    1993-07-15

    To compare the myocardial viability in patients suffering from total occlusion of the right coronary artery (RCA) with the angiographic collaterals, intracoronary injection of Thallium-201 (T1-201) was done to 14 coronary artery disease (CAD) patients (pts) with total occlusion of RCA and into four normal subjects for control. All 14 CAD pts had Grade 2 or 3 collateral circulations. There were 14 male and 4 females, and their ages ranged from 31 to 70 years. In nine pts, T1-201 was injected into left main coronary artery (LCA) (300 approx 350 mu Ci) to evaluate the myocardial viability of RCA territory through collateral circulations. The remaining five pts received T1-201 into RCA (200-250 mu Ci) because two had intraarterial bridging collaterals and three had previous successful PTCA. Planar and SPECT myocardial perfusion images were obtained 30 minutes, and four to five hours after T1-201 reinjection. Intravenous T1-201 reinjection (six pts) or {sup 99m}Tc-MIBI (two pts) were also performed in eight CAD pts. Intracoronary myocardial perfusion images were compared with intravenous T1-201(IV T1-201) images, EGG, and ventriculography. Intracoronary TI-201 images proved to be superior to that of IV T1-201 due to better myocardial to background uptake ratio and more effective in the detection of viable tissue. We also found that perfusion defects were smaller on intracoronary T1-201 images than those on the IV T1-201. All of the 14 CAD pts had either mostly viable myocardium (seven pts) or large area of T1-201 perfusion (seven pts) in RCA territory, however ventriculographic wall motion and ECG did not correlate well with intracoronary myocardial perfusion images. In conclusion, total RCA occlusion patients with well developed collateral circulation had large area of viable myocardial in the corresponding territory.

  7. Disease stage classification in hypertrophic cardiomyopathy by dual analysis of iodine-123-labeled metaiodobenzylguanidine and thallium-201 myocardial scintigraphies

    Energy Technology Data Exchange (ETDEWEB)

    Hiasa, Go [Ehime Univ., Matsuyama (Japan). School of Medicine

    2001-08-01

    Many patients with hypertrophic cardiomyopathy (HCM) gradually changes from typical myocardial hypertrophy to dilated cardiomyopathy-like features. However, it is difficult to estimate the disease stage in HCM. To determine the disease stage, dual analysis of iodine-123-labeled metaiodobenzylguanidine ({sup 123}I-MIBG) and thallium-201 ({sup 201}Tl) myocardial scintigraphies were performed in 108 HCM patients. According to the scintigraphic distribution patterns, patients were divided into three groups. Group A (n=15): normal distributions of both {sup 123}I-MIBG and {sup 201}Tl, group B (n=71): normal {sup 201}Tl and low {sup 123}I-MIBG patterns, group C (n=22): low distributions of both scintigraphies. The decrease in {sup 201}Tl uptake was observed in only group C. Concerning {sup 123}I-MIBG, heart-to-mediastinum ratio (H/M) and washout rate (WOR) had good correlations with left ventricular systolic functions. H/M was decreased and WOR was increased in order of C, B and A groups. Left ventricular diastolic function reflected by isovolumic relaxation time was longer in group B than in group A. Attenuated left ventricular hypertrophy, enlarged left ventricular volumes, impaired left ventricular functions and serious clinical symptoms were observed in only group C. Myocardial sympathetic abnormalities in group B may be mainly due to myocardial hypertrophy, and those in group C may be due to myocardial injury. Dual analysis of {sup 123}I-MIBG and {sup 201}Tl scintigraphies may be useful to classify disease stages of HCM. (author)

  8. Diagnostic value of 123I-phenylpentadecanoic acid (IPPA) metabolic and thallium 201 perfusion imaging in stable coronary artery disease.

    Science.gov (United States)

    Walamies, M; Turjanmaa, V; Koskinen, M; Uusitalo, A

    1993-08-01

    The diagnostic value of 123I-phenylpentadecanoic acid (IPPA) metabolic cardiac imaging was studied in a group (n = 29) of patients with angiographically confirmed CAD using single photon emission computed tomography (SPECT). A symptom-limited exercise test was first done with IPPA, and 2 days later with thallium. Medications were not withheld during testing. Fourteen healthy control subjects participated in parallel IPPA and 15 in thallium tests. Data acquisition and output were comparable in the two imaging modalities. By testing various relatively simple criteria for abnormality we found that the semiquantitative interpretation was more accurate than the visual readings. The best compromise of accuracy with the scored criteria consisted of a sensitivity of 86% and a specificity of 86%, obtained with IPPA polar tomograms (mild exercise defect) and a sensitivity of 86% and a specificity of 80% obtained with thallium (regionally decreased washout). With visual interpretation alone, a sensitivity of 83% and a specificity of 71% was detected with IPPA (mild exercise defect) and 72% and 73%, respectively, with thallium (partial reversibility). The sensitivity of the exercise ECG alone was 62%. The results of this study imply that IPPA imaging could be a rational, uncomplicated clinical method for non-invasive diagnosis of CAD. The diagnostic ability of IPPA is at least as good as that of thallium, and it is possible to use them in succession.

  9. Microscopic theory of indistinguishable single-photon emission from a quantum dot coupled to a cavity: The role of non-Markovian phonon-induced decoherence

    DEFF Research Database (Denmark)

    Nielsen, Per Kær; Lodahl, Peter; Jauho, Antti-Pekka

    2013-01-01

    We study the fundamental limit on single-photon indistinguishability imposed by decoherence due to phonon interactions in semiconductor quantum dot-cavity quantum electrodynamics systems. Employing an exact diagonalization approach we find large differences compared to standard methods. An import......We study the fundamental limit on single-photon indistinguishability imposed by decoherence due to phonon interactions in semiconductor quantum dot-cavity quantum electrodynamics systems. Employing an exact diagonalization approach we find large differences compared to standard methods...

  10. Use of single photon emission computed tomography and magnetic resonance to evaluate central nervous system involvement in patients with juvenile systemic lupus erythematosus

    Directory of Open Access Journals (Sweden)

    Prismich G.

    2002-01-01

    Full Text Available The objective of the present study was to identify the single photon emission computed tomography (SPECT and magnetic resonance (MR findings in juvenile systemic lupus erythematosus (JSLE patients with CNS involvement and to try to correlate them with neurological clinical history data and neurological clinical examination. Nineteen patients with JSLE (16 girls and 3 boys, mean age at onset 9.2 years were submitted to neurological examination, electroencephalography, cerebrospinal fluid analysis, SPECT and MR. All the evaluations were made separately within a period of 15 days. SPECT and MR findings were analyzed independently by two radiologists. Electroencephalography and cerebrospinal fluid analysis revealed no relevant alterations. Ten of 19 patients (53% presented neurological abnormalities including present or past neurological clinical history (8/19, 42%, abnormal neurological clinical examination (5/19, 26%, and abnormal SPECT or MR (8/19, 42% and 3/19, 16%, respectively. The most common changes in SPECT were cerebral hypoperfusion and heterogeneous distribution of blood flow. The most common abnormalities in MR were leukomalacia and diffuse alterations of white matter. There was a correlation between SPECT and MR (P<0.05. We conclude that SPECT and MR are complementary and useful exams in the evaluation of neurological involvement of lupus.

  11. Single photon emission computed tomography (SPECT) findings using N-isopropyl-p-[[sup 123]I]iodoamphetamine ([sup 123]I-IMP) in schizophrenia and atypical psychosis

    Energy Technology Data Exchange (ETDEWEB)

    Suga, Hidemichi (Aichi Medical Univ., Nagakute (Japan))

    1993-05-01

    Sixteen schizophrenic patients, 16 atypical psychosis patients, and 16 healthy volunteers were subjected to single photon emission computed tomography (SPECT) of the brain using N-isopropyl-p-[[sup 123]I]iodoamphetamine ([sup 123]I-IMP). The basal ganglia region was in particular examined not only in transverse sections, but in coronal sections. Schizophrenics showed significantly decreased uptake rates in the bilateral frontal regions and increased uptakes in the bilateral basal ganglia. On the other hand, atypical psychotics had a reduced uptake rate only in the right thalamic region, compared to the controls. The increased uptake rates in the basal ganglia were associated with auditory hallucination, but gender difference, duration of illness and dose of neuroleptics had no influence on these SPECT findings. The results suggest that schizophrenics might have some lesions in the frontal area of the brain, whereas atypical psychotics might have no lesion in the frontal region but dysfunction in the right thalamic region. Subsequently, using only SPECT findings, all the cases were divided by cluster analysis into 4 groups and a residue group. Schizophrenics distributed mainly in the 2 groups that have lesion in the frontal regions. Atypical psychotics distributed principally in the other 2 groups that have alterations in the bilateral thalamic region. The present study suggests that schizophrenia and atypical psychosis might have different etiologies. (author).

  12. Iodine-123 metaiodobenzylguanidine scintigraphy and iodine-123 ioflupane single photon emission computed tomography in Lewy body diseases: complementary or alternative techniques?

    Science.gov (United States)

    Treglia, Giorgio; Cason, Ernesto; Cortelli, Pietro; Gabellini, Anna; Liguori, Rocco; Bagnato, Antonio; Giordano, Alessandro; Fagioli, Giorgio

    2014-01-01

    To compare myocardial sympathetic imaging using (123)I-Metaiodobenzylguanidine (MIBG) scintigraphy and striatal dopaminergic imaging using (123)I-Ioflupane (FP-CIT) single photon emission computed tomography (SPECT) in patients with suspected Lewy body diseases (LBD). Ninety-nine patients who performed both methods within 2 months for differential diagnosis between Parkinson's disease (PD) and other parkinsonism (n = 68) or between dementia with Lewy bodies (DLB) and other dementia (n = 31) were enrolled. Sensitivity, specificity, accuracy, positive and negative predictive values of both methods were calculated. For (123) I-MIBG scintigraphy, the overall sensitivity, specificity, accuracy, positive and negative predictive values in LBD were 83%, 79%, 82%, 86%, and 76%, respectively. For (123)I-FP-CIT SPECT, the overall sensitivity, specificity, accuracy, positive and negative predictive values in LBD were 93%, 41%, 73%, 71%, and 80%, respectively. There was a statistically significant difference between these two methods in patients without LBD, but not in patients with LBD. LBD usually present both myocardial sympathetic and striatal dopaminergic impairments. (123)I-FP-CIT SPECT presents high sensitivity in the diagnosis of LBD; (123)I-MIBG scintigraphy may have a complementary role in differential diagnosis between PD and other parkinsonism. These scintigraphic methods showed similar diagnostic accuracy in differential diagnosis between DLB and other dementia. Copyright © 2012 by the American Society of Neuroimaging.

  13. Technetium-99m hexamethylpropylene amine oxime single photon emission tomography of the brain in early Parkinson's disease: correlation with dementia and lateralization

    Energy Technology Data Exchange (ETDEWEB)

    Wang Shuujiun; Lin Kerneng; Shan Dinge; Liao Kwankum; Fuh Jongling; Lee Liangshong (National Yang-Ming Medical Coll., Taipei (Taiwan)); Liu Renshyan (Veterans General Hospital, Taipei (Taiwan). Dept. of Nuclear Medicine); Liu Hsiuchih (Veterans General Hospital, Taipei (Taiwan). Neurological Inst.)

    1993-04-01

    Regional cerebral blood flow was assessed in 19 patients with early idiopathic Parkinson's disease (PD) and 12 control subjects of similar age by single-photon emission tomography using technetium-99m hexamethylpropylene amine oxime (HMPAO). Of the patients with PD, seven were mildly demented and 15 presented with hemiparkinsonism. Mean HMPAO cortical or basal ganglia/cerebellum activity ratios were calculated. Mean cortical and regional uptake ratios in non-demented PD patients were not significantly different from values in the controls. In contrast, besides generalized cortical hypoperfusion, demented PD patients had significantly lower HMPAO uptake in the frontal and basal ganglia regions than non-demented patients. These observations support the hypothesis of impaired neuronal activity in both cortical and subcortical regions of the brain in demented PD patients. In hemiparkinsonian patients, the only asymmetrical finding was a relative hypoperfusion in the contralateral parietal region. This may be due to deafferentation of the thalamoparietal pathways. The lack of asymmetrical uptake in basal ganglia in our PD patients may be explained by their staging at the time of the investigation (stage I and II, Hoehn and Yahr scale). (orig.).

  14. Effects of non-linear flow and spatial orientation on technetium-99m hexamethylpropylene amine oxime single-photon emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Stapleton, S.J. [Toronto Univ., ON (Canada). Dept. of Medical Biophysics]|[Toronto Univ., ON (Canada). Dept. of Radiology; Caldwell, C.B. [Toronto Univ., ON (Canada). Dept. of Medical Biophysics]|[Toronto Univ., ON (Canada). Dept. of Radiology; Ehrlich, L.E. [Toronto Univ., ON (Canada). Dept. of Radiology; Leonhardt, C.L. [Toronto Univ., ON (Canada). Dept. of Radiology; Black, S.E. [Toronto Univ., ON (Canada). Dept. of Medicine; Yaffe, M.J. [Toronto Univ., ON (Canada). Dept. of Medical Biophysics]|[Toronto Univ., ON (Canada). Dept. of Radiology

    1995-09-01

    The effects of two post-acquisition corrections on the visual and quantitative analysis of technetium-99m hexamethylpropylene amine oxime (HMPAO) single-photon emission tomography (SPET) were determined. The corrections were for: (1) the improper spatial orientation of the patient data sets, and (2) the non-linear uptake of HMPAO across the blood-brain barrier. Reorienting the SPET image data sets removed observers` uncertainty in assessment caused by suspected head tilt; however, it increased their uncertainty due to perceived subtle perfusion deficits. Applying the correction to compensate for the decrease in uptake of HMPAO in high-flow regions resulted in an increase in the number of positive assessments. In a study involving 30 patient studies, intra-observer reliability increased from 62% to 83% (average of two observers) after applying both of the corrections, while inter-observer reliability improved from 62% to 81%. Quantitative methods of analysing the images are also affected by the corrections. In an ROI-based classification scheme, the quantitative assessments of more than one-half of the images are affected by the two corrections. These results need to be considered when comparing both quantitative and visual results from different studies in which the corrections may or may not have been applied. (orig.). With 3 figs., 4 tabs.

  15. Head sinuses, melon, and jaws of bottlenose dolphins, Tursiops truncatus, observed with computed tomography structural and single photon emission computed tomography functional imaging

    Science.gov (United States)

    Ridgway, Sam; Houser, Dorian; Finneran, James J.; Carder, Don; van Bonn, William; Smith, Cynthia; Hoh, Carl; Corbeil, Jacqueline; Mattrey, Robert

    2003-04-01

    The head sinuses, melon, and lower jaws of dolphins have been studied extensively with various methods including radiography, chemical analysis, and imaging of dead specimens. Here we report the first structural and functional imaging of live dolphins. Two animals were imaged, one male and one female. Computed tomography (CT) revealed extensive air cavities posterior and medial to the ear as well as between the ear and sound-producing nasal structures. Single photon emission computed tomography (SPECT) employing 50 mCi of the intravenously injected ligand technetium [Tc-99m] biscisate (Neurolite) revealed extensive and uptake in the core of the melon as well as near the pan bone area of the lower jaw. Count density on SPECT images was four times greater in melon as in the surrounding tissue and blubber layer suggesting that the melon is an active rather than a passive tissue. Since the dolphin temporal bone is not attached to the skull except by fibrous suspensions, the air cavities medial and posterior to the ear as well as the abutment of the temporal bone, to the acoustic fat bodies of each lower jaw, should be considered in modeling the mechanism of sound transmission from the environment to the dolphin ear.

  16. Association between somatization subscale score and serotonin transporter availability in healthy volunteers--a single photon emission computed tomography study with [¹²³I] ADAM.

    Science.gov (United States)

    Chou, Ming Hui; Chen, Kao Chin; Yeh, Tzung Lieh; Lee, I Hui; Yao, Wei Jen; Chen, Po See; Chang, Kang-Wei; Liao, Mei-Hsiu; Yang, Yen Kuang

    2012-02-01

    Serotonin is one of the key neuromodulators involved in fundamental cerebral functions and behaviors. Previous study has demonstrated that somatization symptoms are probably associated with central serotonergic circuits, which are implicated in anxiety and nociception regulation. This study aims to examine the correlation between somatization subscale score and serotonin transporter (SERT) availability in healthy volunteers. Sixty-four healthy participants, 26 males and 38 females, were enrolled from the community and were administered the single somatization subscale of the Chinese symptom checklist 90 revised (SCL90-R). Single photon emission computed tomography with [(123)I] 2-((2-((dimethylamino)methyl)phenyl)thio)-5-iodophenylamine was also performed to examine SERT availability. The somatization scores were negatively correlated with SERT availability (Spearman's ρ = -0.35, p = 0.005), particularly in males (Spearman's ρ = -0.54, p = 0.004). This result reconfirmed the correlation between central serotonergic activity and the intensity of somatization symptoms, even in healthy participants. However, a gender difference exists in this correlation.

  17. Influence of the Pixel Sizes of Reference Computed Tomography on Single-photon Emission Computed Tomography Image Reconstruction Using Conjugate-gradient Algorithm.

    Science.gov (United States)

    Okuda, Kyohei; Sakimoto, Shota; Fujii, Susumu; Ida, Tomonobu; Moriyama, Shigeru

    The frame-of-reference using computed-tomography (CT) coordinate system on single-photon emission computed tomography (SPECT) reconstruction is one of the advanced characteristics of the xSPECT reconstruction system. The aim of this study was to reveal the influence of the high-resolution frame-of-reference on the xSPECT reconstruction. 99mTc line-source phantom and National Electrical Manufacturers Association (NEMA) image quality phantom were scanned using the SPECT/CT system. xSPECT reconstructions were performed with the reference CT images in different sizes of the display field-of-view (DFOV) and pixel. The pixel sizes of the reconstructed xSPECT images were close to 2.4 mm, which is acquired as originally projection data, even if the reference CT resolution was varied. The full width at half maximum (FWHM) of the line-source, absolute recovery coefficient, and background variability of image quality phantom were independent on the sizes of DFOV in the reference CT images. The results of this study revealed that the image quality of the reconstructed xSPECT images is not influenced by the resolution of frame-of-reference on SPECT reconstruction.

  18. Change in size, shape and radiocolloid uptake of the alcoholic liver during alcohol withdrawal, as demonstrated by single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Blomquist, L. (Department of Clinical Alcohol and Drug Research, Internal Medicine, Karolinska Hopsital, Stockholm (Sweden)); Yansen Wang; Jacobsson, H. (Department of Diagnostic Radiology, Karolinska Hospital, Stockholm (Sweden)); Kimiaei, S. (Department of Hospital Physics, Karolinska Hospital, Stockholm (Sweden))

    1994-09-01

    The volume of the total liver and separate right and left lobes was studied before and after 1 week of alcohol withdrawal in 16 consecutive alcoholics by means of single photon emission computed tomography after intravenous injection of [sup 99]Tc[sup m]-human albumin colloid; the relative tissue distribution of radioactivity was also followed. The left liver lobe increased in volume more than the right lobe during drinking and decreased more rapidly after alcohol withdrawal. Median volume reductions during 1 week of alcohol withdrawal were: total liver 12%, left lob 26%, and right lobe 8%, indicating that half of the reduction to values of a control group was achieved during this first week. The volume of the right but not of the left lobe was significantly correlated to body size in alcoholics and in controls. The left lobe had a lower capacity to concentrate the radiocolloid than the right lobe in alcoholics and in controls. The liver/spleen, liver/bone marrow and liver/background radioactivity concentration ratios in the alcoholics increased during alcohol withdrawal We conclude that heavy drinking causes both an increased total liver volume and a change in liver shape, with a relatively more enlarged left right lobe, as well as a decreased capacity to concentrate radiocolloid. These changes are rapidly reversible during abstinence from alcohol. (au) (26 refs.).

  19. Prognostic impact of myocardial perfusion single photon emission computed tomography in patients with major extracardiac findings by computed tomography for attenuation correction.

    Science.gov (United States)

    Zadro, Charline; Roussel, Noé; Cassol, Emmanuelle; Pascal, Pierre; Petermann, Antoine; Meyrignac, Olivier; Jaffro, Marion; Fournier, Pauline; Cournot, Maxime; Galinier, Michel; Carrié, Didier; Rousseau, Hervé; Berry, Isabelle; Lairez, Olivier

    2017-03-09

    Attenuation correction computed tomography (CT) contributes to an improvement in the diagnostic accuracy of myocardial perfusion imaging (MPI) by single photon emission tomography (SPECT). The aim of this study was to explore the prognosis of patients with major findings by CT according to the results of MPI. 1506 patients who underwent MPI by SPECT were retrospectively included. Attenuation correction CT images were systematically analyzed for major and minor abnormalities. 830 (55.1%) and 212 (14.1%) patients had minor and major extracardiac findings, respectively. Among patients with major extracardiac findings, the abnormality was previously unknown in 113 (53.3%) patients. 90 (41.9%) had abnormal MPI, 73 (34.4%) had a myocardial infarction scar, 55 (25.9%) had myocardial ischemia, and 38 (17.7%) patients had both myocardial infarction scar and myocardial ischemia. Among the 201 patients available for survival analysis, there were 67 (31.2%) deaths over a follow-up period of 3.2±1.3 years. There was no significant impact on survival arising from MPI, whatever the result. The results were the same among the 103 patients with previously unknown major extracardiac findings. Extracardiac findings by CT during MPI are frequent. Patients with major extracardiac findings have a poor mid-term outcome, whatever the results of the myocardial perfusion imaging. Extracardiac findings should be systematically checked when attenuation correction CT is performed.

  20. Rapid and efficient radiosynthesis of [{sup 123}I]I-PK11195, a single photon emission computed tomography tracer for peripheral benzodiazepine receptors

    Energy Technology Data Exchange (ETDEWEB)

    Pimlott, Sally L. [Department of Clinical Physics, West of Scotland Radionuclide Dispensary, Western Infirmary, G11 6NT Glasgow (United Kingdom)], E-mail: s.pimlott@clinmed.gla.ac.uk; Stevenson, Louise [Department of Chemistry, WestCHEM, University of Glasgow, G12 8QQ Glasgow (United Kingdom); Wyper, David J. [Institute of Neurological Sciences, Southern General Hospital, G51 4TF Glasgow (United Kingdom); Sutherland, Andrew [Department of Chemistry, WestCHEM, University of Glasgow, G12 8QQ Glasgow (United Kingdom)

    2008-07-15

    Introduction: [{sup 123}I]I-PK11195 is a high-affinity single photon emission computed tomography radiotracer for peripheral benzodiazepine receptors that has previously been used to measure activated microglia and to assess neuroinflammation in the living human brain. This study investigates the radiosynthesis of [{sup 123}I]I-PK11195 in order to develop a rapid and efficient method that obtains [{sup 123}I]I-PK11195 with a high specific activity for in vivo animal and human imaging studies. Methods: The synthesis of [{sup 123}I]I-PK11195 was evaluated using a solid-state interhalogen exchange method and an electrophilic iododestannylation method, where bromine and trimethylstannyl derivatives were used as precursors, respectively. In the electrophilic iododestannylation method, the oxidants peracetic acid and chloramine-T were both investigated. Results: Electrophilic iododestannylation produced [{sup 123}I]I-PK11195 with a higher isolated radiochemical yield and a higher specific activity than achievable using the halogen exchange method investigated. Using chloramine-T as oxidant provided a rapid and efficient method of choice for the synthesis of [{sup 123}I]I-PK11195. Conclusions: [{sup 123}I]I-PK11195 has been successfully synthesized via a rapid and efficient electrophilic iododestannylation method, producing [{sup 123}I]I-PK11195 with a higher isolated radiochemical yield and a higher specific activity than previously achieved.

  1. Demonstration of a reduction in muscarinic receptor binding in early Alzheimer`s disease using iodine-123 dexetimide single-photon emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Claus, J.J. [Department of Neurology, Academic Medical Center, Amsterdam (Netherlands); Dubois, E.A. [Department of Nuclear Medicine, Academic Medical Center, Amsterdam (Netherlands); Booij, J. [Department of Nuclear Medicine, Academic Medical Center, Amsterdam (Netherlands); Habraken, J. [Department of Nuclear Medicine, Academic Medical Center, Amsterdam (Netherlands); Munck, J.C. van [The Netherlands Cancer Institute, Antoni van Leeuwenhoek Hospital, Amsterdam (Netherlands); Herk, M. van [The Netherlands Cancer Institute, Antoni van Leeuwenhoek Hospital, Amsterdam (Netherlands); Verbeeten, B. Jr. [Department of Radiology, Academic Medical Center, Amsterdam (Netherlands); Royen, E.A. van [Department of Nuclear Medicine, Academic Medical Center, Amsterdam (Netherlands)

    1997-06-10

    Decreased muscarinic receptor binding has been suggested in single-photon emission tomography (SPET) studies of Alzheimer`s disease. However, it remains unclear whether these changes are present in mildly demented patients, and the role of cortical atrophy in receptor binding assessment has not been investigated. We studied muscarinic receptor binding normalized to neostriatum with SPET using [{sup 123}I]4-iododexetimide in five mildly affected patients with probable Alzheimer`s disease and in five age-matched control subjects. Region of interest (ROI) analysis was performed in a consensus procedure blind to clinical diagnosis using matched magnetic resonance (MRI) images. Cortical atrophy was assessed by calculating percentages of cerebrospinal fluid in each ROI. An observer study with three observers was conducted to validate this method. Alzheimer patients showed statistically significantly less [{sup 123}I]4-iododexetimide binding in left temporal and right temporo-parietal cortex compared with controls, independent of age, sex and cortical atrophy. Mean intra-observer variability was 3.6% and inter-observer results showed consistent differences in [{sup 123}I]4-iododexetimide binding between observers. However, differences between patients and controls were comparable among observers and statistically significant in the same regions as in the consensus procedure. Using an MRI-SPET matching technique, we conclude that [{sup 123}I]4-iododexetimide binding is reduced in patients with mild probable Alzheimer`s disease in areas of temporal and temporo-parietal cortex. (orig.). With 1 fig., 4 tabs.

  2. Assessment of Gastric Accommodation in Patients with Functional Dyspepsia by 99mTc-Pertechtenate Single Photon Emission Computed Tomography Imaging: Practical but not Widely Accepted

    Directory of Open Access Journals (Sweden)

    Taghi Amiriani

    2015-10-01

    Full Text Available Objective: Impaired gastric accommodation is one of the main symptoms in patients with functional dyspepsia. The aim of the present study was to assess gastric accommodation in patients with functional dyspepsia using single photon emission computed tomography (SPECT imaging. Methods: Twenty-four patients with functional dyspepsia and 50 healthy volunteers as control group were enrolled in this study. All participants were given 5 mCi 99mTc-pertechtenate intravenously, served with a low fat meal, and underwent SPECT scanning 20 minutes after the meal. Results: Based on the scintigraphic data, gastric volumes were found to be significantly increased after food ingestion in both patient and control groups. We also found that while there was no significant difference between patient and control groups in terms of fasting gastric volumes, postprandial gastric volume was significantly lower in patients as compared to healthy individuals (p<0.05. Conclusion: Measuring gastric volume by using SPECT can be a valuable method in the detection of functional dyspepsia and in differentiation of this entity from other organic disorders.

  3. Diagnostic advantage of stress computed tomography myocardial perfusion over single-photon emission computed tomography for the assessment of myocardial ischemia.

    Science.gov (United States)

    Ueki, Yasushi; Izawa, Atsushi; Kashiwagi, Daisuke; Nishiyama, Shigeki; Aso, Shinichi; Suzuki, Chihiro; Sakurai, Shumpei; Oguchi, Kazuhiro; Yazaki, Yoshikazu; Ikeda, Uichi; Kuwahara, Koichiro

    2017-08-01

    This study compared adenosine stress computed tomography myocardial perfusion (CTP) with single-photon emission computed tomography (SPECT) in the diagnosis of functionally significant coronary artery stenosis using fractional flow reserve (FFR) as reference standard. We included a total of 93 coronary arteries from 31 patients in whom at least one vessel with ≥50% stenosis was detected with computed tomography coronary angiography. All patients underwent both SPECT and adenosine stress CTP, followed by invasive coronary angiography (ICA) and FFR. Diagnostic accuracy between CTP and SPECT was compared according to positive findings of either ≥99% stenosis on ICA or FFR ≤0.8. Among 78 vessels eligible for the quantitative analyses, significant coronary artery disease (CAD) was diagnosed in 22 vessels of 19 patients. Comparison of CTP vs. SPECT for sensitivity, specificity, positive predictive value (PPV), negative predictive value, and accuracy in detecting significant CAD were 59% vs. 18%, 96% vs. 93%, 87% vs. 50%, 86% vs. 74%, and 86% vs. 72%, respectively. CTP demonstrated a significant diagnostic advantage over SPECT in the identification of significant CAD, especially in terms of sensitivity and PPV. Adenosine stress CTP is useful for the noninvasive diagnosis of functionally significant CAD. Copyright © 2016 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  4. Influence of Respiratory Gating, Image Filtering, and Animal Positioning on High-Resolution Electrocardiography-Gated Murine Cardiac Single-Photon Emission Computed Tomography

    Directory of Open Access Journals (Sweden)

    Chao Wu

    2015-01-01

    Full Text Available Cardiac parameters obtained from single-photon emission computed tomographic (SPECT images can be affected by respiratory motion, image filtering, and animal positioning. We investigated the influence of these factors on ultra-high-resolution murine myocardial perfusion SPECT. Five mice were injected with 99m technetium (99mTc-tetrofosmin, and each was scanned in supine and prone positions in a U-SPECT-II scanner with respiratory and electrocardiographic (ECG gating. ECG-gated SPECT images were created without applying respiratory motion correction or with two different respiratory motion correction strategies. The images were filtered with a range of three-dimensional gaussian kernels, after which end-diastolic volumes (EDVs, end-systolic volumes (ESVs, and left ventricular ejection fractions were calculated. No significant differences in the measured cardiac parameters were detected when any strategy to reduce or correct for respiratory motion was applied, whereas big differences (> 5% in EDV and ESV were found with regard to different positioning of animals. A linear relationship (p < .001 was found between the EDV or ESV and the kernel size of the gaussian filter. In short, respiratory gating did not significantly affect the cardiac parameters of mice obtained with ultra-high-resolution SPECT, whereas the position of the animals and the image filters should be the same in a comparative study with multiple scans to avoid systematic differences in measured cardiac parameters.

  5. The role of striatal dopamine D2 receptors in the occurrence of extrapyramidal side effects: iodine-123-iodobenzamide single photon emission computed tomography study.

    Science.gov (United States)

    Corripio, Iluminada; Ferreira, Alcides; Portella, Maria J; Pérez, Víctor; Escartí, María J; Del Valle Camacho, Maria; Sauras, Rosa B; Alonso, Anna; Grasa, Eva Ma; Carrió, Ignasi; Catafau, Ana M; Alvarez, Enric

    2012-01-30

    Levels above 75% of striatal dopamine 2 receptor occupancy (D2RO) have been associated with extrapyramidal symptoms (EPS). The aim of the present study is to investigate the relationship between D2RO and EPS in a sample of psychotic patients in current treatment with both typical and atypical antipsychotics. Brain iodine-123-iodobenzamide single photon emission computed tomography ((123)I-IBZM SPECT) was performed in 81 patients taking stable doses of haloperidol, risperidone, olanzapine, quetiapine, clozapine or ziprasidone. First, the degree of D2RO and Positive and Negative Syndrome Scale (PANSS) scores was compared between the group of patients who presented EPS and the group free of EPS. Afterwards, these variables were compared among the different antipsychotic medications. The group with EPS presented means of D2RO significantly higher than the group free of EPS. Significant differences in D2RO were found in clozapine, quetiapine and ziprasidone groups compared with the haloperidol group. No differences were observed between either olanzapine or risperidone and haloperidol. No quetiapine- or clozapine-treated patients developed EPS. Haloperidol and risperidone demonstrated a relationship between striatal D2RO and EPS. The findings suggest that higher D2RO is related to appearance of EPS. Occupancy in the group with EPS was in agreement with previous studies that suggested a high degree of D2RO is necessary for the occurrence of EPS. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  6. Deep serotonergic and dopaminergic structures in fetal alcoholic syndrome: a study with nor-beta-CIT-single-photon emission computed tomography and magnetic resonance imaging volumetry.

    Science.gov (United States)

    Riikonen, Raili S; Nokelainen, Pekka; Valkonen, Kirsi; Kolehmainen, Anni I; Kumpulainen, Kirsti I; Könönen, Mervi; Vanninen, Ritva-Liisa S; Kuikka, Jyrki T

    2005-06-15

    In prenatally alcohol exposed children, the relationship between brain structure and function is highlighted to be important to study. We studied 12 children with fetal alcoholic syndrome (FAS) and fetal alcoholic effects (FAE) by magnetic resonance imaging volumetry and by single-photon emission computed tomography with iodine-123 labeled 2beta-carbomethoxy-3beta-(4-iodophenyl) ([123I]nor-beta-CIT) and related these findings to those from neuropsychological and psychiatric tests. The absolute volumes of studied nuclei, including the brain volume, were significantly smaller in FAS/FAE children than in control patients. After normalization of volumes, significant differences were not found. Left hippocampus was smaller than the right (pADHD). None had depression. The internalization scores correlated with dopamine transporter binding (r=-.65; p=.03). The results indicate that the serotonin (5-HT) system may be vulnerable to the effects of ethanol in utero. The high dopamine transporter levels may correlate with the ADHD findings. Reduced serotonin and increased binding of dopamine transporter are also seen in type 2 alcoholism. Some behavioral problems of FAS/FAE might be preventable by early intervention and treatment.

  7. Prognostic value of technetium-99m-labeled single-photon emission computerized tomography in the follow-up of patients after their first myocardial revascularization surgery

    Directory of Open Access Journals (Sweden)

    Márcia Maria Sales dos Santos

    2003-01-01

    Full Text Available OBJECTIVE: To assess the prognostic value of Technetium-99m-labeled single-photon emission computerized tomography (SPECT in the follow-up of patients who had undergone their first myocardial revascularization. METHODS: We carried out a retrospective study of 280 revascularized patients undergoing myocardial scintigraphy under stress (exercise or pharmacological stress with dipyridamole and at rest according to a 2-day protocol. A set of clinical, stress electrocardiographic and scintigraphic variables was assessed. Cardiac events were classified as "major" (death, infarction, unstable angina and "any" (major event or coronary angioplasty or new myocardial revascularization surgery. RESULTS: Thirty-six major events occurred as follows: 3 deaths, 11 infarctions, and 22 unstable anginas. In regard to any event, 22 angioplasties and 7 new surgeries occurred in addition to major events, resulting a total of 65 events. The sensitivity of scintigraphy in prognosticating a major event or any event was, respectively, 55% and 58%, showing a negative predictive value of 90% and 83%, respectively. Diabetes mellitus, inconclusive stress electrocardiography, and a scintigraphic visualization of left ventricular enlargement were significant variables for the occurrence of a major event. On multivariate analysis, abnormal myocardial scintigraphy was a predictor of any event. CONCLUSION: Myocardial perfusion tomography with Technetium-99m may be used to identify high-risk patients after their first myocardial revascularization surgery.

  8. Dopamine D[sub 2]-receptors in human narcolepsy. A SPECT study with [sup 123]I-IB. [Single Photon Emission Computed Tomography. Iodobenzamide

    Energy Technology Data Exchange (ETDEWEB)

    Hublin, C. (Department of Ullanlinna Sleep Research Centre, Kivelae Hospital, Helsinki (Finland)); Launes, J. (Department of Neurology, Helsinki University Central Hospital (Finland)); Nikkinen, P. (Department of Clinical Chemistry, Division of Nuclear Medicine, Helsinki University Central Hospital (Finland)); Partinen, M. (Department of Neurological Unit of Kivelae Hospital, Helsinki (Finland))

    1994-09-01

    Increased dopamine D[sub 2] receptor binding in basal ganglia has been reported in human narcolepsy. These studies have been based on post-mortem material of 8 patients, most of them also medicated for narcolepsy. We studied six narcoleptics without stimulant or anticataplectic medication. The patients had an unambiguous history of cataplexy, and they were also studied polygraphically. Single photon emission computed tomography (SPECT) imaging was performed. The D[sub 2] receptor density wad determined by using [sup 123]I-iodobenzamide (IBZM). The control subjects were 8 unmedicated Parkinson patients with one-sided (hemiparkinsonian) clinical symptoms. The D[sub 2] receptor density in them is known to be normal or somewhat increased compared to healthy normals. The striatum/frontal D[sub 2] activity ratio was 1.331 [+-] 0.084 (with phantom study correction 2.101 [+-] 0.300) in the narcoleptic patients, and in the parkinsonian controls 1.321 [+-] 0.052 (2.067 [+-] 0.185) for the asymptomatic side and 1.335 [+-] 0.025 (2.117 [+-] 0.090) for the symptomatic side (i.e. contralateral to the side with the clinical extrapyramidal signs). There was no statistical difference between the groups or between the symptomatic and asymptomatic side in the Parkinson patients. Thus, our results differ from the earlier post-mortem studies. (au) (28 refs.).

  9. Cortical perfusion response to an electrical stimulation of the auditory nerve in profoundly deaf patients: Study with technetium-99m hexamethylpropylene amine oxime single photon emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Le Scao, Y.; Robier, A.; Beuter, P. (Centre Hospitalier Universitaire, 37 - Tours (France). Dept. of Otorhinolaryngology); Baulieu, J.L.; Pourcelot, L. (Centre Hospitalier Universitaire, 37 - Tours (France). Dept. of Nuclear Medicine)

    1992-04-01

    Brain activation procedures associated with single photon emission tomography (SPET) have recently been developed in healthy controls and diseased patients in order to help in their diagnosis and treatment. We investigated the effects of a promontory test (PT) on the cerebral distribution of technetium-99m hexamethyl-propylene amine oxime ({sup 99m}Tc-HMPAO) in 7 profoundly deaf patients, 6 PT+ and PT-. The count variation in the temporal lobe was calculated on 6 coronal slices using the ratio (R{sub stimulation}-R{sub deprivation})/R{sub deprivation} where R=counts in the temporal lobe was observed in all patients and was higher in all patients with PT+ than in the patient with PT-. The problems of head positioning and resolution of the system were taken into account, and we considered that the maximal count increment was related to the auditory cortex response to the stimulus. Further clinical investigations with high-resolution systems have to be performed in order to validate this presurgery test in cochlear implant assessment. (orig.).

  10. Blood flow measurement in extremity soft tissue sarcoma with technetium-99m hexamethyl-propyleneamineoxime and single photon emission computed tomography.

    Science.gov (United States)

    Hill, S; Heary, T; Flower, M A; Cronin, B; McCready, V R; Thomas, J M

    1994-11-01

    Blood flow measurements were made in 28 patients with soft tissue sarcoma of the extremities to investigate the prognostic significance of tumour vascularity. Four patients with benign tumours also underwent blood flow measurement. Mean and maximum tumour blood flow was calculated from technetium-99m hexamethyl-propyleneamineoxime uptake measured using single photon emission computed tomography (SPECT), tumour volume measured from SPECT transaxial image reconstructions and cardiac output assessed with Doppler ultrasonography. Twenty-seven malignant lesions and one benign tumour showed increased uptake of isotope relative to surrounding tissues. Mean sarcoma blood flow varied between 1 and 33 ml per 100 ml tumour per min, and maximum flow between 5 and 57 ml per 100 ml per min. Fourteen patients developed progressive disease during the first year of follow-up. Eight of 11 patients with a high isotope uptake ratio, eight of 12 with a high mean blood flow and eight of 14 with a high maximum blood flow relative to the respective medians for the series showed disease progression.

  11. Cerebral blood flow measurement in patients with impaired consciousness: usefulness of {sup 99m}Tc-HMPAO single-photon emission tomography in clinical practice

    Energy Technology Data Exchange (ETDEWEB)

    Chang Chia-Cheng; Kuwana, Nobumasa; Noji, Masato; Tanabe, Yutaka; Koike, Y. [Department of Neurosurgery, Yokohama Minami Kyosai Hospital, Yokohama (Japan); Ikegami, Tadashi [Department of Radiology, Yokohama Minami Kyosai Hospital, Yokohama (Japan)

    1998-09-01

    The relationship between impairment of consciousness and quantitative cerebral blood flow (CBF) was investigated. The mean CBF of the whole brain was measured by the Patlak-plot method using technetium-99m hexamethylpropylene amine oxime single-photon emission tomography ({sup 99m}Tc-HMPAO SPET) in patients with the following diseases: cerebral infarction, intraparenchymal haemorrhage, subarachnoid haemorrhage, brain tumour and cerebral contusion. The clinical symptoms were evaluated according to the severity of impaired consciousness, aphasia and dementia. Four hundred and eighty-five CBF measurements were performed. Patients with alert consciousness showed an age-related decline in mean CBF. Patients with aphasia showed a significant reduction in mean CBF compared with those without aphasia. Impaired consciousness was proportional to reduction in mean CBF regardless of types of pathology, and the size of lesion did not influence the mean CBF. Patients with dementia showed a significant reduction in mean CBF proportional to the severity of dementia. The quantitative measurement of CBF using {sup 99m}Tc-HMPAO SPET is reliable in clinical evaluations. (orig.) With 3 tabs., 10 refs.

  12. Evaluation of the diagnostic and prognostic use of gated myocardial perfusion single-photon emission computed tomography in patients with acute chest pain: comparison with the SYNTAX score.

    Science.gov (United States)

    Karacavus, Seyhan; Tutus, Ahmet; Topsakal, Ramazan; Kula, Mustafa; Celik, Ahmet; Abdulrezzak, Ummuhan; Durukan, Polat

    2015-09-01

    The aim of this study was to evaluate the diagnostic and prognostic efficacy of gated single-photon emission computed tomography (GSPECT) in patients with acute chest pain and to compare quantitative GSPECT parameters and the coronary angiographic SYNTAX score. A total of 168 patients who presented with clinical symptoms of acute chest pain were enrolled in the study. Study participants were divided into two groups according to the risk of acute coronary syndrome (ACS): low-intermediate and high risk. All participants underwent rest or stress-GSPECT (R/S-GSPECT). Coronary angiography was performed in all high-risk patients and the SYNTAX score was determined. All patients were followed for 24 ± 3 months and monitored for the occurrence of major adverse coronary events (MACE). Among patients with low-intermediate ACS risk, R-GSPECT and S-GSPECT were associated with 100 and 86% sensitivity, 99 and 98% specificity, 100 and 98% negative predictive value, 80 and 86% positive predictive value, and 98 and 97% accuracy, respectively. At follow-up, MACE occurred in 16 patients. Among high-risk patients, GSPECT quantitative parameters were the most significant predictors of MACE in Cox regression analysis. R/S-GSPECT, a noninvasive diagnostic method, is associated with an excellent safety profile and exceptional diagnostic and prognostic accuracy in cases of ACS.

  13. Rapid and efficient radiosynthesis of [123I]I-PK11195, a single photon emission computed tomography tracer for peripheral benzodiazepine receptors.

    Science.gov (United States)

    Pimlott, Sally L; Stevenson, Louise; Wyper, David J; Sutherland, Andrew

    2008-07-01

    [(123)I]I-PK11195 is a high-affinity single photon emission computed tomography radiotracer for peripheral benzodiazepine receptors that has previously been used to measure activated microglia and to assess neuroinflammation in the living human brain. This study investigates the radiosynthesis of [(123)I]I-PK11195 in order to develop a rapid and efficient method that obtains [(123)I]I-PK11195 with a high specific activity for in vivo animal and human imaging studies. The synthesis of [(123)I]I-PK11195 was evaluated using a solid-state interhalogen exchange method and an electrophilic iododestannylation method, where bromine and trimethylstannyl derivatives were used as precursors, respectively. In the electrophilic iododestannylation method, the oxidants peracetic acid and chloramine-T were both investigated. Electrophilic iododestannylation produced [(123)I]I-PK11195 with a higher isolated radiochemical yield and a higher specific activity than achievable using the halogen exchange method investigated. Using chloramine-T as oxidant provided a rapid and efficient method of choice for the synthesis of [(123)I]I-PK11195. [(123)I]I-PK11195 has been successfully synthesized via a rapid and efficient electrophilic iododestannylation method, producing [(123)I]I-PK11195 with a higher isolated radiochemical yield and a higher specific activity than previously achieved.

  14. Receptor binding characterization of the benzodiazepine radioligand sup 125 I-Ro16-0154: Potential probe for SPECT (Single Photon Emission Computed Tomography) brain imaging

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, E.W.; Woods, S.W.; Zoghbi, S.; Baldwin, R.M.; Innis, R.B. (Yale Univ., West Haven, CT (USA)); McBride, B.J. (Medi-Physics, Inc., Emeryville, CA (USA))

    1990-01-01

    The binding of an iodinated benzodiazepine (BZ) radioligand has been characterized, particularly in regard to its potential use as a neuroreceptor brain imaging agent with SPECT (Single Photon Emission Computed Tomography). Ro16-0154 is an iodine-containing BZ antagonist and a close analog of Ro15-1788. In tissue homogenates prepared from human and monkey brain, the binding of {sup 125}I-labeled Ro16-0154 was saturable, of high affinity, and had high ratios of specific to non-specific binding. Physiological concentrations of NaCl enhanced specific binding approximately 15% compared to buffer without this salt. Kinetic studies of association and dissociation demonstrated a temperature dependent decrease in affinity with increasing temperature. Drug displacement studies confirmed that {sup 125}I-Ro16-0154 binds to the central type BZ receptor: binding is virtually identical to that of {sup 3}H-Ro15-1788 except that {sup 125}I-Ro16-0154 shows an almost 10 fold higher affinity at 37{degree}C. These in vitro results suggest that {sup 123}I-labeled Ro16-0154 shows promise as a selective, high affinity SPECT probe of the brain's BZ receptor.

  15. Comparative study of body surface isopotential map, left ventriculogram and thallium-201 myocardial scintigram in patients with old lateral myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Naoyuki

    1988-01-01

    In 16 patients with old lateral myocardial infarction, body surface isopotential maps and 12 lead electrocardiograms were compared with left ventriculographic findings. In addition 8 of these subjects were performed thallium-201 myocardial scintigraphy in order to determine the location and extent of myocardial necrosis. Common 12 lead electrocardiographic findings of the subjects were initial Q waves more than 30 msec and inverted T waves in only aVL lead. The patients were classified into 4 groups according to the location and extent of ventricular wall motion abnormalities group I (6 cases) showed hypokinesis in the anterior segment, group II (5 cases): akinesis in the anterior segment and hypokinesis in the seg. 6, group III (4 cases): hypokinesis in the anterior segment and seg. 7, group IV (1 case): hypokinesis in the anterior segment and seg. 4, 7. And each of the 4 groups demonstrated characteristic findings of surface isopotential maps. Group II with coexisting hypokinesis in the seg. 6 showed surface isopotential maps additional pattern of anterior myocardial infarction, and group III with coexisting hypokinesis in the seg. 7 showed additional patterns of posterior myocardial infarction. The classification according to the abnormality of ventricular wall motion was also conformed with the thallium-201 myocardial scintigraphic findings except one case. These results suggest that body surface isopotential map is more useful than the 12 lead electrocardiogram in detecting the location and extent of left ventricular wall motion abnormality in patients with old lateral myocardial infarction. (author) 53 refs.

  16. Iodine-123 N-methyl-4-iododexetimide: a new radioligand for single-photon emission tomographic imaging of myocardial muscarinic receptors

    Energy Technology Data Exchange (ETDEWEB)

    Hicks, R.J. [Heidelberg Hospital, Melbourne, VIC (Australia); Kassiou, M. [Biomedicine and Health Div., Australian Nuclear Science and Technology Organisation, Sydney, NSW (Australia); Eu, P. [Heidelberg Hospital, Melbourne, VIC (Australia); Katsifis, A.G. [Biomedicine and Health Div., Australian Nuclear Science and Technology Organisation, Sydney, NSW (Australia); Garra, M. [Heidelberg Hospital, Melbourne, VIC (Australia); Power, J. [Heidelberg Hospital, Melbourne, VIC (Australia); Najdovski, L. [Biomedicine and Health Div., Australian Nuclear Science and Technology Organisation, Sydney, NSW (Australia); Lambrecht, R.M. [Biomedicine and Health Div., Australian Nuclear Science and Technology Organisation, Sydney, NSW (Australia)

    1995-04-01

    Cardiac muscarinic receptor ligands suitable for positron emission tomography have previously been characterised. Attempts to develop radioligands of these receptors suitable for single-photon emission tomographic (SPET) imaging have not been successful due to high lung retention and high non-specific binding of previously investigated potential tracers. The purpose of this study was to evaluate the biodistribution and in vivo imaging characteristics of a new radiopharmaceutical, [{sup 123}I]N-methyl-4-iododexetimide. Biodistribution studies performed in rats showed high cardiac uptake (2.4% ID/g) 10 min after injection with a heart to lung activity ratio of 5:1. Specificity and stereoselectivity of cardiac binding were demonstrated using blocking experiments in rats. Dynamic imaging studies in anaesthetised greyhounds demonstrated rapid and high myocardial uptake and low lung binding with stable heart to lung activity ratios of >2.5:1 between 10 and 30 min, making SPET imaging feasible. Administration of an excess of an unlabelled muscarinic antagonist, methyl-quinuclidinyl benzylate rapidly displaced myocardial activity to background levels and the pharmacologically inactive enantiomer, [{sup 123}I]N-methyl-4-iodolevetimide, had no detectable cardiac uptake, indicating specific and stereoselective muscarinic receptor binding. SPET revealed higher activity in the inferior than in the anterior wall, this being consistent with previously described regional variation of cardiac parasympathetic innervation. [{sup 123}I]N-methyl-4-iododexetimide shows promise as an imaging agent for muscarinic receptor distribution in the heart and may be helpful in evaluating diverse cardiac diseases associated with altered muscarinic receptor function, including heart failure and diabetic heart disease. (orig.)

