WorldWideScience

Sample records for thallium-201 myocardial spect

  1. Evaluation of myocardial damage in Duchenne's muscular dystrophy with thallium-201 myocardial SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Tamura, Takuhisa; Shibuya, Noritoshi (Kawatana National Hospital, Nagasaki (Japan)); Hashiba, Kunitake; Oku, Yasuhiko; Mori, Hideki; Yano, Katsusuke

    1993-01-01

    Myocardial damage and cardiopulmonary functions in patients with Duchenne's muscular dystrophy (DMD) were assessed using thallium-201 myocardial single-photon emission computed tomography (SPECT) and technetium-99m multigated radionuclide angiography. Twenty-five patients with DMD were divided into 4 groups according to percent of perfusion defect (%PD) calculated by the bull's-eye method and age. PD was detected in 24 (96.0%) of 25 patients with DMD, and it spread from the left ventricular lateral wall to the anterior wall and/or interventricular septum. PD was detected even in a 6-year-old DMD boy. Patients in Group I (%PD[>=]10% and age<15 years old) were shown to have a higher risk of left-sided heart failure without respiratory failure. Patients in Group II (%PD[>=]10 and age[>=]15) showed decreased pulmonary function and worsened arterial blood gas values as compared with Group IV (%PD<10 and age[>=]15). There was no significant difference in cardiac function among the 4 groups. It is postulated that myocardial damage in Group II patients is dependent primarily on a deficiency of dystrophin and on chronic respiratory failure, and that some of them are at risk of cardiopulmonary failure. It is concluded that myocardial SPECT is useful for the early diagnosis of myocardial damage and evaluation of cardiopulmonary function in DMD patients. (author).

  2. Repeat thallium-201 SPECT in cerebral lymphoma.

    Science.gov (United States)

    Borggreve, F; Dierckx, R A; Crols, R; Mathijs, R; Appel, B; Vandevivere, J; Mariën, P; Martin, J J; De Deyn, P P

    1993-01-01

    The authors report on the contribution of Thallium-201 brain SPECT in the diagnosis and follow-up of a non-immunosuppressed patient, presenting with primary cerebral lymphoma. The tumoral process was at first not diagnosed on CT-scan, but Thallium-201 SPECT suggested a tumoral invasion. During corticosteroid treatment the tumor volume on CT-scan decreased, while on Thallium-201 SPECT there was an enhancement of the accumulation and an increasing tumor to non-tumor ratio. These scintigraphical findings more closely reflected the clinical course and the postmortem results.

  3. Biphasic thallium 201 SPECT-imaging for the noninvasive diagnosis of myocardial perfusion abnormalities in a child with Kawasaki disease--a case report

    Energy Technology Data Exchange (ETDEWEB)

    Hausdorf, G.; Nienaber, C.A.; Spielman, R.P.

    1988-02-01

    The mucocutaneous lymph node syndrome (Kawasaki disease) is of increasing importance for the pediatric cardiologist, for coronary aneurysms with the potential of thrombosis and subsequent stenosis can develop in the course of the disease. The authors report a 2 1/2-year-old female child in whom, fourteen months after the acute phase of Kawasaki disease, myocardial infarction occurred. Biphasic thallium 201 SPECT-imaging using dipyridamole depicted anterior wall ischemia and inferolateral infarction. This case demonstrates that noninvasive vasodilation-redistribution thallium 201 SPECT-imaging has the potential to predict reversible myocardial perfusion defects and myocardial necrosis, even in small infants with Kawasaki disease.

  4. Relationship between thallium-201 myocardial SPECT and findings of endomyocardial biopsy specimens in dilated cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Motohiro; Gotoh, Kohshi; Nagashima, Kenshi [Gifu Univ. (Japan). School of Medicine] (and others)

    2001-02-01

    The purpose of this study was to clarify which myocardial histological findings associated with dilated cardiomyopathy (DCM) are reflected in quantitative {sup 201}Tl myocardial SPECT. We obtained studied SPECT images from 21 patients with DCM 10 minutes and 2 hours after they received an injection of 111 MBq {sup 201}Tl at rest. We calculated the percent coefficient of variation of myocardial {sup 201}Tl counts [%CV(Tl)], the washout rate (WR), standard deviation of WR [SD(WR)], extent score (ES) and severity score (SS). We used image analysis to measure % fibrosis, % myocytes, the ratio of fibrous tissue to myocyte tissue (F/My), myocyte size and standard deviation of myocyte size [SD(My)] in left ventricular endomyocardial biopsy specimens. The %CV(Tl) was correlated with % fibrosis and F/My. The ES and SS also correlated with F/My. The correlation between SD(WR) and SD(My) was significant. The present findings suggest that %CV(Tl), ES and SS of rest {sup 201}Tl SPECT reflect myocardial fibrosis and that the standard deviation of washout reflects the distribution of myocyte size. (author)

  5. Reduced left ventricular cavitary activity ("black hole sign") in thallium-201 SPECT perfusion images of anteroapical transmural myocardial infarction.

    Science.gov (United States)

    Civelek, A C; Shafique, I; Brinker, J A; Durski, K; Weiss, J L; Links, J M; Natarajan, T K; Ozguven, M A; Wagner, H N

    1991-11-01

    Apparently reduced left ventricular (LV) cavitary thallium activity in both planar and tomographic perfusion images has been previously observed by these and other investigators. With single-photon emission computerized tomography, we have clinically noted that this "black hole sign" was associated with an aneurysm in the setting of a transmural anterior or anteroapical perfusion defect. We have now prospectively studied the etiology and predictive value of this sign in 84 consecutive patients with an anterior, anteroapical transmural perfusion defect. Of the 84 patients, 49 had both LV aneurysm (confirmed by contrast ventriculography, echocardiography or gated blood pool studies) and a black hole sign. Only 1 patient with an aneurysm did not have the black hole sign, and 2 without aneurysm did. Thus, it is concluded that this sign is highly accurate in diagnosing LV aneurysm. Because thallium-201 single-photon emission computerized tomography imaging is often performed as one of the first diagnostic tests soon after myocardial infarction, this has important clinical management implications.

  6. Comparison of 8-frame and 16-frame thallium-201 gated myocardial perfusion SPECT for determining left ventricular systolic and diastolic parameters.

    Science.gov (United States)

    Kurisu, Satoshi; Sumimoto, Yoji; Ikenaga, Hiroki; Watanabe, Noriaki; Ishibashi, Ken; Dohi, Yoshihiro; Fukuda, Yukihiro; Kihara, Yasuki

    2017-07-01

    The myocardial perfusion single photon emission computed tomography synchronized with the electrocardiogram (gated SPECT) has been widely used for the assessment of left ventricular (LV) systolic and diastolic functions using Quantitative gated SPECT. The aim of this study was to compare the effects of 8-frame and 16-frame thallium-201 (Tl-201) gated SPECT for determining LV systolic and diastolic parameters. The study population included 42 patients with suspected coronary artery disease who underwent gated SPECT by clinical indication. LV systolic and diastolic parameters were assessed on 8-frame and 16-frame gated SPECT. There were good correlations in end-diastolic volume (r = 0.99, p < 0.001), end-systolic volume (ESV) (r = 0.97, p < 0.001) and ejection fraction (EF) (r = 0.95, p < 0.001) between 8-frame and 16-frame gated SPECT. Bland-Altman plot showed a significant negative slope of -0.08 in EDV indicating a larger difference for larger EDV. Eight-frame gated SPECT overestimated ESV by 2.3 ml, and underestimated EF by -4.2% than 16-frame gated SPECT. There were good correlations in peak filling rate (PFR) (r = 0.87, p < 0.001), one third mean filling rate (r = 0.87, p < 0.001) and time to PFR (r = 0.61, p < 0.001) between 8-frame and 16-frame gated SPECT. Eight-frame gated SPECT underestimated PFR by -0.22 than 16-frame gated SPECT. Eight-frame gated SPECT estimated as much MFR/3 and TPFR as 16-frame gated SPECT. According to the data, the study suggested that 8-frame Tl-201 gated SPECT could underestimate systolic and/or diastolic parameter when compared with 16-frame gated SPECT.

  7. Exercise-induced thallium-201 myocardial perfusion defects in angina pectoris without significant coronary artery stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Nakazato, Masayasu; Maruoka, Yuji; Sunagawa, Osahiko; Kinjo, Kunihiko; Tomori, Masayuki; Fukiyama, Koshiro (Ryukyu Univ., Nishihara, Okinawa (Japan). School of Medicine)

    1990-01-01

    We performed exercise thallium-201 myocardial scintigraphy in 32 patients with angina pectoris to study the incidence of perfusion defects, who had no significant organic stenosis on coronary angiography. None of them had myocardial infarction or cardiomyopathy. Thallium-201 myocardial scintigraphy and 12-lead ECG recording were performed during supine bicycle ergometer exercise. Perfusion defects in thallium-201 scintigrams in SPECT images were assessed during visual analysis by two observers. In the coronary angiograms obtained during intravenous infusion of nitroglycerin, the luminal diameter of 75% stenosis or less in the AHA classification was regarded as an insignificant organic stenosis. Myocardial perfusion defects in the thallium-201 scintigrams were detected in eight (25%) of the 32 patients. Six of these eight patients had variant angina documented during spontaneous attacks with ST elevations in standard 12-lead ECGs. Perfusion defects were demonstrated at the inferior or infero-posterior regions in six patients, one of whom had concomitant anteroseptal defect. The defects were not always accompanied by chest pain. All but one patient demonstrating inferior or inferoposterior defects showed ST depression in leads II, III and aV{sub F} on their ECGs, corresponding to inferior wall ischemia. The exception was a case with right bundle branch block. Thus, 25% of the patients with angina pectoris, who had no evidence of significant organic stenosis on their coronary angiograms, exhibited exercise-induced perfusion defects in their thallium-201 scintigrams. Coronary spasms might have caused myocardial ischemia in these patients. (author).

  8. Technetium-99m pyrophosphate/thallium-201 dual-isotope SPECT imaging predicts reperfusion injury in patients with acute myocardial infarction after reperfusion

    Energy Technology Data Exchange (ETDEWEB)

    Akutsu, Yasushi; Kaneko, Kyouichi; Kodama, Yusuke; Li, Hui-Ling; Nishimura, Hideki; Hamazaki, Yuji; Kobayashi, Youichi [Showa University School of Medicine, Division of Cardiology, Department of Medicine, Tokyo (Japan); Suyama, Jumpei; Shinozuka, Akira; Gokan, Takehiko [Showa University School of Medicine, Department of Radiology, Tokyo (Japan)

    2009-02-15

    Microcirculatory failure after reperfusion is clinically indicated to cause reperfusion injury whereas excessive intracellular calcium ion overload is experimentally proved as a key mechanism of reperfusion injury. We hypothesized that technetium-99m ({sup 99m}Tc) pyrophosphate (Tc-PYP) uptake in injured but viable infarct-related myocardium with preserved myocardial perfusion after reperfusion estimated by thallium-201 ({sup 201}Tl) uptake would be associated with final functional recovery. Dual-isotope Tc-PYP/{sup 201}Tl single-photon emission computed tomography (SPECT) was performed 2 days after successful reperfusion therapy in patients with first acute myocardial infarction, and 50 patients (63 {+-} 13 years old, female 22%) with preserved {sup 201}Tl uptakes of {>=}50% in reperfused myocardium was followed for 1 month. Tc-PYP uptake was assessed as the heart-to-sternum (H/S) ratio. Two-dimensional echocardiography was also performed 2 days and 1 month after reperfusion to evaluate functional recovery. High Tc-PYP uptake, defined as the H/S ratio {>=}0.81, was predictive of chronic phase no functional recovery (73.7% in 14 of 19 patients with high uptake vs 16.1% in five of 31 patients without those, p < 0.0001). After adjustment for potential confounding variables, including electrocardiographic persistent ST segment elevation at 1 h after reperfusion, high Tc-PYP uptake remained independently predictive of no functional recovery with odds ratio of 8.7 (95% confidential interval = 2 to 38.7; p = 0.005). High Tc-PYP uptake in reperfused but viable infarct-related myocardium was a powerful predictor of no functional recovery, which may reflect excessive intracellular calcium ion overload caused by reperfusion injury. Tc-PYP/{sup 201}Tl dual-isotope SPECT imaging can provide prognostic information after reperfusion. (orig.)

  9. Indium-111 antimyosin antibody imaging and thallium-201 imaging. A comparative myocardial scintigraphic study using single-photon emission computed tomography in patients with myocarditis and dilated cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Takehiko; Matsumori, Akira; Nohara, Ryuji; Konishi, Junji; Sasayama, Shigetake [Kyoto Univ. (Japan). Faculty of Medicine; Tamaki, Nagara

    1997-10-01

    Indium-111 antimyosin antibody imaging (a tracer of myocardial necrosis) and thallium-201 imaging (a tracer of myocardial perfusion) were compared in patients with myocarditis and dilated cardiomyopathy. The distribution of each tracer and antimyosin/thallium-201 overlapping were evaluated with single-photon emission computed tomography (SPECT). Scintigraphic data were classified into 5 patterns according to the distribution of both images and were compared with histologic findings of endomyocardial biopsy: AM-D, intense and diffuse antimyosin uptake and no perfusion abnormality (active myocarditis); AM-L, localized antimyosin uptake and no perfusion abnormality (active myocarditis); HM, no antimyosin uptake with or without perfusion abnormality (healed myocarditis); DCM-NH, diffuse antimyosin uptake and inhomogeneous thallium-201 uptake (dilated cardiomyopathy); DCM-PD, diffuse or localized antimyosin uptake and myocardial perfusion defect(s) (dilated cardiomyopathy). Patients with dilated-phase hypertrophic cardiomyopathy were frequently found in the DCM-PD group. Taken together, comparative antimyosin/thallium-201 SPECT images are useful for evaluating the activity of myocarditis and ongoing myocardial damage even in areas with no perfusion in patients with dilated cardiomyopathy. (author)

  10. Thallium-201 accumulation in cerebral candidiasis: Unexpected finding on SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Tonami, N.; Matsuda, H.; Ooba, H.; Yokoyama, K.; Hisada, K.; Ikeda, K.; Yamashita, J. (Kanazawa Univ. (Japan))

    1990-06-01

    The authors present an unexpected finding of Tl-201 uptake in the intracerebral lesions due to candidiasis. SPECT demonstrated the extent of the lesions and a high target-to-background ratio. The regions where abnormal Tl-201 accumulation was seen were nearly consistent with CT scans of those enhanced by a contrast agent. After treatment, most of the abnormal Tl-201 accumulation disappeared.

  11. Quantitative evaluation of thallium-201 myocardial scintigram in coronary artery diseases

    Energy Technology Data Exchange (ETDEWEB)

    Mikada, Ken-etsu (Akita Univ. (Japan). School of Medicine)

    1992-11-01

    Quantitative indices from circumferential profile curves of thallium-201 ([sup 201]Tl) myocardial scintigram were evaluated for diagnostic utility in coronary artery diseases (CAD). Myocardial [sup 201]Tl scintigrams with single photon emission computed tomography (SPECT) were obtained 5 minutes (early) and 4 hours (delayed) after exercise in 20 normal subjects and 66 cases of CAD, of which 20 were angina pectoris without myocardial infarction (AP), 14 were subendocardial infarction (non-QMI) and 32 were Q-wave infarction (QMI). Tl counts, %Tl uptake and washout ratio (WR) were measured in 81 segments (9 apical segments of the slice from the longitudinal axis and all 72 segments of two slices from the short axis). A mean early defect (MED), a mean delayed defect (MDD), a mean delta washout rate (MDR), and a [Sigma] delayed defect ([Sigma]DD) were calculated from the areas which were below the two standard deviations of the mean %Tl uptake in normal subjects. A mean filling-in (MFI) was calculated from the difference of the %Tl uptake between early and delayed curves in each patient. In patients with CAD, the MED and MFI were higher, but MDW was lower with a more severe coronary stenosis, indicating that these indices were useful to detect myocardial hypo-perfuion. In severely stenotic regions, the MDD was higher in QMI than in AP and non-QMI, indicating that the ratio of infarct to the myocardium in the region was higher in QMI. In QMI, [Sigma]DD correlated well (r=0.723) with Total Wall Motion Scores with two-dimentional echocardiography which was directly related with infarct size. Further, MED, MFI and MDW were improved after aortocoronary bypass only in patients with patent graft. It is concluded that this quantitative evaluation with [sup 201]Tl-SPECT can provide an objective and quantitative estimate of regional myocardial ischemia and infarct. (author).

  12. New CZT cardiac cameras and myocardial perfusion imaging with thallium 201; Nouvelles cameras cardiaques a semi-conducteur cadmium -zinc- telluride (CZT) et scintigraphies myocardiques au thallium 201

    Energy Technology Data Exchange (ETDEWEB)

    Songy, B. [Service de medecine et imagerie nucleaire, centre cardiologique du Nord (CCN), 93 - Saint-Denis (France)

    2010-08-15

    Myocardial perfusion imaging is widely used for management of coronary artery disease. However, it suffers from technical limitations. New cardiac cameras using CZT detectors are now available and increase spatial (x2) and energy (x2) resolutions and photons sensitivity (x5). We describe here the General Electric Discovery NM 530c new camera and summarize the validation studies with technetium agents and with thallium 201, protocols to reduce doses, ultrafast protocols and perspectives offered with this new technology. (author)

  13. Evaluation of myocardial abnormalities in collagen diseases by thallium-201 myocardial scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Yamano, Shigeru; Kagoshima, Tadashi; Sugihara, Kiyotaka (Nara Medical Univ., Kashihara (Japan)) (and others)

    1993-12-01

    This study was performed to evaluate myocardial abnormalities in patients with collagen diseases by exercise and rest thallium-201 myocardial scintigrams. A total of 65 patients without ischemic ECG changes, consisting of 18 with systemic lupus erythematosus (SLE), 18 with polymyositis (PM), 8 with progressive systemic sclerosis (PSS), and 21 with Sjoegren's syndrome (SjS), was enrolled in this study. Reversible exercise-induced defects scintigraphically suggesting myocardial ischemia were noted in 8 cases of SLE, 4 cases of PM, 4 cases of PSS, and 3 cases of SjS. Nineteen patients had exercise-induced defects and underwent cardiac catheterization, 8 of whom had normal coronary angiograms. Fixed hypoperfusion areas were observed in one case of SLE, 6 cases of PM and 3 cases of SjS. Rest thallium-201 myocardial scintigram disclosed hypoperfusion areas which were not induced by exercise in 2 cases of SLE, 3 cases of PM, one case of PSS and 5 cases of SjS. Echocardiogram showed no significant differences in ejection fraction and % fractional shortening between the disease groups and healthy control group. These findings suggest that patients with collagen diseases have abnormalities of coronary circulation at the level of the intramural vasculature before cardiac function impairment, myocardial fibrosis and functional abnormalities at the cell membrane. (author).

  14. Comparative studies on right ventricular pressure and volume overloading by thallium-201 myocardial scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Owada, K.; Tsukahara, Y.; Kijima, M.; Miyazaki, Y.; Ono, K. (Fukushima Medical Coll. (Japan))

    1982-03-01

    Thallium-201 myocardial scintigraphy was performed in 44 patients with various heart diseases including mitral stenosis, atrial septal defect, primary pulmonary hypertension, and left atrial myxoma. The morphological findings of right ventricular (RV) free wall on the scintigram and RV/IVS (interventricular septum) uptake ratio of the images obtained from the left anterior oblique projection were studied in the patients with RV pressure or volume overloading.

  15. Thallium-201 SPECT in the diagnosis of head and neck cancer.

    Science.gov (United States)

    Valdés Olmos, R A; Balm, A J; Hilgers, F J; Koops, W; Loftus, B M; Tan, I B; Muller, S H; Hoefnagel, C A; Gregor, R T

    1997-06-01

    The accuracy of SPECT with 201Tl-chloride for the diagnosis of primary tumors, lymph node metastases and recurrences in head and neck cancer was evaluated for clinical applicability. SPECT images, obtained 60 min after administration of 150 MBq 201Tl-chloride, were compared with clinical, CT and/or MRI and histology results. In addition, whole-body images were obtained to detect distant metastases. In 79 patients studied for primary tumors (principally larynix, hypopharynx, oropharynx, nasopharynx and oral cavity), 201Tl SPECT correctly identified 69 of 73 (95% versus 88% for CT/MRI) histologically confirmed malignancies including 63 squamous-cell carcinomas. The method localized four occult naso- and oropharynx carcinomas not seen on CT/MRI and was correctly negative in two patients without tumor and in three of four patients with no confirmed primary tumor in the head and neck. With respect to regional spread, only patients who had cervical lymph node dissection were evaluated, and the findings were recorded per side of the neck. Thallium-201 SPECT correctly identified metastases in 31 of 36 neck dissections with proven lymph node involvement (86%), was correctly negative in nine and false-positive in one. Although the sensitivity of CT/MRI was clearly higher (97%), considerably more false-positive cases affected its accuracy (81% versus 87% for SPECT). In 30 patients investigated for recurrences, 201Tl SPECT correctly identified 27 of 29 microscopically confirmed tumor sites (93%) and was correctly negative in seven. Sensitivity of CT/MRI was lower (76%), and a greater number of false-positives (seven versus three for SPECT) further decreased its accuracy (64% versus 87% for SPECT). Distant metastases were detected in five patients. Thallium-201 SPECT appears to be an accurate method for the diagnosis of head and neck cancer. The method is particularly useful for detection of occult head and neck tumors and for assessing recurrences. It also may be of

  16. Dipyridamole-thallium-201 tomography documenting improved myocardial perfusion with therapy in Kawasaki disease

    Energy Technology Data Exchange (ETDEWEB)

    Nienaber, C.A.; Spielmann, R.P.; Hausdorf, G.

    1988-12-01

    Thallium-201 tomographic perfusion studies after pharmacologic vasodilation were performed in seven children (aged 2 years 8 months to 8 years 7 months), 3 to 20 months after the acute stage of the disease. In all patients coronary aneurysms were seen on cross-sectional echocardiograms. The scintigrams of six children showed no significant regional reduction of myocardial thallium-201 uptake. These children had remained asymptomatic in the follow-up period after the acute inflammatory stage of Kawasaki disease. Persistent and transient thallium defects were present in one child with acute posterolateral myocardial infarction; obstruction of two coronary vessels supplying the defect zones was confirmed by contrast angiography. After 8 months of treatment a follow-up nuclear scan showed marked reduction in the size of the defect and almost complete abolishment of the ischemic reaction. Thus tomographic thallium-201 perfusion scintigraphy in conjunction with vasodilation stress is useful to assess myocardial perfusion in children with Kawasaki disease and demonstrates marked improvement in regional perfusion after adequate medical therapy.

  17. Evaluation of myocardial abnormalities in patients with collagen diseases by thallium-201 myocardial scintigram

    Energy Technology Data Exchange (ETDEWEB)

    Yamano, Shigeru (Nara Medical Univ., Kashihara (Japan))

    1992-08-01

    This study was performed to evaluate myocardial lesions in patients with collagen diseases by rest and exercise thallium-201 myocardial scintigraphies. A total of 76 patients without ischemic ECG changes, consisting of 27 cases of systemic lupus erythematosus (SLE), 17 cases of polymyositis or dermatomyositis (PM[center dot]DM), 11 cases of progressive systemic sclerosis (PSS), and 21 cases of Sjoegren's syndrome (SjS), were enrolled in this study. Reversible exercise-induced defects suggesting myocardial ischemia were noted in 12 cases of SLE, 5 cases of PM[center dot]DM, 3 cases of PSS, and 3 cases of SjS. Of the 23 patients who had exercise-induced defects, 9 patients showed normal coronary angiograms by cardiac catheterization. Fixed hypoperfusion areas were observed in 5 cases of SLE, 6 cases of PM[center dot]DM, 4 cases of PSS and 3 cases of SjS. Rest thallium-201 myocardial scintigraphy disclosed hypoperfusion areas, which were not induced by exercise, in 1 case of SLE, 4 cases of PM[center dot]DM, 1 case of PSS and 5 cases of SjS. Endomyocardial biopsy was performed on 20 patients. Myocardial lesions in PM[center dot]DM and PSS were more severe and wide spread than in SLE. Ejection fraction and fractional shortening evaluated by echocardiography had no significant differences between each disease group and the healthy control group. These findings suggest that patients with collagen diseases show the presence of abnormalities of coronary circulation at the level of the intramyocardial vasculature in the stage before impairment of cardiac function, myocardial fibrosis and functional abnormalities of the cell membrane level that were not dependent on myocardial ischemia. (author).

  18. MRI and thallium-201 SPECT in the prediction of survival in glioma

    Energy Technology Data Exchange (ETDEWEB)

    Vos, Maaike J. [VU University Medical Center, Department of Neurology, Amsterdam (Netherlands); Medical Center Haaglanden, Department of Neurology, PO Box 432, The Hague (Netherlands); Berkhof, Johannes [VU University Medical Center, Department of Epidemiology and Biostatistics, Amsterdam (Netherlands); Hoekstra, Otto S. [VU University Medical Center, Department of Nuclear Medicine and PET Research, Amsterdam (Netherlands); Bosma, Ingeborg; Sizoo, Eefje M.; Heimans, Jan J.; Reijneveld, Jaap C.; Postma, Tjeerd J. [VU University Medical Center, Department of Neurology, Amsterdam (Netherlands); Sanchez, Esther [VU University Medical Center, Department of Radiology, Amsterdam (Netherlands); Lagerwaard, Frank J. [VU University Medical Center, Department of Radiation Oncology, Amsterdam (Netherlands); Buter, Jan [VU University Medical Center, Department of Medical Oncology, Amsterdam (Netherlands); Noske, David P. [VU University Medical Center, Department of Neurosurgery and Neuro-Oncology Research Group, Amsterdam (Netherlands)

    2012-06-15

    This paper aims to study the value of MRI and Thallium 201 ({sup 201}Tl) single-photon emission computed tomography (SPECT) in the prediction of overall survival (OS) in glioma patients treated with temozolomide (TMZ) and to evaluate timing of radiological follow-up. We included patients treated with TMZ chemoradiotherapy for newly diagnosed glioblastoma multiforme (GBM) and with TMZ for recurrent glioma. MRIs and {sup 201}Tl SPECTs were obtained at regular intervals. The value of both imaging modalities in predicting OS was examined using Cox regression analyses. Altogether, 138 MRIs and 113 {sup 201}Tl SPECTs in 46 patients were performed. Both imaging modalities were strongly related to OS (P {<=} 0.02). In newly diagnosed GBM patients, the last follow-up MRI (i.e., after six adjuvant TMZ courses) and SPECT (i.e., after three adjuvant TMZ courses) were the strongest predictors of OS (P = 0.01). In recurrent glioma patients, baseline measurements appeared to be the most predictive of OS (P < 0.01). The addition of one imaging modality to the other did not contribute to the prediction of OS. Both MRI and {sup 201}Tl SPECT are valuable in the prediction of OS. It is adequate to restrict to one of both modalities in the radiological follow-up during treatment. In the primary GBM setting, MRI after six adjuvant TMZ courses contributes significantly to the prediction of survival. In the recurrent glioma setting, baseline MRI appears to be a powerful predictor of survival, whereas follow-up MRIs during TMZ seem to be of little additional value. (orig.)

  19. Sequential thallium-201 myocardial scintigraphy after acute infarction in man

    Energy Technology Data Exchange (ETDEWEB)

    Fletcher, J.W.; Mueller, H.S.; Rao, P.S.

    1980-07-01

    Three sequential Tl-201 myocardial perfusion studies were performed in 21 patients (18 men, 3 women) with first acute transmural myocardia infarction. The Tl-201 image defect size was determined with a semiquantitative visual scoring method and temporal changes in image defect size were compared to CK-MB infarct size and enzymatic evidence of progressive myocardial necrosis and infarct extension. Progressive decreases in Tl-201 image defect size were observed and the visual score in all 21 patients decreased significantly from 6.5 +- 3.7 (mean +- SD) on day 1 to 4.9 +- 3.5 on day 12. Eleven patients without evidence of infarct extension had significantly lower infarct size, a significant decrease in visual score by the 12th day and had significantly smaller Tl-201 defects at all three study times compared to 10 patients with infarct extension. Seven of 10 (70%) with extension had an initial visual score greater than or equal to 7 compared to only 2/11 (18%) without extension. The temporal behavior of Tl-201 image defects is related to the size of the infarction and presence or absence of extension. Sequential studies comparing early initial and subsequent defect size may assist in evaluating the behavior of ischemic and infarcted myocardium in the postinfarction period.

  20. Usefulness of thallium-201 SPECT in the evaluation of tumor natures in intracranial meningiomas

    Energy Technology Data Exchange (ETDEWEB)

    Takeda, Tetsuji; Nakano, Takahiro; Asano, Kenichiroh; Shimamura, Norihito; Ohkuma, Hiroki [Hirosaki University Graduate School of Medicine, Department of Neurosurgery, Hirosaki (Japan)

    2011-11-15

    Although intracranial meningiomas are regarded as benign tumors, some of them behave clinically as malignant tumors. Past reports suggest that MIB 1 and vascular endothelial growth factor (VEGF) in postoperative tumor specimens correlate with the aggressive nature of tumors, but preoperative prediction of such a nature is more useful for therapeutic planning for the tumor. The purpose of this study was to assess the usefulness of preoperative thallium-201 chloride single-photon emission computed tomography (Tl SPECT) to evaluate biological behavior in intracranial meningiomas. Tl SPECT was performed on 39 patients with intracranial meningioma and Tl uptake indices were calculated. The difference in the Tl uptake index between atypical meningiomas and other pathological types of meningioma was evaluated. Moreover, correlation of Tl uptake indices with the MIB1 labeling index was estimated. Tl uptake indices were also compared between VEGF strongly positive and weakly positive meningiomas. The delayed index of atypical meningioma was significantly higher than that of the other pathological types (p = 0.036). Significant correlation was found between the Tl uptake index in the delayed image and MIB1 labeling index (p < 0.0001, R{sup 2} = 0.36). Moreover, VEGF strongly positive meningiomas exhibited a significantly higher Tl uptake index compared to VEGF weakly positive meningiomas in both the early image and the delayed image (p = 0.029, 0.023, respectively). Tl uptake index may be a possible preoperative surrogate marker of MIB1 and VEGF that is useful in detecting aggressive natures in intracranial meningiomas. (orig.)

  1. Clinicopathologic correlation study of thallium-201 myocardial scintigraphy in diagnosis of myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Chida, Kouji; Sugiura, Masaya; Ohkawa, Shin-ichiro

    1987-05-01

    In a series of 1,000 consecutive autopsy cases, we evaluated the clinical utility of thallium-201 (Tl-201) myocardial scintigraphy and electrocardiography (ECG) in 101 patients who had been studied while alive. Fifty-five cases had myocardial infarctions (MI) at autopsy. The Tl-201 scintigram and ECG in diagnosis of MI showed sensitivities of 68 % and 60 %, specificities of 87 % and 83 %, and diagnostic accuracies of 76 % and 70 %, respectively. The sensitivity of the Tl-201 scintigram was 70 % in anterior MI, 80 % in postero-inferior MI, 25 % in lateral and subendocardial infarction. The sensitivity was 88 % for large massive MI, but was low in scattered (50 %) or middle-sized MI (17 %). The diagnostic limit of the resolution of Tl-201 scintigrams was 4.5 cm in long diameter. All 8 cases with MI of less than 4 cm could not be diagnosed with the technique. There were 48 cases of large MI (more than 5 cm), but 8 cases could not be diagnosed by scintigraphy because of non-transmural or scattered MI. A comparison of the Tl-201 scintigram and ECG showed that 27 cases out of 60 cases were diagnosed by both methods, 14 only by the Tl-201 scintigram, 9 only by ECG and 10 by neither method.

  2. Comparison of arbutamine stress and treadmill exercise thallium-201 SPECT: Hemodynamics, safety profile and diagnostic accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Kiat, H.; Berman, D.S. [Cedars-Sinai Medical Centre, Los Angeles, California, LA (United States)

    1998-02-01

    Full text: Arbutamine (ARB), a new pharmacologic stress agent with enhanced chronotropic property compared to dobutamine, was compared with treadmill (TM) exercise testing (Ex) in a multicenter study using thallium-201 (Tl) SPECT. Of the total of 184 patients who underwent ARB, 69 also had TM stress and quantitative coronary angiography. Fifty-eight patients with a low pretest likelihood of CAD also underwent ARB study for evaluation of test specificity (normalcy rate). Tl scans were scored by a central laboratory using a 20 segment (seg)/scan visual analysis (5 point system: 0=normal, 4-absent uptake). Maximum heart rate (HR) by ARB and Ex was 122 vs 141 bpm (p<0.05). Mean %HR change from baseline was similar (79% vs 82%, respectively, p=ns). Maximum systolic BP for ARB and Ex was 173 vs 175 mmHg, and mean % change from baseline was 24% vs 28% (p=ns). Sensitivity for detecting CAD (270% stenosis) by ARB Tl was 94% and 97% by Ex Tl (p=ns). Stress Tl SPECT segmental agreement for presence of defect between ARB and Ex was 92% (kappa=0.8, p<0.001). Exact segmental stress Tl score (0-4 grading) agreement was 83 % (kappa=0.7, p<0.001). Among 346 segs with stress defects by both ARB and Ex defect reversibility agreement was 86% (kappa=0.7, p<0.001). The normalcy rate for ARB TI-SPECT among patients with a low likelihood of CAD was 90%. Adverse events were mostly mild (tremor: 23%, flushing: 10%, headache: 10%, paraesthesia: 8%, dizziness: 8%, hot flushes: 4%). Arrhythimia of clinical concern occurred in 8% (10/122) of ARB patients who had cardiac catheterisation and in 1.4% (1/69) of patients who had stress Tl. Of all 184 patients with ARB stress, ARB was discontinued due to arrhythmia in 7(5%) and 1 patient had IV Metoprolol for frequent ventricular couplets. Sustained arrhythmias were not observed

  3. Thallium-201 single photon emission computed tomography (SPECT) in patients with Duchenne's progressive muscular dystrophy. A histopathologic correlation study

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, Toru; Yanagisawa, Atsuo; Sakata, Konomi; Shimoyama, Katsuya; Yoshino, Hideaki; Ishikawa, Kyozo [Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine; Sakata, Hitomi; Ishihara, Tadayuki

    2001-02-01

    The pathomorphologic mechanism responsible for abnormal perfusion imaging during thallium-201 myocardial single photon emission computed tomography ({sup 201}Tl-SPECT) in patients with Duchenne's progressive muscular dystrophy (DMD) was investigated. Hearts from 7 patients with DMD were evaluated histopathologically at autopsy and the results correlated with findings on initial and delayed resting {sup 201}Tl-SPECT images. The location of segments with perfusion defects correlated with the histopathologically abnormal segments in the hearts. Both the extent and degree of myocardial fibrosis were severe, especially in the posterolateral segment of the left ventricle. Severe transmural fibrosis and severe fatty infiltration were common in segments with perfusion defects. In areas of redistribution, the degree of fibrosis appeared to be greater than in areas of normal perfusion; and intermuscular edema was prominent. Thus, the degree and extent of perfusion defects detected by {sup 201}Tl-SPECT were compatible with the histopathology. The presence of the redistribution phenomenon may indicate ongoing fibrosis. Initial and delayed resting {sup 201}Tl-SPECT images can predict the site and progress of myocardial degeneration in patients with DMD. (author)

  4. Functional significance of myocardial perfusion defects induced by dipyridamole using thallium-201 single-photon emission computed tomography and two-dimensional echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Jain, A.; Suarez, J.; Mahmarian, J.J.; Zoghbi, W.A.; Quinones, M.A.; Verani, M.S. (Baylor College of Medicine, Houston, TX (USA))

    1990-10-01

    The mechanisms responsible for inhomogeneous myocardial blood flow after oral administration of a large dose (300 mg) of dipyridamole were assessed in 27 patients with serial thallium-201 single-photon emission computed tomography (SPECT) and simultaneous 2-dimensional echocardiograms. Myocardial tomographic images were obtained 50 minutes and 3 to 4 hours after administration of dipyridamole. Two-dimensional echocardiograms were recorded at baseline and then every 15 minutes for 60 minutes. Dipyridamole caused only a mild reduction in blood pressure (from 129 +/- 18 to 126 +/- 16 mm Hg) and a mild increase in heart rate (from 69 +/- 15 to 73 +/- 4 beats/min). Sixteen patients had perfusion defects after dipyridamole by SPECT, which underwent partial or total filling-in. Fourteen of these patients (87.5%) had either a new abnormality or further deterioration of a preexisting wall motion abnormality by 2-dimensional echocardiography, and thus were considered to have developed transient ischemia during dipyridamole administration. Ten of 11 patients (91%) with normal perfusion or fixed defects by SPECT had no further deterioration in wall motion after oral dipyridamole, and were thus considered to have no evidence of myocardial ischemia. In conclusion, most patients with transient thallium-201 defects after dipyridamole develop transient worsening of resting wall motion by 2-dimensional echocardiography, suggestive of true myocardial ischemia. Because myocardial oxygen demand, as indicated by the heart rate-blood pressure product, did not change significantly, the mechanism of myocardial ischemia in these patients is likely to be diminished regional blood flow related to a subendocardial steal induced by dipyridamole.

  5. Dual myocardial single photon emission computed tomography (SPECT) using thallium-201 and I-123-{beta}-methyl-i-pentadecanoic acid in patients with Duchenne's progressive muscular dystrophy

    Energy Technology Data Exchange (ETDEWEB)

    Shimoyama, Katsuya [Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine

    1999-10-01

    Dual single photon emission computed tomography (SPECT) was performed in 31 patients with Duchenne's progressive muscular dystrophy (DMD) using {sup 123}I-{beta}-methyl pentadecanoic acid (BMIPP) for myocardial fatty acid metabolism and {sup 201}thallium (Tl)-chloride for myocardial perfusion. The left ventricle was divided into 9 segments, and accumulation of the radiotracers was assessed visually for each segment to calculate defect score for each tracer. There was some degree of decrease in myocardial accumulation of both tracers in all DMD patients. Reduced accumulation was most common at the apex (BMIPP: 67%, Tl: 63%), followed by the posterior wall, lateral wall, and anterior wall. On the other hand, reduced accumulation was less common at the septum. BMIPP showed a higher accumulation than Tl in all segments but the septum. When BMIPP defect score was larger than Tl defect score, BMIPP defect score tended to increase during 4 years follow-up (p<0.042). However, when Tl defect score was larger than BMIPP defect score, an increase in Tl defect score was slight. A significant negative correlation was found between the sum of the BMIPP and Tl defect scores and the left ventricular ejection fraction (LVEF) (r=0.66, p<0.0001). According to the histo-pathological study of two autopsied hearts, severe myocardial fibrosis was seen in segments with fixed perfusion defect. In addition, the mismatched segments of BMIPP defect score > Tl defect score revealed a slight fibrosis or normal myocardium. It can be concluded that the dual SPECT myocardial scintigraphy using BMIPP and Tl provides accurate information about disease progression of the heart in patients with DMD by detecting abnormalities of the myocardial metabolism of each substance, thereby enabling the assessment of left ventricular function. (author)

  6. Diagnostic value of thallium-201 myocardial perfusion IQ-SPECT without and with computed tomography-based attenuation correction to predict clinically significant and insignificant fractional flow reserve: A single-center prospective study.

    Science.gov (United States)

    Tanaka, Haruki; Takahashi, Teruyuki; Ohashi, Norihiko; Tanaka, Koichi; Okada, Takenori; Kihara, Yasuki

    2017-12-01

    The aim of this study was to clarify the predictive value of fractional flow reserve (FFR) determined by myocardial perfusion imaging (MPI) using thallium (Tl)-201 IQ-SPECT without and with computed tomography-based attenuation correction (CT-AC) for patients with stable coronary artery disease (CAD).We assessed 212 angiographically identified diseased vessels using adenosine-stress Tl-201 MPI-IQ-SPECT/CT in 84 consecutive, prospectively identified patients with stable CAD. We compared the FFR in 136 of the 212 diseased vessels using visual semiquantitative interpretations of corresponding territories on MPI-IQ-SPECT images without and with CT-AC.FFR inversely correlated most accurately with regional summed difference scores (rSDS) in images without and with CT-AC (r = -0.584 and r = -0.568, respectively, both P < .001). Receiver-operating characteristics analyses using rSDS revealed an optimal FFR cut-off of <0.80 without and with CT-AC. Although the diagnostic accuracy of FFR <0.80 did not significantly differ, FFR ≥0.82 was significantly more accurate with, than without CT-AC. Regions with rSDS ≥2 without or with CT-AC predicted FFR <0.80, and those with rSDS ≤1 without and with CT-AC predicted FFR ≥0.81, with 73% and 83% sensitivity, 84% and 67% specificity, and 79% and 75% accuracy, respectively.Although limited by the sample size and the single-center design, these findings showed that the IQ-SPECT system can predict FFR at an optimal cut-off of <0.80, and we propose a novel application of CT-AC to MPI-IQ-SPECT for predicting clinically significant and insignificant FFR even in nonobese patients. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  7. Comparison of glucose-insulin-thallium-201 infusion single photon emission computed tomography (SPECT), stress-redistribution-reinjection thallium-201 SPECT and low dose dobutamine echocardiography for prediction of reversible dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Sakamoto, Hiroki; Kondo, Makoto; Motohiro, Masayuki; Usami, Satoru [Shimada Municipal Hospital, Shizuoka (Japan)

    2001-12-01

    The usefulness of glucose-insulin-thallium-201 (GI-Tl) infusion single photon emission computed tomography (SPECT) in predicting reversible dysfunction has not been evaluated, so the present study recruited 20 patients with regional ischemic dysfunction for investigation. All patients underwent GI-Tl SPECT, post-stress Tl reinjection imaging and low dose dobutamine echocardiography. The diagnostic accuracy of these 3 techniques in predicting functional recovery was evaluated by receiver operating characteristic (ROC) analysis. In segments with functional recovery, regional Tl activities of GI-Tl SPECT were significantly higher than those of reinjection imaging (p<0.05), although there were no significant differences in segments without recovery. The area under the ROC curve for GI-Tl SPECT (0.75{+-}0.06) was greater than that for reinjection imaging (0.68{+-}0.07). The optimal cutoff values to identify viable myocardium were considered to be 55% of peak activity for GI-Tl SPECT and 50% for reinjection imaging. At this cutoff point, the sensitivity and specificity for detection of functional recovery were, respectively, 85% and 61% for GI-Tl SPECT, and 73% and 61% for reinjection imaging. Dobutamine echocardiography had the same sensitivity (85%), but lower specificity (48%) than GI-Tl SPECT. Continuous infusion of GI-Tl solution enhances regional Tl uptake compared with conventional post-stress reinjection imaging. This study suggests that GI-Tl SPECT is superior to reinjection imaging and dobutamine echocardiography in predicting functional recovery after ischemic left ventricular dysfunction. (author)

  8. Septal myocardial perfusion imaging with thallium-201 in the diagnosis of proximal left anterior descending coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Pichard, A.D.; Wiener, I.; Martinez, E.; Horowitz, S.; Patterson, R.; Meller, J.; Goldsmith, S.J.; Gorlin, R.; Herman, M.V.

    1981-07-01

    The use of myocardial perfusion imaging (MPI) to identify obstructive coronary disease of the left anterior descending coronary artery proximal to the first septal perforator (prox LAD) was studied in 60 patients. Perfusion of the septum and anteroapical areas with thallium-201 injected during exercise was compared to results of coronary arteriography. Septal MPI defect was found in 92.3% of patients with obstruction of the proximal LAD, 27.7% of patients with obstruction of LAD distal to first septal perforator, 0% in patients with obstructions involving right or circumflex arteries, and in 10.5% of patients without coronary disease. Anteroapical MPI defects were found with similar frequency in the three groups with obstructive coronary disease. Septal MPI defect had a sensitivity of 92.3% and specificity of 85.4% in the diagnosis of proximal LAD disease. Normal septal perfusion with thallium-201 virtually excluded proximal LAD disease.

  9. Thallium-201 myocardial scintigraphy in patients with normal coronary arteries and normal left ventriculogram. Comparison with hemodynamic, metabolic and morphologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Loesse, B.; Kuhn, H.; Rafflenbeul, D.; Kroenert, H.; Hort, W.; Feinendegen, L.E.; Loogen, F.

    1980-01-01

    36 consecutive patients with chest pain and/or severe ventricular dysrhythmias, but normal coronary arteries and normal left ventriculogram, underwent thallium-201 myocardial imaging at rest and during exercise. The myocardial scintigram was abnormal in 27 patients (group A) and normal in only 9 patients (group B).

  10. Comparative study of body surface isopotential map, left ventriculogram and thallium-201 myocardial scintigram in patients with old lateral myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Naoyuki

    1988-01-01

    In 16 patients with old lateral myocardial infarction, body surface isopotential maps and 12 lead electrocardiograms were compared with left ventriculographic findings. In addition 8 of these subjects were performed thallium-201 myocardial scintigraphy in order to determine the location and extent of myocardial necrosis. Common 12 lead electrocardiographic findings of the subjects were initial Q waves more than 30 msec and inverted T waves in only aVL lead. The patients were classified into 4 groups according to the location and extent of ventricular wall motion abnormalities group I (6 cases) showed hypokinesis in the anterior segment, group II (5 cases): akinesis in the anterior segment and hypokinesis in the seg. 6, group III (4 cases): hypokinesis in the anterior segment and seg. 7, group IV (1 case): hypokinesis in the anterior segment and seg. 4, 7. And each of the 4 groups demonstrated characteristic findings of surface isopotential maps. Group II with coexisting hypokinesis in the seg. 6 showed surface isopotential maps additional pattern of anterior myocardial infarction, and group III with coexisting hypokinesis in the seg. 7 showed additional patterns of posterior myocardial infarction. The classification according to the abnormality of ventricular wall motion was also conformed with the thallium-201 myocardial scintigraphic findings except one case. These results suggest that body surface isopotential map is more useful than the 12 lead electrocardiogram in detecting the location and extent of left ventricular wall motion abnormality in patients with old lateral myocardial infarction. (author) 53 refs.

  11. Significance of exercise-induced ST segment depression in patients with myocardial infarction involving the left circumflex artery. Evaluation by exercise thallium-201 myocardial single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Koitabashi, Norimichi; Toyama, Takuji; Hoshizaki, Hiroshi [Gunma Prefectural Cardiovascular Center, Maebashi (Japan)] [and others

    2000-04-01

    The significance of exercise-induced ST segment depression in patients with left circumflex artery involvement was investigated by comparing exercise electrocardiography with exercise thallium-201 single photon emission computed tomography (Tl-SPECT) and the wall motion estimated by left ventriculography. Tl-SPECT and exercise electrocardiography were simultaneously performed in 51 patients with left circumflex artery involvement (angina pectoris 30, myocardial infarction 21). In patients with myocardial infarction, exercise-induced ST depression was frequently found in the V{sub 2}, V{sub 3} and V{sub 4} leads. In patients with angina pectoris, ST depression was frequently found in the II, III, aV{sub F}, V{sub 5} and V{sub 6} leads. There was no obvious difference in the leads of ST depression in patients with myocardial infarction with ischemia and without ischemia on Tl-SPECT images. In patients with myocardial infarction, the lateral wall motion of the infarcted area evaluated by left ventriculography was more significantly impaired in the patients with ST depression than without ST depression (p<0.01). Exercise-induced ST depression in the precordial leads possibly reflects wall motion abnormality rather than ischemia in the lateral infarcted myocardium. (author)

  12. Sequential dual-isotope SPECT imaging with thallium-201 and technetium-99m-sestamibi.

    Science.gov (United States)

    Heo, J; Wolmer, I; Kegel, J; Iskandrian, A S

    1994-04-01

    This study examined the results of sequential SPECT dual-isotope imaging with 201Tl and 99mTc-sestamibi in 148 patients, 114 of whom also had coronary angiography and 34 had exercise testing or adenosine infusion at a rate of 140 micrograms/kg/min for 6 min. The study was completed within 2 hr. The stress and rest images were normal in 11 of 17 patients (65%) with no CAD by angiography and in 33 of 34 patients with a low pretest probability of CAD (normalcy rate = 97%). The images were abnormal in 75 patients with CAD (77%). The perfusion pattern was compared to wall motion in 485 segments (97 patients) assessed by contrast ventriculography. There were no or reversible perfusion defects in 357 of 386 segments (92%) with no wall motion abnormality. Sequential dual-isotope imaging is feasible and can be completed in a short period of time and may therefore enhance laboratory throughput and patient convenience.

  13. Iodine-123 phenylpentadecanoic acid and single photon emission computed tomography in identifying left ventricular regional metabolic abnormalities in patients with coronary heart disease: comparison with thallium-201 myocardial tomography.

    Science.gov (United States)

    Hansen, C L; Corbett, J R; Pippin, J J; Jansen, D E; Kulkarni, P V; Ugolini, V; Henderson, E; Akers, M; Buja, L M; Parkey, R W

    1988-07-01

    Iodine-123 phenylpentadecanoic acid (IPPA) is a synthetic long chain fatty acid with myocardial kinetics similar to palmitate. Two hypotheses were tested in this study. The first hypothesis was that IPPA imaging with single photon emission computed tomography (SPECT) is useful in the identification of patients with coronary artery disease. Fourteen normal volunteers (aged 27 +/- 2 years) and 33 patients (aged 54 +/- 11 years) with stable symptomatic coronary artery disease and at least one major coronary artery with luminal diameter narrowing greater than or equal to 70% were studied with symptom-limited maximal exercise testing. The IPPA (6 to 8 mCi) was injected 1 min before the termination of exercise, and tomographic imaging was performed beginning at 9 min and repeated at 40 min after the injection of IPPA. Nine of the normal volunteers and 13 of the patients had a second examination performed at rest on another day. Using the limits of normal as 2 SD from the normal mean values, 27 of the 33 patients with coronary artery disease demonstrated abnormalities in either the initial distribution or the clearance of IPPA, or both. Nineteen of the 33 patients had a maximal variation of activity distribution of greater than or equal to 25% on the 9 min IPPA images. Twenty-two of the 33 patients had a maximal variation in IPPA washout greater than 17% and 17 had a washout rate less than or equal to 2%. There was good agreement between the location of significant coronary artery stenoses and abnormalities in the initial distribution and clearance of IPPA. The second hypothesis tested was that IPPA imaging is as or more sensitive and, therefore, complementary to thallium-201 imaging in the identification of exercise-induced ischemia in patients. Twenty-five of the 33 patients underwent both thallium-201 and IPPA tomographic imaging after symptom-limited maximal exercise testing. The amount of exercise performed by each patient during both studies was similar. Twenty

  14. Disease stage classification in hypertrophic cardiomyopathy by dual analysis of iodine-123-labeled metaiodobenzylguanidine and thallium-201 myocardial scintigraphies

    Energy Technology Data Exchange (ETDEWEB)

    Hiasa, Go [Ehime Univ., Matsuyama (Japan). School of Medicine

    2001-08-01

    Many patients with hypertrophic cardiomyopathy (HCM) gradually changes from typical myocardial hypertrophy to dilated cardiomyopathy-like features. However, it is difficult to estimate the disease stage in HCM. To determine the disease stage, dual analysis of iodine-123-labeled metaiodobenzylguanidine ({sup 123}I-MIBG) and thallium-201 ({sup 201}Tl) myocardial scintigraphies were performed in 108 HCM patients. According to the scintigraphic distribution patterns, patients were divided into three groups. Group A (n=15): normal distributions of both {sup 123}I-MIBG and {sup 201}Tl, group B (n=71): normal {sup 201}Tl and low {sup 123}I-MIBG patterns, group C (n=22): low distributions of both scintigraphies. The decrease in {sup 201}Tl uptake was observed in only group C. Concerning {sup 123}I-MIBG, heart-to-mediastinum ratio (H/M) and washout rate (WOR) had good correlations with left ventricular systolic functions. H/M was decreased and WOR was increased in order of C, B and A groups. Left ventricular diastolic function reflected by isovolumic relaxation time was longer in group B than in group A. Attenuated left ventricular hypertrophy, enlarged left ventricular volumes, impaired left ventricular functions and serious clinical symptoms were observed in only group C. Myocardial sympathetic abnormalities in group B may be mainly due to myocardial hypertrophy, and those in group C may be due to myocardial injury. Dual analysis of {sup 123}I-MIBG and {sup 201}Tl scintigraphies may be useful to classify disease stages of HCM. (author)

  15. Myocardial infarction diagnosis with body surface potential mapping, electrocardiography, vectorcardiography and thallium-201 scintigraphy: a correlative study with left ventriculography.

    Science.gov (United States)

    Ackaoui, A; Nadeau, R; Sestier, F; Savard, P; Primeau, R; Lemieux, R; Descary, M C

    1985-01-01

    In 35 subjects with typical or atypical angina and/or documented myocardial infarction (MI), body surface potential maps (BSPMs), ECG, VCG and rest Thallium-201 (T1-201) have been compared to left ventriculography (LVG). BSPMs were recorded with 26 ECGs, and BSPM abnormalities for MI cases were considered to be areas of normally positive potentials that have become negative. Subjects with MI were classified according to the segmental localization and degree of asynergy on LVG. Moderate anterolateral and apical asynergy were found to correlate with BSPM diagnosis of anterolateral MI and ischemia, severe anterolateral and apical asynergy with BSPM diagnosis of anterolateral MI and ischemia, and moderate diaphragmatic and/or posterobasal asynergy with BSPM diagnosis of posterior MI. Simultaneous anterior and posterior asynergy were found for BSPM diagnosis of anterior with posterior MI. Subjects with no LVG asynergy had normal BSPMs. BSPM diagnosis had the highest correlation coefficient with the LVG diagnosis (r = 0.88). ECG and VCG showed similar results with r = 0.65 and 0.71 respectively, while T1-201 had r = 0.55. The examination of our BSPMs, as well as the ECG, VCG and T1-201, did not permit to detect apical damage in presence of anterior MI, and posterobasal damage in the presence of inferoposterior MI. It is concluded that BSPMs are slightly superior to ECG and VCG for diagnosis of MI.

  16. Pentoxifylline (Trental) does not inhibit dipyridamole-induced coronary hyperemia: Implications for dipyridamole-thallium-201 myocardial imaging

    Energy Technology Data Exchange (ETDEWEB)

    Brown, K.A.; Slinker, B.K. (Univ. of Vermont College of Medicine, Burlington (USA))

    1990-06-01

    Dipyridamole-thallium-201 imaging is often performed in patients unable to exercise because of peripheral vascular disease. Many of these patients are taking pentoxifylline (Trental), a methylxanthine derivative which may improve intermittent claudication. Whether pentoxifylline inhibits dipyridamole-induced coronary hyperemia like other methylxanthines such as theophylline and should be stopped prior to dipyridamole-thallium-201 imaging is unknown. Therefore, we studied the hyperemic response to dipyridamole in seven open-chest anesthetized dogs after pretreatment with either pentoxifylline (0, 7.5, or 15 mg/kg i.v.) or theophylline (3 mg/kg i.v.). Baseline circumflex coronary blood flows did not differ significantly among treatment groups. Dipyridamole significantly increased coronary blood flow before and after 7.5 or 15 mm/kg i.v. pentoxifylline (p less than 0.002). Neither dose of pentoxifylline significantly decreased the dipyridamole-induced hyperemia, while peak coronary blood flow was significantly lower after theophylline (p less than 0.01). We conclude that pentoxyifylline does not inhibit dipyridamole-induced coronary hyperemia even at high doses.

  17. Myocardial scintigraphy with iodine-123 phenylpentadecanoic acid and thallium-201 in patients with coronary artery disease: A comparative dual-isotope study

    Energy Technology Data Exchange (ETDEWEB)

    Zimmermann, R.; Rauch, B.; Kapp, M.; Neumann, F.J.; Seitz, F.; Kuebler, W. (Heidelberg Univ. (Germany). Dept. of Cardiology); Bubeck, B. (Heidelberg Univ. (Germany). Dept. of Nuclear Medicine); Mall, G. (Heidelberg Univ. (Germany). Dept. of Pathology); Tillmanns, H. (Giessen Univ. (Germany). Dept. of Cardiology); Stokstad, P.

    1992-11-01

    To characterise the clinical usefulness of serial myocardial scintigraphy with iodine-123 phenylpentadecanoic acid (IPPA) in comparison with thallium-201, dual-isotope investigations were performed in 41 patients with angiographically documented coronary artery disease. Both tracers were adminstered simultaneously during symptom-limited ergometry. Planar scintigrams were acquired immediately after stress, and delayed imaging was performed after 1 h for IPPA and 4 h for {sup 201}Tl. Scintigrams were evaluated both qualitatively and quantitatively using a newly developed algorithm for automated image superposition. Initial myocardial uptake of both tracers was closely correlated (r=0.75, p<0.001). Both tracers also revealed a similar sensitivity for the identification of individual coronary artery stenoses {>=}75% (IPPA: 70%, {sup 201}Tl: 66.3%, P=NS) with identical specificity (69.8%). The number of persistent defects, however, was significantly higher with IPPA (P=0.021), suggesting that visual analysis of serial IPPA scintigrams may overestimate the presence of myocardial scar tissue. On the other hand, previous Q wave myocardial infarction was associated with a decreased regional IPPA clearance (29%{+-}11% vs 44%{+-}11% in normal myocardium, P<0.05). The data indicate that serial myocardial scintigraphy with IPPA is essentially as sensitive as scintigraphy with {sup 201}Tl for the detection of stress-induced perfusion abnormalities. Quantitative analysis of myocardial IPPA kinetics, however, is required for the evaluation of tissue viability. (orig.).

  18. Myocardial scintigraphy with iodine-123 phenylpentadecanoic acid and thallium-201 in patients with coronary artery disease: a comparative dual-isotope study.

    Science.gov (United States)

    Zimmermann, R; Rauch, B; Kapp, M; Bubeck, B; Neumann, F J; Seitz, F; Stokstad, P; Mall, G; Tillmanns, H; Kübler, W

    1992-01-01

    To characterise the clinical usefulness of serial myocardial scintigraphy with iodine-123 phenylpentadecanoic acid (IPPA) in comparison with thallium-201, dual-isotope investigations were performed in 41 patients with angiographically documented coronary artery disease. Both tracers were administered simultaneously during symptom-limited ergometry. Planar scintigrams were acquired immediately after stress, and delayed imaging was performed after 1 h for IPPA and 4 h for 201Tl. Scintigrams were evaluated both qualitatively and quantitatively using a newly developed algorithm for automated image superposition. Initial myocardial uptake of both tracers was closely correlated (r = 0.75, p or = 75% (IP-PA: 70.0%, 201Tl: 66.3%, P = NS) with identical specificity (69.8%). The number of persistent defects, however, was significantly higher with IPPA (P = 0.021), suggesting that visual analysis of serial IPPA scintigrams may overestimate the presence of myocardial scar tissue. On the other hand, previous Q wave myocardial infarction was associated with a decreased regional IPPA clearance (29% +/- 11% vs 44% +/- 11% in normal myocardium, P IPPA is essentially as sensitive as scintigraphy with 201Tl for the detection of stress-induced perfusion abnormalities. Quantitative analysis of myocardial IPPA kinetics, however, is required for the evaluation of tissue viability.

  19. Usefulness of thallium-201 myocardial scintigraphy during hyperventilation and accelerated exercise test in patients with vasospastic angina and nearly normal coronary artery

    Energy Technology Data Exchange (ETDEWEB)

    Sueda, Shozo; Mineoi, Kazuaki; Kondou, Tadashi [Takanoko Hospital, Matsuyama, Ehime (Japan)] [and others

    1998-04-01

    The usefulness of thallium-201 ({sup 201}Tl) myocardial scintigraphy was studied in 109 patients with vasospastic angina who had nearly normal coronary arteries (degree of stenosis <50%). Coronary spasm was confirmed by pharmacologic agents in all 109 patients from January 1991 to June 1996. The appearance rate of visual redistribution on {sup 201}Tl myocardial scintigraphy was compared between four groups, 34 patients performing graded bicycle ergometer exercise starting at a work load of 50 W with increments of 25 W every 3 min (Ergo(3) group), 14 patients performing hyperventilation for 5 min (HV(5) group), 31 patients performing bicycle ergometer exercise with increments of 25 W every 1 min after 5 min hyperventilation (HV(5)+Ergo(1) group), and 30 patients at rest (Rest group). The value of the visual redistribution rate on {sup 201}Tl myocardial scintigrams in the HV(5)+Ergo(l) group (65%) was higher than that in the patients of other groups (Ergo(3) 41%, HV(5) 43%, Rest 33%). However, there were no significant differences between the four groups. Stress {sup 201}Tl imaging after hyperventilation and accelerated exercise is useful to disclose ischemic evidence in about two thirds of patients with vasospastic angina and nearly normal coronary arteries, whereas about 40% of patients had visual redistribution on {sup 201}Tl myocardial scintigrams by performing standard procedures. (author)

  20. Serial thallium-201 imaging at rest in patients with unstable and stable angina pectoris: relationship of myocardial perfusion at rest to presenting clinical syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Brown, K.A.; Okada, R.D.; Boucher, C.A.; Phillips, H.R.; Strauss, H.W.; Pohost, G.M.

    1983-07-01

    In order to determine whether there are differences in myocardial perfusion at rest among patients with various unstable and stable angina syndromes, serial thallium-201 imaging was performed at rest in 19 patients presenting with rapidly worsening exertional angina (unstable angina, group A), 12 patients with rest angina alone without exertional symptoms (unstable angina, group B), and 34 patients with chronic stable angina. No patient had an episode of angina within 4 hours of study. Nineteen of 19 (100%) patients in group A demonstrated transient defects compared to only 3 of 12 (25%) patients in group B (p less than 0.0001) and 4 of 34 (12%) stable angina patients (p less than 0.0001). The majority of zones demonstrating transient defects in group A were associated with hypokinesis of the corresponding left ventriculogram segment without associated ECG evidence of previous infarction. There were no significant differences in the frequency of persistent thallium defects, severity of angiographic coronary artery disease, or frequency of regional wall motion abnormalities of myocardial segments supplied by stenotic coronary arteries among the three groups of patients. Transient defects have been shown to reflect reduction in regional coronary blood flow to viable myocardium. Therefore, we conclude that regional resting hypoperfusion of viable myocardium is far more common in patients with exertional unstable angina symptoms than in patients with rest angina alone or chronic stable angina.

  1. Assessment of myocardial viability by exercise stress-redistribution myocardial scintigraphy with thallium-201; The usefulness of C-map

    Energy Technology Data Exchange (ETDEWEB)

    Narita, Michihiro; Kurihara, Tadashi; Murano, Kenichi; Usami, Masahisa (Sumitomo Hospital, Osaka (Japan))

    1993-09-01

    This study was intended to clarify whether Tl-201 washout rate abnormality after exercise stress can detect myocardial viability in the myocardium with perfusion defect on redistribution (RD) images. The subjects were 29 patients with ischemic heart disease in whom perfusion defect was seen on delayed (3 hr) RD images and had percutaneous transluminal coronary angioplasty (PTCA). A combined map (C-map) was prepared by adding the location of washout rate abnormality ([<=]30%) to perfusion defect on RD images before PTCA. The C-map and myocardial images after PTCA (Post-map) were compared. The left ventriculogram was divided into 17 segments. C-map and Post-map were qualitatively concordant with each other in 27 of 29 patients (93%). In the other 2 patients, only one segment showed discordance of findings between the two maps. Out of 152 segments with perfusion defect on RD images, 75 segments (50%) showed normal perfusion in both the C-map and the Post-map. In segmental analysis, the C-map and the Post-map were found consistent in 80% of the cases. In 12 patients with fixed defect before PTCA, the agreement between the C-map and the Post-map was also excellent (86%). The present C-map was useful for not only qualitative but also quantitative analyses of myocardial viability in myocardial segments which show perfusion defect on standard RD images. (N.K.).

  2. Assessment of myocardial viability by dynamic tomographic iodine 123 iodophenylpentadecanoic acid imaging: comparison with rest-redistribution thallium 201 imaging.

    Science.gov (United States)

    Iskandrian, A S; Powers, J; Cave, V; Wasserleben, V; Cassell, D; Heo, J

    1995-01-01

    This study examined the ability of dynamic 123I-labeled iodophenylpentadecanoic acid (IPPA) imaging to detect myocardial viability in patients with left ventricular (LV) dysfunction caused by coronary artery disease. Serial 180-degree single-photon emission computed tomographic (SPECT) images (five sets, 8 minutes each) were obtained starting 4 minutes after injection of 2 to 6 mCi 123I at rest in 21 patients with LV dysfunction (ejection fraction [EF] 34% +/- 11%). The segmental uptake was compared with that of rest-redistribution 201Tl images (20 segments/study). The number of perfusion defects (reversible and fixed) was similar by IPPA and thallium (11 +/- 5 vs 10 +/- 5 segments/patient; difference not significant). There was agreement between IPPA and thallium for presence or absence (kappa = 0.78 +/- 0.03) and nature (reversible, mild fixed, or severe fixed) of perfusion defects (kappa = 0.54 +/- 0.04). However, there were more reversible IPPA defects than reversible thallium defects (7 +/- 4 vs 3 +/- 4 segments/patient; p = 0.001). In 14 patients the EF (by gated pool imaging) improved after coronary revascularization from 33% +/- 11% to 39% +/- 12% (p = 0.002). The number of reversible IPPA defects was greater in the seven patients who had improvement in EF than in the patients without such improvement (10 +/- 4 vs 5 +/- 4 segments/patient; p = 0.075). 123I-labeled IPPA SPECT imaging is a promising new technique for assessment of viability. Reversible defects predict recovery of LV dysfunction after coronary revascularization.

  3. A comparison of the clinical relevance of thallium201 and ...

    African Journals Online (AJOL)

    Thallium-201 is at present the radiotracer of choice for the clinical evaluation of myocardial blood flow. Although different technetium-99m-isonitrile agents have been synthesised recently, only 99mTc-melhoxyisobutyl-isonitrile (99mTc_MIBI) has proved to hold promise for clinical implementation. The myocardial distribution ...

  4. Usefulness and limitations of thallium-201 myocardial scintigraphy in delineating location and size of prior myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Niess, G.S.; Logic, J.R.; Russell, R.O. Jr.; Rackley, C.E.; Rogers, W.J.

    1979-05-01

    Thirty-two patients were evaluated at a mean of 7 +- 2 months after infarction with a 12-lead ECG, resting /sup 201/Tl myocardial scintigram, biplane left ventriculogram, and coronary angiograms. From the left ventriculogram, asynergy was quantified as percent abnormally contracting segment (% ACS), the percent of end-diastolic circumference which was either akinetic or dyskinetic. Using a computerized planimetry system, we expressed /sup 201/Tl perfusion defects as a percentage of total potential thallium uptake. Of 21 patients with ECG evidence of prior transmural infarction, a /sup 201/Tl defect was present in 20, and angiographic asynergy was present in all 21. The site of prior infarction by ECG agreed with the /sup 201/T1 defect location in 24 of 32 patients and with site of angiographic asynergy in 23 of 32 patients. Scintigraphic defects were present in only four of 10 patients with ACS less than or equal to 6%, but scintigraphic defects were found in 20 of 22 patients with ACS > 6%. Thallium defect size correlated marginally with angiographic left ventricular ejection fraction but correlated closely with angiographic % ACS. Thallium defect size was similar among patients with one-, two-, or three-vessel coronary artery disease (greater than or equal to 70% stenosis), but thallium defect size was larger in patients with electrocardiographic evidence of transmural infarction or pulmonary capillary wedge pressure > 12 mm Hg. Thus, resting /sup 201/T1 myocardial scintigraphy is useful in localizing and quantifying the extent of prior myocardial infarction, but is insensitive to small infarcts (ACS < 6%).

  5. Thallium-201 is comparable to technetium-99m-sestamibi for estimating cardiac function in patients with abnormal myocardial perfusion imaging

    Directory of Open Access Journals (Sweden)

    Ming-Che Wu

    2015-11-01

    Full Text Available We analyzed the left-ventricular functional data obtained by cardiac-gated single-photon emission computed tomography myocardial perfusion imaging (MPI with thallium-201 (Tl-201 and technetium-99m-sestamibi (MIBI protocols in different groups of patients, and compared the data between Tl-201 and MIBI. Two hundred and seventy-two patients undergoing dipyridamole stress/redistribution Tl-201 MPI and 563 patients undergoing 1-day rest/dipyridamole stress MIBI MPI were included. Higher mean stress ejection fraction (EF, rest EF, and change in EF (ΔEF were noticed in the normal MPI groups by both Tl-201 and MIBI protocols. Higher mean EF was observed in the females with normal MPI results despite their higher mean age. Comparisons between the Tl-201 and MIBI groups suggested a significant difference in all functional parameters, except for the rest end diastolic volume/end systolic volume and ΔEF between groups with negative MPI results. For the positive MPI groups, there was no significant difference in all parameters, except for the change in end diastolic volume and change in end systolic volume after stress between both protocols. The Tl-201 provides comparable left-ventricular functional data to MIBI cardiac-gated single-photon emission computed tomography in patients with positive MPI results, and may therefore be undertaken routinely for incremental functional information that is especially valuable to this patient group.

  6. Simultaneous dual myocardial imaging with iodine-123-[beta]-methyl iodophenyl-pentadecanoic acid (BMIPP) and thallium-201 in patients with coronary heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Tawarahara, Kei; Kurata, Chinori; Taguchi, Takahisa; Aoshima, Shigeyuki; Okayama, Kenichi; Kobayashi, Akira; Yamazaki, Noboru; Kaneko, Masao (Hamamatsu Univ. School of Medicine, Shizuoka (Japan))

    1994-02-01

    To assess the clinical value of simultaneous dual myocardial imaging with iodine-123-[beta]-methyl-iodophenyl-pentadecanoic acid ([sup 123]I-BMIPP) and thallium-201 ([sup 201]TL), myocardial imaging was performed at rest and during execise in seven patients with coronary heart disease. When [sup 123]I-BMIPP and [sup 201]Tl images were compared, the initial exercise and resting images agreed 87% and 64%, respectively. In the initial resting images, the regional uptake of [sup 123]I-BMIPP was frequently less than that of [sup 201]Tl. The incidence of exercise-induced reversible defects by [sup 201]Tl in the Tl>BMIPP regions was significantly higher than that in the Tl=BMIPP regions (57% vs 4%, p<0.01) and the incidence of coronary narrowing of more than 90% in the Tl>BMIPP regions was also significantly higher than that in the Tl=BMIPP regions (91% vs 38%, p<0.01). In addition, this disparity (Tl>BMIPP) was found more frequently in regions with abnormal wall motion than in regions with normal wall motion (hypokinetic regions; 68%, severe hypokinetic or akinetic regions; 50%, vs normokinetic regions; 4%, p<0.01). In contrast, the uptake of [sup 123]I-BMIPP correlated closely with that of [sup 201]Tl in normal myocardium and the uptake of both [sup 123]I-BMIPP and [sup 201]Tl was severely reduced in myocardium with severe ischemia during exercise and prior infarction. These results indicate that dual myocardial imaging with [sup 123]I-BMIPP and [sup 201]Tl may provide a unique means of identifying patients with metabolically disturbed myocardium, such as hibernating and stunned myocardium. (author).

  7. Evaluation of myocardial flow reserve using pharmacological stress thallium-201 single-photon emission computed tomography: is there a difference between total arterial off-pump coronary artery bypass grafting and conventional coronary artery bypass grafting?

    Science.gov (United States)

    Lee, Jae Won; Ryu, Sang Wan; Song, Hyun; Kim, Kyung Sun; Yang, Yu Jung; Moon, Dae Hyeuk

    2004-01-01

    The advantage of total arterial off-pump coronary bypass grafting (OPCAB) over conventional onpump coronary artery bypass grafting with 1 internal thoracic artery and veins (CCAB) in terms of myocardial flow reserve has not been studied. We studied these procedures using thallium- 201 perfusion single-photon emission computed tomography (Tl-201 perfusion SPECT). Between 1997 and 2001, 152 patients were recruited from our database (OPCAB, n = 100; CCAB, n = 52). All patients underwent pharmacological stress Tl-201 perfusion SPECT 3 to 12 months after bypass surgery. Myocardial perfusion was analyzed semiquantitatively with a 5-point scoring system in a 20-segment model (0, normal, to 4, absence of uptake). Summed stress (SSS), rest (SRS), and difference score (SDS) of the entire myocardium as well as average scores (ASS, ARS, ADS) of individual walls (anterior, septal, lateral, and inferior) were compared by Student t test as well as by repeated-measures analysis of variance with Bonferroni correction. The SSS, SRS, and SDS of OPCAB versus those of CCAB were 6.86 +/- 0.72 versus 7.17 +/- 0.92, 3.95 +/- 0.57 versus 3.75 +/- 0.73, and 2.91 +/- 0.47 versus 3.42 +/- 0.74 (P > .05). However, the lateral wall showed lower scores in OPCAB (ASS, 0.18 versus 0.41, P = .015; ARS, 0.12 versus 0.20, P = .168; ADS, 0.06 versus 0.21, P = .031). The septal wall had higher scores in OPCAB (ASS, 0.33 versus 0.12, P = .003; ARS, 0.18 versus 0.07, P = .037; ADS, 0.14 versus 0.04, P = .030). The anterior and inferior walls were not different between the 2 groups. OPCAB led to results similar to those of CCAB. The better results in the lateral wall have been the effect of grafting radial artery rather than vein. The similarity in myocardial reserve in the inferior wall between the 2 groups needs further study. There was no deleterious effect of off-pump as opposed to on-pump CAB.

  8. Kinetic analysis of 18F-fluorodihydrorotenone as a deposited myocardial flow tracer: Comparison to thallium-201.

    Energy Technology Data Exchange (ETDEWEB)

    Marshall, Robert C.; Powers-Risius, Patricia; Reutter, Bryan W.; O' Neil, James P.; La Belle, Michael; Huesman, Ronald H.; VanBrocklin, Henry F.

    2004-03-01

    The goal of this investigation was to assess the accuracy of 18F-fluorodihydrorotenone (18F-FDHR) as a new deposited myocardial flow tracer and compare the results to those for 201Tl. Methods. The kinetics of these flow tracers were evaluated in 22 isolated, erythrocyte- and albumin-perfused rabbit hearts over a flow range encountered in patients. The two flow tracers plus a vascular reference tracer (131I-albumin) were introduced as a bolus through a port just above the aortic cannula. Myocardial extraction, retention, washout, and uptake parameters were computed from the venous outflow curves using the multiple indicator dilution technique and spectral analysis. Results. The mean initial extraction fractions of 18F-FDHR (0.85 +- 0.07) and 201Tl (0.87 +- 0.05) were not significantly different, although the initial extraction fraction for 18F-FDHR declined with flow (P < 0.0001), whereas the initial extraction fraction of 201Tl did not. Washout of 201Tl was faster (P < 0.001) and more affected by flow (P < 0.05) than 18F-FDHR washout. Except for initial extraction fraction, 18F-FDHR retention was greater (P < 0.001) and less affected by flow (P < 0.05) than 201Tl retention. Reflecting its superior retention, net uptake of 18F-FDHR was better correlated with flow than 201Tl uptake at both one and fifteen minutes after tracer introduction (P < 0.0001 for both comparisons). Conclusion. The superior correlation of 18F-FDHR uptake with flow indicates that it is a better flow tracer than 201Tl in the isolated rabbit heart. Compared to the other currently available positron-emitting flow tracers (82Rb, 13N-ammonia, and 15O-water), 18F-FDHR has the potential of providing excellent image resolution without the need for an on-site cyclotron.

  9. Exercise-induced U-wave changes in patients with coronary artery disease. Correlation with tomographic thallium-201 myocardial imaging

    Energy Technology Data Exchange (ETDEWEB)

    Miyakoda, Hiroyuki; Endo, Akihiro; Kato, Masahiko; Kato, Tatsuo; Omodani, Hiroki; Osaki, Shuichi; Kinugawa, Toru; Hoshio, Akira [Tottori Univ., Yonago (Japan). School of Medicine; Mashiba, Hiroto

    1996-09-01

    We studied the relation between exercise-induced U-wave changes and the site of a reversible defect in tomographic {sup 201}Tl myocardial imaging. Coronary artery disease and control groups consisted of 116 and 42 patients, respectively. In the anteroapical-ischemia group (n=37), the sensitivity of U-wave inversion in the anterior precordial leads for ischemia was 62% (23/37) and that of prominent U-waves without an increase in the height of the T-wave in the inferior limb leads was 57% (21/37). In this group, 18 patients (49%) met both criteria (18 =78%= of 23 patients with the former; 18 =86%= of 21 patients with the latter). In the posterior-ischemia group (n=59), the sensitivity of prominent U-waves with a decrease in the height of the T-wave in the anterior precordial leads for ischemia was 63% (37/59) and that of U-wave inversion in the inferior limb leads was 20% (12/59). In this group, 12 patients (20%) met both criteria (12 =32%= of 37 patients with the former; all 12 patients with the latter). The specificity of U-wave criteria was 100%. In the anteroapical and posterior-ischemia group (n=20), the sensitivity of U-wave criteria for anteroapical and posterior ischemia was 85% (17/20) and 40% (8/20), respectively. In conclusion, U-wave criteria are not only specific but also sensitive for myocardial ischemia determined by {sup 201}Tl imaging. (author)

  10. Comparison of I-123 IPPA and thallium-201 for the prediction of functional improvement after myocardial revascularization

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, C.L.; Van Decker, W.; Iskandrian, A.S. [Temple Univ. Hospital, Allegheny Univ. of the Health Sciences, Philadelphia, PA (United States)

    1998-12-31

    Sixteen patients in the phase I/II study of IPPA had RRT prior to MR. Patients were injected with 2-6 mCi of IPPA; sequential SPECT imaging was begun at 4 minutes. Radionuclide ventriculography was performed before and 8 weeks after MR. The ability of IPPA and RRT to identify patients with a 5% increase in EF after MR were compared using receiver operating characteristic (ROC) curve analysis. The IPPA images were analyzed using two techniques: The first method looked at the fraction of the myocardium (FM) demonstrating abnormal metabolism and the second at the FM demonstrating descreased initial perfusion and abnormal metabolism. RRT images were analyzed three different ways: Thresholded uptake on the initial images, thresholded uptake on the delayed images and relative improvement between the initial and delayed images. The parameters giving the highest ROC areas were identified for both IPPA and RRT and then compared. Five patients underwent PTCA and 11 underwent coronary artery bypass grafting. The mean EF increased from 36{+-}12% to 41{+-}14% after MR (p=0.012). The amount of myocardium (AM) showing intermediate metabolism (IM) of IPPA from 0.001 to 0.013 In counts/min was a strong predictor of FI after MR (area=0.92{+-}0.05). The AM that was hypoperfused and had IM (activity<90% of maximum uptake and metabolism from 0.002-0.013 In counts/min) was a stronger predictor (area=0.97 0.03). Using RRT, the best predictor was the AM with greater than 55% of maximal activity on the initial images (area=0.83{+-}0.10); the AM>45% of maximal activity on the delayed images was slightly lower (area=0.81{+-}0.10); improvement between the initial and delayed images was comparatively weak (0.56{+-}0.13). The difference between the areas between IPPA and RRT, however, was not statistically significant. (orig./MG) [Deutsch] Sechzehn Patienten der Phase-I/II-IPPA-Studie wurden einer RRT vor MR unterzogen. Es wurden 75-220 MBq IPPA injiziert und 4 min p.i. eine sequentielle SPECT

  11. Protocols of myocardial perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seong Min [College of Medicine, Chungnam National University, Daejeon (Korea, Republic of)

    2005-02-15

    In myocardial perfusion scintigraphy, the results of this evaluation now confront the practitioner of nuclear medicine with methodological options. Most nuclear cardiologic studies are performed using thallium-201, Tc-99m sestamibi and Tc-99m tertrofosmin. Some part of these studies use some form of pharmacologic stress test. While tailoring each test to the individual is ideal, this may be impractical for a busy department. Accordingly, established protocols to be used for patients with similar clinical presentations will be helpful. The following review presents methodology of various imaging protocols mainly according to the guidelines of nuclear cardiology procedures in American Society of Nuclear Cardiology.

  12. Leg {sup 201}Tl-SPECT in chronic exertional compartment syndrome; Tomoscintigraphie des jambes au thallium 201 dans le diagnostic du syndrome de loge chronique

    Energy Technology Data Exchange (ETDEWEB)

    Elkadri, N.; Slim, I.; Blondet, C.; Choquet, Ph.; Constantinesco, A. [Hopital Hautepierre, Service de Biophysique et Medecine Nucleaire, 67 - Strasbourg (France); Lecocq, J. [Hopital Hautepierre, Service de Medecine Physique et Readaptation, 67 - Strasbourg (France)

    2004-06-01

    Leg {sup 201}Tl-SPECT in chronic exertional compartment syndrome Background: The chronic exertional compartment syndrome is one of the most frequent origins regarding leg pain due to sport training. The diagnosis can be established by invasive compartment pressure measurement. The aim of this study is to evaluate the role that could have {sup 201}Tl-SPECT for patients with suspicion of compartment syndrome. Patients and methods: 51 leg {sup 201}Tl-SPECT exams were performed (exercise - and rest without reinjection) in 49 patients; 28 had compartment syndrome confirmed by pressure measurement. About 100 MBq of {sup 201}Tl were injected during exercise, when pain appeared or at least after 25 minutes exercise. We studied mean percentages of level uptake for each compartment, referred to the maximal uptake of both legs. Results: 47 compartments were concerned by compartment syndrome and 361 compartments were not. Scintigraphic patterns in compartments are reversible ischaemia (45%), uptake stability (36%) or reverse redistribution (19%); these patterns are not linked to compartment syndrome. However, there is a significant difference of rest {sup 201}Tl level uptake between compartments with and without compartment syndrome and a significant correlation between muscular pressure measurement and rest level uptake. Conclusion: {sup 201}Tl-SPECT shows that only ischaemia does not explain compartment syndrome. Moreover, it allows to predict pressure variation during exercise but it does not offer any interest in order to select patients for muscular invasive pressure measurement. (author)

  13. Thallium-201 scintigraphy in unstable angina pectoris

    Energy Technology Data Exchange (ETDEWEB)

    Wackers, F.J.T.; Lie, K.I.; Liem, K.L.; Sokole, E.B.; Samson, G.; Van Der Schoot, J.B.; Durrer, D.

    1978-04-01

    Thallium-201 scintigraphy was performed during the pain free period in 98 patients with unstable angina. Scintiscans were positive in 39 patients, questionable in 27 patients and normal in 32 patients. Eighty-one patients responded favorably to treatment (group I). Seventeen patients had complicated courses (group II) and despite maximal treatment with propranolol either developed infarction (six patients) or continued to have angina necessitating coronary surgery (11 patients). In group I during the pain free period 26 of 81 patients had positive thallium-201 scans, whereas 20 patients had an abnormal ECG at that time; during angina 18 patients had transient ECG changes. In group II during the pain free period 13 of 17 patients had positive scans, whereas two patients had abnormal ECG at that time; during angina 12 patients showed transient ECG changes. The sensitivity to recognize group II was 76% for thallium-201 scintigraphy, 11% for ECG during the pain free period; 70% for ECG during angina; 94% for the combination of either positive scans or abnormal ECG. Thus, positive thallium-201 scans occur in patients with unstable angina, positive scans can be obtained during the pain free period, thallium-201 scans are more frequently positive in patients with complicated course.

  14. Combined thallium-201 and dynamic iodine-123 iodophenylpentadecanoic acid single-photon emission computed tomography in patients after acute myocardial infarction with effective reperfusion.

