WorldWideScience

Sample records for thallium-201 myocardial perfusion

  1. Exercise-induced thallium-201 myocardial perfusion defects in angina pectoris without significant coronary artery stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Nakazato, Masayasu; Maruoka, Yuji; Sunagawa, Osahiko; Kinjo, Kunihiko; Tomori, Masayuki; Fukiyama, Koshiro (Ryukyu Univ., Nishihara, Okinawa (Japan). School of Medicine)

    1990-01-01

    We performed exercise thallium-201 myocardial scintigraphy in 32 patients with angina pectoris to study the incidence of perfusion defects, who had no significant organic stenosis on coronary angiography. None of them had myocardial infarction or cardiomyopathy. Thallium-201 myocardial scintigraphy and 12-lead ECG recording were performed during supine bicycle ergometer exercise. Perfusion defects in thallium-201 scintigrams in SPECT images were assessed during visual analysis by two observers. In the coronary angiograms obtained during intravenous infusion of nitroglycerin, the luminal diameter of 75% stenosis or less in the AHA classification was regarded as an insignificant organic stenosis. Myocardial perfusion defects in the thallium-201 scintigrams were detected in eight (25%) of the 32 patients. Six of these eight patients had variant angina documented during spontaneous attacks with ST elevations in standard 12-lead ECGs. Perfusion defects were demonstrated at the inferior or infero-posterior regions in six patients, one of whom had concomitant anteroseptal defect. The defects were not always accompanied by chest pain. All but one patient demonstrating inferior or inferoposterior defects showed ST depression in leads II, III and aV{sub F} on their ECGs, corresponding to inferior wall ischemia. The exception was a case with right bundle branch block. Thus, 25% of the patients with angina pectoris, who had no evidence of significant organic stenosis on their coronary angiograms, exhibited exercise-induced perfusion defects in their thallium-201 scintigrams. Coronary spasms might have caused myocardial ischemia in these patients. (author).

  2. Dipyridamole-thallium-201 tomography documenting improved myocardial perfusion with therapy in Kawasaki disease

    Energy Technology Data Exchange (ETDEWEB)

    Nienaber, C.A.; Spielmann, R.P.; Hausdorf, G.

    1988-12-01

    Thallium-201 tomographic perfusion studies after pharmacologic vasodilation were performed in seven children (aged 2 years 8 months to 8 years 7 months), 3 to 20 months after the acute stage of the disease. In all patients coronary aneurysms were seen on cross-sectional echocardiograms. The scintigrams of six children showed no significant regional reduction of myocardial thallium-201 uptake. These children had remained asymptomatic in the follow-up period after the acute inflammatory stage of Kawasaki disease. Persistent and transient thallium defects were present in one child with acute posterolateral myocardial infarction; obstruction of two coronary vessels supplying the defect zones was confirmed by contrast angiography. After 8 months of treatment a follow-up nuclear scan showed marked reduction in the size of the defect and almost complete abolishment of the ischemic reaction. Thus tomographic thallium-201 perfusion scintigraphy in conjunction with vasodilation stress is useful to assess myocardial perfusion in children with Kawasaki disease and demonstrates marked improvement in regional perfusion after adequate medical therapy.

  3. New CZT cardiac cameras and myocardial perfusion imaging with thallium 201; Nouvelles cameras cardiaques a semi-conducteur cadmium -zinc- telluride (CZT) et scintigraphies myocardiques au thallium 201

    Energy Technology Data Exchange (ETDEWEB)

    Songy, B. [Service de medecine et imagerie nucleaire, centre cardiologique du Nord (CCN), 93 - Saint-Denis (France)

    2010-08-15

    Myocardial perfusion imaging is widely used for management of coronary artery disease. However, it suffers from technical limitations. New cardiac cameras using CZT detectors are now available and increase spatial (x2) and energy (x2) resolutions and photons sensitivity (x5). We describe here the General Electric Discovery NM 530c new camera and summarize the validation studies with technetium agents and with thallium 201, protocols to reduce doses, ultrafast protocols and perspectives offered with this new technology. (author)

  4. Septal myocardial perfusion imaging with thallium-201 in the diagnosis of proximal left anterior descending coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Pichard, A.D.; Wiener, I.; Martinez, E.; Horowitz, S.; Patterson, R.; Meller, J.; Goldsmith, S.J.; Gorlin, R.; Herman, M.V.

    1981-07-01

    The use of myocardial perfusion imaging (MPI) to identify obstructive coronary disease of the left anterior descending coronary artery proximal to the first septal perforator (prox LAD) was studied in 60 patients. Perfusion of the septum and anteroapical areas with thallium-201 injected during exercise was compared to results of coronary arteriography. Septal MPI defect was found in 92.3% of patients with obstruction of the proximal LAD, 27.7% of patients with obstruction of LAD distal to first septal perforator, 0% in patients with obstructions involving right or circumflex arteries, and in 10.5% of patients without coronary disease. Anteroapical MPI defects were found with similar frequency in the three groups with obstructive coronary disease. Septal MPI defect had a sensitivity of 92.3% and specificity of 85.4% in the diagnosis of proximal LAD disease. Normal septal perfusion with thallium-201 virtually excluded proximal LAD disease.

  5. Biphasic thallium 201 SPECT-imaging for the noninvasive diagnosis of myocardial perfusion abnormalities in a child with Kawasaki disease--a case report

    Energy Technology Data Exchange (ETDEWEB)

    Hausdorf, G.; Nienaber, C.A.; Spielman, R.P.

    1988-02-01

    The mucocutaneous lymph node syndrome (Kawasaki disease) is of increasing importance for the pediatric cardiologist, for coronary aneurysms with the potential of thrombosis and subsequent stenosis can develop in the course of the disease. The authors report a 2 1/2-year-old female child in whom, fourteen months after the acute phase of Kawasaki disease, myocardial infarction occurred. Biphasic thallium 201 SPECT-imaging using dipyridamole depicted anterior wall ischemia and inferolateral infarction. This case demonstrates that noninvasive vasodilation-redistribution thallium 201 SPECT-imaging has the potential to predict reversible myocardial perfusion defects and myocardial necrosis, even in small infants with Kawasaki disease.

  6. Reduced left ventricular cavitary activity ("black hole sign") in thallium-201 SPECT perfusion images of anteroapical transmural myocardial infarction.

    Science.gov (United States)

    Civelek, A C; Shafique, I; Brinker, J A; Durski, K; Weiss, J L; Links, J M; Natarajan, T K; Ozguven, M A; Wagner, H N

    1991-11-01

    Apparently reduced left ventricular (LV) cavitary thallium activity in both planar and tomographic perfusion images has been previously observed by these and other investigators. With single-photon emission computerized tomography, we have clinically noted that this "black hole sign" was associated with an aneurysm in the setting of a transmural anterior or anteroapical perfusion defect. We have now prospectively studied the etiology and predictive value of this sign in 84 consecutive patients with an anterior, anteroapical transmural perfusion defect. Of the 84 patients, 49 had both LV aneurysm (confirmed by contrast ventriculography, echocardiography or gated blood pool studies) and a black hole sign. Only 1 patient with an aneurysm did not have the black hole sign, and 2 without aneurysm did. Thus, it is concluded that this sign is highly accurate in diagnosing LV aneurysm. Because thallium-201 single-photon emission computerized tomography imaging is often performed as one of the first diagnostic tests soon after myocardial infarction, this has important clinical management implications.

  7. Myocardial perfusion defect on thallium-201 imaging in patients with chronic obstructive pulmonary disease

    Energy Technology Data Exchange (ETDEWEB)

    Mehrotra, P.P.; Weaver, Y.J.; Higginbotham, E.A.

    1983-08-01

    Six patients with angina pectoris had reversible perfusion defects on stress and redistribution thallium imaging. Three patients had a positive electrocardiographic response to exercise. No significant coronary artery lesions were seen on coronary arteriography in any of the six patients. All had mild to moderate hypoxemia at rest and physiologic evidence of chronic obstructive pulmonary disease as defined by the decrease in the ratio of forced expiratory volume at 1 second to forced vital capacity (FEV1/FVC X 100) or decrease in the forced midexpiratory flow rate (FEF25-75), or both. None had clinical findings suggestive of any of the reported causes of positive thallium scans in patients with normal coronary arteriograms. Cellular dysfunction produced by hypoxemia affecting the uptake of thallium seems to be the most likely mechanism of this abnormality.

  8. Functional significance of myocardial perfusion defects induced by dipyridamole using thallium-201 single-photon emission computed tomography and two-dimensional echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Jain, A.; Suarez, J.; Mahmarian, J.J.; Zoghbi, W.A.; Quinones, M.A.; Verani, M.S. (Baylor College of Medicine, Houston, TX (USA))

    1990-10-01

    The mechanisms responsible for inhomogeneous myocardial blood flow after oral administration of a large dose (300 mg) of dipyridamole were assessed in 27 patients with serial thallium-201 single-photon emission computed tomography (SPECT) and simultaneous 2-dimensional echocardiograms. Myocardial tomographic images were obtained 50 minutes and 3 to 4 hours after administration of dipyridamole. Two-dimensional echocardiograms were recorded at baseline and then every 15 minutes for 60 minutes. Dipyridamole caused only a mild reduction in blood pressure (from 129 +/- 18 to 126 +/- 16 mm Hg) and a mild increase in heart rate (from 69 +/- 15 to 73 +/- 4 beats/min). Sixteen patients had perfusion defects after dipyridamole by SPECT, which underwent partial or total filling-in. Fourteen of these patients (87.5%) had either a new abnormality or further deterioration of a preexisting wall motion abnormality by 2-dimensional echocardiography, and thus were considered to have developed transient ischemia during dipyridamole administration. Ten of 11 patients (91%) with normal perfusion or fixed defects by SPECT had no further deterioration in wall motion after oral dipyridamole, and were thus considered to have no evidence of myocardial ischemia. In conclusion, most patients with transient thallium-201 defects after dipyridamole develop transient worsening of resting wall motion by 2-dimensional echocardiography, suggestive of true myocardial ischemia. Because myocardial oxygen demand, as indicated by the heart rate-blood pressure product, did not change significantly, the mechanism of myocardial ischemia in these patients is likely to be diminished regional blood flow related to a subendocardial steal induced by dipyridamole.

  9. Serial thallium-201 imaging at rest in patients with unstable and stable angina pectoris: relationship of myocardial perfusion at rest to presenting clinical syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Brown, K.A.; Okada, R.D.; Boucher, C.A.; Phillips, H.R.; Strauss, H.W.; Pohost, G.M.

    1983-07-01

    In order to determine whether there are differences in myocardial perfusion at rest among patients with various unstable and stable angina syndromes, serial thallium-201 imaging was performed at rest in 19 patients presenting with rapidly worsening exertional angina (unstable angina, group A), 12 patients with rest angina alone without exertional symptoms (unstable angina, group B), and 34 patients with chronic stable angina. No patient had an episode of angina within 4 hours of study. Nineteen of 19 (100%) patients in group A demonstrated transient defects compared to only 3 of 12 (25%) patients in group B (p less than 0.0001) and 4 of 34 (12%) stable angina patients (p less than 0.0001). The majority of zones demonstrating transient defects in group A were associated with hypokinesis of the corresponding left ventriculogram segment without associated ECG evidence of previous infarction. There were no significant differences in the frequency of persistent thallium defects, severity of angiographic coronary artery disease, or frequency of regional wall motion abnormalities of myocardial segments supplied by stenotic coronary arteries among the three groups of patients. Transient defects have been shown to reflect reduction in regional coronary blood flow to viable myocardium. Therefore, we conclude that regional resting hypoperfusion of viable myocardium is far more common in patients with exertional unstable angina symptoms than in patients with rest angina alone or chronic stable angina.

  10. Thallium-201 is comparable to technetium-99m-sestamibi for estimating cardiac function in patients with abnormal myocardial perfusion imaging

    Directory of Open Access Journals (Sweden)

    Ming-Che Wu

    2015-11-01

    Full Text Available We analyzed the left-ventricular functional data obtained by cardiac-gated single-photon emission computed tomography myocardial perfusion imaging (MPI with thallium-201 (Tl-201 and technetium-99m-sestamibi (MIBI protocols in different groups of patients, and compared the data between Tl-201 and MIBI. Two hundred and seventy-two patients undergoing dipyridamole stress/redistribution Tl-201 MPI and 563 patients undergoing 1-day rest/dipyridamole stress MIBI MPI were included. Higher mean stress ejection fraction (EF, rest EF, and change in EF (ΔEF were noticed in the normal MPI groups by both Tl-201 and MIBI protocols. Higher mean EF was observed in the females with normal MPI results despite their higher mean age. Comparisons between the Tl-201 and MIBI groups suggested a significant difference in all functional parameters, except for the rest end diastolic volume/end systolic volume and ΔEF between groups with negative MPI results. For the positive MPI groups, there was no significant difference in all parameters, except for the change in end diastolic volume and change in end systolic volume after stress between both protocols. The Tl-201 provides comparable left-ventricular functional data to MIBI cardiac-gated single-photon emission computed tomography in patients with positive MPI results, and may therefore be undertaken routinely for incremental functional information that is especially valuable to this patient group.

  11. Comparison of 8-frame and 16-frame thallium-201 gated myocardial perfusion SPECT for determining left ventricular systolic and diastolic parameters.

    Science.gov (United States)

    Kurisu, Satoshi; Sumimoto, Yoji; Ikenaga, Hiroki; Watanabe, Noriaki; Ishibashi, Ken; Dohi, Yoshihiro; Fukuda, Yukihiro; Kihara, Yasuki

    2017-07-01

    The myocardial perfusion single photon emission computed tomography synchronized with the electrocardiogram (gated SPECT) has been widely used for the assessment of left ventricular (LV) systolic and diastolic functions using Quantitative gated SPECT. The aim of this study was to compare the effects of 8-frame and 16-frame thallium-201 (Tl-201) gated SPECT for determining LV systolic and diastolic parameters. The study population included 42 patients with suspected coronary artery disease who underwent gated SPECT by clinical indication. LV systolic and diastolic parameters were assessed on 8-frame and 16-frame gated SPECT. There were good correlations in end-diastolic volume (r = 0.99, p < 0.001), end-systolic volume (ESV) (r = 0.97, p < 0.001) and ejection fraction (EF) (r = 0.95, p < 0.001) between 8-frame and 16-frame gated SPECT. Bland-Altman plot showed a significant negative slope of -0.08 in EDV indicating a larger difference for larger EDV. Eight-frame gated SPECT overestimated ESV by 2.3 ml, and underestimated EF by -4.2% than 16-frame gated SPECT. There were good correlations in peak filling rate (PFR) (r = 0.87, p < 0.001), one third mean filling rate (r = 0.87, p < 0.001) and time to PFR (r = 0.61, p < 0.001) between 8-frame and 16-frame gated SPECT. Eight-frame gated SPECT underestimated PFR by -0.22 than 16-frame gated SPECT. Eight-frame gated SPECT estimated as much MFR/3 and TPFR as 16-frame gated SPECT. According to the data, the study suggested that 8-frame Tl-201 gated SPECT could underestimate systolic and/or diastolic parameter when compared with 16-frame gated SPECT.

  12. Early and delayed thallium-201 scintigraphy in thyroid nodules: the relationship between early thallium-201 uptake and perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Derebek, E. [Dept. of Nuclear Medicine, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Biberoglu, S. [Dept. of Internal Medicine, Div. of Endocrinology, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Kut, O. [Dept. of Nuclear Medicine, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Yesil, S. [Dept. of Internal Medicine, Div. of Endocrinology, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Saydam, S. [Dept. of Surgery, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Yilmaz, M. [Dept. of Nuclear Medicine, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Yenici, O. [Dept. of Nuclear Medicine, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Igci, E. [Dept. of Radiology, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Gokce, O. [Dept. of Surgery, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Canda, S. [Dept. of Pathology, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Bueyuekgebiz, A. [Dept. of Pediatrics, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Dogan, A.S. [Dept. of Nuclear Medicine, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey); Durak, H. [Dept. of Nuclear Medicine, Dokuz Eylul Univ., School of Medicine, Izmir (Turkey)

    1996-05-01

    Seventy-six patients with tyroid nodules were studied. Initially, 75 MBq of thallium-201 was injected. The thyroid gland was imaged 15 min (early) and 3 h (delayed) after the injection. Thereafter, 185 MBq technetium-99m pertechnetate was injected. Immediately after the injection, a 1-min perfusion image was acquired, followed by an image at 20 min. Increased early and delayed {sup 201}Tl uptake compared with the contralateral thyroid tissue was adopted as the criterion for malignancy. Sensitivity, specificity and negative predictive values were found to be 85%, 64% and 78%, respectively, in operated patients, but these values were 86%, 87% and 95%, respectively, in the whole group, including patients followed with fine-needle aspiration biopsy. With the purpose of investigating the relationship between perfusion and early {sup 201}Tl uptake, bot perfusion and early images were graded comparing nodular activity with contralateral thyroid activity. There was a poor correlation between perfusion and {sup 201}Tl uptake. The correlation was even worse in hyperactive nodules. It is concluded that early and delayed {sup 201}Tl imaging should not be used in the differential diagnosis of cold nodules and that early {sup 201}Tl uptake seems to be more closely related to factors other than perfusion. (orig.)

  13. Evaluation of myocardial damage in Duchenne's muscular dystrophy with thallium-201 myocardial SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Tamura, Takuhisa; Shibuya, Noritoshi (Kawatana National Hospital, Nagasaki (Japan)); Hashiba, Kunitake; Oku, Yasuhiko; Mori, Hideki; Yano, Katsusuke

    1993-01-01

    Myocardial damage and cardiopulmonary functions in patients with Duchenne's muscular dystrophy (DMD) were assessed using thallium-201 myocardial single-photon emission computed tomography (SPECT) and technetium-99m multigated radionuclide angiography. Twenty-five patients with DMD were divided into 4 groups according to percent of perfusion defect (%PD) calculated by the bull's-eye method and age. PD was detected in 24 (96.0%) of 25 patients with DMD, and it spread from the left ventricular lateral wall to the anterior wall and/or interventricular septum. PD was detected even in a 6-year-old DMD boy. Patients in Group I (%PD[>=]10% and age<15 years old) were shown to have a higher risk of left-sided heart failure without respiratory failure. Patients in Group II (%PD[>=]10 and age[>=]15) showed decreased pulmonary function and worsened arterial blood gas values as compared with Group IV (%PD<10 and age[>=]15). There was no significant difference in cardiac function among the 4 groups. It is postulated that myocardial damage in Group II patients is dependent primarily on a deficiency of dystrophin and on chronic respiratory failure, and that some of them are at risk of cardiopulmonary failure. It is concluded that myocardial SPECT is useful for the early diagnosis of myocardial damage and evaluation of cardiopulmonary function in DMD patients. (author).

  14. Indium-111 antimyosin antibody imaging and thallium-201 imaging. A comparative myocardial scintigraphic study using single-photon emission computed tomography in patients with myocarditis and dilated cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Takehiko; Matsumori, Akira; Nohara, Ryuji; Konishi, Junji; Sasayama, Shigetake [Kyoto Univ. (Japan). Faculty of Medicine; Tamaki, Nagara

    1997-10-01

    Indium-111 antimyosin antibody imaging (a tracer of myocardial necrosis) and thallium-201 imaging (a tracer of myocardial perfusion) were compared in patients with myocarditis and dilated cardiomyopathy. The distribution of each tracer and antimyosin/thallium-201 overlapping were evaluated with single-photon emission computed tomography (SPECT). Scintigraphic data were classified into 5 patterns according to the distribution of both images and were compared with histologic findings of endomyocardial biopsy: AM-D, intense and diffuse antimyosin uptake and no perfusion abnormality (active myocarditis); AM-L, localized antimyosin uptake and no perfusion abnormality (active myocarditis); HM, no antimyosin uptake with or without perfusion abnormality (healed myocarditis); DCM-NH, diffuse antimyosin uptake and inhomogeneous thallium-201 uptake (dilated cardiomyopathy); DCM-PD, diffuse or localized antimyosin uptake and myocardial perfusion defect(s) (dilated cardiomyopathy). Patients with dilated-phase hypertrophic cardiomyopathy were frequently found in the DCM-PD group. Taken together, comparative antimyosin/thallium-201 SPECT images are useful for evaluating the activity of myocarditis and ongoing myocardial damage even in areas with no perfusion in patients with dilated cardiomyopathy. (author)

  15. Identification of advanced coronary artery disease with exercise myocardial perfusion imaging: the clinical value of a novel approach for assessing lung thallium-201 uptake

    Energy Technology Data Exchange (ETDEWEB)

    Moralidis, Efstratios [Hippokration Hospital, Nuclear Medicine Department, Thessaloniki (Greece); Hippokration Medical Center, Larissa (Greece); Spyridonidis, Tryfon [Hippokration Medical Center, Larissa (Greece); Arsos, Georgios [Hippokration Hospital, Nuclear Medicine Department, Thessaloniki (Greece); Anagnostopoulos, Constantinos [Royal Brompton Hospital, Nuclear Medicine Department, London (United Kingdom)

    2007-04-15

    The precise clinical utility of lung{sup 201}Tl uptake in exercise SPECT myocardial perfusion imaging remains open to research. This study validates an optimal index for lung{sup 201}Tl uptake measurement and assesses its value in the prediction of higher-risk coronary artery disease (CAD). Three hundred and ninety-eight patients underwent exercise SPECT myocardial perfusion imaging. They were separated into derivation (n = 217) and validation (n = 186) groups, both including sub-populations of lower- and higher-risk CAD, according to coronary angiography. Another 56 individuals with a low probability of CAD comprised the control group. From a planar, anterior, post-exercise acquisition, the lung (L) to heart (H) maximal (L/H{sub max}), total (L/H{sub mean}) and background-subtracted total (L/H{sub net}) ratios were calculated. These were also adjusted for confounding variables, as assessed from the control group. ROC analysis was used to compare the L/H ratios and define thresholds of abnormality. The performance of the optimal index was assessed in the derivation group and was then tested in the validation population. Subsequently, it was compared with other scintigraphic, exercise electrocardiography and clinical variables. In the derivation group L/H{sub net} was a better discriminator for higher-risk CAD than both L/H{sub max} and L/H{sub mean}. Similarly, the adjusted L/H{sub net} was a better discriminator than both the adjusted L/H{sub max} and the adjusted L/H{sub mean}. No significant difference was attained between L/H{sub net} and the adjusted L/H{sub net}. At the upper defined threshold of abnormality, sensitivity and specificity of L/H{sub net} in the detection of higher-risk CAD in the derivation and the validation cohorts were 52% and 92% versus 47% and 94%, respectively (p = ns). The results were similar at other defined thresholds. Moreover, L/H{sub net} was found to be a significant predictor of higher-risk CAD, superior to myocardial perfusion

  16. Evaluation of myocardial abnormalities in collagen diseases by thallium-201 myocardial scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Yamano, Shigeru; Kagoshima, Tadashi; Sugihara, Kiyotaka (Nara Medical Univ., Kashihara (Japan)) (and others)

    1993-12-01

    This study was performed to evaluate myocardial abnormalities in patients with collagen diseases by exercise and rest thallium-201 myocardial scintigrams. A total of 65 patients without ischemic ECG changes, consisting of 18 with systemic lupus erythematosus (SLE), 18 with polymyositis (PM), 8 with progressive systemic sclerosis (PSS), and 21 with Sjoegren's syndrome (SjS), was enrolled in this study. Reversible exercise-induced defects scintigraphically suggesting myocardial ischemia were noted in 8 cases of SLE, 4 cases of PM, 4 cases of PSS, and 3 cases of SjS. Nineteen patients had exercise-induced defects and underwent cardiac catheterization, 8 of whom had normal coronary angiograms. Fixed hypoperfusion areas were observed in one case of SLE, 6 cases of PM and 3 cases of SjS. Rest thallium-201 myocardial scintigram disclosed hypoperfusion areas which were not induced by exercise in 2 cases of SLE, 3 cases of PM, one case of PSS and 5 cases of SjS. Echocardiogram showed no significant differences in ejection fraction and % fractional shortening between the disease groups and healthy control group. These findings suggest that patients with collagen diseases have abnormalities of coronary circulation at the level of the intramural vasculature before cardiac function impairment, myocardial fibrosis and functional abnormalities at the cell membrane. (author).

  17. Comparative studies on right ventricular pressure and volume overloading by thallium-201 myocardial scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Owada, K.; Tsukahara, Y.; Kijima, M.; Miyazaki, Y.; Ono, K. (Fukushima Medical Coll. (Japan))

    1982-03-01

    Thallium-201 myocardial scintigraphy was performed in 44 patients with various heart diseases including mitral stenosis, atrial septal defect, primary pulmonary hypertension, and left atrial myxoma. The morphological findings of right ventricular (RV) free wall on the scintigram and RV/IVS (interventricular septum) uptake ratio of the images obtained from the left anterior oblique projection were studied in the patients with RV pressure or volume overloading.

  18. Evaluation of myocardial abnormalities in patients with collagen diseases by thallium-201 myocardial scintigram

    Energy Technology Data Exchange (ETDEWEB)

    Yamano, Shigeru (Nara Medical Univ., Kashihara (Japan))

    1992-08-01

    This study was performed to evaluate myocardial lesions in patients with collagen diseases by rest and exercise thallium-201 myocardial scintigraphies. A total of 76 patients without ischemic ECG changes, consisting of 27 cases of systemic lupus erythematosus (SLE), 17 cases of polymyositis or dermatomyositis (PM[center dot]DM), 11 cases of progressive systemic sclerosis (PSS), and 21 cases of Sjoegren's syndrome (SjS), were enrolled in this study. Reversible exercise-induced defects suggesting myocardial ischemia were noted in 12 cases of SLE, 5 cases of PM[center dot]DM, 3 cases of PSS, and 3 cases of SjS. Of the 23 patients who had exercise-induced defects, 9 patients showed normal coronary angiograms by cardiac catheterization. Fixed hypoperfusion areas were observed in 5 cases of SLE, 6 cases of PM[center dot]DM, 4 cases of PSS and 3 cases of SjS. Rest thallium-201 myocardial scintigraphy disclosed hypoperfusion areas, which were not induced by exercise, in 1 case of SLE, 4 cases of PM[center dot]DM, 1 case of PSS and 5 cases of SjS. Endomyocardial biopsy was performed on 20 patients. Myocardial lesions in PM[center dot]DM and PSS were more severe and wide spread than in SLE. Ejection fraction and fractional shortening evaluated by echocardiography had no significant differences between each disease group and the healthy control group. These findings suggest that patients with collagen diseases show the presence of abnormalities of coronary circulation at the level of the intramyocardial vasculature in the stage before impairment of cardiac function, myocardial fibrosis and functional abnormalities of the cell membrane level that were not dependent on myocardial ischemia. (author).

  19. Qualitative evaluation of coronary flow during anesthetic induction using thallium-201 perfusion scans

    Energy Technology Data Exchange (ETDEWEB)

    Kleinman, B.; Henkin, R.E.; Glisson, S.N.; el-Etr, A.A.; Bakhos, M.; Sullivan, H.J.; Montoya, A.; Pifarre, R.

    1986-02-01

    Qualitative distribution of coronary flow using thallium-201 perfusion scans immediately postintubation was studied in 22 patients scheduled for elective coronary artery bypass surgery. Ten patients received a thiopental (4 mg/kg) and halothane induction. Twelve patients received a fentanyl (100 micrograms/kg) induction. Baseline thallium-201 perfusion scans were performed 24 h prior to surgery. These scans were compared with the scans performed postintubation. A thallium-positive scan was accepted as evidence of relative hypoperfusion. Baseline hemodynamic and ECG data were obtained prior to induction of anesthesia. These data were compared with the data obtained postintubation. Ten patients developed postintubation thallium-perfusion scan defects (thallium-positive scan), even though there was no statistical difference between their baseline hemodynamics and hemodynamics at the time of intubation. There was no difference in the incidence of thallium-positive scans between those patients anesthetized by fentanyl and those patients anesthetized with thiopental-halothane. The authors conclude that relative hypoperfusion, and possibly ischemia, occurred in 45% of patients studied, despite stable hemodynamics, and that the incidence of these events was the same with two different anesthetic techniques.

  20. Sequential thallium-201 myocardial scintigraphy after acute infarction in man

    Energy Technology Data Exchange (ETDEWEB)

    Fletcher, J.W.; Mueller, H.S.; Rao, P.S.

    1980-07-01

    Three sequential Tl-201 myocardial perfusion studies were performed in 21 patients (18 men, 3 women) with first acute transmural myocardia infarction. The Tl-201 image defect size was determined with a semiquantitative visual scoring method and temporal changes in image defect size were compared to CK-MB infarct size and enzymatic evidence of progressive myocardial necrosis and infarct extension. Progressive decreases in Tl-201 image defect size were observed and the visual score in all 21 patients decreased significantly from 6.5 +- 3.7 (mean +- SD) on day 1 to 4.9 +- 3.5 on day 12. Eleven patients without evidence of infarct extension had significantly lower infarct size, a significant decrease in visual score by the 12th day and had significantly smaller Tl-201 defects at all three study times compared to 10 patients with infarct extension. Seven of 10 (70%) with extension had an initial visual score greater than or equal to 7 compared to only 2/11 (18%) without extension. The temporal behavior of Tl-201 image defects is related to the size of the infarction and presence or absence of extension. Sequential studies comparing early initial and subsequent defect size may assist in evaluating the behavior of ischemic and infarcted myocardium in the postinfarction period.

  1. Clinicopathologic correlation study of thallium-201 myocardial scintigraphy in diagnosis of myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Chida, Kouji; Sugiura, Masaya; Ohkawa, Shin-ichiro

    1987-05-01

    In a series of 1,000 consecutive autopsy cases, we evaluated the clinical utility of thallium-201 (Tl-201) myocardial scintigraphy and electrocardiography (ECG) in 101 patients who had been studied while alive. Fifty-five cases had myocardial infarctions (MI) at autopsy. The Tl-201 scintigram and ECG in diagnosis of MI showed sensitivities of 68 % and 60 %, specificities of 87 % and 83 %, and diagnostic accuracies of 76 % and 70 %, respectively. The sensitivity of the Tl-201 scintigram was 70 % in anterior MI, 80 % in postero-inferior MI, 25 % in lateral and subendocardial infarction. The sensitivity was 88 % for large massive MI, but was low in scattered (50 %) or middle-sized MI (17 %). The diagnostic limit of the resolution of Tl-201 scintigrams was 4.5 cm in long diameter. All 8 cases with MI of less than 4 cm could not be diagnosed with the technique. There were 48 cases of large MI (more than 5 cm), but 8 cases could not be diagnosed by scintigraphy because of non-transmural or scattered MI. A comparison of the Tl-201 scintigram and ECG showed that 27 cases out of 60 cases were diagnosed by both methods, 14 only by the Tl-201 scintigram, 9 only by ECG and 10 by neither method.

  2. Effect of long-term cholesterol-lowering treatment with HMG-CoA reductase inhibitor (Simvastatin) of myocardial perfusion evaluated by thallium-201 single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Hosokawa, Ryohei; Nohara, Ryuji; Linxue, Li; Sasayama, Shigetake [Kyoto Univ. (Japan). Graduate School of Medicine; Tamaki, Shunichi; Hashimoto, Tetsuo; Tanaka, Masahiro; Miki, Shinji

    2000-03-01

    Fifteen patients with either angina pectoris or old myocardial infarction, who had positive {sup 201}Tl single photon emission computed tomography (SPECT) imaging and coronary sclerosis of more than 50%, were treated with an HMG-CoA reductase inhibitor (simvastatin) for more than 1 year. They were compared with an untreated control group (n=25). Total cholesterol decreased 22% and high-density lipoprotein (HDL) increased 9% with simvastatin; both changes were significantly different from those in controls. Long-term simvastatin induced improvement of myocardial perfusion on {sup 201}Tl SPECT images both during exercise and at rest, which was also significantly different from controls. In addition, the improvement of myocardial perfusion on {sup 201}Tl SPECT images was clearly related to the improvements in cholesterol values, especially nonHDL cholesterol. Thus, the greater the decrease in nonHDL cholesterol, the greater the improvement in myocardial perfusion at rest or during exercise with long-term treatment using an HMG-CoA reductase inhibitor. These findings indicate that the improvements in cholesterol values caused by HMG-CoA reductase inhibitor therapy are related to improvements of myocardial perfusion seen on {sup 201}Tl SPECT images. (author)

  3. Quantitative evaluation of thallium-201 myocardial scintigram in coronary artery diseases

    Energy Technology Data Exchange (ETDEWEB)

    Mikada, Ken-etsu (Akita Univ. (Japan). School of Medicine)

    1992-11-01

    Quantitative indices from circumferential profile curves of thallium-201 ([sup 201]Tl) myocardial scintigram were evaluated for diagnostic utility in coronary artery diseases (CAD). Myocardial [sup 201]Tl scintigrams with single photon emission computed tomography (SPECT) were obtained 5 minutes (early) and 4 hours (delayed) after exercise in 20 normal subjects and 66 cases of CAD, of which 20 were angina pectoris without myocardial infarction (AP), 14 were subendocardial infarction (non-QMI) and 32 were Q-wave infarction (QMI). Tl counts, %Tl uptake and washout ratio (WR) were measured in 81 segments (9 apical segments of the slice from the longitudinal axis and all 72 segments of two slices from the short axis). A mean early defect (MED), a mean delayed defect (MDD), a mean delta washout rate (MDR), and a [Sigma] delayed defect ([Sigma]DD) were calculated from the areas which were below the two standard deviations of the mean %Tl uptake in normal subjects. A mean filling-in (MFI) was calculated from the difference of the %Tl uptake between early and delayed curves in each patient. In patients with CAD, the MED and MFI were higher, but MDW was lower with a more severe coronary stenosis, indicating that these indices were useful to detect myocardial hypo-perfuion. In severely stenotic regions, the MDD was higher in QMI than in AP and non-QMI, indicating that the ratio of infarct to the myocardium in the region was higher in QMI. In QMI, [Sigma]DD correlated well (r=0.723) with Total Wall Motion Scores with two-dimentional echocardiography which was directly related with infarct size. Further, MED, MFI and MDW were improved after aortocoronary bypass only in patients with patent graft. It is concluded that this quantitative evaluation with [sup 201]Tl-SPECT can provide an objective and quantitative estimate of regional myocardial ischemia and infarct. (author).

  4. Thallium-201 myocardial scintigraphy in patients with normal coronary arteries and normal left ventriculogram. Comparison with hemodynamic, metabolic and morphologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Loesse, B.; Kuhn, H.; Rafflenbeul, D.; Kroenert, H.; Hort, W.; Feinendegen, L.E.; Loogen, F.

    1980-01-01

    36 consecutive patients with chest pain and/or severe ventricular dysrhythmias, but normal coronary arteries and normal left ventriculogram, underwent thallium-201 myocardial imaging at rest and during exercise. The myocardial scintigram was abnormal in 27 patients (group A) and normal in only 9 patients (group B).

  5. Diagnostic value of thallium-201 myocardial perfusion IQ-SPECT without and with computed tomography-based attenuation correction to predict clinically significant and insignificant fractional flow reserve: A single-center prospective study.

    Science.gov (United States)

    Tanaka, Haruki; Takahashi, Teruyuki; Ohashi, Norihiko; Tanaka, Koichi; Okada, Takenori; Kihara, Yasuki

    2017-12-01

    The aim of this study was to clarify the predictive value of fractional flow reserve (FFR) determined by myocardial perfusion imaging (MPI) using thallium (Tl)-201 IQ-SPECT without and with computed tomography-based attenuation correction (CT-AC) for patients with stable coronary artery disease (CAD).We assessed 212 angiographically identified diseased vessels using adenosine-stress Tl-201 MPI-IQ-SPECT/CT in 84 consecutive, prospectively identified patients with stable CAD. We compared the FFR in 136 of the 212 diseased vessels using visual semiquantitative interpretations of corresponding territories on MPI-IQ-SPECT images without and with CT-AC.FFR inversely correlated most accurately with regional summed difference scores (rSDS) in images without and with CT-AC (r = -0.584 and r = -0.568, respectively, both P < .001). Receiver-operating characteristics analyses using rSDS revealed an optimal FFR cut-off of <0.80 without and with CT-AC. Although the diagnostic accuracy of FFR <0.80 did not significantly differ, FFR ≥0.82 was significantly more accurate with, than without CT-AC. Regions with rSDS ≥2 without or with CT-AC predicted FFR <0.80, and those with rSDS ≤1 without and with CT-AC predicted FFR ≥0.81, with 73% and 83% sensitivity, 84% and 67% specificity, and 79% and 75% accuracy, respectively.Although limited by the sample size and the single-center design, these findings showed that the IQ-SPECT system can predict FFR at an optimal cut-off of <0.80, and we propose a novel application of CT-AC to MPI-IQ-SPECT for predicting clinically significant and insignificant FFR even in nonobese patients. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  6. Myocardial scintigraphy with iodine-123 phenylpentadecanoic acid and thallium-201 in patients with coronary artery disease: A comparative dual-isotope study

    Energy Technology Data Exchange (ETDEWEB)

    Zimmermann, R.; Rauch, B.; Kapp, M.; Neumann, F.J.; Seitz, F.; Kuebler, W. (Heidelberg Univ. (Germany). Dept. of Cardiology); Bubeck, B. (Heidelberg Univ. (Germany). Dept. of Nuclear Medicine); Mall, G. (Heidelberg Univ. (Germany). Dept. of Pathology); Tillmanns, H. (Giessen Univ. (Germany). Dept. of Cardiology); Stokstad, P.

    1992-11-01

    To characterise the clinical usefulness of serial myocardial scintigraphy with iodine-123 phenylpentadecanoic acid (IPPA) in comparison with thallium-201, dual-isotope investigations were performed in 41 patients with angiographically documented coronary artery disease. Both tracers were adminstered simultaneously during symptom-limited ergometry. Planar scintigrams were acquired immediately after stress, and delayed imaging was performed after 1 h for IPPA and 4 h for {sup 201}Tl. Scintigrams were evaluated both qualitatively and quantitatively using a newly developed algorithm for automated image superposition. Initial myocardial uptake of both tracers was closely correlated (r=0.75, p<0.001). Both tracers also revealed a similar sensitivity for the identification of individual coronary artery stenoses {>=}75% (IPPA: 70%, {sup 201}Tl: 66.3%, P=NS) with identical specificity (69.8%). The number of persistent defects, however, was significantly higher with IPPA (P=0.021), suggesting that visual analysis of serial IPPA scintigrams may overestimate the presence of myocardial scar tissue. On the other hand, previous Q wave myocardial infarction was associated with a decreased regional IPPA clearance (29%{+-}11% vs 44%{+-}11% in normal myocardium, P<0.05). The data indicate that serial myocardial scintigraphy with IPPA is essentially as sensitive as scintigraphy with {sup 201}Tl for the detection of stress-induced perfusion abnormalities. Quantitative analysis of myocardial IPPA kinetics, however, is required for the evaluation of tissue viability. (orig.).

  7. Myocardial scintigraphy with iodine-123 phenylpentadecanoic acid and thallium-201 in patients with coronary artery disease: a comparative dual-isotope study.

    Science.gov (United States)

    Zimmermann, R; Rauch, B; Kapp, M; Bubeck, B; Neumann, F J; Seitz, F; Stokstad, P; Mall, G; Tillmanns, H; Kübler, W

    1992-01-01

    To characterise the clinical usefulness of serial myocardial scintigraphy with iodine-123 phenylpentadecanoic acid (IPPA) in comparison with thallium-201, dual-isotope investigations were performed in 41 patients with angiographically documented coronary artery disease. Both tracers were administered simultaneously during symptom-limited ergometry. Planar scintigrams were acquired immediately after stress, and delayed imaging was performed after 1 h for IPPA and 4 h for 201Tl. Scintigrams were evaluated both qualitatively and quantitatively using a newly developed algorithm for automated image superposition. Initial myocardial uptake of both tracers was closely correlated (r = 0.75, p or = 75% (IP-PA: 70.0%, 201Tl: 66.3%, P = NS) with identical specificity (69.8%). The number of persistent defects, however, was significantly higher with IPPA (P = 0.021), suggesting that visual analysis of serial IPPA scintigrams may overestimate the presence of myocardial scar tissue. On the other hand, previous Q wave myocardial infarction was associated with a decreased regional IPPA clearance (29% +/- 11% vs 44% +/- 11% in normal myocardium, P IPPA is essentially as sensitive as scintigraphy with 201Tl for the detection of stress-induced perfusion abnormalities. Quantitative analysis of myocardial IPPA kinetics, however, is required for the evaluation of tissue viability.

  8. Comparative study of body surface isopotential map, left ventriculogram and thallium-201 myocardial scintigram in patients with old lateral myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Naoyuki

    1988-01-01

    In 16 patients with old lateral myocardial infarction, body surface isopotential maps and 12 lead electrocardiograms were compared with left ventriculographic findings. In addition 8 of these subjects were performed thallium-201 myocardial scintigraphy in order to determine the location and extent of myocardial necrosis. Common 12 lead electrocardiographic findings of the subjects were initial Q waves more than 30 msec and inverted T waves in only aVL lead. The patients were classified into 4 groups according to the location and extent of ventricular wall motion abnormalities group I (6 cases) showed hypokinesis in the anterior segment, group II (5 cases): akinesis in the anterior segment and hypokinesis in the seg. 6, group III (4 cases): hypokinesis in the anterior segment and seg. 7, group IV (1 case): hypokinesis in the anterior segment and seg. 4, 7. And each of the 4 groups demonstrated characteristic findings of surface isopotential maps. Group II with coexisting hypokinesis in the seg. 6 showed surface isopotential maps additional pattern of anterior myocardial infarction, and group III with coexisting hypokinesis in the seg. 7 showed additional patterns of posterior myocardial infarction. The classification according to the abnormality of ventricular wall motion was also conformed with the thallium-201 myocardial scintigraphic findings except one case. These results suggest that body surface isopotential map is more useful than the 12 lead electrocardiogram in detecting the location and extent of left ventricular wall motion abnormality in patients with old lateral myocardial infarction. (author) 53 refs.

  9. Disease stage classification in hypertrophic cardiomyopathy by dual analysis of iodine-123-labeled metaiodobenzylguanidine and thallium-201 myocardial scintigraphies

    Energy Technology Data Exchange (ETDEWEB)

    Hiasa, Go [Ehime Univ., Matsuyama (Japan). School of Medicine

    2001-08-01

    Many patients with hypertrophic cardiomyopathy (HCM) gradually changes from typical myocardial hypertrophy to dilated cardiomyopathy-like features. However, it is difficult to estimate the disease stage in HCM. To determine the disease stage, dual analysis of iodine-123-labeled metaiodobenzylguanidine ({sup 123}I-MIBG) and thallium-201 ({sup 201}Tl) myocardial scintigraphies were performed in 108 HCM patients. According to the scintigraphic distribution patterns, patients were divided into three groups. Group A (n=15): normal distributions of both {sup 123}I-MIBG and {sup 201}Tl, group B (n=71): normal {sup 201}Tl and low {sup 123}I-MIBG patterns, group C (n=22): low distributions of both scintigraphies. The decrease in {sup 201}Tl uptake was observed in only group C. Concerning {sup 123}I-MIBG, heart-to-mediastinum ratio (H/M) and washout rate (WOR) had good correlations with left ventricular systolic functions. H/M was decreased and WOR was increased in order of C, B and A groups. Left ventricular diastolic function reflected by isovolumic relaxation time was longer in group B than in group A. Attenuated left ventricular hypertrophy, enlarged left ventricular volumes, impaired left ventricular functions and serious clinical symptoms were observed in only group C. Myocardial sympathetic abnormalities in group B may be mainly due to myocardial hypertrophy, and those in group C may be due to myocardial injury. Dual analysis of {sup 123}I-MIBG and {sup 201}Tl scintigraphies may be useful to classify disease stages of HCM. (author)

  10. Myocardial infarction diagnosis with body surface potential mapping, electrocardiography, vectorcardiography and thallium-201 scintigraphy: a correlative study with left ventriculography.

    Science.gov (United States)

    Ackaoui, A; Nadeau, R; Sestier, F; Savard, P; Primeau, R; Lemieux, R; Descary, M C

    1985-01-01

    In 35 subjects with typical or atypical angina and/or documented myocardial infarction (MI), body surface potential maps (BSPMs), ECG, VCG and rest Thallium-201 (T1-201) have been compared to left ventriculography (LVG). BSPMs were recorded with 26 ECGs, and BSPM abnormalities for MI cases were considered to be areas of normally positive potentials that have become negative. Subjects with MI were classified according to the segmental localization and degree of asynergy on LVG. Moderate anterolateral and apical asynergy were found to correlate with BSPM diagnosis of anterolateral MI and ischemia, severe anterolateral and apical asynergy with BSPM diagnosis of anterolateral MI and ischemia, and moderate diaphragmatic and/or posterobasal asynergy with BSPM diagnosis of posterior MI. Simultaneous anterior and posterior asynergy were found for BSPM diagnosis of anterior with posterior MI. Subjects with no LVG asynergy had normal BSPMs. BSPM diagnosis had the highest correlation coefficient with the LVG diagnosis (r = 0.88). ECG and VCG showed similar results with r = 0.65 and 0.71 respectively, while T1-201 had r = 0.55. The examination of our BSPMs, as well as the ECG, VCG and T1-201, did not permit to detect apical damage in presence of anterior MI, and posterobasal damage in the presence of inferoposterior MI. It is concluded that BSPMs are slightly superior to ECG and VCG for diagnosis of MI.

  11. Technetium-99m pyrophosphate/thallium-201 dual-isotope SPECT imaging predicts reperfusion injury in patients with acute myocardial infarction after reperfusion

    Energy Technology Data Exchange (ETDEWEB)

    Akutsu, Yasushi; Kaneko, Kyouichi; Kodama, Yusuke; Li, Hui-Ling; Nishimura, Hideki; Hamazaki, Yuji; Kobayashi, Youichi [Showa University School of Medicine, Division of Cardiology, Department of Medicine, Tokyo (Japan); Suyama, Jumpei; Shinozuka, Akira; Gokan, Takehiko [Showa University School of Medicine, Department of Radiology, Tokyo (Japan)

    2009-02-15

    Microcirculatory failure after reperfusion is clinically indicated to cause reperfusion injury whereas excessive intracellular calcium ion overload is experimentally proved as a key mechanism of reperfusion injury. We hypothesized that technetium-99m ({sup 99m}Tc) pyrophosphate (Tc-PYP) uptake in injured but viable infarct-related myocardium with preserved myocardial perfusion after reperfusion estimated by thallium-201 ({sup 201}Tl) uptake would be associated with final functional recovery. Dual-isotope Tc-PYP/{sup 201}Tl single-photon emission computed tomography (SPECT) was performed 2 days after successful reperfusion therapy in patients with first acute myocardial infarction, and 50 patients (63 {+-} 13 years old, female 22%) with preserved {sup 201}Tl uptakes of {>=}50% in reperfused myocardium was followed for 1 month. Tc-PYP uptake was assessed as the heart-to-sternum (H/S) ratio. Two-dimensional echocardiography was also performed 2 days and 1 month after reperfusion to evaluate functional recovery. High Tc-PYP uptake, defined as the H/S ratio {>=}0.81, was predictive of chronic phase no functional recovery (73.7% in 14 of 19 patients with high uptake vs 16.1% in five of 31 patients without those, p < 0.0001). After adjustment for potential confounding variables, including electrocardiographic persistent ST segment elevation at 1 h after reperfusion, high Tc-PYP uptake remained independently predictive of no functional recovery with odds ratio of 8.7 (95% confidential interval = 2 to 38.7; p = 0.005). High Tc-PYP uptake in reperfused but viable infarct-related myocardium was a powerful predictor of no functional recovery, which may reflect excessive intracellular calcium ion overload caused by reperfusion injury. Tc-PYP/{sup 201}Tl dual-isotope SPECT imaging can provide prognostic information after reperfusion. (orig.)

  12. Assessment of myocardial viability by exercise stress-redistribution myocardial scintigraphy with thallium-201; The usefulness of C-map

    Energy Technology Data Exchange (ETDEWEB)

    Narita, Michihiro; Kurihara, Tadashi; Murano, Kenichi; Usami, Masahisa (Sumitomo Hospital, Osaka (Japan))

    1993-09-01

    This study was intended to clarify whether Tl-201 washout rate abnormality after exercise stress can detect myocardial viability in the myocardium with perfusion defect on redistribution (RD) images. The subjects were 29 patients with ischemic heart disease in whom perfusion defect was seen on delayed (3 hr) RD images and had percutaneous transluminal coronary angioplasty (PTCA). A combined map (C-map) was prepared by adding the location of washout rate abnormality ([<=]30%) to perfusion defect on RD images before PTCA. The C-map and myocardial images after PTCA (Post-map) were compared. The left ventriculogram was divided into 17 segments. C-map and Post-map were qualitatively concordant with each other in 27 of 29 patients (93%). In the other 2 patients, only one segment showed discordance of findings between the two maps. Out of 152 segments with perfusion defect on RD images, 75 segments (50%) showed normal perfusion in both the C-map and the Post-map. In segmental analysis, the C-map and the Post-map were found consistent in 80% of the cases. In 12 patients with fixed defect before PTCA, the agreement between the C-map and the Post-map was also excellent (86%). The present C-map was useful for not only qualitative but also quantitative analyses of myocardial viability in myocardial segments which show perfusion defect on standard RD images. (N.K.).

  13. Protocols of myocardial perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seong Min [College of Medicine, Chungnam National University, Daejeon (Korea, Republic of)

    2005-02-15

    In myocardial perfusion scintigraphy, the results of this evaluation now confront the practitioner of nuclear medicine with methodological options. Most nuclear cardiologic studies are performed using thallium-201, Tc-99m sestamibi and Tc-99m tertrofosmin. Some part of these studies use some form of pharmacologic stress test. While tailoring each test to the individual is ideal, this may be impractical for a busy department. Accordingly, established protocols to be used for patients with similar clinical presentations will be helpful. The following review presents methodology of various imaging protocols mainly according to the guidelines of nuclear cardiology procedures in American Society of Nuclear Cardiology.

  14. Relationship between thallium-201 myocardial SPECT and findings of endomyocardial biopsy specimens in dilated cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Motohiro; Gotoh, Kohshi; Nagashima, Kenshi [Gifu Univ. (Japan). School of Medicine] (and others)

    2001-02-01

    The purpose of this study was to clarify which myocardial histological findings associated with dilated cardiomyopathy (DCM) are reflected in quantitative {sup 201}Tl myocardial SPECT. We obtained studied SPECT images from 21 patients with DCM 10 minutes and 2 hours after they received an injection of 111 MBq {sup 201}Tl at rest. We calculated the percent coefficient of variation of myocardial {sup 201}Tl counts [%CV(Tl)], the washout rate (WR), standard deviation of WR [SD(WR)], extent score (ES) and severity score (SS). We used image analysis to measure % fibrosis, % myocytes, the ratio of fibrous tissue to myocyte tissue (F/My), myocyte size and standard deviation of myocyte size [SD(My)] in left ventricular endomyocardial biopsy specimens. The %CV(Tl) was correlated with % fibrosis and F/My. The ES and SS also correlated with F/My. The correlation between SD(WR) and SD(My) was significant. The present findings suggest that %CV(Tl), ES and SS of rest {sup 201}Tl SPECT reflect myocardial fibrosis and that the standard deviation of washout reflects the distribution of myocyte size. (author)

  15. Pentoxifylline (Trental) does not inhibit dipyridamole-induced coronary hyperemia: Implications for dipyridamole-thallium-201 myocardial imaging

    Energy Technology Data Exchange (ETDEWEB)

    Brown, K.A.; Slinker, B.K. (Univ. of Vermont College of Medicine, Burlington (USA))

    1990-06-01

    Dipyridamole-thallium-201 imaging is often performed in patients unable to exercise because of peripheral vascular disease. Many of these patients are taking pentoxifylline (Trental), a methylxanthine derivative which may improve intermittent claudication. Whether pentoxifylline inhibits dipyridamole-induced coronary hyperemia like other methylxanthines such as theophylline and should be stopped prior to dipyridamole-thallium-201 imaging is unknown. Therefore, we studied the hyperemic response to dipyridamole in seven open-chest anesthetized dogs after pretreatment with either pentoxifylline (0, 7.5, or 15 mg/kg i.v.) or theophylline (3 mg/kg i.v.). Baseline circumflex coronary blood flows did not differ significantly among treatment groups. Dipyridamole significantly increased coronary blood flow before and after 7.5 or 15 mm/kg i.v. pentoxifylline (p less than 0.002). Neither dose of pentoxifylline significantly decreased the dipyridamole-induced hyperemia, while peak coronary blood flow was significantly lower after theophylline (p less than 0.01). We conclude that pentoxyifylline does not inhibit dipyridamole-induced coronary hyperemia even at high doses.

  16. Usefulness and limitations of thallium-201 myocardial scintigraphy in delineating location and size of prior myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Niess, G.S.; Logic, J.R.; Russell, R.O. Jr.; Rackley, C.E.; Rogers, W.J.

    1979-05-01

    Thirty-two patients were evaluated at a mean of 7 +- 2 months after infarction with a 12-lead ECG, resting /sup 201/Tl myocardial scintigram, biplane left ventriculogram, and coronary angiograms. From the left ventriculogram, asynergy was quantified as percent abnormally contracting segment (% ACS), the percent of end-diastolic circumference which was either akinetic or dyskinetic. Using a computerized planimetry system, we expressed /sup 201/Tl perfusion defects as a percentage of total potential thallium uptake. Of 21 patients with ECG evidence of prior transmural infarction, a /sup 201/Tl defect was present in 20, and angiographic asynergy was present in all 21. The site of prior infarction by ECG agreed with the /sup 201/T1 defect location in 24 of 32 patients and with site of angiographic asynergy in 23 of 32 patients. Scintigraphic defects were present in only four of 10 patients with ACS less than or equal to 6%, but scintigraphic defects were found in 20 of 22 patients with ACS > 6%. Thallium defect size correlated marginally with angiographic left ventricular ejection fraction but correlated closely with angiographic % ACS. Thallium defect size was similar among patients with one-, two-, or three-vessel coronary artery disease (greater than or equal to 70% stenosis), but thallium defect size was larger in patients with electrocardiographic evidence of transmural infarction or pulmonary capillary wedge pressure > 12 mm Hg. Thus, resting /sup 201/T1 myocardial scintigraphy is useful in localizing and quantifying the extent of prior myocardial infarction, but is insensitive to small infarcts (ACS < 6%).

  17. Myocardial perfusion abnormalities in asymptomatic patients with systemic lupus erythematosus

    Energy Technology Data Exchange (ETDEWEB)

    Hosenpud, J.D.; Montanaro, A.; Hart, M.V.; Haines, J.E.; Specht, H.D.; Bennett, R.M.; Kloster, F.E.

    1984-08-01

    Accelerated coronary artery disease and myocardial infarction in young patients with systemic lupus erythematosus is well documented; however, the prevalence of coronary involvement is unknown. Accordingly, 26 patients with systemic lupus were selected irrespective of previous cardiac history to undergo exercise thallium-201 cardiac scintigraphy. Segmental perfusion abnormalities were present in 10 of the 26 studies (38.5 percent). Five patients had reversible defects suggesting ischemia, four patients had persistent defects consistent with scar, and one patient had both reversible and persistent defects in two areas. There was no correlation between positive thallium results and duration of disease, amount of corticosteroid treatment, major organ system involvement or age. Only a history of pericarditis appeared to be associated with positive thallium-201 results (p less than 0.05). It is concluded that segmental myocardial perfusion abnormalities are common in patients with systemic lupus erythematosus. Whether this reflects large-vessel coronary disease or small-vessel abnormalities remains to be determined.

  18. Usefulness of thallium-201 myocardial scintigraphy during hyperventilation and accelerated exercise test in patients with vasospastic angina and nearly normal coronary artery

    Energy Technology Data Exchange (ETDEWEB)

    Sueda, Shozo; Mineoi, Kazuaki; Kondou, Tadashi [Takanoko Hospital, Matsuyama, Ehime (Japan)] [and others

    1998-04-01

    The usefulness of thallium-201 ({sup 201}Tl) myocardial scintigraphy was studied in 109 patients with vasospastic angina who had nearly normal coronary arteries (degree of stenosis <50%). Coronary spasm was confirmed by pharmacologic agents in all 109 patients from January 1991 to June 1996. The appearance rate of visual redistribution on {sup 201}Tl myocardial scintigraphy was compared between four groups, 34 patients performing graded bicycle ergometer exercise starting at a work load of 50 W with increments of 25 W every 3 min (Ergo(3) group), 14 patients performing hyperventilation for 5 min (HV(5) group), 31 patients performing bicycle ergometer exercise with increments of 25 W every 1 min after 5 min hyperventilation (HV(5)+Ergo(1) group), and 30 patients at rest (Rest group). The value of the visual redistribution rate on {sup 201}Tl myocardial scintigrams in the HV(5)+Ergo(l) group (65%) was higher than that in the patients of other groups (Ergo(3) 41%, HV(5) 43%, Rest 33%). However, there were no significant differences between the four groups. Stress {sup 201}Tl imaging after hyperventilation and accelerated exercise is useful to disclose ischemic evidence in about two thirds of patients with vasospastic angina and nearly normal coronary arteries, whereas about 40% of patients had visual redistribution on {sup 201}Tl myocardial scintigrams by performing standard procedures. (author)

  19. A comparison of the clinical relevance of thallium201 and ...

    African Journals Online (AJOL)

    Thallium-201 is at present the radiotracer of choice for the clinical evaluation of myocardial blood flow. Although different technetium-99m-isonitrile agents have been synthesised recently, only 99mTc-melhoxyisobutyl-isonitrile (99mTc_MIBI) has proved to hold promise for clinical implementation. The myocardial distribution ...

  20. Simultaneous dual myocardial imaging with iodine-123-[beta]-methyl iodophenyl-pentadecanoic acid (BMIPP) and thallium-201 in patients with coronary heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Tawarahara, Kei; Kurata, Chinori; Taguchi, Takahisa; Aoshima, Shigeyuki; Okayama, Kenichi; Kobayashi, Akira; Yamazaki, Noboru; Kaneko, Masao (Hamamatsu Univ. School of Medicine, Shizuoka (Japan))

    1994-02-01

    To assess the clinical value of simultaneous dual myocardial imaging with iodine-123-[beta]-methyl-iodophenyl-pentadecanoic acid ([sup 123]I-BMIPP) and thallium-201 ([sup 201]TL), myocardial imaging was performed at rest and during execise in seven patients with coronary heart disease. When [sup 123]I-BMIPP and [sup 201]Tl images were compared, the initial exercise and resting images agreed 87% and 64%, respectively. In the initial resting images, the regional uptake of [sup 123]I-BMIPP was frequently less than that of [sup 201]Tl. The incidence of exercise-induced reversible defects by [sup 201]Tl in the Tl>BMIPP regions was significantly higher than that in the Tl=BMIPP regions (57% vs 4%, p<0.01) and the incidence of coronary narrowing of more than 90% in the Tl>BMIPP regions was also significantly higher than that in the Tl=BMIPP regions (91% vs 38%, p<0.01). In addition, this disparity (Tl>BMIPP) was found more frequently in regions with abnormal wall motion than in regions with normal wall motion (hypokinetic regions; 68%, severe hypokinetic or akinetic regions; 50%, vs normokinetic regions; 4%, p<0.01). In contrast, the uptake of [sup 123]I-BMIPP correlated closely with that of [sup 201]Tl in normal myocardium and the uptake of both [sup 123]I-BMIPP and [sup 201]Tl was severely reduced in myocardium with severe ischemia during exercise and prior infarction. These results indicate that dual myocardial imaging with [sup 123]I-BMIPP and [sup 201]Tl may provide a unique means of identifying patients with metabolically disturbed myocardium, such as hibernating and stunned myocardium. (author).

  1. Assessment of myocardial viability by dynamic tomographic iodine 123 iodophenylpentadecanoic acid imaging: comparison with rest-redistribution thallium 201 imaging.

    Science.gov (United States)

    Iskandrian, A S; Powers, J; Cave, V; Wasserleben, V; Cassell, D; Heo, J

    1995-01-01

    This study examined the ability of dynamic 123I-labeled iodophenylpentadecanoic acid (IPPA) imaging to detect myocardial viability in patients with left ventricular (LV) dysfunction caused by coronary artery disease. Serial 180-degree single-photon emission computed tomographic (SPECT) images (five sets, 8 minutes each) were obtained starting 4 minutes after injection of 2 to 6 mCi 123I at rest in 21 patients with LV dysfunction (ejection fraction [EF] 34% +/- 11%). The segmental uptake was compared with that of rest-redistribution 201Tl images (20 segments/study). The number of perfusion defects (reversible and fixed) was similar by IPPA and thallium (11 +/- 5 vs 10 +/- 5 segments/patient; difference not significant). There was agreement between IPPA and thallium for presence or absence (kappa = 0.78 +/- 0.03) and nature (reversible, mild fixed, or severe fixed) of perfusion defects (kappa = 0.54 +/- 0.04). However, there were more reversible IPPA defects than reversible thallium defects (7 +/- 4 vs 3 +/- 4 segments/patient; p = 0.001). In 14 patients the EF (by gated pool imaging) improved after coronary revascularization from 33% +/- 11% to 39% +/- 12% (p = 0.002). The number of reversible IPPA defects was greater in the seven patients who had improvement in EF than in the patients without such improvement (10 +/- 4 vs 5 +/- 4 segments/patient; p = 0.075). 123I-labeled IPPA SPECT imaging is a promising new technique for assessment of viability. Reversible defects predict recovery of LV dysfunction after coronary revascularization.

  2. Kinetic analysis of 18F-fluorodihydrorotenone as a deposited myocardial flow tracer: Comparison to thallium-201.

    Energy Technology Data Exchange (ETDEWEB)

    Marshall, Robert C.; Powers-Risius, Patricia; Reutter, Bryan W.; O' Neil, James P.; La Belle, Michael; Huesman, Ronald H.; VanBrocklin, Henry F.

    2004-03-01

    The goal of this investigation was to assess the accuracy of 18F-fluorodihydrorotenone (18F-FDHR) as a new deposited myocardial flow tracer and compare the results to those for 201Tl. Methods. The kinetics of these flow tracers were evaluated in 22 isolated, erythrocyte- and albumin-perfused rabbit hearts over a flow range encountered in patients. The two flow tracers plus a vascular reference tracer (131I-albumin) were introduced as a bolus through a port just above the aortic cannula. Myocardial extraction, retention, washout, and uptake parameters were computed from the venous outflow curves using the multiple indicator dilution technique and spectral analysis. Results. The mean initial extraction fractions of 18F-FDHR (0.85 +- 0.07) and 201Tl (0.87 +- 0.05) were not significantly different, although the initial extraction fraction for 18F-FDHR declined with flow (P < 0.0001), whereas the initial extraction fraction of 201Tl did not. Washout of 201Tl was faster (P < 0.001) and more affected by flow (P < 0.05) than 18F-FDHR washout. Except for initial extraction fraction, 18F-FDHR retention was greater (P < 0.001) and less affected by flow (P < 0.05) than 201Tl retention. Reflecting its superior retention, net uptake of 18F-FDHR was better correlated with flow than 201Tl uptake at both one and fifteen minutes after tracer introduction (P < 0.0001 for both comparisons). Conclusion. The superior correlation of 18F-FDHR uptake with flow indicates that it is a better flow tracer than 201Tl in the isolated rabbit heart. Compared to the other currently available positron-emitting flow tracers (82Rb, 13N-ammonia, and 15O-water), 18F-FDHR has the potential of providing excellent image resolution without the need for an on-site cyclotron.

  3. Evaluation of myocardial flow reserve using pharmacological stress thallium-201 single-photon emission computed tomography: is there a difference between total arterial off-pump coronary artery bypass grafting and conventional coronary artery bypass grafting?

    Science.gov (United States)

    Lee, Jae Won; Ryu, Sang Wan; Song, Hyun; Kim, Kyung Sun; Yang, Yu Jung; Moon, Dae Hyeuk

    2004-01-01

    The advantage of total arterial off-pump coronary bypass grafting (OPCAB) over conventional onpump coronary artery bypass grafting with 1 internal thoracic artery and veins (CCAB) in terms of myocardial flow reserve has not been studied. We studied these procedures using thallium- 201 perfusion single-photon emission computed tomography (Tl-201 perfusion SPECT). Between 1997 and 2001, 152 patients were recruited from our database (OPCAB, n = 100; CCAB, n = 52). All patients underwent pharmacological stress Tl-201 perfusion SPECT 3 to 12 months after bypass surgery. Myocardial perfusion was analyzed semiquantitatively with a 5-point scoring system in a 20-segment model (0, normal, to 4, absence of uptake). Summed stress (SSS), rest (SRS), and difference score (SDS) of the entire myocardium as well as average scores (ASS, ARS, ADS) of individual walls (anterior, septal, lateral, and inferior) were compared by Student t test as well as by repeated-measures analysis of variance with Bonferroni correction. The SSS, SRS, and SDS of OPCAB versus those of CCAB were 6.86 +/- 0.72 versus 7.17 +/- 0.92, 3.95 +/- 0.57 versus 3.75 +/- 0.73, and 2.91 +/- 0.47 versus 3.42 +/- 0.74 (P > .05). However, the lateral wall showed lower scores in OPCAB (ASS, 0.18 versus 0.41, P = .015; ARS, 0.12 versus 0.20, P = .168; ADS, 0.06 versus 0.21, P = .031). The septal wall had higher scores in OPCAB (ASS, 0.33 versus 0.12, P = .003; ARS, 0.18 versus 0.07, P = .037; ADS, 0.14 versus 0.04, P = .030). The anterior and inferior walls were not different between the 2 groups. OPCAB led to results similar to those of CCAB. The better results in the lateral wall have been the effect of grafting radial artery rather than vein. The similarity in myocardial reserve in the inferior wall between the 2 groups needs further study. There was no deleterious effect of off-pump as opposed to on-pump CAB.

  4. Myocardial imaging artifacts caused by mitral valve annulus calcification

    Energy Technology Data Exchange (ETDEWEB)

    Wagoner, L.E.; Movahed, A.; Reeves, W.C. (East Carolina Univ. School of Medicine, Greenville, NC (USA))

    1991-02-01

    Knowledge of imaging artifact of myocardial perfusion studies with thallium-201 is critical for improving the diagnostic accuracy of coronary artery disease. Three patients are described who underwent exercise or pharmacologic stress thallium-201 imaging studies and had a moderate, fixed myocardial perfusion defect (scar) involving the posterolateral and inferoposterior walls of the left ventricle. This was an imaging artifact caused by a heavily calcified mitral valve annulus.

  5. Iodine-123 phenylpentadecanoic acid and single photon emission computed tomography in identifying left ventricular regional metabolic abnormalities in patients with coronary heart disease: comparison with thallium-201 myocardial tomography.

    Science.gov (United States)

    Hansen, C L; Corbett, J R; Pippin, J J; Jansen, D E; Kulkarni, P V; Ugolini, V; Henderson, E; Akers, M; Buja, L M; Parkey, R W

    1988-07-01

    Iodine-123 phenylpentadecanoic acid (IPPA) is a synthetic long chain fatty acid with myocardial kinetics similar to palmitate. Two hypotheses were tested in this study. The first hypothesis was that IPPA imaging with single photon emission computed tomography (SPECT) is useful in the identification of patients with coronary artery disease. Fourteen normal volunteers (aged 27 +/- 2 years) and 33 patients (aged 54 +/- 11 years) with stable symptomatic coronary artery disease and at least one major coronary artery with luminal diameter narrowing greater than or equal to 70% were studied with symptom-limited maximal exercise testing. The IPPA (6 to 8 mCi) was injected 1 min before the termination of exercise, and tomographic imaging was performed beginning at 9 min and repeated at 40 min after the injection of IPPA. Nine of the normal volunteers and 13 of the patients had a second examination performed at rest on another day. Using the limits of normal as 2 SD from the normal mean values, 27 of the 33 patients with coronary artery disease demonstrated abnormalities in either the initial distribution or the clearance of IPPA, or both. Nineteen of the 33 patients had a maximal variation of activity distribution of greater than or equal to 25% on the 9 min IPPA images. Twenty-two of the 33 patients had a maximal variation in IPPA washout greater than 17% and 17 had a washout rate less than or equal to 2%. There was good agreement between the location of significant coronary artery stenoses and abnormalities in the initial distribution and clearance of IPPA. The second hypothesis tested was that IPPA imaging is as or more sensitive and, therefore, complementary to thallium-201 imaging in the identification of exercise-induced ischemia in patients. Twenty-five of the 33 patients underwent both thallium-201 and IPPA tomographic imaging after symptom-limited maximal exercise testing. The amount of exercise performed by each patient during both studies was similar. Twenty

  6. Exercise-induced U-wave changes in patients with coronary artery disease. Correlation with tomographic thallium-201 myocardial imaging

    Energy Technology Data Exchange (ETDEWEB)

    Miyakoda, Hiroyuki; Endo, Akihiro; Kato, Masahiko; Kato, Tatsuo; Omodani, Hiroki; Osaki, Shuichi; Kinugawa, Toru; Hoshio, Akira [Tottori Univ., Yonago (Japan). School of Medicine; Mashiba, Hiroto

    1996-09-01

    We studied the relation between exercise-induced U-wave changes and the site of a reversible defect in tomographic {sup 201}Tl myocardial imaging. Coronary artery disease and control groups consisted of 116 and 42 patients, respectively. In the anteroapical-ischemia group (n=37), the sensitivity of U-wave inversion in the anterior precordial leads for ischemia was 62% (23/37) and that of prominent U-waves without an increase in the height of the T-wave in the inferior limb leads was 57% (21/37). In this group, 18 patients (49%) met both criteria (18 =78%= of 23 patients with the former; 18 =86%= of 21 patients with the latter). In the posterior-ischemia group (n=59), the sensitivity of prominent U-waves with a decrease in the height of the T-wave in the anterior precordial leads for ischemia was 63% (37/59) and that of U-wave inversion in the inferior limb leads was 20% (12/59). In this group, 12 patients (20%) met both criteria (12 =32%= of 37 patients with the former; all 12 patients with the latter). The specificity of U-wave criteria was 100%. In the anteroapical and posterior-ischemia group (n=20), the sensitivity of U-wave criteria for anteroapical and posterior ischemia was 85% (17/20) and 40% (8/20), respectively. In conclusion, U-wave criteria are not only specific but also sensitive for myocardial ischemia determined by {sup 201}Tl imaging. (author)

  7. Comparison of I-123 IPPA and thallium-201 for the prediction of functional improvement after myocardial revascularization

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, C.L.; Van Decker, W.; Iskandrian, A.S. [Temple Univ. Hospital, Allegheny Univ. of the Health Sciences, Philadelphia, PA (United States)

    1998-12-31

    Sixteen patients in the phase I/II study of IPPA had RRT prior to MR. Patients were injected with 2-6 mCi of IPPA; sequential SPECT imaging was begun at 4 minutes. Radionuclide ventriculography was performed before and 8 weeks after MR. The ability of IPPA and RRT to identify patients with a 5% increase in EF after MR were compared using receiver operating characteristic (ROC) curve analysis. The IPPA images were analyzed using two techniques: The first method looked at the fraction of the myocardium (FM) demonstrating abnormal metabolism and the second at the FM demonstrating descreased initial perfusion and abnormal metabolism. RRT images were analyzed three different ways: Thresholded uptake on the initial images, thresholded uptake on the delayed images and relative improvement between the initial and delayed images. The parameters giving the highest ROC areas were identified for both IPPA and RRT and then compared. Five patients underwent PTCA and 11 underwent coronary artery bypass grafting. The mean EF increased from 36{+-}12% to 41{+-}14% after MR (p=0.012). The amount of myocardium (AM) showing intermediate metabolism (IM) of IPPA from 0.001 to 0.013 In counts/min was a strong predictor of FI after MR (area=0.92{+-}0.05). The AM that was hypoperfused and had IM (activity<90% of maximum uptake and metabolism from 0.002-0.013 In counts/min) was a stronger predictor (area=0.97 0.03). Using RRT, the best predictor was the AM with greater than 55% of maximal activity on the initial images (area=0.83{+-}0.10); the AM>45% of maximal activity on the delayed images was slightly lower (area=0.81{+-}0.10); improvement between the initial and delayed images was comparatively weak (0.56{+-}0.13). The difference between the areas between IPPA and RRT, however, was not statistically significant. (orig./MG) [Deutsch] Sechzehn Patienten der Phase-I/II-IPPA-Studie wurden einer RRT vor MR unterzogen. Es wurden 75-220 MBq IPPA injiziert und 4 min p.i. eine sequentielle SPECT

  8. Significance of exercise-induced ST segment depression in patients with myocardial infarction involving the left circumflex artery. Evaluation by exercise thallium-201 myocardial single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Koitabashi, Norimichi; Toyama, Takuji; Hoshizaki, Hiroshi [Gunma Prefectural Cardiovascular Center, Maebashi (Japan)] [and others

    2000-04-01

    The significance of exercise-induced ST segment depression in patients with left circumflex artery involvement was investigated by comparing exercise electrocardiography with exercise thallium-201 single photon emission computed tomography (Tl-SPECT) and the wall motion estimated by left ventriculography. Tl-SPECT and exercise electrocardiography were simultaneously performed in 51 patients with left circumflex artery involvement (angina pectoris 30, myocardial infarction 21). In patients with myocardial infarction, exercise-induced ST depression was frequently found in the V{sub 2}, V{sub 3} and V{sub 4} leads. In patients with angina pectoris, ST depression was frequently found in the II, III, aV{sub F}, V{sub 5} and V{sub 6} leads. There was no obvious difference in the leads of ST depression in patients with myocardial infarction with ischemia and without ischemia on Tl-SPECT images. In patients with myocardial infarction, the lateral wall motion of the infarcted area evaluated by left ventriculography was more significantly impaired in the patients with ST depression than without ST depression (p<0.01). Exercise-induced ST depression in the precordial leads possibly reflects wall motion abnormality rather than ischemia in the lateral infarcted myocardium. (author)

  9. Repeat thallium-201 SPECT in cerebral lymphoma.

    Science.gov (United States)

    Borggreve, F; Dierckx, R A; Crols, R; Mathijs, R; Appel, B; Vandevivere, J; Mariën, P; Martin, J J; De Deyn, P P

    1993-01-01

    The authors report on the contribution of Thallium-201 brain SPECT in the diagnosis and follow-up of a non-immunosuppressed patient, presenting with primary cerebral lymphoma. The tumoral process was at first not diagnosed on CT-scan, but Thallium-201 SPECT suggested a tumoral invasion. During corticosteroid treatment the tumor volume on CT-scan decreased, while on Thallium-201 SPECT there was an enhancement of the accumulation and an increasing tumor to non-tumor ratio. These scintigraphical findings more closely reflected the clinical course and the postmortem results.

  10. Thallium-201 scintigraphy in unstable angina pectoris

    Energy Technology Data Exchange (ETDEWEB)

    Wackers, F.J.T.; Lie, K.I.; Liem, K.L.; Sokole, E.B.; Samson, G.; Van Der Schoot, J.B.; Durrer, D.

    1978-04-01

    Thallium-201 scintigraphy was performed during the pain free period in 98 patients with unstable angina. Scintiscans were positive in 39 patients, questionable in 27 patients and normal in 32 patients. Eighty-one patients responded favorably to treatment (group I). Seventeen patients had complicated courses (group II) and despite maximal treatment with propranolol either developed infarction (six patients) or continued to have angina necessitating coronary surgery (11 patients). In group I during the pain free period 26 of 81 patients had positive thallium-201 scans, whereas 20 patients had an abnormal ECG at that time; during angina 18 patients had transient ECG changes. In group II during the pain free period 13 of 17 patients had positive scans, whereas two patients had abnormal ECG at that time; during angina 12 patients showed transient ECG changes. The sensitivity to recognize group II was 76% for thallium-201 scintigraphy, 11% for ECG during the pain free period; 70% for ECG during angina; 94% for the combination of either positive scans or abnormal ECG. Thus, positive thallium-201 scans occur in patients with unstable angina, positive scans can be obtained during the pain free period, thallium-201 scans are more frequently positive in patients with complicated course.

  11. Biokinetics of radiolabeled Iodophenylpentadecanoic acid (I-123-IPPA) and thallium-201 in a rabbit model of chronic myocardial infarction measured using a series of thermoluminescent dosimeters

    Science.gov (United States)

    Medich, David Christopher

    1997-09-01

    The biokinetics of Iodophenylpentadecanoic acid (123I-IPPA) during a chronic period of myocardial infarction were determined and compared to 201Tl. IPPA was assessed as a perfusion and metabolic tracer in the scintigraphic diagnosis of coronary artery disease. The myocardial clearance kinetics were measured by placing a series of thermoluminescent dosimeters (TLDs) on normal and infarcted tissue to measure the local myocardial activity content over time. The arterial blood pool activity was fit to a bi-exponential function for 201Tl and a tri-exponential function for 123I-IPPA to estimate the left ventricle contribution to TLD response. At equilibrium, the blood pool contribution was estimated experimentally to be less than 5% of the total TLD response. The method was unable to resolve the initial uptake of the imaging agent due in part to the 2 minute TLD response integration time and in part to the 30 second lag time for the first TLD placement. A noticeable disparity was observed between the tracer concentrations of IPPA in normal and ischemic tissue of approximately 2:1. The fitting parameters (representing the biokinetic eigenvalue rate constants) were related to the fundamental rate constants of a recycling biokinetic model. The myocardial IPPA content within normal tissue was elevated after approximately 130 minutes post injection. This phenomenon was observed in all but one (950215) of the IPPA TLD kinetics curves.

  12. Clinical features and applications of thallium-201. With reference to scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Tadashige

    1988-12-01

    Thallium-201 is not only used widely in myocardial imaging but also has a great potential in other various nuclear medicine imaging studies. This paper presents clinical features and applications of thallium-201, focusing on clinical trials with thallium-201 at the Shinshu University School of Medicine. Thallium-201 myocardial scintigraphy offers information on (1) ventricular position and morphology, (2) hypertrophy or dilatation of the left ventricle, (3) hypertrophy or dilatation of the right ventricle, (4) site and extent of myocardial ischemia and infarct, (5) myocardial blood flow, (6) pulmonary congestion or interstitial pulmonary edema, and (7) pericardial effusion. It can be used in the following evaluation or diagnosis: (1) acute or old myocardial infarction, (2) angina pectoris, (3) treatment strategy or prognosis of ischemic heart disease, (4) treatment strategy or observation of bypass graft or drug therapy, (5) hypertrophic or dilated idiopathic cardiomyopathy, (6) myocardial lesions induced by sarcoidosis, collagen disease, and neuro-muscular disease, (7) ventricular hypertrophy and pulmonary edema, and (9) pericarditis, pericardial effusion, and systolic pericarditis associated with underlying disease. The significance of tumor, liver, bone marrow scintigraphies is also referred to. (Namekawa, K) 69 refs.

  13. Noninvasive quantification of myocardial perfusion heterogeneity by Markovian analysis in SPECT nuclear imaging; Quantification non invasive de l'heterogeneite de la perfusion du myocarde par analyse markovienne en imageries nucleaire SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Pons, G.

    2011-04-28

    Cardiovascular diseases are the leading cause of mortality worldwide, and third of these deaths are caused by coronary artery disease and rupture of vulnerable atherosclerotic plaques. The heterogeneous alteration of the coronary microcirculation is an early phenomenon associated with many cardiovascular risk factors that can strongly predict the subsequent development of coronary artery disease, and lead to the appearance of myocardial perfusion heterogeneity. Nuclear medicine allows the study of myocardial perfusion in clinical routine through scintigraphic scans performed after injection of a radioactive tracer of coronary blood flow. Analysis of scintigraphic perfusion images currently allows the detection of myocardial ischemia, but the ability of the technique to measure the perfusion heterogeneity in apparently normally perfused areas is unknown. The first part of this thesis focuses on a retrospective clinical study to determine the feasibility of myocardial perfusion heterogeneity quantification measured by Thallium-201 single photon emission computed tomography (SPECT) in diabetic patients compared with healthy subjects. The clinical study has demonstrated the ability of routine thallium-201 SPECT imaging to quantify greater myocardial perfusion heterogeneity in diabetic patients compared with normal subjects. The second part of this thesis tests the hypothesis that the myocardial perfusion heterogeneity could be quantified in small animal SPECT imaging by Thallium-201 and/or Technetium-99m-MIBI in an experimental study using two animal models of diabetes, and is correlated with histological changes. The lack of difference in myocardial perfusion heterogeneity between control and diabetic animals suggests that animal models are poorly suited, or that the technology currently available does not seem satisfactory to obtain similar results as the clinical study. (author)

  14. Detection of human collateral circulation by vasodilation-thallium-201 tomography

    Energy Technology Data Exchange (ETDEWEB)

    Nienaber, C.A.; Salge, D.; Spielmann, R.P.; Montz, R.; Bleifeld, W. (University Hospital Eppendorf, Hamburg (Germany, F.R.))

    1990-04-15

    Coronary arteriolar vasodilation may provoke redistribution of flow to collateral-dependent jeopardized myocardium. To assess the physiologic significance of collaterals, 80 consecutive post-infarction patients (age 58 +/- 8 years) underwent vasodilation-redistribution thallium-201 tomographic imaging after administration of 0.56 mg of intravenous dipyridamole/kg body weight. Circumferential profile analysis of thallium-201 uptake and redistribution in representative left ventricular tomograms provided quantitative assessment of transient and fixed defects and separation between periinfarctional and distant inducible hypoperfusion. Tomographic perfusion data were correlated to wall motion and collateral circulation between distinct anatomic perfusion territories. Patients were grouped according to presence (59%) or absence (41%) of angiographically visible collateral channels to jeopardized myocardium. In the presence of collaterals, distant reversible defects were larger than in absence of collaterals (p less than 0.05); the extent of combined periinfarctional and distant redistribution was also larger in collateralized patients (p less than 0.025), whereas the size of the persistent perfusion defect was similar in both groups. By prospective analysis the tomographic perfusion pattern of combined periinfarctional and distant redistribution revealed a sensitivity of 85% and a specificity of 78% for the detection of significant collateral circulation in this group of patients. Thus, using the exhausted flow reserve as a diagnostic tool, vasodilation-thallium-201 tomography has the potential to identify and quantitate collateralized myocardium in post-infarction patients and may guide diagnostic and therapeutic decision-making.