  17. Assessment of myocardial viability by dynamic tomographic iodine 123 iodophenylpentadecanoic acid imaging: comparison with rest-redistribution thallium 201 imaging.

    Science.gov (United States)

    Iskandrian, A S; Powers, J; Cave, V; Wasserleben, V; Cassell, D; Heo, J

    1995-01-01

    This study examined the ability of dynamic 123I-labeled iodophenylpentadecanoic acid (IPPA) imaging to detect myocardial viability in patients with left ventricular (LV) dysfunction caused by coronary artery disease. Serial 180-degree single-photon emission computed tomographic (SPECT) images (five sets, 8 minutes each) were obtained starting 4 minutes after injection of 2 to 6 mCi 123I at rest in 21 patients with LV dysfunction (ejection fraction [EF] 34% +/- 11%). The segmental uptake was compared with that of rest-redistribution 201Tl images (20 segments/study). The number of perfusion defects (reversible and fixed) was similar by IPPA and thallium (11 +/- 5 vs 10 +/- 5 segments/patient; difference not significant). There was agreement between IPPA and thallium for presence or absence (kappa = 0.78 +/- 0.03) and nature (reversible, mild fixed, or severe fixed) of perfusion defects (kappa = 0.54 +/- 0.04). However, there were more reversible IPPA defects than reversible thallium defects (7 +/- 4 vs 3 +/- 4 segments/patient; p = 0.001). In 14 patients the EF (by gated pool imaging) improved after coronary revascularization from 33% +/- 11% to 39% +/- 12% (p = 0.002). The number of reversible IPPA defects was greater in the seven patients who had improvement in EF than in the patients without such improvement (10 +/- 4 vs 5 +/- 4 segments/patient; p = 0.075). 123I-labeled IPPA SPECT imaging is a promising new technique for assessment of viability. Reversible defects predict recovery of LV dysfunction after coronary revascularization.

  18. Synthesis and characterization of radioiodinated MD-230254. A new ligand for potential imaging of monoamine oxidase B activity by single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Hirata, Masahiko; Kagawa, Shinya; Yoshimoto, Mitsuyoshi; Ohmomo, Yoshiro [Osaka Univ. of Pharmaceutical Sciences, Takatsuki (Japan)

    2002-05-01

    A series of iodinated analogues of MD-230254 was synthesized and evaluated for inhibitory potency and selectivity toward monoamine oxidase B (MAO-B). Among them, 5-[4-(2-iodobenzyloxy)phenyl]-3(cyanoethyl)-1,3,4-oxadiazole-2(3H)one (2-IBPO) was found to have high inhibitory potency and selectivity toward MAO-B (IC{sub 50}=2.0 n{sub M}, MAO-A/MAO-B>50000). Analysis of the inhibition kinetics indicated that 2-IBPO acts in a two-step mechanism as a competitive, slow, and tight-binding inhibitor of MAO-B with a Ki value of 2.4 n{sub M} and an overall Ki value at an equilibrium of 3.8 n{sub M}. The new radioligand for MAO-B, [{sup 125}I]2-IBPO was conveniently synthesized from a tributylstannyl precursor by an iododestannylation reaction using sodium [{sup 125}I]iodide and hydrogen peroxide with high radiochemical yield. The in vivo tissue distribution studies of [{sup 125}I]2-IBPO demonstrated its high initial uptake and prolonged retention in the brain. A selective interaction of [{sup 125}I]2-IBPO with MAO-B was confirmed by the pretreatment experiment with well known MAO specific inhibitors, l-deprenyl, Ro-16-6491, clorgyline, and Ro-41-1049. These very desirable characteristics of [{sup 125}I]2-IBPO suggested that a {sup 123}I-labeled counterpart, [{sup 123}I]2-IBPO, would have great potential in vivo studies of MAO-B in the human brain with single photon emission computed tomography (SPECT). (author)

  19. Evaluation of left ventricular function and volumes in patients with ischaemic cardiomyopathy: gated single-photon emission computed tomography versus two-dimensional echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Vourvouri, E.C.; Poldermans, D.; Sianos, G.; Sozzi, F.B.; Schinkel, A.F.L.; Sutter, J. de; Roelandt, J.R.T.C. [Dept. of Cardiology, Erasmus Medical Center Rotterdam (Netherlands); Bax, J.J. [Dept. of Cardiology, Leiden Univ. Medical Center (Netherlands); Parcharidis, G. [Dept. of Cardiology, AHEPA Univ. Hospital, Thessaloniki (Greece); Valkema, R. [Dept. of Nuclear Medicine, Erasmus Medical Center Rotterdam (Netherlands)

    2001-11-01

    The objective of this study was to perform a head-to-head comparison between two-dimensional (2D) echocardiography and gated single-photon emission computed tomography (SPET) for the evaluation of left ventricular (LV) function and volumes in patients with severe ischaemic LV dysfunction. Thirty-two patients with chronic ischaemic LV dysfunction [mean LV ejection fraction (EF) 25%{+-}6%] were studied with gated SPET and 2D echocardiography. Regional wall motion was evaluated by both modalities and scored by two independent observers using a 16-segment model with a 5-point scoring system (1= normokinesia, 2= mild hypokinesia, 3= severe hypokinesia, 4= akinesia and 5= dyskinesia). LVEF and LV end-diastolic and end-systolic volumes were evaluated by 2D echocardiography using the Simpson's biplane discs method. The same parameters were calculated using quantitative gated SPET software (QGS, Cedars-Sinai Medical Center). The overall agreement between the two imaging modalities for assessment of regional wall motion was 69%. The correlations between gated SPET and 2D echocardiography for the assessment of end-diastolic and end-systolic volumes were excellent (r=0.94, P<0.01, and r=0.96, P<0.01, respectively). The correlation for LVEF was also good (r=0.83, P<0.01). In conclusion: in patients with ischaemic cardiomyopathy, close and significant relations between gated SPET and 2D echocardiography were observed for the assessment of regional and global LV function and LV volumes; gated SPET has the advantage that it provides information on both LV function/dimensions and perfusion. (orig.)

  20. Perfusion impairments in infantile autism on technetium-99m ethyl cysteinate dimer brain single-photon emission tomography: comparison with findings on magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Y.H.; Lee, J.D.; Yoon, P.H.; Kim, D.I. [Division of Nuclear Medicine, Department of Diagnostic Radiology, Yonsei University College of Medicine, Seoul (Korea, Republic of); Lee, H.B.; Shin, Y.J. [Department of Psychiatry, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1999-03-01

    The neuro-anatomical substrate of autism has been the subject of detailed investigation. Because previous studies have not demonstrated consistent and specific neuro-imaging findings in autism and most such studies have been performed in adults and school-aged children, we performed a retrospective review in young children in search of common functional and anatomical abnormalities with brain single-photon emission tomography (SPET) using technetium-99m ethyl cysteinate dimer (ECD) and correlative magnetic resonance imaging (MRI). The patient population was composed of 23 children aged 28-92 months (mean: 54 months) who met the diagnostic criteria of autism as defined in the DSM-IV and CARS. Brain SPET was performed after intravenous injection of 185-370 MBq of {sup 99m}Tc-ECD using a brain-dedicated annular crystal gamma camera. MRI was performed in all patients, including T1, T2 axial and T1 sagittal sequences. SPET data were assessed visually. Twenty patients had abnormal SPET scans revealing focal areas of decreased perfusion. Decreased perfusion of the cerebellar hemisphere (20/23), thalami (19/23), basal ganglia (5/23) and posterior parietal (10/23) and temporal (7/23) areas were noted on brain SPET. By contrast all patients had normal MRI findings without evidence of abnormalities of the cerebellar vermis, cerebellar hemisphere, thalami, basal ganglia or parietotemporal cortex. In conclusion, extensive perfusion impairments involving the cerebellum, thalami and parietal cortex were found in this study. SPET may be more sensitive in reflecting the pathophysiology of autism than MRI. However, further studies are necessary to determine the significance of thalamic and parietal perfusion impairment in autism. (orig.) With 2 figs., 1 tab., 33 refs.

  1. Measurement of porto-systemic shunting in mice by novel three-dimensional micro-single photon emission computed tomography imaging enabling longitudinal follow-up.

    Science.gov (United States)

    Van Steenkiste, Christophe; Staelens, Steven; Deleye, Steven; De Vos, Filip; Vandenberghe, Stefaan; Geerts, Anja; Van de Wiele, Christophe; De Vos, Martine; Van Vlierberghe, Hans; Colle, Isabelle

    2010-09-01

    The reference method for diagnosing porto-systemic shunting (PSS) in experimental portal hypertension involves measuring (51)Chrome ((51)Cr)-labelled microspheres. Unfortunately, this technique necessitates the sacrifice of animals. Alternatively, (99m)technetium-macroaggregated albumin ((99m)Tc-MAA) has been used; however, planar scintigraphy imaging techniques are not quantitatively accurate and adequate spatial information is not attained. Here, we describe a reliable, minimally invasive and rapid in vivo imaging technique, using three-dimensional single photon emission computed tomography (3D SPECT) modus, that allows more accurate quantification, serial measurements and spatial discrimination. Partial portal vein ligation, common bile duct ligation and sham were induced in male mice. A mixture of (51)Cr microspheres and (99m)Tc-macroaggregated albumin particles was injected into the splenic pulpa. All mice were scanned in vivo with microSPECT (1 mm spatial resolution) and, when mandatory for localisation, a microSPECT-CT was acquired. A relative quantitative analysis was performed based on the 3D reconstructed datasets. Additionally, (51)Cr was measured in the same animals to calculate the correlation coefficient between the (99m)Tc detection and the gold standard (51)Cr. In each measuring modality, the PSS fraction was calculated using the formula: [(lung counts)/(lung counts+liver counts)] x 100. A significant correlation between the (99m)Tc detection and (51)Cr was demonstrated in partial portal vein ligation, common bile duct ligation and sham mice and there was a good agreement between the two modalities. MicroSPECT scanning delivers high spatial resolution and 3D image reconstructions. We have demonstrated that quantitative high-resolution microSPECT imaging with (99m)Tc-MAA is useful for detecting the extent of PSS in a non-sacrificing set-up. This technology permits serial measurements and high-throughput screening to detect baseline PSS, which is

  2. Correlative single photon emission computed tomography imaging of [{sup 123}I]altropane binding in the rat model of Parkinson's

    Energy Technology Data Exchange (ETDEWEB)

    Gleave, Jacqueline A. [Department of Pathology and Molecular Medicine, McMaster University, 1200 Main Street West, Hamilton, Ontario, L8N 3Z5 (Canada); Farncombe, Troy H.; Saab, Chantal [Department of Nuclear Medicine, Hamilton Health Sciences, Hamilton, Ontario, L8N 3Z5 (Canada); Doering, Laurie C., E-mail: doering@mcmaster.ca [Department of Pathology and Molecular Medicine, McMaster University, 1200 Main Street West, Hamilton, Ontario, L8N 3Z5 (Canada)

    2011-07-15

    Introduction: This study used the dopamine transporter (DAT) probe, [{sup 123}I]-2{beta}-carbomethoxy-3{beta}-(4-fluorophenyl)-N-(3-iodo-E-allyl)nortropane ([{sup 123}I]altropane), to assess the DAT levels in the 6-hydroxydopamine rat model of Parkinson's disease. We sought to assess if the right to left [{sup 123}I]altropane striatal ratios correlated with dopamine content in the striatum and substantia nigra and with behavioural outcomes. Methods: [{sup 123}I]altropane images taken pre- and postlesion were acquired before and after the transplantation of neural stem/progenitor cells. The images obtained using [{sup 123}I]altropane and single photon emission computed tomography (SPECT) were compared with specific behavioural tests and the dopamine content assessed by high-performance liquid chromatography. Results: [{sup 123}I]altropane binding correlated with the content of dopamine in the striatum; however, [{sup 123}I]altropane binding did not correlate with the dopamine content in the substantia nigra. There was a significant correlation of altropane ratios with the cylinder test and the postural instability test, but not with amphetamine rotations. The low coefficient of determination (r{sup 2}) for these correlations indicated that [{sup 123}I]altropane SPECT was not a good predictor of behavioural outcomes. Conclusion: Our data reveal that [{sup 123}I]altropane predicts the integrity of the striatal dopamine nerve terminals, but does not predict the integrity of the nigrostriatal system. [{sup 123}I]altropane could be a useful marker to measure dopamine content in cell replacement therapies; however, it would not be able to evaluate outcomes for neuroprotective strategies.

  3. Novel application of quantitative single-photon emission computed-tomography/computed tomography to predict early response to methimazole in Graves' disease

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Joo; Bang, Ji In; Kim, Ji Young; Moon, Jae Hoon [Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam (Korea, Republic of); So, Young [Dept. of Nuclear Medicine, Konkuk University Medical Center, Seoul (Korea, Republic of); Lee, Won Woo [Institute of Radiation Medicine, Medical Research Center, Seoul National University, Seoul (Korea, Republic of)

    2017-06-15

    Since Graves' disease (GD) is resistant to antithyroid drugs (ATDs), an accurate quantitative thyroid function measurement is required for the prediction of early responses to ATD. Quantitative parameters derived from the novel technology, single-photon emission computed tomography/computed tomography (SPECT/CT), were investigated for the prediction of achievement of euthyroidism after methimazole (MMI) treatment in GD. A total of 36 GD patients (10 males, 26 females; mean age, 45.3 ± 13.8 years) were enrolled for this study, from April 2015 to January 2016. They underwent quantitative thyroid SPECT/CT 20 minutes post-injection of {sup 99m}Tc-pertechnetate (5 mCi). Association between the time to biochemical euthyroidism after MMI treatment and uptake, standardized uptake value (SUV), functional thyroid mass (SUVmean × thyroid volume) from the SPECT/CT, and clinical/biochemical variables, were investigated. GD patients had a significantly greater %uptake (6.9 ± 6.4%) than historical control euthyroid patients (n = 20, 0.8 ± 0.5%, p < 0.001) from the same quantitative SPECT/CT protocol. Euthyroidism was achieved in 14 patients at 156 ± 62 days post-MMI treatment, but 22 patients had still not achieved euthyroidism by the last follow-up time-point (208 ± 80 days). In the univariate Cox regression analysis, the initial MMI dose (p = 0.014), %uptake (p = 0.015), and functional thyroid mass (p = 0.016) were significant predictors of euthyroidism in response to MMI treatment. However, only uptake remained significant in a multivariate Cox regression analysis (p = 0.034). A uptake cutoff of 5.0% dichotomized the faster responding versus the slower responding GD patients (p = 0.006). A novel parameter of thyroid uptake from quantitative SPECT/CT is a predictive indicator of an early response to MMI in GD patients.

  4. Technetium-99m hexamethylpropylene amine oxime single-photon emission tomography of regional cerebral blood flow in insulin-dependent diabetes

    Energy Technology Data Exchange (ETDEWEB)

    Keymeulen, B. [Dept. of Internal Medicine, Academic Hospital VUB, Brussels (Belgium); Metz, K. de [Dept. of Nuclear Medicine, Academic Hospital VUB, Brussels (Belgium); Cluydts, R. [Dept. of Psychology, Academic Hospital VUB, Brussels (Belgium); Bossuyt, A. [Dept. of Nuclear Medicine, Academic Hospital VUB, Brussels (Belgium); Somers, G.

    1996-02-01

    The study was performed to investigate subclinical abnormalities in regional cerebral blood flow (rCBF) in patients with insulin-dependent diabetes mellitus (IDDM) and to correlate them with patients` characteristics. After intravenous injection of technetium-99m hexamethylpropylene amine oxime (HMPAO), tracer uptake of the prefrontal, frontal and parieto-occipital zones was measured with a triple-head single-photon emission tomography (SPET) camera system in 35 IDDM patients outside an episode of hypolycaemia. Tracer uptake values in 16 age- and sex-matched healthy volunteers served as reference values. Compared with healthy subjects, increased tracer uptake of both prefrontal regions and the left frontal region could be shown in diabetes. Tracer uptake was negatively correlated with the duration of diabetes in all investigated regions. In diabetic patients with a disease duration of more than 5 years (n=26), stepwise regression analysis revealed a significant positive correlation between their HbA1c levels and tracer uptake. Long-term diabetic patients with reduced (pre)frontal tracer uptake (n=8) had lower HbA1c levels than those without (8.4%{+-}0.2% vs 9.3%{+-}0.3%, P<0.05) and tended to have more frequently a history of hypoglycaemic coma (6/8 v 6/18, P=0.06). It can be concluded that duration of diabetes contributes to subclinical changes in basal rCBF in IDDM as detected with HMPAO SPET of the brain. The positive correlation between the presence of regional hypoperfusion and lower HbA1c levels in long-term diabetic patients may be interpreted in the light of presumed higher incidence of hypoglycaemia as metabolic control improves. (orig.)

  5. Sensitivity and Specificity of Dual-Isotope 99mTc-Tetrofosmin and 123I Sodium Iodide Single Photon Emission Computed Tomography (SPECT) in Hyperparathyroidism.

    Science.gov (United States)

    Sommerauer, Michael; Graf, Carmen; Schäfer, Niklaus; Huber, Gerhard; Schneider, Paul; Wüthrich, Rudolf; Schmid, Christoph; Steinert, Hans

    2015-01-01

    Despite recommendations for 99mTc-tetrofosmin dual tracer imaging for hyperparathyroidism in current guidelines, no report was published on dual-isotope 99mTc-tetrofosmin and 123I sodium iodide single-photon-emission-computed-tomography (SPECT). We evaluated diagnostic accuracy and the impact of preoperative SPECT on the surgical procedures and disease outcomes. Analysis of 70 consecutive patients with primary hyperparathyroidism and 20 consecutive patients with tertiary hyperparathyroidism. Imaging findings were correlated with surgical results. Concomitant thyroid disease, pre- and postoperative laboratory measurements, histopathological results, type and duration of surgery were assessed. In primary hyperparathyroidism, SPECT had a sensitivity of 80% and a positive predictive value of 93% in patient-based analysis. Specificity was 99% in lesion-based analysis. Patients with positive SPECT elicit higher levels of parathyroid hormone and higher weight of resected parathyroids than SPECT-negative patients. Duration of parathyroid surgery was on average, approximately 40 minutes shorter in SPECT-positive than in SPECT-negative patients (89 ± 46 vs. 129 ± 41 minutes, p = 0.006); 86% of SPECT-positive and 50% of SPECT-negative patients had minimal invasive surgery (p = 0.021). SPECT had lower sensitivity (60%) in patients with tertiary hyperparathyroidism; however, 90% of these patients had multiple lesions and all of these patients had bilateral lesions. Dual-isotope SPECT with 99mTc-tetrofosmin and 123I sodium iodide has a high diagnostic value in patients with primary hyperparathyroidism and allows for saving of operation time. Higher levels of parathyroid hormone and higher glandular weight facilitated detection of parathyroid lesion. Diagnostic accuracy of preoperative imaging was lower in patients with tertiary hyperparathyroidism.

  6. Decrease in benzodiazepine receptor binding in a patient with Angelman syndrome detected by iodine-123 iomazenil and single-photon emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Odano, Ikuo [Dept. of Radiology, Niigata Univ. School of Medicine, Niigata (Japan); Anezaki, Toshiharu [Dept. of Neurology, Brain Research Inst., Niigata Univ., Niigata (Japan); Ohkubo, Masaki [Dept. of Radiology, Niigata Univ. School of Medicine, Niigata (Japan); Yonekura, Yoshiharu [Nihon Medi-Physics Co. Ltd., Hyogo (Japan); Onishi, Yoshihiro [Biomedical Imaging Research Center, Fukui Medical School, Fukui (Japan); Inuzuka, Takashi [Dept. of Neurology, Brain Research Inst., Niigata Univ., Niigata (Japan); Takahashi, Makoto [Dept. of Radiology, Niigata Univ. School of Medicine, Niigata (Japan); Tsuji, Shoji [Dept. of Neurology, Brain Research Inst., Niigata Univ., Niigata (Japan)

    1996-05-01

    A receptor mapping technique using iodine-123 iomazenil and single-photon emission tomography (SPET) was employed to examine benzodiazepine receptor binding in a patient with Angelman syndrome (AS). AS is characterized by developmental delay, seizures, inappropriate laughter and ataxic movement. In this entity there is a cytogenic deletion of the proximal long arm of chromosome 15q11-q13, where the gene encoding the GABA{sub A} receptor {beta}3 subunit (GABRB3) is located. Since the benzodiazepine receptor is constructed as a receptor-ionophore complex that contains the GABA{sub A} receptor, it is a suitable marker for GABA-ergic synapsis. To determine whether benzodiazepine receptor density, which indirectly indicates changes in GABA{sub A} receptor density, is altered in the brain in patients with AS, we investigated a 27-year-old woman with AS using {sup 123}I-iomazenil and SPET. Receptor density was quantitatively assessed by measuring the binding potential using a simplified method. Regional cerebral blood flow was also measured with N-isopropyl-p-[{sup 123}]iodoamphetamine. We demonstrated that benzodiazepine receptor density is severely decreased in the cerebellum, and mildly decreased in the frontal and temporal cortices and basal ganglia, a result which is considered to indicate decreased GABA{sub A} receptor density in these regions. Although the deletion of GABRB3 was not observed in the present study, we indirectly demonstrated the disturbance of inhibitory neurotransmission mediated by the GABA{sub A} receptor in the investigated patient. {sup 123}I-iomazenil with SPET was useful to map benzodiazepine receptors, which indicate GABA{sub A} receptor distribution and their density. (orig.)

  7. Measurement of temporal regional cerebral perfusion with single-photon emission tomography predicts rate of decline in language function and survival in early Alzheimer`s disease

    Energy Technology Data Exchange (ETDEWEB)

    Claus, J.J.; Walstra, G.J.M.; Hijdra, A.; Gool, W.A. van [Department of Neurology, Academic Medical Center, University of Amsterdam, Amsterdam (Netherlands); Royen, E.A. van [Department of Nuclear Medicine, Academic Medical Center, University of Amsterdam (Netherlands); Verbeeten, B. Jr. [Department of Radiology, Academic Medical Center, University of Amsterdam (Netherlands)

    1999-03-01

    We determined the relationship between regional cerebral blood flow (rCBF) measured with single-photon emission tomography (SPET) and decline in cognitive function and survival in Alzheimer`s disease. In a prospective follow-up study, 69 consecutively referred patients with early probable Alzheimer`s disease (NINCDS/ADRDA criteria) underwent SPET performed at the time of initial diagnosis using technetium-99m-labelled hexamethylpropylene amine oxime. Neuropsychological function was assessed at baseline and after 6 months and survival data were available on all patients, extending to 5.5 years of follow-up. Lower left temporal (P<0.01) and lower left parietal (P<0.01) rCBF were statistically significantly related to decline in language function after 6 months. The association between left temporal rCBF and survival was also statistically significant (P<0.05) using Cox proportional hazards regression analysis. Performing analysis with quartiles of the distribution, we found a threshold effect for low left temporal rCBF (rCBF<73.7%, P<0.01) and high risk of mortality. In this lowest quartile, median survival time was 2.7 years (follow-up to 5.2 years), compared with 4.4 years in the other quartiles (follow-up to 5.5 years). Kaplan-Meier survival curves showed statistically significant (P<0.05, log rank test) survival curves for the lowest versus other quartiles of left temporal rCBF. All results were unaffected by adjustment for age, sex, dementia severity, duration of symptoms, education and ratings of local cortical atrophy. We conclude that left temporal rCBF predicts decline in language function and survival in patients with early probable Alzheimer`s disease, with a threshold effect of low rCBF and high risk of mortality. (orig.) With 3 figs., 3 tabs., 44 refs.

  8. A technetium-99m hexamethylpropylene amine oxime brain single-photon emission tomography study in adolescent patients with major depressive disorder

    Energy Technology Data Exchange (ETDEWEB)

    Tutus, A. [Department of Nuclear Medicine, Erciyes University School of Medicine, Kayseri (Turkey); Kibar, M. [Department of Nuclear Medicine, Cukurova University School of Medicine, Kayseri (Turkey); Sofuoglu, S.; Basturk, M.; Goenuel, A.S. [Department of Psychiatry, Erciyes University School of Medicine, Kayseri (Turkey)

    1998-06-01

    We have not encountered any brain single-photon emission tomography (SPET) study performed in adolescent depressed patients in the literature. Therefore, we used technetium-99m hexamethylpropylene amine oxime ({sup 99m}Tc-HMPAO) brain SPET in adolescent patients with major depressive disorder (MDD) to examine the possible changes in cerebral perfusion and the possible association between perfusion indices and clinical variables. Fourteen adolescent out-patients (nine females, five males; mean{+-}SD age: 13.11{+-}1.43 years; range: 11-15 years) fulfilling the DSM-IV criteria for MDD and 11 age-matched healthy control subjects (six females, five males; mean{+-}SD age: 13.80{+-}1.60 years; range: 12-15 years) were included in the study. {sup 99}Tc-HMPAO brain SPET was performed twice in the patient group and once in the control group. The first SPET investigation was performed under non-medicated conditions and the second was performed after depressive symptoms had subsided. A relative perfusion index (PI) was calculated as the ratio of regional cortical activity to the whole brain activity. We found significant differences between the PI values of the untreated depressed patients and those of the controls, indicating relatively reduced perfusion in the left anterofrontal and left temporal cortical areas. No significant differences in regional PI values were found between the remitted depressed patients and the controls. Our study suggests that adolescent patients with MDD may have regional cerebral blood flow deficits in frontal regions and a greater anterofrontal right-left perfusion asymmetry compared with normal subjects. The fact that these abnormalities in perfusion indices have a trend toward normal values with symptomatic improvement suggests that they may be state-dependent markers for adolescent MDD. (orig.) With 3 figs., 2 tabs., 37 refs.

  9. Postoperative myocardial infarction documented by technetium pyrophosphate scan using single-photon emission computed tomography: Significance of intraoperative myocardial ischemia and hemodynamic control

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, D.C.; Chung, F.; Burns, R.J.; Houston, P.L.; Feindel, C.M. (Toronto Hospital, Ontario (Canada))

    1989-12-01

    The aim of this prospective study was to document postoperative myocardial infarction (PMI) by technetium pyrophosphate scan using single-photon emission computed tomography (TcPPi-SPECT) in 28 patients undergoing elective coronary bypass grafting (CABG). The relationships of intraoperative electrocardiographic myocardial ischemia, hemodynamic responses, and pharmacological requirements to this incidence of PMI were correlated. Radionuclide cardioangiography and TcPPi-SPECT were performed 24 h preoperatively and 48 h postoperatively. A standard high-dose fentanyl anesthetic protocol was used. Twenty-five percent of elective CABG patients were complicated with PMI, as documented by TcPPi-SPECT with an infarcted mass of 38.0 +/- 5.5 g. No significant difference in demographic, preoperative right and left ventricular function, number of coronary vessels grafted, or aortic cross-clamp time was observed between the PMI and non-PMI groups. The distribution of patients using preoperative beta-adrenergic blocking drugs or calcium channel blocking drugs was found to have no correlation with the outcome of PMI. As well, no significant differences in hemodynamic changes or pharmacological requirements were observed in the PMI and non-PMI groups during prebypass or postbypass periods, indicating careful intraoperative control of hemodynamic indices did not prevent the outcome of PMI in these patients. However, the incidence of prebypass ischemia was 39.3% and significantly correlated with the outcome of positive TcPPi-SPECT, denoting a 3.9-fold increased risk of developing PMI. Prebypass ischemic changes in leads II and V5 were shown to correlate with increased CPK-MB release (P less than 0.05) and tends to occur more frequently with lateral myocardial infarction.

  10. Noninvasive detection of matrix metalloproteinase-9 in atherosclerotic lesions using technetium-99m-labeled single-photon emission computed tomography in vivo.

    Science.gov (United States)

    Wang, Zhongjuan; Deng, Gang; Zhang, Zhuiyang; Huang, Hongbo; Zhao, Yanjun

    2017-04-01

    Previous studies have suggested that matrix metalloproteinase (MMP) inhibitor uptake may offer a precise estimation of MMP activity in atherosclerotic lesions. In this study, we explored the feasibility of noninvasive detection of MMP-9 activity using technetium-99m-labeled matrix metalloproteinase-9 antibody (Tc-McAb) in vivo. ApoE-deficient (ApoE) atherosclerosis mice models (n=10) were induced through a high-cholesterol diet following ligation of their left common carotid artery. After 4 weeks, the models were verified through proton density-weighted and T2-weighted images obtained by MRI. C57BL/6 sham mice (n=8) were used as controls. In addition, normal mice (n=20) were used to characterize blood clearance. After radiolabeled McAb administration, single-photon emission computed tomography (SPECT) was performed. Subsequently, left common carotid arteries were harvested for ex-vivo autoradiograph imaging. Then, morphology and activity assays of MMP-9 were histologically and immunohistochemically examined. MRI showed higher signal intensities in the left common carotid arteries with irregular stenoses in the lumen of blood vessels in atherosclerosis mice models in vivo. Atherosclerotic lesions on left common carotid artery specimens were also clearly visualized using SPECT 2 h after Tc-McAb administration in vivo. Note that the radiochemistry purity of the Tc-McAb used was 85-95%. Biodistribution studies have shown that the clearance of Tc-McAb from blood was rapid. In addition, atherosclerotic lesions were clearly visualized on radioautography film shadows ex vivo. MMP-9 activities within the atherosclerotic lesions were noninvasively detected using Tc-labeled SPECT in vivo.

  11. Liver Function Assessment Using Technetium 99m-Galactosyl Single-Photon Emission Computed Tomography/CT Fusion Imaging: A Prospective Trial.

    Science.gov (United States)

    Okabayashi, Takehiro; Shima, Yasuo; Morita, Sojiro; Shimada, Yasuhiro; Sumiyoshi, Tatsuaki; Sui, Kenta; Iwata, Jun; Iiyama, Tatsuo

    2017-09-11

    The prediction of postoperative liver function remains a largely subjective practice based on CT volumetric analysis. However, future liver volume after a hepatectomy is not the only factor that contributes to postoperative liver function and outcomes. In this prospective trial, 185 consecutive patients who underwent liver operations between 2014 and 2015 were studied. Volumetric and functional rates of remnant liver were measured using technetium 99m-galactosyl human serum albumin single-photon emission computed tomography/CT fusion imaging to evaluate post-hepatectomy remnant liver function. Remnant indocyanine green clearance rate using galactosyl (KGSA) (KGSA × functional rate) was used to predict future remnant liver function. Hepatectomy was considered safe for patients with remnant KGSA values ≥0.05, and the primary end point was to determine the accuracy and reliability of this criteria. The prediction of the 90-day major complication and mortality rates was assessed. Median hospital stay was 9 days and median ICU stay was 1 day, with only 1 in-hospital death (90-day mortality rate 0.5%). Overall morbidity rate evaluated according to the Clavien-Dindo classification was 9%. For post-hepatectomy liver failure definitions, the International Study Group of Liver Surgery definition was fulfilled in 14 patients (8%), with the majority being grade B (50%), compared with 2 patients (1%) fulfilling the "50-50" criteria, and 0 patients (0%) fulfilling the PeakBili >7 criteria. Results of this study showed that remnant KGSA provided information that allowed us to predict remnant liver function. This information will be important for surgeons when deciding on a treatment plan for patients with liver diseases. (ClinicalTrials.gov ID: NCT02013895). Copyright © 2017 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  12. Detection of Dose Response in Chronic Doxorubicin-Mediated Cell Death with Cardiac Technetium 99m Annexin V Single-Photon Emission Computed Tomography

    Directory of Open Access Journals (Sweden)

    Kathleen L. Gabrielson

    2008-05-01

    Full Text Available The aim of this study was to evaluate whether technetium 99m hydrazinonicotinamide (99mTc-HYNIC-annexin V single-photon emission computed tomography (SPECT would detect dose-dependent doxorubicin (DOX-mediated cell death in the heart compared with functional echocardiography. Adult female Sprague-Dawley rats were treated with DOX (cumulative dose of 15 or 7.5 mg/kg or saline (n = 7 and monitored by echocardiography. Rats were injected with 7 to 8 mCi 99mTc-HYNIC-annexin V and imaged 1 hour postinjection using a small animal dual-head SPECT/computed tomography (CT system with multipinhole technology. Two regions of interest were drawn in the myocardium and soft tissue regions to calculate the cardiac uptake ratio (CUR of reconstructed images. Myocardium and blood were harvested for radioactivity measurements or TUNEL assay. Biodistribution of 99mTc-HYNIC-annexin V uptake, CUR from SPECT/CT fused cardiac images, and TUNEL of myocardium demonstrated a dose-dependent toxicity response, with the cumulative 15 mg/kg DOX treatment showing the greatest degree of cell death. In contrast, echocardiography detected functional deficits only at the highest DOX dose. In vivo molecular imaging of DOX-induced cardiac toxicity with 99mTc-HYNIC-annexin V detects dose-dependent cell death before ventricular deficits are observed with echocardiography. 99mTc-HYNIC-annexin V SPECT-based molecular imaging may provide an attractive new technique for assessing early changes in myocardial function in patients undergoing DOX therapy.

  13. Regadenoson-stress myocardial CT perfusion and single-photon emission CT: rationale, design, and acquisition methods of a prospective, multicenter, multivendor comparison.

    Science.gov (United States)

    Cury, Ricardo C; Kitt, Therese M; Feaheny, Kathleen; Akin, Jamie; George, Richard T

    2014-01-01

    Pharmacologic stress myocardial CT perfusion (CTP) has been reported to be a viable imaging modality for detection of myocardial ischemia compared with single-photon emission CT (SPECT) in several single-center studies. However, regadenoson-stress CTP has not previously been compared with SPECT in a multicenter, multivendor study. The rationale and design of a phase 2, randomized, cross-over study of regadenoson-stress myocardial perfusion imaging by CTP compared with SPECT are described herein. The study will be conducted at approximately 25 sites by using 6 different CT scanner models, including 64-, 128-, 256-, and 320-slice systems. Subjects with known/suspected coronary artery disease will be randomly assigned to 1 of 2 imaging procedure sequences; rest and regadenoson-stress SPECT on day 1, then regadenoson-stress CTP and rest CTP/coronary CT angiography (same acquisition) on day 2; or regadenoson-stress CTP and rest CTP/CT angiography on day 1, then rest and regadenoson-stress SPECT on day 2. The prespecified primary analysis examines the agreement rate between CTP and SPECT for detecting or excluding ischemia (≥2 or 0-1 reversible defects, respectively), as assessed by 3 independent blinded readers for each modality. Non-inferiority will be indicated if the lower boundary of the 95% CI for the agreement rate is within 0.15 of 0.78 (the observed agreement rate in the regadenoson pivotal trials). The protocol described herein will support the first evaluation of regadenoson-stress CTP by using multiple scanner types compared with SPECT. Copyright © 2014 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  14. Initial clinical experience with regadenoson, a novel selective A2A agonist for pharmacologic stress single-photon emission computed tomography myocardial perfusion imaging.

    Science.gov (United States)

    Hendel, Robert C; Bateman, Timothy M; Cerqueira, Manuel D; Iskandrian, Ami E; Leppo, Jeffrey A; Blackburn, Brent; Mahmarian, John J

    2005-12-06

    Regadenoson, a selective A2A adenosine receptor agonist, was evaluated for tolerability and effectiveness as a pharmacological stress agent for detecting reversible myocardial hypoperfusion when combined with single-photon emission computed tomography (SPECT). Adenosine and dipyridamole are nonselective adenosine agonists currently used as pharmacologic stressors. Despite proven safety, these agents often cause undesirable side effects and require a continuous infusion. This Phase II, multicenter, open-label trial was conducted in 36 patients who had demonstrated ischemia on a 6-min adenosine SPECT imaging study within the previous 2 to 46 days. Patients received regadenoson as a rapid intravenous bolus dose of 400 microg (n = 18) or 500 microg (n = 18). The radiopharmaceutical was then delivered within one minute. The SPECT images were acquired in a standard manner and uniformly processed at a central laboratory. Regadenoson and adenosine studies were presented in random order and interpreted blindly with a 17-segment model by three observers. Additionally, quantitative analysis was performed with 4D-MSPECT software (University of Michigan, Ann Arbor, Michigan). Overall agreement for the presence of reversible hypoperfusion was 86%. The 400-mug dose was better tolerated. Overall, regadenoson was well-tolerated; side effects (e.g., chest discomfort, flushing, dyspnea) were generally mild in severity and self-limiting. High-grade atrioventricular block and bronchospasm were not observed. Regadenoson is well-tolerated and seems as effective as adenosine for detecting and quantifying the extent of hypoperfusion observed with SPECT perfusion imaging. Phase III clinical trials are now underway, given the promise of regadenoson's reduced side effects and simplicity of bolus administration.

  15. Clinical relevance of single-photon emission computed tomography/computed tomography of the neck and thorax in postablation (131)I scintigraphy for thyroid cancer.

    Science.gov (United States)

    Aide, Nicolas; Heutte, Natacha; Rame, Jean-Pierre; Rousseau, Elise; Loiseau, Cédric; Henry-Amar, Michel; Bardet, Stéphane

    2009-06-01

    In patients with differentiated thyroid carcinoma, postablation (131)I scintigraphy aims to detect residual neck disease and distant metastases, usually found in lungs and bones. New hybrid single-photon emission computed tomography/computed tomography (SPECT-CT) cameras that permit functional and anatomical image fusion may improve its clinical relevance. Our objective was to test the added value of neck and thorax SPECT-spiral CT to whole-body scan (WBS) in postablation (131)I scintigraphy. This was a single-referral-center prospective study with a median follow-up of 21 months. Postablation (131)I WBS and neck and thorax SPECT-CT were performed in 55 consecutive patients treated in 2006. WBS and SPECT-CT data were blindly reviewed, scored negative (benign), positive (malignant), or indeterminate and were correlated to the patient outcome. At patient level, WBS and SPECT-CT were negative in 67 and 78% of patients, positive in 4 and 15%, and indeterminate in 29 and 7%, respectively. Overall, nine patients (16%) presented treatment failure (persistent or recurrent disease) 1-16 months after radioiodine ablation. In the 16 patients with indeterminate WBS, negative SPECT-CT ruled out suspicion of disease in nine of nine patients, and positive SPECT-CT confirmed malignant lesions in four of five patients. Positive SPECT-CT predicted treatment failure better than positive WBS (McNemar's test, P = 0.03). This study demonstrates the complementary role of neck and thorax SPECT-CT to WBS in postablation (131)I scintigraphy. Because SPECT-CT allows one to confirm or to rule out residual disease in most cases where WBS remains indeterminate, we recommend its use when available.

  16. Correlation of uptake patterns on single-photon emission computed tomography/computed tomography (SPECT/CT)and treatment response in patients with knee pain

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Geon; Hwang, Kyung Hoon; Lee, Hae Jin; Kim, Seog Gyun; Lee, Beom Koo [Gachon University Gil Hospital, Incheon (Korea, Republic of)

    2016-06-15

    To determine whether treatment response in patients with knee pain could be predicted using uptake patterns on single-photon emission computed tomography/computed tomography (SPECT/CT) images. Ninety-five patients with knee pain who had undergone SPECT/CT were included in this retrospective study. Subjects were divided into three groups: increased focal uptake (FTU), increased irregular tracer uptake (ITU), and no tracer uptake (NTU). A numeric rating scale (NRS-11) assessed pain intensity. We analyzed the association between uptake patterns and treatment response using Pearson's chi-square test and Fisher's exact test. Uptake was quantified from SPECT/CT with region of interest (ROI) counting, and an intraclass correlation coefficient (ICC) calculated agreement. We used Student' t-test to calculate statistically significant differences of counts between groups and the Pearson correlation to measure the relationship between counts and initial NRS-1k1. Multivariate logistic regression analysis determined which variables were significantly associated with uptake. The FTU group included 32 patients; ITU, 39; and NTU, 24. With conservative management, 64 % of patients with increased tracer uptake (TU, both focal and irregular) and 36 % with NTU showed positive response. Conservative treatment response of FTU was better than NTU, but did not differ from that of ITU. Conservative treatment response of TU was significantly different from that of NTU (OR 3.1; p 0.036). Moderate positive correlation was observed between ITU and initial NRS-11. Age and initial NRS-11 significantly predicted uptake. Patients with uptake in their knee(s) on SPECT/CT showed positive treatment response under conservative treatment.

  17. The effect of imaging time, radiopharmaceutical, full fat milk and water on interfering extra-cardiac activity in myocardial perfusion single photon emission computed tomography.

    Science.gov (United States)

    Peace, Richard A; Lloyd, Jim J

    2005-01-01

    Extra-cardiac activity can interfere with observer interpretation of myocardial perfusion single photon emission computed tomography (SPECT) images. Fatty meals and drinks to reduce interference have been tested; however, a simple study of delayed imaging with (99m)Tc-tetrofosmin and (99m)Tc-sestamibi has not been specifically addressed. The aim was to quantify the effects of imaging time, radiopharmaceutical and oral administration of full fat milk and water on interfering activity. Myocardial perfusion SPECT images were acquired using either tetrofosmin or sestamibi. Patients were imaged at 0.5, 1 or 2 h post-injection (tetrofosmin, 59; sestamibi, 72). Additional groups of patients were imaged either with or without milk (tetrofosmin, 54; sestamibi, 45) and with milk and water (sestamibi, 30). A myocardial region was drawn on the anterior projection and a thin adjacent extra-cardiac region was generated automatically. The count density ratio was calculated and validated with a trial of five observers. A decreasing ratio correlated significantly with observer rank of increasing interference with SPECT image interpretation (r=0.95, P=0.001). The ratio improved significantly as the imaging time increased for both tetrofosmin and sestamibi groups (Pmilk or milk plus water showed no significant improvement against control groups (P > or = 0.2). There was no significant difference between tetrofosmin and sestamibi at any time point (P > or = 0.4). Image interpretation may be improved by delayed imaging for tetrofosmin and sestamibi. However, in contrast with common practice, the administration of milk or water appears to be of no clinical value compared with delayed imaging, and there is no significant difference between interfering activity from tetrofosmin and sestamibi.

  18. Novel Application of Quantitative Single-Photon Emission Computed Tomography/Computed Tomography to Predict Early Response to Methimazole in Graves' Disease.

    Science.gov (United States)

    Kim, Hyun Joo; Bang, Ji-In; Kim, Ji-Young; Moon, Jae Hoon; So, Young; Lee, Won Woo

    2017-01-01

    Since Graves' disease (GD) is resistant to antithyroid drugs (ATDs), an accurate quantitative thyroid function measurement is required for the prediction of early responses to ATD. Quantitative parameters derived from the novel technology, single-photon emission computed tomography/computed tomography (SPECT/CT), were investigated for the prediction of achievement of euthyroidism after methimazole (MMI) treatment in GD. A total of 36 GD patients (10 males, 26 females; mean age, 45.3 ± 13.8 years) were enrolled for this study, from April 2015 to January 2016. They underwent quantitative thyroid SPECT/CT 20 minutes post-injection of 99mTc-pertechnetate (5 mCi). Association between the time to biochemical euthyroidism after MMI treatment and %uptake, standardized uptake value (SUV), functional thyroid mass (SUVmean × thyroid volume) from the SPECT/CT, and clinical/biochemical variables, were investigated. GD patients had a significantly greater %uptake (6.9 ± 6.4%) than historical control euthyroid patients (n = 20, 0.8 ± 0.5%, p < 0.001) from the same quantitative SPECT/CT protocol. Euthyroidism was achieved in 14 patients at 156 ± 62 days post-MMI treatment, but 22 patients had still not achieved euthyroidism by the last follow-up time-point (208 ± 80 days). In the univariate Cox regression analysis, the initial MMI dose (p = 0.014), %uptake (p = 0.015), and functional thyroid mass (p = 0.016) were significant predictors of euthyroidism in response to MMI treatment. However, only %uptake remained significant in a multivariate Cox regression analysis (p = 0.034). A %uptake cutoff of 5.0% dichotomized the faster responding versus the slower responding GD patients (p = 0.006). A novel parameter of thyroid %uptake from quantitative SPECT/CT is a predictive indicator of an early response to MMI in GD patients.

  19. Differentiation of myocardial ischemia and infarction assessed by dynamic computed tomography perfusion imaging and comparison with cardiac magnetic resonance and single-photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Tanabe, Yuki; Kido, Teruhito; Kurata, Akira; Miyagawa, Masao; Mochizuki, Teruhito [Ehime University Graduate School of Medicine, Department of Radiology, Toon, Ehime (Japan); Uetani, Teruyoshi; Kono, Tamami; Ogimoto, Akiyoshi [Ehime University Graduate School of Medicine, Department of Cardiology, Pulmonology, Hypertension and Nephrology, Toon, Ehime (Japan); Soma, Tsutomu [FUJIFILM RI Pharma Co., Ltd., QMS Group, Quality Assurance Department, Tokyo (Japan); Graduate School of Medicine, University of Tokyo, Department of Radiology, Tokyo (Japan); Murase, Kenya [Osaka University Graduate School of Medicine, Department of Medical Physics and Engineering, Division of Medical Technology and Science, Faculty of Health Science, Osaka (Japan); Iwaki, Hirotaka [Ehime University Graduate School of Medicine, Center for Clinical Research Data and Biostatistics, Toon, Ehime (Japan)

    2016-11-15

    To evaluate the feasibility of myocardial blood flow (MBF) by computed tomography from dynamic CT perfusion (CTP) for detecting myocardial ischemia and infarction assessed by cardiac magnetic resonance (CMR) or single-photon emission computed tomography (SPECT). Fifty-three patients who underwent stress dynamic CTP and either SPECT (n = 25) or CMR (n = 28) were retrospectively selected. Normal and abnormal perfused myocardium (ischemia/infarction) were assessed by SPECT/CMR using 16-segment model. Sensitivity and specificity of CT-MBF (mL/g/min) for detecting the ischemic/infarction and severe infarction were assessed. The abnormal perfused myocardium and severe infarction were seen in SPECT (n = 90 and n = 19 of 400 segments) and CMR (n = 223 and n = 36 of 448 segments). For detecting the abnormal perfused myocardium, sensitivity and specificity were 80 % (95 %CI, 71-90) and 86 % (95 %CI, 76-91) in SPECT (cut-off MBF, 1.23), and 82 % (95 %CI, 76-88) and 87 % (95 %CI, 80-92) in CMR (cut-off MBF, 1.25). For detecting severe infarction, sensitivity and specificity were 95 % (95 %CI, 52-100) and 72 % (95 %CI, 53-91) in SPECT (cut-off MBF, 0.92), and 78 % (95 %CI, 67-97) and 80 % (95 %CI, 58-86) in CMR (cut-off MBF, 0.98), respectively. Dynamic CTP has a potential to detect abnormal perfused myocardium and severe infarction assessed by SPECT/CMR using comparable cut-off MBF. (orig.)

  20. Clinical studies of cerebral circulation using single photon emission computed tomography, 2; Evaluation of cerebral blood flow after acetazolamide loading on moyamoya disease

    Energy Technology Data Exchange (ETDEWEB)

    Uno, Toshiro [Gifu Univ. (Japan). Faculty of Medicine

    1993-09-01

    To evaluate cerebral blood flow (CBF) in patients with moyamoya disease, single photon emission computed tomography (SPECT) was performed using acetazolamide-activated {sup 133}Xe inhalation method. In the present investigation, 15 patients were subjected: 6 pediatric cases with the mean age of 10.8 years and 9 adult cases with the mean age of 44.6 years. The regional CBF (rCBF) was measured in the territory of anterior cerebral artery (ACA), middle cerebral artery (MCA), posterior cerebral artery (PCA), basal ganglia, and cerebellum. Cerebrovascular acetazolamide reactivity was evaluated from the rCBF measured before and after administration of acetazolamide. Namely, cerebrovascular acetazolamide reactivity was expressed as %CBF and calculated as follows: %CBF=100 x (CBF after acetazolamide administration-CBF at rest)/CBF at rest. rCBF in adult patients was decreased in the cerebral hemisphere, while that in childhood was significantly decreased in the territory of ACA. The %CBF after acetazolamide loading was decreased in the territory of ACA and MCA in both adult and childhood. When cerebral %CBF was compared to the cerebellar %CBF, the ratio of cerebral %CBF and cerebellar %CBF resulted in markedly lower in childhood than adult. rCBF and cerebrovascular acetazolamide reactivity were also measured before and after extracranial and intracranial (EC-IC) bypass surgery in three pediatric moyamoya patients. Although rCBF was increased immediately after EC-IC bypass surgery, the cerebrovascular acetazolamide reactivity remained blunted. These results meant that in the pediatric moyamoya patients cerebrovascular acetazolamide reactivity is more blunted than adult moyamoya patients. Also, the cerebral vessels in moyamoya disease were considered to be dilated to their limitation by the blood supplied through the EC-IC bypass and not to be expandable any more by acetazolamide. (author) 45 refs.