    Science.gov (United States)

    Richter, W S; Beckmann, S; Cordes, M; Schuppenhauer, T; Schartl, M; Munz, D L

    2000-12-01

    Considerable derangements of energy metabolism are to be expected during ischemia and reperfusion. In ischemic myocardium, the oxidative degradation of carbohydrates is shifted toward the anaerobic production of lactate and the oxidation of fatty acids is suppressed. The aim of this study was to examine the uptake and metabolism of iodine-123 (123I) iodophenylpentadecanoic acid (IPPA) in stunned myocardium. In 15 patients, SPECT with 201Tl and 123I IPPA as well as echocardiography with low-dose dobutamine stimulation were performed 12 +/- 5 days after myocardial infarction with reperfusion. Follow-up echocardiography was carried out 24 +/- 8 days later for documentation of functional improvement. Uptake of 201Tl and 123I IPPA were obtained in five left ventricular segments, and dynamic SPECT imaging was used for calculation of the fast and the slow components of the biexponential myocardial 123I IPPA clearance. Wall motion improved in 14 of 26 dysfunctional segments (54%). Stunned segments were characterized by a reduced 123I IPPA extraction, a shorter half-life of the fast, and a longer half-life of the slow clearance component. All parameters of the combined 201Tl/123I IPPA study predicted functional recovery with similar accuracies (area under the receiver operator characteristic curves between 0.68 and 0.76; p = NS). Analysis of 201Tl uptake alone could not predict functional recovery in this study. Stunned myocardium is characterized by a disturbance of fatty acid metabolism. For prediction of functional improvement, 123I IPPA imaging added significant diagnostic information.

  15. Identification of advanced coronary artery disease with exercise myocardial perfusion imaging: the clinical value of a novel approach for assessing lung thallium-201 uptake

    Energy Technology Data Exchange (ETDEWEB)

    Moralidis, Efstratios [Hippokration Hospital, Nuclear Medicine Department, Thessaloniki (Greece); Hippokration Medical Center, Larissa (Greece); Spyridonidis, Tryfon [Hippokration Medical Center, Larissa (Greece); Arsos, Georgios [Hippokration Hospital, Nuclear Medicine Department, Thessaloniki (Greece); Anagnostopoulos, Constantinos [Royal Brompton Hospital, Nuclear Medicine Department, London (United Kingdom)

    2007-04-15

    The precise clinical utility of lung{sup 201}Tl uptake in exercise SPECT myocardial perfusion imaging remains open to research. This study validates an optimal index for lung{sup 201}Tl uptake measurement and assesses its value in the prediction of higher-risk coronary artery disease (CAD). Three hundred and ninety-eight patients underwent exercise SPECT myocardial perfusion imaging. They were separated into derivation (n = 217) and validation (n = 186) groups, both including sub-populations of lower- and higher-risk CAD, according to coronary angiography. Another 56 individuals with a low probability of CAD comprised the control group. From a planar, anterior, post-exercise acquisition, the lung (L) to heart (H) maximal (L/H{sub max}), total (L/H{sub mean}) and background-subtracted total (L/H{sub net}) ratios were calculated. These were also adjusted for confounding variables, as assessed from the control group. ROC analysis was used to compare the L/H ratios and define thresholds of abnormality. The performance of the optimal index was assessed in the derivation group and was then tested in the validation population. Subsequently, it was compared with other scintigraphic, exercise electrocardiography and clinical variables. In the derivation group L/H{sub net} was a better discriminator for higher-risk CAD than both L/H{sub max} and L/H{sub mean}. Similarly, the adjusted L/H{sub net} was a better discriminator than both the adjusted L/H{sub max} and the adjusted L/H{sub mean}. No significant difference was attained between L/H{sub net} and the adjusted L/H{sub net}. At the upper defined threshold of abnormality, sensitivity and specificity of L/H{sub net} in the detection of higher-risk CAD in the derivation and the validation cohorts were 52% and 92% versus 47% and 94%, respectively (p = ns). The results were similar at other defined thresholds. Moreover, L/H{sub net} was found to be a significant predictor of higher-risk CAD, superior to myocardial perfusion

  16. Clinical features and applications of thallium-201. With reference to scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Tadashige

    1988-12-01

    Thallium-201 is not only used widely in myocardial imaging but also has a great potential in other various nuclear medicine imaging studies. This paper presents clinical features and applications of thallium-201, focusing on clinical trials with thallium-201 at the Shinshu University School of Medicine. Thallium-201 myocardial scintigraphy offers information on (1) ventricular position and morphology, (2) hypertrophy or dilatation of the left ventricle, (3) hypertrophy or dilatation of the right ventricle, (4) site and extent of myocardial ischemia and infarct, (5) myocardial blood flow, (6) pulmonary congestion or interstitial pulmonary edema, and (7) pericardial effusion. It can be used in the following evaluation or diagnosis: (1) acute or old myocardial infarction, (2) angina pectoris, (3) treatment strategy or prognosis of ischemic heart disease, (4) treatment strategy or observation of bypass graft or drug therapy, (5) hypertrophic or dilated idiopathic cardiomyopathy, (6) myocardial lesions induced by sarcoidosis, collagen disease, and neuro-muscular disease, (7) ventricular hypertrophy and pulmonary edema, and (9) pericarditis, pericardial effusion, and systolic pericarditis associated with underlying disease. The significance of tumor, liver, bone marrow scintigraphies is also referred to. (Namekawa, K) 69 refs.

  17. Noninvasive quantification of myocardial perfusion heterogeneity by Markovian analysis in SPECT nuclear imaging; Quantification non invasive de l'heterogeneite de la perfusion du myocarde par analyse markovienne en imageries nucleaire SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Pons, G.

    2011-04-28

    Cardiovascular diseases are the leading cause of mortality worldwide, and third of these deaths are caused by coronary artery disease and rupture of vulnerable atherosclerotic plaques. The heterogeneous alteration of the coronary microcirculation is an early phenomenon associated with many cardiovascular risk factors that can strongly predict the subsequent development of coronary artery disease, and lead to the appearance of myocardial perfusion heterogeneity. Nuclear medicine allows the study of myocardial perfusion in clinical routine through scintigraphic scans performed after injection of a radioactive tracer of coronary blood flow. Analysis of scintigraphic perfusion images currently allows the detection of myocardial ischemia, but the ability of the technique to measure the perfusion heterogeneity in apparently normally perfused areas is unknown. The first part of this thesis focuses on a retrospective clinical study to determine the feasibility of myocardial perfusion heterogeneity quantification measured by Thallium-201 single photon emission computed tomography (SPECT) in diabetic patients compared with healthy subjects. The clinical study has demonstrated the ability of routine thallium-201 SPECT imaging to quantify greater myocardial perfusion heterogeneity in diabetic patients compared with normal subjects. The second part of this thesis tests the hypothesis that the myocardial perfusion heterogeneity could be quantified in small animal SPECT imaging by Thallium-201 and/or Technetium-99m-MIBI in an experimental study using two animal models of diabetes, and is correlated with histological changes. The lack of difference in myocardial perfusion heterogeneity between control and diabetic animals suggests that animal models are poorly suited, or that the technology currently available does not seem satisfactory to obtain similar results as the clinical study. (author)

  18. Biokinetics of radiolabeled Iodophenylpentadecanoic acid (I-123-IPPA) and thallium-201 in a rabbit model of chronic myocardial infarction measured using a series of thermoluminescent dosimeters

    Science.gov (United States)

    Medich, David Christopher

    1997-09-01

    The biokinetics of Iodophenylpentadecanoic acid (123I-IPPA) during a chronic period of myocardial infarction were determined and compared to 201Tl. IPPA was assessed as a perfusion and metabolic tracer in the scintigraphic diagnosis of coronary artery disease. The myocardial clearance kinetics were measured by placing a series of thermoluminescent dosimeters (TLDs) on normal and infarcted tissue to measure the local myocardial activity content over time. The arterial blood pool activity was fit to a bi-exponential function for 201Tl and a tri-exponential function for 123I-IPPA to estimate the left ventricle contribution to TLD response. At equilibrium, the blood pool contribution was estimated experimentally to be less than 5% of the total TLD response. The method was unable to resolve the initial uptake of the imaging agent due in part to the 2 minute TLD response integration time and in part to the 30 second lag time for the first TLD placement. A noticeable disparity was observed between the tracer concentrations of IPPA in normal and ischemic tissue of approximately 2:1. The fitting parameters (representing the biokinetic eigenvalue rate constants) were related to the fundamental rate constants of a recycling biokinetic model. The myocardial IPPA content within normal tissue was elevated after approximately 130 minutes post injection. This phenomenon was observed in all but one (950215) of the IPPA TLD kinetics curves.

  19. Effect of long-term cholesterol-lowering treatment with HMG-CoA reductase inhibitor (Simvastatin) of myocardial perfusion evaluated by thallium-201 single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Hosokawa, Ryohei; Nohara, Ryuji; Linxue, Li; Sasayama, Shigetake [Kyoto Univ. (Japan). Graduate School of Medicine; Tamaki, Shunichi; Hashimoto, Tetsuo; Tanaka, Masahiro; Miki, Shinji

    2000-03-01

    Fifteen patients with either angina pectoris or old myocardial infarction, who had positive {sup 201}Tl single photon emission computed tomography (SPECT) imaging and coronary sclerosis of more than 50%, were treated with an HMG-CoA reductase inhibitor (simvastatin) for more than 1 year. They were compared with an untreated control group (n=25). Total cholesterol decreased 22% and high-density lipoprotein (HDL) increased 9% with simvastatin; both changes were significantly different from those in controls. Long-term simvastatin induced improvement of myocardial perfusion on {sup 201}Tl SPECT images both during exercise and at rest, which was also significantly different from controls. In addition, the improvement of myocardial perfusion on {sup 201}Tl SPECT images was clearly related to the improvements in cholesterol values, especially nonHDL cholesterol. Thus, the greater the decrease in nonHDL cholesterol, the greater the improvement in myocardial perfusion at rest or during exercise with long-term treatment using an HMG-CoA reductase inhibitor. These findings indicate that the improvements in cholesterol values caused by HMG-CoA reductase inhibitor therapy are related to improvements of myocardial perfusion seen on {sup 201}Tl SPECT images. (author)

  20. Functional Significance of Angiographic Collaterals in Patients with Totally Occluded Right Coronary Artery: Intracoronary Thallium-201 Scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Yun; Lee, Jong Doo; Cho, Seung Yun; Shim, Won Heum; Ha, Jong Won; Kim, Han Soo; Kwon, Hyuk Moon; Jang, Yang Soo; Chung, Nam Sik; Kim, Sung Soon [Yonsei University College of Medicine, Seoul (Korea, Republic of); Park, Chang Yun; Kim, Young Soo [Inje University College of Medicine, Seoul (Korea, Republic of)

    1993-07-15

    To compare the myocardial viability in patients suffering from total occlusion of the right coronary artery (RCA) with the angiographic collaterals, intracoronary injection of Thallium-201 (T1-201) was done to 14 coronary artery disease (CAD) patients (pts) with total occlusion of RCA and into four normal subjects for control. All 14 CAD pts had Grade 2 or 3 collateral circulations. There were 14 male and 4 females, and their ages ranged from 31 to 70 years. In nine pts, T1-201 was injected into left main coronary artery (LCA) (300 approx 350 mu Ci) to evaluate the myocardial viability of RCA territory through collateral circulations. The remaining five pts received T1-201 into RCA (200-250 mu Ci) because two had intraarterial bridging collaterals and three had previous successful PTCA. Planar and SPECT myocardial perfusion images were obtained 30 minutes, and four to five hours after T1-201 reinjection. Intravenous T1-201 reinjection (six pts) or {sup 99m}Tc-MIBI (two pts) were also performed in eight CAD pts. Intracoronary myocardial perfusion images were compared with intravenous T1-201(IV T1-201) images, EGG, and ventriculography. Intracoronary TI-201 images proved to be superior to that of IV T1-201 due to better myocardial to background uptake ratio and more effective in the detection of viable tissue. We also found that perfusion defects were smaller on intracoronary T1-201 images than those on the IV T1-201. All of the 14 CAD pts had either mostly viable myocardium (seven pts) or large area of T1-201 perfusion (seven pts) in RCA territory, however ventriculographic wall motion and ECG did not correlate well with intracoronary myocardial perfusion images. In conclusion, total RCA occlusion patients with well developed collateral circulation had large area of viable myocardial in the corresponding territory.

  1. PET detection of viable tissue in myocardial segments with persistent defects at T1-201 SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Brunken, R.C.; Kottou, S.; Nienaber, C.A.; Schwaiger, M.; Ratib, O.M.; Phelps, M.E.; Schelbert, H.R.

    1989-07-01

    To assess myocardial glucose metabolism and perfusion in 142 myocardial segments with defects seen at thallium-201 single photon emission computed tomography (SPECT), 27 studies with positron emission tomography (PET) utilizing nitrogen-13 ammonia and fluorine-18 deoxyglucose were performed in 26 patients. Myocardial infarction was defined on the basis of concordant reductions in segmental perfusion and glucose utilization; myocardial ischemia, on the basis of preservation of glucose utilization (metabolic viability) in segments with hypoperfusion at rest. Of the 142 segments analyzed, 101 had fixed defects, 31 had partially reversible defects, and ten had completely reversible defects. Preserved glucose utilization was identified in 47 (46.5%) of the segments with fixed defects and 20 (64.5%) of the segments with partially reversible defects. Of the ten segments with completely reversible defects, five (50%) were normal, and five (50%) exhibited ischemia at PET. Visual improvement in a persistent thallium defect at delayed imaging was not associated with residual glucose metabolic activity. Thus, PET can be used to detect glucose metabolic activity in a significant proportion of myocardial segments with fixed or partially redistributing defects seen at thallium SPECT, which suggests that the extent of tissue viability in patients with ischemic heart disease is underestimated at thallium scintigraphy.

  2. Assessment of myocardial viability using F-18 fluorodeoxyglucose/Tc-99m sestamibi dual-isotope simultaneous acquisition SPECT: comparison with Tl-201 stress-reinjection SPECT.

    Science.gov (United States)

    Wu, Yen-Wen; Huang, Por-Jau; Lee, Chii-Ming; Ho, Yi-Lwun; Lin, Lung-Chun; Wang, Tzung-Dau; Wang, Shoei-Shen; Chen, Tony Hsiu-Hsi; Yen, Ruoh-Fang

    2005-01-01

    This study compared technetium 99m sestamibi/fluorine 18 fluorodeoxyglucose dual-isotope simultaneous acquisition (DISA) with stress-reinjection thallium 201 single photon emission computed tomography (SPECT) with regard to their ability to detect myocardial viability. The study cohort consisted of 42 angiographically significant coronary artery disease patients with symptomatic congestive heart failure or regional wall motion abnormalities. In total, 398 dysfunctional segments in 40 patients were analyzed (2 patients were excluded because of poor-quality F-18 fluorodeoxyglucose images). Of the segments, 217 were diagnosed as viable and 144 as nonviable by both DISA and Tl-201, 33 were viable by DISA but nonviable by Tl-201, and 4 were viable by Tl-201 but nonviable by DISA. Most discrepancies were in the inferior wall. Of the 40 patients, 16 underwent revascularization. From the follow-up results for the 105 dysfunctional segments in these 16 patients, DISA viability appears to be a significant predicting factor (P = .014) for functional recovery after revascularization statistically whereas Tl-201 viability does not (P = .09). Our study suggests that DISA viability provides more accurate prediction of postrevascularization functional recovery than Tl-201 viability. Given the small number of patients who underwent revascularization, the superiority of DISA over Tl-201 in detecting myocardial viability may be firmly established by further study on a large scale for patients with profound left ventricular dysfunction.

  3. Microvascular obstruction on delayed enhancement cardiac magnetic resonance imaging after acute myocardial infarction, compared with myocardial {sup 201}Tl and {sup 123}I-BMIPP dual SPECT findings

    Energy Technology Data Exchange (ETDEWEB)

    Mori, Hiroaki [Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya (Japan); Department of Cardiology, Kainan Hospital, Yatomi (Japan); Isobe, Satoshi, E-mail: sisobe@med.nagoya-u.ac.jp [Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya (Japan); Sakai, Shinichi [Department of Cardiology, Kainan Hospital, Yatomi (Japan); Yamada, Takashi [Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya (Japan); Watanabe, Naoki; Miura, Manabu [Department of Cardiology, Kainan Hospital, Yatomi (Japan); Uchida, Yasuhiro; Kanashiro, Masaaki; Ichimiya, Satoshi [Department of Cardiology, Yokkaichi Municipal Hospital, Yokkaichi (Japan); Okumura, Takahiro; Murohara, Toyoaki [Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya (Japan)

    2015-08-15

    Highlights: • The percentage infarct size (%IS) was significantly greater in the microvascular obstruction (MO) group than in the non-MO group. • The percentage mismatch score (%MMS) on dual scintigraphy significantly correlated with the %IS and the percentage MO. • The %MMS was significantly greater in the non-MO group than in the MO group, and was an independent predictor for MO. - Abstract: Background: The hypo-enhanced regions within the hyper-enhanced infarct areas detected by cardiac magnetic resonance (CMR) imaging reflect microvascular obstruction (MO) after acute myocardial infarction (AMI). The combined myocardial thallium-201 ({sup 201}Tl)/iodine-123-15-(p-iodophenyl)-3-(R,S)-methylpentadecanoic acid ({sup 123}I-BMIPP) dual single-photon emission computed tomography (SPECT) is a useful tool for detecting myocardial reversibility after AMI. We evaluated whether MO could be an early predictor of irreversible myocardial damage in comparison with {sup 201}Tl and {sup 123}I-BMIPP dual SPECT findings in AMI patients. Methods: Sixty-two patients with initial AMI who successfully underwent coronary revascularization were enrolled. MO was defined by CMR imaging. Patients were divided into 2 groups as follows: MO group (n = 32) and non-MO group (n = 30). Scintigraphic defect scores were calculated using a 17-segment model with a 5-point scoring system. The mismatch score (MMS) was calculated as follows: the total sum of (Σ) {sup 123}I-BMIPP defect score minus Σ{sup 201}Tl defect score. The percentage mismatch score (%MMS) was calculated as follows: MMS/(Σ{sup 123}I-BMIPP score) × 100 (%). Results: The percentage infarct size (%IS) was significantly greater in the MO group than in the non-MO group (32.2 ± 13.8% vs. 18.3 ± 12.1%, p < 0.001). The %MMS significantly correlated with the %IS and the percentage MO (r = −0.26, p = 0.03; r = −0.45, p < 0.001, respectively). The %MMS was significantly greater in the non-MO group than in the MO group (45.4

  4. Evaluation of muscular lesions in connective tissue diseases: thallium 201 muscular scans

    Energy Technology Data Exchange (ETDEWEB)

    Guillet, G.; Guillet, J.; Sanciaume, C.; Maleville, J.; Geniaux, M.; Morin, P.

    1988-04-01

    We performed thallium 201 muscle scans to assess muscular involvement in 40 patients with different connective tissue diseases (7 with dermatomyositis, 7 with systemic lupus erythematosus, 12 with progressive systemic scleroderma, 2 with calcinosis, Raynaud's phenomenon, esophageal involvement, sclerodactyly, and telangiectasia (CREST) syndrome, 3 with monomelic scleroderma, 6 with morphea, and 3 with Raynaud's disease). Only 12 of these patients complained of fatigability and/or myalgia. Electromyography was performed and serum levels of muscle enzymes were measured in all patients. Comparison of thallium 201 exercise recording with the other tests revealed that scan sensitivity is greater than electromyographic and serum muscle enzymes levels. Thallium 201 scans showed abnormal findings in 32 patients and revealed subclinical lesions in 18 patients, while electromyography findings were abnormal in 25 of these 32 patients. Serum enzyme levels were raised in only 8 patients. Thallium 201 scanning proved to be a useful guide for modifying therapy when laboratory data were conflicting. It was useful to evaluate treatment efficacy. Because our data indicate a 100% positive predictive value, we believe that thallium 201 scanning should be advised for severe systemic connective tissue diseases with discordant test results.

  5. Early and delayed thallium-201 scintigraphy in thyroid nodules: the relationship between early thallium-201 uptake and perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Derebek, E. [Dept. of Nuclear Medicine, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Biberoglu, S. [Dept. of Internal Medicine, Div. of Endocrinology, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Kut, O. [Dept. of Nuclear Medicine, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Yesil, S. [Dept. of Internal Medicine, Div. of Endocrinology, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Saydam, S. [Dept. of Surgery, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Yilmaz, M. [Dept. of Nuclear Medicine, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Yenici, O. [Dept. of Nuclear Medicine, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Igci, E. [Dept. of Radiology, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Gokce, O. [Dept. of Surgery, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Canda, S. [Dept. of Pathology, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Bueyuekgebiz, A. [Dept. of Pediatrics, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Dogan, A.S. [Dept. of Nuclear Medicine, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Durak, H. [Dept. of Nuclear Medicine, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey)

    1996-05-01

    Seventy-six patients with tyroid nodules were studied. Initially, 75 MBq of thallium-201 was injected. The thyroid gland was imaged 15 min (early) and 3 h (delayed) after the injection. Thereafter, 185 MBq technetium-99m pertechnetate was injected. Immediately after the injection, a 1-min perfusion image was acquired, followed by an image at 20 min. Increased early and delayed {sup 201}Tl uptake compared with the contralateral thyroid tissue was adopted as the criterion for malignancy. Sensitivity, specificity and negative predictive values were found to be 85%, 64% and 78%, respectively, in operated patients, but these values were 86%, 87% and 95%, respectively, in the whole group, including patients followed with fine-needle aspiration biopsy. With the purpose of investigating the relationship between perfusion and early {sup 201}Tl uptake, bot perfusion and early images were graded comparing nodular activity with contralateral thyroid activity. There was a poor correlation between perfusion and {sup 201}Tl uptake. The correlation was even worse in hyperactive nodules. It is concluded that early and delayed {sup 201}Tl imaging should not be used in the differential diagnosis of cold nodules and that early {sup 201}Tl uptake seems to be more closely related to factors other than perfusion. (orig.)

  6. Area at risk can be assessed by iodine-123-meta-iodobenzylguanidine single-photon emission computed tomography after myocardial infarction: a prospective study.

    Science.gov (United States)

    Hedon, Christophe; Huet, Fabien; Ben Bouallegue, Fayçal; Vernhet, Hélène; Macia, Jean-Christophe; Cung, Thien-Tri; Leclercq, Florence; Cade, Stéphane; Cransac, Frédéric; Lattuca, Benoit; Vandenberghe, D'Arcy; Bourdon, Aurélie; Benkiran, Meriem; Vauchot, Fabien; Gervasoni, Richard; D'estanque, Emmanuel; Mariano-Goulart, Denis; Roubille, François

    2018-02-01

    Myocardial salvage is an important surrogate endpoint to estimate the impact of treatments in patients with ST-segment elevation myocardial infarction (STEMI). The aim of this study was to evaluate the correlation between cardiac sympathetic denervation area assessed by single-photon emission computed tomography (SPECT) using iodine-123-meta-iodobenzylguanidine (I-MIBG) and myocardial area at risk (AAR) assessed by cardiac magnetic resonance (CMR) (gold standard). A total of 35 postprimary reperfusion STEMI patients were enrolled prospectively to undergo SPECT using I-MIBG (evaluates cardiac sympathetic denervation) and thallium-201 (evaluates myocardial necrosis), and to undergo CMR imaging using T2-weighted spin-echo turbo inversion recovery for AAR and postgadolinium T1-weighted phase sensitive inversion recovery for scar assessment. I-MIBG imaging showed a wider denervated area (51.1±16.0% of left ventricular area) in comparison with the necrosis area on thallium-201 imaging (16.1±14.4% of left ventricular area, Parea (P=0.23) and was adequately correlated (R=0.56, P=0.0002). Myocardial salvage evaluated by SPECT imaging (mismatch denervated but viable myocardium) was significantly higher than by CMR (P=0.02). In patients with STEMI, I-MIBG SPECT, assessing cardiac sympathetic denervation may precisely evaluate the AAR, providing an alternative to CMR for AAR assessment.

  7. Genotoxic and mutagenic effects of the diagnostic use of thallium-201 in nuclear medicine

    Energy Technology Data Exchange (ETDEWEB)

    Kelsey, K.T. (Harvard School of Public Health, Boston, MA (United States)); Donohoe, K.J. (Beth Israel Hospital, Boston, MA (United States). Div. of Nuclear Medicine); Baxter, Barbara; Memisoglu, Asli; Little, J.B.; Caggana, Michele; Liber, H.L. (Harvard School of Public Health, Boston, MA (United States))

    1991-07-01

    In order to investigate possible mutagenetic effects of in vivo exposure to low levels of ionizing radiation used in nuclear medicine, the authors examined hypoxanthine guanine phosphoribosyl transferase (hprt) mutant fraction (MF) and chromosome aberration (CA) frequency in 24 nuclear medicine patients before and after injection of thallium-201. The mean MF of the thallium-201-exposed cohort was 5.2{+-}4.4 x 10{sup -6} before injection exposure. No significant difference in MF was observed 24 h later. In 11 patients who were studied on a 3rd occasion, 30 days after thallium-201 exposure, there was again no significant difference in post-exposure as compared with the pre-exposure MF. The frequency of CA in peripheral blood lymphocytes was not significantly different, comparing pre- and 24h to 1 month post-radionuclide exposure . Thus, thallium-201 exposure was not associated with significant elevations in MF or CA frequency in lymphocytes of exposed individuals. (author). 40 refs.; 3 tabs.

  8. Syndrome of diminished vasodilator reserve of the coronary microcirculation (microvascular angina or syndrome X): Diagnosis by combined atrial pacing and thallium 201 imaging--a case report

    Energy Technology Data Exchange (ETDEWEB)

    Magarian, G.J.; Palac, R.; Reinhart, S. (Veterans Administration Medical Center, Portland, OR (USA))

    1990-08-01

    Patients with angina-like chest pain without evidence of epicardial coronary artery disease or coronary arterial vasospasm are becoming increasingly recognized. These are often related to noncardiac causes including esophageal, musculoskeletal, and hyperventilatory or panic states. However, recently a subgroup of such patients are being recognized as having true myocardial ischemia and chest pain on the basis of diminished coronary microvascular vasodilatory reserve (microvascular ischemia or Syndrome X). The authors describe such a patient who was found to have replication of anginal pain associated with a reversible ischemic defect on thallium 201 imaging during atrial pacing, suggesting ischemia in this myocardial segment. Resolution of angina and ST segment electrocardiographic changes of ischemia occurred with cessation of pacing. We believe this is the first report of a patient with this form of myocardial ischemia diagnosed by this method and should be considered in patients with anginal chest pain after significant coronary artery disease and coronary vasospasm have been excluded.

  9. Detection of human collateral circulation by vasodilation-thallium-201 tomography

    Energy Technology Data Exchange (ETDEWEB)

    Nienaber, C.A.; Salge, D.; Spielmann, R.P.; Montz, R.; Bleifeld, W. (University Hospital Eppendorf, Hamburg (Germany, F.R.))

    1990-04-15

    Coronary arteriolar vasodilation may provoke redistribution of flow to collateral-dependent jeopardized myocardium. To assess the physiologic significance of collaterals, 80 consecutive post-infarction patients (age 58 +/- 8 years) underwent vasodilation-redistribution thallium-201 tomographic imaging after administration of 0.56 mg of intravenous dipyridamole/kg body weight. Circumferential profile analysis of thallium-201 uptake and redistribution in representative left ventricular tomograms provided quantitative assessment of transient and fixed defects and separation between periinfarctional and distant inducible hypoperfusion. Tomographic perfusion data were correlated to wall motion and collateral circulation between distinct anatomic perfusion territories. Patients were grouped according to presence (59%) or absence (41%) of angiographically visible collateral channels to jeopardized myocardium. In the presence of collaterals, distant reversible defects were larger than in absence of collaterals (p less than 0.05); the extent of combined periinfarctional and distant redistribution was also larger in collateralized patients (p less than 0.025), whereas the size of the persistent perfusion defect was similar in both groups. By prospective analysis the tomographic perfusion pattern of combined periinfarctional and distant redistribution revealed a sensitivity of 85% and a specificity of 78% for the detection of significant collateral circulation in this group of patients. Thus, using the exhausted flow reserve as a diagnostic tool, vasodilation-thallium-201 tomography has the potential to identify and quantitate collateralized myocardium in post-infarction patients and may guide diagnostic and therapeutic decision-making.

  10. Low-dose dobutamine myocardial perfusion scintigraphy in the identification of viable myocardium

    Energy Technology Data Exchange (ETDEWEB)

    Moraes, Renata Freire de [Instituto Hermes Pardini, Belo Horizonte, MG (Brazil). Dept. of Molecular Imaging and Diagnosis. Div. of Nuclear Medicine; Meneghetti, Jose Claudio [Instituto do Coracao (InCor-HC/FM/USP), Sao Paulo, SP (Brazil). Unit of Nuclear Medicine and Molecular Imaging; Barroso, Adelanir Antonio, E-mail: renatafreire@yahoo.com.b [Nuclear Medcenter, Belo Horizonte, MG (Brazil)

    2010-09-15

    Objective: to evaluate the increase in specificity of dual isotope myocardial perfusion gated SPECT ({sup 99m}Tcsestamibi/thallium-201), a highly sensitive method to detect viable myocardium, with addition of data on contractile reserve simultaneously acquired by low-dose dobutamine gated SPECT, similarly to echocardiography. Materials and methods: a total of 260 myocardial segments were assessed in 13 patients with myocardial infarction referred for investigation of myocardial viability before undergoing revascularization. Cellular integrity and contractile reserve were evaluated by dual isotope perfusion myocardial gated SPECT with thallium rest and redistribution images and post-stress {sup 99m}Tc-sestamibi gated-SPECT images under basal conditions and with low-dose dobutamine. The improvement in the contractile performance detected by post-revascularization {sup 99m}Tc-sestamibi gated SPECT was the parameter considered for determining myocardial viability. For the purpose of results analysis, the functional parameters of the myocardial segments were quantified at the different phases of the study and stratified according to their viability for a later post-revascularization functional comparison. Results: in the statistical analysis, systolic wall thickening demonstrated to be a relevant parameter in the evaluation of myocardial contractile reserve by this method, with a tendency of improvement in the specificity (84%), demonstrating higher values than those observed in the literature. Conclusion: this method tends to present an effective contribution in the assessment of myocardial viability. (author)

  11. Dilatation of the left ventricular cavity on dipyridamole thallium-201 imaging: A new marker of triple-vessel disease

    Energy Technology Data Exchange (ETDEWEB)

    Takeishi, Y.; Tono-oka, I.; Ikeda, K.; Komatani, A.; Tsuiki, K.; Yasui, S. (Yamagata Univ. School of Medicine (Japan))

    1991-02-01

    To investigate the significance and mechanism of dilatation of the left ventricular cavity on dipyridamole thallium-201 imaging, we performed both dipyridamole thallium-201 imaging and dipyridamole radionuclide angiography on 83 patients with known angiograms. The dipyridamole/delayed ratio of the left ventricular dimension from the thallium-201 image was defined as the left ventricular dilatation ratio (LVDR). An LVDR greater than the mean + two standard deviations in patients without coronary artery disease was defined as abnormal. Twenty-two of 83 patients showed an abnormal LVDR, and 18 of the 22 patients (82%) had triple-vessel disease. By defect and washout analysis, the sensitivity and specificity for correctly identifying the patients as having triple-vessel disease was 72% and 76%, respectively, whereas LVDR had a sensitivity of 72% and a specificity of 93%. When LVDR was used in combination with the defect and washout criteria, sensitivity increased to 84% without a loss of specificity. In those 22 patients with abnormal LVDRs, end-diastolic volume measured by radionuclide angiography did not change after dipyridamole infusion. Dilatation of the left ventricular cavity on dipyridamole thallium-201 imaging reflected relative subendocardial hypoperfusion induced by dipyridamole rather than actual chamber enlargement. The LVDR was moderately sensitive and highly specific for triple-vessel disease and provided complementary information to dipyridamole thallium-201 imaging.

  12. Myocardial imaging artifacts caused by mitral valve annulus calcification

    Energy Technology Data Exchange (ETDEWEB)

    Wagoner, L.E.; Movahed, A.; Reeves, W.C. (East Carolina Univ. School of Medicine, Greenville, NC (USA))

    1991-02-01

    Knowledge of imaging artifact of myocardial perfusion studies with thallium-201 is critical for improving the diagnostic accuracy of coronary artery disease. Three patients are described who underwent exercise or pharmacologic stress thallium-201 imaging studies and had a moderate, fixed myocardial perfusion defect (scar) involving the posterolateral and inferoposterior walls of the left ventricle. This was an imaging artifact caused by a heavily calcified mitral valve annulus.

  13. Myocardial Perfusion Spect Imaging in Dextrocardia: A Case Report

    Directory of Open Access Journals (Sweden)

    Semra Özdemir

    2013-08-01

    Full Text Available The myocardial perfusion scintigraphy acquisition and analysis present some technical differences in the rare dextrocardia cases. Here we report a case of a 38 year-old woman with dextrocardia who had been applied myocardial perfusion scintigraphy. Presented case showed that the thoracic and abdominal organs had a mirror image with situs inversus totalis type dextrocardia. The incidence of coronary heart disease and life span of people with situs inversus totalis are the same as the normal population. So we may apply myocardial perfusion scintigraphy to this patient group. The current case is presented in order to remind the special applications of myocardial perfusion SPECT imaging in patients with dextrocardia.

  14. Qualitative evaluation of coronary flow during anesthetic induction using thallium-201 perfusion scans

    Energy Technology Data Exchange (ETDEWEB)

    Kleinman, B.; Henkin, R.E.; Glisson, S.N.; el-Etr, A.A.; Bakhos, M.; Sullivan, H.J.; Montoya, A.; Pifarre, R.

    1986-02-01

    Qualitative distribution of coronary flow using thallium-201 perfusion scans immediately postintubation was studied in 22 patients scheduled for elective coronary artery bypass surgery. Ten patients received a thiopental (4 mg/kg) and halothane induction. Twelve patients received a fentanyl (100 micrograms/kg) induction. Baseline thallium-201 perfusion scans were performed 24 h prior to surgery. These scans were compared with the scans performed postintubation. A thallium-positive scan was accepted as evidence of relative hypoperfusion. Baseline hemodynamic and ECG data were obtained prior to induction of anesthesia. These data were compared with the data obtained postintubation. Ten patients developed postintubation thallium-perfusion scan defects (thallium-positive scan), even though there was no statistical difference between their baseline hemodynamics and hemodynamics at the time of intubation. There was no difference in the incidence of thallium-positive scans between those patients anesthetized by fentanyl and those patients anesthetized with thiopental-halothane. The authors conclude that relative hypoperfusion, and possibly ischemia, occurred in 45% of patients studied, despite stable hemodynamics, and that the incidence of these events was the same with two different anesthetic techniques.

  15. Myocardial Perfusion Spect Imaging in Dextrocardia: A Case Report

    Science.gov (United States)

    Özdemir, Semra; Gazi, Emine

    2013-01-01

    The myocardial perfusion scintigraphy acquisition and analysis present some technical differences in the rare dextrocardia cases. Here we report a case of a 38 year-old woman with dextrocardia who had been applied myocardial perfusion scintigraphy. Presented case showed that the thoracic and abdominal organs had a mirror image with situs inversus totalis type dextrocardia. The incidence of coronary heart disease and life span of people with situs inversus totalis are the same as the normal population. So we may apply myocardial perfusion scintigraphy to this patient group. The current case is presented in order to remind the special applications of myocardial perfusion SPECT imaging in patients with dextrocardia. Conflict of interest:None declared. PMID:24003402

  16. Constrictive pericarditis causing a positive TI-201 SPECT stress test for myocardial ischemia

    Energy Technology Data Exchange (ETDEWEB)

    Matthews, R.J.; Lightfoote, J.; Grusd, R.S. (Diagnostic Imaging of Southern California Medical Group, Sherman Oaks (USA))

    1990-08-01

    A case of constritive pericarditis was demonstrated by a positive thallium SPECT stress test for myocardial ischemia. After pericardiectomy, the repeat thallium stress test was normal. The disappearance of the criteria for a positive test suggests that constrictive pericarditis can cause myocardial ischemia, which can be demonstrated by thallium SPECT stress testing.

  17. Myocardial scintigraphy in the diagnosis of myocardial contusion

    Energy Technology Data Exchange (ETDEWEB)

    Terashima, Masayoshi; Shinoda, Mitsutaka; Iwama, Hiroshi; Hirama, Hisao; Hoshino, Toshiaki; Urabe, Shinpei [Central Aizu General Hospital, Fukushima (Japan); Meguro, Taiichiroh

    1996-04-01

    To assess the clinical value of a new fatty acid imaging tracer, {sup 123}I-{beta}-methyl iodophenyl pentadecanoic acid (BMIPP), I-BMIPP and thallium-201 (Tl) dual imaging was performed at rest in fifteen patients with mild blunt chest trauma (mean AIS thoracic 1.4{+-}0.51, mean ISS 6.47{+-}3.50, mean RTS 7.69{+-}0.43). All patients were prospectively evaluated on the basis of serial electrocardiograms (ECG) and cardiac enzyme studies (total CPK). Tl and BMIPP dual scintigrams were performed within 10 days following admission. SPECT images were divided into seven segments, and the segmental images were visually scored according to tracer uptake on a 3 (severely decreased tracer uptake) to 0 (normal) scale. Nine patients had scintigraphic defects and were considered to have a myocardial contusion. ECG findings, AIS, ISS, and CPK levels failed to distinguish between scintigraphically positive patients and scintigraphically negative patients. Five of the 14 hypoperfused segments on BMIPP imaging, showed normal Tl uptake, one showed lower BMIPP uptake than Tl, and the remaining eight showed similar distribution of both tracers. The mismatch between tracer uptake on BMIPP images and Tl images was thought to reflect impaired myocardial fatty acid metabolism. Thus, mild blunt chest trauma results in a higher frequency of traumatic myocardial injury than previously recognized, and BMIPP is a promising radio-pharmaceutical for evaluating impaired myocardial fatty acid metabolism in patients with myocardial contusion. (author).

  18. Follow-up Thallium-201 scintigraphy after mantle field radiotherapy for Hodgkin's disease

    Energy Technology Data Exchange (ETDEWEB)

    Pierga, J.Y.; Girinski, T.; Henry-Amar, M. (Institut Gustave Roussy, Villejuif (France)); Maunoury, C.; Valette, H.; Tchernia, G.; Desgrez, A. (Centre Hospitalier de Bicetre, Le Kremlin-Bicetre (France)); Socie, G. (Institut Gustave Roussy, Villejuif (France) Hopital St Louis, Paris (France)); Cosset, J.M. (Institut Gustave Roussy, Villejuif (France) Institut Curie, Paris (France))

    1993-04-02

    Assessment of the long-term cardiac effects of mediastinal radiotherapy for Hodgkin's disease, by Thallium scintigraphy. 32 patients (14 males and 18 females) who underwent mantle field radiotherapy for Hodgkin's disease were included in this study. Twenty patients received 4 fractions of 2.5 Gy per week and 12, five fraction of 2 Gy per week, delivered on alternate days. All the patients, except three, performed exercise testing electrocardiogram and Thallium-201 tomoscintigraphy. The average time interval from completion of treatment to the study was 7 years (range 3--13 years). No patients had clinical symptoms of cardiac disease. Mean age at the time of the study was 35 years (range 23--48 years). Two electrocardiograms revealed left bundle branch block and the patients were excluded from the study. Only one out of 27 exercise electrocardiograms was abnormal in a patient with mitral valve prolapse, who was also excluded from the study. Twenty-six scintigraphies were evaluable. Twenty-two (85%) were clearly abnormal with partial or complete redistribution on delayed images. The anterior region was affected in 19 of these cases (86%). Four explorations were undoubtedly normal. Coronary angiography was not performed for ethical reasons in these asymptomatic patients. Despite possible false positive tests, the high rate of abnormality (85%) in this small series is striking. These preliminary data justify larger studies and a close long-term follow-up of these patients. 24 refs., 1 fig., 2 tabs.

  19. Thallium-201 for cardiac stress tests: residual radioactivity worries patients and security.

    Science.gov (United States)

    Geraci, Matthew J; Brown, Norman; Murray, David

    2012-12-01

    A 47-year-old man presented to the Emergency Department (ED) in duress and stated he was "highly radioactive." There were no reports of nuclear disasters, spills, or mishaps in the local area. This report discusses the potential for thallium-201 (Tl-201) patients to activate passive radiation alarms days to weeks after nuclear stress tests, even while shielded inside industrial vehicles away from sensors. Characteristics of Tl-201, as used for medical imaging, are described. This patient was twice detained by Homeland Security Agents and searched after he activated radiation detectors at a seaport security checkpoint. Security agents deemed him not to be a threat, but they expressed concern regarding his health and level of personal radioactivity. The patient was subsequently barred from his job and sent to the hospital. Tl-201 is a widely used radioisotope for medical imaging. The radioactive half-life of Tl-201 is 73.1h, however, reported periods of extended personal radiation have been seen as far out as 61 days post-administration. This case describes an anxious, but otherwise asymptomatic patient presenting to the ED with detection of low-level personal radiation. Documentation should be provided to and carried by individuals receiving radionuclides for a minimum of five to six half-lives of the longest-lasting isotope provided. Patients receiving Tl-201 should understand the potential for security issues; reducing probable tense moments, confusion, and anxiety to themselves, their employers, security officials, and ED staff. Copyright © 2012 Elsevier Inc. All rights reserved.

  20. Clinical usefulness of myocardial scintigraphy for diagnosis of ischemic heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Tsuji, Sotoyuki; Murakami, Eiji; Takekoshi, Noboru (Kanazawa Medical Univ. (Japan))

    1983-03-01

    Methods for noninvasive diagnosis an evaluation of coronary artery disease have been dramatically advanced by the development of myocardial scintigraphy. In this paper, 225 patients with coronary artery disease were studied with the following results: (1) With the use of 99mTc-PYP acute myocardial infarction areas were successfully detected in 80 % of the patients. (2) In the detection of myocardial infarction coincidence of the location of scan site defined by electrocardiogram with that of thallium defect at rest was 72 %. Coincidence of the area of dyssynergy in left ventriculogram with the site of thallium defect was 79 %. (3) The sensitivity of thallium-201 myocardial scintigram was 54 % and the specificity was 82 % in detecting angina pectoris. In detecting myocardial infarction the sensitivity was 81 % and the specificity was 75 %. In LCX the sensitivity of thallium-201 decreased considerably. (4) The sensitivity and specificity of thallium-201 imaging in detection of coronary artery disease after exercise were 78 % and 63 %, respectively.

  1. Patient satisfaction with coronary CT angiography, myocardial CT perfusion, myocardial perfusion MRI, SPECT myocardial perfusion imaging and conventional coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Feger, S.; Rief, M.; Zimmermann, E.; Richter, F.; Roehle, R. [Freie Universitaet Berlin, Department of Radiology, Charite - Universitaetsmedizin Berlin Campus Mitte, Humboldt-Universitaet zu Berlin, Berlin (Germany); Dewey, M. [Freie Universitaet Berlin, Department of Radiology, Charite - Universitaetsmedizin Berlin Campus Mitte, Humboldt-Universitaet zu Berlin, Berlin (Germany); Institut fuer Radiologie, Berlin (Germany); Schoenenberger, E. [Medizinische Hochschule Hannover, Department of Medicine, Hannover (Germany)

    2015-07-15

    To evaluate patient acceptance of noninvasive imaging tests for detection of coronary artery disease (CAD), including single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI), stress perfusion magnetic resonance imaging (MRI), coronary CT angiography (CTA) in combination with CT myocardial stress perfusion (CTP), and conventional coronary angiography (CCA). Intraindividual comparison of perception of 48 patients from the CORE320 multicentre multinational study who underwent rest and stress SPECT-MPI with a technetium-based tracer, combined CTA and CTP (both with contrast agent, CTP with adenosine), MRI, and CCA. The analysis was performed by using a validated questionnaire. Patients had significantly more concern prior to CCA than before CTA/CTP (p < 0.001). CTA/CTP was also rated as more comfortable than SPECT-MPI (p = 0.001). Overall satisfaction with CT was superior to that of MRI (p = 0.007). More patients preferred CT (46 %; p < 0.001) as a future diagnostic test. Regarding combined CTA/CTP, CTP was characterised by higher pain levels and an increased frequency of angina pectoris during the examination (p < 0.001). Subgroup analysis showed a higher degree of pain during SPECT-MPI with adenosine stress compared to physical exercise (p = 0.016). All noninvasive cardiac imaging tests are well accepted by patients, with CT being the preferred examination. (orig.)

  2. Myocardial perfusion defect on thallium-201 imaging in patients with chronic obstructive pulmonary disease

    Energy Technology Data Exchange (ETDEWEB)

    Mehrotra, P.P.; Weaver, Y.J.; Higginbotham, E.A.

    1983-08-01

    Six patients with angina pectoris had reversible perfusion defects on stress and redistribution thallium imaging. Three patients had a positive electrocardiographic response to exercise. No significant coronary artery lesions were seen on coronary arteriography in any of the six patients. All had mild to moderate hypoxemia at rest and physiologic evidence of chronic obstructive pulmonary disease as defined by the decrease in the ratio of forced expiratory volume at 1 second to forced vital capacity (FEV1/FVC X 100) or decrease in the forced midexpiratory flow rate (FEF25-75), or both. None had clinical findings suggestive of any of the reported causes of positive thallium scans in patients with normal coronary arteriograms. Cellular dysfunction produced by hypoxemia affecting the uptake of thallium seems to be the most likely mechanism of this abnormality.

  3. Clinical significance of {sup 123}I-BMIPP myocardial SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Yamazaki, Junichi [Toho Univ., Tokyo (Japan). School of Medicine

    1998-07-01

    {sup 123}I-BMIPP is a radioiodinated branched chain fatty acid analog, showing high accumulation as well as prolonged retention in the myocardium. Therefore, it is used as a metabolic imaging agent suitable for myocardial SPECT. After {sup 123}I-BMIPP is taken in the myocardium, it remains there mainly as a storage type fatty acid of triglyceride, and it shows different behavior by the stage of cardiac disease. Usually, we evaluate metabolic findings by early imaging (20 minutes) after intravenous injection of {sup 123}I-BMIPP, however, sometimes washout or fill in are seen in the case of myocardial infarction or hypertrophic cardiomyopathy by delayed imaging (after 4 hours). The mismatch of {sup 201}TlCl and {sup 123}I-BMIPP are useful for the diagnosis of stunned myocardium or evaluation of prognosis. However, behavior of {sup 123}I-BMIPP in myocardium is known still not completely. Therefore clinical significance of this examination is thought to be clarified by the stock of cases of various heart diseases. (author)

  4. EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT: 2015 revision

    Energy Technology Data Exchange (ETDEWEB)

    Verberne, Hein J.; Eck-Smit, Berthe L.F. van; Wit, Tim C. de [University of Amsterdam, Department of Nuclear Medicine, F2-238, Academic Medical Center, Amsterdam (Netherlands); Acampa, Wanda [National Council of Research, Institute of Biostructures and Bioimaging, Naples (Italy); Anagnostopoulos, Constantinos [Academy of Athens, Center for Experimental Surgery, Clinical and Translational Research, Biomedical Research Foundation, Athens (Greece); Ballinger, Jim [Guy' s Hospital - Guy' s and St Thomas' Trust Foundation, Department of Nuclear Medicine, London (United Kingdom); Bengel, Frank [Hannover Medical School, Department of Nuclear Medicine, Hannover (Germany); Bondt, Pieter De [OLV Hospital, Department of Nuclear Medicine, Aalst (Belgium); Buechel, Ronny R.; Kaufmann, Philip A. [University Hospital Zurich, Cardiac Imaging, Zurich (Switzerland); Cuocolo, Alberto [University Federico II, Department of Advanced Biomedical Sciences, Naples (Italy); Flotats, Albert [Universitat Autonoma de Barcelona, Nuclear Medicine Department, Hospital de la Santa Creu i Sant Pau, Barcelona (Spain); Hacker, Marcus [Medical University of Vienna, Division of Nuclear Medicine, Department of Biomedical Imaging and Image-Guided Therapy, Vienna (Austria); Hindorf, Cecilia [Skaane University Hospital, Department of Radiation Physics, Lund (Sweden); Lindner, Oliver [University Hospital of the Ruhr-University Bochum, Heart and Diabetes Center North Rhine-Westphalia, Institute for Radiology, Nuclear Medicine and Molecular Imaging, Bad Oeynhausen (Germany); Ljungberg, Michael [Lund University, Department of Medical Radiation Physics, Lund (Sweden); Lonsdale, Markus [Bispebjerg Hospital, Department of Clinical Physiology and Nuclear Medicine, Copenhagen (Denmark); Manrique, Alain [Caen University Hospital, Department of Nuclear Medicine, Service Commun Investigations chez l' Homme, GIP Cyceron, Caen (France); Minarik, David [Skaane University Hospital, Radiation Physics, Malmoe (Sweden); Scholte, Arthur J.H.A. [Leiden University Medical Center, Department of Cardiology, Leiden (Netherlands); Slart, Riemer H.J.A. [University of Groningen, University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); Traegaardh, Elin [Skaane University Hospital and Lund University, Clinical Physiology and Nuclear Medicine, Malmoe (Sweden); Hesse, Birger [University Hospital of Copenhagen, Department of Clinical Physiology and Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark)

    2015-11-15

    Since the publication of the European Association of Nuclear Medicine (EANM) procedural guidelines for radionuclide myocardial perfusion imaging (MPI) in 2005, many small and some larger steps of progress have been made, improving MPI procedures. In this paper, the major changes from the updated 2015 procedural guidelines are highlighted, focusing on the important changes related to new instrumentation with improved image information and the possibility to reduce radiation exposure, which is further discussed in relation to the recent developments of new International Commission on Radiological Protection (ICRP) models. Introduction of the selective coronary vasodilator regadenoson and the use of coronary CT-contrast agents for hybrid imaging with SPECT/CT angiography are other important areas for nuclear cardiology that were not included in the previous guidelines. A large number of minor changes have been described in more detail in the fully revised version available at the EANM home page: http://eanm.org/ publications/guidelines/2015{sub 0}7{sub E}ANM{sub F}INAL myocardial{sub p}erfusion{sub g}uideline.pdf. (orig.)

  5. Quantification of the myocardial area at risk using coronary CT angiography and Voronoi algorithm-based myocardial segmentation

    Energy Technology Data Exchange (ETDEWEB)

    Kurata, Akira; Kono, Atsushi; Coenen, Adriaan; Saru-Chelu, Raluca G.; Krestin, Gabriel P. [Erasmus University Medical Center, Department of Radiology, Rotterdam (Netherlands); Sakamoto, Tsuyoshi [AZE inc, Development Division, Chiyoda, Tokyo (Japan); Kido, Teruhito; Mochizuki, Teruhito [Ehime University Graduate School of Medicine, Department of Radiology, Toon, Ehime (Japan); Higashino, Hiroshi [Yotsuba Circulation Clinic, Department of Radiology, Matsuyama, Ehime (Japan); Abe, Mitsunori [Yotsuba Circulation Clinic, Department of Cardiology, Matsuyama, Ehime (Japan); Feyter, Pim J. de; Nieman, Koen [Erasmus University Medical Center, Department of Radiology, Rotterdam (Netherlands); Erasmus University Medical Center, Department of Cardiology, Rotterdam (Netherlands)

    2015-01-15

    The purpose of this study was to estimate the myocardial area at risk (MAAR) using coronary computed tomography angiography (CTA) and Voronoi algorithm-based myocardial segmentation in comparison with single-photon emission computed tomography (SPECT). Thirty-four patients with coronary artery disease underwent 128-slice coronary CTA, stress/rest thallium-201 SPECT, and coronary angiography (CAG). CTA-based MAAR was defined as the sum of all CAG stenosis (>50 %) related territories (the ratio of the left ventricular volume). Using automated quantification software (17-segment model, 5-point scale), SPECT-based MAAR was defined as the number of segments with a score above zero as compared to the total 17 segments by summed stress score (SSS), difference (SDS) score map, and comprehensive SPECT interpretation with either SSS or SDS best correlating CAG findings (SSS/SDS). Results were compared using Pearson's correlation coefficient. Forty-nine stenoses were observed in 102 major coronary territories. Mean value of CTA-based MAAR was 28.3 ± 14.0 %. SSS-based, SDS-based, and SSS/SDS-based MAAR was 30.1 ± 6.1 %, 20.1 ± 15.8 %, and 26.8 ± 15.7 %, respectively. CTA-based MAAR was significantly related to SPECT-based MAAR (r = 0.531 for SSS; r = 0.494 for SDS; r = 0.814 for SSS/SDS; P < 0.05 in each). CTA-based Voronoi algorithm myocardial segmentation reliably quantifies SPECT-based MAAR. (orig.)

  6. Feasibility of one-eighth time gated myocardial perfusion SPECT functional imaging using IQ-SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Caobelli, Federico; Thackeray, James T.; Bengel, Frank M. [Medizinische Hochschule Hannover, Klinik fuer Nuklearmedizin, Hannover (Germany); Soffientini, Alberto; Pizzocaro, Claudio; Guerra, Ugo Paolo [Fondazione Poliambulanza, Department of Nuclear Medicine, Brescia (Italy)

    2015-11-15

    IQ-SPECT, an add-on to general purpose cameras based on multifocal collimation, can reduce myocardial perfusion imaging (MPI) acquisition times to one-fourth that of standard procedures (to 12 s/view). In a phantom study, a reduction of the acquisition time to one-eighth of the standard time (to 6 s/view) was demonstrated as feasible. It remains unclear whether such a reduction could be extended to clinical practice. Fifty patients with suspected or diagnosed CAD underwent a 2-day stress-rest {sup 99m}Tc-sestamibi MPI protocol. Two consecutive SPECT acquisitions (6 and 12 s/view) were performed. Electrocardiogram-gated images were reconstructed with and without attenuation correction (AC). Polar maps were generated and visually scored by two blinded observers for image quality and perfusion in 17 segments. Global and regional summed stress score (SSS), summed rest score (SRS) and summed difference score (SDS) were determined. Left ventricular volumes and ejection fraction were calculated based on automated contour detection. Image quality was scored higher with the 12 s/view acquisition, both with and without AC. Summed scores were statistically comparable between the 6 s/view and the 12 s/view acquisition, both globally and in individual coronary territories (e.g. in images with AC, SSS were 6.6 ± 8.3 and 6.2 ± 8.2 with 6 s and 12 s/view, respectively, p = 0.10; SRS were 3.9 ± 5.6 and 3.5 ± 5.3, respectively, p = 0.19; and SDS were 2.8 ± 5.7 and 2.6 ± 5.7, respectively, p = 0.59). Both acquisitions allowed MPI-based diagnosis of CAD in 25 of the 50 patients (with AC). Calculated end-diastolic volume (EDV) and end-systolic volume (ESV) were modestly higher with the 6 s/view acquisition than with the 12 s/view acquisition (EDV +4.8 ml at rest and +3.7 ml after stress, p = 0.003; ESV +4.1 ml at rest and +2.6 ml after stress, p = 0.01), whereas the ejection fraction did not differ (-1.2 % at rest, p = 0.20, and -0.9 % after stress, p = 0.27). Image quality and

  7. Simultaneous dipyridamole/maximal subjective exercise with 99mTc-MIBI SPECT: improved diagnostic yield in coronary artery disease.

    Science.gov (United States)

    Candell-Riera, J; Santana-Boado, C; Castell-Conesa, J; Aguadé-Bruix, S; Olona, M; Palet, J; Cortadellas, J; García-Burillo, A; Soler-Soler, J

    1997-03-01

    We attempted to demonstrate that simultaneous dipyridamole administration and maximal subjective exercise in patients who are unable to achieve a good exercise level can improve the diagnostic efficacy of technetium-99m methoxy isobutyl isonitrile (99mTc-MIBI) myocardial single-photon emission computed tomography (SPECT). The results of myocardial perfusion scintigraphy are unsatisfactory if the level of exercise achieved by the patient is insufficient. The use of dipyridamole with maximal subjective stress testing has been shown to improve the quality of the thallium-201 myocardial perfusion images, but there are no studies demonstrating that this combination improves the diagnostic accuracy of myocardial perfusion SPECT. Two hundred thirty-one consecutive patients, without a previous myocardial infarction, were classified into three groups: group 1, 91 patients with an adequate exercise test; group 2, 68 patients with an inadequate exercise test; group 3, 72 patients with an inadequate exercise test who then received intravenous dipyridamole (0.56 mg/kg body weight over 4 min) simultaneously with exercise. Results for sensitivity (89%) and negative predictive value (83%) in group 3 were significantly better than those in group 2 (71% [p = 0.03] and 56% [p = 0.002], respectively) and not significantly different from those in group 1. The polar maps of 20 patients studied with an without dipyridamole at the same exercise level revealed a significantly greater extent of ischemia in each territory and in a global assessment (19 + 20% vs. 8 + 11%, p < 0.0001) when dipyridamole was administered during physical exercise. Intravenous dipyridamole administration during exercise testing is advisable in all patients who are unable to achieve an adequate exercise level. This approach permits physicians to avoid missing ergometric information while optimizing myocardial SPECT results.

  8. Feasibility of one-eighth time gated myocardial perfusion SPECT functional imaging using IQ-SPECT.

    Science.gov (United States)

    Caobelli, Federico; Thackeray, James T; Soffientini, Alberto; Bengel, Frank M; Pizzocaro, Claudio; Guerra, Ugo Paolo

    2015-11-01

    IQ-SPECT, an add-on to general purpose cameras based on multifocal collimation, can reduce myocardial perfusion imaging (MPI) acquisition times to one-fourth that of standard procedures (to 12 s/view). In a phantom study, a reduction of the acquisition time to one-eighth of the standard time (to 6 s/view) was demonstrated as feasible. It remains unclear whether such a reduction could be extended to clinical practice. Fifty patients with suspected or diagnosed CAD underwent a 2-day stress-rest (99m)Tc-sestamibi MPI protocol. Two consecutive SPECT acquisitions (6 and 12 s/view) were performed. Electrocardiogram-gated images were reconstructed with and without attenuation correction (AC). Polar maps were generated and visually scored by two blinded observers for image quality and perfusion in 17 segments. Global and regional summed stress score (SSS), summed rest score (SRS) and summed difference score (SDS) were determined. Left ventricular volumes and ejection fraction were calculated based on automated contour detection. Image quality was scored higher with the 12 s/view acquisition, both with and without AC. Summed scores were statistically comparable between the 6 s/view and the 12 s/view acquisition, both globally and in individual coronary territories (e.g. in images with AC, SSS were 6.6 ± 8.3 and 6.2 ± 8.2 with 6 s and 12 s/view, respectively, p = 0.10; SRS were 3.9 ± 5.6 and 3.5 ± 5.3, respectively, p = 0.19; and SDS were 2.8 ± 5.7 and 2.6 ± 5.7, respectively, p = 0.59). Both acquisitions allowed MPI-based diagnosis of CAD in 25 of the 50 patients (with AC). Calculated end-diastolic volume (EDV) and end-systolic volume (ESV) were modestly higher with the 6 s/view acquisition than with the 12 s/view acquisition (EDV +4.8 ml at rest and +3.7 ml after stress, p = 0.003; ESV +4.1 ml at rest and +2.6 ml after stress, p = 0.01), whereas the ejection fraction did not differ (-1.2 % at rest, p = 0.20, and -0

  9. Detection of myocardial ischemia with myocardial perfusion SPECT in patients with diabetes mellitus

    Energy Technology Data Exchange (ETDEWEB)

    Seo, J. H.; Jeong, S. Y.; Bae, J. H.; Anh, B. C.; Lee, J.; Lee, K. B [Kyungpook National University Hospital, Daegu (Korea, Republic of)

    2004-07-01

    Diabetes mellitus(DM) is a critical disease associated with higher rates of cardiovascular morbidity and mortality. Atherosclerosis accounts for 65-80% of all deaths in diabetic patients and patients with DM are known to show high prevalence of coronary artery diseases(CAD). We evaluated the incidence of scintigraphic evidence of CAD in diabetic patients and results were compared with cardiovascular symptoms and clinical factors. 169 patients with DM(mean age 629years, 68 males) were referred for evaluation of CAD between Jan 2002 and Dec 2003. 101(60%) patients were with chest pain and 68(40%) were asymptomatic. Patients underwent exercise(n=6) or adenosine stress(n=163) SPECT myocardial perfusion imaging(MPI). Exclusion criteria included history of documented myocardial infarction, prior revascularization, clinically significant valvular heart disease, left-bundle branch block on rest ECG. We evaluated symptoms associated with cardiac problem and other clinical and laboratory data to reveal correlation with presence of CAD. MPI were assessed visually and semi-quantitatively with C-Equal program. Myocardial ischemia was detected in 52(31%) patients. Among them, 41 had 1-vessel and 9 had 2-vessel disease. In 52 patients with ischemia, 28(54%) were male and 24(46%) were female. 20/68(29%) asymptomatic and 32/101(32%) symptomatic patients had ischemia. Higher prevalence of neuropathy, hypertension, higher blood glucose level, HbA1c and CRP was noted in patients with myocardial ischemia. Serum levels of cholesterol and LDL was not significantly different between patients with ischemia and with normal MPI findings. Abnormal MPI findings were not related with gender and age. These results show a high prevalence of abnormal MPI results in diabetic patients regardless of symptoms. Screening stress MPI in diabetic patients should be indicated irrespective of symptoms, especially in patients with neuropathy, hypertension, higher level of blood glucose, or increased CRP.

  10. Assessment of hibernating myocardium following coronary artery bypass grafting using resting {sup 201}Tl myocardial SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Oshima, Motoo; Higashi, Shizuka; Yasukochi, Hiroshi [Teikyo Univ., Tokyo (Japan). Faculty of Medicine; Hayase, Shuhei

    1995-03-01

    In this study, the effect of coronary artery bypass grafting (CABG) in 35 patients (pts) (male 29, female 6) with fixed defects were evaluated before and one month after surgery using resting {sup 201}Tl SPECT. Nine pts (7 old myocardial infarction; OMI) had 2 vessel disease (VD) and 26 pts (19 OMI) had 3 VD. Pts ages ranged from 41 to 75 (mean 61.4{+-}8.4) years. All 35 pts were divided into 4 groups according to the results of {sup 201}Tl SPECT and left ventriculogram pre- and post-CABG. Thirteen pts who improved of both {sup 201}Tl SPECT and wall motion scores post-CABG were considered as hibernating myocardium (group I). Nine patients who improved of {sup 201}Tl SPECT score but no change of wall motion were group II. Seven pts who improved of wall motion but no change of {sup 201}Tl SPECT score were group III. Six pts who had no improvement of both {sup 201}Tl SPECT and wall motion scores were group IV and considered as myocardial infarction. (author).

  11. A study of partial volume effect on SPECT imaging using myocardial phantom. With HCM (ASH) model myocardial phantom

    Energy Technology Data Exchange (ETDEWEB)

    Onoguchi, Masahisa [Kanazawa Univ. (Japan). School of Medicine

    1997-05-01

    In order to evaluate simultaneously both myocardial perfusion and regional wall motion using ECG-gated myocardial SPECT imaging, correction for the partial volume effect (PVE) should be performed. For the quantitative analysis of myocardial SPECT imaging in patients with hypertrophic cardiomyopathy (HCM), we formed a new phantom simulating HCM with various septal wall thicknesses and estimated PVE using the recovery coefficient (RC). The value of RC in all phantoms increased with increasing thickness of the septal wall reaching a plateau at 25 mm for the cylindrical phantom and 25 mm for the Ep-phantom. Compared with the RC value, the PMMA-phantom had little influence on PVE. Therefore, our results suggested that the count in the septal wall could be underestimated if PVE was corrected by the value obtained for the cylindrical phantom. In conclusion, our new phantom simulating HCM was useful in assessing PVE in the hypertrophic septal wall. (author)

  12. GATED SPECT TO EVALUATE LEFT VENTRICULAR MYOCARDIAL PERFUSION, FUNCTION AND DYSSYNCHRONY FOR RESYNCHRONIZATION THERAPY

    Directory of Open Access Journals (Sweden)

    E.N. Ostroumov

    2009-01-01

    Full Text Available The study included 15 consecutive patients with heart failure and substantial LV dyssynchrony undergoing CRT. Clinical and phase analysis of gated myocardial perfusion SPECT assessed at baseline, after 2–3 days and after 3–4 months of CRT. The results demonstrated inversely relationship between the response to CRT and the nonviable myocardium. Evaluation of myocardial viability is necessary to considered in the selection process for CRT.

  13. Acute myocardial infarction: estimation of at-risk and salvaged myocardium at myocardial perfusion SPECT 1 month after infarction.

    Science.gov (United States)

    Romero-Farina, Guillermo; Aguadé-Bruix, Santiago; Candell-Riera, Jaume; Pizzi, M Nazarena; Pineda, Victor; Figueras, Jaume; Cuberas, Gemma; de León, Gustavo; Castell-Conesa, Joan; García-Dorado, David

    2013-11-01

    To estimate at-risk and salvaged myocardium by using gated single photon emission computed tomography (SPECT) myocardial perfusion imaging after acute myocardial infarction (AMI). The study was approved by the hospital's Ethical Committee on Clinical Trials (trial register number, PR(HG)36/2000), and all patients gave informed consent. Forty patients (mean age, 61.78 years; eight women) with a first AMI underwent two gated SPECT examinations--one before percutaneous coronary intervention (PCI) and one 4-5 weeks after PCI. Myocardium at risk was estimated by assessing the perfusion defect at the first gated SPECT examination, and salvaged myocardium was estimated by assessing the risk area minus necrosis at the second examination. Myocardium at risk was estimated by determining the discordance between the areas of left ventricular (LV) wall motion and perfusion at the second examination. Concordance between tests was analyzed by means of linear regression analysis, the Pearson correlation, the intraclass correlation coefficient, and Bland-Altman analysis. An improvement in perfusion, wall motion, wall thickening, and LV ejection fraction (P Myocardial perfusion gated SPECT performed 1 month after early PCI in a first AMI provides potentially useful information on at-risk and salvaged myocardium. http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.13122324/-/DC1. RSNA, 2013

  14. Myocardial Infarction Area Quantification using High-Resolution SPECT Images in Rats

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Luciano Fonseca Lemos de [Divisão de Cardiologia, Departamento de Clínica Médica, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Mejia, Jorge [Faculdade de Medicina de São José do Rio Preto, São José do Rio Preto, SP (Brazil); Carvalho, Eduardo Elias Vieira de; Lataro, Renata Maria; Frassetto, Sarita Nasbine [Divisão de Cardiologia, Departamento de Clínica Médica, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Fazan, Rubens Jr.; Salgado, Hélio Cesar [Departamento de Fisiologia, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Galvis-Alonso, Orfa Yineth [Faculdade de Medicina de São José do Rio Preto, São José do Rio Preto, SP (Brazil); Simões, Marcus Vinícius, E-mail: msimoes@fmrp.usp.br [Divisão de Cardiologia, Departamento de Clínica Médica, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil)

    2013-07-15

    Imaging techniques enable in vivo sequential assessment of the morphology and function of animal organs in experimental models. We developed a device for high-resolution single photon emission computed tomography (SPECT) imaging based on an adapted pinhole collimator. To determine the accuracy of this system for quantification of myocardial infarct area in rats. Thirteen male Wistar rats (250 g) underwent experimental myocardial infarction by occlusion of the left coronary artery. After 4 weeks, SPECT images were acquired 1.5 hours after intravenous injection of 555 MBq of 99mTc-Sestamibi. The tomographic reconstruction was performed by using specially developed software based on the Maximum Likelihood algorithm. The analysis of the data included the correlation between the area of perfusion defects detected by scintigraphy and extent of myocardial fibrosis assessed by histology. The images showed a high target organ/background ratio with adequate visualization of the left ventricular walls and cavity. All animals presenting infarction areas were correctly identified by the perfusion images. There was no difference of the infarct area as measured by SPECT (21.1 ± 21.2%) and by histology (21.7 ± 22.0%; p=0.45). There was a strong correlation between individual values of the area of infarction measured by these two methods. The developed system presented adequate spatial resolution and high accuracy for the detection and quantification of myocardial infarction areas, consisting in a low cost and versatile option for high-resolution SPECT imaging of small rodents.

  15. Subendocardial versus transmural ischaemia in myocardial perfusion SPECT--a Monte Carlo study

    DEFF Research Database (Denmark)

    Bartosik, Jolanta; El-Ali, Henrik Hussein; Nilsson, Ulf

    2006-01-01

    Myocardial perfusion imaging with single-photon emission computed tomography (SPECT) is useful for the evaluation of patients with known or suspected coronary artery disease. Parameters of interest are the reduction in the blood perfusion (severity) and the lesion volume (extent). The aim of this...

  16. Comparison between stress myocardial perfusion SPECT recorded with cadmium-zinc-telluride and Anger cameras in various study protocols

    Energy Technology Data Exchange (ETDEWEB)

    Verger, Antoine; Karcher, Gilles [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); INSERM U947, Nancy (France); Nancyclotep Experimental Imaging Platform, Nancy (France); Djaballah, Wassila [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); INSERM U947, Nancy (France); Fourquet, Nicolas [Clinique Pasteur, Toulouse (France); Rouzet, Francois; Le Guludec, Dominique [AP-HP, Hopital Bichat, Department of Nuclear Medicine, Paris (France); INSERM U 773 Inserm and Denis Diderot University, Paris (France); Koehl, Gregoire; Roch, Veronique [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); Nancyclotep Experimental Imaging Platform, Nancy (France); Imbert, Laetitia [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); Nancyclotep Experimental Imaging Platform, Nancy (France); Centre Alexis Vautrin, Department of Radiotherapy, Vandoeuvre (France); Poussier, Sylvain [INSERM U947, Nancy (France); Nancyclotep Experimental Imaging Platform, Nancy (France); Fay, Renaud [INSERM, Centre d' Investigation Clinique CIC-P 9501, Nancy (France); Marie, Pierre-Yves [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); Nancyclotep Experimental Imaging Platform, Nancy (France); INSERM U961, Nancy (France); Hopital de Brabois, CHU-Nancy, Medecine Nucleaire, Vandoeuvre-les-Nancy (France)

    2013-03-15

    The results of stress myocardial perfusion SPECT could be enhanced by new cadmium-zinc-telluride (CZT) cameras, although differences compared to the results with conventional Anger cameras remain poorly known for most study protocols. This study was aimed at comparing the results of CZT and Anger SPECT according to various study protocols while taking into account the influence of obesity. The study population, which was from three different institutions equipped with identical CZT cameras, comprised 276 patients referred for study using protocols involving {sup 201}Tl (n = 120) or {sup 99m}Tc-sestamibi injected at low dose at stress ({sup 99m}Tc-Low; stress/rest 1-day protocol; n = 110) or at high dose at stress ({sup 99m}Tc-High; rest/stress 1-day or 2-day protocol; n = 46). Each Anger SPECT scan was followed by a high-speed CZT SPECT scan (2 to 4 min). Agreement rates between CZT and Anger SPECT were good irrespective of the study protocol (for abnormal SPECT, {sup 201}Tl 92 %, {sup 99m}Tc-Low 86 %, {sup 99m}Tc-High 98 %), although quality scores were much higher for CZT SPECT with all study protocols. Overall correlations were high for the extent of myocardial infarction (r = 0.80) and a little lower for ischaemic areas (r = 0.72), the latter being larger on Anger SPECT (p < 0.001). This larger extent was mainly observed in 50 obese patients who were in the {sup 201}Tl or {sup 99m}Tc-Low group and in whom stress myocardial counts were particularly low with Anger SPECT (228 {+-} 101 kcounts) and dramatically enhanced with CZT SPECT (+279 {+-} 251 %). Concordance between the results of CZT and Anger SPECT is good regardless of study protocol and especially when excluding obese patients who have low-count Anger SPECT and for whom myocardial counts are dramatically enhanced on CZT SPECT. (orig.)

  17. Effects of adenosine and a selective A2A adenosine receptor agonist on hemodynamic and thallium-201 and technetium-99m-sestaMIBI biodistribution and kinetics.

    Science.gov (United States)

    Mekkaoui, Choukri; Jadbabaie, Farid; Dione, Donald P; Meoli, David F; Purushothaman, Kailasnath; Belardinelli, Luiz; Sinusas, Albert J

    2009-10-01

    The purpose of this study was to compare a selective A(2A) adenosine receptor agonist (regadenoson) with adenosine in clinically relevant canine models with regard to effects on hemodynamics and thallium-201 ((201)Tl) and technetium-99m ((99m)Tc)-sestaMIBI biodistribution and kinetics. The clinical application of vasodilator stress for perfusion imaging requires consideration of the effects of these vasodilating agents on systemic hemodynamics, coronary flow, and radiotracer uptake and clearance kinetics. Sequential imaging and arterial blood sampling was performed on control, anesthetized closed-chest canines (n = 7) to evaluate radiotracer biodistribution and kinetics after either a bolus administration of regadenoson (2.5 microg/kg) or 4.5-min infusion of adenosine (280 microg/kg). The effects of regadenoson on coronary flow and myocardial radiotracer uptake were then evaluated in an open-chest canine model of a critical stenosis (n = 7). Results from ex vivo single-photon emission computed tomography were compared with tissue well-counting. The use of regadenoson compared favorably with adenosine in regard to the duration and magnitude of the hemodynamic effects and the effect on (201)Tl and (99m)Tc-sestaMIBI biodistribution and kinetics. The arterial blood clearance half-time was significantly faster for (99m)Tc-sestaMIBI (regadenoson: 1.4 +/- 0.03 min; adenosine: 1.5 +/- 0.08 min) than for (201)Tl (regadenoson: 2.5 +/- 0.16 min, p adenosine: 2.7 +/- 0.04 min, p regadenoson stress was significantly greater than the relative perfusion defect with (99m)Tc-sestaMIBI (0.69 +/- 0.03%, p regadenoson produced a hyperemic response comparable to a standard infusion of adenosine. The biodistribution and clearance of both (201)Tl and (99m)Tc-sestaMIBI during regadenoson were similar to adenosine vasodilation. Ex vivo perfusion images under the most ideal conditions permitted detection of a critical stenosis, although (201)Tl offered significant advantages over (99m

  18. Relationship between coronary contrast-flow quantitative flow ratio and myocardial ischemia assessed by SPECT MPI

    Energy Technology Data Exchange (ETDEWEB)

    Smit, Jeff M.; Rosendael, Alexander R. van; Jukema, J.W.; Delgado, Victoria; Bax, Jeroen J.; Scholte, Arthur J. [Leiden University Medical Center, Department of Cardiology, Leiden (Netherlands); Koning, Gerhard [Medis Medical Imaging Systems B.V., Leiden (Netherlands); Dibbets-Schneider, Petra [Leiden University Medical Center, Department of Nuclear Medicine, Leiden (Netherlands); Mertens, Bart J. [Leiden University Medical Center, Department of Medical Statistics, Leiden (Netherlands); Reiber, Johan H.C. [Medis Medical Imaging Systems B.V., Leiden (Netherlands); Leiden University Medical Center, Department of Radiology, Leiden (Netherlands)

    2017-10-15

    A new method has been developed to calculate fractional flow reserve (FFR) from invasive coronary angiography, the so-called ''contrast-flow quantitative flow ratio (cQFR)''. Recently, cQFR was compared to invasive FFR in intermediate coronary lesions showing an overall diagnostic accuracy of 85%. The purpose of this study was to investigate the relationship between cQFR and myocardial ischemia assessed by single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI). Patients who underwent SPECT MPI and coronary angiography within 3 months were included. The cQFR computation was performed offline, using dedicated software. The cQFR computation was based on 3-dimensional quantitative coronary angiography (QCA) and computational fluid dynamics. The standard 17-segment model was used to determine the vascular territories. Myocardial ischemia was defined as a summed difference score ≥2 in a vascular territory. A cQFR of ≤0.80 was considered abnormal. Two hundred and twenty-four coronary arteries were analysed in 85 patients. Overall accuracy of cQFR to detect ischemia on SPECT MPI was 90%. In multivariable analysis, cQFR was independently associated with ischemia on SPECT MPI (OR per 0.01 decrease of cQFR: 1.10; 95% CI 1.04-1.18, p = 0.002), whereas clinical and QCA parameters were not. Furthermore, cQFR showed incremental value for the detection of ischemia compared to clinical and QCA parameters (global chi square 48.7 to 62.6; p <0.001). A good relationship between cQFR and SPECT MPI was found. cQFR was independently associated with ischemia on SPECT MPI and showed incremental value to detect ischemia compared to clinical and QCA parameters. (orig.)

  19. Determination of left ventricular mass through SPECT imaging

    Science.gov (United States)

    Zárate-Morales, A.; Rodríguez-Villafuerte, M.; Martínez-Rodríguez, F.; Arévila-Ceballos, N.

    1998-08-01

    An edge detection algorithm has been applied to estimate left ventricular (LV) mass from single photon emission computed tomography (SPECT) thallium-201 images. The algorithm was validated using SPECT images of a phantom. The algorithm was applied to 20 patient studies from the Hospital de Cardiologia, Centro Médico Nacional Siglo XXI. Left ventricular masses derived from the stress and redistribution studies were highly correlated (r=0.96). The average LV masses obtained were 162±37 g and 169±34 g in the redistribution and stress studies, respectively.

  20. Estimate of myocardial salvage in late presentation acute myocardial infarction by comparing functional and perfusion abnormalities in predischarge gated SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Sotgia, Barbara; Sciagra, Roberto; Pupi, Alberto [University of Florence, Nuclear Medicine Unit, Department of Clinical Physiopathology, Florence (Italy); Parodi, Guido; Antoniucci, David [Careggi Hospital, Division of Cardiology, Florence (Italy); Kastrati, Adnan; Schoemig, Albert [Technische Universitaet, Deutsches Herzzentrum, Munich (Germany)

    2008-05-15

    We hypothesized that, because of persistent stunning, the extent of post-treatment functional abnormalities detected using gated single-photon emission computed tomography (SPECT) could be representative of the initial risk area in acute myocardial infarction (AMI) treated by reperfusion therapy. In 48 AMI patients, we acquired two {sup 99m}Tc-sestamibi gated SPECT studies (at admission with tracer injection before treatment and at discharge 5 to 10 days later). We assessed the myocardial salvage defined by the admission minus predischarge summed rest score, and we compared it with the value obtained by subtracting the extent of perfusion defect from the extent of wall motion or wall thickening abnormalities in predischarge gated SPECT. Myocardial salvage was expressed as salvage index (salvaged myocardium divided by initial risk area). There was a good correlation between summed rest score salvage index and wall motion (Spearman's {rho} = 0.754, p < 0.0001) or wall thickening salvage index (Spearman's {rho} = 0.798, p < 0.0001). The wall thickening salvage index was able to classify correctly the patients that had a summed rest score salvage index {>=} 0.10 with 73% sensitivity, 88% specificity, and 83% accuracy. The wall motion salvage index was highly sensitive (91%) but poorly specific (13%, p < 0.002 vs wall thickening salvage index) and less accurate (69%, p < 0.05 vs wall thickening salvage index). {sup 99m}Tc-sestamibi gated SPECT allows assessing myocardial salvage using only post-treatment data. The salvage index derived using wall thickening as surrogate of admission perfusion defect correlates well with the salvage index measured by comparing pre- and post-treatment perfusion defects. (orig.)

  1. Detection and dosimetry of gamma ray emitted from thallium-201 and technetium-99m based on chemiluminescence technique

    Energy Technology Data Exchange (ETDEWEB)

    Shourian, Mostafa [Laboratory of Microanalysis, Institute of Biochemistry and Biophysics, University of Tehran, P.O. Box 13145-1384, Tehran (Iran, Islamic Republic of); Tavakoli, Hassan, E-mail: tavakoli@ibb.ut.ac.i [Faculty of Medicine, Department of Physiology and Biophysics, Faculty of Medicine, Baqiyatollah University of Medical Sciences, P.O. Box 19395-6558, Tehran (Iran, Islamic Republic of); Ghourchian, Hedayatollah, E-mail: hadi@ibb.ut.ac.i [Laboratory of Microanalysis, Institute of Biochemistry and Biophysics, University of Tehran, P.O. Box 13145-1384, Tehran (Iran, Islamic Republic of); Rafiee-Pour, Hossain-Ali [Laboratory of Microanalysis, Institute of Biochemistry and Biophysics, University of Tehran, P.O. Box 13145-1384, Tehran (Iran, Islamic Republic of)

    2010-09-15

    This report describes the detection and dosimetry of gamma ray emitted from Thallium-201 ({sup 201}Tl) and Technetium-99m ({sup 99m}Tc) based on chemiluminescence technique. H{sub 2}O{sub 2} produced by two gamma emitter radioisotopes of {sup 201}Tl and {sup 99m}Tc were quantitatively measured by chemiluminescence method. Upon producing H{sub 2}O{sub 2} in a luminol alkaline solution, in the presence of diperiodatocuprate, as catalyst a chemical reaction was accrued and consequently the emitted light was measured. The determined H{sub 2}O{sub 2} concentration was correlated with the gamma ray detection and dosimetry. The sensitivity of chemiluminescence technique for {sup 201}Tl and {sup 99m}Tc dosimetry was determined to be 0.20 and 0.08 MBq/l (Mega Becquerel per liter) respectively (R.S.D. = %5, N = 3). The plotted calibration curves showed detection limits of 3.24 and 1.76 MBq/l for {sup 201}Tl and {sup 99m}Tc, respectively.

  2. Artifacts in Quantitative analysis of myocardial perfusion SPECT, using Cedars-Sinai QPS Software.

    Science.gov (United States)

    Malek, Hadi; Yaghoobi, Nahid; Hedayati, Raheleh

    2017-04-01

    Quantitative analysis of myocardial perfusion Single photon emission computerized tomography (SPECT) images is increasingly applied in modern nuclear cardiology practice, assisting in the interpretation of myocardial perfusion images (MPI). There are different extensively validated state-of-the-art software packages, including QPS (cedars-Sinai), Corridor 4DM (University of Michigan) and Emory cardiac toolbox (Emory university), providing highly accurate and reproducible data. However, these software packages may suffer from potential artifacts related to patient or technical factors. By recognizing the source of such artifacts, the interpreting physician can avoid misinterpretation of MPI study. In this review, we discuss some of technical pitfalls that may occur in Quantitative Perfusion SPECT software (QPS, cedars-Sinai Medical center).

  3. Optimization and comparison of simultaneous and separate acquisition protocols for dual isotope myocardial perfusion SPECT

    OpenAIRE

    Ghaly, Michael; Links, Jonathan M.; Frey, Eric C.

    2015-01-01

    Dual-isotope simultaneous-acquisition (DISA) rest-stress myocardial perfusion SPECT (MPS) protocols offer a number of advantages over separate acquisition. However, crosstalk contamination due to scatter in the patient and interactions in the collimator degrade image quality. Compensation can reduce the effects of crosstalk, but does not entirely eliminate image degradations. Optimizing acquisition parameters could further reduce the impact of crosstalk. In this paper we investigate the optim...

  4. Visual evaluation of I-123-betamethyliodophenylpentadecanoic acid (BMIPP) myocardial SPECT findings in hypertrophic cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Bunko, Hisashi; Tonami, Norihisa; Hisada, Kinichi (Kanazawa Univ. (Japan). School of Medicine)

    1993-03-01

    I-123-betamethyliodophenylpentadecanoic acid (BMIPP) is a branched fatty acid analogue for the imaging of myocardial metabolism. Seventeen patients with hypertrophic cardiomyopathy (HCM) and 17 patients with ischemic or valvular heart diseases (non-HCMs) were studied to evaluate the characteristic findings of the BMIPP myocardial images in HCM. Early (20 min) and delayed (3 hr) images were obtained after intravenous injection of 111 MBq of BMIPP with 3-headed SPECT. Tl-201 myocardial SPECT was also obtained within a week of BMIPP SPECT. Regional myocardial uptake of BMIPP relative to Tl-201 and its serial change from early to delayed images were visually evaluated in patient basis as well as segmental basis. Decreased uptake of BMIPP in HCM was frequently seen in anterior, septal, apical and inferior wall. Relatively decreased myocardial uptake of BMIPP (type H+B) was seen in 14 patients (82%) of HCM which was significantly higher than non-HCMs (12%, p<0.001). Number of segments with type H+B was higher in HCM than non-HCMs (mean: 4.59 vs 0.53, p<0.001). This relative decrease of BMIPP uptake was frequently seen in hypertrophied segments of HCM (71%, p<0.01). Serial decrease of regional BMIPP uptake was also frequently seen in HCM especially in hypertrophied myocardium than non-HCMs (76% vs 41%, p<0.01). This was concordant with segmental analysis (mean: 3.41 vs 1.06, p<0.01). Significant decrease in BMIPP image quality in HCM was concordant with higher frequency of serial decrease of BMIPP in HCM. In conclusion, HCM patients frequently showed abnormality of BMIPP uptake and retention which indicated the presence of metabolic abnormality in hypertrophied myocardium. (author).