  15. Functional Significance of Angiographic Collaterals in Patients with Totally Occluded Right Coronary Artery: Intracoronary Thallium-201 Scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Yun; Lee, Jong Doo; Cho, Seung Yun; Shim, Won Heum; Ha, Jong Won; Kim, Han Soo; Kwon, Hyuk Moon; Jang, Yang Soo; Chung, Nam Sik; Kim, Sung Soon [Yonsei University College of Medicine, Seoul (Korea, Republic of); Park, Chang Yun; Kim, Young Soo [Inje University College of Medicine, Seoul (Korea, Republic of)

    1993-07-15

    To compare the myocardial viability in patients suffering from total occlusion of the right coronary artery (RCA) with the angiographic collaterals, intracoronary injection of Thallium-201 (T1-201) was done to 14 coronary artery disease (CAD) patients (pts) with total occlusion of RCA and into four normal subjects for control. All 14 CAD pts had Grade 2 or 3 collateral circulations. There were 14 male and 4 females, and their ages ranged from 31 to 70 years. In nine pts, T1-201 was injected into left main coronary artery (LCA) (300 approx 350 mu Ci) to evaluate the myocardial viability of RCA territory through collateral circulations. The remaining five pts received T1-201 into RCA (200-250 mu Ci) because two had intraarterial bridging collaterals and three had previous successful PTCA. Planar and SPECT myocardial perfusion images were obtained 30 minutes, and four to five hours after T1-201 reinjection. Intravenous T1-201 reinjection (six pts) or {sup 99m}Tc-MIBI (two pts) were also performed in eight CAD pts. Intracoronary myocardial perfusion images were compared with intravenous T1-201(IV T1-201) images, EGG, and ventriculography. Intracoronary TI-201 images proved to be superior to that of IV T1-201 due to better myocardial to background uptake ratio and more effective in the detection of viable tissue. We also found that perfusion defects were smaller on intracoronary T1-201 images than those on the IV T1-201. All of the 14 CAD pts had either mostly viable myocardium (seven pts) or large area of T1-201 perfusion (seven pts) in RCA territory, however ventriculographic wall motion and ECG did not correlate well with intracoronary myocardial perfusion images. In conclusion, total RCA occlusion patients with well developed collateral circulation had large area of viable myocardial in the corresponding territory.

  16. Combined thallium-201 and dynamic iodine-123 iodophenylpentadecanoic acid single-photon emission computed tomography in patients after acute myocardial infarction with effective reperfusion.

    Science.gov (United States)

    Richter, W S; Beckmann, S; Cordes, M; Schuppenhauer, T; Schartl, M; Munz, D L

    2000-12-01

    Considerable derangements of energy metabolism are to be expected during ischemia and reperfusion. In ischemic myocardium, the oxidative degradation of carbohydrates is shifted toward the anaerobic production of lactate and the oxidation of fatty acids is suppressed. The aim of this study was to examine the uptake and metabolism of iodine-123 (123I) iodophenylpentadecanoic acid (IPPA) in stunned myocardium. In 15 patients, SPECT with 201Tl and 123I IPPA as well as echocardiography with low-dose dobutamine stimulation were performed 12 +/- 5 days after myocardial infarction with reperfusion. Follow-up echocardiography was carried out 24 +/- 8 days later for documentation of functional improvement. Uptake of 201Tl and 123I IPPA were obtained in five left ventricular segments, and dynamic SPECT imaging was used for calculation of the fast and the slow components of the biexponential myocardial 123I IPPA clearance. Wall motion improved in 14 of 26 dysfunctional segments (54%). Stunned segments were characterized by a reduced 123I IPPA extraction, a shorter half-life of the fast, and a longer half-life of the slow clearance component. All parameters of the combined 201Tl/123I IPPA study predicted functional recovery with similar accuracies (area under the receiver operator characteristic curves between 0.68 and 0.76; p = NS). Analysis of 201Tl uptake alone could not predict functional recovery in this study. Stunned myocardium is characterized by a disturbance of fatty acid metabolism. For prediction of functional improvement, 123I IPPA imaging added significant diagnostic information.

  17. Thallium-201 single photon emission computed tomography (SPECT) in patients with Duchenne's progressive muscular dystrophy. A histopathologic correlation study

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, Toru; Yanagisawa, Atsuo; Sakata, Konomi; Shimoyama, Katsuya; Yoshino, Hideaki; Ishikawa, Kyozo [Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine; Sakata, Hitomi; Ishihara, Tadayuki

    2001-02-01

    The pathomorphologic mechanism responsible for abnormal perfusion imaging during thallium-201 myocardial single photon emission computed tomography ({sup 201}Tl-SPECT) in patients with Duchenne's progressive muscular dystrophy (DMD) was investigated. Hearts from 7 patients with DMD were evaluated histopathologically at autopsy and the results correlated with findings on initial and delayed resting {sup 201}Tl-SPECT images. The location of segments with perfusion defects correlated with the histopathologically abnormal segments in the hearts. Both the extent and degree of myocardial fibrosis were severe, especially in the posterolateral segment of the left ventricle. Severe transmural fibrosis and severe fatty infiltration were common in segments with perfusion defects. In areas of redistribution, the degree of fibrosis appeared to be greater than in areas of normal perfusion; and intermuscular edema was prominent. Thus, the degree and extent of perfusion defects detected by {sup 201}Tl-SPECT were compatible with the histopathology. The presence of the redistribution phenomenon may indicate ongoing fibrosis. Initial and delayed resting {sup 201}Tl-SPECT images can predict the site and progress of myocardial degeneration in patients with DMD. (author)

  18. Low-dose dobutamine myocardial perfusion scintigraphy in the identification of viable myocardium

    Energy Technology Data Exchange (ETDEWEB)

    Moraes, Renata Freire de [Instituto Hermes Pardini, Belo Horizonte, MG (Brazil). Dept. of Molecular Imaging and Diagnosis. Div. of Nuclear Medicine; Meneghetti, Jose Claudio [Instituto do Coracao (InCor-HC/FM/USP), Sao Paulo, SP (Brazil). Unit of Nuclear Medicine and Molecular Imaging; Barroso, Adelanir Antonio, E-mail: renatafreire@yahoo.com.b [Nuclear Medcenter, Belo Horizonte, MG (Brazil)

    2010-09-15

    Objective: to evaluate the increase in specificity of dual isotope myocardial perfusion gated SPECT ({sup 99m}Tcsestamibi/thallium-201), a highly sensitive method to detect viable myocardium, with addition of data on contractile reserve simultaneously acquired by low-dose dobutamine gated SPECT, similarly to echocardiography. Materials and methods: a total of 260 myocardial segments were assessed in 13 patients with myocardial infarction referred for investigation of myocardial viability before undergoing revascularization. Cellular integrity and contractile reserve were evaluated by dual isotope perfusion myocardial gated SPECT with thallium rest and redistribution images and post-stress {sup 99m}Tc-sestamibi gated-SPECT images under basal conditions and with low-dose dobutamine. The improvement in the contractile performance detected by post-revascularization {sup 99m}Tc-sestamibi gated SPECT was the parameter considered for determining myocardial viability. For the purpose of results analysis, the functional parameters of the myocardial segments were quantified at the different phases of the study and stratified according to their viability for a later post-revascularization functional comparison. Results: in the statistical analysis, systolic wall thickening demonstrated to be a relevant parameter in the evaluation of myocardial contractile reserve by this method, with a tendency of improvement in the specificity (84%), demonstrating higher values than those observed in the literature. Conclusion: this method tends to present an effective contribution in the assessment of myocardial viability. (author)

  19. Measuring myocardial perfusion

    DEFF Research Database (Denmark)

    Qayyum, A A; Kastrup, J

    2015-01-01

    Recently, focus has changed from anatomical assessment of coronary arteries towards functional testing to evaluate the effect of stenosis on the myocardium before intervention. Besides positron-emission tomography (PET), cardiac MRI (CMR), and cardiac CT are able to measure myocardial perfusion......-known and is used in routine clinical practice. However, PET uses radioactive tracers and has a lower spatial resolution compared to CMR and CT. CMR and CT are emerging techniques in the field of myocardial perfusion imaging. CMR uses magnetic resonance to obtain images, whereas CT uses x-rays during first...

  20. Dual myocardial single photon emission computed tomography (SPECT) using thallium-201 and I-123-{beta}-methyl-i-pentadecanoic acid in patients with Duchenne's progressive muscular dystrophy

    Energy Technology Data Exchange (ETDEWEB)

    Shimoyama, Katsuya [Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine

    1999-10-01

    Dual single photon emission computed tomography (SPECT) was performed in 31 patients with Duchenne's progressive muscular dystrophy (DMD) using {sup 123}I-{beta}-methyl pentadecanoic acid (BMIPP) for myocardial fatty acid metabolism and {sup 201}thallium (Tl)-chloride for myocardial perfusion. The left ventricle was divided into 9 segments, and accumulation of the radiotracers was assessed visually for each segment to calculate defect score for each tracer. There was some degree of decrease in myocardial accumulation of both tracers in all DMD patients. Reduced accumulation was most common at the apex (BMIPP: 67%, Tl: 63%), followed by the posterior wall, lateral wall, and anterior wall. On the other hand, reduced accumulation was less common at the septum. BMIPP showed a higher accumulation than Tl in all segments but the septum. When BMIPP defect score was larger than Tl defect score, BMIPP defect score tended to increase during 4 years follow-up (p<0.042). However, when Tl defect score was larger than BMIPP defect score, an increase in Tl defect score was slight. A significant negative correlation was found between the sum of the BMIPP and Tl defect scores and the left ventricular ejection fraction (LVEF) (r=0.66, p<0.0001). According to the histo-pathological study of two autopsied hearts, severe myocardial fibrosis was seen in segments with fixed perfusion defect. In addition, the mismatched segments of BMIPP defect score > Tl defect score revealed a slight fibrosis or normal myocardium. It can be concluded that the dual SPECT myocardial scintigraphy using BMIPP and Tl provides accurate information about disease progression of the heart in patients with DMD by detecting abnormalities of the myocardial metabolism of each substance, thereby enabling the assessment of left ventricular function. (author)

  1. Comparison of thallium deposition with segmental perfusion in pigs with chronic hibernating myocardium.

    Science.gov (United States)

    Baldwa, Sunil; Rana, Muzamil; Canty, John M; Fallavollita, James A

    2008-12-01

    Viable, chronically dysfunctional myocardium with reduced resting flow (or hibernating myocardium) is an important prognostic factor in ischemic heart disease. Although thallium-201 imaging is frequently used to assess myocardial viability in patients with ischemic cardiomyopathy, there are limited data regarding its deposition in hibernating myocardium, and this data suggest that thallium retention may be supernormal compared with control myocardium. Accordingly, pigs (n=7) were chronically instrumented with a 1.5 mm Delrin stenosis on the proximal left anterior descending coronary artery (LAD) to produce hibernating myocardium. Four months later, severe anteroapical hypokinesis was documented with contrast ventriculography (wall motion score, 0.7+/-0.8; normal=3), and microsphere measurements confirmed reduced resting flow (LAD subendocardium, 0.78+/-0.34 vs. 0.96+/-0.24 ml.min(-1).g(-1) in remote; P<0.001). Absolute deposition of thallium-201 and insulin-stimulated [18F]-2 fluoro-2-deoxyglucose (FDG) were assessed over 1 h and compared with resting flow (n=704 samples). Thallium-201 deposition was only weakly correlated with perfusion (r2=0.20; P<0.001) and was more homogeneously distributed (relative dispersion, 0.12+/-0.03 vs. 0.29+/-0.10 for microsphere flow; P<0.01). Thus after 1 h relative thallium-201 (subendocardium LAD/remote, 0.96+/-0.16) overestimated relative perfusion (0.78+/-0.32; P<0.0001) and underestimated the relative reduction in flow. Viability was confirmed by both histology and preserved FDG uptake. We conclude that under resting conditions, thallium-201 redistribution in hibernating myocardium is nearly complete within 1 h, with similar deposition to remote myocardium despite regional differences in flow. These data suggest that in this time frame thallium-201 deposition may not discriminate hibernating myocardium from dysfunction myocardium with normal resting flow. Since hibernating myocardium has been associated with a worse prognosis

  2. Myocardial perfusion modeling using MRI

    DEFF Research Database (Denmark)

    Larsson, H B; Fritz-Hansen, T; Rostrup, Egill

    1996-01-01

    In the present study, it is shown that it is possible to quantify myocardial perfusion using magnetic resonance imaging in combination with gadolinium diethylenetriaminopentaacetic acid (Gd-DTPA). Previously, a simple model and method for measuring myocardial perfusion using an inversion recovery...

  3. Myocardial perfusion modeling using MRI

    DEFF Research Database (Denmark)

    Larsson, H B; Fritz-Hansen, T; Rostrup, Egill

    1996-01-01

    In the present study, it is shown that it is possible to quantify myocardial perfusion using magnetic resonance imaging in combination with gadolinium diethylenetriaminopentaacetic acid (Gd-DTPA). Previously, a simple model and method for measuring myocardial perfusion using an inversion recovery...... in the anterior myocardial wall were (mean +/- SD) Ki = 54 +/- 10 ml/100 g/min, lambda = 30 +/- 3 ml/100 g, Vb = 9 +/- 2 ml/100 g, delta T = 3.2 +/- 1.1 s. These results are in good agreement with similar results obtained by other methods....

  4. Myocardial perfusion after marathon running.

    Science.gov (United States)

    Kalliokoski, Kari K; Laaksonen, Marko S; Luotolahti, Matti; Laine, Hanna; Takala, Teemu O; Nuutila, Pirjo; Knuuti, Juhani

    2004-08-01

    We investigated the effects of acute prolonged exercise (marathon running) on cardiac function and myocardial perfusion. Cardiac dimensions and function were measured in seven endurance-trained men using echocardiography before and repeatedly after marathon (42.2 km) running (at 10 min, 150 min, and 20 h). Myocardial perfusion and perfusion resistance were measured using positron emission tomography and 15O-H2O before and 85-115 min after running. Echocardiographic indices showed only mild and clinically non-significant changes in cardiac function after running. Rate-pressure-corrected basal myocardial perfusion (0.89+/-0.13 vs. 1.20+/-0.32 mL min(-1) g(-1), P=0.04) was increased after running. Also, adenosine-stimulated perfusion tended to be higher (3.67+/-0.81 vs. 4.47+/-0.52 mL min(-1) g(-1), P=0.12) and perfusion resistance during adenosine stimulation was significantly lower after running (26+/-6 vs. 18+/-3 mmHg min g mL(-1), P=0.03). Plasma free fatty acid (FFA) concentration was significantly increased after running. These results show that marathon running does not cause marked changes in cardiac function in healthy men. Basal perfusion was increased after exercise, probably reflecting changes in fuel preferences to increased use of FFAs. Strenuous exercise also seems to enhance coronary reactivity, which could thereby serve as a protective mechanism to vascular events after exercise.

  5. Dynamic CT myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Caruso, Damiano [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiological Sciences, Oncological and Pathological Sciences, University of Rome “Sapienza”, Latina (Italy); Eid, Marwen [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC (United States); Jin, Kwang Nam [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiology, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Seoul (Korea, Republic of); Varga-Szemes, Akos [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Tesche, Christian [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Cardiology and Intensive Care Medicine, Heart Center Munich-Bogenhausen, Munich (Germany); Mangold, Stefanie [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, Tuebingen (Germany); and others

    2016-10-15

    Highlights: • CT myocardial perfusion provides functional assessment of the myocardium. • CCTA is limited in determining the hemodynamic significance of coronary stenosis. • CT-MPI can accurately detect hemodynamically significant coronary artery stenosis. - Abstract: Non-invasive cardiac imaging has rapidly evolved during the last decade due to advancements in CT based technologies. Coronary CT angiography has been shown to reliably assess coronary anatomy and detect high risk coronary artery disease. However, this technique is limited to anatomical assessment, thus non-invasive techniques for functional assessment of the heart are necessary. CT myocardial perfusion is a new CT based technique that provides functional assessment of the myocardium and allows for a comprehensive assessment of coronary artery disease with a single modality when combined with CTA. This review aims to discuss dynamic CT myocardial perfusion as a new technique in the assessment of CAD.

  6. Radio-adaptive Response in Myocardial Perfusion Imaging Induced by Technetium-99m.

    Science.gov (United States)

    Shirazi, Mohammad Mehdi; Shabestani-Monfared, Ali; Shahidi, Maryam; Amiri, Mehrangiz; Abedi, Seyed Mohammad; Borzoueisileh, Sajad; Gorji, Kourosh Ebrahim Nejad

    2017-01-01

    Low dose radiation will induce adaptation and following exposure to an adaptive dose, the cells are more resistance to following challenging doses. This phenomenon is known as radio-adaptive response. The aim of this study was to investigate the percentage of apoptotic cells in the peripheral blood samples of the patients which undergo myocardial perfusion imaging (MPI) with technetium-99m (Tc-99m) before thallium scan to assess the induction of radio-adaptive response. In this study, 97 samples from 74 patients, referred to nuclear medicine center of Mazandaran Heart Hospital for MPI, which had no history of diagnostic, therapeutic, occupational, and radioactive exposures during past 2 years, were provided. The participants were classified into four groups including control, patients which were scanned solely with technetium, the patients which examined by thallium and the last group were the patients that examined by technetium followed by thallium. Then 2 ml Peripheral blood samples were obtained, and after 24 h incubating, the samples were studied by neutral comet assay. Statistical analysis was carried out using Student's t-test along with one-way analysis of variance. The mean percentage of apoptotic cells in the exposed groups were higher than the control. Furthermore, among exposed groups, the apoptotic cells in thallium group were more than others and this index was significantly lower in the group which was undergone technetium administration before thallium scan. These findings suggest that exposure to Tc-99m could induce a radio-adaptive response against the exposure of thallium-201.

  7. Specificity of the stress electrocardiogram during adenosine myocardial perfusion imaging in patients taking digoxin.

    Science.gov (United States)

    Hart, C Y; Miller, T D; Hodge, D O; Gibbons, R J

    2000-12-01

    In patients taking digoxin, the exercise electrocardiogram has a lower specificity for detecting coronary artery disease. However, the effect of digoxin on adenosine-induced ST-segment depression is unknown. The purpose of this study was to evaluate the specificity of the electrocardiogram during adenosine myocardial perfusion imaging in patients taking digoxin. Between May 1991 and September 1997, patients (n = 99) taking digoxin who underwent adenosine stress imaging with thallium-201 or technetium-99m sestamibi and coronary angiography within 3 months were retrospectively identified. Exclusion criteria included prior myocardial infarction, coronary artery angioplasty or bypass surgery, left bundle branch block, paced ventricular rhythm, or significant valvular disease. Twelve-lead electrocardiograms were visually interpreted at baseline, during adenosine infusion, and during the recovery period. The stress electrocardiogram was considered positive if there was > or =1 mm additional horizontal or downsloping ST-segment depression or elevation 0.08 seconds after the J-point compared with the baseline tracing. ST-segment depression and/or elevation occurred in 24 of 99 patients. There were only 2 false-positive stress electrocardiograms, yielding a specificity of 87% and positive predictive value of 92%. All 8 patients with > or =2 mm ST segment depression had multivessel disease by coronary angiography. ST-segment depression or elevation during adenosine myocardial perfusion imaging in patients taking digoxin is highly specific for coronary artery disease. Marked (> or =2 mm) ST-segment depression and/or ST-segment elevation is associated with a high likelihood of multivessel disease.

  8. Dosimetry in myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Toledo, Janine M.; Trindade, Bruno; Ribeiro, Tarcisio P.C. [Universidade Federal de Minas Gerais (DEN/UFMG), Belo Horizonte (Brazil). Dept. de Engenharia Nuclear. Programa de Pos-Graduacao em Ciencias e Tecnicas Nucleares

    2011-07-01

    This paper conducts a dosimetric investigation on the myocardial perfusion image protocol, together with a literature reviewing, motivated by the significant statistic increasing on mortality, morbidity and disability associated with cardiovascular disease, surpassing infectious diseases. Nuclear Cardiology plays a role n the diagnostic functional evaluation of the heart and in the prognostic of patients with suspected or known cardiac ischemia. In the context of unstable myocardial ischemic syndrome, myocardial perfusion scintigraphy is a non-invasive procedure performed by administering a radiopharmaceutical targeted to the heart. As tool for this study are that the images obtained by thoracic angiotomography and abdominal aorta as a anatomic and functional information for model reproduction in SISCODES - System of Codes for Absorbed Dose Calculations based on Stochastic Methods. Data were manipulated in order to create a voxel computational model of the heart to be running in MCNP - Monte Carlo Neutron Particle Code. . It was assumed a homogeneous distribution of Tl-201 in cardiac muscle. Simulations of the transport of particles through the voxel and the interaction with the heart tissue were performed. As a result, the isodose curves in the heart model are displayed as well as the dose versus volume histogram of the heart muscle. We conclude that the present computational tools can generate doses distributed in myocardial perfusion. (author)

  9. SU-C-201-04: Quantification of Perfusion Heterogeneity Based On Texture Analysis for Fully Automatic Detection of Ischemic Deficits From Myocardial Perfusion Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Fang, Y [National Cheng Kung University, Tainan, Taiwan (China); Huang, H [Chang Gung University, Taoyuan, Taiwan (China); Su, T [Chang Gung Memorial Hospital, Taoyuan, Taiwan (China)

    2015-06-15

    Purpose: Texture-based quantification of image heterogeneity has been a popular topic for imaging studies in recent years. As previous studies mainly focus on oncological applications, we report our recent efforts of applying such techniques on cardiac perfusion imaging. A fully automated procedure has been developed to perform texture analysis for measuring the image heterogeneity. Clinical data were used to evaluate the preliminary performance of such methods. Methods: Myocardial perfusion images of Thallium-201 scans were collected from 293 patients with suspected coronary artery disease. Each subject underwent a Tl-201 scan and a percutaneous coronary intervention (PCI) within three months. The PCI Result was used as the gold standard of coronary ischemia of more than 70% stenosis. Each Tl-201 scan was spatially normalized to an image template for fully automatic segmentation of the LV. The segmented voxel intensities were then carried into the texture analysis with our open-source software Chang Gung Image Texture Analysis toolbox (CGITA). To evaluate the clinical performance of the image heterogeneity for detecting the coronary stenosis, receiver operating characteristic (ROC) analysis was used to compute the overall accuracy, sensitivity and specificity as well as the area under curve (AUC). Those indices were compared to those obtained from the commercially available semi-automatic software QPS. Results: With the fully automatic procedure to quantify heterogeneity from Tl-201 scans, we were able to achieve a good discrimination with good accuracy (74%), sensitivity (73%), specificity (77%) and AUC of 0.82. Such performance is similar to those obtained from the semi-automatic QPS software that gives a sensitivity of 71% and specificity of 77%. Conclusion: Based on fully automatic procedures of data processing, our preliminary data indicate that the image heterogeneity of myocardial perfusion imaging can provide useful information for automatic determination

  10. Evaluation of muscular lesions in connective tissue diseases: thallium 201 muscular scans

    Energy Technology Data Exchange (ETDEWEB)

    Guillet, G.; Guillet, J.; Sanciaume, C.; Maleville, J.; Geniaux, M.; Morin, P.

    1988-04-01

    We performed thallium 201 muscle scans to assess muscular involvement in 40 patients with different connective tissue diseases (7 with dermatomyositis, 7 with systemic lupus erythematosus, 12 with progressive systemic scleroderma, 2 with calcinosis, Raynaud's phenomenon, esophageal involvement, sclerodactyly, and telangiectasia (CREST) syndrome, 3 with monomelic scleroderma, 6 with morphea, and 3 with Raynaud's disease). Only 12 of these patients complained of fatigability and/or myalgia. Electromyography was performed and serum levels of muscle enzymes were measured in all patients. Comparison of thallium 201 exercise recording with the other tests revealed that scan sensitivity is greater than electromyographic and serum muscle enzymes levels. Thallium 201 scans showed abnormal findings in 32 patients and revealed subclinical lesions in 18 patients, while electromyography findings were abnormal in 25 of these 32 patients. Serum enzyme levels were raised in only 8 patients. Thallium 201 scanning proved to be a useful guide for modifying therapy when laboratory data were conflicting. It was useful to evaluate treatment efficacy. Because our data indicate a 100% positive predictive value, we believe that thallium 201 scanning should be advised for severe systemic connective tissue diseases with discordant test results.

  11. Regadenoson for myocardial perfusion scintigraphy.

    Science.gov (United States)

    Reyes, Eliana; Pennell, Dudley J

    2010-09-01

    Stress myocardial perfusion scintigraphy (MPS) plays a major role in the detection of obstructive coronary artery disease and provides valuable diagnostic and prognostic information to guide clinical decision-making with regard to medical therapy and coronary revascularisation. Current stress techniques for MPS are effective but their use may be limited by reduced tolerability, contraindications and untoward side effects. The recently developed selective adenosine A2A receptor agonists have the potential for improving stress tolerability, hence expanding the indications for functional imaging in the assessment of coronary artery disease. This article reviews the basic principles underlying activation of coronary arteriolar adenosine A2A receptors. It describes the benefits and limitations of current vasodilator stress agents and highlights the effectiveness, side effect profile and tolerability of regadenoson, the only selective adenosine A2A receptor agonist available at present for clinical use. The reader will gain an understanding of the pharmacokinetics and mechanism of action of regadenoson for the assessment of coronary artery disease when combined with myocardial perfusion imaging. The reader will also become aware of the available evidence on the clinical usefulness of regadenoson MPS and its future applications. Selective activation of coronary arteriolar adenosine A2A receptors by regadenoson provides an effective modality of stress for the detection of inducible perfusion abnormality in patients with known or suspected coronary disease. The effectiveness of regadenoson is similar to that of adenosine, but test tolerability is improved with regadenoson. The use of this agent simplifies stress testing and has the potential for expanding the applications of functional imaging to patient populations unsuitable for conventional vasodilator stress with adenosine or dipyridamole.

  12. Effects of adenosine and a selective A2A adenosine receptor agonist on hemodynamic and thallium-201 and technetium-99m-sestaMIBI biodistribution and kinetics.

    Science.gov (United States)

    Mekkaoui, Choukri; Jadbabaie, Farid; Dione, Donald P; Meoli, David F; Purushothaman, Kailasnath; Belardinelli, Luiz; Sinusas, Albert J

    2009-10-01

    The purpose of this study was to compare a selective A(2A) adenosine receptor agonist (regadenoson) with adenosine in clinically relevant canine models with regard to effects on hemodynamics and thallium-201 ((201)Tl) and technetium-99m ((99m)Tc)-sestaMIBI biodistribution and kinetics. The clinical application of vasodilator stress for perfusion imaging requires consideration of the effects of these vasodilating agents on systemic hemodynamics, coronary flow, and radiotracer uptake and clearance kinetics. Sequential imaging and arterial blood sampling was performed on control, anesthetized closed-chest canines (n = 7) to evaluate radiotracer biodistribution and kinetics after either a bolus administration of regadenoson (2.5 microg/kg) or 4.5-min infusion of adenosine (280 microg/kg). The effects of regadenoson on coronary flow and myocardial radiotracer uptake were then evaluated in an open-chest canine model of a critical stenosis (n = 7). Results from ex vivo single-photon emission computed tomography were compared with tissue well-counting. The use of regadenoson compared favorably with adenosine in regard to the duration and magnitude of the hemodynamic effects and the effect on (201)Tl and (99m)Tc-sestaMIBI biodistribution and kinetics. The arterial blood clearance half-time was significantly faster for (99m)Tc-sestaMIBI (regadenoson: 1.4 +/- 0.03 min; adenosine: 1.5 +/- 0.08 min) than for (201)Tl (regadenoson: 2.5 +/- 0.16 min, p adenosine: 2.7 +/- 0.04 min, p regadenoson stress was significantly greater than the relative perfusion defect with (99m)Tc-sestaMIBI (0.69 +/- 0.03%, p regadenoson produced a hyperemic response comparable to a standard infusion of adenosine. The biodistribution and clearance of both (201)Tl and (99m)Tc-sestaMIBI during regadenoson were similar to adenosine vasodilation. Ex vivo perfusion images under the most ideal conditions permitted detection of a critical stenosis, although (201)Tl offered significant advantages over (99m

  13. Reversal of rest myocardial asynergy during exercise: a radionuclide scintigraphic study

    Energy Technology Data Exchange (ETDEWEB)

    Kimchi, A.; Rozanski, A.; Fletcher, C.; Maddahi, J.; Swan, H.J.; Berman, D.S.

    1985-11-01

    While exercise-induced segmental left ventricular wall motion abnormalities are well described, the phenomenon of improvement in certain asynergic segments during exercise in some patients remains a curiosity. To assess this unexpected finding, results were analyzed in 85 patients with wall motion abnormalities at rest who underwent two view exercise radionuclide ventriculography and exercise thallium-201 myocardial perfusion imaging. Wall motion was scored with a 5 point system; normalization or increase of 2 or more points with exercise signified improvement. Forty-eight patients (56%) had no change or further deterioration of wall motion at peak exercise, 15 (18%) showed both improvement of wall motion and deterioration and 22 (26%) showed only improvement of wall motion. Wall motion improvement during exercise was found in 57 (20%) of 279 segments with asynergy at rest. Of these 57 segments improving with exercise, 45 (79%) showed mild and 12 (21%) showed severe asynergy at rest. Only seven segments (12%) were associated with pathologic Q waves. Thallium-201 perfusion was normal in 44 segments (77%) while only 6 segments (11%) had reversible and only 7 (12%) had nonreversible thallium-201 defects. In conclusion segments with abnormal wall motion at rest that show improvement with exercise appear to represent viable nonischemic segments.

  14. Genotoxic and mutagenic effects of the diagnostic use of thallium-201 in nuclear medicine

    Energy Technology Data Exchange (ETDEWEB)

    Kelsey, K.T. (Harvard School of Public Health, Boston, MA (United States)); Donohoe, K.J. (Beth Israel Hospital, Boston, MA (United States). Div. of Nuclear Medicine); Baxter, Barbara; Memisoglu, Asli; Little, J.B.; Caggana, Michele; Liber, H.L. (Harvard School of Public Health, Boston, MA (United States))

    1991-07-01

    In order to investigate possible mutagenetic effects of in vivo exposure to low levels of ionizing radiation used in nuclear medicine, the authors examined hypoxanthine guanine phosphoribosyl transferase (hprt) mutant fraction (MF) and chromosome aberration (CA) frequency in 24 nuclear medicine patients before and after injection of thallium-201. The mean MF of the thallium-201-exposed cohort was 5.2{+-}4.4 x 10{sup -6} before injection exposure. No significant difference in MF was observed 24 h later. In 11 patients who were studied on a 3rd occasion, 30 days after thallium-201 exposure, there was again no significant difference in post-exposure as compared with the pre-exposure MF. The frequency of CA in peripheral blood lymphocytes was not significantly different, comparing pre- and 24h to 1 month post-radionuclide exposure . Thus, thallium-201 exposure was not associated with significant elevations in MF or CA frequency in lymphocytes of exposed individuals. (author). 40 refs.; 3 tabs.

  15. Myocardial perfusion scintigraphy: the evidence.

    Science.gov (United States)

    Underwood, S R; Anagnostopoulos, C; Cerqueira, M; Ell, P J; Flint, E J; Harbinson, M; Kelion, A D; Al-Mohammad, A; Prvulovich, E M; Shaw, L J; Tweddel, A C

    2004-02-01

    This review summarises the evidence for the role of myocardial perfusion scintigraphy (MPS) in patients with known or suspected coronary artery disease. It is the product of a consensus conference organised by the British Cardiac Society, the British Nuclear Cardiology Society and the British Nuclear Medicine Society and is endorsed by the Royal College of Physicians of London and the Royal College of Radiologists. It was used to inform the UK National Institute of Clinical Excellence in their appraisal of MPS in patients with chest pain and myocardial infarction. MPS is a well-established, non-invasive imaging technique with a large body of evidence to support its effectiveness in the diagnosis and management of angina and myocardial infarction. It is more accurate than the exercise ECG in detecting myocardial ischaemia and it is the single most powerful technique for predicting future coronary events. The high diagnostic accuracy of MPS allows reliable risk stratification and guides the selection of patients for further interventions, such as revascularisation. This in turn allows more appropriate utilisation of resources, with the potential for both improved clinical outcomes and greater cost-effectiveness. Evidence from modelling and observational studies supports the enhanced cost-effectiveness associated with MPS use. In patients presenting with stable or acute chest pain, strategies of investigation involving MPS are more cost-effective than those not using the technique. MPS also has particular advantages over alternative techniques in the management of a number of patient subgroups, including women, the elderly and those with diabetes, and its use will have a favourable impact on cost-effectiveness in these groups. MPS is already an integral part of many clinical guidelines for the investigation and management of angina and myocardial infarction. However, the technique is underutilised in the UK, as judged by the inappropriately long waiting times and by

  16. Nuclear medicine and coronary artery disease: evaluation of tracers of myocardial perfusion and vulnerable atherosclerotic plaque; Medecine nucleaire et maladie coronarienne: evaluation de traceurs de la perfusion myocardique et de la plaque d'atherome vulnerable

    Energy Technology Data Exchange (ETDEWEB)

    Broisat, A

    2005-04-15

    Coronary artery disease is one of the primary cause of mortality worldwide. Nuclear medicine is the major imaging technique for diagnosis and following of this disease. perfusion: nowadays, major radioactive agents used in clinical practice are myocardial perfusion tracers. The reference tracer is thallium-201. However, {sup 201}Tl presents some drawbacks. {sup 99m}Tcn-noet has been proposed for its replacement. This study shows that in contrast with previous studies realized in vitro on cardio myocytes, verapamil, an l-type calcium channel inhibitor, does not inhibit myocardial fixation of {sup 99m}Tcn-noet in vivo in dog. This data is in agreement with the hypothesis of a non specific endothelial fixation of this tracer. Moreover, this study shows that as a pure tracer of myocardial perfusion, {sup 99m}Tcn-noet can also be used to assess myocardial viability on a model of myocardial chronic infarction in rat. atherosclerosis: disruption of vulnerable atherosclerotic plaques is the main event leading to coronary accidents. The second part of this study concerns the evaluation of new potential tracers of the vulnerable atherosclerotic plaque in an experimental model of rabbit with an inheritable hypercholesterolemia. The four tracers evaluated (b2702(r), b2702-I, b2702-Tc and Tc-raft-b2702) are synthetic peptides comprising the residues 75-84 of hla-b2702, a molecule known to link vcam-1, an adhesion molecule expressed in vulnerable atherosclerotic plaque. The autoradiography studies show that all tracers accumulate within atherosclerotic plaque expressing vcam- and that. i-b2702 shows the best plaque/control fixation ratio. (author)

  17. Myocardial perfusion imaging with dual energy CT

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Kwang Nam [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiology, SMG-SNU Boramae Medical Center, Seoul (Korea, Republic of); De Cecco, Carlo N. [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Caruso, Damiano [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiological Sciences, Oncology and Pathology, University of Rome “Sapienza”, Rome (Italy); Tesche, Christian [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Cardiology and Intensive Care Medicine, Heart Center Munich-Bogenhausen, Munich (Germany); Spandorfer, Adam; Varga-Szemes, Akos [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC (United States)

    2016-10-15

    Highlights: • Stress dual-energy sCTMPI offers the possibility to directly detect the presence of myocardial perfusion defects. • Stress dual-energy sCTMPI allows differentiating between reversible and fixed myocardial perfusion defects. • The combination of coronary CT angiography and dual-energy sCTMPI can improve the ability of CT to detect hemodynamically relevant coronary artery disease. - Abstract: Dual-energy CT (DECT) enables simultaneous use of two different tube voltages, thus different x-ray absorption characteristics are acquired in the same anatomic location with two different X-ray spectra. The various DECT techniques allow material decomposition and mapping of the iodine distribution within the myocardium. Static dual-energy myocardial perfusion imaging (sCTMPI) using pharmacological stress agents demonstrate myocardial ischemia by single snapshot images of myocardial iodine distribution. sCTMPI gives incremental values to coronary artery stenosis detected on coronary CT angiography (CCTA) by showing consequent reversible or fixed myocardial perfusion defects. The comprehensive acquisition of CCTA and sCTMPI offers extensive morphological and functional evaluation of coronary artery disease. Recent studies have revealed that dual-energy sCTMPI shows promising diagnostic accuracy for the detection of hemodynamically significant coronary artery disease compared to single-photon emission computed tomography, invasive coronary angiography, and cardiac MRI. The aim of this review is to present currently available DECT techniques for static myocardial perfusion imaging and recent clinical applications and ongoing investigations.

  18. Syndrome of diminished vasodilator reserve of the coronary microcirculation (microvascular angina or syndrome X): Diagnosis by combined atrial pacing and thallium 201 imaging--a case report

    Energy Technology Data Exchange (ETDEWEB)

    Magarian, G.J.; Palac, R.; Reinhart, S. (Veterans Administration Medical Center, Portland, OR (USA))

    1990-08-01

    Patients with angina-like chest pain without evidence of epicardial coronary artery disease or coronary arterial vasospasm are becoming increasingly recognized. These are often related to noncardiac causes including esophageal, musculoskeletal, and hyperventilatory or panic states. However, recently a subgroup of such patients are being recognized as having true myocardial ischemia and chest pain on the basis of diminished coronary microvascular vasodilatory reserve (microvascular ischemia or Syndrome X). The authors describe such a patient who was found to have replication of anginal pain associated with a reversible ischemic defect on thallium 201 imaging during atrial pacing, suggesting ischemia in this myocardial segment. Resolution of angina and ST segment electrocardiographic changes of ischemia occurred with cessation of pacing. We believe this is the first report of a patient with this form of myocardial ischemia diagnosed by this method and should be considered in patients with anginal chest pain after significant coronary artery disease and coronary vasospasm have been excluded.

  19. Myocardial perfusion abnormalities in asymptomatic type 2 diabetic patients

    Directory of Open Access Journals (Sweden)

    Ghada Al-Humaidi

    2018-01-01

    Conclusions: We found a high prevalence of myocardial perfusion abnormalities in asymptomatic type 2 diabetic patients. Perfusion abnormalities on myocardial perfusion SPECT images were associated with disease duration, insulin use, nephropathy, and neuropathy. Asymptomatic diabetic patients might be candidates with CAD abnormalities that can be studied using myocardial perfusion SPECT.

  20. Meta-Analysis of Stress Myocardial Perfusion Imaging

    Science.gov (United States)

    2017-06-06

    Coronary Disease; Echocardiography; Fractional Flow Reserve, Myocardial; Hemodynamics; Humans; Magnetic Resonance Imaging; Myocardial Perfusion Imaging; Perfusion; Predictive Value of Tests; Single Photon Emission Computed Tomography; Positron Emission Tomography; Multidetector Computed Tomography; Echocardiography, Stress; Coronary Angiography

  1. Nonrigid registration of myocardial perfusion MRI

    DEFF Research Database (Denmark)

    Ólafsdóttir, Hildur

    2005-01-01

    This paper describes a fully automatic registration of 10 multi-slice myocardial perfusion magnetic resonance image sequences. The registration of these sequences is crucial for the clinical interpretation, which currently is subjected to manual labour. The approach used in this study is a nonrig...

  2. Measurement of myocardial perfusion using magnetic resonance

    DEFF Research Database (Denmark)

    Fritz-Hansen, T.; Jensen, L.T.; Larsson, H.B.

    2008-01-01

    Cardiac magnetic resonance imaging (MRI) has evolved rapidly. Recent developments have made non-invasive quantitative myocardial perfusion measurements possible. MRI is particularly attractive due to its high spatial resolution and because it does not involve ionising radiation. This paper reviews...

  3. Dilatation of the left ventricular cavity on dipyridamole thallium-201 imaging: A new marker of triple-vessel disease

    Energy Technology Data Exchange (ETDEWEB)

    Takeishi, Y.; Tono-oka, I.; Ikeda, K.; Komatani, A.; Tsuiki, K.; Yasui, S. (Yamagata Univ. School of Medicine (Japan))

    1991-02-01

    To investigate the significance and mechanism of dilatation of the left ventricular cavity on dipyridamole thallium-201 imaging, we performed both dipyridamole thallium-201 imaging and dipyridamole radionuclide angiography on 83 patients with known angiograms. The dipyridamole/delayed ratio of the left ventricular dimension from the thallium-201 image was defined as the left ventricular dilatation ratio (LVDR). An LVDR greater than the mean + two standard deviations in patients without coronary artery disease was defined as abnormal. Twenty-two of 83 patients showed an abnormal LVDR, and 18 of the 22 patients (82%) had triple-vessel disease. By defect and washout analysis, the sensitivity and specificity for correctly identifying the patients as having triple-vessel disease was 72% and 76%, respectively, whereas LVDR had a sensitivity of 72% and a specificity of 93%. When LVDR was used in combination with the defect and washout criteria, sensitivity increased to 84% without a loss of specificity. In those 22 patients with abnormal LVDRs, end-diastolic volume measured by radionuclide angiography did not change after dipyridamole infusion. Dilatation of the left ventricular cavity on dipyridamole thallium-201 imaging reflected relative subendocardial hypoperfusion induced by dipyridamole rather than actual chamber enlargement. The LVDR was moderately sensitive and highly specific for triple-vessel disease and provided complementary information to dipyridamole thallium-201 imaging.

  4. Myocardial perfusion at fatal infarction

    DEFF Research Database (Denmark)

    Hvid-Jacobsen, K; Møller, J T; Kjøller, E

    1992-01-01

    In a consecutive study of myocardial scintigraphy in acute ischemic syndrome, four patients had 99mTc-hexamibi injected intravenously before they developed fatal cardiogenic shock. Planar scintigraphy was performed after death. Slices of the hearts after autopsy were analyzed for scintigraphic...

  5. Regional myocardial perfusion and performance

    NARCIS (Netherlands)

    H.C. Schamhardt (Henk)

    1980-01-01

    textabstractThe function of the heart is to pump blood from the veins into the arteries in response to the need of the tissues for oxygen and substrates. During its action the heart itself needs these nutrients. Factors that mainly determine the myocardial oxygen demand are (fig.0.1): heart rate,

  6. Myocardial perfusion imaging in hyperthrophic cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Moorin, B. [Southland Hospital, Invercargill, (New Zealand). Department of Nuclear Medicine

    1998-06-01

    Full text: Patients with Hyperthrophic Cardiomyopathy (HCM) frequently suffer from syncope and cardiac arrest which may lead to sudden death. This is most often caused by ventricular arrhythmia`s in adults, however in young patients the mechanisms are thought to be different. Ischaemia may play a significant role even in young asymptomatic HCM patients. The mechanisms of ischaemic development in HCM differ from those in the `normal` myocardium (Due to intramural small vessel abnormalities and abnormal myocellular architecture). In HCM the coronary microcirculation is most often affected and massive hypertrophy means more energy is required to promote contraction thus increasing oxygen demand and compounding the effects of any ischaemic changes. A case of a 12 year old HCM patient is presented who has symptoms of syncope associated with exercise whose mother died suddenly of cardiac arrest developed from HCM. A myocardial perfusion rest/stress study was undertaken to detect any underlying myocardial ischaemia. Myocardial perfusion scintigraphy demonstrates any reduction in the microcirculation in addition to that present in the macrocirculation, unlike angiography which will only detect the latter. In this case the scan clearly showed evidence of ischaemia in the lateral wall and this may be an explanation for her episodes of syncope. We suggest an algorithm or the routine work-up of young patients with HCM which makes aggressive use of myocardial perfusion imaging to detect ischaemic changes. This may identify patients who are at higher risk and will assist with treatment decisions. We feel myocardial perfusion scintigraphy is a sensitive non-invasive accurate method of detecting microcirculatory ischaemia and is thus invaluable in HCM patients

  7. An alternative method for neonatal cerebro-myocardial perfusion

    Science.gov (United States)

    Luciani, Giovanni Battista; De Rita, Fabrizio; Faggian, Giuseppe; Mazzucco, Alessandro

    2012-01-01

    Several techniques have already been described for selective cerebral perfusion during repair of aortic arch pathology in children. One method combining cerebral with myocardial perfusion has also been proposed. A novel technique is reported here for selective and independent cerebro-myocardial perfusion for neonatal and infant arch surgery. Technical aspects and potential advantages are discussed. PMID:22307393

  8. Patient satisfaction with coronary CT angiography, myocardial CT perfusion, myocardial perfusion MRI, SPECT myocardial perfusion imaging and conventional coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Feger, S.; Rief, M.; Zimmermann, E.; Richter, F.; Roehle, R. [Freie Universitaet Berlin, Department of Radiology, Charite - Universitaetsmedizin Berlin Campus Mitte, Humboldt-Universitaet zu Berlin, Berlin (Germany); Dewey, M. [Freie Universitaet Berlin, Department of Radiology, Charite - Universitaetsmedizin Berlin Campus Mitte, Humboldt-Universitaet zu Berlin, Berlin (Germany); Institut fuer Radiologie, Berlin (Germany); Schoenenberger, E. [Medizinische Hochschule Hannover, Department of Medicine, Hannover (Germany)

    2015-07-15

    To evaluate patient acceptance of noninvasive imaging tests for detection of coronary artery disease (CAD), including single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI), stress perfusion magnetic resonance imaging (MRI), coronary CT angiography (CTA) in combination with CT myocardial stress perfusion (CTP), and conventional coronary angiography (CCA). Intraindividual comparison of perception of 48 patients from the CORE320 multicentre multinational study who underwent rest and stress SPECT-MPI with a technetium-based tracer, combined CTA and CTP (both with contrast agent, CTP with adenosine), MRI, and CCA. The analysis was performed by using a validated questionnaire. Patients had significantly more concern prior to CCA than before CTA/CTP (p < 0.001). CTA/CTP was also rated as more comfortable than SPECT-MPI (p = 0.001). Overall satisfaction with CT was superior to that of MRI (p = 0.007). More patients preferred CT (46 %; p < 0.001) as a future diagnostic test. Regarding combined CTA/CTP, CTP was characterised by higher pain levels and an increased frequency of angina pectoris during the examination (p < 0.001). Subgroup analysis showed a higher degree of pain during SPECT-MPI with adenosine stress compared to physical exercise (p = 0.016). All noninvasive cardiac imaging tests are well accepted by patients, with CT being the preferred examination. (orig.)

  9. Myocardial Perfusion Spect Imaging in Dextrocardia: A Case Report

    Directory of Open Access Journals (Sweden)

    Semra Özdemir

    2013-08-01

    Full Text Available The myocardial perfusion scintigraphy acquisition and analysis present some technical differences in the rare dextrocardia cases. Here we report a case of a 38 year-old woman with dextrocardia who had been applied myocardial perfusion scintigraphy. Presented case showed that the thoracic and abdominal organs had a mirror image with situs inversus totalis type dextrocardia. The incidence of coronary heart disease and life span of people with situs inversus totalis are the same as the normal population. So we may apply myocardial perfusion scintigraphy to this patient group. The current case is presented in order to remind the special applications of myocardial perfusion SPECT imaging in patients with dextrocardia.

  10. Regadenoson stress for myocardial perfusion imaging.

    Science.gov (United States)

    Reyes, Eliana

    2016-01-01

    Noninvasive functional imaging plays a major role in the diagnosis of hemodynamically significant coronary artery disease (CAD) by means of the detection of abnormal myocardial perfusion. For this, cardiac stressors are essential as they induce hypoperfusion in the presence of flow-limiting coronary stenosis. Several pharmacological stressors are currently available and it is important that clinicians who are involved in the care and management of patients with CAD become familiar with their indications, contraindications and protocols. Among the primary coronary vasodilator agents, regadenoson is increasingly used as the default stressor or as an alternative to other modalities of stress. This article provides an updated review of regadenoson stress for the assessment of patients with suspected or known CAD and describes its pharmacological properties, stress protocol, efficacy and safety profile.

  11. Thallium-201 SPECT in the diagnosis of head and neck cancer.

    Science.gov (United States)

    Valdés Olmos, R A; Balm, A J; Hilgers, F J; Koops, W; Loftus, B M; Tan, I B; Muller, S H; Hoefnagel, C A; Gregor, R T

    1997-06-01

    The accuracy of SPECT with 201Tl-chloride for the diagnosis of primary tumors, lymph node metastases and recurrences in head and neck cancer was evaluated for clinical applicability. SPECT images, obtained 60 min after administration of 150 MBq 201Tl-chloride, were compared with clinical, CT and/or MRI and histology results. In addition, whole-body images were obtained to detect distant metastases. In 79 patients studied for primary tumors (principally larynix, hypopharynx, oropharynx, nasopharynx and oral cavity), 201Tl SPECT correctly identified 69 of 73 (95% versus 88% for CT/MRI) histologically confirmed malignancies including 63 squamous-cell carcinomas. The method localized four occult naso- and oropharynx carcinomas not seen on CT/MRI and was correctly negative in two patients without tumor and in three of four patients with no confirmed primary tumor in the head and neck. With respect to regional spread, only patients who had cervical lymph node dissection were evaluated, and the findings were recorded per side of the neck. Thallium-201 SPECT correctly identified metastases in 31 of 36 neck dissections with proven lymph node involvement (86%), was correctly negative in nine and false-positive in one. Although the sensitivity of CT/MRI was clearly higher (97%), considerably more false-positive cases affected its accuracy (81% versus 87% for SPECT). In 30 patients investigated for recurrences, 201Tl SPECT correctly identified 27 of 29 microscopically confirmed tumor sites (93%) and was correctly negative in seven. Sensitivity of CT/MRI was lower (76%), and a greater number of false-positives (seven versus three for SPECT) further decreased its accuracy (64% versus 87% for SPECT). Distant metastases were detected in five patients. Thallium-201 SPECT appears to be an accurate method for the diagnosis of head and neck cancer. The method is particularly useful for detection of occult head and neck tumors and for assessing recurrences. It also may be of

  12. Adenosine myocardial perfusion single-photon emission computed tomography in women compared with men. Impact of diabetes mellitus on incremental prognostic value and effect on patient management.

    Science.gov (United States)

    Berman, Daniel S; Kang, Xingping; Hayes, Sean W; Friedman, John D; Cohen, Ishac; Abidov, Aiden; Shaw, Leslee J; Amanullah, Aman M; Germano, Guido; Hachamovitch, Rory

    2003-04-02

    This study was designed to assess the incremental prognostic value of adenosine stress myocardial perfusion single-photon emission computed tomography (MPS) in women versus men, and to explore the prognostic impact of diabetes mellitus. Limited data are available regarding the incremental value of adenosine stress MPS for the prediction of cardiac death in women versus men and the impact of diabetes mellitus on post-adenosine MPS outcomes. Of 6,173 consecutive patients who underwent rest thallium-201/adenosine technetium-99m sestamibi MPS, 254 (4.1%) were lost to follow-up, and 586 with early revascularization women and 2,677 men. Women had significantly smaller adenosine stress, rest, and reversible defects than men. During 27.0 +/- 8.8 month follow-up, cardiac death rates were lower in women than men (2.0%/year vs. 2.7%/year, respectively, p men and women as a function of MPS results. Multivariable models revealed that MPS results provided incremental prognostic value over pre-scan data for the prediction of cardiac death in both genders. Also, while comparative unadjusted rates of early (women (p men and women. Importantly, diabetic women had a significantly greater risk of cardiac death compared with other patients. Also, after risk adjustment, patients with insulin-dependent diabetes mellitus (IDDM) had higher risk of cardiac death for any MPS result than patients with non-insulin-dependent diabetes mellitus. The findings suggest that adenosine MPS has comparable incremental value for prediction of cardiac death in women and men and that MPS is appropriately influencing subsequent invasive management decisions in both genders. Diabetic women and patients with IDDM appear to have greater risk of cardiac death than other patients for any MPS result.

  13. Quantification of myocardial perfusion by cardiovascular magnetic resonance.

    Science.gov (United States)

    Jerosch-Herold, Michael

    2010-10-08

    The potential of contrast-enhanced cardiovascular magnetic resonance (CMR) for a quantitative assessment of myocardial perfusion has been explored for more than a decade now, with encouraging results from comparisons with accepted "gold standards", such as microspheres used in the physiology laboratory. This has generated an increasing interest in the requirements and methodological approaches for the non-invasive quantification of myocardial blood flow by CMR. This review provides a synopsis of the current status of the field, and introduces the reader to the technical aspects of perfusion quantification by CMR. The field has reached a stage, where quantification of myocardial perfusion is no longer a claim exclusive to nuclear imaging techniques. CMR may in fact offer important advantages like the absence of ionizing radiation, high spatial resolution, and an unmatched versatility to combine the interrogation of the perfusion status with a comprehensive tissue characterization. Further progress will depend on successful dissemination of the techniques for perfusion quantification among the CMR community.

  14. Myocardial Perfusion Spect Imaging in Dextrocardia: A Case Report

    Science.gov (United States)

    Özdemir, Semra; Gazi, Emine

    2013-01-01

    The myocardial perfusion scintigraphy acquisition and analysis present some technical differences in the rare dextrocardia cases. Here we report a case of a 38 year-old woman with dextrocardia who had been applied myocardial perfusion scintigraphy. Presented case showed that the thoracic and abdominal organs had a mirror image with situs inversus totalis type dextrocardia. The incidence of coronary heart disease and life span of people with situs inversus totalis are the same as the normal population. So we may apply myocardial perfusion scintigraphy to this patient group. The current case is presented in order to remind the special applications of myocardial perfusion SPECT imaging in patients with dextrocardia. Conflict of interest:None declared. PMID:24003402

  15. Follow-up Thallium-201 scintigraphy after mantle field radiotherapy for Hodgkin's disease

    Energy Technology Data Exchange (ETDEWEB)

    Pierga, J.Y.; Girinski, T.; Henry-Amar, M. (Institut Gustave Roussy, Villejuif (France)); Maunoury, C.; Valette, H.; Tchernia, G.; Desgrez, A. (Centre Hospitalier de Bicetre, Le Kremlin-Bicetre (France)); Socie, G. (Institut Gustave Roussy, Villejuif (France) Hopital St Louis, Paris (France)); Cosset, J.M. (Institut Gustave Roussy, Villejuif (France) Institut Curie, Paris (France))

    1993-04-02

    Assessment of the long-term cardiac effects of mediastinal radiotherapy for Hodgkin's disease, by Thallium scintigraphy. 32 patients (14 males and 18 females) who underwent mantle field radiotherapy for Hodgkin's disease were included in this study. Twenty patients received 4 fractions of 2.5 Gy per week and 12, five fraction of 2 Gy per week, delivered on alternate days. All the patients, except three, performed exercise testing electrocardiogram and Thallium-201 tomoscintigraphy. The average time interval from completion of treatment to the study was 7 years (range 3--13 years). No patients had clinical symptoms of cardiac disease. Mean age at the time of the study was 35 years (range 23--48 years). Two electrocardiograms revealed left bundle branch block and the patients were excluded from the study. Only one out of 27 exercise electrocardiograms was abnormal in a patient with mitral valve prolapse, who was also excluded from the study. Twenty-six scintigraphies were evaluable. Twenty-two (85%) were clearly abnormal with partial or complete redistribution on delayed images. The anterior region was affected in 19 of these cases (86%). Four explorations were undoubtedly normal. Coronary angiography was not performed for ethical reasons in these asymptomatic patients. Despite possible false positive tests, the high rate of abnormality (85%) in this small series is striking. These preliminary data justify larger studies and a close long-term follow-up of these patients. 24 refs., 1 fig., 2 tabs.

  16. Myocardial perfusion in type 2 diabetes with left ventricular hypertrophy

    DEFF Research Database (Denmark)

    Hesse, Birger; Meyer, Christian; Nielsen, Flemming S

    2004-01-01

    with PET using nitrogen-13 ammonia infused at rest and during dipyridamole hyperaemia. Twelve healthy control subjects were included in the study, five of whom were also studied with perindoprilat. Mean blood pressure in normo-albuminuric, asymptomatic patients was 123+/-7/65+/-9 mmHg. Compared......The purpose of this study was to assess whether acute angiotensin-converting enzyme (ACE) inhibition would improve myocardial perfusion and perfusion reserve in a subpopulation of normotensive patients with diabetes and left ventricular hypertrophy (LVH), both independent risk factors of coronary...... disease. Using positron emission tomography (PET), we investigated the response of regional myocardial perfusion to acute ACE inhibition with i.v. infusion of perindoprilat (vs saline infusion as control, minimum interval 3 days) in 12 diabetic patients with LVH. Myocardial perfusion was quantified...

  17. Increases in myeloperoxidase levels after exercise in myocardial perfusion scintigraphy are not induced by myocardial ischemia

    NARCIS (Netherlands)

    van der Zee, P. M.; Meuwese, M. C.; Verberne, H. J.; de Ruijter, M.; van Straalen, J. P.; Fischer, J. C.; Sturk, A.; van Eck-Smit, B. L. F.; Stroes, E. S. G.; de Winter, R. J.

    2008-01-01

    Background: Increased systemic levels of myeloperoxidase (MPO) have been reported in patients with acute myocardial ischemia. We studied the association between exercise-induced myocardial ischemia measured by myocardial perfusion scintigraphy (MPS) and the magnitude and time course of changes in

  18. MRI and thallium-201 SPECT in the prediction of survival in glioma

    Energy Technology Data Exchange (ETDEWEB)

    Vos, Maaike J. [VU University Medical Center, Department of Neurology, Amsterdam (Netherlands); Medical Center Haaglanden, Department of Neurology, PO Box 432, The Hague (Netherlands); Berkhof, Johannes [VU University Medical Center, Department of Epidemiology and Biostatistics, Amsterdam (Netherlands); Hoekstra, Otto S. [VU University Medical Center, Department of Nuclear Medicine and PET Research, Amsterdam (Netherlands); Bosma, Ingeborg; Sizoo, Eefje M.; Heimans, Jan J.; Reijneveld, Jaap C.; Postma, Tjeerd J. [VU University Medical Center, Department of Neurology, Amsterdam (Netherlands); Sanchez, Esther [VU University Medical Center, Department of Radiology, Amsterdam (Netherlands); Lagerwaard, Frank J. [VU University Medical Center, Department of Radiation Oncology, Amsterdam (Netherlands); Buter, Jan [VU University Medical Center, Department of Medical Oncology, Amsterdam (Netherlands); Noske, David P. [VU University Medical Center, Department of Neurosurgery and Neuro-Oncology Research Group, Amsterdam (Netherlands)

    2012-06-15

    This paper aims to study the value of MRI and Thallium 201 ({sup 201}Tl) single-photon emission computed tomography (SPECT) in the prediction of overall survival (OS) in glioma patients treated with temozolomide (TMZ) and to evaluate timing of radiological follow-up. We included patients treated with TMZ chemoradiotherapy for newly diagnosed glioblastoma multiforme (GBM) and with TMZ for recurrent glioma. MRIs and {sup 201}Tl SPECTs were obtained at regular intervals. The value of both imaging modalities in predicting OS was examined using Cox regression analyses. Altogether, 138 MRIs and 113 {sup 201}Tl SPECTs in 46 patients were performed. Both imaging modalities were strongly related to OS (P {<=} 0.02). In newly diagnosed GBM patients, the last follow-up MRI (i.e., after six adjuvant TMZ courses) and SPECT (i.e., after three adjuvant TMZ courses) were the strongest predictors of OS (P = 0.01). In recurrent glioma patients, baseline measurements appeared to be the most predictive of OS (P < 0.01). The addition of one imaging modality to the other did not contribute to the prediction of OS. Both MRI and {sup 201}Tl SPECT are valuable in the prediction of OS. It is adequate to restrict to one of both modalities in the radiological follow-up during treatment. In the primary GBM setting, MRI after six adjuvant TMZ courses contributes significantly to the prediction of survival. In the recurrent glioma setting, baseline MRI appears to be a powerful predictor of survival, whereas follow-up MRIs during TMZ seem to be of little additional value. (orig.)

  19. Thallium-201 for cardiac stress tests: residual radioactivity worries patients and security.

    Science.gov (United States)

    Geraci, Matthew J; Brown, Norman; Murray, David

    2012-12-01

    A 47-year-old man presented to the Emergency Department (ED) in duress and stated he was "highly radioactive." There were no reports of nuclear disasters, spills, or mishaps in the local area. This report discusses the potential for thallium-201 (Tl-201) patients to activate passive radiation alarms days to weeks after nuclear stress tests, even while shielded inside industrial vehicles away from sensors. Characteristics of Tl-201, as used for medical imaging, are described. This patient was twice detained by Homeland Security Agents and searched after he activated radiation detectors at a seaport security checkpoint. Security agents deemed him not to be a threat, but they expressed concern regarding his health and level of personal radioactivity. The patient was subsequently barred from his job and sent to the hospital. Tl-201 is a widely used radioisotope for medical imaging. The radioactive half-life of Tl-201 is 73.1h, however, reported periods of extended personal radiation have been seen as far out as 61 days post-administration. This case describes an anxious, but otherwise asymptomatic patient presenting to the ED with detection of low-level personal radiation. Documentation should be provided to and carried by individuals receiving radionuclides for a minimum of five to six half-lives of the longest-lasting isotope provided. Patients receiving Tl-201 should understand the potential for security issues; reducing probable tense moments, confusion, and anxiety to themselves, their employers, security officials, and ED staff. Copyright © 2012 Elsevier Inc. All rights reserved.

  20. Usefulness of thallium-201 SPECT in the evaluation of tumor natures in intracranial meningiomas

    Energy Technology Data Exchange (ETDEWEB)

    Takeda, Tetsuji; Nakano, Takahiro; Asano, Kenichiroh; Shimamura, Norihito; Ohkuma, Hiroki [Hirosaki University Graduate School of Medicine, Department of Neurosurgery, Hirosaki (Japan)

    2011-11-15

    Although intracranial meningiomas are regarded as benign tumors, some of them behave clinically as malignant tumors. Past reports suggest that MIB 1 and vascular endothelial growth factor (VEGF) in postoperative tumor specimens correlate with the aggressive nature of tumors, but preoperative prediction of such a nature is more useful for therapeutic planning for the tumor. The purpose of this study was to assess the usefulness of preoperative thallium-201 chloride single-photon emission computed tomography (Tl SPECT) to evaluate biological behavior in intracranial meningiomas. Tl SPECT was performed on 39 patients with intracranial meningioma and Tl uptake indices were calculated. The difference in the Tl uptake index between atypical meningiomas and other pathological types of meningioma was evaluated. Moreover, correlation of Tl uptake indices with the MIB1 labeling index was estimated. Tl uptake indices were also compared between VEGF strongly positive and weakly positive meningiomas. The delayed index of atypical meningioma was significantly higher than that of the other pathological types (p = 0.036). Significant correlation was found between the Tl uptake index in the delayed image and MIB1 labeling index (p < 0.0001, R{sup 2} = 0.36). Moreover, VEGF strongly positive meningiomas exhibited a significantly higher Tl uptake index compared to VEGF weakly positive meningiomas in both the early image and the delayed image (p = 0.029, 0.023, respectively). Tl uptake index may be a possible preoperative surrogate marker of MIB1 and VEGF that is useful in detecting aggressive natures in intracranial meningiomas. (orig.)

  1. Clinical usefulness of myocardial scintigraphy for diagnosis of ischemic heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Tsuji, Sotoyuki; Murakami, Eiji; Takekoshi, Noboru (Kanazawa Medical Univ. (Japan))

    1983-03-01

    Methods for noninvasive diagnosis an evaluation of coronary artery disease have been dramatically advanced by the development of myocardial scintigraphy. In this paper, 225 patients with coronary artery disease were studied with the following results: (1) With the use of 99mTc-PYP acute myocardial infarction areas were successfully detected in 80 % of the patients. (2) In the detection of myocardial infarction coincidence of the location of scan site defined by electrocardiogram with that of thallium defect at rest was 72 %. Coincidence of the area of dyssynergy in left ventriculogram with the site of thallium defect was 79 %. (3) The sensitivity of thallium-201 myocardial scintigram was 54 % and the specificity was 82 % in detecting angina pectoris. In detecting myocardial infarction the sensitivity was 81 % and the specificity was 75 %. In LCX the sensitivity of thallium-201 decreased considerably. (4) The sensitivity and specificity of thallium-201 imaging in detection of coronary artery disease after exercise were 78 % and 63 %, respectively.

  2. Role of CMR in assessment of myocardial perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Prasad, S.K.; Lyne, J.; Chai Ping; Gatehouse, P. [Cardiovascular Magnetic Resonance Unit, Royal Brompton Hospital, London (United Kingdom)

    2005-02-01

    Ischaemic heart disease is a major cause of morbidity and mortality. Assessment of myocardial perfusion is important in assessing the severity and extent of coronary artery lesions and in helping to guide revascularisation strategies where stenoses are documented. It provides information on the haemodynamic significance and a guide to prognosis. There has been much interest in the role of CMR assessment of perfusion and the opportunity for subendocardial resolution. We present an overview on its current status. (orig.)

  3. Direct myocardial perfusion imaging in valvular heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Soto, R.C.; Durante, M.L.; Villacorta, E.V.; Torres, J.F.; Monzon, O.P.

    1981-02-01

    Twenty two patients with rheumatic valvular heart disease - 21 having a history of heart failure - were studied using direct coronary injection of /sup 99m/Tc labelled MAA particles during the course of hemodynamic and arteriographic studies. Myocardial perfusion deficit patterns have been shown to be consistent or indicative of either patchy, regional or gross ischemia. In patients with history of documented heart failure 90% (18 cases) had ischemic perfusion deficit in the involved ventricle. We conclude that diminished myocardial blood flow is an important mechanism contributing to the development of heart failure.

  4. Simvastatin may improve myocardial perfusion abnormality in slow coronary flow.

    Science.gov (United States)

    Cakmak, Mahmut; Tanriverdi, Halil; Cakmak, Nazmiye; Evrengul, Harun; Cetemen, Sebnem; Kuru, Omur

    2008-01-01

    The slow coronary flow (SCF) phenomenon is a coronary microvascular disorder characterized by the delayed passage of contrast in the absence of obstructive epicardial coronary disease. Recent studies showed the possible role of endothelial dysfunction, diffuse atherosclerosis and inflammation in the pathogenesis of this phenomenon. We aimed to investigate the effect of statin on myocardial perfusion in patients with SCF. The study population consisted of 97 patients with SCF. Coronary flow patterns of the cases are determined by thrombolysis in myocardial infarction (TIMI) frame count method. Single-photon emission computed tomographic myocardial perfusion imaging studies and lipid parameters of the patients were obtained before and after 6 months of simvastatin treatment period. During the study, daily single dose of 40 mg simvastatin has been given to each subject. We found a significant positive correlation between mean TIMI frame count and basal reversibility score (r = 0.84, p = 0.0001). In addition, analysis of the reversibility scores demonstrates that simvastatin treatment has significantly improved the myocardial perfusion abnormality at the end of the follow-up period. Present findings allow us to conclude that simvastatin improved myocardial perfusion in patients with SCF.

  5. Quantification of myocardial perfusion by cardiovascular magnetic resonance

    OpenAIRE

    Jerosch-Herold Michael

    2010-01-01

    Abstract The potential of contrast-enhanced cardiovascular magnetic resonance (CMR) for a quantitative assessment of myocardial perfusion has been explored for more than a decade now, with encouraging results from comparisons with accepted "gold standards", such as microspheres used in the physiology laboratory. This has generated an increasing interest in the requirements and methodological approaches for the non-invasive quantification of myocardial blood flow by CMR. This review provides a...

  6. Factors affecting thrombolysis in myocardial infarction myocardial perfusion frame count: insights of myocardial tissue-level reperfusion from a novel index for assessing myocardial perfusion.

    Science.gov (United States)

    Pu, Jun; Shan, Pei-ren; Ding, Song; Qiao, Zhi-qin; Jiang, Li-sheng; Song, Wei; DU, Yong-ping; Shen, Jie-yan; Shen, Lin-hong; Jin, Shu-xuan; He, Ben

    2011-03-01

    Myocardial tissue-level perfusion failure is associated with adverse outcomes following ST-elevation myocardial infarction (STEMI) despite successful epicardial recanalization. We have developed a new quantitative index-thrombolysis in myocardial infarction (TIMI) myocardial perfusion frame count (TMPFC)--for assessing myocardial tissue level perfusion. However, factors affecting this novel index of myocardial perfusion are currently unknown. A total of 255 consecutive STEMI patients undergoing primary angioplasty were enrolled. Myocardial tissue level perfusion was assessed by TMPFC, which measures the filling and clearance of contrast in the myocardium using cine-angiographic frame counting. We differentiate three groups with two cut off values for TMPFC: a TMPFC of 90 frames was the upper boundary of the 95% confidence interval (CI) for the TMPFC observed in normal arteries, and a TMPFC of 130 was the 75th percentile of TMPFC. STEMI patients with TMPFC > 130 frames (68 patients, 26.7%) had higher clinical and angiographic risk factor profiles as well as a higher 30-day MACE rate compared with those with TMPFC ≤ 90 frames and those with TMPFC > 90 and ≤ 130 frames. Multivariable analysis identified that the independent predictors of TMPFC > 130 frames were age ≥ 75 years (OR 2.08, 95%CI 1.21 to 3.58, P = 0.007), diabetes (OR 1.37, 95%CI 1.01 to 1.86, P = 0.042), Killip class ≥ 2 (OR 1.52, 95%CI 1.05 to 2.21, P = 0.027), and prolonged pain-to-balloon time (OR 1.73, 95%CI 1.07 to 2.79, P = 0.013). TMPFC > 130 frames was identified as the strongest independent predictor of 30-day major adverse cardiac event (MACE) (OR 2.77, 95%CI 1.21 to 6.31, P = 0.008), along with age ≥ 75 years (OR 2.19, 95%CI 1.11 to 4.33, P = 0.016), female gender (OR 1.67, 95%CI 1.03 to 2.70, P = 0.038), and Killip class ≥ 2 (OR 1.83, 95%CI 1.07 to 3.14, P = 0.021). STEMI patients with poor myocardial perfusion assessed by TMPFC had higher risk factor profiles. Advanced age

  7. Comparison of arbutamine stress and treadmill exercise thallium-201 SPECT: Hemodynamics, safety profile and diagnostic accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Kiat, H.; Berman, D.S. [Cedars-Sinai Medical Centre, Los Angeles, California, LA (United States)

    1998-02-01

    Full text: Arbutamine (ARB), a new pharmacologic stress agent with enhanced chronotropic property compared to dobutamine, was compared with treadmill (TM) exercise testing (Ex) in a multicenter study using thallium-201 (Tl) SPECT. Of the total of 184 patients who underwent ARB, 69 also had TM stress and quantitative coronary angiography. Fifty-eight patients with a low pretest likelihood of CAD also underwent ARB study for evaluation of test specificity (normalcy rate). Tl scans were scored by a central laboratory using a 20 segment (seg)/scan visual analysis (5 point system: 0=normal, 4-absent uptake). Maximum heart rate (HR) by ARB and Ex was 122 vs 141 bpm (p<0.05). Mean %HR change from baseline was similar (79% vs 82%, respectively, p=ns). Maximum systolic BP for ARB and Ex was 173 vs 175 mmHg, and mean % change from baseline was 24% vs 28% (p=ns). Sensitivity for detecting CAD (270% stenosis) by ARB Tl was 94% and 97% by Ex Tl (p=ns). Stress Tl SPECT segmental agreement for presence of defect between ARB and Ex was 92% (kappa=0.8, p<0.001). Exact segmental stress Tl score (0-4 grading) agreement was 83 % (kappa=0.7, p<0.001). Among 346 segs with stress defects by both ARB and Ex defect reversibility agreement was 86% (kappa=0.7, p<0.001). The normalcy rate for ARB TI-SPECT among patients with a low likelihood of CAD was 90%. Adverse events were mostly mild (tremor: 23%, flushing: 10%, headache: 10%, paraesthesia: 8%, dizziness: 8%, hot flushes: 4%). Arrhythimia of clinical concern occurred in 8% (10/122) of ARB patients who had cardiac catheterisation and in 1.4% (1/69) of patients who had stress Tl. Of all 184 patients with ARB stress, ARB was discontinued due to arrhythmia in 7(5%) and 1 patient had IV Metoprolol for frequent ventricular couplets. Sustained arrhythmias were not observed

  8. Quantification of myocardial perfusion by cardiovascular magnetic resonance

    Directory of Open Access Journals (Sweden)

    Jerosch-Herold Michael

    2010-10-01

    Full Text Available Abstract The potential of contrast-enhanced cardiovascular magnetic resonance (CMR for a quantitative assessment of myocardial perfusion has been explored for more than a decade now, with encouraging results from comparisons with accepted "gold standards", such as microspheres used in the physiology laboratory. This has generated an increasing interest in the requirements and methodological approaches for the non-invasive quantification of myocardial blood flow by CMR. This review provides a synopsis of the current status of the field, and introduces the reader to the technical aspects of perfusion quantification by CMR. The field has reached a stage, where quantification of myocardial perfusion is no longer a claim exclusive to nuclear imaging techniques. CMR may in fact offer important advantages like the absence of ionizing radiation, high spatial resolution, and an unmatched versatility to combine the interrogation of the perfusion status with a comprehensive tissue characterization. Further progress will depend on successful dissemination of the techniques for perfusion quantification among the CMR community.

  9. Role of myocardial perfusion single photon emission computed tomography in pediatric cardiology practice

    Directory of Open Access Journals (Sweden)

    Sundaram P

    2009-01-01

    Full Text Available Diagnostic and prognostic power of myocardial perfusion imaging in patients with coronary artery disease has been demonstrated with planar imaging which was further improvised with addition of gated SPECT and newer Technetium labeled myocardial perfusion tracers like SestaMIBI, Tetrofosmin. Myocardial perfusion abnormalities at rest and after stress are considered to be the best predictors of cardiac event-free survival in adults with ischemic heart disease. This article highlights various myocardial perfusion imaging (MPIradiopharmaceuticals, exercise procedures, pharmacological stress protocols, indications for MPI and myocardial perfusion patterns in children with some of the common congenital and acquired heart diseases.

  10. Non-invasive imaging in detecting myocardial viability: Myocardial function versus perfusion

    Directory of Open Access Journals (Sweden)

    Iqbal A. Elfigih

    2014-12-01

    Full Text Available Coronary artery disease (CAD is the most prevalent and single most common cause of morbidity and mortality [1] with the resulting left ventricular (LV dysfunction an important complication. The distinction between viable and non-viable myocardium in patients with LV dysfunction is a clinically important issue among possible candidates for myocardial revascularization. Several available non-invasive techniques are used to detect and assess ischemia and myocardial viability. These techniques include echocardiography, radionuclide images, cardiac magnetic resonance imaging and recently myocardial computed tomography perfusion imaging. This review aims to distinguish between the available non-invasive imaging techniques in detecting signs of functional and perfusion viability and identify those which have the most clinical relevance in detecting myocardial viability in patients with CAD and chronic ischemic LV dysfunction. The most current available studies showed that both myocardial perfusion and function based on non-invasive imaging have high sensitivity with however wide range of specificity for detecting myocardial viability. Both perfusion and function imaging modalities provide complementary information about myocardial viability and no optimum single imaging technique exists that can provide very accurate diagnostic and prognostic viability assessment. The weight of the body of evidence suggested that non-invasive imaging can help in guiding therapeutic decision making in patients with LV dysfunction.

  11. Early and Delayed Myocardial Enhancement in Myocardial Infarction Using Two-Phase Contrast-Enhanced Multidetector-Row CT

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Sung-Min; Kim, Young-Whan; Han, Seong-Wook [University of Keimyung College of Medicine, Dongsan Medical Center, Daegu (Korea, Republic of); Seo, Joon-Beom [University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2007-04-15

    The purpose of this study was to describe the myocardial enhancement patterns in patients with myocardial infarction using two-phase contrast enhanced multidetector-row computed tomography (MDCT). Twenty-three patients with clinically proven myocardial infarction (17 acute myocardial infarction [AMI] and 6 chronic myocardial infarction [CMI]) were examined with two-phase contrast-enhanced ECG-gated MDCT. The presence, location, and patterns of myocardial enhancement on two phase MDCT images were compared with infarcted myocardial territories determined by using electrocardiogram, echocardiography, thallium-201 single photon emission computed tomography, catheter and MDCT coronary angiography. After clinical assessment, the presence of myocardial infarctions were found in 27 territories (19 AMI and 8 CMI) of 23 patients. Early perfusion defects were observed in 30 territories of all 23 patients. Three territories not corresponding to a myocardial infarction were detected in three patients with AMI and were associated with artifacts. Fourteen of perfusion defects were in the left anterior descending artery territory, four in the left circumflex artery territory, and nine in the right coronary artery territory. Delayed enhancement was observed in 25 territories (17 AMI and 8 CMI) of 21 patients. Delayed enhancement patterns were variable. Transmural early perfusion defects (n =12) were closely associated with transmural late enhancement (n = 5) and subendocardial residual defect with subepicardial late enhancement (n = 5). Myocardial infarction showed early perfusion defects and variable delayed enhancement patterns on two-phase contrast-enhanced MDCT. Delayed enhancement technique of MDCT could provide additional information of the location and extent of infarcted myocardium, and could be useful to plan appropriate therapeutic strategies in patients with AMI.

  12. Quantitative myocardial perfusion measurement using CT perfusion: a validation study in a porcine model of reperfused acute myocardial infarction.

    Science.gov (United States)

    So, Aaron; Hsieh, Jiang; Li, Jian-Ying; Hadway, Jennifer; Kong, Hua-Fu; Lee, Ting-Yim

    2012-06-01

    We validated a CT perfusion technique with beam hardening (BH) correction for quantitative measurement of myocardial blood flow (MBF). Acute myocardial infarction (AMI) was created in four pigs by occluding the distal LAD for 1 h followed by reperfusion. MBF was measured from dynamic contrast enhanced CT (DCE-CT) scanning of the heart, with correction of cardiac motion and BH, before ischemic insult and on day 7, 10 and 14 post. On day 14 post, radiolabeled microspheres were injected to measure MBF and the results were compared with those measured by CT perfusion. Excised hearts were stained with 2,3,5-triphenyltetrazolium chloride (TTC) to determine the relationship between MBF measured by CT Perfusion and myocardial viability. MBF measured by CT perfusion was strongly correlated with that by microspheres over a wide range of MBF values (R = 0.81, from 25 to 225 ml min(-1) 100 g(-1)). While MBF in the LAD territory decreased significantly from 98.4 ± 2.5 ml min(-1) 100 g(-1) at baseline to 32.2 ± 9.1 ml min(-1) 100 g(-1), P 0.05). TTC staining confirmed incomplete infarction in the LAD territory and no infarction in the LCx territory. Microvascular obstruction in infarcted tissue resulted in no-reflow and hence persistently low MBF in the reperfused LAD territory which contained a mixture of viable and non-viable tissue. CT perfusion measurement of MBF was accurate and correlated well with histology and microspheres measurements.

  13. Stress-only myocardial perfusion scintigraphy

    DEFF Research Database (Denmark)

    Ejlersen, June A; May, Ole; Mortensen, Jesper

    2017-01-01

    OBJECTIVE: Patients with normal stress perfusion have an excellent prognosis. Prospective studies on the diagnostic accuracy of stress-only scans with contemporary, independent examinations as gold standards are lacking. PATIENTS AND METHODS: A total of 109 patients with typical angina and no pre...

  14. Tomographic myocardial perfusion scintigraphy in children with Kawasaki disease

    Energy Technology Data Exchange (ETDEWEB)

    Spielmann, R.P.; Nienaber, C.A.; Hausdorf, G.; Montz, R.

    1987-12-01

    Myocardial infarction and stenotic coronary lesions are serious late complications in children with Kawasaki disease. For the noninvasive assessment of myocardial perfusion, dipyridamole-redistribution /sup 201/Tl emission computed tomography (ECT) was performed in seven children (age 2 8/12-8 7/12 yr) 3-20 mo after the acute stage of the disease. In all patients, coronary aneurysms had been demonstrated by cross-sectional echocardiography. The scintigrams of six children showed no significant regional reduction of myocardial thallium uptake. These children had remained asymptomatic since the acute stage of Kawasaki disease. Persistent and transient thallium defects were present in one child with documented myocardial infarction. For this patient, obstruction of corresponding coronary vessels was confirmed by contrast angiography. It is suggested, that /sup 201/Tl ECT after dipyridamole-induced vasodilation may be used as a safe alternative to invasive coronary angiography for follow-up investigations in patients with Kawasaki disease.

  15. Influence of attenuation correction on transient left ventricular dilation in dual isotope myocardial perfusion imaging in patients with known or suspected coronary artery disease.