  1. Assessment of changes in regional cerebral blood flow in patients with major depression using the [sup 99m]Tc-HMPAO single photon emission tomography method

    Energy Technology Data Exchange (ETDEWEB)

    Yazici, K.; Kapucu, Oe.; Erbas, B.; Varoglu, E.; Guelec, C.; Bekdik, C.F. (Hacettepe Univ., Ankara (Turkey). Dept. of Nuclear Medicine Hacettepe Univ., Ankara (Turkey). Dept. of Psychiatry)

    1992-12-01

    Regional cerebral blood flow was investigated in 14 patients with major depression diagnosed according to the DSM-III-R criteria (six patients with single and eight patients with recurrent episodes) and in ten healthy volunteers. The mean ages of the patients and the controls were 33.5[+-]2.7 and 31.6[+-]2.6 years, respectively. The severity of the depression was assessed using the 17-item Hamiltonian Depression Scale (mean: 23.2[+-]1.5). None of the patients was under medication. After administration of 500 MBq technetium-99m hexamethylpropylene amine oxime, a single photon emission tomography study was performed and then transaxial, sagittal and coronal slices were obtained. For the semiquantitative analysis of the data, the ratios of the mean counts/pixel to the whole slice were calculated for 24 regions on three consecutive transaxial slices in the orbitomeatal plane. Additionally, left/right and frontal/occipital ratios were calculated. Both sides of the temporal region had a significantly decreased cerebral blood flow (CBF) when compared to the controls. The left/right ratio of the prefrontal region was also significantly lower in the patients than in the controls. The Hamilton score had a negative correlation with blood flow in the anterofrontal and left prefrontal regions. According to our results, regional CBF seems to be decreased in the left prefrontal and in both temporal regions in major depression. The severity of depression is correlated with the reduction in CBF in the regions of the anterofrontal and left prefrontal cortex. (orig.).

  2. Redistribution in I-123 N-isopropyl-p iodoamphetamine single-photon emission computed tomography in cerebrovascular disease and the effects of rehabilitation

    Energy Technology Data Exchange (ETDEWEB)

    Fukumitsu, N.; Kawakami, G.; Uchiyama, M.; Mori, Y. [Dept. of Radiology, Jikei University School of Medicine, Tokyo (Japan); Ogi, S. [Dept. of Radiology, Ichikawa Hospital of Tokyo Dental University, Tokyo (Japan); Takehara, I.; Miyano, S. [Dept. of Rehabilitation Medicine, Jikei Daisan Hospital (Japan); Katagiri, N. [Dept. of Rehabilitation Medicine, Kanagawa Rehabilitation Centre (Japan)

    2001-06-01

    We performed N-isopropyl-p (I-123) iodoamphetamine (IMP) single-photon emission computed tomography (SPECT) on 28 patients with severe cerebrovascular disease before rehabilitation, and compared the degree of redistribution and the assessment of activities of daily living (ADL). We calculated a redistribution (RD) ratio in the central and peripheral parts of the lesions: RD ratio (c) and RD ratio (p). We classified the patients into four groups based on the degree of redistribution: complete: both RD ratio (c) and (p) {>=} 75; peripheral: RD ratio (c) < 75, RD ratio (p) {>=} 75; incomplete: both RD ratio (c) and (p) < 75 and at least one of RD ratio (c) or (p) {>=} 25; no redistribution: both RD ratio (c) and (p) < 25. We assessed the ADL using the modified Barthel index (BI). {delta}BI was defined as BI after rehabilitation-BI before rehabilitation (BIpost-BIpre). The {delta}BI of the four groups were as follows: complete-redistribution group (40.8 {+-} 22.8), peripheral-redistribution group (40.0 {+-} 15.8), incomplete-redistribution group (27.2 {+-} 22.6), no-redistribution group (8.8 {+-} 12.3). The {delta}BI of the complete and peripheral redistribution groups were significantly higher than that of the no-redistribution group. However, {delta}BI was almost the same in the complete- and peripheral-redistribution groups. This suggests that the effect of rehabilitation might be closely related to the viability of the peripheral part of the lesion. (orig.)

  3. Pre-targeted immunodetection in glioma patients: tumour localization and single-photon emission tomography imaging of [[sup 99m]Tc ]PnAO-biotin

    Energy Technology Data Exchange (ETDEWEB)

    Paganelli, G. (INB-CNR, Milan Univ. (Italy). Dept. of Nuclear Medicine Scientific Inst. H San Raffaele, Milan (Italy)); Magnani, P. (INB-CNR, Milan Univ. (Italy). Dept. of Nuclear Medicine Scientific Inst. H San Raffaele, Milan (Italy)); Zito, F. (INB-CNR, Milan Univ. (Italy). Dept. of Nuclear Medicine Scientific Inst. H San Raffaele, Milan (Italy)); Lucignani, G. (INB-CNR, Milan Univ. (Italy). Dept. of Nuclear Medicine Scientific Inst. H San Raffaele, Milan (Italy)); Sudati, F. (INB-CNR, Milan Univ. (Italy). Dept. of Nuclear Medicine Scientific Inst. H San Raffaele, Milan (Italy)); Truci, G. (Div. of Neurology, Milan Univ. (Italy) Scientific Inst. H San Raffaele, Milan (Italy)); Motti, E. (Div. of Neurosurgery, Milan Univ. (Italy) Scientific Inst. H San Raffaele, Milan (Italy)); Terreni, M. (Dept. of Pathology, Scientific Inst. H San Raffaele, Milan (Italy)); Pollo, B. (Dept. of Pathology, Scientific Inst. G. Besta, Milan (Italy)); Giovanelli, M. (Div. of Neurosurgery, Milan

    1994-04-01

    We have developed a three-step pre-targeting method using the avidin-biotin system. The rationale of this technique consists in vivo labelling of biotinylated MoAbs targeted onto tumour deposits, when most of the unbound antibodies have been cleared from the bloodstream as avidin-bound complexes. The anti-tenascin MoAb BC2, specific for the majority of gliomas, was biotinylated and 1 mg was administered i.v. in 20 patients with histologically documented cerebral lesions. After 24-36 h, 5 mg avidin was injected i.v. followed 24 h later by a third i.v. injection of 0.2 mg PnAO-biotin labelled with 15-20 mCi technetium-99m. No evidence of toxicity was observed. Whole-body biodistribution was measured at 20 min, 3 h and 5 h post-injection. [[sup 99m]Tc]PnAO-biotin had a fast blood clearance and was primarily excreted through the biliary system. A dedicated single-photon emission tomography system was used to acquire brain tomographic images 1-2 h after the administration of [[sup 99m]Tc]PnAO-biotin. Tumours were detected in 15/18 glioma patients with a tumour to non-tumour ratio of up 14:1. This three-step method, based on the sequential adminsitration of anti-tenascin MoAb BC2, avidin and [[sup 99m]Tc]PnAO-biotin, can support computed tomography or magnetic resonance imaging for the diagnosis and follow-up of patients with glioma. (orig./MG)

  4. Non-invasive evaluation of myocardial reperfusion by transthoracic Doppler echocardiography and single-photon emission computed tomography in patients with anterior acute myocardial infarction

    Directory of Open Access Journals (Sweden)

    Celutkiene Jelena

    2011-05-01

    Full Text Available Abstract Background The study was designed to evaluate whether the preserved coronary flow reserve (CFR 72 hours after reperfused acute myocardial infarction (AMI is associated with less microvascular dysfunction and is predictive of left ventricular (LV functional recovery and the final infarct size at follow-up. Methods In our study, CFR was assessed by transthoracic Doppler echocardiography (TDE in 44 patients after the successful percutaneous coronary intervention during the acute AMI phase. CFR was correlated with contractile reserve assessed by low-dose dobutamine echocardiography and with the total perfusion defect measured by single-photon emission computed tomography 72 hours after reperfusion and at 5 months follow-up. The ROC analysis was performed to determine test sensitivity and specificity based on CFR. Categorical data were compared by an χ2 analysis, continuous variables were analysed with the independent Student's t test. In order to analyse correlation between CFR and the parameters of LV function and perfusion, the Pearson correlation analysis was conducted. The linear regression analysis was used to assess the relationship between CFR and myocardial contractility as well as the final infarct size. Results We estimated the CFR cut-off value of 1.75 as providing the maximal accuracy to distinguish between patients with preserved and impaired CFR during the acute AMI phase (sensitivity 91.7%, specificity 75%. Wall motion score index was better in the subgroup with preserved CFR as compared to the subgroup with reduced CFR: 1.74 (0.29 vs. 1.89 (0.17 (p Conclusion The early measurement of CFR by TDE can be of high value for the assessment of successful reperfusion in AMI and can be used to predict LV functional recovery, myocardial viability and the final infarct size.

  5. Diagnostic imaging of dementia with Lewy bodies by susceptibility-weighted imaging of nigrosomes versus striatal dopamine transporter single-photon emission computed tomography: a retrospective observational study

    Energy Technology Data Exchange (ETDEWEB)

    Kamagata, Koji; Sato, Kanako; Suzuki, Michimasa; Hori, Masaaki; Kumamaru, Kanako K.; Aoki, Shigeki [Juntendo University Graduate School of Medicine, Department of Radiology, Bunkyo-ku, Tokyo (Japan); Nakatsuka, Tomoya; Inaoka, Tsutomu; Terada, Hitoshi [Toho University Sakura Medical Center, Department of Radiology, Sakura, Sakura (Japan); Sakakibara, Ryuji; Tsuyusaki, Yohei [Toho University Sakura Medical Center, Department of Neurology, Sakura, Sakura (Japan); Takamura, Tomohiro [University of Yamanashi, Department of Radiology, Chuo-shi, Yamanashi (Japan)

    2017-01-15

    The characteristics of dementia with Lewy bodies (DLB), Alzheimer's disease (AD) and amnestic mild cognitive impairment (a-MCI) overlap but require different treatments; therefore, it is important to differentiate these pathologies. Assessment of dopamine uptake in the striatum using dopamine transporter (DaT) single-photon emission computed tomography (SPECT) is the gold standard for diagnosing DLB; however, this modality is expensive, time consuming and involves radiation exposure. Degeneration of the substantia nigra nigrosome-1, which occurs in DLB, but not in AD/a-MCI, can be identified by 3T susceptibility-weighted imaging (SWI). Therefore, the aim of this retrospective observational study was to compare SWI with DaT-SPECT for differentiation of DLB from AD/a-MCI. SWI data were acquired for patients with clinically diagnosed DLB (n = 29), AD (n = 18), a-MCI (n = 13) and healthy controls (n = 26). Images were analysed for nigrosome-1 degeneration. Diagnostic accuracy was evaluated for DLB, AD and a-MCI compared with striatal dopamine uptake using DaT-SPECT. SWI achieved 90% diagnostic accuracy (93% sensitivity, 87% specificity) for the detection of nigrosome-1 degeneration in DLB and not in AD/a-MCI as compared with 88.3% accuracy (93% sensitivity, 84% specificity) using DaT-SPECT. SWI nigrosome-1 evaluation was useful in differentiating DLB from AD/a-MCI, with high accuracy. This less invasive and less expensive method is a potential alternative to DaT-SPECT for the diagnosis of DLB. (orig.)

  6. Iodine-123 {alpha}-methyl-l-tyrosine single-photon emission tomography for the visualization of head and neck squamous cell carcinomas

    Energy Technology Data Exchange (ETDEWEB)

    Flamen, P.; Caveliers, V.; Franken, P.R.; Bossuyt, A. [Department of Nuclear Medicine, Academic Hospital, Free University of Brussels (Belgium); Bernheim, N.; Deron, P. [Department of Otorhinolaryngology and Head and Neck Surgery, Academic Hospital, Free University of Brussels (Belgium); Chavatte, K. [Cyclotron Unit, Academic Hospital, Free University of Brussels (Belgium)

    1998-02-01

    The uptake of iodine-123 {alpha}-methyl-l-tyrosine (IMT) in the primary tumours and metastatic lymph nodes of squamous cell carcinoma of the head and neck was examined with single-photon emission tomography (SPET). Eleven patients with biopsy-proven carcinomas were studied prior to any therapeutic action. The evaluation of cervical lymph node involvement was based on the findings of physical examination, computed tomography and magnetic resonance imaging, and in six patients on the histological data relating to tissue samples obtained by fine-needle lymph node aspiration or surgical intervention. SPET imaging was performed 10 min after the injection of 130-170 MBq IMT using a triple-head gamma camera equipped with medium-energy collimators. High-quality IMT SPET depicted the primary tumour in 10 of 11 patients (sensitivity: 91%). Tumours located in the larynx were visualized more clearly than those located in the mouth or oropharynx. The mean tumour-to-background ratio was 2.35 (range: 1.6-3.1) for laryngeal tumours and 1.67 (range: 1.2-2.2) for mouth and oropharyngeal tumours. Metastatic cervical lymph nodes were involved to various degrees in 8 of the 11 patients. Among these eight patients there were 16 sites, nine of which were detected by IMT SPET (sensitivity: 56%). If the IMT SPET findings were recorded per side of the neck, the sensitivity was 64%. Five of the seven missed metastatic lymph nodes were smaller than 15 mm. The mean tumour-to-background ratio of the scintigraphically visualized lymph nodes was 1.81{+-}0.51 (range: 1.39-2.77). Asymmetric physiological submandibular salivary gland IMT uptake led to false-positive lymph node assessment in three patients. This study indicates the potential use of IMT SPET as a metabolic imaging modality in patients with head and neck squamous cell carcinoma. (orig.) With 2 figs., 3 tabs., 15 refs.

  7. The contribution of single photon emission computed tomography in the clinical assessment of Alzheimer type dementia; Apport de la tomographie d'emission monophonique cerebrale dans l'evaluation des demences de type Alzheimer

    Energy Technology Data Exchange (ETDEWEB)

    Boudousq, V.; Collombier, L.; Kotzki, P.O. [Centre Hospitalier Universitaire de Nimes, 30 (France)

    1999-12-01

    Interest of brain single-photon emission computed tomography to support clinical diagnosis of Alzheimer-type dementia is now established. Numerous studies have reported a decreased perfusion in the association cortex of the parietal lobe and the posterior temporal regions. In patients with mild cognitive complaints, the presence of focal hypoperfusion may increase substantially the probability of the disease. In addition, emission tomography emerges as a helpful tool in situation in which there is diagnostic doubt. In this case, the presence of temporo-parietal perfusion deficit associated with hippocampal atrophy on MRI or X-ray computed tomography contributes to diagnostic accuracy. However, some studies suggest that emission tomography may be useful for preclinical prediction of Alzheimer's disease and to predict cognitive decline. (author)

  8. Technetium-99m methylene diphosphonate uptake in the brachialis muscle hematoma in a patient with prostate cancer and coagulation disorder mimicking bone metastasis evaluated by single-photon emission tomography-computed tomography/computed tomography.

    Science.gov (United States)

    Kamaleshwaran, Koramadai Karuppusamy; Mohanan, Vyshakh; Madhavan, Devdas; Shinto, Ajit Sugunan

    2013-10-01

    We report a case of 79-year-old male with prostate cancer and coagulation disorder presented with left shoulder pain. He underwent bone scintigraphy to rule out metastasis, which showed intense foci of tracer activity in the left axilla. Hybrid single-photon emission tomography-computed tomography (SPECT/CT) of the shoulder region localized tracer uptake to the left brachialis muscle hematoma.

  9. Growth and characterization of InP/In{sub 0.48}Ga{sub 0.52}P quantum dots optimized for single-photon emission

    Energy Technology Data Exchange (ETDEWEB)

    Ugur, Asli

    2012-08-28

    In this work the growth of self-assembled InP/InGaP quantum dots, as well as their optical and structural properties are presented and discussed. The QDs were grown on In{sub 0.48}Ga{sub 0.52}P, lattice matched to GaAs. Self-assembled InP quantum dots are grown using gas-source molecular beam epitaxy over a wide range of InP deposition rates, using an ultra-low growth rate of about 0.01 atomic monolayers/s, a quantum-dot density of 1 dot/μm{sup 2} is realized. The resulting isolated InP quantum dots are individually characterized without the need for lithographical patterning and masks on the substrate. Both excitonic and biexcitonic emissions are observed from single dots, appearing as doublets with a fine-structure splitting of 320 μeV. Hanbury Brown-Twiss correlation measurements for the excitonic emission under cw excitation show anti-bunching behavior with an autocorrelation value of g{sup (2)}(0)=0.2. This system is applicable as a single-photon source for applications such as quantum cryptography. The formation of well-ordered chains of InP quantum dots on GaAs (001) substrates by using self-organized In{sub 0.48}Ga{sub 0.52}P surface undulations as a template is also demonstrated. The ordering requires neither stacked layers of quantum dots nor substrate misorientation. The structures are investigated by polarization-dependent photoluminescence together with transmission electron microscopy. Luminescence from the In{sub 0.48}Ga{sub 0.52}P matrix is polarized in one crystallographic direction due to anisotropic strain arising from a lateral compositional modulation. The photoluminescence measurements show enhanced linear polarization in the alignment direction of quantum dots. A polarization degree of 66% is observed. The optical anisotropy is achieved with a straightforward heterostructure, requiring only a single layer of QDs.

  10. Syndrome of diminished vasodilator reserve of the coronary microcirculation (microvascular angina or syndrome X): Diagnosis by combined atrial pacing and thallium 201 imaging--a case report

    Energy Technology Data Exchange (ETDEWEB)

    Magarian, G.J.; Palac, R.; Reinhart, S. (Veterans Administration Medical Center, Portland, OR (USA))

    1990-08-01

    Patients with angina-like chest pain without evidence of epicardial coronary artery disease or coronary arterial vasospasm are becoming increasingly recognized. These are often related to noncardiac causes including esophageal, musculoskeletal, and hyperventilatory or panic states. However, recently a subgroup of such patients are being recognized as having true myocardial ischemia and chest pain on the basis of diminished coronary microvascular vasodilatory reserve (microvascular ischemia or Syndrome X). The authors describe such a patient who was found to have replication of anginal pain associated with a reversible ischemic defect on thallium 201 imaging during atrial pacing, suggesting ischemia in this myocardial segment. Resolution of angina and ST segment electrocardiographic changes of ischemia occurred with cessation of pacing. We believe this is the first report of a patient with this form of myocardial ischemia diagnosed by this method and should be considered in patients with anginal chest pain after significant coronary artery disease and coronary vasospasm have been excluded.

  11. Effects of low-dose dobutamine on left ventricular function in normal subjects as assessed by gated single-photon emission tomography myocardial perfusion studies

    Energy Technology Data Exchange (ETDEWEB)

    Everaert, H.; Vanhove, C.; Franken, P.R. [Div. of Nuclear Medicine, University Hospital, Free University of Brussels (Belgium)

    1999-10-01

    Electrocardiography gated single-photon emission tomography (gated SPET) allows the assessment of regional perfusion and function simultaneously and in full spatial congruency. In this study changes in global and regional left ventricular function in response to dobutamine infusion were assessed in ten healthy volunteers using sequential gated SPET myocardial perfusion acquisitions. Four consecutive gated SPET images were recorded 60 min after injection of 925 MBq technetium-99m tetrofosmin on a three-head camera equipped with focussing collimators. Two acquisitions were made at rest (baseline 1 and 2), and the third and fourth acquisitions were started 5 min after the beginning of the infusion of 5 and 10 {mu}g kg{sup -1} min{sup -1} dobutamine, respectively. Systolic wall thickening (WT) was quantified using a method based on circumferential profile analysis. Left ventricular ejection fraction (LVEF) and volumes were calculated automatically using the Cedars-Sinai program. Nine of the ten subjects presented a definite increase in WT during dobutamine infusion. WT increased on average from 46%{+-}14% at baseline to 71%{+-}23% (range: 37%-106%; P<0.05) during 5 {mu}g kg{sup -1} min{sup -1} dobutamine infusion and to 85%{+-}25% (range: 62%-123%; P<0.05 with respect to WT at 5 {mu}g kg{sup -1} min{sup -1}) during 10 {mu}g kg{sup -1} min{sup -1} dobutamine infusion. Apical segments showed the largest WT at baseline. The average WT response to dobutamine was similar for all parts of the myocardium. It is concluded that changes in WT induced by infusion of low-dose dobutamine can be assessed by sequential gated SPET myocardial perfusion studies. The ''stress gated SPET'' protocol proposed in this study might be helpful to distinguish viable from scar tissue in patients with coronary artery disease, by demonstrating a preserved inotropic response in hypoperfused myocardium. (orig.)

  12. The Incremental Prognostic Value of Cardiac Computed Tomography in Comparison with Single-Photon Emission Computed Tomography in Patients with Suspected Coronary Artery Disease.

    Directory of Open Access Journals (Sweden)

    Heesun Lee

    Full Text Available Coronary computed tomographic angiography (CCTA facilitates comprehensive evaluation of coronary artery disease (CAD, including plaque characterization, and can provide additive diagnostic value to single-photon emission computed tomography (SPECT. However, data regarding the incremental prognostic value of CCTA to SPECT remain sparse. We evaluated the independent and incremental prognostic value of CCTA, as compared with clinical risk factors and SPECT.A total of 1,077 patients with suspected CAD who underwent both SPECT and cardiac CT between 2004 and 2012 were enrolled retrospectively. Presence of reversible or fixed perfusion defect (PD and summed stress score were evaluated on SPECT. Presence, extent of coronary atherosclerosis and diameter stenosis (DS were evaluated on CCTA. Plaque composition was categorized as non-calcified, mixed, or calcified according to the volume of calcified component (>130 Hounsfield Units. Patients were followed up for the occurrence of adverse cardiac events including cardiac death, non-fatal myocardial infarction, unstable angina, and late revascularization (>90 days after imaging studies.During follow-up (median 23 months, adverse cardiac events were observed in 71 patients (6.6%. When adjusted for clinical risk factors and SPECT findings, the presence of any coronary plaque, any plaque in ≥3 segments, coronary artery calcium score (CACS ≥400, a plaque ≥50% DS, presence of non-calcified plaque (NCP or mixed plaque (MP, and NCP/MP in ≥2 segments were independent predictors of adverse cardiac events; however, the presence of calcified plaque (CP was not. Conventional CCTA findings, including CACS ≥400 and a plaque ≥50% DS, demonstrated incremental prognostic value over clinical risk factors and SPECT (χ² 54.19 to 101.03; p <0.001. Addition of NCP/MP in ≥2 segments resulted in further significantly improved prediction (χ² 101.03 to 113.29; p <0.001.Comprehensive CCTA evaluation of coronary

  13. [Usefulness of brain single-photon emission computed tomography in differentiation of senile dementia from other diseases for at-home care continuation].

    Science.gov (United States)

    Takayanagi, Hideo

    2013-12-01

    Here, we show that brain single-photon emission computed tomography (SPECT) is a less-invasive method and that its findings are very significant. In the present aging society, the number of patients with dementia continues to increase. According to a recent survey by the Ministry of Health, Labour and Welfare, as of 2012, the number of patients with dementia in the country was approximately 3,050,000, and this number is estimated to rise, as 10% of the population is 65 years or older. It is estimated that the number of patients with dementia will increase to 3,450,000 in 2015, 4,100,000 in 2020, and 4,700,000 in 2025, and that, by 2025, patients with dementia will account for 12.8% of the elderly population. Many remediable conditions have been referred to as dementia in the past, and therefore, accurate diagnosis is important not only for the patient but also for the family. Additionally, in Japan, as for Alzheimer's disease, only medicines that can delay the progress are available. However, it is said that Alzheimer's disease can be prevented with the care of the family and appropriate nourishment, exercise, and sleep. Diagnosis of general dementia begins with an interview of the patient and the family. In addition to a clinical diagnosis, imaging studies are performed; however, an accurate early diagnosis is difficult. A more accurate diagnosis can be obtained by the detection of cerebrovascular lesions, brain tumors, and brain damage using computed tomography (CT) and magnetic resonance imaging (MRI) and additional evaluation of the brain blood flow using SPECT. SPECT evaluation is a grade B-C1 recommendation according to the Dementia Disease Treatment Guidelines 2010, primarily developed by the Japanese Society of Neurology. In SPECT examination, Neurolite (ECD), a radioactive agent that tends to accumulate in the cerebral tissues because of the cerebral blood flow, is injected into the elbow vein with the patient in the supine position, and images are taken

  14. Correlative 99mTc-Labeled Tropane Derivative Single Photon Emission Computer Tomography and Clinical Assessment in the Staging of Parkinson Disease

    Science.gov (United States)

    Shinto, Ajit S.; Antony, Joppy; Kamaleshwaran, Koramadai; Vijayan, Krishnan; Selvan, Arul; Korde, Aruna; Kameshwaran, Mythili; Samuel, Grace

    2014-01-01

    Parkinson's disease (PD) is a progressive neurodegenerative disorder characterized by a selective loss of dopamine in the striatum. Problems remain in the accurate diagnosis of PD. The diagnosis of idiopathic PD is based on the interpretation of clinical signs and symptoms could be incorrect at the time of initial presentation. In vivo imaging of the dopaminergic system has the potential to improve the diagnosis of PD in its early stages. The imaging of dopamine transporter (DAT) with 99mTc-labeled tropane derivative (TRODAT-1) single photon emission computer tomography/computer tomography (SPECT/CT) has been proposed to be a valuable and feasible means of assessment of the integrity of dopamine neurons. The purpose of this study was to investigate the potential usefulness of 99mTc-TRODAT-1 imaging in the evaluation of patients with PD and classify into different stages of the disease. SPECT imaging with 99mTc-TRODAT-1 was conducted in 16 consecutive PD patients (9 men; 7 women) and in 6 age matched healthy volunteers (4 men; 2 women). The images were obtained 3 h after the intra-venous injection of the tracer. Specific uptake in the striatum and its sub-regions, including the putamen and caudate nucleus was calculated and the ratios of specific striatal binding to nonspecific occipital binding were calculated. ANOVA with Dunnett C post-hoc analysis was conducted using SPSS 20. A stepwise reduction in specific striatal uptake of 99mTc-TRODAT-1 with increasing disease severity between healthy control versus Stage I versus Stage II versus Stage III was found in PD patients (i.e., 3.77 vs. 2.56 vs. 1.57 vs. 0.63, P < 0.05). The changes were magnified by measurement of specific putaminal uptake (1.43 vs. 0.79 vs. 0.54 vs. 0.19, P < 0.05) and specific caudate uptake (1.90 vs. 1.47 vs. 0.73 vs. 0.27, P < 0.05). No remarkable adverse reactions were found in either healthy volunteers or PD patients during or after imaging. 99mTc-TRODAT-1 is accurate and widely available

  15. Correlative (99m)tc-labeled tropane derivative single photon emission computer tomography and clinical assessment in the staging of Parkinson disease.

    Science.gov (United States)

    Shinto, Ajit S; Antony, Joppy; Kamaleshwaran, Koramadai; Vijayan, Krishnan; Selvan, Arul; Korde, Aruna; Kameshwaran, Mythili; Samuel, Grace

    2014-09-01

    Parkinson's disease (PD) is a progressive neurodegenerative disorder characterized by a selective loss of dopamine in the striatum. Problems remain in the accurate diagnosis of PD. The diagnosis of idiopathic PD is based on the interpretation of clinical signs and symptoms could be incorrect at the time of initial presentation. In vivo imaging of the dopaminergic system has the potential to improve the diagnosis of PD in its early stages. The imaging of dopamine transporter (DAT) with (99m)Tc-labeled tropane derivative (TRODAT-1) single photon emission computer tomography/computer tomography (SPECT/CT) has been proposed to be a valuable and feasible means of assessment of the integrity of dopamine neurons. The purpose of this study was to investigate the potential usefulness of (99m)Tc-TRODAT-1 imaging in the evaluation of patients with PD and classify into different stages of the disease. SPECT imaging with (99m)Tc-TRODAT-1 was conducted in 16 consecutive PD patients (9 men; 7 women) and in 6 age matched healthy volunteers (4 men; 2 women). The images were obtained 3 h after the intra-venous injection of the tracer. Specific uptake in the striatum and its sub-regions, including the putamen and caudate nucleus was calculated and the ratios of specific striatal binding to nonspecific occipital binding were calculated. ANOVA with Dunnett C post-hoc analysis was conducted using SPSS 20. A stepwise reduction in specific striatal uptake of (99m)Tc-TRODAT-1 with increasing disease severity between healthy control versus Stage I versus Stage II versus Stage III was found in PD patients (i.e., 3.77 vs. 2.56 vs. 1.57 vs. 0.63, P < 0.05). The changes were magnified by measurement of specific putaminal uptake (1.43 vs. 0.79 vs. 0.54 vs. 0.19, P < 0.05) and specific caudate uptake (1.90 vs. 1.47 vs. 0.73 vs. 0.27, P < 0.05). No remarkable adverse reactions were found in either healthy volunteers or PD patients during or after imaging. (99m)Tc-TRODAT-1 is accurate and widely

  16. Nanofabrication of Plasmonic Circuits Containing Single Photon Sources

    OpenAIRE

    Siampour, Hamidreza; Kumar, Shailesh; Bozhevolnyi, Sergey I.

    2017-01-01

    Nanofabrication of photonic components based on dielectric-loaded surface plasmon-polariton waveguides (DLSPPWs) excited by single nitrogen vacancy (NV) centers in nanodiamonds is demonstrated. DLSPPW circuits are built around NV containing nanodiamonds, which are certified to be single-photon emitters, using electron-beam lithography of hydrogen silsesquioxane (HSQ) resist on silver-coated silicon substrates. A propagation length of ~20 {\\mu}m for the NV single-photon emission is measured wi...

  17. Analysis of regional cerebral blood flow and distribution volume in Machado-Joseph disease by iodine-{sup 123}I IMP single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, Tsunemi; Nakajima, Takashi; Fukuhara, Nobuyoshi [National Saigata Hospital, Ohagata, Niigata (Japan)

    2001-09-01

    Machado-Joseph disease (MJD) is an autosomal dominant spinocerebellar ataxia. Its clinical features vary greatly in different generations of the same family. Regional cerebral blood flow (rCBF) and distribution volume (V{sub d}) in the pons, cerebellum, and cerebral cortex were measured in 12 patients with MJD by autoradiography (ARG) and the table look-up (TLU) method of iodine-123 IMP ({sup 123}I-IMP) single photon emission computed tomography (SPECT). Representative cases were as follows: A 46-year-old woman first experienced gait ataxia at age 38. Computed tomography (CT) and magnetic resonance imaging (MRI) showed no atrophy in the pons or cerebellum, but rCBF measured by the {sup 123}I-IMP SPECT ARG method detected hypoperfusion in the pons, and cerebellar vermis and hemisphere. A 76-year-old woman first experienced gait ataxia at age 69. CT and MRI findings showed severe atrophy in the pons, and cerebellar vermis and hemisphere. Moreover, rCBF was decreased in the pons, whereas it was not decreased in the cerebellar vermis and hemisphere. In the pons of patients with MJD, rCBF was markedly decreased regardless of disease severity. Because this SPECT finding for the pons looked like a 'dot', we have called it the 'pontine dot sign'. In the MJD group, rCBF was significantly decreased in the pons (Student's t test, p<0.01) and cerebellar vermis (p<0.05). The V{sub d} was also significantly decreased in the pons (p<0.005) in comparison with that for normal subjects. Pearson's correlation analysis yielded a significant relationship between the rCBF in the pons and age at onset (r=0.578, p<0.05). There was a strong correlation between the V{sub d} for the pons and age at onset (r=0.59, p<0.05). Person's correlation analysis also showed a significant relationship between the V{sub d} in the cerebellar hemispheres and International Cooperative Ataxia Rating Scale (r=0.644, p<0.05). The pontine rCBFs in patients with early onset MJD

  18. Extramedullary pulmonary hematopoiesis causing pulmonary hypertension and severe tricuspid regurgitation detected by {sup 99m} technetium sulfur colloid bone marrow scan and single-photon emission computed tomography/CT

    Energy Technology Data Exchange (ETDEWEB)

    Ali, Syed Zama; Clarke, Michael John; Kannivelu, Anbalagan; Chinchure, Dinesh; Srinivasan, Sivasubramanian [Dept. of Diagnostic Radiology, Khoo Teck Puat Hospital, Singapore (Singapore)

    2014-06-15

    Extramedullary pulmonary hematopoiesis is a rare entity with a limited number of case reports in the available literature only. We report the case of a 66-year-old man with known primary myelofibrosis, in whom a {sup 99m}technetium sulfur colloid bone marrow scan with single-photon emission computed tomography (SPECT)/CT revealed a pulmonary hematopoiesis as the cause of pulmonary hypertension and severe tricuspid regurgitation. To the best of our knowledge, this is the first description of {sup 99m} technetium sulfur colloid SPECT/CT imaging in this rare condition.

  19. Recent Advances for High-Efficiency Sources of Single Photons Based on Photonic Nanowires

    DEFF Research Database (Denmark)

    Gerard, J. M.; Claudon, J.; Munsch, M.

    2012-01-01

    Photonic nanowires have recently been used to tailor the spontaneous emission of embedded quantum dots, and to develop record efficiency single-photon sources. We will present recent developments in this field mainly 1) the observation of a strong inhibition of the spontaneous emission of quantum...... dots in ultrathin photonic wires 2) the control of the linear polarization of the single photons by photonic wires with an elliptical section, 3) the joint observation (unlike-cavity-based devices) of a record high efficiency and pure single photon emission process in a photonic wire single photon...

  20. Myocardial scintigraphy with iodine-123 phenylpentadecanoic acid and thallium-201 in patients with coronary artery disease: a comparative dual-isotope study.

    Science.gov (United States)

    Zimmermann, R; Rauch, B; Kapp, M; Bubeck, B; Neumann, F J; Seitz, F; Stokstad, P; Mall, G; Tillmanns, H; Kübler, W

    1992-01-01

    To characterise the clinical usefulness of serial myocardial scintigraphy with iodine-123 phenylpentadecanoic acid (IPPA) in comparison with thallium-201, dual-isotope investigations were performed in 41 patients with angiographically documented coronary artery disease. Both tracers were administered simultaneously during symptom-limited ergometry. Planar scintigrams were acquired immediately after stress, and delayed imaging was performed after 1 h for IPPA and 4 h for 201Tl. Scintigrams were evaluated both qualitatively and quantitatively using a newly developed algorithm for automated image superposition. Initial myocardial uptake of both tracers was closely correlated (r = 0.75, p or = 75% (IP-PA: 70.0%, 201Tl: 66.3%, P = NS) with identical specificity (69.8%). The number of persistent defects, however, was significantly higher with IPPA (P = 0.021), suggesting that visual analysis of serial IPPA scintigrams may overestimate the presence of myocardial scar tissue. On the other hand, previous Q wave myocardial infarction was associated with a decreased regional IPPA clearance (29% +/- 11% vs 44% +/- 11% in normal myocardium, P IPPA is essentially as sensitive as scintigraphy with 201Tl for the detection of stress-induced perfusion abnormalities. Quantitative analysis of myocardial IPPA kinetics, however, is required for the evaluation of tissue viability.

  1. Myocardial scintigraphy with iodine-123 phenylpentadecanoic acid and thallium-201 in patients with coronary artery disease: A comparative dual-isotope study

    Energy Technology Data Exchange (ETDEWEB)

    Zimmermann, R.; Rauch, B.; Kapp, M.; Neumann, F.J.; Seitz, F.; Kuebler, W. (Heidelberg Univ. (Germany). Dept. of Cardiology); Bubeck, B. (Heidelberg Univ. (Germany). Dept. of Nuclear Medicine); Mall, G. (Heidelberg Univ. (Germany). Dept. of Pathology); Tillmanns, H. (Giessen Univ. (Germany). Dept. of Cardiology); Stokstad, P.

    1992-11-01

    To characterise the clinical usefulness of serial myocardial scintigraphy with iodine-123 phenylpentadecanoic acid (IPPA) in comparison with thallium-201, dual-isotope investigations were performed in 41 patients with angiographically documented coronary artery disease. Both tracers were adminstered simultaneously during symptom-limited ergometry. Planar scintigrams were acquired immediately after stress, and delayed imaging was performed after 1 h for IPPA and 4 h for {sup 201}Tl. Scintigrams were evaluated both qualitatively and quantitatively using a newly developed algorithm for automated image superposition. Initial myocardial uptake of both tracers was closely correlated (r=0.75, p<0.001). Both tracers also revealed a similar sensitivity for the identification of individual coronary artery stenoses {>=}75% (IPPA: 70%, {sup 201}Tl: 66.3%, P=NS) with identical specificity (69.8%). The number of persistent defects, however, was significantly higher with IPPA (P=0.021), suggesting that visual analysis of serial IPPA scintigrams may overestimate the presence of myocardial scar tissue. On the other hand, previous Q wave myocardial infarction was associated with a decreased regional IPPA clearance (29%{+-}11% vs 44%{+-}11% in normal myocardium, P<0.05). The data indicate that serial myocardial scintigraphy with IPPA is essentially as sensitive as scintigraphy with {sup 201}Tl for the detection of stress-induced perfusion abnormalities. Quantitative analysis of myocardial IPPA kinetics, however, is required for the evaluation of tissue viability. (orig.).

  2. Usefulness of thallium-201 myocardial scintigraphy during hyperventilation and accelerated exercise test in patients with vasospastic angina and nearly normal coronary artery

    Energy Technology Data Exchange (ETDEWEB)

    Sueda, Shozo; Mineoi, Kazuaki; Kondou, Tadashi [Takanoko Hospital, Matsuyama, Ehime (Japan)] [and others

    1998-04-01

    The usefulness of thallium-201 ({sup 201}Tl) myocardial scintigraphy was studied in 109 patients with vasospastic angina who had nearly normal coronary arteries (degree of stenosis <50%). Coronary spasm was confirmed by pharmacologic agents in all 109 patients from January 1991 to June 1996. The appearance rate of visual redistribution on {sup 201}Tl myocardial scintigraphy was compared between four groups, 34 patients performing graded bicycle ergometer exercise starting at a work load of 50 W with increments of 25 W every 3 min (Ergo(3) group), 14 patients performing hyperventilation for 5 min (HV(5) group), 31 patients performing bicycle ergometer exercise with increments of 25 W every 1 min after 5 min hyperventilation (HV(5)+Ergo(1) group), and 30 patients at rest (Rest group). The value of the visual redistribution rate on {sup 201}Tl myocardial scintigrams in the HV(5)+Ergo(l) group (65%) was higher than that in the patients of other groups (Ergo(3) 41%, HV(5) 43%, Rest 33%). However, there were no significant differences between the four groups. Stress {sup 201}Tl imaging after hyperventilation and accelerated exercise is useful to disclose ischemic evidence in about two thirds of patients with vasospastic angina and nearly normal coronary arteries, whereas about 40% of patients had visual redistribution on {sup 201}Tl myocardial scintigrams by performing standard procedures. (author)

  3. Serial thallium-201 imaging at rest in patients with unstable and stable angina pectoris: relationship of myocardial perfusion at rest to presenting clinical syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Brown, K.A.; Okada, R.D.; Boucher, C.A.; Phillips, H.R.; Strauss, H.W.; Pohost, G.M.

    1983-07-01

    In order to determine whether there are differences in myocardial perfusion at rest among patients with various unstable and stable angina syndromes, serial thallium-201 imaging was performed at rest in 19 patients presenting with rapidly worsening exertional angina (unstable angina, group A), 12 patients with rest angina alone without exertional symptoms (unstable angina, group B), and 34 patients with chronic stable angina. No patient had an episode of angina within 4 hours of study. Nineteen of 19 (100%) patients in group A demonstrated transient defects compared to only 3 of 12 (25%) patients in group B (p less than 0.0001) and 4 of 34 (12%) stable angina patients (p less than 0.0001). The majority of zones demonstrating transient defects in group A were associated with hypokinesis of the corresponding left ventriculogram segment without associated ECG evidence of previous infarction. There were no significant differences in the frequency of persistent thallium defects, severity of angiographic coronary artery disease, or frequency of regional wall motion abnormalities of myocardial segments supplied by stenotic coronary arteries among the three groups of patients. Transient defects have been shown to reflect reduction in regional coronary blood flow to viable myocardium. Therefore, we conclude that regional resting hypoperfusion of viable myocardium is far more common in patients with exertional unstable angina symptoms than in patients with rest angina alone or chronic stable angina.

  4. High brightness single photon sources based on photonic wires

    DEFF Research Database (Denmark)

    Claudon, J.; Bleuse, J.; Bazin, M.

    2009-01-01

    We present a novel single-photon-source based on the emission of a semiconductor quantum dot embedded in a single-mode photonic wire. This geometry ensures a very large coupling (> 95%) of the spontaneous emission to the guided mode. Numerical simulations show that a photon collection efficiency...... of GaAs and defined by reactive-ion etching....

  5. Correlation of Technetium-99m Macroaggregated Albumin and Yttrium-90 Glass Microsphere Biodistribution in Hepatocellular Carcinoma: A Retrospective Review of Pretreatment Single Photon Emission CT and Posttreatment Positron Emission Tomography/CT.

    Science.gov (United States)

    Haste, Paul; Tann, Mark; Persohn, Scott; LaRoche, Thomas; Aaron, Vasantha; Mauxion, Thibault; Chauhan, Nikhil; Dreher, Matthew R; Johnson, Matthew S

    2017-05-01

    To evaluate whether technetium-99 ((99m)Tc)-labeled macroaggregated albumin (MAA) can predict subsequent yttrium-90 ((90)Y) distribution and imaging response in patients with hepatocellular carcinoma (HCC). Retrospective review was performed of records of 83 patients with HCC who underwent (90)Y glass microsphere radioembolization with (99m)Tc-MAA single photon emission computed tomography (SPECT) and (90)Y positron emission tomography (PET)/CT between January 2013 and December 2014. Images were fused to segment the whole liver normal tissue (WLNT) and the largest tumors. Fused images were reviewed and analyzed for comparison of absorbed dose (AD) to tumors and WLNT as calculated from (99m)Tc-MAA SPECT and from (90)Y PET/CT, subjective imaging comparison of (99m)Tc-MAA SPECT and (90)Y PET for tumors and WLNT, and correlation of tumoral AD with response on follow-up CT. Final analysis included 73 and 63 patients for WLNT and tumor (99m)Tc-MAA/(90)Y correlation, respectively, and 62 patients for AD vs response. (99m)Tc-MAA/(90)Y limit of agreement for each reviewer was viewed as clinically acceptable only for WLNT (-15 to 15 Gy). AD interreviewer variability was clinically acceptable for WLNT but was too broad for tumor. Mean tumor AD for objective response (78%) was 313 Gy vs 234 Gy for nonresponders. No threshold was found between tumor AD and response (P > .1). Catheter mismatch between (99m)Tc-MAA and (90)Y had a direct impact on AD mismatch between the 2 image sets. (99m)Tc-MAA was found to be a poor surrogate to quantitatively predict subsequent (90)Y AD to hepatocellular tumors. (99m)Tc-MAA distribution correlated with (90)Y distribution in the normal hepatic parenchyma. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  6. Enhancement of Single-Photon Sources with Metamaterials

    Science.gov (United States)

    Shalaginov, M. Y.; Bogdanov, S.; Vorobyov, V. V.; Lagutchev, A. S.; Kildishev, A. V.; Akimov, A. V.; Boltasseva, A.; Shalaev, V. M.

    2015-06-01

    Scientists are looking for new, breakthrough solutions that can greatly advance computing and networking systems. These solutions will involve quantum properties of matter and light as promised by the ongoing experimental and theoretical work in the areas of quantum computation and communication. Quantum photonics is destined to play a central role in the development of such technologies due to the high transmission capacity and outstanding low-noise properties of photonic information channels. Among the vital problems to be solved in this direction, are efficient generation and collection of single photons. One approach to tackle these problems is based on engineering emission properties of available single-photon sources using metamaterials. Metamaterials are artificially engineered structures with sub-wavelength features whose optical properties go beyond the limitations of conventional materials. As promising single-photon sources, we have chosen nitrogen-vacancy (NV) color centers in diamond, which are capable to operate stably in a single-photon regime at room temperature in a solid state environment. In this chapter, we report both theoretical and experimental studies of the radiation from a nanodiamond single NV center placed near a hyperbolic metamaterial (HMM). In particular, we derive the reduction of excited-state lifetime and the enhancement of collected single-photon emission rate and compare them with the experimental observations. These results could be of great impact for future integrated quantum sources, especially owing to a CMOS-compatible approach to HMM synthesis.

  7. The use of technetium-99m hexamethylpropylene amine oxime labelled granulocytes with single-photon emission tomography imaging in the detection and follow-up of recurrence of infective endocarditis complicating transvenous endocardial pacemaker

    Energy Technology Data Exchange (ETDEWEB)

    Ramackers, J.M. [Department of Nuclear Medicine, CHU E. Herriot, Lyon (France); Kotzki, P.O. [Department of Nuclear Medicine, CHU Lapeyronie et A. de Villeneuve, Montpellier (France); Couret, I. [Department of Nuclear Medicine, CHU Lapeyronie et A. de Villeneuve, Montpellier (France); Messner-Pellenc, P. [Department of Cardiology, CHU Lapeyronie et A. Villeneuve, Montpellier (France); Davy, J.M. [Department of Cardiology, CHU Lapeyronie et A. Villeneuve, Montpellier (France); Rossi, M. [Department of Nuclear Medicine, CHU Lapeyronie et A. de Villeneuve, Montpellier (France)

    1995-11-01

    In this case report we present a patient with a recurrence of subacute bacterial infectious endocarditis (IE) complicating a transvenous endocardial pacemaker. Technetium-99m hexamethylpropylene amine oxime ({sup 99m}Tc-HMPAO) labelled granulocytes were used for diagnosis and follow-up under medical treatment only, since surgical removal of the pacemaker lead was ruled out because of the general condition of the patient. Single-photon emission tomography (SPET) imaging displayed the active lesion previously suspected on echography. At the end of antibiotic therapy, SPET indicated a favourable disease outcome whereas echocardiographic abnormalities remained nearly unchanged. The medical treatment had eradicated the IE, and the patient did well for more than 1 year thereafter. (orig.)

  8. ⁹⁹mTc-ethyl cysteinate dimer cranial single-photon emission computed tomography and serial cranial magnetic resonance imaging in a girl with isolated sulfite oxidase deficiency.

    Science.gov (United States)

    Huang, Yuan-Ling; Lin, Dar-Shong; Huang, Jon-Kway; Chiu, Nan-Chang; Ho, Che-Sheng

    2012-07-01

    Isolated sulfite oxidase deficiency, a rare autosomal recessive inherited disorder, is easily misdiagnosed as the more common hypoxic-ischemic encephalopathy. A female term infant was diagnosed with isolated sulfite oxidase deficiency. Magnetic resonance imaging at ages 13 days, 2 months, and 10 months indicated diffuse edema with posterior predominance, followed by progressive multicystic encephalomalacia and brain atrophy with relatively sparing of the thalami. Single-photon emission computed tomography using (99m)Tc-ethyl cysteinate dimer at 2 months revealed decreased uptake in the frontal lobes. The characteristic neuroimaging findings in isolated sulfite oxidase deficiency help differentiate it from hypoxic insult. The correct diagnosis is helpful in genetic counseling for parents. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Dynamically unpolarized single-photon source in diamond with intrinsic randomness

    OpenAIRE

    Abe, Naofumi; Mitsumori, Yasuyoshi; Sadgrove, Mark; Edamatsu, Keiichi

    2017-01-01

    Polarization is one of the fundamental properties of light, providing numerous applications in science and technology. While ?dynamically unpolarized? single-photon sources are demanded for various quantum applications, such sources have never been explored. Here we demonstrate dynamically unpolarized single-photon emission from a single [111]-oriented nitrogen- vacancy centre in diamond, in which the single-photon stream is unpolarized, exhibiting intrinsic randomness with vanishing polariza...

  10. Detection of perfusion abnormalities in patients with permanent pacemakers on stress-rest 99mTc-tetrofosmin myocardial perfusion single-photon emission computed tomography: comparison between right ventricular apex and right ventricular outflow tract pacing.