  5. Reference Range of Functional Data of Gated Myocardial Perfusion SPECT by Quantitative Gated SPECT of Cedars-Sinai and 4D-MSPECT of Michigan University

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Do Young; Kim, Moo Hyun; Kim, Young Dae [College of Medicine, Univ. of Donga, Pusan (Korea, Republic of)

    2003-07-01

    Various programs have been developed for gating of myocardial perfusion SPECT. Among the those program, the most popular program is the Quantitative Gated SPECT (QGS)? developed by Cedars-Sinai hospital and most recently released program is 4D-MSPECT? developed by university of Michigan. It is important to know the reference range of the functional data of gated myocardial perfusion SPECT because it is necessary to determine abnormality of individual patient and echocardiographic data is different from those of gated SPECT. Tc-99m MIBI gated myocardial perfusion SPECT image was reconstructed by dual head gamma camera (Siemens, BCAM, esoft) as routine procedure and analyzed using QGS? and 4D-MSPECT? program. All patients (M: F=9: 18, Age 69{+-}9 yrs) showed normal myocardial perfusion. The patients with following characteristics were excluded: previous angina or MI history, ECG change with Q wave or ST-T change, diabetes melitius, hypercholesterolemia, typical chest pain, hypertension and cardiomyopathy. Pre-test likelihood of all patients was low. (1) In stress gated SPECT by QGS?, EDV was 73{+-}25 ml, ESV 25{+-}14 ml, EF 67{+-}11 % and area of first frame of gating 106.4{+-}21cm{sup 2}. In rest gated SPECT, EDV was 76{+-}26 ml, ESV 27{+-}15 ml, EF 66{+-}12 and area of first frame of gating 108{+-}20cm{sup 2}. (2) In stress gated SPECT by 4D-MSPECT?, EDV was 76{+-}28 ml, ESV 23{+-}16 ml, EF 72{+-}11 %, mass 115{+-}24 g and ungated volume 42{+-}15 ml. In rest gated SPECT, EDV was 75{+-}27 ml, ESV 23{+-}12 ml, EF 71{+-}9%, mass 113{+-}25g and ungate dvolume 42{+-}15 ml, (3) s-EDV, s-EF, r-ESV and r-EF were significantly different between QGS? and 4D-MSPECT? (each p=0.016, p<0.001. p=0.003 and p=0.001). We determined the normal reference range of functional parameters by QGS? and 4D-MSPECT? program to diagnose individually the abnormality of patients. And the reference ranges have to adopted to be patients by each specific gating program.

  6. Attenuation correction in myocardial perfusion SPECT/CT: effects of misregistration and value of reregistration.

    Science.gov (United States)

    Goetze, Sibyll; Brown, Tracy L; Lavely, William C; Zhang, Zhe; Bengel, Frank M

    2007-07-01

    The accuracy of myocardial perfusion SPECT improves with attenuation correction. Algorithms for attenuation correction in hybrid SPECT/CT systems have the potential for misregistration of emission and transmission scans because CT and SPECT are obtained sequentially. Misregistration will influence regional tracer distribution and may reduce diagnostic accuracy. This study focused on the role of misregistration in cardiac SPECT/CT and the performance of a software-based approach for reregistration. We included 105 consecutive patients who underwent clinical myocardial perfusion imaging on a SPECT/CT system. Images were quantitatively assessed for misregistration using fusion software. Results were recorded in millimeters in the x-, y-, and z-axes. Regional tracer uptake in 6 segments (anterior, septal, inferior, lateral, anteroapical, and inferoapical) for noncorrected and attenuation-corrected images before and after reregistration was obtained from polar maps. To determine the relative influence of misregistration, we correlated individual differences between noncorrected and attenuation-corrected images, as well as between attenuation-corrected images before and after reregistration, with the degree of misregistration in a multivariate analysis including additional clinical variables such as sex and body weight. The difference in regional radiotracer uptake was significant between noncorrected and attenuation-corrected images in all 6 segments and was most pronounced in the inferior wall. On multivariate analysis, misregistration contributed significantly to changes in radiotracer distribution in the anterior (P = 0.038), septal (P = 0.011), and inferior (P = 0.006) segments. The mean misregistration was 8.6 +/- 3.8 mm (1.25 +/- 0.55 pixel). Misregistration of one or more pixels was observed in 64% of studies. Reregistration of misalignment significantly affected regional radiotracer distribution in the segments shown to be influenced by misregistration

  7. Normal value of functional parameters in gated myocardial perfusion SPECT in patients with low risk of coronary artery disease: emory cardiac tool box program

    Energy Technology Data Exchange (ETDEWEB)

    Kang, D. Y.; Kim, M. H.; Kim, Y. D.; Kim, D. K. [Donga University College of Medicine, Busan (Korea, Republic of)

    2002-07-01

    Absolute value of the functional data of gated myocardial perfusion SPECT is necessary to determine that individual patient is normal or not. Tc-99m MIBI gated myocardial perfusion SPECT was performed using emory cardiac tool box program. All patients (M:F=15:36, age 64{+-}10 yrs) showed normal myocardial perfusion. The patients with following characteristics were excluded; previous angina or MI, ECG change with Q wave or ST-T change, diabetes mellitus, hypercholesterolemia, typical chest pain and hypertension. In all patients, myocardial mass is 117{+-}23 g in stress gated SPECT, 106{+-}22 g in stress ungated SPECT and 102{+-}21 g in rest ungated SPECT. EDV is 90{+-}28 ml, ESV 26{+-}20 ml, SV 66{+-}21 ml, EF 73{+-}10 % and TID 1.06{+-}0.14. Myocardial mass in rest ungated SPECT is significantly different between men and women (p=0.025). Myocardial mass is significantly different between stress gated SPECT and stress ungated SPECT (p=0.000), and between stress ungated SPECT and rest ungated SPECT (p=0.003). We provide normal value of functional parameters to determine the abnormality of individual patients in patients with low risk of coronary artery disease.

  8. EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT

    DEFF Research Database (Denmark)

    Verberne, Hein J; Acampa, Wanda; Anagnostopoulos, Constantinos

    2015-01-01

    Since the publication of the European Association of Nuclear Medicine (EANM) procedural guidelines for radionuclide myocardial perfusion imaging (MPI) in 2005, many small and some larger steps of progress have been made, improving MPI procedures. In this paper, the major changes from the updated ...

  9. EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT: 2015 revision

    NARCIS (Netherlands)

    Verberne, Hein J.; Acampa, Wanda; Anagnostopoulos, Constantinos; Ballinger, Jim; Bengel, Frank; de Bondt, Pieter; Buechel, Ronny R.; Cuocolo, Alberto; van Eck-Smit, Berthe L. F.; Flotats, Albert; Hacker, Marcus; Hindorf, Cecilia; Kaufmann, Philip A.; Lindner, Oliver; Ljungberg, Michael; Lonsdale, Markus; Manrique, Alain; Minarik, David; Scholte, Arthur J. H. A.; Slart, Riemer H. J. A.; Trägårdh, Elin; de Wit, Tim C.; Hesse, Birger

    2015-01-01

    Since the publication of the European Association of Nuclear Medicine (EANM) procedural guidelines for radionuclide myocardial perfusion imaging (MPI) in 2005, many small and some larger steps of progress have been made, improving MPI procedures. In this paper, the major changes from the updated

  10. EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT : 2015 revision

    NARCIS (Netherlands)

    Verberne, Hein J.; Acampa, Wanda; Anagnostopoulos, Constantinos; Ballinger, Jim; Bengel, Frank; De Bondt, Pieter; Buechel, Ronny R.; Cuocolo, Alberto; van Eck-Smit, Berthe L. F.; Flotats, Albert; Hacker, Marcus; Hindorf, Cecilia; Kaufmann, Philip A.; Lindner, Oliver; Ljungberg, Michael; Lonsdale, Markus; Manrique, Alain; Minarik, David; Scholte, Arthur J. H. A.; Slart, Riemer H. J. A.; Tragardh, Elin; de Wit, Tim C.; Hesse, Birger

    2015-01-01

    Since the publication of the European Association of Nuclear Medicine (EANM) procedural guidelines for radionuclide myocardial perfusion imaging (MPI) in 2005, many small and some larger steps of progress have been made, improving MPI procedures. In this paper, the major changes from the updated

  11. Value of attenuation correction in stress-only myocardial perfusion imaging using CZT-SPECT.

    Science.gov (United States)

    van Dijk, J D; Mouden, M; Ottervanger, J P; van Dalen, J A; Knollema, S; Slump, C H; Jager, P L

    2017-04-01

    Attenuation correction (AC) improves the diagnostic outcome of stress-only myocardial perfusion imaging (MPI) using conventional SPECT. Our aim was to determine the value of AC using a cadmium zinc telluride-based (CZT)-SPECT camera. We retrospectively included 107 consecutive patients who underwent stress-optional rest MPI CZT-SPECT/CT. Next, we created three types of images for each patient; (1) only displaying reconstructed data without the CT-based AC (NC), (2) only displaying AC, and (3) with both NC and AC (NC + AC). Next, two experienced physicians visually interpreted these 321 randomized images as normal, equivocal, or abnormal. Image outcome was compared with all hard events over a mean follow-up time of 47.7 ± 9.8 months. The percentage of images interpreted as normal increased from 45% using the NC images to 72% using AC and to 67% using NC + AC images (P < .001). Hard event hazard ratios for images interpreted as normal were not different between using NC and AC (1.01, P = .99), or NC and NC + AC images (0.97, P = .97). AC lowers the need for additional rest imaging in stress-first MPI using CZT-SPECT, while long-term patient outcome remained identical. Use of AC reduces the need for additional rest imaging, decreasing the mean effective dose by up to 1.2 mSv.

  12. Comparison between stress myocardial perfusion SPECT recorded with cadmium-zinc-telluride and Anger cameras in various study protocols.

    Science.gov (United States)

    Verger, Antoine; Djaballah, Wassila; Fourquet, Nicolas; Rouzet, François; Koehl, Grégoire; Imbert, Laetitia; Poussier, Sylvain; Fay, Renaud; Roch, Véronique; Le Guludec, Dominique; Karcher, Gilles; Marie, Pierre-Yves

    2013-02-01

    The results of stress myocardial perfusion SPECT could be enhanced by new cadmium-zinc-telluride (CZT) cameras, although differences compared to the results with conventional Anger cameras remain poorly known for most study protocols. This study was aimed at comparing the results of CZT and Anger SPECT according to various study protocols while taking into account the influence of obesity. The study population, which was from three different institutions equipped with identical CZT cameras, comprised 276 patients referred for study using protocols involving (201)Tl (n = 120) or (99m)Tc-sestamibi injected at low dose at stress ((99m)Tc-Low; stress/rest 1-day protocol; n = 110) or at high dose at stress ((99m)Tc-High; rest/stress 1-day or 2-day protocol; n = 46). Each Anger SPECT scan was followed by a high-speed CZT SPECT scan (2 to 4 min). Agreement rates between CZT and Anger SPECT were good irrespective of the study protocol (for abnormal SPECT, (201)Tl 92 %, (99m)Tc-Low 86 %, (99m)Tc-High 98 %), although quality scores were much higher for CZT SPECT with all study protocols. Overall correlations were high for the extent of myocardial infarction (r = 0.80) and a little lower for ischaemic areas (r = 0.72), the latter being larger on Anger SPECT (p < 0.001). This larger extent was mainly observed in 50 obese patients who were in the (201)Tl or (99m)Tc-Low group and in whom stress myocardial counts were particularly low with Anger SPECT (228 ± 101 kcounts) and dramatically enhanced with CZT SPECT (+279 ± 251 %). Concordance between the results of CZT and Anger SPECT is good regardless of study protocol and especially when excluding obese patients who have low-count Anger SPECT and for whom myocardial counts are dramatically enhanced on CZT SPECT.

  13. The ECG component of Thallium-201 exercise testing impacts on cardiac intervention rates

    Energy Technology Data Exchange (ETDEWEB)

    Deague, J.; Salehi, N.; Grigg, L.; Lichtenstein, M.; Better, N. [Royal Melbourne Hospital, Parkville, VIC (Australia). Departments of Nuclear Medicine and Cardiology

    1998-06-01

    Full text: Thallium exercise testing (Tlex) offers superior sensitivity and specificity to exercise electrocardiography (ECG), but the value of the ECG data in Tlex remains poorly studied. While a normal Tlex is associated with an excellent prognosis, patients with a positive Tlex have a higher cardiac event rate. We aimed to see if a negative ECG Component of the Tlex (ECGTl) was associated with an improved outcome compared with a positive ECGTl, in those patients with a reversible Tlex defect. We followed 100 consecutive patients retrospectively with a reversible defect on Tlex (50 with negative and 50 with positive ECGTI) for 12 months. The ECG was reviewed as positive (1mm ST depression 0.08 seconds after J point or >2mm if on digoxin or prior ECG changes), negative, equivocal or uninterpretable. We excluded patients with pharmacological testing, and those with equivocal or uninterpretable ECGs. End-points included angiography, cardiac interventions and cardiac event rate (CER) incorporating unstable angina, acute myocardial infarction, and cardiac death. In conclusion 24% of patients with reversible defects on Tlex who had a negative ECGTI still proceeded to PTCA or CABG. Those with a positive ECGTI had a higher incidence of angiography and cardiac revascularisation, but this difference was only evident in patients with mild to moderate reversibility

  14. Clinical usefulness of {sup 123}I-BMIPP myocardial SPECT in collagen disease

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Kazuki; Zen, Kan [Asahi Univ., Gifu (Japan). Murakami Memorial Hospital; Sugihara, Hiroki (and others)

    2000-07-01

    This study was designed to evaluate the clinical usefulness of {sup 123}I-BMIPP myocardial SPECT for detecting cardiac involvement in patients with collagen disease. We studied 12 patients with systemic lupus erythematosus (SLE), 8 with progressive systemic sclerosis (PSS), 6 with polymyositis/dermatomyositis (PM/DM) and 3 with allergic granulomatosis and angiitis (AGA). A 111 MBq of {sup 123}I-BMIPP was intravenously injected at rest, and SPECT images were obtained at 15 min after the injection. Seven of 12 SLE, 6 of 8 PSS, 3 of 6 PM/DM and all 3 AGA patients showed an abnormal tracer uptake. The left ventricular ejection fraction was inversely correlated with a BMIPP abnormality. The regional wall motion abnormality was reduced in regions with reduced tracer uptake. These findings suggest that {sup 123}I-BMIPP imaging could be useful for assessment of cardiac involvement in patients with collagen disease. (author)

  15. Prognostic value of normal stress-only myocardial perfusion imaging: a comparison between conventional and CZT-based SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Yokota, Shu; Ottervanger, Jan Paul; Timmer, Jorik R. [Isala Hospital, Department of Cardiology, Zwolle (Netherlands); Mouden, Mohamed; Engbers, Elsemiek [Isala Hospital, Department of Cardiology, Zwolle (Netherlands); Isala Hospital, Department of Nuclear Medicine, Zwolle (Netherlands); Knollema, Siert; Jager, Pieter L. [Isala Hospital, Department of Nuclear Medicine, Zwolle (Netherlands)

    2016-02-15

    Single photon emission computed tomography (SPECT) myocardial perfusion imaging has proven to have prognostic importance in patients with suspected stable coronary artery disease (CAD). The recently introduced ultrafast cadmium zinc telluride (CZT)-based gamma cameras have been associated with less equivocal findings and more normal interpretations, allowing stress-only imaging to be performed more often. However, it is yet unclear whether normal stress-only CZT SPECT has comparable prognostic value as normally interpreted stress-only conventional SPECT. The study population consisted of 1,650 consecutive patients without known CAD with normal stress-only myocardial perfusion results with either conventional (n = 362) or CZT SPECT (n = 1,288). The incidence of major adverse cardiac events (MACE, all-cause death, non-fatal myocardial infarction and/or coronary revascularization) was compared between the conventional SPECT and CZT SPECT groups. Multivariable analyses using the Cox model were used to adjust for differences in baseline variables. Patients scanned with CZT were less often male (33 vs 39 %), had less often hypercholesterolaemia (41 vs 50 %) and had more often a family history of CAD (57 vs 49 %). At a median follow-up time of 37 months (interquartile range 28-45 months) MACE occurred in 68 patients. The incidence of MACE was 1.5 %/year in the CZT group, compared to 2.0 %/year in the conventional group (p = 0.08). After multivariate analyses, there was a trend to a lower incidence of MACE in the CZT SPECT group (hazard ratio 0.61, 95 % confidence interval 0.35-1.04, p = 0.07). The prognostic value of normal stress-only CZT SPECT is at least comparable and may be even better than that of normal conventional stress SPECT. (orig.)

  16. Real-time respiratory triggered SPECT myocardial perfusion imaging using CZT technology: impact of respiratory phase matching between SPECT and low-dose CT for attenuation correction.

    Science.gov (United States)

    Clerc, Olivier F; Fuchs, Tobias A; Possner, Mathias; Vontobel, Jan; Mikulicic, Fran; Stehli, Julia; Liga, Riccardo; Benz, Dominik C; Gräni, Christoph; Pazhenkottil, Aju P; Gaemperli, Oliver; Buechel, Ronny R; Kaufmann, Philipp A

    2017-01-01

    To assess the impact of respiratory phase matching between single-photon-emission computed tomography myocardial perfusion imaging (SPECT-MPI) and low-dose computed tomography (CT) for attenuation correction (AC). Forty patients underwent 1-day 99mTc-tetrofosmin pharmacological stress/rest SPECT-MPI using a cadmium-zinc-telluride gamma camera. Low-dose CT for AC was performed at deep-inspiration breath-hold. SPECT-MPI was acquired once with free-breathing (FB) and repeated at deep-inspiration breath-hold (BH) to match the respiratory phase of AC. From these acquisitions we reconstructed four data sets: free-breathing SPECT-MPI without AC (non-corrected; FB-NC), breath-hold SPECT-MPI without AC (non-corrected; BH-NC), free-breathing SPECT-MPI with AC (FB-AC), and breath-hold SPECT-MPI with AC (BH-AC), the latter representing respiratory-phase-matched AC SPECT-MPI. We compared semi-quantitative segmental tracer uptake, visual diagnosis, inter-observer agreement, and image quality. Compared with FB-NC, deep-inspiration BH-NC increases inferior and lateral uptake, but decreases septal uptake. Addition of AC to FB increases inferior and septal uptake, but decreases anterolateral uptake. Combining breath-hold MPI with breath-hold CT AC (BH-AC) increases inferior, inferolateral, and septal uptake, but reduces apical uptake, without affecting anterolateral uptake, with significant differences to all other protocols. Frequency of normal scans increases across protocols: 10% with FB-NC, 21% with BH-NC, 38% with FB-AC, and 51% with BH-AC. Image quality and inter-observer agreement were highest for BH-AC among all protocols. Compared with non-corrected breath-hold SPECT-MPI and with free-breathing AC SPECT-MPI, respiratory-phase-matched AC SPECT-MPI significantly affects segmental semi-quantitative uptake, increases the frequency of normal scans, yields the best inter-observer agreement, and significantly improves image quality. These findings suggest a potential role of

  17. Myocardial viability assessment with dynamic low-dose iodine-123-iodophenylpentadecanoic acid metabolic imaging: comparison with myocardial biopsy and reinjection SPECT thallium after myocardial infarction.

    Science.gov (United States)

    Murray, G L; Schad, N C; Magill, H L; Vander Zwaag, R

    1994-04-01

    Aggressive cardiac revascularization requires recognition of stunned and hibernating myocardium, and cost considerations may well govern the technique used. Dynamic low-dose (1 mCi) [123I]iodophenylpentadecanoic acid (IPPA) metabolic imaging is a potential alternative to PET using either 18FDG or 15O-water. Resting IPPA images were obtained from patients with severe ischemic cardiomyopathy, and transmural myocardial biopsies were obtained during coronary bypass surgery to confirm viability. Thirty-nine of 43 (91%) biopsies confirmed the results of the IPPA images with a sensitivity for viability of 33/36 (92%) and a specificity of 6/7 (86%). Postoperatively, wall motion improved in 80% of IPPA-viable, dysfunctional segments. Furthermore, when compared to reinjection thallium (SPECT-TI) scans after myocardial infarction, IPPA-SPECT-TI concordance occurred in 27/35 (77%) (K = 0.536, p = 0.0003). Similar to PET, IPPA demonstrated more viability than SPECT-TI, 26/35 (74%) versus 18/35 (51%) (p = 0.047). Metabolic IPPA cardiac viability imaging is a safe, inexpensive technique that may be a useful alternative to PET.

  18. Reduced dose measurement of absolute myocardial blood flow using dynamic SPECT imaging in a porcine model

    Energy Technology Data Exchange (ETDEWEB)

    Timmins, Rachel; Klein, Ran; Petryk, Julia; Marvin, Brian; Kemp, Robert A. de; Ruddy, Terrence D.; Wells, R. Glenn, E-mail: gwells@ottawaheart.ca [Division of Cardiology, University of Ottawa Heart Institute, Ottawa, Ontario K1Y4W7 (Canada); Wei, Lihui [Nordion, Inc., Ottawa, Ontario K2K 1X8 (Canada)

    2015-09-15

    Purpose: Absolute myocardial blood flow (MBF) and myocardial flow reserve (MFR) measurements provide important additional information over traditional relative perfusion imaging. Recent advances in camera technology have made this possible with single-photon emission tomography (SPECT). Low dose protocols are desirable to reduce the patient radiation risk; however, increased noise may reduce the accuracy of MBF measurements. The authors studied the effect of reducing dose on the accuracy of dynamic SPECT MBF measurements. Methods: Nineteen 30–40 kg pigs were injected with 370 + 1110 MBq of Tc-99m sestamibi or tetrofosmin or 37 + 111 MBq of Tl-201 at rest + stress. Microspheres were injected simultaneously to measure MBF. The pigs were imaged in list-mode for 11 min starting at the time of injection using a Discovery NM 530c camera (GE Healthcare). Each list file was modified so that 3/4, 1/2, 1/4, 1/8, 1/16, and 1/32 of the original counts were included in the projections. Modified projections were reconstructed with CT-based attenuation correction and an energy window-based scatter correction and analyzed with FlowQuant kinetic modeling software using a 1-compartment model. A modified Renkin-Crone extraction function was used to convert the tracer uptake rate K1 to MBF values. The SPECT results were compared to those from microspheres. Results: Correlation between SPECT and microsphere MBF values for the full injected activity was r ≥ 0.75 for all 3 tracers and did not significantly degrade over all count levels. The mean MBF and MFR and the standard errors in the estimates were not significantly worse than the full-count data at 1/4-counts (Tc99m-tracers) and 1/2-counts (Tl-201). Conclusions: Dynamic SPECT measurement of MBF and MFR in pigs can be performed with 1/4 (Tc99m-tracers) or 1/2 (Tl-201) of the standard injected activity without significantly reducing accuracy and precision.

  19. Fasting and nonfasting iodine-123-idophenylpentadecanoic acid myocardial SPECT imaging in coronary artery disease.

    Science.gov (United States)

    Heller, G V; Iskandrian, A E; Orlandi, C; Ahlberg, A W; Heo, J; Mann, A; White, M P; Gagnon, A; Taillefer, R

    1998-12-01

    Iodine-123-labeled idophenylpentadecanoic acid (IPPA) metabolic imaging has been shown to be clinically useful for the identification of myocardial viability in patients with coronary artery disease and left ventricular dysfunction. Imaging is usually performed under fasting conditions since nonfasting conditions may affect myocardial uptake of 123I-IPPA. The purpose of this study was to examine the impact of dietary condition on 123I-IPPA metabolic imaging. Forty patients with stable coronary artery disease underwent, in randomized order and on separate days, 123I-IPPA SPECT myocardial imaging under fasting and nonfasting conditions. Patients were injected with 123I-IPPA (4-5 mCi) at rest with imaging performed at 4 (initial) and 30 (delay) min. For each image (initial and delay images), 10 segments were analyzed by three experienced observers without knowledge of patient identity or dietary condition using a 5-point grading system (O = no uptake to 4 = normal uptake). A summed global score was obtained for each image by adding the scores for all 10 segments. Image quality was assessed using a 3-point grading system. Visual agreement for normal and abnormal segments between fasting and nonfasting conditions was 82% (kappa = 0.63). There were no significant differences in the summed global scores for both conditions. Image quality was equivalent for both conditions in 65% of cases and superior under the nonfasting condition in 25% of cases. Image quality as well as the presence, location and severity of defects are similar under fasting and nonfasting conditions with 123I-IPPA. Therefore, fasting is not necessary before 123I-IPPA SPECT imaging for the assessment of myocardial viability.

  20. Development of a New Cardiac and Torso Phantom for Verifying the Accuracy of Myocardial Perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto; Tomoaki [Dept. of Radiological Science, School of Health Science, International University of Health and Welfare, Otawara(Japan); Kim, Jung Min; Lee, Ki Sung [Dept. of Radiological Science, College of Health Science, Korea University, Seoul (Korea, Republic of); Takayama, Teruhiko [Dept. of Clinical Laboratory Science, Graduate School of Medicine, Kanazawa University, Kanazawa (Japan); Kitashi, Kitahara [Dept. of Radiology, Fujigaoka Hospital, Showa University, Tokyo (Korea, Republic of)

    2008-12-15

    Corrections of attenuation, scatter and resolution are important in order to improve the accuracy of single photon emission computed tomography (SPECT) image reconstruction. Especially, the heart movement by respiration and beating cause the errors in the corrections. Myocardial phantom is used to verify the correction methods, but there are many different parts in the current phantoms in actual human body. Therefore the results using a phantom are often considered apart from the clinical data. We developed a new phantom that implements the human body structure around the thorax more faithfully. The new phantom has the small mediastinum which can simulate the structure in which the lung adjoins anterior, lateral and apex of myocardium. The container was made of acrylic and water-equivalent material was used for mediastinum. In addition, solidified polyurethane foam in epoxy resin was used for lung. Five different sizes of myocardium were developed for the quantitative gated SPECT (QGS). The septa of all different cardiac phantoms were designed so that they can be located at the same position. The proposed phantom was attached with liver and gallbladder, the adjustment was respectively possible for the height of them. The volumes of five cardiac ventricles were 150.0, 137.3, 83.1, 42.7 and 38.6 ml respectively. The SPECT were performed for the new phantom, and the differences between the images were examined after the correction methods were applied. The three-dimensional tomography of myocardium was well reconstructed, and the subjective evaluations were done to show the difference among the various corrections. We developed the new cardiac and torso phantom, and the difference of various corrections was shown on SPECT images and QGS results.

  1. Subendocardial versus transmural ischaemia in myocardial perfusion SPECT--a Monte Carlo study.

    Science.gov (United States)

    Bartosik, Jolanta; El-Ali, Henrik Hussein; Nilsson, Ulf; Dahlström, Jan; Edenbrandt, Lars; Ljungberg, Michael

    2006-11-01

    Myocardial perfusion imaging with single-photon emission computed tomography (SPECT) is useful for the evaluation of patients with known or suspected coronary artery disease. Parameters of interest are the reduction in the blood perfusion (severity) and the lesion volume (extent). The aim of this study was to evaluate these parameters, as calculated by automatic quantification software, for different cases of subendocardial and transmural myocardial lesions. A computer phantom was used to simulate 32 male patients with different defect locations and activity uptakes, which were based on clinical patient studies. The Monte Carlo program SIMIND was used to simulate realistic SPECT projections which were reconstructed to give short-axis images, analysed by the AutoQUANT program using the same procedure as for a real patient. The results showed a disparity between the quantification of transmural and subendocardial lesions with the same lesion activity uptake reduction and this could be confirmed by visual interpretation. Neither the parameters given by the quantification program nor visual interpretation could distinguish between the transmural lesions and the subendocardial lesions with activity uptake reduction twice as high as in the corresponding transmural lesions. Transmural lesions and the corresponding subendocardial lesions with the same activity uptake reduction could be separated by the quantification software for SPECT imaging and visual analysis. The subendocardial lesions with activity uptake reduction twice as high as in the corresponding transmural lesions could not be differentiated neither by the quantification software nor by visual interpretation. Thus these lesions will get the same scoring when analysed by the AutoQUANT program.

  2. A new method of detecting subendocardial ischemia in patients with aortic valvular stenosis without coronary artery disease using thallium-201 single photon emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Umamoto, Ikuo; Sugihara, Hiroki; Harada, Yoshiaki (Kyoto Prefectural Univ. of Medicine (Japan)) (and others)

    1993-02-01

    The purpose of this study was to detect myocardial ischemia in aortic valvular stenosis (AVS) without coronary artery disease by using exercise Tl-201 SPECT. The subjects were 18 AVS patients. Twenty other patients were served as controls. Transient 'left ventricular subendocardial dilation and decreased wall thickness', obtained on early SPECT images, were quantitatively determined by transient dilation index (TDI). Washout rates (WR) were calculated from overlapping early and delayed images to obtain WR map. According to TDI, 18 AVS patients were classified as having TDI[<=]1.11 (Group A, n=9) and TDI>1.11 (Group B, n=9). WR map in Group B presented the direction from the pericardial toward the endocardial side, revealing a pattern of decreased WR and a decreased coronary flow reserve on the endocardial side. Both pressure gradient between the aorta and left ventricle and left ventricular wall thickness were significantly greater in Group B than Group A. In 3 patients in Group B, TDI returned to normal and WR map became homogeneous after aortic valve replacement. In addition, fibrosis was noted in the endocardial site on biopsy. In AVS associated with great pressure gradient, endocardial ischemia may occur on exercise, resulting from a decreased coronary flow reserve, and a decreased compliance due to fibrosis and hypertrophy. Exercise Tl-201 myocardial SPECT is capable of detecting distribution patterns of subendocardial ischemia and coronary flow reserve in AVS. (N.K.).

  3. Development and validation of a patient-tailored dose regime in myocardial perfusion imaging using czt-spect

    NARCIS (Netherlands)

    van Dijk, Joris David; van Dijk, J.D.; Iskandrian, A.; de Jager, P.L.; Mouden, M.; Slump, Cornelis H.; Ottervanger, J.P.; Boer, J.; Oostdijk, A.H.J.; van Dalen, J.A.

    2014-01-01

    Background: Guidelines for SPECT myocardial perfusion imaging (MPI) traditionally recommend a fixed tracer dose. Yet, clinical practice shows degraded image quality in heavier patients. The aim was to optimize and validate the tracer dose and scan time to obtain a constant image quality less

  4. Estimation of myocardial perfusion and viability using simultaneous 99mTc-tetrofosmin--FDG collimated SPECT.

    Science.gov (United States)

    Fukuchi, K; Katafuchi, T; Fukushima, K; Shimotsu, Y; Toba, M; Hayashida, K; Takamiya, M; Ishida, Y

    2000-08-01

    This study was designed to elucidate the usefulness of crosstalk correction for dual-isotope simultaneous acquisition (DISA) with 99mTc-tetrofosmin and FDG in estimating myocardial perfusion and viability. Eighteen patients with coronary artery disease were studied. First, SPECT was performed with a low-energy high-resolution collimator after a single injection of 99mTc-tetrofosmin (single 99mTc-tetrofosmin). Second, PET and DISA with an ultra-high-energy collimator were performed after glucose loading and an injection of FDG. DISA was designed to operate with simultaneous 3-channel acquisition, and weighted scatter correction of crosstalk from the 18F photopeak to the 99mTc photopeak was performed by modification of an existing dual-window technique. The FDG SPECT images were compared with the images obtained by PET. Both crosstalk-corrected and uncorrected 99mTc-tetrofosmin images were generated and compared with the single 99mTc-tetrofosmin images. Regional percentage uptake of FDG agreed well between DISA and PET. However, regional percentage uptake of 99mTc-tetrofosmin was generally higher on the uncorrected 99mTc-tetrofosmin images than on the single 99mTc-tetrofosmin images, especially in areas of low flow (percentage count of 99mTc-tetrofosmin > or = 50%). The crosstalk correction contributed to improving the agreement between regional percentage uptakes and significantly improved the detectability of myocardial perfusion-metabolism mismatching. With 3-channel acquisition and weighted-scatter correction of crosstalk from the 18F photopeak to the 99mTc photopeak, DISA with 99mTc-tetrofosmin and FDG is feasible for assessing regional myocardial perfusion and viability.

  5. SPECT myocardial blood flow quantitation toward clinical use: a comparative study with {sup 13}N-Ammonia PET myocardial blood flow quantitation

    Energy Technology Data Exchange (ETDEWEB)

    Hsu, Bailing [University of Missouri-Columbia, Nuclear Science and Engineering Institute, Columbia, Missouri (United States); Hu, Lien-Hsin; Yang, Bang-Hung; Ting, Chien-Hsin; Huang, Wen-Sheng [Taipei Veterans General Hospital, Department of Nuclear Medicine, Taipei (China); Chen, Lung-Ching [Shin Kong Wu-Ho Su Memorial Hospital, Division of Cardiology, Taipei (China); Chen, Yen-Kung [Shin Kong Wu-Ho Su Memorial Hospital, Department of Nuclear Medicine, Taipei (China); Hung, Guang-Uei [Chang Bing Show Chwan Memorial Hospital, Department of Nuclear Medicine, Changhua (China); Wu, Tao-Cheng [National Yang-Ming University, Cardiovascular Research Center, Taipei (China)

    2017-01-15

    The aim of this study was to evaluate the accuracy of myocardial blood flow (MBF) quantitation of {sup 99m}Tc-Sestamibi (MIBI) single photon emission computed tomography (SPECT) compared with {sup 13}N-Ammonia (NH3) position emission tomography (PET) on the same cohorts. Recent advances of SPECT technologies have been applied to develop MBF quantitation as a promising tool to diagnose coronary artery disease (CAD) for areas where PET MBF quantitation is not available. However, whether the SPECT approach can achieve the same level of accuracy as the PET approach for clinical use still needs further investigations. Twelve healthy volunteers (HVT) and 16 clinical patients with CAD received both MIBI SPECT and NH3 PET flow scans. Dynamic SPECT images acquired with high temporary resolution were fully corrected for physical factors and processed to quantify K1 using the standard compartmental modeling. Human MIBI tracer extraction fraction (EF) was determined by comparing MIBI K1 and NH3 flow on the HVT group and then used to convert flow values from K1 for all subjects. MIBI and NH3 flow values were systematically compared to validate the SPECT approach. The human MIBI EF was determined as [1.0-0.816*exp(-0.267/MBF)]. Global and regional MBF and myocardial flow reserve (MFR) of MIBI SPECT and NH3 PET were highly correlated for all subjects (global R{sup 2}: MBF = 0.92, MFR = 0.78; regional R{sup 2}: MBF ≥ 0.88, MFR ≥ 0.71). No significant differences for rest flow, stress flow, and MFR between these two approaches were observed (All p ≥ 0.088). Bland-Altman plots overall revealed small bias between MIBI SPECT and NH3 PET (global: ΔMBF = -0.03Lml/min/g, ΔMFR = 0.07; regional: ΔMBF = -0.07 - 0.06, ΔMFR = -0.02 - 0.22). Quantitation with SPECT technologies can be accurate to measure myocardial blood flow as PET quantitation while comprehensive imaging factors of SPECT to derive the variability between these two approaches were fully addressed and corrected

  6. Iterative deconvolution of simultaneous 99mTc and 201Tl projection data measured on a CdZnTe-based cardiac SPECT scanner.

    Science.gov (United States)

    Kacperski, Krzysztof; Erlandsson, Kjell; Ben-Haim, Simona; Hutton, Brian F

    2011-03-07

    We present a method of correcting self-scatter and crosstalk effects in simultaneous technetium-99m/thallium-201 stress/rest myocardial perfusion (single photon emission computed tomography) SPECT scans. The method, which is in essence a hybrid between the triple energy window method and scatter modelling, is based on a model of spatial and spectral distribution of projection counts in several selected energy windows. The parameters of the model are determined from measurements of thin rod sources in air when no in-object scatter or attenuation effects are present. The model equations are solved using the iterative maximum likelihood expectation maximization algorithm in the projection space to find estimates of the primary photopeak counts of both radionuclides. The method has been developed particularly for a novel dedicated cardiac camera based on CdZnTe pixellated detectors, although it can also be adapted to a conventional scintillator camera. The method has been validated in anthropomorphic phantom experiments. Significant improvement in defect contrast has been observed with only moderate increase in image noise. The application of the method to patient data is illustrated.

  7. Iterative deconvolution of simultaneous 99mTc and 201Tl projection data measured on a CdZnTe based cardiac SPECT scanner

    Science.gov (United States)

    Kacperski, Krzysztof; Erlandsson, Kjell; Ben-Haim, Simona; Hutton, Brian F.

    2011-01-01

    We present a method of correcting self-scatter and crosstalk effects in simultaneous technetium-99m/thallium-201 stress/rest myocardial perfusion SPECT scans. The method, which is in essence a hybrid between the TEW method and scatter modelling, is based on a model of spatial and spectral distribution of projection counts in several selected energy windows. The parameters of the model are determined from measurements of thin rod sources in air when no in-object scatter or attenuation effects are present. The model equations are solved using the iterative Maximum Likelihood Expectation Maximisation (ML-EM) algorithm in the projection space to find estimates of the primary photopeak counts of both radionuclides. The method has been developed particularly for a novel dedicated cardiac camera based on CdZnTe pixellated detectors, although it can also be adapted to a conventional scintillator camera. The method has been validated in anthropomorphic phantom experiments. Significant improvement in defect contrast has been observed with only moderate increase in image noise. The application of the method to patient data is ilustrated. PMID:21317483

  8. Myocardial perfusion abnormalities in asymptomatic patients with systemic lupus erythematosus

    Energy Technology Data Exchange (ETDEWEB)

    Hosenpud, J.D.; Montanaro, A.; Hart, M.V.; Haines, J.E.; Specht, H.D.; Bennett, R.M.; Kloster, F.E.

    1984-08-01

    Accelerated coronary artery disease and myocardial infarction in young patients with systemic lupus erythematosus is well documented; however, the prevalence of coronary involvement is unknown. Accordingly, 26 patients with systemic lupus were selected irrespective of previous cardiac history to undergo exercise thallium-201 cardiac scintigraphy. Segmental perfusion abnormalities were present in 10 of the 26 studies (38.5 percent). Five patients had reversible defects suggesting ischemia, four patients had persistent defects consistent with scar, and one patient had both reversible and persistent defects in two areas. There was no correlation between positive thallium results and duration of disease, amount of corticosteroid treatment, major organ system involvement or age. Only a history of pericarditis appeared to be associated with positive thallium-201 results (p less than 0.05). It is concluded that segmental myocardial perfusion abnormalities are common in patients with systemic lupus erythematosus. Whether this reflects large-vessel coronary disease or small-vessel abnormalities remains to be determined.

  9. Assessment of myocardial perfusion and function in victims of scorpion envenomation using gated-SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Figueiredo, Alexandre Baldini de; Cupo, Palmira; Pintya, Antonio O.; Caligaris, Fabio; Marin-Neto, Jose A; Hering, Sylvia E.; Simoes, Marcus Vinicius, E-mail: simoesmv@yahoo.co [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Hospital das Clinicas

    2010-04-15

    Background: cardiogenic shock and acute pulmonary edema are the major causes of death of patients with scorpion envenomation, whose pathophysiological mechanism remains controversial. Objective: to investigate the correlation between myocardial perfusion abnormalities and left ventricular contractile function in victims of scorpion envenomation. Methods: fifteen patients underwent ECG-gated myocardial perfusion scintigraphy (gated SPECT) within 72 hours of, and 15 days after scorpion envenomation. Images were analyzed by means of a semi-quantitative visual perfusion score (0 = normal, 4 = absent) and motion score (0 = normal, 4 akinesia), using the 17-segment model. Summed perfusion (SPS) and summed motion (SMS) scores were calculated for each patient. Ejection fraction (LVEF) was calculated by a commercially available software. Results: at baseline, 12 out of the 15 patients presented abnormal myocardial perfusion and contractility. Mean values of SPS, SMS and LVEF were 12.5 +- 7.3, 17.0 +- 12.8, and 44.6 +- 16.0%, respectively. A positive correlation between SPS and SMS (r = 0.68; p = 0.005) and negative correlation between SPS and LVEF (r -0.75; p = 0.0021) were found. The follow-up studies showed recovery of global contractility (LVEF of 68.9 +- 9.5, p = 0.0002), segmental contractility (SMS of 2.6 +- 3.1, p = 0.0009) and perfusion (SPS of 3.7 +- 3.3, p = 0.0003). Improvement of LVEF correlated positively with improvement of SPS (r = 0.72; p = 0.0035). Conclusions: myocardial perfusion abnormalities are common in scorpion envenomation and correlate topographically with the contractile dysfunction. Recovery of contractility correlates with reversibility of perfusion defects. These findings suggest the participation of myocardial perfusion abnormalities in the pathophysiology of this form of acute ventricular failure. (author)

  10. Diagnostic value of Tc-99m sestamibi gated SPECT to assess viability in a patient after acute myocardial infarction.

    Science.gov (United States)

    Hambye, A S; Van Den Branden, F; Vandevivere, J

    1996-01-01

    The case of a 56-year-old woman who was admitted with an acute anteroseptal myocardial infarction showed severely decreased left ventricular function and regional wall motion abnormalities on planar Tc-99m gated blood pool imaging. Tc-99m sestamibi stress SPECT imaging demonstrated residual peri-infarct ischemia. At angiography, a solitary severe proximal left anterior descending stenosis was successfully dilated. Later, because of recurrent chest pain, a second Tc-99m sestamibi stress-rest SPECT was performed to exclude restenosis. Because the question of viability within the infarct region had also been asked, a gated protocol was applied and compared to TI-201 rest-redistribution SPECT. Both tests pointed to the existence of tissue viability in the septal region, without evidence for stress ischemia. The patient was then medically treated. One year later, because of angina, Tc-99m gated SPECT blood pool imaging showed a spectacular increase in left ventricular function and a dramatic improvement in regional wall motion. Angiographic data confirmed these findings and there was no significant restenosis. Thus, Tc-99m sestamibi gated SPECT may be helpful in predicting viability and recovery of function in patients with severely impaired left ventricular regional wall motion after acute myocardial infarction.

  11. DIAGNOSTIC VALUE of Tc-99m TETROFOSMİN GATED SPECT IN MYOCARDIAL VIABILITY INVESTIGATION AFTER ADMINISTRATION TRIMETAZIDINE and NITRATE IN THE PATIENTS WITH MYOCARDIAL INFARCTION

    OpenAIRE

    TURHAL, Özgül; TUTUŞ, Ahmet; KULA, Mustafa

    2018-01-01

    ABSTRACT Aim: With the aim of investigating of the myocardial viability on the patients with MI, the results obtained from Tc-99m-tetrofosmin gated SPECT following the nitrate infusion and acute TMZ were compared.Method: For this study, 30 patients who had MI and were be planned of revascularization process were taken. The patients were applied Tc-99m-tetrofosmin gated SPECT basally and following nitrate infusion and acute TMZ separately each day. The data from perfusion were quantitatively e...

  12. Measurement of left ventricular chamber and myocardial volume in hypertrophic cardiomyopathy patients by ECG-gated myocardial perfusion SPECT. Application of a newly developed edge-detection algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, Yoshihiro; Katafuchi, Tetsuro; Hirase, Yoshinori; Sagoh, Masayoshi; Oka, Hisashi [National Cardiovascular Center, Suita, Osaka (Japan); Mori, Hideaki [Siemens-Asahi Medical Technologies, Ltd., Tokyo (Japan); Murase, Kenya [Osaka Univ., Suita (Japan). Medical School

    2002-12-01

    Quantitative gated SPECT (QGS) software has been reported to demonstrate inaccurate edge detection in the left ventricular chamber in hypertrophic cardiomyopathy patients. In this study we developed a method to calculate left ventricular volume (LVV) and left myocardial volume (LMV) from gated SPECT data using a newly developed edge-detection algorithm, and we compared it with the QGS method of calculating LVV and LMV in a phantom study. Our method gave more accurate measurements LVV and LMV whereas the QGS method underestimated LMV. Compared with QGS LVV and LMV, our method yielded better results in the phantom study. (author)

  13. Application of Artificial Neural Network to Computer-Aided Diagnosis of Coronary Artery Disease in Myocardial SPECT Bull's-eye Images

    National Research Council Canada - National Science Library

    Fujita, Hiroshi; Katafuchi, Tetsuro; Uehara, Toshiisa; Nishimura, Tsunehiko

    1992-01-01

    .... The technique employs a neural network to analyze 201 Tl myocardial SPECT bull's-eye images. This multi-layer feed-forward neural network with a backpropagation algorithm has 256 input units (pattern...

  14. Minimizing patient-specific tracer dose in myocardial perfusion imaging using CZT SPECT.

    Science.gov (United States)

    van Dijk, Joris D; Jager, Pieter L; Ottervanger, Jan Paul; Slump, Cornelis H; de Boer, Jaep; Oostdijk, Adrianus H J; van Dalen, Jorn A

    2015-03-01

    Myocardial perfusion imaging (MPI) with SPECT is widely adopted in clinical practice but is associated with a relatively high radiation dose. The aim of this study was to determine the minimum product of tracer dose and scan time that will maintain diagnostic value for cadmium zinc telluride (CZT) SPECT MPI. Twenty-four patients underwent clinically indicated stress MPI using CZT SPECT and a body weight-dependent (3 MBq/kg) (99m)Tc-tetrofosmin tracer dose. Data were acquired for 8 min in list mode. Next, images were reconstructed using 2-, 4-, 6-, and 8-min time frames. Differences between the 8-min reference scan and the shorter scans were determined in segmental uptake values (using the 17-segment cardiac model), ejection fraction, and end-diastolic volume. A 5% difference in segmental uptake was considered to significantly influence the diagnostic value. Next, the quality of the 4-, 6-, and 8-min scans was scored on a 4-point scale by consensus by 3 experienced nuclear medicine physicians. The physicians did not know the scan time or patient information. Differences in segmental uptake values, ejection fraction, and end-diastolic volume were greater for shorter scans than for the 8-min reference scan. On average, the diagnostic value was influenced in 7.7 segments per patient using the 2-min scans, in comparison to 2.0 and 0.8 segments per patient using the 4- and 6-min scans, respectively. In addition, the 4-min scans led to a significantly reduced image quality compared with the 8-min scans (P < 0.05). This was not the case for the 6-min scan. Six minutes was the shortest acquisition time in stress MPI using CZT SPECT that did not affect the diagnostic value for a tracer dose of 3 MBq/kg. Hence, the patient-specific product of tracer dose and scan time can be reduced to a minimum of 18 MBq·min/kg, which may lower the effective radiation dose for patients to values below 1 mSv. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  15. Evaluation of myocardial CT perfusion in patients presenting with acute chest pain to the emergency department: comparison with SPECT-myocardial perfusion imaging.

    Science.gov (United States)

    Feuchtner, Gudrun Maria; Plank, Fabian; Pena, Constantino; Battle, Juan; Min, James; Leipsic, Jonathon; Labounty, Troy; Janowitz, Warren; Katzen, Barry; Ziffer, Jack; Cury, Ricardo C

    2012-10-01

    To determine whether evaluation of resting myocardial CT perfusion (CTP) from coronary CT angiography (CTA) datasets in patients presenting with chest pain (CP) to the emergency department (ED), might have added value to coronary CTA. 76 Patients (age 54.9 y±13; 32 (42%) women) presenting with CP to the ED underwent coronary 64-slice CTA. Myocardial perfusion defects were evaluated for CTP (American Heart Association 17-segment model) and compared with rest sestamibi single-photon emission CT myocardial perfusion imaging (SPECT-MPI). CTA was assessed for >50% stenosis per vessel. CTP demonstrated a sensitivity of 92% and 89%, specificity of 95% and 99%, positive predictive value (PPV) of 80% and 82% and negative predictive value (NPV) of 98% and 99% for each patient and for each segment, respectively. CTA showed an accuracy of 92%, sensitivity of 70.4%, specificity of 95.5%, PPV 67.8%, and NPV of 95% compared with SPECT-MPI. When CTP findings were added to CTA the PPV improved from 67% to 90.1%. In patients presenting to the ED with CP, the evaluation of rest myocardial CTP demonstrates high diagnostic performance as compared with SPECT-MPI. Addition of CTP to CTA improves the accuracy of CTA, primarily by reducing rates of false-positive CTA.

  16. Utility of the combination of DAT SPECT and MIBG myocardial scintigraphy in differentiating dementia with Lewy bodies from Alzheimer's disease

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, Soichiro; Hirao, Kentaro; Kanetaka, Hidekazu; Namioka, Nayuta; Hatanaka, Hirokuni; Hirose, Daisuke; Fukasawa, Raita; Umahara, Takahiko; Sakurai, Hirohumi; Hanyu, Haruo [Tokyo Medical University, Department of Geriatric Medicine, Shinjuku-ku, Tokyo (Japan)

    2016-01-15

    {sup 123}I-2β-Carbomethoxy-3β-(4-iodophenyl)-N-(3-fluoropropyl) nortropane ({sup 123}I-FP-CIT) dopamine transporter single photon emission computed tomography (DAT SPECT) and {sup 123}I-metaiodobenzylguanidine (MIBG) myocardial scintigraphy can be used to assist in the diagnosis of patients with dementia with Lewy bodies (DLB). We compared the diagnostic value of these two methods in differentiating DLB from Alzheimer's disease (AD). Furthermore, we evaluated whether a combination of DAT SPECT and MIBG myocardial scintigraphy would provide a more useful means of differentiating between DLB and AD. Patients with AD (n = 57) and patients with DLB (n = 76) who underwent both DAT SPECT and MIBG myocardial scintigraphy were enrolled. The sensitivity, specificity, and accuracy of both methods as well as their combination for differentiating DLB from AD were calculated. Moreover, we examined whether symptoms of the patients with DLB were associated with the patterns of the abnormalities displayed on DAT SPECT and MIBG myocardial scintigraphy. The sensitivity and specificity of differentiating DLB from AD were 72.4 and 94.4 % by the heart to mediastinum ratio of MIBG uptake, 88.2 and 88.9 % by the specific binding ratio on DAT SPECT, and 96.1 and 90.7 % by their combination, respectively. The combined use of DAT SPECT and MIBG myocardial scintigraphy enabled more accurate differentiation between DLB and AD compared with either DAT SPECT or MIBG myocardial scintigraphy alone. There was a significantly higher frequency of parkinsonism in the abnormal DAT SPECT group than the normal DAT SPECT group. On the other hand, there was a higher frequency of the appearance of rapid eye movement (REM) sleep behavior disorder in the abnormal MIBG uptake group than the normal MIBG uptake group. These results suggested that using a combination of these scintigraphic methods is a useful and practical approach to differentiate DLB from AD. (orig.)

  17. Recent advances of {sup 123}I-BMIPP myocardial SPECT for evaluating ischemic heart disease and cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, T. [Tracer Kinetics and Nuclear Medicine, Osaka Univ., Medical School (Japan)

    1998-12-31

    Recent advances of {sup 123}I-BMIPP myocardial SPECT for evaluating ischemic heart disease and cardiomyopathy were reviewed. The dissociation between BMIPP and thallium defects was frequently observed in patients with acute myocardial infarction with successful reperfusion. The degree and improvement of perfusion/metabolism mismatch may reflect subsequent recovery from postischemic wall motion abnormality. BMIPP myocardial SPECT is also sensitive for detecting myocardial ischemia in acute coronary syndrome. BMIPP defects were observed at sites that corresponded to hypertrophic cardiomyopathy. On the other hand, the dissociation between BMIPP and thallium defects was not observed frequently in dilated cardiomyopathy. However, the heart to the mediastinum ratio and defect score were significantly decreased after coenzyme Q10 treatment. It was confirmed to be sensitive in evaluating the therapeutic effect. Furthermore, the basic mechanisms of BMIPP uptake were also reviewed in relation to BMIPP metabolism and longchain fatty acid transporter (CD36). (orig.) [Deutsch] Es wird eine Uebersicht ueber neueste Entwicklungen der {sup 123}I-BMIPP-Myokard-SPECT fuer die Diagnostik ischaemischer Herzerkrankungen und der Kardiomyopathie praesentiert. Regelmaessig wurde eine Dissoziation zwischen BMIPP- und Thallium-Defekten bei Patienten mit akutem Myokardinfarkt und erfolgreicher Reperfusion beobachtet. Die BMIPP-Aufnahme ist also im erfolgreich therapierten Myokard unmittelbar nach der Reperfusion gestoert, obwohl die Durchblutung wiederhergestellt wurde. Der Grad und die Entwicklung der Perfusions-Stoffwechsel-Mismatche repraesentieren eine spaetere Erholung von der postischaemischen Wandbewegungsstoerung. Die Ruhe-BMIPP-SPECT ist ein sehr sensitives Verfahren, um die Myokardischaemie beim akuten Koronarsyndrom zu erfassen. Diese Methoden sind unter dem Aspekt der Myokardvitalitaet beim Notfallpatienten fuer das Patientenmanagement wertvoll. In 80% der Patienten mit

  18. Myocardial Perfusion SPECT Imaging in Dextrocardia with Situs Inversus: A Case Report.

    Science.gov (United States)

    Ayeni, Olusegun Akinwale; Malan, Nico; Hammond, Emmanuel Niiboye; Vangu, Mboyo-Di-Tamba Heben

    2016-01-01

    Dextrocardia is a cardiac positional anomaly in which the heart is located in the right hemithorax with its base-to-apex axis directed to the right and caudad. Situs inversus is an autosomal recessive disorder that causes organs in the chest and abdomen to be positioned in a mirror image from their normal position. Dextrocardia may occur in isolation or as part of situs inversus. Similarly, situs inversus may occur with or without dextrocardia. Situs inversus accompanied with dextrocardia (situs inversus totalis) is a rare congenital abnormality occurring in 0.01% of live births. Herein, we present the case of a 35-year-old man with previously diagnosed situs inversus totalis with mirror-image dextrocardia, referred to our facility for diagnosis of coronary artery disease (CAD). The incidence and presentation of CAD in patients with dextrocardia are similar to the normal population. However, considerable attention should be paid to the acquisition of myocardial perfusion scintigraphy and data processing/analysis in this group of patients. The present case highlights the distinctive applications and potential pitfalls of myocardial perfusion single-photon emission computed tomography (SPECT) imaging in patients with dextrocardia.

  19. Myocardial Perfusion SPECT Imaging in Dextrocardia with Situs Inversus: A Case Report

    Directory of Open Access Journals (Sweden)

    Olusegun Akinwale Ayeni

    2016-07-01

    Full Text Available Dextrocardia is a cardiac positional anomaly in which the heart is located in the right hemithorax with its base-to-apex axis directed to the right and caudad. Situs inversus is an autosomal recessive disorder that causes organs in the chest and abdomen to be positioned in a mirror image from their normal position. Dextrocardia may occur in isolation or as part of situs inversus. Similarly, situs inversus may occur with or without dextrocardia. Situs inversus accompanied with dextrocardia (situs inversus totalis is a rare congenital abnormality occurring in 0.01% of live births. Herein, we present the case of a 35-yearold man with previously diagnosed situs inversus totalis with mirror-image dextrocardia, referred to our facility for diagnosis of coronary artery disease (CAD. The incidence and presentation of CAD in patients with dextrocardiaare similar to the normal population. However, considerable attention should be paid to the acquisition of myocardial perfusion scintigraphy and data processing/analysis in this group of patients. The present case highlights thedistinctive applications and potential pitfalls of myocardial perfusion single photon emission computed tomography (SPECT imaging in patients with dextrocardia.

  20. Evaluation of Patients with Acute Chest Pain Using SPECT Myocardial Perfusion Imaging: Prognostic Implications of Mildly Abnormal Scans.

    Science.gov (United States)

    Goldkorn, Ronen; Naimushin, Alexey; Beigel, Roy; Naimushin, Ekaterina; Narodetski, Michael; Matetzky, Shlomi

    2017-06-01

    While patients presenting to emergency departments (ER) with chest pain are increasingly managed in chest pain units (CPU) that utilize accelerated diagnostic protocols for risk stratification, such as single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI), data are lacking regarding the prognostic implications of mildly abnormal scans in this population. To evaluate the prognostic implications of mildly abnormal SPECT MPI results in patients with acute chest pain. Of the 3753 chest pain patients admitted to the CPU at the Leviev Heart Center, Sheba Medical Center 1593 were further evaluated by SPECT MPI. Scans were scored by extent and severity of stress-induced perfusion defects, with 1221 patients classified as normal, 82 with myocardial infarction without ischemia, 236 with mild ischemia, and 54 with more than mild ischemia. Mild ischemia patients were further classified to those who did and did not undergo coronary angiography within 7 days. Mild ischemia patients who underwent coronary angiography were more likely to be male (92% vs. 81%, P = 0.01) and to have left anterior descending ischemia (67% vs. 42%, P = 0.004). After 50 months, these patients returned less often to the ER with chest pain (53% vs. 87%, P acute coronary syndrome and death (8% vs. 16%, P patients with chronic stable angina, patients presenting with acute chest pain exhibiting mildly abnormal SPECT MPI findings should perhaps undergo a more aggressive diagnostic and therapeutic approach.

  1. Added value of hybrid myocardial perfusion SPECT and CT coronary angiography in the diagnosis of coronary artery disease.

    Science.gov (United States)

    Schaap, Jeroen; de Groot, Joris A H; Nieman, Koen; Meijboom, W Bob; Boekholdt, S Matthijs; Kauling, Robert M; Post, Martijn C; Van der Heyden, Jan A; de Kroon, Thom L; Rensing, Benno J W M; Moons, Karel G M; Verzijlbergen, J Fred

    2014-11-01

    Hybrid single photon emission computed tomography (SPECT)/coronary computed tomography angiography (CCTA) has only been evaluated for its diagnostic accuracy as a single test in patients suspected of significant coronary artery disease (CAD). Added value of hybrid SPECT/CCTA beyond usual clinical work-up, or use of each of these tests separately, remains unclear. We evaluated the added value of hybrid myocardial perfusion SPECT (SPECT) and CCTA, beyond pre-test likelihood and exercise stress ECG (X-ECG), in the diagnosis of CAD. Two hundred and five patients with stable angina pectoris and intermediate-to-high pre-test likelihood were prospectively included. All patients underwent clinical history and examination, X-ECG, stress and rest SPECT, coronary calcium scoring (CCS) and CCTA. Fractional flow reserve measurement 50% on coronary angiography (CA) served as reference standard for significant CAD. Multiple imputation was used to correct for missing test results (17-20%). Added value of hybrid SPECT/CCTA to the basic model of pre-test likelihood plus X-ECG was quantified using logistic regression analysis. Model differences were then assessed using differences in C-index and in net reclassification improvement (NRI). The basic model had a C-index of 0.73 (95%CI 0.66-0.80). This significantly increased to 0.85 (95%CI 0.80-0.91) by addition of only SPECT, to 0.90 (95%CI 0.85-0.94) when adding only CCTA, and to 0.96 (95%CI 0.92-0.99) when adding hybrid SPECT/CCTA. The accompanying NRIs were 0.82 (95%CI 0.62-1.02), 0.86 (95%CI 0.66-1.06) and 1.57 (95%CI 1.11-1.59) respectively. Current analysis resembles clinical routine of layered testing and shows that hybrid SPECT/CCTA imaging has a substantially higher yield than standalone SPECT or CCTA in the diagnostic workup of patients suspected of significant CAD. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  2. Characteristic findings of exercise ECG test, perfusion SPECT and coronary angiography in patients with exercise induced myocardial stunning

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Byeong Cheol; Seo, Ji Hyoung; Bae, Jin Ho; Jeong, Shin Young; Park, Hun Sik; Lee, Jae Tae; Chae, Shung Chull; Lee, Kyu Bo [School of Medicine, Kyungpook National Univ., Daegu (Korea, Republic of)

    2004-06-01

    Transient wall motion abnormality and contractile dysfunction of the left ventricle (LV) can be observed in patients with coronary artery disease due to post-stress myocardial stunning. To understand clinical characteristics of stress induced LV dysfunction, we have compared the findings of exercise stress test, myocardial perfusion SPECT and coronary angiography between subjects with and without post-stress LV dysfunction. Among subjects who underwent exercise stress test, myocardial perfusion SPECT and coronary angiography within a month of interval, we enrolled 36 patients with post-stress LV ejection fraction (LVEF) was {>=}5% lower than rest (stunning group) and 16 patients with difference of post-stress and rest LVEF was lesser than 1% (non-stunning group) for this study. Treadmill exercise stress gated myocardial perfusion SPECT was performed with dual head SPECT camera using 740 MBq Tc-99m MIBI and coronary angiography was also performed by conventional Judkins method. Stunning group had a significantly higher incidence of hypercholesterolemia than non-stunning group(45.5 vs 7.1%, p=0.01). Stunning group also had higher incidence of diabetes mellitus and lower incidence of hypertension, but these were not statistically significant. Stunning group had larger and more severe perfusion defect in stress perfusion myocardial SPECT than non-stunning group(extent 18.2 vs 9.2%, p=0.029; severity 13.5 vs 6.9, p=0.040). Stunning group also had higher degree of reversibility of perfusion defect, higher incidence of positive exercise stress test and higher incidence of having severe stenosis(80{approx}99%) in coronary angiography than non-stunning group, but these were not statistically significant. In stunning group, all of 4 patients without perfusion defect had significant coronary artery stenosis and had received revascularization treatment. Patients with post-stress LV dysfunction had larger and more severe perfusion defect and severe coronary artery stenosis than

  3. The prognostic value of regadenoson SPECT myocardial perfusion imaging in patients with end-stage renal disease.

    Science.gov (United States)

    Doukky, Rami; Fughhi, Ibtihaj; Campagnoli, Tania; Wassouf, Marwan; Ali, Amjad

    2017-02-01

    The prognostic value of regadenoson SPECT myocardial perfusion imaging (MPI) has not been specifically studied in patients with end-stage renal disease (ESRD). We prospectively followed ESRD patients enrolled in the ASSUAGE and ASSUAGE-CKD trials in which they received regadenoson-stress 99m Tc-tetrofosmin SPECT-MPI. Images were semiquantitatively analyzed by an investigator blinded to clinical and outcome data. Patients were followed for cardiac death, myocardial infarction (MI), and coronary revascularization (CR). Revascularizations occurring >90 days post-MPI were considered "late" events. Survival analysis was performed using Cox regression models, adjusting for age, gender, diabetes, dyslipidemia, smoking, and known coronary artery disease. We analyzed 303 patients (mean age 54 years; 64% men), who were followed for 35 ± 10 months. Adjusting for clinical covariates, abnormal regadenoson-stress MPI (SSS ≥ 4) was associated with increased risk of the composite of cardiac death or MI (23.9% vs 14.4%; HR 1.88; CI 1.04-3.41; P = .037) and the composite of cardiac death, MI, or late CR (27.3% vs 16.7%; HR 1.80; CI 1.03-3.14; P = .039). Adjusting for clinical covariates, regadenoson-induced myocardial ischemia (SDS ≥ 2) was associated with increased rate of the composite endpoint of cardiac death, MI, or CR (33.3% vs 16.9%; HR 1.97; CI 1.19-3.27; P = .008). Regadenoson-stress SPECT-MPI provides a significant prognostic value in patients with ESRD. ESRD patients with normal SPECT-MPI have relatively high adverse event rates.

  4. Prognostic Value of Normal Perfusion but Impaired Left Ventricular Function in the Diabetic Heart on Quantitative Gated Myocardial Perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Hwanjeong; Choi, Sehun; Han, Yeonhee [Research Institute of Chonbuk National Univ. Medical School and Hospitial, Jeonju (Korea, Republic of); Lee, Dong Soo; Lee, Hoyoung; Chung, Junekey [Seoul National Univ., Seoul (Korea, Republic of)

    2013-09-15

    This study aimed at identifying the predictive parameters on quantitative gated myocardial perfusion single-photon emission computed tomography (QG-SPECT) in diabetic patients with normal perfusion but impaired function. Methods Among the 533 consecutive diabetic patients, 379 patients with normal perfusion on rest Tl-201/dipyridamole-stress Tc-{sup 99m} sestamibi Gated SPECT were enrolled. Patients were grouped into those with normal post-stress left ventricular function (Group I) and those with impaired function (EF <50 or impaired regional wall motion, Group II). We investigated cardiac events and cause of death by chart review and telephone interview. Survival analysis and Cox proportional hazard model analysis were performed. Between the Group I and II, cardiac events as well as chest pain symptoms, smoking, diabetic complications were significantly different (P<0.05). On survival analysis, event free survival rate in Group II was significantly lower than in Group I (P=0.016). In univariate Cox proportional hazard analysis on overall cardiac event, Group (II over I), diabetic nephropathy, summed motion score (SMS), summed systolic thickening score (STS), numbers of abnormal segmental wall motion and systolic thickening predicted more cardiac events (P<0.05). Multivariate analysis showed that STS was the only independent predictor cardiac event. The functional parameter, especially summed systolic thickening score on QG-SPECT had prognostic values, despite normal perfusion, in predicting cardiac events in diabetic patients, and QG-SPECT provides clinically useful risk stratification in diabetic patients with normal perfusion.

  5. Determination of systolic thickening index with gated Tc-99m sestamibi SPECT. A new parameter of myocardial viability?

    Science.gov (United States)

    Hambÿe, A S; Dobbeleir, A; Derveaux, M; Vandevivere, J; van den Heuvel, P

    1997-03-01

    Myocardial perfusion imaging with Tc-99m MIBI SPECT may underestimate the amount of viable myocardium in patients with coronary artery disease and prior infarction. Electrocardiogram gating could potentially better correlate with the presence of jeopardized myocardium, since it allows the evaluation of systolic contractility parameters in addition to the assessment of perfusion. Using the diastolic and systolic bull's eyes of a rest Tc-99m MIBI-gated SPECT study to generate an index of systolic thickening, we clearly observed an impaired contractility in the anterior and septal walls in a patient with multiple vessel disease and a mild mid-left anterior descending stenosis, despite a normal tracer uptake. Confirmation of the index of systolic thickening findings was obtained by rest/redistribution TI-201 SPECT, showing decreased anteroseptal perfusion on the early images with almost complete perfusion. Gating myocardial perfusion imaging seems helpful to identify myocardium at risk. It can aid in the evaluation of the physiological significance of mild coronary artery disease, sometimes insufficient to result in perceptible flow disturbances but already responsible for contractility abnormalities, especially when a large arterial territory is involved.

  6. Non invasive evaluation of the coronary atherosclerosis illness in patients with silent ischemia: utility of the SPECT of myocardial perfusion. Electric, angiographic and image correlation; Valoracion no invasiva de la enfermedad ateroesclerosa coronaria en pacientes con isquemia silente: utilidad del SPECT de perfusion miocardica. Correlacion electrica, angiografica y de imagen

    Energy Technology Data Exchange (ETDEWEB)

    Puente B, A.; Roffe G, F.; Aceves C, J.; Gomez A, E. [Hospital Centro Medico Nacional 20 de Noviembre, ISSSTE, Mexico D.F. (Mexico)

    2005-07-01

    The objective of the work was to determine the utility of the SPECT (Single Photon Emission Computerized Tomography) of myocardial perfusion for the ischemia detection in asymptomatic patients with Coronary Atherosclerosis Illness. It was concluded that the SPECT of myocardial perfusion has a high sensitivity (97%) for the silent ischemia diagnosis.

  7. Transient ischemic dilation ratio (TID) correlates with HbA(1c) in patients with diabetes type 2 with proven myocardial ischemia according to exercise myocardial SPECT.

    Science.gov (United States)

    Adamikova, Alena; Bakala, Jiri; Bernatek, Jaromir; Rybka, Jaroslav; Svacina, Stepan

    2006-11-01

    Abnormal values of the transient ischemic dilation ratio (TID) according to an exercise myocardial SPECT are linked to severe coronary artery disease. The authors investigated the relationship between TID and the levels of VCAM, ICAM, E-selectin, microalbuminuria, intima-media thickness and HbA(1c) of diabetic subjects. We observed 38 subjects with diabetes type 2 (10 women, 28 men), of average age 56.08 +/- 8.24 years, with no past history of cardiovascular disease. All subjects were examined using an exercise myocardial SPECT. Transient ischemic dilation, summed stress score (SSS), summed rest score (SRS) and stress total severity score (STSS) were determined to quantify myocardial ischemia. The average IMT value was 1.05 +/- 0.31 mm. The TID value was 1.02 +/- 0.154, VCAM 795.24 +/- 163.25 mg/l, ICAM 516.55 +/- 164.07, E-selectin 63.82 +/- 38.89, HbA(1c) 7.09 +/- 1.68%, microalbuminuria 68.01 +/- 55.21 mg/l. When ascertaining the relation of TID to the other factors we used Pearson's correlation at the level of significance p TID and glycosylated hemoglobin HbA(1c) (p = 0.035); the other factors did not show any significant correlation. Diabetes and its long- term unsatisfactory compensation can be one of the factors which affect left ventricular transient ischemic dilation.

  8. Diagnostic value of 123I-phenylpentadecanoic acid (IPPA) metabolic and thallium 201 perfusion imaging in stable coronary artery disease.

    Science.gov (United States)

    Walamies, M; Turjanmaa, V; Koskinen, M; Uusitalo, A

    1993-08-01

    The diagnostic value of 123I-phenylpentadecanoic acid (IPPA) metabolic cardiac imaging was studied in a group (n = 29) of patients with angiographically confirmed CAD using single photon emission computed tomography (SPECT). A symptom-limited exercise test was first done with IPPA, and 2 days later with thallium. Medications were not withheld during testing. Fourteen healthy control subjects participated in parallel IPPA and 15 in thallium tests. Data acquisition and output were comparable in the two imaging modalities. By testing various relatively simple criteria for abnormality we found that the semiquantitative interpretation was more accurate than the visual readings. The best compromise of accuracy with the scored criteria consisted of a sensitivity of 86% and a specificity of 86%, obtained with IPPA polar tomograms (mild exercise defect) and a sensitivity of 86% and a specificity of 80% obtained with thallium (regionally decreased washout). With visual interpretation alone, a sensitivity of 83% and a specificity of 71% was detected with IPPA (mild exercise defect) and 72% and 73%, respectively, with thallium (partial reversibility). The sensitivity of the exercise ECG alone was 62%. The results of this study imply that IPPA imaging could be a rational, uncomplicated clinical method for non-invasive diagnosis of CAD. The diagnostic ability of IPPA is at least as good as that of thallium, and it is possible to use them in succession.

  9. Imaging of brain tumors in AIDS patients by means of dual-isotope thallium-201 and technetium-99m sestamibi single-photon emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    De La Pena, R.C.; Ketonen, L.; Villanueva-Meyer, J. [Dept. of Radiology, Univ. of Texas, Galveston (United States)

    1998-10-01

    Our aim was to evaluate the use of dual-isotope thallium-201 (Tl) and technetium-99m sestamibi (sestamibi) simultaneous acquisition in brain single-photon emission tomography (SPET) for the differentiation between brain lymphoma and benign central nervous system (CNS) lesions in AIDS patients. Thirty-six consecutive patients with enhancing mass lesions on magnetic resonance (MR) imaging were included in the study. SPET of the brain was performed to obtain simultaneous Tl and sestamibi images. Regions-of-interest were drawn around the lesion and on the contralateral side to calculate uptake ratios. The final diagnosis was reached by pathologic findings in 17 patients and clinical and/or MR follow-up in 19 patients. Of the 36 patients, 11 had brain lymphoma, 1 glioblastoma multiforme, 15 toxoplasmosis and 9 other benign CNS lesions. Correlation between SPET and the final diagnosis revealed in 10 true-positive, 23 true-negative, 1 false-positive and 2 false-negative studies. All patients with toxoplasmosis had negative scans. A patient with a purulent infection had positive scans. Tl and sestamibi scans were concordant in every lesion. The same lesions that took up Tl were also visualized with sestamibi. However, sestamibi scans showed higher lesion-to-normal tissue uptake ratios (3.7{+-}1.8) compared with those of Tl (2.3{+-}0.8, P<0.002). Simultaneous acquisition of Tl and sestamibi can help differentiate CNS lymphoma from benign brain lesions in AIDS patients. (orig.) With 2 figs., 2 tabs., 34 refs.

  10. Reverse redistribution of Tc-99m-tetrofosmin in exercise myocardial SPECT in patients with hypertrophic cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Sugihara, Hiroki; Taniguchi, Yoko; Kinoshita, Noriyuki [Kyoto Prefectural Univ. of Medicine (Japan)] [and others

    1998-10-01

    We examined the usefulness of Tc-99m-tetrofosmin in detecting exercise induced perfusion abnormalities in patients with hypertrophic cardiomyopathy (HCM) and to clarify time-related changes in myocardial distribution of Tc-99m-tetrofosmin after a single injection. We studied 44 consecutive patients with HCM by means of exercise/rest Tc-99m-tetrofosmin single photon emission computed tomography (SPECT). After injecting 370 MBq of Tc-99m-tetrofosmin at the peak exercise, the early SPECT imaging was performed at 30 min (EX-30) and the delayed imaging at 180 min (EX-180). Immediately after the delayed imaging, 740 MBq of Tc-99m-tetrofosmin was injected in the resting state, and the rest SPECT imaging was performed 30 min later. Exercise-induced regional perfusion defects and/or apparent reversible left ventricular cavity dilation were identified in 26 (68.2%) of the 44 patients. When EX-30 images and EX-180 images were compared, reverse redistribution was confirmed in 36 patients (81.8%). Reverse redistribution was detected most frequently in the septal portion of the anterior wall, followed by the septal portion of the posterior wall and the septum. Exercise/rest Tc-99m-tetrofosmin myocardial imaging was a useful method for assessing myocardial perfusion abnormalities in patients with HCM. Reverse redistribution was detected very frequently on early and delayed images of exercise. We assumed that reverse redistribution may reflect a retention disorder of Tc-99m-tetrofosmin caused by some metabolic dysfunction of myocytes. (author)

  11. SPECT myocardial perfusion imaging. Long-term prognostic value in diabetic patients with and without coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Koehli, M. [Dept. of Endocrinology, Diabetology and Metabolism, Univ. Hospital Lausanne (Switzerland); Dept. of Nuclear Medicine, Univ. Hospital Lausanne (Switzerland); Monbaron, D.; Gaillard, R.C.; Ruiz, J. [Dept. of Endocrinology, Diabetology and Metabolism, Univ. Hospital Lausanne (Switzerland); Prior, J.O.; Bischof Delaloye, A. [Dept. of Nuclear Medicine, Univ. Hospital Lausanne (Switzerland); Calcagni, M.L. [Dept. of Nuclear Medicine, Univ. Hospital Lausanne (Switzerland); Dept. of Cardiology, Univ. Hospital Lausanne (Switzerland); Fivaz-Arbane, M.; Stauffer, J.C. [Inst. of Nuclear Medicine, Univ. Cattolica del Sacro Cuore, Roma (Italy)

    2006-07-01

    Aim: To determine the long-term prognostic value of SPECT myocardial perfusion imaging (MPI) for the occurrence of cardiovascular events in diabetic patients. Patients, methods: SPECT MPI of 210 consecutive Caucasian diabetic patients were analysed using Kaplan-Meier event-free survival curve and independent predictors were determined by Cox multivariate analyses. Results: Follow-up was complete in 200 (95%) patients with a median period of 3.0 years (0.8-5.0). The population was composed of 114 (57%) men, age 65 {+-} 10 years, 181 (90.5%) type 2 diabetes mellitus, 50 (25%) with a history of coronary artery disease (CAD) and 98 (49%) presenting chest pain prior to MPI. The prevalence of abnormal MPI was 58%. Patients with a normal MPI had neither cardiac death, nor myocardial infarction, independently of a history of coronary artery disease or chest pain. Among the independent predictors of cardiac death and myocardial infarction, the strongest was abnormal MPI (p < 0.0001), followed by history of CAD (Hazard Ratio (HR) = 15.9; p = 0.0001), diabetic retinopathy (HR = 10.0; p = 0.001) and inability to exercise (HR = 7.7; p = 0.02). Patients with normal MPI had a low revascularisation rate of 2.4% during the follow-up period. Compared to normal MPI, cardiovascular events increased 5.2 fold for reversible defects, 8.5 fold for fixed defects and 20.1 fold for the association of both defects. Conclusion: Diabetic patients with normal MPI had on excellent prognosis independently of history of CAD. On the opposite, an abnormal MPI led to a > 5-fold increase in cardiovascular events. This emphasizes the value of SPECT MPI in predicting and risk-stratifying cardiovascular events in diabetic patients. (orig.)

  12. Dual-tracer autoradiography with thallium-201 and iodine-125 MIBG in BIO 14. 6 cardiomyopathic Syrian hamsters

    Energy Technology Data Exchange (ETDEWEB)

    Taguchi, Takahisa; Kobayashi, Akira; Kurata, Chinori; Tawarahara, Kei; Yamazaki, Noboru (Hamamatsu Univ. School of Medicine, Shizuoka (Japan))

    1993-11-01

    Dual-tracer imaging of the heart with [sup 125]I-metaiodobenzylguanidine (MIBG) and [sup 201]Tl can simultaneously demonstrate the distribution of sympathetic nerve endings and the underlying myocardial perfusion. A quantitative dual-tracer autoradiographic study with [sup 201]Tl and [sup 125]I-MIBG was performed to investigate changes in the distribution of cardiac sympathetic innervation with the progression of cardiomyopathy in BIO 14.6 hamsters. The distribution of [sup 201]Tl was uniform in control hamsters and BIO 14.6 hamsters at all stages of cardiomyopathy. In contrast, a reduction in MIBG accumulation occurred in the endocardial region of the left ventricular free wall and the left ventricular aspect of the interventricular septum in BIO 14.6 hamsters at 3 and 8 months of age. Thus, there was an uncoupling of the left ventricular distribution of [sup 201]Tl and [sup 125]I-MIBG in BIO 14.6 hamsters. In addition, interstitial fibrosis was increased in the interventricular septum, the subendocardial region of the left ventricular free wall, and the right ventricular wall, which were the sites of reduced MIBG accumulation. This study shows that dual myocardial imaging with MIBG and [sup 201]Tl may be useful for investigating patients with cardiomyopathy. (author).

  13. Prognosis of patients with positive exercise test and normal myocardial perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Seo, J. H.; Jeong, S. Y.; Bae, J. H.; Ahn, B. C.; Lee, J.; Lee, K. B [College of Medicine, Kyungpook National University, Daegu (Korea, Republic of)

    2004-07-01

    Exercise SPECT myocardial perfusion imaging(Ex-MPI) is regarded as a predictive technique particularly in patients with coronary artery disease(CAD) capable of performing exercise testing. In clinical practice, we encounter equivocal situations of discordant findings between exercise ECG and MPI. We evaluated the prognosis of subjects with positive ECG and normal MPI findings, and predictive factors for cardiac events. 2571 Ex-MPI studies were reviewed over a period of 3 years. Subjects were followed for more than 2 years(24-56 months, mean 35{+-}10months) for cardiac events after study. The cardiac events were defined as hard events(cardiac death and nonfatal myocardial infarction(MI)) and soft events(aggravation of CAD necessitating revascularization, congestive heart failure necessitating hospital admission). We evaluated age, sex, typical angina pain, rest ECG, hypertension, diabetes mellitus(DM), serum levels of cholesterol and LDL, smoking history, history of cerebrovascular disease(CVD) and peripheral artery disease(PAD), and rest left ventricular ejection fraction(LVEF) as clinical variables. Of 83 subjects with positive ECG and normal MPS findings, 6 were considered as false negative results confirmed with coronary angiography. There were 77 patients (mean age 52{+-}10 years, 39 males) with positive ECG and normal MPI results. During the follow-up period, of 77 there were 3 cardiac events (annual rate 1.9%), no cardiac death, 2 nonfatal MIs (annual rate 1.3%) and 1 soft event (annual rate 0.6%). 2/39 males(5.1%), and 1/38 females(2.6%) had cardiac events. All cardiac events were observed within 2 years. 1-year cardiac event rate was 0.6% and 2-year cardiac event rate was 1.9%. Among clinical factors, male sex, typical chest pain and smoking history at the time of MPI were predictive of cardiac events. Patients with positive ECG and negative EX-MPI results have low risk for cardiac events. Nevertheless, the cardiac events cannot be excluded totally in some

  14. Assessment of transient dilation of the left ventricular cavity in patients with hypertrophic cardiomyopathy by exercise thallium-201 scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Sugihara, Hiroki; Shiga, Kouji; Umamoto, Ikuo (Kyoto Prefectural Univ. of Medicine (Japan)) (and others)

    1990-11-01

    Exercise Tl scintigraphy (EX-Tl) provides a noninvasive means of identifying myocardial perfusion abnormalities in patients (pts) with hypertrophic cardiomyopathy (HCM). We have noted that some pts with HCM have a pattern of transient dilation of the left ventricle (LV) on the immediate post exercise images as compared with 3 hour redistribution images. We presumed that left ventricular dilation was caused by subendocardial hypoperfusion. So we studied transient dilation of the LV in 50 pts with HCM and 20 controls (C). Initial and delayed conventional short tomographic images were obtained after reconstruction of 30 projections acquired over 180 degrees. Thirty six radii every 10 degrees were generated from the center of the middle myocardial images of the short axis. An area surrounded by the thirty six points of maximal count on each radius was calculated in initial and delayed images. Transient dilation index (TDI) as an index of dilation was determined by dividing an area in initial image by an area in delayed image. TDI in pts with HCM was larger than that in C. Pts with HCM were classified into the two groups, Group A: TDI>1.11 (mean+2 SD in C), 24 pts, Group B: TDI>1.11, 26 pts. Frequency of pts with history of chest pain in Group A was higher than that in Group B, and frequency of pts with positive exercise ECG in Group A was higher than that in Group B. End diastolic volume in Group B did not change 10 minutes after exercise by radionuclide ventriculography. In conclusion, transient dilation of the LV in pts with HCM by Ex-Tl is in appearance, and may reflect subendocardial ischemia. (author).

  15. Risk stratification using line source attenuation correction with rest/stress Tc-99m sestamibi SPECT myocardial perfusion imaging.

    Science.gov (United States)

    Ardestani, Afrooz; Ahlberg, Alan W; Katten, Deborah M; Santilli, Krista; Polk, Donna M; Bateman, Timothy M; Heller, Gary V

    2014-02-01

    Although line source attenuation correction (AC) in SPECT MPI studies improves diagnostic accuracy, its prognostic value is less understood. Consecutive patients (n = 6,513) who underwent rest/stress AC ECG-gated SPECT MPI were followed for cardiac death or non-fatal myocardial infarction (MI). A 17-segment model and AC summed stress score (SSS) were used to classify images. Of the 6,513 patients, cardiac death or non-fatal MI occurred in 267 (4.1%), over 2.0 ± 1.4 years. The AC-SSS in patients with a cardiac event (5.6 ± 7.8) was significantly higher than in those without (1.9 ± 4.6, P 8 with annualized cardiac event rates of 1.1%, 3.2%, and 8.5%, respectively (P 8 emerged as independent predictors of cardiac events (P stress ECG-gated SPECT MPI with line source AC provides highly effective and incremental risk stratification for future cardiac events.

  16. Hybrid CCTA/SPECT myocardial perfusion imaging findings in patients with anomalous origin of coronary arteries from the opposite sinus and suspected concomitant coronary artery disease.