    Science.gov (United States)

    Brodov, Yafim; Frenkel, Alex; Chouraqui, Pierre; Przewloka, Kinga; Rispler, Shmuel; Abadi, Sobhi; Keidar, Zohar

    2012-07-01

    The aim of this study was to assess the effect of attenuation correction (AC) on left ventricular (LV) volumes and LV transient ischemic dilatation (TID) during dual-isotope single-photon emission computer tomographic (SPECT) myocardial perfusion imaging (MPI). Ninety-six patients (mean age 58 ± 11 years, 15% women, 38 patients completed exercise and 58 dipyridamole pharmacologic stress tests) assessed for known or suspected coronary artery disease underwent dual-isotope thallium-201 rest and technetium-99m sestamibi stress SPECT MPI with computed tomography-based AC. The TID ratio was calculated separately for non-AC and AC SPECT MPI studies as the ratio of the LV endocardial volume at stress divided by LV endocardial volume at rest. The mean and range of the gated LV ejection fraction during exercise and pharmacologic stress was 54 ± 12% (29% to 80%) and 58 ± 12% (27% to 80%), respectively. In the exercise stress group, the same mean LV endocardial volumes in non-AC and AC stress (76.4 ± 30 and 76.5 ± 28) and rest (66.3 ± 26 and 66.4 ± 24) studies were found (p = 0.90). There was no statistical difference between the mean exercise TID ratio in non-AC and AC studies (1.27 vs 1.31, respectively, p = 0.10). The same mean LV endocardial volumes in non-AC and AC in pharmacologic stress (79.9 ± 42 and 80 ± 41) and rest (71.4 ± 41 and 72.3 ± 37), respectively, were found (p = 0.50). There was no statistical difference between the mean dipyridamole TID ratio in non-AC and AC studies (1.20 vs 1.17, respectively, p = 0.10). In conclusion, LV volumes and TID indexes obtained on SPECT MPI with exercise or pharmacologic stress using dipyridamole are not affected by AC. Copyright © 2012 Elsevier Inc. All rights reserved.

  16. Decreased myocardial perfusion reserve in diabetic autonomic neuropathy

    DEFF Research Database (Denmark)

    Taskiran, Mustafa; Fritz-Hansen, Thomas; Rasmussen, Verner

    2002-01-01

    conditions and after Dipyridamole-induced vasodilatation in nine type 1 diabetic patients with autonomic neuropathy (AN+), defined by cardiovascular tests, as well as in 10 type 1 diabetic patients without autonomic neuropathy (AN-) and 10 healthy control subjects. Baseline myocardial perfusion index (K......The pathophysiological mechanisms responsible for increased cardiovascular mortality in diabetic autonomic neuropathy are unknown. To investigate the effect of autonomic neuropathy on myocardial function, we performed dynamic contrast-enhanced magnetic resonance perfusion imaging during baseline......(i)) was similar in the three groups (AN+ 88.6 +/- 8.7 ml. 100 g(-1). min(-1), AN- 82.6 +/- 7.2, control subjects 93.7 +/- 9.0) (means +/- SE). K(i) during Dipyridamole vasodilatation was significantly lower in the patients with autonomic neuropathy (P

  17. Update on myocardial perfusion imaging: role of regadenoson

    OpenAIRE

    Hendel, Robert

    2009-01-01

    Robert C HendelMidwest Heart Specialists, Central DuPage Hospital, Winfield, Illinois, USAAbstract: Pharmacologic stress myocardial perfusion imaging (MPI) is a noninvasive method for the evaluation of coronary artery disease in patients unable to exercise adequately. Commonly used pharmacologic stress agents (adenosine, dipyridamole, and dobutamine) have a high incidence of bothersome and potentially serious side-effects, several contraindications to testing, and require continuous infusion ...

  18. The efficacy of nisoldipine on myocardial perfusion in patients with silent myocardial ischemia

    Energy Technology Data Exchange (ETDEWEB)

    Yamazaki, Junichi; Muto, Hiroshi; Naitou, Katsutoshi [Toho University, Tokyo (Japan). Omori Hospital] [and others

    1997-06-01

    Patients who had old myocardial infarction associated with myocardial viability and ischemia were divided into a pain-free group and a pain-positive group of nine patients each. The improvement of myocardial perfusion with nisoldipine therapy was compared between the two groups using exercise-load Tl-201 myocardial SPECT (myocardial SPECT). The exercise time was significantly prolonged from 505 seconds to 607 seconds after administration of nisoldipine in the pain-positive group (p<0.05), but there was no change in the pain-free group. The extent score of the full circumference of the left ventricle, the severity score, and the %Tl uptake of the infarcted region were significantly improved in both groups by administration of nisoldipine. These findings suggested that nisoldipine caused a decrease in the myocardial oxygen requirements associated with reduction of the afterload and coronary artery dilatation in the pain-positive group, but mainly caused coronary dilatation in the pain-free group. Since myocardial perfusion also improved after nisoldipine administration in the pain-free group, the possibility that calcium antagonists can be used for prophylactic treatment of asymptomatic myocardial ischemia was suggested. (author)

  19. Acute myocardial infarction during regadenoson myocardial perfusion imaging.

    Science.gov (United States)

    Shah, Sachil; Parra, David; Rosenstein, Robert S

    2013-06-01

    Pharmacologic stress testing uses vasodilators to provide objective evidence of myocardial ischemia. Adenosine and dipyridamole are nonselective adenosine receptor agonists that have been associated with myocardial infarction (MI) during intravenous infusion. Mechanisms postulated for this effect include coronary steal, transmural steal, global hypotension, and direct vasoconstriction. Regadenoson, a direct A2A agonist, was approved for use in stress testing in 2008. We describe a 68-year-old man who presented to our institution with typical angina, relieved by nitroglycerin. He did not have electrocardiogram (ECG) changes suggestive of myocardial pathology, and laboratory testing did not reveal a significant rise in troponin-I levels. To further assess the etiology of his symptoms, he underwent a pharmacologic stress test with regadenoson followed by technetium 99 m sestamibi. Six minutes after regadenoson infusion, the patient developed severe retrosternal chest pain accompanied by ST elevations on ECG. Sublingual nitroglycerin was administered that resolved both the pain and ECG changes. The patient subsequently underwent urgent coronary angiography and was found to have a 95% critical stenosis involving the left anterior descending artery. We conclude this case represents a MI secondary to coronary steal phenomenon induced by regadenoson infusion. Clinicians should be aware this adverse effect can occur despite the improved side-effect profile of regadenoson. Continuous monitoring of vital signs and the ECG with regular assessment of symptoms is imperative to identify this rare but potentially devastating adverse event. © 2013 Pharmacotherapy Publications, Inc.

  20. Development of an Ex Vivo, Beating Heart Model for CT Myocardial Perfusion

    NARCIS (Netherlands)

    Pelgrim, Gert Jan; Das, Marco; Haberland, Ulrike; Slump, Cees; Handayani, Astri; van Tuijl, Sjoerd; Stijnen, Marco; Klotz, Ernst; Oudkerk, Matthijs; Wildberger, Joachim E.; Vliegenthart, Rozemarijn

    2015-01-01

    Objective. To test the feasibility of a CT-compatible, ex vivo, perfused porcine heart model for myocardial perfusion CT imaging. Methods. One porcine heart was perfused according to Langendorff. Dynamic perfusion scanning was performed with a second-generation dual source CT scanner. Circulatory

  1. Myocardial metabolic abnormalities in hypertrophic cardiomyopathy assessed by iodine-123-labeled beta-methyl-branched fatty acid myocardial scintigraphy and its relation to exercise-induced ischemia

    Energy Technology Data Exchange (ETDEWEB)

    Matsuo, Shinro; Nakamura, Yasuyuki; Takahashi, Masayuki; Mitsunami, Kenichi; Kinoshita, Masahiko [Shiga Univ. of Medical Science, Otsu (Japan)

    1998-03-01

    Reversible thallium-201 ({sup 201}Tl) abnormalities during exercise stress have been used as markers of myocardial ischemia in hypertrophic cardiomyopathy (HCM) and are most likely to identify relatively underperfused myocardium. Although metabolic abnormalities in HCM were reported, the relationship between impaired energy metabolism and exercise-induced ischemia has not been fully elucidated as yet. To assess the relationship between myocardial perfusion abnormalities and fatty acid metabolic abnormalities, 28 patients with HCM underwent exercise {sup 201}Tl and rest {sup 123}I-15-(p-iodophenyl)-3-methyl pentadecanoic acid (BMIPP) scintigraphy. Perfusion abnormalities were observed by exercise {sup 201}Tl in 19/28 patients with HCM. {sup 123}I-BMIPP uptake was decreased compared with delayed {sup 201}Tl in 106/364 (29%) of the total myocardial segments (p<0.01, McNemar symmetry test). Such disparity between {sup 123}I-BMIPP and {sup 201}Tl was observed more often in the 49/75 (65%) segments with reversible exercise {sup 201}Tl defects (p<0.001). Our results indicate that exercise-induced myocardial ischemia exists in HCM, resulting in metabolic abnormalities. The combination of {sup 123}I-BMIPP and {sup 201}Tl suggests that myocardial ischemia may play an important role in metabolic abnormalities in HCM. (author)

  2. Myocardial perfusion assessment with contrast echocardiography

    Science.gov (United States)

    Desco, Manuel; Ledesma-Carbayo, Maria J.; Santos, Andres; Garcia-Fernandez, Miguel A.; Marcos-Alberca, Pedro; Malpica, Norberto; Antoranz, Jose C.; Garcia-Barreno, Pedro

    2001-05-01

    Assessment of intramyocardial perfusion by contrast echocardiography is a promising new technique that allows to obtain quantitative parameters for the assessment of ischemic disease. In this work, a new methodology and a software prototype developed for this task are presented. It has been validated with Coherent Contrast Imaging (CCI) images acquired with an Acuson Sequoia scanner. Contrast (Optison microbubbles) is injected continuously during the scan. 150 images are acquired using low mechanical index U/S pulses. A burst of high mechanical index pulses is used to destroy bubbles, thus allowing to detect the contrast wash-in. The stud is performed in two conditions: rest and pharmacologically induced stress. The software developed allows to visualized the study (cine) and to select several ROIs within the heart wall. The position of these ROIs along the cardiac cycle is automatically corrected on the basis of the gradient field, and they can also be manually corrected in case the automatic procedure fails. Time curves are analyzed according to a parametric model that incorporates both contrast inflow rate and cyclic variations. Preliminary clinical results on 80 patients have allowed us to identify normal and pathological patterns and to establish the correlation of quantitative parameters with the real diagnosis.

  3. Comparison of Myocardial Perfusion Scintigraphy and Coronary Angiography Results

    Directory of Open Access Journals (Sweden)

    Umut Elboga

    2017-05-01

    Full Text Available Aim: Coronary artery disease (CAD is one of the most frequent causes of mortality and morbidity worldwide. Coronary angiography is the gold standard for the anatomical diagnosis of coronary artery stenosis. Myocardial Perfusion Scintigraphy (MPS is a non-invasive imaging modality used for the diagnosis of CAD. In this study, we aimed to compare the findings of MPS and coronary angiogram. Material and Method: Eighty-one patients (37 males, 44 females; mean age 55 ± 10.95 years with angina and detected perfusion defects on MPS were included in this study. All of the patients underwent coronary angiogram. A narrowing %u2265 50% was considered pathological on the coronary angiography. Results: Findings of the coronary angiogram and MPS were compared and found consistent in 51 (63% patients. A coronary narrowing < 50% was detected by coronary angiogram in 4 (5% of the remaining patients. Coronary angiogram was found to be normal in the remaining 26 patients (32% and these patients were evaluated as cardiac syndrome X (CSX known as microvascular angina (MA. Discussion: The findings showed that MPS is superior to coronary angiogram in the early diagnosis of myocardial perfusion disorders at the microvascular level. Therefore, we concluded that MPS should be the primary diagnostic tool to begin treatment before an anatomically large narrowing occurs in the coronaries.

  4. Myocardial perfusion imaging study of CO(2)-induced panic attack.

    Science.gov (United States)

    Soares-Filho, Gastão L F; Machado, Sergio; Arias-Carrión, Oscar; Santulli, Gaetano; Mesquita, Claudio T; Cosci, Fiammetta; Silva, Adriana C; Nardi, Antonio E

    2014-01-15

    Chest pain is often seen alongside with panic attacks. Moreover, panic disorder has been suggested as a risk factor for cardiovascular disease and even a trigger for acute coronary syndrome. Patients with coronary artery disease may have myocardial ischemia in response to mental stress, in which panic attack is a strong component, by an increase in coronary vasomotor tone or sympathetic hyperactivity setting off an increase in myocardial oxygen consumption. Indeed, coronary artery spasm was presumed to be present in cases of cardiac ischemia linked to panic disorder. These findings correlating panic disorder with coronary artery disease lead us to raise questions about the favorable prognosis of chest pain in panic attack. To investigate whether myocardial ischemia is the genesis of chest pain in panic attacks, we developed a myocardial perfusion study through research by myocardial scintigraphy in patients with panic attacks induced in the laboratory by inhalation of 35% carbon dioxide. In conclusion, from the data obtained, some hypotheses are discussed from the viewpoint of endothelial dysfunction and microvascular disease present in mental stress response. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Adenosine-stress dynamic myocardial perfusion imaging with second-generation dual-source CT: comparison with conventional catheter coronary angiography and SPECT nuclear myocardial perfusion imaging.

    Science.gov (United States)

    Wang, Yining; Qin, Ling; Shi, Ximin; Zeng, Yong; Jing, Hongli; Schoepf, U Joseph; Jin, Zhengyu

    2012-03-01

    The purpose of this article is to evaluate the feasibility of adenosine-stress dynamic myocardial perfusion imaging (MPI) with 128-MDCT dual-source CT for detecting myocardial ischemia in comparison with conventional catheter coronary angiography and nuclear MPI. Thirty patients (21 men and nine women; mean [± SD] age, 59.2 ± 7.6 years) prospectively underwent a combined stress CT perfusion and CT angiography (CTA) examination. Complete time-attenuation curves of the myocardium were acquired with prospectively ECG-triggered axial images at two alternating positions. Myocardial blood flow (MBF) was quantified according to dynamic CT perfusion, and MBF values of normal and abnormal segments were compared. Findings on CT perfusion were compared with those for stress and rest SPECT. Perfusion defects according to CT were correlated to flow-obstructing stenosis detected on CTA and catheter coronary angiography. On stress CT perfusion, 19 patients (63%) and 83 of 504 segments (16%) had perfusion abnormalities. There was a significant difference in MBF values between normal (142.9 ± 30.6 mL/100 mL/min) and hypoperfused (90.0 ± 22.8 mL/100 mL/min) segments (p stress CT perfusion detects myocardial perfusion defects in good correlation with nuclear MPI. CT perfusion combined with CTA improves the diagnostic accuracy for identifying flow-obstructing stenosis compared with CTA alone.

  6. Myocardial indium-111-antimyosin uptake in essential hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Uenlue, M.; Temiz, N.H. [Dept. of Nuclear Medicine, Dept. of Nuclear Medicine, Ankara (Turkey); Cengel, A. [Dept. of Cardiology, Gazi Univ. School of Medicine, Dept. of Nuclear Medicine, Ankara (Turkey)

    2003-06-01

    Aim: Evaluation of myocardial uptake of {sup 111}In-antimyosin antibodies in patients with essential hypertension for the verification of our hypothesis that it may increase in stage 1 in the left ventricle as a result of myocardial damage. Patients, methods: Twelve men (mean age: 59 {+-} 2.4 years) suffering from angina like symptoms and essential hypertension in clinical stage 1 according to the JNC-VI criteria were included into the study. These patients showed normal perfusion as revealed by thallium-201 myocardial study and coronary angiography. Left ventricular mass index was determined in echocardiography. Planar antimyosin images were obtained 48 h after the intravenous injection of the tracer. Heart to lung ratios were calculated as a parameter of myocardial tracer uptake using appropriate region of interests; values >1.52 were considered as abnormal. Results: We observed increased antimyosin uptake (mean: 1.71 {+-} 0.12) consistent with myocardial damage in 11 of 12 patients. Nine of 12 patients had a left ventricular hypertrophy with left ventricular mass index values (mean: 131 g/m{sup 2} {+-} 9.48) above 115 g/m{sup 2}. Heart to lung ratio was correlated significantly to left ventricular mass index (r = 0.902, p <0.001) and duration of hypertension (r = 0.948, p <0.001). Conclusion: Our results suggest that {sup 111}In-antimyosin imaging may indicate myocyte damage in early phases of hypertensive heart disease. (orig.)

  7. Comparison of glucose-insulin-thallium-201 infusion single photon emission computed tomography (SPECT), stress-redistribution-reinjection thallium-201 SPECT and low dose dobutamine echocardiography for prediction of reversible dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Sakamoto, Hiroki; Kondo, Makoto; Motohiro, Masayuki; Usami, Satoru [Shimada Municipal Hospital, Shizuoka (Japan)

    2001-12-01

    The usefulness of glucose-insulin-thallium-201 (GI-Tl) infusion single photon emission computed tomography (SPECT) in predicting reversible dysfunction has not been evaluated, so the present study recruited 20 patients with regional ischemic dysfunction for investigation. All patients underwent GI-Tl SPECT, post-stress Tl reinjection imaging and low dose dobutamine echocardiography. The diagnostic accuracy of these 3 techniques in predicting functional recovery was evaluated by receiver operating characteristic (ROC) analysis. In segments with functional recovery, regional Tl activities of GI-Tl SPECT were significantly higher than those of reinjection imaging (p<0.05), although there were no significant differences in segments without recovery. The area under the ROC curve for GI-Tl SPECT (0.75{+-}0.06) was greater than that for reinjection imaging (0.68{+-}0.07). The optimal cutoff values to identify viable myocardium were considered to be 55% of peak activity for GI-Tl SPECT and 50% for reinjection imaging. At this cutoff point, the sensitivity and specificity for detection of functional recovery were, respectively, 85% and 61% for GI-Tl SPECT, and 73% and 61% for reinjection imaging. Dobutamine echocardiography had the same sensitivity (85%), but lower specificity (48%) than GI-Tl SPECT. Continuous infusion of GI-Tl solution enhances regional Tl uptake compared with conventional post-stress reinjection imaging. This study suggests that GI-Tl SPECT is superior to reinjection imaging and dobutamine echocardiography in predicting functional recovery after ischemic left ventricular dysfunction. (author)

  8. Detection and dosimetry of gamma ray emitted from thallium-201 and technetium-99m based on chemiluminescence technique

    Energy Technology Data Exchange (ETDEWEB)

    Shourian, Mostafa [Laboratory of Microanalysis, Institute of Biochemistry and Biophysics, University of Tehran, P.O. Box 13145-1384, Tehran (Iran, Islamic Republic of); Tavakoli, Hassan, E-mail: tavakoli@ibb.ut.ac.i [Faculty of Medicine, Department of Physiology and Biophysics, Faculty of Medicine, Baqiyatollah University of Medical Sciences, P.O. Box 19395-6558, Tehran (Iran, Islamic Republic of); Ghourchian, Hedayatollah, E-mail: hadi@ibb.ut.ac.i [Laboratory of Microanalysis, Institute of Biochemistry and Biophysics, University of Tehran, P.O. Box 13145-1384, Tehran (Iran, Islamic Republic of); Rafiee-Pour, Hossain-Ali [Laboratory of Microanalysis, Institute of Biochemistry and Biophysics, University of Tehran, P.O. Box 13145-1384, Tehran (Iran, Islamic Republic of)

    2010-09-15

    This report describes the detection and dosimetry of gamma ray emitted from Thallium-201 ({sup 201}Tl) and Technetium-99m ({sup 99m}Tc) based on chemiluminescence technique. H{sub 2}O{sub 2} produced by two gamma emitter radioisotopes of {sup 201}Tl and {sup 99m}Tc were quantitatively measured by chemiluminescence method. Upon producing H{sub 2}O{sub 2} in a luminol alkaline solution, in the presence of diperiodatocuprate, as catalyst a chemical reaction was accrued and consequently the emitted light was measured. The determined H{sub 2}O{sub 2} concentration was correlated with the gamma ray detection and dosimetry. The sensitivity of chemiluminescence technique for {sup 201}Tl and {sup 99m}Tc dosimetry was determined to be 0.20 and 0.08 MBq/l (Mega Becquerel per liter) respectively (R.S.D. = %5, N = 3). The plotted calibration curves showed detection limits of 3.24 and 1.76 MBq/l for {sup 201}Tl and {sup 99m}Tc, respectively.

  9. Positron emission tomography myocardial perfusion imaging in children with suspected coronary abnormalities.

    Science.gov (United States)

    Singh, T P; Muzik, O; Forbes, T F; Di Carli, M F

    2003-01-01

    Positron emission tomography (PET) myocardial perfusion imaging has higher spatial resolution than conventional single photon emission computed tomography (SPECT) imaging and allows accurate and reproducible quantification of myocardial blood flow (MBF). In this article, we describe the role of PET myocardial perfusion imaging in clinical decision making in children with suspected coronary abnormalities. We performed a PET myocardial perfusion study using N-13 ammonia in 10 children (median age, 14 years; range, 1-17 years). The indications included exercise-induced chest pain and ST segment changes during exercise testing, coronary artery ectasia, hypertrophic cardiomyopathy with myocardial bridging of the left anterior descending coronary artery, and suspected left coronary stenosis in an infant with William's syndrome. MBF was assessed at baseline and during adenosine hyperemia in all 10 patients and postexercise in 8 patients. Myocardial perfusion was homogeneous at baseline in all 10 patients, during adenosine perfusion in 9 of 10 patients, and postexercise in all 8 patients. Three patients with homogeneous rest and stress perfusion had impaired myocardial flow reserve. The infant with William's syndrome developed a large, reversible perfusion defect in the left coronary territory during adenosine stress and underwent surgical repair. Myocardial flow reserve findings were valuable for clinical decision making in individual patients. We conclude that MBF quantification with N-13 ammonia and PET provides supplemental perfusion information and is helpful in clinical decision making in children with suspected coronary abnormalities.

  10. Myocardial perfusion imaging in patients with a recent, normal exercise test

    DEFF Research Database (Denmark)

    Bovin, Ann; Klausen, Ib Christian; Petersen, Lars Jelstrup

    2013-01-01

    To investigate the added value of myocardial perfusion scintigraphy imaging (MPI) in consecutive patients with suspected coronary artery disease (CAD) and a recent, normal exercise electrocardiography (ECG).......To investigate the added value of myocardial perfusion scintigraphy imaging (MPI) in consecutive patients with suspected coronary artery disease (CAD) and a recent, normal exercise electrocardiography (ECG)....

  11. Comparison of non-attenuation corrected and attenuation corrected myocardial perfusion SPE

    Directory of Open Access Journals (Sweden)

    Hasan Raza

    2016-09-01

    Conclusion: This study demonstrates that CT based attenuation corrected Tc-99mm sestamibi SPECT myocardial perfusion imaging significantly improved the specificity of the RCA territory compared with non-attenuation corrected Tc-99mm sestamibi SPECT myocardial perfusion imaging in both genders irrespective of BMI.

  12. PET detection of viable tissue in myocardial segments with persistent defects at T1-201 SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Brunken, R.C.; Kottou, S.; Nienaber, C.A.; Schwaiger, M.; Ratib, O.M.; Phelps, M.E.; Schelbert, H.R.

    1989-07-01

    To assess myocardial glucose metabolism and perfusion in 142 myocardial segments with defects seen at thallium-201 single photon emission computed tomography (SPECT), 27 studies with positron emission tomography (PET) utilizing nitrogen-13 ammonia and fluorine-18 deoxyglucose were performed in 26 patients. Myocardial infarction was defined on the basis of concordant reductions in segmental perfusion and glucose utilization; myocardial ischemia, on the basis of preservation of glucose utilization (metabolic viability) in segments with hypoperfusion at rest. Of the 142 segments analyzed, 101 had fixed defects, 31 had partially reversible defects, and ten had completely reversible defects. Preserved glucose utilization was identified in 47 (46.5%) of the segments with fixed defects and 20 (64.5%) of the segments with partially reversible defects. Of the ten segments with completely reversible defects, five (50%) were normal, and five (50%) exhibited ischemia at PET. Visual improvement in a persistent thallium defect at delayed imaging was not associated with residual glucose metabolic activity. Thus, PET can be used to detect glucose metabolic activity in a significant proportion of myocardial segments with fixed or partially redistributing defects seen at thallium SPECT, which suggests that the extent of tissue viability in patients with ischemic heart disease is underestimated at thallium scintigraphy.

  13. Update on myocardial perfusion imaging: role of regadenoson

    Directory of Open Access Journals (Sweden)

    Robert C Hendel

    2009-02-01

    Full Text Available Robert C HendelMidwest Heart Specialists, Central DuPage Hospital, Winfield, Illinois, USAAbstract: Pharmacologic stress myocardial perfusion imaging (MPI is a noninvasive method for the evaluation of coronary artery disease in patients unable to exercise adequately. Commonly used pharmacologic stress agents (adenosine, dipyridamole, and dobutamine have a high incidence of bothersome and potentially serious side-effects, several contraindications to testing, and require continuous infusion with weight-adjusted doses. Newer agents are, therefore, needed. Selective activation of A2A adenosine receptors on the coronary vasculature should provide coronary vasodilation for MPI with fewer or less severe side-effects associated with nonspecific agonists, such as adenosine and dipyridamole. Regadenoson is the first selective A2A receptor agonist to be approved as a pharmacologic stress agent for use with radionuclide MPI. Regadenoson is administered at a standard, fixed dose of 400 μg from a prefilled syringe or single-use vial by intravenous injection over 10 seconds. In clinical trials, regadenoson provided good quality images yielding accurate diagnostic information, and was safe and well tolerated. No infusion pump is required and the stress protocol is brief. Further studies are now required to evaluate regadenoson as a stress agent in combination with low-level exercise, with prior caffeine intake, and in patients with asthma or chronic obstructive pulmonary disease.Keywords: myocardial perfusion imaging, pharmacologic stress, A2A receptor agonist, regadenoson, ischemic heart disease, SPECT, diagnosis

  14. Sequential dual-isotope SPECT imaging with thallium-201 and technetium-99m-sestamibi.

    Science.gov (United States)

    Heo, J; Wolmer, I; Kegel, J; Iskandrian, A S

    1994-04-01

    This study examined the results of sequential SPECT dual-isotope imaging with 201Tl and 99mTc-sestamibi in 148 patients, 114 of whom also had coronary angiography and 34 had exercise testing or adenosine infusion at a rate of 140 micrograms/kg/min for 6 min. The study was completed within 2 hr. The stress and rest images were normal in 11 of 17 patients (65%) with no CAD by angiography and in 33 of 34 patients with a low pretest probability of CAD (normalcy rate = 97%). The images were abnormal in 75 patients with CAD (77%). The perfusion pattern was compared to wall motion in 485 segments (97 patients) assessed by contrast ventriculography. There were no or reversible perfusion defects in 357 of 386 segments (92%) with no wall motion abnormality. Sequential dual-isotope imaging is feasible and can be completed in a short period of time and may therefore enhance laboratory throughput and patient convenience.

  15. Validation of myocardial perfusion quantification by dynamic CT in an ex-vivo porcine heart model

    NARCIS (Netherlands)

    Pelgrim, Gert Jan; Das, Marco; van Tuijl, Sjoerd; van Assen, Marly; Prinzen, Frits W; Stijnen, Marco; Oudkerk, Matthijs; Wildberger, Joachim E; Vliegenthart, Rozemarijn

    2017-01-01

    To test the accuracy of quantification of myocardial perfusion imaging (MPI) using computed tomography (CT) in ex-vivo porcine models. Five isolated porcine hearts were perfused according to Langendorff. Hearts were perfused using retrograde flow through the aorta and blood flow, blood pressure and

  16. Quantification of MRI measured myocardial perfusion reserve in healthy humans: a comparison with positron emission tomography

    DEFF Research Database (Denmark)

    Fritz-Hansen, Thomas; Hove, Jens D; Kofoed, Klaus F

    2008-01-01

    PURPOSE: To validate a noninvasive quantitative MRI technique, the K(i) perfusion method, for myocardial perfusion in humans using (13)N-ammonia PET as a reference method. MATERIALS AND METHODS: Ten healthy males (64 +/- 8 years) were examined with combined PET and MRI perfusion imaging at rest a...

  17. Influence of revascularization on myocardial perfusion, metabolism and function

    Energy Technology Data Exchange (ETDEWEB)

    Kropp, Joachim; Krois, Markus; Eichhorn, Bernd; Fehske, Wolfgang; Likungu, James; Kirchhoff, P.G.; Luederitz, Berndt; Biersack, Hans-Juergen [Bonn Univ. (Germany); Knapp, F.F. Jr.

    1993-12-01

    Thirty-nine patients with coronary artery disease (CAD) were investigated with sequential SPECT-scintigraphy after administration of 200 MBq of 15-(p-[I-123]iodophenyl)pentadecanoic acid (IPPA) at peak submaximal exercise. Twenty patients underwent coronary angioplasty (PTCA) from which 14 had control coronary arteriography (CA) and left ventricular cineventriculography (LVCV). Nineteen patients underwent bypass graft surgery (ACB) and stress sonography. Semi-quantification of uptake (Up, related to perfusion) and turnover (Tr, linked to metabolism) was obtained by segmental comparison of oblique slices. About 90% of the reperfused myocardial segments in the PTCA-group and 76% in the ACB-group showed an improvement of uptake after therapy (RUp). Out of these, 50% and 66% exhibited increased turnover (RTr) after PTCA or ACB, respectively. The remaining segments had persistingly pathologic RTr indicating a dissociation of improvement of perfusion and metabolism after therapy. Pathologic RTr was highly correlated with regional wall motion abnormalities (RWMA) after therapy in both groups. In the ACB-group improvement in RTr was correlated with improved RWM at rest and stress in 86% and 92%, respectively, whereas no improvement in RTr was correlated with impared function in 100% and 52%, respectively. IPPA-studies show potential to provide information about changes of perfusion and metabolism after reperfusion and IPPA-turnover is a good predictor of the pattern of contractile function. (author).

  18. Myocardial perfusion single photon emission computed tomography in asymptomatic diabetics.

    Science.gov (United States)

    Harshad, K; Sathyamurthy, I; Ashish, G; Padma, D; Shelley, S; Indirani, M; Subramanian, K

    2010-01-01

    Coronary artery disease (CAD) is the most important cause of mortality in diabetic patients. Diabetes mellitus (DM) due to autonomic neuropathy leads to asymptomatic CAD. Hence, it is important to screen the patients with DM for CAD. To study the prevalence of asymptomatic CAD by Myocardial Perfuision SPECT (Single Photon Emission Computed Tomography) (MPS) in diabetics. This prospective study included 88 asymptomatic patients (58 males and 30 females) of Type 2 DM of more than 5 years duration in the age group of 40-65 years. Risk factors like hypertension, dyslipidemia, smoking, family history of CAD and Body Mass Index > or = 25 kg/sq.m were assessed. All these patients underwent MPS study as two day standard protocol. Thirty eight patients underwent invasive Coronary Angiography (CAG) and stenosis greater than 50% was considered significant. Abnormal perfusion was detected in 38 (43%) diabetics and 4 (11%) controls. A total of 81 perfusion defects were identified (19 fired and 62 reversible). CAG showed significant coronary stenosis in 26 (68.4%), insignificant in 8 (21%) and no stenosis in 4 (10.6%) patients. A total of 114 coronaries were analysed, significant stenosis in 67 (58.8%) coronaries, 21 (18.4%) had insignificant lesions and 26(22.8%) were normal. In comparison to CAG, MPS had sensitivity of 86.6% and specificity of 51%. The Myocardial Perfusion SPECT is a sensitive diagnostic tool to identify ischemia in asymptomatic diabetics. MPS can be used as screening test for risk stratification. It has a prognostic value in predicting the outcome of CAD and can be useful for long-term follow up too.

  19. The prognostic value of regadenoson myocardial perfusion imaging.

    Science.gov (United States)

    Hage, Fadi G; Ghimire, Gopal; Lester, Davis; Mckay, Joshua; Bleich, Steven; El-Hajj, Stephanie; Iskandrian, Ami E

    2015-12-01

    Regadenoson (REGA), a selective adenosine A2A receptor agonist, is the most widely used stress agent for SPECT myocardial perfusion imaging (MPI) in the United States. The diagnostic accuracy of REGA MPI is comparable to Adenosine MPI, but its prognostic value is not well defined. We categorized 1,400 patients (700 consecutive normal and 700 consecutive abnormal REGA-MPIs) into 4 groups based on the perfusion defect size using automated quantitative analysis: Group 1: normal perfusion; Group 2: 20%. The primary outcome was a composite of cardiac death, myocardial infarction (MI), and late coronary revascularization (CR >90 days after MPI). Of the 1,400 patients (42% male, 37% diabetes, 21% heart failure, 26% end-stage renal disease), the primary outcome occurred in 23% (17% cardiac death, 4% MI, 6% late CR) during 46 ± 18 months of follow-up and 8% had early CR (within 90 days of MPI). Early CR occurred in 0.4%, 9%, 17%, and 17% and the primary outcome in 10%, 27%, 31%, and 43% in Groups 1-4, respectively (P < .001 for both). In an adjusted Cox proportional model, the hazard ratio for the primary outcome was 2.68 (1.77-4.06), 3.32 (2.28-4.83), and 4.05 (2.78-5.91) for Groups 2-4 compared to Group 1. REGA MPI provides powerful prognostic information that has important implications in patient management and can guide clinical practice.

  20. Aid in the detection of myocardial perfusion abnormality utilizing SPECT atlas and images registration: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Padua, Rodrigo Donizete Santana de [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Div. de Cardiologia]. E-mail: rodrigo_dsp@hcrp.fmrp.usp.br; Oliveira, Lucas Ferrari de [Universidade Federal de Pelotas (UFPel), RS (Brazil). Inst. de Fisica e Matematica. Dept. de Tecnologia da Informacao; Marques, Paulo Mazzoncini de Azevedo [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Centro de Ciencias das Imagens e Fisica Medica; Groote, Jean-Jacques Georges Soares de [Instituto de Ensino Superior COC, Ribeirao Preto, SP (Brazil). Lab. of Artifical Intelligence and Applications; Castro, Adelson Antonio de [Universidade de Sao Paulo (USP), Ribeirao Preto, SP, (Brazil). Faculdade de Medicina; Ana, Lauro Wichert [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Centro de Ciencias das Imagens e Fisica Medica; Simoes, Marcus Vinicius [Universidade de Sao Paulo (USP), Ribeirao Preto, SP, (Brazil). Faculdade de Medicina. Divisao de Cardiologia

    2008-11-15

    To develop an atlas of myocardial perfusion scintigraphy and evaluating its applicability in computer-aided detection of myocardial perfusion defects in patients with ischemic heart disease. The atlas was created with rest-stress myocardial perfusion scintigraphic images of 20 patients of both genders with low probability of coronary artery disease and considered as normal by two experienced observers. Techniques of image registration and mathematical operations on images were utilized for obtaining template images depicting mean myocardial uptake and standard deviation for each gender and physiological condition. Myocardial perfusion scintigraphy images of one male and one female patient were aligned with the corresponding atlas template image, and voxels with myocardial uptake rates two standard deviations below the mean voxel value of the respective region in the atlas template image were highlighted on the tomographic sections and confirmed as perfusion defects by both observe. The present study demonstrated the creation of an atlas of myocardial perfusion scintigraphy with promising results of this tool as an aid in the detection of myocardial perfusion defects. However, further prospective validation with a more representative sample is recommended. (author)

  1. Diagnostic value of 123I-phenylpentadecanoic acid (IPPA) metabolic and thallium 201 perfusion imaging in stable coronary artery disease.

    Science.gov (United States)

    Walamies, M; Turjanmaa, V; Koskinen, M; Uusitalo, A

    1993-08-01

    The diagnostic value of 123I-phenylpentadecanoic acid (IPPA) metabolic cardiac imaging was studied in a group (n = 29) of patients with angiographically confirmed CAD using single photon emission computed tomography (SPECT). A symptom-limited exercise test was first done with IPPA, and 2 days later with thallium. Medications were not withheld during testing. Fourteen healthy control subjects participated in parallel IPPA and 15 in thallium tests. Data acquisition and output were comparable in the two imaging modalities. By testing various relatively simple criteria for abnormality we found that the semiquantitative interpretation was more accurate than the visual readings. The best compromise of accuracy with the scored criteria consisted of a sensitivity of 86% and a specificity of 86%, obtained with IPPA polar tomograms (mild exercise defect) and a sensitivity of 86% and a specificity of 80% obtained with thallium (regionally decreased washout). With visual interpretation alone, a sensitivity of 83% and a specificity of 71% was detected with IPPA (mild exercise defect) and 72% and 73%, respectively, with thallium (partial reversibility). The sensitivity of the exercise ECG alone was 62%. The results of this study imply that IPPA imaging could be a rational, uncomplicated clinical method for non-invasive diagnosis of CAD. The diagnostic ability of IPPA is at least as good as that of thallium, and it is possible to use them in succession.

  2. Patterns of myocardial perfusion in humans evaluated with contrast-enhanced 320 multidetector computed tomography

    DEFF Research Database (Denmark)

    Kühl, J Tobias; Linde, Jesper J; Fuchs, Andreas

    2012-01-01

    of intravenous adenosine infusion on regional myocardial perfusion. To evaluate myocardial perfusion patterns at rest, we scanned 14 healthy subjects with PET and 14 age and gender matched subjects with 320 MDCT. To evaluate the effect of adenosine stress on relative perfusion patterns 14 subjects with near......-normal epicardial coronary arteries were studied at rest and during adenosine stress. Relative perfusion was assessed as attenuation density (AD) in 16 segments of the LV, and each segment was divided into 3 layers: endo-, mid- and epi-cardial. During rest the relative AD by MDCT was lower in the lateral wall...

  3. The ECG component of Thallium-201 exercise testing impacts on cardiac intervention rates

    Energy Technology Data Exchange (ETDEWEB)

    Deague, J.; Salehi, N.; Grigg, L.; Lichtenstein, M.; Better, N. [Royal Melbourne Hospital, Parkville, VIC (Australia). Departments of Nuclear Medicine and Cardiology

    1998-06-01

    Full text: Thallium exercise testing (Tlex) offers superior sensitivity and specificity to exercise electrocardiography (ECG), but the value of the ECG data in Tlex remains poorly studied. While a normal Tlex is associated with an excellent prognosis, patients with a positive Tlex have a higher cardiac event rate. We aimed to see if a negative ECG Component of the Tlex (ECGTl) was associated with an improved outcome compared with a positive ECGTl, in those patients with a reversible Tlex defect. We followed 100 consecutive patients retrospectively with a reversible defect on Tlex (50 with negative and 50 with positive ECGTI) for 12 months. The ECG was reviewed as positive (1mm ST depression 0.08 seconds after J point or >2mm if on digoxin or prior ECG changes), negative, equivocal or uninterpretable. We excluded patients with pharmacological testing, and those with equivocal or uninterpretable ECGs. End-points included angiography, cardiac interventions and cardiac event rate (CER) incorporating unstable angina, acute myocardial infarction, and cardiac death. In conclusion 24% of patients with reversible defects on Tlex who had a negative ECGTI still proceeded to PTCA or CABG. Those with a positive ECGTI had a higher incidence of angiography and cardiac revascularisation, but this difference was only evident in patients with mild to moderate reversibility

  4. Dual-tracer autoradiography with thallium-201 and iodine-125 MIBG in BIO 14. 6 cardiomyopathic Syrian hamsters

    Energy Technology Data Exchange (ETDEWEB)

    Taguchi, Takahisa; Kobayashi, Akira; Kurata, Chinori; Tawarahara, Kei; Yamazaki, Noboru (Hamamatsu Univ. School of Medicine, Shizuoka (Japan))

    1993-11-01

    Dual-tracer imaging of the heart with [sup 125]I-metaiodobenzylguanidine (MIBG) and [sup 201]Tl can simultaneously demonstrate the distribution of sympathetic nerve endings and the underlying myocardial perfusion. A quantitative dual-tracer autoradiographic study with [sup 201]Tl and [sup 125]I-MIBG was performed to investigate changes in the distribution of cardiac sympathetic innervation with the progression of cardiomyopathy in BIO 14.6 hamsters. The distribution of [sup 201]Tl was uniform in control hamsters and BIO 14.6 hamsters at all stages of cardiomyopathy. In contrast, a reduction in MIBG accumulation occurred in the endocardial region of the left ventricular free wall and the left ventricular aspect of the interventricular septum in BIO 14.6 hamsters at 3 and 8 months of age. Thus, there was an uncoupling of the left ventricular distribution of [sup 201]Tl and [sup 125]I-MIBG in BIO 14.6 hamsters. In addition, interstitial fibrosis was increased in the interventricular septum, the subendocardial region of the left ventricular free wall, and the right ventricular wall, which were the sites of reduced MIBG accumulation. This study shows that dual myocardial imaging with MIBG and [sup 201]Tl may be useful for investigating patients with cardiomyopathy. (author).

  5. Prognostic value of dobutamine-atropine stress myocardial perfusion imaging in patients with diabetes

    NARCIS (Netherlands)

    A.F.L. Schinkel (Arend); A. Elhendy (Abdou); J.J. Bax (Jeroen); E.C. Vourvouri (Eleni); F. Sozzi (Fabiola); R. Valkema (Roelf); D. Poldermans (Don); J.R.T.C. Roelandt (Jos); R.T. van Domburg (Ron)

    2002-01-01

    textabstractOBJECTIVE: Exercise tolerance in patients with diabetes is frequently impaired due to noncardiac disease such as claudication and polyneuropathy. This study assesses the prognostic value of dobutamine stress myocardial perfusion imaging in patients with diabetes.

  6. A decision support system for stress only myocardial perfusion scintigraphy may save unnecessary rest studies

    DEFF Research Database (Denmark)

    Tägil, K; Jakobsson, D; Lomsky, M

    2013-01-01

    The aim of this study was to investigate the influence of a computer-based decision support system (DSS) on performance and inter-observer variability of interpretations regarding ischaemia and infarction in myocardial perfusion scintigraphy (MPS)....

  7. EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology

    NARCIS (Netherlands)

    Hesse, B.; Tägil, K.; Cuocolo, A.; Anagnostopoulos, C.; Bardiés, M.; Bax, J.; Bengel, F.; Busemann Sokole, E.; Davies, G.; Dondi, M.; Edenbrandt, L.; Franken, P.; Kjaer, A.; Knuuti, J.; Lassmann, M.; Ljungberg, M.; Marcassa, C.; Marie, P. Y.; McKiddie, F.; O'Connor, M.; Prvulovich, E.; Underwood, R.; van Eck-Smit, B.

    2005-01-01

    The European procedural guidelines for radionuclide imaging of myocardial perfusion and viability are presented in 13 sections covering patient information, radiopharmaceuticals, injected activities and dosimetry, stress tests, imaging protocols and acquisition, quality control and reconstruction

  8. A Unifying model of perfusion and motion applied to reconstruction of sparsely sampled free-breathing myocardial perfusion MRI

    DEFF Research Database (Denmark)

    Pedersen, Henrik; Ólafsdóttir, Hildur; Larsen, Rasmus

    2010-01-01

    The clinical potential of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is currently limited by respiratory induced motion of the heart. This paper presents a unifying model of perfusion and motion in which respiratory motion becomes an integral part of myocardial perfusion...... quantification. Hence, the need for tedious manual motion correction prior to perfusion quantification is avoided. In addition, we demonstrate that the proposed framework facilitates the process of reconstructing DCEMRI from sparsely sampled data in the presence of respiratory motion. The paper focuses primarily...... on the underlying theory of the proposed framework, but shows in vivo results of respiratory motion correction and simulation results of reconstructing sparsely sampled data....

  9. Perfusion vector - a new method to quantify myocardial perfusion scintigraphy images: a simulation study with validation in patients

    DEFF Research Database (Denmark)

    Minarik, David; Senneby, Martin; Wollmer, Per

    2015-01-01

    Background The interpretation of myocardial perfusion scintigraphy (MPS) largely relies on visual assessment by the physician of the localization and extent of a perfusion defect. The aim of this study was to introduce the concept of the perfusion vector as a new objective quantitative method...... for further assisting the visual interpretation and to test the concept using simulated MPS images as well as patients. Methods The perfusion vector is based on calculating the difference between the anatomical centroid and the perfusion center of gravity of the left ventricle. Simulated MPS images were.......001) but not for patients with infarction. The correlation between the defect size and stress vector magnitude was also found to be significant (p assisting the visual interpretation in MPS studies. Further...

  10. Analysis of myocardial perfusion parameters in an ex-vivo porcine heart model using third generation dual-source CT

    NARCIS (Netherlands)

    Pelgrim, Gert Jan; Duguay, Taylor M; Stijnen, J Marco A; Varga-Szemes, Akos; Van Tuijl, Sjoerd; Schoepf, U Joseph; Oudkerk, Matthijs; Vliegenthart, Rozemarijn

    2017-01-01

    PURPOSE: To evaluate the relationship between fractional flow reserve (FFR)-determined coronary artery stenosis severity and myocardial perfusion parameters derived from dynamic myocardial CT perfusion imaging (CTP) in an ex-vivo porcine heart model. METHODS: Six porcine hearts were perfused

  11. Development of coronary vasospasm during adenosine-stress myocardial perfusion CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Jeong Gu; Choi, Seong Hoon; Kang, Byeong Seong; Bang, Min Aeo; Kwon, Woon Jeong [Dept. of Radiology, Ulsan University Hospital, University of Ulsan College of Medicine, Ulsan (Korea, Republic of)

    2015-06-15

    Adenosine is a short-acting coronary vasodilator, and it is widely used during pharmacological stress myocardial perfusion imaging. It has a well-established safety profile, and most of its side effects are known to be mild and transient. Until now, coronary vasospasm has been rarely reported as a side effect of adenosine during or after adenosine stress test. This study reports a case of coronary vasospasm which was documented on stress myocardial perfusion CT imaging during adenosine stress test.

  12. Subendocardial versus transmural ischaemia in myocardial perfusion SPECT--a Monte Carlo study

    DEFF Research Database (Denmark)

    Bartosik, Jolanta; El-Ali, Henrik Hussein; Nilsson, Ulf

    2006-01-01

    Myocardial perfusion imaging with single-photon emission computed tomography (SPECT) is useful for the evaluation of patients with known or suspected coronary artery disease. Parameters of interest are the reduction in the blood perfusion (severity) and the lesion volume (extent). The aim of this...

  13. Clinical investigation of large perfusion defect cases with {sup 201}Tl exercise myocardial scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Morota, Motoi; Kobayashi, Yasuhiko [Tokyo Medical Coll. (Japan)

    1999-02-01

    We investigated retrospectively the clinical significance of large perfusion defect on {sup 201}Thallium myocardial scintigraphy from the records of 833 patients during the past 3 years from 1991 to 1994. The patients were divided into 3 groups according to the extent of perfusion defect; cases with normal perfusion (n=561), with small perfusion defect (n=211) and with large perfusion defect (n=61). We found that the proportions of cases with large perfusion defect was significantly larger than that of cases with small perfusion defect in myocardial disease (MD; hypertrophic cardiomyopathy, dilated cardiomyopathy, and post myocarditis combined) (P<0.001). Analyzing patients with ischemic heart disease (IHD; angina pectoris and myocardial infarction) according to the severity of coronary artery lesion, the proportion of cases with large perfusion defect was significantly larger than that of cases with small perfusion defect in 3 vessel disease (P<0.001). Incidence of diabetes mellitus was significantly higher in patients with IHD than in those with MD in large perfusion defect group (P<0.01). As for symptoms in large perfusion defect group, the incidences of chest pain, chest oppression, and chest discomfort were significantly higher in patients with IHD than in those with MD (P<0.001), whereas the incidences of palpitation and shortness of breath were significantly higher in patients with MD (P<0.001). These results suggest that IHD with multiple artery lesions and MD underlie large perfusion defect on {sup 201}Thallium myocardial scintigraphy and that complication of diabetes mellitus and clinical symptoms may be useful in differentiating IHD from MD. (author)

  14. Effect of nicorandil on the myocardial tissue perfusion and myocardial cell injury in patients with diabetes after PCI

    Directory of Open Access Journals (Sweden)

    Xue-Li Ren1

    2017-04-01

    Full Text Available Objective: To study the effect of nicorandil on the myocardial tissue perfusion and myocardial cell damage in patients with diabetes after percutaneous coronary intervention (PCI. Methods: 68 patients with coronary heart disease and type 2 diabetes mellitus who received PCI in our hospital between May 2011 and September 2015 were collected and then divided into observation group and control group (n=34 according to the single-blind randomized control method. Control group of patients received PCI alone, and the observation group of patients received nicorandil therapy after PCI. After treatment, real-time myocardial ultrasound contrast was used to evaluate the myocardial perfusion of two groups of patients; blood biochemical analyzer was used to detect the contents of peripheral blood myocardial enzyme spectrum indexes; the ELISA method was used to detect the contents of serum oxidative stress indicators; RIA method was used to detect the contents of serum apoptosis molecules. Results: After treatment, the myocardial tissue perfusion parameters plateau peak intensity (A, slope rate of curve (β and myocardial blood flow (A×β levels of observation group were significantly higher than those of control group (P<0.05; peripheral blood myocardial enzyme spectrum indexes creatine kinase (CK, lactate dehydrogenase (LDH, troponin I (cTnI and glutamic oxalacetic transaminase (GOT contents of observation group were significantly lower than those of control group (P<0.05; serum vitamin E (VitE and vitamin C (VitC contents of observation group were significantly higher than those of control group while malondialdehyde (MDA, advanced oxidation protein products (AOPPs, soluble apoptosis-associated factor (sFas and soluble apoptosis-associated factor ligand (sFasL contents were lower than those of control group (P<0.05. Conclusion: Adjuvant nicorandil therapy can improve the myocardial perfusion and reduce the myocardial cell injury in patients with coronary

  15. Influence of the arm position in myocardial perfusion imaging acquisition

    Directory of Open Access Journals (Sweden)

    Marisa Izaki

    2014-07-01

    Full Text Available Objective: despite the technologic advances in myocardial perfusion imaging, we keep using an uncomfortable and sometimes impracticable patient position - supine with arms raised above the head (U. The purpose of this study was to investigate whether perfusion and functional cardiac gated SPECT scan results of acquisition U are equivalent to another position modality: supine with arms down at the sides of the trunk (D. Methods and Results: we performed U acquisition and in sequence D acquisition in 120 patients (pts using a one-day MPI (rest-gated/stress, with 99mTc-sestamibi (370 MBq and 1110 MBq. Images were processed by the iterative reconstruction method (OSEM. Rest (R and stress (S studies were scored using 17-segments model. Functional parameters (left ventricular ejection fraction, and volumes were automatically obtained by the quantitative gated SPECT (QGS program. According to the degree of stress defects observed in U study, the patients were categorized in two subgroups: normal (SSS ≤ 3 or 3 or ≥ 5%. Shoulder/back pain occurred in 23.3% of U patients and in 5% of D. No significant differences between U and D were found for SSS (p = 0.82 and SRS (p = 0.74 in normal group. In abnormal group, good correlation was found between U and D modes for SSS (Rho = 0.95, p = 0.0001 and SRS (Rho = 0.96 p = 0.0001, but the mean SSS (12.53 ± 7.54 and SRS (10.60 ± 7.08 values of D were significantly lower (p < 0.05 than SSS (13.43 ± 6.81 and SRS (11.33 ± 6.97 of U mode. Function measurements presented good correlations, except for end-diastolic volume (p = 0.0001. Conclusion: although D mode appears to be more comfortable and presented a good correlation with U values of SSS and SRS, in abnormal pts, the extent and severity of defects can be underestimated. Considering clinical implications of an accurate perfusion measurement, the acquisition with the arms down should be avoided.

  16. Adenosine-stress dynamic real-time myocardial perfusion CT and adenosine-stress first-pass dual-energy myocardial perfusion CT for the assessment of acute chest pain: Initial results

    Energy Technology Data Exchange (ETDEWEB)

    Weininger, Markus [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Department of Medicine, Division of Cardiology, Medical University of South Carolina, Charleston, SC (United States); Ramachandra, Ashok [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Fink, Christian [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University (Germany); Rowe, Garrett W.; Costello, Philip [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Henzler, Thomas [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University (Germany)

    2012-12-15

    Purpose: Recent innovations in CT enable the evolution from mere morphologic imaging to dynamic and functional testing. We describe our initial experience performing myocardial stress perfusion CT in a clinical population with acute chest pain. Methods and materials: Myocardial stress perfusion CT was performed on twenty consecutive patients (15 men, 5 women; mean age 65 ± 8 years) who presented with acute chest pain and were clinically referred for stress/rest SPECT and cardiac MRI. Prior to CT each patient was randomly assigned either to Group A or to Group B in a consecutive order (10 patients per group). Group A underwent adenosine-stress dynamic real-time myocardial perfusion CT using a novel “shuttle” mode on a 2nd generation dual-source CT. Group B underwent adenosine-stress first-pass dual-energy myocardial perfusion CT using the same CT scanner in dual-energy mode. Two experienced observers visually analyzed all CT perfusion studies. CT findings were compared with MRI and SPECT. Results: In Group A 149/170 myocardial segments (88%) could be evaluated. Real-time perfusion CT (versus SPECT) had 86% (84%) sensitivity, 98% (92%) specificity, 94% (88%) positive predictive value, and 96% (92%) negative predictive value in comparison with perfusion MRI for the detection of myocardial perfusion defects. In Group B all myocardial segments were available for analysis. Compared with MRI, dual-energy myocardial perfusion CT (versus SPECT) had 93% (94%) sensitivity, 99% (98%) specificity, 92% (88%) positive predictive value, and 96% (94%) negative predictive value for detecting hypoperfused myocardial segments. Conclusion: Our results suggest the clinical feasibility of myocardial perfusion CT imaging in patients with acute chest pain. Compared to MRI and SPECT both, dynamic real-time perfusion CT and first-pass dual-energy perfusion CT showed good agreement for the detection of myocardial perfusion defects.

  17. Dobutamine stress radionuclide ventriculography reveals silent myocardial dysfunction in Kawasaki disease

    Energy Technology Data Exchange (ETDEWEB)

    Hamamichi, Yuji; Ichida, Fukiko; Tsubata, Shinichi [Toyama Medical and Pharmaceutical Univ., Sugitani (Japan). Faculty of Medicine] (and others)

    2002-01-01

    Dobutamine (DOB) stress radionuclide ventriculography (RVG) is proposed for evaluating left ventricular performance in patients with Kawasaki disease (KD). Dobutamine stress RVG, up to 15{mu}g{center_dot}kg{sup -1}{center_dot}min{sup -1}, was performed in 40 patients with a history of KD, some of whom had a perfusion defect (PD group) on dipyridamole stress thallium-201 myocardial imaging, some of whom had no perfusion defects (NPD group), and some of whom had no coronary artery lesions (C group). No significant differences in either systolic or diastolic indices of the left ventricle at rest were observed between the 3 groups. Although hemodynamic responses were similar in all patients after DOB stress, early diastolic index of the first third filling fraction decreased only in the PD group and was significantly lower in this group compared with the C group (p<0.01). The asynchrony index increased significantly in those patients with coronary stenosis after DOB stress (p<0.05). No serious side-effects were observed during the study. Even late after onset, patients with myocardial ischemia as a result of KD still had impaired early diastolic filling and asynchronous relaxation of the left ventricle. As an alternative to exercise testing, DOB stress RVG is a safe and promising means for serially evaluating left ventricular performance in patients with KD. (author)

  18. Added value of attenuation-corrected myocardial perfusion scintigraphy in a patient with dextrocardia

    NARCIS (Netherlands)

    Slart, RHJA; De Boer, J; Jager, PL; Piers, DA

    2002-01-01

    A 52-year-old woman with dextrocardia was evaluated for chest pain. To exclude myocardial ischemia, she underwent a 2-day rest and bicycle stress myocardial perfusion study with 600 MBq (16 mCi) Tc-99m sestamibi. The rotational direction of the perpendicularly positioned camera heads was fixed and

  19. Applicability of the Appropriate use Criteria for Myocardial Perfusion Scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Anderson de [Universidade Federal Fluminense - UFF, Niterói, RJ (Brazil); Comissão Nacional de Energia Nuclear - CNEN (Brazil); Rezende, Maria Fernanda [Universidade Federal Fluminense - UFF, Niterói, RJ (Brazil); Hospital Pró-Cardíaco, Rio de Janeiro, RJ (Brazil); Corrêa, Renato; Mousinho, Rodrigo [Hospital Pró-Cardíaco, Rio de Janeiro, RJ (Brazil); Azevedo, Jader Cunha [Universidade Federal Fluminense - UFF, Niterói, RJ (Brazil); Hospital Pró-Cardíaco, Rio de Janeiro, RJ (Brazil); Miranda, Sandra Marina; Oliveira, Aline Ribeiro [Universidade Federal Fluminense - UFF, Niterói, RJ (Brazil); Gutterres, Ricardo Fraga [Comissão Nacional de Energia Nuclear - CNEN (Brazil); Mesquita, Evandro Tinoco; Mesquita, Cláudio Tinoco [Universidade Federal Fluminense - UFF, Niterói, RJ (Brazil); Hospital Pró-Cardíaco, Rio de Janeiro, RJ (Brazil)

    2014-11-15

    Appropriateness Criteria for nuclear imaging exams were created by American College of Cardiology (ACC) e American Society of Nuclear Cardiology (ASNC) to allow the rational use of tests. Little is known whether these criteria have been followed in clinical practice. To evaluate whether the medical applications of myocardial perfusion scintigraphy (MPS) in a private nuclear medicine service of a tertiary cardiology hospital were suitable to the criteria of indications proposed by the American medical societies in 2005 and 2009 and compare the level of indication of both. We included records of 383 patients that underwent MPS, November 2008 up to February 2009. Demographic characteristics, patient's origin, coronary risk factors, time of medical graduation and appropriateness criteria of medical applications were studied. The criteria were evaluated by two independent physicians and, in doubtful cases, defined by a medical expert in MPS. Mean age was 65 ± 12 years. Of the 367 records reviewed, 236 (64.3%) studies were performed in men and 75 (20.4%) were internee. To ACC 2005, 255 (69.5%) were considered appropriate indication and 13 (3.5%) inappropriate. With ACC 2009, 249 (67.8%) were considered appropriate indications and 13 (5.2%) inappropriate. We observed a high rate of adequacy of medical indications for MPS. Compared to the 2005 version, 2009 did not change the results.

  20. Assessment of transient dilation of the left ventricular cavity in patients with hypertrophic cardiomyopathy by exercise thallium-201 scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Sugihara, Hiroki; Shiga, Kouji; Umamoto, Ikuo (Kyoto Prefectural Univ. of Medicine (Japan)) (and others)

    1990-11-01

    Exercise Tl scintigraphy (EX-Tl) provides a noninvasive means of identifying myocardial perfusion abnormalities in patients (pts) with hypertrophic cardiomyopathy (HCM). We have noted that some pts with HCM have a pattern of transient dilation of the left ventricle (LV) on the immediate post exercise images as compared with 3 hour redistribution images. We presumed that left ventricular dilation was caused by subendocardial hypoperfusion. So we studied transient dilation of the LV in 50 pts with HCM and 20 controls (C). Initial and delayed conventional short tomographic images were obtained after reconstruction of 30 projections acquired over 180 degrees. Thirty six radii every 10 degrees were generated from the center of the middle myocardial images of the short axis. An area surrounded by the thirty six points of maximal count on each radius was calculated in initial and delayed images. Transient dilation index (TDI) as an index of dilation was determined by dividing an area in initial image by an area in delayed image. TDI in pts with HCM was larger than that in C. Pts with HCM were classified into the two groups, Group A: TDI>1.11 (mean+2 SD in C), 24 pts, Group B: TDI>1.11, 26 pts. Frequency of pts with history of chest pain in Group A was higher than that in Group B, and frequency of pts with positive exercise ECG in Group A was higher than that in Group B. End diastolic volume in Group B did not change 10 minutes after exercise by radionuclide ventriculography. In conclusion, transient dilation of the LV in pts with HCM by Ex-Tl is in appearance, and may reflect subendocardial ischemia. (author).

  1. The perfusion pattern in coronary artery occlusion: comparison of exercise and adenosine.p6.

    Science.gov (United States)

    Iskandrian, A S; Kegel, J; Heo, J; Ogilby, J D; Untereker, W J; Cave, V

    1992-12-01

    This study compared exercise to adenosine thallium-201 single photon emission computed tomography in detecting occlusion of left anterior descending or right coronary arteries in patients with no previous myocardial infarction. There were 41 patients who underwent adenosine thallium imaging (adenosine infusion at a rate of 140 micrograms/kg/min for 6 min), and 143 patients who underwent exercise thallium imaging. There were more patients with right coronary than left anterior descending coronary artery occlusion. Thus, in the adenosine group, there were 15 patients with left anterior descending artery occlusion, and 26 with right coronary artery occlusion, and in the exercise group, there were 46 patients with left anterior descending artery occlusion, and 97 patients with right coronary artery occlusion. In the adenosine group, the thallium images were abnormal in 41 patients (100%), while in the exercise group, the thallium images were abnormal in 125 patients (87%, P exercise group (P:NS). In patients with isolated single vessel occlusion, the size of the perfusion abnormality was 28 +/- 9% with adenosine, and 21 +/- 12% with exercise (P:NS). Thus, most patients with occlusion of the left anterior descending or right coronary artery have regional perfusion abnormality during stress; the different role of collaterals with each type of stress may explain the higher percentage of abnormal results with adenosine than exercise.

  2. Temporal Trends in the Prevalence, Severity, and Localization of Myocardial Ischemia and Necrosis at Myocardial Perfusion Imaging After Myocardial Infarction.

    Science.gov (United States)

    Nudi, Francesco; Schillaci, Orazio; Di Belardino, Natale; Versaci, Francesco; Tomai, Fabrizio; Pinto, Annamaria; Neri, Giandomenico; Procaccini, Enrica; Nudi, Alessandro; Frati, Giacomo; Biondi-Zoccai, Giuseppe

    2017-10-15

    The definition, presentation, and management of myocardial infarction (MI) have changed substantially in the last decade. Whether these changes have impacted on the presence, severity, and localization of necrosis at myocardial perfusion imaging (MPI) has not been appraised to date. Subjects undergoing MPI and reporting a history of clinical MI were shortlisted. We focused on the presence, severity, and localization of necrosis at MPI with a retrospective single-center analysis. A total of 10,476 patients were included, distinguishing 5 groups according to the period in which myocardial perfusion scintigraphy had been performed (2004 to 2005, 2006 to 2007, 2008 to 2009, 2010 to 2011, 2012 to 2013). Trend analysis showed over time a significant worsening in baseline features (e.g., age, diabetes mellitus, and Q waves at electrocardiogram), whereas medical therapy and revascularization were offered with increasing frequency. Over the years, there was also a lower prevalence of normal MPI (from 16.8% to 13.6%) and ischemic MPI (from 35.6% to 32.8%), and a higher prevalence of ischemic and necrotic MPI (from 12.0% to 12.7%) or solely necrotic MPI (from 35.7% to 40.9%, p necrosis (from 19.8% to 8.2%) and moderate necrosis (from 8.5% to 7.8%, p = 0.028). These trends were largely confirmed at regional level and after propensity score matching. In conclusion, the outlook of stable patients with previous MI has substantially improved in the last decade, with a decrease in the severity of residual myocardial ischemia and necrosis, despite an apparent worsening in baseline features. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Measurement of myocardial perfusion and infarction size using computer-aided diagnosis system for myocardial contrast echocardiography.

    Science.gov (United States)

    Du, Guo-Qing; Xue, Jing-Yi; Guo, Yanhui; Chen, Shuang; Du, Pei; Wu, Yan; Wang, Yu-Hang; Zong, Li-Qiu; Tian, Jia-Wei

    2015-09-01

    Proper evaluation of myocardial microvascular perfusion and assessment of infarct size is critical for clinicians. We have developed a novel computer-aided diagnosis (CAD) approach for myocardial contrast echocardiography (MCE) to measure myocardial perfusion and infarct size. Rabbits underwent 15 min of coronary occlusion followed by reperfusion (group I, n = 15) or 60 min of coronary occlusion followed by reperfusion (group II, n = 15). Myocardial contrast echocardiography was performed before and 7 d after ischemia/reperfusion, and images were analyzed with the CAD system on the basis of eliminating particle swarm optimization clustering analysis. The myocardium was quickly and accurately detected using contrast-enhanced images, myocardial perfusion was quantitatively calibrated and a color-coded map calibrated by contrast intensity and automatically produced by the CAD system was used to outline the infarction region. Calibrated contrast intensity was significantly lower in infarct regions than in non-infarct regions, allowing differentiation of abnormal and normal myocardial perfusion. Receiver operating characteristic curve analysis documented that -54-pixel contrast intensity was an optimal cutoff point for the identification of infarcted myocardium with a sensitivity of 95.45% and specificity of 87.50%. Infarct sizes obtained using myocardial perfusion defect analysis of original contrast images and the contrast intensity-based color-coded map in computerized images were compared with infarct sizes measured using triphenyltetrazolium chloride staining. Use of the proposed CAD approach provided observers with more information. The infarct sizes obtained with myocardial perfusion defect analysis, the contrast intensity-based color-coded map and triphenyltetrazolium chloride staining were 23.72 ± 8.41%, 21.77 ± 7.8% and 18.21 ± 4.40% (% left ventricle) respectively (p > 0.05), indicating that computerized myocardial contrast echocardiography can

  4. Selective cerebro-myocardial perfusion in complex congenital aortic arch pathology: a novel technique.

    Science.gov (United States)

    De Rita, Fabrizio; Lucchese, Gianluca; Barozzi, Luca; Menon, Tiziano; Faggian, Giuseppe; Mazzucco, Alessandro; Luciani, Giovanni Battista

    2011-11-01

    Simultaneous cerebro-myocardial perfusion has been described in neonatal and infant arch surgery, suggesting a reduction in cardiac morbidity. Here reported is a novel technique for selective cerebral perfusion combined with controlled and independent myocardial perfusion during surgery for complex or recurrent aortic arch lesions. From April 2008 to April 2011, 10 patients with arch pathology underwent surgery (two hypoplastic left heart syndrome [HLHS], four recurrent arch obstruction, two aortic arch hypoplasia + ventricular septal defect [VSD], one single ventricle + transposition of the great arteries + arch hypoplasia, one interrupted aortic arch type B + VSD). Median age was 63 days (6 days-36 years) and median weight 4.0 kg (1.6-52). Via midline sternotomy, an arterial cannula (6 or 8 Fr for infants) was directly inserted into the innominate artery or through a polytetrafluoroethylene (PTFE) graft (for neonates cerebro-myocardial perfusion was 39 ± 18 min (17-69). Weaning from cardiopulmonary bypass was achieved without inotropic support in three and with low dose in seven patients. One patient required veno-arterial extracorporeal membrane oxygenation. Four patients, body weight cerebro-myocardial perfusion is feasible in patients with complex or recurrent aortic arch disease, starting from premature newborn less than 2.0 kg of body weight to adults. The technique is as safe as previously reported methods of cerebro-myocardial perfusion and possibly more versatile. © 2011, Copyright the Authors. Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  5. The influence of clopidogrel on ischemia diagnosed by myocardial perfusion stress testing.

    Science.gov (United States)

    Jovin, Ion S; Ebisu, Keita A; Oprea, Adriana D; Brandt, Cynthia A; Natale, Donna; Finta, Laurie A; Dziura, James; Wackers, Frans J

    2016-08-01

    Clopidogrel is a platelet adenosine receptor antagonist which can influence coronary vascular tone and thus can potentially interfere with myocardial perfusion imaging. We investigated whether clopidogrel can hamper the diagnosis of ischemia in patients undergoing myocardial perfusion testing. Data from a database of 6349 myocardial perfusion stress tests were analyzed. Using a propensity analysis, patients who were taking clopidogrel were compared with patients not taking clopidogrel for the presence of reversible perfusion defects on myocardial single-photon emission computed tomography scans. Of the 6349 tests, the stress technique was adenosine in 2713 patients and exercise in 3636. At the time of the stress test, 277 (4.3%) of the patients were taking clopidogrel. The odds ratio (OR) for patients taking clopidogrel to have a reversible perfusion defect was 2.75 (95% confidence interval [CI] 2.09-3.62; P clopidogrel, the OR was 1.06 (CI 0.76-1.49; P = .73) for patients undergoing adenosine stress tests and 1.60 (CI 0.85-3.00; P = .14) for patients undergoing exercise stress tests. We found no evidence that the use of clopidogrel decreases the likelihood of ischemia on adenosine or exercise stress myocardial perfusion scans.

  6. Assessment of myocardial perfusion and function in victims of scorpion envenomation using gated-SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Figueiredo, Alexandre Baldini de; Cupo, Palmira; Pintya, Antonio O.; Caligaris, Fabio; Marin-Neto, Jose A; Hering, Sylvia E.; Simoes, Marcus Vinicius, E-mail: simoesmv@yahoo.co [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Hospital das Clinicas

    2010-04-15

    Background: cardiogenic shock and acute pulmonary edema are the major causes of death of patients with scorpion envenomation, whose pathophysiological mechanism remains controversial. Objective: to investigate the correlation between myocardial perfusion abnormalities and left ventricular contractile function in victims of scorpion envenomation. Methods: fifteen patients underwent ECG-gated myocardial perfusion scintigraphy (gated SPECT) within 72 hours of, and 15 days after scorpion envenomation. Images were analyzed by means of a semi-quantitative visual perfusion score (0 = normal, 4 = absent) and motion score (0 = normal, 4 akinesia), using the 17-segment model. Summed perfusion (SPS) and summed motion (SMS) scores were calculated for each patient. Ejection fraction (LVEF) was calculated by a commercially available software. Results: at baseline, 12 out of the 15 patients presented abnormal myocardial perfusion and contractility. Mean values of SPS, SMS and LVEF were 12.5 +- 7.3, 17.0 +- 12.8, and 44.6 +- 16.0%, respectively. A positive correlation between SPS and SMS (r = 0.68; p = 0.005) and negative correlation between SPS and LVEF (r -0.75; p = 0.0021) were found. The follow-up studies showed recovery of global contractility (LVEF of 68.9 +- 9.5, p = 0.0002), segmental contractility (SMS of 2.6 +- 3.1, p = 0.0009) and perfusion (SPS of 3.7 +- 3.3, p = 0.0003). Improvement of LVEF correlated positively with improvement of SPS (r = 0.72; p = 0.0035). Conclusions: myocardial perfusion abnormalities are common in scorpion envenomation and correlate topographically with the contractile dysfunction. Recovery of contractility correlates with reversibility of perfusion defects. These findings suggest the participation of myocardial perfusion abnormalities in the pathophysiology of this form of acute ventricular failure. (author)

  7. Detection of myocardial ischemia with myocardial perfusion SPECT in patients with diabetes mellitus

    Energy Technology Data Exchange (ETDEWEB)

    Seo, J. H.; Jeong, S. Y.; Bae, J. H.; Anh, B. C.; Lee, J.; Lee, K. B [Kyungpook National University Hospital, Daegu (Korea, Republic of)

    2004-07-01

    Diabetes mellitus(DM) is a critical disease associated with higher rates of cardiovascular morbidity and mortality. Atherosclerosis accounts for 65-80% of all deaths in diabetic patients and patients with DM are known to show high prevalence of coronary artery diseases(CAD). We evaluated the incidence of scintigraphic evidence of CAD in diabetic patients and results were compared with cardiovascular symptoms and clinical factors. 169 patients with DM(mean age 629years, 68 males) were referred for evaluation of CAD between Jan 2002 and Dec 2003. 101(60%) patients were with chest pain and 68(40%) were asymptomatic. Patients underwent exercise(n=6) or adenosine stress(n=163) SPECT myocardial perfusion imaging(MPI). Exclusion criteria included history of documented myocardial infarction, prior revascularization, clinically significant valvular heart disease, left-bundle branch block on rest ECG. We evaluated symptoms associated with cardiac problem and other clinical and laboratory data to reveal correlation with presence of CAD. MPI were assessed visually and semi-quantitatively with C-Equal program. Myocardial ischemia was detected in 52(31%) patients. Among them, 41 had 1-vessel and 9 had 2-vessel disease. In 52 patients with ischemia, 28(54%) were male and 24(46%) were female. 20/68(29%) asymptomatic and 32/101(32%) symptomatic patients had ischemia. Higher prevalence of neuropathy, hypertension, higher blood glucose level, HbA1c and CRP was noted in patients with myocardial ischemia. Serum levels of cholesterol and LDL was not significantly different between patients with ischemia and with normal MPI findings. Abnormal MPI findings were not related with gender and age. These results show a high prevalence of abnormal MPI results in diabetic patients regardless of symptoms. Screening stress MPI in diabetic patients should be indicated irrespective of symptoms, especially in patients with neuropathy, hypertension, higher level of blood glucose, or increased CRP.

  8. Multidetector-row computed tomographic evaluation of myocardial perfusion in reperfused chronic myocardial infarction: value of color-coded perfusion map in a porcine model.

    Science.gov (United States)

    Yim, Nam Yeol; Kim, Yun-Hyeon; Choi, Song; Seon, Hyun Ju; Kim, Yeong Cheol; Jeong, Gwang Woo; Min, Byeong In; Lee, Sang Rok; Jeong, Myeong Ho; Kim, Jae Kyu; Park, Jin Gyoon; Kang, Heoung Keun

    2009-04-01

    We aimed to develop color-coded CT perfusion maps (CPM) of infarcted myocardium and assess the utility of CPM in evaluating ischemic heart disease on a cardiac multi-detector CT (MDCT) in a porcine reperfused-myocardial-infarction model. Myocardial infarctions were induced by 30 min occlusions of the proximal left anterior descending coronary artery (LAD) in 17 healthy adult female pigs. First-pass and 5 min-delayed cardiac MDCTs were performed after 4 weeks of LAD occlusion. Myocardial CPMs were obtained by using the CPM program. Triphenyltetrazolium chloride (TTC)-staining was performed on the cardiac specimens. We analyzed the intermodality agreement on the size and location of the myocardial infarctions. TTC staining revealed myocardial infarction in 16 of 17 pigs, and 15 of these (94%) showed matched infarcts on the CPM and first-pass images. The areas of perfusion deficit noted in early arterial phase images and CPM coincided exactly with the areas of poor TTC staining in 12 of 15 pigs (80%). In the three remaining pigs, the areas of poor TTC staining were larger than those of a perfusion deficit demonstrated by either early arterial phase images or CPM. The agreement between these tests is calculated to be moderate to good (k = 0.736, P infarction; CPM was helpful in visualizing the infarcted myocardium.

  9. Perfusion Computed Tomography for the Assessment of Myocardial Viability — a Case Series

    Directory of Open Access Journals (Sweden)

    Morariu Mirabela

    2016-06-01

    Full Text Available Myocardial viability plays an important role in preventing the development of left ventricular remodeling following an acute myocardial infarction. A preserved viability in the infarcted area has been demonstrated to be associated with a lower amplitude of the remodeling process, while the extent of the non-viable myocardium is directly correlated with the amplitude of the remodeling process. A number of methods are currently in use for the quantification of the viable myocardium, and some of them are based on the estimation of myocardial perfusion during pharmacologic stress. 64-slice Multi-detector Computed Tomography (MDCT during vasodilator stress test, associated with CT Coronary Angiography (CCTA has a high diagnostic accuracy in evaluating myocardial perfusion. In this article, we present a sequence of 3 clinical cases that presented with symptoms of myocardial ischemia, who underwent 64-slice MDCT imaging at rest and during adenosine stress test, in order to assess the extent of the hypoperfused myocardial areas. Coronary artery anatomy and the Coronary Calcium Score was assessed for all 3 patients by performing CT Coronary Angiography. The combination of CT Angiography and adenosine stress CT myocardial perfusion imaging can accurately detect atherosclerosic lesions that cause perfusion abnormalities, compared with the combination of invasive angiography and single-photon emission computed tomography (SPECT.

  10. Slaughterhouse blood as a perfusate for studying myocardial function under ischemic conditions

    Directory of Open Access Journals (Sweden)

    Bendjelid K.

    2003-01-01

    Full Text Available Metabolic studies using the in vitro non-recirculating blood-perfused isolated heart model require large volumes of blood. The present study was designed to determine whether heterologous pig blood collected from a slaughterhouse can be used as perfusate for isolated pig hearts perfused under aerobic and constant reduced flow conditions. Eight isolated working pig hearts perfused for 90 min at a constant flow of 1.5 ml g-1 min-1 with non-recirculated blood diluted with Krebs-Henseleit bicarbonate buffer at a hematocrit of 23% were compared to eight hearts subjected to the same protocol but perfused only with Krebs-Henseleit bicarbonate buffer solution. Hearts were paced at 100 bpm and subjected to aerobic perfusion at 38ºC. Hearts were weighed before perfusion and at the end of the experiment and the results are reported as percent weight gain (mean ± SD. Comparisons between groups were performed by the Student t-test (P<0.05. After 90 min of perfusion with modified Krebs-Henseleit, perfused hearts presented a larger weight gain than blood-perfused hearts (39.34 ± 9.27 vs 23.13 ± 5.42%, P = 0.003. Left ventricular end-diastolic pressure was higher in the modified Krebs-Henseleit-perfused group than in the blood group (2.8 ± 0.4 vs 2.3 ± 0.3 mmHg, respectively, P = 0.01. We conclude that heterologous blood perfusion, by preserving a more physiological myocardial water content, is a better perfusion fluid than modified Krebs-Henseleit solution for quantitative studies of myocardial metabolism and heart function under ischemic conditions.

  11. Myocardial perfusion imaging determination using an appropriate use smartphone application.

    Science.gov (United States)

    Mahajan, Ashish; Bal, Susan; Hahn, Harvey

    2015-02-01

    Inappropriate cardiac imaging has been a significant cost concern and cause of radiation burden to patients. To assess if a smartphone application (app) based on 2009 Appropriate Use Criteria (AUC) for Cardiac Radionuclide Imaging published by American College of Cardiology would be feasible at the point of order. We evaluated stress myocardial perfusion imaging (MPI) (N = 403) (mean age = 62.23 years; 47.89% males) over a 4 month period using a smartphone app to determine whether the study ordered was Appropriate, Inappropriate, or Uncertain per 2009 AUC. We also monitored the time needed to use the app to determine the level of appropriateness of each stress MPI. The results of the stress MPI were noted. Of the 403 stress MPIs evaluated, 267 (66.25%) were noted to be Appropriate, 118 (29.28%) were Inappropriate, and 13 (3.23%) were Uncertain, per AUC; 5 (1.25%) remained unclassified. Average time needed to use the app to assess each stress MPI for appropriateness was noted to be 44 (±9) seconds. Non-teaching physicians ordered 70 (38.89%) inappropriate stress MPIs as compared to 20 (23.53%) ordered by physicians on resident teaching service, and 28 (23.33%) by cardiologists (P = .0045). Among inappropriately ordered stress MPIs, 87 (42.65%) were ordered in females as compared to 31 (17.13%) in males (P smartphone app provides an easy-to-use tool to assist physicians in determining the level of appropriateness of stress MPI in a time- and cost-effective manner at the point of order. The smartphone app may have potential to promote the usage of the AUC and possibly aid reduction of healthcare cost and ionizing radiation burden.

  12. Electrocardiographic left ventricular hypertrophy without echocardiographic abnormalities evaluated by myocardial perfusion and fatty acid metabolic imaging

    Energy Technology Data Exchange (ETDEWEB)

    Narita, Michihiro; Kurihara, Tadashi [Sumitomo Hospital, Osaka (Japan)

    2000-01-01

    The pathophysiologic process in patients with electrocardiographic left ventricular hypertrophy with ST, T changes but without echocardiographic abnormalities was investigated by myocardial perfusion imaging and fatty acid metabolic imaging. Exercise stress {sup 99m}Tc-methoxy-isobutyl isonitrile (MIBI) imaging and rest {sup 123}I-beta-methyl-p-iodophenyl pentadecanoic acid (BMIPP) imaging were performed in 59 patients with electrocardiographic hypertrophy including 29 without apparent cause including hypertension and echocardiographic hypertrophy, and 30 with essential hypertension. Coronary angiography was performed in 6 patients without hypertension and 4 with hypertension and biopsy specimens were obtained from the left ventricular apex from 6 patients without hypertension. Myocardial perfusion and {sup 123}I-BMIPP images were classified into 3 types: normal, increased accumulation of the isotope at the left ventricular apex (high uptake) and defect. Transient perfusion abnormality and apical defect observed by {sup 123}I-BMIPP imaging were more frequent in patients without hypertension than in patients with hypertension (32% vs. 17%, p=0.04671 in perfusion; 62% vs. 30%, p=0.0236 in {sup 123}I-BMIPP). Eighteen normotensive patients with apical defect by {sup 123}I-BMIPP imaging included 3 of 10 patients with normal perfusion at exercise, 6 of 10 patients with high uptake and 9 of 9 patients with perfusion defect. The defect size revealed by {sup 123}I-BMIPP imaging was greater than that of the perfusion abnormality. Coronary stenoses were not observed and myocardial specimens showed myocardial disarray with hypertrophy. Moreover, 9 patients with hypertension and apical defects by {sup 123}I-BMIPP showed 3 different types of perfusion. Many patients without hypertension show a pathologic process similar to hypertrophic cardiomyopathy. Perfusion and {sup 123}I-BMIPP imaging are useful for the identification of these patients. (author)

  13. Acute myocardial infarction: estimation of at-risk and salvaged myocardium at myocardial perfusion SPECT 1 month after infarction.