    Science.gov (United States)

    Das, Kalpa J; Patel, Chetan D; Sharma, Gautam; Naik, Nitish; Singh, Harmandeep

    2016-04-01

    The aim of the study was to compare the myocardial perfusion defects in patients with right ventricular outflow tract (RVOT) and right ventricular apex (RVA) pacing on stress-rest Tc-tetrofosmin myocardial perfusion single-photon emission computed tomography. A total of 31 patients with permanent pacemakers (RVOT: 16 and RVA: 15) underwent stress-rest Tc-tetrofosmin involving a 1-day protocol. All patients underwent 1-day low-dose stress-gated and high-dose rest-gated Tc-tetrofosmin myocardial perfusion single-photon emission computed tomography imaging. Fixed perfusion defects were noted in 13 (42%) of 31 patients. Two (13%) patients of the RVOT group and 11 (69%) patients of the RVA group showed fixed perfusion defects (P=0.003). The fixed perfusion defects were located in the anteroapical, anteroseptal, and apical in the RVOT pacing group and in the apical, distal anteroseptal, inferoapical, distal anterior, and distal inferoseptal in the RVA pacing group. On univariate analysis, the incidence of perfusion defects was significantly associated with apical pacing, longer pQRS duration, and higher percentage of ventricular pacing. On multivariate analysis, the site of pacemaker insertion was found to be the most important pacemaker parameter determining the incidence of perfusion defects. Importantly, the duration of postpacemaker implantation did not show any significant relation to the incidence of perfusion defects. Fixed perfusion abnormalities are observed in patients with pacemakers and are independent of duration of time since implantation. RVOT pacing is associated with fewer incidences of myocardial perfusion abnormalities compared with RVA pacing.

  11. Simultaneous dual myocardial imaging with iodine-123-[beta]-methyl iodophenyl-pentadecanoic acid (BMIPP) and thallium-201 in patients with coronary heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Tawarahara, Kei; Kurata, Chinori; Taguchi, Takahisa; Aoshima, Shigeyuki; Okayama, Kenichi; Kobayashi, Akira; Yamazaki, Noboru; Kaneko, Masao (Hamamatsu Univ. School of Medicine, Shizuoka (Japan))

    1994-02-01

    To assess the clinical value of simultaneous dual myocardial imaging with iodine-123-[beta]-methyl-iodophenyl-pentadecanoic acid ([sup 123]I-BMIPP) and thallium-201 ([sup 201]TL), myocardial imaging was performed at rest and during execise in seven patients with coronary heart disease. When [sup 123]I-BMIPP and [sup 201]Tl images were compared, the initial exercise and resting images agreed 87% and 64%, respectively. In the initial resting images, the regional uptake of [sup 123]I-BMIPP was frequently less than that of [sup 201]Tl. The incidence of exercise-induced reversible defects by [sup 201]Tl in the Tl>BMIPP regions was significantly higher than that in the Tl=BMIPP regions (57% vs 4%, p<0.01) and the incidence of coronary narrowing of more than 90% in the Tl>BMIPP regions was also significantly higher than that in the Tl=BMIPP regions (91% vs 38%, p<0.01). In addition, this disparity (Tl>BMIPP) was found more frequently in regions with abnormal wall motion than in regions with normal wall motion (hypokinetic regions; 68%, severe hypokinetic or akinetic regions; 50%, vs normokinetic regions; 4%, p<0.01). In contrast, the uptake of [sup 123]I-BMIPP correlated closely with that of [sup 201]Tl in normal myocardium and the uptake of both [sup 123]I-BMIPP and [sup 201]Tl was severely reduced in myocardium with severe ischemia during exercise and prior infarction. These results indicate that dual myocardial imaging with [sup 123]I-BMIPP and [sup 201]Tl may provide a unique means of identifying patients with metabolically disturbed myocardium, such as hibernating and stunned myocardium. (author).

  12. Nanofabrication of Plasmonic Circuits Containing Single Photon Sources

    DEFF Research Database (Denmark)

    Siampour, Hamidreza; Kumar, Shailesh; Bozhevolnyi, Sergey I.

    2017-01-01

    Nanofabrication of photonic components based on dielectric loaded surface plasmon polariton waveguides (DLSPPWs) excited by single nitrogen vacancy (NV) centers in nanodiamonds is demonstrated. DLSPPW circuits are built around NV containing nanodiamonds, which are certified to be single-photon...... emitters, using electron-beam lithography of hydrogen silsesquioxane (HSQ) resist on silver-coated silicon substrates. A propagation length of 20 ± 5 μm for the NV single-photon emission is measured with DLSPPWs. A 5-fold enhancement in the total decay rate, and 58% coupling efficiency to the DLSPPW mode...

  13. Efficient Generation of Frequency-Multiplexed Entangled Single Photons

    Science.gov (United States)

    Qiu, Tian-Hui; Xie, Min

    2016-12-01

    We present two schemes to generate frequency-multiplexed entangled (FME) single photons by coherently mapping photonic entanglement into and out of a quantum memory based on Raman interactions. By splitting a single photon and performing subsequent state transfer, we separate the generation of entanglement and its frequency conversion, and find that the both progresses have the characteristic of inherent determinacy. Our theory can reproduce the prominent features of observed results including pulse shapes and the condition for deterministically generating the FME single photons. The schemes are suitable for the entangled photon pairs with a wider frequency range, and could be immune to the photon loss originating from cavity-mode damping, spontaneous emission, and the dephasing due to atomic thermal motion. The sources might have significant applications in wavelength-division-multiplexing quantum key distribution.

  14. Single-photon emission at 1.55 μm from MOVPE-grown InAs quantum dots on InGaAs/GaAs metamorphic buffers

    Science.gov (United States)

    Paul, Matthias; Olbrich, Fabian; Höschele, Jonatan; Schreier, Susanne; Kettler, Jan; Portalupi, Simone Luca; Jetter, Michael; Michler, Peter

    2017-07-01

    By metal-organic vapor-phase epitaxy, we have fabricated InAs quantum dots (QDs) on InGaAs/GaAs metamorphic buffer layers on a GaAs substrate with area densities that allow addressing single quantum dots. The photoluminescence emission from the quantum dots is shifted to the telecom C-band at 1.55 μm with a high yield due to the reduced stress in the quantum dots. The lowered residual strain at the surface of the metamorphic buffer layer results in a reduced lattice mismatch between the quantum dot material and growth surface. The quantum dots exhibit resolution-limited linewidths (mean value: 59 μeV) and low fine-structure splittings. Furthermore, we demonstrate single-photon emission ( g ( 2 ) ( 0 ) = 0.003 ) at 1.55 μm and decay times on the order of 1.4 ns comparable to InAs QDs directly deposited on GaAs substrates. Our results suggest that these quantum dots can not only compete with their counterparts deposited on InP substrates but also constitute an InAs/GaAs-only approach for the development of non-classical light sources in the telecom C-band.

  15. Relative value of thallium-201 and iodine-131 scans in the detection of recurrence or distant metastasis of well differentiated thyroid carcinoma.

    Science.gov (United States)

    Lin, J D; Kao, P F; Weng, H F; Lu, W T; Huang, M J

    1998-07-01

    Radioactive iodine (131I) has been found to be more sensitive and more specific than thallium-201 for the detection of distant metastases and thyroid remnants in the neck in cases of well-differentiated thyroid carcinoma. 201Tl has been deemed particularly useful in localizing metastases or recurrence in patients with a negative 131I scan and abnormal levels of serum thyroglobulin (Tg). This study aimed to: (1) determine the value of 201Tl imaging in localizing metastases or recurrence in patients with well-differentiated thyroid carcinoma, and (2) evaluate the false-positive and false-negative results of 131I and 201Tl scintigraphy. Sixty-two thyroid remnant ablated patients who underwent simultaneous postoperative 201Tl and 131I scans and and serum Tg determinations were evaluated. Fifty patients had papillary thyroid carcinomas and 12 had follicular thyroid carcinomas. 201Tl imaging was performed before the 131I studies. Of the 62 patients who underwent 201Tl imaging studies, 24 were found to have positive results, with local recurrence or distant metastases. Patients with positive results in the 201Tl imaging studies tended to be older, were mor often male, had higher Tg levels and had a higher recurrence rate. Of these 24 patients, ten had negative diagnostic or therapeutic 131I scans. Concurrently, serum Tg levels were less than 5 ng/ml in five of these ten patients. Three patients were deemed false positive by 201Tl scans; one had a parotid tumour, one a periodontal abscess and one lung metastasis. Among the 38 patients with negative 201Tl scans, 11 had positive findings on 131I scans. Three had distant metastases: two with lung metastases and one with bone metastases. Patients with false-positive results on 131I scans included those with biliary tract stones, ovarian cysts, and breast secretion. Of the 27 patients with negative 201Tl and 131I scans, 15 had elevated serum Tg levels. Among these, local recurrence followed by lung metastases was manifested in

  16. Relative value of thallium-201 and iodine-131 scans in the detection of recurrence or distant metastasis of well differentiated thyroid carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Lin Jen-Der; Weng Hsiao-Fen; Lu Wen-Tsoung [Division of Endocrinology and Metabolism, Chang Gung Memorial Hospital (Taiwan, Province of China); Kao Pan-Fu; Huang Miau-Ju [Department of Nuclear Medicine, Chang Gung Memorial Hospital, Taiwan (Taiwan, Province of China)

    1998-07-01

    Radioactive iodine ({sup 131}I) has been found to be more sensitive and more specific than thallium-201 for the detection of distant metastases and thyroid remnants in the neck in cases of well-differentiated thyroid carcinoma. {sup 201}Tl has been deemed particularly useful in localizing metastases or recurrence in patients with a negative {sup 131}I scan and abnormal levels of serum thyroglobulin (Tg). This study aimed to: (1) determine the value of {sup 201}Tl imaging in localizing metastases or recurrence in patients with well-differentiated thyroid carcinoma, and (2) evaluate the false-positive and false-negative results of {sup 131}I and {sup 201}Tl scintigraphy. Sixty-two thyroid remnant ablated patients who underwent simultaneous postoperative {sup 201}Tl and {sup 131}I scans and and serum Tg determinations were evaluated. Fifty patients had papillary thyroid carcinomas and 12 had follicular thyroid carcinomas. {sup 201}Tl imaging was performed before the {sup 131}I studies. Of the 62 patients who underwent {sup 201}Tl imaging studies, 24 were found to have positive results, with local recurrence or distant metastases. Patients with positive results in the {sup 201}Tl imaging studies tended to be older, were mor often male, had higher Tg levels and had a higher recurrence rate. Of these 24 patients, ten had negative diagnostic or therapeutic {sup 131}I scans. Concurrently, serum Tg levels were less than 5 ng/ml in five of these ten patients. Three patients were deemed false positive by {sup 201}Tl scans; one had a parotid tumour, one a periodontal abscess and one lung metastasis. Among the 38 patients with negative {sup 201}Tl scans, 11 had positive findings on {sup 131}I scans. Three had distant metastases: two with lung metastases and one with bone metastases. Patients with false-positive results on {sup 131}I scans included those with biliary tract stones, ovarian cysts, and breast secretion. Of the 27 patients with negative {sup 201}Tl and {sup 131}I

  17. Single photon emission computed tomography procedure improves accuracy of somatostatin receptor scintigraphy in endocrine gastro-entero-pancreatic tumours; Dectection des tumeurs endocrines de l'abdomen: interet de la tomographie et des images planaires

    Energy Technology Data Exchange (ETDEWEB)

    Lebtahi, R.; Genin, R.; Rouzet, F.; Bleicner-Perez, S.; Lievre, A.; Scigliano, S.; Vialle, C.; Le Guludec, D. [Hopital Bichat, Service de Medecine Nucleaire, 75 - Paris (France); Cadiot, G. [Hopital de Reims, Service de Gastro-Enterologie, 51 - Reims (France); Sobhani, I. [Hopital Henri-Mondor, Service de Gastro-Enterologie, 94 - Creteil (France); Mignon, M. [Hopital Bichat, Service de Gastro-Enterologie, 75 - Paris (France)

    2005-05-15

    Somatostatin receptors scintigraphy (SRS) is a sensitive method for the detection of endocrine gastro-entero-pancreatic tumors. The aim of this study was to evaluate the sensitivity of anterior and posterior planar associated to single photon emission computerized tomography (SPECT) compared to anterior and posterior planar associated to additional lateral and oblique views in the detection of abdominal endocrine tumors. One hundred and sixty four patients with endocrine gastro-entero-pancreatic tumors were included in this study. Scintigraphic images were performed after injection of 189 {+-} 23 MBq of {sup 111}In-Pentetreotide. Abdominal planar images were performed 4 h and 24 hours after injection. Abdominal SPECT was performed at 24 hours. The combination of anterior and posterior abdominal planar images with SPECT using iterative reconstruction detected significantly more tumoral sites compared to multiple planar images (298 versus 280 for the liver, p = 0.01 and 90 versus 88 for coeliac area). In particular liver lesions were better delineated on tomographic slices. The combination of {sup 111}In-Pentetreotide SPECT with anterior and posterior planar images is more sensitive than multiple planar images to detect abdominal endocrine tumors. (author)

  18. Single photon emission computed tomography of the brain in Sturge-Weber syndrome using N-isopropyl-p-( sup 123 I) iodoamphetamine; A comparative study with X-ray computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Horita, Hideki; Nozaki, Hidetsugu; Hamano, Shinichiro; Aihara, Toshinori (Saitama Children' s Medical Center, Iwatsuki (Japan))

    1990-07-01

    Single photon emission computed tomography (SPECT) of the brain using N-isopropyl-p-({sup 123}I) iodoamphetamine ({sup 123}I-IMP) was performed in 11 children with port wine stain on the face or head, aged 1.0{approx}14.2 years at investigation. Four cases without neurologic symptoms had no specific abnormality on SPECT and X-ray computed tomography (CT). In 4 cases of so-called Sturge-Weber syndrome with developmental quotients (DQ) or intelligence quotients (IQ) more than 80 and the neurologic symptoms consisting of seizures and hemiplegia, SPECT showed localized reduction of IMP accumulation, and CT exhibited calcification, atrophy and enhancement in 2 cases of 3 with contrast medium infusion in the same areas. In 3 cases with DQ of 50{approx}60 and severer neurologic symptoms, SPECT showed diffuse reduction or defect of IMP accumulation in the ipsilateral hemisphere, and CT exhibited remarkable atrophy, calcifications and enhancement in 2 cases with contrast medium infusion in the same hemisphere. In one case with severe neurologic symptoms, SPECT performed at an early stage showed high IMP accumulation in the ipsilateral hemisphere. (author).

  19. Effects of smoking on myocardial injury in patients with conservatively treated acute myocardial infarction. A study with resting {sup 123}I-15-iodophenyl 3-methyl pentadecanoic acid/{sup 201}Tl myocardial single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yamagishi, Hiroyuki; Akioka, Kaname; Shirai, Naoya; Yoshiyama, Minoru; Teragaki, Masakazu; Takeuchi, Kazuhide; Yoshikawa, Junichi; Ochi, Hironobu [Osaka City Univ. (Japan). Graduate School of Medicine

    2001-09-01

    Many reports have demonstrated that smokers who have suffered an acute myocardial infarction (AMI) have a better prognosis than nonsmokers. The present study investigated the effects of current smoking on myocardial injury with resting {sup 123}I-15-iodophenyl 3-methyl pentadecanoic acid (BMIPP)/{sup 201}Tl myocardial single photon emission computed tomography in 103 patients with conservatively treated AMI. The left ventricular myocardium was divided into 9 segments and BMIPP and {sup 201}Tl defects were scored using a 5-point grading system (0=normal and 4=no uptake). The sum of the defect scores was defined as the total defect score. There was no significant difference in either the baseline severity of the coronary artery discase or the total defect scores for BMIPP and {sup 201}Tl between the current smoker and nonsmoker groups. The difference between the total defect scores for BMIPP and {sup 201}Tl tended to be larger in the current smoker group than in the nonsmoker group (2.0{+-}1.9 vs 1.3{+-}1.6, p=0.056). Forty-one (53%) of 77 patients in the current smoker group exhibited a BMIPP/{sup 201}Tl mismatch, whereas only 8 (31%) of 26 patients in the nonsmoker group did (p=0.047). In conclusion, current smokers had more likelihood of salvageable myocardium in areas at risk, as demonstrated by BMIPP/{sup 201}Tl mismatch, in AMI than nonsmokers. (author)

  20. Single photon emission tomography imaging of myocardial oxidative metabolism with 15-(p-iodophenyl)pentadecanoic acid in patients with coronary artery disease and aorta-coronary bypass graft surgery

    Energy Technology Data Exchange (ETDEWEB)

    Kropp, J.; Reichmann, K.; Biersach, H.J. (Bonn Univ. (Germany, F.R.). Inst. fuer Klinische und Experimentelle Nuklearmedizin); Likungu, J.; Kirchhoff, P.G. (Bonn Univ. (Germany, F.R.). Klinik fuer Herz- und Gefaesschirurgie); Knapp, F.F. Jr. (Oak Ridge National Lab., TN (USA). Nuclear Medicine Group); Reske, S.N. (Technische Hochschule Aachen (Germany, F.R.). Abt. fuer Nuklearmedizin)

    1991-07-01

    A total of 29 patients with coronary artery disease (CAD) were investigated with 15-(p-iodophenyl)-pentadecanoic acid I123 ({sup 123}I-IPPA) and sequential single photon emission tomography (SPET). Of these, 19 were studied after aorto-coronary bypass graft surgery. Some 13 patients without evidence of CAD served as a control group. Two SPET studies (early and late) were carried out within 45 min after intravenous administration of 200 MBq {sup 123}I-IPPA at peak sub-maximal exercise. Semi-quantification of uptake (related to perfusion) and turnover (linked to metabolism) was obtained by segmental comparison of oblique slices. Taking coronary arteriography as the 'gold standard', {sup 123}I-IPPA scintigraphy had the following figures of merit for sensitivity and specificity in the diagnosis of CAD: for the left anterior descending artery territory 93% and 95%, for the left circumflex artery region 96% and 92%, and for the right coronary artery territory 77% and 92%, respectively. In all, 90% of the reperfused myocardial segments showed an improvement of uptake. Of these, 61% exhibited increased turnover after revascularization and 39% had pathologic turnover and thus a dissociation of improvement of perfusion and oxidative metabolism after surgery. (orig.).

  1. Ictal technetium-99 m ethyl cysteinate dimer single-photon emission tomographic findings in epileptic patients with polymicrogyria syndromes: A subtraction of ictal-interictal SPECT coregistered to MRI study

    Energy Technology Data Exchange (ETDEWEB)

    Wichert-Ana, Lauro [University of Sao Paulo, Center for Epilepsy Surgery, Department of Neurology, Psychiatry and Clinical Psychology, Ribeirao Preto (Brazil); Hospital das Clinicas, USP, Centro de Cirurgia de Epilepsia, CIREP, Ribeirao Preto, SP (Brazil); Mazzoncini de Azevedo-Marques, Paulo; Santos, Antonio C.; Araujo, David [University of Sao Paulo, Center for Imaging Science and Medical Physics, Department of Internal Medicine, Ribeirao Preto (Brazil); Ferrari Oliveira, Lucas [Federal University of Pelotas, Informatics Department, Pelotas, RS (Brazil); Fernandes, Regina M.F.; Velasco, Tonicarlo R.; Sakamoto, Americo C. [University of Sao Paulo, Center for Epilepsy Surgery, Department of Neurology, Psychiatry and Clinical Psychology, Ribeirao Preto (Brazil); Kato, Mery [University of Sao Paulo, Division of Nuclear Medicine, Department of Internal Medicine from the Ribeirao Preto Medical School, Ribeirao Preto (Brazil); Muxfeldt Bianchin, Marino [Rio Grande do Sul Federal University, Neurology Division, HCPA, Porto Alegre, RS (Brazil)

    2008-06-15

    To describe the ictal technetium-99 m-ECD SPECT findings in polymicrogyria syndromes (PMG) during epileptic seizures. We investigated 17 patients with PMG syndromes during presurgical workup, which included long-term video-electroencephalographic (EEG) monitoring, neurological and psychiatry assessments, invasive EEG, and the subtraction of ictal-interictal SPECT coregistered to magnetic resonance imaging (MRI) (SISCOM). The analysis of the PMG cortex, using SISCOM, revealed intense hyperperfusion in the polymicrogyric lesion during epileptic seizures in all patients. Interestingly, other localizing investigations showed heterogeneous findings. Twelve patients underwent epilepsy surgery, three achieved seizure-freedom, five have worthwhile improvement, and four patients remained unchanged. Our study strongly suggests the involvement of PMG in seizure generation or early propagation. Both conventional ictal single-photon emission computed tomography (SPECT) and SISCOM appeared as the single contributive exam to suggest the localization of the epileptogenic zone. Despite the limited number of resective epilepsy surgery in our study (n = 9), we found a strong prognostic role of SISCOM in predicting surgical outcome. This result may be of great value on surgical decision-making of whether or not the whole or part of the PMG lesion should be surgically resected. (orig.)

  2. Radiolabeled cyclic arginine-glycine-aspartic (RGD)-conjugated iron oxide nanoparticles as single-photon emission computed tomography (SPECT) and magnetic resonance imaging (MRI) dual-modality agents for imaging of breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Deng, Shengming; Zhang, Wei; Zhang, Bin, E-mail: zbnuclmd@126.com [The First Affiliated Hospital of Soochow University, Department of Nuclear Medicine (China); Hong, Ruoyu [Soochow University, College of Chemistry, Chemical Engineering and Materials Science & Key Laboratory of Organic Synthesis of Jiangsu Province (China); Chen, Qing; Dong, Jiajia [The First Affiliated Hospital of Soochow University, Department of Nuclear Medicine (China); Chen, Yinyiin [The First Affiliated Hospital of Soochow University, Department of Radiology (China); Chen, Zhiqiang; Wu, Yiwei, E-mail: wuyiwei3988@gmail.com [The First Affiliated Hospital of Soochow University, Department of Nuclear Medicine (China)

    2015-01-15

    Ultrasmall superparamagnetic iron oxide nanoparticles (USPIOs) modified with a novel cyclic arginine-glycine-aspartate (RGD) peptide were made and radiolabeled as single-photon emission computed tomography (SPECT) and magnetic resonance imaging (MRI) dual-modality agents for imaging of breast cancer. The probe was tested both in vitro and in vivo to determine its receptor targeting efficacy and feasibility for SPECT and MRI. The radiochemical syntheses of {sup 125}I-cRGD-USPIO were accomplished with a radiochemical purity of 96.05 ± 0.33 %. High radiochemical stability was found in fresh human serum and in phosphate-buffered saline. The average hydrodynamic size of {sup 125}I-cRGD-USPIO determined by dynamic light scattering was 51.3 nm. Results of in vitro experiments verified the specificity of the radiolabeled nanoparticles to tumor cells. Preliminary biodistribution studies of {sup 125}I-radiolabeled cRGD-USPIO in Bcap37-bearing nude mice showed that it had long circulation half-life, high tumor uptake, and high initial blood retention with moderate liver uptake. In vivo tumor targeting and uptake of the radiolabeled nanoparticles in mice model were visualized by SPECT and MRI collected at different time points. Our results strongly indicated that the {sup 125}I-cRGD-USPIO could be used as a promising bifunctional radiotracer for early clinical tumor detection with high sensitivity and high spatial resolution by SPECT and MRI.

  3. Phase analysis of gated myocardial perfusion single-photon emission computed tomography after coronary artery bypass graft surgery: reflection of late reverse remodeling in patients with patent grafts after coronary artery bypass graft surgery.

    Science.gov (United States)

    Park, Sohyun; Cheon, Gi Jeong; Paeng, Jin Chul; Won, Kyoung Sook; Kang, Keon Wook; Kim, Ki-Bong; Chung, June-Key; Lee, Dong Soo

    2016-11-01

    Phase analysis using gated myocardial perfusion single-photon emission computed tomography (GMPS) is a tool used to assess left ventricular (LV) dyssynchrony. We attempted to investigate the role of LV dyssynchrony assessed by GMPS using phase analysis for the late LV function after coronary artery bypass graft surgery (CABG) in patients with patent grafts. A total of 45 patients who received off-pump CABG with patent graft 1 year after CABG and preserved perfusion reserve were enrolled retrospectively. All patients underwent GMPS before and 3 months and 1 year after CABG. Using the Emory Cardiac Toolbox, both phase histogram bandwidth (PBW) and phase SD derived by phase analysis were used for the analysis, in addition to the conventional perfusion parameters. For the evaluation of LV function, transthoracic echocardiography was also performed. All of the patients showed perfusion improvement (paired t-test, Preverse remodeling. Among those patients with reverse remodeling, 19 patients had shown LV 3 months after CABG. Using stepwise logistic regression with forward selection, PBW 3 months after CABG could predict reverse remodeling 1 year after CABG (odds ratio 1.03, Preverse remodeling 1 year after CABG with a cut-off value of 82 (sensitivity 0.95, specificity 0.56, Preverse remodeling and potential of further functional improvement in patients with patent grafts and preserved perfusion reserve after CABG.

  4. Using co-registration of single photon emission computed tomography and magnetic resonance imaging to place an intracranial grid for electrode monitoring, leading to resection of a frontal lobe astrocytoma

    Energy Technology Data Exchange (ETDEWEB)

    Hughes, T.; Barnden, L.; Rowe, C.C. [the Queen Elizabeth Hospital , Adelaide, SA (Australia). Department of Nuclear Medicine

    1998-06-01

    Full text: A 24 year old female had previously been treated with radiotherapy for a low-grade astrocytoma of the left frontal lobe. Despite medication, she had since suffered increasingly frequent partial seizures which dramatically reduced her quality of life. She was assessed for resection of the epileptic focus. Inter-ictal and ictal single photon emission computed tomography (SPECT) were acquired following injections of {sup 99m}Tc HMPAO (CERETEC). Routine image interpretation did not allow confident localization of the seizure focus. However, when these images were superimposed and subtracted, an area of ictal hyperperfusion on the posterior margin of the tumour was identified. The resultant image was co-registered with magnetic resonance imaging (MRI). A subdural electrode grid was implanted over this area and adjacent frontal cortex. Subsequent ictal electroencephalogram (EEG) recordings confirmed that this area was the seizure focus. Local cortical stimulation through the grid indicated that it could be safely resected. Following left frontal lobectomy using margins defined by the subdural grid, the patient has been seizure free and suffered no neurological deficits. This case study is an example of the benefits to be gained by the co-registration of functional and anatomical imaging

  5. Comparison of image uniformity with photon counting and conventional scintillation single-photon emission computed tomography system: A Monte Carlo simulation study

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ho Chul; Lee, Young Jin [Dept. of Radiological Science, Eulji University, Seongnam (Korea, Republic of); Kim, Hee Joung; Kim, Kyuseok; Lee, Min Hee [Yonsei University, Wonju (Korea, Republic of)

    2017-06-15

    To avoid imaging artifacts and interpretation mistakes, an improvement of the uniformity in gamma camera systems is a very important point. We can expect excellent uniformity using cadmium zinc telluride (CZT) photon counting detector (PCD) because of the direct conversion of the gamma rays energy into electrons. In addition, the uniformity performance such as integral uniformity (IU), differential uniformity (DU), scatter fraction (SF), and contrast-to-noise ratio (CNR) varies according to the energy window setting. In this study, we compared a PCD and conventional scintillation detector with respect to the energy windows (5%, 10%, 15%, and 20%) using a {sup 99m}Tc gamma source with a Geant4 Application for Tomography Emission simulation tool. The gamma camera systems used in this work are a CZT PCD and NaI(Tl) conventional scintillation detector with a 1-mm thickness. According to the results, although the IU and DU results were improved with the energy window, the SF and CNR results deteriorated with the energy window. In particular, the uniformity for the PCD was higher than that of the conventional scintillation detector in all cases. In conclusion, our results demonstrated that the uniformity of the CZT PCD was higher than that of the conventional scintillation detector.

  6. Comparison of Image Uniformity with Photon Counting and Conventional Scintillation Single-Photon Emission Computed Tomography System: A Monte Carlo Simulation Study

    Directory of Open Access Journals (Sweden)

    Ho Chul Kim

    2017-06-01

    Full Text Available To avoid imaging artifacts and interpretation mistakes, an improvement of the uniformity in gamma camera systems is a very important point. We can expect excellent uniformity using cadmium zinc telluride (CZT photon counting detector (PCD because of the direct conversion of the gamma rays energy into electrons. In addition, the uniformity performance such as integral uniformity (IU, differential uniformity (DU, scatter fraction (SF, and contrast-to-noise ratio (CNR varies according to the energy window setting. In this study, we compared a PCD and conventional scintillation detector with respect to the energy windows (5%, 10%, 15%, and 20% using a 99mTc gamma source with a Geant4 Application for Tomography Emission simulation tool. The gamma camera systems used in this work are a CZT PCD and NaI(Tl conventional scintillation detector with a 1-mm thickness. According to the results, although the IU and DU results were improved with the energy window, the SF and CNR results deteriorated with the energy window. In particular, the uniformity for the PCD was higher than that of the conventional scintillation detector in all cases. In conclusion, our results demonstrated that the uniformity of the CZT PCD was higher than that of the conventional scintillation detector.

  7. Ictal technetium-99m ethyl cysteinate dimer single-photon emission tomographic findings and propagation of epileptic seizure activity in patients with extratemporal epilepsies

    Energy Technology Data Exchange (ETDEWEB)

    Noachtar, S.; Arnold, S.; Werhahn, K.J. [Department Neurologie, Ludwig-Maximilians Universitaet, Muenchen (Germany); Yousry, T.A. [Muenchen Univ. (Germany). Abt. fuer Neuroradiologie; Bartenstein, P. [Department of Nuclear Medicine, Technical University of Munich, Munich (Germany); Tatsch, K. [Department of Nuclear Medicine, Ludwig-Maximilians University of Munich, Munich (Germany)

    1998-02-01

    We investigated the influence of the propagation of extratemporal epileptic seizure activity on the regional increase in cerebral blood flow, which is usually associated with epileptic seizure activity. Forty-two consecutive patients with extratemporal epilepsies were prospectively evaluated. All patients underwent ictal SPET studies with simultaneous electroencephalography (EEG) and video recordings of habitual seizures and imaging studies including cranial magnetic resonance imaging and positron emission tomography with 2-[{sup 18}F]-fluoro-2 deoxy-d-glucose. Propagation of epilptic seizure activity (PESA) was defined as the absence of hyperperfusion on ictal ECD SPET in the lobe of seizure onset, but its presence in another ipsilateral or contralateral lobe. Observers analysing the SPET images were not informed of the other results. PESA was observed in 8 of the 42 patients (19%) and was ipsilateral to the seizure onset in five (63%) of these eight patients. The time between clinical seizure onset and injection of the ECD tracer ranged from 14 to 61 s (mean 34 s). Seven patients (88%) with PESA had parieto-occipital epilepsy and one patient had a frontal epilepsy. PESA was statistically more frequent in patients with parieto-occipital lobe epilepsies (58%) than in the remaining extratemporal epilepsy syndromes (3%) (P<0.0002). These findings indicate that ictal SPET studies require simultaneous EEG-video recordings in patients with extratemporal epilepsies. PESA should be considered when interpreting ictal SPET studies in these patients. Patients with PESA are more likely to have parieto-occipital lobe epilepsy than seizure onset in other extratemporal regions. (orig./MG) (orig.) With 1 fig., 2 tabs., 23 refs.

  8. A novel high-efficiency single-mode quantum dot single photon source

    DEFF Research Database (Denmark)

    Gerard, J.M.; Gregersen, Niels; Nielsen, Torben Roland

    2008-01-01

    We present a novel single-mode single photon source exploiting the emission of a semiconductor quantum dot (QD) located inside a photonic wire. Besides an excellent coupling (>95%) of QD spontaneous emission to the fundamental guided mode [1], we show that a single photon collection efficiency...... above 80% within a 0.5 numerical aperture can be achieved using a bottom Bragg mirror and a tapering of the nanowire tip. Because this photon collection strategy does not exploit the Purcell effect, it could also be efficiently applied to broadband single photon emitters such as F-centers in diamond....

  9. Single-Photon Technologies Based on Quantum-Dots in Photonic Crystals

    DEFF Research Database (Denmark)

    Lehmann, Tau Bernstorff

    In this thesis, the application of semiconductor quantum-dots in photonic crystals is explored as aresource for single-photon technology.Two platforms based on photonic crystals, a cavity and a waveguide, are examined as platformssingle-photon sources. Both platforms demonstrate strong single......-photons from a quantum-dot are routed on timescalesof the exciton lifetime. Using active demultiplexing a three-fold single-photon state is generated at anextracted rate of 2:03 ±0:49 Hz.An on-chip power divider integrated with a quantum-dot is investigated. Correlation measurementof the photon statistic...... veries the single-photon nature of the quantum-dot. Furthermore correlationmeasurement between the outputs of the power divider conrms the passive separation of the singlephotonemission.A scheme for post-emission entanglement generation between single-photons from an efficientsource is discussed...

  10. {sup 123}I-5-I-R91150, a new single-photon emission tomography ligand for 5-HT{sub 2A} receptors: influence of age and gender in healthy subjects

    Energy Technology Data Exchange (ETDEWEB)

    Baeken, C.; D`haenen, H. [Dept. of Psychiatry, Academic Hospital, Brussels (Belgium); Flamen, P.; Bossuyt, A. [Dept. of Nuclear Medicine, Academic Hospital, Brussels (Belgium); Mertens, J.; Terriere, D.; Chavatte, K.; Boumon, R. [Cyclotron Unit, Free University of Brussels, Brussels (Belgium)

    1998-12-01

    5-HT{sub 2A} receptors have been implicated in the pathophysiology of mood disorders and in the therapeutic effect of the so-called atypical antipsychotics. Recently, a new radioiodinated ligand with high affinity and selectivity for serotonin 5-HT{sub 2A} receptors, {sup 123}iodinated 4-amino-N-1-[3-(4-fluorophenoxy)propyl-4-methyl-4-piperidinyl] 5-iodo-2-methoxybenzamide ({sup 123}I-5-I-R91150), has been developed and has been shown to be suitable for single-photon emission tomography (SPET) imaging. In this study the influence of age and gender on the ligand binding was investigated in normal volunteers. One hundred and fifty MBq of {sup 123}I-5-I-R91150 was administered to 26 normal volunteers (13 females and 13 males) with an age range of 23-60 years. SPET imaging was performed with a triple-headed gamma camera. For semi-quantitative analysis, ratios of ligand binding in different regions of interest to the binding in the cerebellum were calculated. Mean ratios of 1.7 were obtained. No gender difference was demonstrated. 5-HT{sub 2A} binding was shown to decline with age. Over an age range of 40 years a reduction in ligand binding of 42%{+-}7% was found. These results are in agreement with in vitro and positron emission tomography findings of a decline in 5-HT{sub 2A} receptor binding with age. The findings confirm the suitability of {sup 123}I-5-I-R91150 for SPET imaging of 5-HT{sub 2A} receptors, and highlight the necessity for age-matched controls in clinical studies. (orig.) With 3 figs., 3 tabs., 33 refs.

  11. Imaging of Integrin αvβ3 Expression in Lung Cancers and Brain Tumors Using Single-Photon Emission Computed Tomography with a Novel Radiotracer 99mTc-IDA-D-[c(RGDfK)]2.

    Science.gov (United States)

    Song, Yoo Sung; Park, Hyun Soo; Lee, Byung Chul; Jung, Jae Ho; Lee, Ho-Young; Kim, Sang Eun

    2017-10-01

    Integrin αvβ3 is a molecular marker for the estimation of tumor angiogenesis and is an imaging target for radiolabeled Arg-Gly-Asp (RGD) peptides. In this study, the authors investigated the clinical efficacy and safety of a novel radiolabeled RGD peptide, 99mTc-IDA-D-[c(RGDfK)]2, for the imaging of integrin αvβ3 expression, as a measure of tumor angiogenesis in lung cancers and brain tumors. Five patients with lung cancers and seven with brain tumors underwent 99mTc-IDA-D-[c(RGDfK)]2 single-photon emission computed tomography (SPECT) imaging. Tumors were also assessed using 18F-fluorodeoxyglucose positron emission tomography/computed tomography. Uptake of the radiotracer was expressed as the tumor-to-normal uptake ratio (TNR). All the lung cancers and brain tumors were well visualized on 99mTc-IDA-D-[c(RGDfK)]2 SPECT. TNR for 99mTc-IDA-D-[c(RGDfK)]2 was significantly higher than that for 18F-FDG in brain tumors (6.4 ± 4.1 vs. 0.9 ± 0.4). Proliferation index of brain tumors showed a significant positive correlation with TNR for 99mTc-IDA-D-[c(RGDfK)]2 and 18F-FDG. No laboratory and clinical adverse events were reported after 99mTc-IDA-D-[c(RGDfK)]2 injection. Their results suggest that 99mTc-IDA-D-[c(RGDfK)]2 is an efficacious and safe radiotracer for imaging integrin αvβ3 expression with potential application to monitoring the clinical efficacy of antiangiogenic agents in malignant tumors. In addition, this is the first clinical application of radiolabeled RGD peptides for SPECT imaging of brain tumors.

  12. Frequency Conversion of Single Photons: Physics, Devices, and Applications

    Science.gov (United States)

    2012-07-01

    89 6.7 Rabi oscillations in photon counts for downconverted quantum dot single photons...dot, and show that the photon statistics of the quantum dot emission are preserved. Additionally, through the observation of Rabi oscillations in the...InAs is grown by molecular beam epitaxy (MBE, [119]) on a GaAs substrate, due to the lattice mismatch between InAs and GaAs, after the growth of a

  13. Integrated optomechanical single-photon frequency shifter

    Science.gov (United States)

    Fan, Linran; Zou, Chang-Ling; Poot, Menno; Cheng, Risheng; Guo, Xiang; Han, Xu; Tang, Hong X.

    2016-12-01

    The ability to manipulate single photons is of critical importance for fundamental quantum optics studies and practical implementations of quantum communications. While extraordinary progresses have been made in controlling spatial, temporal, spin and orbit angular momentum degrees of freedom, frequency-domain control of single photons so far relies on nonlinear optical effects, which have faced obstacles such as noise photons, narrow bandwidth and demanding optical filtering. Here, we demonstrate the first integrated optomechanical single-photon frequency shifter with near-unity efficiency. A frequency shift up to 150 GHz at telecom wavelength is realized without measurable added noise and the preservation of quantum coherence is verified through quantum interference between twin photons of different colours. This single-photon frequency shifter will be invaluable for increasing the channel capacity of quantum communications and compensating frequency mismatch between quantum systems, paving the road towards a hybrid quantum network.

  14. Single Photon Emission Computed Tomography (SPECT)

    Science.gov (United States)

    ... comfortable shoes if you will have an exercise stress test. What happens during cardiac SPECT? A doctor and nuclear medicine technologist usually perform the scan in a hospital or clinic using special equipment. The technician will ...

  15. Multimodal Imaging of Integrin Receptor-Positive Tumors by Bioluminescence, Fluorescence, Gamma Scintigraphy, and Single-Photon Emission Computed Tomography Using a Cyclic RGD Peptide Labeled with a Near-Infrared Fluorescent Dye and a Radionuclide

    Directory of Open Access Journals (Sweden)

    W. Barry Edwards

    2009-03-01

    Full Text Available Integrins, particularly the αvβ3 heterodimers, play important roles in tumor-induced angiogenesis and invasiveness. To image the expression pattern of the αvβ3 integrin in tumors through a multimodality imaging paradigm, we prepared a cyclic RGDyK peptide analogue (LS308 bearing a tetraazamacrocycle 1,4,7,10-tetraazacyclododecane-N, N′, N″, N‴-tetraacetic acid (DOTA and a lipophilic near-infrared (NIR fluorescent dye cypate. The αvβ3 integrin binding affinity and the internalization properties of LS308 mediated by the αvβ3 integrin in 4t1luc cells were investigated by receptor binding assay and fluorescence microscopy, respectively. The in vivo distribution of 111In-labeled LS308 in a 4t1luc tumor-bearing mouse model was studied by fluorescence, bioluminescence, planar gamma, and single-photon emission computed tomography (SPECT. The results show that LS308 has high affinity for αvβ3 integrin and internalized preferentially via the αvβ3 integrin-mediated endocytosis in 4t1luc cells. We also found that LS308 selectively accumulated in αvβ3-positve tumors in a receptor-specific manner and was visualized by the four imaging methods. Whereas the endogenous bioluminescence imaging identified the ensemble of the tumor tissue, the fluorescence and SPECT methods with the exogenous contrast agent LS308 reported the local expression of αvβ3 integrin. Thus, the multimodal imaging approach could provide important complementary diagnostic information for monitoring the efficacy of new antiangiogenic drugs.

  16. Diagnostic performance of coronary CT angiography, stress dual-energy CT perfusion, and stress perfusion single-photon emission computed tomography for coronary artery disease: Comparison with combined invasive coronary angiography and stress perfusion cardiac MRI

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Hyun Woo; Ko, Sung Min; Hwang, Hweung Kon; So, Young; Yi, Jeong Geun [Konkuk University Medical Center, Research Institute of Biomedical Science, Konkuk University School of Medicine, Seoul (Korea, Republic of); Lee, Eun Jeong [Dept. of Nuclear Medicine, Seoul Medical Center, Seoul (Korea, Republic of)

    2017-06-15

    To investigate the diagnostic performance of coronary computed tomography angiography (CCTA), stress dual-energy computed tomography perfusion (DE-CTP), stress perfusion single-photon emission computed tomography (SPECT), and the combinations of CCTA with myocardial perfusion imaging (CCTA + DE-CTP and CCTA + SPECT) for identifying coronary artery stenosis that causes myocardial hypoperfusion. Combined invasive coronary angiography (ICA) and stress perfusion cardiac magnetic resonance (SP-CMR) imaging are used as the reference standard. We retrospectively reviewed the records of 25 patients with suspected coronary artery disease, who underwent CCTA, DE-CTP, SPECT, SP-CMR, and ICA. The reference standard was defined as ≥ 50% stenosis by ICA, with a corresponding myocardial hypoperfusion on SP-CMR. For per-vascular territory analysis, the sensitivities of CCTA, DE-CTP, SPECT, CCTA + DE-CTP, and CCTA + SPECT were 96, 96, 68, 93, and 68%, respectively, and specificities were 72, 75, 89, 85, and 94%, respectively. The areas under the receiver operating characteristic curve (AUCs) were 0.84 ± 0.05, 0.85 ± 0.05, 0.79 ± 0.06, 0.89 ± 0.04, and 0.81 ± 0.06, respectively. For per-patient analysis, the sensitivities of CCTA, DE-CTP, SPECT, CCTA + DE-CTP, and CCTA + SPECT were 100, 100, 89, 100, and 83%, respectively; the specificities were 14, 43, 57, 43, and 57%, respectively; and the AUCs were 0.57 ± 0.13, 0.71 ± 0.11, 0.73 ± 0.11, 0.71 ± 0.11, and 0.70 ± 0.11, respectively. The combination of CCTA and DE-CTP enhances specificity without a loss of sensitivity for detecting hemodynamically significant coronary artery stenosis, as defined by combined ICA and SP-CMR.

  17. Prognostic value of myocardial perfusion single photon emission computed tomography for major adverse cardiac cerebrovascular and renal events in patients with chronic kidney disease: results from first year of follow-up of the Gunma-CKD SPECT multicenter study

    Energy Technology Data Exchange (ETDEWEB)

    Kasama, Shu [Gunma University Graduate School of Medicine, Department of Medicine and Biological Science (Cardiovascular Medicine), Maebashi, Gunma (Japan); Cardiovascular Hospital of Central Japan (Kitakanto Cardiovascular Hospital), Department of Cardiovascular Medicine, Gunma (Japan); Toyama, Takuji [Department of Cardiovascular Medicine, Gunma Prefectural Cardiovascular Center, Maebashi (Japan); Sato, Makito [Gunma University Graduate School of Medicine, Department of Medicine and Biological Science (Cardiovascular Medicine), Maebashi, Gunma (Japan); Tatebayashi Kosei Hospital, Department of Internal Medicine, Gunma (Japan); Sano, Hirokazu [Gunma University Graduate School of Medicine, Department of Medicine and Biological Science (Cardiovascular Medicine), Maebashi, Gunma (Japan); Isesaki Municipal Hospital, Department of Cardiovascular Medicine, Isesaki (Japan); Ueda, Tetsuya [Fujioka General Hospital, Division of Cardiology, Fujioka (Japan); Sasaki, Toyoshi [Takasaki General Medical Center, Division of Cardiology, Takasaki (Japan); Nakahara, Takehiro; Kurabayashi, Masahiko [Gunma University Graduate School of Medicine, Department of Medicine and Biological Science (Cardiovascular Medicine), Maebashi, Gunma (Japan); Higuchi, Tetsuya; Tsushima, Yoshito [Gunma University Graduate School of Medicine, Department of Diagnostic Radiology and Nuclear Medicine, Maebashi (Japan)

    2016-02-15

    Patients with chronic kidney disease (CKD) have an increased risk of adverse cardio-cerebrovascular events. We examined whether stress myocardial perfusion single photon emission computed tomography (SPECT) provides reliable prognostic markers for these patients. In this multicenter, prospective cohort trial from the Gunma-CKD SPECT study protocol, patients with CKD [estimated glomerular filtration rate (eGFR) < 60 min/ml per 1.73 m{sup 2}] undergoing stress {sup 99m}Tc-tetrofosmin SPECT for suspected or possible ischemic heart disease were initially followed for 1 year, with the following study endpoints: primary, the occurrence of cardiac deaths (CDs), and secondary, major adverse cardiac, cerebrovascular, and renal events (MACCREs). The summed stress score (SSS), summed rest score, and summed difference score (SDS) were estimated with the standard 17-segment, 5-point scoring model. Left ventricular end-diastolic volume, end-systolic volume (ESV), and ejection fraction were measured using electrocardiogram-gated SPECT. During the first year of follow-up, 69 of 299 patients experienced MACCREs (CD, n = 7; non-fatal myocardial infarction, n = 3; hospitalization for heart failure, n = 13; cerebrovascular accident, n = 1; need for revascularization, n = 38; and renal failure, i.e., hemodialysis initiation, n = 7). ESV and SSS were associated with CDs (p < 0.05), and eGFR and SDS were associated with MACCREs (p < 0.05), in multivariate logistic analysis. Patients with high ESV and high SSS had a significantly higher CD rate during the first year than the other CKD patient subgroups (p < 0.05). Patients with low eGFR and high SDS had a significantly higher MACCRE rate than the other subgroups (p < 0.05). Myocardial perfusion SPECT can provide reliable prognostic markers for patients with CKD. (orig.)

  18. Correspondence between large-scale ictal and interictal epileptic networks revealed by single photon emission computed tomography (SPECT) and electroencephalography (EEG)-functional magnetic resonance imaging (fMRI).

    Science.gov (United States)

    Tousseyn, Simon; Dupont, Patrick; Goffin, Karolien; Sunaert, Stefan; Van Paesschen, Wim

    2015-03-01

    Epilepsy is increasingly recognized as a network disorder, but the spatial relationship between ictal and interictal networks is still largely unexplored. In this work, we compared hemodynamic changes related to seizures and interictal spikes on a whole brain scale. Twenty-eight patients with refractory focal epilepsy (14 temporal and 14 extratemporal lobe) underwent both subtraction ictal single photon emission computed tomography (SPECT) coregistered to magnetic resonance imaging (MRI) (SISCOM) and spike-related electroencephalography (EEG-functional MRI (fMRI). SISCOM visualized relative perfusion changes during seizures, whereas EEG-fMRI mapped blood oxygen level-dependent (BOLD) changes related to spikes. Similarity between statistical maps of both modalities was analyzed per patient using the following two measures: (1) correlation between unthresholded statistical maps (Pearson's correlation coefficient) and (2) overlap between thresholded images (Dice coefficient). Overlap was evaluated at a regional level, for hyperperfusions and activations and for hypoperfusions and deactivations separately, using different thresholds. Nonparametric permutation tests were applied to assess statistical significance (p ≤ 0.05). We found significant and positive correlations between hemodynamic changes related to seizures and spikes in 27 (96%) of 28 cases (median correlation coefficient 0.29 [range -0.12 to 0.62]). In 20 (71%) of 28 cases, spatial overlap between hyperperfusion on SISCOM and activation on EEG-fMRI was significantly larger than expected by chance. Congruent changes were not restricted to the territory of the presumed epileptogenic zone, but could be seen at distant sites (e.g., cerebellum and basal ganglia). Overlap between ictal hypoperfusion and interictal deactivation was statistically significant in 22 (79%) of 28 patients. Despite the high rate of congruence, discrepancies were observed for both modalities. We conclude that hemodynamic changes

  19. Comparison of 99mTc-sestamibi-18F-fluorodeoxyglucose dual isotope simultaneous acquisition and rest-stress 99mTc-sestamibi single photon emission computed tomography for the assessment of myocardial viability.