    Science.gov (United States)

    Gräni, Christoph; Benz, Dominik C; Schmied, Christian; Vontobel, Jan; Mikulicic, Fran; Possner, Mathias; Clerc, Olivier F; Stehli, Julia; Fuchs, Tobias A; Pazhenkottil, Aju P; Gaemperli, Oliver; Buechel, Ronny R; Kaufmann, Philipp A

    2017-02-01

    Anomalous coronary arteries originating from the opposite sinus of Valsalva (ACAOS) are associated with adverse cardiac events. Discrimination between ACAOS and coronary artery disease (CAD)-related perfusion defects may be difficult. The aim of the present study was to investigate the value of hybrid coronary computed tomography angiography (CCTA)/SPECT-MPI in patients with ACAOS and possible concomitant CAD. We retrospectively identified 46 patients (mean age 56 ± 12 years) with ACAOS revealed by CCTA who underwent additional SPECT-MPI. ACAOS with an interarterial course were classified as malignant, whereas all other variants were considered benign. CCTA/SPECT-MPI hybrid imaging findings (ischemia or scar) were analyzed according to the territory subtended by an anomalous vessel or a stenotic coronary artery. Twenty-six (57%) patients presented with malignant ACAOS. Myocardial ischemia or scar was found only in patients who had concomitant obstructive CAD in the vessel matching the perfusion defect as evidenced by hybrid CCTA/SPECT imaging. Hybrid CCTA/SPECT-MPI represents a valuable non-invasive tool to discriminate the impact of ACAOS from concomitant CAD on myocardial ischemia. Our results suggest that in a middle-aged population myocardial ischemia due to ACAOS per se may be exceedingly rare and is more likely attributable to concomitant CAD.

  17. Calculation of variability in myocardial uptake of {sup 99m}Tc-tetrofosmin at exercise and rest SPECT images. Application to hypertrophic cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Nii, Takeshi; Nishida, Takuji; Kakizaki, Junko; Sugahara, Syuji [Kyoto Prefectural Univ. of Medicine (Japan)

    1998-11-01

    We examined whether or not it is better to use delayed myocardial SPECT images in determining the variability in myocardial uptake ({Delta}TF) of {sup 99m}Tc-tetrofosmin under the one-day protocol. We injected 370 MBq of {sup 99m}Tc-tetrofosmin at peak exercise, and initial (TF1) and delayed (TF2) exercise SPECT images were acquired 30 min and 3 hr, respectively, after the injection. Then, 740 MBq of {sup 99m}Tc-tetrofosmin was reinjected soon after TF2 acquisition, and rest SPECT images (TF3) were obtained 30 min later. Myocardial counts of TF1, TF2, and TF3 were defined as C1, C2, and C3, respectively, and {Delta}TF was determined by the following formula: {Delta}TF(A) = ({l_brace}C1 x R-(C3-C2`){r_brace}/(C3-C2`)) x 100(%). {Delta}TF(B) = ({l_brace}C1 x R-(C3-C1`){r_brace}/(C3-C1`)) x 100(%), where R is dose ratio, A is the procedure of imaging with delayed exercise SPECT, and B is the procedure of imaging without delayed exercise SPECT. The combination in which the delayed image was used better clarified the decreased uptake of {sup 99m}Tc-tetrofosmin at the hypertrophied myocardium, and thus proved to be useful. (author)

  18. Comparative value of brain perfusion SPECT and [{sup 123}I]MIBG myocardial scintigraphy in distinguishing between dementia with Lewy bodies and Alzheimer's disease

    Energy Technology Data Exchange (ETDEWEB)

    Hanyu, Haruo; Shimizu, Soichiro; Hirao, Kentaro; Kanetaka, Hidekazu; Iwamoto, Toshihiko [Tokyo Medical University, Department of Geriatric Medicine, Tokyo (Japan); Chikamori, Taishiro; Usui, Yasuhiro; Yamashina, Akira [Tokyo Medical University, 2. Department of Internal Medicine, Tokyo (Japan); Koizumi, Kiyoshi; Abe, Kimihiko [Tokyo Medical University, Department of Radiology, Tokyo (Japan)

    2006-03-15

    Both decreased occipital perfusion on brain single-photon emission computed tomography (SPECT) and reduction in cardiac {sup 123}I-metaiodobenzylguanidine (MIBG) uptake are characteristic features of dementia with Lewy bodies (DLB), and potentially support the clinical diagnosis of DLB. The aim of this study was to compare the diagnostic value of these two methods for differentiation of DLB from Alzheimer's disease (AD). The study population comprised 19 patients with probable DLB and 39 patients with probable AD who underwent both SPECT with N-isopropyl-p-[{sup 123}I]iodoamphetamine and MIBG myocardial scintigraphy. Objective and quantitative measurement of perfusion in the medial occipital lobe, including the cuneus and lingual gyrus, was performed by the use of three-dimensional stereotactic surface projections. Medial occipital perfusion was significantly decreased in the DLB group compared with the AD group. The mean heart/mediastinum ratios of MIBG uptake were significantly lower in the DLB group than in the AD group. Although SPECT failed to demonstrate significant hypoperfusion in the medial occipital lobe in five patients with DLB, marked reduction of MIBG uptake was found in all patients with DLB. Receiver operating characteristic analysis revealed that MIBG myocardial scintigraphy enabled more accurate discrimination between DLB and AD than was possible with perfusion SPECT. MIBG myocardial scintigraphy may improve the sensitivity in the detection of DLB. In particular, this method may provide a powerful differential diagnostic tool when it is difficult to distinguish cases of DLB from AD using brain perfusion SPECT. (orig.)

  19. Effects of potassium channel opener on the kinetics of thallium-201 in in-vitro and in-vivo

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J.; Kim, E. J.; Ahn, B. C.; Chae, S. C.; Lee, K. B. [College of Medicine, Kyungpook National Univ., Taegu (Korea, Republic of); Kim, C. K. [Mt. Sinai Medical School, New York (United States)

    1997-07-01

    Potassium channel opener (K-opener) opens membrane ATP-sensitive K{sup +}-channel and induces and increase in potassium efflux from cells. K-openers are powerful smooth muscle relaxants and currently used as antihypertensive, antianginal drugs or bronchodilators in clinic. Pharmacologic potency of newly synthesized K-opener is being evaluated with efflux capacity of preincubated Rb-83 from the isolated aortic vascular tissue preparation. Thallium has similar characteristics to those of rubidium and potassium in vivo. To evaluate the effect of pinacidil (a potent K-opener) on Tl-201 biokinetics, we have performed uptake/washout studies in cultured myocytes, and mice biodistribution study. Primary culture of spontaneous contracting myocytes was undertake from hearts of newborn Sprague-Dawley rat. Different concentration of pinacidil (100nM or 10uM) was co-incubated with Tl-201 in HBSS buffer to evaluate its effect on cellular uptake, or challenged to myocyte preparations pre-incubated with Tl-201 for washout study. Pinacidil was injected into mice simultaneous or 10-min after Tl-201 injection, and organ uptake and whole body retention ratio was measured using gamma counter or dose calibrator. Co-incubation of pinacidil with Tl-201 resulted in a decrease in Tl uptake into myocytes by 1.6 - 2.5 times, and an increase in washout by 1.6 - 3.1 times. Pinacidil injection resulted in mild decrease in blood, heart and liver uptake in mice, bur renal uptake was markedly decreased in a dose dependent manner. These results suggest that the pinacidil Tl-201 kinetics and may potentially affect the interpretation of Tl-201 myocardial imaging.

  20. Disappearance of myocardial perfusion defects on prone SPECT imaging: Comparison with cardiac magnetic resonance imaging in patients without established coronary artery disease

    Directory of Open Access Journals (Sweden)

    Hedén Bo

    2009-08-01

    Full Text Available Abstract Background It is of great clinical importance to exclude myocardial infarction in patients with suspected coronary artery disease who do not have stress-induced ischemia. The diagnostic use of myocardial perfusion single-photon emission computed tomography (SPECT in this situation is sometimes complicated by attenuation artifacts that mimic myocardial infarction. Imaging in the prone position has been suggested as a method to overcome this problem. Methods In this study, 52 patients without known prior infarction and no stress-induced ischemia on SPECT imaging were examined in both supine and prone position. The results were compared with cardiac magnetic resonance imaging (CMR with delayed-enhancement technique to confirm or exclude myocardial infarction. Results There were 63 defects in supine-position images, 37 of which disappeared in the prone position. None of the 37 defects were associated with myocardial infarction by CMR, indicating that all of them represented attenuation artifacts. Of the remaining 26 defects that did not disappear on prone imaging, myocardial infarction was confirmed by CMR in 2; the remaining 24 had no sign of ischemic infarction but 2 had other kinds of myocardial injuries. In 3 patients, SPECT failed to detect small scars identified by CMR. Conclusion Perfusion defects in the supine position that disappeared in the prone position were caused by attenuation, not myocardial infarction. Hence, imaging in the prone position can help to rule out ischemic heart disease for some patients admitted for SPECT with suspected but not documented ischemic heart disease. This would indicate a better prognosis and prevent unnecessary further investigations and treatment.

  1. Adenosine-stress dynamic myocardial perfusion imaging with second-generation dual-source CT: comparison with conventional catheter coronary angiography and SPECT nuclear myocardial perfusion imaging.

    Science.gov (United States)

    Wang, Yining; Qin, Ling; Shi, Ximin; Zeng, Yong; Jing, Hongli; Schoepf, U Joseph; Jin, Zhengyu

    2012-03-01

    The purpose of this article is to evaluate the feasibility of adenosine-stress dynamic myocardial perfusion imaging (MPI) with 128-MDCT dual-source CT for detecting myocardial ischemia in comparison with conventional catheter coronary angiography and nuclear MPI. Thirty patients (21 men and nine women; mean [± SD] age, 59.2 ± 7.6 years) prospectively underwent a combined stress CT perfusion and CT angiography (CTA) examination. Complete time-attenuation curves of the myocardium were acquired with prospectively ECG-triggered axial images at two alternating positions. Myocardial blood flow (MBF) was quantified according to dynamic CT perfusion, and MBF values of normal and abnormal segments were compared. Findings on CT perfusion were compared with those for stress and rest SPECT. Perfusion defects according to CT were correlated to flow-obstructing stenosis detected on CTA and catheter coronary angiography. On stress CT perfusion, 19 patients (63%) and 83 of 504 segments (16%) had perfusion abnormalities. There was a significant difference in MBF values between normal (142.9 ± 30.6 mL/100 mL/min) and hypoperfused (90.0 ± 22.8 mL/100 mL/min) segments (p stress CT perfusion detects myocardial perfusion defects in good correlation with nuclear MPI. CT perfusion combined with CTA improves the diagnostic accuracy for identifying flow-obstructing stenosis compared with CTA alone.

  2. Optimization and comparison of simultaneous and separate acquisition protocols for dual isotope myocardial perfusion SPECT

    Science.gov (United States)

    Ghaly, Michael; Links, Jonathan M.; Frey, Eric C.

    2015-07-01

    Dual-isotope simultaneous-acquisition (DISA) rest-stress myocardial perfusion SPECT (MPS) protocols offer a number of advantages over separate acquisition. However, crosstalk contamination due to scatter in the patient and interactions in the collimator degrade image quality. Compensation can reduce the effects of crosstalk, but does not entirely eliminate image degradations. Optimizing acquisition parameters could further reduce the impact of crosstalk. In this paper we investigate the optimization of the rest Tl-201 energy window width and relative injected activities using the ideal observer (IO), a realistic digital phantom population and Monte Carlo (MC) simulated Tc-99m and Tl-201 projections as a means to improve image quality. We compared performance on a perfusion defect detection task for Tl-201 acquisition energy window widths varying from 4 to 40 keV centered at 72 keV for a camera with a 9% energy resolution. We also investigated 7 different relative injected activities, defined as the ratio of Tc-99m and Tl-201 activities, while keeping the total effective dose constant at 13.5 mSv. For each energy window and relative injected activity, we computed the IO test statistics using a Markov chain Monte Carlo (MCMC) method for an ensemble of 1,620 triplets of fixed and reversible defect-present, and defect-absent noisy images modeling realistic background variations. The volume under the 3-class receiver operating characteristic (ROC) surface (VUS) was estimated and served as the figure of merit. For simultaneous acquisition, the IO suggested that relative Tc-to-Tl injected activity ratios of 2.6-5 and acquisition energy window widths of 16-22% were optimal. For separate acquisition, we observed a broad range of optimal relative injected activities from 2.6 to 12.1 and acquisition energy window of widths 16-22%. A negative correlation between Tl-201 injected activity and the width of the Tl-201 energy window was observed in these ranges. The results

  3. Absolute quantitation of myocardial blood flow with {sup 201}Tl and dynamic SPECT in canine: optimisation and validation of kinetic modelling

    Energy Technology Data Exchange (ETDEWEB)

    Iida, Hidehiro; Kim, Kyeong-Min; Nakazawa, Mayumi; Sohlberg, Antti; Zeniya, Tsutomu; Hayashi, Takuya; Watabe, Hiroshi [National Cardiovascular Center Research Institute, Department of Investigative Radiology, Suita City, Osaka (Japan); Eberl, Stefan [National Cardiovascular Center Research Institute, Department of Investigative Radiology, Suita City, Osaka (Japan); Royal Prince Alfred Hospital, PET and Nuclear Medicine Department, Camperdown, NSW (Australia); Tamura, Yoshikazu [Akita Kumiai General Hospital, Department of Cardiology, Akita City (Japan); Ono, Yukihiko [Akita Research Institute of Brain, Akita City (Japan)

    2008-05-15

    {sup 201}Tl has been extensively used for myocardial perfusion and viability assessment. Unlike {sup 99m}Tc-labelled agents, such as {sup 99m}Tc-sestamibi and {sup 99m}Tc-tetrofosmine, the regional concentration of {sup 201}Tl varies with time. This study is intended to validate a kinetic modelling approach for in vivo quantitative estimation of regional myocardial blood flow (MBF) and volume of distribution of {sup 201}Tl using dynamic SPECT. Dynamic SPECT was carried out on 20 normal canines after the intravenous administration of {sup 201}Tl using a commercial SPECT system. Seven animals were studied at rest, nine during adenosine infusion, and four after beta-blocker administration. Quantitative images were reconstructed with a previously validated technique, employing OS-EM with attenuation-correction, and transmission-dependent convolution subtraction scatter correction. Measured regional time-activity curves in myocardial segments were fitted to two- and three-compartment models. Regional MBF was defined as the influx rate constant (K{sub 1}) with corrections for the partial volume effect, haematocrit and limited first-pass extraction fraction, and was compared with that determined from radio-labelled microspheres experiments. Regional time-activity curves responded well to pharmacological stress. Quantitative MBF values were higher with adenosine and decreased after beta-blocker compared to a resting condition. MBFs obtained with SPECT (MBF{sub SPECT}) correlated well with the MBF values obtained by the radio-labelled microspheres (MBF{sub MS}) (MBF{sub SPECT} = -0.067 + 1.042 x MBF{sub MS}, p < 0.001). The three-compartment model provided better fit than the two-compartment model, but the difference in MBF values between the two methods was small and could be accounted for with a simple linear regression. Absolute quantitation of regional MBF, for a wide physiological flow range, appears to be feasible using {sup 201}Tl and dynamic SPECT. (orig.)

  4. Factors affecting the myocardial activity acquired during exercise SPECT with a high-sensitivity cardiac CZT camera as compared with conventional Anger camera.

    Science.gov (United States)

    Verger, Antoine; Imbert, Laetitia; Yagdigul, Yalcine; Fay, Renaud; Djaballah, Wassila; Rouzet, François; Fourquet, Nicolas; Poussier, Sylvain; Roch, Véronique; Le Guludec, Dominique; Karcher, Gilles; Marie, Pierre-Yves

    2014-03-01

    Injected doses are difficult to optimize for exercise SPECT since they depend on the myocardial fraction of injected activity (MFI) that is detected by the camera. The aim of this study was to analyse the factors affecting MFI determined using a cardiac CZT camera as compared with those determined using conventional Anger cameras. Factors affecting MFI were determined and compared in patients who had consecutive exercise SPECT acquisitions with (201)Tl (84 patients) or (99m)Tc-sestamibi (87 patients) with an Anger or a CZT camera. A predictive model was validated in a group of patients routinely referred for (201)Tl (78 patients) or (99m)Tc-sestamibi (80 patients) exercise CZT SPECT. The predictive model involved: (1) camera type, adjusted mean MFI being ninefold higher for CZT than for Anger SPECT, (2) tracer type, adjusted mean MFI being twofold higher for (201)Tl than for (99m)Tc-sestamibi, and (3) logarithm of body weight. The CZT SPECT model led to a +1 ± 26% error in the prediction of the actual MFI from the validation group. The mean MFI values estimated for CZT SPECT were more than twofold higher in patients with a body weight of 60 kg than in patients with a body weight of 120 kg (15.9 and 6.8 ppm for (99m)Tc-sestamibi and 30.5 and 13.1ppm for (201)Tl, respectively), and for a 14-min acquisition of up to one million myocardial counts, the corresponding injected activities were only 80 and 186 MBq for (99m)Tc-sestamibi and 39 and 91 MBq for (201)Tl, respectively. Myocardial activities acquired during exercise CZT SPECT are strongly influenced by body weight and tracer type, and are dramatically higher than those obtained using an Anger camera, allowing very low-dose protocols to be planned, especially for (99m)Tc-sestamibi and in non-obese subjects.

  5. The Association between Left Verticle Diastolic Dysfunction and Endothelial Dysfunction and the Result of Stress Myocardial SPECT in Asymptomatic Patients with Type 2 Diabetes

    Czech Academy of Sciences Publication Activity Database

    Charvát, J.; Michalová, K.; Chlumský, J.; Valenta, Zdeněk; Kvapil, M.

    2005-01-01

    Roč. 33, - (2005), s. 473-482 ISSN 0300-0605 Institutional research plan: CEZ:AV0Z10300504 Keywords : coronary heart disease * type 2 diabetes mellitus * left ventricular diastolic dysfunction * left ventricular hyperthropy * stress myocardial SPECT Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery Impact factor: 0.653, year: 2005

  6. Relative value of thallium-201 and iodine-131 scans in the detection of recurrence or distant metastasis of well differentiated thyroid carcinoma.

    Science.gov (United States)

    Lin, J D; Kao, P F; Weng, H F; Lu, W T; Huang, M J

    1998-07-01

    Radioactive iodine (131I) has been found to be more sensitive and more specific than thallium-201 for the detection of distant metastases and thyroid remnants in the neck in cases of well-differentiated thyroid carcinoma. 201Tl has been deemed particularly useful in localizing metastases or recurrence in patients with a negative 131I scan and abnormal levels of serum thyroglobulin (Tg). This study aimed to: (1) determine the value of 201Tl imaging in localizing metastases or recurrence in patients with well-differentiated thyroid carcinoma, and (2) evaluate the false-positive and false-negative results of 131I and 201Tl scintigraphy. Sixty-two thyroid remnant ablated patients who underwent simultaneous postoperative 201Tl and 131I scans and and serum Tg determinations were evaluated. Fifty patients had papillary thyroid carcinomas and 12 had follicular thyroid carcinomas. 201Tl imaging was performed before the 131I studies. Of the 62 patients who underwent 201Tl imaging studies, 24 were found to have positive results, with local recurrence or distant metastases. Patients with positive results in the 201Tl imaging studies tended to be older, were mor often male, had higher Tg levels and had a higher recurrence rate. Of these 24 patients, ten had negative diagnostic or therapeutic 131I scans. Concurrently, serum Tg levels were less than 5 ng/ml in five of these ten patients. Three patients were deemed false positive by 201Tl scans; one had a parotid tumour, one a periodontal abscess and one lung metastasis. Among the 38 patients with negative 201Tl scans, 11 had positive findings on 131I scans. Three had distant metastases: two with lung metastases and one with bone metastases. Patients with false-positive results on 131I scans included those with biliary tract stones, ovarian cysts, and breast secretion. Of the 27 patients with negative 201Tl and 131I scans, 15 had elevated serum Tg levels. Among these, local recurrence followed by lung metastases was manifested in

  7. Relative value of thallium-201 and iodine-131 scans in the detection of recurrence or distant metastasis of well differentiated thyroid carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Lin Jen-Der; Weng Hsiao-Fen; Lu Wen-Tsoung [Division of Endocrinology and Metabolism, Chang Gung Memorial Hospital (Taiwan, Province of China); Kao Pan-Fu; Huang Miau-Ju [Department of Nuclear Medicine, Chang Gung Memorial Hospital, Taiwan (Taiwan, Province of China)

    1998-07-01

    Radioactive iodine ({sup 131}I) has been found to be more sensitive and more specific than thallium-201 for the detection of distant metastases and thyroid remnants in the neck in cases of well-differentiated thyroid carcinoma. {sup 201}Tl has been deemed particularly useful in localizing metastases or recurrence in patients with a negative {sup 131}I scan and abnormal levels of serum thyroglobulin (Tg). This study aimed to: (1) determine the value of {sup 201}Tl imaging in localizing metastases or recurrence in patients with well-differentiated thyroid carcinoma, and (2) evaluate the false-positive and false-negative results of {sup 131}I and {sup 201}Tl scintigraphy. Sixty-two thyroid remnant ablated patients who underwent simultaneous postoperative {sup 201}Tl and {sup 131}I scans and and serum Tg determinations were evaluated. Fifty patients had papillary thyroid carcinomas and 12 had follicular thyroid carcinomas. {sup 201}Tl imaging was performed before the {sup 131}I studies. Of the 62 patients who underwent {sup 201}Tl imaging studies, 24 were found to have positive results, with local recurrence or distant metastases. Patients with positive results in the {sup 201}Tl imaging studies tended to be older, were mor often male, had higher Tg levels and had a higher recurrence rate. Of these 24 patients, ten had negative diagnostic or therapeutic {sup 131}I scans. Concurrently, serum Tg levels were less than 5 ng/ml in five of these ten patients. Three patients were deemed false positive by {sup 201}Tl scans; one had a parotid tumour, one a periodontal abscess and one lung metastasis. Among the 38 patients with negative {sup 201}Tl scans, 11 had positive findings on {sup 131}I scans. Three had distant metastases: two with lung metastases and one with bone metastases. Patients with false-positive results on {sup 131}I scans included those with biliary tract stones, ovarian cysts, and breast secretion. Of the 27 patients with negative {sup 201}Tl and {sup 131}I

  8. Relation between myocardial damage and disease activity in patients with systemic lupus erythematosus by exercise {sup 201}Tl scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Kuzumoto, Masayuki [Nara Medical Univ. (Japan)

    1997-08-01

    Myocardial damage in patients with systemic lupus erythematosus (SLE) was evaluated using exercise thallium-201 myocardial scintigraphy, and the relationship between myocardial damage and disease activity of SLE was examined. Twenty-seven patients (26 women and 1 man, mean age 43 years), in whom extramural coronary artery lesions were excluded by coronary angiogram or presumed to be excluded by exercise electrocardiogram, were enrolled in this study. The mean duration of disease and the mean duration of corticosteroid therapy in these patients were 94 and 77 months, respectively. Exercise thallium-201 scintigraphy was performed twice (mean interval, 30 months) to evaluate the progression of myocardial damage. Myocardial ischemia as an index of myocardial damage was evaluated by visual analysis and ischemic score (IS). The changes in myocardial ischemia were categorized into 3 groups: improved, unchanged or worsened. The disease activity of SLE was determined by the SLE Disease Activity Index (SLEDAI), and the changes in this index were classified into the same three categories, as evaluated every six months between the two scintigraphic examinations. Disease activity was significantly correlated with myocardial ischemia (p<0.05), and with myocardial ischemia as diagnosed by {Delta}IS (difference in ischemic score between the first and second thallium-201 scintigrams: p<0.005). But neither the duration of disease nor the duration of corticosteroid therapy was correlated with IS at the first scintigraphy. These results indicate that control of SLE disease activity may be critical in the treatment of myocardial damage resulting from vascular lesions, especially intramyocardial small-artery disease, in patients with SLE. (author)

  9. Reversal of rest myocardial asynergy during exercise: a radionuclide scintigraphic study

    Energy Technology Data Exchange (ETDEWEB)

    Kimchi, A.; Rozanski, A.; Fletcher, C.; Maddahi, J.; Swan, H.J.; Berman, D.S.

    1985-11-01

    While exercise-induced segmental left ventricular wall motion abnormalities are well described, the phenomenon of improvement in certain asynergic segments during exercise in some patients remains a curiosity. To assess this unexpected finding, results were analyzed in 85 patients with wall motion abnormalities at rest who underwent two view exercise radionuclide ventriculography and exercise thallium-201 myocardial perfusion imaging. Wall motion was scored with a 5 point system; normalization or increase of 2 or more points with exercise signified improvement. Forty-eight patients (56%) had no change or further deterioration of wall motion at peak exercise, 15 (18%) showed both improvement of wall motion and deterioration and 22 (26%) showed only improvement of wall motion. Wall motion improvement during exercise was found in 57 (20%) of 279 segments with asynergy at rest. Of these 57 segments improving with exercise, 45 (79%) showed mild and 12 (21%) showed severe asynergy at rest. Only seven segments (12%) were associated with pathologic Q waves. Thallium-201 perfusion was normal in 44 segments (77%) while only 6 segments (11%) had reversible and only 7 (12%) had nonreversible thallium-201 defects. In conclusion segments with abnormal wall motion at rest that show improvement with exercise appear to represent viable nonischemic segments.

  10. Prognostic value of normal exercise {sup 99m}Tc-MIBI myocardial perfusion SPECT: comparison with exercise electrocardiography and coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang Woo; Lee, Jae Tae; Chun, Kyung Ah; Kang, Do Young; Kim, Dong Hwan; Cho, Yong Keun; Chae, Shung Chull; Lee, Kyu Bo [Kyungpook National Univ. College of Medicine, Taegu (Korea, Republic of)

    2000-06-01

    Myocardial perfusion scintigraphy is a useful technique to diagnose and to predict prognosis in patients with suspected or known coronary artery disease. The purpose of the present study is to evaluate the prognostic value of normal exercise {sup 99m}Tc-MIBI myocardial perfusion single photon emission computed tomography (SPECT) and to analyze results with regard to those of exercise electrocardiography or coronary angiography. We evaluated 301 patients (mean age 52{+-}10 years, 166 males and 135 females) with normal exercise {sup 99m}Tc-MIBI myocardial perfusion SPECT performed for suspected coronary artery disease. Subjects were evaluated for cardiac events and followed for 8-55 months (mean 19{+-}10 months) after imaging. During the follow-up period, there was no cardiac death but only one non-fatal myocardial infarction (event rate 0.21% per year). In addition, only one patient underwent coronary revascularization. There was no significant difference in cardiac event rate between patinets with positive (n=3D27) and negative (n=3D235) exercise electrocardiography (p:NS). There was no cardiac event in 17 patients who underwent coronary angiography (4 patients with >50% luminal narrowing, 2 patients with vasospasm and 11 patients with no significant lesion). Patients with normal exercise {sup 99m}Tc-MIBI myocardial perfusion SPECT has a very low risk for cardiac events regardless of exercise electrocardiographic and coronary angiographic findings.

  11. Myocardial CT perfusion imaging and SPECT for the diagnosis of coronary artery disease

    DEFF Research Database (Denmark)

    George, Richard T; Mehra, Vishal C; Chen, Marcus Y

    2014-01-01

    . MATERIALS AND METHODS: This study was approved by the institutional review board. Written informed consent was obtained from all patients. Sixteen centers enrolled 381 patients from November 2009 to July 2011. Patients underwent rest and adenosine stress CT perfusion imaging and rest and either exercise...... or pharmacologic stress SPECT before and within 60 days of coronary angiography. Images from CT perfusion imaging, SPECT, and coronary angiography were interpreted at blinded, independent core laboratories. The primary diagnostic parameter was the area under the receiver operating characteristic curve (Az...

  12. Effect of verapamil on myocardial ischemia in patients with hypertrophic cardiomyopathy; Evaluation by exercise [sup 201]Tl SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Taniguchi, Yoko; Sugihara, Hiroki; Ootsuki, Katsuichi (Kyoto Prefectural Univ. of Medicine (Japan)) (and others)

    1993-01-01

    Effect of verapamil on myocardial ischemia in patients with hypertrophic cardiomyopathy (HCM) was evaluated by exercise stress myocardial [sup 201]Tl SPECT (EX-Tl). EX-Tl was performed before and after 8.8 weeks of oral verapamil (240 mg/day) in 12 patients with HCM who showed transient [sup 201]Tl perfusion defects under control conditions. [sup 201]Tl perfusion defect was visually scored and judged for 4 grades as normal (0), mild defect (1), moderate defect (2), and severe defect (3). Transient dilation index (TDI) was calculated as an index of subendocardial ischemia. Improvements of defect score were demonstrated in 10 patients after administration of verapamil. Two patients showed no change of defect score. Mean defect score decreased significantly from 5.50 to 3.03 (p<0.001). Although 11 of 12 patients showed abnormal TDI under control conditions, 10 of these revealed improvements of TDI and 7 of the 10 disclosed normal TDI after verapamil. Mean TDI decreased from 1.263 to 1.090 significantly (p<0.01). In conclusion, verapamil may improve myocardial ischemia in patients with HCM. (author).

  13. First-arterial-pass dual-energy CT for assessment of myocardial blood supply: do we need rest, stress, and delayed acquisition? Comparison with SPECT.

    Science.gov (United States)

    Meinel, Felix G; De Cecco, Carlo N; Schoepf, U Joseph; Nance, John W; Silverman, Justin R; Flowers, Brian A; Henzler, Thomas

    2014-03-01

    To compare the relative contributions of rest, stress, and delayed acquisitions with the accuracy of dual-energy (DE) computed tomography (CT) for the assessment of myocardial blood supply. With institutional review board approval and HIPAA compliance, 55 consecutive patients (10 women, 45 men; mean age, 62 years ± 10) clinically referred for cardiac single photon emission computed tomography (SPECT) who were known to have or were suspected of having coronary artery disease were prospectively enrolled. DE CT studies were acquired during adenosine stress, at rest, and after 6-minute delay. The DE CT iodine distribution maps were visually assessed for perfusion deficits or late iodine enhancement. Per-segment agreement between modalities was investigated with κ statistics. Test characteristics for the detection of perfusion deficits were calculated for combinations of rest, stress, and delayed DE CT acquisition, with SPECT as reference standard. At SPECT, 714 segments were considered normal, 192 showed fixed perfusion defects, and 29 showed reversible perfusion deficits. Sensitivity of rest-only DE CT was 92%, and specificity was 98%. Stress-only, rest-stress, stress and delayed, and the combination of all three had a sensitivity of 99% and a specificity of 97%. Of 29 segments with reversible perfusion deficits at SPECT, 13 (45%) were misclassified by using rest-stress DE CT as fixed perfusion deficits. With stress DE CT plus delayed acquisition, 13 of 192 (7%) segments with fixed perfusion deficits at SPECT were misclassified as reversible. Rest-stress acquisition should be the protocol of choice for assessment of the myocardial blood supply in DE CT. The accuracy of DE CT is not increased by the addition of a delayed DE CT acquisition, which may therefore be omitted to reduce radiation exposure. With rest-stress DE CT, almost one-half of defects that are reversible at SPECT were classified as fixed; radiologists and clinicians need to be aware of this

  14. LV dyssynchrony as assessed by phase analysis of gated SPECT myocardial perfusion imaging in patients with Wolff-Parkinson-White syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Chun; Li, Dianfu; Miao, Changqing; Zhou, Yanli; Cao, Kejiang [First Affiliated Hospital of Nanjing Medical University, Department of Cardiology, Nanjing, Jiangsu (China); Feng, Jianlin [First Affiliated Hospital of Nanjing Medical University, Department of Nuclear Medicine, Nanjing, Jiangsu (China); Lloyd, Michael S. [Emory University School of Medicine, Division of Cardiology, Atlanta, GA (United States); Chen, Ji [Emory University School of Medicine, Department of Radiology and Imaging Sciences, Atlanta, GA (United States)

    2012-07-15

    The purpose of this study was to evaluate left ventricular (LV) mechanical dyssynchrony in patients with Wolff-Parkinson-White (WPW) syndrome pre- and post-radiofrequency catheter ablation (RFA) using phase analysis of gated single photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI). Forty-five WPW patients were enrolled and had gated SPECT MPI pre- and 2-3 days post-RFA. Electrophysiological study (EPS) was used to locate accessory pathways (APs) and categorize the patients according to the AP locations (septal, left and right free wall). Electrocardiography (ECG) was performed pre- and post-RFA to confirm successful elimination of the APs. Phase analysis of gated SPECT MPI was used to assess LV dyssynchrony pre- and post-RFA. Among the 45 patients, 3 had gating errors, and thus 42 had SPECT phase analysis. Twenty-two patients (52.4 %) had baseline LV dyssynchrony. Baseline LV dyssynchrony was more prominent in the patients with septal APs than in the patients with left or right APs (p < 0.05). RFA improved LV synchrony in the entire cohort and in the patients with septal APs (p < 0.01). Phase analysis of gated SPECT MPI demonstrated that LV mechanical dyssynchrony can be present in patients with WPW syndrome. Septal APs result in the greatest degree of LV mechanical dyssynchrony and afford the most benefit after RFA. This study supports further investigation in the relationship between electrical and mechanical activation using EPS and phase analysis of gated SPECT MPI. (orig.)

  15. Evaluation of the therapeutic effect of hyperbaric oxygenation and erythropoietin in the treatment of chronic heart failure using myocardial perfusion scintigraphy G-SPECT

    Directory of Open Access Journals (Sweden)

    Baškot Branislav

    2009-01-01

    Full Text Available Background. The most important predictors of longterm survival in patients with cardiac ischemic disease are left ventricular ejection fraction, left ventricular volumes, infarction size, presence and extent of residual myocardial ischemia. One of the most important recent developments in single photon emission computed tomography (SPECT myocardial perfusion imaging is the ability to acquire these studies in conjunction with electrocardiogram (ECG gating (G-SPECT. The ability to asses radionuclide myocardial perfusion and function with ECG G-SPECT imaging has revolutionized this field of nuclear cardiology. Study with G-SPECT development algorithms permits to quantify measures of left ventricular (LV volume, ejection fraction (LVEF and even regional myocardial wall motion and thickening. The American Society of Nuclear Cardiology (ASNC in its position paper from March 1999 recommends the routine incorporation of G-SPECT during cardiac perfusion scintigraphy. Case report. We presented a 70-year-old male with ischemic heart disease (dilatative, cardiomyopathy and absolute arrhythmia. He was few times hospitally treated by medicamentous therapy with no evidence of improvement. After hospital treatment, we included hyperbaric oxygenation (HBO and erythropoietin injections. Hyperbaric oxygenation was carried out in a monoplace hyperbaric chamber, BLK S-303, by a graduated protocol for patients with severe heart insufficiency, totally 15 treatments. Recombinant erythropoietin beta (RecormonR F. Hoffmann-La Roche was applied deeply subcutaneously, every second day from 2 000 IU to totally 16 000 IU. Before the therapy G-SPECT study was performed with 99m technetium-MIBI, and we obtained the functional parameters and perfusion of the left ventricle to follow-up the therapy effects. The study was performed by an ADAC-VERTEX PLUS-EPIC two-head gamma camera with dedicated quantitatively algorithm Auto-QUANT. The results of LVEF were 15%, with severity

  16. Automatic Valve Plane Localization in Myocardial Perfusion SPECT/CT by Machine Learning: Anatomic and Clinical Validation.

    Science.gov (United States)

    Betancur, Julian; Rubeaux, Mathieu; Fuchs, Tobias A; Otaki, Yuka; Arnson, Yoav; Slipczuk, Leandro; Benz, Dominik C; Germano, Guido; Dey, Damini; Lin, Chih-Jen; Berman, Daniel S; Kaufmann, Philipp A; Slomka, Piotr J

    2017-06-01

    Precise definition of the mitral valve plane (VP) during segmentation of the left ventricle for SPECT myocardial perfusion imaging (MPI) quantification often requires manual adjustment, which affects the quantification of perfusion. We developed a machine learning approach using support vector machines (SVM) for automatic VP placement. Methods: A total of 392 consecutive patients undergoing 99mTc-tetrofosmin stress (5 min; mean ± SD, 350 ± 54 MBq) and rest (5 min; 1,024 ± 153 MBq) fast SPECT MPI attenuation corrected (AC) by CT and same-day coronary CT angiography were studied; included in the 392 patients were 48 patients who underwent invasive coronary angiography and had no known coronary artery disease. The left ventricle was segmented with standard clinical software (quantitative perfusion SPECT) by 2 experts, adjusting the VP if needed. Two-class SVM models were computed from the expert placements with 10-fold cross validation to separate the patients used for training and those used for validation. SVM probability estimates were used to compute the best VP position. Automatic VP localizations on AC and non-AC images were compared with expert placement on coronary CT angiography. Stress and rest total perfusion deficits and detection of per-vessel obstructive stenosis by invasive coronary angiography were also compared. Results: Bland-Altman 95% confidence intervals (CIs) for VP localization by SVM and experts for AC stress images (bias, 1; 95% CI, -5 to 7 mm) and AC rest images (bias, 1; 95% CI, -7 to 10 mm) were narrower than interexpert 95% CIs for AC stress images (bias, 0; 95% CI, -8 to 8 mm) and AC rest images (bias, 0; 95% CI, -10 to 10 mm) (P characteristic curve for the 2 experts (AUC, 0.79 [95% CI, 0.7-0.87]; AUC, 0.81 [95% CI, 0.73-0.89]) and the SVM (0.82 [0.74-0.9]) for AC data were the same (P = NS) and were higher than those for the unadjusted VP (0.63 [0.53-0.73]) (P characteristic curve for the experts (AUC, 0.77 [95% CI, 0.69-0.89]; AUC

  17. Very low-activity stress/high-activity rest, single-day myocardial perfusion SPECT with a conventional sodium iodide camera and wide beam reconstruction processing.

    Science.gov (United States)

    DePuey, E Gordon; Ata, Pashmina; Wray, Rick; Friedman, Marvin

    2012-10-01

    A stress (S)/rest (R) 1-day Tc-99m sestamibi protocol is logistically advantageous and facilitates stress-only imaging. However, with conventional 370 MBq (10 mCi) S activity and subsequent 1,110-1,295 MBq (30-35 mCi) R activity there is a risk of S-to-R "shine-through" and underestimation of defect reversibility. New software methods cope with lower counting statistics and should allow for both a reduced S activity and also less likelihood of S-to-R "shine-through." 102 prospective patients [49 men, 53 women; mean weight 178 ± 41 lbs (range 98-265 lbs); chest 41.5″ ± 4.0″ (range 32″-52″)] received 192.4 + 18.5 MBq (5.2 ± 0.5 mCi) Tc-99m sestamibi S (25 exercise, 77 regadenoson) activity followed in 30-40 minutes by "full-time" (12 minutes) two-headed NaI camera S SPECT. Immediately thereafter, a 16-minute S SPECT acquisition was also performed in 37/102 patients. Then at 60-80 minute post-S all patients received 1328.3 + 129.5 MBq (35.9 ± 3.5 mCi) Tc-99m sestamibi, and "half-time" (7.5 minutes) R SPECT was acquired. All tomograms were processed with wide beam reconstruction (WBR, UltraSPECT Ltd.) software. A time-adjusted R/S myocardial count density ratio (MCDR) was calculated using automated software. S SPECT quality was visually graded (poor, fair, good, excellent) based upon myocardial definition, cavity contrast, RV visualization, and noise. For comparison, the S/R MCDR was calculated in 581 consecutive patients undergoing a conventional 370 MBq R/1110 MBq S (10 mCi R/30 mCi S) protocol. S SPECT was normal in 44 patients (43%). Image quality was good-excellent in 93 (91%) patients with 12-minute S SPECT. Also in 37 (98%) patients with 16-minute S SPECT, quality was good-excellent. In patients with >42″ chests 12-minute S SPECT quality worsened with increasing chest circumference, manifested by myocardial "blurring." Image quality improved by ≥1 grade in the 12/37 patients (32%) also undergoing 16-minute S SPECT. The time- and decay

  18. Aid in the detection of myocardial perfusion abnormality utilizing SPECT atlas and images registration: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Padua, Rodrigo Donizete Santana de [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Div. de Cardiologia]. E-mail: rodrigo_dsp@hcrp.fmrp.usp.br; Oliveira, Lucas Ferrari de [Universidade Federal de Pelotas (UFPel), RS (Brazil). Inst. de Fisica e Matematica. Dept. de Tecnologia da Informacao; Marques, Paulo Mazzoncini de Azevedo [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Centro de Ciencias das Imagens e Fisica Medica; Groote, Jean-Jacques Georges Soares de [Instituto de Ensino Superior COC, Ribeirao Preto, SP (Brazil). Lab. of Artifical Intelligence and Applications; Castro, Adelson Antonio de [Universidade de Sao Paulo (USP), Ribeirao Preto, SP, (Brazil). Faculdade de Medicina; Ana, Lauro Wichert [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Centro de Ciencias das Imagens e Fisica Medica; Simoes, Marcus Vinicius [Universidade de Sao Paulo (USP), Ribeirao Preto, SP, (Brazil). Faculdade de Medicina. Divisao de Cardiologia

    2008-11-15

    To develop an atlas of myocardial perfusion scintigraphy and evaluating its applicability in computer-aided detection of myocardial perfusion defects in patients with ischemic heart disease. The atlas was created with rest-stress myocardial perfusion scintigraphic images of 20 patients of both genders with low probability of coronary artery disease and considered as normal by two experienced observers. Techniques of image registration and mathematical operations on images were utilized for obtaining template images depicting mean myocardial uptake and standard deviation for each gender and physiological condition. Myocardial perfusion scintigraphy images of one male and one female patient were aligned with the corresponding atlas template image, and voxels with myocardial uptake rates two standard deviations below the mean voxel value of the respective region in the atlas template image were highlighted on the tomographic sections and confirmed as perfusion defects by both observe. The present study demonstrated the creation of an atlas of myocardial perfusion scintigraphy with promising results of this tool as an aid in the detection of myocardial perfusion defects. However, further prospective validation with a more representative sample is recommended. (author)

  19. Effect of a patient-specific minimum activity in stress myocardial perfusion imaging using CZT-SPECT: Prognostic value, radiation dose, and scan outcome.

    Science.gov (United States)

    van Dijk, J D; Borren, N M; Mouden, M; van Dalen, J A; Ottervanger, J P; Jager, P L

    2017-08-18

    SPECT Myocardial perfusion imaging (MPI) is associated with a relatively high radiation burden and decreasing image quality in heavy patients. Patient-specific low-activity protocols (PLAPs) are suggested but follow-up data is lacking. Our aim was to compare the use of a standard fixed-activity protocol (FAP) with a PLAP in cadmium zinc telluride (CZT)-SPECT MPI. We retrospectively included 1255 consecutive patients who underwent CZT-SPECT stress-optional rest MPI. 668 Patients were scanned using FAP (370 MBq) and 587 patients using PLAP (2.25 MBq·kg(-1)). Percentage of scans interpreted as normal, radiation dose, and 1-year follow-up including hard event rates (all-cause death or non-fatal myocardial infarction) were collected and compared. The percentage of scans interpreted as normal was 67% in FAP and 70% in PLAP groups (P = .29). The annualized hard event rates in these patients were 1.0% in the FAP and 0.9% in the PLAP group (P = .86). However, the mean radiation dose decreased by 23% for stress-only and by 15% to 2.6 mSv for stress-optional rest MPI after introduction of the PLAP (p<0.001). Introduction of a patient-specific low-activity protocol does not affect the percentage of scans interpreted as normal or prognosis but significantly lowers the radiation dose for CZT-SPECT MPI.

  20. Influence of proton-pump inhibitors on stomach wall uptake of 99mTc-tetrofosmin in cadmium-zinc-telluride SPECT myocardial perfusion imaging.

    Science.gov (United States)

    Mouden, Mohamed; Rijkee, Karlijn S; Schreuder, Nanno; Timmer, Jorik R; Jager, Pieter L

    2015-02-01

    Proton-pump inhibitors (PPIs) induce potentially interfering stomach wall activity in single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI) with technetium-99m ((99m)Tc)-sestamibi. However, no data are available for (99m)Tc-tetrofosmin. We assessed the influence of prolonged (>2 weeks) PPI use on the stomach wall uptake of (99m)Tc-tetrofosmin in patients referred for stress MPI with a cadmium-zinc-telluride-based SPECT camera and its relation with dyspepsia symptoms. Consecutive patients (n=127) underwent a 1-day adenosine stress-first SPECT-MPI with (99m)Tc-tetrofosmin, of whom 54 (43%) patients had been on PPIs for more than 2 weeks. Stomach wall activity was identified on stress SPECT using computed tomographic attenuation maps and was scored using a four-point grading scale into clinically relevant (scores 2 or 3) or nonrelevant (scores 0 or 1).Patients on PPIs had stomach wall uptake more frequently as compared with patients not using PPIs (22 vs. 7%, P=0.017). Dyspepsia was similar in both groups. Prolonged use of PPIs is associated with stomach wall uptake of (99m)Tc-tetrofosmin in stress cadmium-zinc-telluride-SPECT images. Gastric symptoms were not associated with stomach wall uptake.

  1. Myocardial blood flow measurement with a conventional dual-head SPECT/CT with spatiotemporal iterative reconstructions - a clinical feasibility study.

    Science.gov (United States)

    Alhassen, Fares; Nguyen, Nhan; Bains, Sukhkarn; Gould, Robert G; Seo, Youngho; Bacharach, Stephen L; Song, Xiyun; Shao, Lingxiong; Gullberg, Grant T; Aparici, Carina Mari

    2013-01-01

    Cardiac single photon emission computed tomography (SPECT) cameras typically rotate too slowly around a patient to capture changes in the blood pool activity distribution and provide accurate kinetic parameters. A spatiotemporal iterative reconstruction method to overcome these limitations was investigated. Dynamic rest/stress (99m)Tc-methoxyisobutylisonitrile ((99m)Tc-MIBI) SPECT/CT was performed along with reference standard rest/stress dynamic positron emission tomography (PET/CT) (13)N-NH3 in five patients. The SPECT data were reconstructed using conventional and spatiotemporal iterative reconstruction methods. The spatiotemporal reconstruction yielded improved image quality, defined here as a statistically significant (p<0.01) 50% contrast enhancement. We did not observe a statistically significant difference between the correlations of the conventional and spatiotemporal SPECT myocardial uptake K 1 values with PET K 1 values (r=0.25, 0.88, respectively) (p<0.17). These results indicate the clinical feasibility of quantitative, dynamic SPECT/CT using (99m)Tc-MIBI and warrant further investigation. Spatiotemporal reconstruction clearly provides an advantage over a conventional reconstruction in computing K 1.

  2. [Evaluation of myocardial viability with 201Tl/18F-FDG DISA-SPECT technique in patients with acute myocardial infarction after emergent intracoronary autologous bone marrow mononuclear cells transplantation].

    Science.gov (United States)

    Huang, Rong-chong; Yao, Kang; Qian, Ju-ying; Niu, Yu-hong; Ge, Lei; Chen, Shu-guang; Shi, Hong-cheng; Zhang, Yi-Qi; Sun, Ai-jun; Wang, Ke-qiang; Zou, Yun-zeng; Ge, Jun-bo

    2007-06-01

    To evaluate the myocardial viability with (201)Tl/(18)F-FDG DISA-SPECT technique in patients with acute myocardial infarction underwent emergent intracoronary autologous bone marrow mononuclear cells (BM-MNC) transplantation. Patients with first acute myocardial infarction underwent emergent percutaneous coronary intervention (PCI) were randomized in a 1:1 ratio to either intracoronary transplantation of autologous BM-MNC (n = 20) or to sodium chloride concluding heparin (control, n = 20) via a micro infusion catheter group immediately after PCI. Change in global left ventricular function (LVEF measured by echocardiography) and the myocardial viability detected by (201)Tl/(18)F-FDG DISA-SPECT from baseline and 6-months post transplantation were analyzed. Left ventricular ejection fraction (LVEF) was improved in both groups and the absolute increase (DeltaLVEF) in BM-MNC group was significantly higher than that in control group (7.6% +/- 2.8% vs. 3.0% +/- 2.8%, P DISA-SPECT technique.

  3. Comparison of Channelized Hotelling and Human Observers inDetermining Optimum OS-EM Reconstruction Parameters for MyocardialSPECT

    Energy Technology Data Exchange (ETDEWEB)

    Gilland, Karen L.; Tsui, Benjamin M.W.; Qi, Yujin; Gullberg,Grant T.

    2005-07-01

    The performance of the Channelized Hotelling Observer (CHO)was compared to that of human observers for determining optimumparameters for the iterative OS-EM image reconstruction method for thetask of defect detection in myocardial SPECT images. The optimumparameters were those that maximized defect detectability in the SPECTimages. Low noise, parallel SPECT projection data, with and without ananterior, inferior or lateral LV wall defect, were simulated using theMonte Carlo method. Poisson noise was added to generate noisyrealizations. Data were reconstructed using OS-EM at 1&4subsets/iteration and at 1, 3, 5, 7&9 iterations. Images wereconverted to 2D short-axis slices with integer pixel values. The CHO used3 radially-symmetric, 2D channels, with varying levels of internalobserver noise. For each parameter setting, 600 defect-present and 600defect-absent image vectors were used to calculate the detectabilityindex (dA). The human observers rated the likelihood that a defect waspresent in a specified location. For each parameter setting, the AUC wasestimated from 48 defect-present and 48 defect-absent images. Thecombined human observer results showed the optimum parameter settingcould be in the range 5-36 updates ([number of subsets]/iteration enumber of iterations). The CHO results showed the optimum parametersetting to be 4-5 updates. The performance of the CHO was much moresensitive to the reconstruction parameter setting than was that of thehuman observers. The rankings of the CHO detectability values did notchange with varying levels of internal noise.

  4. Factors affecting the myocardial activity acquired during exercise SPECT with a high-sensitivity cardiac CZT camera as compared with conventional Anger camera

    Energy Technology Data Exchange (ETDEWEB)

    Verger, Antoine; Karcher, Gilles [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); INSERM U947 and Universite de Lorraine, Nancy (France); Nancyclotep experimental imaging platform, Nancy (France); Imbert, Laetitia [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); Nancyclotep experimental imaging platform, Nancy (France); Centre Alexis Vautrin, Department of Radiotherapy, Vandoeuvre (France); Yagdigul, Yalcine; Roch, Veronique [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); Nancyclotep experimental imaging platform, Nancy (France); Fay, Renaud [INSERM, Centre d' Investigation Clinique CIC-P 9501, Nancy (France); Djaballah, Wassila [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); INSERM U947 and Universite de Lorraine, Nancy (France); Rouzet, Francois; Le Guludec, Dominique [AP-HP, Hopital Bichat, Department of Nuclear Medicine, Paris (France); INSERM U 773 and Denis Diderot University, Paris (France); Fourquet, Nicolas [Clinique Pasteur, Toulouse (France); Poussier, Sylvain [INSERM U947 and Universite de Lorraine, Nancy (France); Nancyclotep experimental imaging platform, Nancy (France); Marie, Pierre-Yves [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); Nancyclotep experimental imaging platform, Nancy (France); INSERM U1116 and Universite de Lorraine, Nancy (France); CHU-Nancy, Allee du Morvan, Medecine Nucleaire, Hopital de Brabois, Vandoeuvre-les-Nancy (France)

    2014-03-15

    Injected doses are difficult to optimize for exercise SPECT since they depend on the myocardial fraction of injected activity (MFI) that is detected by the camera. The aim of this study was to analyse the factors affecting MFI determined using a cardiac CZT camera as compared with those determined using conventional Anger cameras. Factors affecting MFI were determined and compared in patients who had consecutive exercise SPECT acquisitions with {sup 201}Tl (84 patients) or {sup 99m}Tc-sestamibi (87 patients) with an Anger or a CZT camera. A predictive model was validated in a group of patients routinely referred for {sup 201}Tl (78 patients) or {sup 99m}Tc-sestamibi (80 patients) exercise CZT SPECT. The predictive model involved: (1) camera type, adjusted mean MFI being ninefold higher for CZT than for Anger SPECT, (2) tracer type, adjusted mean MFI being twofold higher for {sup 201}Tl than for {sup 99m}Tc-sestamibi, and (3) logarithm of body weight. The CZT SPECT model led to a +1 ± 26 % error in the prediction of the actual MFI from the validation group. The mean MFI values estimated for CZT SPECT were more than twofold higher in patients with a body weight of 60 kg than in patients with a body weight of 120 kg (15.9 and 6.8 ppm for {sup 99m}Tc-sestamibi and 30.5 and 13.1ppm for {sup 201}Tl, respectively), and for a 14-min acquisition of up to one million myocardial counts, the corresponding injected activities were only 80 and 186 MBq for {sup 99m}Tc-sestamibi and 39 and 91 MBq for {sup 201}Tl, respectively. Myocardial activities acquired during exercise CZT SPECT are strongly influenced by body weight and tracer type, and are dramatically higher than those obtained using an Anger camera, allowing very low-dose protocols to be planned, especially for {sup 99m}Tc-sestamibi and in non-obese subjects. (orig.)

  5. Impaired myocardial perfusion reserve in microvascular angina (syndrome X): Assessment by vasodilation {sup 99m}Tc-MIBI-SPECT; Einschraenkung der myokardialen Perfusionsreserve bei Mikrovaskular-Angina (Syndrom X): Nachweis durch {sup 99m}Tc-MIBI-SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Langes, K. [Universitaetskrankenhaus Eppendorf, Hamburg (Germany). Abt. fuer Kardiologie; Beuthien-Baumann, B. [Universitaetskrankenhaus Eppendorf, Hamburg (Germany). Abt. fuer Nuklearmedizin; Luebeck, M. [Universitaetskrankenhaus Eppendorf, Hamburg (Germany). Abt. fuer Nuklearmedizin; Fuchs, C. [Universitaetskrankenhaus Eppendorf, Hamburg (Germany). Abt. fuer Nuklearmedizin; Schneider, M.A. [Universitaetskrankenhaus Eppendorf, Hamburg (Germany). Abt. fuer Kardiologie; Volk, C. [Universitaetskrankenhaus Eppendorf, Hamburg (Germany). Abt. fuer Kardiologie; Nienaber, C.A. [Universitaetskrankenhaus Eppendorf, Hamburg (Germany). Abt. fuer Kardiologie

    1996-12-01

    Aim: In 22 patients with typical chest pain and normal coronary arteries (microvascular angina, syndrome X) {sup 99m}Tc-MIBI-SPECT was examined in regard to assess impairment of myocardial perfusion reserve. Method: The study was performed with {sup 99m}Tc-MIBI-SPECT at rest and under vasodilation with dipyridamole. The findings were compared with a normal database. A normal perfusion reserve was said to be an increase >20% of the {sup 99m}Tc-MIBI-activity. Results: In 2/22 (9%) of the patients the perfusion reserve lay >20% i.e. 37%. In 91% of the patients a diminution or even decrease of the perfusion was to be seen. From these 9/22 (41%) of the patients showed a diminution of the {sup 99m}Tc-MIBI by 6%. 11/22 patients had a decrease of the perfusion under vasodilation with dipyridamole i.e. a lower activity of 99mTc-MIBI 13%. Conclusion: Vasodilation {sup 99m}Tc-MIBI-SPECT offers good imaging quality and enables semiquantitative assessment of myocardial perfusion reserve in patients with microvascular angina. (orig.) [Deutsch] Ziel: An 22 Patienten mit typischer Angina pectoris und normalen Koronararterien (Mikrovaskular-Angina, Syndrom X) wurde geprueft, ob mit {sup 99m}Tc-MIBI-SPECT eine Einschraenkung der myokardialen Perfusionsreserve nachweisbar ist. Methode: Die Untersuchung mit {sup 99m}Tc-MIBI-SPECT erfolgte in Ruhe und unter Vasodilatation nach einer Infusion mit Dipyridamol im Vergleich zu einer normalen Datenbank. Eine normale myokardiale Perfusionsreserve wurde bei einer differenziellen {sup 99m}Tc-MIBI-Aufnahme von {>=}20% angesehen. Ergebnisse: 2/22 (9%) der Patienten wiesen eine Perfusionsreserve >20% mit im Mittel 37% auf, 91% der Patienten wiesen eine relativ oder absolut verminderte {sup 99m}Tc-MIBI-Aufnahme unter Vasodilatation auf. Bei 9/22 (41%) Patienten war die Perfusionsreserve relativ gemindert mit einer Zunahme der {sup 99m}Tc-MIBI-Aktivitaet von 6%, bei 11/22 wurde eine Abnahme der {sup 99m}Tc-MIBI-Aktivitaet um 13% unter

  6. Reduction in occupational and patient radiation exposure from myocardial perfusion imaging: impact of stress-only imaging and high-efficiency SPECT camera technology.

    Science.gov (United States)

    Duvall, W Lane; Guma, Krista A; Kamen, Jacob; Croft, Lori B; Parides, Michael; George, Titus; Henzlova, Milena J

    2013-08-01

    Recently introduced high-efficiency SPECT cameras have demonstrated the ability to reduce radiation exposure to patients undergoing myocardial perfusion imaging studies, especially when combined with stress-only imaging protocols. To date there have been no relevant studies examining the reduced occupational radiation exposure to medical staff. We sought to determine whether changes in stress myocardial perfusion imaging protocols and camera technology can reduce the occupational radiation exposure to the staff of a nuclear cardiology laboratory. Monthly radiation dosimeter readings from 4 nuclear technologists, 4 nurses, and 2 administrative employees were analyzed from two 12-mo periods: October 2007-September 2008 (period 1), before the use of high-efficiency SPECT, and October 2010-September 2011 (period 2), after high-efficiency SPECT was introduced. The average monthly dose equivalent in millirems (1 mrem = 0.01 mSv) was recorded from personal dosimeters worn on laboratory coats. The total activity of (99m)Tc used per month, mean (99m)Tc administered activity per patient, average number of patients per month, patient time spent in the laboratory, and proportion of stress-only studies were determined. There were 3,539 patients in period 1 and 3,898 in period 2. An approximately 40% reduction in the dose equivalent across all staff members occurred during this time (-16.9 and -16.2 mrem for nuclear technologists and nurses, respectively; P efficiency SPECT technology and stress-only protocols resulted in a 34.7% reduction in mean total (99m)Tc administered activity between time periods, with camera technology being responsible for 39.2% of the reduction and stress-only protocols for 60.8%. A combination of high-efficiency SPECT technology and selective use of stress-only protocols significantly reduces the occupational radiation dose equivalent to the staff of a nuclear cardiology laboratory.

  7. Correlation of myocardial perfusion SPECT with invasive and computed tomography coronary angiogram.

    Science.gov (United States)

    Shelley, S; Indirani, M; Sathyamurthy, I; Subramanian, K; Priti, N; Harshad, K; Padma, D

    2012-01-01

    The consequences of atherosclerosis can be detected by multislice computed tomography (MSCT), invasive coronary angiogram (CAG) and the resultant myocardial ischaemia by myocardial perfusion single photon emission computed tomography (MPS). In this study an attempt is made to compare MSCT with MPS and also to compare the MSCT findings with that of invasive CAG in patients suspected to have coronary artery disease (CAD). A total of 99 patients suspected to have CAD underwent both MSCT and MPS with (99m)Tc sestamibi. The MSCT studies were classified as having no CAD, significant CAD (>50% diameter stenosis), and insignificant CAD (50% diameter stenosis). Multislice computed tomography correlated well in 46 (84%) with P value of 800). Myocardial perfusion single photon emission computed tomography was normal in 15 (27%) coronaries. Myocardial perfusion single photon emission computed tomography provides functional information of the anatomical lesions and MSCT provides anatomical information. Both are two different diagnostic modalities. The MSCT has high NPV in patients with less likelihood for CAD. When compared with CAG, the correlation with MSCT was good and is useful where the calcium score is low. Copyright © 2012 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  8. Reduced coronary flow reserve in patients with primary hyperparathyroidism: a study by G-SPECT myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Marini, Cecilia [CNR Institute of Bioimages and Molecular Physiology Milan, Genoa (Italy); Giusti, Massimo; Vera, Lara; Minuto, Francesco [University of Genoa, Department of Endocrinological and Metabolic Sciences, Genoa (Italy); Armonino, Riccardo; Ghigliotti, Giorgio; Bezante, Gian Paolo; Morbelli, Silvia; Pomposelli, Elena; Massollo, Michela; Gandolfo, Patrizia; Sambuceti, Gianmario [University of Genoa, Department of Internal Medicine, Genoa (Italy)

    2010-12-15

    The mechanisms underlying increased cardiovascular risk in primary hyperparathyroidism (pHPT) have not been fully defined. Recently, this issue has become the subject of renewed interest due to the increasing evidence that the endothelium and vascular wall are targets for parathyroid hormone (PTH). The aim of this study was to measure regional coronary flow reserve (CFR) to determine whether the vascular damage induced by pHPT extends to affect the coronary microvascular function. A total of 22 pHPT patients without a history of coronary artery disease and 7 age-matched control subjects were recruited. Dipyridamole myocardial blood flow (MBF) was assessed using {sup 99m}Tc-sestamibi by measuring first-transit counts in the pulmonary artery and myocardial count rate from G-SPECT images. Baseline MBF was estimated 2 h later according to the same procedure. Regional CFR was defined as the ratio between dipyridamole and baseline MBF using a 17-segment left ventricular model. Three pHPT patients showed reversible perfusion defects and were excluded from the analysis. In the remaining 19, CFR was significantly lower with respect to the control subjects (1.88 {+-} 0.64 vs. 3.36 {+-} 0.66, respectively; p < 0.01). Moreover, patients studied for more than 28 months from pHPT diagnosis showed lower CFR values than the others (1.42 {+-} 0.18 vs. 2.25 {+-} 0.64, respectively; p < 0.01). Consequently, the time from diagnosis to the nuclear study showed a reasonable correlation with the degree of CFR impairment (Spearman's rho -0.667, p < 0.02). pHPT is associated with a significant dysfunction of the coronary microcirculation. This disorder might contribute to the high cardiovascular risk of conditions characterized by chronic elevations in serum PTH levels. (orig.)

  9. Impact of a regimented aminophylline administration protocol on the burden of regadenoson-induced ischemia detected by SPECT myocardial perfusion imaging.

    Science.gov (United States)

    Fughhi, Ibtihaj; Campagnoli, Tania; Ali, Amjad; Doukky, Rami

    2017-10-01

    In patients undergoing regadenoson SPECT myocardial perfusion imaging (MPI), it is unknown how soon and at which dose intravenous aminophylline can be administered to reverse regadenoson-related adverse effects without blunting stress-induced myocardial ischemia. We analyzed the pooled database of the ASSUAGE and ASSUAGE-CKD trials (n = 548). These were double-blinded, placebo-controlled, randomized clinical trials in which 75 mg of aminophylline or placebo was administered intravenously 90 seconds following 99m Tc-tetrofosmin injection. There were no statistically significant differences in summed difference score (SDS) burden (P = .87) and in the rates of myocardial ischemia (SDS ≥ 2) (P = .93) between the aminophylline (n = 274) and placebo (n = 274) groups. There was no interaction between aminophylline use and SDS as a determinant of the composite endpoint of cardiac death or MI (P = .32) or the composite endpoint of cardiac death, MI, or coronary revascularization (P = .92). In patients undergoing regadenoson-stress SPECT-MPI, the intravenous administration of 75 mg of aminophylline as early as 90 seconds after radioisotope injection does not seem to attenuate the burden of myocardial ischemia.

  10. An open-source framework of neural networks for diagnosis of coronary artery disease from myocardial perfusion SPECT.

    Science.gov (United States)

    Guner, Levent A; Karabacak, Nese Ilgin; Akdemir, Ozgur U; Karagoz, Pinar Senkul; Kocaman, Sinan A; Cengel, Atiye; Unlu, Mustafa

    2010-06-01

    The purpose of this study is to develop and analyze an open-source artificial intelligence program built on artificial neural networks that can participate in and support the decision making of nuclear medicine physicians in detecting coronary artery disease from myocardial perfusion SPECT (MPS). Two hundred and forty-three patients, who had MPS and coronary angiography within three months, were selected to train neural networks. Six nuclear medicine residents, one experienced nuclear medicine physician, and neural networks evaluated images of 65 patients for presence of coronary artery stenosis. Area under the curve (AUC) of receiver operating characteristics analysis for networks and expert was .74 and .84, respectively. The AUC of the other physicians ranged from .67 to .80. There were no significant differences between expert, neural networks, and standard quantitative values, summed stress score and total stress defect extent. The open-source neural networks developed in this study may provide a framework for further testing, development, and integration of artificial intelligence into nuclear cardiology environment.

  11. Two-position supine/prone myocardial perfusion SPECT (MPS) imaging improves visual inter-observer correlation and agreement.

    Science.gov (United States)

    Arsanjani, Reza; Hayes, Sean W; Fish, Mathews; Shalev, Aryeh; Nakanishi, Rine; Thomson, Louise E J; Friedman, John D; Germano, Guido; Berman, Daniel S; Slomka, Piotr

    2014-08-01

    We aimed to compare the inter-observer agreement between two experienced readers using supine vs combined supine/prone myocardial perfusion SPECT (MPS) in a large population. 1,181 consecutive patients without known coronary artery disease (CAD) undergoing rest (201)Tl/stress (99m)Tc-sestamibi MPS studies were evaluated. Visual reads were performed in two consecutive steps, with readers scoring the stress supine perfusion images during step 1 and rescoring the images using both supine/prone data during step 2. Visual summed stress scores (SSS) of two readers including regional scores in different vascular territories were compared. The specificity for both readers improved using combined supine/prone imaging (reader 1: 92% vs 86% [P = .0002], reader 2: 88% vs 72% [P only reading. The overall correlation between SSS scores for two readers improved with supine/prone imaging for both genders, as well as in the left anterior descending and right coronary territories. The inter-observer correlation and agreement significantly improve using two-position supine/prone vs supine-only imaging.

  12. Influence of attenuation correction on transient left ventricular dilation in dual isotope myocardial perfusion imaging in patients with known or suspected coronary artery disease.

    Science.gov (United States)

    Brodov, Yafim; Frenkel, Alex; Chouraqui, Pierre; Przewloka, Kinga; Rispler, Shmuel; Abadi, Sobhi; Keidar, Zohar

    2012-07-01

    The aim of this study was to assess the effect of attenuation correction (AC) on left ventricular (LV) volumes and LV transient ischemic dilatation (TID) during dual-isotope single-photon emission computer tomographic (SPECT) myocardial perfusion imaging (MPI). Ninety-six patients (mean age 58 ± 11 years, 15% women, 38 patients completed exercise and 58 dipyridamole pharmacologic stress tests) assessed for known or suspected coronary artery disease underwent dual-isotope thallium-201 rest and technetium-99m sestamibi stress SPECT MPI with computed tomography-based AC. The TID ratio was calculated separately for non-AC and AC SPECT MPI studies as the ratio of the LV endocardial volume at stress divided by LV endocardial volume at rest. The mean and range of the gated LV ejection fraction during exercise and pharmacologic stress was 54 ± 12% (29% to 80%) and 58 ± 12% (27% to 80%), respectively. In the exercise stress group, the same mean LV endocardial volumes in non-AC and AC stress (76.4 ± 30 and 76.5 ± 28) and rest (66.3 ± 26 and 66.4 ± 24) studies were found (p = 0.90). There was no statistical difference between the mean exercise TID ratio in non-AC and AC studies (1.27 vs 1.31, respectively, p = 0.10). The same mean LV endocardial volumes in non-AC and AC in pharmacologic stress (79.9 ± 42 and 80 ± 41) and rest (71.4 ± 41 and 72.3 ± 37), respectively, were found (p = 0.50). There was no statistical difference between the mean dipyridamole TID ratio in non-AC and AC studies (1.20 vs 1.17, respectively, p = 0.10). In conclusion, LV volumes and TID indexes obtained on SPECT MPI with exercise or pharmacologic stress using dipyridamole are not affected by AC. Copyright © 2012 Elsevier Inc. All rights reserved.

  13. Prognostic Value of Myocardial Perfusion Imaging with a Cadmium-Zinc-Telluride SPECT Camera in Patients Suspected of Having Coronary Artery Disease.

    Science.gov (United States)

    Engbers, Elsemiek M; Timmer, Jorik R; Mouden, Mohamed; Knollema, Siert; Jager, Pieter L; Ottervanger, Jan Paul

    2017-09-01

    The prognostic value of myocardial perfusion imaging (MPI) with the cadmium-zinc-telluride (CZT) SPECT camera is not well established. Therefore, the aim of the current study was to evaluate the prognostic value of MPI performed with a CZT SPECT camera in a large cohort of patients suspected of having coronary artery disease. Methods: Consecutive symptomatic stable patients (n = 4,057) without a history of coronary artery disease underwent CZT SPECT MPI. During a median follow-up of 2.4 y (25th-75th percentile, 1.7-3.4), patients were monitored for primary (nonfatal myocardial infarction and cardiac mortality) and secondary outcomes (late revascularization [>90 d after scanning] and primary outcome). Results: Patients with normal perfusion demonstrated low annual event rates (primary outcome, 0.2%; secondary outcome, 0.6%). Annual event rates increased with the extent of abnormality of myocardial perfusion. In patients with small ischemic perfusion defects, annual event rates were 0.7% and 2.8% for the primary and secondary outcome, respectively. In patients with moderate or large ischemic perfusion defects, these event rates were 1.2% and 4.3%, respectively. After multivariate analysis, the risk for events was significantly associated with the extent of ischemia (hazard ratio for small ischemic defects: 2.2, 95% confidence interval [CI], 0.9-5.9 and 4.6, 95% CI, 2.8-7.6, for primary and secondary outcomes, respectively; hazard ratio for moderate or large ischemic defects: 4.0, 95% CI, 1.5-10.5 and 12.1, 95% CI, 7.2-20.2, for primary and secondary outcomes, respectively). Conclusion: Our findings show that MPI acquired with a CZT SPECT camera provides excellent prognostic information, with low event rates in patients with normal myocardial perfusion. In patients with abnormal SPECT MPI, the extent of abnormality is independently associated with an increased risk of events. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  14. Assessment of functional effects using gated myocardial perfusion SPECT after mesenchymal stem cells transplantation in a porcine model of myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Heo, Young Jun; Ahn, Young Eun; Lim, Sang Yup; Song, Ho Chun; Bom, Hee Seung; Min, Joeng Jun; Jeong, Myung Ho; Cho, Jeong Gwan; Park, Jong Chun; K, Jung Chaee [School of Medicine, Chonnam National University, Gwangju (Korea, Republic of)

    2004-07-01

    Bone-marrow-derived Mesenchymal stem cells(MSCs) have shown therapeutic potential of successfully delivered to the intended site of myocardial infarction. The purpose of study is to test the feasibility and usefulness of gated myocardial perfusion SPECT(GSPECT) in the evaluation of the function and perfusion of the left ventricle(LV) after transplantation of MSCs transduced with Akt in a porcine model of myocardial infarction(MI). MSCs were separated from hematopoietic cells based on their preferential attachment to polystyrene surfaces and genetically engineered using ex-vivo myr-Akt-adenoviral gene transfer. MSCs were delivered by intracoronary injection to adult farm pigs (n=15) after MI [group I(control:n=5), media only:group II(n=5), MSCs only:group III(n=5), MSCs modified with Akt]. GSPECT with Tc-99m tetrofosmin was done before and 4 weeks after MSC transplantation. LV volume, left ventricular ejection fraction(LVEF) and area of MI were calculated from the GSPECT data by QGS. Pigs were sacrificed for immunocytochemical characterization. Mean LVEF was 44.8{+-}16.6%, 29.8{+-}7.6%, and 41.2{+-}8.3% at first (each n=5) and changed to 29.8{+-}8.5%, 39.0{+-}9.5%, and 60.1{+-}17.4% at 4 weeks after the MSC implantation in group I, II, and III, respectively. Mean MI area was 17.6{+-}9.2%, 35.0{+-}11.8%, and 24.3{+-}11.2% at first, and changed to 19.6{+-}10.1%, 27.2{+-}13.9%, and 7.4{+-}5.3% in group I, II, and III, respectively. Transplantation of {approx}107cells into the ischemic porcine myocardium in group II increased the LVEF (-14.9{+-}15.3% versus 9.0{+-}8.6%, n=5 in each, p=0.016) and decreased the area of MI (2.1{+-}1.3% versus -7.9{+-}9.0%, n=5 in each, p=0.04) compared with control group and much more different in group III in LVEF (19.2{+-}16.4%, p=0.006) and in area of MI (-16.3{+-}6.4%, p=0.037). GSPECT is useful to estimate the functional effects on repair of the injured area, remodeling, and systolic performance in infarcted hearts after the

  15. The significance of automatically measured transient ischemic dilation in identifying severe and extensive coronary artery disease in regadenoson, single-isotope technetium-99m myocardial perfusion SPECT.

    Science.gov (United States)

    Golzar, Yasmeen; Olusanya, Adebayo; Pe, Nadith; Dua, Sumeet G; Golzar, Jaafer; Gidea, Claudia; Doukky, Rami

    2015-06-01

    The critical threshold and clinical significance of transient ischemic dilation (TID) for regadenoson, single-isotope (99m)Tc SPECT myocardial perfusion imaging (MPI) are not defined. From 100 patients with low likelihood of CAD, we derived the abnormal TID threshold (mean + 2 SD). We validated the threshold in a cohort of 547 patients who received one-day, rest/regadenoson-stress, (99m)Tc-tetrofosmin SPECT-MPI followed by coronary angiography within 6 months. Patients were classified into three CAD severity strata: no significant CAD, mild to moderate CAD, and severe and extensive CAD. The abnormal TID threshold was determined to be 1.31. Though mean TID ratios were different between the three CAD severity groups and the derivation cohort (P regadenoson-stress MPI in this era of declining CAD burden is questionable.

  16. Superior diagnostic performance of perfusion-cardiovascular magnetic resonance versus SPECT to detect coronary artery disease: The secondary endpoints of the multicenter multivendor MR-IMPACT II (Magnetic Resonance Imaging for Myocardial Perfusion Assessment in Coronary Artery Disease Trial)

    Science.gov (United States)

    2012-01-01

    Background Perfusion-cardiovascular magnetic resonance (CMR) is generally accepted as an alternative to SPECT to assess myocardial ischemia non-invasively. However its performance vs gated-SPECT and in sub-populations is not fully established. The goal was to compare in a multicenter setting the diagnostic performance of perfusion-CMR and gated-SPECT for the detection of CAD in various populations using conventional x-ray coronary angiography (CXA) as the standard of reference. Methods In 33 centers (in US and Europe) 533 patients, eligible for CXA or SPECT, were enrolled in this multivendor trial. SPECT and CXA were performed within 4 weeks before or after CMR in all patients. Prevalence of CAD in the sample was 49% and 515 patients received MR contrast medium. Drop-out rates for CMR and SPECT were 5.6% and 3.7%, respectively (ns). The study was powered for the primary endpoint of non-inferiority of CMR vs SPECT for both, sensitivity and specificity for the detection of CAD (using a single-threshold reading), the results for the primary endpoint were reported elsewhere. In this article secondary endpoints are presented, i.e. the diagnostic performance of CMR versus SPECT in subpopulations such as multi-vessel disease (MVD), in men, in women, and in patients without prior myocardial infarction (MI). For diagnostic performance assessment the area under the receiver-operator-characteristics-curve (AUC) was calculated. Readers were blinded versus clinical data, CXA, and imaging results. Results The diagnostic performance (= area under ROC = AUC) of CMR was superior to SPECT (p = 0.0004, n = 425) and to gated-SPECT (p = 0.018, n = 253). CMR performed better than SPECT in MVD (p = 0.003 vs all SPECT, p = 0.04 vs gated-SPECT), in men (p = 0.004, n = 313) and in women (p = 0.03, n = 112) as well as in the non-infarct patients (p = 0.005, n = 186 in 1–3 vessel disease and p = 0.015, n = 140 in MVD). Conclusion

  17. Prognostic risk stratification of myocardial ischaemia evaluated by gated myocardial perfusion SPECT in patients with chronic kidney disease

    Energy Technology Data Exchange (ETDEWEB)

    Hatta, Tsuguru [Ohmihachiman Community Medical Center, Division of Nephrology, Department of Medicine, Shiga (Japan); Nishimura, Shigeyuki [Saitama Medical School Hospital, Division of Cardiology, Saitama (Japan); Nishimura, Tsunehiko [Kyoto Prefectural University of Medicine, Department of Radiology, Graduate School of Medical Science, Kyoto (Japan)

    2009-11-15

    The aim of this study was to identify useful predictors of cardiac events in patients with chronic kidney disease (CKD). Among 4,031 patients identified from the Japanese Assessment of Cardiac Events and Survival Study (J-ACCESS) database with suspected or known ischaemic heart disease, we selected 820 with an estimated glomerular filtration rate (eGFR) of < 60 ml/min per 1.73 m{sup 2}. A total of 75 cardiac events developed among these 820 patients. The incidence of cardiac events was higher in the group with a lower eGFR. Multivariate Cox analysis indicated that age, diabetes mellitus, end-systolic volume, summed stress score (SSS) and eGFR were predictors of cardiac events. Event rates of patients with SSS {>=} 9 were significantly higher in groups with lower eGFR values (< 40 and 40-49 ml/min). The SSS value ({>=} 9) is a reliable predictor of cardiac events and myocardial single photon emission computed tomography has incremental value for predicting cardiac events and survival in CKD. (orig.)

  18. Potential diagnostic value of regional myocardial adrenergic imaging using {sup 123}I-MIBG SPECT to identify patients with Lewy body diseases

    Energy Technology Data Exchange (ETDEWEB)

    Lebasnier, Adrien; Peyronnet, Damien; Bouvard, Gerard [University Hospital Center of Caen, Department of Nuclear Medicine, Caen (France); Lamotte, Guillaume; Defer, Gilles [University Hospital Center of Caen, Department of Neurology, Caen (France); Manrique, Alain [University Hospital Center of Caen, Department of Nuclear Medicine, Caen (France); Cyceron PET Centre, Caen (France); Normandie Universite, Caen (France); Agostini, Denis [University Hospital Center of Caen, Department of Nuclear Medicine, Caen (France); Normandie Universite, Caen (France)

    2015-01-28

    The aim of this study was to determine the potential diagnostic value of regional myocardial adrenergic {sup 123}I-metaiodobenzylguanidine (MIBG) single photon emission computed tomography (SPECT) imaging to identify patients with Lewy body diseases (LBD+). Sixty-four consecutive patients who underwent cardiac {sup 123}I-MIBG SPECT to differentiate LBD+, including Parkinson's disease (PD) and dementia with Lewy bodies (DLB), from patients without LBD (LBD-) were retrospectively reviewed. A neurologist expert in memory disorders determined the final clinical diagnosis by using international clinical diagnostic criteria. Planar [heart to mediastinum ratio (HMR)] and {sup 123}I-MIBG SPECT[innervation defect score (IDS)] using the 17-segment left ventricular model (five-point scale) were obtained 4 h after the injection of {sup 123}I-MIBG on a low-energy high-resolution (LEHR) collimator. Receiver-operating characteristic (ROC) analysis was performed to determine the optimal HMR and IDS cut-off values to discriminate LBD+ from LBD-. Of the 64 patients, 45 (70 %) were diagnosed LBD+ (DLB, n = 27; PD, n = 18) and 19 were diagnosed LBD- (5 other dementias, 14 other parkinsonisms). The HMR and IDS of LBD+ were significantly different from those of LBD- (1.30 ± 0.21 vs 1.65 ± 0.26, p < 0.001; 39 ± 28 vs 8 ± 16, p = 0.001). The optimal HMR and IDS cut-off values to discriminate LBD+ (n = 45) from LBD- (n = 19) were 1.47 and 6/68, providing a sensitivity and specificity of 82.2 and 84.2 % and 86.7 and 73.7 %, respectively. Regional myocardial adrenergic {sup 123}I-MIBG imaging SPECT has a potential diagnostic value to identify LBD+. (orig.)

  19. Diagnostic accuracy of cadmium-zinc-telluride-based myocardial perfusion SPECT: impact of attenuation correction using a co-registered external computed tomography.

    Science.gov (United States)

    Caobelli, Federico; Akin, Muharrem; Thackeray, James T; Brunkhorst, Thomas; Widder, Julian; Berding, Georg; Burchert, Ina; Bauersachs, Johann; Bengel, Frank M

    2016-09-01

    Computed tomography (CT)-based attenuation correction (AC) improves the accuracy of standard myocardial perfusion SPECT. Most dedicated cadmium-zinc-telluride (CZT) SPECT cameras are not equipped with an integrated CT component. We aimed to determine the impact of AC on diagnostic performance of CZT SPECT using co-registration with an external low-dose CT. Sixty patients underwent CZT SPECT (GE Discovery 530c) with (99m)Tc-sestamibi at rest and following regadenoson stress. Using commercial software, SPECT images were co-registered with a low-dose CT acquired on a separate system (GE Discovery 670NMCT). Attenuation corrected and non-corrected (NC) images were reconstructed using an iterative algorithm. Accuracy was measured in 44 patients who had undergone invasive angiography within 6 months. Normalcy was compared in the remaining 16 patients who had a low pre-test likelihood (<5%) of coronary artery disease (CAD). Summed stress and rest scores were significantly lower in AC images (9 ± 8 vs. 13 ± 9 and 6 ± 7 vs. 10 ± 9, P = 0.01), while summed difference score did not differ. According to angiography, 38 patients had significant CAD in 71 vascular territories. Attenuation correction improved accuracy globally (P = 0.03) and in RCA territory (P = 0.008). Specificity improved both globally (100 vs. 40%, P < 0.05) and in each individual territory (LAD: 63 vs. 36%, LCX: 70 vs. 33%, RCA: 81 vs. 19%, P < 0.01). Normalcy was 100% for AC and 62.5% for NC images (P < 0.05). Attenuation correction with a co-registered external CT is feasible using CZT cameras and improves diagnostic accuracy mostly by improving specificity over uncorrected images. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  20. Rest myocardial perfusion/metabolism imaging using simultaneous dual-isotope acquisition SPECT with technetium-99m-MIBI/fluorine-18-FDG.

    Science.gov (United States)

    Delbeke, D; Videlefsky, S; Patton, J A; Campbell, M G; Martin, W H; Ohana, I; Sandler, M P

    1995-11-01

    The purpose of this study was to develop a dual-isotope simultaneous acquisition (DISA) protocol using a multihead SPECT camera equipped with an ultrahigh-energy (UHE) collimator to evaluate simultaneously rest cardiac perfusion and metabolism with 99mTc-MIBI/18FDG. Physical measurements were first performed with phantoms to develop the acquisition protocol. Fifteen patients underwent DISA-SPECT with 99mTc-MIBI/18FDG to validate the protocol. To evaluate the quality of the 99mTc-MIBI images acquired with the UHE collimator, four patients underwent a resting 99mTc-MIBI scan acquired with a high-resolution, low-energy collimator prior to DISA-SPECT. With a window of 20% for both photopeaks and a 99mTc/18F concentration ratio of 3.2:1, the spillover from 18F into the 99mTc window is 6% of the counts in the window for normal subjects. Phantom images clearly demonstrated defects measuring 2 x 1 and 2 x 0.5 cm. Technetium-99m-MIBI images obtained with the UHE and high-resolution collimators provided similar diagnostic information. Using a stenosis of > 70% as criteria to diagnose coronary artery disease, DISA-SPECT had a sensitivity of 100% and a positive predictive value of 93%. Simultaneous evaluation of rest myocardial perfusion/metabolism with a multihead SPECT camera equipped with an UHE collimator is possible using 99mTc-MIBI/18FDG with a dual-isotope simultaneous acquisition protocol.

  1. Quantitative evaluation of myocardial stress/rest 201TL SPECT: results of a ROI-based method in 108 patients with CHD.

    Science.gov (United States)

    Buell, U; Stirner, H; vom Dahl, J; Uebis, R; Kleinhans, E; Biedermann, M; Grosse, W; Simon, H J

    1987-12-01

    ROI-based polar maps (33 ROIs) were employed to evaluate quantitatively stress/rest myocardial 201Tl SPECT in 108 patients with angiographically proven coronary heart disease (CHD) in comparison with 30 controls. Sensitivity in detecting a CHD with stenoses of greater than 50% of luminal diameter was determined versus normal regional values (+/- 2.5 SD) employing vitality (VI) and wash-out corrected redistribution (RD). The method was evaluated referring to the severity of the disease, to the number of ROIs displaying changes [(a) 1 ROI, (b) greater than 2 ROIs], to validity of VI, RD or a combination thereof, and for specificity. Wash-out values were found to depend on degree of stress individually achieved and thus were not used as a threshold criterion. Sensitivity in supply areas with old myocardial infarctions was 95% (a) and 86% (b), resp. With no infarction, it was 96% (a) and 79% (b), resp. VI in stenosis greater than 75% was more sensitive than RD. However, combined evaluation of VI and RD yielded sensitivities from 91-100% (a) and 77-94% (b), resp. for different main supply areas. In stenosis less than 50% with normal VI, RD was positive in 18-31%. Specificity turned out to be 91% (a) and 97% (b), resp. We conclude that the method presented is reliable to quantify numerically 201Tl kinetics in myocardial SPECT, aimed at detecting and describing CHD.