    Science.gov (United States)

    Romero-Farina, Guillermo; Aguadé-Bruix, Santiago; Candell-Riera, Jaume; Pizzi, M Nazarena; Pineda, Victor; Figueras, Jaume; Cuberas, Gemma; de León, Gustavo; Castell-Conesa, Joan; García-Dorado, David

    2013-11-01

    To estimate at-risk and salvaged myocardium by using gated single photon emission computed tomography (SPECT) myocardial perfusion imaging after acute myocardial infarction (AMI). The study was approved by the hospital's Ethical Committee on Clinical Trials (trial register number, PR(HG)36/2000), and all patients gave informed consent. Forty patients (mean age, 61.78 years; eight women) with a first AMI underwent two gated SPECT examinations--one before percutaneous coronary intervention (PCI) and one 4-5 weeks after PCI. Myocardium at risk was estimated by assessing the perfusion defect at the first gated SPECT examination, and salvaged myocardium was estimated by assessing the risk area minus necrosis at the second examination. Myocardium at risk was estimated by determining the discordance between the areas of left ventricular (LV) wall motion and perfusion at the second examination. Concordance between tests was analyzed by means of linear regression analysis, the Pearson correlation, the intraclass correlation coefficient, and Bland-Altman analysis. An improvement in perfusion, wall motion, wall thickening, and LV ejection fraction (P Myocardial perfusion gated SPECT performed 1 month after early PCI in a first AMI provides potentially useful information on at-risk and salvaged myocardium. http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.13122324/-/DC1. RSNA, 2013

  14. Effect of beam hardening on transmural myocardial perfusion quantification in myocardial CT imaging

    Science.gov (United States)

    Fahmi, Rachid; Eck, Brendan L.; Levi, Jacob; Fares, Anas; Wu, Hao; Vembar, Mani; Dhanantwari, Amar; Bezerra, Hiram G.; Wilson, David L.

    2016-03-01

    The detection of subendocardial ischemia exhibiting an abnormal transmural perfusion gradient (TPG) may help identify ischemic conditions due to micro-vascular dysfunction. We evaluated the effect of beam hardening (BH) artifacts on TPG quantification using myocardial CT perfusion (CTP). We used a prototype spectral detector CT scanner (Philips Healthcare) to acquire dynamic myocardial CTP scans in a porcine ischemia model with partial occlusion of the left anterior descending (LAD) coronary artery guided by pressure wire-derived fractional flow reserve (FFR) measurements. Conventional 120 kVp and 70 keV projection-based mono-energetic images were reconstructed from the same projection data and used to compute myocardial blood flow (MBF) using the Johnson-Wilson model. Under moderate LAD occlusion (FFR~0.7), we used three 5 mm short axis slices and divided the myocardium into three LAD segments and three remote segments. For each slice and each segment, we characterized TPG as the mean "endo-to-epi" transmural flow ratio (TFR). BH-induced hypoenhancement on the ischemic anterior wall at 120 kVp resulted in significantly lower mean TFR value as compared to the 70 keV TFR value (0.29+/-0.01 vs. 0.55+/-0.01 p<1e-05). No significant difference was measured between 120 kVp and 70 keV mean TFR values on segments moderately affected or unaffected by BH. In the entire ischemic LAD territory, 120 kVp mean endocardial flow was significantly reduced as compared to mean epicardial flow (15.80+/-10.98 vs. 40.85+/-23.44 ml/min/100g; p<1e-04). At 70 keV, BH was effectively minimized resulting in mean endocardial MBF of 40.85+/-15.3407 ml/min/100g vs. 74.09+/-5.07 ml/min/100g (p=0.0054) in the epicardium. We also found that BH artifact in the conventional 120 kVp images resulted in falsely reduced MBF measurements even under non-ischemic conditions.

  15. Evaluation of myocardial CT perfusion in patients presenting with acute chest pain to the emergency department: comparison with SPECT-myocardial perfusion imaging.

    Science.gov (United States)

    Feuchtner, Gudrun Maria; Plank, Fabian; Pena, Constantino; Battle, Juan; Min, James; Leipsic, Jonathon; Labounty, Troy; Janowitz, Warren; Katzen, Barry; Ziffer, Jack; Cury, Ricardo C

    2012-10-01

    To determine whether evaluation of resting myocardial CT perfusion (CTP) from coronary CT angiography (CTA) datasets in patients presenting with chest pain (CP) to the emergency department (ED), might have added value to coronary CTA. 76 Patients (age 54.9 y±13; 32 (42%) women) presenting with CP to the ED underwent coronary 64-slice CTA. Myocardial perfusion defects were evaluated for CTP (American Heart Association 17-segment model) and compared with rest sestamibi single-photon emission CT myocardial perfusion imaging (SPECT-MPI). CTA was assessed for >50% stenosis per vessel. CTP demonstrated a sensitivity of 92% and 89%, specificity of 95% and 99%, positive predictive value (PPV) of 80% and 82% and negative predictive value (NPV) of 98% and 99% for each patient and for each segment, respectively. CTA showed an accuracy of 92%, sensitivity of 70.4%, specificity of 95.5%, PPV 67.8%, and NPV of 95% compared with SPECT-MPI. When CTP findings were added to CTA the PPV improved from 67% to 90.1%. In patients presenting to the ED with CP, the evaluation of rest myocardial CTP demonstrates high diagnostic performance as compared with SPECT-MPI. Addition of CTP to CTA improves the accuracy of CTA, primarily by reducing rates of false-positive CTA.

  16. Nuclear myocardial perfusion imaging with a cadmium-telluride semiconductor detector gamma camera in patients with acute myocardial infarction.

    Science.gov (United States)

    Fukushima, Yoshimitsu; Kumita, Shin-ichiro; Kawaguchi, Tsuneaki; Maruyama, Takatoshi; Kawasaki, Yoshiyuki; Shinkai, Yasuhiro

    2014-08-01

    Since myocardial perfusion imaging (MPI) with conventional sodium iodine (NaI) device has low spatial resolution, there have been some cases in which small structures such as non-transmural myocardial infarction could not be properly detected. The purpose of this study was to evaluate potential usefulness of cadmium-telluride (CdTe) semiconductor detector-based high spatial resolution gamma cameras in detecting myocardial infarction sites, especially non-transmural infarction. A total of 38 patients (mean age ± SD: 64 ± 21 year) who were clinically diagnosed with acute myocardial infarction were included. Twenty-eight cases of them were with ST segment elevation myocardial infarction (STEMI) and 10 cases with non-ST segment elevation myocardial infarction (NSTEMI). In all patients, myocardial perfusion single photon emission computed tomography images were acquired with Infinia (NaI device) and R1-M (CdTe device), and the images were compared concerning the detectability of acute myocardial infarction sites. The detection rates of the myocardial infarction site in cases with STEMI were 100% both by NaI and CdTe images. In cases with NSTEMI, detection rate by NaI images was 50%, while that of CdTe images was 100% (p = 0.033). The summed rest score (SRS) value derived from CdTe images was significantly higher than that from NaI images in cases with STEMI [NaI images: 12 (7-18) versus CdTe images: 14 (9-20)] (p cases with NSTEMI [NaI images: 2 (0-5) versus CdTe images: 6 (6-8)] (p = 0.006). These results indicate that MPI using CdTe-semiconductor device will provide a much more accurate assessment of acute myocardial infarction in comparison to current methods.

  17. Discrepancy between myocardial perfusion and fatty acid metabolism following acute myocardial infarction for evaluating the dysfunctional viable myocardium.

    Science.gov (United States)

    Biswas, Shankar K; Sarai, Masayoshi; Toyama, Hiroshi; Hishida, Hitoshi; Ozaki, Yukio

    2012-01-01

    Following acute myocardial infarction (AMI) the area of myocardial perfusion and metabolism mismatch is designated as dysfunctional viable myocardium. (123)I-beta-methyl iodophenyl pentadecanoic acid (BMIPP) is clinically very useful for evaluating myocardial fatty acid metabolism, and (99)mTc-Tetrofosmin (TF) is a widely used tracer for myocardial perfusion. This study was designed to evaluate the degree of discrepancy between BMIPP and TF at the subacute state of AMI. Fifty-two patients (aged 59 ± 10 years; mean 46 years) with AMI were enrolled, and all of them underwent percutaneous coronary intervention (PCI). Patients were classified according to ST-T change and PCI timing. (123)I-beta-methyl iodophenyl pentadecanoic acid and TF cardiac scintigraphy were performed on 7 ± 3.5 days of admission using a dual headed gamma camera. Perfusion and fatty acid metabolism defect were scored on a 17 segments model. The mean BMIPP defect score on early and delayed images were 16.67 ± 10.19 and 16.25 ± 10.40, respectively. The mean TF defect score was 10 ± 7.69. Defect score of BMIPP was significantly higher than that of the TF (P TF), and 5 (10%) patients showed matched defect (BMIPP = TF). Mismatched defect score (MMDS) was significantly higher in patients with ST-segment elevation myocardial infarction (STEMI) than that of non-ST-segment elevation myocardial infarction (NSTEMI) (P < 0.041; 95% CI 0.11-5.19). At the subacute state of AMI, most of the patients showed perfusion-metabolism mismatch, which represents the dysfunctional viable myocardium, and patients with STEMI showed higher mismatch. Copyright © 2012 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  18. Myocardial fatty acid imaging using iodine-123-BMIPP in patients with hypertensive intracranial hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Hashizume, Toshikazu; Sakai, Yasuhito; Hayashi, Yasushi [National Minamiwakayama Hospital, Tanabe (Japan)

    2000-07-01

    An evaluation of myocardial fatty acid metabolism in hypertensive patients with major complication has not been previously established. To assess the myocardial fatty acid metabolism in hypertensive patients with intracranial hemorrhage (IH), we performed myocardial image using {sup 123}I-15-p-iodophenyl-3-methyl pentadecanoic acid (BMIPP). Seventeen hypertensive patients with IH (HIH) and 27 hypertensive patients without IH (HT) were studied. A dose of 111 MBq of BMIPP was injected intravenously at rest, and a myocardial image was recorded 30 minutes after the injection. Myocardial perfusion image using Thallium-201 (Tl) was also performed within 2 weeks after BMIPP study. The regional myocardial uptakes of BMIPP and Tl were visually assessed in 17 segments with a four-point scoring system (0=absent to 3=normal uptake). Cardiac hypertrophy was evaluated by electrocardiogrpahy (ECG) and two-dimensional ultrasonic cardiography (UCG). Sum of uptake scores of Tl was similar in both groups (45.1{+-}5.4 vs. 47.9{+-}4.2), but that of BMIPP in HIH was lower than HT (35.9{+-}7.9 vs 45.6{+-}4.8, p<0.001). Evaluation of cardiac hypertrophy using ECG and UCG revealed no significant difference between two groups. HIH have much more eccentric hypertrophy in UCG study than HT (53% vs. 37%). These data suggest that hypertensive patients with intracranial hemorrhage have a more impaired myocardial fatty acid metabolism compared to the hypertensive patients with similar cardiac hypertrophy. BMIPP imaging might be useful to evaluate the severity of myocardial fatty acid metabolism in hypertensive patients. (author)

  19. Study of myocardial regional wall motion parameter's accuracy by software perfusion phantom.

    Science.gov (United States)

    Fidler, V; Fettich, J; Prepadnik, M

    1992-06-01

    Gated perfusion myocardial scintigraphy permits simultaneous evaluation of perfusion as well as regional contractile function of the left ventricle. Fourier analysis of regional myocardial spatial movement with respect to the myocardial geometric centre gives circular amplitude and phase profiles of ventricular contraction, in addition to regional maximum activity that represents an index of perfusion. To introduce such combined perfusion-contraction analysis the accuracy of the indices mentioned above should be evaluated for different doses of radioactivity typically administered to a patient. A mathematical software phantom, consisting of a half circularly profiled ring activity embedded in uniform background activity and noise generated by a Poisson-shaped random number generator, was constructed and used for this purpose. A 64 x 64 matrix and sequence of 16 frames per study was used. The maximum number of counts per pixel ranged from 10 to 100, simulating low count thallium and high count rate Tc-MIBI-gated studies. The relative standard error analysis (R.S.E.) with a 95.5% confidence level for a thallium type of 10 counts per pixel study exceeded 11%, while it reached acceptable values below 3% for studies with 60 and more counts per pixel. These results indicate that high count rate gated technetium-MIBI myocardial perfusion studies could also be used for reliable left ventricular regional wall motion evaluation.

  20. When is reacquisition necessary due to high extra-cardiac uptake in myocardial perfusion scintigraphy?

    DEFF Research Database (Denmark)

    Johansen, Allan; Lomsky, Milan; Gerke, Oke

    2013-01-01

    Technetium-labeled agents, which are most often used for assessing myocardial perfusion in myocardial perfusion scintigraphy (MPS), are cleared by the liver and excreted by the biliary system. Spillover from extra-cardiac activity into the myocardium, especially the inferior wall, might conceal d...... defects and lower the diagnostic accuracy of the study. The objective was to determine rules of thumb for when reacquisition is useful due to high extra-cardiac uptake, i.e., when interpretation of the studies was affected by poor image quality....

  1. Interarterial course of the right coronary artery: assessment with cardiac computed tomography and myocardial perfusion imaging.

    Science.gov (United States)

    Husmann, Lars; Valenta, Ines; Veit-Haibach, Patrick; Alkadhi, Hatem; Largiader, Thomas; Kaufmann, Philipp A

    2008-05-01

    A 50-year-old well-trained cyclist reported increasing brief episodes of chest pain over the last 8 years at maximum exercise during alpine bicycle training. Previous cardiac stress testing on a supine bicycle ergometer revealed nonspecific ST-T abnormalities. In June 2007, the patient was referred for computed tomography coronary angiography, which revealed a coronary anomaly, with the right coronary artery originating from the left coronary sinus and taking an interarterial course between the ascending aorta and the pulmonary trunk. There were no atherosclerotic alterations in the coronary arteries. Subsequent bicycle exercise stress and myocardial perfusion imaging revealed no myocardial perfusion defect.

  2. Impairment of myocardial perfusion in children with sickle cell disease; Alteration de la perfusion myocardique chez l'enfant drepanocytaire

    Energy Technology Data Exchange (ETDEWEB)

    Maunoury, C. [Hopital Necker-Enfants-Malades, Service de Medecine Nucleaire, 75 - Paris (France); Acar, P. [Centre Hospitalier Universitaire, Hopital des Enfants, Service de Cardiologie Pediatrique, 31 - Toulouse (France); Montalembert, M. de [Hopital Necker-Enfants-Malades, Service de Pediatrie Generale, 75 - Paris (France)

    2003-10-01

    While brain, bone and spleen strokes are well documented in children with sickle cell disease (SCD), impairment of myocardial perfusion is an unknown complication. Non invasive techniques such as exercise testing and echocardiography have a low sensitivity to detect myocardial ischemia in patients with SCD. We have prospectively assessed myocardial perfusion with Tl-201 SPECT in 23 patients with SCD (10 female, 13 male, mean age 12 {+-} 5 years). Myocardial SPECT was performed after stress and 3 hours later after reinjection on a single head gamma camera equipped with a LEAP collimator (64 x 64 matrix size format, 30 projections over 180 deg C, 30 seconds per step). Left ventricular ejection fraction (LVEF) was assessed by equilibrium radionuclide angiography at rest on the same day. Myocardial perfusion was impaired in 14/23 patients: 9 reversible defects and 5 fixed defects. The left ventricular cavity was dilated in 14/23 patients. The mean LVEF was 63 {+-} 9%. There was no relationship between myocardial perfusion and left ventricular dilation or function. The frequent impairment of myocardial perfusion in children with SCD could lead to suggest a treatment with hydroxyurea, an improvement of perfusion can be noted with hydroxyurea. (author)

  3. Myocardial perfusion alterations observed months after radiotherapy are related to the cellular damage

    Energy Technology Data Exchange (ETDEWEB)

    Dogan, I.; Sonmez, B. [Karadeniz Technical Univ., Trabzon (Turkey). Dept. of Nuclear Medicine; Sezen, O.; Zengin, A.Y.; Bahat, Z. [Karadeniz Technical Univ., Trabzon (Turkey). Dept. of Radiation Oncology; Yenilmez, E.; Yulug, E. [Karadeniz Technical Univ., Trabzon (Turkey). Dept. of Histology and Embryology; Abidin, I. [Karadeniz Technical Univ., Trabzon (Turkey). Dept. of Biophysics

    2010-07-01

    Myocardial perfusion scintigraphy (MPS) is one of the widely used tools to follow developing radiation-induced heart disease (RIHD). But the clinical significance of MPS defects has not been fully understood. We have investigated the biodistribution alterations related to perfusion defects following radiotherapy (RT) and showed coexisting morphological changes. Animals, methods: A total of 18 Wistar rats were divided into three groups (1 control and 2 irradiated groups). A single cardiac 20 Gy radiation dose was used to induce long term cardiac defects. Biodistribution studies with technetium ({sup 99m}Tc) sestamibi and histological evaluations were performed 4 and 6 months after irradiation. The percent radioactivity (%ID/g) was calculated for each heart. For determination of the myocardial damage, positive apoptotic cardiomyocytes, myocardial cell degeneration, myocardial fibrosis, vascular damage and ultrastructural structures were evaluated. Results: Six months after treatment, a significant drop of myocardial uptake was observed (p < 0.05). Irradiation-induced apoptosis rose within the first 4 months after radiation treatment and were stayed elevated until the end of the observation period (p < 0.05). Also, the irradiation has induced myocardial degeneration, perivascular and interstitial fibrosis in the heart at the end of six and four months (p < 0.01). The severity and extent of myocardial injury has became more evident at the end of six month (p < 0.05). At ultrastructural level, prominent changes have been observed in the capillary endothelial and myocardial cells. Conclusion: Our findings suggest that the reduced rest myocardial perfusion, occuring months after the radiation, indicates a serious myocard tissue damage which is characterized by myocardial degeneration and fibrosis. (orig.)

  4. GATED SPECT TO EVALUATE LEFT VENTRICULAR MYOCARDIAL PERFUSION, FUNCTION AND DYSSYNCHRONY FOR RESYNCHRONIZATION THERAPY

    Directory of Open Access Journals (Sweden)

    E.N. Ostroumov

    2009-01-01

    Full Text Available The study included 15 consecutive patients with heart failure and substantial LV dyssynchrony undergoing CRT. Clinical and phase analysis of gated myocardial perfusion SPECT assessed at baseline, after 2–3 days and after 3–4 months of CRT. The results demonstrated inversely relationship between the response to CRT and the nonviable myocardium. Evaluation of myocardial viability is necessary to considered in the selection process for CRT.

  5. Reverse Redistribution in Myocardial Perfusion Imaging: Revisited with 64-slice MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Min Kyung; Kim, Jeong Ho; Hwang, Kyung Hoon; Choi, In Suck; Choi, Soo Jin; Choe, Won Sick [Gachon University Gil Hospital, Incheon (Korea, Republic of); Yoon, Min Ki [Good Samaritan Hospital, Pohang (Korea, Republic of)

    2010-06-15

    The authors report myocardial perfusion imaging of a patient showing reverse redistribution (RR) and a 64-slice multidetector-row computed tomography (MDCT) with corresponding findings. The patient had subendocardial myocardial infarction (MI) with positive electrocardiogram (EMG) findings and elevated levels of cardiac isoenzymes. Experiencing this case emphasizes the importance of complementary correlation of a new diagnostic modality that helps us to understand the nature of RR.

  6. Perfusion imaging using rubidium-82 ((82)Rb) PET in rats with myocardial infarction

    DEFF Research Database (Denmark)

    Clemmensen, Andreas Ettrup; Ghotbi, Adam Ali; Bodholdt, Rasmus Poul

    2017-01-01

    of balanced coronary and small vessel disease is possible. For further evaluation of how 82Rb-PET can be used clinically, pre-clinical application of the method would be valuable. However, so far no data on the use of 82Rb-PET in small animals have been published nor has the use of 82Rb-PET, to the best......Assessing myocardial perfusion using 82Rb-PET is emerging as a valuable clinical tool.1,2 The rapid decay (T½ = 76 s) allows for absolute quantification of both rest and stress perfusion within 30 minutes. In addition to evaluation of epicardial disease with perfusion defects, also evaluation...

  7. Prognostic Value of Normal Perfusion but Impaired Left Ventricular Function in the Diabetic Heart on Quantitative Gated Myocardial Perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Hwanjeong; Choi, Sehun; Han, Yeonhee [Research Institute of Chonbuk National Univ. Medical School and Hospitial, Jeonju (Korea, Republic of); Lee, Dong Soo; Lee, Hoyoung; Chung, Junekey [Seoul National Univ., Seoul (Korea, Republic of)

    2013-09-15

    This study aimed at identifying the predictive parameters on quantitative gated myocardial perfusion single-photon emission computed tomography (QG-SPECT) in diabetic patients with normal perfusion but impaired function. Methods Among the 533 consecutive diabetic patients, 379 patients with normal perfusion on rest Tl-201/dipyridamole-stress Tc-{sup 99m} sestamibi Gated SPECT were enrolled. Patients were grouped into those with normal post-stress left ventricular function (Group I) and those with impaired function (EF <50 or impaired regional wall motion, Group II). We investigated cardiac events and cause of death by chart review and telephone interview. Survival analysis and Cox proportional hazard model analysis were performed. Between the Group I and II, cardiac events as well as chest pain symptoms, smoking, diabetic complications were significantly different (P<0.05). On survival analysis, event free survival rate in Group II was significantly lower than in Group I (P=0.016). In univariate Cox proportional hazard analysis on overall cardiac event, Group (II over I), diabetic nephropathy, summed motion score (SMS), summed systolic thickening score (STS), numbers of abnormal segmental wall motion and systolic thickening predicted more cardiac events (P<0.05). Multivariate analysis showed that STS was the only independent predictor cardiac event. The functional parameter, especially summed systolic thickening score on QG-SPECT had prognostic values, despite normal perfusion, in predicting cardiac events in diabetic patients, and QG-SPECT provides clinically useful risk stratification in diabetic patients with normal perfusion.

  8. Correlation of the myocardial perfusion corrected by attenuation with the coronariography. Preliminary results; Correlacion de la perfusion miocardica corregida por atenuacion con la coronariografia

    Energy Technology Data Exchange (ETDEWEB)

    Garcia C, S.E.; Garcia O, R. [Servicio de Medicina Nuclear, Centro Medico ABC, Campis Observatorio, IAP (Mexico)

    2005-07-01

    The attenuation that suffers the radiation in the soft tissues of the hinders the appropriate interpretation of the myocardial perfusion studies, for what have been implemented attenuation correction systems to reduce the attenuation for soft tissues and to provide myocardial perfusion images more accurate in the diagnosis of coronary illness. The objective was to evaluate the utility of an attenuation correction system (with source of Gadolinium 153) to minimize the devices that look like true defects of myocardial perfusion, caused by soft tissues (mammary tissue, thoracic wall, abdomen, left hemi diaphragm), and to compare those interpretations of the studies with the interpretations of the corresponding coronariographies. The method consists of 95 electronic files which were revised with the concept of heart catheterization, being identified 20 patients from the masculine sex to those that underwent coronariography among May 1999 and December 2002, and that they had study of myocardial perfusion in a maximum period of 3 months foresaw to the invasive procedure. (Author)

  9. Arm exercise testing with myocardial scintigraphy in asymptomatic patients with peripheral vascular disease.

    Science.gov (United States)

    Goodman, S; Rubler, S; Bryk, H; Sklar, B; Glasser, L

    1989-04-01

    Arm exercise with myocardial scintigraphy and oxygen consumption determinations was performed by 33 men with peripheral vascular disease, 40 to 74 years of age (group 2). None had evidence of coronary disease. Nineteen age-matched male control subjects (group 1) were also tested to determine the normal endurance and oxygen consumption during arm exercise in their age group and to compare the results with those obtained during a standard treadmill performance. The maximal heart rate, systolic blood pressure, pressure rate product, and oxygen consumption were all significantly lower for arm than for leg exercise. However, there was good correlation between all these parameters for both types of exertion. The maximal heart rate, work load and oxygen consumption were greater for group 1 subjects than in patients with peripheral vascular disease despite similar activity status. None of the group 1 subjects had abnormal arm exercise ECGs, while six members of group 2 had ST segment changes. Thallium-201 scintigraphy performed in the latter group demonstrated perfusion defects in 25 patients. After nine to 29 months of follow-up, three patients who had abnormal tests developed angina and one of them required coronary bypass surgery. Arm exercise with myocardial scintigraphy may be an effective method of detecting occult ischemia in patients with peripheral vascular disease. Those with good exercise tolerance and no electrocardiographic changes or 201T1 defects are probably at lower risk for the development of cardiac complications, while those who develop abnormalities at low exercise levels may be candidates for invasive studies.

  10. MYOCARDIAL PERFUSION ASSESSMENT IN FORECASTING EFFECT OF CORONARY ANGIOPLASTY IN PATIENTS WITH ISCHEMIC CHRONIC HEART FAILURE

    Directory of Open Access Journals (Sweden)

    A. B. Mironkov

    2015-01-01

    Full Text Available Aim. To define influence of the left ventricle (LV perfusion defects on the clinical status dynamics after coronary angioplasty in patients with the expressed myocardium dysfunction of ischemic etiology. Materials and methods. Examined 86 patients (81 men and 5 women aged from 46 to 73 years before and in 2–3 days after percutaneous coronary intervention with diagnosis: CAD, CHF with NYHA class III–IV, echocardiography parameters of LV: ejection fraction less than 40%, end-diastolic volume is more than 200 ml. Perfusion defects of myocardium estimated with use of ECG-gated single photon emission computed tomography. Predictors were defined: perfusion defects on LV apex (in score, perfusion defects in the area of LAD, LCx and RCA (%, the LV global perfusion defects (in score and %. Results. In 42% of cases 6-minute walk test increased to 3 times; The NYHA class decreased by 2 classes (group 1. In 28 cases 6-minute walk test increased to 2 times and the NYHA class decreased on 1 class. In 22 patients 6-minute walk test increased less than 50% of reference values and there was no dynamics NYHA class (50 patients of the group 2. Initial extent of LV global perfusion defects in group 1 – 41,2 ± 4,0%, in group 2 – 58,3 ± 2,4% (р = 0,0004. Similar values are received for perfusion indicators in the area of LAD and the LV apex. Prevalence of myocardial perfusion defects at rest reflects prevalence of a cardiosclerosis in a cardiac muscle. Conclusion. Degree of LV myocardial perfusion defects in patients with the expressed heart failure of ischemic etiology is the key indicator influencing clinical efficiency of coronary angioplasty. Critical size for definition of the favorable forecast of revascularization are 60% and more perfusion defects testifying that in a cardiac muscle the focal cardiosclerosis prevails over the functioning myocardium. 

  11. Early myocardial damage assessment in dystrophinopathies using 99Tcm-MIBI gated myocardial perfusion imaging

    Directory of Open Access Journals (Sweden)

    Zhang L

    2015-12-01

    Full Text Available Li Zhang,1,* Zhe Liu,2,* Ke-You Hu,3 Qing-Bao Tian,3 Ling-Ge Wei,4 Zhe Zhao,5 Hong-Rui Shen,5 Jing Hu5 1Department of Cardiovascular Disorders, 2Department of Geriatrics, The Third Hospital of Hebei Medical University, 3The Public Health Department, Hebei Medical University, 4Department of Nuclear Medicine, 5Department of Neuromuscular Disorders, The Third Hospital of Hebei Medical University, Shijiazhuang, People’s Republic of China *Li Zhang and Zhe Liu are first coauthors of this paper Background: Early detection of muscular dystrophy (MD-associated cardiomyopathy is important because early medical treatment may slow cardiac remodeling and attenuate symptoms of cardiac dysfunction; however, no sensitive and standard diagnostic method for MD at an earlier stage has been well-recognized. Thus, the aim of this study was to test the early diagnostic value of technetium 99m-methoxyisobutylisonitrile (99Tcm-MIBI gated myocardial perfusion imaging (G-MPI for MD.Methods and results: Ninety-one patients underwent 99Tcm-MIBI G-MPI examinations when they were diagnosed with Duchenne muscular dystrophy (DMD (n=77 or Becker muscular dystrophy (BMD; n=14. 99Tcm-MIBI G-MPI examinations were repeated in 43 DMD patients who received steroid treatments for 2 years as a follow-up examination. Myocardial defects were observed in nearly every segment of the left ventricular wall in both DMD and BMD patients compared with controls, especially in the inferior walls and the apices by using 99Tcm-MIBI G-MPI. Cardiac wall movement impairment significantly correlated with age in the DMD and BMD groups (rs=0.534 [P<0.05] and rs=0.784 [P<0.05], respectively. Intermittent intravenous doses of glucocorticoids and continuation with oral steroid treatments significantly improved myocardial function in DMD patients (P<0.05, but not in BMD patients.Conclusion: 99Tcm-MIBI G-MPI is a sensitive and safe approach for early evaluation of cardiomyopathy in patients with DMD or BMD

  12. Peak enhancement ratio of myocardium to aorta for identification of myocardial ischemia using dynamic myocardial computed tomography perfusion imaging.

    Science.gov (United States)

    Tanabe, Yuki; Kido, Teruhito; Kurata, Akira; Yokoi, Takahiro; Fukuyama, Naoki; Uetani, Teruyoshi; Nishiyama, Hikaru; Kawaguchi, Naoto; Tahir, Enver; Miyagawa, Masao; Mochizuki, Teruhito

    2017-12-01

    This study aimed to evaluate the feasibility of peak enhancement (PE) ratio of myocardium to aorta (PER) derived from stress dynamic computed tomography myocardial perfusion imaging (CTP) for the detection of myocardial ischemia assessed by magnetic resonance (MR) imaging. Forty-four patients who underwent stress dynamic CTP and MR imaging were retrospectively evaluated. From the time-attenuation curve, myocardial PE, PER, and myocardial blood flow (MBF) were calculated on a segment-based analysis. The correlation between myocardial and aortic PE was assessed by Spearman's correlation, and the differences in myocardial PE and PER between normal and ischemic myocardium were assessed by the Mann-Whitney U-test. The diagnostic accuracies of myocardial PE, PER, and MBF for detecting myocardial ischemia were compared by receiver operating characteristic analysis. Of 704 segments, 258 segments (37%) were diagnosed as myocardial ischemia with MR imaging. Myocardial and aortic PE were significantly correlated in both normal and ischemic segments (r=0.76 and 0.58; pmyocardial PE and PER of ischemic segments were significantly lower than those of normal segments (pmyocardial PE, 78% (67-88%) and 82% (95% CI, 70-91%) for PER, and 81% (95% CI, 73-87%) and 85% (95% CI, 79-92%) for MBF. There was a significantly larger area under the curve for PER (0.87; 95% CI, 0.84-0.90) and MBF (0.88; 95%CI, 0.85-0.91), compared to myocardial PE (0.75; 95% CI, 0.70-0.79) (pmyocardial ischemia, comparable to that of MBF. Copyright © 2017 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  13. Comparison of two- versus three-dimensional myocardial contrast echocardiography for assessing subendocardial perfusion abnormality after percutaneous coronary intervention in patients with acute myocardial infarction.

    Science.gov (United States)

    Iwakura, Katsuomi; Ito, Hiroshi; Okamura, Atsushi; Kurotobi, Toshiya; Koyama, Yasushi; Date, Motoo; Inoue, Koichi; Nagai, Hiroyuki; Imai, Michio; Arita, Yo; Toyoshima, Yuko; Ozawa, Makito; Fujii, Kenshi

    2007-11-15

    Myocardial contrast echocardiography (MCE) visualizes myocardial perfusion abnormalities after acute myocardial infarction. However, the limited view of 2-dimensional echocardiography reduces its ability to estimate perfusion abnormalities, especially in the subendocardial region. Three-dimensional echocardiography provides images of the left ventricular endocardium directly. This study was conducted to evaluate the ability of 3-dimensional MCE to assess abnormalities of subendocardial perfusion. Intracoronary 2- and 3-dimensional MCE was performed after primary percutaneous coronary intervention in 47 patients with acute myocardial infarction. Myocardial perfusion within the risk area was evaluated as good, poor, or no reflow on 2-dimensional MCE or as good, poor, or no myocardial opacification in endocardium on 3-dimensional MCE. The 2 methods showed different distributions of perfusion patterns: good, poor, and no reflow on 2-dimensional MCE in 31 (66%), 9 (19%), and 7 (15%) patients and good, poor, and no myocardial opacification in endocardium on 3-dimensional MCE in 17 (36%), 16 (34%), and 14 (20%) patients, respectively. Although only 19 patients (61%) with good reflow on 2-dimensional MCE showed myocardial perfusion grade 3 on angiography, 16 of 17 patients (94%) with good myocardial opacification in endocardium on 3-dimensional MCE showed myocardial perfusion grade 3. Although there were no significant differences in peak creatine kinase among the 3 subsets classified by 2-dimensional MCE, peak creatine kinase showed significant differences not only among the 3 groups but also among the subsets classified by 3-dimensional MCE. Classification by 3-dimensional MCE also predicted regional wall motion after 4.6 +/- 2.7 months, with significant differences between each pair of groups, whereas there was significant overlap of these values between the group with poor reflow and other 2 groups by 2-dimensional MCE. In conclusion, 3-dimensional MCE is a feasible

  14. Use of neural networks to improve quality control of interpretations in myocardial perfusion imaging

    DEFF Research Database (Denmark)

    Tagil, K.; Marving, J.; Lomsky, M.

    2008-01-01

    Tc-sestamibi myocardial perfusion scintigraphy. After a training process, the networks were used to select the 20 cases in each region that were more likely to have a false clinical interpretation. These cases, together with 20 control cases in which the networks detected no likelihood of false clinical interpretation...

  15. [Myocardial perfusion scintigraphy. Exact and cost-effective coronary disease imaging - secondary publication

    DEFF Research Database (Denmark)

    Hesse, B.; Petersen, C.L.; Marcassa, C.

    2008-01-01

    Mortality rates due to coronary arterial disease (CAD) have declined as result of improved prevention, diagnosis and management, but CAD remains the leading cause of death. Myocardial perfusion scintigraphy (MPS) provides a cost-effective tool for early detection of CAD in symptomatic individuals...

  16. Clinical value, cost-effectiveness, and safety of myocardial perfusion scintigraphy: a position statement

    DEFF Research Database (Denmark)

    Marcassa, C.; Bax, J.J.; Bengel, F.

    2008-01-01

    Mortality rates due to coronary artery disease (CAD) have declined in recent years as result of improved prevention, diagnosis, and management. Nonetheless, CAD remains the leading cause of death worldwide with most casualties expected to occur in developing nations. Myocardial perfusion scintigr...

  17. Myocardial perfusion scintigraphy in the detection of silent ischemia in asymptomatic diabetic patients

    Energy Technology Data Exchange (ETDEWEB)

    Oki, Glaucia Celeste Rossatto [Clinica Diagnoson and Hospital Aristides Maltez, Salvador, BA (Brazil). Servicos de Medicina Nuclear; Pavin, Elizabeth Joao; Parisi, Maria Candida R. [Universidade Estadual de Campinas (Unicamp), Campinas, SP (Brazil). Department of Internal Medicine. Service of Endocrinology; Coelho, Otavio Rizzi; Almeida, Raitany C. [Universidade Estadual de Campinas (Unicamp), Campinas, SP (Brazil). Department of Internal Medicine. Service of Cardiology; Etchebehere, Elba Cristina Sa de Camargo; Ramos, Celso Dario, E-mail: cdramos@unicamp.br [Universidade Estadual de Campinas (Unicamp), Campinas, SP (Brazil). Department of Radiology. Service of Nuclear Medicine; Camargo, Edwaldo Eduardo [Hospital Sirio-Libanes, Campinas, SP (Brazil). Service of Nuclear Medicine

    2013-01-15

    Objective: This study was aimed to evaluate myocardial perfusion in asymptomatic patients with type 1 (DM1) and type 2 diabetes mellitus (DM2) without previous diagnoses of coronary artery disease (CAD) or cerebral infarction. Materials and Methods: Fifty-nine consecutive asymptomatic patients (16 DM1, 43 DM2) underwent myocardial perfusion scintigraphy with {sup 99m}Tc-sestamibi (MPS). They were evaluated for body mass index, metabolic control of DM, type of therapy, systemic arterial hypertension, dyslipidemia, nephropathy, retinopathy, peripheral neuropathy, smoking, and familial history of CAD. Results: MPS was abnormal in 15 patients (25.4%): 12 (20.3%) with perfusion abnormalities, and 3 with isolated left ventricular dysfunction. The strongest predictors for abnormal myocardial perfusion were: age 60 years and above (p = 0.017; odds ratio [OR] = 6.0), peripheral neuropathy (p = 0.028; OR = 6.1), nephropathy (p = 0.031; OR = 5.6), and stress ECG positive for ischemia (p = 0.049; OR = 4.08). Conclusion: Silent myocardial ischemia occurs in more than one in five asymptomatic diabetic patients. The strongest predictors of ischemia in this study were: patient age, peripheral neuropathy, nephropathy, retinopathy and a stress ECG positive for ischemia. (author)

  18. Normal stress databases in myocardial perfusion scintigraphy – how many subjects do you need?

    DEFF Research Database (Denmark)

    Trägårdh, Elin; Sjöstrand, Karl; Edenbrandt, Lars

    2012-01-01

    Commercial normal stress databases in myocardial perfusion scintigraphy (MPS) commonly consist of 30–40 individuals. The aim of the study was to determine how many subjects are needed. Four normal stress databases were developed using patients who underwent 99mTc MPS: non‐corrected images (NC...

  19. Myocardial perfusion MRI with sliding-window conjugate-gradient HYPR.

    Science.gov (United States)

    Ge, Lan; Kino, Aya; Griswold, Mark; Mistretta, Charles; Carr, James C; Li, Debiao

    2009-10-01

    First-pass perfusion MRI is a promising technique for detecting ischemic heart disease. However, the diagnostic value of the method is limited by the low spatial coverage, resolution, signal-to-noise ratio (SNR), and cardiac motion-related image artifacts. In this study we investigated the feasibility of using a method that combines sliding window and CG-HYPR methods (SW-CG-HYPR) to reduce the acquisition window for each slice while maintaining the temporal resolution of one frame per heartbeat in myocardial perfusion MRI. This method allows an increased number of slices, reduced motion artifacts, and preserves the relatively high SNR and spatial resolution of the "composite images." Results from eight volunteers demonstrate the feasibility of SW-CG-HYPR for accelerated myocardial perfusion imaging with accurate signal intensity changes of left ventricle blood pool and myocardium. Using this method the acquisition time per cardiac cycle was reduced by a factor of 4 and the number of slices was increased from 3 to 8 as compared to the conventional technique. The SNR of the myocardium at peak enhancement with SW-CG-HYPR (13.83 +/- 2.60) was significantly higher (P < 0.05) than the conventional turbo-FLASH protocol (8.40 +/- 1.62). Also, the spatial resolution of the myocardial perfection images was significantly improved. SW-CG-HYPR is a promising technique for myocardial perfusion MRI. (c) 2009 Wiley-Liss, Inc.

  20. EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT

    DEFF Research Database (Denmark)

    Verberne, Hein J; Acampa, Wanda; Anagnostopoulos, Constantinos

    2015-01-01

    Since the publication of the European Association of Nuclear Medicine (EANM) procedural guidelines for radionuclide myocardial perfusion imaging (MPI) in 2005, many small and some larger steps of progress have been made, improving MPI procedures. In this paper, the major changes from the updated ...

  1. Multi-scale parameterisation of a myocardial perfusion model using whole-organ arterial networks

    NARCIS (Netherlands)

    Hyde, Eoin R.; Cookson, Andrew N.; Lee, Jack; Michler, Christian; Goyal, Ayush; Sochi, Taha; Chabiniok, Radomir; Sinclair, Matthew; Nordsletten, David A.; Spaan, Jos; van den Wijngaard, Jeroen P. H. M.; Siebes, Maria; Smith, Nicolas P.

    2014-01-01

    A method to extract myocardial coronary permeabilities appropriate to parameterise a continuum porous perfusion model using the underlying anatomical vascular network is developed. Canine and porcine whole-heart discrete arterial models were extracted from high-resolution cryomicrotome vessel image

  2. EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT: 2015 revision

    NARCIS (Netherlands)

    Verberne, Hein J.; Acampa, Wanda; Anagnostopoulos, Constantinos; Ballinger, Jim; Bengel, Frank; de Bondt, Pieter; Buechel, Ronny R.; Cuocolo, Alberto; van Eck-Smit, Berthe L. F.; Flotats, Albert; Hacker, Marcus; Hindorf, Cecilia; Kaufmann, Philip A.; Lindner, Oliver; Ljungberg, Michael; Lonsdale, Markus; Manrique, Alain; Minarik, David; Scholte, Arthur J. H. A.; Slart, Riemer H. J. A.; Trägårdh, Elin; de Wit, Tim C.; Hesse, Birger

    2015-01-01

    Since the publication of the European Association of Nuclear Medicine (EANM) procedural guidelines for radionuclide myocardial perfusion imaging (MPI) in 2005, many small and some larger steps of progress have been made, improving MPI procedures. In this paper, the major changes from the updated

  3. EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT : 2015 revision

    NARCIS (Netherlands)

    Verberne, Hein J.; Acampa, Wanda; Anagnostopoulos, Constantinos; Ballinger, Jim; Bengel, Frank; De Bondt, Pieter; Buechel, Ronny R.; Cuocolo, Alberto; van Eck-Smit, Berthe L. F.; Flotats, Albert; Hacker, Marcus; Hindorf, Cecilia; Kaufmann, Philip A.; Lindner, Oliver; Ljungberg, Michael; Lonsdale, Markus; Manrique, Alain; Minarik, David; Scholte, Arthur J. H. A.; Slart, Riemer H. J. A.; Tragardh, Elin; de Wit, Tim C.; Hesse, Birger

    2015-01-01

    Since the publication of the European Association of Nuclear Medicine (EANM) procedural guidelines for radionuclide myocardial perfusion imaging (MPI) in 2005, many small and some larger steps of progress have been made, improving MPI procedures. In this paper, the major changes from the updated

  4. Myocardial perfusion scintigraphy in the UK: insights from the British Nuclear Cardiology Society Survey 2000

    OpenAIRE

    KELION, A; Anagnostopoulos, C.; Harbinson, M; Underwood, S; Metcalfe, M.; t for,

    2005-01-01

    Background: The National Institute for Health and Clinical Excellence (NICE) has recently published a very positive technology appraisal of myocardial perfusion scintigraphy (MPS). This has important implications for service provision within the National Health Service, and an accurate knowledge of the current level of MPS activity is necessary.

  5. A decision support system improves the interpretation of myocardial perfusion imaging

    DEFF Research Database (Denmark)

    Tagil, K.; Bondouy, M.; Chaborel, J.P.

    2008-01-01

    PURPOSE: The aim of this study was to investigate the influence of a computer-based decision support system (DSS) on performance and inter-observer variability of interpretations regarding ischaemia and infarction in myocardial perfusion scintigraphy (MPS). METHODS: Seven physicians independently...... physicians can improve their interpretation with the advice from such a system Udgivelsesdato: 2008/9...

  6. Systematic review of cost-effectiveness of myocardial perfusion scintigraphy in patients with ischaemic heart disease

    NARCIS (Netherlands)

    Tragardh, Elin; Tan, Siok Swan; Bucerius, Jan; Gimelli, Alessia; Gaemperli, Oliver; Lindner, Oliver; Agostini, Denis; Uebleis, Christopher; Sciagra, Roberto; Slart, Riemer H.; Underwood, S. Richard; Hyafil, Fabien; Hacker, Marcus; Verberne, Hein J.

    2017-01-01

    Coronary artery disease (CAD) is a major cause of death and disability. Several diagnostic tests, such as myocardial perfusion scintigraphy (MPS), are accurate for the detection of CAD, as well as having prognostic value for the prediction of cardiovascular events. Nevertheless, the diagnostic and

  7. Artifacts in Quantitative analysis of myocardial perfusion SPECT, using Cedars-Sinai QPS Software.

    Science.gov (United States)

    Malek, Hadi; Yaghoobi, Nahid; Hedayati, Raheleh

    2017-04-01

    Quantitative analysis of myocardial perfusion Single photon emission computerized tomography (SPECT) images is increasingly applied in modern nuclear cardiology practice, assisting in the interpretation of myocardial perfusion images (MPI). There are different extensively validated state-of-the-art software packages, including QPS (cedars-Sinai), Corridor 4DM (University of Michigan) and Emory cardiac toolbox (Emory university), providing highly accurate and reproducible data. However, these software packages may suffer from potential artifacts related to patient or technical factors. By recognizing the source of such artifacts, the interpreting physician can avoid misinterpretation of MPI study. In this review, we discuss some of technical pitfalls that may occur in Quantitative Perfusion SPECT software (QPS, cedars-Sinai Medical center).

  8. Adenosine-induced stress myocardial perfusion imaging using dual-source cardiac computed tomography.

    Science.gov (United States)

    Blankstein, Ron; Shturman, Leon D; Rogers, Ian S; Rocha-Filho, Jose A; Okada, David R; Sarwar, Ammar; Soni, Anand V; Bezerra, Hiram; Ghoshhajra, Brian B; Petranovic, Milena; Loureiro, Ricardo; Feuchtner, Gudrun; Gewirtz, Henry; Hoffmann, Udo; Mamuya, Wilfred S; Brady, Thomas J; Cury, Ricardo C

    2009-09-15

    This study sought to determine the feasibility of performing a comprehensive cardiac computed tomographic (CT) examination incorporating stress and rest myocardial perfusion imaging together with coronary computed tomography angiography (CTA). Although cardiac CT can identify coronary stenosis, very little data exist on the ability to detect stress-induced myocardial perfusion defects in humans. Thirty-four patients who had a nuclear stress test and invasive angiography were included in the study. Dual-source computed tomography (DSCT) was performed as follows: 1) stress CT: contrast-enhanced scan during adenosine infusion; 2) rest CT: contrast-enhanced scan using prospective triggering; and 3) delayed scan: acquired 7 min after rest CT. Images for CTA, computed tomography perfusion (CTP), and single-photon emission computed tomography (SPECT) were each read by 2 independent blinded readers. The DSCT protocol was successfully completed for 33 of 34 subjects (average age 61.4 +/- 10.7 years; 82% male; body mass index 30.4 +/- 5 kg/m(2)) with an average radiation dose of 12.7 mSv. On a per-vessel basis, CTP alone had a sensitivity of 79% and a specificity of 80% for the detection of stenosis > or =50%, whereas SPECT myocardial perfusion imaging had a sensitivity of 67% and a specificity of 83%. For the detection of vessels with > or =50% stenosis with a corresponding SPECT perfusion abnormality, CTP had a sensitivity of 93% and a specificity of 74%. The CTA during adenosine infusion had a per-vessel sensitivity of 96%, specificity of 73%, and negative predictive value of 98% for the detection of stenosis > or =70%. Adenosine stress CT can identify stress-induced myocardial perfusion defects with diagnostic accuracy comparable to SPECT, with similar radiation dose and with the advantage of providing information on coronary stenosis.

  9. Does Enhanced External Counterpulsation (EECP Significantly Affect Myocardial Perfusion?: A Systematic Review & Meta-Analysis.

    Directory of Open Access Journals (Sweden)

    Xiaoxia Qin

    Full Text Available Enhanced external counterpulsation (EECP is currently applied for treating coronary artery disease (CAD patients. However, the mechanism(s by which EECP ameliorates angina pectoris and long-term left ventricular function remain largely unknown. The aim of this study will be to assess whether EECP significantly affects myocardial perfusion in CAD patients through a systematic review and meta-analysis of the available literature.MEDLINE, EMBASE, and Cochrane CENTRAL databases were searched for prospective studies on CAD patients that underwent EECP and reported myocardial perfusion data pre- and post-EECP. The impact of EECP was assessed based on the weighted mean difference (WMD in myocardial perfusion from pre-EECP to post-EECP. Statistical heterogeneity was assessed by the I2 index. Publication bias was assessed through visual inspection of the funnel plot as well as Begg's and Egger's testing.Standard EECP therapy (i.e., 35-36 one-hour sessions within a seven-week period significantly increased myocardial perfusion in CAD patients (pooled WMD: -0.19, 95% CI: -0.38 to 0.00, p = 0.049. A random effects analysis was applied on account of significant heterogeneity (I2 = 89.1%, p = 0.000. There was no evidence of significant publication bias (Begg's p = 0.091; Egger's p = 0.282.Standard EECP therapy significantly increases myocardial perfusion in CAD patients. This study's findings support the continued use of standard EECP therapy in CAD patients and provides one putative physiological mechanism to help explain the improvements in angina pectoris and long-term left ventricular function observed in CAD patients after EECP therapy.

  10. Effect of myocardial perfusion and metabolic interventions on cardiac kinetics of phenylpentadecanoic acid (IPPA) I 123.

    Science.gov (United States)

    Reske, S N; Schön, S; Schmitt, W; Machulla, H J; Knopp, R; Winkler, C

    1986-01-01

    The effect of regional myocardial perfusion and flow-independent adrenergic stimulation, as well as lactate-mediated inhibition of cardiac lipolysis, on cardiac IPPA uptake and metabolism was examined in canine hearts (flow studies) and in the isolated perfused Langendorff rat heart (metabolic interventions). In both normal and ischaemic myocardium, local perfusion is a major determinant of cardiac IPPA uptake. In pacing-induced hyperaemia, the strict flow-dependence of cardiac IPPA uptake is not preserved. Adrenergic stimulation raises the rate of oxidation of both palmitic acid 14C and IPPA. This change is reflected by increased metabolite production released into the perfusate and radioactivity clearance recorded externally. Lactate in high concentrations exerts the opposite effect on cardiac free fatty acid oxidation. IPPA is stored in this condition preferentially in tissue phospholipids and triglycerides.

  11. Scintigraphic assessment of sympathetic innervation after transmural versus nontransmural myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Dae, M.W.; Herre, J.M.; O' Connell, J.W.; Botvinick, E.H.; Newman, D.; Munoz, L. (University of California, San Francisco (USA))

    1991-05-01

    To evaluate the feasibility of detecting denervated myocardium in the infarcted canine heart, the distribution of sympathetic nerve endings using I-123 metaiodobenzylguanidine (MIBG) was compared with the distribution of perfusion using thallium-201, with the aid of color-coded computer functional map in 16 dogs. Twelve dogs underwent myocardial infarction by injection of vinyl latex into the left anterior descending coronary artery (transmural myocardial infarction, n = 6), or ligation of the left anterior descending coronary artery (nontransmural myocardial infarction, n = 6). Four dogs served as sham-operated controls. Image patterns were compared with tissue norepinephrine content and with histofluorescence microscopic findings in biopsy specimens. Hearts with transmural infarction showed zones of absent MIBG and thallium, indicating scar. Adjacent and distal regions showed reduced MIBG but normal thallium uptake, indicating viable but denervated myocardium. Denervation distal to infarction was confirmed by reduced norepinephrine content and absence of nerve fluorescence. Nontransmural myocardial infarction showed zones of wall thinning with decreased thallium uptake and a greater reduction or absence of MIBG localized to the region of the infarct, with minimal extension of denervation beyond the infarct. Norepinephrine content was significantly reduced in the infarct zone, and nerve fluorescence was absent. These findings suggest that (1) MIBG imaging can detect viable and perfused but denervated myocardium after infarction; and (2) as opposed to the distal denervation produced by transmural infarction, nontransmural infarction may lead to regional ischemic damage of sympathetic nerves, but may spare subepicardial nerve trunks that course through the region of infarction to provide a source of innervation to distal areas of myocardium.

  12. Scintigraphic assessment of sympathetic innervation after transmural versus nontransmural myocardial infarction.

    Science.gov (United States)

    Dae, M W; Herre, J M; O'Connell, J W; Botvinick, E H; Newman, D; Munoz, L

    1991-05-01

    To evaluate the feasibility of detecting denervated myocardium in the infarcted canine heart, the distribution of sympathetic nerve endings using I-123 metaiodobenzylguanidine (MIBG) was compared with the distribution of perfusion using thallium-201, with the aid of color-coded computer functional map in 16 dogs. Twelve dogs underwent myocardial infarction by injection of vinyl latex into the left anterior descending coronary artery (transmural myocardial infarction, n = 6), or ligation of the left anterior descending coronary artery (nontransmural myocardial infarction, n = 6). Four dogs served as sham-operated controls. Image patterns were compared with tissue norepinephrine content and with histofluorescence microscopic findings in biopsy specimens. Hearts with transmural infarction showed zones of absent MIBG and thallium, indicating scar. Adjacent and distal regions showed reduced MIBG but normal thallium uptake, indicating viable but denervated myocardium. Denervation distal to infarction was confirmed by reduced norepinephrine content and absence of nerve fluorescence. Nontransmural myocardial infarction showed zones of wall thinning with decreased thallium uptake and a greater reduction or absence of MIBG localized to the region of the infarct, with minimal extension of denervation beyond the infarct. Norepinephrine content was significantly reduced in the infarct zone, and nerve fluorescence was absent. These findings suggest that 1) MIBG imaging can detect viable and perfused but denervated myocardium after infarction; and 2) as opposed to the distal denervation produced by transmural infarction, nontransmural infarction may lead to regional ischemic damage of sympathetic nerves, but may spare subepicardial nerve trunks that course through the region of infarction to provide a source of innervation to distal areas of myocardium.

  13. Image registration and analysis for quantitative myocardial perfusion: application to dynamic circular cardiac CT

    Science.gov (United States)

    Isola, A. A.; Schmitt, H.; van Stevendaal, U.; Begemann, P. G.; Coulon, P.; Boussel, L.; Grass, M.

    2011-09-01

    Large area detector computed tomography systems with fast rotating gantries enable volumetric dynamic cardiac perfusion studies. Prospectively, ECG-triggered acquisitions limit the data acquisition to a predefined cardiac phase and thereby reduce x-ray dose and limit motion artefacts. Even in the case of highly accurate prospective triggering and stable heart rate, spatial misalignment of the cardiac volumes acquired and reconstructed per cardiac cycle may occur due to small motion pattern variations from cycle to cycle. These misalignments reduce the accuracy of the quantitative analysis of myocardial perfusion parameters on a per voxel basis. An image-based solution to this problem is elastic 3D image registration of dynamic volume sequences with variable contrast, as it is introduced in this contribution. After circular cone-beam CT reconstruction of cardiac volumes covering large areas of the myocardial tissue, the complete series is aligned with respect to a chosen reference volume. The results of the registration process and the perfusion analysis with and without registration are evaluated quantitatively in this paper. The spatial alignment leads to improved quantification of myocardial perfusion for three different pig data sets.

  14. Quantitative three-dimensional evaluation of myocardial perfusion during regadenoson stress using multidetector computed tomography.

    Science.gov (United States)

    Mor-Avi, Victor; Lodato, Joseph A; Kachenoura, Nadjia; Chandra, Sonal; Freed, Benjamin H; Newby, Barbara; Lang, Roberto M; Patel, Amit R

    2012-01-01

    The ability of multidetector computed tomography (MDCT) to detect stress-induced myocardial perfusion abnormalities is of great clinical interest as a potential tool for the combined evaluation of coronary stenosis and its hemodynamic significance. We tested the hypothesis that quantitative 3-dimensional (3D) analysis of myocardial perfusion from MDCT images obtained during regadenoson stress would more accurately detect the presence of significant coronary artery disease (CAD) than identical analysis when performed on resting MDCT images. We prospectively studied 50 consecutive patients referred for CT coronary angiography (CTCA) who agreed to undergo additional imaging with regadenoson (0.4 mg; Astellas). Images were acquired using prospective gating (256-channel; Philips). Custom analysis software was used to define 3D myocardial segments, and calculate for each segment an index of severity and extent of perfusion abnormality, Qh, which was compared with perfusion defects predicted by the presence and severity of coronary stenosis on CTCA. Three patients were excluded because of image artifacts. In the remaining 47 patients, CTCA depicted stenosis more than 50% in 23 patients in 37 of 141 coronary arteries. In segments supplied by the obstructed arteries, myocardial attenuation was slightly reduced compared with normally perfused segments at rest (mean [SD], 91 [21] vs 93 [26] Hounsfield units, not significant) and, to a larger extent, at peak stress (102 [21] vs 112 [20] Hounsfield units, P regadenoson improved the diagnosis of CAD, as reflected by an increase in sensitivity (from 0.57 to 0.91) and improvement in accuracy (from 0.65 to 0.77). Quantitative 3D analysis of MDCT images allows objective detection of CAD, the accuracy of which is improved by regadenoson stress.

  15. Correlation of myocardial perfusion SPECT with invasive and computed tomography coronary angiogram.

    Science.gov (United States)

    Shelley, S; Indirani, M; Sathyamurthy, I; Subramanian, K; Priti, N; Harshad, K; Padma, D

    2012-01-01

    The consequences of atherosclerosis can be detected by multislice computed tomography (MSCT), invasive coronary angiogram (CAG) and the resultant myocardial ischaemia by myocardial perfusion single photon emission computed tomography (MPS). In this study an attempt is made to compare MSCT with MPS and also to compare the MSCT findings with that of invasive CAG in patients suspected to have coronary artery disease (CAD). A total of 99 patients suspected to have CAD underwent both MSCT and MPS with (99m)Tc sestamibi. The MSCT studies were classified as having no CAD, significant CAD (>50% diameter stenosis), and insignificant CAD (50% diameter stenosis). Multislice computed tomography correlated well in 46 (84%) with P value of 800). Myocardial perfusion single photon emission computed tomography was normal in 15 (27%) coronaries. Myocardial perfusion single photon emission computed tomography provides functional information of the anatomical lesions and MSCT provides anatomical information. Both are two different diagnostic modalities. The MSCT has high NPV in patients with less likelihood for CAD. When compared with CAG, the correlation with MSCT was good and is useful where the calcium score is low. Copyright © 2012 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  16. Effects of aortic tortuosity on left ventricular diastolic parameters derived from gated myocardial perfusion single photon emission computed tomography in patients with normal myocardial perfusion.

    Science.gov (United States)

    Kurisu, Satoshi; Nitta, Kazuhiro; Sumimoto, Yoji; Ikenaga, Hiroki; Ishibashi, Ken; Fukuda, Yukihiro; Kihara, Yasuki

    2017-12-05

    Aortic tortuosity is often found on chest radiograph, especially in aged patients. We tested the hypothesis that aortic tortuosity was associated with LV diastolic parameters derived from gated SPECT in patients with normal myocardial perfusion. One-hundred and twenty-two patients with preserved LV ejection fraction and normal myocardial perfusion were enrolled. Descending aortic deviation was defined as the horizontal distance from the left line of the aortic knob to the most prominent left line of the descending aorta. This parameter was measured for the quantitative assessment of aortic tortuosity. Peak filling rate (PFR) and one-third mean filling rate (1/3 MFR) were obtained from redistribution images as LV diastolic parameters. Descending aortic deviation ranged from 0 to 22 mm with a mean distance of 4.5 ± 6.3 mm. Descending aortic deviation was significantly correlated with age (r = 0.38, p < 0.001) and estimated glomerular filtration rate (eGFR) (r = - 0.21, p = 0.02). Multivariate linear regression analysis revealed that eGFR (β = 0.23, p = 0.02) and descending aortic deviation (β = - 0.23, p = 0.01) were significantly associated with PFR, and that only descending aortic deviation (β = - 0.21, p = 0.03) was significantly associated with 1/3 MFR. Our data suggest that aortic tortuosity is associated with LV diastolic parameters derived from gated SPECT in patients with normal myocardial perfusion.

  17. A new clinical tool for the quantification of myocardial CT perfusion imaging in patients with suspected Ischemic Heart Disease

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz Muñoz, A.; Dux-Santoy Hurtado, L.; Rodriguez Palomares, J.L.; Piella Fenoy, G.

    2016-07-01

    In the clinical practice, the evaluation of myocardial perfusion by using Computed Tomography (CT) Imaging is usually performed visually or semi-quantitatively. The scarcity of quantitative perfusion data not always allows a proper diagnose of patients which are suspected of suffering from some diseases, such as Ischemic Heart Disease (IHD). In this work, a clinical tool for the automatic quantification of myocardial perfusion in patients with suspected IHD is proposed. Myocardial perfusion is assessed based on a combined diagnosis protocol (CT/CTP protocol) which involves the acquisition of two contrastenhanced CT images, one obtained at rest and another acquired under pharmacological stress. The clinical tool allows the automatic quantification of perfusion in different myocardial segments defined according to the 16-AHA-segmentation model of the left ventricle, by providing the mean of Hounsfield Units in those regions. Based on this analysis, the clinicians can compare the values at baseline and at hyperemia, and they can better determine hypoperfusion defects in patients with IHD. The validation of the clinical tool was performed by comparing automatic and manual perfusion measurements of 10 patients with suspected IHD who were previously assessed with Single Photon Emission Computed Tomography (SPECT) for perfusion analysis. A strong linear correlation was found between the automatic and manual results. Afterwards, perfusion defects obtained from CT/CTP protocol were compared to perfusion defects from SPECT, to assess the applicability of this clinical tool for the diagnosis of IHD. (Author)

  18. Estimate of myocardial salvage in late presentation acute myocardial infarction by comparing functional and perfusion abnormalities in predischarge gated SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Sotgia, Barbara; Sciagra, Roberto; Pupi, Alberto [University of Florence, Nuclear Medicine Unit, Department of Clinical Physiopathology, Florence (Italy); Parodi, Guido; Antoniucci, David [Careggi Hospital, Division of Cardiology, Florence (Italy); Kastrati, Adnan; Schoemig, Albert [Technische Universitaet, Deutsches Herzzentrum, Munich (Germany)

    2008-05-15

    We hypothesized that, because of persistent stunning, the extent of post-treatment functional abnormalities detected using gated single-photon emission computed tomography (SPECT) could be representative of the initial risk area in acute myocardial infarction (AMI) treated by reperfusion therapy. In 48 AMI patients, we acquired two {sup 99m}Tc-sestamibi gated SPECT studies (at admission with tracer injection before treatment and at discharge 5 to 10 days later). We assessed the myocardial salvage defined by the admission minus predischarge summed rest score, and we compared it with the value obtained by subtracting the extent of perfusion defect from the extent of wall motion or wall thickening abnormalities in predischarge gated SPECT. Myocardial salvage was expressed as salvage index (salvaged myocardium divided by initial risk area). There was a good correlation between summed rest score salvage index and wall motion (Spearman's {rho} = 0.754, p < 0.0001) or wall thickening salvage index (Spearman's {rho} = 0.798, p < 0.0001). The wall thickening salvage index was able to classify correctly the patients that had a summed rest score salvage index {>=} 0.10 with 73% sensitivity, 88% specificity, and 83% accuracy. The wall motion salvage index was highly sensitive (91%) but poorly specific (13%, p < 0.002 vs wall thickening salvage index) and less accurate (69%, p < 0.05 vs wall thickening salvage index). {sup 99m}Tc-sestamibi gated SPECT allows assessing myocardial salvage using only post-treatment data. The salvage index derived using wall thickening as surrogate of admission perfusion defect correlates well with the salvage index measured by comparing pre- and post-treatment perfusion defects. (orig.)

  19. Myocardial perfusion in patients with non-ischaemic systolic heart failure and type 2 diabetes

    DEFF Research Database (Denmark)

    Byrne, Christina; Hasbak, Philip; Kjaer, Andreas

    2017-01-01

    Both patients with non-ischaemic systolic heart failure and patients with type 2 diabetes (T2DM) often have reduced myocardial blood flow without significant coronary atherosclerosis. However, the mechanisms are not fully understood. The aim of this study was to investigate whether perfusion...... is reduced additionally when the 2 are combined. In a cross-sectional study, we scanned patients with non-ischaemic systolic heart failure with and without T2DM using Rubidium-82 positron emission tomography/computed tomography at rest and adenosine-induced stress, thereby obtaining the myocardial flow...... reserve (myocardial flow reserve (MFR) = stress flow/rest flow) as a measure of the myocardial vasomotor function; 28 patients with T2DM and 123 without T2DM were included. All patients received heart failure treatment according to guidelines. Multiple regression analysis was performed to assess...

  20. Myocardial perfusion analysis in cardiac computed tomography angiographic images at rest.

    Science.gov (United States)

    Xiong, Guanglei; Kola, Deeksha; Heo, Ran; Elmore, Kimberly; Cho, Iksung; Min, James K

    2015-08-01

    Cardiac computed tomography angiography (CTA) is a non-invasive method for anatomic evaluation of coronary artery stenoses. However, CTA is prone to artifacts that reduce the diagnostic accuracy to identify stenoses. Further, CTA does not allow for determination of the physiologic significance of the visualized stenoses. In this paper, we propose a new system to determine the physiologic manifestation of coronary stenoses by assessment of myocardial perfusion from typically acquired CTA images at rest. As a first step, we develop an automated segmentation method to delineate the left ventricle. Both endocardium and epicardium are compactly modeled with subdivision surfaces and coupled by explicit thickness representation. After initialization with five anatomical landmarks, the model is adapted to a target image by deformation increments including control vertex displacements and thickness variations guided by trained AdaBoost classifiers, and regularized by a prior of deformation increments from principal component analysis (PCA). The evaluation using a 5-fold cross-validation demonstrates the overall segmentation error to be 1.00 ± 0.39 mm for endocardium and 1.06 ± 0.43 mm for epicardium, with a boundary contour alignment error of 2.79 ± 0.52. Based on our LV model, two types of myocardial perfusion analyzes have been performed. One is a perfusion network analysis, which explores the correlation (as network edges) pattern of perfusion between all pairs of myocardial segments (as network nodes) defined in AHA 17-segment model. We find perfusion network display different patterns in the normal and disease groups, as divided by whether significant coronary stenosis is present in quantitative coronary angiography (QCA). The other analysis is a clinical validation assessment of the ability of the developed algorithm to predict whether a patient has significant coronary stenosis when referenced to an invasive QCA ground truth standard. By training three machine

  1. The limited role of myocardial fluorine-18 fluorodeoxyglucose imaging in candidates for cardiac transplantation. A planar imaging study

    Energy Technology Data Exchange (ETDEWEB)

    Kalff, V.; Van Every, B.; Kelly, M.J. [Alfred Hospital, Prahran, VIC (Australia). Dept. of Nuclear Medicine; Barton, H.J.; Bergin, P.J.; Esmore, D.S. [Alfred Hospital, Prahran, VIC (Australia). Cardiac Transplantation Services; Berlangieri, S.U. [Austin Hospital, Heidelberg, VIC (Australia). Centre for Positron Emission Tomography

    1998-03-01

    This study compares the incidence and extent of hibernating myocardium (defined by myocardial perfusion/metabolism mismatch) in 28 cardiac transplant candidates with ischaemic cardiomyopathy and in 16 other patients with coronary artery disease (CAD) undergoing viability assessment. It then reviews the impact of myocardial perfusion metabolism imaging on management decisions in the transplant candidates at 6 months after scintigraphy. Each patient underwent a planar myocardial thallium-201 and fluorine-18 fluorodeoxyglucose scan on a modified gamma camera. Perfusion/metabolism mismatch was sized semi-quantitatively and each patient was assigned a global mismatch score. Transplant candidates had a lower left ventricular ejection fraction (LVEF) (P<0.0002) and extent of hibernating myocardium (lower global mismatch score: P=0.005) than other CAD patients but the difference in respect of mismatch frequency (8/28 vs 9/16 patients) did not reach statistical significance. Transplant candidates with LVEF <20% had a lower global mismatch score (P<0.02) than those with an LVEF {>=}20%. Interestingly, two of three other CAD patients with LVEF <20% had a moderate mismatch. Follow-up studies revealed the lack of impact of metabolic imaging as none of the three transplant candidates who eventually underwent revascularisation had hibernating myocardium and transplantation was offered to one of only two candidates with more than one minor mismatch. Thus metabolic imaging in potential transplant candidates may be of limited value because of the very low extent of hibernating myocardium, particularly if LVEF is below 20% and where clinical decisions are often based on many other factors. (orig.)

  2. Quantitative Myocardial Perfusion with Dynamic Contrast-Enhanced Imaging in MRI and CT : Theoretical Models and Current Implementation

    NARCIS (Netherlands)

    Pelgrim, G J; Handayani, A; Dijkstra, H; Prakken, N H J; Slart, R H J A; Oudkerk, M; Van Ooijen, P M A; Vliegenthart, R; Sijens, P E

    2016-01-01

    Technological advances in magnetic resonance imaging (MRI) and computed tomography (CT), including higher spatial and temporal resolution, have made the prospect of performing absolute myocardial perfusion quantification possible, previously only achievable with positron emission tomography (PET).

  3. Effects of diltiazem on myocardial perfusion abnormalities during exercise in patients with hypertrophic cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Sugihara, Hiroki; Taniguchi, Yoko; Ito, Kazuki [Kyoto Prefectural Univ. of Medicine (Japan)] [and others

    1998-12-01

    The effect of diltiazem on myocardial ischemia in patients with hypertrophic cardiomyopathy (HCM) was evaluated by exercise myocardial {sup 201}Tl single photon emission computed tomography (SPECT). Exercise myocardial SPECT was performed before and 8 weeks after oral administration of diltiazem (180 mg/day) in 20 patients with HCM who showed transient perfusion defects on exercise myocardial {sup 201}Tl SPECT under control conditions. SPECT images were divided into 17 segments. The {sup 201}Tl perfusion defects were visually scored and evaluated as the defect score. The transient dilation index was calculated as an index of subendocardial ischemia. Improvement of the defect score was demonstrated in 15 patients after the administration of diltiazem. The mean defect score decreased significantly from 9.90{+-}5.17 to 5.50{+-}4.89 (p<0.0001). Although 16 of 20 patients showed an abnormal transient dilation index before diltiazem treatment, 16 showed improvement and 13 of these normalized after diltiazem therapy. The mean transient dilation index decreased from 1.16{+-}0.10 to 1.02{+-}0.09 (p<0.0001). In conclusion, diltiazem prevents or diminishes myocardial ischemia in patients with HCM. (author)

  4. A randomized, multicenter, multivendor study of myocardial perfusion imaging with regadenoson CT perfusion vs single photon emission CT.

    Science.gov (United States)

    Cury, Ricardo C; Kitt, Therese M; Feaheny, Kathleen; Blankstein, Ron; Ghoshhajra, Brian B; Budoff, Matthew J; Leipsic, Jonathon; Min, James K; Akin, Jamie; George, Richard T

    2015-01-01

    Myocardial CT perfusion (CTP) is a promising tool for the detection of myocardial ischemia. We hypothesize that regadenoson CTP is noninferior to regadenoson single photon emission CT (SPECT) for detecting or excluding myocardial ischemia. Patients (men ≥ 45 years; women ≥ 50 years) with known or suspected coronary artery disease (n = 124) were randomized to 1 of 2 diagnostic sequences: rest and regadenoson SPECT on day 1, then regadenoson CTP and rest CTP (and coronary CT angiography [CTA]) (CTA; same acquisition) on day 2 or regadenoson CTP and rest CTP (and CTA) on Day 1, then rest and regadenoson SPECT on day 2. Scanning platforms included 64-, 128-, 256-, and 320-slice systems. The primary analysis examined the agreement rate between CTP and SPECT for detecting or excluding reversible ischemia in ≥ 2 myocardial segments as assessed by independent, blinded readers. Complete and interpretable CTP and SPECT scans were obtained for 110 patients. Regadenoson CTP was noninferior to SPECT for detecting or excluding reversible ischemia with an agreement rate of 0.87 (95% confidence interval [CI], 0.77-0.97) and sensitivity and specificity of 0.90 (95% CI, 0.71-1.00) and 0.84 (95% CI, 0.77-0.91), respectively. The agreement rate for detecting or excluding ≥ 1 fixed defects by regadenoson CTP and SPECT was 0.86 (95% CI, 0.74-0.98). With SPECT as the reference standard, the diagnostic accuracies for detecting or excluding ischemia by regadenoson CTP and CTA alone were 0.85 (95% CI, 0.78-0.91) and 0.69 (95% CI, 0.60-0.77), respectively. This study establishes the noninferiority of regadenoson CTP to SPECT for detecting or excluding myocardial ischemia. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  5. Caffeine intake inverts the effect of adenosine on myocardial perfusion during stress as measured by T1 mapping

    OpenAIRE

    Kuijpers, Dirkjan; Prakken, Niek H.; Vliegenthart, Rozemarijn; van Dijkman, Paul R. M.; Van der Harst, Pim; Oudkerk, Matthijs

    2016-01-01

    Caffeine intake before adenosine stress myocardial perfusion imaging may cause false negative findings. We hypothesized that the antagonistic effect of caffeine can be measured by T1 relaxation times in rest and adenosine stress cardiac magnetic resonance imaging (CMR), as T1 mapping techniques are sensitive to changes in myocardial blood volume. We prospectively analyzed 105 consecutive patients with adenosine stress perfusion CMR on a 1.5-T MRI system. Rest and stress T1 mapping was perform...

  6. Comparison of Myocardial Contrast Echocardiography Versus Rest Sestamibi Myocardial Perfusion Imaging in the Early Diagnosis of Acute Coronary Syndrome

    Science.gov (United States)

    Kang, Soo-Jin; Song, Jong-Min; Song, Jae-Kwan; Park, Seong-Wook; Park, Seung-Jung

    2010-01-01

    Background It remains unclear whether myocardial contrast echocardiography (MCE) is as accurate as myocardial perfusion imaging with technetium-99m sestamibi (MPI) for the diagnosis of acute coronary syndrome (ACS). We sought to directly compare the diagnostic accuracy of MCE with resting MPI in a head-to-head fashion. Methods We prospectively enrolled 98 consecutive patients (mean age; 59±9 years, 68 males) who presented to the emergency department with chest pain suggestive of acute myocardial ischemia. Early MCE was performed by using continuous infusion of perfluorocarbon-exposed sonicated dextrose albumin (PESDA) during intermittent power Doppler harmonic imaging. Myocardial perfusion defects observed in at least one coronary territory were considered positive. Sestamibi was injected immediately after MCE and MPI was obtained within 6 hours of tracer injection. Results ACS was confirmed in 67 patients. There were 32 patients with acute myocardial infarction (AMI) and 35 patients with unstable angina requiring urgent revascularization. The sensitivities of MCE and MPI for the diagnosis of ACS were 72% and 61%, respectively, which were significantly higher than those of ST segment change (24%, p<0.001 vs. MCE and vs. MPI) and troponin I (27%, p<0.001 vs. MCE and vs. MPI), with similar specificities of 90% to 100%. On a receiveroperating characteristics curve demonstrating diagnostic accuracy for ACS, the area under the curve of MCE was significantly larger than that of MPI (0.86 vs. 0.77, respectively; p=0.019). Conclusion MCE and MPI overcome the low sensitivity of routine triage tests for detecting ACS, and MCE is more accurate than MPI for the diagnosis of ACS in the emergency department. PMID:20706568

  7. Detection of serial changes in absolute myocardial perfusion with 82Rb PET.

    Science.gov (United States)

    deKemp, R A; Ruddy, T D; Hewitt, T; Dalipaj, M M; Beanlands, R S

    2000-08-01

    Serial changes in myocardial perfusion may represent an important marker of disease progression or regression or the effects of therapy for patients with coronary artery disease (CAD). Quantitative methods have not been developed for the assessment of serial changes in perfusion. The objective of this study was to use receiver operator characteristic (ROC) analysis to determine the sensitivity and specificity of direct paired comparisons (DPCs) to detect changes in absolute myocardial perfusion measured with 82Rb PET. Repeated dynamic 82Rb PET scans were obtained on 8 dogs at rest and during hyperemia induced with dobutamine (n = 4) or atrial pacing (n = 4). Radiolabeled microspheres were used to verify perfusion changes. Polar maps of absolute 82Rb retention and associated SD were estimated from the dynamic images. Paired comparisons were then performed using a t test on each of the 532 polar map sectors. Rest-rest and stress-stress differences were used to assess specificity and reproducibility, and stress-rest differences were used to assess sensitivity. 82Rb retention differences of 20% over baseline were detected with 85%-90% sensitivity and specificity, using the optimal DPC probability value and image smoothness. The average 82Rb retention differences correlated well with microspheres (r = 0.74; P = 0.001). Reproducibility of the mean retention values was 4.7% +/- 2.1%. As reproducibility varies, the DPC probability value can be adjusted to maintain specificity. These ROC results are directly applicable to other image modalities that produce measurements with similar SEs (3.7% +/- 0.9%). The developed method of DPCs is sensitive and specific for the detection of changes in absolute myocardial perfusion measured with 82Rb PET.

  8. Three dimensional first-pass myocardial perfusion imaging at 3T: feasibility study

    Directory of Open Access Journals (Sweden)

    Pohost Gerald M

    2008-12-01

    Full Text Available Abstract Background In patients with ischemic heart disease, accurate assessment of the extent of myocardial perfusion deficit may be important in predicting prognosis of clinical cardiac outcomes. The aim of this study was to compare the ability of three dimensional (3D and of two dimensional (2D multi-slice myocardial perfusion imaging (MPI using cardiovascular magnetic resonance (CMR in determining the size of defects, and to demonstrate the feasibility of 3D MPI in healthy volunteers at 3 Tesla. Methods A heart phantom was used to compare the accuracy of 3D and 2D multi-slice MPI in estimating the volume fraction of seven rubber insets which simulated transmural myocardial perfusion defects. Three sets of cross-sectional planes were acquired for 2D multi-slice imaging, where each set was shifted along the partition encoding direction by ± 10 mm. 3D first-pass contrast-enhanced (0.1 mmol/kg Gd-DTPA MPI was performed in three volunteers with sensitivity encoding for six-fold acceleration. The upslope of the myocardial time-intensity-curve and peak SNR/CNR values were calculated. Results Mean/standard deviation of errors in estimating the volume fraction across the seven defects were -0.44/1.49%, 2.23/2.97%, and 2.59/3.18% in 3D, 2D 4-slice, and 2D 3-slice imaging, respectively. 3D MPI performed in healthy volunteers produced excellent quality images with whole left ventricular (LV coverage. Peak SNR/CNR was 57.6 ± 22.0/37.5 ± 19.7 over all segments in the first eight slices. Conclusion 3D performed better than 2D multi-slice MPI in estimating the size of perfusion defects in phantoms. Highly accelerated 3D MPI at 3T was feasible in volunteers, allowing whole LV coverage with excellent image quality and high SNR/CNR.

  9. Optimization and comparison of simultaneous and separate acquisition protocols for dual isotope myocardial perfusion SPECT

    OpenAIRE

    Ghaly, Michael; Links, Jonathan M.; Frey, Eric C.

    2015-01-01

    Dual-isotope simultaneous-acquisition (DISA) rest-stress myocardial perfusion SPECT (MPS) protocols offer a number of advantages over separate acquisition. However, crosstalk contamination due to scatter in the patient and interactions in the collimator degrade image quality. Compensation can reduce the effects of crosstalk, but does not entirely eliminate image degradations. Optimizing acquisition parameters could further reduce the impact of crosstalk. In this paper we investigate the optim...

  10. Quantification of myocardial perfusion using free-breathing MRI and prospective slice tracking

    DEFF Research Database (Denmark)

    Pedersen, Henrik; Kelle, Sebastian; Ringgaard, Steffen

    2009-01-01

    Quantification of myocardial perfusion using first-pass magnetic resonance imaging (MRI) is hampered by respiratory motion of the heart. Prospective slice tracking (PST) potentially overcomes this problem, and may provide an attractive alternative or supplement to current breath-hold techniques. ...... on this field strength constituted a major source of error and needs further improvement to increase the accuracy and robustness of the method....

  11. Myocardial stress perfusion magnetic resonance: initial experience in a pediatric and young adult population using regadenoson.