    Science.gov (United States)

    De Boer, J; Slart, R H J A; Blanksma, P K; Willemsen, A T M; Jager, P L; Paans, A M J; Vaalburg, W; Piers, D A

    2003-03-01

    Dual isotope simultaneous acquisition single photon emission computed tomography (DISA SPECT) offers the advantage of obtaining information on myocardial perfusion using Tc-sestamibi ( Tc-MIBI) and metabolism using F-fluorodeoxyglucose ( F-FDG) in a single study. The prerequisite is that the Tc-MIBI images are not degraded by scattered 511 keV photons or poor count statistics due to the lower efficiency of the extra high energy (EHE) collimator. Therefore, we compared the registered Tc-MIBI uptake and image quality of DISA and single isotope acquisition. Furthermore, we investigated whether DISA yields additional information for the assessment of myocardial viability in comparison with rest-stress Tc-MIBI. Nineteen patients with known coronary artery disease and irreversible perfusion defects on previous rest-stress MIBI test studies were investigated. After oral glucose loading and simultaneous injection of 600 MBq of Tc-MIBI and 185 MBq of F-FDG at rest, DISA was performed using energy windows of 140 (+/-15%), 170 (+/-20%) and 511 keV (+/-15%). Planar 140 keV images were corrected for scatter by subtraction using the 170 keV window. The single and dual isotope Tc-MIBI images were both displayed in a polar map with 128 segments normalized to maximum counts. F-FDG and Tc-MIBI images were visually scored for a perfusion-metabolism mismatch pattern using nine regions per heart. There was an excellent correlation (r =0.93, PDISA does not affect the quality of the Tc-MIBI images. Furthermore, F-FDG- Tc-MIBI DISA may show viability in a small but significant (7.6%, P<0.0034) number of regions with irreversible perfusion defects on rest-stress Tc-MIBI.

  20. Influence of intravenously administered lidocaine on cerebral blood flow in a baboon model standardized under controlled general anaesthesia using single-photon emission tomography and technetium-99m hexamethylpropylene amine oxime

    Energy Technology Data Exchange (ETDEWEB)

    Dormehl, I.C. (AEC Inst. for Life Sciences, Pretoria Univ. (South Africa)); Lipp, M.D.W. (Klinik fuer Anaesthesiologie, Johannes Gutenberg Univ., Mainz (Germany)); Hugo, N. (AEC Inst. for Life Sciences, Pretoria Univ. (South Africa)); Daublaender, M. (Stadtkrankenhaus Landau, Abt. fuer Mund-, Kiefer- und Gesichtschirurgie (Germany)); Picard, J.A. (H.A. Grove Research Centre, Pretoria (South Africa))

    1993-11-01

    The baboon under general anaesthesia as a model to assess druginduced cerebral blood flow changes ([Delta] CBF) using single-photon emission tomography (SPET) offers great in vivo possibilities but has to comply with demands on control of anaestesia-related influencing factors, such as P[sub a]CO[sub 2] changes. The model sought in this study and described here allows control of P[sub a]CO[sub 2], in the baboon under thiopentone anaesthesia by ventilation, and was evaluated for the functioal dependence of [Delta] CBF vs [Delta] P[sub a]CO[sub 2], using SPET technetium-99m hexamethylpropylene amine oxime (HMPAO) and the split-dose method together with controlled ventilation. During the experiment the model was validated for normal reactivity to P[sub a]CO[sub 2] changes, and subsequently applied to investigate the mechanisms (still uncertain) of CBF increase known to follow administration of the local anaesthetic lidocaine. Six baboons received 6 mg/kg lidocaine intravenously. CBF was measured between two consecutive SPET acquisitions (split-dose method) respectively relating to HMPAO distributions in the brain before and after the injection of lidocaine. Meanwhile the animals were maintained at constant respiratory rate and volume. The results indicate that the correlation between D CBF and the ensuing fall in P[sub a]CO[sub 2] deviated from the baseline pattern from the model and confirmed a cerebrovascular contribution to the lidocaine-induced CBF increase. This agreed well with mean and systolic blood pressure changes and heart rate. (orig.)

  1. Bone and Gallium Single-Photon Emission Computed Tomography-Computed Tomography is Equivalent to Magnetic Resonance Imaging in the Diagnosis of Infectious Spondylodiscitis: A Retrospective Study.

    Science.gov (United States)

    Tamm, Alexander S; Abele, Jonathan T

    2017-02-01

    Spondylodiscitis has historically been a difficult clinical diagnosis. Two imaging techniques that address this problem are magnetic resonance imaging (MRI) and combined bone (99mTc-methylene diphosphonate) and gallium-67 single-photon emission computed tomography-computed tomography (SPECT-CT). Their accuracies have not been adequately compared. The purpose of this study is to compare the sensitivities and specificities of bone and gallium SPECT-CT and MRI in infectious spondylodiscitis. This retrospective study assessed all patients who underwent a bone or gallium SPECT-CT of the spine to assess for infectious spondylodiscitis from January 1, 2010, to May 2, 2012, at a single tertiary care centre. Thirty-four patients (23 men; average 62 ± 14 years of age) were included. The results of the bone or gallium SPECT-CT were compared against MRI for all patients in the cohort who underwent an MRI within 12 weeks of the SPECT-CT. A diagnosis of spondylodiscitis in the discharge summary was considered the reference standard, and was based on a combination of clinical scenario, response to therapy, imaging, or microbiology. Spondylodiscitis was diagnosed in 18 patients and excluded in 16. Bone or gallium SPECT-CT and MRI had similar (P > .05; κ = 0.74) sensitivities (0.94 vs 0.94), specificities (1.00 vs 1.00), positive predictive values (1.00 vs 1.00), negative predictive values (0.94 vs 0.80), and accuracies (0.97 vs 0.95) when compared to the reference standard. Although MRI remains the initial modality of choice in diagnosing spondylodiscitis, bone and gallium SPECT-CT appears diagnostically equivalent and should be considered a viable supplementary or alternative imaging modality particularly if there is contraindication or inaccessibility to MRI. Copyright © 2016 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  2. Regional cerebral blood flow single-photon emission tomography with {sup 99m}Tc-HMPAO and the acetazolamide test in the evaluation of vascular and Alzheimer`s dementia

    Energy Technology Data Exchange (ETDEWEB)

    Pavics, L.; Csernay, L. [Department of Nuclear Medicine, Albert Szent-Gyoergyi Medical University, Szeged (Hungary); Gruenwald, F.; Reichmann, K.; Menzel, C.; Schomburg, A.G.; Overbeck, B.; Biersack, H.J. [Department of Nuclear Medicine, University of Bonn (Germany); Horn, R.; Kitschenberg, A.; Hartmann, A. [Department of Neurology, University of Bonn (Germany)

    1999-03-01

    The diagnostic potential of technetium-99m hexamethylpropylene amine oxime (HMPAO) following systemic administration of the cerebral vasodilator acetazolamide (acetazolamide test) was evaluated by regional cerebral blood flow (rCBF) single-photon emission tomography (SPET) in patients with Alzheimer`s disease (AD) or vascular dementia (VD). An initial, high-resolution SPET study was performed with {sup 99m}Tc-HMPAO, and after 2 days the patients were re-evaluated with {sup 99m}Tc-HMPAO following systemic administration of acetazolamide. Reconstructed SPET slices were evaluated visually and semiquantitatively by a semi-automatic rCBF map method. When {sup 99m}Tc-HMPAO alone was used, bilateral hypoperfusion was found in the temporal and/or parietal regions in 33% (6/18) of the VD patients and in 70% (23/33) of the AD patients. The corresponding data obtained by quantitative evaluation were 41% (7/17) and 71% (15/21), respectively. The vascular reserve capacity, as determined with the acetazolamide test, was preserved visually in 22% (4/18) and quantitatively in 29% (5/17) of the VD patients, but in 73% (24/33) and 76% (16/21) of the AD patients. The differences in the perfusion patterns between the VD and AD patients were statistically significant (P<0.01, Fischer`s exact test). Of the VD patients with hypoperfusion (bilateral temporal and/or parietal), 4/6 (67%, visual evaluation) and 4/7 (57%, quantitative evaluation) had a decreased vascular reserve capacity as determined with the acetazolamide test. In the AD group of patients the corresponding results were 3/23 (13%) and 4/15 (27%). It is concluded that the acetazolamide test is promising in rCBF SPET to differentiate VD from AD. (orig.) With 4 figs., 3 tabs., 29 refs.

  3. p-NO2-Bn-H4neunpa and H4neunpa-Trastuzumab: Bifunctional Chelator for Radiometalpharmaceuticals and (111)In Immuno-Single Photon Emission Computed Tomography Imaging.

    Science.gov (United States)

    Spreckelmeyer, Sarah; Ramogida, Caterina F; Rousseau, Julie; Arane, Karen; Bratanovic, Ivica; Colpo, Nadine; Jermilova, Una; Dias, Gemma M; Dude, Iulia; Jaraquemada-Peláez, Maria de Guadalupe; Bénard, François; Schaffer, Paul; Orvig, Chris

    2017-08-16

    Potentially nonadentate (N5O4) bifunctional chelator p-SCN-Bn-H4neunpa and its immunoconjugate H4neunpa-trastuzumab for (111)In radiolabeling are synthesized. The ability of p-SCN-Bn-H4neunpa and H4neunpa-trastuzumab to quantitatively radiolabel (111)InCl3 at an ambient temperature within 15 or 30 min, respectively, is presented. Thermodynamic stability determination with In(3+), Bi(3+), and La(3+) resulted in high conditional stability constant (pM) values. In vitro human serum stability assays have demonstrated both (111)In complexes to have high stability over 5 days. Mouse biodistribution of [(111)In][In(p-NO2-Bn-neunpa)](-), compared to that of [(111)In][In(p-NH2-Bn-CHX-A″-diethylenetriamine pentaacetic acid (DTPA))](2-), at 1, 4, and 24 h shows fast clearance of both complexes from the mice within 24 h. In a second mouse biodistribution study, the immunoconjugates (111)In-neunpa-trastuzumab and (111)In-CHX-A″-DTPA-trastuzumab demonstrate a similar distribution profile but with slightly lower tumor uptake of (111)In-neunpa-trastuzumab compared to that of (111)In-CHX-A″-DTPA-trastuzumab. These results were also confirmed by immuno-single photon emission computed tomography (immuno-SPECT) imaging in vivo. These initial investigations reveal the acyclic bifunctional chelator p-SCN-Bn-H4neunpa to be a promising chelator for (111)In (and other radiometals) with high in vitro stability and also show H4neunpa-trastuzumab to be an excellent (111)In chelator with promising biodistribution in mice.

  4. Distribution of Functional Liver Volume in Hepatocellular Carcinoma Patients with Portal Vein Tumor Thrombus in the 1st Branch and Main Trunk Using Single Photon Emission Computed Tomography—Application to Radiation Therapy

    Directory of Open Access Journals (Sweden)

    Akira Ikoma

    2011-10-01

    Full Text Available Purpose: To analyze the distribution of functional liver volume (FLV in the margin volume (MV surrounding hepatocellular carcinoma (HCC with portal vein tumor thrombus (PVTT before radiation therapy (RT and to verify the safety of single photon emission computed tomography-based three-dimensional conformal radiotherapy (SPECT-B3DCRT by exploring the relation of FLV in MV to radiation-induced liver disease (RILD. Methods and Materials: Clinical target volume (CTV included main tumor and PVTT, and planning target volume (PTV included CTV with a 10 mm margin. MV was defined as PTV–CTV. FLV ratio in MV was calculated as FLV in MV/MV × 100 (%. The two high-dose beams were planned to irradiate FLV as little as possible. Fifty-seven cases of HCC (26/57, 46%; Child–Pugh grade B with PVTT underwent SPECT-B3DCRT which targeted the CTV to a total dose of 45 Gy/18 fractions. The destructive ratio was defined as radiation induced dysfunctional volume/FLV × 100 (%. Results: We observed a significant negative correlation between FLV ratio in MV and CTV (p < 0.001. Three cases with CTVs of 287, 587 and 1184 cm3 experienced transient RILD. The FLV ratio in MV was highest in patients with RILD: nine patients with CTV of 200–300 cm3, three with CTV of 500–600 cm3, and two with CTV of 1100–1200 cm3. The destructive ratio yielded a mean value of 24.2 ± 1.5%. Conclusions: Radiation planning that takes into account the distribution of FLV appears to result in the least possible RILD.

  5. Quantitative Analysis of Iodine Image of Dual-energy Computed Tomography at Rest: Comparison With 99mTc-Tetrofosmin Stress-rest Single-photon Emission Computed Tomography Myocardial Perfusion Imaging as the Reference Standard.

    Science.gov (United States)

    Nakahara, Takehiro; Toyama, Takuji; Jinzaki, Masahiro; Seki, Ryotaro; Saito, Yuichiro; Higuchi, Tetsuya; Yamada, Minoru; Arai, Masashi; Tsushima, Yoshito; Kuribayashi, Sachio; Kurabayashi, Masahiko

    2017-06-15

    Dual-energy computed tomography (DECT) can be used for visual determination of iodine distribution in the myocardium (iodine image); however, the accuracy and reproducibility of the process remains debatable. Because of the low contrast-to-noise ratio of CT, we hypothesized that quantitative measurement may be more accurate for detecting myocardial ischemia. In this study, we evaluated our quantitative method by comparing it with visual analysis using Tc-tetrofosmin (TF) stress-rest single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) as the reference standard. Forty-three patients who had a significant stenosis on cardiac rest DECT and had received Tc-TF stress-rest SPECT MPI within 1 month were retrospectively analyzed. The regions of interest were set on iodine images in accordance with the American Heart Association (AHA) 17-segment model (a total of 731 segments). The regions of interest values were divided by the amount of iodine (mg) per unit weight (kg) and defined as perfusion value (perfusion value analysis). All segments were also visually analyzed and receiver operating characteristic curve analysis performed to identify the superior analysis. The receiver operating characteristic curve analysis showed that perfusion value analysis is significantly superior to visual analysis [the area under the curve: 0.921 (95% confidence interval, 0.860-0.981) versus 0.685 (95% confidence interval, 0.580-0.791), respectively, P<0.05], with 93.8% sensitivity, 99.1% specificity, 98.9% accuracy, 83.3% positive predictive value, and 99.7% negative predictive value (P<0.01). Quantitative analysis of the iodine image of rest DECT, called perfusion value analysis, is more accurate than visual analysis when compared with Tc-TF SPECT MPI as the reference standard.

  6. Transplantation and tracking of human-induced pluripotent stem cells in a pig model of myocardial infarction: assessment of cell survival, engraftment, and distribution by hybrid single photon emission computed tomography/computed tomography of sodium iodide symporter transgene expression.

    Science.gov (United States)

    Templin, Christian; Zweigerdt, Robert; Schwanke, Kristin; Olmer, Ruth; Ghadri, Jelena-Rima; Emmert, Maximilian Y; Müller, Ennio; Küest, Silke M; Cohrs, Susan; Schibli, Roger; Kronen, Peter; Hilbe, Monika; Reinisch, Andreas; Strunk, Dirk; Haverich, Axel; Hoerstrup, Simon; Lüscher, Thomas F; Kaufmann, Philipp A; Landmesser, Ulf; Martin, Ulrich

    2012-07-24

    Evaluation of novel cellular therapies in large-animal models and patients is currently hampered by the lack of imaging approaches that allow for long-term monitoring of viable transplanted cells. In this study, sodium iodide symporter (NIS) transgene imaging was evaluated as an approach to follow in vivo survival, engraftment, and distribution of human-induced pluripotent stem cell (hiPSC) derivatives in a pig model of myocardial infarction. Transgenic hiPSC lines stably expressing a fluorescent reporter and NIS (NIS(pos)-hiPSCs) were established. Iodide uptake, efflux, and viability of NIS(pos)-hiPSCs were assessed in vitro. Ten (±2) days after induction of myocardial infarction by transient occlusion of the left anterior descending artery, catheter-based intramyocardial injection of NIS(pos)-hiPSCs guided by 3-dimensional NOGA mapping was performed. Dual-isotope single photon emission computed tomographic/computed tomographic imaging was applied with the use of (123)I to follow donor cell survival and distribution and with the use of (99m)TC-tetrofosmin for perfusion imaging. In vitro, iodide uptake in NIS(pos)-hiPSCs was increased 100-fold above that of nontransgenic controls. In vivo, viable NIS(pos)-hiPSCs could be visualized for up to 15 weeks. Immunohistochemistry demonstrated that hiPSC-derived endothelial cells contributed to vascularization. Up to 12 to 15 weeks after transplantation, no teratomas were detected. This study describes for the first time the feasibility of repeated long-term in vivo imaging of viability and tissue distribution of cellular grafts in large animals. Moreover, this is the first report demonstrating vascular differentiation and long-term engraftment of hiPSCs in a large-animal model of myocardial infarction. NIS(pos)-hiPSCs represent a valuable tool to monitor and improve current cellular treatment strategies in clinically relevant animal models.

  7. Dynamically unpolarized single-photon source in diamond with intrinsic randomness

    Science.gov (United States)

    Abe, Naofumi; Mitsumori, Yasuyoshi; Sadgrove, Mark; Edamatsu, Keiichi

    2017-04-01

    Polarization is one of the fundamental properties of light, providing numerous applications in science and technology. While ‘dynamically unpolarized’ single-photon sources are demanded for various quantum applications, such sources have never been explored. Here we demonstrate dynamically unpolarized single-photon emission from a single [111]-oriented nitrogen- vacancy centre in diamond, in which the single-photon stream is unpolarized, exhibiting intrinsic randomness with vanishing polarization correlation between time adjacent photons. These properties not only allow true random number generation, but may also enable fundamental tests in quantum physics.

  8. Phase estimation with squeezed single photons

    Directory of Open Access Journals (Sweden)

    Olivares Stefano

    2016-01-01

    Full Text Available We address the performance of an interferometric setup in which a squeezed single photon interferes at a beam splitter with a coherent state. Our analysis in based on both the quantum Fisher information and the sensitivity when a Mach-Zehnder setup is considered and the difference photocurrent is detected at the output. We compare our results with those obtained feeding the interferometer with a squeezed vacuum (with the same squeezing parameter of the squeezed single photon and a coherent state in order to have the same total number of photons circulating in the interferometer. We find that for fixed squeezing parameter and total number of photons there is a threshold of the coherent amplitude interfering with the squeezed single photon above which the squeezed single photons outperform the performance of squeezed vacuum (showing the highest quantum Fisher information. When the difference photocurrent measurement is considered, we can always find a threshold of the squeezing parameter (given the total number of photons and the coherent amplitude above which squeezed single photons can be exploited to reach a better sensitivity with respect to the use of squeezed vacuum states also in the presence of non unit quantum efficiency.

  9. Efficient generation of indistinguishable single photons on-demand at telecom wavelengths

    Science.gov (United States)

    Kim, Jehyung; Cai, Tao; Richardson, Christopher; Leavitt, Richard; Waks, Edo

    Highly efficient single photon sources are important building blocks for optical quantum information processing. For practical use and long-distance quantum communication, single photons should have fiber-compatible telecom wavelengths. In addition, most quantum communication applications require high degree of indistinguishability of single photons, such that they exhibit interference on a beam splitter. However, deterministic generation of indistinguishable single photons with high brightness remains a challenging problem in particular at telecom wavelengths. We demonstrate a telecom wavelength source of indistinguishable single photons using an InAs/InP quantum dot in a nanophotonic cavity. To obtain the efficient single quantum dot emission, we employ the higher order mode in L3 photonic crystal cavity that shows a nearly Gaussian transverse mode profile and results in out-coupling efficiency exceeding 46 % and unusual bright single quantum dot emission exceeding 1.5 million counts per second at a detector. We also observe Purcell enhanced spontaneous emission rate as large as 4 and high linear polarization ratio of 0.96 for the coupled dots. Using this source, we generate high purity single photons at 1.3 μm wavelength and demonstrate the indistinguishable nature of the emission using a two-photon interference measurement.

  10. The influence of phonon bath on the control of single photon

    Science.gov (United States)

    Zhang, Wei; Lu, Hai-Tao

    2015-06-01

    The influence of vacuum fluctuation and phonon bath on the probability of single photon emission are both considered in the two-level system model theoretically; by using the master equations and generating function method we get the analytical expression of the second-order fluorescence correlation function, probability of single photon emission, and Mandel’s Q parameter. The results manifest that the coupling between the phonon bath and single photon source destroys the superposition state induced by the square laser pulse, the Rabi oscillation damped rapidly with the increasing of temperature. Theoretically, when the structure parameter of arsenide quantum dots α scaled to 0.1 times of the sample, the critical coherence-temperature will rise up to hundreds of Kelvin, which means a step forward to the realization of coherent control of single photon source at room temperature. Project supported by the Fundamental Research Funds for the Central Universities of Central South University, China (Grant No. 2014zzts145).

  11. Occupancy of dopamine D{sub 2} receptors in the mouse brain measured using ultra-high-resolution single-photon emission tomography and [{sup 123}I]IBF

    Energy Technology Data Exchange (ETDEWEB)

    Acton, Paul D.; Hou, Catherine; Kung, Mei-Ping; Ploessl, Karl; Keeney, Cindy L. [Department of Radiology, University of Pennsylvania, 3700 Market Street, Room 305, Philadelphia, PA 19104 (United States); Kung, Hank F. [Department of Radiology, University of Pennsylvania, 3700 Market Street, Room 305, Philadelphia, PA 19104 (United States); Department of Pharmacology, University of Pennsylvania, Philadelphia (United States)

    2002-11-01

    Functional imaging of small animals, such as mice and rats, using ultra-high-resolution positron emission tomography (PET) and single-photon emission tomography (SPET) should be a valuable tool in studies of drug occupancy of cerebral binding sites. In this study we aimed to demonstrate the feasibility of using ultra-high-resolution SPET to measure the occupancy of dopamine D{sub 2} receptors by a competing drug, using the dopamine D{sub 2} receptor-specific radioligand iodine-123 5-iodo-7-N-[(1-ethyl-2-pyrrolidinyl) methyl] carboxamido-2,3-dihydrobenzofuran ([{sup 123}I]IBF). Fourteen normal male mice (CD-1) were jugular vein-cannulated and a bolus infusion protocol was used to deliver 360 MBq [{sup 123}I]IBF into the mouse (bolus-to-infusion ratio 1.8:1). The mice were scanned using an ultra-high-resolution triple-headed SPET system equipped with pinhole collimators. After sustained equilibrium had been achieved, varying doses of raclopride, a potent dopamine D{sub 2} receptor antagonist, were injected through the tail vein and the tracer was allowed to regain equilibrium. A simple equilibrium ratio of striatum to cerebellum provided a measure of D{sub 2} receptor binding both before and after injection of raclopride. Following raclopride administration, the system returned to equilibrium with lower specific binding in the striatum, while the counts in the cerebellum were unaffected. Receptor occupancy was 5.2%{+-}2.9% (control), 52.1%{+-}11.1% (0.3 mg/kg), 79.3%{+-}4.8% (1.0 mg/kg), and 94.7%{+-}2.2% (3.0 mg/kg), which gave an ED{sub 50}=0.26{+-}0.03 mg/kg using a single receptor site saturation model. This study has demonstrated clearly that ultra-high-resolution SPET of small animals is capable of measuring displacement and occupancy of dopamine D{sub 2} receptors by competing ligands. (orig.)

  12. Quantum identity authentication with single photon

    Science.gov (United States)

    Hong, Chang ho; Heo, Jino; Jang, Jin Gak; Kwon, Daesung

    2017-10-01

    Quantum identity authentication with single photons is proposed in the paper. It can verify a user's identity without exposing to an authentication key information. The protocol guarantees high efficiency in that it can verify two bits of authentication information using just a single photon. The security of our authentication scheme is analyzed and confirmed in the case of a general attack. Moreover, the proposed protocol is practicable with current technology. Our quantum identity authentication protocol does not require quantum memory registration and any entangled photon sources.

  13. Single-photon manipulation in Nanophotonic Circuits

    DEFF Research Database (Denmark)

    Hansen, Sofie Lindskov

    Quantum dots in photonic nanostructures has long been known to be a very powerful and versatile solid-state platform for conducting quantum optics experiments. The present PhD thesis describes experimental demonstrations of single-photon generation and subsequent manipulation all realized...... be realized on a chip with embedded quantum dots. This allows for on-chip generation and manipulation of single photons. The router consists of an on-chip interferometer where the phase difference between the arms of the interferometer is controlled electrically. The response time of the device...

  14. Global Algorithm Applied on Single Photon Detection

    Science.gov (United States)

    LIU, Hua; DING, Quanxin; Wang, Helong; Chen, Hongliang; GUO, Chunjie; ZHOU, Liwei

    2017-06-01

    There are three major contributions. Firstly, applied study on the theory and experiment of single photon detection, including the project and experiment of quantum key distribution. Secondly, based on methods of the selection of detector, main photo electronic system configuration, design and creation, along with the relationship between these to system characteristics have been studied. Thirdly, based on the considerations on the research of image sensor systems on single photon detection, and the total system characteristics are evaluated and discussed in quantity. The results of simulation experiments and theory analyzing demonstrate that proposed method could advance the system validity effectively, and theory analysis and experiment shows the method is reasonable and efficient.

  15. Dobutamine stress echocardiography and technetium-99m-tetrofosmin/fluorine 18-fluorodeoxyglucose single-photon emission computed tomography and influence of resting ejection fraction to assess myocardial viability in patients with severe left ventricular dysfunction and healed myocardial infarction.

    Science.gov (United States)

    Rambaldi, R; Poldermans, D; Bax, J J; Boersma, E; Valkema, R; Elhendy, A; Vletter, W B; Fioretti, P M; Roelandt, J R; Krenning, E P

    1999-07-15

    The purpose of this study was to compare 2 different techniques--dobutamine-atropine stress echocardiography (DSE) and dual-isotope simultaneous acquisition (technetium-99-m-tetrofosmin/fluorine 18-fluorodeoxyglucose) single-photon emission computed tomography (DISA-SPECT)--for assessment of viable myocardium. One hundred ten patients (mean age 55 +/- 9 years) with left ventricular (LV) dysfunction (mean LV ejection fraction 27 +/- 13%) underwent both DISA-SPECT and DSE. A 16-segment scoring model was adopted for both techniques. Four types of wall motion during DSE were assessed: (1) biphasic, improvement at low dose (10 microg/kg/min) with worsening at high dose; (2) worsening, deterioration without initial improvement; (3) sustained, persistent or late improvement; and (4) no change. Viability criteria were biphasic, worsening, and sustained improvement with DSE. Viability criteria with DISA-SPECT were normal perfusion and metabolism (normal), concordantly mildly reduced perfusion and metabolism (subendocardial scar), or severely reduced perfusion and increased metabolism (mismatch). Myocardium was considered nonviable with DSE in case of unchanged wall motion, or moderate reduction or absence in both technetium-99m-tetrofosmin perfusion and fluorodeoxyglucose uptake with DISA-SPECT. Of 1,756 of 1,760 analyzable LV segments, 1,373 (78%) had severe wall motion abnormalities at baseline (severe hypokinesia, akinesia, or dyskinesia). Of these abnormal segments, 282 (21%) were considered viable during DSE (63 [5%] with biphasic response, 47 [3%] with ischemia, and 172 [13%]) with sustained improvement, whereas 1,091 (79%) were considered nonviable. With DISA-SPECT, 396 (29%) segments were considered viable (312 [23%] with matched perfusion/metabolism and 84 [6%] with mismatch), whereas 977 segments (71%) were considered nonviable. Both techniques showed agreement for viability in 201 segments and 896 were concordantly classified as nonviable. Disagreement was

  16. Semiquantification and classification of local pulmonary function by V/Q single photon emission computed tomography in patients with non-small cell lung cancer: potential indication for radiotherapy planning.

    Science.gov (United States)

    Yuan, Shuanghu Tiger; Frey, Kirk A; Gross, Milton D; Hayman, James A; Arenberg, Doug; Curtis, Jeffrey L; Cai, Xu-Wei; Ramnath, Nithya; Kalemkerian, Gregory P; Ten Haken, Randall K; Eisbruch, Avraham; Kong, Feng-Ming Spring

    2011-01-01

    Perfusion (Q) single photon emission computed tomography (SPECT) has been used to divert dose away from higher-functioning lung during radiation therapy (RT) planning. This study aimed to (1) study regional lung function through coregistered pulmonary ventilation/perfusion (V/Q)-SPECT-CT and (2) classify these defects for its potential value in radiation planning in patients with non-small cell lung cancer (NSCLC). Patients with stages I to III NSCLC requiring radiation-based therapy were eligible for this prospective study. V/Q-SPECT performed within 2 weeks before the start of radiation was interpreted by nuclear medicine physicians and then measured by a semiquantitative score. The potential mechanism of V and Q defects was analyzed; the potential impact of V/Q-SPECT over Q-SPECT alone was completed through classified applications (high-dose RT versus RT avoidance) during planning. Images of 51 consecutive patients were analyzed. The V and Q defects were matched, reverse mismatched (V defect > Q defect), and mismatched (Q defect > V defect) in 61, 31, and 8% of patients, respectively. Tumor was the leading cause of the defects of ipsilateral lung in 73% of patients. The defect scores of the ipsilateral lung were greater in patients with central primaries than those with peripheral primaries for both V-SPECT (2.3 ± 1.1 versus 1.5 ± 0.8, p = 0.017) and Q-SPECT (2.2 ± 0.8 versus 1.4 ± 0.6, p = 0.000). The patients with chronic obstructive pulmonary disease had greater defect scores in contralateral lung for both V-SPECT (1.5 ± 0.7 versus 1.0 ± 0.8, p = 0.006) and Q-SPECT (1.4 ± 0.6 versus 1.0 ± 0.4, p = 0.010). On assessing the potential value of SPECT on RT plan, 39% of patients could have their RT plan when applying V/Q-SPECT rather than Q-SPECT alone. V/Q-SPECT provides a more comprehensive functional assessment, may provide additional value over Q-SPECT alone in assessing local pulmonary function, and guide RT plan decisions in patients with NSCLC.

  17. Selvester QRS score and total perfusion deficit calculated by quantitative gated single-photon emission computed tomography in patients with prior anterior myocardial infarction in the coronary intervention era.

    Science.gov (United States)

    Kurisu, Satoshi; Shimonaga, Takashi; Ikenaga, Hiroki; Watanabe, Noriaki; Higaki, Tadanao; Ishibashi, Ken; Dohi, Yoshihiro; Fukuda, Yukihiro; Kihara, Yasuki

    2017-04-01

    Selvester QRS scoring system has an advantage of being inexpensive and easily accessible for estimating myocardial infarct (MI) size. We assessed the correlation and agreement between QRS score and total perfusion deficit (TPD) calculated by quantitative gated single-photon emission computed tomography (QGS) in patients with prior anterior MI undergoing coronary intervention. Sixty-six patients with prior anterior MI and 66 age- and sex-matched control subjects were enrolled. QRS score was obtained using a 50-criteria and 31-point system. QRS score was significantly higher in patients with prior anterior MI than control subjects (12.8 ± 8.9 vs 1.1 ± 2.7 %, p < 0.001). In overall patients (n = 132), QRS score was correlated well with TPD (r = 0.81, p < 0.001). This good correlation was found even in patients with TPD ≤40 % (n = 126) or in patients with TPD ≤30 % (n = 117). In overall patients, MI size estimated by QRS score was 7.0 ± 8.8 %, which was significantly smaller than TPD, 11.4 ± 14.0 % (p < 0.001). Bland-Altman plot showed that there was an increasing difference between QRS score and TPD with increasing MI size. When Blant-Altman plots were applied to patients with TPD ≤40 % and further in patients with TPD ≤30 %, the difference between QRS score and TPD became smaller, and the agreement became better. In overall patients, QRS score was correlated well with QGS measurements, such as end-diastolic volume (r = 0.62, p < 0.001), end-systolic volume (r = 0.67, p < 0.001), or ejection fraction (r = -0.73, p < 0.001). Our results suggest that QRS score reflects TPD well in patients with prior anterior MI, whose TPD is less than approximately 30 % even in the coronary intervention era.

  18. Interactive Screen Experiments with Single Photons

    Science.gov (United States)

    Bronner, Patrick; Strunz, Andreas; Silberhorn, Christine; Meyn, Jan-Peter

    2009-01-01

    Single photons are used for fundamental quantum physics experiments as well as for applications. Originally being a topic of advance courses, such experiments are increasingly a subject of undergraduate courses. We provide interactive screen experiments (ISE) for supporting the work in a real laboratory, and for students who do not have access to…

  19. Single Photon Experiments and Quantum Complementarity

    Directory of Open Access Journals (Sweden)

    Georgiev D. D.

    2007-04-01

    Full Text Available Single photon experiments have been used as one of the most striking illustrations of the apparently nonclassical nature of the quantum world. In this review we examine the mathematical basis of the principle of complementarity and explain why the Englert-Greenberger duality relation is not violated in the configurations of Unruh and of Afshar.

  20. Ultrafast time measurements by time-correlated single photon counting coupled with superconducting single photon detector

    Energy Technology Data Exchange (ETDEWEB)

    Shcheslavskiy, V., E-mail: vis@becker-hickl.de; Becker, W. [Becker & Hickl GmbH, Nahmitzer Damm 30, 12277 Berlin (Germany); Morozov, P.; Divochiy, A. [Scontel, Rossolimo St., 5/22-1, Moscow 119021 (Russian Federation); Vakhtomin, Yu. [Scontel, Rossolimo St., 5/22-1, Moscow 119021 (Russian Federation); Moscow State Pedagogical University, 1/1 M. Pirogovskaya St., Moscow 119991 (Russian Federation); Smirnov, K. [Scontel, Rossolimo St., 5/22-1, Moscow 119021 (Russian Federation); Moscow State Pedagogical University, 1/1 M. Pirogovskaya St., Moscow 119991 (Russian Federation); National Research University Higher School of Economics, 20 Myasnitskaya St., Moscow 101000 (Russian Federation)

    2016-05-15

    Time resolution is one of the main characteristics of the single photon detectors besides quantum efficiency and dark count rate. We demonstrate here an ultrafast time-correlated single photon counting (TCSPC) setup consisting of a newly developed single photon counting board SPC-150NX and a superconducting NbN single photon detector with a sensitive area of 7 × 7 μm. The combination delivers a record instrument response function with a full width at half maximum of 17.8 ps and system quantum efficiency ∼15% at wavelength of 1560 nm. A calculation of the root mean square value of the timing jitter for channels with counts more than 1% of the peak value yielded about 7.6 ps. The setup has also good timing stability of the detector–TCSPC board.

  1. Room-temperature single-photon generation from solitary dopants of carbon nanotubes

    Science.gov (United States)

    Ma, Xuedan; Hartmann, Nicolai F.; Baldwin, Jon K. S.; Doorn, Stephen K.; Htoon, Han

    2015-08-01

    On-demand single-photon sources capable of operating at room temperature and the telecom wavelength range of 1,300-1,500 nm hold the key to the realization of novel technologies that span from sub-diffraction imaging to quantum key distribution and photonic quantum information processing. Here, we show that incorporation of undoped (6,5) single-walled carbon nanotubes into a SiO2 matrix can lead to the creation of solitary oxygen dopant states capable of fluctuation-free, room-temperature single-photon emission in the 1,100-1,300 nm wavelength range. We investigated the effects of temperature on photoluminescence emission efficiencies, fluctuations and decay dynamics of the dopant states and determined the conditions most suitable for the observation of single-photon emission. This emission can in principle be extended to 1,500 nm by doping of smaller-bandgap single-walled carbon nanotubes. This easy tunability presents a distinct advantage over existing defect centre single-photon emitters (for example, diamond defect centres). Our SiO2-encapsulated sample also presents exciting opportunities to apply Si/SiO2-based micro/nano-device fabrication techniques in the development of electrically driven single-photon sources and integration of these sources into quantum photonic devices and networks.

  2. SINGLE: single photon sensitive cryogenic light detectors

    Science.gov (United States)

    Biassoni, Matteo; SINGLE Collaboration

    2017-09-01

    Thermal detectors operated at few mK as calorimeters are a powerful tool for the study of rare particle physics processes. In order to implement particle identification, light detection can be effectively performed by means of other thermal detectors operated as light sensors. This configuration can be used also in large scale, thousand-channels setups, but the light sensors must be sensitive enough to detect few, possibly a single, photons. The SINGLE project described here aims at producing silicon based, large area devices that can be operated as thermal detectors with single-photon sensitivity, and demonstrate the reliability of the performance, scalability of the production process and integrability with present and next generation cryogenic experiments for the search for rare events.

  3. In vivo effects of olanzapine on striatal dopamine D{sub 2}/D{sub 3} receptor binding in schizophrenic patients: an iodine-123 iodobenzamide single-photon emission tomography study

    Energy Technology Data Exchange (ETDEWEB)

    Dresel, S.; Rossmueller, B.; Hahn, K.; Tatsch, K. [Department of Nuclear Medicine, University of Munich (Germany); Mager, T.; Meisenzahl, E.; Moeller, H.J. [Department of Psychiatry, University of Munich (Germany)

    1999-08-01

    Olanzapine is a new atypical antipsychotic agent that belongs to the same chemical class as clozapine. The pharmacological efficacy of olanzapine (in contrast to that of risperidone) has been shown to be comparable to that of clozapine, but olanzapine has the advantage of producing a less pronounced bone marrow depressing effect than clozapine. The specific aims of this study were (a) to assess dopamine D{sub 2}/D{sub 3} receptor availability in patients treated with olanzapine by means of iodine-123 iodobenzamide [{sup 123}I]IBZM single-photon emission tomography (SPET), (b) to compare the results with findings of [{sup 123}I]IBZM SPET in patients under treatment with risperidone and (c) to correlate the results with the occurrance of extrapyramidal side-effects (EPMS). Brain SPET scans were performed in 20 schizophrenic patients (DSM III R) at 2 h after i.v. administration of 185 MBq [{sup 123}I]IBZM. Images were acquired using a triple-head gamma camera (Picker Prism 3000 XP). For semiquantitative evaluation of D{sub 2}/D{sub 3} receptor binding, transverse slices corrected for attenuation were used to calculate specific uptake values [STR-BKG]/BKG (STR=striatum; BKG=background). The mean daily dose of olanzapine ranged from 0.05 to 0.6 mg/kg body weight. The dopamine D{sub 2}/D{sub 3} receptor binding was reduced in all patients treated with olanzapine. Specific IBZM binding [STR-BKG]/BKG ranged from 0.13 to 0.61 (normal controls >0.95). The decreased D{sub 2}/D{sub 3} receptor availability revealed an exponential dose-response relationship (r=-0.85, P<0.001). The slope of the curve was similar to that of risperidone and considerably higher than that of clozapine as compared with the results of a previously published study. EPMS were observed in only one patient, presenting with the lowest D{sub 2}/D{sub 3} availability. The frequency of EPMS induced by olanzapine (5%) was considerably lower than the frequency under risperidone treatment (40%). Our findings

  4. In vivo effects of olanzapine on striatal dopamine D[sub 2]/D[sub 3] receptor binding in schizophrenic patients: an iodine-123 iodobenzamide single-photon emission tomography study

    Energy Technology Data Exchange (ETDEWEB)

    Dresel, S.; Rossmueller, B.; Hahn, K.; Tatsch, K. (Department of Nuclear Medicine, University of Munich (Germany)); Mager, T.; Meisenzahl, E.; Moeller, H.J. (Department of Psychiatry, University of Munich (Germany))

    1999-08-01

    Olanzapine is a new atypical antipsychotic agent that belongs to the same chemical class as clozapine. The pharmacological efficacy of olanzapine (in contrast to that of risperidone) has been shown to be comparable to that of clozapine, but olanzapine has the advantage of producing a less pronounced bone marrow depressing effect than clozapine. The specific aims of this study were (a) to assess dopamine D[sub 2]/D[sub 3] receptor availability in patients treated with olanzapine by means of iodine-123 iodobenzamide [[sup 123]I]IBZM single-photon emission tomography (SPET), (b) to compare the results with findings of [[sup 123]I]IBZM SPET in patients under treatment with risperidone and (c) to correlate the results with the occurrance of extrapyramidal side-effects (EPMS). Brain SPET scans were performed in 20 schizophrenic patients (DSM III R) at 2 h after i.v. administration of 185 MBq [[sup 123]I]IBZM. Images were acquired using a triple-head gamma camera (Picker Prism 3000 XP). For semiquantitative evaluation of D[sub 2]/D[sub 3] receptor binding, transverse slices corrected for attenuation were used to calculate specific uptake values [STR-BKG]/BKG (STR=striatum; BKG=background). The mean daily dose of olanzapine ranged from 0.05 to 0.6 mg/kg body weight. The dopamine D[sub 2]/D[sub 3] receptor binding was reduced in all patients treated with olanzapine. Specific IBZM binding [STR-BKG]/BKG ranged from 0.13 to 0.61 (normal controls >0.95). The decreased D[sub 2]/D[sub 3] receptor availability revealed an exponential dose-response relationship (r=-0.85, P<0.001). The slope of the curve was similar to that of risperidone and considerably higher than that of clozapine as compared with the results of a previously published study. EPMS were observed in only one patient, presenting with the lowest D[sub 2]/D[sub 3] availability. The frequency of EPMS induced by olanzapine (5%) was considerably lower than the frequency under risperidone treatment (40%). Our findings

  5. Single Photon Thermal Ionization of C60

    Science.gov (United States)

    Hansen, Klavs; Richter, Robert; Alagia, Michele; Stranges, Stefano; Schio, Luca; Salén, Peter; Yatsyna, Vasyl; Feifel, Raimund; Zhaunerchyk, Vitali

    2017-03-01

    We report on experiments which show that C60 can ionize in an indirect, quasithermal boiloff process after absorption of a single photon. The process involves a large number of incoherently excited valence electrons and yields electron spectra with a Boltzmann distribution with temperatures exceeding 104 K . It is expected to be present for other molecules and clusters with a comparatively large number of valence electrons. The astrophysical consequences are briefly discussed.

  6. Estudio de la reserva de perfusión miocárdica mediante tomografía de emisión de fotón único con talio-201 y estrés farmacológico con adenosina trifosfato en pacientes con factores de riesgo cardiovascular

    National Research Council Canada - National Science Library

    Huelmos Rodrigo, Ana; Alegría Ezquerra, Eduardo; Martínez Caro, Diego; José García Velloso, María; Ángel Richter Echevarría, José

    1997-01-01

    ...- nificativamente más bajas en los individuos con factores de riesgo cardiovascular que en los suje- aquellos con enfermedad coronaria, lo que puede sugerir que se encuentran en una etapa precoz de aterosclerosis. STUDY OF MYOCARDIAL PERFUSION RESERVE WITH SINGLE-PHOTON-EMISSION COMPUTED TOMOGRAPHY WITH THALLIUM-201 AND PHARMACOLOGICAL STRESS W...

  7. Coherent single-photon absorption by single emitters coupled to one-dimensional nanophotonic waveguides

    DEFF Research Database (Denmark)

    Chen, Yuntian; Wubs, Martijn; Mørk, Jesper

    2011-01-01

    solutions for the dynamics of absorption, with maximum atomic excitation . We furthermore propose a terminated waveguide to aid the single-photon absorption. We found that for an emitter placed at an optimal distance from the termination, the maximum atomic excitation due to an incident single......We study the dynamics of single-photon absorption by a single emitter coupled to a one-dimensional waveguide that simultaneously provides channels for spontaneous emission (SE) decay and a channel for the input photon. We have developed a time-dependent theory that allows us to specify any input......-photon wavepacket can exceed 70%. This high value is a direct consequence of the high SE β-factor for emission into the waveguide. Finally, we have also explored whether waveguide dispersion could aid single-photon absorption by pulse shaping. For a Gaussian input wavepacket, we found that the absorption efficiency...

  8. Electrically driven quantum dot-micropillar single photon source with 34% overall efficiency

    Science.gov (United States)

    Heindel, T.; Schneider, C.; Lermer, M.; Kwon, S. H.; Braun, T.; Reitzenstein, S.; Höfling, S.; Kamp, M.; Forchel, A.

    2010-01-01

    We report on triggered single photon emission from low mode volume electrically driven quantum dot-micropillar cavities at repetition rates of up to 220 MHz. Due to an optimized layout of the doped planar microcavity and an advanced lateral current injection scheme, highly efficient single photon sources are realized. While g(2)(0)-values as low as 0.13±0.05 and a Purcell factor of 4 are observed for a 2.0 μm diameter micropillar, single photon emission at a rate of (35±7) MHz and an overall efficiency of (34±7)% are demonstrated for a 3.0 μm device.

  9. Multimodal imaging analysis of single-photon emission computed tomography and magnetic resonance tomography for improving diagnosis of Parkinson's disease; Multimodale SPECT- und MRT-Bilddatenanalyse zur Verbesserung der Diagnostik des idiopathischen Parkinson-Syndroms

    Energy Technology Data Exchange (ETDEWEB)

    Barthel, H.; Georgi, P. [Leipzig Univ. (Germany). Klinik und Poliklinik fuer Nuklearmedizin; Mueller, U.; Waechter, T.; Murai, T. [Max-Planck-Inst. fuer Neuropsychologische Forschung, Leipzig (Germany); Slomka, P. [Universitaet West-Ontario, London (Canada). Abt. fuer Nuklearmedizin; Dannenberg, C.; Kahn, T. [Leipzig Univ. (Germany). Klinik und Poliklinik fuer Diagnostische Radiologie

    2000-10-01

    Parkinson's disease (PD) is characterized by a degeneration of nigrostriated dopaminergic neurons, which can be imaged with {sup 123}I-labeled 2{beta}-carbomethoxy-3{beta}-(4-iodophenyl) tropane ([{sup 123}I]{beta}-CIT) and single-photon emission computed tomography (SPECT). However, the quality of the region of interest (ROI) technique used for quantitative analysis of SPECT data is compromised by limited anatomical information in the images. We investigated whether the diagnosis of PD can be improved by combining the use of SPECT images with morphological image data from magnetic resonance imaging (MRI)/computed tomography (CT). We examined 27 patients (8 men, 19 women; aged 55{+-}13 years) with PD (Hoehn and Yahr stage 2.1{+-}0.8) by high-resolution [{sup 123}I]{beta}-CIT SPECT (185-200 MBq, Ceraspect camera). SPECT images were analyzed both by a unimodal technique (ROIs defined directly within the SPECT studies) and a multimodal technique (ROIs defined within individual MRI/CT studies and transferred to the corresponding interactively coregistered SPECT studies). [{sup 123}I]{beta}-CIT binding ratios (cerebellum as reference), which were obtained for heads of caudate nuclei (CA), putamina (PU), and global striatal structures were compared with clinical parameters. Differences between contra- and ipsilateral (related to symptom dominance) striatal [{sup 123}I]{beta}-CIT binding ratios proved to be larger in the multimodal ROI technique than in the unimodal approach (e.g., for PU: 1.2*** vs. 0.7**). Binding ratios obtained by the unimodal ROI technique were significantly correlated with those of the multimodal technique (e.g., for CA: y=0.97x+2.8; r=0.70; P<0.001). Concerning the correlations between SPECT data and clinical parameters, the significance levels in the multimodal ROI technique exceeded those of the unimodal technique, for example, for the correlation between CA and the UPDRS{sub com} subscore (r=-0.49* vs. -0.32). These results show that the

  10. Boson Sampling with Single-Photon Fock States from a Bright Solid-State Source.

    Science.gov (United States)

    Loredo, J C; Broome, M A; Hilaire, P; Gazzano, O; Sagnes, I; Lemaitre, A; Almeida, M P; Senellart, P; White, A G

    2017-03-31

    A boson-sampling device is a quantum machine expected to perform tasks intractable for a classical computer, yet requiring minimal nonclassical resources as compared to full-scale quantum computers. Photonic implementations to date employed sources based on inefficient processes that only simulate heralded single-photon statistics when strongly reducing emission probabilities. Boson sampling with only single-photon input has thus never been realized. Here, we report on a boson-sampling device operated with a bright solid-state source of single-photon Fock states with high photon-number purity: the emission from an efficient and deterministic quantum dot-micropillar system is demultiplexed into three partially indistinguishable single photons, with a single-photon purity 1-g^{(2)}(0) of 0.990±0.001, interfering in a linear optics network. Our demultiplexed source is between 1 and 2 orders of magnitude more efficient than current heralded multiphoton sources based on spontaneous parametric down-conversion, allowing us to complete the boson-sampling experiment faster than previous equivalent implementations.

  11. Room temperature single photon source using fiber-integrated hexagonal boron nitride

    Science.gov (United States)

    Vogl, Tobias; Lu, Yuerui; Lam, Ping Koy

    2017-07-01

    Single photons are a key resource for quantum optics and optical quantum information processing. The integration of scalable room temperature quantum emitters into photonic circuits remains to be a technical challenge. Here we utilize a defect center in hexagonal boron nitride (hBN) attached by Van der Waals force onto a multimode fiber as a single photon source. We perform an optical characterization of the source in terms of spectrum, state lifetime, power saturation and photostability. A special feature of our source is that it allows for easy switching between fiber-coupled and free space single photon generation modes. In order to prove the quantum nature of the emission we measure the second-order correlation function {{g}(2)}≤ft(τ \\right) . For both fiber-coupled and free space emission, the {{g}(2)}≤ft(τ \\right) dips below 0.5 indicating operation in the single photon regime. The results so far demonstrate the feasibility of 2D material single photon sources for scalable photonic quantum information processing.

  12. Design of Si/SiO2 micropillar cavities for Purcell-enhanced single photon emission at 1.55 μm from InAs/InP quantum dots.