  2. Prediction of revascularization after myocardial perfusion SPECT by machine learning in a large population.

    Science.gov (United States)

    Arsanjani, Reza; Dey, Damini; Khachatryan, Tigran; Shalev, Aryeh; Hayes, Sean W; Fish, Mathews; Nakanishi, Rine; Germano, Guido; Berman, Daniel S; Slomka, Piotr

    2015-10-01

    We aimed to investigate if early revascularization in patients with suspected coronary artery disease can be effectively predicted by integrating clinical data and quantitative image features derived from perfusion SPECT (MPS) by machine learning (ML) approach. 713 rest (201)Thallium/stress (99m)Technetium MPS studies with correlating invasive angiography with 372 revascularization events (275 PCI/97 CABG) within 90 days after MPS (91% within 30 days) were considered. Transient ischemic dilation, stress combined supine/prone total perfusion deficit (TPD), supine rest and stress TPD, exercise ejection fraction, and end-systolic volume, along with clinical parameters including patient gender, history of hypertension and diabetes mellitus, ST-depression on baseline ECG, ECG and clinical response during stress, and post-ECG probability by boosted ensemble ML algorithm (LogitBoost) to predict revascularization events. These features were selected using an automated feature selection algorithm from all available clinical and quantitative data (33 parameters). Tenfold cross-validation was utilized to train and test the prediction model. The prediction of revascularization by ML algorithm was compared to standalone measures of perfusion and visual analysis by two experienced readers utilizing all imaging, quantitative, and clinical data. The sensitivity of machine learning (ML) (73.6% ± 4.3%) for prediction of revascularization was similar to one reader (73.9% ± 4.6%) and standalone measures of perfusion (75.5% ± 4.5%). The specificity of ML (74.7% ± 4.2%) was also better than both expert readers (67.2% ± 4.9% and 66.0% ± 5.0%, P revascularization after MPS, and is significantly better than standalone measures of perfusion derived from MPS.

  3. Quantitative I-123 mIBG SPECT in differentiating abnormal and normal mIBG myocardial uptake.

    Science.gov (United States)

    Chen, Ji; Folks, Russell D; Verdes, Liudmila; Manatunga, Daya N; Jacobson, Arnold F; Garcia, Ernest V

    2012-02-01

    The purpose of this study was to evaluate global quantitation of cardiac uptake on I-123 mIBG SPECT. The study included a pilot group of 67 subjects and a validation group of 1,051 subjects. SPECT images were reconstructed by filtered backprojection, ordered subsets expectation maximization, and deconvolution of septal penetration, respectively. SPECT heart-to-mediastinum ratio (H/M) was calculated by comparing the mean counts between heart and mediastinum volumes of interest drawn on transaxial images. Receiver operating characteristic (ROC) analysis was used to assess the capability of each SPECT method to differentiate the heart disease subjects from controls in comparison with that of the planar H/M. In the validation group, the areas under the ROC curves were not significantly different between the SPECT and planar H/M. Order subsets expectation maximization had significantly larger area under the ROC curve than the other two SPECT methods. H/M obtained from I-123 mIBG SPECT was equivalent to the planar H/M for differentiating between subjects with normal and abnormal mIBG uptake. Global quantification of cardiac I-123 mIBG SPECT may represent a viable alternative to the planar H/M.

  4. Clinical usefulness of {sup 123}I-MIBG myocardial spect in patients with cardiac sarcoidosis

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Keiko; Hatsumi, Chie; Fujioka, Haruto [Juntendo Univ., Tokyo (Japan). School of Medicine] [and others

    1996-09-01

    This study was undertaken to assess whether {sup 123}I-MIBG scintigraphy is useful to detect cardiac involvements of sarcoidosis. In 45 patients with sarcoidosis, dual SPECT with {sup 123}I-MIBG and {sup 201}Tl-Cl(Tl) were performed, and the findings were compared with electrocardiogram (ECG), 24 hour Holter ECG and ultrasound echocardiography. In order to evaluate cardiac involvements, Tl and MIBG extent score (E.S.) and severity score (S.S.) were calculated by a Bull`s eye map in addition to visual evaluation. Abnormal findings were recognized in 8.9% of all subjects in echocardiography, in 22.2% of those in ECG and Holter ECG, in 40% of those in Tl scintigraphy, and in 64.4% of those in MIBG scintigraphy. All of the Tl and MIBG abnormalities were detected in left ventricles, especially at the basal septal wall. At the inferior wall, abnormalities were observed more frequently by MIBG than by Tl. Tl E.S., Tl S.S. and MIBG E.S. were significantly higher in 10 patients with abnormal ECG findings than in 35 patients with normal ECG findings. Also, all of 10 patients with abnormal ECG findings had abnormal MIBG image, but 3 of them showed normal Tl images. 11 of 35 patients with normal ECG findings showed abnormal Tl and MIBG images (group A), 8 of 35 patients showed normal Tl images and abnormal MIBG images (group B), and 16 of 35 patients showed normal Tl and MIBG images (group C). MIBG S.S. of group A (11.3{+-}7.8) was significantly higher than that of group B (5.3{+-}3.1) or group C (2.6{+-}3.2). Furthermore, in group A, MIBG S.S. was significantly higher than Tl S.S. (5.5{+-}2.8). In a case of normal ECG with abnormal MIBG images, we seriously suspect cardiac involvements and recommend repeated Holter ECG tests as necessary in order to detect critical arrythmia. MIBG scintigraphy appeared to be a sensitive and useful method for the early detection of cardiac sarcoidosis. (J.P.N.)

  5. Ventricular dyssynchrony assessed by gated myocardial perfusion SPECT using a geometrical approach: a feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Veen, Berlinda J. van der; Younis, Imad Al [Leiden University Medical Centre, Department of Nuclear Medicine, Leiden (Netherlands); Ajmone-Marsan, Nina; Bax, Jeroen J. [Leiden University Medical Centre, Department of Cardiology, Leiden (Netherlands); Westenberg, Jos J.M.; Roos, Albert de [Leiden University Medical Centre, Department of Radiology, Leiden (Netherlands); Stokkel, Marcel P.M. [Antoni van Leeuwenhoek Hospital, Department of Nuclear Medicine, Netherlands Cancer Institute, Amsterdam (Netherlands)

    2012-03-15

    Left ventricular dyssynchrony may predict response to cardiac resynchronization therapy and may well predict adverse cardiac events. Recently, a geometrical approach for dyssynchrony analysis of myocardial perfusion scintigraphy (MPS) was introduced. In this study the feasibility of this geometrical method to detect dyssynchrony was assessed in a population with a normal MPS and in patients with documented ventricular dyssynchrony. For the normal population 80 patients (40 men and 40 women) with normal perfusion (summed stress score {<=}2 and summed rest score {<=}2) and function (left ventricular ejection fraction 55-80%) on MPS were selected; 24 heart failure patients with proven dyssynchrony on MRI were selected for comparison. All patients underwent a 2-day stress/rest MPS protocol. Perfusion, function and dyssynchrony parameters were obtained by the Corridor4DM software package (Version 6.1). For the normal population time to peak motion was 42.8 {+-} 5.1% RR cycle, SD of time to peak motion was 3.5 {+-} 1.4% RR cycle and bandwidth was 18.2 {+-} 6.0% RR cycle. No significant gender-related differences or differences between rest and post-stress acquisition were found for the dyssynchrony parameters. Discrepancies between the normal and abnormal populations were most profound for the mean wall motion (p value <0.001), SD of time to peak motion (p value <0.001) and bandwidth (p value <0.001). It is feasible to quantify ventricular dyssynchrony in MPS using the geometrical approach as implemented by Corridor4DM. (orig.)

  6. Geometric feature-based multimodal image registration of contrast-enhanced cardiac CT with gated myocardial perfusion SPECT.

    Science.gov (United States)

    Woo, Jonghye; Slomka, Piotr J; Dey, Damini; Cheng, Victor Y; Hong, Byung-Woo; Ramesh, Amit; Berman, Daniel S; Karlsberg, Ronald P; Kuo, C-C Jay; Germano, Guido

    2009-12-01

    Cardiac computed tomography (CT) and single photon emission computed tomography (SPECT) provide clinically complementary information in the diagnosis of coronary artery disease (CAD). Fused anatomical and physiological data acquired sequentially on separate scanners can be coregistered to accurately diagnose CAD in specific coronary vessels. A fully automated registration method is presented utilizing geometric features from a reliable segmentation of gated myocardial perfusion SPECT (MPS) volumes, where regions of myocardium and blood pools are extracted and used as an anatomical mask to de-emphasize the inhomogeneities of intensity distribution caused by perfusion defects and physiological variations. A multiresolution approach is employed to represent coarse-to-fine details of both volumes. The extracted voxels from each level are aligned using a similarity measure with a piecewise constant image model and minimized using a gradient descent method. The authors then perform limited nonlinear registration of gated MPS to adjust for phase differences by automatic cardiac phase matching between CT and MPS. For phase matching, they incorporate nonlinear registration using thin-plate-spline-based warping. Rigid registration has been compared with manual alignment (n=45) on 20 stress/rest MPS and coronary CTA data sets acquired from two different sites and five stress CT perfusion data sets. Phase matching was also compared to expert visual assessment. As compared with manual alignment obtained from two expert observers, the mean and standard deviation of absolute registration errors of the proposed method for MPS were4.3±3.5, 3.6±2.6, and 3.6±2.1mm for translation and 2.1±3.2°, 0.3±0.8°, and 0.7±1.2° for rotation at site A and 3.8±2.7, 4.0±2.9, and 2.2±1.8mm for translation and 1.1±2.0°, 1.6±3.1°, and 1.9±3.8° for rotation at site B. The results for CT perfusion were 3.0±2.9, 3.5±2.4, and 2.8±1.0mm for translation and 3.0±2.4°, 0.6±0.9°, and 1

  7. Dynamic low dose I-123-iodophenylpentadecanoic acid metabolic cardiac imaging; Comparison to myocardial biopsy and reinjection SPECT thallium in ischemic cardiomyopathy and cardiac transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Murray, G.L.; Magill, H.L. [Baptist Memorial Hospital (United States); Schad, N.C.

    1993-12-01

    Recognition of stunned and hibernating myocardium is essential in this era of cardiac revascularization. Positron emission tomography (PET) accurately identifies viability but is costly and unavailable to most patients. Dynamic low dose I-123-iodophenylpentadecanoic acid (IPPA) metabolic cardiac imaging is a potentially cost-effective alternative to PET. Using transmural myocardial biopsies obtained during coronary bypass surgery as the viability gold standard, resting IPPA imaging agreed with 39/43 (91%) biopsies, with a sensitivity for viability of 33/36(92%) and a specificity of 6/7 (86%) in patients with severe ischemic cardiomyopathy. Eighty percent of IPPA viable, infarcted segments improved wall motion postoperatively. Furthermore, when compared to reinjection thallium (SPECT-Tl) scans after myocardial infarction, there was IPPA-Tl concordance in 27/35 (77%)(Kappa=0.536, p=0.0003). Similar to PET, IPPA demonstrated more viability than SPECT-Tl, 26/35 (74%) vs. 18/35 (51%)(p=0.047). Finally, when compared to transvenous endomyocardial biopsy for detecting rejection following cardiac transplantation, IPPA sensitivity for {>=}Grade II rejection was 100%, and IPPA screening assessment for the necessity of biopsy could result in a 31% cost-savings. Therefore, IPPA metabolic cardiac imaging is a safe, inexpensive technique with a promising future. (author).

  8. The impact of regimented aminophylline use on extracardiac radioisotope activity in patients undergoing regadenoson stress SPECT myocardial perfusion imaging: a substudy of the ASSUAGE trial.

    Science.gov (United States)

    Ballany, Wassim; Mansour, Khaled; Morales Demori, Raysa; Al-Amoodi, Mohammed; Doukky, Rami

    2014-06-01

    In patients undergoing regadenoson stress SPECT myocardial perfusion imaging (MPI), the impact of the regimented administration of aminophylline on the cardiac-to-extracardiac photon activity ratio is unknown. This is a substudy of the ASSUAGE trial (NCT01250496); a double-blinded, randomized, placebo-controlled clinical trial which investigated the attenuation of regadenoson-related adverse effects using 75 mg of intravenous aminophylline vs placebo, administered 90 seconds following (99m)Tc-tetrofosmin injection in patients undergoing regadenoson stress SPECT-MPI. In subjects with normal MPI enrolled in the trial, we sampled from the antero-posterior planar projection of the post-stress scintigraphic data the mean photon activity in the myocardium, liver, bowel, and lungs. The mean cardiac-to-extracardiac activity ratios were compared between patients randomized to aminophylline vs placebo. We studied 158 eligible subjects, randomized to receive aminophylline (n = 86) or placebo (n = 72). The means of photon activity ratios of the heart-to-liver, heart-to-bowel, heart-to-lungs, inferior wall of the heart-to-liver, and inferior wall of the heart-to-bowel were not statistically different between those who received aminophylline vs placebo (P values > .30). Only the time lapse between stress (99m)Tc-tetrofosmin injection and stress SPECT acquisition independently correlated with higher heart-to-liver and heart-to-bowel activity ratios (P values ≤ .01). Patients' body mass index independently correlated with lower heart-to-lung ratio (P = .009). The regimented intravenous aminophylline use following regadenoson stress does not significantly improve the cardiac-to-extracardiac photon activity ratio in patients undergoing regadenoson stress (99m)Tc-tetrofosmin SPECT-MPI.

  9. A micro-SPECT imaging pilot study of myocardial perfusion in mice; Etude pilote de la perfusion myocardique chez la souris par micro-imagerie TEMP

    Energy Technology Data Exchange (ETDEWEB)

    Constantinesco, A.; Choquet, P.; Israel-Jost, V. [Hopital de Hautepierre, Service de Biophysique et Medecine Nucleaire, 67 - Strasbourg (France); Israel-Jost, V.; Sonnendrucker, E. [Institut de Recherche Mathematique Avancee de Strasbourg, 67 (France); Monassier, L. [Institut National de la Sante et de la Recherche Medicale (INSERM U333), 67 - Strasbourg (France); Elfertak, L. [Institut Clinique de la Souris (ICS), 67 - Illkirch (France)

    2004-04-01

    Objective: demonstrate the feasibility of micro-SPECT for myocardial perfusion imaging in mice. Methods: a micro-SPECT dedicated camera with a field of view of 17 cm x 17 cm, a 1,5 mm pinhole with a focal distance of 12 cm was used. An infra millimetric linear phantom permitted to measure the planar and tomographic FWHM. Two normal adult mice were studied under gaseous anaesthesia (isoflurane 1,5%) and after IV administration of 0,1 mL of {sup 99m}Tc-Sestamibi (350 MBq) in one case and {sup 201}Tl (64 MBq) in the other case. In the two cases, 48 projections of 1 mn over 180 deg C in a 64 x 64 image format with a radius of rotation of 2,5 cm were used with a 20% window centered on the photoelectric peak of 99mTc or the 71 KeV of {sup 201}Tl. Tomographic reconstruction was done with a specific ART cone beam algorithm. Results: phantoms FWHM were respectively 1.6 mm and 1.5 mm in planar and tomographic modes with a reconstructed field of view of 26 mm and 1 mm when the reconstructed field of view was 10 mm. Micro-SPECT perfusion images using a reconstructed voxel volume of 0.064 mm{sup 3} of the mice myocardium were obtained with a better anatomical resolution with Sestamibi than thallium. Conclusion: this pilot study demonstrate the potential of micro-SPECT imaging for mice nuclear cardiology. (author)

  10. Relationship between infarct size and severity measured by gated SPECT and long-term left ventricular remodelling after acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Berti, Valentina; Sciagra, Roberto; Pupi, Alberto [University of Florence, Nuclear Medicine Unit, Department of Clinical Physiopathology, Florence (Italy); Acampa, Wanda; Ricci, Francesca; Gallicchio, Rosj; Cuocolo, Alberto [University Federico II and Institute of Biostructures and Bioimages of the National Council of Research, Department of Biomorphological and Functional Sciences, Naples (Italy); Cerisano, Giampaolo [Careggi Hospital, Division of Cardiology, Florence (Italy); Vigorito, Carlo [University Federico II, Department of Clinical Medicine, Cardiovascular and Immunological Sciences, Cardiac Rehabilitation Unit, Naples (Italy)

    2011-06-15

    After acute myocardial infarction (AMI), left ventricular (LV) remodelling may occur despite successful reperfusion. This study aimed to investigate by gated single photon emission computed tomography (SPECT) the long-term evolution of myocardial perfusion and LV function after AMI and to identify the predictors of LV remodelling. Sixty-eight AMI patients successfully treated by primary percutaneous coronary intervention underwent {sup 99m}Tc-sestamibi gated SPECT at 1 month (baseline) and over 6-month follow-up after the acute event. LV remodelling was defined as 20% increase in LV end-diastolic volume at follow-up. At baseline, patients with remodelling (n = 14) showed larger (infarct size 29.3 {+-} 7.8%) and more transmural (infarct severity 0.28 {+-} 0.10) infarctions, and reduced LV ejection fraction (35.4 {+-} 5.6%), but similar LV volume indexes, compared to patients without remodelling (n = 54) (infarct size 20.8 {+-} 14.4%, p < 0.05, infarct severity 0.40 {+-} 0.11, p < 0.001, ejection fraction 44.5 {+-} 9.2, p < 0.001). At stepwise multivariate regression analysis, infarct severity showed the best predictive value for predicting LV remodelling (F = 5.54, p < 0.05). Using the thresholds identified by receiver-operating characteristic curve analysis, infarct size and severity detected patients with remodelling with 75% accuracy and 95% negative predictive value. Infarct resorption (defined as the defect size difference between follow-up and baseline) was comparable between patients with (-4.4 {+-} 8.4%) and without remodelling (-6.8 {+-} 9.4%) (p = NS). Perfusion parameters assessed by gated SPECT in the subacute phase after successfully treated AMI correlate with changes in functional parameters at long-term follow-up. Infarct severity is more effective than infarct size, but both are helpful for predicting LV remodelling. (orig.)

  11. [Head to head comparison of dobutamine alone and combined with nitrate stress echocardiography and 99mTc-MIBI/18FDG myocardial SPECT image for diagnosis of viable myocardium in patients with severe left ventricular dysfunction].

    Science.gov (United States)

    Yang, Yue-jin; Yang, Wei-xian; Shi, Rong-fang; Hu, Feng-huan; You, Shi-jie; Tian, Yue-qin; He, Zuo-xiang; Wang, Yan-wu; Ye, Ling; Chen, Ji-lin; Gao, Run-lin; Chen, Zai-jia

    2005-04-01

    This study was sought to compare the sensitivity, specificity and accuracy of (1) dual isotope simultaneous acquisition single-photon emission computed tomography (DISA SPECT) myocardial image with (99m)Tc-sestamibi/(18)F-fluorodeoxyglucose ((99m)Tc-MIBI/(18)FDG); (2) low dose dobutamine alone and combined with Isosorbide Dinitrate (ISDN: Isoket) stress two dimensional echocardiography (2DE) to predict regional movement recovery after revascularization (CRV) in patients with old myocardial infarction (OMI) and severe left ventricular dysfunction. Twenty-six patients (mean age 51 +/- 8 years, male 25, female 1) with OMI and severe left ventricular dysfunction (mean left ventricular ejection fraction, LVEF (38.6% +/- 4.9%) underwent low dose dobutamine 10 microg x kg(-1) x min(-1) (Dob10 microg) and ISDN (286 +/- 31 microg/min) combined with Dob5 microg (ISDN-Dob 5 microg) 2DE and DISA SPECT within one week. In echocardiogram and DISA SPECT images: the left ventricle (LV) was divided into 16 segments. The semi-quantitative scoring system was used for both images. Myocardial viability was defined as an improvement of at least >or= 1 grade in at least two contiguous segments at rest 2DE after CRV. The viable segments detecting rate with stress 2DE and DISA SPECT were compared. Compared with the results of post-CRV, the sensitivity, specificity and accuracy of detecting viable segments of two methods were calculated. Among 272 abnormal segments in 26 patients, 156 (57.4%) segments showed contractile improvement after CRV. The viable segments detecting rate with DISA SPECT was 72.4% (134/254), which was significantly higher than the contractile improved rate after CRV (P 0.05). With DISA SPECT, the sensitivity, specificity and accuracy were 93.7%, 55% and 76.8%, respectively. Compared with DISA SPECT, Dob10 microg 2DE showed similar sensitivity (88.6%), specificity (64.2%) and the accuracy (77.9%). When ISDN combined with Dob5 microg, the sensitivity (91.4%), specificity

  12. Transient ischemic dilation for coronary artery disease in quantitative analysis of same-day sestamibi myocardial perfusion SPECT.

    Science.gov (United States)

    Xu, Yuan; Arsanjani, Reza; Clond, Morgan; Hyun, Mark; Lemley, Mark; Fish, Mathews; Germano, Guido; Berman, Daniel S; Slomka, Piotr J

    2012-06-01

    Transient ischemic dilation (TID) of the left ventricle in myocardial perfusion SPECT (MPS) has been shown to be a clinically useful marker of severe coronary artery disease (CAD). However, TID has not been evaluated for 99mTc-sestamibi rest/stress protocols (Mibi-Mibi). We aimed to develop normal limits and evaluate diagnostic power of TID ratio for Mibi-Mibi scans. TID ratios were automatically derived from static rest/stress MPS (TID) and gated rest/stress MPS from the end-diastolic phase (TID(ed)) in 547 patients who underwent Mibi-Mibi scans [215 patients with correlating coronary angiography and 332 patients with low likelihood (LLk) of CAD]. Scans were classified as severe (≥ 70% stenosis in proximal left anterior descending (pLAD) artery or left main (LM), or ≥ 90% in ≥ 2 vessels), mild to moderate (≥ 90% stenosis in 1 vessel or ≥ 70%-90% in ≥ 1 vessel except pLAD or LM), and normal (TID and 1.23 for TID(ed) as established in 259 LLk patients. Both ratios increased with disease severity (P TID increased from 2% in normal patients to >36% in patients with severe CAD. Similarly, when DI was used to classify disease severity, the average ratios showed significant increasing trend with DI increase (P TID also increased with increasing DI. The incidence of abnormal TID in the group with high perfusion scores significantly increased compared to the group with low perfusion scores (stress total perfusion deficit, TPD TID when added to mild to moderate perfusion abnormality (3% ≤ TPD TID(ed)/TID(es): 69% vs 64%, P = .08, while the accuracy remained consistent if abnormal TID was considered as a marker in addition to stress TPD. Similar results were obtained when DI was used for the definition of severe CAD (sensitivity: 76% vs 66%, P TID was combined with stress TPD). TID ratios obtained from gated or ungated Mibi-Mibi MPS and are useful markers of severe CAD.

  13. Improved accuracy of myocardial perfusion SPECT for detection of coronary artery disease by machine learning in a large population.

    Science.gov (United States)

    Arsanjani, Reza; Xu, Yuan; Dey, Damini; Vahistha, Vishal; Shalev, Aryeh; Nakanishi, Rine; Hayes, Sean; Fish, Mathews; Berman, Daniel; Germano, Guido; Slomka, Piotr J

    2013-08-01

    We aimed to improve the diagnostic accuracy of myocardial perfusion SPECT (MPS) by integrating clinical data and quantitative image features with machine learning (ML) algorithms. 1,181 rest (201)Tl/stress (99m)Tc-sestamibi dual-isotope MPS studies [713 consecutive cases with correlating invasive coronary angiography (ICA) and suspected coronary artery disease (CAD) and 468 with low likelihood (LLk) of CAD rest perfusion change, and transient ischemic dilatation were derived by automated perfusion quantification software and were combined with age, sex, and post-electrocardiogram CAD probability by a boosted ensemble ML algorithm (LogitBoost). The diagnostic accuracy of the model for prediction of obstructive CAD ≥70% was compared to standard prone/supine quantification and to visual analysis by two experienced readers utilizing all imaging, quantitative, and clinical data. Tenfold stratified cross-validation was performed. The diagnostic accuracy of ML (87.3% ± 2.1%) was similar to Expert 1 (86.0% ± 2.1%), but superior to combined supine/prone TPD (82.8% ± 2.2%) and Expert 2 (82.1% ± 2.2%) (P < .01). The receiver operator characteristic areas under curve for ML algorithm (0.94 ± 0.01) were higher than those for TPD and both visual readers (P < .001). The sensitivity of ML algorithm (78.9% ± 4.2%) was similar to TPD (75.6% ± 4.4%) and Expert 1 (76.3% ± 4.3%), but higher than that of Expert 2 (71.1% ± 4.6%), (P < .01). The specificity of ML algorithm (92.1% ± 2.2%) was similar to Expert 1 (91.4% ± 2.2%) and Expert 2 (88.3% ± 2.5%), but higher than TPD (86.8% ± 2.6%), (P < .01). ML significantly improves diagnostic performance of MPS by computational integration of quantitative perfusion and clinical data to the level rivaling expert analysis.

  14. Electrocardiographic-gated dual-isotope simultaneous acquisition SPECT using 18F-FDG and 99mTc-sestamibi to assess myocardial viability and function in a single study.

    Science.gov (United States)

    Matsunari, Ichiro; Kanayama, Sugako; Yoneyama, Tatsuya; Matsudaira, Masamichi; Nakajima, Kenichi; Taki, Junichi; Nekolla, Stephan G; Tonami, Norihisa; Hisada, Kinichi

    2005-02-01

    Dual-isotope simultaneous acquisition single-photon emission computed tomography (DISA SPECT) with 18F-fluorodeoxyglucose (FDG) and (99m)Tc-sestamibi appears attractive for the detection of viable myocardium because it permits simultaneous assessment of glucose utilisation and perfusion. Another potential benefit of this approach is that the measurement of left ventricular (LV) function may be possible by ECG gating. The aim of this study was to test the hypothesis that both myocardial viability and LV function can be assessed by a single ECG-gated 18F-FDG/(99m)Tc-sestamibi DISA SPECT study, based on comparison with 18F-FDG/13N-ammonia positron emission tomography (PET) and magnetic resonance imaging (MRI) as reference techniques. Thirty-three patients with prior myocardial infarction underwent ECG-gated 18F-FDG/(99m)Tc-sestamibi DISA SPECT and 18F-FDG/13N-ammonia PET on a single day. Of these, 25 patients also underwent cine-MRI to assess LV function. The LV myocardium was divided into nine regions, and each region was classified as viable or scar using a semiquantitative visual scoring system as well as quantitative analysis. The global and regional LV function measured by gated SPECT was compared with the results of MRI. There was good agreement in respect of viability (90-96%, kappa 0.74-0.85) between DISA SPECT and PET by either visual or quantitative analysis. Furthermore, although both global and regional LV function measured by gated SPECT agreed with those by MRI, (99m)Tc-sestamibi showed a closer correlation with MRI than did 18F-FDG. In conclusion, ECG-gated DISA SPECT provides information on myocardial viability, as well as global and regional LV function, similar to that obtained by PET and MRI.

  15. Prognostic significance of stress myocardial gated SPECT among Japanese patients referred for coronary angiography: A study of data from the J-ACCESS database

    Energy Technology Data Exchange (ETDEWEB)

    Momose, Mitsuru [Tokyo Women' s Medical University, Department of Radiology, Tokyo (Japan); Nakajima, Kenichi [Kanazawa University Hospital, Department of Nuclear Medicine, Kanazawa (Japan); Nishimura, Tsunehiko [Kyoto Prefectural University of Medicine, Department of Radiology, Graduate School of Medical Science, Kyoto (Japan)

    2009-08-15

    The J-ACCESS [Japanese investigation of prognosis based on gated single photon emission computed tomography (SPECT)] study found that quantitative gated myocardial SPECT (QGS) is valuable for predicting the prognosis of Japanese patients with known or suspected ischaemic heart disease. The present study evaluates the incremental prognostic value of myocardial perfusion imaging (MPI) with QGS among patients referred for coronary angiography (CAG). Among 4,031 Japanese patients registered at 117 hospitals for the J-ACCESS study, we selected 1,011 who underwent CAG within 3 months before or after MPI with QGS. Summed stress, rest and difference scores (SSS, SRS and SDS) were generated from myocardial perfusion images using a 20-segment scoring system. Myocardial ischaemia was judged visually. End-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) were determined by QGS. Numbers of diseased (> 75% stenosis) coronary vessels (CDV) were assessed by CAG. All patients were followed up for 3 years to determine cardiac events (CE) including cardiac death, non-fatal myocardial infarction and severe heart failure. Univariate and multivariate analyses of prognostic ability included age, cardiac risk factors (hypertension, hyperlipidaemia, diabetes mellitus and prior myocardial infarction), angiographic findings and the QGS parameters as independent variables. Cardiac events occurred more frequently with increasing numbers of coronary vessel lesions (p=0.0016). Cox univariate analysis revealed that diabetes, CDV, SSS, SDS, EDV, ESV and EF were significant predictors (Wald {chi}{sup 2}=5.99, 12.9, 8.39, 9.11, 35.5, 42.1 and 31.1, respectively), whereas multivariate analysis selected only ESV and SDS as significant predictors (Wald {chi}{sup 2}=36.4, 8.4; p = 0.0038, p < 0.001). MPI with QGS, especially with gated functional data, has incremental prognostic value in addition to angiographic findings. MPI with QGS findings predominantly contribute to the

  16. Detection and quantification of acute reperfused myocardial infarction in rabbits using DISA-SPECT/CT and 3.0T cardiac MRI.

    Science.gov (United States)

    Feng, Yuanbo; Cona, Marlein Miranda; Vunckx, Kathleen; Li, Yue; Chen, Feng; Nuyts, Johan; Gheysens, Olivier; Zhou, Lin; Xie, Yi; Oyen, Raymond; Ni, Yicheng

    2013-10-09

    Necrosis avid tracer (123)I-hypericin ((123)I-HYP) enables hot-spot imaging on acute myocardial infarction (MI). We explored dual-isotope simultaneous acquisition single photon emission computed tomography/computed tomography (DISA-SPECT/CT) by using (123)I-HYP and standard (99m)Tc-sestamibi ((99m)Tc-MIBI), in comparison with cardiac magnetic resonance imaging (cMRI), autoradiography (AutoRx) and histomorphometry. Acute MI was induced by 90-min coronary artery occlusion and 24-h reperfusion in 9 rabbits. They were scanned with cMRI at 3.0T, followed by intravenous injections of (123)I-HYP, and 8h later, of (99m)Tc-MIBI. Then, they were imaged with DISA-SPECT/CT for detection and localization of MI. The excised heart was sectioned for AutoRx, triphenyltetrazolium chloride (TTC) histochemistry, and haematoxylin-eosin (HE) staining. DISA-SPECT/CT and cMRI were co-registered, and MI was compared between different modalities and techniques for correlation with ex vivo findings. Tracer/contrast uptakes were quantified on polar maps. One way-ANOVA and Bonferroni's tests were used for comparison of multiple techniques. Linear regression and Bland-Altman analysis were used to compare measurements of MI. MI volumes were not significantly different as by (99m)Tc-MIBI-SPECT, (123)I-HYP-SPECT, cMRI and TTC (38.94 ± 13.97%, 37.76 ± 13.16%, 35.19 ± 12.53% and 33.26 ± 10.65%; p > 0.05). The MI areas were 41.13 ± 18.70%, 40.19 ± 18.45%, 38.23 ± 16.86%, 36.83 ± 16.70%, 36.16 ± 16.15% and 35.03 ± 14.75% on (99m)Tc-MIBI-SPECT, (123)I-HYP-SPECT, cMRI, AutoRx, TTC and HE. There was no significant differences between each of two techniques (p = 0.9). Tracer/contrast uptakes were well correlated ((123)I-HYP vs (99m)Tc-MIBI r(2) = 0.66; (123)I-HYP vs cMRI r(2) = 0.63; (99m)Tc-MIBI vs cMRI r(2) = 0.64). Infarct/normal myocardium activity ratio was 40/1 and 23/1 by AutoRx and γ-counting. (123)I-HYP has shown pronounced necrosis-avidity, which proves complementary for imaging MI

  17. The effect of CT-based attenuation correction on the automatic perfusion score of myocardial perfusion imaging using a dedicated cardiac solid-state CZT SPECT/CT.

    Science.gov (United States)

    Kennedy, John A; Brodov, Yafim; Weinstein, Adam L; Israel, Ora; Frenkel, Alex

    2017-05-01

    Data regarding cardiac cadmium-zinc-telluride (CZT)-specific augmented databases and their impact on CT-based attenuation correction (AC) perfusion scores in myocardial perfusion imaging (MPI) were obtained on a multiple-pinhole CZT SPECT/CT. Summed stress (SSS) and rest scores (SRS) were measured using automated software in three independent patient groups: group 1 (n = 80) underwent MPI on both CZT and conventional sodium iodide (NaI) devices, group 2 (n = 80) with low coronary artery disease likelihood and normal MPI provided reference CZT databases; and group 3 (n = 152) served to compare AC and non-AC (NAC) scores on CZT. Group 1 CZT and NaI scores gave a significant 1:1 linear correlation for CZT scores referenced to the custom database vs NaI scores referenced to the default database, but these were not concordant when CZT scores were referenced to the default database. AC significantly decreased average SSS and SRS in men vs NAC, 4.29 ± 6.30 vs 5.37 ± 7.26 (P < 0.001) and 2.37 ± 4.72 vs 3.13 ± 5.85 (P < 0.001), but not in women, 2.28 ± 3.42 vs 2.28 ± 3.08 (p NS) and 0.46 ± 1.51 vs 0.61 ± 1.86, (p NS), respectively. Specifically designed databases for solid-state CZT cardiac SPECT provide accurate quantitation of perfusion scores concordant with those previously validated for conventional SPECT. AC and NAC CZT scores differed significantly, especially in men.

  18. The importance of a correct positioning of the heart using IQ-SPECT system with multifocal collimators in myocardial perfusion imaging: a phantom study.

    Science.gov (United States)

    Caobelli, Federico; Ren Kaiser, Stefano; Thackeray, James Thomas; Bengel, Frank Michael; Chieregato, Matteo; Soffientini, Alberto; Pizzocaro, Claudio; Savelli, Giordano; Guerra, Ugo Paolo; Galelli, Marco; Zoccarato, Orazio

    2015-02-01

    We have recently validated a quarter-time protocol in Myocardial Perfusion Imaging named IQ-SPECT, whose basic principle is to implement a multifocal collimator; However, in clinical practice, it may sometimes be difficult to center the heart in the region of highest magnification of the multifocal collimators (the so-called sweet spot). We therefore aimed to evaluate whether a heart mispositioning may affect results in MPI. We simulated a rest study with an anthropomorphic phantom with an in vivo distribution of 400 MBq [(99m)Tc]tetrofosmin, with and without a transmural defect (TD). For each set of images, we performed 5 acquisitions, one with a correct centering and with other 4 degrees of mispositioning. Raw data and reconstructed images were evaluated qualitatively and quantitatively, including no corrections, correction for attenuation, for scatter or for both. We assessed polar plot uniformity, LV wall thickness, and TD and cavity contrast. Images obtained either with a correct heart centering or with mild misposition showed no differences, both qualitatively and quantitatively. Those obtained with major mispositioning differed in uniformity and TD contrast depending on correction parameters. This is the first study investigating how a heart mispositioning can affect diagnostic accuracy with IQ-SPECT system. Mild-to-moderate mispositioning (≤2.5 cm) is unlikely to significantly affect results.

  19. Correlation of quantitative Tc-99m sestamibi myocardial perfusion SPECT and left ventricular ejection fraction in patients with prior myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Kiat, H.; Tecson, J.; Hutton, A.; Eggins, P.; Fenton, S. [Sydney Cardiology Group, Sydney NSW (Australia)

    1998-02-01

    Full text: Rest Tc-99m sestamibi (MIBI) SPECT is frequently used to assess infarct size. To validate the use of quantitative (Q) rest MIBI SPECT for this assessment, we examined the relationship of Q rest MIBI to rest Q MIBI LVEF. We studied 21 patients with prior Ml, patients with cardiomyopathy were excluded. Q rest MIBI analysis employed a previously validated and commercially available automated Q program (CEqual) involving generation of maximum count circumferential profiles using spherical and cylindrical search of the myocardium and comparison to previously developed normal limits. Q defect extent (EXT) was expressed as % myocardium and Q defect severity (SEV) was calculated for the total myocardium by summing the products of number of pixels falling below the normal mean X SDs below the normal mean. Q LVEF was acquired using previously validated and commercially available automated gated SPECT program from Cedars-Sinai Medical Centre. Defect EXT and SEV by Q rest MIBI SPECT correlate well with rest LVEF over a wide range of LV function 1 fig.

  20. Adaptive Bayesian Iterative Transmission Reconstruction for Attenuation Correction in Myocardial Perfusion Imaging with SPECT/Slow-Rotation Low-Output CT Systems

    Directory of Open Access Journals (Sweden)

    Ji Chen

    2007-01-01

    Full Text Available Objectives. SPECT/slow-rotation low-output CT systems can produce streak artifacts in filtered backprojection (FBP attenuation maps, impacting attenuation correction (AC in myocardial perfusion imaging. This paper presents an adaptive Bayesian iterative transmission reconstruction (ABITR algorithm for more accurate AC. Methods. In each iteration, ABITR calculated a three-dimensional prior containing the pixels with attenuation coefficients similar to water, then used it to encourage these pixels to the water value. ABITR was tested with a cardiac phantom and 4 normal patients acquired by a GE Millennium VG/Hawkeye system. Results. FBP AC and ABITR AC produced similar phantom results. For the patients, streak artifacts were observed in the FBP and ordered-subsets expectation-maximization (OSEM maps but not in the ABITR maps, and ABITR AC produced more uniform images than FBP AC and OSEM AC. Conclusion. ABITR can improve the quality of the attenuation map, producing more uniform images for normal studies.

  1. SPECT imaging of myocarditis

    Energy Technology Data Exchange (ETDEWEB)

    Shulkin, B.L.; Wahl, R.L.

    1987-11-01

    Gallium-67 citrate has been useful in providing scintigraphic evidence for pericarditis and myocarditis. However, the differentiation between pericardial and myocardial localization is difficult with planar images alone. SPECT can be valuable in making these distinctions, and a case of myocarditis is presented in which uptake of Gallium is shown to lie within the heart, correlating with the histologic proof.

  2. IQ SPECT allows a significant reduction in administered dose and acquisition time for myocardial perfusion imaging: evidence from a phantom study.

    Science.gov (United States)

    Caobelli, Federico; Kaiser, Stefano Ren; Thackeray, James T; Bengel, Frank M; Chieregato, Matteo; Soffientini, Alberto; Pizzocaro, Claudio; Savelli, Giordano; Galelli, Marco; Guerra, Ugo Paolo

    2014-12-01

    We recently demonstrated in a clinical trial the ability of a new protocol, IQ SPECT, to acquire myocardial perfusion imaging (MPI) studies in a quarter of the time (12 s/view) of the standard protocol, with preserved diagnostic accuracy. We now aim to establish the lower limit of radioactivity that can be administered to patients and the minimum acquisition time in SPECT MPI using an IQ SPECT protocol, while preserving diagnostic accuracy. An anthropomorphic cardiac phantom was used to acquire clinical rest scans with a simulated in vivo distribution of (99m)Tc-tetrofosmin at full dose (740 MBq) and at doses equal to 50%, 25%, and 18%. For each dose, 2 sets of images were acquired, with and without a transmural defect (TD). Variable acquisition times were also used for each dose. We analyzed raw data and reconstructed images, including no correction and correction for attenuation (AC), for scatter (SC), or for both (ACSC). Images were evaluated qualitatively and quantitatively in order to assess left ventricle (LV) wall thickness (full width at half maximum of the medial sections), TD, and cavity contrast in the LV wall. Data were compared across different acquisition times within the same dose and across doses with the same acquisition time. Images were visually scored as very-good quality except those acquired with 4 s/view or less at 100% dose and 6 s/view or less with 50%, 25%, or 18% dose, due to false-positive defects. LV wall thickness was not significantly different among all acquisitions. Cavity contrast remained unchanged within the same dose for all images and tended to be higher in AC and ACSC images. TD contrast remained unchanged within the same dose for all images. In SC and no-correction images, contrast was constant for all doses. AC images had significantly higher TD contrast values, and ACSC images showed a drop in TD contrast for a 50% dose. IQ SPECT effectively preserved both image quality and quantitative measurements with reduced acquisition

  3. Effects of Potassium-Channel Opener on Thallium-201 Kinetics: In-vitro Study in Rat Myocyte Preparations and In-vivo Mice Biodistribution Study

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae Tae; Kim, Eun Ji; Ahn, Byeong Cheol; Son, Kang Kyun; Lee, Kyu Bo [Kyungpook National University School of Medicine, Taegu (Korea, Republic of); Ha, Jeoung Hee [Youngnam University Medical School, Taegu (Korea, Republic of); Kim, Chun Ki [Mt. Sinai School of Medicine, New York (United States)

    1996-10-15

    -201 myocardial images, due to decreasing thallium accumulation and enhancing washout from myocardium.

  4. The significance of post-stress decrease in left ventricular ejection fraction in patients undergoing regadenoson stress gated SPECT myocardial perfusion imaging.

    Science.gov (United States)

    Gomez, Javier; Golzar, Yasmeen; Fughhi, Ibtihaj; Olusanya, Adebayo; Doukky, Rami

    2017-02-08

    The significance of post-stress decrease in left ventricular ejection fraction (LVEF) with regadenoson stress gated SPECT (GSPECT) myocardial perfusion imaging (MPI) has not been studied. Consecutive patients who underwent rest/regadenoson stress GSPECT-MPI followed by coronary angiography within 6 months were analyzed. Change in LVEF by GSPECT-MPI was calculated as stress LVEF minus rest LVEF; a significant decrease was tested at 5% and 10% thresholds. In a diagnostic cohort of 793 subjects, LVEF change was not predictive of severe/extensive coronary artery disease (area under the curve, 0.50; 95% confidence interval, 0.44-0.57; P = 0.946). There was no significant difference in the rates of severe/extensive coronary artery disease in patients with or without a decrease in LVEF, irrespective of MPI findings. In an outcome cohort of the 929 subjects followed for 30 ± 16 months, post-regadenoson stress decrease in LVEF was not associated with increased risk of the composite endpoint of cardiac death or myocardial infarction or in the risk of coronary revascularization. In patients selected to undergo coronary angiography following regadenoson stress GSPECT-MPI, a decrease in LVEF after regadenoson stress is not predictive of severe/extensive CAD or adverse clinical outcomes, irrespective of MPI findings.

  5. Prognostic value of myocardial perfusion single photon emission computed tomography for major adverse cardiac cerebrovascular and renal events in patients with chronic kidney disease: results from first year of follow-up of the Gunma-CKD SPECT multicenter study

    Energy Technology Data Exchange (ETDEWEB)

    Kasama, Shu [Gunma University Graduate School of Medicine, Department of Medicine and Biological Science (Cardiovascular Medicine), Maebashi, Gunma (Japan); Cardiovascular Hospital of Central Japan (Kitakanto Cardiovascular Hospital), Department of Cardiovascular Medicine, Gunma (Japan); Toyama, Takuji [Department of Cardiovascular Medicine, Gunma Prefectural Cardiovascular Center, Maebashi (Japan); Sato, Makito [Gunma University Graduate School of Medicine, Department of Medicine and Biological Science (Cardiovascular Medicine), Maebashi, Gunma (Japan); Tatebayashi Kosei Hospital, Department of Internal Medicine, Gunma (Japan); Sano, Hirokazu [Gunma University Graduate School of Medicine, Department of Medicine and Biological Science (Cardiovascular Medicine), Maebashi, Gunma (Japan); Isesaki Municipal Hospital, Department of Cardiovascular Medicine, Isesaki (Japan); Ueda, Tetsuya [Fujioka General Hospital, Division of Cardiology, Fujioka (Japan); Sasaki, Toyoshi [Takasaki General Medical Center, Division of Cardiology, Takasaki (Japan); Nakahara, Takehiro; Kurabayashi, Masahiko [Gunma University Graduate School of Medicine, Department of Medicine and Biological Science (Cardiovascular Medicine), Maebashi, Gunma (Japan); Higuchi, Tetsuya; Tsushima, Yoshito [Gunma University Graduate School of Medicine, Department of Diagnostic Radiology and Nuclear Medicine, Maebashi (Japan)

    2016-02-15

    Patients with chronic kidney disease (CKD) have an increased risk of adverse cardio-cerebrovascular events. We examined whether stress myocardial perfusion single photon emission computed tomography (SPECT) provides reliable prognostic markers for these patients. In this multicenter, prospective cohort trial from the Gunma-CKD SPECT study protocol, patients with CKD [estimated glomerular filtration rate (eGFR) < 60 min/ml per 1.73 m{sup 2}] undergoing stress {sup 99m}Tc-tetrofosmin SPECT for suspected or possible ischemic heart disease were initially followed for 1 year, with the following study endpoints: primary, the occurrence of cardiac deaths (CDs), and secondary, major adverse cardiac, cerebrovascular, and renal events (MACCREs). The summed stress score (SSS), summed rest score, and summed difference score (SDS) were estimated with the standard 17-segment, 5-point scoring model. Left ventricular end-diastolic volume, end-systolic volume (ESV), and ejection fraction were measured using electrocardiogram-gated SPECT. During the first year of follow-up, 69 of 299 patients experienced MACCREs (CD, n = 7; non-fatal myocardial infarction, n = 3; hospitalization for heart failure, n = 13; cerebrovascular accident, n = 1; need for revascularization, n = 38; and renal failure, i.e., hemodialysis initiation, n = 7). ESV and SSS were associated with CDs (p < 0.05), and eGFR and SDS were associated with MACCREs (p < 0.05), in multivariate logistic analysis. Patients with high ESV and high SSS had a significantly higher CD rate during the first year than the other CKD patient subgroups (p < 0.05). Patients with low eGFR and high SDS had a significantly higher MACCRE rate than the other subgroups (p < 0.05). Myocardial perfusion SPECT can provide reliable prognostic markers for patients with CKD. (orig.)

  6. Reproducibility of area at risk assessment in acute myocardial infarction by T1- and T2-mapping sequences in cardiac magnetic resonance imaging in comparison to Tc99m-sestamibi SPECT.

    Science.gov (United States)

    Langhans, Birgit; Nadjiri, Jonathan; Jähnichen, Christin; Kastrati, Adnan; Martinoff, Stefan; Hadamitzky, Martin

    2014-10-01

    Area at risk (AAR) is an important parameter for the assessment of the salvage area after revascularization in acute myocardial infarction (AMI). By combining AAR assessment by T2-weighted imaging and scar quantification by late gadolinium enhancement imaging cardiovascular magnetic resonance (CMR) offers a promising alternative to the "classical" modality of Tc99m-sestamibi single photon emission tomography (SPECT). Current T2 weighted sequences for edema imaging in CMR are limited by low contrast to noise ratios and motion artifacts. During the last years novel CMR imaging techniques for quantification of acute myocardial injury, particularly the T1-mapping and T2-mapping, have attracted rising attention. But no direct comparison between the different sequences in the setting of AMI or a validation against SPECT has been reported so far. We analyzed 14 patients undergoing primary coronary revascularization in AMI in whom both a pre-intervention Tc99m-sestamibi-SPECT and CMR imaging at a median of 3.4 (interquartile range 3.3-3.6) days after the acute event were performed. Size of AAR was measured by three different non-contrast CMR techniques on corresponding short axis slices: T2-weighted, fat-suppressed turbospin echo sequence (TSE), T2-mapping from T2-prepared balanced steady state free precession sequences (T2-MAP) and T1-mapping from modified look locker inversion recovery (MOLLI) sequences. For each CMR sequence, the AAR was quantified by appropriate methods (absolute values for mapping sequences, comparison with remote myocardium for other sequences) and correlated with Tc99m-sestamibi-SPECT. All measurements were performed on a 1.5 Tesla scanner. The size of the AAR assessed by CMR was 28.7 ± 20.9 % of left ventricular myocardial volume (%LV) for TSE, 45.8 ± 16.6 %LV for T2-MAP, and 40.1 ± 14.4 %LV for MOLLI. AAR assessed by SPECT measured 41.6 ± 20.7 %LV. Correlation analysis revealed best correlation with SPECT for T2-MAP at a T2-threshold of 60 ms

  7. Diagnosis of myocardial involvement in patients with systemic myopathies with 15-(p-[I-123]iodophenyl) pentadecanoic acid (IPPA) SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kropp, J.; Briele, B.; Smekal, A.V.; Hotze, A.L.; Biersack, H.J.; Koehler, U.; Zierz, St. [Bonn Univ. (Germany); Knapp, F.F. [Oak Ridge National Lab., TN (United States)

    1992-03-01

    Involvement of the myocardium in non-infectious myopathies presents in most cases as systolic dysfunction or a disturbed cardiac rhythm. We are interested in exploring how often cardiac involvement can be evaluated with various diagnostic techniques in patients with proven myopathy. We investigated 41 patients with myopathies of various etiology, including mitochondrial and congenital myopathies, Curshmann-Steinert disease, muscular dystrophy, and others. Myopathy was proven by muscular biopsy usually from the bicep. Fatty acid imaging was performed with 15-(p-[I-123]iodophenyl)pentadecanoic acid (IP-PA) and sequential SPECT-scintigraphy with a 180 deg. rotation starting at the 45 deg. RAO position. 190 MBq were injected at the maximal stage of a submaximal exercise. Filtered backprojection and reorientation of the slices were achieved by standard techniques. The quantitative comparison of the oblique slices (bulls-eye technique) of the SPECT-studies revealed turnover-rates as a qualitative measure of {beta}-oxidation. Serum levels of lactate (L), pyruvate (P), glucose (G) and triglycerides (TG) were measured at rest and stress. Ventricular function was investigated by radionuclide ventriculography (MUGA) at rest and under stress with Tc-99m labeled red blood cells. In addition, ECG, 24 hour-ECG, and echocardiography were also performed with standard techniques.

  8. Diagnosis of myocardial involvement in patients with systemic myopathies with 15-(p-(I-123)iodophenyl) pentadecanoic acid (IPPA) SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kropp, J.; Briele, B.; Smekal, A.V.; Hotze, A.L.; Biersack, H.J.; Koehler, U.; Zierz, St. (Bonn Univ. (Germany)); Knapp, F.F. (Oak Ridge National Lab., TN (United States))

    1992-01-01

    Involvement of the myocardium in non-infectious myopathies presents in most cases as systolic dysfunction or a disturbed cardiac rhythm. We are interested in exploring how often cardiac involvement can be evaluated with various diagnostic techniques in patients with proven myopathy. We investigated 41 patients with myopathies of various etiology, including mitochondrial and congenital myopathies, Curshmann-Steinert disease, muscular dystrophy, and others. Myopathy was proven by muscular biopsy usually from the bicep. Fatty acid imaging was performed with 15-(p-(I-123)iodophenyl)pentadecanoic acid (IP-PA) and sequential SPECT-scintigraphy with a 180 deg. rotation starting at the 45 deg. RAO position. 190 MBq were injected at the maximal stage of a submaximal exercise. Filtered backprojection and reorientation of the slices were achieved by standard techniques. The quantitative comparison of the oblique slices (bulls-eye technique) of the SPECT-studies revealed turnover-rates as a qualitative measure of {beta}-oxidation. Serum levels of lactate (L), pyruvate (P), glucose (G) and triglycerides (TG) were measured at rest and stress. Ventricular function was investigated by radionuclide ventriculography (MUGA) at rest and under stress with Tc-99m labeled red blood cells. In addition, ECG, 24 hour-ECG, and echocardiography were also performed with standard techniques.

  9. Thallium-201 uptake in a benign thymoma

    Energy Technology Data Exchange (ETDEWEB)

    Campeau, R.J.; Ey, E.H.; Varma, D.G.

    1986-07-01

    A 68-year-old woman was admitted with atypical angina. A chest radiograph showed an anterior mediastinal mass that was confirmed on CT. The mass was relatively avascular and separate from the heart and great vessels. She underwent stress thallium testing that demonstrated no exercise-induced ischemia; however, an abnormal focus of thallium activity was present in the anterior mediastinum on stress and redistribution images. Cardiac catheterization demonstrated a normal left ventriculogram, coronary arteries and thoracic aorta. Subsequent surgery and pathologic examination revealed the mass to be a benign thymoma arising in the right lobe of the thymus gland.

  10. Use of {sup 99m}Tc-sestamibi gated SPECT to assess the influence of anterograde flow before primary coronary angioplasty on tissue salvage and functional recovery in acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Leoncini, Mario; Bellandi, Francesco; Maioli, Mauro; Toso, Anna; Dabizzi, Roberto Piero [Misericordia e Dolce Hospital, Division of Cardiology, Prato (Italy); Sciagra, Roberto; Pupi, Alberto [University of Florence, Department of Clinical Physiopathology, Nuclear Medicine Unit, Florence (Italy); Sestini, Stelvio; Coppola, Angela; Mennuti, Alberto [Misericordia e Dolce Hospital, Nuclear Medicine Unit, Prato (Italy)

    2004-10-01

    Preserved thrombolysis in myocardial infarction (TIMI) flow before percutaneous coronary intervention (PCI) in acute myocardial infarction is related to improved outcome. Gated single-photon emission computed tomography (SPECT) allows the simultaneous assessment of left ventricular perfusion and function. We evaluated the initial risk area and subsequent evolution of perfusion and function according to TIMI flow before successful primary PCI. In 36 patients, treated with abciximab, primary PCI and stenting, {sup 99m}Tc-sestamibi was injected before PCI and gated SPECT acquired thereafter. Gated SPECT was repeated 7 and 30 days later. Perfusion defect, wall motion score index, left ventricular ejection fraction and volumes were examined. Before PCI, 14 patients (group A) showed TIMI flow 2-3 and 22 (group B) TIMI flow 0-1, but no differences in clinical variables, initial risk area, wall motion score, ejection fraction or volumes. Perfusion defect was smaller in group A at 7 (9%{+-}11% vs 19%{+-}14%, p<0.02) and 30 days (7%{+-}7% vs 16%{+-}12%, p<0.02) and the salvage index was higher at 30 days (77%{+-}22% vs 55%{+-}28%, p<0.02). Wall motion score was lower in group A at 30 days (p<0.05). Ejection fraction significantly improved in both groups at 7 and 30 days. End-diastolic volume showed a trend towards a reduction in group A, whilst it was significantly increased in group B. Conversely, end-systolic volume was significantly decreased in group A but remained unchanged in group B. In the setting of optimal myocardial reperfusion for myocardial infarction, preserved TIMI flow before PCI does not limit the initial risk area but it does improve myocardial salvage and functional recovery. (orig.)

  11. Myocardial perfusion SPECT in stable angina;Place de la scintigraphie myocardique dans l'angor stable

    Energy Technology Data Exchange (ETDEWEB)

    Jau, P.; Jacob, T. [HP Clairval, Service de medecine nucleaire, 13 - Marseille (France); Lecorff, G.; Bouvier, J.L.; Novella, P.; Bechet, V.; Pelet, V. [HP Clairval, Service de cardiologie, 13 - Marseille (France)

    2010-03-15

    We study the precise contribution of myocardial scintigraphy in the therapeutic management of stable coronary artery disease. Until recently, treatment was focused on revascularization, often by coronary angioplasty.Recent studies have challenged this practice by showing the absence of superiority of angioplasty compared to optimal medical therapy.The problem now is to define for each stable coronary artery disease, and individually, the best of both treatment options. In this spirit, the functional approach to coronary artery disease by myocardial perfusion scintigraphy is most interesting.The diagnostic performance, including sensitivity and negative predictive value, and the prognostic value of the technique are clearly established. Recent studies show that a therapeutic decision based on a functional approach to the patient is valid.We need to know this development in cardiology for best position in the multidisciplinary discussions, myocardial scintigraphy as a functional approach to stable coronary artery disease. (N.C.)

  12. Wide beam reconstruction "quarter-time" gated myocardial perfusion SPECT functional imaging: a comparison to "full-time" ordered subset expectation maximum.

    Science.gov (United States)

    DePuey, E Gordon; Bommireddipalli, Srinivas; Clark, John; Thompson, Linda; Srour, Yossi

    2009-01-01

    Previously we reported that compared to iterative reconstruction with ordered subset expectation maximum (OSEM), wide beam reconstruction (WBR), which incorporates resolution recovery and controls noise during reconstruction without applying a post-processing filter, allows half-time SPECT acquisition with preserved diagnostic quality. We now postulate that with further Poisson noise treatment, quarter-time acquisition is possible. The half-time WBR algorithm was optimized for quarter-time acquisition based upon anthropomorphic cardiac phantom data and a pilot group of 48 patients (pts). Then using the modified algorithm, 209 pts (91 men, 118 women, mean chest circumference = 40 in) were imaged at rest (R) and stress (S) (9/32 mCi (99m)Tc-sestamibi) full-time with OSEM, and again quarter-time with the modified WBR algorithm. The 180 degrees , 64-stop, full-time single-day rest (R) (25 second-per-stop, sps) and 8-frame per cardiac cycle post-stress (S) (20 sps) gated SPECT, and then quarter-time R (6 sps) and post-S (4 sps) gated SPECT were acquired. Blinded observers graded scan quality (1 = poor to 5 = excellent) based on myocardial uniformity, endocardial/epicardial edge definition, and background noise. Perfusion defects were scored using a 17-segment model. Using three commercially available software methods, end-diastolic volume (EDV), end-systolic volume (ESV), and left ventricular ejection fraction (LVEF) were calculated. For the 209 prospective pts, mean image quality for R full-time OSEM and quarter-time WBR were similar (3.5 +/- 0.9 vs 3.6 +/- 0.7, p NS). For S, quarter-time WBR quality was superior to full-time OSEM (4.3 +/- 0.7 vs 3.9 +/- 0.7) (P = 1.78 x 10(-17)). In 35 pts with chest circumferences >44 inches a longer, 10 sps WBR acquisition improved resting image quality. Of 48 pts with abnormal scans (SSSs > 2 by OSEM) mean summed stress scores, summed rest scores, and summed difference scores were not significantly different with quarter-time WBR

  13. SPECT imaging of myocardial infarction using {sup 99m}Tc-labeled C2A domain of synaptotagmin I in a porcine ischemia-reperfusion model

    Energy Technology Data Exchange (ETDEWEB)

    Fang Wei [Department of Nuclear Medicine, Cardiovascular Institute and Fu Wai Hospital, Chinese Academy of Medical Sciences, Beijing 100037 (China); Wang Feng [Nuclear Medicine Department, Nanjing First Hospital Affiliated to Nanjing Medical University, Nanjing 210006 (China); Ji Shundong [Jiangsu Institute of Hematology, 1st Hospital of Suzhou University, Suzhou 215006 (China); Zhu Xiaoguang [Department of Biophysics, Medical College of Wisconsin, Milwaukee, Wisconsin, WI 53226 (United States); Meier, Heidi T. [Clinical Veterinarian and Radiology Research, Clement J. Zablocki Veterans Affairs Medical Center, Milwaukee, Wisconsin, WI 53295 (United States); Hellman, Robert S. [Department of Radiology, Medical College of Wisconsin, Milwaukee, Wisconsin, WI 53226 (United States); Brindle, Kevin M. [MRC Laboratory of Molecular Biology, Cambridge CB2 2QH (United Kingdom); Davletov, Bazbek [Department of Biochemistry, University of Cambridge, Cambridge CB2 1GA (United Kingdom); Zhao Ming [Department of Biophysics, Medical College of Wisconsin, Milwaukee, Wisconsin, WI 53226 (United States)], E-mail: mzhao@mcw.edu

    2007-11-15

    Introduction: The C2A domain of synaptotagmin I recognizes necrotic and apoptotic cells by binding to exposed anionic phospholipids. The goal is to explore the potential imaging utility of {sup 99m}Tc-labeled C2A in the detection of acute cardiac cell death in a porcine model that resembles human cardiovascular physiology. Methods: Ischemia (20-25 min) was induced in pigs (M/F, 20-25 kg) using balloon angioplasty. {sup 99m}Tc-C2A-GST (n=7) or {sup 99m}Tc-BSA (n=2) was injected intravenously 1-2 h after reperfusion. Noninfarct animals were injected with {sup 99m}Tc-C2A-GST (n=4). SPECT images were acquired at 3 and 6 h postinjection. Cardiac tissues were analyzed to confirm the presence of cell death. Results: Focal uptake was detected in five out of seven subjects at 3 h and in all infarct subjects at 6 h postinjection but not in infarct animals injected with {sup 99m}Tc-BSA or in noninfarct animals with {sup 99m}Tc-C2A-GST. Gamma counting of infarct versus normal myocardium yielded a 10.2{+-}5.7-fold elevation in absolute radioactivity, with histologically confirmed infarction. Conclusions: We present data on imaging myocardial cell death in the acute phase of infarction in pigs. C2A holds promise and warrants further development as an infarct-avid molecular probe.

  14. Effect of caffeine on SPECT myocardial perfusion imaging during regadenoson pharmacologic stress: rationale and design of a prospective, randomized, multicenter study.

    Science.gov (United States)

    Tejani, Furqan H; Thompson, Randall C; Iskandrian, Ami E; McNutt, Bruce E; Franks, Billy

    2011-02-01

    Caffeine attenuates the coronary hyperemic response to adenosine by competitive A₂(A) receptor blockade. This study aims to determine whether oral caffeine administration compromises diagnostic accuracy in patients undergoing vasodilator stress myocardial perfusion imaging (MPI) with regadenoson, a selective adenosine A(2A) agonist. This multicenter, randomized, double-blind, placebo-controlled, parallel-group study includes patients with suspected coronary artery disease who regularly consume caffeine. Each participant undergoes three SPECT MPI studies: a rest study on day 1 (MPI-1); a regadenoson stress study on day 3 (MPI-2), and a regadenoson stress study on day 5 with double-blind administration of oral caffeine 200 or 400 mg or placebo capsules (MPI-3; n = 90 per arm). Only participants with ≥ 1 reversible defect on the second MPI study undergo the subsequent stress MPI test. The primary endpoint is the difference in the number of reversible defects on the two stress tests using a 17-segment model. Pharmacokinetic/pharmacodynamic analyses will evaluate the effect of caffeine on the regadenoson exposure-response relationship. Safety will also be assessed. The results of this study will show whether the consumption of caffeine equivalent to 2-4 cups of coffee prior to an MPI study with regadenoson affects the diagnostic validity of stress testing (ClinicalTrials.gov number, NCT00826280).

  15. Low-dose single acquisition rest {sup 99m}Tc/stress {sup 201}Tl myocardial perfusion SPECT protocol: phantom studies and clinical validation

    Energy Technology Data Exchange (ETDEWEB)

    Dey, Thomas [RWTH Aachen University, Institute of Imaging and Computer Vision, Aachen (Germany); Backus, Barbra E.; Romijn, R.Leo [St. Antonius Hospital, Department of Nuclear Medicine, Nieuwegein (Netherlands); Wieczorek, Herfried [Philips Research, Eindhoven (Netherlands); Verzijlbergen, J.F. [St. Antonius Hospital, Department of Nuclear Medicine, Nieuwegein (Netherlands); Erasmus Medical Center, Department of Nuclear Medicine, Rotterdam (Netherlands)

    2014-03-15

    We developed and tested a single acquisition rest {sup 99m}Tc-sestamibi/stress {sup 201}Tl dual isotope protocol (SDI) with the intention of improving the clinical workflow and patient comfort of myocardial perfusion single photon emission computed tomography (SPECT). The technical feasibility of SDI was evaluated by a series of anthropomorphic phantom studies on a standard SPECT camera. The attenuation map was created by a moving transmission line source. Iterative reconstruction including attenuation correction, resolution recovery and Monte Carlo simulation of scatter was used for simultaneous reconstruction of dual tracer distribution. For clinical evaluation, patient studies were compared to stress {sup 99m}Tc and rest {sup 99m}Tc reference images acquired in a 2-day protocol. Clinical follow-up examinations like coronary angiography (CAG) and fractional flow reserve (FFR) were included in the assessment if available. Phantom studies demonstrated the technical feasibility of SDI. Artificial lesions inserted in the phantom mimicking ischaemia could be clearly identified. In 51/53 patients, the image quality was adequate for clinical evaluation. For the remaining two obese patients with body mass index > 32 the injected {sup 201}Tl dose of 74 MBq was insufficient for clinical assessment. In answer to this the {sup 201}Tl dose was adapted for obese patients in the rest of the study. In 31 patients, SDI and {sup 99m}Tc reference images resulted in equivalent clinical assessment. Significant differences were found in 20 patients. In 18 of these 20 patients additional examinations were available. In 15 patients the diagnosis based on the SDI images was confirmed by the results of CAG or FFR. In these patients the SDI images were more accurate than the {sup 99m}Tc reference study. In three patients minor ischaemic lesions were detected by SDI but were not confirmed by CAG. In one of these cases this was probably caused by pronounced apical thinning. For two patients

  16. The current status of SPECT or SPECT/CT in South Korea

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Ik Dong; Choi, Eun Kyung; Chung, Yong An [Dept. of Radiology, Incheon Saint Mary' s HospitalThe Catholic University of Korea, Incheon (Korea, Republic of)

    2017-06-15

    The first step to nuclear medicine in Korea started with introduction of the gamma camera in 1969. Although planar images with the gamma camera give important functional information, they have the limitations that result from 2-dimensional images. Single-photon emission computed tomography (SPECT) due to its 3-dimensional image acquisition is superior to earlier planar gamma imaging in image resolution and diagnostic accuracy. As demand for a hybrid functional and anatomical imaging device has increased, integrated SPECT/CT systems have been used. In Korea, SPECT/CT was for the first time installed in 2003. SPECT/CT can eliminate many possible pitfalls on SPECT-alone images, making better attenuation correction and thereby improving image quality. Therefore, SPECT/CT is clinically preferred in many hospitals in various aspects. More recently, additional SPECT/CT images taken from the region with equivocal uptake on planar images have been helpful in making precise interpretation as part of their clinical workup in postoperative thyroid cancer patients. SPECT and SPECT/CT have various advantages, but its clinical application has gradually decreased in recent few years. While some researchers investigated the myocardial blood flow with cardiac PET using F-18 FDG or N-13 ammonia, myocardial perfusion SPECT is, at present, the radionuclide imaging study of choice for the risk stratification and guiding therapy in the coronary artery disease patients in Korea. New diagnostic radiopharmaceuticals for AD have received increasing attention; nevertheless, brain SPECT will remain the most reliable modality evaluating cerebral perfusion.

  17. Differential diagnosis of posterior fossa brain tumors: Multiple discriminant analysis of Tl-SPECT and FDG-PET.

    Science.gov (United States)

    Yamauchi, Moritaka; Okada, Tomohisa; Okada, Tsutomu; Yamamoto, Akira; Fushimi, Yasutaka; Arakawa, Yoshiki; Miyamoto, Susumu; Togashi, Kaori

    2017-08-01

    This study investigated the combined capability of thallium-201 (Tl)-SPECT and fluorine-18-fluoro-deoxy-glucose (FDG)-PET for differential diagnosis of posterior fossa brain tumors using multiple discriminant analysis.This retrospective study was conducted under approval of the institutional review board. In the hospital information system, 27 patients with posterior fossa intra-axial tumor between January 2009 and June 2015 were enrolled and grouped as the following 7 entities: low grade glioma (LGG) 6, anaplastic astrocytoma (AA) 2, glioblastoma (GBM) 3, medulloblastoma (MB) 3, hemangioblastoma (HB) 6, metastatic tumor (Mets) 3, and malignant lymphoma (ML) 4. Tl and FDG uptakes were measured at the tumors and control areas, and several indexes were derived. Using indexes selected by the stepwise method, discriminant analysis was conducted with leave-one-out cross-validation.The predicted accuracy for tumor classification was 70.4% at initial analysis and 55.6% at cross-validation to differentiate 7 tumor entities. HB, LGG, and ML were well-discriminated, but AA was located next to LGG. GBM, MB, and Mets largely overlapped and could not be well distinguished even applying multiple discriminant analysis. Correct classification in the original and cross-validation analyses was 44.4% and 33.3% for Tl-SPECT and 55.6% and 48.1% for FDG-PET.

  18. Effect of the reverse redistribution pattern on the left ventricular ejection fraction in the Tc- 99m MIBI SPECT myocardial perfusion scintigraphy

    Directory of Open Access Journals (Sweden)

    Bekir Taşdemir

    2015-09-01

    Full Text Available Objective: The causes and prognostic significance of the reverse redistribution pattern (RRP is not clear yet. In this study, we aimed to evaluate the RRP effect on the left ventricular ejection fraction (EF. Methods: Imaging of the patients whose technetium-99m sestamibi myocardial perfusion scintigraphy was carried out and reported as normal were retrospectively examined. One-day protocol and/or pharmacologic stress testing applied patients were excluded. 21 patients with RRP met the inclusion criteria. All of these patients were included in the study as RRP group. Randomly selected 21 patients with non-RRP were included in the study as control group. Transient ischemic dilation (TID scores and EF values were automatically calculated with the Quantitative Gated SPECT (QGS program. Results: While a statistically significant difference was not found between the RRP and control groups in terms of age, sex, hypertension, family history, hyperlipidemia, and diabetes (p>0.05, there was a statistically significant difference in terms of smoking (p=0.019. TID scores in the RRP group were significantly lower compared to the control group (p<0.001. In addition, a statistically significant decrease was determined in the EF values in the rest images compared to the stress images in the RRP group (p=0.002. Furthermore, this decrease was significantly higher than in the control group (p= 0.034. Conclusion: The results related to the TID scores and EF values are suggesting the existence of an ischemic cause in the background of the RRP. Additionally, the relationship found between smoking and RRP may be associated with the tachycardia and / or coronary spasm-inducing effect of smoking. J Clin Exp Invest 2015; 6 (3: 286-290

  19. Assessment of transient ischemic dilation (TID) ratio in gated SPECT myocardial perfusion imaging (MPI) using regadenoson, a new agent for pharmacologic stress testing.

    Science.gov (United States)

    Katz, J S; Ruisi, M; Giedd, K N; Rachko, M

    2012-08-01

    Abnormal values of the transient ischemic dilation (TID) ratio are associated with severe and extensive coronary artery disease (CAD). The objective of this study was to determine the relationship between TID, determined from stress and rest ventricular volumes during regadenoson gated single-photon emission computed tomography myocardial perfusion imaging (MPI) dual isotope studies, and the extent of CAD found during coronary angiography. 195 patients who underwent dual isotope MPI with regadenoson and cardiac angiography between March 2009 and February 2010 were analyzed. TID was calculated using commercially available software, Emory Cardiac Toolbox. Mean TID values were compared across disease types. A threshold for abnormal TID was determined by adding two standard deviations (SDs) to the mean TID of the "non-obstructive CAD" subgroup. In the 195-patient group analyzed, the mean TID ratio for non-obstructive CAD (n = 104) was found to be 1.09 with a SD of 0.15. In a subgroup of patients whose angiogram was within 3 months of MPI (n = 155), the mean TIDs for non-obstructive disease (n = 81), single-vessel disease (n = 35), and multi-vessel disease (n = 39) were 1.09, 1.15, and 1.19 with SDs of 0.16, 0.19, and 0.26, respectively. Those with an abnormal TID had a crude and adjusted odds ratio of 3.4 for multi-vessel disease which was statistically significant. History of diabetes was not found to be a significant confounder, effect modifier, or mediator of the relationship between the TID and the vessel disease. The mean TID ratio in patients with multi-vessel disease was 1.19. The threshold for an abnormal TID was 1.39 with specificity of 95% and sensitivity of 15% for determining multi-vessel CAD status. We conclude that the level of TID in gated SPECT MPI using regadenoson is associated with the degree of CAD on angiography.

  20. Myocardial indium-111-antimyosin uptake in essential hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Uenlue, M.; Temiz, N.H. [Dept. of Nuclear Medicine, Dept. of Nuclear Medicine, Ankara (Turkey); Cengel, A. [Dept. of Cardiology, Gazi Univ. School of Medicine, Dept. of Nuclear Medicine, Ankara (Turkey)

    2003-06-01

    Aim: Evaluation of myocardial uptake of {sup 111}In-antimyosin antibodies in patients with essential hypertension for the verification of our hypothesis that it may increase in stage 1 in the left ventricle as a result of myocardial damage. Patients, methods: Twelve men (mean age: 59 {+-} 2.4 years) suffering from angina like symptoms and essential hypertension in clinical stage 1 according to the JNC-VI criteria were included into the study. These patients showed normal perfusion as revealed by thallium-201 myocardial study and coronary angiography. Left ventricular mass index was determined in echocardiography. Planar antimyosin images were obtained 48 h after the intravenous injection of the tracer. Heart to lung ratios were calculated as a parameter of myocardial tracer uptake using appropriate region of interests; values >1.52 were considered as abnormal. Results: We observed increased antimyosin uptake (mean: 1.71 {+-} 0.12) consistent with myocardial damage in 11 of 12 patients. Nine of 12 patients had a left ventricular hypertrophy with left ventricular mass index values (mean: 131 g/m{sup 2} {+-} 9.48) above 115 g/m{sup 2}. Heart to lung ratio was correlated significantly to left ventricular mass index (r = 0.902, p <0.001) and duration of hypertension (r = 0.948, p <0.001). Conclusion: Our results suggest that {sup 111}In-antimyosin imaging may indicate myocyte damage in early phases of hypertensive heart disease. (orig.)

  1. Clinical values of left ventricular mechanical dyssynchrony assessment by gated myocardial perfusion SPECT in patients with acute myocardial infarction and multivessel disease

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Sang-Geon; Park, Ki Seong; Kim, Jahae; Kim, Jong Sang; Song, Ho-Chun [Chonnam National University Hospital, Department of Nuclear Medicine, Gwang-ju (Korea, Republic of); Jabin, Zeenat; Kang, Sae-Ryung; Kwon, Seong Young; Jeong, Geum-Cheol; Song, Minchul; Min, Jung-Joon; Bom, Hee-Seung [Chonnam National University Hwasun Hospital, Department of Nuclear Medicine, Hwasun-gun, Jeonnam (Korea, Republic of); Cho, Jae Yeong; Kim, Hyun Kuk [Chonnam National University Hospital, Department of Cardiology, Gwang-ju (Korea, Republic of)

    2017-02-15

    The aim of this study was to evaluate the prognostic value of additional evaluation of left ventricular mechanical dyssynchrony (LVMD) by gated myocardial perfusion single-photon emission computed tomography (GMPS) in patients with acute myocardial infarction (MI) and multivessel disease. One hundred and nine acute MI patients with >50 % stenosis in at least one non-culprit artery who underwent GMPS within 2 weeks were enrolled. All patients underwent successful revascularization of the culprit arteries. Those with previous MI, atrial fibrillation, or frequent ventricular premature complexes, cardiac devices, significant patient motion, or procedure-related events were excluded. Phase standard deviation (PSD) and phase histogram bandwidth (PBW) were measured for assessment of LVMD. Patients were followed up for a median of 26 months after index MI, for composite major adverse cardiac events (MACE), which consisted with all-cause death, unplanned hospitalization due to heart failure and severe ventricular arrhythmias (sustained ventricular tachycardia or ventricular fibrillation). Independent predictors of MACE were evaluated. MACE occurred in 22 patients (20 %). Stress PSD (53.3 ± 17.3 vs. 35.3 ± 18.9 ; p <0.001), stress PBW (147.6 ± 54.6 vs. 96.8 ± 59.2 ; p = 0.001) and resting PBW (126.8 ± 37.5 vs. 96.6 ± 48.9 ; p = 0.001) were significantly higher in patients with MACE compared to those without. Multivariate analysis revealed that stress PSD ≥45.5 and stress PBW ≥126.0 were predictive of MACE, as well as suboptimal non-culprit artery revascularization (SNR) and renin-angiotensin system (RAS) blockade medication. Higher stress PSD and stress PBW were associated with poorer prognosis both in patients with and without SNR, and those with RAS blockade medication, but not in those without RAS blockade medication. LVMD measured by GMPS showed added prognostic value in acute MI with multivessel disease. GMPS could serve as a comprehensive evaluation imaging

  2. Specificity and sensitivity of SPECT myocardial perfusion studies at the Nuclear Medicine Department of the Limassol General Hospital in Cyprus

    Energy Technology Data Exchange (ETDEWEB)

    Koumna, S [Athens Anticancer - Oncology Hospital ' AgiosSavvas' , Athens (Greece); Yiannakkaras, Ch [Medical Physics Department, Nicosia General Hospital, Nicosia (Cyprus); Avraamides, P [Cardiology Clinic, Limassol General Hospital, Limassol (Cyprus); Demetriadou, O, E-mail: stelkoum@gmail.com [Nuclear Medicine Department, Limassol General Hospital, Limassol (Cyprus)

    2011-09-23

    The aim is to determine the sensitivity and specificity of Myocardial Perfusion Imaging (MPI) performed at the Nuclear Medicine Department of the Limassol General Hospital in Cyprus. Through a retrospective analysis, patient results obtained by MPI were compared to results obtained by Invasive Angiography. We analyzed data from 96 patients that underwent both MPI and Angiography during the years 2009-2010, with a maximum time interval of {+-} 9 months between the two types of medical exams. For 51 patients, the indication was the detection of CAD. For 45 patients, the indication was to assess viability and/or ischemia after MI, PCI or CABG. Out of 84 patients with CAD confirmed by angiography, 80 patients resulted in abnormal MPI (sensitivity of 95% and positive predictive value of 98%). Out of 12 patients with normal coronaries, 10 patients resulted in normal MPI (specificity of 83% and negative predictive value of 71%).In conclusion, for the patients with abnormal MPI and confirmed CAD, MPI was a useful aid for further therapy management.

  3. Effect of caffeine on SPECT myocardial perfusion imaging during regadenoson pharmacologic stress: a prospective, randomized, multicenter study.

    Science.gov (United States)

    Tejani, Furqan H; Thompson, Randall C; Kristy, Rita; Bukofzer, Stan

    2014-06-01

    A multicenter, double-blind, randomized study was conducted to assess the effect of caffeine on regadenoson stress myocardial perfusion imaging (MPI). Subjects with a high likelihood of coronary artery disease underwent a rest single-photon emission computed tomography MPI on day 1 (MPI-1) and a stress MPI with regadenoson on day 3 (MPI-2). Individuals with ≥1 segment with a reversible defect received double-blind caffeine tablets (200 or 400 mg) or placebo 90 min before a repeat regadenoson stress MPI (MPI-3) on day 5. Overall, 207 subjects completed the study (caffeine 200 mg, n = 70; caffeine 400 mg, n = 71; placebo, n = 66). The mean number of segments with reversible defects decreased from MPI-2 to MPI-3 in the caffeine 200 and 400 mg groups versus no significant change in the placebo group [mean ± standard deviation: -0.61 ± 1.097, -0.62 ± 1.367, and 0.12 ± 0.981, respectively (overall treatment effect, P regadenoson stress MPI.

  4. The Benefits of Prone SPECT Myocardial Perfusion Imaging in Reducing Both Artifact Defects and Patient Radiation Exposure

    Directory of Open Access Journals (Sweden)

    Maria Stathaki

    2015-10-01

    Full Text Available AbstractBackground:Prone imaging has been demonstrated to minimize diaphragmatic and breast tissue attenuation.Objectives:To determine the role of prone imaging on the reduction of unnecessary rest perfusion studies and coronary angiographies performed, thus decreasing investigation time and radiation exposure.Methods:We examined 139 patients, 120 with an inferior wall and 19 with an anterior wall perfusion defect that might represented attenuation artifact. Post-stress images were acquired in both the supine and prone position. Coronary angiography was used as the “gold standard” for evaluating coronary artery patency. The study was terminated and rest imaging was obviated in the presence of complete improvement of the defect in the prone position. Quantitative interpretation was performed. Results were compared with clinical data and coronary angiographic findings.Results:Prone acquisition correctly revealed defect improvement in 89 patients (89/120 with inferior wall and 12 patients (12/19 with anterior wall attenuation artifact. Quantitative analysis demonstrated statistically significant difference in the mean summed stress scores (SSS of supine and mean SSS of prone studies in patients with disappearing inferior wall defect in the prone position and patent right coronary artery (true negative results. The mean difference between SSS in supine and in prone position was higher with disappearing than with remaining defects.Conclusion:Technetium-99m (Tc-99m tetrofosmin myocardial perfusion imaging with the patient in the prone position overcomes soft tissue attenuation; moreover it provides an inexpensive, accurate approach to limit the number of unnecessary rest perfusion studies and coronary angiographies performed.

  5. Increased accuracy of single photon emission computed tomography (SPECT myocardial perfusion scintigraphy using iterative reconstruction of images

    Directory of Open Access Journals (Sweden)

    Stević Miloš

    2016-01-01

    Full Text Available Background/Aim. Filtered back projection (FBP is a common way of processing myocardial perfusion imaging (MPI studies. There are artifacts in FBP which can cause falsepositive results. Iterative reconstruction (IR is developed to reduce false positive findings in MPI studies. The aim of this study was to evaluate the difference in the number of false positive findings in MPI studies, between FBP and IR processing. Methods. We examined 107 patients with angina pectoris with MPI and coronary angiography (CAG, 77 man and 30 woman, aged 32−82. MPI studies were processed with FBP and with IR. Positive finding at MPI was visualization of the perfusion defect. Positive finding at CAG was stenosis of coronary artery. Perfusion defect at MPI without coronary artery stenosis at CAG was considered like false positive. The results were statistically analyzed with bivariate correlation, and with one sample t-test. Results. There were 20.6% normal, and 79.4% pathologic findings at FBP, 30.8% normal and 69.2% pathologic with IR and 37.4% normal and 62.6% pathologic at CAG. FBP produced 19 false-positive findings, at IR 11 false positive findings. The correlation between FBP and CAG was 0.658 (p < 0.01 and between IR and CAG 0.784 (p < 0.01. The number of false positive findings at MPI with IR was significantly lower than at FBP (p < 0.01. Conclusion. Our study shows that IR processing MPI scintigraphy has less number of false positive findings, therefore it is our choice for processing MPI studies.

  6. Detection of myocardial viability by means of Single Proton Emission Computed Tomography (Perfused SPECT) dual {sup 201} Tl (rest of 15 minutes, 24 late hours and 24 hours reinjection) and gated-SPECT {sup 99m} Tc-SESTAMIBI in effort or stimulation of the coronary reserves; Deteccion de viabilidad miocardica mediante tomografia por emision de foton unico (SPECT perfusorio) dual {sup 201} Talio (Reposo de 15 minutos, 24 horas tardio y 24 horas reinyeccion) y gated-SPECT {sup 99m} Tc-SESTAMIBI en esfuerzo o estimulo de reserva coronaria

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza V, R

    2004-07-01

    The objective of this work was to determine if the images of SPECT {sup 201} TI in rest of 15 minutes, 24 late hours and Gated-SPECT {sup 99m} Tc-SESTAMIBI in effort or stimulation of coronary reservation correlate with the study of 24 hours post reinjection of {sup 201}TI to determine the presence of having knitted viable myocardium. Material and methods: 29 patients were studied with coronary arterial illness (EAC) to who are carried out SPECT {sup 201} TI in rest with images of 15 minutes, 24 late hours and 24 hours reinjection, by means of the administration of {sup 201}TI to dose of 130 MBq and reinjection with 37 MBq. and Gated-SPECT {sup 99m}Tc-SESTAMIBI in effort or stimulation of coronary reservation, later to the administration of 1110 MBq. Results: 29 patients were included according to inclusion approaches and exclusion, of those which 22 (75.86%) they correspond at the masculine sex and 7 (24.13%) to the feminine one, with an average of 62.1 year-old age, 2320 segments myocardial were analysed so much it is phase post-effort as rest; they were diagnosed a total of 264 segments with heart attack, of which viability myocardium was observed in 174 segments. The statistical tests are analysis of frequencies. The non parametric test of Wilcoxon and Mann-Whitney. Conclusions: the viability myocardial at the 24 late hours and 24 hours reinjection was similar; significant difference exists between the study of 15 minutes and 24 hours reinjection, ischemic illness was also demonstrated in territories different to the heart attack area in the studies of 15 minutes, late 24 hours and 24 hours reinjection. (Author)

  7. Detection and quantification of acute reperfused myocardial infarction in rabbits using DISA-SPECT/CT and 3.0T cardiac MRI

    National Research Council Canada - National Science Library

    Feng, Yuanbo; Cona, Marlein Miranda; Vunckx, Kathleen; Li, Yue; Chen, Feng; Nuyts, Johan; Gheysens, Olivier; Zhou, Lin; Xie, Yi; Oyen, Raymond; Ni, Yicheng

    2013-01-01

    ...). We explored dual-isotope simultaneous acquisition single photon emission computed tomography/computed tomography (DISA-SPECT/CT) by using (123)I-HYP and standard (99m)Tc-sestamibi ((99m)Tc-MIBI...