    Science.gov (United States)

    Noel, Cory V; Krishnamurthy, Ramkumar; Moffett, Brady; Krishnamurthy, Rajesh

    2017-03-01

    Dipyridamole and adenosine are traditional pharmacological stressors for myocardial perfusion. Regadenoson, a selective adenosine A2A agonist, has a lower side effect profile with lower incidence of bronchospasm and bradycardia. There is a growing need for myocardial perfusion assessment within pediatrics. There is no report on the utility of regadenoson as a stress agent in children. To observe the safety and feasibility of regadenoson as a pharmacologic stressor for perfusion cardiac MR in a pilot cohort of pediatric patients weighing more than 40 kg who have congenital heart disease and pediatric acquired heart disease. We reviewed our initial experience with regadenoson stress cardiac MR in 31 pediatric patients 15.8 ± 1.7 years (range 12-22 years) with congenital heart disease and acquired heart disease. Mean patient weight was 60 ± 15 kg (range of 40-93 kg). All patients underwent cardiac MR because of concern for ischemia. The cohort included a heterogeneous group of patients at a pediatric institution with potential risk for ischemia. Subjects' heart rate and blood pressure were monitored and pharmacologic stress was induced by injection of 400 mcg of regadenoson. We evaluated their hemodynamic response and adverse effects using changes in vital signs and onset of symptoms. A pediatric cardiologist and radiologist qualitatively assessed myocardial perfusion and viability images. One child was unable to complete the stress perfusion portion of the examination, but did complete the remaining portion of the CMR. Resting heart rate was 72 ± 14 beats per minute (bpm) and rose to peak of 124 ± 17 bpm (95 ± 50% increase, P regadenoson. Image quality was considered good or diagnostic in all cases. Three patients had irreversible perfusion defects. Four patients had reversible perfusion defects. Nine of the patients underwent cardiac catheterization with angiography and the findings showed excellent agreement. Regadenoson might be a

  12. Myocardial stress perfusion magnetic resonance: initial experience in a pediatric and young adult population using regadenoson

    Energy Technology Data Exchange (ETDEWEB)

    Noel, Cory V. [Baylor College of Medicine, Department of Pediatric Cardiology, Houston, TX (United States); Texas Children' s Hospital, Department of Pediatric Cardiology, Houston, TX (United States); Krishnamurthy, Ramkumar; Krishnamurthy, Rajesh [Texas Children' s Hospital, Department of Radiology, Houston, TX (United States); Moffett, Brady [Texas Children' s Hospital, Department of Pharmacology, Houston, TX (United States)

    2017-03-15

    Dipyridamole and adenosine are traditional pharmacological stressors for myocardial perfusion. Regadenoson, a selective adenosine A2A agonist, has a lower side effect profile with lower incidence of bronchospasm and bradycardia. There is a growing need for myocardial perfusion assessment within pediatrics. There is no report on the utility of regadenoson as a stress agent in children. To observe the safety and feasibility of regadenoson as a pharmacologic stressor for perfusion cardiac MR in a pilot cohort of pediatric patients weighing more than 40 kg who have congenital heart disease and pediatric acquired heart disease. We reviewed our initial experience with regadenoson stress cardiac MR in 31 pediatric patients 15.8 ± 1.7 years (range 12-22 years) with congenital heart disease and acquired heart disease. Mean patient weight was 60 ± 15 kg (range of 40-93 kg). All patients underwent cardiac MR because of concern for ischemia. The cohort included a heterogeneous group of patients at a pediatric institution with potential risk for ischemia. Subjects' heart rate and blood pressure were monitored and pharmacologic stress was induced by injection of 400 mcg of regadenoson. We evaluated their hemodynamic response and adverse effects using changes in vital signs and onset of symptoms. A pediatric cardiologist and radiologist qualitatively assessed myocardial perfusion and viability images. One child was unable to complete the stress perfusion portion of the examination, but did complete the remaining portion of the CMR. Resting heart rate was 72 ± 14 beats per minute (bpm) and rose to peak of 124 ± 17 bpm (95 ± 50% increase, P < 0.005) with regadenoson. Image quality was considered good or diagnostic in all cases. Three patients had irreversible perfusion defects. Four patients had reversible perfusion defects. Nine of the patients underwent cardiac catheterization with angiography and the findings showed excellent agreement. Regadenoson might be a safe and

  13. Myocardial perfusion in type 2 diabetes with left ventricular hypertrophy: normalisation by acute angiotensin-converting enzyme inhibition

    Energy Technology Data Exchange (ETDEWEB)

    Hesse, Birger; Meyer, Christian; Hove, Jens D.; Holm, Soeren; Kofoed, Klaus F. [Department of Clinical Physiology and Nuclear Medicine, KF 4011, Rigshospitalet, University of Copenhagen, Blegdamsvej 9, 2100, Copenhagen (Denmark); Nielsen, Flemming S.; Sato, Asako; Parving, Hans-Henrik [Steno Diabetes Center, Gentofte (Denmark); Bang, Lia E.; Svendsen, Tage L. [Department of Internal Medicine, Naestved County Hospital (Denmark); Opie, Lionel H. [Department of Medicine, Cape Heart Center, University of Cape Town (South Africa)

    2004-03-01

    The purpose of this study was to assess whether acute angiotensin-converting enzyme (ACE) inhibition would improve myocardial perfusion and perfusion reserve in a subpopulation of normotensive patients with diabetes and left ventricular hypertrophy (LVH), both independent risk factors of coronary disease. Using positron emission tomography (PET), we investigated the response of regional myocardial perfusion to acute ACE inhibition with i.v. infusion of perindoprilat (vs saline infusion as control, minimum interval 3 days) in 12 diabetic patients with LVH. Myocardial perfusion was quantified with PET using nitrogen-13 ammonia infused at rest and during dipyridamole hyperaemia. Twelve healthy control subjects were included in the study, five of whom were also studied with perindoprilat. Mean blood pressure in normo-albuminuric, asymptomatic patients was 123{+-}7/65{+-}9 mmHg. Compared with controls, maximal perfusion was reduced in patients (1.8{+-}0.6 vs 2.5{+-}1.0 ml min{sup -1} g{sup -1}; P<0.05), and perfusion reserve was also lower, at borderline significance (2.7{+-}1.0 vs 3.6{+-}1.3; P=0.059). During perindoprilat infusion, myocardial perfusion reserve in patients increased to 3.9{+-}0.9 (P<0.001) due to normalisation of maximal perfusion (2.3{+-}0.5 ml min{sup -1} g{sup -1}, P<0.01). In the five control subjects both resting and hyperaemic perfusion remained unchanged during perindoprilat infusion. It is concluded that acute ACE inhibition with perindoprilat improves maximal achieved myocardial perfusion in non-hypertensive patients with diabetes and LVH. (orig.)

  14. The Effect of Milk, Water and Lemon Juice on Various Subdiaphragmatic Activity-Related Artifacts in Myocardial Perfusion Imaging

    OpenAIRE

    Malek; Hedayati; Yaghoobi; Bitarafan-Rajabi; Firoozabadi; Rastgou

    2015-01-01

    Background Subdiaphragmatic activity can produce subdiaphragmatic-related artifacts, which can degrade the quality of myocardial perfusion imaging (MPI). Objectives We examined the impact of drinking milk, water, and lemon juice on different subdiaphragmatic-related artifacts by using 99mTc-sestamibi myocardial single-photon emission computed tomography (SPECT) in order to determine a feasible method for improving the image qualit...

  15. Effect of improving spatial or temporal resolution on image quality and quantitative perfusion assessment with k-t SENSE acceleration in first-pass CMR myocardial perfusion imaging.

    Science.gov (United States)

    Maredia, Neil; Radjenovic, Aleksandra; Kozerke, Sebastian; Larghat, Abdulghani; Greenwood, John P; Plein, Sven

    2010-12-01

    k-t Sensitivity-encoded (k-t SENSE) acceleration has been used to improve spatial resolution, temporal resolution, and slice coverage in first-pass cardiac magnetic resonance myocardial perfusion imaging. This study compares the effect of investing the speed-up afforded by k-t SENSE acceleration in spatial or temporal resolution. Ten healthy volunteers underwent adenosine stress myocardial perfusion imaging using four saturation-recovery gradient echo perfusion sequences: a reference sequence accelerated by sensitivity encoding (SENSE), and three k-t SENSE-accelerated sequences with higher spatial resolution ("k-t High"), shorter acquisition window ("k-t Fast"), or a shared increase in both parameters ("k-t Hybrid") relative to the reference. Dark-rim artifacts and image quality were analyzed. Semiquantitative myocardial perfusion reserve index (MPRI) and Fermi-derived quantitative MPR were also calculated. The k-t Hybrid sequence produced highest image quality scores at rest (P = 0.015). Rim artifact thickness and extent were lowest using k-t High and k-t Hybrid sequences (P spatial resolution by k-t SENSE acceleration produces the greatest reduction in dark rim artifact. There is good agreement between k-t SENSE and standard acquisition methods for semiquantitative and fully quantitative myocardial perfusion analysis. Copyright © 2010 Wiley-Liss, Inc.

  16. Single photon emission computed tomography of technetium-99m tetrofosmin myocardial perfusion imaging in patients with systemic lupus erythematosus-A preliminary report

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Jen-Jhy; Hsu, Hsiu-Bao; Sun, Shung-Shung; Kao, Chia-Hung [China Medical Coll., Taichung, Taiwan (China). Hospital; Wang, Jhi-Joung [Chi-Mei Medical Center, Tainan, Taiwan (China); Ho, Shung-Tai [National Defense Medical Center, Taipei, Taiwan (China). School of Medicine

    2003-01-01

    The purpose of this study was to evaluate the utility of single-photon emission computed tomography (SPECT) of technetium-99m tetrofosmin (Tc-99m TF) myocardial perfusion imaging to detect myocardial involvement in patients with systemic lupus erythematosus (SLE). Three groups of subjects-group 1: 25 SLE female patients with non-specific cardiac symptoms and signs, group 2: 25 female SLE patients without any cardiac symptoms and signs, and group 3: 25 female healthy controls-were evaluated by comparing rest and dipyridamole-stress Tc-99m TF myocardial perfusion SPECT. Tc-99m TF myocardial perfusion SPECT revealed perfusion defects in 88% and 40% of the cases in groups 1 and 2, respectively. However, no cases in group 3 demonstrated myocardial perfusion defects. Tc-99m TF myocardial perfusion SPECT is a useful noninvasive imaging modality to detect cardiac involvement in SLE patients with or without cardiac symptoms and signs. (author)

  17. Imaging of brain tumors in AIDS patients by means of dual-isotope thallium-201 and technetium-99m sestamibi single-photon emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    De La Pena, R.C.; Ketonen, L.; Villanueva-Meyer, J. [Dept. of Radiology, Univ. of Texas, Galveston (United States)

    1998-10-01

    Our aim was to evaluate the use of dual-isotope thallium-201 (Tl) and technetium-99m sestamibi (sestamibi) simultaneous acquisition in brain single-photon emission tomography (SPET) for the differentiation between brain lymphoma and benign central nervous system (CNS) lesions in AIDS patients. Thirty-six consecutive patients with enhancing mass lesions on magnetic resonance (MR) imaging were included in the study. SPET of the brain was performed to obtain simultaneous Tl and sestamibi images. Regions-of-interest were drawn around the lesion and on the contralateral side to calculate uptake ratios. The final diagnosis was reached by pathologic findings in 17 patients and clinical and/or MR follow-up in 19 patients. Of the 36 patients, 11 had brain lymphoma, 1 glioblastoma multiforme, 15 toxoplasmosis and 9 other benign CNS lesions. Correlation between SPET and the final diagnosis revealed in 10 true-positive, 23 true-negative, 1 false-positive and 2 false-negative studies. All patients with toxoplasmosis had negative scans. A patient with a purulent infection had positive scans. Tl and sestamibi scans were concordant in every lesion. The same lesions that took up Tl were also visualized with sestamibi. However, sestamibi scans showed higher lesion-to-normal tissue uptake ratios (3.7{+-}1.8) compared with those of Tl (2.3{+-}0.8, P<0.002). Simultaneous acquisition of Tl and sestamibi can help differentiate CNS lymphoma from benign brain lesions in AIDS patients. (orig.) With 2 figs., 2 tabs., 34 refs.

  18. Radiation-induced myocardial perfusion abnormalities in breast cancer patients following external beam radiation therapy

    Directory of Open Access Journals (Sweden)

    Mohammad Eftekhari

    2015-01-01

    Full Text Available Objective(s: Radiation therapy for breast cancer can induce myocardial capillary injury and increase cardiovascular morbidity and mortality. A prospective cohort was conducted to study the prevalence of myocardial perfusion abnormalities following radiation therapy of left-sided breast cancer patients as compared to those with right–sided cancer. Methods: To minimize potential confounding factors, only those patients with low 10-year risk of coronary artery disease (based on Framingham risk scoring were included. All patients were initially treated by modified radical mastectomy and then were managed by postoperative 3D Conformal Radiation Therapy (CRT to the surgical bed with an additional 1-cm margin, delivered by 46-50 Gy (in 2 Gy daily fractions over a 5-week course. The same dose-adjusted chemotherapy regimen (including anthracyclines, cyclophosphamide and taxol was given to all patients. Six months after radiation therapy, all patients underwent cardiac SPECT for the evaluation of myocardial perfusion. Results: A total of 71 patients with a mean age of 45.3±7.2 years [35 patients with leftsided breast cancer (exposed and 36 patients with right-sided cancer (controls] were enrolled. Dose-volume histogram (DVH [showing the percentage of the heart exposed to >50% of radiation] was significantly higher in patients with left-sided breast cancer. Visual interpretation detected perfusion abnormalities in 42.9% of cases and 16.7% of controls (P=0.02, Odds ratio=1.46. In semiquantitative segmental analysis, only apical (28.6% versus 8.3%, P=0.03 and anterolateral (17.1% versus 2.8%, P=0.049 walls showed significantly reduced myocardial perfusion in the exposed group. Summed Stress Score (SSS of>3 was observed in twelve cases (34.3%, while in five of the controls (13.9%,(Odds ratio=1.3. There was no significant difference between the groups regarding left ventricular ejection fraction. Conclusion: The risk of radiation induced myocardial

  19. [Comparison of low-dose dobutamine echocardiography and dual-isotope emission simultaneous myocardial perfusion acquisition for myocardial viability assessment].

    Science.gov (United States)

    Fang, Li-Gang; Chen, Li-Bo; Li, Fang; Zhu, Wen-Ling; Fang, Quan

    2007-04-01

    To compare the value of low-dose dobutamine echocardiography (LDDE) and dual-isotope emission simultaneous myocardial perfusion acquisition (technetium-99-m-tetrofosmin/fluorine 18-fluorodeoxy-glucose) single-photon emission computed tomography (DISA-SPECT) for myocardial viability assessment in patients with acute myocardial infarction (MI). LDDE and DISA-SPECT were performed in 44 patients within 5-10 days after onset of first acute MI and percutaneous coronary intervention was made thereafter. A 16-segment semi-quantitative scoring model was adopted for both techniques. Wall motion improvement at follow-up (3 months after acute MI) compared with baseline before dobutamine infusion derived from two dimensional images was used as golden criteria for myocardial viability. The sensitivity, specificity, diagnostic accuracy, positive and predictive values for identification of viable myocardium were 77%, 82%, 79%, 82% and 77%, respectively by LDDE and 85%, 62%, 74%, 71% and 79%, respectively by DISA. No difference was found between LDDE and DISA for identifying viable myocardium in hypokinetic segments (74.1% vs. 77.6%, P > 0.05) but less viable myocardium was detected by LDDE than DISA in akinetic segments (29% vs. 53%, P DISA compared to LDDE. Combined use of the two techniques could improve viable myocardium detection in patients with acute MI.

  20. Myocardial uptake of cocaine and effects of cocaine on myocardial substrate utilization and perfusion in hypertensive rats

    Energy Technology Data Exchange (ETDEWEB)

    Som, P.; Wang, G.J. (Brookhaven National Lab., Upton, NY (United States)); Oster, Z.H. (State Univ. of New York, Stony Brook, NY (United States)); Knapp, F.F. Jr. (Oak Ridge National Lab., TN (United States)); Yonekura, Y. (Kyoto Univ. (Japan). Faculty of Medicine); Fujibayashi, Y. (Kyoto Univ. (Japan). Hospital); Yamamoto, K. (Fukui Univ. (Japan). Medical School); Kubota, K. (Tohoku Univ., Sendai

    1992-01-01

    Cocaine abuse is a problem causing world-wide concern and the number of deaths following cocaine use is increasing. Cardiovascular complications following cocaine include severe tachyarrythmias, pulmonary edema, myocardial infarction, and acute renal failure, which are major problems confronting emergency facilities. While the studies of cocaine effects on the brain have been given the most attention, it is clear that the effects of cocaine on the cardiovascular system are of great importance, given the increasing number of reports on sudden death and myocardial infarctions in young adults related to cocaine use. The precise mechanisms of cardiotoxic actions of cocaine are unclear. We investigated the whole-body distribution of C-14-labeled cocaine to determine the cocaine-binding sites, including blocking experiments to determine the nature of regional binding sites, and differential response of the normal vs. diseased heart (hypertensive cardiomyopathy) in an animal model to mimic a potentially high risk population. We investigated the acute effects of cocaine on myocardial metabolism using two myocardial energy substrate analogs, fatty acid and glucose with comparison with regional perfusion.

  1. Myocardial uptake of cocaine and effects of cocaine on myocardial substrate utilization and perfusion in hypertensive rats

    Energy Technology Data Exchange (ETDEWEB)

    Som, P.; Wang, G.J. [Brookhaven National Lab., Upton, NY (United States); Oster, Z.H. [State Univ. of New York, Stony Brook, NY (United States); Knapp, F.F. Jr. [Oak Ridge National Lab., TN (United States); Yonekura, Y. [Kyoto Univ. (Japan). Faculty of Medicine; Fujibayashi, Y. [Kyoto Univ. (Japan). Hospital; Yamamoto, K. [Fukui Univ. (Japan). Medical School; Kubota, K. [Tohoku Univ., Sendai (Japan)

    1992-12-31

    Cocaine abuse is a problem causing world-wide concern and the number of deaths following cocaine use is increasing. Cardiovascular complications following cocaine include severe tachyarrythmias, pulmonary edema, myocardial infarction, and acute renal failure, which are major problems confronting emergency facilities. While the studies of cocaine effects on the brain have been given the most attention, it is clear that the effects of cocaine on the cardiovascular system are of great importance, given the increasing number of reports on sudden death and myocardial infarctions in young adults related to cocaine use. The precise mechanisms of cardiotoxic actions of cocaine are unclear. We investigated the whole-body distribution of C-14-labeled cocaine to determine the cocaine-binding sites, including blocking experiments to determine the nature of regional binding sites, and differential response of the normal vs. diseased heart (hypertensive cardiomyopathy) in an animal model to mimic a potentially high risk population. We investigated the acute effects of cocaine on myocardial metabolism using two myocardial energy substrate analogs, fatty acid and glucose with comparison with regional perfusion.

  2. Transmural myocardial perfusion gradients in relation to coronary artery stenoses severity assessed by cardiac multidetector computed tomography

    DEFF Research Database (Denmark)

    Linde, Jesper James; Kühl, Jørgen Tobias; Hove, Jens Dahlgaard

    2015-01-01

    = stress - PI/rest - PI), and the transmural perfusion ratio (TPR = subendocardium/subepicardium) were calculated. A coronary artery stenosis ≥50 % was present in 49 patients (25 %). Rest-PI and rest-TPR values were similar in patients with and without a coronary artery stenosis ≥50 %, whereas stress-PI...... stenosis assessed by MDCT angiography and semi-quantitative myocardial MDCT perfusion in 200 symptomatic patients. The perfusion index (PI = mean myocardial attenuation density/mean left ventricular lumen attenuation density) at rest and during adenosine stress, the myocardial perfusion reserve (MPR......, stress-TPR and MPR were significantly reduced in patients with a stenosis ≥50 % (p PI was significantly higher than subepicardial PI at rest and during stress for patients without a significant stenosis, whereas this difference was blurred...

  3. Myocardial perfusion defects and the left ventricular ejection fraction disclosed by scintigraphy in patients with primary hyperparathyroidism

    DEFF Research Database (Denmark)

    Ogard, Christina Gerlach; Søndergaard, Susanne Bonnichsen; Vestergaard, Henrik

    2005-01-01

    Patients with primary hyperparathyroidism (PHPT) have increased risk of cardiovascular disease. For patients undergoing preoperative parathyroid imaging with 99mTc-sestamibi single photon emission computed tomography (SPECT), we combined cervical SPECT and gated cardiac SPECT to achieve information...... about the localization of parathyroid adenomas, myocardial perfusion, and the left ventricular ejection fraction (LVEF) at rest. A series of 22 patients with PHPT and no history of myocardial infarction or angina pectoris were recruited consecutively. At 60 minutes after injection of 700 MBq 99m......Tc-sestamibi, SPECT of the neck and gated myocardial perfusion SPECT were performed at the same time. All of the patients who underwent parathyroidectomy had the parathyroid adenoma localized as predicted from the SPECT. Five patients (23%) had myocardial perfusion defects extending more than 15% (range 15...

  4. Considerations when measuring myocardial perfusion reserve by cardiovascular magnetic resonance using regadenoson.

    Science.gov (United States)

    Bhave, Nicole M; Freed, Benjamin H; Yodwut, Chattanong; Kolanczyk, Denise; Dill, Karin; Lang, Roberto M; Mor-Avi, Victor; Patel, Amit R

    2012-12-28

    Adenosine cardiovascular magnetic resonance (CMR) can accurately quantify myocardial perfusion reserve. While regadenoson is increasingly employed due to ease of use, imaging protocols have not been standardized. We sought to determine the optimal regadenoson CMR protocol for quantifying myocardial perfusion reserve index (MPRi) - more specifically, whether regadenoson stress imaging should be performed before or after rest imaging. Twenty healthy subjects underwent CMR perfusion imaging during resting conditions, during regadenoson-induced hyperemia (0.4 mg), and after 15 min of recovery. In 10/20 subjects, recovery was facilitated with aminophylline (125 mg). Myocardial time-intensity curves were used to obtain left ventricular cavity-normalized myocardial up-slopes. MPRi was calculated in two different ways: as the up-slope ratio of stress to rest (MPRi-rest), and the up-slope ratio of stress to recovery (MPRi-recov). In all 20 subjects, MPRi-rest was 1.78 ± 0.60. Recovery up-slope did not return to resting levels, regardless of aminophylline use. Among patients not receiving aminophylline, MPRi-recov was 36 ± 16% lower than MPRi-rest (1.13 ± 0.38 vs. 1.82 ± 0.73, P = 0.001). In the 10 patients whose recovery was facilitated with aminophylline, MPRi-recov was 20 ± 24% lower than MPRi-rest (1.40 ± 0.35 vs. 1.73 ± 0.43, P = 0.04), indicating incomplete reversal. In 3 subjects not receiving aminophylline and 4 subjects receiving aminophylline, up-slope at recovery was greater than at stress, suggesting delayed maximal hyperemia. MPRi measurements from regadenoson CMR are underestimated if recovery perfusion is used as a substitute for resting perfusion, even when recovery is facilitated with aminophylline. True resting images should be used to allow accurate MPRi quantification. The delayed maximal hyperemia observed in some subjects deserves further study. ClinicalTrials.gov NCT00871260.

  5. Considerations when measuring myocardial perfusion reserve by cardiovascular magnetic resonance using regadenoson

    Directory of Open Access Journals (Sweden)

    Bhave Nicole M

    2012-12-01

    Full Text Available Abstract Background Adenosine cardiovascular magnetic resonance (CMR can accurately quantify myocardial perfusion reserve. While regadenoson is increasingly employed due to ease of use, imaging protocols have not been standardized. We sought to determine the optimal regadenoson CMR protocol for quantifying myocardial perfusion reserve index (MPRi – more specifically, whether regadenoson stress imaging should be performed before or after rest imaging. Methods Twenty healthy subjects underwent CMR perfusion imaging during resting conditions, during regadenoson-induced hyperemia (0.4 mg, and after 15 min of recovery. In 10/20 subjects, recovery was facilitated with aminophylline (125 mg. Myocardial time-intensity curves were used to obtain left ventricular cavity-normalized myocardial up-slopes. MPRi was calculated in two different ways: as the up-slope ratio of stress to rest (MPRi-rest, and the up-slope ratio of stress to recovery (MPRi-recov. Results In all 20 subjects, MPRi-rest was 1.78 ± 0.60. Recovery up-slope did not return to resting levels, regardless of aminophylline use. Among patients not receiving aminophylline, MPRi-recov was 36 ± 16% lower than MPRi-rest (1.13 ± 0.38 vs. 1.82 ± 0.73, P = 0.001. In the 10 patients whose recovery was facilitated with aminophylline, MPRi-recov was 20 ± 24% lower than MPRi-rest (1.40 ± 0.35 vs. 1.73 ± 0.43, P = 0.04, indicating incomplete reversal. In 3 subjects not receiving aminophylline and 4 subjects receiving aminophylline, up-slope at recovery was greater than at stress, suggesting delayed maximal hyperemia. Conclusions MPRi measurements from regadenoson CMR are underestimated if recovery perfusion is used as a substitute for resting perfusion, even when recovery is facilitated with aminophylline. True resting images should be used to allow accurate MPRi quantification. The delayed maximal hyperemia observed in some subjects deserves further study. Trial

  6. The effect of beta blocker withdrawal on adenosine myocardial perfusion imaging.

    Science.gov (United States)

    Hoffmeister, C; Preuss, R; Weise, R; Burchert, W; Lindner, O

    2014-12-01

    The effect of beta blockers on myocardial blood flow (MBF) under vasodilators has been studied in several SPECT and PET myocardial perfusion imaging (MPI) studies with divergent results. The present study evaluated the effect of a beta blocker withdrawal on quantitative adenosine MBF and on MPI results. Twenty patients with beta blockers and CAD history were studied with quantitative adenosine N-13 ammonia PET. The first study was performed under complete medication and the second after beta blocker withdrawal. The PET studies were independently read with respect to MPI result and clinical decision making. Global MBF showed an increase from 180.2 ± 59.9 to 193.6 ± 60.8 mL·minute(-1)/100 g (P = .02) after beta blocker withdrawal. The segmental perfusion values were closely correlated (R(2) = 0.82) over the entire range of perfusion values. An essentially different interpretation after beta blocker discontinuation was found in two cases (10%). A beta blocker withdrawal induces an increase in adenosine MBF. In the majority of cases, MPI interpretation and decision making are independent of beta blocker intake. If a temporary beta blocker withdrawal before MPI is not possible or was not realized by the patient, it is appropriate to perform adenosine stress testing without loss of the essential MPI result.

  7. Dipyridamole stress myocardial perfusion by computed tomography in patients with left bundle branch block

    Science.gov (United States)

    Cabeda, Estêvan Vieira; Falcão, Andréa Maria Gomes; Soares Jr., José; Rochitte, Carlos Eduardo; Nomura, César Higa; Ávila, Luiz Francisco Rodrigues; Parga, José Rodrigues

    2015-01-01

    Background Functional tests have limited accuracy for identifying myocardial ischemia in patients with left bundle branch block (LBBB). Objective To assess the diagnostic accuracy of dipyridamole-stress myocardial computed tomography perfusion (CTP) by 320-detector CT in patients with LBBB using invasive quantitative coronary angiography (QCA) (stenosis ≥ 70%) as reference; to investigate the advantage of adding CTP to coronary computed tomography angiography (CTA) and compare the results with those of single photon emission computed tomography (SPECT) myocardial perfusion scintigraphy. Methods Thirty patients with LBBB who had undergone SPECT for the investigation of coronary artery disease were referred for stress tomography. Independent examiners performed per-patient and per-coronary territory assessments. All patients gave written informed consent to participate in the study that was approved by the institution’s ethics committee. Results The patients’ mean age was 62 ± 10 years. The mean dose of radiation for the tomography protocol was 9.3 ± 4.6 mSv. With regard to CTP, the per-patient values for sensitivity, specificity, positive and negative predictive values, and accuracy were 86%, 81%, 80%, 87%, and 83%, respectively (p = 0.001). The per-territory values were 63%, 86%, 65%, 84%, and 79%, respectively (p < 0.001). In both analyses, the addition of CTP to CTA achieved higher diagnostic accuracy for detecting myocardial ischemia than SPECT (p < 0.001). Conclusion The use of the stress tomography protocol is feasible and has good diagnostic accuracy for assessing myocardial ischemia in patients with LBBB. PMID:26421532

  8. Dipyridamole stress myocardial perfusion by computed tomography in patients with left bundle branch block

    Directory of Open Access Journals (Sweden)

    Estêvan Vieira Cabeda

    2015-01-01

    Full Text Available AbstractBackground:Functional tests have limited accuracy for identifying myocardial ischemia in patients with left bundle branch block (LBBB.Objective:To assess the diagnostic accuracy of dipyridamole-stress myocardial computed tomography perfusion (CTP by 320-detector CT in patients with LBBB using invasive quantitative coronary angiography (QCA (stenosis ≥ 70% as reference; to investigate the advantage of adding CTP to coronary computed tomography angiography (CTA and compare the results with those of single photon emission computed tomography (SPECT myocardial perfusion scintigraphy.Methods:Thirty patients with LBBB who had undergone SPECT for the investigation of coronary artery disease were referred for stress tomography. Independent examiners performed per-patient and per-coronary territory assessments. All patients gave written informed consent to participate in the study that was approved by the institution’s ethics committee.Results:The patients’ mean age was 62 ± 10 years. The mean dose of radiation for the tomography protocol was 9.3 ± 4.6 mSv. With regard to CTP, the per-patient values for sensitivity, specificity, positive and negative predictive values, and accuracy were 86%, 81%, 80%, 87%, and 83%, respectively (p = 0.001. The per-territory values were 63%, 86%, 65%, 84%, and 79%, respectively (p < 0.001. In both analyses, the addition of CTP to CTA achieved higher diagnostic accuracy for detecting myocardial ischemia than SPECT (p < 0.001.Conclusion:The use of the stress tomography protocol is feasible and has good diagnostic accuracy for assessing myocardial ischemia in patients with LBBB.

  9. Quantitative perfusion parameters in a cohort of patients with no known ischemic heart disease and normal myocardial perfusion imaging studied by 82Rb-PET

    DEFF Research Database (Denmark)

    Hoff, Camilla; Balche, Abdallah; Majgaard, J

    commercially available software (QPET, Cedars Sinai). Parameters included were regional and global rest and stress myocardial blood flow (MBF) values, ejection fraction (EF) and total perfusion deficit (TPD). Results Mean global MBF at stress was 2.92 mL/g/min (±SD 0.49), lower limit (LL) 1.94 m...

  10. Tc{sup 99m}-sestamibi dosimetry in myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Toledo, Janine M.; Trindade, Bruno M.; Campos, Tarcisio P.R., E-mail: janine.toledo@gmail.com [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear. Programa de Pos-Graduaco em Ciencias e Tecnicas Nucleares

    2015-07-01

    This paper addressed myocardial perfusion imaging providing a spatial dosimetric investigation of the {sup 99m}Tc-radiopharmaceutical dose distribution at the myocardium. Radiological data manipulation was performed in order to create a computational voxel model of the heart. A set of images obtained by thoracic angiotomography and abdominal aorta was set up providing anatomic and functional information for heart modeling in SISCODES code. A homogeneous distribution of {sup 99m}Tc was assumed into the cardiac muscle. Simulations of the transport of particles through the voxel and the interaction with the heart tissues were performed on the MCNP - Monte Carlo Code. The spatial dose distribution in the heart model is displayed as well as the dose versus volume histogram of the heart muscle. The present computational tools can generate spatial doses distribution in myocardial perfusion imaging. Specially, the dosimetry performed elucidates imparted dose distribution in the myocardial muscle per unit of injected {sup 99m} Tc activity, which can contribute to future deterministic effect investigations. (author)

  11. Effects of potassium channel opener on the kinetics of thallium-201 in in-vitro and in-vivo

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J.; Kim, E. J.; Ahn, B. C.; Chae, S. C.; Lee, K. B. [College of Medicine, Kyungpook National Univ., Taegu (Korea, Republic of); Kim, C. K. [Mt. Sinai Medical School, New York (United States)

    1997-07-01

    Potassium channel opener (K-opener) opens membrane ATP-sensitive K{sup +}-channel and induces and increase in potassium efflux from cells. K-openers are powerful smooth muscle relaxants and currently used as antihypertensive, antianginal drugs or bronchodilators in clinic. Pharmacologic potency of newly synthesized K-opener is being evaluated with efflux capacity of preincubated Rb-83 from the isolated aortic vascular tissue preparation. Thallium has similar characteristics to those of rubidium and potassium in vivo. To evaluate the effect of pinacidil (a potent K-opener) on Tl-201 biokinetics, we have performed uptake/washout studies in cultured myocytes, and mice biodistribution study. Primary culture of spontaneous contracting myocytes was undertake from hearts of newborn Sprague-Dawley rat. Different concentration of pinacidil (100nM or 10uM) was co-incubated with Tl-201 in HBSS buffer to evaluate its effect on cellular uptake, or challenged to myocyte preparations pre-incubated with Tl-201 for washout study. Pinacidil was injected into mice simultaneous or 10-min after Tl-201 injection, and organ uptake and whole body retention ratio was measured using gamma counter or dose calibrator. Co-incubation of pinacidil with Tl-201 resulted in a decrease in Tl uptake into myocytes by 1.6 - 2.5 times, and an increase in washout by 1.6 - 3.1 times. Pinacidil injection resulted in mild decrease in blood, heart and liver uptake in mice, bur renal uptake was markedly decreased in a dose dependent manner. These results suggest that the pinacidil Tl-201 kinetics and may potentially affect the interpretation of Tl-201 myocardial imaging.

  12. Low dose dynamic CT myocardial perfusion imaging using a statistical iterative reconstruction method

    Energy Technology Data Exchange (ETDEWEB)

    Tao, Yinghua [Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53705 (United States); Chen, Guang-Hong [Department of Medical Physics and Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin 53705 (United States); Hacker, Timothy A.; Raval, Amish N. [Department of Medicine, University of Wisconsin-Madison, Madison, Wisconsin 53792 (United States); Van Lysel, Michael S.; Speidel, Michael A., E-mail: speidel@wisc.edu [Department of Medical Physics and Department of Medicine, University of Wisconsin-Madison, Madison, Wisconsin 53705 (United States)

    2014-07-15

    Purpose: Dynamic CT myocardial perfusion imaging has the potential to provide both functional and anatomical information regarding coronary artery stenosis. However, radiation dose can be potentially high due to repeated scanning of the same region. The purpose of this study is to investigate the use of statistical iterative reconstruction to improve parametric maps of myocardial perfusion derived from a low tube current dynamic CT acquisition. Methods: Four pigs underwent high (500 mA) and low (25 mA) dose dynamic CT myocardial perfusion scans with and without coronary occlusion. To delineate the affected myocardial territory, an N-13 ammonia PET perfusion scan was performed for each animal in each occlusion state. Filtered backprojection (FBP) reconstruction was first applied to all CT data sets. Then, a statistical iterative reconstruction (SIR) method was applied to data sets acquired at low dose. Image voxel noise was matched between the low dose SIR and high dose FBP reconstructions. CT perfusion maps were compared among the low dose FBP, low dose SIR and high dose FBP reconstructions. Numerical simulations of a dynamic CT scan at high and low dose (20:1 ratio) were performed to quantitatively evaluate SIR and FBP performance in terms of flow map accuracy, precision, dose efficiency, and spatial resolution. Results: Forin vivo studies, the 500 mA FBP maps gave −88.4%, −96.0%, −76.7%, and −65.8% flow change in the occluded anterior region compared to the open-coronary scans (four animals). The percent changes in the 25 mA SIR maps were in good agreement, measuring −94.7%, −81.6%, −84.0%, and −72.2%. The 25 mA FBP maps gave unreliable flow measurements due to streaks caused by photon starvation (percent changes of +137.4%, +71.0%, −11.8%, and −3.5%). Agreement between 25 mA SIR and 500 mA FBP global flow was −9.7%, 8.8%, −3.1%, and 26.4%. The average variability of flow measurements in a nonoccluded region was 16.3%, 24.1%, and 937

  13. Low-dose 4D myocardial perfusion with x-ray micro-CT

    Science.gov (United States)

    Clark, D. P.; Badea, C. T.

    2017-03-01

    X-ray CT is widely used, both clinically and pre-clinically, for fast, high-resolution, anatomic imaging; however, compelling opportunities exist to expand its use in functional imaging applications. For instance, temporally-resolved CT data can detail cardiac motion and blood flow dynamics for one-stop cardiovascular CT imaging procedures. In previous work, we demonstrated efficient, low-dose projection acquisition and reconstruction strategies for cardiac micro-CT imaging and for multiple-injection micro-CT perfusion imaging. Here, we extend this previous work with regularization based on rank-sparse kernel regression and on filtration with the Karhunen-Loeve transform. Using a dual source, prospectively gated sampling strategy which produces an approximately uniform distribution of projections, we apply this revised algorithm to the assessment of both myocardial perfusion and cardiac functional metrics from the same set of projection data. We test the algorithm in simulations using a modified version of the MOBY mouse phantom which contains realistic perfusion and cardiac dynamics. The proposed algorithm reduces the reconstruction error by 81% relative to unregularized, algebraic reconstruction. The results confirm our ability to simultaneously solve for cardiac temporal motion and perfusion dynamics. In future work, we will apply the algorithm and sampling protocol to small animal cardiac studies.

  14. Regadenoson: review of its established role in myocardial perfusion imaging and emerging applications.

    Science.gov (United States)

    Palani, Gurunanthan; Ananthasubramaniam, Karthikeyan

    2013-01-01

    Myocardial perfusion imaging is a well-established noninvasive modality for the diagnosis and prognosis of coronary artery disease. The pharmacologic stress agents adenosine and dipyridamole are widely used in imaging studies, but cause undesirable side effects, like atrioventricular block and bronchospasm, due to their nonselective adenosine receptor activation. Furthermore, the mode of administration of these agents as a bolus infusion is less preferred. Regadenoson, an A2A adenosine receptor selective pharmacologic stress agent was approved in 2008 and is widely used instead of adenosine and dipyridamole. This article reviews regadenosons structure, mechanism of action, advantages over adenosine and dipyridamole, and its role in various patient populations undergoing stress perfusion imaging. Emerging applications where regadenoson could be of potential use are also explored.

  15. Estimation of myocardial perfusion and viability using simultaneous 99mTc-tetrofosmin--FDG collimated SPECT.

    Science.gov (United States)

    Fukuchi, K; Katafuchi, T; Fukushima, K; Shimotsu, Y; Toba, M; Hayashida, K; Takamiya, M; Ishida, Y

    2000-08-01

    This study was designed to elucidate the usefulness of crosstalk correction for dual-isotope simultaneous acquisition (DISA) with 99mTc-tetrofosmin and FDG in estimating myocardial perfusion and viability. Eighteen patients with coronary artery disease were studied. First, SPECT was performed with a low-energy high-resolution collimator after a single injection of 99mTc-tetrofosmin (single 99mTc-tetrofosmin). Second, PET and DISA with an ultra-high-energy collimator were performed after glucose loading and an injection of FDG. DISA was designed to operate with simultaneous 3-channel acquisition, and weighted scatter correction of crosstalk from the 18F photopeak to the 99mTc photopeak was performed by modification of an existing dual-window technique. The FDG SPECT images were compared with the images obtained by PET. Both crosstalk-corrected and uncorrected 99mTc-tetrofosmin images were generated and compared with the single 99mTc-tetrofosmin images. Regional percentage uptake of FDG agreed well between DISA and PET. However, regional percentage uptake of 99mTc-tetrofosmin was generally higher on the uncorrected 99mTc-tetrofosmin images than on the single 99mTc-tetrofosmin images, especially in areas of low flow (percentage count of 99mTc-tetrofosmin > or = 50%). The crosstalk correction contributed to improving the agreement between regional percentage uptakes and significantly improved the detectability of myocardial perfusion-metabolism mismatching. With 3-channel acquisition and weighted-scatter correction of crosstalk from the 18F photopeak to the 99mTc photopeak, DISA with 99mTc-tetrofosmin and FDG is feasible for assessing regional myocardial perfusion and viability.

  16. Radiation dose to radiosensitive organs in PET/CT myocardial perfusion examination using versatile optical fibre

    Science.gov (United States)

    Salasiah, M.; Nordin, A. J.; Fathinul Fikri, A. S.; Hishar, H.; Tamchek, N.; Taiman, K.; Ahmad Bazli, A. K.; Abdul-Rashid, H. A.; Mahdiraji, G. A.; Mizanur, R.; Noor, Noramaliza M.

    2013-05-01

    Cardiac positron emission tomography (PET) provides a precise method in order to diagnose obstructive coronary artery disease (CAD), compared to single photon emission tomography (SPECT). PET is suitable for obese and patients who underwent pharmacologic stress procedures. It has the ability to evaluate multivessel coronary artery disease by recording changes in left ventricular function from rest to peak stress and quantifying myocardial perfusion (in mL/min/g of tissue). However, the radiation dose to the radiosensitive organs has become crucial issues in the Positron Emission Tomography/Computed Tomography(PET/CT) scanning procedure. The objective of this study was to estimate radiation dose to radiosensitive organs of patients who underwent PET/CT myocardial perfusion examination at Centre for Diagnostic Nuclear Imaging, Universiti Putra Malaysia in one month period using versatile optical fibres (Ge-B-doped Flat Fibre) and LiF (TLD-100 chips). All stress and rest paired myocardial perfusion PET/CT scans will be performed with the use of Rubidium-82 (82Rb). The optic fibres were loaded into plastic capsules and attached to patient's eyes, thyroid and breasts prior to the infusion of 82Rb, to accommodate the ten cases for the rest and stress PET scans. The results were compared with established thermoluminescence material, TLD-100 chips. The result shows that radiation dose given by TLD-100 and Germanium-Boron-doped Flat Fiber (Ge-B-doped Flat Fiber) for these five organs were comparable to each other where the p>0.05. For CT scans,thyroid received the highest dose compared to other organs. Meanwhile, for PET scans, breasts received the highest dose.

  17. Variability of myocardial perfusion dark rim Gibbs artifacts due to sub-pixel shifts

    Directory of Open Access Journals (Sweden)

    Kellman Peter

    2009-05-01

    Full Text Available Abstract Background Gibbs ringing has been shown as a possible source of dark rim artifacts in myocardial perfusion studies. This type of artifact is usually described as transient, lasting a few heart beats, and localised in random segments of the myocardial wall. Dark rim artifacts are known to be unpredictably variable. This article aims to illustrate that a sub-pixel shift, i.e. a small displacement of the pixels with respect to the endocardial border, can result in different Gibbs ringing and hence different artifacts. Therefore a hypothesis for one cause of dark rim artifact variability is given based on the sub-pixel position of the endocardial border. This article also demonstrates the consequences for Gibbs artifacts when two different methods of image interpolation are applied (post-FFT interpolation, and pre-FFT zero-filling. Results Sub-pixel shifting of in vivo perfusion studies was shown to change the appearance of Gibbs artifacts. This effect was visible in the original uninterpolated images, and in the post-FFT interpolated images. The same shifted data interpolated by pre-FFT zero-filling exhibited much less variability in the Gibbs artifact. The in vivo findings were confirmed by phantom imaging and numerical simulations. Conclusion Unless pre-FFT zero-filling interpolation is performed, Gibbs artifacts are very dependent on the position of the subendocardial wall within the pixel. By introducing sub-pixel shifts relative to the endocardial border, some of the variability of the dark rim artifacts in different myocardial segments, in different patients and from frame to frame during first-pass perfusion due to cardiac and respiratory motion can be explained. Image interpolation by zero-filling can be used to minimize this dependency.

  18. Prevalence of myocardial ischaemia as assessed with myocardial perfusion scintigraphy in patients with diabetes mellitus type 2 and mild anginal symptoms

    Energy Technology Data Exchange (ETDEWEB)

    Wiersma, Jacobijne J.; Trip, Mieke D.; Piek, Jan J.; Tijssen, Jan G.P. [Academic Medical Center, Department of Cardiology, Amsterdam (Netherlands); Verberne, Hein J.; Eck-Smit, Berthe L.F. van [Academic Medical Center Amsterdam, Department of Nuclear Medicine, Amsterdam (Netherlands); Holt, Wik L. ten [Amstelland Hospital, Department of Cardiology, Amstelveen (Netherlands)

    2006-12-15

    To determine the prevalence and predictors of reversible myocardial perfusion defects, indicative of myocardial ischaemia, in patients with mild, stable anginal complaints [Canadian Cardiovascular Society classification (CCS) I-II/IV] and diabetes mellitus type 2 (T2DM). A total of 329 patients with T2DM and stable, mild anginal symptoms (CCS I-II/IV) underwent myocardial perfusion scintigraphy. Perfusion images were assessed using a five-point (semi)-quantitative scoring system according to a 17-segment myocardial model. One-hundred and fifty-six (47%) patients showed reversible myocardial perfusion defects defined as a summed difference score of {>=}3. Male gender [odds ratio (OR) 2.28, 95% CI 1.4-3.71, p=0.001], previous myocardial infarction (MI) without revascularisation (OR 3.04, 95% CI 1.28-7.24, p=0.01), and the use of two or more classes of anti-anginal medication (OR 2.36, 95% CI 1.48-3.76, p<0.001) were independent predictors for the presence of reversible defects. By contrast, lipid-lowering therapy reduced the possibility of reversible perfusion defects (OR 0.56, 95% CI 0.33-0.95, p=0.03). Approximately half of the patients with mild, stable angina pectoris and T2DM showed evidence of myocardial ischaemia. Male gender, previous MI and the use of anti-anginal medication were positive predictors and lipid-lowering therapy was a negative predictor for the results of the scintigraphic stress test. (orig.)

  19. Regadenoson in Myocardial Perfusion Study - First Institutional Experiences in Bosnia and Herzegovina.

    Science.gov (United States)

    Beslic, Nermina; Milardovic, Renata; Sadija, Amera; Ceric, Sejla; Raic, Zeljka

    2016-12-01

    Myocardial perfusion imaging (MPI) is widely used in the evaluation of known and suspected coronary artery disease (CAD). Imaging of heart in stress and rest enables the comparison of myocardial uptake of radiotracer in proportion to the needs and coronary flow, which is used for detection of perfusion defects. Exercise stress and pharmacologic agents are used for the stressing purpose. Novel pharmacologic stressor regadenoson is A2A selective adenosine agonist, which selectively binds to the adenosine receptors in coronary arteries causing coronary dilatation. We analyzed 50 myocardial perfusion studies performed with regadenoson as a pharmacologic agent that was injected before Tc99m-sestamibi in stress imaging. Stress and rest sets of images were evaluated for relative uptake of Tc99m-sestamibi in order to detect and characterize perfusion defects. After the injection of regadenoson, hemodynamic parameters and potential side-effects were closely monitored. Side-effects were stratified per severity as mild, moderate and severe. Studies were read by nuclear medicine physicians using quantitative perfusion SPECT software. Additional diagnostic information such as wall motion and wall thickening were provided by gating. Thirty-three patients (66%) experienced one or more side-effects upon the administration of regadenoson, most commonly warmth and chest discomfort. In all patients but one (98%), the symptoms were mild, of short duration and self-limiting. Out of all side-effects registered, 44 (96%) were mild, and 2 (4%) were moderate. Two moderate side-effects developed in one patient with a prior history of asthma, and included shortness of breath and cough. Heart rate changed by 16 +- 31 bpm. Highest increase in blood pressure was 30 mm Hg for systolic, and 10 mm Hg for diastolic. One case of significant decrease in blood pressure was noted from the hypertensive basal values, 50 mm for systolic, and 30 mm Hg for diastolic. ST segment depression of up to 1 mm

  20. Myocardial perfusion imaging in Denmark: activity from 1997 to 2001 and current practice

    DEFF Research Database (Denmark)

    Petersen, Claus Leth; Kjaer, Andreas

    2003-01-01

    A questionnaire was sent to all departments of nuclear medicine in Denmark (n=20) asking for details of myocardial perfusion imaging (MPI), including the number of patients examined each year from 1997 to 2001 and the current clinical and technical practice. All (100%) departments replied...... studies was dipyridamole/adenosine in 76%, exercise in 18% and dobutamine in 6%. Despite these encouraging figures, MPI activity for 2001 remained well below what is recommended by other national and international societies. The anticipated further increase in nuclear cardiology is encouraging...

  1. A generator-produced gallium-68 radiopharmaceutical for PET imaging of myocardial perfusion.

    Directory of Open Access Journals (Sweden)

    Vijay Sharma

    Full Text Available Lipophilic cationic technetium-99m-complexes are widely used for myocardial perfusion imaging (MPI. However, inherent uncertainties in the supply chain of molybdenum-99, the parent isotope required for manufacturing 99Mo/99mTc generators, intensifies the need for discovery of novel MPI agents incorporating alternative radionuclides. Recently, germanium/gallium (Ge/Ga generators capable of producing high quality 68Ga, an isotope with excellent emission characteristics for clinical PET imaging, have emerged. Herein, we report a novel 68Ga-complex identified through mechanism-based cell screening that holds promise as a generator-produced radiopharmaceutical for PET MPI.

  2. Prevalence and predictors of an abnormal stress myocardial perfusion study in asymptomatic patients with type 2 diabetes mellitus

    Energy Technology Data Exchange (ETDEWEB)

    Scholte, Arthur J.H.A.; Schuijf, Joanne D.; Wall, Ernst E. van der; Bax, Jeroen J. [Leiden University Medical Center, Department of Cardiology, Albinusdreef 2, PO Box 9600, Leiden (Netherlands); Kharagjitsingh, Antje V. [Medisch Centrum Haaglanden, Department of Internal Medicine, The Hague (Netherlands); Dibbets-Schneider, Petra; Stokkel, Marcel P. [Leiden University Medical Center, Department of Nuclear Medicine, Leiden (Netherlands)

    2009-04-15

    The purpose of this study was to evaluate the prevalence of an abnormal stress myocardial perfusion study in a cohort of truly asymptomatic patients with type 2 diabetes mellitus using myocardial perfusion imaging by means of single photon emission computed tomography (SPECT). Secondly, we determined which clinical characteristics may predict an abnormal stress myocardial perfusion study in this population. A total of 120 asymptomatic patients (mean age 53{+-}10 years) with type 2 diabetes mellitus and one or more risk factors for coronary artery disease were prospectively recruited from an outpatient diabetes clinic. All patients underwent myocardial perfusion imaging by means of adenosine {sup 99m}Tc sestamibi SPECT. Images were evaluated for the presence of perfusion abnormalities as well as other nonperfusion abnormalities that may indicate extensive ischaemia, including left ventricular dysfunction (defined as a left ventricular ejection fraction <45%), transient ischaemic dilatation and adenosine-induced ST segment depression. Multivariable analysis was performed using a backward selection strategy to identify potential predictors for an abnormal stress myocardial perfusion study. Finally, all patients were followed up for 12 months to determine the occurrence of cardiovascular events: (1) cardiac death, (2) nonfatal myocardial infarction, (3) unstable angina requiring hospitalization, (4) revascularization, or (5) stroke. Of the 120 patients, 40 (33%) had an abnormal stress study, including myocardial perfusion abnormalities in 30 patients (25%). In 10 patients (8%), indicators of extensive (possibly balanced ischaemia) were observed in the absence of abnormal perfusion. The multivariable analysis identified current smoking, duration of diabetes and the cholesterol/high-density lipoprotein (HDL) ratio as independent predictors of an abnormal stress study. During a follow-up period of 12 months six patients (5%) had a cardiovascular event. The current study

  3. Technetium-99m tetrofosmin: Use for myocardial perfusion imaging in the detection of coronary artery disease

    Directory of Open Access Journals (Sweden)

    Helen Erica D’Arceuil

    2010-08-01

    Full Text Available Helen Erica D’ArceuilDepartment of Radiology, Stanford University School of Medicine, California, USAAbstract: Technetium-99m tetrofosmin is a radioactive tracer which is designed for ­myocardial perfusion imaging. Differential tracer uptake allows discrimination between normal and ischemic myocardium. Technetium-99m tetrofosmin has shown excellent utility as a safe, cost-effective, and technically sound agent for use in the diagnosis of coronary artery disease. This paper provides an overview of the available literature on clinical applications of technetium-99m tetrofosmin, and shows how this tracer has gained widespread acceptance as a diagnostic aid since its inception approximately 17 years ago. The various cardiac imaging modalities and imaging protocols which have employed this agent are also briefly reviewed.Keywords: technetium-99m tetrofosmin, myocardial, viability, imaging

  4. Diagnostic and prognostic significance of ischemic electrocardiographic changes with regadenoson-stress myocardial perfusion imaging.

    Science.gov (United States)

    Doukky, Rami; Olusanya, Adebayo; Vashistha, Raj; Saini, Abhimanyu; Fughhi, Ibtihaj; Mansour, Khaled; Nigatu, Abiy; Confer, Kara; Sims, Shannon A

    2015-08-01

    The diagnostic and prognostic value of regadenoson-induced ST-segment depression (ST↓) is not defined. Due to the low incidence of ST↓ ≥1.0 mm with vasodilator stress, a lower threshold to define ischemic ECG response may provide improved clinical utility. We conducted a retrospective cohort study of patients who underwent regadenoson-stress SPECT myocardial perfusion imaging (MPI) followed by coronary angiography within 6 months. Ischemic ST↓ was defined as ≥0.5 mm. The prevalence of angiographically severe coronary artery disease (CAD) and the rates of major adverse cardiac events (MACE) including cardiac death, myocardial infarction, and coronary revascularization were determined. In a diagnostic cohort of 629 subjects, 117 (18.6%) had ST↓ ≥0.5 mm. Severe CAD was more prevalent in the ST↓ ≥0.5 vs ST regadenoson-induced ST↓ ≥0.5 mm was associated with higher rates of severe CAD and MACE, irrespective of MPI finding.

  5. Relative value of thallium-201 and iodine-131 scans in the detection of recurrence or distant metastasis of well differentiated thyroid carcinoma.

    Science.gov (United States)

    Lin, J D; Kao, P F; Weng, H F; Lu, W T; Huang, M J

    1998-07-01

    Radioactive iodine (131I) has been found to be more sensitive and more specific than thallium-201 for the detection of distant metastases and thyroid remnants in the neck in cases of well-differentiated thyroid carcinoma. 201Tl has been deemed particularly useful in localizing metastases or recurrence in patients with a negative 131I scan and abnormal levels of serum thyroglobulin (Tg). This study aimed to: (1) determine the value of 201Tl imaging in localizing metastases or recurrence in patients with well-differentiated thyroid carcinoma, and (2) evaluate the false-positive and false-negative results of 131I and 201Tl scintigraphy. Sixty-two thyroid remnant ablated patients who underwent simultaneous postoperative 201Tl and 131I scans and and serum Tg determinations were evaluated. Fifty patients had papillary thyroid carcinomas and 12 had follicular thyroid carcinomas. 201Tl imaging was performed before the 131I studies. Of the 62 patients who underwent 201Tl imaging studies, 24 were found to have positive results, with local recurrence or distant metastases. Patients with positive results in the 201Tl imaging studies tended to be older, were mor often male, had higher Tg levels and had a higher recurrence rate. Of these 24 patients, ten had negative diagnostic or therapeutic 131I scans. Concurrently, serum Tg levels were less than 5 ng/ml in five of these ten patients. Three patients were deemed false positive by 201Tl scans; one had a parotid tumour, one a periodontal abscess and one lung metastasis. Among the 38 patients with negative 201Tl scans, 11 had positive findings on 131I scans. Three had distant metastases: two with lung metastases and one with bone metastases. Patients with false-positive results on 131I scans included those with biliary tract stones, ovarian cysts, and breast secretion. Of the 27 patients with negative 201Tl and 131I scans, 15 had elevated serum Tg levels. Among these, local recurrence followed by lung metastases was manifested in

  6. Relative value of thallium-201 and iodine-131 scans in the detection of recurrence or distant metastasis of well differentiated thyroid carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Lin Jen-Der; Weng Hsiao-Fen; Lu Wen-Tsoung [Division of Endocrinology and Metabolism, Chang Gung Memorial Hospital (Taiwan, Province of China); Kao Pan-Fu; Huang Miau-Ju [Department of Nuclear Medicine, Chang Gung Memorial Hospital, Taiwan (Taiwan, Province of China)

    1998-07-01

    Radioactive iodine ({sup 131}I) has been found to be more sensitive and more specific than thallium-201 for the detection of distant metastases and thyroid remnants in the neck in cases of well-differentiated thyroid carcinoma. {sup 201}Tl has been deemed particularly useful in localizing metastases or recurrence in patients with a negative {sup 131}I scan and abnormal levels of serum thyroglobulin (Tg). This study aimed to: (1) determine the value of {sup 201}Tl imaging in localizing metastases or recurrence in patients with well-differentiated thyroid carcinoma, and (2) evaluate the false-positive and false-negative results of {sup 131}I and {sup 201}Tl scintigraphy. Sixty-two thyroid remnant ablated patients who underwent simultaneous postoperative {sup 201}Tl and {sup 131}I scans and and serum Tg determinations were evaluated. Fifty patients had papillary thyroid carcinomas and 12 had follicular thyroid carcinomas. {sup 201}Tl imaging was performed before the {sup 131}I studies. Of the 62 patients who underwent {sup 201}Tl imaging studies, 24 were found to have positive results, with local recurrence or distant metastases. Patients with positive results in the {sup 201}Tl imaging studies tended to be older, were mor often male, had higher Tg levels and had a higher recurrence rate. Of these 24 patients, ten had negative diagnostic or therapeutic {sup 131}I scans. Concurrently, serum Tg levels were less than 5 ng/ml in five of these ten patients. Three patients were deemed false positive by {sup 201}Tl scans; one had a parotid tumour, one a periodontal abscess and one lung metastasis. Among the 38 patients with negative {sup 201}Tl scans, 11 had positive findings on {sup 131}I scans. Three had distant metastases: two with lung metastases and one with bone metastases. Patients with false-positive results on {sup 131}I scans included those with biliary tract stones, ovarian cysts, and breast secretion. Of the 27 patients with negative {sup 201}Tl and {sup 131}I

  7. Prognostic value of transient ischemic dilation with regadenoson myocardial perfusion imaging.

    Science.gov (United States)

    Lester, Davis; El-Hajj, Stephanie; Farag, Ayman A; Bhambhvani, Pradeep; Tauxe, Lindsey; Heo, Jaekyeong; Iskandrian, Ami E; Hage, Fadi G

    2016-10-01

    Transient ischemic dilation (TID) of the left ventricle seen on myocardial perfusion imaging (MPI) is sometimes used as a marker of severe coronary artery disease. The prognostic value of TID obtained using regadenoson, a selective adenosine A2A receptor agonist, as a stress agent for MPI has not been studied. TID ratio was measured using an automated software program on consecutive patients with normal and abnormal perfusion pattern on regadenoson MPI at a single institution. An abnormal TID was defined as greater than 1.33. The primary outcome was a composite of cardiac death, non-fatal myocardial infarction (MI), and late coronary revascularization (CR, >90 days after MPI). The study population consisted of 887 patients (62 ± 12 years, 66% male, 48% diabetes, 46% prior CR, 75% with abnormal perfusion pattern, left ventricular ejection fraction-LVEF 55 ± 6%). An abnormal TID was present in 51 (6%) patients. Baseline characteristics were not different based on the presence or absence of TID. Early CR (≤90 days) was performed in 11 (22%) patients with vs 92 (11%) patients without TID (P = .04). During a mean follow-up of 29 ± 19 months, the primary outcome occurred in 271 (31%) patients (22% cardiac death, 6% MI, 9% late CR). TID was associated with increased risk of the primary outcome (log-rank P = .017), an association largely driven by late CR. In a Cox proportional model adjusted for multiple variables including perfusion defect size (PDS) and LVEF, the hazard ratio for TID was 1.92 (95% CI 1.20-3.08, P = .007). In the subset of patients with normal perfusion pattern, there was no association between TID and outcomes. TID on regadenoson MPI carries important prognostic information that is independent from PDS and LVEF, but this association is restricted to patients with abnormal perfusion on imaging.

  8. Case of right ventricular infarction identified by sup(99m)Tc-PYP myocardial imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kawamura, Akiyoshi; Nakai, Kenji; Matsushita, Kazuo (Iwate Medical Coll., Morioka (Japan). School of Medicine)

    1982-06-01

    A case of 53-year-old-man with myocardial infarction accompanied by right ventricular infarction assessed by Tc-99m-PYP scintiscan was reported. Patient was admitted to our clinic because of sudden chest pain and Adames-Stokes attack. At the time of admission he was pre-shock state and cold sweating was markedly noted in the lower extremities. ECG revealed complete A-V block with ST elevation in II, III, aV sub(F). Chest X-ray film showed cardiomegaly and lung congestion. CVP was high (22 cm H/sub 2/O) and cardiac output was low (2.4 L/min). Marked elevation of SGOT, LDH and CPK was also noted. After administration of 20 mCi of Tc-99m-PYP, myocardial scintiscan revealed a positive accumulation, which continued for 80 days, in accordant with anterior portion of the right ventricle. From these findings, right ventricular infarction was clinicaly suspected. Combined therapy with dopamine (10 ..gamma../kg/min) and vasodilator and blood transfusion was effective in this patient. At the 60th day after admission, this patient had been recovered: Thallium-201 myocardial scintigraphy showed a perfusion defect in the inferior region. Total obstruction of RCA and diffuse stenosis of LAD were observed on CAG. Akinesis of inferoposterior region was found in the left ventriculogram. Tc-99m-PYP scintiscan in acute phase was a useful method in detecting of right ventricular infarction. Continued of positive accumulation of Tc-99m-PYP scintiscan suggested a possibility of aneurysmal formation of the right ventricle.

  9. Relation between myocardial damage and disease activity in patients with systemic lupus erythematosus by exercise {sup 201}Tl scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Kuzumoto, Masayuki [Nara Medical Univ. (Japan)

    1997-08-01

    Myocardial damage in patients with systemic lupus erythematosus (SLE) was evaluated using exercise thallium-201 myocardial scintigraphy, and the relationship between myocardial damage and disease activity of SLE was examined. Twenty-seven patients (26 women and 1 man, mean age 43 years), in whom extramural coronary artery lesions were excluded by coronary angiogram or presumed to be excluded by exercise electrocardiogram, were enrolled in this study. The mean duration of disease and the mean duration of corticosteroid therapy in these patients were 94 and 77 months, respectively. Exercise thallium-201 scintigraphy was performed twice (mean interval, 30 months) to evaluate the progression of myocardial damage. Myocardial ischemia as an index of myocardial damage was evaluated by visual analysis and ischemic score (IS). The changes in myocardial ischemia were categorized into 3 groups: improved, unchanged or worsened. The disease activity of SLE was determined by the SLE Disease Activity Index (SLEDAI), and the changes in this index were classified into the same three categories, as evaluated every six months between the two scintigraphic examinations. Disease activity was significantly correlated with myocardial ischemia (p<0.05), and with myocardial ischemia as diagnosed by {Delta}IS (difference in ischemic score between the first and second thallium-201 scintigrams: p<0.005). But neither the duration of disease nor the duration of corticosteroid therapy was correlated with IS at the first scintigraphy. These results indicate that control of SLE disease activity may be critical in the treatment of myocardial damage resulting from vascular lesions, especially intramyocardial small-artery disease, in patients with SLE. (author)

  10. Fully automated framework for the analysis of myocardial first-pass perfusion MR images.

    Science.gov (United States)

    Beache, Garth M; Khalifa, Fahmi; El-Baz, Ayman; Gimel'farb, Georgy

    2014-10-01

    To develop an automated framework for accurate analysis of myocardial perfusion using first-pass magnetic resonance imaging. The proposed framework consists of four processing stages. First, in order to account for heart deformations due to respiratory motion and heart contraction, a two-step registration methodology is proposed, which has the ability to account for the global and local motions of the heart. The methodology involves an affine-based registration followed by a local B-splines alignment to maximize a new similarity function based on the first- and second-order normalized mutual information. Then the myocardium is segmented using a level-set function, its evolution being constrained by three features, namely, a weighted shape prior, a pixelwise mixed object/background image intensity distribution, and an energy of a second-order binary Markov-Gibbs random field spatial model. At the third stage, residual segmentation errors and imperfection of image alignment are reduced by employing a Laplace-based registration refinement step that provides accurate pixel-on-pixel matches on all segmented frames to generate accurate parametric perfusion maps. Finally, physiology is characterized by pixel-by-pixel mapping of empirical indexes (peak signal intensity, time-to-peak, initial upslope, and the average signal change of the slowly varying agent delivery phase), based on contrast agent dynamics. The authors tested our framework on 24 perfusion data sets from 8 patients with ischemic damage who are undergoing a novel myoregeneration therapy. The performance of the processing steps of our framework is evaluated using both synthetic and in-vivo data. First, our registration methodology is evaluated using realistic synthetic phantoms and a distance-based error metric, and an improvement of registration is documented using the proposed similarity measure (P-value ≤10(-4)). Second, evaluation of our segmentation using the Dice similarity coefficient, documented an

  11. Assessment of the effect of revascularization early after CABG using ECG-gated perfusion single-photon emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kubo, Shigeto; Tadamura, Eiji; Kudoh, Takashi; Inubushi, Masayuki; Konishi, Junji [Dept. of Nuclear Medicine and Diagnostic Imaging, Kyoto University Graduate (Japan); Ikeda, Tadashi; Koshiji, Takaaki; Nishimura, Kazunobu; Komeda, Masashi [Dept. of Cardiovascular Surgery, Kyoto University (Japan); Tamaki, Nagara [Dept. of Nuclear Medicine, Hokkaido University, Sapporo (Japan)

    2001-02-01

    When an arterial graft is used, reversible perfusion defects on single-photon emission tomography (SPET) perfusion images are occasionally observed early after coronary artery bypass graft surgery (CABG), owing to the restricted flow capacity. The purpose of this study was to determine whether the functional information obtained with electrocardiography (ECG)-gated perfusion SPET could be helpful in evaluating the effect of revascularization early after CABG. Twenty-three patients (18 men and 5 women, mean age 65{+-}9 years) underwent stress/re-injection thallium-201 ECG-gated SPET before and 4 weeks after CABG (13 with exercise and 10 with dipyridamole). Patency of all grafts was confirmed by coronary angiography 1 month after CABG. Cardiac functional data including the left ventricular ejection fraction (LVEF) and the transient ischaemic dilatation (TID) ratio were analysed using a commercially available automated program. The conventional stress and re-injection tomograms were interpreted by means of a five-point scoring system in a nine-segment model. Stress-induced reversible {sup 201}Tl perfusion defects were present in 64% of the myocardial segments bypassed by patent arterial grafts, in contrast to 42% of the myocardial segments bypassed by patent venous grafts ({chi}{sup 2}=7.8, P=0.005). Of the 23 patients, 12 showed improvement in summed ischaemic scores (group 1), while 11 had no change or deterioration (group 2), although all grafts were patent on postoperative catheterization. The TID ratio improved in both group 1 and group 2 before and after CABG (1.14{+-}0.13 vs 0.99{+-}0.07, P=0.001 and 1.09{+-}0.07 vs 0.94{+-}0.05, P=0.002, respectively). However, LVEF did not significantly improve in group 1 or group 2 after CABG (42.5%{+-}9.9% vs 47.5%{+-}11.8%, and 52.1%{+-}7.5% vs 53.1%{+-}5.9%, respectively). Perfusion imaging or LVEF assessment is of limited value early after CABG. The TID ratio obtained with ECG-gated perfusion SPET may be a useful marker

  12. Current concepts relating coronary flow, myocardial perfusion and metabolism in left bundle branch block and cardiac resynchronisation therapy.

    Science.gov (United States)

    Claridge, Simon; Chen, Zhong; Jackson, Tom; Sammut, Eva; Sohal, Manav; Behar, Jonathan; Razavi, Reza; Niederer, Steven; Rinaldi, Christopher Aldo

    2015-02-15

    Cardiac resynchronisation therapy (CRT) improves mortality and symptoms in heart failure patients with electromechanically dyssynchronous ventricles. There is a 50% non-response rate and reproducible biomarkers to predict non-response have not been forthcoming. Therefore, there has been increasing interest in the pathophysiological effects of dyssynchrony particularly focusing on coronary flow, myocardial perfusion and metabolism. Studies suggest that dyssynchronous electrical activation effects coronary flow throughout the coronary vasculature from the epicardial arteries to the microvascular bed and that these changes can be corrected by CRT. The effect of both electrical and mechanical dyssynchrony on myocardial perfusion is unclear with some studies suggesting there is a reduction in septal perfusion whilst others propose that there is an increase in lateral perfusion. Better understanding of these effects offers the possibility for better prediction of non-response. CRT appears to improve homogeneity in myocardial perfusion where heterogeneity is described in the initial substrate. Novel approaches to the identification of non-responders via metabolic phenotyping both invasively and non-invasively have been encouraging. There remains a need for further research to clarify the interaction of coronary flow with perfusion and metabolism in patients who undergo CRT. Crown Copyright © 2014. Published by Elsevier Ireland Ltd. All rights reserved.

  13. Semi-quantitative myocardial perfusion measured by computed tomography in patients with refractory angina

    DEFF Research Database (Denmark)

    Qayyum, Abbas Ali; Kühl, Jørgen Tobias; Kjaer, Andreas

    2017-01-01

    scanner and CT/PET 64-slice scanner. CT measured myocardial attenuation density (AD) and perfusion index (PI) were correlated to absolute PET myocardial perfusion values. RESULTS: Rest AD, rest and stress PI did not correlate to PET findings (r = 0·412, P = 0·113; r = 0·300, P = 0·259; and r = 0·508, P...... = 0·064, respectively). However, there was a significant correlation between stress AD and stress PET values (r = 0·670, P = 0·009) and between stress and rest differences for AD and PI with PET differences (r = 0·620, P = 0·006; and r = 0·639, P = 0·004, respectively). Furthermore, significant...... differences were observed between remote and stenotic territories for rest and stress AD (48 ± 14HU and 37 ± 16HU, P = 0·002; 76 ± 19HU and 58 ± 13HU, PPI (9·6 ± 2·9 and 7·5 ± 3·1, P = 0·002; 21·6 ± 4·1 and 16·9 ± 3·9, P

  14. Myocardial perfusion scintigraphy fi ndings in patients with mild coronary atherosclerotic lesions on coronary angiography

    Directory of Open Access Journals (Sweden)

    Zeki Dostbil

    2010-09-01

    Full Text Available Objectives: Myocardial perfusion scintigraphy (MPS iswidely used in functional assessment of myocardial per-fusion. But, some study results are in contradiction withseverity of coronary artery disease detected by coronaryangiography (CA. It is frequently encountered case thatCA is completely normal whereas MPS describes isch-emia. In this study, we aimed to investigate whether mildatherosclerotic lesions cause ischemia.Materials and methods: MPS with 99mTc-MIBI was per-formed in 52 patients who applied to cardiology clinics forhistory of chest pain and underwent diagnostic CA within3 months.Results: In 22 of 52 patients with mild atherosclerotic le-sions, ischemia in various degrees was detected on MPS.In statistical analysis, any signifi cant relationship was notfound between ischemia and gender, hypertension, DM,dyslipidemia, smoking, mitral valve insuffi ciency, left ven-tricular hypertrophy, exercise testing result and affectedcoronary artery.Conclusion: Our study fi ndings have shown that mild ath-erosclerotic lesions even at very early stage may causemyocardial ischemia

  15. Comparison of the prognostic value of regadenoson and adenosine myocardial perfusion imaging.

    Science.gov (United States)

    Farzaneh-Far, Afshin; Shaw, Linda K; Dunning, Allison; Oldan, Jorge D; O'Connor, Christopher M; Borges-Neto, Salvador

    2015-08-01

    Regadenoson is now widely used in single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI). However, the prognostic value of abnormal stress perfusion findings with regadenoson vs adenosine are unclear. The aim of this study was to evaluate the prognostic value of regadenoson SPECT and to compare it to that of adenosine SPECT. 3698 consecutive patients undergoing either adenosine or regadenoson SPECT were assessed at 1 year for the endpoints of cardiovascular death and a composite endpoint of cardiovascular death or MI. Weighted Cox proportional hazards regression modeling with the inverse probability weighted (IPW) estimators method adjusting to propensity for agent was used to account for differences in baseline characteristics. Patients undergoing adenosine SPECT MPI had a significantly higher prevalence of smoking history, diabetes, hypertension, and prior myocardial infarction (P regadenoson SPECT MPI is a significant predictor of events and provides incremental prognostic information beyond basic clinical variables. We have shown for the first time that use of regadenoson vs adenosine as stress agent does not modify the prognostic significance of SSS. Similar findings were seen with SDS.

  16. Myocardial Perfusion SPECT Imaging in Dextrocardia with Situs Inversus: A Case Report.

    Science.gov (United States)

    Ayeni, Olusegun Akinwale; Malan, Nico; Hammond, Emmanuel Niiboye; Vangu, Mboyo-Di-Tamba Heben

    2016-01-01

    Dextrocardia is a cardiac positional anomaly in which the heart is located in the right hemithorax with its base-to-apex axis directed to the right and caudad. Situs inversus is an autosomal recessive disorder that causes organs in the chest and abdomen to be positioned in a mirror image from their normal position. Dextrocardia may occur in isolation or as part of situs inversus. Similarly, situs inversus may occur with or without dextrocardia. Situs inversus accompanied with dextrocardia (situs inversus totalis) is a rare congenital abnormality occurring in 0.01% of live births. Herein, we present the case of a 35-year-old man with previously diagnosed situs inversus totalis with mirror-image dextrocardia, referred to our facility for diagnosis of coronary artery disease (CAD). The incidence and presentation of CAD in patients with dextrocardia are similar to the normal population. However, considerable attention should be paid to the acquisition of myocardial perfusion scintigraphy and data processing/analysis in this group of patients. The present case highlights the distinctive applications and potential pitfalls of myocardial perfusion single-photon emission computed tomography (SPECT) imaging in patients with dextrocardia.

  17. Myocardial Perfusion SPECT Imaging in Dextrocardia with Situs Inversus: A Case Report

    Directory of Open Access Journals (Sweden)

    Olusegun Akinwale Ayeni

    2016-07-01

    Full Text Available Dextrocardia is a cardiac positional anomaly in which the heart is located in the right hemithorax with its base-to-apex axis directed to the right and caudad. Situs inversus is an autosomal recessive disorder that causes organs in the chest and abdomen to be positioned in a mirror image from their normal position. Dextrocardia may occur in isolation or as part of situs inversus. Similarly, situs inversus may occur with or without dextrocardia. Situs inversus accompanied with dextrocardia (situs inversus totalis is a rare congenital abnormality occurring in 0.01% of live births. Herein, we present the case of a 35-yearold man with previously diagnosed situs inversus totalis with mirror-image dextrocardia, referred to our facility for diagnosis of coronary artery disease (CAD. The incidence and presentation of CAD in patients with dextrocardiaare similar to the normal population. However, considerable attention should be paid to the acquisition of myocardial perfusion scintigraphy and data processing/analysis in this group of patients. The present case highlights thedistinctive applications and potential pitfalls of myocardial perfusion single photon emission computed tomography (SPECT imaging in patients with dextrocardia.

  18. An unsupervised approach for measuring myocardial perfusion in MR image sequences

    Science.gov (United States)

    Discher, Antoine; Rougon, Nicolas; Preteux, Francoise

    2005-08-01

    Quantitatively assessing myocardial perfusion is a key issue for the diagnosis, therapeutic planning and patient follow-up of cardio-vascular diseases. To this end, perfusion MRI (p-MRI) has emerged as a valuable clinical investigation tool thanks to its ability of dynamically imaging the first pass of a contrast bolus in the framework of stress/rest exams. However, reliable techniques for automatically computing regional first pass curves from 2D short-axis cardiac p-MRI sequences remain to be elaborated. We address this problem and develop an unsupervised four-step approach comprising: (i) a coarse spatio-temporal segmentation step, allowing to automatically detect a region of interest for the heart over the whole sequence, and to select a reference frame with maximal myocardium contrast; (ii) a model-based variational segmentation step of the reference frame, yielding a bi-ventricular partition of the heart into left ventricle, right ventricle and myocardium components; (iii) a respiratory/cardiac motion artifacts compensation step using a novel region-driven intensity-based non rigid registration technique, allowing to elastically propagate the reference bi-ventricular segmentation over the whole sequence; (iv) a measurement step, delivering first-pass curves over each region of a segmental model of the myocardium. The performance of this approach is assessed over a database of 15 normal and pathological subjects, and compared with perfusion measurements delivered by a MRI manufacturer software package based on manual delineations by a medical expert.

  19. Diagnostic and prognostic role of myocardial perfusion scintigraphy in kidney transplant candidates: narrative review

    Directory of Open Access Journals (Sweden)

    Alberto Bestetti

    2016-10-01

    Full Text Available PurposeCardiac screening in adult kidney transplant candidates with myocardial perfusion scintigraphy (MPS can reveal findings associated with increased risk for coronary heart disease events, but the exact value of this screening test is still undetermined.MethodsNarrative review based on the available literature and guidelines on the yield, benefits, and harms of MPS screening in kidney transplant candidates.ResultsAlthough coronary angiography carries low risk in general population, it is not without risk particularly in patients with complex comorbid disease and the use of intravenous contrast media may precipitate a need for hospitalization and death. We could avoid invasive coronary angiography in patients with chronic kidney disease, although with high coronary calcium score, but good left ventricle function and normal perfusion, evaluated by Gated single-photon emission computed tomographic (SPECT MPS. In fact, although Gated SPECT MPS has not a high sensitivity, it provides some variables that are closely related to sudden death: post-stress and rest-ejection fraction and left ventricular volumes, left ventricle muscle mass, extent of ischemia and scar.ConclusionsGated SPECT MPS is a valid noninvasive cardiac screening test. It can be used as alternative to stress echocardiography in kidney transplant candidates with high cardiovascular risk and a positive or inconclusive exercise tolerance ECG test.Patients with abnormal perfusion and cardiac dysfunction should undergo invasive coronary artery imaging and endovascular treatment, while angiography could be avoided in patients with normal MPI, having good long-term prognosis.

  20. Effect of Chinese drugs for supplementing Qi, nourishing Yin and activating blood circulation on myocardial perfusion in patients with acute myocardial infarction after revascularization.

    Science.gov (United States)

    Li, Yong-Qiang; Jin, Mei; Qiu, Sheng-Lei; Wang, Pei-Li; Zhu, Tian-Gang; Wang, Cheng-Long; Li, Tian-Chang; Liu, Hong-Xu; Bian, Hong; Yao, Li-Fang; Shi, Da-Zhuo

    2009-02-01

    To observe the effects of Chinese drugs for supplementing qi, nourishing yin and activating blood circulation on the myocardial perfusion in acute myocardial infarction (AMI) patients after revascularization. Eighty patients with anterior or inferior ventricular wall AMI, who had received revascularization by intravenous thrombolysis or coronary bypass, were randomized into the treated group and the control group equally, both treated with conventional Western medical treatment, but combined, respectively, with Xinyue Capsule (, XYC) plus Composite Salvia Tablet (CST) and placebo for 3 months. Dobutamine stress echocardiography (DSE) was performed 14 days and 3 months after revascularization, respectively on every patient to observe blood perfusion extent (b value), myocardial perfusion velocity (k value) and local blood fl ow volume (k x b) in left ventricular infarction-related vascular segments under stressed state. With 5 cases dropping out in the observation period (3 in the treated group and 2 in the control group), the trial was completed in 75 patients in total. The 14-day DSE shows that the b value and k x b value of left anterior ventricular wall mid segment and apex segment, and the k value of apex segment in patients with anterior wall AMI, as well as the b value and k x b of basal segment in patients with inferior wall AMI in the treated group were significantly higher than those in the control group (Pcirculation in combination with conventional Western medical treatment could obviously improve the blood perfusion at the myocardial tissue level in infarction-related vascular segments.

  1. Endotoxaemic myocardial dysfunction: the role of coronary driving pressure in subendocardial perfusion.

    Science.gov (United States)

    Lorigados, Clara B; Ariga, Suely K; Batista, Tiago R; Velasco, Irineu T; Soriano, Francisco G

    2015-03-01

    To investigate the role of coronary driving pressure (CDP) in myocardial microcirculatory blood flow during sepsis. We hypothesised that in septic shock there is an impaired autoregulation of microcirculation, and blood flow is totally dependent on CDP. We analysed the effect of lipopolysaccharide (LPS)-induced shock on myocardial microcirculation, separating subendocardial and epicardial areas. We then studied the effect of CDP increases using noradrenaline (NOR) or metaraminol (Aramine [ARA]) on myocardial microcirculation and function, and we analysed the effect of volume infusion on CDP and myocardial function. Endotoxaemia was induced in male Wistar rats by an intraperitoneal injection of LPS 10 mg/kg. Animals were divided into a control (CT) group, an LPS-injected group, and an LPS-injected group treated with saline fluid, NOR or ARA. Ninety minutes later, a haemodynamic evaluation was performed. NOR or ARA were used to manage the mean arterial pressure (MAP) and CDP, and we inserted a catheter into the left ventricle to measure cardiac parameters. To measure blood flow in the myocardium and other organs, microspheres were introduced into the left ventricle using an infusion pump. After LPS treatment, left ventricular (LV) systolic function (dP/dt max) and diastolic function (dP/dt min) decreased by 34% and 15%, respectively, and load-independent indices (LV contractility in ejection phase and dP/dt max÷end-diastolic volume) were reduced. The CDP was also reduced (by 58%) in the endotoxaemic rats. Myocardial blood flow was reduced (by 80%) in animals with an MAP≤65 mmHg. NOR increased the CDP (LPS, 38 mmHg [SEM, 2 mmHg]; LPS+NOR, 59 mmHg [SEM, 3 mmHg]) and microcirculatory perfusion (LPS, 2 mL/min/g tissue [SEM, 0.6 mL/min/g]; LPS+NOR, 6.2 mL/min/g [SEM, 0.8 mL/min/g]). ARA was also effective in improve microcirculation but saline volume infusion was ineffective in improving CDP or myocardial function. CDP showed a significant correlation with

  2. Quantitative myocardial perfusion PET parametric imaging at the voxel-level

    Science.gov (United States)

    Mohy-ud-Din, Hassan; Lodge, Martin A.; Rahmim, Arman

    2015-08-01

    Quantitative myocardial perfusion (MP) PET has the potential to enhance detection of early stages of atherosclerosis or microvascular dysfunction, characterization of flow-limiting effects of coronary artery disease (CAD), and identification of balanced reduction of flow due to multivessel stenosis. We aim to enable quantitative MP-PET at the individual voxel level, which has the potential to allow enhanced visualization and quantification of myocardial blood flow (MBF) and flow reserve (MFR) as computed from uptake parametric images. This framework is especially challenging for the 82Rb radiotracer. The short half-life enables fast serial imaging and high patient throughput; yet, the acquired dynamic PET images suffer from high noise-levels introducing large variability in uptake parametric images and, therefore, in the estimates of MBF and MFR. Robust estimation requires substantial post-smoothing of noisy data, degrading valuable functional information of physiological and pathological importance. We present a feasible and robust approach to generate parametric images at the voxel-level that substantially reduces noise without significant loss of spatial resolution. The proposed methodology, denoted physiological clustering, makes use of the functional similarity of voxels to penalize deviation of voxel kinetics from physiological partners. The results were validated using extensive simulations (with transmural and non-transmural perfusion defects) and clinical studies. Compared to post-smoothing, physiological clustering depicted enhanced quantitative noise versus bias performance as well as superior recovery of perfusion defects (as quantified by CNR) with minimal increase in bias. Overall, parametric images obtained from the proposed methodology were robust in the presence of high-noise levels as manifested in the voxel time-activity-curves.