    Science.gov (United States)

    Song, Hai-Zhi; Takemoto, Kazuya; Miyazawa, Toshiyuki; Takatsu, Motomu; Iwamoto, Satoshi; Yamamoto, Tsuyoshi; Arakawa, Yasuhiko

    2013-09-01

    Numerical simulations were carried out on micropillar cavities consisting of Si/SiO2 distributed Bragg reflectors (DBRs) with an InP spacer layer. Owing to a large refractive index contrast of ~2 in DBRs, cavities with just 4/6.5 top/bottom DBR pairs that give a low pillar height (~4.5 μm), have noticeable Purcell-enhancement effect in the 1.55-μm band. With careful designs on cavities with diameters of ~2.30 μm, a quality factor of up to 3300, a nominal Purcell factor of up to 110, and an output efficiency of ~60% are obtainable. These results ensure improvement of operation frequency and enhancement of photon indistinguishability for 1.55-μm single photon sources based on InAs/InP quantum dots.

  13. Changing optical band structure with single photons

    Science.gov (United States)

    Albrecht, Andreas; Caneva, Tommaso; Chang, Darrick E.

    2017-11-01

    Achieving strong interactions between individual photons enables a wide variety of exciting possibilities in quantum information science and many-body physics. Cold atoms interfaced with nanophotonic structures have emerged as a platform to realize novel forms of nonlinear interactions. In particular, when atoms are coupled to a photonic crystal waveguide, long-range atomic interactions can arise that are mediated by localized atom-photon bound states. We theoretically show that in such a system, the absorption of a single photon can change the band structure for a subsequent photon. This occurs because the first photon affects the atoms in the chain in an alternating fashion, thus leading to an effective period doubling of the system and a new optical band structure for the composite atom-nanophotonic system. We demonstrate how this mechanism can be engineered to realize a single-photon switch, where the first incoming photon switches the system from being highly transmissive to highly reflective, and analyze how signatures can be observed via non-classical correlations of the outgoing photon field.

  14. Generating single photons at gigahertz modulation-speed using electrically controlled quantum dot microlenses

    Energy Technology Data Exchange (ETDEWEB)

    Schlehahn, A.; Schmidt, R.; Hopfmann, C.; Schulze, J.-H.; Strittmatter, A.; Heindel, T., E-mail: tobias.heindel@tu-berlin.de; Reitzenstein, S. [Institut für Festkörperphysik, Technische Universität Berlin, 10623 Berlin (Germany); Gantz, L.; Schmidgall, E. R.; Gershoni, D. [The Physics Department and the Solid State Institute, Technion-Israel Institute of Technology, 32000 Haifa (Israel)

    2016-01-11

    We report on the generation of single-photon pulse trains at a repetition rate of up to 1 GHz. We achieve this speed by modulating the external voltage applied on an electrically contacted quantum dot microlens, which is optically excited by a continuous-wave laser. By modulating the photoluminescence of the quantum dot microlens using a square-wave voltage, single-photon emission is triggered with a response time as short as (281 ± 19) ps, being 6 times faster than the radiative lifetime of (1.75 ± 0.02) ns. This large reduction in the characteristic emission time is enabled by a rapid capacitive gating of emission from the quantum dot, which is placed in the intrinsic region of a p-i-n-junction biased below the onset of electroluminescence. Here, since our circuit acts as a rectifying differentiator, the rising edge of the applied voltage pulses triggers the emission of single photons from the optically excited quantum dot. The non-classical nature of the photon pulse train generated at GHz-speed is proven by intensity autocorrelation measurements with g{sup (2)}(0) = 0.3 ± 0.1. Our results combine optical excitation with fast electrical gating and thus show promise for the generation of indistinguishable single photons at rates exceeding the limitations set by the intrinsic radiative lifetime.

  15. Generating single photons at gigahertz modulation-speed using electrically controlled quantum dot microlenses

    Science.gov (United States)

    Schlehahn, A.; Schmidt, R.; Hopfmann, C.; Schulze, J.-H.; Strittmatter, A.; Heindel, T.; Gantz, L.; Schmidgall, E. R.; Gershoni, D.; Reitzenstein, S.

    2016-01-01

    We report on the generation of single-photon pulse trains at a repetition rate of up to 1 GHz. We achieve this speed by modulating the external voltage applied on an electrically contacted quantum dot microlens, which is optically excited by a continuous-wave laser. By modulating the photoluminescence of the quantum dot microlens using a square-wave voltage, single-photon emission is triggered with a response time as short as (281 ± 19) ps, being 6 times faster than the radiative lifetime of (1.75 ± 0.02) ns. This large reduction in the characteristic emission time is enabled by a rapid capacitive gating of emission from the quantum dot, which is placed in the intrinsic region of a p-i-n-junction biased below the onset of electroluminescence. Here, since our circuit acts as a rectifying differentiator, the rising edge of the applied voltage pulses triggers the emission of single photons from the optically excited quantum dot. The non-classical nature of the photon pulse train generated at GHz-speed is proven by intensity autocorrelation measurements with g(2)(0) = 0.3 ± 0.1. Our results combine optical excitation with fast electrical gating and thus show promise for the generation of indistinguishable single photons at rates exceeding the limitations set by the intrinsic radiative lifetime.

  16. Near-unity efficiency, single-photon sources based on tapered photonic nanowires

    DEFF Research Database (Denmark)

    Bleuse, Joël; Munsch, Mathieu; Claudon, Julien

    2012-01-01

    Single-photon emission from excitons in InAs Quantum Dots (QD) embedded in GaAs Tapered Photonic Wires (TPW) already demonstrated a 0.72 collection efficiency, with TPWs were the apex is the sharp end of the cone. Going to alternate designs, still based on the idea of the adiabatic deconfinement...

  17. Number-Resolved Single-Photon Detection with Ultralow Noise van der Waals Hybrid.

    Science.gov (United States)

    Roy, Kallol; Ahmed, Tanweer; Dubey, Harshit; Sai, T Phanindra; Kashid, Ranjit; Maliakal, Shruti; Hsieh, Kimberly; Shamim, Saquib; Ghosh, Arindam

    2018-01-01

    Van der Waals hybrids of graphene and transition metal dichalcogenides exhibit an extremely large response to optical excitation, yet counting of photons with single-photon resolution is not achieved. Here, a dual-gated bilayer graphene (BLG) and molybdenum disulphide (MoS 2 ) hybrid are demonstrated, where opening a band gap in the BLG allows extremely low channel (receiver) noise and large optical gain (≈10 10 ) simultaneously. The resulting device is capable of unambiguous determination of the Poissonian emission statistics of an optical source with single-photon resolution at an operating temperature of 80 K, dark count rate 0.07 Hz, and linear dynamic range of ≈40 dB. Single-shot number-resolved single-photon detection with van der Waals heterostructures may impact multiple technologies, including the linear optical quantum computation. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Computational Modeling of Photonic Crystal Microcavity Single-Photon Emitters

    Science.gov (United States)

    Saulnier, Nicole A.

    Conventional cryptography is based on algorithms that are mathematically complex and difficult to solve, such as factoring large numbers. The advent of a quantum computer would render these schemes useless. As scientists work to develop a quantum computer, cryptographers are developing new schemes for unconditionally secure cryptography. Quantum key distribution has emerged as one of the potential replacements of classical cryptography. It relics on the fact that measurement of a quantum bit changes the state of the bit and undetected eavesdropping is impossible. Single polarized photons can be used as the quantum bits, such that a quantum system would in some ways mirror the classical communication scheme. The quantum key distribution system would include components that create, transmit and detect single polarized photons. The focus of this work is on the development of an efficient single-photon source. This source is comprised of a single quantum dot inside of a photonic crystal microcavity. To better understand the physics behind the device, a computational model is developed. The model uses Finite-Difference Time-Domain methods to analyze the electromagnetic field distribution in photonic crystal microcavities. It uses an 8-band k · p perturbation theory to compute the energy band structure of the epitaxially grown quantum dots. We discuss a method that combines the results of these two calculations for determining the spontaneous emission lifetime of a quantum dot in bulk material or in a microcavity. The computational models developed in this thesis are used to identify and characterize microcavities for potential use in a single-photon source. The computational tools developed are also used to investigate novel photonic crystal microcavities that incorporate 1D distributed Bragg reflectors for vertical confinement. It is found that the spontaneous emission enhancement in the quasi-3D cavities can be significantly greater than in traditional suspended slab

  19. Spectral compression of single-photon-level laser pulse

    Science.gov (United States)

    Li, Yuanhua; Xiang, Tong; Nie, Yiyou; Sang, Minghuang; Chen, Xianfeng

    2017-02-01

    We experimentally demonstrate that the bandwidth of single photons laser pulse is compressed by a factor of 58 in a periodically poled lithium niobate (PPLN) waveguide chip. A positively chirped single photons laser pulse and a negatively chirped classical laser pulse are employed to produce a narrowband single photon pulse with new frequency through sum-frequency generation. In our experiment, the frequency and bandwidth of single photons at 1550 nm are simultaneously converted. Our results mark a critical step towards the realization of coherent photonic interface between quantum communication at 1550 nm and quantum memory in the near-visible window.

  20. A single photon emission computed tomograph based on a limited dumber of detectors for fluid flow visualization; Tomographie d'emission gamma a partir d'un nombre limite de detecteurs appliquee a la visualisation d'ecoulements

    Energy Technology Data Exchange (ETDEWEB)

    Legoupil, S

    1999-07-01

    We present in this work a method for fluid flow visualization in a system using radioactive tracers. The method is based on single photon emission computed tomography techniques, applied to a limited number of discrete detectors. We propose in this work a method for the estimation of the transport matrix of photons, associated to the acquisition system.This method is based on the modelization of profiles acquired for a set of point sources located in the imaged volume. Monte Carlo simulations allow to separate scattered photons from those directly collected by the system. The influence of the energy tracer is exposed. The reconstruction method is based on the maximum likelihood - expectation maximization algorithm. An experimental device, based on 36 detectors was realised for the visualization of water circulation in a vessel. A video monitoring allows to visualize the dye water tracer. Dye and radioactive tracers are injected simultaneously in a water flow circulating in the vessel. Reconstructed and video images are compared. Quantitative and qualitative analysis show that fluid flow visualization is feasible with a limited number of detectors. This method can be applied for system involving circulations of fluids. (author)

  1. Pushing the limits of single-photon information encoding

    NARCIS (Netherlands)

    Hummel, T.; Tentrup, Tristan Bernhard Horst; Uppu, Ravitej; Mosk, Allard; Pinkse, Pepijn Willemszoon Harry

    2016-01-01

    Single photons are the carrier of choice in many quantum information processing protocols. Encoding information in a high-dimensional Hilbert space allows for the transfer of more than one bit of information per photon. We use a spatial light modulator (SLM) to direct the single photons to distinct

  2. Clinical impact of (11)C-Pittsburgh compound-B positron emission tomography carried out in addition to magnetic resonance imaging and single-photon emission computed tomography on the diagnosis of Alzheimer's disease in patients with dementia and mild cognitive impairment.

    Science.gov (United States)

    Omachi, Yoshie; Ito, Kimiteru; Arima, Kunimasa; Matsuda, Hiroshi; Nakata, Yasuhiro; Sakata, Masuhiro; Sato, Noriko; Nakagome, Kazuyuki; Motohashi, Nobutaka

    2015-12-01

    The purpose of this study was to evaluate the clinical impact of addition of [(11)C]Pittsburgh compound-B positron emission tomography ((11)C-PiB PET) on routine clinical diagnosis of Alzheimer's disease (AD) dementia and mild cognitive impairment (MCI), and to assess diagnostic agreement between clinical criteria and research criteria of the National Institute on Aging-Alzheimer's Association. The diagnosis in 85 patients was made according to clinical criteria. Imaging examinations, including both magnetic resonance imaging and single-photon emission computed tomography/computed tomography to identify neuronal injury (NI), and (11)C-PiB PET to identify amyloid were performed, and all subjects were re-categorized according to the research criteria. Among 40 patients with probable AD dementia (ProAD), 37 were NI-positive, 29 were (11)C-PiB-positive, and 27 who were both NI- and (11C-PiB-positive were categorized as having 'ProAD dementia with a high level of evidence of the AD pathophysiological process'. Among 20 patients with possible AD dementia (PosAD), 17 were NI-positive, and six who were both NI- and (11)C-PiB-positive were categorized as having 'PosAD with evidence of the AD pathophysiological process'. Among 25 patients with MCI, 18 were NI-positive, 13 were (11)C-PiB-positive, and 10 who were both NI- and (11)C-PiB-positive were categorized as having 'MCI due to AD-high likelihood'. Diagnostic concordance between clinical criteria and research criteria may not be high in this study. (11)C-PiB PET may be of value in making the diagnosis of dementia and MCI in cases with high diagnostic uncertainty. © 2015 The Authors. Psychiatry and Clinical Neurosciences © 2015 Japanese Society of Psychiatry and Neurology.

  3. Dead Time of Single Photon Avalanche Diodes

    Energy Technology Data Exchange (ETDEWEB)

    Neri, L., E-mail: lorenzo.neri@ct.infn.it [INFN Laboratori Nazionali del Sud, via S.Sofia 62, I-95125, Catania (Italy); Universita degli Studi di Catania, via S.Sofia 64, I-95123, Catania (Italy); Tudisco, S. [INFN Laboratori Nazionali del Sud, via S.Sofia 62, I-95125, Catania (Italy); Musumeci, F.; Scordino, A. [Universita degli Studi di Catania, via S.Sofia 64, I-95123, Catania (Italy); Fallica, G.; Mazzillo, M. [ST-Microelectronics, stradale Primosole 50, I-95100, Catania (Italy); Zimbone, M. [Universita degli Studi di Catania, via S.Sofia 64, I-95123, Catania (Italy)

    2011-06-15

    Single Photon Avalanche Diode (SPAD) is the new generation of Geiger-Muller counter device developed in semiconductor technology [S. Privitera et al. Sensors Journal, vol 8 Iss. 8 (2008) 4636; S. Tudisco et al. IEEE Sensors Journal vol 8 ISS 7-8 (2008) 1324; S. Cova et al. Applied Optics 35 (1996) 1956]. Physical dead time model and noise production process has been analyzed and their corrections have been performed [S.H. Lee, R.P. Gardner, M. Jae, Nucl. Instr. and Meth. in Phys. Res. B 263 (2007) 46]. We have been able to extract the real amount of incident photon rate up to 10{sup 7}cps using a device with 0.97{mu}s total deadtime. We also developed the equation of the noise count rate vs incoming photon rate, supported by Montecarlo simulation and experimental data. We marked the difference between dark rate and noise count rate, and introduced the noise rate inside the hybrid deadtime equation used for SPAD device.

  4. A four-pixel single-photon pulse-position array fabricated from WSi superconducting nanowire single-photon detectors

    Energy Technology Data Exchange (ETDEWEB)

    Verma, V. B., E-mail: verma@nist.gov; Horansky, R.; Lita, A. E.; Mirin, R. P.; Nam, S. W. [National Institute of Standards and Technology, 325 Broadway, Boulder, Colorado 80305 (United States); Marsili, F.; Stern, J. A.; Shaw, M. D. [Jet Propulsion Laboratory, 4800 Oak Grove Dr., Pasadena, California 91109 (United States)

    2014-02-03

    We demonstrate a scalable readout scheme for an infrared single-photon pulse-position camera consisting of WSi superconducting nanowire single-photon detectors. For an N × N array, only 2 × N wires are required to obtain the position of a detection event. As a proof-of-principle, we show results from a 2 × 2 array.

  5. Angular distribution of single-photon superradiance in a dilute and cold atomic ensemble

    Science.gov (United States)

    Kuraptsev, A. S.; Sokolov, I. M.; Havey, M. D.

    2017-08-01

    On the basis of a quantum microscopic approach we study the dynamics of the afterglow of a dilute Gaussian atomic ensemble excited by pulsed radiation. Taking into account the vector nature of the electromagnetic field we analyze in detail the angular and polarization distribution of single-photon superradiance of such an ensemble. The dependence of the angular distribution of superradiance on the length of the pulse and its carrier frequency as well as on the size and the shape of the atomic clouds is studied. We show that there is substantial dependence of the superradiant emission on the polarization and the direction of fluorescence. We observe essential peculiarities of superradiance in the region of the forward diffraction zone and in the area of the coherent backscattering cone. We demonstrate that there are directions for which the rate of fluorescence is several times more than the decay rate of the timed-Dicke state. We show also that single-photon superradiance can be excited by incoherent excitation when atomic polarization in the ensemble is absent. Besides a quantum microscopic approach, we analyze single-photon superradiance on the basis of the theory of incoherent multiple scattering in optically thick media (random walk theory). In the case of very short resonant and long nonresonant pulses we derive simple analytical expressions for the decay rate of single-photon superradiance for incoherent fluorescence in an arbitrary direction.

  6. Quantum non-Gaussian Depth of Single-Photon States.

    Science.gov (United States)

    Straka, Ivo; Predojević, Ana; Huber, Tobias; Lachman, Lukáš; Butschek, Lorenz; Miková, Martina; Mičuda, Michal; Solomon, Glenn S; Weihs, Gregor; Ježek, Miroslav; Filip, Radim

    2014-11-28

    We introduce and experimentally explore the concept of the non-Gaussian depth of single-photon states with a positive Wigner function. The depth measures the robustness of a single-photon state against optical losses. The directly witnessed quantum non-Gaussianity withstands significant attenuation, exhibiting a depth of 18 dB, while the nonclassicality remains unchanged. Quantum non-Gaussian depth is an experimentally approachable quantity that is much more robust than the negativity of the Wigner function. Furthermore, we use it to reveal significant differences between otherwise strongly nonclassical single-photon sources.

  7. Deterministic Integration of Single Photon Sources in Silicon Based Photonic Circuits.

    Science.gov (United States)

    Zadeh, Iman Esmaeil; Elshaari, Ali W; Jöns, Klaus D; Fognini, Andreas; Dalacu, Dan; Poole, Philip J; Reimer, Michael E; Zwiller, Val

    2016-04-13

    A major step toward fully integrated quantum optics is the deterministic incorporation of high quality single photon sources in on-chip optical circuits. We show a novel hybrid approach in which preselected III-V single quantum dots in nanowires are transferred and integrated in silicon based photonic circuits. The quantum emitters maintain their high optical quality after integration as verified by measuring a low multiphoton probability of 0.07 ± 0.07 and emission line width as narrow as 3.45 ± 0.48 GHz. Our approach allows for optimum alignment of the quantum dot light emission to the fundamental waveguide mode resulting in very high coupling efficiencies. We estimate a coupling efficiency of 24.3 ± 1.7% from the studied single-photon source to the photonic channel and further show by finite-difference time-domain simulations that for an optimized choice of material and design the efficiency can exceed 90%.

  8. Coupling and single-photon purity of a quantum dot-cavity system studied using hydrostatic pressure

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, P. Y.; Wu, X. F.; Ding, K.; Dou, X. M.; Zha, G. W.; Ni, H. Q.; Niu, Z. C.; Zhu, H. J.; Jiang, D. S. [State Key Laboratory of Superlattices and Microstructures, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083 (China); Zhao, C. L. [College of Physics and Electronic Information, Inner Mongolia University for Nationalities, Tongliao 028043 (China); Sun, B. Q., E-mail: bqsun@semi.ac.cn [State Key Laboratory of Superlattices and Microstructures, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083 (China); College of Physics and Electronic Information, Inner Mongolia University for Nationalities, Tongliao 028043 (China)

    2015-01-07

    We propose an approach to tune the emission of a single semiconductor quantum dot (QD) to couple with a planar cavity using hydrostatic pressure without inducing temperature variation during the process of measurement. Based on this approach, we studied the influence of cavity mode on the single-photon purity of an InAs/GaAs QD. Our measurement demonstrates that the single-photon purity degrades when the QD emission resonates with the cavity mode. This negative influence of the planar cavity is mainly caused by the cavity feeding effect.

  9. Design of diamond microcavities for single photon frequency down-conversion

    CERN Document Server

    Lin, Zin; Rodriguez, Alejandro W; Loncar, M

    2015-01-01

    We propose monolithic diamond cavities that can be used to convert color-center Fock-state single photons from emission wavelengths to telecommunication bands. We present a detailed theoretical description of the conversion process, analyzing important practical concerns such as nonlinear phase shifts and frequency mismatch. Our analysis predicts sustainable power requirements ($ \\lesssim 1~\\mathrm{W}$) for a chipscale nonlinear device with high conversion efficiencies.

  10. Category theoretic analysis of single-photon decision maker

    CERN Document Server

    Kim, Makoto Naruse Song-Ju; Berthel, Martin; Drezet, Aurélien; Huant, Serge; Hori, Hirokazu

    2016-01-01

    Decision making is a vital function in the era of artificial intelligence; however, its physical realizations and their theoretical fundamentals are not yet known. In our former study [Sci. Rep. 5, 513253 (2015)], we demonstrated that single photons can be used to make decisions in uncertain, dynamically changing environments. The multi-armed bandit problem was successfully solved using the dual probabilistic and particle attributes of single photons. Herein, we present the category theoretic foundation of the single-photon-based decision making, including quantitative analysis that agrees well with the experimental results. The category theoretic model unveils complex interdependencies of the entities of the subject matter in the most simplified manner, including a dynamically changing environment. In particular, the octahedral structure in triangulated categories provides a clear understanding of the underlying mechanisms of the single-photon decision maker. This is the first demonstration of a category the...

  11. Quantum key distribution in single-photon communication system

    Science.gov (United States)

    Tretyakov, D. B.; Kolyako, A. V.; Pleshkov, A. S.; Entin, V. M.; Ryabtsev, I. I.; Neizvestny, I. G.

    2016-09-01

    This paper presents a brief review of experimental studies in quantum cryptography and quantum key distribution by single photons in atmospheric and fiber-optic quantum communication channels. Two experimental setups for quantum key distribution developed at the Rzhanov Institute of Semiconductor Physics SB RAS are described. The dependence of the quantum key distribution rate on the average number of photons μ in the laser pulse was studied. For μ > 0.3, there is a discrepancy between theory and experiment. The reasons for this are, first, the nonzero probability of multiphoton pulses occurring in quantum transmission and counted as single photons by single-photon detectors and, second, the rejection of the cases where several single-photon detectors click simultaneously in quantum key sifting because the measurement result is not determined in these cases.

  12. Interaction of independent single photons based on integrated nonlinear optics.

    Science.gov (United States)

    Guerreiro, T; Pomarico, E; Sanguinetti, B; Sangouard, N; Pelc, J S; Langrock, C; Fejer, M M; Zbinden, H; Thew, R T; Gisin, N

    2013-01-01

    The parametric interaction of light beams in nonlinear materials is usually thought to be too weak to be observed when the fields involved are at the single-photon level. However, such single-photon level nonlinearity is not only fundamentally fascinating but holds great potential for emerging technologies and applications involving heralding entanglement at a distance. Here we use a high-efficiency waveguide to demonstrate the sum-frequency generation between a single photon and a single-photon level coherent state. The use of an integrated, solid state, room temperature device and telecom wavelengths makes this type of system directly applicable to future quantum communication technologies such as device-independent quantum key distribution.

  13. Secure communication with a heralded single-photon source

    Energy Technology Data Exchange (ETDEWEB)

    Trifonov, A; Zavriyev, A [MagiQ Technologies, Inc., 11 Ward Street 300, Somerville, MA 02143 (United States)

    2005-12-01

    Secure long distance communication over optical fibres requires robust data encryption. While the encryption itself can be conducted using classical algorithms, there is no unconditionally secure method of classical key distribution. Quantum key distribution (QKD), on the other hand, can provide users of the optical networks with unconditionally secure keys. Since QKD is based on single-photon transmission, one of the challenging tasks is to overcome the distance limitation imposed by the losses in optical fibres. In this work we show that single-photon based QKD outperforms the industry-standard weak coherent pulse approach. We also present our recent experimental results on building a heralded single-photon source based on spontaneous parametric down-conversion of CW light and discuss problems and challenges of heralded single-photon generation in the CW regime.

  14. Direct detection of a single photon by humans

    Science.gov (United States)

    Tinsley, Jonathan N.; Molodtsov, Maxim I.; Prevedel, Robert; Wartmann, David; Espigulé-Pons, Jofre; Lauwers, Mattias; Vaziri, Alipasha

    2016-01-01

    Despite investigations for over 70 years, the absolute limits of human vision have remained unclear. Rod cells respond to individual photons, yet whether a single-photon incident on the eye can be perceived by a human subject has remained a fundamental open question. Here we report that humans can detect a single-photon incident on the cornea with a probability significantly above chance. This was achieved by implementing a combination of a psychophysics procedure with a quantum light source that can generate single-photon states of light. We further discover that the probability of reporting a single photon is modulated by the presence of an earlier photon, suggesting a priming process that temporarily enhances the effective gain of the visual system on the timescale of seconds. PMID:27434854

  15. High-Performance Single-Photon Sources via Spatial Multiplexing

    Science.gov (United States)

    2014-01-01

    ingredient for tasks such as quantum cryptography , quantum repeater, quantum teleportation, quantum computing, and truly-random number generation. Recently...SECURITY CLASSIFICATION OF: Single photons sources are desired for many potential quantum information applications. One common method to produce...photons sources are desired for many potential quantum information applications. One common method to produce single photons is based on a “heralding

  16. Quantum private comparison employing single-photon interference

    Science.gov (United States)

    Liu, Bin; Xiao, Di; Huang, Wei; Jia, Heng-Yue; Song, Ting-Ting

    2017-07-01

    As a typical quantum cryptographic task between distrustful participants, quantum private comparison (QPC) has attracted a lot of attention in recent years. Here we propose two QPC protocols employing single-photon interference, a typical and interesting technology for quantum communications. Compared with the previous QPC protocols employing normal single states or entangled states, the proposed protocols achieve lower communication complexity utilizing the characteristics of single-photon interference. And we also proved the security of the proposed protocols in theory.

  17. Extending single-photon optimized superconducting transition edge sensors beyond the single-photon counting regime.

    Science.gov (United States)

    Gerrits, Thomas; Calkins, Brice; Tomlin, Nathan; Lita, Adriana E; Migdall, Alan; Mirin, Richard; Nam, Sae Woo

    2012-10-08

    Typically, transition edge sensors resolve photon number of up to 10 or 20 photons, depending on the wavelength and TES design. We extend that dynamic range up to 1000 photons, while maintaining sub-shot noise detection process uncertainty of the number of detected photons and beyond that show a monotonic response up to ≈ 6 · 10(6) photons in a single light pulse. This mode of operation, which heats the sensor far beyond its transition edge into the normal conductive regime, offers a technique for connecting single-photon-counting measurements to radiant-power measurements at picowatt levels. Connecting these two usually incompatible operating regimes in a single detector offers significant potential for directly tying photon counting measurements to conventional cryogenic radiometric standards. In addition, our measurements highlight the advantages of a photon-number state source over a coherent pulse source as a tool for characterizing such a detector.

  18. Thallium-201 uptake in a benign thymoma

    Energy Technology Data Exchange (ETDEWEB)

    Campeau, R.J.; Ey, E.H.; Varma, D.G.

    1986-07-01

    A 68-year-old woman was admitted with atypical angina. A chest radiograph showed an anterior mediastinal mass that was confirmed on CT. The mass was relatively avascular and separate from the heart and great vessels. She underwent stress thallium testing that demonstrated no exercise-induced ischemia; however, an abnormal focus of thallium activity was present in the anterior mediastinum on stress and redistribution images. Cardiac catheterization demonstrated a normal left ventriculogram, coronary arteries and thoracic aorta. Subsequent surgery and pathologic examination revealed the mass to be a benign thymoma arising in the right lobe of the thymus gland.

  19. A Variable Single Photon Plasmonic Beamsplitter

    DEFF Research Database (Denmark)

    Israelsen, Niels Møller; Kumar, Shailesh; Huck, Alexander

    Plasmonic structures can both be exploited for scaling down optical components beyond the diffraction limit and enhancing andcollecting the emission from a single dipole emitter. Here, we experimentally demonstrate adiabatic coupling between two silvernanowires using a nitrogen vacancy center as ...

  20. Highly efficient photonic nanowire single-photon sources for quantum information applications

    DEFF Research Database (Denmark)

    Gregersen, Niels; Claudon, J.; Munsch, M.

    2013-01-01

    Within the emerging field of optical quantum information processing, the current challenge is to construct the basic building blocks for the quantum computing and communication systems. A key component is the singlephoton source (SPS) capable of emitting single photons on demand. Ideally, the SPS...... must feature near-unity efficiency, where the efficiency is defined as the number of detected photons per trigger, the probability g(2)(τ=0) of multi-photon emission events should be 0 and the emitted photons are required to be indistinguishable. An optically or electrically triggered quantum light...... emitter, e.g. a nitrogen-vacancy center or a semiconductor quantum dot (QD), embedded in a solid-state semiconductor host material appears as an attractive platform for generating such single photons. However, for a QD in bulk material, the large index contrast at the semiconductor-air interface leads...

  1. Chromium single-photon emitters in diamond fabricated by ion implantation

    Science.gov (United States)

    Aharonovich, Igor; Castelletto, Stefania; Johnson, Brett C.; McCallum, Jeffrey C.; Simpson, David A.; Greentree, Andrew D.; Prawer, Steven

    2010-03-01

    Controlled fabrication and identification of bright single-photon emitters is at the heart of quantum optics. Here we demonstrate controlled engineering of a chromium bright single-photon source in bulk diamond by ion implantation. The Cr center has fully polarized emission with a zero-phonon line centered at 749 nm, full width at half maximum of 4 nm, an extremely short lifetime of ˜1ns , and a count rate of 0.5×106counts/s . By combining the polarization measurements and the vibronic spectra, a model of the center has been proposed consisting of one interstitial chromium atom with a transition dipole along one of the ⟨100⟩ directions.

  2. Bright single photon source based on self-aligned quantum dot–cavity systems

    DEFF Research Database (Denmark)

    Maier, Sebastian; Gold, Peter; Forchel, Alfred

    2014-01-01

    We report on a quasi-planar quantum-dot-based single-photon source that shows an unprecedented high extraction efficiency of 42% without complex photonic resonator geometries or post-growth nanofabrication. This very high efficiency originates from the coupling of the photons emitted by a quantum...... dot to a Gaussian shaped nanohill defect that naturally arises during epitaxial growth in a self-aligned manner. We investigate the morphology of these defects and characterize the photonic operation mechanism. Our results show that these naturally arising coupled quantum dot-defects provide a new...... avenue for efficient (up to 42% demonstrated) and pure (g2(0) value of 0.023) single-photon emission....

  3. Fast time-domain measurements on telecom single photons

    Science.gov (United States)

    Allgaier, Markus; Vigh, Gesche; Ansari, Vahid; Eigner, Christof; Quiring, Viktor; Ricken, Raimund; Brecht, Benjamin; Silberhorn, Christine

    2017-09-01

    Direct measurements on the temporal envelope of quantum light are a challenging task and not many examples are known because most classical pulse characterisation methods do not work on the single-photon level. Knowledge of both spectrum and timing can, however, give insights on properties that cannot be determined by the spectral intensity alone. While temporal measurements on single photons on timescales of tens of picoseconds are possible with superconducting photon detectors, and picosecond measurements have been performed using streak cameras, there are no commercial single-photon sensitive devices with femtosecond resolution available. While time-domain sampling using sum-frequency generation has already been exploited for such a measurement, inefficient conversion has necessitated long integration times to build the temporal profile. We demonstrate a highly efficient waveguided sum-frequency generation process in Lithium Niobate to measure the temporal envelope of single photons with femtosecond resolution with short enough acquisition time to provide a live-view of the measurement. We demonstrate the measurement technique and combine it with spectral measurements using a dispersive-fibre time-of-flight spectrometer to determine upper and lower bounds for the spectral purity of heralded single photons. The approach complements the joint spectral intensity measurements as a measure on the purity can be given without knowledge of the spectral phase.

  4. Single photon emission computed tomography (SPECT) and SPECT/low-dose computerized tomography did not increase sensitivity or specificity compared to planar bone scintigraphy for detection of bone metastases in advanced breast cancer.

    Science.gov (United States)

    Haraldsen, Ate; Bluhme, Henrik; Røhl, Lisbeth; Pedersen, Erik Morre; Jensen, Anders Bonde; Hansen, Eva Boysen; Nellemann, Hanne; Rasmussen, Finn; Morsing, Anni

    2016-01-01

    To evaluate and compare the diagnostic performance of whole-body planar bone scintigraphy (WBS), single photon emission computed tomography (SPECT), SPECT/low-dose computerized tomography (SPECT/ldCT) and SPECT/contrast enhanced diagnostic CT (SPECT/cdCT) in the staging of patients with advanced breast cancer. Seventy-eight patients with recurrence of biopsy-proven breast cancer and suspicion of disseminated disease were investigated with WBS, SPECT, SPECT/ldCT, SPECT/cdCT and MRI performed on the same day in this prospective study. Images were separately analysed in a blinded fashion by radiologists and nuclear medicine physicians regarding the presence of pathological findings. MRI served as reference standard. According to reference standard, 38 of 73 patients had bone metastases. The sensitivity was 87%, 87%, 79%, and 84% and specificity 63%, 71%, 63% and 83% for WBS, SPECT, SPECT/ldCT and SPECT/cdCT. A significantly increased specificity of SPECT/cdCT compared to WBS and SPECT/ldCT was found, and other parameters did not differ significantly between modalities. Additional two patients had bone metastases solely located outside the MRI scan field and seven patients had soft tissue metastases, but no skeletal changes on MRI. WBS, SPECT and SPECT/ldCT were less sensitive than MRI and equally specific for the detection of bone metastases in patients with advanced breast cancer. Based on our findings, we suggest that initial staging include WBS, MRI of the spine and CT for soft tissue evaluation. Further studies may clarify the potential benefits of whole-body MRI and 18F-NaF PET/CT or 18F-FDG PET/CT. © 2014 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  5. PET image reconstruction with system matrix based on point spread function derived from single photon incidence response

    CERN Document Server

    Xin, Fan; Ming-Kai, Yun; Xiao-Li, Sun; Xue-Xiang, Cao; Shuang-Quanm, Liu; Pei, Chai; Dao-Wu, Li; Long, Wei

    2014-01-01

    In positron emission tomography (PET) imaging, statistical iterative reconstruction (IR) techniques appear particularly promising since they can provide accurate physical model and geometric system description. The reconstructed image quality mainly depends on the system matrix model which describes the relationship between image space and projection space for the IR method. The system matrix can contain some physics factors of detection such as geometrical component and blurring component. Point spread function (PSF) is generally used to describe the blurring component. This paper proposes an IR method based on the PSF system matrix, which is derived from the single photon incidence response function. More specifically, the gamma photon incidence on a crystal array is simulated by the Monte Carlo (MC) simulation, and then the single photon incidence response functions are obtained. Subsequently, using the single photon incidence response functions, the coincidence blurring factor is acquired according to the...

  6. Investigating and Improving Student Understanding of Quantum Mechanics in the Context of Single Photon Interference

    Science.gov (United States)

    Marshman, Emily; Singh, Chandralekha

    2017-01-01

    Single photon experiments involving a Mach-Zehnder interferometer can illustrate the fundamental principles of quantum mechanics, e.g., the wave-particle duality of a single photon, single photon interference, and the probabilistic nature of quantum measurement involving single photons. These experiments explicitly make the connection between the…

  7. Impact of the dark path on quantum dot single photon emitters in small cavities

    Science.gov (United States)

    Kamide, Kenji; Iwamoto, Satoshi; Arakawa, Yasuhiko

    2014-10-01

    Incoherent pumping in quantum dots can create a biexciton state through two paths: via the formation of bright or dark exciton states. The latter, dark-pumping path is shown to enhance the probability of two-photon simultaneous emission and hence increase g(2)(0) by a factor ∝1/γS, due to the slow spin relaxation rate γS in quantum dots. The existence of the dark path is shown to impose a limitation on the single photon emission process, especially in nanocavities which exhibit a large exciton-cavity coupling and a Purcell enhancement for fast quantum telecommunications.

  8. Single photon superradiance and cooperative Lamb shift in an optoelectronic device

    CERN Document Server

    Frucci, Giulia; Vasanelli, Angela; Dailly, Baptiste; Todorov, Yanko; Sirtori, Carlo; Beaudoin, Grégoire; Sagnes, Isabelle

    2016-01-01

    Single photon superradiance is a strong enhancement of spontaneous emission appearing when a single excitation is shared between a large number of two-level systems. This enhanced rate can be accompanied by a shift of the emission frequency, the cooperative Lamb shift, issued from the exchange of virtual photons between the emitters. In this work we present a semiconductor optoelectronic device allowing the observation of these two phenomena at room temperature. We demonstrate experimentally and theoretically that plasma oscillations in spatially separated quantum wells interact through real and virtual photon exchange. This gives rise to a superradiant mode displaying a large cooperative Lamb shift.

  9. Photoconductance quantization in a single-photon detector

    Science.gov (United States)

    Kosaka, Hideo; Rao, Deepak S.; Robinson, Hans D.; Bandaru, Prabhakar; Sakamoto, Toshitsugu; Yablonovitch, Eli

    2002-05-01

    We have made a single-photon detector that relies on photoconductive gain in a narrow electron channel in an AlyGa1-yAs/GaAs two-dimensional electron gas. Given that the electron channel is one dimensional, the photoinduced conductance has plateaus at multiples of the quantum conductance 2e2/h. Superimposed on these broad conductance plateaus are many sharp, small, conductance steps associated with single-photon absorption events that produce individual photocarriers. This is a first step toward a photoconductive detector that could measure a single photon, while safely storing and protecting the spin degree of freedom of its photocarrier, but we have not actually achieved that goal.

  10. Quantum Probability Cancellation Due to a Single-Photon State

    Science.gov (United States)

    Ou, Z. Y.

    1996-01-01

    When an N-photon state enters a lossless symmetric beamsplitter from one input port, the photon distribution for the two output ports has the form of Bernouli Binormial, with highest probability at equal partition (N/2 at one outport and N/2 at the other). However, injection of a single photon state at the other input port can dramatically change the photon distribution at the outputs, resulting in zero probability at equal partition. Such a strong deviation from classical particle theory stems from quantum probability amplitude cancellation. The effect persists even if the N-photon state is replaced by an arbitrary state of light. A special case is the coherent state which corresponds to homodyne detection of a single photon state and can lead to the measurement of the wave function of a single photon state.

  11. Single Photon Avalanche Diodes: Towards the Large Bidimensional Arrays

    Directory of Open Access Journals (Sweden)

    Emilio Sciacca

    2008-08-01

    Full Text Available Single photon detection is one of the most challenging goals of photonics. In recent years, the study of ultra-fast and/or low-intensity phenomena has received renewed attention from the academic and industrial communities. Intense research activity has been focused on bio-imaging applications, bio-luminescence, bio-scattering methods, and, more in general, on several applications requiring high speed operation and high timing resolution. In this paper we present design and characterization of bi-dimensional arrays of a next generation of single photon avalanche diodes (SPADs. Single photon sensitivity, dark noise, afterpulsing and timing resolution of the single SPAD have been examined in several experimental conditions. Moreover, the effects arising from their integration and the readout mode have also been deeply investigated.

  12. Multi-photon absorption limits to heralded single photon sources

    Science.gov (United States)

    Husko, Chad A.; Clark, Alex S.; Collins, Matthew J.; De Rossi, Alfredo; Combrié, Sylvain; Lehoucq, Gaëlle; Rey, Isabella H.; Krauss, Thomas F.; Xiong, Chunle; Eggleton, Benjamin J.

    2013-01-01

    Single photons are of paramount importance to future quantum technologies, including quantum communication and computation. Nonlinear photonic devices using parametric processes offer a straightforward route to generating photons, however additional nonlinear processes may come into play and interfere with these sources. Here we analyse spontaneous four-wave mixing (SFWM) sources in the presence of multi-photon processes. We conduct experiments in silicon and gallium indium phosphide photonic crystal waveguides which display inherently different nonlinear absorption processes, namely two-photon (TPA) and three-photon absorption (ThPA), respectively. We develop a novel model capturing these diverse effects which is in excellent quantitative agreement with measurements of brightness, coincidence-to-accidental ratio (CAR) and second-order correlation function g(2)(0), showing that TPA imposes an intrinsic limit on heralded single photon sources. We build on these observations to devise a new metric, the quantum utility (QMU), enabling further optimisation of single photon sources. PMID:24186400

  13. CMOS-compatible photonic devices for single-photon generation

    Directory of Open Access Journals (Sweden)

    Xiong Chunle

    2016-09-01

    Full Text Available Sources of single photons are one of the key building blocks for quantum photonic technologies such as quantum secure communication and powerful quantum computing. To bring the proof-of-principle demonstration of these technologies from the laboratory to the real world, complementary metal–oxide–semiconductor (CMOS-compatible photonic chips are highly desirable for photon generation, manipulation, processing and even detection because of their compactness, scalability, robustness, and the potential for integration with electronics. In this paper, we review the development of photonic devices made from materials (e.g., silicon and processes that are compatible with CMOS fabrication facilities for the generation of single photons.

  14. Single-photon source engineering using a Modal Method

    DEFF Research Database (Denmark)

    Gregersen, Niels

    Solid-state sources of single indistinguishable photons are of great interest for quantum information applications. The semiconductor quantum dot embedded in a host material represents an attractive platform to realize such a single-photon source (SPS). A near-unity efficiency, defined as the num......Solid-state sources of single indistinguishable photons are of great interest for quantum information applications. The semiconductor quantum dot embedded in a host material represents an attractive platform to realize such a single-photon source (SPS). A near-unity efficiency, defined...

  15. Investigation of Hamamatsu H8500 phototubes as single photon detectors

    Energy Technology Data Exchange (ETDEWEB)

    Montgomery, R.A. [INFN Laboratori Nazionali di Frascati, Via Enrico Fermi, 40, 00044 Frascati (Italy); Hoek, M. [Institut für Kernphysik, Johannes Gutenberg-Universität Mainz, Johann-Joachim-Becher-Weg 45, D 55128 Mainz (Germany); Lucherini, V.; Mirazita, M.; Orlandi, A.; Anefalos Pereira, S.; Pisano, S. [INFN Laboratori Nazionali di Frascati, Via Enrico Fermi, 40, 00044 Frascati (Italy); Rossi, P. [INFN Laboratori Nazionali di Frascati, Via Enrico Fermi, 40, 00044 Frascati (Italy); Jefferson Laboratory, Thomas Jefferson National Accelerator Facility, 12000 Jefferson Avenue, Newport News, VA 23606 (United States); Viticchiè, A. [INFN Laboratori Nazionali di Frascati, Via Enrico Fermi, 40, 00044 Frascati (Italy); Witchger, A. [Department of Physics, Duquesne University, 317 Fisher Hall, Pittsburgh, PA 15282 (United States)

    2015-08-01

    We have investigated the response of a significant sample of Hamamatsu H8500 MultiAnode PhotoMultiplier Tubes (MAPMTs) as single photon detectors, in view of their use in a ring imaging Cherenkov counter for the CLAS12 spectrometer at the Thomas Jefferson National Accelerator Facility. For this, a laser working at 407.2 nm wavelength was employed. The sample is divided equally into standard window type, with a spectral response in the visible light region, and UV-enhanced window type MAPMTs. The studies confirm the suitability of these MAPMTs for single photon detection in such a Cherenkov imaging application.

  16. Graphene-Based Josephson-Junction Single-Photon Detector

    Science.gov (United States)

    Walsh, Evan D.; Efetov, Dmitri K.; Lee, Gil-Ho; Heuck, Mikkel; Crossno, Jesse; Ohki, Thomas A.; Kim, Philip; Englund, Dirk; Fong, Kin Chung

    2017-08-01

    We propose to use graphene-based Josephson junctions (GJJs) to detect single photons in a wide electromagnetic spectrum from visible to radio frequencies. Our approach takes advantage of the exceptionally low electronic heat capacity of monolayer graphene and its constricted thermal conductance to its phonon degrees of freedom. Such a system could provide high-sensitivity photon detection required for research areas including quantum information processing and radio astronomy. As an example, we present our device concepts for GJJ single-photon detectors in both the microwave and infrared regimes. The dark count rate and intrinsic quantum efficiency are computed based on parameters from a measured GJJ, demonstrating feasibility within existing technologies.

  17. New Generation of Superconducting Nanowire Single-Photon Detectors

    Directory of Open Access Journals (Sweden)

    Goltsman G.N.

    2015-01-01

    Full Text Available We present an overview of recent results for new generation of infrared and optical superconducting nanowire single-photon detectors (SNSPDs that has already demonstrated a performance that makes them devices-of-choice for many applications. SNSPDs provide high efficiency for detecting individual photons while keeping dark counts and timing jitter minimal. Besides superior detection performance over a broad optical bandwidth, SNSPDs are also compatible with an integrated optical platform as a crucial requirement for applications in emerging quantum photonic technologies. By embedding SNSPDs in nanophotonic circuits we realize waveguide integrated single photon detectors which unite all desirable detector properties in a single device.

  18. Single-photon interference experiment for high schools

    Science.gov (United States)

    Bondani, Maria

    2014-07-01

    We follow the reductio ad absurdum reasoning described in the book "Sneaking a Look at God's Cards" by Giancarlo Ghirardi to demonstrate the wave-particle duality of light in a Mach-Zehnder interferometric setup analog to the conventional Young double-slit experiment. We aim at showing the double nature of light by measuring the existence of interference fringes down to the single-photon level. The setup includes a strongly attenuated laser, polarizing beam splitters, half-waveplates, polarizers and single-photon detectors.

  19. Interferometric measurement of the helical mode of a single photon

    Energy Technology Data Exchange (ETDEWEB)

    Galvez, E J; Coyle, L E; Johnson, E; Reschovsky, B J, E-mail: egalvez@colgate.edu [Department of Physics and Astronomy, Colgate University, 13 Oak Drive, Hamilton, NY 13346 (United States)

    2011-05-15

    We present measurements of the helical mode of single photons and do so by sending heralded photons through a Mach-Zehnder interferometer that prepares the light in a helical mode with topological charge one, and interferes it with itself in the fundamental non-helical mode. Masks placed after the interferometer were used to diagnose the amplitude and phase of the mode of the light. Auxiliary measurements verified that the light was in a non-classical state. The results are in good agreement with theory. The experiments demonstrate in a direct way that single photons carry the entire spatial helical-mode information.

  20. Single photon emitters in boron nitride: More than a supplementary material

    Science.gov (United States)

    Koperski, M.; Nogajewski, K.; Potemski, M.

    2018-03-01

    We present comprehensive optical studies of recently discovered single photon sources in boron nitride, which appear in form of narrow lines emitting centres. Here, we aim to compactly characterise their basic optical properties, including the demonstration of several novel findings, in order to inspire discussion about their origin and utility. Initial inspection reveals the presence of narrow emission lines in boron nitride powder and exfoliated flakes of hexagonal boron nitride deposited on Si/SiO2 substrates. Generally rather stable, the boron nitride emitters constitute a good quality visible light source. However, as briefly discussed, certain specimens reveal a peculiar type of blinking effects, which are likely related to existence of meta-stable electronic states. More advanced characterisation of representative stable emitting centres uncovers a strong dependence of the emission intensity on the energy and polarisation of excitation. On this basis, we speculate that rather strict excitation selectivity is an important factor determining the character of the emission spectra, which allows the observation of single and well-isolated emitters. Finally, we investigate the properties of the emitting centres in varying external conditions. Quite surprisingly, it is found that the application of a magnetic field introduces no change in the emission spectra of boron nitride emitters. Further analysis of the impact of temperature on the emission spectra and the features seen in second-order correlation functions is used to provide an assessment of the potential functionality of boron nitride emitters as single photon sources capable of room temperature operation.

  1. Quantum optics. All-optical routing of single photons by a one-atom switch controlled by a single photon.

    Science.gov (United States)

    Shomroni, Itay; Rosenblum, Serge; Lovsky, Yulia; Bechler, Orel; Guendelman, Gabriel; Dayan, Barak

    2014-08-22

    The prospect of quantum networks, in which quantum information is carried by single photons in photonic circuits, has long been the driving force behind the effort to achieve all-optical routing of single photons. We realized a single-photon-activated switch capable of routing a photon from any of its two inputs to any of its two outputs. Our device is based on a single atom coupled to a fiber-coupled, chip-based microresonator. A single reflected control photon toggles the switch from high reflection (R ~ 65%) to high transmission (T ~ 90%), with an average of ~1.5 control photons per switching event (~3, including linear losses). No additional control fields are required. The control and target photons are both in-fiber and practically identical, making this scheme compatible with scalable architectures for quantum information processing. Copyright © 2014, American Association for the Advancement of Science.