  8. Collimator optimization and collimator-detector response compensation in myocardial perfusion SPECT using the ideal observer with and without model mismatch and an anthropomorphic model observer.

    Science.gov (United States)

    Ghaly, Michael; Links, Jonathan M; Frey, Eric C

    2016-03-07

    The collimator is the primary factor that determines the spatial resolution and noise tradeoff in myocardial perfusion SPECT images. In this paper, the goal was to find the collimator that optimizes the image quality in terms of a perfusion defect detection task. Since the optimal collimator could depend on the level of approximation of the collimator-detector response (CDR) compensation modeled in reconstruction, we performed this optimization for the cases of modeling the full CDR (including geometric, septal penetration and septal scatter responses), the geometric CDR, or no model of the CDR. We evaluated the performance on the detection task using three model observers. Two observers operated on data in the projection domain: the Ideal Observer (IO) and IO with Model-Mismatch (IO-MM). The third observer was an anthropomorphic Channelized Hotelling Observer (CHO), which operated on reconstructed images. The projection-domain observers have the advantage that they are computationally less intensive. The IO has perfect knowledge of the image formation process, i.e. it has a perfect model of the CDR. The IO-MM takes into account the mismatch between the true (complete and accurate) model and an approximate model, e.g. one that might be used in reconstruction. We evaluated the utility of these projection domain observers in optimizing instrumentation parameters. We investigated a family of 8 parallel-hole collimators, spanning a wide range of resolution and sensitivity tradeoffs, using a population of simulated projection (for the IO and IO-MM) and reconstructed (for the CHO) images that included background variability. We simulated anterolateral and inferior perfusion defects with variable extents and severities. The area under the ROC curve was estimated from the IO, IO-MM, and CHO test statistics and served as the figure-of-merit. The optimal collimator for the IO had a resolution of 9-11 mm FWHM at 10 cm, which is poorer resolution than typical collimators

  9. Stress-first protocol for myocardial perfusion SPECT imaging with semiconductor cameras: high diagnostic performances with significant reduction in patient radiation doses

    Energy Technology Data Exchange (ETDEWEB)

    Perrin, Mathieu; Claudin, Marine; Veran, Nicolas; Morel, Olivier; Besseau, Cyril; Boutley, Henri [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); Nancyclotep Experimental Imaging Platform, Nancy (France); Djaballah, Wassila; Poussier, Sylvain; Verger, Antoine [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); Nancyclotep Experimental Imaging Platform, Nancy (France); INSERM U947 et Universite de Lorraine, Nancy (France); Moulin, Frederic [CHU-Nancy, Department of Cardiology, Nancy (France); Imbert, Laetitia; Karcher, Gilles [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); Nancyclotep Experimental Imaging Platform, Nancy (France); UMR 7039 CRAN et Universite de Lorraine, Nancy (France); Marie, Pierre-Yves [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); Nancyclotep Experimental Imaging Platform, Nancy (France); INSERM U1116 et Universite de Lorraine, Nancy (France)

    2015-02-25

    Effective doses of 14 mSv or higher are currently being attained in patients having stress and rest myocardial perfusion imaging (MPI) single photon emission computed tomography (SPECT) performed on the same day with conventional protocols. This study aimed to assess the actual reduction in effective doses as well as diagnostic performances for MPI routinely planned with: (1) high-sensitivity cadmium zinc telluride (CZT) cameras, (2) very low injected activities and (3) a stress-first protocol where the normality of stress images may lead to avoiding rest imaging. During a 1-year period, 2,845 patients had MPI on a CZT camera, a single-day stress-first protocol and low injected activities (120 MBq of {sup 99m}Tc-sestamibi at stress for 75 kg body weight and threefold higher at rest). The ability to detect > 50 % coronary stenosis was assessed in a subgroup of 149 patients who also had coronary angiography, while the normalcy rate was assessed in a subgroup of 128 patients with a low pretest likelihood of coronary artery disease (<10 %). Overall, 33 % of patients had abnormal MPI of which 34 % were women and 34 % were obese. The mean effective doses and the percentage of exams involving only stress images were: (1) 3.53 ± 2.10 mSv and 37 % in the overall population, (2) 4.83 ± 1.56 mSv and 5 % in the subgroup with angiography and (3) 1.96 ± 1.52 mSv and 71 % in the low-probability subgroup. Sensitivity and global accuracy for identifying the 106 patients with coronary stenosis were 88 and 80 %, respectively, while the normalcy rate was 97 %. When planned with a low-dose stress-first protocol on a CZT camera, MPI provides high diagnostic performances and a dramatic reduction in patient radiation doses. This reduction is even greater in low-risk subgroups with high rates of normal stress images, thus allowing the mean radiation dose to be balanced against cardiac risk in targeted populations. (orig.)

  10. Early and Delayed Myocardial Enhancement in Myocardial Infarction Using Two-Phase Contrast-Enhanced Multidetector-Row CT

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Sung-Min; Kim, Young-Whan; Han, Seong-Wook [University of Keimyung College of Medicine, Dongsan Medical Center, Daegu (Korea, Republic of); Seo, Joon-Beom [University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2007-04-15

    The purpose of this study was to describe the myocardial enhancement patterns in patients with myocardial infarction using two-phase contrast enhanced multidetector-row computed tomography (MDCT). Twenty-three patients with clinically proven myocardial infarction (17 acute myocardial infarction [AMI] and 6 chronic myocardial infarction [CMI]) were examined with two-phase contrast-enhanced ECG-gated MDCT. The presence, location, and patterns of myocardial enhancement on two phase MDCT images were compared with infarcted myocardial territories determined by using electrocardiogram, echocardiography, thallium-201 single photon emission computed tomography, catheter and MDCT coronary angiography. After clinical assessment, the presence of myocardial infarctions were found in 27 territories (19 AMI and 8 CMI) of 23 patients. Early perfusion defects were observed in 30 territories of all 23 patients. Three territories not corresponding to a myocardial infarction were detected in three patients with AMI and were associated with artifacts. Fourteen of perfusion defects were in the left anterior descending artery territory, four in the left circumflex artery territory, and nine in the right coronary artery territory. Delayed enhancement was observed in 25 territories (17 AMI and 8 CMI) of 21 patients. Delayed enhancement patterns were variable. Transmural early perfusion defects (n =12) were closely associated with transmural late enhancement (n = 5) and subendocardial residual defect with subepicardial late enhancement (n = 5). Myocardial infarction showed early perfusion defects and variable delayed enhancement patterns on two-phase contrast-enhanced MDCT. Delayed enhancement technique of MDCT could provide additional information of the location and extent of infarcted myocardium, and could be useful to plan appropriate therapeutic strategies in patients with AMI.

  11. Myocardial metabolic abnormalities in hypertrophic cardiomyopathy assessed by iodine-123-labeled beta-methyl-branched fatty acid myocardial scintigraphy and its relation to exercise-induced ischemia

    Energy Technology Data Exchange (ETDEWEB)

    Matsuo, Shinro; Nakamura, Yasuyuki; Takahashi, Masayuki; Mitsunami, Kenichi; Kinoshita, Masahiko [Shiga Univ. of Medical Science, Otsu (Japan)

    1998-03-01

    Reversible thallium-201 ({sup 201}Tl) abnormalities during exercise stress have been used as markers of myocardial ischemia in hypertrophic cardiomyopathy (HCM) and are most likely to identify relatively underperfused myocardium. Although metabolic abnormalities in HCM were reported, the relationship between impaired energy metabolism and exercise-induced ischemia has not been fully elucidated as yet. To assess the relationship between myocardial perfusion abnormalities and fatty acid metabolic abnormalities, 28 patients with HCM underwent exercise {sup 201}Tl and rest {sup 123}I-15-(p-iodophenyl)-3-methyl pentadecanoic acid (BMIPP) scintigraphy. Perfusion abnormalities were observed by exercise {sup 201}Tl in 19/28 patients with HCM. {sup 123}I-BMIPP uptake was decreased compared with delayed {sup 201}Tl in 106/364 (29%) of the total myocardial segments (p<0.01, McNemar symmetry test). Such disparity between {sup 123}I-BMIPP and {sup 201}Tl was observed more often in the 49/75 (65%) segments with reversible exercise {sup 201}Tl defects (p<0.001). Our results indicate that exercise-induced myocardial ischemia exists in HCM, resulting in metabolic abnormalities. The combination of {sup 123}I-BMIPP and {sup 201}Tl suggests that myocardial ischemia may play an important role in metabolic abnormalities in HCM. (author)

  12. Myocardial perfusion abnormalities in asymptomatic type 2 diabetic patients

    Directory of Open Access Journals (Sweden)

    Ghada Al-Humaidi

    2018-01-01

    Conclusions: We found a high prevalence of myocardial perfusion abnormalities in asymptomatic type 2 diabetic patients. Perfusion abnormalities on myocardial perfusion SPECT images were associated with disease duration, insulin use, nephropathy, and neuropathy. Asymptomatic diabetic patients might be candidates with CAD abnormalities that can be studied using myocardial perfusion SPECT.

  13. Evaluation of general-purpose collimators against high-resolution collimators with resolution recovery with a view to reducing radiation dose in myocardial perfusion SPECT: A preliminary phantom study.

    Science.gov (United States)

    Armstrong, Ian S; Saint, Kimberley J; Tonge, Christine M; Arumugam, Parthiban

    2017-04-01

    There is a growing focus on reducing radiation dose to patients undergoing myocardial perfusion imaging. This preliminary phantom study aims to evaluate the use of general-purpose collimators with resolution recovery (RR) to allow a reduction in patient radiation dose. Images of a cardiac torso phantom with inferior and anterior wall defects were acquired on a GE Infinia and Siemens Symbia T6 using both high-resolution and general-purpose collimators. Imaging time, a surrogate for administered activity, was reduced between 35% and 40% with general-purpose collimators to match the counts acquired with high-resolution collimators. Images were reconstructed with RR with and without attenuation correction. Two pixel sizes were also investigated. Defect contrast was measured. Defect contrast on general-purpose images was superior or comparable to the high-resolution collimators on both systems despite the reduced imaging time. Infinia general-purpose images required a smaller pixel size to be used to maintain defect contrast, while Symbia T6 general-purpose images did not require a change in pixel size to that used for standard myocardial perfusion SPECT. This study suggests that general-purpose collimators with RR offer a potential for substantial dose reductions while providing similar or better image quality to images acquired using high-resolution collimators.

  14. Technological Development and Advances in SPECT/CT

    Science.gov (United States)

    Seo, Youngho; Aparici, Carina Mari; Hasegawa, Bruce H

    2010-01-01

    SPECT/CT has emerged over the past decade as a means of correlating anatomical information from CT with functional information from SPECT. The integration of SPECT and CT in a single imaging device facilitates anatomical localization of the radiopharmaceutical to differentiate physiological uptake from that associated with disease and patient-specific attenuation correction to improve the visual quality and quantitative accuracy of the SPECT image. The first clinically available SPECT/CT systems performed emission-transmission imaging using a dual-headed SPECT camera and a low-power x-ray CT sub-system. Newer SPECT/CT systems are available with high-power CT sub-systems suitable for detailed anatomical diagnosis, including CT coronary angiography and coronary calcification that can be correlated with myocardial perfusion measurements. The high-performance CT capabilities also offer the potential to improve compensation of partial volume errors for more accurate quantitation of radionuclide measurement of myocardial blood flow and other physiological processes and for radiation dosimetry for radionuclide therapy. In addition, new SPECT technologies are being developed that significantly improve the detection efficiency and spatial resolution for radionuclide imaging of small organs including the heart, brain, and breast, and therefore may provide new capabilities for SPECT/CT imaging in these important clinical applications. PMID:18396178

  15. The natural history of takotsubo syndrome: a two-year follow-up study with myocardial sympathetic and perfusion G-SPECT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Sestini, Stelvio; Mazzeo, Christian; Castagnoli, Antonio [Nuclear Medicine Unit, N.O.P. - S. Stefano, U.S.L. Toscana Centro, Deptartment of Diagnostic Imaging, Prato (Italy); Pestelli, Francesco; Leoncini, Mario; Bellandi, Francesco [Cardiovascular Unit, N.O.P. - S. Stefano, U.S.L, Toscana Centro, Deptartment of Internal Medicine, Prato (Italy); Mansi, Luigi [Nuclear Medicine Unit, University II Naples, Deptartment of Diagnostic Imaging, Naples (Italy); Carrio, Ignasi [Hospital Sant Pau, Nuclear Medicine, Barcelona (Spain)

    2017-02-15

    To investigate changes in sympathetic activity, perfusion, and left ventricular (LV) functionality in takotsubo cardiomyopathy (TTC) patients from onset (T{sub 0}) to post-onset conditions at 1 month (T{sub 1}), 1-2 years (T{sub 2}, T{sub 3}). Twenty-two patients (70 ± 11 years) underwent serial gated single photon emission tomography (G-SPECT) studies with {sup 123}I-mIBG and {sup 99m}Tc-Sestamibi. Statistics were performed using ANOVA/Sheffe post-hoc, correlation test, and receiver operating characteristic (ROC) curve analysis (p < 0.05). Patients presented at T{sub 0} with LV ballooning and reduced early-late mIBG uptake (95%, 100%), left ventricular ejection fraction (LVEF){sub G-SPECT} (86%) and perfusion (77 %). Adrenergic dysfunction was greater in apex, it overlaps with contractile impairment, and both were more severe than perfusion defect. During follow-up, LVEF{sub G-SPECT}, contractility, and perfusion were normal, while 82% and 90% of patients at T{sub 1} and 50% at T{sub 2} and T{sub 3} continued to show a reduced apical early-late mIBG distribution. These patients presented at T{sub 0}-T{sub 1} with greater impairment of adrenergic function, contractility, and perfusion. A relationship was present within innervation and both perfusion and contractile parameters at T{sub 0} and T{sub 1}, and between the extent of adrenergic defect at T{sub 3} and both the defect extent and age at T{sub 0} (cut-off point 42.5%, 72 years). Outcome for TTC is not limited to a reversible contractile and perfusion abnormalities, but it includes residual adrenergic dysfunction, depending on the level of adrenergic impairment and age of patients at onset. The number of patients, as well as degree of perfusion abnormalities were found to be higher than those previously reported possibly depending on the time-interval between hospital admission and perfusion scan. (orig.)

  16. Influence of myocardial infarction size on radionuclide and Doppler echocardiographic measurements of diastolic function

    Energy Technology Data Exchange (ETDEWEB)

    Johannessen, K.A.; Cerqueira, M.D.; Stratton, J.R. (Seattle Veterans Administration Medical Center, WA (USA))

    1990-03-15

    To assess the relation between myocardial infarction size and diastolic function as measured by radionuclide ventriculography and Doppler echocardiography, 83 patients (aged 58 +/- 9 years) without significant valvular disease were studied 8 to 12 weeks after an acute myocardial infarction. Myocardial infarction size was measured by resting thallium-201 tomography. Peak early filling rate (in end-diastolic volumes/s) was measured by gated blood pool scintigraphy. Doppler measures of mitral inflow were peak early (E) and atrial (A) filling velocities, slopes of E and A, percent E and A filling, E/A ratio and diastolic filling period. In univariate analyses, there was a significant inverse correlation between infarction size and the peak early filling rate (r = -0.59, p less than 0.001), and this remained significant (r = -0.63, p less than 0.0001) in an analysis that included 2 other determinants of the filling rate, age and diastolic filling period. Infarction size was directly correlated to the peak E velocity (r = 0.37, p less than 0.01), deceleration of E (r = 0.41, p less than 0.01) and percent E filling (r = 0.31, p less than 0.01), and was inversely correlated to peak A (r = -0.27, p less than 0.05) and percent A filling (r = -0.26, p less than 0.05).

  17. Emergency coronary bypass grafting for evolving myocardial infarction. Effects on infarct size and left ventricular function

    Energy Technology Data Exchange (ETDEWEB)

    Flameng, W.; Sergeant, P.; Vanhaecke, J.; Suy, R.

    1987-07-01

    Emergency aorta-coronary bypass grafting was performed early in the course of evolving myocardial infarction in 48 patients. The time interval between the onset of symptoms and reperfusion was 169 +/- 80 minutes. Quantitative assessment of postoperative thallium 201 myocardial scans in 19 patients revealed a significant salvage of myocardium after surgical reperfusion: The size of the residual infarction was less than 50% of that in a matched, medically treated, prospective control group (n = 39) (p less than 0.05). Postoperative equilibrium-gated radionuclide blood pool studies (technetium 99m) showed an enhanced recovery of regional and global ejection fraction after operation as compared to after medical treatment (p less than 0.05). Ultrastructural evaluation of biopsy specimens obtained during the operation delineated subendocardial necrosis in the majority of cases (72%), but subepicardial necrosis was found in only 6% of instances. Q-wave abnormalities were observed on the postoperative electrocardiogram in 50% of cases. Operative mortality was 0% in low-risk patients (i.e., hemodynamically stable condition, n = 26) and 18% in high-risk patients (i.e., cardiogenic shock including total electromechanical dysfunction, n = 22). Survival rate at 18 months was 92% +/- 4%, and 95% +/- 4% of the survivors were event free. It is concluded that early surgical reperfusion of evolving myocardial infarction limits infarct size significantly, enhances functional recovery, and may be a lifesaving operation in patients having cardiogenic shock associated with unsuccessful resuscitation.

  18. Myocardial fatty acid imaging using iodine-123-BMIPP in patients with hypertensive intracranial hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Hashizume, Toshikazu; Sakai, Yasuhito; Hayashi, Yasushi [National Minamiwakayama Hospital, Tanabe (Japan)

    2000-07-01

    An evaluation of myocardial fatty acid metabolism in hypertensive patients with major complication has not been previously established. To assess the myocardial fatty acid metabolism in hypertensive patients with intracranial hemorrhage (IH), we performed myocardial image using {sup 123}I-15-p-iodophenyl-3-methyl pentadecanoic acid (BMIPP). Seventeen hypertensive patients with IH (HIH) and 27 hypertensive patients without IH (HT) were studied. A dose of 111 MBq of BMIPP was injected intravenously at rest, and a myocardial image was recorded 30 minutes after the injection. Myocardial perfusion image using Thallium-201 (Tl) was also performed within 2 weeks after BMIPP study. The regional myocardial uptakes of BMIPP and Tl were visually assessed in 17 segments with a four-point scoring system (0=absent to 3=normal uptake). Cardiac hypertrophy was evaluated by electrocardiogrpahy (ECG) and two-dimensional ultrasonic cardiography (UCG). Sum of uptake scores of Tl was similar in both groups (45.1{+-}5.4 vs. 47.9{+-}4.2), but that of BMIPP in HIH was lower than HT (35.9{+-}7.9 vs 45.6{+-}4.8, p<0.001). Evaluation of cardiac hypertrophy using ECG and UCG revealed no significant difference between two groups. HIH have much more eccentric hypertrophy in UCG study than HT (53% vs. 37%). These data suggest that hypertensive patients with intracranial hemorrhage have a more impaired myocardial fatty acid metabolism compared to the hypertensive patients with similar cardiac hypertrophy. BMIPP imaging might be useful to evaluate the severity of myocardial fatty acid metabolism in hypertensive patients. (author)

  19. The benefits of prone SPECT myocardial perfusion imaging in reducing both artifact defects and patient radiation exposure; Beneficio da aquisicao de imagem na posicao Prona em perfusao miocardica com SPECT para reducao de artefatos e exposicao do paciente a radiacao

    Energy Technology Data Exchange (ETDEWEB)

    Stathaki, Maria; Koukouraki, Sophia; Papadaki, Emmanouela; Tsaroucha, Angeliki; Karkavitsas, Nikolaos, E-mail: mariast_cha@yahoo.gr [Department of Nuclear Medicine, University Hospital of Heraklion, Crete (Greece)

    2015-10-15

    Background: Prone imaging has been demonstrated to minimize diaphragmatic and breast tissue attenuation. Objectives: To determine the role of prone imaging on the reduction of unnecessary rest perfusion studies and coronary angiographies performed, thus decreasing investigation time and radiation exposure. Methods: We examined 139 patients, 120 with an inferior wall and 19 with an anterior wall perfusion defect that might represented attenuation artifact. Post-stress images were acquired in both the supine and prone position. Coronary angiography was used as the 'gold standard' for evaluating coronary artery patency. The study was terminated and rest imaging was obviated in the presence of complete improvement of the defect in the prone position. Quantitative interpretation was performed. Results were compared with clinical data and coronary angiographic findings. Results: Prone acquisition correctly revealed defect improvement in 89 patients (89/120) with inferior wall and 12 patients (12/19) with anterior wall attenuation artifact. Quantitative analysis demonstrated statistically significant difference in the mean summed stress scores (SSS) of supine and mean SSS of prone studies in patients with disappearing inferior wall defect in the prone position and patent right coronary artery (true negative results). The mean difference between SSS in supine and in prone position was higher with disappearing than with remaining defects. Conclusion: Technetium-99m (Tc-99m) tetrofosmin myocardial perfusion imaging with the patient in the prone position overcomes soft tissue attenuation; moreover it provides an inexpensive, accurate approach to limit the number of unnecessary rest perfusion studies and coronary angiographies performed. (author)

  20. Arm exercise testing with myocardial scintigraphy in asymptomatic patients with peripheral vascular disease.

    Science.gov (United States)

    Goodman, S; Rubler, S; Bryk, H; Sklar, B; Glasser, L

    1989-04-01

    Arm exercise with myocardial scintigraphy and oxygen consumption determinations was performed by 33 men with peripheral vascular disease, 40 to 74 years of age (group 2). None had evidence of coronary disease. Nineteen age-matched male control subjects (group 1) were also tested to determine the normal endurance and oxygen consumption during arm exercise in their age group and to compare the results with those obtained during a standard treadmill performance. The maximal heart rate, systolic blood pressure, pressure rate product, and oxygen consumption were all significantly lower for arm than for leg exercise. However, there was good correlation between all these parameters for both types of exertion. The maximal heart rate, work load and oxygen consumption were greater for group 1 subjects than in patients with peripheral vascular disease despite similar activity status. None of the group 1 subjects had abnormal arm exercise ECGs, while six members of group 2 had ST segment changes. Thallium-201 scintigraphy performed in the latter group demonstrated perfusion defects in 25 patients. After nine to 29 months of follow-up, three patients who had abnormal tests developed angina and one of them required coronary bypass surgery. Arm exercise with myocardial scintigraphy may be an effective method of detecting occult ischemia in patients with peripheral vascular disease. Those with good exercise tolerance and no electrocardiographic changes or 201T1 defects are probably at lower risk for the development of cardiac complications, while those who develop abnormalities at low exercise levels may be candidates for invasive studies.

  1. Dobutamine stress radionuclide ventriculography reveals silent myocardial dysfunction in Kawasaki disease

    Energy Technology Data Exchange (ETDEWEB)

    Hamamichi, Yuji; Ichida, Fukiko; Tsubata, Shinichi [Toyama Medical and Pharmaceutical Univ., Sugitani (Japan). Faculty of Medicine] (and others)

    2002-01-01

    Dobutamine (DOB) stress radionuclide ventriculography (RVG) is proposed for evaluating left ventricular performance in patients with Kawasaki disease (KD). Dobutamine stress RVG, up to 15{mu}g{center_dot}kg{sup -1}{center_dot}min{sup -1}, was performed in 40 patients with a history of KD, some of whom had a perfusion defect (PD group) on dipyridamole stress thallium-201 myocardial imaging, some of whom had no perfusion defects (NPD group), and some of whom had no coronary artery lesions (C group). No significant differences in either systolic or diastolic indices of the left ventricle at rest were observed between the 3 groups. Although hemodynamic responses were similar in all patients after DOB stress, early diastolic index of the first third filling fraction decreased only in the PD group and was significantly lower in this group compared with the C group (p<0.01). The asynchrony index increased significantly in those patients with coronary stenosis after DOB stress (p<0.05). No serious side-effects were observed during the study. Even late after onset, patients with myocardial ischemia as a result of KD still had impaired early diastolic filling and asynchronous relaxation of the left ventricle. As an alternative to exercise testing, DOB stress RVG is a safe and promising means for serially evaluating left ventricular performance in patients with KD. (author)

  2. Impact of integrating heart rate response with perfusion imaging on the prognostic value of regadenoson SPECT myocardial perfusion imaging in patients with end-stage renal disease.

    Science.gov (United States)

    Gomez, Javier; Fughhi, Ibtihaj; Campagnoli, Tania; Ali, Amjad; Doukky, Rami

    2017-10-01

    We investigated whether integrating heart rate response (HRR) to regadenoson with myocardial perfusion imaging (MPI) analysis can enhance risk prediction in end-stage renal disease (ESRD) patients. We prospectively followed 303 ESRD patients after regadenoson stress MPI for a mean of 35 months. Normal HRR to regadenoson was defined as ≥28% increase from baseline. Normal MPI was defined as a summed stress score ≤3 and left ventricular ejection fraction ≥50%. The study cohort was divided in four groups based on various combinations of normal/abnormal HRR and MPI. There was a step-wise increase in the risk of primary endpoint of all-cause death and the composite secondary endpoint of cardiac death or myocardial infarction; patients with Normal MPI/Normal HRR had the lowest event rates and those with Abnormal MPI/Abnormal HRR had the highest, whereas subjects with Abnormal MPI/Normal HRR and Normal MPI/Abnormal HRR had intermediate event rates. This pattern was maintained after adjusting for important clinical covariates. In ESRD patients, integrating HRR to vasodilator stress with MPI interpretation improves risk stratification. Normal HRR/Normal MPI identify truly low-risk group, whereas abnormal MPI or abnormal HRR portrays elevated risk.

  3. Feasibility and diagnostic accuracy of Ecg-gated SPECT myocardial perfusion imaging by a two-hour protocol: The Myofast study;Faisabilite et precision diagnostique d'un protocole de scintigraphie myocardique synchronisee a l'ECG en deux heures: l'etude Myofast

    Energy Technology Data Exchange (ETDEWEB)

    Dunet, V.; Costo, S.; Sabatier, R.; Grollier, G.; Bouvard, G.; Agostini, D. [CHU Cote-de-Nacre, Service de medecine nucleaire, 14 - Caen (France)

    2010-04-15

    Aim of the study: To assess the feasibility of early stress and rest myocardial perfusion and function study using a fast {sup 99m}Tc-tetrofosmin gated-SPECT protocol in patients with known coronary artery disease. Materials and methods: Forty-three patients (pts) (37 M, 6 F, mean age 63.8 +- 9.8 years) underwent a {sup 99m}Tc-Tetrofosmin gated-SPECT (Axis Picker-Philips) myocardial study and a coronary angiography (C.A.) within 3 months. Images were acquired (LEHR, eight bins, 40 sec per image) after injection of {sup 99m}Tc-tetrofosmin (200 to 380 MBq) early (15 min) post-stress (36 dipyridamole, two dobutamine and five ergo-metric stress), and at rest after {sup 99m}Tc-tetrofosmin reinjection (600 to 1150 MBq), in a total time not exceeding 2 hours. Processing was performed with Q.G.S. software using the 17-segment model. Pathological study was defined as a summed difference score (SDS) greater than or equal to 4 4, a fixed defect with summed rest score greater than or equal to 4 and/or L.V. dysfunction defined as myocardial stunning (variation between stress and rest L.V.E.F. greater than or equal to 4 5%), stress L.V.E.F. less than or equal to 45% or rest L.V.E.F. less than or equal to 40%. Results were compared with C.A., and stenosis greater than or equal to 4 50% was considered as significant. Results: For 100% the quality of SPECT imaging was good or excellent. For six patients gating was impossible because of arrhythmia. The overall sensitivity, specificity and accuracy were 95%, 50%, and 91%, respectively. The concordance between gated SPECT and C.A. was moderate (kappa = 0.45, S.E. = 0.15). Interestingly, early-gated acquisition permitted to underline left ventricular dysfunction in 11 cases (30%), of whom eight had poly vascular disease. Stunning was detected in six of 37 cases (16%), of whom six had poly vascular disease. Conclusion: A one-day two-hour {sup 99m}Tc-tetrofosmin gated-SPECT protocol to assess left ventricular perfusion and function is

  4. Clinical validation of simultaneous dual-isotope myocardial scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Weinmann, Pierre; Moretti, Jean Luc [Department of Nuclear Medicine, Avicenne Hospital, Paris XIII University, 125, Rue de Stalingrad, 93 009 Bobigny Cedex (France); Faraggi, Marc [Department of Nuclear Medicine, Bichat Hospital, Paris VII University (France); Hannequin, Pascal [Centre d' Imagerie Nucleaire, Annecy (France)

    2003-01-01

    Simultaneous dual-isotope (rest thallium-201/stress technetium-99m sestamibi) myocardial single-photon emission tomography (SPET) would be an ideal procedure; however, {sup 99m}Tc cross-talk on the {sup 201}Tl window hampers its routine use. Photon energy recovery (PER) is a spectral deconvolution technique validated for scatter and cross-talk removal in phantom studies and a limited series of patients. In this study we aimed to validate the technique in 295 patients within a context of clinical routine practice. Conventional separate rest {sup 201}Tl myocardial SPET data sets were visually compared with simultaneous dual-isotope data sets corrected by PER. Conventional separate rest {sup 201}Tl data sets were identical to dual PER-corrected {sup 201}Tl data sets in 173 (58.6%) patients. As dual PER {sup 201}Tl data sets are corrected for {sup 99m}Tc cross-talk but also for {sup 201}Tl scatter, they were compared with separate rest {sup 201}Tl data sets corrected by PER in the 122 discordant patients. No difference was found in 77 (26.1%) patients. In 26 (8.8%) patients, the difference consisted in the presence of a defect on dual PER {sup 201}Tl data sets only, mirroring an ischaemic defect on {sup 99m}Tc-sestamibi data sets. This difference can be attributed to the influence of stress on the kinetics of {sup 201}Tl injected at rest. In the remaining 19 (6.4%) patients, the difference between separate and simultaneous PER-corrected data sets was scored as mild in 11 and moderate in eight patients and seemed to be related to multiple methodological factors. It is concluded that PER correctly removes {sup 99m}Tc cross-talk. With the addition of an appropriate attenuation correction, the PER technique may allow the routine use of simultaneous dual-isotope myocardial scintigraphy in the near future. (orig.)

  5. A comparison of the clinical relevance of thallium- 201 and ...

    African Journals Online (AJOL)

    1990-09-01

    Sep 1, 1990 ... group of 20 patients, who underwent both 201TI single photon emission computed tomography and 99mTc_MIBI study as well as coronary angiography. The sensitivity for predicting a lesion ranged from 25% to 88% in different areas of the heart and was comparable for the two radiophannaceuticals. The.

  6. Left ventricular function in response to dipyridamole stress: head-to-head comparison between {sup 82}Rubidium PET and {sup 99m}Tc-sestamibi SPECT ECG-gated myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Giorgi, Maria Clementina; Meneghetti, Jose Claudio; Soares, Jose; Izaki, Marisa; Falcao, Andrea; Imada, Rodrigo; Chalela, William; Oliveira, Marco Antonio de; Nomura, Cesar [Department of Radiology and Nuclear Medicine and Molecular Imaging Service - Heart Institute of the University of Sao Paulo Medical School, Sao Paulo (Brazil); Verberne, Hein J. [University of Amsterdam, Department of Nuclear Medicine, Academic Medical Center, P.O. Box 22700, Amsterdam (Netherlands)

    2017-05-15

    Myocardial perfusion imaging (MPI) with {sup 99m}Tc-sestamibi (sestamibi) SPECT and rubidium-82 ({sup 82}Rb) PET both allow for combined assessment of perfusion and left ventricular (LV) function. We sought to compare parameters of LV function obtained with both methods using a single dipyridamole stress dose. A group of 221 consecutive patients (65.2 ± 10.4 years, 52.9% male) underwent consecutive sestamibi and {sup 82}Rb MPI after a single dipyridamole stress dose. Sestamibi and {sup 82}Rb summed rest (SRS), stress (SSS) and difference (SDS) scores, and LV end-diastolic (EDV) and end-systolic (ESV) volumes and left ventricular ejection fraction (LVEF) were compared. Bland-Altman analysis showed that with increasing ESV and EDV the difference between the two perfusion tracers increased both at rest and post-stress. The mean difference in EDV and ESV between the two perfusion tracers at rest could both be independently explained by the {sup 82}Rb SDS and the sestamibi SRS. The combined models explained approximately 30% of the variation in these volumes between the two perfusion tracers (R{sup 2} = 0.261, p = 0.005; R{sup 2} = 0.296, p < 0.001, for EDV and ESV respectively). However, the mean difference in LVEF between sestamibi and {sup 82}Rb showed no significant trend post-stress (R{sup 2} = 0.001, p = 0.70) and only a modest linear increase with increasing LVEF values at rest (R{sup 2} = 0.032, p = 0.009). Differences in left ventricular volumes between sestamibi and {sup 82}Rb MPI increase with increasing volumes. However, these differences did only marginally affect LVEF between sestamibi and {sup 82}Rb. In clinical practice these results should be taken into account when comparing functional derived parameters between sestamibi and {sup 82}Rb MPI. (orig.)

  7. Comparison of correction techniques for simultaneous {sup 201}Tl/{sup 99m}Tc myocardial perfusion SPECT imaging: a dog study

    Energy Technology Data Exchange (ETDEWEB)

    Knesaurek, Karin; Machac, Josef [Division of Nuclear Medicine, The Mount Sinai Medical Center, New York (United States)

    2000-11-01

    We compared two correction methods for simultaneous {sup 201}Tl/{sup 99m}Tc dual-isotope single-photon emission computed tomography (SPECT). Both approaches use the information from the third energy window placed between the photopeak windows of the {sup 201}Tl and {sup 99m}Tc. The first approach, described by Moore et al, corrects only for the contribution of the {sup 99m}Tc to the {sup 201}Tl primary 70 keV window. We developed the three-window transformation dual-isotope correction method, which is a simultaneous cross-talk correction. The two correction methods were compared in a simultaneous {sup 201}Tl/{sup 99m}Tc sestamibi cardiac dog study. Three separate acquisitions were performed in this dog study: two single-isotope and one dual-isotope acquisition. The {sup 201}Tl single-isotope images were used as references. The total number of counts, and the contrast between the left ventricular cavity (LVC) and the myocardium, were used in 70 keV short-axis slices as parameters for evaluating the results of the dual-isotope correction methods. Three consecutive short-axis slices were used to calculate averaged contrast and the averaged total number of counts. The total number of the counts was 667 000 {+-} 500 and 414 500 {+-} 400 counts for the dual-isotope ({sup 201}Tl + {sup 99m}Tc) and single-isotope ({sup 201}Tl-only) 70 keV images, respectively. The corrected dual-isotope images had 514 700 {+-} 700 and 368 000 {+-} 600 counts for Moore's correction and our approach, respectively. Moore's method improved contrast in the dual-isotope 70 keV image to 0.14 {+-} 0.03 from 0.11 {+-} 0.02, which was the value in the 70 keV non-corrected dual-isotope image. Our method improved the same contrast to 0.22 {+-} 0.03. The contrast in the {sup 201}Tl single-isotope 70 keV image was 0.28 {+-} 0.02. Both methods improved the 70 keV dual-isotope images. However, our approach provided slightly better images than Moore's correction when compared with {sup 201

  8. Avaliação da perfusão e função miocárdicas em vítimas de escorpionismo utilizando o Gated-SPECT Evaluación de la perfusión y función miocárdicas en víctimas de escorpionismo utilizando el Gated-SPECT Assessment of myocardial perfusion and function in victims of scorpion envenomation using Gated-SPECT

    Directory of Open Access Journals (Sweden)

    Alexandre Baldini de Figueiredo

    2010-04-01

    are the major causes of death of patients with scorpion envenomation, whose pathophysiological mechanism remains controversial. OBJECTIVE: To investigate the correlation between myocardial perfusion abnormalities and left ventricular contractile function in victims of scorpion envenomation. METHODS: Fifteen patients underwent ECG-gated myocardial perfusion scintigraphy (gated SPECT within 72 hours of, and 15 days after scorpion envenomation. Images were analyzed by means of a semi-quantitative visual perfusion score (0 = normal, 4 = absent and motion score (0 = normal, 4 = akinesia, using the 17-segment model. Summed perfusion (SPS and summed motion (SMS scores were calculated for each patient. Ejection fraction (LVEF was calculated by a commercially available software. RESULTS: At baseline, 12 out of the 15 patients presented abnormal myocardial perfusion and contractility. Mean values of SPS, SMS and LVEF were 12.5 ± 7.3, 17.0 ± 12.8, and 44.6 ± 16.0%, respectively. A positive correlation between SPS and SMS (r = 0.68; p = 0.005 and negative correlation between SPS and LVEF (r = -0.75; p = 0.0021 were found. The follow-up studies showed recovery of global contractility (LVEF of 68.9 ± 9.5, p = 0.0002, segmental contractility (SMS of 2.6 ± 3.1, p = 0.0009 and perfusion (SPS of 3.7 ± 3.3, p = 0.0003. Improvement of LVEF correlated positively with improvement of SPS (r = 0.72; p = 0.0035. CONCLUSIONS: Myocardial perfusion abnormalities are common in scorpion envenomation and correlate topographically with the contractile dysfunction. Recovery of contractility correlates with reversibility of perfusion defects. These findings suggest the participation of myocardial perfusion abnormalities in the pathophysiology of this form of acute ventricular failure. (Arq Bras Cardiol 2010;94(4: 418-425

  9. Valor prognóstico da cintilografia miocárdica de perfusão com tetrofosmin marcado com Tecnécio-99m sincronizada com o ciclo cardíaco (" Gated SPECT" na avaliação de pacientes com diabete melito e suspeita clínica de doença arterial coronariana Prognostic value of Tc-99m tetrofosmin myocardial perfusion gated SPECT in patients with diabetes mellitus and suspected coronary artery disease

    Directory of Open Access Journals (Sweden)

    Márcia Maria Sales dos Santos

    2008-01-01

    evaluated. Cardiac death, acute ischemic coronary syndrome, revascularization procedures or encephalic vascular accident were considered future cardiovascular events. The uni- and multivariate analyses were carried out by the multiple logistic regression model (p 3 (p=0.0001 and the number of altered segments > 3 (p=0.0001 were predictors of cardiovascular events. CONCLUSION: The myocardial scintigraphy with gated SPECT adds independent information to the stratification of the risk of future cardiovascular events in patients with DM and suspected coronary artery disease.

  10. Brain SPECT. SPECT in der Gehirndiagnostik

    Energy Technology Data Exchange (ETDEWEB)

    Feistel, H. (Erlangen-Nuernberg Univ., Erlangen (Germany). Nuklearmedizinische Klinik mit Poliklinik)

    1991-12-01

    Brain SPECT investigations have gained broad acceptance since the introduction of the lipophilic tracer Tc-99m-HMPAO. Depending on equipment and objectives in different departments, the examinations can be divided into three groups: 1. Under normal conditions and standardised patient preparation the 'rest' SPECT can be performed in every department with a tomographic camera. In cerebrovascular disease there is a demand for determination of either the perfusion reserve in reversible ischemia or prognostic values in completed stroke. In cases of dementia, SPECT may yield useful results according to differential diagnosis. Central cerebral system involvement in immunologic disease may be estimated with higher sensitivity than in conventional brain imaging procedures. In psychiatric diseases there is only a relative indication for brain SPECT, since results during recent years have been contradictory and may be derived only in interventional manner. In brain tumor diagnostics SPECT with Tl-201 possibly permits grading. In inflammatory disease, especially in viral encephalitis, SPECT may be used to obtain early diagnosis. Normal pressure hydrocephalus can be distinguished from other forms of dementia and, consequently, the necessity for shunting surgery can be recognised. 2. In departments equipped for emergency cases an 'acute' SPECT can be performed in illnesses with rapid changing symptoms such as different forms of migraine, transient global amnesia, epileptic seizures (so-called 'ictal SPECT') or urgent forms like trauma. 3. In cooperation with several departments brain SPECT can be practised as an interventional procedure in clinical and in scientific studies. (orig./MG).

  11. Very high coronary artery calcium score with normal myocardial perfusion SPECT imaging is associated with a moderate incidence of severe coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Yuoness, Salem A.; Goha, Ahmed M.; Romsa, Jonathan G.; Akincioglu, Cigdem; Warrington, James C.; Datta, Sudip; Gambhir, Sanjay; Urbain, Jean-Luc C.; Vezina, William C. [London Health Sciences Centre, Department of Nuclear Medicine, London, ON (Canada); Massel, David R. [London Health Sciences Centre, Division of Cardiology, London, ON (Canada); Martell, Rafael [Private Practice, London, ON (Canada)

    2015-09-15

    Myocardial perfusion imaging (MPI) has limitations in the presence of balanced multivessel disease (MVD) and left main (LM) coronary artery disease, occasionally resulting in false-normal results despite the high cardiovascular risk associated with this condition. The purpose of this study was to assess the incidence of severe coronary artery disease (CAD) in the presence of a very high Agatston coronary artery calcium (CAC) score (>1,000) in stable symptomatic patients without known CAD but with normal MPI results. A total of 2,659 prospectively acquired consecutive patients were referred for MPI and evaluation of CAC score by CT. Of this patient population, 8 % (222/2,659) had ischemia without myocardial infarction (MI) on MPI and 11 % (298/2,659) had abnormal MPI (MI and/or ischemia). On presentation 1 % of the patients (26/2,659) were symptomatic, had a CAC score >1,000 and normal MPI results. The definition of normal MPI was strict and included a normal hemodynamic response without ischemic ECG changes and normal imaging, particularly absence of transient ischemic dilation. All of these 26 patients with a CAC score >1,000 and normal MPI findings underwent cardiac catheterization. Of these 26 patients, 58 % (15/26) had severe disease (≥70 % stenosis) leading to revascularization. Of this group, 47 % (7/15) underwent percutaneous intervention, and 53 % (8/15) underwent coronary artery bypass grafting. All of these 15 patients had either MVD (14/15) or LM coronary artery disease (1/15), and represented 0.6 % (15/2,659) of all referred patients (95 % CI 0.3 - 0.9 %). The majority, 90 % (8/9), had severe CAD with typical chest pain. A very high CAC score (>1,000) with normal MPI in a small subset of symptomatically stable patients was associated with a moderate incidence of severe CAD (95 % CI 37 - 77 %). Larger studies and/or a meta-analysis of small studies are needed to more precisely estimate the incidence of CAD in this population. This study also supports

  12. SPECT in psychiatry. SPECT in der Psychiatrie

    Energy Technology Data Exchange (ETDEWEB)

    Barocka, A. (Psychiatrische Klinik und Poliklinik, Erlangen (Germany)); Feistel, H. (Nuklearmedizinische Klinik, Erlangen (Germany)); Ebert, D. (Psychiatrische Klinik und Poliklinik, Erlangen (Germany)); Lungershausen, E. (Psychiatrische Klinik und Poliklinik, Erlangen (Germany))

    1993-08-13

    This review presents Single Photon Emission Computed Tomography (SPECT) as a powerful tool for clinical use and research in psychiatry. Its focus is on regional cerebral blood flow, measured with technetium labelled HMPAO. In addition, first results with brain receptor imaging, concerning dopamin-D[sub 2] and benzodiazepine receptors, are covered. Due to major improvements in image quality, and impressive number of results has been accumulated in the past three years. The authors caution against using SPECT results as markers for disease entities. A finding like 'hypofrontality' is considered typical of a variety of mental disorders. Clearly both, more experience with SPECT and contributions from psychopathology, are needed. (orig.)

  13. Gated-SPECT myocardial perfusion imaging and coronary calcium score for evaluation of patients with acute chest pain and a normal or nondiagnostic electrocardiogram.

    Science.gov (United States)

    Peix, Amalia; Batista, Elida; Cabrera, Lázaro O; Rodríguez, Lydia; Padrón, Kenia; Saínz, Benito; Mendoza, Vladimir; Carrillo, Regla; Fernández, Yoel; Mena, Erick; Dondi, Maurizio

    2012-11-01

    To assess the ability of rest myocardial perfusion imaging (MPI) to rule out an acute coronary syndrome (ACS) in emergency department patients, as well as to investigate whether there exists a concordance between MPI and coronary calcium. Fifty-five patients with chest pain and a normal or nondiagnostic ECG were included. Clinical follow-up was carried out within 1 year. Sixteen patients (29%) showed an abnormal rest MPI, and in 11 (20%) the MPI was equivocal. There was a weak concordance between MPI and coronary arteries calcium score (CACS) (κ: 0.25). Coronary angiogram driven by a positive MPI was performed in 12 patients (23%), resulting in percutaneous coronary intervention in nine cases (75%). A positive MPI (abnormal or equivocal results) was associated with the occurrence of events in the follow-up (χ(2)=19.961, Ppatient presenting to the emergency department with acute chest pain and a normal or nondiagnostic ECG, with a positive MPI, the relative risk of having events during the first year was 7.5 (95% confidence interval: 2.8-19.2), Ppatients were free of events. Patients presenting with acute chest pain and a low-to-intermediate likelihood of coronary artery disease with a normal rest MPI have a very low probability of cardiac events during the first year. Coronary calcium score was not helpful in risk-stratifying these patients. © 2012 Wolters Kluwer Health | Lippincott Williams & Wilkins.

  14. Evaluation of exercise-induced myocardial stunning by means of immediate post-exercise Tc-{sup 99m} sestamibi gated SPECT; Evaluation de la sideration myocardique post-effort immediat par tomoscintigraphie myocardique au {sup 99m}Tc-sestamibi couplee a l'ECG

    Energy Technology Data Exchange (ETDEWEB)

    Ouvrier, M.J.; Hitzel, A.; Vera, P.; Manrique, A. [CRLCC Henri-Becquerel, CHU de Rouen, EA 4108, Dept. de Medecine Nucleaire, Lab. Litis, 76 - Rouen (France); Bernard, M. [CHU de Rouen, Service de Cardiologie, 76 - Rouen (France); Manrique, A. [GIP Cyceron, Service Commun Investigations chez l' Homme, Campus Jules-Horowitz, 14 - Caen (France)

    2009-06-15

    Aim: Repeated episodes of myocardial stunning may lead to chronic ventricular dysfunction. We attempted to assess the parameters related to post-exercise stunning in patients undergoing gated SPECT. Methods: Six hundred patients undergoing a one-day stress/rest {sup 99m}Tc-sestamibi gated SPECT were studied. Stress imaging was acquired within 15 minutes after injection. Summed perfusion scores (S.S.S., S.R.S. and S.D.S.) were calculated using Q.P.S., and L.V. function assessed using Q.G.S.. Stunning was defined as the association of ischemia (S.S.S. = 4 and SDS > 0) and a minimum of 5% decrease in post-stress E.F.. Results: Ischemia was found in 225 (37.5%) patients. Among these, 67 (30%) showed myocardial stunning. Patients with stunning had a lower rest E.S.V. (47 {+-} 24 ml vs 65 {+-} 52 ml, p < 0.0003) and E.D.V. (108{+-} 35 ml vs 122 {+-} 66 ml, p 0.03), an increased rest L.V.E.F. (58 {+-} 10% vs 52 {+-} 13%, p < 0.0001) and a decreased post-stress L.V.E.F. (49 {+-} 10% vs 53 {+-} 13%, p < 0.02) compared to patients with no stunning. The number of myocardial segments showing reversible perfusion defects was increased in patients with stunning (2.7 {+-} 2.6 vs 1.7 {+-} 2.1, p < 0.02). On logistic regression, an extent of ischemia greater than two segments and a rest E.F. greater than 45% were independent predictors of the occurrence of myocardial stunning in patients with ischemia. Conclusions: In patients with ischemia, exercise-induced stunning was associated with an increased extent of ischemia but also preserved rest ventricular function. (authors)

  15. Cell tracking and therapy evaluation of bone marrow monocytes and stromal cells using SPECT and CMR in a canine model of myocardial infarction

    Directory of Open Access Journals (Sweden)

    Merrifield Peter

    2009-04-01

    Full Text Available Abstract Background The clinical application of stem cell therapy for myocardial infarction will require the development of methods to monitor treatment and pre-clinical assessment in a large animal model, to determine its effectiveness and the optimum cell population, route of delivery, timing, and flow milieu. Objectives To establish a model for a in vivo tracking to monitor cell engraftment after autologous transplantation and b concurrent measurement of infarct evolution and remodeling. Methods We evaluated 22 dogs (8 sham controls, 7 treated with autologous bone marrow monocytes, and 7 with stromal cells using both imaging of 111Indium-tropolone labeled cells and late gadolinium enhancement CMR for up to12 weeks after a 3 hour coronary occlusion. Hearts were also examined using immunohistochemistry for capillary density and presence of PKH26 labeled cells. Results In vivo Indium imaging demonstrated an effective biological clearance half-life from the injection site of ~5 days. CMR demonstrated a pattern of progressive infarct shrinkage over 12 weeks, ranging from 67–88% of baseline values with monocytes producing a significant treatment effect. Relative infarct shrinkage was similar through to 6 weeks in all groups, following which the treatment effect was manifest. There was a trend towards an increase in capillary density with cell treatment. Conclusion This multi-modality approach will allow determination of the success and persistence of engraftment, and a correlation of this with infarct size shrinkage, regional function, and left ventricular remodeling. There were overall no major treatment effects with this particular model of transplantation immediately post-infarct.

  16. Is residual ischemia related to a worsening of the prognosis of patients treated with beta-blockers after myocardial infarction?; L'ischemie residuelle est-elle de mauvais pronostic chez les patients traites par beta-bloquant apres un infarctus myocardique,

    Energy Technology Data Exchange (ETDEWEB)

    Mercenier, C.; Hassan, N.; Grentzinger, A. [Centre Hospitalier Universitaire, 54 - Nancy (France)] [and others

    1999-11-01

    It has been demonstrated that myocardial ischemia, documented by exercise myocardial tomo-scintigraphy (MTS), was related to a worsening of prognosis. Our study was aimed at determining whether this deleterious effect persists in patients treated by beta-blockers, which are strong anti-anginal medications having a proven beneficial effect on prognosis. We have retrospectively included 300 patients (58{+-}11 years) treated by beta-blockers after myocardial infarction and for whom exercise thallium-201 MST had been performed on medical treatment. A myocardial ischemia was observed using MST in 224 patients (74%) and was extended on at least 15 % of the left ventricle in 86 patients (29%). During a follow-up period of 2.5{+-}1.4 years, only 22 patients had a major cardiac event (12 infarctions, 10 cardiac deaths). On Cox analysis of the MST parameters, the patients prognosis was correlated to the extent of necrotic myocardial areas (p < 0.001) but not to exercise ischemia. The annual rates of major events were 2% in the absence of ischemia, 2% when ischemia had a low extent (< 15 % of LV) and 3.5 % only when ischemia had a higher extent. Therefore, residual ischemia, detected after myocardial infarction by exercise MST, does not appear to have a deleterious prognosis effect when the patients are treated by beta-blockers. This might at least partly be related to the protective effect of beta-blockers against fatal cardiac arrhythmias which may be induced by ischemia. (author)

  17. 15-(ortho-123I-phenyl)-pentadecanoic acid, a new myocardial imaging agent for clinical use.

    Science.gov (United States)

    Antar, M A; Spohr, G; Herzog, H H; Kaiser, K P; Notohamiprodjo, G; Vester, E; Schwartzkopf, B; Lösse, B; Machulla, H J; Shreeve, W W

    1986-09-01

    The result of previous experiments in rodents indicated different kinetics for the para- and ortho-isomers of 15-(iodophenyl)-pentadecanoic acid (p-IPPA, o-IPPA), with o-IPPA showing an enhanced rate of washout. To test the relevance of this phenomenon for clinical diagnosis, 15 fasting male patients with confirmed coronary heart disease (1-VD/7, 2-VD/4, 3-VD/4) were investigated under exercise. Serial images were recorded at a rate of 3 frames min-1 for 70 to 90 min, corrected for tracer in blood and compared with thallium-201 images obtained from these patients within less than 2 weeks. Time-activity curves were also taken from the peripheral blood. Ortho-IPPA was well taken up by healthy myocardium and, contrary to rodents, retained with elimination half times longer than 200 min. A decreased myocardial uptake was seen which was very similar to the pattern obtained with thallium. Ortho-IPPA was eliminated from the blood to less than 10% at 4 min. Almost all radioactivity was in the organic phase (greater than 95% at 5 min) and chromatography showed only one major peak (o-IPPA) indicative of minimal organic catabolism.

  18. Radio-adaptive Response in Myocardial Perfusion Imaging Induced by Technetium-99m.

    Science.gov (United States)

    Shirazi, Mohammad Mehdi; Shabestani-Monfared, Ali; Shahidi, Maryam; Amiri, Mehrangiz; Abedi, Seyed Mohammad; Borzoueisileh, Sajad; Gorji, Kourosh Ebrahim Nejad

    2017-01-01

    Low dose radiation will induce adaptation and following exposure to an adaptive dose, the cells are more resistance to following challenging doses. This phenomenon is known as radio-adaptive response. The aim of this study was to investigate the percentage of apoptotic cells in the peripheral blood samples of the patients which undergo myocardial perfusion imaging (MPI) with technetium-99m (Tc-99m) before thallium scan to assess the induction of radio-adaptive response. In this study, 97 samples from 74 patients, referred to nuclear medicine center of Mazandaran Heart Hospital for MPI, which had no history of diagnostic, therapeutic, occupational, and radioactive exposures during past 2 years, were provided. The participants were classified into four groups including control, patients which were scanned solely with technetium, the patients which examined by thallium and the last group were the patients that examined by technetium followed by thallium. Then 2 ml Peripheral blood samples were obtained, and after 24 h incubating, the samples were studied by neutral comet assay. Statistical analysis was carried out using Student's t-test along with one-way analysis of variance. The mean percentage of apoptotic cells in the exposed groups were higher than the control. Furthermore, among exposed groups, the apoptotic cells in thallium group were more than others and this index was significantly lower in the group which was undergone technetium administration before thallium scan. These findings suggest that exposure to Tc-99m could induce a radio-adaptive response against the exposure of thallium-201.

  19. A combined static-dynamic single-dose imaging protocol to compare quantitative dynamic SPECT with static conventional SPECT.

    Science.gov (United States)

    Sciammarella, Maria; Shrestha, Uttam M; Seo, Youngho; Gullberg, Grant T; Botvinick, Elias H

    2017-08-03

    SPECT myocardial perfusion imaging (MPI) is a clinical mainstay that is typically performed with static imaging protocols and visually or semi-quantitatively assessed for perfusion defects based upon the relative intensity of myocardial regions. Dynamic cardiac SPECT presents a new imaging technique based on time-varying information of radiotracer distribution, which permits the evaluation of regional myocardial blood flow (MBF) and coronary flow reserve (CFR). In this work, a preliminary feasibility study was conducted in a small patient sample designed to implement a unique combined static-dynamic single-dose one-day visit imaging protocol to compare quantitative dynamic SPECT with static conventional SPECT for improving the diagnosis of coronary artery disease (CAD). Fifteen patients (11 males, four females, mean age 71 ± 9 years) were enrolled for a combined dynamic and static SPECT (Infinia Hawkeye 4, GE Healthcare) imaging protocol with a single dose of 99mTc-tetrofosmin administered at rest and a single dose administered at stress in a one-day visit. Out of 15 patients, eleven had selective coronary angiography (SCA), 8 within 6 months and the rest within 24 months of SPECT imaging, without intervening symptoms or interventions. The extent and severity of perfusion defects in each myocardial region was graded visually. Dynamically acquired data were also used to estimate the MBF and CFR. Both visually graded images and estimated CFR were tested against SCA as a reference to evaluate the validity of the methods. Overall, conventional static SPECT was normal in ten patients and abnormal in five patients, dynamic SPECT was normal in 12 patients and abnormal in three patients, and CFR from dynamic SPECT was normal in nine patients and abnormal in six patients. Among those 11 patients with SCA, conventional SPECT was normal in 5, 3 with documented CAD on SCA with an overall accuracy of 64%, sensitivity of 40% and specificity of 83%. Dynamic SPECT image

  20. Scintigraphic assessment of sympathetic innervation after transmural versus nontransmural myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Dae, M.W.; Herre, J.M.; O' Connell, J.W.; Botvinick, E.H.; Newman, D.; Munoz, L. (University of California, San Francisco (USA))

    1991-05-01

    To evaluate the feasibility of detecting denervated myocardium in the infarcted canine heart, the distribution of sympathetic nerve endings using I-123 metaiodobenzylguanidine (MIBG) was compared with the distribution of perfusion using thallium-201, with the aid of color-coded computer functional map in 16 dogs. Twelve dogs underwent myocardial infarction by injection of vinyl latex into the left anterior descending coronary artery (transmural myocardial infarction, n = 6), or ligation of the left anterior descending coronary artery (nontransmural myocardial infarction, n = 6). Four dogs served as sham-operated controls. Image patterns were compared with tissue norepinephrine content and with histofluorescence microscopic findings in biopsy specimens. Hearts with transmural infarction showed zones of absent MIBG and thallium, indicating scar. Adjacent and distal regions showed reduced MIBG but normal thallium uptake, indicating viable but denervated myocardium. Denervation distal to infarction was confirmed by reduced norepinephrine content and absence of nerve fluorescence. Nontransmural myocardial infarction showed zones of wall thinning with decreased thallium uptake and a greater reduction or absence of MIBG localized to the region of the infarct, with minimal extension of denervation beyond the infarct. Norepinephrine content was significantly reduced in the infarct zone, and nerve fluorescence was absent. These findings suggest that (1) MIBG imaging can detect viable and perfused but denervated myocardium after infarction; and (2) as opposed to the distal denervation produced by transmural infarction, nontransmural infarction may lead to regional ischemic damage of sympathetic nerves, but may spare subepicardial nerve trunks that course through the region of infarction to provide a source of innervation to distal areas of myocardium.

  1. Scintigraphic assessment of sympathetic innervation after transmural versus nontransmural myocardial infarction.

    Science.gov (United States)

    Dae, M W; Herre, J M; O'Connell, J W; Botvinick, E H; Newman, D; Munoz, L

    1991-05-01

    To evaluate the feasibility of detecting denervated myocardium in the infarcted canine heart, the distribution of sympathetic nerve endings using I-123 metaiodobenzylguanidine (MIBG) was compared with the distribution of perfusion using thallium-201, with the aid of color-coded computer functional map in 16 dogs. Twelve dogs underwent myocardial infarction by injection of vinyl latex into the left anterior descending coronary artery (transmural myocardial infarction, n = 6), or ligation of the left anterior descending coronary artery (nontransmural myocardial infarction, n = 6). Four dogs served as sham-operated controls. Image patterns were compared with tissue norepinephrine content and with histofluorescence microscopic findings in biopsy specimens. Hearts with transmural infarction showed zones of absent MIBG and thallium, indicating scar. Adjacent and distal regions showed reduced MIBG but normal thallium uptake, indicating viable but denervated myocardium. Denervation distal to infarction was confirmed by reduced norepinephrine content and absence of nerve fluorescence. Nontransmural myocardial infarction showed zones of wall thinning with decreased thallium uptake and a greater reduction or absence of MIBG localized to the region of the infarct, with minimal extension of denervation beyond the infarct. Norepinephrine content was significantly reduced in the infarct zone, and nerve fluorescence was absent. These findings suggest that 1) MIBG imaging can detect viable and perfused but denervated myocardium after infarction; and 2) as opposed to the distal denervation produced by transmural infarction, nontransmural infarction may lead to regional ischemic damage of sympathetic nerves, but may spare subepicardial nerve trunks that course through the region of infarction to provide a source of innervation to distal areas of myocardium.

  2. Investigation of dynamic SPECT measurements of the arterial input function in human subjects using simulation, phantom and human studies

    OpenAIRE

    Winant, Celeste D.; Aparici, Carina Mari; Zelnik, Yuval R.; Reutter, Bryan W.; Sitek, Arkadiusz; Bacharach, Stephen L.; Gullberg, Grant T

    2011-01-01

    Computer simulations, a phantom study and a human study were performed to determine whether a slowly rotating single-photon computed emission tomography (SPECT) system could provide accurate arterial input functions for quantification of myocardial perfusion imaging using kinetic models. The errors induced by data inconsistency associated with imaging with slow camera rotation during tracer injection were evaluated with an approach called SPECT/P (dynamic SPECT from positron emission tomograp...

  3. Comparison of non-attenuation corrected and attenuation corrected myocardial perfusion SPE

    Directory of Open Access Journals (Sweden)

    Hasan Raza

    2016-09-01

    Conclusion: This study demonstrates that CT based attenuation corrected Tc-99mm sestamibi SPECT myocardial perfusion imaging significantly improved the specificity of the RCA territory compared with non-attenuation corrected Tc-99mm sestamibi SPECT myocardial perfusion imaging in both genders irrespective of BMI.

  4. Availability of /sup 111/In-labeled platelet scintigraphy in patients with postinfarction left ventricular aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Tsuda, Takatoshi; Kubota, Masahiro; Iwakubo, Akifumi and others

    1989-03-01

    Eighteen patients with postinfarction left ventricular aneurysm (LVA) were examined with indium-111-labeled autologous platelet scintigraphy to identify intracardiac thrombi and to investigate the effect of antithrombotic agents on thrombogenesitiy within the LVA. Indium-111-platelet scintigraphy had a sensitivity of 60% and a specificity of 100% in detecting LVA mural thrombi. Among 6 patients showing false-negative scintigraphic studies, 4 was managed on antiplatelet therapy. Of 9 patients showing active platelet deposition on initial study, including 8 not receiving antiplatelet therapy, 5 were treated with tichlopidine (300 mg/day) for 29.8+-5.0 days. For the 5 patients, 2 had resolution and the 3 others had interruption of intraaneurysmal deposition in the second platelet study. For one patient receiving the third platelet study after warfarin therapy, it took two weeks to completely interrupt platelet deposition within the LVA. ECG gated radionuclide ventriculography and thallium-201 myocardial SPECT were also performed to assess left ventricular wall motion of left ventricular ejection fraction (LVEF) and myocardial blood perfusion. Thallium-201 SPECT showed apical or anteroapical perfusion defects. Radionuclide ventriculography pinpointed all 18 apical and anteroseptal aneurysms. A comparison between the thrombus positive group and the thrombus negative group revealed no statistical differences in LVEF and the period from the last myocardial infarction to the initial platelet scanning. These results suggest that indium-111 labeled platelet scintigraphy may be useful for identifying active left ventricular mural thrombi and for judging antiplatelet and anticoagulant therapy. (Namekawa, K).

  5. Specificity of the stress electrocardiogram during adenosine myocardial perfusion imaging in patients taking digoxin.

    Science.gov (United States)

    Hart, C Y; Miller, T D; Hodge, D O; Gibbons, R J

    2000-12-01

    In patients taking digoxin, the exercise electrocardiogram has a lower specificity for detecting coronary artery disease. However, the effect of digoxin on adenosine-induced ST-segment depression is unknown. The purpose of this study was to evaluate the specificity of the electrocardiogram during adenosine myocardial perfusion imaging in patients taking digoxin. Between May 1991 and September 1997, patients (n = 99) taking digoxin who underwent adenosine stress imaging with thallium-201 or technetium-99m sestamibi and coronary angiography within 3 months were retrospectively identified. Exclusion criteria included prior myocardial infarction, coronary artery angioplasty or bypass surgery, left bundle branch block, paced ventricular rhythm, or significant valvular disease. Twelve-lead electrocardiograms were visually interpreted at baseline, during adenosine infusion, and during the recovery period. The stress electrocardiogram was considered positive if there was > or =1 mm additional horizontal or downsloping ST-segment depression or elevation 0.08 seconds after the J-point compared with the baseline tracing. ST-segment depression and/or elevation occurred in 24 of 99 patients. There were only 2 false-positive stress electrocardiograms, yielding a specificity of 87% and positive predictive value of 92%. All 8 patients with > or =2 mm ST segment depression had multivessel disease by coronary angiography. ST-segment depression or elevation during adenosine myocardial perfusion imaging in patients taking digoxin is highly specific for coronary artery disease. Marked (> or =2 mm) ST-segment depression and/or ST-segment elevation is associated with a high likelihood of multivessel disease.

  6. Case of right ventricular infarction identified by sup(99m)Tc-PYP myocardial imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kawamura, Akiyoshi; Nakai, Kenji; Matsushita, Kazuo (Iwate Medical Coll., Morioka (Japan). School of Medicine)

    1982-06-01

    A case of 53-year-old-man with myocardial infarction accompanied by right ventricular infarction assessed by Tc-99m-PYP scintiscan was reported. Patient was admitted to our clinic because of sudden chest pain and Adames-Stokes attack. At the time of admission he was pre-shock state and cold sweating was markedly noted in the lower extremities. ECG revealed complete A-V block with ST elevation in II, III, aV sub(F). Chest X-ray film showed cardiomegaly and lung congestion. CVP was high (22 cm H/sub 2/O) and cardiac output was low (2.4 L/min). Marked elevation of SGOT, LDH and CPK was also noted. After administration of 20 mCi of Tc-99m-PYP, myocardial scintiscan revealed a positive accumulation, which continued for 80 days, in accordant with anterior portion of the right ventricle. From these findings, right ventricular infarction was clinicaly suspected. Combined therapy with dopamine (10 ..gamma../kg/min) and vasodilator and blood transfusion was effective in this patient. At the 60th day after admission, this patient had been recovered: Thallium-201 myocardial scintigraphy showed a perfusion defect in the inferior region. Total obstruction of RCA and diffuse stenosis of LAD were observed on CAG. Akinesis of inferoposterior region was found in the left ventriculogram. Tc-99m-PYP scintiscan in acute phase was a useful method in detecting of right ventricular infarction. Continued of positive accumulation of Tc-99m-PYP scintiscan suggested a possibility of aneurysmal formation of the right ventricle.

  7. Initial and delayed stress phase imaging in a single-injection double-acquisition SPECT. The potential value of early {sup 99m}Tc-MIBI redistribution in assessment of myocardial perfusion reversibility in patients with coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Beiki, D. [Research Inst. for Nuclear Medicine, Tehran Univ. of Medical Sciences, Tehran (Iran); Dept. of Nuclear Pharmacy, Tehran Univ. of Medical Sciences, Tehran (Iran); Fallahi, B.; Fard-Esfahani, A.; Eftekhari, M. [Research Inst. for Nuclear Medicine, Tehran Univ. of Medical Sciences, Tehran (Iran); Mohseni, Z.; Khalaj, A. [Dept. of Nuclear Pharmacy, Tehran Univ. of Medical Sciences, Tehran (Iran)

    2010-07-01

    Some studies reported that {sup 99m}Tc-MIBI may redistribute in ischaemic myocardium and this phenomenon may have potential role for better assessment of viability by delayed {sup 99m}Tc-MIBI imaging. Some studies also suggested that infusion of low dose dobutamine during delayed imaging may enhance the value of {sup 99m}Tc-MIBI imaging for evaluation of viability. The aim of this study is to determine whether the observed changes of perfusion defects on delayed images are caused by early radiotracer redistribution or as a result of reversal partial volume effect secondary to inotropic stimulation. Patients, methods: 89 patients with angiographically proven coronary artery disease (CAD) were enrolled in this randomized clinical trial study. In all cases, gated-SPECT images were obtained 60 minutes after stress with dipyridamole injection. Subsequently the patients were randomly allocated in two groups and the second imaging was performed at 120{sup th} minute during low dose dobutamine (dobutamine group; 45 cases) or placebo infusion (placebo group; 44 cases). Difference between summed stress score of the first (SSS{sub 1}) and second (SSS{sub 2}) stress images ({delta}SSS) was considered as a marker of reversibility in single-injection double-acquisition (SIDA) protocol. Also summed difference score (SDS) was recorded as a marker of reversibility in standard stress/rest, double-injection double-acquisition (DIDA) protocol. {delta}SSS of the two studied groups were compared. Also the correlation and agreement between {delta}SSS and SDS were analyzed. Results: A significant difference was found between SSS{sub 1} (median 15, range 0-48) and SSS{sub 2} (median 11, range 0-42) in total patients (p < 0.0001). A significant correlation was noted between {delta}SSS and SDS in dobutamine group (r = 0.58, p = 0.002) as well as in placebo group (r = 0.57, p < 0.0001). Considering DIDA protocol as a standard reference method, the influence of dobutamine infusion was not

  8. Iodine-123 phenylpentadecanoic acid myocardial scintigraphy in patients with left ventricular hypertrophy: Alterations in left ventricular distribution and utilization

    Energy Technology Data Exchange (ETDEWEB)

    Wolfe, C.L.; Kennedy, P.L.; Kulkarni, P.V.; Jansen, D.E.; Gabliani, G.I.; Corbett, J.R. (Univ. of Texas Health Science Center (USA))

    1990-06-01

    Regional alterations in myocardial substrate uptake and/or utilization have been demonstrated in rats with hypertension. To determine whether alterations in left ventricular fatty acid uptake and/or utilization are present in patients with left ventricular hypertrophy (LVH), we compared the results of rest and exercise iodine-123 phenylpentadecanoic acid (IPPA) myocardial scintigraphy in 10 patients with hypertension who had concentric LVH without evidence of coronary artery disease and in 15 normal subjects. Patients with LVH had more heterogeneous left ventricular activity of IPPA compared to normal subjects after exercise but not at rest. Although IPPA clearance was similar in both patients with LVH and normal subjects, postexercise washout in segments showing decreased initial IPPA uptake was reduced compared to washout at rest in patients with LVH (11.7 +/- 7.5% versus 21.5 +/- 8.4% at 20 minutes after injection, n = 15; p = 0.005). Exercise thallium-201 (TI-201) scintigraphy was normal in all seven patients with LVH tested. Patients with LVH showed significantly greater heterogeneity in IPPA uptake compared to TI-201 uptake immediately after exercise (25 +/- 5% versus 16 +/- 6%; p = 0.013). We conclude that (1) compared to normal subjects, patients with LVH show heterogeneous myocardial IPPA activity after exercise but not at rest; (2) postexercise washout of IPPA was decreased in segments with reduced uptake after exercise in patients with LVH; and (3) the distribution of IPPA is more heterogeneous than that of TI-201 immediately after exercise in patients with concentric LVH. The postexercise heterogeneity in IPPA uptake and delayed washout in segments with reduced initial uptake is consistent with exercise-induced myocardial ischemia in patients with LVH.

  9. Iodine-123 phenylpentadecanoic acid myocardial scintigraphy in patients with left ventricular hypertrophy: alterations in left ventricular distribution and utilization.

    Science.gov (United States)

    Wolfe, C L; Kennedy, P L; Kulkarni, P V; Jansen, D E; Gabliani, G I; Corbett, J R

    1990-06-01

    Regional alterations in myocardial substrate uptake and/or utilization have been demonstrated in rats with hypertension. To determine whether alterations in left ventricular fatty acid uptake and/or utilization are present in patients with left ventricular hypertrophy (LVH), we compared the results of rest and exercise iodine-123 phenylpentadecanoic acid (IPPA) myocardial scintigraphy in 10 patients with hypertension who had concentric LVH without evidence of coronary artery disease and in 15 normal subjects. Patients with LVH had more heterogeneous left ventricular activity of IPPA compared to normal subjects after exercise but not at rest (23 +/- 8% versus 13 +/- 5% difference in maximum segmental activity at 4 minutes after exercise; p = 0.005). Although IPPA clearance was similar in both patients with LVH and normal subjects, postexercise washout in segments showing decreased initial IPPA uptake was reduced compared to washout at rest in patients with LVH (11.7 +/- 7.5% versus 21.5 +/- 8.4% at 20 minutes after injection, n = 15; p = 0.005). Exercise thallium-201 (TI-201) scintigraphy was normal in all seven patients with LVH tested. Patients with LVH showed significantly greater heterogeneity in IPPA uptake compared to TI-201 uptake immediately after exercise (25 +/- 5% versus 16 +/- 6%; p = 0.013). We conclude that (1) compared to normal subjects, patients with LVH show heterogeneous myocardial IPPA activity after exercise but not at rest; (2) postexercise washout of IPPA was decreased in segments with reduced uptake after exercise in patients with LVH; and (3) the distribution of IPPA is more heterogeneous than that of TI-201 immediately after exercise in patients with concentric LVH. The postexercise heterogeneity in IPPA uptake and delayed washout in segments with reduced initial uptake is consistent with exercise-induced myocardial ischemia in patients with LVH.

  10. Myocardial perfusion defects and the left ventricular ejection fraction disclosed by scintigraphy in patients with primary hyperparathyroidism

    DEFF Research Database (Denmark)

    Ogard, Christina Gerlach; Søndergaard, Susanne Bonnichsen; Vestergaard, Henrik

    2005-01-01

    Patients with primary hyperparathyroidism (PHPT) have increased risk of cardiovascular disease. For patients undergoing preoperative parathyroid imaging with 99mTc-sestamibi single photon emission computed tomography (SPECT), we combined cervical SPECT and gated cardiac SPECT to achieve information...... about the localization of parathyroid adenomas, myocardial perfusion, and the left ventricular ejection fraction (LVEF) at rest. A series of 22 patients with PHPT and no history of myocardial infarction or angina pectoris were recruited consecutively. At 60 minutes after injection of 700 MBq 99m......Tc-sestamibi, SPECT of the neck and gated myocardial perfusion SPECT were performed at the same time. All of the patients who underwent parathyroidectomy had the parathyroid adenoma localized as predicted from the SPECT. Five patients (23%) had myocardial perfusion defects extending more than 15% (range 15...

  11. SPECT in epilepsies; SPECT bei Epilepsien

    Energy Technology Data Exchange (ETDEWEB)

    Stefan, H. [Neurologische Klinik, Univ. Erlangen-Nuernberg, Zentrum Epilepsie Erlangen (Germany)

    1997-06-01

    Registration of regional cerebral blood flow provides important new data for the investigation of pathophysiological processes in epilepsies. Further to the registration of perfusions, receptor studies are employed for the differentiation of localisation in focal epilepsies. For ultimative issues interictal registrations are supplemented by ictal recordings during the epileptic seizure. The combination of SPECT and electrophysiological registration can contribute to analysis of propagation of focal epileptic activity. (orig.) [Deutsch] Die Messung der regionalen Hirndurchblutung liefert wichtige neue Erkenntnis zur Untersuchung pathophysiologischer Ablaeufe bei Epilepsien. Ergaenzend zur Registrierung der Perfusion koennen Rezeptor-Studien zur Differenzierung der Lokalisation fokaler Epilepsien beitragen. Interiktale Registrierungen werden fuer letztere Fragestellung durch iktuale Messungen waehrend des epileptischen Anfalls ergaenzt. Die Kombination von SPECT und elektrophysiologischen Registrierungen kann zur Analyse der Propagation fokaler epileptischer Aktivitaet beitragen. (orig.)

  12. Applications of cerebral SPECT

    Energy Technology Data Exchange (ETDEWEB)

    McArthur, C., E-mail: claire.mcarthur@nhs.net [Department of Neuroradiology, Institute of Neurological Sciences, Glasgow (United Kingdom); Jampana, R.; Patterson, J.; Hadley, D. [Department of Neuroradiology, Institute of Neurological Sciences, Glasgow (United Kingdom)

    2011-07-15

    Single-photon emission computed tomography (SPECT) can provide three-dimensional functional images of the brain following the injection of one of a series of radiopharmaceuticals that crosses the blood-brain barrier and distributes according to cerebral perfusion, neurotransmitter, or cell density. Applications include differentiating between the dementias, evaluating cerebrovascular disease, preoperative localization of epileptogenic foci, diagnosing movement disorders, and evaluation of intracerebral tumours, while also proving a useful research tool. Unlike positronemission tomography (PET), SPECT imaging is widely available and can be performed in any department that has access to a rotating gamma camera. The purpose of this review is to demonstrate the utility of cerebral SPECT and increase awareness of its role in the investigation of neurological and psychiatric disorders.

  13. The limited role of myocardial fluorine-18 fluorodeoxyglucose imaging in candidates for cardiac transplantation. A planar imaging study

    Energy Technology Data Exchange (ETDEWEB)

    Kalff, V.; Van Every, B.; Kelly, M.J. [Alfred Hospital, Prahran, VIC (Australia). Dept. of Nuclear Medicine; Barton, H.J.; Bergin, P.J.; Esmore, D.S. [Alfred Hospital, Prahran, VIC (Australia). Cardiac Transplantation Services; Berlangieri, S.U. [Austin Hospital, Heidelberg, VIC (Australia). Centre for Positron Emission Tomography

    1998-03-01

    This study compares the incidence and extent of hibernating myocardium (defined by myocardial perfusion/metabolism mismatch) in 28 cardiac transplant candidates with ischaemic cardiomyopathy and in 16 other patients with coronary artery disease (CAD) undergoing viability assessment. It then reviews the impact of myocardial perfusion metabolism imaging on management decisions in the transplant candidates at 6 months after scintigraphy. Each patient underwent a planar myocardial thallium-201 and fluorine-18 fluorodeoxyglucose scan on a modified gamma camera. Perfusion/metabolism mismatch was sized semi-quantitatively and each patient was assigned a global mismatch score. Transplant candidates had a lower left ventricular ejection fraction (LVEF) (P<0.0002) and extent of hibernating myocardium (lower global mismatch score: P=0.005) than other CAD patients but the difference in respect of mismatch frequency (8/28 vs 9/16 patients) did not reach statistical significance. Transplant candidates with LVEF <20% had a lower global mismatch score (P<0.02) than those with an LVEF {>=}20%. Interestingly, two of three other CAD patients with LVEF <20% had a moderate mismatch. Follow-up studies revealed the lack of impact of metabolic imaging as none of the three transplant candidates who eventually underwent revascularisation had hibernating myocardium and transplantation was offered to one of only two candidates with more than one minor mismatch. Thus metabolic imaging in potential transplant candidates may be of limited value because of the very low extent of hibernating myocardium, particularly if LVEF is below 20% and where clinical decisions are often based on many other factors. (orig.)

  14. Longitudinal in vivo SPECT/CT imaging reveals morphological changes and cardiopulmonary apoptosis in a rodent model of pulmonary arterial hypertension.