  3. Double-gated myocardial ASL perfusion imaging is robust to heart rate variation.

    Science.gov (United States)

    Do, Hung Phi; Yoon, Andrew J; Fong, Michael W; Saremi, Farhood; Barr, Mark L; Nayak, Krishna S

    2017-05-01

    Cardiac motion is a dominant source of physiological noise (PN) in myocardial arterial spin labeled (ASL) perfusion imaging. This study investigates the sensitivity to heart rate variation (HRV) of double-gated myocardial ASL compared with the more widely used single-gated method. Double-gating and single-gating were performed on 10 healthy volunteers (n = 10, 3F/7M; age, 23-34 years) and eight heart transplant recipients (n = 8, 1F/7M; age, 26-76 years) at rest in the randomized order. Myocardial blood flow (MBF), PN, temporal signal-to-noise ratio (SNR), and HRV were measured. HRV ranged from 0.2 to 7.8 bpm. Double-gating PN did not depend on HRV, while single-gating PN increased with HRV. Over all subjects, double-gating provided a significant reduction in global PN (from 0.20 ± 0.15 to 0.11 ± 0.03 mL/g/min; P = 0.01) and per-segment PN (from 0.33 ± 0.23 to 0.21 ± 0.12 mL/g/min; P < 0.001), with significant increases in global temporal SNR (from 11 ± 8 to 18 ± 8; P = 0.02) and per-segment temporal SNR (from 7 ± 4 to 11 ± 12; P < 0.001) without significant difference in measured MBF. Single-gated myocardial ASL suffers from reduced temporal SNR, while double-gated myocardial ASL provides consistent temporal SNR independent of HRV. Magn Reson Med 77:1975-1980, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  4. Microheterogeneity of regional myocardial blood flows in low-perfused rat hearts evaluated by double-tracer digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Takeshi [Bioengineering Division, Osaka University Graduate School of Engineering Science, Machikaneyamacho 13, Toyonaka 5608531 (Japan)]. E-mail: matsu@me.es.osaka-u.ac.jp; Asano, Takahisa [Department of Medical Engineering and Systems Cardiology, Kawasaki Medical School Matsushima 577, Kurashiki 7010192 (Japan); Takemoto, Mami [Department of Medical Engineering and Systems Cardiology, Kawasaki Medical School Matsushima 577, Kurashiki 7010192 (Japan); Tachibana, Hiroyuki [Department of Medical Engineering and Systems Cardiology, Kawasaki Medical School Matsushima 577, Kurashiki 7010192 (Japan); Ogasawara, Yasuo [Department of Medical Engineering and Systems Cardiology, Kawasaki Medical School Matsushima 577, Kurashiki 7010192 (Japan); Kajiya, Fumihiko [Department of Medical Engineering and Systems Cardiology, Kawasaki Medical School Matsushima 577, Kurashiki 7010192 (Japan)

    2007-08-15

    Using {sup 3}H- and {sup 125}I-labeled desmethylimipramine (DMI) for regional flow tracers, we established a two-time measurement method for the spatial pattern of myocardial perfusion in cross-circulated rat hearts. Myocardial extractions and retentions of these tracers were confirmed to be satisfactory; however, the latter were less than 90% after 3 min at a perfusion rate of 2.9 ml/min/g, limiting the present application to a short-time perfusion measurement. Distributions of myocardial depositions were separated by subtraction digital radiography with 400-{mu}m pixel resolution. Its feasibility was examined by regression analysis between local deposition densities of {sup 3}H- and {sup 125}I-DMI injected simultaneously. The slope, y-intercept, and correlation coefficient (r) of the regression line were 0.98{+-}0.04, 0.02{+-}0.04, and 0.95{+-}0.03, respectively, indicating the validity of the present image subtraction technique. The spatial pattern of myocardial perfusion in response to flow reduction was evaluated by the injections of {sup 3}H- and {sup 125}I-DMI, respectively, before and after a nearly 70% flow reduction. A significant correlation between normalized density distributions of these tracers was found in both subepicardium (r=0.77{+-}0.12) and subendocardium (r=0.73{+-}0.20), indicating the stable pattern of myocardial perfusion. However, the coefficient of variation of tracer densities showed a decrease of subendocardial flow heterogeneity from 35{+-}15% to 31{+-}16%. Thus, flow differences between originally high- and low-flow regions in subendocardium were reduced on a relative basis during low perfusion.

  5. The Myocardial Perfusion Scintigraphy in Predicting Risk for Coronary Artery Disease in Patients with Anxiety and Depression Symptoms

    Directory of Open Access Journals (Sweden)

    Billur Çalışkan

    2016-06-01

    Full Text Available INTRODUCTION: An association between psychological factors and cardiovascular disease, has long been suspected. However it is not clear whether chest pain is caused by emotional distress or whether coronary spasms are caused by the onset of coronary artery disease (CAD. We aimed to predict the risk for CAD in patients referred to myocardial perfusion imaging (MPI with chest pain using depression, stress, and anxiety symptoms. METHODS: The emotional status of all patients was evaluated using the Hospital Anxiety and Depression Scale (HADS-A and HADS-D, the State and Trait Anxiety Inventory (STAI-1 and STAI-2, the Perceived Stress Scale (PSS, and the Anxiety Sensitivity Index-3 (ASI. Myocardial perfusion was measured using a 17-segment model and 5-point scoring system (0: normal perfusion; 4: no perfusion. RESULTS: MPI revealed reversible perfusion defects in 24 of 141 patients and no perfusion defects in 117 patients. The STAI-2 and HADS-A and HADS-D scores were significantly higher in patients with myocardial ischemia than in those without (STAI-2: 50.8 ± 7.5 vs. 46.3 ± 7.1, respectively; p = 0.008; HADS-A: 9.5 ± 3.9 vs. 7.8 ± 3.4, respectively; p = 0.033; HADS-D: 8.7 ± 3.0 vs. 7.3 ± 3.0, respectively; p = 0.05. Unadjusted correlation analysis showed that there was statistically significant correlation between reversible perfusion defects and anxiety scores (r=0.186, p= 0.029. DISCUSSION AND CONCLUSION: The patients with symptoms of depression and high-trait anxiety may be at higher risk of myocardial ischemia than patients without such symptoms. Thus, the emotional status of patients should be taken into consideration during clinical evaluation for CAD.

  6. Exercise myocardial perfusion scintigraphy is useful for evaluating myocardial ischemia even in the elderly

    Energy Technology Data Exchange (ETDEWEB)

    Kurata, Chinori; Uehara, Akihiko; Sugi, Toshihiko; Yamazaki, Keisuke [Hamamatsu Univ. School of Medicine, Shizuoka (Japan); Tawarahara, Kei; Mikami, Tadashi; Matoh, Fumitaka; Odagiri, Keiichi

    2000-06-01

    Pharmacologic stress testing is recommended to elderly patients as a valuable alternative to exercise testing. We examined whether exercise testing is as useful for evaluating myocardial ischemia in the elderly as in the young. The consecutive 1,508 patients who underwent exercise {sup 201}Tl single-photon emission computed tomography (SPECT) were divided into six age groups: 6-29 years (n=56), 30-44 (n=143), 45-54 (n=311), 55-64 (n=498), 65-74 (n=402), and 75-88 (n=98). Both heart rate and rate-pressure product at peak exercise were significantly lower in patients aged 75-88 than in the other five groups. The frequency of ischemic ST depression was higher in patients aged 75-88 than in those aged 6-74, although the difference was not significant. Moreover, the frequency of {sup 201}Tl transient defect was significantly higher in patients aged 75-88 than in those aged 6-74. On the other hand, the sensitivity of ischemic ST depression for {sup 201}Tl transient defect was similar among the six groups, but the specificity was significantly lower in patients aged 75-88 than in those aged 6-74. In conclusion, exercise {sup 201}Tl SPECT is useful for evaluating myocardial ischemia even in the elderly, but exercise electrocardiography has limitations such as lower specificity in the elderly than {sup 201}Tl SPECT. (author)

  7. Determinants of coronary flow reserve in non-diabetic patients with chest pain without myocardial perfusion defects.

    Directory of Open Access Journals (Sweden)

    Helena U Westergren

    Full Text Available Microvascular dysfunction could be responsible for chest pain in patients without myocardial perfusion defects. We evaluated microvascular function using ultrasound-assessed coronary flow reserve (CFR in patients with chest pain and normal myocardial perfusion scintigram. Secondly, we investigated association between cardiovascular parameters and decreased CFR in a sex specific manner.A total of 202 (128 women non-diabetic patients with chest pain and suspected myocardial ischemia, but without myocardial perfusion defects on myocardial perfusion scintigram, were enrolled and underwent CFR examination and blood sampling. All patients were followed-up for cardiovascular events. We used a supervised principal component analysis including 66 variables such as clinical parameters, ongoing medication, coronary artery disease history, lipids, metabolic parameters, inflammatory and other cardiovascular parameters.During a median follow-up time of 5.4 years, 25 cardiovascular events occurred; (men;18, women;7. Average CFR of the study cohort was 2.7±1.2 and 14% showed impaired CFR<2.0. In an adjusted Cox regression analysis, CFR<2.0 independently predicted event-free survival (HR:2.5, p = 0.033. In the supervised principal component analysis high insulin resistance assessed by Homeostatic model assessment for insulin resistance was the strongest biochemical marker associated with decreased CFR. Interestingly, upon sex specific multivariable linear regression analysis, the association was only significant in men (β = -0.132, p = 0.041 while systolic blood pressure remained an independent predictor in women (β = -0.009, p = 0.011.In non-diabetic patients with chest pain without myocardial perfusion defects, low CFR has prognostic value for future cardiovascular events. Insulin resistance appears to be a marker for decreased CFR in men. Indeed, in the context of contribution of traditional risk factors in this patient population, the value of systolic

  8. Measurement of extracellular volume and transit time heterogeneity using contrast-enhanced myocardial perfusion MRI in patients after acute myocardial infarction.

    Science.gov (United States)

    Kunze, Karl P; Rischpler, Christoph; Hayes, Carmel; Ibrahim, Tareq; Laugwitz, Karl-Ludwig; Haase, Axel; Schwaiger, Markus; Nekolla, Stephan G

    2017-06-01

    To assess the ability of dynamic contrast-enhanced myocardial perfusion MRI to measure extracellular volume (ECV) and to investigate the possibility of estimating capillary transit time heterogeneity (CTH) in patients after myocardial infarction and successful revascularization. Twenty-four perfusion data sets were acquired on a 3 Tesla positron emission tomography (PET)/MRI scanner. Three perfusion models of different complexity were implemented in a hierarchical fashion with an Akaike information criterion being used to determine the number of fit parameters supported by the data. Results were compared sector-wise to ECV from an equilibrium T1 mapping method (modified look-locker inversion recovery (MOLLI)). ECV derived from the perfusion analysis correlated well with equilibrium measurements (R² = 0.76). Estimation of CTH was supported in 16% of sectors (mostly remote). Inclusion of a nonzero CTH parameter usually led to lower estimates of first-pass extraction and slightly higher estimates of blood volume and flow. Estimation of the capillary permeability-surface area product was feasible in 81% of sectors. Transit time heterogeneity has a measurable effect on the kinetic analysis of myocardial perfusion MRI data, and Gd-DTPA extravasation in the myocardium is usually not flow-limited in infarct-related pathology. Measurement of myocardial ECV using perfusion imaging could provide a scan-time efficient alternative to methods based on T1 mapping. Magn Reson Med 77:2320-2330, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  9. A tourniquet assisted cardiopulmonary resuscitation augments myocardial perfusion in a porcine model of cardiac arrest.

    Science.gov (United States)

    Yang, Zhengfei; Tang, David; Wu, Xiaobo; Hu, Xianwen; Xu, Jiefeng; Qian, Jie; Yang, Min; Tang, Wanchun

    2015-01-01

    During cardiopulmonary resuscitation (CPR), myocardial blood flow generated by chest compression rarely exceeds 35% of its normal level. Cardiac output generated by chest compression decreases gradually with the prolongation of cardiac arrest and resuscitation. Early studies have demonstrated that myocardial blood flow during CPR is largely dependent on peripheral vascular resistance. In this study, we investigated the effects of chest compression in combination with physical control of peripheral vascular resistance assisted by tourniquets on myocardial blood flow during CPR. Ventricular fibrillation was induced and untreated for 7 min in ten male domestic pigs weighing between 33 and 37 kg. The animals were then randomized to receive CPR alone or a tourniquet assisted CPR (T-CPR). In the CPR alone group, chest compression was performed by a miniaturized mechanical chest compressor. In the T-CPR group, coincident with the start of resuscitation, the thin elastic tourniquets were wrapped around the four limbs from the distal end to the proximal part. After 2 min of CPR, epinephrine (20 μg/kg) was administered via the femoral vein. After 5 min of CPR, defibrillation was attempted by a single 150 J shock. If resuscitation was not successful, CPR was resumed for 2 min before the next defibrillation. The protocol was continued until successful resuscitation or for a total of 15 min. Five minutes after resuscitation, the elastic tourniquets were removed. The resuscitated animals were observed for 2h. T-CPR generated significantly greater coronary perfusion pressure, end-tidal carbon dioxide and carotid blood flow. There was no difference in both intrathoracic positive and negative pressures between the two groups. All animals were successfully resuscitated with a single shock in both groups. There were no significant changes in hemodynamics observed in the animals treated in the T-CPR group before-and-after the release of tourniquets at post-resuscitation 5 min. T

  10. Myocardial perfusion scintigraphy 2007 in Germany. Results of the query and current status

    Energy Technology Data Exchange (ETDEWEB)

    Lindner, O. [Inst. fuer Radiologie, Nuklearmedizin und Molekulare Bildgebung, Herz- und Diabeteszentrum NRW, Bad Oeynhausen (Germany); Burchert, W. [Inst. fuer Radiologie, Nuklearmedizin und Molekulare Bildgebung, Herz- und Diabeteszentrum NRW, Bad Oeynhausen (Germany); Arbeitsgemeinschaft Kardiovaskulaere Nuklearmedizin der Deutschen Gesellschaft fuer Nuklearmedizin (Germany); Bengel, F.M. [Cardiovascular Nuclear Medicine, Johns Hopkins Medical Institutions, Baltimore (United States); Arbeitsgruppe Nuklearkardiologische Diagnostik der Deutschen Gesellschaft fuer Kardiologie (Germany); Zimmermann, R. [Arbeitsgruppe Nuklearkardiologische Diagnostik der Deutschen Gesellschaft fuer Kardiologie (Germany); Medizinische Klinik, Klinikum Pforzheim GmbH, Pforzheim (Germany); Dahl, J. vom [Klinik fuer Kardiologie, Kliniken Maria Hilf GmbH, Moenchengladbach (Germany); Schaefer, W. [Klinik fuer Nuklearmedizin, Universitaetsklinikum Aachen (Germany); Schober, O. [Klinik und Poliklinik fuer Nuklearmedizin, Universitaetsklinikum Muenster UKM (Germany); Schaefers, M. [Arbeitsgemeinschaft Kardiovaskulaere Nuklearmedizin der Deutschen Gesellschaft fuer Nuklearmedizin (Germany); Klinik und Poliklinik fuer Nuklearmedizin, Universitaetsklinikum Muenster UKM (Germany)

    2009-07-01

    Aim: This third survey of the working group Cardiovascular Nuclear Medicine of the German Society of Nuclear Medicine in cooperation with the working group Nuclear Cardiology of the German Cardiac Society was to deliver information on the procedures and in particular on the development of myocardial perfusion scintigraphy (MPS) from 2005 to 2007. Method: 370 questionnaires (222 private practices (PP), 117 hospitals (HO), 31 university hospitals (UH)) were evaluated. Results: MPS of 114,374 patients were reported, 83% were investigated with {sup 99m}Tc-perfusion tracers. 76% [2006=74%] were performed in PP, 15% [2006=17%] in HO and 9% [2006=9%] in UH. Diabetics represented 21% of all MPS patients in 2007. Data of 215 institutions which participated all from 2005 to 2007 showed an increase in MPS of 2.3% (PP +6.8%, HO -4.5%, UH -18.2%). The type of stress was pharmacological in 27% [2006 = 27%]; 67% adenosine (of these 25% with exercise), 31% dipyridamole (of these 55% with exercise), and 2% dobutamine. Gated SPECT was performed in 47% [2006 = 42%] of all rest and in 44% [2006 = 39%] of all stress MPS. 61% [2006 = 83%] of all institutions did not apply perfusion scores. 20% [2006 = 24%] of the institutions reported changes in the use of MPS by competing methods. Conclusion: There is a small increase of MPS between 2005 and 2007 despite competing methods. Gated SPECT has experienced more acceptance, but is still underrepresented. As compared to the European average and general standards of MPS a considerable backlog accounts to pharmacological stress tests, gated SPECT and perfusion scores. (orig.)

  11. Evaluation of heart perfusion in patients with acute myocardial infarction using dynamic contrast-enhanced magnetic resonance imaging

    DEFF Research Database (Denmark)

    Nielsen, Gitte; Hansen, Thomas Fritz; Dirks, Christina G

    2004-01-01

    with acute transmural myocardial infarction were studied using a Turbo-fast low angle shot (FLASH) MRI sequence to monitor the first pass of an extravascular contrast agent (CA), gadolinium diethylene triamine pentaacetic acid (Gd-DTPA). Quantitation of perfusion, expressed as Ki (mL/100 g/minute), in five...... acutely ill patients following acute myocardial infarction. The technique provides information on both the volume and severity of affected myocardial tissue, enabling the power of treatment regimes to be assessed objectively, and this approach should aid individual patient stratification and prognosis...

  12. Evaluation of heart perfusion in patients with acute myocardial infarction using dynamic contrast-enhanced magnetic resonance imaging

    DEFF Research Database (Denmark)

    Nielsen, Gitte; Fritz-Hansen, Thomas; Dirks, Christina G

    2004-01-01

    acutely ill patients following acute myocardial infarction. The technique provides information on both the volume and severity of affected myocardial tissue, enabling the power of treatment regimes to be assessed objectively, and this approach should aid individual patient stratification and prognosis...... with acute transmural myocardial infarction were studied using a Turbo-fast low angle shot (FLASH) MRI sequence to monitor the first pass of an extravascular contrast agent (CA), gadolinium diethylene triamine pentaacetic acid (Gd-DTPA). Quantitation of perfusion, expressed as Ki (mL/100 g/minute), in five...

  13. Diagnostic performance of stress myocardial perfusion imaging for coronary artery disease: A systematic review and meta-analysis

    NARCIS (Netherlands)

    M.C. de Jong (Marcus); T.S.S. Genders (Tessa); R.J.M. van Geuns (Robert Jan); A. Moelker (Adriaan); M.G.M. Hunink (Myriam)

    2012-01-01

    textabstractObjectives To determine and compare the diagnostic performance of stress myocardial perfusion imaging (MPI) for the diagnosis of obstructive coronary artery disease (CAD), using conventional coronary angiography (CCA) as the reference standard. Methods We searched Medline and Embase for

  14. Caffeine intake inverts the effect of adenosine on myocardial perfusion during stress as measured by T1 mapping

    NARCIS (Netherlands)

    Kuijpers, Dirkjan; Prakken, Niek H.; Vliegenthart, Rozemarijn; van Dijkman, Paul R. M.; van der Harst, Pim; Oudkerk, Matthijs

    2016-01-01

    Caffeine intake before adenosine stress myocardial perfusion imaging may cause false negative findings. We hypothesized that the antagonistic effect of caffeine can be measured by T1 relaxation times in rest and adenosine stress cardiac magnetic resonance imaging (CMR), as T1 mapping techniques are

  15. Quantitative Myocardial Perfusion with Dynamic Contrast-Enhanced Imaging in MRI and CT: Theoretical Models and Current Implementation

    Directory of Open Access Journals (Sweden)

    G. J. Pelgrim

    2016-01-01

    Full Text Available Technological advances in magnetic resonance imaging (MRI and computed tomography (CT, including higher spatial and temporal resolution, have made the prospect of performing absolute myocardial perfusion quantification possible, previously only achievable with positron emission tomography (PET. This could facilitate integration of myocardial perfusion biomarkers into the current workup for coronary artery disease (CAD, as MRI and CT systems are more widely available than PET scanners. Cardiac PET scanning remains expensive and is restricted by the requirement of a nearby cyclotron. Clinical evidence is needed to demonstrate that MRI and CT have similar accuracy for myocardial perfusion quantification as PET. However, lack of standardization of acquisition protocols and tracer kinetic model selection complicates comparison between different studies and modalities. The aim of this overview is to provide insight into the different tracer kinetic models for quantitative myocardial perfusion analysis and to address typical implementation issues in MRI and CT. We compare different models based on their theoretical derivations and present the respective consequences for MRI and CT acquisition parameters, highlighting the interplay between tracer kinetic modeling and acquisition settings.

  16. Positron emission tomographic evaluation of regulation of myocardial perfusion in physiological (elite athletes) and pathological (systemic hypertension) left ventricular hypertrophy

    DEFF Research Database (Denmark)

    Kjaer, Andreas; Meyer, Christian; Wachtell, Kristian

    2005-01-01

    Myocardial perfusion (MP) may differ in physiologic and pathologic left ventricular hypertrophy (LVH). We compared MP in LVH in elite athletes and patients with hypertension with healthy, age-matched subjects. We included 12 rowers with LVH, 19 patients with hypertension with LVH, and 2 age...

  17. Development and validation of a patient-tailored dose regime in myocardial perfusion imaging using czt-spect

    NARCIS (Netherlands)

    van Dijk, Joris David; van Dijk, J.D.; Iskandrian, A.; de Jager, P.L.; Mouden, M.; Slump, Cornelis H.; Ottervanger, J.P.; Boer, J.; Oostdijk, A.H.J.; van Dalen, J.A.

    2014-01-01

    Background: Guidelines for SPECT myocardial perfusion imaging (MPI) traditionally recommend a fixed tracer dose. Yet, clinical practice shows degraded image quality in heavier patients. The aim was to optimize and validate the tracer dose and scan time to obtain a constant image quality less

  18. Quantitation in Dextrocardia on myocardial perfusion imaging: how to perform quantitative analysis using Cedars-Sinai software.

    Science.gov (United States)

    Qutbi, Mohsen; Soltanshahi, Mehdi; Ansari, Mojtaba; Hashemi, Hoda; Neshandar Asli, Isa; Shafiei, Babak

    2018-01-01

    Dextrocardia, although a rare cardiac abnormality, carries the same risk for cardiac events as other people. SPECT Myocardial perfusion imaging is a potentially helpful diagnostic tool in patients with dextrocardia. Because of swapping of lateral and septal walls on SPECT slices, although visual analysis is possible, quantitation is substantially limited. Here, we introduce a simple practical method to make quantitative analysis feasible and accurate.

  19. Characteristic findings of exercise ECG test, perfusion SPECT and coronary angiography in patients with exercise induced myocardial stunning

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Byeong Cheol; Seo, Ji Hyoung; Bae, Jin Ho; Jeong, Shin Young; Park, Hun Sik; Lee, Jae Tae; Chae, Shung Chull; Lee, Kyu Bo [School of Medicine, Kyungpook National Univ., Daegu (Korea, Republic of)

    2004-06-01

    Transient wall motion abnormality and contractile dysfunction of the left ventricle (LV) can be observed in patients with coronary artery disease due to post-stress myocardial stunning. To understand clinical characteristics of stress induced LV dysfunction, we have compared the findings of exercise stress test, myocardial perfusion SPECT and coronary angiography between subjects with and without post-stress LV dysfunction. Among subjects who underwent exercise stress test, myocardial perfusion SPECT and coronary angiography within a month of interval, we enrolled 36 patients with post-stress LV ejection fraction (LVEF) was {>=}5% lower than rest (stunning group) and 16 patients with difference of post-stress and rest LVEF was lesser than 1% (non-stunning group) for this study. Treadmill exercise stress gated myocardial perfusion SPECT was performed with dual head SPECT camera using 740 MBq Tc-99m MIBI and coronary angiography was also performed by conventional Judkins method. Stunning group had a significantly higher incidence of hypercholesterolemia than non-stunning group(45.5 vs 7.1%, p=0.01). Stunning group also had higher incidence of diabetes mellitus and lower incidence of hypertension, but these were not statistically significant. Stunning group had larger and more severe perfusion defect in stress perfusion myocardial SPECT than non-stunning group(extent 18.2 vs 9.2%, p=0.029; severity 13.5 vs 6.9, p=0.040). Stunning group also had higher degree of reversibility of perfusion defect, higher incidence of positive exercise stress test and higher incidence of having severe stenosis(80{approx}99%) in coronary angiography than non-stunning group, but these were not statistically significant. In stunning group, all of 4 patients without perfusion defect had significant coronary artery stenosis and had received revascularization treatment. Patients with post-stress LV dysfunction had larger and more severe perfusion defect and severe coronary artery stenosis than

  20. Diagnostic value of transmural perfusion ratio derived from dynamic CT-based myocardial perfusion imaging for the detection of haemodynamically relevant coronary artery stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Coenen, Adriaan; Lubbers, Marisa M.; Dedic, Admir; Chelu, Raluca G.; Geuns, Robert-Jan M. van; Nieman, Koen [Erasmus University Medical Center, Department of Radiology, Rotterdam (Netherlands); Erasmus University Medical Center, Department of Cardiology, Rotterdam (Netherlands); Kurata, Akira; Kono, Atsushi; Dijkshoorn, Marcel L. [Erasmus University Medical Center, Department of Radiology, Rotterdam (Netherlands); Rossi, Alexia [Erasmus University Medical Center, Department of Radiology, Rotterdam (Netherlands); Barts Health NHS Trust, NIHR Cardiovascular Biomedical Research Unit at Barts, William Harvey Research Institute, Barts and The London School of Medicine and Dentistry, Queen Mary University of London and Department of Cardiology, London (United Kingdom)

    2017-06-15

    To investigate the additional value of transmural perfusion ratio (TPR) in dynamic CT myocardial perfusion imaging for detection of haemodynamically significant coronary artery disease compared with fractional flow reserve (FFR). Subjects with suspected or known coronary artery disease were prospectively included and underwent a CT-MPI examination. From the CT-MPI time-point data absolute myocardial blood flow (MBF) values were temporally resolved using a hybrid deconvolution model. An absolute MBF value was measured in the suspected perfusion defect. TPR was defined as the ratio between the subendocardial and subepicardial MBF. TPR and MBF results were compared with invasive FFR using a threshold of 0.80. Forty-three patients and 94 territories were analysed. The area under the receiver operator curve was larger for MBF (0.78) compared with TPR (0.65, P = 0.026). No significant differences were found in diagnostic classification between MBF and TPR with a territory-based accuracy of 77 % (67-86 %) for MBF compared with 70 % (60-81 %) for TPR. Combined MBF and TPR classification did not improve the diagnostic classification. Dynamic CT-MPI-based transmural perfusion ratio predicts haemodynamically significant coronary artery disease. However, diagnostic performance of dynamic CT-MPI-derived TPR is inferior to quantified MBF and has limited incremental value. (orig.)

  1. Pericardial fat and myocardial perfusion in asymptomatic adults from the Multi-Ethnic Study of Atherosclerosis.

    Directory of Open Access Journals (Sweden)

    Tina E Brinkley

    Full Text Available Pericardial fat has adverse effects on the surrounding vasculature. Previous studies suggest that pericardial fat may contribute to myocardial ischemia in symptomatic individuals. However, it is unknown if pericardial fat has similar effects in asymptomatic individuals.We determined the association between pericardial fat and myocardial blood flow (MBF in 214 adults with no prior history of cardiovascular disease from the Minnesota field center of the Multi-Ethnic Study of Atherosclerosis (43% female, 56% Caucasian, 44% Hispanic. Pericardial fat volume was measured by computed tomography. MBF was measured by MRI at rest and during adenosine-induced hyperemia. Myocardial perfusion reserve (PR was calculated as the ratio of hyperemic to resting MBF.Gender-stratified analyses revealed significant differences between men and women including less pericardial fat (71.9±31.3 vs. 105.2±57.5 cm(3, p<0.0001 and higher resting MBF (1.12±0.23 vs. 0.93±0.19 ml/min/g, p<0.0001, hyperemic MBF (3.49±0.76 vs. 2.65±0.72 ml/min/g, p<0.0001, and PR (3.19±0.78 vs. 2.93±0.89, p = 0.03 in women. Correlations between pericardial fat and clinical and hemodynamic variables were stronger in women. In women only (p = 0.01 for gender interaction higher pericardial fat was associated with higher resting MBF (p = 0.008. However, this association was attenuated after accounting for body mass index or rate-pressure product. There were no significant associations between pericardial fat and hyperemic MBF or PR after multivariate adjustment in either gender. In logistic regression analyses there was also no association between impaired coronary vasoreactivity, defined as having a PR <2.5, and pericardial fat in men (OR, 1.18; 95% CI, 0.82-1.70 or women (OR, 1.11; 95% CI, 0.68-1.82.Our data fail to support an independent association between pericardial fat and myocardial perfusion in adults without symptomatic cardiovascular disease. Nevertheless, these

  2. High-resolution myocardial perfusion imaging at 3 T: comparison to 1.5 T in healthy volunteers

    Energy Technology Data Exchange (ETDEWEB)

    Strach, K.; Meyer, C.; Thomas, D.; Naehle, C.P.; Cheng, B.; Schild, H.; Sommer, T. [University of Bonn, Department of Radiology, Bonn (Germany); Schmitz, C. [University of Bonn, Department of Cardiac Surgery, Bonn (Germany); Litt, H. [University of Pennsylvania Medical Center, Department of Radiology, Philadelphia, PA (United States); Bernstein, A. [Harvard School of Public Health, Department of Nutrition, Boston, MA (United States)

    2007-07-15

    The purpose of this study was to evaluate high-resolution (HR) myocardial first-pass perfusion in healthy volunteers at 3 T compared to a typical clinical imaging protocol at 1.5 T, with respect to overall image quality and the presence of subendocardial dark rim artifacts. Myocardial first-pass rest perfusion studies were performed at both field strengths using a T1-weighted saturation-recovery segmented k-space gradient-echo sequence combined with parallel imaging (Gd-DTPA 0.05 mmol/kg). Twenty-six healthy volunteers underwent (1) a HR perfusion scan at 3 T(pixel size 3.78 mm{sup 2}) and (2) a standard perfusion approach at 1.5 T(pixel size 9.86 mm{sup 2}). The contrast enhancement ratio (CER) and overall image quality (4-point grading scale: 4: excellent; 1: non-diagnostic) were assessed, and a semiquantitative analysis of dark rim artifacts was performed for all studies. CER was slightly higher (1.31 {+-} 0.32 vs. 1.14 {+-} 0.34; p<0.01), overall image quality was significantly improved (3.03 {+-} 0.43 vs. 2.37 {+-} 0.39; p<0.01), and the number of dark rim artifacts (139 {+-} 2.09 vs. 243 {+-} 2.33; p<0.01) was significantly reduced for HR perfusion imaging at 3 T compared to the standard approach at 1.5 T. HR myocardial rest perfusion at 3 T is superior to the typical clinical perfusion protocol performed at 1.5 T with respect to the overall image quality and presence of subendocardial dark rim artifacts. (orig.)

  3. Spatial heterogeneity of myocardial perfusion predicts local potassium channel expression and action potential duration.

    Science.gov (United States)

    Stoll, Marion; Quentin, Michael; Molojavyi, Andrej; Thämer, Volker; Decking, Ulrich K M

    2008-02-01

    In the heart, there is not only a transmural gradient of left ventricular perfusion and action potential duration (APD), but also spatial heterogeneity within each myocardial layer, where local blood flow and energy turnover vary more than three-fold between individual regions. We analysed at high spatial resolution whether a corresponding heterogeneity also extends to ion channel gene expression and APD. In the open-chest beagle dog, left ventricular 300 microL samples of very low or high flow were identified by radioactive microspheres and expression levels determined by quantitative PCR. The distribution of epicardial APD was assessed by mapping local activation repolarization intervals (ARIs) and QT interval (QT). ERG, the potassium channel mediating IKr, and KChIP2, the interacting protein modulating Ito, were increased in Low flow (3.3- and 2.5-fold, P channel expression and APD. Whenever this newly recognized intramural dispersion of APD increases, it may contribute to arrhythmogenesis.

  4. Adenosine Stress Induced Left Bundle Branch Block During Technetium-99m Tetrofosmin Myocardial Perfusion Imaging.

    Science.gov (United States)

    Jayanthi, Mohan Roop; Sasikumar, Arun; Gorla, Arun Kumar Reddy; Sood, Ashwani; Bhattacharya, Anish; Mittal, Bhagwant Rai

    2017-01-01

    The occurrence of left bundle branch block (LBBB) in electrocardiogram during exercise testing is a relatively rare finding. The incidence of LBBB during exercise testing ranges from 0.5% to 1.1%. The mechanism of exercise-induced LBBB (EI-LBBB) is poorly understood, but ischemia is a proposed etiology. Stress myocardial perfusion imaging (MPI) can be useful in patients with EI-LBBB to rule out coronary artery disease. Adenosine vasodilator stress is the preferred mode of stress in patients with LBBB for performing stress-MPI. Here we present an interesting case of adenosine-induced LBBB during stress-MPI in a 67-year-old female patient with normal coronary angiography.

  5. The elusive role of myocardial perfusion imaging in stable ischemic heart disease: Is ISCHEMIA the answer?

    Science.gov (United States)

    Xie, Joe X; Winchester, David E; Phillips, Lawrence M; Hachamovitch, Rory; Berman, Daniel S; Blankstein, Ron; Di Carli, Marcelo F; Miller, Todd D; Al-Mallah, Mouaz H; Shaw, Leslee J

    2017-10-01

    The assessment of ischemia through myocardial perfusion imaging (MPI) is widely accepted as an index step in the diagnostic evaluation of stable ischemic heart disease (SIHD). Numerous observational studies have characterized the prognostic significance of ischemia extent and severity. However, the role of ischemia in directing downstream SIHD care including coronary revascularization has remained elusive as reductions in ischemic burden have not translated to improved clinical outcomes in randomized trials. Importantly, selection bias leading to the inclusion of many low risk patients with minimal ischemia have narrowed the generalizability of prior studies along with other limitations. Accordingly, an ongoing randomized controlled trial entitled ISCHEMIA (International Study of Comparative Health Effectiveness with Medical and Invasive Approaches) will compare an invasive coronary revascularization strategy vs a conservative medical therapy approach among stable patients with moderate to severe ischemia. The results of ISCHEMIA may have a substantial impact on the management of SIHD and better define the role of MPI in current SIHD pathways of care.

  6. Technetium myocardial perfusion scanning in prerenal transplant evaluation in the United kingdom.

    LENUS (Irish Health Repository)

    Wong, C F

    2008-06-01

    Because death with a functioning graft remains one of the most important causes of long-term renal transplant failure, cardiac risk stratification and screening for coronary artery disease are essential components of pretransplant assessment. Pretransplant screening for occult coronary artery disease in a subset of these patients may improve outcome. The UK follows the European Best practice guideline 1.5.5 E. Although echocardiography, thallium myocardial perfusion scanning (MPS), dobutamine stress echocardiography, and coronary angiography have been suggested as means of cardiovascular assessment, the best means of assessment remains undetermined. Therefore, we investigated the role of 99m technetium sestamibi myocardial perfusion scanning as an assessment tool for identifying those patients with end-stage renal failure at high risk of cardiovascular death after renal transplantation. Retrospectively, we studied 126 patients that had a MPS as part of their pretransplant assessment. Overall unadjusted survival was 65% at 3 years. Twelve deaths resulted from cardiovascular causes. A reversible defect on MPS was associated with a fatal cardiac event and all-cause mortality. The unadjusted hazard ratio of cardiac event with reversible defect on MPS was 3.1 (95% confidence interval, 1.1 to 18.2) and hazard ratio of death with reversible defect on MPS was 1.92 (95% confidence interval, 1.1 to 4.4). Thus, MPS may be a useful tool in cardiac risk stratification and in selecting patients with a favorable outcome after renal transplantation. Our patients with a reversible defect in particular have increased cardiac mortality. This group may benefit from coronary angiography.

  7. Myocardial Perfusion in Rheumatoid Arthritis Patients: Associations with Traditional Risk Factors and Novel Biomarkers

    Directory of Open Access Journals (Sweden)

    Miguel Bernardes

    2017-01-01

    Full Text Available Introduction. Cardiovascular (CV diseases are a major cause of death in rheumatoid arthritis (RA patients. Novel biomarkers [B-type natriuretic peptide (BNP; osteoprotegerin (OPG/receptor activator of nuclear factor-kappa B ligand (RANKL ratio; and dickkopf-1 (DKK-1] have been used in CV risk assessment. We analysed, in established RA patients, the presence of silent myocardial ischemia and its association with clinical variables, BNP, and bone and atheroma biomarkers. Methods. From a single-center tertiary referral hospital, RA patients asymptomatic for CV disease were submitted to myocardial perfusion scintigraphy (MPS under adenosine stress and biomarkers measurements. Logistic regression was used to estimate crude odds ratios (OR and 95% confidence intervals (CI. Results. In 189 patients, perfusion defects were frequent (25% and associated with BNP ≥ 100 pg/mL (OR = 5.68; 95% CI: 2.038–15.830, fourth log OPG/RANKL ratio quartile (OR = 2.88; 95% CI: 1.091–7.622, and DKK-1 ≥ 133 pmol/L (OR = 2.69; 95% CI: 1.058–6.840. Similar associations were confirmed in those with C-reactive protein > or ≤ 3 mg/L. No relationship was found with the majority of traditional CV factors nor with disease variables. Conclusions. Our results corroborated the hypothesis that MPS could reveal subclinical CV dysfunction, supported the utility of BNP measurements as a screening tool, and put in perspective the potential usefulness of complementary approaches in CV risk assessment in RA patients.

  8. Subendocardial versus transmural ischaemia in myocardial perfusion SPECT--a Monte Carlo study.

    Science.gov (United States)

    Bartosik, Jolanta; El-Ali, Henrik Hussein; Nilsson, Ulf; Dahlström, Jan; Edenbrandt, Lars; Ljungberg, Michael

    2006-11-01

    Myocardial perfusion imaging with single-photon emission computed tomography (SPECT) is useful for the evaluation of patients with known or suspected coronary artery disease. Parameters of interest are the reduction in the blood perfusion (severity) and the lesion volume (extent). The aim of this study was to evaluate these parameters, as calculated by automatic quantification software, for different cases of subendocardial and transmural myocardial lesions. A computer phantom was used to simulate 32 male patients with different defect locations and activity uptakes, which were based on clinical patient studies. The Monte Carlo program SIMIND was used to simulate realistic SPECT projections which were reconstructed to give short-axis images, analysed by the AutoQUANT program using the same procedure as for a real patient. The results showed a disparity between the quantification of transmural and subendocardial lesions with the same lesion activity uptake reduction and this could be confirmed by visual interpretation. Neither the parameters given by the quantification program nor visual interpretation could distinguish between the transmural lesions and the subendocardial lesions with activity uptake reduction twice as high as in the corresponding transmural lesions. Transmural lesions and the corresponding subendocardial lesions with the same activity uptake reduction could be separated by the quantification software for SPECT imaging and visual analysis. The subendocardial lesions with activity uptake reduction twice as high as in the corresponding transmural lesions could not be differentiated neither by the quantification software nor by visual interpretation. Thus these lesions will get the same scoring when analysed by the AutoQUANT program.

  9. Optimization of a protocol for myocardial perfusion scintigraphy by using an anthropomorphic phantom*

    Science.gov (United States)

    Ramos, Susie Medeiros Oliveira; Glavam, Adriana Pereira; Kubo, Tadeu Takao Almodovar; de Sá, Lidia Vasconcellos

    2014-01-01

    Objective To develop a study aiming at optimizing myocardial perfusion imaging. Materials and Methods Imaging of an anthropomorphic thorax phantom with a GE SPECT Ventri gamma camera, with varied activities and acquisition times, in order to evaluate the influence of these parameters on the quality of the reconstructed medical images. The 99mTc-sestamibi radiotracer was utilized, and then the images were clinically evaluated on the basis of data such as summed stress score, and on the technical image quality and perfusion. The software ImageJ was utilized in the data quantification. Results The results demonstrated that for the standard acquisition time utilized in the procedure (15 seconds per angle), the injected activity could be reduced by 33.34%. Additionally, even if the standard scan time is reduced by 53.34% (7 seconds per angle), the standard injected activity could still be reduced by 16.67%, without impairing the image quality and the diagnostic reliability. Conclusion The described method and respective results provide a basis for the development of a clinical trial of patients in an optimized protocol. PMID:25741088

  10. Influence of revascularization on myocardial perfusion, metabolism and function evaluated with I-123-IPPA

    Energy Technology Data Exchange (ETDEWEB)

    Kropp, J.; Krois, M.; Eichhorn, B.; Feske, W.; Likungu, J.; Kirchhoff, P.J.; Luederitz, B.; Biersack, H.J. [Bonn Univ. (Germany); Knapp, F.F. Jr. [Oak Ridge National Lab., TN (United States)

    1993-10-01

    Patients with coronary artery disease (CAD) were investigated with sequential SPECT-scintigraphy after administration of 200 MBq of 15-(p-[I-123]iodophenyl)pentadecanoic acid (IPPA) at peak submaximal exercise. Twenty patients underwent coronary angioplasty (PTCA) from which 14 had control coronary arteriography (CA) and left ventricular cineventriculography (LVCV). Nineteen pts underwent bypass graft surgery (ACB) and stress sonagraphy. Semi-quantification of uptake (Up related to perfusion) and turnover (Tr) was obtained by segmental comparison of oblique slices. About 90% of the reperfused myocardial segments in the PTCA-group and 76% in the ACB-group showed an improvement of uptake after therapy (RUp). Of these, 50% and 66% exhibited increased turnover (RTr) after PTCA or ACB. Pathologic RTr was highly correlated with regional wall motion abnormalities after therapy in both groups. In the ACB-group presence of improvement of RTr was correlated with improved RWM at rest and stress. IPPA-studies show potential to provide information about changes of perfusion and metabolism after reperfusion and IPPA-turnover is a good predictor of the pattern of contractile function.

  11. Static Myocardial Perfusion Imaging using denoised dynamic Rb-82 PET/CT scans

    DEFF Research Database (Denmark)

    Petersen, Maiken N.M.; Hoff, Camilla; Harms, Hans

    . Administered 82Rb dose was 1110 MBq. Denoising using HYPR-LR or Hotelling 3D algorithms was performed as post-processing on the dynamic images series. Static series were created by summing frames from 2.5-5 min. The image data was analysed in QPET (Cedars-Sinai). Relative segmental perfusion (normalized......Introduction: Relative and absolute measures of myocardial perfusion are derived from a single 82Rb PET/CT scan. However, images are inherently noising due to the short half-life of 82Rb. We have previously shown that denoising techniques can be applied to dynamic 82Rb series with excellent...... quantitative accuracy. In this study, we examine static images created by summing late frames of denoised dynamic series. Method: 47 random clinical 82Rb stress and rest scans (27 male, age 68+/- 12 y., BMI 27.9 +/- 5.5 kg/m2) performed on a GE Discovery 690 PET/CT scanner were included in the study...

  12. Optimization of a protocol for myocardial perfusion scintigraphy by using an anthropomorphic phantom

    Energy Technology Data Exchange (ETDEWEB)

    Ramos, Susie Medeiros Oliveira; Sa, Lidia Vasconcellos de, E-mail: susie@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Glavam, Adriana Pereira; Kubo, Tadeu Takao Almodovar [Clinica de Diagnostico Por Imagem (CDPI/DASA), Rio de Janeiro, RJ (Brazil)

    2014-07-15

    Objective: to develop a study aiming at optimizing myocardial perfusion imaging. Materials and Methods: imaging of an anthropomorphic thorax phantom with a GE SPECT Ventri gamma camera, with varied activities and acquisition times, in order to evaluate the influence of these parameters on the quality of the reconstructed medical images. The {sup 99m}Tc-sestamibi radiotracer was utilized, and then the images were clinically evaluated on the basis of data such as summed stress score, and on the technical image quality and perfusion. The software ImageJ was utilized in the data quantification. Results: the results demonstrated that for the standard acquisition time utilized in the procedure (15 seconds per angle), the injected activity could be reduced by 33.34%. Additionally, even if the standard scan time is reduced by 53.34% (7 seconds per angle), the standard injected activity could still be reduced by 16.67%, without impairing the image quality and the diagnostic reliability. Conclusion: the described method and respective results provide a basis for the development of a clinical trial of patients in an optimized protocol. (author)

  13. Myocardial perfusion scintigraphy in Germany. Results of the 2005 query and current status

    Energy Technology Data Exchange (ETDEWEB)

    Lindner, O. [Inst. fuer Radiologie, Nuklearmedizin und Molekulare Bildgebung, Herz- und Diabeteszentrum NRW, Bad Oeynhausen (Germany); Burchert, W. [Inst. fuer Radiologie, Nuklearmedizin und Molekulare Bildgebung, Herz- und Diabeteszentrum NRW, Bad Oeynhausen (Germany); Arbeitsgemeinschaft ' ' Kardiovaskulaere Nuklearmedizin' ' der Deutschen Gesellschaft fuer Nuklearmedizin (Germany); Bengel, F.M. [Cardiovascular Nuclear Medicine, Johns Hopkins Medical Insts., Baltimore (United States); Arbeitsgruppe ' ' Nuklearkardiologische Diagnostik' ' der Deutschen Gesellschaft fuer Kardiologie (Germany); Zimmermann, R. [Arbeitsgruppe ' ' Nuklearkardiologische Diagnostik' ' der Deutschen Gesellschaft fuer Kardiologie (Germany); Medizinische Klinik, Klinikum Pforzheim GmbH (Germany); Dahl, J. vom [Klinik fuer Kardiologie, Kliniken Maria Hilf GmbH, Moenchengladbach (Germany); Schaefer, W.; Buell, U. [Klinik fuer Nuklearmedizin, Universitaetsklinikum Aachen (Germany); Schober, O. [Klinik und Poliklinik fuer Nuklearmedizin, Universitaetsklinikum Muenster (Germany); Schwaiger, M. [Nuklearmedizinische Klinik, Klinikum Rechts der Isar, Muenchen (Germany); Kluge, R. [Klinik und Poliklinik fuer Nuklearmedizin, Univ. Leipzig (Germany); Schaefers, M. [Arbeitsgemeinschaft ' ' Kardiovaskulaere Nuklearmedizin' ' der Deutschen Gesellschaft fuer Nuklearmedizin (Germany); Klinik und Poliklinik fuer Nuklearmedizin, Universitaetsklinikum Muenster (Germany)

    2007-07-01

    The working group Cardiovascular Nuclear Medicine of the German Society of Nuclear Medicine (DGN), in cooperation with the working group Nuclear Cardiology of the German Cardiac Society (DGK), decided to conduct a national survey on myocardial perfusion scintigraphy (MPS). Method: a questionnaire to evaluate MPS for the year 2005 was sent. Results: 346 completed questionnaires had been returned (213 private practices, 99 hospitals and 33 university hospitals). MPS of 112 707 patients were reported with 110 747 stress and 95 878 rest studies. The majority (> 75%) was performed with {sup 99m}Tc-MIBI or tetrofosmin. {sup 201}Tl stress-redistribution was used in 22 637 patients (20%). The types of stress were exercise in 78%, vasodilation with adenosine or dipyridamol in 21% and dobutamine in 1%. 99.97% of all MPS were SPECT studies. Gated SPECT was performed in 36% of the stress and in 32% of the rest studies. An attenuation correction was used in 21%. 29 institutions (8%) performed gated SPECT (stress and rest) and attenuation correction. 47% of all MPS were requested by ambulatory care cardiologists, 17% by internists, 12% by primary care physicians, 21% by hospital departments and 2% by others. Conclusion: in Germany, MPS is predominantly performed with {sup 99m}Tc-perfusion agents. The common type of stress is ergometry. Gated SPECT and attenuation correction do not yet represent standards of MPS practice in Germany, which indicates some potential of optimization. (orig.)

  14. Ventricular dyssynchrony assessed by gated myocardial perfusion SPECT using a geometrical approach: a feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Veen, Berlinda J. van der; Younis, Imad Al [Leiden University Medical Centre, Department of Nuclear Medicine, Leiden (Netherlands); Ajmone-Marsan, Nina; Bax, Jeroen J. [Leiden University Medical Centre, Department of Cardiology, Leiden (Netherlands); Westenberg, Jos J.M.; Roos, Albert de [Leiden University Medical Centre, Department of Radiology, Leiden (Netherlands); Stokkel, Marcel P.M. [Antoni van Leeuwenhoek Hospital, Department of Nuclear Medicine, Netherlands Cancer Institute, Amsterdam (Netherlands)

    2012-03-15

    Left ventricular dyssynchrony may predict response to cardiac resynchronization therapy and may well predict adverse cardiac events. Recently, a geometrical approach for dyssynchrony analysis of myocardial perfusion scintigraphy (MPS) was introduced. In this study the feasibility of this geometrical method to detect dyssynchrony was assessed in a population with a normal MPS and in patients with documented ventricular dyssynchrony. For the normal population 80 patients (40 men and 40 women) with normal perfusion (summed stress score {<=}2 and summed rest score {<=}2) and function (left ventricular ejection fraction 55-80%) on MPS were selected; 24 heart failure patients with proven dyssynchrony on MRI were selected for comparison. All patients underwent a 2-day stress/rest MPS protocol. Perfusion, function and dyssynchrony parameters were obtained by the Corridor4DM software package (Version 6.1). For the normal population time to peak motion was 42.8 {+-} 5.1% RR cycle, SD of time to peak motion was 3.5 {+-} 1.4% RR cycle and bandwidth was 18.2 {+-} 6.0% RR cycle. No significant gender-related differences or differences between rest and post-stress acquisition were found for the dyssynchrony parameters. Discrepancies between the normal and abnormal populations were most profound for the mean wall motion (p value <0.001), SD of time to peak motion (p value <0.001) and bandwidth (p value <0.001). It is feasible to quantify ventricular dyssynchrony in MPS using the geometrical approach as implemented by Corridor4DM. (orig.)

  15. Prognostic Value of Combined Clinical and Myocardial Perfusion Imaging Data Using Machine Learning.

    Science.gov (United States)

    Betancur, Julian; Otaki, Yuka; Motwani, Manish; Fish, Mathews B; Lemley, Mark; Dey, Damini; Gransar, Heidi; Tamarappoo, Balaji; Germano, Guido; Sharir, Tali; Berman, Daniel S; Slomka, Piotr J

    2017-10-16

    This study evaluated the added predictive value of combining clinical information and myocardial perfusion single-photon emission computed tomography (SPECT) imaging (MPI) data using machine learning (ML) to predict major adverse cardiac events (MACE). Traditionally, prognostication by MPI has relied on visual or quantitative analysis of images without objective consideration of the clinical data. ML permits a large number of variables to be considered in combination and at a level of complexity beyond the human clinical reader. A total of 2,619 consecutive patients (48% men; 62 ± 13 years of age) who underwent exercise (38%) or pharmacological stress (62%) with high-speed SPECT MPI were monitored for MACE. Twenty-eight clinical variables, 17 stress test variables, and 25 imaging variables (including total perfusion deficit [TPD]) were recorded. Areas under the receiver-operating characteristic curve (AUC) for MACE prediction were compared among: 1) ML with all available data (ML-combined); 2) ML with only imaging data (ML-imaging); 3) 5-point scale visual diagnosis (physician [MD] diagnosis); and 4) automated quantitative imaging analysis (stress TPD and ischemic TPD). ML involved automated variable selection by information gain ranking, model building with a boosted ensemble algorithm, and 10-fold stratified cross validation. During follow-up (3.2 ± 0.6 years), 239 patients (9.1%) had MACE. MACE prediction was significantly higher for ML-combined than ML-imaging (AUC: 0.81 vs. 0.78; p clinical and imaging data variables was found to have high predictive accuracy for 3-year risk of MACE and was superior to existing visual or automated perfusion assessments. ML could allow integration of clinical and imaging data for personalized MACE risk computations in patients undergoing SPECT MPI. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  16. Quantitative assessment of magnetic resonance derived myocardial perfusion measurements using advanced techniques: microsphere validation in an explanted pig heart system.

    Science.gov (United States)

    Schuster, Andreas; Zarinabad, Niloufar; Ishida, Masaki; Sinclair, Matthew; van den Wijngaard, Jeroen Phm; Morton, Geraint; Hautvast, Gilion Ltf; Bigalke, Boris; van Horssen, Pepijn; Smith, Nicolas; Spaan, Jos Ae; Siebes, Maria; Chiribiri, Amedeo; Nagel, Eike

    2014-10-14

    Cardiovascular Magnetic Resonance (CMR) myocardial perfusion imaging has the potential to evolve into a method allowing full quantification of myocardial blood flow (MBF) in clinical routine. Multiple quantification pathways have been proposed. However at present it remains unclear which algorithm is the most accurate. An isolated perfused, magnetic resonance (MR) compatible pig heart model allows very accurate titration of MBF and in combination with high-resolution assessment of fluorescently-labeled microspheres represents a near optimal platform for validation. We sought to investigate which algorithm is most suited to quantify myocardial perfusion by CMR at 1.5 and 3 Tesla using state of the art CMR perfusion techniques and quantification algorithms. First-pass perfusion CMR was performed in an MR compatible blood perfused pig heart model. We acquired perfusion images at physiological flow ("rest"), reduced flow ("ischaemia") and during adenosine-induced hyperaemia ("hyperaemia") as well as during coronary occlusion. Perfusion CMR was performed at 1.5 Tesla (n = 4 animals) and at 3 Tesla (n = 4 animals). Fluorescently-labeled microspheres and externally controlled coronary blood flow served as reference standards for comparison of different quantification strategies, namely Fermi function deconvolution (Fermi), autoregressive moving average modelling (ARMA), exponential basis deconvolution (Exponential) and B-spline basis deconvolution (B-spline). All CMR derived MBF estimates significantly correlated with microsphere results. The best correlation was achieved with Fermi function deconvolution both at 1.5 Tesla (r = 0.93, p < 0.001) and at 3 Tesla (r = 0.9, p < 0.001). Fermi correlated significantly better with the microspheres than all other methods at 3 Tesla (p < 0.002). B-spline performed worse than Fermi and Exponential at 1.5 Tesla and showed the weakest correlation to microspheres (r = 0.74, p < 0.001). All other comparisons

  17. Comparison of hemodynamic and stress testing variables in patients undergoing regadenoson stress myocardial perfusion imaging to regadenoson with adjunctive low-level exercise myocardial perfusion imaging.

    Science.gov (United States)

    Cabrera, Rafael; Husain, Zehra; Palani, Gurunanthan; Karthikeyan, Aarthee S; Choudhry, Zain; Dhanalakota, Sunita; Peterson, Ed; Ananthasubramaniam, Karthik

    2013-06-01

    Regadenoson (REG), a selective adenosine A2a receptor agonist, is becoming the preferred pharmacologic agent for stress myocardial perfusion imaging (MPI). Hemodynamic and stress variables, immediate safety and use of aminophylline when using REG combined with low-level exercise (REG WALK MPI) compared with REG MPI, have not been well studied and formed the basis of our study. Retrospective evaluation of patients who underwent REG MPI (n = 887) was compared to patients undergoing REG WALK MPI (n = 485) from January to November 2009. Patient demographics, hemodynamic parameters, REG MPI data, side effects, immediate major clinical events, and use of aminophylline were evaluated. Patients in REG WALK MPI group tended to be younger, male and obese compared to patients in REG MPI group. REG WALK MPI patients had higher stress heart rate (103 ± 20.5 vs 84 ± 19 bpm, P = .001), higher heart rate reserve (36.3 ± 19 vs 14.7 ± 15.5 bpm, P < .001), and greater systolic blood pressure rise (4.8 ± 21.3 vs -8.9 ± 19.8 mm Hg, P < .001), compared to REG MPI patients. No major adverse events were reported immediately after REG WALK MPI. There were no differences in drug-related side effects in between the two groups; however, the use of aminophylline was lower in REG WALK MPI Group (5.6% vs 11.4%, P = .001). REG WALK MPI gives more favorable hemodynamic response with lesser use of aminophylline and no increase in adverse events when compared with REG MPI.

  18. {sup 99m}Tc sestamibi myocardial perfusion scintigraphy with the novel use of metamizol for the detection of perfusion reversibility

    Energy Technology Data Exchange (ETDEWEB)

    Erguen, Eser Lay; Caglar, Meltem; Bozkurt, Murat Fani [Hacettepe University, Department of Nuclear Medicine, School of Medicine, Ankara (Turkey); Erguen, Hakan [Ankara University, Department of Pharmacology and Clinical Pharmacology, Faculty of Medicine, Ankara (Turkey)

    2008-08-15

    This study aims to investigate whether induction with metamizol, an analgesic-antipyretic drug having spasmolitic activity, could be used to increase the detectability of ischemic/jeopardized myocardium during MPS (myocardial perfusion scintigraphy). Metamizol-enhanced rest MPS (45 min after administration of 1 g metamizol orally, 740 MBq {sup 99m}Tc sestamibi was injected, MPS was acquired 45 min later) was performed in 21 patients who had perfusion defects on their previous stress-rest {sup 99m}Tc sestamibi MPS. Blood pressure was monitored at 15-min intervals. Stress, rest, metamizol-rest MPS images were interpreted on the model of 20 segments using a visual uptake score (VUS; 0 = normal, 1 = mild, 2 = moderate, 3 = significant decreases, 4 = no uptake). {sup 99m}Tc sestamibi uptake ratios (MIBI-UR; mean counts in the region of the perfusion defect/mean counts in the region of the normal-perfused wall) were obtained on each MPS and compared with each other. Average MIBI-UR in each scintigraphic examination was calculated. MPS were compared with coronary angiography results. VUS and MIBI-UR results showed that metamizol-rest MPS displayed the defect reversibility better than rest MPS. Of the 14 segments with fixed perfusion defects on stress-rest MPS, 8 showed improvement of perfusion after metamizol induction. In 33 segments, lesion reversibility was better delineated on metamizol-rest MPS. Metamizol-induced sestamibi uptake was significantly higher (p < 0.001) than stress/baseline rest examinations as calculated by the MIBI-UR. Blood pressure remained unaltered. Coronary angiography results were in concordance with metamizol induced MPS. Metamizol-enhanced rest MPS increases detectability of ischemic/viable myocardium during MPS. Metamizol should be discontinued like nitrates before stress MPS since it may mask the visualization of ischemic perfusion defects. (orig.)

  19. Is myocardial stress perfusion MR-imaging suitable to predict the long term clinical outcome after revascularization?

    Energy Technology Data Exchange (ETDEWEB)

    Klumpp, B., E-mail: bernhard.klumpp@med.uni-tuebingen.de [Eberhard Karls University Tuebingen, Department for Diagnostic and Interventional Radiology, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany); Seeger, A., E-mail: achim.seeger@med.uni-tuebingen.de [Eberhard Karls University Tuebingen, Department for Diagnostic and Interventional Radiology, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany); Bretschneider, C., E-mail: christiane.bretschneider@med.uni-tuebingen.de [Eberhard Karls University Tuebingen, Department for Diagnostic and Interventional Radiology, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany); Mangold, S., E-mail: stephanie.mangold@med.uni-tuebingen.de [Eberhard Karls University Tuebingen, Department for Diagnostic and Interventional Radiology, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany); Krumm, P., E-mail: patrick.krumm@med.uni-tuebingen.de [Eberhard Karls University Tuebingen, Department for Diagnostic and Interventional Radiology, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany); Miller, S., E-mail: Miller@radiologie-tue.de [Eberhard Karls University Tuebingen, Department for Diagnostic and Interventional Radiology, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany); Claussen, C.D., E-mail: claus.claussen@med.uni-tuebingen.de [Eberhard Karls University Tuebingen, Department for Diagnostic and Interventional Radiology, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany); Gawaz, M.P., E-mail: meinrad.gawaz@med.uni-tuebingen.de [Eberhard Karls University Tuebingen, Department for Cardiology, Ottfried-Mueller-Str. 10, 72076 Tuebingen (Germany); May, A.E., E-mail: andreas.may@med.uni-tuebingen.de [Eberhard Karls University Tuebingen, Department for Cardiology, Ottfried-Mueller-Str. 10, 72076 Tuebingen (Germany); Kramer, U., E-mail: ulrich.kramer@med.uni-tuebingen.de [Eberhard Karls University Tuebingen, Department for Diagnostic and Interventional Radiology, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany)

    2013-10-01

    Introduction: Aim of our study was to evaluate, whether myocardial ischemia or myocardial infarction (MI) depicted by myocardial stress perfusion MR imaging (SP CMR) can predict the clinical outcome in patients with coronary artery disease (CAD). Materials and method: 220 patients were included. Myocardial perfusion was assessed at stress and at rest, using a 2D saturation recovery gradient echo sequence (SR GRE) and myocardial viability by late gadolinium enhancement magnetic resonance images (LGE CMR). MR-images were assessed in regard of presence and extent of MI and ischemia. Patients were monitored for major adverse cardiac events (MACE) (monitoring period: 5–7 years). MACE were correlated with the initial results of SP CMR. Results: Ischemia was found in 143 patients, MI in 107 patients. Number of MACE was in patients with normal SP CMR 0 (51 patients), with ischemia 21 (62 patients), with MI 14 (26 patients), with ischemia and MI 52 (81 patients). In all patients with severe MACE (MI, death) and in 63 of those with recurring symptoms LGE CMR revealed MI at baseline. Conclusion: Negative SP CMR indicates low risk for MACE. In patients with stress induced ischemia, MACE might occur even after myocardial revascularization. The presence of MI proved by LGE CMR is associated with a significantly increased risk for MACE.

  20. [Regadenoson as a new stress agent in myocardial perfusion imaging. Initial experience in The Netherlands].

    Science.gov (United States)

    Jager, P L; Buiting, M; Mouden, M; Oostdijk, A H J; Timmer, J; Knollema, S

    2014-01-01

    Regadenoson is a recently approved selective adenosine-2A receptor agonist to induce pharmacological stress in myocardial perfusion imaging (MPI) procedures using a single bolus injection. We included 123 patients referred for MPI because of suspected coronary arterial disease (CAD). Of these, 66 patients underwent a regadenoson stress test and 57 patients underwent an adenosine stress test preceding standard myocardial SPECT imaging. Technicians, physicians and patients were asked to report their experience using questionnaires. As compared to adenosine, regadenoson did not produce any atrio-ventricular block (0 vs. 10% with adenosine), but did produce minor tachycardia and minimal blood pressure changes while all other side effects were milder and shorter. There were fewer patients with severe complaints after taking regadenoson than adenosine (17% vs. 32%, respectively, p<0.01). The most frequent complaint reported was dyspnea, followed by flushing and chest pain. However, when they did occur, they usually disappeared rapidly. The overall symptom score, including severity and duration of side effects, was significantly lower after regadenoson than after adenosine (6.7±6.3 vs. 10.0±7.9, respectively; p<0.01.) SPECT imaging results were similar. The regadenoson procedure was faster and more practical. Regadenoson, the new selective adenosine-2A receptor agonist, is a stress agent for MPI with a patient- and department friendly profile. Copyright © 2014 Elsevier España, S.L.U. and SEMNIM. All rights reserved.

  1. EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT: 2015 revision

    Energy Technology Data Exchange (ETDEWEB)

    Verberne, Hein J.; Eck-Smit, Berthe L.F. van; Wit, Tim C. de [University of Amsterdam, Department of Nuclear Medicine, F2-238, Academic Medical Center, Amsterdam (Netherlands); Acampa, Wanda [National Council of Research, Institute of Biostructures and Bioimaging, Naples (Italy); Anagnostopoulos, Constantinos [Academy of Athens, Center for Experimental Surgery, Clinical and Translational Research, Biomedical Research Foundation, Athens (Greece); Ballinger, Jim [Guy' s Hospital - Guy' s and St Thomas' Trust Foundation, Department of Nuclear Medicine, London (United Kingdom); Bengel, Frank [Hannover Medical School, Department of Nuclear Medicine, Hannover (Germany); Bondt, Pieter De [OLV Hospital, Department of Nuclear Medicine, Aalst (Belgium); Buechel, Ronny R.; Kaufmann, Philip A. [University Hospital Zurich, Cardiac Imaging, Zurich (Switzerland); Cuocolo, Alberto [University Federico II, Department of Advanced Biomedical Sciences, Naples (Italy); Flotats, Albert [Universitat Autonoma de Barcelona, Nuclear Medicine Department, Hospital de la Santa Creu i Sant Pau, Barcelona (Spain); Hacker, Marcus [Medical University of Vienna, Division of Nuclear Medicine, Department of Biomedical Imaging and Image-Guided Therapy, Vienna (Austria); Hindorf, Cecilia [Skaane University Hospital, Department of Radiation Physics, Lund (Sweden); Lindner, Oliver [University Hospital of the Ruhr-University Bochum, Heart and Diabetes Center North Rhine-Westphalia, Institute for Radiology, Nuclear Medicine and Molecular Imaging, Bad Oeynhausen (Germany); Ljungberg, Michael [Lund University, Department of Medical Radiation Physics, Lund (Sweden); Lonsdale, Markus [Bispebjerg Hospital, Department of Clinical Physiology and Nuclear Medicine, Copenhagen (Denmark); Manrique, Alain [Caen University Hospital, Department of Nuclear Medicine, Service Commun Investigations chez l' Homme, GIP Cyceron, Caen (France); Minarik, David [Skaane University Hospital, Radiation Physics, Malmoe (Sweden); Scholte, Arthur J.H.A. [Leiden University Medical Center, Department of Cardiology, Leiden (Netherlands); Slart, Riemer H.J.A. [University of Groningen, University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); Traegaardh, Elin [Skaane University Hospital and Lund University, Clinical Physiology and Nuclear Medicine, Malmoe (Sweden); Hesse, Birger [University Hospital of Copenhagen, Department of Clinical Physiology and Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark)

    2015-11-15

    Since the publication of the European Association of Nuclear Medicine (EANM) procedural guidelines for radionuclide myocardial perfusion imaging (MPI) in 2005, many small and some larger steps of progress have been made, improving MPI procedures. In this paper, the major changes from the updated 2015 procedural guidelines are highlighted, focusing on the important changes related to new instrumentation with improved image information and the possibility to reduce radiation exposure, which is further discussed in relation to the recent developments of new International Commission on Radiological Protection (ICRP) models. Introduction of the selective coronary vasodilator regadenoson and the use of coronary CT-contrast agents for hybrid imaging with SPECT/CT angiography are other important areas for nuclear cardiology that were not included in the previous guidelines. A large number of minor changes have been described in more detail in the fully revised version available at the EANM home page: http://eanm.org/ publications/guidelines/2015{sub 0}7{sub E}ANM{sub F}INAL myocardial{sub p}erfusion{sub g}uideline.pdf. (orig.)

  2. High-resolution myocardial stress perfusion at 3 T in patients with suspected coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, Carsten; Strach, Katharina; Thomas, Daniel; Naehle, Claas P.; Schwenger, Ulrich; Schild, Hans H.; Sommer, Torsten [University of Bonn, Department of Radiology, Bonn (Germany); Litt, Harold [University of Pennsylvania Medical Center, Department of Radiology, Philadelphia (United States); Tiemann, Klaus [University of Bonn, Department of Cardiology, Bonn (United States)

    2008-02-15

    To implement a high-resolution first-pass myocardial perfusion imaging protocol (HRPI) at 3 T, and to evaluate the feasibility, image quality and accuracy of this approach prospectively in patients with suspected CAD. We hypothesized that utilizing the gain in SNR at 3 T to increase spatial resolution would reduce partial volume effects and subendocardial dark rim artifacts in comparison to 1.5 T. HRPI studies were performed on 60 patients using a segmented k-space gradient echo sequence (in plane resolution 1.97 x 1.94 mm{sup 2}). Semiquantitative assessment of dark rim artifacts was performed for the stress studies on a slice-by-slice basis. Qualitative visual analysis was compared to quantitative coronary angiography (QCA) results; hemodynamically significant CAD was defined as stenosis {>=}70% at QCA. Dark rim artifacts appeared in 108 of 180 slices (average extent 1.3 {+-} 1.2 mm representing 11.8 {+-} 10.8% of the transmural myocardial thickness). Sensitivity, specifity, and test accuracy for the detection of significant CAD were 89%,79%, and 85%. HRPI studies at 3 T are feasible in a clinical setting, providing good image quality and high accuracy for detection of significant CAD. The presence of dark rim artifacts does not appear to represent a diagnostic problem when using a HRPI approach. (orig.)

  3. Correlation of angina pectoris and perfusion decrease by collateral circulation in single-vessel coronary chronic total occlusion using myocardial perfusion single-photon emssion computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Sang Geon; Park, Ki Seong; Kang, Sae Ryung [Chonnam National University Hospital, Gwangju (Korea, Republic of); and others

    2016-03-15

    To evaluate the perfusion decrease in donor myocardium by collateral circulation and its correlation with angina pectoris in patients with chronic total occlusion (CTO) using myocardial perfusion single-photon emission computed tomography (MPS). Thirty-six patients with single-vessel CTO without any other stenosis were included. All patients underwent MPS and coronary angiography (CAG) within 2 months. Total 72 donor arteries were evaluated for the grades of collaterals to the CTO artery using the Rentrop grading system on CAG. Perfusion defects and perfusion scores in donor and CTO territories were analyzed on MPS. Myocardial perfusion of donor and CTO territories were evaluated according to the presence of angina pectoris and the grades of collateral circulation. When the CTO territory was ischemic, symptomatic patients showed higher summed difference scores in the CTO territory compared to asymptomatic patients (3.5 ± 2.4 vs. 1.5 ± 0.8 for symptomatic and asymptomatic groups respectively; p = 0.034). However, when the CTO territory was nonischemic, symptomatic patients showed higher summed stress scores (SSS, 4.3 ± 2.9 vs. 1.6 ± 1.2; p = 0.032) and summed rest scores (SRS, 4.2 ± 2.5 vs. 1.5 ± 1.1; p = 0.003) in the donor territories. On the per-vessel analysis, perfusion defects in donor territories were more frequent (0 % vs. 53 % vs. 86 % for Rentrop 0, Rentrop 1–2 and Rentrop 3, respectively; p < 0.001) and showed higher SSS (0.0 ± 0.0, 1.3 ± 1.6 and 2.1 ± 1.1 for Rentrop 0, Rentrop 1–2 and Rentrop 3, respectively; p = 0.001) and SRS (0.0 ± 0.0, 1.0 ± 1.4 and 1.7 ± 1.2; p = 0.003) at higher Rentrop grades, but their patterns were variable. Angina pectoris was related to either ischemia of the myocardium beyond CTO or a perfusion decrease in the donor myocardium. The perfusion decrease in donor myocardium positively correlated with the collateral grades.

  4. Dobutamine stress myocardial perfusion imaging: 8-year outcomes in patients with diabetes mellitus.

    Science.gov (United States)

    Boiten, Hendrik J; van Domburg, Ron T; Valkema, Roelf; Zijlstra, Felix; Schinkel, Arend F L

    2016-08-01

    Many studies have examined the prognostic value of myocardial perfusion imaging (MPI) using single-photon emission computed tomography (SPECT) for the prediction of short- to medium-term outcomes. However, the long-term prognostic value of MPI in patients with diabetes mellitus remains unclear. Therefore, this study assessed the long-term prognostic value of MPI in a high-risk cohort of patients with diabetes mellitus. A high-risk cohort of 207 patients with diabetes mellitus who were unable to undergo exercise testing underwent dobutamine stress MPI. Follow-up was successful in 206 patients; 12 patients were excluded due to early revascularization. The current data are based on the remaining 194 patients. Follow-up end points were all-cause mortality, cardiac mortality, and nonfatal myocardial infarction. The Kaplan-Meier survival curves were constructed, and univariable and multivariable analyses were performed to identify predictors of long-term outcome. During a mean follow-up of 8.1 ± 5.9 years, 134 (69%) patients died of which 68 (35%) died due to cardiac causes. Nonfatal myocardial infarction occurred in 24 patients (12%), and late (>60 days) coronary revascularization was performed in 61 (13%) patients. Survival analysis showed that MPI provided optimal risk stratification up to 4 years after testing. After that period, the outcome was comparable in patients with normal and abnormal MPI. Multivariable analyses showed that MPI provided incremental prognostic value up to 4 years after testing. In high-risk patients with diabetes mellitus, dobutamine MPI provides incremental prognostic information in addition to clinical data for a 4-year period after testing. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  5. Attenuation correction in myocardial perfusion SPECT/CT: effects of misregistration and value of reregistration.

    Science.gov (United States)

    Goetze, Sibyll; Brown, Tracy L; Lavely, William C; Zhang, Zhe; Bengel, Frank M

    2007-07-01

    The accuracy of myocardial perfusion SPECT improves with attenuation correction. Algorithms for attenuation correction in hybrid SPECT/CT systems have the potential for misregistration of emission and transmission scans because CT and SPECT are obtained sequentially. Misregistration will influence regional tracer distribution and may reduce diagnostic accuracy. This study focused on the role of misregistration in cardiac SPECT/CT and the performance of a software-based approach for reregistration. We included 105 consecutive patients who underwent clinical myocardial perfusion imaging on a SPECT/CT system. Images were quantitatively assessed for misregistration using fusion software. Results were recorded in millimeters in the x-, y-, and z-axes. Regional tracer uptake in 6 segments (anterior, septal, inferior, lateral, anteroapical, and inferoapical) for noncorrected and attenuation-corrected images before and after reregistration was obtained from polar maps. To determine the relative influence of misregistration, we correlated individual differences between noncorrected and attenuation-corrected images, as well as between attenuation-corrected images before and after reregistration, with the degree of misregistration in a multivariate analysis including additional clinical variables such as sex and body weight. The difference in regional radiotracer uptake was significant between noncorrected and attenuation-corrected images in all 6 segments and was most pronounced in the inferior wall. On multivariate analysis, misregistration contributed significantly to changes in radiotracer distribution in the anterior (P = 0.038), septal (P = 0.011), and inferior (P = 0.006) segments. The mean misregistration was 8.6 +/- 3.8 mm (1.25 +/- 0.55 pixel). Misregistration of one or more pixels was observed in 64% of studies. Reregistration of misalignment significantly affected regional radiotracer distribution in the segments shown to be influenced by misregistration

  6. Dietary red palm oil supplementation reduces myocardial infarct size in an isolated perfused rat heart model

    Directory of Open Access Journals (Sweden)

    Esterhuyse Adriaan J

    2010-06-01

    Full Text Available Abstract Background and Aims Recent studies have shown that dietary red palm oil (RPO supplementation improves functional recovery following ischaemia/reperfusion in isolated hearts. The main aim of this study was to investigate the effects of dietary RPO supplementation on myocardial infarct size after ischaemia/reperfusion injury. The effects of dietary RPO supplementation on matrix metalloproteinase-2 (MMP2 activation and PKB/Akt phosphorylation were also investigated. Materials and methods Male Wistar rats were divided into three groups and fed a standard rat chow diet (SRC, a SRC supplemented with RPO, or a SRC supplemented with sunflower oil (SFO, for a five week period, respectively. After the feeding period, hearts were excised and perfused on a Langendorff perfusion apparatus. Hearts were subjected to thirty minutes of normothermic global ischaemia and two hours of reperfusion. Infarct size was determined by triphenyltetrazolium chloride staining. Coronary effluent was collected for the first ten minutes of reperfusion in order to measure MMP2 activity by gelatin zymography. Results Dietary RPO-supplementation decreased myocardial infarct size significantly when compared to the SRC-group and the SFO-supplemented group (9.1 ± 1.0% versus 30.2 ± 3.9% and 27.1 ± 2.4% respectively. Both dietary RPO- and SFO-supplementation were able to decrease MMP2 activity when compared to the SRC fed group. PKB/Akt phosphorylation (Thr 308 was found to be significantly higher in the dietary RPO supplemented group when compared to the SFO supplemented group at 10 minutes into reperfusion. There was, however, no significant changes observed in ERK phosphorylation. Conclusions Dietary RPO-supplementation was found to be more effective than SFO-supplementation in reducing myocardial infarct size after ischaemia/reperfusion injury. Both dietary RPO and SFO were able to reduce MMP2 activity, which suggests that MMP2 activity does not play a major role in

  7. Effect of intracoronary injection of tirofiban combined with anisodamine on myocardial perfusion in patients with STEMI after PCI

    Directory of Open Access Journals (Sweden)

    Xiao-Gang Zhu

    2016-10-01

    Full Text Available Objective: To analyze the effect of intracoronary injection of tirofiban combined with anisodamine on myocardial perfusion in patients with STEMI after PCI. Methods: A total of 78 patients with acute ST segment elevation myocardial infarction (STEMI who received PCI therapy in our hospital were randomly divided into control group and observation group, control group accepted routine PCI treatment, observation group received intracoronary injection of tirofiban and anisodamine in PCI, and myocardial perfusion of two groups was compared. Results: QRS duration values of observation group the instant after PCI and 4h after PCI were less than those of control group (P<0.05; 99mTc-MIBI and 18F-FDG intake of observation group after PCI were more than those of control group (P<0.05; serum MCP-1, sFas, Copeptin, OPN and vWF levels of observation group 4 h after PCI were lower than those of control group (P<0.05. Conclusions: Intracoronary injection of tirofiban combined with anisodamine can optimize myocardial perfusion in patients with STEMI after PCI, and has positive clinical significance.

  8. An empirical method for reducing variability and complexity of myocardial perfusion quantification by dual bolus cardiac MRI.

    Science.gov (United States)

    Chatterjee, Neil; Benefield, Brandon C; Harris, Kathleen R; Fluckiger, Jacob U; Carroll, Timothy; Lee, Daniel C

    2017-06-01

    Myocardial perfusion can be quantified using the "dual bolus" technique, which uses two separate contrast boluses to avoid signal nonlinearity in the blood pool. This technique relies on knowing the precise ratio of contrast concentrations between the two boluses. In this study, we investigated the variability found in these ratios, as well as the error it introduces, and developed a method for correction. Five dogs received dual bolus myocardial perfusion MRI scans. Perfusion was calculated separately using assumed contrast dilution ratios and empirically determined contrast ratios. Perfusion was compared with reference standard fluorescent microspheres. The same technique was then applied to a cohort of six patients with no significant coronary artery stenosis by cardiac catheterization. Assumed contrast dilution ratios were 10:1 for all animal and patient scans. Empirically derived contrast ratios were significantly different for animal (8.51:1 ± 1.53:1, P empirically derived ratios for animal scans improved correlation with microspheres from 0.84 to 0.90 (P Empirically deriving the correct ratio is feasible and improves the accuracy of quantitative perfusion measurements. Magn Reson Med 77:2347-2355, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  9. MRI-assisted dual motion correction for myocardial perfusion defect detection in PET imaging.

    Science.gov (United States)

    Wang, Xinhui; Rahmim, Arman; Tang, Jing

    2017-09-01

    Myocardial perfusion (MP) PET imaging is a powerful tool in risk assessment and stratification of patients with coronary artery disease. Involuntary organ motion degrades cardiac PET image resolution, while respiratory and/or cardiac gating to freeze the motion leads to noisier reconstructed images due to reduced counts in the gated frames. In this work, we propose an MRI-assisted dual motion correction method to compensate for respiratory and cardiac motion in MP PET data and study the impact of dual motion correction on MP defect detection using systematically designed experiments. The proposed dual motion correction method addresses the respiratory motion before correcting the cardiac motion among the respiratory motion corrected cardiac gates. The respiratory motion is estimated from the respiratory-gated only PET images and compensated within a 4D motion-incorporated image reconstruction algorithm. The cardiac motion is then corrected using the motion vector fields estimated from the corresponding cardiac-gated MR images. To evaluate the proposed method, we performed experiments using the standard XCAT phantom and two individual-specific volunteer XCAT phantoms. For each of the three phantoms, we simulated four dual-gated Rb-82 MP PET imaging datasets, one with normal perfusion and the other three with 50% nontransmural, 75% nontransmural, and transmural regionally reduced perfusion. The corresponding cardiac-gated MR images were simulated by the SIMRI simulator, with the sequence specified to be 3D T1-weighted as used in a protocol of a clinical PET/MRI scanner. We quantitatively evaluated the reconstructed images with no motion correction, only respiratory motion correction and dual motion correction, in terms of the myocardium to blood pool contrast and the trade-off between the noise and the normal to defect contrast. Using the channelized Hotelling observer, we performed receiver operating characteristic analysis for the task of detecting perfusion

  10. Myocardial perfusion magnetic resonance imaging using sliding-window conjugate-gradient HYPR methods in canine with stenotic coronary arteries.

    Science.gov (United States)

    Ge, Lan; Kino, Aya; Lee, Daniel; Dharmakumar, Rohan; Carr, James C; Li, Debiao

    2010-01-01

    First-pass perfusion magnetic resonance imaging (MRI) is a promising technique for detecting ischemic heart disease. However, the diagnostic value of the method is limited by the low spatial coverage, resolution, signal-to-noise ratio (SNR), and cardiac motion-related image artifacts. A combination of sliding window and conjugate-gradient HighlY constrained back-PRojection reconstruction (SW-CG-HYPR) method has been proposed in healthy volunteer studies to reduce the acquisition window for each slice while maintaining the temporal resolution of 1 frame per heartbeat in myocardial perfusion MRI. This method allows for improved spatial coverage, resolution, and SNR. In this study, we use a controlled animal model to test whether the myocardial territory supplied by a stenotic coronary artery can be detected accurately by SW-CG-HYPR perfusion method under pharmacological stress. Results from 6 mongrel dogs (15-25 kg) studies demonstrate the feasibility of SW-CG-HYPR to detect regional perfusion defects. Using this method, the acquisition time per cardiac cycle was reduced by a factor of 4, and the spatial coverage was increased from 2 to 3 slices to 6 slices as compared with the conventional techniques including both turbo-Fast Low Angle Short (FLASH) and echoplanar imaging (EPI). The SNR of the healthy myocardium at peak enhancement with SW-CG-HYPR (12.68 ± 2.46) is significantly higher (P < 0.01) than the turbo-FLASH (8.65 ± 1.93) and EPI (5.48 ± 1.24). The spatial resolution of SW-CG-HYPR images is 1.2 × 1.2 × 8.0 mm, which is better than the turbo-FLASH (1.8 × 1.8 × 8.0 mm) and EPI (2.0 × 1.8 × 8.0 mm). Sliding-window CG-HYPR is a promising technique for myocardial perfusion MRI. This technique provides higher image quality with respect to significantly improved SNR and spatial resolution of the myocardial perfusion images, which might improve myocardial perfusion imaging in a clinical setting.