  2. Combined optical and single photon emission imaging: preliminary results.

    Science.gov (United States)

    Boschi, Federico; Spinelli, Antonello E; D'Ambrosio, Daniela; Calderan, Laura; Marengo, Mario; Sbarbati, Andrea

    2009-12-07

    In vivo optical imaging instruments are generally devoted to the acquisition of light coming from fluorescence or bioluminescence processes. Recently, an instrument was conceived with radioisotopic detection capabilities (Kodak in Vivo Multispectral System F) based on the conversion of x-rays from the phosphorus screen. The goal of this work is to demonstrate that an optical imager (IVIS 200, Xenogen Corp., Alameda, USA), designed for in vivo acquisitions of small animals in bioluminescent and fluorescent modalities, can even be employed to detect signals due to radioactive tracers. Our system is based on scintillator crystals for the conversion of high-energy rays and a collimator. No hardware modifications are required. Crystals alone permit the acquisition of photons coming from an in vivo 20 g nude mouse injected with a solution of methyl diphosphonate technetium 99 metastable (Tc99m-MDP). With scintillator crystals and collimators, a set of measurements aimed to fully characterize the system resolution was carried out. More precisely, system point spread function and modulation transfer function were measured at different source depths. Results show that system resolution is always better than 1.3 mm when the source depth is less than 10 mm. The resolution of the images obtained with radioactive tracers is comparable with the resolution achievable with dedicated techniques. Moreover, it is possible to detect both optical and nuclear tracers or bi-modal tracers with only one instrument.

  3. Combined optical and single photon emission imaging: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Boschi, Federico; Calderan, Laura; Sbarbati, Andrea [Department of Morphological-Biomedical Sciences, Section of Anatomy and Histology, University of Verona, Verona (Italy); Spinelli, Antonello E [Medical Physics Department, San Raffaele Scientific Institute, Milan (Italy); D' Ambrosio, Daniela; Marengo, Mario [Medical Physics Department, S. Orsola Malpighi Hospital, Bologna (Italy)], E-mail: federico.boschi@univr.it

    2009-12-07

    In vivo optical imaging instruments are generally devoted to the acquisition of light coming from fluorescence or bioluminescence processes. Recently, an instrument was conceived with radioisotopic detection capabilities (Kodak in Vivo Multispectral System F) based on the conversion of x-rays from the phosphorus screen. The goal of this work is to demonstrate that an optical imager (IVIS 200, Xenogen Corp., Alameda, USA), designed for in vivo acquisitions of small animals in bioluminescent and fluorescent modalities, can even be employed to detect signals due to radioactive tracers. Our system is based on scintillator crystals for the conversion of high-energy rays and a collimator. No hardware modifications are required. Crystals alone permit the acquisition of photons coming from an in vivo 20 g nude mouse injected with a solution of methyl diphosphonate technetium 99 metastable (Tc99m-MDP). With scintillator crystals and collimators, a set of measurements aimed to fully characterize the system resolution was carried out. More precisely, system point spread function and modulation transfer function were measured at different source depths. Results show that system resolution is always better than 1.3 mm when the source depth is less than 10 mm. The resolution of the images obtained with radioactive tracers is comparable with the resolution achievable with dedicated techniques. Moreover, it is possible to detect both optical and nuclear tracers or bi-modal tracers with only one instrument. (letter to the editor)

  4. New cardiac cameras: single-photon emission CT and PET.

    Science.gov (United States)

    Slomka, Piotr J; Berman, Daniel S; Germano, Guido

    2014-07-01

    Nuclear cardiology instrumentation has evolved significantly in the recent years. Concerns about radiation dose and long acquisition times have propelled developments of dedicated high-efficiency cardiac SPECT scanners. Novel collimator designs, such as multipinhole or locally focusing collimators arranged in geometries that are optimized for cardiac imaging, have been implemented to enhance photon-detection sensitivity. Some of these new SPECT scanners use solid-state photon detectors instead of photomultipliers to improve image quality and to reduce the scanner footprint. These new SPECT devices allow dramatic up to 7-fold reduction in acquisition times or similar reduction in radiation dose. In addition, new hardware for photon attenuation correction allowing ultralow radiation doses has been offered by some vendors. To mitigate photon attenuation artifacts for the new SPECT scanners not equipped with attenuation correction hardware, 2-position (upright-supine or prone-supine) imaging has been proposed. PET hardware developments have been primarily driven by the requirements of oncologic imaging, but cardiac imaging can benefit from improved PET image quality and improved sensitivity of 3D systems. The time-of-flight reconstruction combined with resolution recovery techniques is now implemented by all major PET vendors. These new methods improve image contrast and image resolution and reduce image noise. High-sensitivity 3D PET without interplane septa allows reduced radiation dose for cardiac perfusion imaging. Simultaneous PET/MR hybrid system has been developed. Solid-state PET detectors with avalanche photodiodes or digital silicon photomultipliers have been introduced, and they offer improved imaging characteristics and reduced sensitivity to electromagnetic MR fields. Higher maximum count rate of the new PET detectors allows routine first-pass Rb-82 imaging, with 3D PET acquisition enabling clinical utilization of dynamic imaging with myocardial flow measurements for this tracer. The availability of high-end CT component in most PET/CT configurations enables hybrid multimodality cardiac imaging protocols with calcium scoring or CT angiography or both. Copyright © 2014. Published by Elsevier Inc.

  5. The physics of nanowire superconducting single-photon detectors

    NARCIS (Netherlands)

    Renema, Jelmer Jan

    2015-01-01

    We investigate the detection mechanism in superconducting single photon detectors via quantum detector tomography. We find that the detection event is caused by diffusion of quasiparticles from the absorption spot, combined with entrance of a vortex. Moreover, we investigate the behaviour of

  6. Purification of single-photon entanglement with linear optics

    OpenAIRE

    Sangouard, Nicolas; Simon, Christoph; Coudreau, Thomas; Gisin, Nicolas

    2008-01-01

    We show that single-photon entangled states of the form |0>|1>+|1>|0> can be purified with a simple linear-optics based protocol, which is eminently feasible with current technology. Besides its conceptual interest, this result is relevant for attractive quantum repeater protocols.

  7. An integrated single photon detector array using porous anodic alumina

    NARCIS (Netherlands)

    Melai, J.; Salm, Cora; Schmitz, Jurriaan; Smits, Sander M.; Visschers, J.L.

    2006-01-01

    Abstract—This paper outlines a single photon sensitive detector array. The detector structure is made via CMOS compatible wafer-scale post-processing. The total system comprises a CMOS imaging chip with charge sensitive pixels, an electron multiplier and a photo-cathode. The electron multiplication

  8. Extent of sensitivity of single photon production to parton distribution ...

    Indian Academy of Sciences (India)

    Extent of sensitivity of single photon production to parton distribution functions. SOMNATH DE. Variable Energy Cyclotron Centre, 1/AF Bidhan Nagar, Kolkata 700 064, India. E-mail: somvecc@gmail.com. MS received 19 September 2013; accepted 13 December 2013. DOI: 10.1007/s12043-014-0765-y; ePublication: 29 ...

  9. Simultaneous, Full Characterization of a Single-Photon State

    Directory of Open Access Journals (Sweden)

    Tim Thomay

    2017-11-01

    Full Text Available As single-photon sources become more mature and are used more often in quantum information, communications, and measurement applications, their characterization becomes more important. Single-photon-like light is often characterized by its brightness, as well as two quantum properties: the suppression of multiphoton content and the photon indistinguishability. While it is desirable to obtain these quantities from a single measurement, currently two or more measurements are required. Here, we show that using two-photon (n=2 number-resolving detectors, one can completely characterize single-photon-like states in a single measurement, where previously two or more measurements were necessary. We simultaneously determine the brightness, the suppression of multiphoton states, the indistinguishability, and the statistical distribution of Fock states to third order for a quantum light source. We find n≥3 number-resolving detectors provide no additional advantage in the single-photon characterization. The new method extracts more information per experimental trial than a conventional measurement for all input states and is particularly more efficient for statistical mixtures of photon states. Thus, using this n=2, number-resolving detector scheme will provide advantages in a variety of quantum optics measurements and systems.

  10. Deterministic Secure Quantum Communication with Collective Detection Using Single Photons

    Science.gov (United States)

    Huang, Wei; Wen, Qiao-Yan; Liu, Bin; Gao, Fei; Chen, Hui

    2012-09-01

    Two novel single-photon deterministic secure quantum communication (DSQC) schemes with collective detection are proposed. One is a two-party DSQC, the other is a DSQC network. In these two schemes, only single-photon source and single-photon measurements are required, which makes the schemes more feasible with present techniques. Apart from this, a detection strategy called collective detection is utilized in our schemes, in which the detection is taken only once after the whole process of particle transmission. Such detection strategy improves the efficiencies of our protocols and also reduces the cost of realization as the message sender only need to perform unitary operations in the whole communication. What's more, the efficiencies of qubits and source capacity are both high since almost all the states can be used to transmit message except the ones used for eavesdropping check and each single photon can carry one bit of information. Finally, we prove the security of the our protocols by using the theorems on quantum operation discrimination.

  11. Single photons, dileptons and hadrons from relativistic heavy ion ...

    Indian Academy of Sciences (India)

    Abstract. The production of single photons in Pb+Pb collisions at the CERN SPS as measured by the WA98 experiment is analysed. A quark gluon plasma is assumed to be formed initially, which expands, cools, hadronizes, and undergoes freeze-out. A rich hadronic equation of state is used and the transverse expansion of ...

  12. Single photons, dileptons and hadrons from relativistic heavy ion ...

    Indian Academy of Sciences (India)

    The production of single photons in Pb+Pb collisions at the CERN SPS as measured by the WA98 experiment is analysed. A quark gluon plasma is assumed to be formed initially, which expands, cools, hadronizes, and undergoes freeze-out. A rich hadronic equation of state is used and the transverse expansion of the ...

  13. Waveguide-Coupled Superconducting Nanowire Single-Photon Detectors

    Science.gov (United States)

    Beyer, Andrew D.; Briggs, Ryan M.; Marsili, Francesco; Cohen, Justin D.; Meenehan, Sean M.; Painter, Oskar J.; Shaw, Matthew D.

    2015-01-01

    We have demonstrated WSi-based superconducting nanowire single-photon detectors coupled to SiNx waveguides with integrated ring resonators. This photonics platform enables the implementation of robust and efficient photon-counting detectors with fine spectral resolution near 1550 nm.

  14. Deep-submicron CMOS Single Photon Detectors and Quantum Effects

    NARCIS (Netherlands)

    Karami, M.A.

    2011-01-01

    Quantum parasitic effects and miniaturization of Single Photon Avalanche Diodes in deep-submicron technologies have been studied in this thesis in detail. Tunneling noise and Random Telegraph Signal (RTS) noise have been the main two parasitic effects addressed comprehensively. While the fundamental

  15. Deterministic teleportation using single-photon entanglement as a resource

    DEFF Research Database (Denmark)

    Björk, Gunnar; Laghaout, Amine; Andersen, Ulrik L.

    2012-01-01

    We outline a proof that teleportation with a single particle is, in principle, just as reliable as with two particles. We thereby hope to dispel the skepticism surrounding single-photon entanglement as a valid resource in quantum information. A deterministic Bell-state analyzer is proposed which...

  16. ACCF/ASNC appropriateness criteria for single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI): a report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group and the American Society of Nuclear Cardiology endorsed by the American Heart Association.

    Science.gov (United States)

    Brindis, Ralph G; Douglas, Pamela S; Hendel, Robert C; Peterson, Eric D; Wolk, Michael J; Allen, Joseph M; Patel, Manesh R; Raskin, Ira E; Hendel, Robert C; Bateman, Timothy M; Cerqueira, Manuel D; Gibbons, Raymond J; Gillam, Linda D; Gillespie, John A; Hendel, Robert C; Iskandrian, Ami E; Jerome, Scott D; Krumholz, Harlan M; Messer, Joseph V; Spertus, John A; Stowers, Stephen A

    2005-10-18

    Under the auspices of the American College of Cardiology Foundation (ACCF) and the American Society of Nuclear Cardiology (ASNC), an appropriateness review was conducted for radionuclide cardiovascular imaging (RNI), specifically gated single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI). The review assessed the risks and benefits of the imaging test for several indications or clinical scenarios and scored them based on a scale of 1 to 9, where the upper range (7 to 9) implies that the test is generally acceptable and is a reasonable approach, and the lower range (1 to 3) implies that the test is generally not acceptable and is not a reasonable approach. The mid range (4 to 6) implies that the test may be generally acceptable and may be a reasonable approach for the indication. The indications for this review were primarily drawn from existing clinical practice guidelines and modified based on discussion by the ACCF Appropriateness Criteria Working Group and the Technical Panel members who rated the indications. The method for this review was based on the RAND/UCLA approach for evaluating appropriateness, which blends scientific evidence and practice experience. A modified Delphi technique was used to obtain first- and second-round ratings of 52 clinical indications. The ratings were done by a Technical Panel with diverse membership, including nuclear cardiologists, referring physicians (including an echocardiographer), health services researchers, and a payer (chief medical officer). These results are expected to have a significant impact on physician decision making and performance, reimbursement policy, and future research directions. Periodic assessment and updating of criteria will be undertaken as needed.

  17. Multiple-Event, Single-Photon Counting Imaging Sensor

    Science.gov (United States)

    Zheng, Xinyu; Cunningham, Thomas J.; Sun, Chao; Wang, Kang L.

    2011-01-01

    The single-photon counting imaging sensor is typically an array of silicon Geiger-mode avalanche photodiodes that are monolithically integrated with CMOS (complementary metal oxide semiconductor) readout, signal processing, and addressing circuits located in each pixel and the peripheral area of the chip. The major problem is its single-event method for photon count number registration. A single-event single-photon counting imaging array only allows registration of up to one photon count in each of its pixels during a frame time, i.e., the interval between two successive pixel reset operations. Since the frame time can t be too short, this will lead to very low dynamic range and make the sensor merely useful for very low flux environments. The second problem of the prior technique is a limited fill factor resulting from consumption of chip area by the monolithically integrated CMOS readout in pixels. The resulting low photon collection efficiency will substantially ruin any benefit gained from the very sensitive single-photon counting detection. The single-photon counting imaging sensor developed in this work has a novel multiple-event architecture, which allows each of its pixels to register as more than one million (or more) photon-counting events during a frame time. Because of a consequently boosted dynamic range, the imaging array of the invention is capable of performing single-photon counting under ultra-low light through high-flux environments. On the other hand, since the multiple-event architecture is implemented in a hybrid structure, back-illumination and close-to-unity fill factor can be realized, and maximized quantum efficiency can also be achieved in the detector array.

  18. Designs for high-efficiency electrically pumped photonic nanowire single-photon sources

    DEFF Research Database (Denmark)

    Gregersen, Niels; Nielsen, Torben Roland; Mørk, Jesper

    2010-01-01

    We propose and analyze three electrically-pumped nanowire single-photon source structures, which achieve output efficiencies of more than 80%. These structures are based on a quantum dot embedded in a photonic nanowire with carefully tailored ends and optimized contact electrodes. Contrary...... to conventional cavity-based sources, this non-resonant approach provides broadband spontaneous emission control and features an improved fabrication tolerance towards surface roughness and imperfections. Using an element-splitting approach, we analyze the various building blocks of the designs with respect...

  19. Interfering Heralded Single Photons from Two Separate Silicon Nanowires Pumped at Different Wavelengths

    Directory of Open Access Journals (Sweden)

    Xiang Zhang

    2016-08-01

    Full Text Available Practical quantum photonic applications require on-demand single photon sources. As one possible solution, active temporal and wavelength multiplexing has been proposed to build an on-demand single photon source. In this scheme, heralded single photons are generated from different pump wavelengths in many temporal modes. However, the indistinguishability of these heralded single photons has not yet been experimentally confirmed. In this work, we achieve 88% ± 8% Hong–Ou–Mandel quantum interference visibility from heralded single photons generated from two separate silicon nanowires pumped at different wavelengths. This demonstrates that active temporal and wavelength multiplexing could generate indistinguishable heralded single photons.

  20. Single-photon superradiance and cooperative Lamb shift in an optoelectronic device (Conference Presentation)

    Science.gov (United States)

    Sirtori, Carlo

    2017-02-01

    Superradiance is one of the many fascinating phenomena predicted by quantum electrodynamics that have first been experimentally demonstrated in atomic systems and more recently in condensed matter systems like quantum dots, superconducting q-bits, cyclotron transitions and plasma oscillations in quantum wells (QWs). It occurs when a dense collection of N identical two-level emitters are phased via the exchange of photons, giving rise to enhanced light-matter interaction, hence to a faster emission rate. Of great interest is the regime where the ensemble interacts with one photon only and therefore all of the atoms, but one, are in the ground state. In this case the quantum superposition of all possible configurations produces a symmetric state that decays radiatively with a rate N times larger than that of the individual oscillators. This phenomenon, called single photon superradiance, results from the exchange of real photons among the N emitters. Yet, to single photon superradiance is also associated another collective effect that renormalizes the emission frequency, known as cooperative Lamb shift. In this work, we show that single photon superradiance and cooperative Lamb shift can be engineered in a semiconductor device by coupling spatially separated plasma resonances arising from the collective motion of confined electrons in QWs. These resonances hold a giant dipole along the growth direction z and have no mutual Coulomb coupling. They thus behave as a collection of macro-atoms on different positions along the z axis. Our device is therefore a test bench to simulate the low excitation regime of quantum electrodynamics.

  1. Hyperbolic Metamaterial Nano-Resonators Make Poor Single Photon Sources

    CERN Document Server

    Axelrod, Simon; Wong, Herman M K; Helmy, Amr S; Hughes, Stephen

    2016-01-01

    We study the optical properties of quantum dipole emitters coupled to hyperbolic metamaterial nano-resonators using a semi-analytical quasinormal mode approach. We show that coupling to metamaterial nano-resonators can lead to significant Purcell enhancements that are nearly an order of magnitude larger than those of plasmonic resonators with comparable geometry. However, the associated single photon output $\\beta$-factors are extremely low (around 10%), far smaller than those of comparable sized metallic resonators (70%). Using a quasinormal mode expansion of the photon Green function, we describe how the low $\\beta$-factors are due to increased Ohmic quenching arising from redshifted resonances, larger quality factors and stronger confinement of light within the metal. In contrast to current wisdom, these results suggest that hyperbolic metamaterial nano-structures make poor choices for single photon sources.

  2. Protecting single-photon entanglement with practical entanglement source

    Science.gov (United States)

    Zhou, Lan; Ou-Yang, Yang; Wang, Lei; Sheng, Yu-Bo

    2017-06-01

    Single-photon entanglement (SPE) is important for quantum communication and quantum information processing. However, SPE is sensitive to photon loss. In this paper, we discuss a linear optical amplification protocol for protecting SPE. Different from the previous protocols, we exploit the practical spontaneous parametric down-conversion (SPDC) source to realize the amplification, for the ideal entanglement source is unavailable in current quantum technology. Moreover, we prove that the amplification using the entanglement generated from SPDC source as auxiliary is better than the amplification assisted with single photons. The reason is that the vacuum state from SPDC source will not affect the amplification, so that it can be eliminated automatically. This protocol may be useful in future long-distance quantum communications.

  3. Multi-group dynamic quantum secret sharing with single photons

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Hongwei [School of Science and State Key Laboratory of Information Photonics and Optical Communications, Beijing University of Posts and Telecommunications, Beijing 100876 (China); Ma, Haiqiang, E-mail: hqma@bupt.edu.cn [School of Science and State Key Laboratory of Information Photonics and Optical Communications, Beijing University of Posts and Telecommunications, Beijing 100876 (China); Wei, Kejin [School of Science and State Key Laboratory of Information Photonics and Optical Communications, Beijing University of Posts and Telecommunications, Beijing 100876 (China); Yang, Xiuqing [School of Science, Beijing Jiaotong University, Beijing 100044 (China); Qu, Wenxiu; Dou, Tianqi; Chen, Yitian; Li, Ruixue; Zhu, Wu [School of Science and State Key Laboratory of Information Photonics and Optical Communications, Beijing University of Posts and Telecommunications, Beijing 100876 (China)

    2016-07-15

    In this letter, we propose a novel scheme for the realization of single-photon dynamic quantum secret sharing between a boss and three dynamic agent groups. In our system, the boss can not only choose one of these three groups to share the secret with, but also can share two sets of independent keys with two groups without redistribution. Furthermore, the security of communication is enhanced by using a control mode. Compared with previous schemes, our scheme is more flexible and will contribute to a practical application. - Highlights: • A multi-group dynamic quantum secret sharing with single photons scheme is proposed. • Any one of the groups can be chosen to share secret through controlling the polarization of photons. • Two sets of keys can be shared simultaneously without redistribution.

  4. Microfiber coupled superconducting nanowire single-photon detectors

    Science.gov (United States)

    Xu, Yingxin; Wu, Junjie; Fang, Wei; You, Lixing; Tong, Limin

    2017-12-01

    Superconducting nanowires single-photon detectors (SNSPDs or SSPDs) have emerged as an attractive single-photon detection technology with high performance. Two types of SNSPDs have been developed so far. One is the standard-fiber-coupled SNSPD with the light normally incident on the meandered nanowires, the other is waveguide-coupled SNSPD with the nanowires fabricated on the surface of the waveguide which guides photons while the fiber is coupled to the waveguide. Here we propose a new type of SNSPD integrated with microfiber. The photons are guided by a microfiber and evanescently absorbed by the nanowire of SNSPD when the nanowire is parallel and very close to the microfiber. The numerical simulation results show that the fiber to detector coupling efficiency can be close to unity with optimized device structure/parameters. With a minimal total NbN nanowire length of about 300 μm, the absorption of the nanowire can reach 90%.

  5. Advanced time-correlated single photon counting applications

    CERN Document Server

    Becker, Wolfgang

    2015-01-01

    This book is an attempt to bridge the gap between the instrumental principles of multi-dimensional time-correlated single photon counting (TCSPC) and typical applications of the technique. Written by an originator of the technique and by sucessful users, it covers the basic principles of the technique, its interaction with optical imaging methods and its application to a wide range of experimental tasks in life sciences and clinical research. The book is recommended for all users of time-resolved detection techniques in biology, bio-chemistry, spectroscopy of live systems, live cell microscopy, clinical imaging, spectroscopy of single molecules, and other applications that require the detection of low-level light signals at single-photon sensitivity and picosecond time resolution.

  6. Superconducting Single-Photon Detectors for Integrated Quantum Optics

    OpenAIRE

    Kahl, Oliver

    2016-01-01

    This thesis reports on the implementation and characterization of a fully integrated single-photon detector. Several detector circuits are realized and it is shown that the detectors exhibit supreme detection performance over a wide optical spectrum. The detectors' scalability is showcased by the parallel operation of multiple detectors within a single integrated circuit. These demonstrations are essential for future developments in integrated quantum optics.

  7. Novel single photon sources for new generation of quantum communications

    Science.gov (United States)

    2017-06-13

    state single photon sources that was published in Nature Photonics in October 2016. 15. SUBJECT TERMS diamond color center, diamond, AOARD 16. SECURITY...06/2017 PI and Co-PI information: Igor Aharonovich, igor.aharonovich@uts.edu.au, University of Technology Sydney, School of Mathematical and...manipulation of a silicon vacancy color cent er in a nanodiamond. We demonstrate ultra fast coherent control of a photon, that make s this defect

  8. Single-photon ultrashort-lived radionuclides: symposium proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Paras, P.; Thiessen, J.W. (eds.)

    1985-01-01

    The purpose was to define the current role and state-of-the-art regarding the development, clinical applications, and usefulness of generator-produced single-photon ultrashort-lived radionuclides (SPUSLR's) and to predict their future impact on medicine. Special emphasis was placed on the generator production of iridium-191, gold-195, and krypton-81. This report contains expanded summaries of the included papers. (ACR)

  9. Nanoantenna enhancement for telecom-wavelength superconducting single photon detectors.

    Science.gov (United States)

    Heath, Robert M; Tanner, Michael G; Drysdale, Timothy D; Miki, Shigehito; Giannini, Vincenzo; Maier, Stefan A; Hadfield, Robert H

    2015-02-11

    Superconducting nanowire single photon detectors are rapidly emerging as a key infrared photon-counting technology. Two front-side-coupled silver dipole nanoantennas, simulated to have resonances at 1480 and 1525 nm, were fabricated in a two-step process. An enhancement of 50 to 130% in the system detection efficiency was observed when illuminating the antennas. This offers a pathway to increasing absorption into superconducting nanowires, creating larger active areas, and achieving more efficient detection at longer wavelengths.

  10. Advanced active quenching circuits for single-photon avalanche photodiodes

    Science.gov (United States)

    Stipčević, M.; Christensen, B. G.; Kwiat, P. G.; Gauthier, D. J.

    2016-05-01

    Commercial photon-counting modules, often based on actively quenched solid-state avalanche photodiode sensors, are used in wide variety of applications. Manufacturers characterize their detectors by specifying a small set of parameters, such as detection efficiency, dead time, dark counts rate, afterpulsing probability and single photon arrival time resolution (jitter), however they usually do not specify the conditions under which these parameters are constant or present a sufficient description. In this work, we present an in-depth analysis of the active quenching process and identify intrinsic limitations and engineering challenges. Based on that, we investigate the range of validity of the typical parameters used by two commercial detectors. We identify an additional set of imperfections that must be specified in order to sufficiently characterize the behavior of single-photon counting detectors in realistic applications. The additional imperfections include rate-dependence of the dead time, jitter, detection delay shift, and "twilighting." Also, the temporal distribution of afterpulsing and various artifacts of the electronics are important. We find that these additional non-ideal behaviors can lead to unexpected effects or strong deterioration of the system's performance. Specifically, we discuss implications of these new findings in a few applications in which single-photon detectors play a major role: the security of a quantum cryptographic protocol, the quality of single-photon-based random number generators and a few other applications. Finally, we describe an example of an optimized avalanche quenching circuit for a high-rate quantum key distribution system based on time-bin entangled photons.

  11. A search for single photon events in neutrino interactions

    Science.gov (United States)

    Kullenberg, C. T.; Mishra, S. R.; Dimmery, D.; Tian, X. C.; Autiero, D.; Gninenko, S.; Rubbia, A.; Alekhin, S.; Astier, P.; Baldisseri, A.; Baldo-Ceolin, M.; Banner, M.; Bassompierre, G.; Benslama, K.; Besson, N.; Bird, I.; Blumenfeld, B.; Bobisut, F.; Bouchez, J.; Boyd, S.; Bueno, A.; Bunyatov, S.; Camilleri, L.; Cardini, A.; Cattaneo, P. W.; Cavasinni, V.; Cervera-Villanueva, A.; Challis, R.; Chukanov, A.; Collazuol, G.; Conforto, G.; Conta, C.; Contalbrigo, M.; Cousins, R.; Degaudenzi, H.; De Santo, A.; Del Prete, T.; Di Lella, L.; do Couto e Silva, E.; Dumarchez, J.; Ellis, M.; Feldman, G. J.; Ferrari, R.; Ferrère, D.; Flaminio, V.; Fraternali, M.; Gaillard, J.-M.; Gangler, E.; Geiser, A.; Geppert, D.; Gibin, D.; Godley, A.; Gomez-Cadenas, J.-J.; Gosset, J.; Gößling, C.; Gouanère, M.; Grant, A.; Graziani, G.; Guglielmi, A.; Hagner, C.; Hernando, J.; Hurst, P.; Hyett, N.; Iacopini, E.; Joseph, C.; Juget, F.; Kent, N.; Klimov, O.; Kokkonen, J.; Kovzelev, A.; Krasnoperov, A.; Kim, J. J.; Kirsanov, M.; Kulagin, S.; Lacaprara, S.; Lachaud, C.; Lakić, B.; Lanza, A.; La Rotonda, L.; Laveder, M.; Letessier-Selvon, A.; Levy, J.-M.; Ling, J.; Linssen, L.; Ljubičić, A.; Long, J.; Lupi, A.; Lyubushkin, V.; Marchionni, A.; Martelli, F.; Méchain, X.; Mendiburu, J.-P.; Meyer, J.-P.; Mezzetto, M.; Moorhead, G. F.; Naumov, D.; Nédélec, P.; Nefedov, Yu.; Nguyen-Mau, C.; Orestano, D.; Pastore, F.; Peak, L. S.; Pennacchio, E.; Pessard, H.; Petti, R.; Placci, A.; Polesello, G.; Pollmann, D.; Polyarush, A.; Poulsen, C.; Popov, B.; Rebuffi, L.; Rico, J.; Riemann, P.; Roda, C.; Salvatore, F.; Samoylov, O.; Schahmaneche, K.; Schmidt, B.; Schmidt, T.; Sconza, A.; Scott, A. M.; Seaton, M. B.; Sevior, M.; Sillou, D.; Soler, F. J. P.; Sozzi, G.; Steele, D.; Stiegler, U.; Stipčević, M.; Stolarczyk, Th.; Tareb-Reyes, M.; Taylor, G. N.; Tereshchenko, V.; Toropin, A.; Touchard, A.-M.; Tovey, S. N.; Tran, M.-T.; Tsesmelis, E.; Ulrichs, J.; Vacavant, L.; Valdata-Nappi, M.; Valuev, V.; Vannucci, F.; Varvell, K. E.; Veltri, M.; Vercesi, V.; Vidal-Sitjes, G.; Vieira, J.-M.; Vinogradova, T.; Weber, F. V.; Weisse, T.; Wilson, F. F.; Winton, L. J.; Wu, Q.; Yabsley, B. D.; Zaccone, H.; Zuber, K.; Zuccon, P.

    2012-01-01

    We present a search for neutrino induced events containing a single, exclusive photon using data from the NOMAD experiment at the CERN SPS where the average energy of the neutrino flux is ≃ 25 GeV. The search is motivated by an excess of electron-like events in the 200-475 MeV energy region as reported by the MiniBooNE experiment. In NOMAD, photons are identified via their conversion to e+e- in an active target embedded in a magnetic field. The background to the single photon signal is dominated by the asymmetric decay of neutral pions produced either in a coherent neutrino-nucleus interaction, or in a neutrino-nucleon neutral current deep inelastic scattering, or in an interaction occurring outside the fiducial volume. All three backgrounds are determined in situ using control data samples prior to opening the 'signal-box'. In the signal region, we observe 155 events with a predicted background of 129.2 ± 8.5 ± 3.3. We interpret this as null evidence for excess of single photon events, and set a limit. Assuming that the hypothetical single photon has a momentum distribution similar to that of a photon from the coherent π0 decay, the measurement yields an upper limit on single photon events, < 4.0 ×10-4 per νμ charged current event. Narrowing the search to events where the photon is approximately collinear with the incident neutrino, we observe 78 events with a predicted background of 76.6 ± 4.9 ± 1.9 yielding a more stringent upper limit, < 1.6 ×10-4 per νμ charged current event.

  12. Single-photon nonlinear optics with graphene plasmons.

    Science.gov (United States)

    Gullans, M; Chang, D E; Koppens, F H L; García de Abajo, F J; Lukin, M D

    2013-12-13

    We show that it is possible to realize significant nonlinear optical interactions at the few photon level in graphene nanostructures. Our approach takes advantage of the electric field enhancement associated with the strong confinement of graphene plasmons and the large intrinsic nonlinearity of graphene. Such a system could provide a powerful platform for quantum nonlinear optical control of light. As an example, we consider an integrated optical device that exploits this large nonlinearity to realize a single photon switch.

  13. Single photon detection with self-quenching multiplication

    Science.gov (United States)

    Zheng, Xinyu (Inventor); Cunningham, Thomas J. (Inventor); Pain, Bedabrata (Inventor)

    2011-01-01

    A photoelectronic device and an avalanche self-quenching process for a photoelectronic device are described. The photoelectronic device comprises a nanoscale semiconductor multiplication region and a nanoscale doped semiconductor quenching structure including a depletion region and an undepletion region. The photoelectronic device can act as a single photon detector or a single carrier multiplier. The avalanche self-quenching process allows electrical field reduction in the multiplication region by movement of the multiplication carriers, thus quenching the avalanche.

  14. Single-photon imaging inspired by human vision

    Science.gov (United States)

    Mohseni, Hooman

    2008-02-01

    Single photon detectors are regarded as a key enabling technology in a wide range of medical, industrial, and military applications. However, the existing single photon detectors that can operate at or near room temperature have poor efficiency and high noise. Interestingly, the counterparts of these devices in nature, namely the rod cells, have amazingly high efficiency and low noise. In particular, the noise performance of the rod cells is five to six orders of magnitude better than the semiconductor based single photon detectors at room temperature. At Bio-inspired Sensors and Optoelectronics Laboratory, we explored the origin of such a high noise performance, and designed and implemented a novel semiconductor device based on the underlying detection mechanism in the rod cells. Our device shows very promising properties including orders of magnitude higher gain and lower noise compared with the existing devices. More interestingly, the low operating voltage of the device combined with high gain uniformity should allow, for the first time, realization of large imaging arrays with a high internal gain. Such imagers would open new opportunities for novel applications such as quantum ghost imaging.

  15. Triggered mesa-top single photon emitter arrays and on-chip integration with dielectric nanoantenna-waveguide systems

    CERN Document Server

    Zhang, Jiefei; Lu, Siyuan; Madhukar, Anupam

    2016-01-01

    Nanophotonic quantum information processing systems require spatially ordered, spectrally uniform single photon sources (SPSs), integrated on-chip with co-designed light manipulating elements providing emission rate enhancement, emitted photon guidance, and lossless propagation. Towards this objective, we introduce and report on systems comprising an SPS array with each SPS surrounded by a dielectric building block (DBB) based multifunctional light manipulation unit (LMU). For the SPS array, we report triggered single photon emission at 77K from GaAs(001)/InGaAs single quantum dots (SQDs) grown selectively on top of nanomesas using the approach of substrate-encoded size-reducing epitaxy (SESRE). Systematic temperature and power dependent photoluminescence (PL), PL excitation, time-resolved PL, and emission statistics studies reveal high spectral uniformity and single photon emission at 77.4K with $g^{(2)}$(0) of 0.24 $\\pm$ 0.07. The SESRE based SPS arrays, following growth of a planarizing overlayer, are read...

  16. Coherent single-photon absorption by single emitters coupled to 1D nanophotonic waveguides

    DEFF Research Database (Denmark)

    Chen, Yuntian; Wubs, Martijn; Mørk, Jesper

    2012-01-01

    We have derived an efficient model that allows calculating the dynamical single-photon absorption of an emitter coupled to a waveguide. We suggest a novel and simple structure that leads to strong single-photon absorption.......We have derived an efficient model that allows calculating the dynamical single-photon absorption of an emitter coupled to a waveguide. We suggest a novel and simple structure that leads to strong single-photon absorption....

  17. Third-order antibunching from an imperfect single-photon source.

    Science.gov (United States)

    Stevens, Martin J; Glancy, Scott; Nam, Sae Woo; Mirin, Richard P

    2014-02-10

    We measure second- and third-order temporal coherences, g((2))(τ) and g((3))(τ1,τ2), of an optically excited single-photon source: an InGaAs quantum dot in a microcavity pedestal. Increasing the optical excitation power leads to an increase in the measured count rate, and also an increase in multi-photon emission probability. We show that standard measurements of g((2)) provide limited information about this multi-photon probability, and that more information can be gained by simultaneously measuring g((3)). Experimental results are compared with a simple theoretical model to show that the observed antibunchings are consistent with an incoherent addition of two sources: 1) an ideal single-photon source that never emits multiple photons and 2) a background cavity emission having Poissonian photon number statistics. Spectrally resolved cross-correlation measurements between quantum-dot and cavity modes show that photons from these two sources are largely uncorrelated, further supporting the model. We also analyze the Hanbury Brown-Twiss interferometer implemented with two or three "click" detectors, and explore the conditions under which it can be used to accurately measure g((2))(τ) and g((3))(τ1,τ2).

  18. Strong single-photon coupling in superconducting quantum magnetomechanics.

    Science.gov (United States)

    Via, Guillem; Kirchmair, Gerhard; Romero-Isart, Oriol

    2015-04-10

    We show that the inductive coupling between the quantum mechanical motion of a superconducting microcantilever and a flux-dependent microwave quantum circuit can attain the strong single-photon nanomechanical coupling regime with feasible experimental parameters. We propose to use a superconducting strip, which is in the Meissner state, at the tip of a cantilever. A pickup coil collects the flux generated by the sheet currents induced by an external quadrupole magnetic field centered at the strip location. The position-dependent magnetic response of the superconducting strip, enhanced by both diamagnetism and demagnetizing effects, leads to a strong magnetomechanical coupling to quantum circuits.

  19. Room temperature mid-IR single photon spectral imaging

    DEFF Research Database (Denmark)

    Dam, Jeppe Seidelin; Tidemand-Lichtenberg, Peter; Pedersen, Christian

    2012-01-01

    modern Quantum cascade lasers have evolved as ideal coherent mid-IR excitation sources, simple, low noise, room temperature detectors and imaging systems still lag behind. We address this need presenting a novel, field-deployable, upconversion system for sensitive, 2-D, mid-IR spectral imaging. Measured...... room temperature dark noise is 0.2 photons/spatial element/second, which is a billion times below the dark noise level of cryogenically cooled InSb cameras. Single photon imaging and up to 200 x 100 spatial elements resolution is obtained reaching record high continuous wave quantum efficiency of about...

  20. Optimised quantum hacking of superconducting nanowire single-photon detectors

    Science.gov (United States)

    Tanner, Michael G.; Makarov, Vadim; Hadfield, Robert H.

    2014-03-01

    We explore bright-light control of superconducting nanowire single-photon detectors (SNSPDs) in the shunted configuration (a practical measure to avoid latching). In an experiment, we simulate an illumination pattern the SNSPD would receive in a typical quantum key distribution system under hacking attack. We show that it effectively blinds and controls the SNSPD. The transient blinding illumination lasts for a fraction of a microsecond and produces several deterministic fake clicks during this time. This attack does not lead to elevated timing jitter in the spoofed output pulse, and hence does not introduce significant errors. Five different SNSPD chip designs were tested. We consider possible countermeasures to this attack.

  1. Inhomogeneous critical current in nanowire superconducting single-photon detectors

    Energy Technology Data Exchange (ETDEWEB)

    Gaudio, R., E-mail: r.gaudio@tue.nl; Hoog, K. P. M. op ' t; Zhou, Z.; Sahin, D.; Fiore, A. [COBRA Research Institute, Eindhoven University of Technology, P.O. Box 513, NL-5600MB Eindhoven (Netherlands)

    2014-12-01

    A superconducting thin film with uniform properties is the key to realize nanowire superconducting single-photon detectors (SSPDs) with high performance and high yield. To investigate the uniformity of NbN films, we introduce and characterize simple detectors consisting of short nanowires with length ranging from 100 nm to 15 μm. Our nanowires, contrary to meander SSPDs, allow probing the homogeneity of NbN at the nanoscale. Experimental results, endorsed by a microscopic model, show the strongly inhomogeneous nature of NbN films on the sub-100 nm scale.

  2. Total teleportation of a single-photon state

    Energy Technology Data Exchange (ETDEWEB)

    Humble, Travis S [ORNL; Bennink, Ryan S [ORNL; Grice, Warren P [ORNL

    2008-01-01

    Recent demonstrations of teleportation have transferred quantum information encoded into either polarization or field-quadrature degrees of freedom (DOFs), but an outstanding question is how to simultaneously teleport quantum information encoded into multiple DOFs. We describe how the transverse-spatial, spectral and polarization states of a single photon can be simultaneously teleported using a pair of multimode, polarization-entangled photons derived from spontaneous parametric down-conversion. Furthermore, when the initial photon pair is maximally entangled in the spatial, spectral, and polarization DOFs then the photon s full quantum state can be reliably teleported using a Bell-state measurement based on sum-frequency generation.

  3. Ghosting phenomena in single photon counting imagers with Vernier anode.

    Science.gov (United States)

    Yang, Hao; Zhao, Baosheng; Qiurong, Yan; Liu, Yong'an; Hu, Huijun

    2011-02-01

    We provide the ghosting theory of two-dimensional Vernier anode based imagers. The single photon counting detection system based on Vernier anode is constructed. The ghosting, which occurs during the decoding of two-dimensional Vernier anode, and its possible solutions are described in detail. On the basis of the discussion of the decoding algorithm, the ghosting theoretical model is established. Phase conditions on which imaging ghosting can be avoided and the probability distribution function are proposed; the root causes of ghosting of two-dimensional Vernier anode are also discussed.

  4. Observation of entanglement between a quantum dot spin and a single photon.

    Science.gov (United States)

    Gao, W B; Fallahi, P; Togan, E; Miguel-Sanchez, J; Imamoglu, A

    2012-11-15

    Entanglement has a central role in fundamental tests of quantum mechanics as well as in the burgeoning field of quantum information processing. Particularly in the context of quantum networks and communication, a main challenge is the efficient generation of entanglement between stationary (spin) and propagating (photon) quantum bits. Here we report the observation of quantum entanglement between a semiconductor quantum dot spin and the colour of a propagating optical photon. The demonstration of entanglement relies on the use of fast, single-photon detection, which allows us to project the photon into a superposition of red and blue frequency components. Our results extend the previous demonstrations of single-spin/single-photon entanglement in trapped ions, neutral atoms and nitrogen-vacancy centres to the domain of artificial atoms in semiconductor nanostructures that allow for on-chip integration of electronic and photonic elements. As a result of its fast optical transitions and favourable selection rules, the scheme we implement could in principle generate nearly deterministic entangled spin-photon pairs at a rate determined ultimately by the high spontaneous emission rate. Our observation constitutes a first step towards implementation of a quantum network with nodes consisting of semiconductor spin quantum bits.

  5. Single photon image from PET with insertable collimator for boron neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Jooyoung; Suh, Tae Suk [Catholic Univ. of Korea, Seoul (Korea, Republic of); Hong, Key Jo [Stanford Univ., Stanford (United States)

    2014-05-15

    Boron neutron capture therapy (BNCT) is a radiation therapy technique for treating deep-seated brain tumors by irradiation with a thermal neutron in which boron-labelled low molecular weight compounds. Once completed, a single photon emission computed tomography (SPECT) scan is conducted to investigate for the region of therapy using an isotope exclusive to SPECT. In the case of an existing PET/SPECT combination system, at least two types of isotopes should be used for each scan with their purposes. Recently, researchers examined the effects of PET/SPECT dual modality on animal imaging systems. They reported that the PET/SPECT combination system was effective for simultaneous achievement of a single event and coincidence. The aim of our proposed system is to confirm the feasibility of extraction of two types of images from one PET module with an insertable collimator for brain tumor treatment during the BNCT. We attempted to acquire the PET and SPECT images simultaneously using only PET without an additional isotope. Single photon images were acquired using an insertable collimator on a PET detector.

  6. Doped niobium superconducting nanowire single-photon detectors

    Science.gov (United States)

    Jia, Tao; Kang, Lin; Zhang, Labao; Zhao, Qingyuan; Gu, Min; Qiu, Jian; Chen, Jian; Jin, Biaobing

    2014-09-01

    We designed and fabricated a special doped niobium (Nb*) superconducting nanowire single-photon detector (SNSPD) on MgO substrate. The superconductivity of this ultra-thin Nb* film was further improved by depositing an ultra-thin aluminum nitride protective layer on top. Compared with traditional Nb films, Nb* films present higher T C and J C. We investigated the dependence of the characteristics of devices, such as cut-off wavelength, response bandwidth, and temperature, on their geometrical dimensions. Results indicate that reduction in both the width and thickness of Nb* nanowires extended the cut-off wavelength and improved the sensitivity. The Nb* SNSPD (50 nm width and 4.5 nm thickness) exhibited single-photon sensitivities at 1,310, 1,550, and 2,010 nm. We also demonstrated an enhancement in the detection efficiency by a factor of 10 in its count rate by lowering the working temperature from 2.26 K to 315 mK.

  7. Automated Characterization of Single-Photon Avalanche Photodiode

    Directory of Open Access Journals (Sweden)

    Aina Mardhiyah M. Ghazali

    2012-01-01

    Full Text Available We report an automated characterization of a single-photon detector based on commercial silicon avalanche photodiode (PerkinElmer C30902SH. The photodiode is characterized by I-V curves at different illumination levels (darkness, 10 pW and 10 µW, dark count rate and photon detection efficiency at different bias voltages. The automated characterization routine is implemented in C++ running on a Linux computer. ABSTRAK: Kami melaporkan pencirian pengesan foton tunggal secara automatik berdasarkan kepada diod foto runtuhan silikon (silicon avalanche photodiode (PerkinElmer C30902SH komersial. Pencirian  diod foto adalah berdasarkan kepada plot arus-voltan (I-V pada tahap pencahayaan yang berbeza (kelam - tanpa cahaya, 10pW, dan 10µW, kadar bacaan latar belakang, kecekapan pengesanan foton pada voltan picuan yang berbeza. Pengaturcaraan C++ digunakan di dalam rutin pencirian automatik melalui komputer dengan sistem pengendalian LINUX.KEYWORDS: avalanche photodiode (APD; single photon detector; photon counting; experiment automation

  8. Temporal shaping of single photons enabled by entanglement

    Science.gov (United States)

    Averchenko, Valentin; Sych, Denis; Schunk, Gerhard; Vogl, Ulrich; Marquardt, Christoph; Leuchs, Gerd

    2017-10-01

    We present a method to produce pure single photons with an arbitrary designed temporal shape in a heralded way. As an indispensable resource, the method uses pairs of time-energy entangled photons. One photon of a pair undergoes temporal amplitude-phase modulation according to the desired shape. Subsequent frequency-resolved detection of the modulated photon heralds its entangled counterpart in a pure quantum state. The temporal shape of the heralded photon is indirectly affected by the modulation in the heralding arm. We derive conditions for which the shape of the heralded photon is given by the modulation function. The method can be implemented with various sources of time-energy entangled photons. In particular, using entangled photons from parametric down-conversion the method provides a simple means to generate pure shaped photons with an unprecedented broad range of temporal durations, from tenths of femtoseconds to microseconds. This shaping of single photons will push forward the implementation of scalable multidimensional quantum information protocols, efficient photon-matter coupling, and quantum control at the level of single quanta.

  9. Mitigating radiation damage of single photon detectors for space applications

    Energy Technology Data Exchange (ETDEWEB)

    Anisimova, Elena; Higgins, Brendon L.; Bourgoin, Jean-Philippe [University of Waterloo, Institute for Quantum Computing, Waterloo, ON (Canada); University of Waterloo, Department of Physics and Astronomy, Waterloo, ON (Canada); Cranmer, Miles [University of Waterloo, Institute for Quantum Computing, Waterloo, ON (Canada); Choi, Eric [University of Waterloo, Institute for Quantum Computing, Waterloo, ON (Canada); Magellan Aerospace, Ottawa, ON (Canada); Hudson, Danya; Piche, Louis P.; Scott, Alan [Honeywell Aerospace (formerly COM DEV Ltd.), Ottawa, ON (Canada); Makarov, Vadim [University of Waterloo, Institute for Quantum Computing, Waterloo, ON (Canada); University of Waterloo, Department of Physics and Astronomy, Waterloo, ON (Canada); University of Waterloo, Department of Electrical and Computer Engineering, Waterloo, ON (Canada); Jennewein, Thomas [University of Waterloo, Institute for Quantum Computing, Waterloo, ON (Canada); University of Waterloo, Department of Physics and Astronomy, Waterloo, ON (Canada); Canadian Institute for Advanced Research, Quantum Information Science Program, Toronto, ON (Canada)

    2017-12-15

    Single-photon detectors in space must retain useful performance characteristics despite being bombarded with sub-atomic particles. Mitigating the effects of this space radiation is vital to enabling new space applications which require high-fidelity single-photon detection. To this end, we conducted proton radiation tests of various models of avalanche photodiodes (APDs) and one model of photomultiplier tube potentially suitable for satellite-based quantum communications. The samples were irradiated with 106 MeV protons at doses approximately equivalent to lifetimes of 0.6, 6, 12 and 24 months in a low-Earth polar orbit. Although most detection properties were preserved, including efficiency, timing jitter and afterpulsing probability, all APD samples demonstrated significant increases in dark count rate (DCR) due to radiation-induced damage, many orders of magnitude higher than the 200 counts per second (cps) required for ground-to-satellite quantum communications. We then successfully demonstrated the mitigation of this DCR degradation through the use of deep cooling, to as low as -86 C. This achieved DCR below the required 200 cps over the 24 months orbit duration. DCR was further reduced by thermal annealing at temperatures of +50 to +100 C. (orig.)

  10. Positron Emission Tomography of the Heart

    Science.gov (United States)

    Schelbert, H. R.; Phelps, M. E.; Kuhl, D. E.

    1979-01-01

    Positron emission computed tomography (PCT) represents an important new tool for the noninvasive evaluation and, more importantly, quantification of myocardial performance. Most currently available techniques permit assessment of only one aspect of cardiac function, i.e., myocardial perfusion by gamma scintillation camera imaging with Thallium-201 or left ventricular function by echocardiography or radionuclide angiocardiography. With PCT it may become possible to study all three major segments of myocardial performance, i.e., regional blood flow, mechanical function and, most importantly, myocardial metabolism. Each of these segments can either be evaluated separately or in combination. This report briefly describes the principles and technological advantages of the imaging device, reviews currently available radioactive tracers and how they can be employed for the assessment of flow, function and metabolism; and, lastly, discusses possible applications of PCT for the study of cardiac physiology or its potential role in the diagnosis of cardiac disease.

  11. Single-photon tomographic determination of regional cerebral blood flow in epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Bonte, F.J.; Devous, M.D. Sr.; Stokely, E.M.; Homan, R.W.