    Science.gov (United States)

    Paffett, Michael L; Hesterman, Jacob; Candelaria, Gabriel; Lucas, Selita; Anderson, Tamara; Irwin, Daniel; Hoppin, Jack; Norenberg, Jeffrey; Campen, Matthew J

    2012-01-01

    Pulmonary arterial hypertension (PAH) has a complex pathogenesis involving both heart and lungs. Animal models can reflect aspects of the human pathology and provide insights into the development and underlying mechanisms of disease. Because of the variability of most animal models of PAH, serial in vivo measurements of cardiopulmonary function, morphology, and markers of pathology can enhance the value of such studies. Therefore, quantitative in vivo SPECT/CT imaging was performed to assess cardiac function, morphology and cardiac perfusion utilizing (201)Thallium ((201)Tl) in control and monocrotaline-treated rats. In addition, lung and heart apoptosis was examined with (99m)Tc-Annexin V ((99m)Tc-Annexin) in these cohorts. Following baseline imaging, rats were injected with saline or monocrotaline (50 mg/kg, i.p.) and imaged weekly for 6 weeks. To assess a therapeutic response in an established pulmonary hypertensive state, a cohort of rats received resveratrol in drinking water (3 mg/kg/day) on days 28-42 post-monocrotaline injection to monitor regression of cardiopulmonary apoptosis. PAH in monocrotaline-treated rats was verified by conventional hemodynamic techniques on day 42 (right ventricular systolic pressure (RSVP) = 66.2 mmHg in monocrotaline vs 28.8 mmHg in controls) and in terms of right ventricular hypertrophy (RV/LVS = 0.70 in monocrotaline vs 0.32 in controls). Resveratrol partially reversed both RVSP (41.4 mmHg) and RV/LVS (0.46), as well as lung edema and RV contractility +dP/dt(max). Serial (99m)Tc-Annexin V imaging showed clear increases in pulmonary and cardiac apoptosis when compared to baseline, which regressed following resveratrol treatment. Monocrotaline induced modest changes in whole-heart perfusion as assessed by (201)TI imaging and cardiac morphological changes consistent with septal deviation and enlarged RV. This study demonstrates the utility of functional in vivo SPECT/CT imaging in rodent models of PAH and further confirms

  15. Radiotracers for SPECT imaging. Current scenario and future prospects

    Energy Technology Data Exchange (ETDEWEB)

    Adak, S.; Vijaya Raj, K.K.; Mandal, S. [GE Healthcare Medical Diagnostics, John F. Welch Technology Center, Bangalore (India).; Bhalla, R.; Pickett, R.; Luthra, S.K. [GE Healthcare Medical Diagnostics, The Grove Centre, Amersham (United Kingdom)

    2012-07-01

    Single photon emission computed tomography (SPECT) has been the cornerstone of nuclear medicine and today it is widely used to detect molecular changes in cardiovascular, neurological and oncological diseases. While SPECT has been available since the 1980s, advances in instrumentation hardware, software and the availability of new radiotracers that are creating a revival in SPECT imaging are reviewed in this paper. The biggest change in the last decade has been the fusion of CT with SPECT, which has improved attenuation correction and image quality. Advances in collimator design, replacement of sodium iodide crystals in the detectors with cadmium zinc telluride (CZT) detectors as well as advances in software and reconstruction algorithms have all helped to retain SPECT as a much needed and used technology. Today, a wide spectrum of radiotracers is available for use in cardiovascular, neurology and oncology applications. The development of several radiotracers for neurological disorders is briefly described in this review, including [{sup 123}I]FP-CIT (DaTSCAN trademark) available for Parkinson's disease. In cardiology, while technetium-99m labeled tetrofosmin and technetium-99m labeled sestamibi have been well known for myocardial perfusion imaging, we describe a recently completed multicenter clinical study on the use of [{sup 123}I]mIBG (AdreView trademark) for imaging in chronic heart failure patients. For oncology, while bone scanning has been prevalent, newer radiotracers that target cancer mechanisms are being developed. Technetium-99m labeled RGD peptides have been reported in the literature that can be used for imaging angiogenesis, while technetium-99m labeled duramycin has been used to image apoptosis. While PET/CT is considered to be the more advanced technology particularly for oncology applications, SPECT continues to be the modality of choice and the workhorse in many hospitals and nuclear medicine centers. The cost of SPECT instruments also

  16. Nuclear medicine and coronary artery disease: evaluation of tracers of myocardial perfusion and vulnerable atherosclerotic plaque; Medecine nucleaire et maladie coronarienne: evaluation de traceurs de la perfusion myocardique et de la plaque d'atherome vulnerable

    Energy Technology Data Exchange (ETDEWEB)

    Broisat, A

    2005-04-15

    Coronary artery disease is one of the primary cause of mortality worldwide. Nuclear medicine is the major imaging technique for diagnosis and following of this disease. perfusion: nowadays, major radioactive agents used in clinical practice are myocardial perfusion tracers. The reference tracer is thallium-201. However, {sup 201}Tl presents some drawbacks. {sup 99m}Tcn-noet has been proposed for its replacement. This study shows that in contrast with previous studies realized in vitro on cardio myocytes, verapamil, an l-type calcium channel inhibitor, does not inhibit myocardial fixation of {sup 99m}Tcn-noet in vivo in dog. This data is in agreement with the hypothesis of a non specific endothelial fixation of this tracer. Moreover, this study shows that as a pure tracer of myocardial perfusion, {sup 99m}Tcn-noet can also be used to assess myocardial viability on a model of myocardial chronic infarction in rat. atherosclerosis: disruption of vulnerable atherosclerotic plaques is the main event leading to coronary accidents. The second part of this study concerns the evaluation of new potential tracers of the vulnerable atherosclerotic plaque in an experimental model of rabbit with an inheritable hypercholesterolemia. The four tracers evaluated (b2702(r), b2702-I, b2702-Tc and Tc-raft-b2702) are synthetic peptides comprising the residues 75-84 of hla-b2702, a molecule known to link vcam-1, an adhesion molecule expressed in vulnerable atherosclerotic plaque. The autoradiography studies show that all tracers accumulate within atherosclerotic plaque expressing vcam- and that. i-b2702 shows the best plaque/control fixation ratio. (author)

  17. Spect in epilepsy; SPECT bei Anfallsleiden

    Energy Technology Data Exchange (ETDEWEB)

    Feistel, H. [Nuklearmedizinische Klinik mit Poliklinik und Neurologische Klinik, Friedrich-Alexander-Univ. Erlangen-Nuernberg, Erlangen (Germany); Weis, M. [Nuklearmedizinische Klinik mit Poliklinik und Neurologische Klinik, Friedrich-Alexander-Univ. Erlangen-Nuernberg, Erlangen (Germany); Michalik, K. [Nuklearmedizinische Klinik mit Poliklinik und Neurologische Klinik, Friedrich-Alexander-Univ. Erlangen-Nuernberg, Erlangen (Germany); Schueler, P. [Nuklearmedizinische Klinik mit Poliklinik und Neurologische Klinik, Friedrich-Alexander-Univ. Erlangen-Nuernberg, Erlangen (Germany); Platsch, G. [Nuklearmedizinische Klinik mit Poliklinik und Neurologische Klinik, Friedrich-Alexander-Univ. Erlangen-Nuernberg, Erlangen (Germany); Stefan, H. [Nuklearmedizinische Klinik mit Poliklinik und Neurologische Klinik, Friedrich-Alexander-Univ. Erlangen-Nuernberg, Erlangen (Germany); Wolf, F. [Nuklearmedizinische Klinik mit Poliklinik und Neurologische Klinik, Friedrich-Alexander-Univ. Erlangen-Nuernberg, Erlangen (Germany)

    1997-06-01

    In the Federal Republic of Germany it is assumed that about 80 000 patients suffer from a focal form of epilepsy which can not be sufficiently controlled with medication. As potential candidates for surgery, these patients undergo stepwise monitoring procedure in which the epileptic focus is located by means of increasingly invasive methods. In Erlangen the periictal SPECT is performed, whereby the perfusion tracer is injected after onset (ictal SPECT), immediately after cessation of the seizure (postictal scan) or between the seizures (interictal scan). To administer the tracer strongly in ictal or postictal state a close functional cooperation between the neurology and nuclear medicine department must be arranged. Injection inside the monitoring unit must be attuned to federal antiradiation precaution law. In temporal lobe epilepsy, different injection-times demonstrate a large area of hyperperfusion after ictal onset, which refines in the first two postictal minutes to the generating focus together with a decreased parietal blood flow pattern. Later, the entire temporal lobe epilepsy an early tracer injection within 40 seconds has to be achieved, otherwise an ictal propagation into distant brain areas, possibly contralateral, may occur. Extratemporal epilepsy is often linked to trauma or congenital malformations, and is difficult to categorize. In difficult cases with equivocal results, efforts can be undertaken by means of receptor scintigraphy with, for example, iomazenil, to localize the focus as a cold lesion caused by neuronal loss. (orig.) [Deutsch] In der Bundesrepublik Deutschland leiden nach vorsichtigen Schaetzungen ca. 80 000 Patienten an einer fokalen Epilepsieform, die mit Medikamenten nur unzureichend kontrolliert werden kann. Als potentielle Kandidaten fuer einen epilepsiechirurgischen Eingriff werden sie einem intensiven Monitoringverfahren unterzogen, in dem stufenweise nach dem Grad der Invasivitaet gesteigert, verschiedene Moeglichkeiten zu

  18. FDG-SPECT and hibernation: an interim review; {sup 18}Fluor-FDG-SPECT zum Nachweis von hibernierendem Myokard: eine Zwischenbilanz

    Energy Technology Data Exchange (ETDEWEB)

    Alexander, C. [Universitaetskliniken des Saarlandes, Homburg (Germany). Abt. fuer Nuklearmedizin; Schaefer, A. [Universitaetskliniken des Saarlandes, Homburg (Germany). Abt. fuer Nuklearmedizin; Trampert, L. [Universitaetskliniken des Saarlandes, Homburg (Germany). Abt. fuer Nuklearmedizin; Oberhausen, E. [Universitaetskliniken des Saarlandes, Homburg (Germany). Abt. fuer Nuklearmedizin; Kirsch, C.M. [Universitaetskliniken des Saarlandes, Homburg (Germany). Abt. fuer Nuklearmedizin; Berberich, R. [Universitaetskliniken des Saarlandes, Homburg (Germany). Abt. fuer Nuklearmedizin

    1997-06-01

    Aim: The present investigation demonstrates an intraindividual comparison of FDG-PET and FDG-SPECT. Material and Methods: Thirty patients with CHD and planed revascularisation underwent both modalities. Myocardial perfusion was evaluated by {sup 99m}Tc-MIBI SPECT. The myocardium was divided into 25 segments and the results were compared by two experienced observers. Results: Segmental concordance of FDG-PET and -SPECT was 94.1%. PET indicated a higher percentage of hibernating myocardium (8.9% vs. 5.7%) and a lower rate of matched defects (11.5% vs. 16.0%). In 22 cases the need for revascularisation was assessed identically. In the remaining 8 patients FDG-PET and FDG-SPECT required an intervention in 6 and 2 cases, respectively. Conclusion: The results of FDG-PET and FDG-SPECT showed a high segmental concordance, but the individual assessment of hibernation worthwhile for revascularisation demonstrated important differences in patient management. (orig.) [Deutsch] Ziel der vorliegenden Arbeit war ein intraindividueller Vergleich von FDG-PET und FDG-SPECT in der myokardialen Vitalitaetsdiagnostik. Material und Methodik: Bei 30 Patienten mit KHK wurden vor Revaskularisation beide Verfahren durchgefuehrt. Die Beurteilung der myokardialen Perfusion erfolgte mittels {sup 99m}Tc-MIBI SPECT. Die Resultate wurden von zwei erfahrenen Auswertern unter Verwendung einer 25-Segment-Einteilung des Myokards verglichen. Ergebnisse: Die segmentale Uebereinstimmung zwischen PET und SPECT betrug 94,1%. Die PET wies einen hoeheren Anteil hibernierendes Myokard aus (8,9% vs. 5,7%) und weniger Narbensegmente (11,5% bs. 16,0%). Die Indikation zur Revaskularisation wurde in 22 Faellen identisch beurteilt. Bei den uebrigen 8 Untersuchungen sprach sechsmal die PET und zweimal die SPECT fuer eine Intervention. Schlussfolgerung: Einer hohen segmentalen Uebereinstimmung stehen also erhebliche Unterschiede in der letztendlich entscheidenden klinischen Beurteilung der Untersuchungsergebnisse

  19. SU-C-201-04: Quantification of Perfusion Heterogeneity Based On Texture Analysis for Fully Automatic Detection of Ischemic Deficits From Myocardial Perfusion Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Fang, Y [National Cheng Kung University, Tainan, Taiwan (China); Huang, H [Chang Gung University, Taoyuan, Taiwan (China); Su, T [Chang Gung Memorial Hospital, Taoyuan, Taiwan (China)

    2015-06-15

    Purpose: Texture-based quantification of image heterogeneity has been a popular topic for imaging studies in recent years. As previous studies mainly focus on oncological applications, we report our recent efforts of applying such techniques on cardiac perfusion imaging. A fully automated procedure has been developed to perform texture analysis for measuring the image heterogeneity. Clinical data were used to evaluate the preliminary performance of such methods. Methods: Myocardial perfusion images of Thallium-201 scans were collected from 293 patients with suspected coronary artery disease. Each subject underwent a Tl-201 scan and a percutaneous coronary intervention (PCI) within three months. The PCI Result was used as the gold standard of coronary ischemia of more than 70% stenosis. Each Tl-201 scan was spatially normalized to an image template for fully automatic segmentation of the LV. The segmented voxel intensities were then carried into the texture analysis with our open-source software Chang Gung Image Texture Analysis toolbox (CGITA). To evaluate the clinical performance of the image heterogeneity for detecting the coronary stenosis, receiver operating characteristic (ROC) analysis was used to compute the overall accuracy, sensitivity and specificity as well as the area under curve (AUC). Those indices were compared to those obtained from the commercially available semi-automatic software QPS. Results: With the fully automatic procedure to quantify heterogeneity from Tl-201 scans, we were able to achieve a good discrimination with good accuracy (74%), sensitivity (73%), specificity (77%) and AUC of 0.82. Such performance is similar to those obtained from the semi-automatic QPS software that gives a sensitivity of 71% and specificity of 77%. Conclusion: Based on fully automatic procedures of data processing, our preliminary data indicate that the image heterogeneity of myocardial perfusion imaging can provide useful information for automatic determination

  20. Myocardial Bridge

    Science.gov (United States)

    ... Sudden Cardiac Arrest Valve Disease Vulnerable Plaque Myocardial Bridge Related terms: myocardium, coronary arteries, myocardial ischemia Your ... surface of the heart. What is a myocardial bridge? A myocardial bridge is a band of heart ...

  1. Innovative reconstruction algorithms in cardiac SPECT scintigraphy.

    Science.gov (United States)

    Zoccarato, O

    2012-06-01

    The recent entry into the market of some advanced iterative reconstruction algorithms (IA) optimized for bone and cardiac studies has raised a great interest among specialists in nuclear medicine. In particular, myocardial perfusion studies have received a significant boost thanks to the superior quality of images obtained with these new reconstruction methods. Differently from the filtered back-projection (FBP), the basic principles of the iterative reconstruction techniques are less known; unclear is the way by which the iterative methods are able to include compensations for the main degradation phenomena in SPECT imaging. Aim of this review is to provide a simple introduction to the iterative solution of the tomographic problem by using its matricial representation. This paper will also provide simple graphical examples of how phenomena such as attenuation and depth dependent resolution can be modelled in the projection operator. The main degrading factors in cardiac SPECT images will be retrieved along with some indication of the effectiveness of the corrections adopted. This step makes clear the noteworthy qualitative improvement obtained with these advanced algorithms. A brief summary of the main features of the most widespread new iterative reconstruction algorithms will be presented. The majority of manufacturers emphasize the reduction of acquisition times allowed by these innovative algorithms. Finally, because of the awareness of the increasing exposure of the population due to the increasing number of imaging studies with ionizing radiation, the use of these advanced algorithms to achieve a simultaneous reduction in patient dose and acquisition time will be also shown.

  2. Novel SPECT Technologies and Approaches in Cardiac Imaging

    Directory of Open Access Journals (Sweden)

    Piotr Slomka

    2016-12-01

    Full Text Available Recent novel approaches in myocardial perfusion single photon emission CT (SPECT have been facilitated by new dedicated high-efficiency hardware with solid-state detectors and optimized collimators. New protocols include very low-dose (1 mSv stress-only, two-position imaging to mitigate attenuation artifacts, and simultaneous dual-isotope imaging. Attenuation correction can be performed by specialized low-dose systems or by previously obtained CT coronary calcium scans. Hybrid protocols using CT angiography have been proposed. Image quality improvements have been demonstrated by novel reconstructions and motion correction. Fast SPECT acquisition facilitates dynamic flow and early function measurements. Image processing algorithms have become automated with virtually unsupervised extraction of quantitative imaging variables. This automation facilitates integration with clinical variables derived by machine learning to predict patient outcome or diagnosis. In this review, we describe new imaging protocols made possible by the new hardware developments. We also discuss several novel software approaches for the quantification and interpretation of myocardial perfusion SPECT scans.

  3. Quantitative evaluation of myocardial function by a volume-normalized map generated from relative blood flow

    Energy Technology Data Exchange (ETDEWEB)

    Fukami, Tadanori [Department of Bio-system Engineering, Faculty of Engineering, Yamagata University, Yonezawa, Yamagata 992-8510 (Japan); Sato, Hidenori [Department of Bio-system Engineering, Faculty of Engineering, Yamagata University, Yonezawa, Yamagata 992-8510 (Japan); Wu, Jin [Graduate School of Comprehensive Human Sciences, University of Tsukuba, Ibaraki 305-8575 (Japan); Lwin, Thet-Thet- [Graduate School of Comprehensive Human Sciences, University of Tsukuba, Ibaraki 305-8575 (Japan); Yuasa, Tetsuya [Department of Bio-system Engineering, Faculty of Engineering, Yamagata University, Yonezawa, Yamagata 992-8510 (Japan); Kawano, Satoru [Graduate School of Comprehensive Human Sciences, University of Tsukuba, Ibaraki 305-8575 (Japan); Iida, Keiji [Graduate School of Comprehensive Human Sciences, University of Tsukuba, Ibaraki 305-8575 (Japan); Akatsuka, Takao [Department of Bio-system Engineering, Faculty of Engineering, Yamagata University, Yonezawa, Yamagata 992-8510 (Japan); Hontani, Hidekata [Department of Computer Science and Engineering, Nagoya Institute of Technology, Aichi 466-8555 (Japan); Takeda, Tohoru [Graduate School of Comprehensive Human Sciences, University of Tsukuba, Ibaraki 305-8575 (Japan); Tamura, Masao [Graduate School of Comprehensive Human Sciences, University of Tsukuba, Ibaraki 305-8575 (Japan); Yokota, Hiroshi [Graduate School of Comprehensive Human Sciences, University of Tsukuba, Ibaraki 305-8575 (Japan)

    2007-07-21

    Our study aimed to quantitatively evaluate blood flow in the left ventricle (LV) of apical hypertrophic cardiomyopathy (APH) by combining wall thickness obtained from cardiac magnetic resonance imaging (MRI) and myocardial perfusion from single-photon emission computed tomography (SPECT). In this study, we considered paired MRI and myocardial perfusion SPECT from ten patients with APH and ten normals. Myocardial walls were detected using a level set method, and blood flow per unit myocardial volume was calculated using 3D surface-based registration between the MRI and SPECT images. We defined relative blood flow based on the maximum in the whole myocardial region. Accuracies of wall detection and registration were around 2.50 mm and 2.95 mm, respectively. We finally created a bull's-eye map to evaluate wall thickness, blood flow (cardiac perfusion) and blood flow per unit myocardial volume. In patients with APH, their wall thicknesses were over 10 mm. Decreased blood flow per unit myocardial volume was detected in the cardiac apex by calculation using wall thickness from MRI and blood flow from SPECT. The relative unit blood flow of the APH group was 1/7 times that of the normals in the apex. This normalization by myocardial volume distinguishes cases of APH whose SPECT images resemble the distributions of normal cases.

  4. Single photon emission computed tomography of technetium-99m tetrofosmin myocardial perfusion imaging in patients with systemic lupus erythematosus-A preliminary report

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Jen-Jhy; Hsu, Hsiu-Bao; Sun, Shung-Shung; Kao, Chia-Hung [China Medical Coll., Taichung, Taiwan (China). Hospital; Wang, Jhi-Joung [Chi-Mei Medical Center, Tainan, Taiwan (China); Ho, Shung-Tai [National Defense Medical Center, Taipei, Taiwan (China). School of Medicine

    2003-01-01

    The purpose of this study was to evaluate the utility of single-photon emission computed tomography (SPECT) of technetium-99m tetrofosmin (Tc-99m TF) myocardial perfusion imaging to detect myocardial involvement in patients with systemic lupus erythematosus (SLE). Three groups of subjects-group 1: 25 SLE female patients with non-specific cardiac symptoms and signs, group 2: 25 female SLE patients without any cardiac symptoms and signs, and group 3: 25 female healthy controls-were evaluated by comparing rest and dipyridamole-stress Tc-99m TF myocardial perfusion SPECT. Tc-99m TF myocardial perfusion SPECT revealed perfusion defects in 88% and 40% of the cases in groups 1 and 2, respectively. However, no cases in group 3 demonstrated myocardial perfusion defects. Tc-99m TF myocardial perfusion SPECT is a useful noninvasive imaging modality to detect cardiac involvement in SLE patients with or without cardiac symptoms and signs. (author)

  5. Feasibility and safety of exercise stress testing using an anti-gravity treadmill with Tc-99m tetrofosmin single-photon emission computed tomography (SPECT) myocardial perfusion imaging: A pilot non-randomized controlled study.

    Science.gov (United States)

    Daly, Patrick; Kayse, Regina; Rudick, Steven; Robbins, Nathan; Scheler, Jennifer; Harris, David; O'Donnell, Robert; Dwivedi, Alok K; Gerson, Myron C

    2017-08-31

    Exercise is the AHA/ACC guideline-recommended stress modality for myocardial perfusion imaging, but many patients are unable to exercise to target heart rate on a conventional treadmill. We examined the feasibility and safety of stress imaging using an anti-gravity treadmill in patients with perceived poor exercise capacity. 49 patients were recruited for stress testing by anti-gravity treadmill (n = 29) or to a regadenoson control group (n = 20). Seventeen anti-gravity test patients (59%) reached target heart rate obviating the need for a pharmacologic stress agent. Adverse effects of the anti-gravity treadmill were limited to minor muscle aches in 5 subjects. Stress myocardial perfusion image quality judged by 3 blinded readers on a 5-point scale was comparable for the anti-gravity treadmill (4.30 ± SD 0.87) vs pharmacologic stress (4.28 ± SD 0.66). Stress testing using an anti-gravity treadmill is feasible and may help some patients safely achieve target heart rate.

  6. Quantitation in Dextrocardia on myocardial perfusion imaging: how to perform quantitative analysis using Cedars-Sinai software.

    Science.gov (United States)

    Qutbi, Mohsen; Soltanshahi, Mehdi; Ansari, Mojtaba; Hashemi, Hoda; Neshandar Asli, Isa; Shafiei, Babak

    2018-01-01

    Dextrocardia, although a rare cardiac abnormality, carries the same risk for cardiac events as other people. SPECT Myocardial perfusion imaging is a potentially helpful diagnostic tool in patients with dextrocardia. Because of swapping of lateral and septal walls on SPECT slices, although visual analysis is possible, quantitation is substantially limited. Here, we introduce a simple practical method to make quantitative analysis feasible and accurate.

  7. The efficacy of nisoldipine on myocardial perfusion in patients with silent myocardial ischemia

    Energy Technology Data Exchange (ETDEWEB)

    Yamazaki, Junichi; Muto, Hiroshi; Naitou, Katsutoshi [Toho University, Tokyo (Japan). Omori Hospital] [and others

    1997-06-01

    Patients who had old myocardial infarction associated with myocardial viability and ischemia were divided into a pain-free group and a pain-positive group of nine patients each. The improvement of myocardial perfusion with nisoldipine therapy was compared between the two groups using exercise-load Tl-201 myocardial SPECT (myocardial SPECT). The exercise time was significantly prolonged from 505 seconds to 607 seconds after administration of nisoldipine in the pain-positive group (p<0.05), but there was no change in the pain-free group. The extent score of the full circumference of the left ventricle, the severity score, and the %Tl uptake of the infarcted region were significantly improved in both groups by administration of nisoldipine. These findings suggested that nisoldipine caused a decrease in the myocardial oxygen requirements associated with reduction of the afterload and coronary artery dilatation in the pain-positive group, but mainly caused coronary dilatation in the pain-free group. Since myocardial perfusion also improved after nisoldipine administration in the pain-free group, the possibility that calcium antagonists can be used for prophylactic treatment of asymptomatic myocardial ischemia was suggested. (author)

  8. ACCF/ASNC appropriateness criteria for single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI): a report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group and the American Society of Nuclear Cardiology endorsed by the American Heart Association.

    Science.gov (United States)

    Brindis, Ralph G; Douglas, Pamela S; Hendel, Robert C; Peterson, Eric D; Wolk, Michael J; Allen, Joseph M; Patel, Manesh R; Raskin, Ira E; Hendel, Robert C; Bateman, Timothy M; Cerqueira, Manuel D; Gibbons, Raymond J; Gillam, Linda D; Gillespie, John A; Hendel, Robert C; Iskandrian, Ami E; Jerome, Scott D; Krumholz, Harlan M; Messer, Joseph V; Spertus, John A; Stowers, Stephen A

    2005-10-18

    Under the auspices of the American College of Cardiology Foundation (ACCF) and the American Society of Nuclear Cardiology (ASNC), an appropriateness review was conducted for radionuclide cardiovascular imaging (RNI), specifically gated single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI). The review assessed the risks and benefits of the imaging test for several indications or clinical scenarios and scored them based on a scale of 1 to 9, where the upper range (7 to 9) implies that the test is generally acceptable and is a reasonable approach, and the lower range (1 to 3) implies that the test is generally not acceptable and is not a reasonable approach. The mid range (4 to 6) implies that the test may be generally acceptable and may be a reasonable approach for the indication. The indications for this review were primarily drawn from existing clinical practice guidelines and modified based on discussion by the ACCF Appropriateness Criteria Working Group and the Technical Panel members who rated the indications. The method for this review was based on the RAND/UCLA approach for evaluating appropriateness, which blends scientific evidence and practice experience. A modified Delphi technique was used to obtain first- and second-round ratings of 52 clinical indications. The ratings were done by a Technical Panel with diverse membership, including nuclear cardiologists, referring physicians (including an echocardiographer), health services researchers, and a payer (chief medical officer). These results are expected to have a significant impact on physician decision making and performance, reimbursement policy, and future research directions. Periodic assessment and updating of criteria will be undertaken as needed.

  9. Filters in 2D and 3D Cardiac SPECT Image Processing

    Directory of Open Access Journals (Sweden)

    Maria Lyra

    2014-01-01

    Full Text Available Nuclear cardiac imaging is a noninvasive, sensitive method providing information on cardiac structure and physiology. Single photon emission tomography (SPECT evaluates myocardial perfusion, viability, and function and is widely used in clinical routine. The quality of the tomographic image is a key for accurate diagnosis. Image filtering, a mathematical processing, compensates for loss of detail in an image while reducing image noise, and it can improve the image resolution and limit the degradation of the image. SPECT images are then reconstructed, either by filter back projection (FBP analytical technique or iteratively, by algebraic methods. The aim of this study is to review filters in cardiac 2D, 3D, and 4D SPECT applications and how these affect the image quality mirroring the diagnostic accuracy of SPECT images. Several filters, including the Hanning, Butterworth, and Parzen filters, were evaluated in combination with the two reconstruction methods as well as with a specified MatLab program. Results showed that for both 3D and 4D cardiac SPECT the Butterworth filter, for different critical frequencies and orders, produced the best results. Between the two reconstruction methods, the iterative one might be more appropriate for cardiac SPECT, since it improves lesion detectability due to the significant improvement of image contrast.

  10. Quantification of myocardium at risk in myocardial perfusion SPECT by co-registration and fusion with delayed contrast-enhanced magnetic resonance imaging--an experimental ex vivo study.

    Science.gov (United States)

    Ugander, Martin; Soneson, Helen; Engblom, Henrik; van der Pals, Jesper; Erlinge, David; Heiberg, Einar; Arheden, Håkan

    2012-01-01

    Myocardial perfusion single-photon emission computed tomography (MPS) can be used to assess myocardium at risk in occlusive coronary ischaemia. The aim was to develop a method to quantify myocardium at risk as perfusion defect size on ex vivo MPS using co-registration and fusion with ex vivo magnetic resonance imaging (MRI). Pigs (n = 19) were injected 99mTc-tetrofosmin prior to concluding 40 min of coronary artery occlusion, followed by reperfusion and MRI contrast injection. The excised heart was imaged with T1-weighted MRI and MPS, and images were co-registered using freely available software (Segment v1.8, http://segment.heiberg.se). The left ventricle was semi-automatically delineated in MRI and copied to MPS. The threshold for a MPS perfusion defect was defined as the mean counts in the MPS image at the MRI-determined border between remote myocardium and air. The threshold was measured using count maxima set to the 100th-95th percentile of counts within the myocardium. The count maximum that gave the lowest threshold variability (SD) was considered the most robust. A count maximum using the 100th percentile yielded a threshold of (mean ± SD) 55 ± 6·2%. This method showed the lowest SD compared to 99th-95th percentile count maxima (6·6-7·2%). We describe a method for objective quantification of myocardium at risk as perfusion defect size on MPS using knowledge of the anatomy of the myocardium from co-registered MRI. This enables simultaneous quantification of myocardium at risk by MPS and infarct size by MRI for the evaluation of treatments for myocardial infarction. © 2011 The Authors. Clinical Physiology and Functional Imaging © 2011 Scandinavian Society of Clinical Physiology and Nuclear Medicine.

  11. Investigation of dynamic SPECT measurements of the arterial input function in human subjects using simulation, phantom and human studies.

    Science.gov (United States)

    Winant, Celeste D; Aparici, Carina Mari; Zelnik, Yuval R; Reutter, Bryan W; Sitek, Arkadiusz; Bacharach, Stephen L; Gullberg, Grant T

    2012-01-21

    Computer simulations, a phantom study and a human study were performed to determine whether a slowly rotating single-photon computed emission tomography (SPECT) system could provide accurate arterial input functions for quantification of myocardial perfusion imaging using kinetic models. The errors induced by data inconsistency associated with imaging with slow camera rotation during tracer injection were evaluated with an approach called SPECT/P (dynamic SPECT from positron emission tomography (PET)) and SPECT/D (dynamic SPECT from database of SPECT phantom projections). SPECT/P simulated SPECT-like dynamic projections using reprojections of reconstructed dynamic (94)Tc-methoxyisobutylisonitrile ((94)Tc-MIBI) PET images acquired in three human subjects (1 min infusion). This approach was used to evaluate the accuracy of estimating myocardial wash-in rate parameters K(1) for rotation speeds providing 180° of projection data every 27 or 54 s. Blood input and myocardium tissue time-activity curves (TACs) were estimated using spatiotemporal splines. These were fit to a one-compartment perfusion model to obtain wash-in rate parameters K(1). For the second method (SPECT/D), an anthropomorphic cardiac torso phantom was used to create real SPECT dynamic projection data of a tracer distribution derived from (94)Tc-MIBI PET scans in the blood pool, myocardium, liver and background. This method introduced attenuation, collimation and scatter into the modeling of dynamic SPECT projections. Both approaches were used to evaluate the accuracy of estimating myocardial wash-in parameters for rotation speeds providing 180° of projection data every 27 and 54 s. Dynamic cardiac SPECT was also performed in a human subject at rest using a hybrid SPECT/CT scanner. Dynamic measurements of (99m)Tc-tetrofosmin in the myocardium were obtained using an infusion time of 2 min. Blood input, myocardium tissue and liver TACs were estimated using the same spatiotemporal splines. The

  12. Investigation of dynamic SPECT measurements of the arterial input function in human subjects using simulation, phantom and human studies

    Science.gov (United States)

    Winant, Celeste D.; Aparici, Carina Mari; Zelnik, Yuval R.; Reutter, Bryan W.; Sitek, Arkadiusz; Bacharach, Stephen L.; Gullberg, Grant T.

    2012-01-01

    Computer simulations, a phantom study and a human study were performed to determine whether a slowly rotating single-photon computed emission tomography (SPECT) system could provide accurate arterial input functions for quantification of myocardial perfusion imaging using kinetic models. The errors induced by data inconsistency associated with imaging with slow camera rotation during tracer injection were evaluated with an approach called SPECT/P (dynamic SPECT from positron emission tomography (PET)) and SPECT/D (dynamic SPECT from database of SPECT phantom projections). SPECT/P simulated SPECT-like dynamic projections using reprojections of reconstructed dynamic 94Tc-methoxyisobutylisonitrile (94Tc-MIBI) PET images acquired in three human subjects (1 min infusion). This approach was used to evaluate the accuracy of estimating myocardial wash-in rate parameters K1 for rotation speeds providing 180° of projection data every 27 or 54 s. Blood input and myocardium tissue time-activity curves (TACs) were estimated using spatiotemporal splines. These were fit to a one-compartment perfusion model to obtain wash-in rate parameters K1. For the second method (SPECT/D), an anthropomorphic cardiac torso phantom was used to create real SPECT dynamic projection data of a tracer distribution derived from 94Tc-MIBI PET scans in the blood pool, myocardium, liver and background. This method introduced attenuation, collimation and scatter into the modeling of dynamic SPECT projections. Both approaches were used to evaluate the accuracy of estimating myocardial wash-in parameters for rotation speeds providing 180° of projection data every 27 and 54 s. Dynamic cardiac SPECT was also performed in a human subject at rest using a hybrid SPECT/CT scanner. Dynamic measurements of 99mTc-tetrofosmin in the myocardium were obtained using an infusion time of 2 min. Blood input, myocardium tissue and liver TACs were estimated using the same spatiotemporal splines. The spatiotemporal maximum

  13. Radiopharmaceuticals for SPECT cancer detection

    Science.gov (United States)

    Chernov, V. I.; Medvedeva, A. A.; Zelchan, R. V.; Sinilkin, I. G.; Stasyuk, E. S.; Larionova, L. A.; Slonimskaya, E. M.; Choynzonov, E. L.

    2016-08-01

    The purpose of the study was to assess the efficacy of single photon emission computed tomography (SPECT) with 199Tl and 99mTc-MIBI in the detection of breast, laryngeal and hypopharyngeal cancers. A total of 220 patients were included into the study: 120 patients with breast lesions (100 patients with breast cancer and 20 patients with benign breast tumors) and 100 patients with laryngeal/hypopharyngeal diseases (80 patients with laryngeal/hypopharyngeal cancer and 20 patients with benign laryngeal/hypopharyngeal lesions). No abnormal 199Tl uptake was seen in all patients with benign breast and laryngeal lesions, indicating a 100% specificity of 199Tl SPECT. In the breast cancer patients, the increased 199Tl uptake in the breast was visualized in 94.8% patients, 99mTc-MIBI—in 93.4% patients. The increased 199Tl uptake in axillary lymph nodes was detected in 60% patients, and 99mTc-MIBI—in 93.1% patients. In patients with laryngeal/hypopharyngeal cancer, the sensitivity of SPECT with 199Tl and 99mTc-MIBI was 95%. The 199Tl SPECT sensitivity in identification of regional lymph node metastases in the patients with laryngeal/hypopharyngeal cancer was 75% and the 99mTc-MIBI SPECT sensitivity was 17%. The data obtained showed that SPECT with 199Tl and 99mTc-MIBI can be used as one of the additional imaging methods in detection of tumors.

  14. Comparative study of diverse model building strategies for 3D-ASM segmentation of dynamic gated SPECT data

    Science.gov (United States)

    Tobon-Gomez, C.; Butakoff, C.; Ordas, S.; Aguade, S.; Frangi, A. F.

    2007-03-01

    Over the course of the last two decades, myocardial perfusion with Single Photon Emission Computed Tomography (SPECT) has emerged as an established and well-validated method for assessing myocardial ischemia, viability, and function. Gated-SPECT imaging integrates traditional perfusion information along with global left ventricular function. Despite of these advantages, inherent limitations of SPECT imaging yield a challenging segmentation problem, since an error of only one voxel along the chamber surface may generate a huge difference in volume calculation. In previous works we implemented a 3-D statistical model-based algorithm for Left Ventricle (LV) segmentation of in dynamic perfusion SPECT studies. The present work evaluates the relevance of training a different Active Shape Model (ASM) for each frame of the gated SPECT imaging acquisition in terms of their subsequent segmentation accuracy. Models are subsequently employed to segment the LV cavity of gated SPECT studies of a virtual population. The evaluation is accomplished by comparing point-to-surface (P2S) and volume errors, both against a proper Gold Standard. The dataset comprised 40 voxel phantoms (NCAT, Johns Hopkins, University of of North Carolina). Monte-Carlo simulations were generated with SIMIND (Lund University) and reconstructed to tomographic slices with ASPIRE (University of Michigan).

  15. Myocordial perfusion SPECT with dipyridamole stress test in cardiac syndrome X

    Energy Technology Data Exchange (ETDEWEB)

    Czepczynski, R.; Smolarek, I.; Sowinski, J. [Nuclear Medicine Unit, Dept. of Endocrinology and Metabolism, Poznan Univ. of Medical Sciences, Poznan (Poland); Rogacka, D.; Kazmierczak, M.; Wysocki, H. [Dept. of Intensive Care and Cardiology, Poznan Univ. of Medical Sciences, Poznan (Poland)

    2006-07-01

    Cardiac syndrome X defines patients with typical anginal chest pain, a positive exercise ECG stress test and angiographically normal coronary arteries. Aim of this study was to evaluate the role of myocardial perfusion SPECT with dipyridamole stress in the diagnosis of cardiac syndrome X. Patients, methods: 68 patients with syndrome X aged 32 to 60 years were subjected to myocardial imaging using {sup 99m}Tc-MIBI according to the two-days protocol: at rest and after dipyridamole infusion. Semiquantitative evaluation of the images was based on the assessment of {sup 99m}Tc-MIBI uptake in 17 myocardial segments using a 5-points scale (0 point - normal uptake, 4 points - no uptake). Scores obtained in each segment were summed up, constituting the summed rest score (SRS) and summed stress score (SSS). Results: mean SRS was 7.9 {+-} 4.8 and mean SSS was 7.2 {+-} 4.4 (non-significant difference). Individual comparison of SRS and SSS values revealed three patterns of scintigraphic images: (1) in 25 patients (36.8%), a paradoxical improvement of perfusion at stress images was found, (2) in 23 patients (33.8%), the myocardial perfusion deteriorated after dipyridamole, (3) in 20 patients (29.4%), no significant change of the myocordial perfusion between rest and stress images occurred. Conclusions: in cardiac syndrome X, myocardial SPECT with dipyridamole stress shows different patterns of myocardial perfusion that reflects heterogeneity of this pathology. (orig.)

  16. SPECT in Focal Epilepsies

    Directory of Open Access Journals (Sweden)

    Roderick Duncan

    2000-01-01

    Full Text Available Brain perfusion changes during seizures were first observed in the 1930s. Single Photon Emission Computed Tomography (SPECT was developed in the 1970s, and tracers suitable for the imaging of regional cerebral perfusion (rCP became available in the 1980s. The method was first used to study rCP in the interictal phase, and this showed areas of low perfusion in a proportion of cases, mainly in patients with temporal lobe epilepsies. However, the trapping paradigm of tracers such as hexamethyl propyleneamine oxime (HMPAO provided a practicable method of studying changes in rCP during seizures, and a literature was established in the late 1980s and early 1990s showing a typical sequence of changes during and after seizures of mesial temporal lobe origin; the ictal phase was associated with large increases in perfusion throughout the temporal lobe, with first the lateral, then the mesial temporal lobe becoming hypoperfused in the postictal phase. Activation and inhibition of other structures, such as the basal ganglia and frontal cortex, were also seen. Studies of seizures originating elsewhere in the brain have shown a variety of patterns of change, according to the structures involved. These changes have been used practically to aid the process of localisation of the epileptogenic zone so that epilepsy surgery can be planned.

  17. Organ volume estimation using SPECT

    CERN Document Server

    Zaidi, H

    1996-01-01

    Knowledge of in vivo thyroid volume has both diagnostic and therapeutic importance and could lead to a more precise quantification of absolute activity contained in the thyroid gland. In order to improve single-photon emission computed tomography (SPECT) quantitation, attenuation correction was performed according to Chang's algorithm. The dual-window method was used for scatter subtraction. We used a Monte Carlo simulation of the SPECT system to accurately determine the scatter multiplier factor k. Volume estimation using SPECT was performed by summing up the volume elements (voxels) lying within the contour of the object, determined by a fixed threshold and the gray level histogram (GLH) method. Thyroid phantom and patient studies were performed and the influence of 1) fixed thresholding, 2) automatic thresholding, 3) attenuation, 4) scatter, and 5) reconstruction filter were investigated. This study shows that accurate volume estimation of the thyroid gland is feasible when accurate corrections are perform...

  18. PET and SPECT in neurology

    Energy Technology Data Exchange (ETDEWEB)

    Dierckx, Rudi A.J.O. [Groningen University Medical Center (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging; Ghent Univ. (Belgium). Dept. of Radiology and Nuclear Medicine; Vries, Erik F.J. de; Waarde, Aren van [Groningen University Medical Center (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging; Otte, Andreas (ed.) [Univ. of Applied Sciences Offenburg (Germany). Faculty of Electrical Engineering and Information Technology

    2014-07-01

    PET and SPECT in Neurology highlights the combined expertise of renowned authors whose dedication to the investigation of neurological disorders through nuclear medicine technology has achieved international recognition. Classical neurodegenerative disorders are discussed as well as cerebrovascular disorders, brain tumors, epilepsy, head trauma, coma, sleeping disorders, and inflammatory and infectious diseases of the CNS. The latest results in nuclear brain imaging are detailed. Most chapters are written jointly by a clinical neurologist and a nuclear medicine specialist to ensure a multidisciplinary approach. This state-of-the-art compendium will be valuable to anybody in the field of neuroscience, from the neurologist and the radiologist/nuclear medicine specialist to the interested general practitioner and geriatrician. It is the second volume of a trilogy on PET and SPECT imaging in the neurosciences, the other volumes covering PET and SPECT in psychiatry and in neurobiological systems.

  19. Impact of image processing in the detection of ischaemia using CZT-SPECT/CT.

    Science.gov (United States)

    Koopman, Daniëlle; van Dalen, Jorn A; Slump, Cornelis H; Lots, Dimitri; Timmer, Jorik R; Jager, Pieter L

    2015-01-01

    The new multipinhole cardiac single photon emission computed tomography/computed tomography (SPECT/CT) cameras with cadmium-zinc-telluride (CZT) detectors are highly sensitive and produce images of high quality but rely on complex dedicated reconstruction algorithms. The aim of this study was to determine the impact of various processing steps on image formation and in the detection of ischaemia in CZT-SPECT/CT both with and without attenuation correction (AC). Data on 20 consecutive patients who underwent a 1-day protocol stress-rest SPECT/CT using 99mTc-tetrofosmin were processed twice by three experienced operators, yielding 120 AC and 120 noncorrected (NC) data sets. Processing steps included selection and determination of myocardial axes, manual SPECT/CT coregistration for AC and myocardial masking. Using the 17-segment cardiac model, differences between stress and rest segmental uptake (%) were calculated for NC and AC image sets. Both interoperator and intraoperator variations were considered significant for the diagnosis of ischaemia when greater than 5%. The mean interoperator variations were 2.4±1.4% (NC) and 3.8±1.9% (AC) (Pprocessed cases, operator variation was larger than 5% and therefore potentially clinically interfering with the diagnosis of ischaemia. Differences between interoperator and intraoperator variations were nonsignificant. Operator variations in the processing of myocardial perfusion image data using CZT-SPECT/CT are significant and may influence the diagnosis of ischaemia, especially when AC is applied. Clearer guidelines for image processing are necessary to improve the reproducibility of the studies and to obtain a more reliable diagnosis of ischaemia.

  20. Adenosine myocardial perfusion single-photon emission computed tomography in women compared with men. Impact of diabetes mellitus on incremental prognostic value and effect on patient management.

    Science.gov (United States)

    Berman, Daniel S; Kang, Xingping; Hayes, Sean W; Friedman, John D; Cohen, Ishac; Abidov, Aiden; Shaw, Leslee J; Amanullah, Aman M; Germano, Guido; Hachamovitch, Rory

    2003-04-02

    This study was designed to assess the incremental prognostic value of adenosine stress myocardial perfusion single-photon emission computed tomography (MPS) in women versus men, and to explore the prognostic impact of diabetes mellitus. Limited data are available regarding the incremental value of adenosine stress MPS for the prediction of cardiac death in women versus men and the impact of diabetes mellitus on post-adenosine MPS outcomes. Of 6,173 consecutive patients who underwent rest thallium-201/adenosine technetium-99m sestamibi MPS, 254 (4.1%) were lost to follow-up, and 586 with early revascularization women and 2,677 men. Women had significantly smaller adenosine stress, rest, and reversible defects than men. During 27.0 +/- 8.8 month follow-up, cardiac death rates were lower in women than men (2.0%/year vs. 2.7%/year, respectively, p men and women as a function of MPS results. Multivariable models revealed that MPS results provided incremental prognostic value over pre-scan data for the prediction of cardiac death in both genders. Also, while comparative unadjusted rates of early (women (p men and women. Importantly, diabetic women had a significantly greater risk of cardiac death compared with other patients. Also, after risk adjustment, patients with insulin-dependent diabetes mellitus (IDDM) had higher risk of cardiac death for any MPS result than patients with non-insulin-dependent diabetes mellitus. The findings suggest that adenosine MPS has comparable incremental value for prediction of cardiac death in women and men and that MPS is appropriately influencing subsequent invasive management decisions in both genders. Diabetic women and patients with IDDM appear to have greater risk of cardiac death than other patients for any MPS result.

  1. Radiopharmaceuticals for SPECT cancer detection

    Energy Technology Data Exchange (ETDEWEB)

    Chernov, V. I., E-mail: chernov@oncology.tomsk.ru; Medvedeva, A. A., E-mail: tickayaAA@oncology.tomsk.ru; Zelchan, R. V., E-mail: r.zelchan@yandex.ru; Sinilkin, I. G., E-mail: sinilkinig@oncology.tomsk.ru [Tomsk Cancer Research Institute, Kooperativny Street 5, Tomsk, 634050 (Russian Federation); Tomsk Polytechnic University, Lenin Avenue 30, Tomsk, 634050 (Russian Federation); Stasyuk, E. S.; Larionova, L. A. [Tomsk Polytechnic University, Lenin Avenue 30, Tomsk, 634050 (Russian Federation); Slonimskaya, E. M.; Choynzonov, E. L. [Tomsk Cancer Research Institute, Kooperativny Street 5, Tomsk, 634050 (Russian Federation)

    2016-08-02

    The purpose of the study was to assess the efficacy of single photon emission computed tomography (SPECT) with {sup 199}Tl and {sup 99}mTc-MIBI in the detection of breast, laryngeal and hypopharyngeal cancers. A total of 220 patients were included into the study: 120 patients with breast lesions (100 patients with breast cancer and 20 patients with benign breast tumors) and 100 patients with laryngeal/hypopharyngeal diseases (80 patients with laryngeal/hypopharyngeal cancer and 20 patients with benign laryngeal/hypopharyngeal lesions). No abnormal {sup 199}Tl uptake was seen in all patients with benign breast and laryngeal lesions, indicating a 100% specificity of {sup 199}Tl SPECT. In the breast cancer patients, the increased {sup 199}Tl uptake in the breast was visualized in 94.8% patients, {sup 99m}Tc-MIBI—in 93.4% patients. The increased {sup 199}Tl uptake in axillary lymph nodes was detected in 60% patients, and {sup 99m}Tc-MIBI—in 93.1% patients. In patients with laryngeal/hypopharyngeal cancer, the sensitivity of SPECT with {sup 199}Tl and {sup 99m}Tc-MIBI was 95%. The {sup 199}Tl SPECT sensitivity in identification of regional lymph node metastases in the patients with laryngeal/hypopharyngeal cancer was 75% and the {sup 99m}Tc-MIBI SPECT sensitivity was 17%. The data obtained showed that SPECT with {sup 199}Tl and {sup 99m}Tc-MIBI can be used as one of the additional imaging methods in detection of tumors.

  2. Prediction of infarct volume in patients undergoing reperfusion therapy by Tc-99m antimyosin SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Yasuda, T.; Leinbach, R.C.; Khaw, B.A.; Gold, H.K.; Strauss, H.W.

    1984-01-01

    The predictability of infarct volume by Tc-99m antimyosin SPECT was evaluated within 24 hours of chest pain and this was compared to the length of akinesis (AK) from the pre-discharge left ventriculogram (LVgram). Ten patients (pts) with acute myocardial infarction who underwent streptokinase thrombolytic therapy (success 8, failure 2) were subjects of this investigation. None had previous infarction. Average reperfusion time was within 4.5 hours and 20mCi of Tc-99m antimyosin was given intravenously within 8 hours after chest pain; SPECT imaging was performed within 18 hours after injection. Infarct volume was calculated from SPECT and expressed as grams of myocardial infarction (GMI). Ten days later, a 30/sup 0/RAO contrast LVgram was recorded and the length of AK (corrected for magnification) was measured along the LV border at the end-diastolic phase and expressed as cm of AK. GMI and AK were measured independently without knowledge of each other. Results are given. The data demonstrate a good correlation of GMI and AK. Infarct volume can be measured by antimyosin SPECT within 24 hours of chest pain and predict residual LV dysfunction in pts undergoing reperfusion therapy.

  3. A randomized, multicenter, multivendor study of myocardial perfusion imaging with regadenoson CT perfusion vs single photon emission CT.

    Science.gov (United States)

    Cury, Ricardo C; Kitt, Therese M; Feaheny, Kathleen; Blankstein, Ron; Ghoshhajra, Brian B; Budoff, Matthew J; Leipsic, Jonathon; Min, James K; Akin, Jamie; George, Richard T

    2015-01-01

    Myocardial CT perfusion (CTP) is a promising tool for the detection of myocardial ischemia. We hypothesize that regadenoson CTP is noninferior to regadenoson single photon emission CT (SPECT) for detecting or excluding myocardial ischemia. Patients (men ≥ 45 years; women ≥ 50 years) with known or suspected coronary artery disease (n = 124) were randomized to 1 of 2 diagnostic sequences: rest and regadenoson SPECT on day 1, then regadenoson CTP and rest CTP (and coronary CT angiography [CTA]) (CTA; same acquisition) on day 2 or regadenoson CTP and rest CTP (and CTA) on Day 1, then rest and regadenoson SPECT on day 2. Scanning platforms included 64-, 128-, 256-, and 320-slice systems. The primary analysis examined the agreement rate between CTP and SPECT for detecting or excluding reversible ischemia in ≥ 2 myocardial segments as assessed by independent, blinded readers. Complete and interpretable CTP and SPECT scans were obtained for 110 patients. Regadenoson CTP was noninferior to SPECT for detecting or excluding reversible ischemia with an agreement rate of 0.87 (95% confidence interval [CI], 0.77-0.97) and sensitivity and specificity of 0.90 (95% CI, 0.71-1.00) and 0.84 (95% CI, 0.77-0.91), respectively. The agreement rate for detecting or excluding ≥ 1 fixed defects by regadenoson CTP and SPECT was 0.86 (95% CI, 0.74-0.98). With SPECT as the reference standard, the diagnostic accuracies for detecting or excluding ischemia by regadenoson CTP and CTA alone were 0.85 (95% CI, 0.78-0.91) and 0.69 (95% CI, 0.60-0.77), respectively. This study establishes the noninferiority of regadenoson CTP to SPECT for detecting or excluding myocardial ischemia. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  4. PET and SPECT in psychiatry

    Energy Technology Data Exchange (ETDEWEB)

    Dierckx, Rudi A.J.O. [University Medical Center Groningen (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging; Ghent Univ. (Belgium); Otte, Andreas [Univ. of Applied Sciences Offenburg (Germany). Faculty of Electrical Engineering and Information Technology; Vries, Erik F.J. de; Waarde, Aren van (eds.) [University Medical Center Groningen (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging

    2014-09-01

    Covers classical psychiatric disorders as well as other subjects such as suicide, sleep, eating disorders, and autism. Emphasis on a multidisciplinary approach. Written by internationally acclaimed experts. PET and SPECT in Psychiatry showcases the combined expertise of renowned authors whose dedication to the investigation of psychiatric disease through nuclear medicine technology has achieved international recognition. The classical psychiatric disorders as well as other subjects - such as suicide, sleep, eating disorders, and autism - are discussed and the latest results in functional neuroimaging are detailed. Most chapters are written jointly by a clinical psychiatrist and a nuclear medicine expert to ensure a multidisciplinary approach. This state of the art compendium will be valuable to all who have an interest in the field of neuroscience, from the psychiatrist and the radiologist/nuclear medicine specialist to the interested general practitioner and cognitive psychologist. It is the first volume of a trilogy on PET and SPECT imaging in the neurosciences; other volumes will focus on PET and SPECT in neurology and PET and SPECT of neurobiological systems.

  5. SPECT og PET i neurobiologien

    DEFF Research Database (Denmark)

    Paulson, O B; Lassen, N A

    1997-01-01

    PET (positron emission tomography) and SPECT (single photon emission computed tomography) are isotopic methods in which the distribution is registered of radiolabelled tracers given in such small amounts that they are without effect on the organism or the organism's disposal of them. Thus, a series...

  6. Role of myocardial perfusion single photon emission computed tomography in pediatric cardiology practice

    Directory of Open Access Journals (Sweden)

    Sundaram P

    2009-01-01

    Full Text Available Diagnostic and prognostic power of myocardial perfusion imaging in patients with coronary artery disease has been demonstrated with planar imaging which was further improvised with addition of gated SPECT and newer Technetium labeled myocardial perfusion tracers like SestaMIBI, Tetrofosmin. Myocardial perfusion abnormalities at rest and after stress are considered to be the best predictors of cardiac event-free survival in adults with ischemic heart disease. This article highlights various myocardial perfusion imaging (MPIradiopharmaceuticals, exercise procedures, pharmacological stress protocols, indications for MPI and myocardial perfusion patterns in children with some of the common congenital and acquired heart diseases.

  7. Myocardial Ischemia

    Science.gov (United States)

    ... pectoris: Chest pain caused by myocardial ischemia. www.uptodate.com/home. Accessed June 1, 2015. Deedwania PC. Silent myocardial ischemia: Epidemiology and pathogenesis. www.uptodate.com/home. Accessed June 1, 2015. Mann DL, ...

  8. Coronary blood flow and thallium 201 uptake in rejecting rat heart transplantations

    Energy Technology Data Exchange (ETDEWEB)

    Bergsland, J.; Hwang, K.; Driscoll, R.; Carr, E.A.; Wright, J.R.; Curran-Everett, D.C.; Carroll, M.; Krasney, E.; Krasney, J.A. (Veterans Administration Medical Center, Buffalo, NY (USA))

    1989-03-01

    The effects of rejection on coronary flow (CAF) in heart allografts are unclear, although previous evidence with cardiac imaging agents indicates impaired flow during advanced rejection. The purpose of this study was to measure CAF in heterotopically placed heart grafts. Lewis rats (LEW) received grafts from either syngeneic Lewis rats (LEW/LEW group) or allogeneic ACI rats (ACI/LEW group). CAF was measured in both the transplanted and native hearts with radiolabeled microspheres. Rejection was measured histologically (grades 0 (absent) to 4+ (severe)). In addition systemic blood pressure and cardiac outputs of the native hearts were determined with microspheres. Different animals were studied during relatively early (4 days) and late (6 days) rejection. Among the 4-day animals a cyclosporine-treated group was included (ACI/LEW CyA). In 6-day rats CAF in allografts was lower (0.56 +/- .06 ml/gm/min) compared with syngeneic grafts (1.72 +/- 0.4 ml/gm/min) (p less than 0.05). The CAF in the native hearts did not differ significantly but was higher than in the grafts in both groups. Heart rates were reduced in allografts (p less than 0.05). It is interesting that arterial pressure and cardiac output were significantly lower in animals bearing allogeneic than syngeneic grafts. In rats studied at 4 days graft CAF was lower than in the native heart in both the LEW/LEW and ACI/LEW groups, but there was no significant difference in behavior between groups. The same was true for a cyclosporine-treated group. Graft heart rates were similar in all 4-day rats.

  9. Evaluation of thallium-201 scanning for detection of latent coronary artery disease

    Science.gov (United States)

    Johnson, P. C.; Leblanc, A.; Deboer, L.; Jhingran, S.

    1978-01-01

    The use of thallium imaging as a noninvasive method to accurately screen shuttle passengers for latent coronary artery disease was investigated. All radionuclide procedures were performed using an Anger type camera with a high resolution collimator. A minimum of 200,000 counts were collected for each image using a 20% window centered on the 69-83 keV X-rays. For the images obtained following injection with the patient at rest, the testing was begun 10 minutes after injection. Injections of TT during exercise were made at a point near the termination of the treadmill procedure as determined by either the appearance of ST segment changes on the electrocardiogram consistant with subendocardial ischemia, the appearance of angina-like chest pain in the patient or fatigue in the patient which required cessation of the test. The severity of heart disease was based on the medical history, physical exam, exercise electrocardiograms, chest X-rays and the coronary arteriogram.

  10. Effect of procainamide, lidocaine and diphenylhydantoin on thallium-201 chloride uptake

    Energy Technology Data Exchange (ETDEWEB)

    Schachner, E.R.; Oster, Z.H.; Sacker, D.F.; Som, P.; Atkins, H.L.

    1987-01-01

    The effect of procainamide, lidocaine and diphenylhydantoin on the organ distribution (particularly the heart) of /sup 201/Tl chloride in rats was studied. The results show that diphenylhydantoin significantly decreases the uptake of /sup 201/Tl chloride in several organs of rats previously treated with this drug. No statistically significant effects were noted with procainamide and lidocaine.

  11. Thallium-201: Autoradiography in pigmented mice and melanin-binding in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Tjaelve, H.; Nilsson, M.; Larsson, B. (Uppsala Univ. (Sweden))

    1982-01-01

    Autoradiography with /sup 201/Tl/sup +/ in C57Bl mice showed a strong labelling of the eye melanin and of pigmented hair follicles. An analysis of the affinity of thallium for pigment from cow eyes indicated a binding to three groups of sites and showed a marked sensitivity to the addition of H/sup +/-ions. The results are consistent with the conception that a binding of thallium occurs to the free carboxyl groups of the melanin and that the structure of the polymer has a marked influence on the affinity. Similar results have previously been obtained with other cations. There was no indication that the strong in vivo affinity of thallium to melanin is due to a more firm binding than for other cations which do not localize on melanin in vivo. Instead, the ability of cations to pass the melanocyte membranes and reach the melanin granules is probably decisive for whether a melanin-binding will take place in vivo. Toxic effects on the eye and epilation are symptoms of thallium intoxication which may be related to its melanin-binding. The fate of /sup 201/Tl/sup +/ in some other tissues is also described and discussed.

  12. Adenosine-stress dynamic real-time myocardial perfusion CT and adenosine-stress first-pass dual-energy myocardial perfusion CT for the assessment of acute chest pain: Initial results

    Energy Technology Data Exchange (ETDEWEB)

    Weininger, Markus [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Department of Medicine, Division of Cardiology, Medical University of South Carolina, Charleston, SC (United States); Ramachandra, Ashok [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Fink, Christian [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University (Germany); Rowe, Garrett W.; Costello, Philip [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Henzler, Thomas [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University (Germany)

    2012-12-15

    Purpose: Recent innovations in CT enable the evolution from mere morphologic imaging to dynamic and functional testing. We describe our initial experience performing myocardial stress perfusion CT in a clinical population with acute chest pain. Methods and materials: Myocardial stress perfusion CT was performed on twenty consecutive patients (15 men, 5 women; mean age 65 ± 8 years) who presented with acute chest pain and were clinically referred for stress/rest SPECT and cardiac MRI. Prior to CT each patient was randomly assigned either to Group A or to Group B in a consecutive order (10 patients per group). Group A underwent adenosine-stress dynamic real-time myocardial perfusion CT using a novel “shuttle” mode on a 2nd generation dual-source CT. Group B underwent adenosine-stress first-pass dual-energy myocardial perfusion CT using the same CT scanner in dual-energy mode. Two experienced observers visually analyzed all CT perfusion studies. CT findings were compared with MRI and SPECT. Results: In Group A 149/170 myocardial segments (88%) could be evaluated. Real-time perfusion CT (versus SPECT) had 86% (84%) sensitivity, 98% (92%) specificity, 94% (88%) positive predictive value, and 96% (92%) negative predictive value in comparison with perfusion MRI for the detection of myocardial perfusion defects. In Group B all myocardial segments were available for analysis. Compared with MRI, dual-energy myocardial perfusion CT (versus SPECT) had 93% (94%) sensitivity, 99% (98%) specificity, 92% (88%) positive predictive value, and 96% (94%) negative predictive value for detecting hypoperfused myocardial segments. Conclusion: Our results suggest the clinical feasibility of myocardial perfusion CT imaging in patients with acute chest pain. Compared to MRI and SPECT both, dynamic real-time perfusion CT and first-pass dual-energy perfusion CT showed good agreement for the detection of myocardial perfusion defects.

  13. Comparison of dual-source 64-slice adenosine stress CT perfusion with stress-gated SPECT-MPI for evaluation of left ventricular function and volumes.

    Science.gov (United States)

    Uthamalingam, Shanmugam; Gurm, Gagandeep S; Sidhu, Manavjot S; Verdini, Daniel J; Vorasettakarnkij, Yongkasem; Engel, Leif-Christopher; Blankstein, Ron; Mamuya, Wilfred S; Hoffman, Udo; Brady, Thomas J; Cury, Ricardo C; Ghoshhajra, Brian B

    2012-01-01

    Evaluation of left ventricular (LV) volumes and ejection fraction (LVEF) represent important components of pharmacologic stress imaging with either myocardial CT perfusion (CTP) or gated single-photon emission CT (SPECT) myocardial perfusion imaging (SPECT-MPI). We compared measurements of left ventricular function and volumes obtained with CTP and SPECT-MPI. Forty-seven patients (mean age, 62 ± 11 years; male, n = 39) underwent stress CTP and SPECT-MPI. LVEF (in %), end-systolic volume (ESV; in mL), and end-diastolic volume (EDV; in mL) derived from stress CTP images were compared with SPECT-MPI. Stress CTP was in good agreement with SPECT-MPI for quantification of LVEF (r = 0.91), EDV (r = 0.75), and ESV (r = 0.83; all P stress CTP (66% ± 17%) was similar to SPECT-MPI (64% ± 15%). Similar values were also derived for mean EDV (123 ± 30 mL vs 120 ± 34 mL) and ESV (44 ± 28 mL vs 51 ± 34 mL) for CTP and SPECT-MPI, respectively. Good agreement was also shown between both techniques for the assessment of regional wall motion with identical wall motion scores in 95.3% of the segments (κ = 0.79). LVEF and LV volume parameters as determined by dual-source 64-slice adenosine stress CTP show a high correlation with values obtained with stress-gated SPECT-MPI. Copyright © 2012 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  14. The Effect of Milk, Water and Lemon Juice on Various Subdiaphragmatic Activity-Related Artifacts in Myocardial Perfusion Imaging

    OpenAIRE

    Malek; Hedayati; Yaghoobi; Bitarafan-Rajabi; Firoozabadi; Rastgou

    2015-01-01

    Background Subdiaphragmatic activity can produce subdiaphragmatic-related artifacts, which can degrade the quality of myocardial perfusion imaging (MPI). Objectives We examined the impact of drinking milk, water, and lemon juice on different subdiaphragmatic-related artifacts by using 99mTc-sestamibi myocardial single-photon emission computed tomography (SPECT) in order to determine a feasible method for improving the image qualit...

  15. Small-animal SPECT and SPECT/CT : Application in cardiovascular research

    NARCIS (Netherlands)

    Golestani, R.; Wu, C.; Tio, R.A.; Zeebregts, C.J.; Petrov, A.D.; Beekman, F.J.; Dierckx, R.A.J.O.; Boersma, H.H.; Slart, R.H.J.A.

    2010-01-01

    Preclinical cardiovascular research using noninvasive radionuclide and hybrid imaging systems has been extensively developed in recent years. Single photon emission computed tomography (SPECT) is based on the molecular tracer principle and is an established tool in noninvasive imaging. SPECT uses

  16. Nuclear cardiac imaging for the assessment of myocardial viability.

    Science.gov (United States)

    Slart, R H J A; Bax, J J; van der Wall, E E; van Veldhuisen, D J; Jager, P L; Dierckx, R A

    2005-11-01

    An important aspect of the diagnostic and prognostic work-up of patients with ischaemic cardiomyopathy is the assessment of myocardial viability. Patients with left ventricular dysfunction who have viable myocardium are the patients at highest risk because of the potential for ischaemia but at the same time benefit most from revascularisation. It is important to identify viable myocardium in these patients, and radionuclide myocardial scintigraphy is an excellent tool for this. Single-photon emission computed tomography perfusion scintigraphy (SPECT), whether using 201thallium, 99mTc-sestamibi, or 99mTc- tetrofosmin, in stress and/or rest protocols, has consistently been shown to be an effective modality for identifying myocardial viability and guiding appropriate management. Metabolic and perfusion imaging with positron emission tomography radiotracers frequently adds additional information and is a powerful tool for predicting which patients will have an improved outcome from revascularisation. New techniques in the nuclear cardiology field, such as attenuation corrected SPECT, dual isotope simultaneous acquisition (DISA) SPECT and gated FDG PET are promising and will further improve the detection of myocardial viability. Also the combination of multislice computed tomography scanners with PET opens possibilities of adding coronary calcium scoring and noninvasive coronary angiography to myocardial perfusion imaging and quantification.

  17. [Brain SPECT in Lewy body dementia].

    Science.gov (United States)

    Farid, Karim; Volpe-Gillot, Lisette; Caillat-Vigneron, Nadine

    2011-06-01

    Dementia of Lewy bodies (DLB) is the second cause of degenerative dementia. There is many clinical presentation of the disease. Brain single photon computed tomography (SPECT) is a simple way to investigate routinely the cerebral blood flow. On cerebral perfusion SPECT, DLB is accompanied by diffuse cortical hypoperfusion predominantly at the posterior cortex and may affect the associative and primary visual areas in relation to neuronal loss or dysfunction. DLB patients have striatal hypofixation on cerebral neurotranmission SPECT-DaTSCAN(®), related with dopaminergic loss. Brain SPECT is useful in the differential diagnosis between DLB and other dementia. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  18. SPECT of aged backache patients

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Shigehiko; Nishikimi, Junzo; Mizuno, Naokado; Watanabe, Kentaro; Kondo, Masaki; Ozaki, Satoshi; Urasaki, Tetsuya; Muro, Toshiyuki [Prefectural Tajimi Hospital, Gifu (Japan)

    1995-12-01

    Single photon emission computed tomography (SPECT) using {sup 99m}Tc-HMDP was performed on 53 middle-aged or elderly patients (male 20, female, 33; age range, 40-80 years old) with lumbago, i.e., 25 patients with lumbar spondylosis, 15 with lumbar degenerative spondylolisthesis, 4 with spondylolytic spondylolisthesis, 3 with compression fracture, 3 with pulurent spondylitis, 2 with spondylous osteoporosis, and 1 with spinal osteodesmosis. {sup 99m}Tc-HMDP (740 MBq) was intravenously injected and regular SPECT was performed at 3 hours. Gamma camera was performed for about 10 seconds with 5deg intervals, and 36 steps (180deg) of collection was completed after about 6 minutes. The radioisotope accumulation, the presence or absence of sthenia, and its site were evaluated. Forty-seven (88.7%) patients showed excessive accumulation, i.e., 40 (75.5%) in peripheral vertebral osteophyte, 31 (58.5%) in vertebral articulations, and 10 (18.9%) in whole vertebral body. Significantly increased bilateral excessive accumulation was admitted in the vertebral articulations of sliding disc in degenerative spondylolisthesis. SPECT is considered useful in understanding the pathophysiology of degenerative lumber diseases. (S.Y.).

  19. Use of a compact pixellated gamma camera for small animal pinhole SPECT imaging.

    Science.gov (United States)

    Zeniya, Tsutomu; Watabe, Hiroshi; Aoi, Toshiyuki; Kim, Kyeong Min; Teramoto, Noboru; Takeno, Takeshi; Ohta, Yoichiro; Hayashi, Takuya; Mashino, Hiroyuki; Ota, Toshihiro; Yamamoto, Seiichi; Iida, Hidehiro

    2006-07-01

    Pinhole SPECT which permits in vivo high resolution 3D imaging of physiological functions in small animals facilitates objective assessment of pharmaceutical development and regenerative therapy in pre-clinical trials. For handiness and mobility, the miniature size of the SPECT system is useful. We developed a small animal SPECT system based on a compact high-resolution gamma camera fitted to a pinhole collimator and an object-rotating unit. This study was aimed at evaluating the basic performance of the detection system and the feasibility of small animal SPECT imaging. The gamma camera consists of a 22 x 22 pixellated scintillator array of 1.8 mm x 1.8 mm x 5 mm NaI(Tl crystals with 0.2-mm gap between the crystals coupled to a 2" flat panel position-sensitive photomultiplier tube (Hamamatsu H8500) with 64 channels. The active imaging region of the camera was 43.8 mm x 43.8 mm. Data acquisition is controlled by a personal computer (Microsoft Windows) through the camera controller. Projection data over 360 degrees for SPECT images are obtained by synchronizing with the rotating unit. The knife-edge pinhole collimators made of tungsten are attached on the camera and have 0.5-mm and 1.0-mm apertures. The basic performance of the detection system was evaluated with 99mTc and 201Tl solutions. Energy resolution, system spatial resolution and linearity of count rate were measured. Rat myocardial perfusion SPECT scans were sequentially performed following intravenous injection of 201TlCl. Projection data were reconstructed using a previously validated pinhole 3D-OSEM method. The energy resolution at 140 keV was 14.8% using a point source. The system spatial resolutions were 2.8-mm FWHM and 2.5-mm FWHM for 99mTc and 201Tl line sources, respectively, at 30-mm source distance (magnification factor of 1.3) using a 1.0-mm pinhole. The linearity between the activity and count rate was good up to 10 kcps. In a rat study, the left ventricular walls were clearly visible in all

  20. Myocardial Bridging

    Directory of Open Access Journals (Sweden)

    Shi-Min Yuan

    2016-02-01

    Full Text Available Abstract Myocardial bridging is rare. Myocardial bridges are most commonly localized in the middle segment of the left anterior descending coronary artery. The anatomic features of the bridges vary significantly. Alterations of the endothelial morphology and the vasoactive agents impact on the progression of atherosclerosis of myocardial bridging. Patients may present with chest pain, myocardial infarction, arrhythmia and even sudden death. Patients who respond poorly to the medical treatment with β-blockers warrant a surgical intervention. Myotomy is a preferred surgical procedure for the symptomatic patients. Coronary stent deployment has been in limited use due to the unsatisfactory long-term results.

  1. Comparison of Tc-99m-sestamibi/(18)FDG DISA SPECT with PET for the detection of viability in patients with coronary artery disease and left ventricular dysfunction

    NARCIS (Netherlands)

    Slart, RHJA; Bax, JJ; de Boer, J; Willemsen, ATM; Mook, Pieter; Oudkerk, M; van der Wall, EE; van Veldhuisen, DJ; Jager, PL

    Purpose: Dual-isotope simultaneous acquisition (DISA) single-photon emission computed tomography ( SPECT) is an attractive technique as it permits assessment of both myocardial glucose metabolism and perfusion within a single session, but few data on its accuracy for the assessment of viability are

  2. Clinical applications of SPECT-CT

    Energy Technology Data Exchange (ETDEWEB)

    Ahmadzadehfar, Hojjat; Biersack, Hans-Juergen (eds.) [University Hospital Bonn (Germany). Dept. of Nuclear Medicine

    2014-06-01

    Covers the full spectrum of clinical applications of SPECT/CT in diagnosis of benign and malignant diseases. Includes chapters on the use of SPECT/CT for dosimetry and for therapy planning. Completely up to date. Many helpful illustrations. SPECT/CT cameras have considerably improved diagnostic accuracy in recent years. Such cameras allow direct correlation of anatomic and functional information, resulting in better localization and definition of scintigraphic findings. In addition to this anatomic referencing, CT coregistration provides superior quantification of radiotracer uptake based on the attenuation correction capabilities of CT. Useful applications of SPECT/CT have been identified not only in oncology but also in other specialties such as orthopedics and cardiology. This book covers the full spectrum of clinical applications of SPECT/CT in diagnosis and therapy planning of benign and malignant diseases. Opening chapters discuss the technology and physics of SPECT/CT and its use for dosimetry. The role of SPECT/CT in the imaging of a range of pathologic conditions is then addressed in detail. Applications covered include, among others, imaging of the thyroid, bone, and lungs, imaging of neuroendocrine tumors, cardiac scintigraphy, and sentinel node scintigraphy. Individual chapters are also devoted to therapy planning in selective internal radiation therapy of liver tumors and bremsstrahlung SPECT/CT. Readers will find this book to be an essential and up-to-date source of information on this invaluable hybrid imaging technique.

  3. SPECT/CT and pulmonary embolism

    Energy Technology Data Exchange (ETDEWEB)

    Mortensen, Jann [Copenhagen University Hospital, Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark); The Faroese National Hospital, Department of Medicine, Torshavn (Faroe Islands); Gutte, Henrik [Copenhagen University Hospital, Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark); Herlev Hospital, Copenhagen University Hospital, Department of Radiology, Copenhagen (Denmark); University of Copenhagen, Cluster for Molecular Imaging, Faculty of Health Sciences, Copenhagen (Denmark)

    2014-05-15

    Acute pulmonary embolism (PE) is diagnosed either by ventilation/perfusion (V/P) scintigraphy or pulmonary CT angiography (CTPA). In recent years both techniques have improved. Many nuclear medicine centres have adopted the single photon emission CT (SPECT) technique as opposed to the planar technique for diagnosing PE. SPECT has been shown to have fewer indeterminate results and a higher diagnostic value. The latest improvement is the combination of a low-dose CT scan with a V/P SPECT scan in a hybrid tomograph. In a study comparing CTPA, planar scintigraphy and SPECT alone, SPECT/CT had the best diagnostic accuracy for PE. In addition, recent developments in the CTPA technique have made it possible to image the pulmonary arteries of the lungs in one breath-hold. This development is based on the change from a single-detector to multidetector CT technology with an increase in volume coverage per rotation and faster rotation. Furthermore, the dual energy CT technique is a promising modality that can provide functional imaging in combination with anatomical information. Newer high-end CT scanners and SPECT systems are able to visualize smaller subsegmental emboli. However, consensus is lacking regarding the clinical impact and treatment. In the present review, SPECT and SPECT in combination with low-dose CT, CTPA and dual energy CT are discussed in the context of diagnosing PE. (orig.)

  4. Myocardial ischaemia in systemic lupus erythematosus: detection and clinical relevance.

    Science.gov (United States)

    Płazak, Wojciech; Gryga, Krzysztof; Sznajd, Jan; Pasowicz, Mieczysław; Musiał, Jacek; Podolec, Piotr

    2011-01-01

    Severe cardiovascular complications are among the most important causes of mortality in systemic lupus erythematosus (SLE) patients. To assess the usefulness of echocardiography, ECG, and coronary artery calcium scoring (CACS) in the detection of myocardial ischaemia in SLE patients compared to single photon emission computerised tomography (SPECT) and to assess their five-year follow-up. In 50 consecutive SLE patients (mean age 39.2 ± 12.9 years, 90% female), clinical assessment, resting and exercise ECG and echocardiography, multidetector computed tomography - based CACS and SPECT studies (Tc-99m sestamibi) were performed. Patients were then followed for five years. SPECT revealed perfusion defects in 25 (50%) patients; persistent defects in 18 (36%) and exercise-induced defects in seven (14%) subjects. No typical ischaemic heart disease clinical symptoms, signs of ischaemia in resting ECG, or left ventricular contractility impairment in echocardiography were observed. Signs of ischaemia in exercise ECG were found in 17 (34%) patients. The CACS ranged from 1 to 843.2 (median 23.15), and coronary calcifications were observed in 12 (24%) patients. Compared to the SPECT study, exercise ECG had 68% sensitivity and 100% specificity in detecting myocardial ischaemia, while CACS had only 28% sensitivity and 58% specificity. During follow-up, one patient who showed myocardial perfusion defects and the highest calcium score (843.2) at baseline, developed CCS II class symptoms of myocardial ischaemia. Coronary angiography was not performed because of severe anaemia; the patient died three months later. In two other patients with perfusion defects and calcium deposits at baseline, CCS I class symptoms were observed; coronary angiography showed only thin calcified coronary plaques that were haemodynamically insignificant. In about half of relatively young, mostly female, SLE patients, SPECT shows myocardial perfusion defects, with coronary calcifications present in one

  5. Electrocardiographic infarct size assessment after thrombolysis: insights from the Acute Myocardial Infarction STudy ADenosine (AMISTAD) trial.

    Science.gov (United States)

    Barbagelata, Alejandro; Di Carli, Marcelo F; Califf, Robert M; Garg, Jyotsna; Birnbaum, Yochai; Grinfeld, Liliana; Gibbons, Raymond J; Granger, Christopher B; Goodman, Shaun G; Wagner, Galen S; Mahaffey, Kenneth W

    2005-10-01

    Noninvasive methods are needed to evaluate reperfusion success in patients with acute myocardial infarction (MI). The AMISTAD trial was analyzed to compare MI size and myocardial salvage determined by electrocardiogram (ECG) with technetium Tc 99m sestamibi single-photon emission computerized tomography (SPECT) imaging. Of 236 patients enrolled in AMISTAD, 166 (70 %) with no ECG confounding factors and no prior MI were included in this analysis. Of these, group 1 (126 patients, 53%) had final infarct size (FIS) available by both ECG and SPECT. Group 2 (56 patients, 24%) had myocardium at risk, FIS, and salvage index (SI) assessed by both SPECT and ECG techniques. Aldrich/Clemmensen scores for myocardium at risk and the Selvester QRS score for final MI size were used. Salvage index was calculated as follows: SI = (myocardium at risk-FIS)/(myocardium at risk). In group 1, FIS was 15% (6, 24) as measured by ECG and 11% (2, 27) as measured by SPECT. In the adenosine group, FIS was 12% (6, 21) and 11% (2, 22). In the placebo group, FIS was 16.5% (7.5, 24) and 11.5% (3.0, 38.5) by ECG and SPECT, respectively. The overall correlation between SPECT and ECG for FIS was 0.58 (P = .0001): 0.60 in the placebo group (P = .0001) and 0.54 (P = .0001) in the adenosine group. In group 2, myocardium at risk was 23% (17, 30) and 26% (10, 50) with ECG and SPECT, respectively (P = .0066). Final infarct size was 17% (6, 21) and 12% (1, 24) (P < .0001). The SI was 29% (-7, 57) and 46% (15, 79) with ECG and SPECT, respectively (P = .0510). The ECG measurement of infarct size has a moderate relationship with SPECT infarct size measurements in the population with available assessments. This ECG algorithm must further be validated on clinical outcomes.

  6. Effects of diltiazem on myocardial perfusion abnormalities during exercise in patients with hypertrophic cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Sugihara, Hiroki; Taniguchi, Yoko; Ito, Kazuki [Kyoto Prefectural Univ. of Medicine (Japan)] [and others

    1998-12-01

    The effect of diltiazem on myocardial ischemia in patients with hypertrophic cardiomyopathy (HCM) was evaluated by exercise myocardial {sup 201}Tl single photon emission computed tomography (SPECT). Exercise myocardial SPECT was performed before and 8 weeks after oral administration of diltiazem (180 mg/day) in 20 patients with HCM who showed transient perfusion defects on exercise myocardial {sup 201}Tl SPECT under control conditions. SPECT images were divided into 17 segments. The {sup 201}Tl perfusion defects were visually scored and evaluated as the defect score. The transient dilation index was calculated as an index of subendocardial ischemia. Improvement of the defect score was demonstrated in 15 patients after the administration of diltiazem. The mean defect score decreased significantly from 9.90{+-}5.17 to 5.50{+-}4.89 (p<0.0001). Although 16 of 20 patients showed an abnormal transient dilation index before diltiazem treatment, 16 showed improvement and 13 of these normalized after diltiazem therapy. The mean transient dilation index decreased from 1.16{+-}0.10 to 1.02{+-}0.09 (p<0.0001). In conclusion, diltiazem prevents or diminishes myocardial ischemia in patients with HCM. (author)

  7. Cardiology; Cardiologie

    Energy Technology Data Exchange (ETDEWEB)

    Edet-Sanson, A.; Manrique, A.; Hitzel, A.; Vera, P. [Centre Henri Becquerel, 76 - Rouen (France); Kober, F.; Guedj, E.; Quilici, J.; Caus, T.; Mundler, O.; Cozzone, P.J.; Bonnet, J.L.; Bernard, M. [Centre Hospitalier Universitaire de la Timone, 13 - Marseille (France); Daou, D.; Coaguila, C.; Benada, A.; Tawileh, M.; Kaci, N. [Hopital Foch, 92 - Suresnes (France); Vilain, D. [Hopital Lariboisiere AP-HP, 75 - Paris (France); Maskali, F.; Poussier, S.; Boutley, H.; Karcher, G.; Olivier, P.; Py, M. [INSERM U684, Faculte de Medecine de Nancy, 54 (France); Vanhove, C.; Franken, P.R. [AZ-VUB Bruxelles (Belgium); Tran, N.; Groubatch, F. [Centre Hospitalier Universitaire, 54 - Nancy (France)

    2005-11-15

    Spectrometry by nuclear magnetic resonance of the P31 and myocardium viability in correlation with the rest scintigraphy using thallium 201 is developed here, an imaging technique, the pinhole gated-SPECT allows to predict and quantify an experimental model of coronaries occlusion for the rat and is detailed. (N.C.)

  8. Myocardial Ischemia

    Science.gov (United States)

    ... occurs when blood flow to the heart muscle (myocardium) is obstructed by a partial or complete blockage of a coronary artery by a buildup of plaques (atherosclerosis). If the plaques rupture, you can have a heart attack (myocardial infarction). Myocardial ischemia occurs when blood flow ...

  9. SPECT og PET i neurobiologien

    DEFF Research Database (Denmark)

    Paulson, O B; Lassen, N A

    1997-01-01

    PET (positron emission tomography) and SPECT (single photon emission computed tomography) are isotopic methods in which the distribution is registered of radiolabelled tracers given in such small amounts that they are without effect on the organism or the organism's disposal of them. Thus, a series...... of important biological processes in the intact organism can be studied. The methods have been used in many disciplines but in particular for neurobiological research on the brain--e.g., the brain's regional blood circulation and mapping of the brain's functional structure. The methods have also been used...

  10. [Intracoronary and hypodermic injection of granulocyte colony-stimulating factor improved cardiac function in Swine with chronic myocardial ischemia].

    Science.gov (United States)

    Huang, Rong-chong; Yao, Kang; Lu, Hao; Yang, Jun; Shi, Hong-cheng; Zhang, Yi-qi; Huang, Zhe-yong; Zhang, Shu-ning; Yang, Shan; Sun, Ai-jun; Zou, Yun-zeng; Ge, Jun-bo

    2009-08-01

    To compare the efficacy and feasibility between intracoronary and hypodermic injection of granulocyte colony-stimulating factor (G-CSF) on improving cardiac function in a Swine model of chronic myocardial ischemia. Eighteen Swine underwent placement of ameroid constrictor on left circumflex coronary artery. The presence of myocardial ischemia was verified at four weeks after the operation, and the animals were then randomly assigned into three groups (n = 6 each): (1) administration of vehicle (control), (2) hypodermic injection of G-CSF (5 microgxkg(-1)x;d(-1)) for five days (IH), and (3) intracoronary injection of a bonus G-CSF (60 microg/kg) (IC). Coronary angiogram, cardiac MRI, and (18)F-FDG-SPECT/(99m)Tc-SPECT (DISA-SPECT) measurements were performed at pre-administration and at 4 weeks post administration. Global heart function such as left ventricular end-diastolic volume (LVEDV), left ventricular end-systolic volume (LVSDV) and left ventricular ejection fraction (LVEF), myocardial perfusion, myocardial viability and myocardial infarct area were evaluated. Myocardial vWF, Bcl-2 and Bax expressions were detected by Western blot and RT-PCR. MRI data showed that left ventricular dilation and dysfunction were similarly prevented in IH and IC G-CSF treated animals at eight weeks after the operation. SPECT revealed that both IH and IC G-CSF equally improved the regional contractility of chronic myocardial ischemia and increased myocardial viability. Myocardial infarct size was also reduced after both G-CSF treatments as detected by MRI. Intracoronary injection of G-CSF did not lead to angiogenesis in other organs. G-CSF treatments were also associated with a significant reduction in myocardial apoptosis and significant increase in angiogenesis. Both intracoronary and hypodermic injection of G-CSF were safe and feasible and could equally improve cardiac function and increase angiogenesis in this Swine model of chronic myocardial ischemia.

  11. Comparison of 99mTc-sestamibi/18FDG DISA SPECT with PET for the detection of viability in patients with coronary artery disease and left ventricular dysfunction.

    Science.gov (United States)

    Slart, Riemer H J A; Bax, Jeroen J; de Boer, Jaep; Willemsen, Antoon T M; Mook, Piet H; Oudkerk, Matthijs; van der Wall, Ernst E; van Veldhuisen, Dirk J; Jager, Pieter L

    2005-08-01

    Dual-isotope simultaneous acquisition (DISA) single-photon emission computed tomography (SPECT) is an attractive technique as it permits assessment of both myocardial glucose metabolism and perfusion within a single session, but few data on its accuracy for the assessment of viability are available as yet. In the present study, DISA SPECT was compared with positron emission tomography (PET) for the detection of myocardial viability in normal and dysfunctional left ventricular (LV) myocardium. Fifty-eight patients with chronic coronary artery disease and LV dysfunction (LV ejection fraction 33+/-12%) were studied. Patients underwent a 1-day dipyridamole stress 99mTc-sestamibi/18F-fluorodeoxyglucose (18FDG) DISA SPECT and 13N-ammonia/18FDG PET protocol. Within 1 week, resting MRI was performed to assess contractile function. Comparison of PET and SPECT data was performed using both visual and quantitative analysis. The correlation of normalised activities of the flow tracers 99mTc-sestamibi and 13N-ammonia was good (r = 0.82; p DISA SPECT and PET was 82%, with a kappa-statistic of 0.59 (95% CI 0.53-0.64), without a significant difference; in dysfunctional segments only, the agreement was 82%, with a kappa-statistic of 0.63 (95% CI 0.56-0.70), without a significant difference. When the DISA SPECT data were analysed visually, the agreement between DISA SPECT and PET was 83%, with a kappa-statistic of 0.58 (95% CI 0.52-0.63), without a significant difference. Moreover, there was no significant difference between visual and quantitative DISA SPECT analysis for the detection of viability. This study shows an overall good agreement between 99mTc-sestamibi/18FDG DISA SPECT and PET for the assessment of myocardial viability in patients with severe LV dysfunction. Quantitative or visual analysis of the SPECT data did not influence the agreement with PET, suggesting that visual assessment may be sufficient for clinical purposes.

  12. Comparison of the prognostic value of regadenoson and adenosine myocardial perfusion imaging.

    Science.gov (United States)

    Farzaneh-Far, Afshin; Shaw, Linda K; Dunning, Allison; Oldan, Jorge D; O'Connor, Christopher M; Borges-Neto, Salvador

    2015-08-01

    Regadenoson is now widely used in single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI). However, the prognostic value of abnormal stress perfusion findings with regadenoson vs adenosine are unclear. The aim of this study was to evaluate the prognostic value of regadenoson SPECT and to compare it to that of adenosine SPECT. 3698 consecutive patients undergoing either adenosine or regadenoson SPECT were assessed at 1 year for the endpoints of cardiovascular death and a composite endpoint of cardiovascular death or MI. Weighted Cox proportional hazards regression modeling with the inverse probability weighted (IPW) estimators method adjusting to propensity for agent was used to account for differences in baseline characteristics. Patients undergoing adenosine SPECT MPI had a significantly higher prevalence of smoking history, diabetes, hypertension, and prior myocardial infarction (P regadenoson SPECT MPI is a significant predictor of events and provides incremental prognostic information beyond basic clinical variables. We have shown for the first time that use of regadenoson vs adenosine as stress agent does not modify the prognostic significance of SSS. Similar findings were seen with SDS.