  11. Myocardial perfusion scintigraphy in Germany in 2009: utilization and state of the practice

    Energy Technology Data Exchange (ETDEWEB)

    Lindner, Oliver; Burchert, Wolfgang [University Hospital of the Ruhr University Bochum, Institute of Radiology, Nuclear Medicine and Molecular Imaging, Heart and Diabetes Centre North Rhine-Westphalia, Bad Oeynhausen (Germany); Bengel, Frank M. [Hanover University School of Medicine, Department of Nuclear Medicine, Hannover (Germany); Zimmermann, Rainer [Klinikum Pforzheim GmbH, Cardiology Department, Pforzheim (Germany); Dahl, Juergen vom [Kliniken Maria Hilf GmbH, Cardiology Department, Moenchengladbach (Germany); Schaefers, Michael [Westfaelische Wilhelms Universitaet Muenster, European Institute of Molecular Imaging, Muenster (Germany)

    2011-08-15

    Since 2006, the working group Cardiovascular Nuclear Medicine of the German Society of Nuclear Medicine, in cooperation with the working group Nuclear Cardiology of the German Cardiac Society, has been surveying the utilization and technical realization of myocardial perfusion scintigraphy (MPS) in Germany. This paper presents the results of the reporting year 2009. A total of 291 centres participated in the inquiry, including 179 private practices (PP), 86 hospitals (HO) and 26 university hospitals (UH). MPS of 98,103 patients were reported. The MPS numbers per million population (pmp) were estimated at 2,360; 76% of the MPS were performed in PP, 17% in HO and 7% in UH. The ratio of MPS to coronary angiography to revascularization was 0.5 to 2.3 to 1. Data from 134 centres which participated in the surveys from 2005 to 2009 showed a decrease in MPS utilization of 2.2%. Nearly half of the MPS were requested by ambulatory care cardiologists. Of all MPS studies, 89% were conducted with {sup 99m}Tc perfusion tracers. Ergometry was the preferred stress test (69%). Adenosine was used in 16%, adenosine + exercise in 7%, dipyridamole in 3%, dipyridamole + exercise in 5% and dobutamine in <1%. Gated single proton emission computed tomography (SPECT) acquisition was performed in 56% of all rest MPS and in 56% of all stress MPS. Both rest and stress MPS were ECG gated in 41%. Only 33% of the centres always performed a quantification of the perfusion studies, whereas 51% did not apply any quantification; 4% of the MPS studies were corrected for attenuation, and 17 centres used transmission sources of 12 CT-based systems. A scan activity of 2,380 MPS pmp is in the upper third of the European range. The ratios to coronary angiography and to revascularization suggest that angiography dominates diagnosis and management of coronary artery disease (CAD). The clinical and technical realizations reveal that the predominant goals of further trainings to optimize MPS are in the field

  12. Quantification of myocardial perfusion using cardiac magnetic resonance imaging correlates significantly to rubidium-82 positron emission tomography in patients with severe coronary artery disease

    DEFF Research Database (Denmark)

    Qayyum, Abbas A; Hasbak, Philip; Larsson, Henrik B W

    2014-01-01

    INTRODUCTION: Aim was to compare absolute myocardial perfusion using cardiac magnetic resonance imaging (CMRI) based on Tikhonov's procedure of deconvolution and rubidium-82 positron emission tomography (Rb-82 PET). MATERIALS AND METHODS: Fourteen patients with coronary artery stenosis underwent ...

  13. High spatial resolution myocardial perfusion imaging during high dose dobutamine/atropine stress magnetic resonance using k-t SENSE.

    Science.gov (United States)

    Gebker, R; Jahnke, C; Manka, R; Frick, M; Hucko, T; Kozerke, S; Schnackenburg, B; Fleck, E; Paetsch, I

    2012-07-26

    To prospectively evaluate the feasibility and diagnostic accuracy of high spatial resolution myocardial perfusion imaging during high dose dobutamine/atropine stress magnetic resonance (DSMR) for the detection of coronary artery disease (CAD). DSMR-wall motion was combined with perfusion imaging (DSMR-perfusion) in 78 patients prior to clinically indicated invasive coronary angiography. For DSMR-perfusion an in-plane spatial resolution of 1.5 × 1.5mm(2) was attained by using 8 × k-space and time sensitivity encoding (k-t SENSE). Image quality and extent of artifacts during perfusion imaging were evaluated. Wall motion and perfusion data were interpreted sequentially. Significant CAD (stenosis ≥ 70%) was present in 52 patients and involved 86 coronary territories. One patient did not reach target heart rate despite maximum infusion of dobutamine/atropine. Two studies (3%) were non-diagnostic due k-t SENSE related artifacts resulting from insufficient breathhold capability. Overall image quality was good. Dark-rim artifacts were limited to the endocardial border at a mean width of 1.8mm. The addition of DSMR-perfusion to DSMR-wall motion data improved sensitivity for the detection of CAD (92% vs. 81%, P=0.03) and accurate determination of disease extent (85% vs. 66% of territories, Pspatial resolution DSMR-perfusion imaging at maximum stress level was feasible, improved sensitivity over DSMR-wall motion for the detection of CAD and allowed an accurate determination of disease extent. Specificity of DSMR-perfusion with k-t SENSE improved compared to prior studies using lower spatial resolution. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  14. Incremental value of myocardial perfusion over coronary angiography by spectral computed tomography in patients with intermediate to high likelihood of coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Carrascosa, Patricia M., E-mail: investigacion@diagnosticomaipu.com.ar; Deviggiano, Alejandro; Capunay, Carlos; Campisi, Roxana; López Munain, Marina de; Vallejos, Javier; Tajer, Carlos; Rodriguez-Granillo, Gaston A.

    2015-04-15

    Highlights: •We evaluated myocardial perfusion by dual energy computed tomography (DECT). •We included patients with intermediate to high likelihood of coronary artery disease. •Stress myocardial perfusion by DECT had a reliable accuracy for the detection of ischemia. •Stress myocardial perfusion with DECT showed an incremental value over anatomical evaluation. •DECT imaging was associated to a significant reduction in radiation dose compared to SPECT. -- Abstract: Purpose: We sought to explore the diagnostic performance of dual energy computed tomography (DECT) for the evaluation of myocardial perfusion in patients with intermediate to high likelihood of coronary artery disease (CAD). Materials and methods: Consecutive patients with known or suspected CAD referred for myocardial perfusion imaging by single-photon emission computed tomography (SPECT) constituted the study population and were scanned using a DECT scanner equipped with gemstone detectors for spectral imaging, and a SPECT. The same pharmacological stress was used for both scans. Results: Twenty-five patients were prospectively included in the study protocol. The mean age was 63.4 ± 10.6 years. The total mean effective radiation dose was 7.5 ± 1.2 mSv with DECT and 8.2 ± 1.7 mSv with SPECT (p = 0.007). A total of 425 left ventricular segments were evaluated by DECT, showing a reliable accuracy for the detection of reversible perfusion defects [area under ROC curve (AUC) 0.84 (0.80–0.87)]. Furthermore, adding stress myocardial perfusion provided a significant incremental value over anatomical evaluation alone by computed tomography coronary angiography [AUC 0.70 (0.65–0.74), p = 0.003]. Conclusions: In this pilot investigation, stress myocardial perfusion by DECT demonstrated a significant incremental value over anatomical evaluation alone by CTCA for the detection of reversible perfusion defects.

  15. Endocardial-epicardial distribution of myocardial perfusion reserve assessed by multidetector computed tomography in symptomatic patients without significant coronary artery disease

    DEFF Research Database (Denmark)

    Kühl, Jørgen Tobias; George, Richard T; Mehra, Vishal C

    2016-01-01

    (MPR) in humans. We aimed to test the hypothesis that MPR in all myocardial layers is determined by age, gender, and cardiovascular risk profile in patients with ischaemic symptoms or equivalent but without obstructive coronary artery disease (CAD). METHODS AND RESULTS: A total of 149 patients enrolled...... in endocardial-epicardial distribution of perfusion reserve may be demonstrated with static CT perfusion. Low MPR in all myocardial layers was observed specifically in obese patients....

  16. Detection of perfusion abnormalities in patients with permanent pacemakers on stress-rest 99mTc-tetrofosmin myocardial perfusion single-photon emission computed tomography: comparison between right ventricular apex and right ventricular outflow tract pacing.

    Science.gov (United States)

    Das, Kalpa J; Patel, Chetan D; Sharma, Gautam; Naik, Nitish; Singh, Harmandeep

    2016-04-01

    The aim of the study was to compare the myocardial perfusion defects in patients with right ventricular outflow tract (RVOT) and right ventricular apex (RVA) pacing on stress-rest Tc-tetrofosmin myocardial perfusion single-photon emission computed tomography. A total of 31 patients with permanent pacemakers (RVOT: 16 and RVA: 15) underwent stress-rest Tc-tetrofosmin involving a 1-day protocol. All patients underwent 1-day low-dose stress-gated and high-dose rest-gated Tc-tetrofosmin myocardial perfusion single-photon emission computed tomography imaging. Fixed perfusion defects were noted in 13 (42%) of 31 patients. Two (13%) patients of the RVOT group and 11 (69%) patients of the RVA group showed fixed perfusion defects (P=0.003). The fixed perfusion defects were located in the anteroapical, anteroseptal, and apical in the RVOT pacing group and in the apical, distal anteroseptal, inferoapical, distal anterior, and distal inferoseptal in the RVA pacing group. On univariate analysis, the incidence of perfusion defects was significantly associated with apical pacing, longer pQRS duration, and higher percentage of ventricular pacing. On multivariate analysis, the site of pacemaker insertion was found to be the most important pacemaker parameter determining the incidence of perfusion defects. Importantly, the duration of postpacemaker implantation did not show any significant relation to the incidence of perfusion defects. Fixed perfusion abnormalities are observed in patients with pacemakers and are independent of duration of time since implantation. RVOT pacing is associated with fewer incidences of myocardial perfusion abnormalities compared with RVA pacing.

  17. Caffeine intake inverts the effect of adenosine on myocardial perfusion during stress as measured by T1 mapping.

    Science.gov (United States)

    Kuijpers, Dirkjan; Prakken, Niek H; Vliegenthart, Rozemarijn; van Dijkman, Paul R M; van der Harst, Pim; Oudkerk, Matthijs

    2016-10-01

    Caffeine intake before adenosine stress myocardial perfusion imaging may cause false negative findings. We hypothesized that the antagonistic effect of caffeine can be measured by T1 relaxation times in rest and adenosine stress cardiac magnetic resonance imaging (CMR), as T1 mapping techniques are sensitive to changes in myocardial blood volume. We prospectively analyzed 105 consecutive patients with adenosine stress perfusion CMR on a 1.5-T MRI system. Rest and stress T1 mapping was performed using Modified Look-Locker Inversion recovery. T1 reactivity was defined as difference in T1rest and T1stress (∆T1). Fifteen patients drank coffee within 4 h of CMR (8H caffeine group). Comparison was made to patients without self-reported coffee intake: 50 with normal CMR (control group), 18 with myocardial ischemia, and 12 with myocardial infarction. The national review board approved the study; all patients gave written informed consent. The T1 of -7.8 % (T1rest 975 ± 42 ms, T1stress 898 ± 51 ms, p 8H caffeine group showed reduced T1 reactivity (1.8 %; T1rest 979 ms, T1stress 997 ms) compared to the controls (4.3 %; T1rest 977 ± 40 ms, T1stress 1018 ± 40 ms), p infarcted myocardium showed minimal T1 reactivity (0.2 and 0.3 %, respectively). Caffeine intake inverts the adenosine effect during stress perfusion CMR as measured by T1 mapping. T1 reactivity can assess the adequacy of adenosine-induced stress in perfusion CMR.

  18. MIBI Uptake in a Huge Breast Mass Obscuring the Anterior and Lateral Myocardial Walls in Perfusion Imaging

    OpenAIRE

    Forough Kalantari; Mehrshad Abbasi; Saeed Farzanefar

    2015-01-01

    Background: Cardiac risk assessment with myocardial perfusion imaging (MPI) is a common practice for some elderly breast cancer patients who are candidates for operation. In rare cases the tumor may become visible in the images.Case presentation: This is the report of a case with a huge slow-growing breast tumor suspicious for malignancy and presenting with methoxy-isobutyl-isonitrile (MIBI) uptake in the tumor. The patient was referred to the nuclear medicine department for preoperative card...

  19. Regadenoson in Europe: first-year experience of regadenoson stress combined with submaximal exercise in patients undergoing myocardial perfusion scintigraphy

    OpenAIRE

    Brinkert, M.; Reyes, E.; Walker, S.; Latus, K.; Maenhout, A.; Mizumoto, R.; Nkomo, C.; Standbridge, K.; Wechalekar, K.; Underwood, S. R.

    2013-01-01

    Purpose Regadenoson was approved for clinical use in Europe in 2011. Since then, it has become the default form of stress at our institution. We have assessed the side-effect profile and tolerability of regadenoson in patients undergoing clinically indicated myocardial perfusion scintigraphy between July 2011 and July 2012. Methods Clinical, stress and imaging data were recorded prospectively. Symptoms during stress were recorded and defined as mild, moderate or severe. An adverse event was d...

  20. Influence of chronic inflammation and autoimmunity on coronary calcifications and myocardial perfusion defects in systemic lupus erythematosus patients

    OpenAIRE

    Plazak, Wojciech; Pasowicz, Mieczyslaw; Kostkiewicz, Magdalena; Podolec, Jakub; Tomkiewicz-Pajak, Lidia; Musial,Jacek; Podolec, Piotr

    2011-01-01

    Objective Conventional risk factors for coronary artery disease fail to explain the increased frequency or cardiovascular morbidity in systemic lupus erythematosus (SLE) patients. This study was conducted to determine the possible influence of autoimmune and inflammatory phenomena markers on coronary artery calcifications and myocardial perfusion abnormalities in SLE patients. Materials and methods Multi-detector computed tomography (MDCT)-based coronary calcium scoring and single photon emis...

  1. Direct parametric reconstruction in dynamic PET myocardial perfusion imaging: in vivo studies

    Science.gov (United States)

    Petibon, Yoann; Rakvongthai, Yothin; El Fakhri, Georges; Ouyang, Jinsong

    2017-05-01

    Dynamic PET myocardial perfusion imaging (MPI) used in conjunction with tracer kinetic modeling enables the quantification of absolute myocardial blood flow (MBF). However, MBF maps computed using the traditional indirect method (i.e. post-reconstruction voxel-wise fitting of kinetic model to PET time-activity-curves-TACs) suffer from poor signal-to-noise ratio (SNR). Direct reconstruction of kinetic parameters from raw PET projection data has been shown to offer parametric images with higher SNR compared to the indirect method. The aim of this study was to extend and evaluate the performance of a direct parametric reconstruction method using in vivo dynamic PET MPI data for the purpose of quantifying MBF. Dynamic PET MPI studies were performed on two healthy pigs using a Siemens Biograph mMR scanner. List-mode PET data for each animal were acquired following a bolus injection of ~7-8 mCi of 18F-flurpiridaz, a myocardial perfusion agent. Fully-3D dynamic PET sinograms were obtained by sorting the coincidence events into 16 temporal frames covering ~5 min after radiotracer administration. Additionally, eight independent noise realizations of both scans—each containing 1/8th of the total number of events—were generated from the original list-mode data. Dynamic sinograms were then used to compute parametric maps using the conventional indirect method and the proposed direct method. For both methods, a one-tissue compartment model accounting for spillover from the left and right ventricle blood-pools was used to describe the kinetics of 18F-flurpiridaz. An image-derived arterial input function obtained from a TAC taken in the left ventricle cavity was used for tracer kinetic analysis. For the indirect method, frame-by-frame images were estimated using two fully-3D reconstruction techniques: the standard ordered subset expectation maximization (OSEM) reconstruction algorithm on one side, and the one-step late maximum a posteriori (OSL-MAP) algorithm on the other

  2. Direct parametric reconstruction in dynamic PET myocardial perfusion imaging: in vivo studies.

    Science.gov (United States)

    Petibon, Yoann; Rakvongthai, Yothin; El Fakhri, Georges; Ouyang, Jinsong

    2017-05-07

    Dynamic PET myocardial perfusion imaging (MPI) used in conjunction with tracer kinetic modeling enables the quantification of absolute myocardial blood flow (MBF). However, MBF maps computed using the traditional indirect method (i.e. post-reconstruction voxel-wise fitting of kinetic model to PET time-activity-curves-TACs) suffer from poor signal-to-noise ratio (SNR). Direct reconstruction of kinetic parameters from raw PET projection data has been shown to offer parametric images with higher SNR compared to the indirect method. The aim of this study was to extend and evaluate the performance of a direct parametric reconstruction method using in vivo dynamic PET MPI data for the purpose of quantifying MBF. Dynamic PET MPI studies were performed on two healthy pigs using a Siemens Biograph mMR scanner. List-mode PET data for each animal were acquired following a bolus injection of ~7-8 mCi of 18 F-flurpiridaz, a myocardial perfusion agent. Fully-3D dynamic PET sinograms were obtained by sorting the coincidence events into 16 temporal frames covering ~5 min after radiotracer administration. Additionally, eight independent noise realizations of both scans-each containing 1/8th of the total number of events-were generated from the original list-mode data. Dynamic sinograms were then used to compute parametric maps using the conventional indirect method and the proposed direct method. For both methods, a one-tissue compartment model accounting for spillover from the left and right ventricle blood-pools was used to describe the kinetics of 18 F-flurpiridaz. An image-derived arterial input function obtained from a TAC taken in the left ventricle cavity was used for tracer kinetic analysis. For the indirect method, frame-by-frame images were estimated using two fully-3D reconstruction techniques: the standard ordered subset expectation maximization (OSEM) reconstruction algorithm on one side, and the one-step late maximum a posteriori (OSL-MAP) algorithm on the other

  3. [Acute stent thrombosis and reverse transient left ventricular dilatation after performing a single-photon emission computed tomography myocardial perfusion].

    Science.gov (United States)

    Miranda, B; Pizzi, M N; Aguadé-Bruix, S; Domingo, E; Candell-Riera, J

    2015-01-01

    A 63-year-old male patient with a history of stent implantation in the left anterior descending three months before. Due to the presentation of vegetative symptoms, he was referred for gated-SPECT myocardial perfusion. During acquisition of the resting images he presented chest pain and ST segment elevation, so that urgent cardiac catheterization was performed, showing stent thrombosis. Rest perfusion imaging showed a defect in anterior and apical perfusion, more severe and extensive than in the stress images, with striking left ventricular dilatation and a fall in the ejection fraction related to the acute ischemia phenomenon. Intense exercise is associated with a transient activation of the coagulation system and hemodynamic changes that might induce thrombosis, especially in recently implanted coronary stents that probably still have not become completely endothelialized. Copyright © 2014 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  4. Mild troponin I elevation does not predict ischemia on myocardial perfusion imaging

    Directory of Open Access Journals (Sweden)

    Le Dung Ha

    2017-08-01

    Full Text Available IntroductionData are limited on the degree of mild troponin I elevation and clinical risk factors in predicting myocardial ischemia.MethodsHospitalized adult patients who underwent myocardial perfusion imaging (MPI from 2015 to 2016 at Rochester General Hospital and had mild troponin I elevation (>0.1 and <1.5 ng/mL were included. Predictors of outcomes were determined using logistic regression model.ResultsOne hundred and sixty-six patients with mild troponin I elevation who underwent MPI were followed. Mean age was 69.6 ± 12.5 years and 53.0% of the patients were female. Fourteen patients (8.4% presented with typical chest pain (CP, 60 patients (36.1% had atypical CP and 92 patients (55.4% had no CP on presentation. MPI was positive for ischemia in 45 patients (27.1%. There was no difference in peak troponin I level with ischemia versus no ischemia on MPI (0.34 ng/dL [0.13-0.69] vs. 0.23 ng/dL [0.14-0.50], p value 0.254. Atypical CP did not predict the presence of ischemia on MPI (odds ratio [OR] 1.97, 95% confidence interval [CI] 0.91-4.26. Coronary artery disease (CAD history (age and sex adjusted p value 0.013, diabetes (adjusted p value 0.036, creatinine ≥2 mg/dL (adjusted p value 0.019 and dialysis (adjusted p value 0.006 were statistically significant predictors of ischemia on MPI.ConclusionsIn patients presenting with mild troponin I elevation, peak troponin I level did not predict ischemia on MPI. The presence of CAD history, diabetes, elevated creatinine and dialysis were predictors of ischemia on MPI.

  5. Coronary risk factors and myocardial perfusion in asymptomatic adults: the Multi-Ethnic Study of Atherosclerosis (MESA).

    Science.gov (United States)

    Wang, Lu; Jerosch-Herold, Michael; Jacobs, David R; Shahar, Eyal; Folsom, Aaron R

    2006-02-07

    The purpose of this study was to determine the cross-sectional relation between myocardial perfusion and coronary heart disease (CHD) risk factors among adults with no clinical CHD. Clinical studies suggest that myocardial perfusion is often abnormal in individuals without CHD but with risk factors. Epidemiologic study in asymptomatic populations is lacking. Two hundred twenty-two men and women, ages 45 to 84 years and free of a CHD diagnosis, in the University of Minnesota field center of the Multi-Ethnic Study of Atherosclerosis (MESA) had myocardial blood flow (MBF) determined using cardiac magnetic resonance imaging at rest and during adenosine-induced hyperemia. Perfusion reserve (PR) was calculated as the ratio of hyperemic to rest MBF. Both resting and hyperemic MBF were lower in men than in women, even after considering age and menopause. Hyperemic MBF was also significantly lower in subjects who were older, and in those with higher blood pressure, higher fasting glucose, and lower low-density lipoprotein cholesterol. After adjusting for age, gender, and race, reduced PR was independently associated with hypertension, higher diastolic blood pressure, and higher total and low-density lipoprotein cholesterol, but was not associated with cigarette smoking, obesity, physical activity, or diabetes. Moreover, hyperemic MBF and PR were correlated strongly and inversely with estimated 10-year CHD risk based on Framingham equations (p for trends: adults without symptomatic CHD.

  6. Technetium-99m sestamibi single-photon emission tomography detects subclinical myocardial perfusion abnormalities in patients with systemic lupus erythematosus

    Energy Technology Data Exchange (ETDEWEB)

    Schillaci, O. [Nuclear Medicine, University of l`Aquila (Italy); Lagana, B.; Gentile, R.; Tubani, L.; Baratta, L. [Department of Clinical Medicine, University ``La Sapienza``, Rome (Italy); Danieli, R.; Scopinaro, F. [Section of Nuclear Medicine, Department of Experimental Medicine and Pathology, University ``La Sapienza``, Rome (Italy)

    1999-07-01

    In patients with systemic lupus erythematosus, involvement of the cardiovascular system is the third leading cause of death. However, although autopsy studies have demonstrated a high incidence of abnormalities in both the myocardium and coronary vessels, clinical manifestations have been reported in only a small percentage of cases. The aim of this study was to evaluate myocardial perfusion in asymptomatic lupus patients using technetium-99m sestamibi single-photon emission tomography (SPET). Twenty-eight patients without overt cardiac involvement and risk factors were studied with {sup 99m}Tc-sestamibi SPET at rest and after dipyridamole infusion. Perfusion abnormalities were detected in 18 cases: six had persistent defects, three had reversible defects, seven had both persistent and reversible defects, and two showed rest defects which normalized on dipyridamole images (``reverse redistribution pattern``). Coronary angiography was performed in eight patients with positive {sup 99m}Tc-sestamibi SPET, and showed normal epicardial vessels in all the cases. These results indicate that {sup 99m}Tc-sestamibi SPET reveals a high prevalence (18 out of 28 patients in this study, i.e. 64%) of myocardial perfusion abnormalities in asymptomatic lupus patients, probably due to the primary immunological damage of this autoimmune disease. In conclusion, rest/dipyridamole {sup 99m}Tc-sestamibi SPET can be a useful non-invasive method to identify subclinical myocardial involvement in systemic lupus erythematosus, and patients potentially at risk of later cardiac events. (orig.) With 2 figs., 2 tabs., 21 refs.

  7. Prediction of 9-year cardiovascular outcomes by myocardial perfusion imaging in patients with normal exercise electrocardiographic testing.

    Science.gov (United States)

    Schinkel, Arend F L; Boiten, Henk J; van der Sijde, Jors N; Ruitinga, Pauline R; Sijbrands, Eric J G; Valkema, Roelf; van Domburg, Ron T

    2012-11-01

    Exercise myocardial perfusion imaging (MPI) is widely used, but the long-term prognostic value of this test in patients with normal exercise electrocardiographic testing is not defined. A consecutive group of 650 patients (428 men, mean age: 56 ± 11 years) with known or suspected coronary artery disease underwent exercise electrocardiographic testing and MPI. Follow-up endpoints were mortality and major adverse cardiac events (MACE). Predictors of outcome were identified by multivariate logistic regression analysis using clinical, exercise electrocardiographic testing and single-photon emission computed tomography (SPECT) variables. A total of 324 (50%) patients had an abnormal SPECT, and 131 (20%) had completely or partially reversible perfusion defects. During a mean follow-up of 9.2 ± 2.0 years, 107 (23%) patients died, 69 (11%) had a non-fatal myocardial infarction, 90 (14%) underwent coronary artery bypass surgery, and 142 (22%) percutaneous coronary intervention. Multivariate analysis demonstrated that the summed rest score was an independent predictor of mortality [hazard ratio (HR): 1.15, 95% confidence interval (CI): (1.08-1.22], P exercise electrocardiographic testing data provided incremental prognostic information for the prediction of mortality and MACE (both P exercise electrocardiographic testing have completely or partially reversible myocardial perfusion defects. MPI provides additional information for the prediction of 9-year cardiovascular outcomes in these patients.

  8. Prevalence of symptomatic and silent stress-induced perfusion defects in diabetic patients with suspected coronary artery disease referred for myocardial perfusion scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Prior, John O.; Calcagni, Maria-Lucia; Bischof Delaloye, Angelika [Centre Hospitalier Universitaire Vaudois (CHUV University Hospital), Division of Nuclear Medicine, Lausanne (Switzerland); Monbaron, David; Ruiz, Juan [Centre Hospitalier Universitaire Vaudois (CHUV University Hospital), Division of Endocrinology, Diabetology and Metabolism, Lausanne (Switzerland); Koehli, Melanie [Centre Hospitalier Universitaire Vaudois (CHUV University Hospital), Division of Nuclear Medicine, Lausanne (Switzerland); Centre Hospitalier Universitaire Vaudois (CHUV University Hospital), Division of Endocrinology, Diabetology and Metabolism, Lausanne (Switzerland)

    2005-01-01

    Silent myocardial ischaemia - as evaluated by stress-induced perfusion defects on myocardial perfusion scintigraphy (MPS) in patients without a history of chest pain - is frequent in diabetes and is associated with increased rates of cardiovascular events. Its prevalence has been determined in asymptomatic diabetic patients, but remains largely unknown in diabetic patients with suspected coronary artery disease (CAD) in the clinical setting. In this study we therefore sought (a) to determine the prevalence of symptomatic and silent perfusion defects in diabetic patients with suspected CAD and (b) to characterise the eventual predictors of abnormal perfusion. The patient population comprised 133 consecutive diabetic patients with suspected CAD who had been referred for MPS. Studies were performed with exercise (41%) or pharmacological stress testing (1-day protocol, {sup 99m}Tc-sestamibi, {sup 201}Tl or both). We used semi-quantitative analysis (20-segment polar maps) to derive the summed stress score (SSS) and the summed difference score (SDS). Abnormal MPS (SSS{>=}4) was observed in 49 (37%) patients (SSS=4.9{+-}8.4, SDS=2.4{+-}4.7), reversible perfusion defects (SDS{>=}2) in 40 (30%) patients [SSS=13.3{+-}10.9; SDS=8.0{+-}5.6; 20% moderate to severe (SDS>4), 7% multivessel] and fixed defects in 21 (16%) patients. Results were comparable between patients with and patients without a history of chest pain. Of 75 patients without a history of chest pain, 23 (31%, 95% CI=21-42%) presented reversible defects (SSS=13.9{+-}11.3; SDS=7.4{+-}1.2), indicative of silent ischaemia. Reversible defects were associated with inducible ST segment depression during MPS stress (odds ratio (OR)=3.2, p<0.01). Fixed defects were associated with erectile dysfunction in males (OR=3.7, p=0.02) and lower aspirin use (OR=0.25, p=0.02). Silent stress-induced perfusion defects occurred in 31% of the patients, a rate similar to that in patients with a history of chest pain. MPS could identify

  9. Diagnostic accuracy of combined coronary angiography and adenosine stress myocardial perfusion imaging using 320-detector computed tomography: pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Nasis, Arthur; Ko, Brian S.; Leung, Michael C.; Antonis, Paul R.; Wong, Dennis T.; Kyi, Leo; Cameron, James D.; Meredith, Ian T.; Seneviratne, Sujith K. [Southern Health and Monash University, Monash Cardiovascular Research Centre, Monash Heart, Department of Medicine Monash Medical Centre (MMC), Melbourne (Australia); Nandurkar, Dee; Troupis, John M. [MMC, Southern Health, Department of Diagnostic Imaging, Melbourne (Australia)

    2013-07-15

    To determine the diagnostic accuracy of combined 320-detector row computed tomography coronary angiography (CTA) and adenosine stress CT myocardial perfusion imaging (CTP) in detecting perfusion abnormalities caused by obstructive coronary artery disease (CAD). Twenty patients with suspected CAD who underwent initial investigation with single-photon-emission computed tomography myocardial perfusion imaging (SPECT-MPI) were recruited and underwent prospectively-gated 320-detector CTA/CTP and invasive angiography. Two blinded cardiologists evaluated invasive angiography images quantitatively (QCA). A blinded nuclear physician analysed SPECT-MPI images for fixed and reversible perfusion defects. Two blinded cardiologists assessed CTA/CTP studies qualitatively. Vessels/territories with both >50 % stenosis on QCA and corresponding perfusion defect on SPECT-MPI were defined as ischaemic and formed the reference standard. All patients completed the CTA/CTP protocol with diagnostic image quality. Of 60 vessels/territories, 17 (28 %) were ischaemic according to QCA/SPECT-MPI criteria. Sensitivity, specificity, PPV, NPV and area under the ROC curve for CTA/CTP was 94 %, 98 %, 94 %, 98 % and 0.96 (P < 0.001) on a per-vessel/territory basis. Mean CTA/CTP radiation dose was 9.2 {+-} 7.4 mSv compared with 13.2 {+-} 2.2 mSv for SPECT-MPI (P < 0.001). Combined 320-detector CTA/CTP is accurate in identifying obstructive CAD causing perfusion abnormalities compared with combined QCA/SPECT-MPI, achieved with lower radiation dose than SPECT-MPI. (orig.)

  10. The clinical role of stress myocardial perfusion imaging in women with suspected coronary artery disease.

    Science.gov (United States)

    Mieres, Jennifer H; Rosman, David R; Shaw, Leslee J

    2004-01-01

    Cardiovascular disease remains the number one cause of mortality for women in the United States, with coronary artery disease (CAD) accounting for 54% of all cardiovascular deaths. CAD claims the lives of more than 250,000 women each year and is therefore the single largest killer of American women. For several decades, the under-representation of women in clinical trials led to both a lack of available sex-specific evidence and a generalized misconception that CAD was a "man's disease." In actuality, not only are women vulnerable to CAD, they typically develop it 10 to 15 years later than men. Furthermore, sex differences exist in the mortality rates of women and men with CAD, such that once CAD is present in women, they have worse outcomes than their male counterparts. Consequently, early and accurate diagnosis of CAD is crucial for reducing mortality rates in women. Stress myocardial perfusion imaging (MPI) using contemporary techniques has been shown to have significant value in the diagnosis and prognosis of CAD in women. In the risk assessment of women with an intermediate clinical pretest likelihood of CAD, using MPI with exercise or pharmacologic stress has been shown to add incremental value to clinical variables or exercise electrocardiogram stress testing alone. This review discusses the clinical role of stress MPI in the management of women with suspected CAD.

  11. Safety and tolerability of regadenoson for myocardial perfusion imaging - first Danish experience.

    Science.gov (United States)

    Pape, Marianne; Zacho, Helle D; Aarøe, Jens; Eggert Jensen, Svend; Petersen, Lars J

    2016-06-01

    Evaluating safety and tolerability of the selective A2A receptor agonist, regadenoson, in patients referred for single photon emission computed tomography myocardial perfusion imaging (MPI). Observational study of patients referred for MPI stress testing using a 400 μg regadenoson (Rapiscan(®)) bolus. Hemodynamic variables and severity of adverse events (AE) were recorded before, during, and after administration. A total of 232 patients were included. One or more AE were reported in 90% of patients; the AEs were graded mostly mild to moderate in severity, resolved spontaneously, and were mainly dyspnea, headache, and chest pain. No advanced heart block or bronchospasm were seen. Transient ST-segment changes developed in 10 patients. The maximum increase in heart rate was 19 ± 11 beats/minute. The mean systolic blood pressure decreased from 144 to 139 mmHg (p regadenoson. Regadenoson for MPI is easy to use with a high frequency of AEs, which are generally mild in severity, transient, and resolve spontaneously.

  12. Value of attenuation correction in stress-only myocardial perfusion imaging using CZT-SPECT.

    Science.gov (United States)

    van Dijk, J D; Mouden, M; Ottervanger, J P; van Dalen, J A; Knollema, S; Slump, C H; Jager, P L

    2017-04-01

    Attenuation correction (AC) improves the diagnostic outcome of stress-only myocardial perfusion imaging (MPI) using conventional SPECT. Our aim was to determine the value of AC using a cadmium zinc telluride-based (CZT)-SPECT camera. We retrospectively included 107 consecutive patients who underwent stress-optional rest MPI CZT-SPECT/CT. Next, we created three types of images for each patient; (1) only displaying reconstructed data without the CT-based AC (NC), (2) only displaying AC, and (3) with both NC and AC (NC + AC). Next, two experienced physicians visually interpreted these 321 randomized images as normal, equivocal, or abnormal. Image outcome was compared with all hard events over a mean follow-up time of 47.7 ± 9.8 months. The percentage of images interpreted as normal increased from 45% using the NC images to 72% using AC and to 67% using NC + AC images (P < .001). Hard event hazard ratios for images interpreted as normal were not different between using NC and AC (1.01, P = .99), or NC and NC + AC images (0.97, P = .97). AC lowers the need for additional rest imaging in stress-first MPI using CZT-SPECT, while long-term patient outcome remained identical. Use of AC reduces the need for additional rest imaging, decreasing the mean effective dose by up to 1.2 mSv.

  13. Diagnostic performance of fusion of myocardial perfusion imaging (MPI) and computed tomography coronary angiography

    Science.gov (United States)

    Santana, Cesar A.; Garcia, Ernest V.; Faber, Tracy L.; Sirineni, Gopi K. R.; Esteves, Fabio P.; Sanyal, Rupan; Halkar, Raghuveer; Ornelas, Mario; Verdes, Liudmila; Lerakis, Stamatios; Ramos, Julie J.; Aguadé-Bruix, Santiago; Cuéllar, Hugo; Candell-Riera, Jaume; Raggi, Paolo

    2011-01-01

    Background We evaluated the incremental diagnostic value of fusion images of coronary computed tomography angiography (CTA) and myocardial perfusion imaging (MPI) over MPI alone or MPI and CTA side-by-side to identify obstructive coronary artery disease (CAD > 50% stenosis) using invasive coronary angiography (ICA) as the gold standard. Methods 50 subjects (36 men; 56 ± 11 years old) underwent rest-stress MPI and CTA within 12-26 days of each other. CTAs were performed with multi-detector CT-scanners (31 on 64-slice; and 19 on 16-slice). 37 patients underwent ICA while 13 subjects did not because of low (area under the curve (AUC) for fused images: 0.89; P = .005 vs MPI, P = .04 vs side-by-side MPI-CTA) and for localization of CAD to the left anterior descending coronary artery (AUC: 0.82, P < .001 vs MPI; P = .007 vs side-by-side MPI-CTA). There was a non-significant trend for better detection of multi-vessel disease with fusion. Conclusions Using ICA as the gold standard, fusion imaging provided incremental diagnostic information compared to MPI alone or side-by-side MPI-CTA for the diagnosis of obstructive CAD and for localization of CAD to the left anterior descending coronary artery. PMID:19156478

  14. (13)N-Ammonia PET/CT Detection of Myocardial Perfusion Abnormalities in Beagle Dogs After Local Heart Irradiation.

    Science.gov (United States)

    Song, Jianbo; Yan, Rui; Wu, Zhifang; Li, Jianguo; Yan, Min; Hao, Xinzhong; Liu, Jianzhong; Li, Sijin

    2017-04-01

    Our objective was to determine the potential value of (13)N-ammonia PET/CT myocardial perfusion imaging (MPI) for early detection of myocardial perfusion changes induced by radiation damage. Methods: Thirty-six Beagle dogs were randomly divided into a control group (n = 18) or an irradiation group (n = 18). The latter underwent local irradiation to the left ventricular anterior cardiac wall with a single dose of 20 Gy, whereas the former received sham irradiation. All dogs underwent (13)N-ammonia PET/CT MPI 1 wk before irradiation and at 3, 6, and 12 mo after sham or local irradiation. One week after undergoing (13)N-ammonia PET/CT MPI, the irradiation group underwent coronary angiography. Six randomly selected dogs from each group were sacrificed and used to detect pathologic cardiac injury at 3, 6, and 12 mo after irradiation. Results: Compared with the control group and baseline, the irradiation group showed significantly increased perfusion in the irradiated area of the heart at 3 mo after irradiation, perfusion reduction at 6 mo after irradiation, and a perfusion defect at 12 mo after irradiation. There was no significant difference in the left ventricular ejection fraction between the control and irradiation groups at baseline or at 3 mo after irradiation. The irradiation group showed a reduction of left ventricular ejection fraction compared with the control group at 6 mo (50.0% ± 8.1% vs. 59.3% ± 4.1%, P = 0.016) and 12 mo (47.2% ± 6.7% vs. 57.4% ± 3.3%, P = 0.002) after irradiation. No coronary stenosis was observed in the irradiation group. Regional wall motion abnormalities appeared in the irradiated area at 6 mo after irradiation, and its extent was enlarged at 12 mo after irradiation. Pathologic changes were observed; radiation-induced myocardial tissue damage and microvascular fibrosis in the irradiated area progressively increased over time. Conclusion:(13)N-ammonia PET/CT MPI can dynamically detect myocardial perfusion changes together with

  15. Myocardial perfusion SPECT in stable angina;Place de la scintigraphie myocardique dans l'angor stable

    Energy Technology Data Exchange (ETDEWEB)

    Jau, P.; Jacob, T. [HP Clairval, Service de medecine nucleaire, 13 - Marseille (France); Lecorff, G.; Bouvier, J.L.; Novella, P.; Bechet, V.; Pelet, V. [HP Clairval, Service de cardiologie, 13 - Marseille (France)

    2010-03-15

    We study the precise contribution of myocardial scintigraphy in the therapeutic management of stable coronary artery disease. Until recently, treatment was focused on revascularization, often by coronary angioplasty.Recent studies have challenged this practice by showing the absence of superiority of angioplasty compared to optimal medical therapy.The problem now is to define for each stable coronary artery disease, and individually, the best of both treatment options. In this spirit, the functional approach to coronary artery disease by myocardial perfusion scintigraphy is most interesting.The diagnostic performance, including sensitivity and negative predictive value, and the prognostic value of the technique are clearly established. Recent studies show that a therapeutic decision based on a functional approach to the patient is valid.We need to know this development in cardiology for best position in the multidisciplinary discussions, myocardial scintigraphy as a functional approach to stable coronary artery disease. (N.C.)

  16. Dual-energy CT perfusion during pharmacologic stress for the assessment of myocardial perfusion defects using a second-generation dual-source CT: a comparison with cardiac magnetic resonance imaging.

    Science.gov (United States)

    Kim, Sung Mok; Chang, Sung-A; Shin, Wonseon; Choe, Yeon Hyeon

    2014-01-01

    This study aimed to assess the diagnostic performance of adenosine-stress dual-energy myocardial computed tomography perfusion (DECTP) imaging using 128-slice dual-source computed tomography (CT) for the detection of myocardial perfusion defects in comparison with stress-perfusion magnetic resonance imaging (MRI). This prospective study included 50 patients (mean age, 66 [9] years; 64% men) with suspected coronary artery disease who underwent adenosine-stress DECTP using 128-slice dual-source CT as well as adenosine-stress cardiac MRI using a 1.5-T scanner. Estimates of diagnostic accuracy in detecting myocardial perfusion defects were calculatedand compared with those of cardiac MRI. The estimates of diagnostic accuracy in detecting myocardial perfusion defects using DECTP were as follows: sensitivity, 77% (95% confidence interval [CI], 67%-87%); specificity, 94% (95% CI, 92%-95%); positive predictive value, 53% (95% CI, 44%-63%); and negative predictive value, 98% (95% CI, 97%-99%). The results of DECTP imaging were positively correlated with those of cardiac MRI (r = 0.602, P stress DECTP imaging and rest coronary CTA were 6.5 (2.2) and 4.9 (1.7) mSv, respectively. Adenosine-stress DECTP imaging enables detection of myocardial ischemia. However, further technical developments are necessary to reduce artifacts and improve the sensitivity of DECTP.

  17. High resolution myocardial magnetic resonance stress perfusion imaging at 3 T using a 1 M contrast agent

    Energy Technology Data Exchange (ETDEWEB)

    Klumpp, Bernhard D.; Seeger, Achim; Doering, Joerg; Kramer, Ulrich; Fenchel, Michael; Claussen, Claus D.; Miller, Stephan [Eberhard Karls University Tuebingen, Department for Diagnostic Radiology, Tuebingen (Germany); Doesch, Christina; Hoevelborn, Tobias; Gawaz, Meinrad P. [Eberhard Karls University Tuebingen, Department for Cardiology, Tuebingen (Germany)

    2010-03-15

    Stress perfusion magnetic resonance imaging (MSPMRI) is an established technique for the assessment of myocardial perfusion. Shortcomings at 1.5 T are low signal to noise ratio (SNR) and contrast to noise ratio (CNR). One approach to overcome these shortcomings is to increase field strength and contrast concentration. The aim of our study was to investigate the diagnostic capability of high resolution MSPMRI at 3-T field strength using a 1 M contrast agent. Fifty-seven patients (62.3{+-} 11.0 years) with symptoms of coronary artery disease (CAD) were examined at 3 T. MMRSPI was assessed using a 2D saturation recovery gradient echo (SR GRE) sequence in short axis orientation (TR 1.9 ms, TE 1.0 ms, flip 12 , 0.1 mmol gadobutrol/kg body weight (bw), 140{mu}g adenosine/kg bw/min). Perfusion images were assessed visually and semiquantitatively (upslope, peak signal intensity (SI), and myocardial perfusion reserve index (MPRI)). Standard of reference was invasive coronary angiography. Stress-induced hypoperfusion was found in 43 patients. Sensitivity for hemodynamically relevant CAD (stenoses greater than 70%) was 95%/98%, specificity 80%/87%, diagnostic accuracy 91%/95% (reader 1/reader 2). The MPRI was significantly lower in hypoperfused myocardium (1.3 {+-} 0.2) compared with normal myocardium (2.6 {+-} 0.7). High resolution MMRSPI at 3 T using 1 M contrast agent under daily routine conditions provides reliable detection of stress-induced myocardial hypoperfusion with higher diagnostic accuracy than 1.5-T conditions. (orig.)

  18. MYOCARDIAL PROTECTION DURING CORONARY ANGIOPLASTY WITH AUTOPERFUSION AND FORCED PERFUSION - AN IN-VITRO COMPARISON

    NARCIS (Netherlands)

    DEMUINCK, ED; VERKERKE, BJ; RAKHORST, G; LIE, KI

    During coronary angioplasty, perfusion distal to the inflated angioplasty balloon can be maintained with autoperfusion balloon catheters and coronary perfusion pumps. The blood flow rates through the autoperfusion balloon catheters and the flow rates achieved with a perfusion pump were compared in

  19. Optimization and comparison of simultaneous and separate acquisition protocols for dual isotope myocardial perfusion SPECT

    Science.gov (United States)

    Ghaly, Michael; Links, Jonathan M.; Frey, Eric C.

    2015-07-01

    Dual-isotope simultaneous-acquisition (DISA) rest-stress myocardial perfusion SPECT (MPS) protocols offer a number of advantages over separate acquisition. However, crosstalk contamination due to scatter in the patient and interactions in the collimator degrade image quality. Compensation can reduce the effects of crosstalk, but does not entirely eliminate image degradations. Optimizing acquisition parameters could further reduce the impact of crosstalk. In this paper we investigate the optimization of the rest Tl-201 energy window width and relative injected activities using the ideal observer (IO), a realistic digital phantom population and Monte Carlo (MC) simulated Tc-99m and Tl-201 projections as a means to improve image quality. We compared performance on a perfusion defect detection task for Tl-201 acquisition energy window widths varying from 4 to 40 keV centered at 72 keV for a camera with a 9% energy resolution. We also investigated 7 different relative injected activities, defined as the ratio of Tc-99m and Tl-201 activities, while keeping the total effective dose constant at 13.5 mSv. For each energy window and relative injected activity, we computed the IO test statistics using a Markov chain Monte Carlo (MCMC) method for an ensemble of 1,620 triplets of fixed and reversible defect-present, and defect-absent noisy images modeling realistic background variations. The volume under the 3-class receiver operating characteristic (ROC) surface (VUS) was estimated and served as the figure of merit. For simultaneous acquisition, the IO suggested that relative Tc-to-Tl injected activity ratios of 2.6-5 and acquisition energy window widths of 16-22% were optimal. For separate acquisition, we observed a broad range of optimal relative injected activities from 2.6 to 12.1 and acquisition energy window of widths 16-22%. A negative correlation between Tl-201 injected activity and the width of the Tl-201 energy window was observed in these ranges. The results

  20. Feasibility of one-eighth time gated myocardial perfusion SPECT functional imaging using IQ-SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Caobelli, Federico; Thackeray, James T.; Bengel, Frank M. [Medizinische Hochschule Hannover, Klinik fuer Nuklearmedizin, Hannover (Germany); Soffientini, Alberto; Pizzocaro, Claudio; Guerra, Ugo Paolo [Fondazione Poliambulanza, Department of Nuclear Medicine, Brescia (Italy)

    2015-11-15

    IQ-SPECT, an add-on to general purpose cameras based on multifocal collimation, can reduce myocardial perfusion imaging (MPI) acquisition times to one-fourth that of standard procedures (to 12 s/view). In a phantom study, a reduction of the acquisition time to one-eighth of the standard time (to 6 s/view) was demonstrated as feasible. It remains unclear whether such a reduction could be extended to clinical practice. Fifty patients with suspected or diagnosed CAD underwent a 2-day stress-rest {sup 99m}Tc-sestamibi MPI protocol. Two consecutive SPECT acquisitions (6 and 12 s/view) were performed. Electrocardiogram-gated images were reconstructed with and without attenuation correction (AC). Polar maps were generated and visually scored by two blinded observers for image quality and perfusion in 17 segments. Global and regional summed stress score (SSS), summed rest score (SRS) and summed difference score (SDS) were determined. Left ventricular volumes and ejection fraction were calculated based on automated contour detection. Image quality was scored higher with the 12 s/view acquisition, both with and without AC. Summed scores were statistically comparable between the 6 s/view and the 12 s/view acquisition, both globally and in individual coronary territories (e.g. in images with AC, SSS were 6.6 ± 8.3 and 6.2 ± 8.2 with 6 s and 12 s/view, respectively, p = 0.10; SRS were 3.9 ± 5.6 and 3.5 ± 5.3, respectively, p = 0.19; and SDS were 2.8 ± 5.7 and 2.6 ± 5.7, respectively, p = 0.59). Both acquisitions allowed MPI-based diagnosis of CAD in 25 of the 50 patients (with AC). Calculated end-diastolic volume (EDV) and end-systolic volume (ESV) were modestly higher with the 6 s/view acquisition than with the 12 s/view acquisition (EDV +4.8 ml at rest and +3.7 ml after stress, p = 0.003; ESV +4.1 ml at rest and +2.6 ml after stress, p = 0.01), whereas the ejection fraction did not differ (-1.2 % at rest, p = 0.20, and -0.9 % after stress, p = 0.27). Image quality and

  1. Influence of chronic inflammation and autoimmunity on coronary calcifications and myocardial perfusion defects in systemic lupus erythematosus patients.

    Science.gov (United States)

    Plazak, Wojciech; Pasowicz, Mieczyslaw; Kostkiewicz, Magdalena; Podolec, Jakub; Tomkiewicz-Pajak, Lidia; Musial, Jacek; Podolec, Piotr

    2011-10-01

    Conventional risk factors for coronary artery disease fail to explain the increased frequency or cardiovascular morbidity in systemic lupus erythematosus (SLE) patients. This study was conducted to determine the possible influence of autoimmune and inflammatory phenomena markers on coronary artery calcifications and myocardial perfusion abnormalities in SLE patients. Multi-detector computed tomography (MDCT)-based coronary calcium scoring and single photon emission computerized tomography (SPECT) studies (Tc-99m sestamibi) were performed in 60 SLE patients in stable clinical condition, without a prior history of coronary artery disease. Laboratory evaluation included serum C-reactive protein (CRP), complement C3c and C4 components and antiphospholipid antibodies (aPL). The latter included anticardiolipin (aCL) and anti-β2-glycoprotein I (aβ2GPI) antibodies, of both IgG and IgM classes, and lupus anticoagulant (LA) in plasma. SPECT revealed persistent perfusion defects in 22 (36.7%) patients and exercise-induced defects in eight (13.3%), while MDCT revealed coronary calcifications in 15 (25%). Calcium scores ranged from 1 to 843.2 (mean 113.5 ± 259.7). No association was found between conventional coronary artery disease risk factors (obesity, hypertension, tobacco use, hyperlipidaemia, diabetes) nor CRP, C3c or C4 levels and coronary calcifications or myocardial perfusion defects. On the contrary, in patients with these pathologies, augmented autoimmunization was found, reflected by increased aCL IgG and antiβ2GPI IgG levels. In patients with aCL IgG >20 RU/ml or antiβ2GPI IgG >3 RU/ml, the relative risk of coronary calcification formation was 4.1 compared to patients with normal values. Accordingly, in LA-positive patients the relative risk of coronary calcification formation was 4.4 compared to LA-negative patients. Conventional risk factors for coronary artery disease as well as markers of an ongoing inflammation did not show any association with

  2. Prognosis of patients with positive exercise test and normal myocardial perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Seo, J. H.; Jeong, S. Y.; Bae, J. H.; Ahn, B. C.; Lee, J.; Lee, K. B [College of Medicine, Kyungpook National University, Daegu (Korea, Republic of)

    2004-07-01

    Exercise SPECT myocardial perfusion imaging(Ex-MPI) is regarded as a predictive technique particularly in patients with coronary artery disease(CAD) capable of performing exercise testing. In clinical practice, we encounter equivocal situations of discordant findings between exercise ECG and MPI. We evaluated the prognosis of subjects with positive ECG and normal MPI findings, and predictive factors for cardiac events. 2571 Ex-MPI studies were reviewed over a period of 3 years. Subjects were followed for more than 2 years(24-56 months, mean 35{+-}10months) for cardiac events after study. The cardiac events were defined as hard events(cardiac death and nonfatal myocardial infarction(MI)) and soft events(aggravation of CAD necessitating revascularization, congestive heart failure necessitating hospital admission). We evaluated age, sex, typical angina pain, rest ECG, hypertension, diabetes mellitus(DM), serum levels of cholesterol and LDL, smoking history, history of cerebrovascular disease(CVD) and peripheral artery disease(PAD), and rest left ventricular ejection fraction(LVEF) as clinical variables. Of 83 subjects with positive ECG and normal MPS findings, 6 were considered as false negative results confirmed with coronary angiography. There were 77 patients (mean age 52{+-}10 years, 39 males) with positive ECG and normal MPI results. During the follow-up period, of 77 there were 3 cardiac events (annual rate 1.9%), no cardiac death, 2 nonfatal MIs (annual rate 1.3%) and 1 soft event (annual rate 0.6%). 2/39 males(5.1%), and 1/38 females(2.6%) had cardiac events. All cardiac events were observed within 2 years. 1-year cardiac event rate was 0.6% and 2-year cardiac event rate was 1.9%. Among clinical factors, male sex, typical chest pain and smoking history at the time of MPI were predictive of cardiac events. Patients with positive ECG and negative EX-MPI results have low risk for cardiac events. Nevertheless, the cardiac events cannot be excluded totally in some

  3. Feasibility study of myocardial perfusion and oxygenation by noncontrast MRI: comparison with PET study in a canine model.

    Science.gov (United States)

    McCommis, Kyle S; Zhang, Haosen; Herrero, Pilar; Gropler, Robert J; Zheng, Jie

    2008-01-01

    The purpose of this study was to examine the feasibility of quantifying myocardial blood flow (MBF) and rate of myocardial oxygen consumption (MVO(2)) during pharmacologically induced stress without using a contrast agent. The former was measured by the arterial spin labeling (ASL) method and the latter was obtained by measuring the oxygen extraction fraction (OEF) with the magnetic resonance imaging (MRI) blood oxygenation level-dependent effect and Fick's law. The MRI results were compared with the established positron emission tomography (PET) methods. Six mongrel dogs with induced acute moderate left coronary artery stenosis were scanned using a clinical PET and a 1.5-T MRI system, in the same day. Regional MBF, myocardial OEF and MVO(2) were measured with both imaging modalities. Correlation coefficients (R(2)) of the three myocardial indexes (MBF, OEF and MVO(2)) between MRI and PET methods ranged from 0.70 to 0.93. Bland-Altman statistics demonstrated that the estimated precision of the limits of agreement between MRI and PET measurements varied from 18% (OEF) to 37% (MBF) and 45% (MVO(2)). The detected changes in these indexes, at rest and during dobutamine stress, were similar between two image modalities. The proposed noncontrast MRI technique is a promising method to quantitatively assess myocardial perfusion and oxygenation.

  4. Resveratrol preserves myocardial function and perfusion in remote nonischemic myocardium in a swine model of metabolic syndrome.

    Science.gov (United States)

    Robich, Michael P; Chu, Louis M; Burgess, Thomas A; Feng, Jun; Han, Yuchi; Nezafat, Reza; Leber, Michael P; Laham, Roger J; Manning, Warren J; Sellke, Frank W

    2012-11-01

    Resveratrol has been shown to reverse some of the detrimental effects of metabolic syndrome (MetS). We sought to define the impact of supplemental resveratrol on normal myocardium remote from an ischemic territory in a swine model of MetS and chronic myocardial ischemia. Yorkshire swine were fed a normal diet (control), a high cholesterol diet (HCD), or a high cholesterol diet with orally supplemented resveratrol (HCD-R; 100 mg/kg/day). Four weeks after diet modification, myocardial ischemia was induced by ameroid constrictor placement. Seven weeks later, myocardial tissue from a territory remote from the ischemia was harvested. Animals in the HCD and HCD-R groups underwent functional cardiac MRI before ischemia and before sacrifice. Tissue was harvested for protein expression analysis. After 7 weeks of ischemia, regional left ventricular systolic function was significantly increased in HCD-R as compared with HCD animals. During ventricular pacing the HCD group had significantly decreased flow (p = 0.03); perfusion in the HCD-R was preserved as compared with the control. There was no difference in microvascular relaxation. Expression of metabolic proteins Sirt-1 (p = 0.002), AMPkinase (p = 0.02), and carnitine palmitoyltransferase-I (p = 0.002) were upregulated in the HCD-R group. Levels of protein oxidative stress were significantly increased in the HCD and HCD-R groups, as compared with the controls (p = 0.003). Activated endothelial nitric oxide synthase (eNOS) was increased in the HCD-R group (p = 0.01). There was no difference in myocardial endothelial cell density between the groups; however, dividing endothelial cells were decreased in the HCD and HCD-R groups (p = 0.006). Resveratrol supplementation improves regional left ventricular function and preserves perfusion to myocardium remote from an area of ischemia in an animal model of metabolic syndrome and chronic myocardial ischemia. Copyright © 2012 American College of Surgeons. Published by Elsevier Inc

  5. Platelet counts on admission affect coronary flow, myocardial perfusion and left ventricular systolic function after primary percutaneous coronary intervention.

    Science.gov (United States)

    Sharif, Dawod; Abu-Salem, Mira; Sharif-Rasslan, Amal; Rosenschein, Uri

    2017-10-01

    Patients with acute ST-elevation myocardial infarction (STEMI) and increased platelet count treated by fibrinolysis have worse outcomes. The aim of this study was to test the hypothesis that platelet blood count at admission in patients with acute STEMI treated by primary percutaneous coronary intervention affects coronary flow, myocardial perfusion and recovery of left ventricular systolic function. A total of 174 patients presenting with acute anterior STEMI and treated with primary percutaneous coronary intervention were included and divided into subgroups of admission platelet blood count of 400 K. Evaluation of coronary artery flow and myocardial blush grade was performed according to the TIMI criteria. Electrocardiographic ST elevation resolution post-primary percutaneous coronary intervention was evaluated. Doppler echocardiographic evaluation of left anterior descending coronary artery velocities early and late after primary percutaneous coronary intervention and assessment of left ventricular ejection fraction and wall motion score index (WMSI) of left ventricular and left anterior descending coronary artery territory were performed. Post-primary percutaneous coronary intervention TIMI, myocardial blush grade and ST elevation resolution were similar in all groups. Patients with platelet counts primary percutaneous coronary intervention, and higher prevalence of left anterior descending coronary artery velocity deceleration time exceeding 600 ms, (45.5% vs. 40%, P400 K presented with worse left ventricular ejection fraction, left ventricular WMSI and left anterior descending coronary artery WMSI, and before discharge this subgroup had worse left ventricular WMSI and left anterior descending coronary artery WMSI, Pprimary percutaneous coronary intervention with lower admission platelet count had higher left anterior descending coronary artery diastolic velocities, better myocardial perfusion with more patients having left anterior descending coronary artery

  6. Intracoronary Administration of Allogeneic Adipose Tissue-Derived Mesenchymal Stem Cells Improves Myocardial Perfusion But Not Left Ventricle Function, in a Translational Model of Acute Myocardial Infarction.

    Science.gov (United States)

    Bobi, Joaquim; Solanes, Núria; Fernández-Jiménez, Rodrigo; Galán-Arriola, Carlos; Dantas, Ana Paula; Fernández-Friera, Leticia; Gálvez-Montón, Carolina; Rigol-Monzó, Elisabet; Agüero, Jaume; Ramírez, José; Roqué, Mercè; Bayés-Genís, Antoni; Sánchez-González, Javier; García-Álvarez, Ana; Sabaté, Manel; Roura, Santiago; Ibáñez, Borja; Rigol, Montserrat

    2017-05-03

    Autologous adipose tissue-derived mesenchymal stem cells (ATMSCs) therapy is a promising strategy to improve post-myocardial infarction outcomes. In a porcine model of acute myocardial infarction, we studied the long-term effects and the mechanisms involved in allogeneic ATMSCs administration on myocardial performance. Thirty-eight pigs underwent 50 minutes of coronary occlusion; the study was completed in 33 pigs. After reperfusion, allogeneic ATMSCs or culture medium (vehicle) were intracoronarily administered. Follow-ups were performed at short (2 days after acute myocardial infarction vehicle-treated, n=10; ATMSCs-treated, n=9) or long term (60 days after acute myocardial infarction vehicle-treated, n=7; ATMSCs-treated, n=7). At short term, infarcted myocardium analysis showed reduced apoptosis in the ATMSCs-treated animals (48.6±6% versus 55.9±5.7% in vehicle; P =0.017); enhancement of the reparative process with up-regulated vascular endothelial growth factor, granulocyte macrophage colony-stimulating factor, and stromal-derived factor-1α gene expression; and increased M2 macrophages (67.2±10% versus 54.7±10.2% in vehicle; P =0.016). In long-term groups, increase in myocardial perfusion at the anterior infarct border was observed both on day-7 and day-60 cardiac magnetic resonance studies in ATMSCs-treated animals, compared to vehicle (87.9±28.7 versus 57.4±17.7 mL/min per gram at 7 days; P =0.034 and 99±22.6 versus 43.3±14.7 22.6 mL/min per gram at 60 days; P =0.0001, respectively). At day 60, higher vascular density was detected at the border zone in the ATMSCs-treated animals (118±18 versus 92.4±24.3 vessels/mm 2 in vehicle; P =0.045). Cardiac magnetic resonance-measured left ventricular ejection fraction of left ventricular volumes was not different between groups at any time point. In this porcine acute myocardial infarction model, allogeneic ATMSCs-based therapy was associated with increased cardioprotective and reparative

  7. Myocardial perfusion scintigraphy in identification and localization of individual coronary lesions

    Directory of Open Access Journals (Sweden)

    Baškot Branislav

    2004-01-01

    Full Text Available The aim of this study was to evaluate the accuracy of myocardial perfusion scintigraphy with technetium-99m tetrofosmin by single-photon emission computed tomography (SPECT, using one-day protocol in the identification and localization of individual stenosed coronary vessels. Sixty-eight patients with suspected coronary artery disease (CAD were studied. In thirty of them coronary angiography showed significant stenosis (³50%. Nine patients were with one-vessel disease, 11 were with two-vessel disease, and 10 were with three-vessel disease. All the patients were administered two i.v. injections of 99mTc tetrofosmin, one at peak pharmacologic exercise (1-3 min after i.v. administration of dipiridamol 0.56 mg per kg during 4 min 370 MBq, and the other 740 MBq at rest 3 hrs after the exercise test (acquisition was obtained 15-30 min after injections for both studies. Overall sensitivity, specificity, and diagnostic accuracy in the identification of individual stenosed coronary vessels were 90%, 86%, and 88%, respectively. Sensitivity, specificity, and accuracy in each of the individual vascular territories were not significantly different: LAD (96% 64%, and 75%, ACx (73%, 100%, and 94%, RCA (95%, 93%, and 94%. The results of this study demonstrated one-day 99mTc-tetrofosmin SPECT scintigraphy to be suitable and accurate technique for the identification and localization of individual stenosed coronary vessels, as well as a highly sensitive method in the recognition of one- and multiple-vessel diseases of coronary arteries.

  8. Enhancement of dynamic myocardial perfusion PET images based on low-rank plus sparse decomposition.

    Science.gov (United States)

    Lu, Lijun; Ma, Xiaomian; Mohy-Ud-Din, Hassan; Ma, Jianhua; Feng, Qianjin; Rahmim, Arman; Chen, Wufan

    2018-02-01

    The absolute quantification of dynamic myocardial perfusion (MP) PET imaging is challenged by the limited spatial resolution of individual frame images due to division of the data into shorter frames. This study aims to develop a method for restoration and enhancement of dynamic PET images. We propose that the image restoration model should be based on multiple constraints rather than a single constraint, given the fact that the image characteristic is hardly described by a single constraint alone. At the same time, it may be possible, but not optimal, to regularize the image with multiple constraints simultaneously. Fortunately, MP PET images can be decomposed into a superposition of background vs. dynamic components via low-rank plus sparse (L + S) decomposition. Thus, we propose an L + S decomposition based MP PET image restoration model and express it as a convex optimization problem. An iterative soft thresholding algorithm was developed to solve the problem. Using realistic dynamic 82Rb MP PET scan data, we optimized and compared its performance with other restoration methods. The proposed method resulted in substantial visual as well as quantitative accuracy improvements in terms of noise versus bias performance, as demonstrated in extensive 82Rb MP PET simulations. In particular, the myocardium defect in the MP PET images had improved visual as well as contrast versus noise tradeoff. The proposed algorithm was also applied on an 8-min clinical cardiac 82Rb MP PET study performed on the GE Discovery PET/CT, and demonstrated improved quantitative accuracy (CNR and SNR) compared to other algorithms. The proposed method is effective for restoration and enhancement of dynamic PET images. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Prevalence of Ischemia on Myocardial Perfusion Scintigraphy of Pre- and Postmenopausal Women

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Daniel Augusto Message dos, E-mail: danielmessage@cardiol.br; Navarro, Wendy Yasdin Sierraalta; Alexandre, Leonardo Machado; Cestari, Priscila Feitosa; Smanio, Paola Emanuela Poggio [Instituto Dante Pazzanese de Cardiologia, São Paulo, SP (Brazil)

    2013-12-15

    In postmenopausal women, the presence of risk factors for coronary artery disease (CAD) increases. However, the difference in prevalence of ischemia between pre- and postmenopausal women with multiple risk factors for CAD has not been well established. To compare the prevalence of ischemia on Tc{sup 99m}-sestamibi myocardial perfusion scintigraphy (MPS) in pre-and postmenopausal women, and to evaluate whether menopause can be considered an independent risk predictor of ischemia in women with multiple risk factors for CAD. This study retrospectively assessed 500 MPS of pre- and postmenopausal women with multiple risk factors for CAD. Statistical analysis was performed by using Fisher exact test and univariate and multivariate analysis, a p value ≤ 0.05 being considered significant. Postmenopausal women represented 55.9% of the sample; 83.3% were hypertensive; 28.9%, diabetic; 32.1%, smokers; 25%, obese; 61.2% had high cholesterol levels; and 34.3% had known CAD. Postmenopausal women were more often hypertensive, diabetic and dyslipidemic, and had lower functional capacity on exercise testing (p = < 0.005). The presence of ischemia on MPS did not significantly differ between the pre- and postmenopausal groups (p = 0.395). The only variable associated with ischemia on MPS was known CAD (p = 0.004). The results suggest that, in women with multiple risk factors for CAD, menopause was not an independent predictor of ischemia on MPS. Those data support the idea that the investigation of ischemia via MPS in women with multiple risk factors for CAD should begin prior to menopause.

  10. Coronary grafts flow and cardiac pacing modalities: how to improve perioperative myocardial perfusion.

    LENUS (Irish Health Repository)

    D'Ancona, Giuseppe

    2012-02-03

    OBJECTIVE: Aim of this study was to investigate modifications of coronary grafts flow during different pacing modalities after CABG. MATERIALS AND METHODS: Two separate prospective studies were conducted in patients undergoing CABG and requiring intraoperative epicardial pacing. In a first study (22 patients) coronary grafts flows were measured during dual chamber pacing (DDD) and during ventricular pacing (VVI). In a second study (10 patients) flows were measured during DDD pacing at different atrio-ventricular (A-V) delay periods. A-V delay was adjusted in 25 ms increments from 25 to 250 ms and flow measurements were performed for each A-V delay increment. A transit time flowmeter was used for the measurements. RESULTS: An average of 3.4 grafts\\/patient were performed. In the first study, average coronary graft flow was 47.4+\\/-20.8 ml\\/min during DDD pacing and 41.8+\\/-18.2 ml\\/min during VVI pacing (P = 0.0004). Furthermore average systolic pressure was 94.3+\\/-10.1 mmHg during DDD pacing and 89.6+\\/-12.2 mmHg during VVV pacing (P = 0.0007). No significant differences in diastolic pressure were recorded during the two different pacing modalities. In the second study, maximal flows were achieved during DDD pacing with an A-V delay of 175 ms (54+\\/-9.6 ml\\/min) and minimal flows were detected at 25 ms A-V delay (38.1+\\/-4.7 ml\\/min) (P=ns). No significant differences in systolic or diastolic blood pressure were noticed during the different A-V delays. CONCLUSION: Grafts flowmetry provides an extra tool to direct supportive measures such as cardiac pacing after CABG. DDD mode with A-V delay around 175 ms. should be preferred to allow for maximal myocardial perfusion via the grafts.

  11. Myocardial perfusion imaging laboratory efficiency with the use of regadenoson compared to adenosine and dipyridamole.

    Science.gov (United States)

    Friedman, Michelle; Spalding, James; Kothari, Smita; Wu, You; Gatt, Elyse; Boulanger, Luke

    2013-01-01

    Adenosine, dipyridamole, and regadenoson are pharmacologic stress agents used in myocardial perfusion imaging (MPI), to diagnose and monitor coronary artery disease. Clinical studies suggest that regadenoson has pharmacologic properties that simplify the MPI procedure through availability to a wider range of patients and easier administrative requirements. This study assesses the operational advantages and laboratory efficiency associated with the use of regadenoson compared to adenosine and dipyridamole. A web-based survey of 141 nuclear medicine technologists working in US-based cardiovascular imaging laboratories from June-July 2009. Descriptive statistics measured the adenosine, dipyridamole, and regadenoson cohorts. Bivariate analyses compared the overall and staff-specific time to conduct an MPI test. The site-specific sub-groups were defined by hospital vs non-hospital setting, hours of operation, number of SPECT cameras, and number of full-time equivalent staff, including nurses, nuclear technologists, physicians, and nurse practitioners/physician assistants. The total time to conduct an MPI test was shortest with regadenoson 156 (46) min compared to adenosine and dipyridamole 182 (63) and 191 (61) min, respectively. Time from regadenoson administration to the start of the imaging session, including dose calculation and infusion time, was 14.2 min less than adenosine, and 12.0 min less than dipyridamole. The time to manage adverse events was shortest if it occurred with regadenoson compared to adenosine and dipyridamole, with minor exceptions. Due to the nature of survey implementation, possible recall bias may limit the results. Some differences in procedures times may be attributable to differences in laboratories' protocols. Overall time savings and time savings stratified by operational ability (number of staff, number of SPECT cameras, hours of operation) translate to a more efficient utilization of laboratory resources when using regadenoson

  12. Myocardial perfusion scintigraphy in the UK: insights from the British Nuclear Cardiology Society Survey 2000.

    Science.gov (United States)

    Kelion, A D; Anagnostopoulos, C; Harbinson, M; Underwood, S R; Metcalfe, M

    2005-09-01

    The National Institute for Health and Clinical Excellence (NICE) has recently published a very positive technology appraisal of myocardial perfusion scintigraphy (MPS). This has important implications for service provision within the National Health Service, and an accurate knowledge of the current level of MPS activity is necessary. A postal questionnaire was sent to 207 nuclear medicine departments in the UK, requesting information about nuclear cardiology facilities, activity, and practice. Non-responding departments were sent a second questionnaire, followed where necessary by a telephone call. A response rate of 61% was achieved; 52% of departments performed MPS, and these tended to have more gamma cameras than those which did not (median (25th-75th centile) 2.0, 1.5-2.5 v 1.0, 0.5-1.5; p = 0.02). The median number of studies performed was 256 (144-460). The estimated rate of MPS in the UK for the year 2000 was 1200 per million population. The median (25th-75th centile) waiting time for MPS was 16 (9-24) weeks. Pharmacological stress was used in 77% of studies, and a technetium-99m based radiopharmaceutical in 60% (two day protocol in 75%). Tomographic rather than planar imaging was performed in 88% of studies, of which 22% were ECG gated. A cardiologist was involved in reporting in 35% of studies. MPS activity in the UK remains low, and it tends to be provided as a low volume service with unacceptably long waiting times and a lack of involvement by cardiologists. The recent NICE appraisal may provide an impetus for further resourcing and development.

  13. Adenosine stress high-pitch 128-slice dual-source myocardial computed tomography perfusion for imaging of reversible myocardial ischemia: comparison with magnetic resonance imaging.

    Science.gov (United States)

    Feuchtner, Gudrun; Goetti, Robert; Plass, André; Wieser, Monika; Scheffel, Hans; Wyss, Christophe; Stolzmann, Paul; Donati, Olivio; Schnabl, Johannes; Falk, Volkmar; Alkadhi, Hatem; Leschka, Sebastian; Cury, Ricardo C

    2011-09-01

    Coronary computed tomography angiography (CTA) enables accurate anatomic evaluation of coronary artery stenosis but lacks information about hemodynamic significance. The aim of this study was to evaluate 128-slice myocardial CT perfusion (CTP) imaging with adenosine stress using a high-pitch mode, in comparison with cardiac MRI (CMR). Thirty-nine patients with intermediate to high coronary risk profile underwent adenosine stress 128-slice dual source CTP (128×0.6 mm, 0.28 seconds). Among those, 30 patients (64 ± 10 years, 6% women) also underwent adenosine stress CMR (1.5T). The 2-step CTP protocol consisted of (1) adenosine stress-CTP using a high-pitch factor (3.4) ECG-synchronized spiral mode and (2) rest-CTP/coronary-CTA using either high-pitch (heart rate 63 bpm). Results were compared with CMR and with invasive angiography in 25 patients. The performance of stress-CTP for detection of myocardial perfusion defects compared with CMR was sensitivity, 96%; specificity, 88%; positive predictive value (PPV), 93%; negative predictive value (NPV), 94% (per vessel); and sensitivity, 78%; specificity, 87%; PPV, 83%; NPV, 84% (per segment). The accuracy of stress-CTP for imaging of reversible ischemia compared with CMR was sensitivity, 95%; specificity, 96%; PPV, 95%; and NPV, 96% (per vessel). In 25 patients who underwent invasive angiography, the accuracy of CTA for detection of stenosis >70% was (per segment): sensitivity, 96%; specificity, 88%; PPV, 67%; and NPV, 98.9%. The accuracy improved from 84% to 95% after adding stress CTP to CTA. Radiation exposure of the entire stress/rest CT protocol was only 2.5 mSv. Adenosine-induced stress 128-slice dual-source high-pitch myocardial CTP allows for simultaneously assessment of reversible myocardial ischemia and coronary stenosis, with good diagnostic accuracy as compared with CMR and invasive angiography, at a very low radiation exposure.

  14. Type 2 diabetes mellitus correlates with systolic function during myocardial stress perfusion scanning with Nitrogen-13 ammonia PET.

    Science.gov (United States)

    Juárez-Orozco, Luis Eduardo; van der Zant, Friso M; Slart, Riemer H J A; Lazarenko, Sergiy V; Alexanderson, Erick; Tio, Rene A; Knol, Remco J J

    2017-08-01

    The influence of type 2 diabetes mellitus (DM2) on systolic function is partially determined by the coronary vasodilator function, nevertheless, an independent effect is suspected. We evaluated the relationship between DM2 and systolic function considering PET quantitative myocardial perfusion. We analyzed 585 patients without a previous myocardial infarction referred to a rest and adenosine stress Nitrogen-13 ammonia PET. A bootstrapped multiple linear regression analysis was performed using DM2, stress myocardial blood flow (sMBF), myocardial perfusion reserve (MPR), and clinical risk factors as predictors and LVEF as the outcome variable; an interaction term was additionally investigated. Two hundred and ninety male and 295 female patients (mean age 65.3 ± 9.9 and 67.4 ± 10 years, respectively) were included. 57.1% presented hypertension, 16% smoking, 37.6% hypercholesterolemia, 33.8% family history for CAD, and 15.2% DM2. The mean MPR was 2.13 ± 0.48 and 2.21 ± 0.60, mean sMBF was 2.01 ± 0.51 and 2.15 ± 0.54, and mean LVEF was 63% ± 10.4 and 67% ± 10.1 for diabetics and non-diabetics, respectively. A significant relation was detected for sMBF (B = 5.830 95% CI [3.505, 9.549], P = .001) and DM2 (B = -2.599 95% CI [-5.125, -0.119], P = .03) with LVEF. The interaction (DM2 × sMBF) yielded no significance (P = .512). DM2 influences PET-measured systolic function in patients without previous myocardial infarction independently from myocardial perfusion parameters. Our study supports the importance of DM2 as an independent risk factor for deteriorating systolic function.

  15. Detection of obstructive coronary artery disease using regadenoson stress and 82Rb PET/CT myocardial perfusion imaging.

    Science.gov (United States)

    Hsiao, Edward; Ali, Bilal; Blankstein, Ron; Skali, Hicham; Ali, Towhid; Bruyere, John; Kwong, Raymond Y; Di Carli, Marcelo F; Dorbala, Sharmila

    2013-10-01

    Our objective was to study the diagnostic performance of regadenoson (82)Rb myocardial perfusion PET imaging to detect obstructive coronary artery disease (CAD). We studied 134 patients (mean age, 63 ± 12 y; mean body mass index, 31 ± 9 kg/m(2)) without known CAD (96 with coronary angiography and 38 with low pretest likelihood of CAD). Stress left ventricular ejection fraction (LVEF) minus rest LVEF defined LVEF reserve. The Duke score was used to estimate the anatomic extent of jeopardized myocardium. Regadenoson PET had a high sensitivity, 92% (95% confidence interval [CI], 83%-97%), in detecting obstructive CAD, with a normalcy rate of 97% (95% CI, 86%-99%), specificity of 77% (54/70 patients; 95% CI, 66%-86%), and area under the receiver-operator-characteristic curve of 0.847 (95% CI, 0.774-0.903; P Regadenoson PET demonstrated high sensitivity to detect CAD in patients with single-vessel CAD (89%; 95% CI, 70%-98%). The mean LVEF reserve was significantly higher in patients with normal myocardial perfusion imaging results (6.5% ± 5.4%) than in those with mild (4.3 ± 5.1, P = 0.03) and moderate to severe reversible defects (-0.2% ± 8.4%, P = 0.001). Also, mean LVEF reserve was significantly higher in patients with a low likelihood of CAD (7.2% ± 4.5%, P Regadenoson (82)Rb myocardial perfusion imaging is accurate for the detection of obstructive CAD. LVEF reserve is high in patients without significant ischemia or significant angiographic jeopardized myocardium.

  16. Usefulness of combination post-stress dysfunction and perfusion imaging in technetium-99m-tetrofosmin myocardial scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Yamazaki, Yoko; Imai, Kamon; Konaka, Ryohei; Nakajima, Takatomo; Goto, Sayaka; Horie, Toshinobu [Saitama Cardiovascular and Respiratory Center, Konan (Japan); Saito, Satoshi; Ozawa, Yukio; Kanmatsuse, Katsuo

    2001-09-01

    Myocardial perfusion imaging has lower sensitivity for the diagnosis of coronary artery disease in patients with three-vessel disease. The presence of post-stress dysfunction of the left ventricle, evaluated by electrocardiography (ECG) gated single photon emission computed tomography (SPECT) with a quantitative gated SPECT program, was investigated in patients with coronary artery disease, and also whether combining post-stress dysfunction and myocardial perfusion imaging improved the diagnosis of coronary artery disease. ECG gated technetium-99m-tetrofosmin SPECT was performed using a one day, stress and rest, protocol in 139 patients. SPECT and coronary angiography were performed within 1 month. The coronary artery disease group consisted of 89 patients: 43 with one-vessel disease (1VD), 28 with two-vessel disease (2VD), and 18 with three-vessel disease (3VD). The group with zero-vessel disease (0VD) consisted of 50 patients. According to post-stress and rest ejection fraction (EF) and end-systolic volume (ESV), post-stress dysfunction is defined as follows: rest EF - post-stress EF{>=}5% and post-stress ESV - rest ESV{>=}5ml. In the coronary artery disease group, post-stress ESV was larger than rest ESV (37.8{+-}26.4, 34.0{+-}24.2 ml, p<0.001), and post-stress EF was lower than rest EF (61.5{+-}11.1%, 64.2{+-}10.8%, p<0.001). In the 0VD group, ESV and EF were the same for post-stress and rest (25.7{+-}20.8, 26.2{+-}21.6 ml, NS; 70.4{+-}9.5%, 70.0{+-}9.6%, NS). Post-stress dysfunction was 6.0% in the 0VD group and 30.3% in the coronary artery disease group (p<0.001). Furthermore, post-stress dysfunction in the 2VD (35.7%) and 3VD (38.9%) groups was higher than that in the 0VD group (p<0.01, p<0.01). Sensitivity of coronary artery disease diagnosis by myocardial perfusion imaging was 75%. The combination of post-stress dysfunction and myocardial perfusion imaging improved sensitivity from 75% to 82% (p<0.05), but reduced the specificity from 92% to 86% (p=0

  17. The reproducibility and prognostic value of serial measurements of heart rate response to regadenoson during myocardial perfusion imaging.

    Science.gov (United States)

    Andrikopoulou, Efstathia; AlJaroudi, Wael A; Farag, Ayman; Lester, Davis; Patel, Hiren; Iskandrian, Ami E; Hage, Fadi G

    2016-07-01

    The heart rate response (HRR, percentage change from baseline) to regadenoson during myocardial perfusion imaging (MPI) can provide incremental prognostic value in patients with known or suspected coronary artery disease. Our purpose was to evaluate the variability and prognostic value of HRR on serial measurements. We studied 648 consecutive patients (61 ± 11 years, 48 % with diabetes) who underwent two regadenoson MPI studies (16 ± 9 months between studies). HRR regadenoson on serial measurements without systematic or proportional biases. Patients with consistently normal HRR had the best prognosis.

  18. Prediction of clinical outcome by myocardial CT perfusion in patients with low-risk unstable angina pectoris

    DEFF Research Database (Denmark)

    Linde, Jesper J; Sørgaard, Mathias; Kühl, Jørgen T

    2017-01-01

    The prognostic implications of myocardial computed tomography perfusion (CTP) analyses are unknown. In this sub-study to the CATCH-trial we evaluate the ability of adenosine stress CTP findings to predict mid-term major adverse cardiac events (MACE). In 240 patients with acute-onset chest pain, yet...... %) suffered a MACE (cardiac death, non-fatal myocardial infarction and revascularizations). Accuracy for the prediction of MACE expressed as the area under curve (AUC) on receiver-operating characteristic curves was 0.88 (0.83-0.92) for visual assessment of a PD and 0.80 (0.73-0.85) for stress TPR (transmural.......98-0.99) for stress TPR, p 10 % of the LV myocardium had a worse prognosis compared to patients with a PD covering sensitivity 84...

  19. Stress myocardial perfusion imaging by CMR provides strong prognostic value to cardiac events regardless of patient's sex.