    Using a single-photon emission computed tomographic scanner (SPECT) the authors determined regional cerebral blood flow (rCBF) with inhaled xenon-133, a noninvasive procedure. Studies were performed in 40 normal individuals, and these were compared with rCBF determinations in 51 patients with seizure disorders. Although positive results were obtained in 15 of 16 patients with mass lesions, the group of principal interest comprised 25 patients suffering from ''temporal lobe'' epilepsy. Only one of these had a positive x-ray computed tomogram, but 16 had positive findings on rCBF study. These findings included increased local blood flow in the ictal state and reduced flow interictally.

  12. Time correlated single-photon counting and fluorescence spectroscopy

    Science.gov (United States)

    Erdmann, Rainer; Enderlein, Jorg; Wahl, Michael

    2005-12-01

    A comprehensive reference on modern technological aspects of time-correlated single photon counting as used in academic and industrial applications. It thus covers areas that have either been neglected in the current literature, or for which an updated reference is not available. The book focuses on general fundamentals of photon statistics, light sources, and electronics for photon counting, time-correlated photon counting, data analysis, and fluorescence correlation techniques. One whole chapter is also devoted to applications of this universal technique in life sciences, with most of the attention given to fluorescence phenomena. The whole is backed by an appendix offering measurement examples and practical hints for data analysis. For physicists, spectroscopists, chemists, and biochemists.

  13. Adaptive Depth Imaging with Single-Photon Detectors

    CERN Document Server

    He, Weiji; Lin, Jie; Shen, Shanshan; Chen, Qian; Gu, Guohua; Zhou, Beibei; Zhang, Ping

    2016-01-01

    For active optical imaging, the use of single-photon detectors could greatly improve the detection sensitivity of the system. However in low light-level, traditional maximum-likelihood based imaging method needs long acquisition time to capture clear three-dimensional (3D) image. To tackle this problem, we present a novel imaging method for depth estimate, which can obtain the accurate depth image in a short acquisition time. We exploit the temporal correlations of signal and avoid building the photon-count histogram of the maximum likelihood depth estimate. Our method can efficiently distinguish signal from noise and adaptively change the dwell time of each pixel. The experiment results demonstrate that we can fast obtain the accurate depth image despite the existence of strong background noise.

  14. Advanced time-correlated single photon counting techniques

    CERN Document Server

    Becker, Wolfgang

    2005-01-01

    Time-correlated single photon counting (TCSPC) is a remarkable technique for recording low-level light signals with extremely high precision and picosecond-time resolution. TCSPC has developed from an intrinsically time-consuming and one-dimensional technique into a fast, multi-dimensional technique to record light signals. So this reference and text describes how advanced TCSPC techniques work and demonstrates their application to time-resolved laser scanning microscopy, single molecule spectroscopy, photon correlation experiments, and diffuse optical tomography of biological tissue. It gives practical hints about constructing suitable optical systems, choosing and using detectors, detector safety, preamplifiers, and using the control features and optimising the operating conditions of TCSPC devices. Advanced TCSPC Techniques is an indispensable tool for everyone in research and development who is confronted with the task of recording low-intensity light signals in the picosecond and nanosecond range.

  15. Single-photon source based on Rydberg exciton blockade

    Science.gov (United States)

    Khazali, Mohammadsadegh; Heshami, Khabat; Simon, Christoph

    2017-11-01

    Bound states of electron–hole pairs in semiconductors demonstrate a hydrogen-like behavior in their high-lying excited states that are also known as Rydberg exciton states. The strong interaction between excitons in levels with high principal quantum numbers prevents the creation of more than one exciton in a small crystal; resulting in the Rydberg blockade effect. Here, we propose a new kind of solid-state single-photon source based on the recently observed Rydberg blockade effect for excitons in cuprous oxide. Our quantitative estimates based on single and double excitation probability dynamics indicate that GHz rates and values of the second-order correlation function {g}2(0) below the percent level can be simultaneously achievable. These results should pave the way to explore applications of Rydberg excitons in photonic quantum information processing.

  16. Athermal avalanche in bilayer superconducting nanowire single-photon detectors

    Energy Technology Data Exchange (ETDEWEB)

    Verma, V. B., E-mail: verma@nist.gov; Lita, A. E.; Stevens, M. J.; Mirin, R. P.; Nam, S. W. [National Institute of Standards and Technology, 325 Broadway, Boulder, Colorado 80305 (United States)

    2016-03-28

    We demonstrate that two superconducting nanowires separated by a thin insulating barrier can undergo an avalanche process. In this process, Joule heating caused by a photodetection event in one nanowire and the associated production of athermal phonons which are transmitted through the barrier cause the transition of the adjacent nanowire from the superconducting to the normal state. We show that this process can be utilized in the fabrication of superconducting nanowire single photon detectors to improve the signal-to-noise ratio, reduce system jitter, maximize device area, and increase the external efficiency over a very broad range of wavelengths. Furthermore, the avalanche mechanism may provide a path towards a superconducting logic element based on athermal gating.

  17. Efficient quantum private comparison employing single photons and collective detection

    Science.gov (United States)

    Liu, Bin; Gao, Fei; Jia, Heng-yue; Huang, Wei; Zhang, Wei-wei; Wen, Qiao-yan

    2013-02-01

    Two efficient quantum private comparison (QPC) protocols are proposed, employing single photons and collective detection. In the proposed protocols, two distrustful parties (Alice and Bob) compare the equivalence of information with the help of a semi-honest third party (TP). Utilizing collective detection, the cost of practical realization is reduced greatly. In the first protocol, TP gains the result of the comparison. While in the second protocol, TP cannot get the comparison result. In both of our protocols, Alice and Bob only need be equipped with unitary operation machines, such as phase plates. So Alice and Bob need not to have the expensive quantum devices, such as qubit generating machine, quantum memory machine and quantum measuring machine. Security of the protocols is ensured by theorems on quantum operation discrimination.

  18. TCAD simulations for a novel single-photon avalanche diode

    Science.gov (United States)

    Jin, Xiangliang; Yang, Jia; Yang, Hongjiao; Tang, Lizhen; Liu, Weihui

    2015-03-01

    A single-photon avalanche diode (SPAD) device with P+-SEN junction, and a low concentration of N-type doping circular virtual guard-ring was presented in this paper. SEN layer of the proposed SPAD has high concentration of N-type doping, causing the SPAD low breakdown voltage (~14.26 V). What's more, an efficient and narrow (about 2μm) guard-ring of the proposed SPAD not only can withstand considerably higher electric fields for preventing edge breakdown, but also offers a little increment in fill factor compared with existing SPADs due to its small area. In addition, some Silvaco TCAD simulations have been done and verify characteristics and performance of the design in this work.

  19. A single photon resolution integrating chip for microstrip detectors

    Science.gov (United States)

    Mozzanica, A.; Bergamaschi, A.; Dinapoli, R.; Graafsma, H.; Henrich, B.; Kraft, P.; Johnson, I.; Lohmann, M.; Schmitt, B.; Shi, X.

    2011-05-01

    A charge integrating readout chip for silicon strip sensors is currently under development at Paul Sherrer Institut. The goal of the project is to provide a readout system that can sustain, through charge integration and automatic gain switching, the instantaneous many-photon deposition typical of the forthcoming XFEL machines. Nevertheless, a charge integrating readout with single photon sensitivity presents several features that can be exploited in many Synchrotron source applications: the possibility of a higher position resolution, the high photon rate capabilities and the possibility to detect low energy photon. A prototype of the readout chip (ROC) has been integrated with a strip detector and with a dedicated DAQ electronic, and it has been tested at the SYRMEP beam line (ELETTRA, Trieste). This work presents the readout chip and shows the results of the beam line tests in terms of spatial resolution and rate capabilities.

  20. Superconductor-superconductor bilayers for enhancing single-photon detection

    Science.gov (United States)

    Ivry, Yachin; Surick, Jonathan J.; Barzilay, Maya; Kim, Chung-Soo; Najafi, Faraz; Kalfon-Cohen, Estelle; Dane, Andrew D.; Berggren, Karl K.

    2017-10-01

    Here, we optimized ultrathin films of granular NbN on SiO2 and of amorphous αW5Si3. We showed that hybrid superconducting nanowire single-photon detectors (SNSPDs) made of 2 nm thick αW5Si3 films over 2 nm thick NbN films exhibit advantageous coexistence of timing (96% quantum efficiency) performance. We discuss the governing mechanism of this hybridization via the proximity effect. Our results demonstrate saturated SNSPDs performance at 1550 nm optical wavelength and suggest that such hybridization can significantly expand the range of available superconducting properties, impacting other nano-superconducting technologies. Lastly, this hybridization may be used to tune properties, such as the amorphous character of superconducting films.

  1. Superconductor-superconductor bilayers for enhancing single-photon detection.

    Science.gov (United States)

    Ivry, Yachin; Surick, Jonathan J; Barzilay, Maya; Kim, Chung-Soo; Najafi, Faraz; Kalfon-Cohen, Estelle; Dane, Andrew D; Berggren, Karl K

    2017-10-27

    Here, we optimized ultrathin films of granular NbN on SiO 2 and of amorphous αW 5 Si 3 . We showed that hybrid superconducting nanowire single-photon detectors (SNSPDs) made of 2 nm thick αW 5 Si 3 films over 2 nm thick NbN films exhibit advantageous coexistence of timing (96% quantum efficiency) performance. We discuss the governing mechanism of this hybridization via the proximity effect. Our results demonstrate saturated SNSPDs performance at 1550 nm optical wavelength and suggest that such hybridization can significantly expand the range of available superconducting properties, impacting other nano-superconducting technologies. Lastly, this hybridization may be used to tune properties, such as the amorphous character of superconducting films.

  2. Single-photon counting multicolor multiphoton fluorescence microscope.

    Science.gov (United States)

    Buehler, Christof; Kim, Ki H; Greuter, Urs; Schlumpf, Nick; So, Peter T C

    2005-01-01

    We present a multicolor multiphoton fluorescence microscope with single-photon counting sensitivity. The system integrates a standard multiphoton fluorescence microscope, an optical grating spectrograph operating in the UV-Vis wavelength region, and a 16-anode photomultiplier tube (PMT). The major technical innovation is in the development of a multichannel photon counting card (mC-PhCC) for direct signal collection from multi-anode PMTs. The electronic design of the mC-PhCC employs a high-throughput, fully-parallel, single-photon counting scheme along with a high-speed electrical or fiber-optical link interface to the data acquisition computer. There is no electronic crosstalk among the detection channels of the mC-PhCC. The collected signal remains linear up to an incident photon rate of 10(8) counts per second. The high-speed data interface offers ample bandwidth for real-time readout: 2 MByte lambda-stacks composed of 16 spectral channels, 256 x 256 pixel image with 12-bit dynamic range can be transferred at 30 frames per second. The modular design of the mC-PhCC can be readily extended to accommodate PMTs of more anodes. Data acquisition from a 64-anode PMT has been verified. As a demonstration of system performance, spectrally resolved images of fluorescent latex spheres and ex-vivo human skin are reported. The multicolor multiphoton microscope is suitable for highly sensitive, real-time, spectrally-resolved three-dimensional imaging in biomedical applications.

  3. Fast Purcell-enhanced single photon source in 1,550-nm telecom band from a resonant quantum dot-cavity coupling.

    Science.gov (United States)

    Birowosuto, Muhammad Danang; Sumikura, Hisashi; Matsuo, Shinji; Taniyama, Hideaki; van Veldhoven, Peter J; Nötzel, Richard; Notomi, Masaya

    2012-01-01

    High-bit-rate nanocavity-based single photon sources in the 1,550-nm telecom band are challenges facing the development of fibre-based long-haul quantum communication networks. Here we report a very fast single photon source in the 1,550-nm telecom band, which is achieved by a large Purcell enhancement that results from the coupling of a single InAs quantum dot and an InP photonic crystal nanocavity. At a resonance, the spontaneous emission rate was enhanced by a factor of 5 resulting a record fast emission lifetime of 0.2 ns at 1,550 nm. We also demonstrate that this emission exhibits an enhanced anti-bunching dip. This is the first realization of nanocavity-enhanced single photon emitters in the 1,550-nm telecom band. This coupled quantum dot cavity system in the telecom band thus provides a bright high-bit-rate non-classical single photon source that offers appealing novel opportunities for the development of a long-haul quantum telecommunication system via optical fibres.

  4. Heralded Single Photons Based on Spectral Multiplexing and Feed-Forward Control

    Science.gov (United States)

    Grimau Puigibert, M.; Aguilar, G. H.; Zhou, Q.; Marsili, F.; Shaw, M. D.; Verma, V. B.; Nam, S. W.; Oblak, D.; Tittel, W.

    2017-08-01

    We propose and experimentally demonstrate a novel approach to a heralded single-photon source based on spectral multiplexing (SMUX) and feed-forward-based spectral manipulation of photons created by means of spontaneous parametric down-conversion in a periodically poled LiNbO3 crystal. As a proof of principle, we show that our three-mode SMUX increases the heralded single-photon rate compared to that of the individual modes without compromising the quality of the emitted single photons. We project that by adding further modes, our approach can lead to a deterministic single-photon source.

  5. Single-photon sources for quantum technologies - Results of the joint research project SIQUTE

    DEFF Research Database (Denmark)

    Kück, S.; López, M.; Rodiek, B.

    2017-01-01

    In this presentation, the results of the joint research project “Single-Photon Sources for Quantum Technologies” (SIQUTE) [1] will be presented. The focus will be on the development of absolutely characterized single-photon sources, on the realization of an efficient waveguide-based single...

  6. Single-Photon Technologies Based on Quantum-Dots in Photonic Crystals

    DEFF Research Database (Denmark)

    Lehmann, Tau Bernstorff

    -photon purity under quasi-resonantexcitation. Furthermore the waveguide based platform demonstrates indistinguishable single-photonsat timescales up to 13 ns.A setup for active demultiplexing of single-photons to a three-fold single-photon state is proposed.Using a fast electro-optical modulator, single...

  7. Control of single photon emitters in semiconductor nanowires by surface acoustic waves

    Science.gov (United States)

    Lazić, S.; Hernández-Mínguez, A.; Santos, P. V.

    2017-08-01

    We report on an experimental study into the effects of surface acoustic waves on the optical emission of dot-in-a-nanowire heterostructures in III-V material systems. Under direct optical excitation, the excitonic energy levels in III-nitride dot-in-a-nanowire heterostructures oscillate at the acoustic frequency, producing a characteristic splitting of the emission lines in the time-integrated photoluminescence spectra. This acoustically induced periodic tuning of the excitonic transition energies is combined with spectral detection filtering and employed as a tool to regulate the temporal output of anti-bunched photons emitted from these nanowire quantum dots. In addition, the acoustic transport of electrons and holes along a III-arsenide nanowire injects the electric charges into an ensemble of quantum dot-like recombination centers that are spatially separated from the optical excitation area. The acoustic population and depopulation mechanism determines the number of carrier recombination events taking place simultaneously in the ensemble, thus allowing control of the anti-bunching degree of the emitted photons. The results presented are relevant for the dynamic control of single photon emission in III-V semiconductor heterostructures.

  8. Lecture demonstrations of interference and quantum erasing with single photons

    Science.gov (United States)

    Dimitrova, T. L.; Weis, A.

    2009-07-01

    Single-photon interference is a beautiful manifestation of the wave-particle duality of light and the double-slit Gedankenexperiment is a standard lecture example for introducing quantum mechanical reality. Interference arises only if each photon can follow several (classical) paths from the source to the detector, and if one does not have the possibility to determine which specific path the photon has taken. Attaching a specific label to the photon traveling along a specific path destroys the interference. However, in some cases those labels can be erased from the photon between leaving the apparatus and being detected, by which interference can be restored, a phenomenon called quantum erasing. We present lecture demonstration experiments that illustrate the wave-particle duality of light and the phenomenon of quantum erasing. Both experiments are first shown with strong light and, in a second step, on a photon-by-photon basis. The smooth transition from the quantum to the classical case can be shown in real time by varying the incident light intensity.

  9. Tracking hidden objects with a single-photon camera

    CERN Document Server

    Gariepy, Genevieve; Henderson, Robert; Leach, Jonathan; Faccio, Daniele

    2015-01-01

    The ability to know what is hidden around a corner or behind a wall provides a crucial advantage when physically going around the obstacle is impossible or dangerous. Previous solutions to this challenge were constrained e.g. by their physical size, the requirement of reflective surfaces or long data acquisition times. These impede both the deployment of the technology outside the laboratory and the development of significant advances, such as tracking the movement of large-scale hidden objects. We demonstrate a non-line-of-sight laser ranging technology that relies upon the ability, using only a floor surface, to send and detect light that is scattered around an obstacle. A single-photon avalanche diode (SPAD) camera detects light back-scattered from a hidden object that can then be located with centimetre precision, simultaneously tracking its movement. This non-line-of-sight laser ranging system is also shown to work at human length scales, paving the way for a variety of real-life situations.

  10. A Search for Single Photon Events in Neutrino Interactions

    CERN Document Server

    Kullenberg, C.T.; Dimmery, D.; Tian, X.C.; Autiero, D.; Gninenko, S.; Rubbia, A.; Alekhin, S.; Astier, P.; Baldisseri, A.; Baldo-Ceolin, M.; Banner, M.; Bassompierre, G.; Benslama, K.; Besson, N.; Bird, I.; Blumenfeld, B.; Bobisut, F.; Bouchez, J.; Boyd, S.; Bueno, A.; Bunyatov, S.; Camilleri, L.; Cardini, A.; Cattaneo, P.W.; Cavasinni, V.; Cervera-Villanueva, A.; Challis, R.; Chukanov, A.; Collazuol, G.; Conforto, G.; Conta, C.; Contalbrigo, M.; Cousins, R.; Degaudenzi, H.; De Santo, A.; Del Prete, T.; Di Lella, L.; do Couto e Silva, E.; Dumarchez, J.; Ellis, M.; Feldman, G.J.; Ferrari, R.; Ferrère, D.; Flaminio, V.; Fraternali, M.; Gaillard, J.-M.; Gangler, E.; Geiser, A.; Geppert, D.; Gibin, D.; Godley, A.; Gomez-Cadenas, J.-J.; Gosset, J.; Gößling, C.; Gouanère, M.; Grant, A.; Graziani, G.; Guglielmi, A.; Hagner, C.; Hernando, J.; Hurst, P.; Hyett, N.; Iacopini, E.; Joseph, C.; Juget, F.; Kent, N.; Klimov, O.; Kokkonen, J.; Kovzelev, A.; Krasnoperov, A.; Kim, J.J.; Kirsanov, M.; Kulagin, S.; Lacaprara, S.; Lachaud, C.; Lakić, B.; Lanza, A.; La Rotonda, L.; Laveder, M.; Letessier-Selvon, A.; Levy, J.M.; Ling, J.; Linssen, L.; Ljubičic, A.; Long, J.; Lupi, A.; Lyubushkin, V.; Marchionni, A.; Martelli, F.; Méchain, X.; Mendiburu, J.-P.; Meyer, J.-P.; Mezzetto, M.; Moorhead, G.F.; Naumov, D.; Nédélec, P.; Nefedov, Yu.; Nguyen-Mau, C.; Orestano, D.; Pastore, F.; Peak, L.S.; Pennacchio, E.; Pessard, H.; Petti, R.; Placci, A.; Polesello, G.; Pollmann, D.; Polyarush, A.; Poulsen, C.; Popov, B.; Rebuffi, L.; Rico, J.; Riemann, P.; Roda, C.; Salvatore, F.; Samoylov, O.; Schahmaneche, K.; Schmidt, B.; Schmidt, T.; Sconza, A.; Scott, A.M.; Seaton, M.B.; Sevior, M.; Sillou, D.; Soler, F.J.P.; Sozzi, G.; Steele, D.; Stiegler, U.; Stipčević, M.; Stolarczyk, Th.; Tareb-Reyes, M.; Taylor, G.N.; Tereshchenko, V.; Toropin, A.; Touchard, A.-M.; Tovey, S.N.; Tran, M.-T.; Tsesmelis, E.; Ulrichs, J.; Vacavant, L.; Valdata-Nappi, M.; Valuev, V.; Vannucci, F.; Varvell, K.E.; Veltri, M.; Vercesi, V.; Vidal-Sitjes, G.; Vieira, J.-M.; Vinogradova, T.; Weber, F.V.; Weisse, T.; Wilson, F.F.; Winton, L.J.; Wu, Q.; Yabsley, B.D.; Zaccone, H.; Zuber, K.; Zuccon, P.

    2012-01-01

    We present a search for neutrino-induced events containing a single, exclusive photon using data from the NOMAD experiment at the CERN SPS where the average energy of the neutrino flux is $\\simeq 25$ GeV. The search is motivated by an excess of electron-like events in the 200--475 MeV energy region as reported by the MiniBOONE experiment. In NOMAD, photons are identified via their conversion to $e^+e^-$ in an active target embedded in a magnetic field. The background to the single photon signal is dominated by the asymmetric decay of neutral pions produced either in a coherent neutrino-nucleus interaction, or in a neutrino-nucleon neutral current deep inelastic scattering, or in an interaction occurring outside the fiducial volume. All three backgrounds are determined {\\it in situ} using control data samples prior to opening the `signal-box'. In the signal region, we observe {\\bf 155} events with a predicted background of {\\bf 129.2 $\\pm$ 8.5 $\\pm$ 3.3}. We interpret this as null evidence for excess of single...

  11. Proposal for automated transformations on single-photon multipath qudits

    Science.gov (United States)

    Baldijão, R. D.; Borges, G. F.; Marques, B.; Solís-Prosser, M. A.; Neves, L.; Pádua, S.

    2017-09-01

    We propose a method for implementing automated state transformations on single-photon multipath qudits encoded in a one-dimensional transverse spatial domain. It relies on transferring the encoding from this domain to the orthogonal one by applying a spatial phase modulation with diffraction gratings, merging all the initial propagation paths by using a stable interferometric network, and filtering out the unwanted diffraction orders. The automation feature is attained by utilizing a programmable phase-only spatial light modulator (SLM) where properly designed diffraction gratings displayed on its screen will implement the desired transformations, including, among others, projections, permutations, and random operations. We discuss the losses in the process which is, in general, inherently nonunitary. Some examples of transformations are presented and, considering a realistic scenario, we analyze how they will be affected by the pixelated structure of the SLM screen. The method proposed here enables one to implement much more general transformations on multipath qudits than is possible with a SLM alone operating in the diagonal basis of which-path states. Therefore, it will extend the range of applicability for this encoding in high-dimensional quantum information and computing protocols as well as fundamental studies in quantum theory.

  12. Single-photon scattering with counter rotating wave interaction

    Science.gov (United States)

    He, Qi-Kai; Zhu, Wei; Wang, Z. H.; Zhou, D. L.

    2017-07-01

    Recent experiments have pushed the studies on atom-photon interactions to the ultrastrong regime, which motivates the exploration of physics beyond the rotation wave approximation. Here we study the single-photon scattering on a system composed of a coupling cavity array with a two-level atom in the center cavity, which, by varying two outside coupling parameters, corresponds to a model from a supercavity (SC) QED to a waveguide QED with counter rotating wave (CRW) interaction. By applying a time-independent scattering theory based on the bound states in the scattering region, we find that the CRW interaction obviously changes the transmission valley even in the weak atom-cavity coupling regime; in particular, the CRW interaction leads to an inelastic scattering process and a Fano-type resonance, which is directly observed in the crossover from the SC-QED case to the waveguide QED case. Predictably, our findings provide the potential of manipulating the CRW effects in realistic systems and pave the way for the numerical study of very general QED systems.

  13. Photoreactions of Porphyrins Initiated by Deep Ultraviolet Single Photons.

    Science.gov (United States)

    Chen, Jing; Luo, Zhixun; Fu, Hongbing; Yao, Jiannian

    2017-06-22

    The newly built 177 nm all-solid-state deep ultraviolet (DUV) laser photoionization mass spectrometer finds a unique advantage to identify porphyrins that bear ionization energies close to 7.0 eV. We observed dramatic selectivity of tetraphenylporphyrins (TPPs) pertaining to varied photochemical processes initiated by the DUV laser excitation. Single-photon ionization was found dominant for 2H-TPP resulting in a fragmentation-free mass spectrum; photoinduced dehydrogenation was observed for zinc TPP, but both dehydrogenation and demetalation are noted for copper TPP. Along with first-principle calculations, we demonstrate how the photoinduced reactions vary with residual energies of photoionization, highest occupied molecular orbital-lowest unoccupied molecular orbital gaps, donor-acceptor orbital overlaps, single-step barriers, and whether or not there is a major process of structural rearrangement. It is demonstrated that the rotation of benzene ring under proper laser radiation prompts dehydrogenation process; also, metallo-TPPs do not support direct demetalation, but it is selectively accomplishable along with dehydrogenation and successive hydrogenation processes. These findings not only provide insights into the hydrogen atom transfer in porphyrins initiated by ultraviolet laser but also suggest promising applications of the DUV laser in designed synthesis and chemical modification of porphyrins.

  14. Room temperature mid-IR single photon spectral imaging

    CERN Document Server

    Dam, Jeppe Seidelin; Tidemand-Lichtenberg, Peter

    2012-01-01

    Spectral imaging and detection of mid-infrared (mid-IR) wavelengths are emerging as an enabling technology of great technical and scientific interest; primarily because important chemical compounds display unique and strong mid-IR spectral fingerprints revealing valuable chemical information. While modern Quantum cascade lasers have evolved as ideal coherent mid-IR excitation sources, simple, low noise, room temperature detectors and imaging systems still lag behind. We address this need presenting a novel, field-deployable, upconversion system for sensitive, 2-D, mid-IR spectral imaging. Measured room temperature dark noise is 0.2 photons/spatial element/second, which is a billion times below the dark noise level of cryogenically cooled InSb cameras. Single photon imaging and up to 200 x 100 spatial elements resolution is obtained reaching record high continuous wave quantum efficiency of about 20 % for polarized incoherent light at 3 \\mum. The proposed method is relevant for existing and new mid-IR applicat...

  15. Photon correlation in single-photon frequency upconversion.

    Science.gov (United States)

    Gu, Xiaorong; Huang, Kun; Pan, Haifeng; Wu, E; Zeng, Heping

    2012-01-30

    We experimentally investigated the intensity cross-correlation between the upconverted photons and the unconverted photons in the single-photon frequency upconversion process with multi-longitudinal mode pump and signal sources. In theoretical analysis, with this multi-longitudinal mode of both signal and pump sources system, the properties of the signal photons could also be maintained as in the single-mode frequency upconversion system. Experimentally, based on the conversion efficiency of 80.5%, the joint probability of simultaneously detecting at upconverted and unconverted photons showed an anti-correlation as a function of conversion efficiency which indicated the upconverted photons were one-to-one from the signal photons. While due to the coherent state of the signal photons, the intensity cross-correlation function g(2)(0) was shown to be equal to unity at any conversion efficiency, agreeing with the theoretical prediction. This study will benefit the high-speed wavelength-tunable quantum state translation or photonic quantum interface together with the mature frequency tuning or longitudinal mode selection techniques.

  16. Direct fiber-coupled single photon source based on a photonic crystal waveguide

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Byeong-Hyeon, E-mail: seygene@kaist.ac.kr; Lee, Chang-Min; Lim, Hee-Jin [Department of Physics, KAIST, Daejeon 305-701 (Korea, Republic of); Schlereth, Thomas W.; Kamp, Martin [Technische Physik, Physikalisches Institut and Wilhelm Conrad Röntgen-Center for Complex Material Systems, Universität Würzburg, Am Hubland, D-97074 Würzburg (Germany); Höfling, Sven [Technische Physik, Physikalisches Institut and Wilhelm Conrad Röntgen-Center for Complex Material Systems, Universität Würzburg, Am Hubland, D-97074 Würzburg (Germany); SUPA, School of Physics and Astronomy, University of St. Andrews, St. Andrews KY16 9SS (United Kingdom); Lee, Yong-Hee [Department of Physics, KAIST, Daejeon 305-701 (Korea, Republic of); Graduate School of Nanoscience and Technology (WCU), KAIST, Daejeon 305-701 (Korea, Republic of)

    2015-08-24

    A single photon source plays a key role in quantum applications such as quantum computers and quantum communications. Epitaxially grown quantum dots are one of the promising platforms to implement a good single photon source. However, it is challenging to realize an efficient single photon source based on semiconductor materials due to their high refractive index. Here we demonstrate a direct fiber coupled single photon source with high collection efficiency by employing a photonic crystal (PhC) waveguide and a tapered micro-fiber. To confirm the single photon nature, the second-order correlation function g{sup (2)}(τ) is measured with a Hanbury Brown-Twiss setup. The measured g{sup (2)}(0) value is 0.15, and we can estimate 24% direct collection efficiency from a quantum dot to the fiber.

  17. Tomography of a Mode-Tunable Coherent Single-Photon Subtractor

    Directory of Open Access Journals (Sweden)

    Young-Sik Ra

    2017-07-01

    Full Text Available Single-photon subtraction plays important roles in optical quantum information processing as it provides a non-Gaussian characteristic in continuous-variable quantum information. While the conventional way of implementing single-photon subtraction based on a low-reflectance beam splitter works properly for a single-mode quantum state, it is unsuitable for a multimode quantum state because a single photon is subtracted from all multiple modes without maintaining their mode coherence. Here, we experimentally implement and characterize a mode-tunable coherent single-photon subtractor based on sum-frequency generation. It can subtract a single photon exclusively from one desired time-frequency mode of light or from a coherent superposition of multiple time-frequency modes. To experimentally characterize the time-frequency modes of the single-photon subtractor, we employ quantum process tomography based on coherent states. The mode-tunable coherent single-photon subtractor will be an essential element for realizing non-Gaussian quantum networks necessary to get a quantum advantage in information processing.

  18. EQUIPMENTS TO SINGLE PHOTON REGISTRATION. PART 1. FEATURES AND POSSIBILITIES OF MULTI-CHANNEL PHOTODETECTORS WITH INTRINSIC AMPLIFICATION. (REVIEW

    Directory of Open Access Journals (Sweden)

    O. V. Dvornikov

    2012-01-01

    Full Text Available The main types of the modern photo detectors applied to single photon registration are analyzed. It is offered to use silicon photomultipliers for production of multi-channel optoelectronic systems with the single photon resolution.

  19. Low-noise low-jitter 32-pixels CMOS single-photon avalanche diodes array for single-photon counting from 300 nm to 900 nm

    Energy Technology Data Exchange (ETDEWEB)

    Scarcella, Carmelo; Tosi, Alberto, E-mail: alberto.tosi@polimi.it; Villa, Federica; Tisa, Simone; Zappa, Franco [Politecnico di Milano, Dipartimento di Elettronica, Informazione e Bioingegneria, Piazza Leonardo da Vinci 32, I-20133 Milano (Italy)

    2013-12-15

    We developed a single-photon counting multichannel detection system, based on a monolithic linear array of 32 CMOS SPADs (Complementary Metal-Oxide-Semiconductor Single-Photon Avalanche Diodes). All channels achieve a timing resolution of 100 ps (full-width at half maximum) and a photon detection efficiency of 50% at 400 nm. Dark count rate is very low even at room temperature, being about 125 counts/s for 50 μm active area diameter SPADs. Detection performance and microelectronic compactness of this CMOS SPAD array make it the best candidate for ultra-compact time-resolved spectrometers with single-photon sensitivity from 300 nm to 900 nm.

  20. Efficient single-photon frequency conversion in the microwave domain using superconducting quantum circuits

    Science.gov (United States)

    Jia, W. Z.; Wang, Y. W.; Liu, Yu-xi

    2017-11-01

    We present an approach to achieve efficient single-photon frequency conversion in the microwave domain based on coherent control in superconducting quantum circuits, which consist of a driven artificial atom coupled to a semi-infinite transmission line. Using the full quantum-mechanical method, we analyze the single-photon scattering process in this system and find that single-photon frequency up- or down-conversion with efficiency close to unity can be achieved by adjusting the parameters of the control field applied to the artificial atom. We further show that our approach is experimentally feasible in currently available superconducting flux qubit circuits.

  1. Validation of the Gate simulation platform in single photon emission computed tomography and application to the development of a complete 3-dimensional reconstruction algorithm; Validation de la plate-forme de simulation GATE en tomographie a emission monophotonique et application au developpement d'un algorithme de reconstruction 3D complete

    Energy Technology Data Exchange (ETDEWEB)

    Lazaro, D

    2003-10-01

    Monte Carlo simulations are currently considered in nuclear medical imaging as a powerful tool to design and optimize detection systems, and also to assess reconstruction algorithms and correction methods for degrading physical effects. Among the many simulators available, none of them is considered as a standard in nuclear medical imaging: this fact has motivated the development of a new generic Monte Carlo simulation platform (GATE), based on GEANT4 and dedicated to SPECT/PET (single photo emission computed tomography / positron emission tomography) applications. We participated during this thesis to the development of the GATE platform within an international collaboration. GATE was validated in SPECT by modeling two gamma cameras characterized by a different geometry, one dedicated to small animal imaging and the other used in a clinical context (Philips AXIS), and by comparing the results obtained with GATE simulations with experimental data. The simulation results reproduce accurately the measured performances of both gamma cameras. The GATE platform was then used to develop a new 3-dimensional reconstruction method: F3DMC (fully 3-dimension Monte-Carlo) which consists in computing with Monte Carlo simulation the transition matrix used in an iterative reconstruction algorithm (in this case, ML-EM), including within the transition matrix the main physical effects degrading the image formation process. The results obtained with the F3DMC method were compared to the results obtained with three other more conventional methods (FBP, MLEM, MLEMC) for different phantoms. The results of this study show that F3DMC allows to improve the reconstruction efficiency, the spatial resolution and the signal to noise ratio with a satisfactory quantification of the images. These results should be confirmed by performing clinical experiments and open the door to a unified reconstruction method, which could be applied in SPECT but also in PET. (author)

  2. NFAD Arrays for Single Photon Optical Communications at 1.5 um Project

    Data.gov (United States)

    National Aeronautics and Space Administration — For this program, we propose to develop large pixel-count single photon counting detector arrays suitable for deployment in spacecraft terminal receivers supporting...

  3. Storing single photons emitted by a quantum memory on a highly excited Rydberg state.

    Science.gov (United States)

    Distante, Emanuele; Farrera, Pau; Padrón-Brito, Auxiliadora; Paredes-Barato, David; Heinze, Georg; de Riedmatten, Hugues

    2017-01-19

    Strong interaction between two single photons is a long standing and important goal in quantum photonics. This would enable a new regime of nonlinear optics and unlock several applications in quantum information science, including photonic quantum gates and deterministic Bell-state measurements. In the context of quantum networks, it would be important to achieve interactions between single photons from independent photon pairs storable in quantum memories. So far, most experiments showing nonlinearities at the single-photon level have used weak classical input light. Here we demonstrate the storage and retrieval of a paired single photon emitted by an ensemble quantum memory in a strongly nonlinear medium based on highly excited Rydberg atoms. We show that nonclassical correlations between the two photons persist after retrieval from the Rydberg ensemble. Our result is an important step towards deterministic photon-photon interactions, and may enable deterministic Bell-state measurements with multimode quantum memories.

  4. Efficiency and Coherence of Quantum-Dot Single-Photon Sources

    DEFF Research Database (Denmark)

    Madsen, Marta Arcari

    in a Hong-Ou-Mandel experiment. Finally, we demonstrate that a coherent quantum dot coupled to a photonic crystal waveguide is not only a promising single-photon source, but also a highly nonlinear system sensitive at the single-photon level. By performing resonant transmission measurements through...... on this result, we improved the design of the photonic crystal waveguide, and we characterized in detail the efficiency of the device and the coherence of the emitted single photons. We investigate the decoherence mechanisms affecting the quantum dots by performing resonance fluorescence experiments on emitters...... of a single charge. A very high degree of coherence can be achieved by embedding quantum dots in electrically gated samples. We show that a single quantum dot behaves like a nearly-ideal two-level system in a sample with electrical gates, and single photons emitted up to 1 μs apart show indistinguishability...

  5. Efficient Concentration Protocols for the Single-Photon Entanglement State with Polarization Feature

    Directory of Open Access Journals (Sweden)

    Lan Zhou

    2017-03-01

    Full Text Available We propose two efficient entanglement concentration protocols (ECPs for arbitrary less-entangled single-photon entanglement state, in which the photon qubit has the polarization feature. The first ECP is in linear optics, and the second ECP is in nonlinear optics. The two ECPs have some attractive advantages. First, they can preserve the polarization feature of the photon qubit, while all the other existing ECPs for single photon state cannot achieve this goal. Second, they only require one pair of less-entangled single-photon entanglement state and some auxiliary single photons. Third, they only require local operations. Especially, the second ECP can be used repeatedly, which can increase its success probability largely. Based on above properties, our two ECPs, especially the second one may be useful in current and future quantum communication.

  6. Single Photon Sensitive HgCdTe Avalanche Photodiode Detector (APD) Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Leveraging Phase I SBIR successes, in Phase II, a single photon sensitive LIDAR receiver will be fabricated and delivered to NASA. In Phase I, high-gain,...

  7. Experimental single photon exchange along a space link of 7000 km

    DEFF Research Database (Denmark)

    Dequal, Daniele; Vallone, Giuseppe; Bacco, Davide

    2015-01-01

    Extending the single photon transmission distance is a basic requirement for the implementation of quantum communication on a global scale. In this work we report the single photon exchange from a medium Earth orbit satellite (MEO) at more than 7000 km of slanted distance to the ground station...... at the Matera Laser Ranging Observatory. The single photon transmitter was realized by exploiting the corner cube retro-reflectors mounted on the LAGEOS-2 satellite. Long duration of data collection is possible with such altitude, up to 43 minutes in a single passage. The mean number of photons per pulse (µsat......) has been limited to 1 for 200 seconds, resulting in an average detection rate of 3.0 cps and a signal to noise ratio of 1.5. The feasibility of single photon exchange from MEO satellites paves the way to tests of Quantum Mechanics in moving frames and to global Quantum Information....

  8. Complementarity in single photon interference – the role of the mode function and vacuum fields

    National Research Council Canada - National Science Library

    Menzel, R; Puhlmann, D; Heuer, A

    2017-01-01

    ...).Single photon first order interferences of spatially separated regions from the cone structure of spontaneous parametric down conversion allow for analyzing the role of the mode function in quantum...

  9. Fast path and polarization manipulation of telecom wavelength single photons in lithium niobate waveguide devices.

    Science.gov (United States)

    Bonneau, Damien; Lobino, Mirko; Jiang, Pisu; Natarajan, Chandra M; Tanner, Michael G; Hadfield, Robert H; Dorenbos, Sanders N; Zwiller, Val; Thompson, Mark G; O'Brien, Jeremy L

    2012-02-03

    We demonstrate fast polarization and path control of photons at 1550 nm in lithium niobate waveguide devices using the electro-optic effect. We show heralded single photon state engineering, quantum interference, fast state preparation of two entangled photons, and feedback control of quantum interference. These results point the way to a single platform that will enable the integration of nonlinear single photon sources and fast reconfigurable circuits for future photonic quantum information science and technology.

  10. Integration of Single-Photon Sources and Detectors on GaAs

    Directory of Open Access Journals (Sweden)

    Giulia Enrica Digeronimo

    2016-10-01

    Full Text Available Quantum photonic integrated circuits (QPICs on a GaAs platform allow the generation, manipulation, routing, and detection of non-classical states of light, which could pave the way for quantum information processing based on photons. In this article, the prototype of a multi-functional QPIC is presented together with our recent achievements in terms of nanofabrication and integration of each component of the circuit. Photons are generated by excited InAs quantum dots (QDs and routed through ridge waveguides towards photonic crystal cavities acting as filters. The filters with a transmission of 20% and free spectral range ≥66 nm are able to select a single excitonic line out of the complex emission spectra of the QDs. The QD luminescence can be measured by on-chip superconducting single photon detectors made of niobium nitride (NbN nanowires patterned on top of a suspended nanobeam, reaching a device quantum efficiency up to 28%. Moreover, two electrically independent detectors are integrated on top of the same nanobeam, resulting in a very compact autocorrelator for on-chip g(2(τ measurements.

  11. Temporal Purity and Quantum Interference of Single Photons from Two Independent Cold Atomic Ensembles.

    Science.gov (United States)

    Qian, Peng; Gu, Zhenjie; Cao, Rong; Wen, Rong; Ou, Z Y; Chen, J F; Zhang, Weiping

    2016-07-01

    The temporal purity of single photons is crucial to the indistinguishability of independent photon sources for the fundamental study of the quantum nature of light and the development of photonic technologies. Currently, the technique for single photons heralded from time-frequency entangled biphotons created in nonlinear crystals does not guarantee the temporal-quantum purity, except using spectral filtering. Nevertheless, an entirely different situation is anticipated for narrow-band biphotons with a coherence time far longer than the time resolution of a single-photon detector. Here we demonstrate temporally pure single photons with a coherence time of 100 ns, directly heralded from the time-frequency entangled biphotons generated by spontaneous four-wave mixing in cold atomic ensembles, without any supplemented filters or cavities. A near-perfect purity and indistinguishability are both verified through Hong-Ou-Mandel quantum interference using single photons from two independent cold atomic ensembles. The time-frequency entanglement provides a route to manipulate the pure temporal state of the single-photon source.

  12. Investigating and improving student understanding of quantum mechanics in the context of single photon interference

    Directory of Open Access Journals (Sweden)

    Emily Marshman

    2017-04-01

    Full Text Available Single photon experiments involving a Mach-Zehnder interferometer can illustrate the fundamental principles of quantum mechanics, e.g., the wave-particle duality of a single photon, single photon interference, and the probabilistic nature of quantum measurement involving single photons. These experiments explicitly make the connection between the abstract quantum theory and concrete laboratory settings and have the potential to help students develop a solid grasp of the foundational issues in quantum mechanics. Here we describe students’ conceptual difficulties with these topics in the context of Mach-Zehnder interferometer experiments with single photons and how the difficulties found in written surveys and individual interviews were used as a guide in the development of a Quantum Interactive Learning Tutorial (QuILT. The QuILT uses an inquiry-based approach to learning and takes into account the conceptual difficulties found via research to help upper-level undergraduate and graduate students learn about foundational quantum mechanics concepts using the concrete quantum optics context. It strives to help students learn the basics of quantum mechanics in the context of single photon experiment, develop the ability to apply fundamental quantum principles to experimental situations in quantum optics, and explore the differences between classical and quantum ideas in a concrete context. We discuss the findings from in-class evaluations suggesting that the QuILT was effective in helping students learn these abstract concepts.

  13. Investigating and improving student understanding of quantum mechanics in the context of single photon interference

    Science.gov (United States)

    Marshman, Emily; Singh, Chandralekha

    2017-06-01

    Single photon experiments involving a Mach-Zehnder interferometer can illustrate the fundamental principles of quantum mechanics, e.g., the wave-particle duality of a single photon, single photon interference, and the probabilistic nature of quantum measurement involving single photons. These experiments explicitly make the connection between the abstract quantum theory and concrete laboratory settings and have the potential to help students develop a solid grasp of the foundational issues in quantum mechanics. Here we describe students' conceptual difficulties with these topics in the context of Mach-Zehnder interferometer experiments with single photons and how the difficulties found in written surveys and individual interviews were used as a guide in the development of a Quantum Interactive Learning Tutorial (QuILT). The QuILT uses an inquiry-based approach to learning and takes into account the conceptual difficulties found via research to help upper-level undergraduate and graduate students learn about foundational quantum mechanics concepts using the concrete quantum optics context. It strives to help students learn the basics of quantum mechanics in the context of single photon experiment, develop the ability to apply fundamental quantum principles to experimental situations in quantum optics, and explore the differences between classical and quantum ideas in a concrete context. We discuss the findings from in-class evaluations suggesting that the QuILT was effective in helping students learn these abstract concepts.

  14. Reducing Phonon-Induced Decoherence in Solid-State Single-Photon Sources with Cavity Quantum Electrodynamics.

    Science.gov (United States)

    Grange, T; Somaschi, N; Antón, C; De Santis, L; Coppola, G; Giesz, V; Lemaître, A; Sagnes, I; Auffèves, A; Senellart, P

    2017-06-23

    Solid-state emitters are excellent candidates for developing integrated sources of single photons. Yet, phonons degrade the photon indistinguishability both through pure dephasing of the zero-phonon line and through phonon-assisted emission. Here, we study theoretically and experimentally the indistinguishability of photons emitted by a semiconductor quantum dot in a microcavity as a function of temperature. We show that a large coupling to a high quality factor cavity can simultaneously reduce the effect of both phonon-induced sources of decoherence. It first limits the effect of pure dephasing on the zero-phonon line with indistinguishabilities above 97% up to 18 K. Moreover, it efficiently redirects the phonon sidebands into the zero-phonon line and brings the indistinguishability of the full emission spectrum from 87% (24%) without cavity effect to more than 99% (76%) at 0K (20K). We provide guidelines for optimal cavity designs that further minimize the phonon-induced decoherence.

  15. Modeling of plasmon mediated single-photon devices

    DEFF Research Database (Denmark)

    Chen, Yuntian

    The thesis describes the theoretical study of optical plasmons mediated light-matter interaction. We develop a finite element method to study spontaneous emission from emitters coupled to plasmonic waveguides. The numerical method is applied to calculate the coupling of a emitter coupled to a cyl......-based reconfigurable antenna to controllably distribute emission from a single emitter in spatially separated channels....... to a cylindrical nanowire, a square metallic nanowire and a metallic slot waveguide with inhomogenous dielectric environment. We also examine a quantum emitter coupled to optical nanoantennas. We mimic the conventional Yagi-Uda to realize its optical analogy for directional emission. We also propose a plasmon...

  16. Vertically integrated (Ga, In)N nanostructures for future single photon emitters operating in the telecommunication wavelength range.

    Science.gov (United States)

    Winden, A; Mikulics, M; Grützmacher, D; Hardtdegen, H

    2013-10-11

    Important technological steps are discussed and realized for future room-temperature operation of III-nitride single photon emitters. First, the growth technology of positioned single pyramidal InN nanostructures capped by Mg-doped GaN is presented. The optimization of their optical characteristics towards narrowband emission in the telecommunication wavelength range is demonstrated. In addition, a device concept and technology was developed so that the nanostructures became singularly addressable. It was found that the nanopyramids emit in the telecommunication wavelength range if their size is chosen appropriately. A p-GaN contacting layer was successfully produced as a cap to the InN pyramids and the top p-contact was achievable using an intrinsically conductive polymer PEDOT:PSS, allowing a 25% increase in light transmittance compared to standard Ni/Au contact technology. Single nanopyramids were successfully integrated into a high-frequency device layout. These decisive technology steps provide a promising route to electrically driven and room-temperature operating InN based single photon emitters in the telecommunication wavelength range.

  17. Triggered high-purity telecom-wavelength single-photon generation from p-shell-driven InGaAs/GaAs quantum dot.

    Science.gov (United States)

    Dusanowski, Ł; Holewa, P; Maryński, A; Musiał, A; Heuser, T; Srocka, N; Quandt, D; Strittmatter, A; Rodt, S; Misiewicz, J; Reitzenstein, S; Sęk, G

    2017-12-11

    We report on the experimental demonstration of triggered single-photon emission at the telecom O-band from In(Ga)As/GaAs quantum dots (QDs) grown by metal-organic vapor-phase epitaxy. Micro-photoluminescence excitation experiments allowed us to identify the p-shell excitonic states in agreement with high excitation photoluminescence on the ensemble of QDs. Hereby we drive an O-band-emitting GaAs-based QD into the p-shell states to get a triggered single photon source of high purity. Applying pulsed p-shell resonant excitation results in strong suppression of multiphoton events evidenced by the as measured value of the second-order correlation function at zero delay of 0.03 (and ~0.005 after background correction).

  18. Thallium-201 accumulation in cerebral candidiasis: Unexpected finding on SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Tonami, N.; Matsuda, H.; Ooba, H.; Yokoyama, K.; Hisada, K.; Ikeda, K.; Yamashita, J. (Kanazawa Univ. (Japan))

    1990-06-01

    The authors present an unexpected finding of Tl-201 uptake in the intracerebral lesions due to candidiasis. SPECT demonstrated the extent of the lesions and a high target-to-background ratio. The regions where abnormal Tl-201 accumulation was seen were nearly consistent with CT scans of those enhanced by a contrast agent. After treatment, most of the abnormal Tl-201 accumulation disappeared.

  19. Sequential thallium-201 myocardial scintigraphy after acute infarction in man

    Energy Technology Data Exchange (ETDEWEB)

    Fletcher, J.W.; Mueller, H.S.; Rao, P.S.

    1980-07-01

    Three sequential Tl-201 myocardial perfusion studies were performed in 21 patients (18 men, 3 women) with first acute transmural myocardia infarction. The Tl-201 image defect size was determined with a semiquantitative visual scoring method and temporal changes in image defect size were compared to CK-MB infarct size and enzymatic evidence of progressive myocardial necrosis and infarct extension. Progressive decreases in Tl-201 image defect size were observed and the visual score in all 21 patients decreased significantly from 6