  13. Acceleration of Monte Carlo-based scatter compensation for cardiac SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Sohlberg, A; Watabe, H; Iida, H [National Cardiovascular Center Research Institute, 5-7-1 Fujishiro-dai, Suita City, 565-8565 Osaka (Japan)], E-mail: antti.sohlberg@hermesmedical.com

    2008-07-21

    Single proton emission computed tomography (SPECT) images are degraded by photon scatter making scatter compensation essential for accurate reconstruction. Reconstruction-based scatter compensation with Monte Carlo (MC) modelling of scatter shows promise for accurate scatter correction, but it is normally hampered by long computation times. The aim of this work was to accelerate the MC-based scatter compensation using coarse grid and intermittent scatter modelling. The acceleration methods were compared to un-accelerated implementation using MC-simulated projection data of the mathematical cardiac torso (MCAT) phantom modelling {sup 99m}Tc uptake and clinical myocardial perfusion studies. The results showed that when combined the acceleration methods reduced the reconstruction time for 10 ordered subset expectation maximization (OS-EM) iterations from 56 to 11 min without a significant reduction in image quality indicating that the coarse grid and intermittent scatter modelling are suitable for MC-based scatter compensation in cardiac SPECT. (note)

  14. Recent advances in the development of PET/SPECT probes for atherosclerosis imaging

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, Yoich; Kuge, Yuji [Hokkaido University, Sapporo (Japan)

    2016-12-15

    The rupture of vulnerable atherosclerotic plaques and subsequent thrombus formation are the major causes of myocardial and cerebral infarction. Accordingly, the detection of vulnerable plaques is important for risk stratification and to provide appropriate treatment. Inflammation imaging using 2-deoxy-2-[{sup 18}F]fluoro-D-glucose ({sup 18}F-FDG) has been most extensively studied for detecting vulnerable atherosclerotic plaques. It is of great importance to develop PET/SPECT probes capable of specifically visualizing the biological molecules involved in atherosclerotic plaque formation and/or progression. In this article, we review recent advances in the development of PET/SPECT probes for visualizing atherosclerotic plaques and their application to therapy monitoring, mainly focusing on experimental studies.

  15. SPECT in the diagnosis of hepatic hemangioma

    Energy Technology Data Exchange (ETDEWEB)

    Brunetti, J.C.; Van Heertum, R.L.; Yudd, A.P.

    1985-05-01

    Tc99m labeled red blood cell blood flow and delayed static blood pool imaging is widely accepted as a reliable, accurate method for the diagnosis of hepatic hemangiomata. The purpose of this study is to assess the relative value of SPECT blood pool imaging in the evaluation of hepatic hemangionata. A total of 68 patients, including 21 patients with proven hepatic cavernous hemangiomas, were studied using both planar and SPECT imaging techniques. All patients underwent multi-phase evaluation which included a hepatic flow study, immediate planar images of the liver, followed by a 360/sup 0/ tomographic (SPECT) study and subsequent 60 minute delayed static planar hepatic blood pool images. All 21 patients with proven hepatic hemangiomas had a positive SPECT exam and 17 of the 21 (81%) patients had a positive planar exam. In the 21 patients, there were a total of 36 hemangiomas ranging in size from .7 cm to 13 cm. The SPECT imaging technique correctly identified all 36 lesions (100%) where as planar imaging detected 25 of the 36 lesions (69.4%). In all the remaining patients (10-normal, 17-metastatic disease, 12-hepatocellular disease, 6-hepatoma, 2-liver cysts), both the planar and SPECT imaging techniques were interpreted as showing no evidence of focal sequestration of red blood cells. SPECT hepatic blood pool imaging represents an improvement in the evaluation of hepatic hemangioma as a result of a reduction in imaging time (less than thirty minutes), improved spatial resolution and greater overall accuracy.

  16. Detection of myocardial perfusion abnormalities: standard dual-source coronary computed tomography angiography versus rest/stress technetium-99m single-photo emission CT.

    Science.gov (United States)

    Cheng, W; Zeng, M; Arellano, C; Mafori, W; Goldin, J; Krishnam, M; Ruehm, S G

    2010-08-01

    We compared coronary dual-source computed tomography angiography (corDSCTA) with technetium-99m single-photon emission computed tomography (SPECT) for the detection of myocardial perfusion abnormalities. Fifty-five consecutive patients underwent both gated myocardial perfusion SPECT and corDSCTA, the latter during a single arterial-phase injection of contrast agent. The perfusion defects visualised by corDSCTA correlated with the findings of rest/stress SPECT. Abnormal findings on stress SPECT, which were due to either ischaemia or infarct, were found in 24 patients. In comparison to SPECT at rest, corDSCTA detected perfusion defects with a sensitivity and specificity of 100% and 78%, respectively. Compared to SPECT at stress, the sensitivity and specificity values of corDSCTA were 83.3% and 90.3%, respectively. On corDSCTA , the average attenuation values of perfusion defects that corresponded to chronic infarcts (-8.5+/-22.2 HU) were significantly lower (p = 0.002) than those of non-infarct-related perfusion defects (43.1+/-17.5 HU). Using rest/stress SPECT is the gold standard for the diagnosis of myocardial ischaemia, corDSCTA was able to diagnose ischaemic disease (defined as the presence of high-grade stenotic CAD (>or=50% luminal narrowing)) with a sensitivity and specificity of 59% and 89%, respectively, in patients with no known history of myocardial infarction (n = 4). Thus, corDSCTA may serve as a diagnostic tool for the detection of perfusion abnormalities (first) visualised by SPECT. There appears to be a limited correlation between coronary stenotic disease and SPECT findings.

  17. Exercise myocardial perfusion scintigraphy is useful for evaluating myocardial ischemia even in the elderly

    Energy Technology Data Exchange (ETDEWEB)

    Kurata, Chinori; Uehara, Akihiko; Sugi, Toshihiko; Yamazaki, Keisuke [Hamamatsu Univ. School of Medicine, Shizuoka (Japan); Tawarahara, Kei; Mikami, Tadashi; Matoh, Fumitaka; Odagiri, Keiichi

    2000-06-01

    Pharmacologic stress testing is recommended to elderly patients as a valuable alternative to exercise testing. We examined whether exercise testing is as useful for evaluating myocardial ischemia in the elderly as in the young. The consecutive 1,508 patients who underwent exercise {sup 201}Tl single-photon emission computed tomography (SPECT) were divided into six age groups: 6-29 years (n=56), 30-44 (n=143), 45-54 (n=311), 55-64 (n=498), 65-74 (n=402), and 75-88 (n=98). Both heart rate and rate-pressure product at peak exercise were significantly lower in patients aged 75-88 than in the other five groups. The frequency of ischemic ST depression was higher in patients aged 75-88 than in those aged 6-74, although the difference was not significant. Moreover, the frequency of {sup 201}Tl transient defect was significantly higher in patients aged 75-88 than in those aged 6-74. On the other hand, the sensitivity of ischemic ST depression for {sup 201}Tl transient defect was similar among the six groups, but the specificity was significantly lower in patients aged 75-88 than in those aged 6-74. In conclusion, exercise {sup 201}Tl SPECT is useful for evaluating myocardial ischemia even in the elderly, but exercise electrocardiography has limitations such as lower specificity in the elderly than {sup 201}Tl SPECT. (author)

  18. Crossed cerebellar hyperperfusion in brain perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Jinnouchi, Seishi; Nagamachi, Shigeki; Nishii, Ryuuichi; Futami, Shigemi; Tamura, Shozo [Miyazaki Medical Coll., Kiyotake (Japan); Kawai, Keiichi

    2000-10-01

    Crossed cerebellar diaschisis is a well-known brain SPECT finding in stroke patients. Few reports, however, have described supratentorial and contralateral cerebellar hyperperfusion (crossed cerebellar hyperperfusion, CCH). We assessed the incidence of CCH in 33 patients with cerebral hyperperfusion. Brain SPECT showed CCH in five patients out of 20 epilepsy and three of 13 patients with acute encephalitis. These eight patients with CCH had recent epileptic attack. CCH was found in ECD SPECT as well as HM-PAO. The contralateral cerebellar activity correlated with the cerebral activity in patients with CCH. CCH would have a relation with supratentrial hyperfunction in epilepsy and acute encephalitis. (author)

  19. [Effects of intracoronary autologous bone marrow mononuclear cells transplantation in patients with anterior myocardial infarction].

    Science.gov (United States)

    Wang, Wei-min; Sun, Ning-ling; Liu, Jian; Zhang, Ping; Liu, Kai-yan; Wang, Qian; Yang, Song-na; Wang, Su-qin; Zang, Yue; Guo, Ji-hong

    2006-02-01

    To investigate the efficacy of intracoronary transfer of autologous bone marrow mononuclear cells (ABMMNCs) to patients with myocardial infarction (MI) on left ventricular function and myocardial perfusion. Thirty-five patients with MI (> 4 weeks) were enrolled in this prospective, open-labeled study (20 patients in cell transplantation group; 15 patients in control group). All patients were treated by standard drug therapy and percutaneous coronary intervention (PCI). Baseline and 3 months follow-up evaluations included complete clinical and laboratory examinations, six minutes walk test, echocardiography, Dual-isotope simultaneous acquisition single photon emission computed tomography (DISA-SPECT) and cardiac magnetic resonance imaging (MRI). Baseline parameters were similar between the two groups. NYHA classification and six minutes walk test at 3 months follow-up were also similar between the two groups. However, left ventricular ejection fraction (LVEF) determined by echocardiography and DISA-SPECT was significantly higher; regional wall motion measured by echocardiography and cardiac MRI, myocardial viability and myocardial perfusion in the infarct zone assessed by DISA-SPECT were all significantly improved than before transplantation and than that in control group at 3 months follow-up. Our results indicate that intracoronary transplantation of ABMMNCs could improve the left ventricular systolic function and beneficially affect myocardial perfusion up to 3 months post transplantation in patients with myocardial infarction.

  20. Single Photon Emission Computed Tomography (SPECT)

    Science.gov (United States)

    ... comfortable shoes if you will have an exercise stress test. What happens during cardiac SPECT? A doctor and nuclear medicine technologist usually perform the scan in a hospital or clinic using special equipment. The technician will ...

  1. SPECT assay of radiolabeled monoclonal antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Jaszczak, R.J.

    1992-02-01

    The long-term goal of this research project is to develop methods to improve the utility of single photon emission computed tomography (SPECI) to quantify the biodistribution of monoclonal antibodies (MoAbs) labeled with clinically relevant radionuclides ({sup 123}I, {sup 131}I, and {sup 111}In) and with another radionuclide,{sup 211}At, recently used in therapy. We describe here our progress in developing quantitative SPECT methodology for {sup 111}In and {sup 123}I. We have focused our recent research thrusts on the following aspects of SPECT: (1) The development of improved SPECT hardware, such as improved acquisition geometries. (2) The development of better reconstruction methods that provide accurate compensation for the physical factors that affect SPECT quantification. (3) The application of carefully designed simulations and experiments to validate our hardware and software approaches.

  2. Hypoglycaemic hemiplegia: a repeat SPECT study.

    Science.gov (United States)

    Shintani, S; Tsuruoka, S; Shiigai, T

    1993-01-01

    During a hypoglycaemic right hemiplegia induced by a deliberate overdose of oral hypoglycaemics, brain CT and angiography revealed no abnormalities. SPECTs made one day and six days later showed relative hypoperfusion in the left hemisphere. Repeat SPECT study suggested that the left hemisphere was more vulnerable than the right in the cerebral blood perfusion. This vulnerability might provoke the right hemiplegia in a critical condition, such as severe hypoglycaemia. Images PMID:8509788

  3. Brain SPECT imaging in temporal lobe epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Krausz, Y.; Yaffe, S.; Atlan, H. (Hadassah Univ. Hospital, Jerusalem (Israel). Dept. of Medical Biophysics and Nuclear Medicine); Cohen, D. (Hadassah Univ. Hospital, Jerusalem (Israel). Dept. of Radiology); Konstantini, S. (Hadassah Univ. Hospital, Jerusalem (Israel). Dept. of Neurosurgery); Meiner, Z. (Hadassah Univ. Hospital, Jerusalem (Israel). Dept. of Neurology)

    1991-06-01

    Temporal lobe epilepsy is diagnosed by clinical symptoms and signs and by localization of an epileptogenic focus. A brain SPECT study of two patients with temporal lobe epilepsy, using {sup 99m}Tc-HMPAO, was used to demonstrate a perfusion abnormality in the temporal lobe, while brain CT and MRI were non-contributory. The electroencephalogram, though abnormal, did not localize the diseased area. The potential role of the SPECT study in diagnosis and localization of temporal lobe epilepsy is discussed. (orig.).

  4. Pseudodefects in SPET myocardium imaging after placement of a defibrillator patch electrode; Pseudodefekte bei der Myokard-SPECT durch implantierte Defibrillator-Patches: Phantommessungen mit SPECT und PET

    Energy Technology Data Exchange (ETDEWEB)

    Buchert, R. [Universitaetskrankenhaus Eppendorf, Hamburg (Germany). Abt. fuer Nuklearmedizin der Radiologischen Klinik; Rickers, C. [Universitaetskrankenhaus Eppendorf, Hamburg (Germany). Abt. Kardiologie der Klinik fuer Innere Medizin; Fuchs, C. [Universitaetskrankenhaus Eppendorf, Hamburg (Germany). Abt. fuer Nuklearmedizin der Radiologischen Klinik; Nienaber, C.A. [Universitaetskrankenhaus Eppendorf, Hamburg (Germany). Abt. Kardiologie der Klinik fuer Innere Medizin; Luebeck, M. [Universitaetskrankenhaus Eppendorf, Hamburg (Germany). Abt. fuer Nuklearmedizin der Radiologischen Klinik

    1996-12-01

    Aim and Methods: In order to estimate the effect of an epicardial or subcutan defibrillator patch electrode on the imaging of myocardium with SPET and PET we performed measurements with a body phantom and two different patch electrodes. Results: We found that in {sup 201}Tl-SPET with epicardial placing one electrode causes significant pseudodefects, which might lead to the impression of an infarction (`pseudoinfarction`), particularly in the case of reduced myocardial wall thickness. Measurements with {sup 99m}Tc show the same pseudodefects. In case of subcutaneous placing the electrodes are much less likely to cause relevant absorption effects. With PET even epicardially placed both patch electrodes do not produce pseudodefects. Therefore the risk of false-positive findings is very small with PET. Conclusion: In order to avoid false positive findings in cardiovascular nuclear medicine caused by defibrillator patch electrodes, patients with patch electrodes should be referred to PET, if available. (orig.) [Deutsch] Ziel und Methoden: Um den Effekt eines epikardial oder subkutan implantierten Defibrillator-Patches bei der nuklearmedizinischen Herzdiagnostik mittels SPECT und PET abzuschaetzen, wurden Messungen an einem Koerperphantom mit zwei verschiedenen Patchelektroden durchgefuehrt. Ergebnisse: Es zeigte sich, dass bei der {sup 201}Tl-SPECT bei epikardialer Plazierung eine der beiden Elektroden Pseudodefekte verursacht, die insbesondere im Falle duennwandiger Herzen die Beurteilung erschweren oder sogar zu falsch-positiven Befunden (`Pseudoinfarkte`) fuehren koennen. Bei Messungen mit {sup 99m}Tc findet man dieselben Pseudodefekte in nahezu gleicher Auspraegung. Im Falle subkutaner Plazierung sind beide Elektroden sowohl bei der {sup 201}Tl-SPECT als auch bei der {sup 99m}Tc-SPECT unkritisch. Bei der PET stellen die untersuchten Patchelektroden selbst bei epikardialer Plazierung keine erkennbare Stoerung dar, so dass hier die Gefahr eines falsch

  5. SPECT assay of radiolabeled monoclonal antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Jaszczak, R.J.

    1992-02-01

    The accurate determination of the biodistribution of radiolabeled monoclonal antibodies (MoAbs) is important for calculation of dosimetry and evaluation of pharmacokinetic variables such as antibody dose and route of administration. The hypothesis of this application is that the biodistribution of radiolabeled monoclonal antibodies (MoAbs) can be quantitatively determined using single photon emission computed tomography (SPECT). The major thrusts during the third year include the continued development and evaluation of improved 3D SPECT acquisition and reconstruction approaches to improve quantitative imaging of radiolabeled monoclonal antibodies (MoAbs), and the implementation and evaluation of algorithms to register serial SPECT image data sets, or to register 3D SPECT images with 3D image data sets acquired from positron emission tomography (PEI) and magnetic resonance images (MRI). The research has involved the investigation of statistical models and iterative reconstruction algorithms that accurately account for the physical characteristics of the SPECT acquisition system. It is our belief that SPECT quantification can be improved by accurately modeling the physical processes such as attenuation, scatter, geometric collimator response, and other factors that affect the measured projection data.

  6. SPECT/CT diagnostics for skeletal infections; SPECT/CT-Infektdiagnostik am Skelett

    Energy Technology Data Exchange (ETDEWEB)

    Klaeser, B.; Spanjol, M.; Krause, T. [Inselspital Bern, Universitaetsklinik fuer Nuklearmedizin, Bern (Switzerland)

    2012-07-15

    Skeletal infections are often a diagnostic and clinical challenge. Nuclear imaging modalities used in the diagnostic workup of acute and chronic skeletal infections include three-phase bone scintigraphy and scintigraphy with labelled leucocytes. The introduction of hybrid technologies, such as single photon emission computed tomography/computed tomography (SPECT/CT) has dramatically changed nuclear medical imaging of infections. In general SPECT/CT leads to a considerably more accurate diagnosis than planar or SPECT imaging. Given the integrated acquisition of metabolic, functional and morphological information, SPECT/CT has increased in particular the specificity of three-phase skeletal scanning and scintigraphy with labeled leucocytes. (orig.) [German] Knoecherne Infekte stellen nicht selten eine diagnostische und klinische Herausforderung dar. Nuklearmedizinische Standardverfahren fuer die Diagnostik akuter und chronischer Knocheninfekte sind die Mehrphasenskelettszintigraphie und die Infektszintigraphie mit markierten Leukozyten. Die Einfuehrung von Hybridtechnologien wie der SPECT/CT hat die nuklearmedizinische Infektbildgebung tiefgreifend veraendert. Die SPECT/CT erlaubt bei der Frage nach Knocheninfekten insgesamt eine wesentlich genauere Beurteilung als planare Aufnahmen und SPECT. Die integrierte Akquisition von metabolischer, funktioneller und topographisch-morphologischer Information mit SPECT/CT steigerte insbesondere die Spezifitaet der Mehrphasenskelettszintigraphie und der Infektszintigraphie mit markierten Leukozyten. (orig.)

  7. SPECT/CT - Technical aspects and optimization possibilities; SPECT/CT - Technische Aspekte und Optimierungsmoeglichkeiten

    Energy Technology Data Exchange (ETDEWEB)

    Roemer, W. [Klinikum Passau, Klinik fuer Nuklearmedizin, Passau (Germany)

    2012-07-15

    In contrast to positron emission tomography/computed tomography (PET/CT), the currently available single photon emission computed tomography/computed tomography (SPECT/CT) systems are very heterogeneous. On the side of the gamma cameras, dual-head systems are established, which are not very different from one manufacturer to the other. For the CT component, there are low dose tubes on the one side and flat detector-based cone beam CT and multislice-CT on the other. The CT image data can be used for anatomic correlation of suspicious findings as well as for attenuation correction of SPECT data. Attenuation correction enables on the one hand enhancement of SPECT image quality and on the other hand quantification of the radioactivity concentration becomes possible. Modern iterative reconstruction algorithms allow scatter correction and attenuation correction of SPECT data using the density values from CT. It still has to be shown to what extent attenuation-corrected whole body SPECT/CT studies will be able to improve the sensitivity of scintigraphy studies. As SPECT/CT primarily aims at morphologic correlation and not detection of additional lesions, an attempt should be made to balance the necessary anatomic information and the additional radiation exposure. Besides SPECT-guided CT all technical possibilities for dose reduction should be exhausted. (orig.) [German] Im Gegensatz zur Positronenemissionstomographie/Computertomographie (PET/CT) sind die auf dem Markt angebotenen Single-photon-emission-computed-tomography/CT(SPECT/CT)-Systeme sehr heterogen. Auf der Seite der Gammakameras sind Zweikopfsysteme etabliert, die sich bei den verschiedenen Wettbewerbern nur unwesentlich unterscheiden. Hingegen reicht bei der CT-Komponente die Palette von der einfachen Niedrigdosisroentgenroehre ueber die flachdetektorbasierte Cone-beam-CT-Technologie bis hin zum Mehrzeilenspiral-CT. Die CT-Bilddaten werden dabei zum einen zur anatomischen Korrelation funktionell auffaelliger

  8. Improved Benefit of SPECT/CT Compared to SPECT Alone for the Accurate Localization of Endocrine and Neuroendocrine Tumors

    Directory of Open Access Journals (Sweden)

    Gonca G. Bural

    2012-12-01

    Full Text Available Objective: To assess the clinical utility of SPECT/ CT in subjects with endocrine and neuroendocrine tumors compared to SPECT alone. Material and Methods: 48 subjects (31 women;17 men; mean age 54±11 with clinical suspicion or diagnosis of endocrine and neuroendocrine tumor had 50 SPECT/CT scans (32 Tc-99m MIBI, 5 post treatment I-131, 8 In-111 Pentetreotide, and 5 I-123 MIBG. SPECT alone findings were compared to SPECT/CT and to pathology or radiological follow up. Results: From the 32 Tc-99m MIBI scans, SPECT accurately localized the lesion in 22 positive subjects while SPECT/CT did in 31 subjects. Parathyroid lesions not seen on SPECT alone were smaller than 10 mm. In five post treatment I-131 scans, SPECT alone neither characterized, nor localized any lesions accurately. SPECT/CT revealed 3 benign etiologies, a metastatic lymph node, and one equivocal lesion. In 8 In-111 Pentetreotide scans, SPECT alone could not localize primary or metastatic lesions in 6 subjects all of which were localized with SPECT/CT. In five I-123 MIBG scans, SPECT alone could not detect a 1.1 cm adrenal lesion or correctly characterize normal physiologic adrenal uptake in consecutive scans of the same patient with prior history of adrenelectomy, all of which were correctly localized and characterized with SPECT/CT. Conclusion: SPECT/CT is superior to SPECT alone in the assessment of endocrine and neuroendocrine tumors. It is better in lesion localization and lesion characterization leading to a decrease in the number of equivocal findings. SPECT/CT should be included in the clinical work up of all patients with diagnosis or suspicion of endocrine and neuroendocrine tumors. (MIRT 2012;21:91-96

  9. A quantitative reconstruction software suite for SPECT imaging

    Science.gov (United States)

    Namías, Mauro; Jeraj, Robert

    2017-11-01

    Quantitative Single Photon Emission Tomography (SPECT) imaging allows for measurement of activity concentrations of a given radiotracer in vivo. Although SPECT has usually been perceived as non-quantitative by the medical community, the introduction of accurate CT based attenuation correction and scatter correction from hybrid SPECT/CT scanners has enabled SPECT systems to be as quantitative as Positron Emission Tomography (PET) systems. We implemented a software suite to reconstruct quantitative SPECT images from hybrid or dedicated SPECT systems with a separate CT scanner. Attenuation, scatter and collimator response corrections were included in an Ordered Subset Expectation Maximization (OSEM) algorithm. A novel scatter fraction estimation technique was introduced. The SPECT/CT system was calibrated with a cylindrical phantom and quantitative accuracy was assessed with an anthropomorphic phantom and a NEMA/IEC image quality phantom. Accurate activity measurements were achieved at an organ level. This software suite helps increasing quantitative accuracy of SPECT scanners.

  10. Assessment of left ventricular performance by ECG-gated SPECT. Comparison with magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Tadamura, Eiji; Inubushi, Masayuki; Kubo, Shigeto; Matsumoto, Keiichi; Yokoyama, Hiroshi; Fujita, Toru; Konishi, Junji [Kyoto Univ. (Japan). Faculty of Medicine

    1999-10-01

    In the measurement of a left ventricular volume, MIBI-QGS was compared with MRI. Because it became clear by the experiment using phantom that a volume calculated with QGS was smaller than the actual volume, data of clinical study were corrected. Subjects were 20 patients with coronary artery disease. Fourteen patients had anamnesis of myocardial infarct. ECG-gated SPECT was performed one hour after intravenous injection of MIBI (600 MBq) in rest. End diastolic volume (EDV), end systolic volume (ESV) and ejection fraction (EF) were calculated using QGS. Cine-MR image was obtained by using MR system of 1.5 Tesla within 1 week after SPECT. A condition was as follows; segmented k-space gradient echo with view sharing, TR=11 ms, TE=1.4 ms, flip angle 20 degree, field of view 32 cm, matrix 256 x 196, 8 lines per segment. LVEF, ESV and EF were analysed by Bland-Altman method, and the difference between MIBI-gated-SPECT and MRI was no problem. Horizontal dislocation image and vertical major axis dislocation image were provided. Minor axis crossing images of 10-12 slice were also filmed in order to cover all left ventricles. As a result, availability of MIBI-QGS became clear. Some factors which produces the measurement error are examined. (K.H.)

  11. Imaging techniques in nuclear cardiology for the assessment of myocardial viability.

    Science.gov (United States)

    Slart, Riemer H J A; Bax, Jeroen J; van Veldhuisen, Dirk J; van der Wall, Ernst E; Dierckx, Rudi A J O; Jager, Pieter L

    2006-02-01

    The assessment of myocardial viability has become an important aspect of the diagnostic and prognostic work-up of patients with ischemic cardiomyopathy. Although revascularization may be considered in patients with sufficient viable myocardium, patients with predominantly scar tissue should be treated medically. Patients with left ventricular dysfunction who have viable myocardium are the patients at highest risk because of the potential for ischemia but at the same time benefit most from revascularization. It is important to identify viable myocardium in these patients, and radionuclide myocardial scintigraphy is an excellent tool for this. Single-photon emission computed tomography perfusion scintigraphy (SPECT), whether using (201)thallium, (99m)Tc-sestamibi, or (99m)Tc-tetrofosmin, in stress and/or rest protocols, has consistently been shown to be an effective modality for identifying myocardial viability and guiding appropriate management. Metabolic and perfusion imaging with positron emission tomography (PET) radiotracers frequently adds additional information and is a powerful tool for predicting which patients will have an improved outcome from revascularization. New techniques in the nuclear cardiology field, like attenuation corrected SPECT, dual isotope simultaneous acquisition (DISA) SPECT and gated FDG PET are promising and will further improve the detection of myocardial viability. Also the combination of multislice computed tomography scanners with PET opens possibilities of adding coronary calcium scoring and non-invasive coronary angiography to myocardial perfusion imaging and quantification. Evaluation of the clinical role of these creative new possibilities warrants investigation.

  12. Transient Ischemic Dilation of the Left Ventricle on SPECT: Correlation with Findings at Coronary CT Angiography.

    Science.gov (United States)

    Halligan, William T; Morris, Pamela B; Schoepf, U Joseph; Mischen, Blaine T; Spearman, James V; Spears, J Reid; Blanke, Philipp; Cho, Young Jun; Silverman, Justin R; Chiaramida, Salvatore A; Ebersberger, Ullrich

    2014-06-01

    Transient ischemic dilation (TID) in the setting of abnormal stress-rest cardiac SPECT myocardial perfusion imaging (MPI) has been linked with increased cardiovascular risk. However, the significance of TID in the setting of an otherwise normal SPECT MPI study has not been clearly established. In this study, cardiac CT was used to evaluate the prevalence of atherosclerotic lesions and the severity of coronary artery stenosis in patients with TID of the left ventricle with or without associated myocardial perfusion defects on SPECT MPI. The study population consisted of 1,553 consecutive patients who had undergone both cardiac CT and SPECT MPI within 1 mo between January 1, 2006, and September 1, 2011. Patients included in the study group had a pathologic TID value defined as ≥1.18 for men and ≥1.22 for women. Coronary CT angiography was used to evaluate each coronary segment for the presence and composition of atherosclerotic plaque and the degree of coronary stenosis. TID-positive patients were compared with a 2:1 risk-factor-matched-pair control cohort without TID. TID was identified in 30 patients who were compared with TID-negative risk-factor-matched controls (n = 60). When compared with the TID-negative control cohort, TID-positive patients had no significant differences in the presence and extent of atherosclerosis, the degree of coronary artery stenosis, or the calcium score at cardiac CT. Similarly, there were no significant differences in these CT measures in TID-positive patients with a normal perfusion study (n = 20) when compared with TID-negative patients with a normal perfusion study (n = 48). In addition, there was no significant difference in the incidence of major adverse cardiac events when comparing both the TID-positive patients and the TID-negative control cohort and when comparing patients who were TID-positive with normal perfusion with patients who were TID-negative with normal perfusion. The presence of TID with an otherwise normal

  13. Prediction of functional recovery after revascularization in patients with chronic ischaemic left ventricular dysfunction : head-to-head comparison between Tc-99m-sestamibi/F-18-FDG DISA SPECT and N-13-ammonia/F-18-FDG PET

    NARCIS (Netherlands)

    Slart, Riemer H. J. A.; Bax, Jeroen J.; van Veldhuisen, Dirk J.; van der Wall, Ernst E.; Irwan, Roy; Sluiter, Wim J.; Dierckx, Rudi A.; de Boer, Jaep; Jager, Pieter L.

    Purpose: F-18-FDG PET is an important modality for myocardial viability assessment in patients with left ventricular (LV) dysfunction. Dual-isotope simultaneous acquisition (DISA) SPECT may be an alternative to PET. The aim of this study was to compare the diagnostic performance of PET and DISA

  14. Machine-learning model observer for detection and localization tasks in clinical SPECT-MPI

    Science.gov (United States)

    Parages, Felipe M.; O'Connor, J. Michael; Pretorius, P. Hendrik; Brankov, Jovan G.

    2016-03-01

    In this work we propose a machine-learning MO based on Naive-Bayes classification (NB-MO) for the diagnostic tasks of detection, localization and assessment of perfusion defects in clinical SPECT Myocardial Perfusion Imaging (MPI), with the goal of evaluating several image reconstruction methods used in clinical practice. NB-MO uses image features extracted from polar-maps in order to predict lesion detection, localization and severity scores given by human readers in a series of 3D SPECT-MPI. The population used to tune (i.e. train) the NB-MO consisted of simulated SPECT-MPI cases - divided into normals or with lesions in variable sizes and locations - reconstructed using filtered backprojection (FBP) method. An ensemble of five human specialists (physicians) read a subset of simulated reconstructed images, and assigned a perfusion score for each region of the left-ventricle (LV). Polar-maps generated from the simulated volumes along with their corresponding human scores were used to train five NB-MOs (one per human reader), which are subsequently applied (i.e. tested) on three sets of clinical SPECT-MPI polar maps, in order to predict human detection and localization scores. The clinical "testing" population comprises healthy individuals and patients suffering from coronary artery disease (CAD) in three possible regions, namely: LAD, LcX and RCA. Each clinical case was reconstructed using three reconstruction strategies, namely: FBP with no SC (i.e. scatter compensation), OSEM with Triple Energy Window (TEW) SC method, and OSEM with Effective Source Scatter Estimation (ESSE) SC. Alternative Free-Response (AFROC) analysis of perfusion scores shows that NB-MO predicts a higher human performance for scatter-compensated reconstructions, in agreement with what has been reported in published literature. These results suggest that NB-MO has good potential to generalize well to reconstruction methods not used during training, even for reasonably dissimilar datasets (i

  15. [Comparison of low-dose dobutamine echocardiography and dual-isotope emission simultaneous myocardial perfusion acquisition for myocardial viability assessment].

    Science.gov (United States)

    Fang, Li-Gang; Chen, Li-Bo; Li, Fang; Zhu, Wen-Ling; Fang, Quan

    2007-04-01

    To compare the value of low-dose dobutamine echocardiography (LDDE) and dual-isotope emission simultaneous myocardial perfusion acquisition (technetium-99-m-tetrofosmin/fluorine 18-fluorodeoxy-glucose) single-photon emission computed tomography (DISA-SPECT) for myocardial viability assessment in patients with acute myocardial infarction (MI). LDDE and DISA-SPECT were performed in 44 patients within 5-10 days after onset of first acute MI and percutaneous coronary intervention was made thereafter. A 16-segment semi-quantitative scoring model was adopted for both techniques. Wall motion improvement at follow-up (3 months after acute MI) compared with baseline before dobutamine infusion derived from two dimensional images was used as golden criteria for myocardial viability. The sensitivity, specificity, diagnostic accuracy, positive and predictive values for identification of viable myocardium were 77%, 82%, 79%, 82% and 77%, respectively by LDDE and 85%, 62%, 74%, 71% and 79%, respectively by DISA. No difference was found between LDDE and DISA for identifying viable myocardium in hypokinetic segments (74.1% vs. 77.6%, P > 0.05) but less viable myocardium was detected by LDDE than DISA in akinetic segments (29% vs. 53%, P DISA compared to LDDE. Combined use of the two techniques could improve viable myocardium detection in patients with acute MI.

  16. A model that accounts for the interdependence of extent and severity in the automatic evaluation of myocardial defects

    DEFF Research Database (Denmark)

    El-Ali, Henrik Hussein; Palmer, John; Edenbrandt, Lars

    2006-01-01

    The extent and severity are two important parameters when describing a regional defect in myocardial single-photon emission computed tomography (SPECT) perfusion imaging. Intuitively, these two parameters should be independent of each other, but we have shown in a previous study that there is an ...

  17. Assessment of myocardial washout of Tc-99m-sestamibi in patients with chronic heart failure. Comparison with normal control

    Energy Technology Data Exchange (ETDEWEB)

    Kumita, Shin-ichiro; Seino, Yoshihiko; Cho, Keiichi; Nakajo, Hidenobu; Toba, Masahiro; Fukushima, Yoshimitsu; Takano, Teruo; Kumazaki, Tatsuo [Nippon Medical School, Tokyo (Japan); Okamoto, Noriake [Bristol-Myers Squibb K.K., Tokyo (Japan)

    2002-06-01

    In contrast to {sup 201}TlCl, {sup 99m}Tc-sestamibi shows very slow myocardial clearance after its initial myocardial uptake. In the present study, myocardial washout of {sup 99m}Tc-sestamibi was calculated in patients with non-ischemic chronic heart failure (CHF) and compared with biventricular parameters obtained from first-pass and ECG-gated myocardial perfusion SPECT data. After administration of {sup 99m}Tc-sestamibi, 25 patients with CHF and 8 normal controls (NC) were examined by ECG-gated myocardial perfusion SPECT and planar data acquisition in the early and delayed (interval of 3 hours) phase. Left ventricular ejection fraction (LVEF, %), peak filling rate (PFR, sec{sup -1}), end-diastolic volume (LVEDV, ml) and end-systolic volume (LVESV, ml) were automatically calculated from the ECG-gated SPECT data. Myocardial washout rates over 3 hours were calculated from the early and delayed planar images. Myocardial washout rates in the CHF group (39.6{+-}5.2%) were significantly higher than those in the NC group (31.2{+-}5.5%, p<0.01). The myocardial washout rates for the 33 subjects showed significant correlations with LVEF (r=-0.61, p<0.001), PFR (r=-0.47, p<0.01), LVEDV (r=0.45, p<0.01) and LVESV (r=0.48, p<0.01). The myocardial washout rate of {sup 99m}Tc-sestamibi is considered to be a novel marker for the diagnosis of myocardial damage in patients with chronic heart failure. (author)

  18. SPECT in psychiatry; Die Bedeutung der Hirn-SPECT in der Psychiatrie

    Energy Technology Data Exchange (ETDEWEB)

    Kasper, S. [Universitaetsklinik fuer Psychiatrie, Wien (Austria); Gruenwald, F. [Bonn Univ. (Germany). Klinik fuer Nuklearmedizin; Danos, P. [Psychiatrische Universitaetsklinik, Bonn (Germany); Walter, H. [Universitaetsklinik fuer Psychiatrie, Wien (Austria); Klemm, E. [Bonn Univ. (Germany). Klinik fuer Nuklearmedizin; Bruecke, T. [Universitaetsklinik fuer Neurologie, Wien (Austria); Podreka, I. [Universitaetsklinik fuer Neurologie, Wien (Austria); Biersack, H.J. [Bonn Univ. (Germany). Klinik fuer Nuklearmedizin

    1994-10-01

    In the last fifteen years different attempts have been undertaken to understand the biological basis of major psychiatric disorders. One important tool to determine patterns of brain dysfunction is single emission computed tomography (SPECT). Whereas SPECT investigations are already a valuable diagnostic instrument for the diagnosis of dementia of the Alzheimer Type (DAT) there have not been consistent findings that can be referred to as specific for any other particular psychiatric diagnostic entity. Nevertheless, SPECT studies have been able to demonstrate evidence of brain dysfunction in patients with schizophrenia, depression, anxiety disorders, and substance abuse in which other methods showed no clear abnormality of brain function. Our manuscript reviews the data which are currently available in the literature and stresses the need for further studies, especially for prediction and monitoring psychiatric treatment modalities. (orig.) [Deutsch] In den vergangenen 15 Jahren wurde durch verschiedene methodologische Ansaetze versucht, die biologischen Ursachen psychiatrischer Erkrankungen naeher zu erforschen. Als eine bedeutende Methode hat sich dabei die Single-Photonen-Emissions-Computertomographie (SPECT) herausgestellt. Waehrend die SPECT-Untersuchungen bereits Eingang in die Routinediagnostik bei Demenzen vom Alzheimer-Typ gefunden haben, konnten fuer weitere psychiatrische Erkrankungen noch keine eindeutigen Befunde etabliert werden. Mit der SPECT-Methode ist es jedoch gelungen, funktionelle Veraenderungen des Gehirns von psychiatrischen Erkrankungen darzustellen, wie z.B. Schizophrenie, Depression, Angsterkrankungen bzw. Substanzmissbrauch. In Forschungsprotokollen wird durch die SPECT-Methode versucht, abzuklaeren, inwieweit es moeglich ist, innerhalb der Erkrankungsentitaeten psychiatrischer Erkrankungen oder auch diese uebergreifend eine Subklassifizierung zu finden und evtl. Gehirnsysteme ausfindig zu machen, die mit einer spezifischen

  19. Estudio de la reserva de perfusión miocárdica mediante tomografía de emisión de fotón único con talio-201 y estrés farmacológico con adenosina trifosfato en pacientes con factores de riesgo cardiovascular

    National Research Council Canada - National Science Library

    Huelmos Rodrigo, Ana; Alegría Ezquerra, Eduardo; Martínez Caro, Diego; José García Velloso, María; Ángel Richter Echevarría, José

    1997-01-01

    ...- nificativamente más bajas en los individuos con factores de riesgo cardiovascular que en los suje- aquellos con enfermedad coronaria, lo que puede sugerir que se encuentran en una etapa precoz de aterosclerosis. STUDY OF MYOCARDIAL PERFUSION RESERVE WITH SINGLE-PHOTON-EMISSION COMPUTED TOMOGRAPHY WITH THALLIUM-201 AND PHARMACOLOGICAL STRESS W...

  20. Exercise {beta}-methyl iodophenyl pentadecanoic acid (BMIPP) and resting thallium delayed single photon emission computed tomography (SPECT) in the assessment of ischemia and viability

    Energy Technology Data Exchange (ETDEWEB)

    Mori, Takao; Hayakawa, Masanori; Hattori, Kaoru; Awano, Koujirou; Masuda, Jun; Inatome, Tetsuya; Fukuzaki, Hisashi [Miki City Hospital, Hyogo (Japan)

    1996-01-01

    To clarify the significance of exercise BMIPP and resting Tl delayed SPECT in the assessment of ischemia and viability, we studied maximal exercise-loading BMIPP SPECT following rest-injected Tl 3h SPECT in 11 control subjects, 20 with effort angina and 38 with old myocardial infarction. BMIPP and Tl uptake were scored as 0=normal, 1=reduced, 2=severely reduced, or 3=absent. Discordance was defined as when segments with a reduced BMIPP uptake had a better resting Tl uptake. Significant coronary artery stenosis was defined as stenosis of 75% or greater on coronary arteriogram. Left ventricular wall motion was assessed as either normokinesis, hypokinesis, severe hypokinesis, akinesis or dyskinesis on left ventriculogram. When discordance was considered to be a marker of ischemia, the sensitivity and specificity in effort angina and control subjects were 95.2% and 84.6% for patients and 83.9% and 94.4% for disease vessels, respectively. There were no differences between the sensitivity and specificity in left anterior descending artery (LAD), left circumflex artery (LCx) and right coronary artery (RCA) lesions (83.3%, 95.5% in LAD, 83.3%, 95.5% in LCx, 85.7%, 92.6% in RCA, respectively). All of the patients with old myocardial infarction had reduced exercise BMIPP uptake in infarcted regions. In old myocardial infarction, 35 patients had segments with discordant uptake. Discordance was observed in 75 (91.5%) of 82 segments with hypokinesis, and in 24 (92.3%) of 26 segments with severe hypokinesis. Even among the 36 segments with akinesis or dyskinesis, 25 (69.0%) had discordant uptake. When discordance in the infarcted region was considered to be a marker of viability, regions with severe asynergy showed a high possibility of viability. Thus, discordant uptake on exercise BMIPP and resting Tl delayed SPECT may be a useful marker of ischemia in effort angina and of viability in old myocardial infarction. (author).

  1. SPECT and PET in Eating Disorders

    NARCIS (Netherlands)

    van Waarde, Aren; Audenaert, Kurt; Busatto, Geraldo F.; Buchpiguel, Carlos; Dierckx, Rudi; Dierckx, Rudi AJO; Otte, Andreas; de Vries, Erik FJ; van Waarde, Aren; den Boer, Johan A

    2014-01-01

    Medical imaging techniques like PET and SPECT have been applied for investigation of brain function in anorexia and bulimia nervosa. Regional abnormalities have been detected in cerebral blood flow, glucose metabolism, the availability of several neurotransmitter receptors (serotonin 1A and 2A,

  2. Methodology for ventilation/perfusion SPECT

    DEFF Research Database (Denmark)

    Bajc, Marika; Neilly, Brian; Miniati, Massimo

    2010-01-01

    Ventilation/perfusion single-photon emission computed tomography (V/Q SPECT) is the scintigraphic technique of choice for the diagnosis of pulmonary embolism and many other disorders that affect lung function. Data from recent ventilation studies show that the theoretic advantages of Technegas ov...

  3. PET and SPECT of neurobiological systems

    Energy Technology Data Exchange (ETDEWEB)

    Dierckx, Rudi A.J.O. [Groningen Univ. (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging; Gent Univ. (Belgium). Dept. of Nuclear Medicine; Otte, Andreas [Univ. of Applied Sciences, Offenburg (Germany). Faculty of Electrical Engineering and Information Technology; Vries, Erik F.J. de; Waarde, Aren van (eds.) [Groningen Univ. (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging

    2014-04-01

    Addresses a variety of aspects of neurotransmission in the brain. Details the latest results in probe development. Emphasis on a multidisciplinary approach. Written by internationally acclaimed experts. PET and SPECT of Neurobiological Systems combines the expertise of renowned authors whose dedication to the development of novel probes and techniques for the investigation of neurobiological systems has achieved international recognition. Various aspects of neurotransmission in the brain are discussed, such as visualization and quantification of (more than 20 different) neuroreceptors, neuroinflammatory markers, transporters, and enzymes as well as neurotransmitter synthesis, ?-amyloid deposition, cerebral blood flow, and the metabolic rate of glucose. The latest results in probe development are also detailed. Most chapters are written jointly by radiochemists and nuclear medicine specialists to ensure a multidisciplinary approach. This state of the art compendium will be valuable to anyone in the field of clinical or preclinical neuroscience, from the radiochemist and radiologist/nuclear medicine specialist to the interested neurobiologist and general practitioner. It is the second volume of a trilogy on PET and SPECT imaging in the neurosciences. Other volumes focus on PET and SPECT in psychiatry and PET and SPECT in neurology''.

  4. Chilaiditi's syndrome demonstrated by SPECT/CT

    Directory of Open Access Journals (Sweden)

    Nalini S Perumal

    2009-11-01

    Full Text Available Purpose: Chilaiditi’s syndrome is a rare condition commonly diagnosed as an incidental radiological finding. The aim of this report is to show the role of SPECT-CT in this syndrome and state the functional and anatomical role of this hybrid imaging modality. Materials and Methods: A case report. Results: A 49-year-old female patient was referred for gallium-67 citrate for a possible granulomatous myositis and underwent SPECT-CT of the abdomen to assess the area of decreased gallium uptake on planar images of the liver. The combined SPECT and CT modality demonstrated findings consistent with the clinical evidence of Chilaiditi’s syndrome. The anatomical part of this hybrid modality made it easier to evaluate the area of gallium lack of uptake which was due to air in the colon. Conclusion: This case does not only show the role of SPECT-CT in this syndrome but also suggest that the use of such modality should be considered whenever available in the evaluation of patients in whom the localization of active disease becomes imperative.

  5. SPECT/CT and pulmonary embolism

    DEFF Research Database (Denmark)

    Mortensen, Jann; Borgwardt, Henrik Gutte

    2014-01-01

    Acute pulmonary embolism (PE) is diagnosed either by ventilation/perfusion (V/P) scintigraphy or pulmonary CT angiography (CTPA). In recent years both techniques have improved. Many nuclear medicine centres have adopted the single photon emission CT (SPECT) technique as opposed to the planar...

  6. Noninvasive quantification of coronary endothelial function by SPECT imaging in children with a history of Kawasaki disease

    Energy Technology Data Exchange (ETDEWEB)

    Cicala, Silvana; Paladini, Rodolfo; Leva, Francesco de [Santobono-Pausilipon Children Medical Hospital, Division of Cardiology, Department of Paediatrics, Naples (Italy); Pellegrino, Teresa; Caprio, Maria Grazia [Institute of Diagnostic and Nuclear Development, SDN Foundation, Naples (Italy); Storto, Giovanni [IRCCS, CROB, Rionero in Vulture (Italy); Mainolfi, Ciro; Cuocolo, Alberto [Federico II University, Department of Biomorphological and Functional Sciences, Naples (Italy); National Council of Research, Institute of Biostructures and Bioimages, Naples (Italy)

    2010-12-15

    The feasibility of coronary function estimation by single photon emission computed tomography (SPECT) has been recently demonstrated. The aim of this study was to apply SPECT imaging in patients with previous Kawasaki disease (KD) to assess the coronary functional status at long-term follow-up of the acute phase of the disease. Sixteen children with a history of KD underwent {sup 99m}Tc-sestamibi imaging at rest and during the cold pressor test (CPT). Myocardial blood flow (MBF) was estimated by measuring first transit counts in the pulmonary artery and myocardial counts from SPECT images. Coronary endothelial function was expressed as the ratio of the CPT to rest MBF. Six KD patients without coronary artery lesions served as controls and ten with coronary artery aneurysms during the acute phase of the disease were separated into two groups: group 1 (n = 4) with regressed and group 2 (n = 6) with persistent aneurysm at follow-up. The estimated coronary endothelial function was higher in controls compared to patients with coronary artery aneurysms (2.5 {+-} 0.3 vs 1.7 {+-} 0.7, p < 0.05). A significant difference in coronary endothelial function among groups was found (F = 5.21, p < 0.02). Coronary endothelial function was higher in patients of group 1 than in those of group 2 (1.9 {+-} 0.6 vs 1.4 {+-} 0.7, p < 0.02). SPECT may be applied as a noninvasive method for assessing coronary vascular function in children with a history of KD, demonstrating an impaired response to the CPT, an endothelial-dependent vasodilator stimulus. These findings reinforce the concept that coronary endothelial dysfunction may represent a long-term sequela of KD. (orig.)

  7. Addition of atropine to submaximal exercise stress testing in patients evaluated for suspected ischaemia with SPECT imaging: a randomized, placebo-controlled trial

    Energy Technology Data Exchange (ETDEWEB)

    Manganelli, Fiore; Sauro, Rosario; Di Lorenzo, Emilio; Rosato, Giuseppe [San Giuseppe Moscati Hospital, Department of Cardiology and Heart Surgery, Avellino (Italy); Spadafora, Marco; Varrella, Paola; Peluso, Giuseppina [San Giuseppe Moscati Hospital, Nuclear Medicine Unit, Avellino (Italy); Daniele, Stefania [Institute of Diagnostic and Nuclear Development (SDN), Naples (Italy); Cuocolo, Alberto [Institute of Diagnostic and Nuclear Development (SDN), Naples (Italy); University Federico II, Department of Biomorphological and Functional Sciences, Naples (Italy); National Council of Research, Institute of Biostructures and Bioimages, Naples (Italy)

    2011-02-15

    To evaluate the effects of the addition of atropine to exercise testing in patients who failed to achieve their target heart rate (HR) during stress myocardial perfusion imaging with single-photon emission computed tomography (SPECT). The study was a prospective, randomized, placebo-controlled design. Patients with suspected or known coronary artery disease who failed to achieve a target HR ({>=}85% of maximal predicted HR) during exercise SPECT imaging were randomized to receive intravenous atropine (n = 100) or placebo (n = 101). The two groups of patients did not differ with respect to demographic or clinical characteristics. A higher proportion of patients in the atropine group achieved the target HR compared to the placebo group (60% versus 3%, p < 0.0001). SPECT imaging was abnormal in a higher proportion of patients in the atropine group as compared to the placebo group (57% versus 42%, p < 0.05). Stress-induced myocardial ischaemia was present in more patients in the atropine group as compared to placebo (47% versus 29%, p < 0.01). In both groups of patients, no major side effects occurred. The addition of atropine at the end of exercise testing is more effective than placebo in raising HR to adequate levels, without additional risks of complications. The use of atropine in patients who initially failed to achieve their maximal predicted HR is associated with a higher probability of achieving a diagnostic myocardial perfusion study. (orig.)

  8. Integrated SPECT/CT for assessment of haemodynamically significant coronary artery lesions in patients with acute coronary syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Rispler, Shmuel [Technion - Israel Institute of Technology, Department of Cardiology, Rambam Health Care Campus and the B. Rappaport Faculty of Medicine, Haifa (Israel); Technion - Israel Institute of Technology, Department of Nuclear Medicine, Rambam Health Care Campus and the B. Rappaport Faculty of Medicine, Haifa (Israel); Aronson, Doron; Roguin, Ariel; Beyar, Rafael [Technion - Israel Institute of Technology, Department of Cardiology, Rambam Health Care Campus and the B. Rappaport Faculty of Medicine, Haifa (Israel); Abadi, Sobhi; Engel, Ahuva [Technion - Israel Institute of Technology, Department of Medical Imaging, Rambam Health Care Campus and the B. Rappaport Faculty of Medicine, Haifa (Israel); Israel, Ora; Keidar, Zohar [Technion - Israel Institute of Technology, Department of Nuclear Medicine, Rambam Health Care Campus and the B. Rappaport Faculty of Medicine, Haifa (Israel)

    2011-10-15

    Early risk stratification in patients with non-ST elevation acute coronary syndromes (NSTE-ACS) is important since the benefit from more aggressive and costly treatment strategies is proportional to the risk of adverse clinical events. In the present study we assessed whether hybrid single photon emission computed tomography (SPECT)/coronary computed tomography angiography (CCTA) technology could be an appropriate tool in stratifying patients with NSTE-ACS. SPECT/CCTA was performed in 90 consecutive patients with NSTE-ACS. The Thrombolysis in Myocardial Infarction risk score (TIMI-RS) was used to classify patients as low- or high-risk. Imaging was performed using SPECT/CCTA to identify haemodynamically significant lesions defined as >50% stenosis on CCTA with a reversible perfusion defect on SPECT in the corresponding territory. CCTA demonstrated at least one lesion with >50% stenosis in 35 of 40 high-risk patients (87%) as compared to 14 of 50 low-risk patients (35%; TIMI-RS <3; p <0.0001). Of the 40 high-risk and 50 (16%) low-risk TIMI-RS patients, 16 (40%) and 8 (16%), respectively, had haemodynamically significant lesions (p = 0.01). Patients defined as high-risk by a high TIMI-RS, a positive CCTA scan or both (n = 45) resulted in a sensitivity of 95%, specificity of 49%, PPV of 35% and NPV of 97% for having haemodynamically significant coronary lesions. Those with normal perfusion were spared revascularization procedures, regardless of their TIMI-RS. Noninvasive assessment of coronary artery disease by SPECT/CCTA may play an important role in risk stratification of patients with NSTE-ACS by better identifying the subgroup requiring intervention. (orig.)

  9. Cintilografia do miocárdio com tecnécio 99m-MIBI e administração de adenosina em portadores de doença arterial coronária: correlação dos resultados com a angiografia coronária e o ultra-som intracoronário Adenosine myocardial perfusion SPECT with Tc-99m-MIBI in patients with obstructive coronary artery disease: correlation between quantitative coronary angiography and intravascular ultrasound measurements

    Directory of Open Access Journals (Sweden)

    Luiz Eduardo Mastrocolla

    2006-01-01

    (MLA determined by QCA and IVUS. CONCLUSION: Tc-99m-MIBI and adenosine myocardial SPECT is correlated with % CSA on IVUS, perfusion images considered. Global results assessment showed association between lumen diameter and area at obstructed sites as determined by QCA and IVUS.

  10. Exercise may cause myocardial ischemia at the anaerobic threshold in cardiac rehabilitation programs.

    Science.gov (United States)

    Fuchs, A R C N; Meneghelo, R S; Stefanini, E; De Paola, A V; Smanio, P E P; Mastrocolla, L E; Ferraz, A S; Buglia, S; Piegas, L S; Carvalho, A A C

    2009-03-01

    Myocardial ischemia may occur during an exercise session in cardiac rehabilitation programs. However, it has not been established whether it is elicited when exercise prescription is based on heart rate corresponding to the anaerobic threshold as measured by cardiopulmonary exercise testing. Our objective was to determine the incidence of myocardial ischemia in cardiac rehabilitation programs according to myocardial perfusion SPECT in exercise programs based on the anaerobic threshold. Thirty-nine patients (35 men and 4 women) diagnosed with coronary artery disease by coronary angiography and stress technetium-99m-sestamibi gated SPECT associated with a baseline cardiopulmonary exercise test were assessed. Ages ranged from 45 to 75 years. A second cardiopulmonary exercise test determined training intensity at the anaerobic threshold. Repeat gated-SPECT was obtained after a third cardiopulmonary exercise test at the prescribed workload and heart rate. Myocardial perfusion images were analyzed using a score system of 6.4 at rest, 13.9 at peak stress, and 10.7 during the prescribed exercise (P exercise was defined as a difference > or = 2 between the summed stress score and summed rest score. Accordingly, 25 (64%) patients were classified as ischemic and 14 (36%) as nonischemic. MIBI-SPECT showed myocardial ischemia during exercise within the anaerobic threshold. The 64% prevalence of ischemia observed in the study should not be looked on as representative of the whole population of patients undergoing exercise programs. Changes in patient care and exercise programs were implemented as a result of our finding of ischemia during the prescribed exercise.

  11. SPECT/CT imaging in children with papillary thyroid carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hwa-Young; Gelfand, Michael J.; Sharp, Susan E. [Cincinnati Children' s Hospital, Department of Radiology, Cincinnati, OH (United States)

    2011-08-15

    SPECT/CT improves localization of single photon-emitting radiopharmaceuticals. To determine the utility of SPECT/CT in children with papillary thyroid carcinoma. 20 SPECT/CT and planar studies were reviewed in 13 children with papillary thyroid carcinoma after total thyroidectomy. Seven studies used I-123 and 13 used I-131, after elevating TSH by T4 deprivation or intramuscular thyrotropin alfa. Eight children had one study and five children had two to four studies. Studies were performed at initial post-total thyroidectomy evaluation, follow-up and after I-131 treatment doses. SPECT/CT was performed with a diagnostic-quality CT unit in 13 studies and a localization-only CT unit in 7. Stimulated thyroglobulin was measured (except in 2 cases with anti-thyroglobulin antibodies). In 13 studies, neck activity was present but poorly localized on planar imaging; all foci of uptake were precisely localized by SPECT/CT. Two additional foci of neck uptake were found on SPECT/CT. SPECT/CT differentiated high neck uptake from facial activity. In six studies (four children), neck uptake was identified as benign by SPECT/CT (three thyroglossal duct remnants, one skin contamination, two by precise anatomical CT localization). In two children, SPECT/CT supported a decision not to treat with I-131. When SPECT/CT was unable to identify focal uptake as benign, stimulated thyroglobulin measurements were valuable. In three of 13 studies with neck uptake, SPECT/CT provided no useful additional information. SPECT/CT precisely localizes neck iodine uptake. In small numbers of patients, treatment is affected. SPECT/CT should be used when available in thyroid carcinoma patients. (orig.)

  12. Diagnostic advantage of stress computed tomography myocardial perfusion over single-photon emission computed tomography for the assessment of myocardial ischemia.

    Science.gov (United States)

    Ueki, Yasushi; Izawa, Atsushi; Kashiwagi, Daisuke; Nishiyama, Shigeki; Aso, Shinichi; Suzuki, Chihiro; Sakurai, Shumpei; Oguchi, Kazuhiro; Yazaki, Yoshikazu; Ikeda, Uichi; Kuwahara, Koichiro

    2017-08-01

    This study compared adenosine stress computed tomography myocardial perfusion (CTP) with single-photon emission computed tomography (SPECT) in the diagnosis of functionally significant coronary artery stenosis using fractional flow reserve (FFR) as reference standard. We included a total of 93 coronary arteries from 31 patients in whom at least one vessel with ≥50% stenosis was detected with computed tomography coronary angiography. All patients underwent both SPECT and adenosine stress CTP, followed by invasive coronary angiography (ICA) and FFR. Diagnostic accuracy between CTP and SPECT was compared according to positive findings of either ≥99% stenosis on ICA or FFR ≤0.8. Among 78 vessels eligible for the quantitative analyses, significant coronary artery disease (CAD) was diagnosed in 22 vessels of 19 patients. Comparison of CTP vs. SPECT for sensitivity, specificity, positive predictive value (PPV), negative predictive value, and accuracy in detecting significant CAD were 59% vs. 18%, 96% vs. 93%, 87% vs. 50%, 86% vs. 74%, and 86% vs. 72%, respectively. CTP demonstrated a significant diagnostic advantage over SPECT in the identification of significant CAD, especially in terms of sensitivity and PPV. Adenosine stress CTP is useful for the noninvasive diagnosis of functionally significant CAD. Copyright © 2016 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  13. Comparison of thallium deposition with segmental perfusion in pigs with chronic hibernating myocardium.

    Science.gov (United States)

    Baldwa, Sunil; Rana, Muzamil; Canty, John M; Fallavollita, James A

    2008-12-01

    Viable, chronically dysfunctional myocardium with reduced resting flow (or hibernating myocardium) is an important prognostic factor in ischemic heart disease. Although thallium-201 imaging is frequently used to assess myocardial viability in patients with ischemic cardiomyopathy, there are limited data regarding its deposition in hibernating myocardium, and this data suggest that thallium retention may be supernormal compared with control myocardium. Accordingly, pigs (n=7) were chronically instrumented with a 1.5 mm Delrin stenosis on the proximal left anterior descending coronary artery (LAD) to produce hibernating myocardium. Four months later, severe anteroapical hypokinesis was documented with contrast ventriculography (wall motion score, 0.7+/-0.8; normal=3), and microsphere measurements confirmed reduced resting flow (LAD subendocardium, 0.78+/-0.34 vs. 0.96+/-0.24 ml.min(-1).g(-1) in remote; P<0.001). Absolute deposition of thallium-201 and insulin-stimulated [18F]-2 fluoro-2-deoxyglucose (FDG) were assessed over 1 h and compared with resting flow (n=704 samples). Thallium-201 deposition was only weakly correlated with perfusion (r2=0.20; P<0.001) and was more homogeneously distributed (relative dispersion, 0.12+/-0.03 vs. 0.29+/-0.10 for microsphere flow; P<0.01). Thus after 1 h relative thallium-201 (subendocardium LAD/remote, 0.96+/-0.16) overestimated relative perfusion (0.78+/-0.32; P<0.0001) and underestimated the relative reduction in flow. Viability was confirmed by both histology and preserved FDG uptake. We conclude that under resting conditions, thallium-201 redistribution in hibernating myocardium is nearly complete within 1 h, with similar deposition to remote myocardium despite regional differences in flow. These data suggest that in this time frame thallium-201 deposition may not discriminate hibernating myocardium from dysfunction myocardium with normal resting flow. Since hibernating myocardium has been associated with a worse prognosis

  14. Validation of Contrast Enhanced Cine Steady-State Free Precession and T2-Weigthed CMR for Assessment of Ischemic Myocardial Area- At-Risk

    DEFF Research Database (Denmark)

    Søvsø Szocska Hansen, Esben; Pedersen, Steen Fjord; Pedersen, Steen Bønløkke

    2017-01-01

    Measuring myocardial salvage is important to evaluate the possible cardioprotective effects of adjunctive cardioprotective intervention in patients with myocardial infarction undergoing primary percutaneous intervention. Contrast-enhanced steady-state free precession magnetic resonance imaging (CE-CINE......) has recently been used to quantify AAR and validated against myocardial perfusion SPECT. In this study we sought to determine how well T2-STIR and CE-CINE depicts AAR in an experimental porcine model of myocardial ischemia-reperfusion injury using histopathology as the reference for infarct size...

  15. Myocardial contrast echocardiography in mice: Technical and physiological aspects.

    Science.gov (United States)

    Verkaik, Melissa; van Poelgeest, Erik; Kwekkeboom, Rick F J; Ter Wee, Piet M; van den Brom, Charissa E; Vervloet, Marc G; Eringa, Etto C

    2017-11-03

    Myocardial contrast echocardiography (MCE) offers the opportunity to study myocardial perfusion defects in mice in detail. The value of MCE compared to SPECT, PET and CT consists of high spatial resolution, the possibility of quantification of blood volume and relatively low costs. Nevertheless, a number of technical and physiological aspects should be considered to ensure reproducibility among research groups. The aim of this overview is to describe technical aspects of MCE and the physiological parameters that influence myocardial perfusion data obtained with this technique. First, technical aspects of MCE discussed in this technical review are logarithmic compression of ultrasound data by ultrasound systems, saturation of the contrast signal and acquisition of images during different phases of the cardiac cycle. Second, physiological aspects of myocardial perfusion that are affected by the experimental design are discussed, including the anesthesia regimen, systemic cardiovascular effects of vasoactive agents used and fluctuations in body temperature that alter myocardial perfusion. When these technical and physiological aspects of MCE are taken into account and adequately standardized, MCE is an easily accessible technique for mice that can be used to study the control of myocardial perfusion by a wide range of factors. Copyright © 2017, American Journal of Physiology-Heart and Circulatory Physiology.

  16. System calibration and image reconstruction for a new small-animal SPECT system

    Science.gov (United States)

    Chen, Yi-Chun

    as the Gauss-Seidel (GS) iteration and the algebraic reconstruction technique (ART). These algorithms were compared in terms of their computational cost, data-agreement measures and subjective assessment of image quality. The spatial resolution of the imaging system was visualized through a miniature Derenzo hot-rod phantom. The smallest rods with 1-mm diameters and 3-mm center-to-center distance were clearly resolved. Mouse bone, kidney and cardiac images illustrated the ability of FastSPECT II to provide high-quality small-animal images. The dynamic-imaging capability was demonstrated via rat myocardial studies. FastSPECT II can be modified to achieve higher angular sampling and higher magnification. Fourier crosstalk analysis and synthetic phantom studies showed that higher angular sampling improved the spatial resolution and image quality along two transverse axes. Line-phantom and mouse-femur images demonstrated the sub-millimeter resolution of FastSPECT II in the high-magnification (18X) configuration.

  17. High diagnostic accuracy of low-dose gated-SPECT with solid-state ultrafast detectors: preliminary clinical results

    Energy Technology Data Exchange (ETDEWEB)

    Gimelli, Alessia; Genovesi, Dario; Giorgetti, Assuero; Marzullo, Paolo [CNR, Fondazione Toscana Gabriele Monasterio, Pisa (Italy); Bottai, Matteo [University of South Carolina, Division of Biostatistics, Columbia, SC (United States); Karolinska Institutet, Division of Biostatistics, Stockholm (Sweden); Di Martino, Fabio [AOUP, UO Fisica Sanitaria, Pisa (Italy)

    2012-01-15

    Appropriate use of SPECT imaging is regulated by evidence-based guidelines and appropriateness criteria in an effort to limit the burden of radiation administered to patients. We aimed at establishing whether the use of a low dose for stress-rest single-day nuclear myocardial perfusion imaging on an ultrafast (UF) cardiac gamma camera using cadmium-zinc-telluride solid-state detectors could be used routinely with the same accuracy obtained with standard doses and conventional cameras. To this purpose, 137 consecutive patients (mean age 61 {+-} 8 years) with known or suspected coronary artery disease (CAD) were enrolled. They underwent single-day low-dose stress-rest myocardial perfusion imaging using UF SPECT and invasive coronary angiography. Patients underwent the first scan with a 7-min acquisition time 10 min after the end of the stress protocol (dose range 185 to 222 MBq of {sup 99m}Tc-tetrofosmin). The rest scan (dose range 370 to 444 MBq of {sup 99m}Tc-tetrofosmin) was acquired with a 6-min acquisition time. The mean summed stress scores (SSS) and mean summed rest scores (SRS) were obtained semiquantitatively. Coronary angiograms showed significant epicardial CAD in 83% of patients. Mean SSS and SRS were 10 {+-} 5 and 3 {+-} 3, respectively. Overall the area under the ROC curve for the SSS values was 0.904, while the areas under the ROC curves for each vascular territory were 0.982 for the left anterior descending artery, 0.931 for the left circumflex artery and 0.889 for the right coronary artery. This pilot study demonstrated the feasibility of a low-dose single-day stress-rest fasting protocol performed using UF SPECT, with good sensitivity and specificity in detecting CAD at low patient exposure, opening new perspectives in the use of myocardial perfusion in ischaemic patients. (orig.)

  18. The characteristics of syndrome X based on {sup 201}Tl-SPECT, {sup 18} FDG-PET and histopathologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Satake, Osamichi [Kanazawa Medical Univ. (Japan)

    1999-03-01

    Syndrome X is a microvascular disease. However, the relationship between microvascular ischemia and histopathological findings remains unknown. The present study was performed to evaluate the myocardial perfusion and metabolism of patients with Syndrome X using {sup 201}Tl-SPECT and {sup 18}FDG-PET, and to clarify the morphological characteristics with a ventricular myocardial biopsy. We examined 24 patients with Syndrome X and 5 patients with myocarditis as a control group. In the study using {sup 201}Tl-SPECT and {sup 18}FDG-PET, we evaluated the presence or absence of myocardial ischemia. We calculated the Standardized Uptake Value (SUV) (%dose/ml) of {sup 18}FDG, and analyzed quantitatively the degree of ischemia. For histopathologic study on coronary microcirculation, we performed a right ventricular myocardial biopsy. The biopsies were examined light and electron microscopically. The semithin sections, stained with toluidine blue, were projected onto a screen. Microvessels were counted and the ratio of microvascular luminal narrowing and the number of microvessels per unit area were determined. The study using {sup 201}Tl-SPECT and {sup 18}FDG-PET showed that hypoperfusion of {sup 201}Tl was found in 17 of 24 (71%) patients during {sup 201}Tl-loaded myocardial scanning together with redistribution of {sup 201}Tl at the same regions; {sup 18}FDG-uptake were found in all 24 patients during {sup 18}FDG-PET performed under resting and fasting conditions; the SUV of {sup 18}FDG in the Syndrome X group (0.025{+-}0.039 %dose/ml) was significantly different from that of the control group (0.003{+-}0.002 %dose/ml) (p<0.01). Histopathological observations under the both light and electron microscope showed that an increment in number of the endothelial cells with swelling, a marked luminal narrowing due to the hypertrophy of the arteriolar media and the capillary walls, and a compression of the capillaries were shown in all the patients; the ratio of luminal narrowing

  19. Myocardial perfusion abnormality and effects of Ca channel blockers on myocardial ischemia in patients with hypertrophic cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Taniguchi, Yoko [Kyoto Prefectural Univ. of Medicine (Japan)

    1997-03-01

    The purpose of this study was to investigate the frequency of myocardial ischemia and characteristic regions of myocardial hypoperfusion during stress in patients with hypertrophic cardiomyopathy. Furthermore, the effects of Ca channel blocker (verapamil, diltiazem) on myocardial ischemia were studied. One hundred patients with hypertrophic cardiomyopathy underwent exercise {sup 201}Tl SPECT. Sixty-eight patients had one or more {sup 201}Tl abnormalities. Of the 68 patients with {sup 201}Tl abnormalities, 56 had reversible {sup 201}Tl abnormalities and 12 had fixed defect. {sup 201}Tl abnormalities were frequently distributed in the anterior and posterior areas of junction between the ventricular septum and the free wall and the apex. Of the 56 patients with reversible {sup 201}Tl abnormalities, 40 patients underwent one more exercise {sup 201}Tl SPECT after 8 weeks of oral administration of verapamil or diltiazem. The {sup 201}Tl defect was visually scored as the defect score. Transient dilation index was calculated as an index of subendocardial ischemia. The mean defect score decreased significantly from 9.80{+-}4.35 to 5.50{+-}4.63 after verapamil and from 9.90{+-}5.17 to 5.50{+-}4.89 after diltiazem. Mean transient dilation index decreased from 1.20{+-}0.12 to 1.08{+-}0.09 after treatment with verapamil and from 1.16{+-}0.10 to 1.02{+-}0.09 after treatment with diltiazem. (K.H.)

  20. Functional neuroimaging in epilepsy: FDG-PET and SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang Kun; Lee, Dong Soo [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2003-02-01

    Finding epileptogenic zone is the most important step for the successful epilepsy surgery. F-18 fluorodeoxyglucose positron emission tomography (FDG-PET) and single photon emission computed tomography (SPECT) can be used in the localization of epileptogenic foci. In medial temporal lobe epilepsy, the diagnostic sensitivity of FDG-PET and ictal SPECT is excellent. However, detection of hippocampal sclerosis by MRI is so certain that use of FDG-PET and ictal SPECT in medial temporal lobe epilepsy is limited for some occasions. In neocortical epilepsy, the sensitivities of FDG-PET or ictal SPECT are fair. However, FDG-PET and ictal SPECT can have a crucial role in the localization of epileptogenic foci for non-lesional neocortical epilepsy. Interpretation of FDG-PET has been recently advanced by voxel-based analysis and automatic volume of interest analysis based on a population template. Both analytical methods can aid the objective diagnosis of epileptogenic foci. lctal SPECT was analyzed using subtraction methods and voxel-based analysis. Rapidity of injection of tracers, ictal EEG findings during injection of tracer, and repeated ictal SPECT were important technical issues of ictal SPECT. SPECT can also be used in the evaluation of validity of Wada test.

  1. Diagnostic accuracy of combined coronary angiography and adenosine stress myocardial perfusion imaging using 320-detector computed tomography: pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Nasis, Arthur; Ko, Brian S.; Leung, Michael C.; Antonis, Paul R.; Wong, Dennis T.; Kyi, Leo; Cameron, James D.; Meredith, Ian T.; Seneviratne, Sujith K. [Southern Health and Monash University, Monash Cardiovascular Research Centre, Monash Heart, Department of Medicine Monash Medical Centre (MMC), Melbourne (Australia); Nandurkar, Dee; Troupis, John M. [MMC, Southern Health, Department of Diagnostic Imaging, Melbourne (Australia)

    2013-07-15

    To determine the diagnostic accuracy of combined 320-detector row computed tomography coronary angiography (CTA) and adenosine stress CT myocardial perfusion imaging (CTP) in detecting perfusion abnormalities caused by obstructive coronary artery disease (CAD). Twenty patients with suspected CAD who underwent initial investigation with single-photon-emission computed tomography myocardial perfusion imaging (SPECT-MPI) were recruited and underwent prospectively-gated 320-detector CTA/CTP and invasive angiography. Two blinded cardiologists evaluated invasive angiography images quantitatively (QCA). A blinded nuclear physician analysed SPECT-MPI images for fixed and reversible perfusion defects. Two blinded cardiologists assessed CTA/CTP studies qualitatively. Vessels/territories with both >50 % stenosis on QCA and corresponding perfusion defect on SPECT-MPI were defined as ischaemic and formed the reference standard. All patients completed the CTA/CTP protocol with diagnostic image quality. Of 60 vessels/territories, 17 (28 %) were ischaemic according to QCA/SPECT-MPI criteria. Sensitivity, specificity, PPV, NPV and area under the ROC curve for CTA/CTP was 94 %, 98 %, 94 %, 98 % and 0.96 (P < 0.001) on a per-vessel/territory basis. Mean CTA/CTP radiation dose was 9.2 {+-} 7.4 mSv compared with 13.2 {+-} 2.2 mSv for SPECT-MPI (P < 0.001). Combined 320-detector CTA/CTP is accurate in identifying obstructive CAD causing perfusion abnormalities compared with combined QCA/SPECT-MPI, achieved with lower radiation dose than SPECT-MPI. (orig.)

  2. Methodology for ventilation/perfusion SPECT

    DEFF Research Database (Denmark)

    Bajc, Marika; Neilly, Brian; Miniati, Massimo

    2010-01-01

    Ventilation/perfusion single-photon emission computed tomography (V/Q SPECT) is the scintigraphic technique of choice for the diagnosis of pulmonary embolism and many other disorders that affect lung function. Data from recent ventilation studies show that the theoretic advantages of Technegas over...... radiolabeled liquid aerosols are not restricted to the presence of obstructive lung disease. Radiolabeled macroaggregated human albumin is the imaging agent of choice for perfusion scintigraphy. An optimal combination of nuclide activities and acquisition times for ventilation and perfusion, collimators......, and imaging matrix yields an adequate V/Q SPECT study in approximately 20 minutes of imaging time. The recommended protocol based on the patient remaining in an unchanged position during the initial ventilation study and the perfusion study allows presentation of matching ventilation and perfusion slices...

  3. SPECT/CT in pediatric patient management

    Energy Technology Data Exchange (ETDEWEB)

    Nadel, Helen R. [British Columbia Children' s Hospital, University of British Columbia, Pediatric Radiologist and Nuclear Medicine Physician, Division of Nuclear Medicine Department of Radiology, Vancouver, British Columbia (Canada)

    2014-05-15

    Hybrid SPECT/CT imaging is becoming the standard of care in pediatric imaging. Indications are mainly for oncologic imaging including mIBG scintigraphy for neuroblastoma and I-123 post surgical imaging of children with thyroid carcinoma, bone scintigraphy for back pain, children referred from sports medicine and neurodevelopmentally delayed children presenting with pain symptoms. The studies provide improved diagnostic accuracy, and oncologic imaging that includes optimized CT as part of the SPECT/CT study may decrease the number of studies and sedation procedures an individual child may need. The studies, however, must be tailored on an individual basis as the addition of the CT study can increase exposure to the child and should only be performed after appropriate justification and with adherence to optimized low dose pediatric protocols. (orig.)

  4. SPECT Molecular Imaging in Parkinson's Disease

    Directory of Open Access Journals (Sweden)

    Ling Wang

    2012-01-01

    Full Text Available Parkinson's disease (PD is a common disorder, and the diagnosis of Parkinson's disease is clinical and relies on the presence of characteristic motor symptoms. The accuracy of the clinical diagnosis of PD is still limited. Functional neuroimaging using SPECT technique is helpful in patients with first signs of parkinsonism. The changes detected may reflect the disease process itself and/or compensatory responses to the disease, or they may arise in association with disease- and/or treatment-related complications. This paper addresses the value of SPECT in early differential diagnosis of PD and its potential as a sensitive tool to assess the pathophysiology and progression, as well as the therapeutic efficacy of PD.

  5. Fuzzy segmentation approach for quantitative SPECT

    Science.gov (United States)

    Schmitt, Thomas; Freyer, Richard; Oehme, Liane; Andreeff, Michael; Franke, Wolf-Gunter

    1998-06-01

    The determination of objective numerical criteria from nuclear medicine image data renders it possible to plan and control therapies, to compare inter- and intra-individual studies as well as time course studies and to facilitate the dominating visual interpretation of scintigrams. SPECT performs real 3D functional imaging of radionuclide distributions. The basic numerical value is the functional volume of a certain region. The volume is one prerequisite for activity measurement, but the value itself is of diagnostic importance, too. For determining the region boundaries several segmentation approaches are commonly used which are generally based on interactive ROI drawing, thresholding or edge detection methods. The image quality properties of SPECT render the segmentation process more difficult in any case. We propose an alternative segmentation approach where the crisp decision `object: yes or not' is substituted by a fuzzy boundary model `object: more or less'.

  6. {sup 99m}Tc-MIBI pinhole SPECT in primary hyperparathyroidism: comparison with conventional SPECT, planar scintigraphy and ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Carlier, Thomas; Bodet-Milin, Caroline; Kraeber-Bodere, Francoise; Ansquer, Catherine [Hotel Dieu University Hospital, Nuclear Medicine Department, Nantes (France); INSERM CRCNA, Nantes (France); Oudoux, Aurore [Hotel Dieu University Hospital, Nuclear Medicine Department, Nantes (France); Mirallie, Eric [Hotel Dieu University Hospital, Surgery Department, Nantes (France); Seret, Alain [University of Liege, Institute of Physics, Experimental Medical Imaging, Liege (Belgium); Daumy, Isabelle [Ultrasonography Center, Nantes (France); Leux, Christophe [Saint Jacques University Hospital, PIMESP, Nantes (France)

    2008-03-15

    A pinhole collimator is routinely used to increase the resolution of scintigraphy. This prospective study was conducted to determine the interest of {sup 99m}Tc-MIBI pinhole single-photon emission computed tomography (SPECT) for the preoperative localisation of parathyroid lesions in primary hyperparathyroidism. All patients underwent a neck ultrasonography (US), {sup 99m}TcO{sub 4}{sup -} and {sup 99m}Tc-MIBI planar images and two consecutive SPECT with a parallel (C-SPECT) and a pinhole collimator (P-SPECT). P-SPECT was performed with a tilted detector equipped with a pinhole collimator and reconstructed with a dedicated OSEM algorithm. A diagnostic confidence score (CS) was assigned to each procedure considering intensity and extra-thyroidal location of suspected lesions: 0 = negative, 1 = doubtful, 2 = moderately positive, 3 = positive. The results of these preoperative localisation studies were compared with surgical, pathological and 6-month biological findings. Fifty-one patients cured after surgery were included. Surgery revealed 55 lesions (median weight 0.5 g, 11 in ectopy). Sensitivities of US, planar imaging, C-SPECT and P-SPECT were, respectively, 51, 76, 82 and 87%. Nine glands were only detected by tomography and five glands only by P-SPECT. {sup 99m}Tc-MIBI/{sup 99m}TcO{sub 4}{sup -} planar scans and P-SPECT were complementary and, when combined together, showed the highest sensitivity (93%). Compared with planar imaging and C-SPECT, P-SPECT increased CS for 42 and 53% of lesions, respectively, and contributed to markedly reduce the number of uncertain results. A combination of planar {sup 99m}Tc-MIBI/{sup 99m}TcO{sub 4}{sup -} scintigraphy and P-SPECT appears to be a highly accurate preoperative imaging procedure in primary hyperparathyroidism. (orig.)

  7. ENVISION, developing SPECT imaging for particle therapy

    CERN Multimedia

    2013-01-01

    Particle therapy is an advanced technique of cancer radiation therapy, using protons or other ions to target the cancerous mass. ENVISION aims at developing medical imaging tools to improve the dose delivery to the patient, to ensure a safer and more effective treatment. The animation illustrates the use of Single Photon Emission Computed Tomography (SPECT) for monitoring the dose during treatment. Produced by: CERN KT/Life Sciences and ENVISION Project Management: Manuela Cirilli 3D animation: Jeroen Huijben, Nymus3d

  8. PET and SPECT imaging in veterinary medicine.

    Science.gov (United States)

    LeBlanc, Amy K; Peremans, Kathelijne

    2014-01-01

    Veterinarians have gained increasing access to positron emission tomography (PET and PET/CT) imaging facilities, allowing them to use this powerful molecular imaging technique for clinical and research applications. SPECT is currently being used more in Europe than in the United States and has been shown to be useful in veterinary oncology and in the evaluation of orthopedic diseases. SPECT brain perfusion and receptor imaging is used to investigate behavioral disorders in animals that have interesting similarities to human psychiatric disorders. This article provides an overview of the potential applications of PET and SPECT. The use of commercially available and investigational PET radiopharmaceuticals in the management of veterinary disease has been discussed. To date, most of the work in this field has utilized the commercially available PET tracer, (18)F-fluorodeoxyglucose for oncologic imaging. Normal biodistribution studies in several companion animal species (cats, dogs, and birds) have been published to assist in lesion detection and interpretation for veterinary radiologists and clinicians. Studies evaluating other (18)F-labeled tracers for research applications are underway at several institutions and companion animal models of human diseases are being increasingly recognized for their value in biomarker and therapy development. Although PET and SPECT technologies are in their infancy for clinical veterinary medicine, increasing access to and interest in these applications and other molecular imaging techniques has led to a greater knowledge and collective body of expertise for veterinarians worldwide. Initiation and fostering of physician-veterinarian collaborations are key components to the forward movement of this field. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Staging of moyamoya disease by perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kuwabara, Yasuo [Kyushu Univ., Fukuoka (Japan). Hospital; Matsushima, Toshio; Fukui, Masashi

    2001-04-01

    Staging of moyamoya disease, based on angiography and PET have already been established. The authors have established staging of moyamoya disease based on perfusion SPECT, that can be summarized as follows: Stage I, no abnormality is seen at rest or after acetazolamide loading; Stage II, no abnormality is seen at rest, however, a decreased response (blood flow increase rate: <15%) is seen to acetazolamide loading (a, a decreased response is seen only in the frontal lobe; b, a decreased response is seen in regions other than the frontal lobe; and c, a decreased response is seen throughout the cerebrum); Stage III, localized decrease in blood flow (blood flow decrease compared with peripheral tissue: {>=}15%) and marked decrease in response to acetazolamide (blood flow increase rate: <5%) are seen at rest. In Stage III, CT and MRI show no abnormal findings or only mild lesions of the white matter; and Stage IV, multiple decreases in blood flow are seen at rest, and CT and MRI reveal infarctions and severe atrophy at the same sites. The above staging does not require determination of cerebral blood flow, and thus it can be used in children, in whom cerebral blood flow determination is difficult. The authors performed 99m-Tc ECD perfusion SPECT in 25 patients with moyamoya disease for the staging, and compared staging based on angiography with staging based on perfusion SPECT. The results did not show a correlation between the 2 staging methods. A problem inherent in the staging of moyamoya disease based on perfusion SPECT is that the relationship between cerebral blood flow and cerebral radioactivity concentrations may differ depending on the drug used to determine cerebral blood flow. Thus, although the present staging system does not depend on any specific radioactive drug to determine cerebral blood flow, further investigation is necessary to identify a more appropriate drug than those in current use. (K.H.)

  10. Accelerated GPU based SPECT Monte Carlo simulations.

    Science.gov (United States)

    Garcia, Marie-Paule; Bert, Julien; Benoit, Didier; Bardiès, Manuel; Visvikis, Dimitris

    2016-06-07

    Monte Carlo (MC) modelling is widely used in the field of single photon emission computed tomography (SPECT) as it is a reliable technique to simulate very high quality scans. This technique provides very accurate modelling of the radiation transport and particle interactions in a heterogeneous medium. Various MC codes exist for nuclear medicine imaging simulations. Recently, new strategies exploiting the computing capabilities of graphical processing units (GPU) have been proposed. This work aims at evaluating the accuracy of such GPU implementation strategies in comparison to standard MC codes in the context of SPECT imaging. GATE was considered the reference MC toolkit and used to evaluate the performance of newly developed GPU Geant4-based Monte Carlo simulation (GGEMS) modules for SPECT imaging. Radioisotopes with different photon energies were used with these various CPU and GPU Geant4-based MC codes in order to assess the best strategy for each configuration. Three different isotopes were considered: (99m) Tc, (111)In and (131)I, using a low energy high resolution (LEHR) collimator, a medium energy general purpose (MEGP) collimator and a high energy general purpose (HEGP) collimator respectively. Point source, uniform source, cylindrical phantom and anthropomorphic phantom acquisitions were simulated using a model of the GE infinia II 3/8" gamma camera. Both simulation platforms yielded a sim