    Science.gov (United States)

    Coelho-Filho, Otavio R; Seabra, Luciana F; Mongeon, François-Pierre; Abdullah, Shuaib M; Francis, Sanjeev A; Blankstein, Ron; Di Carli, Marcelo F; Jerosch-Herold, Michael; Kwong, Raymond Y

    2011-08-01

    The major aim of this study is to test the hypothesis that stress cardiac magnetic resonance (CMR) imaging can provide robust prognostic value in women presenting with suspected ischemia, to the same extent as in men. Compelling evidence indicates that women with coronary artery disease (CAD) experience worse outcomes than men owing to a lack of early diagnosis and management. Numerous clinical studies have shown that stress CMR detects evidence of myocardial ischemia and infarction at high accuracy. Compared to nuclear scintigraphy, CMR is free of ionizing radiation, has high spatial resolution for imaging small hearts, and overcomes breast attenuation artifacts, which are substantial advantages when imaging women for CAD. We performed stress CMR in 405 patients (168 women, mean age 58 ± 14 years) referred for ischemia assessment. CMR techniques included cine cardiac function, perfusion imaging during vasodilating stress, and late gadolinium enhancement imaging. All patients were followed for major adverse cardiac events (MACE). At a median follow-up of 30 months, MACE occurred in 36 patients (9%) including 21 cardiac deaths and 15 acute myocardial infarctions. In women, CMR evidence of ischemia (ISCHEMIA) demonstrated strong association with MACE (unadjusted hazard ratio: 49.9, p women with ISCHEMIA(+) had an annual MACE rate of 15%, women with ISCHEMIA(-) had very low annual MACE rate (0.3%), which was not statistically different from the low annual MACE rate in men with ISCHEMIA(-) (1.1%). CMR myocardial ischemia score was the strongest multivariable predictor of MACE in this cohort, for both women and men, indicating robust cardiac prognostication regardless of sex. In addition to avoiding exposure to ionizing radiation, stress CMR myocardial perfusion imaging is an effective and robust risk-stratifying tool for patients of either sex presenting with possible ischemia. Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All

  20. The effect of CT-based attenuation correction on the automatic perfusion score of myocardial perfusion imaging using a dedicated cardiac solid-state CZT SPECT/CT.

    Science.gov (United States)

    Kennedy, John A; Brodov, Yafim; Weinstein, Adam L; Israel, Ora; Frenkel, Alex

    2017-05-01

    Data regarding cardiac cadmium-zinc-telluride (CZT)-specific augmented databases and their impact on CT-based attenuation correction (AC) perfusion scores in myocardial perfusion imaging (MPI) were obtained on a multiple-pinhole CZT SPECT/CT. Summed stress (SSS) and rest scores (SRS) were measured using automated software in three independent patient groups: group 1 (n = 80) underwent MPI on both CZT and conventional sodium iodide (NaI) devices, group 2 (n = 80) with low coronary artery disease likelihood and normal MPI provided reference CZT databases; and group 3 (n = 152) served to compare AC and non-AC (NAC) scores on CZT. Group 1 CZT and NaI scores gave a significant 1:1 linear correlation for CZT scores referenced to the custom database vs NaI scores referenced to the default database, but these were not concordant when CZT scores were referenced to the default database. AC significantly decreased average SSS and SRS in men vs NAC, 4.29 ± 6.30 vs 5.37 ± 7.26 (P < 0.001) and 2.37 ± 4.72 vs 3.13 ± 5.85 (P < 0.001), but not in women, 2.28 ± 3.42 vs 2.28 ± 3.08 (p NS) and 0.46 ± 1.51 vs 0.61 ± 1.86, (p NS), respectively. Specifically designed databases for solid-state CZT cardiac SPECT provide accurate quantitation of perfusion scores concordant with those previously validated for conventional SPECT. AC and NAC CZT scores differed significantly, especially in men.

  1. Regional myocardial perfusion defects during exercise, as assessed by three dimensional integration of morphology and function, in relation to abnormal endothelium dependent vasoreactivity of the coronary microcirculation

    Science.gov (United States)

    Schindler, T H; Nitzsche, E; Magosaki, N; Brink, I; Mix, M; Olschewski, M; Solzbach, U; Just, H

    2003-01-01

    Objective: To test the hypothesis that scintigraphic regional myocardial perfusion defects during exercise in patients with normal coronary angiography may be related to abnormal endothelium dependent vasoreactivity of the corresponding myocardial territory in response to cold pressor testing. Methods: 38 patients were classified into two groups according to the presence or absence of exercise induced scintigraphic myocardial perfusion defects. A cold pressor test was done in all patients during routine coronary angiography, followed by dynamic positron emission tomography to establish coronary blood flow mediated vasoreactivity of the epicardial coronary artery and the myocardial territories supplied by the left anterior descending, left circumflex, and right coronary arteries. Results: 28 patients had regional myocardial perfusion defects while 10 had normal scintigraphic imaging. The three dimensional scintigraphic fusion image revealed 49 regional myocardial perfusion defects with a mean (SD) reversibility of the original stress defect of 20 (3)%. In patients with exercise induced regional myocardial perfusion defects, the responses of epicardial luminal area and regional myocardial blood flow (RMBF) to cold pressor testing were reduced compared with patients with normal perfusion imaging (epicardial luminal area: 5.2 (1.2) to 4.2 (0.86) mm2 v 4.7 (0.5) to 5.8 (0.5) mm2; RMBF: 0.75 (0.16) to 0.78 (0.20) ml/g/min v 0.75 (0.15) to 1.38 (0.26) ml/g/min; p ≤ 0.03, respectively). In patients with regional abnormal scintigraphic perfusion, the corresponding RMBF response to cold pressor testing was more severely impaired than the mean myocardial blood flow in the remaining two vascular territories, but the difference was not significant (0.75 (0.16) to 0.78 (0.20) ml/g/min v 0.75 (0.10) to 0.87 (0.12) ml/g/min; NS). The endothelium independent increase in RMBF induced by glyceryl trinitrate did not differ between patients with exercise induced myocardial perfusion

  2. Comparison of 18F-Labeled Fluoroalkylphosphonium Cations with 13N-NH3 for PET Myocardial Perfusion Imaging.

    Science.gov (United States)

    Kim, Dong-Yeon; Kim, Hyeon Sik; Reder, Sybille; Zheng, Jin Hai; Herz, Michael; Higuchi, Takahiro; Pyo, A Young; Bom, Hee-Seung; Schwaiger, Markus; Min, Jung-Joon

    2015-10-01

    Despite substantial advances in the diagnosis of cardiovascular disease, there is a need for 18F-labeled myocardial perfusion agents for the diagnosis of ischemic heart disease because current PET tracers for myocardial perfusion imaging have a short half-life that limits their widespread clinical use in PET. Thus, 18F-labeled fluoroalkylphosphonium derivatives (18F-FATPs), including (5-18F-fluoropentyl)triphenylphosphonium cation (18F-FPTP), (6-18F-fluorohexyl)triphenylphosphonium cation (18F-FHTP), and (2-(2-18F-fluoroethoxy)ethyl)triphenylphosphonium cation (18F-FETP), were synthesized. The myocardial extraction and image quality of the 18F-FATPs were compared with those of 13N-NH3 in rat models. The first-pass extraction fraction (EF) values of the 18F-FATPs (18F-FPTP, 18F-FHTP, 18F-FETP) and 13N-NH3 were measured in isolated rat hearts perfused with the Langendorff method (flow velocities, 0.5, 4.0, 8.0, and 16.0 mL/min). Normal and myocardial infarction rats were imaged with small-animal PET after intravenous injection of 37 MBq of 18F-FATPs and 13N-NH3. To determine pharmacokinetics, a region of interest was drawn around the heart, and time-activity curves of the 18F-FATPs and 13N-NH3 were generated to obtain the counts per pixel per second. Defect size was analyzed on the basis of polar map images of 18F-FATPs and 13N-NH3. The EF values of 18F-FATPs and 13N-NH3 were comparable at low flow velocity (0.5 mL/min), whereas at higher flows EF values of 18F-FATPs were significantly higher than those of 13N-NH3 (4.0, 8.0, and 16.0 mL/min, PNH3 were 2.10±0.30, 4.36±0.20, 3.88±1.03, and 0.70±0.09, respectively, 10 min after injection, whereas myocardium-to-lung ratios were 5.00±0.25, 4.33±0.20, 7.98±1.23, and 2.26±0.14, respectively. Although 18F-FATPs and 13N-NH3 sharply delineated myocardial perfusion defects, defect size on the 13N-NH3 images was significantly smaller than on the 18F-FATP images soon after tracer injection (0-10 min, P=0.027). 18F

  3. Feasibility of one-eighth time gated myocardial perfusion SPECT functional imaging using IQ-SPECT.

    Science.gov (United States)

    Caobelli, Federico; Thackeray, James T; Soffientini, Alberto; Bengel, Frank M; Pizzocaro, Claudio; Guerra, Ugo Paolo

    2015-11-01

    IQ-SPECT, an add-on to general purpose cameras based on multifocal collimation, can reduce myocardial perfusion imaging (MPI) acquisition times to one-fourth that of standard procedures (to 12 s/view). In a phantom study, a reduction of the acquisition time to one-eighth of the standard time (to 6 s/view) was demonstrated as feasible. It remains unclear whether such a reduction could be extended to clinical practice. Fifty patients with suspected or diagnosed CAD underwent a 2-day stress-rest (99m)Tc-sestamibi MPI protocol. Two consecutive SPECT acquisitions (6 and 12 s/view) were performed. Electrocardiogram-gated images were reconstructed with and without attenuation correction (AC). Polar maps were generated and visually scored by two blinded observers for image quality and perfusion in 17 segments. Global and regional summed stress score (SSS), summed rest score (SRS) and summed difference score (SDS) were determined. Left ventricular volumes and ejection fraction were calculated based on automated contour detection. Image quality was scored higher with the 12 s/view acquisition, both with and without AC. Summed scores were statistically comparable between the 6 s/view and the 12 s/view acquisition, both globally and in individual coronary territories (e.g. in images with AC, SSS were 6.6 ± 8.3 and 6.2 ± 8.2 with 6 s and 12 s/view, respectively, p = 0.10; SRS were 3.9 ± 5.6 and 3.5 ± 5.3, respectively, p = 0.19; and SDS were 2.8 ± 5.7 and 2.6 ± 5.7, respectively, p = 0.59). Both acquisitions allowed MPI-based diagnosis of CAD in 25 of the 50 patients (with AC). Calculated end-diastolic volume (EDV) and end-systolic volume (ESV) were modestly higher with the 6 s/view acquisition than with the 12 s/view acquisition (EDV +4.8 ml at rest and +3.7 ml after stress, p = 0.003; ESV +4.1 ml at rest and +2.6 ml after stress, p = 0.01), whereas the ejection fraction did not differ (-1.2 % at rest, p = 0.20, and -0

  4. Quantification of myocardial perfusion using cardiac magnetic resonance imaging correlates significantly to rubidium-82 positron emission tomography in patients with severe coronary artery disease: A preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Qayyum, Abbas A., E-mail: abbas.ali.qayyum@regionh.dk [Department of Cardiology and Cardiac Catheterization Laboratory 2014, The Heart Centre, Rigshospitalet, University Hospital of Copenhagen and Faculty of Health Sciences, Copenhagen University, Blegdamsvej 9, 2100 Copenhagen (Denmark); Hasbak, Philip, E-mail: philip.hasbak@regionh.dk [Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, University Hospital of Copenhagen and Faculty of Health Sciences, Copenhagen University, Blegdamsvej 9, 2100 Copenhagen (Denmark); Larsson, Henrik B.W., E-mail: henrik.larsson@regionh.dk [Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, University Hospital of Copenhagen and Faculty of Health Sciences, Copenhagen University, Blegdamsvej 9, 2100 Copenhagen (Denmark); Functional Imaging Unit, Diagnostic Department, Glostrup Hospital, University Hospital of Copenhagen and Faculty of Health Sciences, Copenhagen University, Ndr. Ringvej 57, 2600 Copenhagen (Denmark); Christensen, Thomas E., E-mail: thomas.emil.christensen@regionh.dk [Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, University Hospital of Copenhagen and Faculty of Health Sciences, Copenhagen University, Blegdamsvej 9, 2100 Copenhagen (Denmark); Ghotbi, Adam A., E-mail: adam.ali.ghotbi@regionh.dk [Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, University Hospital of Copenhagen and Faculty of Health Sciences, Copenhagen University, Blegdamsvej 9, 2100 Copenhagen (Denmark); Mathiasen, Anders B., E-mail: anders.b.mathiasen@gmail.com [Department of Cardiology and Cardiac Catheterization Laboratory 2014, The Heart Centre, Rigshospitalet, University Hospital of Copenhagen and Faculty of Health Sciences, Copenhagen University, Blegdamsvej 9, 2100 Copenhagen (Denmark); and others

    2014-07-15

    Introduction: Aim was to compare absolute myocardial perfusion using cardiac magnetic resonance imaging (CMRI) based on Tikhonov's procedure of deconvolution and rubidium-82 positron emission tomography (Rb-82 PET). Materials and methods: Fourteen patients with coronary artery stenosis underwent rest and adenosine stress imaging by 1.5-Tesla MR Scanner and a mCT/PET 64-slice Scanner. CMRI were analyzed based on Tikhonov's procedure of deconvolution without specifying an explicit compartment model using our own software. PET images were analyzed using standard clinical software. CMRI and PET data was compared with Spearman's rho and Bland–Altman analysis. Results: CMRI results were strongly and significantly correlated with PET results for the absolute global myocardial perfusion differences (r = 0.805, p = 0.001) and for global myocardial perfusion reserve (MPR) (r = 0.886, p < 0.001). At vessel territorial level, CMRI results were also significantly correlated with absolute PET myocardial perfusion differences (r = 0.737, p < 0.001) and MPR (r = 0.818, p < 0.001). Each vessel territory had similar strong correlation for absolute myocardial perfusion differences (right coronary artery (RCA): r = 0.787, p = 0.001; left anterior descending artery (LAD): r = 0.796, p = 0.001; left circumflex artery (LCX): r = 0.880, p < 0.001) and for MPR (RCA: r = 0.895, p < 0.001; LAD: r = 0.886, p < 0.001; LCX: r = 0.886, p < 0.001). Conclusion: On a global and vessel territorial basis, CMRI-measured absolute myocardial perfusion differences and MPR were strongly and significantly correlated with the Rb-82 PET findings.

  5. Impact of integrating heart rate response with perfusion imaging on the prognostic value of regadenoson SPECT myocardial perfusion imaging in patients with end-stage renal disease.

    Science.gov (United States)

    Gomez, Javier; Fughhi, Ibtihaj; Campagnoli, Tania; Ali, Amjad; Doukky, Rami

    2017-10-01

    We investigated whether integrating heart rate response (HRR) to regadenoson with myocardial perfusion imaging (MPI) analysis can enhance risk prediction in end-stage renal disease (ESRD) patients. We prospectively followed 303 ESRD patients after regadenoson stress MPI for a mean of 35 months. Normal HRR to regadenoson was defined as ≥28% increase from baseline. Normal MPI was defined as a summed stress score ≤3 and left ventricular ejection fraction ≥50%. The study cohort was divided in four groups based on various combinations of normal/abnormal HRR and MPI. There was a step-wise increase in the risk of primary endpoint of all-cause death and the composite secondary endpoint of cardiac death or myocardial infarction; patients with Normal MPI/Normal HRR had the lowest event rates and those with Abnormal MPI/Abnormal HRR had the highest, whereas subjects with Abnormal MPI/Normal HRR and Normal MPI/Abnormal HRR had intermediate event rates. This pattern was maintained after adjusting for important clinical covariates. In ESRD patients, integrating HRR to vasodilator stress with MPI interpretation improves risk stratification. Normal HRR/Normal MPI identify truly low-risk group, whereas abnormal MPI or abnormal HRR portrays elevated risk.

  6. Accuracy of technetium-99m tetrofosmin myocardial perfusion imaging in the detection of spontaneous recanalization in patients with acute anterior myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Hamada, Shinichi; Nakamura, Seishi; Nishiue, Takashi; Watanabe, Junko; Hatada, Kengo; Miyoshi, Hironori; Iwasaka, Toshiji [Cardiovascular Center, Kansai Medical University, Osaka (Japan); Sugiura, Tetsuro [Dept. of Clinical Laboratory Medicine, Kochi Medical School, Kochi (Japan); Baden, Masato [Division of Cardiology, Takarazuka Hospital, Hyogo (Japan)

    2001-03-01

    To avoid the haemorrhagic risk of unnecessary thrombolysis in acute myocardial infarction (MI), early and precise diagnosis of spontaneous recanalization (SR) of the infarct-related artery is required. To clarify the accuracy of technetium-99m tetrofosmin myocardial single-photon emission tomography (SPET) in the detection of SR in patients with acute anterior MI, electrocardiography (ECG), echocardiography and {sup 99m}Tc-tetrofosmin SPET imaging were performed in 49 patients with acute anterior MI before emergency coronary angiography. Defect score was calculated as the sum of the perfusion defects of each segment: from 3 (complete defect) to 0 (normal perfusion). Echocardiographic asynergic score (the sum of asynergic grades) and the greatest ST elevation of the 12-lead ECG on admission were also measured. SR was defined as Thrombolysis in Myocardial Infarction (TIMI) grade 3 flow on emergency coronary angiography. Defect score in 11 patients with SR (9.2{+-}3.7) was significantly lower than that in 38 patients without SR (18.5{+-}5.0) (P<0.001), whereas there were no significant differences in asynergic score and ST elevation between the two groups. From the receiver operating characteristic curves, the optimal cut-off points of defect score, asynergic score and ST elevation for the detection of SR were calculated to be 12, 13 and 3.5, respectively. The sensitivity and specificity of the scintigraphic defect score (91% and 89%) were significantly higher than those of the asynergic score (64% and 68%) and ST elevation (73% and 71%). Thus, {sup 99m}Tc-tetrofosmin SPET imaging on admission is a very accurate method for the detection of SR in patients with acute anterior MI. (orig.)

  7. Inter-observer agreement and diagnostic accuracy of myocardial perfusion reserve quantification by cardiovascular magnetic resonance at 3 Tesla in comparison to quantitative coronary angiography.

    Science.gov (United States)

    Ikuye, Katharina; Buckert, Dominik; Schaaf, Lisa; Walcher, Thomas; Rottbauer, Wolfgang; Bernhardt, Peter

    2013-03-27

    Quantification of cardiovascular magnetic resonance (CMR) myocardial perfusion reserve (MPR) at 1.5 Tesla has been shown to correlate to invasive evaluation of coronary artery disease (CAD) and to yield good inter-observer agreement. However, little is known about quantitative adenosine-perfusion CMR at 3 Tesla and no data about inter-observer agreement is available. Aim of our study was to evaluate inter-observer agreement and to assess the diagnostic accuracy in comparison to quantitative coronary angiography (QCA). Fifty-three patients referred for coronary x-ray angiography were previously examined in a 3 Tesla whole-body scanner. Adenosine and rest perfusion CMR were acquired for the quantification of MPR in all segments. Two blinded and independent readers analyzed all images. QCA was performed in case of coronary stenosis. QCA data was used to assess diagnostic accuracy of the MPR measurements. Inter-observer agreement was high for all myocardial perfusion territories (ρ = 0.92 for LAD, ρ = 0.93 for CX and RCA perfused segments). Compared to QCA receiver-operating characteristics yielded an area under the curve of 0.78 and 0.73 for RCA, 0.66 and 0.69 for LAD, and 0.52 and 0.53 for LCX perfused territories. Inter-observer agreement of MPR quantification at 3 Tesla CMR is very high for all myocardial segments. Diagnostic accuracy in comparison to QCA yields good values for the RCA and LAD perfused territories, but moderate values for the posterior LCX perfused myocardial segments.

  8. Cell therapy in reperfused acute myocardial infarction does not improve the recovery of perfusion in the infarcted myocardium: a cardiac MR imaging study.

    Science.gov (United States)

    Robbers, Lourens F H J; Nijveldt, Robin; Beek, Aernout M; Hirsch, Alexander; van der Laan, Anja M; Delewi, Ronak; van der Vleuten, Pieter A; Tio, René A; Tijssen, Jan G P; Hofman, Mark B M; Piek, Jan J; Zijlstra, Felix; van Rossum, Albert C

    2014-07-01

    To investigate the effects of cell therapy on myocardial perfusion recovery after treatment of acute myocardial infarction (MI) with primary percutaneous coronary intervention (PCI). In this HEBE trial substudy, which was approved by the institutional review board (trial registry number ISRCTN95796863), the authors assessed the effects of intracoronary infusion with bone marrow-derived mononuclear cells (BMMCs) or peripheral blood-derived mononuclear cells (PBMCs) on myocardial perfusion recovery by using cardiac magnetic resonance (MR) imaging after revascularization. In 152 patients with acute MI treated with PCI, cardiac MR imaging was performed after obtaining informed consent-before randomization to BMMC, PBMC, or standard therapy (control group)-and repeated at 4-month follow-up. Cardiac MR imaging consisted of cine, rest first-pass perfusion, and late gadolinium enhancement imaging. Perfusion was evaluated semiquantitatively with signal intensity-time curves by calculating the relative upslope (percentage signal intensity change). The relative upslope was calculated for the MI core, adjacent border zone, and remote myocardium. Perfusion differences among treatment groups or between baseline and follow-up were assessed with the Wilcoxon signed rank or Mann-Whitney U test. At baseline, myocardial perfusion differed between the MI core (median, 6.0%; interquartile range [IQR], 4.1%-8.0%), border zone (median, 8.4%; IQR, 6.4%-10.2%), and remote myocardium (median, 12.2%; IQR, 10.5%-15.9%) (P < .001 for all), with equal distribution among treatment groups. These interregional differences persisted at follow-up (P < .001 for all). No difference in perfusion recovery was found between the three treatment groups for any region. After revascularization of ST-elevation MI, cell therapy does not augment the recovery of resting perfusion in either the MI core or border zone. © RSNA, 2014.

  9. A Simulation Study of the Effect of Phase-Shift on Dual Gated Myocardial Perfusion ECT.

    Science.gov (United States)

    Lee, Taek-Soo; Park, Min Jae; Tsui, Benjamin M W

    2011-10-01

    We evaluated the effect of relative phase-shift of cardiac and respiratory (C&R) motions in myocardial perfusion (MP) ECT. Previously, we generated a set of realistic 3D XCAT (eXtended CArdiac Torso) phantoms that model simultaneous C&R motions for use in the study of new data acquisition methods and corrective image reconstruction techniques for improved gated MP ECT, including PET and SPECT. The respiratory motion (RM) over a respiration cycle was modeled using 24 equally-spaced time frames while the cardiac beating motion (CBM) over a cardiac cycle was divided into 48 equally-spaced time frames for each of the 24 RM phases. Almost noise-free projection datasets were generated separately from the heart, blood pool, lungs, liver, kidneys, stomach, gall bladder and remaining body at each of the 24 × 48 time points using Monte Carlo simulation techniques that include the effect of collimator detector response, photon attenuation and scatter. To demonstrate the effect of relative phase-shift, a typical (99m)Tc Sestamibi MP SPECT projection dataset were generated. They were then scaled and combined to model different degrees of relative C&R phase shifting and grouped into 6 respiratory-gates with 8 cardiac-gates. Each projection was reconstructed using a 3D OS-EM without and with attenuation correction using an averaged and phase-mismatched gated attenuation maps. The image artifacts of the reconstructed images were compared by visual inspection of the MP polar maps. The results showed significant changes of artifactual non-uniformity in the polar maps for off-phase of RM compared to those of CBM. The changes in the polar maps also demonstrated the effect of phase shifting accordingly. We conclude that the 4D XCAT phantom dataset with simultaneous C&R motions provides a powerful tool in the study of the effects of C&R motions with relative phase shifts, and development of C&R gating schemes and motion correction methods for improved ECT/CT imaging.

  10. Minimizing patient-specific tracer dose in myocardial perfusion imaging using CZT SPECT.

    Science.gov (United States)

    van Dijk, Joris D; Jager, Pieter L; Ottervanger, Jan Paul; Slump, Cornelis H; de Boer, Jaep; Oostdijk, Adrianus H J; van Dalen, Jorn A

    2015-03-01

    Myocardial perfusion imaging (MPI) with SPECT is widely adopted in clinical practice but is associated with a relatively high radiation dose. The aim of this study was to determine the minimum product of tracer dose and scan time that will maintain diagnostic value for cadmium zinc telluride (CZT) SPECT MPI. Twenty-four patients underwent clinically indicated stress MPI using CZT SPECT and a body weight-dependent (3 MBq/kg) (99m)Tc-tetrofosmin tracer dose. Data were acquired for 8 min in list mode. Next, images were reconstructed using 2-, 4-, 6-, and 8-min time frames. Differences between the 8-min reference scan and the shorter scans were determined in segmental uptake values (using the 17-segment cardiac model), ejection fraction, and end-diastolic volume. A 5% difference in segmental uptake was considered to significantly influence the diagnostic value. Next, the quality of the 4-, 6-, and 8-min scans was scored on a 4-point scale by consensus by 3 experienced nuclear medicine physicians. The physicians did not know the scan time or patient information. Differences in segmental uptake values, ejection fraction, and end-diastolic volume were greater for shorter scans than for the 8-min reference scan. On average, the diagnostic value was influenced in 7.7 segments per patient using the 2-min scans, in comparison to 2.0 and 0.8 segments per patient using the 4- and 6-min scans, respectively. In addition, the 4-min scans led to a significantly reduced image quality compared with the 8-min scans (P < 0.05). This was not the case for the 6-min scan. Six minutes was the shortest acquisition time in stress MPI using CZT SPECT that did not affect the diagnostic value for a tracer dose of 3 MBq/kg. Hence, the patient-specific product of tracer dose and scan time can be reduced to a minimum of 18 MBq·min/kg, which may lower the effective radiation dose for patients to values below 1 mSv. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  11. Myocardial scintigraphy in the diagnosis of myocardial contusion

    Energy Technology Data Exchange (ETDEWEB)

    Terashima, Masayoshi; Shinoda, Mitsutaka; Iwama, Hiroshi; Hirama, Hisao; Hoshino, Toshiaki; Urabe, Shinpei [Central Aizu General Hospital, Fukushima (Japan); Meguro, Taiichiroh

    1996-04-01

    To assess the clinical value of a new fatty acid imaging tracer, {sup 123}I-{beta}-methyl iodophenyl pentadecanoic acid (BMIPP), I-BMIPP and thallium-201 (Tl) dual imaging was performed at rest in fifteen patients with mild blunt chest trauma (mean AIS thoracic 1.4{+-}0.51, mean ISS 6.47{+-}3.50, mean RTS 7.69{+-}0.43). All patients were prospectively evaluated on the basis of serial electrocardiograms (ECG) and cardiac enzyme studies (total CPK). Tl and BMIPP dual scintigrams were performed within 10 days following admission. SPECT images were divided into seven segments, and the segmental images were visually scored according to tracer uptake on a 3 (severely decreased tracer uptake) to 0 (normal) scale. Nine patients had scintigraphic defects and were considered to have a myocardial contusion. ECG findings, AIS, ISS, and CPK levels failed to distinguish between scintigraphically positive patients and scintigraphically negative patients. Five of the 14 hypoperfused segments on BMIPP imaging, showed normal Tl uptake, one showed lower BMIPP uptake than Tl, and the remaining eight showed similar distribution of both tracers. The mismatch between tracer uptake on BMIPP images and Tl images was thought to reflect impaired myocardial fatty acid metabolism. Thus, mild blunt chest trauma results in a higher frequency of traumatic myocardial injury than previously recognized, and BMIPP is a promising radio-pharmaceutical for evaluating impaired myocardial fatty acid metabolism in patients with myocardial contusion. (author).

  12. Comparison of the Peripheral Reactive Hyperemia Index with Myocardial Perfusion Reserve by (82)Rb PET/CT in HIV-Infected Patients

    DEFF Research Database (Denmark)

    Ørbæk, Mathilde; Hasbak, Philip; Sejersten Ripa, Rasmus

    2017-01-01

    After the introduction of antiretroviral therapy (ART) the life expectancy of patients infected with human immunodeficiency virus (HIV) is now approaching that of the general population and the importance of non-AIDS co-morbidities is increasing. Specifically, the risk of coronary artery disease...... previously undergone measurement of the myocardial perfusion reserve by (82)-rubidium PET/CT for study purposes. We found an inverse correlation between the reactive hyperemia index and the myocardial perfusion reserve which most likely indicates different vascular physiology. This study did not find...

  13. Area at risk can be assessed by iodine-123-meta-iodobenzylguanidine single-photon emission computed tomography after myocardial infarction: a prospective study.

    Science.gov (United States)

    Hedon, Christophe; Huet, Fabien; Ben Bouallegue, Fayçal; Vernhet, Hélène; Macia, Jean-Christophe; Cung, Thien-Tri; Leclercq, Florence; Cade, Stéphane; Cransac, Frédéric; Lattuca, Benoit; Vandenberghe, D'Arcy; Bourdon, Aurélie; Benkiran, Meriem; Vauchot, Fabien; Gervasoni, Richard; D'estanque, Emmanuel; Mariano-Goulart, Denis; Roubille, François

    2018-02-01

    Myocardial salvage is an important surrogate endpoint to estimate the impact of treatments in patients with ST-segment elevation myocardial infarction (STEMI). The aim of this study was to evaluate the correlation between cardiac sympathetic denervation area assessed by single-photon emission computed tomography (SPECT) using iodine-123-meta-iodobenzylguanidine (I-MIBG) and myocardial area at risk (AAR) assessed by cardiac magnetic resonance (CMR) (gold standard). A total of 35 postprimary reperfusion STEMI patients were enrolled prospectively to undergo SPECT using I-MIBG (evaluates cardiac sympathetic denervation) and thallium-201 (evaluates myocardial necrosis), and to undergo CMR imaging using T2-weighted spin-echo turbo inversion recovery for AAR and postgadolinium T1-weighted phase sensitive inversion recovery for scar assessment. I-MIBG imaging showed a wider denervated area (51.1±16.0% of left ventricular area) in comparison with the necrosis area on thallium-201 imaging (16.1±14.4% of left ventricular area, Parea (P=0.23) and was adequately correlated (R=0.56, P=0.0002). Myocardial salvage evaluated by SPECT imaging (mismatch denervated but viable myocardium) was significantly higher than by CMR (P=0.02). In patients with STEMI, I-MIBG SPECT, assessing cardiac sympathetic denervation may precisely evaluate the AAR, providing an alternative to CMR for AAR assessment.

  14. Prognostic value of normal exercise {sup 99m}Tc-MIBI myocardial perfusion SPECT: comparison with exercise electrocardiography and coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang Woo; Lee, Jae Tae; Chun, Kyung Ah; Kang, Do Young; Kim, Dong Hwan; Cho, Yong Keun; Chae, Shung Chull; Lee, Kyu Bo [Kyungpook National Univ. College of Medicine, Taegu (Korea, Republic of)

    2000-06-01

    Myocardial perfusion scintigraphy is a useful technique to diagnose and to predict prognosis in patients with suspected or known coronary artery disease. The purpose of the present study is to evaluate the prognostic value of normal exercise {sup 99m}Tc-MIBI myocardial perfusion single photon emission computed tomography (SPECT) and to analyze results with regard to those of exercise electrocardiography or coronary angiography. We evaluated 301 patients (mean age 52{+-}10 years, 166 males and 135 females) with normal exercise {sup 99m}Tc-MIBI myocardial perfusion SPECT performed for suspected coronary artery disease. Subjects were evaluated for cardiac events and followed for 8-55 months (mean 19{+-}10 months) after imaging. During the follow-up period, there was no cardiac death but only one non-fatal myocardial infarction (event rate 0.21% per year). In addition, only one patient underwent coronary revascularization. There was no significant difference in cardiac event rate between patinets with positive (n=3D27) and negative (n=3D235) exercise electrocardiography (p:NS). There was no cardiac event in 17 patients who underwent coronary angiography (4 patients with >50% luminal narrowing, 2 patients with vasospasm and 11 patients with no significant lesion). Patients with normal exercise {sup 99m}Tc-MIBI myocardial perfusion SPECT has a very low risk for cardiac events regardless of exercise electrocardiographic and coronary angiographic findings.

  15. Adenosine versus regadenoson comparative evaluation in myocardial perfusion imaging: results of the ADVANCE phase 3 multicenter international trial.

    Science.gov (United States)

    Iskandrian, Ami E; Bateman, Timothy M; Belardinelli, Luiz; Blackburn, Brent; Cerqueira, Manuel D; Hendel, Robert C; Lieu, Hsiao; Mahmarian, John J; Olmsted, Ann; Underwood, S Richard; Vitola, João; Wang, Whedy

    2007-01-01

    Earlier phase 1 and 2 studies have shown that regadenoson has desirable features as a stress agent for myocardial perfusion imaging. This multicenter, double-blinded phase 3 trial involved 784 patients at 54 sites. Each patient underwent 2 sets of gated single photon emission computed tomography myocardial perfusion imaging studies: an initial qualifying study with adenosine and a subsequent randomized study with either regadenoson (2/3 of patients) or adenosine. Regadenoson was administered as a rapid bolus (adenosine-regadenoson images and adenosine-adenosine images, lay above a prespecified noninferiority margin. Other prospectively defined safety and tolerability comparisons and supporting analyses were also performed. The average agreement rate based on the median of 3 independent blinded readers was 0.63 +/- 0.03 for regadenoson-adenosine and 0.64 +/- 0.04 for adenosine-adenosine-a 1% absolute difference with the lower limit of the 95% confidence interval lying above the prespecified noninferiority margin. Side-by-side interpretation of regadenoson and adenosine images provided comparable results for detecting reversible defects. The peak increase in heart rate was greater with regadenoson than adenosine, but the blood pressure nadir was similar. A summed symptom score of flushing, chest pain, and dyspnea was less with regadenoson than adenosine (P = .013). This phase 3 trial shows that regadenoson provides diagnostic information comparable to a standard adenosine infusion. There were no serious drug-related side effects, and regadenoson was better tolerated than adenosine.

  16. Using a registration-based motion correction algorithm to correct for respiratory motion during myocardial perfusion imaging.

    Science.gov (United States)

    Redgate, Shelley; Barber, David C; Al-Mohammad, Abdallah; Tindale, Wendy B

    2013-08-01

    The aim of the study was to develop and evaluate a registration-based motion correction algorithm as a method of reducing respiratory motion artefacts in myocardial perfusion imaging. The NCAT software was used to build nine male and nine female computer simulations of myocardial perfusion imaging data, with different respiratory motions and left ventricular ejection fractions. Imaging data were generated at various time points throughout each cardiac cycle. The data were summed over each cardiac cycle, forward projected, normalized, noise added and reconstructed with and without motion correction. Motion correction was performed using an algorithm that aligns images within a projection using nonlinear registrations. A standard simulation with no respiratory motion was also generated for comparison. The algorithm was applied to the standard to determine its effect on images with no respiratory motion. The median difference in mean segmental counts compared with the standard was calculated for each simulation. The mean (range) of these values was 3% (1-6%), 14% (12-16%) and 28% (28-29%) for displacements of 1, 2 and 3 cm, respectively. The largest changes occurred inferiorly and anteriorly. Motion correction reduced these differences to 2% (0-4%), 5% (2-7%) and 7% (7-7%), respectively. The process of correcting for motion reduced the mean counts in all segments by 3% (1-5%). Artefacts resulting from respiratory motion are improved using our algorithm when motion is 2 cm or greater.

  17. Evaluation of Patients with Acute Chest Pain Using SPECT Myocardial Perfusion Imaging: Prognostic Implications of Mildly Abnormal Scans.

    Science.gov (United States)

    Goldkorn, Ronen; Naimushin, Alexey; Beigel, Roy; Naimushin, Ekaterina; Narodetski, Michael; Matetzky, Shlomi

    2017-06-01

    While patients presenting to emergency departments (ER) with chest pain are increasingly managed in chest pain units (CPU) that utilize accelerated diagnostic protocols for risk stratification, such as single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI), data are lacking regarding the prognostic implications of mildly abnormal scans in this population. To evaluate the prognostic implications of mildly abnormal SPECT MPI results in patients with acute chest pain. Of the 3753 chest pain patients admitted to the CPU at the Leviev Heart Center, Sheba Medical Center 1593 were further evaluated by SPECT MPI. Scans were scored by extent and severity of stress-induced perfusion defects, with 1221 patients classified as normal, 82 with myocardial infarction without ischemia, 236 with mild ischemia, and 54 with more than mild ischemia. Mild ischemia patients were further classified to those who did and did not undergo coronary angiography within 7 days. Mild ischemia patients who underwent coronary angiography were more likely to be male (92% vs. 81%, P = 0.01) and to have left anterior descending ischemia (67% vs. 42%, P = 0.004). After 50 months, these patients returned less often to the ER with chest pain (53% vs. 87%, P acute coronary syndrome and death (8% vs. 16%, P patients with chronic stable angina, patients presenting with acute chest pain exhibiting mildly abnormal SPECT MPI findings should perhaps undergo a more aggressive diagnostic and therapeutic approach.

  18. Optimization of OSEM parameters in myocardial perfusion imaging reconstruction as a function of body mass index: a clinical approach*

    Science.gov (United States)

    de Barros, Pietro Paolo; Metello, Luis F.; Camozzato, Tatiane Sabriela Cagol; Vieira, Domingos Manuel da Silva

    2015-01-01

    Objective The present study is aimed at contributing to identify the most appropriate OSEM parameters to generate myocardial perfusion imaging reconstructions with the best diagnostic quality, correlating them with patients’ body mass index. Materials and Methods The present study included 28 adult patients submitted to myocardial perfusion imaging in a public hospital. The OSEM method was utilized in the images reconstruction with six different combinations of iterations and subsets numbers. The images were analyzed by nuclear cardiology specialists taking their diagnostic value into consideration and indicating the most appropriate images in terms of diagnostic quality. Results An overall scoring analysis demonstrated that the combination of four iterations and four subsets has generated the most appropriate images in terms of diagnostic quality for all the classes of body mass index; however, the role played by the combination of six iterations and four subsets is highlighted in relation to the higher body mass index classes. Conclusion The use of optimized parameters seems to play a relevant role in the generation of images with better diagnostic quality, ensuring the diagnosis and consequential appropriate and effective treatment for the patient. PMID:26543282

  19. Stress and rest dynamic myocardial perfusion imaging by evaluation of complete time-attenuation curves with dual-source CT.

    Science.gov (United States)

    Ho, Kheng-Thye; Chua, Kia-Chong; Klotz, Ernst; Panknin, Christoph

    2010-08-01

    This study sought to describe a protocol for myocardial perfusion imaging using dipyridamole stress, with 128-slice dual-source computed tomography (CT), and to assess the ability of CT myocardial perfusion imaging (MPI) to detect abnormal flow reserve and infarction in comparison with nuclear MPI (NMPI). CT MPI has not been previously described with the 128-slice dual-source CT scanner, or with the complete evaluation of dynamic time-attenuation curves of the myocardium. Thirty-five patients underwent a stress CT MPI protocol. Complete time-attenuation curves of the myocardium were acquired using a novel scan mode, which acquires prospectively electrocardiogram (ECG)-triggered axial images at 2 rapidly alternating positions. Myocardial blood flow (MBF) values of fixed and reversible defects obtained were compared between rest and stress. Findings on CT MPI were correlated to NMPI. Perfusion defects detected on CT were correlated to coronary stenoses detected on CT angiography (CTA) and invasive coronary angiography (ICA). There was a 1.5-fold difference between stress (1.21 +/- 0.31 cc/cc/min) and rest (0.82 +/- 0.22 cc/cc/min) MBF in normal tissue. In reversible defects, MBF was 0.65 +/- 0.21 cc/cc/min and 0.63 +/- 0.18 cc/cc/min at stress and rest, respectively. In fixed defects, the MBF was 0.57 +/- 0.22 cc/cc/min at stress and 0.54 +/- 0.23 cc/cc/min at rest. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of CT MPI for identifying segments with perfusion defects was 0.83, 0.78, 0.79, and 0.82, respectively. ICA results were available for 30 patients. Sensitivity, specificity, PPV, and NPV of CT MPI compared with ICA were 0.95, 0.65, 0.78, and 0.79, respectively. The radiation dose for CT MPI was 9.15 +/- 1.32 mSv for the stress scan and 9.09 +/- 1.40 mSv for the rest scan. Vasodilator-stress CT MPI may be feasible in human subjects at a radiation dose similar to NMPI. It identifies areas of abnormal flow reserve

  20. Assessment of global myocardial perfusion reserve using cardiovascular magnetic resonance of coronary sinus flow at 3 Tesla

    Science.gov (United States)

    2014-01-01

    Background Despite increasing clinical use, there is limited data regarding regadenoson in stress perfusion cardiovascular magnetic resonance (CMR). In particular, given its long half-life the optimal stress protocol remains unclear. Although Myocardial Perfusion Reserve (MPR) may provide additive prognostic information, current techniques for its measurement are cumbersome and challenging for routine clinical practice. The aims of this study were: 1) To determine the feasibility of MPR quantification during regadenoson stress CMR by measurement of Coronary Sinus (CS) flow; and 2) to investigate the role of aminophylline reversal during regadenoson stress-CMR. Methods 117 consecutive patients with possible myocardial ischemia were prospectively enrolled. Perfusion imaging was performed at 1 minute and 15 minutes after administration of 0.4 mg regadenoson. A subgroup of 41 patients was given aminophylline (100 mg) after stress images were acquired. CS flow was measured using phase-contrast imaging at baseline (pre CS flow), and immediately after the stress (peak CS flow) and rest (post CS flow) perfusion images. Results CS flow measurements were obtained in 92% of patients with no adverse events. MPR was significantly underestimated when calculated as peak CS flow/post CS flow as compared to peak CS flow/pre CS flow (2.43 ± 0.20 vs. 3.28 ± 0.32, p = 0.03). This difference was abolished when aminophylline was administered (3.35 ± 0.44 vs. 3.30 ± 0.52, p = 0.95). Impaired MPR (peak CS flow/pre CS flow Regadenoson stress CMR with MPR measurement from CS flow can be successfully performed in most patients. This measurement of MPR appears practical to perform in the clinical setting. Residual hyperemia is still present even 15 minutes after regadenoson administration, at the time of resting-perfusion acquisition, and is completely reversed by aminophylline. Our findings suggest routine aminophylline administration may be required when

  1. Non invasive evaluation of the coronary atherosclerosis illness in patients with silent ischemia: utility of the SPECT of myocardial perfusion. Electric, angiographic and image correlation; Valoracion no invasiva de la enfermedad ateroesclerosa coronaria en pacientes con isquemia silente: utilidad del SPECT de perfusion miocardica. Correlacion electrica, angiografica y de imagen

    Energy Technology Data Exchange (ETDEWEB)

    Puente B, A.; Roffe G, F.; Aceves C, J.; Gomez A, E. [Hospital Centro Medico Nacional 20 de Noviembre, ISSSTE, Mexico D.F. (Mexico)

    2005-07-01

    The objective of the work was to determine the utility of the SPECT (Single Photon Emission Computerized Tomography) of myocardial perfusion for the ischemia detection in asymptomatic patients with Coronary Atherosclerosis Illness. It was concluded that the SPECT of myocardial perfusion has a high sensitivity (97%) for the silent ischemia diagnosis.

  2. Normal value of functional parameters in gated myocardial perfusion SPECT in patients with low risk of coronary artery disease: emory cardiac tool box program

    Energy Technology Data Exchange (ETDEWEB)

    Kang, D. Y.; Kim, M. H.; Kim, Y. D.; Kim, D. K. [Donga University College of Medicine, Busan (Korea, Republic of)

    2002-07-01

    Absolute value of the functional data of gated myocardial perfusion SPECT is necessary to determine that individual patient is normal or not. Tc-99m MIBI gated myocardial perfusion SPECT was performed using emory cardiac tool box program. All patients (M:F=15:36, age 64{+-}10 yrs) showed normal myocardial perfusion. The patients with following characteristics were excluded; previous angina or MI, ECG change with Q wave or ST-T change, diabetes mellitus, hypercholesterolemia, typical chest pain and hypertension. In all patients, myocardial mass is 117{+-}23 g in stress gated SPECT, 106{+-}22 g in stress ungated SPECT and 102{+-}21 g in rest ungated SPECT. EDV is 90{+-}28 ml, ESV 26{+-}20 ml, SV 66{+-}21 ml, EF 73{+-}10 % and TID 1.06{+-}0.14. Myocardial mass in rest ungated SPECT is significantly different between men and women (p=0.025). Myocardial mass is significantly different between stress gated SPECT and stress ungated SPECT (p=0.000), and between stress ungated SPECT and rest ungated SPECT (p=0.003). We provide normal value of functional parameters to determine the abnormality of individual patients in patients with low risk of coronary artery disease.

  3. Left ventricular dilatation and pulmonary thallium uptake after single-photon emission computer tomography using thallium-201 during adenosine-induced coronary hyperemia

    Energy Technology Data Exchange (ETDEWEB)

    Iskandrian, A.S.; Heo, J.; Nguyen, T.; Lyons, E.; Paugh, E. (Philadelphia Heart Institute, PA (USA))

    1990-10-01

    This study examined the implications of left ventricular (LV) dilatation and increased pulmonary thallium uptake during adenosine-induced coronary hyperemia. The lung-to-heart thallium ratio in the initial images was significantly higher in patients with coronary artery disease (CAD) than normal subjects; 0.48 +/- 0.16 in 3-vessel disease (n = 16), 0.43 +/- 0.10 in 2-vessel disease (n = 20), 0.43 +/- 0.08 in 1-vessel disease (n = 16) and 0.36 +/- 0.05 in normal subjects (n = 7) (p less than 0.001, 0.09 and 0.06, respectively). There was a significant correlation between the severity and the extent of the perfusion abnormality (determined from the polar maps) and the lung-to-heart thallium ratio (r = 0.51 and 0.52, respectively, p less than 0.0002). There was also a significant correlation between lung thallium washout and lung-to-heart thallium ratio (r = 0.42, p = 0.0009) and peak heart rate (r = -0.49, p less than 0.0001). The LV dilatation was mostly due to an increase in cavity dimension (30% increase) and to a lesser extent (6% increase) due to increase in LV size. (The cavity dimensions were measured from the short-axis slices at the midventricular level in the initial and delayed images). The dilation was seen in patients with CAD but not in the normal subjects. These changes correlated with the extent and severity of the thallium perfusion abnormality. Thus, adenosine-induced coronary hyperemia may cause LV dilation and increased lung thallium uptake on the basis of subendocardial ischemia.

  4. A new method of detecting subendocardial ischemia in patients with aortic valvular stenosis without coronary artery disease using thallium-201 single photon emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Umamoto, Ikuo; Sugihara, Hiroki; Harada, Yoshiaki (Kyoto Prefectural Univ. of Medicine (Japan)) (and others)

    1993-02-01

    The purpose of this study was to detect myocardial ischemia in aortic valvular stenosis (AVS) without coronary artery disease by using exercise Tl-201 SPECT. The subjects were 18 AVS patients. Twenty other patients were served as controls. Transient 'left ventricular subendocardial dilation and decreased wall thickness', obtained on early SPECT images, were quantitatively determined by transient dilation index (TDI). Washout rates (WR) were calculated from overlapping early and delayed images to obtain WR map. According to TDI, 18 AVS patients were classified as having TDI[<=]1.11 (Group A, n=9) and TDI>1.11 (Group B, n=9). WR map in Group B presented the direction from the pericardial toward the endocardial side, revealing a pattern of decreased WR and a decreased coronary flow reserve on the endocardial side. Both pressure gradient between the aorta and left ventricle and left ventricular wall thickness were significantly greater in Group B than Group A. In 3 patients in Group B, TDI returned to normal and WR map became homogeneous after aortic valve replacement. In addition, fibrosis was noted in the endocardial site on biopsy. In AVS associated with great pressure gradient, endocardial ischemia may occur on exercise, resulting from a decreased coronary flow reserve, and a decreased compliance due to fibrosis and hypertrophy. Exercise Tl-201 myocardial SPECT is capable of detecting distribution patterns of subendocardial ischemia and coronary flow reserve in AVS. (N.K.).

  5. Prognostic value of normal stress-only myocardial perfusion imaging: a comparison between conventional and CZT-based SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Yokota, Shu; Ottervanger, Jan Paul; Timmer, Jorik R. [Isala Hospital, Department of Cardiology, Zwolle (Netherlands); Mouden, Mohamed; Engbers, Elsemiek [Isala Hospital, Department of Cardiology, Zwolle (Netherlands); Isala Hospital, Department of Nuclear Medicine, Zwolle (Netherlands); Knollema, Siert; Jager, Pieter L. [Isala Hospital, Department of Nuclear Medicine, Zwolle (Netherlands)

    2016-02-15

    Single photon emission computed tomography (SPECT) myocardial perfusion imaging has proven to have prognostic importance in patients with suspected stable coronary artery disease (CAD). The recently introduced ultrafast cadmium zinc telluride (CZT)-based gamma cameras have been associated with less equivocal findings and more normal interpretations, allowing stress-only imaging to be performed more often. However, it is yet unclear whether normal stress-only CZT SPECT has comparable prognostic value as normally interpreted stress-only conventional SPECT. The study population consisted of 1,650 consecutive patients without known CAD with normal stress-only myocardial perfusion results with either conventional (n = 362) or CZT SPECT (n = 1,288). The incidence of major adverse cardiac events (MACE, all-cause death, non-fatal myocardial infarction and/or coronary revascularization) was compared between the conventional SPECT and CZT SPECT groups. Multivariable analyses using the Cox model were used to adjust for differences in baseline variables. Patients scanned with CZT were less often male (33 vs 39 %), had less often hypercholesterolaemia (41 vs 50 %) and had more often a family history of CAD (57 vs 49 %). At a median follow-up time of 37 months (interquartile range 28-45 months) MACE occurred in 68 patients. The incidence of MACE was 1.5 %/year in the CZT group, compared to 2.0 %/year in the conventional group (p = 0.08). After multivariate analyses, there was a trend to a lower incidence of MACE in the CZT SPECT group (hazard ratio 0.61, 95 % confidence interval 0.35-1.04, p = 0.07). The prognostic value of normal stress-only CZT SPECT is at least comparable and may be even better than that of normal conventional stress SPECT. (orig.)

  6. Detection of myocardial perfusion abnormalities: standard dual-source coronary computed tomography angiography versus rest/stress technetium-99m single-photo emission CT.

    Science.gov (United States)

    Cheng, W; Zeng, M; Arellano, C; Mafori, W; Goldin, J; Krishnam, M; Ruehm, S G

    2010-08-01

    We compared coronary dual-source computed tomography angiography (corDSCTA) with technetium-99m single-photon emission computed tomography (SPECT) for the detection of myocardial perfusion abnormalities. Fifty-five consecutive patients underwent both gated myocardial perfusion SPECT and corDSCTA, the latter during a single arterial-phase injection of contrast agent. The perfusion defects visualised by corDSCTA correlated with the findings of rest/stress SPECT. Abnormal findings on stress SPECT, which were due to either ischaemia or infarct, were found in 24 patients. In comparison to SPECT at rest, corDSCTA detected perfusion defects with a sensitivity and specificity of 100% and 78%, respectively. Compared to SPECT at stress, the sensitivity and specificity values of corDSCTA were 83.3% and 90.3%, respectively. On corDSCTA , the average attenuation values of perfusion defects that corresponded to chronic infarcts (-8.5+/-22.2 HU) were significantly lower (p = 0.002) than those of non-infarct-related perfusion defects (43.1+/-17.5 HU). Using rest/stress SPECT is the gold standard for the diagnosis of myocardial ischaemia, corDSCTA was able to diagnose ischaemic disease (defined as the presence of high-grade stenotic CAD (>or=50% luminal narrowing)) with a sensitivity and specificity of 59% and 89%, respectively, in patients with no known history of myocardial infarction (n = 4). Thus, corDSCTA may serve as a diagnostic tool for the detection of perfusion abnormalities (first) visualised by SPECT. There appears to be a limited correlation between coronary stenotic disease and SPECT findings.

  7. The dream of a one-stop-shop : Meta-analysis on myocardial perfusion CT

    NARCIS (Netherlands)

    Pelgrim, Gert Jan; Dorrius, Monique; Xie, Xueqian; den Dekker, Martijn A. M.; Schoepf, U. Joseph; Henzler, Thomas; Oudkerk, Matthijs; Vliegenthart, Rozemarijn

    2015-01-01

    Purpose: To determine the diagnostic performance of computed tomography (CT) perfusion techniques for the detection of functionally relevant coronary artery disease (CAD) in comparison to reference standards, including invasive coronary angiography (ICA), single photon emission computed tomography

  8. Mapping contrast agent uptake and retention in MRI studies of myocardial perfusion: case control study of dogs with Duchenne muscular dystrophy.

    Science.gov (United States)

    Kerwin, William S; Naumova, Anna; Storb, Rainer; Tapscott, Stephen J; Wang, Zejing

    2013-04-01

    Myocardial perfusion studies using dynamic contrast-enhanced cardiac magnetic resonance imaging (CMRI) could provide valuable, quantitative information regarding heart physiology in diseases such as Duchenne muscular dystrophy (DMD), that lead to diffuse myocardial damage. The goal of this effort was to develop an intuitive but physiologically meaningful method for quantifying myocardial perfusion by CMRI and to test its ability to detect global myocardial differences in a dog model of DMD. A discrete-time model was developed that parameterizes contrast agent kinetics in terms of an uptake coefficient that describes the forward flux of contrast agent into the tissue, and a retention coefficient that describes the rate of decay in tissue concentration due to contrast agent efflux. This model was tested in 5 dogs with DMD and 6 healthy controls which were imaged using a perfusion sequence on a 3T clinical scanner. CINE and delayed-enhancement CMRI acquisitions were also used to assess cardiac function and the presence of myocardial scar. Among functional parameters measured by CMRI, no significant differences were observed. No myocardial scar was observed. Increased perfusion in DMD was observed with an uptake coefficient of 6.76 ± 2.41 % compared to 2.98 ± 1.46 % in controls (p = 0.03). Additionally, the retention coefficient appeared lower at 82.2 ± 5.8 % in dogs with DMD compared to 90.5 ± 6.6 % in controls (p = 0.12). A discrete-time kinetic model of uptake and retention of contrast agent in perfusion CMRI shows potential for the study of DMD.

  9. Effects of prasugrel pretreatment on angiographic myocardial perfusion parameters in patients with ST-elevation myocardial infarction undergoing primary percutaneous coronary intervention.

    Science.gov (United States)

    Perl, Leor; Sasson, Liat; Weissler-Snir, Adaya; Greenberg, Gabriel; Vaknin-Assa, Hana; Kornowski, Ran; Assali, Abid; Lev, Eli I

    2015-12-01

    Prasugrel is a third-generation thienopyridine, with significant pharmacodynamic and clinical advantages over clopidogrel. There are few data on the effects of prasugrel therapy, as compared with clopidogrel, in terms of perfusion during percutaneous coronary intervention (PCI), in patients with ST-elevation myocardial infarction (STEMI). A total of 128 patients with STEMI, pretreated with prasugrel 60 mg loading dose (mean age=55.9±9.1; 10.9% were women and 18.0% had diabetes), were compared with 128 propensity-matched patients pretreated with clopidogrel 600 mg (mean age=58.7±10.7; 10.2% were women and 19.5% had diabetes) for the primary endpoint of thrombolysis in myocardial infarction (TIMI) flow and myocardial blush grade at completion of the PCI. Secondary endpoints included the combined sum of major adverse events: death, reinfarction or target vessel revascularization at 1 year. Mean TIMI flow grade pre-PCI was similar between the two groups (1.31±1.3 in the prasugrel group and 1.30±1.2 in the clopidogrel group, P=0.96). However, after intervention, it was higher in the prasugrel group (2.94±0.24 vs. 2.84±0.37, respectively, P=0.016), as was myocardial blush (2.70±0.76 vs. 2.31±0.52, respectively, P<0.001). The percentage of TIMI 3 after intervention was also higher in the prasugrel group (97.70 vs. 90.60%, P=0.02). The combined rate of major adverse events at 1 year (8.7 vs. 11.6%, P=0.11), as well as total mortality (3.1±5.6 vs. 4.7±9.1%, P=0.52), did not differ between the two groups. In patients with STEMI undergoing primary PCI, pretreatment with prasugrel resulted in better angiographic perfusion results, as compared with pretreatment with clopidogrel.

  10. The Benefits of Prone SPECT Myocardial Perfusion Imaging in Reducing Both Artifact Defects and Patient Radiation Exposure

    Directory of Open Access Journals (Sweden)

    Maria Stathaki

    2015-10-01

    Full Text Available AbstractBackground:Prone imaging has been demonstrated to minimize diaphragmatic and breast tissue attenuation.Objectives:To determine the role of prone imaging on the reduction of unnecessary rest perfusion studies and coronary angiographies performed, thus decreasing investigation time and radiation exposure.Methods:We examined 139 patients, 120 with an inferior wall and 19 with an anterior wall perfusion defect that might represented attenuation artifact. Post-stress images were acquired in both the supine and prone position. Coronary angiography was used as the “gold standard” for evaluating coronary artery patency. The study was terminated and rest imaging was obviated in the presence of complete improvement of the defect in the prone position. Quantitative interpretation was performed. Results were compared with clinical data and coronary angiographic findings.Results:Prone acquisition correctly revealed defect improvement in 89 patients (89/120 with inferior wall and 12 patients (12/19 with anterior wall attenuation artifact. Quantitative analysis demonstrated statistically significant difference in the mean summed stress scores (SSS of supine and mean SSS of prone studies in patients with disappearing inferior wall defect in the prone position and patent right coronary artery (true negative results. The mean difference between SSS in supine and in prone position was higher with disappearing than with remaining defects.Conclusion:Technetium-99m (Tc-99m tetrofosmin myocardial perfusion imaging with the patient in the prone position overcomes soft tissue attenuation; moreover it provides an inexpensive, accurate approach to limit the number of unnecessary rest perfusion studies and coronary angiographies performed.

  11. A micro-SPECT imaging pilot study of myocardial perfusion in mice; Etude pilote de la perfusion myocardique chez la souris par micro-imagerie TEMP

    Energy Technology Data Exchange (ETDEWEB)

    Constantinesco, A.; Choquet, P.; Israel-Jost, V. [Hopital de Hautepierre, Service de Biophysique et Medecine Nucleaire, 67 - Strasbourg (France); Israel-Jost, V.; Sonnendrucker, E. [Institut de Recherche Mathematique Avancee de Strasbourg, 67 (France); Monassier, L. [Institut National de la Sante et de la Recherche Medicale (INSERM U333), 67 - Strasbourg (France); Elfertak, L. [Institut Clinique de la Souris (ICS), 67 - Illkirch (France)

    2004-04-01

    Objective: demonstrate the feasibility of micro-SPECT for myocardial perfusion imaging in mice. Methods: a micro-SPECT dedicated camera with a field of view of 17 cm x 17 cm, a 1,5 mm pinhole with a focal distance of 12 cm was used. An infra millimetric linear phantom permitted to measure the planar and tomographic FWHM. Two normal adult mice were studied under gaseous anaesthesia (isoflurane 1,5%) and after IV administration of 0,1 mL of {sup 99m}Tc-Sestamibi (350 MBq) in one case and {sup 201}Tl (64 MBq) in the other case. In the two cases, 48 projections of 1 mn over 180 deg C in a 64 x 64 image format with a radius of rotation of 2,5 cm were used with a 20% window centered on the photoelectric peak of 99mTc or the 71 KeV of {sup 201}Tl. Tomographic reconstruction was done with a specific ART cone beam algorithm. Results: phantoms FWHM were respectively 1.6 mm and 1.5 mm in planar and tomographic modes with a reconstructed field of view of 26 mm and 1 mm when the reconstructed field of view was 10 mm. Micro-SPECT perfusion images using a reconstructed voxel volume of 0.064 mm{sup 3} of the mice myocardium were obtained with a better anatomical resolution with Sestamibi than thallium. Conclusion: this pilot study demonstrate the potential of micro-SPECT imaging for mice nuclear cardiology. (author)

  12. Effect of changes in perfusion defect size during serial regadenoson myocardial perfusion imaging on cardiovascular outcomes in high-risk patients.

    Science.gov (United States)

    El-Hajj, Stephanie; AlJaroudi, Wael A; Farag, Ayman; Bleich, Steven; Manaoragada, Padma; Iskandrian, Ami E; Hage, Fadi G

    2016-02-01

    The prognostic value of single-photon emission computed tomography myocardial perfusion imaging (MPI) is well established. There is a paucity of data on the prognostic value of changes in perfusion defect size (PDS) on serial MPIs. From the MPI database at the University of Alabama at Birmingham, consecutive patients who underwent two regadenoson stress MPIs between July 2008 and March 2013 were identified. The MPIs were analyzed side-by-side using an automated software program for presence and change in PDS. Improvement in PDS was defined as a reduction ≥5% of left ventricle. A drop in left ventricular ejection fraction (LVEF) was defined as a decrease ≥5%. The primary outcome was a composite of death, myocardial infarction (MI), and coronary revascularization (CR). There were 698 patients (61 ± 11 years, 53% male, 48% diabetes, 25% prior MI, 49% prior CR) who underwent two regadenoson MPIs within 16 ± 9 months for clinical indications. The primary outcome occurred in 167 (24%) patients (8% death, 9% MI, 15% CR) during 24 ± 16 months of follow-up after the second MPI. The MPIs were normal in both studies in 399 (57%, Group 1), showed improvement in 94 (14%, Group 2, PDS 15% ± 16% vs 28% ± 18%, P < .001) and no change or worsening in 205 patients (29%, Group 3, 28% ± 17% vs 20% ± 17%, P < .001). The best outcomes were seen in Group 1 and the worst in Group 3 (log-rank P < .001). Similar trends were seen for the components of the primary outcome (P = .04 for death, P < .001 for MI, P < .001 for CR). In a Cox-regression model that adjusted for baseline factors including PDS and LVEF on initial MPI, the hazard ratios for primary outcome were 2.0 (P = .02) and 3.9 (P < .001) for Groups 2 and 3 compared to Group 1, respectively. In addition, an LVEF drop ≥5% was independently associated with the primary outcome (HR 1.5, P = .01). Changes in PDS and LVEF on serial MPIs provide incremental prognostic information to initial and follow-up MPI findings. Lack of

  13. Detection and severity classification of extracardiac interference in {sup 82}Rb PET myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Orton, Elizabeth J., E-mail: eorton@physics.carleton.ca; Kemp, Robert A. de; Glenn Wells, R. [Division of Cardiology, Department of Medicine, University of Ottawa Heart Institute, 40 Ruskin Street, Ottawa, Ontario K1Y 4W7 (Canada); Department of Physics, Carleton University, 1125 Colonel By Drive, Ottawa, Ontario K1S 5B6 (Canada); Al Harbi, Ibraheem [Division of Cardiology, Department of Medicine, University of Ottawa Heart Institute, 40 Ruskin Street, Ottawa, Ontario K1Y 4W7 (Canada); Department of Medicine (Cardiology), King Fahad Hospital, Medina 42351 (Saudi Arabia); Klein, Ran [Division of Cardiology, Department of Medicine, University of Ottawa Heart Institute, 40 Ruskin Street, Ottawa, Ontario K1Y 4W7 (Canada); Department of Biomedical Engineering, Carleton University, 1125 Colonel By Drive, Ottawa, Ontario K1S 5B6 (Canada); Beanlands, Rob S. B. [Division of Cardiology, Department of Medicine, University of Ottawa Heart Institute, 40 Ruskin Street, Ottawa, Ontario K1Y 4W7 (Canada)

    2014-10-15

    Purpose: Myocardial perfusion imaging (MPI) is used for diagnosis and prognosis of coronary artery disease. When MPI studies are performed with positron emission tomography (PET) and the radioactive tracer rubidium-82 chloride ({sup 82}Rb), a small but non-negligible fraction of studies (∼10%) suffer from extracardiac interference: high levels of tracer uptake in structures adjacent to the heart which mask the true cardiac tracer uptake. At present, there are no clinically available options for automated detection or correction of this problem. This work presents an algorithm that detects and classifies the severity of extracardiac interference in {sup 82}Rb PET MPI images and reports the accuracy and failure rate of the method. Methods: A set of 200 {sup 82}Rb PET MPI images were reviewed by a trained nuclear cardiologist and interference severity reported on a four-class scale, from absent to severe. An automated algorithm was developed that compares uptake at the external border of the myocardium to three thresholds, separating the four interference severity classes. A minimum area of interference was required, and the search region was limited to that facing the stomach wall and spleen. Maximizing concordance (Cohen’s Kappa) and minimizing failure rate for the set of 200 clinician-read images were used to find the optimal population-based constants defining search limit and minimum area parameters and the thresholds for the algorithm. Tenfold stratified cross-validation was used to find optimal thresholds and report accuracy measures (sensitivity, specificity, and Kappa). Results: The algorithm was capable of detecting interference with a mean [95% confidence interval] sensitivity/specificity/Kappa of 0.97 [0.94, 1.00]/0.82 [0.66, 0.98]/0.79 [0.65, 0.92], and a failure rate of 1.0% ± 0.2%. The four-class overall Kappa was 0.72 [0.64, 0.81]. Separation of mild versus moderate-or-greater interference was performed with good accuracy (sensitivity

  14. Comparative value of brain perfusion SPECT and [{sup 123}I]MIBG myocardial scintigraphy in distinguishing between dementia with Lewy bodies and Alzheimer's disease

    Energy Technology Data Exchange (ETDEWEB)

    Hanyu, Haruo; Shimizu, Soichiro; Hirao, Kentaro; Kanetaka, Hidekazu; Iwamoto, Toshihiko [Tokyo Medical University, Department of Geriatric Medicine, Tokyo (Japan); Chikamori, Taishiro; Usui, Yasuhiro; Yamashina, Akira [Tokyo Medical University, 2. Department of Internal Medicine, Tokyo (Japan); Koizumi, Kiyoshi; Abe, Kimihiko [Tokyo Medical University, Department of Radiology, Tokyo (Japan)

    2006-03-15

    Both decreased occipital perfusion on brain single-photon emission computed tomography (SPECT) and reduction in cardiac {sup 123}I-metaiodobenzylguanidine (MIBG) uptake are characteristic features of dementia with Lewy bodies (DLB), and potentially support the clinical diagnosis of DLB. The aim of this study was to compare the diagnostic value of these two methods for differentiation of DLB from Alzheimer's disease (AD). The study population comprised 19 patients with probable DLB and 39 patients with probable AD who underwent both SPECT with N-isopropyl-p-[{sup 123}I]iodoamphetamine and MIBG myocardial scintigraphy. Objective and quantitative measurement of perfusion in the medial occipital lobe, including the cuneus and lingual gyrus, was performed by the use of three-dimensional stereotactic surface projections. Medial occipital perfusion was significantly decreased in the DLB group compared with the AD group. The mean heart/mediastinum ratios of MIBG uptake were significantly lower in the DLB group than in the AD group. Although SPECT failed to demonstrate significant hypoperfusion in the medial occipital lobe in five patients with DLB, marked reduction of MIBG uptake was found in all patients with DLB. Receiver operating characteristic analysis revealed that MIBG myocardial scintigraphy enabled more accurate discrimination between DLB and AD than was possible with perfusion SPECT. MIBG myocardial scintigraphy may improve the sensitivity in the detection of DLB. In particular, this method may provide a powerful differential diagnostic tool when it is difficult to distinguish cases of DLB from AD using brain perfusion SPECT. (orig.)

  15. 3.0 T magnetic resonance myocardial perfusion imaging for semi-quantitative evaluation of coronary microvascular dysfunction in hypertrophic cardiomyopathy.

    Science.gov (United States)

    Yin, Liang; Xu, Hai-Yan; Zheng, Sui-Sheng; Zhu, Ying; Xiao, Jiang-Xi; Zhou, Wei; Yu, Si-Si; Gong, Liang-Geng

    2017-12-01

    This study aimed to assess coronary microvascular dysfunction (CMD) differences in hypertrophic cardiomyopathy (HCM) patients using cardiac magnetic resonance (CMR) first-pass perfusion and late gadolinium enhancement imaging. Forty-seven patients with HCM and twenty-one healthy volunteers underwent CMR at rest. Imaging protocols included short axis cine, first-pass myocardial perfusion, and late gadolinium enhancement (LGE). Left ventricular end-diastolic wall thickness (EDTH), LGE, time to peak (T peak ), maximal up-slope (Slope max ), and peak signal intensity (SI peak ) were assessed for each myocardial segment. The HCM myocardial segments were grouped by the degree of LGE and hypertrophy. T peak , SI peak , Slope max and EDTH in multiple groups were assessed and compared by ANOVA test/Kruskal-Wallis test. The Spearman correlation test was used to determine the relationships between EDTH, LGE and perfusion parameters (T peak , Slope max and SI peak ). Compared to control group segments, T peak increased while Slope max and SI peak decreased in non-LGE/non-hypertrophic segments and LGE/hypertrophic segments in the HCM group, while T peak increased more significantly in LGE/hypertrophic segments (all p hypertrophic segments of HCM patients, and it may be helpful in the early diagnosis of coronary microvascular dysfunction in HCM. This abnormal perfusion is associated with the severity of myocardial fibrosis and the degree of hypertrophy.

  16. Myocardial perfusion at rest in patients with Diabetes Mellitus Type 1 compared with healthy controls assessed with Multi Detector Computed Tomography

    DEFF Research Database (Denmark)

    Byrne, Christina; Jensen, Tonny; Hjortkjær, Henrik Øder

    2015-01-01

    years (p5,p95: 17,49). Median coronary calcium score was higher in T1DM patients (51 vs. 2, p=0.037) compared with controls. However, a similar frequency of >50% stenosis in one or more coronary arteries was found in T1DM patients and controls (18% vs. 14%, p=0.49). LV myocardial perfusion at rest (Myo...

  17. Preservation of Myocardial Perfusion and Function by Keeping Hypertrophied Heart Empty and Beating for Valve Surgery: An In Vivo MR Study of Pig Hearts.

    Science.gov (United States)

    Wang, Jian; Xiang, Bo; Deng, Jixian; Lin, Hung-Yu; Freed, Darren H; Arora, Rakesh C; Tian, Ganghong

    2017-01-01

    Objectives . Normothermic hyperkalemic cardioplegia arrest (NHCA) may not effectively preserve hypertrophied myocardium during open-heart surgery. Normothermic normokalemic beating perfusion (NNBP), keeping hearts empty-beating, was utilized as an alternative to evaluate its cardioprotective role. Materials and Methods . Twelve hypertrophied pig hearts at 58.6 ± 7.2 days after ascending aorta banding underwent NNBP and NHCA, respectively. Near infrared myocardial perfusion imaging with indocyanine green (ICG) was conducted to assess myocardial perfusion. Left ventricular (LV) contractile function was assessed by cine MRI. TUNEL staining and western blotting for caspase-3 cleavage and cardiac troponin I (cTnI) degradation were conducted in LV tissue samples. Results . Ascending aortic diameter was reduced by 52.7% ± 0.4% at approximately fifty-eight days after banding. LV wall thickness was significantly higher in aorta banding than in sham operation. Myocardial blood flow reflected by maximum ICG absorbance value was markedly higher in NNBP than in NHCA. The amount of apoptotic cardiomyocyte was significantly lower in NNBP than in NHCA. NNBP alleviated caspase-3 cleavage and cTnI degradation associated with NHCA. NNBP displayed a substantially increased postoperative ejection fraction relative to NHCA. Conclusions . NNBP was better than NHCA in enhancing myocardial perfusion, inhibiting cardiomyocyte apoptosis, and preserving LV contractile function for hypertrophied hearts.

  18. Myocardial perfusion abnormality and effects of Ca channel blockers on myocardial ischemia in patients with hypertrophic cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Taniguchi, Yoko [Kyoto Prefectural Univ. of Medicine (Japan)

    1997-03-01

    The purpose of this study was to investigate the frequency of myocardial ischemia and characteristic regions of myocardial hypoperfusion during stress in patients with hypertrophic cardiomyopathy. Furthermore, the effects of Ca channel blocker (verapamil, diltiazem) on myocardial ischemia were studied. One hundred patients with hypertrophic cardiomyopathy underwent exercise {sup 201}Tl SPECT. Sixty-eight patients had one or more {sup 201}Tl abnormalities. Of the 68 patients with {sup 201}Tl abnormalities, 56 had reversible {sup 201}Tl abnormalities and 12 had fixed defect. {sup 201}Tl abnormalities were frequently distributed in the anterior and posterior areas of junction between the ventricular septum and the free wall and the apex. Of the 56 patients with reversible {sup 201}Tl abnormalities, 40 patients underwent one more exercise {sup 201}Tl SPECT after 8 weeks of oral administration of verapamil or diltiazem. The {sup 201}Tl defect was visually scored as the defect score. Transient dilation index was calculated as an index of subendocardial ischemia. The mean defect score decreased significantly from 9.80{+-}4.35 to 5.50{+-}4.63 after verapamil and from 9.90{+-}5.17 to 5.50{+-}4.89 after diltiazem. Mean transient dilation index decreased from 1.20{+-}0.12 to 1.08{+-}0.09 after treatment with verapamil and from 1.16{+-}0.10 to 1.02{+-}0.09 after treatment with diltiazem. (K.H.)

  19. Long-term prognostic implications of myocardial perfusion imaging in octogenarians: an all-comer, cohort study

    Energy Technology Data Exchange (ETDEWEB)

    Katsikis, Athanasios [Onassis Cardiac Surgery Center, Nuclear Medicine Department, Athens (Greece); 401 General Military Hospital of Athens, Cardiology Department, Athens (Greece); Theodorakos, Athanasios; Manira, Vassiliki; Koutelou, Maria [Onassis Cardiac Surgery Center, Nuclear Medicine Department, Athens (Greece); Papaioannou, Spyridon [Athens Naval Hospital, Cardiology Department, Athens (Greece); Kolovou, Genovefa; Voudris, Vassilios [Onassis Cardiac Surgery Center, Cardiology Department, Athens (Greece)

    2017-08-15

    Evaluation of the long-term prognostic value of myocardial perfusion imaging (MPI) in octogenarians. Six hundred and twenty-nine octogenarians [51% previous myocardial infarction (MI) or revascularization] who underwent single-isotope MPI (78% {sup 201}Tl, 22% {sup 99m}Tc-tetrofosmin) with exercise (38% Bruce, 2% leg ergometry) or pharmacologic (58% adenosine, 2% dobutamine) stress were studied. All patients had LVEF determined by echocardiography within 1 month from MPI. Myocardial perfusion scoring was performed on a 17-segment LV-model with a 5-point grading system and three summed stress score (SSS)-based risk categories were formed [high-(SSS > 12), low-(SSS < 4), medium]. Prospective follow-up was performed to document all-cause (ACD), cardiac death (CD), MI, and revascularization. Revascularization was used to censor follow-up in survival analysis regarding ACD, CD, and CD/MI. For analysis of the CD, MI, or late revascularization (LR) composite, only revascularizations within 3 months from MPI (early revascularizations) were used for censoring. After 9.3 years there were 187 ACDs, 86 CDs, 28 MIs, and 77 revascularizations, including 28 early revascularizations. Adjusting for LVEF and stress-modality type, SSS was identified as an independent predictor of ACD [HR 1.03 (1.01-1.05)], CD [HR 1.05 (1.03-1.08)], CD,MI [HR 1.05 (1.02-1.07)], and CD,MI or LR [HR 1.05 (1.03-1.07)] (p ≤ 0.001 in all cases). Increased lung uptake had independent prognostic value only for the CD, MI, or LR end-point [HR 3 (1.2-7.7), p = 0.02]. Survival modeling demonstrated that LVEF and SSS, but not non-perfusion scintigraphic data provided incremental prognostic value over pre-test available clinical and historical information for all end-points. Differences between Kaplan-Meier survival curves of SSS-based risk groups were significant for all end-points (p < 0.001 in all cases). In octogenarians, MPI provides effective long-term risk stratification, regardless of stress type used

  20. High doses of vascular endothelial growth factor 165 safely, but transiently, improve myocardial perfusion in no-option ischemic disease.

    Science.gov (United States)

    Giusti, Imarilde I; Rodrigues, Clarissa G; Salles, Felipe B; Sant'Anna, Roberto T; Eibel, Bruna; Han, Sang W; Ludwig, Eduardo; Grossman, Gabriel; Prates, Paulo Roberto L; Sant'Anna, João Ricardo M; Filho, Guaracy F Teixeira; Markoski, Melissa M; Nesralla, Ivo A; Nardi, Nance B; Kalil, Renato A K

    2013-10-01

    Gene therapy can induce angiogenesis in ischemic tissues. The aim of this study was to assess safety, feasibility, and results, both clinical and on myocardial perfusion, of gene therapy in refractory angina. This was a phase I/II, prospective, temporal-controlled series, clinical trial. Thirteen patients were maintained for minimum 6 months under optimized clinical management, and then received intramyocardial injections of 2000 μg plasmid vascular endothelial growth factor 165 and were followed by single-photon emission computed tomography (SPECT), treadmill tests, Minnesota quality of life questionnaire (QOL), and New York Heart Association (NYHA) functional plus Canadian Cardiovascular Society (CCS) angina classifications. There were no deaths, early or late. During the optimized clinical treatment, we observed worsening of rest ischemia scores on SPECT (p<0.05). After treatment, there was a transitory increase in myocardial perfusion at the third-month SPECT under stress (pre-operative [pre-op] 18.38 ± 7.51 vs. 3 months 15.31 ± 7.30; p<0.01) and at the sixth month under rest (pre-op 13.23 ± 7.98 vs. 6 months: 16.92 ± 7.27; p<0.01). One year after, there were improvements in treadmill test steps (pre-op 2.46 ± 2.07 vs.12 months 4.15 ± 2.23; p<0.01) and oxygen consumption (pre-op 7.66 ± 4.47 vs.12 months 10.89 ± 4.65; p<0.05), QOL (pre-op 48.23 ± 18.35 vs.12 months 28.31 ± 18.14; p<0.01) scores, and CCS (pre-op 3 [3-3.5] vs.12 months 2 [1-2.5]; p<0.01) and NYHA (pre-op 3 [3-3] vs. 2 [2-2] vs. 12 months 2 [1-2]; p<0.01) classes. Gene therapy demonstrated to be feasible and safe in this advanced ischemic cardiomyopathy patient sample. There were improvements in clinical evaluation parameters, and a transitory increase in myocardial perfusion detectable by SPECT scintigraphy. NCT00744315 http://clinicaltrials.gov/

  1. Comparison between stress myocardial perfusion SPECT recorded with cadmium-zinc-telluride and Anger cameras in various study protocols

    Energy Technology Data Exchange (ETDEWEB)

    Verger, Antoine; Karcher, Gilles [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); INSERM U947, Nancy (France); Nancyclotep Experimental Imaging Platform, Nancy (France); Djaballah, Wassila [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); INSERM U947, Nancy (France); Fourquet, Nicolas [Clinique Pasteur, Toulouse (France); Rouzet, Francois; Le Guludec, Dominique [AP-HP, Hopital Bichat, Department of Nuclear Medicine, Paris (France); INSERM U 773 Inserm and Denis Diderot University, Paris (France); Koehl, Gregoire; Roch, Veronique [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); Nancyclotep Experimental Imaging Platform, Nancy (France); Imbert, Laetitia [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); Nancyclotep Experimental Imaging Platform, Nancy (France); Centre Alexis Vautrin, Department of Radiotherapy, Vandoeuvre (France); Poussier, Sylvain [INSERM U947, Nancy (France); Nancyclotep Experimental Imaging Platform, Nancy (France); Fay, Renaud [INSERM, Centre d' Investigation Clinique CIC-P 9501, Nancy (France); Marie, Pierre-Yves [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); Nancyclotep Experimental Imaging Platform, Nancy (France); INSERM U961, Nancy (France); Hopital de Brabois, CHU-Nancy, Medecine Nucleaire, Vandoeuvre-les-Nancy (France)

    2013-03-15

    The results of stress myocardial perfusion SPECT could be enhanced by new cadmium-zinc-telluride (CZT) cameras, although differences compared to the results with conventional Anger cameras remain poorly known for most study protocols. This study was aimed at comparing the results of CZT and Anger SPECT according to various study protocols while taking into account the influence of obesity. The study population, which was from three different institutions equipped with identical CZT cameras, comprised 276 patients referred for study using protocols involving {sup 201}Tl (n = 120) or {sup 99m}Tc-sestamibi injected at low dose at stress ({sup 99m}Tc-Low; stress/rest 1-day protocol; n = 110) or at high dose at stress ({sup 99m}Tc-High; rest/stress 1-day or 2-day protocol; n = 46). Each Anger SPECT scan was followed by a high-speed CZT SPECT scan (2 to 4 min). Agreement rates between CZT and Anger SPECT were good irrespective of the study protocol (for abnormal SPECT, {sup 201}Tl 92 %, {sup 99m}Tc-Low 86 %, {sup 99m}Tc-High 98 %), although quality scores were much higher for CZT SPECT with all study protocols. Overall correlations were high for the extent of myocardial infarction (r = 0.80) and a little lower for ischaemic areas (r = 0.72), the latter being larger on Anger SPECT (p < 0.001). This larger extent was mainly observed in 50 obese patients who were in the {sup 201}Tl or {sup 99m}Tc-Low group and in whom stress myocardial counts were particularly low with Anger SPECT (228 {+-} 101 kcounts) and dramatically enhanced with CZT SPECT (+279 {+-} 251 %). Concordance between the results of CZT and Anger SPECT is good regardless of study protocol and especially when excluding obese patients who have low-count Anger SPECT and for whom myocardial counts are dramatically enhanced on CZT SPECT. (orig.)

  2. Septal and Anterior Reverse Mismatch of Myocardial Perfusion and Metabolism in Patients With Coronary Artery Disease and Left Bundle Branch Block

    Science.gov (United States)

    Wang